Sample records for diameter distance da

  1. Light propagation in Swiss-cheese models of random close-packed Szekeres structures: Effects of anisotropy and comparisons with perturbative results

    NASA Astrophysics Data System (ADS)

    Koksbang, S. M.

    2017-03-01

    Light propagation in two Swiss-cheese models based on anisotropic Szekeres structures is studied and compared with light propagation in Swiss-cheese models based on the Szekeres models' underlying Lemaitre-Tolman-Bondi models. The study shows that the anisotropy of the Szekeres models has only a small effect on quantities such as redshift-distance relations, projected shear and expansion rate along individual light rays. The average angular diameter distance to the last scattering surface is computed for each model. Contrary to earlier studies, the results obtained here are (mostly) in agreement with perturbative results. In particular, a small negative shift, δ DA≔D/A-DA ,b g DA ,b g , in the angular diameter distance is obtained upon line-of-sight averaging in three of the four models. The results are, however, not statistically significant. In the fourth model, there is a small positive shift which has an especially small statistical significance. The line-of-sight averaged inverse magnification at z =1100 is consistent with 1 to a high level of confidence for all models, indicating that the area of the surface corresponding to z =1100 is close to that of the background.

  2. CMB seen through random Swiss Cheese

    NASA Astrophysics Data System (ADS)

    Lavinto, Mikko; Räsänen, Syksy

    2015-10-01

    We consider a Swiss Cheese model with a random arrangement of Lemaȋtre-Tolman-Bondi holes in ΛCDM cheese. We study two kinds of holes with radius rb=50 h-1 Mpc, with either an underdense or an overdense centre, called the open and closed case, respectively. We calculate the effect of the holes on the temperature, angular diameter distance and, for the first time in Swiss Cheese models, shear of the CMB . We quantify the systematic shift of the mean and the statistical scatter, and calculate the power spectra. In the open case, the temperature power spectrum is three orders of magnitude below the linear ISW spectrum. It is sensitive to the details of the hole, in the closed case the amplitude is two orders of magnitude smaller. In contrast, the power spectra of the distance and shear are more robust, and agree with perturbation theory and previous Swiss Cheese results. We do not find a statistically significant mean shift in the sky average of the angular diameter distance, and obtain the 95% limit |Δ DA/bar DA|lesssim 10-4. We consider the argument that areas of spherical surfaces are nearly unaffected by perturbations, which is often invoked in light propagation calculations. The closed case is consistent with this at 1σ, whereas in the open case the probability is only 1.4%.

  3. Measuring the speed of light with baryon acoustic oscillations.

    PubMed

    Salzano, Vincenzo; Dąbrowski, Mariusz P; Lazkoz, Ruth

    2015-03-13

    In this Letter, we describe a new method to use baryon acoustic oscillations (BAO) to derive a constraint on the possible variation of the speed of light. The method relies on the fact that there is a simple relation between the angular diameter distance (D(A)) maximum and the Hubble function (H) evaluated at the same maximum-condition redshift, which includes speed of light c. We note the close analogy of the BAO probe with a laboratory experiment: here we have D(A) which plays the role of a standard (cosmological) ruler, and H^{-1}, with the dimension of time, as a (cosmological) clock. We evaluate if current or future missions such as Euclid can be sensitive enough to detect any variation of c.

  4. Testing the Distance-Duality Relation in the Rh = ct Universe

    NASA Astrophysics Data System (ADS)

    Hu, J.; Wang, F. Y.

    2018-04-01

    In this paper, we test the cosmic distance duality (CDD) relation using the luminosity distances from joint light-curve analysis (JLA) type Ia supernovae (SNe Ia) sample and angular diameter distance sample from galaxy clusters. The Rh = ct and ΛCDM models are considered. In order to compare the two models, we constrain the CCD relation and the SNe Ia light-curve parameters simultaneously. Considering the effects of Hubble constant, we find that η ≡ DA(1 + z)2/DL = 1 is valid at the 2σ confidence level in both models with H0 = 67.8 ± 0.9 km/s/Mpc. However, the CDD relation is valid at 3σ confidence level with H0 = 73.45 ± 1.66 km/s/Mpc. Using the Akaike Information Criterion (AIC) and the Bayesian Information Criterion (BIC), we find that the ΛCDM model is very strongly preferred over the Rh = ct model with these data sets for the CDD relation test.

  5. Testing the distance-duality relation in the Rh = ct universe

    NASA Astrophysics Data System (ADS)

    Hu, J.; Wang, F. Y.

    2018-07-01

    In this paper, we test the cosmic distance-duality (CDD) relation using the luminosity distances from joint light-curve analysis Type Ia supernovae (SNe Ia) sample and angular diameter distance sample from galaxy clusters. The Rh = ct and Λ cold dark matter (CDM) models are considered. In order to compare the two models, we constrain the CDD relation and the SNe Ia light-curve parameters simultaneously. Considering the effects of Hubble constant, we find that η ≡ DA(1 + z)2/DL = 1 is valid at the 2σ confidence level in both models with H0= 67.8 ± 0.9 km -1s-1 Mpc. However, the CDD relation is valid at 3σ confidence level with H0= 73.45 ± 1.66 km -1s-1Mpc. Using the Akaike Information Criterion and the Bayesian Information Criterion, we find that the ΛCDM model is very stongly preferred over the Rh = ct model with these data sets for the CDD relation test.

  6. Dark Energy Survey Year 1 Results: Measurement of the Baryon Acoustic Oscillation scale in the distribution of galaxies to redshift 1

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbott, T.M.C.; et al.

    We present angular diameter distance measurements obtained by locating the BAO scale in the distribution of galaxies selected from the first year of Dark Energy Survey data. We consider a sample of over 1.3 million galaxies distributed over a footprint of 1318 degmore » $^2$ with $$0.6 < z_{\\rm photo} < 1$$ and a typical redshift uncertainty of $0.03(1+z)$. This sample was selected, as fully described in a companion paper, using a color/magnitude selection that optimizes trade-offs between number density and redshift uncertainty. We investigate the BAO signal in the projected clustering using three conventions, the angular separation, the co-moving transverse separation, and spherical harmonics. Further, we compare results obtained from template based and machine learning photometric redshift determinations. We use 1800 simulations that approximate our sample in order to produce covariance matrices and allow us to validate our distance scale measurement methodology. We measure the angular diameter distance, $$D_A$$, at the effective redshift of our sample divided by the true physical scale of the BAO feature, $$r_{\\rm d}$$. We obtain close to a 4 per cent distance measurement of $$D_A(z_{\\rm eff}=0.81)/r_{\\rm d} = 10.75\\pm 0.43 $$. These results are consistent with the flat $$\\Lambda$$CDM concordance cosmological model supported by numerous other recent experimental results.« less

  7. Transition from film to digital fundus photography in the Longitudinal Studies of the Ocular Complications of AIDS (LSOCA)

    PubMed Central

    Gangaputra, Sapna; Pak, Jeong Won; Peng, Qian; Hubbard, Larry D.; Thayer, Dennis; Krason, Zbigniew; Joyce, Jeff; Danis, Ronald P.

    2014-01-01

    Purpose To describe the transition to digital imaging and assess any impact on ocular disease classification. Methods Film and digital images, acquired by certified photographers, were evaluated independently according to standard procedures for the following: image quality, presence of cytomegalovirus (CMV) retinitis lesions, their extent, and proximity from disc and macula. Inter-grader agreement within the digital medium was also assessed. Results Among the fifteen eyes with CMV retinitis, the mean difference between film and digital images for linear distance of lesion edge to disc was 0.02 disc diameters (DD), for distance to center of macula was −0.04 DD and area covered by CMV retinitis was 0.95 disc area (DA). There was no statistically significant difference in distance and area measurements between media. Inter grader agreement in measurements of digital images was excellent for distance and area estimated. Conclusion Our results suggest that digital grading of CMV retinitis in LSOCA is comparable to that from film with respect to disease classification, measurements, and reproducibility. These findings provide support for continuity of grading data, despite the necessary transition in imaging media. PMID:21857393

  8. A 2 per cent distance to z = 0.35 by reconstructing baryon acoustic oscillations - I. Methods and application to the Sloan Digital Sky Survey

    NASA Astrophysics Data System (ADS)

    Padmanabhan, Nikhil; Xu, Xiaoying; Eisenstein, Daniel J.; Scalzo, Richard; Cuesta, Antonio J.; Mehta, Kushal T.; Kazin, Eyal

    2012-12-01

    We present the first application to density field reconstruction to a galaxy survey to undo the smoothing of the baryon acoustic oscillation (BAO) feature due to non-linear gravitational evolution and thereby improve the precision of the distance measurements possible. We apply the reconstruction technique to the clustering of galaxies from the Sloan Digital Sky Survey (SDSS) Data Release 7 (DR7) luminous red galaxy (LRG) sample, sharpening the BAO feature and achieving a 1.9 per cent measurement of the distance to z = 0.35. We update the reconstruction algorithm of Eisenstein et al. to account for the effects of survey geometry as well as redshift-space distortions and validate it on 160 LasDamas simulations. We demonstrate that reconstruction sharpens the BAO feature in the angle averaged galaxy correlation function, reducing the non-linear smoothing scale Σnl from 8.1 to 4.4 Mpc h-1. Reconstruction also significantly reduces the effects of redshift-space distortions at the BAO scale, isotropizing the correlation function. This sharpened BAO feature yields an unbiased distance estimate (<0.2 per cent) and reduces the scatter from 3.3 to 2.1 per cent. We demonstrate the robustness of these results to the various reconstruction parameters, including the smoothing scale, the galaxy bias and the linear growth rate. Applying this reconstruction algorithm to the SDSS LRG DR7 sample improves the significance of the BAO feature in these data from 3.3σ for the unreconstructed correlation function to 4.2σ after reconstruction. We estimate a relative distance scale DV/rs to z = 0.35 of 8.88 ± 0.17, where rs is the sound horizon and DV≡(DA2H-1)1/3 is a combination of the angular diameter distance DA and Hubble parameter H. Assuming a sound horizon of 154.25 Mpc, this translates into a distance measurement DV(z = 0.35) = 1.356 ± 0.025 Gpc. We find that reconstruction reduces the distance error in the DR7 sample from 3.5 to 1.9 per cent, equivalent to a survey with three times the volume of SDSS.

  9. Recruitments of trained citizen volunteering for conventional cardiopulmonary resuscitation are necessary to improve the outcome after out-of-hospital cardiac arrests in remote time-distance area: A nationwide population-based study.

    PubMed

    Takei, Yutaka; Kamikura, Takahisa; Nishi, Taiki; Maeda, Tetsuo; Sakagami, Satoru; Kubo, Minoru; Inaba, Hideo

    2016-08-01

    To compare the factors associated with survival after out-of-hospital cardiac arrests (OHCAs) among three time-distance areas (defined as interquartile range of time for emergency medical services response to patient's side). From a nationwide, prospectively collected data on 716,608 OHCAs between 2007 and 2012, this study analyzed 193,914 bystander-witnessed OHCAs without pre-hospital physician involvement. Overall neurologically favourable 1-month survival rates were 7.4%, 4.1% and 1.7% for close, intermediate and remote areas, respectively. We classified BCPR by type (compression-only vs. conventional) and by dispatcher-assisted CPR (DA-CPR) (with vs. without); the effects on time-distance area survival were analyzed by BCPR classification. Association of each BCPR classification with survival was affected by time-distance area and arrest aetiology (p<0.05). The survival rates in the remote area were much higher with conventional BCPR than with compression-only BCPR (odds ratio; 95% confidence interval, 1.26; 1.05-1.51) and with BCPR without DA-CPR than with BCPR with DA-CPR (1.54; 1.29-1.82). Accordingly, we classified BCPR into five groups (no BCPR, compression-only with DA-CPR, conventional with DA-CPR, compression-only without DA-CPR, and conventional without DA-CPR) and analyzed for associations with survival, both cardiac and non-cardiac related, in each time-distance area by multivariate logistic regression analysis. In the remote area, conventional BCPR without DA-CPR significantly improved survival after OHCAs of cardiac aetiology, compared with all the other BCPR groups. Other correctable factors associated with survival were short collapse-to-call and call-to-first CPR intervals. Every effort to recruit trained citizens initiating conventional BCPR should be made in remote time-distance areas. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  10. Tunneling Kinetics and Nonadiabatic Proton-Coupled Electron Transfer in Proteins: The Effect of Electric Fields and Anharmonic Donor-Acceptor Interactions.

    PubMed

    Salna, Bridget; Benabbas, Abdelkrim; Russo, Douglas; Champion, Paul M

    2017-07-20

    A proper description of proton donor-acceptor (D-A) distance fluctuations is crucial for understanding tunneling in proton-coupled electron transport (PCET). The typical harmonic approximation for the D-A potential results in a Gaussian probability distribution, which does not appropriately reflect the electronic repulsion forces that increase the energetic cost of sampling shorter D-A distances. Because these shorter distances are the primary channel for thermally activated tunneling, the analysis of tunneling kinetics depends sensitively on the inherently anharmonic nature of the D-A interaction. Thus, we have used quantum chemical calculations to account for the D-A interaction and developed an improved model for the analysis of experimental tunneling kinetics. Strong internal electric fields are also considered and found to contribute significantly to the compressive forces when the D-A distance distribution is positioned below the van der Waals contact distance. This model is applied to recent experiments on the wild type (WT) and a double mutant (DM) of soybean lipoxygenase-1 (SLO). The compressive force necessary to prepare the tunneling-active distribution in WT SLO is found to fall in the ∼ nN range, which greatly exceeds the measured values of molecular motor and protein unfolding forces. This indicates that ∼60-100 MV/cm electric fields, aligned along the D-A bond axis, must be generated by an enzyme conformational interconversion that facilitates the PCET tunneling reaction. Based on the absolute value of the measured tunneling rate, and using previously calculated values of the electronic matrix element, the population of this tunneling-active conformation is found to lie in the range 10 -5 -10 -7 , indicating this is a rare structural fluctuation that falls well below the detection threshold of recent ENDOR experiments. Additional analysis of the DM tunneling kinetics leads to a proposal that a disordered (high entropy) conformation could be tunneling-active due to its broad range of sampled D-A distances.

  11. Design, Modelling and Teleoperation of a 2 mm Diameter Compliant Instrument for the da Vinci Platform.

    PubMed

    Francis, P; Eastwood, K W; Bodani, V; Looi, T; Drake, J M

    2018-05-07

    This work explores the feasibility of creating and accurately controlling an instrument for robotic surgery with a 2 mm diameter and a three degree-of-freedom (DoF) wrist which is compatible with the da Vinci platform. The instrument's wrist is composed of a two DoF bending notched-nitinol tube pattern, for which a kinematic model has been developed. A base mechanism for controlling the wrist is designed for integration with the da Vinci Research Kit. A basic teleoperation task is successfully performed using two of the miniature instruments. The performance and accuracy of the instrument suggest that creating and accurately controlling a 2 mm diameter instrument is feasible and the design and modelling proposed in this work provide a basis for future miniature instrument development.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Buta, R.; de Vaucouleurs, G.

    The diameters d/sub r/ of inner ring structures in disk galaxies are used as geometric distance indicators to derive the distances of 453 spiral and lenticular galaxies, mainly in the distance interval 4<..delta..<63 Mpc. The diameters are weighted means from the catalogs to Kormendy, Pedreros and Madore, and the authors. The distances are calculated by means of the two- and three-parameter formulae of Paper II; the adopted mean distance moduli ..mu../sub 0/(r) have mean errors from all sources of 0.6--0.7 mag for the well-observed galaxies.

  13. 15 CFR 241.7 - Tolerances to be allowed.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... follows: Tolerance inches Diameter of head 1/4 Effective diameter of head 1/4 Distance between heads 1/4 Circumference of bulge, outside measurement 11/2 Length of stave 1/2 (1) If no dimension of a barrel of Class 1... the effective diameter of head and the distance between heads algebraically and multiply the result by...

  14. 15 CFR 241.7 - Tolerances to be allowed.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... follows: Tolerance inches Diameter of head 1/4 Effective diameter of head 1/4 Distance between heads 1/4 Circumference of bulge, outside measurement 11/2 Length of stave 1/2 (1) If no dimension of a barrel of Class 1... the effective diameter of head and the distance between heads algebraically and multiply the result by...

  15. 15 CFR 241.7 - Tolerances to be allowed.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... follows: Tolerance inches Diameter of head 1/4 Effective diameter of head 1/4 Distance between heads 1/4 Circumference of bulge, outside measurement 11/2 Length of stave 1/2 (1) If no dimension of a barrel of Class 1... the effective diameter of head and the distance between heads algebraically and multiply the result by...

  16. 15 CFR 241.7 - Tolerances to be allowed.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... follows: Tolerance inches Diameter of head 1/4 Effective diameter of head 1/4 Distance between heads 1/4 Circumference of bulge, outside measurement 11/2 Length of stave 1/2 (1) If no dimension of a barrel of Class 1... the effective diameter of head and the distance between heads algebraically and multiply the result by...

  17. Constraints on the Energy Density Content of the Universe Using Only Clusters of Galaxies

    NASA Technical Reports Server (NTRS)

    Molnar, Sandor M.; Haiman, Zoltan; Birkinshaw, Mark

    2003-01-01

    We demonstrate that it is possible to constrain the energy content of the Universe with high accuracy using observations of clusters of galaxies only. The degeneracies in the cosmological parameters are lifted by combining constraints from different observables of galaxy clusters. We show that constraints on cosmological parameters from galaxy cluster number counts as a function of redshift and accurate angular diameter distance measurements to clusters are complementary to each other and their combination can constrain the energy density content of the Universe well. The number counts can be obtained from X-ray and/or SZ (Sunyaev-Zeldovich effect) surveys, the angular diameter distances can be determined from deep observations of the intra-cluster gas using their thermal bremsstrahlung X-ray emission and the SZ effect (X-SZ method). In this letter we combine constraints from simulated cluster number counts expected from a 12 deg2 SZ cluster survey and constraints from simulated angular diameter distance measurements based on using the X-SZ method assuming an expected accuracy of 7% in the angular diameter distance determination of 70 clusters with redshifts less than 1.5. We find that R, can be determined within about 25%, A within 20%, and w within 16%. Any cluster survey can be used to select clusters for high accuracy distance measurements, but we assumed accurate angular diameter distance measurements for only 70 clusters since long observations are necessary to achieve high accuracy in distance measurements. Thus the question naturally arises: How to select clusters of galaxies for accurate diameter distance determinations? In this letter, as an example, we demonstrate that it is possible to optimize this selection changing the number of clusters observed, and the upper cut off of their redshift range. We show that constraints on cosmological parameters from combining cluster number counts and angular diameter distance measurements, as opposed to general expectations, will not improve substantially selecting clusters with redshifts higher than one. This important conclusion allow us to restrict our cluster sample to clusters closer than one, in a range where the observational time for accurate distance measurements are more manageable. Subject headings: cosmological parameters - cosmology: theory - galaxies: clusters: general - X-rays: galaxies: clusters

  18. The clustering of galaxies in the SDSS-III Baryon Oscillation Spectroscopic Survey: measuring H(z) and DA(z) at z = 0.57 with clustering wedges

    NASA Astrophysics Data System (ADS)

    Kazin, Eyal A.; Sánchez, Ariel G.; Cuesta, Antonio J.; Beutler, Florian; Chuang, Chia-Hsun; Eisenstein, Daniel J.; Manera, Marc; Padmanabhan, Nikhil; Percival, Will J.; Prada, Francisco; Ross, Ashley J.; Seo, Hee-Jong; Tinker, Jeremy; Tojeiro, Rita; Xu, Xiaoying; Brinkmann, J.; Joel, Brownstein; Nichol, Robert C.; Schlegel, David J.; Schneider, Donald P.; Thomas, Daniel

    2013-10-01

    We analyse the 2D correlation function of the Sloan Digital Sky Survey-III Baryon Oscillation Spectroscopic Survey (BOSS) CMASS sample of massive galaxies of the ninth data release to measure cosmic expansion H and the angular diameter distance DA at a mean redshift of = 0.57. We apply, for the first time, a new correlation function technique called clustering wedges ξΔμ(s). Using a physically motivated model, the anisotropic baryonic acoustic feature in the galaxy sample is detected at a significance level of 4.7σ compared to a featureless model. The baryonic acoustic feature is used to obtain model-independent constraints cz/H/rs = 12.28 ± 0.82 (6.7 percent accuracy) and DA/rs = 9.05 ± 0.27 (3.0 per cent) with a correlation coefficient of -0.5, where rs is the sound horizon scale at the end of the baryonic drag era. We conduct thorough tests on the data and 600 simulated realizations, finding robustness of the results regardless of the details of the analysis method. Combining this with rs constraints from the cosmic microwave background, we obtain H(0.57) = 90.8 ± 6.2 km s-1 Mpc-1 and DA(0.57) = 1386 ± 45 Mpc. We use simulations to forecast results of the final BOSS CMASS data set. We apply the reconstruction technique on the simulations demonstrating that the sharpening of the anisotropic baryonic acoustic feature should improve the detection as well as tighten constraints of H and DA by ˜30 per cent on average.

  19. Spatial Characteristics of Tree Diameter Distributions in a Temperate Old-Growth Forest

    PubMed Central

    Zhao, Xiuhai; von Gadow, Klaus

    2013-01-01

    This contribution identifies spatial characteristics of tree diameter in a temperate forest in north-eastern China, based on a fully censused observational study area covering 500×600 m. Mark correlation analysis with three null hypothesis models was used to determine departure from expectations at different neighborhood distances. Tree positions are clumped at all investigated scales in all 37 studied species, while the diameters of most species are spatially negatively correlated, especially at short distances. Interestingly, all three cases showing short-distance attraction of dbh marks are associated with light-demanding shrub species. The short-distance attraction of dbh marks indicates spatially aggregated cohorts of stems of similar size. The percentage of species showing significant dbh suppression peaked at a 4 m distance under the heterogeneous Poisson model. At scales exceeding the peak distance, the percentage of species showing significant dbh suppression decreases sharply with increasing distances. The evidence from this large observational study shows that some of the variation of the spatial characteristics of tree diameters is related variations of topography and soil chemistry. However, an obvious interpretation of this result is still lacking. Thus, removing competitors surrounding the target trees is an effective way to avoid neighboring competition effects reducing the growth of valuable target trees in forest management practice. PMID:23527066

  20. Spatial characteristics of tree diameter distributions in a temperate old-growth forest.

    PubMed

    Zhang, Chunyu; Wei, Yanbo; Zhao, Xiuhai; von Gadow, Klaus

    2013-01-01

    This contribution identifies spatial characteristics of tree diameter in a temperate forest in north-eastern China, based on a fully censused observational study area covering 500×600 m. Mark correlation analysis with three null hypothesis models was used to determine departure from expectations at different neighborhood distances. Tree positions are clumped at all investigated scales in all 37 studied species, while the diameters of most species are spatially negatively correlated, especially at short distances. Interestingly, all three cases showing short-distance attraction of dbh marks are associated with light-demanding shrub species. The short-distance attraction of dbh marks indicates spatially aggregated cohorts of stems of similar size. The percentage of species showing significant dbh suppression peaked at a 4 m distance under the heterogeneous Poisson model. At scales exceeding the peak distance, the percentage of species showing significant dbh suppression decreases sharply with increasing distances. The evidence from this large observational study shows that some of the variation of the spatial characteristics of tree diameters is related variations of topography and soil chemistry. However, an obvious interpretation of this result is still lacking. Thus, removing competitors surrounding the target trees is an effective way to avoid neighboring competition effects reducing the growth of valuable target trees in forest management practice.

  1. Pupil diameter, working distance and illumination during habitual tasks. Implications for simultaneous vision contact lenses for presbyopia.

    PubMed

    Cardona, Genís; López, Sílvia

    2016-01-01

    To determine working distance, pupil diameter and illumination in real life conditions in a sample of presbyopic participants performing habitual tasks. A total of 59 presbyopic subjects (aged between 45 and 63 years) with different occupational backgrounds participated in the study. Participants were first interviewed regarding their habitual tasks with the aid of an ad hoc questionnaire, following which in-office photopic and mesopic pupil diameter was determined. Pupil diameter was also evaluated while participants conducted each of the self-reported habitual tasks by taking a photograph, which was later submitted to image analysis. In addition, working distance was determined with a measuring tape and the illumination that reached the pupil during each of the different tasks was measured, in lux, with a light meter. The four most common habitual tasks were computer use, reading, sewing and sports. A high intersubject variability was found in pupil diameter, working distance and illumination conditions while conducting the same task. Statistically significant differences were found between the in-office measured photopic and mesopic pupil diameters and those obtained while participants were conducting their habitual tasks in real life conditions (all p<0.001). Potential multifocal contact lens users may present with different ages, different jobs or hobbies and different preferences regarding lighting conditions and working distances. This results in different pupil size, even within the same task. This information may be critical when selecting a particular lens design and add power. Eye care practitioners are therefore advised to assess pupil diameter in real life conditions. Copyright © 2015 Spanish General Council of Optometry. Published by Elsevier Espana. All rights reserved.

  2. 3D finite element modeling of epiretinal stimulation: Impact of prosthetic electrode size and distance from the retina.

    PubMed

    Sui, Xiaohong; Huang, Yu; Feng, Fuchen; Huang, Chenhui; Chan, Leanne Lai Hang; Wang, Guoxing

    2015-05-01

    A novel 3-dimensional (3D) finite element model was established to systematically investigate the impact of the diameter (Φ) of disc electrodes and the electrode-to-retina distance on the effectiveness of stimulation. The 3D finite element model was established based on a disc platinum stimulating electrode and a 6-layered retinal structure. The ground electrode was placed in the extraocular space in direct attachment with sclera and treated as a distant return electrode. An established criterion of electric-field strength of 1000 Vm-1 was adopted as the activation threshold for RGCs. The threshold current (TC) increased linearly with increasing Φ and electrode-to-retina distance and remained almost unchanged with further increases in diameter. However, the threshold charge density (TCD) increased dramatically with decreasing electrode diameter. TCD exceeded the electrode safety limit for an electrode diameter of 50 µm at an electrode-to-retina distance of 50 to 200 μm. The electric field distributions illustrated that smaller electrode diameters and shorter electrode-to-retina distances were preferred due to more localized excitation of RGC area under stimulation of different threshold currents in terms of varied electrode size and electrode-to-retina distances. Under the condition of same-amplitude current stimulation, a large electrode exhibited an improved potential spatial selectivity at large electrode-to-retina distances. Modeling results were consistent with those reported in animal electrophysiological experiments and clinical trials, validating the 3D finite element model of epiretinal stimulation. The computational model proved to be useful in optimizing the design of an epiretinal stimulating electrode for prosthesis.

  3. Impact of Chronic Rheumatic Valve Diseases on Large Vessels.

    PubMed

    Altunbas, Gokhan; Yuce, Murat; Ozer, Hasan O; Davutoglu, Vedat; Ercan, Suleyman; Kizilkan, Nese; Bilici, Muhammet

    2016-01-01

    BACKGROUND AND AIM OF STUDY: Rheumatic valvular heart disease, which remains a common health problem in developing countries, has numerous consequences on the heart chambers and circulation. The study aim was to investigate the effects of chronic rheumatic valve disease on the diameters of the descending aorta (DA) and inferior vena cava (IVC). METHODS: A total of 88 patients with echocardiographically documented rheumatic valvular heart disease and 112 healthy controls were enrolled into the study. All patients underwent detailed echocardiographic examinations, while their height and body weight were recorded and adjusted to their body surface area. RESULTS: The most common involvement was mitral valve disease, followed by aortic valve disease and tricuspid valve disease. The mean diameter of the DA (indexed to BSA) was 1.79 ± 0.49 cm for patients and 1.53 ± 0.41 for controls (p <0.001). The mean diameter of the IVC (indexed to BSA) was 1.69 ± 0.73 for patients and 1.38 ± 0.35 cm for controls (p <0.001). There was a significant positive correlation between mitral valve mean gradient and IVC diameter (p = 0.01, r = 0.18). There were also strong associations between the mitral valve area and the diameters of the DA (p = 0.001, r = -0.239) and IVC (p <0.001, r = -0.246). CONCLUSION: Rheumatic valve disease, especially mitral stenosis, was closely related to remodeling of the great vessels.

  4. Strong focusing effect of 660 nm laser by microsized tapered glass tubes with different diameters

    NASA Astrophysics Data System (ADS)

    Lin, Chongnan; Luo, Xujia; Zhu, Xiaoyang; Zhu, Li; Wang, Hongcheng; Zhang, Ao; Xu, Runyu; Qu, Zheng; Chen, Ximeng; Zhang, Weiyi; Shao, Jianxiong

    2017-09-01

    A laser with a wavelength of 660 nm was focused by microsized tapered glass tubes with different diameters of the exit. By using the 3-μm optical fiber and micrometer displacement stages, we measured the light intensity distribution around the focal spot, the focal distance, and the transmission coefficient of the light transmitted through these tubes. The focusing effect for the glass tubes with smaller outlet diameters of the exit was found to be much stronger than those with larger diameters of the exit. Furthermore, the dependence of the size and distance and the maximum intensity of the focal spot on the tubes' diameter of exit are obtained.

  5. Double diameter boring tool

    DOEpatents

    Ashbaugh, F.A.; Murry, K.R.

    1986-02-10

    A boring tool and a method of operation are provided for boring two concentric holes of precision diameters and depths in a single operation. The boring tool includes an elongated tool body, a shank for attachment to a standard adjustable boring head which is used on a manual or numerical control milling machine and first and second diametrically opposed cutting flutes formed for cutting in opposite directions. The diameter of the elongated tool body is substantially equal to the distance from the first flute tip to the axis of rotation plus the distance from the second flute tip to the axis of rotation. The axis of rotation of the tool is spaced from the tool centerline a distance substantially equal to one-half the distance from the second flute tip to the axis of rotation minus one-half the distance from the first flute tip to the axis of rotation. The method includes the step of inserting the boring tool into the boring head, adjusting the distance between the tool centerline and the tool axis of rotation as described above and boring the two concentric holes.

  6. Double diameter boring tool

    DOEpatents

    Ashbaugh, Fred N.; Murry, Kenneth R.

    1988-12-27

    A boring tool and a method of operation are provided for boring two concentric holes of precision diameters and depths in a single operation. The boring tool includes an elongated tool body, a shank for attachment to a standard adjustable boring head which is used on a manual or numerical control milling machine and first and second diametrically opposed cutting edges formed for cutting in opposite directions. The diameter of the elongated tool body is substantially equal to the distance from the first cutting edge tip to the axis of rotation plus the distance from the second cutting edge tip to the axis of rotation. The axis of rotation of the tool is spaced from the tool centerline a distance substantially equal to one-half the distance from the second cutting edge tip to the axis of rotation minus one-half the distance from the first cutting edge tip to the axis of rotation. The method includes the step of inserting the boring tool into the boring head, adjusting the distance between the tool centerline and the tool axis of rotation as described above and boring the two concentric holes.

  7. Double diameter boring tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashbaugh, F.A.; Murry, K.R.

    A boring tool and a method of operation are provided for boring two concentric holes of precision diameters and depths in a single operation. The boring tool includes an elongated tool body, a shank for attachment to a standard adjustable boring head which is used on a manual or numerical control milling machine and first and second diametrically opposed cutting flutes formed for cutting in opposite directions. The diameter of the elongated tool body is substantially equal to the distance from the first flute tip to the axis of rotation plus the distance from the second flute tip to themore » axis of rotation. The axis of rotation of the tool is spaced from the tool centerline a distance substantially equal to one-half the distance from the second flute tip to the axis of rotation minus one-half the distance from the first flute tip to the axis of rotation. The method includes the step of inserting the boring tool into the boring head, adjusting the distance between the tool centerline and the tool axis of rotation as described above and boring the two concentric holes.« less

  8. New Members in the Galaxy Group Around Giant Radio Galaxy DA 240

    NASA Astrophysics Data System (ADS)

    Chen, Ru-Rong; Peng, Bo; Strom, Richard

    2018-05-01

    With new spectroscopic observations of group candidates around the giant radio galaxy DA 240, we have identified five new group members, increasing the number to twenty-five. While all the new members are located some distance from the host galaxy, two of them lie in one of the radio lobes, and the rest are found at a distance from the radio components. The new group members reinforce our earlier conclusion that the distribution of the DA 240 group with respect to the radio lobes is unusual among giant radio galaxy host environments.

  9. Changing the Diameter of a Viewing Tube

    ERIC Educational Resources Information Center

    Obara, Samuel

    2009-01-01

    This article is about the students' investigation about the relationship between the diameter of the view tubes (x) of constant lengths and the viewable vertical distance (y) on the wall while keeping the perpendicular distance from the eyeball to the wall constant. The students collected data and used and represented it in tabular and graphical…

  10. A study on a dental device for the prevention of mucosal dose enhancement caused by backscatter radiation from dental alloy during external beam radiotherapy.

    PubMed

    Katsura, Kouji; Utsunomiya, Satoru; Abe, Eisuke; Sakai, Hironori; Kushima, Naotaka; Tanabe, Satoshi; Yamada, Takumi; Hayakawa, Takahide; Yamanoi, Yoshihiko; Kimura, Syuhei; Wada, Shinichi; Aoyama, Hidefumi; Hayashi, Takafumi

    2016-11-01

    The changes in dose distribution caused by backscatter radiation from a common commercial dental alloy (Au-Ag-Pd dental alloy; DA) were investigated to identify the optimal material and thicknesses of a dental device (DD) for effective prevention of mucositis. To this end, 1 cm 3 of DA was irradiated with a 6-MV X-ray beam (100 MU) in a field size of 10 × 10 cm 2 using a Novalis TX linear accelerator. Ethylene vinyl acetate copolymer, polyolefin elastomer, and polyethylene terephthalate (PET) were selected as DD materials. The depth dose along the central axis was determined with respect to the presence/absence of DA and DDs at thicknesses of 1-10 mm using a parallel-plate ionization chamber. The dose in the absence of DDs showed the lowest value at a distance of 5 mm from the DA surface and gradually increased with distance between the measurement point and the DA surface for distances of ≥5 mm. Except for PET, no significant difference between the DA dose curves for the presence and absence of DDs was observed. In the dose curve, PET showed a slightly higher dose for DA with DD than for DA without DD for thicknesses of ≥4 mm. The findings herein suggest that the optimal DD material for preventing local dose enhancement of the mucosa caused by DA backscatter radiation should have a relatively low atomic number and physical density and that optimal DD thickness should be chosen considering backscatter radiation and percentage depth dose. © The Author 2016. Published by Oxford University Press on behalf of The Japan Radiation Research Society and Japanese Society for Radiation Oncology.

  11. Diameters of the cavo-sinus-tricuspid area in relation to type I atrial flutter.

    PubMed

    Kozłowski, Dariusz; Hreczecha, Jolanta; Skwarek, Magdalena; Piwko, Grzegorz; Kosiński, Adam; Gawrysiak, Marcin; Grzybiak, Marek

    2003-05-01

    Cardiac arrhythmias have troubled patients and fascinated physicians for centuries. The twentieth century was an era of progress, when the mechanism of cardiac disorders became more commonly recognised. Arrhythmias may be due to abnormalities of automaticity, to abnormalities of conduction, or to a combination of both. In order for re-entry to occur, an area of slowing conduction combined with unidirectional block must be present. Much investigation has centred on the underlying re-entry mechanisms of atrial flutter. In the light of these facts, it would seem that a close acquaintance with the detailed topography of the vena cava orifice (cavo), coronary sinus orifice (sinus) and the attachment of the septal leaflet of the tricuspid valve (tricupid) area could be of great interest, especially for invasive cardiologists. The research was conducted carried out on material consisting of 41 hearts of humans of both sexes from the age of 12 to 80 (6 female, 35 male). Classical macroscopic methods of anatomical evaluation were used. The following measurements were made: the shortest distance between the Eustachian valve and the attachment of the tricuspid valve on the left margin of the coronary sinus orifice (diameter 1), the distance between the attachment of the tricuspid valve and the inferior margin of the sinus orifice (diameter 2), the distance between the Eustachian valve and the attachment of the tricuspid valve on the right margin of the coronary sinus orifice (diameter 3), the distance between the inferior margin of the vena cava inferior and the attachment of the tricuspid valve (diameter 4) and, finally, the diameter between the attachment of the septal cusp of the tricuspid valve and the extemal border of the vena cava inferior (diameter 5). No correlation was found between the age and sex of the three groups of the material. The dimensions of the structure examined were similar in the three groups of hearts. In young adult hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.02 mm (diameter 1), 8.97 mm (diameter 2), 17.27 mm (diameter 3), 26.87 mm (diameter 4), 36.42 mm (diameter 5). In the mature adult hearts all the diameters measured ranged from 8 to 45 mm; 18.19 mm (diameter 1), 10.54 mm (diameter 2), 19.95 mm (diameter 3), 28.90 mm (diameter 4), 39.63 mm (diameter 5). In the older adults hearts all the diameters measured ranged from 4 to 47 mm. The average diameters were, respectively: 15.65 mm (diameter 1), 8.70 mm (diameter 2), 7.25 mm (diameter 3), 26.80 mm (diameter 4), 35.85 mm (diameter 5). On the basis of our study we were able to conclude that the diameters of the cavo-sinus-tricuspid area were constant and did not differ significantly within the three (young, mature, old) adult groups examined.

  12. Decreased Lamina Cribrosa Beam Thickness and Pore Diameter Relative to Distance From the Central Retinal Vessel Trunk

    PubMed Central

    Wang, Bo; Lucy, Katie A.; Schuman, Joel S.; Sigal, Ian A.; Bilonick, Richard A.; Kagemann, Larry; Kostanyan, Tigran; Lu, Chen; Liu, Jonathan; Grulkowski, Ireneusz; Fujimoto, James G.; Ishikawa, Hiroshi; Wollstein, Gadi

    2016-01-01

    Purpose To investigate how the lamina cribrosa (LC) microstructure changes with distance from the central retinal vessel trunk (CRVT), and to determine how this change differs in glaucoma. Methods One hundred nineteen eyes (40 healthy, 29 glaucoma suspect, and 50 glaucoma) of 105 subjects were imaged using swept-source optical coherence tomography (OCT). The CRVT was manually delineated at the level of the anterior LC surface. A line was fit to the distribution of LC microstructural parameters and distance from CRVT to measure the gradient (change in LC microstructure per distance from the CRVT) and intercept (LC microstructure near the CRVT). A linear mixed-effects model was used to determine the effect of diagnosis on the gradient and intercept of the LC microstructure with distance from the CRVT. A Kolmogorov-Smirnov test was applied to determine the difference in distribution between the diagnostic categories. Results The percent of visible LC in all scans was 26 ± 7%. Beam thickness and pore diameter decreased with distance from the CRVT. Glaucoma eyes had a larger decrease in beam thickness (−1.132 ± 0.503 μm, P = 0.028) and pore diameter (−0.913 ± 0.259 μm, P = 0.001) compared with healthy controls per 100 μm from the CRVT. Glaucoma eyes showed increased variability in both beam thickness and pore diameter relative to the distance from the CRVT compared with healthy eyes (P < 0.05). Conclusions These findings results demonstrate the importance of considering the anatomical location of CRVT in the assessment of the LC, as there is a relationship between the distance from the CRVT and the LC microstructure, which differs between healthy and glaucoma eyes. PMID:27286366

  13. Cosmic equation of state from combined angular diameter distances: Does the tension with luminosity distances exist?

    NASA Astrophysics Data System (ADS)

    Cao, Shuo; Zhu, Zong-Hong

    2014-10-01

    Using relatively complete observational data concerning four angular diameter distance (ADD) measurements and combined SN +GRB observations representing current luminosity distance (LD) data, this paper investigates the compatibility of these two cosmological distances considering three classes of dark energy equation of state (EoS) reconstruction. In particular, we use strongly gravitationally lensed systems from various large systematic gravitational lens surveys and galaxy clusters, which yield the Hubble constant independent ratio between two angular diameter distances Dl s/Ds data. Our results demonstrate that, with more general categories of standard ruler data, ADD and LD data are compatible at 1 σ level. Second, we note that consistency between ADD and LD data is maintained irrespective of the EoS parametrizations: there is a good match between the universally explored Chevalier-Polarski-Linder model and other formulations of cosmic equation of state. Especially for the truncated generalized equation of state (GEoS) model with β =-2 , the conclusions obtained with ADD and LD are almost the same. Finally, statistical analysis of generalized dark energy equation of state performed on four classes of ADD data provides stringent constraints on the EoS parameters w0 , wβ, and β , which suggest that dark energy was a subdominant component at early times. Moreover, the GEoS parametrization with β ≃1 seems to be a more favorable two-parameter model to characterize the cosmic equation of state, because the combined angular diameter distance data (SGL +CBF +BAO +WMAP 9 ) provide the best-fit value β =0.75 1-0.480+0.465 .

  14. Phased Array Focusing for Acoustic Wireless Power Transfer.

    PubMed

    Tseng, Victor Farm-Guoo; Bedair, Sarah S; Lazarus, Nathan

    2018-01-01

    Wireless power transfer (WPT) through acoustic waves can achieve higher efficiencies than inductive coupling when the distance is above several times the transducer size. This paper demonstrates the use of ultrasonic phased arrays to focus power to receivers at arbitrary locations to increase the power transfer efficiency. Using a phased array consisting of 37 elements at a distance nearly 5 times the receiver transducer diameter, a factor of 2.6 increase in efficiency was achieved when compared to a case equivalent to a single large transducer with the same peak efficiency distance. The array has a total diameter of 7 cm, and transmits through air at 40 kHz to a 1.1-cm diameter receiver, achieving a peak overall efficiency of 4% at a distance of 5 cm. By adjusting the focal distance, the efficiency can also be maintained relatively constant at distances up to 9 cm. Numerical models were developed and shown to closely match the experimental energy transfer behavior; modeling results indicate that the efficiency can be further doubled by increasing the number of elements. For comparison, an inductive WPT system was also built with the diameters of the transmitting and receiving coils equivalent to the dimensions of the transmitting ultrasonic phased array and receiver transducer, and the acoustic WPT system achieved higher efficiencies than the inductive WPT system when the transmit-to-receive distance is above 5 cm. In addition, beam angle steering was demonstrated by using a simplified seven-element 1-D array, achieving power transfer less dependent on receiver placement.

  15. The clustering of galaxies in the completed SDSS-III Baryon Oscillation Spectroscopic Survey: Single-probe measurements from DR12 galaxy clustering – towards an accurate model

    DOE PAGES

    Chia -Hsun Chuang; Pellejero-Ibanez, Marco; Rodriguez-Torres, Sergio; ...

    2016-06-26

    We analyze the broad-range shape of the monopole and quadrupole correlation functions of the BOSS Data Release 12 (DR12) CMASS and LOWZ galaxy sample to obtain constraints on the Hubble expansion rate H(z), the angular-diameter distance DA(z), the normalised growth rate f(z)σ 8(z), and the physical matter density Ω mh 2. In addition, we adopt wide and flat priors on all model parameters in order to ensure the results are those of a `single-probe' galaxy clustering analysis. We also marginalize over three nuisance terms that account for potential observational systematics affecting the measured monopole. However, such Monte Carlo Markov Chainmore » analysis is computationally expensive for advanced theoretical models, thus we develop a new methodology to speed up our analysis.« less

  16. Variability of Origin of Splanchnic and Renal Vessels From the Thoracoabdominal Aorta.

    PubMed

    Mazzaccaro, D; Malacrida, G; Nano, G

    2015-01-01

    To analyze the variability of origin of the celiac trunk (CT), the superior mesenteric artery (SMA), the right renal artery (RRA), and the left renal artery (LRA) in terms of mutual distances, angle from the sagittal aortic axis (clock position), and ostial diameters on computed tomography angiographies (CTAs) in three groups of patients. One hundred and fifty CTAs of 50 patients with a non-dilated thoracoabdominal aorta (group A), 50 with thoracoabdominal aneurysm (B), and 50 with infrarenal aneurysm (C) were reviewed. The measurements performed on CTAs, as well as the patients' age, sex, and body surface area, were analyzed. p values <.05 were considered statistically significant. The clock position of the CT and the SMA, the diameters of all vessels, and the distance of the CTeSMA followed a Gaussian distribution. In contrast, the clock position of the renal vessels did not follow a normal distribution, and nor did the distances of the SMA-RRA, SMA-LRA, RRA-LRA or the distances between the renal arteries and the aortic bifurcation. The same values did not differ significantly among the three groups, with the exception of the distances between the renal arteries and the aortic bifurcation, significantly greater in group C. The clock position of the LRA and the distances of the SMA-LRA, SMA-RRA, RRA-LRA and between both renal arteries and the aortic bifurcation showed a significant correlation with the increase of aortic diameter. The anatomic variability of the origin of both the CT and the SMA in terms of clock position and mutual distances followed a Gaussian distribution, regardless of group. The same applies to the ostial diameters of renal and visceral vessels. In contrast, the origin of the renal vessels had a statistically significant heterogeneity that seemed to be correlated with the increase of aortic diameter in the mesenteric and renal aortic region.

  17. Residential distance to major roadways and cardiac structure in African Americans: cross-sectional results from the Jackson Heart Study.

    PubMed

    Weaver, Anne M; Wellenius, Gregory A; Wu, Wen-Chih; Hickson, DeMarc A; Kamalesh, Masoor; Wang, Yi

    2017-03-08

    Heart failure (HF) is a significant source of morbidity and mortality among African Americans. Ambient air pollution, including from traffic, is associated with HF, but the mechanisms remain unknown. The objectives of this study were to estimate the cross-sectional associations between residential distance to major roadways with markers of cardiac structure: left ventricular (LV) mass index, LV end-diastolic diameter, LV end-systolic diameter, and LV hypertrophy among African Americans. We studied baseline participants of the Jackson Heart Study (recruited 2000-2004), a prospective cohort of cardiovascular disease (CVD) among African Americans living in Jackson, Mississippi, USA. All cardiac measures were assessed from echocardiograms. We assessed the associations between residential distance to roads and cardiac structure indicators using multivariable linear regression or multivariable logistic regression, adjusting for potential confounders. Among 4826 participants, residential distance to road was <150 m for 103 participants, 150-299 m for 158, 300-999 for 1156, and ≥1000 m for 3409. Those who lived <150 m from a major road had mean 1.2 mm (95% CI 0.2, 2.1) greater LV diameter at end-systole compared to those who lived ≥1000 m. We did not observe statistically significant associations between distance to roads and LV mass index, LV end-diastolic diameter, or LV hypertrophy. Results did not materially change after additional adjustment for hypertension and diabetes or exclusion of those with CVD at baseline; results strengthened when modeling distance to A1 roads (such as interstate highways) as the exposure of interest. We found that residential distance to roads may be associated with LV end-systolic diameter, a marker of systolic dysfunction, in this cohort of African Americans, suggesting a potential mechanism by which exposure to traffic pollution increases the risk of HF.

  18. Predicted accommodative response from image quality in young eyes fitted with different dual-focus designs.

    PubMed

    Faria-Ribeiro, Miguel; Amorim-de-Sousa, Ana; González-Méijome, José M

    2018-05-01

    To investigate the separated and combined influences of inner zone (IZ) diameter and effective add power of dual-focus contact lenses (CL) in the image quality at distance and near viewing, in a functional accommodating model eye. Computational wave-optics methods were used to define zonal bifocal pupil functions, representing the optic zones of nine dual-focus centre-distance CLs. The dual-focus pupil functions were defined having IZ diameters of 2.10 mm, 3.36 mm and 4.00 mm, with add powers of 1.5 D, 2.0 D and 2.5 D (dioptres), for each design, that resulted in a ratio of 64%/36% between the distance and treatment zone areas, bounded by a 6 mm entrance pupil. A through-focus routine was implemented in MATLAB to simulate the changes in image quality, calculated from the Visual Strehl ratio, as the eye with the dual-focus accommodates, from 0 to -3.00 D target vergences. Accommodative responses were defined as the changes in the defocus coefficient, combined with a change in fourth and sixth order spherical aberration, which produced a peak in image quality at each target vergence. Distance viewing image quality was marginally affected by IZ diameter but not by add power. Near image quality obtained when focussing the image formed by the near optics was only higher by a small amount compared to the other two IZ diameters. The mean ± standard deviation values obtained with the three adds were 0.28 ± 0.02, 0.23 ± 0.02 and 0.22 ± 0.02, for the small, medium and larger IZ diameters, respectively. On the other hand, near image quality predicted by focussing the image formed by the distance optics was considerably lower relatively to the other two IZ diameters. The mean ± standard deviation values obtained with the three adds were 0.15 ± 0.01, 0.38 ± 0.00 and 0.54 ± 0.01, for the small, medium and larger IZ diameters, respectively. During near viewing through dual-focus CLs, image quality depends on the diameter of the most inner zone of the CL, while add power only affects the range of clear focus when focussing the image formed by the CL near optics. When only image quality gain is taken into consideration, medium and large IZ diameters designs are most likely to promote normal accommodative responses driven by the CL distance optics, while a smaller IZ diameter design is most likely to promote a reduced accommodative response driven by the dual-focus CL near optics. © 2018 The Authors Ophthalmic & Physiological Optics © 2018 The College of Optometrists.

  19. Autocorrelation descriptor improvements for QSAR: 2DA_Sign and 3DA_Sign

    NASA Astrophysics Data System (ADS)

    Sliwoski, Gregory; Mendenhall, Jeffrey; Meiler, Jens

    2016-03-01

    Quantitative structure-activity relationship (QSAR) is a branch of computer aided drug discovery that relates chemical structures to biological activity. Two well established and related QSAR descriptors are two- and three-dimensional autocorrelation (2DA and 3DA). These descriptors encode the relative position of atoms or atom properties by calculating the separation between atom pairs in terms of number of bonds (2DA) or Euclidean distance (3DA). The sums of all values computed for a given small molecule are collected in a histogram. Atom properties can be added with a coefficient that is the product of atom properties for each pair. This procedure can lead to information loss when signed atom properties are considered such as partial charge. For example, the product of two positive charges is indistinguishable from the product of two equivalent negative charges. In this paper, we present variations of 2DA and 3DA called 2DA_Sign and 3DA_Sign that avoid information loss by splitting unique sign pairs into individual histograms. We evaluate these variations with models trained on nine datasets spanning a range of drug target classes. Both 2DA_Sign and 3DA_Sign significantly increase model performance across all datasets when compared with traditional 2DA and 3DA. Lastly, we find that limiting 3DA_Sign to maximum atom pair distances of 6 Å instead of 12 Å further increases model performance, suggesting that conformational flexibility may hinder performance with longer 3DA descriptors. Consistent with this finding, limiting the number of bonds in 2DA_Sign from 11 to 5 fails to improve performance.

  20. Infraorbital foramen: horizontal location in relation to ala nasi.

    PubMed

    Takahashi, Yasuhiro; Kakizaki, Hirohiko; Nakano, Takashi

    2011-01-01

    To examine the horizontal location of the infraorbital foramen in relation to the ala nasi. Fifty-six orbits of 28 Japanese cadavers (18 male and 10 female cadavers; average death age, 79.7 years), fixed in 10% buffered formalin, were used. The horizontal distance from the vertical line through the lateral margin of the ala nasi to the medial margin of the infraorbital foramen (the horizontal distance) and the transverse diameter of the infraorbital foramen (the transverse diameter) were examined. Values were compared between genders and sides using Student's t test. The mean horizontal distance was 4.9 mm, with no significant difference between genders (male, 5.2 mm; female, 4.4 mm; p = 0.150) or sides (right, 4.9 mm; left, 4.9 mm; p = 0.944). The mean transverse diameter was 5.5 mm. Although there was no significant difference in this diameter between sides (right, 5.3 mm; left, 5.6 mm; p = 0.358), there was a significant difference between genders (male, 5.7 mm; female, 5.1 mm; p = 0.033). The horizontal distance had no gender difference. This value is available irrespective of gender in surgery.

  1. Interruption of Hydrogen Bonding Networks of Water in Carbon Nanotubes Due to Strong Hydration Shell Formation.

    PubMed

    Oya, Yoshifumi; Hata, Kenji; Ohba, Tomonori

    2017-10-24

    We present the structures of NaCl aqueous solution in carbon nanotubes with diameters of 1, 2, and 3 nm based on an analysis performed using X-ray diffraction and canonical ensemble Monte Carlo simulations. Anomalously longer nearest-neighbor distances were observed in the electrolyte for the 1-nm-diameter carbon nanotubes; in contrast, in the 2 and 3 nm carbon nanotubes, the nearest-neighbor distances were shorter than those in the bulk electrolyte. We also observed similar properties for water in carbon nanotubes, which was expected because the main component of the electrolyte was water. However, the nearest-neighbor distances of the electrolyte were longer than those of water in all of the carbon nanotubes; the difference was especially pronounced in the 2-nm-diameter carbon nanotubes. Thus, small numbers of ions affected the entire structure of the electrolyte in the nanopores of the carbon nanotubes. The formation of strong hydration shells between ions and water molecules considerably interrupted the hydrogen bonding between water molecules in the nanopores of the carbon nanotubes. The hydration shell had a diameter of approximately 1 nm, and hydration shells were thus adopted for the nanopores of the 2-nm-diameter carbon nanotubes, providing an explanation for the large difference in the nearest-neighbor distances between the electrolyte and water in these nanopores.

  2. Mobile Distance Learning with PDAs: Development and Testing of Pedagogical and System Solutions Supporting Mobile Distance Learners

    ERIC Educational Resources Information Center

    Rekkedal, Torstein; Dye, Aleksander

    2007-01-01

    The article discusses basic teaching-learning philosophies and experiences from the development and testing of mobile learning integrated with the online distance education system at NKI (Norwegian Knowledge Institute) Distance Education. The article builds on experiences from three European Union (EU) supported "Leonardo da Vinci"…

  3. A Novel Decision Aid to Support Informed Decision-Making Process in Patients with a Symptomatic Nonlower Pole Renal Stone <20 mm in Diameter.

    PubMed

    Gökce, Mehmet İlker; Esen, Barış; Sancı, Adem; Akpınar, Cağrı; Süer, Evren; Gülpınar, Ömer

    2017-07-01

    Stone disease is an important health problem, and patients have different treatment choices. Shared decision making is recommended for deciding the treatment type, but patient education is necessary. Decision aids (DAs) are used for this aim, and herein, we developed a novel DA for patients with symptomatic nonlower pole renal stones <20 mm in diameter. The DA development process was established based on the recommended guides. General characteristics of the stone disease and details of the shockwave lithotripsy and retrograde intrarenal surgery were included in the content of the DA. The DA was further revised based on the suggestions of different physician groups and patients. The DA was evaluated by three physicians (Delphi assessment-International Patient Decision Aid Standards [IPDAS] Collaboration standards) and 25 patients (questionnaire of six questions with five-point Likert scale). The DA was designed as a booklet, and Delphi group assessment resulted in a total score of 50/54. Patient evaluation of the DA resulted in favorable outcomes, and patients generally recommended its use by other patients. This novel DA for patients with a symptomatic nonlower pole renal stone <20 mm showed promising results and was well accepted by the patients. We believe that this DA will have a positive impact on patients' level of knowledge. Increased level of knowledge will also improve the patients' contribution to the shared decision-making process. A further prospective randomized trial to compare with the standard patient informing process is also planned.

  4. Spin-tunnel investigation of the spinning characteristics of typical single-engine general aviation airplane designs. 2: Low-wing model A; tail parachute diameter and canopy distance for emergency spin recovery

    NASA Technical Reports Server (NTRS)

    Burk, S. M., Jr.; Bowman, J. S., Jr.; White, W. L.

    1977-01-01

    A spin tunnel study is reported on a scale model of a research airplane typical of low-wing, single-engine, light general aviation airplanes to determine the tail parachute diameter and canopy distance (riser length plus suspension-line length) required for energency spin recovery. Nine tail configurations were tested, resulting in a wide range of developed spin conditions, including steep spins and flat spins. The results indicate that the full-scale parachute diameter required for satisfactory recovery from the most critical conditions investigated is about 3.2 m and that the canopy distance, which was found to be critical for flat spins, should be between 4.6 and 6.1 m.

  5. The globe and orbit in Laron syndrome.

    PubMed

    Kornreich, L; Konen, O; Lilos, P; Laron, Z

    2011-09-01

    Patients with LS have an inborn growth hormone resistance, resulting in failure to generate IGF-1. The purpose of this study was to evaluate the size of the eye and orbit in LS. We retrospectively reviewed the MR imaging of the brain in 9 patients with LS for the following parameters: axial diameter of the globe, interzygomatic distance, perpendicular distance from the interzygomatic line to margins of the globe, medial-to-lateral diameter of the orbit at the anterior orbital rim, distance from the anterior orbital rim to the anterior globe, maximal distance between the medial walls of the orbits, lateral orbital wall angle, lateral orbital wall length, and mediolateral thickness of the intraorbital fat in the most cranial image of the orbit. All measurements were made bilaterally. Twenty patients referred for MR imaging for unrelated reasons served as control subjects. Compared with the control group, the patients with LS had a significantly smaller maximal globe diameter and shallower but wider orbits due to a shorter lateral wall, a smaller medial distance between the orbits, and a larger angle of the orbit. The ratio between the most anterior orbital diameter and the globe was greater than that in controls. The position of the globe was more anterior in relation to the interzygomatic line. Shallow and wide orbits and small globes relative to orbital size are seen in LS and may be secondary to IGF-1 deficiency.

  6. Combining Graphical and Analytical Methods with Molecular Simulations To Analyze Time-Resolved FRET Measurements of Labeled Macromolecules Accurately

    PubMed Central

    2017-01-01

    Förster resonance energy transfer (FRET) measurements from a donor, D, to an acceptor, A, fluorophore are frequently used in vitro and in live cells to reveal information on the structure and dynamics of DA labeled macromolecules. Accurate descriptions of FRET measurements by molecular models are complicated because the fluorophores are usually coupled to the macromolecule via flexible long linkers allowing for diffusional exchange between multiple states with different fluorescence properties caused by distinct environmental quenching, dye mobilities, and variable DA distances. It is often assumed for the analysis of fluorescence intensity decays that DA distances and D quenching are uncorrelated (homogeneous quenching by FRET) and that the exchange between distinct fluorophore states is slow (quasistatic). This allows us to introduce the FRET-induced donor decay, εD(t), a function solely depending on the species fraction distribution of the rate constants of energy transfer by FRET, for a convenient joint analysis of fluorescence decays of FRET and reference samples by integrated graphical and analytical procedures. Additionally, we developed a simulation toolkit to model dye diffusion, fluorescence quenching by the protein surface, and FRET. A benchmark study with simulated fluorescence decays of 500 protein structures demonstrates that the quasistatic homogeneous model works very well and recovers for single conformations the average DA distances with an accuracy of < 2%. For more complex cases, where proteins adopt multiple conformations with significantly different dye environments (heterogeneous case), we introduce a general analysis framework and evaluate its power in resolving heterogeneities in DA distances. The developed fast simulation methods, relying on Brownian dynamics of a coarse-grained dye in its sterically accessible volume, allow us to incorporate structural information in the decay analysis for heterogeneous cases by relating dye states with protein conformations to pave the way for fluorescence and FRET-based dynamic structural biology. Finally, we present theories and simulations to assess the accuracy and precision of steady-state and time-resolved FRET measurements in resolving DA distances on the single-molecule and ensemble level and provide a rigorous framework for estimating approximation, systematic, and statistical errors. PMID:28709377

  7. Identification of a Common R-Chondrite Impactor on the Ureilite Parent Body

    NASA Technical Reports Server (NTRS)

    Downes, H.; Mittlefehldt, D. W.

    2006-01-01

    Polymict ureilites are brecciated ultramafic meteorites that contain a variety of single mineral and lithic clasts. They represent the surface debris from a small, differentiated asteroid. We are continuing a detailed petrological study of several polymict ureilites including EET 87720, EET 83309 and FRO93008 (from Antarctica), North Haig, Nilpena (Australia), DaG 976, DaG 999, DaG 1000 and DaG 1023 (Libya). The latter four stones are probably paired. Clast sizes can be 10 mm in diameter, so a thin-section can consist of a single lithic clast.

  8. Probability of Damage to Sidewalks and Curbs by Street Trees in the Tropics

    Treesearch

    John K. Francis; Bernard R. Parresol; Juana Marin de Patino

    1996-01-01

    For 75 trees each of 12 species growing along streets in San Juan, Puerto Rico and Merida, Mexico, diameter at breast height and distance to sidewalk or curb was measured and damage (cracking or raising) was evaluated. Logistic analysis was used to construct a model to predict probability of damage to sidewalk or curb. Distance to the pavement, diameter of the tree,...

  9. Comparison of efficiency of distance measurement methodologies in mango (Mangifera indica) progenies based on physicochemical descriptors.

    PubMed

    Alves, E O S; Cerqueira-Silva, C B M; Souza, A M; Santos, C A F; Lima Neto, F P; Corrêa, R X

    2012-03-14

    We investigated seven distance measures in a set of observations of physicochemical variables of mango (Mangifera indica) submitted to multivariate analyses (distance, projection and grouping). To estimate the distance measurements, five mango progeny (total of 25 genotypes) were analyzed, using six fruit physicochemical descriptors (fruit weight, equatorial diameter, longitudinal diameter, total soluble solids in °Brix, total titratable acidity, and pH). The distance measurements were compared by the Spearman correlation test, projection in two-dimensional space and grouping efficiency. The Spearman correlation coefficients between the seven distance measurements were, except for the Mahalanobis' generalized distance (0.41 ≤ rs ≤ 0.63), high and significant (rs ≥ 0.91; P < 0.001). Regardless of the origin of the distance matrix, the unweighted pair group method with arithmetic mean grouping method proved to be the most adequate. The various distance measurements and grouping methods gave different values for distortion (-116.5 ≤ D ≤ 74.5), cophenetic correlation (0.26 ≤ rc ≤ 0.76) and stress (-1.9 ≤ S ≤ 58.9). Choice of distance measurement and analysis methods influence the.

  10. Constraints on the Energy Content of the Universe from a Combination of Galaxy Cluster Observables

    NASA Technical Reports Server (NTRS)

    Molnar, Sandor M.; Haiman, Zoltan; Birkinshaw, Mark; Mushotzky, Richard F.

    2003-01-01

    We demonstrate that constraints on cosmological parameters from the distribution of clusters as a function of redshift (dN/dz) are complementary to accurate angular diameter distance (D(sub A)) measurements to clusters, and their combination significantly tightens constraints on the energy density content of the Universe. The number counts can be obtained from X-ray and/or SZ (Sunyaev-Ze'dovich effect) surveys, and the angular diameter distances can be determined from deep observations of the intra-cluster gas using their thermal bremsstrahlung X-ray emission and the SZ effect. We combine constraints from simulated cluster number counts expected from a 12 deg(sup 2) SZ cluster survey and constraints from simulated angular diameter distance measurements based on the X-ray/SZ method assuming a statistical accuracy of 10% in the angular diameter distance determination of 100 clusters with redshifts less than 1.5. We find that Omega(sub m), can be determined within about 25%, Omega(sub lambda) within 20% and w within 16%. We show that combined dN/dz+(sub lambda) constraints can be used to constrain the different energy densities in the Universe even in the presence of a few percent redshift dependent systematic error in D(sub lambda). We also address the question of how best to select clusters of galaxies for accurate diameter distance determinations. We show that the joint dN/dz+ D(lambda) constraints on cosmological parameters for a fixed target accuracy in the energy density parameters are optimized by selecting clusters with redshift upper cut-offs in the range 0.55 approx. less than 1. Subject headings: cosmological parameters - cosmology: theory - galaxies:clusters: general

  11. Environmental fatigue of an Al-Li-Cu alloy. Part 2: Microscopic hydrogen cracking processes

    NASA Technical Reports Server (NTRS)

    Piascik, Robert S.; Gangloff, Richard P.

    1992-01-01

    Based on a fractographic analysis of fatigue crack propagation (FCP) in Al-Li-Cu alloy 2090 stressed in a variety of inert and embrittling environments, microscopic crack paths are identified and correlated with intrinsic da/dN-delta K kinetics. FCP rates in 2090 are accelerated by hydrogen producing environments (pure water vapor, moist air, and aqueous NaCl), as defined in Part 1. For these cases, subgrain boundary fatigue cracking (SGC) dominates for delta K values where the crack tip process zone, a significant fraction of the cyclic plastic zone, is sufficiently large to envelop 5 micron subgrains in the unrecrystallized microstructure. SGC may be due to strong hydrogen trapping at T1 precipitates concentrated at sub-boundaries. At low delta K, the plastic zone diameter is smaller than the subgrain size and FCP progresses along (100) planes due to either local lattice decohesion or aluminum-lithium hydride cracking. For inert environments (vacuum, helium, and oxygen), or at high delta K where the hydrogen effect on da/dN is small, FCP is along (111) slip planes; this mode does not transition with increasing delta K and plastic zone size. The SGC and (100) crystallographic cracking modes, and the governing influence of the crack tip process zone volume (delta K), support hydrogen embrittlement rather than a surface film rupture and anodic dissolution mechanism for environmental FCP. Multi-sloped log da/dN-log delta K behavior is produced by changes in process zone hydrogen-microstructure interactions, and not by purely micromechanical-microstructure interactions, in contradiction to microstructural distance-based fatigue models.

  12. [Halos and multifocal intraocular lenses: origin and interpretation].

    PubMed

    Alba-Bueno, F; Vega, F; Millán, M S

    2014-10-01

    To present the theoretical and experimental characterization of the halo in multifocal intraocular lenses (MIOL). The origin of the halo in a MIOL is the overlaying of 2 or more images. Using geometrical optics, it can be demonstrated that the diameter of each halo depends on the addition of the lens (ΔP), the base power (P(d)), and the diameter of the IOL that contributes to the «non-focused» focus. In the image plane that corresponds to the distance focus, the halo diameter (δH(d)) is given by: δH(d)=d(pn) ΔP/P(d), where d(pn) is the diameter of the IOL that contributes to the near focus. Analogously, in the near image plane the halo diameter (δH(n)) is: δH(n)=d(pd) ΔP/P(d), where d(pd) is the diameter of the IOL that contributes to the distance focus. Patients perceive halos when they see bright objects over a relatively dark background. In vitro, the halo can be characterized by analyzing the intensity profile of the image of a pinhole that is focused by each of the foci of a MIOL. A comparison has been made between the halos induced by different MIOL of the same base power (20D) in an optical bench. As predicted by theory, the larger the addition of the MIOL, the larger the halo diameter. For large pupils and with MIOL with similar aspheric designs and addition (SN6AD3 vs ZMA00), the apodized MIOL has a smaller halo diameter than a non-apodized one in distance vision, while in near vision the size is very similar, but the relative intensity is higher in the apodized MIOL. When comparing lenses with the same diffractive design, but with different spherical-aspheric base design (SN60D3 vs SN6AD3), the halo in distance vision of the spherical MIOL is larger, while in near vision the spherical IOL induces a smaller halo, but with higher intensity due to the spherical aberration of the distance focus in the near image. In the case of a trifocal-diffractive IOL (AT LISA 839MP) the most noticeable characteristic is the double-halo formation due to the 2 non-focused powers. Copyright © 2013 Sociedad Española de Oftalmología. Published by Elsevier Espana. All rights reserved.

  13. Variations in the sonographic measurement techniques of BI-RADS 3 breast masses.

    PubMed

    Francisco, Juliana; Jales, Rodrigo Menezes; de Oliveira, André Desuó Bueno; Arguello, Carlos Henrique Francisco; Derchain, Sophie

    2017-06-01

    To evaluate the differences in sonographic (US) distance and volume measurements from different sonologists and identify the optimal parameters to avoid clinically relevant variations in the measurement of BI-RADS 3 breast masses. For this cross-sectional study with prospectively collected data, four physicians with various levels of experience in US, herein called sonologists, performed distance and volume US measurements of 80 masses classified as BI-RADS 3. The Cochran Q test was used to compare the matched sets of rates of clinically relevant variability between all pairs of sonologists' measurements. There were clinically relevant differences between sonologists in the measurements of the longest diameter (range, 17.5-43.7%, p = 0.003), the longest diameter perpendicular to the previous one (anteroposterior diameter) (17.5-33.7%, p = 0.06), the third diameter orthogonal to the plane defined by the previous two (transverse diameter) (28.7-55%, p = 0.001), and at least two of those three diameters (18.7-38.7%, p = 0.015). The smallest clinically relevant differences were observed with volume measurements (range of differences, 6.2-13.7%, p = 0.51). Volume measurement technique was associated with the least variations, whereas distance measurements, which are used routinely, were associated with unacceptable rates of clinically relevant variations. © 2016 Wiley Periodicals, Inc. J Clin Ultrasound 45:252-260, 2017. © 2017 Wiley Periodicals, Inc.

  14. Visualization and quantification of magnetic nanoparticles into vesicular systems by combined atomic and magnetic force microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dong, C.; Department of Physics, SAPIENZA University of Rome, Piazzale A. Moro 5, 00185, Rome; Corsetti, S.

    2015-06-23

    We report a phenomenological approach for the quantification of the diameter of magnetic nanoparticles (MNPs) incorporated in non-ionic surfactant vesicles (niosomes) using magnetic force microscopy (MFM). After a simple specimen preparation, i.e., by putting a drop of solution containing MNPs-loaded niosomes on flat substrates, topography and MFM phase images are collected. To attempt the quantification of the diameter of entrapped MNPs, the method is calibrated on the sole MNPs deposited on the same substrates by analyzing the MFM signal as a function of the MNP diameter (at fixed tip-sample distance) and of the tip-sample distance (for selected MNPs). After calibration,more » the effective diameter of the MNPs entrapped in some niosomes is quantitatively deduced from MFM images.« less

  15. Keratin capped silver nanoparticles - synthesis and characterization of a nanomaterial with desirable handling properties

    USDA-ARS?s Scientific Manuscript database

    Silver nanoparticles (NPs) were produced with keratin stabilizer and the NPs exhibited unimodal Gaussian distribution with average diameter of 3.5nm +/- 0.7 nm. The molecular mass of keratin stabilizer was 6-8 kDa. The mass of keratin capped NPs was >250 kDa to indicate the formation of crosslinked...

  16. A Distance Judgment Function Based on Space Perception Mechanisms: Revisiting Gilinsky's (1951) Equation

    ERIC Educational Resources Information Center

    Ooi, Teng Leng; He, Zijiang J.

    2007-01-01

    In her seminal article in "Psychological Review," A. S. Gilinsky (1951) successfully described the relationship between physical distance (D) and perceived distance (d) with the equation d = DA/(A + D), where A = constant. To understand its theoretical underpinning, the authors of the current article capitalized on space perception mechanisms…

  17. Effects of intrinsic aerobic capacity and ovariectomy on voluntary wheel running and nucleus accumbens dopamine receptor gene expression.

    PubMed

    Park, Young-Min; Kanaley, Jill A; Padilla, Jaume; Zidon, Terese; Welly, Rebecca J; Will, Matthew J; Britton, Steven L; Koch, Lauren G; Ruegsegger, Gregory N; Booth, Frank W; Thyfault, John P; Vieira-Potter, Victoria J

    2016-10-01

    Rats selectively bred for high (HCR) and low (LCR) aerobic capacity show a stark divergence in wheel running behavior, which may be associated with the dopamine (DA) system in the brain. HCR possess greater motivation for voluntary running along with greater brain DA activity compared to LCR. We recently demonstrated that HCR are not immune to ovariectomy (OVX)-associated reductions in spontaneous cage (i.e. locomotor) activity. Whether HCR and LCR rats differ in their OVX-mediated voluntary wheel running response is unknown. To determine whether HCR are protected from OVX-associated reduction in voluntary wheel running. Forty female HCR and LCR rats (age ~27weeks) had either SHM or OVX operations, and given access to a running wheel for 11weeks. Weekly wheel running distance was monitored throughout the intervention. Nucleus accumbens (NAc) was assessed for mRNA expression of DA receptors at sacrifice. Compared to LCR, HCR ran greater distance and had greater ratio of excitatory/inhibitory DA mRNA expression (both line main effects, P<0.05). Wheel running distance was significantly, positively correlated with the ratio of excitatory/inhibitory DA mRNA expression across animals. In both lines, OVX reduced wheel running (P<0.05). Unexpectedly, although HCR started with significantly greater voluntary wheel running, they had greater OVX-induced reduction in wheel running than LCR such that no differences were found 11weeks after OVX between HCROVX and LCROVX (interaction, P<0.05). This significant reduction in wheel running in HCR was associated with an OVX-mediated reduction in the ratio of excitatory/inhibitory DA mRNA expression. The DA system in the NAc region may play a significant role in motivation to run in female rats. Compared to LCR, HCR rats run significantly more, which associates with greater ratio of excitatory/inhibitory DA mRNA expression. However, despite greater inherent motivation to run and an associated brain DA mRNA expression profile, HCR rats are not protected against OVX-induced reduction in wheel running or OVX-mediated reduction in the ratio of excitatory/inhibitory DA receptor mRNA expression. OVX-mediated reduction in motivated physical activity may be partially explained by a reduced ratio of excitatory/inhibitory DA receptor mRNA expression for which intrinsic fitness does not confer protection. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Colloid characterization and in situ release in shallow groundwater under different hydrogeology conditions.

    PubMed

    Zhou, Jingjing; Liu, Dan; Zhang, Wenjing; Chen, Xuequn; Huan, Ying; Yu, Xipeng

    2017-06-01

    Changes to groundwater hydrodynamics and chemistry can lead to colloid release that can have a major impact on the groundwater environment. To analyze the effects of colloid release caused by artificial groundwater recharge, field and laboratory tests on colloid characterization and colloid release were conducted. The field tests were carried out at an artificial recharge test site in Shandong Province. In the field investigation, one recharge water sample and five groundwater samples were collected and filtered through three levels of ultrafiltration membranes, with pore sizes of 0.45 μm, 100 kDa, and 50 kDa. The field results indicated that the colloid mass concentrations in groundwater retained between membranes with pore sizes of 100 kDa-0.45 μm and 50 kDa-100 kDa were 19 and 62 mg/L, respectively. In recharge water, the colloid mass concentrations retained by 100-kDa-0.45-μm and 50-kDa-100-kDa membranes were 3 and 99 mg/L, respectively. Colloids detected on the ultrafiltration membranes were mainly inorganic between 100 kDa and 0.45 μm, and mainly organic between 50 and 100 kDa. Based on the field colloid investigation results, the organic colloid was chosen in the laboratory experiments to reveal its release behavior under different conditions. Porous media diameter, flux, ionic strength (IS), and ion valence were changed to determine their influences on organic colloid concentration outflow from undisturbed porous media. The experiment's results indicate that decreasing the diameter, and increasing the flux, ionic strength, and the number of divalent cations, can promote organic colloid release. The organic colloid release rate in the early stage was high and is thus likely to affect the quality of groundwater. The results provide a useful scientific basis for minimizing changes to hydrodynamic and hydrochemical conditions during artificial recharge, thus safeguarding groundwater quality.

  19. Individual tree-diameter growth model for the Northeastern United States

    Treesearch

    Richard M. Teck; Donald E. Hilt

    1991-01-01

    Describes a distance-independent individual-tree diameter growth model for the Northeastern United States. Diameter growth is predicted in two steps using a two parameter, sigmoidal growth function modified by a one parameter exponential decay function with species-specific coefficients. Coefficients are presented for 28 species groups. The model accounts for...

  20. Development of polyvinyl acetate thin films by electrospinning for sensor applications

    NASA Astrophysics Data System (ADS)

    Veerabhadraiah, Amith; Ramakrishna, Sridhar; Angadi, Gangadhar; Venkatram, Mamtha; Kanivebagilu Ananthapadmanabha, Vishnumurthy; Hebbale NarayanaRao, Narasimha Murthy; Munishamaiah, Krishna

    2017-10-01

    Electrospinning is an effective process for synthesis of polymer fibers with diameters ranging between nanometers and micrometers by employing electrostatic force developed due to application of high voltage. The present work aims to develop an electrospinning system and optimize the process parameters for synthesis of Polyvinyl Acetate thin films used for gas and humidity sensors. Taguchi's Design of Experiment was adopted considering three main factors at three different levels for optimization of process parameters. The factors considered were flow rate (0.5, 0.6 and 0.7 ml/h), voltage (18, 19 and 20 kV) and spinneret to collector distance (8, 9, 10 cm) with fiber diameter as the response factor. The main effect plots and interaction plots of the parameters were studied to determine the most influencing parameter. Flow rate was the most significant factor followed by spinneret to collector distance. Least fiber diameter of 24.83 nm was observed at 19 kV, 0.5 ml/h flow rate and 8 cm spinneret to collector distance. SEM images revealed uniform fiber diameter at lower flow rate while bead formation increased monotonically with rise in flow rate.

  1. Variation of the pressure limits of flame propagation with tube diameter for propane-air mixtures

    NASA Technical Reports Server (NTRS)

    Belles, Frank E; Simon, Dorothy M

    1951-01-01

    An investigation was made of the variation of the pressure limits of flame propagation with tube diameter for quiescent propane with tube diameter for quiescent propane-air mixtures. Pressure limits were measured in glass tubes of six different inside diameters, with a precise apparatus. Critical diameters for flame propagation were calculated and the effect of pressure was determined. The critical diameters depended on the pressure to the -0.97 power for stoichiometric mixtures. The pressure dependence decreased with decreasing propane concentration. Critical diameters were related to quenching distance, flame speeds, and minimum ignition energy.

  2. The spiral aftereffect : influence of stimulus size and viewing distance on the duration of illusory motion.

    DOT National Transportation Integrated Search

    1968-05-01

    The study examined some effects of stimulus size and distance on the persistence of one type of illusory motion, viz., the spiral aftereffect (SAE). Duration of SAE was investigated with stimuli of 2, 4, 8, 12, and 16 inches in diameter. The distance...

  3. Effects of intrinsic aerobic capacity and ovariectomy on voluntary wheel running and nucleus accumbens dopamine receptor gene expression

    PubMed Central

    Park, Young-Min; Kanaley, Jill A.; Padilla, Jaume; Zidon, Terese; Welly, Rebecca J.; Will, Matthew J.; Britton, Steven L.; Koch, Lauren G.; Ruegsegger, Gregory N.; Booth, Frank W.; Thyfault, John P.; Vieira-Potter, Victoria J.

