Sample records for diameter body section

  1. Apparatus for measuring surface particulate contamination

    DOEpatents

    Woodmansee, Donald E.

    2002-01-01

    An apparatus for measuring surface particulate contamination includes a tool for collecting a contamination sample from a target surface, a mask having an opening of known area formed therein for defining the target surface, and a flexible connector connecting the tool to the mask. The tool includes a body portion having a large diameter section defining a surface and a small diameter section extending from the large diameter section. A particulate collector is removably mounted on the surface of the large diameter section for collecting the contaminants. The tool further includes a spindle extending from the small diameter section and a spool slidingly mounted on the spindle. A spring is disposed between the small diameter section and the spool for biasing the spool away from the small diameter section. An indicator is provided on the spindle so as to be revealed when the spool is pressed downward to compress the spring.

  2. 21 CFR 1020.33 - Computed tomography (CT) equipment.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... opening where insertion of any part of the human body into the primary beam is possible. (2) For systems... Section 1020.33 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... diameters of 32.0 centimeters for testing any CT system designed to image any section of the body (whole...

  3. 21 CFR 1020.33 - Computed tomography (CT) equipment.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... opening where insertion of any part of the human body into the primary beam is possible. (2) For systems... Section 1020.33 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... diameters of 32.0 centimeters for testing any CT system designed to image any section of the body (whole...

  4. Elastomeric member for energy storage device

    DOEpatents

    Hoppie, Lyle O.; Chute, Richard

    1985-01-01

    An energy storage device (10) is disclosed consisting of a stretched elongated elastomeric member (16), disposed within a tubular housing (14), which elastomeric member (16) is adapted to be torsionally stressed to store energy. The elastomeric member (16) is configured in the relaxed state with a uniform diameter body section, transition end sections, and is attached to rigid end piece assemblies (22, 24) of a lesser diameter. The profile and deflection characteristic of the transition sections (76, 78) are such that upon stretching of the member, a substantially uniform diameter assembly results to minimize the required volume of the surrounding housing (14). During manufacture, woven wire mesh sleeves (26, 28) are forced against a forming surface and bonded to the associated transition section (76, 78) to provide the correct profile and helix angle. Each sleeve (26, 28) contracts with the contraction of the associated transition section to maintain the bond therebetween.

  5. Elastomeric member and method of manufacture therefor

    DOEpatents

    Hoppie, L.O.

    1985-12-10

    An energy storage device is disclosed consisting of a stretched elongated elastomeric member disposed within a tubular housing, which elastomeric member is adapted to be torsionally stressed to store energy. The elastomeric member is configured in the relaxed state with a uniform diameter body section, and transition end sections, attached to rigid end piece assemblies of a lesser diameter. The profile and deflection characteristic of the transition sections are such that upon stretching of the elastomeric member, a substantially uniform diameter assembly results, to minimize the required volume of the surrounding housing. Each of the transition sections are received within and bonded to a woven wire mesh sleeve having helical windings at a particular helix angle to control the deflection of the transition section. Each sleeve also contracts with the contraction of the associated transition section to maintain the bond therebetween. During manufacture, the sleeves are forced against a forming surface and bonded to the associated transition section to provide the correct profile and helix angle. 12 figs.

  6. Elastomeric member

    DOEpatents

    Hoppie, L.O.

    1985-07-30

    An energy storage device is disclosed consisting of a stretched elongated elastomeric member disposed within a tubular housing, which elastomeric member is adapted to be torsionally stressed to store energy. The elastomeric member is configured in the relaxed state with a uniform diameter body section, and transition end sections, attached to rigid end piece assemblies of a lesser diameter. The profile and deflection characteristic of the transition sections are such that upon stretching of the elastomeric member, a substantially uniform diameter assembly results, to minimize the required volume of the surrounding housing. Each of the transition sections are received within and bonded to a woven wire mesh sleeve having helical windings at a particular helix angle to control the deflection of the transition section. Each sleeve also contracts with the contraction of the associated transition section to maintain the bond there between. During manufacture, the sleeves are forced against a forming surface and bonded to the associated transition section to provide the correct profile and helix angle. 12 figs.

  7. Lower airway dimensions in pediatric patients-A computed tomography study.

    PubMed

    Szelloe, Patricia; Weiss, Markus; Schraner, Thomas; Dave, Mital H

    2017-10-01

    The aim of this study was to obtain lower airway dimensions in children by means of computed tomography (CT). Chest CT scans from 195 pediatric patients (118 boys/77 girls) aged 0.04-15.99 years were analyzed. Tracheal and bronchial lengths, anterior-posterior and lateral diameters, as well as cross-sectional area were assessed at the following levels: mid trachea, right proximal and distal bronchus, proximal bronchus intermedius, and left proximal and distal bronchus. Mediastinal angles of tracheal bifurcation were measured. Data were analyzed by means of linear and polynomial regression plots. The strongest correlations were found between tracheal and bronchial diameters and age as well as between tracheal and bronchial lengths and body length. All measured airway parameters correlated poorly to body weight. Bronchial angles revealed no association with patient's age, body length, or weight. This comprehensive anatomical database of lower airway dimensions demonstrates that tracheal and bronchial diameters correlate better to age, and that tracheal and bronchial length correlate better to body length. All measured airway parameters correlated poorly to body weight. © 2017 John Wiley & Sons Ltd.

  8. Elastomeric member and method of manufacture therefor

    DOEpatents

    Hoppie, Lyle O.

    1985-01-01

    An energy storage device (10) is disclosed consisting of a stretched elongated elastomeric member (16) disposed within a tubular housing (14), which elastomeric member (16) is adapted to be torsionally stressed to store energy. The elastomeric member (16) is configured in the relaxed state with a uniform diameter body section (74), and transition end sections (76, 78), attached to rigid end piece assemblies (22, 24) of a lesser diameter. The profile and deflection characteristic of the transition sections (76, 78) are such that upon stretching of the elastomeric member (16), a substantially uniform diameter assembly results, to minimize the required volume of the surrounding housing (14). Each of the transition sections (76, 78) are received within and bonded to a woven wire mesh sleeve (26, 28) having helical windings at a particular helix angle to control the deflection of the transition section. Each sleeve (26, 28) also contracts with the contraction of the associated transition section to maintain the bond therebetween. During manufacture, the sleeves (26, 28) are forced against a forming surface and bonded to the associated transition section (76, 78) to provide the correct profile and helix angle.

  9. Elastomeric member

    DOEpatents

    Hoppie, Lyle O.

    1985-01-01

    An energy storage device (10) is disclosed consisting of a stretched elongated elastomeric member (16) disposed within a tubular housing (14), which elastomeric member (16) is adapted to be torsionally stressed to store energy. The elastomeric member (16) is configured in the relaxed state with a uniform diameter body section (74), and transition end sections (76, 78), attached to rigid end piece assemblies (22, 24) of a lesser diameter. The profile and deflection characteristic of the transition sections (76, 78) are such that upon stretching of the elastomeric member (16), a substantially uniform diameter assembly results, to minimize the required volume of the surrounding housing (14). Each of the transition sections (76, 78) are received within and bonded to a woven wire mesh sleeve (26, 28) having helical windings at a particular helix angle to control the deflection of the transition section. Each sleeve (26, 28) also contracts with the contraction of the associated transition section to maintain the bond therebetween. During manufacture, the sleeves (26, 28) are forced against a forming surface and bonded to the associated transition section (76, 78) to provide the correct profile and helix angle.

  10. Stable density stratification solar pond

    NASA Technical Reports Server (NTRS)

    Lansing, F. L. (Inventor)

    1985-01-01

    A stable density-stratification solar pond for use in the collection and storage of solar thermal energy including a container having a first section characterized by an internal wall of a substantially cylindrical configuration and a second section having an internal wall of a substantially truncated conical configuration surmounting the first section in coaxial alignment therewith, the second section of said container being characterized by a base of a diameter substantially equal to the diameter of the first section and a truncated apex defining a solar energy acceptance opening is discussed. A body of immiscible liquids is disposed within the container and comprises a lower portion substantially filling the first section of the container and an upper portion substantially filling the second section of the container, said lower portion being an aqueous based liquid of a darker color than the upper portion and of a greater density. A protective cover plate is removably provided for covering the acceptance opening.

  11. Congenital lumbar spinal stenosis: a prospective, control-matched, cohort radiographic analysis.

    PubMed

    Singh, Kern; Samartzis, Dino; Vaccaro, Alexander R; Nassr, Ahmad; Andersson, Gunnar B; Yoon, S Tim; Phillips, Frank M; Goldberg, Edward J; An, Howard S

    2005-01-01

    Degenerative lumbar spinal stenosis manifests primarily after the sixth decade of life as a result of facet hypertrophy and degenerative disc disease. Congenital stenosis, on the other hand, presents earlier in age with similar clinical findings but with multilevel involvement and fewer degenerative changes. These patients may have subtle anatomic variations of the lumbar spine that may increase the likelihood of thecal sac compression. However, to the authors' knowledge, no quantitative studies have addressed various radiographic parameters of symptomatic, congenitally stenotic individuals to normal subjects. To radiographically quantify and compare the anatomy of the lumbar spine in symptomatic, congenitally stenotic individuals to age- and sex-matched, asymptomatic, nonstenotic controlled individuals. A prospective, control-matched, cohort radiographic analysis. Axial and sagittal magnetic resonance imaging (MRI) and lateral, lumbar, plain radiographs of 20 surgically treated patients who were given a clinical diagnosis of congenital lumbar stenosis by the senior author were randomized with images of 20, asymptomatic age- and sex-matched subjects. MRIs and lateral, lumbar, plain radiographs were independently quantitatively assessed by two individuals. Measurements obtained from the axial MRIs included: midline anterior-posterior (AP) vertebral body diameter, vertebral body width, midline AP canal diameter, canal width, spinal canal cross-sectional area, pedicle length, and pedicle width. From the sagittal MRIs, the following measurements were calculated: AP vertebral body diameter, vertebral body height, and AP canal diameter at the mid-vertebral level. On the lateral, lumbar, plain radiograph (L3 level), the AP diameters of the vertebral body spinal canal were measured. The images of these 40 individuals were then randomized and distributed in a blinded fashion to five separate spine surgeons who graded the presence and severity of congenital stenosis utilizing a five-tier scale. Images consisting of 15 symptomatic individuals, graded definitely congenitally stenotic (mean age, 51.7 years; range, 43-65 years), and 15 asymptomatic individuals, graded definitely not stenotic (mean age, 50.7 years; range, 41-55 years), were age- and sex-matched and included for further review. From these 30 patients, a lateral, lumbar, plain radiograph and axial and sagittal MRIs (T1/T2 weighted) from L2-L5 were quantitatively analyzed. Rater reliability was assessed by Kappa coefficient testing. The cross-sectional area of the canal was significantly smaller in the congenitally stenotic patients at all lumbar levels measured (L2: 176 mm(2) vs. 259 mm(2), L3: 177 mm(2) vs. 275 mm(2), L4: 183 mm(2) vs. 283 mm(2), L5: 213 mm(2) vs. 323 mm(2), p<.05). Pedicle length was markedly shorter in the stenosis group at each lumbar level (L2: 5.9 mm vs. 8.9 mm, L3: 6.0 mm vs. 8.8 mm, L4: 6.5 mm vs. 9.2 mm, L5: 5.8 mm vs. 9.1 mm, p<.05). Furthermore, midline, axial AP canal diameter, vertebral body width, and sagittal AP canal diameter were all significantly smaller than the control patients (p<.05). A ratio of the AP diameter of the pedicle length to the vertebral body was also noted to be statistically significant on both the lateral plain radiographs (L3: 0.426 vs. 0.704) and sagittal MRI (L2: 0.343 vs. 0.461, L3: 0.361 vs. 0.461, L4: 0.362 vs. 0.481, L5: 0.354 vs. 0.452, p<.05). No difference was noted comparing the AP diameter of the vertebral body (axial and sagittal images), vertebral body height, canal width, and pedicle width. Kappa testing coefficient indicated a strong rater reliability (k=0.81, 95% confidence interval: 0.62-0.94). Congenital lumbar stenosis has not been clearly defined radiographically. Clinically, congenitally stenotic patients present at a younger age with fewer degenerative changes and multiple levels of involvement. Radiographically, these patients have a shorter pedicular length and as a result a smaller cross-sectional spinal canal area (mean critical values of 6.5 mm and 213 mm(2) were observed, respectively). The mean critical ratios were 0.43 (2:1 AP vertebral body: pedicle length) on the lateral lumbar radiograph and 0.36 on the sagittal MRI. The altered canal anatomy resulting from a decreased pedicle length may anatomically predispose these patients to earlier complaints of symptomatic neurogenic claudication. Identification of the presence of congenital stenosis should increase the treating surgeon's awareness of the potential need for multilevel treatment.

  12. A High-Resolution Endoscope of Small Diameter Using Electromagnetically Vibration of Single Fiber

    NASA Astrophysics Data System (ADS)

    Matsunaga, Tadao; Hino, Ryunosuke; Makishi, Wataru; Esashi, Masayoshi; Haga, Yoichi

    For high resolution visual inspection in the narrow space of the human body, small diameter endoscope has been developed which utilize electromagnetically vibration of single fiber. Thin endoscopes are effective for inspection in the narrow space of the human body, for example, in the blood vessel, lactiferous duct for detection infiltration of breast cancer, and periodontal gap between gingiva and tooth. This endoscope consists of single optical fiber and photofabricated driving coils. A collimator lens and a cylindrical permanent magnet are fixed on the optical fiber, and the tilted driving coils have been patterned on a 1.08 mm outer diameter thin tube. The fiber is positioned at the center of the tube which is patterned the coils. When an electrical alternating current at the resonance frequency is supplied to the coils, the permanent magnet which is fixed to the fiber is vibrated electromagnetically and scanned one or two dimensionally. This paper reports small diameter endoscope by using electromagnetically vibration of single fiber. Optical coherence tomography imaging has also been carried out with the fabricated endoscope and cross-section image of sub-surface skin of thumb was observed.

  13. Determination of Shapes of Boattail Bodies of Revolution for Minimum Wave Drag

    NASA Technical Reports Server (NTRS)

    Adams, Mac C.

    1951-01-01

    By use of an approximate equation for the wave drag of slender bodies of revolution in a supersonic flow field, the optimum shapes of certain boattail bodies are determined for minimum wave drag. The properties of three specific families of bodies are determined, the first family consisting of bodies having a given length and base area and a contour passing through a prescribed point between the nose and base, the second family having fixed length, base area, and maximum area, and the third family having given length, volume, and base area. The method presented is easily generalized to determine minimum-wave-drag profile shapes which have contours that must pass through any prescribed number of points. According to linearized theory, the optimum profiles are found to have infinite slope at the nose but zero radius of curvature so that the bodies appear to have pointed noses, a zero slope at the body base, and no variation of wave drag with Mach number. For those bodies having a specified intermediate.diameter (that is, location and magnitude given), the maximum body diameter is shown to be larger, in general, than the specified diameter. It is also shown that, for bodies having a specified maximum diameter, the location of the maximum diameter is not arbitrary but is determined from the ratio of base diameter to maximum diameter.

  14. Digital image analysis of ossification centers in the axial dens and body in the human fetus.

    PubMed

    Baumgart, Mariusz; Wiśniewski, Marcin; Grzonkowska, Magdalena; Małkowski, Bogdan; Badura, Mateusz; Dąbrowska, Maria; Szpinda, Michał

    2016-12-01

    The detailed understanding of the anatomy and timing of ossification centers is indispensable in both determining the fetal stage and maturity and for detecting congenital disorders. This study was performed to quantitatively examine the odontoid and body ossification centers in the axis with respect to their linear, planar and volumetric parameters. Using the methods of CT, digital image analysis and statistics, the size of the odontoid and body ossification centers in the axis in 55 spontaneously aborted human fetuses aged 17-30 weeks was studied. With no sex difference, the best fit growth dynamics for odontoid and body ossification centers of the axis were, respectively, as follows: for transverse diameter y = -10.752 + 4.276 × ln(age) ± 0.335 and y = -10.578 + 4.265 × ln(age) ± 0.338, for sagittal diameter y = -4.329 + 2.010 × ln(age) ± 0.182 and y = -3.934 + 1.930 × ln(age) ± 0.182, for cross-sectional area y = -7.102 + 0.520 × age ± 0.724 and y = -7.002 + 0.521 × age ± 0.726, and for volume y = -37.021 + 14.014 × ln(age) ± 1.091 and y = -37.425 + 14.197 × ln(age) ± 1.109. With no sex differences, the odontoid and body ossification centers of the axis grow logarithmically in transverse and sagittal diameters, and in volume, while proportionately in cross-sectional area. Our specific-age reference data for the odontoid and body ossification centers of the axis may be relevant for determining the fetal stage and maturity and for in utero three-dimensional sonographic detecting segmentation anomalies of the axis.

  15. Anatomic characteristics of ruptured abdominal aortic aneurysm on conventional CT scans: Implications for rupture risk.

    PubMed

    Fillinger, Mark F; Racusin, Jessica; Baker, Robert K; Cronenwett, Jack L; Teutelink, Arno; Schermerhorn, Marc L; Zwolak, Robert M; Powell, Richard J; Walsh, Daniel B; Rzucidlo, Eva M

    2004-06-01

    The purpose of this study was to analyze anatomic characteristics of patients with ruptured abdominal aortic aneurysms (AAAs), with conventional two-dimensional computed tomography (CT), including comparison with control subjects matched for age, gender, and size. Records were reviewed to identify all CT scans obtained at Dartmouth-Hitchcock Medical Center or referring hospitals before emergency AAA repair performed because of rupture or acute severe pain (RUP group). CT scans obtained before elective AAA repair (ELEC group) were reviewed for age and gender match with patients in the RUP group. More than 40 variables were measured on each CT scan. Aneurysm diameter matching was achieved by consecutively deleting the largest RUP scan and the smallest ELEC scan to prevent bias. CT scans were analyzed for 259 patients with AAAs: 122 RUP and 137 ELEC. Patients were well matched for age, gender, and other demographic variables or risk factors. Maximum AAA diameter was significantly different in comparisons of all patients (RUP, 6.5 +/- 2 cm vs ELEC, 5.6 +/- 1 cm; P <.0001), and mean diameter of ruptured AAAs was 5 mm smaller in female patients (6.1 +/- 2 cm vs 6.6 +/- 2 cm; P =.007). Two hundred patients were matched for diameter, gender, and age (100 from each group; maximum AAA diameter, 6.0 +/- 1 cm vs 6.0 +/- 1 cm). Analysis of diameter-matched AAAs indicated that most variables were statistically similar in the two groups, including infrarenal neck length (17 +/- 1 mm vs 19 +/- 1 mm; P =.3), maximum thrombus thickness (25 +/- 1 mm vs 23 +/- 1 mm, P =.4), and indices of body habitus, such as [(maximum AAA diameter)/(normal suprarenal aorta diameter)] or [(maximum AAA diameter)/(L3 transverse diameter)]. Multivariate analysis controlling for gender indicated that the most significant variables for rupture were aortic tortuosity (odds ratio [OR] 3.3, indicating greater risk with no or mild tortuosity), diameter asymmetry (OR, 3.2 for a 1-cm difference in major-minor axis), and current smoking (OR, 2.7, with the greater risk in current smokers). When matched for age, gender, and diameter, ruptured AAAs tend to be less tortuous, yet have greater cross-sectional diameter asymmetry. On conventional two-dimensional CT axial sections, it appears that when diameter asymmetry is associated with low aortic tortuosity, the larger diameter on axial sections more accurately reflects rupture risk, and when diameter asymmetry is associated with moderate or severe aortic tortuosity, the smaller diameter on axial sections more accurately reflects rupture risk. Current smoking is significantly associated with rupture, even when controlling for gender and AAA anatomy.

  16. Full-Scale Tests of Several Propellers Equipped with Spinners, Cuffs, Airfoil and Round Shanks, and NACA 16-Series Sections, Special Report

    NASA Technical Reports Server (NTRS)

    Biermann, David; Hartman, Edwin P.; Pepper, Edward

    1940-01-01

    Wind-tunnel tests of several propeller, cuff, and spinner combinations were conducted in the 20 foot propeller-research tunnel. Three propellers, which ranged in diameter from 8.4 to 11.25 feet, were tested at the front end of a streamline body incorporating spinners of two diameters. The tests covered a blade angle range from 20 deg to 65 deg. The effect of spinner diameter and propeller cuffs on the characteristics of one propeller was determined. Test were also conducted using a propeller which incorporated aerodynamically good shank sections and using one which incorporated the NACA 16 series sections for the outer 20 percent of the blades. Compressibility effects were not measured, owing to the low testing speeds. The results indicated that a conventional propeller was slightly more efficient when tested in conjunction with a 28 inch diameter spinner than with a 23 inch spinner, and that cuffs increased the efficiency as well as the power absorption characteristics. A propeller having good aerodynamic shanks was found to be definitely superior from the efficiency standpoint to a conventional round-shank propeller with or without cuffs; this propeller would probably be considered structurally impracticable, however. The propeller incorporating the NACA 16 series sections at the tims were found to have a slightly higher efficiency than a conventional propeller; the take-off characteristics appeared to be equally good. The effects noted above probably would be accentuated at helical speeds at which compressibility effects would enter.

  17. Stereological study of rat spleen following acute ethanol treatment.

    PubMed

    Budec, M; Milićević, Z; Koko, V

    2000-05-01

    To investigate the acute effect of ethanol (4 g/kg, i.p.) on spleen adult female Wistar rats were treated intraperitoneally with: a) ethanol (4 g/kg body wt), b) naltrexone (5 mg/kg body wt) followed 45 minutes later by ethanol (4 g/kg body wt) and c) naltrexone (5 mg/kg body wt) alone. Untreated and saline-treated rats were used as controls. Twenty hours after the ethanol treatment the animals were sacrificed and the spleens were removed. A piece of tissue from the central part of each organ was fixed in Bouin's solution. Paraffin sections were stained with hematoxylin-eosin and analysed using stereological measurements. The volume densities of the following tissue compartments: red pulp, white pulp (divided in follicles, periarterioral lymphatic sheath and marginal zone) and the connective tissue were determined. Stereological analysis also included parameters of follicles: the areal numerical density (the number of follicles per 1 mm2 of tissue section), the numerical density (the number of follicles per mm3 of tissue) and the mean follicle diameter. The immunoarchitecture of the spleen was preserved following acute ethanol treatment. Unlike other parameters that were unaffected, ethanol evoked a decrease in both volume density of follicle and the mean follicle diameter. Naltrexone pretreatment had no influence on ethanol-induced changes. The data obtained indicate that a single dose of ethanol has a profound effect on rat spleen affecting the follicles, but the mechanism of its action remains to be elucidated.

  18. Tourniquet application after local forearm warming to improve venodilation for peripheral intravenous cannulation in young and middle-aged adults: A single-blind prospective randomized controlled trial.

    PubMed

    Yamagami, Yuki; Tomita, Kohei; Tsujimoto, Tomomi; Inoue, Tomoko

    2017-07-01

    Local forearm warming before tourniquet application is often used to promote venodilation for peripheral intravenous cannulation; however, few studies have compared the effect of tourniquet application with and without local warming on vein size. To evaluate the effectiveness of tourniquet application after local forearm warming with that of tourniquet application alone in young and middle-aged adults. A single-blind, prospective, parallel group, randomized controlled trial. A national university in Japan. Seventy-two volunteers aged 20-64 years. Participants were randomly allocated to one of two groups: tourniquet application for 30s after forearm application of a heat pack warmed to 40°C±2°C for 15min (active warming group; n=36) or tourniquet application for 30s after applying a non-warmed heat pack for 15min (passive warming group; n=36). The primary outcomes were vein cross-sectional area on the forearm, measured after the intervention by blinded research assistants using ultrasound. Secondary outcomes were shortest diameter, and longest diameter of vein on the forearm, forearm skin temperature, body temperature, pulse, systolic blood pressure, and diastolic blood pressure. All outcomes were assessed at the same site before and immediately after the intervention, once per participant. Vein cross-sectional area, shortest vein diameter, and longest vein diameter were significantly increased in the active warming group compared with the passive warming group (p <0.01). Tourniquet application after local warming was superior to tourniquet application alone in increasing vein cross-sectional, shortest diameter, and longest diameter (between-group differences of 2.2mm 2 , 0.5mm, and 0.5mm, respectively), and in raising skin temperature (between-group difference: 5.2°C). However, there were no significant differences in body temperature, pulse, or systolic or diastolic blood pressure between the groups. There were no adverse events associated with either intervention. Tourniquet application after local warming was associated with increased forearm vein size when compared with tourniquet application alone, and was demonstrated as being safe. Thus, with demonstrable effects on vein size, we recommend local warming before tourniquet application as a safe and effective technique for improving venodilation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  19. 78 FR 15835 - Requirements Pertaining to Third Party Conformity Assessment Bodies

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-03-12

    ... parties. In that case, the laboratory is considered ``firewalled.'' Similarly, section 14(f)(2)(B) of the..., ASTM F2853-10, requires only one measurement when used to determine the lead content of a paint sample... heterogeneity effect: * * * an 8 mm diameter x-ray surface shot (HHXRF),\\2\\ with a scatter that widens in three...

  20. Arecibo Radar Observation of Near-Earth Asteroids: Expanded Sample Size, Determination of Radar Albedos, and Measurements of Polarization Ratios

    NASA Astrophysics Data System (ADS)

    Lejoly, Cassandra; Howell, Ellen S.; Taylor, Patrick A.; Springmann, Alessondra; Virkki, Anne; Nolan, Michael C.; Rivera-Valentin, Edgard G.; Benner, Lance A. M.; Brozovic, Marina; Giorgini, Jon D.

    2017-10-01

    The Near-Earth Asteroid (NEA) population ranges in size from a few meters to more than 10 kilometers. NEAs have a wide variety of taxonomic classes, surface features, and shapes, including spheroids, binary objects, contact binaries, elongated, as well as irregular bodies. Using the Arecibo Observatory planetary radar system, we have measured apparent rotation rate, radar reflectivity, apparent diameter, and radar albedos for over 350 NEAs. The radar albedo is defined as the radar cross-section divided by the geometric cross-section. If a shape model is available, the actual cross-section is known at the time of the observation. Otherwise we derive a geometric cross-section from a measured diameter. When radar imaging is available, the diameter was measured from the apparent range depth. However, when radar imaging was not available, we used the continuous wave (CW) bandwidth radar measurements in conjunction with the period of the object. The CW bandwidth provides apparent rotation rate, which, given an independent rotation measurement, such as from lightcurves, constrains the size of the object. We assumed an equatorial view unless we knew the pole orientation, which gives a lower limit on the diameter. The CW also provides the polarization ratio, which is the ratio of the SC and OC cross-sections.We confirm the trend found by Benner et al. (2008) that taxonomic types E and V have very high polarization ratios. We have obtained a larger sample and can analyze additional trends with spin, size, rotation rate, taxonomic class, polarization ratio, and radar albedo to interpret the origin of the NEAs and their dynamical processes. The distribution of radar albedo and polarization ratio at the smallest diameters (≤50 m) differs from the distribution of larger objects (>50 m), although the sample size is limited. Additionally, we find more moderate radar albedos for the smallest NEAs when compared to those with diameters 50-150 m. We will present additional trends we find in this data set.

  1. Central obesity is an independent predictor of erectile dysfunction in older men.

    PubMed

    Riedner, Charles Edison; Rhoden, Ernani Luis; Ribeiro, Eduardo Porto; Fuchs, Sandra Costa

    2006-10-01

    There is a growing body of evidence in the literature correlating erectile dysfunction to obesity. We investigated the correlation of different anthropometric indexes of central obesity to erectile dysfunction. A cross-sectional study was performed including 256 consecutive men 40 years old or older. All men completed the International Index of Erectile Function, and were evaluated routinely with a clinical history, physical examination and blood analysis for fasting serum glucose, lipid profile and serum testosterone. Anthropometric measures included body mass index, waist circumference, sagittal abdominal diameter, maximal abdominal circumference, and waist-hip, waist-thigh, waist-height, sagittal abdominal diameter-thigh and sagittal abdominal diameter-height indexes. In men 40 to 60 years old the different anthropometric indexes of central obesity were not correlated with the presence of erectile dysfunction (p > 0.05). Men older than 60 years (41%, range 61 to 81) demonstrated an association among erectile dysfunction and waist-hip index (p = 0.04), waist-thigh index (p = 0.02), sagittal abdominal diameter (p = 0.03), sagittal abdominal diameter-height index (p = 0.02) and maximal abdominal circumference (p = 0.04). After logistic regression analysis an independent effect on the presence of erectile dysfunction was observed for waist-hip index (OR 8.56, 95% CI 1.44-50.73), sagittal abdominal diameter (OR 7.87, 95% CI 1.24-49.75), sagittal abdominal diameter-height index (OR 14.21, 95% CI 1.11-182.32), maximum abdominal circumference (OR 11.72, 95% CI 1.73-79.18) and waist circumference (OR 19.37, 95% CI 1.15-326.55). This study suggests that central obesity, assessed by several anthropometric indicators, is associated to the presence of erectile dysfunction in men older than 60 years. Sagittal abdominal diameter, sagittal abdominal diameter-height index, maximum abdominal circumference, waist circumference and waist-hip index were useful indicators to predict the presence of erectile dysfunction.

  2. TH-C-18A-12: Evaluation of the Impact of Body Size and Tube Output Limits in the Optimization of Fast Scanning with High-Pitch Dual Source CT

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ramirez Giraldo, J; Mileto, A.; Hurwitz, L.

    2014-06-15

    Purpose: To evaluate the impact of body size and tube power limits in the optimization of fast scanning with high-pitch dual source CT (DSCT). Methods: A previously validated MERCURY phantom, made of polyethylene, with circular cross-section of diameters 16, 23, 30 and 37cm, and connected through tapered sections, was scanned using a second generation DSCT system. The DSCT operates with two independently controlled x-ray tube generators offering up to 200 kW power reserve (100 kW per tube). The entire length of the phantom (42cm) was scanned with two protocols using: A)Standard single-source CT (SSCT) protocol with pitch of 0.8, andmore » B) DSCT protocol with high-pitch values ranging from 1.6 to 3.2 (0.2 steps). All scans used 120 kVp with 150 quality reference mAs using automatic exposure control. Scanner radiation output (CTDIvol) and effective mAs values were extracted retrospectively from DICOM files for each slice. Image noise was recorded. All variables were assessed relative to phantom diameter. Results: With standard-pitch SSCT, the scanner radiation output (and tube-current) were progressively adapted with increasing size, from 6 mGy (120 mAs) up to 15 mGy (270 mAs) from the thinnest (16cm) to the thickest diameter (37 cm), respectively. By comparison, using high-pitch (3.2), the scanner output was bounded at about 8 mGy (140 mAs), independent of phantom diameter. Although relative to standard-pitch, the high-pitch led to lower radiation output for the same scan, the image noise was higher, particularly for larger diameters. To match the radiation output adaptation of standard-pitch, a high-pitch mode of 1.6 was needed, with the advantage of scanning twice as fast. Conclusion: To maximize the benefits of fast scanning with high-pitch DSCT, the body size and tube power limits of the system need to be considered such that a good balance between speed of acquisition and image quality are warranted. JCRG is an employee of Siemens Medical Solutions USA Inc.« less

  3. Longitudinal aerodynamic performance of a series of power-law and minimum wave drag bodies at Mach 6 and several Reynolds numbers

    NASA Technical Reports Server (NTRS)

    Ashby, G. C., Jr.

    1974-01-01

    Experimental data have been obtained for two series of bodies at Mach 6 and Reynolds numbers, based on model length, from 1.4 million to 9.5 million. One series consisted of axisymmetric power-law bodies geometrically constrained for constant length and base diameter with values of the exponent n of 0.25, 0.5, 0.6, 0.667, 0.75, and 1.0. The other series consisted of positively and negatively cambered bodies of polygonal cross section, each having a constant longitudinal area distribution conforming to that required for minimizing zero-lift wave drag at hypersonic speeds under the geometric constraints of given length and volume. At the highest Reynolds number, the power-law body for minimum drag is blunter (exponent n lower) than predicted by inviscid theory (n approximately 0.6 instead of n = 0.667); however, the peak value of lift-drag ratio occurs at n = 0.667. Viscous effects were present on the bodies of polygonal cross section but were less pronounced than those on the power-law bodies. The trapezoidal bodies with maximum width at the bottom were found to have the highest maximum lift-drag ratio and the lowest mimimum drag.

  4. Impact Testing and Simulation of a Crashworthy Composite Fuselage Section with Energy-Absorbing Seats and Dummies

    NASA Technical Reports Server (NTRS)

    Fasanella, Edwin L.; Jackson, Karen E.

    2002-01-01

    A 25-ft/s vertical drop test of a composite fuselage section was conducted with two energy-absorbing seats occupied by anthropomorphic dummies to evaluate the crashworthy features of the fuselage section and to determine its interaction with the seats and dummies. The 5-ft. diameter fuselage section consists of a stiff structural floor and an energy-absorbing subfloor constructed of Rohacel foam blocks. The experimental data from this test were analyzed and correlated with predictions from a crash simulation developed using the nonlinear, explicit transient dynamic computer code, MSC.Dytran. The anthropomorphic dummies were simulated using the Articulated Total Body (ATB) code, which is integrated into MSC.Dytran.

  5. Impact Testing and Simulation of a Crashworthy Composite Fuselage Section with Energy-Absorbing Seats and Dummies

    NASA Technical Reports Server (NTRS)

    Fasanella, Edwin L.; Jackson, Karen E.

    2002-01-01

    A 25-ft/s vertical drop test of a composite fuselage section was conducted with two energy-absorbing seats occupied by anthropomorphic dummies to evaluate the crashworthy features of the fuselage section and to determine its interaction with the seats and dummies. The 5-ft diameter fuselage section consists of a stiff structural floor and an energy-absorbing subfloor constructed of Rohacel foam blocks. The experimental data from this test were analyzed and correlated with predictions from a crash simulation developed using the nonlinear, explicit transient dynamic computer code, MSC.Dytran. The anthropomorphic dummies were simulated using the Articulated Total Body (ATB) code, which is integrated into MSC.Dytran.

  6. High-resolution computed tomography evaluation of the bronchial lumen to vertebral body diameter and pulmonary artery to vertebral body diameter ratios in anesthetized ventilated normal cats.

    PubMed

    Lee-Fowler, Tekla M; Cole, Robert C; Dillon, A Ray; Tillson, D Michael; Garbarino, Rachel; Barney, Sharron

    2017-10-01

    Objectives Bronchial lumen to pulmonary artery diameter (BA) ratio has been utilized to investigate pulmonary pathology on high-resolution CT images. Diseases affecting both the bronchi and pulmonary arteries render the BA ratio less useful. The purpose of the study was to establish bronchial lumen diameter to vertebral body diameter (BV) and pulmonary artery diameter to vertebral body diameter (AV) ratios in normal cats. Methods Using high-resolution CT images, 16 sets of measurements (sixth thoracic vertebral body [mid-body], each lobar bronchi and companion pulmonary artery diameter) were acquired from young adult female cats and 41 sets from pubertal female cats. Results Young adult and pubertal cat BV ratios were not statistically different from each other in any lung lobe. Significant differences between individual lung lobe BV ratios were noted on combined age group analysis. Caudal lung lobe AV ratios were significantly different between young adult and pubertal cats. All other lung lobe AV ratios were not significantly different. Caudal lung lobe AV ratios were significantly different from all other lung lobes but not from each other in both the young adult and pubertal cats. Conclusions and relevance BV ratio reference intervals determined for individual lung lobes could be applied to both young adult and pubertal cats. Separate AV ratios for individual lung lobes would be required for young adult and pubertal cats. These ratios should allow more accurate evaluation of cats with concurrent bronchial and pulmonary arterial disease.

  7. Influence of pellet diameter and length on the quality of pellets and performance, nutrient utilisation and digestive tract development of broilers fed on wheat-based diets.

    PubMed

    Abdollahi, M R; Ravindran, V; Wester, T J; Ravindran, G; Thomas, D V

    2013-06-01

    1. The influence of pellet diameter and length on the quality of pellets and performance, nutrient utilisation and digestive tract development of broilers given wheat-based diets was examined from 10 to 42 d of age. The experimental design was a 2 × 2 factorial arrangement of treatments evaluating two pellet diameters (3 and 4.76 mm) and two pellet lengths (3 and 6 mm). From 0 to 9 d of age, all birds were offered a common starter diet pelleted with a 3-mm diameter die and 3-mm length. Broiler grower (d 10 to 21) and finisher (d 22 to 42) diets, based on wheat, were formulated and then subjected to the 4 different treatments. 2. In grower diets, increasing pellet diameter and pellet length reduced the gelatinised starch (GS) content of the diets. In finisher diets, GS content of 3-mm diameter pellets did not change with increasing pellet length but decreased in 4.76-mm diameter pellets. 3. In grower and finisher diets, increments in intact pellet weight, pellet durability index and pellet hardness with increasing pellet length were greater in 3-mm diameter pellets than those with 4.76-mm diameter. 4. Increasing pellet length from 3 to 6 mm increased apparent metabolisable energy values. Neither the interaction nor main effects were significant for the ileal digestibility of nitrogen and starch. 5. During the grower period (d 10 to 21), birds given pellets of 6-mm length had greater body-weight gain than those given 3-mm length pellets. Feeding 6-mm length pellets decreased feed per body-weight gain compared to 3-mm length pellets. During the finisher (d 22 to 42) and whole grow-out (d 10 to 42) periods, while different pellet lengths had no effect on feed per body-weight gain values at 3-mm pellet diameter, increasing the pellet length decreased feed per body-weight gain at 4.76-mm pellet diameter. 6. Increasing pellet diameter and pellet length reduced the relative length of duodenum. Birds given 3-mm diameter pellets had heavier proventriculus compared to those given 4.76-mm diameter pellets. 7. Overall, the data suggest that increasing the pellet length from 3 to 6 mm improved the body-weight gain and feed per body-weight gain during the grower period (d 10 to 21). While the positive effect on body-weight gain disappeared as the birds grew older, improvements in feed per body-weight gain were maintained over the finisher and whole grow-out periods only in 4.76-mm diameter pellets. Small diameter die holes and longer pellet lengths may be considered as potential manipulations to manufacture high-quality pellets under low conditioning temperatures.

  8. The morphometric study of l3-L4 and L4-L5 lumbar spine in Asian population using magnetic resonance imaging: feasibility analysis for transpsoas lumbar interbody fusion.

    PubMed

    Yusof, Mohd Imran; Nadarajan, Eswaran; Abdullah, Mohd Shafie

    2014-06-15

    Cross-sectional study on the measurement of relevant magnetic resonance imaging parameters in 100 patients presented for lumbar spine assessment. To determine anatomical position of lumbar plexus and major blood vessels in relation to vertebral body and anterior edge of psoas muscle at L3-L4 and L4-L5 and to define the safe working zone for transpsoas approach for lumbar fusion. Lateral transpsoas lumbar interbody fusion has been shown to be safe and provides alternative for lumbar fusion. However, proximity of neurovascular structures may not allow a safe passage for this procedure in the Asian population. Relevant parameters were measured from axial magnetic resonance images and analyzed, including the psoas muscle and vertebrae endplate diameters, lumbar plexus and psoas muscle distance, lumbar plexus and vertebra body distance, and vena cava to the anterior vertebrae body diameters. The mean anteroposterior diameters of the right and left psoas muscle ranged from 44.0 to 58.6 mm and 44.8 to 54.0 mm, respectively. The mean anteroposterior diameters of vertebra endplate of L3, L4, and L5 were 38.2 mm, 39.3 mm, and 41.4 mm, respectively. The mean distance of posterior border of vena cava from the vertebra body was 4.5 mm at L3-L4 and 14.1 mm at L4-L5. L3-L4 fusion is feasible at both sides in both sexes; however, at L4-L5 level, the procedure is feasible only on the left side. The safe working zone for transpsoas approach to lumbar spine is significantly narrower at L4-L5 in both sexes. Anterior edge of psoas muscle can be used as a reliable guide to locate lumbar plexus within psoas muscle. N/A.

  9. [Relationship between image quality and cross-sectional area of phantom in three-dimensional positron emission tomography scan].

    PubMed

    Osawa, Atsushi; Miwa, Kenta; Wagatsuma, Kei; Takiguchi, Tomohiro; Tamura, Shintaro; Akimoto, Kenta

    2012-01-01

    The image quality in (18)FDG PET/CT often degrades as the body size increases. The purpose of this study was to evaluate the relationship between image quality and the body size using original phantoms of variable cross-sectional areas in PET/CT. We produced five water phantoms with different cross-sectional areas. The long axis of phantom was 925 mm, and the cross-sectional area was from 324 to 1189 cm(2). These phantoms with the sphere (diameter 10 mm) were filled with (18)F-FDG solution. The radioactivity concentration of background in the phantom was 1.37, 2.73, 4.09 and 5.46 kBq/mL. The scanning duration was 30 min in list mode acquisition for each measurement. Background variability (N(10 mm)), noise equivalent count rates (NECR(phantom)), hot sphere contrast (Q(H,10 mm)) as physical evaluation and visual score of sphere detection were measured, respectively. The relationship between image quality and the various cross-sectional areas was also analyzed under the above-mentioned conditions. As cross-sectional area increased, NECR(phantom) progressively decreased. Furthermore, as cross-sectional area increased, N(10 mm) increased and Q(H,10 mm) decreased. Image quality became degraded as body weight increased because noise and contrast contributed to image quality. The visual score of sphere detection deteriorated in high background radioactivity concentration because a false positive detection in cross-sectional area of the phantom increased. However, additional increases in scanning periods could improve the visual score. We assessed tendencies in the relationship between image quality and body size in PET/CT. Our results showed that time adjustment was more effective than dose adjustment for stable image quality of heavier patients in terms of the large cross-sectional area.

  10. Three-dimensional workstation is useful for measuring the correct size of abdominal aortic aneurysm diameters.

    PubMed

    Ihara, Tsutomu; Komori, Kimihiro; Yamamoto, Kiyohito; Kobayashi, Masayoshi; Banno, Hiroshi; Kodama, Akio

    2013-02-01

    Abdominal aortic aneurysm diameter is usually measured by the maximum minor-axis diameter on axial computed tomography (CT). However, this "traditional" diameter may underestimate the real size, as the aorta is not always straight and the aneurysm shape is sometimes in the form of an ellipse along the cross section. Therefore, we measured maximum major-axis diameters using a three-dimensional (3D) workstation and compared them with the traditional maximum minor-axis diameters measured using thin-slice axial CT. CT data of 141 AAA patients (with fusiform aneurysms) were stored in a 3D workstation. These thin-slice CT images were reviewed on the 3D workstation to obtain curved multiplanar reconstruction images (CPR images). Using the CPR images, we measured the maximum major-axis and minor-axis diameters on CPR and the angle of the aneurysms to the body axis. The mean traditional maximum minor-axis diameter was 51.2 ± 8.2 mm, whereas the mean maximum major-axis diameter on CPR was 54.7 ± 10.1 mm. Sixty eight patients had a mean aneurysm size of <50 mm when measured by the traditional minor-axis diameter. Among these patients, five (7.4%) had a major-axis diameter >55 mm on CPR. The measurement of the traditional maximum minor-axis diameter of aneurysms is useful in the case of most patients. However, the traditional maximum minor-axis diameter may underestimate the real aneurysmal diameter, particularly in patients with an ellipse-shaped aneurysm. The maximum major-axis diameter as measured using CPR images is effective for representing the real aneurysmal size. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. Moon-Mercury: Large impact structures, isostasy and average crustal viscosity

    USGS Publications Warehouse

    Schaber, G.G.; Boyce, J.M.; Trask, N.J.

    1977-01-01

    Thirty-five craters and basins larger than 200 km in diameter are recognized on the imaged portion (45%) of Mercury. If the unimaged portion of the planet is similarly cratered, a total of 78 such impact features may be present. Sixty-two craters and basins 200 km in diameter are recognized on the moon, a body with only half the cross-sectional area of Mercury. If surface areas are considered, however, Mercury is cratered only 70% as densely as the moon. The density of impact craters with diameters greater than 400 km on Mercury is only 30% of that on the moon, and for craters with diameters between 400 and 700 km, the density on Mercury is only 21% of the lunar crater density. The size-frequency distribution curve for the large Mercurian craters follows the same cumulative -2 slope as the lunar curve but lies well below the 10% surface saturation level characteristic of the lunar curve. This is taken as evidence that the old heavily cratered terrain on Mercury is, at least presently, not in a state of cratering equilibrium. The reduced density of large craters and basins on Mercury relative to the moon could be either a function of the crater-production rates on these bodies or an effect of different crustal histories. Resurfacing of the planet after the basin-forming period is ruled out by the presence of 54 craters and basins 100 km in diameter and larger (on the imaged portion of Mercury) that have either well-defined or poorly-defined secondary-crater fields. Total isostatic compensation of impact craters ???800 km in diameter indicates that the average viscosity of the Mercurian crust over the past 4+ aeons was the same as that for the moon (???1026.5 P). This calculated viscosity and the distribution of large craters and basins suggest that either the very early crustal viscosity on Mercury was less than that of the moon and the present viscosity greater, or the differences in large crater populations on the two bodies is indeed the result of variations in rates of crater production. ?? 1977.

  12. The Effect of Nacelle-Propeller Diameter Ratio on Body Interference and on Propeller and Cooling Characteristics

    NASA Technical Reports Server (NTRS)

    Mchugh, James G; Derring, Eldridge H

    1939-01-01

    Report presents the results of an investigation conducted in the NACA 20-foot tunnel to determine the slipstream drag, the body interference, and the cooling characteristics of nacelle-propeller diameter. Four combinations of geometrically similar propellers and nacelles, mounted on standard wing supports, were tested with values of the ratio of nacelle diameter to propeller diameter of 0.25, 0.33, and 0.44.

  13. Validation of geometric measurements of the left atrium and pulmonary veins for analysis of reverse structural remodeling following ablation therapy

    NASA Astrophysics Data System (ADS)

    Rettmann, M. E.; Holmes, D. R., III; Gunawan, M. S.; Ge, X.; Karwoski, R. A.; Breen, J. F.; Packer, D. L.; Robb, R. A.

    2012-03-01

    Geometric analysis of the left atrium and pulmonary veins is important for studying reverse structural remodeling following cardiac ablation therapy. It has been shown that the left atrium decreases in volume and the pulmonary vein ostia decrease in diameter following ablation therapy. Most analysis techniques, however, require laborious manual tracing of image cross-sections. Pulmonary vein diameters are typically measured at the junction between the left atrium and pulmonary veins, called the pulmonary vein ostia, with manually drawn lines on volume renderings or on image cross-sections. In this work, we describe a technique for making semi-automatic measurements of the left atrium and pulmonary vein ostial diameters from high resolution CT scans and multi-phase datasets. The left atrium and pulmonary veins are segmented from a CT volume using a 3D volume approach and cut planes are interactively positioned to separate the pulmonary veins from the body of the left atrium. The cut plane is also used to compute the pulmonary vein ostial diameter. Validation experiments are presented which demonstrate the ability to repeatedly measure left atrial volume and pulmonary vein diameters from high resolution CT scans, as well as the feasibility of this approach for analyzing dynamic, multi-phase datasets. In the high resolution CT scans the left atrial volume measurements show high repeatability with approximately 4% intra-rater repeatability and 8% inter-rater repeatability. Intra- and inter-rater repeatability for pulmonary vein diameter measurements range from approximately 2 to 4 mm. For the multi-phase CT datasets, differences in left atrial volumes between a standard slice-by-slice approach and the proposed 3D volume approach are small, with percent differences on the order of 3% to 6%.

  14. Stability Characteristics of Two Missiles of Fineness Ratios 12 and 18 with Six Rectangular Fins of Very Low Aspect Ratio Over a Mach Number Range of 1.4 to 3.2

    NASA Technical Reports Server (NTRS)

    Henning, Allen B.

    1959-01-01

    Two rocket-propelled missiles have been test flown by the Langley Pilotless Aircraft Research Division in order to study the stability characteristics of a body with six rectangular fins of very low aspect ratio. The fins, which had exposed aspect ratios of approximately o.o4 and 0.02 per fin, were mounted on bodies of fineness ratios of 12 and 18, respectively. Each body had a nose with a fineness ratio of 3.5 and a cylindrical afterbody. The body and the fin chord of the model having a fineness ratio of 12 were extended the length of 6 body diameters to produce the model with a fineness ratio of 18. The missiles were disturbed in flight by pulse rockets in order to obtain the stability data. The tests were performed over a Mach number range of 1.4 to 3.2 and a Reynolds number range of 2 x 10(exp 6) to 21 x l0(exp 6). The results of these tests indicate that these configurations with the long rectangular fins of very low aspect ratio showed little induced roll" with the missile of highest fineness ratio and longest fin chord exhibiting the least amount. Extending the body and fin chord of the shorter missile six body diameters and thereby increasing the fin area approximately 115 percent increased the lift-curve slope based on body cross-sectional area approximately 40 to 55 percent, increased the dynamic stability by a substantial amount, and increased the drag from 14 to 33 percent throughout the comparable Mach number range. The center-of-pressure location of both missiles remained constant over the Mach number range.

  15. Body frame size in school children is related to the amount of adipose tissue in different depots but not to adipose distribution.

    PubMed

    Guzmán-de la Garza, Francisco J; González Ayala, Alejandra E; Gómez Nava, Marisol; Martínez Monsiváis, Leislie I; Salinas Martínez, Ana M; Ramírez López, Erik; Mathiew Quirós, Alvaro; Garcia Quintanilla, Francisco

    2017-09-10

    The main aim of this study was to test the hypothesis that body frame size is related to the amount of fat in different adipose tissue depots and to fat distribution in schoolchildren. Children aged between 5 and 10 years were included in this cross-sectional study (n = 565). Body frame size, adiposity markers (anthropometric, skinfolds thickness, and ultrasound measures), and fat distribution indices were analyzed. Correlation coefficients adjusted by reliability were estimated and analyzed by sex; the significance of the difference between two correlation coefficients was assessed using the Fisher z-transformation. The sample included primarily urban children; 58.6% were normal weight, 16.1% overweight, 19.6% obese, and the rest were underweight. Markers of subcutaneous adiposity, fat mass and fat-free mass, and preperitoneal adiposity showed higher and significant correlations with the sum of the biacromial + bitrochanteric diameter than with the elbow diameter, regardless of sex. The fat distribution conicity index presented significant but weak correlations; and visceral adipose tissue, hepatic steatosis, and the waist-for-hip ratio were not significantly correlated with body frame size measures. Body frame size in school children was related to the amount of adipose tissue in different depots, but not adipose distribution. More studies are needed to confirm this relationship and its importance to predict changes in visceral fat deposition during growth. © 2017 Wiley Periodicals, Inc.

  16. Isotachophoresis system having larger-diameter channels flowing into channels with reduced diameter and with selectable counter-flow

    DOEpatents

    Mariella, Jr., Raymond P.

    2018-03-06

    An isotachophoresis system for separating a sample containing particles into discrete packets including a flow channel, the flow channel having a large diameter section and a small diameter section; a negative electrode operably connected to the flow channel; a positive electrode operably connected to the flow channel; a leading carrier fluid in the flow channel; a trailing carrier fluid in the flow channel; and a control for separating the particles in the sample into discrete packets using the leading carrier fluid, the trailing carrier fluid, the large diameter section, and the small diameter section.

  17. Body mass and stature estimation based on the first metatarsal in humans.

    PubMed

    De Groote, Isabelle; Humphrey, Louise T

    2011-04-01

    Archaeological assemblages often lack the complete long bones needed to estimate stature and body mass. The most accurate estimates of body mass and stature are produced using femoral head diameter and femur length. Foot bones including the first metatarsal preserve relatively well in a range of archaeological contexts. In this article we present regression equations using the first metatarsal to estimate femoral head diameter, femoral length, and body mass in a diverse human sample. The skeletal sample comprised 87 individuals (Andamanese, Australasians, Africans, Native Americans, and British). Results show that all first metatarsal measurements correlate moderately to highly (r = 0.62-0.91) with femoral head diameter and length. The proximal articular dorsoplantar diameter is the best single measurement to predict both femoral dimensions. Percent standard errors of the estimate are below 5%. Equations using two metatarsal measurements show a small increase in accuracy. Direct estimations of body mass (calculated from measured femoral head diameter using previously published equations) have an error of just over 7%. No direct stature estimation equations were derived due to the varied linear body proportions represented in the sample. The equations were tested on a sample of 35 individuals from Christ Church Spitalfields. Percentage differences in estimated and measured femoral head diameter and length were less than 1%. This study demonstrates that it is feasible to use the first metatarsal in the estimation of body mass and stature. The equations presented here are particularly useful for assemblages where the long bones are either missing or fragmented, and enable estimation of these fundamental population parameters in poorly preserved assemblages. Copyright © 2011 Wiley-Liss, Inc.

  18. [Measurements of location of body fat distribution: an assessment of colinearity with body mass, adiposity and stature in female adolescents].

    PubMed

    Pereira, Patrícia Feliciano; Serrano, Hiara Miguel Stanciola; Carvalho, Gisele Queiroz; Ribeiro, Sônia Machado Rocha; Peluzio, Maria do Carmo Gouveia; Franceschini, Sylvia do Carmo Castro; Priore, Silvia Eloiza

    2015-01-01

    To verify the correlation between body fat location measurements with the body mass index (BMI), percentage of body fat (%BF) and stature, according to the nutritional status in female adolescents. A controlled cross sectional study was carried out with 113 adolescents (G1: 38 eutrophic, but with high body fat level, G2: 40 eutrophic and G3: 35 overweight) from public schools in Viçosa-MG, Brazil. The following measures have been assessed: weight, stature, waist circumference (WC), umbilical circumference (UC), hip circumference (HC), thigh circumference, waist-to-hip ratio (WHR), waist-to-stature ratio (WSR), waist-to-thigh ratio (WTR), conicity index (CI), sagittal abdominal diameter (SAD), coronal diameter (CD), central skinfolds (CS) and peripheral (PS). The %BF was assessed by tetrapolar electric bioimpedance. The increase of central fat, represented by WC, UC, WSR, SAD, CD and CS, and the increase of peripheral fat indicated by HC and thigh were proportional to the increase of BMI and %BF. WC and especially the UC showed the strongest correlations with adiposity. Weak correlation between WHR, WTR, CI and CS/PS with adiposity were observed. The stature showed correlation with almost all the fat location measures, being regular or weak with waist. The results indicate colinearity between body mass and total adiposity with central and peripheral adipose tissue. We recommend the use of UC for assessing nutritional status of adolescents, because it showed the highest ability to predict adiposity in each group, and also presented regular or weak correlation with stature. Copyright © 2014 Associação de Pediatria de São Paulo. Publicado por Elsevier Editora Ltda. All rights reserved.

  19. Aerodynamic Characteristics at a Mach Number of 3.10 of Several Fourth-Stage Shapes of the Scout Research Vehicle

    NASA Technical Reports Server (NTRS)

    Jaquet, Byron M.

    1961-01-01

    A wind-tunnel investigation was made at a Mach number of 3.10 (Reynolds number per foot of 16.3 x 10(exp 6) to 16.9 x 10(exp 6)) to determine the aerodynamic characteristics of various modifications of the payload section of the fourth stage of the Scout research vehicle. It was found that, for the combination of stages 3 and 4, increasing the size of the nose of the basic Scout to provide a cylindrical section of the same diameter as the third stage increased the normal-force slope by about 30 percent, the axial force by about 39 percent, and moved the center of pressure forward by about one fourth-stage base diameter. By reducing the diameter of the cylinder, at about one nose length behind the base of the enlarged nose frustum, to that of the basic Scout and thereafter retaining the shape of the basic Scout, the center of pressure was moved rearward by about one-half fourth-stage base diameter at the expense of an additional 19-percent increase in axial force. A spike-hemisphere configuration had the largest forces and moments and the most forward center-of-pressure location of the configurations considered. Except for the axial force and pitching-moment slope, the experimental trends or magnitudes could not be estimated with the desired accuracy by Newtonian or-slender body theory.

  20. Reactions of the rat musculoskeletal system to compressive spinal cord injury (SCI) and whole body vibration (WBV) therapy

    PubMed Central

    Schwarz, A.; Pick, C.; Harrach, R.; Stein, G.; Bendella, H.; Ozsoy, O.; Ozsoy, U.; Schoenau, E.; Jaminet, P.; Sarikcioglu, L.; Dunlop, S.; Angelov, D.N.

    2015-01-01

    Traumatic spinal cord injury (SCI) causes a loss of locomotor function with associated compromise of the musculo-skeletal system. Whole body vibration (WBV) is a potential therapy following SCI, but little is known about its effects on the musculo-skeletal system. Here, we examined locomotor recovery and the musculo-skeletal system after thoracic (T7-9) compression SCI in adult rats. Daily WBV was started at 1, 7, 14 and 28 days after injury (WBV1-WBV28 respectively) and continued over a 12-week post-injury period. Intact rats, rats with SCI but no WBV (sham-treated) and a group that received passive flexion and extension (PFE) of their hind limbs served as controls. Compared to sham-treated rats, neither WBV nor PFE improved motor function. Only WBV14 and PFE improved body support. In line with earlier studies we failed to detect signs of soleus muscle atrophy (weight, cross sectional diameter, total amount of fibers, mean fiber diameter) or bone loss in the femur (length, weight, bone mineral density). One possible explanation is that, despite of injury extent, the preservation of some axons in the white matter, in combination with quadripedal locomotion, may provide sufficient trophic and neuronal support for the musculoskeletal system. PMID:26032204

  1. Reactions of the rat musculoskeletal system to compressive spinal cord injury (SCI) and whole body vibration (WBV) therapy.

    PubMed

    Schwarz, A; Pick, C; Harrach, R; Stein, G; Bendella, H; Ozsoy, O; Ozsoy, U; Schoenau, E; Jaminet, P; Sarikcioglu, L; Dunlop, S; Angelov, D N

    2015-06-01

    Traumatic spinal cord injury (SCI) causes a loss of locomotor function with associated compromise of the musculo-skeletal system. Whole body vibration (WBV) is a potential therapy following SCI, but little is known about its effects on the musculo-skeletal system. Here, we examined locomotor recovery and the musculo-skeletal system after thoracic (T7-9) compression SCI in adult rats. Daily WBV was started at 1, 7, 14 and 28 days after injury (WBV1-WBV28 respectively) and continued over a 12-week post-injury period. Intact rats, rats with SCI but no WBV (sham-treated) and a group that received passive flexion and extension (PFE) of their hind limbs served as controls. Compared to sham-treated rats, neither WBV nor PFE improved motor function. Only WBV14 and PFE improved body support. In line with earlier studies we failed to detect signs of soleus muscle atrophy (weight, cross sectional diameter, total amount of fibers, mean fiber diameter) or bone loss in the femur (length, weight, bone mineral density). One possible explanation is that, despite of injury extent, the preservation of some axons in the white matter, in combination with quadripedal locomotion, may provide sufficient trophic and neuronal support for the musculoskeletal system.

  2. Morphometric Correlates of the Ovary and Ovulatory Corpora in the Bowhead Whale, Balaena mysticetus.

    PubMed

    Tarpley, Raymond J; Hillmann, Daniel J; George, John C; Zeh, Judith E; Suydam, Robert S

    2016-06-01

    Gross morphology and morphometry of the bowhead whale ovary, including ovulatory corpora, were investigated in 50 whales from the Chukchi and Beaufort seas off the coast of Alaska. Using the presence of ovarian corpora to define sexual maturity, 23 sexually immature whales (7.6-14.2 m total body length) and 27 sexually mature whales (14.2-17.7 m total body length) were identified. Ovary pair weights ranged from 0.38 to 2.45 kg and 2.92 to 12.02 kg for sexually immature and sexually mature whales, respectively. In sexually mature whales, corpora lutea (CLs) and/or large corpora albicantia (CAs) projected beyond ovary surfaces. CAs became increasingly less interruptive of the surface contour as they regressed, while remaining identifiable within transverse sections of the ovarian cortex. CLs formed large globular bodies, often with a central lumen, featuring golden parenchymas enfolded within radiating fibrous cords. CAs, sometimes vesicular, featured a dense fibrous core with outward fibrous projections through the former luteal tissue. CLs (never more than one per ovary pair) ranged from 6.7 to 15.0 cm in diameter in 13 whales. Fetuses were confirmed in nine of the 13 whales, with the associated CLs ranging from 8.3 to 15.0 cm in diameter. CLs from four whales where a fetus was not detected ranged from 6.7 to 10.6 cm in diameter. CA totals ranged from 0 to 22 for any single ovary, and from 1 to 41 for an ovary pair. CAs measured from 0.3 to 6.3 cm in diameter, and smaller corpora were more numerous, suggesting an accumulating record of ovulation. Neither the left nor the right ovary dominated in the production of corpora. Anat Rec, 299:769-797, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Using pre-operative MRI to predict intraoperative hamstring graft size for anterior cruciate ligament reconstruction.

    PubMed

    Leiter, Jeff; Elkurbo, Mohamed; McRae, Sheila; Chiu, James; Froese, Warren; MacDonald, Peter

    2017-01-01

    Large variation in tendon size between individuals makes hamstring graft diameter for anterior cruciate ligament (ACL) reconstruction unpredictable. Inadequate graft diameter may necessitate an alternative source of tissue requiring pre-operative planning. The purpose of this study was to determine whether magnetic resonance image (MRI) measurements and clinical anthropometric data are predictive of hamstring tendon graft diameter. Data from 109 patients having ACL reconstruction with semitendinosus-gracilis (STGT) autograft were retrospectively evaluated. Cross-sectional area (CSA) of the gracilis tendon (GT) and semitendinosus tendon (ST) were determined from pre-operative MRI scans. Variables included pre-operative height, weight, body mass index (BMI), age and gender; and intra-operative graft diameter. Correlations between anthropometric variables, hamstring tendons CSA and intra-operative graft diameter were calculated. Multiple stepwise regression was performed to assess the predictive value of these variables to graft diameter. Sensitivity and specificity were calculated to evaluate the utility of MRI CSA measurements in accurately identifying inadequate graft diameter (<8 mm). All anthropometric variables were positively correlated with intraoperative graft diameter (p < 0.01). Semitendinosus-gracilis tendon CSA (p < 0.001) and STGT CSA and weight (p < 0.001) were significantly predictive models of graft diameter. Sensitivity and specificity were 79 and 74 %, respectively. The strongest indicators of a four-stranded STGT graft for primary ACL reconstruction were STGT CSA on MRI plus weight. Measurement of graft diameter can be performed pre-operatively via MRI to identify tendons that may be of inadequate size for ACL reconstruction. This can assist with surgical planning to determine the most appropriate graft choice. III.

  4. Arterial stiffness, body fat compartments, central hemodynamics, renal function and left atrial size.

    PubMed

    Katulska, Katarzyna; Milewska, Agata; Wykretowicz, Mateusz; Krauze, Tomasz; Przymuszala, Dagmara; Piskorski, Jaroslaw; Stajgis, Marek; Guzik, Przemyslaw; Wysocki, Henryk; Wykrętowicz, Andrzej

    2013-10-01

    Left atrial (LA) size is an important predictor of stroke, death, and atrial fibrillation. It was demonstrated recently that body fat, arterial stiffness and renal functions are associated with LA diameter. However, data are lacking for comprehensive assessments of all these risk factors in a single population. Therefore, the aim of the present study was to investigate the association between LA size and different fat descriptors, central hemodynamics, arterial stiffness, and renal function in healthy subjects. To this end, body fat percentage, abdominal, subcutaneous fat, and general descriptors of body fat were estimated in 162 healthy subjects (mean age 51 years). Echocardiography was performed to assess LA diameter. Arterial stiffness and peripheral and central hemodynamics were estimated by digital volume pulse analysis and pulse wave analysis. Glomerular filtration rate was estimated by MDRD formula. There were significant (p < 0.05) bivariate correlations between LA diameter and all descriptors of body fat (except subcutaneous fat). Arterial stiffness and estimated glomerular filtration rate (eGFR) were also significantly correlated with LA size. Multiple regression analysis including all significant confounders, such as sex, mean arterial pressure, arterial stiffness, eGFR and body fat descriptors, explained 35% of variance in LA diameter. In conclusion, the present study reveals significant, independent relationships between body fat, arterial stiffness, and LA size.

  5. Experimental aerodynamic characteristics for slender bodies with thin wings and tail at angles of attack from 0 deg to 58 deg and Mach numbers from 0.6 to 2.0

    NASA Technical Reports Server (NTRS)

    Jorgensen, L. H.; Nelson, E. R.

    1976-01-01

    An experimental investigation was conducted by wind tunnel to measure the static aerodynamic characteristics for bodies of circular and elliptic cross section with various thin flat plate wings and a thin tail consisting of horizontal and vertical parts. The wings had aspect ratios of 4 and taper ratios of about 0, 0.25, and 0.5. Two additional wings, which had taper ratios near 0.25 and aspect ratios of about 3 and 5, were also tested in combination with the bodies and tail. All wings had about the same planform area. The exposed area of the horizontal portion of the tail was about 33 to 36 percent of the exposed area of the wings. The exposed area of the vertical tail fin was about 22 to 24 percent of the exposed area of the wings. The elliptic body, with an a/b = 2 cross section, had the same length and axial distribution of cross sectional area as the circular body. The circular body had a cylindrical aftersection of fineness ratio 7, and it was tested with the wings and tail in combination with tangent ogive noses that had fineness ratios of 2.5, 3.0, 3.5, and 5.0. In addition, an ogive nose with a rounded tip and an ogive nose with two different nose strake arrangements were used. Nineteen configuration combinations were tested at Mach numbers of 0.6, 0.9, 1.5, and 2.0 at angles of attack from 0 to 58 deg. The Reynolds numbers, based on body base diameter, were about 4.3 X 100,000.

  6. THE FINE STRUCTURE OF Streptomyces coelicolor

    PubMed Central

    Hopwood, David A.; Glauert, Audrey M.

    1960-01-01

    Colonies and spore suspensions of Streptomyces coelicolor were fixed for electron microscopy by the method of Kellenberger, Ryter, and Séchaud (1958). In thin sections the nuclear regions have a lower average density than the cytoplasm and the outlines of these regions correspond well with the profiles of the chromatinic bodies observed with the light microscope. The nuclear regions contain fibrils, about 5 mµ in diameter. In contrast, after fixation by the method of Palade (1952) the nuclear material is coagulated into irregular dense masses and tubular structures about 20 mµ in diameter, lying in a nuclear "vacuole." The significance of these observations is discussed in relation to the observations of other workers on the fine structure of the nuclear material of other bacteria and the chromosomes of higher cells. PMID:13715794

  7. Effect of Body Nose Shape on the Propulsive Efficiency of a Propeller

    NASA Technical Reports Server (NTRS)

    Stickle, George W; Crigler, John L; Naiman, Irven

    1941-01-01

    Report presents the results of an investigation of the propulsive efficiency of three adjustable propellers of 10-foot diameter operated in front of four body nose shapes, varying from streamline nose that continued through the propeller plane in the form of a large spinner to a conventional open-nose radial-engine cowling. One propeller had airfoil sections close to the hub, the second had conventional round blade shanks, and the third differed from the second only in pitch distribution. The blade-angle settings ranged from 20 degrees to 55 degrees at the 0.75 radius. The effect of the body nose shape on propulsive efficiency may be divided into two parts: (1) the change in the body drag due to the propeller slipstream and (2) the change in propeller load distribution due to the change in velocity caused by the body. For the nose shape tested in the report, the first effect is shown to be very small; therefore, the chief emphasis of the report is confined to the second effect.

  8. Normal limits in relation to age, body size and gender of two-dimensional echocardiographic aortic root dimensions in persons ≥15 years of age.

    PubMed

    Devereux, Richard B; de Simone, Giovanni; Arnett, Donna K; Best, Lyle G; Boerwinkle, Eric; Howard, Barbara V; Kitzman, Dalane; Lee, Elisa T; Mosley, Thomas H; Weder, Alan; Roman, Mary J

    2012-10-15

    Nomograms to predict normal aortic root diameter for body surface area (BSA) in broad ranges of age have been widely used but are limited by lack of consideration of gender effects, jumps in upper limits of aortic diameter among age strata, and data from older teenagers. Sinus of Valsalva diameter was measured by American Society of Echocardiography convention in normal-weight, nonhypertensive, nondiabetic subjects ≥15 years old without aortic valve disease from clinical or population-based samples. Analyses of covariance and linear regression with assessment of residuals identified determinants and developed predictive models for normal aortic root diameter. In 1,207 apparently normal subjects ≥15 years old (54% women), aortic root diameter was 2.1 to 4.3 cm. Aortic root diameter was strongly related to BSA and height (r = 0.48 for the 2 comparisons), age (r = 0.36), and male gender (+2.7 mm adjusted for BSA and age, p <0.001 for all comparisons). Multivariable equations using age, gender, and BSA or height predicted aortic diameter strongly (R = 0.674 for the 2 comparisons, p <0.001) with minimal relation of residuals to age or body size: for BSA 2.423 + (age [years] × 0.009) + (BSA [square meters] × 0.461) - (gender [1 = man, 2 = woman] × 0.267), SEE 0.261 cm; for height 1.519 + (age [years] × 0.010) + (height [centimeters] × 0.010) - (gender [1 = man, 2 = woman] × 0.247), SEE 0.215 cm. In conclusion, aortic root diameter is larger in men and increases with body size and age. Regression models incorporating body size, age, and gender are applicable to adolescents and adults without limitations of previous nomograms. Copyright © 2012 Elsevier Inc. All rights reserved.

  9. The septal body revisited.

    PubMed

    Elwany, S; Salam, S A; Soliman, A; Medanni, A; Talaat, E

    2009-03-01

    The term septal body refers to a thickened area of the nasal septum which is located superior to the inferior turbinate and anterior to the middle turbinate. Despite its important role in changing nasal airflow resistance, it has received little attention. Clinically, a well developed septal body may be misdiagnosed as high septal deviation. The aim of the present study was to reassess the histological characteristics of the septal body mucosa and the morphometric differences between it and the adjacent septal mucosa. This information was then used to determine the exact location and surface area of the septal body. The study was performed on 30 cadaveric specimens (60 sides). Serial numbered sections of the whole septal mucosa were stained with haematoxylin and eosin as well as periodic acid Schiff - Alcian blue. Morphometric analysis was performed to determine the histological differences between the septal body mucosa, the anterior septal mucosa and the inferior septal mucosa. The precise boundaries of the septal body area were then defined in a manner similar to the Mohs micrographic surgical technique. The histological characteristics of the septal body mucosa included thick (more than 60 microm), pseudostratified, ciliated respiratory epithelium with goblet cells, abundant seromucinous glands and many blood sinusoids. Morphometric analysis showed that the septal body mucosa had thicker epithelium and more glandular acini and blood sinusoids than the rest of the septal mucosa. Mapping of the septal body area showed that its anterior end was 2.2 +/- 0.3 cm (mean +/- standard deviation) behind the caudal edge of the septal cartilage, and its inferior border was 1.1 +/- 0.2 cm above the floor of the nose. The mean horizontal diameter of the septal body was 2.0 +/- 0.15 cm, and the mean vertical diameter was 1.5 +/- 0.11 cm. The present study determined the morphometric characteristics of the septal body as well as its location and surface area. The intimate relationship of the septal body to the internal nasal valve and the histological characteristics of its mucosa should stimulate research into its potential role in modifying nasal airflow pattern and resistance, and its role in changing the humidity and temperature of the inspiratory air stream.

  10. [Body build and radiation exposure in static roentgen studies (I): A contribution for determining a national reference dose value. Promoted by the Federal Office for Radiation Protection (St.Sch 4163)].

    PubMed

    Golder, W; Weiner, G

    2001-06-01

    To contribute data on radiation exposure in static x-ray procedures and to compare them with anthropometric parameters. 121 chest x-rays and 100 lumbar spine examinations were carried out and the dose-area product (DAP) measured for each of the projections. Additionally, body height, body weight and the sagittal and transversal diameters of the examined regions were recorded. Dose measurements were statistically evaluated and the following data determined: Frequency distribution, median, 25%- and 75%-percentiles as well as correlations with sex, body weight and diameters. Median DAP was 13 (men: 16; women: 11) resp. 50 (62; 37) cGycm2 with pa resp lateral chest x-ray. Values were closely correlated with body weight (r = 0.704/0.659) and diameter of the chest (r = 0.657/0.579). Median DAP was 175 (239; 126) resp 531 (670; 361) cGycm2 with ap resp lateral lumbar spine examinations. Values were closely correlated with body weight (r = 0.678/0.666) and diameter of the abdomen (r = 0.664/0.658). DAP of chest x-rays and lumbar spine examinations is strongly influenced by the constitution of the patients. Men are nearly twice as largely exposed to radiation as women.

  11. The search for valved conduit tissue grafts for adults (>22 mm): an ultrasonographic study of jugular vein diameters of horses and cattle

    PubMed Central

    Schwarzwald, Colin C; Jenni, Rolf

    2009-01-01

    Background Natural heterologous valved conduits with a diameter greater than 22 mm that can be used for right ventricular outflow tract reconstruction in adults are not commercially available. The purpose of this study was to measure by ultrasonography the maximum diameter of the distended jugular veins of horses and cattle, respectively, to identify a population of animals that would be suitable for post-mortem collection of jugular veins at sizes greater than 22 mm. Methods The study population included 60 Warmblood horses, 25 Freiberger horses, 20 Brown Swiss cows, and 20 Holstein cows (including 10 Holstein and 10 Red Holstein). The maximum cross-sectional diameter of the distended jugular veins was measured at a location half-way between the mandibular angle and the thoracic inlet. The thoracic circumference (heart girth length) was used as a surrogate of body size. The jugular vein diameters of the different populations were compared by analysis of variance and the association between heart girth length and jugular vein diameter was determined in each of the four study populations by linear regression analysis. Results There was considerable individual variation of jugular vein diameters within each of the four study populations. There was no statistically significant relationship between thoracic circumference and jugular vein diameter in any of the populations. The jugular vein diameters of Brown Swiss cows were significantly larger than those of any of the other populations. Warmblood horses had significantly larger jugular vein diameters compared to Freiberger horses. Conclusion The results of this study suggest that the production of bovine or equine xenografts with diameters of greater than 22 mm would be feasible. Differences between species and breeds need to be considered. However, prediction of the jugular vein diameter based on breed and heart girth length in an individual animal is inaccurate. PMID:19678940

  12. Technical note: estimating absorbed doses to the thyroid in CT.

    PubMed

    Huda, Walter; Magill, Dennise; Spampinato, Maria V

    2011-06-01

    To describe a method for estimating absorbed doses to the thyroid in patients undergoing neck CT examinations. Thyroid doses in anthropomorphic phantoms were obtained for all 23 scanner dosimetry data sets in the ImPACT CT patient dosimetry calculator. Values of relative thyroid dose [R(thy)(L)], defined as the thyroid dose for a given scan length (L) divided by the corresponding thyroid dose for a whole body scan, were determined for neck CT scans. Ratios of the maximum thyroid dose to the corresponding CTDI(vol) and [D'(thy)], were obtained for two phantom diameters. The mass-equivalent water cylinder of any patient can be derived from the neck cross-sectional area and the corresponding average Hounsfield Unit, and compared to the 16.5-cm diameter water cylinder that models the ImPACT anthropomorphic phantom neck. Published values of relative doses in water cylinders of varying diameter were used to adjust thyroid doses in the anthropomorphic phantom to those of any sized patient. Relative thyroid doses R(thy)(L) increase to unity with increasing scan length and with very small difference between scanners. A 10-cm scan centered on the thyroid would result in a dose that is, nearly 90% of the thyroid dose from a whole body scan when performed using the constant radiographic techniques. At 120 kV, the average value of D'(thy) for the 16-cm diameter was 1.17 +/- 0.05 and was independent of CT vendor and year of CT scanner, and choice of x-ray tube voltage. The corresponding average value of D'(thy) in the 32-cm diameter phantom was 2.28 +/- 0.22 and showed marked variations depending on vendor, year of introduction into clinical practice as well as x-ray tube voltage. At 120 kV, a neck equivalent to a 10-cm diameter cylinder of water would have thyroid doses 36% higher than those in the ImPACT phantom, whereas a neck equivalent to a 25-cm cylinder diameter would have thyroid doses 35% lower. Patient thyroid doses can be estimated by taking into account the amount of radiation used to perform the CT examination (CTDI(vol)) and accounting for scan length and patient anatomy (i.e., neck diameter) at the thyroid location.

  13. Vertical drop test of a transport fuselage section located aft of the wing

    NASA Technical Reports Server (NTRS)

    Fasanella, E. L.; Alfaro-Bou, E.

