Habacha, Hamdi; Moreau, David; Jarraya, Mohamed; Lejeune-Poutrain, Laure; Molinaro, Corinne
2018-01-01
The effect of stimuli size on the mental rotation of abstract objects has been extensively investigated, yet its effect on the mental rotation of bodily stimuli remains largely unexplored. Depending on the experimental design, mentally rotating bodily stimuli can elicit object-based transformations, relying mainly on visual processes, or egocentric transformations, which typically involve embodied motor processes. The present study included two mental body rotation tasks requiring either a same-different or a laterality judgment, designed to elicit object-based or egocentric transformations, respectively. Our findings revealed shorter response times for large-sized stimuli than for small-sized stimuli only for greater angular disparities, suggesting that the more unfamiliar the orientations of the bodily stimuli, the more stimuli size affected mental processing. Importantly, when comparing size transformation times, results revealed different patterns of size transformation times as a function of angular disparity between object-based and egocentric transformations. This indicates that mental size transformation and mental rotation proceed differently depending on the mental rotation strategy used. These findings are discussed with respect to the different spatial manipulations involved during object-based and egocentric transformations.
Interocular induction of illusory size perception.
Song, Chen; Schwarzkopf, D Samuel; Rees, Geraint
2011-03-11
The perceived size of objects not only depends on their physical size but also on the surroundings in which they appear. For example, an object surrounded by small items looks larger than a physically identical object surrounded by big items (Ebbinghaus illusion), and a physically identical but distant object looks larger than an object that appears closer in space (Ponzo illusion). Activity in human primary visual cortex (V1) reflects the perceived rather than the physical size of objects, indicating an involvement of V1 in illusory size perception. Here we investigate the role of eye-specific signals in two common size illusions in order to provide further information about the mechanisms underlying illusory size perception. We devised stimuli so that an object and its spatial context associated with illusory size perception could be presented together to one eye or separately to two eyes. We found that the Ponzo illusion had an equivalent magnitude whether the objects and contexts were presented to the same or different eyes, indicating that it may be largely mediated by binocular neurons. In contrast, the Ebbinghaus illusion became much weaker when objects and their contexts were presented to different eyes, indicating important contributions to the illusion from monocular neurons early in the visual pathway. Our findings show that two well-known size illusions - the Ponzo illusion and the Ebbinghaus illusion - are mediated by different neuronal populations, and suggest that the underlying neural mechanisms associated with illusory size perception differ and can be dependent on monocular channels in the early visual pathway.
Size Constancy in Bat Biosonar? Perceptual Interaction of Object Aperture and Distance
Heinrich, Melina; Wiegrebe, Lutz
2013-01-01
Perception and encoding of object size is an important feature of sensory systems. In the visual system object size is encoded by the visual angle (visual aperture) on the retina, but the aperture depends on the distance of the object. As object distance is not unambiguously encoded in the visual system, higher computational mechanisms are needed. This phenomenon is termed “size constancy”. It is assumed to reflect an automatic re-scaling of visual aperture with perceived object distance. Recently, it was found that in echolocating bats, the ‘sonar aperture’, i.e., the range of angles from which sound is reflected from an object back to the bat, is unambiguously perceived and neurally encoded. Moreover, it is well known that object distance is accurately perceived and explicitly encoded in bat sonar. Here, we addressed size constancy in bat biosonar, recruiting virtual-object techniques. Bats of the species Phyllostomus discolor learned to discriminate two simple virtual objects that only differed in sonar aperture. Upon successful discrimination, test trials were randomly interspersed using virtual objects that differed in both aperture and distance. It was tested whether the bats spontaneously assigned absolute width information to these objects by combining distance and aperture. The results showed that while the isolated perceptual cues encoding object width, aperture, and distance were all perceptually well resolved by the bats, the animals did not assign absolute width information to the test objects. This lack of sonar size constancy may result from the bats relying on different modalities to extract size information at different distances. Alternatively, it is conceivable that familiarity with a behaviorally relevant, conspicuous object is required for sonar size constancy, as it has been argued for visual size constancy. Based on the current data, it appears that size constancy is not necessarily an essential feature of sonar perception in bats. PMID:23630598
Size constancy in bat biosonar? Perceptual interaction of object aperture and distance.