    2016-01-01

    Rats selectively bred for high (HCR) and low (LCR) aerobic capacity show a stark divergence in wheel running behavior, which may be associated with dopamine (DA) system in the brain. HCR possess greater motivation for voluntary running along with greater brain DA activity compared to LCR. We recently demonstrated that HCR are not immune to ovariectomy (OVX)-associated reductions in spontaneous cage (i.e. locomotor) activity. Whether HCR and LCR rats differ in their OVX-mediated voluntary wheel running response is unknown. PURPOSE To determine whether HCR are protected from OVX-associated reduction in voluntary wheel running. METHODS Forty female HCR and LCR rats (age ~27 weeks) had either SHM or OVX operations, and given access to a running wheel for 11 weeks. Weekly wheel running distance was monitored throughout the intervention. Nucleus accumbens (NAc) was assessed for mRNA expression of DA receptors at sacrifice. RESULTS Compared to LCR, HCR ran greater distance and had greater ratio of excitatory/inhibitory DA mRNA expression (both line main effects, P<0.05). Wheel running distance was significantly, positively correlated with the ratio of excitatory/inhibitory DA mRNA expression across animals. In both lines, OVX reduced wheel running (P<0.05). Unexpectedly, although HCR started with significantly greater voluntary wheel running, they had greater OVX-induced reduction in wheel running than LCR such that no differences were found 11 weeks after OVX between HCROVX and LCROVX (interaction, P<0.05). This significant reduction in wheel running in HCR was associated with an OVX-mediated reduction in the ratio of excitatory/inhibitory DA mRNA expression. CONCLUSION DA system in the NAc region may play a significant role in motivation to run in female rats. Compared to LCR, HCR rats run significantly more, which associates with greater ratio of excitatory/inhibitory DA mRNA expression. However, despite greater inherent motivation to run and an associated brain DA mRNA expression profile, these HCR rats are not protected against OVX-induced reduction in wheel running. The impairment in wheel running in HCR rats may be partially explained by their reduced ratio of excitatory/inhibitory DA receptor mRNA expression. PMID:27297873

  4. Investigation of aluminum surface cleaning using cavitating fluid flow

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ralys, Aurimas; Striška, Vytautas; Mokšin, Vadim

    This paper investigates efficiency of specially designed atomizer used to spray water and cavitate microbubbles in water flow. Surface cleaning system was used to clean machined (grinded) aluminum surface from abrasive particles. It is established that cleaning efficiency depends on diameter of the diffuser, water pressure and distance between nozzle and metal surface. It is obtained that the best cleaning efficiency (100%) is achieved at pressure 36 bar, when diameter of diffuser is 0.4 mm and distance between nozzle and surface is 1 mm. It is also established that satisfactory cleaning efficiency (80%) is achieved not only when atomizer ismore » placed closer to metal surface, but also at larger (120 mm) distances.« less

  5. Porosity characterization of biodegradable porous poly (L-lactic acid) electrospun nanofibers

    NASA Astrophysics Data System (ADS)

    Valipouri, Afsaneh; Gharehaghaji, Ali Akbar; Alirezazadeh, Azam; Ravandi, Seyed Abdolkarim Hosseini

    2017-12-01

    Poly-L lactic acid (PLLA) is one of the mostly used fibers in biomedical applications as a biodegradable and biocompatible material. Porosity and fiber diameter distribution are governing factors that determine the performance of nanofibers. Present work aims at investigating the process parameters that are affecting porosity and diameter distribution of PLLA nanofibers. PLLA nanofibers were fabricated through electrospinning method using the solution of PLLA polymer/dichloromethane (DCM). Nanofibers with various fiber diameter distribution and porosity were made by changing of process parameters such as spinning distance (5, 10 and 15 cm), voltage (11 and 15 kV), solution concentration (10, 11 and 12 wt%) and feeding rate (0.3, 0.4 and 0.7 ml h-1). Image processing techniques (with Matlab R2017), surface analysis (with Mountainsmap7) and diameter distribution analysis (with Measurement software) were used to examine surface morphology of samples. The results showed that the fiber diameter distribution becomes wider with increasing the applied voltage and reducing the spinning distance. In the other hand, coarse fibers possessed larger pores while having irregular and fewer pores in comparison to fine fibers. The most uniform nano-web with high porous nanofibers was attained by the choice of the process parameters at the voltage of 11 kV, spinning distance of 15 cm, feeding rate of 0.4 ml h-1 and solution concentration of 10 wt%.

  6. Randomized Comparison of Paclitaxel-Eluting Balloon and Stenting Versus Plain Balloon Plus Stenting Versus Directional Atherectomy for Femoral Artery Disease (ISAR-STATH).

    PubMed

    Ott, Ilka; Cassese, Salvatore; Groha, Philipp; Steppich, Birgit; Hadamitzky, Martin; Ibrahim, Tareq; Kufner, Sebastian; Dewitz, Karl; Hiendlmayer, Regina; Laugwitz, Karl-Ludwig; Schunkert, Heribert; Kastrati, Adnan; Fusaro, Massimiliano

    2017-06-06

    Atherosclerosis in the superficial femoral artery is common in patients suffering from peripheral artery disease. Paclitaxel-eluting balloon (PEB) angioplasty, stenting, and directional atherectomy (DA) have provided new options for the treatment of superficial femoral artery disease; however, the comparative efficacy of these interventional strategies remains uncertain. One hundred and fifty-five patients with symptomatic peripheral artery disease due to de novo superficial femoral artery stenotic or occlusive lesions were randomized to treatment with plain balloon angioplasty (BA) followed by PEB angioplasty and stenting (n=48), BA and stenting (n=52), or DA with distal protection and bailout stenting (n=55). The primary end point of the study was percentage diameter stenosis after 6 months measured by angiography. Other end points included target lesion revascularization, thrombosis, ipsilateral amputation, binary restenosis, and all-cause mortality at 6 and 24 months. Baseline and lesion characteristics were comparable in all groups with a mean lesion length of 65.9±46.8 mm and 56% total occlusions. At 6 months angiography, the percent diameter stenosis was significantly lower in patients treated by PEB angioplasty and stenting (34±31%) as compared with BA angioplasty and stenting (56±29%, P =0.009) or DA (55±29%, P =0.007). Similarly, binary restenosis was significantly lower after treatment with PEB and stenting as compared with BA and stenting or DA. Clinical follow-up at 24 months revealed a lower risk for target lesion revascularization after PEB angioplasty and stenting as compared with BA and stenting or DA. We found no difference in terms of target lesion thrombosis and mortality among groups, and no patient underwent amputation. Treatment of de novo superficial femoral artery lesions with PEB angioplasty and stenting is superior to BA angioplasty and stenting or DA in terms of angiographic diameter stenosis at 6 months and target lesion revascularization at 24 months. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00986752. © 2017 American Heart Association, Inc.

  7. Training and Health. Leonardo da Vinci Series: Good Practices.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This document profiles programs in the fields of health and medicine that are offered through the European Commission's Leonardo da Vinci program. The following programs are profiled: (1) CYTOTRAIN (a transnational vocational training program in cervical cancer screening); (2) Apollo (a program of open and distance learning for paramedical…

  8. Distance-limited perpendicular distance sampling for coarse woody debris: theory and field results

    Treesearch

    Mark J. Ducey; Micheal S. Williams; Jeffrey H. Gove; Steven Roberge; Robert S. Kenning

    2013-01-01

    Coarse woody debris (CWD) has been identified as an important component in many forest ecosystem processes. Perpendicular distance sampling (PDS) is one of the several efficient new methods that have been proposed for CWD inventory. One drawback of PDS is that the maximum search distance can be very large, especially if CWD diameters are large or the volume factor...

  9. Ascending aortic elongation and the risk of dissection.

    PubMed

    Krüger, Tobias; Forkavets, Oksana; Veseli, Kujtim; Lausberg, Henning; Vöhringer, Luise; Schneider, Wilke; Bamberg, Fabian; Schlensak, Christian

    2016-08-01

    Unlike aneurysm formation, the role of ascending aortic elongation in the pathogenesis of Type A aortic dissection (TAD) is largely unclear. We investigated the morphology of healthy, dissected and predissection aortas with a focus on ascending aortic length. We retrospectively compared clinical and computer tomography angiography (CTA) data from TAD patients (n = 130), patients who developed a TAD in the further clinical course (preTAD, n = 16) and healthy control patients who received a CTA for non-aortic emergencies (n = 165). The length of the ascending aorta was defined as the distance between the sinotubular junction (STJ) and the brachiocephalic trunk (BCT) at the central line, the outer and inner curvature as well as the direct distance in the frontal and sagittal planes. Additionally, the aortic diameters were analysed. In the healthy controls, we found a positive correlation of age with the aortic diameter (r = 0.57) and aortic length (r = 0.42). The correlation of the respective parameters with the body size was negligible (r < 0.2). The median ascending aortic diameter at the height of the pulmonary artery in TAD (50 mm) was significantly (P < 0.001) larger compared with the respective diameter of the healthy aortas (34 mm). The diameter of the preTAD aortas (40 mm) was also significantly larger compared with the healthy controls. These proportions were similar in all the aortic diameters. The midline length of the healthy ascending aortas was 71 mm. In the preTAD and TAD aortas, the same values were 81 mm and 92 mm, respectively (both P < 0.001). We evaluated the linear distance between the STJ and the BCT in the frontal plane as an easy-to-measure parameter of aortic length. In the TAD aortas (108 mm) and preTAD aortas (97 mm), this distance was significantly longer compared with the healthy aortas (84 mm). Aortic diameter might not be an optimal parameter to predict dissection. Most aortas dissect at diameters below 55 mm. Both the TAD and preTAD aortas were elongated compared with the healthy controls. Thus, aortic elongation may play a role in the pathogenesis of and may be a risk factor for TAD. © The Author 2016. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. The morphology and electrical geometry of rat jaw-elevator motoneurones.

    PubMed Central

    Moore, J A; Appenteng, K

    1991-01-01

    1. The aim of this work was to quantify both the morphology and electrical geometry of the dendritic trees of jaw-elevator motoneurones. To do this we have made intracellular recordings from identified motoneurones in anaesthetized rats, determined their membrane properties and then filled them with horseradish peroxidase by ionophoretic ejection. Four neurones were subsequently fully reconstructed and the lengths and diameters of all the dendritic segments measured. 2. The mean soma diameter was 25 microns and values of mean dendritic length for individual cells ranged from 514 to 773 microns. Dendrites branched on average 9.1 times to produce 10.2 end-terminations. Dendritic segments could be represented as constant diameter cylinders between branch points. Values of dendritic surface area ranged from 1.08 to 2.52 x 10(5) microns 2 and values of dendritic to total surface area from 98 to 99%. 3. At branch points the ratio of the summed diameters of the daughter dendrites to the 3/2 power against the parent dendrite to the 3/2 power was exactly 1.0. Therefore the individual branch points could be collapsed into a single cylinder. Furthermore for an individual dendrite the diameter of this cylinder remained constant with increasing electrical distance from the soma. Thus individual dendrites can be represented electrically as cylinders of constant diameter. 4. However dendrites of a given neurone terminated at different electrical distances from the soma. The equivalent-cylinder diameter of the combined dendritic tree remained constant over the proximal half and then showed a pronounced reduction over the distal half. The reduction in equivalent diameter could be ascribed to the termination of dendrites at differing electrical distances from the soma. Therefore the complete dendritic tree of these motoneurones is best represented as a cylinder over the proximal half of their electrical length but as a cone over the distal half. PMID:1804966

  11. Updating Indiana Annual Forest Inventory and Analysis Plot Data Using Eastern Broadleaf Forest Diameter Growth Models

    Treesearch

    Veronica C. Lessard

    2001-01-01

    The Forest Inventory and Analysis (FIA) program of the North Central Research Station (NCRS), USDA Forest Service, has developed nonlinear, individual-tree, distance-independent annual diameter growth models. The models are calibrated for species groups and formulated as the product of an average diameter growth component and a modifier component. The regional models...

  12. A virus capsid-like nanocompartment that stores iron and protects bacteria from oxidative stress.

    PubMed

    McHugh, Colleen A; Fontana, Juan; Nemecek, Daniel; Cheng, Naiqian; Aksyuk, Anastasia A; Heymann, J Bernard; Winkler, Dennis C; Lam, Alan S; Wall, Joseph S; Steven, Alasdair C; Hoiczyk, Egbert

    2014-09-01

    Living cells compartmentalize materials and enzymatic reactions to increase metabolic efficiency. While eukaryotes use membrane-bound organelles, bacteria and archaea rely primarily on protein-bound nanocompartments. Encapsulins constitute a class of nanocompartments widespread in bacteria and archaea whose functions have hitherto been unclear. Here, we characterize the encapsulin nanocompartment from Myxococcus xanthus, which consists of a shell protein (EncA, 32.5 kDa) and three internal proteins (EncB, 17 kDa; EncC, 13 kDa; EncD, 11 kDa). Using cryo-electron microscopy, we determined that EncA self-assembles into an icosahedral shell 32 nm in diameter (26 nm internal diameter), built from 180 subunits with the fold first observed in bacteriophage HK97 capsid. The internal proteins, of which EncB and EncC have ferritin-like domains, attach to its inner surface. Native nanocompartments have dense iron-rich cores. Functionally, they resemble ferritins, cage-like iron storage proteins, but with a massively greater capacity (~30,000 iron atoms versus ~3,000 in ferritin). Physiological data reveal that few nanocompartments are assembled during vegetative growth, but they increase fivefold upon starvation, protecting cells from oxidative stress through iron sequestration. © 2014 The Authors.

  13. Gaussian Beam Intensity Flattener

    NASA Technical Reports Server (NTRS)

    Griffin, DeVon W.

    1998-01-01

    The goal of this investigation was to use commercial elements and extend the correction to a 1/e(sup 2) diameter of 3 mm over long propagation distances. Shafer discussed the use of spherical elements to generate a uniform beam to the 1/e diameter.

  14. Proximal femoral anatomy and collared stems in hip arthroplasty: is a single collar size sufficient?

    PubMed

    Bonin, Nicolas; Gedouin, Jean-Emmanuel; Pibarot, Vincent; Bejui-Hughues, Jacques; Bothorel, Hugo; Saffarini, Mo; Batailler, Cécile

    2017-10-03

    Even if the benefits of collars are unclear, they remain widely used, in several femoral stem designs. This study aimed to determine whether collar size should be proportional to hip dimensions and morphology. The hypothesis was that the collar should be larger for greater stem sizes and for varus femoral necks. Computed Tomography scans of 204 healthy hips were digitally analysed and manually templated to determine principle dimensions, appropriate stem size and model, as well as cortical distance at the femoral calcar (ideal collar size). Univariable analysis revealed that cortical distance was moderately correlated with mediolateral offset (r = 0.572; p < 0.0001) and stem model (r = 0.520; p < 0.0001). Cortical distance was weakly correlated with head diameter (r = 0.399; p < 0.0001), stem size (r = 0.200; p = 0.017), and patient gender (r = 0.361; p < 0.0001). Multivariable analysis confirmed that stem model (p < 0.0001) and head diameter (p = 0.0162) are directly correlated to cortical distance. We found that cortical distance along the femoral calcar is directly correlated with the model of the stem implanted ('standard' or 'varus') and with the head diameter. This cortical distance indicates optimal collar size, which would grant maximum calcar coverage without prosthetic overhang. Collar size should be proportional to the size of the operated hip, and should be larger for 'varus' stem models than for 'standard' stem models.

  15. 15 CFR 241.5 - Standard dimensions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... 133/8 115/8 Distance between heads 231/2 201/2 18 Circumference of bulge, outside measurement 581/2.../8 11 Distance between heads 23 20 171/2 Circumference of bulge, outside measurement 533/8 47 413/8... head 171/8 161/4 Effective diameter of head (see § 241.4) 163/4 157/8 Distance between heads 26 251/4...

  16. 15 CFR 241.5 - Standard dimensions.

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... 133/8 115/8 Distance between heads 231/2 201/2 18 Circumference of bulge, outside measurement 581/2.../8 11 Distance between heads 23 20 171/2 Circumference of bulge, outside measurement 533/8 47 413/8... head 171/8 161/4 Effective diameter of head (see § 241.4) 163/4 157/8 Distance between heads 26 251/4...

  17. 15 CFR 241.5 - Standard dimensions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... 133/8 115/8 Distance between heads 231/2 201/2 18 Circumference of bulge, outside measurement 581/2.../8 11 Distance between heads 23 20 171/2 Circumference of bulge, outside measurement 533/8 47 413/8... head 171/8 161/4 Effective diameter of head (see § 241.4) 163/4 157/8 Distance between heads 26 251/4...

  18. 15 CFR 241.5 - Standard dimensions.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... 133/8 115/8 Distance between heads 231/2 201/2 18 Circumference of bulge, outside measurement 581/2.../8 11 Distance between heads 23 20 171/2 Circumference of bulge, outside measurement 533/8 47 413/8... head 171/8 161/4 Effective diameter of head (see § 241.4) 163/4 157/8 Distance between heads 26 251/4...

  19. 15 CFR 241.5 - Standard dimensions.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... 133/8 115/8 Distance between heads 231/2 201/2 18 Circumference of bulge, outside measurement 581/2.../8 11 Distance between heads 23 20 171/2 Circumference of bulge, outside measurement 533/8 47 413/8... head 171/8 161/4 Effective diameter of head (see § 241.4) 163/4 157/8 Distance between heads 26 251/4...

  20. Individual-tree diameter growth model for managed, even-aged, upland oak stands

    Treesearch

    Donald E. Hilt

    1983-01-01

    A distance-independent, individual-tree diameter growth model was developed for managed, even-aged, upland oak stands. The 5-year basal-area growth of individual trees is first modeled as a function of dbh squared for given stands. Parameters from these models are then modeled as a function of mean stand diameter, percent stocking of the stand, and site index. A...

  1. Cosmic distance duality and cosmic transparency

    NASA Astrophysics Data System (ADS)

    Nair, Remya; Jhingan, Sanjay; Jain, Deepak

    2012-12-01

    We compare distance measurements obtained from two distance indicators, Supernovae observations (standard candles) and Baryon acoustic oscillation data (standard rulers). The Union2 sample of supernovae with BAO data from SDSS, 6dFGS and the latest BOSS and WiggleZ surveys is used in search for deviations from the distance duality relation. We find that the supernovae are brighter than expected from BAO measurements. The luminosity distances tend to be smaller then expected from angular diameter distance estimates as also found in earlier works on distance duality, but the trend is not statistically significant. This further constrains the cosmic transparency.

  2. Developing lignin-based bio-nanofibers by centrifugal spinning technique.

    PubMed

    Stojanovska, Elena; Kurtulus, Mustafa; Abdelgawad, Abdelrahman; Candan, Zeki; Kilic, Ali

    2018-07-01

    Lignin-based nanofibers were produced via centrifugal spinning from lignin-thermoplastic polyurethane polymer blends. The most suitable process parameters were chosen by optimization of the rotational speed, nozzle diameter and spinneret-to-collector distance using different blend ratios of the two polymers at different total polymer concentrations. The basic characteristics of polymer solutions were enlightened by their viscosity and surface tension. The morphology of the fibers produced was characterized by SEM, while their thermal properties by DSC and TG analysis. Multiply regression was used to determine the parameters that have higher impact on the fiber diameter. It was possible to obtain thermally stable lignin/polyurethane nanofibers with diameters below 500nm. From the aspect of spinnability, 1:1 lignin/TPU contents were shown to be more feasible. On the other side, the most suitable processing parameters were found to be angular velocity of 8500rpm for nozzles of 0.5mm diameter and working distance of 30cm. Copyright © 2018 Elsevier B.V. All rights reserved.

  3. Arrays of size and distance controlled platinum nanoparticles fabricated by a colloidal method

    NASA Astrophysics Data System (ADS)

    Manzke, Achim; Vogel, Nicolas; Weiss, Clemens K.; Ziener, Ulrich; Plettl, Alfred; Landfester, Katharina; Ziemann, Paul

    2011-06-01

    Based on emulsion polymerization in the presence of a Pt complex, polystyrene (PS) particles were prepared exhibiting a well defined average diameter with narrow size-distribution. Furthermore, the colloids contain a controlled concentration of the Pt precursor complex. Optimized coating of Si substrates with such colloids leads to extended areas of hexagonally ordered close-packed PS particles. Subsequent application of plasma etching and annealing steps allows complete removal of the PS carriers and in parallel nucleation and growth of Pt nanoparticles (NPs) which are located at the original center of the PS colloids. In this way, hexagonally arranged spherical Pt NPs are obtained with controlled size and interparticle distances demonstrating variability and precision with so far unknown parameter scalability. This control is demonstrated by the fabrication of Pt NP arrays at a fixed particle distance of 185 nm while systematically varying the diameters between 8 and 15 nm. Further progress could be achieved by seeded emulsion polymerization. Here, Pt loaded PS colloids of 130 nm were used as seeds for a subsequent additional emulsion polymerization, systematically enlarging the diameter of the PS particles. Applying the plasma and annealing steps as above, in this way hexagonally ordered arrays of 9 nm Pt NPs could be obtained at distances up to 260 nm. To demonstrate their stability, such Pt particles were used as etching masks during reactive ion etching thereby transferring their hexagonal pattern into the Si substrate resulting in corresponding arrays of nanopillars.Based on emulsion polymerization in the presence of a Pt complex, polystyrene (PS) particles were prepared exhibiting a well defined average diameter with narrow size-distribution. Furthermore, the colloids contain a controlled concentration of the Pt precursor complex. Optimized coating of Si substrates with such colloids leads to extended areas of hexagonally ordered close-packed PS particles. Subsequent application of plasma etching and annealing steps allows complete removal of the PS carriers and in parallel nucleation and growth of Pt nanoparticles (NPs) which are located at the original center of the PS colloids. In this way, hexagonally arranged spherical Pt NPs are obtained with controlled size and interparticle distances demonstrating variability and precision with so far unknown parameter scalability. This control is demonstrated by the fabrication of Pt NP arrays at a fixed particle distance of 185 nm while systematically varying the diameters between 8 and 15 nm. Further progress could be achieved by seeded emulsion polymerization. Here, Pt loaded PS colloids of 130 nm were used as seeds for a subsequent additional emulsion polymerization, systematically enlarging the diameter of the PS particles. Applying the plasma and annealing steps as above, in this way hexagonally ordered arrays of 9 nm Pt NPs could be obtained at distances up to 260 nm. To demonstrate their stability, such Pt particles were used as etching masks during reactive ion etching thereby transferring their hexagonal pattern into the Si substrate resulting in corresponding arrays of nanopillars. Electronic supplementary information (ESI) available: Detailed description of the experimental part (S1-S4) platinum concentration inside the polymer particles synthesized by a seeded polymerization from the same seed particles measured by ICP-OES (Fig. S1 and S5); SEM image of Pt complex containing PS particles after oxygen plasma treatment (Fig. S2 and S6); effect of hydrofluoric acid treatment on silicon oxide elevation under Pt NPs (Fig. S3 and S6); SEM images demonstrating the variability of Pt NP distance while keeping the diameter constant (Fig. S4 and S8); results of experimental determination of Pt content by ICP-OES (Tables S1 and S9); diameter of the particles at different fabrication states (Tables S2 and S10). See DOI: 10.1039/c1nr10169b

  4. Effects of electrode distance and nature of electrolyte on the diameter of titanium dioxide nanotube

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abbasi, S., E-mail: sum.abbasi@gmail.com; Mohamed, N. M., E-mail: noranimuti-mohamed@petronas.com.my; Singh, B. S. M., E-mail: balbir@petronas.com.my

    2015-07-22

    The titanium nanotubes were synthesized using viscous electrolytes consisting of ethylene glycol and non-viscous electrolytes consisting of aqueous solution of hydrofluoric acid. Sodium fluoride and ammonium fluoride were utilized as the source of fluorine ions. The samples were then characterized by field emission scanning electron microscope (FE-SEM). Their morphologies were investigated under different anodic potentials and various electrolyte compositions. It was found out that nanotubes can be obtained in fluoride ions and morphology is dependent on various parameters like anodic potential, time, electrolyte composition and the effects by varying the distance between the electrodes on the morphology was also investigated.more » It was found that by altering the distance between the electrodes, change in the diameter and the porosity was observed.« less

  5. Constraining smoothness parameter and the DD relation of Dyer-Roeder equation with supernovae

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yang, Xi; Yu, Hao-Ran; Zhang, Tong-Jie, E-mail: yangwds@mail.bnu.edu.cn, E-mail: yu@bnu.edu.cn, E-mail: tjzhang@bnu.edu.cn

    2013-06-01

    Our real universe is locally inhomogeneous. Dyer and Roeder introduced the smoothness parameter α to describe the influence of local inhomogeneity on angular diameter distance, and they obtained the angular diameter distance-redshift approximate relation (Dyer-Roeder equation) for locally inhomogeneous universe. Furthermore, the Distance-Duality (DD) relation, D{sub L}(z)(1+z){sup −2}/D{sub A}(z) = 1, should be valid for all cosmological models that are described by Riemannian geometry, where D{sub L} and D{sub A} are, respectively, the luminosity and angular distance distances. Therefore, it is necessary to test whether if the Dyer-Roeder approximate equation can satisfy the Distance-Duality relation. In this paper, we usemore » Union2.1 SNe Ia data to constrain the smoothness parameter α and test whether the Dyer-Roeder equation meet the DD relation. By using χ{sup 2} minimization, we get α = 0.92{sub −0.32}{sup +0.08} at 1σ and 0.92{sub −0.65}{sup +0.08} at 2σ, and our results show that the Dyer-Roeder equation is in good consistency with the DD relation at 1σ.« less

  6. Molar intercuspal dimensions: genetic input to phenotypic variation.

    PubMed

    Townsend, G; Richards, L; Hughes, T

    2003-05-01

    Molecular studies indicate that epigenetic events are important in determining how the internal enamel epithelium folds during odontogenesis. Since this process of folding leads to the subsequent arrangement of cusps on molar teeth, we hypothesized that intercuspal distances of human molar teeth would display greater phenotypic variation but lower heritabilities than overall crown diameters. Intercuspal distances and maximum crown diameters were recorded from digitized images of dental casts in 100 monozygotic and 74 dizygotic twin pairs. Intercuspal distances displayed less sexual dimorphism in mean values but greater relative variability and fluctuating asymmetry than overall crown measures. Correlations between intercuspal distances and overall crown measures were low. Models incorporating only environmental effects accounted for observed variation in several intercuspal measures. For those intercuspal variables displaying significant additive genetic variance, estimates of heritability ranged from 43 to 79%, whereas those for overall crown size were higher generally, ranging from 60 to 82%. Our finding of high phenotypic variation in intercuspal distances with only moderate genetic contribution is consistent with substantial epigenetic influence on the progressive folding of the internal enamel epithelium, following formation of the primary and secondary enamel knots.

  7. Prevalence and morphometric analysis of three-rooted mandibular first molars in a Brazilian subpopulation

    PubMed Central

    Rodrigues, Clarissa Teles; de Oliveira-Santos, Christiano; Bernardineli, Norberti; Duarte, Marco Antonio Hungaro; Bramante, Clovis Monteiro; Minotti-Bonfante, Paloma Gagliardi; Ordinola-Zapata, Ronald

    2016-01-01

    ABSTRACT The knowledge of the internal anatomy of three-rooted mandibular molars may help clinicians to diagnose and plan the root canal treatment in order to provide adequate therapy when this variation is present. Objectives: To determine the prevalence of three-rooted mandibular molars in a Brazilian population using cone beam computed tomography (CBCT) and to analyze the anatomy of mandibular first molars with three roots through micro-CT. Material and Methods: CBCT images of 116 patients were reviewed to determine the prevalence of three-rooted first mandibular molars in a Brazilian subpopulation. Furthermore, with the use of micro-CT, 55 extracted three-rooted mandibular first molars were scanned and reconstructed to assess root length, distance between canal orifices, apical diameter, Vertucci's classification, presence of apical delta, number of foramina and furcations, lateral and accessory canals. The distance between the orifice on the pulp chamber floor and the beginning of the curvature and the angle of canal curvature were analyzed in the distolingual root. Data were compared using the Kruskal-Wallis test (α=0.05). Results: The prevalence of three-rooted mandibular first molars was of 2.58%. Mesial roots showed complex distribution of the root canal system in comparison to the distal roots. The median of major diameters of mesiobuccal, mesiolingual and single mesial canals were: 0.34, 0.41 and 0.60 mm, respectively. The higher values of major diameters were found in the distobuccal canals (0.56 mm) and the lower diameters in the distolingual canals (0.29 mm). The lowest orifice distance was found between the mesial canals (MB-ML) and the highest distance between the distal root canals (DB-DL). Almost all distal roots had one root canal and one apical foramen with few accessory canals. Conclusions: Distolingual root generally has short length, severe curvature and a single root canal with low apical diameter. PMID:27812625

  8. An Examination of Diameter Density Prediction with k-NN and Airborne Lidar

    DOE PAGES

    Strunk, Jacob L.; Gould, Peter J.; Packalen, Petteri; ...

    2017-11-16

    While lidar-based forest inventory methods have been widely demonstrated, performances of methods to predict tree diameters with airborne lidar (lidar) are not well understood. One cause for this is that the performance metrics typically used in studies for prediction of diameters can be difficult to interpret, and may not support comparative inferences between sampling designs and study areas. To help with this problem we propose two indices and use them to evaluate a variety of lidar and k nearest neighbor (k-NN) strategies for prediction of tree diameter distributions. The indices are based on the coefficient of determination ( R 2),more » and root mean square deviation (RMSD). Both of the indices are highly interpretable, and the RMSD-based index facilitates comparisons with alternative (non-lidar) inventory strategies, and with projects in other regions. K-NN diameter distribution prediction strategies were examined using auxiliary lidar for 190 training plots distribute across the 800 km 2 Savannah River Site in South Carolina, USA. In conclusion, we evaluate the performance of k-NN with respect to distance metrics, number of neighbors, predictor sets, and response sets. K-NN and lidar explained 80% of variability in diameters, and Mahalanobis distance with k = 3 neighbors performed best according to a number of criteria.« less

  9. An Examination of Diameter Density Prediction with k-NN and Airborne Lidar

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Strunk, Jacob L.; Gould, Peter J.; Packalen, Petteri

    While lidar-based forest inventory methods have been widely demonstrated, performances of methods to predict tree diameters with airborne lidar (lidar) are not well understood. One cause for this is that the performance metrics typically used in studies for prediction of diameters can be difficult to interpret, and may not support comparative inferences between sampling designs and study areas. To help with this problem we propose two indices and use them to evaluate a variety of lidar and k nearest neighbor (k-NN) strategies for prediction of tree diameter distributions. The indices are based on the coefficient of determination ( R 2),more » and root mean square deviation (RMSD). Both of the indices are highly interpretable, and the RMSD-based index facilitates comparisons with alternative (non-lidar) inventory strategies, and with projects in other regions. K-NN diameter distribution prediction strategies were examined using auxiliary lidar for 190 training plots distribute across the 800 km 2 Savannah River Site in South Carolina, USA. In conclusion, we evaluate the performance of k-NN with respect to distance metrics, number of neighbors, predictor sets, and response sets. K-NN and lidar explained 80% of variability in diameters, and Mahalanobis distance with k = 3 neighbors performed best according to a number of criteria.« less

  10. Anatomical study of the internal nasal branch of the infraorbital nerve: Application to Minimizing Nerve Damage With Surgery In and Around the Nose.

    PubMed

    Iwanaga, Joe; Watanabe, Koichi; Henry, Brandon; Tomaszewski, Krzysztof A; Walocha, Jerzy A; Oskouian, Rod J; Tubbs, R Shane

    2017-09-01

    The internal nasal branch of the infraorbital nerve (ION) runs down the nose and around the ala to be distributed to the nasal septum and vestibule. The aim of this study was to measure the internal nasal branch around the ala of the nose and discuss its possible relevance in clinical/surgical practice. Twelve sides from seven specimens derived from fresh frozen and embalmed Caucasian cadaveric heads were dissected. The specimens included three males and four females. The ages of the cadavers at death ranged from 65 to 84 years. The diameter of the internal nasal branch, horizontal distance from the lateral contour of the ala (Point A) to the branch (distance H) and vertical distance from the bottom part of the ala (Point B) to the branch (distance V) were recorded. Distance H ranged from -1.6 to 1.5 mm on right sides and -1.0 to 1.5 mm on left sides. The diameter of the nerves at Point A ranged from 1.3 to 1.8 mm on right sides and 1.3 to 1.6 mm on left sides. Distance V ranged from -1.5 to 1.0 mm on right sides and -2.3 to 1.1 mm on left sides. The diameter of the nerves at Point B ranged from 0.7 to 1.3 mm on right sides and 0.8 to 1.2 mm on left sides. The results of this study are the first to detail the topography of the internal nasal branch of the ION. Clin. Anat. 30:817-820, 2017. © 2017Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  11. Peri-implant soft tissue and marginal bone adaptation on implant with non-matching healing abutments: micro-CT analysis.

    PubMed

    Finelle, Gary; Papadimitriou, Dimitrios E V; Souza, André B; Katebi, Negin; Gallucci, German O; Araújo, Mauricio G

    2015-04-01

    To assess (i) the outcome of changing the horizontal-offset dimension on the peri-implant soft tissues and the crestal bone and (ii) the effect of different healing abutments (flared vs. straight) on the marginal peri-implant soft tissues and crestal bone. Two-piece dental implants diameters of 3.5 and 4.5 mm were placed at least 1 mm subcrestal in five beagle dogs. Three different investigational groups: (i) 3.5-mm-diameter implant with narrow healing abutment (3.5N), (ii) 4.5-mm-diameter implant with narrow healing abutment (4.5N), and (iii) 3.5-mm-diameter implant with wide healing abutment (3.5W), were assessed. After 4 months of healing, the vertical distance from the marginal crestal bone (MB) to the implant shoulder (IS); the vertical distance from the IS to the first bone-to-implant contact; and the horizontal distance of bone ingrowth on the implant platform were measured with a high-resolution micro-CT (Xradia MicroXCT-200 system). Implants with a narrow healing caps showed an interproximal MB located between 0 and 1 mm above the implant shoulder, while the 3.5W group exhibits a mean value -0.50 mm. As all implants in group 3.5N presented a fBIC located at the level of the IS. For the 4.5N group, the mean fBIC-IS distance was -0.52 mm apically to the IS. For the 3.5WC group, the mean fBIC-IS distance was -1.42 mm. Horizontal bone apposition was only observed for the 3.5N group and the 4.5N group. The dimension of the horizontal offset would play a minimal role in reducing bone remodeling, whereas the configuration of the transmucosal component would directly influence marginal bone remodeling. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  12. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jee, I.; Komatsu, E.; Suyu, S.H., E-mail: ijee@mpa-garching.mpg.de, E-mail: komatsu@mpa-garching.mpg.de, E-mail: suyu@asiaa.sinica.edu.tw

    The distance-redshift relation plays a fundamental role in constraining cosmological models. In this paper, we show that measurements of positions and time delays of strongly lensed images of a background galaxy, as well as those of the velocity dispersion and mass profile of a lens galaxy, can be combined to extract the angular diameter distance of the lens galaxy. Physically, as the velocity dispersion and the time delay give a gravitational potential (GM/r) and a mass (GM) of the lens, respectively, dividing them gives a physical size (r) of the lens. Comparing the physical size with the image positions ofmore » a lensed galaxy gives the angular diameter distance to the lens. A mismatch between the exact locations at which these measurements are made can be corrected by measuring a local slope of the mass profile. We expand on the original idea put forward by Paraficz and Hjorth, who analyzed singular isothermal lenses, by allowing for an arbitrary slope of a power-law spherical mass density profile, an external convergence, and an anisotropic velocity dispersion. We find that the effect of external convergence cancels out when dividing the time delays and velocity dispersion measurements. We derive a formula for the uncertainty in the angular diameter distance in terms of the uncertainties in the observables. As an application, we use two existing strong lens systems, B1608+656 (z{sub L}=0.6304) and RXJ1131−1231 (z{sub L}=0.295), to show that the uncertainty in the inferred angular diameter distances is dominated by that in the velocity dispersion, σ{sup 2}, and its anisotropy. We find that the current data on these systems should yield about 16% uncertainty in D{sub A} per object. This improves to 13% when we measure σ{sup 2} at the so-called sweet-spot radius. Achieving 7% is possible if we can determine σ{sup 2} with 5% precision.« less

  13. Testing Gravity and Cosmic Acceleration with Galaxy Clustering

    NASA Astrophysics Data System (ADS)

    Kazin, Eyal; Tinker, J.; Sanchez, A. G.; Blanton, M.

    2012-01-01

    The large-scale structure contains vast amounts of cosmological information that can help understand the accelerating nature of the Universe and test gravity on large scales. Ongoing and future sky surveys are designed to test these using various techniques applied on clustering measurements of galaxies. We present redshift distortion measurements of the Sloan Digital Sky Survey II Luminous Red Galaxy sample. We find that when combining the normalized quadrupole Q with the projected correlation function wp(rp) along with cluster counts (Rapetti et al. 2010), results are consistent with General Relativity. The advantage of combining Q and wp is the addition of the bias information, when using the Halo Occupation Distribution framework. We also present improvements to the standard technique of measuring Hubble expansion rates H(z) and angular diameter distances DA(z) when using the baryonic acoustic feature as a standard ruler. We introduce clustering wedges as an alternative basis to the multipole expansion and show that it yields similar constraints. This alternative basis serves as a useful technique to test for systematics, and ultimately improve measurements of the cosmic acceleration.

  14. Image quality comparison of two multifocal IOLs: influence of the pupil.

    PubMed

    García-Domene, Mari Carmen; Felipe, Adelina; Peris-Martínez, Cristina; Navea, Amparo; Artigas, Jose M; Pons, Álvaro M

    2015-04-01

    To evaluate the effect of pupil size on image quality of a sectorial multifocal intraocular lens (IOL), the Lentis Mplus (Oculentis GmbH, Berlin, Germany), and the Acri.LISA IOL (Carl Zeiss Meditec, Jena, Germany). The authors measured the MTFs of the Lentis Mplus LS-312 IOL and the Acri.LISA 366D IOL with three different sizes of pupil diameters: 3, 4, and 5 mm. The MTF was calculated from the cross-line spread function recorded with the OPAL Vector System (Image Science Ltd., Oxford, UK) by using fast Fourier-transform techniques. In distance focus, the image quality provided by the Lentis Mplus IOL was better than that of the Acri. LISA IOL with all pupil diameters. In near focus, the MTF of the Acri.LISA IOL was better with a 3-mm pupil, but poor with larger pupils. The aberration effect was equal in both IOLs in distance focus, but in near focus and with a 3-mm pupil, the Acri.LISA IOL was less affected by the aberration than the Lentis Mplus IOL. The Lentis Mplus IOL provides better distance image quality than the Acri.LISA IOL, whereas the near image quality of the Acri.LISA IOL is better with small-pupil diameter. The sectorial design makes this IOL more suitable for patients with a pupil diameter greater than 3 mm. Copyright 2015, SLACK Incorporated.

  15. Non-Contact EDDY Current Hole Eccentricity and Diameter Measurement

    NASA Technical Reports Server (NTRS)

    Chern, E. James

    1998-01-01

    Precision holes are among the most critical features of a mechanical component. Deviations from permissible tolerances can impede operation and result in unexpected failure. We have developed an automated non-contact eddy current hole diameter and eccentricity measuring system. The operating principle is based on the eddy current lift-off effect, which is the coil impedance as a function of the distance between the coil and the test object. An absolute eddy current probe rotates in the hole. The impedance of each angular position is acquired and input to the computer for integration and analysis. The eccentricity of the hole is the profile of the impedance as a function of angular position as compared to a straight line, an ideal hole. The diameter of the hole is the sum of the diameter of the probe and twice the distance-calibrated impedance. An eddy current image is generated by integrating angular scans for a plurality of depths between the top and bottom to display the eccentricity profile. This system can also detect and image defects in the hole. The method for non-contact eddy current hole diameter and eccentricity measurement has been granted a patent by the U.S. Patent and Trademark Office.

  16. All-distance visual acuity and contrast visual acuity in eyes with a refractive multifocal intraocular lens with minimal added power.

    PubMed

    Hayashi, Ken; Yoshida, Motoaki; Hayashi, Hideyuki

    2009-03-01

    To compare visual acuity (VA) from far to near distances, photopic and mesopic contrast VA, and contrast VA in the presence of a glare source (glare VA), between eyes with a new refractive multifocal intraocular lens (IOL) with added power of only +3.0 diopters and those with a monofocal IOL. Comparative, nonrandomized, interventional study. Forty-four eyes of 22 patients who were scheduled for implantation of a refractive multifocal IOL (Hoya SFX MV1; Tokyo, Japan) and 44 eyes of 22 patients scheduled for implantation of a monofocal IOL. All patients underwent phacoemulsification with bilateral implantation of either multifocal or monofocal IOLs. At approximately 3 months after surgery, monocular and binocular VA from far to near distances was measured using the all-distance vision tester (Kowa AS-15; Tokyo, Japan), whereas photopic and mesopic contrast VA and glare VA were examined using the Contrast Sensitivity Accurate Tester (Menicon CAT-2000, Nagoya, Japan). Pupillary diameter and the degree of IOL decentration and tilt were correlated with VA at all distances. Mean VA in both the multifocal and monofocal IOL groups decreased gradually from far to near distances. When comparing the 2 groups, however, both uncorrected and best distance-corrected intermediate VA at 0.5 m and near VA at 0.3 m in the multifocal IOL group were significantly better than those in the monofocal IOL group (P

  17. Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis.

    PubMed

    Frisardi, Gianni; Barone, Sandro; Razionale, Armando V; Paoli, Alessandro; Frisardi, Flavio; Tullio, Antonio; Lumbau, Aurea; Chessa, Giacomo

    2012-05-29

    A fundamental pre-requisite for the clinical success in dental implant surgery is the fast and stable implant osseointegration. The press-fit phenomenon occurring at implant insertion induces biomechanical effects in the bone tissues, which ensure implant primary stability. In the field of dental surgery, the understanding of the key factors governing the osseointegration process still remains of utmost importance. A thorough analysis of the biomechanics of dental implantology requires a detailed knowledge of bone mechanical properties as well as an accurate definition of the jaw bone geometry. In this work, a CT image-based approach, combined with the Finite Element Method (FEM), has been used to investigate the effect of the drill size on the biomechanics of the dental implant technique. A very accurate model of the human mandible bone segment has been created by processing high resolution micro-CT image data. The press-fit phenomenon has been simulated by FE analyses for different common drill diameters (DA=2.8 mm, DB=3.3 mm, and DC=3.8 mm) with depth L=12 mm. A virtual implant model has been assumed with a cylindrical geometry having height L=11 mm and diameter D=4 mm. The maximum stresses calculated for drill diameters DA, DB and DC have been 12.31 GPa, 7.74 GPa and 4.52 GPa, respectively. High strain values have been measured in the cortical area for the models of diameters DA and DB, while a uniform distribution has been observed for the model of diameter DC . The maximum logarithmic strains, calculated in nonlinear analyses, have been ϵ=2.46, 0.51 and 0.49 for the three models, respectively. This study introduces a very powerful, accurate and non-destructive methodology for investigating the effect of the drill size on the biomechanics of the dental implant technique.Further studies could aim at understanding how different drill shapes can determine the optimal press-fit condition with an equally distributed preload on both the cortical and trabecular structure around the implant.

  18. Monte Carlo simulation of the influence of pressure and target-substrate distance on the sputtering process for metal and semiconductor layers

    NASA Astrophysics Data System (ADS)

    Bouazza, Abdelkader; Settaouti, Abderrahmane

    2016-07-01

    The energy and the number of particles arriving at the substrate during physical vapor deposition (PVD) are in close relation with divers parameters. In this work, we present the influence of the distance between the target and substrate and the gas pressure in the sputtering process of deposited layers of metals (Cu, Al and Ag) and semiconductors (Ge, Te and Si) for substrate diameter of 40 cm and target diameter of 5 cm. The nascent sputter flux, the flux of the atoms and their energy arriving at the substrate have been simulated by Monte Carlo codes. A good agreement between previous works of other groups and our simulations for sputter pressures (0.3-1 Pa) and target-substrate distances (8-20 cm) is obtained.

  19. Amorphous iron–chromium oxide nanoparticles with long-term stability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Iacob, Mihail; Institute of Chemistry of ASM, Academiei str. 3, Chisinau 2028, Republic of Moldova; Cazacu, Maria, E-mail: mcazacu@icmpp.ro

    2015-05-15

    Highlights: • Fe–Cr oxide nanoparticles with pre-established metals ratio were obtained. • The amorphous state and its long-term stability were highlighted by X-ray diffraction. • The average diameter of dried nanoparticles was 3.5 nm, as was estimated by TEM, AFM. • In hexane dispersion, nanoparticles with diameter in the range 2.33–4.85 nm were found. • Superparamagnetic state of NPs co-exists with diamagnetism of the organic layer. - Abstract: Iron–chromium nanoparticles (NPs) were obtained through the thermal decomposition of μ{sub 3}-oxo heterotrinuclear (FeCr{sub 2}O) acetate in the presence of sunflower oil and dodecylamine (DA) as surfactants. The average diameter of themore » NPs was 3.5 nm, as estimated on the basis of transmission electron microscopy and atomic force microscopy images. Both techniques revealed the formation of roughly approximated spheres with some irregularities and agglomerations in larger spherical assemblies of 50–100 nm. In hexane, NPs with diameters in the 2.33–4.85 nm range are individually dispersed, as emphasized by dynamic light scattering measurements. The amorphous nature of the product was emphasized by X-ray powder diffraction. The study of the magnetic properties shows the presence of superparamagnetic state of iron–chromium oxide NPs and the diamagnetic contribution from DA layer forming a shell of NPs.« less

  20. An independent Cepheid distance scale: Current status

    NASA Technical Reports Server (NTRS)

    Barnes, T. G., III

    1980-01-01

    An independent distance scale for Cepheid variables is discussed. The apparent magnitude and the visual surface brightness, inferred from an appropriate color index, are used to determine the angular diameter variation of the Cepheid. When combined with the linear displacement curve obtained from the integrated radial velocity curve, the distance and linear radius are determined. The attractiveness of the method is its complete independence of all other stellar distance scales, even though a number of practical difficulties currently exist in implementing the technique.

  1. Distance Learning. Leonardo da Vinci Series: Good Practices.

    ERIC Educational Resources Information Center

    Commission of the European Communities, Brussels (Belgium). Directorate-General for Education and Culture.

    This brochure, part of a series about good practices in vocational training in the European Union, describes 12 projects that use distance learning to promote lifelong learning in adults. The projects and their countries of origin are as follows: (1) 3D Project, training in the use of IT tools for 3D simulation and animation and practical…

  2. Fresnel Lens Solar Concentrator Design Based on Geometric Optics and Blackbody Radiation Equations

    NASA Technical Reports Server (NTRS)

    Watson, Michael D.; Jayroe, Robert, Jr.

    1999-01-01

    Fresnel lenses have been used for years as solar concentrators in a variety of applications. Several variables effect the final design of these lenses including: lens diameter, image spot distance from the lens, and bandwidth focused in the image spot. Defining the image spot as the geometrical optics circle of least confusion and applying blackbody radiation equations the spot energy distribution can be determined. These equations are used to design a fresnel lens to produce maximum flux for a given spot size, lens diameter, and image distance. This approach results in significant increases in solar efficiency over traditional single wavelength designs.

  3. Five-year radial growth of red oaks in mixed bottomland hardwood stands

    Treesearch

    Luben D. Dimov; Jim L. Chambers; Brian Roy Lockhart

    2008-01-01

    We studied the relationships among 5-year radial (diameter and basal area) growth of red oak (genus Quercus, subgenus Erythrobalanus) crop trees and predictor variables representing individual tree vigor, distance-dependant competition measures, and distance-independent competition measures. The red oaks we examined are...

  4. Diameter Tuning of β-Ga2O3 Nanowires Using Chemical Vapor Deposition Technique.

    PubMed

    Kumar, Mukesh; Kumar, Vikram; Singh, R

    2017-12-01

    Diameter tuning of [Formula: see text]-Ga 2 O 3 nanowires using chemical vapor deposition technique have been investigated under various experimental conditions. Diameter of root grown [Formula: see text]-Ga 2 O 3 nanowires having monoclinic crystal structure is tuned by varying separation distance between metal source and substrate. Effect of gas flow rate and mixer ratio on the morphology and diameter of nanowires has been studied. Nanowire diameter depends on growth temperature, and it is independent of catalyst nanoparticle size at higher growth temperature (850-900 °C) as compared to lower growth temperature (800 °C). These nanowires show changes in structural strain value with change in diameter. Band-gap of nanowires increases with decrease in the diameter.

  5. 24 CFR 3280.611 - Vents and venting.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... drain piping for each toilet shall be vented by a 11/2 inch minimum diameter vent or rectangular vent of..., connected to the toilet drain by one of the following methods: (i) A 11/2 inch diameter (min.) individual vent pipe or equivalent directly connected to the toilet drain within the distance allowed in § 3280...

  6. Structure of TatA Paralog, TatE, Suggests a Structurally Homogeneous Form of Tat Protein Translocase That Transports Folded Proteins of Differing Diameter

    PubMed Central

    Baglieri, Jacopo; Beck, Daniel; Vasisht, Nishi; Smith, Corinne J.; Robinson, Colin

    2012-01-01

    The twin-arginine translocation (Tat) system transports folded proteins across bacterial and plant thylakoid membranes. Most current models for the translocation mechanism propose the coalescence of a substrate-binding TatABC complex with a separate TatA complex. In Escherichia coli, TatA complexes are widely believed to form the translocation pore, and the size variation of TatA has been linked to the transport of differently sized substrates. Here, we show that the TatA paralog TatE can substitute for TatA and support translocation of Tat substrates including AmiA, AmiC, and TorA. However, TatE is found as much smaller, discrete complexes. Gel filtration and blue native electrophoresis suggest sizes between ∼50 and 110 kDa, and single-particle processing of electron micrographs gives size estimates of 70–90 kDa. Three-dimensional models of the two principal TatE complexes show estimated diameters of 6–8 nm and potential clefts or channels of up to 2.5 nm diameter. The ability of TatE to support translocation of the 90-kDa TorA protein suggests alternative translocation models in which single TatA/E complexes do not contribute the bulk of the translocation channel. The homogeneity of both the TatABC and the TatE complexes further suggests that a discrete Tat translocase can translocate a variety of substrates, presumably through the use of a flexible channel. The presence and possible significance of double- or triple-ring TatE forms is discussed. PMID:22190680

  7. Extended self-ordering regime in hard anodization and its application to make asymmetric AAO membranes for large pitch-distance nanostructures.

    PubMed

    Kim, Minwoo; Ha, Yoon-Cheol; Nguyen, Truong Nhat; Choi, Hae Young; Kim, Doohun

    2013-12-20

    We report here a fast and reliable hard anodization process to make asymmetric anodic aluminum oxide (AAO) membranes which can serve as a template for large pitch-distance nanostructures. In order to make larger pitch distances possible, the common burning failure associated with the high current density during the conventional constant voltage hard anodization, especially at a voltage higher than a known limit, i.e., 155 V for oxalic acid, was effectively suppressed by using a burning-protective agent. A new self-ordering regime beyond the voltage limit was observed with a different voltage-interpore distance relationship of 2.2 nm V(-1) compared to the reported 2.0 nm V(-1) for hard anodization. Combining a sulfuric acid mild anodization with this new regime of hard anodization, we further demonstrate a scalable process to make an asymmetric membrane with size up to ~47 mm in diameter and ~60 μm in thickness. This free-standing membrane can be used as a template for novel nanopatterned structures such as arrays of quantum dots, nanowires or nanotubes with diameters of a few tens of nanometers and pitch distance of over 400 nm.

  8. Extended self-ordering regime in hard anodization and its application to make asymmetric AAO membranes for large pitch-distance nanostructures

    NASA Astrophysics Data System (ADS)

    Kim, Minwoo; Ha, Yoon-Cheol; Nhat Nguyen, Truong; Choi, Hae Young; Kim, Doohun

    2013-12-01

    We report here a fast and reliable hard anodization process to make asymmetric anodic aluminum oxide (AAO) membranes which can serve as a template for large pitch-distance nanostructures. In order to make larger pitch distances possible, the common burning failure associated with the high current density during the conventional constant voltage hard anodization, especially at a voltage higher than a known limit, i.e., 155 V for oxalic acid, was effectively suppressed by using a burning-protective agent. A new self-ordering regime beyond the voltage limit was observed with a different voltage-interpore distance relationship of 2.2 nm V-1 compared to the reported 2.0 nm V-1 for hard anodization. Combining a sulfuric acid mild anodization with this new regime of hard anodization, we further demonstrate a scalable process to make an asymmetric membrane with size up to ˜47 mm in diameter and ˜60 μm in thickness. This free-standing membrane can be used as a template for novel nanopatterned structures such as arrays of quantum dots, nanowires or nanotubes with diameters of a few tens of nanometers and pitch distance of over 400 nm.

  9. Sanio's laws revisited. Size-dependent changes in the xylem architecture of trees.

    PubMed

    Mencuccini, Maurizio; Hölttä, Teemu; Petit, Giai; Magnani, Federico

    2007-11-01

    Early observations led Sanio [Wissen. Bot., 8, (1872) 401] to state that xylem conduit diameters and lengths in a coniferous tree increase from the apex down to a height below which they begin to decrease towards the tree base. Sanio's law of vertical tapering has been repeatedly tested with contradictory results and the debate over the scaling of conduit diameters with distance from the apex has not been settled. The debate has recently acquired new vigour, as an accurate knowledge of the vertical changes in wood anatomy has been shown to be crucial to scaling metabolic properties to plant and ecosystem levels. Contrary to Sanio's hypothesis, a well known model (MST, metabolic scaling theory) assumes that xylem conduits monotonically increase in diameter with distance from the apex following a power law. This has been proposed to explain the three-fourth power scaling between size and metabolism seen across plants. Here, we (i) summarized available data on conduit tapering in trees and (ii) propose a new numerical model that could explain the observed patterns. Data from 101 datasets grouped into 48 independent profiles supported the notions that phylogenetic group (angiosperms versus gymnosperms) and tree size strongly affected the vertical tapering of conduit diameter. For both angiosperms and gymnosperms, within-tree tapering also varied with distance from the apex. The model (based on the concept that optimal conduit tapering occurs when the difference between photosynthetic gains and wall construction costs is maximal) successfully predicted all three major empirical patterns. Our results are consistent with Sanio's law only for large trees and reject the MST assumptions that vertical tapering in conduit diameter is universal and independent of rank number.

  10. Diffraction of dust acoustic waves by a circular cylinder

    NASA Astrophysics Data System (ADS)

    Kim, S.-H.; Heinrich, J. R.; Merlino, R. L.

    2008-09-01

    The diffraction of dust acoustic (DA) waves around a long dielectric rod is observed using video imaging methods. The DA waves are spontaneously excited in a dusty plasma produced in a direct current glow discharge plasma. The rod acquires a negative charge that produces a coaxial dust void around it. The diameter of the void is the effective size of the "obstacle" encountered by the waves. The wavelength of the DA waves is approximately the size of the void. The observations are considered in relation to the classical problem of the diffraction of sound waves from a circular cylinder, a problem first analyzed by Lord Rayleigh [Theory of Sound, 2nd ed. (MacMillan, London, 1896)].

  11. Usefulness of Tricuspid Annular Diameter to Predict Late Right Sided Heart Failure in Patients With Left Ventricular Assist Device.

    PubMed

    Nakanishi, Koki; Homma, Shunichi; Han, Jiho; Takayama, Hiroo; Colombo, Paolo C; Yuzefpolskaya, Melana; Garan, Arthur R; Farr, Maryjane A; Kurlansky, Paul; Di Tullio, Marco R; Naka, Yoshifumi; Takeda, Koji

    2018-07-01

    Although late-onset right-sided heart failure is recognized as a clinical problem in the treatment of patients with left ventricular assist devices (LVADs), the mechanism and predictors are unknown. Tricuspid valve (TV) deformation leads to the restriction of the leaflet motion and decreased coaptation, resulting in a functional tricuspid regurgitation that may act as a surrogate marker of late right-sided heart failure. This study aimed to investigate the association of preoperative TV deformation (annulus dilatation and leaflet tethering) with late right-sided heart failure development after continuous-flow LVAD implantation. The study cohort consisted of 274 patients who underwent 2-dimensional echocardiography before LVAD implantation. TV annulus diameter and tethering distance were measured in an apical 4-chamber view. Late right-sided heart failure was defined as right-sided heart failure requiring readmission and medical and/or surgical treatment after initial LVAD implantation. During a mean follow-up of 25.1 ± 19.0 months after LVAD implantation, late right-sided heart failure occurred in 33 patients (12.0%). Multivariate Cox proportional hazard analysis demonstrated that TV annulus diameter (hazard ratio 1.221 per 1 mm, p <0.001) was significantly associated with late right-sided heart failure development, whereas leaflet tethering distance was not. The best cut-off value of the TV annular diameter was 41 mm (area under the curve 0.787). Kaplan-Meier analysis showed that patients with dilated TV annulus (TV annular diameter ≥41 mm) exhibited a significantly higher late right-sided heart failure occurrence than those without TV annular enlargement (log-rank p <0.001). In conclusion, preoperative TV annulus diameter, but not leaflet tethering distance, predicted the occurrence of late right-sided heart failure after LVAD implantation. Copyright © 2018 Elsevier Inc. All rights reserved.

  12. Hydrodynamic chromatography of polystyrene microparticles in micropillar array columns.

    PubMed

    Op de Beeck, Jeff; De Malsche, Wim; Vangelooven, Joris; Gardeniers, Han; Desmet, Gert

    2010-09-24

    We report on the possibility to perform HDC in micropillar array columns and the potential advantages of such a system. The HDC performance of a pillar array column with pillar diameter = 5 microm and an interpillar distance of 2.5 microm has been characterized using both a low MW tracer (FITC) and differently sized polystyrene bead samples (100, 200 and 500 nm). The reduced plate height curves that were obtained for the different investigated markers all overlapped very well, and attained a minimum value of about h(min)=0.3 (reduction based on the pillar diameter), corresponding to 1.6 microm in absolute value and giving good prospects for high efficiency separations. The obtained reduced retention time values were in fair agreement with that predicted by the Di Marzio and Guttman model for a flow between flat plates, using the minimal interpillar distance as characteristic interplate distance. Copyright 2010 Elsevier B.V. All rights reserved.

  13. Abutment height influences the effect of platform switching on peri-implant marginal bone loss.

    PubMed

    Galindo-Moreno, Pablo; León-Cano, Ana; Monje, Alberto; Ortega-Oller, Inmaculada; O'Valle, Francisco; Catena, Andrés

    2016-02-01

    The purpose was to radiographically analyze and compare the marginal bone loss (MBL) between implants with different mismatching distance and to study the influence of the prosthetic abutment height on the MBL in association with the related mismatching distances. This retrospective study included 108 patients in whom 228 implants were placed, 180 with diameter of 4.5 mm and 48 with diameter of 5 mm. All patients received OsseoSpeed™ implants with internal tapered conical connection (Denstply Implants). Different mismatching distances were obtained, given that all implants were loaded with the same uni-abutment type (Lilac; Denstply Implants). Data were gathered on age, gender, bone substratum, smoking habits, previous history of periodontitis, and prosthetic features. MBL was analyzed radiographically at 6 and 18 months post-loading. Mixed linear analysis of mesial and distal MBL values yielded significant effects of abutment, implant diameter, follow-up period, bone substratum, smoking, and abutment × time interaction. MBL was greater at 18 vs. 6 months, for short vs. long abutments, for grafted vs. pristine bone, for a heavier smoking habit, and for implants with a diameter of 5.0 vs. 4.5 mm. Greater mismatching does not minimize the MBL; abutment height, smoking habit, and bone substratum may play a role in the MBL over the short- and medium term. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Oligomeric structure and functional characterization of Caenorhabditis elegans Innexin-6 gap junction protein.

    PubMed

    Oshima, Atsunori; Matsuzawa, Tomohiro; Nishikawa, Kouki; Fujiyoshi, Yoshinori

    2013-04-12

    Innexin is the molecular component of invertebrate gap junctions. Here we successfully expressed and purified Caenorhabditis elegans innexin-6 (INX-6) gap junction channels and characterized the molecular dimensions and channel permeability using electron microscopy (EM) and microinjection of fluorescent dye tracers, respectively. Negative staining and thin-section EM of isolated INX-6 gap junction membranes revealed a loosely packed hexagonal lattice and a greater cross-sectional width than that of connexin26 and connexin43 (Cx43)-GFP. In gel filtration analysis, the elution profile of purified INX-6 channels in dodecyl maltoside solution exhibited a peak at ∼400 kDa that was shifted to ∼800 kDa in octyl glucose neopentyl glycol. We also obtained the class averages of purified INX-6 channels from these peak fractions by single particle analysis. The class average from the ∼800-kDa fraction showed features of the junction form with a longitudinal height of 220 Å, a channel diameter of 110 Å in the absence of detergent micelles, and an extracellular gap space of 60 Å, whereas the class averages from the ∼400-kDa fraction showed diameters of up to 140 Å in the presence of detergent micelles. These findings indicate that the purified INX-6 channels are predominantly hemichannels in dodecyl maltoside and docked junction channels in octyl glucose neopentyl glycol. Dye transfer experiments revealed that the INX-6-GFP-His channels are permeable to 3- and 10-kDa tracers, whereas no significant amounts of these tracers passed through the Cx43-GFP channels. Based on these findings, INX-6 channels have a larger overall structure and greater permeability than connexin channels.

  15. Oligomeric Structure and Functional Characterization of Caenorhabditis elegans Innexin-6 Gap Junction Protein*

    PubMed Central

    Oshima, Atsunori; Matsuzawa, Tomohiro; Nishikawa, Kouki; Fujiyoshi, Yoshinori

    2013-01-01

    Innexin is the molecular component of invertebrate gap junctions. Here we successfully expressed and purified Caenorhabditis elegans innexin-6 (INX-6) gap junction channels and characterized the molecular dimensions and channel permeability using electron microscopy (EM) and microinjection of fluorescent dye tracers, respectively. Negative staining and thin-section EM of isolated INX-6 gap junction membranes revealed a loosely packed hexagonal lattice and a greater cross-sectional width than that of connexin26 and connexin43 (Cx43)-GFP. In gel filtration analysis, the elution profile of purified INX-6 channels in dodecyl maltoside solution exhibited a peak at ∼400 kDa that was shifted to ∼800 kDa in octyl glucose neopentyl glycol. We also obtained the class averages of purified INX-6 channels from these peak fractions by single particle analysis. The class average from the ∼800-kDa fraction showed features of the junction form with a longitudinal height of 220 Å, a channel diameter of 110 Å in the absence of detergent micelles, and an extracellular gap space of 60 Å, whereas the class averages from the ∼400-kDa fraction showed diameters of up to 140 Å in the presence of detergent micelles. These findings indicate that the purified INX-6 channels are predominantly hemichannels in dodecyl maltoside and docked junction channels in octyl glucose neopentyl glycol. Dye transfer experiments revealed that the INX-6-GFP-His channels are permeable to 3- and 10-kDa tracers, whereas no significant amounts of these tracers passed through the Cx43-GFP channels. Based on these findings, INX-6 channels have a larger overall structure and greater permeability than connexin channels. PMID:23460640

  16. Comparison of pitot traverses taken at varying distances downstream of obstructions.

    PubMed

    Guffey, S E; Booth, D W

    1999-01-01

    This study determined the deviations between pitot traverses taken under "ideal" conditions--at least seven duct diameter's lengths (i.e., distance = 7D) from obstructions, elbows, junction fittings, and other disturbances to flows--with those taken downstream from commonplace disturbances. Two perpendicular 10-point, log-linear velocity pressure traverses were taken at various distances downstream of tested upstream conditions. Upstream conditions included a plain duct opening, a junction fitting, a single 90 degrees elbow, and two elbows rotated 90 degrees from each other into two orthogonal planes. Airflows determined from those values were compared with the values measured more than 40D downstream of the same obstructions under ideal conditions. The ideal measurements were taken on three traverse diameters in the same plane separated by 120 degrees in honed drawn-over-mandrel tubing. In all cases the pitot tubes were held in place by devices that effectively eliminated alignment errors and insertion depth errors. Duct velocities ranged from 1500 to 4500 ft/min. Results were surprisingly good if one employed two perpendicular traverses. When the averages of two perpendicular traverses was taken, deviations from ideal value were 6% or less even for traverses taken as close as 2D distance from the upstream disturbances. At 3D distance, deviations seldom exceeded 5%. With single diameter traverses, errors seldom exceeded 5% at 6D or more downstream from the disturbance. Interestingly, percentage deviations were about the same at high and low velocities. This study demonstrated that two perpendicular pitot traverses can be taken as close as 3D from these disturbances with acceptable (< or = 5%) deviations from measurements taken under ideal conditions.

  17. Increasing Fleet Readiness Through Improved Distance Support

    DTIC Science & Technology

    2013-03-01

    gis tic s D ata Pro ce ss  Tra ini ng  Da ta An aly ze  Da ta An...Format Fleet Maintenance Formatted Data /sData F.2.2 • ... Fleet Support Infrastructure Data ~ Formatted Trainin~ ata l Obtain and Format Fleet...system either by using a form or a spreadsheet F.2.2 Obtain Data from Fleet Recorded System Performance Data is downloaded from ship either manually

  18. Study of the filtration performance of a plain wave fabric filter using response surface methodology.

    PubMed

    Qian, Fuping; Wang, Haigang

    2010-04-15

    The gas-solid two-phase flows in the plain wave fabric filter were simulated by computational fluid dynamics (CFD) technology, and the warps and wefts of the fabric filter were made of filaments with different dimensions. The numerical solutions were carried out using commercial computational fluid dynamics (CFD) code Fluent 6.1. The filtration performances of the plain wave fabric filter with different geometry parameters and operating condition, including the horizontal distance, the vertical distance and the face velocity were calculated. The effects of geometry parameters and operating condition on filtration efficiency and pressure drop were studied using response surface methodology (RSM) by means of the statistical software (Minitab V14), and two second-order polynomial models were obtained with regard to the effect of the three factors as stated above. Moreover, the models were modified by dismissing the insignificant terms. The results show that the horizontal distance, vertical distance and the face velocity all play an important role in influencing the filtration efficiency and pressure drop of the plane wave fabric filters. The horizontal distance of 3.8 times the fiber diameter, the vertical distance of 4.0 times the fiber diameter and Reynolds number of 0.98 are found to be the optimal conditions to achieve the highest filtration efficiency at the same face velocity, while maintaining an acceptable pressure drop. 2009 Elsevier B.V. All rights reserved.

  19. Assessment of the effect of deviated nasal septum on the structure of nasal cavity.

    PubMed

    Wang, Junguo; Dou, Xin; Liu, Dingding; Song, Panpan; Qian, Xiaoyun; Wang, Shoulin; Gao, Xia

    2016-06-01

    The present study was aimed to investigate the effects of DNS on the structure of nasal cavity. The paranasal sinus coronal view CT of 108 patients with DNS and 129 hospitalized patients without DNS was retrospectively analyzed. The transverse diameter of nasal cavity (a), transverse diameter of nasal cavity and paranasal sinus (b), angle between maxillary and palatal bone, interalveolar distance, and maxillary rotation distance were measured. The ratio of a/b in experimental group was 0.367 ± 0.006 which was significantly (P = 0.0023) less than that in control group (0.391 ± 0.005). For the angle between maxillary and palatal bone, there was no significant difference found between DNS and control group for both right and left sides. The interalveolar distance was 40.75 mm in experimental group, and 38.8 mm in control (P = 0.0002). For the maxillary rotation distance, findings were considered as significant (P < 0.0001) in experimental group (11.25 mm) compared with control (10.1 mm). The present study demonstrates that long-term DNS affects the development of nasal cavity and paranasal sinus, as well as increases the interalveolar distance and maxillary rotation distance. These influences may be caused by the alteration of airflow inside the nasal cavities.

  20. Distance measurement based on light field geometry and ray tracing.

    PubMed

    Chen, Yanqin; Jin, Xin; Dai, Qionghai

    2017-01-09

    In this paper, we propose a geometric optical model to measure the distances of object planes in a light field image. The proposed geometric optical model is composed of two sub-models based on ray tracing: object space model and image space model. The two theoretic sub-models are derived on account of on-axis point light sources. In object space model, light rays propagate into the main lens and refract inside it following the refraction theorem. In image space model, light rays exit from emission positions on the main lens and subsequently impinge on the image sensor with different imaging diameters. The relationships between imaging diameters of objects and their corresponding emission positions on the main lens are investigated through utilizing refocusing and similar triangle principle. By combining the two sub-models together and tracing light rays back to the object space, the relationships between objects' imaging diameters and corresponding distances of object planes are figured out. The performance of the proposed geometric optical model is compared with existing approaches using different configurations of hand-held plenoptic 1.0 cameras and real experiments are conducted using a preliminary imaging system. Results demonstrate that the proposed model can outperform existing approaches in terms of accuracy and exhibits good performance at general imaging range.

  1. Arrays of quasi-hexagonally ordered silica nanopillars with independently controlled areal density, diameter and height gradients

    NASA Astrophysics Data System (ADS)

    Özdemir, Burcin; Huang, Wenting; Plettl, Alfred; Ziemann, Paul

    2015-03-01

    A consecutive fabrication approach of independently tailored gradients of the topographical parameters distance, diameter and height in arrays of well-ordered nanopillars on smooth SiO2-Si-wafers is presented. For this purpose, previously reported preparation techniques are further developed and combined. First, self-assembly of Au-salt loaded micelles by dip-coating with computer-controlled pulling-out velocities and subsequent hydrogen plasma treatment produce quasi-hexagonally ordered, 2-dimensional arrays of Au nanoparticles (NPs) with unidirectional variations of the interparticle distances along the pulling direction between 50-120 nm. Second, the distance (or areal density) gradient profile received in this way is superimposed with a diameter-controlled gradient profile of the NPs applying a selective photochemical growth technique. For demonstration, a 1D shutter is used for locally defined UV exposure times to prepare Au NP size gradients varying between 12 and 30 nm. Third, these double-gradient NP arrangements serve as etching masks in a following reactive ion etching step delivering arrays of nanopillars. For height gradient generation, the etching time is locally controlled by applying a shutter made from Si wafer piece. Due to the high flexibility of the etching process, the preparation route works on various materials such as cover slips, silicon, silicon oxide, silicon nitride and silicon carbide.

  2. Virtual reality training improves da Vinci performance: a prospective trial.

    PubMed

    Cho, Jae Sung; Hahn, Koo Yong; Kwak, Jung Myun; Kim, Jin; Baek, Se Jin; Shin, Jae Won; Kim, Seon Hahn

    2013-12-01

    The DV-Trainer™ (a virtual reality [VR] simulator) (Mimic Technologies, Inc., Seattle, WA) is one of several different robotic surgical training methods. We designed a prospective study to determine whether VR training could improve da Vinci(®) Surgical System (Intuitive Surgical, Inc., Sunnyvale, CA) performance. Surgeons (n=12) were enrolled using a randomized protocol. Groups 1 (VR training) and 2 (control) participated in VR and da Vinci exercises. Participants' time and moving distance were combined to determine a composite score: VR index=1000/(time×moving distance). The da Vinci exercises included needle control and suturing. Procedure time and error were measured. A composite index (DV index) was computed and used to measure da Vinci competency. After the initial trial with both the VR and da Vinci exercises, only Group 1 was trained with the VR simulator following our institutional curriculum for 3 weeks. All members of both groups then participated in the second trial of the VR and da Vinci exercises and were scored in the same way as in the initial trial. In the initial trial, there was no difference in the VR index (Group 1 versus Group 2, 8.9 ± 3.3 versus 9.4 ± 3.7; P=.832) and the DV index (Group 1 versus Group 2, 3.85 ± 0.73 versus 3.66 ± 0.65; P=.584) scores between the two groups. At the second time point, Group 1 showed increased VR index scores in comparison with Group 2 (19.3 ± 4.5 versus 9.7 ± 4.1, respectively; P=.001) and improved da Vinci performance skills as measured by the DV index (5.80 ± 1.13 versus 4.05 ± 1.03, respectively; P=.028) and by suturing time (7.1 ± 1.54 minutes versus 10.55 ± 1.93 minutes, respectively; P=.018). We found that VR simulator training can improve da Vinci performance. VR practice can result in an early plateau in the learning curve for robotic practice under controlled circumstances.

  3. Morphologic characterization of the patent ductus arteriosus in the premature infant and the choice of transcatheter occlusion device.

    PubMed

    Philip, Ranjit; Waller, B Rush; Agrawal, Vijaykumar; Wright, Dena; Arevalo, Alejandro; Zurakowski, David; Sathanandam, Shyam

    2016-02-01

    The aim of this study was to describe and differentiate the morphology of patent ductus arteriosus (PDA) seen in children born prematurely from other PDA types. PDAs are currently classified as types A-E using the Krichenko's classification. Children born prematurely with a PDA morphology that did not fit this classification were described as Type F PDA. A review of 100 consecutive children who underwent transcatheter device closure of PDA was performed. The diameter and length (L) of the PDA and the device diameter (D) were indexed to the descending aorta (DA) diameter. Comparison of 26 Type F PDAs was performed against, 29 Type A, 7 Type C and 32 Type E PDAs. Children with Type F PDAs (median 27.5 weeks gestation) were younger during the device occlusion compared with types A, C, and E (median age: 6 vs. 32, 11, and 42 months; P = 0.002). Type F PDAs were longer and larger, requiring a relatively large device for occlusion than types A, C, and E (Mean L/DA: 1.88 vs. 0.9, 1.21, and 0.89, P ≤ 0.01 and Mean D/DA: 1.04 vs. 0.46, 0.87, and 0.34, P ≤0.01). The Amplatzer vascular plug-II (AVP-II) was preferred for occlusion of Type F PDAs (85%; P <0.001). Children born prematurely have relatively larger and longer PDAs. These "fetal type PDAs" are best classified separately. We propose to classify them as Type F PDAs to add to types A-E currently in use. The AVP-II was effective in occluding Type F PDAs. © 2015 Wiley Periodicals, Inc.

  4. New measurement of the period for the 4th ULX pulsar - the supernova impostor SN2010da in NGC 300

    NASA Astrophysics Data System (ADS)

    Grebenev, S. A.; Mereminskiy, I. A.

    2018-01-01

    Following the discovery (Atel #11158) of the new (fourth) ULX pulsar (in the peculiar supergiant X-ray binary known as the supernova impostor SN 2010da located in NGC 300, at a distance of 1.86 Mpc) we note that SWIFT/XRT observed this galaxy again on April 16, 2017, and detected the source still in a bright X-ray state.

  5. Maximizing coupling strength of magnetically anchored surgical instruments: how thick can we go?

    PubMed

    Best, Sara L; Bergs, Richard; Gedeon, Makram; Paramo, Juan; Fernandez, Raul; Cadeddu, Jeffrey A; Scott, Daniel J

    2011-01-01

    The Magnetic Anchoring and Guidance System (MAGS) includes an external magnet that controls intra-abdominal surgical instruments via magnetic attraction forces. We have performed NOTES (Natural Orifice Transluminal Endoscopic Surgery) and LESS (Laparoendoscopic Single Site) procedures using MAGS instruments in porcine models with up to 2.5-cm-thick abdominal walls, but this distance may not be sufficient in some humans. The purpose of this study was to determine the maximal abdominal wall thickness for which the current MAGS platform is suitable. Successive iterations of prototype instruments were developed; those evaluated in this study include external (134-583 g, 38-61 mm diameter) and internal (8-39 g, 10-22 mm diameter) components using various grades, diameters, thicknesses, and stacking/shielding/focusing configurations of permanent Neodymium-iron-boron (NdFeB) magnets. Nine configurations were tested for coupling strength across distances of 0.1-10 cm. The force-distance tests across an air medium were conducted at 0.5-mm increments using a robotic arm fitted with a force sensor. A minimum theoretical instrument drop-off (decoupling) threshold was defined as the separation distance at which force decreased below the weight of the heaviest internal component (39 g). Magnetic attraction forces decreased exponentially over distance. For the nine configurations tested, the average forces were 3,334 ± 1,239 gf at 0.1 cm, 158 ± 98 gf at 2.5 cm, and 8.7 ± 12 gf at 5 cm; the drop-off threshold was 3.64 ± 0.8 cm. The larger stacking configurations and magnets yielded up to a 592% increase in attraction force at 2.5 cm and extended the drop-off threshold distance by up to 107% over single-stack anchors. For the strongest configuration, coupling force ranged from 5,337 gf at 0.1 cm to 0 gf at 6.95 cm and yielded a drop-off threshold distance of 4.78 cm. This study suggests that the strongest configuration of currently available MAGS instruments is suitable for clinically relevant abdominal wall thicknesses. Further platform development and optimization are warranted.

  6. Size of Douglas-fir trees in relation to distance from a mixed red alder - Douglas-fir stand

    Treesearch

    R.E. Miller; D.L. Reukema; T.A. Max

    1993-01-01

    Variation in diameter, height, and stem volume of 57-year-old Douglas-fir(Pseudotsuga menziesii var. menziesii (Mirb.) Franco) was related to distance of these trees from a 27 m wide strip in the same Douglas-fir plantation that had been interplanted with red alder (Alnus rubra Bong.). Within the...

  7. What You See Is What You Get: Investigations with a View Tube

    ERIC Educational Resources Information Center

    Obara, Samuel

    2009-01-01

    This paper presents an investigation by pre-service secondary school teachers in a geometry class of the relationship between the perpendicular distance from the eyeball to the wall (x) and the viewable vertical distance on the wall (y) using a view tube of constant length and diameter. In undertaking the investigation, students used tabular and…

  8. Angular and radial dependence of the energy response factor for LIF-TLD micro-rods in 125L permanent implant source.

    PubMed

    Mobit, Paul; Badragan, Iulian

    2006-01-01

    EGSnrc Monte Carlo simulations were used to calculate the angular and radial dependence of the energy response factor for LiF-thermoluminescence dosemeters (TLDs) irradiated with a commercially available (125)I permanent brachytherapy source. The LiF-TLDs were modelled as cylindrical micro-rods of length 6 mm and with diameters of 1 mm and 5 mm. The results show that for a LiF-TLD micro-rod of 1 mm diameter, the energy response relative to (60)Co gamma rays is 1.406 +/- 0.3% for a polar angle of 90 degrees and radial distance of 1.0 cm. When the diameter of the micro-rod is increased from 1 to 5 mm, the energy response decreases to 1.32 +/- 0.3% at the same point. The variation with position of the energy response factor is not >5% in a 6 cm x 6 cm x 6 cm calculation grid for the 5 mm diameter micro-rod. The results show that there is a change in the photon spectrum with angle and radial distance, which causes the variation of the energy response.

  9. PMMA/PS coaxial electrospinning: a statistical analysis on processing parameters

    NASA Astrophysics Data System (ADS)

    Rahmani, Shahrzad; Arefazar, Ahmad; Latifi, Masoud

    2017-08-01

    Coaxial electrospinning, as a versatile method for producing core-shell fibers, is known to be very sensitive to two classes of influential factors including material and processing parameters. Although coaxial electrospinning has been the focus of many studies, the effects of processing parameters on the outcomes of this method have not yet been well investigated. A good knowledge of the impacts of processing parameters and their interactions on coaxial electrospinning can make it possible to better control and optimize this process. Hence, in this study, the statistical technique of response surface method (RSM) using the design of experiments on four processing factors of voltage, distance, core and shell flow rates was applied. Transmission electron microscopy (TEM), scanning electron microscopy (SEM), oil immersion and Fluorescent microscopy were used to characterize fiber morphology. The core and shell diameters of fibers were measured and the effects of all factors and their interactions were discussed. Two polynomial models with acceptable R-squares were proposed to describe the core and shell diameters as functions of the processing parameters. Voltage and distance were recognized as the most significant and influential factors on shell diameter, while core diameter was mainly under the influence of core and shell flow rates besides the voltage.

  10. Ichnological evidence of jökulhlaup deposit recolonization from the Touchet Beds, Mabton, WA, USA

    NASA Astrophysics Data System (ADS)

    MacEachern, James A.; Roberts, Michael C.

    2013-01-01

    The late Wisconsinan Touchet Beds section at Mabton, Washington reveals at least seven stacked jökulhlaup deposits, five showing evidence of post-flood recolonization by vertebrates. Tracemakers are attributed to voles or pocket mice (1-3 cm diameter burrows) and pocket gophers or ground squirrels (3-6 cm diameter burrows). The Mount St. Helens S tephra deposited between flood beds contains the invertebrate-generated burrows Naktodemasis and Macanopsis. Estimates of times between floods are based on natal dispersal distances of the likely vertebrate tracemakers (30-50 m median distances; 127-525 m maximum distances) from upland areas containing surviving populations to the Mabton area, a distance of about 7.9 km. Tetrapods would have required at least two to three decades to recolonize these flood beds, based on maximum dispersal distances. Invertebrate recolonization was limited by secondary succession and estimated at only a few years to a decade. These ichnological data support multiple floods from failure of the ice dam at glacial Lake Missoula, separated by hiatal surfaces on the order of decades in duration. Ichnological recolonization times are consistent with published estimates of refill times for glacial Lake Missoula, and complement the other field evidence that points to repeated, autogenically induced flood discharge.