    1986-01-01

    A 12-foot long Boeing 707 aft fuselage section with a tapering cross section was drop tested at the NASA Langley Research Center to measure structural, seat, and occupant response to vertical crash laods and to provide data for nonlinear finite element modeling. This was the final test in a series of three different transport fuselage sections tested under identical conditions. The test parameters at impact were: 20 ft/s velocity, and zero pitch, roll, and yaw. In addition, the test was an operational shock test of the data acquisition system used for the Controlled Impact Demonstration (CID) of a remotely piloted Boeing 720 that was crash tested at NASA Ames Dryden Flight Research Facility on December 1, 1984. Post-test measurements of the crush showed that the front of the section (with larger diameter) crushed vertically approximately 14 inches while the rear crushed 18 inches. Analysis of the data traces indicate the maximum peak normal (vertical) accelerations at the bottom of the frames were approximately 109 G at body station 1040 and 64 G at body station 1120. The peak floor acceleration varied from 14 G near the wall to 25 G near the center where high frequency oscillations of the floor were evident. The peak anthropomorphic dummy pelvis normal (vertical) acceleration was 19 G's.

  14. Characteristics of the Langley 8-foot Transonic Tunnel with Slotted Test Section

    NASA Technical Reports Server (NTRS)

    Wright, Ray H; Ritchie, Virgil S; Pearson, Albin O

    1958-01-01

    A large wind tunnel, approximately 8 feet in diameter, has been converted to transonic operation by means of slots in the boundary extending in the direction of flow. The usefulness of such a slotted wind tunnel, already known with respect to the reduction of the subsonic blockage interference and the production of continuously variable supersonic flows, has been augmented by devising a slot shape with which a supersonic test region with excellent flow quality could be produced. Experimental locations of detached shock waves ahead of axially symmetric bodies at low supersonic speeds in the slotted test section agreed satisfactorily with predictions obtained by use of existing approximate methods.

  15. Simulations of Collisional Disruption at the Catastrophic Impact Energy Threshold: Effect of the Target's Internal Structure and Diameter

    NASA Astrophysics Data System (ADS)

    Michel, P.; Benz, W.; Richardson, D. C.

    2005-08-01

    Recent simulations of asteroid break-ups, including both the fragmentation of the parent body and the gravitational interactions of the fragments, have allowed to reproduced successfully the main properties of asteroid families formed in different regimes of impact energy. Here, using the same kind of simulations, we concentrate on a single regime of impact energy, the so-called catastrophic threshold usually designated by Qcrit, which results in the escape of half of the target's mass. Considering a wide range of diameter values and two kinds of internal structures of the parent body, monolithic and pre-shattered, we analyse their potential influences on the value of Qcrit and on the collisional outcome limited here to the fragment size and ejection speed distributions, which are the main outcome properties used by collisional models to study the evolutions of the different populations of small bodies. For all the considered diameters and the two internal structures of the parent body, we confirm that the process of gravitational reaccumulation is at the origin of the largest remnant's mass. We then find that, for a given diameter of the parent body, the impact energy corresponding to the catastrophic disruption threshold is highly dependent on the internal structure of the parent body. In particular, a pre-shattered parent body containing only damaged zones but no macroscopic voids is easier to disrupt than a monolithic parent body. Other kinds of internal properties that can also characterize small bodies in real populations will be investigated in a future work.

  16. Quantitative three-dimensional dynamic imaging of structure and function of the cardiopulmonary and circulatory systems in all regions of the body

    NASA Technical Reports Server (NTRS)

    Sturm, R. E.; Ritman, E. L.; Wood, E. H.

    1975-01-01

    The background for, and design of a third generation, general purpose, all electronic spatial scanning system, the DSR is described. Its specified performance capabilities provide dynamic and stop action three dimensional spatial reconstructions of any portion of the body based on a minimum exposure time of 0.01 second for each 28 multiplanar 180 deg scanning set, a maximum scan repetition rate of sixty 28 multiplane scan sets per second, each scan set consisting of a maximum of 240 parallel cross sections of a minimum thickness of 0.9 mm, and encompassing a maximum cylindrical volume about 23 cm in length and up to 38 cm in diameter.

  17. "Reticular" and "Areticular" Nissl Bodies in Sympathetic Neurons of a Lizard

    PubMed Central

    Smith, Stuart W.

    1959-01-01

    Sympathetic ganglia of the horned lizard, Phrynosoma cornutum, were fixed in OsO4 and imbedded in methacrylate. Thin sections were cut for electron microscopy. Some adjacent thick sections were cut for light microscopy and were stained in acidified, dilute thionine both before and after digestion by RNase. In the light microscope two types of Nissl bodies are found, both removable by RNase: (1) a deep, diffuse, indistinctly bounded, metachromatic variety, and (2) a superficial, dense, sharply delimited, orthochromatic sort. Electron microscopically, the former ("reticular" Nissl bodies) corresponds to the granulated endoplasmic reticular structure of Nissl material previously described by others, whereas the latter ("areticular" Nissl bodies) comprises compact masses of particles of varying internal density and devoid of elements of endoplasmic reticulum. The constituent particles of the areticular Nissl material are 4 to 8 x the diameter of single ribonucleoprotein granules of the reticular Nissl substance and seem, near zones of junction with the reticular type, to arise by clustering of such granules with subsequent partial dispersion of the substance of the granules into an added, less dense material. It is suggested that the observed orthochromasia of the areticular Nissl substance is due to accumulation of a large amount of protein bound to RNA and, further, that these Nissl bodies may represent storage depots of RNA and protein. PMID:13673051

  18. Cardiovascular risk factors and retinal microvascular signs in an adult Japanese population: the Funagata Study.

    PubMed

    Kawasaki, Ryo; Wang, Jie Jin; Rochtchina, Elena; Taylor, Bronwen; Wong, Tien Yin; Tominaga, Makoto; Kato, Takeo; Daimon, Makoto; Oizumi, Toshihide; Kawata, Sumio; Kayama, Takamasa; Yamashita, Hidetoshi; Mitchell, Paul

    2006-08-01

    To describe the prevalence of retinal vascular signs and their association with cardiovascular risk factors in a Japanese population. Population-based cross-sectional study. Adult persons aged 35 years or older from Funagata, Yamagata Prefecture, Japan (n = 1481). The Funagata Study is a Japanese population-based study of persons aged 35 years or older, and included 1961 nondiabetic participants (53.3% of 3676 eligible subjects). A nonmydriatic retinal photograph was taken of 1 eye to assess retinal microvascular signs. Retinal arteriolar wall signs (focal arteriolar narrowing, arteriovenous nicking, enhanced arteriolar wall reflex) and retinopathy were assessed in 1481 participants without diabetes (40.3% of eligible persons) using a standardized protocol. Using a computer-assisted method, retinal vessel diameters were measured in 921 participants with gradable retinal image (25.1% of eligible persons). Prevalence of retinal microvascular signs and their association with cardiovascular risk factors. Moderate or severe focal arteriolar narrowing, arteriovenous nicking, enhanced arteriolar wall reflex, and retinopathy were found in 8.3%, 15.2%, 18.7%, and 9.0%, respectively, of the study population. Mean (+/-standard error) values for retinal arteriolar diameter were 178.6+/-21.0 mum, and mean values (+/-standard error) for venular diameter were 214.9+/-20.6 mum. Older persons were more likely to have retinal arteriolar wall signs, retinopathy, and narrower retinal vessel diameters. After adjusting for multiple factors, each 10-mmHg increase in mean arterial blood pressure was associated with a 20% to 40% increased likelihood of retinal arteriolar signs and a 2.8-mum reduction in arteriolar diameter. Retinopathy was associated with higher body mass index and both impaired glucose tolerance and impaired fasting glucose. In nondiabetic Japanese adults, retinal arteriolar wall signs were associated with older age and increased blood pressure, whereas retinopathy was associated with older age, higher body mass index, impaired glucose tolerance, and impaired fasting glucose. These findings are comparable with data from white populations.

  19. In situ hybridization evidence for the coexistence of ASIC and TRPV1 within rat single sensory neurons.

    PubMed

    Ugawa, Shinya; Ueda, Takashi; Yamamura, Hisao; Shimada, Shoichi

    2005-05-20

    The activation of nociceptors by protons plays a crucial role in the initiation and maintenance of acidosis-linked pain. Acid-sensing ion channel (ASIC) and transient receptor potential/vanilloid receptor subtype-1 (TRPV1) encode proton-activated cation channels expressed by nociceptors and the opening of these channels results in nociceptor excitation. Histological relations among ASIC clones and the colocalization of each ASIC subunit and TRPV1 within single sensory neurons were examined on serial sections of rat dorsal root ganglia (DRG) using in situ hybridization histochemistry. ASIC1a transcripts were expressed in 20-25% of the DRG neurons, and most of the neurons had small (<30 microm)-diameter cell bodies. ASIC1b transcripts and ASIC3 transcripts were expressed in approximately 10% and 30-35% of the DRG neurons, respectively, and the greater part of each population was located in small-to-medium (30-50 microm)-diameter cells. The ASIC1a transcripts and ASIC1b transcripts were basically localized in the distinct populations of the DRG neurons, while approximately 20% of the ASIC1a-positive neurons and approximately 10% of the ASIC1b-positive neurons expressed ASIC3 transcripts. TRPV1 transcripts were expressed in 35-40% of the DRG neurons, and most of the TRPV1-positive neurons had small-diameter cell bodies. Intense expression signals for ASIC1a transcripts were detected in 40-45% of the TRPV1-positive neurons. Neurons expressing both ASIC1b and TRPV1 transcripts were barely detected in the DRG. Approximately 30% of the TRPV1-positive neurons expressed ASIC3 transcripts, and the double-labeled neurons were comprised of both small-diameter and medium-diameter cells. Approximately 13% of the TRPV1-positive neurons expressed both ASIC1a and ASIC3 transcripts.

  20. JACKETED FISSIONABLE MEMBER

    DOEpatents

    Boller, E.R.; Robinson, J.W.

    1960-09-13

    A fuel element design for a nuclear reactor is presented. The fuel element comprises a cylindrical fuel body having a portion of smaller diameter at each end thereof with an annular flange at the extreme ends of these portions of smaller diameter. An end cap fits over the ends of the fuel body and has an internal annular groove adapted to receive the flange. The fuel body and end caps are disposed in a cup-shaped jacket, a closure disc completing the enclosure of the fuel body, and tht caps are bonded over their entire periphery to the jacket.

  1. Analysis of localised dose distribution in human body by Monte Carlo code system for photon irradiation.

    PubMed

    Ohnishi, S; Odano, N; Nariyama, N; Saito, K

    2004-01-01

    In usual personal dosimetry, whole body irradiation is assumed. However, the opportunity of partial irradiation is increasing and the tendencies of protection quantities caused under those irradiation conditions are different. The code system has been developed and effective dose and organ absorbed doses have been calculated in the case of horizontal narrow photon beam irradiated from various directions at three representative body sections, 40, 50 and 60 cm originating from the top of the head. This work covers 24 beam directions, each 15 degrees angle ranging from 0 degrees to 345 degrees, three energy levels, 45 keV, 90 keV and 1.25 MeV, and three beam diameters of 1, 2 and 4 cm. These results show that the beam injected from diagonally front or other specific direction causes peak dose in the case of partial irradiation.

  2. Coronary artery dimensions in normal Indians.

    PubMed

    Raut, Barendra Kumar; Patil, Vijaysinh Namdeo; Cherian, George

    Diameter of coronary artery is an important predictor of outcome after percutaneous coronary interventions and coronary artery bypass graft surgery. There is very limited data available about coronary artery dimensions in an Indian population. To study the normal dimensions of the coronary artery segments in Indians without coronary artery disease by using quantitative coronary angiography and also to compare the dimensions in Indians with Western. 229 patients who have undergone coronary angiography with entirely normal coronary angiogram were included in our study. This study showed the diameter of vessels in males and females when taken together the left main was larger in size followed by proximal LAD, proximal RCA & proximal LCX respectively (4.08±0.44mm, 3.27±0.23mm, 3.20±0.37mm, 2.97±0.37mm).When the vessel diameter was indexed to body surface area there was no statistical difference between male and female (p value>0.05). The computed value of proximal coronary artery diameter unadjusted for individual body surface area, when compared to Caucasians showed that Caucasians have larger coronary artery dimensions than Indians. But when the proximal vessel diameter was indexed to body surface area there was no statistical significant difference between Indians and Caucasians (p value>0.05). We found that coronary artery size when indexed to body surface area is not statistically different in Indian males and females and compared to Caucasians. However with a smaller body habitus Indians have smaller coronary arteries. Copyright © 2017. Published by Elsevier B.V.

  3. Method for fabricating thin californium-containing radioactive source wires

    DOEpatents

    Gross, Ian G; Pierce, Larry A

    2006-08-22

    A method for reducing the cross-sectional diameter of a radioactive californium-containing cermet wire while simultaneously improving the wire diameter to a more nearly circular cross section. A collet fixture is used to reduce the wire diameter by controlled pressurization pulses while simultaneously improving the wire cross-sectional diameter. The method is especially suitable for use in hot cells for the production of optimized cermet brachytherapy sources that contain large amounts of radioactive californium-252.

  4. In Utero Exposure to Di( n-butyl)phthalate Induces Morphological and Biochemical Changes in Rats Postpuberty.

    PubMed

    Okayama, Yuya; Wakui, Shin; Wempe, Michael F; Sugiyama, Mitsuru; Motohashi, Masaya; Mutou, Tomoko; Takahashi, Hiroyuki; Kume, Eisuke; Ikegami, Hiroshi

    2017-06-01

    Pregnant Sprague-Dawley rats were orally administered di( n-butyl)phthalate (DBP; 100 mg/kg/day) on gestation days (GD) 12 to 21. We investigated the male offspring and probed morphological alterations in Sertoli cells at 7, 9, 14, and 17 weeks of age. Parameters assessed in this study included offspring number, sex ratios, body weights, testis weights, seminiferous tubule (ST) profile numbers and diameters, number of vimentin-labeled Sertoli cells, and both testosterone and follicle-stimulating hormone (FSH) levels. Testicular weight/body weight ratios and the numbers and diameters of ST in maximum transverse testicular sections were statistically similar at weeks 7 and 9; however, at weeks 14 and 17, they were statistically different and displayed higher BrdU-positive Sertoli cells/Sertoli cell ratios in the DBP treatment group. Noteworthily, the serum FSH levels were higher and testicular testosterone levels were lower in the DBP treatment group. To our knowledge, the present study is the first to report that in utero DBP exposure significantly increased Sertoli cell numbers and their cellular proliferation from postpuberty to adulthood, with a significant decrease in testicular testosterone and an increase in FSH.

  5. Superconducting cable connections and methods

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    van der Laan, Daniel Cornelis

    2017-09-05

    Superconducting cable connector structures include a terminal body (or other structure) onto which the tapes from the superconducting cable extend. The terminal body (or other structure) has a diameter that is sufficiently larger than the diameter of the former of the superconducting cable, so that the tapes spread out over the outer surface of the terminal body. As a result, gaps are formed between tapes on the terminal body (or other structure). Those gaps are filled with solder (or other suitable flowable conductive material), to provide a current path of relatively high conductivity in the radial direction. Other connector structuresmore » omit the terminal body.« less

  6. A correlation method to predict the surface pressure distribution of an infinite plate or a body of revolution from which a jet is issuing

    NASA Technical Reports Server (NTRS)

    Perkins, S. C., Jr.; Mendenhall, M. R.

    1980-01-01

    A correlation method to predict pressures induced on an infinite plate by a jet exhausting normal to the plate into a subsonic free stream was extended to jets exhausting at angles to the plate and to jets exhausting normal to the surface of a body revolution. The complete method consisted of an analytical method which models the blockage and entrainment properties of the jet and an empirical correlation which accounts for viscous effects. For the flat plate case, the method was applicable to jet velocity ratios up to ten, jet inclination angles up to 45 deg from the normal, and radial distances up to five diameters from the jet. For the body of revolution case, the method was applicable to a body at zero degrees angle of attack, jet velocity ratios 1.96 and 3.43, circumferential angles around the body up to 25 deg from the jet, axial distances up to seven diameters from the jet, and jet-to-body diameter ratios less than 0.1.

  7. Identification of a Common R-Chondrite Impactor on the Ureilite Parent Body

    NASA Technical Reports Server (NTRS)

    Downes, H.; Mittlefehldt, D. W.

    2006-01-01

    Polymict ureilites are brecciated ultramafic meteorites that contain a variety of single mineral and lithic clasts. They represent the surface debris from a small, differentiated asteroid. We are continuing a detailed petrological study of several polymict ureilites including EET 87720, EET 83309 and FRO93008 (from Antarctica), North Haig, Nilpena (Australia), DaG 976, DaG 999, DaG 1000 and DaG 1023 (Libya). The latter four stones are probably paired. Clast sizes can be 10 mm in diameter, so a thin-section can consist of a single lithic clast.

  8. Investigation of Some Wake Vortex Characteristics of an Inclined Ogive-Cylinder Body at Mach Number 2

    NASA Technical Reports Server (NTRS)

    Jorgensen, Leland H; Perkins, Edward W

    1958-01-01

    For a body consisting of a fineness-ratio-3 ogival nose tangent to a cylindrical afterbody 7.3 diameters long, pitot-pressure distributions in the flow field, pressure distributions over the body, and downwash distributions along a line through the vortex centers have been measured for angles of attack to 20 degrees. The Reynolds numbers, based on body diameter, were 0.15 x 10 to the 6th power and 0.44 x 10 to the 6th power. Comparisons of computed and measured vortex paths and downwash distributions are made. (author)

  9. The Probable Ages of Asteroid Families

    NASA Technical Reports Server (NTRS)

    Harris, A. W.

    1993-01-01

    There has been considerable debate recently over the ages of the Hirayama families, and in particular if some of the families are very oung(u) It is a straightforward task to estimate the characteristic time of a collision between a body of a given diameter, d_o, by another body of diameter greater of equal to d_1. What is less straightforward is to estimate the critical diameter ratio, d_1/d_o, above which catastrophic disruption occurs, from which one could infer probable ages of the Hirayama families, by knowing the diameter of the parent body, d_o. One can gain some insight into the probable value of d_1/d_o, and of the likely ages of existing families, from the plot below. I have computed the characteristic time between collisions in the asteroid belt of a size ratio greater of equal to d_1/d_o, for 4 sizes of target asteroids, d_o. The solid curves to the lower right are the characteristic times for a single object...

  10. Comparative Evaluation of Fracture Resistance and Mode of Failure of Zirconia and Titanium Abutments with Different Diameters.

    PubMed

    Shabanpour, Reza; Mousavi, Niloufar; Ghodsi, Safoura; Alikhasi, Marzieh

    2015-08-01

    The purpose of the current study was to compare the fracture resistance and mode of failure of zirconia and titanium abutments with different diameters. Fourteen groups of abutments including prefabricated zirconia, copy-milled zirconia and titanium abutments of an implant system (XiVE, Dentsply) were prepared in different diameters. An increasing vertical load was applied to each specimen until failure occurred. Fracture resistance was measured in each group using the universal testing machine. Moreover, the failure modes were studied and categorized as abutment screw fracture, connection area fracture, abutment body fracture, abutment body distortion, screw distortion and connection area distortion. Groups were statistically compared using univariate and post-hoc tests. The level of statistical significance was set at 5%. Fabrication method (p = 0.03) and diameter (p < 0.001) had significant effect on the fracture resistance of abutments. Fracture resistance of abutments with 5.5 mm diameter was higher than other diameters (p < 0.001). The observed modes of failure were dependent on the abutment material as well. All of the prefabricated titanium abutments fractured within the abutment screw. Abutment screw distortion, connection area fracture, and abutment body fracture were the common failure type in other groups. Diameter had a significant effect on fracture resistance of implant abutments, as abutments with greater diameters were more resistant to static loads. Copy-milled abutments showed lower fracture resistance as compared to other experimental groups. Although zirconia abutments have received great popularity among clinicians and even patients selecting them for narrow implants should be with caution.

  11. Experimental wake survey behind a 140 deg-included-angle cone at angles of attack of 0 deg and 5 deg, Mach numbers from 1.60 to 3.95, and longitudinal stations varying from 1.0 to 8.39 body diameters

    NASA Technical Reports Server (NTRS)

    Brown, C. A., Jr.; Campbell, J. F.

    1971-01-01

    The flow properties in the wake of a 140 deg-included-angle cone at Mach numbers from 1.60 to 3.95 and at angles of attack of 0 deg and 5 deg are discussed. The wake flow properties are calculated from total and static pressures measured with a pressure rake at longitudinal stations varying from 1.0 to 8.39 body diameters and at lateral stations varying from -0.42 to 3.0 body diameters. These measurements show a consistent trend throughout the range of Mach number and longitudinal distance and an increase in dynamic pressure with increasing longitudinal station.

  12. Experimental wake survey behind Viking 1975 entry vehicle at angles of attack of 0 deg and 5 deg, Mach numbers from 1.60 to 3.95, and longitudinal stations from 1.0 to 8.39 body diameters

    NASA Technical Reports Server (NTRS)

    Brown, C. A., Jr.; Campbell, J. F.; Tudor, D. H.

    1971-01-01

    An investigation was conducted to obtain flow properties in the wake of the Viking '75 entry vehicle at Mach numbers from 1.60 to 3.95 and at angles of attack of 0 deg and 5 deg. The wake flow properties were calculated from total and static pressures measured with a pressure rake at longitudinal stations varying from 1.0 to 8.39 body diameters and lateral stations varying from -0.42 to 3.0 body diameters. These measurements showed a a consistent trend throughout the range of Mach numbers and longitudinal distances and an increase in dynamic pressure with increasing downstream position.

  13. Anatomic features of the cetacean globe.

    PubMed

    Miller, Sarah; Samuelson, Don; Dubielzig, Richard

    2013-07-01

    To provide measurements of globe dimensions and describe morphological characteristics of the cetacean globe with an emphasis on Bowman's layer and encapsulated sensory corpuscles (ESC) for available cetacean species. Cetacean globes housed at the Comparative Ocular Pathology Laboratory of Wisconsin from various odontocete and two mysticete species. Measurements were taken from formalin fixed globes and images of formalin fixed globes with embedded rulers. Histological sections of globes were used to count ESC and measure Bowman's layer. The horizontal diameter of the globe was longer than the vertical diameter. The posterior sclera was thick, causing the internal axial length (and therefore the optical axis) to be shorter than the vertical diameter. The cornea was composed of an epithelium, Bowman's layer, collagenous stroma, thin Descemet's membrane and endothelial layer. Bowman's layer was present in all specimens except one Kogia breviceps. The thickness was variable, with the acellular layer thickest in Tursiops truncatus and thinnest in Kogia sp. The iris was well vascularized and muscled while the ciliary body lacked musculature, but retained vasculature. Single and clustered ESC were found in the anterior uvea, sclera surrounding the anterior uvea, trabecular meshwork, or some combination of these locations. They were often regionally grouped and varied from 0 to 21. There were three species where no ESC were found, L. borealis, D. capensis, and S. bredanensis, but the presence of these corpuscles cannot be ruled as only one section of the globe was analyzed. © 2013 American College of Veterinary Ophthalmologists.

  14. Impact simulation in the gravity regime: Exploring the effects of parent body size and internal structure

    NASA Astrophysics Data System (ADS)

    Benavidez, P. G.; Durda, D. D.; Enke, B.; Campo Bagatin, A.; Richardson, D. C.; Asphaug, E.; Bottke, W. F.

    2018-04-01

    In this work we extend the systematic investigation of impact outcomes of 100-km-diameter targets started by Durda et al. (2007) and Benavidez et al. (2012) to targets of D = 400 km using the same range of impact conditions and two internal structures: monolithic and rubble-pile. We performed a new set of simulations in the gravity regime for targets of 400 km in diameter using these same internal structures. This provides a large set of 600 simulations performed in a systematic way that permits a thorough analysis of the impact outcomes and evaluation of the main features of the size frequency distribution due mostly to self-gravity. In addition, we use the impact outcomes to attempt to constrain the impact conditions of the asteroid belt where known asteroid families with a large expected parent body were formed. We have found fairly good matches for the Eunomia and Hygiea families. In addition, we identified a potential acceptable match to the Vesta family from a monolithic parent body of 468 km. The impact conditions of the best matches suggest that these families were formed in a dynamically excited belt. The results also suggest that the parent body of the Eunomia family could be a monolithic body of 382 km diameter, while the one for Hygiea could have a rubble-pile internal structure of 416 km diameter.

  15. Atmospheric breakup of a small comet in the Earth's atmosphere

    NASA Technical Reports Server (NTRS)

    Teterev, A. V.; Misychenko, N. I.; Rudak, L. V.; Romanov, G. S.; Smetannikov, A. S.; Nemchinov, I. V.

    1993-01-01

    The aerodynamic stresses can lead to the deformation and even to destruction of the meteoroids during their flight through the atmosphere. The pressure at the blunt nose of the cosmic body moving at very high speed through the dense layers of the atmosphere may be much larger than the tensile or the compressive strength of the body. So the usage of the hydrodynamics theory is validated. The estimates show that the transverse velocity of the substance of the body U is of the order of (rho(sub a)/rho(sub o))(sup 1/2)V where V is the velocity of the body and rho(sub o) is its density, rho(sub a) is the density of the atmosphere. The separation of the fragments is larger than the diameter of the body D if D is less than D(sub c) = 2H(square root of rho(sub a)/rho(sub o)), where H is the characteristic scale of the atmosphere. For an icy body one obtains U = 1/30(V) and critical diameter D(sub C) = 500 m. The process of the disintegration of the body is still not fully understood and so one can use the numerical simulation to investigate it. Such simulations where conducted for the Venusian atmosphere and the gaseous equation of state of the body was used. For the Earth atmosphere for the velocity V = 50 km/s the pressure at the blunt nose of the body is 25 kbar, and is of the order of bulk modulus of compressibility of the water or ice. The realistic EOS of water in tabular form was used. It was assumed that the initial shape of the body was spherical and the initial diameter D(sub o) of the body is 200 m and so it is smaller than the critical diameter D(sub C). The initial kinetic energy of the icy body is equivalent to the energy of the explosion 1200 Mt of TNT. The results of the simulation of the deformation of the body during its vertical flight through the atmosphere and during its impact into the ocean are presented.

  16. Classification of Kiwifruit Grades Based on Fruit Shape Using a Single Camera

    PubMed Central

    Fu, Longsheng; Sun, Shipeng; Li, Rui; Wang, Shaojin

    2016-01-01

    This study aims to demonstrate the feasibility for classifying kiwifruit into shape grades by adding a single camera to current Chinese sorting lines equipped with weight sensors. Image processing methods are employed to calculate fruit length, maximum diameter of the equatorial section, and projected area. A stepwise multiple linear regression method is applied to select significant variables for predicting minimum diameter of the equatorial section and volume and to establish corresponding estimation models. Results show that length, maximum diameter of the equatorial section and weight are selected to predict the minimum diameter of the equatorial section, with the coefficient of determination of only 0.82 when compared to manual measurements. Weight and length are then selected to estimate the volume, which is in good agreement with the measured one with the coefficient of determination of 0.98. Fruit classification based on the estimated minimum diameter of the equatorial section achieves a low success rate of 84.6%, which is significantly improved using a linear combination of the length/maximum diameter of the equatorial section and projected area/length ratios, reaching 98.3%. Thus, it is possible for Chinese kiwifruit sorting lines to reach international standards of grading kiwifruit on fruit shape classification by adding a single camera. PMID:27376292

  17. Evaluation of normal abdominal aortic diameters in the Indian population using computed tomography.

    PubMed

    Jasper, A; Harshe, G; Keshava, S N; Kulkarni, G; Stephen, E; Agarwal, S

    2014-01-01

    The aim of this study was to establish normal diameters for the suprarenal and infrarenal abdominal aorta measured at T12 and L3 vertebral levels in the Indian population and to study the variation in aortic diameters with age, sex, height, weight, body mass index (BMI), and body surface area (BSA). One hundred and forty-two patients who underwent helical contrast-enhanced computed tomography (CT) scans of the abdomen for non-cardiovascular reasons were recruited.. The mean internal diameters of the suprarenal and infrarenal abdominal aorta (maximum anteroposterior and transverse diameter) were measured at T12 and L3 vertebral levels and tabulated according to various age groups for both men and women. Pearson correlation coefficient was used to evaluate the correlation between aortic diameters, height, weight, BSA, and BMI. The mean diameters of the suprarenal and infrarenal abdominal aorta measured at T12 and L3 vertebral levels, in men were 19.0 ± 2.3 and 13.8 ± 1.9 mm and in women 17.1 ± 2.3 and 12.0 ± 1.6 mm, respectively. The aortic diameter progressively increased in caliber with increasing age of the patients and was smaller in women than men. A significant positive correlation was found in men between the suprarenal and infrarenal aortic diameters and weight, BSA, and BMI. In women, this correlation was significant in the infrarenal aorta but not in the suprarenal aorta. We obtained a set of normal values for the abdominal aorta in the Indian population. The aortic diameters correlated with age, gender, and body size of the patients as seen with previously published data in the Western population. A brief comparison of data between Indian and Western population showed that the values obtained were less than published elsewhere and hence, this should be considered while formulating intervention protocols.

  18. Effects of Hypergravity on Statocyst Development in Embryonic Aplysia californica

    NASA Technical Reports Server (NTRS)

    Pedrozo, Hugo A.; Wiederhold, Michael L.

    1994-01-01

    Aplysia californica is a marine gastropod mollusc with bilaterally paired statocysts as gravity-reccptor organs. Data from three experiments in which embryonic Aplysia californica were exposed to 2 x g arc discussed. The experimental groups were exposed to excess gravity until hatching (9-12 day), whereas control groups were maintained at normal gravity. Body diameter was measured before exposure to 2 x g. Statocyst, statolith and body diameter were each determined for samples of 20 embryos from each group on successive days. Exposure to excess gravity led to an increase in body size. Statocyst size was not affected by exposure to 2 x g. Statolith size decreased with treatment as indicated by smaller statolith-to-body ratios observed in the 2 x g group in all three experiments. Mean statolith diameter was significantly smaller for the 2 x g group in Experiment 1 but not in Experiments 2 and 3. Defective statocysts, characterized by very small or no statoliths, were found in the 2 x g group in Experiments 1 and 2.

  19. Resinless section electron microscopy reveals the yeast cytoskeleton.

    PubMed

    Penman, J; Penman, S

    1997-04-15

    The cytoskeleton of Saccharomyces cerevisiae is essentially invisible using conventional microscopy techniques. A similar problem was solved for the mammalian cell cytoskeleton using resinless section electron microscopy, a technique applied here to yeast. In the resinless image, soluble proteins are no longer cloaked by embedding medium and must be removed by selective detergent extraction. In yeast, this requires breaching the cell wall by digesting with Zymolyase sufficiently to allow detergent extraction of the plasma membrane lipids. Gel electropherograms show that the extracted or "soluble" proteins are distinct from the retained or "structural" proteins that presumably comprise the cytoskeleton. These putative cytoskeleton proteins include the major portions of a 43-kDa protein, which is presumably actin, and of proteins in a band appearing at 55 kDa, as well as numerous less abundant, nonactin proteins. Resinless section electron micrographs show a dense, three-dimensional web of anastomosing, polymorphic filaments bounded by the remnant cell wall. Although the filament network is very heterogenous, there appear to be two principal classes of filament diameters-5 nm and 15-20 nm-which may correspond to actin and intermediate filaments, respectively. A large oval region of lower filament density probably corresponds to the vacuole, and an electron dense spheroidal body, 300-500 nm in diameter, is likely the nucleus. The techniques detailed in this report afford new approaches to the study of yeast cytoarchitecture.

  20. Evaluation of pulsatility index and diameter of the jugular vein and superficial body temperature as physiological indices of temperament in weaned beef calves: relationship with serum cortisol concentrations, rectal temp..

    USDA-ARS?s Scientific Manuscript database

    The relationship between temperament, pulsatility index and diameter of the jugular vein, and body temperature was assessed in Angus crossbred calves (262±24.9 days old). Temperament scores were used to classify calves as calm (n=31), intermediate (n=32), or temperamental (n=28). Blood samples were ...

  1. Monocoque structure for the SKITTER three-legged walker

    NASA Technical Reports Server (NTRS)

    Bansek, Robert N.; Booth, Andrew J.; Daneman, Steven A.; Dresser, James A.; Haney, Todd G.; Johnson, Gregory R.; Lindzen, Eric C.; Montgomery, Robert C.; Warren, Andrew L.

    1988-01-01

    The SKITTER 2 design is a monocoque version of the proposed lunar three-legged walker. By the definition of monocoque, the body and legs are a shell with no internal ribbing or supports added for absorbing stresses. The purpose of the monocoque is to encase the elements used for power transmission, power supply, and control of the motion. The material for the structure is a vinyl ester resin, Derakane 8084. This material is easily formable and locally obtainable. The body consists of a hexagonally shaped cylinder with truncated hexagonal pyramids on the top and botton. The legs are eight inch diameter cylinders. The legs are comprised of a tibia section and a femur section. The SKITTER 2 is powered by six actuators which provide linear forces that are transformed into rotary torques by a series of chains and sprockets. The joints connect the femur to the body and the tibia to the femur. Surrounding the joints are flexible rubber hoses that fully encase the chains and sprockets. The SKITTER 2 is capable of walking upside down, righting itself after being overturned, and has the ability to perform in many environments. Applications for this walker include lunar transport or drilling, undersea exploration, and operation in severe surroundings such as arctic temperatures or high radiation.

  2. Monocoque structure for the SKITTER three-legged walker

    NASA Astrophysics Data System (ADS)

    Bansek, Robert N.; Booth, Andrew J.; Daneman, Steven A.; Dresser, James A.; Haney, Todd G.; Johnson, Gregory R.; Lindzen, Eric C.; Montgomery, Robert C.; Warren, Andrew L.

    1988-06-01

    The SKITTER 2 design is a monocoque version of the proposed lunar three-legged walker. By the definition of monocoque, the body and legs are a shell with no internal ribbing or supports added for absorbing stresses. The purpose of the monocoque is to encase the elements used for power transmission, power supply, and control of the motion. The material for the structure is a vinyl ester resin, Derakane 8084. This material is easily formable and locally obtainable. The body consists of a hexagonally shaped cylinder with truncated hexagonal pyramids on the top and botton. The legs are eight inch diameter cylinders. The legs are comprised of a tibia section and a femur section. The SKITTER 2 is powered by six actuators which provide linear forces that are transformed into rotary torques by a series of chains and sprockets. The joints connect the femur to the body and the tibia to the femur. Surrounding the joints are flexible rubber hoses that fully encase the chains and sprockets. The SKITTER 2 is capable of walking upside down, righting itself after being overturned, and has the ability to perform in many environments. Applications for this walker include lunar transport or drilling, undersea exploration, and operation in severe surroundings such as arctic temperatures or high radiation.

  3. Topographical distribution and morphology of NADPH-diaphorase-stained neurons in the human claustrum

    PubMed Central

    Hinova-Palova, Dimka V.; Edelstein, Lawrence; Landzhov, Boycho; Minkov, Minko; Malinova, Lina; Hristov, Stanislav; Denaro, Frank J.; Alexandrov, Alexandar; Kiriakova, Teodora; Brainova, Ilina; Paloff, Adrian; Ovtscharoff, Wladimir

    2014-01-01

    We studied the topographical distribution and morphological characteristics of NADPH-diaphorase-positive neurons and fibers in the human claustrum. These neurons were seen to be heterogeneously distributed throughout the claustrum. Taking into account the size and shape of stained perikarya as well as dendritic and axonal characteristics, Nicotinamide adenine dinucleotide phosphate-diaphorase (NADPHd)-positive neurons were categorized by diameter into three types: large, medium and small. Large neurons ranged from 25 to 35 μm in diameter and typically displayed elliptical or multipolar cell bodies. Medium neurons ranged from 20 to 25 μm in diameter and displayed multipolar, bipolar and irregular cell bodies. Small neurons ranged from 14 to 20 μm in diameter and most often displayed oval or elliptical cell bodies. Based on dendritic characteristics, these neurons were divided into spiny and aspiny subtypes. Our findings reveal two populations of NADPHd-positive neurons in the human claustrum—one comprised of large and medium cells consistent with a projection neuron phenotype, the other represented by small cells resembling the interneuron phenotype as defined by previous Golgi impregnation studies. PMID:24904317

  4. Change in human lens dimensions, lens refractive index distribution and ciliary body ring diameter with accommodation.

    PubMed

    Khan, Adnan; Pope, James M; Verkicharla, Pavan K; Suheimat, Marwan; Atchison, David A

    2018-03-01

    We investigated changes in ciliary body ring diameter, lens dimensions and lens refractive index distributions with accommodation in young adults. A 3T clinical magnetic resonance imaging scanner imaged right eyes of 38 18-29 year old participants using a multiple spin echo sequence to determine accommodation-induced changes along lens axial and equatorial directions. Accommodation stimuli were approximately 1 D and 5 D. With accommodation, ciliary body ring diameter, and equatorial lens diameter decreased (-0.43 ± 0.31 mm and -0.30 ± 0.23 mm, respectively), and axial lens thickness increased ( + 0.34 ± 0.16 mm). Lens shape changes cause redistribution of the lens internal structure, leading to change in refractive index distribution profiles. With accommodation, in the axial direction refractive index profiles became flatter in the center and steeper near the periphery of the lens, while in the equatorial direction they became steeper in the center and flatter in the periphery. The results suggest that the anatomical accuracy of lens optical models can be improved by accounting for changes in the refractive index profile during accommodation.

  5. Pipe support for use in a nuclear system

    DOEpatents

    Pollono, Louis P.; Mello, Raymond M.

    1977-01-01

    A pipe support for high temperature, thin-walled vertical piping runs used in a nuclear system. A cylindrical pipe transition member, having the same inside diameter as the thin-walled piping, replaces a portion of the piping where support is desired. The outside diameter of the pipe transition member varies axially along its vertical dimension. For a section of the axial length adjacent the upper and lower terminations of the pipe transition member, the outside diameter is the same as the outside diameter of the thin-walled piping to which it is affixed. Intermediate of the termination sections, the outside diameter increases from the top of the member to the bottom. Adjacent the lower termination section, the diameter abruptly becomes the same as the piping. Thus, the cylindrical transition member is formed to have a generally triangular shaped cross-section along the axial dimension. Load-bearing insulation is installed next to the periphery of the member and is kept in place by an outer ring clamp. The outer ring clamp is connected to pipe hangers, which provide the desired support for the vertical thin-walled piping runs.

  6. [Research report of experimental database establishment of digitized virtual Chinese No.1 female].

    PubMed

    Zhong, Shi-zhen; Yuan, Lin; Tang, Lei; Huang, Wen-hua; Dai, Jing-xing; Li, Jian-yi; Liu, Chang; Wang, Xing-hai; Li, Hua; Luo, Shu-qian; Qin, Dulie; Zeng, Shao-qun; Wu, Tao; Zhang, Mei-chao; Wu, Kun-cheng; Jiao, Pei-feng; Lu, Yun-tao; Chen, Hao; Li, Pei-liang; Gao, Yuan; Wang, Tong; Fan, Ji-hong

    2003-03-01

    To establish digitized virtual Chinese No.1 female (VCH-F1) image database. A 19 years old female cadaver was scanned by CT, MRI, and perfused with red filling material through formal artery before freezing and em- bedding. The whole body was cut by JZ1500A vertical milling machine with a 0.2 mm inter-spacing. All the images was produced by Fuji FinePix S2 Pro camera. The body index of VCH-F1 was 94%. We cut 8 556 sections of the whole body, and each image was 17.5 MB in size and the whole database reached 149.7 GB. We have totally 6 versions of the database for different applications. Compared with other databases, VCH-F1 has good representation of the Chinese body shape, colorful filling material in blood vessels providing enough information for future registration and segmentation. Vertical embedding and cutting helped to retain normal human physiological posture, and the image quality and operation efficiency were improved by using various techniques such as one-time freezing and fixation, double-temperature icehouse, large-diameter milling disc and whole body cutting.

  7. A comparison study of size-specific dose estimate calculation methods.

    PubMed

    Parikh, Roshni A; Wien, Michael A; Novak, Ronald D; Jordan, David W; Klahr, Paul; Soriano, Stephanie; Ciancibello, Leslie; Berlin, Sheila C

    2018-01-01

    The size-specific dose estimate (SSDE) has emerged as an improved metric for use by medical physicists and radiologists for estimating individual patient dose. Several methods of calculating SSDE have been described, ranging from patient thickness or attenuation-based (automated and manual) measurements to weight-based techniques. To compare the accuracy of thickness vs. weight measurement of body size to allow for the calculation of the size-specific dose estimate (SSDE) in pediatric body CT. We retrospectively identified 109 pediatric body CT examinations for SSDE calculation. We examined two automated methods measuring a series of level-specific diameters of the patient's body: method A used the effective diameter and method B used the water-equivalent diameter. Two manual methods measured patient diameter at two predetermined levels: the superior endplate of L2, where body width is typically most thin, and the superior femoral head or iliac crest (for scans that did not include the pelvis), where body width is typically most thick; method C averaged lateral measurements at these two levels from the CT projection scan, and method D averaged lateral and anteroposterior measurements at the same two levels from the axial CT images. Finally, we used body weight to characterize patient size, method E, and compared this with the various other measurement methods. Methods were compared across the entire population as well as by subgroup based on body width. Concordance correlation (ρ c ) between each of the SSDE calculation methods (methods A-E) was greater than 0.92 across the entire population, although the range was wider when analyzed by subgroup (0.42-0.99). When we compared each SSDE measurement method with CTDI vol, there was poor correlation, ρ c <0.77, with percentage differences between 20.8% and 51.0%. Automated computer algorithms are accurate and efficient in the calculation of SSDE. Manual methods based on patient thickness provide acceptable dose estimates for pediatric patients <30 cm in body width. Body weight provides a quick and practical method to identify conversion factors that can be used to estimate SSDE with reasonable accuracy in pediatric patients with body width ≥20 cm.

  8. Fractal Characteristics of the Pore Network in Diatomites Using Mercury Porosimetry and Image Analysis

    NASA Astrophysics Data System (ADS)

    Stańczak, Grażyna; Rembiś, Marek; Figarska-Warchoł, Beata; Toboła, Tomasz

    The complex pore space considerably affects the unique properties of diatomite and its significant potential for many industrial applications. The pore network in the diatomite from the Lower Miocene strata of the Skole nappe (the Jawornik deposit, SE Poland) has been investigated using a fractal approach. The fractal dimension of the pore-space volume was calculated using the Menger sponge as a model of a porous body and the mercury porosimetry data in a pore-throat diameter range between 10,000 and 10 nm. Based on the digital analyses of the two-dimensional images from thin sections taken under a scanning electron microscope at the backscattered electron mode at different magnifications, the authors tried to quantify the pore spaces of the diatomites using the box counting method. The results derived from the analyses of the pore-throat diameter distribution using mercury porosimetry have revealed that the pore space of the diatomite has the bifractal structure in two separated ranges of the pore-throat diameters considerably smaller than the pore-throat sizes corresponding to threshold pressures. Assuming that the fractal dimensions identified for the ranges of the smaller pore-throat diameters characterize the overall pore-throat network in the Jawornik diatomite, we can set apart the distribution of the pore-throat volume (necks) and the pore volume from the distribution of the pore-space volume (pores and necks together).

  9. Comparison of experimental and theoretical normal-force distributions (including Reynolds number effects) on an ogive-cylinder body at Mach number 1.98

    NASA Technical Reports Server (NTRS)

    Perkins, Edward W; Jorgensen, Leland H

    1956-01-01

    Effects of Reynolds number and angle of attack on the pressure distribution and normal-force characteristics of a body of revolution consisting of a fineness ratio 3 ogival nose tangent to a cylindrical afterbody 7 diameters long have been determined. The test Mach number was 1.98 and the angle-of-attack range from 0 degree to 20 degrees. The Reynolds numbers, based on body diameter, were 0.15 x 10(6) and 0.45 x 10(6). The experimental results are compared with theory.

  10. Injector for use in high voltage isolators for liquid feed lines

    NASA Technical Reports Server (NTRS)

    Snyder, J. A. (Inventor)

    1973-01-01

    An improved injector is described for use in introducing fluid substances into feed lines employed in delivering flowing bodies of liquids. The injector includes a porous plug, concentrically related to a feed line, including an internally tapered surface of a truncated conical configuration with an inlet orifice of a first diameter substantially smaller than the first diameter and an external surface circumscribed by an annular chamber containing a body of insulating gas.

  11. Tracheole investment does not vary with body size among bumblebee (Bombus impatiens) sisters.

    PubMed

    Vogt, Jessica R; Dillon, Megan K; Dillon, Michael E

    2014-08-01

    Body size is a key organism trait with critical implications for the physiology, life history, and ecology of organisms. Modern insects vary in body mass by over 6 orders of magnitude, but are small by comparison to many other metazoan taxa. The small size of modern insects may reflect limitations imposed by their open respiratory systems which rely, in part, on diffusion. Diffusion rates decline with distance such that, absent compensation, the capacity for larger insects to deliver oxygen to their tissues may be compromised. To compensate, larger grasshoppers, beetles, and bumblebees devote proportionally more of their body volume to the respiratory system, as demonstrated by hypermetric scaling of tracheal volume with body mass(>1). Among bumblebee sisters, total respiratory volume scaled with mass(2.6), but it is unclear at what level or levels of the tracheal system (main tracheal trunks, air sacs, tracheoles) bumblebees express this extreme hypermetry. Here we use transmission electron microscopy to examine the morphology of tracheoles in bumblebee flight muscle among sister bumblebees varying nearly four-fold in body mass. Neither tracheole density nor tracheole diameter changed with body mass. The total cross-sectional area of tracheoles was also invariant with body mass. Together, these results reveal that bumblebees do not compensate for size-related limitations on oxygen delivery by increasing investment at the level of the tracheoles. Copyright © 2014 Elsevier Inc. All rights reserved.

  12. Maternal obesity, gestational weight gain and childhood cardiac outcomes: role of childhood body mass index.

    PubMed

    Toemen, L; Gishti, O; van Osch-Gevers, L; Steegers, E A P; Helbing, W A; Felix, J F; Reiss, I K M; Duijts, L; Gaillard, R; Jaddoe, V W V

    2016-07-01

    Maternal obesity may affect cardiovascular outcomes in the offspring. We examined the associations of maternal prepregnancy body mass index and gestational weight gain with childhood cardiac outcomes and explored whether these associations were explained by parental characteristics, infant characteristics or childhood body mass index. In a population-based prospective cohort study among 4852 parents and their children, we obtained maternal weight before pregnancy and in early, mid- and late pregnancy. At age 6 years, we measured aortic root diameter (cm) and left ventricular dimensions. We calculated left ventricular mass (g), left ventricular mass index (g m(-2.7)), relative wall thickness ((2 × left ventricular posterior wall thickness)/left ventricular diameter), fractional shorting (%), eccentric left ventricular hypertrophy and concentric remodeling. A one standard deviation score (SDS) higher maternal prepregnancy body mass index was associated with higher left ventricular mass (0.10 SDS (95% confidence interval (CI) 0.08, 0.13)), left ventricular mass index (0.06 SDS (95% CI 0.03, 0.09)) and aortic root diameter (0.09 SDS (95% CI 0.06, 0.12)), but not with relative wall thickness or fractional shortening. A one SDS higher maternal prepregnancy body mass index was associated with an increased risk of eccentric left ventricular hypertrophy (odds ratio 1.21 (95% CI 1.03, 1.41)), but not of concentric remodeling. When analyzing the effects of maternal weight in different periods simultaneously, only maternal prepregnancy weight and early pregnancy weight were associated with left ventricular mass, left ventricular mass index and aortic root diameter (P-values<0.05), independent of weight in other pregnancy periods. All observed associations were independent of parental and infant characteristics, but attenuated to non-significance after adjustment for childhood body mass index. Maternal prepregnancy body mass index and weight gain in early pregnancy are both associated with offspring cardiac structure in childhood, but these associations seem to be fully explained by childhood body mass index.

  13. SIGNATURES OF RECENT ASTEROID DISRUPTIONS IN THE FORMATION AND EVOLUTION OF SOLAR SYSTEM DUST BANDS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kehoe, A. J. Espy; Colwell, J. E.; Kehoe, T. J. J.

    We have performed detailed dynamical modeling of the structure of a faint dust band observed in coadded InfraRed Astronomical Satellite data at an ecliptic latitude of 17° that convincingly demonstrates that it is the result of a relatively recent (significantly less than 1 Ma) disruption of an asteroid and is still in the process of forming. We show here that young dust bands retain information on the size distribution and cross-sectional area of dust released in the original asteroid disruption, before it is lost to orbital and collisional decay. We find that the Emilkowalski cluster is the source of thismore » partial band and that the dust released in the disruption would correspond to a regolith layer ∼3 m deep on the ∼10 km diameter source body's surface. The dust in this band is described by a cumulative size-distribution inverse power-law index with a lower bound of 2.1 (implying domination of cross-sectional area by small particles) for dust particles with diameters ranging from a few μm up to a few cm. The coadded observations show that the thermal emission of the dust band structure is dominated by large (mm–cm size) particles. We find that dust particle ejection velocities need to be a few times the escape velocity of the Emilkowalski cluster source body to provide a good fit to the inclination dispersion of the observations. We discuss the implications that such a significant release of material during a disruption has for the temporal evolution of the structure, composition, and magnitude of the zodiacal cloud.« less

  14. Communication: electronic band gaps of semiconducting zig-zag carbon nanotubes from many-body perturbation theory calculations.

    PubMed

    Umari, P; Petrenko, O; Taioli, S; De Souza, M M

    2012-05-14

    Electronic band gaps for optically allowed transitions are calculated for a series of semiconducting single-walled zig-zag carbon nanotubes of increasing diameter within the many-body perturbation theory GW method. The dependence of the evaluated gaps with respect to tube diameters is then compared with those found from previous experimental data for optical gaps combined with theoretical estimations of exciton binding energies. We find that our GW gaps confirm the behavior inferred from experiment. The relationship between the electronic gap and the diameter extrapolated from the GW values is also in excellent agreement with a direct measurement recently performed through scanning tunneling spectroscopy.

  15. Blow-out protector and fire control system for petroleum exploration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Caraway, M.F.; Caraway, B.L.

    1987-10-06

    A blow-out protector is described for an oil well comprising a housing having a vertical passageway therethrough for a Kelly. The housing has a lower end adapter flange to be connected to a well casing, an elastomeric body having an opening for the Kelly and carried on the Kelly for providing sealing contact with the Kelly and housing passageway, a catch ring secured to the Kelly and having a surface defined by a given diameter, a compressor ring plate positioned below the elastomeric body on the Kelly, means on an interior of the housing having a given diameter and preventingmore » the compressor ring plate from falling down and yet providing engagement with the surface of the catch ring, the compressor ring plate having a hole for passage of the Kelly drive-mechanism for the drill pipe, the catch ring on the Kelly positioned below the compressor plate. The diameter of the catch ring is smaller than the diameter of the interior means on the housing so that when the Kelly is pulled up the catch ring will contact and force the compressor ring plate against the elastomeric body and force the elastomeric body into tight contact with both the Kelly and the housing thus sealing the space between the Kelly and the housing against a blow-out.« less

  16. Change in human lens dimensions, lens refractive index distribution and ciliary body ring diameter with accommodation

    PubMed Central

    Khan, Adnan; Pope, James M.; Verkicharla, Pavan K.; Suheimat, Marwan; Atchison, David A.

    2018-01-01

    We investigated changes in ciliary body ring diameter, lens dimensions and lens refractive index distributions with accommodation in young adults. A 3T clinical magnetic resonance imaging scanner imaged right eyes of 38 18-29 year old participants using a multiple spin echo sequence to determine accommodation-induced changes along lens axial and equatorial directions. Accommodation stimuli were approximately 1 D and 5 D. With accommodation, ciliary body ring diameter, and equatorial lens diameter decreased (–0.43 ± 0.31 mm and –0.30 ± 0.23 mm, respectively), and axial lens thickness increased ( + 0.34 ± 0.16 mm). Lens shape changes cause redistribution of the lens internal structure, leading to change in refractive index distribution profiles. With accommodation, in the axial direction refractive index profiles became flatter in the center and steeper near the periphery of the lens, while in the equatorial direction they became steeper in the center and flatter in the periphery. The results suggest that the anatomical accuracy of lens optical models can be improved by accounting for changes in the refractive index profile during accommodation. PMID:29541520

  17. INAA of CAIs from the Maralinga CK4 chondrite: Effects of parent body thermal metamorphism

    NASA Technical Reports Server (NTRS)

    Lindstrom, D. J.; Keller, L. P.; Martinez, R. R.

    1993-01-01

    Maralinga is an anomalous CK4 carbonaceous chondrite which contains numerous Ca-, Al-rich inclusions (CAI's) unlike the other members of the CK group. These CAI's are characterized by abundant green hercynitic spinel intergrown with plagioclase and high-Ca clinopyroxene, and a total lack of melilite. Instrumental Neutron Activation Analysis (INAA) was used to further characterize the meteorite, with special focus on the CAI's. High sensitivity INAA was done on eight sample disks about 100-150 microns in diameter obtained from a normal 30 micron thin section with a diamond microcoring device. The CAI's are enriched by 60-70X bulk meteorite values in Zn, suggesting that the substantial exchange of Fe for Mg that made the spinel in the CAI's hercynitic also allowed efficient scavenging of Zn from the rest of the meteorite during parent body thermal metamorphism. Less mobile elements appear to have maintained their initial heterogeneity.

  18. Wind Tunnel Investigation of a Balloon as Decelerator at Mach Numbers from 1.47 to 2.50

    NASA Technical Reports Server (NTRS)

    McShera, John T.; Keyes, J. Wayne

    1961-01-01

    A wind-tunnel investigation was conducted to study the characteristics of a towed spherical balloon as a drag device at Mach numbers from 1.47 to 2.50, Reynolds numbers from 0.36 x 10(exp 6) to 1.0 x 10(exp 6) , and angles of attack from -15 to 15 degrees. Tow-cable length was approximately 24 inches from asymmetric body to cone on the upstream side of the balloon. As the tow cable was lengthened the balloon reached a point in the test section where wall-reflected shocks intersected the balloon and caused severe oscillations. As a result, the tow cable broke and the inflatable balloon model was destroyed. Further tests used a model rigid plastic sphere 6.75 inches in diameter. Tow cable length was approximately 24 inches from asymmetric body to the upstream side of the sphere.

  19. Reference values of left heart echocardiographic dimensions and mass in male peri-pubertal athletes.

    PubMed

    Cavarretta, Elena; Maffessanti, Francesco; Sperandii, Fabio; Guerra, Emanuele; Quaranta, Federico; Nigro, Antonia; Minati, Monia; Rebecchi, Marco; Fossati, Chiara; Calò, Leonardo; Pigozzi, Fabio

    2018-01-01

    Background Several articles have proposed reference values in healthy paediatric subjects, but none of them has evaluated a large population of healthy trained adolescents. Design The study purpose was to establish normal echocardiographic measurements of left heart (aortic root, left atrium and left ventricular dimensions and mass) in relation to age, weight, height, body mass index, body surface area and training hours in this specific population. Methods We retrospectively evaluated 2151 consecutive, healthy, peri-pubertal athletes (100% male, mean age 12.4 ± 1.4 years, range 8-18) referred to a single centre for pre-participation screening. All participants were young soccer athletes who trained for a mean of 7.2 ± 1.1 h per week. Results Left ventricular internal diameters, wall thickness, left ventricular mass, aortic root and left atrium diameters were significantly correlated to age, body surface area, height and weight ( p < 0.01). Age, height, weight and body surface area were found associated with chamber size, while body mass index and training hours were not. Inclusion of both age and body size parameters in the statistical models resulted in improved overall explained variance for diameters and left ventricular mass. Conclusion Equations, mean values and percentile charts for the different age groups may be useful as reference data in efficiently assessing left ventricular parameters in young athletes.

  20. Calibration Tunnel for High Speed

    NASA Technical Reports Server (NTRS)

    Pretsch, J.

    1946-01-01

    For the nvestigation of measuring instruments at higher speeds up to a Mach number 0.7 a tunnel with closed test section was built in 1942 which was as simple and cheap as possble. The blower was a radial blower with straight sheet vanes of 800-millimeter diameter the tips of which were bent backward a little. The blower sucks the air through a honeycomb of diameter 1.2 neter with wide meshes. The air is then accelerated in a short cone with smooth transition to the test section. The cylindrical test section of 200-milimeter diameter has two windows (which are displaced 180 deg from each other. The instruments may be introduced and observed through and observed through these windows. . The cross section is then enlarged by a straight diffuser 3.5 meters long and reaches the ninefold cross section. The air flows back into the room through a disk diffuser of 2-meter diameter. The maximum speed in the jet is 250 m/s for a drive power of 35 kT., if there are no installations in the jet. The velocity is determined by pressure holed along the test section.

  1. Divergent selection on 63-day body weight in the rabbit: response on growth, carcass and muscle traits

    PubMed Central

    Larzul, Catherine; Gondret, Florence; Combes, Sylvie; de Rochambeau, Hubert

    2005-01-01

    The effects of selection for growth rate on weights and qualitative carcass and muscle traits were assessed by comparing two lines selected for live body weight at 63 days of age and a cryopreserved control population raised contemporaneously with generation 5 selected rabbits. The animals were divergently selected for five generations for either a high (H line) or a low (L line) body weight, based on their BLUP breeding value. Heritability (h2) was 0.22 for 63-d body weight (N = 4754). Growth performance and quantitative carcass traits in the C group were intermediate between the H and L lines (N = 390). Perirenal fat proportion (h2 = 0.64) and dressing out percentage (h2 = 0.55) ranked in the order L < H = C (from high to low). The weight and cross-sectional area of the Semitendinosus muscle, and the mean diameter of the constitutive myofibres were reduced in the L line only (N = 140). In the Longissimus muscle (N = 180), the ultimate pH (h2 = 0.16) and the maximum shear force reached in the Warner-Braztler test (h2 = 0.57) were slightly modified by selection. PMID:15588570

  2. Morphometrical study on senile larynx.

    PubMed

    Zieliński, R

    2001-01-01

    The aim of the study was a morphometrical macroscopic evaluation of senile larynges, according to its usefulness in ORL diagnostic and operational methods. Larynx preparations were taken from cadavers of both sexes, of age 65 and over, about 24 hours after death. Clinically important laryngeal diameters were collected using common morphometrical methods. A few body features were also being gathered. Computer statistical methods were used in data assessment, including basic statistics and linear correlations between diameters and between diameters and body features. The data presented in the study may be very helpful in evaluation of diagnostic methods. It may also help in selection of right operational tool' sizes, the most appropriate operational technique choice, preoperative preparations and designing and building virtual and plastic models for physicians' training.

  3. Rigid and Flexible Pavement Aircraft Tie-Downs

    DTIC Science & Technology

    2010-05-01

    Concrete Pier, Prior to PCC Placement Neenah anchors are equipped with two ½-in-diameter cored holes to allow insertion of a section of rebar through...facilitate this process, a Hilti drill was utilized to perform the concrete drilling process. The drill bit diameter exceeded the rebar diameter by...aggregate particles not become lodged against the rebar sections inside the dowel sleeves, impeding the flow of concrete and possibly creating air voids

  4. Comparison of the arithmetic and geometric means in estimating crown diameter and crown cross-sectional area

    Treesearch

    KaDonna Randolph

    2010-01-01

    The use of the geometric and arithmetic means for estimating tree crown diameter and crown cross-sectional area were examined for trees with crown width measurements taken at the widest point of the crown and perpendicular to the widest point of the crown. The average difference between the geometric and arithmetic mean crown diameters was less than 0.2 ft in absolute...

  5. Cutting roller

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Best, G.; Weikert, N.B.

    1984-05-29

    A cutting roller for a mining machine, having a substantially conical closure member arranged to face the workings and a tubular body member which has a larger diameter at the end nearer the face working face than at the discharge end. The tubular member carries at least one cutting blade, and the closure member mounts at least one cutting blade; each blade is provided at its edge region with a plurality of bit holders for the attachment of cutter bits. The outer surface of the body member merges into the substantially conical closure member in a smooth, even curve, somore » that the outside diameter of the body member in the region of the working face is substantially greater than the diameter in the region of the discharge end of the cutting roller. The roller is provided with liquid distribution channels on each cutting blade, which channels are connected to a single liquid distribution ring channel in the region of the substantially conical closure member.« less

  6. A new thermal shape memory Ti-Ni alloy stent covered with silicone.

    PubMed

    Nakamura, T; Shimizu, Y; Ito, Y; Matsui, T; Okumura, N; Takimoto, Y; Ariyasu, T; Kiyotani, T

    1992-01-01

    An attempt was made to develop an airway stent for nonsurgical transluminal implantation using a bronchofiberscope. The stent is composed of a single wire with a diameter of 0.5 mm. The wire is made of thermal shape memory titanium nickel alloy, with a transition temperature of 25-30 degrees C. To avoid direct contact between the metal and the tissue, the wire is covered with a 300 microns thick coating of silicone. The stent is horseshoe shaped in cross-section. It is 15 mm in outer transverse diameter and 40 mm long. Ten stents were implanted in 10 dogs whose tracheal cartilages had been previously broken. The stents were first cooled in ice water to reduce their diameter and then inserted into the target site. The wire was warmed to body temperature and recovered its initial shape within 10 sec. The dogs were killed for examination between 1 week and 6 months after implantation. All the stents were located at the implantation sites and were patent. Tissue reactions, such as ulceration and granulation formation, were less severe than in those with previously implanted non-silicone covered stents. Microscopic observation showed that the wires became gradually covered with epithelium within 2 months. This transluminal technique for preserving airway patency shows promise for clinical application.

  7. Fiber diameter distributions in the chinchilla's ampullary nerves

    NASA Technical Reports Server (NTRS)

    Hoffman, Larry F.; Honrubia, Vicente

    2002-01-01

    A morphometric study of the chinchilla's ampullary nerves was conducted to produce an unbiased accounting of the diameter distribution of their constituent fibers. Diameter analyses were determined from 1 microm plastic-embedded nerve sections taken at a plane immediately proximal to the sensory epithelium. We found these nerves to be composed of 2094+/-573 fibers, having diameters that ranged from 0.5 to 8 microm. The distributions of diameters were positively skewed, where approximately 75% of the fibers were found to have diameters less than 3.5 microm. An analysis of the spatial distribution of diameters within the nerve section revealed that the lateralmost areas of the nerve contained larger fractions of fibers within the smallest diameter quintiles, and the central area harbored greater proportions of the larger diameter quintiles. However, significant fractions of all quintiles were found in all areas. These data were integrated with available data of Fernandez et al. (1998) to produce diameter estimates of calyx, dimorphic, and bouton morphology subpopulations. In view of a general relationship between diameter, innervation locus, and an afferent's physiologic characteristics, these data provide the basis for developing a perspective for the in situ distribution of afferent response dynamics.

  8. Determinants and Normal Values of Ascending Aortic Diameter by Age, Gender and Race/Ethnicity in the Multi-Ethnic Study of Atherosclerosis (MESA)

    PubMed Central

    Turkbey, Evrim B.; Jain, Aditya; Johnson, Craig; Redheuil, Alban; Arai, Andrew E.; Gomes, Antoinette S.; Carr, James; Hundley, W. Gregory; Teixido-Tura, Gisela; Eng, John; Lima, Joao A.C.; Bluemke, David A.

    2013-01-01

    PURPOSE To determine the normal size and wall thickness of the ascending thoracic aorta (AA) and its relationship with cardiovascular risk factors in a large population-based study. MATERIALS AND METHODS The mean AA luminal diameter was measured in 3573 Multi-Ethnic Study of Atherosclerosis (MESA) participants (age: 45–84 years), using gradient echo phase contrast cine MRI. Multiple linear regression models were used to evaluate the associations between risk factors and AA diameter. The median and upper normal limit (95th percentile) was defined in a “healthy” subgroup as well as AA wall thickness. RESULTS The upper limits of body surface area indexed AA luminal diameter for age categories of 45–54, 55–64, 65–74, and 75–84 years are 21, 22, 22, and 28 mm/m2 in women and 20, 21, 22, 23 mm/m2 in men, respectively. The mean AA wall thickness was 2.8 mm. Age, gender and body surface area were major determinants of AA luminal diameter (~+1 mm/10 years; ~+1.9 mm in men than women; ~+1 mm/ 0.23 m2; p<0.001). The AA diameter in hypertensive subjects was +0.9 mm larger than in normotensives (p<0.001). CONCLUSION AA diameter increases gradually with aging for both genders, among all race/ethnicities. Normal value of AA diameter is provided. PMID:23681649

  9. ELECTRON MICROSCOPY OF HELA CELLS INFECTED WITH ADENOVIRUSES

    PubMed Central

    Harford, Carl G.; Hamlin, Alice; Parker, Esther; van Ravenswaay, Theodore

    1956-01-01

    HeLa cells were infected with adenoviruses (types 1–4) and sectioned for electron microscopy after intervals of 20 to 48 hours. Clusters of virus-like particles were found within the nuclei of infected cultures but not in those of uninfected controls. The particles were often arranged in rows as if in crystalline formation. Maximal diameter of particles was approximately 65 mµ, and internal bodies were demonstrated. Lesions of infected cells included target-like structures of the nuclear membrane, large nuclear vacuoles (type 2), and increased numbers of large irregular electron-dense granules in the cytoplasm 48 hours after infection. Examination of infected cultures by light microscopy, using the Feulgen reaction, showed intranuclear inclusion bodies and a cytopathogenic effect consisting of clumping of cells without pyknosis of nuclei. A lipide stain showed numerous cytoplasmic granules that were not identical with the large, irregular, electron-dense granules of the cytoplasm. Practically all the cells showed the viral cytopathogenic effect, but only a minority of cells were found to contain virus-like particles or intranuclear inclusion bodies. PMID:13357696

  10. The validity of arterial measurements in a South African embalmed body population.

    PubMed

    Schoeman, Marelize; van Schoor, Albert; Suleman, Farhana; Louw, Liebie; du Toit, Peet

    2018-01-01

    Knowledge of the normal arterial diameter at a given anatomical point is the first step toward quantifying the severity of cardiovascular diseases. According to several studies, parameters such as weight, height, age and sex can explain morphometric variations in arterial anatomy that are observed in a population. Before the development of a reference database against which to compare the diameters of arteries in a variety of pathological conditions, the compatibility between embalmed body measurements and computed tomography (CT) measurements must first be established. The aim of this study was to compare embalmed body measurements and CT measurements at 19 different arterial sites to establish whether embalmed body measurements are a true reflection of a living population. A total of 154 embalmed bodies were randomly selected from the Department of Anatomy at the University of Pretoria and 36 embalmed bodies were randomly selected from the Department of Human Anatomy at the University of Limpopo, Medunsa Campus. Dissections were performed on the embalmed body sample and the arterial dimensions were measured with a mechanical dial-sliding caliper (accuracy of 0.01 mm). 30 CT images for each of the 19 arterial sites were retrospectively selected from the database of radiographic images at the Department of Radiology, Steve Biko Academic Hospital. Radiant, a Digital Imaging and Communications in Medicine (DICOM) viewer was used to analyze the CT images. The only statistically significant differences between the embalmed body measurements and CT measurements were found in the left common carotid- and the left subclavian arteries. The null hypothesis of no statistically significant difference between the embalmed body and CT measurements was accepted since the P value indicated no significant difference for 87% of the measurements, the exception being the left common carotid- and the left subclavian arteries. With the exception of two measurements, measurements in embalmed bodies and living people are interchangeable and concerns regarding the effect of distortion and shrinkage are unfounded. Even small changes in arterial diameter greatly influence blood flow and blood pressure, which contribute to undesirable clinical outcomes such as aortic aneurysms and aortic dissections. This study completes the first step towards the development of a reference database against which to compare the diameters of arteries in a variety of pathological conditions in a South African population.

  11. Aortic root dilation in kidney transplant recipients.

    PubMed

    Obremska, Marta; Boratyńska, Maria; Szymczak, Maciej; Zyśko, Dorota; Płonek, Tomasz; Goździk, Anna; Klinger, Marian

    2018-05-30

    INTRODUCTION Aortic root (AoR) dilation is associated with cardiac damage and higher cardiovascular risk. Cardiovascular disease is the most common cause of death in patients after kidney transplantation (KTx ). OBJECTIVES The aim of this study was to assess the prevalence of enlarged AoR diameter in KTx recipients. Patients with bicuspid aortic valve, significant valvular disease, or evidence of connective tissue disorder were excluded. PATIENTS AND METHODS A total of 87 KTx recipients were divided into 2 groups depending on immunosuppressive regimen: 41 patients receiving mammalian target of rapamycin inhibitors (mTORi) and 46 patients treated with calcineurin inhibitors (CNIs). In all patients, echocardiography was performed, laboratory and clinical markers of cardiovascular risk were assessed, and the AoR diameter was calculated. RESULTS There were no differences between groups in age, sex, body surface area, body mass index, frequency of diabetes, hypertension, dyslipidemia, time after replacement therapy, creatinine levels, and estimated glomerular filtration rate. In the CNI group, the observed and calculated AoR diameters were similar (P = 0.8). In the mTORi group, the observed AoR diameter was higher than the calculated one (P = 0.002). The concentric and eccentric left ventricular hypertrophy was similar in both groups (P = 0.12 and P = 0.69, respectively). In the stepwise regression analysis, the AoR diameter was associated with body surface area and mTORi treatment. CONCLUSIONS KTx recipients have a high prevalence of AoR dilation. Immunosuppressive regimen based on mTORi increases the incidence of AoR enlargement.

  12. Abdominal obesity, ethnicity and gastro‐oesophageal reflux symptoms

    PubMed Central

    Corley, Douglas A; Kubo, Ai; Zhao, Wei

    2007-01-01

    Objective To evaluate the associations between abdominal obesity and gastro‐oesophageal reflux disease (GORD), and their interactions with ethnicity and gender. Design A cross‐sectional study. Participants completed detailed symptom questionnaires and underwent a standardised examination, including anthropometric measurements. Setting A large integrated healthcare system. Patients 80 110 members of the Kaiser Permanente multiphasic health check‐up cohort. Main outcome measures Gastro‐oesophageal reflux‐type symptoms. Results Recent reflux‐type symptoms were present in 11% of the population. The multivariate OR for symptoms with an abdominal diameter (adjusted for body mass index (BMI)) of ⩾26 vs <16.3 cm was 1.85 (95% CI 1.55 to 2.21) for the white population, 0.95 (95% CI 0.61 to 1.48) for the black population and 0.64 (95% CI 0.18 to 2.30) for Asians. The mean abdominal diameter was greater in men (22.0 cm, 95% CI 21.9 to 22.0) than in women (20.1 cm, 95% CI 20.0 to 20.1, p<0.01), but the risk of symptoms for any given diameter did not differ markedly by gender. The association between increasing BMI and symptoms was also much stronger among the white population than among the black population. The association between BMI and reflux‐type symptoms was partially mediated through abdominal diameter. Conclusions There was a consistent association between abdominal diameter (independent of BMI) and reflux‐type symptoms in the white population, but no consistent associations in the black population or Asians. The BMI association was also strongest among the white population. These findings, combined with the increased prevalence of abdominal obesity in male subjects, suggest that an increased obesity may disproportionately increase GORD‐type symptoms in the white population and in male subjects. PMID:17047097

  13. Comparison of the Experimental and Theoretical Distribution of Lift on a Slender Inclined Body of Revolution at M = 2

    NASA Technical Reports Server (NTRS)

    Perkins, Edward W; Kuehn, Donald M

    1953-01-01

    Pressure distributions and force characteristics have been determined for a body of revolution consisting of a fineness ratio 5.75, circular-arc, ogival nose tangent to a cylindrical afterbody for an angle-of-attack range of 0 degrees to 35.5 degrees. The free-stream Mach number was 1.98 and the free-stream Reynolds number was approximately 0.5 x 10 sup 6, based on body diameter. Comparison of the theoretical and experimental pressure distributions shows that for zero lift, either slender-body theory or higher-order theories yield results which are in good agreement with experiment. For the lifting case, good agreement with theory is found only for low angles of attack and for the region in which the body cross-sectional area is increasing in the downstream direction. Because of the effects of cross-flow separation and the effects of compressibility due to the high cross-flow Mach numbers at large angles of attack, the experimental pressure distributions differ from those predicted by potential theory. Although the flow about the inclined body was, in general, similar to that assumed as the basis for Allen's method of estimating the forces resulting from viscous effects (NACA RM A91I26), the distribution of the forces was significantly different from that assumed. Nevertheless, the lift and pitching-moment characteristics were in fair agreement with the estimated value.

  14. The prevalence of cervical myelopathy among subjects with narrow cervical spinal canal in a population-based magnetic resonance imaging study: the Wakayama Spine Study.

    PubMed

    Nagata, Keiji; Yoshimura, Noriko; Hashizume, Hiroshi; Muraki, Shigeyuki; Ishimoto, Yuyu; Yamada, Hiroshi; Takiguchi, Noboru; Nakagawa, Yukihiro; Minamide, Akihito; Oka, Hiroyuki; Kawaguchi, Hiroshi; Nakamura, Kozo; Akune, Toru; Yoshida, Munehito

    2014-12-01

    A narrow cervical spinal canal (CSC) is a well-known risk factor for cervical myelopathy (CM). However, no epidemiologic data of the CSC based on a population-based cohort are available. The purpose of the study was to investigate the age-related differences in CSC diameters on plain radiographs and to examine the associated magnetic resonance imaging (MRI) abnormalities including cervical cord compression and increased signal intensity (ISI) as well as the clinical CM with the narrow CSC. This was a cross-sectional study. Data were obtained from the baseline survey of the Wakayama Spine Study that was performed from 2008 to 2010 in a western part of Japan. Finally, a total of 959 subjects (319 men and 640 women; mean age, 66.4 years) were included. The outcome measures included in the study were the CSC diameter at C5 level on plain radiographs, cervical cord compression and ISI on sagittal T2-weighted MRI, and physical signs related to CM (eg, the Hoffmann reflex, hyperreflexia of the patellar tendon, the Babinski reflex, sensory and motor function, and bowel/bladder symptoms). The age-related differences of CSC diameters in men and women were investigated by descriptive statistics. The prevalence of MRI abnormalities and clinical CM was compared among the groups divided by the CSC diameter (less than 13, 13-15, and 15 mm or more). In addition, a logistic regression analysis was performed to determine the association of the CSC diameter with cervical cord compression/clinical CM after overall adjustment for age, sex, and body mass index. The CSC diameter was narrower with increasing age in both men and women. The prevalence of cervical cord compression, ISI, and the clinical CM was significantly higher in the narrower CSC group. The prevalence of cervical cord compression, ISI, and CM among subjects with CSC diameter less than 13 mm was 38.0%, 5.4%, and 10.1%, respectively. In the logistic model, the CSC diameter was a significant predictive factor for the clinical CM (p<.0001). This study firstly confirmed the age-related differences in CSC diameters and the significant association of the narrow CSC diameter with CM in a population-based cohort. Copyright © 2014 Elsevier Inc. All rights reserved.

  15. The Body Composition of a College Football Team.

    ERIC Educational Resources Information Center

    Wickkiser, John D.; Kelly, John M.

    This study focuses on the body composition and anthropometric measurements of 65 college football players. Body composition was determined by underwater weighing with an accurate assessment of residual volume. The anthropometric measurements included height, weight, seven skinfolds, waist circumference, and wrist diameter. A step-wise multiple…

  16. Fluid-structure interaction of a rolling restrained body of revolution at high angles of attack

    NASA Astrophysics Data System (ADS)

    Degani, D.; Ishay, M.; Gottlieb, O.

    2017-03-01

    The current work investigates numerically rolling instabilities of a free-to-roll slender rigid-body of revolution placed in a wind tunnel at a high angle of attack. The resistance to the roll moment is represented by a linear torsion spring and equivalent linear damping representing friction in the bearings of a simulated wind tunnel model. The body is subjected to a three-dimensional, compressible, laminar flow. The full Navier-Stokes equations are solved using the second-order implicit finite difference Beam-Warming scheme, adapted to a curvilinear coordinate system, whereas the coupled structural second order equation of motion for roll is solved by a fourth-order Runge-Kutta method. The body consists of a 3.5-diameter tangent ogive forebody with a 7.0-diameter long cylindrical afterbody extending aft of the nose-body junction to x/D = 10.5. We describe in detail the investigation of three angles of attack 20°, 40°, and 65°, at a Reynolds number of 30 000 (based on body diameter) and a Mach number of 0.2. Three distinct configurations are investigated as follows: a fixed body, a free-to-roll body with a weak torsion spring, and a free-to-roll body with a strong torsion spring. For each angle of attack the free-to-roll configuration portrays a distinct and different behavior pattern, including bi-stable limit-cycle oscillations. The bifurcation structure incorporates both large and small amplitude periodic roll oscillations where the latter lose their periodicity with increasing stiffness of the restraining spring culminating with distinct quasiperiodic oscillations. We note that removal of an applied upstream disturbance for a restrained body does not change the magnitude or complexity of the oscillations or of the flow patterns along the body. Depending on structure characteristics and flow conditions even a small rolling moment coefficient at the relatively low angle of attack of 20° may lead to large amplitude resonant roll oscillations.