Heinrich, Melina; Wiegrebe, Lutz
2013-01-01
Perception and encoding of object size is an important feature of sensory systems. In the visual system object size is encoded by the visual angle (visual aperture) on the retina, but the aperture depends on the distance of the object. As object distance is not unambiguously encoded in the visual system, higher computational mechanisms are needed. This phenomenon is termed "size constancy". It is assumed to reflect an automatic re-scaling of visual aperture with perceived object distance. Recently, it was found that in echolocating bats, the 'sonar aperture', i.e., the range of angles from which sound is reflected from an object back to the bat, is unambiguously perceived and neurally encoded. Moreover, it is well known that object distance is accurately perceived and explicitly encoded in bat sonar. Here, we addressed size constancy in bat biosonar, recruiting virtual-object techniques. Bats of the species Phyllostomus discolor learned to discriminate two simple virtual objects that only differed in sonar aperture. Upon successful discrimination, test trials were randomly interspersed using virtual objects that differed in both aperture and distance. It was tested whether the bats spontaneously assigned absolute width information to these objects by combining distance and aperture. The results showed that while the isolated perceptual cues encoding object width, aperture, and distance were all perceptually well resolved by the bats, the animals did not assign absolute width information to the test objects. This lack of sonar size constancy may result from the bats relying on different modalities to extract size information at different distances. Alternatively, it is conceivable that familiarity with a behaviorally relevant, conspicuous object is required for sonar size constancy, as it has been argued for visual size constancy. Based on the current data, it appears that size constancy is not necessarily an essential feature of sonar perception in bats.
Interocular induction of illusory size perception
2011-01-01
Background The perceived size of objects not only depends on their physical size but also on the surroundings in which they appear. For example, an object surrounded by small items looks larger than a physically identical object surrounded by big items (Ebbinghaus illusion), and a physically identical but distant object looks larger than an object that appears closer in space (Ponzo illusion). Activity in human primary visual cortex (V1) reflects the perceived rather than the physical size of objects, indicating an involvement of V1 in illusory size perception. Here we investigate the role of eye-specific signals in two common size illusions in order to provide further information about the mechanisms underlying illusory size perception. Results We devised stimuli so that an object and its spatial context associated with illusory size perception could be presented together to one eye or separately to two eyes. We found that the Ponzo illusion had an equivalent magnitude whether the objects and contexts were presented to the same or different eyes, indicating that it may be largely mediated by binocular neurons. In contrast, the Ebbinghaus illusion became much weaker when objects and their contexts were presented to different eyes, indicating important contributions to the illusion from monocular neurons early in the visual pathway. Conclusions Our findings show that two well-known size illusions - the Ponzo illusion and the Ebbinghaus illusion - are mediated by different neuronal populations, and suggest that the underlying neural mechanisms associated with illusory size perception differ and can be dependent on monocular channels in the early visual pathway. PMID:21396093
Stereoscopic shape discrimination is well preserved across changes in object size.
Norman, J Farley; Swindle, Jessica M; Jennings, L RaShae; Mullins, Elizabeth M; Beers, Amanda M
2009-06-01
A single experiment evaluated human observers' ability to discriminate the shape of solid objects that varied in size and orientation in depth. The object shapes were defined by binocular disparity, Lambertian shading, and texture. The object surfaces were smoothly curved and had naturalistic shapes, resembling those of water-smoothed granite rocks. On any given trial, two objects were presented that were either the same or different in terms of shape. When the "same" objects were presented, they differed in their orientation in depth by 25 degrees , 45 degrees , or 65 degrees . The observers were required to judge whether any given pair of objects was the "same" or "different" in terms of shape. The size of the objects was also varied by amounts up to +/-40% relative to the standard size. The observers' shape discrimination performance was strongly affected by the magnitude of the orientation changes in depth - thus, their performance was viewpoint dependent. In contrast, the observers' shape discrimination abilities were only slightly affected by changes in the overall size of the objects. It appears that human observers can recognize the three-dimensional shape of objects in a manner that is relatively independent of size.
Modeling of equilibrium hollow objects stabilized by electrostatics.