  11. Experimental Evaluation of the Heat Sink Effect in Hepatic Microwave Ablation.

    PubMed

    Ringe, Kristina I; Lutat, Carolin; Rieder, Christian; Schenk, Andrea; Wacker, Frank; Raatschen, Hans-Juergen

    2015-01-01

    To demonstrate and quantify the heat sink effect in hepatic microwave ablation (MWA) in a standardized ex vivo model, and to analyze the influence of vessel distance and blood flow on lesion volume and shape. 108 ex vivo MWA procedures were performed in freshly harvested pig livers. Antennas were inserted parallel to non-perfused and perfused (700,1400 ml/min) glass tubes (diameter 5mm) at different distances (10, 15, 20mm). Ablation zones (radius, area) were analyzed and compared (Kruskal-Wallis Test, Dunn's multiple comparison Test). Temperature changes adjacent to the tubes were measured throughout the ablation cycle. Maximum temperature decreased significantly with increasing flow and distance (p<0.05). Compared to non-perfused tubes, ablation zones were significantly deformed by perfused tubes within 15 mm distance to the antenna (p<0.05). At a flow rate of 700 ml/min ablation zone radius was reduced to 37.2% and 80.1% at 10 and 15 mm tube distance, respectively; ablation zone area was reduced to 50.5% and 89.7%, respectively. Significant changes of ablation zones were demonstrated in a pig liver model. Considerable heat sink effect was observed within a diameter of 15 mm around simulated vessels, dependent on flow rate. This has to be taken into account when ablating liver lesions close to vessels.

  12. Maxillary tridimensional changes after slow expansion with leaf expander in a sample of growing patients: a pilot study.

    PubMed

    Lanteri, V; Gianolio, A; Gualandi, G; Beretta, M

    2018-03-01

    The aim of this study is to evaluate the dento-alveolar effects of slow maxillary expansion using the Leaf Expander in a sample of growing patients with maxillary transverse deficiency, unilateral cross bite and mandibular shift. The study included 10 patients, 3 male and 7 female (mean age 7.5 + 7 months), treated with Leaf Expander anchored on the upper deciduous teeth. Digital models were obtained by a lab scan of the pvs impressions at the beginning of the therapy (T1) and at the removal of the palatal expander (T2). Five parameters were measured: 1) the distance between the first upper permanent molars; 2) the distance between the upper second deciduous molars; 3) the distance between the upper canine cusps 4) the distance between the first lower permanent molars; 5) the distance of the lower canine cusps. In all patients complete correction of posterior crossbite was achieved on average in 4 months, with a spontaneous expansion of the upper first permanent molars. Significant increases in the dento-alveolar transversal diameters were obtained. Increases were also observed in the anterior mandibular arch diameter (+ 1 mm). These findings suggest that slow maxillary expansion using Leaf Expander appliance could be a reasonable alternative to conventional maxillary expansion therapy in the early mixed dentition.

  13. Interosseous membrane window size for tibialis posterior tendon transfer-Geometrical and MRI analysis.

    PubMed

    Wagner, Pablo; Ortiz, Cristian; Vela, Omar; Arias, Paul; Zanolli, Diego; Wagner, Emilio

    2016-09-01

    Tibialis posterior (TP) tendon transfer through the interosseous membrane is commonly performed in Charcot-Marie-Tooth disease. In order to avoid entrapment of this tendon, no clear recommendation relative to the interosseous membrane (IOM) incision size has been made. Analyze the TP size at the transfer level and therefore determine the most adequate IOM window size to avoid muscle entrapment. Eleven lower extremity magnetic resonances were analyzed. TP muscle measurements were made in axial views, obtaining the medial-lateral and antero-posterior diameter at various distances from the medial malleolus tip. The distance from the posterior to anterior compartment was also measured. These measurements were applied to a mathematical model to predict the IOM window size necessary to allow an ample TP passage in an oblique direction. The average tendon diameter (confidence-interval) at 15cm proximal to the medial malleolus tip was 19.47mm (17.47-21.48). The deep posterior compartment to anterior compartment distance was 10.97mm (9.03-12.90). Using a mathematical model, the estimated IOM window size ranges from 4.2 to 4.9cm. The IOM window size is of utmost importance in trans-membrane TP transfers, given that if equal or smaller than the transposed tendon oblique diameter, a high entrapment risk exists. A membrane window of 5cm or 2.5 times the size of the tendon diameter should be performed in order to theoretically diminish this complication. Copyright © 2015 European Foot and Ankle Society. Published by Elsevier Ltd. All rights reserved.

  14. Preparation and characterization of kefiran electrospun nanofibers.

    PubMed

    Esnaashari, Seyedeh Sara; Rezaei, Sasan; Mirzaei, Esmaeil; Afshari, Hamed; Rezayat, Seyed Mahdi; Faridi-Majidi, Reza

    2014-09-01

    In this study, we report the first successful production of kefiran nanofibers through electrospinning process using distilled water as solvent. For this purpose, kefiran was extracted from cultured kefir grains, and homogenous kefiran solutions with different concentrations were prepared and then electrospun to obtain uniform nanofibers. The effect of main process parameters, including applied voltage, tip-to-collector distance, and feeding rate, on diameter and morphology of produced nanofibers, was studied. Scanning electron microscopy (SEM) and attenuated total reflectance Fourier transform infrared (ATR-FTIR) spectroscopy were used to characterize electrospun mats. Rheological behavior of the kefiran solution was evaluated via a cone and plate rheometer too. The results exhibited that diameter of kefiran nanofibers increased with increasing polymer concentration, applied voltage, and polymer feeding rate, while tip-to-collector distance did not have significant effect on nanofiber diameter. ATR-FTIR spectra showed that kefiran has maintained its molecular structure during electrospinning process. Flow curves also demonstrated shear thinning behavior for kefiran solutions. Copyright © 2014 Elsevier B.V. All rights reserved.

  15. Dust Cloud Modeling and Propagation Effects for Radar and Communications Codes

    DTIC Science & Technology

    1978-11-01

    particles can be described by a power law probabi 1it Y d i st r i ut i on with a power exponent of 4. Four is a typical value for dust particlIs from...loose unconsolidated soils such as desert alluviun, blust ,eera ted from a nuclear cratering explosion in rock and cohes ive soil s haN pO,,e r exponent ...da p = power law exponent amin = minimum particle diameter in the distribution (cm) a = maximum particle diameter in the distribution (cm).max The log

  16. Volumes and intrinsic diameters of hypersurfaces

    NASA Astrophysics Data System (ADS)

    Paeng, Seong-Hun

    2015-09-01

    We estimate the volume and the intrinsic diameter of a hypersurface M with geometric information of a hypersurface which is parallel to M at distance T. It can be applied to the Riemannian Penrose inequality to obtain a lower bound of the total mass of a spacetime. Also it can be used to obtain upper bounds of the volume and the intrinsic diameter of the celestial r-sphere without a lower bound of the sectional curvature. We extend our results to metric-measure spaces by using the Bakry-Emery Ricci tensor.

  17. Predicting performance for ecological restoration: A case study using Spartina altemiflora

    USGS Publications Warehouse

    Travis, S.E.; Grace, J.B.

    2010-01-01

    The success of population-based ecological restoration relies on the growth and reproductive performance of selected donor materials, whether consisting of whole plants or seed. Accurately predicting performance requires an understanding of a variety of underlying processes, particularly gene flow and selection, which can be measured, at least in part, using surrogates such as neutral marker genetic distances and simple latitudinal effects. Here we apply a structural equation modeling approach to understanding and predicting performance in a widespread salt marsh grass, Spartina alterniflora, commonly used for ecological restoration throughout its native range in North America. We collected source materials from throughout this range, consisting of eight clones each from 23 populations, for transplantation to a common garden site in coastal Louisiana and monitored their performance. We modeled performance as a latent process described by multiple indicator variables (e.g., clone diameter, stem number) and estimated direct and indirect influences of geographic and genetic distances on performance. Genetic distances were determined by comparison of neutral molecular markers with those from a local population at the common garden site. Geographic distance metrics included dispersal distance (the minimum distance over water between donor and experimental sites) and latitude. Model results indicate direct effects of genetic distance and latitude on performance variation among the donor sites. Standardized effect strengths indicate that performance was roughly twice as sensitive to variation in genetic distance as to latitudinal variation. Dispersal distance had an indirect influence on performance through effects on genetic distance, indicating a typical pattern of genetic isolation by distance. Latitude also had an indirect effect on genetic distance through its linear relationship with dispersal distance. Three performance indicators had significant loadings on performance alone (mean clone diameter, mean number of stems, mean number of inflorescences), while the performance indicators mean stem height and mean stem width were also influenced by latitude. We suggest that dispersal distance and latitude should provide an adequate means of predicting performance in future S. alterniflora restorations and propose a maximum sampling distance of 300 km (holding latitude constant) to avoid the sampling of inappropriate ecotypes. ?? 2010 by the Ecological Society of America.

  18. Sex Determination by Biometry of Anterior Features of Human Hip Bones in South Indian Population.

    PubMed

    Rajasekhar, Sssn; Vasudha, T K; Aravindhan, K

    2017-06-01

    Sex determination is the first step in establishing the identity of skeletal remains. Many studies included biometry of posterior features of hip bone. Very few studies are reported involving the biometry of anterior features of the hip bone. Anterior features of hip bone are important especially, if there is damage to the posterior features of hip bone in cases involving deliberate disfigurement of the body to resist identification of the crime in medicolegal cases. The present study was done to evaluate the effectiveness of anterior border parameters of the hip bone for prediction of sex using discriminant function analysis in South Indian population. A total of 206 dry bones were used (121 male and 85 female) and parameters like the distance between pubic tubercle and anterior rim of acetabulum, vertical acetabular diameter, transverse acetabular diameter, and the distance between pubic tubercle to highest point on the iliopubic eminence were measured using Vernier calipers. Normally distributed variables were compared using Students t-test to analyse the significance. There was significant difference between the male and female hip bones of the observed variables with p-value less than 0.05. In parameters like the distance between pubic tubercle to anterior rim of acetabulum and distance between the highest points on iliopubic eminence to pubic tubercle; the values were more in female when compared to males. In parameters like vertical and transverse acetabular diameters; the values in males were more when compared to females. These parameters of hip bone can be utilised for sex determination in South Indian population.

  19. Controlled tether extends satellite's orbital range

    NASA Astrophysics Data System (ADS)

    Wigotsky, V.

    1984-06-01

    A low orbit satellite tethered to the Space Shuttle Orbiter's cargo bay would be able to conduct upper atmosphere experiments without fear of orbit deterioration. NASA has in light of this initiated a Tethered Satellite System program aimed at the 1987 deployment of a 1,100-lb, 5 ft-diameter satellite to a distance of 6-12 miles from the Space Shuttle on a Kevlar tether. The distance of the fully developed system will be 62 miles, representing an altitude of 80 miles above the earth. Tether diameters under consideration are in the 0.065-0.1 inch range. The satellite control system will consist of a reel drive, a deployment boom, and a boom-mounted tether control, in order to vary tether tension during gravity gradient changes.

  20. Unified interpretation of exciplex formation and marcus electron transfer on the basis of two-dimensional free energy surfaces.

    PubMed

    Murata, Shigeo; Tachiya, M

    2007-09-27

    The mechanism of exciplex formation proposed in a previous paper has been refined to show how exciplex formation and Marcus electron transfer (ET) in fluorescence quenching are related to each other. This was done by making simple calculations of the free energies of the initial (DA*) and final (D+A-) states of ET. First it was shown that the decrease in D-A distance can induce intermolecular ET even in nonpolar solvents where solvent orientational polarization is absent, and that it leads to exciplex formation. This is consistent with experimental results that exciplex is most often observed in nonpolar solvents. The calculation was then extended to ET in polar solvents where the free energies are functions of both D-A distance and solvent orientational polarization. This enabled us to discuss both exciplex formation and Marcus ET in the same D-A pair and solvent on the basis of 2-dimensional free energy surfaces. The surfaces contain more information about the rates of these reactions, the mechanism of fluorescence quenching by ET, etc., than simple reaction schemes. By changing the parameters such as the free energy change of reaction, solvent dielectric constants, etc., one can construct the free energy surfaces for various systems. The effects of free energy change of reaction and of solvent polarity on the mechanism and relative importance of exciplex formation and Marcus ET in fluorescence quenching can be well explained. The free energy surface will also be useful for discussion of other phenomena related to ET reactions.

  1. Astronomy at School: Measurements of the Earth-Moon Distance. (Spanish Title: Astronomía en la Escuela: Medición de la Distancia Tierra-Luna.) Astronomia na Escola: Medida da Distância Terra-Lua

    NASA Astrophysics Data System (ADS)

    Paolantonio, Santiago; Pintado, Olga I.

    2006-12-01

    The aim of this project is to approach High School students to Science. We propose to measure the Earth-Moon distance using the parallax. The observation and measurements techniques and all the calculations needed are described in this paper. The results obtained in a test experience realized during 2003 are presented. This test shows that this is a feasible project and also shows which things needed to be improved. Se plantea la propuesta de un proyecto educativo dirigido al Nivel Medio de enseñanza, consistente en la determinación de la distancia Tierra - Luna por paralaje. Se describen las técnicas de observación, mediciones y cálculos. Se proporcionan a continuación los resultados obtenidos en la experiencia piloto realizada en el 2003, la que permitió comprobar la factibilidad de llevar a cabo la propuesta, así como perfeccionar los diferentes aspectos involucrados en la misma. Propomos neste trabalho um projeto educativo dirigido ao Ensino Médio que consiste na determinação da distância Terra-Lua pelo efeito da paralaxe. As técnicas de observação, medidas e cálculos auxiliares são descritos, e os resultados obtidos numa experiência-teste realizada no ano de 2003 apresentados. Este último teste permitiu comprovar a viabilidade de execução da proposta e aperfeiçoar diversos aspectos da mesma.

  2. Photoacoustic-based approach to surgical guidance performed with and without a da Vinci robot

    NASA Astrophysics Data System (ADS)

    Gandhi, Neeraj; Allard, Margaret; Kim, Sungmin; Kazanzides, Peter; Lediju Bell, Muyinatu A.

    2017-12-01

    Death and paralysis are significant risks of modern surgeries, caused by injury to blood vessels and nerves hidden by bone and other tissue. We propose an approach to surgical guidance that relies on photoacoustic (PA) imaging to determine the separation between these critical anatomical features and to assess the extent of safety zones during surgical procedures. Images were acquired as an optical fiber was swept across vessel-mimicking targets, in the absence and presence of teleoperation with a research da Vinci Surgical System. Vessel separation distances were measured directly from PA images. Vessel positions were additionally recorded based on the fiber position (calculated from the da Vinci robot kinematics) that corresponded to an observed PA signal, and these recordings were used to indirectly measure vessel separation distances. Amplitude- and coherence-based beamforming were used to estimate vessel separations, resulting in 0.52- to 0.56-mm mean absolute errors, 0.66- to 0.71-mm root-mean-square errors, and 65% to 68% more accuracy compared to fiber position measurements obtained through the da Vinci robot kinematics. Similar accuracy was achieved in the presence of up to 4.5-mm-thick ex vivo tissue. Results indicate that PA image-based measurements of the separation among anatomical landmarks could be a viable method for real-time path planning in multiple interventional PA applications.

  3. Diameter growth models using FIA data from the Northeastern, Southern, and North Central Research Stations

    Treesearch

    Veronica C. Lessard; Ronald E. McRoberts; Margaret R. Holdaway

    2000-01-01

    Nonlinear, individual-tree, distance-independent annual diameter growth models are presented for species in two ecoregions defined by R.G. Bailey in the northern Lake States and in parts of the central and southern regions of the U.S. The models were calibrated using Forest Inventory and Analysis (FIA) data from undisturbed plots on land classified as timberland across...

  4. The clustering of galaxies in the completed SDSS-III Baryon Oscillation Spectroscopic Survey: theoretical systematics and Baryon Acoustic Oscillations in the galaxy correlation function

    NASA Astrophysics Data System (ADS)

    Vargas-Magaña, Mariana; Ho, Shirley; Cuesta, Antonio J.; O'Connell, Ross; Ross, Ashley J.; Eisenstein, Daniel J.; Percival, Will J.; Grieb, Jan Niklas; Sánchez, Ariel G.; Tinker, Jeremy L.; Tojeiro, Rita; Beutler, Florian; Chuang, Chia-Hsun; Kitaura, Francisco-Shu; Prada, Francisco; Rodríguez-Torres, Sergio A.; Rossi, Graziano; Seo, Hee-Jong; Brownstein, Joel R.; Olmstead, Matthew; Thomas, Daniel

    2018-06-01

    We investigate the potential sources of theoretical systematics in the anisotropic Baryon Acoustic Oscillation (BAO) distance scale measurements from the clustering of galaxies in configuration space using the final Data Release (DR12) of the Baryon Oscillation Spectroscopic Survey (BOSS). We perform a detailed study of the impact on BAO measurements from choices in the methodology such as fiducial cosmology, clustering estimators, random catalogues, fitting templates, and covariance matrices. The theoretical systematic uncertainties in BAO parameters are found to be 0.002 in the isotropic dilation α and 0.003 in the quadrupolar dilation ɛ. The leading source of systematic uncertainty is related to the reconstruction techniques. Theoretical uncertainties are sub-dominant compared with the statistical uncertainties for BOSS survey, accounting 0.2σstat for α and 0.25σstat for ɛ (σα, stat ˜ 0.010 and σɛ, stat ˜ 0.012, respectively). We also present BAO-only distance scale constraints from the anisotropic analysis of the correlation function. Our constraints on the angular diameter distance DA(z) and the Hubble parameter H(z), including both statistical and theoretical systematic uncertainties, are 1.5 per cent and 2.8 per cent at zeff = 0.38, 1.4 per cent and 2.4 per cent at zeff = 0.51, and 1.7 per cent and 2.6 per cent at zeff = 0.61. This paper is part of a set that analyses the final galaxy clustering data set from BOSS. The measurements and likelihoods presented here are cross-checked with other BAO analysis in Alam et al. The systematic error budget concerning the methodology on post-reconstruction BAO analysis presented here is used in Alam et al. to produce the final cosmological constraints from BOSS.

  5. A combined NLP-differential evolution algorithm approach for the optimization of looped water distribution systems

    NASA Astrophysics Data System (ADS)

    Zheng, Feifei; Simpson, Angus R.; Zecchin, Aaron C.

    2011-08-01

    This paper proposes a novel optimization approach for the least cost design of looped water distribution systems (WDSs). Three distinct steps are involved in the proposed optimization approach. In the first step, the shortest-distance tree within the looped network is identified using the Dijkstra graph theory algorithm, for which an extension is proposed to find the shortest-distance tree for multisource WDSs. In the second step, a nonlinear programming (NLP) solver is employed to optimize the pipe diameters for the shortest-distance tree (chords of the shortest-distance tree are allocated the minimum allowable pipe sizes). Finally, in the third step, the original looped water network is optimized using a differential evolution (DE) algorithm seeded with diameters in the proximity of the continuous pipe sizes obtained in step two. As such, the proposed optimization approach combines the traditional deterministic optimization technique of NLP with the emerging evolutionary algorithm DE via the proposed network decomposition. The proposed methodology has been tested on four looped WDSs with the number of decision variables ranging from 21 to 454. Results obtained show the proposed approach is able to find optimal solutions with significantly less computational effort than other optimization techniques.

  6. Revisiting the Distance Duality Relation using a non-parametric regression method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rana, Akshay; Mahajan, Shobhit; Mukherjee, Amitabha

    2016-07-01

    The interdependence of luminosity distance, D {sub L} and angular diameter distance, D {sub A} given by the distance duality relation (DDR) is very significant in observational cosmology. It is very closely tied with the temperature-redshift relation of Cosmic Microwave Background (CMB) radiation. Any deviation from η( z )≡ D {sub L} / D {sub A} (1+ z ){sup 2} =1 indicates a possible emergence of new physics. Our aim in this work is to check the consistency of these relations using a non-parametric regression method namely, LOESS with SIMEX. This technique avoids dependency on the cosmological model and worksmore » with a minimal set of assumptions. Further, to analyze the efficiency of the methodology, we simulate a dataset of 020 points of η ( z ) data based on a phenomenological model η( z )= (1+ z ){sup ε}. The error on the simulated data points is obtained by using the temperature of CMB radiation at various redshifts. For testing the distance duality relation, we use the JLA SNe Ia data for luminosity distances, while the angular diameter distances are obtained from radio galaxies datasets. Since the DDR is linked with CMB temperature-redshift relation, therefore we also use the CMB temperature data to reconstruct η ( z ). It is important to note that with CMB data, we are able to study the evolution of DDR upto a very high redshift z = 2.418. In this analysis, we find no evidence of deviation from η=1 within a 1σ region in the entire redshift range used in this analysis (0 < z ≤ 2.418).« less

  7. Polyethyleneglycol diacrylate hydrogels with plasmonic gold nanospheres incorporated via functional group optimization

    NASA Astrophysics Data System (ADS)

    Ponnuvelu, Dinesh Veeran; Kim, Seokbeom; Lee, Jungchul

    2017-12-01

    We present a facile method for the preparation of polyethyleneglycol diacrylate (PEG-DA) hydrogels with plasmonic gold (Au) nanospheres incorporated for various biological and chemical sensing applications. Plasmonic Au nanospheres were prepared ex situ using the standard citrate reduction method with an average diameter of 3.5 nm and a standard deviation of 0.5 nm, and evaluated for their surface functionalization process intended for uniform dispersion in polymer matrices. UV-Visible spectroscopy reveals the existence of plasmonic properties for pristine Au nanospheres, functionalized Au nanospheres, and PEG-DA with uniformly dispersed functionalized Au nanospheres (hybrid Au/PEG-DA hydrogels). Hybrid Au/PEG-DA hydrogels examined by using Fourier transform infra-red spectroscopy (FT-IR) exhibit the characteristic bands at 1635, 1732 and 2882 cm-1 corresponding to reaction products of OH- originating from oxidized product of citrate, -C=O stretching from ester bond, and C-H stretching of PEG-DA, respectively. Thermal studies of hybrid Au/PEG-DA hydrogels show three-stage decomposition with their stabilities up to 500 °C. Optical properties and thermal stabilities associated with the uniform dispersion of Au nanospheres within hydrogels reported herein will facilitate various biological and chemical sensing applications.

  8. Annular ring zoom system using two positive axicons

    NASA Astrophysics Data System (ADS)

    Dickey, Fred M.; Conner, Jacob D.

    2011-10-01

    The production of an annular ring of light with a variable diameter has applications in laser material processing and machining, particle manipulation, and corneal surgery. This can readily be accomplished using a positive and negative axicon pair. However, negative axicons are very expensive and difficult to obtain with small diameters. In this paper, we present a design of an annular ring zoom system using two positive axicons. One axicon is placed a distance before a primary lens that is greater than some prescribed minimum, and the second axicon is placed after the primary lens. The position of the second axicon determines the ring diameter. The ring diameter can be zoomed from some maximum design size to a zero diameter ring (spot). Experimental results from a developmental system will be presented.

  9. The entrainment rate for a row of turbulent jets. M.S. Thesis Final Report

    NASA Technical Reports Server (NTRS)

    Gordon, Eliott B.; Greber, Isaac

    1990-01-01

    Entrainment rates for a row of isothermal circular air jets issuing into a quiescent environment are found by integrating velocity distributions measured by a linearized hot-wire anemometer. Jet spacing to jet diameter ratios of 2.5, 5, 10, and 20 are studied at jet Reynold's numbers ranging from 5110 to 12070. Velocity distributions are determined at regular downstream intervals at axial distances equal to 16.4 to 164 jet diameters from the jet source. The entrainment rates for the four spacing configurations vary monotonically with increasing spacing/diameter between the limiting case of the slot jet entrainment rate (where the jet spacing to diameter ratio is zero) and the circular jet entrainment rate (in which the spacing to diameter ratio is infinity).

  10. Experimental study of cryogen spray properties for application in dermatologic laser surgery.

    PubMed

    Aguilar, Guillermo; Majaron, Boris; Karapetian, Emil; Lavernia, Enrique J; Nelson, J Stuart

    2003-07-01

    Cryogenic sprays are used for cooling human skin during laser dermatologic surgery. In this paper, six straight-tube nozzles are characterized by photographs of cryogenic spray shapes, as well as measurements of average droplet diameter, velocity, and temperature. A single-droplet evaporation model to predict average spray droplet diameter and temperature is tested using the experimental data presented here. The results show two distinct spray patterns--sprays for 1.4-mm-diameter nozzles (wide nozzles) show significantly larger average droplet diameters and higher temperatures as a function of distance from the nozzle compared with those for 0.5-0.8-mm-diameter nozzles (narrow nozzles). These results complement and support previously reported studies, indicating that wide nozzles induce more efficient heat extraction than the narrow nozzles.

  11. [Analysis of normal pelvis morphometry of modern Chinese southern Han female and its correlation with age].

    PubMed

    Liu, Ping; Yu, Yan-Hong; Chen, Chun-Lin; Tang, Yi-Xin; Wang, Li; Mao, Dong-Rui; Xu, Yi-Kai; Chen, Lan

    2013-07-01

    To analyze the normal pelvis morphometry of Chinese southern Han female and its correlation with age. From August 2009 to September 2011, 289 Han nationality females who received pelvis CT scan at Nanfang Hospital of Southern Medical University were eligible for the study. Their mean age was 43.5 years, with normal body development and no pelvic abnormality. The patients were divided into 3 age groups: 25 to 40 (n = 109), 41 to 50 (n = 115), and >50 years (n = 65). After constructing a three-dimensional digital model of the pelvis, the following parameters were measured, including transverse inlet diameter, posterior sagittal diameter of pelvic inlet, sagittal inlet, diagonal conjugate, biischial diameter, posterior sagittal diameter of midpelvis, sagittal midpelvic diameter, intertuberous distance, posterior sagittal diameter of outlet, angle of pubic arch, sagittal outlet, penal height, sacrum length and sacrum curvature. The relationship between all parameters and age was analyzed. (1) The posterior sagittal diameters of pelvic inlet of the 25 to 40 age group, 41 to 50 age group, >50 years age group were (53 ± 8), (51 ± 7), (48 ± 6) mm. The sagittal inlet of the three groups were (122 ± 8), (120 ± 9), (114 ± 8) mm. And the diagonal conjugate of the three groups were (135 ± 10), (132 ± 9), (127 ± 9) mm. All had significant differences among the three groups (P < 0.01) . (2) The posterior sagittal diameter of midpelvis of the three groups were (43 ± 6), (44 ± 6), (43 ± 7) mm, and the sagittal midpelvic diameter of the three groups were (119 ± 8), (120 ± 8), (119 ± 7) mm, with no significant difference among the three groups (P > 0.05). (3) The intertuberous distance of the three groups were (122 ± 11), (121 ± 10), (117 ± 11) mm, and the posterior sagittal diameter of outlet of the three groups were (56 ± 9), (58 ± 8), (57 ± 9) mm. There was no significant difference among the three groups (P > 0.05) .(4) Penal height of three groups were (31 ± 3), (33 ± 3), (34 ± 3) mm, there was with significant differences (P < 0.01) .(5) Pearson correlation analysis showed that penal height was positively correlated with age (r = 0.331, P < 0.05), while sagittal inlet, posterior sagittal diameter of inlet, diagonal conjugate, intertuberous distance, angle of pubic arch, sacrum length and sacrum curvature were negatively correlated with age (r = -0.120 to -0.343, P < 0.05). The shape of the pelvic inlet of Chinese southern Han female changed from sagittal elliptic into transverse elliptic form, and the posterior part of pelvic inlet became larger.Sacral concavity was increased and the pelvis became deeper. Mid pelvis and the pelvic outlet was almost unchanged, and showed no correlation with age.

  12. Physical Properties and Stability of Soft Gelled Chitosan-Based Nanoparticles.

    PubMed

    Goycoolea, Francisco M; Brunel, Fabrice; Gueddari, Nour E El; Coggiola, Anna; Lollo, Giovanna; Moerschbacher, Bruno M; Remuñán-López, Carmen; Delair, Thierry; Domard, Alain; Alonso, María J

    2016-12-01

    We addressed the role of the degree of acetylation (DA) and of M w of chitosan (CS) on the physical characteristics and stability of soft nanoparticles obtained through either ionic cross-linking with sodium tripolyphosphate (TPP), or reverse emulsion/gelation. Each of these methods affords nanoparticles (NPs) or nanogels (NGs), respectively. The size of CS-TPP NPs comprising CS of high M w (≈123-266 kDa) increases with DA (≈1.6%-56%), while it do not change for CS of low M w (≈11-13 kDa); the zeta potential (ζ) decreases with DA regardless of M w (ζ ≈+34.6 ± 2.6 to ≈+25.2 + 0.6 mV) and the NPs appear as spheres in transmission electron microscopy. Stability in various cell culture media (pH 7.4 at 37 °C) is greater for NPs made with CS of DA ≥ 27%. In turn, NGs exhibit larger sizes (520 ± 32 to 682 ± 27 nm) than do CS-TPP NPs, and can only be formed with CS of DA < 30%. The average diameter size for these NGs shows a monotonic increase with CS's M w . The physical properties and stability of these systems in biological media depend mostly on the DA of CS and its influence on the balance between hydrophilic/hydrophobic interactions. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Universal router concept

    NASA Technical Reports Server (NTRS)

    Pesch, W. A.

    1970-01-01

    Portable universal router can cut holes of large diameter and irregular shapes, machine recesses, and drill holes with certain edge-distance limitations. Rectangular and round holes may be cut without a template.

  14. The Three-Dimensional Distribution of αA-Crystalline in Rat Lenses and Its Possible Relation to Transparency

    PubMed Central

    Zampighi, Guido A.; Zampighi, Lorenzo; Lanzavecchia, Salvatore

    2011-01-01

    Lens transparency depends on the accumulation of massive quantities (600–800 mg/ml) of twelve primary crystallines and two truncated crystallines in highly elongated “fiber” cells. Despite numerous studies, major unanswered questions are how this heterogeneous group of proteins becomes organized to bestow the lens with its unique optical properties and how it changes during cataract formation. Using novel methods based on conical tomography and labeling with antibody/gold conjugates, we have profiled the 3D-distribution of the αA-crystalline in rat lenses at ∼2 nm resolutions and three-dimensions. Analysis of tomograms calculated from lenses labeled with anti-αA-crystalline and gold particles (∼3 nm and ∼7 nm diameter) revealed geometric patterns shaped as lines, isosceles triangles and polyhedrons. A Gaussian distribution centered at ∼7.5 nm fitted the distances between the ∼3 nm diameter gold conjugates. A Gaussian distribution centered at ∼14 nm fitted the Euclidian distances between the smaller and the larger gold particles and another Gaussian at 21–24 nm the distances between the larger particles. Independent of their diameters, tethers of 14–17 nm in length connected files of gold particles to thin filaments or clusters to ∼15 nm diameter “beads.” We used the information gathered from tomograms of labeled lenses to determine the distribution of the αA-crystalline in unlabeled lenses. We found that αA-crystalline monomers spaced ∼7 nm or αA-crystalline dimers spaced ∼15 nm center-to-center apart decorated thin filaments of the lens cytoskeleton. It thus seems likely that lost or gain of long-range order determines the 3D-structure of the fiber cell and possible also cataract formation. PMID:21909355

  15. Long-range electron transfer in a model for DNA

    NASA Astrophysics Data System (ADS)

    Endres, R. G.; Cox, D. L.

    2001-03-01

    Long-range electron transfer (ET) between well separated donor (D) and acceptor (A) sites through quantum mechanical tunneling is essential to many biological processes like respiration, photosynthesis and possibly DNA repair and damage. We are investigating the distance dependence of the electronic transition matrix element H_DA and hence of the electron transfer rate in a model for DNA. Fluorescence quenching in DNA at D-A distances of 40 Åand more suggests ET with an unusually high decay length β-1 of order 10 Å (S.O.Kelley and J.K.Barton, in:Metal Ions in Biological Systems), A.Sigel and H.Sigel, Eds., Marcel Dekker, New York, Vol.36, 1999. Assuming strong electron interactions on the D complex and suitable energetics, this could be explained by formation of a many electron Kondo boundstate. We obtain H_DA from the splitting between the two lowest adiabatic electronic eigenenergies, which constitute the potential energy surfaces (PES) of the nuclear motion in lowest order Born-Oppenheimer approximation. The PES are constructed by coupling D and A to local breathing modes and by making a semi-analytical variational ansatz for the adiabatic eigenstates. The results from the PES are compared with results from the Mulliken-Hush algorithm.

  16. WONCA 2015 preconference exchange: Self-discovery, friendship, and innovation amidst diversity and uncertainty

    PubMed Central

    Hoorick, Indra Van; Yakubu, Kenneth; Tsipou, Alexandra; Figueiredo, Ana Beatriz; Özkan, Nurşah; Atalay, Süheyla

    2016-01-01

    This commentary is the result of a long-distance creative writing project between young general practitioners (GPs) from around the world. They wrote this after participating in an exchange program in Turkey, where they had the opportunity to shadow a Turkish GP, and talk about primary health care around the world. This program was organized by the Vasco da Gama Movement (Vasco da Gama Movement is WONCA Europe's Working group for New and Future GPs: http://vdgm.woncaeurope.org/). PMID:27843816

  17. Experimental Evaluation of the Heat Sink Effect in Hepatic Microwave Ablation

    PubMed Central

    Ringe, Kristina I.; Lutat, Carolin; Rieder, Christian; Schenk, Andrea; Wacker, Frank; Raatschen, Hans-Juergen

    2015-01-01

    Purpose To demonstrate and quantify the heat sink effect in hepatic microwave ablation (MWA) in a standardized ex vivo model, and to analyze the influence of vessel distance and blood flow on lesion volume and shape. Materials and Methods 108 ex vivo MWA procedures were performed in freshly harvested pig livers. Antennas were inserted parallel to non-perfused and perfused (700,1400 ml/min) glass tubes (diameter 5mm) at different distances (10, 15, 20mm). Ablation zones (radius, area) were analyzed and compared (Kruskal-Wallis Test, Dunn’s multiple comparison Test). Temperature changes adjacent to the tubes were measured throughout the ablation cycle. Results Maximum temperature decreased significantly with increasing flow and distance (p<0.05). Compared to non-perfused tubes, ablation zones were significantly deformed by perfused tubes within 15mm distance to the antenna (p<0.05). At a flow rate of 700ml/min ablation zone radius was reduced to 37.2% and 80.1% at 10 and 15mm tube distance, respectively; ablation zone area was reduced to 50.5% and 89.7%, respectively. Conclusion Significant changes of ablation zones were demonstrated in a pig liver model. Considerable heat sink effect was observed within a diameter of 15mm around simulated vessels, dependent on flow rate. This has to be taken into account when ablating liver lesions close to vessels. PMID:26222431

  18. Influence of Low Molecular Weight Fractions of Humic Substances on Their Reducing Capacities and Distribution of Redox Functional Groups.

    NASA Astrophysics Data System (ADS)

    Yang, Z.; Jiang, J.

    2015-12-01

    Humic substances (HS) are redox-active organic compounds and their reducing capacities depend on molecule structure and distribution of redox functional groups (RFG). During dialysis experiments, initial HS were separated into low molecular weight fractions (LMWF, molecular weight <3,500 Da or <14,000 Da) and retentate. LMWF accounts for only 2% in TOC contents of HS molecules, while their reducing capacities are up to 33 times greater than those of initial HA. However, great amount of reducing capacities of LMWF does not cause decreasing reducing capacities of retentate relative to those of initial HA. Total reducing capacities of whole dialysis device were calculated for initial HA, retentate and LMWF in native and reduced state, and result suggests that releasing of LMWF leads to production and explosion of RFG. LWMF have great fluorescence intensities for protein-like fluorophores and humic acids-like fluorophores (quinone-like functional groups), where quinonoid π-π* transition is responsible for the great reducing capacities of LMWF. The 3,500 Da molecules (0.25 nm diameter) of HS are capable of stimulating transformation of redox-active metals or potential pollutants trapped in soil micropores (< 2 nm diameter). A development of relationship between reducing capacity and Ex / Em position provides a possibility to predicate relative reducing capacities of HS in treated raw water sample.

  19. Molecular Weight Cut-Off and Structural Analysis of Vacuum-Assisted Titania Membranes for Water Processing

    PubMed Central

    Abd Jalil, Siti Nurehan; Wang, David K.; Yacou, Christelle; Motuzas, Julius; Smart, Simon; Diniz da Costa, João C.

    2016-01-01

    This work investigates the structural formation and analyses of titania membranes (TM) prepared using different vacuum exposure times for molecular weight (MW) cut-off performance and oil/water separation. Titania membranes were synthesized via a sol-gel method and coated on macroporous alumina tubes followed by exposure to a vacuum between 30 and 1200 s and then calcined at 400 °C. X-ray diffraction and nitrogen adsorption analyses showed that the crystallite size and particle size of titania increased as a function of vacuum time. All the TM membranes were mesoporous with an average pore diameter of ~3.6 nm with an anatase crystal morphology. Water, glucose, sucrose, and polyvinylpyrrolidone with 40 and 360 kDa (PVP-40 kDa and PVP-360 kDa) were used as feed solutions for MW cut-off and hexadecane solution for oil filtration investigation. The TM membranes were not able to separate glucose and sucrose, thus indicating the membrane pore sizes are larger than the kinetic diameter of sucrose of 0.9 nm, irrespective of vacuum exposure time. They also showed only moderate rejection (20%) of the smaller PVP-40 kDa, however, all the membranes were able to obtain an excellent rejection of near 100% for the larger PVP-360 kDa molecule. Furthermore, the TM membranes were tested for the separation of oil emulsions with a high concentration of oil (3000 ppm), reaching high oil rejections of more than 90% of oil. In general, the water fluxes increased with the vacuum exposure time indicating a pore structural tailoring effect. It is therefore proposed that a mechanism of pore size tailoring was formed by an interconnected network of Ti–O–Ti nanoparticles with inter-particle voids, which increased as TiO2 nanoparticle size increased as a function of vacuum exposure time, and thus reduced the water transport resistance through the TM membranes. PMID:28774057

  20. Probing the size of proteins with glass nanopores

    NASA Astrophysics Data System (ADS)

    Steinbock, L. J.; Krishnan, S.; Bulushev, R. D.; Borgeaud, S.; Blokesch, M.; Feletti, L.; Radenovic, A.

    2014-11-01

    Single molecule studies using nanopores have gained attention due to the ability to sense single molecules in aqueous solution without the need to label them. In this study, short DNA molecules and proteins were detected with glass nanopores, whose sensitivity was enhanced by electron reshaping which decreased the nanopore diameter and created geometries with a reduced sensing length. Further, proteins having molecular weights (MW) ranging from 12 kDa to 480 kDa were detected, which showed that their corresponding current peak amplitude changes according to their MW. In the case of the 12 kDa ComEA protein, its DNA-binding properties to an 800 bp long DNA molecule was investigated. Moreover, the influence of the pH on the charge of the protein was demonstrated by showing a change in the translocation direction. This work emphasizes the wide spectrum of detectable molecules using nanopores from glass nanocapillaries, which stand out because of their inexpensive, lithography-free, and rapid manufacturing process.Single molecule studies using nanopores have gained attention due to the ability to sense single molecules in aqueous solution without the need to label them. In this study, short DNA molecules and proteins were detected with glass nanopores, whose sensitivity was enhanced by electron reshaping which decreased the nanopore diameter and created geometries with a reduced sensing length. Further, proteins having molecular weights (MW) ranging from 12 kDa to 480 kDa were detected, which showed that their corresponding current peak amplitude changes according to their MW. In the case of the 12 kDa ComEA protein, its DNA-binding properties to an 800 bp long DNA molecule was investigated. Moreover, the influence of the pH on the charge of the protein was demonstrated by showing a change in the translocation direction. This work emphasizes the wide spectrum of detectable molecules using nanopores from glass nanocapillaries, which stand out because of their inexpensive, lithography-free, and rapid manufacturing process. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr05001k

  1. Design of a multifiber light delivery system for photoacoustic-guided surgery.

    PubMed

    Eddins, Blackberrie; Bell, Muyinatu A Lediju

    2017-04-01

    This work explores light delivery optimization for photoacoustic-guided minimally invasive surgeries, such as the endonasal transsphenoidal approach. Monte Carlo simulations were employed to study three-dimensional light propagation in tissue, comprising one or two 4-mm diameter arteries located 3 mm below bone, an absorbing metallic drill contacting the bone surface, and a single light source placed next to the 2.4-mm diameter drill shaft with a 2.9-mm diameter spherical drill tip. The optimal fiber distance from the drill shaft was determined from the maximum normalized fluence to the underlying artery. Using this optimal fiber-to-drill shaft distance, Zemax simulations were employed to propagate Gaussian beams through one or more 600 micron-core diameter optical fibers for detection on the bone surface. When the number of equally spaced fibers surrounding the drill increased, a single merged optical profile formed with seven or more fibers, determined by thresholding the resulting light profile images at 1 / e times the maximum intensity. We used these simulations to inform design requirements, build a one to seven multifiber light delivery prototype to surround a surgical drill, and demonstrate its ability to simultaneously visualize the tool tip and blood vessel targets in the absence and presence of bone. The results and methodology are generalizable to multiple interventional photoacoustic applications.

  2. Design of a multifiber light delivery system for photoacoustic-guided surgery

    NASA Astrophysics Data System (ADS)

    Eddins, Blackberrie; Bell, Muyinatu A. Lediju

    2017-04-01

    This work explores light delivery optimization for photoacoustic-guided minimally invasive surgeries, such as the endonasal transsphenoidal approach. Monte Carlo simulations were employed to study three-dimensional light propagation in tissue, comprising one or two 4-mm diameter arteries located 3 mm below bone, an absorbing metallic drill contacting the bone surface, and a single light source placed next to the 2.4-mm diameter drill shaft with a 2.9-mm diameter spherical drill tip. The optimal fiber distance from the drill shaft was determined from the maximum normalized fluence to the underlying artery. Using this optimal fiber-to-drill shaft distance, Zemax simulations were employed to propagate Gaussian beams through one or more 600 micron-core diameter optical fibers for detection on the bone surface. When the number of equally spaced fibers surrounding the drill increased, a single merged optical profile formed with seven or more fibers, determined by thresholding the resulting light profile images at 1/e times the maximum intensity. We used these simulations to inform design requirements, build a one to seven multifiber light delivery prototype to surround a surgical drill, and demonstrate its ability to simultaneously visualize the tool tip and blood vessel targets in the absence and presence of bone. The results and methodology are generalizable to multiple interventional photoacoustic applications.

  3. Experimental investigation of an axisymmetric free jet with an initially uniform velocity profile

    NASA Technical Reports Server (NTRS)

    Labus, T. L.; Symons, E. P.

    1972-01-01

    An experimental investigation was conducted to determine the flow characteristics of a circular free helium jet having an initially uniform velocity profile. Complete velocity profiles are presented at Reynolds numbers of 1027 and 4571 at 0, 3, 6, 10, 15, and 20 nozzle diameters (where possible) from the nozzle exit. Centerline velocity decay and potential core length were obtained over a range of Reynolds numbers from 155 to 5349 at distances up to and including 25 nozzle diameters from the nozzle exit. The angles of spread associated with the diffusion of the jet downstream of the nozzle are also given. Axial jet momentum flux and entrained mass flux, at various distances downstream of the nozzle, are presented as a function of the jet Reynolds number.

  4. 70 DA White Dwarfs Identified in LAMOST Pilot Survey

    NASA Astrophysics Data System (ADS)

    Zhao, J. K.; Luo, A. L.; Oswalt, T. D.; Zhao, G.

    2013-06-01

    We present a spectroscopically identified catalog of 70 DA white dwarfs (WDs) from the LAMOST pilot survey. Thirty-five are found to be new identifications after cross-correlation with the Eisenstein et al. and Villanova catalogs. The effective temperature and gravity of these WDs are estimated by Balmer lines fitting. Most of them are hot WDs. The cooling times and masses of these WDs are estimated by interpolation in theoretical evolution tracks. The peak of the mass distribution is found to be ~0.6 M ⊙, which is consistent with prior work in the literature. The distances of these WDs are estimated using the method of synthetic spectral distances. All of these WDs are found to be in the Galactic disk from our analysis of space motions. Our sample supports the expectation that WDs with high mass are concentrated near the plane of the Galactic disk.

  5. 70 DA WHITE DWARFS IDENTIFIED IN LAMOST PILOT SURVEY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zhao, J. K.; Luo, A. L.; Zhao, G.

    2013-06-01

    We present a spectroscopically identified catalog of 70 DA white dwarfs (WDs) from the LAMOST pilot survey. Thirty-five are found to be new identifications after cross-correlation with the Eisenstein et al. and Villanova catalogs. The effective temperature and gravity of these WDs are estimated by Balmer lines fitting. Most of them are hot WDs. The cooling times and masses of these WDs are estimated by interpolation in theoretical evolution tracks. The peak of the mass distribution is found to be {approx}0.6 M {sub Sun }, which is consistent with prior work in the literature. The distances of these WDs aremore » estimated using the method of synthetic spectral distances. All of these WDs are found to be in the Galactic disk from our analysis of space motions. Our sample supports the expectation that WDs with high mass are concentrated near the plane of the Galactic disk.« less

  6. [Distance learning using internet in the field of bioengineering].

    PubMed

    Ciobanu, O

    2003-01-01

    The Leonardo da Vinci training programme supports innovative transnational initiatives for promoting the knowledge, aptitudes and skills necessary for successful integration into working life. Biomedical engineering is an emerging interdisciplinary field that contributes to understand, define and solve problems in biomedical technology within industrial and health service contexts. Paper presents a Leonardo da Vinci pilot-project called Web-based learning and training in the field of biomedical and design engineering (WEBD). This project has started on 2001. The WEBD project proposes to use advanced learning technologies to provide education in the www. Project uses interactive 3D graphics and virtual reality tools. The WEBD distance training permits users to experience and interact with a life-like model or environment, in safety and at convenient times, while providing a degree of control over the simulation that is usually not possible in the real-life situation.

  7. Evaluation of Verisyse and Artiflex phakic intraocular lenses during accommodation using Visante optical coherence tomography.

    PubMed

    Güell, José Luis; Morral, Merce; Gris, Oscar; Gaytan, Javier; Sisquella, Maite; Manero, Felicidad

    2007-08-01

    To perform a dynamic study of the relationship between Verisyse (AMO) and Artiflex (Ophtec B.V.) phakic intraocular lenses (pIOLs) and anterior chamber structures during accommodation using optical coherence tomography (OCT) (Visante, Carl Zeiss Meditec, Inc.) Institutional practice. Eleven myopic patients were randomly selected to have implantation of a Verisyse pIOL in 1 eye and an Artiflex pIOL in the other. Using a 2-dimensional image, dynamic measurements of the relationship between the anterior surface of the pIOL and the corneal endothelium, the posterior surface of the pIOL and the anterior surface of the crystalline lens, and the pupil diameter were performed using Visante OCT. Physiological accommodation was stimulated by adding lenses in 1.00 diopter (D) steps from +1.00 to -7.00 D. Both groups had a significant decrease in pupil diameter (P<.0001, generalized linear model [GLM]) and in the distance between the anterior surface of the pIOL and the corneal endothelium (P<.0001, GLM) with accommodation. There were no statistically significant changes in the distance between the posterior surface of either pIOL and the anterior surface of the crystalline lens (P = .2845, GLM). There were no statistically significant differences between the 2 pIOLs in any measurement (P>.05, GLM). The results fit with Helmholtz' theory of accommodation as forward movement of the diaphragm iris-crystalline lens was seen. There was a decrease in the distance between the pIOL and corneal endothelium and in the pupil diameter, whereas the distance between both pIOLs and the crystalline lens remained constant throughout the accommodation examination. This suggests that the risk for cataract from intermittent contact between the crystalline lens and IOL from accommodative effort is unlikely.

  8. Effect of Processing Parameters on the Morphology of PVDF Electrospun Nanofiber

    NASA Astrophysics Data System (ADS)

    Zulfikar, M. A.; Afrianingsih, I.; Nasir, M.; Alni, A.

    2018-03-01

    Electrospinning is a process that produces continuous polymer fibers with diameters in the submicron range through the action of an external electric field imposed on a polymer solution or melt. Because of the tiny diameter in several hundreds of nanometers and the high porosity, electrospun membranes show potential applications in extensive areas such as filtration systems, biomedical tissue templates, drug delivery membranes, and so on. In the electrospinning process, some parameters such as polymer concentration, feeding rate of the polymer solution, additives, humidity, viscosity, surface tension, applied voltage, and nozzle-to ground collector distance will affect the fiber diameter and morphology. In this work, we have evaluated the effects of two processing parameters including the flow rate of the polymer solution and nozzle-to ground collector distance, on the morphology of the fibers formed. The solutions used in the electrospinning experiments were prepared using Poly(vinylidene fluoride) (PVDF). This material was dissolved in N,N-dimethylformamide (DMF) to make solutions with concentrations of 20 wt%. These solutions was electrospun using a 5 mL plastic syringe with an 8 gauge stainless needle at an applied voltage of 20.0 kV, a flow rate of 0.02-0.04 mL/min and nozzle-to ground collector distance of 12 and 15 cm. Electrospinning of PVDF polymer solution was performed in horizontal alignment having a grounded aluminum foil which serves as a collector. The nanofibers obtained were characterized by polarizing optical microscope. We find that the low flow rate of the polymer solution and nozzle-to ground collector distance are strongly correlated with the formation of bead defects in the fibers.

  9. Assessing the Potential of Low-Cost 3D Cameras for the Rapid Measurement of Plant Woody Structure

    PubMed Central

    Nock, Charles A; Taugourdeau, Olivier; Delagrange, Sylvain; Messier, Christian

    2013-01-01

    Detailed 3D plant architectural data have numerous applications in plant science, but many existing approaches for 3D data collection are time-consuming and/or require costly equipment. Recently, there has been rapid growth in the availability of low-cost, 3D cameras and related open source software applications. 3D cameras may provide measurements of key components of plant architecture such as stem diameters and lengths, however, few tests of 3D cameras for the measurement of plant architecture have been conducted. Here, we measured Salix branch segments ranging from 2–13 mm in diameter with an Asus Xtion camera to quantify the limits and accuracy of branch diameter measurement with a 3D camera. By scanning at a variety of distances we also quantified the effect of scanning distance. In addition, we also test the sensitivity of the program KinFu for continuous 3D object scanning and modeling as well as other similar software to accurately record stem diameters and capture plant form (<3 m in height). Given its ability to accurately capture the diameter of branches >6 mm, Asus Xtion may provide a novel method for the collection of 3D data on the branching architecture of woody plants. Improvements in camera measurement accuracy and available software are likely to further improve the utility of 3D cameras for plant sciences in the future. PMID:24287538

  10. Submerged jet mixing in nuclear waste tanks: a correlation for jet velocity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Daas, M.; Srivastava, R.; Roelant, D.

    2007-07-01

    Experimental studies were carried out in jet-stirred slurry tanks to correlate the influence of nozzle diameter, initial jet flow velocity, submerged depth of jet, tank diameter and slurry properties on the jet axial velocity. The tanks used in the experimental work had diameters of 0.3 m (1-ft) and 2.13 m (7-ft). The fluids emerged from nozzles of 0.003 m and 0.01 m in diameter, 1/8-inch and 3/8-inch respectively. The examined slurries were non-Newtonian and contained 5 weight percent total insoluble solids. The axial velocities along the centerline of a submerged jet stream were measured at different jet flow rates andmore » at various distances from the nozzle orifice (16 to 200 nozzle diameters) utilizing electromagnetic velocity meter. A new simplified correlation was developed to describe the jet axial velocity in submerged jet stirred tanks utilizing more than 350 data points. The Buckingham Pi theorem and non-linear regression method of multivariate approximation, in conjunction with the Gauss-Jordan elimination method, were used to develop the new correlation. The new correlation agreed well with the experimental data obtained from the current study. Good agreement was also possible with literature data except at large distances from the nozzle as the model slightly overestimated the jet axial velocity. The proposed correlation incorporates the contributions of system geometry, fluid properties, and external forces. Furthermore, it provides reasonable estimates of jet axial velocity. (authors)« less

  11. Controlling Laser Spot Size in Outer Space

    NASA Technical Reports Server (NTRS)

    Bennett, Harold E.

    2005-01-01

    Three documents discuss a method of controlling the diameter of a laser beam projected from Earth to any altitude ranging from low orbit around the Earth to geosynchronous orbit. Such laser beams are under consideration as means of supplying power to orbiting spacecraft at levels of the order of tens of kilowatts apiece. Each such beam would be projected by use of a special purpose telescope having an aperture diameter of 15 m or more. Expanding the laser beam to such a large diameter at low altitude would prevent air breakdown and render the laser beam eyesafe. Typically, the telescope would include an adaptive-optics concave primary mirror and a convex secondary mirror. The laser beam transmitted out to the satellite would remain in the near field on the telescope side of the beam waist, so that the telescope focal point would remain effective in controlling the beam width. By use of positioning stages having submicron resolution and repeatability, the relative positions of the primary and secondary mirrors would be adjusted to change the nominal telescope object and image distances to obtain the desired beam diameter (typically about 6 m) at the altitude of the satellite. The limiting distance D(sub L) at which a constant beam diameter can be maintained is determined by the focal range of the telescope 4 lambda f(sup 2) where lambda is the wavelength and f the f/number of the primary mirror. The shorter the wavelength and the faster the mirror, the longer D(sub L) becomes.

  12. Bias of cylinder diameter estimation from ground-based laser scanners with different beam widths: A simulation study

    NASA Astrophysics Data System (ADS)

    Forsman, Mona; Börlin, Niclas; Olofsson, Kenneth; Reese, Heather; Holmgren, Johan

    2018-01-01

    In this study we have investigated why diameters of tree stems, which are approximately cylindrical, are often overestimated by mobile laser scanning. This paper analyzes the physical processes when using ground-based laser scanning that may contribute to a bias when estimating cylinder diameters using circle-fit methods. A laser scanner simulator was implemented and used to evaluate various properties, such as distance, cylinder diameter, and beam width of a laser scanner-cylinder system to find critical conditions. The simulation results suggest that a positive bias of the diameter estimation is expected. Furthermore, the bias follows a quadratic function of one parameter - the relative footprint, i.e., the fraction of the cylinder width illuminated by the laser beam. The quadratic signature opens up a possibility to construct a compensation model for the bias.

  13. A spectro-interferometric view of l Carinae's modulated pulsations

    NASA Astrophysics Data System (ADS)

    Anderson, Richard I.; Mérand, Antoine; Kervella, Pierre; Breitfelder, Joanne; Eyer, Laurent; Gallenne, Alexandre

    Classical Cepheids are radially pulsating stars that enable important tests of stellar evolution and play a crucial role in the calibration of the local Hubble constant. l Carinae is a particularly well-known distance calibrator, being the closest long-period (P ~ 35.5 d) Cepheid and subtending the largest angular diameter. We have carried out an unprecedented observing program to investigate whether recently discovered cycle-to-cycle changes (modulations) of l Carinae's radial velocity (RV) variability are mirrored by its variability in angular size. To this end, we have secured a fully contemporaneous dataset of high-precision RVs and high-precision angular diameters. Here we provide a concise summary of our project and report preliminary results. We confirm the modulated nature of the RV variability and find tentative evidence of cycle-to-cycle differences in l Car's maximal angular diameter. Our analysis is exploring the limits of state-of-the-art instrumentation and reveals additional complexity in the pulsations of Cepheids. If confirmed, our result suggests a previously unknown pulsation cycle dependence of projection factors required for determining Cepheid distances via the Baade-Wesselink technique.

  14. A correlation method to predict the surface pressure distribution of an infinite plate or a body of revolution from which a jet is issuing

    NASA Technical Reports Server (NTRS)

    Perkins, S. C., Jr.; Mendenhall, M. R.

    1980-01-01

    A correlation method to predict pressures induced on an infinite plate by a jet exhausting normal to the plate into a subsonic free stream was extended to jets exhausting at angles to the plate and to jets exhausting normal to the surface of a body revolution. The complete method consisted of an analytical method which models the blockage and entrainment properties of the jet and an empirical correlation which accounts for viscous effects. For the flat plate case, the method was applicable to jet velocity ratios up to ten, jet inclination angles up to 45 deg from the normal, and radial distances up to five diameters from the jet. For the body of revolution case, the method was applicable to a body at zero degrees angle of attack, jet velocity ratios 1.96 and 3.43, circumferential angles around the body up to 25 deg from the jet, axial distances up to seven diameters from the jet, and jet-to-body diameter ratios less than 0.1.

  15. Genotype and elevation influence Spartina alterniflora colonization and growth in a created salt marsh

    USGS Publications Warehouse

    Proffitt, C.E.; Travis, S.E.; Edwards, K.R.

    2003-01-01

    Colonization, growth, and clonal morphology differ with genotype and are influenced by elevation. Local adaptation of Spartina alterniflora to environmental conditions may lead to dominance by different suites of genotypes in different locations within a marsh. In a constructed marsh, we found reduced colonization in terms of density of clones with increasing distance from edge in a 200-ha mudflat created in 1996; however, growth in diameter was not different among three 100-m-long zones that differed in distance from site edge. Distance from edge was confounded by elevation in this comparison of natural colonization. The rate of clonal expansion in diameter was 3.1 m/yr, and clonal growth was linear over the 28 mo of the study. The area dominated by S. alterniflora in the three distance zones increased concomitantly with clonal growth. However, the lower initial clonal densities and colonization by other plant species resulted in reduced overall dominance by S. alterniflora in the two more-interior locations. Seedling recruitment was an important component of S. alterniflora colonization at all elevations and distances from edge two years after site creation. Seedlings were spatially very patchy and tended to occur near clones that probably produced them. A field experiment revealed that S. alterniflora height and total stem length varied with genotype, while stem density and flowering stem density did not. Differences between edge and center of clonal patches also occurred for some response variables, and there were also significant interactions with genotype. Differences between edge and center are interpreted as differences in clone morphology. Elevation differences over distances of a few meters influenced total stem length and flowering stem density but not other response variables. Clones that were larger in diameter also tended to have greater stem heights and total stem lengths. A number of plant morphological measures were found to vary significantly among the five genotypes and had broad-sense heritabilities ranging up to 0.71. These results indicate that S. alterniflora populations developing on new substrata colonize broadly, but growth and reproduction vary with genotype and are influenced by changes in elevation (range: 11.8 cm), and probably other environmental factors, over relatively small distances. Differences in growth and clone morphology of different genets, and the frequent occurrence of seedlings throughout the site, underscore the importance of genetic variability in natural and created populations.

  16. Controller evaluations of the descent advisor automation aid

    NASA Technical Reports Server (NTRS)

    Tobias, Leonard; Volckers, Uwe; Erzberger, Heinz

    1989-01-01

    An automation aid to assist air traffic controllers in efficiently spacing traffic and meeting arrival times at a fix has been developed at NASA Ames Research Center. The automation aid, referred to as the descent advisor (DA), is based on accurate models of aircraft performance and weather conditions. The DA generates suggested clearances, including both top-of-descent point and speed profile data, for one or more aircraft in order to achieve specific time or distance separation objectives. The DA algorithm is interfaced with a mouse-based, menu-driven controller display that allows the air traffic controller to interactively use its accurate predictive capability to resolve conflicts and issue advisories to arrival aircraft. This paper focuses on operational issues concerning the utilization of the DA, specifically, how the DA can be used for prediction, intrail spacing, and metering. In order to evaluate the DA, a real time simulation was conducted using both current and retired controller subjects. Controllers operated in teams of two, as they do in the present environment; issues of training and team interaction will be discussed. Evaluations by controllers indicated considerable enthusiasm for the DA aid, and provided specific recommendations for using the tool effectively.

  17. Single microparticle launching method using two-stage light-gas gun for simulating hypervelocity impacts of micrometeoroids and space debris.

    PubMed

    Kawai, Nobuaki; Tsurui, Kenji; Hasegawa, Sunao; Sato, Eiichi

    2010-11-01

    A single microparticle launching method is described to simulate the hypervelocity impacts of micrometeoroids and microdebris on space structures at the Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency. A microparticle placed in a sabot with slits is accelerated using a rifled two-stage light-gas gun. The centrifugal force provided by the rifling in the launch tube separates the sabot. The sabot-separation distance and the impact-point deviation are strongly affected by the combination of the sabot diameter and the bore diameter, and by the projectile diameter. Using this method, spherical projectiles of 1.0-0.1 mm diameter were launched at up to 7 km/s.

  18. Single microparticle launching method using two-stage light-gas gun for simulating hypervelocity impacts of micrometeoroids and space debris

    NASA Astrophysics Data System (ADS)

    Kawai, Nobuaki; Tsurui, Kenji; Hasegawa, Sunao; Sato, Eiichi

    2010-11-01

    A single microparticle launching method is described to simulate the hypervelocity impacts of micrometeoroids and microdebris on space structures at the Institute of Space and Astronautical Science, Japan Aerospace Exploration Agency. A microparticle placed in a sabot with slits is accelerated using a rifled two-stage light-gas gun. The centrifugal force provided by the rifling in the launch tube separates the sabot. The sabot-separation distance and the impact-point deviation are strongly affected by the combination of the sabot diameter and the bore diameter, and by the projectile diameter. Using this method, spherical projectiles of 1.0-0.1 mm diameter were launched at up to 7 km/s.

  19. Reducing body myopathy and desmin storage in skeletal muscle: morphological and biochemical findings.

    PubMed

    Bertini, E; Salviati, G; Apollo, F; Ricci, E; Servidei, S; Broccolini, A; Papacci, M; Tonali, P

    1994-01-01

    We describe clinical, morphological and biochemical findings of a patient with reducing body myopathy (RBM). This 15-year-old patient was affected by severe limb-girdle progressive myopathy with asymmetric distribution. Muscle biopsy showed many fibers with cytoplasmic polymorphic masses, which stained dark purple with modified Gomori's trichrome, associated with proliferation of cytoplasmic bodies. Cytoplasmic polymorphic masses showed marked reducing activity with menadione-nitro blue tetrazolium reaction. Ultrastructurally, there was great amount of highly electron-dense tubular-filamentous structures of 16-17 nm in diameter. Immunohistochemistry showed that many fibers were positive for desmin. Sodium dodecyl sulfate-electrophoresis disclosed an increase in two bands of approximately 53 and 70 kDa, and Western blot demonstrated that the 53-kDa band was desmin. It was not possible to characterize the 70-kDa protein further.

  20. Leonardo's Rule, Self-Similarity, and Wind-Induced Stresses in Trees

    NASA Astrophysics Data System (ADS)

    Eloy, Christophe

    2011-12-01

    Examining botanical trees, Leonardo da Vinci noted that the total cross section of branches is conserved across branching nodes. In this Letter, it is proposed that this rule is a consequence of the tree skeleton having a self-similar structure and the branch diameters being adjusted to resist wind-induced loads.

  1. The proportion of the face in younger adults using the thumb rule of Leonardo da Vinci.

    PubMed

    Oguz, O

    1996-01-01

    The present study was conducted to examine whether the thumb rule of Leonardo da Vinci could be an objective method in the determination of the natural and artistic proportions of human face. In this study, a sample of 400 subjects (200 male and 200 female, 22-25 years old) was used. Measurements were made of the length of thumb, the length of ear, the approximate distances between the hair line and the glabella or eyebrows, between the glabella or eyebrows and the tip of the nose and the distance between the nose and the chin, and the distance between the ear and the lateral aspect of the eye. The results obtained in the males and females showed significant (p < 0.01) correlations between the length of thumb and the proportions of the face examined in the study. Additionally, the height of the face was found to be almost three times the length of the thumb. However, the measurements obtained from female subjects were on average smaller than those taken from males. The results obtained in this experiment could be of value in understanding of the evaluation of the face for the people working in plastic surgery or art.

  2. Soot superaggregates from flaming wildfires and their direct radiative forcing.

    PubMed

    Chakrabarty, Rajan K; Beres, Nicholas D; Moosmüller, Hans; China, Swarup; Mazzoleni, Claudio; Dubey, Manvendra K; Liu, Li; Mishchenko, Michael I

    2014-07-01

    Wildfires contribute significantly to global soot emissions, yet their aerosol formation mechanisms and resulting particle properties are poorly understood and parameterized in climate models. The conventional view holds that soot is formed via the cluster-dilute aggregation mechanism in wildfires and emitted as aggregates with fractal dimension Df ≈ 1.8 mobility diameter Dm ≤ 1 μm, and aerodynamic diameter Da ≤ 300 nm. Here we report the ubiquitous presence of soot superaggregates (SAs) in the outflow from a major wildfire in India. SAs are porous, low-density aggregates of cluster-dilute aggregates with characteristic Df ≈ 2.6, Dm > 1 μm, and Da ≤ 300 nm that form via the cluster-dense aggregation mechanism. We present additional observations of soot SAs in wildfire smoke-laden air masses over Northern California, New Mexico, and Mexico City. At 550 nm wavelength, [corrected] we estimate that SAs contribute, per unit optical depth, up to 35% less atmospheric warming than freshly-emitted (D(f) ≈ 1.8) [corrected] aggregates, and ≈90% more warming than the volume-equivalent spherical soot particles simulated in climate models.

  3. Soot superaggregates from flaming wildfires and their direct radiative forcing

    PubMed Central

    Chakrabarty, Rajan K.; Beres, Nicholas D.; Moosmüller, Hans; China, Swarup; Mazzoleni, Claudio; Dubey, Manvendra K.; Liu, Li; Mishchenko, Michael I.

    2014-01-01

    Wildfires contribute significantly to global soot emissions, yet their aerosol formation mechanisms and resulting particle properties are poorly understood and parameterized in climate models. The conventional view holds that soot is formed via the cluster-dilute aggregation mechanism in wildfires and emitted as aggregates with fractal dimension Df ≈ 1.8 mobility diameter Dm ≤ 1 μm, and aerodynamic diameter Da ≤ 300 nm. Here we report the ubiquitous presence of soot superaggregates (SAs) in the outflow from a major wildfire in India. SAs are porous, low-density aggregates of cluster-dilute aggregates with characteristic Df ≈ 2.6, Dm > 1 μm, and Da ≤ 300 nm that form via the cluster-dense aggregation mechanism. We present additional observations of soot SAs in wildfire smoke-laden air masses over Northern California, New Mexico, and Mexico City. We estimate that SAs contribute, per unit optical depth, up to 35% less atmospheric warming than freshly-emitted (Df ≈ 1.8) aggregates, and ≈90% more warming than the volume-equivalent spherical soot particles simulated in climate models. PMID:24981204

  4. An assessment of the utility of a non-metric digital camera for measuring standing trees

    Treesearch

    Neil Clark; Randolph H. Wynne; Daniel L. Schmoldt; Matthew F. Winn

    2000-01-01

    Images acquired with a commercially available digital camera were used to make measurements on 20 red oak (Quercus spp.) stems. The ranges of diameter at breast height (DBH) and height to a 10 cm upper-stem diameter were 16-66 cm and 12-20 m, respectively. Camera stations located 3, 6, 9, 12, and 15 m from the stem were studied to determine the best distance to be...

  5. CHRIS: Hazard Assessment Handbook

    DTIC Science & Technology

    1977-12-12

    3.10 Vectorial Addition of Sea and Wind Currents 50 B1 Flame Length for Gases Venting Through Holes 177 B2 Equivalent...determined are: • Flame length (flame height), • Safe distance for people (away from the flame) • Safe distance for people in fire-protective clothing (away...pencil so it can be erased) Determine the flame length from Figure B1, using the venting hole diameter and the curve corresponding to the specific

  6. Close-in characteristics of LH2/LOX reactions

    NASA Technical Reports Server (NTRS)

    Riehl, W. A.; Ullian, L. J.

    1985-01-01

    In deriving shock overpressures from space vehicles employing LH2 and LOX, separate methods of analyses and prediction are recommended, as a function of the distance. Three methods of treatment are recommended. For the Far Field - where the expected shock overpressure is less than 40 psi (lambda = 5) - use the classical PYRO approach to determine TNT yield, and employ classical ordnance (Kingery) curve to obtain the overall value. For the Close-In Range, a suggested limit is 3D, or a zone from a distance of three times the tank diameter to the tank wall. Rather than estimate a specific distance from the center of explosion to the target, it is only necessary to estimate whether this could be within one, two, or three diameters away from the wall; i.e., in the 1, 2, or 3D zone. Then assess whether mixing mode is by the PYRO CBGS (spill) mode or CBM (internal mixing) mode. From the zone and mixing mode, the probability of attaining various shock overpressures is determined from the plots provided herein. For the transition zone, between 40 psi and the 3D distance, it is tentatively recommended that both of the preceding methods be used, and to be conservative, the higher resulting value be used.

  7. Experimental and Analytical Determination of the Geometric Far Field for Round Jets

    NASA Technical Reports Server (NTRS)

    Koch, L. Danielle; Bridges, James E.; Brown, Clifford E.; Khavaran, Abbas

    2005-01-01

    An investigation was conducted at the NASA Glenn Research Center using a set of three round jets operating under unheated subsonic conditions to address the question: "How close is too close?" Although sound sources are distributed at various distances throughout a jet plume downstream of the nozzle exit, at great distances from the nozzle the sound will appear to emanate from a point and the inverse-square law can be properly applied. Examination of normalized sound spectra at different distances from a jet, from experiments and from computational tools, established the required minimum distance for valid far-field measurements of the sound from subsonic round jets. Experimental data were acquired in the Aeroacoustic Propulsion Laboratory at the NASA Glenn Research Center. The WIND computer program solved the Reynolds-Averaged Navier-Stokes equations for aerodynamic computations; the MGBK jet-noise prediction computer code was used to predict the sound pressure levels. Results from both the experiments and the analytical exercises indicated that while the shortest measurement arc (with radius approximately 8 nozzle diameters) was already in the geometric far field for high-frequency sound (Strouhal number >5), low-frequency sound (Strouhal number <0.2) reached the geometric far field at a measurement radius of at least 50 nozzle diameters because of its extended source distribution.

  8. Stress concentration in the vicinity of a hole defect under conditions of Hertzian contact

    NASA Technical Reports Server (NTRS)

    Yamamoto, T.; Eguchi, M.; Murayama, K.

    1981-01-01

    Two-dimensional photoelastic stress analyses were conducted for epoxy resin models containing a hole defect under the conditions of Hertzian contact. Stress concentrations around the defect were determined as a function of several parameters. These were hole diameter, its vertical distance from the contact surface, and the horizontal distance from the Hertzian contact area. Also determined was the effect of tangential traction (generated by a friction coefficient of 0.1) on the stress concentration. Sharp stress concentrations occur in the vicinity of both the left and the right side of the hole. The stress concentration becomes more distinct the larger the hole diameter and the smaller the distance between the hole and the contact surface. The stress concentration is greatest when the disk imposing a normal load is located at the contact surface directly over the hole. The magnitude and the location of stress concentration varies with the distance between the Hertzian contact area and the hole. Taking into account the stress amplitude, the area which can be involved in a process of rolling contact fatigue seems to be confined to a shallow region at both sides of the hole. The effect of tangential traction is comparatively small on the stress concentration around the hole.

  9. Serendipitous discovery of a faint dwarf galaxy near a Local Volume dwarf

    NASA Astrophysics Data System (ADS)

    Makarova, L. N.; Makarov, D. I.; Antipova, A. V.; Karachentsev, I. D.; Tully, R. B.

    2018-03-01

    A faint dwarf irregular galaxy has been discovered in the HST/ACS field of LV J1157+5638. The galaxy is resolved into individual stars, including the brightest magnitude of the red giant branch. The dwarf is very likely a physical satellite of LV J1157+5638. The distance modulus of LV J1157+5638 using the tip of the red giant branch (TRGB) distance indicator is 29.82 ± 0.09 mag (D = 9.22 ± 0.38 Mpc). The TRGB distance modulus of LV J1157+5638 sat is 29.76 ± 0.11 mag (D = 8.95 ± 0.42 Mpc). The distances to the two galaxies are consistent within the uncertainties. The projected separation between them is only 3.9 kpc. LV J1157+5638 has a total absolute V magnitude of -13.26 ± 0.10 and linear Holmberg diameter of 1.36 kpc, whereas its faint satellite LV J1157+5638 sat has MV = -9.38 ± 0.13 mag and Holmberg diameter of 0.37 kpc. Such a faint dwarf was discovered for the first time beyond the nearest 4 Mpc from us. The presence of main-sequence stars in both galaxies unambiguously indicates the classification of the objects as dwarf irregulars with recent or ongoing star formation events in both galaxies.

  10. Characterization of the High-Albedo NEA 3691 Bede

    NASA Technical Reports Server (NTRS)

    Wooden, Diane H.; Lederer, Susan M.; Jehin, Emmanuel; Rozitis, Benjamin; Jefferson, Jeffrey D.; Nelson, Tyler W.; Dotson, Jessie L.; Ryan, Erin L.; Howell, Ellen S.; Fernandez, Yanga R.; hide

    2016-01-01

    Characterization of NEAs provides important inputs to models for atmospheric entry, risk assessment and mitigation. Diameter is a key parameter because diameter translates to kinetic energy in atmospheric entry. Diameters can be derived from the absolute magnitude, H(PA=0deg), and from thermal modeling of observed IR fluxes. For both methods, the albedo (pv) is important - high pv surfaces have cooler temperatures, larger diameters for a given Hmag, and shallower phase curves (larger slope parameter G). Thermal model parameters are coupled, however, so that a higher thermal inertia also results in a cooler surface temperature. Multiple parameters contribute to constraining the diameter. Observations made at multiple observing geometries can contribute to understanding the relationships between and potentially breaking some of the degeneracies between parameters. We present data and analyses on NEA 3691 Bede with the aim of best constraining the diameter and pv from a combination of thermal modeling and light curve analyses. We employ our UKIRT+Michelle mid-IR photometric observations of 3691 Bede's thermal emission at 2 phase angles (27&43 deg 2015-03-19 & 04-13), in addition to WISE data (33deg 2010-05-27, Mainzer+2011). Observing geometries differ by solar phase angles and by moderate changes in heliocentric distance (e.g., further distances produce somewhat cooler surface temperatures). With the NEATM model and for a constant IR beaming parameter (eta=constant), there is a family of solutions for (diameter, pv, G, eta) where G is the slope parameter from the H-G Relation. NEATM models employing Pravec+2012's choice of G=0.43, produce D=1.8 km and pv˜0.4, given that G=0.43 is assumed from studies of main belt asteroids (Warner+2009). We present an analysis of the light curve of 3691 Bede to constrain G from observations. We also investigate fitting thermophysical models (TPM, Rozitis+11) to constrain the coupled parameters of thermal inertia (Gamma) and surface roughness, which in turn affect diameter and pv. Surface composition can be related to pv. This study focuses on understanding and characterizing the dependency of parameters with the aim of constraining diameter, pv and thermal inertia for 3691 Bede.

  11. Characterization of the high-albedo NEA 3691 Bede

    NASA Astrophysics Data System (ADS)

    Wooden, Diane H.; Lederer, Susan M.; Jehin, Emmanuel; Rozitis, Benjamin; Jefferson, Jeffrey D.; Nelson, Tyler W.; Dotson, Jessie L.; Ryan, Erin L.; Howell, Ellen S.; Fernandez, Yanga R.; Lovell, Amy J.; Woodward, Charles E.; Harker, David Emerson

    2016-10-01

    Characterization of NEAs provides important inputs to models for atmospheric entry, risk assessment and mitigation. Diameter is a key parameter because diameter translates to kinetic energy in atmospheric entry. Diameters can be derived from the absolute magnitude, H(PA=0deg), and from thermal modeling of observed IR fluxes. For both methods, the albedo (pv) is important - high pv surfaces have cooler temperatures, larger diameters for a given Hmag, and shallower phase curves (larger slope parameter G). Thermal model parameters are coupled, however, so that a higher thermal inertia also results in a cooler surface temperature. Multiple parameters contribute to constraining the diameter.Observations made at multiple observing geometries can contribute to understanding the relationships between and potentially breaking some of the degeneracies between parameters. We present data and analyses on NEA 3691 Bede with the aim of best constraining the diameter and pv from a combination of thermal modeling and light curve analyses. We employ our UKIRT+Michelle mid-IR photometric observations of 3691 Bede's thermal emission at 2 phase angles (27&43 deg 2015-03-19 & 04-13), in addition to WISE data (33deg 2010-05-27, Mainzer+2011).Observing geometries differ by solar phase angles and by moderate changes in heliocentric distance (e.g., further distances produce somewhat cooler surface temperatures). With the NEATM model and for a constant IR beaming parameter (eta=constant), there is a family of solutions for (diameter, pv, G, eta) where G is the slope parameter from the H-G Relation. NEATM models employing Pravec+2012's choice of G=0.43, produce D=1.8 km and pv≈0.4, given that G=0.43 is assumed from studies of main belt asteroids (Warner+2009). We present an analysis of the light curve of 3691 Bede to constrain G from observations. We also investigate fitting thermophysical models (TPM, Rozitis+11) to constrain the coupled parameters of thermal inertia (Gamma) and surface roughness, which in turn affect diameter and pv. Surface composition can be related to pv. This study focuses on understanding and characterizing the dependency of parameters with the aim of constraining diameter, pv and thermal inertia for 3691 Bede.

  12. 40 CFR 61.24 - Annual reporting requirements.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ..., including their location, diameter, flow rate, effluent temperature and release height. (5) A description of...) Distances from the points of release to the nearest residence, school, business or office and the nearest...

  13. Deep proton tunneling in the electronically adiabatic and non-adiabatic limits: Comparison of the quantum and classical treatment of donor-acceptor motion in a protein environment

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Benabbas, Abdelkrim; Salna, Bridget; Sage, J. Timothy

    2015-03-21

    Analytical models describing the temperature dependence of the deep tunneling rate, useful for proton, hydrogen, or hydride transfer in proteins, are developed and compared. Electronically adiabatic and non-adiabatic expressions are presented where the donor-acceptor (D-A) motion is treated either as a quantized vibration or as a classical “gating” distribution. We stress the importance of fitting experimental data on an absolute scale in the electronically adiabatic limit, which normally applies to these reactions, and find that vibrationally enhanced deep tunneling takes place on sub-ns timescales at room temperature for typical H-bonding distances. As noted previously, a small room temperature kinetic isotopemore » effect (KIE) does not eliminate deep tunneling as a major transport channel. The quantum approach focuses on the vibrational sub-space composed of the D-A and hydrogen atom motions, where hydrogen bonding and protein restoring forces quantize the D-A vibration. A Duschinsky rotation is mandated between the normal modes of the reactant and product states and the rotation angle depends on the tunneling particle mass. This tunnel-mass dependent rotation contributes substantially to the KIE and its temperature dependence. The effect of the Duschinsky rotation is solved exactly to find the rate in the electronically non-adiabatic limit and compared to the Born-Oppenheimer (B-O) approximation approach. The B-O approximation is employed to find the rate in the electronically adiabatic limit, where we explore both harmonic and quartic double-well potentials for the hydrogen atom bound states. Both the electronically adiabatic and non-adiabatic rates are found to diverge at high temperature unless the proton coupling includes the often neglected quadratic term in the D-A displacement from equilibrium. A new expression is presented for the electronically adiabatic tunnel rate in the classical limit for D-A motion that should be useful to experimentalists working near room temperature. This expression also holds when a broad protein conformational distribution of D-A equilibrium distances dominates the spread of the D-A vibrational wavefunction.« less

  14. Deep proton tunneling in the electronically adiabatic and non-adiabatic limits: comparison of the quantum and classical treatment of donor-acceptor motion in a protein environment.

    PubMed

    Benabbas, Abdelkrim; Salna, Bridget; Sage, J Timothy; Champion, Paul M

    2015-03-21

    Analytical models describing the temperature dependence of the deep tunneling rate, useful for proton, hydrogen, or hydride transfer in proteins, are developed and compared. Electronically adiabatic and non-adiabatic expressions are presented where the donor-acceptor (D-A) motion is treated either as a quantized vibration or as a classical "gating" distribution. We stress the importance of fitting experimental data on an absolute scale in the electronically adiabatic limit, which normally applies to these reactions, and find that vibrationally enhanced deep tunneling takes place on sub-ns timescales at room temperature for typical H-bonding distances. As noted previously, a small room temperature kinetic isotope effect (KIE) does not eliminate deep tunneling as a major transport channel. The quantum approach focuses on the vibrational sub-space composed of the D-A and hydrogen atom motions, where hydrogen bonding and protein restoring forces quantize the D-A vibration. A Duschinsky rotation is mandated between the normal modes of the reactant and product states and the rotation angle depends on the tunneling particle mass. This tunnel-mass dependent rotation contributes substantially to the KIE and its temperature dependence. The effect of the Duschinsky rotation is solved exactly to find the rate in the electronically non-adiabatic limit and compared to the Born-Oppenheimer (B-O) approximation approach. The B-O approximation is employed to find the rate in the electronically adiabatic limit, where we explore both harmonic and quartic double-well potentials for the hydrogen atom bound states. Both the electronically adiabatic and non-adiabatic rates are found to diverge at high temperature unless the proton coupling includes the often neglected quadratic term in the D-A displacement from equilibrium. A new expression is presented for the electronically adiabatic tunnel rate in the classical limit for D-A motion that should be useful to experimentalists working near room temperature. This expression also holds when a broad protein conformational distribution of D-A equilibrium distances dominates the spread of the D-A vibrational wavefunction.