  17. Retransformation bias in a stem profile model

    Treesearch

    Raymond L. Czaplewski; David Bruce

    1990-01-01

    An unbiased profile model, fit to diameter divided by diameter at breast height, overestimated volume of 5.3-m log sections by 0.5 to 3.5%. Another unbiased profile model, fit to squared diameter divided by squared diameter at breast height, underestimated bole diameters by 0.2 to 2.1%. These biases are caused by retransformation of the predicted dependent variable;...

  18. Rapid-quench axially staged combustor

    DOEpatents

    Feitelberg, Alan S.; Schmidt, Mark Christopher; Goebel, Steven George

    1999-01-01

    A combustor cooperating with a compressor in driving a gas turbine includes a cylindrical outer combustor casing. A combustion liner, having an upstream rich section, a quench section and a downstream lean section, is disposed within the outer combustor casing defining a combustion chamber having at least a core quench region and an outer quench region. A first plurality of quench holes are disposed within the liner at the quench section having a first diameter to provide cooling jet penetration to the core region of the quench section of the combustion chamber. A second plurality of quench holes are disposed within the liner at the quench section having a second diameter to provide cooling jet penetration to the outer region of the quench section of the combustion chamber. In an alternative embodiment, the combustion chamber quench section further includes at least one middle region and at least a third plurality of quench holes disposed within the liner at the quench section having a third diameter to provide cooling jet penetration to at least one middle region of the quench section of the combustion chamber.

  19. Effects of Centrifuge Diameter and Operation on Rodent Adaptation to Chronic Centrifugation

    NASA Technical Reports Server (NTRS)

    Fuller, Charles A.

    1997-01-01

    This study examined the responses of rats to centrifugation in a constant acceleration field (1.5 G). Centrifuge diameter (1.8m, 2.5m or 6.0m) and schedule of operation (Daily or weekly stop) varied between groups. Body mass, food consumption, water consumption and neurovestibular function were measured weekly. Body temperature and activity were continuously monitored using telemetry. A subset of subjects were videotaped (50 minutes per day) to allow for movement analysis. Exposure to a hyperdynamic field of this magnitude did cause the expected depression in the physiological variables monitored. Recovery was accomplished within a relatively rapid time frame; all variables returned to precentrifugation levels. In general, the magnitudes of the changes and the rate of recovery were similar at different centrifuge diameters and stopping frequency. There were cases, however, in which the magnitude of the response and/or the rate of recovery to a new steady-state were altered as a result of centrifuge diameter. In summary, these results indicate that stopping frequency has little, if any, effect on adaptation to chronic centrifugation. However, the angular velocity (omega), and therefore centrifuge diameter is an important consideration in the adaptation of an organism to chronic centrifugation.

  20. Effects of Centrifuge Diameter and Operation on Rodent Adaptation to Chronic Centrifugation

    NASA Technical Reports Server (NTRS)

    Fuller, Charles A.

    1992-01-01

    This study examined the responses of rats to centrifugation in a constant acceleration field (1.5 G). Centrifuge diameter (1.8m, 2.5m or 6.0m) and schedule of operation (Daily or weekly stop) varied between groups. Body mass, food consumption, water consumption and neurovestibular function were measured weekly. Body temperature and activity were continuously monitored using telemetry. A subset of subjects were videotaped (50 minutes per day) to allow for movement analysis. Exposure to a hyperdynamic field of this magnitude did cause the expected depression in the physiological variables monitored. Recovery was accomplished within a relatively rapid time frame; all variables returned to precentrifugation levels. In general, the magnitudes of the changes and the rate of recovery were similar at different centrifuge diameters and stopping frequency. There were cases, however, in which the magnitude of the response and/or the rate of recovery to a new steady-state were altered as a result of centrifuge diameter. In summary, these results indicate that stopping frequency has little, if any, effect on adaptation to chronic centrifugation. However, the angular velocity (omega), and therefore centrifuge diameter is an important consideration in the adaptation of an organism to chronic centrifugation.

  1. Morphing hull implementation for unmanned underwater vehicles

    NASA Astrophysics Data System (ADS)

    Miller, Timothy F.; Gandhi, Farhan; Rufino, Russell J.

    2013-11-01

    There has been much interest and work in the area of morphing aircraft since the 1980s. Morphing could also potentially benefit unmanned underwater vehicles (UUVs). The current paper envisions a UUV with an interior pressure hull and a variable diameter outer flexible hull with fuel stored in the annulus between, and presents a mechanism to realize diameter change of the outer hull. The outer hull diameter of UUVs designed for very long endurance/range could be progressively reduced as fuel was consumed, thereby reducing drag and further increasing endurance and range capability. Diameter morphing could also be advantageous for compact storage of UUVs. A prototype is fabricated to represent an axial section of such a morphing diameter UUV. Diameter change is achieved using eight morphing trusses arranged equidistant around the circumference of the representative interior rigid hull. Each morphing truss has a lower rail (attached to the rigid hull) and an upper rail with V-linkages between, at either ends of the rail. Horizontal motion of the feet of the V-linkages (sliding in the lower rail) results in vertical motion of the upper rail which in turn produces diameter change of the outer hull. For the prototype built and tested, a 63% increase in outer diameter from 12.75″ to 20.75″ was achieved. The introduction of a stretched latex representative flexible skin around the outer rails increased actuation force requirement and led to a propensity for the wheel-in-track sliders in the morphing truss to bind. It is anticipated that this could be overcome with higher precision manufacturing. In addition to symmetric actuation of the morphing trusses resulting in diameter change, the paper also shows that with asymmetric actuation the hull cross-section shape can be changed (for example, from a circular section for underwater operation to a V-section for surface operations).

  2. The use of non‐adult vertebral dimensions as indicators of growth disruption and non‐specific health stress in skeletal populations

    PubMed Central

    Gowland, Rebecca L.

    2015-01-01

    ABSTRACT Objective Traditional methods of detecting growth disruption have focused on deficiencies in the diaphyseal length of the long bones. This study proposes the implementation of vertebral measurements (body height and transverse diameter of the neural canal) from non‐adults (0–17 years) as a new methodology for the identification of growth disruption. Methods Measurements of vertebral body height and transverse diameter were taken from 96 non‐adult skeletons and 40 adult skeletons from two post‐medieval sites in England (Bow Baptist, London and Coronation Street, South Shields). Non‐adult measurements were plotted against dental age to construct vertebral growth profiles through which inter‐population comparisons could be made. Results Results demonstrated that both sites experienced some growth retardation in infancy, evident as deficiencies in transverse diameter. However, analysis of vertebral body height revealed different chronologies of growth disruption between the sites, with a later age of attainment of skeletal maturity recorded in the Bow Baptist sample. Discussion These vertebral dimensions undergo cessation of growth at different ages, with transverse diameter being “locked‐in” by ∼1–2 years of age, while vertebral body height may continue to grow into early adulthood. These measurements can therefore provide complementary information regarding the timing of growth disruption within archaeological populations. Non‐adult vertebral measurements can increase our osteobiographical understanding of the timings of episodes of health stress, and allow for the analysis of growth when other skeletal elements are fragmentary. Am J Phys Anthropol 158:155–164, 2015. © 2015 Wiley Periodicals, Inc. PMID:26118898

  3. Effect of Convection Associated with Cross-section Change during Directional Solidification of Binary Alloys on Dendritic Array Morphology and Macrosegregation

    NASA Astrophysics Data System (ADS)

    Ghods, Masoud

    This dissertation explores the role of different types of convection on macrosegregation and on dendritic array morphology of two aluminum alloys directionally solidified through cylindrical graphite molds having both cross-section decrease and increase. Al- 19 wt. % Cu and Al-7 wt. % Si alloys were directionally solidified at two growth speed of 10 and 29.1 mum s-1 and examined for longitudinal and radial macrosegregation, and for primary dendrite spacing and dendrite trunk diameter. Directional solidification of these alloys through constant cross-section showed clustering of primary dendrites and parabolic-shaped radial macrosegregation profile, indicative of "steepling convection" in the mushy-zone. The degree of radial macrosegregation increased with decreased growth speed. The Al- 19 wt. % Cu samples, grown under similar conditions as Al-7 wt. % Si, showed more radial macrosegregation because of more intense "stepling convection" caused by their one order of magnitude larger coefficient of solutal expansion. Positive macrosegregation right before, followed by negative macrosegregation right after an abrupt cross-section decrease (from 9.5 mm diameter to 3.2 mm diameter), were observed in both alloys; this is because of the combined effect of thermosolutal convection and area-change-driven shrinkage flow in the contraction region. The degree of macrosegregation was found to be higher in the Al- 19 wt. % Cu samples. Strong area-change-driven shrinkage flow changes the parabolic-shape radial macrosegregation in the larger diameter section before contraction to "S-shaped" profile. But in the smaller diameter section after the contraction very low degree of radial macrosegregation was found. The samples solidified through an abrupt cross-section increase (from 3.2 mm diameter to 9.5 mm diameter) showed negative macrosegregation right after the cross-section increase on the expansion platform. During the transition to steady-state after the expansion, radial macrosegregation profile in locations close to the expansion was found to be "S-shaped". This is attributed to the redistribution of solute-rich liquid ahead of the mushy-zone as it transitions from the narrow portion below into the large diameter portion above. Solutal remelting and fragmentation of dendrite branches, and floating of these fragmented pieces appear to be responsible for spurious grains formation in Al- 19 wt. % Cu samples after the cross-section expansion. New grain formation was not observed in Al-7 wt. % Si in similar locations; it is believed that this is due to the sinking of the fragmented dendrite branches in this alloy. Experimentally observed radial and axial macrosegregations agree well with the results obtained from the numerical simulations carried out by Dr. Mark Lauer and Prof. David R. Poirier at the University of Arizona. Trunk Diameter (TD) of dendritic array appears to respond more readily to the changing growth conditions as compared to the Nearest Neighbor Spacing (NNS) of primary dendrites.

  4. 49 CFR 238.429 - Safety appliances.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ...-inch diameter steel pipe, 5/8-inch thickness steel, or a material of equal or greater mechanical strength. (2) All safety appliances shall be securely fastened to the car body structure with mechanical fasteners that have mechanical strength greater than or equal to that of a 1/2-inch diameter SAE grade steel...

  5. 49 CFR 238.429 - Safety appliances.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ...-inch diameter steel pipe, 5/8-inch thickness steel, or a material of equal or greater mechanical strength. (2) All safety appliances shall be securely fastened to the car body structure with mechanical fasteners that have mechanical strength greater than or equal to that of a 1/2-inch diameter SAE grade steel...

  6. Subsonic Dynamics of Stardust Sample Return Capsule

    NASA Technical Reports Server (NTRS)

    Mitcheltree, Robert A.; Fremaux, Charles M.

    1997-01-01

    Subsonic dynamic stability tests performed in the NASA Langley 20-Foot Vertical Spin-Tunnel on a 0.238 scale model of the Stardust Sample Return Capsule are discussed. The tests reveal that the blunted 60 degree half-angle cone capsule is dynamically unstable at low subsonic conditions due to the aft location of the center-of-gravity (0.351 body diameters back from the nose). The divergent behavior of the capsule continued when the center-of-gravity was moved to 0.337 and 0.313 body diameters back from the nose. When the center-of-gravity was moved further forward to 0.290 body diameters back from the nose, the vehicle established itself in a limit cycle with amplitude around 10 degrees. Two afterbody modifications were examined which proved unsuccessful in alleviating the instability of the original design. Finally, the addition of different sized parachutes was examined as a means to stabilize the vehicle. The parachute tests indicate that a parachute with equivalent full scale drag area of at least 2.24 ft. is necessary to assure large perturbations are damped.

  7. A reduced estimate of the number of kilometre-sized near-Earth asteroids.

    PubMed

    Rabinowitz, D; Helin, E; Lawrence, K; Pravdo, S

    2000-01-13

    Near-Earth asteroids are small (diameters < 10 km), rocky bodies with orbits that approach that of the Earth (they come within 1.3 AU of the Sun). Most have a chance of approximately 0.5% of colliding with the Earth in the next million years. The total number of such bodies with diameters > 1 km has been estimated to be in the range 1,000-2,000, which translates to an approximately 1% chance of a catastrophic collision with the Earth in the next millennium. These numbers are, however, poorly constrained because of the limitations of previous searches using photographic plates. (One kilometre is below the size of a body whose impact on the Earth would produce global effects.) Here we report an analysis of our survey for near-Earth asteroids that uses improved detection technologies. We find that the total number of asteroids with diameters > 1 km is about half the earlier estimates. At the current rate of discovery of near-Earth asteroids, 90% will probably have been detected within the next 20 years.

  8. A free flight investigation of transonic sting interference

    NASA Technical Reports Server (NTRS)

    Jaffe, P.

    1975-01-01

    Transonic sting interference has been studied in a supersonic wind tunnel to obtain free flight and sting support data on identical models. The two principal configurations, representing fuselage bodies, were cigar shaped with tail fins. The others were a sharp 10-deg cone, a sphere, and a blunt entry body. Comparative data indicated that the sting had an appreciable effect on drag for the fuselage-like configurations; drag rise occurred 0.02 Mach number earlier in free flight, and drag level was 15% greater. The spheres and the blunt bodies were insensitive to the presence of stings regardless of their size. The 10-deg cones were in between, experiencing no drag difference with a minimum diameter sting, but a moderate difference with the largest diameter sting tested. All data tend to confirm the notion that for the more slender bodies the sting not only affects flow but the forebody flow as well.

  9. Ultrastructural observations of previtellogenic ovarian follicles of dove.

    PubMed

    Zarnescu, Otilia

    2004-11-01

    Dove ovarian follicle is a complex structure composed of oocyte surrounded by a somatic compartment consisting of theca externa, theca interna and granulosa. The structure of ovarian follicle (1 and 2 mm) of dove was studied by electron microscopy. The granulosa was pseudostratified in the 1-mm-diameter follicles and stratified with two or three irregular rows of cells in the 2-mm-diameter follicles. In the larger follicle indentations between oocyte and granulosa cells become more numerous and the microvilli of granulosa cell elongated to form a zona radiata with similarly elongated oocyte microvilli. Lining bodies were present at the tips of granulosa microvilli and in the cortical region of the oocyte. In the oocyte cortex were observed coated pits, coated vesicles, dense tubules, multivesicular bodies and primordial yolk spheres. Primordial yolk spheres may contain lining bodies and were observed fused with dense tubules and multivesicular bodies or associated with smooth cisternae.

  10. Development and growth of fruit bodies and crops of the button mushroom, Agaricus bisporus.

    PubMed

    Straatsma, Gerben; Sonnenberg, Anton S M; van Griensven, Leo J L D

    2013-10-01

    We studied the appearance of fruit body primordia, the growth of individual fruit bodies and the development of the consecutive flushes of the crop. Relative growth, measured as cap expansion, was not constant. It started extremely rapidly, and slowed down to an exponential rate with diameter doubling of 1.7 d until fruit bodies showed maturation by veil breaking. Initially many outgrowing primordia were arrested, indicating nutritional competition. After reaching 10 mm diameter, no growth arrest occurred; all growing individuals, whether relatively large or small, showed an exponential increase of both cap diameter and biomass, until veil breaking. Biomass doubled in 0.8 d. Exponential growth indicates the absence of competition. Apparently there exist differential nutritional requirements for early growth and for later, continuing growth. Flushing was studied applying different picking sizes. An ordinary flushing pattern occurred at an immature picking size of 8 mm diameter (picking mushrooms once a day with a diameter above 8 mm). The smallest picking size yielded the highest number of mushrooms picked, confirming the competition and arrested growth of outgrowing primordia: competition seems less if outgrowing primordia are removed early. The flush duration (i.e. between the first and last picking moments) was not affected by picking size. At small picking size, the subsequent flushes were not fully separated in time but overlapped. Within 2 d after picking the first individuals of the first flush, primordia for the second flush started outgrowth. Our work supports the view that the acquisition of nutrients by the mycelium is demand rather than supply driven. For formation and early outgrowth of primordia, indications were found for an alternation of local and global control, at least in the casing layer. All these data combined, we postulate that flushing is the consequence of the depletion of some unknown specific nutrition required by outgrowing primordia. Copyright © 2013 The British Mycological Society. Published by Elsevier Ltd. All rights reserved.

  11. Hypersonic Wind-Tunnel Measurements of Boundary-Layer Pressure Fluctuations

    DTIC Science & Technology

    2009-08-01

    experiments. The third and fourth sections of the cone are designed to hold the instrumentation. The model can be run as a 0.102-m base-diameter cone...using the third section only, or 28 Figure 3.10. Glow-perturber section the fourth section can be added to increase the cone base diameter to 0.127 m...the second sensor. The third sensor shows an increase in frequency components above 15 kHz as well as a rise in lower frequencies. As transition

  12. Evacuated displacement compression molding

    NASA Technical Reports Server (NTRS)

    Heier, W. C. (Inventor)

    1973-01-01

    A process for molding long, thin-wall tubular bodies from thermosetting plastic molding compounds is described. The tubular bodies produced may have body lengths several times the diameters. The application of the process for manufacturing rocket engine cases and nozzles is discussed. The advantages of the system over other methods of circular tube manufacture are analyzed.

  13. Golgi, electron-microscopic and combined Golgi-electron-microscopic studies of the mitral cells in the goldfish olfactory bulb.

    PubMed

    Oka, Y

    1983-04-01

    The local neuronal circuitry of goldfish olfactory bulb was analyzed in Golgi preparations combining light- and electron-microscopy, as well as in routinely prepared ultrastructural preparations. Mitral cells were identified with the light-microscope in Golgi-impregnated thick sections according to the following criteria: (1) cell bodies were distributed irregularly in a wide layer between 100 and 200 micrometer from the surface, (2) cell bodies were larger than other neurons (10-20 micrometer in diameter), and (3) the dendrites were directed toward the superficially-located olfactory nerve layer where they ended as highly branched glomerular tufts. These impregnated cells were examined by electron-microscopy in serial section. The results demonstrate synaptic organization in relation to the mitral cells. (1) Glomerular tufts received afferent input from primary olfactory axons which made Gray's Type I synaptic contacts. These dendrites also had reciprocal dendrodendritic synapses with dendrites of certain non-mitral cells. (2) Dendritic shafts of mitral cells made reciprocal dendritic synapses with dendrites of certain non-mitral cells. (3) Cell bodies and their initial axon segments had reciprocal synapses with certain dendrites but occurred infrequently. In reciprocal synapses, the direction of the Gray Type I (asymmetrical) is away from the mitral cell while those with Gray Type II synapses (symmetrical) are toward the mitral cell. Assuming that the type I synapse is excitatory and Type II is inhibitory, these findings explain the electrophysiological demonstration of self-inhibition discharge found in mitral cells.

  14. Flowfield predictions for multiple body launch vehicles

    NASA Technical Reports Server (NTRS)

    Deese, Jerry E.; Pavish, D. L.; Johnson, Jerry G.; Agarwal, Ramesh K.; Soni, Bharat K.

    1992-01-01

    A method is developed for simulating inviscid and viscous flow around multicomponent launch vehicles. Grids are generated by the GENIE general-purpose grid-generation code, and the flow solver is a finite-volume Runge-Kutta time-stepping method. Turbulence effects are simulated using Baldwin and Lomax (1978) turbulence model. Calculations are presented for three multibody launch vehicle configurations: one with two small-diameter solid motors, one with nine small-diameter solid motors, and one with three large-diameter solid motors.

  15. Subcutaneous body lipids affect cyclicity and estrus behavior in primiparous Charolais cows.

    PubMed

    Recoules, E; De La Torre, A; Agabriel, J; Egal, D; Blanc, F

    2013-08-01

    Conception rate and the calving interval of beef cows are known to be influenced by body reserves at calving and subsequent postpartum changes. However, few studies have focused on the effect of body reserve dynamics on both postpartum cyclicity and estrus expression. Two successive similar experiments (Year 1: n=14; Year 2: n=16) were carried out on primiparous Charolais cows reared indoors during winter to quantify the effects of adipose cell diameter at calving (ACDca) and their postpartum changes (ACDch) on cyclicity and estrus behavior. Cows were managed to calve with a body condition score (BCS, scale 0-5) of 2.5 (Year 1) and 1.5 (Year 2). After calving cows were assigned to a Low vs. a High energy level diet until turn out to pasture in May. Within years ACDca was similar between Low and High groups whereas calving to turnout changes of body weight (BW), BCS and adipose cell diameter differed (P<0.0001). The interval between calving and resumption of luteal activity was negatively correlated with ACDca (P=0.001). Estrus duration (interval between first and last standing to be mounted (STBM)) was longer in Low than in High groups (P=0.02). Number of STMB was higher in Low than in High cows. Adipose cell diameter at calving and postpartum changes had distinct effects on the components of reproductive performance; emphasizing the need to consider both amounts and changes of body lipids to predict relationships between nutrition and reproduction in cows. Copyright © 2013 Elsevier B.V. All rights reserved.

  16. Experimental investigation for cavity dimensions of highly porous small bodies

    NASA Astrophysics Data System (ADS)

    Okamoto, T.; Nakamura, A.; Hasegawa, S.

    2014-07-01

    Small bodies were probably very porous during the formation of the solar system. In order to understand the surface evolution of highly porous bodies, it is necessary to investigate the impact process for targets with such high porosity. In this study, impact experiments with sintered glass-bead targets of 87 and 94 % porosities were conducted. Growth of cavities with time and the final cavity dimensions were analyzed and compared with previous studies of porous targets. Impact experiments were conducted using a two-stage light-gas gun at ISAS, Japan. The projectiles of a few millimeters were composed of titanium, aluminum, nylon, and basalt. The impact velocities ranged from 1.8 to 7.2 km s^{-1}. In order to observe the inside of the targets, we used a flash X-ray system and a micro-X-ray tomography instrument. The track shape was found to be divided into two types, elongated 'carrot' shape and short 'bulb' shape [1]. The figures on the left and right present a transmission image of the bulb shape track and a sketch of a cross section of the cavity, respectively. The results of the final maximum diameter, D_max and the final entrance-hole diameter, D_ent show that both dimensions tend to increase with impact velocity and decrease with target porosity. We adopted the scaling law of crater diameter [2] for our analysis of D_max and D_ent. The following empirical relations are obtained for targets with porosity ≥ 87 %: {D_max}/{d_p}(ρ_t/ρ_p)^{0.4} =10^{-1.52±0.27} ({Y}/ρ_t{v_0^2})^{-0.49 ± 0.07}, {D_ent}/{d_p}(ρ_t/ρ_p)^{0.4} =10^{-2.12±0.39} ({Y}/ρ_t{v_0^2})^{-0.53 ± 0.11}, where d_p, ρ_t, ρ_p, Y, and v_0 are the projectile diameter, target density, projectile density, target compressive strength, and the impact velocity, respectively. The results of the depth from the entrance hole to the maximum diameter of the cavity, L_max, shows that L_max decreases with impact velocity and increases with target porosity. If we assume that a projectile decelerates by inertial drag [1], the characteristic length L_0, which is the depth from the surface where the kinetic energy of the projectile becomes 1/e of the initial energy, is described as follows: L_0={2ρ_p}/{3C_dρ_t}d_p, where C_d is the drag coefficient that increases with dynamic pressure normalized by tensile strength of the projectile [1]. We found that L_max/d_p increases with L_0/d_p. It indicates that L_max depends on the degree of projectile deformation or disruption through the drag coefficient and also depends on the projectile-target density ratio. We will also discuss the growth of the cavity volume, maximum diameter, and depth of the cavity with time using dimensionless parameters of crater scaling [3].

  17. Paramphistomum cervi: surface topography of the tegument of adult fluke.

    PubMed

    Panyarachun, Busaba; Sobhon, Prasert; Tinikul, Yotsawan; Chotwiwatthanakun, Charoonroj; Anupunpisit, Vipavee; Anuracpreeda, Panat

    2010-06-01

    Adult Paramphistomum cervi or rumen fluke are pear-shaped, slightly concave ventrally and convex dorsally. The worm measures about 5-13 mm in length and 2-5 mm in width across the mid-section. As observed by scanning electron microscopy (SEM), the tegumental surface in all part of the body, appears highly corrugated with transverse folds alternating with grooves and is spineless. At high magnification, the surface of the fold is composed of microfolds or ridges separated by microgrooves or pits. Corrugations and invaginations of the ventral surface are also more extensive than on the dorsal surface of the body. Both anterior and posterior suckers have thick rims covered with transverse folds without spine. The genital pore is situated at the anterior third of the body. There are two types of sensory papillae on the surface: type 1 is bulbous in shape, measuring 10-15 microm in diameter at the base with nipple-like tips, and type 2 has a similar shape and size and also a short cilia on top. These sensory papillae usually occur in large clusters, each having between 5 and 20 units depending on the region of the body. Clusters of papillae on the ventral surface and around the anterior suckers tend to be more numerous and larger in size. The dorsal surface of the body has the least number of papillae. Copyright (c) 2009 Elsevier Inc. All rights reserved.

  18. On turbulent friction in straight ducts with complex cross-section: the wall law and the hydraulic diameter

    NASA Astrophysics Data System (ADS)

    Pirozzoli, Sergio

    2018-07-01

    We develop predictive formulas for friction resistance in ducts with complex cross-sectional shape based on the use of the log law and neglect of wall shear stress nonuniformities. The traditional hydraulic diameter naturally emerges from the analysis as the controlling length scale for common duct shapes as triangles and regular polygons. The analysis also suggests that a new effective diameter should be used in more general cases, yielding corrections of a few percent to friction estimates based on the traditional hydraulic diameter. Fair but consistent predictive improvement is shown for duct geometries of practical relevance, including rectangular and annular ducts, and circular rod bundles.

  19. Ultra-large supramolecular coordination cages composed of endohedral Archimedean and Platonic bodies

    NASA Astrophysics Data System (ADS)

    Byrne, Kevin; Zubair, Muhammad; Zhu, Nianyong; Zhou, Xiao-Ping; Fox, Daniel S.; Zhang, Hongzhou; Twamley, Brendan; Lennox, Matthew J.; Düren, Tina; Schmitt, Wolfgang

    2017-05-01

    Pioneered by Lehn, Cram, Peterson and Breslow, supramolecular chemistry concepts have evolved providing fundamental knowledge of the relationships between the structures and reactivities of organized molecules. A particular fascinating class of metallo-supramolecular molecules are hollow coordination cages that provide cavities of molecular dimensions promoting applications in diverse areas including catalysis, enzyme mimetics and material science. Here we report the synthesis of coordination cages with exceptional cross-sectional diameters that are composed of multiple sub-cages providing numerous distinctive binding sites through labile coordination solvent molecules. The building principles, involving Archimedean and Platonic bodies, renders these supramolecular keplerates as a class of cages whose composition and topological aspects compare to characteristics of edge-transitive {Cu2} MOFs with A3X4 stoichiometry. The nature of the cavities in these double-shell metal-organic polyhedra and their inner/outer binding sites provide perspectives for post-synthetic functionalizations, separations and catalysis. Transmission electron microscopy studies demonstrate that single molecules are experimentally accessible.

  20. Ultra-large supramolecular coordination cages composed of endohedral Archimedean and Platonic bodies

    PubMed Central

    Byrne, Kevin; Zubair, Muhammad; Zhu, Nianyong; Zhou, Xiao-Ping; Fox, Daniel S.; Zhang, Hongzhou; Twamley, Brendan; Lennox, Matthew J.; Düren, Tina; Schmitt, Wolfgang

    2017-01-01

    Pioneered by Lehn, Cram, Peterson and Breslow, supramolecular chemistry concepts have evolved providing fundamental knowledge of the relationships between the structures and reactivities of organized molecules. A particular fascinating class of metallo-supramolecular molecules are hollow coordination cages that provide cavities of molecular dimensions promoting applications in diverse areas including catalysis, enzyme mimetics and material science. Here we report the synthesis of coordination cages with exceptional cross-sectional diameters that are composed of multiple sub-cages providing numerous distinctive binding sites through labile coordination solvent molecules. The building principles, involving Archimedean and Platonic bodies, renders these supramolecular keplerates as a class of cages whose composition and topological aspects compare to characteristics of edge-transitive {Cu2} MOFs with A3X4 stoichiometry. The nature of the cavities in these double-shell metal-organic polyhedra and their inner/outer binding sites provide perspectives for post-synthetic functionalizations, separations and catalysis. Transmission electron microscopy studies demonstrate that single molecules are experimentally accessible. PMID:28485392

  1. Shrinking plastic tubing and nonstandard diameters

    NASA Technical Reports Server (NTRS)

    Ruiz, W. V.; Thatcher, C. S.

    1980-01-01

    Process allows larger-than-normal postshrink diameters without splitting. Tetrafluoroethylene tubing on mandrel is supported within hot steel pipe by several small diameter coil sections. Rising temperature of mandrel is measured via thermocouple so assembly can be removed without overshrinking (and splitting) of tubing.

  2. The temperature of unheated bodies in a high-speed gas stream

    NASA Technical Reports Server (NTRS)

    Eckert, E; Weise, W

    1941-01-01

    The present report deals with temperature measurements on cylinders of 0.2 to 3 millimeters diameter in longitudinal and transverse air flow at speeds of 100 to 300 meters per second. Within the explored test range, that is, the probable laminar boundary layer region, the temperature of the cylinders in axial flow is practically independent of the speed and in good agreement with Pohlhausen's theoretical values; Whereas, in transverse flow, cylinders of certain diameter manifest a close relationship with speed, the ratio of the temperature above the air of the body to the adiabatic stagnation temperature decreases with rising speed and then rises again from a Mach number of 0.6. The importance of this "specific temperature" of the body for heat-transfer studies at high speed is discussed.

  3. M-mode and two-dimensional echocardiographic reference values for three Hungarian dog breeds: Hungarian Vizsla, Mudi and Hungarian Greyhound.

    PubMed

    Vörös, Károly; Hetyey, Csaba; Reiczigel, Jeno; Czirok, Gábor Nagy

    2009-06-01

    The aim of the study was to establish normal reference echocardiographic values for three Hungarian dog breeds, and to determine the potential dependence of intracardiac parameters on body weight, age and gender. M-mode and two-dimensional echocardiography were performed on 95 clinically healthy dogs including 45 Hungarian Vizslas, 28 Mudis and 22 Hungarian Greyhounds. Linear intracardiac measurements included interventricular septal thickness (IVS), left ventricular internal diameter (LVID), left ventricular posterior wall thickness (LVPW) both in systole and diastole, as well as left atrial internal diameter (LAD), and aortic diameter (AOD) in early diastole. Fractional shortening (FS), end-diastolic and end-systolic left ventricular volumes (EDV and ESV), as well as LAD:AOD ratio were calculated from the linear parameters. Mean, range and standard deviation of measurements were calculated for each breed. Body weight positively correlated in all three breeds with all left ventricular dimensions, such as IVS d , IVS s , LVID d , LVIDD s , LVPW d and LVPW s parameters. LA values showed positive correlations to body weight in all three breeds. AOD and LA demonstrated a positive correlation with body weight in Hungarian Vizslas and Mudis, whilst the LAD:AOD ratio was related to body weight only in Mudis. Gender did not correlate with any of the measured echocardiographic parameters in any breeds. In Mudis, a positive correlation was found between the LAD: AOD ratio and age, as well as between the LAD: AOD ratio and E point to septal separation (EPSS).

  4. Thermocouple design for measuring temperatures of small insects

    Treesearch

    A.A. Hanson; R.C. Venette

    2013-01-01

    Contact thermocouples often are used to measure surface body temperature changes of insects during cold exposure. However, small temperature changes of minute insects can be difficult to detect, particularly during the measurement of supercooling points. We developed two thermocouple designs, which use 0.51 mm diameter or 0.127 mm diameter copper-constantan wires, to...

  5. Morphometric study of the lumbar spinal canal in the Korean population.

    PubMed

    Lee, H M; Kim, N H; Kim, H J; Chung, I H

    1995-08-01

    The anatomic dimensions of the vertebral body and spinal canal of the lumbar spine were analyzed in Koreans. To determine the normal dimension of the lumbar spinal canal in Koreans, to determine whether there are any racial differences in the morphometry of the lumbar spinal canal, and to provide criteria for diagnosing spinal stenosis in the Far Eastern Asian. Some radiologic and anatomic studies have been conducted regarding the size of the lumbar spinal canal of whites and blacks in western and African countries. One-thousand-eight-hundred measurements were performed on the transverse and sagittal diameters of vertebral bodies and spinal canals using complete sets of 90 lumbar vertebrae. The mean mid-sagittal diameter of the lumbar spinal canal in the Korean population was less than that measured in white and African populations, but there was no significant differences between the Korean, white, and African populations regarding the transverse diameter of the lumbar spinal canal. The mid-sagittal diameter of the lumbar spinal canal is narrowest in the Far Eastern Asian population; the radiologic criteria of spinal stenosis should be reconsidered for these people.

  6. The effect of nozzle-exit-channel shape on resultant fiber diameter in melt-electrospinning

    NASA Astrophysics Data System (ADS)

    Esmaeilirad, Ahmad; Ko, Junghyuk; Rukosuyev, Maxym V.; Lee, Jason K.; Lee, Patrick C.; Jun, Martin B. G.

    2017-01-01

    In recent decades, electrospinning using a molten poly (ε-caprolactone) resin has gained attention for creating fibrous tissue scaffolds. The topography and diameter control of such electrospun microfibers is an important issue for their different applications in tissue engineering. Charge density, initial nozzle-exit-channel cross-sectional area, nozzle to collector distance, viscosity, and processing temperature are the most important input parameters that affect the final electrospun fiber diameters. In this paper we will show that the effect of nozzle-exit-channel shape is as important as the other effective parameters in a resultant fiber diameter. However, to the best of our knowledge, the effect of nozzle-exit-channel shapes on a resultant fiber diameter have not been studied before. Comparing rectangular and circular nozzles with almost the same exit-channel cross-sectional areas in a similar processing condition showed that using a rectangular nozzle resulted in decreasing final fiber diameter up to 50%. Furthermore, the effect of processing temperature on the final fiber topography was investigated.

  7. The Effect of Nose Shape on the Drag of Bodies of Revolution at Zero Angle of Attack

    NASA Technical Reports Server (NTRS)

    Seiff, Alvin; Sandahl, Carl A.

    1951-01-01

    The subject of this paper is the drag of the nose section of bodies of revolution at zero angle of attack. The magnitude of the nose drag in relation to the total drag is very distinctly a function of the body design and the Mach number. It can range from a very small fraction of the total drag of the order of 10 percent to a very large fraction as high as 80 percent. The natural objective of nose design is to minimize the drag, but this objective is not always the primary one. Sometimes other factors overshadow the desire for minimum drag. The most conspicuous example of this is the proposal of guidance engineers that large-diameter spheres and other very blunt shapes be used at the nose tip. This paper will attempt to discuss both phases of the problem, noses for minimum drag and noses with very blunt tips. The state of the theory will also be reviewed and recent theoretical developments described, since the theory still remains a very valuable tool for assaying the effects of compromises in design and departure from shapes for which experimental data are available.

  8. Preparation for Testing a Multi-Bay Box Subjected to Combined Loads

    NASA Technical Reports Server (NTRS)

    Rouse, Marshall; Jegley, Dawn

    2015-01-01

    The COmbined Loads Test System (COLTS) facility at NASA Langley Research Center provides a test capability to help develop validated structures technologies. The test machine was design to accommodate a range of fuselage structures and wing sections and subject them to both quasistatic and cyclic loading conditions. The COLTS facility is capable of testing fuselage barrels up to 4.6 m in diameter and 13.7 m long with combined mechanical, internal pressure, and thermal loads. The COLTS facility is currently being prepared to conduct a combined mechanical and pressure loading for a multi-bay pressure box to experimentally verify the structural performance of a composite structure which is 9.1 meters long and representative of a section of a hybrid wing body fuselage section in support of the Environmentally Responsible Aviation Project at NASA. This paper describes development of the multi-bay pressure box test using the COLTS facility. The multi-bay test article will be subjected to mechanical loads and internal pressure loads up to design ultimate load. Mechanical and pressure loads will be applied independently in some tests and simultaneously in others.

  9. [Difficilina cerebratuli gen. et sp. n. (Eugregarinida: Lecudinidae)--a new gregarine species from the nemertean Cerebratulus barentsi (Nemertini: Cerebratulidae)].

    PubMed

    Simdianov, T G

    2009-01-01

    A new species of aseptate gregarine, Difficilina cerebratuli gen. et sp. n. (order Eugregarinida Leger, 1900; suborder Aseptata Chakravarty, 1960; family Lecudinidae Kamm, 1922) from the gut of the White Sea nemertean Cerebratulus barentsi Bürger, 1895, has been described. The electron and light microscopic data on trophozoites are presented. Their general morphology resembles the representatives of the genus Lecudina, but the features of the epicyte ultrastructure are different from Lecudina and similar to those of the Lankesteria spp. Taxonomy of the described species is discussed. Certain ultrastructural characters are included in its generic and specific diagnoses. Genus Difficilina gen. n. Type species: Difficilina cerebratuli sp. n. Characters of the family. Free trophozoites elongated, anterior end rounded, without hooks or exfoliations, not separated from the rest of the body, with well-developed terminal smooth area. The epicytic folds undulating vertically, in cross sections--monomorphic, finger-shaped, with strongly developed cell-coat, with additional electron-dense axial structure ("middle axis") at the tops; number of rippled dense structurtes and apical filaments 3, the furthers are thick and slightly flattened in diameter. Other stages unknown. In testinal parasites of nemerteans. The new genus differs from Lecudina by presence of smooth area at the apical pole of the body and the epicyte structure: vertically undulating monomorphic finger-shaped (in cross section) epicytic folds, oligomerization of the rippled dense structures and apical filaments, and development of the "middle axis". It also differs from Lankesteria by the shape of the body, vertical undulation of the folds, and non-tunicate host. Difficilina cerebratuli sp. n. Characters of the genus. Free trophozoites slightly bent, up to 250 x 70 microm. Anterior end with less granular cytoplasm; with feebly marked apical papilla encircled by the smooth area. Posterior end pointed. The average height of the epicytic folds is 280 nm, thickness--160 nm, average distance between folds is 130 nm. Endoplasm contains a number of accumulations of the fibrillar matter. Nucleus spherical 14-26 microm in diameter, localized in the middle or in the fore third of the body, carries 1-2 karyosomes of various size. Other stages unknown. TYPE SERIES: Microscopical slide with 7 trophozoites (Bouin, Delafield's haematoxylin) is kept in the Zoological museum of the Moscow State University (collection number: Z-2). In addition, two syntypes are observed with TEM and two other syntypes--with SEM. TYPE HOST: Cerebratulus barentsi Bürger, 1895 (Nemertini: Cerebratulidae). Intestine (?). TYPE LOCALITY: White Sea Biological Station of the Moscow State University, Yeremeyevsky Rapid, Velikaya Salma Strait, Kandalaksha Bay, White Sea.

  10. Small-Body Extensions for the Satellite Orbit Analysis Program (SOAP)

    NASA Technical Reports Server (NTRS)

    Carnright, Robert; Stodden, David; Coggi, John

    2008-01-01

    An extension to the SOAP software allows users to work with tri-axial ellipsoid-based representations of planetary bodies, primarily for working with small, natural satellites, asteroids, and comets. SOAP is a widely used tool for the visualization and analysis of space missions. The small body extension provides the same visualization and analysis constructs for use with small bodies. These constructs allow the user to characterize satellite path and instrument cover information for small bodies in both 3D display and numerical output formats. Tri-axial ellipsoids are geometric shapes the diameters of which are different in each of three principal x, y, and z dimensions. This construct provides a better approximation than using spheres or oblate spheroids (ellipsoids comprising two common equatorial diameters as a distinct polar diameter). However, the tri-axial ellipsoid is considerably more difficult to work with from a modeling perspective. In addition, the SOAP small-body extensions allow the user to actually employ a plate model for highly irregular surfaces. Both tri-axial ellipsoids and plate models can be assigned to coordinate frames, thus allowing for the modeling of arbitrary changes to body orientation. A variety of features have been extended to support tri-axial ellipsoids, including the computation and display of the spacecraft sub-orbital point, ground trace, instrument footprints, and swathes. Displays of 3D instrument volumes can be shown interacting with the ellipsoids. Longitude/latitude grids, contour plots, and texture maps can be displayed on the ellipsoids using a variety of projections. The distance along an arbitrary line of sight can be computed between the spacecraft and the ellipsoid, and the coordinates of that intersection can be plotted as a function of time. The small-body extension supports the same visual and analytical constructs that are supported for spheres and oblate spheroids in SOAP making the implementation of the more complex algorithms largely transparent to the user.

  11. Comparative range of orthodontic wires.

    PubMed

    Ingram, S B; Gipe, D P; Smith, R J

    1986-10-01

    ADA specification No. 32 for determining the range (elastic limit) of orthodontic wires uses the bending of a wire section treated as a cantilever beam. An alternative method for defining the range of orthodontic wires proposed by Waters (1981) is to wrap wire sections around mandrels of varying diameters and measure the deformation imparted after unwrapping. Four brass mandrels with a total of 46 test diameters ranging from 3.5 to 60.0 mm were used in this study. Wire sections 9 cm in length were rolled on the mandrel with a hand lathe. The mandrel cross section required to produce a predetermined amount of deformation (2 mm arc height for a 5 cm chord) was defined as the yield diameter for that particular wire. No individual wire was tested twice so as to avoid introduction of strain history. Test samples of 488 different orthodontic wires supplied by nine commercial distributors were evaluated (a total of 4,747 samples). Stainless steel wires of identical dimensions had a large variation in range, depending on the state of strain hardening and heat treatment. For example, 0.020 inch round wire had yield diameters ranging from 22.8 mm for Australian special plus orange (TP Laboratories) to 42.9 mm for Nubryte gold (G.A.C. International). Chromium cobalt wires had less range than stainless steel before heat treatment, but increased greatly in range after heat treatment. Nitinol (Unitek) had the greatest range of all wires tested (yield diameter of 8.7 mm for 0.016 inch Nitinol). Multistranded stainless steel wires had yield diameters between 9.0 and 14.0 mm.

  12. Functional restoration of the esophagus after peroral endoscopic myotomy for achalasia.

    PubMed

    Huh, Cheal Wung; Youn, Young Hoon; Chung, Hyunsoo; Lee, Yong Chan; Park, Hyojin

    2017-01-01

    Peroral endoscopic myotomy (POEM) is a new efficacious treatment option for achalasia. We propose to define "esophageal remodeling" as the functional restoration of the esophagus that involves decreased lower esophageal sphincter (LES) pressure, recovery of esophageal body peristalsis, and reduction of luminal diameter. The aim of this study was to investigate "esophageal remodeling" after POEM for achalasia. We analyzed data from a prospectively collected database of POEM subjects, which included preoperative and 2-month postoperative Eckardt symptom scores, and results from esophageal high resolution manometry (HRM) and barium esophagogram (BE). We recruited 23 patients (13 male; mean age: 53.9 years) whose preoperative and postoperative HRM and BE results were available, from among 30 patients with achalasia who underwent POEM at two institutions between July 2013 and December 2015. All patients achieved clinical treatment success (Eckardt score≤3). Partial recovery of esophageal body peristalsis was noted in 1/5 patients with type I (20%), 6/11 with type II (54.5%), and 7/7 with type III (100%) achalasia after POEM. Pan-esophageal pressurization disappeared after POEM in 10/11 type II achalasia patients. The average diameter of the esophageal body after POEM was significantly decreased in all types of achalasia. POEM provided excellent clinical symptomatic relief and esophageal remodeling in terms of restoration of peristalsis and reduction in diameter of the esophageal body, especially in patients with type III achalasia.

  13. Influence of time off feed on broiler viscera weight, diameter, and shear.

    PubMed

    Buhr, R J; Northcutt, J K; Lyon, C E; Rowland, G N

    1998-05-01

    The influence of time off feed on broiler viscera weight, intestinal diameter, and shear was studied by subjecting market-age male broilers (42, 44, or 48 d) to incremental feed withdrawal periods (0, 6, 12, 18, or 24 h). Body weight was determined prior to feed withdrawal and at the time of processing. After slaughter, scalding, and defeathering, the abdominal cavity was opened. Diameter and shear of the proventriculus-ventriculus junction, jejunum, and ileum segments were measured, as were gallbladder length and width. Thoracic and abdominal viscera, liver, and ventriculus weights were determined, and liver surface color was measured. Percentage body weight loss increased with longer feed withdrawal periods, as viscera, liver, and ventriculus weights decreased. Gallbladder length increased with time off feed, whereas its width did not change. Diameter of the proventriculus-ventriculus junction, jejunum, and ileum decreased with longer feed withdrawal periods. Shear values for the proventriculus-ventriculus junction, jejunum, and ileum were not influenced by time off feed. Positive correlations (P < 0.05 and r > 0.4) between viscera weight and intestinal diameter were detected. Correlations between all measured parameters and shear values were not significant. Liver color measurements indicated that longer feed withdrawal periods resulted in significant linear decreases in L* (lightness), +a* (redness), and +b* (yellowness). Longer feed withdrawal periods decreased viscera weight and intestinal diameter, which would lower the potential for cutting the intestine during automated evisceration. However, the resulting greater gallbladder length (5 mm) would increase the possibility of bile contamination during evisceration.

  14. System for producing a uniform rubble bed for in situ processes

    DOEpatents

    Galloway, T.R.

    1983-07-05

    A method and a cutter are disclosed for producing a large cavity filled with a uniform bed of rubblized oil shale or other material, for in situ processing. A raise drill head has a hollow body with a generally circular base and sloping upper surface. A hollow shaft extends from the hollow body. Cutter teeth are mounted on the upper surface of the body and relatively small holes are formed in the body between the cutter teeth. Relatively large peripheral flutes around the body allow material to drop below the drill head. A pilot hole is drilled into the oil shale deposit. The pilot hole is reamed into a large diameter hole by means of a large diameter raise drill head or cutter to produce a cavity filled with rubble. A flushing fluid, such as air, is circulated through the pilot hole during the reaming operation to remove fines through the raise drill, thereby removing sufficient material to create sufficient void space, and allowing the larger particles to fill the cavity and provide a uniform bed of rubblized oil shale. 4 figs.

  15. Nozzle insert for mixed mode fuel injector

    DOEpatents

    Lawrence, Keith E [Peoria, IL

    2006-11-21

    A fuel injector includes a homogenous charge nozzle outlet set and a conventional nozzle outlet set controlled respectively, by first and second needle valve members. The homogeneous charged nozzle outlet set is defined by a nozzle insert that is attached to an injector body, which defines the conventional nozzle outlet set. The nozzle insert is a one piece metallic component with a large diameter segment separated from a small diameter segment by an annular engagement surface. One of the needle valve members is guided on an outer surface of the nozzle insert, and the nozzle insert has an interference fit attachment to the injector body.

  16. Constraints on a plume in the mid-mantle beneath the Iceland region from seismic array data

    USGS Publications Warehouse

    Pritchard, M.J.; Foulger, G.R.; Julian, B.R.; Fyen, J.

    2000-01-01

    Teleseismic P waves passing through low-wave-speed bodies in the mantle are refracted, causing anomalies in their propagation directions that can be measured by seismometer arrays. Waves from earthquakes in the eastern Pacific and western North America arriving at the NORSAR array in Norway and at seismic stations in Scotland pass beneath the Iceland region at depths of ~ 1000-2000 km. Waves arriving at NORSAR have anomalous arrival azimuths consistent with a low-wave-speed body at a depth of ~ 1500 km beneath the Iceland-Faeroe ridge with a maximum diameter of ~ 250 km and a maximum wave-speed contrast of ~ 1.5 per cent. This agrees well with whole-mantle tomography results, which image a low-wave-speed body at this location with a diameter of ~ 500 km and a wave-speed anomaly of ~ 0.5 per cent, bearing in mind that whole-mantle tomography, because of its limited resolution, broadens and weakens small anomalies. The observations cannot resolve the location of the body, and the anomaly could be caused in whole or in part by larger bodies farther away, for example by a body imaged beneath Greenland by whole-mantle tomography.

  17. Common determinants of body size and eye size in chickens from an advanced intercross line.

    PubMed

    Prashar, Ankush; Hocking, Paul M; Erichsen, Jonathan T; Fan, Qiao; Saw, Seang Mei; Guggenheim, Jeremy A

    2009-06-15

    Myopia development is characterised by an increased axial eye length. Therefore, identifying factors that influence eye size may provide new insights into the aetiology of myopia. In humans, axial length is positively correlated to height and weight, and in mice, eye weight is positively correlated with body weight. The purpose of this study was to examine the relationship between eye size and body size in chickens from a genetic cross in which alleles with major effects on eye and body size were segregating. Chickens from a cross between a layer line (small body size and eye size) and a broiler line (large body and eye size) were interbred for 10 generations so that alleles for eye and body size would have the chance to segregate independently. At 3 weeks of age, 510 chicks were assessed using in vivo high resolution A-scan ultrasonography and keratometry. Equatorial eye diameter and eye weight were measured after enucleation. The variations in eye size parameters that could be explained by body weight (BW), body length (BL), head width (HW) and sex were examined using multiple linear regression. It was found that BW, BL and HW and sex together predicted 51-56% of the variation in eye weight, axial length, corneal radius, and equatorial eye diameter. By contrast, the same variables predicted only 22% of the variation in lens thickness. After adjusting for sex, the three body size parameters predicted 45-49% of the variation in eye weight, axial length, corneal radius, and eye diameter, but only 0.4% of the variation in lens thickness. In conclusion, about half of the variation in eye size in the chickens of this broiler-layer advanced intercross line is likely to be determined by pleiotropic genes that also influence body size. Thus, mapping the quantitative trait loci (QTL) that determine body size may be useful in understanding the genetic determination of eye size (a logical inference of this result is that the 20 or more genetic variants that have recently been shown to influence human height may also be found to influence axial eye length). Furthermore, adjusting for body size will be essential in mapping pure eye size QTL in this chicken population, and may also have value in mapping eye size QTL in humans.

  18. Maternal effects and larval survival of marbled sole Pseudopleuronectes yokohamae

    NASA Astrophysics Data System (ADS)

    Higashitani, Tomomi; Takatsu, Tetsuya; Nakaya, Mitsuhiro; Joh, Mikimasa; Takahashi, Toyomi

    2007-07-01

    Maternal effects of animals are the phenotypic influences of age, size, and condition of spawners on the survival and phenotypic traits of offspring. To clarify the maternal effects for marbled sole Pseudopleuronectes yokohamae, we investigated the effects of body size, nutrient condition, and growth history of adult females on egg size, larval size, and starvation tolerance, growth, and feeding ability of offspring. The fecundity of adult females was strongly dependent on body size. Path analysis revealed that the mother's total length positively affected mean egg diameter, meaning that large females spawned large eggs. In contrast, the relative growth rate of adult females negatively affected egg diameter. Egg diameters positively affected both notochord length and yolk sac volume of the larvae at hatching. Under starvation conditions, notochord length at hatching strongly and positively affected days of survival at 14 °C but not at 9 °C. Under adequate food conditions (1000 rotifers L - 1 ), the notochord length of larvae 5 days after hatching positively affected feeding rate, implying that large larvae have high feeding ability. In addition, the mean growth rate of larvae between 0 and 15 days increased with increasing egg diameter under homogenous food conditions, suggesting that larvae hatched from large eggs might have a growth advantage for at least to 15 days after hatching. In marbled sole, these relationships (i.e., mother's body size-egg size-larval size-larval resistance to starvation-larval feeding ability) may help explain recruitment variability.

  19. Elasticity standard values of the Achilles tendon assessed with acoustic radiation force impulse elastography on healthy volunteers: a cross section study.

    PubMed

    Wakker, Jonas; Kratzer, Wolfgang; Graeter, Tilmann; Schmidberger, Julian

    2018-05-09

    To determine normal values for acoustic radiation force impulse (ARFI) shear wave elastography of the Achilles tendon. Using the VTIQ mode with the Acuson S3000™ (Siemens Healthcare, Erlangen, Germany), we measured the shear wave velocity (SWV) in m/s and the diameter in mm of both Achilles tendons in 182 healthy volunteers. The tendon was displayed in a sagittal view with a relaxed tendon. The parameters were tested for correlations with the anthropometric data of the subjects, between the genders and different age groups, as well as information obtained from the history, such as smoking and sporting activities. Using a sagittal acoustic window, we determined a mean SWV of 9.09 ± 0.71 m/s for the left Achilles tendon and 9.17 ± 0.61 m/s for the right. There was a significant difference between the results for the right and left side (p < 0.05). The diameter on the left was 4.7 ± 0.9 mm. On the right, it was 4.8 ± 0.9 mm. Likewise there was a significant difference between the results for the diameter of the left and right side (p < 0.05). Neither gender, body mass index (BMI) nor age had a significant effect on either of the measured parameters (p > 0.05). The same goes for the consumption of tobacco and alcohol (p > 0.05). Age, gender, BMI, smoking or the consumption of alcohol did not affect either the elasticity or the diameter of the Achilles tendon.

  20. Determination of vessel cross-sectional area by thresholding in Radon space

    PubMed Central

    Gao, Yu-Rong; Drew, Patrick J

    2014-01-01

    The cross-sectional area of a blood vessel determines its resistance, and thus is a regulator of local blood flow. However, the cross-sections of penetrating vessels in the cortex can be non-circular, and dilation and constriction can change the shape of the vessels. We show that observed vessel shape changes can introduce large errors in flux calculations when using a single diameter measurement. Because of these shape changes, typical diameter measurement approaches, such as the full-width at half-maximum (FWHM) that depend on a single diameter axis will generate erroneous results, especially when calculating flux. Here, we present an automated method—thresholding in Radon space (TiRS)—for determining the cross-sectional area of a convex object, such as a penetrating vessel observed with two-photon laser scanning microscopy (2PLSM). The thresholded image is transformed back to image space and contiguous pixels are segmented. The TiRS method is analogous to taking the FWHM across multiple axes and is more robust to noise and shape changes than FWHM and thresholding methods. We demonstrate the superior precision of the TiRS method with in vivo 2PLSM measurements of vessel diameter. PMID:24736890

  1. [Ultrasonic measurements of fetal thalamus, caudate nucleus and lenticular nucleus in prenatal diagnosis].

    PubMed

    Yang, Ruiqi; Wang, Fei; Zhang, Jialing; Zhu, Chonglei; Fan, Limei

    2015-05-19

    To establish the reference values of thalamus, caudate nucleus and lenticular nucleus diameters through fetal thalamic transverse section. A total of 265 fetuses at our hospital were randomly selected from November 2012 to August 2014. And the transverse and length diameters of thalamus, caudate nucleus and lenticular nucleus were measured. SPSS 19.0 statistical software was used to calculate the regression curve of fetal diameter changes and gestational weeks of pregnancy. P < 0.05 was considered as having statistical significance. The linear regression equation of fetal thalamic length diameter and gestational week was: Y = 0.051X+0.201, R = 0.876, linear regression equation of thalamic transverse diameter and fetal gestational week was: Y = 0.031X+0.229, R = 0.817, linear regression equation of fetal head of caudate nucleus length diameter and gestational age was: Y = 0.033X+0.101, R = 0.722, linear regression equation of fetal head of caudate nucleus transverse diameter and gestational week was: R = 0.025 - 0.046, R = 0.711, linear regression equation of fetal lentiform nucleus length diameter and gestational week was: Y = 0.046+0.229, R = 0.765, linear regression equation of fetal lentiform nucleus diameter and gestational week was: Y = 0.025 - 0.05, R = 0.772. Ultrasonic measurement of diameter of fetal thalamus caudate nucleus, and lenticular nucleus through thalamic transverse section is simple and convenient. And measurements increase with fetal gestational weeks and there is linear regression relationship between them.

  2. High-Speed Schlieren Movies of the Flow About Reefed Parachute Models Towed at Supersonic Speeds Behind a Conical Body (4.875 Inches in Diameter). Drag Values Based on the Unreefed Diameter of 1.73 F. Porosity of Unreefed Parachute is 28 Percent.

    NASA Technical Reports Server (NTRS)

    1960-01-01

    Flexible parachute models reefed to one-eighth, one-fourth, one-third, and four tenths of its diameter were towed at speeds of Mach 1.80, 2.00, 2.20 and 2.87. Towline lengths tested were 23.40, 24.38, 26.81, and 29.25 inches. High-speed Schlieren movies of the flow are shown.

  3. Tethers as Debris: Simulating Impacts of Tether Fragments on Shuttle Tiles

    NASA Technical Reports Server (NTRS)

    Evans, Steven W.

    2004-01-01

    The SPHC hydrodynamic code was used to simulate impacts of Kevlar and aluminum projectiles on a model of the LI-900 type insulating tiles used on Space Shuffle Orbiters The intent was to examine likely damage that such tiles might experience if impacted by orbital debris consisting of tether fragments. Projectile speeds ranged from 300 meters per second to 10 kilometers per second. Damage is characterized by penetration depth, tile surface-hole diameter, tile body-cavity diameter, coating fracture diameter, tether and cavity wall material phases, and deformation of the aluminum backwall.

  4. Whole-bone scaling of the avian pelvic limb.

    PubMed

    Doube, Michael; Yen, Stephanie C W; Kłosowski, Michał M; Farke, Andrew A; Hutchinson, John R; Shefelbine, Sandra J

    2012-07-01

    Birds form the largest extant group of bipedal animals and occupy a broad range of body masses, from grams to hundreds of kilograms. Additionally, birds occupy distinct niches of locomotor behaviour, from totally flightless strong runners such as the ratites (moa, kiwi, ostrich) to birds that may walk, dabble on water or fly. We apply a whole-bone approach to investigate allometric scaling trends in the pelvic limb bones (femur, tibiotarsus, tarsometatarsus) from extant and recently extinct birds of greatly different size, and compare scaling between birds in four locomotor groups; flightless, burst-flying, dabbling and flying. We also compare scaling of birds' femoral cross-sectional properties to data previously collected from cats. Scaling exponents were not significantly different between the different locomotor style groups, but elevations of the scaling relationships revealed that dabblers (ducks, geese, swans) have particularly short and slender femora compared with other birds of similar body mass. In common with cats, but less pronounced in birds, the proximal and distal extrema of the bones scaled more strongly than the diaphysis, and in larger birds the diaphysis occupied a smaller proportion of bone length than in smaller birds. Cats and birds have similar femoral cross-sectional area (CSA) for the same body mass, yet birds' bone material is located further from the bone's long axis, leading to higher second and polar moments of area and a greater inferred resistance to bending and twisting. The discrepancy in the relationship between outer diameter to CSA may underlie birds' reputation for having 'light' bones. © 2012 The Authors. Journal of Anatomy © 2012 Anatomical Society.

  5. Whole-bone scaling of the avian pelvic limb

    PubMed Central

    Doube, Michael; Yen, Stephanie C W; Kłosowski, Michał M; Farke, Andrew A; Hutchinson, John R; Shefelbine, Sandra J

    2012-01-01

    Birds form the largest extant group of bipedal animals and occupy a broad range of body masses, from grams to hundreds of kilograms. Additionally, birds occupy distinct niches of locomotor behaviour, from totally flightless strong runners such as the ratites (moa, kiwi, ostrich) to birds that may walk, dabble on water or fly. We apply a whole-bone approach to investigate allometric scaling trends in the pelvic limb bones (femur, tibiotarsus, tarsometatarsus) from extant and recently extinct birds of greatly different size, and compare scaling between birds in four locomotor groups; flightless, burst-flying, dabbling and flying. We also compare scaling of birds’ femoral cross-sectional properties to data previously collected from cats. Scaling exponents were not significantly different between the different locomotor style groups, but elevations of the scaling relationships revealed that dabblers (ducks, geese, swans) have particularly short and slender femora compared with other birds of similar body mass. In common with cats, but less pronounced in birds, the proximal and distal extrema of the bones scaled more strongly than the diaphysis, and in larger birds the diaphysis occupied a smaller proportion of bone length than in smaller birds. Cats and birds have similar femoral cross-sectional area (CSA) for the same body mass, yet birds’ bone material is located further from the bone’s long axis, leading to higher second and polar moments of area and a greater inferred resistance to bending and twisting. The discrepancy in the relationship between outer diameter to CSA may underlie birds’ reputation for having ‘light’ bones. PMID:22606941

  6. Age-dependence of the optomechanical responses of ex vivo human lenses from India and the USA, and the force required to produce these in a lens stretcher: the similarity to in vivo disaccommodation

    PubMed Central

    Augusteyn, Robert C; Mohamed, Ashik; Nankivil, Derek; Veerendranath, Pesala; Arrieta, Esdras; Taneja, Mukesh; Manns, Fabrice; Ho, Arthur; Parel, Jean-Marie

    2011-01-01

    The purpose of this study was to study the age-dependence of the optomechanical properties of human lenses during simulated disaccommodation in a mechanical lens stretcher, designed to determine accommodative forces as a function of stretch distance, to compare the results with in vivo disaccommodation and to examine whether differences exist between eyes harvested in the USA and India. Post-mortem human eyes obtained in the USA (n=46, age = 6 to 83 years) and India (n=91, age = 1 day to 85 years) were mounted in an optomechanical lens stretching system and dissected to expose the lens complete with its accommodating framework, including zonules, ciliary body, anterior vitreous and a segmented rim of sclera. Disaccommodation was simulated through radial stretching of the sectioned globe by 2 mm in increments of 0.25 mm. The load, inner ciliary ring diameter, lens equatorial diameter, central thickness and power were measured at each step. Changes in these parameters were examined as a function of age, as were the dimension/load and power/load responses. Unstretched lens diameter and thickness increased over the whole age range examined and were indistinguishable from those of in vivo lenses as well as those of in vitro lenses freed from zonular attachments. Stretching increased the diameter and decreased the thickness in all lenses examined but the amount of change decreased with age. Unstretched lens power decreased with age and the accommodative amplitude decreased to zero by age 45-50. The load required to produce maximum stretch was independent of age (median 80 mN) whereas the change in lens diameter and power per unit load decreased significantly with age. The age related changes in the properties of human lenses, as observed in the lens stretching device, are similar to those observed in vivo and are consistent with the classical Helmholtz theory of accommodation. The response of lens diameter and power to disaccommodative (stretching) forces decreases with age, consistent with lens nuclear stiffening. PMID:21658404

  7. Improved patient size estimates for accurate dose calculations in abdomen computed tomography

    NASA Astrophysics Data System (ADS)

    Lee, Chang-Lae

    2017-07-01

    The radiation dose of CT (computed tomography) is generally represented by the CTDI (CT dose index). CTDI, however, does not accurately predict the actual patient doses for different human body sizes because it relies on a cylinder-shaped head (diameter : 16 cm) and body (diameter : 32 cm) phantom. The purpose of this study was to eliminate the drawbacks of the conventional CTDI and to provide more accurate radiation dose information. Projection radiographs were obtained from water cylinder phantoms of various sizes, and the sizes of the water cylinder phantoms were calculated and verified using attenuation profiles. The effective diameter was also calculated using the attenuation of the abdominal projection radiographs of 10 patients. When the results of the attenuation-based method and the geometry-based method shown were compared with the results of the reconstructed-axial-CT-image-based method, the effective diameter of the attenuation-based method was found to be similar to the effective diameter of the reconstructed-axial-CT-image-based method, with a difference of less than 3.8%, but the geometry-based method showed a difference of less than 11.4%. This paper proposes a new method of accurately computing the radiation dose of CT based on the patient sizes. This method computes and provides the exact patient dose before the CT scan, and can therefore be effectively used for imaging and dose control.

  8. Thermal radiation from large bolides and impact plumes

    NASA Astrophysics Data System (ADS)

    Svetsov, V.; Shuvalov, V.

    2017-09-01

    Numerical simulations of the impacts of asteroids and comets from 20 m to 3 km in diameter have been carried out and thermal radiation fluxes on the ground and luminous efficiencies of the impacts have been calculated. It was assumed that the cosmic objects have no strength, deform, fragment, and vaporize in the atmosphere. After the impact on the ground, formation of craters and plumes was simulated taking into account internal friction of destroyed rocks and a wake formed in the atmosphere. The equations of radiative transfer, added to the equations of gas dynamics, were used in the approximation of radiative heat diffusion or, if the Rosseland optical depth of a radiating volume of gas and vapor was less than unity, in the approximation of volume emission. Radiation fluxes on the Earth's surface were calculated by integrating the equation of radiative transfer along rays passing through a luminous area. Direct thermal radiation from fireballs and impact plumes produced by asteroids and comets larger than 50 m in diameter is dangerous for people, animals, plants, economic objects. Forest fires can be ignited on the ground within a radius of roughly 1000 times the body's diameter (for diameters of the order or smaller than 1 km), 50-m-diameter bodies can ignite forest fires within a radius of up to 40 km and 3-km asteroids - within 1700 km.

  9. Impact of Chronic Rheumatic Valve Diseases on Large Vessels.

    PubMed

    Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet

    2016-01-01

    BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p <0.001). The mean diameter of the IVC (indexed to BSA) was 1.69 ± 0.73 for patients and 1.38 ± 0.35 cm for controls (p <0.001). There was a significant positive correlation between mitral valve mean gradient and IVC diameter (p = 0.01, r = 0.18). There were also strong associations between the mitral valve area and the diameters of the DA (p = 0.001, r = -0.239) and IVC (p <0.001, r = -0.246). CONCLUSION: Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.

  10. Estimation of body mass index from the metrics of the first metatarsal

    NASA Astrophysics Data System (ADS)

    Dunn, Tyler E.

    Estimation of the biological profile from as many skeletal elements as possible is a necessity in both forensic and bioarchaeological contexts; this includes non-standard aspects of the biological profile, such as body mass index (BMI). BMI is a measure that allows for understanding of the composition of an individual and is traditionally divided into four groups: underweight, normal weight, overweight, and obese. BMI estimation incorporates both estimation of stature and body mass. The estimation of stature from skeletal elements is commonly included into the standard biological profile but the estimation of body mass needs to be further statistically validated to be consistently included. The bones of the foot, specifically the first metatarsal, may have the ability to estimate BMI given an allometric relationship to stature and the mechanical relationship to body mass. There are two commonly used methods for stature estimation, the anatomical method and the regression method. The anatomical method takes into account all of the skeletal elements that contribute to stature while the regression method relies on the allometric relationship between a skeletal element and living stature. A correlation between the metrics of the first metatarsal and living stature has been observed, and proposed as a method for valid stature estimation from the boney foot (Byers et al., 1989). Body mass estimation from skeletal elements relies on two theoretical frameworks: the morphometric and the mechanical approaches. The morphometric approach relies on the size relationship of the individual to body mass; the basic relationship between volume, density, and weight allows for body mass estimation. The body is thought of as a cylinder, and in order to understand the volume of this cylinder the diameter is needed. A commonly used proxy for this in the human body is skeletal bi-iliac breadth from rearticulated pelvic girdle. The mechanical method of body mass estimation relies on the ideas of biomechanical bone remodeling; the elements of the skeleton that are under higher forces, including weight, will remodel to minimize stress. A commonly used metric for the mechanical method of body mass estimation is the diameter of the head of the femur. The foot experiences nearly the entire weight force of the individual at any point in the gait cycle and is subject to the biomechanical remodeling that this force would induce. Therefore, the application of the mechanical framework for body mass estimation could stand true for the elements of the foot. The morphometric and mechanical approaches have been validated against one another on a large, geographically disparate population (Auerbach and Ruff, 2004), but have yet to be validated on a sample of known body mass. DeGroote and Humphrey (2011) test the ability of the first metatarsal to estimate femoral head diameter, body mass, and femoral length. The estimated femoral head diameter from the first metatarsal is used to estimate body mass via the morphometric approach and the femoral length is used to estimate living stature. The authors find that body mass and stature estimation methods from more commonly used skeletal elements compared well with the methods developed from the first metatarsal. This study examines 388 `White' individuals from the William M. Bass donated skeletal collection to test the reliability of the body mass estimates from femoral head diameter and bi-iliac breadth, stature from maximum femoral length, and body mass and stature from the metrics of the first metatarsal. This sample included individuals from all four of the BMI classes. This study finds that all of the skeletal indicators compare well with one another; there is no statistical difference in the stature estimates from the first metatarsal and the maximum length of the femur, and there is no statistical between all three of the body mass estimation methods. When compared to the forensic estimates of stature neither of the tested methods had statistical difference. Conversely, when the body mass estimates are compared to forensic body mass there was a statistical difference and when further investigated the most difference in the body mass estimates was in the extremes of body mass (the underweight and obese categories). These findings indicate that the estimation of stature from both the maximum femoral length and the metrics of the metatarsal are accurate methods. Furthermore, the estimation of body mass is accurate when the individual is in the middle range of the BMI spectrum while these methods for outlying individuals are inaccurate. These findings have implications for the application of stature and body mass estimation in the fields of bioarchaeology, forensic anthropology, and paleoanthropology.

  11. Nature and evolution of the meteorite parent bodies: Evidence from petrology and metallurgy

    NASA Technical Reports Server (NTRS)

    Wood, J. A.

    1978-01-01

    The physical as well as chemical properties of the meteorite parent bodies are reviewed and it is concluded that many differentiated meteorites were likely formed in asteroidal-sized parents. A new model is developed for the formation of pallasites at the interface between an iron core and olivine mantle in differentiated bodies only about 10 km in diameter, which are later incorporated into a second generation of larger (100 km) parent bodies.

  12. Whispering Gallery Optical Resonator Spectroscopic Probe and Method

    NASA Technical Reports Server (NTRS)

    Anderson, Mark S. (Inventor)

    2014-01-01

    Disclosed herein is a spectroscopic probe comprising at least one whispering gallery mode optical resonator disposed on a support, the whispering gallery mode optical resonator comprising a continuous outer surface having a cross section comprising a first diameter and a second diameter, wherein the first diameter is greater than the second diameter. A method of measuring a Raman spectrum and an Infra-red spectrum of an analyte using the spectroscopic probe is also disclosed.

  13. Effects of acute administration of ethanol on the rat adrenal cortex.

    PubMed

    Milovanović, Tatjana; Budec, Mirela; Balint-Perić, Ljiljana; Koko, Vesna; Todorović, Vera

    2003-09-01

    The purpose of this study was to investigate the effect of a single dose of ethanol on rat adrenal cortex and to determine whether the estrous cycle can influence this effect of ethanol. Adult female Wistar rats showing proestrus or diestrus Day 1 (n = 12) were treated intraperitoneally with ethanol (4 g/kg body weight). Untreated (n = 15) and saline-injected (n = 14) rats were used as controls. The animals were sacrificed by decapitation 0.5 hour after ethanol administration. Stereological analysis was performed on paraffin sections of adrenal glands stained with AZAN, and the following parameters were determined: absolute volume of the zona glomerulosa, the zona fasciculata and the zona reticularis, numerical density, volume and the mean diameter of adrenocortical cells and of their nuclei, and diameter and length of capillaries. The diameter and volume of adrenocortical cells in the zona fasciculata and the zona reticularis were significantly increased by acute ethanol treatment at proestrus. In the same group of animals, a single dose of ethanol induced significant decrease in numerical density of adrenocortical cells and of their nuclei in all three zones. Increased length of capillaries of the zona fasciculata as well as enhanced level of serum corticosterone was found in ethanol-treated rats at both phases of the estrous cycle, proestrus and diestrus Day 1. The obtained results indicate that a single dose of ethanol activates adrenal cortex in female rats and that the effect is more pronounced on morphometric parameters at proestrus.

  14. Immunogold staining procedure for the localisation of regulatory peptides.

    PubMed

    Varndell, I M; Tapia, F J; Probert, L; Buchan, A M; Gu, J; De Mey, J; Bloom, S R; Polak, J M

    1982-01-01

    The use of protein A- and IgG-conjugated colloidal gold staining methods for the immuno-localisation of peptide hormones and neurotransmitters at light- and electron microscope level are described and discussed. Bright-field and dark-ground illumination modes have been used to visualise the gold-labelled antigenic sites at the light microscope level. Immunogold staining procedures at the ultrastructural level using region-specific antisera have been adopted to localise specific molecular forms of peptides including gastrin (G17 and G34), glucagon and pro-glucagon, insulin and pro-insulin, in normal tissue and in tumours of the gastroenteropancreatic system. Similar methods have been used to demonstrate the heterogeneity of p-type nerves in the enteric nervous system. Vasoactive intestinal polypeptide (VIP) has been localised to granular sites (mean +/- S.D. granule diameter = 98 +/- 19 nm) in nerve terminals of the enteric plexuses and in tumour cells of diarrhoeogenic VIP-producing neoplasias (mean +/- S.D. granule diameter = 126 +/- 37 nm) using immunogold procedures applied to ultraviolet-cured ultrathin sections. Co-localisation of amines and peptides in carotid body type I cells and in chromaffin cells of normal adrenal medulla and phaeochromocytomas has also been demonstrated. Advantages of the immunogold procedures over alternative immunocytochemical techniques are discussed.

  15. 21 CFR 888.4150 - Calipers for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ....4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... or diameter of a part of the body or the distance between two body surfaces, such as for measuring an excised skeletal specimen to determine the proper replacement size of a prosthesis. (b) Classification...

  16. 21 CFR 888.4150 - Calipers for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ....4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... or diameter of a part of the body or the distance between two body surfaces, such as for measuring an excised skeletal specimen to determine the proper replacement size of a prosthesis. (b) Classification...

  17. 21 CFR 888.4150 - Calipers for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ....4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... or diameter of a part of the body or the distance between two body surfaces, such as for measuring an excised skeletal specimen to determine the proper replacement size of a prosthesis. (b) Classification...

  18. 21 CFR 888.4150 - Calipers for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... or diameter of a part of the body or the distance between two body surfaces, such as for measuring an excised skeletal specimen to determine the proper replacement size of a prosthesis. (b) Classification...

  19. Small head size and delayed body weight growth in wild Japanese monkey fetuses after the Fukushima Daiichi nuclear disaster.

    PubMed

    Hayama, Shin-Ichi; Tsuchiya, Moe; Ochiai, Kazuhiko; Nakiri, Sachie; Nakanishi, Setsuko; Ishii, Naomi; Kato, Takuya; Tanaka, Aki; Konno, Fumiharu; Kawamoto, Yoshi; Omi, Toshinori

    2017-06-14

    To evaluate the biological effect of the Fukushima Daiichi nuclear disaster, relative differences in the growth of wild Japanese monkeys (Macaca fuscata) were measured before and after the disaster of 2011 in Fukushima City, which is approximately 70 km from the nuclear power plant, by performing external measurements on fetuses collected from 2008 to 2016. Comparing the relative growth of 31 fetuses conceived prior to the disaster and 31 fetuses conceived after the disaster in terms of body weight and head size (product of the occipital frontal diameter and biparietal diameter) to crown-rump length ratio revealed that body weight growth rate and proportional head size were significantly lower in fetuses conceived after the disaster. No significant difference was observed in nutritional indicators for the fetuses' mothers. Accordingly, radiation exposure could be one factor contributed to the observed growth delay in this study.

  20. Impact of event positioning algorithm on performance of a whole-body PET scanner using one-to-one coupled detectors

    NASA Astrophysics Data System (ADS)

    Surti, S.; Karp, J. S.

    2018-03-01

    The advent of silicon photomultipliers (SiPMs) has introduced the possibility of increased detector performance in commercial whole-body PET scanners. The primary advantage of these photodetectors is the ability to couple a single SiPM channel directly to a single pixel of PET scintillator that is typically 4 mm wide (one-to-one coupled detector design). We performed simulation studies to evaluate the impact of three different event positioning algorithms in such detectors: (i) a weighted energy centroid positioning (Anger logic), (ii) identifying the crystal with maximum energy deposition (1st max crystal), and (iii) identifying the crystal with the second highest energy deposition (2nd max crystal). Detector simulations performed with LSO crystals indicate reduced positioning errors when using the 2nd max crystal positioning algorithm. These studies are performed over a range of crystal cross-sections varying from 1  ×  1 mm2 to 4  ×  4 mm2 as well as crystal thickness of 1 cm to 3 cm. System simulations were performed for a whole-body PET scanner (85 cm ring diameter) with a long axial FOV (70 cm long) and show an improvement in reconstructed spatial resolution for a point source when using the 2nd max crystal positioning algorithm. Finally, we observe a 30-40% gain in contrast recovery coefficient values for 1 and 0.5 cm diameter spheres when using the 2nd max crystal positioning algorithm compared to the 1st max crystal positioning algorithm. These results show that there is an advantage to implementing the 2nd max crystal positioning algorithm in a new generation of PET scanners using one-to-one coupled detector design with lutetium based crystals, including LSO, LYSO or scintillators that have similar density and effective atomic number as LSO.