Mani, Ethayaraja; Groenewold, Jan; Kegel, Willem K
2011-05-18
The equilibrium size of two largely different kinds of hollow objects behave qualitatively differently with respect to certain experimental conditions. Yet, we show that they can be described within the same theoretical framework. The objects we consider are 'minivesicles' of ionic and nonionic surfactant mixtures, and shells of Keplerate-type polyoxometalates. The finite-size of the objects in both systems is manifested by electrostatic interactions. We emphasize the importance of constant charge and constant potential boundary conditions. Taking these conditions into account, indeed, leads to the experimentally observed qualitatively different behavior of the equilibrium size of the objects.
Size-weight illusion and anticipatory grip force scaling following unilateral cortical brain lesion.
Li, Yong; Randerath, Jennifer; Goldenberg, Georg; Hermsdörfer, Joachim
2011-04-01
The prediction of object weight from its size is an important prerequisite of skillful object manipulation. Grip and load forces anticipate object size during early phases of lifting an object. A mismatch between predicted and actual weight when two different sized objects have the same weight results in the size-weight illusion (SWI), the small object feeling heavier. This study explores whether lateralized brain lesions in patients with or without apraxia alter the size-weight illusion and impair anticipatory finger force scaling. Twenty patients with left brain damage (LBD, 10 with apraxia, 10 without apraxia), ten patients with right brain damage (RBD), and matched control subjects lifted two different-sized boxes in alternation. All subjects experienced a similar size-weight illusion. The anticipatory force scaling of all groups was in correspondence with the size cue: higher forces and force rates were applied to the big box and lower forces and force rates to the small box during the first lifts. Within few lifts, forces were scaled to actual object weight. Despite the lack of significant differences at group level, 5 out of 20 LBD patients showed abnormal predictive scaling of grip forces. They differed from the LBD patients with normal predictive scaling by a greater incidence of posterior occipito-parietal lesions but not by a greater incidence of apraxia. The findings do not support a more general role for the motor-dominant left hemisphere, or an influence of apraxia per se, in the scaling of finger force according to object properties. However, damage in the vicinity of the parietal-occipital junction may be critical for deriving predictions of weight from size. Copyright © 2011 Elsevier Ltd. All rights reserved.
An Integrated Knowledge Framework to Characterize and Scaffold Size and Scale Cognition (FS2C)
NASA Astrophysics Data System (ADS)
Magana, Alejandra J.; Brophy, Sean P.; Bryan, Lynn A.
2012-09-01
Size and scale cognition is a critical ability associated with reasoning with concepts in different disciplines of science, technology, engineering, and mathematics. As such, researchers and educators have identified the need for young learners and their educators to become scale-literate. Informed by developmental psychology literature and recent findings in nanoscale science and engineering education, we propose an integrated knowledge framework for characterizing and scaffolding size and scale cognition called the FS2C framework. Five ad hoc assessment tasks were designed informed by the FS2C framework with the goal of identifying participants' understandings of size and scale. Findings identified participants' difficulties to discern different sizes of microscale and nanoscale objects and a low level of sophistication on identifying scale worlds among participants. Results also identified that as bigger the difference between the sizes of the objects is, the more difficult was for participants to identify how many times an object is bigger or smaller than another one. Similarly, participants showed difficulties to estimate approximate sizes of sub-macroscopic objects as well as a difficulty for participants to estimate the size of very large objects. Participants' accurate location of objects on a logarithmic scale was also challenging.
A blind human expert echolocator shows size constancy for objects perceived by echoes.
Milne, Jennifer L; Anello, Mimma; Goodale, Melvyn A; Thaler, Lore
2015-01-01
Some blind humans make clicking noises with their mouth and use the reflected echoes to perceive objects and surfaces. This technique can operate as a crude substitute for vision, allowing human echolocators to perceive silent, distal objects. Here, we tested if echolocation would, like vision, show size constancy. To investigate this, we asked a blind expert echolocator (EE) to echolocate objects of different physical sizes presented at different distances. The EE consistently identified the true physical size of the objects independent of distance. In contrast, blind and blindfolded sighted controls did not show size constancy, even when encouraged to use mouth clicks, claps, or other signals. These findings suggest that size constancy is not a purely visual phenomenon, but that it can operate via an auditory-based substitute for vision, such as human echolocation.