  15. The clustering of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey DR14 quasar sample: measurement of the growth rate of structure from the anisotropic correlation function between redshift 0.8 and 2.2

    NASA Astrophysics Data System (ADS)

    Zarrouk, Pauline; Burtin, Etienne; Gil-Marín, Héctor; Ross, Ashley J.; Tojeiro, Rita; Pâris, Isabelle; Dawson, Kyle S.; Myers, Adam D.; Percival, Will J.; Chuang, Chia-Hsun; Zhao, Gong-Bo; Bautista, Julian; Comparat, Johan; González-Pérez, Violeta; Habib, Salman; Heitmann, Katrin; Hou, Jiamin; Laurent, Pierre; Le Goff, Jean-Marc; Prada, Francisco; Rodríguez-Torres, Sergio A.; Rossi, Graziano; Ruggeri, Rossana; Sánchez, Ariel G.; Schneider, Donald P.; Tinker, Jeremy L.; Wang, Yuting; Yèche, Christophe; Baumgarten, Falk; Brownstein, Joel R.; de la Torre, Sylvain; du Mas des Bourboux, Hélion; Kneib, Jean-Paul; Mariappan, Vivek; Palanque-Delabrouille, Nathalie; Peacock, John; Petitjean, Patrick; Seo, Hee-Jong; Zhao, Cheng

    2018-06-01

    We present the clustering measurements of quasars in configuration space based on the Data Release 14 (DR14) of the Sloan Digital Sky Survey IV extended Baryon Oscillation Spectroscopic Survey (eBOSS). This data set includes 148 659 quasars spread over the redshift range 0.8 ≤ z ≤ 2.2 and spanning 2112.9 deg2. We use the Convolution Lagrangian Perturbation Theory approach with a Gaussian Streaming model for the redshift space distortions of the correlation function and demonstrate its applicability for dark matter haloes hosting eBOSS quasar tracers. At the effective redshift zeff = 1.52, we measure the linear growth rate of structure fσ8(zeff) = 0.426 ± 0.077, the expansion rate H(z_eff)= 159^{+12}_{-13}(rs^fid/r_s) {{}km s}^{-1} Mpc^{-1}, and the angular diameter distance DA(z_eff)=1850^{+90}_{-115} (r_s/rs^fid) {}Mpc, where rs is the sound horizon at the end of the baryon drag epoch and rs^fid is its value in the fiducial cosmology. The quoted uncertainties include both systematic and statistical contributions. The results on the evolution of distances are consistent with the predictions of flat Λ-cold dark matter cosmology with Planck parameters, and the measurement of fσ8 extends the validity of General Relativity to higher redshifts (z > 1). This paper is released with companion papers using the same sample. The results on the cosmological parameters of the studies are found to be in very good agreement, providing clear evidence of the complementarity and of the robustness of the first full-shape clustering measurements with the eBOSS DR14 quasar sample.

  16. Coendutermes tucum Fontes (Isoptera, Termitidae, Nasutitermitinae): description of the imago caste and additional notes.

    PubMed

    Cuezzo, Carolina

    2016-12-09

    Coendutermes Fontes, 1985 is a monotypic South American termite genus. Coendutermes tucum Fontes, 1985, was described based on morphological characters from soldiers and workers collected in Mato Grosso, Brazil, and Jodensavanne, Suriname. Herein, I describe the imago caste of C. tucum for the first time with additional notes on soldiers, workers, and new distributional records. The studied material is deposited at the Museu de Zoologia da Universidade de São Paulo, São Paulo, Brazil (MZUSP). I use the terminology of Fontes (1987) to describe worker mandibles, and that of Noirot (2001) for the different parts of the digestive tube of workers. I measured the imagoes morphometric characters following Roonwal (1970): LH, length of head capsule (9); WH, width of head capsule without eyes (18); OF, occipito-fontanelle distance (23); DE, diameter of eye (48); LO, length of ocellus (55); WO, width of ocellus (56); EOD, eye-ocellus distance (57); LP, length of pronotum (65); WP, width of pronotum (68); LT, length of hind tibia (85). I took photographs of all castes with a stereomicroscope (Leica M205C) attached to a video camera (Leica DFC295) and images of gizzard and enteric valve under a microscope (Leica DM750B) attached to a video camera (Leica ICC50HD), then I combined the stacks of images with the software Leica LAS EZ 2.0 or Helicon Focus 5.2.11 X64. For the scanning electron micrographs (SEM), one soldier was dried to critical point while directly mounted on a stub with double face adhesive tape, then coated with gold and photographed with the SEM (Zeiss LEO 440 ®).

  17. Contact Geometry and Distribution of Plasma Generated in the Vicinity of Sliding Contact

    NASA Astrophysics Data System (ADS)

    Nakayama, Keiji

    2007-09-01

    The effect of the geometry of the smaller sliding partner on plasma (triboplasma) generation has been investigated as a function of the tip radius of a diamond pin, which slides against a single crystal sapphire disk under atmospheric dry air pressure. It was found that the diameter and the total intensity of the circular triboplasma increase parabolically with an increase in the tip radius of the pin under constant normal force and sliding velocity. The plasma is most intense at the crossing point of the plasma ring and the frictional track in the plasma circle. The gap distance at the crossing point is independent of the tip radius. The ring diameter increases with an increase in the tip radius, keeping the gap distance constant and obeying Paschen’s law of gas discharge.

  18. High-precision infra-red stellar interferometry

    NASA Astrophysics Data System (ADS)

    Lane, Benjamin F.

    2003-08-01

    This dissertation describes work performed at the Palomar Testbed Interferometer (PTI) during 1998 2002. Using PTI, we developed a method to measure stellar angular diameters in the 1 3 milli-arcsecond range with a precision of better than 5%. Such diameter measurements were used to measure the mass-radius relations of several lower main sequence stars and hence verify model predictions for these stars. In addition, by measuring the changes in Cepheid angular diameters during the pulsational cycle and applying a Baade-Wesselink analysis we are able to derive the distances to two galactic Cepheids (η Aql & ζ Gem) with a precision of ˜10%; such distance determinations provide an independent calibration of the Cepheid period- luminosity relations that underpin current estimates of cosmic distance scales. Second, we used PTI and the adaptive optics facility at the Keck Telescope on Mauna Kea to resolve the low mass binary systems BY Dra and GJ 569B, resulting in dynamical mass determinations for these systems. GJ 569B most likely contains at least one sub-stellar component, and as such represents the first dynamical mass determination of a brown dwarf. Finally, a new observing technique, dual star phase referencing, was developed and demonstrated at PTI. Phase referencing allows interferometric observations of stars previously too faint to observe, and is a prerequisite for large-scale interferometric astrometry programs such as the one planned for the Keck Interferometer; interferometric astrometry is a promising technique for the study of extra-solar planetary systems, particularly ones with long-period planets.

  19. Quantification of annular dilatation and papillary muscle separation in functional mitral regurgitation: role of anterior mitral leaflet length as reference.

    PubMed

    Jorapur, Vinod; Voudouris, Apostolos; Lucariello, Richard J

    2005-07-01

    We hypothesized that anterior mitral leaflet length (ALL) does not differ significantly between normal subjects and patients with functional mitral regurgitation (FMR) and hence may be used as a reference measurement to quantify annular dilatation and papillary muscle separation. We prospectively studied 50 controls, 15 patients with systolic left ventricular dysfunction (LVD) with significant FMR, and 15 patients with LVD without significant FMR. Significant MR was defined as an effective regurgitant orifice area > or = 0.2 cm2 as measured by the flow convergence method. Annular diameter, interpapillary distance, and ALL were measured, and the following ratios were derived: annular diameter indexed to ALL (ADI) and interpapillary distance indexed to ALL (IPDI). There was no significant difference in ALL among the three groups. The mean ADI was 1.26 times controls in patients with LVD without significant FMR compared to 1.33 times controls in patients with LVD with significant FMR (P = 0.06, no significant difference between groups). The mean IPDI was 1.42 times controls in patients with LVD without significant FMR compared to 2.1 times controls in patients with LVD with significant FMR (P < 0.0001, significant difference between groups). There was no significant difference in ALL between controls and patients with LVD. ALL can be used as a reference measurement to quantify annular dilatation and papillary muscle separation in patients with FMR. Interpapillary distance but not annular diameter indexed to ALL correlates with severity of FMR.

  20. Light scattering in optical CT scanning of Presage dosimeters

    NASA Astrophysics Data System (ADS)

    Xu, Y.; Adamovics, J.; Cheeseborough, J. C.; Chao, K. S.; Wuu, C. S.

    2010-11-01

    The intensity of the scattered light from the Presage dosimeters was measured using a Thorlabs PM100D optical power meter (Thorlabs Inc, Newton, NJ) with an optical sensor of 1 mm diameter sensitive area. Five Presage dosimeters were made as cylinders of 15.2 cm, 10 cm, 4 cm diameters and irradiated with 6 MV photons using a Varian Clinac 2100EX. Each dosimeter was put into the scanning tank of an OCTOPUS" optical CT scanner (MGS Research Inc, Madison, CT) filled with a refractive index matching liquid. A laser diode was positioned at one side of the water tank to generate a stationary laser beam of 0.8 mm width. On the other side of the tank, an in-house manufactured positioning system was used to move the optical sensor in the direction perpendicular to the outgoing laser beam from the dosimeters at an increment of 1 mm. The amount of scattered photons was found to be more than 1% of the primary light signal within 2 mm from the laser beam but decreases sharply with increasing off-axis distance. The intensity of the scattered light increases with increasing light attenuations and/or absorptions in the dosimeters. The scattered light at the same off-axis distance was weaker for dosimeters of larger diameters and for larger detector-to-dosimeter distances. Methods for minimizing the effect of the light scattering in different types of optical CT scanners are discussed.

  1. CORS BAADE-WESSELINK DISTANCE TO THE LMC NGC 1866 BLUE POPULOUS CLUSTER

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Molinaro, R.; Ripepi, V.; Marconi, M.

    2012-03-20

    We used optical, near-infrared photometry, and radial velocity data for a sample of 11 Cepheids belonging to the young LMC blue populous cluster NGC 1866 to estimate their radii and distances on the basis of the CORS Baade-Wesselink method. This technique, based on an accurate calibration of surface brightness as a function of (U - B), (V - K) colors, allows us to estimate, simultaneously, the linear radius and the angular diameter of Cepheid variables, and consequently to derive their distance. A rigorous error estimate on radii and distances was derived by using Monte Carlo simulations. Our analysis gives amore » distance modulus for NGC 1866 of 18.51 {+-} 0.03 mag, which is in agreement with several independent results.« less

  2. Tellurium-nanowire-coated glassy carbon electrodes for selective and sensitive detection of dopamine.

    PubMed

    Tsai, Hsiang-Yu; Lin, Zong-Hong; Chang, Huan-Tsung

    2012-05-15

    Tellurium-nanowire-coated glassy carbon electrodes (TNGCEs) have been fabricated and employed for selective and sensitive detection of dopamine (DA). TNGCEs were prepared by direct deposition of tellurium nanowires, 600 ± 150 nm in length and 16 ± 3 nm in diameter, onto glassy carbon electrodes, which were further coated with Nafion to improve their selectivity and stability. Compared to the GCE, the TNGCE is more electroactive (by approximately 1.9-fold) for DA, and its selectivity toward DA over ascorbic acid (AA) and uric acid (UA) is also greater. By applying differential pulse voltammetry, at a signal-to-noise ratio of 3, the TNGCE provides a limit of detection of 1 nM for DA in the presence of 0.5mM AA and UA. Linearity (R(2)=0.9955) of the oxidation current at 0.19 V against the concentration of DA is found over the range 5 nM-1 μM. TNGCEs have been applied to determine the concentration of dopamine to be 0.59 ± 0.07 μM in PC12 cells. Copyright © 2012 Elsevier B.V. All rights reserved.

  3. Biometry of the hypospadic penis after hormone therapy (testosterone and estrogen): A randomized, double-blind controlled trial.

    PubMed

    Paiva, Kelly Christina de Castro; Bastos, André Netto; Miana, Laura Pimenta; Barros, Eveline de Souza; Ramos, Plínio Santos; Miranda, Lara Meneguelli; Faria, Natália Maia; Avarese de Figueiredo, André; de Bessa, José; Netto, José Murillo B

    2016-08-01

    The use of preoperative hormonal stimulation before hypospadias surgery aims to increase penile size and achieve better surgical results; however, the rules are not clear in the literature. We evaluated the effects of topical testosterone and estrogen in the hypospadic penis regarding biometric measures, side effects, and serum hormonal levels. To our knowledge, this is the first study using estradiol prior to hypospadias surgery. Sixty-nine children with hypospadias were randomly divided into three study groups: a control group (CG) of 17 children given placebo cream; a testosterone group (TG) of 28 children who used 1% testosterone propionate; and an estradiol group (EG) of 24 children using 0.01% estradiol. All subjects applied the topical ointment on the entire penis, twice daily for 30 days before surgical correction. Biometric evaluation of the penis included penile length and diameter, glans diameter, distance from the urethral meatus to the tip, and the width of the urethral plate. These measurements as well as serum hormone level, and side effects were evaluated prior to hormone use, and 30 and 90 days after. After 30 days an increase in penile diameter and length and diameter of the glans were observed in TG (p < 0.05). The width of the urethral plate and distance from meatus to the tip increased in TG, although not significantly. The most frequent side effects were appearance of pubic hair and darkening of the genital skin, mainly in TG, but these were transient and disappeared after 90 days of treatment. No significant variations were seen in serum hormonal levels (Table). As in previous studies, an increase in penile length and diameter, and glans diameter was observed with the use of testosterone. Proximal urethral plate width and distance from the meatus to the tip of the penis had a tendency to increase also in TG. Estradiol did not change biometric measure of the penis. Few side effects occurred after both hormones, and any that did improved after 90 days follow-up and did not change hormone serum levels. Preoperative use of topical testosterone increases penile size, diameter of the penis and glans. The use of estradiol does not change penile biometry. Side effects occur mainly with the use of testosterone and are transient. No significant and persistent hormonal changes were observed. Copyright © 2016 Journal of Pediatric Urology Company. Published by Elsevier Ltd. All rights reserved.

  4. The Earth and Moon As Seen by 2001 Mars Odyssey's Thermal Emission Imaging System

    NASA Technical Reports Server (NTRS)

    2001-01-01

    2001 Mars Odyssey's Thermal Emission Imaging System (THEMIS) took this portrait of the Earth and its companion Moon, using the infrared camera, one of two cameras in the instrument. It was taken at a distance of 3,563,735 kilometers (more than 2 million miles) on April 19, 2001 as the 2001 Mars Odyssey spacecraft left the Earth. From this distance and perspective the camera was able to acquire an image that directly shows the true distance from the Earth to the Moon. The Earth's diameter is about 12,750 km, and the distance from the Earth to the Moon is about 385,000 km, corresponding to 30 Earth diameters. The dark region seen on Earth in the infrared temperature image is the cold south pole, with a temperature of minus 50 degrees Celsius (minus 58 degrees Fahrenheit). The small bright region above it is warm Australia. This image was acquired using the 9.1 um infrared filter, one of nine filters that the instrument will use to map the mineral composition and temperature of the martian surface. From this great distance, each picture element (pixel) in the image corresponds to a region 900 by 900 kilometers or greater in size or about size of the state of Texas. Once Odyssey reaches Mars orbit each infrared pixel will cover a region only 100 by 100 meters on the surface, about the size of a major league baseball field.

  5. The effect of nozzle-exit-channel shape on resultant fiber diameter in melt-electrospinning

    NASA Astrophysics Data System (ADS)

    Esmaeilirad, Ahmad; Ko, Junghyuk; Rukosuyev, Maxym V.; Lee, Jason K.; Lee, Patrick C.; Jun, Martin B. G.

    2017-01-01

    In recent decades, electrospinning using a molten poly (ε-caprolactone) resin has gained attention for creating fibrous tissue scaffolds. The topography and diameter control of such electrospun microfibers is an important issue for their different applications in tissue engineering. Charge density, initial nozzle-exit-channel cross-sectional area, nozzle to collector distance, viscosity, and processing temperature are the most important input parameters that affect the final electrospun fiber diameters. In this paper we will show that the effect of nozzle-exit-channel shape is as important as the other effective parameters in a resultant fiber diameter. However, to the best of our knowledge, the effect of nozzle-exit-channel shapes on a resultant fiber diameter have not been studied before. Comparing rectangular and circular nozzles with almost the same exit-channel cross-sectional areas in a similar processing condition showed that using a rectangular nozzle resulted in decreasing final fiber diameter up to 50%. Furthermore, the effect of processing temperature on the final fiber topography was investigated.

  6. A numerical study on the effect of various combustion bowl parameters on the performance, combustion, and emission behavior on a single cylinder diesel engine.

    PubMed

    Balasubramanian, Dhinesh; Sokkalingam Arumugam, Sabari Rajan; Subramani, Lingesan; Joshua Stephen Chellakumar, Isaac JoshuaRamesh Lalvani; Mani, Annamalai

    2018-01-01

    A numerical study was carried out to study the effect of various combustion bowl parameters on the performance behavior, combustion characteristics, and emission magnitude on a single cylinder diesel engine. A base combustion bowl and 11 different combustion bowls were created by varying the aspect ratio, reentrancy ratio, and bore to bowl ratio. The study was carried out at engine rated speed and a full throttle performance condition, without altering the compression ratio. The results revealed that the combustion bowl parameters could have a huge impact on the performance behavior, combustion characteristics, and emission magnitude of the engine. The bowl parameters, namely throat diameter and toroidal radius, played a crucial role in determining the performance behavior of the combustion bowls. It was observed that the combustion bowl parameters, namely central pip distance, throat diameter, and bowl depth, also could have an impact on the combustion characteristics. And throat diameter and toroidal radius, central pip distance, and toroidal corner radius could have a consequent effect on the emission magnitude of the engine. Of the different combustion bowls tested, combustion bowl 4 was preferable to others owing to the superior performance of 3% of higher indicated mean effective pressure and lower fuel consumption. Interestingly, trade-off for NO x emission was higher only by 2.85% compared with the base bowl. The sensitivity analysis proved that bowl depth, bowl diameter, toroidal radius, and throat diameter played a vital role in the fuel consumption parameter and emission characteristics even at the manufacturing tolerance variations.

  7. Assembly of flammutoxin, a cytolytic protein from the edible mushroom Flammulina velutipes, into a pore-forming ring-shaped oligomer on the target cell.

    PubMed

    Tomita, T; Ishikawa, D; Noguchi, T; Katayama, E; Hashimoto, Y

    1998-07-01

    Flammutoxin has been previously isolated as a cardiotoxic and cytolytic polypeptide of 22 or 32 kDa from the fruiting bodies of the edible mushroom Flammulina velutipes. In the present study, we purified flammutoxin as a single haemolytic protein of 31 kDa and studied the mode of its cytolytic action. (1) Flammutoxin caused efflux of potassium ions from human erythrocytes and swelling of the cells before haemolysis. (2) Flammutoxin did not lyse human erythrocytes in the presence of non-electrolytes with hydrodynamic diameters of >5.0 nm, although it caused leakage of potassium ions and swelling of the cells under the same conditions. (3) Experiments including solubilization of cell-bound toxin with 2% (w/v) SDS at 20 degrees C and subsequent Western immunoblots showed that flammutoxin formed a band corresponding to 180 kDa under the conditions where it lysed erythrocytes. (4) Electron microscopy of flammutoxin-treated human erythrocytes revealed the presence of a ring-shaped structure with outer and inner diameters of 10 and 5 nm, respectively, on the cells. (5) A ring-shaped toxin oligomer of the same dimensions was solubilized from the toxin-treated human erythrocytes with 2% (w/v) SDS at 20 degrees C and isolated by a sucrose-gradient ultracentrifugation. These data indicated that flammutoxin assembles into a ring-shaped oligomer possessing a hydrophilic pore of 4-5 nm on target cells.

  8. Temperature-controlled cross-linking of silver nanoparticles with diels-alder reaction and its application on antibacterial property

    NASA Astrophysics Data System (ADS)

    Liu, Lian; Yang, Pengfei; Li, Junying; Zhang, Zhiliang; Yu, Xi; Lu, Ling

    2017-05-01

    Sliver nanoparticles (AgNPs) were synthesized and functionalized with furan group on their surface, followed by the reverse Diels-Alder (DA) reaction with bismaleimide to vary the particle size, so as to give different antibacterial activities. These nanoparticles were characterized using Scanning Electron Microscope (SEM), X-Ray Diffraction (XRD), Ultraviolet-Visible (UV-vis), Nanoparticle Size Analyzer and X-Ray Photoelectron Spectroscopy (XPS). It was found that the cross-linking reaction with bismaleimide had a great effect on the size of AgNPs. The size of the AgNPs could be controlled by the temperature of DA/r-DA equilibrium. The antibacterial activity was assessed using the inhibition zone diameter by introducing the particles into a media containing Escherichia coli, Listeria monocytogenes, and Staphylococcus aureus, respectively. It was found that these particles were effective bactericides. Furthermore, the antibacterial activity of the nanoparticles decreased orderly as the particle size enlarged.

  9. [First experience in the thyroid and parathyroid surgery using the da Vinci® system].

    PubMed

    Al Kadah, B; Siemer, S; Schick, B

    2014-01-01

    Endoscopic surgery for the treatment of thyroid and parathyroid pathologies is gaining increasing attention. The da Vinci® system has been already widely used in different fields of medicine including recently thyroid and parathyroid surgery. Herein we report our first experiences in endoscopic surgery of thyroid and parathyroid pathologies using the da Vinci® system. 8 patients presenting with struma nodosa in 6 cases and parathyroid adenomas in 2 cases have been treated using the da Vinci® system at the ENT department of Homburg/Saar University. The skin incision to introduce the instruments with the da Vinci® system were axilar or at the lateral segment of the clavicle. The neurovascular structures like inferior laryngeal nerve as well as the pathologies were clearly 3-dimensional visualized in all 8 cases. No paralysis of the vocal cord was observed. All patients had in histological examination a benign pathology. The endoscopic surgery of the thyroid and parathyroid gland can be performed using the da Vinci® system and offers an excellent, intraoperative, 3-dimensional visualization of the neurovascular structures. Additionally the da Vinci® system enables skin incisions within considerable distance from the thyroid and parathyroid gland. © Georg Thieme Verlag KG Stuttgart · New York.

  10. The genome sequence of Agrotis segetum granulovirus, isolate AgseGV-DA, reveals a new Betabaculovirus species of a slow killing granulovirus.

    PubMed

    Gueli Alletti, Gianpiero; Eigenbrod, Marina; Carstens, Eric B; Kleespies, Regina G; Jehle, Johannes A

    2017-06-01

    The European isolate Agrotis segetum granulovirus DA (AgseGV-DA) is a slow killing, type I granulovirus due to low dose-mortality responses within seven days post infection and a tissue tropism of infection restricted solely to the fat body of infected Agrotis segetum host larvae. The genome of AgseGV-DA was completely sequenced and compared to the whole genome sequences of the Chinese isolates AgseGV-XJ and AgseGV-L1. All three isolates share highly conserved genomes. The AgseGV-DA genome is 131,557bp in length and encodes for 149 putative open reading frames, including 37 baculovirus core genes and the per os infectivity factor ac110. Comprehensive investigations of repeat regions identified one putative non-hr like origin of replication in AgseGV-DA. Phylogenetic analysis based on concatenated amino acid alignments of 37 baculovirus core genes as well as pairwise distances based on the nucleotide alignments of partial granulin, lef-8 and lef-9 sequences with deposited betabaculoviruses confirmed AgseGV-DA, AgseGV-XJ and AgseGV-L1 as representative isolates of the same Betabaculovirus species. AgseGV encodes for a distinct putative enhancin, distantly related to enhancins from other granuloviruses. Copyright © 2017. Published by Elsevier Inc.

  11. Numerical simulation of scouring-deposition variations caused by rainfall-induced landslides in the upstream of Zengwun River, Taiwan

    NASA Astrophysics Data System (ADS)

    Lee, Ming-Hsi; Liao, Yi-Wen; Tsai, Kuang-Jung

    2017-04-01

    In recent years, the increasing sediment disasters of severe rainfall-induced landslides on human lives and lifeline facilities worldwide have advanced the necessity to find out both economically acceptable and useful techniques to predict the occurrence and destructive power of the disasters. In August 2009, Typhoon Morakot brought a large amount of rainfall with both high intensity and long duration to a vast area of Taiwan. Unfortunately, this resulted in a catastrophic landslide in watershed of Zengwun-River reservoir, southern Taiwan. Meanwhile, large amounts of landslides were formed in the upstream of Zengwun River. The major scope of this study is to apply numerical model to simulate the scouring-deposition variations caused by rainfall-induced landslides that occurred in the upstream of Zengwun River during Typhoon Morakot. This study proposed the relation diagrams of the intermediate diameter (d50), recurrence interval (T) and scouring-deposition depth (D), and applied the diagrams to understand the impacts of the scouring-deposition variations on the structures for water and soil conservation and their measurements. Based on the simulation of scouring-deposition variation at the Da-Bu dam and Da-Bang dam, this study also discussed the scouring-deposition variations of different sections under different scenarios (including flow rate, intermediate diameters and structures). In summary, the result suggested that the diagrams of the intermediate diameter, recurrence interval and scouring-deposition depth could be used as the reference for designing the check dams, ground sills and lateral constructions.

  12. Shatter cones: (Mis)understood?

    PubMed Central

    Osinski, Gordon R.; Ferrière, Ludovic

    2016-01-01

    Meteorite impact craters are one of the most common geological features in the solar system. An impact event is a near-instantaneous process that releases a huge amount of energy over a very small region on a planetary surface. This results in characteristic changes in the target rocks, from vaporization and melting to solid-state effects, such as fracturing and shock metamorphism. Shatter cones are distinctive striated conical fractures that are considered unequivocal evidence of impact events. They are one of the most used and trusted shock-metamorphic effects for the recognition of meteorite impact structures. Despite this, there is still considerable debate regarding their formation. We show that shatter cones are present in several stratigraphic settings within and around impact structures. Together with the occurrence of complete and “double” cones, our observations are most consistent with shatter cone formation due to tensional stresses generated by scattering of the shock wave due to heterogeneities in the rock. On the basis of field mapping, we derive the relationship Dsc = 0.4 Da, where Dsc is the maximum spatial extent of in situ shatter cones, and Da is the apparent crater diameter. This provides an important, new, more accurate method to estimate the apparent diameter of eroded complex craters on Earth. We have reestimated the diameter of eight well-known impact craters as part of this study. Finally, we suggest that shatter cones may reduce the strength of the target, thus aiding crater collapse, and that their distribution in central uplifts also records the obliquity of impact. PMID:27532050

  13. Relation between N-terminal pro-brain natriuretic peptide levels and response to enhanced external counterpulsation in chronic angina pectoris.

    PubMed

    Sahlén, Anders; Wu, Eline; Rück, Andreas; Hagerman, Inger; Förstedt, Gunilla; Sylvén, Christer; Berglund, Margareta; Jernberg, Tomas

    2014-01-01

    Although enhanced external counterpulsation (EECP) provides symptom reduction in many patients with severe angina pectoris, one-quarter of patients fail to respond. Earlier reports have not clearly established whether and how EECP responders may be identified pre-hoc. We hypothesized that clinical and biochemical data may be used to predict EECP response. We explored a database of n=53 patients who had undergone clinically indicated EECP during 35 1-h sessions in our unit (65±7 years; 49 male), and sought to clarify which factors are predictive of response. Efficiency of counterpulsation was measured as the diastolic augmentation (DA) ratio, and was recorded both at beginning and end of the EECP treatment course. An increase in 6-min walk (6MW) distance of 5% was indicative of clinical response. Response occurred in 28 patients (53%; nonresponse in n=25, 47%). Responders had shorter baseline 6MW distance (377±81 vs. 445±62 m; P<0.01), lower left ventricular ejection fraction (48±9 vs. 54±8%; P<0.05), frequently had an increase in DA ratio during the EECP treatment course (23/28 vs. 5/28 with unchanged or decreased DA ratio; P<0.05), and higher levels of N-terminal pro-brain natriuretic peptide [NT-proBNP; 256 (123-547) vs. 62 (26-444) ng/l, P<0.01]. In multivariate logistic regression, response was independently predicted by baseline 6MW distance and baseline NT-proBNP levels (P<0.05 for both; model sensitivity: 82%, specificity: 72%, accuracy: 79%). There is larger clinical benefit of EECP in patients with greater functional impairment and higher levels of NT-proBNP.

  14. Optical Coherence Tomography Scan Circle Location and Mean Retinal Nerve Fiber Layer Measurement Variability

    PubMed Central

    Gabriele, Michelle L.; Ishikawa, Hiroshi; Wollstein, Gadi; Bilonick, Richard A.; Townsend, Kelly A.; Kagemann, Larry; Wojtkowski, Maciej; Srinivasan, Vivek J.; Fujimoto, James G.; Duker, Jay S.; Schuman, Joel S.

    2009-01-01

    PURPOSE To investigate the effect on optical coherence tomography (OCT) retinal nerve fiber layer (RNFL) thickness measurements of varying the standard 3.4-mm-diameter circle location. METHODS The optic nerve head (ONH) region of 17 eyes of 17 healthy subjects was imaged with high-speed, ultrahigh-resolution OCT (hsUHR-OCT; 501 × 180 axial scans covering a 6 × 6-mm area; scan time, 3.84 seconds) for a comprehensive sampling. This method allows for systematic simulation of the variable circle placement effect. RNFL thickness was measured on this three-dimensional dataset by using a custom-designed software program. RNFL thickness was resampled along a 3.4-mm-diameter circle centered on the ONH, then along 3.4-mm circles shifted horizontally (x-shift), vertically (y-shift) and diagonally up to ±500 µm (at 100-µm intervals). Linear mixed-effects models were used to determine RNFL thickness as a function of the scan circle shift. A model for the distance between the two thickest measurements along the RNFL thickness circular profile (peak distance) was also calculated. RESULTS RNFL thickness tended to decrease with both positive and negative x- and y-shifts. The range of shifts that caused a decrease greater than the variability inherent to the commercial device was greater in both nasal and temporal quadrants than in the superior and inferior ones. The model for peak distance demonstrated that as the scan moves nasally, the RNFL peak distance increases, and as the circle moves temporally, the distance decreases. Vertical shifts had a minimal effect on peak distance. CONCLUSIONS The location of the OCT scan circle affects RNFL thickness measurements. Accurate registration of OCT scans is essential for measurement reproducibility and longitudinal examination (ClinicalTrials.gov number, NCT00286637). PMID:18515577

  15. Establishment of a genetic transformation system for the marine pennate diatom Fistulifera sp. strain JPCC DA0580--a high triglyceride producer.

    PubMed

    Muto, Masaki; Fukuda, Yorikane; Nemoto, Michiko; Yoshino, Tomoko; Matsunaga, Tadashi; Tanaka, Tsuyoshi

    2013-02-01

    A genetic transformation system for the marine pennate diatom, Fistulifera sp. JPCC DA0580, was established using microparticle bombardment methods. Strain JPCC DA0580 has been recently identified as the highest triglyceride (60 % w/w) producer from a culture collection of 1,393 strains of marine microalgae, and it is expected to be a feasible source of biodiesel fuel. The transformation conditions for strain JPCC DA0580 were optimised using the green fluorescent protein gene (gfp) and the gene encoding neomycin phosphotransferase II (nptII). The most efficient rate of transformation was attained when tungsten particles (0.6 μm in diameter) were used for microparticle bombardment. The effect of endogenous and exogenous promoters on the expression of nptII was examined. Endogenous promoters were more efficient for obtaining transformants compared with exogenous promoters. Southern hybridisation analysis suggested that nptII integrated into the nuclear genome. This genetic manipulation technique should allow us to understand the mechanisms of high triglyceride accumulation in this strain, thereby contributing to improving BDF production.

  16. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kapp, O.H.; Mainwaring, M.G.; Vinogradov, S.N.

    A fraction of the extracellular hemoglobin of Lumbricus terrestris, obtained by gel filtration at neutral pH subsequent to dissociation either at pH 9.8 or at pH 4.0 or at pH 7.0 in 10 mM sodium phosphotungstate, consisting of the three subunits D1 (31 kDa), D2 (37 kDa) and T (50 kDa), produced two peaks when subjected to FPLC on a Superose 6 column at neutral pH. Peak I, eluting at a slightly greater volume than the native hemoglobin, consisted of reassociated hexagonal bilayer structures when examined by scanning transmission electron microscopy. The dimensions of the three reassociated hexagonal bilayer structuresmore » were 25 nm x 16 nm. Although the latter are smaller than the dimensions of the native hemoglobin, 30 nm x 20 nm, the diameter of the central cavity remained unchanged. Subtraction of the digitized and averaged images of the reassociated forms from those of the native hemoglobin suggested that the spatial localization of the fourth subunit, subunit M (16.7 kDa), was limited primarily to the periphery of the molecule.« less

  17. Spatial variation in deposition rate coefficients of an adhesion-deficient bacterial strain in quartz sand.

    PubMed

    Tong, Meiping; Camesano, Terri A; Johnson, William P

    2005-05-15

    The transport of bacterial strain DA001 was examined in packed quartz sand under a variety of environmentally relevant ionic strength and flow conditions. Under all conditions, the retained bacterial concentrations decreased with distance from the column inlet at a rate that was faster than loglinear, indicating that the deposition rate coefficient decreased with increasing transport distance. The hyperexponential retained profile contrasted againstthe nonmonotonic retained profiles that had been previously observed for this same bacterial strain in glass bead porous media, demonstrating that the form of deviation from log-linear behavior is highly sensitive to system conditions. The deposition rate constants in quartz sand were orders of magnitude below those expected from filtration theory, even in the absence of electrostatic energy barriers. The degree of hyperexponential deviation of the retained profiles from loglinear behavior did not decrease with increasing ionic strength in quartz sand. These observations demonstrate thatthe observed low adhesion and deviation from log-linear behavior was not driven by electrostatic repulsion. Measurements of the interaction forces between DA001 cells and the silicon nitride tip of an atomic force microscope (AFM) showed that the bacterium possesses surface polymers with an average equilibrium length of 59.8 nm. AFM adhesion force measurements revealed low adhesion affinities between silicon nitride and DA001 polymers with approximately 95% of adhesion forces having magnitudes < 0.8 nN. Steric repulsion due to surface polymers was apparently responsible for the low adhesion to silicon nitride, indicating that steric interactions from extracellular polymers controlled DA001 adhesion deficiency and deviation from log-linear behavior on quartz sand.

  18. Tomodensitometric survey of the distance between thoracic and abdominal vital organs and the wall according to BMI, abdominal diameter and gender: proposition of an indicative chart for the forensic activities.

    PubMed

    Venara, A; Gaudin, A; Lebigot, J; Airagnes, G; Hamel, J F; Jousset, N; Ridereau-Zins, C; Mauillon, D; Rouge-Maillart, C

    2013-06-10

    Forensic doctors are frequently asked by magistrates when dealing principally with knife wounds, about the depth of the blade which may have penetrated the victim's body. Without the use of imaging, it is often difficult to respond to this question, even in an approximate way. Knowledge of the various distances between organs and the skin wall would allow an assessment to be made of the minimum blade length required to obtain the injuries observed. The objective of this study is thus to determine average distances between the vital organs of the thorax and abdomen, and the skin wall, taking into account the person's body mass index (BMI). This is a prospective single-center study, carried out over a 2-month period at University Hospital in Angers. A sample of 200 people was studied. The inclusion criteria were as follows: all patients coming to the radiology department and the emergency department for an abdominal, thoracic or thoraco-abdominal scan with injection. The exclusion criteria included patients presenting a large lymphoma, a large abdominal or retroperitoneal tumor, a tumor in one of the organs targeted by our study and patients presenting ascites. The organs focused on were: the pericardium, pleura, aorta, liver, spleen, kidneys, abdominal aorta and femoral arteries. The shortest distance between the organ and the skin wall was noted. Median distances were calculated according to gender, abdominal diameter and BMI. We associated these values to propose an indicative chart which may be used by doctors in connection with their forensic activities. The problem of the depth of a wound is frequently exposed to the expert. Without a reliable tool, it is difficult to value and a personal interpretation is often done. Even if, in current days, tomodensitometry is frequently done in vivo or after death, measurement can be difficult because of the local conditions. We classified values according to the different factors of fat repartition (BMI, abdominal diameter, gender). These tables, collectively used, permit evaluation of the distance between wall and thoracic or abdominal vital organs. We suggest an indicative chart designed for forensic doctors in their professional life to help determine the minimum penetration length for a knife, which may wound a vital organ. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  19. Electrospinning of Polyvinylidene Fluoride and Polyetherimide From Mixed Solvents

    NASA Technical Reports Server (NTRS)

    Morgret, Leslie D.; Pawlowski, Kristin J.; Hinkley, Jeffrey A.

    2005-01-01

    Polyvinylidene fluoride and Ultem(TradeMark) polyetherimide were dissolved in 50/50 acetone/N,N dimethylformamide (DMF) and 80/20 tetrahydrofuran/DMF, respectively, and electrospun. Polymer solution concentrations and molecular weights were changed while other spinning parameters (voltage, distance, solution feed rate) were held constant. Fiber diameters in the resulting electrospun mats varied from 0.25 to 4.4 microns, increasing with polymer concentration and molecular weight; trends in diameter were compared with trends in viscosities and surface tensions of the spinning solutions.

  20. Effect of solenoidal magnetic field on drifting laser plasma

    NASA Astrophysics Data System (ADS)

    Takahashi, Kazumasa; Okamura, Masahiro; Sekine, Megumi; Cushing, Eric; Jandovitz, Peter

    2013-04-01

    An ion source for accelerators requires to provide a stable waveform with a certain pulse length appropriate to the application. The pulse length of laser ion source is easy to control because it is expected to be proportional to plasma drifting distance. However, current density decay is proportional to the cube of the drifting distance, so large current loss will occur under unconfined drift. We investigated the stability and current decay of a Nd:YAG laser generated copper plasma confined by a solenoidal field using a Faraday cup to measure the current waveform. It was found that the plasma was unstable at certain magnetic field strengths, so a baffle was introduced to limit the plasma diameter at injection and improve the stability. Magnetic field, solenoid length, and plasma diameter were varied in order to find the conditions that minimize current decay and maximize stability.

  1. Methodology to set up nozzle-to-substrate gap for high resolution electrohydrodynamic jet printing

    NASA Astrophysics Data System (ADS)

    Park, Jaehong; Park, Ji-Woon; Nasrabadi, Ali Mohamadi; Hwang, Jungho

    2016-09-01

    Several efforts have been made for the prediction of jet diameter in electrohydrodynamic jet printing; however, not much attention has been paid to the jet length, which is the distance from the cone apex to the location where the jet is unstable and is broken into atomized droplets. In this study, we measured both the cone length and the jet length using a high-speed camera, and measured the line pattern width with an optical microscope to investigate the effects of cone length and jet length on the pattern quality. Measurements were carried out with variations in nozzle diameter, flow rate, and applied voltage. The pattern width was theoretically predicted for the case when the nozzle-to-substrate distance was more than the cone length, and smaller than the summation of the cone and jet lengths (which is the case when there is no jet breakup).

  2. Two measures of performance in a peg-in-hole manipulation task with force feedback

    NASA Technical Reports Server (NTRS)

    Hill, J. W.

    1977-01-01

    The results are described from two manipulators on a peg-in-hole task, which is part of a continued effort to develop models for human performance with remote manipulators. Task difficulty is varied by changing the diameter of the peg to be inserted in a 50 mm diameter hole. An automatic measuring system records the distance between the tool being held by the manipulator and the receptacle into which it is to be inserted. The data from repeated insertions are processed by computer to determine task times, accumulated distances, and trajectories. Experiments with both the MA-11 cable-connected master-slave manipulator common to hot cell work and the MA-23 servo-controlled manipulator (with and without force feedback) are described. Comparison of these results with previous results of the Ames Manipulator shows that force feedback provides a consistent advantage.

  3. Thrust generation experiments on microwave rocket with a beam concentrator for long distance wireless power feeding

    NASA Astrophysics Data System (ADS)

    Fukunari, Masafumi; Yamaguchi, Toshikazu; Nakamura, Yusuke; Komurasaki, Kimiya; Oda, Yasuhisa; Kajiwara, Ken; Takahashi, Koji; Sakamoto, Keishi

    2018-04-01

    Experiments using a 1 MW-class gyrotron were conducted to examine a beamed energy propulsion rocket, a microwave rocket with a beam concentrator for long-distance wireless power feeding. The incident beam is transmitted from a beam transmission mirror system. The beam transmission mirror system expands the incident beam diameter to 240 mm to extend the Rayleigh length. The beam concentrator receives the beam and guides it into a 56-mm-diameter cylindrical thruster tube. Plasma ignition and ionization front propagation in the thruster were observed through an acrylic window using a fast-framing camera. Atmospheric air was used as a propellant. Thrust generation was achieved with the beam concentrator. The maximum thrust impulse was estimated as 71 mN s/pulse from a pressure history at the thrust wall at the input energy of 638 J/pulse. The corresponding momentum coupling coefficient, Cm was inferred as 204 N/MW.

  4. A Surface Energy Transfer Nanoruler for Measuring Binding Site Distances on Live Cell Surfaces

    PubMed Central

    Chen, Yan; O’Donoghue, Meghan B.; Huang, Yu-Fen; Kang, Huaizhi; Phillips, Joseph A.; Chen, Xiaolan; Estevez, M.-Carmen; Tan, Weihong

    2010-01-01

    Measuring distances at molecular length scales in living systems is a significant challenge. Methods like FRET have limitations due to short detection distances and strict orientations. Recently, surface energy transfer (SET) has been used in bulk solutions; however, it cannot be applied to living systems. Here, we have developed an SET nanoruler, using aptamer-gold-nanoparticle conjugates with different diameters, to monitor the distance between binding sites of a receptor on living cells. The nanoruler can measure separation distances well beyond the detection limit of FRET. Thus, for the first time, we have developed an effective SET nanoruler for live cells with long distance, easy construction, fast detection and low background. This is also the first time that the distance between the aptamer and antibody binding sites in the membrane protein PTK7 was measured accurately. The SET nanoruler represents the next leap forward to monitor structural components within living cell membranes. PMID:21038856

  5. The morphometric study of l3-L4 and L4-L5 lumbar spine in Asian population using magnetic resonance imaging: feasibility analysis for transpsoas lumbar interbody fusion.

    PubMed

    Yusof, Mohd Imran; Nadarajan, Eswaran; Abdullah, Mohd Shafie

    2014-06-15

    Cross-sectional study on the measurement of relevant magnetic resonance imaging parameters in 100 patients presented for lumbar spine assessment. To determine anatomical position of lumbar plexus and major blood vessels in relation to vertebral body and anterior edge of psoas muscle at L3-L4 and L4-L5 and to define the safe working zone for transpsoas approach for lumbar fusion. Lateral transpsoas lumbar interbody fusion has been shown to be safe and provides alternative for lumbar fusion. However, proximity of neurovascular structures may not allow a safe passage for this procedure in the Asian population. Relevant parameters were measured from axial magnetic resonance images and analyzed, including the psoas muscle and vertebrae endplate diameters, lumbar plexus and psoas muscle distance, lumbar plexus and vertebra body distance, and vena cava to the anterior vertebrae body diameters. The mean anteroposterior diameters of the right and left psoas muscle ranged from 44.0 to 58.6 mm and 44.8 to 54.0 mm, respectively. The mean anteroposterior diameters of vertebra endplate of L3, L4, and L5 were 38.2 mm, 39.3 mm, and 41.4 mm, respectively. The mean distance of posterior border of vena cava from the vertebra body was 4.5 mm at L3-L4 and 14.1 mm at L4-L5. L3-L4 fusion is feasible at both sides in both sexes; however, at L4-L5 level, the procedure is feasible only on the left side. The safe working zone for transpsoas approach to lumbar spine is significantly narrower at L4-L5 in both sexes. Anterior edge of psoas muscle can be used as a reliable guide to locate lumbar plexus within psoas muscle. N/A.

  6. Ultra-compact structure in intermediate-luminosity radio quasars: building a sample of standard cosmological rulers and improving the dark energy constraints up to z 3

    NASA Astrophysics Data System (ADS)

    Cao, Shuo; Zheng, Xiaogang; Biesiada, Marek; Qi, Jingzhao; Chen, Yun; Zhu, Zong-Hong

    2017-09-01

    Context. Ultra-compact structure in radio sources (especially in quasars that can be observed up to very high redshifts), with milliarcsecond angular sizes measured by very-long-baseline interferometry (VLBI), is becoming an important astrophysical tool for probing both cosmology and the physical properties of AGN. Aims: We present a newly compiled data set of 120 milliarcsec. compact radio sources representing intermediate-luminosity quasars covering the redshift range 0.46 < z < 2.76 and check the possibility of using these sources as independent cosmological probes. These quasars observed at 2.29 GHz show negligible dependence on redshifts and intrinsic luminosity, and thus represent a fixed comoving-length of standard ruler. Methods: For a cosmological ruler with intrinsic length lm, the angular size-redshift relation can be written as θ(z) = lm/DA(z, where θ(z) is the angular size at redshift z, and DA(z) is the corresponding angular diameter distance. We use a compilation of angular size and redshift data for ultra-compact radio sources from a well-known VLBI survey, and implement a new cosmology-independent technique to calibrate the linear size of this standard ruler, which is also used to test different cosmological models with and without the flat universe assumption. Results: We determine the linear size of this standard ruler as lm = 11.03 ± 0.25 pc, which is the typical radius at which AGN jets become opaque at the observed frequency ν 2 GHz. Our measurement of this linear size is also consistent with the previous and recent radio observations at other different frequencies. In the framework of flat ΛCDM model, we find a high value of the matter density parameter, Ωm = 0.322+0.244-0.141, and a low value of the Hubble constant, H0 = 67.6+7.8-7.4 km s-1 Mpc-1, which is in excellent agreement with the cosmic microwave background (CMB) anisotropy measurements by Planck. We obtain Ωm = 0.309+0.215-0.151, w = -0.970+0.500-1.730 at 68.3% CL for the constant w of a dynamical dark-energy model, which demonstrates no significant deviation from the concordance ΛCDM model. Consistent fitting results are also obtained for other cosmological models explaining the cosmic acceleration, like Ricci dark energy (RDE) or the Dvali-Gabadadze-Porrati (DGP) brane-world scenario. While no significant change in w with redshift is detected, there is still considerable room for evolution in w and the transition redshift at which w departing from -1 is located at z 2.0. Our results demonstrate that the method extensively investigated in our work on observational radio quasar data can be used to effectively derive cosmological information. Finally, we find the combination of high-redshift quasars and low-redshift clusters may provide an important source of angular diameter distances, considering the redshift coverage of these two astrophysical probes.

  7. PCA as a practical indicator of OPLS-DA model reliability.

    PubMed

    Worley, Bradley; Powers, Robert

    Principal Component Analysis (PCA) and Orthogonal Projections to Latent Structures Discriminant Analysis (OPLS-DA) are powerful statistical modeling tools that provide insights into separations between experimental groups based on high-dimensional spectral measurements from NMR, MS or other analytical instrumentation. However, when used without validation, these tools may lead investigators to statistically unreliable conclusions. This danger is especially real for Partial Least Squares (PLS) and OPLS, which aggressively force separations between experimental groups. As a result, OPLS-DA is often used as an alternative method when PCA fails to expose group separation, but this practice is highly dangerous. Without rigorous validation, OPLS-DA can easily yield statistically unreliable group separation. A Monte Carlo analysis of PCA group separations and OPLS-DA cross-validation metrics was performed on NMR datasets with statistically significant separations in scores-space. A linearly increasing amount of Gaussian noise was added to each data matrix followed by the construction and validation of PCA and OPLS-DA models. With increasing added noise, the PCA scores-space distance between groups rapidly decreased and the OPLS-DA cross-validation statistics simultaneously deteriorated. A decrease in correlation between the estimated loadings (added noise) and the true (original) loadings was also observed. While the validity of the OPLS-DA model diminished with increasing added noise, the group separation in scores-space remained basically unaffected. Supported by the results of Monte Carlo analyses of PCA group separations and OPLS-DA cross-validation metrics, we provide practical guidelines and cross-validatory recommendations for reliable inference from PCA and OPLS-DA models.

  8. Combustion of solid carbon rods in zero and normal gravity

    NASA Technical Reports Server (NTRS)

    Spuckler, C. M.; Kohl, F. J.; Miller, R. A.; Stearns, C. A.; Dewitt, K. J.

    1979-01-01

    In order to investigate the mechanism of carbon combustion, spectroscopic carbon rods were resistance ignited and burned in an oxygen environment in normal and zero gravity. Direct mass spectrometric sampling was used in the normal gravity tests to obtain concentration profiles of CO2, CO, and O2 as a function of distance from the carbon surface. The experimental concentrations were compared to those predicted by a stagnant film model. Zero gravity droptower tests were conducted in order to assess the effect of convection on the normal gravity combustion process. The ratio of flame diameter to rod diameter as a function of time for oxygen pressures of 5, 10, 15, and 20 psia was obtained for three different diameter rods. It was found that this ratio was inversely proportional to both the oxygen pressure and the rod diameter.

  9. Visual acuity from far to near and contrast sensitivity in eyes with a diffractive multifocal intraocular lens with a low addition power.

    PubMed

    Hayashi, Ken; Manabe, Shin-Ichi; Hayashi, Hideyuki

    2009-12-01

    To compare visual acuity from far to near, contrast visual acuity, and acuity in the presence of glare (glare visual acuity) between an aspheric diffractive multifocal intraocular lens (IOL) with a low addition (add) power (+3.0 diopters) and a monofocal IOL. Hayashi Eye Hospital, Fukuoka, Japan. This prospective study comprised patients having implantation of an aspheric diffractive multifocal ReSTOR SN6AD1 IOL with a +3.0 D add (multifocal group) or a monofocal AcrySof IQ SN60WF IOL (monofocal group). Visual acuity from far to near distances, contrast acuity, and glare acuity were evaluated 3 months postoperatively. Each IOL group comprised 64 eyes of 32 patients. For monocular and binocular visual acuity, the mean uncorrected and distance-corrected intermediate acuity at 0.5 m and the near acuity at 0.3 m were significantly better in the multifocal group than in the monofocal group (P

  10. Relationship between spatial and genetic distance in Agrobacterium spp. in 1 cubic centimeter of soil.

    PubMed

    Vogel, J; Normand, P; Thioulouse, J; Nesme, X; Grundmann, G L

    2003-03-01

    The spatial and genetic unit of bacterial population structure is the clone. Surprisingly, very little is known about the spread of a clone (spatial distance between clonally related bacteria) and the relationship between spatial distance and genetic distance, especially at very short scale (microhabitat scale), where cell division takes place. Agrobacterium spp. Biovar 1 was chosen because it is a soil bacterial taxon easy to isolate. A total of 865 microsamples 500 microm in diameter were sampled with spatial coordinates in 1 cm(3) of undisturbed soil. The 55 isolates obtained yielded 42 ribotypes, covering three genomic species based on amplified ribosomal DNA restriction analysis (ARDRA) of the intergenic spacer 16S-23S, seven of which contained two to six isolates. These clonemates (identical ARDRA patterns) could be found in the same microsample or 1 cm apart. The genetic diversity did not change with distance, indicating the same habitat variability across the cube. The mixing of ribotypes, as assessed by the spatial position of clonemates, corresponded to an overlapping of clones. Although the population probably was in a recession stage in the cube (10(3) agrobacteria g(-1)), a high genetic diversity was maintained. In two independent microsamples (500 microm in diameter) at the invasion stage, the average genetic diversity was at the same level as in the cube. Quantification of the microdiversity landscape will help to estimate the probability of encounter between bacteria under realistic natural conditions and to set appropriate sampling strategies for population genetic analysis.

  11. Impact of earliest activation site location in the septal right ventricular outflow tract for identification of left vs right outflow tract origin of idiopathic ventricular arrhythmias.

    PubMed

    Acosta, Juan; Penela, Diego; Herczku, Csaba; Macías, Yolanda; Andreu, David; Fernández-Armenta, Juan; Cipolletta, Laura; Díaz, Andrés; Korshunov, Viatcheslav; Brugada, Josep; Mont, Lluis; Cabrera, Jose A; Sánchez-Quintana, Damián; Berruezo, Antonio

    2015-04-01

    The earliest activation site (EAS) location in the septal right ventricular outflow tract (RVOT) could be an additional mapping data predictor of left ventricular outflow tract (LVOT) vs RVOT origin of idiopathic ventricular arrhythmias (VAs). The purpose of this study was to assess the impact of EAS location in predicting LVOT vs RVOT origin. Macroscopic and histologic study was performed in 12 postmortem hearts. Electroanatomic maps (EAMs) from 37 patients with outflow tract (OT) VA with the EAS in the septal RVOT were analyzed. Pulmonary valve (PV) was defined by voltage scanning after validation of voltage thresholds by image integration. EAM measurements were correlated with those of macroscopic/histologic study. A cutoff value of 1.9 mV discriminated between subvalvular and supravalvular positions (90% sensitivity, 96% specificity). EAS ≥1 cm below PV excluded RVOT site of origin (SOO). According to anatomic findings (distance PV-left coronary cusp = 5 ± 3 vs PV-right coronary cusp = 11 ± 5 mm), EAS-PV distance was significantly shorter in VAs arising from left coronary cusp than from the other LVOT locations (4.2 ± 5.4 mm vs 9.2 ± 7 mm; P = .034). The 10-ms isochronal longitudinal/perpendicular diameter ratio was higher in the RVOT vs the LVOT SOO group (1.97 ± 1.2 vs 0.79 ± 0.49; P = .001). An algorithm based on EAS-PV distance and the 10-ms isochronal longitudinal/perpendicular diameter ratio predicted LVOT SOO with 91% sensitivity and 100% specificity. An algorithm based on the EAS-PV distance and the 10-ms isochronal longitudinal/perpendicular diameter ratio accurately predicts LVOT vs RVOT SOO in outflow tract VAs with EAS in the septal RVOT. Copyright © 2015 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  12. Modeling of dislocation channel width evolution in irradiated metals

    DOE PAGES

    Doyle, Peter J.; Benensky, Kelsa M.; Zinkle, Steven J.

    2017-11-08

    Defect-free dislocation channel formation has been reported to promote plastic instability during tensile testing via localized plastic flow, leading to a distinct loss of ductility and strain hardening in many low-temperature irradiated materials. In order to study the underlying mechanisms governing dislocation channel width and formation, the channel formation process is modeled via a simple stochastic dislocation-jog process dependent upon grain size, defect cluster density, and defect size. Dislocations traverse a field of defect clusters and jog stochastically upon defect interaction, forming channels of low defect-density. And based upon prior molecular dynamics (MD) simulations and in-situ experimental transmission electron microscopymore » (TEM) observations, each dislocation encounter with a dislocation loop or stacking fault tetrahedron (SFT) is assumed to cause complete absorption of the defect cluster, prompting the dislocation to jog up or down by a distance equal to half the defect cluster diameter. Channels are predicted to form rapidly and are comparable to reported TEM measurements for many materials. Predicted channel widths are found to be most strongly dependent on mean defect size and correlated well with a power law dependence on defect diameter and density, and distance from the dislocation source. Due to the dependence of modeled channel width on defect diameter and density, maximum channel width is predicted to slowly increase as accumulated dose increases. The relatively weak predicted dependence of channel formation width with distance, in accordance with a diffusion analogy, implies that after only a few microns from the source, most channels observed via TEM analyses may not appear to vary with distance because of limitations in the field-of-view to a few microns. Furthermore, examinations of the effect of the so-called “source-broadening” mechanism of channel formation showed that its effect is simply to add a minimum thickness to the channel without affecting channel dependence on the given parameters.« less

  13. Modeling of dislocation channel width evolution in irradiated metals

    NASA Astrophysics Data System (ADS)

    Doyle, Peter J.; Benensky, Kelsa M.; Zinkle, Steven J.

    2018-02-01

    Defect-free dislocation channel formation has been reported to promote plastic instability during tensile testing via localized plastic flow, leading to a distinct loss of ductility and strain hardening in many low-temperature irradiated materials. In order to study the underlying mechanisms governing dislocation channel width and formation, the channel formation process is modeled via a simple stochastic dislocation-jog process dependent upon grain size, defect cluster density, and defect size. Dislocations traverse a field of defect clusters and jog stochastically upon defect interaction, forming channels of low defect-density. Based upon prior molecular dynamics (MD) simulations and in-situ experimental transmission electron microscopy (TEM) observations, each dislocation encounter with a dislocation loop or stacking fault tetrahedron (SFT) is assumed to cause complete absorption of the defect cluster, prompting the dislocation to jog up or down by a distance equal to half the defect cluster diameter. Channels are predicted to form rapidly and are comparable to reported TEM measurements for many materials. Predicted channel widths are found to be most strongly dependent on mean defect size and correlated well with a power law dependence on defect diameter and density, and distance from the dislocation source. Due to the dependence of modeled channel width on defect diameter and density, maximum channel width is predicted to slowly increase as accumulated dose increases. The relatively weak predicted dependence of channel formation width with distance, in accordance with a diffusion analogy, implies that after only a few microns from the source, most channels observed via TEM analyses may not appear to vary with distance because of limitations in the field-of-view to a few microns. Further, examinations of the effect of the so-called "source-broadening" mechanism of channel formation showed that its effect is simply to add a minimum thickness to the channel without affecting channel dependence on the given parameters.

  14. Modeling of dislocation channel width evolution in irradiated metals

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Doyle, Peter J.; Benensky, Kelsa M.; Zinkle, Steven J.

    Defect-free dislocation channel formation has been reported to promote plastic instability during tensile testing via localized plastic flow, leading to a distinct loss of ductility and strain hardening in many low-temperature irradiated materials. In order to study the underlying mechanisms governing dislocation channel width and formation, the channel formation process is modeled via a simple stochastic dislocation-jog process dependent upon grain size, defect cluster density, and defect size. Dislocations traverse a field of defect clusters and jog stochastically upon defect interaction, forming channels of low defect-density. And based upon prior molecular dynamics (MD) simulations and in-situ experimental transmission electron microscopymore » (TEM) observations, each dislocation encounter with a dislocation loop or stacking fault tetrahedron (SFT) is assumed to cause complete absorption of the defect cluster, prompting the dislocation to jog up or down by a distance equal to half the defect cluster diameter. Channels are predicted to form rapidly and are comparable to reported TEM measurements for many materials. Predicted channel widths are found to be most strongly dependent on mean defect size and correlated well with a power law dependence on defect diameter and density, and distance from the dislocation source. Due to the dependence of modeled channel width on defect diameter and density, maximum channel width is predicted to slowly increase as accumulated dose increases. The relatively weak predicted dependence of channel formation width with distance, in accordance with a diffusion analogy, implies that after only a few microns from the source, most channels observed via TEM analyses may not appear to vary with distance because of limitations in the field-of-view to a few microns. Furthermore, examinations of the effect of the so-called “source-broadening” mechanism of channel formation showed that its effect is simply to add a minimum thickness to the channel without affecting channel dependence on the given parameters.« less

  15. Improving the effectiveness of (-)-epigallocatechin gallate (EGCG) against rabbit atherosclerosis by EGCG-loaded nanoparticles prepared from chitosan and polyaspartic acid.

    PubMed

    Hong, Zhiyong; Xu, Yongquan; Yin, Jun-Feng; Jin, Jianchang; Jiang, Yongwen; Du, Qizhen

    2014-12-31

    (-)-Epigallocatechin gallate (EGCG) is the major bioactive compound in green tea. Its effect is limited by the harsh environment of the gastrointestinal tract. The present study investigates how the effectiveness of EGCG is influenced by its encapsulation into self-assembled nanoparticles of chitosan (CS) and aspartic acid (PAA). Blank nanoparticles with a mean diameter of ca. 93 nm were prepared from 30-50 kDa PAA and 3-5 kDa CS with a mass rate of 1:1. EGCG was loaded in the nanoparticles to yield EGCG-CS-PAA nanoparticles with an average diameter of 102 nm, which were pH-responsive and demonstrated different EGCG release profiles in simulated gastrointestinal tract media. The average ratio (%) of lipid deposition for EGCG-CS-PAA nanoparticles administered orally to rabbits was 16.9 ± 5.8%, which was close to that of oral simvastatin (15.6 ± 4.1%). Orally administered EGCG alone yielded an average ratio of lipid deposit area of 42.1 ± 4.0%, whereas this value was 65.3 ± 10.8% for the blank nanoparticles. The effectiveness of EGCG against rabbit atherosclerosis was significantly improved by incorporating EGCG into the nanoformulation.

  16. Traffic Data and Its Use in Air Quality Analysis

    EPA Science Inventory

    A study was conducted in Las Vegas, NV from mid-December 2008 to mid-December 2009 to characterize near road emissions and associated ambient concentrations at various distances from a major roadway as a function of meteorology and traffic. The air emissions and meteorological da...

  17. NMR-NOE and MD simulation study on phospholipid membranes: dependence on membrane diameter and multiple time scale dynamics.

    PubMed

    Shintani, Megumi; Yoshida, Ken; Sakuraba, Shun; Nakahara, Masaru; Matubayasi, Nobuyuki

    2011-07-28

    Motional correlation times between the hydrophilic and hydrophobic terminal groups in lipid membranes are studied over a wide range of curvatures using the solution-state (1)H NMR-nuclear Overhauser effect (NOE) and molecular dynamics (MD) simulation. To enable (1)H NMR-NOE measurements for large vesicles, the transient NOE method is combined with the spin-echo method, and is successfully applied to a micelle of 1-palmitoyl-lysophosphatidylcholine (PaLPC) with diameter of 5 nm and to vesicles of dipalmitoylphosphatidylcholine (DPPC) with diameters ranging from 30 to 800 nm. It is found that the NOE intensity increases with the diameter up to ∼100 nm, and the model membrane is considered planar on the molecular level beyond ∼100 nm. While the NOE between the hydrophilic terminal and hydrophobic terminal methyl groups is absent for the micelle, its intensity is comparable to that for the neighboring group for vesicles with larger diameters. The origin of NOE signals between distant sites is analyzed by MD simulations of PaLPC micelles and DPPC planar bilayers. The slow relaxation is shown to yield an observable NOE signal even for the hydrophilic and hydrophobic terminal sites. Since the information on distance and dynamics cannot be separated in the experimental NOE alone, the correlation time in large vesicles is determined by combining the experimental NOE intensity and MD-based distance distribution. For large vesicles, the correlation time is found to vary by 2 orders of magnitude over the proton sites. This study shows that NOE provides dynamic information on large vesicles when combined with MD, which provides structural information. © 2011 American Chemical Society

  18. The Surface Brightness-color Relations Based on Eclipsing Binary Stars: Toward Precision Better than 1% in Angular Diameter Predictions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Graczyk, Dariusz; Gieren, Wolfgang; Konorski, Piotr

    In this study we investigate the calibration of surface brightness–color (SBC) relations based solely on eclipsing binary stars. We selected a sample of 35 detached eclipsing binaries with trigonometric parallaxes from Gaia DR1 or Hipparcos whose absolute dimensions are known with an accuracy better than 3% and that lie within 0.3 kpc from the Sun. For the purpose of this study, we used mostly homogeneous optical and near-infrared photometry based on the Tycho-2 and 2MASS catalogs. We derived geometric angular diameters for all stars in our sample with a precision better than 10%, and for 11 of them with amore » precision better than 2%. The precision of individual angular diameters of the eclipsing binary components is currently limited by the precision of the geometric distances (∼5% on average). However, by using a subsample of systems with the best agreement between their geometric and photometric distances, we derived the precise SBC relations based only on eclipsing binary stars. These relations have precisions that are comparable to the best available SBC relations based on interferometric angular diameters, and they are fully consistent with them. With very precise Gaia parallaxes becoming available in the near future, angular diameters with a precision better than 1% will be abundant. At that point, the main uncertainty in the total error budget of the SBC relations will come from transformations between different photometric systems, disentangling of component magnitudes, and for hot OB stars, the main uncertainty will come from the interstellar extinction determination. We argue that all these issues can be overcome with modern high-quality data and conclude that a precision better than 1% is entirely feasible.« less

  19. Hydrogen adsorption capacities of multi-walled boron nitride nanotubes and nanotube arrays: a grand canonical Monte Carlo study.

    PubMed

    Ahadi, Zohreh; Shadman, Muhammad; Yeganegi, Saeed; Asgari, Farid

    2012-07-01

    Hydrogen adsorption in multi-walled boron nitride nanotubes and their arrays was studied using grand canonical Monte Carlo simulation. The results show that hydrogen storage increases with tube diameter and the distance between the tubes in multi-walled boron nitride nanotube arrays. Also, triple-walled boron nitride nanotubes present the lowest level of hydrogen physisorption, double-walled boron nitride nanotubes adsorb hydrogen better when the diameter of the inner tube diameter is sufficiently large, and single-walled boron nitride nanotubes adsorb hydrogen well when the tube diameter is small enough. Boron nitride nanotube arrays adsorb hydrogen, but the percentage of adsorbed hydrogen (by weight) in boron nitride nanotube arrays is rather similar to that found in multi-walled boron nitride nanotubes. Also, when the Langmuir and Langmuir-Freundlich equations were fitted to the simulated data, it was found that multi-layer adsorptivity occurs more prominently as the number of walls and the tube diameter increase. However, in single-walled boron nitride nanotubes with a small diameter, the dominant mechanism is monolayer adsorptivity.

  20. Controlled transition dipole alignment of energy donor and energy acceptor molecules in doped organic crystals, and the effect on intermolecular Förster energy transfer.

    PubMed

    Wang, Huan; Yue, Bailing; Xie, Zengqi; Gao, Bingrong; Xu, Yuanxiang; Liu, Linlin; Sun, Hongbo; Ma, Yuguang

    2013-03-14

    The orientation factor κ(2) ranging from 0 to 4, which depends on the relative orientation of the transition dipoles of the energy donor (D) and the energy acceptor (A) in space, is one of the pivotal factors deciding the efficiency and directionality of resonance energy transfer (RET) in a D-A molecular system. In this work, tetracene (Tc) and pentacene (Pc) are successfully doped in a trans-1,4-distyrylbenzene (DSB) crystalline lattice to form definite D-A mutually perpendicular transition dipole orientations. The cross D-A dipole arrangement results in an extremely small orientation factor, which is about two orders smaller than that in the disordered films. The energy transfer properties from the host (DSB) to the guest (Tc/Pc) were investigated in detail by steady-state as well as time-resolved fluorescence spectroscopy. Our experimental research results show that the small value of κ(2) allows less or partial energy transfer from the host (DSB) to the guest (Tc) in a wide range of guest concentration, with the Förster distance of around 1.5 nm. By controlling the doping concentrations in the Tc and Pc doubly doped DSB crystals, we demonstrate, as an example, for the first time the application of the restricted energy transfer by D-A cross transition dipole arrangement for preparation of a large-size, white-emissive organic crystal with the CIE coordinates of (0.36, 0.37) approaching an ideal white light. In contrast, Tc is also doped in an anthracene crystalline lattice to form head-to-tail D-A transition dipole alignment, which is proved to be highly effective to promote the intermolecular energy transfer. In this doped system, the orientation factor is relatively large and the Förster distance is around 7 nm.

  1. Studies on shock interactions with moving cylinders using immersed boundary method

    NASA Astrophysics Data System (ADS)

    Luo, Kun; Luo, Yujuan; Jin, Tai; Fan, Jianren

    2017-06-01

    The process of shock interaction with a rigid cylinder is studied using a compressible immersed boundary method combined with a high-order weighted essentially nonoscillatory scheme. Movement of the cylinder is coupled to the flow field. First, the accuracy of the numerical scheme is validated. Then the influences of the incident shock Mach number and the cylinder diameter are discussed. The results are compared with those from cases with stationary cylinders. It is found that variation of either the incident shock Mach number or the cylinder diameter can cause different schlieren images. At a given dimensionless time, the trajectory of the upper triple point varies nonmonotonically with the incident shock Mach number while the primary reflected shock gets closer to the cylinder with increasing incident shock Mach number. For any moving case with a given incident shock Mach number and cylinder diameter, the trajectory of the upper triple point, the time evolution of the normalized vertical distance from the highest point of the primary reflected shock to the centerline of the cylinder, and the time evolution of the normalized shock detachment distance can all be predicted by linear correlation. As for the time evolution of the force exerted on the cylinder, the peak of the moving cylinder appears earlier than the stationary one in dimensionless time, with much lower value. Correlations to predict the occurrence of the peak drag and its value under different shock Mach numbers and cylinder diameters are proposed. The resulting cylinder movement is also briefly discussed.

  2. Nanoprobe diffusion in entangled polymer solutions: Linear vs. unconcatenated ring chains

    NASA Astrophysics Data System (ADS)

    Nahali, Negar; Rosa, Angelo

    2018-05-01

    We employ large-scale molecular dynamics computer simulations to study the problem of nanoprobe diffusion in entangled solutions of linear polymers and unknotted and unconcatenated circular (ring) polymers. By tuning both the diameter of the nanoprobe and the density of the solution, we show that nanoprobes of diameter smaller than the entanglement distance (tube diameter) of the solution display the same (Rouse-like) behavior in solutions of both polymer architectures. Instead, nanoprobes with larger diameters appear to diffuse markedly faster in solutions of rings than in solutions of linear chains. Finally, by analysing the distribution functions of spatial displacements, we find that nanoprobe motion in rings' solutions shows both Gaussian and ergodic behaviors, in all regimes considered, while, in solutions of linear chains, nanoprobes exceeding the size of the tube diameter show a transition to non-Gaussian and non-ergodic motion. Our results emphasize the role of chain architecture in the motion of nanoprobes dispersed in polymer solutions.

  3. Parametric Investigation of Thrust Augmentation by Ejectors on a Pulsed Detonation Tube

    NASA Technical Reports Server (NTRS)

    Wilson, Jack; Sgondea, Alexandru; Paxson, Daniel E.; Rosenthal, Bruce N.

    2006-01-01

    A parametric investigation has been made of thrust augmentation of a 1 in. diameter pulsed detonation tube by ejectors. A set of ejectors was used which permitted variation of the ejector length, diameter, and nose radius, according to a statistical design of experiment scheme. The maximum augmentation ratios for each ejector were fitted using a polynomial response surface, from which the optimum ratios of ejector diameter to detonation tube diameter, and ejector length and nose radius to ejector diameter, were found. Thrust augmentation ratios above a factor of 2 were measured. In these tests, the pulsed detonation device was run on approximately stoichiometric air-hydrogen mixtures, at a frequency of 20 Hz. Later measurements at a frequency of 40 Hz gave lower values of thrust augmentation. Measurements of thrust augmentation as a function of ejector entrance to detonation tube exit distance showed two maxima, one with the ejector entrance upstream, and one downstream, of the detonation tube exit. A thrust augmentation of 2.5 was observed using a tapered ejector.

  4. Dimensionless Numbers For Morphological, Thermal And Biogeochemical Controls Of Hyporheic Processes

    NASA Astrophysics Data System (ADS)

    Bellin, Alberto; Marzadri, Alessandra; Tonina, Daniele

    2013-04-01

    Transport of solutes and heat within the hyporheic zone are interface processes that gained growing attention in the last decade, when several modelling strategies have been proposed, mainly at the local or reach scale. We propose to upscale local hyporheic biogeochemical processes to reach and network scales by means of a Lagrangian modelling framework, which allows to consider the impact of the flow structure on the processes modelled. This analysis shows that geochemical processes can be parametrized through two new Damköhler numbers, DaO, and DaT. DaO = ?up,50-?lim is defined as the ratio between the median hyporheic residence time, ?up,50 and the time of consuming dissolved oxygen to a prescribed threshold concentration, ?lim, below which reductive reactions are activated. It quantifies the biogeochemical status of the hyporheic zone and could be a metric for upscaling local hyporheic biogeochemical processes to reach and river-network scale processes. In addition, ?up,50 is the time scale of hyporheic advection; while ?lim is the representative time scale of biogeochemical reactions and indicates the distance along the streamline, measured as the time needed to travel that distance, that a particle of water travels before the dissolved oxygen concentration declines to [DO]lim, the value at which denitrification is activated. We show that DaO is representative of the redox status and indicates whether the hyporheic zone is a source or a sink of nitrate. Values of DaO larger than 1 indicate prevailing anaerobic conditions, whereas values smaller than 1 prevailing aerobic conditions. Similarly, DaT quantifies the importance of the temperature daily oscillations of the stream water on the hyporheic environment. It is defined as the ratio between ?up,50, and the time limit at which the ratio between the amplitude of the temperature oscillation within the hyporheic zone (evaluated along the streamline) and in the stream water is smaller than e-1. We show that values of DaT > 1 indicate a thermally stable hyporheic zone, where organism metabolism is not influenced by surface water thermal oscillations and biogeochemical reaction rates depend on the mean daily stream water temperature. Values smaller than 1 suggest that organisms need to adapt to the daily thermal variations and biogeochemical reaction rates will depend on the daily fluctuations induced by stream water.

  5. Methanol Droplet Extinction in Carbon-Dioxide-Enriched Environments in Microgravity

    NASA Technical Reports Server (NTRS)

    Hicks, Michael C.; Nayagam, Vedha; Williams, Forman A.

    2010-01-01

    Diffusive extinction of methanol droplets with initial diameters between 1.25 mm and 1.72 mm, burning in a quiescent microgravity environment at one atmosphere pressure, was obtained experimentally for varying levels of ambient carbon-dioxide concentrations with a fixed oxygen concentration of 21% and a balance of nitrogen. These experiments serve as precursors to those which are beginning to be performed on the International Space Station and are motivated by the need to understand the effectiveness of carbon-dioxide as a fire suppressant in low-gravity environments. In these experiments, the flame standoff distance, droplet diameter, and flame radiation are measured as functions of time. The results show that the droplet extinction diameter depends on both the initial droplet diameter and the ambient concentration of carbon dioxide. Increasing the initial droplet diameter leads to an increased extinction diameter, while increasing the carbon-dioxide concentration leads to a slight decrease in the extinction diameter. These results are interpreted using a critical Damk hler number for extinction as predicted by an earlier theory, which is extended here to be applicable in the presence of effects of heat conduction along the droplet support fibers and of the volume occupied by the support beads

  6. Biomechanics of the press-fit phenomenon in dental implantology: an image-based finite element analysis

    PubMed Central

    2012-01-01

    Background A fundamental pre-requisite for the clinical success in dental implant surgery is the fast and stable implant osseointegration. The press-fit phenomenon occurring at implant insertion induces biomechanical effects in the bone tissues, which ensure implant primary stability. In the field of dental surgery, the understanding of the key factors governing the osseointegration process still remains of utmost importance. A thorough analysis of the biomechanics of dental implantology requires a detailed knowledge of bone mechanical properties as well as an accurate definition of the jaw bone geometry. Methods In this work, a CT image-based approach, combined with the Finite Element Method (FEM), has been used to investigate the effect of the drill size on the biomechanics of the dental implant technique. A very accurate model of the human mandible bone segment has been created by processing high resolution micro-CT image data. The press-fit phenomenon has been simulated by FE analyses for different common drill diameters (DA = 2.8 mm, DB = 3.3 mm, and DC = 3.8 mm) with depth L = 12 mm. A virtual implant model has been assumed with a cylindrical geometry having height L = 11 mm and diameter D = 4 mm. Results The maximum stresses calculated for drill diameters DA, DB and DC have been 12.31 GPa, 7.74 GPa and 4.52 GPa, respectively. High strain values have been measured in the cortical area for the models of diameters DA and DB, while a uniform distribution has been observed for the model of diameter DC . The maximum logarithmic strains, calculated in nonlinear analyses, have been ϵ = 2.46, 0.51 and 0.49 for the three models, respectively. Conclusions This study introduces a very powerful, accurate and non-destructive methodology for investigating the effect of the drill size on the biomechanics of the dental implant technique. Further studies could aim at understanding how different drill shapes can determine the optimal press-fit condition with an equally distributed preload on both the cortical and trabecular structure around the implant. PMID:22642768

  7. Cellulase and Xylanase Production from Three Isolates of Indigenous Endophytic Fungi

    NASA Astrophysics Data System (ADS)

    Yopi; Tasia, W.; Melliawati, R.

    2017-12-01

    Cellulases and hemicellulases have good potential to be used in energy production, in pulp, paper, textile industries, as well as in animal feed industries. Moreover, its utilization in food industries also cannot be ignored, among others, cellulase and xylanase roles in bakery, wine, and fruit and vegetables juice production. One of the potential enzyme source is endophytic fungi. Object of this study is to explore the potency of endophytic fungi isolated from medicinal plants as source of cellulolytic and xylanolytic enzymes. HL.47F.216 is endophytic fungi isolated from traditional medicinal plants ironwood tree was determined as xylanase producer. HL.51F.235 from pin-flower tree is cellulase producer, while CBN.6F.29 which produces both xylanase and cellulase is originated from Madagascar periwinkle. HL.47F.216 showed 2.5 cm in clear zone diameter and its xylanase activity was 0.262 U/mL with optimum condition pH 7 at 50°C. HL.51F.235 showed 2.4 cm clear zone diameter and 0.239 U/mL of cellulase activity at pH 5 and 70°C. CBN.6F.29 showed 2.8 cm and 0.394 U/mL (pH 5, 40°C) for its cellulase activity, while 2.3 cm and 0.439 U/mL (pH 8, 70°C) for its xylanase activity. Xylanase from HL.47F.216 and CBN.6F.29 showed low molecular masses of 20 kDa and 37-50 kDa, respectively. Molecular masses for cellulases from HL.51F.235 and CBN.6F.29 were 25 and 50 kDa for HL.51F.235 and 100 kDa for CBN.6F.29. Based on macroscopic and microscopic identification, fungal isolate CBN.6F.29 is a member of Class Coelomycetes, while HL.47F.216 was Acremonium sp. and HL.51F.235 was Aspergillus nigri.

  8. Depletion forces on circular and elliptical obstacles induced by active matter

    NASA Astrophysics Data System (ADS)

    Leite, L. R.; Lucena, D.; Potiguar, F. Q.; Ferreira, W. P.

    2016-12-01

    Depletion forces exerted by self-propelled particles on circular and elliptical passive objects are studied using numerical simulations. We show that a bath of active particles can induce repulsive and attractive forces which are sensitive to the shape and orientation of the passive objects (either horizontal or vertical ellipses). The resultant force on the passive objects due to the active particles is studied as a function of the shape and orientation of the passive objects, magnitude of the angular noise, and distance between the passive objects. By increasing the distance between obstacles the magnitude of the repulsive depletion force increases, as long as such a distance is less than one active particle diameter. For longer distances, the magnitude of the force always decreases with increasing distance. We also found that attractive forces may arise for vertical ellipses at high enough area fraction.

  9. Depletion forces on circular and elliptical obstacles induced by active matter.

    PubMed

    Leite, L R; Lucena, D; Potiguar, F Q; Ferreira, W P

    2016-12-01

    Depletion forces exerted by self-propelled particles on circular and elliptical passive objects are studied using numerical simulations. We show that a bath of active particles can induce repulsive and attractive forces which are sensitive to the shape and orientation of the passive objects (either horizontal or vertical ellipses). The resultant force on the passive objects due to the active particles is studied as a function of the shape and orientation of the passive objects, magnitude of the angular noise, and distance between the passive objects. By increasing the distance between obstacles the magnitude of the repulsive depletion force increases, as long as such a distance is less than one active particle diameter. For longer distances, the magnitude of the force always decreases with increasing distance. We also found that attractive forces may arise for vertical ellipses at high enough area fraction.