  1. Functional restoration of the esophagus after peroral endoscopic myotomy for achalasia

    PubMed Central

    Huh, Cheal Wung; Youn, Young Hoon; Chung, Hyunsoo; Lee, Yong Chan; Park, Hyojin

    2017-01-01

    Purpose Peroral endoscopic myotomy (POEM) is a new efficacious treatment option for achalasia. We propose to define “esophageal remodeling” as the functional restoration of the esophagus that involves decreased lower esophageal sphincter (LES) pressure, recovery of esophageal body peristalsis, and reduction of luminal diameter. The aim of this study was to investigate “esophageal remodeling” after POEM for achalasia. Materials and methods We analyzed data from a prospectively collected database of POEM subjects, which included preoperative and 2-month postoperative Eckardt symptom scores, and results from esophageal high resolution manometry (HRM) and barium esophagogram (BE). We recruited 23 patients (13 male; mean age: 53.9 years) whose preoperative and postoperative HRM and BE results were available, from among 30 patients with achalasia who underwent POEM at two institutions between July 2013 and December 2015. Results All patients achieved clinical treatment success (Eckardt score≤3). Partial recovery of esophageal body peristalsis was noted in 1/5 patients with type I (20%), 6/11 with type II (54.5%), and 7/7 with type III (100%) achalasia after POEM. Pan-esophageal pressurization disappeared after POEM in 10/11 type II achalasia patients. The average diameter of the esophageal body after POEM was significantly decreased in all types of achalasia. Conclusion POEM provided excellent clinical symptomatic relief and esophageal remodeling in terms of restoration of peristalsis and reduction in diameter of the esophageal body, especially in patients with type III achalasia. PMID:28542509

  2. Simulation of a supersonic flow around a body with a frontal gas-permeable insert by using a skeleton model of a highly porous cellular material

    NASA Astrophysics Data System (ADS)

    Poplavskaya, T. V.; Kirilovskiy, S. V.; Mironov, S. G.

    2017-10-01

    Numerical simulation of supersonic flow past a cylinder with a frontal gas-permeable insert is performed using the skeleton model of a highly porous cellular material. Numerical simulation was carried out within the framework of two-dimensional RANS equations written in an axisymmetric form. The skeleton model is a system of coaxial rings of different diameters, arranged in staggered order. The calculations were carried out in a wide range of determining parameters: Mach numbers M∞ = 3, 4.85 and 7, unit Reynolds numbers Re1∞ = 13.8×105 ÷ 13.8×106 m-1, the cylinder diameter 6÷40mm, the length of the porous insert 3÷45mm, the cell diameter of 1 and 3 mm. The results of the calculations are consistent with the available experimental data. The applicability of the skeleton model for the description of supersonic flow around axisymmetric bodies with front inserts from cellular-porous materials is shown.

  3. Multiple double cross-section transmission electron microscope sample preparation of specific sub-10 nm diameter Si nanowire devices.

    PubMed

    Gignac, Lynne M; Mittal, Surbhi; Bangsaruntip, Sarunya; Cohen, Guy M; Sleight, Jeffrey W

    2011-12-01

    The ability to prepare multiple cross-section transmission electron microscope (XTEM) samples from one XTEM sample of specific sub-10 nm features was demonstrated. Sub-10 nm diameter Si nanowire (NW) devices were initially cross-sectioned using a dual-beam focused ion beam system in a direction running parallel to the device channel. From this XTEM sample, both low- and high-resolution transmission electron microscope (TEM) images were obtained from six separate, specific site Si NW devices. The XTEM sample was then re-sectioned in four separate locations in a direction perpendicular to the device channel: 90° from the original XTEM sample direction. Three of the four XTEM samples were successfully sectioned in the gate region of the device. From these three samples, low- and high-resolution TEM images of the Si NW were taken and measurements of the NW diameters were obtained. This technique demonstrated the ability to obtain high-resolution TEM images in directions 90° from one another of multiple, specific sub-10 nm features that were spaced 1.1 μm apart.

  4. Site-Specific Advantages in Skeletal Geometry and Strength at the Proximal Femur and Forearm in Young Female Gymnasts

    PubMed Central

    Dowthwaite, Jodi N.; Rosenbaum, Paula F.; Scerpella, Tamara A.

    2012-01-01

    Purpose We evaluated site-specific skeletal adaptation to loading during growth,comparing radius (RAD) and femoral neck (FN) DXA scans in young female gymnasts (GYM) and non-gymnasts (NON). Methods Subjects from an ongoing longitudinal study (8-26 yrs old) underwent annual DXA scans (proximal femur, forearm, total body) and anthropometry, completing maturity and physical activity questionnaires. This cross-sectional analysis used the most recent data meeting the following criteria: gynecological age ≤2.5 yrs post-menarche; GYM annual mean gymnastic exposure ≥5.0 h/wk in the prior year. Bone geometric and strength indices were derived from scans for 173 subjects (8-17 yrs old) via hip structural analysis (femoral narrow neck, NN) and similar radius formulae (1/3 and Ultradistal (UD)). Maturity was coded as M1 (Tanner I breast), M2 (pre-menarche, ≥Tanner II breast) or M3 (post-menarche). ANOVA and chi square compared descriptive data. Two factor ANCOVA adjusted for age, height, total body non-bone lean mass and percent body fat; significance was tested for main effects and interactions between gymnastic exposure and maturity. Results At the distal radius, GYM means were significantly greater than NON means for all variables (p<0.05). At the proximal femur, GYM exhibited narrower periosteal and endosteal dimensions, but greater indices of cortical thickness, BMC, aBMD and section modulus, with lower buckling ratio (p <0.05). However, significant interactions between maturity and loading were detected for the following: 1) FN bone mineral content (BMC), NN buckling ratio (GYM BMC advantages only in M1 and M3; for BMC and buckling ratio, M1 advantages were greatest; 2) 1/3 radius BMC, width, endosteal diameter, cortical cross-sectional area, section modulus (GYM advantages primarily post-menarche); 3) UD radius BMC and axial compressive strength (GYM advantages were larger with greater maturity, greatest post-menarche). Conclusions Maturity-specific comparisons suggested site-specific skeletal adaptation to loading during growth, with greater advantages at the radius versus the proximal femur. At the radius, GYM advantages included greater bone width, cortical cross-sectional area and cortical thickness; in contrast, at the femoral neck, GYM bone tissue cross-sectional area and cortical thickness were greater, but bone width was narrower than in NON. Future longitudinal analyses will evaluate putative maturity-specific differences. PMID:22342799

  5. Birth weight and optic nerve head parameters.

    PubMed

    Samarawickrama, Chameen; Huynh, Son C; Liew, Gerald; Burlutsky, George; Mitchell, Paul

    2009-06-01

    To assess the relationship of birth weight, birth length, and head circumference as proxy markers of intrauterine growth, cup/disc ratio, and other optic disc parameters measured using optical coherence tomography (OCT). Population-based cross sectional analysis. The Sydney Childhood Eye Study examined 2353 primarily 12-year-old children from 21 randomly selected secondary schools during 2003 to 2005. Of 2353 children examined, 2134 (90.7%) had OCT scans (Zeiss Stratus OCT, Carl Zeiss Meditec, Dublin, CA) and are included in this study. The "fast" optic disc scan protocol was used. Birth weight, birth length, and head circumference were ascertained from health records. Height and weight were measured using standardized protocols, body mass index (BMI) was defined as weight (kilograms)/ height squared (meters), and sociodemographic information was collected in a questionnaire completed by parents. Low birth weight was defined as birth weight

  6. Brain Perfusion and Arterial Blood Flow Velocity During Prolonged Body Tilting.

    PubMed

    Montero, David; Rauber, Sven

    2016-08-01

    It remains unknown whether brain perfusion is preserved and mirrored by middle cerebral blood flow velocity (MCA BFV) during prolonged changes in body posture. Herein, we examined the impact of sustained (180 min) 30° head-up (HUT) and head-down (HDT) tilt on brain perfusion, as determined by MCA BFV and blood flow in the extracranial arteries. In 10 healthy male subjects, arterial diameters, BFVs, and blood flows were determined in the left internal carotid (ICA) and vertebral (VA) arteries using duplex Doppler ultrasound in supine rest, and 5, 20, 60, 120, and 180 min following 30° HUT and HDT. MCA BFV was recorded throughout with transcranial Doppler ultrasound. ICA as well as VA diameters and blood flows were unaltered during HUT. Likewise, brain blood flow and MCA BFV were preserved with HUT. In the HDT protocol, ICA and VA diameters were gradually increased, although ICA, VA, and brain blood flows were preserved. MCA BFV was progressively reduced during HDT. In addition, MCA BFV was positively associated with ICA BFV (β = 0.9) and negatively associated with ICA diameter (β = -125.5). MCA BFV was positively associated with brain blood flow during HUT (β = 0.2) but not HDT. Brain perfusion is preserved whereas MCA BFV is progressively decreased and associated with extracranial arterial BFV during sustained 30° HDT. Therefore, MCA BFV may not be a surrogate of brain perfusion in conditions including prolonged HDT. Montero D, Rauber S. Brain perfusion and arterial blood flow velocity during prolonged body tilting. Aerosp Med Hum Perform. 2016; 87(8):682-687.

  7. Bone microstructure and the evolution of growth patterns in Permo-Triassic therocephalians (Amniota, Therapsida) of South Africa

    PubMed Central

    Botha-Brink, Jennifer

    2014-01-01

    Therocephalians were a speciose clade of nonmammalian therapsids whose ecological diversity and survivorship of the end-Permian mass extinction offer the potential to investigate the evolution of growth patterns across the clade and their underlying influences on post-extinction body size reductions, or ‘Lilliput effects’. We present a phylogenetic survey of limb bone histology and growth patterns in therocephalians from the Middle Permian through Middle Triassic of the Karoo Basin, South Africa. Histologic sections were prepared from 80 limb bones representing 11 genera of therocephalians. Histologic indicators of skeletal growth, including cortical vascularity (%CV) and mean primary osteon diameters (POD), were evaluated in a phylogenetic framework and assessed for correlations with other biologically significant variables (e.g., size and robusticity). Changes in %CV and POD correlated strongly with evolutionary changes in body size (i.e., smaller-bodied descendants tended to have lower %CV than their larger-bodied ancestors across the tree). Bone wall thickness tended to be high in early therocephalians and lower in the gracile-limbed baurioids, but showed no general correlation with cross-sectional area or degree of vascularity (and, thus, growth). Clade-level patterns, however, deviated from previously studied within-lineage patterns. For example, Moschorhinus, one of few therapsid genera to have survived the extinction boundary, demonstrated higher %CV in the Triassic than in the Permian despite its smaller size in the extinction aftermath. Results support a synergistic model of size reductions for Triassic therocephalians, influenced both by within-lineage heterochronic shifts in survivor taxa (as reported in Moschorhinus and the dicynodont Lystrosaurus) and phylogenetically inferred survival of small-bodied taxa that had evolved short growth durations (e.g., baurioids). These findings mirror the multi-causal Lilliput patterns described in marine faunas, but contrast with skeletochronologic studies that suggest slow, prolonged shell secretion over several years in marine benthos. Applications of phylogenetic comparative methods to new histologic data will continue to improve our understanding of the evolutionary dynamics of growth and body size shifts during mass extinctions and recoveries. PMID:24765566

  8. Gender, smoking, body size, and aneurysm geometry influence the biomechanical rupture risk of abdominal aortic aneurysms as estimated by finite element analysis.

    PubMed

    Lindquist Liljeqvist, Moritz; Hultgren, Rebecka; Siika, Antti; Gasser, T Christian; Roy, Joy

    2017-04-01

    Finite element analysis (FEA) has been suggested to be superior to maximal diameter measurements in predicting rupture of abdominal aortic aneurysms (AAAs). Our objective was to investigate to what extent previously described rupture risk factors were associated with FEA-estimated rupture risk. One hundred forty-six patients with an asymptomatic AAA of a 40- to 60-mm diameter were retrospectively identified and consecutively included. The patients' computed tomography angiograms were analyzed by FEA without (neutral) and with (specific) input of patient-specific mean arterial pressure (MAP), gender, family history, and age. The maximal wall stress/wall strength ratio was described as a rupture risk equivalent diameter (RRED), which translated this ratio into an average aneurysm diameter of corresponding rupture risk. In multivariate linear regression, RRED neutral increased with female gender (3.7 mm; 95% confidence interval [CI], 0.13-7.3) and correlated with patient height (0.27 mm/cm; 95% CI, 0.11-0.43) and body surface area (BSA, 16 mm/m 2 ; 95% CI, 8.3-24) and inversely with body mass index (BMI, -0.40 mm/kg m -2 ; 95% CI, -0.75 to -0.054) in a wall stress-dependent manner. Wall stress-adjusted RRED neutral was raised if the patient was currently smoking (1.1 mm; 95% CI, 0.21-1.9). Age, MAP, family history, and patient weight were unrelated to RRED neutral . In specific FEA, RRED specific increased with female gender, MAP, family history positive for AAA, height, and BSA, whereas it was inversely related to BMI. All results were independent of aneurysm diameter. Peak wall stress and RRED correlated with aneurysm diameter and lumen volume. Female gender, current smoking, increased patient height and BSA, and low BMI were found to increase the mechanical rupture risk of AAAs. Previously described rupture risk factors may in part be explained by patient characteristic-dependent variations in aneurysm biomechanics. Copyright © 2016 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  9. Nonlifting wing-body combinations with certain geometric restraints having minimum wave drag at low supersonic speeds

    NASA Technical Reports Server (NTRS)

    Lomax, Harvard

    1957-01-01

    Several variational problems involving optimum wing and body combinations having minimum wave drag for different kinds of geometrical restraints are analyzed. Particular attention is paid to the effect on the wave drag of shortening the fuselage and, for slender axially symmetric bodies, the effect of fixing the fuselage diameter at several points or even of fixing whole portions of its shape.

  10. Computer simulations of comet- and asteroidlike bodies passing through the Venusian atmosphere: Preliminary results on atmospheric and ground shock effects

    NASA Technical Reports Server (NTRS)

    Roddy, D.; Hatfield, D.; Hassig, P.; Rosenblatt, M.; Soderblom, L.; Dejong, E.

    1992-01-01

    We have completed computer simulations that model shock effects in the venusian atmosphere caused during the passage of two cometlike bodies 100 m and 1000 m in diameter and an asteroidlike body 10 km in diameter. Our objective is to examine hypervelocity-generated shock effects in the venusian atmosphere for bodies of different types and sizes in order to understand the following: (1) their deceleration and depth of penetration through the atmosphere; and (2) the onset of possible ground-surface shock effects such as splotches, craters, and ejecta formations. The three bodies were chosen to include both a range of general conditions applicable to Venus as well as three specific cases of current interest. These calculations use a new multiphase computer code (DICE-MAZ) designed by California Research & Technology for shock-dynamics simulations in complex environments. The code was tested and calibrated in large-scale explosion, cratering, and ejecta research. It treats a wide range of different multiphase conditions, including material types (vapor, melt, solid), particle-size distributions, and shock-induced dynamic changes in velocities, pressures, temperatures (internal energies), densities, and other related parameters, all of which were recorded in our calculations.

  11. System for producing a uniform rubble bed for in situ processes

    DOEpatents

    Galloway, Terry R.

    1983-01-01

    A method and a cutter for producing a large cavity filled with a uniform bed of rubblized oil shale or other material, for in situ processing. A raise drill head (72) has a hollow body (76) with a generally circular base and sloping upper surface. A hollow shaft (74) extends from the hollow body (76). Cutter teeth (78) are mounted on the upper surface of the body (76) and relatively small holes (77) are formed in the body (76) between the cutter teeth (78). Relatively large peripheral flutes (80) around the body (76) allow material to drop below the drill head (72). A pilot hole is drilled into the oil shale deposit. The pilot hole is reamed into a large diameter hole by means of a large diameter raise drill head or cutter to produce a cavity filled with rubble. A flushing fluid, such as air, is circulated through the pilot hole during the reaming operation to remove fines through the raise drill, thereby removing sufficient material to create sufficient void space, and allowing the larger particles to fill the cavity and provide a uniform bed of rubblized oil shale.

  12. Body size limits dim-light foraging activity in stingless bees (Apidae: Meliponini).

    PubMed

    Streinzer, Martin; Huber, Werner; Spaethe, Johannes

    2016-10-01

    Stingless bees constitute a species-rich tribe of tropical and subtropical eusocial Apidae that act as important pollinators for flowering plants. Many foraging tasks rely on vision, e.g. spatial orientation and detection of food sources and nest entrances. Meliponini workers are usually small, which sets limits on eye morphology and thus quality of vision. Limitations are expected both on acuity, and thus on the ability to detect objects from a distance, as well as on sensitivity, and thus on the foraging time window at dusk and dawn. In this study, we determined light intensity thresholds for flight under dim light conditions in eight stingless bee species in relation to body size in a Neotropical lowland rainforest. Species varied in body size (0.8-1.7 mm thorax-width), and we found a strong negative correlation with light intensity thresholds (0.1-79 lx). Further, we measured eye size, ocelli diameter, ommatidia number, and facet diameter. All parameters significantly correlated with body size. A disproportionately low light intensity threshold in the minute Trigonisca pipioli, together with a large eye parameter P eye suggests specific adaptations to circumvent the optical constraints imposed by the small body size. We discuss the implications of body size in bees on foraging behavior.

  13. Laser circular cutting of Kevlar sheets: Analysis of thermal stress filed and assessment of cutting geometry

    NASA Astrophysics Data System (ADS)

    Yilbas, B. S.; Akhtar, S. S.; Karatas, C.

    2017-11-01

    A Kevlar laminate has negative thermal expansion coefficient, which makes it difficult to machine at room temperaures using the conventional cutting tools. Contararily, laser machining of a Kevlar laminate provides advantages over the conventional methods because of the non-mechanical contact between the cutting tool and the workpiece. In the present study, laser circular cutting of Kevlar laminate is considered. The experiment is carried out to examine and evaluate the cutting sections. Temperature and stress fields formed in the cutting section are simulated in line with the experimental study. The influence of hole diameters on temperature and stress fields are investigated incorporating two different hole diameters. It is found that the Kevlar laminate cutting section is free from large size asperities such as large scale sideways burnings and attachemnt of charred residues. The maximum temperature along the cutting circumference remains higher for the large diameter hole than that of the small diameter hole. Temperature decay is sharp around the cutting section in the region where the cutting terminates. This, in turn, results in high temperature gradients and the thermal strain in the cutting region. von Mises stress remains high in the region where temperature gradients are high. von Mises stress follows similar to the trend of temperature decay around the cutting edges.

  14. Comparison of radiographic and computed tomographic measurement of pedicle and vertebral body dimensions in Koreans: the ratio of pedicle transverse diameter to vertebral body transverse diameter.

    PubMed

    Kang, Ki Ser; Song, Kwang-Sup; Lee, Jong Seok; Yang, Jae Jun; Song, In Sup

    2011-03-01

    This study was designed to investigate the characteristics of pedicle transverse diameters (PD), vertebral body transverse diameters (VBD), especially the ratios of PD/VBD (CT ratio), which has never been discussed, in Koreans using computed tomography (CT) scans and to evaluate the possibility of obtaining more accurate estimations of PD from plain radiographs using the CT ratios in each spine level. The T1-L5 vertebrae of 50 participants were analyzed prospectively with CT scans (CT-VBD and CT-PD), and the T9-L5 vertebrae of the same participants were investigated with plain radiographs (X-VBD and X-PD). The CT ratio had a higher correlation with the CT-PD (r2 = 0.630) from T1 to L5, especially in the lower thoracic and lumbar spine (T9-L5, r2 = 0.737). The correlation of VBDs between the two radiologic tools (r2 = 0.896) was higher than that of the PDs (r2 = 0.665). Based on the data, equations for the estimation of a more accurate PD from plain radiographs were developed as follows: estimated PD = estimated VBD × [1.014 × (X-VBD) + 0.152] × the mean CT ratio at each spinal level. The correlation between the estimated PD and the CT-PD (r2 = 0.852) was improved compared with that (r2 = 0.665) between the X-PD and the CT-PD. In conclusion, the CT ratio showed a very similar changing trends to CT-PD from T1 to L5 regardless of sex and body mass, and the measurement error of PD from only plain radiographs could be minimized using estimated VBD and the mean CT ratio at each spinal level.

  15. Can the Yarkovsky effect significantly influence the main-belt size distribution?

    NASA Astrophysics Data System (ADS)

    O'Brien, D. P.; Greenberg, R.

    2001-11-01

    It has been proposed that the size distribution of main-belt asteroids may be significantly modified by the Yarkovsky effect---a size-dependent radiation force which can sweep asteroids into resonances and out of the main belt. Bell [1] suggested that this effect could deplete the population of asteroids smaller than ~10 m by at least an order of magnitude, resulting in the lack of small craters observed on Eros. Others have hypothesized that the same effect could explain the steepness of the crater distribution on Gaspra [2]. We have explicitly included Yarkovsky removal in a numerical collisional evolution model. The algorithm uses recent calculations of the expected removal rates of different sized bodies from the main belt (David Vokrouhlicky, personal communication). We find that the rate of removal of bodies from the main belt by the Yarkovsky effect may be within an order of magnitude of the rate of collisional destruction for asteroids ~10 m in diameter, and negligible for larger or smaller asteroids. When Yarkovsky removal is incorporated into our numerical collisional evolution model, the numbers of bodies ~10 m in diameter is reduced by ~10-20%, and a wave propagates up the size distribution increasing the number of bodies ~300 m by ~10%. This `waviness' could conceivably be detected in the cratering records on asteroids. However, the uncertainties in crater counts on Ida, Gaspra, Malthide, and Eros are >10% for diameters >100 m (i. e. the craters made by impactors >10 m in diameter). Contrary to the earlier hypothesis, Yarkovsky removal of small asteroids cannot have substantially affected the overall slopes of the crater populations on these asteroids. Moreover, Yarkovsky removal cannot explain the lack of small (<10 m) craters on Eros, because the corresponding impactors (<1 m) are unaffected by the Yarkovsky effect. [1] Bell, J. F. (2001). LPSC XXXII abstract no. 1964. [2] Hartmann, W. K. and E. V. Ryan (1996). DPS 28, abstract no. 10.35.

  16. Thermal cycler

    DOEpatents

    Benett, William J.; Andreski, John T.; Dzenitis, John M.; Makarewicz, Anthony J.; Hadley, Dean R.; Pannu, Satinderpall S.

    2014-07-15

    A thermalcycler includes a first thermalcycler body section having a first face and a second thermalcycler body section having a second face. A cavity is formed by the first face and the second face. A thermalcycling unit is positioned in the cavity. A heater trace unit is connected to a support section, to the first thermalcycler body section, to the second thermalcycler body section, and to the thermalcycling unit. The first thermalcycler body section and the second thermalcycler body section are positioned together against the support section to enclose the thermalcycling unit and the heater trace unit.

  17. Impact craters at falling of large asteroids in Ukraine

    NASA Astrophysics Data System (ADS)

    Vidmachenko, A. P.

    2016-05-01

    Catastrophes of different scale that are associated with the fall of celestial bodies to the Earth - occurred repeatedly in its history. But direct evidence of such catastrophes has been discovered recently. Thus, in the late 1970s studies of terrestrial rocks showed that in layers of the earth's crust that corresponded to the period of 65 million years before the present, marked by the mass extinction of some species of living creatures, and the beginning of the rapid development of others. It was then - a large body crashed to Earth in the Gulf of Mexico in Central America. The consequence of this is the Chicxulub crater with a diameter of ~170 km on Yucatan Peninsula. Modern Earth's surface retains many traces of collisions with large cosmic bodies. To indicate the craters with a diameter of more than 2 km using the name "astrobleme". Today, it found more than 230. The largest astroblems sizes exceeding 200 km. Ukraine also has some own astroblems. In Ukraine, been found nine large impact craters. Ukrainian crystalline shield, because of its stability for a long time (more than 1.5 billion years), has the highest density of large astroblems on the Earth's surface. The largest of the Ukrainian astroblems is Manevytska. It has a diameter of 45 km. There are also Ilyinetskyi (7 km), Boltysh (25 km), Obolon' (20 km), Ternivka (12-15 km), Bilylivskyi (6 km), Rotmystrivka (3 km) craters. Zelenohayska astrobleme founded near the village Zelenyi Gay in Kirovograd region and consists of two craters: larger with diameter 2.5-3.5 km and smaller - with diameter of 800 m. The presence of graphite, which was the basis for the research of the impact diamond in astroblems of this region. As a result, the diamonds have been found in rocks of Ilyinetskyi crater; later it have been found in rocks in the Bilylivska, Obolon' and other impact structures. The most detailed was studied the geological structure and the presence of diamonds in Bilylivska astrobleme

  18. Treatment influencing down-staging in EORTC Melanoma Group sentinel node histological protocol compared with complete step-sectioning: a national multicentre study.

    PubMed

    Riber-Hansen, Rikke; Hastrup, Nina; Clemmensen, Ole; Behrendt, Nille; Klausen, Siri; Ramsing, Mette; Spaun, Eva; Hamilton-Dutoit, Stephen Jacques; Steiniche, Torben

    2012-02-01

    Metastasis size in melanoma sentinel lymph nodes (SLNs) is an emerging prognostic factor. Two European melanoma treatment trials include SLN metastasis diameters as inclusion criteria. Whilst diameter estimates are sensitive to the number of sections examined, the level of this bias is largely unknown. We performed a prospective multicentre study to compare the European Organisation for Research and Treatment of Cancer (EORTC) recommended protocol with a protocol of complete step-sectioning. One hundred and thirty-three consecutive SLNs from seven SLN centres were analysed by five central sections 50μm apart (EORTC Protocol) followed by complete 250μm step-sectioning. Overall, 29 patients (21.8%) were SLN-positive. The EORTC Protocol missed eight of these metastases (28%), one metastasis measuring less than 0.1mm in diameter, seven measuring between 0.1 and 1mm. Complete step-sectioning at 250μm intervals (Extensive Protocol) missed one metastasis (3%) that measured less than 0.1mm. Thirteen treatment courses (34%) performed if inclusion was based on the Combined Protocol would not be performed if assessed by the EORTC Protocol. Thus, 10 patients would be without completion lymph node dissection (EORTC MINITUB study), whilst three patients would not be eligible for anti-CTLA4 trial (EORTC protocol 18071). The corresponding number with the Extensive Protocol would be three; one patient for the MINITUB registration study and two patients for the anti-CTLA4 study. Examining SLNs by close central sectioning alone (EORTC Protocol) misses a substantial number of metastases and underestimates the maximum metastasis diameter, leading to important changes in patient eligibility for various treatment protocols. Copyright © 2011 Elsevier Ltd. All rights reserved.

  19. Torso geometry reconstruction and body surface electrode localization using three-dimensional photography.

    PubMed

    Perez-Alday, Erick A; Thomas, Jason A; Kabir, Muammar; Sedaghat, Golriz; Rogovoy, Nichole; van Dam, Eelco; van Dam, Peter; Woodward, William; Fuss, Cristina; Ferencik, Maros; Tereshchenko, Larisa G

    We conducted a prospective clinical study (n=14; 29% female) to assess the accuracy of a three-dimensional (3D) photography-based method of torso geometry reconstruction and body surface electrodes localization. The position of 74 body surface electrocardiographic (ECG) electrodes (diameter 5mm) was defined by two methods: 3D photography, and CT (marker diameter 2mm) or MRI (marker size 10×20mm) imaging. Bland-Altman analysis showed good agreement in X (bias -2.5 [95% limits of agreement (LoA) -19.5 to 14.3] mm), Y (bias -0.1 [95% LoA -14.1 to 13.9] mm), and Z coordinates (bias -0.8 [95% LoA -15.6 to 14.2] mm), as defined by the CT/MRI imaging, and 3D photography. The average Hausdorff distance between the two torso geometry reconstructions was 11.17±3.05mm. Thus, accurate torso geometry reconstruction using 3D photography is feasible. Body surface ECG electrodes coordinates as defined by the CT/MRI imaging, and 3D photography, are in good agreement. Copyright © 2017 Elsevier Inc. All rights reserved.

  20. Cross-section Trichometry: A Clinical Tool for Assessing the Progression and Treatment Response of Alopecia

    PubMed Central

    Wikramanayake, Tongyu Cao; Mauro, Lucia M; Tabas, Irene A; Chen, Anne L; Llanes, Isabel C; Jimenez, Joaquin J

    2012-01-01

    Background: To properly assess the progression and treatment response of alopecia, one must measure the changes in hair mass, which is influenced by both the density and diameter of hair. Unfortunately, a convenient device for hair mass evaluation had not been available to dermatologists until the recent introduction of the cross-section trichometer, which directly measures the cross-sectional area of an isolated bundle of hair. Objective: We sought to evaluate the accuracy and sensitivity of the HairCheck® device, a commercial product derived from the original cross-section trichometer. Materials and Methods: Bundles of surgical silk and human hair were used to evaluate the ability of the HairCheck® device to detect and measure small changes in the number and diameter of strands, and bundle weight. Results: Strong correlations were observed between the bundle's cross-sectional area, displayed as the numeric Hair Mass Index (HMI), the number of strands, the silk/hair diameter, and the bundle dry weight. Conclusion: HMI strongly correlated with the number and diameter of silk/hair, and the weight of the bundle, suggesting that it can serve as a valid indicator of hair mass. We have given the name cross-section trichometry (CST) to the methodology of obtaining the HMI using the HairCheck® system. CST is a simple modality for the quantification of hair mass, and may be used as a convenient and useful tool to clinically assess changes in hair mass caused by thinning, shedding, breakage, or growth in males and females with progressive alopecia or those receiving alopecia treatment. PMID:23766610

  1. MM&T for Linear Resonant Cooler. Volume 1

    DTIC Science & Technology

    1988-02-16

    Tesla *Magnet Material Samarium Cobalt Radially Magnetized Inner Diameter = 1.25" Length = 0.79" Coil Assembly Number of Turns/Section = 90 Outside...Diameter = 1.22" Inside Diameter = 0.86" Inner Iron Material 2 V Permendur Inside Diameter = 0.38" Length 1.84" Design Max. Flux Density = 2.4 Tesla 0 3-12...suspended with rubber bands 60 inches above the floor of the semi -anechoic room. A six foot square piece of 2 inch thick foam was centered on the floor

  2. Thermoregulation of fish and turtles in thermally stressed habitats. Annual progress report, October 1, 1977--September 30, 1978

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Spotila, J.R.

    1978-06-01

    Morphometric and heating and cooling studies on over 100 largemouth bass, Micropterus salmoides, have provided the data needed to refine the time-dependent body temperature model for fish. The model can now track the changes in body temperature of a bass if its weight and water temperature are known. The model is most sensitive to body diameter, body wall thickness, and tissue conductivity. Doubling tissue conductivity is equivalent to decreasing body diameter by a factor or two. Turtles, Chrysemys scripta, living in the heated portion of a cooling reservoir facultatively exploit the warmed water (..delta..T = 4 to 10/sup 0/C) asmore » an auxiliary heat source for behavioral thermoregulation. Turtles in the heated arm of PAR pond have a smaller home range (200 m) than turtles in an ambient portion of the reservoir (507 m). The ability of animals to thermoregulate at a high constant body temperature depends upon the constraints imposed on them by their body size and physical characteristics and those of their environment. The net heat production required to maintain a specific body temperature changes as the size of an ectotherm increases. Operative environmental temperature is an appropriate measure of environmental heat loading and can be used as a predictor of turtle behavior. This concept may become very valuable in quantifying the effect of thermal effluents on turtle and fish behavior.« less

  3. Impact cratering on porous targets in the strength regime

    NASA Astrophysics Data System (ADS)

    Nakamura, Akiko M.

    2017-12-01

    Cratering on small bodies is crucial for the collision cascade and also contributes to the ejection of dust particles into interplanetary space. A crater cavity forms against the mechanical strength of the surface, gravitational acceleration, or both. The formation of moderately sized craters that are sufficiently larger than the thickness of the regolith on small bodies, in which mechanical strength plays the dominant role rather than gravitational acceleration, is in the strength regime. The formation of microcraters on blocks on the surface is also within the strength regime. On the other hand, the formation of a crater of a size comparable to the thickness of the regolith is affected by both gravitational acceleration and cohesion between regolith particles. In this short review, we compile data from the literature pertaining to impact cratering experiments on porous targets, and summarize the ratio of spall diameter to pit diameter, the depth, diameter, and volume of the crater cavity, and the ratio of depth to diameter. Among targets with various porosities studied in the laboratory to date, based on conventional scaling laws (Holsapple and Schmidt, J. Geophys. Res., 87, 1849-1870, 1982) the cratering efficiency obtained for porous sedimentary rocks (Suzuki et al., J. Geophys. Res. 117, E08012, 2012) is intermediate. A comparison with microcraters formed on a glass target with impact velocities up to 14 km s-1 indicates a different dependence of cratering efficiency and depth-to-diameter ratio on impact velocity.

  4. Comparison of the effects of letrozole and cabergoline on vascular permeability, ovarian diameter, ovarian tissue VEGF levels, and blood PEDF levels, in a rat model of ovarian hyperstimulation syndrome.

    PubMed

    Şahin, Nur; Apaydın, Nesin; Töz, Emrah; Sivrikoz, Oya Nermin; Genç, Mine; Turan, Gülüzar Arzu; Cengiz, Hakan; Eskicioğlu, Fatma

    2016-05-01

    To evaluate the effects of letrozole and cabergoline in a rat model of ovarian hyperstimulation syndrome (OHSS). In this prospective, controlled experimental study, the 28 female Wistar rats were divided into four subgroups (one non-stimulated control and three OHSS-positive groups: placebo, letrozole, and cabergoline). To induce OHSS, rats were injected with 10 IU of pregnant mare serum gonadotropin from day 29 to day 32 of life, followed by subcutaneous injection of 30 IU hCG on day 33. Letrozole rats received with a single dose of 0.1 mg/kg letrozole via oral gavage, on the hCG day. Cabergoline rats received with a single dose of 100 µg/kg cabergoline via oral gavage, on the hCG day. All animals were compared in terms of body weight, vascular permeability (VP), ovarian diameter, ovarian tissue VEGF expression (assessed via immunohistochemical staining), and blood pigment epithelium-derived growth factor (PEDF) levels. The OHSS-positive placebo group (group 2) exhibited the highest VP, ovarian diameter, extent of VEGF staining, and lowest PEDF level, as expected. No significant difference was evident between the letrozole and cabergoline groups in terms of any of body weight; VP; PEDF level; ovarian diameter; or the staining intensity of, or percentage staining for, VEGF in ovarian tissues. Letrozole and cabergoline were equally effective to prevent OHSS, reducing the ovarian diameter, VP, and PEDF and VEGF levels to similar extents.

  5. Early signs that predict later haemodynamically significant patent ductus arteriosus.

    PubMed

    Engür, Defne; Deveci, Murat; Türkmen, Münevver K

    2016-03-01

    Our aim was to determine the optimal cut-off values, sensitivity, specificity, and diagnostic power of 12 echocardiographic parameters on the second day of life to predict subsequent ductal patency. We evaluated preterm infants, born at ⩽32 weeks of gestation, starting on their second day of life, and they were evaluated every other day until ductal closure or until there were clinical signs of re-opening. We measured transductal diameter; pulmonary arterial diastolic flow; retrograde aortic diastolic flow; pulsatility index of the left pulmonary artery and descending aorta; left atrium and ventricle/aortic root ratio; left ventricular output; left ventricular flow velocity time integral; mitral early/late diastolic flow; and superior caval vein diameter and flow as well as performed receiver operating curve analysis. Transductal diameter (>1.5 mm); pulmonary arterial diastolic flow (>25.6 cm/second); presence of retrograde aortic diastolic flow; ductal diameter by body weight (>1.07 mm/kg); left pulmonary arterial pulsatility index (⩽0.71); and left ventricle to aortic root ratio (>2.2) displayed high sensitivity and specificity (p0.9). Parameters with moderate sensitivity and specificity were as follows: left atrial to aortic root ratio; left ventricular output; left ventricular flow velocity time integral; and mitral early/late diastolic flow ratio (p0.05) had low diagnostic value. Left pulmonary arterial pulsatility index, left ventricle/aortic root ratio, and ductal diameter by body weight are useful adjuncts offering a broader outlook for predicting ductal patency.

  6. 33 CFR 84.11 - Shapes.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... diameter of not less than 0.6 meter and a height equal to its diameter; (3) A diamond shape shall consist of two cones (as defined in paragraph (a)(2) of this section) having a common base. (b) The vertical...

  7. 33 CFR 84.11 - Shapes.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... diameter of not less than 0.6 meter and a height equal to its diameter; (3) A diamond shape shall consist of two cones (as defined in paragraph (a)(2) of this section) having a common base. (b) The vertical...

  8. 33 CFR 84.11 - Shapes.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... diameter of not less than 0.6 meter and a height equal to its diameter; (3) A diamond shape shall consist of two cones (as defined in paragraph (a)(2) of this section) having a common base. (b) The vertical...

  9. 33 CFR 84.11 - Shapes.

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... diameter of not less than 0.6 meter and a height equal to its diameter; (3) A diamond shape shall consist of two cones (as defined in paragraph (a)(2) of this section) having a common base. (b) The vertical...

  10. 33 CFR 84.11 - Shapes.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... diameter of not less than 0.6 meter and a height equal to its diameter; (3) A diamond shape shall consist of two cones (as defined in paragraph (a)(2) of this section) having a common base. (b) The vertical...

  11. Repair Types, Procedures - Part 2

    DTIC Science & Technology

    2010-05-01

    completely severed or severely damaged fuel lines, cut away the damaged section and use a piece of fuel- resistant rubber hose with an inner diameter...equal to the existing fuel line outer diameter to replace the damaged section. Ensure the repair hose extends far enough on each side of the damage to...accommodate two hose clamps, oriented 180° from one another. Flare the ends of the existing fuel line to improve the seal and prevent leakage

  12. Pressurized water nuclear reactor system with hot leg vortex mitigator

    DOEpatents

    Lau, Louis K. S.

    1990-01-01

    A pressurized water nuclear reactor system includes a vortex mitigator in the form of a cylindrical conduit between the hot leg conduit and a first section of residual heat removal conduit, which conduit leads to a pump and a second section of residual heat removal conduit leading back to the reactor pressure vessel. The cylindrical conduit is of such a size that where the hot leg has an inner diameter D.sub.1, the first section has an inner diameter D.sub.2, and the cylindrical conduit or step nozzle has a length L and an inner diameter of D.sub.3 ; D.sub.3 /D.sub.1 is at least 0.55, D.sub.2 is at least 1.9, and L/D.sub.3 is at least 1.44, whereby cavitation of the pump by a vortex formed in the hot leg is prevented.

  13. Association of height, body weight, age, and corneal diameter with calculated intraocular lens strength of adult horses.

    PubMed

    Mouney, Meredith C; Townsend, Wendy M; Moore, George E

    2012-12-01

    To determine whether differences exist in the calculated intraocular lens (IOL) strengths of a population of adult horses and to assess the association between calculated IOL strength and horse height, body weight, and age, and between calculated IOL strength and corneal diameter. 28 clinically normal adult horses (56 eyes). Axial globe lengths and anterior chamber depths were measured ultrasonographically. Corneal curvatures were determined with a modified photokeratometer and brightness-mode ultrasonographic images. Data were used in the Binkhorst equation to calculate the predicted IOL strength for each eye. The calculated IOL strengths were compared with a repeated-measures ANOVA. Corneal curvature values (photokeratometer vs brightness-mode ultrasonographic images) were compared with a paired t test. Coefficients of determination were used to measure associations. Calculated IOL strengths (range, 15.4 to 30.1 diopters) differed significantly among horses. There was a significant difference in the corneal curvatures as determined via the 2 methods. Weak associations were found between calculated IOL strength and horse height and between calculated IOL strength and vertical corneal diameter. Calculated IOL strength differed significantly among horses. Because only weak associations were detected between calculated IOL strength and horse height and vertical corneal diameter, these factors would not serve as reliable indicators for selection of the IOL strength for a specific horse.

  14. Description of a new species of the genus Mongolotettix Rehn, 1928 (Orthoptera: Acrididae) from Fujian, China.

    PubMed

    Chen, Shen-Zhi; Shi, Jian-Ping; Dai, Li

    2018-04-17

    A new species of the genus Mongolotettix Rehn, 1928 from Fujian, China is described in this paper. The new species Mongolotettix.fujianensis sp. nov. is similar to M. wulingyuanensis Shi, Liu et Li, 2016, but differs from the latter by maximum width of cubital area 1.4 times maximum width of medial area in tegmina of male; body small, length of body ♂ 21.5. mm, ♀ 30.6 mm; vertical diameter eye 1.3 times horizontal diameter in male; hind femur of male with 103 stridulatory pegs on inner side and epiphallus with indistinct projection on inner side of lateral plates. Type specimens are deposited in the Shanghai Entomological Museum, Chinese Academy of Sciences, Shanghai, 200032, China.

  15. Genetic analysis of QTL for eye cross and eye diameter in common carp (Cyprinus carpio L.) using microsatellites and SNPs.

    PubMed

    Jin, S B; Zhang, X F; Lu, J G; Fu, H T; Jia, Z Y; Sun, X W

    2015-04-17

    A group of 107 F1 hybrid common carp was used to construct a linkage map using JoinMap 4.0. A total of 4877 microsatellite and single nucleotide polymorphism (SNP) markers isolated from a genomic library (978 microsatellite and 3899 SNP markers) were assigned to construct the genetic map, which comprised 50 linkage groups. The total length of the linkage map for the common carp was 4775.90 cM with an average distance between markers of 0.98 cM. Ten quantitative trait loci (QTL) were associated with eye diameter, corresponding to 10.5-57.2% of the total phenotypic variation. Twenty QTL were related to eye cross, contributing to 10.8-36.9% of the total phenotypic variation. Two QTL for eye diameter and four QTL for eye cross each accounted for more than 20% of the total phenotypic variation and were considered to be major QTL. One growth factor related to eye diameter was observed on LG10 of the common carp genome, and three growth factors related to eye cross were observed on LG10, LG35, and LG44 of the common carp genome. The significant positive relationship of eye cross and eye diameter with other commercial traits suggests that eye diameter and eye cross can be used to assist in indirect selection for many commercial traits, particularly body weight. Thus, the growth factor for eye cross may also contribute to the growth of body weight, implying that aggregate breeding could have multiple effects. These findings provide information for future genetic studies and breeding of common carp.

  16. Experimental investigation of two-phase flow patterns in minichannels at horizontal orientation

    NASA Astrophysics Data System (ADS)

    Saljoshi, P. S.; Autee, A. T.

    2017-09-01

    Two-phase flow is the simplest case of multiphase flow in which two phases are present for a pure component. The mini channel is considered as diameter below 3.0-0.2 mm and conventional channel is considered diameter above 3.0 mm. An experiment was conducted to study the adiabatic two-phase flow patterns in the circular test section with inner diameter of 1.1, 1.63, 2.0, 2.43 and 3.0 mm for horizontal orientation using air and water as a fluid. Different types of flow patterns found in the experiment. The parameters that affect most of these patterns and their transitions are channel size, phase superficial velocities (air and liquid) and surface tension. The superficial velocity of liquid and gas ranges from 0.01 to 66.70 and 0.01 to 3 m/s respectively. Two-phase flow pattern photos were recorded using a high speed CMOS camera. In this experiment different flow patterns were identified for different tube diameters that confirm the diameter effect on flow patterns in two-phase flows. Stratified flow was not observed for tube diameters less than 3.0 mm. Similarly, wavy-annular flow pattern was not observed in 1.6 and 1.0 mm diameter tubes due to the surface-tension effect and decrease in tube diameter. Buoyancy effects were clearly visible in 2.43 and 3.0 mm diameter tubes flow pattern. It has also observed that as the test-section diameter decreases the transition lines shift towards the higher gas and liquid velocity. However, the result of flow pattern lines in the present study has good agreement with the some of the existing flow patterns maps.

  17. Estimation of Tree Position and STEM Diameter Using Simultaneous Localization and Mapping with Data from a Backpack-Mounted Laser Scanner

    NASA Astrophysics Data System (ADS)

    Holmgren, J.; Tulldahl, H. M.; Nordlöf, J.; Nyström, M.; Olofsson, K.; Rydell, J.; Willén, E.

    2017-10-01

    A system was developed for automatic estimations of tree positions and stem diameters. The sensor trajectory was first estimated using a positioning system that consists of a low precision inertial measurement unit supported by image matching with data from a stereo-camera. The initial estimation of the sensor trajectory was then calibrated by adjustments of the sensor pose using the laser scanner data. Special features suitable for forest environments were used to solve the correspondence and matching problems. Tree stem diameters were estimated for stem sections using laser data from individual scanner rotations and were then used for calibration of the sensor pose. A segmentation algorithm was used to associate stem sections to individual tree stems. The stem diameter estimates of all stem sections associated to the same tree stem were then combined for estimation of stem diameter at breast height (DBH). The system was validated on four 20 m radius circular plots and manual measured trees were automatically linked to trees detected in laser data. The DBH could be estimated with a RMSE of 19 mm (6 %) and a bias of 8 mm (3 %). The calibrated sensor trajectory and the combined use of circle fits from individual scanner rotations made it possible to obtain reliable DBH estimates also with a low precision positioning system.

  18. Morphometric assessment of in vitro matured dromedary camel oocytes determines the developmental competence after parthenogenetic activation.

    PubMed

    Saadeldin, Islam M; Swelum, Ayman Abdel-Aziz; Yaqoob, Syed Hilal; Alowaimer, Abdullah Nasser

    2017-06-01

    The aim of the current study was to improve the selection method of camel oocytes after in vitro maturation by reducing exclusion criteria that were based only on the presence of the first polar body. A combined nuclear and morphometric assessment of camel oocytes after in vitro maturation was included to perform a judgment. The nuclear status of the oocytes, including the presence of the first polar body, meiosis I stage, and lack of nuclear materials, was investigated. The morphometric criteria that comprised the dimensions of each oocyte were as follows: diameter of the whole oocyte, including the zona pellucida (ZPO), zona pellucida thickness (ZPT), ooplasm diameter (OD), the perivitelline space (PVS) area, and PVS diameter. Among the oocytes with different nuclear status, there were no differences in ZPO and ZPT. However, oocytes with no nuclear material showed a significant reduction in OD (110.19 ± 1.4 μm) and a significant increase in PVS area (2139 ± 324.6 μm 2 ) and PVS diameter (13.9 ± 1.96 μm) when compared with oocytes in the meiosis I stage (117.41 ± 2.85 μm, 1287.4 ± 123.4 μm 2 , and 8.56 ± 0.65 μm, respectively). To simplify the selection, the major difference between meiosis I and degenerated oocytes was the diameter of the PVS, which was greater than the ZPT in degenerated oocytes. Therefore, three groups were morphologically differentiated into oocytes with polar bodies (PB1), meiosis I (MI) oocytes, and degenerated oocytes. MI oocytes were able to extrude the polar body after activation but were not able to develop into blastocysts. In contrast, MI oocytes were able to develop into blastocysts after a biphasic activation protocol in which the oocytes were electrically activated and treated with ionomycin after 2 h. In conclusion, the results obtained by the morphometric assessment allowed us to develop a simple and objective classification system for in vitro matured dromedary camel oocytes, which will lead to accurate oocyte selection for the support of subsequent embryonic development. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. Nanogrid rolling circle DNA sequencing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Church, George M.; Porreca, Gregory J.; Shendure, Jay

    The present invention relates to methods for sequencing a polynucleotide immobilized on an array having a plurality of specific regions each having a defined diameter size, including synthesizing a concatemer of a polynucleotide by rolling circle amplification, wherein the concatemer has a cross-sectional diameter greater than the diameter of a specific region, immobilizing the concatemer to the specific region to make an immobilized concatemer, and sequencing the immobilized concatemer.

  20. Globular bodies: a primary cause of the opacity in senile and diabetic posterior cortical subcapsular cataracts?

    PubMed

    Creighton, M O; Trevithick, J R; Mousa, G Y; Percy, D H; McKinna, A J; Dyson, C; Maisel, H; Bradley, R

    1978-07-01

    We examined 9 cataracts from maturity onset diabetics and 4 senile posterior subcapsular cataracts by scanning electron microscopy, transmission electron microscopy, immunofluorescence for crystallin proteins and actin, histochemical methods and x-ray diffraction. The cataractous regions contained spherical globules up to 20 mu in diameter, often in a fibrous matrix. Some were extracellular Morgagnian globules, apparently formed by blebbing from the cell surface; others appeared to have been formed intracellularly. The area of globular degeneration was usually 300 mu deep, but had deeper fusiform extensions. Morphological changes in the cell cytoplasm varied according to their depth in the cataract. Electron microscopy showed intracellular and extracellular globules, many of them were bounded by lipid bilayer membranes. Immunofluorescent staining showed that all the globules contained gamma-crystallin; some contained alpha- and beta-crystallins and actin. All the globules contained higher concentrations of cysteine or cystine than the surrounding lens tissue but they did not react to stains for carbohydrate or calcium. X-ray diffraction studies showed that crystalline calcium salts were absent. Globules and cavities averaged 45% of the total area in cross section. Assuming an area of cataract to be 300 micron thick and that globules 1 mu in diameter scattered, while 2--20 mu in diameter reflected light, we calculated that light passing through such a thickness would be reduced by 65%. Thus the globules could account for most of the opacity of the cataractous area. Presumably the fibrous degeneration of the cells causes enough light scattering to account for the remainder of the reduction. Cataract patients complain of decreased visual acuity, a golden halo around objects, and difficulties when driving while facing oncoming traffic at night. These probably result from light scattering. In our previous experiments, globular bodies containing gamma-crystallin were found in cells grown in tissue culture, and blebs with increased acitn content similar to Morgagnian globules were formed in tissue culture by treating differentiated rat lens cells of stage 2 by cytochalasin D (which impaired microfilament function). These results suggest the possibility of simulating in tissue culture the morphological alterations seen in the cataractous cell.

  1. Experimental investigation on the influence of boundary layer thickness on the base pressure and near-wake flow features of an axisymmetric blunt-based body

    NASA Astrophysics Data System (ADS)

    Mariotti, Alessandro; Buresti, Guido

    2013-11-01

    The influence of the thickness of the boundary layer developing over the surface of an axisymmetric bluff body upon its base pressure and near-wake flow is analyzed experimentally. The model, whose diameter-to-length ratio is d/ l = 0.175, has a forebody with an elliptical contour and a sharp-edged flat base; it is supported above a plate by means of a faired strut. The pressure distributions over the body lateral and base surfaces were obtained using numerous pressure taps, while the boundary layer profiles and the wake velocity field were measured through hot-wire anemometry. The tests were carried out at , at which the boundary layer over the lateral surface of the body becomes turbulent before reaching the base contour. Strips of emery cloth were wrapped in various positions around the body circumference in order to modify the thickness and the characteristics of the boundary layer. The results show that increasing the boundary layer thickness causes a decrease in the base suctions and a corresponding increase in the length of the mean recirculation region present behind the body. In the spectra of the velocity fluctuations measured within and aside the wake, a dominating peak becomes evident in the region downstream of the final part of the recirculation region. The relevant non-dimensional frequency decreases with increasing boundary layer thickness; however, a Strouhal number based on the wake width and the velocity defect at a suitable reference cross section downstream of the recirculation region is found to remain almost constant for the different cases.

  2. Measurement of cardiac dimensions with two-dimensional echocardiography in the living horse.

    PubMed

    Voros, K; Holmes, J R; Gibbs, C

    1991-11-01

    Two-dimensional echocardiography (2DE) was performed on 22 unsedated Thoroughbred and part Thoroughbred horses weighing between 411 and 650 kg to establish normal reference values for 2DE measurements. Animals stood during examinations performed with a 3.5 MHz mechanical sector transducer using various transducer positions and tomographic planes. Right ventricular diameter (RVD), ventricular septal thickness (VSTh), aortic diameter (AoD), area of the chordal lumen of the left ventricle (CTA), left ventricular diameter (LVD) and left atrial diameter (LAD) were determined at ventricular end-diastole (Ed) and/or end-systole (Es). Fractional shortening (FS) of the left ventricle and end-systolic left atrial to aortic ratio (LAD-Es:AoD-Es) also were calculated. Echocardiographic data were related to body weight by linear regression analysis. Intra-observer variability was checked in five horses by measuring each parameter during each of 10 consecutive cardiac cycles. The 2DE data were compared with M-mode values in published reports. In the 18 horses whose weight did not exceed 551 kg, repeatable recordings of good quality were obtained, and 2DE measurements could be made using intra-cardiac reference points. Increasing body weight proved to impose substantial limitations on measurements taken with the available machine and transducer. This problem might be overcome by using probes of lower frequency or equipment with higher quality image display at greater depth. The following parameters correlated significantly to body weight: VSTh-Es (r = 0.69; P less than 0.01). AoD-Es (r = 0.64; P less than 0.01) and CTA-Es (r = 0.84; P less than 0.001).(ABSTRACT TRUNCATED AT 250 WORDS)

  3. Reverse laser drilling

    NASA Technical Reports Server (NTRS)

    Anthony, Thomas R. (Inventor)

    1984-01-01

    This invention provides a method for laser drilling small diameter, closely-spaced, and accurately located holes in a body of material which is transparent or substantially transparent to the laser radiation employed whereby the holes are drilled through the thickness of the body from the surface opposite to that on which the laser beam impinges to the surface of laser beam impingement.

  4. Identification of morphological markers of sarcopenia at early stage of aging in skeletal muscle of mice.

    PubMed

    Sayed, Ramy K A; de Leonardis, Erika Chacin; Guerrero-Martínez, José A; Rahim, Ibtissem; Mokhtar, Doaa M; Saleh, Abdelmohaimen M; Abdalla, Kamal E H; Pozo, María J; Escames, Germaine; López, Luis C; Acuña-Castroviejo, Darío

    2016-10-01

    The gastrocnemius muscle (GM) of young (3months) and aged (12months) female wild-type C57/BL6 mice was examined by light and electron microscopy, looking for the presence of structural changes at early stage of the aging process. Morphometrical parameters including body and gastrocnemius weights, number and type of muscle fibers, cross section area (CSA), perimeter, and Feret's diameter of single muscle fiber, were measured. Moreover, lengths of the sarcomere, A-band, I-band, H-zone, and number and CSA of intermyofibrillar mitochondria (IFM), were also determined. The results provide evidence that 12month-old mice had significant changes on skeletal muscle structure, beginning with the reduction of gastrocnemius weight to body weight ratio, compatible with an early loss of skeletal muscle function and strength. Moreover, light microscopy revealed increased muscle fibers size, with a significant increase on their CSA, perimeter, and diameter of both type I and type II muscle fibers, and a reduction in the percentage of muscle area occupied by type II fibers. Enhanced connective tissue infiltrations, and the presence of centrally nucleated muscle fibers, were also found in aged mice. These changes may underlie an attempt to compensate the loss of muscle mass and muscle fibers number. Furthermore, electron microscopy discovered a significant age-dependent increase in the length of sarcomeres, I and H bands, and reduction on the overlapped actin/myosin length, supporting contractile force loss with age. Electron microscopy also showed an increased number and CSA of IFM with age, which may reveal more endurance at 12months of age. Together, mice at early stage of aging already show significant changes in gastrocnemius muscle morphology and ultrastructure that are suggestive of the onset of sarcopenia. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Effect of Free Stream Turbulence on Flow Past a Circular Cylinder at Low Reynolds Numbers

    NASA Astrophysics Data System (ADS)

    Kumar, Vinoth; Singh, Mrityunjay; Thangadurai, Murugan; Chatterjee, P. K.

    2018-01-01

    Circular cylinders experiencing different upstream flow conditions have been studied for low Reynolds numbers using hot-wire anemometry and smoke flow visualizations. The upstream condition of the cylinder in the test section is varied using a wire mesh placed at the entrance of the test section. The Reynolds number is varied by varying the diameter of the cylinder and the mean velocity in the test section. Smooth cylinders of diameter varying from 1.25 to 25 mm are used in the present study. A multi-channel hot-wire anemometry is used for measuring the fluctuating velocities in the test section and the wake behind the cylinder. The sectional views of the wake behind the cylinder are obtained using a 4 MP CCD camera, 200 mJ pulsed laser and a fog generator. The flow quality in the test section is examined using higher order turbulence statistics. The effect of free stream turbulence levels and their frequencies on wake structures and the shedding frequencies of circular cylinders are studied in detail. It has been observed that the alteration in wake structure and the shedding frequency depend strongly on the frequencies and the amplitudes of upstream disturbances besides the diameter of the circular cylinder.

  6. Retrograde lag screw placement in anterior acetabular column with regard to the anterior pelvic plane and midsagittal plane -- virtual mapping of 260 three-dimensional hemipelvises for quantitative anatomic analysis.

    PubMed

    Ochs, Bjoern Gunnar; Stuby, Fabian Maria; Ateschrang, Atesch; Stoeckle, Ulrich; Gonser, Christoph Emanuel

    2014-10-01

    Percutaneous screw placement can be used for minimally invasive treatment of none or minimally displaced fractures of the anterior column. The complex pelvic geometry can pose a major challenge even for experienced surgeons. The present study examined the preformed bone stock of the anterior column in 260 hemipelvises (130 male and 130 female). Screws were virtually implanted using iPlan(®) CMF (BrainLAB AG, Feldkirchen, Germany); the maximal implant length and the maximal implant diameter were assessed. The study showed, that 6.5mm can generally be used in men; in women however individual planning is essential in regard to the maximal implant diameter since we found that in 15.4% of women, screws with a diameter less than 6.5mm were necessary. The virtual analysis of the preformed bone stock corridor of the anterior column showed two constrictions of crucial clinical importance. These can be found after 18% and 55% (men) respectively 16% and 55% (women) measured from the entry point along the axis of the implant. The entry point of the retrograde anterior column screw in our collective was located lateral of tuberculum pubicum at the level of the superior-medial margin of foramen obturatum. In female patients, the entry point was located significantly more lateral of symphysis and closer to the cranial margin of ramus superior ossis pubis. The mean angle between the screw trajectory and the anterior pelvic plane in sagittal section was 31.6 ± 5.5°, the mean angle between the screw trajectory and the midsagittal plane in axial section was 55.9 ± 4.6° and the mean angle between the screw trajectory and the midsagittal plane in coronal section was 42.1 ± 3.9° with no significant deviation between both sexes. The individual angles formed by the screw trajectory and the anterior pelvic and midsagittal plane are independent from anthropometric parameters sex, age, body length and weight. Therefore, they can be used for orientation in lag screw placement keeping in mind that the entry point differs in both sexes. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Design of Tools for Press-countersinking or Dimpling 0.040-inch-thick-24S-T Sheet

    NASA Technical Reports Server (NTRS)

    Templin, R L; Fogwell, J W

    1942-01-01

    A set of dimpling tools was designed for 0.040-inch 24S-T sheet and flush-type rivets 1/8 inch in diameter with 100 degree countersunk heads. The dimples produced under different conditions of pressure, sheet thickness, and drill diameter are presented as cross-sectional photographs magnified 20 times. The most satisfactory values for the dimpling tools were found to be: maximum punch diameter, 0.231 inch; maximum die diameter, 0.223 inch; maximum mandrel diameter, 0.128 inch; dimple angle, 100 degree; punch springback angle, 1 1/2 degree; and die springback angle, 2 degree.

  8. Relations among Adiposity and Insulin Resistance with Flow-Mediated Dilation, Carotid Intima-Media Thickness, and Arterial Stiffness in Children.

    PubMed

    Ryder, Justin R; Dengel, Donald R; Jacobs, David R; Sinaiko, Alan R; Kelly, Aaron S; Steinberger, Julia

    2016-01-01

    To determine the associations of adiposity and insulin resistance with measures of vascular structure and function in children. A cross-sectional study included 252 children (age 15.1 ± 2.4 years; body mass index percentile 68.2 ± 26.5%; Tanner 2-5). Measurements of body fat percentage were obtained with dual-energy X-ray absorptiometry and visceral adipose tissue (VAT) with computed tomography. Insulin resistance was measured with hyperinsulinemic euglycemic clamp. Vascular measurements for endothelial function (brachial artery flow-mediated dilation [FMD]), vascular structure (carotid intima-media thickness [cIMT]), vascular stiffness (carotid incremental elastic modulus), and pulse wave velocity were analyzed by tertiles of adiposity and insulin resistance. Additional analyses with ANCOVA and linear regression were adjusted for Tanner, sex, race, and family relationship; FMD was also adjusted for baseline artery diameter. FMD was positively associated with high adiposity (body mass index, body fat percentage, and VAT) (P < .01 all). Insulin resistance was not associated with FMD. cIMT was significantly, positively related to obesity, VAT, and insulin resistance (P < .05 all). No differences in carotid incremental elastic modulus and pulse wave velocity were observed in relation to adiposity or insulin resistance. The findings suggest that adiposity is associated with higher FMD, and insulin resistance and VAT are associated with higher cIMT in children. Further research is needed to clarify the progression of these relations. Copyright © 2016 Elsevier Inc. All rights reserved.

  9. Design and development of a large diameter high pressure fast acting propulsion valve and valve actuator

    NASA Technical Reports Server (NTRS)

    Srinivasan, K. V.

    1986-01-01

    The design and development of a large diameter high pressure quick acting propulsion valve and valve actuator is described. The valve is the heart of a major test facility dedicated to conducting full scale performance tests of aircraft landing systems. The valve opens in less than 300 milliseconds releasing a 46-centimeter- (18-in.-) diameter water jet and closes in 300 milliseconds. The four main components of the valve, i.e., valve body, safety shutter, high speed shutter, and pneumatic-hydraulic actuator, are discussed. This valve is unique and may have other aerospace and industrial applications.

  10. Design and Development of a Large Diameter, High Pressure, Fast Acting Propulsion Valve and Valve Actuator

    NASA Technical Reports Server (NTRS)

    Srinivasan, K. V.

    1986-01-01

    This paper describes the design and development of a large diameter high pressure quick acting propulsion valve and valve actuator. The valve is the heart of a major test facility dedicated to conducting full scale performance tests of aircraft landing gear systems. The valve opens in less than 300 milliseconds releasing a 46 cm (18 in) diameter water jet and closes in 300 milliseconds. The four main components of the valve, i.e., valve body, safety shutter, high speed shutter, and pneumatic-hydraulic actuator, are discussed. This valve is unique and may have other aerospace and industrial applications.

  11. 7 CFR 51.1537 - Diameter.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Diameter. 51.1537 Section 51.1537 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  12. 7 CFR 51.1537 - Diameter.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Diameter. 51.1537 Section 51.1537 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  13. 7 CFR 51.3211 - Diameter.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Diameter. 51.3211 Section 51.3211 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  14. 7 CFR 51.1537 - Diameter.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Diameter. 51.1537 Section 51.1537 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  15. 7 CFR 51.3211 - Diameter.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 7 Agriculture 2 2012-01-01 2012-01-01 false Diameter. 51.3211 Section 51.3211 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  16. 7 CFR 51.1537 - Diameter.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Diameter. 51.1537 Section 51.1537 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  17. 7 CFR 51.1537 - Diameter.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Diameter. 51.1537 Section 51.1537 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  18. 7 CFR 51.3211 - Diameter.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 7 Agriculture 2 2014-01-01 2014-01-01 false Diameter. 51.3211 Section 51.3211 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  19. 7 CFR 51.3211 - Diameter.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 7 Agriculture 2 2013-01-01 2013-01-01 false Diameter. 51.3211 Section 51.3211 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  20. 7 CFR 51.3211 - Diameter.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 7 Agriculture 2 2011-01-01 2011-01-01 false Diameter. 51.3211 Section 51.3211 Agriculture Regulations of the Department of Agriculture AGRICULTURAL MARKETING SERVICE (Standards, Inspections, Marketing Practices), DEPARTMENT OF AGRICULTURE REGULATIONS AND STANDARDS UNDER THE AGRICULTURAL MARKETING ACT OF 1946...

  1. Experimental study of surface pressures induced on a flat plate and a body of revolution by various dual jet configurations. [wind tunnel tudies of a jet in a cross flow for V/STOL applications

    NASA Technical Reports Server (NTRS)

    Schetz, J. A.; Jakubowski, A. K.

    1982-01-01

    The effect of the angle of a jet to a crossflow, the performance of dual jet configurations, and a jet injected from a body of revolution as opposed to a flat plate were investigated during experiments conducted in the 7x10 tunnel at NASA Ames at Velocities from 14.5 m/sec to 35.8 m/sec (47.6 to 117.4 ft/sec.). Pressure distributions are presented for single and dual jets over a range of velocity ratios from 2 to 10, spacings from 2 to 6 diameters and injection angles of 90, 75, 60, and 105 degrees. For the body of revolution tests, the ratio of the jet to body diameters was set as large (1/2) in order to be more representative of V/STOL aircraft applications. Flat plate tests involved dual jets both aligned and in side by side configurations. The effects of the various parameters and the differences between the axisymmetric and planar body geometrics on the nature, size, shape, and strength of the interaction regions on the body surfaces are shown. Some flowfield measurements are also presented, and it is shown that a simple analysis is capable of predicting the trajectories of the jets.

  2. Colony-Level Differences in the Scaling Rules Governing Wood Ant Compound Eye Structure.

    PubMed

    Perl, Craig D; Niven, Jeremy E

    2016-04-12

    Differential organ growth during development is essential for adults to maintain the correct proportions and achieve their characteristic shape. Organs scale with body size, a process known as allometry that has been studied extensively in a range of organisms. Such scaling rules, typically studied from a limited sample, are assumed to apply to all members of a population and/or species. Here we study scaling in the compound eyes of workers of the wood ant, Formica rufa, from different colonies within a single population. Workers' eye area increased with body size in all the colonies showing a negative allometry. However, both the slope and intercept of some allometric scaling relationships differed significantly among colonies. Moreover, though mean facet diameter and facet number increased with body size, some colonies primarily increased facet number whereas others increased facet diameter, showing that the cellular level processes underlying organ scaling differed among colonies. Thus, the rules that govern scaling at the organ and cellular levels can differ even within a single population.

  3. Causes of intraspecific variation in body size among trematode metacercariae.

    PubMed

    Saldanha, I; Leung, T L F; Poulin, R

    2009-09-01

    Inequalities in body size among adult helminths can result in inequalities in reproductive output, with consequences for population dynamics and genetics. These inequalities can result from growth differences among larval worms inside intermediate hosts that persist into the adult stage. Here, we investigate the effects of both host body size and intensity of infection on the sizes of metacercariae of the trematode Maritrema novaezealandensis (Microphallidae) inside their second intermediate host, the isopod Paridotea ungulata (Idoteidae). Among the more than 1500 metacercariae recovered and individually measured, there was no relationship between the mean diameter of metacercarial cysts per isopod and isopod body length. However, intensity of infection correlated negatively with the mean diameter of cysts within an isopod, i.e. metacercariae in crowded infections attained smaller sizes on average. In contrast, the variability in cyst sizes per isopod, measured as the coefficient of variation, was independent of both isopod body length and infection intensity. Our results show that a disproportionate number of relatively small metacercariae come from the relatively few hosts in which a large fraction of all metacercariae are aggregated. The combination of aggregation and intensity-dependent growth generates inequalities in sizes among metacercariae that will be passed on to adult worm populations in definitive hosts.

  4. Double diameter boring tool

    DOEpatents

    Ashbaugh, F.A.; Murry, K.R.

    1986-02-10

    A boring tool and a method of operation are provided for boring two concentric holes of precision diameters and depths in a single operation. The boring tool includes an elongated tool body, a shank for attachment to a standard adjustable boring head which is used on a manual or numerical control milling machine and first and second diametrically opposed cutting flutes formed for cutting in opposite directions. The diameter of the elongated tool body is substantially equal to the distance from the first flute tip to the axis of rotation plus the distance from the second flute tip to the axis of rotation. The axis of rotation of the tool is spaced from the tool centerline a distance substantially equal to one-half the distance from the second flute tip to the axis of rotation minus one-half the distance from the first flute tip to the axis of rotation. The method includes the step of inserting the boring tool into the boring head, adjusting the distance between the tool centerline and the tool axis of rotation as described above and boring the two concentric holes.

  5. Double diameter boring tool

    DOEpatents

    Ashbaugh, Fred N.; Murry, Kenneth R.

    1988-12-27

    A boring tool and a method of operation are provided for boring two concentric holes of precision diameters and depths in a single operation. The boring tool includes an elongated tool body, a shank for attachment to a standard adjustable boring head which is used on a manual or numerical control milling machine and first and second diametrically opposed cutting edges formed for cutting in opposite directions. The diameter of the elongated tool body is substantially equal to the distance from the first cutting edge tip to the axis of rotation plus the distance from the second cutting edge tip to the axis of rotation. The axis of rotation of the tool is spaced from the tool centerline a distance substantially equal to one-half the distance from the second cutting edge tip to the axis of rotation minus one-half the distance from the first cutting edge tip to the axis of rotation. The method includes the step of inserting the boring tool into the boring head, adjusting the distance between the tool centerline and the tool axis of rotation as described above and boring the two concentric holes.

  6. Double diameter boring tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashbaugh, F.A.; Murry, K.R.

    A boring tool and a method of operation are provided for boring two concentric holes of precision diameters and depths in a single operation. The boring tool includes an elongated tool body, a shank for attachment to a standard adjustable boring head which is used on a manual or numerical control milling machine and first and second diametrically opposed cutting flutes formed for cutting in opposite directions. The diameter of the elongated tool body is substantially equal to the distance from the first flute tip to the axis of rotation plus the distance from the second flute tip to themore » axis of rotation. The axis of rotation of the tool is spaced from the tool centerline a distance substantially equal to one-half the distance from the second flute tip to the axis of rotation minus one-half the distance from the first flute tip to the axis of rotation. The method includes the step of inserting the boring tool into the boring head, adjusting the distance between the tool centerline and the tool axis of rotation as described above and boring the two concentric holes.« less

  7. Histology confirms that macroscopic evaluation of ovaries is a valid method for the assessment of the reproductive status in wild boar.

    PubMed

    Gethöffer, Friederike; Pfarrer, Christiane; Siebert, Ursula

    2018-06-01

    Research on reproduction and fertility is an essential fundament of management strategies in European wild boar. Concerning the examination of the reproductive tract, methods still lack conformity and comparability. So far the reproductive status of female wild boar has been assessed by ovarian macroscopic examination. In order to find out if this is a valid method, 21 ovaries of 8-34 months old animals covering (early) follicular phase and cyclic inactivity were evaluated microscopically. Number and dimension of follicles as well as the occurrence of atretic follicles were compared and related to age, weight, ovary weight and size of ovary. For this study, 21 ovaries of the right side of each animal were weighed and measured. The diameter of the functional bodies was measured and functional bodies were counted. Size of ovary was calculated by length*width*height (cm 3 ). Macroscopically, follicles were classified into four categories by diameter: F1 (0.2-0.3 cm), F2 (0.4-0.5 cm), F3 (0.6-0.8 cm) and F4 (0.9-1.3 cm). Microscopically, antral follicles of every 10th slice per section of each ovary were counted and classified into three categories by diameter: F0 (≥2 mm), FS (1-2 mm) and FXS (≤1 mm). In follicles with a diameter greater than 2 mm (F0), length and width were measured from the beginning of theca interna. Results showed that age and weight of wild boars were highly correlated (cor = 0.845, p < 0.001). Wild boar of higher age and weight showed higher ovary weight, but this was not significant (p = 0.135 (age), p = 0.329 (weight)). Although the number of macroscopically seen follicles differed widely by animal, microscopically only one ovary showed only small tertiary follicles. Animals with bigger follicles showed a significantly (p = 0.006) smaller number of small and smallest tertiary follicles. The number of tertiary follicles (F0) was not significantly influenced by age or carcass weight (p = 0.460, 0.159). Older and heavier animals showed significantly less FX and FXS (p < 0.001). Comparison of the follicular composition of young wild boar ovaries with domestic pig research allows the conclusion that assessment of cyclic activity and near puberty is possible. However, due to the fact that puberty is a long term biological progress, defining the time of sexual maturity will always be an estimate. Nevertheless, microscopic examination confirmed the macroscopic findings, including follicular dimensions and developmental stage allowing the conclusion that macroscopic evaluation of ovarian functional bodies in wild boar is an easy and reliable way to assess reproductive performance. Copyright © 2018 Elsevier Inc. All rights reserved.

  8. Flow-field characteristics of high-temperature annular buoyant jets and their development laws influenced by ventilation system.

    PubMed

    Wang, Yi; Huang, Yanqiu; Liu, Jiaping; Wang, Hai; Liu, Qiuhan

    2013-01-01

    The flow-field characteristics of high-temperature annular buoyant jets as well as the development laws influenced by ventilation system were studied using numerical methods to eliminate the pollutants effectively in this paper. The development laws of high-temperature annular buoyant jets were analyzed and compared with previous studies, including radial velocity distribution, axial velocity and temperature decay, reattachment position, cross-section diameter, volumetric flow rate, and velocity field characteristics with different pressures at the exhaust hood inlet. The results showed that when the ratio of outer diameter to inner diameter of the annulus was smaller than 5/2, the flow-field characteristics had significant difference compared to circular buoyant jets with the same outer diameter. For similar diameter ratios, reattachment in this paper occurred further downstream in contrast to previous study. Besides, the development laws of volumetric flow rate and cross-section diameter were given with different initial parameters. In addition, through analyzing air distribution characteristics under the coupling effect of high-temperature annular buoyant jets and ventilation system, it could be found that the position where maximum axial velocity occurred was changing gradually when the pressure at the exhaust hood inlet changed from 0 Pa to -5 Pa.

  9. Flow-Field Characteristics of High-Temperature Annular Buoyant Jets and Their Development Laws Influenced by Ventilation System

    PubMed Central

    Liu, Jiaping; Wang, Hai; Liu, Qiuhan

    2013-01-01

    The flow-field characteristics of high-temperature annular buoyant jets as well as the development laws influenced by ventilation system were studied using numerical methods to eliminate the pollutants effectively in this paper. The development laws of high-temperature annular buoyant jets were analyzed and compared with previous studies, including radial velocity distribution, axial velocity and temperature decay, reattachment position, cross-section diameter, volumetric flow rate, and velocity field characteristics with different pressures at the exhaust hood inlet. The results showed that when the ratio of outer diameter to inner diameter of the annulus was smaller than 5/2, the flow-field characteristics had significant difference compared to circular buoyant jets with the same outer diameter. For similar diameter ratios, reattachment in this paper occurred further downstream in contrast to previous study. Besides, the development laws of volumetric flow rate and cross-section diameter were given with different initial parameters. In addition, through analyzing air distribution characteristics under the coupling effect of high-temperature annular buoyant jets and ventilation system, it could be found that the position where maximum axial velocity occurred was changing gradually when the pressure at the exhaust hood inlet changed from 0 Pa to −5 Pa. PMID:24000278

  10. Inclined Bodies of Various Cross Sections at Supersonic Speeds

    NASA Technical Reports Server (NTRS)

    Jorgensen, Leland H.

    1958-01-01

    To aid in assessing effects of cross-sectional shape on body aerodynamics, the forces and moments have been measured for bodies with circular, elliptic, square, and triangular cross sections at Mach numbers 1.98 and 3.88. Results for bodies with noncircular cross sections have been compared with results for bodies of revolution having the same axial distribution of cross-sectional area (and, thus, the same equivalent fineness ratio). Comparisons have been made for bodies of fineness ratios 6 and 10 at angles of attack from 0 deg to about 20 deg and for Reynolds numbers, based on body length, of 4.0 x 10(exp 6) and 6.7 x 10(exp 6). The results of this investigation show that distinct aerodynamic advantages can be obtained by using bodies with noncircular cross sections. At certain angles of bank, bodies with elliptic, square, and triangular cross sections develop considerably greater lift and lift-drag ratios than equivalent bodies of revolution. For bodies with elliptic cross sections, lift and pitching-moment coefficients can be correlated with corresponding coefficients for equivalent circular bodies. It has been found that the ratios of lift and pitching-moment coefficients for an elliptic body to those for an equivalent circular body are practically constant with change in both angle of attack and Mach number. These lift and moment ratios are given very accurately by slender-body theory. As a result of this agreement, the method of NACA Rep. 1048 for computing forces and moments for bodies of revolution has been simply extended to bodies with elliptic cross sections. For the cases considered (elliptic bodies of fineness ratios 6 and 10 having cross-sectional axis ratios of 1.5 and 2), agreement of theory with experiment is very good. As a supplement to the force and moment results, visual studies of the flow over bodies have been made by use of the vapor-screen, sublimation, and white-lead techniques. Photographs from these studies are included in the report.