Drawing skill is related to the efficiency of encoding object structure.
Perdreau, Florian; Cavanagh, Patrick
2014-01-01
Accurate drawing calls on many skills beyond simple motor coordination. A good internal representation of the target object's structure is necessary to capture its proportion and shape in the drawing. Here, we assess two aspects of the perception of object structure and relate them to participants' drawing accuracy. First, we assessed drawing accuracy by computing the geometrical dissimilarity of their drawing to the target object. We then used two tasks to evaluate the efficiency of encoding object structure. First, to examine the rate of temporal encoding, we varied presentation duration of a possible versus impossible test object in the fovea using two different test sizes (8° and 28°). More skilled participants were faster at encoding an object's structure, but this difference was not affected by image size. A control experiment showed that participants skilled in drawing did not have a general advantage that might have explained their faster processing for object structure. Second, to measure the critical image size for accurate classification in the periphery, we varied image size with possible versus impossible object tests centered at two different eccentricities (3° and 8°). More skilled participants were able to categorise object structure at smaller sizes, and this advantage did not change with eccentricity. A control experiment showed that the result could not be attributed to differences in visual acuity, leaving attentional resolution as a possible explanation. Overall, we conclude that drawing accuracy is related to faster encoding of object structure and better access to crowded details.
Drawing skill is related to the efficiency of encoding object structure
Perdreau, Florian; Cavanagh, Patrick
2014-01-01
Accurate drawing calls on many skills beyond simple motor coordination. A good internal representation of the target object's structure is necessary to capture its proportion and shape in the drawing. Here, we assess two aspects of the perception of object structure and relate them to participants' drawing accuracy. First, we assessed drawing accuracy by computing the geometrical dissimilarity of their drawing to the target object. We then used two tasks to evaluate the efficiency of encoding object structure. First, to examine the rate of temporal encoding, we varied presentation duration of a possible versus impossible test object in the fovea using two different test sizes (8° and 28°). More skilled participants were faster at encoding an object's structure, but this difference was not affected by image size. A control experiment showed that participants skilled in drawing did not have a general advantage that might have explained their faster processing for object structure. Second, to measure the critical image size for accurate classification in the periphery, we varied image size with possible versus impossible object tests centered at two different eccentricities (3° and 8°). More skilled participants were able to categorise object structure at smaller sizes, and this advantage did not change with eccentricity. A control experiment showed that the result could not be attributed to differences in visual acuity, leaving attentional resolution as a possible explanation. Overall, we conclude that drawing accuracy is related to faster encoding of object structure and better access to crowded details. PMID:25469216
Differential effects of delay upon visually and haptically guided grasping and perceptual judgments.
Pettypiece, Charles E; Culham, Jody C; Goodale, Melvyn A
2009-05-01
Experiments with visual illusions have revealed a dissociation between the systems that mediate object perception and those responsible for object-directed action. More recently, an experiment on a haptic version of the visual size-contrast illusion has provided evidence for the notion that the haptic modality shows a similar dissociation when grasping and estimating the size of objects in real-time. Here we present evidence suggesting that the similarities between the two modalities begin to break down once a delay is introduced between when people feel the target object and when they perform the grasp or estimation. In particular, when grasping after a delay in a haptic paradigm, people scale their grasps differently when the target is presented with a flanking object of a different size (although the difference does not reflect a size-contrast effect). When estimating after a delay, however, it appears that people ignore the size of the flanking objects entirely. This does not fit well with the results commonly found in visual experiments. Thus, introducing a delay reveals important differences in the way in which haptic and visual memories are stored and accessed.