  10. One-pot synthesis of magnetite nanorods/graphene composites and its catalytic activity toward electrochemical detection of dopamine.

    PubMed

    Salamon, J; Sathishkumar, Y; Ramachandran, K; Lee, Yang Soo; Yoo, Dong Jin; Kim, Ae Rhan; Gnana Kumar, G

    2015-02-15

    Magnetite (Fe3O4) nanorods anchored over reduced graphene oxide (rGO) were synthesized through a one-pot synthesis method, where the reduction of GO and in-situ generation of Fe3O4 nanorods occurred concurrently. The average head and tail diameter of Fe3O4 nanorods anchored over the rGO matrix are found to be 32 and 11 nm, respectively, and morphology, structure and diameter of bare Fe3O4 nanorods were not altered even after the composite formation with rGO. The increased structural disorders and decrement in the sp(2) domains stimulated the high electrical conductivity and extended catalytic active sites for the prepared rGO/Fe3O4 nanocomposite. The constructed rGO/Fe3O4/GCE sensor exhibited excellent electrocatalytic activity toward the electrooxidation of dopamine (DA) with a quick response time of 6s, a wide linear range between 0.01 and 100.55 µM, high sensitivity of 3.15 µA µM(-1) cm(-2) and a lower detection limit of 7 nM. Furthermore, the fabricated sensor exhibited a practical applicability in the quantification of DA in urine samples with an excellent recovery rate. The excellent electroanalytical performances and straight-forward, surfactant and template free preparation method construct the rGO/Fe3O4 composite as an extremely promising material for the diagnosis of DA related diseases in biomedical applications. Copyright © 2014 Elsevier B.V. All rights reserved.

  11. Designing CBE for Continuing Professional Education.

    ERIC Educational Resources Information Center

    Rees, Keith

    Deakin Australia (DA) CBE (Continuing Business Education) programs are designed for use in conjunction with print and audio materials which are distributed as distance learning packages to business studies graduates working or planning to work as accountants, who are enrolled in the professional licensing program run by the Australian Society of…

  12. Dynamic Assessment, Tutor Mediation and Academic Writing Development

    ERIC Educational Resources Information Center

    Shrestha, Prithvi; Coffin, Caroline

    2012-01-01

    Supporting undergraduate students with their academic literacies has recently been a major focus in higher education in the UK. This paper explores the value of tutor mediation in the context of academic writing development among undergraduate business studies students in open and distance learning, following the dynamic assessment (DA) approach…

  13. Recovery From Experimental Parkinsonism by Semaphorin-guided Axonal Growth of Grafted Dopamine Neurons

    PubMed Central

    Díaz-Martínez, N Emmanuel; Tamariz, Elisa; Díaz, N Fabián; García-Peña, Claudia M; Varela-Echavarría, Alfredo; Velasco, Iván

    2013-01-01

    Cell therapy in animal models of Parkinson's disease (PD) is effective after intrastriatal grafting of dopamine (DA) neurons, whereas intranigral transplantation of dopaminergic cells does not cause consistent behavioral recovery. One strategy to promote axonal growth of dopaminergic neurons from the substantia nigra (SN) to the striatum is degradation of inhibitory components such as chondroitin sulphate proteoglycans (CSPG). An alternative is the guidance of DA axons by chemotropic agents. Semaphorins 3A and 3C enhance axonal growth of embryonic stem (ES) cell–derived dopaminergic neurons in vitro, while Semaphorin 3C also attracts them. We asked whether intranigral transplantation of DA neurons, combined with either degradation of CSPG or with grafts of Semaphorin 3–expressing cells, towards the striatum, is effective in establishing a new nigrostriatal dopaminergic pathway in rats with unilateral depletion of DA neurons. We found depolarization-induced DA release in dorsal striatum, DA axonal projections from SN to striatum, and concomitant behavioral improvement in Semaphorin 3–treated animals. These effects were absent in animals that received intranigral transplants combined with Chondroitinase ABC treatment, although partial degradation of CSPG was observed. These results are evidence that Semaphorin 3–directed long-distance axonal growth of dopaminergic neurons, resulting in behavioral improvement, is possible in adult diseased brains. PMID:23732989

  14. Impact of vent pipe diameter on characteristics of waste degradation in semi-aerobic bioreactor landfill.

    PubMed

    Jiang, Guobin; Liu, Dan; Chen, Weiming; Ye, Zhicheng; Liu, Hong; Li, Qibin

    2017-10-01

    The evolution mechanism of a vent pipe diameter on a waste-stabilization process in semi-aerobic bioreactor landfills was analyzed from the organic-matter concentration, biodegradability, spectral characteristics of dissolved organic matter, correlations and principal-component analysis. Waste samples were collected at different distances from the vent pipe and from different landfill layers in semi-aerobic bioreactor landfills with different vent pipe diameters. An increase in vent pipe diameter favored waste degradation. Waste degradation in landfills can be promoted slightly when the vent pipe diameter increases from 25 to 50 mm. It could be promoted significantly when the vent pipe diameter was increased to 75 mm. The vent pipe diameter is important in waste degradation in the middle layer of landfills. The dissolved organic matter in the waste is composed mainly of long-wave humus (humin), short-wave humus (fulvic acid) and tryptophan. The humification levels of the waste that was located at the center of vent pipes with 25-, 50- and 75-mm diameters were 2.2682, 4.0520 and 7.6419 Raman units, respectively. The appropriate vent pipe diameter for semi-aerobic bioreactor landfills with an 800-mm diameter was 75 mm. The effect of different vent pipe diameters on the degree of waste stabilization is reflected by two main components. Component 1 is related mainly to the content of fulvic acid, biologically degradable material and organic matter. Component 2 is related mainly to the content of tryptophan and humin from the higher vascular plants.

  15. Impact of Distance Determinations on Galactic Structure. I. Young and Intermediate-Age Tracers

    NASA Astrophysics Data System (ADS)

    Matsunaga, Noriyuki; Bono, Giuseppe; Chen, Xiaodian; de Grijs, Richard; Inno, Laura; Nishiyama, Shogo

    2018-06-01

    Here we discuss impacts of distance determinations on the Galactic disk traced by relatively young objects. The Galactic disk, ˜40 kpc in diameter, is a cross-road of studies on the methods of measuring distances, interstellar extinction, evolution of galaxies, and other subjects of interest in astronomy. A proper treatment of interstellar extinction is, for example, crucial for estimating distances to stars in the disk outside the small range of the solar neighborhood. We'll review the current status of relevant studies and discuss some new approaches to the extinction law. When the extinction law is reasonably constrained, distance indicators found in today and future surveys are telling us stellar distribution and more throughout the Galactic disk. Among several useful distance indicators, the focus of this review is Cepheids and open clusters (especially contact binaries in clusters). These tracers are particularly useful for addressing the metallicity gradient of the Galactic disk, an important feature for which comparison between observations and theoretical models can reveal the evolution of the disk.

  16. Gravitational acceleration as a cue for absolute size and distance?

    NASA Technical Reports Server (NTRS)

    Hecht, H.; Kaiser, M. K.; Banks, M. S.

    1996-01-01

    When an object's motion is influenced by gravity, as in the rise and fall of a thrown ball, the vertical component of acceleration is roughly constant at 9.8 m/sec2. In principle, an observer could use this information to estimate the absolute size and distance of the object (Saxberg, 1987a; Watson, Banks, von Hofsten, & Royden, 1992). In five experiments, we examined people's ability to utilize the size and distance information provided by gravitational acceleration. Observers viewed computer simulations of an object rising and falling on a trajectory aligned with the gravitational vector. The simulated objects were balls of different diameters presented across a wide range of simulated distances. Observers were asked to identify the ball that was presented and to estimate its distance. The results showed that observers were much more sensitive to average velocity than to the gravitational acceleration pattern. Likewise, verticality of the motion and visibility of the trajectory's apex had negligible effects on the accuracy of size and distance judgments.

  17. Verification of Emmert's law in actual and virtual environments.

    PubMed

    Nakamizo, Sachio; Imamura, Mariko

    2004-11-01

    We examined Emmert's law by measuring the perceived size of an afterimage and the perceived distance of the surface on which the afterimage was projected in actual and virtual environments. The actual environment consisted of a corridor with ample cues as to distance and depth. The virtual environment was made from the CAVE of a virtual reality system. The afterimage, disc-shaped and one degree in diameter, was produced by flashing with an electric photoflash. The observers were asked to estimate the perceived distance to surfaces located at various physical distances (1 to 24 m) by the magnitude estimation method and to estimate the perceived size of the afterimage projected on the surfaces by a matching method. The results show that the perceived size of the afterimage was directly proportional to the perceived distance in both environments; thus, Emmert's law holds in virtual as well as actual environments. We suggest that Emmert's law is a specific case of a functional principle of distance scaling by the visual system.

  18. Genetic profile based upon 15 microsatellites of four caste groups of the eastern Indian state, Bihar.

    PubMed

    Ashma, R; Kashyap, V K

    2003-01-01

    The formation of caste groups among the Hindu community and the practice of endogamy exert a great impact on the genetic structure and diversity of the Indian population. Allele frequency data of 15 microsatellite loci clearly portray the genetic diversity and relatedness among four socio-culturally advanced caste groups: Brahmin, Bhumihar, Rajput and Kayasth of Caucasoid ethnicity of Bihar. The study seeks to understand the impact of the man-made caste system on the genetic profile of the four major caste groups of Bihar. Computation of average heterozygosity, most frequent allele, allele diversity and coefficient of gene differentiation (Gst), along with genetic distance (DA)and principal coordinate analysis were performed to assess intra-population and inter-population diversity. The average Gst value for all the loci was 0.012 +/- 0.0033, and the level of average heterozygosity was approximately 75.5%, indicating genetic similarity and intra-population diversity. Genetic distance (DA) values and the phylogenetic tree along with other higher caste groups of India indicate the relative distance between them. The present study clearly depicts the genetic profile of these caste groups, their inherent closeness in the past, and the impact of the imposed caste system that later restricted the gene flow. The study highlights the status of Bhumihar and Kayasth in the Hindu caste system. The former was found clustering with the Brahmin group (as expected, since Bhumihar is known to be a subclass of Brahmin), whereas the distance between the Brahmin and Kayasth caste groups was found to be large. North-eastern Indian Mongoloids form a separate cluster.

  19. Random Forest population modelling of striped and common-bottlenose dolphins in the Gulf of Taranto (Northern Ionian Sea, Central-eastern Mediterranean Sea)

    NASA Astrophysics Data System (ADS)

    Carlucci, Roberto; Cipriano, Giulia; Paoli, Chiara; Ricci, Pasquale; Fanizza, Carmelo; Capezzuto, Francesca; Vassallo, Paolo

    2018-05-01

    This study provides the first estimates of density and abundance of the striped dolphin Stenella coeruleoalba and common bottlenose dolphin Tursiops truncatus in the Gulf of Taranto (Northern Ionian Sea, Central Mediterranean Sea) and identifies the predictive variables mainly influencing their occurrence and concentration in the study area. Conventional Distance Sampling (CDS) and the Delta approach on Random Forest (DaRF) methods have been applied to sightings data collected between 2009 and 2016 during standardized vessel-based surveys, providing similar outcomes. The mean value of density over the entire study area was 0.72 ± 0.26 specimens/km2 for the striped dolphin and 0.47 ± 0.09 specimens/km2 for the common bottlenose dolphin. The abundance estimated by DaRF in the Gulf of Taranto was 10080 ± 3584 specimens of S. coeruleoalba and 6580 ± 1270 specimens of T. truncatus, respectively. Eight predictive variables were selected, considering both the local physiographic features and human activities existing in the investigated area. The explanatory variables depth, distance from the coast, distance from industrial areas and distance from areas exploited by fishery seem to play a key role in influencing the spatial distribution of both species, whereas the geomorphological variables proved to be the most significant factors shaping the concentration of both dolphins. The establishment of a Specially Protected Area of Mediterranean Importance (SPAMI) according the SPA/BD Protocol in the Gulf of Taranto is indicated as an effective management tool for the conservation of both dolphin populations in the Central-eastern Mediterranean Sea.

  20. Ion extraction capabilities of closely spaced grids

    NASA Technical Reports Server (NTRS)

    Rovang, D. C.; Wilbur, P. J.

    1982-01-01

    The ion extraction capabilities of accelerator systems with small screen hole diameters (less than 2.0 mm) are investigated at net-accelerating voltages of 100, 300, and 500 V. Results show that the impingement-limited perveance is not dramatically affected by reductions in screen hole diameter to 1.0 mm, but impingement-limited performance was found to be dependent on the grid separation distance, the discharge-to-total accelerating voltage ratio, and the net-to-total accelerating voltage ratio. Results obtained using small hole diameters and closely spaced grids indicate a new mode of grid operation where high current density operation can be achieved with a specified net acceleration voltage by operating the grids at a high rather than low net-to-total acceleration voltage. Beam current densities as high as 25 mA/sq cm were obtained using grids with 1.0 mm diameter holes operating at a net accelerating voltage of 500 V.

  1. Excited argon 1s5 production in micro-hollow cathode discharges for use as potential rare gas laser sources

    NASA Astrophysics Data System (ADS)

    Peterson, Richard D.; Eshel, Ben; Rice, Christopher A.; Perram, Glen P.

    2018-02-01

    The diode-pumped rare gas laser (DPRGL) has been suggested as a potential high-gain, high-energy laser which requires densities on the order of 1013 cm-3 at pressures around 1 atmosphere for efficient operation. Argon 1s5 number densities have been measured in micro-hollow cathode discharges with electrode gaps of 127 and 254 μm and hole diameters from 100-400 μm. The dependency of the metastable argon (1s5) density on total gas pressure, electrode gap distance and hole diameter were explored. The measured densities were all in the range of 0.5 - 2 × 1013 cm-3 with the 400 μm hole diameters being the lowest.

  2. Shock destruction armor system

    DOEpatents

    Froeschner, Kenneth E.

    1993-01-01

    A shock destruction armor system is constructed and arranged to destroy the force of impact of a projectile by shock hydrodynamics. The armor system is designed to comprise a plurality of superimposed armor plates each preferably having a thickness less than five times the projectile's diameter and are preferably separated one-from-another by a distance at least equal to one-half of the projectile's diameter. The armor plates are effective to hydrodynamically and sequentially destroy the projectile. The armor system is particularly adapted for use on various military vehicles, such as tanks, aircraft and ships.

  3. Saturn's moon Tethys

    NASA Technical Reports Server (NTRS)

    1981-01-01

    Voyager 2 obtained this view of Saturn's moon Tethys on Aug.25 from a distance of 540,000 kilometers (335,000 miles). It shows the numerous impact craters and fault valleys of a very ancient surface. Tethys itself is 1,090 km. (675 mi.) in diameter, and the great chasm seen at the top of this image extends 1,700 km. (1,050 mi.), halfway across the satellite. The largest impact crater visible here is 90 km. (55 mi.) in diameter. The Voyager project is managed for NASA by the Jet Propulsion Laboratory, Pasadena, Calif.

  4. Evaluation of white-to-white distance and anterior chamber depth measurements using the IOL Master, slit-lamp adapted optical coherence tomography and digital photographs in phakic eyes.

    PubMed

    Wilczyński, Michał; Pośpiech-Zabierek, Aleksandra

    2015-01-01

    The accurate measurement of the anterior chamber internal diameter and depth is important in ophthalmic diagnosis and before some eye surgery procedures. The purpose of the study was to compare the white-to-white distance measurements performed using the IOL-Master and photography with internal anterior chamber diameter determined using slit lamp adapted optical coherence tomography in healthy eyes, and to compare anterior chamber depth measurements by IOL-Master and slit lamp adapted optical coherence tomography. The data were gathered prospectively from a non-randomized consecutive series of patients. The examined group consisted of 46 eyes of 39 patients. White-to-white was measured using IOL-Master and photographs of the eye were taken with a digital camera. Internal anterior chamber diameter was measured with slit-lamp adapted optical coherence tomography. Anterior chamber depth was measured using the IOL Master and slit-lamp adapted optical coherence tomography. Statistical analysis was performed using parametric tests. A Bland-Altman plot was drawn. White-to-white distance by the IOL Master was 11.8 +/- 0.40 mm, on photographs it was 11.29 +/- 0.58 mm and internal anterior chamber diameter by slit-lamp adapted optical coherence tomography was 11.34?0.54 mm. A significant difference was found between IOL-Master and slit-lamp adapted optical coherence tomography (p<0.01), as well as between IOL Master and digital photographs (p<0.01). There was no difference between SL-OCT and digital photographs (p>0.05). All measurements were correlated (Spearman p<0.001). Mean anterior chamber depth determined using the IOL-Master was 2.99 +/- 0.50 mm and by slit-lamp adapted optical coherence tomography was 2.56 +/- 0.46 mm. The difference was statistically significant (p<0.001). The correlation between the values was also statistically significant (Spearman, p<0.001). Automated measurements using IOL-Master yield constantly higher values than measurements based on direct eye visualization slit-lamp adapted optical coherence tomography and digital photographs. In order to obtain accurate measurements of the internal anterior chamber diameter and anterior chamber depth, a method involving direct visualization of intraocular structures should be used.

  5. Metric Tests for Curvature from Weak Lensing and Baryon Acoustic Oscillations

    NASA Astrophysics Data System (ADS)

    Bernstein, G.

    2006-02-01

    We describe a practical measurement of the curvature of the universe which, unlike current constraints, relies purely on the properties of the Robertson-Walker metric rather than any assumed model for the dynamics and content of the universe. The observable quantity is the cross-correlation between foreground mass and gravitational shear of background galaxies, which depends on the angular diameter distances dA(zl), dA(zs), and dA(zs,zl) on the degenerate triangle formed by observer, source, and lens. In a flat universe, dA(zl,zs)=dA(zs)-dA(zl), but in curved universes an additional term ~Ωk appears and alters the lensing observables even if dA(z) is fixed. We describe a method whereby weak-lensing data can be used to solve simultaneously for dA and the curvature. This method is completely insensitive to the equation of state of the contents of the universe, or amendments to general relativity that alter the gravitational deflection of light or the growth of structure. The curvature estimate is also independent of biases in the photometric redshift scale. This measurement is shown to be subject to a degeneracy among dA, Ωk, and the galaxy bias factors that may be broken by using the same imaging data to measure the angular scale of baryon acoustic oscillations. Simplified estimates of the accuracy attainable by this method indicate that ambitious weak-lensing + baryon-oscillation surveys would measure Ωk to an accuracy ~0.04f-1/2sky(σlnz/0.04)1/2, where σlnz is the photometric redshift error. The Fisher-matrix formalism developed here is also useful for predicting bounds on curvature and other characteristics of parametric dark energy models. We forecast some representative error levels and compare ours to other analyses of the weak-lensing cross-correlation method. We find both curvature and parametric constraints to be surprisingly insensitive to the systematic shear calibration errors.

  6. Permeable disks at low Reynolds numbers

    NASA Astrophysics Data System (ADS)

    Viola, Ignazio Maria; Cummins, Cathal; Mastropaolo, Enrico; Nakayama, Naomi

    2017-11-01

    The wake of a permeable disk can be rather exceptional: a toroidal vortex can form and remains stably at a fixed distance from the disk. The streamwise length of the vortex depends on the Reynolds and Darcy numbers. We investigate this fascinating flow for Reynolds numbers from 10 to 130 and Darcy numbers (Da) from 10-9 to 1. Direct numerical simulations are performed on a 2D grid with axisymmetric boundary conditions. Three flow regimes are observed: for low Da (effectively impervious), the wake is characterized by the presence of a toroidal vortex whose length is approximately equal to that of an impervious disk. For 10-6 < Da <10-3 , the increase in Da causes the vortex to shorten, and eventually vanishes at a critical Darcy number. It is demonstrated that increasing the permeability can lead to large variations in the length of the recirculating wake but with minimal effect on the drag coefficient. For higher Da (highly permeable), there is no recirculation, and an analytical expression for the drag force on the disk is derived, showing good agreement with the numerical results. This work was supported by the Leverhulme Trust [RPG-2015-255].

  7. Construction of a 40-mile long roadside scale model of the solar system in northern Maine

    NASA Astrophysics Data System (ADS)

    McCartney, K.

    2001-05-01

    The Maine Solar System Model is currently under construction along Route 1 between Houlton and Presque Isle, in Aroostook County, northern Maine. The scale is 1:93,000,000, or 1 mile equals an astronomical unit. There is a 40 mile distance between the Sun (diameter 49.5 feet) and Pluto (diameter 1 inch). The model will include the Sun, nine planets and seven moons, with diameters and distances all to the same scale. Except for the Sun, all components will be three-dimensional and built to withstand the northern Maine climate. Construction is generally of steel with fiberglass globes positioned on steel posts at least ten feet above ground and 55 feet off the roadway. Road safety concerns require that the Jupiter and Saturn sites include parking lots. Educational information associated with the model will be provided on brochures, since textual information at the sites would require excessive stops and parking problems. Learning exercises will also be provided by travelling trunks prepared by Maine teachers to support the State of Maine Learning Results. This is a community project with the various components being built by ten area schools and with active assistance from many community members and organizations. It is being built with with very little money, with most materials and labor donated.

  8. Agreement between experimental and theoretical effects of nitrogen gas flowrate on liquid jet atomization

    NASA Technical Reports Server (NTRS)

    Ingebo, Robert D.

    1987-01-01

    Two-phase flows were investigated by using high velocity nitrogen gas streams to atomize small-diameter liquid jets. Tests were conducted primarily in the acceleration-wave regime for liquid jet atomization, where it was found that the loss of droplets due to vaporization had a marked effect on drop size measurements. In addition, four identically designed two-fluid atomizers were fabricated and tested for similarity of spray profiles. A scattered-light scanner was used to measure a characteristic drop diameter, which was correlated with nitrogen gas flowrate. The exponent of 1.33 for nitrogen gas flowrate is identical to that predicted by atomization theory for liquid jet breakup in the acceleration-wave regime. This is higher than the value of 1.2 which was previously obtained at a sampling distance of 4.4 cm downstream of the atomizer. The difference is attributed to the fact that drop-size measurements obtained at a 2.2 cm sampling distance are less effected by vaporization and dispersion of small droplets and therefore should give better agreement with atomization theory. Profiles of characteristic drop diameters were also obtained by making at least five line-of-sight measurements across the spray at several horizontal positions above and below the center line of the spray.

  9. Agreement between experimental and theoretical effects of nitrogen gas flowrate on liquid jet atomization

    NASA Technical Reports Server (NTRS)

    Ingebo, Robert D.

    1987-01-01

    Two-phase flows were investigated by using high velocity nitrogen gas streams to atomize small-diameter liquid jets. Tests were conducted primarily in the acceleration-wave regime for liquid jet atomization, where it was found that the loss of droplets due to vaporization had a marked effect on drop-size measurements. In addition, four identically designed two-fluid atomizers were fabricated and tested for similarity of spray profiles. A scattered-light scanner was used to measure a characteristic drop diameter, which was correlated with nitrogen gas flowrate. The exponent of 1.33 for nitrogen gas flowrate is identical to that predicted by atomization theory for liquid jet breakup in the acceleration-wave regime. This is higher than the value of 1.2 which was previously obtained at a smapling distance of 4.4 cm downstream of the atomizer. The difference is attributed to the fact that drop-size measurements obtained at a 2.2 cm sampling distance are less affected by vaporization and dispersion of small droplets and therefore should give better agreement with atomization theory. Profiles of characteristic drop diameters were also obtained by making at least five line-of-sight measurements across the spray at several horizontal positions above and below the center line of the spray.

  10. Can Coulomb repulsion for charged particle beams be overcome?

    NASA Astrophysics Data System (ADS)

    Retsky, Michael W.

    2004-01-01

    Mutual repulsion of discrete charged particles or Coulomb repulsion is widely considered to be an ultimate hard limit in charged particle optics. It prevents the ability to finely focus high current beams into a small spots at large distances from the defining apertures. A classic example is the 1970s era "Star Wars" study of an electron beam directed energy weapon as an orbiting antiballistic missile device. After much analysis, it was considered physically impossible to focus a 1000-amp 1-GeV beam into a 1-cm diameter spot 1000-km from the beam generator. The main reason was that a 1-cm diameter beam would spread to 5-m diameter at 1000-km due to Coulomb repulsion. Since this could not be overcome, the idea was abandoned. But is this true? What if the rays were reversed? That is, start with a 5-m beam converging slightly with the same nonuniform angular and energy distribution as the electrons from the original problem were spreading at 1000-km distance. Could Coulomb repulsion be overcome? Looking at the terms in computational studies, some are reversible while others are not. Since the nonreversible terms should be small, it might be possible to construct an electron beam directed energy weapon.

  11. Highly sensitive detection of quantal dopamine secretion from pheochromocytoma cells using neural microelectrode array electrodeposited with polypyrrole graphene.

    PubMed

    Wang, Li; Xu, Huiren; Song, Yilin; Luo, Jinping; Wei, Wenjing; Xu, Shengwei; Cai, Xinxia

    2015-04-15

    For the measurement of events of dopamine (DA) release as well as the coordinating neurotransmission in the nerve system, a neural microelectrode array (nMEA) electrodeposited directionally with polypyrrole graphene (PG) nanocomposites was fabricated. The deposited graphene significantly increased the surface area of working electrode, which led to the nMEA (with diameter of 20 μm) with excellent selectivity and sensitivity to DA. Furthermore, PG film modification exhibited low detection limit (4 nM, S/N = 3.21), high sensitivity, and good linearity in the presence of ascorbic acid (e.g., 13933.12 μA mM(-1) cm(-2) in the range of 0.8-10 μM). In particular, the nMEA combined with the patch-clamp system was used to detect quantized DA release from pheochromocytoma cells under 100 mM K(+) stimulation. The nMEA that integrates 60 microelectrodes is novel for detecting a large number of samples simultaneously, which has potential for neural communication research.

  12. A 2D analytical cylindrical gate tunnel FET (CG-TFET) model: impact of shortest tunneling distance

    NASA Astrophysics Data System (ADS)

    Dash, S.; Mishra, G. P.

    2015-09-01

    A 2D analytical tunnel field-effect transistor (FET) potential model with cylindrical gate (CG-TFET) based on the solution of Laplace’s equation is proposed. The band-to-band tunneling (BTBT) current is derived by the help of lateral electric field and the shortest tunneling distance. However, the analysis is extended to obtain the subthreshold swing (SS) and transfer characteristics of the device. The dependency of drain current, SS and transconductance on gate voltage and shortest tunneling distance is discussed. Also, the effect of scaling the gate oxide thickness and the cylindrical body diameter on the electrical parameters of the device is analyzed.

  13. The simultaneous electrochemical detection of ascorbic acid, dopamine, and uric acid using graphene/size-selected Pt nanocomposites.

    PubMed

    Sun, Chia-Liang; Lee, Hsin-Hsien; Yang, Jen-Ming; Wu, Ching-Chou

    2011-04-15

    In this study, a graphene/Pt-modified glassy carbon (GC) electrode was created to simultaneously characterize ascorbic acid (AA), dopamine (DA), and uric acid (UA) levels via cyclic voltammetry (CV) and differential pulse voltammetry (DPV). During the preparation of the nanocomposite, size-selected Pt nanoparticles with a mean diameter of 1.7 nm were self-assembled onto the graphene surface. In the simultaneous detection of the three aforementioned analytes using CV, the electrochemical potential differences among the three detected peaks were 185 mV (AA to DA), 144 mV (DA to UA), and 329 mV (AA and UA), respectively. In comparison to the CV results of bare GC and graphene-modified GC electrodes, the large electrochemical potential difference that is achieved via the use of the graphene/Pt nanocomposites is essential to the distinguishing of these three analytes. An optimized adsorption of size-selected Pt colloidal nanoparticles onto the graphene surface results in a graphene/Pt nanocomposite that can provide a good platform for the routine analysis of AA, DA, and UA. Copyright © 2011 Elsevier B.V. All rights reserved.

  14. Staying away from the optic nerve: a formula for modifying glaucoma drainage device surgery in pediatric and other small eyes.

    PubMed

    Margeta, Milica A; Kuo, Anthony N; Proia, Alan D; Freedman, Sharon F

    2017-02-01

    To provide guidelines for safe implantation of glaucoma drainage devices (GDDs) in small and pediatric eyes to avoid contact between the optic nerve (ON) and the posterior edge of the GDD plate. We developed a formula for calculating limbus-to-ON distance to estimate the available "real estate" for GDD placement in small eyes. The formula was validated using eyes of pediatric decedents undergoing clinical autopsy, with axial lengths (AL) of 15-24 mm. For each autopsy eye, we measured AL, anterior chamber depth, corneal diameter, and limbus-to-ON distances for the four eye quadrants. The main outcome measure was the degree of agreement between measured and calculated limbus-to-ON distances. A total of 15 autopsy eyes were divided into derivation (n = 10) and validation (n = 5) groups. A formula was derived to estimate superotemporal limbus-to-ON distance (D ST ) using AL and corneal diameter data. Linear regression showed excellent correlation between the measured D ST and AL (R 2  = 0.98). There was excellent agreement between measured and calculated limbus-to-ON values for all four eye quadrants (R 2 range, 0.92-0.98). Our formula accurately predicts limbus-to-ON distances across a wide range of clinically relevant ALs. Based on this information, GDD surgery in small eyes can be adjusted by positioning the GDD closer to the limbus or by trimming the posterior edge of the GDD plate. To our knowledge, this is the first set of guidelines developed to promote safe implantation of GDDs in small eyes. Copyright © 2017 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  15. Understanding the tissue interaction of new treatment modalities in laparoscopic surgery in view of safe and effective application (Conference Presentation)

    NASA Astrophysics Data System (ADS)

    Grimbergen, Matthijs C. M.; Klaessens, John H.; van der Veen, Albert J.; Verdaasdonk, Rudolf M.

    2016-03-01

    During laparoscopic surgery, devices are require to either cut, ablate or coagulate tissue and veins with high precision and controlled lateral damage preferably in an one-for-all modality. The tissue interactions of 3 new treatment modalities were studied using special imaging techniques to obtain a better understanding the working mechanism in view of effective and safe application. The Plasmajet produces a high temperature ionized gas 'flame' directed to the tissue surface at the tip of a 4 mm diameter rigid hand piece. The Lumenis DUO CO2 laser enables endoscopic laser energy delivery through a 1 mm outer diameter flexible hollow waveguide. The 2 µm 'Thulium' laser is delivered by (standard) 400 µm diameter optical fiber. Thermal imaging and Schlieren techniques were used to assess the superficial ablative and coagulation effects these surgical instruments scanning at preset velocities and distances from the surface of biological tissues and phantoms . The CO2 was very effective in tissue ablation even at a distance up to 10 mm due to a very small diverging beam from the hollow waveguide. In contrast, the Thulium laser showed less ablation and increasing coagulation at larger distance to the tissue. The gas 'flame' of the Plasmajet spread the thermal energy over the surface for effective superficial ablation and coagulation. However, the pressure of the gas flow is substantial on the tissue surface creating turbulence and even indirect cooling. The specific ablation and coagulation effects of the three treatment modalities have to be appreciate and the effective and safe application will depend on the preference and skills of the surgeon

  16. [Discrimination of donkey meat by NIR and chemometrics].

    PubMed

    Niu, Xiao-Ying; Shao, Li-Min; Dong, Fang; Zhao, Zhi-Lei; Zhu, Yan

    2014-10-01

    Donkey meat samples (n = 167) from different parts of donkey body (neck, costalia, rump, and tendon), beef (n = 47), pork (n = 51) and mutton (n = 32) samples were used to establish near-infrared reflectance spectroscopy (NIR) classification models in the spectra range of 4,000~12,500 cm(-1). The accuracies of classification models constructed by Mahalanobis distances analysis, soft independent modeling of class analogy (SIMCA) and least squares-support vector machine (LS-SVM), respectively combined with pretreatment of Savitzky-Golay smooth (5, 15 and 25 points) and derivative (first and second), multiplicative scatter correction and standard normal variate, were compared. The optimal models for intact samples were obtained by Mahalanobis distances analysis with the first 11 principal components (PCs) from original spectra as inputs and by LS-SVM with the first 6 PCs as inputs, and correctly classified 100% of calibration set and 98. 96% of prediction set. For minced samples of 7 mm diameter the optimal result was attained by LS-SVM with the first 5 PCs from original spectra as inputs, which gained an accuracy of 100% for calibration and 97.53% for prediction. For minced diameter of 5 mm SIMCA model with the first 8 PCs from original spectra as inputs correctly classified 100% of calibration and prediction. And for minced diameter of 3 mm Mahalanobis distances analysis and SIMCA models both achieved 100% accuracy for calibration and prediction respectively with the first 7 and 9 PCs from original spectra as inputs. And in these models, donkey meat samples were all correctly classified with 100% either in calibration or prediction. The results show that it is feasible that NIR with chemometrics methods is used to discriminate donkey meat from the else meat.

  17. Mathematical model in post-mortem estimation of brain edema using morphometric parameters.

    PubMed

    Radojevic, Nemanja; Radnic, Bojana; Vucinic, Jelena; Cukic, Dragana; Lazovic, Ranko; Asanin, Bogdan; Savic, Slobodan

    2017-01-01

    Current autopsy principles for evaluating the existence of brain edema are based on a macroscopic subjective assessment performed by pathologists. The gold standard is a time-consuming histological verification of the presence of the edema. By measuring the diameters of the cranial cavity, as individually determined morphometric parameters, a mathematical model for rapid evaluation of brain edema was created, based on the brain weight measured during the autopsy. A cohort study was performed on 110 subjects, divided into two groups according to the histological presence or absence of (the - deleted from the text) brain edema. In all subjects, the following measures were determined: the volume and the diameters of the cranial cavity (longitudinal and transverse distance and height), the brain volume, and the brain weight. The complex mathematical algorithm revealed a formula for the coefficient ε, which is useful to conclude whether a brain edema is present or not. The average density of non-edematous brain is 0.967 g/ml, while the average density of edematous brain is 1.148 g/ml. The resulting formula for the coefficient ε is (5.79 x longitudinal distance x transverse distance)/brain weight. Coefficient ε can be calculated using measurements of the diameters of the cranial cavity and the brain weight, performed during the autopsy. If the resulting ε is less than 0.9484, it could be stated that there is cerebral edema with a reliability of 98.5%. The method discussed in this paper aims to eliminate the burden of relying on subjective assessments when determining the presence of a brain edema. Copyright © 2016 Elsevier Ltd and Faculty of Forensic and Legal Medicine. All rights reserved.

  18. Oxy-acetylene driven laboratory scale shock tubes for studying blast wave effects

    NASA Astrophysics Data System (ADS)

    Courtney, Amy C.; Andrusiv, Lubov P.; Courtney, Michael W.

    2012-04-01

    This paper describes the development and characterization of modular, oxy-acetylene driven laboratory scale shock tubes. Such tools are needed to produce realistic blast waves in a laboratory setting. The pressure-time profiles measured at 1 MHz using high-speed piezoelectric pressure sensors have relevant durations and show a true shock front and exponential decay characteristic of free-field blast waves. Descriptions are included for shock tube diameters of 27-79 mm. A range of peak pressures from 204 kPa to 1187 kPa (with 0.5-5.6% standard error of the mean) were produced by selection of the driver section diameter and distance from the shock tube opening. The peak pressures varied predictably with distance from the shock tube opening while maintaining both a true blast wave profile and relevant pulse duration for distances up to about one diameter from the shock tube opening. This shock tube design provides a more realistic blast profile than current compression-driven shock tubes, and it does not have a large jet effect. In addition, operation does not require specialized personnel or facilities like most blast-driven shock tubes, which reduces operating costs and effort and permits greater throughput and accessibility. It is expected to be useful in assessing the response of various sensors to shock wave loading; assessing the reflection, transmission, and absorption properties of candidate armor materials; assessing material properties at high rates of loading; assessing the response of biological materials to shock wave exposure; and providing a means to validate numerical models of the interaction of shock waves with structures. All of these activities have been difficult to pursue in a laboratory setting due in part to lack of appropriate means to produce a realistic blast loading profile.

  19. Fire safety distances for open pool fires

    NASA Astrophysics Data System (ADS)

    Sudheer, S.; Kumar, Lokendra; Manjunath, B. S.; Pasi, Amit; Meenakshi, G.; Prabhu, S. V.

    2013-11-01

    Fire accidents that carry huge loss with them have increased in the previous two decades than at any time in the history. Hence, there is a need for understanding the safety distances from different fires with different fuels. Fire safety distances are computed for different open pool fires. Diesel, gasoline and hexane are used as fuels for circular pool diameters of 0.5 m, 0.7 m and 1.0 m. A large square pool fire of 4 m × 4 m is also conducted with diesel as a fuel. All the prescribed distances in this study are purely based on the thermal analysis. IR camera is used to get the thermal images of pool fires and there by the irradiance at different locations is computed. The computed irradiance is presented with the threshold heat flux limits for human beings.

  20. Distanze dei pianeti e dei satelliti nel sistema solare dedotte da massa, raggio equatoriale e densità del corpo centrale.

    NASA Astrophysics Data System (ADS)

    Lupato, G.

    1993-04-01

    The author illustrates an empirical correlation linking planet distances from the Sun to some physical characteristics of the central body such as mass, equatorial radius, density. Such a formula is applicable, with good approximation, also to the major planet satellite systems.

  1. Flare angles measured with ball gage

    NASA Technical Reports Server (NTRS)

    Cleghorn, D.; Wall, W. A.

    1968-01-01

    Precision tungsten carbide balls measure the internal angle of flared joints. Measurements from small and large balls in the flare throat to an external reference point are made. The difference in distances and diameters determine the average slope of the flare between the points of ball contact.

  2. Monte Carlo modelling of large scale NORM sources using MCNP.

    PubMed

    Wallace, J D

    2013-12-01

    The representative Monte Carlo modelling of large scale planar sources (for comparison to external environmental radiation fields) is undertaken using substantial diameter and thin profile planar cylindrical sources. The relative impact of source extent, soil thickness and sky-shine are investigated to guide decisions relating to representative geometries. In addition, the impact of source to detector distance on the nature of the detector response, for a range of source sizes, has been investigated. These investigations, using an MCNP based model, indicate a soil cylinder of greater than 20 m diameter and of no less than 50 cm depth/height, combined with a 20 m deep sky section above the soil cylinder, are needed to representatively model the semi-infinite plane of uniformly distributed NORM sources. Initial investigation of the effect of detector placement indicate that smaller source sizes may be used to achieve a representative response at shorter source to detector distances. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.

  3. Influence of Short Distance Super-large Diameter Shield Tunneling on Existing Tunnels in Sea Areas

    NASA Astrophysics Data System (ADS)

    Li, Zhuolin; Liu, Dagang; Wang, Mingnian; Xiao, Shihui; Yuan, Jiawei

    2018-03-01

    In oder to find out the influence of large diameter shield tunneling on the existing tunnel under the condition of compound strata in the sea area, taking the Maliuzhou traffic tunnel as the research background, numerical simulation and field test were combined to get the regulation of the additional internal force and deformation of the existing tunnel caused by the shield tunneling. Analysis of the data showed that: the shield construction caused the secondary additional internal force; The moment of the vault was most affected by the tunnel excavation; The axial force of the arch bottom was most affected by the excavation of the tunnel. The deformation of arch waist near excavation tunnel was more affected by tunnel excavation than that of the other side. Combined with the construction experience, the influence of the tunnel close-distance construction on the existing tunnel was within the control range, which could ensure the normal construction.

  4. A study of the sink effect by blood vessels in radiofrequency ablation.

    PubMed

    Zorbas, George; Samaras, Theodoros

    2015-02-01

    The objective of the current work was to study the sink effect in radiofrequency ablation (RFA) caused by a blood vessel located close to an electrode in a two-compartment numerical model, consisting of a spherical tumor embedded in healthy liver tissue. Several blood vessels of different sizes were studied at different distances from the electrode. It was found that when a straight blood vessel, cylindrical in shape, is located parallel to the electrode, the minimum distance for a drop of only 10% in the isothermal treatment volume above 50°C, compared to the model without the blood vessel, varies from 4.49 mm (for a vessel of 2mm in diameter) to 20.02 mm (for a vessel 20mm in diameter). The results can be used as a guideline to clinical practitioners, in order to quickly assess the potential impact of existing blood vessels on the resulting treatment volume. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. An Estimation for Availability of Battery less LF Band RFID Tag to Identify Patients in Operation Room from Viewpoint of Engineering

    NASA Astrophysics Data System (ADS)

    Hosaka, Ryosuke

    Nowadays, medical accidents increase in Japanese patient environment. Especially, misidentification of the patients occurred in operation room of higher level hospitals. It is considered that the great deals of accidents are due to mistakes by nurse. However, the accidents are prevented by management of patients. If a suitable patient identification system is developed, the accidents are prevented. In this study, new patient identification system using battery less LF band RFID(Radio Frequency Identification) is proposed. In the method, battery less RFID tag is attached to patient. In operation room, patient is identified before operation using the proposed system. However, identification distance of RFID is small. It is important that extension of the distance. In this study, antennas of RFID tag and sensor are designed. Two types of tag are proposed. One of them is set on wristband. An antenna for the tag is designed as a circular shape with 30mm in diameter. The other one is shaped like a necklace. The antenna is also designed 220mm, 240mm and 260mm in diameter. Using necklace type new antenna, sufficient identification distance for detection of the tag in the operation room is realized. The patient identification is realized using the proposed system

  6. Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency: Twelve-Month Results of the DEFINITIVE AR Study.

    PubMed

    Zeller, Thomas; Langhoff, Ralf; Rocha-Singh, Krishna J; Jaff, Michael R; Blessing, Erwin; Amann-Vesti, Beatrice; Krzanowski, Marek; Peeters, Patrick; Scheinert, Dierk; Torsello, Giovanni; Sixt, Sebastian; Tepe, Gunnar

    2017-09-01

    Studies assessing drug-coated balloons (DCB) for the treatment of femoropopliteal artery disease are encouraging. However, challenging lesions, such as severely calcified, remain difficult to treat with DCB alone. Vessel preparation with directional atherectomy (DA) potentially improves outcomes of DCB. DEFINITIVE AR study (Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency-A Pilot Study of Anti-Restenosis Treatment) was a multicenter randomized trial designed to estimate the effect of DA before DCB to facilitate the development of future end point-driven randomized studies. One hundred two patients with claudication or rest pain were randomly assigned 1:1 to DA+DCB (n=48) or DCB alone (n=54), and 19 additional patients with severely calcified lesions were treated with DA+DCB. Mean lesion length was 11.2±4.0 cm for DA+DCB and 9.7±4.1 cm for DCB ( P =0.05). Predilation rate was 16.7% for DA+DCB versus 74.1% for DCB; postdilation rate was 6.3% for DA+DCB versus 33.3% for DCB. Technical success was superior for DA+DCB (89.6% versus 64.2%; P =0.004). Overall bail-out stenting rate was 3.7%, and rate of flow-limiting dissections was 19% for DCB and 2% for DA+DCB ( P =0.01). One-year primary outcome of angiographic percent diameter stenosis was 33.6±17.7% for DA+DCB versus 36.4±17.6% for DCB ( P =0.48), and clinically driven target lesion revascularization was 7.3% for DA+DCB and 8.0% for DCB ( P =0.90). Duplex ultrasound patency was 84.6% for DA+DCB, 81.3% for DCB ( P =0.78), and 68.8% for calcified lesions. Freedom from major adverse events at 1 year was 89.3% for DA+DCB and 90.0% for DCB ( P =0.86). DA+DCB treatment was effective and safe, but the study was not powered to show significant differences between the 2 methods of revascularization in 1-year follow-up. An adequately powered randomized trial is warranted. http://www.clinicaltrials.gov. Unique Identifier: NCT01366482. Copyright © 2017 The Author(s).

  7. Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency

    PubMed Central

    Langhoff, Ralf; Rocha-Singh, Krishna J.; Jaff, Michael R.; Blessing, Erwin; Amann-Vesti, Beatrice; Krzanowski, Marek; Peeters, Patrick; Scheinert, Dierk; Torsello, Giovanni; Sixt, Sebastian; Tepe, Gunnar

    2017-01-01

    Background— Studies assessing drug-coated balloons (DCB) for the treatment of femoropopliteal artery disease are encouraging. However, challenging lesions, such as severely calcified, remain difficult to treat with DCB alone. Vessel preparation with directional atherectomy (DA) potentially improves outcomes of DCB. Methods and Results— DEFINITIVE AR study (Directional Atherectomy Followed by a Paclitaxel-Coated Balloon to Inhibit Restenosis and Maintain Vessel Patency—A Pilot Study of Anti-Restenosis Treatment) was a multicenter randomized trial designed to estimate the effect of DA before DCB to facilitate the development of future end point-driven randomized studies. One hundred two patients with claudication or rest pain were randomly assigned 1:1 to DA+DCB (n=48) or DCB alone (n=54), and 19 additional patients with severely calcified lesions were treated with DA+DCB. Mean lesion length was 11.2±4.0 cm for DA+DCB and 9.7±4.1 cm for DCB (P=0.05). Predilation rate was 16.7% for DA+DCB versus 74.1% for DCB; postdilation rate was 6.3% for DA+DCB versus 33.3% for DCB. Technical success was superior for DA+DCB (89.6% versus 64.2%; P=0.004). Overall bail-out stenting rate was 3.7%, and rate of flow-limiting dissections was 19% for DCB and 2% for DA+DCB (P=0.01). One-year primary outcome of angiographic percent diameter stenosis was 33.6±17.7% for DA+DCB versus 36.4±17.6% for DCB (P=0.48), and clinically driven target lesion revascularization was 7.3% for DA+DCB and 8.0% for DCB (P=0.90). Duplex ultrasound patency was 84.6% for DA+DCB, 81.3% for DCB (P=0.78), and 68.8% for calcified lesions. Freedom from major adverse events at 1 year was 89.3% for DA+DCB and 90.0% for DCB (P=0.86). Conclusions— DA+DCB treatment was effective and safe, but the study was not powered to show significant differences between the 2 methods of revascularization in 1-year follow-up. An adequately powered randomized trial is warranted. Clinical Trial Registration— http://www.clinicaltrials.gov. Unique Identifier: NCT01366482. PMID:28916599

  8. Low-dose thromboxane A2 receptor stimulation promotes closure of the rat ductus arteriosus with minimal adverse effects.

    PubMed

    Yokota, Tomohiro; Aida, Takashi; Ichikawa, Yasuhiro; Fujita, Takayuki; Yokoyama, Utako; Minamisawa, Susumu

    2012-08-01

    Patent ductus arteriosus (PDA) is a common life-threatening complication among premature infants. Although cyclooxygenase inhibitors are frequently used to treat PDA, as they inhibit the synthesis of prostaglandin E(2), the most potent vasodilator in the ductus arteriosus (DA), their efficacy is often limited. As thromboxane A(2) (TXA(2)) induces vascular contraction via the TXA(2) receptor (TP), we hypothesized that TP stimulation would promote DA closure. To measure the inner diameter of the vessels, a rapid whole-body freezing method was used. Injection of the selective TP agonists U46619 and I-BOP constricted the fetal DA at embryonic day 19 (e19) and e21 in a dose-dependent manner. Of note, U46619 also exerted a vasoconstrictive effect on two different types of postnatal PDA models: premature PDA and hypoxia-induced PDA. We also found that U46619 constricted the ex vivo DA ring to a greater extent than it constricted the ex vivo aorta. Furthermore, we found that U46619 at lower concentrations (up to 0.05 mg/g of body weight) had a minimal vasoconstrictive effect on other vessels and did not induce microthrombosis in the pulmonary capillary arteries. Low-dose TP stimulation constricts the DA with minimal adverse effects at least in rat neonates and our results could point to an alternative potent vasoconstrictor for PDA.

  9. Intranasal Dopamine Reduces In Vivo [(123)I]FP-CIT Binding to Striatal Dopamine Transporter: Correlation with Behavioral Changes and Evidence for Pavlovian Conditioned Dopamine Response.

    PubMed

    de Souza Silva, Maria A; Mattern, Claudia; Decheva, Cvetana; Huston, Joseph P; Sadile, Adolfo G; Beu, Markus; Müller, H-W; Nikolaus, Susanne

    2016-01-01

    Dopamine (DA), which does not cross the blood-brain barrier, has central and behavioral effects when administered via the nasal route. Neither the mechanisms of central action of intranasal dopamine (IN-DA), nor its mechanisms of diffusion and transport into the brain are well understood. We here examined whether IN-DA application influences dopamine transporter (DAT) binding in the dorsal striatum and assessed the extent of binding in relation to motor and exploratory behaviors. We hypothesized that, based on the finding of increased extracellular DA in the striatum induced by application of IN-DA, binding of [(123)I]FP-CIT to the DAT should be decreased due to competition at the receptor. Rats were administered 3 mg/kg IN-DA and vehicle (VEH), with IN-DA injection either preceding or following VEH. Then motor and exploratory behaviors (traveled distance, velocity, center time, sitting, rearing, head-shoulder motility, grooming) were assessed for 30 min in an open field prior to administration of [(123)I]FP-CIT. DAT binding after IN-DA and VEH was measured with small animal SPECT 2 h following administration of the radioligand. (1) After IN-DA application, striatal DAT binding was significantly lower as compared to VEH, indicating that the nasally delivered DA had central action and increased DA levels comparable to that found previously with L-DOPA administration; and (2) DAT binding in response to intranasal VEH was lower when IN-DA application preceded VEH treatment. This finding is suggestive of Pavlovian conditioning of DA at the level of the DAT, since the DA treatment modified (decreased) the binding in response to the subsequent VEH treatment. VEH treatment also reduced motor and exploratory behaviors more when applied before, as compared to when it followed IN-DA application, also indicative of behavioral Pavlovian conditioning akin to that found upon application of various psychostimulant drugs. (a) demonstrate a direct central action of intranasally applied DA on the DAT in the dorsal striatum, indicating enhanced DA availability; and (b) provide first evidence of a Pavlovian conditioned DA response at the DAT. The latter results have relevance to understanding neurochemical mechanisms that underlie placebo action in the treatment of Parkinsonian patients.

  10. [Radiographic study of maxillary sinus associated with molars in adult].

    PubMed

    Hu, Zhi; Sun, Daming; Zhou, Quansheng; Wang, Yuli; Gu, Jingcheng; Han, Yaohua

    2014-12-01

    to explore the relationship between the maxillary sinus volume and the amount of alveolar bone, and the effect of molar loss upon the maxillary sinus was further analyzed,by measuring adult maxillary sinus volume, sinus ridge distance, and calculating the gasification coefficient of maxillary sinus. One hundred and ninety cases (361 maxillary sinus) with CT examinations were collected, they were divided into group A and group B, 121 cases (242 maxillary sinus) of normal subjects served as group A, 42 cases (65 maxillary sinus) with molar part off were B group, in which 31 maxillary sinus with a molar loss were group B1,22 maxillary sinus with two molar loss were B2 group,12 maxillary sinus with three molar loss (one molar remains) were B3 group, 27 cases (54 maxillary sinus) with upper teeth off were C group. Bymeasureing the maxillary sinus volume, sinus ridge distance and the size of the maxillary sinus, calculating the gasification coefficient, we analyzed the relationship between maxillary volume and sinus ridge distance, and comparatively analyzed the differences among the three groups in the size, gasification coefficient, volume of maxillary sinus and sinus ridge distance. In the normal group,the volume of maxillary sinus and sinus ridge distance had a correlation coefficient of -0. 63,(P< 0.05); Sinus ridge distance in group A was larger than the other two groups (P<0.05), and larger in B group than in C group (P<0. 05), anteroposterior maxillary sinus diameter and reft-right diameter in C group was greater than in A group and B group(P<0.05), group C gasification coeffiecent was less than A group and B group (P<0. 05). The volume of maxillary sinus is negatively correlated with the amont of alveolar bone; Upper teeth's shedding promotes maxillary sinus deformation; Maxiuary sinus volume has a tendency to decrease.

  11. Exponentially decaying interaction potential of cavity solitons

    NASA Astrophysics Data System (ADS)

    Anbardan, Shayesteh Rahmani; Rimoldi, Cristina; Kheradmand, Reza; Tissoni, Giovanna; Prati, Franco

    2018-03-01

    We analyze the interaction of two cavity solitons in an optically injected vertical cavity surface emitting laser above threshold. We show that they experience an attractive force even when their distance is much larger than their diameter, and eventually they merge. Since the merging time depends exponentially on the initial distance, we suggest that the attraction could be associated with an exponentially decaying interaction potential, similarly to what is found for hydrophobic materials. We also show that the merging time is simply related to the characteristic times of the laser, photon lifetime, and carrier lifetime.

  12. Laser-Induced Damage to Thin Film Dielectric Coatings.

    DTIC Science & Technology

    1980-10-01

    magnify and reimage the laser spot in the diagnostic Path B. Location [5] (see Figure (9)) is the equi- valent focal plane in Path B to that in Path A at...the thin film sample, (3] . The object distance is between the focal plane and the lens at [6) and the image distance is betv en the lens [6] and the...the equivalent focal plane in the diagnostic path and positioned so that the peak of the beam spatial profile falls on the pinhole. The diameter of the

  13. Cryo-transmission electron tomography of native casein micelles from bovine milk

    PubMed Central

    Trejo, R.; Dokland, T.; Jurat-Fuentes, J.; Harte, F.

    2013-01-01

    Caseins are the principal protein components in milk and an important ingredient in the food industry. In liquid milk, caseins are found as micelles of casein proteins and colloidal calcium nanoclusters. Casein micelles were isolated from raw skim milk by size exclusion chromatography and suspended in milk protein-free serum produced by ultrafiltration (molecular weight cut-off of 3 kDa) of raw skim milk. The micelles were imaged by cryo-electron microscopy and subjected to tomographic reconstruction methods to visualize the 3-dimensional and internal organization of native casein micelles. This provided new insights into the internal architecture of the casein micelle that had not been apparent from prior cryo-transmission electron microscopy studies. This analysis demonstrated the presence of water-filled cavities (~20 to 30 nm in diameter), channels (diameter greater than ~5 nm), and several hundred high-density nanoclusters (6 to 12 nm in diameter) within the interior of the micelles. No spherical protein submicellar structures were observed. PMID:22118067

  14. Observational calibration of the projection factor of Cepheids. I. The type II Cepheid κ Pavonis

    NASA Astrophysics Data System (ADS)

    Breitfelder, J.; Kervella, P.; Mérand, A.; Gallenne, A.; Szabados, L.; Anderson, R. I.; Willson, M.; Le Bouquin, J.-B.

    2015-04-01

    Context. The distance of pulsating stars, in particular Cepheids, are commonly measured using the parallax of pulsation technique. The different versions of this technique combine measurements of the linear diameter variation (from spectroscopy) and the angular diameter variation (from photometry or interferometry) amplitudes, to retrieve the distance in a quasi-geometrical way. However, the linear diameter amplitude is directly proportional to the projection factor (hereafter p-factor), which is used to convert spectroscopic radial velocities (i.e., disk integrated) into pulsating (i.e., photospheric) velocities. The value of the p-factor and its possible dependence on the pulsation period are still widely debated. Aims: Our goal is to measure an observational value of the p-factor of the type-II Cepheid κ Pavonis. Methods: The parallax of the type-II Cepheid κ Pav was measured with an accuracy of 5% using HST/FGS. We used this parallax as a starting point to derive the p-factor of κ Pav, using the SPIPS technique (Spectro-Photo-Interferometry of Pulsating Stars), which is a robust version of the parallax-of-pulsation method that employs radial velocity, interferometric and photometric data. We applied this technique to a combination of new VLTI/PIONIER optical interferometric angular diameters, new CORALIE and HARPS radial velocities, as well as multi-colour photometry and radial velocities from the literature. Results: We obtain a value of p = 1.26 ± 0.07 for the p-factor of κ Pav. This result agrees with several of the recently derived Period-p-factor relationships from the literature, as well as previous observational determinations for Cepheids. Conclusions: Individual estimates of the p-factor are fundamental to calibrating the parallax of pulsation distances of Cepheids. Together with previous observational estimates, the projection factor we obtain points to a weak dependence of the p-factor on period. Based on observations realized with ESO facilities at Paranal Observatory under program IDs 091.D-0020 and 093.D-0316.Based on observations collected at ESO La Silla Observatory using the Coralie spectrograph mounted to the Swiss 1.2 m Euler telescope, under program CNTAC2014A-5.

  15. Hindlimb heating increases vascular access of large molecules to murine tibial growth plates measured by in vivo multiphoton imaging

    PubMed Central

    Efaw, Morgan L.; Williams, Rebecca M.

    2013-01-01

    Advances in understanding the molecular regulation of longitudinal growth have led to development of novel drug therapies for growth plate disorders. Despite progress, a major unmet challenge is delivering therapeutic agents to avascular-cartilage plates. Dense extracellular matrix and lack of penetrating blood vessels create a semipermeable “barrier,” which hinders molecular transport at the vascular-cartilage interface. To overcome this obstacle, we used a hindlimb heating model to manipulate bone circulation in 5-wk-old female mice (n = 22). Temperatures represented a physiological range of normal human knee joints. We used in vivo multiphoton microscopy to quantify temperature-enhanced delivery of large molecules into tibial growth plates. We tested the hypothesis that increasing hindlimb temperature from 22°C to 34°C increases vascular access of large systemic molecules, modeled using 10, 40, and 70 kDa dextrans that approximate sizes of physiological regulators. Vascular access was quantified by vessel diameter, velocity, and dextran leakage from subperichondrial plexus vessels and accumulation in growth plate cartilage. Growth plate entry of 10 kDa dextrans increased >150% at 34°C. Entry of 40 and 70 kDa dextrans increased <50%, suggesting a size-dependent temperature enhancement. Total dextran levels in the plexus increased at 34°C, but relative leakage out of vessels was not temperature dependent. Blood velocity and vessel diameter increased 118% and 31%, respectively, at 34°C. These results demonstrate that heat enhances vascular carrying capacity and bioavailability of large molecules around growth plates, suggesting that temperature could be a noninvasive strategy for modulating delivery of therapeutics to impaired growth plates of children. PMID:24371019

  16. Control of optical bandgap energy and optical absorption coefficient by geometric parameters in sub-10 nm silicon-nanodisc array structure

    NASA Astrophysics Data System (ADS)

    Fairuz Budiman, Mohd; Hu, Weiguo; Igarashi, Makoto; Tsukamoto, Rikako; Isoda, Taiga; Itoh, Kohei M.; Yamashita, Ichiro; Murayama, Akihiro; Okada, Yoshitaka; Samukawa, Seiji

    2012-02-01

    A sub-10 nm, high-density, periodic silicon-nanodisc (Si-ND) array has been fabricated using a new top-down process, which involves a 2D array bio-template etching mask made of Listeria-Dps with a 4.5 nm diameter iron oxide core and damage-free neutral-beam etching (Si-ND diameter: 6.4 nm). An Si-ND array with an SiO2 matrix demonstrated more controllable optical bandgap energy due to the fine tunability of the Si-ND thickness and diameter. Unlike the case of shrinking Si-ND thickness, the case of shrinking Si-ND diameter simultaneously increased the optical absorption coefficient and the optical bandgap energy. The optical absorption coefficient became higher due to the decrease in the center-to-center distance of NDs to enhance wavefunction coupling. This means that our 6 nm diameter Si-ND structure can satisfy the strict requirements of optical bandgap energy control and high absorption coefficient for achieving realistic Si quantum dot solar cells.

  17. Error analysis and corrections to pupil diameter measurements with Langley Research Center's oculometer

    NASA Technical Reports Server (NTRS)

    Fulton, C. L.; Harris, R. L., Jr.

    1980-01-01

    Factors that can affect oculometer measurements of pupil diameter are: horizontal (azimuth) and vertical (elevation) viewing angle of the pilot; refraction of the eye and cornea; changes in distance of eye to camera; illumination intensity of light on the eye; and counting sensitivity of scan lines used to measure diameter, and output voltage. To estimate the accuracy of the measurements, an artificial eye was designed and a series of runs performed with the oculometer system. When refraction effects are included, results show that pupil diameter is a parabolic function of the azimuth angle similar to the cosine function predicted by theory: this error can be accounted for by using a correction equation, reducing the error from 6% to 1.5% of the actual diameter. Elevation angle and illumination effects were found to be negligible. The effects of counting sensitivity and output voltage can be calculated directly from system documentation. The overall accuracy of the unmodified system is about 6%. After correcting for the azimuth angle errors, the overall accuracy is approximately 2%.

  18. Experimental wake survey behind a 140 deg-included-angle cone at angles of attack of 0 deg and 5 deg, Mach numbers from 1.60 to 3.95, and longitudinal stations varying from 1.0 to 8.39 body diameters

    NASA Technical Reports Server (NTRS)

    Brown, C. A., Jr.; Campbell, J. F.

    1971-01-01

    The flow properties in the wake of a 140 deg-included-angle cone at Mach numbers from 1.60 to 3.95 and at angles of attack of 0 deg and 5 deg are discussed. The wake flow properties are calculated from total and static pressures measured with a pressure rake at longitudinal stations varying from 1.0 to 8.39 body diameters and at lateral stations varying from -0.42 to 3.0 body diameters. These measurements show a consistent trend throughout the range of Mach number and longitudinal distance and an increase in dynamic pressure with increasing longitudinal station.

  19. Experimental wake survey behind Viking 1975 entry vehicle at angles of attack of 0 deg and 5 deg, Mach numbers from 1.60 to 3.95, and longitudinal stations from 1.0 to 8.39 body diameters

    NASA Technical Reports Server (NTRS)

    Brown, C. A., Jr.; Campbell, J. F.; Tudor, D. H.

    1971-01-01

    An investigation was conducted to obtain flow properties in the wake of the Viking '75 entry vehicle at Mach numbers from 1.60 to 3.95 and at angles of attack of 0 deg and 5 deg. The wake flow properties were calculated from total and static pressures measured with a pressure rake at longitudinal stations varying from 1.0 to 8.39 body diameters and lateral stations varying from -0.42 to 3.0 body diameters. These measurements showed a a consistent trend throughout the range of Mach numbers and longitudinal distances and an increase in dynamic pressure with increasing downstream position.

  20. The Distance to the Massive Galactic Cluster Westerlund 2 from a Spectroscopic and HST Photometric Study

    NASA Astrophysics Data System (ADS)

    Vargas Álvarez, Carlos A.; Kobulnicky, Henry A.; Bradley, David R.; Kannappan, Sheila J.; Norris, Mark A.; Cool, Richard J.; Miller, Brendan P.

    2013-05-01

    We present a spectroscopic and photometric determination of the distance to the young Galactic open cluster Westerlund 2 using WFPC2 imaging from the Hubble Space Telescope (HST) and ground-based optical spectroscopy. HST imaging in the F336W, F439W, F555W, and F814W filters resolved many sources previously undetected in ground-based observations and yielded photometry for 1136 stars. We identified 15 new O-type stars, along with two probable binary systems, including MSP 188 (O3 + O5.5). We fit reddened spectral energy distributions based on the Padova isochrones to the photometric data to determine individual reddening parameters RV and AV for O-type stars in Wd2. We find average values langRV rang = 3.77 ± 0.09 and langAV rang = 6.51 ± 0.38 mag, which result in a smaller distance than most other spectroscopic and photometric studies. After a statistical distance correction accounting for close unresolved binaries (factor of 1.08), our spectroscopic and photometric data on 29 O-type stars yield that Westerlund 2 has a distance langdrang = 4.16 ± 0.07 (random) +0.26 (systematic) kpc. The cluster's age remains poorly constrained, with an upper limit of 3 Myr. Finally, we report evidence of a faint mid-IR polycyclic aromatic hydrocarbon ring surrounding the well-known binary candidate MSP 18, which appears to lie at the center of a secondary stellar grouping within Westerlund 2. Based on observations obtained at the Southern Astrophysical Research (SOAR) telescope, which is a joint project of the Ministério da Ciência, Tecnologia, e Inovação (MCTI) da República Federativa do Brasil, the U.S. National Optical Astronomy Observatory (NOAO), the University of North Carolina at Chapel Hill (UNC), and Michigan State University (MSU).

  1. HUBBLE: ON THE ASTEROID TRAIL

    NASA Technical Reports Server (NTRS)

    2002-01-01

    Astronomers Karl Stapelfeldt and Robin Evans have tracked down about 100 small asteroids by hunting through more than 28,000 archival images taken by the Hubble Space Telescope's Wide Field and Planetary Camera 2. Here is a sample of what they have found: four archival images that show the curved trails left by asteroids. [Top left]: Hubble captured a bright asteroid, with a visual magnitude of 18.7, roaming in the constellation Centaurus. Background stars are shown in white, while the asteroid trail is depicted in blue at top center. The trail has a length of 19 arc seconds. This asteroid has a diameter of one and one-quarter miles (2 kilometers), and was located 87 million miles from Earth and 156 million miles from the sun. Numerous orange and blue specks in this image and the following two images were created by cosmic rays, energetic subatomic particles that struck the camera's detector. [Top right]: Here is an asteroid with a visual magnitude of 21.8 passing a galaxy in the constellation Leo. The trail is seen in two consecutive exposures, the first shown in blue and the second in red. This asteroid has a diameter of half a mile (0.8 kilometers), and was located 188 million miles from Earth and 233 million miles from the sun. [Lower left]: This asteroid in the constellation Taurus has a visual magnitude of 23, and is one of the faintest seen so far in the Hubble archive. It moves from upper right to lower left in two consecutive exposures; the first trail is shown in blue and the second in red. Because of the asteroid's relatively straight trail, astronomers could not accurately determine its distance. The estimated diameter is half a mile (0.8 kilometers) at an Earth distance of 205 million miles and a sun distance of 298 million miles. [Lower right]: This is a broken asteroid trail crossing the outer regions of galaxy NGC 4548 in Coma Berenices. Five trail segments (shown in white) were extracted from individual exposures and added to a cleaned color image of the galaxy. The asteroid enters the image at top center and moves down toward the lower left. Large gaps in the trail occur because the telescope is orbiting the Earth and cannot continuously observe the galaxy. This asteroid has a visual magnitude of 20.8, a diameter of one mile (1.6 kilometers), and was seen at a distance of 254 million miles from Earth and 292 million miles from the sun. Credit: R. Evans and K. Stapelfeldt (Jet Propulsion Laboratory) and NASA

  2. Quantification and statistical significance analysis of group separation in NMR-based metabonomics studies

    PubMed Central

    Goodpaster, Aaron M.; Kennedy, Michael A.

    2015-01-01

    Currently, no standard metrics are used to quantify cluster separation in PCA or PLS-DA scores plots for metabonomics studies or to determine if cluster separation is statistically significant. Lack of such measures makes it virtually impossible to compare independent or inter-laboratory studies and can lead to confusion in the metabonomics literature when authors putatively identify metabolites distinguishing classes of samples based on visual and qualitative inspection of scores plots that exhibit marginal separation. While previous papers have addressed quantification of cluster separation in PCA scores plots, none have advocated routine use of a quantitative measure of separation that is supported by a standard and rigorous assessment of whether or not the cluster separation is statistically significant. Here quantification and statistical significance of separation of group centroids in PCA and PLS-DA scores plots are considered. The Mahalanobis distance is used to quantify the distance between group centroids, and the two-sample Hotelling's T2 test is computed for the data, related to an F-statistic, and then an F-test is applied to determine if the cluster separation is statistically significant. We demonstrate the value of this approach using four datasets containing various degrees of separation, ranging from groups that had no apparent visual cluster separation to groups that had no visual cluster overlap. Widespread adoption of such concrete metrics to quantify and evaluate the statistical significance of PCA and PLS-DA cluster separation would help standardize reporting of metabonomics data. PMID:26246647

  3. Fabrication, characterization, and potential application of carbon fiber cone nanometer-size electrodes.

    PubMed

    Zhang, X; Zhang, W; Zhou, X; Ogorevc, B

    1996-10-01

    A novel method has been developed for the fabrication of carbon fiber cone nanometer-size ultramicroelectrodes (nanoelectrodes) with overall tip dimensions as small as 50 nm in diameter. In this method, carbon fibers were initially etched by an argon ion beam thinner. Afterward, a single etched carbon fiber was inserted into a glass capillary, which was then sealed by heating the glass/fiber interface in a vacuum; thus, no epoxy resin is involved. The success rate of our fabrication route for the electrodes with overall tip diameters of up to 500 nm was about 80%; for those with tip diameters of up to 100 nm, it was about 50%. The fabricated carbon fiber cone nanoelectrodes (CFCNEs) were inspected by optical and scanning electron microscopy. Their electrochemical behavior was examined by cyclic and linear sweep voltammetric measurements of ferricyanide and ferrocene ions in aqueous and nonaqueous media. The potential analytical applicability of the CFCNEs was tested by differential pulse voltammetric measurements of two well-known neurotransmitters, dopamine (DA) and 5-hydroxytryptamine (5-HT), and the results achieved were highly satisfactory. The calibration plots obtained were linear over the ranges from 5.0 × 10(-7) to 1.0 × 10(-4) and from 2.0 × 10(-6) to 1.0 × 10(-4) mol/L, with limits of detection of 1.0 × 10(-7) and 5.0 × 10(-7) mol/L for DA and 5-HT, respectively. Some advantages and improvements of the proposed CFCNE fabrication method, especially with respect to smoothness of the fiber (electrode) surface, strength, and control over the fiber tip dimensions, are also discussed.

  4. The Dependence of the Ultrasound-Induced Blood-Brain Barrier Opening Characteristics on Microbubble Size In Vivo

    NASA Astrophysics Data System (ADS)

    Choi, James J.; Feshitan, Jameel A.; Wang, Shougang; Tung, Yao-Sheng; Baseri, Babak; Borden, Mark A.; Konofagou, Elisa E.

    2009-04-01

    Recent neuropharmaceutical developments have led to potent disease-modifying drugs. In spite of these advancements, most agents cannot traverse the blood-brain barrier (BBB) and deposit in the brain. Focused ultrasound (FUS) with microbubbles has been shown to induce noninvasive, localized, and transient BBB opening. Although promising, safety and efficacy concerns still remain. Previously reported experiments used conventional imaging contrast agents that have a wide size distribution. In this study, we hypothesize that BBB opening characteristics are dependent on bubble diameter. A 25 μl bolus of in-house manufactured, lipid-shelled bubbles with either 1-2 or 4-5 μm diameter ranges was injected intravenously. Pulsed FUS (frequency: 1.5 MHz, peak-negative pressure: 146-607 kPa, duty cycle: 20%, duration: 1-min) was then applied to the left hippocampus of mice (n = 16) in vivo through the intact skin and skull. MRI or fluorescence microscopy was used to determine BBB opening. Contrast-enhanced (Omniscan™; 0.75 mL; molecular weight: 574 Da) MRI (9.4-T) was acquired on multiple days after sonication to determine BBB opening and closing. Fluorescence microscopy was also used to determine the feasibility of delivering large, 3 kDa dextran compounds through the BBB. The BBB opening acoustic pressure threshold for the 4-5μm bubbles was in the 146-304 kPa range while the threshold for the 1-2μm bubbles was higher. In conclusion, FUS-induced BBB opening and closing was shown to be dependent on the bubble diameter indicating the possibility of specifically designing bubbles to enhance this therapeutic application.

  5. Exposure of a liquefied gas container to an external fire.

    PubMed

    Raj, Phani K

    2005-06-30

    In liquefied gas, bulk-storage facilities and plants, the separation distances between storage tanks and between a tank and a line of adjoining property that can be built are governed by local regulations and/or codes (e.g. National Fire Protection Association (NFPA) 58, 2004). Separation distance requirements have been in the NFPA 58 Code for over 60 years; however, no scientific foundations (either theoretical or experimental) are available for the specified distances. Even though the liquefied petroleum gas (LPG) industry has operated safely over the years, there is a question as to whether the code-specified distances provide sufficient safety to LPG-storage tanks, when they are exposed to large external fires. A radiation heat-transfer-based model is presented in this paper. The temporal variation of the vapor-wetted tank-wall temperature is calculated when exposed to thermal radiation from an external, non-impinging, large, 30.5 m (100 ft) diameter, highly radiative, hydrocarbon fuel (pool) fire located at a specified distance. Structural steel wall of a pressurized, liquefied gas container (such as the ASME LP-Gas tank) begins to lose its strength, when the wall temperature approaches a critical temperature, 810 K (1000 degrees F). LP-Gas tank walls reaching close to this temperature will be a cause for major concern because of increased potential for tank failure, which could result in catastrophic consequences. Results from the model for exposure of different size ASME (LP-Gas) containers to a hydrocarbon pool fire of 30.5 m (100 ft) in diameter, located with its base edge at the separation distances specified by NFPA 58 [NFPA 58, Liquefied Petroleum Gas Code, Table 6.3.1, 2004 ed., National Fire Protection Association, Quincy, MA, 2004] indicate that the vapor-wetted wall temperature of the containers never reach the critical temperature under common wind conditions (0, 5 and 10 m/s), with the flame tilting towards the tank. This indicates that the separation distances specified in the code are adequate for non-impingement type of fires. The model can be used to test the efficacy of other similar codes and regulations for other materials.

  6. Goldstone radar imaging of near-Earth asteroids (469896) 2007 WV4, 2014 JO25, 2017 BQ6, and 2017 CS

    NASA Astrophysics Data System (ADS)

    Naidu, S.; Benner, L.; Brozovic, M.; Giorgini, J. D.; Busch, M.; Jao, J. S.; Lee, C. G.; Snedeker, L. G.; Silva, M. A.; Slade, M. A.; Lawrence, K. J.

    2017-12-01

    We present Goldstone radar imaging of four near-Earth asteroids during Feb-Jun 2017. The signal-to-noise ratios were very strong for each object and we obtained detailed images with range resolutions as fine as 3.75 m/pixel. 2017 BQ6 was discovered on Jan 26 and approached Earth within 6.5 lunar distances on Feb 7. Radar images show that it is a strikingly angular object roughly 200 m in diameter with a rotation period of 3 h. Its multi-faceted shape challenges the expectation that it is a rubble pile. 2017 CS was discovered on Feb 2 and approached within 8 lunar distances on May 29. It appears rounded on large scales but has considerable fine-scale topography evident along its leading edges. The images suggest a diameter of 1 km and a spin period consistent with the 40 h period obtained from photometry by P. Pravec (pers. comm.). The highest resolution images show evidence for meter-size boulders, ridges, and broad concavities. 2007 WV4 was imaged in late May and early June, has a diameter of 900 meters, and appears distinctly angular with at least three large facets > 100 m in extent. Tracking of features in the images gives a rotation period of about 12 hours. 2014 JO25 approached within 4.6 lunar distances on April 19. This was the closest encounter by an asteroid with an absolute magnitude brighter than 18 known in advance until 2027, when 1999 AN10 will approach within one lunar distance. Radar imaging shows that 2014 JO25 is an irregular object, consisting of two components connected by a narrow neck. The asteroid has pole on dimensions of roughly 1 x 0.6 km in the images. Imaging with 3.75 m/pixel resolution places thousands of pixels on the object and reveals ridges, concavities, flat regions up to 200 meters long, and radar-bright spots suggestive of boulders. Tracking of features in the images yields a rotation period of about 4.5 hours that is among the fastest of the 50 known contact binaries in the near-Earth population.

  7. Dark zone in the centre of the Arago-Poisson diffraction spot of a helical laser beam

    NASA Astrophysics Data System (ADS)

    Emile, O.; Voisin, A.; Niemiec, R.; Viaris de Lesegno, B.; Pruvost, L.; Ropars, G.; Emile, J.; Brousseau, C.

    2013-03-01

    We report on the diffraction of non-zero Laguerre Gaussian laser beams by an opaque disk. We observe a tiny circular dark zone at the centre of the usual Arago-Poisson diffraction bright spot. For such non-diffracting dark hollow beams, we have measured diameters as small as 20 μm on distances of the order of ten metres, without focalization. Diameters depend on the diffracting object size and on the topological charge of the input Laguerre Gaussian beam. These results are in good agreement with theoretical considerations. Potential applications are then discussed.

  8. OPERATION SUNBEAM, SHOT SMALL BOY. Project Officer’s Report. Project 2.9. Fallout Collection and Gross Sample Analysis

    DTIC Science & Technology

    1985-09-01

    concepts for large scale radiological defense operations. 2. 212 CP 2 PR0c J 2.1 PLAJWU This project participated in the single shotp A Boy, fired on a...inch diameter by 3 inch high NaI scintilla- tion counter taking sample tubes up to 1-1/4 inches in diameter. -The crystal was mounted on an W type...inch high Nal scin- tillation counter. The crystal -source distance was 8-3/4 inches. Shielding consisted of a lead cylinder 2 inches thick, 7 inches

  9. SUMMARY OF PROGRESS ON THE STUDY OF BETA TREATMENT OF URANIUM, NOVEMBER 1, 1959-AUGUST 31, 1960

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Russell, R.B.

    Variables affecting the texture and grain size of uranium during beta treatment are summarized. The study of the effect of time and temperature in the beta phase on the growth index (G3) and grain size of the final alpha product is tentatively believed to show that higher beta temperatures for short times (up to about seven minutes) tend to promote slightly more negative growth indices and that higher beta temperatures give rise to somewhat finer grain sizes. Results of studies of both Jominy end-quenched bars and several full-sized rods and tubes quenched by total immersion showed that large thermal gradientsmore » promoted negative growth indices and produced grains somewhat elongated in the direction of the thermal gradient. The effects of endcooling in full-sized pieces quenched by total immersion in cold water showed that the axial growth index is negative up to distances from the end of about half the wall thickness of tubes and about half the radial dimension of rods. The grain refinement penetrates to a lesser distance from the ends. In the radial direction the growth index for these same pieces is largely negative to a distance below the outer diameter of about midwall in two tubes studied. In the case of one tube which was studied more completely, the growth index became negative again as the inner diameter was approached. A water-quenched rod was found to have a negative growth index down to a distance from the surface of about midradius. (auth)« less

  10. 21 CFR 888.4150 - Calipers for clinical use.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ....4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... or diameter of a part of the body or the distance between two body surfaces, such as for measuring an excised skeletal specimen to determine the proper replacement size of a prosthesis. (b) Classification...

  11. 21 CFR 888.4150 - Calipers for clinical use.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ....4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... or diameter of a part of the body or the distance between two body surfaces, such as for measuring an excised skeletal specimen to determine the proper replacement size of a prosthesis. (b) Classification...

  12. 21 CFR 888.4150 - Calipers for clinical use.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ....4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... or diameter of a part of the body or the distance between two body surfaces, such as for measuring an excised skeletal specimen to determine the proper replacement size of a prosthesis. (b) Classification...

  13. 21 CFR 888.4150 - Calipers for clinical use.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ....4150 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... or diameter of a part of the body or the distance between two body surfaces, such as for measuring an excised skeletal specimen to determine the proper replacement size of a prosthesis. (b) Classification...

  14. Impact of meteorology, traffic characteristics, and distance from roadway on roadside concentrations of ultrafine particulate matter

    EPA Science Inventory

    Traffic-laden roadways are major contributors to poor air quality in developed areas, elevating pollutants such as particulate matter (PM) and ozone. Among the numerous air pollutants emitted by vehicles, ultrafine particles (UFPs, diameter <100 nm) are of interest as a potentia...

  15. Fiber optic muzzle brake tip for reducing fiber burnback and stone retropulsion during thulium fiber laser lithotripsy

    NASA Astrophysics Data System (ADS)

    Hutchens, Thomas C.; Gonzalez, David A.; Irby, Pierce B.; Fried, Nathaniel M.