  11. Monte Carlo based dosimetry for neutron capture therapy of brain tumors

    NASA Astrophysics Data System (ADS)

    Zaidi, Lilia; Belgaid, Mohamed; Khelifi, Rachid

    2016-11-01

    Boron Neutron Capture Therapy (BNCT) is a biologically targeted, radiation therapy for cancer which combines neutron irradiation with a tumor targeting agent labeled with a boron10 having a high thermal neutron capture cross section. The tumor area is subjected to the neutron irradiation. After a thermal neutron capture, the excited 11B nucleus fissions into an alpha particle and lithium recoil nucleus. The high Linear Energy Transfer (LET) emitted particles deposit their energy in a range of about 10μm, which is of the same order of cell diameter [1], at the same time other reactions due to neutron activation with body component are produced. In-phantom measurement of physical dose distribution is very important for BNCT planning validation. Determination of total absorbed dose requires complex calculations which were carried out using the Monte Carlo MCNP code [2].

  12. Lymph node hemangioma in one-humped camel

    PubMed Central

    Aljameel, M.A.; Halima, M.O.

    2015-01-01

    Hemangioma is a benign tumor of blood and lymphatic vessels. It is common in skin, mucosa and soft tissues, and its occurrence in lymph nodes is extremely rare. A 10 year-old she-camel was slaughtered at Nyala slaughterhouse, South Darfur State, Sudan. Grossly, the carcass was emaciated. The left ventral superficial cervical lymph node was enlarged, hard on palpation and protruded outside the body. Its cut surface was dark red in color and measured (18 cm) in diameter. Histopathologically, the sections revealed vascular masses were composed of non-encapsulated clusters of small and medium sized with thick and thin-walled, filled with blood, separated by courageous stroma and surrounded by closely packed proliferating capillaries. To the best of our knowledge, this is the first record of the left ventral superficial cervical lymph node hemangioma in a camel in the Sudan. PMID:26753134

  13. An experimental investigation of wall-interference effects for parachutes in closed wind tunnels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macha, J.M.; Buffington, R.J.

    1989-09-01

    A set of 6-ft-diameter ribbon parachutes (geometric porosities of 7%, 15%, and 30%) was tested in various subsonic wind tunnels covering a range of geometric blockages from 2% to 35%. Drag, base pressure, and inflated geometry were measured under full-open, steady-flow conditions. The result drag areas and pressure coefficients were correlated with the bluff-body blockage parameter (i.e., drag area divided by tunnel cross-sectional area) according to the blockage theory of Maskell. The data show that the Maskell theory provides a simple, accurate correction for the effective increase in dynamic pressure caused by wall constraint for both single parachutes and clusters.more » For single parachutes, the empirically derived blockage factor K{sub M} has the value of 1.85, independent of canopy porosity. Derived values of K{sub M} for two- and three-parachute clusters are 1.35 and 1.59, respectively. Based on the photometric data, there was no deformation of the inflated shape of the single parachutes up to a geometric blockage of 22%. In the case of the three-parachute cluster, decreases in both the inflated diameter and the spacing among member parachutes were observed at a geometric blockage of 35%. 11 refs., 9 figs., 3 tabs.« less

  14. Pancreatic polypeptide cells of rat pancreas after chronic ethanol feeding.

    PubMed

    Koko, V; Todorović, V; Drndarević, N; Glisić, R; Nedeljković, M; Nikolić, A

    2001-05-01

    Male Wistar rats, (2 months old) were randomly divided into two groups according to the diet offered (C-control and E-ethanol treated rats). Final body weight was significantly increased but pancreatic weight as a percentage of body weight was decreased in ethanol treated rats. Volume density, number of pancreatic poly peptide (PP)-cells per islet and per micron 2 of islet were significantly increased. PP-cells were abundant and occupied the whole periphery of islets in the splenic part of the pancreas. Those cells showed strong immunopositivity. At the ultrastructural level PP granules had predominantly less electron density. The mean diameter of PP granules was significantly increased and the number of granules of larger diameter was greater in the E group of rats, than in the controls.

  15. Silicon nitride/silicon carbide composite powders

    DOEpatents

    Dunmead, Stephen D.; Weimer, Alan W.; Carroll, Daniel F.; Eisman, Glenn A.; Cochran, Gene A.; Susnitzky, David W.; Beaman, Donald R.; Nilsen, Kevin J.

    1996-06-11

    Prepare silicon nitride-silicon carbide composite powders by carbothermal reduction of crystalline silica powder, carbon powder and, optionally, crystalline silicon nitride powder. The crystalline silicon carbide portion of the composite powders has a mean number diameter less than about 700 nanometers and contains nitrogen. The composite powders may be used to prepare sintered ceramic bodies and self-reinforced silicon nitride ceramic bodies.

  16. Plasma arc welding torch having means for vortexing plasma gas exiting the welding torch

    NASA Technical Reports Server (NTRS)

    Rybicki, Daniel J. (Inventor); Mcgee, William F. (Inventor)

    1994-01-01

    A plasma arc welding torch is described wherein a plasma gas is directed through the body of the welding torch and out of the body across the tip of the welding electrode disposed at the forward end of the body. The plasma gas is provided with a vortexing motion prior to exiting the body by a vortex motion imparting member which is mounted in an orifice housing member and carried in the forward portion of the torch body. The orifice housing member is provided with an orifice of an predetermined diameter through which the electric arc and the plasma gas exits.

  17. A rotating bluff-body disc for reduced variability in wind tunnel aerosol studies.

    PubMed

    Koehler, Kirsten A; Anthony, T Renee; van Dyke, Michael; Volckens, John

    2011-01-01

    A rotating bluff-body disc (RBD) was developed to reduce spatiotemporal variability associated with sampling supermicron aerosol in low-velocity wind tunnels. The RBD is designed to rotate eight personal aerosol samplers around a circular path in a forward-facing plane aligned with the wind tunnel cross section. Rotation of the RBD allows each sampler to traverse an identical path about the wind tunnel cross section, which reduces the effects of spatial heterogeneity associated with dispersing supermicron aerosol in low-velocity wind tunnels. Samplers are positioned on the face of the RBD via sampling ports, which connect to an air manifold on the back of the disc. Flow through each sampler was controlled with a critical orifice or needle valve, allowing air to be drawn through the manifold with a single pump. A metal tube, attached to this manifold, serves as both the axis of rotation and the flow conduction path (between the samplers and the vacuum source). Validation of the RBD was performed with isokinetic samplers and 37-mm cassettes. For facing-the-wind tests, the rotation of the RBD significantly decreased intra-sampler variability when challenged with particle diameters from 1 to 100 μm. The RBD was then employed to determine the aspiration efficiency of Institute of Occupational Medicine (IOM) personal samplers under a facing-the-wind condition. Operation of IOM samplers on the RBD reduced the between-sampler variability for all particle sizes tested.

  18. An enhanced droplet-based liquid microjunction surface sampling system coupled with HPLC-ESI-MS/MS for spatially resolved analysis

    DOE PAGES

    Van Berkel, Gary J.; Weiskittel, Taylor M.; Kertesz, Vilmos

    2014-11-07

    Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparatemore » height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. Lastly, the merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade (“crude”) cut mouse tissue.« less

  19. An enhanced droplet-based liquid microjunction surface sampling system coupled with HPLC-ESI-MS/MS for spatially resolved analysis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Van Berkel, Gary J.; Weiskittel, Taylor M.; Kertesz, Vilmos

    Droplet-based liquid microjunction surface sampling coupled with high-performance liquid chromatography (HPLC)-electrospray ionization (ESI)-tandem mass spectrometry (MS/MS) for spatially resolved analysis provides the possibility of effective analysis of complex matrix samples and can provide a greater degree of chemical information from a single spot sample than is typically possible with a direct analysis of an extract. Described here is the setup and enhanced capabilities of a discrete droplet liquid microjunction surface sampling system employing a commercially available CTC PAL autosampler. The system enhancements include incorporation of a laser distance sensor enabling unattended analysis of samples and sample locations of dramatically disparatemore » height as well as reliably dispensing just 0.5 μL of extraction solvent to make the liquid junction to the surface, wherein the extraction spot size was confined to an area about 0.7 mm in diameter; software modifications improving the spatial resolution of sampling spot selection from 1.0 to 0.1 mm; use of an open bed tray system to accommodate samples as large as whole-body rat thin tissue sections; and custom sample/solvent holders that shorten sampling time to approximately 1 min per sample. Lastly, the merit of these new features was demonstrated by spatially resolved sampling, HPLC separation, and mass spectral detection of pharmaceuticals and metabolites from whole-body rat thin tissue sections and razor blade (“crude”) cut mouse tissue.« less

  20. Average Skin-Friction Drag Coefficients from Tank Tests of a Parabolic Body of Revolution (NACA RM-10)

    NASA Technical Reports Server (NTRS)

    Mottard, Elmo J; Loposer, J Dan

    1954-01-01

    Average skin-friction drag coefficients were obtained from boundary-layer total-pressure measurements on a parabolic body of revolution (NACA rm-10, basic fineness ratio 15) in water at Reynolds numbers from 4.4 x 10(6) to 70 x 10(6). The tests were made in the Langley tank no. 1 with the body sting-mounted at a depth of two maximum body diameters. The arithmetic mean of three drag measurements taken around the body was in good agreement with flat-plate results, but, apparently because of the slight surface wave caused by the body, the distribution of the boundary layer around the body was not uniform over part of the Reynolds number range.

  1. Spanwise transition section for blended wing-body aircraft

    NASA Technical Reports Server (NTRS)

    Hawley, Arthur V. (Inventor)

    1999-01-01

    A blended wing-body aircraft includes a central body, a wing, and a transition section which interconnects the body and the wing on each side of the aircraft. The two transition sections are identical, and each has a variable chord length and thickness which varies in proportion to the chord length. This enables the transition section to connect the thin wing to the thicker body. Each transition section has a negative sweep angle.

  2. Growth of nanostructures with controlled diameter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Pfefferle, Lisa; Haller, Gary; Ciuparu, Dragos

    2009-02-03

    Transition metal-substituted MCM-41 framework structures with a high degree of structural order and a narrow pore diameter distribution were reproducibly synthesized by a hydrothermal method using a surfactant and an anti-foaming agent. The pore size and the mesoporous volume depend linearly on the surfactant chain length. The transition metals, such as cobalt, are incorporated substitutionally and highly dispersed in the silica framework. Single wall carbon nanotubes with a narrow diameter distribution that correlates with the pore diameter of the catalytic framework structure were prepared by a Boudouard reaction. Nanostructures with a specified diameter or cross-sectional area can therefore be predictablymore » prepared by selecting a suitable pore size of the framework structure.« less

  3. Quantitative hard x-ray phase contrast imaging of micropipes in SiC

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kohn, V. G.; Argunova, T. S.; Je, J. H., E-mail: jhje@postech.ac.kr

    2013-12-15

    Peculiarities of quantitative hard x-ray phase contrast imaging of micropipes in SiC are discussed. The micropipe is assumed as a hollow cylinder with an elliptical cross section. The major and minor diameters can be restored using the least square fitting procedure by comparing the experimental data, i.e. the profile across the micropipe axis, with those calculated based on phase contrast theory. It is shown that one projection image gives an information which does not allow a complete determination of the elliptical cross section, if an orientation of micropipe is not known. Another problem is a weak accuracy in estimating themore » diameters, partly because of using pink synchrotron radiation, which is necessary because a monochromatic beam intensity is not sufficient to reveal the weak contrast from a very small object. The general problems of accuracy in estimating the two diameters using the least square procedure are discussed. Two experimental examples are considered to demonstrate small as well as modest accuracies in estimating the diameters.« less

  4. Metaphase II oocytes from human unilaminar follicles grown in a multi-step culture system.

    PubMed

    McLaughlin, M; Albertini, D F; Wallace, W H B; Anderson, R A; Telfer, E E

    2018-03-01

    Can complete oocyte development be achieved from human ovarian tissue containing primordial/unilaminar follicles and grown in vitro in a multi-step culture to meiotic maturation demonstrated by the formation of polar bodies and a Metaphase II spindle? Development of human oocytes from primordial/unilaminar stages to resumption of meiosis (Metaphase II) and emission of a polar body was achieved within a serum free multi-step culture system. Complete development of oocytes in vitro has been achieved in mouse, where in vitro grown (IVG) oocytes from primordial follicles have resulted in the production of live offspring. Human oocytes have been grown in vitro from the secondary/multi-laminar stage to obtain fully grown oocytes capable of meiotic maturation. However, there are no reports of a culture system supporting complete growth from the earliest stages of human follicle development through to Metaphase II. Ovarian cortical biopsies were obtained with informed consent from women undergoing elective caesarean section (mean age: 30.7 ± 1.7; range: 25-39 years, n = 10). Laboratory setting. Ovarian biopsies were dissected into thin strips, and after removal of growing follicles were cultured in serum free medium for 8 days (Step 1). At the end of this period secondary/multi-laminar follicles were dissected from the strips and intact follicles 100-150 μm in diameter were selected for further culture. Isolated follicles were cultured individually in serum free medium in the presence of 100 ng/ml of human recombinant Activin A (Step 2). Individual follicles were monitored and after 8 days, cumulus oocyte complexes (COCs) were retrieved by gentle pressure on the cultured follicles. Complexes with complete cumulus and adherent mural granulosa cells were selected and cultured in the presence of Activin A and FSH on membranes for a further 4 days (Step 3). At the end of Step 3, complexes containing oocytes >100 μm diameter were selected for IVM in SAGE medium (Step 4) then fixed for analysis. Pieces of human ovarian cortex cultured in serum free medium for 8 days (Step 1) supported early follicle growth and 87 secondary follicles of diameter 120 ± 6 μm (mean ± SEM) could be dissected for further culture. After a further 8 days, 54 of the 87 follicles had reached the antral stage of development. COCs were retrieved by gentle pressure from the cultured follicles and those with adherent mural granulosa cells (n = 48) were selected and cultured for a further 4 days (Step 3). At the end of Step 3, 32 complexes contained oocytes >100 μm diameter were selected for IVM (Step 4). Nine of these complexes contained polar bodies within 24 h and all polar bodies were abnormally large. Confocal immuno-histochemical analysis showed the presence of a Metaphase II spindle confirming that these IVG oocytes had resumed meiosis but their developmental potential is unknown. This is a small number of samples but provides proof of concept that complete development of human oocytes can occur in vitro. Further optimization with morphological evaluation and fertilization potential of IVG oocytes is required to determine whether they are normal. The ability to develop human oocytes from the earliest follicular stages in vitro through to maturation and fertilization would benefit fertility preservation practice. Funded by MRC Grants (G0901839 and MR/L00299X/1). No competing interests.

  5. Body mass index and waist circumference in early adulthood are associated with thoracolumbar spine shape at age 60-64: The Medical Research Council National Survey of Health and Development.

    PubMed

    Pavlova, Anastasia V; Muthuri, Stella G; Cooper, Rachel; Saunders, Fiona R; Gregory, Jennifer S; Barr, Rebecca J; Martin, Kathryn R; Adams, Judith E; Kuh, Diana; Hardy, Rebecca J; Aspden, Richard M

    2018-01-01

    This study investigated associations between measures of adiposity from age 36 and spine shape at 60-64 years. Thoracolumbar spine shape was characterised using statistical shape modelling on lateral dual-energy x-ray absorptiometry images of the spine from 1529 participants of the MRC National Survey of Health and Development, acquired at age 60-64. Associations of spine shape modes with: 1) contemporaneous measures of total and central adiposity (body mass index (BMI), waist circumference (WC)) and body composition (android:gynoid fat mass ratio and lean and fat mass indices, calculated as whole body (excluding the head) lean or fat mass (kg) divided by height2 (m)2); 2) changes in total and central adiposity between age 36 and 60-64 and 3) age at onset of overweight, were tested using linear regression models. Four modes described 79% of the total variance in spine shape. In men, greater lean mass index was associated with a larger lordosis whereas greater fat mass index was associated with straighter spines. Greater current BMI was associated with a more uneven curvature in men and with larger anterior-posterior (a-p) vertebral diameters in both sexes. Greater WC and fat mass index were also associated with a-p diameter in both sexes. There was no clear evidence that gains in BMI and WC during earlier stages of adulthood were associated with spine shape but younger onset of overweight was associated with a more uneven spine and greater a-p diameter. In conclusion, sagittal spine shapes had different associations with total and central adiposity; earlier onset of overweight and prior measures of WC were particularly important.

  6. Effects of body shape on the aerodynamics of a body of revolution at Mach numbers from 1.6 to 4.6

    NASA Technical Reports Server (NTRS)

    Spearman, M. L.

    1985-01-01

    The aerodnamic characteristics for several bodies of revolution have been determined from wind tunnel tests at Mach numbers from 1.6 to 4.63. Six bodies, each having a length-to-diameter ratio of 6.67, were investigated. Geometric modifications included forebody shape, afterbody shape, and midsection slope. Significant aerodynamic changes were observed to be functions of geometric change and Mach number. Because of the aerodynamic dependence on geometry as well as Mach number, it is obvious that a number of trades must be considered in selecting a projectile shape.

  7. Cranial injury caused by penetrating non-missile foreign body: an autopsy case.

    PubMed

    Eren, B; Türkmen, N; Toprak Ergönen, A; Gündogmus, U N

    2012-10-01

    Presented case was 32-year-old male marble worker, who underwent industrial accident at workplace. On gross physical examination; on forehead region round skin wound in 0.9 cm diameter was detected, radiological examination showed the image of metallic object. in the skull cavity. Brain dissection showed obvious brain injury, haemorrahge explaining the pattern of injury caused by the metallic bodys path, from left frontal lobe to the left cerebellar hemisphere was identified. We presented rare case of penetrating injury of the cranial region caused by non-missile foreign body. cranial injury - non-missile foreign body - autopsy.

  8. Middle cerebral artery diameter changes during rhythmic handgrip exercise in humans.

    PubMed

    Verbree, J; Bronzwaer, Agt; van Buchem, M A; Daemen, Mjap; van Lieshout, J J; van Osch, Mjp

    2017-08-01

    Transcranial Doppler (TCD) sonography is a frequently employed technique for quantifying cerebral blood flow by assuming a constant arterial diameter. Given that exercise increases arterial pressure by sympathetic activation, we hypothesized that exercise might induce a change in the diameter of large cerebral arteries. Middle cerebral artery (MCA) cross-sectional area was assessed in response to handgrip exercise by direct magnetic resonance imaging (MRI) observations. Twenty healthy subjects (11 female) performed three 5 min bouts of rhythmic handgrip exercise at 60% maximum voluntary contraction, alternated with 5 min of rest. High-resolution 7 T MRI scans were acquired perpendicular to the MCA. Two blinded observers manually determined the MCA cross-sectional area. Sufficient image quality was obtained in 101 MCA-scans of 19 subjects (age-range 20-59 years). Mixed effects modelling showed that the MCA cross-sectional area decreased by 2.1 ± 0.8% (p = 0.01) during handgrip, while the heart rate increased by 11 ± 2% (p < 0.001) at constant end-tidal CO 2 (p = 0.10). In conclusion, the present study showed a 2% decrease in MCA cross-sectional area during rhythmic handgrip exercise. This further strengthens the current concept of sympathetic control of large cerebral arteries, showing in vivo vasoconstriction during exercise-induced sympathetic activation. Moreover, care must be taken when interpreting TCD exercise studies as diameter constancy cannot be assumed.

  9. Preparation of a nano emodin transfersome and study on its anti-obesity mechanism in adipose tissue of diet-induced obese rats

    PubMed Central

    2014-01-01

    Objective To describe the preparation of nano emodin transfersome (NET) and investigate its effect on mRNA expression of adipose triglyceride lipase (ATGL) and G0/G1 switch gene 2 (G0S2) in adipose tissue of diet-induced obese rats. Methods NET was prepared by film-ultrasonic dispersion method. The effects of emodin components at different ratios on encapsulation efficiency were investigated.The NET envelopment rate was determined by ultraviolet spectrophotometry. The particle size and Zeta potential of NET were evaluated by Zetasizer analyzer. Sixty male SD rats were assigned to groups randomly. After 8-week treatment, body weight, wet weight of visceral fat and the percentage of body fat (PBF) were measured. Fasting blood glucose and serum lipid levels were determined. The adipose tissue section was HE stained, and the cellular diameter and quantity of adipocytes were evaluated by light microscopy. The mRNA expression of ATGL and G0S2 from the peri-renal fat tissue was assayed by RT-PCR. Results The appropriate formulation was deoxycholic acid sodium salt vs. phospholipids 1:8, cholesterol vs. phospholipids 1:3, vitamin Evs. phospholipids 1:20, and emodin vs. phospholipid 1:6. Zeta potential was −15.11 mV, and the particle size was 292.2 nm. The mean encapsulation efficiency was (69.35 ± 0.25)%. Compared with the obese model group, body weight, wet weight of visceral fat, PBF and mRNA expression of G0S2 from peri-renal fat tissue were decreased significantly after NET treatment (all P < 0.05), while high-density lipoprotein cholesterol (HDL-C), the diameter of adipocytes and mRNA expression of ATGL from peri-renal fat tissue were increased significantly (all P < 0.05). Conclusion The preparation method is simple and reasonable. NET with negative electricity was small and uniform in particle size, with high encapsulation efficiency and stability. NET could reduce body weight and adipocyte size, and this effect was associated with the up-regulation of ATGL, down-regulation of G0S2 expression in the adipose tissue, and improved insulin sensitivity. PMID:24641917

  10. Ab initio density functional theory investigation of crystalline bundles of polygonized single-walled silicon carbide nanotubes

    NASA Astrophysics Data System (ADS)

    Moradian, Rostam; Behzad, Somayeh; Chegel, Raad

    2008-11-01

    By using ab initio density functional theory, the structural characterizations and electronic properties of two large-diameter (13, 13) and (14, 14) armchair silicon carbide nanotube (SiCNT) bundles are investigated. Full structural optimizations show that the cross sections of these large-diameter SiCNTs in the bundles have a nearly hexagonal shape. The effects of inter-tube coupling on the electronic dispersions of large-diameter SiCNT bundles are demonstrated. By comparing the band structures of the triangular lattices of (14, 14) SiCNTs with nearly hexagonal and circular cross sections we found that the polygonization of the tubes in the bundle leads to a further dispersion of the occupied bands and an increase in the bandgap by 0.18 eV.

  11. Ab initio density functional theory investigation of crystalline bundles of polygonized single-walled silicon carbide nanotubes.

    PubMed

    Moradian, Rostam; Behzad, Somayeh; Chegel, Raad

    2008-11-19

    By using ab initio density functional theory, the structural characterizations and electronic properties of two large-diameter (13, 13) and (14, 14) armchair silicon carbide nanotube (SiCNT) bundles are investigated. Full structural optimizations show that the cross sections of these large-diameter SiCNTs in the bundles have a nearly hexagonal shape. The effects of inter-tube coupling on the electronic dispersions of large-diameter SiCNT bundles are demonstrated. By comparing the band structures of the triangular lattices of (14, 14) SiCNTs with nearly hexagonal and circular cross sections we found that the polygonization of the tubes in the bundle leads to a further dispersion of the occupied bands and an increase in the bandgap by 0.18 eV.

  12. Silicon nitride/silicon carbide composite densified materials prepared using composite powders

    DOEpatents

    Dunmead, S.D.; Weimer, A.W.; Carroll, D.F.; Eisman, G.A.; Cochran, G.A.; Susnitzky, D.W.; Beaman, D.R.; Nilsen, K.J.

    1997-07-01

    Prepare silicon nitride-silicon carbide composite powders by carbothermal reduction of crystalline silica powder, carbon powder and, optionally, crystalline silicon nitride powder. The crystalline silicon carbide portion of the composite powders has a mean number diameter less than about 700 nanometers and contains nitrogen. The composite powders may be used to prepare sintered ceramic bodies and self-reinforced silicon nitride ceramic bodies.

  13. Deflection and fragmentation of near-earth asteroids

    NASA Technical Reports Server (NTRS)

    Ahrens, Thomas J.; Harris, Alan W.

    1992-01-01

    The collision with earth of near-earth asteroids or comet nuclei poses a potential threat to mankind. Objects about 100 m in diameter could be diverted from an earth-crossing trajectory by the impact of a rocket-launched mass, but for larger bodies nuclear explosions seem to be the only practical means of deflection. Fragmentation of the body by nuclear charges is less efficient or secure.

  14. High-Clearance Six-Wheel Suspension

    NASA Technical Reports Server (NTRS)

    Bickler, Donald B.

    1992-01-01

    Multilevered suspension system gives body of vehicle high clearance and allows wheels to be steered independently. Suspension linkages above wheels enable body to skim over obstacles as high as wheel. Levers and independently steered wheels enable vehicle to climb steps 1 1/2 wheel diameters high and cross gaps 1 3/4 wide. Adaptable to off-the-road recreational vehicles, military scout vehicles, and robotic emergency vehicles.

  15. Relationship between Device Size and Body Weight in Dogs with Patent Ductus Arteriosus Undergoing Amplatz Canine Duct Occluder Deployment.

    PubMed

    Wesselowski, S; Saunders, A B; Gordon, S G

    2017-09-01

    Deployment of the Amplatz Canine Duct Occluder (ACDO) is the preferred method for minimally invasive occlusion of patent ductus arteriosus (PDA) in dogs, with appropriate device sizing crucial to successful closure. Dogs of any body weight can be affected by PDA. To describe the range of ACDO sizes deployed in dogs of various body weights for improved procedural planning and inventory selection and to investigate for correlation between minimal ductal diameter (MDD) and body weight. A total of 152 dogs undergoing ACDO deployment between 2008 and 2016. Body weight, age, breed, sex, and MDD obtained by angiography (MDD-A), MDD obtained by transesophageal echocardiography (MDD-TEE), and ACDO size deployed were retrospectively evaluated. Correlation between body weight and ACDO size, MDD-A and MDD-TEE was poor, with R-squared values of 0.4, 0.36, and 0.3, respectively. Femoral artery diameter in the smallest population of dogs placed inherent limitations on the use of larger device sizes, with no limitations on the wide range of device sizes required as patient size increased. The most commonly used ACDO devices were size 3 through 6, representing 57% of the devices deployed within the entire study population. Patent ductus arteriosus anatomy varies on an individual basis, with poor correlation between MDD and body weight. Weight-based assumptions about expected ACDO device size for a given patient are not recommended. Copyright © 2017 The Authors. Journal of Veterinary Internal Medicine published by Wiley Periodicals, Inc. on behalf of the American College of Veterinary Internal Medicine.

  16. A novel hydrodynamic approach of drag-reducing polymers to improve left ventricular hypertrophy and aortic remodeling in spontaneously hypertensive rats.

    PubMed

    Zhang, Xinlu; Wang, Xu; Hu, Feng; Zhou, Boda; Chen, Hai-Bin; Zha, Daogang; Liu, Yili; Guo, Yansong; Zheng, Lemin; Xiu, Jiancheng

    Drag-reducing polymers (DRPs), when added in minute concentrations, have been shown to decrease peripheral vascular resistance. In this study, the effect of DRPs on the hypertension-induced left ventricular hypertrophy and aortic remodeling was evaluated in spontaneously hypertensive rats (SHR). Male SHR and age-matched Wistar rats were divided into four groups and received intravenous injection of normal saline (NS) or DRPs. Body weight (BW), heart rate (HR) and systolic blood pressure (SBP) were measured. Echocardiography was used to evaluate the changes in left ventricle (LV) function and global wall motion. The LV and aorta were stained by hematoxylin and eosin. Cell size of cardiomyocytes and aortic medial thickness were evaluated for each section. The expression of endothelin-1 (ET-1) of LV and aorta was examined by quantitative reverse transcription polymerase chain reaction (qRT-PCR) and immunohistochemistry. There was no significant difference in the increase of SBP among SHR + NS, SHR + 10DRP and SHR + 20DRP groups. SHR + NS group had markedly smaller left ventricular end-systolic diameter and left ventricular end-diastolic diameter but bigger anterior and posterior systolic wall thicknesses, while there was no significant difference in fractional shortening and ejection fraction. The cross-sectional areas (CSAs) of cardiomyocytes and the medial thickness of the aorta in SHR + 10 (ppm) DRP and SHR + 20 (ppm) DRP groups were significantly reduced compared with SHR + NS group. The expression of ET-1 in SHR + 10DRP and SHR + 20DRP groups was significantly attenuated. These results suggest that chronic treatment with DRPs can protect against left ventricular hypertrophy and aortic remodeling. DRPs may offer a new approach to the treatment of left ventricular hypertrophy and aortic remodeling caused by hypertension.

  17. A novel hydrodynamic approach of drag-reducing polymers to improve left ventricular hypertrophy and aortic remodeling in spontaneously hypertensive rats

    PubMed Central

    Zhang, Xinlu; Wang, Xu; Hu, Feng; Zhou, Boda; Chen, Hai-Bin; Zha, Daogang; Liu, Yili; Guo, Yansong; Zheng, Lemin; Xiu, Jiancheng

    2016-01-01

    Drag-reducing polymers (DRPs), when added in minute concentrations, have been shown to decrease peripheral vascular resistance. In this study, the effect of DRPs on the hypertension-induced left ventricular hypertrophy and aortic remodeling was evaluated in spontaneously hypertensive rats (SHR). Male SHR and age-matched Wistar rats were divided into four groups and received intravenous injection of normal saline (NS) or DRPs. Body weight (BW), heart rate (HR) and systolic blood pressure (SBP) were measured. Echocardiography was used to evaluate the changes in left ventricle (LV) function and global wall motion. The LV and aorta were stained by hematoxylin and eosin. Cell size of cardiomyocytes and aortic medial thickness were evaluated for each section. The expression of endothelin-1 (ET-1) of LV and aorta was examined by quantitative reverse transcription polymerase chain reaction (qRT-PCR) and immunohistochemistry. There was no significant difference in the increase of SBP among SHR + NS, SHR + 10DRP and SHR + 20DRP groups. SHR + NS group had markedly smaller left ventricular end-systolic diameter and left ventricular end-diastolic diameter but bigger anterior and posterior systolic wall thicknesses, while there was no significant difference in fractional shortening and ejection fraction. The cross-sectional areas (CSAs) of cardiomyocytes and the medial thickness of the aorta in SHR + 10 (ppm) DRP and SHR + 20 (ppm) DRP groups were significantly reduced compared with SHR + NS group. The expression of ET-1 in SHR + 10DRP and SHR + 20DRP groups was significantly attenuated. These results suggest that chronic treatment with DRPs can protect against left ventricular hypertrophy and aortic remodeling. DRPs may offer a new approach to the treatment of left ventricular hypertrophy and aortic remodeling caused by hypertension. PMID:28008249

  18. Entrance and exit wounds of high velocity bullet: An autopsy analysis in the event of dispersing the mass rally in Bangkok Thailand, May 2010.

    PubMed

    Peonim, Vichan; Srisont, Smith; Udnoon, Jitta; Wongwichai, Sompong; Thapon, Arisa; Worasuwannarak, Wisarn

    2016-11-01

    Fatal mass casualties by high velocity bullets (HVBs) are rare events in peaceful countries. This study presents 27 forensic autopsy cases with 32 shots fired by 5.56×45mm. HVB (M-16 rifle bullets) during the dispersing the mass rally in Bangkok Thailand, May 2010. It was found that twenty-three (71.88%) typical entrance HVB wounds had round sizes less than the bullet diameters. Most entrance wounds had microtears but no collar abrasion since a HVB has a small streamlined spitzer tip and full metal jacket. For exit wounds, there were various sizes and shapes depending on which section of wound ballistics presented when the bullet exited the body. If a bullet exited in the section of temporally cavity formation, there would be a large size exit wound in accordance with the degree of bullet yaw. This is different from civilian bullets whereby the shape looks like a cylindrical round nose and at low velocity that causes entrance wounds with a similar size to the bullet diameter and is usually round or oval shape with collar abrasion. The temporary cavity is not as large as in a HVB so exit wounds are not quite as large and present a ragged border compared to a HVB. We also reported 9 out of 32 shots (28.13%) of atypical entrance wounds that had various characteristics depending on site of injury and destabilization of bullets. These findings may be helpful to forensic pathologists and to give physicians, who need to diagnose HVB wounds, more confidence. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  19. Connector tube for a turbine rotor cooling circuit

    DOEpatents

    Li, Ming Cheng

    2003-06-24

    A tubular connector adapted to extend between two tubular components comprising a tubular body having an internal diameter, a first free end including an annular radial flange having a tapered surface adapted to engage a complementary seating surface on a first of the two tubular components, the internal diameter remaining constant through the first free end; and a second free end having an annular bulbous shape adapted to seat within a cylindrical end of a second of the two tubular components.

  20. Connector tube for a turbine rotor cooling circuit

    DOEpatents

    Li, Ming Cheng

    2002-01-01

    A tubular connector adapted to extend between two tubular components comprising a tubular body having an internal diameter, a first free end including an annular radial flange having a tapered surface adapted to engage a complementary seating surface on a first of the two tubular components, the internal diameter remaining constant through the first free end; and a second free end having an annular bulbous shape adapted to seat within a cylindrical end of a second of the two tubular components.

  1. Space shuttle: Aerodynamic characteristics of a 162-inch diameter solid rocket booster with and without strakes

    NASA Technical Reports Server (NTRS)

    Johnson, J. D.; Radford, W. D.; Rampy, J. M.

    1973-01-01

    Tests conducted at NASA-Langley have shown that a small flap or strake can generate a significant amount of lift on a circular cylinder with large cross flow. If strakes are placed on the opposite sides and ends on a circular body, a moment will be produced about the center of mass of the body. The purpose of this test was to determine the static-aerodynamic forces and moments of a 162-inch diameter SRB (PRR) with and without strakes. The total angle-of-attack range of the SRB test was from -10 to 190 degrees. Model roll angles were 0, 45, 90, and 135 degrees with some intermediate angles. The Mach range was from 0.6 to 3.48. The 0.00494 scale model was designated as MSFC No. 449.

  2. Prenatal development in fishers (Martes pennanti)

    USGS Publications Warehouse

    Frost, H.C.; Krohn, W.B.; Bezembluk, E.A.; Lott, R.; Wallace, C.R.

    2005-01-01

    We evaluated and quantified prenatal growth of fishers (Martes pennanti) using ultrasonography. Seven females gave birth to 21 kits. The first identifiable embryonic structures were seen 42 d prepartum; these appeared to be unimplanted blastocysts or gestational sacs, which subsequently implanted in the uterine horns. Maternal and fetal heart rates were monitored from first detection to birth. Maternal heart rates did not differ among sampling periods, while fetal hearts rates increased from first detection to birth. Head and body differentiation, visible limbs and skeletal ossification were visible by 30, 23 and 21 d prepartum, respectively. Mean diameter of gestational sacs and crown-rump lengths were linearly related to gestational age (P < 0.001). Biparietal and body diameters were also linearly related to gestational age (P < 0.001) and correctly predicted parturition dates within 1-2 d. ?? 2004 Elsevier Inc. All rights reserved.

  3. Focused ion beam source method and apparatus

    DOEpatents

    Pellin, Michael J.; Lykke, Keith R.; Lill, Thorsten B.

    2000-01-01

    A focused ion beam having a cross section of submicron diameter, a high ion current, and a narrow energy range is generated from a target comprised of particle source material by laser ablation. The method involves directing a laser beam having a cross section of critical diameter onto the target, producing a cloud of laser ablated particles having unique characteristics, and extracting and focusing a charged particle beam from the laser ablated cloud. The method is especially suited for producing focused ion beams for semiconductor device analysis and modification.

  4. Electrochemical system and method for electropolishing hollow metal bodies

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Taylor, E. Jennings; Inman, Maria E.; Hall, Timothy

    A method and system for electrochemically machining a hollow body of a metal or a metal alloy. An electrode is positioned within a hollow body including a metal or metal alloy, where the hollow body has a variable internal diameter. The hollow body is oriented vertically, with the electrode oriented vertically therein. The hollow body is at least partially filled with an aqueous, acidic electrolyte solution, the electrolyte solution being devoid of hydrofluoric acid and having a viscosity less than 15 cP. An electric current is passed between the hollow body and the electrode, where the electric current includes amore » plurality of anodic pulses and a plurality of cathodic pulses, and where the cathodic pulses are interposed between at least some of the anodic pulses.« less

  5. Usefulness of ultrasound examination in the evaluation of a neonate's body fluid status.

    PubMed

    Kieliszczyk, Joanna; Baranowski, Wojciech; Kosiak, Wojciech

    2016-06-01

    Appropriate hydration is a very important prognostic factor for the patient's health. Ultrasonographic assessment of hydration status is rarely used in pediatric medicine and it is not used at all in neonates due to the fact that no reference values have been established for this age group. The aim of the paper was to establish reference values for neonates. The study included 50 neonates from two hospitals in the Lower Silesia region of Poland; 25 of them were healthy patients (full-term newborns with no perinatal complications) and 25 were sick patients (newborns with heart defects such as ostium secundum atrial septal defect, ventricular septal defect, permanent foramen ovale and patent ductus arteriosus as well as newborns with neonatal jaundice or pneumonia that occurred during the first days of life). The ultrasound scans were conducted during the first days of the children's life. For every child inferior vena cava diameter was measured in the substernal area, longitudinal plane, M-mode in two respiratory phases: inhalation and exhalation. In addition, abdominal aorta diameter was determined (substernal area, transverse plane). The study demonstrated a statistically significant difference in the calculated inferior vena cava collapsibility index between both groups. Two other indices included the ratio of the inferior vena cava diameter during the expiratory phase to the diameter of the aorta and the ratio of the inferior vena cava diameter during the inspiratory phase to the diameter of the aorta; a statistically significant difference between both groups was found only for the measurements in the inspiratory phase. Based on the study results normal ranges for hydration indices in neonates were established. The need for the measurement of the abovementioned parameters in the inspiratory phase was determined. In addition, the usefulness of the ultrasound examination for the evaluation of body fluid status in this pediatric age group, particularly in preterm newborns, was noted due to its painless and non-invasive nature as well as easy access to equipment at neonatology wards.

  6. Glenoid version and size: does gender, ethnicity, or body size play a role?

    PubMed

    Piponov, Hristo Ivanov; Savin, David; Shah, Neal; Esposito, Domenic; Schwartz, Brian; Moretti, Vincent; Goldberg, Benjamin

    2016-11-01

    Variations in glenoid morphology among patients of different gender, body habitus, and ethnicity have been of interest for surgeons. Understanding these anatomical variations is a critical step in restoring normal glenohumeral structure during shoulder reconstruction surgery. Retrospective review of 108 patient shoulder CT scans was performed and glenoid version, AP diameter and height were measured. Statistical multiple regression models were used to investigate the ability of gender and ethnicity to predict glenoid AP diameter, height, and version independently of patient weight and height. The mean glenoid AP diameter was 24.7 ± 3.5, the mean glenoid height was 31.7 ± 3.7, and the mean glenoid version was 0.05 ± 9.05. According to our regression models, males would be expected to exhibit 8.4° more glenoid retroversion than females (p = 0.003) and have 2.9 mm larger glenoid height compared to females (p = 0.002). The predicted male glenoid AP diameter was 3.4 mm higher than that in females (p < 0.001). Hispanics demonstrated 6.4° more glenoid anteversion compared to African-Americans (p = 0.04). Asians exhibited 4.1 mm smaller glenoid AP diameters than African-Americans (p = 0.002). An increase of 25 kg in patient weight resulted in 1 mm increase in AP diameter (p = 0.01). Gender is the strongest independent predictor of glenoid size and version. Males exhibited a larger size and more retroverted glenoid. Patient height was found to be predictive of glenoid size only in patients of the same gender. Although variations in glenoid size and version are observed among ethnicities, larger sample size ethnic groups will be necessary to explore the precise relations. Surgeons should consider gender and ethnic variations in the pre-operative planning and surgical restoration of the native glenohumeral relationship. Anatomic Study.

  7. Analytical correlation of centrifugal compressor design geometry for maximum efficiency with specific speed

    NASA Technical Reports Server (NTRS)

    Galvas, M. R.

    1972-01-01

    Centrifugal compressor performance was examined analytically to determine optimum geometry for various applications as characterized by specific speed. Seven specific losses were calculated for various combinations of inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, blade exit backsweep, and inlet-tip absolute tangential velocity for solid body prewhirl. The losses considered were inlet guide vane loss, blade loading loss, skin friction loss, recirculation loss, disk friction loss, vaneless diffuser loss, and vaned diffuser loss. Maximum total efficiencies ranged from 0.497 to 0.868 for a specific speed range of 0.257 to 1.346. Curves of rotor exit absolute flow angle, inlet tip-exit diameter ratio, inlet hub-tip diameter ratio, head coefficient and blade exit backsweep are presented over a range of specific speeds for various inducer tip speeds to permit rapid selection of optimum compressor size and shape for a variety of applications.

  8. Experiment study of bio-tissue's temperature irradiated by laser based on optical fiber F-P sensor

    NASA Astrophysics Data System (ADS)

    Shan, Ning; Liu, Xia

    2014-08-01

    Laser has several advantages, such as strong anti-interference ability, quick speed, high power, agility and precision. It is widely applied in military and medicine fields. When laser acts on human body, biological tissue of human body will appear the phenomenon of ablation and carbonization and solidification. In order to effectively defend excess damage by laser, the thermal effect research of skin tissue should be carried out. Temperature is a key parameter in the processing between laser and bio-tissue. It is the mostly foundation using analyze size of thermal damage area and forecast thermal damage degree. In this paper, the low fineness optical fiber F-P sensing system for temperature measurement is designed and established. The real-time measurement system of temperature generated by laser irradiating bio-tissue is build based on the sensing system. The temperature distributing generated by laser in the bio-tissue is studied through experiment when the spot diameter of emission laser is difference with the same energy density and the energy density is difference with the same spot diameter of emission laser. The experimental results show that the sensing system can be used to the real-time temperature measurement of bio-tissue efficiency. It has small bulk. Its outer diameter is 250μm. And the hurt for bio-tissue is small. It has high respond speed. The respond time of temperature is less than 1s. These can be satisfied with practice demand. When the energy density of laser is same, the temperature rising in the same location is low along the spot diameter of emission laser increasing. When the spot diameter of emission laser is same, the temperature rising in the same location is increasing along with the energy density of laser increasing.

  9. Microvascular responses to body tilt in cutaneous maximus muscle of conscious rats

    NASA Technical Reports Server (NTRS)

    Puri, Rohit K.; Segal, Steven S.

    1994-01-01

    We investigated microvascular responses to head-up tilt (HUT) and head-down tilt (HDT) in striated muscle of conscious male rats. To observe the microcirculation in the cutaneous maximus muscle, a transparent polycarbonate chamber was implanted aseptically into a skin fold created between the shoulders. Rats were trained to sit quietly during HUT and HDT while positioned on a horizontal microscope that rotated in the sagittal plane. At 4-5 days after surgery, arteriole and venule diameters were recorded using videomicroscopy while the rat experienced 10 min each (in random order) of HUT or HDT at 20 deg or 40 deg separated by 2-h rest periods. HUT had no affect on microvessel diameter; 20 deg HDT had little affect. In response to 40 deg HDT, 'large' arterioles constricted by 18 +/- 2% and 'small' arterioles dilated by 21 +/- 3%; this difference suggested variation in mechanisms controlling arteriolar responses. Venules exhibited a larger fluctuation in diameter during 40 deg HDT compared with other body positions, suggesting that venomotor activity may be induced with sufficient fluid shift or change in central venous pressure. These observations illustrate a viable model for studying microvascular responses to gravitational stress in conscious rats.

  10. Degenerative lumbar spinal stenosis and lumbar spine configuration

    PubMed Central

    Hamoud, K.; May, H.; Hay, O.; Medlej, B.; Masharawi, Y.; Peled, N.; Hershkovitz, I.

    2010-01-01

    As life expectancy increases, degenerative lumbar spinal stenosis (DLSS) becomes a common health problem among the elderly. DLSS is usually caused by degenerative changes in bony and/or soft tissue elements. The poor correlation between radiological manifestations and the clinical picture emphasizes the fact that more studies are required to determine the natural course of this syndrome. Our aim was to reveal the association between lower lumbar spine configuration and DLSS. Two groups were studied: the first included 67 individuals with DLSS (mean age 66 ± 10) and the second 100 individuals (mean age 63.4 ± 13) without DLSS-related symptoms. Both groups underwent CT images (Philips Brilliance 64) and the following measurements were performed: a cross-section area of the dural sac, vertebral body dimensions (height, length and width), AP diameter of the bony spinal canal, lumbar lordosis and sacral slope angles. All measurements were taken at L3 to S1. Vertebral body lengths were significantly greater in the DLSS group at all levels compared to the control, whereas anterior vertebral body heights (L3, L4, L5) and middle vertebral heights (L3, L5) were significantly smaller in the LSS group. Lumbar lordosis, sacral slope and bony spinal canal were significantly smaller in the DLSS compared to the control. We conclude that the size and shape of vertebral bodies and canals significantly differed between the study groups. A tentative model is suggested to explain the association between these characteristics and the development of degenerative spinal stenosis. PMID:20652366

  11. High field solenoids for muon cooling

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Green, M.A.; Eyssa, Y.; Kenny, S.

    1999-09-08

    The proposed cooling system for the muon collider will consist of a 200 meter long line of alternating field straight solenoids interspersed with bent solenoids. The muons are cooled in all directions using a 400 mm long section liquid hydrogen at high field. The muons are accelerated in the forward direction by about 900 mm long, 805 MHz RF cavities in a gradient field that goes from 6 T to -6 T in about 300 mm. The high field section in the channel starts out at an induction of about 2 T in the hydrogen. As the muons proceed downmore » the cooling channel, the induction in the liquid hydrogen section increases to inductions as high as 30 T. The diameter of the liquid hydrogen section starts at 750 mm when the induction is 2 T. As the induction in the cooling section goes up, the diameter of the liquid hydrogen section decreases. When the high field induction is 30 T, the diameter of the liquid hydrogen section is about 80 mm. When the high field solenoid induction is below 8.5 T or 9T, niobium titanium coils are proposed for generating .the magnetic field. Above 8.5 T or 9 T to about 20 T, graded niobium tin and niobium titanium coils would be used at temperatures down to 1.8 K. Above 20 T, a graded bybrid magnet system is proposed, where the high field magnet section (above 20 T) is either a conventional water cooled coil section or a water cooled Bitter type coil. Two types of superconducting coils have been studied. They include; epoxy impregnated intrinsically stable coils, and cable in conduit conductor (CICC) coils with helium in the conduit.« less

  12. Pediatric autopsy case of asphyxia due to salmon egg (ikura) aspiration.

    PubMed

    Takamiya, Masataka; Niitsu, Hisae; Saigusa, Kiyoshi; Dewa, Koji

    2016-09-01

    Here we report an autopsy case of asphyxia due to aspiration of a salmon egg (ikura) into the airway. The patient was a 19-month-old girl. During breakfast, she put salmon eggs into her mouth, and began to walk. She slipped, fell down, and collapsed. She was pronounced dead following 2 h of resuscitation. The body was autopsied 28 h after death. The gastric contents consisted of rice, orange sections, and white salmon eggs. The lungs were deeply congested and over-inflated. In the right lung, areas of atelectasis in the upper and middle lobes were seen. A yellow salmon egg (8 mm in diameter) was found in the trachea. Although fish eggs are consumed throughout the world, reports of this sort are limited. The aspiration of fish eggs is under-acknowledged and underreported. The importance of preventive measures needs to be emphasized to parents and caregivers. © 2016 Japan Pediatric Society.

  13. Generational changes in the growth of children from Maribor and Slovenia.

    PubMed

    Bigec, Martin

    2013-05-01

    Among the numerous factors which influence a child's growth and development are also factors of changeable socio-economic environment and life style. Our aim was to evaluate these changes and contribute to preventive measures and evaluation of a child's growth in pediatric practice. Therefore, we decided to estimate the state of body growth in two generations of children from Maribor at five and six years of age of both gender, establish secular changes and define standards. On a representative sample (gender and age) of 1461 children from Maribor measured in 1996 and a sample of 608 children from Maribor, measured in 1966, 28 body features were studied and compared in each population unit. Variables were statistically and epidemiologically assessed and results were controlled by a test. The following anthropometric differences were significant: in 5-year old boys the measures in the 1996 generation are statistically higher than in 1966 - foot length, head length, upper arm skinfold, subscapular skinfold, arm length, arm diameter, upper thigh skinfold, stature (length), suprailiac skinfold, and body weight. Decreased measures are: abdomen circumference, knee circumference, sitting height, elbow circumference, biacromial diameter, and face heigth. In 6-year old boys additional features have increased in comparison with the year 1966: sternal height, tight circumference, hip width, chest circumference; following measures have decreased: face height, head circumference. In 5-year old girls: increased measures in comparison with the generation from 1966 are: lower leg length, head length, ankle circumference, upper arm skinfold, body weight, billiac diameter, body height, subscapular skinfold, chest circumference, hip circumference, sternal height, suprailiac skinfold, decreased measures are: head circumference, elbow circumference, face circumference, shoulder with, sitting height. In 6-year old girls additional measures are increased: wrist circumference, arm length and chest circumference. Changing trends show an increased tendency towards decrease or increase of most body measurements. In everyday practice the most commonly used measurements are: body mass, head circumference, body length in babies and body height in pre-school children. Our measurements proved, with a p-value of 0.001, that measurements of children in 1966, also shown in diagrams, are significantly different from measurements in 1996. In the second part of this paper we present a part of the anthropometric measurement study carried out for the standardization of the DENVER II developmental screening test. There were 1596 healthy Slovene children between zero and six and half years of age included into the observation. Children come from Maribor, Koper, Velenje and Ljubljana. We used the Cameron's measurement and statistical method. Diagrams were made for following body measures: body mass, body height, head circumference, upper arm circumference, thigh circumference and body mass index. A comparative analysis with the Euro-Growth study showed that our results correspond with the European standards. Therefore, our results are suggested to be applied in everyday pediatric practice.

  14. Effect of body repositioning after venous air embolism. An echocardiographic study

    NASA Technical Reports Server (NTRS)

    Geissler, H. J.; Allen, S. J.; Mehlhorn, U.; Davis, K. L.; Morris, W. P.; Butler, B. D.

    1997-01-01

    BACKGROUND: Current therapy for massive venous air embolism (VAE) may include the use of the left lateral recumbent (LLR) position, although its effectiveness has been questioned. This study used transesophageal echocardiography to evaluate the effect of body repositioning on intracardiac air and acute cardiac dimension changes. METHODS: Eighteen anesthetized dogs in the supine position received a venous air injection of 2.5 ml/kg at a rate of 5 ml/ s. After 1 min the dogs were repositioned into either the LLR, LLR 10 degrees head down (LLR-10 degrees), right lateral recumbence, or remained in the supine position. RESULTS: Repositioning after VAE resulted in relocation of intracardiac air to nondependent areas of the right heart. Peak right ventricular (RV) diameter increase and mean arterial pressure decrease were greater in the repositioned animals compared with those in the supine position (P < 0.05). Right ventricular diameter and mean arterial pressure showed an inverse correlation (r = 0.81). Peak left atrial diameter decrease was greater in the LLR and LLR-10 degrees positions compared with the supine position (P < 0.05). Repositioning did not influence peak pulmonary artery pressure increase, and no correlation was found between RV diameter and pulmonary artery pressure. All animals showed electrocardiogram and echocardiographic changes reconcilable with myocardial ischemia. CONCLUSIONS: In dogs, body repositioning after VAE provided no benefit in hemodynamic performance or cardiac dimension changes, although relocation of intracardiac air was demonstrated. Right ventricular air did not appear to result in significant RV outflow obstruction, as pulmonary artery pressure increased uniformly in all groups and was not influenced by the relocation of intracardiac air. The combination of increased RV afterload and arterial hypotension, possibly with subsequent RV ischemia rather than RV outflow obstruction by an airlock appeared to be the primary mechanism for cardiac dysfunction after VAE.

  15. Collisional Processing of Olivine and Pyroxene in Cometary Dust

    NASA Technical Reports Server (NTRS)

    Lederer, S. M.; Cintala, M. J.; Olney, R. D.; Keller, L. P.; Nakamura-Messenger, K.; Zolensky, M.

    2008-01-01

    According to the nebular theory of solar-system formation, collisions between bodies occurred frequently early in the solar system s history and continue at a lower rate even today. Collisions have reworked the surface compositions and structures of cometary nuclei, though to an unknown degree. The majority of the collisional history of a typical Jupiter-family comet takes place while it resides in the Kuiper Belt. Impacts occur on the surfaces of small bodies over a large range of velocities by impactors of all sizes, but typical encounter speeds within the Kuiper Belt are 1.5 to 2.0 km/s[1]. Durda and Stern suggest that the interiors of most cometary nuclei with diameters <5 km have been heavily damaged by collisions [2]. They estimate that over a period of 3.5 Gy, a nucleus with a diameter of 2 km and an orbit between 35-45 AU will experience 90-300 collisions with objects greater than 8 m in diameter. In this same time interval, collisions between a typical Trans-Neptunian Object (TNO) 200 km in diameter and objects with d > 8 m would rework up to one-third of that TNO s surface. In fact, it has been proposed that most short-period comets from the Kuiper Belt (90%) are collisional fragments from larger TNOs - not primordial objects themselves [3] - and that most short-period comets from the Kuiper Belt will be collisionally processed both on their surfaces as well as in their interiors.

  16. Ultra-minimally invasive local immune cell therapy and regenerative therapy by multi-piercing surgery for abdominal solid tumor: therapeutic simulation by natural orifice translumenal endoscopic surgery-assisted needlescopic surgery using 3-mm diameter robots.

    PubMed

    Ohdaira, Takeshi; Tsutsumi, Norifumi; Xu, Hao; Mori, Megumu; Uemura, Munenori; Ieiri, Satoshi; Hashizume, Makoto

    2011-07-01

    We have invented multi-piercing surgery (MPS) which could potentially solve the triangular formation loss and device clashing which occur in single-port surgery (SPS), as well as restricted visual field, organ damage by needle-type instruments, and impaired removal of a resected organ from the body which occur in needlescopic surgery (NS). MPS is natural orifice translumenal endoscopic surgery (NOTES)-assisted NS. We used 3-mm diameter robots as needle-type instruments for MPS to examine the possibility of local immune cell therapy and regenerative therapy using stem cells for pancreatic cancer. In MPS using two robots, the therapeutic cell suspension was injected into a target region of pancreas in two pigs. Both retention of a capsule of liquid cell suspension and invasive level were evaluated. Triangular formation could be ensured. The use of small-diameter robots allowed (1) the surgical separation of the pancreas and the retroperitoneum, and (2) the formation of the capsule containing the immune cell and stem cell suspension. The endoscope for NOTES provided a clear visual field and also assisted the removal of a resected organ from the body. The visual field of the endoscope could be oriented well by using an electromagnetic navigation system. MPS using small-diameter robots could potentially solve the issues inherent in SPS and NS and could allow minimally invasive local immune cell and stem cell therapy.

  17. Quantification of human upper extremity nerves and fascicular anatomy.

    PubMed

    Brill, Natalie A; Tyler, Dustin J

    2017-09-01

    In this study we provide detailed quantification of upper extremity nerve and fascicular anatomy. The purpose is to provide values and trends in neural features useful for clinical applications and neural interface device design. Nerve cross-sections were taken from 4 ulnar, 4 median, and 3 radial nerves from 5 arms of 3 human cadavers. Quantified nerve features included cross-sectional area, minor diameter, and major diameter. Fascicular features analyzed included count, perimeter, area, and position. Mean fascicular diameters were 0.57 ± 0.39, 0.6 ± 0.3, 0.5 ± 0.26 mm in the upper arm and 0.38 ± 0.18, 0.47 ± 0.18, 0.4 ± 0.27 mm in the forearm of ulnar, median, and radial nerves, respectively. Mean fascicular diameters were inversely proportional to fascicle count. Detailed quantitative anatomy of upper extremity nerves is a resource for design of neural electrodes, guidance in extraneural procedures, and improved neurosurgical planning. Muscle Nerve 56: 463-471, 2017. © 2016 Wiley Periodicals, Inc.

  18. Superconductive wire

    DOEpatents

    Korzekwa, David A.; Bingert, John F.; Peterson, Dean E.; Sheinberg, Haskell

    1995-01-01

    A superconductive article is made by inserting a rigid mandrel into an internal cavity of a first metallic tube, said tube having an interior surface and an exterior surface, said interior surface defining the interior cavity, forming a layer of a superconductive material or superconductive precursor upon the exterior surface of said first metallic tube, machining the layer of superconductive material or superconductive precursor to a predetermined diameter to form an intermediate article configured for insertion into a second metallic tube having an interior diameter corresponding to the predetermined diameter, inserting the machined intermediate article into a second metallic tube having an internal diameter corresponding to the predetermined diameter of the intermediate article to form a composite intermediate article, reducing or ironing the composite intermediate article to a predetermined cross-sectional diameter, and sintering the reduced or ironed composite intermediate article at temperatures and for time sufficient for the superconductive material or superconductive precursor to exhibit superconductivity.

  19. Superconductive wire

    DOEpatents

    Korzekwa, D.A.; Bingert, J.F.; Peterson, D.E.; Sheinberg, H.

    1995-07-18

    A superconductive article is made by inserting a rigid mandrel into an internal cavity of a first metallic tube, said tube having an interior surface and an exterior surface, said interior surface defining the interior cavity, forming a layer of a superconductive material or superconductive precursor upon the exterior surface of said first metallic tube, machining the layer of superconductive material or superconductive precursor to a predetermined diameter to form an intermediate article configured for insertion into a second metallic tube having an interior diameter corresponding to the predetermined diameter, inserting the machined intermediate article into a second metallic tube having an internal diameter corresponding to the predetermined diameter of the intermediate article to form a composite intermediate article, reducing or ironing the composite intermediate article to a predetermined cross-sectional diameter, and sintering the reduced or ironed composite intermediate article at temperatures and for time sufficient for the superconductive material or superconductive precursor to exhibit superconductivity. 2 figs.

  20. Role of anthropometric data in the prediction of 4-stranded hamstring graft size in anterior cruciate ligament reconstruction.

    PubMed

    Ho, Sean Wei Loong; Tan, Teong Jin Lester; Lee, Keng Thiam

    2016-03-01

    To evaluate whether pre-operative anthropometric data can predict the optimal diameter and length of hamstring tendon autograft for anterior cruciate ligament (ACL) reconstruction. This was a cohort study that involved 169 patients who underwent single-bundle ACL reconstruction (single surgeon) with 4-stranded MM Gracilis and MM Semi-Tendinosus autografts. Height, weight, body mass index (BMI), gender, race, age and -smoking status were recorded pre-operatively. Intra-operatively, the diameter and functional length of the 4-stranded autograft was recorded. Multiple regression analysis was used to determine the relationship between the anthropometric measurements and the length and diameter of the implanted autografts. The strongest correlation between 4-stranded hamstring autograft diameter was height and weight. This correlation was stronger in females than males. BMI had a moderate correlation with the diameter of the graft in females. Females had a significantly smaller graft both in diameter and length when compared with males. Linear regression models did not show any significant correlation between hamstring autograft length with height and weight (p>0.05). Simple regression analysis demonstrated that height and weight can be used to predict hamstring graft diameter. The following regression equation was obtained for females: Graft diameter=0.012+0.034*Height+0.026*Weight (R2=0.358, p=0.004) The following regression equation was obtained for males: Graft diameter=5.130+0.012*Height+0.007*Weight (R2=0.086, p=0.002). Pre-operative anthropometric data has a positive correlation with the diameter of 4 stranded hamstring autografts but no significant correlation with the length. This data can be utilised to predict the autograft diameter and may be useful for pre-operative planning and patient counseling for graft selection.

  1. Ultrasonographic reproductive tract measures and pelvis measures as predictors of pregnancy failure and anestrus in restricted bred beef heifers.

    PubMed

    Holm, Dietmar E; Nielen, Mirjam; Jorritsma, Ruurd; Irons, Peter C; Thompson, Peter N

    2016-02-01

    Previous reports have shown that reproductive tract score (RTS) can predict reproduction outcomes in seasonally bred beef heifers, although the accuracy can vary. Some ultrasonographic measures of the female reproductive tract and pelvis area have also been associated with reproductive outcome in young heifers. The objectives of this study were to determine which transrectal ultrasound or pelvis measures taken at a single examination are independent predictors of reproductive failure and whether the RTS system can be optimized with this information. In this observational study, year-old beef heifers (n = 488) in 2 birth cohorts were followed from just before the first breeding until confirmation of pregnancy. A single pre-breeding examination included body condition score, RTS, ultrasound measures of the reproductive tract (length and diameter of the left and right ovaries, presence and diameter of a CL, largest follicle diameter and left uterus horn diameter) and transverse and vertical diameters of the pelvis. Additional farm records including dam parity, sire, birth weight and birth date, weaning weight, weaning date, prebreeding body weight, AI dates, and semen used were available. Breeding consisted of 50 days of AI, followed 5 to 7 days later by a 42-day bull breeding period. Pregnancy failure was defined as the failure to become pregnant after the AI and bull breeding periods, while anestrus was defined as the failure to be detected in estrus during the 50-day AI period. From the prebreeding data and farm records, independent predictors of pregnancy failure and anestrus were identified using stepwise reduction in multiple logistic regression models. Age at the onset of breeding was the only consistent independent predictor of pregnancy failure and anestrus in both cohorts of this study (P < 0.05). Body condition score, uterus horn diameter, absence of a CL, largest follicle of less than 13 mm, and pelvis area (PA) were the prebreeding examination variables that remained in prognostic models (P < 0.1). Combining either the model based on the 3 remaining ultrasound measures or RTS with PA provided more accurate prognostic models for pregnancy failure and anestrus than using RTS alone (P < 0.05). It is concluded that ultrasound measures have prognostic value for pregnancy failure in restricted bred yearling heifers as a result of their association with anestrus, and that smaller PA has additional prognostic value for poorly performing heifers. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. The accuracy of body mass prediction for elderly specimens: Implications for paleoanthropology and legal medicine.

    PubMed

    Chevalier, Tony; Lefèvre, Philippe; Clarys, Jan Pieter; Beauthier, Jean-Pol

    2016-10-01

    Different practices in paleoanthropology and legal medicine raise questions concerning the robustness of body mass (BM) prediction. Integrating personal identification from body mass estimation with skeleton is not a classic approach in legal medicine. The originality of our study is the use of an elderly sample in order to push prediction methods to their limits and to discuss about implications in paleoanthropology and legal medicine. The aim is to observe the accuracy of BM prediction in relation to the body mass index (BMI, index of classification) using five femoral head (FH) methods and one shaft (FSH) method. The sample is composed of 41 dry femurs obtained from dissection where age (c. 82 years) and gender are known, and weight (c. 59.5 kg) and height are measured upon admission to the body leg service. We show that the estimation of the mean BM of the elderly sample is not significantly different to the real mean BM when the appropriate formula is used for the femoral head diameter. In fact, the best prediction is obtained with the McHenry formula (1992), which was based on a sample with an equivalent average mass to that of our sample. In comparison, external shaft diameters, which are known to be more influenced by mechanical stimuli than femoral head diameters, yield less satisfactory results with the McHenry formula (1992) for shaft diameters. Based on all the methods used and the distinctive selected sample, overestimation (always observed with the different femoral head methods) can be restricted to 1.1%. The observed overestimation with the shaft method can be restricted to 7%. However, the estimation of individual BM is much less reliable. The BMI has a strong impact on the accuracy of individual BM prediction, and is unquestionably more reliable for individuals with normal BMI (9.6% vs 16.7% for the best prediction error). In this case, the FH method is also the better predictive method but not if we integrate the total sample (i.e., the FSH method is better with more varied BMI). Finally, the estimation of the mean BM of a sample can be used with more confidence compared to the estimation of individual BM. The former is very useful in an evolutionary perspective whereas the latter should be used in keeping with the information gathered on the studied specimen in order to reduce prediction errors. Finally, the BM estimation can be a parameter to consider for personal identification. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  3. Effect of hole geometry and Electric-Discharge Machining (EDM) on airflow rates through small diameter holes in turbine blade material

    NASA Technical Reports Server (NTRS)

    Hippensteele, S. A.; Cochran, R. P.

    1980-01-01

    The effects of two design parameters, electrode diameter and hole angle, and two machine parameters, electrode current and current-on time, on air flow rates through small-diameter (0.257 to 0.462 mm) electric-discharge-machined holes were measured. The holes were machined individually in rows of 14 each through 1.6 mm thick IN-100 strips. The data showed linear increase in air flow rate with increases in electrode cross sectional area and current-on time and little change with changes in hole angle and electrode current. The average flow-rate deviation (from the mean flow rate for a given row) decreased linearly with electrode diameter and increased with hole angle. Burn time and finished hole diameter were also measured.

  4. Saddle clamp assembly

    NASA Technical Reports Server (NTRS)

    Belrose, Charles R. (Inventor)

    1994-01-01

    A saddle clamp assembly is presented. The assembly is comprised of a hollow cylindrical body centered about a longitudinal axis and being diametrically split into semicircular top and bottom sections. Each section has a pair of connection flanges, at opposite ends, that project radially outward. A pair of bolts are retained on the top section flanges and are threadable into nuts retained on the bottom section flanges. A base member is anchored to a central underside portion of the bottom clamp body section and has a pair of connection tabs positioned beneath the bottom clamp body section connection flanges on opposite sides of the clamp axis. A pair of bolts are retained on the base member connection tabs and are threadable into a pair of nuts retainable on a support structure. The connection tab and connection flanges on each side of the clamp body are axially offset in a manner permitting downward installation/removable tool access to the lower bolts past the connection flanges. An elongated retention tether is used to connect the top clamp body section to the balance of the clamp assembly. This prevents loss of the top clamp body section when it is removed from the bottom clamp body section.

  5. Free-Flight Test of a Technique for Inflating an NASA 12-Foot-Diameter Sphere at High Altitudes

    NASA Technical Reports Server (NTRS)

    Kehlet, Alan B.; Patterson, Herbert G.

    1959-01-01

    A free-flight test has been conducted to check a technique for inflating an NASA 12-foot-diameter inflatable sphere at high altitudes. Flight records indicated that the nose section was successfully separated from the booster rocket, that the sphere was ejected, and that the nose section was jettisoned from the fully inflated sphere. On the basis of preflight and flight records, it is believed that the sphere was fully inflated by the time of peak altitude (239,000 feet). Calculations showed that during descent, jettison of the nose section occurred above an altitude of 150,000 feet. The inflatable sphere was estimated to start to deform during descent at an altitude of about 120,000 feet.

  6. Reference range of fetal transverse cerebellar diameter between 18 and 24 weeks of pregnancy in a Brazilian population.

    PubMed

    Araujo Júnior, Edward; Martins, Wellington P; Nardozza, Luciano Marcondes Machado; Pires, Claudio Rodrigues; Filho, Sebastião Marques Zanforlin

    2015-02-01

    To determine a reference range of fetal transverse cerebellar diameter in Brazilian population. This was a retrospective cross-sectional study with 3772 normal singleton pregnancies between 18 and 24 weeks of pregnancy. The transverse cerebellar diameter was measured on the axial plane of the fetal head at the level of the lateral ventricles, including the thalamus, cavum septum pellucidum, and third ventricle. To assess the correlation between transverse cerebellar diameter and gestational age, polynomial equations were calculated, with adjustments by the determination coefficient (R2). The mean of fetal transverse cerebellar diameter ranged from 18.49 ± 1.24 mm at 18 weeks to 25.86 ± 1.66 mm at 24 weeks of pregnancy. We observed a good correlation between transverse cerebellar diameter and gestational age, which was best represented by a linear equation: transverse cerebellar diameter: -6.21 + 1.307*gestational age (R2 = 0.707). We determined a reference range of fetal transverse cerebellar diameter for the second trimester of pregnancy in Brazilian population. © The Author(s) 2014.

  7. Near Earth asteroid orbit perturbation and fragmentation

    NASA Technical Reports Server (NTRS)

    Ahrens, Thomas J.; Harris, Alan W.

    1992-01-01

    Collisions by near earth asteroids or the nuclei of comets pose varying levels of threat to man. A relatively small object, approximately 100 meter diameter, which might be found on an impact trajectory with a populated region of the Earth, could potentially be diverted from an Earth impacting trajectory by mass driver rocket systems. For larger bodies, such systems would appear to be beyond current technology. For any size object, nuclear explosions appear to be more efficient, using either the prompt blow-off from neutron radiation, the impulse from ejecta of near-surface explosion for deflection, or as a fragmenting charge. Practical deflections of bodies with diameters of 0.1, 1, and 10 km require interception, years to decades prior to earth encounter, with explosions a few kilotons, megatons, or gigatons, respectively, of equivalent TNT energy to achieve orbital velocity changes or destruction to a level where fragments are dispersed to harmless spatial densities.

  8. An investigation to determine the pressure distribution on the 0.0137 scale solid rocket booster forebody (MSFC model 467) at angles of attack at or near 90 deg and high Reynolds numbers in the MSFC High Reynolds Number Wind Tunnel (SA29F)

    NASA Technical Reports Server (NTRS)

    Ramsey, P. E.

    1976-01-01

    An aerodynamic investigation was conducted in the MSFC High Reynolds Number Wind Tunnel to determine the pressure distribution over the foresection of the current 146 inch diameter shuttle SRB. The test model consisted of a 0.0137 scale version of the SRB nose cone and a forward portion of the cylindrical body which was approximately 2.7 calibers in length. The pressure distributions are plotted as a function of longitudinal station ratioed to body diameter and circumferential location for each angle of attack and Mach number. A Reynolds number variation study was made for Mach numbers of 0.4 and 0.6 at an angle of attack of 270 deg and roll angle of 180 deg.

  9. MR imaging detection of cerebral microbleeds: effect of susceptibility-weighted imaging, section thickness, and field strength.

    PubMed

    Nandigam, R N K; Viswanathan, A; Delgado, P; Skehan, M E; Smith, E E; Rosand, J; Greenberg, S M; Dickerson, B C

    2009-02-01

    The emergence of cerebral microbleeds (CMB) as common MR imaging findings raises the question of how MR imaging parameters influence CMB detection. To evaluate the effects of modified gradient recalled-echo (GRE) MR imaging methods, we performed an analysis of sequence, section thickness, and field strength on CMB imaging properties and detection in subjects with cerebral amyloid angiopathy (CAA), a condition associated with microhemorrhage. Multiple MR images were obtained from subjects with probable CAA, with varying sequences (GRE versus susceptibility-weighted imaging [SWI]), section thicknesses (1.2-1.5 versus 5 mm), and magnetic field strengths (1.5T versus 3T). Individual CMB were manually identified and analyzed for contrast index (lesion intensity normalized to normal-appearing white matter signal intensity) and diameter. CMB counts were compared between 1.5T thick-section GRE and thin-section SWI for 3 subjects who underwent both protocols in the same scanning session. With other parameters constant, use of SWI, thinner sections, and a higher field strength yielded medium-to-large gains in CMB contrast index (CI; Cohen d 0.71-1.87). SWI was also associated with small increases in CMB diameter (Cohen d <0.3). Conventional thick-section GRE identified only 33% of CMB (103 of 310) seen on thin-section SWI. Lesions prospectively identified on GRE had significantly greater CI and diameter measured on the GRE image than those not prospectively identified. The examined alternatives to conventional GRE MR imaging yield substantially improved CMB contrast and sensitivity for detection. Future studies based on these techniques will most likely yield even higher prevalence estimates for CMB.

  10. MR Imaging Detection of Cerebral Microbleeds: Effect of Susceptibility-Weighted Imaging, Section Thickness, and Field Strength

    PubMed Central

    Nandigam, R.N.K.; Viswanathan, A.; Delgado, P.; Skehan, M.E.; Smith, E.E.; Rosand, J.; Greenberg, S.M.; Dickerson, B.C.

    2009-01-01

    BACKGROUND AND PURPOSE: The emergence of cerebral microbleeds (CMB) as common MR imaging findings raises the question of how MR imaging parameters influence CMB detection. To evaluate the effects of modified gradient recalled-echo (GRE) MR imaging methods, we performed an analysis of sequence, section thickness, and field strength on CMB imaging properties and detection in subjects with cerebral amyloid angiopathy (CAA), a condition associated with microhemorrhage. MATERIALS AND METHODS: Multiple MR images were obtained from subjects with probable CAA, with varying sequences (GRE versus susceptibility-weighted imaging [SWI]), section thicknesses (1.2–1.5 versus 5 mm), and magnetic field strengths (1.5T versus 3T). Individual CMB were manually identified and analyzed for contrast index (lesion intensity normalized to normal-appearing white matter signal intensity) and diameter. CMB counts were compared between 1.5T thick-section GRE and thin-section SWI for 3 subjects who underwent both protocols in the same scanning session. RESULTS: With other parameters constant, use of SWI, thinner sections, and a higher field strength yielded medium-to-large gains in CMB contrast index (CI; Cohen d 0.71–1.87). SWI was also associated with small increases in CMB diameter (Cohen d <0.3). Conventional thick-section GRE identified only 33% of CMB (103 of 310) seen on thin-section SWI. Lesions prospectively identified on GRE had significantly greater CI and diameter measured on the GRE image than those not prospectively identified. CONCLUSIONS: The examined alternatives to conventional GRE MR imaging yield substantially improved CMB contrast and sensitivity for detection. Future studies based on these techniques will most likely yield even higher prevalence estimates for CMB. PMID:19001544

  11. Hepatic steatosis in overweight/obese females: New screening method for those at risk

    PubMed Central

    Tarantino, Giovanni; Pizza, Genoveffa; Colao, Annamaria; Pasanisi, Fabrizio; Conca, Paolo; Colicchio, Patrizia; Finelli, Carmine; Contaldo, Franco; Di Somma, Carolina; Savastano, Silvia

    2009-01-01

    AIM: To identify which parameters could help to distinguish the “metabolically benign obesity”, which is not accompanied by insulin resistance (IR) and early atherosclerosis. METHODS: Eighty two of 124 overweight/obese females formed the study population, which was divided into two groups (52 and 30 subjects, respectively) with and without IR according to a HO meostatic Metabolic Assessment (HOMA) cut-off of 2, and were studied in a cross-sectional manner. The main outcome measures were waist circumference, serum uric acid, high-density lipoprotein-cholesterol and triglycerides, alanine aminotransferase, blood pressure and the two imaging parameters, hepatic steatosis and longitudinal diameter of the spleen, which were measured in relation to the presence/absence of IR. RESULTS: A variable grade of visceral obesity was observed in all subjects with the exception of three. Obesity of a severe grade was represented more in the group of IR individuals (P = 0.01). Hepatic steatosis, revealed at ultrasound, was more pronounced in IR than in non-IR subjects (P = 0.005). The two groups also demonstrated a clear difference in longitudinal spleen diameter and blood pressure, with raised and significant values in the IR group. Metabolic syndrome was frequent in the IR group, and was not modified when adjusted for menopause (P = 0.001). At linear regression, the β values of waist circumference and body mass index predicting HOMA were 0.295, P = 0.007 and 0.41, P = 0.0001, respectively. Measures of spleen longitudinal diameter were well predicted by body mass index (BMI) values, β = 0.35, P = 0.01, and by HOMA, β = 0.41, P = 0.0001. Blood pressure was predicted by HOMA values, β = 0.39, P = 0.0001). HOMA and hepatic steatosis were highly associated (rho = 0.34, P = 0.002). Interestingly, IR patients were almost twice as likely to have hepatic steatosis as non-IR patients. Among the MS criteria, blood pressure was very accurate in identifying the presence of IR (AUROC for systolic blood pressure 0.66, cut-off 125 mm of Hg, sensibility 64%, specificity 75%; AUROC for diastolic blood pressure 0.70, cut-off 85 mm of Hg, sensibility 54.5%, specificity 75%). CONCLUSION: As health care costs are skyrocketing, reliable and mainly inexpensive tools are advisable to better define subjects who really need to lose weight. PMID:19960566

  12. Free-living spirochetes from Cape Cod microbial mats detected by electron microscopy

    NASA Technical Reports Server (NTRS)

    Teal, T. H.; Chapman, M.; Guillemette, T.; Margulis, L.