A Familiar-Size Stroop Effect: Real-World Size Is an Automatic Property of Object Representation
ERIC Educational Resources Information Center
Konkle, Talia; Oliva, Aude
2012-01-01
When we recognize an object, do we automatically know how big it is in the world? We employed a Stroop-like paradigm, in which two familiar objects were presented at different visual sizes on the screen. Observers were faster to indicate which was bigger or smaller on the screen when the real-world size of the objects was congruent with the visual…
SU-F-207-16: CT Protocols Optimization Using Model Observer
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tseng, H; Fan, J; Kupinski, M
2015-06-15
Purpose: To quantitatively evaluate the performance of different CT protocols using task-based measures of image quality. This work studies the task of size and the contrast estimation of different iodine concentration rods inserted in head- and body-sized phantoms using different imaging protocols. These protocols are designed to have the same dose level (CTDIvol) but using different X-ray tube voltage settings (kVp). Methods: Different concentrations of iodine objects inserted in a head size phantom and a body size phantom are imaged on a 64-slice commercial CT scanner. Scanning protocols with various tube voltages (80, 100, and 120 kVp) and current settingsmore » are selected, which output the same absorbed dose level (CTDIvol). Because the phantom design (size of the iodine objects, the air gap between the inserted objects and the phantom) is not ideal for a model observer study, the acquired CT images are used to generate simulation images with four different sizes and five different contracts iodine objects. For each type of the objects, 500 images (100 x 100 pixels) are generated for the observer study. The observer selected in this study is the channelized scanning linear observer which could be applied to estimate the size and the contrast. The figure of merit used is the correct estimation ratio. The mean and the variance are estimated by the shuffle method. Results: The results indicate that the protocols with 100 kVp tube voltage setting provides the best performance for iodine insert size and contrast estimation for both head and body phantom cases. Conclusion: This work presents a practical and robust quantitative approach using channelized scanning linear observer to study contrast and size estimation performance from different CT protocols. Different protocols at same CTDIvol setting could Result in different image quality performance. The relationship between the absorbed dose and the diagnostic image quality is not linear.« less
Size-Sensitive Perceptual Representations Underlie Visual and Haptic Object Recognition
Craddock, Matt; Lawson, Rebecca
2009-01-01
A variety of similarities between visual and haptic object recognition suggests that the two modalities may share common representations. However, it is unclear whether such common representations preserve low-level perceptual features or whether transfer between vision and haptics is mediated by high-level, abstract representations. Two experiments used a sequential shape-matching task to examine the effects of size changes on unimodal and crossmodal visual and haptic object recognition. Participants felt or saw 3D plastic models of familiar objects. The two objects presented on a trial were either the same size or different sizes and were the same shape or different but similar shapes. Participants were told to ignore size changes and to match on shape alone. In Experiment 1, size changes on same-shape trials impaired performance similarly for both visual-to-visual and haptic-to-haptic shape matching. In Experiment 2, size changes impaired performance on both visual-to-haptic and haptic-to-visual shape matching and there was no interaction between the cost of size changes and direction of transfer. Together the unimodal and crossmodal matching results suggest that the same, size-specific perceptual representations underlie both visual and haptic object recognition, and indicate that crossmodal memory for objects must be at least partly based on common perceptual representations. PMID:19956685
Effects of varying gravity levels in parabolic flight on the size-mass illusion.
Clément, Gilles
2014-01-01
When an observer lifts two objects with the same weight but different sizes, the smaller object is consistently reported to feel heavier than the larger object even after repeated trials. Here we explored the effect of reduced and increased gravity on this perceptual size-mass illusion. Experiments were performed on board the CNES Airbus A300 Zero-G during parabolic flights eliciting repeated exposures to short periods of zero g, 0.16 g, 0.38 g, one g, and 1.8 g. Subjects were asked to assess perceived heaviness by actively oscillating objects with various sizes and masses. The results showed that a perceptual size-mass illusion was clearly present at all gravity levels. During the oscillations, the peak arm acceleration varied as a function of the gravity level, irrespective of the mass and size of the objects. In other words we did not observe a sensorimotor size-mass illusion. These findings confirm dissociation between the sensorimotor and perceptual systems for determining object mass. In addition, they suggest that astronauts on the Moon or Mars with the eyes closed will be able to accurately determine the relative difference in mass between objects.