    2017-01-01

    The experimental thulium fiber laser (TFL) is being explored as an alternative to the current clinical gold standard Holmium:YAG laser for lithotripsy. The near single-mode TFL beam allows coupling of higher power into smaller optical fibers than the multimode Holmium laser beam profile, without proximal fiber tip degradation. A smaller fiber is desirable because it provides more space in the ureteroscope working channel for increased saline irrigation rates and allows maximum ureteroscope deflection. However, distal fiber tip burnback increases as fiber diameter decreases. Previous studies utilizing hollow steel sheaths around recessed distal fiber tips reduced fiber burnback but increased stone retropulsion. A "fiber muzzle brake" was tested for reducing both fiber burnback and stone retropulsion by manipulating vapor bubble expansion. TFL lithotripsy studies were performed at 1908 nm, 35 mJ, 500 μs, and 300 Hz using a 100-μm-core fiber. The optimal stainless steel muzzle brake tip tested consisted of a 1-cm-long, 560-μm-outer-diameter, 360-μm-inner-diameter tube with a 275-μm-diameter through hole located 250 μm from the distal end. The fiber tip was recessed a distance of 500 μm. Stone phantom retropulsion, fiber tip burnback, and calcium oxalate stone ablation studies were performed ex vivo. Small stones with a mass of 40±4 mg and 4-mm-diameter were ablated over a 1.5-mm sieve in 25±4 s (n=10) without visible distal fiber tip burnback. Reduction in stone phantom retropulsion distance by 50% and 85% was observed when using muzzle brake tips versus 100-μm-core bare fibers and hollow steel tip fibers, respectively. The muzzle brake fiber tip simultaneously provided efficient stone ablation, reduced stone retropulsion, and minimal fiber degradation during TFL lithotripsy.

  16. Long-term evolution of 1991 DA: A dynamically evolved extinct Halley-type comet

    NASA Technical Reports Server (NTRS)

    Hahn, Gerhard; Bailey, M. E.

    1992-01-01

    The long-term dynamical evolution of 21 variational orbits for the intermediate-period asteroid 1991 DA was followed for up to +/-10(exp 5) years from the present. 1991 DA is close to the 2:7 resonance with Jupiter; it has avoided close encounters, within 1 AU, with this planet for at least the past 30,000 years, even at the node crossing. The future evolution typically shows no close encounters with Jupiter within at least 50,000 years. This corresponds to the mean time between node crossings with either Jupiter or Saturn. Close encounters with Saturn and Jupiter lead to a chaotic evolution for the whole ensemble, while secular perturbations cause large-amplitude swings in eccentricity and inclination (the latter covering the range 15 deg approximately less than i approximately less than 85 deg) which correlate with deep excursions of the perihelion distance to values much less than 1 AU. These variations are similar to those found in P/Machholz and a variety of other high-inclination orbits, e.g., P/Hartley-IRAS. We emphasize the connection between the orbital evolution of 1991 DA and that of Halley-type comets. If 1991 DA was once a comet, it is not surprising that it is now extinct.

  17. Acoustic positioning for space processing experiments

    NASA Technical Reports Server (NTRS)

    Whymark, R. R.

    1974-01-01

    An acoustic positioning system is described that is adaptable to a range of processing chambers and furnace systems. Operation at temperatures exceeding 1000 C is demonstrated in experiments involving the levitation of liquid and solid glass materials up to several ounces in weight. The system consists of a single source of sound that is beamed at a reflecting surface placed a distance away. Stable levitation is achieved at a succession of discrete energy minima contained throughout the volume between the reflector and the sound source. Several specimens can be handled at one time. Metal discs up to 3 inches in diameter can be levitated, solid spheres of dense material up to 0.75 inches diameter, and liquids can be freely suspended in l-g in the form of near-spherical droplets up to 0.25 inch diameter, or flattened liquid discs up to 0.6 inches diameter. Larger specimens may be handled by increasing the size of the sound source or by reducing the sound frequency.

  18. Ejector device for direct injection fuel jet

    DOEpatents

    Upatnieks, Ansis [Livermore, CA

    2006-05-30

    Disclosed is a device for increasing entrainment and mixing in an air/fuel zone of a direct fuel injection system. The device comprises an ejector nozzle in the form of an inverted funnel whose central axis is aligned along the central axis of a fuel injector jet and whose narrow end is placed just above the jet outlet. It is found that effective ejector performance is achieved when the ejector geometry is adjusted such that it comprises a funnel whose interior surface diverges about 7.degree. to about 9.degree. away from the funnel central axis, wherein the funnel inlet diameter is about 2 to about 3 times the diameter of the injected fuel plume as the fuel plume reaches the ejector inlet, and wherein the funnel length equal to about 1 to about 4 times the ejector inlet diameter. Moreover, the ejector is most effectively disposed at a separation distance away from the fuel jet equal to about 1 to about 2 time the ejector inlet diameter.

  19. Fabrication and magnetic properties of Fe nanostructures in anodic alumina membrane

    NASA Astrophysics Data System (ADS)

    Lim, J.-H.; Chae, W.-S.; Lee, H.-O.; Malkinski, L.; Min, S.-G.; Wiley, J. B.; Jun, J.-H.; Lee, S.-H.; Jung, J.-S.

    2010-05-01

    Several Fe nanostructures with different lengths, diameters, and separations of the constituting magnetic components have been synthesized using anodized alumina membranes (AAMs) to understand the influence of these parameters on their magnetic properties. Fe nanostructures with high crystallinity and (110) orientation were synthesized by electrodeposition at room temperature in regular AAMs and mild-hard AAM (Mi-Ha AAM). Fe nanostructures with different aspect ratios (1:1, 1:10, and 1:75) in the form of nanodots, nanorods, or nanowires were synthesized in regular AAMs with the 100 nm interpore distance. Mi-Ha AAMs with two different pore sizes (70 and 120 nm) and 250 nm interpore distances were used to investigate the effect of the interactions and of the diameter of the wires on their magnetic behavior. Nearly linear magnetization characteristics with small coercivity, observed for Fe nanowires, suggest the magnetization rotation to be the predominant magnetization process for the field applied transverse to the wires. The anisotropy of the arrays was governed by the shape anisotropy of the magnetic objects with different aspect ratios. Reduced interactions between the nanowires grown in Mi-Ha AAMs resulted in enhancement of the average anisotropy. It is believed that due to difference in spin configuration, the increased diameter of the nanowires led to reduction in the coercivity in the case of the field applied along the wires.

  20. Electrohydrodynamic (edh) drying of ginger slices (zingiber officinale)

    NASA Astrophysics Data System (ADS)

    Sumariyah; Khuriati, Ainie; Fachriyah, Enny

    2018-05-01

    Electrohydrodynamic (EHD) flow or ion wind of corona discharges has been generated utilizing pin-multi ring concentred electrodes. The pin was made of stainless steel with a tip diameter of 0.018 mm. The multi-ring constructed electrodes by a metal material connected to each other and each ring has a diameter of 24 mm, 16 mm and 8 mm in the same width and thickness is 4 mm and 1 mm. EHD was generated by using a DC high voltage of 5 kV. Pin as an active electrode of corona discharge and multi-ring concentric electrodes as a collector and passive electrodes. The ion wind or EHD flow is produced through changes in voltage and distance between electrodes. The ionic wind generated system outputs through multi-ring concentric electrodes which will further dry the sample. A circle ginger slices as a sample with a diameter of 26 mm with a thickness of 2 mm. The drying is done at the distance between the fixed electrodes of 4 mm and the varied voltages are 1.2 kV, 1.4 kV, and 1.6 kV. The sample drying time varied 30 minutes, 60 minutes, 90 minutes, 120 minutes and 150 minutes. The result of drying the sample at a fixed voltage is obtained moisture of ginger slices decreased with increased drying time.

  1. Chandra X-Ray Observatory Image of Eta Carinae

    NASA Technical Reports Server (NTRS)

    1999-01-01

    This Chandra X-Ray Observatory image of the mysterious superstar Eta Carinae reveals a surprising hot irner core, creating more questions than answers for astronomers. The image shows three distinct structures: An outer, horseshoe shaped ring about 2 light-years in diameter, a hot inner core about 3 light-months in diameter, and a hot central source less than a light-month in diameter which may contain the superstar. In 1 month, light travels a distance of approximately 489 billion miles (about 788 billion kilometers). All three structures are thought to represent shock waves produced by matter rushing away from the superstar at supersonic speeds. The temperature of the shock-heated gas ranges from 60 million degrees Kelvin in the central regions to 7 million degrees Kelvin on the outer structure. Eta Carinae is one of the most enigmatic and intriguing objects in our galaxy. Between 1837 and 1856, it increased dramatically in brightness to become the most prominent star in the sky except for Sirius, even through it is 7,500 light-years away, more than 80 times the distance to Sirius. This 'Great Eruption,' as it is called, had an energy comparable to a supernova, yet did not destroy the star, which faded to become a dim star, invisible to the naked eye. Since 1940, Eta Carinae has begun to brighten again, becoming visible to the naked eye. Photo credit: NASA/CXC/SAO

  2. Coulomb repulsion and the electron beam directed energy weapon

    NASA Astrophysics Data System (ADS)

    Retsky, Michael W.

    2004-09-01

    Mutual repulsion of discrete charged particles or Coulomb repulsion is widely considered to be an ultimate hard limit in charged particle optics. It prevents the ability to finely focus high current beams into small spots at large distances from defining apertures. A classic example is the 1970s era "Star Wars" study of an electron beam directed energy weapon as an orbiting antiballistic missile device. After much analysis, it was considered physically impossible to focus a 1000-amp 1-GeV beam into a 1-cm diameter spot 1000-km from the beam generator. The main reason was that a 1-cm diameter beam would spread to 5-m diameter at 1000-km due to Coulomb repulsion. Since this could not be overcome, the idea was abandoned. But is this true? What if the rays were reversed? That is, start with a 5-m beam converging slightly with the same nonuniform angular and energy distribution as the electrons from the original problem were spreading at 1000-km distance. Could Coulomb repulsion be overcome? Looking at the terms in computational studies, some are reversible while others are not. Based on estimates, the nonreversible terms should be small - of the order of 0.1 mm. If this is true, it is possible to design a practical electron beam directed weapon not limited by Coulomb repulsion.

  3. Analysis of pumping tests: Significance of well diameter, partial penetration, and noise

    USGS Publications Warehouse

    Heidari, M.; Ghiassi, K.; Mehnert, E.

    1999-01-01

    The nonlinear least squares (NLS) method was applied to pumping and recovery aquifer test data in confined and unconfined aquifers with finite diameter and partially penetrating pumping wells, and with partially penetrating piezometers or observation wells. It was demonstrated that noiseless and moderately noisy drawdown data from observation points located less than two saturated thicknesses of the aquifer from the pumping well produced an exact or acceptable set of parameters when the diameter of the pumping well was included in the analysis. The accuracy of the estimated parameters, particularly that of specific storage, decreased with increases in the noise level in the observed drawdown data. With consideration of the well radii, the noiseless drawdown data from the pumping well in an unconfined aquifer produced good estimates of horizontal and vertical hydraulic conductivities and specific yield, but the estimated specific storage was unacceptable. When noisy data from the pumping well were used, an acceptable set of parameters was not obtained. Further experiments with noisy drawdown data in an unconfined aquifer revealed that when the well diameter was included in the analysis, hydraulic conductivity, specific yield and vertical hydraulic conductivity may be estimated rather effectively from piezometers located over a range of distances from the pumping well. Estimation of specific storage became less reliable for piezemeters located at distances greater than the initial saturated thickness of the aquifer. Application of the NLS to field pumping and recovery data from a confined aquifer showed that the estimated parameters from the two tests were in good agreement only when the well diameter was included in the analysis. Without consideration of well radii, the estimated values of hydraulic conductivity from the pumping and recovery tests were off by a factor of four.The nonlinear least squares method was applied to pumping and recovery aquifer test data in confined and unconfined aquifers with finite diameter and partially penetrating piezometers and observation wells. Noiseless and moderately noisy drawdown data from observation points located less than two saturated thicknesses of the aquifer from the pumping well produced a set of parameters that agrees very well with piezometer test data when the diameter of the pumping well was included in the analysis. The accuracy of the estimated parameters decreased with increasing noise level.

  4. GEODSS Tracking Results on Asteroid 2012 DA14

    DTIC Science & Technology

    2013-06-12

    PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Air...Force Space Command,Det 3, 21st Operations Group (OG),Maui,HI,96753 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME...they performed utilizing known cases of this occurrence, they had concluded that a Natural Earth Satellite (NES) of 1meter diameter should be

  5. Calmyonemin: a 23 kDa analogue of algal centrin occurring in contractile myonemes of Eudiplodinium maggii (ciliate).

    PubMed

    David, C; Viguès, B

    1994-01-01

    Myonemes are bundles of thin filaments (3-6 nm in diameter) which mediate calcium-induced contraction of the whole or only parts of the cell body in a number of protists. In Eudiplodinium maggii, a rumen ciliate which lacks a uniform ciliation of the cell body, myonemes converge toward the bases of apical ciliary zones that can be retracted under stress conditions, entailing immobilization of the cell. An mAB (A69) has been produced that identifies a calcium-binding protein by immunoblot, immunoprecipitation experiments and specifically labels the myonemes in immunoelectron microscopy. Solubility properties, apparent molecular weight (23 kDa) and isoelectric point (4.9) of the myonemal protein, are similar to the values reported for the calcium-modulated contractile protein centrin. Western-blot analysis indicates that the 23 kDa protein cross-reacts antigenically with anti-centrin antibodies. In addition, the 23 kDa protein displays calcium-induced changes in both electrophoretic and chromatographic behaviour, and contains calcium-binding domains that conform to the EF-hand structure, as known for centrin. Based on these observations, we conclude that a calcium-binding protein with major similarities to centrin occurs in the myonemes of E. maggii. We postulate that this protein plays an essential role in myoneme-mediated retraction of the ciliature.

  6. The role of transparency in da Vinci stereopsis.

    PubMed

    Zannoli, Marina; Mamassian, Pascal

    2011-10-15

    The majority of natural scenes contains zones that are visible to one eye only. Past studies have shown that these monocular regions can be seen at a precise depth even though there are no binocular disparities that uniquely constrain their locations in depth. In the so-called da Vinci stereopsis configuration, the monocular region is a vertical line placed next to a binocular rectangular occluder. The opacity of the occluder has been mentioned to be a necessary condition to obtain da Vinci stereopsis. However, this opacity constraint has never been empirically tested. In the present study, we tested whether da Vinci stereopsis and perceptual transparency can interact using a classical da Vinci configuration in which the opacity of the occluder varied. We used two different monocular objects: a line and a disk. We found no effect of the opacity of the occluder on the perceived depth of the monocular object. A careful analysis of the distribution of perceived depth revealed that the monocular object was perceived at a depth that increased with the distance between the object and the occluder. The analysis of the skewness of the distributions was not consistent with a double fusion explanation, favoring an implication of occlusion geometry in da Vinci stereopsis. A simple model that includes the geometry of the scene could account for the results. In summary, the mechanism responsible to locate monocular regions in depth is not sensitive to the material properties of objects, suggesting that da Vinci stereopsis is solved at relatively early stages of disparity processing. Copyright © 2011 Elsevier Ltd. All rights reserved.

  7. Volume Transmission in Central Dopamine and Noradrenaline Neurons and Its Astroglial Targets.

    PubMed

    Fuxe, Kjell; Agnati, Luigi F; Marcoli, Manuela; Borroto-Escuela, Dasiel O

    2015-12-01

    Already in the 1960s the architecture and pharmacology of the brainstem dopamine (DA) and noradrenaline (NA) neurons with formation of vast numbers of DA and NA terminal plexa of the central nervous system (CNS) indicated that they may not only communicate via synaptic transmission. In the 1980s the theory of volume transmission (VT) was introduced as a major communication together with synaptic transmission in the CNS. VT is an extracellular and cerebrospinal fluid transmission of chemical signals like transmitters, modulators etc. moving along energy gradients making diffusion and flow of VT signals possible. VT interacts with synaptic transmission mainly through direct receptor-receptor interactions in synaptic and extrasynaptic heteroreceptor complexes and their signaling cascades. The DA and NA neurons are specialized for extrasynaptic VT at the soma-dendrtitic and terminal level. The catecholamines released target multiple DA and adrenergic subtypes on nerve cells, astroglia and microglia which are the major cell components of the trophic units building up the neural-glial networks of the CNS. DA and NA VT can modulate not only the strength of synaptic transmission but also the VT signaling of the astroglia and microglia of high relevance for neuron-glia interactions. The catecholamine VT targeting astroglia can modulate the fundamental functions of astroglia observed in neuroenergetics, in the Glymphatic system, in the central renin-angiotensin system and in the production of long-distance calcium waves. Also the astrocytic and microglial DA and adrenergic receptor subtypes mediating DA and NA VT can be significant drug targets in neurological and psychiatric disease.

  8. Fast and robust shape diameter function.

    PubMed

    Chen, Shuangmin; Liu, Taijun; Shu, Zhenyu; Xin, Shiqing; He, Ying; Tu, Changhe

    2018-01-01

    The shape diameter function (SDF) is a scalar function defined on a closed manifold surface, measuring the neighborhood diameter of the object at each point. Due to its pose oblivious property, SDF is widely used in shape analysis, segmentation and retrieval. However, computing SDF is computationally expensive since one has to place an inverted cone at each point and then average the penetration distances for a number of rays inside the cone. Furthermore, the shape diameters are highly sensitive to local geometric features as well as the normal vectors, hence diminishing their applications to real-world meshes which often contain rich geometric details and/or various types of defects, such as noise and gaps. In order to increase the robustness of SDF and promote it to a wide range of 3D models, we define SDF by offsetting the input object a little bit. This seemingly minor change brings three significant benefits: First, it allows us to compute SDF in a robust manner since the offset surface is able to give reliable normal vectors. Second, it runs many times faster since at each point we only need to compute the penetration distance along a single direction, rather than tens of directions. Third, our method does not require watertight surfaces as the input-it supports both point clouds and meshes with noise and gaps. Extensive experimental results show that the offset-surface based SDF is robust to noise and insensitive to geometric details, and it also runs about 10 times faster than the existing method. We also exhibit its usefulness using two typical applications including shape retrieval and shape segmentation, and observe a significant improvement over the existing SDF.

  9. Morphometric analysis of diameter and relationship of vertebral artery with respect to transverse foramen in Indian population

    PubMed Central

    Sureka, Binit; Mittal, Mahesh Kumar; Mittal, Aliza; Agarwal, Mukul Sinha Kanhaiya; Bhambri, Narendra Kumar; Thukral, Brij Bhushan

    2015-01-01

    Purpose: To study the location, origin, size and relationship of the vertebral artery and the transverse foramina in the lower cervical spine by computed tomographic angiography (CTA) measurements in the Indian population. Materials and Methods: A retrospective review of multi-detector CT (MDCT) cerebral angiography scans was done between June 2011 and February 2014. A total of 120 patients were evaluated. The diameter of the vertebral artery (AL) and the shortest distance between the vertebral artery and the medial (M), lateral (L), anterior (A), and posterior (P) borders of transverse foramen were studied. In addition, the shortest distance between the vertebral artery and pedicle (h) was also analyzed. Statistical Analysis: The means and their standard deviations (SD) were calculated in both the sexes. The t-tests were performed to look for significant sexual difference. Results: The largest vertebral artery diameter (AL) was at level C7 on the right side (3.5 ± 0.8) and at the level of C5 on the left side (3.7 ± 0.4). Statistically significant difference between males and females were seen at levels C4, C5, and C7. The diameter of the vertebral artery was smaller in females than males. The L value was greater than other parameters (M, A, P) at the same level in all the measurements. The h value was greatest at C6 level and shortest at C5. Conclusion: CTA is necessary before pedicle screw fixation due to variation in measurements at all levels. The highest potential risk of vertebral artery injury during cervical pedicle screw implantation may be at C5, then at C4, and the safest is at C7. PMID:25969640

  10. Calculating the number of shock waves, expulsion time, and optimum stone parameters based on noncontrast computerized tomography characteristics.

    PubMed

    Foda, Khaled; Abdeldaeim, Hussein; Youssif, Mohamed; Assem, Akram

    2013-11-01

    To define the parameters that accompanied a successful extracorporeal shock wave lithotripsy (ESWL), namely the number of shock waves (SWs), expulsion time (ET), mean stone density (MSD), and the skin-to-stone distance (SSD). A total of 368 patients diagnosed with renal calculi using noncontrast computerized tomography had their MSD, diameter, and SSD recorded. All patients were treated using a Siemens lithotripter. ESWL success meant a stone-free status or presence of residual fragments <3 mm, ET was the time in days for the successful clearance of stone fragments. Correlation was performed between the stone characteristics, number of SWs, and ET. Two multiple regression analysis models defined the number of SWs and ET. Two receiver operating characteristic curves plotted the best MSD cutoff value and optimum SSD for a successful ESWL. Three hundred one patients were ESWL successes. A significant positive correlation was elicited between number of SWs and stone diameter, density and SSD; between ET and stone diameter and density. Multiple regressions concluded 2 equations: Number of SWs = 265.108 + 5.103 x1 + 22.39 x2 + 10.931 x3 ET (days) = -10.85 + 0.031 x1 + 2.11 x2 x1 = stone density (Hounsfield unit [HUs]), x2 = stone diameter (mm), and x3 = SSD (mm). Receiver operating characteristic curves demonstrated a cutoff value of ≤ 934 HUs with 94.4% sensitivity and 66.7% specificity and P = .0211. The SSD curve showed that a distance ≤ 99 mm was 85.7% sensitive, 87.5% specific, P <.0001. Stone disintegration is not recommended if MSD is >934 HUs and SSD >99 mm. The required number of SWs and the expected ET can be anticipated. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. A microfabricated hybrid device for DNA sequencing.

    PubMed

    Liu, Shaorong

    2003-11-01

    We have created a hybrid device of a microfabricated round-channel twin-T injector incorporated with a separation capillary in order to extend the straight separation distance for high speed and long readlength DNA sequencing. Semicircular grooves on glass wafers are obtained using a photomask with a narrow line-width and a standard isotropic photolithographic etching process. Round channels are made when two etched wafers are face-to-face aligned and bonded. A two-mask fabrication process has been developed to make channels of two different diameters. The twin-T injector is formed by the smaller channels whose diameter matches the bore of the separation capillary, and the "usual" separation channel, now called the connection channel, is formed by the larger ones whose diameter matches the outer diameter of the separation capillary. The separation capillary is inserted through the connection channel all the way to the twin-T injector to allow the capillary bore flush with the twin-T injector channels. The total dead-volume of the connection is estimated to be approximately 5 pL. To demonstrate the efficiency of this hybrid device, we have performed four-color DNA sequencing on it. Using a 200 microm twin-T injector coupled with a separation capillary of 20 cm effective separation distance, we have obtained readlengths of 800 plus bases at an accuracy of 98.5% in 56 min, compared to about 650 bases in 100 min on a conventional 40 cm long capillary sequencing machine under similar conditions. At an increased separation field strength and using a diluted sieving matrix, the separation time has been reduced to 20 min with a readlength of 700 bases at 98.5% base-calling accuracy.

  12. Treatment of cells with alkaline borate buffer extends the capability of interphase FISH mapping.

    PubMed

    Yokota, H; van den Engh, G; Mostert, M; Trask, B J

    1995-01-20

    Interphase fluorescence in situ hybridization (FISH) has been shown to be a means to map DNA sequences relative to each other in the 100 kb to 1-2 Mb genomic-separation range. At distances below 0.1 Mb, probe sites are infrequently resolved in interphase chromatin. In the 0.1- to 1-Mb range, interphase chromatin can be modeled as a freely flexible chain. The mean square interphase distance between two probes is proportional to the genomic separation between the probes on the linear DNA molecule. Above 1-2 Mb, the relationship between interphase distance and genomic separation changes abruptly and appears to level off. We have used alkaline-borate treatment to expand the capability of interphase FISH mapping. We show here that alkaline-borate treatment increases nuclear diameter, the interphase distance between probes on homologous chromosomes, and the distance between probes on the same chromosome. We also show that the mean square distance between hybridization sites in borate-treated nuclei is proportional to genomic separation up to 4 Mb. Thus, alkaline-borate treatment enhances the capability of interphase FISH mapping by increasing the absolute distance between probes and extending the range of the simple relationship between interphase distance and genomic separation.

  13. Treatment of cells with alkaline borate buffer extends the capability of interphase FISH mapping

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Yokota, H.; Van Den Engh, G.; Mostert, M.

    1995-01-20

    Interphase fluorescence in situ hybridization (FISH) has been shown to be a means to map DNA sequences relative to each other in the 100 kb to 1-2 Mb genomic-separation range. At distances below 0.1 Mb, probe sites are infrequently resolved in interphase chromatin. In the 0.1- to 1-Mb range, interphase chromatin can be modeled as a freely flexible chain. The mean square interphase distance between two probes is proportional to the genomic separation between the probes on the linear DNA molecule. Above 1-2 Mb, the relationship between interphase distance and genomic separation changes abruptly and appears to level off. Wemore » have used alkaline-borate treatment to expand the capability of interphase FISH mapping. We show here that alkaline-borate treatment increases nuclear diameter, the interphase distance between probes on homologous chromosomes, and the distance between probes on the same chromosome. We also show that the mean square distance between hybridization sites in borate-treated nuclei is proportional to genomic separation up to 4 Mb. Thus, alkaline-borate treatment enhances the capability of interphase FISH mapping by increasing the absolute distance between probes and extending the range of the simple relationship between interphase distance and genomic separation. 31 refs., 5 figs.« less

  14. Formation of self-ordered porous anodized alumina template for growing tungsten trioxide nanowires

    NASA Astrophysics Data System (ADS)

    Hussain, Tajamal; Shah, Asma Tufail; Shehzad, Khurram; Mujahid, Adnan; Farooqi, Zahoor Hussain; Raza, Muhammad Hamid; Ahmed, Mirza Nadeem; Nisa, Zaib Un

    2015-12-01

    Uniform porous anodized aluminum oxide (AAO) membrane has been synthesized by two-step anodization for fabricating tungsten trioxide (WO3) nanowires. Under assayed conditions, uniform porous structure of alumina (Al2O3) membrane with long range ordered hexagonal arrangements of nanopores was achieved. The self-assembled template possesses pores of internal diameter of 50 nm and interpore distance ( d int) of 80 nm with a thickness of about 80 µm, i.e., used for fabrication of nanostructures. WO3 nanowires have been fabricated by simple electroless deposition method inside Al2O3 nanopores. SEM images show tungsten trioxide nanowire with internal diameter of about 50 nm, similar to porous diameter of AAO template. XRD results showed that nanowires exist in cubic crystalline state with minor proportion of monoclinic phase.

  15. Influence of process conditions during impulsed electrostatic droplet formation on size distribution of hydrogel beads.

    PubMed

    Lewińska, Dorota; Rosiński, Stefan; Weryński, Andrzej

    2004-02-01

    In the medical applications of microencapsulation of living cells there are strict requirements concerning the high size uniformity and the optimal diameter, the latter dependent on the kind of therapeutic application, of manufactured gel beads. The possibility of manufacturing small size gel bead samples (diameter 300 microm and below) with a low size dispersion (less than 10%), using an impulsed voltage droplet generator, was examined in this work. The main topic was the investigation of the influence of values of electric parameters (voltage U, impulse time tau and impulse frequency f) on the quality of obtained droplets. It was concluded that, owing to the implementation of the impulse mode and regulation of tau and f values, it is possible to work in a controlled manner in the jet flow regime (U> critical voltage UC). It is also possible to obtain uniform bead samples with the average diameter, deff, significantly lower than the nozzle inner diameter dI (bead diameters 0.12-0.25 mm by dI equal to 0.3 mm, size dispersion 5-7%). Alterations of the physical parameters of the process (polymer solution physico-chemical properties, flow rate, distance between nozzle and gellifying bath) enable one to manufacture uniform gel beads in the wide range of diameters using a single nozzle.

  16. Electromagnetic Launching for Affordable Agile Access to Space

    DTIC Science & Technology

    2006-04-15

    requirements are advantageous compared to other EM launch technologies. 14 I Pp TRI TF1 (P) TR2 TF2 (P) ... TRM TFM (P) TF1 TRI(n) TF2 TH .)񔰣 -n F- on 71...some integer M. The distance between the rear coil TRI and the corresponding front coil TF1 is MxPT. PP: distance between coils in the projectile, PT...TRI with TFI/p), TR2 with TF2(P) ..., and also TR/("),with TF1 , TR2(n)with TF2, etc. ). * For a slender projectile (i.e. length >> diameter), it is

  17. A laser system to remotely sense bird movements

    NASA Technical Reports Server (NTRS)

    Korschgen, C. E.; Green, W. L.; Seasholtz, R. G.

    1983-01-01

    The design and operation of a laser detection system for migrating birds are presented. A battery-powered class-III laser (operating at 904 nm, pulse-repetition rate 5 kHz, pulse duration 100 nsec, and peak power 25 W) and a photodiode receiver are mounted on poles at height 10 m and distance 850 m and equipped with 135-mm f/2.8 collimating lenses; beam diameter at the receiver is 1.7 m. The microprocessor-controlled system is found to detect the passing of an object as small as 30 sq cm in cross section at a distance of 425 m.

  18. Energy scaling of passively Q-switched lasers In the Mj-range

    NASA Astrophysics Data System (ADS)

    Neumann, J.; Huss, R.; Kolleck, C.; Kracht, Dietmar

    2017-11-01

    Q-switched lasers systems with ns pulse duration and energies ranging from 1 to more than 100mJ are utilized for many spaceborne applications such as altimetry of planets and moons. Furthermore, Q-switched lasers can be used for distance measurements during docking and landing manoeuvres. To keep the diameter of the beam small over a large distance and to consequently achieve a good lateral resolution, a good beam propagation factor M² is required. Moreover, Q-switched lasers can be used directly on the planetary surface for exploration by laser-induced breakdown spectroscopy or laser desorption mass spectrometry.

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lavinto, Mikko; Räsänen, Syksy, E-mail: mikko.lavinto@helsinki.fi, E-mail: syksy.rasanen@iki.fi

    We consider a Swiss Cheese model with a random arrangement of Lemaȋtre-Tolman-Bondi holes in ΛCDM cheese. We study two kinds of holes with radius r{sub b}=50 h{sup −1} Mpc, with either an underdense or an overdense centre, called the open and closed case, respectively. We calculate the effect of the holes on the temperature, angular diameter distance and, for the first time in Swiss Cheese models, shear of the CMB . We quantify the systematic shift of the mean and the statistical scatter, and calculate the power spectra. In the open case, the temperature power spectrum is three orders of magnitude belowmore » the linear ISW spectrum. It is sensitive to the details of the hole, in the closed case the amplitude is two orders of magnitude smaller. In contrast, the power spectra of the distance and shear are more robust, and agree with perturbation theory and previous Swiss Cheese results. We do not find a statistically significant mean shift in the sky average of the angular diameter distance, and obtain the 95% limit |Δ D{sub A}/ D-bar {sub A}|∼< 10{sup −4}. We consider the argument that areas of spherical surfaces are nearly unaffected by perturbations, which is often invoked in light propagation calculations. The closed case is consistent with this at 1σ, whereas in the open case the probability is only 1.4%.« less

  20. Spatial patterns of a tropical tree species growing under an eucalyptus plantation in South-East Brazil.

    PubMed

    Higuchi, P; Silva, A C; Louzada, J N C; Machado, E L M

    2010-05-01

    The objectives of this study were to evaluate the influence of propagules source and the implication of tree size class on the spatial pattern of Xylopia brasiliensis Spreng. individuals growing under the canopy of an experimental plantation of eucalyptus. To this end, all individuals of Xylopia brasiliensis with diameter at soil height (dsh) > 1 cm were mapped in the understory of a 3.16 ha Eucalyptus spp. and Corymbia spp. plantation, located in the municipality of Lavras, SE Brazil. The largest nearby mature tree of X. brasiliensis was considered as the propagules source. Linear regressions were used to assess the influence of the distance of propagules source on the population parameters (density, basal area and height). The spatial pattern of trees was assessed through the Ripley K function. The overall pattern showed that the propagules source distance had strong influence over spatial distribution of trees, mainly the small ones, indicating that the closer the distance from the propagules source, the higher the tree density and the lower the mean tree height. The population showed different spatial distribution patterns according to the spatial scale and diameter class considered. While small trees tended to be aggregated up to around 80 m, the largest individuals were randomly distributed in the area. A plausible explanation for observed patterns might be limited seed rain and intra-population competition.

  1. Evaluation of effervescent atomizer internal design on the spray unsteadiness using a phase/Doppler particle analyzer

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Meng; Duan, YuFeng; Zhang, TieNan

    2010-09-15

    The purpose of this research was to investigate the dependence of effervescent spray unsteadiness on operational conditions and atomizer internal design by the ideal spray theory of Edwards and Marx. The convergent-divergent effervescent atomizer spraying water with air as atomizing medium in the ''outside-in'' gas injection was used in this study. Results demonstrated that droplet formation process at various air to liquid ratio (ALR) led to the spray unsteadiness and all droplet size classes exhibited unsteadiness behavior in spray. The spray unsteadiness reduced quickly at ALR of 3% and decreased moderately at ALR of other values as the axial distancemore » increased. When the axial distance was 200 mm, the spray unsteadiness reduced dramatically with the increase in radial distance, but lower spray unsteadiness at the center of spray and higher spray unsteadiness at the edge of spray were shown as the axial distance increased. The spray unsteadiness at the center region of spray increased with the injection pressure. Low spray unsteadiness and good atomization performance can be obtained when the diameter of incline aeration holes increased at ALR of 10%. Although short mixing chamber with large discharge orifice diameter for convergent-divergent effervescent atomizer produced good atomization, the center region of spay showed high spray unsteadiness and maybe formed the droplet clustering. (author)« less

  2. Space missions for SETI.

    PubMed

    Drake, F

    1999-01-01

    Radio Telescopes for SETI searches are less demanding than general purpose astronomical radio telescopes. This provides an opportunity to exploit economical approaches in designing SETI systems. Radio Telescopes in low Earth orbit offer no discernible advantages to SETI; indeed, they probably would perform more poorly than a telescope in any other location. Telescopes in geosynchronous orbits would be sufficiently far from Earth to mitigate greatly the deleterious effect of human radio transmissions. Telescopes on the far side of the moon would be superb both from a radio interference standpoint, and from a civil engineering standpoint. Single-reflector telescopes as large as 50 kilometers in diameter could be constructed with conventional materials. However, their costs appear prohibitive. The asteroid belt and the outer solar system are unpromising places to place a large radio telescope. Perhaps the ultimate radio telescope would utilize the sun as a gravitational lens, focusing radiation on free-flying 10-meter class or possibly larger radio telescopes located at distances of the order of 1000 A.U. from the sun. Such a combination has an energy collecting area at 10 centimeters wavelength equivalent to that of a radio telescope about 11 kilometers in diameter, or of the order of 3000 Arecibo radio telescopes. Such a system could detect transmitters with EIRP of the order of a gigawatt at a distance of the order of the distance to the galactic center.

  3. The registered distance of the celestial sphere: some historical cross-cultural data.

    PubMed

    Plug, C

    1989-02-01

    Estimates of the diameters of the sun and moon expressed in centimetres have been reported by several authors in the past. These estimates imply that the sizes of the sun and moon are perceived as if these bodies are only some tens of metres distant. In this study five units of length that were used by ancient astronomers to estimate arcs on the celestial sphere were investigated. The purpose was to determine whether the lengths and angles represented by these units imply a specific registered distance of the star sphere. The sizes of the Babylonian cubit, Arab fitr and shibr, Greek eclipse digit, and Chinese chang support the conclusion that the registered distance of the stars was about 10 to 40 metres in these four cultures over the last two millennia.

  4. 30 CFR 75.221 - Roof control plan information.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... main roof above the coalbed and for distance of at least 10 feet below the coalbed; and (iii) Indicate... the liners or arches. (8) Drawings indicating the planned width of openings, size of pillars, method...) The length, diameter, grade and type of anchorage unit to be used; (ii) The drill hole size to be used...

  5. 30 CFR 75.221 - Roof control plan information.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... main roof above the coalbed and for distance of at least 10 feet below the coalbed; and (iii) Indicate... the liners or arches. (8) Drawings indicating the planned width of openings, size of pillars, method...) The length, diameter, grade and type of anchorage unit to be used; (ii) The drill hole size to be used...

  6. Multiple-bolted joints in wood members : a literature review

    Treesearch

    Peter James Moss

    1997-01-01

    This study reviewed the literature on experimental and analytical research for the connection of wood members using multiple laterally loaded bolts. From this, the influence of geometric factors were ascertained, such as staggered and aligned fasteners, optimum fastener configurations, row factors and length-to-diameter bolt ratios, spacing, end and edge distances, and...

  7. ACOUSTIC LOCATION OF LEAKS IN PRESSURIZED UNDERGROUND PETROLEUM PIPELINES

    EPA Science Inventory

    Experiments were conducted at the UST Test Apparatus Pipeline in which three acoustic sensors separated by a maximum distance of 38 m (125-ft) were used to monitor signals produced by 3.0-, 1.5-, and 1.0-gal/h leaks in the wall of a 2-in.-diameter pressurized petroleum pipeline. ...

  8. Distribution of end bearing, tip shear and rotation on drilled shafts with combined loading in Florida limestone : final report, May 2008.

    DOT National Transportation Integrated Search

    2008-05-01

    The study investigated the behavior of large diameter drilled shafts embedded short distances in Florida Limestone (i.e. L/D=1 &3). The work was performed via laboratory (centrifuge) tests and at two field sites (17th Street and Fuller Warren Bridges...

  9. Key algorithms used in GR02: A computer simulation model for predicting tree and stand growth

    Treesearch

    Garrett A. Hughes; Paul E. Sendak; Paul E. Sendak

    1985-01-01

    GR02 is an individual tree, distance-independent simulation model for predicting tree and stand growth over time. It performs five major functions during each run: (1) updates diameter at breast height, (2) updates total height, (3) estimates mortality, (4) determines regeneration, and (5) updates crown class.

  10. A review of past research on dendrometers

    Treesearch

    Neil Clark; Randolph H. Wynne; Daniel L. Schmoldt

    2000-01-01

    The purpose of a dendrometer is to measure tree diameter. Contact and noncontact dendrometers accomplish this task by collecting different metrics, including girth or distance between tangent points on a tree stem. Many dendrometers have been developed in the last quarter century and many have been retired. This article summarizes instrument developments and...

  11. Discontinuous permeable adsorptive barrier design and cost analysis: a methodological approach to optimisation.

    PubMed

    Santonastaso, Giovanni Francesco; Bortone, Immacolata; Chianese, Simeone; Di Nardo, Armando; Di Natale, Michele; Erto, Alessandro; Karatza, Despina; Musmarra, Dino

    2017-09-19

    The following paper presents a method to optimise a discontinuous permeable adsorptive barrier (PAB-D). This method is based on the comparison of different PAB-D configurations obtained by changing some of the main PAB-D design parameters. In particular, the well diameters, the distance between two consecutive passive wells and the distance between two consecutive well lines were varied, and a cost analysis for each configuration was carried out in order to define the best performing and most cost-effective PAB-D configuration. As a case study, a benzene-contaminated aquifer located in an urban area in the north of Naples (Italy) was considered. The PAB-D configuration with a well diameter of 0.8 m resulted the best optimised layout in terms of performance and cost-effectiveness. Moreover, in order to identify the best configuration for the remediation of the aquifer studied, a comparison with a continuous permeable adsorptive barrier (PAB-C) was added. In particular, this showed a 40% reduction of the total remediation costs by using the optimised PAB-D.

  12. Nonlinear quasi-static analysis of ultra-deep-water top-tension riser

    NASA Astrophysics Data System (ADS)

    Gao, Guanghai; Qiu, Xingqi; Wang, Ke; Liu, Jianjun

    2017-09-01

    In order to analyse the ultra-deep-water top-tension riser deformation in drilling conditions, a nonlinear quasi-static analysis model and equation are established. The riser in this model is regarded as a simply supported beam located in the vertical plane and is subjected to non-uniform axial and lateral forces. The model and the equation are solved by the finite element method. The effects of riser outside diameter, top tension ratio, sea surface current velocity, drag force coefficient, floating system drift distance and water depth on the riser lateral displacement are discussed. Results show that the riser lateral displacement increase with the increase in the sea surface current velocity, drag force coefficient and water depth, whereas decrease with the increase in the riser outside diameter, top tension ratio. The top tension ratio has an important influence on the riser deformation and it should be set reasonably under different circumstances. The drift of the floating system has a complicated influence on the riser deformation and it should avoid a large drift distance in the proceedings of drilling and production.

  13. Galaxy clusters, type Ia supernovae and the fine structure constant

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Holanda, R.F.L.; Busti, V.C.; Colaço, L.R.

    2016-08-01

    As is well known, measurements of the Sunyaev-Zeldovich effect can be combined with observations of the X-ray surface brightness of galaxy clusters to estimate the angular diameter distance to these structures. In this paper, we show that this technique depends on the fine structure constant, α. Therefore, if α is a time-dependent quantity, e.g., α = α{sub 0}φ( z ), where φ is a function of redshift, we argue that current data do not provide the real angular diameter distance, D {sub A}( z ), to the cluster, but instead D {sub A}{sup data}( z ) = φ( z ){supmore » 2} D {sub A}( z ). We use this result to derive constraints on a possible variation of α for a class of dilaton runaway models considering a sample of 25 measurements of D {sub A}{sup data}( z ) in redshift range 0.023 < z < 0.784 and estimates of D {sub A}( z ) from current type Ia supernovae observations. We find no significant indication of variation of α with the present data.« less

  14. Measurements of eight early-type stars angular diameters using VEGA/CHARA interferometer

    NASA Astrophysics Data System (ADS)

    Challouf, M.; Nardetto, N.; Mourard, D.; Aroui, H.; Delaa, O.

    2014-12-01

    The surface brightness color (SBC) relation is an important tool to derive the distance of extragalatic eclipsing binaries. We determined the uniform disc angular diameter of the eight following early-type stars using VEGA/CHARA interferometric observations: θ_{UD}[δ Cyg] = 0.766 ± 0.047 mas, θ_{UD}[γ Lyr] = 0.742& ± 0.010 mas, θ_{UD}[γ Ori] = 0.701 ± 0.005 mas, θ_{UD}[ζ Peg] = 0.539 ± 0.009 mas, θ_{UD}[λ Aql] = 0.529 ± 0.003 mas, θ_{UD}[ζ Per] = 0.531 ± 0.007 mas, θ_{UD}[ι Her] = 0.304 ± 0.010 mas and θ_{UD}[8 Cyg] = 0.229 ± 0.011 mas (by extending V-K range from -0.76 to 0.02) with typical precision of about 1.5%. By combining these data with previous angular diameter determinations available in the literature, Challouf et al. (2014) provide for the very first time a SBC relation for early-type stars (-1≤V-K≤0) with a precision of about 0.16 magnitude or 7% in term of angular diameter (when using this SBC relation to derive the angular diameter of early-type stars).

  15. Tuning aggregation of microemulsion droplets and silica nanoparticles using solvent mixtures.

    PubMed

    Salabat, Alireza; Eastoe, Julian; Mutch, Kevin J; Tabor, Rico F

    2008-02-15

    The effect of solvent on stability of water-in-oil microemulsions has been studied with AOT (sodium bis(2-ethylhexyl)sulfosuccinate) and different solvent mixtures of n-heptane, toluene and dodecane. Dynamic light scattering DLS was used to monitor the apparent diffusion coefficient D(A) and effective microemulsion droplet diameter on changing composition of the solvent. Interdroplet attractive interactions, as indicated by variations in D(A), can be tuned by formulation of appropriate solvent mixtures using heptane, toluene, and dodecane. In extreme cases, solvent mixtures can be used to induce phase transitions in the microemulsions. Aggregation and stability of model AOT-stabilized silica nanoparticles in different solvents were also investigated to explore further these solvent effects. For both systems the state of aggregation can be correlated with the effective molecular volume of the solvent V(mol)(eff) mixture.

  16. Surface temperature and thermal penetration depth of Nd:YAG laser applied to enamel and dentin

    NASA Astrophysics Data System (ADS)

    White, Joel M.; Neev, Joseph; Goodis, Harold E.; Berns, Michael W.

    1992-06-01

    The determination of the thermal effects of Nd:YAG laser energy on enamel and dentin is critical in understanding the clinical applications of caries removal and surface modification. Recently extracted non-carious third molars were sterilized with gamma irradiation. Calculus and cementum were removed using scaling instruments and 600 grit sand paper. The smear layer produced by sanding was removed with a solution of 0.5 M EDTA (pH 7.4) for two minutes. Enamel and dentin surfaces were exposed to a pulsed Nd:YAG laser with 150 microsecond(s) pulse duration. Laser energy was delivered to the teeth with a 320 micrometers diameter fiberoptic delivery system, for exposure times of 1, 10 and 30 seconds. Laser parameters varied from 0.3 to 3.0 W, 10 to 30 Hz and 30 to 150 mJ/pulse. Other conditions included applications of hot coffee, carbide bur in a dental air-cooled turbine drill and soldering iron. Infrared thermography was used to measure the maximum surface temperature on, and thermal penetration distance into enamel and dentin. Thermographic data were analyzed with a video image processor to determine the diameter of maximum surface temperature and thermal penetration distance of each treatment. Between/within statistical analysis of variance (p

  17. X-ray optics made from thin plastic foils

    NASA Astrophysics Data System (ADS)

    Schnopper, Herbert W.; Silver, Eric H.; Ingram, Russell H.; Christensen, Finn E.; Hussain, Ahsen M.; Barbera, Marco; Romaine, Suzanne E.; Collura, Alfonso; Kenter, Almus T.; Bandler, Simon; Murray, Stephen S.

    1999-09-01

    New design concepts and materials can be used to produce very lightweight, thin foil approximations, to Wolter I and other x-ray optics. Structures are designed around a central hub and spacers that connect one spoked wheels. Figure defining, thin pins span the distance between the wheels. Thin, metal coated or multilayered, plastic foils can be formed into cones, cylinders or spirals for x-ray telescopes or lenses. Imaging and spectroscopic data obtained with x- ray lenses are presented and they indicate that a 60 cm diameter, 4.65 m focal length x-ray telescope can have a half power diameter of < 2 arcmin.

  18. Resinless section electron microscopy reveals the yeast cytoskeleton.

    PubMed

    Penman, J; Penman, S

    1997-04-15

    The cytoskeleton of Saccharomyces cerevisiae is essentially invisible using conventional microscopy techniques. A similar problem was solved for the mammalian cell cytoskeleton using resinless section electron microscopy, a technique applied here to yeast. In the resinless image, soluble proteins are no longer cloaked by embedding medium and must be removed by selective detergent extraction. In yeast, this requires breaching the cell wall by digesting with Zymolyase sufficiently to allow detergent extraction of the plasma membrane lipids. Gel electropherograms show that the extracted or "soluble" proteins are distinct from the retained or "structural" proteins that presumably comprise the cytoskeleton. These putative cytoskeleton proteins include the major portions of a 43-kDa protein, which is presumably actin, and of proteins in a band appearing at 55 kDa, as well as numerous less abundant, nonactin proteins. Resinless section electron micrographs show a dense, three-dimensional web of anastomosing, polymorphic filaments bounded by the remnant cell wall. Although the filament network is very heterogenous, there appear to be two principal classes of filament diameters-5 nm and 15-20 nm-which may correspond to actin and intermediate filaments, respectively. A large oval region of lower filament density probably corresponds to the vacuole, and an electron dense spheroidal body, 300-500 nm in diameter, is likely the nucleus. The techniques detailed in this report afford new approaches to the study of yeast cytoarchitecture.

  19. Protection of dopamine towards autoxidation reaction by encapsulation into non-coated- or chitosan- or thiolated chitosan-coated-liposomes.

    PubMed

    Trapani, A; Mandracchia, D; Tripodo, G; Cometa, S; Cellamare, S; De Giglio, E; Klepetsanis, P; Antimisiaris, S G

    2018-05-26

    The aim of this work is to evaluate the potential of non-coated-, chitosan-(CS)- or chitosan-glutathione conjugate- (CS-GSH)-coated liposomes to protect the neurotransmitter Dopamine (DA) from the autoxidation reaction in neutral/alkaline conditions. This may be of interest in the development of nanotechnology-based approaches to improve Parkinson's disease treatment because decreased ROS production and reduced DA associated neurotoxicity are expected. For the mentioned purposes, DA-loaded vesicles were prepared by the Dried Reconstituted Vesicles (DRV) method, and were subsequently coated using solutions of polycations. As for the mean diameters of liposomes so prepared, the CS-GSH coated liposomes showed a significant decrease in size compared to the corresponding non-coated and CS-coated vesicles. The surface charge of DA-loaded non-coated liposomes was -10.8 mV, whereas the CS or CS-GSH coated vesicles showed a slightly positive ζ-potential. The capability of the herein studied vesicles to prevent DA autoxidation was evaluated by visual inspection, monitoring DA/lipid ratio as such and under stressed conditions. The results suggest that liposome formulations partially protect the neurotransmitter from the autoxidation reaction. In particular, the CS-GSH coated liposomes were more stable than the corresponding CS-coated and non-coated ones against the oxidative damage and were found to deliver the neurotransmitter in a sustained manner. Probably, this is due to the localization of the neurotransmitter in the core of the vesicles as indicated by XPS which confirmed the absence of the neurotransmitter on the surface of these vesicles. Copyright © 2018 Elsevier B.V. All rights reserved.

  20. Redefining Perineural Invasion: Integration of Biology With Clinical Outcome.

    PubMed

    Schmitd, Ligia B; Beesley, Lauren J; Russo, Nickole; Bellile, Emily L; Inglehart, Ronald C; Liu, Min; Romanowicz, Genevieve; Wolf, Gregory T; Taylor, Jeremy M G; D'Silva, Nisha J

    2018-05-22

    A diagnosis of perineural invasion (PNI), defined as cancer within or surrounding at least 33% of the nerve, leads to selection of aggressive treatment in squamous cell carcinoma (SCC). Recent mechanistic studies show that cancer and nerves interact prior to physical contact. The purpose of this study was to explore cancer-nerve interactions relative to clinical outcome. Biopsy specimens from 71 patients with oral cavity SCC were stained with hematoxylin and eosin and immunohistochemical (IHC; cytokeratin, S100, GAP43, Tuj1) stains. Using current criteria, PNI detection was increased with IHC. Overall survival (OS) tended to be poor for patients with PNI (P = .098). OS was significantly lower for patients with minimum tumor-nerve distance smaller than 5 μm (P = .011). The estimated relative death rate decreased as the nerve-tumor distance increased; there was a gradual drop off in death rate from distance equal to zero that stabilized around 500 μm. In PNI-negative patients, nerve diameter was significantly related to OS (HR 2.88, 95%CI[1.11,7.49]). Among PNI-negative nerves, larger nerve-tumor distance and smaller nerve diameter were significantly related to better OS, even when adjusting for T-stage and age (HR 0.82, 95% CI[0.72,0.92]; HR 1.27, 95% CI[1.00,1.62], respectively). GAP43, a marker for neuronal outgrowth, stained less than Tuj1 in nerves at greater distances from tumor (OR 0.76, 95% CI[0.73,0.79]); more GAP43 staining was associated with PNI. Findings from a small group of patients suggest that nerve parameters other than presence of PNI can influence outcome and that current criteria of PNI need to be re-evaluated to integrate recent biological discoveries. Copyright © 2018 The Authors. Published by Elsevier Inc. All rights reserved.

  1. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle.

    PubMed

    Kim, Hyung Jin; Seo, Yeong Ho; Kim, Byeong Hee

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3-5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3-5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more.

  2. New intraocular pressure measurement method using reflected pneumatic pressure from cornea deformed by air puff of ring-type nozzle

    PubMed Central

    Kim, Hyung Jin; Seo, Yeong Ho

    2017-01-01

    In this study, a non-contact type intraocular pressure (IOP) measuring system using reflected pneumatic pressure is proposed to overcome the disadvantages of existing measurement systems. A ring-type nozzle, a key component in the proposed system, is designed via computational fluid analysis. It predicts the reflected pneumatic pressure based on the nozzle exit angle and inner and outer diameters of the nozzle, which are 30°, 7 mm, and 9 mm, respectively. Performance evaluation is conducted using artificial eyes fabricated using polydimethylsiloxane with the specifications of human eyes. The IOP of the fabricated artificial eyes is adjusted to 10, 30, and 50 mm Hg, and the reflected pneumatic pressure is measured as a function of the distance between the ring-type nozzle and artificial eye. The measured reflected pneumatic pressure is high when the measurement distance is short and eye pressure is low. The cornea of an artificial eye is significantly deformed at a low IOP, and the applied pneumatic pressure is more concentrated in front of the ring-type nozzle because of the deformed cornea. Thus, the reflected pneumatic pressure at a low IOP has more inflows into the pressure sensor inserted inside the nozzle. The sensitivity of the output based on the IOP at measurement distances between 3–5 mm is -0.0027, -0.0022, -0.0018, -0.0015, and -0.0012. Sensitivity decreases as the measurement distance increases. In addition, the reflected pneumatic pressure owing to the misalignment at the measurement distances of 3–5 mm is not affected within a range of 0.5 mm. Therefore, the measurement range is acceptable up to a 1 mm diameter from the center of an artificial eye. However, the accuracy gradually decreases as the reflected pneumatic pressure from a misalignment of 1 mm or more decreases by 26% or more. PMID:29216189

  3. Cognitive control predicted by color vision, and vice versa.

    PubMed

    Colzato, Lorenza S; Sellaro, Roberta; Hulka, Lea M; Quednow, Boris B; Hommel, Bernhard

    2014-09-01

    One of the most important functions of cognitive control is to continuously adapt cognitive processes to changing and often conflicting demands of the environment. Dopamine (DA) has been suggested to play a key role in the signaling and resolution of such response conflict. Given that DA is found in high concentration in the retina, color vision discrimination has been suggested as an index of DA functioning and in particular blue-yellow color vision impairment (CVI) has been used to indicate a central hypodopaminergic state. We used color discrimination (indexed by the total color distance score; TCDS) to predict individual differences in the cognitive control of response conflict, as reflected by conflict-resolution efficiency in an auditory Simon task. As expected, participants showing better color discrimination were more efficient in resolving response conflict. Interestingly, participants showing a blue-yellow CVI were associated with less efficiency in handling response conflict. Our findings indicate that color vision discrimination might represent a promising predictor of cognitive controlability in healthy individuals. Copyright © 2014 Elsevier Ltd. All rights reserved.

  4. Effect of Dimension and Shape of Magnet on the Performance AC Generator with Translation Motion

    NASA Astrophysics Data System (ADS)

    Indriani, A.; Dimas, S.; Hendra

    2018-02-01

    The development of power plants using the renewable energy sources is very rapid. Renewable energy sources used solar energy, wind energy, ocean wave energy and other energy. All of these renewable energy sources require a processing device or a change of motion system to become electrical energy. One processing device is a generator which have work principle of converting motion (mechanical) energy into electrical energy with rotary shaft, blade and other motion components. Generator consists of several types of rotation motion and linear motion (translational). The generator have components such as rotor, stator and anchor. In the rotor and stator having magnet and winding coil as an electric generating part of the electric motion force. Working principle of AC generator with linear motion (translation) also apply the principle of Faraday that is using magnetic induction which change iron magnet to produce magnetic flux. Magnetic flux is captured by the stator to be converted into electrical energy. Linear motion generators consist of linear induction machine, wound synchronous machine field, and permanent magnet synchronous [1]. Performance of synchronous generator of translation motion is influenced by magnet type, magnetic shape, coil winding, magnetic and coil spacing and others. In this paper focus on the neodymium magnet with varying shapes, number of coil windings and gap of magnetic distances. This generator work by using pneumatic mechanism (PLTGL) for power plants system. Result testing of performance AC generator translation motion obtained that maximum voltage, current and power are 63 Volt for diameter winding coil 0.15 mm, number of winding coil 13000 and distance of magnet 20 mm. For effect shape of magnet, maximum voltage happen on rectangle magnet 30x20x5 mm with 4.64 Volt. Voltage and power on effect of diameter winding coil is 14.63 V and 17.82 W at the diameter winding coil 0.7 and number of winding coil is 1260 with the distance of magnet 25 mm.

  5. Predicting through-focus visual acuity with the eye's natural aberrations.

    PubMed

    Kingston, Amanda C; Cox, Ian G

    2013-10-01

    To develop a predictive optical modeling process that utilizes individual computer eye models along with a novel through-focus image quality metric. Individual eye models were implemented in optical design software (Zemax, Bellevue, WA) based on evaluation of ocular aberrations, pupil diameter, visual acuity, and accommodative response of 90 subjects (180 eyes; 24-63 years of age). Monocular high-contrast minimum angle of resolution (logMAR) acuity was assessed at 6 m, 2 m, 1 m, 67 cm, 50 cm, 40 cm, 33 cm, 28 cm, and 25 cm. While the subject fixated on the lowest readable line of acuity, total ocular aberrations and pupil diameter were measured three times each using the Complete Ophthalmic Analysis System (COAS HD VR) at each distance. A subset of 64 mature presbyopic eyes was used to predict the clinical logMAR acuity performance of five novel multifocal contact lens designs. To validate predictability of the design process, designs were manufactured and tested clinically on a population of 24 mature presbyopes (having at least +1.50 D spectacle add at 40 cm). Seven object distances were used in the validation study (6 m, 2 m, 1 m, 67 cm, 50 cm, 40 cm, and 25 cm) to measure monocular high-contrast logMAR acuity. Baseline clinical through-focus logMAR was shown to correlate highly (R² = 0.85) with predicted logMAR from individual eye models. At all object distances, each of the five multifocal lenses showed less than one line difference, on average, between predicted and clinical normalized logMAR acuity. Correlation showed R² between 0.90 and 0.97 for all multifocal designs. Computer-based models that account for patient's aberrations, pupil diameter changes, and accommodative amplitude can be used to predict the performance of contact lens designs. With this high correlation (R² ≥ 0.90) and high level of predictability, more design options can be explored in the computer to optimize performance before a lens is manufactured and tested clinically.

  6. Morphological parameters associated with ruptured posterior communicating aneurysms.

    PubMed

    Ho, Allen; Lin, Ning; Charoenvimolphan, Nareerat; Stanley, Mary; Frerichs, Kai U; Day, Arthur L; Du, Rose

    2014-01-01

    The rupture risk of unruptured intracranial aneurysms is known to be dependent on the size of the aneurysm. However, the association of morphological characteristics with ruptured aneurysms has not been established in a systematic and location specific manner for the most common aneurysm locations. We evaluated posterior communicating artery (PCoA) aneurysms for morphological parameters associated with aneurysm rupture in that location. CT angiograms were evaluated to generate 3-D models of the aneurysms and surrounding vasculature. Univariate and multivariate analyses were performed to evaluate morphological parameters including aneurysm volume, aspect ratio, size ratio, distance to ICA bifurcation, aneurysm angle, vessel angles, flow angles, and vessel-to-vessel angles. From 2005-2012, 148 PCoA aneurysms were treated in a single institution. Preoperative CTAs from 63 patients (40 ruptured, 23 unruptured) were available and analyzed. Multivariate logistic regression revealed that smaller volume (p = 0.011), larger aneurysm neck diameter (0.048), and shorter ICA bifurcation to aneurysm distance (p = 0.005) were the most strongly associated with aneurysm rupture after adjusting for all other clinical and morphological variables. Multivariate subgroup analysis for patients with visualized PCoA demonstrated that larger neck diameter (p = 0.018) and shorter ICA bifurcation to aneurysm distance (p = 0.011) were significantly associated with rupture. Intracerebral hemorrhage was associated with smaller volume, larger maximum height, and smaller aneurysm angle, in addition to lateral projection, male sex, and lack of hypertension. We found that shorter ICA bifurcation to aneurysm distance is significantly associated with PCoA aneurysm rupture. This is a new physically intuitive parameter that can be measured easily and therefore be readily applied in clinical practice to aid in the evaluation of patients with PCoA aneurysms.

  7. Morphological Parameters Associated with Ruptured Posterior Communicating Aneurysms

    PubMed Central

    Ho, Allen; Lin, Ning; Charoenvimolphan, Nareerat; Stanley, Mary; Frerichs, Kai U.; Day, Arthur L.; Du, Rose

    2014-01-01

    The rupture risk of unruptured intracranial aneurysms is known to be dependent on the size of the aneurysm. However, the association of morphological characteristics with ruptured aneurysms has not been established in a systematic and location specific manner for the most common aneurysm locations. We evaluated posterior communicating artery (PCoA) aneurysms for morphological parameters associated with aneurysm rupture in that location. CT angiograms were evaluated to generate 3-D models of the aneurysms and surrounding vasculature. Univariate and multivariate analyses were performed to evaluate morphological parameters including aneurysm volume, aspect ratio, size ratio, distance to ICA bifurcation, aneurysm angle, vessel angles, flow angles, and vessel-to-vessel angles. From 2005–2012, 148 PCoA aneurysms were treated in a single institution. Preoperative CTAs from 63 patients (40 ruptured, 23 unruptured) were available and analyzed. Multivariate logistic regression revealed that smaller volume (p = 0.011), larger aneurysm neck diameter (0.048), and shorter ICA bifurcation to aneurysm distance (p = 0.005) were the most strongly associated with aneurysm rupture after adjusting for all other clinical and morphological variables. Multivariate subgroup analysis for patients with visualized PCoA demonstrated that larger neck diameter (p = 0.018) and shorter ICA bifurcation to aneurysm distance (p = 0.011) were significantly associated with rupture. Intracerebral hemorrhage was associated with smaller volume, larger maximum height, and smaller aneurysm angle, in addition to lateral projection, male sex, and lack of hypertension. We found that shorter ICA bifurcation to aneurysm distance is significantly associated with PCoA aneurysm rupture. This is a new physically intuitive parameter that can be measured easily and therefore be readily applied in clinical practice to aid in the evaluation of patients with PCoA aneurysms. PMID:24733151

  8. Design of ocular for optical sight with long exit pupil distance

    NASA Astrophysics Data System (ADS)

    Zhu, Zhongyao; Li, Yuyao; Tian, Ailing

    2017-02-01

    In order to solve the injury of optical sight to shooters, which is produced by recoil for using artillery or firearms, and the usage problems of shooters' eye mask, headband and gas mask, the ocular with long exit pupil distance has been designed based on optical sighting system. The optical properties and aberration characteristics of ocular with long exit pupil distance has been analyzed, the structural style with positive-positive-negative three lens groups has been put forward. According to the aberration theory and the isoplanatic image formation principle, the focal power assignment expression has been deduced by adopting analytical method. By using of optical design software ZEMAX, the ocular with long exit pupil distance has been designed, the focal length of system is 20mm, the exit pupil diameter is 4mm, the field angle is 40°, the distance of exit pupil is 41mm, and the relative eye relief is greater than 2. The design results show if this method has been adopted, the transfer functions of each field are all greater than 0.15 when the ocular with long exit pupil distance locates on 45lp/mm, which can meet the use requirements of visual optical instruments.

  9. Cryo-transmission electron tomography of native casein micelles from bovine milk.

    PubMed

    Trejo, R; Dokland, T; Jurat-Fuentes, J; Harte, F

    2011-12-01

    Caseins are the principal protein components in milk and an important ingredient in the food industry. In liquid milk, caseins are found as micelles of casein proteins and colloidal calcium nanoclusters. Casein micelles were isolated from raw skim milk by size exclusion chromatography and suspended in milk protein-free serum produced by ultrafiltration (molecular weight cut-off of 3 kDa) of raw skim milk. The micelles were imaged by cryo-electron microscopy and subjected to tomographic reconstruction methods to visualize the 3-dimensional and internal organization of native casein micelles. This provided new insights into the internal architecture of the casein micelle that had not been apparent from prior cryo-transmission electron microscopy studies. This analysis demonstrated the presence of water-filled cavities (∼20 to 30 nm in diameter), channels (diameter greater than ∼5 nm), and several hundred high-density nanoclusters (6 to 12 nm in diameter) within the interior of the micelles. No spherical protein submicellar structures were observed. Copyright © 2011 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  10. Vertically aligned double wall carbon nanotube arrays adsorbent for pure and mixture adsorption of H2S, ethylbenzene and carbon monoxide, grand canonical Monte Carlo simulation.

    PubMed

    Tasharrofi, Saeideh; Taghdisian, Hossein; Golchoobi, Abdollah

    2018-05-01

    In this study, pure and ternary adsorption of hydrogen sulfide (H 2 S), ethylbenzene (EB), and carbon monoxide (CO) on different arrays of zigzag double wall carbon nanotube was investigated using grand canonical Monte Carlo simulations. The internal diameters of nanotube were fixed at 2r = 50.17 Å while nanotube wall distances were different values from d = 0 Å to d = 150 Å. Pure simulation results indicated that adsorption quantity of H 2 S and EB in low pressure ranges of P = 1.9 bar to P = 3.1 bar was at least 100% more than CO adsorption quantities. At high pressure ranges of P = 23.1 bar to P = 38.2 bar H 2 S adsorption was greater than EB and CO by about 200 molecules per unit cell (UC) at low nanotube distances. This was related to smaller kinetic diameter and greater dipole moment of H 2 S compared to EB and CO. At higher nanotube distance the effect of size however disappears and all three gases approach to adsorption quantity of about 800 molecules/UC. Graphical representation of adsorption areas showed that H 2 S and CO form multilayer adsorption around nanotube inner and outer walls while EB fill the whole space uniformly without any congestion around the walls. Ternary adsorption results EB/CO and H 2 S/CO selectivity are greater than EB/H 2 S selectivity. In addition, at smaller nanotube distances H 2 S/CO selectivity is generally higher than EB/CO selectivity, which at higher nanotube distance the order becomes revers suggesting that size dependent effects on adsorption vanishes. Isosteric heat of adsorption shows that the order of EB > H 2 S > CO suggesting that ethylbenzene interaction with nanotube arrays was strongest. Although H 2 S has a greater dipole moment and smaller molecular dimension, EB adsorption at higher nanotube distance is greater than H 2 S by at least 50% probably because EB is less volatile. Copyright © 2018 Elsevier Inc. All rights reserved.

  11. SU-G-TeP3-04: Evaluation of the Dose Enhancement with Gold Nanoparticle in Microdosimetry Level Using the Geant4-DNA Toolkit

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    He, C; Chow, J

    Purpose: This study investigated the dose enhancement effect of using gold nanoparticles (GNP) as radiation sensitizers radiated by different photon beam energies. Microdosimetry of photon-irradiated GNP was determined by the Geant4-DNA process in the DNA scale. Methods: Monte Carlo simulation was conducted using the Geant4 toolkit (ver. 10.2). A GNP with different sizes (30, 50, and 100nm diameter sphere) and a DNA were placed in a water cube (1µm{sup 3}). The GNP was irradiated by photon beams with different energies (50, 100, and 150keV) and produced secondary electrons to increase the dose to the DNA. Energy depositions were calculated formore » both with and without GNP and to investigate the dose enhancement effect at the DNA. The distance between the GNP and DNA was varied to optimize the best GNP position to the DNA. The photon beam source was set to 200nm from the GNP in each simulation. Results: It is found that GNP had a dose enhancement effect on kV photon radiations. For Monte Carlo results on different GNP sizes, distances between the GNP and DNA, and photon beam energies, enhancement ratio was found increasing as GNP size increased. The distance between the GNP and DNA affected the result that as distance increased while the dose enhancement ratio decreased. However, the effect of changing distance was not as significant as varying the GNP size. In addition, increasing the photon beam energy also increased the dose enhancement ratio. The largest dose enhancement ratio was found to be 3.5, when the GNP (100nm diameter) irradiated by the 150keV photon beam was set to 80nm from the DNA. Conclusion: Dose enhancement was determined in the DNA with GNP in the microdosimetry scale. It is concluded that the dose enhancement varied with the photon beam energy, GNP size and distance between the GNP and DNA.« less

  12. Computer-assisted study of the axial orientation and distances between renovisceral arteries ostia.

    PubMed

    Lawton, James; Touma, Joseph; Sénémaud, Jean; de Boissieu, Paul; Brossier, Julien; Kobeiter, Hicham; Desgranges, Pascal

    2017-02-01

    Endovascular navigation in aortic, renal and visceral procedures are based on precise knowledge of arterial anatomy. Our aim was to define the anatomical localization of the ostia of renovisceral arteries and their distribution to establish anatomical landmarks for endovascular catheterization. Computer-assisted measurements performed on 55 CT scans and patients features (age, sex, aortic diameter) were analyzed. p values <0.05 were considered statistically significant. The mean axial angulation of CeT and the SMA origin was 21.8° ± 10.1° and 9.9° ± 10.5°, respectively. The ostia were located on the left anterior edge of the aorta in 96 % of cases for the CeT and 73 % for the SMA. CeT and SMA angles followed Gaussian distribution. Left renal artery (LRA) rose at 96° ± 15° and in 67 % of cases on the left posterior edge. The right renal artery (RRA) rose at -62° ± 16.5° and in 98 % of cases on the right anterior edge of the aorta. RRA angle measurements and cranio-caudal RRA-LRA distance measurements did not follow Gaussian distribution. The mean distances between the CeT and the SMA, LRA, and RRA were 16.7 ± 5.0, 30.7 ± 7.9 and 30.5 ± 7.7 mm, respectively. CeT-SMA distance showed correlation with age and aortic diameter (p = 0.03). CeT-LRA distance showed correlation with age (p = 0.04). The mean distance between the renal ostia was 3.75 ± 0.21 mm. The RRA ostium was higher than the LRA ostium in 52 % of cases. RRA and LRA origins were located at the same level in 7 % of cases. Our results illustrate aortic elongation with ageing and high anatomical variability of renal arteries. Our findings are complementary to anatomical features previously published and might contribute to enhance endovascular procedures safety and efficacy for vascular surgeons and interventional radiologists.

  13. Fluorescence Manipulation by Gold Nanoparticles: From Complete Quenching to Extensive Enhancement

    PubMed Central

    2011-01-01

    Background When a fluorophore is placed in the vicinity of a metal nanoparticle possessing a strong plasmon field, its fluorescence emission may change extensively. Our study is to better understand this phenomenon and predict the extent of quenching and/or enhancement of fluorescence, to beneficially utilize it in molecular sensing/imaging. Results Plasmon field intensities on/around gold nanoparticles (GNPs) with various diameters were theoretically computed with respect to the distance from the GNP surface. The field intensity decreased rapidly with the distance from the surface and the rate of decrease was greater for the particle with a smaller diameter. Using the plasmon field strength obtained, the level of fluorescence alternation by the field was theoretically estimated. For experimental studies, 10 nm GNPs were coated with polymer layer(s) of known thicknesses. Cypate, a near infrared fluorophore, was placed on the outermost layer of the polymer coated GNPs, artificially separated from the GNP at known distances, and its fluorescence levels were observed. The fluorescence of Cypate on the particle surface was quenched almost completely and, at approximately 5 nm from the surface, it was enhanced ~17 times. The level decreased thereafter. Theoretically computed fluorescence levels of the Cypate placed at various distances from a 10 nm GNP were compared with the experimental data. The trend of the resulting fluorescence was similar. The experimental results, however, showed greater enhancement than the theoretical estimates, in general. The distance from the GNP surface that showed the maximum enhancement in the experiment was greater than the one theoretically predicted, probably due to the difference in the two systems. Conclusions Factors affecting the fluorescence of a fluorophore placed near a GNP are the GNP size, coating material on GNP, wavelengths of the incident light and emitted light and intrinsic quantum yield of the fluorophore. Experimentally, we were able to quench and enhance the fluorescence of Cypate, by changing the distance between the fluorophore and GNP. This ability of artificially controlling fluorescence can be beneficially used in developing contrast agents for highly sensitive and specific optical sensing and imaging. PMID:21569249

  14. Fast-Acting Valve

    NASA Technical Reports Server (NTRS)

    Wojciechowski, Bogdan V. (Inventor); Pegg, Robert J. (Inventor)

    2003-01-01

    A fast-acting valve includes an annular valve seat that defines an annular valve orifice between the edges of the annular valve seat, an annular valve plug sized to cover the valve orifice when the valve is closed, and a valve-plug holder for moving the annular valve plug on and off the annular valve seat. The use of an annular orifice reduces the characteristic distance between the edges of the valve seat. Rather than this distance being equal to the diameter of the orifice, as it is for a conventional circular orifice, the characteristic distance equals the distance between the inner and outer radii (for a circular annulus). The reduced characteristic distance greatly reduces the gap required between the annular valve plug and the annular valve seat for the valve to be fully open, thereby greatly reducing the required stroke and corresponding speed and acceleration of the annular valve plug. The use of a valve-plug holder that is under independent control to move the annular valve plug between its open and closed positions is important for achieving controllable fast operation of the valve.

  15. Improving single-molecule FRET measurements by confining molecules in nanopipettes

    NASA Astrophysics Data System (ADS)

    Vogelsang, J.; Doose, S.; Sauer, M.; Tinnefeld, P.

    2007-07-01

    In recent years Fluorescence Resonance Energy Transfer (FRET) has been widely used to determine distances, observe distance dynamics, and monitor molecular binding at the single-molecule level. A basic constraint of single-molecule FRET studies is the limited distance resolution owing to low photon statistics. We demonstrate that by confining molecules in nanopipettes (50-100 nm diameter) smFRET can be measured with improved photon statistics reducing the width of FRET proximity ratio distributions (PRD). This increase in distance resolution makes it possible to reveal subpopulations and dynamics in biomolecular complexes. Our data indicate that the width of PRD is not only determined by photon statistics (shot noise) and distance distributions between the chromophores but that photoinduced dark states of the acceptor also contribute to the PRD width. Furthermore, acceptor dark states such as triplet states influence the accuracy of determined mean FRET values. In this context, we present a strategy for the correction of the shift of the mean PR that is related to triplet induced blinking of the acceptor using reference FCS measurements.

  16. Noise characteristics of the O-1 airplane and some approaches to noise reduction

    NASA Technical Reports Server (NTRS)

    Connor, A. B.; Hilton, D. A.; Copeland, W. L.; Clark, L. R.

    1975-01-01

    A brief study of the O-1A airplane to determine possible means for reducing the aircraft aural detection distance was conducted. This effort involved measuring the noise signature of the basic airplane, devising methods to attenuate the noise, and then estimating the effect of several selected modifications on the aural detection distance of the aircraft. A relatively simple modification utilizing a 6.5 ft diameter, six-blade propeller and including a muffler having a volume of 0.725 cu ft is indicated to reduce the aural detection distance of the O-1 aircraft from about 6 miles at an altitude of 1,000 ft and 2 to 3 miles at an altitude of 300 ft to approximately half these values. The flyover noise data suggest that routing the exhaust stacks up and over the wing would provide immediate noise reduction of about 5 dB with an attendant reduction in detection distance. Furthermore, all these studies confirm the work of other investigators that the 1/3 octave band (center frequency=125 cps) is the most critical in reducing aural detection distance.

  17. Why do complex impact craters have elevated crater rims?

    NASA Astrophysics Data System (ADS)

    Kenkmann, Thomas; Sturm, Sebastian; Krueger, Tim

    2014-05-01

    Most of the complex impact craters on the Moon and on Mars have elevated crater rims like their simple counterparts. The raised rim of simple craters is the result of (i) the deposition of a coherent proximal ejecta blanket at the edge of the transient cavity (overturned flap) and (ii) a structural uplift of the pre-impact surface near the transient cavity rim during the excavation stage of cratering [1]. The latter occurs either by plastic thickening or localized buckling of target rocks, as well as by the emplacement of interthrust wedges [2] or by the injection of dike material. Ejecta and the structural uplift contribute equally to the total elevation of simple crater rims. The cause of elevated crater rims of large complex craters [3] is less obvious, but still, the rim height scales with the final crater diameter. Depending on crater size, gravity, and target rheology, the final crater rim of complex craters can be situated up to 1.5-2.0 transient crater radii distance from the crater center. Here the thickness of the ejecta blanket is only a fraction of that occurring at the rim of simple craters, e.g. [4], and thus cannot account for a strong elevation. Likewise, plastic thickening including dike injection of the underlying target may not play a significant role at this distance any more. We started to systematically investigate the structural uplift and ejecta thickness along the rim of complex impact craters to understand the cause of their elevation. Our studies of two lunar craters (Bessel, 16 km diameter and Euler, 28 km diameter) [5] and one unnamed complex martian crater (16 km diameter) [6] showed that the structural uplift at the final crater rim makes 56-67% of the total rim elevation while the ejecta thickness contributes 33-44%. Thus with increasing distance from the transient cavity rim, the structural uplift seems to dominate. As dike injection and plastic thickening are unlikely at such a distance from the transient cavity, we propose that reverse faulting induced by radially outward directed maximum stresses during the excavation flow may be responsible for the elevation of complex crater rims. This hypothesis is tested at terrestrial craters whose apparent crater rims are often confined by circumferential faults [7]. References:[1] Shoemaker, E. M. (1963) The Solar System, 4, 301-336. [2] Poelchau M.H. et al. (2009), JGR, 114, E01006. [3] Settle, M., and Head, J.W., (1977), Icarus, 31, 123. [4] McGetchin, T. R., et al., (1973), EPSL, 20, 226.[5] Krüger T. et al. (2014), LPSC 45, #1834. [6] Sturm, S. et al. (2014), LPSC 45, 1801. [7] Turtle, E. et al. (2005), GSA-SP. 384, 1.

  18. Analysis of variance to assess statistical significance of Laplacian estimation accuracy improvement due to novel variable inter-ring distances concentric ring electrodes.

    PubMed

    Makeyev, Oleksandr; Joe, Cody; Lee, Colin; Besio, Walter G

    2017-07-01

    Concentric ring electrodes have shown promise in non-invasive electrophysiological measurement demonstrating their superiority to conventional disc electrodes, in particular, in accuracy of Laplacian estimation. Recently, we have proposed novel variable inter-ring distances concentric ring electrodes. Analytic and finite element method modeling results for linearly increasing distances electrode configurations suggested they may decrease the truncation error resulting in more accurate Laplacian estimates compared to currently used constant inter-ring distances configurations. This study assesses statistical significance of Laplacian estimation accuracy improvement due to novel variable inter-ring distances concentric ring electrodes. Full factorial design of analysis of variance was used with one categorical and two numerical factors: the inter-ring distances, the electrode diameter, and the number of concentric rings in the electrode. The response variables were the Relative Error and the Maximum Error of Laplacian estimation computed using a finite element method model for each of the combinations of levels of three factors. Effects of the main factors and their interactions on Relative Error and Maximum Error were assessed and the obtained results suggest that all three factors have statistically significant effects in the model confirming the potential of using inter-ring distances as a means of improving accuracy of Laplacian estimation.

  19. Poly(glycidyl ether)-Based Monolayers on Gold Surfaces: Control of Grafting Density and Chain Conformation by Grafting Procedure, Surface Anchor, and Molecular Weight.

    PubMed

    Heinen, Silke; Weinhart, Marie

    2017-03-07

    For a meaningful correlation of surface coatings with their respective biological response reproducible coating procedures, well-defined surface coatings, and thorough surface characterization with respect to layer thickness and grafting density are indispensable. The same applies to polymeric monolayer coatings which are intended to be used for, e.g., fundamental studies on the volume phase transition of surface end-tethered thermoresponsive polymer chains. Planar gold surfaces are frequently used as model substrates, since they allow a variety of straightforward surface characterization methods. Herein we present reproducible grafting-to procedures performed with thermoresponsive poly(glycidyl ether) copolymers composed of glycidyl methyl ether (GME) and ethyl glycidyl ether (EGE). The copolymers feature different molecular weights (2 kDa, 9 kDa, 24 kDa) and are equipped with varying sulfur-containing anchor groups in order to achieve adjustable grafting densities on gold surfaces and hence control the tethered polymers' chain conformation. We determined "wet" and "dry" thicknesses of these coatings by QCM-D and ellipsometry measurements and deduced anchor distances and degrees of chain overlap of the polymer chains assembled on gold. Grafting under cloud point conditions allowed for higher degrees of chain overlap compared to grafting from a good solvent like ethanol, independent of the used sulfur-containing anchor group for polymers with low (2 kDa) and medium (9 kDa) molecular weights. By contrast, the achieved grafting densities and thus chain overlaps of surface-tethered polymers with high (24 kDa) molecular weights were identical for both grafting methods. Monolayers prepared from an ethanolic solution of poly(glycidyl ether)s equipped with sterically demanding disulfide-containing anchors revealed the lowest degrees of chain overlap. The ratio of the radius of gyration to the anchor distance (2 R g /l) of the latter coating was found to be lower than 1.4, indicating that the assembly was rather in the mushroom-like than in the brush regime. Polymer chains with thiol-containing anchors of different alkyl chain lengths (C 11 SH vs C 4 SH) formed assemblies with comparable degrees of chain overlap with 2 R g /l values above 1.4 and are thus in the brush regime. Molecular weights influenced the achievable degree of chain overlap on the surface. Coatings prepared with the medium molecular weight polymer (9 kDa) resulted in the highest chain packing density. Control of grafting density and thus chain overlap in different regimes (brush vs mushroom) on planar gold substrates are attainable for monolayer coatings with poly(GME-ran-EGE) by adjusting the polymer's molecular weight and anchor group as well as the conditions for the grafting-to procedure.