    1996-01-01

    Spirochetes from microbial mats and anaerobic mud samples collected in salt marshes were studied by light microscopy, whole mount and thin section transmission electron microscopy. Enriched in cellobiose-rifampin medium, selective for Spirochaeta bajacaliforniensis, seven distinguishable spirochete morphotypes were observed. Their diameters ranged from 0.17 micron to > 0.45 micron. Six of these morphotypes came from southwest Cape Cod, Massachusetts: five from Microcoleus-dominated mat samples collected at Sippewissett salt marsh and one from anoxic mud collected at School Street salt marsh (on the east side of Eel Pond). The seventh morphotype was enriched from anoxic mud sampled from the north central Cape Cod, at the Sandy Neck salt marsh. Five of these morphotypes are similar or identical to previously described spirochetes (Leptospira, Spirochaeta halophila, Spirochaeta bajacaliforniensis, Spirosymplokos deltaeiberi and Treponema), whereas the other two have unique features that suggest they have not been previously described. One of the morphotypes resembles Spirosymplokos deltaeiberi (the largest free-living spirochete described), in its large variable diameter (0.4-3.0 microns), cytoplasmic granules, and spherical (round) bodies with composite structure. This resemblance permits its tentative identification as a Sippewissett strain of Spirosymplokos deltaeiberi. Microbial mats samples collected in sterile Petri dishes and stored dry for more than four years yielded many organisms upon rewetting, including small unidentified spirochetes in at least 4 out of 100 enrichments.

  13. Rotary drum separator system

    NASA Technical Reports Server (NTRS)

    Barone, Michael R. (Inventor); Murdoch, Karen (Inventor); Scull, Timothy D. (Inventor); Fort, James H. (Inventor)

    2009-01-01

    A rotary phase separator system generally includes a step-shaped rotary drum separator (RDS) and a motor assembly. The aspect ratio of the stepped drum minimizes power for both the accumulating and pumping functions. The accumulator section of the RDS has a relatively small diameter to minimize power losses within an axial length to define significant volume for accumulation. The pumping section of the RDS has a larger diameter to increase pumping head but has a shorter axial length to minimize power losses. The motor assembly drives the RDS at a low speed for separating and accumulating and a higher speed for pumping.

  14. Ultrastructure of spermatozoa of the lizard Ameiva ameiva, with considerations on polymorphism within the family Teiidae (Squamata).

    PubMed

    Giugliano, L G; Teixeira, R D; Colli, G R; Báo, S N

    2002-09-01

    A detailed description of sperm ultrastructure of the lizard Ameiva ameiva (Teiidae) is provided. Mature spermatozoa are characterized by: a depressed acrosome at the anterior portion; a unilateral ridge at the anterolateral portion; an acrosome vesicle divided into cortex and medulla; medulla divided into two regions with different electron-densities; paracrystalline subacrosomal material with radial organization in transverse section; a pointed prenuclear perforatorium; a stopper-like perforatorium base plate that appears embedded in the subacrosomal material; the presence of an epinuclear lucent zone surrounded by its own membrane; a large nuclear rostrum; round nuclear shoulders; a nuclear space at the nucleus tip; a bilateral stratified laminar structure; a central dense body within the proximal centriole; a short midpiece; an axonemal midpiece axial component; peripheral fibers 3 and 8 grossly enlarged at the anterior portion of axoneme; columnar mitochondria with linear cristae; solid dense bodies arranged as rings or spirals; a triangular-shaped annulus in transverse section; a fibrous sheath into the midpiece; a thin zone of cytoplasm at the anterior portion of the principal piece; and a slight decrease in diameter of the principal piece immediately after the annulus. Comparisons with Cnemidophorus sexlineatus and Micrablepharus maximiliani failed to identify unique sperm ultrastructure traits of Teiidae or Teiioidea (Teiidae + Gymnophthalmidae). High levels of polymorphism between Ameiva and Cnemidophorus, two closely related genera of the family Teiidae, were detected, suggesting that extensive sampling within squamate families is essential if sperm ultrastructure data are to be used in phylogenetic analyses at this taxonomic level. Copyright 2002 Wiley-Liss, Inc.

  15. The effects of intrathecal nicergoline and nimodipine in cerebral vasospasm: an experimental study in rabbits.

    PubMed

    Solmaz, Ilker; Onal, Mehmet Bulent; Civelek, Erdinc; Kircelli, Atilla; Ongoru, Onder; Ugurel, Sahin; Erdogan, Ersin; Gonul, Engin

    2011-01-01

    the aim of this study was to assess and to compare the ability of intrathecal nicergoline and nimodipine in prevention of cerebral vasospasm in a rabbit model of subarachnoid hemorrhage (SAH). twenty male New Zealand white rabbits were allocated into four groups randomly. Subarachnoid hemorrhage was induced by injecting autologous blood into the cisterna magna. The treatment groups were as follows: (1) control [no SAH (n = 5)], (2) SAH only (n = 5), (3) SAH plus nimodipine (n = 5), and (4) SAH plus nicergoline (n = 5). there was a statistically significant difference between the mean basilar artery cross-sectional areas and the mean arterial wall thickness measurements of the control and SAH-only groups (p < 0.05). Basilar artery vessel diameter and luminal section areas in group 3 were significantly higher than in group 2 (p < 0.05). Basilar artery vessel diameter and basilar artery luminal section areas in group 4 were significantly higher than in group 2 (p < 0.05). There was no significant difference between basilar artery vessel diameter and basilar artery luminal section areas in group 3 and group 4. these findings demonstrate that intrathecal nicergoline has a vasodilatatory effect in an experimental model of SAH in rabbits but not more than that of nimodipine.

  16. Developing high coercivity in large diameter cobalt nanowire arrays

    NASA Astrophysics Data System (ADS)

    Montazer, A. H.; Ramazani, A.; Almasi Kashi, M.; Zavašnik, J.

    2016-11-01

    Regardless of the synthetic method, developing high magnetic coercivity in ferromagnetic nanowires (NWs) with large diameters has been a challenge over the past two decades. Here, we report on the synthesis of highly coercive cobalt NW arrays with diameters of 65 and 80 nm, which are embedded in porous anodic alumina templates with high-aspect-ratio pores. Using a modified electrochemical deposition method enabled us to reach room temperature coercivity and remanent ratio up to 3000 Oe and 0.70, respectively, for highly crystalline as-synthesized hcp cobalt NW arrays with a length of 8 μm. The first-order reversal curve (FORC) analysis showed the presence of both soft and hard magnetic phases along the length of the resulting NWs. To develop higher coercive fields, the length of the NWs was then gradually reduced in order from bottom to top, thereby reaching NW sections governed by the hard phase. Consequently, this resulted in record high coercivities of 4200 and 3850 Oe at NW diameters of 65 and 80 nm, respectively. In this case, the FORC diagrams confirmed a significant reduction in interactions between the magnetic phases of the remaining sections of NWs. At this stage, x-ray diffraction (XRD) and dark-field transmission electron microscopy analyses indicated the formation of highly crystalline bamboo-like sections along the [0 0 2] direction during a progressive pulse-controlled electrochemical growth of NW arrays under optimized parameters. Our results both provide new insights into the growth process, crystalline characteristics and magnetic phases along the length of large diameter NW arrays and, furthermore, develop the performance of pure 3d transition magnetic NWs.

  17. The impact analysis of the connecting pipe length and diameter on the operation of a piston hybrid power machine of positive displacement with gas suction capacity

    NASA Astrophysics Data System (ADS)

    Shcherba, V. E.; Grigoriev, A. V.; Averyanov, G. S.; Surikov, V. I.; Vedruchenko, V. P.; Galdin, N. S.; Trukhanova, D. A.

    2017-08-01

    The article analyzes the impact of the connecting liquid pipe length and diameter on consumables and power characteristics of the piston hybrid power machine with gas suction capacity. The following operating characteristics of the machine were constructed and analyzed: the average height of the liquid column in the jacket space; instantaneous velocity and height of the liquid column in the jacket space; the relative height of the liquid column in the jacket space; volumetric efficiency; indicator isothermal efficiency; flowrate in the pump section; relative pressure losses during suction; relative flowrate. The dependence of the instantaneous pressure in the work space and the suction space of the compressor section on the rotation angle of the crankshaft is determined for different values of the length and diameter of the connecting pipeline.

  18. Retinal vessel diameter and estimated cerebrospinal fluid pressure in arterial hypertension: the Beijing Eye Study.

    PubMed

    Jonas, Jost B; Wang, Ningli; Wang, Shuang; Wang, Ya Xing; You, Qi Sheng; Yang, Diya; Wei, Wen Bin; Xu, Liang

    2014-09-01

    Hypertensive retinal microvascular abnormalities include an increased retinal vein-to-artery diameter ratio. Because central retinal vein pressure depends on cerebrospinal fluid pressure (CSFP), we examined whether the retinal vein-to-artery diameter ratio and other retinal hypertensive signs are associated with CSFP. Participants of the population-based Beijing Eye Study (n = 1,574 subjects) underwent measurement of the temporal inferior and superior retinal artery and vein diameter. CSFP was calculated as 0.44 × body mass index (kg/m(2)) + 0.16 × diastolic blood pressure (mm Hg) - 0.18 × age (years) - 1.91. Larger retinal vein diameters and higher vein-to-artery diameter ratios were significantly associated with higher estimated CSFP (P = 0.001) in multivariable analysis. In contrast, temporal inferior retinal arterial diameter was marginally associated (P = 0.03) with estimated CSFP, and temporal superior artery diameter was not significantly associated (P = 0.10) with estimated CSFP; other microvascular abnormalities, such as arteriovenous crossing signs, were also not significantly associated with estimated CSFP. In a reverse manner, higher estimated CSFP as a dependent variable in the multivariable analysis was associated with wider retinal veins and higher vein-to-artery diameter ratio. In the same model, estimated CSFP was not significantly correlated with retinal artery diameters or other retinal microvascular abnormalities. Correspondingly, arterial hypertension was associated with retinal microvascular abnormalities such as arteriovenous crossing signs (P = 0.003), thinner temporal retinal arteries (P < 0.001), higher CSFP (P < 0.001), and wider retinal veins (P = 0.001) or, as a corollary, with a higher vein-to-artery diameter ratio in multivariable analysis. Wider retinal vein diameters are associated with higher estimated CSFP and vice versa. In arterial hypertension, an increased retinal vein-to-artery diameter ratio depends on elevated CSFP, which is correlated with blood pressure. © American Journal of Hypertension, Ltd 2014. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  19. Paternal Body Mass Index (BMI) Is Associated with Offspring Intrauterine Growth in a Gender Dependent Manner

    PubMed Central

    Chen, You-Peng; Xiao, Xiao-Min; Li, Jian; Reichetzeder, Christoph; Wang, Zi-Neng; Hocher, Berthold

    2012-01-01

    Background Environmental alternations leading to fetal programming of cardiovascular diseases in later life have been attributed to maternal factors. However, animal studies showed that paternal obesity may program cardio-metabolic diseases in the offspring. In the current study we tested the hypothesis that paternal BMI may be associated with fetal growth. Methods and Results We analyzed the relationship between paternal body mass index (BMI) and birth weight, ultrasound parameters describing the newborn's body shape as well as parameters describing the newborns endocrine system such as cortisol, aldosterone, renin activity and fetal glycated serum protein in a birth cohort of 899 father/mother/child triplets. Since fetal programming is an offspring sex specific process, male and female offspring were analyzed separately. Multivariable regression analyses considering maternal BMI, paternal and maternal age, hypertension during pregnancy, maternal total glycated serum protein, parity and either gestational age (for birth weight) or time of ultrasound investigation (for ultrasound parameters) as confounding showed that paternal BMI is associated with growth of the male but not female offspring. Paternal BMI correlated with birth parameters of male offspring only: birth weight; biparietal diameter, head circumference; abdominal diameter, abdominal circumference; and pectoral diameter. Cortisol was likewise significantly correlated with paternal BMI in male newborns only. Conclusions Paternal BMI affects growth of the male but not female offspring. Paternal BMI may thus represent a risk factor for cardiovascular diseases of male offspring in later life. It remains to be demonstrated whether this is linked to an offspring sex specific paternal programming of cortisol secretion. PMID:22570703

  20. Sport-Specific Physiological Adaptations in Highly Trained Endurance Athletes.

    PubMed

    Lundgren, Kari Margrethe; Karlsen, Trine; Sandbakk, Øyvind; James, Philip E; Tjønna, Arnt Erik

    2015-10-01

    This study aims to compare maximal oxygen uptake (V˙O2max), blood volume (BV), hemoglobin mass (Hbmass), and brachial endothelial function, measured as flow-mediated dilatation (FMD), in international-level endurance athletes primarily exercising with the whole body (cross-country skiing), lower body (orienteering), or upper body (flatwater kayak). Seventeen cross-country skiers, 15 orienteers, and 11 flatwater kayakers were tested for V˙O2max, BV, Hbmass, and FMD. Additionally, body composition and annual training (type, volume, and intensity of training) were analyzed. Absolute and body-mass-normalized V˙O2max values were 11.3% and 9.9% higher, respectively, in skiers (5.83 ± 0.60 L·min and 77.9 ± 4.2 mL·min·kg) compared to orienteers (5.24 ± 0.45 L·min and 70.9 ± 3.5 mL·min·kg) (P < 0.01), whereas kayakers (5.78 ± 0.56 L·min and 73.7 ± 6.3 mL·min·kg) did not differ from skiers. BV was 9.9%-11.8% higher in skiers and orienteers compared to kayakers when normalized for total body mass and fat-free mass, and skiers had 9.2% and 9.9% higher Hbmass normalized for total body mass and fat-free mass compared to kayakers (all P < 0.05). Arterial diameter was 11.8%-15.0% larger in kayakers (4.38 ± 0.63 mm) and skiers (4.22 ± 0.36 mm) compared to orienteers (3.81 ± 0.32 mm) (P < 0.05), whereas FMD did not differ between groups. This study indicates that higher V˙O2max in cross-country skiers and greater arterial diameters in the arms of skiers and kayakers are sport-specific physiological adaptations to chronic endurance training in whole-body and upper-body exercise modes. However, variations in these variables are not associated with BV or Hbmass.

  1. Testing of Military Towbars

    DTIC Science & Technology

    2016-09-28

    pin diameters, lunette diameter, clevis end details, cross section, and overall tube length and straightness. b. Weld failures, voids, cracks...etc., should be considered failures if they are identified visually or using a nondestructive weld inspection test method, per the applicable American... Welding Society standard for the specific material being inspected. c. Broken or cracked components, or catastrophic damage should be considered

  2. Design Study for Ground-Based Atmospheric Lidar System.

    DTIC Science & Technology

    1980-09-29

    Diameter: 36 inches with center hole to pass telescope focus Material: Pyrex, Zerodur or equivalent f/number: f/4 Secondary Mirror : Diameter: 10...Measurement of Atmospheric Molecular Density Transmitter Section (includes Laser, Beam Expander and 45 Mirror ) Receiving Telescope (receives...Alignment .. .. ..... 134 6.4 Fixed Autocollimator:Receiver Alignment .. .. ... ....... 136 6.5 Adjustment and Use of Reference Mirrors

  3. Triple Asteroid System Triples Asteroid Observers Interest

    NASA Image and Video Library

    2009-08-06

    NASA Deep Space Network, Goldstone radar images show triple asteroid 1994 CC, which consists of a central object approximately 700 meters 2,300 feet in diameter and two smaller moons that orbit the central body. Animation available at the Photojournal

  4. Volumes and intrinsic diameters of hypersurfaces

    NASA Astrophysics Data System (ADS)

    Paeng, Seong-Hun

    2015-09-01

    We estimate the volume and the intrinsic diameter of a hypersurface M with geometric information of a hypersurface which is parallel to M at distance T. It can be applied to the Riemannian Penrose inequality to obtain a lower bound of the total mass of a spacetime. Also it can be used to obtain upper bounds of the volume and the intrinsic diameter of the celestial r-sphere without a lower bound of the sectional curvature. We extend our results to metric-measure spaces by using the Bakry-Emery Ricci tensor.

  5. Macrosegregation Caused by Convection Associated with Directional Solidification through Cross-Section Change

    NASA Technical Reports Server (NTRS)

    Ghods, M.; Lauer, M.; Tewari, S. N.; Poirier, D. R..; Grugel, R. N.

    2015-01-01

    Al-7 wt% Si and Pb-6 wt% Sb alloy samples were directionally solidified (DS), with liquid above and solid below and gravity pointing down, in cylindrical graphite crucibles through an abrupt cross-section change. Fraction eutectic distribution in the microstructure, primary dendrite spacing and primary dendrite trunk diameters have been measured in the DS samples in the vicinity of section change in order to examine the effect of convection associated with the combined influence of thermosolutal factors and solidification shrinkage. It is observed that convection not only produces extensive radial and axial macrosegregation near cross-section change, it also affects the dendritic array morphology. Primary dendrite spacing and primary dendrite trunk diameter, both, are influenced by this convection. In addition to the experimental results, preliminary results from a numerical model which includes solidification shrinkage and thermosolutal convection in the mushy zone in its analysis will also be presented

  6. Maximum Evaporation Rates of Water Droplets Approaching Obstacles in the Atmosphere Under Icing Conditions

    NASA Technical Reports Server (NTRS)

    Lowell, H. H.

    1953-01-01

    When a closed body or a duct envelope moves through the atmosphere, air pressure and temperature rises occur ahead of the body or, under ram conditions, within the duct. If cloud water droplets are encountered, droplet evaporation will result because of the air-temperature rise and the relative velocity between the droplet and stagnating air. It is shown that the solution of the steady-state psychrometric equation provides evaporation rates which are the maximum possible when droplets are entrained in air moving along stagnation lines under such conditions. Calculations are made for a wide variety of water droplet diameters, ambient conditions, and flight Mach numbers. Droplet diameter, body size, and Mach number effects are found to predominate, whereas wide variation in ambient conditions are of relatively small significance in the determination of evaporation rates. The results are essentially exact for the case of movement of droplets having diameters smaller than about 30 microns along relatively long ducts (length at least several feet) or toward large obstacles (wings), since disequilibrium effects are then of little significance. Mass losses in the case of movement within ducts will often be significant fractions (one-fifth to one-half) of original droplet masses, while very small droplets within ducts will often disappear even though the entraining air is not fully stagnated. Wing-approach evaporation losses will usually be of the order of several percent of original droplet masses. Two numerical examples are given of the determination of local evaporation rates and total mass losses in cases involving cloud droplets approaching circular cylinders along stagnation lines. The cylinders chosen were of 3.95-inch (10.0+ cm) diameter and 39.5-inch 100+ cm) diameter. The smaller is representative of icing-rate measurement cylinders, while with the larger will be associated an air-flow field similar to that ahead of an airfoil having a leading-edge radius comparable with that of the cylinder. It is found that the losses are less than 5 percent. It is concluded that such losses are, in general, very small (less than 1 percent) in the case of smaller obstacles (of icing-rate measurement- cylinder size); the motional dynamics are such, however, that exceptions will occur by reason of failure of very small droplets (moving along stagnation lines) to impinge upon obstacle surfaces. In such cases, the droplets will evaporate completely.

  7. Effect of punch and orifice base sizes in different push-out test setups: stress distribution analysis.

    PubMed

    Zanatta, Rayssa Ferreira; Barreto, Bruno de Castro Ferreira; Xavier, Tathy Aparecida; Versluis, Antheunis; Soares, Carlos José

    2015-02-01

    This study evaluated the influence of punch and base orifice diameters on push-out test results by means of finite element analysis (FEA). FEA was performed using 3D models of the push-out test with 3 base orifice diameters (2.5, 3.0, and 3.5 mm) and 3 punch diameters (0.5, 1.0, and 1.5 mm) using MARC/MENTAT (MSC.Software). The image of a cervical slice from a root restored with a fiberglass post was used to construct the models. The mechanical properties of dentin, post, and resin cement were obtained from the literature. Bases and punches were constructed as rigid bodies. A 10-N force was applied by the punch in the center of the post in a nonlinear contact analysis. Modified von Mises stress, maximum principal stress, as well as shear and normal stress components were calculated. Both punch and base orifice sizes influenced the stress distribution of the push-out test. Bases with larger diameters and punches with smaller diameters caused higher stress in dentin and at the dentin/cement interface. FEA showed that the diameter of the orifice base had a more significant influence on the stress distribution than did the punch diameter. For this reason, both factors should be taken into account during push-out experimental tests.

  8. Automated estimation of abdominal effective diameter for body size normalization of CT dose.

    PubMed

    Cheng, Phillip M

    2013-06-01

    Most CT dose data aggregation methods do not currently adjust dose values for patient size. This work proposes a simple heuristic for reliably computing an effective diameter of a patient from an abdominal CT image. Evaluation of this method on 106 patients scanned on Philips Brilliance 64 and Brilliance Big Bore scanners demonstrates close correspondence between computed and manually measured patient effective diameters, with a mean absolute error of 1.0 cm (error range +2.2 to -0.4 cm). This level of correspondence was also demonstrated for 60 patients on Siemens, General Electric, and Toshiba scanners. A calculated effective diameter in the middle slice of an abdominal CT study was found to be a close approximation of the mean calculated effective diameter for the study, with a mean absolute error of approximately 1.0 cm (error range +3.5 to -2.2 cm). Furthermore, the mean absolute error for an adjusted mean volume computed tomography dose index (CTDIvol) using a mid-study calculated effective diameter, versus a mean per-slice adjusted CTDIvol based on the calculated effective diameter of each slice, was 0.59 mGy (error range 1.64 to -3.12 mGy). These results are used to calculate approximate normalized dose length product values in an abdominal CT dose database of 12,506 studies.

  9. Lateral jet injection into typical combustor flowfields

    NASA Technical Reports Server (NTRS)

    Lilley, D. G.

    1986-01-01

    The experimental problem of lateral jet injection into typical flow fields in the absence of combustion was studied. All flow fields being investigated have no expansion of the crossflow (the test section to swirler diameter ratio D/d = 1), after its passage through an optional swirler (with swirl vane angle phi = 0 (swirler removed), 45, and 70 degree). The lateral jet(s) is(are) located one test-section diameter downstream of the test-section inlet (x/D = 1). The lateral jets have round-sectioned nozzles, each of which has an area of 1/100th of the cross sectional area of the crossflow (A sub j/A sub c = 1/100). Jet-to-crossflow velocity ratios of R = v sub j/u sub o = 2, 4, and 6 were investigated. Helium-bubble low visualization, five-hole pitot probe time-mean velocity measurements, and single-wire time-mean velocity and normal and shear stress turbulence data were obtained in the research program.

  10. Wavelength dependence of the apparent diameter of retinal blood vessels

    NASA Astrophysics Data System (ADS)

    Park, Robert; Twietmeyer, Karen; Chipman, Russell; Beaudry, Neil; Salyer, David

    2005-04-01

    Imaging of retinal blood vessels may assist in the diagnosis and monitoring of diseases such as glaucoma, diabetic retinopathy, and hypertension. However, close examination reveals that the contrast and apparent diameter of vessels are dependent on the wavelength of the illuminating light. In this study multispectral images of large arteries and veins within enucleated swine eyes are obtained with a modified fundus camera by use of intravitreal illumination. The diameters of selected vessels are measured as a function of wavelength by cross-sectional analysis. A fixed scale with spectrally independent dimension is placed above the retina to isolate the chromatic effects of the imaging system and eye. Significant apparent differences between arterial and venous diameters are found, with larger diameters observed at shorter wavelengths. These differences are due primarily to spectral absorption in the cylindrical blood column.

  11. Enzymatically modified isoquercitrin supplementation intensifies plantaris muscle fiber hypertrophy in functionally overloaded mice.

    PubMed

    Kohara, Akiko; Machida, Masanao; Setoguchi, Yuko; Ito, Ryouichi; Sugitani, Masanori; Maruki-Uchida, Hiroko; Inagaki, Hiroyuki; Ito, Tatsuhiko; Omi, Naomi; Takemasa, Tohru

    2017-01-01

    Enzymatically modified isoquercitrin (EMIQ) is produced from rutin using enzymatic hydrolysis followed by treatment with glycosyltransferase in the presence of dextrin to add glucose residues. EMIQ is absorbed in the same way as quercetin, a powerful antioxidant reported to prevent disused muscle atrophy by targeting mitochondria and to have ergogenic effects. The present study investigated the effect of EMIQ on skeletal muscle hypertrophy induced by functional overload. In Study 1, 6-week-old ICR male mice were divided into 4 groups: sham-operated control, sham-operated EMIQ, overload-operated control, and overload-operated EMIQ groups. In Study 2, mice were divided into 3 groups: overload-operated whey control, overload-operated whey/EMIQ (low dose), and overload-operated whey/EMIQ (high dose) groups. The functional overload of the plantaris muscle was induced by ablation of the synergist (gastrocnemius and soleus) muscles. EMIQ and whey protein were administered with food. Three weeks after the operation, the cross-sectional area and minimal fiber diameter of the plantaris muscle fibers were measured. In Study 1, functional overload increased the cross-sectional area and minimal fiber diameter of the plantaris muscle. EMIQ supplementation significantly increased the cross-sectional area and minimal fiber diameter of the plantaris muscle in both the sham-operated and overload-operated groups. In Study 2, EMIQ supplementation combined with whey protein administration significantly increased the cross-sectional area and minimal fiber diameter of the plantaris muscle. EMIQ, even when administered as an addition to whey protein supplementation, significantly intensified the fiber hypertrophy of the plantaris muscle in functionally overloaded mice. EMIQ supplementation also induced fiber hypertrophy of the plantaris in sham-operated mice.

  12. BROACHING AND TUBE-INSTALLING APPARATUS

    DOEpatents

    Frantz, C.E.; Cawley, W.E.

    1961-05-16

    An apparatus is given for sizing long holes in graphite bodies. The apparatus comprises a shaft having 3 spiral broach cutting elements and a straight broach cutting element rotatably mounted thereon. The broach cutting elements are keyed to each other in end to end relationship with the straight broach cutting element at one end of the shaft. The spiral broach cutting elements when considered toward the straight broach cutting element increase in diameter and the cutting teeth thereon increase in lead angle. The straight broach cutting element, when considered in the same direction, increases in diameter from the minimum to maximum diameters of the spiral broach cutting elements. No longitudinal movement of the broach cutting elements is permitted on the shsft snd means are provided for the removal of chips from the apparatus.

  13. Laboratory simulation of the electrodynamic interactions of a tethered satellite with an ionospheric plasma

    NASA Technical Reports Server (NTRS)

    Bonifazi, C.; Lebreton, J. P.; Vannaroni, G.; Cosmovici, C.; Debrie, R.; Hamelin, M.; Pomathiod, L.; Arends, H.

    1986-01-01

    An improved experimental set-up in the Orleans Plasma Chamber allowed investigations of the I-V characteristics of a conductive spherical body (10 cm diameter) in a plasma environment. Moreover, the influence of a transversal magnetic field at 0.6 and 1.2 G was investigated, for the first time, both on the sheath potential profile and current collection. Floating potential profiles were measured at 16 different radial distances from the test body up to 9 body radii in 8 different angular positions. The test body potential could be increased in the range from -200 V up to +100 V. Preliminary results are shown and discussed.

  14. A Newton-Euler Description for Sediment Movement.

    NASA Astrophysics Data System (ADS)

    Maniatis, G.; Hoey, T.; Drysdale, T.; Hodge, R. A.; Valyrakis, M.

    2015-12-01

    We present progress from the development of a purpose specific sensing system for sediment transport (Maniatis et al. 2013). This system utilises the capabilities of contemporary inertial micro-sensors (strap-down accelerometers and gyroscopes) to record fluvial transport from the moving body-frame of artificial pebbles modelled precisely to represent the motion of real, coarse sediment grains (D90=100 mm class). This type of measurements can be useful in the context of sediment transport only if the existing mathematical understanding of the process is updated. We test a new mathematical model which defines specifically how the data recorded in the body frame of the sensor (Lagrangian frame of reference) can be generalised to the reference frame of the flow (channel, Eulerian frame of reference). Given the association of the two most widely used models for sediment transport with those frames of reference (Shields' to Eulerian frame and HA. Einstein's to Lagrangian frame), this description builds the basis for the definition of explicit incipient motion criteria (Maniatis et al. 2015) and for the upscaling from point-grain scale measurements to averaged, cross-sectional, stream related metrics. Flume experiments where conducted in the Hydraulics laboratory of the University of Glasgow where a spherical sensor of 800 mm diameter and capable of recoding inertial dynamics at 80Hz frequency was tested under fluvial transport conditions. We managed to measure the dynamical response of the unit during pre-entrainment/entrainment transitions, on scaled and non-scaled to the sensor's diameter bed and for a range of hydrodynamic conditions (slope up to 0.02 and flow increase rate up to 0.05m3.s-1. Preliminary results from field deployment on a mixed bedrock-alluvial channel are also presented. Maniatis et. al 2013 J. Sens. Actuator Netw. 2013, 2(4), 761-779; Maniatis et. al 2015: "CALCULATION OF EXPLICIT PROBABILITY OF ENTRAINMENT BASED ON INERTIAL ACCELERATION MEASUREMENTS" J. Hydraulic Engineering, Under review.

  15. Do Indo-Asians have smaller coronary arteries?

    PubMed

    Lip, G Y; Rathore, V S; Katira, R; Watson, R D; Singh, S P

    1999-08-01

    There is a widespread belief that coronary arteries are smaller in Indo-Asians. The aim of the present study was to compare the size of atheroma-free proximal and distal epicardial coronary arteries of Indo-Asians and Caucasians. We analysed normal coronary angiograms from 77 Caucasians and 39 Indo-Asians. The two groups were comparable for dominance of the coronary arteries. Indo-Asian patients had generally smaller coronary arteries, with a statistically significant difference in the mean diameters of the left main coronary artery, proximal, mid and left anterior descending, and proximal and distal right coronary artery segments. There was a non-significant trend towards smaller coronary artery segment diameters for the distal left anterior descending, proximal and distal circumflex, and obtuse marginal artery segments. However, after correction for body surface area, none of these differences in size were statistically significant. Thus, the smaller coronary arteries in Indo-Asian patients were explained by body size alone and were not due to ethnic origin per se. This finding nevertheless has important therapeutic implications, since smaller coronary arteries may give rise to technical difficulties during bypass graft and intervention procedures such as percutaneous transluminal coronary angioplasty, stents and atherectomy. On smaller arteries, atheroma may also give an impression of more severe disease than on larger diameter arteries.

  16. Design study of dedicated brain PET with polyhedron geometry.

    PubMed

    Shi, Han; Du, Dong; Xu, JianFeng; Su, Zhihong; Peng, Qiyu

    2015-01-01

    Despite being the conventional choice, whole body PET cameras with a 76 cm diameter ring are not the optimal means of human brain imaging. In fact, a dedicated brain PET with a better geometrical structure has the potential to achieve a higher sensitivity, a higher signal-to-noise ratio, and a better imaging performance. In this study, a polyhedron geometrical dedicated brain PET (a dodecahedron design) is compared to three other candidates via their geometrical efficiencies by calculating the Solid Angle Fractions (SAF); the three other candidates include a spherical cap design, a cylindrical design, and the conventional whole body PET. The spherical cap and the dodecahedron have an identical SAF that is 58.4% higher than that of a 30 cm diameter cylinder and 5.44 times higher than that of a 76 cm diameter cylinder. The conceptual polygon-shape detectors (including pentagon and hexagon detectors based on the PMT-light-sharing scheme instead of the conventional square-shaped block detector module) are presented for the polyhedron PET design. Monte Carlo simulations are performed in order to validate the detector decoding. The results show that crystals in a pentagon-shape detector can be successfully decoded by Anger Logic. The new detector designs support the polyhedron PET investigation.

  17. Image quality phantom and parameters for high spatial resolution small-animal SPECT

    NASA Astrophysics Data System (ADS)

    Visser, Eric P.; Harteveld, Anita A.; Meeuwis, Antoi P. W.; Disselhorst, Jonathan A.; Beekman, Freek J.; Oyen, Wim J. G.; Boerman, Otto C.

    2011-10-01

    At present, generally accepted standards to characterize small-animal single photon emission tomographs (SPECT) do not exist. Whereas for small-animal positron emission tomography (PET), the NEMA NU 4-2008 guidelines are available, such standards are still lacking for small-animal SPECT. More specifically, a dedicated image quality (IQ) phantom and corresponding IQ parameters are absent. The structures of the existing PET IQ phantom are too large to fully characterize the sub-millimeter spatial resolution of modern multi-pinhole SPECT scanners, and its diameter will not fit into all scanners when operating in high spatial resolution mode. We therefore designed and constructed an adapted IQ phantom with smaller internal structures and external diameter, and a facility to guarantee complete filling of the smallest rods. The associated IQ parameters were adapted from NEMA NU 4. An additional parameter, effective whole-body sensitivity, was defined since this was considered relevant in view of the variable size of the field of view and the use of multiple bed positions as encountered in modern small-animal SPECT scanners. The usefulness of the phantom was demonstrated for 99mTc in a USPECT-II scanner operated in whole-body scanning mode using a multi-pinhole mouse collimator with 0.6 mm pinhole diameter.

  18. NT-SiC (new-technology silicon carbide) : Φ 650mm optical space mirror substrate of high-strength reaction-sintered silicon carbide

    NASA Astrophysics Data System (ADS)

    Suyama, Shoko; Itoh, Yoshiyasu; Tsuno, Katsuhiko; Ohno, Kazuhiko

    2005-08-01

    Silicon carbide (SiC) is the most advantageous as the material of various telescope mirrors, because of high stiffness, low density, low coefficient of thermal expansion, high thermal conductivity and thermal stability. Newly developed high-strength reaction-sintered silicon carbide (NTSIC), which has two times higher strength than sintered SiC, is one of the most promising candidates for lightweight optical mirror substrate, because of fully dense, lightweight, small sintering shrinkage (+/-1 %), good shape capability and low processing temperature. In this study, 650mm in diameter mirror substrate of NTSIC was developed for space telescope applications. Three developed points describe below. The first point was to realize the lightweight to thin the thickness of green bodies. Ribs down to 3mm thickness can be obtained by strengthen the green body. The second point was to enlarge the mirror size. 650mm in diameter of mirror substrate can be fabricated with enlarging the diameter in order. The final point was to realize the homogeneity of mirror substrate. Some properties, such as density, bending strength, coefficient of thermal expansion, Young's modulus, Poisson's ratio, fracture toughness, were measured by the test pieces cutting from the fabricated mirror substrates.

  19. Aortic Dissection in Patients With Bicuspid Aortic Valve–Associated Aneurysms

    PubMed Central

    Wojnarski, Charles M.; Svensson, Lars G.; Roselli, Eric E.; Idrees, Jay J.; Lowry, Ashley M.; Ehrlinger, John; Pettersson, Gösta B.; Gillinov, A. Marc; Johnston, Douglas R.; Soltesz, Edward G.; Navia, Jose L.; Hammer, Donald F.; Griffin, Brian; Thamilarasan, Maran; Kalahasti, Vidyasagar; Sabik, Joseph F.; Blackstone, Eugene H.; Lytle, Bruce W.

    2016-01-01

    Background Data regarding the risk of aortic dissection in patients with bicuspid aortic valve and large ascending aortic diameter are limited, and appropriate timing of prophylactic ascending aortic replacement lacks consensus. Thus our objectives were to determine the risk of aortic dissection based on initial cross-sectional imaging data and clinical variables and to isolate predictors of aortic intervention in those initially prescribed serial surveillance imaging. Methods From January 1995 to January 2014, 1,181 patients with bicuspid aortic valve underwent cross-sectional computed tomography (CT) or magnetic resonance imaging (MRI) to ascertain sinus or tubular ascending aortic diameter greater than or equal to 4.7 cm. Random Forest classification was used to identify risk factors for aortic dissection, and among patients undergoing surveillance, time-related analysis was used to identify risk factors for aortic intervention. Results Prevalence of type A dissection that was detected by imaging or was found at operation or on follow-up was 5.3% (n = 63). Probability of type A dissection increased gradually at a sinus diameter of 5.0 cm—from 4.1% to 13% at 7.2 cm—and then increased steeply at an ascending aortic diameter of 5.3 cm—from 3.8% to 35% at 8.4 cm—corresponding to a cross-sectional area to height ratio of 10 cm2/m for sinuses of Valsalva and 13 cm2/m for the tubular ascending aorta. Cross-sectional area to height ratio was the best predictor of type A dissection (area under the curve [AUC] = 0.73). Conclusions Early prophylactic ascending aortic replacement in patients with bicuspid aortic valve should be considered at high-volume aortic centers to reduce the high risk of preventable type A dissection in those with aortas larger than approximately 5.0 cm or with a cross-sectional area to height ratio greater than approximately 10 cm2/m. PMID:26209494

  20. The flux of small near-Earth objects colliding with the Earth.

    PubMed

    Brown, P; Spalding, R E; ReVelle, D O; Tagliaferri, E; Worden, S P

    2002-11-21

    Asteroids with diameters smaller than approximately 50-100 m that collide with the Earth usually do not hit the ground as a single body; rather, they detonate in the atmosphere. These small objects can still cause considerable damage, such as occurred near Tunguska, Siberia, in 1908. The flux of small bodies is poorly constrained, however, in part because ground-based observational searches pursue strategies that lead them preferentially to find larger objects. A Tunguska-class event-the energy of which we take to be equivalent to 10 megatons of TNT-was previously estimated to occur every 200-300 years, with the largest annual airburst calculated to be approximately 20 kilotons (kton) TNT equivalent (ref. 4). Here we report satellite records of bolide detonations in the atmosphere over the past 8.5 years. We find that the flux of objects in the 1-10-m size range has the same power-law distribution as bodies with diameters >50 m. From this we estimate that the Earth is hit on average annually by an object with approximately 5 kton equivalent energy, and that Tunguska-like events occur about once every 1,000 years.

  1. Legless locomotion in lattices

    NASA Astrophysics Data System (ADS)

    Schiebel, Perrin; Dai, Jin; Gong, Chaohui; Serrano, Miguel M.; Mendelson, Joseph R., III; Choset, Howie; Goldman, Daniel I.

    2015-03-01

    By propagating waves from head to tail, limbless organisms like snakes can traverse terrain composed of rocks, foliage, soil and sand. Previous research elucidated how rigid obstacles influence snake locomotion by studying a model terrain-symmetric lattices of pegs placed in hard ground. We want to understand how different substrate-body interaction modes affect performance in desert-adapted snakes during transit of substrates composed of both rigid obstacles and granular media (GM). We tested Chionactis occipitalis, the Mojave shovel-nosed snake, in two laboratory treatments: lattices of 0 . 64 cm diameter obstacles arrayed on both a hard, slick substrate and in a GM of ~ 0 . 3 mm diameter glass particles. For all lattice spacings, d, speed through the hard ground lattices was less than that in GM lattices. However, maximal undulation efficiencies ηu (number of body lengths advanced per undulation cycle) in both treatments were comparable when d was intermediate. For other d, ηu was lower than this maximum in hard ground lattices, while on GM, ηu was insensitive to d. To systematically explore such locomotion, we tested a physical robot model of the snake; performance depended sensitively on base substrate, d and body wave parameters.

  2. Respiratory herpesvirus infection in two Indian Ringneck parakeets.

    PubMed

    Lazic, Tatjana; Ackermann, Mark R; Drahos, Jo M; Stasko, Judith; Haynes, Joseph S

    2008-03-01

    A flock of Indian Ringneck parakeets (Psittacula krameri manillensis) was imported to the United States from Australia. Soon after, 1 parakeet suddenly died, and a second parakeet died after a 2-day course of illness, which consisted of anorexia, lethargy, emaciation, and dyspnea. At necropsy, the affected birds had diffuse consolidation and red discoloration of the lungs, as well as thickened, congested air sacs. The microscopic examination revealed multifocal, necrotizing bronchitis, parabronchitis, and interstitial pneumonia. The lumen of the affected airways contained numerous, large syncytial cells with up to 15 nuclei. The nuclei of these syncytial cells often contained large, eosinophilic inclusion bodies, consistent with herpesvirus. The epithelium of the trachea and air sacs was hypertrophied and contained syncytial cells with intranuclear inclusion bodies similar to the bronchi. In addition, a few intranuclear inclusion bodies were also present in the epithelial cells that line the air capillaries. On ultrastructural examination, the nuclei of degenerating epithelial cells contained clusters of viral nucleocapsid proteins and unenveloped, icosahedral, viral particles that were approximately 90 nm in diameter. In addition, some epithelial cells contained clusters of enveloped viral particles approximately 105 nm in diameter, within the cytocavitary network. These lesions are characteristic of those caused by respiratory herpesvirus of parakeets.

  3. Determination of sex from radiographic measurements of the humerus by discriminant function analysis in Saudi population, Qassim region, KSA.

    PubMed

    Shehri, Fahad Al; Soliman, Khaled E A

    2015-08-01

    Diagnosis of sex from skeleton or individual bone plays an important role in identifying unknown bodies, parts of bodies or skeletal remains for forensic purposes. This study aims to examine the applicability of the measurements taken from the humerus to assess sex, and to contribute to establishing discriminant function equations for Saudi populations for medico legal applications. Archived X-ray radiographs of humerus for 387 patients (216 males & 171 females) who attended the orthopedic clinics at Suleiman Al-Habib Hospital, Qassim region, KSA in the period from January 2011 to December 2013 were reviewed and analyzed. Five dimensions, including maximum length, vertical head diameter, diameter of head+greater tubercle, right-left diameter at midshaft, and epicondylar breadth were taken and subjected to Univariate and multivariate discriminant function analysis. The studied radiographic dimensions of the humerus indicate that there are significant differences (p<0.05) between the males and females measurements while the difference between right and left measurements was not significant. The findings revealed that the proximal part of the humerus has greater diagnostic accuracy than distal and middle parts. Accuracy of correct classification varies between 68.0% (epicondylar breadth) and 90.4% (vertical head diameter) for univariate analyses. When the multivariate analyses were conducted, three functions were produced, with the accuracy of ranging between 88.4% and 94.3%. These findings suggested that the dimensions of the humerus, especially the measurements taken from the proximal parts, could be used successfully for sex diagnosis. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  4. Recovering 3D Particle Size Distributions from 2D Sections

    NASA Technical Reports Server (NTRS)

    Cuzzi, Jeffrey N.; Olson, Daniel A.

    2017-01-01

    We discuss different ways to convert observed, apparent particle size distributions from 2D sections (thin sections, SEM maps on planar surfaces, etc.) into true 3D particle size distributions. We give a simple, flexible and practical method to do this, show which of these techniques gives the most faithful conversions, and provide (online) short computer codes to calculate both 2D- 3D recoveries and simulations of 2D observations by random sectioning. The most important systematic bias of 2D sectioning, from the standpoint of most chondrite studies, is an overestimate of the abundance of the larger particles. We show that fairly good recoveries can be achieved from observed size distributions containing 100-300 individual measurements of apparent particle diameter. Proper determination of particle size distributions in chondrites - for chondrules, CAIs, and metalgrains - is of basic importance for assessing the processes of formation and/or of accretion of theseparticles into their parent bodies. To date, most information of this sort is gathered from 2D samplescut from a rock such as in microscopic analysis of thin sections, or SEM maps of planar surfaces(Dodd 1976, Hughes 1978a,b; Rubin and Keil 1984, Rubin and Grossman 1987, Grossman et al1988, Rubin 1989, Metzler et al 1992, Kuebler et al 1999, Nelson and Rubin 2002, Schneider et al 2003, Hezel et al 2008; Fisher et al 2014; for an exhaustive review with numerous references seeFriedrich et al 2014). While qualitative discrimination between chondrite types can readily be doneusing data of this sort, any deeper exploration of the processes by which chondrite constituents werecreated or emplaced into their parent requires a more quantitative approach.

  5. Comparison of Impact Crater Size-Frequency Distributions (SFD) on Saturnian Satellites with Other Solar-System Bodies

    NASA Astrophysics Data System (ADS)

    Schmedemann, N.; Neukum, G.; Denk, T.; Wagner, R.; Hartmann, O.

    2009-04-01

    The examination of the geologic history of the saturnian satellites is a major goal of the Cassini imaging experiment (ISS) [5]. The study of the impact crater-SFD is necessary to derive ages of the saturnian satellite surface units. Furthermore it can be used for resolving the main impactor source and the impactor orbital characteristics for understanding the nature of the bombardment. While large and old areas are suited to measure the branch of large crater sizes, smaller craters can be found in a state of production only at relatively young areas on the saturnian satellites. The impact-crater SFD is derived only from such crater populations which are in production. Hence the measurement of the whole production function in one specific area is impossible. Therefore we have to measure it piece-wise in crater size range in a number of suitable areas. On Iapetus the production function has been measured in seven crater size range pieces, covering a crater size range from 0.15 km to 700 km. At the same crater size, these areas have somewhat different crater frequencies, since they are of different ages. The crater frequency differences of the respective pieces to each other have to be taken out, in order to obtain continuous curves. We have achieved that by normalizing the frequencies measured on the older surface units at the respective smallest crater sizes to the tail ends of the crater frequencies for the largest craters on the younger surface units. The resulting continuous curves give us a reliable production SFD over the whole accessible range. Doing so, we assumed that the production SFD has not changed over time in the parts of the SFD not directly accessible by measurement. Hence the resulting SFD curve is a consequence of a compilation of measurements taken in different areas. Intensive analyses of the crater diameter SFD of the lunar surface have revealed a characteristic W-shaped curve, when it is R-plotted. Crater counting on other planetary surfaces such as Mercury, Venus, Mars, Gaspra, Callisto, Ganymede and Mimas have revealed similarly shaped crater diameter SFDs e.g. [4]. While those SFD curves are equally shaped, the whole curves with their characteristic W-shapes appear to be shifted along the diameter axis. Most likely, this shift is primarily the result of different impact velocities. Other factors of scaling relationships between crater diameter and projectile diameter such as density and gravity on different target bodies are of secondary importance. The measurements of the crater diameter SFD on the saturnian satellites Tethys, Dione, Rhea, and Iapetus also show high similarities to the lunar W-shaped curve. The most complete and statistically valid data set was generated in the case of Iapetus. We have been able to measure crater sizes over four orders of magnitude. The most likely impactor source for the craters in the inner solar system is the asteroid belt orbiting the sun between Mars and Jupiter e.g. [3],[4]. The asteroid body diameter SFD has more recently been analyzed by [2] using the latest discoveries and the absolute geometric albedo of the asteroids. Those albedo values have been converted to asteroid-body diameters using the method of [1]. The body SFD of the asteroid belt in the range from its inner border out to the 5:2 resonance gap gives a very good match to the lunar SFD. The same W-shape characteristics is found at the jovian and saturnian satellite SFD curves as mentioned earlier. Based on these observations and similarities, it is reasonable to suspect asteroids as the major contribution for the outer solar system bombardment in the range of Saturn as well. References: [1]Fowler & Chillemi (1992) in "The IRAS minor planet survey" [2]Ivanov at al. (2002) in „Asteroids III"; The University of Arizona Press: 89-101 [3]Neukum (1983) Habilitation Thesis, "Meteoritenbombardement und Datierung planetarer Oberflächen"; Ludwig-Maximilians-University of Munich. [4]Neukum & Ivanov (1994) in "Hazards due to comets & Asteroids"; The University of Arizona Press: 359-416 [5]Porco et al. (2004) Space Science Reviews 115: 363-497

  6. Resinless section electron microscopy reveals the yeast cytoskeleton

    PubMed Central

    Penman, Joshua; Penman, Sheldon

    1997-01-01

    The cytoskeleton of Saccharomyces cerevisiae is essentially invisible using conventional microscopy techniques. A similar problem was solved for the mammalian cell cytoskeleton using resinless section electron microscopy, a technique applied here to yeast. In the resinless image, soluble proteins are no longer cloaked by embedding medium and must be removed by selective detergent extraction. In yeast, this requires breaching the cell wall by digesting with Zymolyase sufficiently to allow detergent extraction of the plasma membrane lipids. Gel electropherograms show that the extracted or “soluble” proteins are distinct from the retained or “structural” proteins that presumably comprise the cytoskeleton. These putative cytoskeleton proteins include the major portions of a 43-kDa protein, which is presumably actin, and of proteins in a band appearing at 55 kDa, as well as numerous less abundant, nonactin proteins. Resinless section electron micrographs show a dense, three-dimensional web of anastomosing, polymorphic filaments bounded by the remnant cell wall. Although the filament network is very heterogenous, there appear to be two principal classes of filament diameters—5 nm and 15–20 nm—which may correspond to actin and intermediate filaments, respectively. A large oval region of lower filament density probably corresponds to the vacuole, and an electron dense spheroidal body, 300–500 nm in diameter, is likely the nucleus. The techniques detailed in this report afford new approaches to the study of yeast cytoarchitecture. PMID:9108046

  7. Fluoroscopic tomography. [for body section synthesis

    NASA Technical Reports Server (NTRS)

    Baily, N. A.; Crepeau, R. L.; Lasser, E. C.

    1974-01-01

    A fluoroscopic tomography system capable of synthesizing body sections at a number of levels within the body has been developed. The synthesized body sections may lie either in a range of planes parallel to, tilted with respect to, skewed with respect to, or both tilted and skewed with respect to the plane of motion of the X-ray tube target. In addition, body sections can be presented which are contoured to the patient's anatomy. That is to say, they may even encompass such complex surfaces as a quadratic hyperplane. In addition, tomograms of organs in motion can be imaged.

  8. Development of a probe for inner profile measurement and flaw detection

    NASA Astrophysics Data System (ADS)

    Yoshizawa, Toru; Wakayama, Toshitaka; Kamakura, Yoshihisa

    2011-08-01

    It is one of the important necessities to precisely measure the inner diameter and/or the inner profile of pipes, tubes and other objects similar in shape. Especially in mechanical engineering field, there are many requests from automobile industry because the inner surface of engine blocks and other die casts are strongly required to be inspected and measured by non-contact methods (not by the naked eyes inspection using a borescope). If the inner diameter is large enough like water pipes or drain pipes, complicated and large equipment may be applicable. However, small pipes with a diameter ranging from 10mm to 100mm are difficult to be inspected by such a large instrument as is used for sewers inspection. And we have proposed an instrument which has no moving elements such as a rotating mirror or a prism for scanning a beam. Our measurement method is based on optical sectioning using triangulation. This optically sectioned profile of an inner wall of pipe-like objects is analyzed to produce numerical data of inner diameter or profile. Here, we report recent development of the principle and applications of the optical instrument with a simple and compact configuration. In addition to profile measurement, we found flaws and defects on the inner wall were also detected by using the similar principle. Up to now, we have developed probes with the diameter of 8mm to 25mm for small size objects and another probe (80 mm in diameter) for such a larger container with the dimensional size of 600mm.

  9. Selective control of small versus large diameter axons using infrared laser light (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Lothet, Emilie H.; Shaw, Kendrick M.; Horn, Charles C.; Lu, Hui; Wang, Yves T.; Jansen, E. Duco; Chiel, Hillel J.; Jenkins, Michael W.

    2016-03-01

    Sensory information is conveyed to the central nervous system via small diameter unmyelinated fibers. In general, smaller diameter axons have slower conduction velocities. Selective control of such fibers could create new clinical treatments for chronic pain, nausea in response to chemo-therapeutic agents, or hypertension. Electrical stimulation can control axonal activity, but induced axonal current is proportional to cross-sectional area, so that large diameter fibers are affected first. Physiologically, however, synaptic inputs generally affect small diameter fibers before large diameter fibers (the size principle). A more physiological modality that first affected small diameter fibers could have fewer side effects (e.g., not recruiting motor axons). A novel mathematical analysis of the cable equation demonstrates that the minimum length along the axon for inducing block scales with the square root of axon diameter. This implies that the minimum length along an axon for inhibition will scale as the square root of axon diameter, so that lower radiant exposures of infrared light will selectively affect small diameter, slower conducting fibers before those of large diameter. This prediction was tested in identified neurons from the marine mollusk Aplysia californica. Radiant exposure to block a neuron with a slower conduction velocity (B43) was consistently lower than that needed to block a faster conduction velocity neuron (B3). Furthermore, in the vagus nerve of the musk shrew, lower radiant exposure blocked slow conducting fibers before blocking faster conducting fibers. Infrared light can selectively control smaller diameter fibers, suggesting many novel clinical treatments.

  10. Evolutionary allometry of the thoracolumbar centra in felids and bovids.

    PubMed

    Jones, Katrina E

    2015-07-01

    Mammals have evolved a remarkable range of body sizes, yet their overall body plan remains unaltered. One challenge of evolutionary biology is to understand the mechanisms by which this size diversity is achieved, and how the mechanical challenges associated with changing body size are overcome. Despite the importance of the axial skeleton in body support and locomotion, and much interest in the allometry of the appendicular skeleton, little is known about vertebral allometry outside primates. This study compares evolutionary allometry of the thoracolumbar centra in two families of quadrupedal running mammals: Felidae and Bovidae. I test the hypothesis that, as size increases, the thoracolumbar region will resist increasing loads by becoming a) craniocaudally shorter, and b) larger in cross-sectional area, particularly in the sagittal plane. Length, width, and height of the thoracolumbar centra of 23 felid and 34 bovid species were taken. Thoracic, prediaphragmatic, lumbar, and postdiaphragmatic lengths were calculated, and diameters were compared at three equivalent positions: the midthoracic, the diaphragmatic and the midlumbar vertebra. Allometric slopes were calculated using a reduced major axis regression, on both raw and independent contrasts data. Slopes and elevations were compared using an ANCOVA. As size increases the thoracolumbar centra become more robust, showing preferential reinforcement in the sagittal plane. There was less allometric shortening of the thoracic than the lumbar region, perhaps reflecting constraints due to its connection with the respiratory apparatus. The thoracic region was more robust in bovids than felids, whereas the lumbar region was longer and more robust in felids than bovids. Elongation of lumbar centra increases the outlever of sagittal bending at intervertebral joints, increasing the total pelvic displacement during dorsomobile running. Both locomotor specializations and functional regionalization of the axial skeleton appear to have influenced its response to increasing size. © 2015 Wiley Periodicals, Inc.

  11. 40 CFR 1066.225 - Roll runout and diameter verification procedure.

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... section. (2) Measure roll diameter using a Pi Tape®. Orient the Pi Tape® to the marker line at the desired measurement location with the Pi Tape® hook pointed outward. Temporarily secure the Pi Tape® to the roll near the hook end with adhesive tape. Slowly turn the roll, wrapping the Pi Tape® around the roll surface...

  12. 40 CFR 1066.225 - Roll runout and diameter verification procedure.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... section. (2) Measure roll diameter using a Pi Tape®. Orient the Pi Tape® to the marker line at the desired measurement location with the Pi Tape® hook pointed outward. Temporarily secure the Pi Tape® to the roll near the hook end with adhesive tape. Slowly turn the roll, wrapping the Pi Tape® around the roll surface...

  13. 77 FR 31843 - Swan Lake North Hydro, LLC; Notice of Preliminary Permit Application Accepted For Filing and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-05-30

    ... California; and (14) appurtenant facilities. The project would be a closed-loop system using groundwater and... application for a successive preliminary permit, pursuant to section 4(f) of the Federal Power Act (FPA... power tunnel; (6) a 30-foot-diameter, 1,200-foot-long vertical shaft; (7) a 30-foot-diameter, 1,000-foot...

  14. 78 FR 10134 - Welded Large Diameter Line Pipe From Japan: Final Results of the Expedited Second Sunset Review...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-13

    ... Pipe From Japan: Final Results of the Expedited Second Sunset Review of the Antidumping Duty Order... antidumping duty order on welded large diameter line pipe (line pipe) from Japan pursuant to section 751(c) of... Department initiated the sunset review of the antidumping duty order on line pipe from Japan pursuant to...

  15. On-line measurement of diameter of hot-rolled steel tube

    NASA Astrophysics Data System (ADS)

    Zhu, Xueliang; Zhao, Huiying; Tian, Ailing; Li, Bin

    2015-02-01

    In order to design a online diameter measurement system for Hot-rolled seamless steel tube production line. On one hand, it can play a stimulate part in the domestic pipe measuring technique. On the other hand, it can also make our domestic hot rolled seamless steel tube enterprises gain a strong product competitiveness with low input. Through the analysis of various detection methods and techniques contrast, this paper choose a CCD camera-based online caliper system design. The system mainly includes the hardware measurement portion and the image processing section, combining with software control technology and image processing technology, which can complete online measurement of heat tube diameter. Taking into account the complexity of the actual job site situation, it can choose a relatively simple and reasonable layout. The image processing section mainly to solve the camera calibration and the application of a function in Matlab, to achieve the diameter size display directly through the algorithm to calculate the image. I build a simulation platform in the design last phase, successfully, collect images for processing, to prove the feasibility and rationality of the design and make error in less than 2%. The design successfully using photoelectric detection technology to solve real work problems

  16. Measuring impact crater depth throughout the solar system

    USGS Publications Warehouse

    Robbins, Stuart J.; Watters, Wesley A.; Chappelow, John E.; Bray, Veronica J.; Daubar, Ingrid J.; Craddock, Robert A.; Beyer, Ross A.; Landis, Margaret E.; Ostrach, Lillian; Tornabene, Livio L.; Riggs, Jamie D.; Weaver, Brian P.

    2018-01-01

    One important, almost ubiquitous, tool for understanding the surfaces of solid bodies throughout the solar system is the study of impact craters. While measuring a distribution of crater diameters and locations is an important tool for a wide variety of studies, so too is measuring a crater's “depth.” Depth can inform numerous studies including the strength of a surface and modification rates in the local environment. There is, however, no standard data set, definition, or technique to perform this data‐gathering task, and the abundance of different definitions of “depth” and methods for estimating that quantity can lead to misunderstandings in and of the literature. In this review, we describe a wide variety of data sets and methods to analyze those data sets that have been, are currently, or could be used to derive different types of crater depth measurements. We also recommend certain nomenclature in doing so to help standardize practice in the field. We present a review section of all crater depths that have been published on different solar system bodies which shows how the field has evolved through time and how some common assumptions might not be wholly accurate. We conclude with several recommendations for researchers which could help different data sets to be more easily understood and compared.

  17. Effect of alkali on the structure of cell envelopes of Chlamydia psittaci elementary bodies.

    PubMed Central

    Narita, T; Wyrick, P B; Manire, G P

    1976-01-01

    Suspensions of isolated cell envelopes of infectious elementary bodies (EB) of Chlamydia psittaci at alkaline pH showed a rapid, extensive decrease in absorbance, accompanied by the release of a cell envelope component in a sedimentable form. This phenomenon was observed both at 0 C and with envelopes which had been previously heated to 100 C. Monovalent and divalent cations effectively inhibited the turbidity loss, whereas ethylenediaminetetraacetate (EDTA) caused an accelerated decrease in turbidity. The turbidity loss observed after incubation of the envelopes at alkaline pH could be reversed to the level of the initial value by dialysis against distilled water containing Mg2+. Thin-section electron photomicrographs of purified EB exposed to alkaline buffer with EDTA revealed the loss of the internal contents of cells, but these cells still maintained their round shapes. The cell surface of treated EB appeared pitted in negatively stained preparations, whereas intact EB had a smooth surface. Electron microscopic studies on negatively stained preparations of the clear supernatant obtained after the treatment of the envelope with alkaline buffer containing EDTA demonstrated the presence of spherical particles, approximately 6 to 7 nm in diameter, and rodlike particles, which appeared to be made up of two or more spherical particles. Images PMID:1375

  18. Correlation between pre-pregnancy body mass index and maternal visceral adiposity with fetal biometry during the second trimester.

    PubMed

    Lopes, Karina R M; Souza, Alex Sandro R; Figueiroa, José N; Alves, João Guilherme B

    2017-08-01

    To determine the correlation between pre-pregnancy body mass index (BMI) and maternal visceral adiposity with fetal biometry during the second trimester. A cross-sectional observational study was conducted among pregnant women who received prenatal care at a center in Recife, Brazil, between October 3, 2011, and September 27, 2013. Pre-pregnancy BMI was determined at the first prenatal care visit. Maternal visceral adiposity and fetal biometry were measured at the same ultrasonography session. The associations between maternal and fetal variables were evaluated using the Pearson correlation coefficient (R). The Student t test was used to test the null hypothesis of adjusted correlation coefficients. Overall, 740 women were included. No correlation was found between pre-pregnancy BMI and any of the fetal biometric variables assessed. By contrast, maternal visceral adiposity positively correlated with fetal abdominal circumference (R=0.529), estimated fetal weight (R=0.524), head circumference (R=0.521), femur length (R=0.521), and biparietal diameter (R=0.524; P<0.001 for all fetal variables). These findings remained statistically significant after controlling for pregnancy length. Maternal visceral adiposity, but not pre-pregnancy BMI, positively correlated with fetal biometry during the second trimester. © 2017 International Federation of Gynecology and Obstetrics.

  19. Measurement of retinal wall-to-lumen ratio by adaptive optics retinal camera: a clinical research.

    PubMed

    Meixner, Eva; Michelson, Georg

    2015-11-01

    To measure the wall-to-lumen ratio (WLR) and the cross-sectional area of the vascular wall (WCSA) of retinal arterioles by an Adaptive Optics (AO) retinal camera. Forty-seven human subjects were examined and their medical history was explored. WLR and WCSA were measured on the basis of retinal arteriolar wall thickness (VW), lumen diameter (LD) and vessel diameter (VD) assessed by rtx1 Adaptive Optics retinal camera. WLR was calculated by the formula [Formula: see text]. Arterio-venous ratio (AVR) and microvascular abnormalities were attained by quantitative and qualitative assessment of fundus photographs. Influence of age, arterial hypertension, body mass index (BMI) and retinal microvascular abnormalities on the WLR was examined. An age-adjusted WLR was created to test influences on WLR independently of age. Considering WLR and WCSA, a distinction between eutrophic and hypertrophic retinal remodeling processes was possible. The intra-observer variability (IOV) was 6 % ± 0.9 for arteriolar wall thickness and 2 % ± 0.2 for arteriolar wall thickness plus vessel lumen. WLR depended significantly on the wall thickness (r = 0.715; p < 0.01) of retinal arterioles, but was independent of the total vessel diameter (r = 0.052; p = 0.728). WLR correlated significantly with age (r = 0.769; p < 0.01). Arterial hypertension and a higher BMI were significantly associated with an increased age-adjusted WLR. WLR correlated significantly with the stage of microvascular abnormalities. 55 % of the hypertensive subjects and 11 % of the normotensive subjects showed eutrophic remodeling, while hypertrophic remodeling was not detectable. WLR correlated inversely with AVR. AVR was independent of the arteriolar wall thickness, age and arterial hypertension. The technique of AO retinal imaging allows a direct measurement of the retinal vessel wall and lumen diameter with good intra-observer variability. Age, arterial hypertension and an elevated BMI level are significantly associated with an increased WLR. The wall-to-lumen ratio measured by AO can be used to detect structural retinal microvascular alterations in an early stage of remodeling processes.

  20. Estimation of the Mean Axon Diameter and Intra-axonal Space Volume Fraction of the Human Corpus Callosum: Diffusion q-space Imaging with Low q-values.

    PubMed

    Suzuki, Yuriko; Hori, Masaaki; Kamiya, Kouhei; Fukunaga, Issei; Aoki, Shigeki; VAN Cauteren, Marc

    2016-01-01

    Q-space imaging (QSI) is a diffusion-weighted imaging (DWI) technique that enables investigation of tissue microstructure. However, for sufficient displacement resolution to measure the microstructure, QSI requires high q-values that are usually difficult to achieve with a clinical scanner. The recently introduced "low q-value method" fits the echo attenuation to only low q-values to extract the root mean square displacement. We investigated the clinical feasibility of the low q-value method for estimating the microstructure of the human corpus callosum using a 3.0-tesla clinical scanner within a clinically feasible scan time. We performed a simulation to explore the acceptable range of maximum q-values for the low q-value method. We simulated echo attenuations caused by restricted diffusion in the intra-axonal space (IAS) and hindered diffusion in the extra-axonal space (EAS) assuming 100,000 cylinders with various diameters, and we estimated mean axon diameter, IAS volume fraction, and EAS diffusivity by fitting echo attenuations with different maximum q-values. Furthermore, we scanned the corpus callosum of 7 healthy volunteers and estimated the mean axon diameter and IAS volume fraction. Good agreement between estimated and defined values in the simulation study with maximum q-values of 700 and 800 cm(-1) suggested that the maximum q-value used in the in vivo experiment, 737 cm(-1), was reasonable. In the in vivo experiment, the mean axon diameter was larger in the body of the corpus callosum and smaller in the genu and splenium, and this anterior-to-posterior trend is consistent with previously reported histology, although our mean axon diameter seems larger in size. On the other hand, we found an opposite anterior-to-posterior trend, with high IAS volume fraction in the genu and splenium and a lower fraction in the body, which is similar to the fiber density reported in the histology study. The low q-value method may provide insights into tissue microstructure using a 3T clinical scanner within clinically feasible scan time.

  1. Measurements of Local Heat Transfer and Pressure on Six 2-Inch-Diameter Blunt Bodies at a Mach Number of 4.95 and at Reynolds Numbers Per Foot up to 81 x 10(exp 6)

    NASA Technical Reports Server (NTRS)

    Cooper, Morton; Mayo, Edward E.

    1959-01-01

    Measurements of the local heat transfer and pressure distribution have been made on six 2-inch-diameter, blunt, axially symmetric bodies in the Langley gas dynamics laboratory at a Mach number of 4.95 and at Reynolds numbers per foot up to 81 x 10(exp 6). During the investigation laminar flow was observed over a hemispherical-nosed body having a surface finish from 10 to 20 microinches at the highest test Reynolds number per foot (for this configuration) of 77.4 x 10(exp 6). Though it was repeatedly possible to measure completely laminar flow at this Reynolds number for the hemisphere, it was not possible to observe completely laminar flow on the flat-nosed body for similar conditions. The significance of this phenomenon is obscured by the observation that the effects of particle impacts on the surface in causing roughness were more pronounced on the flat-nosed body. For engineering purposes, a method developed by M. Richard Dennison while employed by Lockheed Aircraft Corporation appears to be a reasonable procedure for estimating turbulent heat transfer provided transition occurs at a forward location on the body. For rearward-transition locations, the method is much poorer for the hemispherical nose than for the flat nose. The pressures measured on the hemisphere agreed very well with those of the modified Newtonian theory, whereas the pressures on all other bodies, except on the flat-nosed body, were bracketed by modified Newtonian theory both with and without centrifugal forces. For the hemisphere, the stagnation-point velocity gradient agreed very well with Newtonian theory. The stagnation-point velocity gradient for the flat- nosed model was 0.31 of the value for the hemispherical-nosed model. If a Newtonian type of flow is assumed, the ratio 0.31 will be independent of Much number and real-gas effects.

  2. Abdominal aortic aneurysm neck remodeling after Anaconda stent graft implantation.

    PubMed

    Vukovic, Elisabeth; Czerny, Martin; Beyersdorf, Friedhelm; Wolkewitz, Martin; Berezowski, Mikolaj; Siepe, Matthias; Blanke, Philipp; Rylski, Bartosz

    2018-05-24

    The aim of this study was to define how the proximal landing zone changes geometrically after endovascular abdominal aortic aneurysm repair (EVAR) with the Anaconda (Vascutek, Inchinnan, United Kingdom) stent graft. Among 230 patients who underwent Anaconda stent graft implantation between 2005 and 2014, we included 126 with adequate computed tomography (CT) image quality and follow-up. CT analysis entailed the geometric changes in the main body, proximal rings, and proximal landing zone. The median CT follow-up was 2.0 years (345.8 patients-years). The proximal portion of the main body ring system flattened within the first year after EVAR, resulting in an up to 30° increase in the upper ring's angle in 40% patients and up to 40° increase in 24% patients. One year after EVAR, the upper ring angle increase slowed down. Aortic diameter measured at the level of the upper and lower ring expanded by 2 to 4 mm within 1 year, but remained unchanged afterward. The main body migrated continuously down toward the aortic bifurcation, attaining an average 6-mm increase in the distance between the superior mesenteric artery and main body within 4 years. Freedom from endoleak type IA was 95 ± 2% and 93 ± 3% after 1 and 4 years, respectively. The Anaconda main body ring system in its proximal portion flattens within the first year after EVAR, leading to an increase of 2 to 4 mm in the proximal landing zone's aortic diameter. The main body migrates slowly but continuously down toward the aortic bifurcation. Copyright © 2018 Society for Vascular Surgery. Published by Elsevier Inc. All rights reserved.

  3. Craters formed in mineral dust by hypervelocity microparticles.

    NASA Technical Reports Server (NTRS)

    Vedder, J. F.

    1972-01-01

    As a simulation of erosion processes on the lunar surface, impact craters were formed in dust targets by 2- to 5-micron-diameter polystyrene spheres with velocities between 2.5 and 12 km/sec. For weakly cohesive, thick targets of basalt dust with a maximum grain size comparable to the projectile diameter, the craters had an average projectile-to-diameter diameter ratio of 25, and the displaced mass was 3 orders of magnitude greater than the projectile mass. In a simulation of the effect of a dust covering on lunar rocks, a layer of cohesive, fine-grained basalt dust with a thickness nearly twice the projectile diameter protected a glass substrate from damage, but an area about 50 times the cross-sectional area of the projectile was cleared of all but a few grains. Impact damage was produced in glass under a thinner dust layer.

  4. Effect of Shock Precompression on the Critical Diameter of Liquid Explosives

    NASA Astrophysics Data System (ADS)

    Petel, Oren E.; Higgins, Andrew J.; Yoshinaka, Akio C.; Zhang, Fan

    2006-07-01

    The critical diameter of both ambient and shock-precompressed liquid nitromethane confined in PVC tubing are measured experimentally. The experiment was conducted for both amine sensitized and neat NM. In the precompression experiments, the explosive is compressed by a strong shock wave generated by a donor explosive and reflected from a high impedance anvil prior to being detonated by a secondary event. The pressures reached in the test sections prior to detonation propagation was approximately 7 and 8 GPa for amine sensitized and neat NM respectively. The results demonstrated a 30% - 65% decrease in the critical diameter for the shock-compressed explosives. This critical diameter decrease is observed despite a significant decrease in the predicted Von Neumann temperature of the detonation in the precompressed explosive. The results are discussed in the context of theoretical predictions based on thermal ignition theory and previous critical diameter measurements.

  5. FCI experiments in the corium/water system

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Huhtiniemi, I.; Hohmann, H.; Magallon, D.

    The KROTOS fuel coolant interaction (FCI) tests aim at providing benchmark data to examine the effect of fuel/coolant initial conditions and mixing on explosion energetics. Experiments, fundamental in nature, are performed in well-controlled geometries and are complementary to the FARO large scale tests. Recently, a new test series was started using 3 kg of prototypical core material (80 w/o UO{sub 2}, 20 w/o ZrO{sub 2}) which was poured into a water column of {le} 1.25 m in height (95 mm and 200 mm in diameter) under 0.1 MPa ambient pressure. Four tests have been performed in the test section ofmore » 95 mm in diameter (ID) with different subcooling levels (10-80K) and with and without an external trigger. Additionally, one test has been performed with a test section of 200 mm in diameter (ID) and with an external trigger. No spontaneous or triggered energetic FCIs (steam explosions) have been observed in these corium tests. This is in sharp contrast with the steam explosions observed in the previously reported Al{sub 2}O{sub 3} test series which had the same initial conditions of ambient pressure and subcooling. The post-test analysis of the corium experiments indicated that strong vaporisation at the melt/water contact led to a partial expulsion of the melt from the test section into the pressure vessel. In order to avoid this and to obtain a good penetration and premixing os the corium melt, an additional test has been performed with a larger diameter test section. In all the UO{sub 2}-ZrO{sub 2} tests an efficient quenching process (0.7-1.2 MW/kg-melt) with total fuel fragmentation (mass mean diameter 1.4-2.5 mm) was observed. Results from Al{sub 2}O{sub 3} tests under the same initial conditions are also presented for further confirmation of the observed differences in behaviour between Al{sub 2}O{sub 3} and UO{sub 2}-ZrO{sub 2} melts.« less

  6. Parametric study of shock-induced combustion in a hydrogen air system

    NASA Technical Reports Server (NTRS)

    Ahuja, J. K.; Tiwari, Surendra N.

    1994-01-01

    A numerical parametric study is conducted to simulate shock-induced combustion under various free-stream conditions and varying blunt body diameter. A steady combustion front is established if the free-stream Mach number is above the Chapman-Jouguet speed of the mixture, whereas an unsteady reaction front is established if the free-stream Mach number is below or at the Chapman-Jouguet speed of the mixture. The above two cases have been simulated for Mach 5.11 and Mach 6.46 with a projectile diameter of 15 mm. Mach 5.11, which is an underdriven case, shows an unsteady reaction front, whereas Mach 6.46, which is an overdriven case, shows a steady reaction front. Next for Mach 5. 11 reducing the diameter to 2.5 mm causes the instabilities to disappear, whereas, for Mach 6.46 increasing the diameter of the projectile to 225 mm causes the instabilities to reappear, indicating that Chapman-Jouguet speed is not the only deciding factor for these instabilities to trigger. The other key parameters are the projectile diameter, induction time, activation energy and the heat release. The appearance and disappearance of the instabilities have been explained by the one-dimensional wave interaction model.

  7. Transcatheter closure of moderate-to-large patent ductus arteriosus in infants using Amplatzer duct occluder.

    PubMed

    Wang, Jou-Kou; Wu, Mei-Hwan; Lin, Ming-Tai; Chiu, Shuenn-Nan; Chen, Chun-An; Chiu, Hsin-Hui

    2010-02-01

    There are difficulties in transcatheter closure of patent ductus arteriosus (PDA) in infants. The 46 infants (mean age 6.2+/-2.7 months; mean body weight 6.3+/-1.6 kg) who underwent PDA closure using the Amplatzer duct occluder (ADO). The indication for using an ADO was a ductus diameter > or =2.5 or 3 mm. Device diameter selected was 1-3 mm larger than ductal diameter. The mean systolic pulmonary artery pressure was 40.9+/-18.2 mmHg. The mean Qp/Qs ratio was 3.1+/-1.2. The mean ductus diameter was 3.3+/-0.8 mm. ADO was successfully deployed in 45 patients. Failure occurred in 1 case. The mean diameter of device used was 5.4+/-1.1 mm. No severe complications occurred. At the 1-month echocardiographic follow-up, a small residual shunt was present in 4 of 45 patients and had disappeared in all 4 patients at the 3-month follow-up. One patient developed a moderate degree of left ventricular outflow tract obstruction 2.3 years after the procedure. Transcatheter closure of PDA in infants using the ADO is a safe and effective method.

  8. NEOWISE Reactivation Mission Year Three: Asteroid Diameters and Albedos

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Masiero, Joseph R.; Mainzer, A. K.; Kramer, E.

    The Near-Earth Object Wide-field Infrared Survey Explorer (NEOWISE) reactivation mission has completed its third year of surveying the sky in the thermal infrared for near-Earth asteroids and comets. NEOWISE collects simultaneous observations at 3.4 and 4.6  μ m of solar system objects passing through its field of regard. These data allow for the determination of total thermal emission from bodies in the inner solar system, and thus the sizes of these objects. In this paper, we present thermal model fits of asteroid diameters for 170 NEOs and 6110 Main Belt asteroids (MBAs) detected during the third year of the survey,more » as well as the associated optical geometric albedos. We compare our results with previous thermal model results from NEOWISE for overlapping sample sets, as well as diameters determined through other independent methods, and find that our diameter measurements for NEOs agree to within 26% (1 σ ) of previously measured values. Diameters for the MBAs are within 17% (1 σ ). This brings the total number of unique near-Earth objects characterized by the NEOWISE survey to 541, surpassing the number observed during the fully cryogenic mission in 2010.« less

  9. Left Atrium Size in Elite Athletes.

    PubMed

    Iskandar, Aline; Mujtaba, Mohammad Tokir; Thompson, Paul D

    2015-07-01

    The goal of this study was to perform a meta-analysis of the published literature to investigate the relationship of high levels of exercise training to left atrial (LA) size. The "athlete's heart" is a series of cardiac adaptations to systematic exercise training and may include LA enlargement. We conducted a systematic review of English-language studies in MEDLINE and Scopus from inception through April 29, 2014, that reported LA size in elite athletes. A total of 54 studies comprising 7,189 elite athletes and 1,375 controls were included. Forty-eight of the 54 studies reported absolute LA diameter in 7,018 athletes and 1,044 controls. Nine of the 54 studies (including 992 athletes and 426 controls) presented LA volume corrected for body surface area. The adjusted weighted mean LA diameter was 4.1 mm greater in athletes overall compared with sedentary controls (p < 0.0001), and LA volume index was 7.0 ml/m(2) greater in athletes than controls (p < 0.01). Compared with controls, LA diameter was 4.6 mm greater in endurance-trained athletes (p < 0.0001), 2.9 mm greater in strength-trained athletes (p < 0.03), 3.5 mm greater in combined strength- and endurance-trained athletes (p < 0.0001), and 4.2 mm greater in athletes with unspecified training (p < 0.02). To our knowledge, this is the largest compilation of studies documenting that elite athletes have larger LA dimensions compared with controls when evaluated by either LA diameter or LA volume corrected for body surface area. The largest average LA diameters were reported in endurance athletes. Physicians evaluating athletes should be aware that the LA is increased in both strength- and endurance-trained elite athletes. Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  10. Performance Evaluation and Initial Clinical Test of the Positron Emission Mammography System (PEMi)

    NASA Astrophysics Data System (ADS)

    Li, Lin; Gu, Xiao-Yue; Li, Dao-Wu; Huang, Xian-Chao; Chai, Pei; Feng, Bao-Tong; Wang, Pei-Lin; Yun, Ming-Kai; Dai, Dong; Zhang, Zhi-Ming; Yin, Peng-Fei; Xu, Wen-Gui; Wei, Long

    2015-10-01

    A new polygon positron emission mammography imaging system (PEMi) was developed in 2009 by the Institute of High Energy Physics, Chinese Academy of Sciences. PEMi is constructed in a polygon structure with lutetium yttrium orthosilicate crystal arrays mounted on a position-sensitive photomultiplier. The system consists of 64 blocks and each block is arranged in 16 ×16 crystal arrays with a pixel size of 1.9 ×1.9 ×15 mm. The diameter of the detector ring is 166 mm, and the axial length is 128 mm. The transaxial field of view of PEMi is 110 mm. The goal of the initial study was to test PEMi's performance and the clinical imaging ability with a small group of selected subjects. The detectors have a measured intrinsic spatial resolution averaging 1.67 mm. The axial and tangential resolution remained under 2.5-mm full width at half maximum within the central 5-cm diameter of the field of view. The hot rods with a diameter of 1.7 mm can be clearly identified, and the structure of the region containing 1.35-mm diameter rods can also be observed. Using a 6-ns coincidence timing window and a 360 660-keV energy window, the peak sensitivity of the tomograph is 6.88%. The noise-equivalent count rate peak is 110 766 cps for a breast-like cylindrical phantom of 100 mm in diameter at an activity concentration of 0.03 MBq/cc. The recovery coefficients ranged from 0.21 to 0.85 for rods between 1 mm and 5 mm in the image-quality phantom. The reconstructed image resolution achieved an improvement compared with whole-body positron emission tomography (PET), which might reduce the lower threshold on detectable lesion size. Example patient images demonstrate that PEMi is clinically feasible. And more detailed structure information was obtained with PEMi than with the whole-body PET imaging.