  20. Experimental and Numerical Modeling of Aerosol Delivery for Preterm Infants

    PubMed Central

    Lopez-Arraiza, Alberto; Rey-Santano, Carmen; Mielgo, Victoria; Basterretxea, Francisco Jose; Sancho, Javier; Gomez-Solaetxe, Miguel Angel

    2018-01-01

    Respiratory distress syndrome (RDS) represents one of the major causes of mortality among preterm infants, and the best approach to treat it is an open research issue. The use of perfluorocarbons (PFC) along with non-invasive respiratory support techniques has proven the usefulness of PFC as a complementary substance to achieve a more homogeneous surfactant distribution. The aim of this work was to study the inhaled particles generated by means of an intracorporeal inhalation catheter, evaluating the size and mass distribution of different PFC aerosols. In this article, we discuss different experiments with the PFC perfluorodecalin (PFD) and FC75 with a driving pressure of 4–5 bar, evaluating properties such as the aerodynamic diameter (Da), since its value is directly linked to particle deposition in the lung. Furthermore, we develop a numerical model with computational fluid dynamics (CFD) techniques. The computational results showed an accurate prediction of the airflow axial velocity at different downstream positions when compared with the data gathered from the real experiments. The numerical validation of the cumulative mass distribution for PFD particles also confirmed a closer match with the experimental data measured at the optimal distance of 60 mm from the catheter tip. In the case of FC75, the cumulative mass fraction for particles above 10 µm was considerable higher with a driving pressure of 5 bar. These numerical models could be a helpful tool to assist parametric studies of new non-invasive devices for the treatment of RDS in preterm infants. PMID:29495619

  1. Chirality correlation in double-wall carbon nanotubes as studied by electron diffraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hirahara, Kaori; Bandow, Shunji; Kociak, Mathieu

    2006-05-15

    Structural correlation between two adjacent graphitic layers in double-wall carbon nanotubes (DWNTs) was systematically examined by using electron diffraction. Chiral angles and tube diameters were carefully measured, and the chiral indices of individual DWNTs were accurately determined. As a result, it was found that the interlayer distances of DWNTs were widely distributed in the range between 0.34 and 0.38 nm. Chiralities of the inner and outer tubes tended to be distributed at higher chiral angles, approaching 30 deg., for the tubes with diameter D<{approx}3 nm. On the other hand, for the tubes with D>{approx}3 nm, the chiral angles were widelymore » distributed, covering the chiral map entirely. Therefore, we consider that tubes with small diameters have a tendency to form armchair type. Correlation of chiralities between the inner and outer tubes was found to be random.« less

  2. Friction loss in straight pipes of unplasticized polyvinyl chloride.

    PubMed

    Iwasaki, T; Ojima, J

    1996-01-01

    In order to design proper ductwork for a local exhaust system, airflow characteristics were investigated in straight pipes of unplasticized polyvinyl chloride (PVC). A linear decrease in static pressure was observed downstream at points from the opening of the VU pipes (JIS K 6741) located at distances greater than 10 times the pipe diameter, for velocities ranging between 10.18-36.91 m/s. Roughness inside pipes with small diameters was found to be 0.0042-0.0056 mm and the friction factor was calculated on the basis of Colebrook's equation for an airflow transition zone. An extended friction chart was then constructed on the basis of the roughness value and the friction factor. This chart can be applied when designing a local exhaust system with the ducts of diameters ranging from 40 to 900 mm. The friction loss of the PVC pipe was found to be approximately 2/3 of that of a galvanized steel pipe.

  3. Influence of Angiotensin-Converting-Enzyme Gene Polymorphism on Echocardiographic Data of Patients with Ischemic Heart Failure.

    PubMed

    Duque, Gustavo Salgado; Silva, Dayse Aparecida da; Albuquerque, Felipe Neves de; Schneider, Roberta Siuffo; Gimenez, Alinne; Pozzan, Roberto; Rocha, Ricardo Mourilhe; Albuquerque, Denilson Campos de

    2016-11-01

    Association between angiotensin-converting-enzyme (ACE) gene polymorphisms and different clinical and echocardiographic outcomes has been described in patients with heart failure (HF) and coronary artery disease. Studying the genetic profile of the local population with both diseases is necessary to assess the occurrence of that association. To assess the frequency of ACE gene polymorphisms in patients with ischemic HF in a Rio de Janeiro population, as well as its association with echocardiographic findings. Genetic assessment of I/D ACE polymorphism in association with clinical, laboratory and echocardiographic analysis of 99 patients. The allele frequency was: 53 I alleles, and 145 D alleles. Genotype frequencies were: 49.5% DD; 47.48% DI; 3.02% II. Drug treatment was optimized: 98% on beta-blockers, and 84.8% on ACE inhibitors or angiotensin-receptor blocker. Echocardiographic findings: difference between left ventricular diastolic diameters (ΔLVDD) during follow-up: 2.98±8.94 (DD) vs. 0.68±8.12 (DI) vs. -11.0±7.00 (II), p=0.018; worsening during follow-up of the LV systolic diameter (LVSD): 65.3% DD vs. 19.0% DI vs. 0.0% II, p=0.01; of the LV diastolic diameter (LVDD): 65.3% DD vs. 46.8% DI vs. 0.0% II, p=0.03; and of the LV ejection fraction (LVEF): 67.3% DD vs. 40.4% DI vs. 33.3% II, p=0.024. Correlated with D allele: ΔLVEF, ΔLVSD, ΔLVDD. More DD genotype patients had worsening of the LVEF, LVSD and LVDD, followed by DI genotype patients, while II genotype patients had the best outcome. The same pattern was observed for ΔLVDD. Associação entre polimorfismos genéticos da enzima conversora da angiotensina (ECA) e diferentes evoluções clínicas e ecocardiográficas foi descrita em pacientes com insuficiência cardíaca (IC) e coronariopatia. O estudo do perfil genético da população local com as duas doenças torna-se necessário para verificar a ocorrência dessa associação. Avaliar a frequência dos polimorfismos genéticos da ECA em pacientes com IC de etiologia isquêmica de uma população do Rio de Janeiro e sua associação com achados ecocardiográficos. Avaliação genética do polimorfismo I/D da ECA associada a análise de dados clínicos, laboratoriais e ecocardiográficos de 99 pacientes. Foram encontrados 53 alelos I, 145 alelos D, quanto aos genótipos da ECA: 49,5% DD, 47,48% DI, 3,02% II. O tratamento medicamentoso foi otimizado com 98% usando betabloqueadores e 84,8%, IECA ou bloqueador do receptor de angiotensina. Achados ecocardiográficos: diferença entre os diâmetros diastólicos do ventrículo esquerdo (ΔVED): 2,98±8,94 (DD) vs. 0,68±8,12 (DI) vs. -11,0±7,00 (II), p=0,018; piora evolutiva do diâmetro sistólico do VE (VES): 65,3 % DD vs. 19,0 % DI vs. 0,0 % II, p=0,01; do diâmetro diastólico do VE (VED): 65,3 % DD vs. 46,8 % DI vs. 0,0 % II, p=0,03; e da fração de ejeção do VE (FEVE): 67,3 % DD vs. 40,4 % DI vs. 33,3 % II, p=0,024. Correlação com alelo D: ΔFEVE, ΔVES, ΔVED. Foram identificados mais pacientes com piora evolutiva da FEVE e dos diâmetros cavitários do VE no genótipo DD, seguido do DI, sendo o II o de melhor evolução. O mesmo padrão foi observado na ΔVED.

  4. The anatomy of the superficial external pudendal artery: a quantitative study.

    PubMed

    La Falce, Osvaldir Lanzoni; Ambrosio, João Dias; Souza, Romeu Rodrigues de

    2006-10-01

    The importance of the superficial external pudendal artery in cases of lower limb obstructive arteriopathies has been established, and a perfect knowledge of its anatomy is desirable for the creation of successful flaps involving it. However, little information is available on the morphometry of this artery. In this study, we conducted a quantitative investigation of the superficial external pudendal artery as the basis for skin grafts. Twenty-five right and left sides of the inguinal region of male cadavers were dissected. After retracting the skin at the inguinal region, the femoral vessels and the sapheno-femoral junction were exposed. The following aspects were then analyzed: 1) the presence of the superficial external pudendal artery, 2) the place of origin of the superficial external pudendal artery and the common trunk, 3) the duplication of the superficial external pudendal artery, 4) the distance from the superficial external pudendal artery or the common trunk to the inguinal ligament, and 5) the diameter of the superficial external pudendal artery. The results were the following: 1) superficial external pudendal arteries were found in 46 of 50 sides (92%); 2) they originated from the femoral artery in 45 cases and from the deep femoral artery in only 1 case; 3) the arteries were found duplicated in 21 cases (46%), as a common trunk in 11 cases (24%), and as a single artery in 14 cases (30%); 4) the distance from the superficial external pudendal artery to the inguinal ligament ranged from 0.8 cm to 8.5 cm; from the common trunk, it ranged from 3.5 cm to 6.7 cm; 5) the diameter of the superficial external pudendal artery ranged from 1.2 mm to 3.8 mm; and 6) the diameter of the common trunk ranged from 1.35 mm to 5.15 mm. The results show that the superficial external pudendal artery generally originates from the femoral artery. It was found as a common trunk, duplicated, or as a single artery. There was a great variability in both the diameter of the artery and the distance from the artery to the inguinal ligament. Most of the data showed no significant differences between the right and the left sides.

  5. Medical telerobotic systems: current status and future trends.

    PubMed

    Avgousti, Sotiris; Christoforou, Eftychios G; Panayides, Andreas S; Voskarides, Sotos; Novales, Cyril; Nouaille, Laurence; Pattichis, Constantinos S; Vieyres, Pierre

    2016-08-12

    Teleoperated medical robotic systems allow procedures such as surgeries, treatments, and diagnoses to be conducted across short or long distances while utilizing wired and/or wireless communication networks. This study presents a systematic review of the relevant literature between the years 2004 and 2015, focusing on medical teleoperated robotic systems which have witnessed tremendous growth over the examined period. A thorough insight of telerobotics systems discussing design concepts, enabling technologies (namely robotic manipulation, telecommunications, and vision systems), and potential applications in clinical practice is provided, while existing limitations and future trends are also highlighted. A representative paradigm of the short-distance case is the da Vinci Surgical System which is described in order to highlight relevant issues. The long-distance telerobotics concept is exemplified through a case study on diagnostic ultrasound scanning. Moreover, the present review provides a classification into short- and long-distance telerobotic systems, depending on the distance from which they are operated. Telerobotic systems are further categorized with respect to their application field. For the reviewed systems are also examined their engineering characteristics and the employed robotics technology. The current status of the field, its significance, the potential, as well as the challenges that lie ahead are thoroughly discussed.

  6. Evidence of new species for malaria vector Anopheles nuneztovari sensu lato in the Brazilian Amazon region.

    PubMed

    Scarpassa, Vera Margarete; Cunha-Machado, Antonio Saulo; Saraiva, José Ferreira

    2016-04-12

    Anopheles nuneztovari sensu lato comprises cryptic species in northern South America, and the Brazilian populations encompass distinct genetic lineages within the Brazilian Amazon region. This study investigated, based on two molecular markers, whether these lineages might actually deserve species status. Specimens were collected in five localities of the Brazilian Amazon, including Manaus, Careiro Castanho and Autazes, in the State of Amazonas; Tucuruí, in the State of Pará; and Abacate da Pedreira, in the State of Amapá, and analysed for the COI gene (Barcode region) and 12 microsatellite loci. Phylogenetic analyses were performed using the maximum likelihood (ML) approach. Intra and inter samples genetic diversity were estimated using population genetics analyses, and the genetic groups were identified by means of the ML, Bayesian and factorial correspondence analyses and the Bayesian analysis of population structure. The Barcode region dataset (N = 103) generated 27 haplotypes. The haplotype network suggested three lineages. The ML tree retrieved five monophyletic groups. Group I clustered all specimens from Manaus and Careiro Castanho, the majority of Autazes and a few from Abacate da Pedreira. Group II clustered most of the specimens from Abacate da Pedreira and a few from Autazes and Tucuruí. Group III clustered only specimens from Tucuruí (lineage III), strongly supported (97 %). Groups IV and V clustered specimens of A. nuneztovari s.s. and A. dunhami, strongly (98 %) and weakly (70 %) supported, respectively. In the second phylogenetic analysis, the sequences from GenBank, identified as A. goeldii, clustered to groups I and II, but not to group III. Genetic distances (Kimura-2 parameters) among the groups ranged from 1.60 % (between I and II) to 2.32 % (between I and III). Microsatellite data revealed very high intra-population genetic variability. Genetic distances showed the highest and significant values (P = 0.005) between Tucuruí and all the other samples, and between Abacate da Pedreira and all the other samples. Genetic distances, Bayesian (Structure and BAPS) analyses and FCA suggested three distinct biological groups, supporting the barcode region results. The two markers revealed three genetic lineages for A. nuneztovari s.l. in the Brazilian Amazon region. Lineages I and II may represent genetically distinct groups or species within A. goeldii. Lineage III may represent a new species, distinct from the A. goeldii group, and may be the most ancestral in the Brazilian Amazon. They may have differences in Plasmodium susceptibility and should therefore be investigated further.

  7. Burner Rig with an Unattached Duct for Evaluating the Erosion Resistance of Thermal Barrier Coatings

    NASA Technical Reports Server (NTRS)

    Miller, Robert A.; Kuczmarski, Maria A.; Zhu, Dongming

    2011-01-01

    Extensive computational fluid dynamics (CFD) modeling backed by experimental observation has demonstrated the feasibility of using an unattached duct to increase the velocity and spatial spread of erodent particles exiting from a burner rig. It was shown that gas velocity and temperature are mostly retained if the inner diameter of the unattached duct equaled the exit diameter of the burner rig nozzle. For particles having a mean diameter of 550 millimeters, the modeled velocity attained at a distance 2.0 in. (50.8 millimeters) beyond the exit of a 12 in. (305 millimeters) long duct was approximately twice as large as the velocity the same distance from the nozzle when the duct was not present. For finer particles, the relative enhancement was somewhat less approximately 1.5 times greater. CFD modeling was also used to guide the construction of a device for slowing down the velocity of the particles being injected into the burner rig. This device used a simple 45 degree fitting to slow the particle velocity in the feed line from 20 meters per second, which is in the range needed to convey the particles, to about 3 meters per second just as they are injected into the burner. This lower injection velocity would lessen the severity of the collision of large particles with the wall of the burner liner opposite the injection port, thereby reducing potential damage to the burner liner by high-velocity particles.

  8. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Marra, Valerio; Kolb, Edward W.; Matarrese, Sabino

    Photon geodesics are calculated in a Swiss-cheese model, where the cheese is made of the usual Friedmann-Robertson-Walker (FRW) solution and the holes are constructed from a Lemaitre-Tolman-Bondi solution of Einstein's equations. The observables on which we focus are the changes in the redshift, in the angular-diameter-distance relation, in the luminosity-distance-redshift relation, and in the corresponding distance modulus. We find that redshift effects are suppressed when the hole is small because of a compensation effect acting on the scale of half a hole resulting from the special case of spherical symmetry. However, we find interesting effects in the calculation of themore » angular distance: strong evolution of the inhomogeneities (as in the approach to caustic formation) causes the photon path to deviate from that of the FRW case. Therefore, the inhomogeneities are able to partly mimic the effects of a dark-energy component. Our results also suggest that the nonlinear effects of caustic formation in cold dark matter models may lead to interesting effects on photon trajectories.« less

  9. New presentation method for magnetic resonance angiography images based on skeletonization

    NASA Astrophysics Data System (ADS)

    Nystroem, Ingela; Smedby, Orjan

    2000-04-01

    Magnetic resonance angiography (MRA) images are usually presented as maximum intensity projections (MIP), and the choice of viewing direction is then critical for the detection of stenoses. We propose a presentation method that uses skeletonization and distance transformations, which visualizes variations in vessel width independent of viewing direction. In the skeletonization, the object is reduced to a surface skeleton and further to a curve skeleton. The skeletal voxels are labeled with their distance to the original background. For the curve skeleton, the distance values correspond to the minimum radius of the object at that point, i.e., half the minimum diameter of the blood vessel at that level. The following image processing steps are performed: resampling to cubic voxels, segmentation of the blood vessels, skeletonization ,and reverse distance transformation on the curve skeleton. The reconstructed vessels may be visualized with any projection method. Preliminary results are shown. They indicate that locations of possible stenoses may be identified by presenting the vessels as a structure with the minimum radius at each point.

  10. Experimental and analytical studies in fluids

    NASA Technical Reports Server (NTRS)

    Goglia, Gene L.; Ibrahim, Adel

    1984-01-01

    The first objective was to analyze and design a true airspeed sensor which will replace the conventional pitot-static pressure transducer for small commercial aircraft. The second objective was to obtain a numerical solution and predict the frequency response which is generated by the vortex whistle at a certain airspeed. It was concluded flow rate measurements indicate that the vortex tube sound frequency is linearly proportional to the frequency response. The vortex tube whistle frequency is dependent upon geometrical parameters to such an extent that: an increase in vortex tube length produces a decrease in frequency response and that an increase in the exhaust nozzle length produces an increase in the frequency precession. An increase in the vortex tube diameter produces a decrease in frequency precession. An increase in swirler diameter produces a decrease in frequency. An increase in the location distance of the microphone pickup signal point from the inside edge of the exit nozzle produces an increase in frequency response. The experimental results indicate that those parameters most significantly effecting frequency are in descending order of importance microphone location, vortex tube diameter, exit nozzle length, vortex tube length, and swirler diameter.

  11. Measurements of droplet size in shear-driven atomization using ultra-small angle x-ray scattering

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kastengren, A.; Ilavsky, J.; Viera, Juan Pablo

    Measurements of droplet size in optically-thick, non-evaporating, shear-driven sprays have been made using ultra-small angle x-ray scattering (USAXS). The sprays are produced by orifice-type nozzles coupled to diesel injectors, with measurements conducted from 1 – 24 mm from the orifice, spanning from the optically-dense near-nozzle region to more dilute regions where optical diagnostics are feasible. The influence of nozzle diameter, liquid injection pressure, and ambient density were examined. The USAXS measurements reveal few if any nanoscale droplets, in conflict with a popular computational model of diesel spray breakup. The average droplet diameter rapidly decreases with downstream distance from the nozzlemore » until a plateau value is reached, after which only small changes are seen in droplet diameter. This plateau droplet size is consistent with the droplets being small enough to be stable with respect to further breakup. As a result, liquid injection pressure and nozzle diameter have the biggest impact on droplet size, while ambient density has a smaller effect.« less

  12. Asteroid taxonomy and the distribution of the compositional types

    NASA Technical Reports Server (NTRS)

    Zellner, B.

    1979-01-01

    Physical observations of minor planets documented in the TRIAD computer file are used to classify 752 objects into the broad compositional types C, S, M, E, R, and U (unclassifiable) according to the prescriptions adopted by Bowell et al. (1978). Diameters are computed from the photometric magnitude using radiometric and/or polarimetric data where available, or else from albedos characteristic of the indicated type. An analysis of the observational selection effects leads to tabulation of the actual number of asteroids, as a function of type and diameter, in each of 15 orbital element zones. For the whole main belt the population is 75% of type C, 15% of type S, and 10% of other types, with no belt-wide dependence of the mixing ratios on diameter. In some zones the logarithmic diameter-frequency relations are decidedly nonlinear. The relative frequency of S-type objects decreases smoothly outward through the main belt, with exponential scale length 0.5 AU. The rarer types show a more chaotic, but generally flatter, distribution over distance. Characteristic type distributions, contrasting with the background population, are found for the Eos, Koronis, Nysa and Themis families.

  13. Measurements of droplet size in shear-driven atomization using ultra-small angle x-ray scattering

    DOE PAGES

    Kastengren, A.; Ilavsky, J.; Viera, Juan Pablo; ...

    2017-03-16

    Measurements of droplet size in optically-thick, non-evaporating, shear-driven sprays have been made using ultra-small angle x-ray scattering (USAXS). The sprays are produced by orifice-type nozzles coupled to diesel injectors, with measurements conducted from 1 – 24 mm from the orifice, spanning from the optically-dense near-nozzle region to more dilute regions where optical diagnostics are feasible. The influence of nozzle diameter, liquid injection pressure, and ambient density were examined. The USAXS measurements reveal few if any nanoscale droplets, in conflict with a popular computational model of diesel spray breakup. The average droplet diameter rapidly decreases with downstream distance from the nozzlemore » until a plateau value is reached, after which only small changes are seen in droplet diameter. This plateau droplet size is consistent with the droplets being small enough to be stable with respect to further breakup. As a result, liquid injection pressure and nozzle diameter have the biggest impact on droplet size, while ambient density has a smaller effect.« less

  14. Classifying neighbourhoods by level of access to stores selling fresh fruit and vegetables and groceries: identifying problematic areas in the city of Gatineau, Quebec.

    PubMed

    Gould, Adrian C; Apparicio, Philippe; Cloutier, Marie-Soleil

    2012-11-06

    Physical access to stores selling groceries, fresh fruit and vegetables (FV) is essential for urban dwellers. In Canadian cities where low-density development practices are common, social and material deprivation may be compounded by poor geographic access to healthy food. This case study examines access to food stores selling fresh FV in Gatineau, Quebec, to identify areas where poor access is coincident with high deprivation. Food retailers were identified using two secondary sources and each store was visited to establish the total surface area devoted to the sale of fresh FV. Four population-weighted accessibility measures were then calculated for each dissemination area (DA) using road network distances. A deprivation index was created using variables from the 2006 Statistics Canada census, also at the scale of the DA. Finally, six classes of accessibility to a healthy diet were constructed using a k-means classification procedure. These were mapped and superimposed over high deprivation areas. Overall, deprivation is positively correlated with better accessibility. However, more than 18,000 residents (7.5% of the population) live in high deprivation areas characterized by large distances to the nearest retail food store (means of 1.4 km or greater) and virtually no access to fresh FV within walking distance (radius of 1 km). In this research, we identified areas where poor geographic access may introduce an additional constraint for residents already dealing with the challenges of limited financial and social resources. Our results may help guide local food security policies and initiatives.

  15. Impact of product mix and markets on the economic feasibility of hardwood thinning

    Treesearch

    John E. Baumgras; Chris B. LeDoux

    1989-01-01

    Results demonstrate how the economic feasibility of commercial hardwood thinning is impacted by tree diameter, product mix, and primary product markets. These results indicate that multiproduct harvesting can increase revenues by $0.01/ft³ to $0.32/ft³; and that small shifts in price levels or haul distance can postpone commercial thinning...

  16. Logging residue in the Pacific Northwest: characteristics affecting utilization.

    Treesearch

    James O. Howard

    1981-01-01

    Information on the characteristics of logging residue in Idaho, Washington, and Oregon is presented. Tables show volume by diameter and length, number of pieces per acre, percent of residue that is sound, distribution by slope and distance to road, and average proportion of bark. Results are shown for 19 strata (harvest method by geographic area and owner).

  17. Fluorescence lidar multi-color imaging of vegetation

    NASA Technical Reports Server (NTRS)

    Johansson, J.; Wallinder, E.; Edner, H.; Svanberg, S.

    1992-01-01

    Multi-color imaging of vegetation fluorescence following laser excitation is reported for distances of 50 m. A mobile laser radar system equipped with a Nd:YAG laser transmitter and a 40 cm diameter telescope was used. Image processing allows extraction of information related to the physiological status of the vegetation and might prove useful in forest decline research.

  18. Voyager 1 and 2 Atlas of Six Saturnian Satellites

    NASA Technical Reports Server (NTRS)

    Batson, R. M.

    1984-01-01

    Maps, compiled with data gathered primarily by Voyager 1 and 2 spacecraft, are presented which show the diversity among six of the Saturnian moons. Mimas and Enceladus are mapped in detail. Prelimary maps are given for the other four satellites. Diameter, density, albedo, and distance from mother planet, among much more data, is given for each moon.

  19. Multiple Ignition, Combustion and Quenching of Hydrocarbon Fuel Sprays.

    DTIC Science & Technology

    1984-08-01

    Its stochiometry and measuring the droplet diameter optically or with the * Impact method , the conditions of two phase mixtures in the vicinity of the...I 1 !!! II I-x 0 20 0 60 s0 100 DISTMCE FROM OT SURFt WACE In Figure 4: Hot surface temperature as function of single droplet stream distance for

  20. A single peptide loop in an alpha-Helix

    USDA-ARS?s Scientific Manuscript database

    Pitch is not a height but a ratio of rise/run. In an alpha-helix, run can be as the radius (r) from the center of the circle, as a diameter (d) measured across/bisecting a circumference, or as a distance (c) along a circumference; rise in each case can corresponds to same height (h) increase. For ...

  1. Correlation Between the Effective Neutrino Number and Curvature

    NASA Astrophysics Data System (ADS)

    Smith, Aaron; Archidiacono, M.; Cooray, A.; De Bernardis, F.; Melchiorri, A.; Smidt, J.

    2012-01-01

    Cosmological data seems to favor models with more than three neutrinos. This poster focuses on recent discussion regarding additional sterile neutrinos and neutrino mass constraints in cosmology. We present a theoretical argument for correlation between the number of effective neutrinos and the curvature of the universe. This naturally arises from simple considerations of distance measurements. For example, with the degree of damping prior to recombination fixed by observation, we find that if we allow for an open universe then the angular diameter distance increases. To counterbalance this effect the sound horizon distance must increase as well which corresponds to decreasing the effective neutrino number. This qualitative argument is confirmed by statistical analysis with CosmoMC adapted to include CMB anisotropy measurements from a variety of experiments. This research was supported by Asantha Cooray at the University of California, Irvine.

  2. Multipolar radiofrequency ablation with internally cooled electrodes: experimental study in ex vivo bovine liver with mathematic modeling.

    PubMed

    Clasen, Stephan; Schmidt, Diethard; Boss, Andreas; Dietz, Klaus; Kröber, Stefan M; Claussen, Claus D; Pereira, Philippe L

    2006-03-01

    To evaluate the size and geometry of thermally induced coagulation by using multipolar radiofrequency (RF) ablation and to determine a mathematic model to predict coagulation volume. Multipolar RF ablations (n = 80) were performed in ex vivo bovine livers by using three internally cooled bipolar applicators with two electrodes on the same shaft. Applicators were placed in a triangular array (spacing, 2-5 cm) and were activated in multipolar mode (power output, 75-225 W). The size and geometry of the coagulation zone, together with ablation time, were assessed. Mathematic functions were fitted, and the goodness of fit was assessed by using r(2). Coagulation volume, short-axis diameter, and ablation time were dependent on power output and applicator distance. The maximum zone of coagulation (volume, 324 cm(3); short-axis diameter, 8.4 cm; ablation time, 193 min) was induced with a power output of 75 W at an applicator distance of 5 cm. Coagulation volume and ablation time decreased as power output increased. Power outputs of 100-125 W at applicator distances of 2-4 cm led to a reasonable compromise between coagulation volume and ablation time. At 2 cm (100 W), coagulation volume, short-axis diameter, and ablation time were 66 cm(3), 4.5 cm, and 19 min, respectively; at 3 cm (100 W), 90 cm(3), 5.2 cm, and 22 min, respectively; at 4 cm (100 W), 132 cm(3), 6.1 cm, and 27 min, respectively; at 2 cm (125 W), 56 cm(3), 4.2 cm, and 9 min, respectively; at 3 cm (125 W), 73 cm(3), 4.9 cm, and 12 min, respectively; and at 4 cm (125 W), 103 cm(3), 5.5 cm, and 16 min, respectively. At applicator distances of 4 cm (>125 W) and 5 cm (>100 W), the zones of coagulation were not confluent. Coagulation volume (r(2) = 0.80) and RF ablation time (r(2) = 0.93) were determined by using the mathematic model. Multipolar RF ablation with three bipolar applicators may produce large volumes of confluent coagulation ex vivo. A compromise is necessary between prolonged RF ablations at lower power outputs, which produce larger volumes of coagulation, and faster RF ablations at higher power outputs, which produce smaller volumes of coagulation. Copyright RSNA, 2006.

  3. Clustering, randomness, and regularity in cloud fields: 2. Cumulus cloud fields

    NASA Astrophysics Data System (ADS)

    Zhu, T.; Lee, J.; Weger, R. C.; Welch, R. M.

    1992-12-01

    During the last decade a major controversy has been brewing concerning the proper characterization of cumulus convection. The prevailing view has been that cumulus clouds form in clusters, in which cloud spacing is closer than that found for the overall cloud field and which maintains its identity over many cloud lifetimes. This "mutual protection hypothesis" of Randall and Huffman (1980) has been challenged by the "inhibition hypothesis" of Ramirez et al. (1990) which strongly suggests that the spatial distribution of cumuli must tend toward a regular distribution. A dilemma has resulted because observations have been reported to support both hypotheses. The present work reports a detailed analysis of cumulus cloud field spatial distributions based upon Landsat, Advanced Very High Resolution Radiometer, and Skylab data. Both nearest-neighbor and point-to-cloud cumulative distribution function statistics are investigated. The results show unequivocally that when both large and small clouds are included in the cloud field distribution, the cloud field always has a strong clustering signal. The strength of clustering is largest at cloud diameters of about 200-300 m, diminishing with increasing cloud diameter. In many cases, clusters of small clouds are found which are not closely associated with large clouds. As the small clouds are eliminated from consideration, the cloud field typically tends towards regularity. Thus it would appear that the "inhibition hypothesis" of Ramirez and Bras (1990) has been verified for the large clouds. However, these results are based upon the analysis of point processes. A more exact analysis also is made which takes into account the cloud size distributions. Since distinct clouds are by definition nonoverlapping, cloud size effects place a restriction upon the possible locations of clouds in the cloud field. The net effect of this analysis is that the large clouds appear to be randomly distributed, with only weak tendencies towards regularity. For clouds less than 1 km in diameter, the average nearest-neighbor distance is equal to 3-7 cloud diameters. For larger clouds, the ratio of cloud nearest-neighbor distance to cloud diameter increases sharply with increasing cloud diameter. This demonstrates that large clouds inhibit the growth of other large clouds in their vicinity. Nevertheless, this leads to random distributions of large clouds, not regularity.

  4. Yarkovsky-driven Impact Predictions: Apophis and 1950 DA

    NASA Astrophysics Data System (ADS)

    Chesley, Steven R.; Farnocchia, D.; Chodas, P. W.; Milani, A.

    2013-10-01

    Orbit determination for Near-Earth Asteroids presents unique technical challenges due to the imperative of early detection and careful assessment of the risk posed by specific Earth close approaches. The occurrence of an Earth impact can be decisively driven by the Yarkovsky effect, which is the most important nongravitational perturbation as it causes asteroids to undergo a secular variation in semimajor axis resulting in a quadratic effect in anomaly. We discuss the cases of (99942) Apophis and (29075) 1950 DA. The relevance of the Yarkovsky effect for Apophis is due to a scattering close approach in 2029 with minimum geocentric distance ~38000 km. For 1950 DA the influence of the Yarkovsky effect in 2880 is due to the long time interval preceding the impact. We use the available information from the astrometry and the asteroids' physical models and dynamical evolution as a starting point for a Monte Carlo method that allows us to measure how the Yarkovsky effect affects orbital predictions. We also find that 1950 DA has a 98% likelihood of being a retrograde rotator. For Apophis we map onto the 2029 close approach b-plane and analyze the keyholes corresponding to resonant close approaches. For 1950 DA we use the b-plane corresponding to the possible impact in 2880. We finally compute the impact probability from the mapped probability density function on the considered b-plane. For Apophis we have 4 in a million chances of an impact in 2068, while the probability of Earth impact in 2880 for 1950 DA is 0.04%.

  5. Local classification: Locally weighted-partial least squares-discriminant analysis (LW-PLS-DA).

    PubMed

    Bevilacqua, Marta; Marini, Federico

    2014-08-01

    The possibility of devising a simple, flexible and accurate non-linear classification method, by extending the locally weighted partial least squares (LW-PLS) approach to the cases where the algorithm is used in a discriminant way (partial least squares discriminant analysis, PLS-DA), is presented. In particular, to assess which category an unknown sample belongs to, the proposed algorithm operates by identifying which training objects are most similar to the one to be predicted and building a PLS-DA model using these calibration samples only. Moreover, the influence of the selected training samples on the local model can be further modulated by adopting a not uniform distance-based weighting scheme which allows the farthest calibration objects to have less impact than the closest ones. The performances of the proposed locally weighted-partial least squares-discriminant analysis (LW-PLS-DA) algorithm have been tested on three simulated data sets characterized by a varying degree of non-linearity: in all cases, a classification accuracy higher than 99% on external validation samples was achieved. Moreover, when also applied to a real data set (classification of rice varieties), characterized by a high extent of non-linearity, the proposed method provided an average correct classification rate of about 93% on the test set. By the preliminary results, showed in this paper, the performances of the proposed LW-PLS-DA approach have proved to be comparable and in some cases better than those obtained by other non-linear methods (k nearest neighbors, kernel-PLS-DA and, in the case of rice, counterpropagation neural networks). Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Anatomic and hemodynamic evaluation of renal venous flow in varicocele formation using color Doppler sonography with emphasis on renal vein entrapment syndrome.

    PubMed

    Unlu, Murat; Orguc, Sebnem; Serter, Selim; Pekindil, Gokhan; Pabuscu, Yuksel

    2007-01-01

    To investigate the anatomic and hemodynamic properties of testicular venous drainage and its effects on varicocele formation and reflux using color Doppler ultrasound (US) with emphasis on renal vein entrapment syndrome. Upper abdominal and scrotal US examinations of 35 varicocele patients and 35 healthy male subjects were performed in the supine position during rest, during a Valsalva maneuver and in the erect position. The aortomesenteric angle and distance (AMA and AMD, respectively), peak mean velocities (PVs) and diameters of different segments of renal veins, testicular vein diameters and duration of flow inversion were measured. In the varicocele group, the lateral segment of the left renal vein (LRV) had a larger diameter and slower PV, and the medial segment of the LRV had a smaller diameter and faster PV. The diameter of the dominant draining vein correlated with the PV of the medial and lateral segments of the LRV, whereas there was no correlation between the diameter of the dominant draining vein and the diameters of the right renal vein (RRV) and the lateral segment of the LRV or the PV of the RRV. The duration of flow inversion correlated with the diameter and PV of the medial segment of the LRV. No correlation between the diameters and PVs of the RRV and the lateral segment of the LRV was detected. The decreases in the AMA, AMD, diameter of the medial segment of the LRV and PV of the lateral segment of the LRV, and the increases in the PV of the medial segment of the LRV and the diameter of the lateral segment of the LRV in varicocele patients in all positions suggest the entrapment or impingement of the left renal vein between the aorta and the superior mesenteric artery. This has been defined as the "nutcracker phenomenon", which is known to affect varicocele formation.

  7. Parotid Branches of the Auriculotemporal Nerve: An Anatomical Study With Implications for Frey Syndrome.

    PubMed

    Iwanaga, Joe; Fisahn, Christian; Watanabe, Koichi; Bobek, Samuel L; Ogata, Kinuko; Tanoue, Ryuichiro; Kusukawa, Jingo; Oskouian, Rod J; Tubbs, R Shane

    2017-01-01

    The auriculotemporal nerve is one of the many branches of the mandibular division of the trigeminal nerve. Of these, its superficial temporal branch has been most described. Although the parotid branches, secretomotor fibers to the parotid gland, are well known as the cause of Frey syndrome, there have been almost no descriptions of their anatomy. In this study, the authors dissected the parotid branches of the auriculotemporal nerve to elucidate their anatomy. A total of 10 sides from 7 adult and embalmed cadaver heads were used in this study. The specimens were derived from 3 males and 4 females, the age of cadavers at death ranged from 65 to 92 years old. Measurements included their diameter and the distance of their branching point from the main trunk of the auriculotemporal nerve from the middle of the tragus. Three of 10 sides had 2 parotid branches and 7 sides were found to have 1 parotid branch. The vertical distance between middle of the tragus to branching point of the parotid branch ranged from 1.79 to 16.17 mm. The horizontal distance between middle of the tragus to branching point of the parotid branch ranged from 3.03 to 12.62 mm. The diameter of the parotid branch ranged from 0.31 to 0.49 mm. An improved knowledge of the parotid branch of the auriculotemporal nerve might decrease injury to these structures with the potential for postoperative.

  8. A model for the effect of submerged aquatic vegetation on turbulence induced by an oscillating grid

    NASA Astrophysics Data System (ADS)

    Pujol, Dolors; Colomer, Jordi; Serra, Teresa; Casamitjana, Xavier

    2012-12-01

    The aim of this study is to model, under controlled laboratory conditions, the effect of submerged aquatic vegetation (SAV) on turbulence generated in a water column by an oscillating grid turbulence (OGT). Velocity profiles have been measured by an acoustic Doppler velocimeter (MicroADV). Experimental conditions are analysed in two canopy models (rigid and semi-rigid), using nine plant-to-plant distances (ppd), three stem diameters (d), four types of natural SAV (Cladium mariscus, Potamogeton nodosus, Myriophyllum verticillatum and Ruppia maritima) and two oscillation grid frequencies (f). To quantify this response, we have developed a non-dimensional model, with a specific turbulent kinetic energy (TKE), f, stroke (s), d, ppd, distance from the virtual origin to the measurement (zm) and space between grid bars (M). The experimental data show that, at zm/zc < 1 the turbulent kinetic energy decays with zm, according to the well-known power law, zm-2, and does not depend on the vegetation characteristics. In contrast, at zm/zc > 1, TKE decreases faster with zm and scales to the model variables according to TKE/(f·s)∝(·(. Therefore, at zm/zc > 1 the TKE is affected by the geometric characteristics of the plants (both diameter and plant-to-plant distance), an effect called sheltering. Results from semi-rigid canopies and natural SAV are found to scale with the non-dimensional model proposed for rigid canopies. We also discuss the practical implications for field conditions (wind and natural SAV).

  9. Shortest Distance From Fovea to Subfoveal Hemorrhage Border Is Important in Patients With Neovascular Age-related Macular Degeneration.

    PubMed

    Kherani, Saleema; Scott, Adrienne W; Wenick, Adam S; Zimmer-Galler, Ingrid; Brady, Christopher J; Sodhi, Akrit; Meyerle, Catherine; Solomon, Sharon D; Shaukat, Rimsha; Channa, Roomasa; Adeyemo, Olukemi; Handa, James T; Wang, Jiangxia; Campochiaro, Peter A

    2018-05-01

    To identify factors influencing visual outcome in patients with neovascular age-related macular degeneration (NVAMD) and subfoveal hemorrhage (SFH) treated with anti-vascular endothelial growth factor (VEGF) agents. Retrospective case series. Anti-VEGF-treated eyes with SFH > 1 disc area (DA) were identified (n = 16) and changes in visual acuity (VA) and central subfield thickness (CST) from baseline to last follow-up, along with SFH area, thickness, minimum distance from fovea to SFH border, and time to resolution, were determined. At baseline, mean (± standard error of the mean) size and thickness of SFH were 14.9 ± 2.8 DA and 386.6 ± 46.9 μm, and mean Snellen VA and CST were 20/250 and 591.7 ± 57.0 μm. Median follow-up was 47.6 months. While more than 50% of patients had VA ≤ 20/200 at baseline and all time points through week 48, the percentage of patients with VA ≥ 20/50 increased to 30%-40% at months 6 and 12 and remained stable through month 48. Spearman rank correlation demonstrated 2 independent variables that correlated with good visual outcome, smaller area of SFH at baseline (r = -0.630; P = .009), and high frequency of anti-VEGF injections (r = 0.646; P = .007). In exceptional patients with good visual outcome despite large baseline SFH, shortest distance between the fovea and hemorrhage border significantly correlated with baseline VA (r = -0.503, P = .047) and final VA (r = -0.575, P = .02). Patients with NVAMD and thick SFH, but short distance between fovea and uninvolved retina, can have good visual outcomes when given frequent anti-VEGF injections. Copyright © 2018 Elsevier Inc. All rights reserved.

  10. Morphometric features of posterior cranial fossa are different between Chiari I malformation with and without syringomyelia.

    PubMed

    Yan, Huang; Han, Xiao; Jin, Mengran; Liu, Zhen; Xie, Dingding; Sha, Shifu; Qiu, Yong; Zhu, Zezhang

    2016-07-01

    To investigate whether the posterior cranial fossa (PCF) morphology in Chiari I malformation without syringomyelia (also called syrinx) (CMI-only) is different from that in Chiari I malformation with syrinx (CMI-S). Nineteen CMI patients without syrinx constituted the CMI-only group, whereas 48 CMI patients with syrinx were assigned to the CMI-S group. Another cohort of 40 age-matched asymptomatic adolescents was enrolled to serve as the control group. Six measurements were evaluated and compared between these three groups from T1-weighted magnetic resonance (MR) imaging, including the length of the clivus (AB), the anteroposterior diameter of the foramen magnum (BC), the length of the supraocciput (CD), the anteroposterior diameter of the posterior fossa (DA), the posterior fossa height (BE) and the clivus gradient ([Formula: see text]). The posterior cranial fossa morphology in relation to syrinx severity was also investigated. Compared to the normal controls, the AB, CD, DA, BE and [Formula: see text] were significantly larger in the CMI-S group. Similar changes in AB, CD, DA and BE were also demonstrated in the CMI-only group, while the clivus gradient ([Formula: see text]) was found to be normal when compared with the control group. A significantly decreased clivus gradient was observed in the CMI-S group as compared to CMI-only group. In addition, the clivus was significantly flattened in patients with a distended-syrinx in comparison to those with a non-distended syrinx. Small size of the posterior fossa was detected both in CMI cases with and without syrinx. The clivus gradient served as the only morphologic difference in the PCF between CMI-S and CMI-only patients and was correlated with the severity of the syrinx, may support the theory that the restricted circulation of cerebrospinal fluid at the anterior paramedial subarachnoid space contributes to the formation of a syrinx.

  11. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lindsay, P. E., E-mail: Patricia.Lindsay@rmp.uhn.on.ca; Granton, P. V.; Hoof, S. van

    Purpose: To compare the dosimetric and geometric properties of a commercial x-ray based image-guided small animal irradiation system, installed at three institutions and to establish a complete and broadly accessible commissioning procedure. Methods: The system consists of a 225 kVp x-ray tube with fixed field size collimators ranging from 1 to 44 mm equivalent diameter. The x-ray tube is mounted opposite a flat-panel imaging detector, on a C-arm gantry with 360° coplanar rotation. Each institution performed a full commissioning of their system, including half-value layer, absolute dosimetry, relative dosimetry (profiles, percent depth dose, and relative output factors), and characterization ofmore » the system geometry and mechanical flex of the x-ray tube and detector. Dosimetric measurements were made using Farmer-type ionization chambers, small volume air and liquid ionization chambers, and radiochromic film. The results between the three institutions were compared. Results: At 225 kVp, with 0.3 mm Cu added filtration, the first half value layer ranged from 0.9 to 1.0 mm Cu. The dose-rate in-air for a 40 × 40 mm{sup 2} field size, at a source-to-axis distance of 30 cm, ranged from 3.5 to 3.9 Gy/min between the three institutions. For field sizes between 2.5 mm diameter and 40 × 40 mm{sup 2}, the differences between percent depth dose curves up to depths of 3.5 cm were between 1% and 4% on average, with the maximum difference being 7%. The profiles agreed very well for fields >5 mm diameter. The relative output factors differed by up to 6% for fields larger than 10 mm diameter, but differed by up to 49% for fields ≤5 mm diameter. The mechanical characteristics of the system (source-to-axis and source-to-detector distances) were consistent between all three institutions. There were substantial differences in the flex of each system. Conclusions: With the exception of the half-value layer, and mechanical properties, there were significant differences between the dosimetric and geometric properties of the three systems. This underscores the need for careful commissioning of each individual system for use in radiobiological experiments.« less

  12. Comparing the eyes depicted in Japanese portraits of beautiful women: the Meiji and modern periods.

    PubMed

    Lee, James J; Thomas, Ewart

    2012-06-01

    The women portrayed in the bijin-ga of the past, particularly those from the Meiji Period (1868–1912), tended not to show much resemblance to those of women portrayed in the more modern bijin-ga (from after World War II), and such an observation came across as a possible indication that Japanese standards of beauty have changed over the two eras. To examine whether the apparent discrepancy can be interpreted as an actual change in the standards or not, a study was designed with the aim of assigning numeric values to several aspects of the eyes and testing for the presence of a statistically significant difference in each of the aspects between the Meiji bijin-ga and the modern bijin-ga. For this study, 29 Meiji bijin-ga and 36 modern bijin-ga were selected. The eye was chosen as the subject of comparison, and five aspects were categorized and measured: (1) presence or absence of a double fold, (2) eye width, (3) eye height, (4) eyebrow-to-upper lid distance, and (D) corneal diameter. The eye width, the eye height, and the eyebrow-to-upper lid distance were divided by the corneal diameter to derive standardized grounds for comparison. The difference in double-fold frequencies between the Meiji bijin-ga (24%) and the modern bijin-ga (36%) was not found to be statistically significant (p=0.298). There was no difference in the eye width-to-corneal diameter ratio between the Meiji bijin-ga (mean 2.57±0.6) and the modern bijin-ga (mean 2.61±0.85) (p=0.86). The eye height-to-corneal diameter ratio derived from the Meiji bijin-ga (mean 0.62±0.15) was significantly smaller than that derived from the modern bijin-ga (mean 0.82±0.18) (p=0.000). The eyebrow to upper lid distance-to-corneal diameter ratio derived from the Meiji bijin-ga (mean 2.21±0.83) was significantly greater than that derived from the modern bijin-ga (mean 1.36±0.78) (p=0.000). The results of the study support the notion that Westernization contributed to bringing about changes in the Japanese standards of beautiful eyes in the context of bijin-ga. However, the fact that the changeover has not occurred in all the categories in question does not indicate that the Occidental characteristics came to be emulated in their entirety. This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to the Table of Contents or the online Instructions to Authors at http://www.springer.com/00266.

  13. Double diameter boring tool

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ashbaugh, F.N.; Murry, K.R.

    A method of boring two concentric holes of different depths is described utilizing an elongated boring tool having a tool axis of rotation, a longitudinally disposed tool centerline axis, and first and second transverse cutting edges at one end thereof extending across the boring tool, the second cutting edge being longitudinally rearwardly recessed with respect to the first cutting edge. The method consists of inserting the boring tool into an adjustable boring head, adjusting a distance B between the tool centerline axis and the tool axis of rotation such that the tool axis of rotation intersects a first boring areamore » of the first cutting edge; and boring the concentric holes having respectively larger and smaller diameters.« less

  14. Three Dimensional Parametric Analyses of Stress Concentration Factor and Its Mitigation in Isotropic and Orthotropic Plate with Central Circular Hole Under Axial In-Plane Loading

    NASA Astrophysics Data System (ADS)

    Nagpal, Shubhrata; Jain, Nitin Kumar; Sanyal, Shubhashis

    2016-01-01

    The problem of finding the stress concentration factor of a loaded rectangular plate has offered considerably analytical difficulty. The present work focused on understanding of behavior of isotropic and orthotropic plate subjected to static in-plane loading using finite element method. The complete plate model configuration has been analyzed using finite element method based software ANSYS. In the present work two parameters: thickness to width of plate (T/A) and diameter of hole to width of plate (D/A) have been varied for analysis of stress concentration factor (SCF) and its mitigation. Plates of five different materials have been considered for complete analysis to find out the sensitivity of stress concentration factor. The D/A ratio varied from 0.1 to 0.7 for analysis of SCF and varied from 0.1 to 0.5 for analyzing the mitigation of SCF. 0.01, 0.05 and 0.1 are considered as T/A ratio for all the cases. The results are presented in graphical form and discussed. The mitigation in SCF reported is very encouraging. The SCF is more sensitive to D/A ratio as compared to T/A.

  15. Poly(D,L-Lactide-Co-Glycolide) Tubes With Multifilament Chitosan Yarn or Chitosan Sponge Core in Nerve Regeneration.

    PubMed

    Wlaszczuk, Adam; Marcol, Wiesław; Kucharska, Magdalena; Wawro, Dariusz; Palen, Piotr; Lewin-Kowalik, Joanna

    2016-11-01

    The influence of different kinds of nerve guidance conduits on regeneration of totally transected rat sciatic nerves through a 7-mm gap was examined. Five different types of conduits made of chitosan and poly(D,L-lactide-co-glycolide) (PLGA) were constructed and tested in vivo. We divided 50 animals into equal groups of 10, with a different type of conduit implanted in each group: chitosan sponge core with an average molecular mass of polymer (Mv) of 287 kDa with 7 channels in a PLGA sleeve, chitosan sponge core with an Mv of 423 kDa with 7 channels in a PLGA sleeve, chitosan sponge core (Mv, 423 kDa) with 13 channels in a PLGA sleeve, chitosan multifilament yarn in a PLGA sleeve, and a PLGA sleeve only. Seven weeks after the operation, we examined the distance covered by regenerating nerve fibers, growing of nerves into the conduit's core, and intensity and type of inflammatory reaction in the conduit, as well as autotomy behavior (reflecting neuropathic pain intensity) in the animals. Two types of conduits were allowing nerve outgrowth through the gap with minor autotomy and minor inflammatory reactions. These were the conduits with chitosan multifilament yarn in a PLGA sleeve and the conduits with 13-channel microcrystalline chitosan sponge in a PLGA sleeve. The type of chitosan used to build the nerve guidance conduit influences the intensity and character of inflammatory reaction present during nerve regeneration, which in turn affects the distance crossed by regenerating nerve fibers, growing of the nerve fibers into the conduit's core, and the intensity of autotomy in the animals. Copyright © 2016 American Association of Oral and Maxillofacial Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Autoregulation and tubuloglomerular feedback in juxtamedullary glomerular arterioles.

    PubMed

    Casellas, D; Moore, L C

    1990-03-01

    Videometric measurements of changes in vessel lumen diameters were made to investigate autoregulatory and tubuloglomerular feedback (TGF) responses of early efferent arterioles (EA), mid-to-late afferent arterioles (MAA), and terminal, juxtaglomerular afferent arterioles (JAA) in rat juxtamedullary nephrons in vitro. High-contrast shadow-cast images of blood-perfused arterioles at the glomerular vascular pole were obtained with incident illumination and long-working-distance objectives fitted to a compound microscope. In response to an increase in blood perfusion pressure from 60 to 140 mmHg, strong autoregulatory vasoconstriction was observed in the MAA and JAA, with respective reductions in mean luminal diameter of 23 +/- 4 and 40 +/- 4% (mean +/- SE); EA diameter was unchanged. In response to TGF excitation by direct microinjection of Ringer solution into the cortical thick ascending limb segment near the macula densa, JAA luminal diameter decreased by 34 +/- 5%. The TGF responses were completely inhibited by the addition of 0.1 mM furosemide to the tubular injectate. Calcium channel blockade achieved by adding 1 microM nimodipine to the superfusate had no effect on early EA diameter but produced a blood pressure-dependent JAA and MAA vasodilation and complete inhibition of autoregulatory responses. These results provide direct evidence that the distal afferent arteriole in juxtamedullary nephrons is a major effector site for both renal autoregulation and tubuloglomerular feedback.

  17. Fabrication of an Optical Fiber Micro-Sphere with a Diameter of Several Tens of Micrometers.

    PubMed

    Yu, Huijuan; Huang, Qiangxian; Zhao, Jian

    2014-06-25

    A new method to fabricate an integrated optical fiber micro-sphere with a diameter within 100 µm, based on the optical fiber tapering technique and the Taguchi method is proposed. Using a 125 µm diameter single-mode (SM) optical fiber, an optical fiber taper with a cone angle is formed with the tapering technique, and the fabrication optimization of a micro-sphere with a diameter of less than 100 µm is achieved using the Taguchi method. The optimum combination of process factors levels is obtained, and the signal-to-noise ratio (SNR) of three quality evaluation parameters and the significance of each process factors influencing them are selected as the two standards. Using the minimum zone method (MZM) to evaluate the quality of the fabricated optical fiber micro-sphere, a three-dimensional (3D) numerical fitting image of its surface profile and the true sphericity are subsequently realized. From the results, an optical fiber micro-sphere with a two-dimensional (2D) diameter less than 80 µm, 2D roundness error less than 0.70 µm, 2D offset distance between the micro-sphere center and the fiber stylus central line less than 0.65 µm, and true sphericity of about 0.5 µm, is fabricated.

  18. Ecological Importance of Large-Diameter Trees in a Temperate Mixed-Conifer Forest

    PubMed Central

    Lutz, James A.; Larson, Andrew J.; Swanson, Mark E.; Freund, James A.

    2012-01-01

    Large-diameter trees dominate the structure, dynamics and function of many temperate and tropical forests. Although both scaling theory and competition theory make predictions about the relative composition and spatial patterns of large-diameter trees compared to smaller diameter trees, these predictions are rarely tested. We established a 25.6 ha permanent plot within which we tagged and mapped all trees ≥1 cm dbh, all snags ≥10 cm dbh, and all shrub patches ≥2 m2. We sampled downed woody debris, litter, and duff with line intercept transects. Aboveground live biomass of the 23 woody species was 507.9 Mg/ha, of which 503.8 Mg/ha was trees (SD = 114.3 Mg/ha) and 4.1 Mg/ha was shrubs. Aboveground live and dead biomass was 652.0 Mg/ha. Large-diameter trees comprised 1.4% of individuals but 49.4% of biomass, with biomass dominated by Abies concolor and Pinus lambertiana (93.0% of tree biomass). The large-diameter component dominated the biomass of snags (59.5%) and contributed significantly to that of woody debris (36.6%). Traditional scaling theory was not a good model for either the relationship between tree radii and tree abundance or tree biomass. Spatial patterning of large-diameter trees of the three most abundant species differed from that of small-diameter conspecifics. For A. concolor and P. lambertiana, as well as all trees pooled, large-diameter and small-diameter trees were spatially segregated through inter-tree distances <10 m. Competition alone was insufficient to explain the spatial patterns of large-diameter trees and spatial relationships between large-diameter and small-diameter trees. Long-term observations may reveal regulation of forest biomass and spatial structure by fire, wind, pathogens, and insects in Sierra Nevada mixed-conifer forests. Sustaining ecosystem functions such as carbon storage or provision of specialist species habitat will likely require different management strategies when the functions are performed primarily by a few large trees as opposed to many smaller trees. PMID:22567132

  19. Both structural and non-structural forms of the readthrough protein of cucurbit aphid-borne yellows virus are essential for efficient systemic infection of plants.

    PubMed

    Boissinot, Sylvaine; Erdinger, Monique; Monsion, Baptiste; Ziegler-Graff, Véronique; Brault, Véronique

    2014-01-01

    Cucurbit aphid-borne yellows virus (CABYV) is a polerovirus (Luteoviridae family) with a capsid composed of the major coat protein and a minor component referred to as the readthrough protein (RT). Two forms of the RT were reported: a full-length protein of 74 kDa detected in infected plants and a truncated form of 55 kDa (RT*) incorporated into virions. Both forms were detected in CABYV-infected plants. To clarify the specific roles of each protein in the viral cycle, we generated by deletion a polerovirus mutant able to synthesize only the RT* which is incorporated into the particle. This mutant was unable to move systemically from inoculated leaves inferring that the C-terminal half of the RT is required for efficient long-distance transport of CABYV. Among a collection of CABYV mutants bearing point mutations in the central domain of the RT, we obtained a mutant impaired in the correct processing of the RT which does not produce the RT*. This mutant accumulated very poorly in upper non-inoculated leaves, suggesting that the RT* has a functional role in long-distance movement of CABYV. Taken together, these results infer that both RT proteins are required for an efficient CABYV movement.

  20. Both Structural and Non-Structural Forms of the Readthrough Protein of Cucurbit aphid-borne yellows virus Are Essential for Efficient Systemic Infection of Plants

    PubMed Central

    Boissinot, Sylvaine; Erdinger, Monique; Monsion, Baptiste; Ziegler-Graff, Véronique; Brault, Véronique

    2014-01-01

    Cucurbit aphid-borne yellows virus (CABYV) is a polerovirus (Luteoviridae family) with a capsid composed of the major coat protein and a minor component referred to as the readthrough protein (RT). Two forms of the RT were reported: a full-length protein of 74 kDa detected in infected plants and a truncated form of 55 kDa (RT*) incorporated into virions. Both forms were detected in CABYV-infected plants. To clarify the specific roles of each protein in the viral cycle, we generated by deletion a polerovirus mutant able to synthesize only the RT* which is incorporated into the particle. This mutant was unable to move systemically from inoculated leaves inferring that the C-terminal half of the RT is required for efficient long-distance transport of CABYV. Among a collection of CABYV mutants bearing point mutations in the central domain of the RT, we obtained a mutant impaired in the correct processing of the RT which does not produce the RT*. This mutant accumulated very poorly in upper non-inoculated leaves, suggesting that the RT* has a functional role in long-distance movement of CABYV. Taken together, these results infer that both RT proteins are required for an efficient CABYV movement. PMID:24691251

  1. Supramolecular control of the spin-dependent dynamics of long-lived charge-separated states at the micellar interface as studied by magnetic field effect.

    PubMed

    Miura, Tomoaki

    2013-05-30

    Spin selectivity in long-lived charge separation at the micellar interface is studied using the magnetic field effect (MFE). An amphiphilic viologen is complexed with a nonionic surfactant to form a supramolecular acceptor cage, of which the size is controlled by the acceptor concentration, as confirmed by dynamic light scattering measurement. Photoinduced electron transfer (ET) from a guest polyaromatic molecule to the viologen moiety is observed spin-dependently with time-resolved fluorescence (trFL) and transient absorption (TA). A negative MFE on the radical yield is successfully observed, which indicates generation of singlet-born long-lived radical pair that is realized by supramolecular control of the donor-acceptor (D-A) distances. The dominance of the singlet-precursor MFE is sensitive to the acceptor concentration, which presumably affects the D-A distance as well as the cage size. However, theoretical analysis of the MFE gives large recombination rates of ca. 10(8) s(-1), which indicate the contribution of spin-allowed recombination of the pseudocontact radical pair generated by still active in-cage diffusion. Dependence of the viologen concentration and alkyl chain length on the recombination and escape dynamics is discussed in terms of precursor spin states and the microenvironments in the cage.

  2. Diffusive oxygen shunting between vessels in the preglomerular renal vasculature: anatomic observations and computational modeling.

    PubMed

    Gardiner, Bruce S; Thompson, Sarah L; Ngo, Jennifer P; Smith, David W; Abdelkader, Amany; Broughton, Brad R S; Bertram, John F; Evans, Roger G

    2012-09-01

    To understand how geometric factors affect arterial-to-venous (AV) oxygen shunting, a mathematical model of diffusive oxygen transport in the renal cortex was developed. Preglomerular vascular geometry was investigated using light microscopy (providing vein shape, AV separation, and capillary density near arteries) and published micro-computed tomography (CT) data (providing vessel size and AV separation; Nordsletten DA, Blackett S, Bentley MD, Ritman EL, Smith NP. IUPS Physiome Project. http://www.physiome.org.nz/publications/nordsletten_blackett_ritman_bentley_smith_2005/folder_contents). A "U-shaped" relationship was observed between the arterial radius and the distance between the arterial and venous lumens. Veins were found to partially wrap around the artery more consistently for larger rather than smaller arteries. Intrarenal arteries were surrounded by an area of fibrous tissue, lacking capillaries, the thickness of which increased from ∼5 μm for the smallest arteries (<16-μm diameter) to ∼20 μm for the largest arteries (>200-μm diameter). Capillary density was greater near smaller arteries than larger arteries. No capillaries were observed between wrapped AV vessel pairs. The computational model comprised a single AV pair in cross section. Geometric parameters critical in renal oxygen transport were altered according to variations observed by CT and light microscopy. Lumen separation and wrapping of the vein around the artery were found to be the critical geometric factors determining the amount of oxygen shunted between AV pairs. AV oxygen shunting increases both as lumen separation decreases and as the degree of wrapping increases. The model also predicts that capillaries not only deliver oxygen, but can also remove oxygen from the cortical parenchyma close to an AV pair. Thus the presence of oxygen sinks (capillaries or tubules) near arteries would reduce the effectiveness of AV oxygen shunting. Collectively, these data suggest that AV oxygen shunting would be favored in larger vessels common to the cortical and medullary circulations (i.e., arcuate and proximal interlobular arteries) rather than the smaller vessels specific to the cortical circulation (distal interlobular arteries and afferent arterioles).

  3. Yarkovsky-driven Impact Predictions: Apophis and 1950 DA

    NASA Astrophysics Data System (ADS)

    Farnocchia, Davide; Chesley, S. R.; Chodas, P.; Milani, A.

    2013-05-01

    Abstract (2,250 Maximum Characters): Orbit determination for Near-Earth Asteroids presents unique technical challenges due to the imperative of early detection and careful assessment of the risk posed by specific Earth close approaches. The occurrence of an Earth impact can be decisively driven by the Yarkovsky effect, which is the most important nongravitational perturbation as it causes asteroids to undergo a secular variation in semimajor axis resulting in a quadratic effect in anomaly. We discuss the cases of (99942) Apophis and (29075) 1950 DA. The relevance of the Yarkovsky effect for Apophis is due to a scattering close approach in 2029 with minimum geocentric distance ~38000 km. For 1950 DA the influence of the Yarkovsky effect in 2880 is due to the long time interval preceding the impact. We use the available information on the asteroids' physical models as a starting point for a Monte Carlo method that allow us to measure how the Yarkovsky effect affects orbital predictions. For Apophis we map onto the 2029 close approach b-plane and analyze the keyholes corresponding to resonant close approaches. For 1950 DA we use the b-plane corresponding to the possible impact in 2880. We finally compute the impact probability from the mapped probability density function on the considered b-plane.

  4. Piloted simulation of a ground-based time-control concept for air traffic control

    NASA Technical Reports Server (NTRS)

    Davis, Thomas J.; Green, Steven M.

    1989-01-01

    A concept for aiding air traffic controllers in efficiently spacing traffic and meeting scheduled arrival times at a metering fix was developed and tested in a real time simulation. The automation aid, referred to as the ground based 4-D descent advisor (DA), is based on accurate models of aircraft performance and weather conditions. The DA generates suggested clearances, including both top-of-descent-point and speed-profile data, for one or more aircraft in order to achieve specific time or distance separation objectives. The DA algorithm is used by the air traffic controller to resolve conflicts and issue advisories to arrival aircraft. A joint simulation was conducted using a piloted simulator and an advanced concept air traffic control simulation to study the acceptability and accuracy of the DA automation aid from both the pilot's and the air traffic controller's perspectives. The results of the piloted simulation are examined. In the piloted simulation, airline crews executed controller issued descent advisories along standard curved path arrival routes, and were able to achieve an arrival time precision of + or - 20 sec at the metering fix. An analysis of errors generated in turns resulted in further enhancements of the algorithm to improve the predictive accuracy. Evaluations by pilots indicate general support for the concept and provide specific recommendations for improvement.

  5. The influence of distance between microbubbles on the fluid flow produced during ultrasound exposure

    PubMed Central

    Schutt, Carolyn E.; Ibsen, Stuart D.; Thrift, William; Esener, Sadik C.

    2014-01-01

    The collapse dynamics of lipid monolayer-coated microbubbles in the clinically-relevant size range under 6 μm in diameter have not been studied directly due to their small size obscuring the collapse visualization. This study investigates the influence of inter-microbubble distance on the shape of lipid debris clouds created by the collapse of the microbubble destroying the microbubble lipid monolayer. The shape was highly influenced by the fluid motion that occurred as the microbubbles collapsed. It was observed that at inter-microbubble distances smaller than 37 μm the microbubbles began to interact with one another resulting in distorted and ellipsoid-shaped debris clouds. At inter-microbubble distances less than 10 μm, significantly elongated debris clouds were observed that extended out from the original microbubble location in a single direction. These distortions show a significant distance-dependent interaction between microbubbles. It was observed that microbubbles in physical contact with one another behaved in the same manner as separate microbubbles less than 10 μm apart creating significantly elongated debris clouds. It can be hypothesized that small inter-microbubble distances influence the microbubble to collapse asymmetrically resulting in the creation of fluid jets that contribute to the formation of debris fields that are elongated in a single direction. PMID:25480086

  6. Estimation of distances to stars with stellar parameters from LAMOST

    DOE PAGES

    Carlin, Jeffrey L.; Liu, Chao; Newberg, Heidi Jo; ...

    2015-06-05

    Here, we present a method to estimate distances to stars with spectroscopically derived stellar parameters. The technique is a Bayesian approach with likelihood estimated via comparison of measured parameters to a grid of stellar isochrones, and returns a posterior probability density function for each star's absolute magnitude. We tailor this technique specifically to data from the Large Sky Area Multi-object Fiber Spectroscopic Telescope (LAMOST) survey. Because LAMOST obtains roughly 3000 stellar spectra simultaneously within each ~5-degree diameter "plate" that is observed, we can use the stellar parameters of the observed stars to account for the stellar luminosity function and targetmore » selection effects. This removes biasing assumptions about the underlying populations, both due to predictions of the luminosity function from stellar evolution modeling, and from Galactic models of stellar populations along each line of sight. Using calibration data of stars with known distances and stellar parameters, we show that our method recovers distances for most stars within ~20%, but with some systematic overestimation of distances to halo giants. We apply our code to the LAMOST database, and show that the current precision of LAMOST stellar parameters permits measurements of distances with ~40% error bars. This precision should improve as the LAMOST data pipelines continue to be refined.« less

  7. Estimation of distances to stars with stellar parameters from LAMOST

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Carlin, Jeffrey L.; Liu, Chao; Newberg, Heidi Jo

    Here, we present a method to estimate distances to stars with spectroscopically derived stellar parameters. The technique is a Bayesian approach with likelihood estimated via comparison of measured parameters to a grid of stellar isochrones, and returns a posterior probability density function for each star's absolute magnitude. We tailor this technique specifically to data from the Large Sky Area Multi-object Fiber Spectroscopic Telescope (LAMOST) survey. Because LAMOST obtains roughly 3000 stellar spectra simultaneously within each ~5-degree diameter "plate" that is observed, we can use the stellar parameters of the observed stars to account for the stellar luminosity function and targetmore » selection effects. This removes biasing assumptions about the underlying populations, both due to predictions of the luminosity function from stellar evolution modeling, and from Galactic models of stellar populations along each line of sight. Using calibration data of stars with known distances and stellar parameters, we show that our method recovers distances for most stars within ~20%, but with some systematic overestimation of distances to halo giants. We apply our code to the LAMOST database, and show that the current precision of LAMOST stellar parameters permits measurements of distances with ~40% error bars. This precision should improve as the LAMOST data pipelines continue to be refined.« less

  8. Substrate comprising a nanometer-scale projection array

    DOEpatents

    Cui, Yi; Zhu, Jia; Hsu, Ching-Mei; Connor, Stephen T; Yu, Zongfu; Fan, Shanhui; Burkhard, George

    2012-11-27

    A method for forming a substrate comprising nanometer-scale pillars or cones that project from the surface of the substrate is disclosed. The method enables control over physical characteristics of the projections including diameter, sidewall angle, and tip shape. The method further enables control over the arrangement of the projections including characteristics such as center-to-center spacing and separation distance.

  9. 24 CFR 3280.611 - Vents and venting.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Size of vent piping—(1) Main vent. The drain piping for each toilet shall be vented by a 11/2 inch... venting cross section of a 11/2 inch diameter vent, connected to the toilet drain by one of the following... toilet drain within the distance allowed in § 3280.611(c)(5), for 3-inch trap arms undiminished in size...

  10. 24 CFR 3280.611 - Vents and venting.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Size of vent piping—(1) Main vent. The drain piping for each toilet shall be vented by a 11/2 inch... venting cross section of a 11/2 inch diameter vent, connected to the toilet drain by one of the following... toilet drain within the distance allowed in § 3280.611(c)(5), for 3-inch trap arms undiminished in size...

  11. Mode 1 stress intensity factors for round compact specimens

    NASA Technical Reports Server (NTRS)

    Gross, B.

    1976-01-01

    The mode 1 stress intensity factors were computed for round compact specimens by the boundary collocation method. Results are presented for ratios A sub T/R sub 0 in the range 0.3 to 0.8, where A sub t is the distance from the specimen center to the crack tip for a specimen of diameter 2R sub 0.

  12. Stand-Damage Model with Java (Version 3.0)

    Treesearch

    George Racin; J.J. Colbert

    2004-01-01

    NOTE: Instructions for ordering the cd-rom with the software are included on the front cover of the linked publication. The Stand-Damage Model with Java is a distance-independent tree-growth simulator. The model follows the life of a forest stand represented by species and diameter-class widths. The user supplies the initial state of the stand along with management...

  13. Large aperture segmented optics for space-to-ground communications.

    PubMed

    Lucy, R F

    1968-08-01

    A large aperture, moderate quality segmented optical array for use in noncoherent space-to-ground laser communications is determined as a function of resolution, diameter, focal length, and number of segments in the array. Secondary optics and construction tolerances are also discussed. Performance predictions show a typical receiver to be capable of megahertz communications at Mars distances during daylight operation.

  14. Pressure loss in elbow pipes of unplasticized polyvinyl chloride.

    PubMed

    Iwasaki, T; Ojima, J

    1996-01-01

    In the ductwork of local exhaust systems, 90 degrees elbow pipes (JIS K 6739) are commonly used to alter the direction of airflow; thus, are important components of polyvinyl chloride (PVC) ducts. Pressure loss in 90 degrees PVC elbow pipes was investigated by measuring static pressure, and the characteristics of airflow was determined. First, a linear decrease in static pressure was observed at points of the downstream side beyond a distance of 10 times the diameter (10d) from the flanged round opening of the smooth VU ducts (JIS K6741). The linear decrease was also observed at points of the downstream side located at distances of greater than 30d from the elbow pipe. Coefficients of loss in the PVC elbow pipes were found to be constant for the Reynolds numbers ranging from 3.38 x 10(4) to 5.96 x 10(5) for all diameters examined, and a chart of pressure loss was constructed with these coefficients. The coefficients of loss in PVC elbow pipes were not equivalent to those of metal stamped elbows for any R/d. However, the differences in the coefficients between the metal stamped elbow and the PVC elbow were smaller with larger R/d values.

  15. Ion wind generation and its application to drying of wild Ginger slices (Curcuma Xanthorhiza)

    NASA Astrophysics Data System (ADS)

    Sumariyah; Khuriati, Ainie; Fachriyah, Enny

    2018-05-01

    Temulawak or wild ginger is a herbal medicinal derived from lndonesia original. Wild ginger contains include an active compound as curcuminoid and antioxidant oleoresin components having a special quality to take care of health from various diseases. Drying is the important process to produce wild ginger (Curcuma xanthorrhiza) simplicia as raw material herbal medicine. In this study, has been dried of wild ginger using ion wind which yielded from corona discharge utilizing pin-multi ring concentred electrodes. Corona discharge was generated by using the fixed DC high voltage of 4,3 kV and drying was done at the distance between the fixed electrodes of 4 mm. Shaped of the five temulawak slices is a circle with a thickness of 2 mm and the diameter of 10 mm - 30 mm with 5 mm diameter interval. The sliced temulawak is placed just below the concentric multi-ring electrode and is 2 mm in distance. The wild ginger slices were dried with time varied 5-65 minutes with time interval 5 minutes. The researched result of drying of wild ginger slices obtained drying rate and shrinkage is inversely proportional to drying time.

  16. Investigation on the Mechanism and Failure Mode of Laser Transmission Spot Welding Using PMMA Material for the Automotive Industry

    PubMed Central

    Wang, Xiao; Liu, Baoguang; Liu, Wei; Zhong, Xuejiao; Jiang, Yingjie; Liu, Huixia

    2017-01-01

    To satisfy the need of polymer connection in lightweight automobiles, a study on laser transmission spot welding using polymethyl methacrylate (PMMA) is conducted by using an Nd:YAG pulse laser. The influence of three variables, namely peak voltages, defocusing distances and the welding type (type I (pulse frequency and the duration is 25 Hz, 0.6 s) and type II (pulse frequency and the duration is 5 Hz, 3 s)) to the welding quality was investigated. The result showed that, in the case of the same peak voltages and defocusing distances, the number of bubbles for type I was obviously more than type II. The failure mode of type I was the base plate fracture along the solder joint, and the connection strength of type I was greater than type II. The weld pool diameter:depth ratio for type I was significantly greater than type II. It could be seen that there was a certain relationship between the weld pool diameter:depth ratio and the welding strength. By the finite element simulation, the weld pool for type I was more slender than type II, which was approximately the same as the experimental results. PMID:28772383

  17. Guided-Mode-Leaky-Mode-Guided-Mode Fiber Interferometer and Its High Sensitivity Refractive Index Sensing Technology.

    PubMed

    Wang, Qi; Li, Chunyue; Zhao, Chengwu; Li, Weizheng

    2016-06-01

    A cascaded symmetrical dual-taper Mach-Zehnder interferometer structure based on guided-mode and leaky-mode interference is proposed in this paper. Firstly, the interference spectrum characteristics of interferometer has been analyzed by the Finite Difference-Beam Propagation Method (FD-BPM). When the diameter of taper waist is 20 μm-30 μm, dual-taper length is 1 mm and taper distance is 4 cm-6 cm, the spectral contrast is higher, which is suitable for sensing. Secondly, experimental research on refractive index sensitivity is carried out. A refractive index sensitivity of 62.78 nm/RIU (refractive index unit) can achieved in the RI range of 1.3333-1.3792 (0%~25% NaCl solution), when the sensor structure parameters meet the following conditions: diameter of taper waist is 24 μm, dual-taper length is 837 μm and taper distance is 5.5 cm. The spectrum contrast is 0.8 and measurement resolution is 1.6 × 10(-5) RIU. The simulation analysis is highly consistent with experimental results. Research shows that the sensor has promising application in low RI fields where high-precision measurement is required due to its high sensitivity and stability.

  18. Influence of elliptical structure on impinging-jet-array heat transfer performances

    NASA Astrophysics Data System (ADS)

    Arjocu, Simona C.; Liburdy, James A.

    1997-11-01

    A three-by-three square array of submerged, elliptic, impinging jets in water was used to study the heat transfer distribution in the cooling process of a constant heat flux surface. Tow jet aspect ratios were used, 2 and 3, both with the same hydraulic diameter. The array was tested at Reynolds numbers from 300 to 1500 and impinging distances of 1 to 5 hydraulic diameters. Thermochromic liquid crystals wee used to map the local heat transfer coefficient using a transient method, while the jet temperature was kept constant. The liquid crystal images were recorded through an optical fiber coupled with a CCD camera and a frame grabber and analyzed based on an RGB-temperature calibration technique. The results are reported relative to the unit cell that is used to delimitate the central jet. The heat transfer variation is shown to depend on the impingement distance and Reynolds number. The elliptic jets exhibit axis switching, jet column instability and jet swaying. All of these mechanisms affect the enhancement of the heat transfer rate and its distribution. The results are compared in terms of average and local heat transfer coefficients, for both major and minor planes for the two jet aspect ratios.

  19. Shock interaction behind a pair of cylindrical obstacles

    NASA Astrophysics Data System (ADS)

    Liu, Heng; Mazumdar, Raoul; Eliasson, Veronica

    2014-11-01

    The body of work focuses on two-dimensional numerical simulations of shock interaction with a pair of cylindrical obstacles, varying the obstacle separation and incident shock strength. With the shock waves propagating parallel to the center-line between the two cylindrical obstacles, the shock strengths simulated vary from a Mach of 1.4 to a Mach of 2.4, against a wide range of obstacle separation distance to their diameters. These cases are simulated via a software package called Overture, which is used to solve the inviscid Euler equations of gas dynamics on overlapping grids with adaptive mesh refinement. The goal of these cases is to find a so-called ``safe'' region for obstacle spacing and varying shock Mach numbers, such that the pressure in the ``safe'' region is reduced downstream of the obstacles. The benefits apply to both building and armor design for the purpose of shock wave mitigation to keep humans and equipment safe. The results obtained from the simulations confirm that the length of the ``safe'' region and the degree of shock wave attenuation depend on the ratio of obstacle separation distance to obstacle diameter. The influence of various Mach number is also discussed.

  20. Investigation on the Mechanism and Failure Mode of Laser Transmission Spot Welding Using PMMA Material for the Automotive Industry.

    PubMed

    Wang, Xiao; Liu, Baoguang; Liu, Wei; Zhong, Xuejiao; Jiang, Yingjie; Liu, Huixia

    2017-01-01

    To satisfy the need of polymer connection in lightweight automobiles, a study on laser transmission spot welding using polymethyl methacrylate (PMMA) is conducted by using an Nd:YAG pulse laser. The influence of three variables, namely peak voltages, defocusing distances and the welding type (type I (pulse frequency and the duration is 25 Hz, 0.6 s) and type II (pulse frequency and the duration is 5 Hz, 3 s)) to the welding quality was investigated. The result showed that, in the case of the same peak voltages and defocusing distances, the number of bubbles for type I was obviously more than type II. The failure mode of type I was the base plate fracture along the solder joint, and the connection strength of type I was greater than type II. The weld pool diameter:depth ratio for type I was significantly greater than type II. It could be seen that there was a certain relationship between the weld pool diameter:depth ratio and the welding strength. By the finite element simulation, the weld pool for type I was more slender than type II, which was approximately the same as the experimental results.

  1. Characterization of self-assembled virus-like particles of dromedary camel hepatitis e virus generated by recombinant baculoviruses.