  11. 29 CFR 452.123 - Elections of intermediate body officers.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... 29 Labor 2 2011-07-01 2011-07-01 false Elections of intermediate body officers. 452.123 Section... intermediate body officers. Section 401(d) states that officers of intermediate bodies shall be elected either... intermediate bodies. Such delegates may therefore participate in the election of officers of intermediate...

  12. 29 CFR 452.123 - Elections of intermediate body officers.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 29 Labor 2 2010-07-01 2010-07-01 false Elections of intermediate body officers. 452.123 Section... intermediate body officers. Section 401(d) states that officers of intermediate bodies shall be elected either... intermediate bodies. Such delegates may therefore participate in the election of officers of intermediate...

  13. Macrosegregation in Al-7Si alloy caused by abrupt cross-section change during directional solidification

    NASA Astrophysics Data System (ADS)

    Ghods, M.; Johnson, L.; Lauer, M.; Grugel, R. N.; Tewari, S. N.; Poirier, D. R.

    2016-09-01

    Hypoeutectic Al-7 wt .% Si alloys were directionally solidified vertically downward in cylindrical molds that incorporated an abrupt cross-section decrease (9.5 mm to 3.2 mm diameter) which, after 5 cm, reverted back to 9.5 mm diameter in a Bridgman furnace; two constant growth speeds and thermal gradients were investigated. Thermosolutal convection and cross-section-change-induced shrinkage flow effects on macrosegregation were investigated. Dendrite clustering and extensive radial macrosegregation was seen, particularly in the larger cross-sections, before contraction and after expansion, this more evident at the lower growth speed. This alloy shows positive longitudinal macrosegregation near cross-section decrease followed by negative macrosegregation right after it; the extent of macrosegregation, however, decreases with increasing growth speed. Primary dendrite steepling intensified as solidification proceeded into the narrower section and negative longitudinal macrosegregation was seen on the re-entrant shelves at expansion. A two-dimensional model accounting for both shrinkage and thermo-solutal convection was used to simulate solidification and the resulting mushy-zone steepling and macrosegregation. The experimentally observed longitudinal and radial macrosegregation associated with the cross-section changes during directional solidification of an Al-7Si alloy is well captured by the numerical simulations.

  14. Article comprising a garment or other textile structure for use in controlling body temperature

    DOEpatents

    Butzer, Melissa J.

    2000-01-01

    There is disclosed an article for use in cooling body temperature which comprises a garment having a coat and pant, with each having a body section adapted to receive a portion of the torso of the wearer and extensions from the body section to receive the wearer's limbs. The garment includes a system for circulating temperature controlling fluid from a suitable source through patches removably received in pockets in each of body section and extensions.

  15. Heat Transfer to Bodies in a High-speed Rarified-Gas Stream

    NASA Technical Reports Server (NTRS)

    Stalder, Jackson R; Goodwin, Glen; Creager, Marcus O

    1952-01-01

    Report presents the results of an investigation to determine the equilibrium temperature and heat-transfer coefficients for transverse cylinders in a high-speed stream of rarefied gas measured over a range of Knudsen numbers (ratio of molecular-mean-free path to cylinder diameter) from 0.025 to 11.8 and for Mach numbers from 2.0 to 3.3. The range of free-stream Reynolds numbers was from 0.28 to 203. The models tested were 0.0010-, 0.0050-, 0.030-, 0.051-, 0.080-, and 0.126-inch -diameter cylinders held normal to the stream.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lamoureux, R; Sinclair, L; Mench, A

    Purpose: To introduce and investigate effective diameter ratios as a new patient metric for use in computed tomography protocol selection as a supplement to patient-specific size parameter data. Methods: The metrics of outer effective diameter and inner effective diameter were measured for 7 post-mortem subjects scanned with a standardized chest/abdomen/pelvis (CAP) protocol on a 320-slice MDCT scanner. The outer effective diameter was calculated by obtaining the anterior/posterior and lateral dimensions of the imaged anatomy at the middle of the scan range using Effective Diameter= SQRT(AP height*Lat Width). The inner effective diameter was calculated with the same equation using the APmore » and Lat dimensions of the anatomy excluding the adipose tissue. The ratio of outer to inner effective diameter was calculated for each subject. A relationship to BMI, weight, and CTDI conversion coefficients was investigated. Results: For the largest subject with BMI of 43.85 kg/m2 and weight of 255 lbs the diameter ratio was calculated as 1.33. For the second largest subject with BMI of 33.5 kg/m2 and weight of 192.4 lbs the diameter ratio was measured as 1.43, indicating a larger percentage of adipose tissue in the second largest subject’s anatomical composition. For the smallest subject at BMI of 17.4 kg/m2 and weight of 86 lbs a similar tissue composition was indicated as a subject with BMI of 24.2 kg/m2 and weight of 136 lbs as they had the same diameter ratios of 1.11. Conclusion: The diameter ratio proves to contain information about anatomical composition that the BMI and weight alone do not. The utility of this metric is still being examined but could prove useful for determining MDCT techniques and for giving a more in depth detail of the composition of a patient’s body habitus.« less

  17. Combined experimental and numerical investigation of energy harness utilizing vortex induced vibration over half cylinder using piezoelectric beams

    NASA Astrophysics Data System (ADS)

    Ahmed, Md. Tusher; Hossain, Md. Tanver; Rahman, Md. Ashiqur

    2017-06-01

    Energy harvesting technology has the ability to create self-powered electronic systems that do not rely on battery power for their operation. Wind energy can be converted into electricity via a piezoelectric transducer during the air flow over a cylinder. The vortex-induced vibration over the cylinder causes the piezoelectric beam to vibrate. Thus useful electric energy at the range 0.2-0.3V is found which can be useful for self-powering small electronic devices. In the present study, prototypes of micro-energy harvester with a shape of 65 mm × 37 mm × 0.4 mm are developed and tested for airflow over D-shaped bluff body for diameters of 15, 20 and 28mm in an experimental setup consisting of a long wind tunnel of 57cm × 57cm with variable speeds of the motor for different flow velocities and the experimental setup is connected at the downstream where flow velocity is the maximum. Experimental results show that the velocity and induced voltage follows a regular linear pattern. A maximum electrical potential of 140 mV for velocity of 1.1 ms-1 at a bluff body diameter of 15 mm is observed in the energy harvester that can be applied in many practical cases for self-powering electronic devices. The simulation of this energy harvesting phenomena is then simulated using COMSOLE multi-physics. Diameter of the bluff bodies as well as flow velocity and size of cantilever beam are varied and the experimental findings are found to be in good agreement with the simulated ones. The simulations along with the experimental data show the possibility of generating electricity from vortex induced vibration and can be applied in many practical cases for self-powering electronic devices.

  18. One new genus and three new species of deep-sea nematodes (Nematoda: Microlaimidae) from the Southwest Pacific Ocean and Ross Sea.

    PubMed

    Leduc, Daniel

    2016-02-11

    New deep-sea nematodes of the family Microlaimidae are described from the Southwest Pacific Ocean and Ross Sea. Microlaimus korari n. sp. is characterised by annulated cuticle with longitudinal bars, round amphideal aperture slightly smaller than the cryptospiral amphideal fovea, spacious and heavily cuticularised buccal cavity with large dorsal tooth and right subventral tooth situated anteriorly relative to left subventral tooth, slender spicules 4.4 cloacal body diameters long, and gubernaculum 1.2 cloacal body diameters long with laterally curved distal end and swollen proximal end. Bolbolaimus tongaensis n. sp. is characterised by annulated cuticle with longitudinal bars, oval amphideal aperture and cryptocircular amphideal fovea situated between cephalic setae and only partially surrounded by cuticle annulations, and short spicules cuticularised along dorsal edge and at proximal end and with swollen portion near proximal end. Maragnopsia n. gen. is characterised by a minute, non-cuticularised mouth cavity without teeth, an elongated posterior pharyngeal bulb more than twice as long as it is wide, a single outstretched testis, and a conico-cylindrical tail 13-16 anal body diameters long. A list of all 83 valid Microlaimus species is provided. The present study provides the first microlaimid species records from deep-sea habitats (> 200 m depth) in the Southwest Pacific and Ross Sea. The presence of M. korari n. sp. on both the continental slope of New Zealand and Ross Sea abyssal plain suggests that this species has a wide geographical and depth distribution. However, molecular analyses will be required to confirm the identity of these two geographically disparate populations.

  19. Ex vivo magnetic resonance imaging of crystalline lens dimensions in chicken.

    PubMed

    Tattersall, Rebecca J; Prashar, Ankush; Singh, Krish D; Tokarczuk, Pawel F; Erichsen, Jonathan T; Hocking, Paul M; Guggenheim, Jeremy A

    2010-02-02

    A reduction in the power of the crystalline lens during childhood is thought to be important in the emmetropization of the maturing eye. However, in humans and model organisms, little is known about the factors that determine the dimensions of the crystalline lens and in particular whether these different parameters (axial thickness, surface curvatures, equatorial diameter, and volume) are under a common source of control or regulated independently of other aspects of eye size and shape. Using chickens from a broiler-layer experimental cross as a model system, three-dimensional magnetic resonance imaging (MRI) scans were obtained at 115-microm isotropic resolution for one eye of 501 individuals aged 3-weeks old. After fixation with paraformaldehyde, the excised eyes were scanned overnight (16 h) in groups of 16 arranged in a 2x2x4 array. Lens dimensions were calculated from each image by fitting a three-dimensional mesh model to the lens, using the semi-automated analysis program mri3dX. The lens dimensions were compared to measures of eye and body size obtained in vivo using techniques that included keratometry and A-scan ultrasonography. A striking finding was that axial lens thickness measured using ex vivo MRI was only weakly correlated with lens thickness measured in vivo by ultrasonography (r=0.19, p<0.001). In addition, the MRI lens thickness estimates had a lower mean value and much higher variance. Indeed, about one-third of crystalline lenses showed a kidney-shaped appearance instead of the typical biconvex shape. Since repeat MRI scans of the same eye showed a high degree of reproducibility for the scanning and mri3dX analysis steps (the correlation in repeat lens thickness measurements was r=0.95, p<0.001) and a recent report has shown that paraformaldehyde fixation induces a loss of water from the human crystalline lens, it is likely that the tissue fixation step caused a variable degree of shrinkage and a change in shape to the lenses examined here. Despite this serious source of imprecision, we found significant correlations between lens volume and eye/body size (p<0.001) and between lens equatorial diameter and eye/body size (p<0.001) in these chickens. Our results suggest that certain aspects of lens size (specifically, lens volume and equatorial diameter) are controlled by factors that also regulate the size of the eye and body (presumably, predominantly genetic factors). However, since it has been shown previously that axial lens thickness is regulated almost independently of eye and body size, these results suggest that different systems might operate to control lens volume/diameter and lens thickness in normal chickens.

  20. Ex vivo magnetic resonance imaging of crystalline lens dimensions in chicken

    PubMed Central

    Tattersall, Rebecca J.; Prashar, Ankush; Singh, Krish D.; Tokarczuk, Pawel F.; Erichsen, Jonathan T.; Hocking, Paul M.

    2010-01-01

    Purpose A reduction in the power of the crystalline lens during childhood is thought to be important in the emmetropization of the maturing eye. However, in humans and model organisms, little is known about the factors that determine the dimensions of the crystalline lens and in particular whether these different parameters (axial thickness, surface curvatures, equatorial diameter, and volume) are under a common source of control or regulated independently of other aspects of eye size and shape. Methods Using chickens from a broiler-layer experimental cross as a model system, three-dimensional magnetic resonance imaging (MRI) scans were obtained at 115-µm isotropic resolution for one eye of 501 individuals aged 3-weeks old. After fixation with paraformaldehyde, the excised eyes were scanned overnight (16 h) in groups of 16 arranged in a 2×2×4 array. Lens dimensions were calculated from each image by fitting a three-dimensional mesh model to the lens, using the semi-automated analysis program mri3dX. The lens dimensions were compared to measures of eye and body size obtained in vivo using techniques that included keratometry and A-scan ultrasonography. Results A striking finding was that axial lens thickness measured using ex vivo MRI was only weakly correlated with lens thickness measured in vivo by ultrasonography (r=0.19, p<0.001). In addition, the MRI lens thickness estimates had a lower mean value and much higher variance. Indeed, about one-third of crystalline lenses showed a kidney-shaped appearance instead of the typical biconvex shape. Since repeat MRI scans of the same eye showed a high degree of reproducibility for the scanning and mri3dX analysis steps (the correlation in repeat lens thickness measurements was r=0.95, p<0.001) and a recent report has shown that paraformaldehyde fixation induces a loss of water from the human crystalline lens, it is likely that the tissue fixation step caused a variable degree of shrinkage and a change in shape to the lenses examined here. Despite this serious source of imprecision, we found significant correlations between lens volume and eye/body size (p<0.001) and between lens equatorial diameter and eye/body size (p<0.001) in these chickens. Conclusions Our results suggest that certain aspects of lens size (specifically, lens volume and equatorial diameter) are controlled by factors that also regulate the size of the eye and body (presumably, predominantly genetic factors). However, since it has been shown previously that axial lens thickness is regulated almost independently of eye and body size, these results suggest that different systems might operate to control lens volume/diameter and lens thickness in normal chickens. PMID:20142845

  1. Influence of tempering and contraction mismatch on crack development in ceramic surfaces.

    PubMed

    Anusavice, K J; DeHoff, P H; Hojjatie, B; Gray, A

    1989-07-01

    Tempering of glass produces a state of compressive stress in surface regions which can enhance the resistance to crack initiation and growth. The objective of this study was to determine the influence of tempering on the sizes of surface cracks induced within the tempered surfaces of opaque porcelain-body porcelain discs, with contraction coefficient differences (alpha O-alpha B) of +3.2, +0.7, 0.0, -0.9, and -1.5 ppm/degrees C. We fired the discs to the maturing temperature (982 degrees C) of body porcelain and then subjected them to three cooling procedures: slow cooling in a furnace (SC), fast cooling in air (FC), and tempering (T) by blasting the body porcelain surface with compressed air for 90 s. We used body porcelain discs as the thermally compatible (delta alpha = 0) control specimens. We measured the diameters of cracks induced by a microhardness indenter at an applied load of 4.9 N at 80 points along diametral lines within the surface of body porcelain. The mean values of the crack diameters varied from 75.9 microns (delta alpha = -1.5 ppm/degrees C) to 103.3 microns (delta alpha = +3.2 ppm/degrees C). The results of ANOVA indicate that significant differences in crack dimensions were controlled by cooling rate, contraction mismatch, and their combined effect (p less than 0.0001). Multiple contrast analysis (Tukey's HSD Test) revealed significantly lower (p less than 0.05) crack sizes for tempered specimens compared with those of fast-cooled and slow-cooled specimens.(ABSTRACT TRUNCATED AT 250 WORDS)

  2. Transient dwarfism of soil fauna during the Paleocene–Eocene Thermal Maximum

    PubMed Central

    Smith, Jon J.; Hasiotis, Stephen T.; Kraus, Mary J.; Woody, Daniel T.

    2009-01-01

    Soil organisms, as recorded by trace fossils in paleosols of the Willwood Formation, Wyoming, show significant body-size reductions and increased abundances during the Paleocene–Eocene Thermal Maximum (PETM). Paleobotanical, paleopedologic, and oxygen isotope studies indicate high temperatures during the PETM and sharp declines in precipitation compared with late Paleocene estimates. Insect and oligochaete burrows increase in abundance during the PETM, suggesting longer periods of soil development and improved drainage conditions. Crayfish burrows and molluscan body fossils, abundant below and above the PETM interval, are significantly less abundant during the PETM, likely because of drier floodplain conditions and lower water tables. Burrow diameters of the most abundant ichnofossils are 30–46% smaller within the PETM interval. As burrow size is a proxy for body size, significant reductions in burrow diameter suggest that their tracemakers were smaller bodied. Smaller body sizes may have resulted from higher subsurface temperatures, lower soil moisture conditions, or nutritionally deficient vegetation in the high-CO2 atmosphere inferred for the PETM. Smaller soil fauna co-occur with dwarf mammal taxa during the PETM; thus, a common forcing mechanism may have selected for small size in both above- and below-ground terrestrial communities. We predict that soil fauna have already shown reductions in size over the last 150 years of increased atmospheric CO2 and surface temperatures or that they will exhibit this pattern over the next century. We retrodict also that soil fauna across the Permian-Triassic and Triassic-Jurassic boundary events show significant size decreases because of similar forcing mechanisms driven by rapid global warming. PMID:19805060

  3. Transient dwarfism of soil fauna during the Paleocene-Eocene Thermal Maximum.

    PubMed

    Smith, Jon J; Hasiotis, Stephen T; Kraus, Mary J; Woody, Daniel T

    2009-10-20

    Soil organisms, as recorded by trace fossils in paleosols of the Willwood Formation, Wyoming, show significant body-size reductions and increased abundances during the Paleocene-Eocene Thermal Maximum (PETM). Paleobotanical, paleopedologic, and oxygen isotope studies indicate high temperatures during the PETM and sharp declines in precipitation compared with late Paleocene estimates. Insect and oligochaete burrows increase in abundance during the PETM, suggesting longer periods of soil development and improved drainage conditions. Crayfish burrows and molluscan body fossils, abundant below and above the PETM interval, are significantly less abundant during the PETM, likely because of drier floodplain conditions and lower water tables. Burrow diameters of the most abundant ichnofossils are 30-46% smaller within the PETM interval. As burrow size is a proxy for body size, significant reductions in burrow diameter suggest that their tracemakers were smaller bodied. Smaller body sizes may have resulted from higher subsurface temperatures, lower soil moisture conditions, or nutritionally deficient vegetation in the high-CO(2) atmosphere inferred for the PETM. Smaller soil fauna co-occur with dwarf mammal taxa during the PETM; thus, a common forcing mechanism may have selected for small size in both above- and below-ground terrestrial communities. We predict that soil fauna have already shown reductions in size over the last 150 years of increased atmospheric CO(2) and surface temperatures or that they will exhibit this pattern over the next century. We retrodict also that soil fauna across the Permian-Triassic and Triassic-Jurassic boundary events show significant size decreases because of similar forcing mechanisms driven by rapid global warming.

  4. Transient dwarfism of soil fauna during the Paleocene-Eocene Thermal Maximum

    USGS Publications Warehouse

    Smith, J.J.; Hasiotis, S.T.; Kraus, M.J.; Woody, D.T.

    2009-01-01

    Soil organisms, as recorded by trace fossils in paleosols of the Willwood Formation, Wyoming, show significant body-size reductions and increased abundances during the Paleocene-Eocene Thermal Maximum (PETM). Paleobotanical, paleopedologic, and oxygen isotope studies indicate high temperatures during the PETM and sharp declines in precipitation compared with late Paleocene estimates. Insect and oligochaete burrows increase in abundance during the PETM, suggesting longer periods of soil development and improved drainage conditions. Crayfish burrows and molluscan body fossils, abundant below and above the PETM interval, are significantly less abundant during the PETM, likely because of drier floodplain conditions and lower water tables. Burrow diameters of the most abundant ichnofossils are 30-46% smaller within the PETM interval. As burrow size is a proxy for body size, significant reductions in burrow diameter suggest that their tracemakers were smaller bodied. Smaller body sizes may have resulted from higher subsurface temperatures, lower soil moisture conditions, or nutritionally deficient vegetation in the high-CO2 atmosphere inferred for the PETM. Smaller soil fauna co-occur with dwarf mammal taxa during the PETM; thus, a common forcing mechanism may have selected for small size in both above- and below-ground terrestrial communities. We predict that soil fauna have already shown reductions in size over the last 150 years of increased atmospheric CO2 and surface temperatures or that they will exhibit this pattern over the next century. We retrodict also that soil fauna across the Permian-Triassic and Triassic-Jurassic boundary events show significant size decreases because of similar forcing mechanisms driven by rapid global warming.

  5. Space Station

    NASA Image and Video Library

    1972-01-01

    This is an artist's concept of a modular space station. In 1970 the Marshall Space Flight Center arnounced the completion of a study concerning a modular space station that could be launched by the planned-for reusable Space Shuttle. The study envisioned a space station composed of cylindrical sections 14 feet in diameter and of varying lengths joined to form any one of a number of possible shapes. The sections were restricted to 14 feet in diameter and 58 feet in length to be consistent with a shuttle cargo bay size of 15 by 60 feet. Center officials said that the first elements of the space station could be in orbit by about 1978 and could be manned by three or six men. This would be an interim space station with sections that could be added later to form a full 12-man station by the early 1980s.

  6. Recent disruption of an asteroid from the Eos family

    NASA Astrophysics Data System (ADS)

    Novaković, B.; Tsirvoulis, G.

    2014-07-01

    A key difficulty with searching for partially differentiated asteroids arises from the fact that a crust covers the exterior of the body, and, consequently, should hide the melted interior. This motivates an alternative approach of examining members of asteroid families, i.e., fragments of single large bodies, many of which were in the size regime capable of igneous differentiation, that have been disrupted by catastrophic collisions. Such families could provide a stratigraphic cross section across the interior of the parent asteroid [1]. With more than 10,000 known members, the Eos dynamical family is one of the most numerous and earliest recognized asteroid families [2]. Interestingly, the estimated ˜220-km-diameter parent body [3] is well within the size range capable of differentiation. Thus, existing family members should contain fragments of the deep interior. The Eos family has the highest diversity of taxonomic classes than any other known family [4]. Many members are of K spectral type, which is uncommon outside the family, and is similar to the spectra of CV, CK, CO, and CR carbonaceous chondrites [5]. This diversity leads to the suggestion that the Eos parent body was partially differentiated [4,6]. Thus, the Eos family may not only be a remnant of a partially differentiated parent body, but it could be the source of the CV-CK meteorite group. Here we report the discovery of a young subfamily of the Eos asteroid family. It may help understanding the mineralogical nature of the Eos asteroid family and of its parent body. By applying the hierarchical clustering method [7], we find an extremely compact 16-body cluster within the borders of the Eos family. We name the cluster (6733) 1992 EF, after its largest member. The statistical significance of this new cluster is estimated to be above 99%, indicating that its members share a common origin. All members of the cluster are found to be dynamically stable over long timescales. Backward numerical orbital integrations are used to set an upper limit of the age of the cluster to be only 4 Myr.

  7. Fabrication of precision glass shells by joining glass rods

    DOEpatents

    Gac, Frank D.; Blake, Rodger D.; Day, Delbert E.; Haggerty, John S.

    1988-01-01

    A method for making uniform spherical shells. The present invention allows niform hollow spheres to be made by first making a void in a body of material. The material is heated so that the viscosity is sufficiently low so that the surface tension will transform the void into a bubble. The bubble is allowed to rise in the body until it is spherical. The excess material is removed from around the void to form a spherical shell with a uniform outside diameter.

  8. Poly(A) RNA a new component of Cajal bodies.

    PubMed

    Kołowerzo, Agnieszka; Smoliński, Dariusz Jan; Bednarska, Elzbieta

    2009-07-01

    In European larch microsporocytes, spherical structures 0.5 to 6 microm in diameter are present in which poly(A) RNA accumulates. There were one to several bodies per cell and they were often present in the vicinity of the nucleolus. No nascent transcripts were observed within them. Splicing factors of the SR family, including protein SC35, which participates in bringing the 3' and 5' sites closer in the splicing reaction, were also not observed. The absence of the above-mentioned elements within bodies containing poly(A) RNA disqualifies them as sites of synthesis and preliminary stages of primary transcript maturation. However, they contained abundant elements of the splicing machinery commonly occurring in Cajal bodies, i.e., Sm proteins or small nuclear RNA (snRNA). The molecular composition as well as the characteristic ultrastructure of bodies containing poly(A) RNA proves that these were Cajal bodies. This is the first report of such poly(A) RNA localization.

  9. Modeling the non-grey-body thermal emission from the full moon

    NASA Technical Reports Server (NTRS)

    Vogler, Karl J.; Johnson, Paul E.; Shorthill, Richard W.

    1991-01-01

    The present series of thermophysical computer models for solid-surfaced planetary bodies whose surface roughness is modeled as paraboloidal craters of specified depth/diameter ratio attempts to characterize the nongrey-body brightness temperature spectra of the moon and of the Galilean satellites. This modeling, in which nondiffuse radiation properties and surface roughness are included for rigorous analysis of scattered and reemitted radiation within a crater, explains to first order the behavior of both limb-scans and disk-integrated IR brightness temperature spectra for the full moon. Only negative surface relief can explain lunar thermal emissions' deviation from smooth Lambert-surface expectations.

  10. Detonation propagation in a high loss configuration

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jackson, Scott I; Shepherd, Joseph E

    2009-01-01

    This work presents an experimental study of detonation wave propagation in tubes with inner diameters (ID) comparable to the mixture cell size. Propane-oxygen mixtures were used in two test section tubes with inner diameters of 1.27 mm and 6.35 mm. For both test sections, the initial pressure of stoichiometric mixtures was varied to determine the effect on detonation propagation. For the 6.35 mm tube, the equivalence ratio {phi} (where the mixture was {phi} C{sub 3}H{sub 8} + 50{sub 2}) was also varied. Detonations were found to propagate in mixtures with cell sizes as large as five times the diameter ofmore » the tube. However, under these conditions, significant losses were observed, resulting in wave propagation velocities as slow as 40% of the CJ velocity U{sub CJ}. A review of relevant literature is presented, followed by experimental details and data. Observed velocity deficits are predicted using models that account for boundary layer growth inside detonation waves.« less

  11. Experimental and numerical study of the effect of rolling parameters on shaft deformation during the longitudinal rolling process

    NASA Astrophysics Data System (ADS)

    Kowalik, Marek; Trzepiecinski, Tomasz

    2018-05-01

    This paper presents the characteristics of the process of longitudinal rolling of shafts and the geometry of the working section of forming rollers with a secant profile. In addition, the analytical formulae defining the geometry of a roller profile were determined. The experiments were carried out on shafts made of S235JR and C45 structural steels and the MSC.Marc + Mentat program was used for the numerical analysis of the rolling process based on the finite element method. The paper analyses the effect of roller geometry on the changes in value of the widening coefficient and the diameter reduction coefficient for the first forming passage. It was found that the mechanical properties of the shaft material have a slight influence on the widening coefficient. The value of the widening coefficient of the shaft increases with increase in the initial diameter of the shaft. Increasing shaft diameter causes an increase of strain gradient on the cross-section of the shaft.

  12. Laboratory experiments of crater formation on ice-rock mixture targets

    NASA Astrophysics Data System (ADS)

    Hiraoka, K.; Arakawa, M.; Yoshikawa, K.; Nakamura, A. M.

    Surfaces of ice-rock mixture are common among planetary bodies in outer solar system, such as the satellites of the giant planets, comet nuclei, and so on. In order to study the effect of the presence of volatiles in crater formation on these bodies, we performed impact experiments using a two-stage light-gas gun and a gas gun at Hokkaido University. The targets were ice-rock mixtures (diameter = 10 or 30cm, height = 5cm) with 0 wt.% to 50 wt.% rock. Projectiles were ice cylinders (diameter = 15mm, height = 10mm) or corn-shaped nylon ones and the impact velocities were varied from about 300m/s to 3500m/s. We will show an anti-correlation between the crater volume and the rock content, and will make a comparison with previous works (Lange and Ahrens 1982; Koschny and Grun 2001). Ejecta size and velocity measured on high-speed video images will be presented and will be discussed by a comparison with a spallation model (Melosh 1984).

  13. Test Report for MSFC Test No. 83-2: Pressure scaled water impact test of a 12.5 inch diameter model of the Space Shuttle solid rocket booster filament wound case and external TVC PCD

    NASA Technical Reports Server (NTRS)

    1983-01-01

    Water impact tests using a 12.5 inch diameter model representing a 8.56 percent scale of the Space Shuttle Solid Rocket Booster configuration were conducted. The two primary objectives of this SRB scale model water impact test program were: 1. Obtain cavity collapse applied pressure distributions for the 8.56 percent rigid body scale model FWC pressure magnitudes as a function of full-scale initial impact conditions at vertical velocities from 65 to 85 ft/sec, horizontal velocities from 0 to 45 ft/sec, and angles from -10 to +10 degrees. 2. Obtain rigid body applied pressures on the TVC pod and aft skirt internal stiffener rings at initial impact and cavity collapse loading events. In addition, nozzle loads were measured. Full scale vertical velocities of 65 to 85 ft/sec, horizontal velocities of 0 to 45 ft/sec, and impact angles from -10 to +10 degrees simulated.

  14. [Dynamic forces of Mitkovic self-dinamysible trochanteric Internal fixators (SIF)].

    PubMed

    Mitković, Milan M; Manić, Miodrag T; Petković, Dusan Lj; Milenković, Sasa S; Mitković, Milorad B

    2013-01-01

    Dynamic trochanteric fractures implants allow fracture fragments to be compressed. Dynamisation can be realized if the axial pin force overcome friction force between pin and body of the implant. Examination of sliding iniciation forces in Mitkovic Selfdinamysible Trochanteric Internal Fixator (SIF). SIF was attached for angle block in the position with vertical orientation of pins. The transversal load of 5 kg was connected to pins by a rope. A dynamometer was used to measure force during the movement of angle block in up direction. Regression coefficients were a1 = 4,052 i b1 = 0,623 for SIF with 2 sliding screws with diameter of 7mm and a2 = 4,534 i b2 = 0,422 for SIF with 1 screw with diameter of 10 mm. Coefficients of determination were: r12 = 0,470 and r22 = 0,123. Sliding of SIF pins can be achieved for each analysed body weight of patient (50-130 kg). Early bearing of operated leg is significant for sliding initiation of SIF sliding screws.

  15. Dynamical Evolution of Asteroids and Meteoroids Using the Yarkovsky Effect

    NASA Technical Reports Server (NTRS)

    Bottke, William F., Jr.; Vokrouhlicky, David; Rubincam, David P.; Broz, Miroslav; Smith, David E. (Technical Monitor)

    2001-01-01

    The Yarkovsky effect is a thermal radiation force which causes objects to undergo semimajor axis drift and spin up/down as a function of their spin, orbit, and material properties. This mechanism can be used to (i) deliver asteroids (and meteoroids) with diameter D < 20 km from their parent bodies in the main belt to chaotic resonance zones capable of transporting this material to Earth-crossing orbits, (ii) disperse asteroid families, with drifting bodies jumping or becoming trapped in mean-motion and secular resonances within the main belt, and (iii) modify the rotation rates of asteroids a few km in diameter or smaller enough to explain the excessive number of very fast and very slow rotators among the small asteroids. Accordingly, we suggest that nongravitational forces, which produce small but meaningful effects on asteroid orbits and rotation rates over long timescales, should now be considered as important as collisions and gravitational perturbations to our overall understanding of asteroid evolution.

  16. Disrupting effects of polychlorinated biphenyls on gonadal development and reproductive functions in chickens.

    PubMed

    Zhang, Caiqiao; Fang, Changge; Liu, Li; Xia, Guoliang; Qiao, Huili

    2002-01-01

    Polychlorinated biphenyls (PCBs) are worldwide persistent pollutants that have produced detrimental effects on endocrine function and reproduction in a variety of species. The present study revealed effects of PCBs on gonadal development and functions in chickens of different ages. Aroclor 1254 (0-100 microg/egg) was injected into Hyline chicken eggs before incubation. The adult chickens received Aroclor 1254 by gavage (50 mg/kg BW). It was observed that in day 5 embryos, PCBs resulted in a dose-dependent decrease of primordial germ cell (PGC) numbers, and caused PGCs pyknosis and vacuolation. Clomiphen failed to block the effects of PCBs. In the newly hatched chicken, PCBs induced a marked decrease in area of the transverse sections, diameter and relative area of the testicular tubules. The differentiation of germ cells was retarded after PCB treatment. In contrast, the area of the left ovarian transverse sections, the thickness of ovarian cortex and the number of oocytes increased dramatically in the female chickens after PCB exposure. In the adult chickens, PCBs caused no significant changes in body weight, respiration, heart rate, body temperature, red and white blood cell number, but induced a marked decrease in the testicular weight, and severe damage of the seminiferous tubules. The number of the spermatogenic cells and serum testosterone level were decreased significantly by PCBs. On the contrary, in the laying hens there was no significant effect of PCB on egg quality except a slight decrease in egg weight. These results indicated that PCBs exerted its disrupting effects on chicken reproduction with a sex and stage-related pattern, and in vivo disruption of gonadal development represents a possible model for risk assessment of environmental endocrine disrupters by in ovo treatment.

  17. Assessment of pelvic floor muscle contraction with palpation, perineometry and transperineal ultrasound: a cross-sectional study.

    PubMed

    Volløyhaug, I; Mørkved, S; Salvesen, Ø; Salvesen, K Å

    2016-06-01

    To study the correlation between palpation, perineometry and transperineal ultrasound for assessment of pelvic floor muscle contraction and to define a contraction scale for ultrasound measurements. This was a cross-sectional study of 608 women examined with palpation of pelvic floor muscle contraction, using the Modified Oxford Scale, and measurement of the vaginal squeeze pressure with a vaginal balloon connected to a fiber-optic microtip transducer (perineometry). Transperineal ultrasound was used for measurements of levator hiatal area and anteroposterior (AP) diameter in the plane of minimal hiatal dimensions, at rest and on contraction. The pelvic floor muscle contraction was expressed as the percentage difference between values at rest and on contraction. Spearman's rank was used to test for correlation between the different methods of assessment. Significant correlations were found between all assessment methods (P < 0.001). Palpation correlated with perineometry (rs = 0.74) and with proportional change in hiatal area (rs = 0.67) and AP diameter (rs = 0.69) on ultrasound. Perineometry correlated with proportional change in hiatal area (rs = 0.60) and AP diameter (rs = 0.66) on ultrasound. We defined a contraction scale based on the proportional change in AP diameter. In this population, a change in AP diameter of < 7% corresponded to absence of contractions, 7-18% corresponded to weak contractions, 18-35% corresponded to normal contractions and > 35% corresponded to strong contractions. We found moderate to strong correlation between ultrasound measurements, palpation and perineometry for assessing pelvic floor muscle contraction. The proportional change in levator hiatal AP diameter was the ultrasound measurement with strongest correlation to palpation and perineometry and formed the basis for the contraction scale for ultrasound measurements. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd. Copyright © 2015 ISUOG. Published by John Wiley & Sons Ltd.

  18. A scaling law for accretion zone sizes

    NASA Technical Reports Server (NTRS)

    Greenzweig, Yuval; Lissauer, Jack J.

    1987-01-01

    Current theories of runaway planetary accretion require small random velocities of the accreted particles. Two body gravitational accretion cross sections which ignore tidal perturbations of the Sun are not valid for the slow encounters which occur at low relative velocities. Wetherill and Cox have studied accretion cross sections for rocky protoplanets orbiting at 1 AU. Using analytic methods based on Hill's lunar theory, one can scale these results for protoplanets that occupy the same fraction of their Hill sphere as does a rocky body at 1 AU. Generalization to bodies of different sizes is achieved here by numerical integrations of the three-body problem. Starting at initial positions far from the accreting body, test particles are allowed to encounter the body once, and the cross section is computed. A power law is found relating the cross section to the radius of the accreting body (of fixed mass).

  19. Optical fiber cable chemical stripping fixture

    NASA Technical Reports Server (NTRS)

    Kolasinski, John R. (Inventor); Coleman, Alexander M. (Inventor)

    1995-01-01

    An elongated fixture handle member is connected to a fixture body member with both members having interconnecting longitudinal central axial bores for the passage of an optical cable therethrough. The axial bore of the fixture body member, however, terminates in a shoulder stop for the outer end of a jacket of the optical cable covering both an optical fiber and a coating therefor, with an axial bore of reduced diameter continuing from the shoulder stop forward for a predetermined desired length to the outer end of the fixture body member. A subsequent insertion of the fixture body member including the above optical fiber elements into a chemical stripping solution results in a softening of the exposed external coating thereat which permits easy removal thereof from the optical fiber while leaving a desired length coated fiber intact within the fixture body member.

  20. A prosthesis for banding the main pulmonary artery, capable of serial dilatation by balloon angioplasty.

    PubMed

    Vince, D J; Culham, J A

    1989-03-01

    A prosthesis constructed with a fatigued steel helix encased in a silicone rubber shield was used to band the main pulmonary artery in 10 dogs. After a mean duration of 138 days the banded site was dilated with a 20 mm diameter angioplasty catheter. This dilatation produced a mean increase of 44.3% in the cross-sectional area. A further mean increase of 2.2% in the cross-sectional area was measured 137 days after the dilatation. In five uncomplicated experiments a second dilatation was performed with a 23 mm diameter angioplasty catheter after a mean interval of 140 days. The second dilatation produced a further 21% increase in the cross-sectional area. In the five experiments in which two dilatations were performed, there was a total increase in the mean cross-sectional area of 94% produced 273 days after banding. This prosthesis maintains banding of the main pulmonary artery and can be serially dilated by balloon angioplasty.

  1. Muscular development and lean body weight in body builders and weight lifters.

    PubMed

    Katch, V L; Katch, F I; Moffatt, R; Gittleson, M

    1980-01-01

    The extent of extreme muscular development in 39 males identified as body builders (N = 18), power weight lifters (N = 13), and Olympic weight lifters (N = 8) were studied. Body composition and anthropometric data, including calculations of pre-excess muscle body weight (scale weight minus excess muscle) were obtained. The lean body weight and percent fats of the subjects were: body builders = 74.6 kg, 9.3%; power weight lifters = 73.3 kg, 9.1%; and Olympic weight lifters = 68.2 kg, 10.8%. No group differences were present in frame size, percent fat, lean body weight, skinfolds, and diameter measurements. The only group differences were for the shoulders, chest, biceps relaxed and flexed, and forearm girths. In each case the body builders were larger. Calculations of excess muscle by the Behnke method revealed that the body builders had 15.6 kg excess muscle, power weight lifters 14.8 kg, and Olympic weight lifters 13.1 kg. Somatographic comparisons revealed only slight differences between the groups, while differences with reference man were substantial.

  2. Measurement of Two-Phase Flow Characteristics Under Microgravity Conditions

    NASA Technical Reports Server (NTRS)

    Keshock, E. G.; Lin, C. S.; Edwards, L. G.; Knapp, J.; Harrison, M. E.; Xhang, X.

    1999-01-01

    This paper describes the technical approach and initial results of a test program for studying two-phase annular flow under the simulated microgravity conditions of KC-135 aircraft flights. A helical coil flow channel orientation was utilized in order to circumvent the restrictions normally associated with drop tower or aircraft flight tests with respect to two-phase flow, namely spatial restrictions preventing channel lengths of sufficient size to accurately measure pressure drops. Additionally, the helical coil geometry is of interest in itself, considering that operating in a microgravity environment vastly simplifies the two-phase flows occurring in coiled flow channels under 1-g conditions for virtually any orientation. Pressure drop measurements were made across four stainless steel coil test sections, having a range of inside tube diameters (0.95 to 1.9 cm), coil diameters (25 - 50 cm), and length-to-diameter ratios (380 - 720). High-speed video photographic flow observations were made in the transparent straight sections immediately preceding and following the coil test sections. A transparent coil of tygon tubing of 1.9 cm inside diameter was also used to obtain flow visualization information within the coil itself. Initial test data has been obtained from one set of KC-135 flight tests, along with benchmark ground tests. Preliminary results appear to indicate that accurate pressure drop data is obtainable using a helical coil geometry that may be related to straight channel flow behavior. Also, video photographic results appear to indicate that the observed slug-annular flow regime transitions agree quite reasonably with the Dukler microgravity map.

  3. Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis

    PubMed Central

    Georgiou, CS; Evangelou, KG; Theodorou, EG; Provatidis, CG; Megas, PD

    2012-01-01

    Due to their theoretical advantages, hip systems combining modular necks and large diameter femoral heads have gradually gained popularity. However, among others, concerns regarding changes in the load transfer patterns were raised. Recent stress analyses have indeed shown that the use of modular necks and big femoral heads causes significant changes in the strain distribution along the femur. Our original hypothesis was that these changes may affect early distal migration of a modular stem. We examined the effect of head diameter and neck geometry on migration at two years of follow-up in a case series of 116 patients (125 hips), who have undergone primary Metal-on-Metal total hip arthroplasty with the modular grit-blasted Profemur®E stem combined with large-diameter heads (>36 mm). We found that choice of neck geometry and head diameter has no effect on stem migration. A multivariate regression analysis including the potential confounding variables of the body mass index, bone quality, canal fill and stem positioning revealed only a negative correlation between subsidence and canal fill in midstem area. Statistical analysis, despite its limitations, did not confirm our hypothesis that choice of neck geometry and/or head diameter affects early distal migration of a modular stem. However, the importance of correct stem sizing was revealed. PMID:23284597

  4. Does Choice of Head Size and Neck Geometry Affect Stem Migration in Modular Large-Diameter Metal-on-Metal Total Hip Arthroplasty? A Preliminary Analysis.

    PubMed

    Georgiou, Cs; Evangelou, Kg; Theodorou, Eg; Provatidis, Cg; Megas, Pd

    2012-01-01

    Due to their theoretical advantages, hip systems combining modular necks and large diameter femoral heads have gradually gained popularity. However, among others, concerns regarding changes in the load transfer patterns were raised. Recent stress analyses have indeed shown that the use of modular necks and big femoral heads causes significant changes in the strain distribution along the femur. Our original hypothesis was that these changes may affect early distal migration of a modular stem. We examined the effect of head diameter and neck geometry on migration at two years of follow-up in a case series of 116 patients (125 hips), who have undergone primary Metal-on-Metal total hip arthroplasty with the modular grit-blasted Profemur®E stem combined with large-diameter heads (>36 mm). We found that choice of neck geometry and head diameter has no effect on stem migration. A multivariate regression analysis including the potential confounding variables of the body mass index, bone quality, canal fill and stem positioning revealed only a negative correlation between subsidence and canal fill in midstem area. Statistical analysis, despite its limitations, did not confirm our hypothesis that choice of neck geometry and/or head diameter affects early distal migration of a modular stem. However, the importance of correct stem sizing was revealed.

  5. An observational study comparing the prototype device with the existing device for the effective visualization of invisible veins in elderly patients in Japan.

    PubMed

    Kimori, Keiko; Sugama, Junko; Nakatani, Toshio; Nakayama, Kazuya; Miyati, Tosiaki; Sanada, Hiromi

    2015-01-01

    To compare the performance on the detection of the invisible veins between our modified prototype device and an existing device in elderly hospitalized patients. A prospective, cross-sectional, and observational study was performed in the invisible veins in elderly patients. The major variables, skin color near the invisible veins, and diameter and depth of the invisible veins were measured. The vein visualization rate was calculated as the ratio of the visualized veins to the invisible veins by the visualization device. We analyzed 53 invisible veins in the cubital fossa and 56 invisible veins in the forearm in a total of 72 patients (median age, 73 years). The visualization rate for our prototype device was higher than that for an existing device in the cubital fossa and the forearm sites. The visualized veins of the prototype device had a higher intensity ratio than that of an existing device. No significant differences were observed in the body mass index, vein depth, and vein diameter of the visualized veins at the cubital fossa and forearm sites. The prototype surpassed the existing device in visualizing the invisible veins. However, the prototype was unable to visualize all the invisible veins. We need to look for ways to reduce noise and to visualize the invisible veins, and the visualization rate of devices needs to be investigated in further association with the percentage of success with actual intravenous access and locating time to vein.

  6. CORROSION RESISTANT JACKETED METAL BODY

    DOEpatents

    Brugmann, E.W.

    1958-08-26

    Jacketed metal bodies of the type used as fuel elements for nuclear reactors, which contain an internal elongated body of fissionable material jacketed in a corrosion resistant metal are described. The ends of the internal bodies are provided with screw threads having a tapered outer end. The jacket material overlaps the ends and extends into the tapered section of the screw threaded opening. Screw caps with a mating tapered section are screwed into the ends of the body to compress the jacket material in the tapered sections to provtde an effective seal against corrosive gases and liquids.

  7. Coronary artery size and disease in UK South Asian and Caucasian men.

    PubMed

    Zindrou, Dlear; Taylor, Kenneth M; Bagger, Jens Peder

    2006-04-01

    South Asian patients in the UK have a higher mortality rate after coronary artery bypass grafting (CABG) than Caucasian patients. As coronary artery size has been shown to correlate to outcome from bypass grafting, it has been suggested that smaller coronary arteries in South Asians as compared to Caucasians could contribute to a poorer outcome in the Asian population. We aimed to measure coronary artery size and disease in matched South Asian and Caucasian men undergoing first time coronary artery bypass grafting. Coronary arteriograms from 53 matched first generation South Asian and Caucasian men were examined. The patients had no history of myocardial infarction, coronary revascularisation, familial dyslipidaemia, diabetes or renal disease. They were individually matched for age, height, weight, body mass index and body surface area. Thereafter, coronary artery diameters and significant (> or =50%) diameter stenoses were measured in a blinded fashion using quantitative coronary angiography (QCA). In South Asian men, diameters of the left main stem (LMS) and the proximal left anterior descending, the circumflex and the right coronary arteries were 4.6+/-0.9 mm, 3.5+/-0.8 mm, 3.4+/-0.8 mm and 3.5+/-0.8 mm, respectively. The corresponding arterial diameters among Caucasian men (4.5+/-0.9 mm, 3.5+/-0.7 mm, 3.5+/-0.8 mm and 3.8+/-0.8 mm) did not differ from those in South Asians. There was no difference in the number of significant coronary artery stenoses between the two groups and no difference in bypass and cross-clamp times or in adverse outcome (one from each group died after coronary artery bypass grafting). Proximal coronary artery size and number of significant coronary stenoses did not differ between matched pairs of South Asian and Caucasian men using strict inclusion/exclusion criteria.

  8. Determinants of elevated pulse pressure in middle-aged and older subjects with uncomplicated systolic hypertension: the role of proximal aortic diameter and the aortic pressure-flow relationship.

    PubMed

    Mitchell, Gary F; Lacourcière, Yves; Ouellet, Jean-Pascal; Izzo, Joseph L; Neutel, Joel; Kerwin, Linda J; Block, Alan J; Pfeffer, Marc A

    2003-09-30

    Elevated pulse pressure (PP) is associated with increased cardiovascular risk and is thought to be secondary to elastin fragmentation with secondary collagen deposition and stiffening of the aortic wall, leading to a dilated, noncompliant vasculature. By use of calibrated tonometry and pulsed Doppler, arterial stiffness and pulsatile hemodynamics were assessed in 128 subjects with uncomplicated systolic hypertension (supine systolic pressure > or =140 mm Hg off medication) and 30 normotensive control subjects of comparable age and gender. Pulse-wave velocity was assessed from tonometry and body surface measurements. Characteristic impedance (Zc) was calculated from the ratio of change in carotid pressure and aortic flow in early systole. Effective aortic diameter was assessed by use of the water hammer equation. Hypertensives were heavier (P<0.001) and had higher PP (P<0.001), which was attributable primarily to higher Zc (P<0.001), especially in women. Pulse-wave velocity was higher in hypertensives (P=0.001); however, this difference was not significant after adjustment for differences in mean arterial pressure (MAP) (P>0.153), whereas increased Zc remained highly significant (P<0.001). Increased Zc in women and in hypertensive men was attributable to decreased effective aortic diameter, with no difference in wall stiffness at comparable MAP and body weight. Elevated PP in systolic hypertension was independent of MAP and was attributable primarily to elevated Zc and reduced effective diameter of the proximal aorta. These findings are not consistent with the hypothesis of secondary aortic degeneration, dilation, and wall stiffening but rather suggest that aortic function may play an active role in the pathophysiology of systolic hypertension.

  9. Intraoperative Assessment of Esophagogastric Junction Distensibility During Laparoscopic Heller Myotomy.

    PubMed

    DeHaan, Reece K; Frelich, Matthew J; Gould, Jon C

    2016-04-01

    We sought to characterize the changes in esophagogastric junction (EGJ) distensibility during Heller Myotomy with Dor fundoplication using the EndoFLIP device. Intraoperative distensibility measurements on 14 patients undergoing Heller myotomy with Dor fundoplication were conducted over an 18-month period. Minimum esophageal diameter, cross-sectional areas, and distensibility index were measured at 30 and 40 mL catheter volumes before myotomy, postmyotomy, and following Dor fundoplication. Distensibility index is defined as the narrowest cross-sectional area divided by the corresponding pressure expressed in mm/mm Hg. Heller myotomy was found to lead to significant changes in the distensibility characteristics of the EGJ. Minimum esophageal diameter and EGJ distensibility increased significantly with Heller myotomy.

  10. Micro-scale pollution mechanism of dust diffusion in a blasting driving face based on CFD-DEM coupled model.

    PubMed

    Yu, Haiming; Cheng, Weimin; Xie, Yao; Peng, Huitian

    2018-05-23

    In order to investigate the diffuse pollution mechanisms of high-concentration dusts in the blasting driving face, the airflow-dust coupled model was constructed based on CFD-DEM coupled model; the diffusion rules of the dusts with different diameters at microscopic scale were analyzed in combination with the field measured results. The simulation results demonstrate that single-exhaust ventilation exhibited more favorable dust suppression performance than single-forced ventilation. Under single-exhaust ventilation condition, the motion trajectories of the dusts with the diameter smaller than 20 μm were close to the airflow streamline and these dusts were mainly distributed near the footway walls; by contrast, under single-forced ventilation condition, the motion trajectories of the dust particles with a diameter range of 20~40 μm were close to the airflow streamlines, and a large number of dusts with the diameter smaller than 20 μm accumulated in the regions 5 m and 17~25 m away from the head-on section. Moreover, under the single-exhaust ventilation, the relationship between dust diameter D and negative-pressured-induced dust emission ratio P can be expressed as P = - 25.03ln(D) + 110.39, and the dust emission ratio was up to 74.36% for 7-μm dusts, and the path-dependent settling behaviors of the dusts mainly occurred around the head-on section; under single-forced ventilation condition, the z value of the dusts with the diameter over 20 μm decreased and the dusts with a diameter smaller than 7 μm are particularly harmful to human health, but their settling ratios were below 22.36%. Graphical abstract The airflow-dust CFD-DEM coupling model was established. The numerical simulation results were verified. The migration laws of airflow field were obtained in a blasting driving face. The diffusion laws of dusts were obtained after blasting.

  11. Electromagnetically driven peristaltic pump

    DOEpatents

    Marshall, Douglas W.

    2000-01-01

    An electromagnetic peristaltic pump apparatus may comprise a main body section having an inlet end and an outlet end and a flexible membrane which divides the main body section into a first cavity and a second cavity. The first cavity is in fluid communication with the inlet and outlet ends of the main body section. The second cavity is not in fluid communication with the first cavity and contains an electrically conductive fluid. The second cavity includes a plurality of electrodes which are positioned within the second cavity generally adjacent the flexible membrane. A magnetic field generator produces a magnetic field having a plurality of flux lines at least some of which are contained within the second cavity of the main body section and which are oriented generally parallel to a flow direction in which a material flows between the inlet and outlet ends of the main body section. A control system selectively places a voltage potential across selected ones of the plurality of electrodes to deflect the flexible membrane in a wave-like manner to move material contained in the first cavity between the inlet and outlet ends of the main body section.

  12. Comparison of Fluoroscopy and Computed Tomography for Tracheal Lumen Diameter Measurement and Determination of Intraluminal Stent Size in Healthy Dogs

    PubMed Central

    Williams, Jackie M.; Krebs, Ingar A.; Riedesel, Elizabeth A.; Zhao, Qianqian

    2015-01-01

    Tracheal collapse is a progressive airway disease that can ultimately result in complete airway obstruction. Intraluminal tracheal stents are a minimally invasive and viable treatment for tracheal collapse once the disease becomes refractory to medical management. Intraluminal stent size is chosen based on the maximum measured tracheal diameter during maximum inflation. The purpose of this prospective, cross-sectional study was to compare tracheal lumen diameter measurements and subsequent selected stent size using both fluoroscopy and CT and to evaluate inter- and intraobserver variability of the measurements. Seventeen healthy Beagles were anesthetized and imaged with fluoroscopy and CT with positive pressure ventilation to 20 cm H2O. Fluoroscopic and CT maximum tracheal diameters were measured by 3 readers. Three individual measurements were made at 8 pre-determined tracheal sites for dorsoventral (height) and laterolateral (width) dimensions. Tracheal diameters and stent sizes (based on the maximum tracheal diameter + 10%) were analyzed using a linear mixed model. CT tracheal lumen diameters were larger compared to fluoroscopy at all locations. When comparing modalities, fluoroscopic and CT stent sizes were statistically different. Greater overall variation in tracheal diameter measurement (height or width) existed for fluoroscopy compared to CT, both within and among observers. The greater tracheal diameter and lower measurement variability supported the use of CT for appropriate stent selection to minimize complications in veterinary patients. PMID:26784924

  13. Quantification of eggshell microstructure using X-ray micro computed tomography

    PubMed Central

    Riley, A.; Sturrock, C. J.; Mooney, S. J.

    2014-01-01

    1. X-ray microcomputed tomography can be used to produce rapid, fully analysable, three-dimensional images of biological and other materials without the need for complex or tedious sample preparation and sectioning. We describe the use of this technique to visualise and analyse the microstructure of fragments of shell taken from three regions of chicken eggs (sharp pole, blunt pole and equatorial region). 2. Two- and three-dimensional images and data were obtained at a resolution of 1.5 microns. The images were analysed to provide measurements of shell thickness, the spacial density of mammillary bodies, the frequency, shape, volume and effective diameter of individual pore spaces, and the intrinsic sponginess (proportion of non-X-ray dense material formed by vesicles) of the shell matrix. Measurements of these parameters were comparable with those derived by traditional methods and reported in the literature. 3. The advantages of using this technology for the quantification of eggshell microstructural parameters and its potential application for commercial, research and other purposes are discussed. PMID:24875292

  14. Does Your Optical Particle Counter Measure What You Think it Does? Calibration and Refractive Index Correction Methods.

    NASA Astrophysics Data System (ADS)

    Rosenberg, Phil; Dean, Angela; Williams, Paul; Dorsey, James; Minikin, Andreas; Pickering, Martyn; Petzold, Andreas

    2013-04-01

    Optical Particle Counters (OPCs) are the de-facto standard for in-situ measurements of airborne aerosol size distributions and small cloud particles over a wide size range. This is particularly the case on airborne platforms where fast response is important. OPCs measure scattered light from individual particles and generally bin particles according to the measured peak amount of light scattered (the OPC's response). Most manufacturers provide a table along with their instrument which indicates the particle diameters which represent the edges of each bin. It is important to correct the particle size reported by OPCs for the refractive index of the particles being measured, which is often not the same as for those used during calibration. However, the OPC's response is not a monotonic function of particle diameter and obvious problems occur when refractive index corrections are attempted, but multiple diameters correspond to the same OPC response. Here we recommend that OPCs are calibrated in terms of particle scattering cross section as this is a monotonic (usually linear) function of an OPC's response. We present a method for converting a bin's boundaries in terms of scattering cross section into a bin centre and bin width in terms of diameter for any aerosol species for which the scattering properties are known. The relationship between diameter and scattering cross section can be arbitrarily complex and does not need to be monotonic; it can be based on Mie-Lorenz theory or any other scattering theory. Software has been provided on the Sourceforge open source repository for scientific users to implement such methods in their own measurement and calibration routines. As a case study data is presented showing data from Passive Cavity Aerosol Spectrometer Probe (PCASP) and a Cloud Droplet Probe (CDP) calibrated using polystyrene latex spheres and glass beads before being deployed as part of the Fennec project to measure airborne dust in the inaccessible regions of the Sahara.

  15. Body surface area as a key determinant of aortic root and arch dimensions in a population-based study.

    PubMed

    Wang, Yan-Li; Wang, Qing-Ling; Wang, Liang; Wu, Ying-Biao; Wang, Zhi-Bin; Cameron, James; Liang, Yu-Lu

    2013-02-01

    The associations between the aortic dimensions (of the aortic sinus, aortic annulus and aortic arch) and physiological variables have not been established in the Chinese population. The present study examined the associations among physiological variables to determine the aortic root and arch dimensions echocardiographically. The diameters of the aortic sinus, annulus and arch were measured in 1,010 subjects via 2-D echocardiography with a 3.5-MHz transducer in a trans-thoracic position. The images of the aortic sinus and aortic annulus were obtained from a standard parasternal long-axis view. The maximum diameter of the valve orifice was measured at the end of systole. The aortic arch dimension was visualized in the long-axis using a suprasternal notch window and the maximum transverse diameter was measured. Epidata 3.0, Excel 2007 and SPSS version 17.0 were used to collect and analyze the data. A total of 1,010 subjects were enrolled. The mean age was 55.0±17.0 years (range of 18 to 90 years). The body surface area (BSA) was the best predictor of all the studied physiological variables and may be used to predict aortic sinus, annulus and arch dimensions independently (r=0.54, 0.37 and 0.39, respectively). Gender, blood pressure, age and BSA are significant predictors of the aortic dimensions. Of these, BSA was the best predictor.

  16. Stress relaxation of grouted entirely large diameter B-GFRP soil nail

    NASA Astrophysics Data System (ADS)

    Li, Guo-wei; Ni, Chun; Pei, Hua-fu; Ge, Wan-ming; Ng, Charles Wang Wai

    2013-08-01

    One of the potential solutions to steel-corrosion-related problems is the usage of fiber reinforced polymer (FRP) as a replacement of steel bars. In the past few decades, researchers have conducted a large number of experimental and theoretical studies on the behavior of small size glass fiber reinforce polymer (GFRP) bars (diameter smaller than 20 mm). However, the behavior of large size GFRP bar is still not well understood. Particularly, few studies were conducted on the stress relaxation of grouted entirely large diameter GFRP soil nail. This paper investigates the effect of stress levels on the relaxation behavior of GFRP soil nail under sustained deformation ranging from 30% to 60% of its ultimate strain. In order to study the behavior of stress relaxation, two B-GFRP soil nail element specimens were developed and instrumented with fiber Bragg grating (FBG) strain sensors which were used to measure strains along the B-GFRP bars. The test results reveal that the behavior of stress relaxation of B-GFRP soil nail element subjected to pre-stress is significantly related to the elapsed time and the initial stress of relaxation procedure. The newly proposed model for evaluating stress relaxation ratio can substantially reflect the influences of the nature of B-GFRP bar and the property of grip body. The strain on the nail body can be redistributed automatically. Modulus reduction is not the single reason for the stress degradation.

  17. Development of tissue-engineered self-expandable aortic stent grafts (Bio stent grafts) using in-body tissue architecture technology in beagles.

    PubMed

    Kawajiri, Hidetake; Mizuno, Takeshi; Moriwaki, Takeshi; Ishibashi-Ueda, Hatsue; Yamanami, Masashi; Kanda, Keiichi; Yaku, Hitoshi; Nakayama, Yasuhide

    2015-02-01

    In this study, we aimed to describe the development of tissue-engineered self-expandable aortic stent grafts (Bio stent graft) using in-body tissue architecture technology in beagles and to determine its mechanical and histological properties. The preparation mold was assembled by insertion of an acryl rod (outer diameter, 8.6 mm; length, 40 mm) into a self-expanding nitinol stent (internal diameter, 9.0 mm; length, 35 mm). The molds (n = 6) were embedded into the subcutaneous pouches of three beagles for 4 weeks. After harvesting and removing each rod, the excessive fragile tissue connected around the molds was trimmed, and thus tubular autologous connective tissues with the stent were obtained for use as Bio stent grafts (outer diameter, approximately 9.3 mm in all molds). The stent strut was completely surrounded by the dense collagenous membrane (thickness, ∼150 µm). The Bio stent graft luminal surface was extremely flat and smooth. The graft wall of the Bio stent graft possessed an elastic modulus that was almost two times higher than that of the native beagle abdominal aorta. This Bio stent graft is expected to exhibit excellent biocompatibility after being implanted in the aorta, which may reduce the risk of type 1 endoleaks or migration. © 2014 Wiley Periodicals, Inc.

  18. Confined Impinging Jets in Porous Media

    NASA Astrophysics Data System (ADS)

    Buonomo, B.; Cirillo, L.; Manca, O.; Mansi, N.; Nardini, S.

    2016-09-01

    Impinging jets are adopted in drying of textiles, paper, cooling of gas turbine components, freezing of tissue in cryosurgery and manufacturing, electronic cooling. In this paper an experimental investigation is carried out on impinging jets in porous media with the wall heated from below with a uniform heat flux. The fluid is air. The experimental apparatus is made up of a fun systems, a test section, a tube, to reduce the section in a circular section. The tube is long 1.0 m and diameter of 0.012 m. The test section has a diameter of 0.10 m and it has the thickness of 10, 20 and 40 mm. In the test section the lower plate is in aluminum and is heated by an electrical resistance whereas the upper plate is in Plexiglas. The experiments are carried out employing a aluminum foam 40 PPI at three thickness as the test section. Results are obtained in a Reynolds number range from 5100 to 15300 and wall heat flux range from 510 W/m2 to 1400 W/m2. Results are given in terms of wall temperature profiles, local and average Nusselt numbers, pressure drops, friction factor and Richardson number.

  19. An atmosphere on Ganymede from its occultation of SAO 186800 on 7 June 1972.

    NASA Technical Reports Server (NTRS)

    Carlson, R. W.; Bhattacharyya, J. C.; Smith, B. A.; Johnson, T. V.; Hidayat, B.; Smith, S. A.; Taylor, G. E.; O'Leary, B.; Brinkmann, R. T.

    1973-01-01

    The observational data obtained during the occultation are of sufficient quality to determine the occultation radius and to support the inference that Ganymede does possess at least a modest atmosphere. Assuming a circular cross section, the diameter of Ganymede was found to be 5271 km. Effects of the atmosphere on the accuracy of the value obtained for the Ganymede diameter are discussed.

  20. Approximation of the breast height diameter distribution of two-cohort stands by mixture models III Kernel density estimators vs mixture models

    Treesearch

    Rafal Podlaski; Francis A. Roesch

    2014-01-01

    Two-component mixtures of either the Weibull distribution or the gamma distribution and the kernel density estimator were used for describing the diameter at breast height (dbh) empirical distributions of two-cohort stands. The data consisted of study plots from the Å wietokrzyski National Park (central Poland) and areas close to and including the North Carolina section...

  1. Distal Ureteral Diameter Ratio is Predictive of Breakthrough Febrile Urinary Tract Infection.

    PubMed

    Arlen, Angela M; Leong, Traci; Guidos, P Joseph; Alexander, Siobhan E; Cooper, Christopher S

    2017-12-01

    Distal ureteral diameter ratio is an objective measure that is prognostic of spontaneous resolution of vesicoureteral reflux. Along with likelihood of resolution, improved identification of children at risk for recurrent febrile urinary tract infections may impact management decisions. We evaluated the usefulness of ureteral diameter ratio as a predictive factor for breakthrough febrile urinary tract infections. Children with primary vesicoureteral reflux and detailed voiding cystourethrogram were identified. Ureteral diameter ratio was computed by measuring largest ureteral diameter within the pelvis and dividing by the distance between L1 and L3 vertebral bodies. Demographics, vesicoureteral reflux grade, laterality, presence/absence of bladder-bowel dysfunction, and ureteral diameter ratio were tested in univariate and multivariable analyses. Primary outcome was breakthrough febrile urinary tract infections. We analyzed 112 girls and 28 boys with a mean ± SD age of 2.5 ± 2.3 years at diagnosis. Vesicoureteral reflux was grade 1 to 2 in 64 patients (45.7%), grade 3 in 50 (35.7%), grade 4 in 16 (11.4%) and grade 5 in 10 (7.2%). Mean ± SD followup was 3.2 ± 2.7 years. A total of 40 children (28.6%) experienced breakthrough febrile urinary tract infections. Ureteral diameter ratio was significantly greater in children with (0.36) vs without (0.25) breakthrough febrile infections (p = 0.004). Controlling for vesicoureteral reflux grade, every 0.1 U increase in ureteral diameter ratio resulted in 1.7 times increased odds of breakthrough infection (95% CI 1.24 to 2.26, p <0.0001). Children with increased distal ureteral diameter ratio are at greater risk for breakthrough febrile urinary tract infections independent of reflux grade. Ureteral diameter ratio provides valuable prognostic information about risk of recurrent pyelonephritis and may assist with clinical decision-making. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  2. Turbulent axisymmetric swirling wake: equilibrium similarity solution and experiments with a wind turbine as wake generator

    NASA Astrophysics Data System (ADS)

    Wosnik, Martin; Dufresne, Nathaniel

    2013-11-01

    An analytical and experimental investigation of the turbulent axisymmetric swirling wake was carried out. An equilibrium similarity theory was derived that obtained scaling functions from conditions for similarity from the equations of motion, leading to a new scaling function for the decay of the swirling velocity component. Axial and azimuthal (swirl) velocity fields were measured in the wake of a single 3-bladed model wind turbine with rotor diameter of 0.91 m, up to 20 diameters downstream, using X-wire constant temperature hot-wire anemometry. The turbine was positioned in the free stream, near the entrance of the UNH Flow Physics Facility, which has a test section of 6m × 2.7m cross section and 72m length. Measurements were conducted at different rotor loading conditions with blade tip-speed ratios up to 2.8. At U∞ = 7 m/s, the Reynolds number based on turbine diameter was approximately 5 ×105 . Both mean velocity deficit and mean swirl were found to persist beyond 20 diameters downstream. First evidence for a new scaling function for the mean swirl, Wmax ~Uo3 / 2 ~x-1 was found. The similarity solution thus predicts that in the axisymmetric swirling wake mean swirl decays faster with x-1 than mean velocity deficit with x - 2 / 3.

  3. Vital exhaustion and anxiety are related to subjective quality of life in patients with acute myocardial infarct before cardiac rehabilitation.

    PubMed

    Rafael, Beatrix; Simon, Attila; Drótos, Gergely; Balog, Piroska

    2014-10-01

    To examine psychological risk factors and somatic factors in patients after myocardial infarction. To study the relationship between somatic and psychological factors, their influence on subjective quality of life (well-being) and also to examine possible gender differences. There has been a growing body of evidence that psychosocial factors are risk factors for incident and recurrent myocardial infarction. Descriptive correlational and cross-sectional survey design. In patients (n = 97, 67 men), the level of depression and anxiety, vital exhaustion, sleep disturbances and well-being were assessed. Left ventricular ejection fraction, left ventricular diastolic diameter, body mass index, metabolic equivalents and the number of diseased vessels were retrieved from medical records. Anxiety, vital exhaustion and sleep disturbances were significantly higher in women than in men. Well-being showed a significant linear correlation with body mass index, anxiety, depression, vital exhaustion and sleep disturbances scores. After adjustment for psychological risk factors and somatic parameters, only vital exhaustion and anxiety correlated significantly with well-being. However, there were gender differences in predictive variables of well-being. Anxiety in men and vital exhaustion in women showed a linear correlation with the subjective quality of life. Our study revealed that only vital exhaustion and anxiety showed a significant correlation with well-being in patients. During cardiac rehabilitation, it is important to detect and treat not only depression but also vital exhaustion and anxiety, because by reducing these psychological conditions, we can improve well-being. © 2014 John Wiley & Sons Ltd.

  4. Preliminary analysis of facial hair follicle distribution for forensic identification using OCT

    NASA Astrophysics Data System (ADS)

    Zhang, Ning; Wang, Chengming; Li, Zhigang; Xie, Lanchi; Guo, Jingjing; Xu, Lei; Yan, Yuwen; Li, Zhihui; Huang, Wei; Xu, Xiaojing

    2018-02-01

    In most deaths caused by explosions, the fragment of explosive remained on the victim's body can provide valuable clues to forensic investigation. However, the examination of the skin and appendages at the scene of explosion, which may reveal clue to the identity of an individual, has not been extensively studied. Compared with visual appearance of the epidermis surface that affected by various wounds, skin adnexa embedded in the dermis has a more stable morphology as an inner biometric. Hair follicles are formed when a fetus is 5 months old and distributed fairly evenly throughout the body, with the exception of hairless palms and soles. Therefore, we focus on the distribution of hair follicles in order to infer information of age, gender, and race/ethnicity. Optical coherence tomography (OCT) is a novel forensic imaging method, which achieves non-destructive, high-resolution and most importantly cross-sectional imaging. In this study, we design and develop a custom-built spectral-domain three-dimensional (3D) OCT system with a portable handheld probe to detect and reconstruct the hair follicles in the facial skin. We test our system on the forehead and preauricular skin of 2 adult volunteers and demonstrate the high quality visualization of hair follicles beneath the epidermis. The diameter, orientation, density and shape of hair follicles can be extracted from the 3D volume data. The preliminary analysis suggests that these parameters vary from different part of body and have individual difference. Eventually, we believe 3D OCT is promising tool for the examination of hair follicles for forensic purpose.

  5. [Is our approach to thyroid nodules and differentiated thyroid carcinoma in agreement with the American guideline and European consensus?].

    PubMed

    Gómez Sáez, José Manuel

    2010-10-01

    The aim of this study was to assess the approaches of specialists in Spain to patients with thyroid nodules and differentiated thyroid carcinoma and to compare them with the American guideline and European consensus. We performed a cross-sectional study based on a questionnaire addressed to clinical endocrinologists specialized in thyroid cancer and specialists in nuclear medicine throughout Spain. A total of 177 questionnaires were completed, representing an overall response rate of 85%; 74% of responses were from endocrinologists and 24% from physicians active in nuclear medicine; 82% of respondents worked in third-level hospitals, 10% in second level hospitals and the remainder in private practice. Most used ultrasonography and cytology to assess thyroid nodules and collaborated with a group of surgeons expert in thyroid surgery. The majority preferred total or subtotal thyroidectomy in tumors with a diameter of 1 cm or more, and systematic lymph node dissection. Only 43 (24%) preferred prophylactic central lymph node dissection. Eighty-one respondents (45%) would still use whole body scan with ¹³¹I or ¹²³I before ¹³¹I ablation. Follow-up was based on cervical echography and thyroglobulin determination; however, 101 (57%) respondents continued to use diagnostic whole body scan in the follow-up. The approaches of the respondents were mainly in accordance with the guideline and consensus, although some variations were found, especially in the use of whole body scan with ¹³¹I before ablation and in follow-up. Copyright © 2010 SEEN. Published by Elsevier Espana. All rights reserved.

  6. Comparison of radiography and ultrasonography for diagnosing small-intestinal mechanical obstruction in vomiting dogs.

    PubMed

    Sharma, Ajay; Thompson, Margret S; Scrivani, Peter V; Dykes, Nathan L; Yeager, Amy E; Freer, Sean R; Erb, Hollis N

    2011-01-01

    A cross-sectional study was performed on acutely vomiting dogs to compare the accuracy of radiography and ultrasonography for the diagnosis of small-intestinal mechanical obstruction and to describe several radiographic and ultrasonographic signs to identify their contribution to the final diagnosis. The sample population consisted of 82 adult dogs and small-intestinal obstruction by foreign body was confirmed in 27/82 (33%) dogs by surgery or necropsy. Radiography produced a definitive result (obstructed or not obstructed) in 58/82 (70%) of dogs; ultrasonography produced a definitive result in 80/82 (97%) of dogs. On radiographs, a diagnosis of obstruction was based on detection of segmental small-intestinal dilatation, plication, or detection of a foreign body. Approximately 30% (8/27) of obstructed dogs did not have radiographic signs of segmental small-intestinal dilatation, of which 50% (4/8) were due to linear foreign bodies. The ultrasonographic diagnosis of small-intestinal obstruction was based on detection of an obstructive lesion, sonographic signs of plication or segmental, small-intestinal dilatation. The ultrasonographic presence or absence of moderate-to-severe intestinal diameter enlargement (due to lumen dilatation) of the jejunum (>1.5 cm) was a useful discriminatory finding and, when present, should prompt a thorough search for a cause of small-intestinal obstruction. In conclusion, both abdominal radiography and abdominal ultrasonography are accurate for diagnosing small-intestinal obstruction in vomiting dogs and either may be used depending on availability and examiner choice. Abdominal ultrasonography had greater accuracy, fewer equivocal results and provided greater diagnostic confidence compared with radiography. © 2010 Veterinary Radiology & Ultrasound.

  7. Alining Large Cylinders for Welding

    NASA Technical Reports Server (NTRS)

    Ehl, J. H.

    1985-01-01

    Special tooling alines and holds internally-stiffened large-diameter cylindrical parts for welding. Alinement brackets attached to strengthening fins on insides of cylindrical tank sections. Jackscrews on brackets raised or lowered to eliminate mismatches between adjacent sections. Tooling substantially reduces costs while allowing more precise control and improved quality.

  8. Space vehicle with artificial gravity and earth-like environment

    NASA Technical Reports Server (NTRS)

    Gray, V. H. (Inventor)

    1973-01-01

    A space vehicle adapted to provide an artificial gravity and earthlike atmospheric environment for occupants is disclosed. The vehicle comprises a cylindrically shaped, hollow pressure-tight body, one end of which is tapered from the largest diameter of the body, the other end is flat and transparent to sunlight. The vehicle is provided with thrust means which rotates the body about its longitudinal axis, generating an artificial gravity effect upon the interior walls of the body due to centrifugal forces. The walls of the tapered end of the body are maintained at a temperature below the dew point of water vapor in the body and lower than the temperature near the transparent end of the body. The controlled environment and sunlight permits an earth like environment to be maintained wherein the CO2/O2 is balanced, and food for the travelers is supplied through a natural system of plant life grown on spacecraft walls where soil is located.

  9. Towards revealing the structure of bacterial inclusion bodies

    PubMed Central

    2009-01-01

    Protein aggregation is a widely observed phenomenon in human diseases, biopharmaceutical production, and biological research. Protein aggregates are generally classified as highly ordered, such as amyloid fibrils, or amorphous, such as bacterial inclusion bodies. Amyloid fibrils are elongated filaments with diameters of 6–12 nm, they are comprised of residue-specific cross-β structure, and display characteristic properties, such as binding with amyloid-specific dyes. Amyloid fibrils are associated with dozens of human pathological conditions, including Alzheimer disease and prion diseases. Distinguished from amyloid fibrils, bacterial inclusion bodies display apparent amorphous morphology. Inclusion bodies are formed during high-level recombinant protein production, and formation of inclusion bodies is a major concern in biotechnology. Despite of the distinctive morphological difference, bacterial inclusion bodies have been found to have some amyloid-like properties, suggesting that they might contain structures similar to amyloid-like fibrils. Recent structural data further support this hypothesis, and this review summarizes the latest progress towards revealing the structural details of bacterial inclusion bodies. PMID:19806034

  10. Towards revealing the structure of bacterial inclusion bodies.

    PubMed

    Wang, Lei

    2009-01-01

    Protein aggregation is a widely observed phenomenon in human diseases, biopharmaceutical production, and biological research. Protein aggregates are generally classified as highly ordered, such as amyloid fibrils, or amorphous, such as bacterial inclusion bodies. Amyloid fibrils are elongated filaments with diameters of 6-12 nm, they are comprised of residue-specific cross-beta structure, and display characteristic properties, such as binding with amyloid-specific dyes. Amyloid fibrils are associated with dozens of human pathological conditions, including Alzheimer disease and prion diseases. Distinguished from amyloid fibrils, bacterial inclusion bodies display apparent amorphous morphology. Inclusion bodies are formed during high-level recombinant protein production, and formation of inclusion bodies is a major concern in biotechnology. Despite of the distinctive morphological difference, bacterial inclusion bodies have been found to have some amyloid-like properties, suggesting that they might contain structures similar to amyloid-like fibrils. Recent structural data further support this hypothesis, and this review summarizes the latest progress towards revealing the structural details of bacterial inclusion bodies.

  11. Iridovirus disease in two ornamental tropical freshwater fishes: African lampeye and dwarf gourami.

    PubMed

    Sudthongkong, Chaiwud; Miyata, Masato; Miyazaki, Teruo

    2002-04-05

    Many species of ornamental freshwater fishes are imported into Japan from all over the world. We found African lampeye Aplocheilichthys normani and dwarf gourami Colisa lalia suffering from an iridovirus infection just after being imported by tropical fish wholesalers from Singapore. African lampeye were cultured on the Indonesian Island of Sumatra and dwarf gourami were cultured in Malaysia before export. Diseased fishes displayed distinct histopathological signs of iridovirus infection: systemic appearance of inclusion body-bearing cells, and necrosis of splenocytes and hematopoietic cells. Electron microscopy revealed viral particles (African lampeye:180 to 200 nm in edge to edge diameter; dwarf gourami: 140 to 150 nm in diameter) in an inclusion body within the cytoplasm of inclusion body-bearing cells as well as in the cytoplasm of necrotized cells. Experimental infection with an iridovirus isolate from African lampeye (ALIV) revealed pathogenicity of ALIV to African lampeye and pearl gourami Trichogaster leeri. Polymerase chain reaction (PCR) products from ALIV and an iridovirus isolate from dwarf gourami (DGIV) using iridovirus-specific primers were indistinguishable. The nucleotide sequence of PCR products derived from ALIV (696 base pairs) and DGIV (701 base pairs) had 95.3% identity. These results indicate that ALIV and DGIV have a single origin.

  12. Body and blubber relationships in antarctic pack ice seals: implications for blubber depth patterns.

    PubMed

    Castellini, M A; Trumble, S J; Mau, T L; Yochem, P K; Stewart, B S; Koski, M A

    2009-01-01

    Morphometrics and blubber depths from all four high Antarctic seals (Weddell, Ross, crabeater, and leopard) were obtained during a midsummer research cruise in the Ross Sea as the physiological ecology component of the U.S. Antarctic Pack Ice Seals project. These data are the only in vivo measurements of all four species from the same location and time of year and focused on variances in morphometrics and blubber depth related to species, sex, and age. By controlling for location and season, this cross-species design provided the means to differentiate how blubber mass might be influenced in these groups. We measured both absolute blubber depth and ratio of blubber depth to body core diameter. We found that adult and younger animals showed differences in blubber depth, but male versus female seals did not show differences within any given species. However, when compared across species, the ratio of blubber ring depth to body core diameter suggests that adult Weddell seals differ in their use of blubber compared with the other three species. We propose that this difference in blubber pattern is most likely related to Weddell nutritional requirements during the breeding season having a greater influence on blubber depth than thermal requirements when compared with the other three species.

  13. Power mixture and green body for producing silicon nitride base articles of high fracture toughness and strength

    DOEpatents

    Huckabee, M.L.; Buljan, S.T.; Neil, J.T.

    1991-09-17

    A powder mixture and a green body for producing a silicon nitride-based article of improved fracture toughness and strength are disclosed. The powder mixture includes (a) a bimodal silicon nitride powder blend consisting essentially of about 10-30% by weight of a first silicon nitride powder of an average particle size of about 0.2 [mu]m and a surface area of about 8-12m[sup 2]g, and about 70-90% by weight of a second silicon nitride powder of an average particle size of about 0.4-0.6 [mu]m and a surface area of about 2-4 m[sup 2]/g, (b) about 10-50 percent by volume, based on the volume of the densified article, of refractory whiskers or fibers having an aspect ratio of about 3-150 and having an equivalent diameter selected to produce in the densified article an equivalent diameter ratio of the whiskers or fibers to grains of silicon nitride of greater than 1.0, and (c) an effective amount of a suitable oxide densification aid. The green body is formed from the powder mixture, an effective amount of a suitable oxide densification aid, and an effective amount of a suitable organic binder. No Drawings

  14. Power mixture and green body for producing silicon nitride base & articles of high fracture toughness and strength

    DOEpatents

    Huckabee, Marvin L.; Buljan, Sergej-Tomislav; Neil, Jeffrey T.

    1991-01-01

    A powder mixture and a green body for producing a silicon nitride-based article of improved fracture toughness and strength. The powder mixture includes 9a) a bimodal silicon nitride powder blend consisting essentially of about 10-30% by weight of a first silicon mitride powder of an average particle size of about 0.2 .mu.m and a surface area of about 8-12m.sup.2 g, and about 70-90% by weight of a second silicon nitride powder of an average particle size of about 0.4-0.6 .mu.m and a surface area of about 2-4 m.sup.2 /g, (b) about 10-50 percent by volume, based on the volume of the densified article, of refractory whiskers or fibers having an aspect ratio of about 3-150 and having an equivalent diameter selected to produce in the densified articel an equivalent diameter ratio of the whiskers or fibers to grains of silicon nitride of greater than 1.0, and (c) an effective amount of a suitable oxide densification aid. The green body is formed from the powder mixture, an effective amount of a suitable oxide densification aid, and an effective amount of a suitable organic binder.

  15. Modeling Nanoparticle Wrapping or Translocation in Bilayer Membranes

    PubMed Central

    Curtis, Emily M.; Bahrami, Amir H.; Weikl, Thomas R.; Hall, Carol K.

    2015-01-01

    The spontaneous wrapping of nanoparticles by membranes is of increasing interest as nanoparticles become more prevalent in consumer products and hence more likely to enter the human body. We introduce a simulations-based tool that can be used to visualize the molecular level interaction between nanoparticles and bilayer membranes. By combining LIME, an intermediate resolution, implicit solvent model for phospholipids, with discontinuous molecular dynamics (DMD), we are able to simulate the wrapping or embedding of nanoparticles by 1,2-dipalmitoyl-sn-glycero-3-phosphocholine (DPPC) bilayer membranes. Simulations of hydrophilic nanoparticles with diameters from 10Å to 250Å show that hydrophilic nanoparticles with diameters greater than 20Å become wrapped while the nanoparticle with a diameter of 10Å does not . Instead this smaller particle became embedded in the bilayer surface where it could interact with the hydrophilic head groups of the lipid molecules. We also investigate the interaction between a DPPC bilayer and hydrophobic nanoparticles with diameters 10Å to 40Å. These nanoparticles do not undergo the wrapping process; instead they directly penetrate the membrane and embed themselves within the inner hydrophobic core of the bilayers. PMID:26260123

  16. Many Body Effects on Particle Diffusion in Polymer Nanocomposites

    NASA Astrophysics Data System (ADS)

    Dell, Zachary E.; Schweizer, Kenneth S.

    2014-03-01

    Recent statistical mechanical theories of nanoparticle motion in polymer melts and networks have focused on the dilute particle limit. By combining PRISM theory predictions for microscopic structural correlations, and a new formulation of self-consistent dynamical mode coupling theory, we extend dilute theories to finite filler loading. As a minimalist model, the polymer dynamics are first assumed to be unperturbed by the presence of the nanoparticles. The long time particle diffusivity in unentangled and entangled melts is determined as a function of polymer tube diameter and radius of gyration, nanoparticle diameter, and polymer-filler attraction strength under both constant volume and constant pressure situations. The influence of nanocomposite statistical structure (depletion, steric stabilization, bridging) on dynamics is also investigated. Using recent theoretical developments for predicting tube diameters in nanocomposites, the consequences of filler-induced tube dilation on nanoparticle motion is established. In entangled melts, increasing filler loading first modestly speeds up diffusion, and then dramatically when the inter-filler separation becomes smaller than the tube diameter. At very high loadings, a filler glass transition is generically predicted.

  17. Lunar Cratering Chronology: Calibrating Degree of Freshness of Craters to Absolute Ages

    NASA Astrophysics Data System (ADS)

    Trang, D.; Gillis-Davis, J.; Boyce, J. M.

    2013-12-01

    The use of impact craters to age-date surfaces of and/or geomorphological features on planetary bodies is a decades old practice. Various dating techniques use different aspects of impact craters in order to determine ages. One approach is based on the degree of freshness of primary-impact craters. This method examines the degradation state of craters through visual inspection of seven criteria: polygonality, crater ray, continuous ejecta, rim crest sharpness, satellite craters, radial channels, and terraces. These criteria are used to rank craters in order of age from 0.0 (oldest) to 7.0 (youngest). However, the relative decimal scale used in this technique has not been tied to a classification of absolute ages. In this work, we calibrate the degree of freshness to absolute ages through crater counting. We link the degree of freshness to absolute ages through crater counting of fifteen craters with diameters ranging from 5-22 km and degree of freshness from 6.3 to 2.5. We use the Terrain Camera data set on Kaguya to count craters on the continuous ejecta of each crater in our sample suite. Specifically, we divide the crater's ejecta blanket into quarters and count craters between the rim of the main crater out to one crater radii from the rim for two of the four sections. From these crater counts, we are able to estimate the absolute model age of each main crater using the Craterstats2 tool in ArcGIS. Next, we compare the degree of freshness for the crater count-derived age of our main craters to obtain a linear inverse relation that links these two metrics. So far, for craters with degree of freshness from 6.3 to 5.0, the linear regression has an R2 value of 0.7, which corresponds to a relative uncertainty of ×230 million years. At this point, this tool that links degree of freshness to absolute ages cannot be used with craters <8km because this class of crater degrades quicker than larger craters. A graphical solution exists for correcting the degree of freshness for craters <8 km in diameter. We convert this graphical solution to a single function of two independent variables, observed degree of freshness and crater diameter. This function, which results in a corrected degree of freshness is found through a curve-fitting routine and corrects the degree of freshness for craters <8 km in diameter. As a result, we are able to derive absolute ages from the degree of freshness of craters with diameters from about ≤20 km down to a 1 km in diameter with a precision of ×230 million years.

  18. 4 Metre diameter penstock construction for the Raymond Reservoir Hydro Project

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, H.D.; Alexander, M.

    1995-12-31

    A four metre diameter 770 m long buried steel penstock was constructed for the 20 MW Raymond Reservoir Hydro Project in southern Alberta. The penstock delivers up to 56.7 m{sup 3}/sec of irrigation water at an effective head of 44 m to a 2.6 m diameter Kaplan turbine. The hydro facility was commissioned in the spring of 1994. The steel pipe was delivered to the site in 18 m long sections from a fabrication plant located 250 km away. Specialized equipment was engineered and constructed to externally coat and internally line the pipe sections on site. The pipe sections, weighingmore » from 27,000 to 30,000 kg, were rolled and moved on a specially built lathe during the external sandblasting and tape wrapping operation. The external tape wrapping is one element of the cathodic protection system for the steel pipe. Specialized equipment was modified to sandblast the interior to white metal and then mechanically apply three coats of internal epoxy lining. The internal lining improves the hydraulic characteristics of the pipe in addition to protecting the pipe from corrosion. This innovative approach to coating and lining the pipe resulted in an exceptionally high quality product at an affordable cost.« less

  19. Refrigeration system oil measurement and sampling device

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Baker, J.A.

    1989-09-19

    This patent describes a sampling device for use with a refrigeration system having a refrigerant and oil entrained therein. It comprises: an elongated reservoir having a stepped bore therein for receiving refrigerant and oil carried thereby. The reservoir comprising a large bore diameter upper section having an index marking the fill level of the reservoir and a small bore diameter lower section having graduation marks for oil level measurement. The upper and lower sections comprising transparent material to allow observation of the contents, first valve means for coupling the reservoir to the refrigeration system to admit liquid refrigerant to themore » reservoir, second valve means for selectively coupling the reservoir to the low pressure side of the refrigeration system or to a vacuum line to evacuate vaporized refrigerant from the reservoir, and means for supplying heat to the refrigerant in the bore to facilitate vaporization of the refrigerant.« less

  20. Crushing characteristics of composite tubes with 'near-elliptical' cross sections

    NASA Astrophysics Data System (ADS)

    Farley, Gary L.; Jones, Robert M.

    1992-01-01

    An experimental investigation was conducted to determine whether the energy-absorption capability of near-elliptical cross-section composite tubular specimens is a function of included angle. Each half of the near-elliptical cross-section tube is a segment of a circle. The included angle is the angle created by radial lines extending from the center of the circular segment to the ends of the circular segment. Graphite- and Kevlar-reinforced epoxy material was used to fabricate specimens. Tube internal diameters were 2.54, 3.81, and 7.62 cm, and included angles were 180, 160, 135, and 90 degrees. Based upon the test results from these tubes, energy-absorption capability increased between 10 and 30 percent as included angle decreased between 180 and 90 degrees for the materials evaluated. Energy-absorption capability was a decreasing nonlinear function of the ratio of tube internal diameter to wall thickness.

  1. Mid-section of a can-annular gas turbine engine with a cooling system for the transition

    DOEpatents

    Wiebe, David J.; Rodriguez, Jose L.

    2015-12-08

    A cooling system is provided for a transition (420) of a gas turbine engine (410). The cooling system includes a cowling (460) configured to receive an air flow (111) from an outlet of a compressor section of the gas turbine engine (410). The cowling (460) is positioned adjacent to a region of the transition (420) to cool the transition region upon circulation of the air flow within the cowling (460). The cooling system further includes a manifold (121) to directly couple the air flow (111) from the compressor section outlet to an inlet (462) of the cowling (460). The cowling (460) is configured to circulate the air flow (111) within an interior space (426) of the cowling (460) that extends radially outward from an inner diameter (423) of the cowling to an outer diameter (424) of the cowling at an outer surface.

  2. Casing for a gas turbine engine

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wiebe, David J.; Little, David A.; Charron, Richard C.

    2016-07-12

    A casing for a can annular gas turbine engine, including: a compressed air section (40) spanning between a last row of compressor blades (26) and a first row of turbine blades (28), the compressed air section (40) having a plurality of openings (50) there through, wherein a single combustor/advanced duct assembly (64) extends through each opening (50); and one top hat (68) associated with each opening (50) configured to enclose the associated combustor/advanced duct assembly (64) and seal the opening (50). A volume enclosed by the compressed air section (40) is not greater than a volume of a frustum (54)more » defined at an upstream end (56) by an inner diameter of the casing at the last row of compressor blades (26) and at a downstream end (60) by an inner diameter of the casing at the first row of turbine blades (28).« less

  3. Does the type of renal artery anatomic variant determine the diameter of the main vessel supplying a kidney? A study based on CT data with a particular focus on the presence of multiple renal arteries.

    PubMed

    Majos, Marcin; Stefańczyk, Ludomir; Szemraj-Rogucka, Zofia; Elgalal, Marcin; De Caro, Raffaele; Macchi, Veronica; Polguj, Michał

    2018-04-01

    An in-depth knowledge of renal vascular anatomy is essential when planning many surgical procedures; however, a few data exists regarding renal artery diameter. The aim of this study was to assess this morphological feature and to investigate whether a correlation exists between renal artery diameter and the type of arterial supply, with a particular emphasis on variant anatomy and the presence of multiple renal arteries. Computed tomography angiography (CTA) studies of 248 patients, i.e., a total of 496 kidneys, were evaluated. The mean age of the patients was 66.4 ± 15.01 years. Renal artery diameter was measured based on the type of arterial blood supply. The frequency of occurrence of three anatomic variants of renal arterial supply was established: single renal artery (RA) 43.35%, single artery with prehilar branching (pRA) 37.30%, and multiple renal artery (mRA) 19.35%. The diameter of single renal arteries, with either prehilar or hilar branching, was significantly larger than when multiple arteries were present. A detailed analysis of just the mRA variant demonstrated that the diameter of the renal arteries in men was larger (p = 0.012) than those in women and that there was no difference in diameter with regard to the side of the body (p = 0.219). The classification described in our study containing a detailed description of renal artery diameter. It may be helpful in clinical practice, especially for transplantologists, surgeons, and vascular surgeons.

  4. Risk factors associated with delayed gastric emptying after subtotal gastrectomy with Billroth-I anastomosis using circular stapler for early gastric cancer patients.

    PubMed

    Kim, Ki Han; Kim, Min Chan; Jung, Ghap Joong

    2012-11-01

    Gastric surgery may potentiate delayed gastric emptying. Billroth I gastroduodenostomy using a circular stapler is the most preferable reconstruction method. The purpose of this study is to analyze the risk factors associated with delayed gastric emptying after radical subtotal gastrectomy with Billroth I anastomosis using a stapler for early gastric cancer. Three hundred and seventy-eight patients who underwent circular stapled Billroth I gastroduodenostomy after subtotal gastrectomy due to early gastric cancer were analyzed retrospectively. One hundred and eighty-two patients had Billroth I anastomosis using a 25 mm diameter circular stapler, and 196 patients had anastomosis with a 28 or 29 mm diameter circular stapler. Clinicopathological features and postoperative outcomes were evaluated and compared between the two groups. Delayed gastric emptying was diagnosed by symptoms and simple abdomen X-ray with or without upper gastrointestinal series or endoscopy. Postoperative delayed gastric emptying was found in 12 (3.2%) of the 378 patients. Among all the variables, distal margin and circular stapler diameter were significantly different between the cases with delayed gastric emptying and no delayed gastric emptying. There were statistically significant differences in sex, body mass index, comorbidity, complication, and operation type according to circular stapler diameter. In both univariate and multivariate logistic regression analyses, only the stapler diameter was found to be a significant factor affecting delayed gastric emptying (P = 0.040). In this study, the circular stapler diameter was one of the most significant predictable factors of delayed gastric emptying for Billroth I gastroduodenostomy. The use of a 28 or 29 mm diameter circular stapler rather than a 25 mm diameter stapler in stapled gastroduodenostomy for early gastric cancer can reduce postoperative delayed gastric emptying associated with anastomosic stenosis or edema with relative safety.

  5. Morphometry of impact craters on Mercury from MESSENGER altimetry and imaging

    NASA Astrophysics Data System (ADS)

    Susorney, Hannah C. M.; Barnouin, Olivier S.; Ernst, Carolyn M.; Johnson, Catherine L.

    2016-06-01

    Data acquired by the Mercury Laser Altimeter and the Mercury Dual Imaging System on the MESSENGER spacecraft in orbit about Mercury provide a means to measure the geometry of many of the impact craters in Mercury's northern hemisphere in detail for the first time. The combination of topographic and imaging data permit a systematic evaluation of impact crater morphometry on Mercury, a new calculation of the diameter Dt at which craters transition with increasing diameter from simple to complex forms, and an exploration of the role of target properties and impact velocity on final crater size and shape. Measurements of impact crater depth on Mercury confirm results from previous studies, with the exception that the depths of large complex craters are typically shallower at a given diameter than reported from Mariner 10 data. Secondary craters on Mercury are generally shallower than primary craters of the same diameter. No significant differences are observed between the depths of craters within heavily cratered terrain and those of craters within smooth plains. The morphological attributes of craters that reflect the transition from simple to complex craters do not appear at the same diameter; instead flat floors first appear with increasing diameter in craters at the smallest diameters, followed with increasing diameter by reduced crater depth and rim height, and then collapse and terracing of crater walls. Differences reported by others in Dt between Mercury and Mars (despite the similar surface gravitational acceleration on the two bodies) are confirmed in this study. The variations in Dt between Mercury and Mars cannot be adequately attributed to differences in either surface properties or mean projectile velocity.

  6. Experimental aerodynamics characteristics for bodies of elliptic cross section at angles of attack from 0 deg to 58 deg and Mach numbers from 0.6 to 2.0

    NASA Technical Reports Server (NTRS)

    Jorgensen, L. H.; Nelson, E. R.

    1975-01-01

    An experimental investigation was conducted to measure the static aerodynamic characteristics for two bodies of elliptic cross section and for their equivalent body of revolution. The equivalent body of revolution had the same length and axial distribution of cross-sectional area as the elliptic bodies. It consisted of a tangent ogive nose of fineness ratio 3 followed by a cylinder with a fineness ratio of 7. All bodies were tested at Mach numbers of 0.6, 0.9, 1.2, 1.5, and 2.0 at angles of attack from 0 deg to 58 deg. The data demonstrate that the aerodynamic characteristics can be significantly altered by changing the body cross section from circular to elliptic and by rolling the body from 0 deg to 90 deg. For example, the first elliptic body (with a constant cross-sectional axis ratio of 2) developed at zero roll about twice the normal force developed by the equivalent body of revolution. At some angles of attack greater than about 25 deg, side forces and yawing moments were measured in spite of the fact that the bodies were tested at zero angle of sideslip. The side-force and yawing-moment coefficients decreased with an increase in Mach number and essentially disappeared for all the bodies at Mach numbers greater than 1.2. From the standpoint of reducing undesirable side forces at high angles of attack, it is best to have the flattest side of the nose of the elliptic bodies pitching against the stream crossflow. The effect of Reynolds number was also the least significant for both elliptic bodies when the flattest side of the nose was pitched against the stream crossflow.

  7. The effect of screw tunnels on the biomechanical stability of vertebral body after pedicle screws removal: a finite element analysis.

    PubMed

    Liu, Jia-Ming; Zhang, Yu; Zhou, Yang; Chen, Xuan-Yin; Huang, Shan-Hu; Hua, Zi-Kai; Liu, Zhi-Li

    2017-06-01

    Posterior reduction and pedicle screw fixation is a widely used procedure for thoracic and lumbar vertebrae fractures. Usually, the pedicle screws would be removed after the fracture healing and screw tunnels would be left. The aim of this study is to evaluate the effect of screw tunnels on the biomechanical stability of the lumbar vertebral body after pedicle screws removal by finite element analysis (FEA). First, the CT values of the screw tunnels wall in the fractured vertebral bodies were measured in patients whose pedicle screws were removed, and they were then compared with the values of vertebral cortical bone. Second, an adult patient was included and the CT images of the lumbar spine were harvested. Three dimensional finite element models of the L1 vertebra with unilateral or bilateral screw tunnels were created based on the CT images. Different compressive loads were vertically acted on the models. The maximum loads which the models sustained and the distribution of the force in the different parts of the models were recorded and compared with each other. The CT values of the tunnels wall and vertebral cortical bone were 387.126±62.342 and 399.204±53.612, which were not statistically different (P=0.149). The models of three dimensional tetrahedral mesh finite element of normal lumbar 1 vertebra were established with good geometric similarity and realistic appearance. After given the compressive loads, the cortical bone was the first one to reach its ultimate stress. The maximum loads which the bilateral screw tunnels model, unilateral screw tunnel model, and normal vertebral model can sustain were 3.97 Mpa, 3.83 Mpa, and 3.78 Mpa, respectively. For the diameter of the screw tunnels, the model with a diameter of 6.5 mm could sustain the largest load. In addition, the stress distributing on the outside of the cortical bone gradually decreased as the thickness of the tunnel wall increased. Based on the FEA, pedicle screw tunnels would not decrease the biomechanical stability and strength of the vertebral body. A large diameter of screw tunnel and thick tunnel wall were helpful for the biomechanical stability of the vertebral body.

  8. Altitude-Wind-Tunnel Investigation of Performance of Several Propellers on YP-47M Airplane at High Blade Loadings. 6; Hamilton Standard 6507A-2 Four- and Three-Blade Propellers

    NASA Technical Reports Server (NTRS)

    Saari, Martin J.; Sorin, Solomon M.

    1946-01-01

    An altitude-wind-tunnel investigation has been made to determine the performance of Hamilton Standard 6507A-2 four-blade and three-blade propellers on a YP-47M airplane at high blade loadings and high engine powers. Characteristics of the four-blase propeller were obtained for a range of power coefficients from 0.10 to 1.00 at free-stream Mach numbers of 0.20, 0.30, 0.40. Characteristics of the three-blade propeller were obtained for a range of power coefficients from 0.30 to 1.00 at a free-stream Mach number of 0.40. Results of the force measurements indicate primarily the trend of propeller efficiency for changes in power coefficient or advance-diameter ratio because no corrections for the effects of tunnel-wall constriction on the installation were applied. Slipstream surveys are presented to illustrate blade thrust load distribution for certain operating conditions. Within the range of advance-diameter ratios investigated at each free-stream Mach number, the efficiency of the four-blade propeller decreased as the power coefficient was increased from 0.10 to 1.00. For the three-blade propeller, nearly constant maximum efficiencies were obtained for power coefficients from 0.32 to 0.63 at advance-diameter ratios between 1.90 and 3.00. In general, for conditions below the stall and critical tip Mach number, the maximum thrust load shifted from the inboard sections toward the tip sections as the power coefficient was increased or as the advance-diameter ratio was decreased. For conditions beyond the stall or critical tip Mach number, losses in thrust occurred on the outboard blade sections owing to flow break-down; the thrust load increased slightly on the inboard sections.

  9. The Effect of Reduction Gearing on Propeller-body Interference as Shown by Full-Scale Wind-Tunnel Tests

    NASA Technical Reports Server (NTRS)

    Weick, Fred E

    1931-01-01

    This report presents the results of full-scale tests made on a 10-foot 5-inch propeller on a geared J-5 engine and also on a similar 8-foot 11-inch propeller on a direct-drive J-5 engine. Each propeller was tested at two different pitch settings, and with a large and a small fuselage. The investigation was made in such a manner that the propeller-body interference factors were isolated, and it was found that, considering this interference only, the geared propellers had an appreciable advantage in propulsive efficiency, partially due to the larger diameter of the propellers with respect to the bodies, and partially because the geared propellers were located farther ahead of the engines and bodies.

  10. Aerodynamic Accounting Technique for Determining Effects of Nuclear Damage to Aircraft. Volume 2. Program User Guide

    DTIC Science & Technology

    1978-02-28

    of type I). 2.6 (1,5) Interference factor 2.7 (1,6) Number of bodies of type I 2.8 (1,7)* Maximum cross -sectional area 2.9 (1,8...height, cross -sectional area, etc. listed for each body type describes a single body. The total number of bodies of each type must also be specified even...71+1) (1,6) Number of bodies of Type I (78+1) (1,7)** Maximum cross -sectional area (85+1) (1,8) Base atreamtube area (92+1) (119) Nose length

  11. Law No. 711 on fertilization outside the human body, 14 June 1988.

    PubMed

    1988-01-01

    This Swedish Law reads as follows: "Section 1: this Law shall apply to the fertilization of a woman's egg outside her body, for the purpose of producing a child. Section 2: an egg which has been fertilized outside the body of a woman may not be introduced into her body unless: 1) the woman is married or living in a state of cohabitation; 2) the husband or cohabitant gives his written consent; and 3) the egg is the woman's own and has been fertilized with the sperm of her husband or cohabitant. Section 3: unless the authorization of the National Board of Health and Welfare is obtained, fertilization outside the human body may only be carried out in a general hospital. Section 4: persons committing a breach of Section 2 or 3 habitually or for gain shall be liable to a fine or to a prison sentence not exceeding six months." full text

  12. 49 CFR 238.429 - Safety appliances.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... appliance mechanical strength and fasteners. (1) All handrails, handholds, and sill steps shall be made of 1-inch diameter steel pipe, 5/8-inch thickness steel, or a material of equal or greater mechanical strength. (2) All safety appliances shall be securely fastened to the car body structure with mechanical...

  13. Evaluation of head and face injury potential of current airline seats during crash decelerations.

    DOT National Transportation Integrated Search

    1966-06-01

    A large percentage of deaths in commercial-airline crashes is produced as the body and lower limbs flail around the seat belt. According to a previous study, a 10-foot-diameter sphere of clear area would be necessary to prevent a person from striking...

  14. Thelohanellus toyamai infecting the gills of koi Cyprinus carpio in the eastern United States

    USDA-ARS?s Scientific Manuscript database

    A myxozoan resembling species of Thelohanellus was isolated from the gills of koi (Cyprinus carpio) cultured in North Carolina. Plasmodia measuring ~ 200µm in diameter contained tear-shaped myxospores containing a singly pyriform polar capsule. The spore body was concave on one side, measuring, 1...

  15. Theohanellus toyamai infecting the gills of Koi cyprinus carpio in the Eastern United States

    USDA-ARS?s Scientific Manuscript database

    A myxozoan resembling species of Thelohanellus was isolated from the gills of koi (Cyprinus carpio) cultured in North Carolina. Plasmodia measuring ~ 200µm in diameter contained tear-shaped myxospores containing a single pyriform polar capsule. The spore body was concave on one side, measuring 16....

  16. Effects of body conformation and udder morphology on milk yield of zebu cows in North region of Cameroon

    PubMed Central

    Mingoas, Kilekoung Jean-Pierre; Awah-Ndukum, Julius; Dakyang, Houinga; Zoli, Pagnah André

    2017-01-01

    Aim: The aim of the study was to assess the effect of udder morphological characteristics on milk yield in zebu cows of Cameroon. Materials and Methods: The diameter and height of the udder, length and diameter of the teat, and the milk yield were measured in 29 Djafun (Red Mbororo) and 19 Aku (White Fulani) cows in Louggueré zootechnical station in the North region of Cameroon. Results: Overall, strong positive correlation (rp=0.60) between the diameter (240.21±28.58 mm) and height (131.12±23.64 mm) of udders (p<0.001) and between length (39.51±6.44 mm) and diameter (19.85±3.08 mm) of teats (rp=0.78) were found in the zebu cows. Udder morphologic characteristics varied significantly (p<0.005) according to breed, lactation stage and parity, and height at whiters. There was significant (p<0.001) correlations between udder diameter (rp=0.541) and height (rp=0.549) with milk yield. Conclusion: This study ascertained udder morphological characteristics values in local zebu cows, and showed that udder size is strong and positively correlated to milk yield. The findings are useful in genetic improvement programs of zebu cows. PMID:28919680

  17. Properties of axially loaded implant-abutment assemblies using digital holographic interferometry analysis.

    PubMed

    Brozović, Juraj; Demoli, Nazif; Farkaš, Nina; Sušić, Mato; Alar, Zeljko; Gabrić Pandurić, Dragana

    2014-03-01

    The aim of this study was to (i) obtain the force-related interferometric patterns of loaded dental implant-abutment assemblies differing in diameter and brand using digital holographic interferometry (DHI) and (ii) determine the influence of implant diameter on the extent of load-induced implant deformation by quantifying and comparing the obtained interferometric data. Experiments included five implant brands (Ankylos, Astra Tech, blueSKY, MIS and Straumann), each represented by a narrow and a wide diameter implant connected to a corresponding abutment. A quasi-Fourier setup with a 25mW helium-neon laser was used for interferometric measurements in the cervical 5mm of the implants. Holograms were recorded in two conditions per measurement: a 10N preloaded and a measuring-force loaded assembly, resulting with an interferogram. This procedure was repeated throughout the whole process of incremental axial loading, from 20N to 120N. Each measurement series was repeated three times for each assembly, with complete dismantling of the implant-loading device in between. Additional software analyses calculated deformation data. Deformations were presented as mean values±standard deviations. Statistical analysis was performed using linear mixed effects modeling in R's lme4 package. Implants exhibited linear deformation patterns. The wide diameter group had lower mean deformation values than the narrow diameter group. The diameter significantly affected the deformation throughout loading sessions. This study gained in vitro implant performance data, compared the deformations in implant bodies and numerically stated the biomechanical benefits of wider diameter implants. Copyright © 2013 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. Robotic-arm assisted total hip arthroplasty results in smaller acetabular cup size in relation to the femoral head size: a matched-pair controlled study.

    PubMed

    Suarez-Ahedo, Carlos; Gui, Chengcheng; Martin, Timothy J; Chandrasekaran, Sivashankar; Lodhia, Parth; Domb, Benjamin G

    2017-03-31

    To compare the acetabular component size relative to the patient's native femoral head size between conventional THA (CTHA) approach and robotic-arm assisted THA (RTHA) to infer which of these techniques preserved more acetabular bone. Patients were included if they had primary osteoarthritis (OA) and underwent total hip replacement between June 2008 and March 2014. Patients were excluded if they had missing or rotated postoperative anteroposterior radiographs. RTHA patients were matched to a control group of CTHA patients, in terms of preoperative native femoral head size, age, gender, body mass index (BMI) and approach. Acetabular cup size relative to femoral head size was used as a surrogate for amount of bone resected. We compared the groups according to 2 measures describing acetabular cup diameter (c) in relation to femoral head diameter (f): (i) c-f, the difference between cup diameter and femoral head diameter and (ii) (c-f)/f, the same difference as a fraction of femoral head diameter. 57 matched pairs were included in each group. There were no significant differences between groups for demographic measures, femoral head diameter, or acetabular cup diameter (p>0.05). However, measures (i) and (ii) did differ significantly between the groups, with lower values in the RTHA group (p<0.02). Using acetabular cup size relative to femoral head size as an approximate surrogate measure of acetabular bone resection may suggest greater preservation of bone stock using RTHA compared to CTHA. Further studies are needed to validate the relationship between acetabular cup size and bone loss in THA.

  19. Method of synthesizing silica nanofibers using sound waves

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sharma, Jaswinder K.; Datskos, Panos G.

    A method for synthesizing silica nanofibers using sound waves is provided. The method includes providing a solution of polyvinyl pyrrolidone, adding sodium citrate and ammonium hydroxide to form a first mixture, adding a silica-based compound to the solution to form a second mixture, and sonicating the second mixture to synthesize a plurality of silica nanofibers having an average cross-sectional diameter of less than 70 nm and having a length on the order of at least several hundred microns. The method can be performed without heating or electrospinning, and instead includes less energy intensive strategies that can be scaled up tomore » an industrial scale. The resulting nanofibers can achieve a decreased mean diameter over conventional fibers. The decreased diameter generally increases the tensile strength of the silica nanofibers, as defects and contaminations decrease with the decreasing diameter.« less

  20. Method of synthesizing silica nanofibers using sound waves

    DOEpatents

    Sharma, Jaswinder K.; Datskos, Panos G.

    2015-09-15

    A method for synthesizing silica nanofibers using sound waves is provided. The method includes providing a solution of polyvinyl pyrrolidone, adding sodium citrate and ammonium hydroxide to form a first mixture, adding a silica-based compound to the solution to form a second mixture, and sonicating the second mixture to synthesize a plurality of silica nanofibers having an average cross-sectional diameter of less than 70 nm and having a length on the order of at least several hundred microns. The method can be performed without heating or electrospinning, and instead includes less energy intensive strategies that can be scaled up to an industrial scale. The resulting nanofibers can achieve a decreased mean diameter over conventional fibers. The decreased diameter generally increases the tensile strength of the silica nanofibers, as defects and contaminations decrease with the decreasing diameter.

  1. Impact experiments of porous gypsum-glass bead mixtures simulating parent bodies of ordinary chondrites: Implications for re-accumulation processes related to rubble-pile formation

    NASA Astrophysics Data System (ADS)

    Yasui, Minami; Arakawa, Masahiko

    2011-08-01

    Laboratory impact experiments were conducted for gypsum-glass bead targets simulating the parent bodies of ordinary chondrites. The effects of the chondrules included in the parent bodies on impact disruption were experimentally investigated in order to determine the impact conditions for the formation of rubble-pile bodies after catastrophic disruption. The targets included glass beads with a diameter ranging from 100 μm to 3 mm and the volume fraction was 0.6, similar to that of ordinary chondrites, which is about 0.65-0.75. Nylon projectiles with diameters of 10 mm and 2 mm were impacted at 60-180 m s -1 by a single-stage gas gun and at 4 km s -1 by a two-stage light gas gun, respectively. The impact strength of the gypsum-glass bead target was found to range from 56 to 116 J kg -1 depending on the glass bead size, and was several times smaller than that of the porous gypsum target, 446 J kg -1 in low-velocity collisions. The impact strengths of the 100 μm bead target and the porous gypsum target strongly depended on the impact velocity: those obtained in high-velocity collisions were several times greater than those obtained in low-velocity collisions. The velocities of fragments ejected from two corners on the impact surface of the target, measured in the center of the mass system, were slightly dependent on the target materials, irrespective of impact velocity. These results suggest that chondrule-including planetesimals (CiPs) can reconstruct rubble-pile bodies in catastrophic disruptions at the size of the planetesimal smaller than that of planetesimals without chondrules.

  2. Dynamics of liquid slug using particle image velocimetry technique

    NASA Astrophysics Data System (ADS)

    Siddiqui, M. I.; Aziz, A. Rashid A.; Heikal, M. R.

    2016-11-01

    Two phase liquid-gas slug flow is a source of vibration and fatigue on pipe walls and downstream equipment. This paper examines the effect of inlet conditions on the stream-wise velocity profiles and on the shear stresses induced by the liquid phase on the pipe wall during the slug flow. Instantaneous velocity vector fields of the liquid-gas (water-air) slug flow regime were obtained using particle image velocimetry (PIV) technique at various inlet conditions. A 6-m long Plexiglas pipe having an internal diameter 74-mm with a slight inclination of about 1.16° was considered for the visualization of the flow pattern. Test section was employed at a point 3.5m from the inlet, mounted with optical correction box filled with water to minimize the curvature effect of pipe on the PIV snapshots. Stream-wise velocity profiles are obtained at the wake of the liquid slug and the effect of inlet conditions were analyzed. A direct relationship was observed in between superficial gas velocity and the liquid stream-wise velocity at wake section of the slug flow. Further, the lower wall shear stresses were obtained using PIV velocity profiles at liquid film and the slug wake sections in a unit slug. The wall shear stress remained higher in the liquid slugy body as compared to the liquid film. Moreover, an increase in the wall shear stress was observed by increasing the gas superficial velocities.

  3. [Effects of sexual maturation on body composition, dermatoglyphics, somatotype and basic physical qualities of adolescents].

    PubMed

    Linhares, Renato Vidal; Matta, Marcelo de Oliveira; Lima, Jorge R P; Dantas, Paulo M Silva; Costa, Mônica Barros; Fernandes Filho, José

    2009-02-01

    Describe the characteristics of body composition, somatotype, basic physical qualities, dermatoglyphics and bone age regarding sexual maturation stages of boys. A transversal study was carried out in 136 boys, between 10 and 14 years of age. Clinical assessment, physical examination and radiography of wrists and hands to calculate bone age were performed. A tendency of increasing total body mass, stature, body mass index, body bone diameters and muscle circumferences and basic physical qualities was found with the advancing of puberty. No differences were found in dermatoglyphics and somatotype between different stages of puberty maturation. Due to the changes in important parameters of physical training that occur during puberty, it can be concluded that the selection of children and adolescents for sport training and competitions should be based not only on chronological age but also, and mainly on sexual maturation, for better physical assessment and appropriate training for this population.

  4. Influence of detector pixel size, TOF resolution and DOI on image quality in MR-compatible whole-body PET.

    PubMed

    Thoen, Hendrik; Keereman, Vincent; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2013-09-21

    The optimization of a whole-body PET system remains a challenging task, as the imaging performance is influenced by a complex interaction of different design parameters. However, it is not always clear which parameters have the largest impact on image quality and are most eligible for optimization. To determine this, we need to be able to assess their influence on image quality. We performed Monte-Carlo simulations of a whole-body PET scanner to predict the influence on image quality of three detector parameters: the TOF resolution, the transverse pixel size and depth-of-interaction (DOI)-correction. The inner diameter of the PET scanner was 65 cm, small enough to allow physical integration into a simultaneous PET-MR system. Point sources were used to evaluate the influence of transverse pixel size and DOI-correction on spatial resolution as function of radial distance. To evaluate the influence on contrast recovery and pixel noise a cylindrical phantom of 35 cm diameter was used, representing a large patient. The phantom contained multiple hot lesions with 5 mm diameter. These lesions were placed at radial distances of 50, 100 and 150 mm from the center of the field-of-view, to be able to study the effects at different radial positions. The non-prewhitening (NPW) observer was used for objective analysis of the detectability of the hot lesions in the cylindrical phantom. Based on this analysis the NPW-SNR was used to quantify the relative improvements in image quality due to changes of the variable detector parameters. The image quality of a whole-body PET scanner can be improved significantly by reducing the transverse pixel size from 4 to 2.6 mm and improving the TOF resolution from 600 to 400 ps and further from 400 to 200 ps. Compared to pixel size, the TOF resolution has the larger potential to increase image quality for the simulated phantom. The introduction of two layer DOI-correction only leads to a modest improvement for the spheres at radial distance of 150 mm from the center of the transaxial FOV.

  5. Did a Comet Deliver the Chelyabinsk Meteorite?

    NASA Astrophysics Data System (ADS)

    Gladysheva, O. G.

    2017-09-01

    An explosion of a celestial body occurred on the fifteenth of February, 2013, near Chelyabinsk (Russia). The explosive energy was determined as 500 kt of TNT, on the basis of which the mass of the bolide was estimated at 107 kg, and its diameter at 19 m [1]. Fragments of the meteorite, such as LL5/S4-WO type ordinary chondrite [2] with a total mass only of 2•103 kg, fell to the earth's surface [3]. Here, we will demonstrate that the deficit of the celestial body's mass can be explained by the arrival of the Chelyabinsk chondrite on Earth by a significantly more massive but fragile ice-bearing celestial body.

  6. TRAUMATIC (FOREIGN BODY) PERICARDITIS IN A TOCO TOUCAN (RAMPHASTOS TOCO).

    PubMed

    Máinez, Mireia; Rosell, Jorge; Such, Roger; Cardona, Teresa; Juan-Sallés, Carles

    2016-12-01

    An approximately 10-yr-old, captive-born female toco toucan ( Ramphastos toco ) was presented due to an acute onset of depression and apathy. On visual and physical examination, it showed an abnormal posture and dehydration, respectively. Serum biochemistry revealed hyperuricemia (39.4 mg/dl) and elevated glutamic oxaloacetic transaminase (GOT; 1,050 U/L). Radiographs demonstrated an enlargement of the cardiac silhouette. The bird died 7 days after presentation, despite treatment with enrofloxacin, allopurinol, a preparation of hepatorenal protectors, and complex B vitamins with dextrose. Necropsy revealed severe fibrinohemorrhagic pericarditis with a 15 mm long and 2.5 mm diameter, rigid foreign body in the pericardial exudate. Microscopically, this foreign body was of vegetal origin.

  7. 77 FR 33405 - Small Diameter Graphite Electrodes From the People's Republic of China: Affirmative Preliminary...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-06

    ...The Department of Commerce (``Department'') preliminarily determines that certain small diameter graphite electrodes (``SDGE'') are being exported from the United Kingdom (``U.K.'') to the United States by UK Carbon and Graphite Co., Ltd. (``UKCG'') in circumvention of the antidumping duty order on SDGE from the People's Republic of China (``PRC''),\\1\\ as provided in section 781(b) of the Tariff Act of 1930, as amended (``the Act''). ---------------------------------------------------------------------------

  8. Considerations on the Retrieval of Plume Particle Properties from the AFRPL Transmissometer and Polarization-Scattering Experiments.

    DTIC Science & Technology

    1984-08-01

    transmissometer experiment. In these measure - ments, simple transmission measurements of laser radiation through a diameter of the plume are made. With...Air Force Rocket Propulsion Laboratory4{AFRPL). In one experiment, simple laser transmission measurements are made over a full diameter line of sight...consist of measure - ments of the polarization of laser radiation which has been scattered by plume particulates. The analysis is presented in Section

  9. Method for interconverting drying and heating times between round and square cross sections of ponderosa pine

    Treesearch

    William T. Simpson

    2005-01-01

    To use small-diameter trees effectively as square timbers, we need to be able to estimate the amount of time it takes for these timbers to air-dry. Since experimental data on estimating air-drying time for small-diameter logs have been developed, this study looked at a way to relate that method to square timbers. Drying times were determined for a group of round cross-...

  10. Heat transfer enhancement and entropy generation analysis of Al2O3-water nanofluid in an alternating oval cross-section tube using two-phase mixture model under turbulent flow

    NASA Astrophysics Data System (ADS)

    Najafi Khaboshan, Hasan; Nazif, Hamid Reza

    2018-04-01

    Heat transfer and turbulent flow of Al2O3-water nanofluid within alternating oval cross-section tube are numerically simulated using Eulerian-Eulerian two-phase mixture model. The primary goal of the present study is to investigate the effects of nanoparticles volume fraction, nanoparticles diameter and different inlet velocities on heat transfer, pressure drop and entropy generation characteristics of the alternating oval cross-section tube. For numerical simulation validation, the numerical results were compared with experimental data. Also, constant wall temperature boundary condition was considered on the tube wall. In addition, the comparison of thermal-hydraulic performance and the entropy generation characteristics between alternating oval cross-section tube and circular tube under same fluids were done. The results show that the heat transfer coefficient and pressure drop of alternating oval cross-section tube is more than base tube under same fluids. Also, these two parameters are increased when adding Al2O3 nanoparticle into water fluid, at any inlet velocity for both tubes. Furthermore, compared to the base fluid, the value of the heat transfer enhancement of nanofluid is higher than the increase of friction factor of nanofluid at the same given inlet boundary conditions. The results of entropy generation analysis illustrate that the total entropy generation increase with increasing the nanoparticles volume fraction and decreasing the nanoparticles diameter of nanofluid. The generation of thermal entropy is the main part of irreversibility, and Bejan number with an increase of the nanoparticles diameter slightly increases. Finally, at any given inlet velocity the frictional irreversibility is grown with an increase the nanoparticles volume fraction.

  11. Design and fabrication of conventional and unconventional superconductors

    NASA Technical Reports Server (NTRS)

    Collings, E. W.

    1983-01-01

    The design and fabrication of conventional and unconventionally processed Ti-Nb base and Al5-compound-base, respectively, composite superconductors is discussed in a nine section review. The first two sections introduce the general properties of alloy and compound superconductors, and the design and processing requirements for the production of long lengths of stable low loss conductor. All aspects of flux jump stability, and the general requirements of cryogenic stabilization are addressed. Conductor design from an a.c.-loss standpoint; some basic formulae describing hysteretic and eddy current losses and the influences on a.c. loss of filament diameter, strand (conductor) diameter, twist pitch, and matrix resistivity are discussed. The basic techniques used in the fabrication of conventional multifilamentary conductors are described.

  12. Verification of the FBR fuel bundle-duct interaction analysis code BAMBOO by the out-of-pile bundle compression test with large diameter pins

    NASA Astrophysics Data System (ADS)

    Uwaba, Tomoyuki; Ito, Masahiro; Nemoto, Junichi; Ichikawa, Shoichi; Katsuyama, Kozo

    2014-09-01

    The BAMBOO computer code was verified by results for the out-of-pile bundle compression test with large diameter pin bundle deformation under the bundle-duct interaction (BDI) condition. The pin diameters of the examined test bundles were 8.5 mm and 10.4 mm, which are targeted as preliminary fuel pin diameters for the upgraded core of the prototype fast breeder reactor (FBR) and for demonstration and commercial FBRs studied in the FaCT project. In the bundle compression test, bundle cross-sectional views were obtained from X-ray computer tomography (CT) images and local parameters of bundle deformation such as pin-to-duct and pin-to-pin clearances were measured by CT image analyses. In the verification, calculation results of bundle deformation obtained by the BAMBOO code analyses were compared with the experimental results from the CT image analyses. The comparison showed that the BAMBOO code reasonably predicts deformation of large diameter pin bundles under the BDI condition by assuming that pin bowing and cladding oval distortion are the major deformation mechanisms, the same as in the case of small diameter pin bundles. In addition, the BAMBOO analysis results confirmed that cladding oval distortion effectively suppresses BDI in large diameter pin bundles as well as in small diameter pin bundles.

  13. Mean Normal Portal Vein Diameter Using Sonography among Clients Coming to Radiology Department of Jimma University Hospital, Southwest Ethiopia.

    PubMed

    Geleto, Gemechu; Getnet, Wondim; Tewelde, Tsegaye

    2016-05-01

    Mean portal vein diameter is considered as the best indicator for portal hypertension. However, the cutoff point differs from study to study (above 10-15 mm) despite the existence of normal mean portal vein diameter between 10-15 mm in different settings.This implies the existence of limited evidence on normal portal vein diameter for all populations in all countries prior to setting the cutoff points. Therefore, the aim of this study was sonographic assessment of normal mean portal vein diameter among patients referred to The Department of Radiology in Jimma University Hospital. A facility based cross-sectional study was conducted from November to December 2014 at Jimma University Hospital on a total of 195 clients. Data about portal vein diameter for eligible clients were collected by radiologists using Sonography. Data were edited manually, entered and analyzed using SPSS version 16. Data were collected from a total of 195 participants. Among these, 121(62.1%) were males and the median age of the participants was 35 years. The study revealed a normal mean portal vein diameter of 10.6 mm ±1.8 SD with a respirophasic variation of 25.6%. Likewise, the normal mean portal vein diameter seemed to have varied significantly by age and sex. The study revealed a normal mean portal vein diameter ranging below 13 mm. Hence, decisions made in clinical settings should base on these findings. Besides, there is a need for large scale study to determine portal vein diameter variation by age and sex, controlling other confounders.

  14. Altitude Wind Tunnel at the NACA’s Aircraft Engine Research Laboratory

    NASA Image and Video Library

    1945-06-21

    Two men on top of the Altitude Wind Tunnel (AWT) at the National Advisory Committee for Aeronautics (NACA) Aircraft Engine Research Laboratory. The tunnel was a massive rectangular structure, which for years provided one of the highest vantage points on the laboratory. The tunnel was 263 feet long on the north and south legs and 121 feet long on the east and west sides. The larger west end of the tunnel, seen here, was 51 feet in diameter. The east side of the tunnel was 31 feet in diameter at the southeast corner and 27 feet in diameter at the northeast. The throat section, which connected the northwest corner to the test section, narrowed sharply from 51 to 20 feet in diameter. The AWT’s altitude simulation required temperature and pressure fluctuations that made the design of the shell more difficult than other tunnels. The simultaneous decrease in both pressure and temperature inside the facility produced uneven stress loads, particularly on the support rings. The steel used in the primary tunnel structure was one inch thick to ensure that the shell did not collapse as the internal air pressure was dropped to simulate high altitudes. It was a massive amount of steel considering the World War II shortages. The shell was covered with several inches of fiberglass insulation to retain the refrigerated air and a thinner outer steel layer to protect the insulation against the weather. A unique system of rollers was used between the shell and its support piers. These rollers allowed for movement as the shell expanded or contracted during the altitude simulations. Certain sections would move as much as five inches during operation.

  15. A Novel Tool for Simulating Aerosol-cloud Interactions with a Sectional Model Implemented to a Large-Eddy Simulator

    NASA Astrophysics Data System (ADS)

    Tonttila, J.; Romakkaniemi, S.; Kokkola, H.; Maalick, Z.; Korhonen, H.; Liqing, H.

    2015-12-01

    A new cloud-resolving model setup for studying aerosol-cloud interactions, with a special emphasis on partitioning and wet deposition of semi-volatile aerosol species, is presented. The model is based on modified versions of two well-established model components: the Large-Eddy Simulator (LES) UCLALES, and the sectional aerosol model SALSA, previously employed in the ECHAM climate model family. Implementation of the UCLALES-SALSA is described in detail. As the basis for this work, SALSA has been extended to include a sectional representation of the size distributions of cloud droplets and precipitation. Microphysical processes operating on clouds and precipitation have also been added. Given our main motivation, the cloud droplet size bins are defined according to the dry particle diameter. The droplet wet diameter is solved dynamically through condensation equations, but represents an average droplet diameter inside each size bin. This approach allows for accurate tracking of the aerosol properties inside clouds, but minimizes the computational cost. Since the actual cloud droplet diameter is not fully resolved inside the size bins, processes such as precipitation formation rely on parameterizations. For realistic growth of drizzle drops to rain, which is critical for the aerosol wet deposition, the precipitation size bins are defined according to the actual drop size. With these additions, the implementation of the SALSA model replaces most of the microphysical and thermodynamical components within the LES. The cloud properties and aerosol-cloud interactions simulated by the model are analysed and evaluated against detailed cloud microphysical boxmodel results and in-situ aerosol-cloud interaction observations from the Puijo measurement station in Kuopio, Finland. The ability of the model to reproduce the impacts of wet deposition on the aerosol population is demonstrated.

  16. Comparative analysis of Meissner's corpuscles in the fingertips of primates.

    PubMed

    Verendeev, Andrey; Thomas, Christian; McFarlin, Shannon C; Hopkins, William D; Phillips, Kimberley A; Sherwood, Chet C

    2015-07-01

    Meissner's corpuscles (MCs) are tactile mechanoreceptors found in the glabrous skin of primates, including fingertips. These receptors are characterized by sensitivity to light touch, and therefore might be associated with the evolution of manipulative abilities of the hands in primates. We examined MCs in different primate species, including common marmoset (Callithrix jacchus, n = 5), baboon (Papio anubis, n = 2), rhesus macaque (Macaca mulatta, n = 3), chimpanzee (Pan troglodytes, n = 3), bonobo (Pan paniscus, n = 1) and human (Homo sapiens, n = 8). Fingertips of the first, second and fourth digits were collected from both hands of specimens, dissected and histologically stained using hematoxylin and eosin. The density (MCs per 1 mm(2) ) and the size (cross-sectional diameter of MCs) were quantified. Overall, there were no differences in the densities of MCs or their size among the digits or between the hands for any species examined. However, MCs varied across species. We found a trend for higher densities of MCs in macaques and humans compared with chimpanzees and bonobos; moreover, apes had larger MCs than monkeys. We further examined whether the density or size of MCs varied as a function of body mass, measures of dexterity and dietary frugivory. Among these variables, only body size accounted for a significant amount of variation in the size of MCs. © 2015 Anatomical Society.

  17. Bodies with noncircular cross sections and bank-to-turn missiles

    NASA Technical Reports Server (NTRS)

    Jackson, C. M., Jr.; Sawyer, W. C.

    1986-01-01

    An evaluation is made of prospective missile applications for noncircular cross section bodies, and of recent developments in bank-to-turn missile configuration aerodynamics. The discussion encompasses cross-flow analysis techniques, as well as study results obtained for bodies with elliptical and square cross sections and with variable cross sections. Attention is given to both the performance advantages and the stability and control problems of bank-to-turn missile configurations; the aerodynamic data presented for monoplanar configurations extend to those incorporating airbreathing propulsion systems.

  18. Relationship between central and peripheral corneal astigmatism in elderly patients

    NASA Astrophysics Data System (ADS)

    Kawamorita, Takushi; Shimizu, Kimiya; Hoshikawa, Rie; Kamiya, Kazutaka; Shoji, Nobuyuki

    2018-03-01

    Abstract Purpose We investigated the relationship between central and peripheral corneal astigmatism in elderly patients. Methods Seventy-six eyes of 76 elderly subjects (mean age = 72.6 ± 3.0 years) were included in the study. Corneal shape was evaluated using the Pentacam HR (Oculus, Wetzlark, Germany), which is comprised of a rotating Scheimpflug camera and a short-wavelength slit light. The power distribution map was selected and corneal astigmatism was calculated using front K-Readings in zones centered on the pupil. Analyzed zones were 2.0-6.0 mm in diameter. Results Corneal astigmatism decreased as diameter increased, similar to what was observed in eyes with with-the-rule astigmatism and against-the-rule astigmatism (ANOVA, p < 0.01). This effect was more pronounced in eyes with a large central corneal astigmatism (Spearman's rank-correlation coefficient test, r = 0.51, p < 0.01). There was no change as to axis of corneal astigmatism (ANOVA, p = 0.98). Conclusion These results suggest that the relationship between central and peripheral corneal astigmatism should be taken into consideration to optimize vision when astigmatic correction is needed.

  19. A study of the effect of pregnancy on muscle fibers of the rectus abdominis muscle of the rat.

    PubMed

    Martin, W D

    1979-11-01

    Samples of the rectus abdominis muscle were taken from Sprague-Dawley rats at 0, 3, 6, 6, 12, 15, 18, and 21 days of pregnancy, and at 1, 3, 6, 9, 12, and 15 days of postpartum. Sections were incubated for actomyosin adenosine triphosphatase activity following preincubation at a basic pH. Muscle fibers within a unit area of each sample were identified as to fiber type according to their enzyme activity, and the population of each type counted. The proportion of each fiber type was calculated and the diameter of 24 fibers of each type measured. No changes were noted in the muscle fiber proportions through the course of the experiment. Differential changes in muscle fiber diameters were noted in each of the three muscle fiber types. Slow oxidative fibers underwent an increase in diameter through the last half of pregnancy. The diameter was further increased as stretch of the muscle was released after birth, and did not decrease in the postpartum period. Fast glycolytic fibers decreased in diameter during the last half of pregnancy, but returned to the prepregnancy diameter in the first postpartum day. The diameter of the fast oxidative glycolytic fibers remained unchanged through the course of pregnacy and in the postpartum period.

  20. Relation of female sex to left atrial diameter and cardiovascular death in atrial fibrillation: The AFFIRM Trial.

    PubMed

    Proietti, Marco; Raparelli, Valeria; Basili, Stefania; Olshansky, Brian; Lip, Gregory Y H

    2016-03-15

    Female sex is associated with thromboembolism related to atrial fibrillation (AF). Left atrial (LA) diameter independently predicted incident cardiovascular (CV) major events in the general population. In AF patients, LA enlargement is associated to AF occurrence and recurrence. No data have previously been reported on the relationship between LA enlargement, sex and CV death in AF patients. All patients enrolled in the AFFIRM Trial with available data about LA dimension were included in this post-hoc analysis. Of the 2615 eligible for the present analysis, LA enlargement was recorded in 67.0%, more commonly in women than in men (p=0.032). Patients with LA enlargement had higher body mass index (BMI), and were more frequently hypertensive, diabetic, and diagnosed with a structural heart disease, prior coronary artery disease (CAD) and heart failure (HF). BMI, left ventricular mass, female sex and mitral valve insufficiency (p<0.001) were associated with LA enlargement. AF female patients with LA enlargement had a higher risk for CV death (p=0.011). LA diameter showed a significant association with CV death (p<0.001). Cox regression analysis demonstrated that LA diameter was an independent predictor of CV death in female AF patients (p=0.003). LA diameter enlargement is associated with female sex, and carries a higher risk for CV death, particularly in females. LA diameter was an independent predictor of CV death in female AF patients. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  1. Prediction of Performance of Diamond Wire Saw with Respect to Texture Characteristics of Rock / Prognozowanie Wydajności Pracy Strunowej Piły Diamentowej W Odniesieniu Do Charakterystyki Tekstury Skał

    NASA Astrophysics Data System (ADS)

    Ghaysari, N.; Ataei, M.; Sereshki, F.; Mikaiel, R.

    2012-12-01

    In this study, prediction of production rate in diamond wire saw has been investigated. Performance measurements of diamond wire saw carried out in 7 different quarries of carbonate rocks in Iran. For determination textural properties, rock samples were collected from these quarries. At first, a thin section was prepared for each rock and then 5 digital photographs were taken from each section. After this, all images were digitized using AutoCAD software. Then, area, perimeter, longest diameter and shortest diameter were assigned. According to these parameters, all of the other textural characteristics and texture coefficient were determined too. The correlation between sawing rate and textural characteristics were evaluated using multiple and simple regression analyses. Then developed model was validated by P-value test. It was concluded that area, perimeter, diameter equivalent and index of grain size homogeneity are very effective on production rate. Production rate using diamond wire saw can reliably be predicted using developed model.

  2. Statistical variability study of random dopant fluctuation on gate-all-around inversion-mode silicon nanowire field-effect transistors

    NASA Astrophysics Data System (ADS)

    Yoon, Jun-Sik; Rim, Taiuk; Kim, Jungsik; Kim, Kihyun; Baek, Chang-Ki; Jeong, Yoon-Ha

    2015-03-01

    Random dopant fluctuation effects of gate-all-around inversion-mode silicon nanowire field-effect transistors (FETs) with different diameters and extension lengths are investigated. The nanowire FETs with smaller diameter and longer extension length reduce average values and variations of subthreshold swing and drain-induced barrier lowering, thus improving short channel immunity. Relative variations of the drain currents increase as the diameter decreases because of decreased current drivability from narrower channel cross-sections. Absolute variations of the drain currents decrease critically as the extension length increases due to decreasing the number of arsenic dopants penetrating into the channel region. To understand variability origins of the drain currents, variations of source/drain series resistance and low-field mobility are investigated. All these two parameters affect the variations of the drain currents concurrently. The nanowire FETs having extension lengths sufficient to prevent dopant penetration into the channel regions and maintaining relatively large cross-sections are suggested to achieve suitable short channel immunity and small variations of the drain currents.

  3. Void fraction development in gas-liquid flow after a U-bend in a vertically upwards serpentine-configuration large-diameter pipe

    NASA Astrophysics Data System (ADS)

    Almabrok, Almabrok A.; Aliyu, Aliyu M.; Baba, Yahaya D.; Lao, Liyun; Yeung, Hoi

    2018-01-01

    We investigate the effect of a return U-bend on flow behaviour in the vertical upward section of a large-diameter pipe. A wire mesh sensor was employed to study the void fraction distributions at axial distances of 5, 28 and 47 pipe diameters after the upstream bottom bend. The study found that, the bottom bend has considerable impacts on up-flow behaviour. In all conditions, centrifugal action causes appreciable misdistribution in the adjacent straight section. Plots from WMS measurements show that flow asymmetry significantly reduces along the axis at L/D = 47. Regime maps generated from three axial locations showed that, in addition to bubbly, intermittent and annular flows, oscillatory flow occurred particularly when gas and liquid flow rates were relatively low. At this position, mean void fractions were in agreement with those from other large-pipe studies, and comparisons were made with existing void fraction correlations. Among the correlations surveyed, drift flux-type correlations were found to give the best predictive results.

  4. 41 CFR 102-37.565 - What is the authority for donations to public bodies?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... for donations to public bodies? 102-37.565 Section 102-37.565 Public Contracts and Property Management... 37-DONATION OF SURPLUS PERSONAL PROPERTY Donations to Public Bodies in Lieu of Abandonment/Destruction § 102-37.565 What is the authority for donations to public bodies? Section 527 of title 40, United...

  5. 41 CFR 102-37.565 - What is the authority for donations to public bodies?

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... for donations to public bodies? 102-37.565 Section 102-37.565 Public Contracts and Property Management... 37-DONATION OF SURPLUS PERSONAL PROPERTY Donations to Public Bodies in Lieu of Abandonment/Destruction § 102-37.565 What is the authority for donations to public bodies? Section 527 of title 40, United...

  6. 41 CFR 102-37.565 - What is the authority for donations to public bodies?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... for donations to public bodies? 102-37.565 Section 102-37.565 Public Contracts and Property Management... 37-DONATION OF SURPLUS PERSONAL PROPERTY Donations to Public Bodies in Lieu of Abandonment/Destruction § 102-37.565 What is the authority for donations to public bodies? Section 527 of title 40, United...

  7. 41 CFR 102-37.565 - What is the authority for donations to public bodies?

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... for donations to public bodies? 102-37.565 Section 102-37.565 Public Contracts and Property Management... 37-DONATION OF SURPLUS PERSONAL PROPERTY Donations to Public Bodies in Lieu of Abandonment/Destruction § 102-37.565 What is the authority for donations to public bodies? Section 527 of title 40, United...

  8. 41 CFR 102-37.565 - What is the authority for donations to public bodies?

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... for donations to public bodies? 102-37.565 Section 102-37.565 Public Contracts and Property Management... 37-DONATION OF SURPLUS PERSONAL PROPERTY Donations to Public Bodies in Lieu of Abandonment/Destruction § 102-37.565 What is the authority for donations to public bodies? Section 527 of title 40, United...

  9. Vesta and Ceres

    NASA Astrophysics Data System (ADS)

    Righter, Kevin

    2018-04-01

    Asteroids 1 Ceres and 4 Vesta are the two largest asteroids in the asteroid belt, with mean diameters of 946 km and 525 km, respectively. Ceres was reclassified as a dwarf planet by the IAU (International Astronomical Union) as a result of their new dwarf planet definition, which is a body that (a) orbits the sun, (b) has enough mass to assume a nearly round shape, (c) has not cleared the neighborhood around its orbit, and (d) is not a moon. Our understanding of these two bodies has been revolutionized in the last decade by the success of the Dawn mission that visited both bodies. Vesta is an example of a small body that has been heated substantially, and differentiated into a metallic core, silicate mantle, and basaltic crust. Ceres is a volatile-rich rocky body that did not experience significant heating and therefore has only partially differentiated. These two contrasting bodies have been instrumental in learning how inner solar system material formed and evolved.

  10. Sonic boom generated by a slender body aerodynamically shaded by a disk spike

    NASA Astrophysics Data System (ADS)

    Potapkin, A. V.; Moskvichev, D. Yu.

    2018-03-01

    The sonic boom generated by a slender body of revolution aerodynamically shaded by another body is numerically investigated. The aerodynamic shadow is created by a disk placed upstream of the slender body across a supersonic free-stream flow. The disk size and its position upstream of the body are chosen in such a way that the aerodynamically shaded flow is quasi-stationary. A combined method of phantom bodies is used for sonic boom calculations. The method is tested by calculating the sonic boom generated by a blunted body and comparing the results with experimental investigations of the sonic boom generated by spheres of various diameters in ballistic ranges and wind tunnels. The test calculations show that the method of phantom bodies is applicable for calculating far-field parameters of shock waves generated by both slender and blunted bodies. A possibility of reducing the shock wave intensity in the far field by means of the formation of the aerodynamic shadow behind the disk placed upstream of the body is estimated. The calculations are performed for the incoming flow with the Mach number equal to 2. The effect of the disk size on the sonic boom level is calculated.

  11. Lunar Regolith Particle Shape Analysis

    NASA Technical Reports Server (NTRS)

    Kiekhaefer, Rebecca; Hardy, Sandra; Rickman, Douglas; Edmunson, Jennifer

    2013-01-01

    Future engineering of structures and equipment on the lunar surface requires significant understanding of particle characteristics of the lunar regolith. Nearly all sediment characteristics are influenced by particle shape; therefore a method of quantifying particle shape is useful both in lunar and terrestrial applications. We have created a method to quantify particle shape, specifically for lunar regolith, using image processing. Photomicrographs of thin sections of lunar core material were obtained under reflected light. Three photomicrographs were analyzed using ImageJ and MATLAB. From the image analysis measurements for area, perimeter, Feret diameter, orthogonal Feret diameter, Heywood factor, aspect ratio, sieve diameter, and sieve number were recorded. Probability distribution functions were created from the measurements of Heywood factor and aspect ratio.

  12. Initial diameter of the polar body contractile ring is minimized by the centralspindlin complex.

    PubMed

    Fabritius, Amy S; Flynn, Jonathan R; McNally, Francis J

    2011-11-01

    Polar body formation is an essential step in forming haploid eggs from diploid oocytes. This process involves completion of a highly asymmetric cytokinesis that results in a large egg and two small polar bodies. Unlike mitotic contractile rings, polar body contractile rings assemble over one spindle pole so that the spindle must move through the contractile ring before cytokinesis. During time-lapse imaging of C. elegans meiosis, the contractile ring moved downward along the length of the spindle and completed scission at the midpoint of the spindle, even when spindle length or rate of ring movement was increased. Patches of myosin heavy chain and dynamic furrowing of the plasma membrane over the entire embryo suggested that global cortical contraction forces the meiotic spindle and overlying membrane out through the contractile ring center. Consistent with this model, depletion of myosin phosphatase increased the velocity of ring movement along the length of the spindle. Global dynamic furrowing, which was restricted to anaphase I and II, was dependent on myosin II, the anaphase promoting complex and separase, but did not require cortical contact by the spindle. Large cortical patches of myosin during metaphase I and II indicated that myosin was already in the active form before activation of separase. To identify the signal at the midpoint of the anaphase spindle that induces scission, we depleted two proteins that mark the exact midpoint of the spindle during late anaphase, CYK-4 and ZEN-4. Depletion of either protein resulted in the unexpected phenotype of initial ingression of a polar body ring with twice the diameter of wild type. This phenotype revealed a novel mechanism for minimizing polar body size. Proteins at the spindle midpoint are required for initial ring ingression to occur close to the membrane-proximal spindle pole. 2011 Elsevier Inc. All rights reserved.

  13. Myocardial myostatin in spontaneously hypertensive rats with heart failure.

    PubMed

    Damatto, R L; Lima, A R R; Martinez, P F; Cezar, M D M; Okoshi, K; Okoshi, M P

    2016-07-15

    Myostatin has been shown to regulate skeletal and cardiac muscle growth. However, its status on long-term hypertrophied myocardium has not been addressed. The purpose of this study was to evaluate the expression of myocardial myostatin and its antagonist follistatin in spontaneously hypertensive rats (SHR) with heart failure. Eighteen-month-old SHR were evaluated to identify clinical features of heart failure such as tachypnea/labored respiration and weight loss. After heart failure was detected, rats were subjected to echocardiogram and euthanized. Age-matched normotensive Wistar-Kyoto (WKY) rats were used as controls. Myostatin and follistatin protein expression was assessed by Western blotting. Statistical analysis was performed by Student's t test. All SHR (n=8) presented right ventricular hypertrophy and five had lung congestion. SHR had left chambers hypertrophy and dilation (left atrial diameter: WKY 5.73±0.59; SHR 7.28±1.17mm; p=0.004; left ventricular (LV) diastolic diameter/body weight ratio: WKY 19.6±3.1; SHR 27.7±4.7mm/kg; p=0.001), and LV systolic dysfunction (midwall fractional shortening: WKY 34.9±3.31; SHR 24.8±3.20%; p=0.003). Myocyte diameter (WKY 23.1±1.50, SHR 25.5±1.33μm; p=0.004) and myocardial interstitial collagen fraction (WKY 4.86±0.01; SHR 8.36±0.02%; p<0.001) were increased in the SHR. Myostatin (WKY 1.00±0.16; SHR 0.77±0.23 arbitrary units; p=0.035) and follistatin (WKY 1.00±0.35; SHR 0.49±0.18 arbitrary units; p=0.002) expression was lower in SHR. Myostatin and follistatin expression negatively correlated with LV diastolic diameter-to-body weight ratio and LV systolic diameter, and positively correlated with midwall fractional shortening. Myostatin and follistatin protein expression is reduced in the long-term hypertrophied myocardium from spontaneously hypertensive rats with heart failure. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  14. Estimating aspen crown fuels in northeastern Minnesota.

    Treesearch

    Robert M. Loomis; Peter J. Roussopoulos

    1978-01-01

    An application section presents tables for estimating foliage and branchwood (wood plus bark) of aspen tree crowns; the branchwood is subdivided by (1) living and dead material and by (2) living material alone into diameter size groups. A documentation section describes the derivation of equations and compares the equations derived with those derived by other...

  15. Drive system for the retraction/extension of variable diameter rotor systems

    NASA Technical Reports Server (NTRS)

    Gmirya, Yuriy (Inventor)

    2003-01-01

    A drive system for a variable diameter rotor (VDR) system includes a plurality of rotor blade assemblies with inner and outer rotor blade segments. The outer blade segment being telescopically mounted to the inner blade segment. The VDR retraction/extension system includes a drive housing mounted at the root of each blade. The housing supports a spool assembly, a harmonic gear set and an electric motor. The spool assembly includes a pair of counter rotating spools each of which drive a respective cable which extends through the interior of the inboard rotor blade section and around a pulley mounted to the outboard rotor blade section. In operation, the electric motor drives the harmonic gear set which rotates the counter rotating spools. Rotation of the spools causes the cables to be wound onto or off their respective spool consequently effecting retraction/extension of the pulley and the attached outboard rotor blade section relative the inboard rotor blade section. As each blade drive system is independently driven by a separate electrical motor, each independent VDR blade assembly is independently positionable.

  16. Dependence of light scattering profile in tissue on blood vessel diameter and distribution: a computer simulation study.

    PubMed

    Duadi, Hamootal; Fixler, Dror; Popovtzer, Rachela

    2013-11-01

    Most methods for measuring light-tissue interactions focus on the volume reflectance while very few measure the transmission. We investigate both diffusion reflection and diffuse transmission at all exit angles to receive the full scattering profile. We also investigate the influence of blood vessel diameter on the scattering profile of a circular tissue. The photon propagation path at a wavelength of 850 nm is calculated from the absorption and scattering constants via Monte Carlo simulation. Several simulations are performed where a different vessel diameter and location were chosen but the blood volume was kept constant. The fraction of photons exiting the tissue at several central angles is presented for each vessel diameter. The main result is that there is a central angle that below which the photon transmission decreased for lower vessel diameters while above this angle the opposite occurred. We find this central angle to be 135 deg for a two-dimensional 10-mm diameter circular tissue cross-section containing blood vessels. These findings can be useful for monitoring blood perfusion and oxygen delivery in the ear lobe and pinched tissues. © 2013 Society of Photo-Optical Instrumentation Engineers (SPIE)

  17. Design of New Muzzle for 80mm Diamter Single-Stage Gas Gun

    NASA Astrophysics Data System (ADS)

    Russell, R. T.; Starks, K. S.; Grote, D. L., II; Vandersall, K. S.; Zhou, M.; Thadhani, N. N.

    1999-06-01

    In this paper, we describe the design of a new muzzle for the Georgia Institute of Technology's 80mm diameter single-stage gas gun. The muzzle is designed to accommodate both normal and inclined impact experiments. Modular target-holding assemblies are mounted on a hardened tool steel annular plate 3 inches in thickness and 15 inches in diameter. This plate is threaded on to the gun barrel and locked into place by an anti-backlash assembly to prevent loss of alignment. The target mount for normal impact experiments consists of two 4.5 inch diameter semi-cylindrical ring sections with surfaces lapped perpendicular to the major bore axis. The inclined target mount includes a pair of concentric cylinder sections with an inner diameter of 8 inches. Tilt adjustment is achieved around two mutually perpendicular and intersecting axis of rotation, as in a gimbals assembly. Coarse alignment allows for angles between -10 and +30 degrees. Fine alignment is achieved using 3/8 inch machine screws with 40 threads per inch. This mechanism yields a precision of 0.025 inches per revolution, the same precision found in a micrometer. The linear distance between the adjustment mechanisms and the axes of rotation geometrically enhances fine alignment. Velocity measurement assemblies using shear pins, time of arrival pins, and laser/photo-diode circuits are designed as bolt-on modules.

  18. Advanced Antennas Enabled by Electromagnetic Metamaterials

    DTIC Science & Technology

    2014-12-01

    radiation patterns of a conical horn antenna and three soft horns with various homogeneous metasurface liners. The maximum cross-polarization level was...inhomogencous metasurface liners covering both the flared horn section and the straight waveguide section. The mctahorn is fed by a circular waveguide...with a diameter of 20 mm. (b) The sizes of the metallic patches at each row of the metasurface in the flared horn section. Both the length and width

  19. Undercuts by Laser Shock Forming

    NASA Astrophysics Data System (ADS)

    Wielage, Hanna; Vollertsen, Frank

    2011-05-01

    In laser shock forming TEA-CO2-laser induced shock waves are used to form metal foils, such as aluminum or copper. The process utilizes an initiated plasma shock wave on the target surface, which leads to a forming of the foil. A challenge in forming technologies is the manufacturing of undercuts. By conventional forming methods these special forms are not feasible. In this article, it is presented that undercuts in the micro range can be produced by laser shock deep drawing. Different drawing die diameters, drawing die depths and the material aluminum in the thicknesses 20 and 50 μm were investigated. It will be presented that smaller die diameters facilitate undercuts compared to bigger die diameters. The phenomena can be explained by Barlow's formula. Furthermore, it is shown which maximum undercut depth at different die diameters can be reached. To this end, cross-sections of the different parameter combinations are displayed.

  20. Influence of end plates on aerodynamic characteristics of bluff bodies

    NASA Astrophysics Data System (ADS)

    Shmigirilov, Rodion; Ryabinin, Anatoly

    2018-05-01

    Aerodynamic characteristics of flat plate oriented normally to the flow are studied in the wind tunnel. The experiments are carried out without end plates and with round end plates of different diameter. We obtain that end plates increase the base pressure, the drag coefficient and decrease the length of recirculation region.

Top