    PubMed

    Zhou, Xianfeng; Kataoka, Michiyo; Liu, Zheng; Takeda, Naokazu; Wakita, Takaji; Li, Tian-Cheng

    2015-12-02

    Dromedary camel hepatitis E virus (DcHEV), a novel hepatitis E virus, has been identified in dromedary camels in Dubai, United Arab Emirates. The antigenicity, pathogenicity and epidemiology of this virus have been unclear. Here we first used a recombinant baculovirus expression system to express the 13 and 111 N-terminus amino-acid-truncated DcHEV ORF2 protein in insect Tn5 cells, and we obtained two types of virus-like particles (VLPs) with densities of 1.300 g/cm(3) and 1.285 g/cm(3), respectively. The small VLPs (Dc4sVLPs) were estimated to be 24 nm in diameter, and were assembled by a protein with the molecular mass 53 kDa. The large VLPs (Dc3nVLPs and Dc4nVLPs) were 35 nm in diameter, and were assembled by a 64-kDa protein. An antigenic analysis demonstrated that DcHEV was cross-reactive with G1, G3-G6, ferret and rat HEVs, and DcHEV showed a stronger cross-reactivity to G1 G3-G6 HEV than it did to rat and ferret HEV. In addition, the antibody against DcHEV-LPs neutralized G1 and G3 HEV in a cell culture system, suggesting that the serotypes of these HEVs are identical. We also found that the amino acid residue Met-358 affects the small DcHEV-LPs assembly. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Respiratory Displacement of the Thoracic Aorta: Physiological Phenomenon With Potential Implications for Thoracic Endovascular Repair

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Weber, Tim Frederik, E-mail: tim.weber@med.uni-heidelberg.d; Tetzlaff, Ralf; Rengier, Fabian

    The purpose of this study was to assess the magnitude and direction of respiratory displacement of the ascending and descending thoracic aorta during breathing maneuvers. In 11 healthy nonsmokers, dynamic magnetic resonance imaging was performed in transverse orientation at the tracheal bifurcation during maximum expiration and inspiration as well as tidal breathing. The magnitude and direction of aortic displacement was determined relatively to resting respiratory position for the ascending (AA) and descending (DA) aorta. To estimate a respiratory threshold for occurrence of distinct respiratory aortic motion, the latter was related to the underlying change in anterior-posterior thorax diameter. Compound displacementmore » between maximum expiration and inspiration was 24.3 {+-} 6.0 mm for the AA in the left anterior direction and 18.2 {+-} 5.5 mm for the DA in the right anterior direction. The mean respiratory thorax excursion during tidal breathing was 8.9 {+-} 2.8 mm. The respiratory threshold, i.e., the increase in thorax diameter necessary to result in respiratory aortic displacement, was estimated to be 15.7 mm. The data suggest that after a threshold of respiratory thorax excursion is exceeded, respiration is accompanied by significant displacement of the thoracic aorta. Although this threshold may not be reached during tidal breathing in the majority of individuals, segmental differences during forced respiration impact on aortic geometry, may result in additional extrinsic forces on the aortic wall, and may be of significance for aortic prostheses designed for thoracic endovascular aortic repair.« less

  3. A BAYESIAN APPROACH TO DERIVING AGES OF INDIVIDUAL FIELD WHITE DWARFS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    O'Malley, Erin M.; Von Hippel, Ted; Van Dyk, David A., E-mail: ted.vonhippel@erau.edu, E-mail: dvandyke@imperial.ac.uk

    2013-09-20

    We apply a self-consistent and robust Bayesian statistical approach to determine the ages, distances, and zero-age main sequence (ZAMS) masses of 28 field DA white dwarfs (WDs) with ages of approximately 4-8 Gyr. Our technique requires only quality optical and near-infrared photometry to derive ages with <15% uncertainties, generally with little sensitivity to our choice of modern initial-final mass relation. We find that age, distance, and ZAMS mass are correlated in a manner that is too complex to be captured by traditional error propagation techniques. We further find that the posterior distributions of age are often asymmetric, indicating that themore » standard approach to deriving WD ages can yield misleading results.« less

  4. Distal Ureteral Diameter Ratio is Predictive of Breakthrough Febrile Urinary Tract Infection.

    PubMed

    Arlen, Angela M; Leong, Traci; Guidos, P Joseph; Alexander, Siobhan E; Cooper, Christopher S

    2017-12-01

    Distal ureteral diameter ratio is an objective measure that is prognostic of spontaneous resolution of vesicoureteral reflux. Along with likelihood of resolution, improved identification of children at risk for recurrent febrile urinary tract infections may impact management decisions. We evaluated the usefulness of ureteral diameter ratio as a predictive factor for breakthrough febrile urinary tract infections. Children with primary vesicoureteral reflux and detailed voiding cystourethrogram were identified. Ureteral diameter ratio was computed by measuring largest ureteral diameter within the pelvis and dividing by the distance between L1 and L3 vertebral bodies. Demographics, vesicoureteral reflux grade, laterality, presence/absence of bladder-bowel dysfunction, and ureteral diameter ratio were tested in univariate and multivariable analyses. Primary outcome was breakthrough febrile urinary tract infections. We analyzed 112 girls and 28 boys with a mean ± SD age of 2.5 ± 2.3 years at diagnosis. Vesicoureteral reflux was grade 1 to 2 in 64 patients (45.7%), grade 3 in 50 (35.7%), grade 4 in 16 (11.4%) and grade 5 in 10 (7.2%). Mean ± SD followup was 3.2 ± 2.7 years. A total of 40 children (28.6%) experienced breakthrough febrile urinary tract infections. Ureteral diameter ratio was significantly greater in children with (0.36) vs without (0.25) breakthrough febrile infections (p = 0.004). Controlling for vesicoureteral reflux grade, every 0.1 U increase in ureteral diameter ratio resulted in 1.7 times increased odds of breakthrough infection (95% CI 1.24 to 2.26, p <0.0001). Children with increased distal ureteral diameter ratio are at greater risk for breakthrough febrile urinary tract infections independent of reflux grade. Ureteral diameter ratio provides valuable prognostic information about risk of recurrent pyelonephritis and may assist with clinical decision-making. Copyright © 2017 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Dendrimer-assisted patch-clamp sizing of nuclear pores

    PubMed Central

    Bustamante, J.O.; Michelette, E.R.F.; Geibel, J.P.; Hanover, J.A.; McDonnell, T.J.; Dean, D.A.

    2015-01-01

    Macromolecular translocation (MMT) across the nuclear envelope (NE) occurs exclusively through the nuclear pore complex (NPC). Therefore, the diameter of the NPC aqueous/electrolytic channel (NPCC) is important for cellular structure and function. The NPCC diameter was previously determined to be ≅10 nm with electron microscopy (EM) using the translocation of colloidal gold particles. Here we present patch-clamp and fluorescence microscopy data from adult cardiomyocyte nuclei that demonstrate the use of patch-clamp for assessing NPCC diameter. Fluorescence microscopy with B-phycoerythrin (BPE, 240 kDa) conjugated to a nuclear localization signal (NLS) demonstrated that these nuclei were competent for NPC-mediated MMT (NPC-MMT). Furthermore, when exposed to an appropriate cell lysate, the nuclei expressed enhanced green fluorescence protein (EGFP) after 5–10 h of incubation with the plasmid for this protein (pEGFP, 3.1 MDa). Nucleus-attached patch-clamp showed that colloidal gold particles were not useful probes; they modified NPCC gating. As a result of this finding, we searched for an inert class of particles that could be used without irreversibly affecting NPCC gating and found that fluorescently labeled Star-burst dendrimers, a distinct class of polymers, were useful. Our patch-clamp and fluorescence microscopy data with calibrated dendrimers indicate that the cardiomyocyte NPCC diameter varies between 8 and 9 nm. These studies open a new direction in the investigation of live, continuous NPC dynamics under physiological conditions. PMID:10784359

  6. Plane Symmetric Dark Energy Models in the Form of Wet Dark Fluid in f ( R, T) Gravity

    NASA Astrophysics Data System (ADS)

    Chirde, V. R.; Shekh, S. H.

    2016-06-01

    In this paper, we have investigated the plane symmetric space-time with wet dark fluid (WDF), which is a candidate for dark energy, in the framework of f ( R, T) gravity Harko et al. 2011, Phys. Rev. D, 84, 024020), where R and T denote the Ricci scalar and the trace of the energy-momentum tensor respectively. We have used the equation of state in the form of WDF for the dark energy component of the Universe. It is modeled on the equation of state p = ω( ρ - ρ ∗). The exact solutions to the corresponding field equations are obtained for power-law and exponential volumetric expansion. The geometrical and physical parameters for both the models are studied. Also, we have discussed the well-known astrophysical phenomena, namely the look-back time, proper distance, the luminosity distance and angular diameter distance with red shift.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Menikoff, Ralph

    SURFplus is a reactive burn model for high explosives aimed at modelling shock initiation and propagation of detonation waves. It utilizes the SURF model for the fast hot-spot reaction plus a slow reaction for the energy released by carbon clustering. A feature of the SURF model is that there is a partially decoupling between burn rate parameters and detonation wave properties. Previously, parameters for PBX 9502 that control shock ini- tiation had been calibrated to Pop plot data (distance-of-run to detonation as a function of shock pressure initiating the detonation). Here burn rate parameters for the high pres- sure regimemore » are adjusted to t the failure diameter and the limiting detonation speed just above the failure diameter. Simulated results are shown for an uncon ned rate stick when the 9502 diameter is slightly above and slightly below the failure diameter. Just above the failure diameter, in the rest frame of the detonation wave, the front is sonic at the PBX/air interface. As a consequence, the lead shock in the neighborhood of the interface is supported by the detonation pressure in the interior of the explosive rather than the reaction immediately behind the front. In the interior, the sonic point occurs near the end of the fast hot-spot reaction. Consequently, the slow carbon clustering reaction can not a ect the failure diameter. Below the failure diameter, the radial extent of the detonation front decreases starting from the PBX/air interface. That is, the failure starts at the PBX boundary and propagates inward to the axis of the rate stick.« less

  8. Morphometric analysis of torso arterial anatomy with implications for resuscitative aortic occlusion.

    PubMed

    Stannard, Adam; Morrison, Jonathan J; Sharon, Danny J; Eliason, Jonathan L; Rasmussen, Todd E

    2013-08-01

    Hemorrhage is a leading cause of death in military and civilian trauma. Despite the importance of the aorta as a site of hemorrhage control and resuscitative occlusion, detailed knowledge of its morphometry is lacking. The objective of this study was to characterize aortic morphometry in a trauma population, including quantification of distances as well as and diameters and definition of relevant aortic zones. Center line measures were made (Volume Viewer) from contrast computed tomography (CT) scans of male trauma patients (18-45 years). Aortic zones were defined based on branch arteries. Zone I includes left subclavian to celiac; Zone II includes celiac to caudal renal; Zone III includes caudal renal to aortic bifurcation. Zone lengths were calculated and correlated to a novel external measure of torso extent (symphysis pubis to sternal notch). Eighty-eight males (mean [SD], 28 [4] years) had CT scans for the study. The median (interquartile range) lengths (mm) of Zones I, II, and III were 210 mm (202-223 mm), 33 mm (28-38 mm), and 97 mm (91-103 mm), respectively. Median aortic diameters at the left subclavian, celiac, and lowest renal arteries were 21 mm (20-23 mm), 18 mm (16-19 mm), and 15 mm (14-16 mm), respectively, and the terminal aortic diameter was 14 mm (13-15 mm). The correlation of determination for descending aortic length (all zones) against torso extend was r = 0.454. This study provides a morphometric analysis of the aorta in a male population, demonstrating consistency of length and diameter while defining distinct axial zones. Findings suggest that center line aortic distances correlate with a simple, external measure of torso extent. Morphometric study of the aorta using CT data may facilitate the development and implementation of occlusion techniques to manage noncompressible torso, pelvic, and junctional femoral hemorrhage.

  9. Normal renal arterial anatomy assessed by multidetector CT angiography: are there differences between men and women?

    PubMed

    Turba, Ulku Cenk; Uflacker, Renan; Bozlar, Ugur; Hagspiel, Klaus D

    2009-03-01

    The purpose of this study was to determine renal arterial anatomy and gender differences in adults without renovascular disease using multidetector computed tomography angiography (MDCTA). MDCTA datasets of 399 patients were retrospectively reviewed. Measurements of the aortorenal diameters, the angulation of the renal ostia and pedicles as well as the distance between the origins of the renal arteries were measured. Differences in measurements between genders were tested for statistical significance using analysis of variance (ANOVA) and Pearson's Chi-Square tests. A total of 798 renal arteries were available for analysis in 207 female (mean age = 52.91 years) and 192 male patients (mean age = 53.04 years). Female patients were found to have smaller aortae (at the level of the right renal ostium) and bilateral renal arteries than males (mean aortic diameter M/F = 18.33/15.89 mm, mean right renal artery ostial diameter M/F = 5.06/4.59 mm, mean left ostial renal diameter M/F = 5.14/4.66 mm) (p < .001). There was no statistical significance for the renal ostia level in relation to the vertebrae and the majority of renal arteries originated at the L1 and L2 levels. The longitudinal distance between right and left renal artery ostia ranged from 0 to 32 mm (mean = 4,6 mm, median = 5mm). The mean anteroposterior orientation of the right renal ostia was M/F = 29.45 degrees/28.20 degrees , and M/F = -7.96 degrees/-11.14 degrees for left renal artery ostia. The mean anteroposterior orientation of the right renal pedicle was M/F = 41.37 degrees/44.34 degrees and M/F = 42.31 degrees/43.95 degrees for the left pedicle. There are some differences in normal renal arterial anatomy between genders. Normal renal arterial information is useful not only for planning and performing of endovascular and laparoscopic urologic procedures, but also for medical device development. Copyright 2009 Wiley-Liss, Inc.

  10. A micro-computed tomographic study of band-shaped root canal isthmuses, having their floor in the apical third of mesial roots of mandibular first molars.

    PubMed

    Keleş, A; Keskin, C

    2018-02-01

    To conduct a quantitative and qualitative analysis of the band-shaped isthmus area, the floor of which was in the apical third in the mesial roots of mandibular first molars using micro-computed tomography (micro-CT). Micro-CT images of 269 mesial roots of mandibular first molars were evaluated, and 40 specimens with a band-shaped isthmus, with a floor in the apical third, were selected. The major diameter, minor diameter, roundness, area and perimeter values for the most coronal and apical slices where the isthmus was visible were measured. The distances between these slices were measured as the isthmus length, and the total volume, structure model index and surface area of the isthmus were measured. The distances between the isthmus floor and two apical foramina and the number of root canal orifices were calculated. The dimensions of the isthmus roof and the floor were compared, and the data were analysed using descriptive statistics and Student's t-tests with a significance threshold set at 5%. A total of 15% of the specimens had band-shaped isthmuses with a floor in the apical third. The isthmus roof exhibited significantly greater major and minor diameter values compared to the isthmus floor (P < 0.05). No significant difference was detected between the isthmus roof and the floor with regard to roundness (P > 0.05). Three- and two-dimensional analyses of the mesial roots of mandibular molars revealed that band-shaped isthmuses had complex shapes. © 2017 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  11. Preparation and characterization of supported magnetic nanoparticles prepared by reverse micelles

    PubMed Central

    Han, Luyang; Biskupek, Johannes; Kaiser, Ute; Ziemann, Paul

    2010-01-01

    Summary Monatomic (Fe, Co) and bimetallic (FePt and CoPt) nanoparticles were prepared by exploiting the self-organization of precursor loaded reverse micelles. Achievements and limitations of the preparation approach are critically discussed. We show that self-assembled metallic nanoparticles can be prepared with diameters d = 2–12 nm and interparticle distances D = 20–140 nm on various substrates. Structural, electronic and magnetic properties of the particle arrays were characterized by several techniques to give a comprehensive view of the high quality of the method. For Co nanoparticles, it is demonstrated that magnetostatic interactions can be neglected for distances which are at least 6 times larger than the particle diameter. Focus is placed on FePt alloy nanoparticles which show a huge magnetic anisotropy in the L10 phase, however, this is still less by a factor of 3–4 when compared to the anisotropy of the bulk counterpart. A similar observation was also found for CoPt nanoparticles (NPs). These results are related to imperfect crystal structures as revealed by HRTEM as well as to compositional distributions of the prepared particles. Interestingly, the results demonstrate that the averaged effective magnetic anisotropy of FePt nanoparticles does not strongly depend on size. Consequently, magnetization stability should scale linearly with the volume of the NPs and give rise to a critical value for stability at ambient temperature. Indeed, for diameters above 6 nm such stability is observed for the current FePt and CoPt NPs. Finally, the long-term conservation of nanoparticles by Au photoseeding is presented. PMID:21977392

  12. Performance and wake conditions of a rotor located in the wake of an obstacle

    NASA Astrophysics Data System (ADS)

    Naumov, I. V.; Kabardin, I. K.; Mikkelsen, R. F.; Okulov, V. L.; Sørensen, J. N.

    2016-09-01

    Obstacles like forests, ridges and hills can strongly affect the velocity profile in front of a wind turbine rotor. The present work aims at quantifying the influence of nearby located obstacles on the performance and wake characteristics of a downstream located wind turbine. Here the influence of an obstacle in the form of a cylindrical disk was investigated experimentally in a water flume. A model of a three-bladed rotor, designed using Glauert's optimum theory at a tip speed ratio λ = 5, was placed in the wake of a disk with a diameter close to the one of the rotor. The distance from the disk to the rotor was changed from 4 to 8 rotor diameters, with the vertical distance from the rotor axis varied 0.5 and 1 rotor diameters. The associated turbulent intensity of the incoming flow to the rotor changed 3 to '6% due to the influence of the disk wake. In the experiment, thrust characteristics and associated pulsations as a function of the incoming flow structures were measured by strain gauges. The flow condition in front of the rotor was measured with high temporal accuracy using LDA and power coefficients were determine as function of tip speed ratio for different obstacle positions. Furthermore, PIV measurements were carried out to study the development of the mean velocity deficit profiles of the wake behind the wind turbine model under the influence of the wake generated by the obstacle. By use of regression techniques to fit the velocity profiles it was possible to determine velocity deficits and estimate length scales of the wake attenuation.

  13. VizieR Online Data Catalog: WDMS from LAMOST DR1 (Ren+, 2014)

    NASA Astrophysics Data System (ADS)

    Ren, J. J.; Rebassa-Mansergas, A.; Luo, A. L.; Zhao, Y. H.; Xiang, M. S.; Liu, X. W.; Zhao, G.; Jin, G.; Zhang, Y.

    2014-08-01

    The ascii data of all LAMOST DR1 DA/M binary spectra are presented. The complete table of stellar parameters, magnitudes, radial velocities of the LAMOST DA/M binaries are also provided. The stellar parameters table includes the white dwarf stellar parameters (effective temperature, surface gravity and mass), spectral type of the companions and distance when available, however only those with a S/N higher 12 (second column) are considered in the analysis of the paper. Spectral types of -1 imply that no values are available. For completeness, the table also include 181 systems that are not considered by us as DA/M binaries but that show blue and red components in their spectra. These are flagged as 1 in the last column. The magnitudes table includes the SDSS or Xuyi magnitudes (when available) and coordinates. The radial velocities includes the NaI 8183.27,8194.81 absorption doublet and Halpha emission radial velocities and errors, as well as the Heliocentric Julian dates and the telescope used for obtaining the spectra (either LAMOST or SDSS). (4 data files).

  14. Structure of the 30 kDa HIV-1 RNA Dimerization Signal by a Hybrid Cryo-EM, NMR, and Molecular Dynamics Approach.

    PubMed

    Zhang, Kaiming; Keane, Sarah C; Su, Zhaoming; Irobalieva, Rossitza N; Chen, Muyuan; Van, Verna; Sciandra, Carly A; Marchant, Jan; Heng, Xiao; Schmid, Michael F; Case, David A; Ludtke, Steven J; Summers, Michael F; Chiu, Wah

    2018-03-06

    Cryoelectron microscopy (cryo-EM) and nuclear magnetic resonance (NMR) spectroscopy are routinely used to determine structures of macromolecules with molecular weights over 65 and under 25 kDa, respectively. We combined these techniques to study a 30 kDa HIV-1 dimer initiation site RNA ([DIS] 2 ; 47 nt/strand). A 9 Å cryo-EM map clearly shows major groove features of the double helix and a right-handed superhelical twist. Simulated cryo-EM maps generated from time-averaged molecular dynamics trajectories (10 ns) exhibited levels of detail similar to those in the experimental maps, suggesting internal structural flexibility limits the cryo-EM resolution. Simultaneous inclusion of the cryo-EM map and 2 H-edited NMR-derived distance restraints during structure refinement generates a structure consistent with both datasets and supporting a flipped-out base within a conserved purine-rich bulge. Our findings demonstrate the power of combining global and local structural information from these techniques for structure determination of modest-sized RNAs. Copyright © 2018 Elsevier Ltd. All rights reserved.

  15. The uncatchable smile in Leonardo da Vinci's La Bella Principessa portrait.

    PubMed

    Soranzo, Alessandro; Newberry, Michelle

    2015-08-01

    A portrait of uncertain origin recently came to light which, after extensive research and examination, was shown to be that rarest of things: a newly discovered Leonardo da Vinci painting entitled La Bella Principessa. This research presents a new illusion which is similar to that identified in the Mona Lisa; La Bella Principessa's mouth appears to change slant depending on both the Viewing Distance and the Level of Blur applied to a digital version of the portrait. Through a series of psychophysics experiments, it was found that a perceived change in the slant of the La Bella Principessa's mouth influences her expression of contentment thus generating an illusion that we have coined the "uncatchable smile". The elusive quality of the Mona Lisa's smile has been previously reported (Science, 290 (2000) 1299) and so the existence of a similar illusion in a portrait painted prior to the Mona Lisa becomes more interesting. The question remains whether Leonardo da Vinci intended this illusion. In any case, it can be argued that the ambiguity created adds to the portrait's allure. Copyright © 2015 Elsevier Ltd. All rights reserved.

  16. Hydrodynamic interaction of trapped active Janus particles in two dimensions

    NASA Astrophysics Data System (ADS)

    Debnath, Tanwi; Li, Yunyun; Ghosh, Pulak K.; Marchesoni, Fabio

    2018-04-01

    The dynamics of a pair of identical artificial microswimmers bound inside two harmonic traps, in a thin sheared fluid film, is numerically investigated. In a two-dimensional Oseen approximation, the hydrodynamic pair coupling is long-ranged and proportional to the particle radius to film thickness ratio. On increasing such ratio above a certain threshold, a transition occurs between a free regime, where each swimmer orbits in its own trap with random phase, and a strong synchronization regime, where the two swimmers strongly repel each other to an average distance larger than both the trap distance and their free orbit diameter. Moreover, the swimmers tend to synchronize their positions opposite the center of the system.

  17. Transparent nanocrystalline diamond coatings and devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sumant, Anirudha V.; Khan, Adam

    2017-08-22

    A method for coating a substrate comprises producing a plasma ball using a microwave plasma source in the presence of a mixture of gases. The plasma ball has a diameter. The plasma ball is disposed at a first distance from the substrate and the substrate is maintained at a first temperature. The plasma ball is maintained at the first distance from the substrate, and a diamond coating is deposited on the substrate. The diamond coating has a thickness. Furthermore, the diamond coating has an optical transparency of greater than about 80%. The diamond coating can include nanocrystalline diamond. The microwavemore » plasma source can have a frequency of about 915 MHz.« less

  18. Functionalized nanoparticle interactions with polymeric membranes

    PubMed Central

    Ladner, D.A.; Steele, M.; Weir, A.; Hristovski, K.; Westerhoff, P.

    2011-01-01

    A series of experiments was performed to measure the retention of a class of functionalized nanoparticles (NPs) onporous (microfiltration and ultrafiltration) membranes. The findings impact engineered water and wastewater treatment using membrane technology, characterization and analytical schemes for NP detection, and the use of NPs in waste treatment scenarios. The NPs studied were composed of silver, titanium dioxide, and gold; had organic coatings to yield either positive or negative surface charge; and were between 2 and 10 nm in diameter. NP solutions were applied to polymeric membranes composed of different materials and pore sizes (ranging from ~2 nm [3 kDa molecular weight cutoff] to 0.2 μm). Greater than 99% rejection was observed of positively charged NPs by negatively charged membranes even though pore diameters were up to 20 times the NP diameter; thus, sorption caused rejection. Negatively charged NPs were less well rejected, but behavior was dependant not only on surface functionality but on NP core material (Ag, TiO2, or Au). NP rejection depended more upon NP properties than membrane properties; all of the negatively charged polymeric membranes behaved similarly. The NP-membrane interaction behavior fell into four categories, which are defined and described here. PMID:22177020

  19. Automatic localization of the da Vinci surgical instrument tips in 3-D transrectal ultrasound.

    PubMed

    Mohareri, Omid; Ramezani, Mahdi; Adebar, Troy K; Abolmaesumi, Purang; Salcudean, Septimiu E

    2013-09-01

    Robot-assisted laparoscopic radical prostatectomy (RALRP) using the da Vinci surgical system is the current state-of-the-art treatment option for clinically confined prostate cancer. Given the limited field of view of the surgical site in RALRP, several groups have proposed the integration of transrectal ultrasound (TRUS) imaging in the surgical workflow to assist with accurate resection of the prostate and the sparing of the neurovascular bundles (NVBs). We previously introduced a robotic TRUS manipulator and a method for automatically tracking da Vinci surgical instruments with the TRUS imaging plane, in order to facilitate the integration of intraoperative TRUS in RALRP. Rapid and automatic registration of the kinematic frames of the da Vinci surgical system and the robotic TRUS probe manipulator is a critical component of the instrument tracking system. In this paper, we propose a fully automatic registration technique based on automatic 3-D TRUS localization of robot instrument tips pressed against the air-tissue boundary anterior to the prostate. The detection approach uses a multiscale filtering technique to identify and localize surgical instrument tips in the TRUS volume, and could also be used to detect other surface fiducials in 3-D ultrasound. Experiments have been performed using a tissue phantom and two ex vivo tissue samples to show the feasibility of the proposed methods. Also, an initial in vivo evaluation of the system has been carried out on a live anaesthetized dog with a da Vinci Si surgical system and a target registration error (defined as the root mean square distance of corresponding points after registration) of 2.68 mm has been achieved. Results show this method's accuracy and consistency for automatic registration of TRUS images to the da Vinci surgical system.

  20. Methamphetamine potentiates behavioral and electrochemical responses after mild traumatic brain injury in mice.

    PubMed

    Shen, Hui; Harvey, Brandon K; Chiang, Yung-Hsiao; Pick, Chaim G; Wang, Yun

    2011-01-12

    We previously demonstrated that high doses of methamphetamine (MA) exacerbate damage induced by severe brain trauma. The purpose of the present study was to examine if MA, at low dosage, affected abnormalities in locomotor activity and dopamine turnover in a mouse model of mild traumatic brain injury (mTBI). Adult male CD1 mice were treated with MA (5 mg/kgi.p.) or vehicle 30-min prior to mTBI, conducted by dropping a 30 g metal weight onto the temporal skull, anterior the right ear. At 15 min after mTBI, animals were put into locomotor activity chambers for up to 72 h. During the first 3 h, mTBI alone, compared with vehicle control, did not alter total distance travelled. Treatment with MA significantly increased locomotor activity in the control animals during the first 3 h; mTBI reduced MA-induced hyperactivity. In contrast, at 2 and 3 days after injury, mTBI or MA alone reduced locomotor activity. Co-treatment with MA and mTBI further reduced this activity, suggesting a differential and temporal behavioral interaction between MA and mTBI during acute and subacute phases after injury. Dopamine and DOPAC levels in striatal tissue were analyzed using HPLC-ECD. At 1h after mTBI or injection, DA was not altered but DOPAC level and DOPAC/DA turnover ratios were significantly reduced. Co-treatment with MA further reduced the DOPAC/DA ratio. At 36 h after injury, mTBI increased tissue DA levels, but reduced DOPAC levels and DOPAC/DA ratios. Co-treatment with MA further reduced DOPAC/DA ratios in striatum. In conclusion, our data suggest that low dosage of MA worsens the suppression of locomotor responses and striatal dopamine turnover after mTBI. Published by Elsevier B.V.

  1. Differential expression of stress proteins in rat myocardium after free wheel or treadmill run training.

    PubMed

    Noble, E G; Moraska, A; Mazzeo, R S; Roth, D A; Olsson, M C; Moore, R L; Fleshner, M

    1999-05-01

    High-intensity treadmill exercise increases the expression of a cardioprotective, inducible 72-kDa stress protein (SP72) in cardiac muscle. This investigation examined whether voluntary free wheel exercise training would be sufficient to confer a similar response. Male Sprague-Dawley rats were randomly assigned to either treadmill (TM-Tr) or free wheel (FW-Tr) training groups. By the end of the 8-wk training period, TM-Tr animals ran 1 h/day, 5 days/wk up a 10% grade, covering a distance of 8,282 m/wk. FW-Tr rats ran, on average, 5,300 m/wk, with one-third of the animals covering distances similar to those for the TM-Tr group. At the time of death, hearts of trained and caged sedentary control (Sed) animals were divided into left (LV) and right (RV) ventricles. Citrate synthase activity and the relative immunoblot contents of SP72, SP73 (the constitutive isoform of the SP70 family), and a 75-kDa mitochondrial chaperone (SP75) were subsequently determined. LV and RV did not differ on any measure, and SP73, SP75, and citrate synthase were not affected by training. Cardiac SP72 levels were elevated over fourfold in both ventricles of TM-Tr compared with RV of FW-Sed rats. Despite the animals having run a similar total distance, cardiac SP72 content in FW-Tr rats was not different from that in Sed animals. These data indicate that voluntary exercise training is insufficient to elicit an elevation of SP72 in rat heart and suggest that exercise intensity may be a critical factor in evoking the cardioprotective SP72 response.

  2. Bone-Induced Chondroinduction in Sheep Jamshidi Biopsy Defects with and without Treatment by Subchondral Chitosan-Blood Implant: 1-Day, 3-Week, and 3-Month Repair.

    PubMed

    Bell, Angela D; Lascau-Coman, Viorica; Sun, Jun; Chen, Gaoping; Lowerison, Mark W; Hurtig, Mark B; Hoemann, Caroline D

    2013-04-01

    Delivery of chitosan to subchondral bone is a novel approach for augmented marrow stimulation. We evaluated the effect of 3 presolidified chitosan-blood implant formulations on osteochondral repair progression compared with untreated defects. In N = 5 adult sheep, six 2-mm diameter Jamshidi biopsy holes were created bilaterally in the medial femoral condyle and treated with presolidified chitosan-blood implant with fluorescent chitosan tracer (10 kDa, 40 kDa, or 150k Da chitosan, left knee) or left to bleed (untreated, right knee). Implant residency and osteochondral repair were assessed at 1 day (N = 1), 3 weeks (N = 2), or 3 months (N = 2) postoperative using fluorescence microscopy, histomorphometry, stereology, and micro-computed tomography. Chitosan implants were retained in 89% of treated Jamshidi holes up to 3 weeks postoperative. At 3 weeks, biopsy sites were variably covered by cartilage flow, and most bone holes contained cartilage flow fragments and heterogeneous granulation tissues with sparse leukocytes, stromal cells, and occasional adipocytes (volume density 1% to 3%). After 3 months of repair, most Jamshidi bone holes were deeper, remodeling at the edges, filled with angiogenic granulation tissue, and lined with variably sized chondrogenic foci fused to bone trabeculae or actively repairing bone plate. The 150-kDa chitosan implant elicited more subchondral cartilage formation compared with 40-kDa chitosan-treated and control defects (P < 0.05, N = 4). Treated defects contained more mineralized repair tissue than control defects at 3 months (P < 0.05, N = 12). Bone plate-induced chondroinduction is an articular cartilage repair mechanism. Jamshidi biopsy repair takes longer than 3 months and can be influenced by subchondral chitosan-blood implant.

  3. Bone-Induced Chondroinduction in Sheep Jamshidi Biopsy Defects with and without Treatment by Subchondral Chitosan-Blood Implant

    PubMed Central

    Bell, Angela D.; Lascau-Coman, Viorica; Sun, Jun; Chen, Gaoping; Lowerison, Mark W.; Hurtig, Mark B.

    2013-01-01

    Objective: Delivery of chitosan to subchondral bone is a novel approach for augmented marrow stimulation. We evaluated the effect of 3 presolidified chitosan-blood implant formulations on osteochondral repair progression compared with untreated defects. Design: In N = 5 adult sheep, six 2-mm diameter Jamshidi biopsy holes were created bilaterally in the medial femoral condyle and treated with presolidified chitosan-blood implant with fluorescent chitosan tracer (10 kDa, 40 kDa, or 150k Da chitosan, left knee) or left to bleed (untreated, right knee). Implant residency and osteochondral repair were assessed at 1 day (N = 1), 3 weeks (N = 2), or 3 months (N = 2) postoperative using fluorescence microscopy, histomorphometry, stereology, and micro–computed tomography. Results: Chitosan implants were retained in 89% of treated Jamshidi holes up to 3 weeks postoperative. At 3 weeks, biopsy sites were variably covered by cartilage flow, and most bone holes contained cartilage flow fragments and heterogeneous granulation tissues with sparse leukocytes, stromal cells, and occasional adipocytes (volume density 1% to 3%). After 3 months of repair, most Jamshidi bone holes were deeper, remodeling at the edges, filled with angiogenic granulation tissue, and lined with variably sized chondrogenic foci fused to bone trabeculae or actively repairing bone plate. The 150-kDa chitosan implant elicited more subchondral cartilage formation compared with 40-kDa chitosan-treated and control defects (P < 0.05, N = 4). Treated defects contained more mineralized repair tissue than control defects at 3 months (P < 0.05, N = 12). Conclusion: Bone plate–induced chondroinduction is an articular cartilage repair mechanism. Jamshidi biopsy repair takes longer than 3 months and can be influenced by subchondral chitosan-blood implant. PMID:26069656

  4. Transport of dissolved organic matter in Boom Clay: Size effects

    NASA Astrophysics Data System (ADS)

    Durce, D.; Aertsens, M.; Jacques, D.; Maes, N.; Van Gompel, M.

    2018-01-01

    A coupled experimental-modelling approach was developed to evaluate the effects of molecular weight (MW) of dissolved organic matter (DOM) on its transport through intact Boom Clay (BC) samples. Natural DOM was sampled in-situ in the BC layer. Transport was investigated with percolation experiments on 1.5 cm BC samples by measuring the outflow MW distribution (MWD) by size exclusion chromatography (SEC). A one-dimensional reactive transport model was developed to account for retardation, diffusion and entrapment (attachment and/or straining) of DOM. These parameters were determined along the MWD by implementing a discretisation of DOM into several MW points and modelling the breakthrough of each point. The pore throat diameter of BC was determined as 6.6-7.6 nm. Below this critical size, transport of DOM is MW dependent and two major types of transport were identified. Below MW of 2 kDa, DOM was neither strongly trapped nor strongly retarded. This fraction had an averaged capacity factor of 1.19 ± 0.24 and an apparent dispersion coefficient ranging from 7.5 × 10- 11 to 1.7 × 10- 11 m2/s with increasing MW. DOM with MW > 2 kDa was affected by both retardation and straining that increased significantly with increasing MW while apparent dispersion coefficients decreased. Values ranging from 1.36 to 19.6 were determined for the capacity factor and 3.2 × 10- 11 to 1.0 × 10- 11 m2/s for the apparent dispersion coefficient for species with 2.2 kDa < MW < 9.3 kDa. Straining resulted in an immobilisation of in average 49 ± 6% of the injected 9.3 kDa species. Our findings show that an accurate description of DOM transport requires the consideration of the size effects.

  5. Not So Titanic

    NASA Image and Video Library

    2015-07-13

    Titan may be a "large" moon -- its name even implies it! -- but it is still dwarfed by its parent planet, Saturn. As it turns out, this is perfectly normal. Although Titan (3200 miles or 5150 kilometers across) is the second-largest moon in the solar system, Saturn is still much bigger, with a diameter almost 23 times larger than Titan's. This disparity between planet and moon is the norm in the solar system. Earth's diameter is "only" 3.7 times our moon's diameter, making our natural satellite something of an oddity. (Another exception to the rule: dwarf planet Pluto's diameter is just under two times that of its moon.) So the question isn't why is Titan so small (relatively speaking), but why is Earth's moon so big? This view looks toward the anti-Saturn hemisphere of Titan. North on Titan is up. The image was taken with the Cassini spacecraft wide-angle camera on April 18, 2015 using a near-infrared spectral filter with a passband centered at 752 nanometers. The view was acquired at a distance of approximately 930,000 miles (1.5 million kilometers) from Titan. Image scale is 56 miles (90 kilometers) per pixel. http://photojournal.jpl.nasa.gov/catalog/PIA18326

  6. Pratt & Whitney 2D Model in LeRC 9 ft x 15 ft Acoustics

    NASA Technical Reports Server (NTRS)

    Bridges, James; Marino, Jodilyn

    1999-01-01

    The theory of mixer-ejectors for noise suppression is illustrated in this cartoon. Since jet noise SPL scales as velocity to the eighth power and diameter squared, increasing the jet diameter while lowering its velocity and keeping thrust constant decreases the noise. However, in supersonic craft, the drag penalty for increasing diameter at supersonic cruise makes this option very expensive. One would like to have a large engine during takeoff which could be shrunk during cruise. The retractable ejector is such an expandable engine. If the mixer flow can be expanded to the size of the ejector exit, the noise generated downstream of the ejector will be much less than the small diameter mixer nozzle alone. Of course, this also requires that the noise created in expanding the flow to fill the ejector be absorbed by a liner in the ejector walls so that none of this noise is heard. Since this mixing of internal hot gas and external cold air must take place in as short a distance as possible, the mixer must be very effective and therefore probably much noisier than a simple nozzle.

  7. LSST system analysis and integration task for an advanced science and application space platform

    NASA Technical Reports Server (NTRS)

    1980-01-01

    To support the development of an advanced science and application space platform (ASASP) requirements of a representative set of payloads requiring large separation distances selected from the Science and Applications Space Platform data base. These payloads were a 100 meter diameter atmospheric gravity wave antenna, a 100 meter by 100 meter particle beam injection experiment, a 2 meter diameter, 18 meter long astrometric telescope, and a 15 meter diameter, 35 meter long large ambient deployable IR telescope. A low earth orbit at 500 km altitude and 56 deg inclination was selected as being the best compromise for meeting payload requirements. Platform subsystems were defined which would support the payload requirements and a physical platform concept was developed. Structural system requirements which included utilities accommodation, interface requirements, and platform strength and stiffness requirements were developed. An attitude control system concept was also described. The resultant ASASP concept was analyzed and technological developments deemed necessary in the area of large space systems were recommended.

  8. High energy, low frequency, ultrasonic transducer

    DOEpatents

    Brown, Albert E.

    2000-01-01

    A wide bandwidth, ultrasonic transducer to generate nondispersive, extensional, pulsed acoustic pressure waves into concrete reinforced rods and tendons. The wave propagation distance is limited to double the length of the rod. The transducer acoustic impedance is matched to the rod impedance for maximum transfer of acoustic energy. The efficiency of the transducer is approximately 60 percent, depending upon the type of active elements used in the transducer. The transducer input energy is, for example, approximately 1 mJ. Ultrasonic reflections will occur at points along the rod where there are changes of one percent of a wavelength in the rod diameter. A reduction in the rod diameter will reflect a phase reversed echo, as compared with the reflection from an incremental increase in diameter. Echo signal processing of the stored waveform permits a reconstruction of those echoes into an image of the rod. The ultrasonic transducer has use in the acoustic inspection of long (40+foot) architectural reinforcements and structural supporting members, such as in bridges and dams.

  9. Morphology control of PLA microfibers and spheres via melt electrospinning

    NASA Astrophysics Data System (ADS)

    Yu, Shu-Xin; Zheng, Jie; Yan, Xu; Wang, Xiao-Xiong; Nie, Guang-Di; Tan, Ye-Qiang; Zhang, Jun; Sui, Kun-Yan; Long, Yun-Ze

    2018-04-01

    In conventional solution electrospinning, the morphologies (e.g., spheres, beaded fibers, and fibers) of electrospun products can be controlled by solution concentration. Here, we report that the morphologies and structures of polylactic acid (PLA) via melt electrospinning also can be adjusted from microfibers to microspheres by simply increasing the spinning temperature. It was found that with temperature increasing from 200 °C to 240 °C, the average diameter of melt-electrospun PLA fibers decreased from 58.46 to 2.96 μm. Then, beaded fibers and microspheres about 14.5 μm in diameter were collected when the spinning temperature was increased to 250 °C and 260 °C. In addition, we also found that the average PLA fiber diameter decreased with increasing the applied spinning voltage, and increased with the increase of spinning distance. To explain the formation mechanism of different PLA microstructures, rheological property and infrared spectra of PLA under different spinning temperatures were also tested.

  10. Preliminary Assessment Of The Burning Dynamics Of Jp8 Droplets In Microgravity

    NASA Technical Reports Server (NTRS)

    Bae, J. H.; Avedisian, C. T.

    2003-01-01

    In this report we present new data for fuel droplet combustion in microgravity to examine the influence of ambient gas and fuel composition on flame structure and sooting dynamics for droplets with initial diameters in the range of 0.4mm to 0.5mm. The fuels are JP8 (a kerosene derivative) and nonane. The ambient gas is air and a mixture of 30% oxygen and 70% helium, the latter having been examined for burning under conditions where soot formation is minimal. Some data at elevated pressures are also reported. The burning process shows a nonlinear D2 progression which is independent of soot formation as burning in a helium inert showed the same nonlinear trend. Flames were proportionally farther from the droplet surface in helium than they were in air. A nondimensional parameter is presented that consolidates the three standoff distances for the droplet, flame and soot shell diameters within the initial diameter ranges examined.

  11. Measurement and analysis of a small nozzle plume in vacuum

    NASA Technical Reports Server (NTRS)

    Penko, P. F.; Boyd, I. D.; Meissner, D. L.; Dewitt, K. J.

    1993-01-01

    Pitot pressures and flow angles are measured in the plume of a nozzle flowing nitrogen and exhausting to a vacuum. Total pressures are measured with Pitot tubes sized for specific regions of the plume and flow angles measured with a conical probe. The measurement area for total pressure extends 480 mm (16 exit diameters) downstream of the nozzle exit plane and radially to 60 mm (1.9 exit diameters) off the plume axis. The measurement area for flow angle extends to 160 mm (5 exit diameters) downstream and radially to 60 mm. The measurements are compared to results from a numerical simulation of the flow that is based on kinetic theory and uses the direct-simulation Monte Carlo (DSMC) method. Comparisons of computed results from the DSMC method with measurements of flow angle display good agreement in the far-field of the plume and improve with increasing distance from the exit plane. Pitot pressures computed from the DSMC method are in reasonably good agreement with experimental results over the entire measurement area.

  12. A Structured Light Sensor System for Tree Inventory

    NASA Technical Reports Server (NTRS)

    Chien, Chiun-Hong; Zemek, Michael C.

    2000-01-01

    Tree Inventory is referred to measurement and estimation of marketable wood volume in a piece of land or forest for purposes such as investment or for loan applications. Exist techniques rely on trained surveyor conducting measurements manually using simple optical or mechanical devices, and hence are time consuming subjective and error prone. The advance of computer vision techniques makes it possible to conduct automatic measurements that are more efficient, objective and reliable. This paper describes 3D measurements of tree diameters using a uniquely designed ensemble of two line laser emitters rigidly mounted on a video camera. The proposed laser camera system relies on a fixed distance between two parallel laser planes and projections of laser lines to calculate tree diameters. Performance of the laser camera system is further enhanced by fusion of information induced from structured lighting and that contained in video images. Comparison will be made between the laser camera sensor system and a stereo vision system previously developed for measurements of tree diameters.

  13. Ultrafine Ti4+ doped α-Fe2O3 nanorod array photoanodes with high charge separation efficiency for solar water splitting

    NASA Astrophysics Data System (ADS)

    Liu, Yilin; Liu, Jie; Luo, Wenjun; Wen, Xin; Liu, Xiaokang; Zou, Zhigang; Huang, Wei

    2017-06-01

    Hematite (α-Fe2O3) is a promising photoanode material for solar water splitting due to its suitable band gap, earth-abundance, excellent stability and non-toxicity. However, a short hole diffusion length limits its performance. A nanorod array structure can shorten hole transfer distance to photoelectrode/electrolyte interface and decrease recombination of photo-generated carriers. However, average diameters of all previously reported nanorods are over 50 nm, thus being too thick for holes to transfer to the interface. It is still a big challenge to prepare a Fe2O3 nanorod array photoelectrode with finer diameter. In this study, we prepare an ultrafine α-Fe2O3 nanorod array film with average diameter about 25 nm by calcining γ-FeOOH for the first time. The ultrafine nanorod array photoanode indicates much higher carrier separation efficiency and performance than a conventional nanorod array film.

  14. Parametric Investigation of Thrust Augmentation by Ejectors on a Pulsed Detonation Tube

    NASA Technical Reports Server (NTRS)

    Wilson, Jack; Sgondea, Alexandru; Paxson, Daniel E.; Rosenthal, Bruce N.

    2005-01-01

    A parametric investigation has been made of thrust augmentation of a 1 inch diameter pulsed detonation tube by ejectors. A set of ejectors was used which permitted variation of the ejector length, diameter, and nose radius, according to a statistical design of experiment scheme. The maximum augmentations for each ejector were fitted using a polynomial response surface, from which the optimum ejector diameters, and nose radius, were found. Thrust augmentations above a factor of 2 were measured. In these tests, the pulsed detonation device was run on approximately stoichiometric air-hydrogen mixtures, at a frequency of 20 Hz. Later measurements at a frequency of 40 Hz gave lower values of thrust augmentation. Measurements of thrust augmentation as a function of ejector entrance to detonation tube exit distance showed two maxima, one with the ejector entrance upstream, and one downstream, of the detonation tube exit. A thrust augmentation of 2.5 was observed using a tapered ejector.

  15. Nasolabial Morphology Following Nasoalveolar Molding in Infants With Unilateral Cleft Lip and Palate.

    PubMed

    Nur Yilmaz, Rahime Burcu; Germeç Çakan, Derya

    2018-06-01

    The aim of the present study is to evaluate the effects of nasoalveolar molding (NAM) therapy on nasolabial morphology three dimensionally, and compare the nasolabial linear and surface distance measurements in infants with unilateral cleft lip and palate. Facial plaster casts of 42 infants with unilateral cleft lip and palate taken at the onset (pre-NAM) and finishing stage (post-NAM) of NAM were scanned with 3dMDface stereophotogrammetry system (3dMD, Atlanta, GA). Nineteen nasolabial linear and surface distance measurements were performed on three-dimensional images. In addition to standard descriptive statistical calculations (means and SDs), pre- and post-NAM measurements were evaluated by paired t test. All measurements except lip gap, nostril floor width, and nostril diameter increased between pre-NAM and post-NAM. Nostril and lip height increased significantly on the cleft side (P < 0.05). No differences were present between linear and surface distance measurements except for nasal width measurement. Nasal and lip symmetry improved with NAM. The use of surface distance measurements may be advised particularly for continuous and curved anatomic structures in which circumference differences are expected.

  16. Tactical decisions for changeable cuttlefish camouflage: visual cues for choosing masquerade are relevant from a greater distance than visual cues used for background matching.

    PubMed

    Buresch, Kendra C; Ulmer, Kimberly M; Cramer, Corinne; McAnulty, Sarah; Davison, William; Mäthger, Lydia M; Hanlon, Roger T

    2015-10-01

    Cuttlefish use multiple camouflage tactics to evade their predators. Two common tactics are background matching (resembling the background to hinder detection) and masquerade (resembling an uninteresting or inanimate object to impede detection or recognition). We investigated how the distance and orientation of visual stimuli affected the choice of these two camouflage tactics. In the current experiments, cuttlefish were presented with three visual cues: 2D horizontal floor, 2D vertical wall, and 3D object. Each was placed at several distances: directly beneath (in a circle whose diameter was one body length (BL); at zero BL [(0BL); i.e., directly beside, but not beneath the cuttlefish]; at 1BL; and at 2BL. Cuttlefish continued to respond to 3D visual cues from a greater distance than to a horizontal or vertical stimulus. It appears that background matching is chosen when visual cues are relevant only in the immediate benthic surroundings. However, for masquerade, objects located multiple body lengths away remained relevant for choice of camouflage. © 2015 Marine Biological Laboratory.

  17. 3D interferometric shape measurement technique using coherent fiber bundles

    NASA Astrophysics Data System (ADS)

    Zhang, Hao; Kuschmierz, Robert; Czarske, Jürgen

    2017-06-01

    In-situ 3-D shape measurements with submicron shape uncertainty of fast rotating objects in a cutting lathe are expected, which can be achieved by simultaneous distance and velocity measurements. Conventional tactile methods, coordinate measurement machines, only support ex-situ measurements. Optical measurement techniques such as triangulation and conoscopic holography offer only the distance, so that the absolute diameter cannot be retrieved directly. In comparison, laser Doppler distance sensors (P-LDD sensor) enable simultaneous and in-situ distance and velocity measurements for monitoring the cutting process in a lathe. In order to achieve shape measurement uncertainties below 1 μm, a P-LDD sensor with a dual camera based scattered light detection has been investigated. Coherent fiber bundles (CFB) are employed to forward the scattered light towards cameras. This enables a compact and passive sensor head in the future. Compared with a photo detector based sensor, the dual camera based sensor allows to decrease the measurement uncertainty by the order of one magnitude. As a result, the total shape uncertainty of absolute 3-D shape measurements can be reduced to about 100 nm.

  18. Distance and absolute magnitudes of the brightest stars in the dwarf galaxy Sextans A

    NASA Technical Reports Server (NTRS)

    Sandage, A.; Carlson, G.

    1982-01-01

    In an attempt to improve present bright star calibration, data were gathered for the brightest red and blue stars and the Cepheids in the Im V dwarf galaxy, Sextans A. On the basis of a magnitude sequence measured to V and B values of about 22 and 23, respectively, the mean magnitudes of the three brightest blue stars are V=17.98 and B=17.88. The three brightest red supergiants have V=18.09 and B=20.14. The periods and magnitudes measured for five Cepheids yield an apparent blue distance modulus of 25.67 + or - 0.2, via the P-L relation, and the mean absolute magnitudes of V=-7.56 and B=-5.53 for the red supergiants provide additional calibration of the brightest red stars as distance indicators. If Sextans A were placed at the distance of the Virgo cluster, it would appear to have a surface brightness of 23.5 mag/sq arcec. This, together with the large angular diameter, would make such a galaxy easily discoverable in the Virgo cluster by means of ground-based surveys.

  19. Inelastic X-ray Scattering Studies of Plasmons in Carbon Nanotubes

    NASA Astrophysics Data System (ADS)

    Upton, M. H.; Klie, R. F.; Hill, J. P.; Gog, T.; Casa, D.; Ku, W.; Zhu, Y.; Sfeir, M. Y.; Misewich, J.; Eres, G.; Lowndes, D.

    2007-03-01

    We investigate the physical parameters controlling the low energy screening in carbon nanotubes via electron energy loss spectroscopy and inelastic x-ray scattering. Two plasmon-like features are observed, one near 9 eV (the so- called π plasmon) and one near 20 eV (the so-called π+σ plasmon). At large nanotube diameters, the π+σ plasmon energies depend exclusively on the number of walls and not on the radius or chiral vector. This shift indicates a change of strength of screening and the effective interaction at inter-atomic distance, and thus suggests an alternative mechanism of tuning the properties of the nanotube in addition to the well-known control provided by chirality and tube diameter.

  20. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ibrahim, Illani; Sekak, Khairunnadim Ahmad; Hasbullah, Norazurean

    Researches on the fabrication of nanostructured based membrane have attracted great attention amongst scientists due to their wide potential applications on medical application. In this work, Chitosan and Aloe Vera sol-gel solution were electrospun using 20 kV DC supply at room temperature. Morphological structure and functional group of nanofibers were characterized using field emission scanning electron microscopy (FESEM) and Fourier-transform infrared spectroscopy (FT-IR) respectively. The optimum parameter obtained at 90% concentration of acetic acid, 0.3 ml/h of solution flow rate and 10 cm distance of nozzle to collector. The fiber diameters were analyzed using the ImageJ software. Average diameters of the Chitosan/Aloe Veramore » composite nanofibers is 183nm in ranges of 140–260nm.« less

  1. Preparation and characterization of chitosan/Aloe Vera composite nanofibers generated by electrostatic spinning

    NASA Astrophysics Data System (ADS)

    Ibrahim, Illani; Sekak, Khairunnadim Ahmad; Hasbullah, Norazurean

    2015-08-01

    Researches on the fabrication of nanostructured based membrane have attracted great attention amongst scientists due to their wide potential applications on medical application. In this work, Chitosan and Aloe Vera sol-gel solution were electrospun using 20 kV DC supply at room temperature. Morphological structure and functional group of nanofibers were characterized using field emission scanning electron microscopy (FESEM) and Fourier-transform infrared spectroscopy (FT-IR) respectively. The optimum parameter obtained at 90% concentration of acetic acid, 0.3 ml/h of solution flow rate and 10 cm distance of nozzle to collector. The fiber diameters were analyzed using the ImageJ software. Average diameters of the Chitosan/Aloe Vera composite nanofibers is 183nm in ranges of 140-260nm.

  2. Anatomical Study of Healthy Aortic Arches.

    PubMed

    Girsowicz, Elie; Georg, Yannick; Lefebvre, François; Lejay, Anne; Thaveau, Fabien; Roy, Catherine; Ohana, Mickael; Chakfe, Nabil

    2017-10-01

    With the steady increase of endovascular procedures involving the aortic arch (AA), an actual depiction of its anatomy has become mandatory. It has also become necessary to evaluate the natural evolution of the AA morphology as part of the evaluation of endovascular devices durability. The objective of this study was to perform a morphological and anatomical study of the AA and of the supra aortic trunks (SAT) in healthy patients, with an evaluation of their evolution with time, with a specific orientation applied to endovascular therapies of the AA. Sixty-one patients (31 men, mean age 50.8 [18-82]) with a normal anatomy were included in the study. Measurements included the diameters of the AA and SAT in 17 locations, their distance and angulation based on computed tomography angiography data. Statistical analysis focused on descriptive statistics, differences between genders, as well as correlations with age. Aortic diameters (mean ± SD) were 29.5 ± 3.9 mm at the ascending aorta, 28.6 ± 3.9 mm at the innominate artery (IA), 27.1 ± 3.2 mm at the left common carotid artery (LCCA), 25.3 ± 3.0 mm at the left subclavian artery (LSCA), 23.9 ± 3.3 mm at the descending aorta. Mean angulation of the AA was 82° (95% confidence interval [CI]: 78.95-85.19°), mean angulation between LSCA/LCCA was -5.7° (95% CI: -0.9 to 18.7°) and -1.8° (95% CI: 5.4-26.4°) between LCCA/IA. Mean distance between the LSCA and the LCCA was 14.3 mm (95% CI: 13-15.6 mm) and 21.8 mm (95% CI: 20.3-23.4 mm) between LCCA and IA. All diameters of the AA increased with age (P < 0.05). Men had diameters statistically (P < 0.05) greater than women except at the LCCA ostium level. A statistically significant increase of the distances between the LSCA and the LCCA, between the LSCA and the IA and between the IA and the LCCA was found with age, P = 0.027, <0.01 and 0.012 respectively. This study allows obtaining accurate information of the AA and the SAT anatomy. It enabled to obtain a better understanding of the three-dimensional aspects of the AA, confirmed the variability and heterogeneity of the SAT disposition, and discussed the principles of vascular aging. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Reference Values for Central Airway Dimensions on CT Images of Children and Adolescents.

    PubMed

    Kuo, Wieying; Ciet, Pierluigi; Andrinopoulou, Eleni-Rosalina; Chen, Yong; Pullens, Bas; Garcia-Peña, Pilar; Fleck, Robert J; Paoletti, Matteo; McCartin, Michael; Vermeulen, Francois; Morana, Giovanni; Lee, Edward Y; Tiddens, Harm A W M

    2018-02-01

    The purpose of this study was to acquire normative data on central airway dimensions on chest CT scans in the pediatric population. Chest CT findings reported as normal by a radiologist were collected retrospectively at 10 international centers. An experienced and independent thoracic radiologist reevaluated all CT scans for image quality and for normal findings. Semiautomated image analysis was performed to measure dimensions of the trachea and right and left main bronchi at inspiration. Intrathoracic tracheal length was measured from carina to thorax inlet. Cross-sectional area and short and long axes were measured perpendicular to the longitudinal airway axis starting from the carina every centimeter upward for the trachea and every 0.5 cm downward for the main bronchi. The effects on airway diameters of age, sex, intrathoracic tracheal length, and distance from the carina were investigated by use of mixed-effects models analysis. Among 1160 CT scans collected, 388 were evaluated as normal by the independent radiologist with sufficient image quality and adequate inspiratory volume level. Central airways were successfully semiautomatically analyzed in 294 of 388 CT studies. Age, sex, intrathoracic tracheal length, and distance from carina were all significant predictors in the models for tracheal and right and left main bronchial diameters (p < 0.001). The central airway dimensions increased with age up to 20 years, and dimensions were larger in male than in female adolescents. Normative data were determined for the central airways of children and adolescents. Central airway dimensions depended on distance from the carina and on intrathoracic tracheal length.

  4. Technical Note: On EM reconstruction of a multi channel shielded applicator for cervical cancer brachytherapy: A feasibility study.

    PubMed

    Tho, Daline; Racine, Emmanuel; Easton, Harry; Song, William Y; Beaulieu, Luc

    2018-04-01

    Electromagnetic tracking (EMT) is a promising technology for automated catheter and applicator reconstructions in brachytherapy. In this work, a proof-of-concept is presented for reconstruction of the individual channels of a new shielded tandem (140 mm long shield) dedicated to intensity-modulated brachytherapy. All six channels of a straight prototype were reconstructed using an electromagnetic (EM) system from Aurora (NDI, Waterloo, ON, Canada). The influence of the shield on the EMT system was characterized by taking measurements at nine different positions with and without the shielded part of the applicator next to the probe. A Student t-test was used to analyze the data. For registration purposes, the center-to-center distance (4 mm) was taken from the computed-assisted design (CAD) structure. The computed interchannel distances from the three opposite pairs were 4.33 ± 0.40 mm, 4.14 ± 0.35 mm, and 3.88 ± 0.26 mm. All interchannel distances were within the geometrical tolerance in the shielded portion of the applicator (±0.6 mm) and account for the fact that the sensor (0.8 mm diameter) was smaller than the channel diameter. According to the paired Student t-test, the data given by the EM system with and without the shielded applicator tip are not significantly different. This study shows that the reconstruction of channel path is possible within the mechanical accuracy of the applicator. © 2018 American Association of Physicists in Medicine.

  5. Mixing of Supersonic Streams

    NASA Technical Reports Server (NTRS)

    Hawk, C. W.; Landrum, D. B.; Muller, S.; Turner, M.; Parkinson, D.

    1998-01-01

    The Strutjet approach to Rocket Based Combined Cycle (RBCC) propulsion depends upon fuel-rich flows from the rocket nozzles and turbine exhaust products mixing with the ingested air for successful operation in the ramjet and scramjet modes. It is desirable to delay this mixing process in the air-augmented mode of operation present during low speed flight. A model of the Strutjet device has been built and is undergoing test to investigate the mixing of the streams as a function of distance from the Strutjet exit plane during simulated low speed flight conditions. Cold flow testing of a 1/6 scale Strutjet model is underway and nearing completion. Planar Laser Induced Fluorescence (PLIF) diagnostic methods are being employed to observe the mixing of the turbine exhaust gas with the gases from both the primary rockets and the ingested air simulating low speed, air augmented operation of the RBCC. The ratio of the pressure in the turbine exhaust duct to that in the rocket nozzle wall at the point of their intersection is the independent variable in these experiments. Tests were accomplished at values of 1.0, 1.5 and 2.0 for this parameter. Qualitative results illustrate the development of the mixing zone from the exit plane of the model to a distance of about 10 rocket nozzle exit diameters downstream. These data show the mixing to be confined in the vertical plane for all cases, The lateral expansion is more pronounced at a pressure ratio of 1.0 and suggests that mixing with the ingested flow would be likely beginning at a distance of 7 nozzle exit diameters downstream of the nozzle exit plane.

  6. Intensive field phenotyping of maize (Zea mays L.) root crowns identifies phenes and phene integration associated with plant growth and nitrogen acquisition

    PubMed Central

    York, Larry M.; Lynch, Jonathan P.

    2015-01-01

    Root architecture is an important regulator of nitrogen (N) acquisition. Existing methods to phenotype the root architecture of cereal crops are generally limited to seedlings or to the outer roots of mature root crowns. The functional integration of root phenes is poorly understood. In this study, intensive phenotyping of mature root crowns of maize was conducted to discover phenes and phene modules related to N acquisition. Twelve maize genotypes were grown under replete and deficient N regimes in the field in South Africa and eight in the USA. An image was captured for every whorl of nodal roots in each crown. Custom software was used to measure root phenes including nodal occupancy, angle, diameter, distance to branching, lateral branching, and lateral length. Variation existed for all root phenes within maize root crowns. Size-related phenes such as diameter and number were substantially influenced by nodal position, while angle, lateral density, and distance to branching were not. Greater distance to branching, the length from the shoot to the emergence of laterals, is proposed to be a novel phene state that minimizes placing roots in already explored soil. Root phenes from both older and younger whorls of nodal roots contributed to variation in shoot mass and N uptake. The additive integration of root phenes accounted for 70% of the variation observed in shoot mass in low N soil. These results demonstrate the utility of intensive phenotyping of mature root systems, as well as the importance of phene integration in soil resource acquisition. PMID:26041317

  7. Distribution of shortest path lengths in a class of node duplication network models

    NASA Astrophysics Data System (ADS)

    Steinbock, Chanania; Biham, Ofer; Katzav, Eytan

    2017-09-01

    We present analytical results for the distribution of shortest path lengths (DSPL) in a network growth model which evolves by node duplication (ND). The model captures essential properties of the structure and growth dynamics of social networks, acquaintance networks, and scientific citation networks, where duplication mechanisms play a major role. Starting from an initial seed network, at each time step a random node, referred to as a mother node, is selected for duplication. Its daughter node is added to the network, forming a link to the mother node, and with probability p to each one of its neighbors. The degree distribution of the resulting network turns out to follow a power-law distribution, thus the ND network is a scale-free network. To calculate the DSPL we derive a master equation for the time evolution of the probability Pt(L =ℓ ) , ℓ =1 ,2 ,⋯ , where L is the distance between a pair of nodes and t is the time. Finding an exact analytical solution of the master equation, we obtain a closed form expression for Pt(L =ℓ ) . The mean distance 〈L〉 t and the diameter Δt are found to scale like lnt , namely, the ND network is a small-world network. The variance of the DSPL is also found to scale like lnt . Interestingly, the mean distance and the diameter exhibit properties of a small-world network, rather than the ultrasmall-world network behavior observed in other scale-free networks, in which 〈L〉 t˜lnlnt .

  8. Human Factors and Safety Considerations of Night Vision Systems Flight Using Thermal Imaging Systems

    DTIC Science & Technology

    1990-04-01

    s4 tank with engine, drive playa that are twit very daIrk in the kcast brightest wheel-, and eXhSAus at temprrAtures between M5 anid Warea IvPKlly...be presented to the pilot on a miniature (1- sources, when viewed through the combiner, degra- inch diameter) cathodec ray tube (CRT) in the de the...performance. Also. flme Ccas Affect the display’s performance as well. The see-through chrsctcrisics of the display permit de Unlike sytcms using the

  9. Presettlement Forests of the Black Swamp Area, Cache River,Woodruff County, Arkansas, from Notes of the First Land Survey

    Treesearch

    Thomas L. Foti

    2001-01-01

    Relationships between forest vegetation and soil were reconstructed from field notes of the 1846 Public Land Survey (PLS) along a portion of the Cache River including Black Swamp. Locations of corners were digitized long with species,diameter,and distance from section or quarter-section corners. Trees were grouped for analysis according to occurrence on groups of...

  10. Planetary astronomy program

    NASA Technical Reports Server (NTRS)

    Chapman, C. R.; Hartmann, W. K.

    1978-01-01

    Observations and analyses of asteroids, Trojans and cometary nuclei are presented. Spectrophotometry was used to observe the cometary nuclei. The spectra are plotted as a function of semimajor axis and eccentricity. Trojans and other asteroids at great solar distances show a variety of spectra, many of them quite red despite the low measured albedoes for many of these asteroids. The asteroid spectra are grouped according to diameter and taxonomic class.

  11. Cost of thinning 50-year-old Douglas-fir for pulpwood at Voight Creek Experimental Forest.

    Treesearch

    Norman P. Worthington

    1961-01-01

    Analyses of time and cost data gathered on the Voight Creek Experimental Forest from six thinnings in a 50-year-old stand of Douglas-fir showed that average skidding distance and diameter of average tree cut were the chief factors affecting the production time in thinning these pulpwood stands. Cut per acre had negligible influence. Contractors' production...

  12. Influence of detector pixel size, TOF resolution and DOI on image quality in MR-compatible whole-body PET.

    PubMed

    Thoen, Hendrik; Keereman, Vincent; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2013-09-21

    The optimization of a whole-body PET system remains a challenging task, as the imaging performance is influenced by a complex interaction of different design parameters. However, it is not always clear which parameters have the largest impact on image quality and are most eligible for optimization. To determine this, we need to be able to assess their influence on image quality. We performed Monte-Carlo simulations of a whole-body PET scanner to predict the influence on image quality of three detector parameters: the TOF resolution, the transverse pixel size and depth-of-interaction (DOI)-correction. The inner diameter of the PET scanner was 65 cm, small enough to allow physical integration into a simultaneous PET-MR system. Point sources were used to evaluate the influence of transverse pixel size and DOI-correction on spatial resolution as function of radial distance. To evaluate the influence on contrast recovery and pixel noise a cylindrical phantom of 35 cm diameter was used, representing a large patient. The phantom contained multiple hot lesions with 5 mm diameter. These lesions were placed at radial distances of 50, 100 and 150 mm from the center of the field-of-view, to be able to study the effects at different radial positions. The non-prewhitening (NPW) observer was used for objective analysis of the detectability of the hot lesions in the cylindrical phantom. Based on this analysis the NPW-SNR was used to quantify the relative improvements in image quality due to changes of the variable detector parameters. The image quality of a whole-body PET scanner can be improved significantly by reducing the transverse pixel size from 4 to 2.6 mm and improving the TOF resolution from 600 to 400 ps and further from 400 to 200 ps. Compared to pixel size, the TOF resolution has the larger potential to increase image quality for the simulated phantom. The introduction of two layer DOI-correction only leads to a modest improvement for the spheres at radial distance of 150 mm from the center of the transaxial FOV.

  13. Experimental study on impact-induced seismic wave propagating through quartz sand simulating asteroid regolith

    NASA Astrophysics Data System (ADS)

    Matsue, Kazuma; Arakawa, Masahiko; Yasui, Minami; Matsumoto, Rie; Tsujido, Sayaka; Takano, Shota; Hasegawa, Sunao

    2015-08-01

    Introduction: Recent spacecraft surveys clarified that asteroid surfaces were covered with regolith made of boulders and pebbles such as that found on the asteroid Itokawa. It was also found that surface morphologies of asteroids formed on the regolith layer were modified. For example, the high-resolution images of the asteroid Eros revealed the evidence of the downslope movement of the regolith layer, then it could cause the degradation and the erasure of small impact crater. One possible process to explain these observations is the regolith layer collapse caused by seismic vibration after projectile impacts. The impact-induced seismic wave might be an important physical process affecting the morphology change of regolith layer on asteroid surfaces. Therefore, it is significant for us to know the relationship between the impact energy and the impact-induced seismic wave. So in this study, we carried out impact cratering experiments in order to observe the seismic wave propagating through the target far from the impact crater.Experimental method: Impact cratering experiments were conducted by using a single stage vertical gas gun set at Kobe Univ and a two-stage vertical gas gun set at ISAS. We used quartz sands with the particle diameter of 500μm, and the bulk density of 1.48g/cm3. The projectile was a ball made of polycarbonate with the diameter of 4.75mm and aluminum, titan, zirconia, stainless steel, cupper, tungsten carbide projectile with the diameter of 2mm. These projectiles were launched at the impact velocity from 0.2 to 7km/s. The target was set in a vacuum chamber evacuated below 10 Pa. We measured the seismic wave by using a piezoelectric uniaxial accelerometer.Result: The impact-induced seismic wave was measured to show a large single peak and found to attenuate with the propagation distance. The maximum acceleration of the seismic wave was recognized to have a good relationship with the normalized distance x/R, where x is the propagation distance and R is the crater radius, irrespective of the impact velocities: gmax = 160(x/R)-2.98.

  14. Morphometric analysis of cervical spinal canal diameter, transverse foramen, and pedicle width using computed tomography in Indian population.

    PubMed

    Sureka, Binit; Mittal, Aliza; Mittal, Mahesh K; Agarwal, Kanhaiya; Sinha, Mukul; Thukral, Brij Bhushan

    2018-01-01

    Accurate and detailed measurements of spinal canal diameter (SCD) and transverse foraminal morphometry are essential for understanding spinal column-related diseases and for surgical planning, especially for transpedicular screw fixation. This is especially because lateral cervical radiographs do not provide accurate measurements. This study was conducted to measure the dimensions of the transverse foramen sagittal and transverse diameters (SFD, TFD), SCD, and the distance of spinal canal from the transverse foramina (dSC-TF) at C1-C7 level in the Indian population. The study population comprised 84 male and 42 female subjects. The mean age of the study group was 44.63 years (range, 19-81 years). A retrospective study was conducted, and data were collected and analyzed for patients who underwent cervical spine computed tomography (CT) imaging for various reasons. One hundred and twenty-six patients were included in the study. Detailed readings were taken at all levels from C1-C7 for SCD, SFD, TFD, and dSc-TF. Values for male and female subjects were separately calculated and compared. For both the groups, the widest SCD were measured at the C1 level and the narrowest SCD at the C4 level. The narrowest SFD was measured at C7 for both male and female subjects on the right and left sides. The widest SFD was measured at C1 both for male and female subjects on the right and left side. The narrowest TFD on the left side was measured at C7 for male and at C1 for female subjects. The narrowest mean distance of dSC-TF was found to be at C4 for both male and female subjects on both left and right side. The computed tomographic (CT) imaging is better than conventional radiographs for the preoperative evaluation of cervical spine and for better understanding cervical spine morphometry. Care must be taken during transpedicular screw fixation, especially in female subjects, more so at the C2, C4, and C6 levels due to a decrease in the distance of dSC-TF.

  15. Evaluation of a coupled dispersion and aerosol process model against measurements near a major road

    NASA Astrophysics Data System (ADS)

    Pohjola, M. A.; Pirjola, L.; Karppinen, A.; Härkönen, J.; Ketzel, M.; Kukkonen, J.

    2007-02-01

    A field measurement campaign was conducted near a major road "Itäväylä" in an urban area in Helsinki in 17-20 February 2003. Aerosol measurements were conducted using a mobile laboratory "Sniffer" at various distances from the road, and at an urban background location. Measurements included particle size distribution in the size range of 7 nm-10 μm (aerodynamic diameter) by the Electrical Low Pressure Impactor (ELPI) and in the size range of 3-50 nm (mobility diameter) by Scanning Mobility Particle Sizer (SMPS), total number concentration of particles larger than 3 nm detected by an ultrafine condensation particle counter (UCPC), temperature, relative humidity, wind speed and direction, driving route of the mobile laboratory, and traffic density on the studied road. In this study, we have compared measured concentration data with the predictions of the road network dispersion model CAR-FMI used in combination with an aerosol process model MONO32. The vehicular exhaust emissions, and atmospheric dispersion and transformation of fine and ultrafine particles was evaluated within the distance scale of 200 m (corresponding to a time scale of a couple of minutes). We computed the temporal evolution of the number concentrations, size distributions and chemical compositions of various particle size classes. The atmospheric dilution rate of particles is obtained from the roadside dispersion model CAR-FMI. Considering the evolution of total number concentration, dilution was shown to be the most important process. The influence of coagulation and condensation on the number concentrations of particle size modes was found to be negligible at this distance scale. Condensation was found to affect the evolution of particle diameter in the two smallest particle modes. The assumed value of the concentration of condensable organic vapour of 1012 molecules cm-3 was shown to be in a disagreement with the measured particle size evolution, while the modelling runs with the concentration of condensable organic vapour of 109-1010 molecules cm-3 resulted in particle sizes that were closest to the measured values.

  16. Size-dependent characterization of embedded Ge nanocrystals: Structural and thermal properties

    NASA Astrophysics Data System (ADS)

    Araujo, L. L.; Giulian, R.; Sprouster, D. J.; Schnohr, C. S.; Llewellyn, D. J.; Kluth, P.; Cookson, D. J.; Foran, G. J.; Ridgway, M. C.

    2008-09-01

    A combination of conventional and synchrotron-based techniques has been used to characterize the size-dependent structural and thermal properties of Ge nanocrystals (NCs) embedded in a silica (a-SiO2) matrix. Ge NC size distributions with four different diameters ranging from 4.0 to 9.0 nm were produced by ion implantation and thermal annealing as characterized with small-angle x-ray scattering and transmission electron microscopy. The NCs were well represented by the superposition of bulklike crystalline and amorphous environments, suggesting the formation of an amorphous layer separating the crystalline NC core and the a-SiO2 matrix. The amorphous fraction was quantified with x-ray-absorption near-edge spectroscopy and increased as the NC diameter decreased, consistent with the increase in surface-to-volume ratio. The structural parameters of the first three nearest-neighbor shells were determined with extended x-ray-absorption fine-structure (EXAFS) spectroscopy and evolved linearly with inverse NC diameter. Specifically, increases in total disorder, interatomic distance, and the asymmetry in the distribution of distances were observed as the NC size decreased, demonstrating that finite-size effects govern the structural properties of embedded Ge NCs. Temperature-dependent EXAFS measurements in the range of 15-300 K were employed to probe the mean vibrational frequency and the variation of the interatomic distance distribution (mean value, variance, and asymmetry) with temperature for all NC distributions. A clear trend of increased stiffness (higher vibrational frequency) and decreased thermal expansion with decreasing NC size was evident, confirming the close relationship between the variation of structural and thermal/vibrational properties with size for embedded Ge NCs. The increase in surface-to-volume ratio and the presence of an amorphous Ge layer separating the matrix and crystalline NC core are identified as the main factors responsible for the observed behavior, with the surrounding a-SiO2 matrix also contributing to a lesser extent. Such results are compared to previous reports and discussed in terms of the influence of the surface-to-volume ratio in objects of nanometer dimensions.

  17. The clustering of the SDSS-IV extended Baryon Oscillation Spectroscopic Survey DR14 quasar sample: structure growth rate measurement from the anisotropic quasar power spectrum in the redshift range 0.8 < z < 2.2

    NASA Astrophysics Data System (ADS)

    Gil-Marín, Héctor; Guy, Julien; Zarrouk, Pauline; Burtin, Etienne; Chuang, Chia-Hsun; Percival, Will J.; Ross, Ashley J.; Ruggeri, Rossana; Tojerio, Rita; Zhao, Gong-Bo; Wang, Yuting; Bautista, Julian; Hou, Jiamin; Sánchez, Ariel G.; Pâris, Isabelle; Baumgarten, Falk; Brownstein, Joel R.; Dawson, Kyle S.; Eftekharzadeh, Sarah; González-Pérez, Violeta; Habib, Salman; Heitmann, Katrin; Myers, Adam D.; Rossi, Graziano; Schneider, Donald P.; Seo, Hee-Jong; Tinker, Jeremy L.; Zhao, Cheng

    2018-06-01

    We analyse the clustering of the Sloan Digital Sky Survey IV extended Baryon Oscillation Spectroscopic Survey Data Release 14 quasar sample (DR14Q). We measure the redshift space distortions using the power-spectrum monopole, quadrupole, and hexadecapole inferred from 148 659 quasars between redshifts 0.8 and 2.2, covering a total sky footprint of 2112.9 deg2. We constrain the logarithmic growth of structure times the amplitude of dark matter density fluctuations, fσ8, and the Alcock-Paczynski dilation scales that allow constraints to be placed on the angular diameter distance DA(z) and the Hubble H(z) parameter. At the effective redshift of zeff = 1.52, fσ8(zeff) = 0.420 ± 0.076, H(z_eff)=[162± 12] (r_s^fid/r_s) {km s}^{-1} Mpc^{-1}, and D_A(z_eff)=[1.85± 0.11]× 10^3 (r_s/r_s^fid) Mpc, where rs is the comoving sound horizon at the baryon drag epoch and the superscript `fid' stands for its fiducial value. The errors take into account the full error budget, including systematics and statistical contributions. These results are in full agreement with the current Λ-Cold Dark Matter cosmological model inferred from Planck measurements. Finally, we compare our measurements with other eBOSS companion papers and find excellent agreement, demonstrating the consistency and complementarity of the different methods used for analysing the data.

  18. Ovulation-inducing factor: a protein component of llama seminal plasma

    PubMed Central

    2010-01-01

    Background Previously, we documented the presence of ovulation-inducing factor (OIF) in the seminal plasma of llamas and alpacas. The purpose of the study was to define the biochemical characteristics of the molecule(s) in seminal plasma responsible for inducing ovulation. Methods In Experiment 1, llama seminal plasma was centrifuged using filtration devices with nominal molecular mass cut-offs of 30, 10 and 5 kDa. Female llamas (n = 9 per group) were treated i.m. with whole seminal plasma (positive control), phosphate-buffered saline (negative control), or the fraction of seminal plasma equal or higher than 30 kDa, 10 to 30 kDa, 5 to 10 kDa, or < 5 kDa. In Experiment 2, female llamas (n = 7 per group) were given an i.m. dose of seminal plasma treated previously by: 1) enzymatic digestion with proteinase-K, 2) incubation with charcoal-dextran, 3) heating to 65°C, or 4) untreated (control). In Experiment 3, female llamas (n = 10 per group) were given an i.m. dose of pronase-treated or non-treated (control) seminal plasma. In all experiments, llamas were examined by transrectal ultrasonography to detect ovulation and CL formation. Ovulation rate was compared among groups by Fisher's exact test and follicle and CL diameters were compared among groups by analyses of variance or student's t-tests. Results In Experiment 1, all llamas in the equal or higher than 30 kDa and positive control groups ovulated (9/9 in each), but none ovulated in the other groups (P < 0.001). In Experiment 2, ovulations were detected in all llamas in each treatment group; i.e., respective treatments of seminal plasma failed to inactivate the ovulation-inducing factor. In Experiment 3, ovulations were detected in 0/10 llamas given pronase-treated seminal plasma and in 9/10 controls (P < 0.01). Conclusions We conclude that ovulation-inducing factor (OIF) in llama seminal plasma is a protein molecule that is resistant to heat and enzymatic digestion with proteinase K, and has a molecular mass of approximately equal or higher than 30 kDa. PMID:20462434

  19. Compositional Variegation of Large-Diameter Low-Albedo Asteroids

    NASA Astrophysics Data System (ADS)

    Vilas, F.; Jarvis, K. S.; Anz-Meador, T. D.; Thibault, C. A.; Sawyer, S. R.; Fitzsimmons, A.

    1997-07-01

    Asteroids showing signs of aqueous alteration and thermal metamorphism in visible/near IR spectroscopy and photometry (C, G, F, B, and P classes) ranging from 0.37 - 0.90mu m dominate the asteroid population at heliocentric distances of 2.6 - 3.5 AU. Age dating of meteorites indicates that the Solar System was subjected to a major heating event 4.5 Gyr ago. Recent meteoritic research has produced evidence of a carbonaceous chondrite subjected to two separate aqueous alteration events with a metamorphic heating inbetween (Krot et al., 1997, submitted). Models of the effects of heating by electromagnetic induction or decay of short-lived radionuclides combined with models of the early collisional history of the Solar System after Jupiter's formation indicate that asteroids observed today can be divided into two groups by diameter. Those asteroids having diameters greater than 100 km were mixed by multiple collisions but remain as gravitationally bound rubble piles. Asteroids with diameters less than 100 km should show more compositional diversity. Vilas and Sykes (1996, Icarus, v. 124, 483) have shown using ECAS photometry that this compositional difference exists. Those asteroids having diameters greater than 100 km should be individually homogeneous, with spectral differences showing the combined effects of a primordial compositional gradient in the asteroid belt with thermal metamorphism. We address the significance of spatially-resolved spectra of 42 asteroids to the collective origin of these asteroids.

  20. Sound Radiation from a Supersonic Jet Passing Through a Partially Open Exhaust Duct

    NASA Technical Reports Server (NTRS)

    Kandula, Max

    2011-01-01

    The radiation of sound from a perfectly expanded Mach 2.5 cold supersonic jet of 25.4 mm exit diameter flowing through a partially open rigid-walled duct with an upstream i-deflector has been studied experimentally. In the experiments, the nozzle is mounted vertically, with the nozzle exit plane at a height of 73 jet diameters above ground level. Relative to the nozzle exit plane (NEP), the location of the duct inlet is varied at 10, 5, and -1 jet diameters. Far-field sound pressure levels were obtained at 54 jet diameters above ground with the aid of acoustic sensors equally spaced around a circular arc of radius equal to 80 jet diameters from the jet axis. Data on the jet acoustic field for the partially open duct were obtained and compared with those with a free jet and with a closed duct. The results suggest that for the partially open duct the overall sound pressure level (OASPL) decreases as the distance between the NEP and the duct inlet plane decreases, while the opposite trend is observed for the closed duct. It is also concluded that the observed peak frequency in the partially open duct increases above the free jet value as the angle from the duct axis is increased, and as the duct inlet plane becomes closer to the NEP.

Top