Effects of Varying Gravity Levels in Parabolic Flight on the Size-Mass Illusion
Clément, Gilles
2014-01-01
When an observer lifts two objects with the same weight but different sizes, the smaller object is consistently reported to feel heavier than the larger object even after repeated trials. Here we explored the effect of reduced and increased gravity on this perceptual size-mass illusion. Experiments were performed on board the CNES Airbus A300 Zero-G during parabolic flights eliciting repeated exposures to short periods of zero g, 0.16 g, 0.38 g, one g, and 1.8 g. Subjects were asked to assess perceived heaviness by actively oscillating objects with various sizes and masses. The results showed that a perceptual size-mass illusion was clearly present at all gravity levels. During the oscillations, the peak arm acceleration varied as a function of the gravity level, irrespective of the mass and size of the objects. In other words we did not observe a sensorimotor size-mass illusion. These findings confirm dissociation between the sensorimotor and perceptual systems for determining object mass. In addition, they suggest that astronauts on the Moon or Mars with the eyes closed will be able to accurately determine the relative difference in mass between objects. PMID:24901519
NASA Technical Reports Server (NTRS)
Xu, Kuan-Man; Wong, Takmeng; Wielicki, Bruce A.; Parker, Lindsay
2006-01-01
Three boundary-layer cloud object types, stratus, stratocumulus and cumulus, that occurred over the Pacific Ocean during January-August 1998, are identified from the CERES (Clouds and the Earth s Radiant Energy System) single scanner footprint (SSF) data from the TRMM (Tropical Rainfall Measuring Mission) satellite. This study emphasizes the differences and similarities in the characteristics of each cloud-object type between the tropical and subtropical regions and among different size categories and among small geographic areas. Both the frequencies of occurrence and statistical distributions of cloud physical properties are analyzed. In terms of frequencies of occurrence, stratocumulus clouds dominate the entire boundary layer cloud population in all regions and among all size categories. Stratus clouds are more prevalent in the subtropics and near the coastal regions, while cumulus clouds are relatively prevalent over open ocean and the equatorial regions, particularly, within the small size categories. The largest size category of stratus cloud objects occurs more frequently in the subtropics than in the tropics and has much larger average size than its cumulus and stratocumulus counterparts. Each of the three cloud object types exhibits small differences in statistical distributions of cloud optical depth, liquid water path, TOA albedo and perhaps cloud-top height, but large differences in those of cloud-top temperature and OLR between the tropics and subtropics. Differences in the sea surface temperature (SST) distributions between the tropics and subtropics influence some of the cloud macrophysical properties, but cloud microphysical properties and albedo for each cloud object type are likely determined by (local) boundary-layer dynamics and structures. Systematic variations of cloud optical depth, TOA albedo, cloud-top height, OLR and SST with cloud object sizes are pronounced for the stratocumulus and stratus types, which are related to systematic variations of the strength of inversion with cloud object sizes, produced by large-scale subsidence. The differences in cloud macrophysical properties over small regions are significantly larger than those of cloud microphysical properties and TOA albedo, suggesting a greater control of (local) large-scale dynamics and other factors on cloud object properties. When the three cloud object types are combined, the relative population among the three types is the most important factor for determining the cloud object properties in a Pacific transect where the transition of boundary-layer cloud types takes place.
Event-related potentials during word mapping to object shape predict toddlers' vocabulary size
Borgström, Kristina; Torkildsen, Janne von Koss; Lindgren, Magnus
2015-01-01
What role does attention to different object properties play in early vocabulary development? This longitudinal study using event-related potentials in combination with behavioral measures investigated 20- and 24-month-olds' (n = 38; n = 34; overlapping n = 24) ability to use object shape and object part information in word-object mapping. The N400 component was used to measure semantic priming by images containing shape or detail information. At 20 months, the N400 to words primed by object shape varied in topography and amplitude depending on vocabulary size, and these differences predicted productive vocabulary size at 24 months. At 24 months, when most of the children had vocabularies of several hundred words, the relation between vocabulary size and the N400 effect in a shape context was weaker. Detached object parts did not function as word primes regardless of age or vocabulary size, although the part-objects were identified behaviorally. The behavioral measure, however, also showed relatively poor recognition of the part-objects compared to the shape-objects. These three findings provide new support for the link between shape recognition and early vocabulary development. PMID:25762957
Nordlöf, Hasse; Wijk, Katarina; Westergren, Karl-Erik
2015-01-01
BACKGROUND: Earlier studies suggest that the quality of handling occupational health and safety (OHS) activities differs between companies of different sizes. Company size is a proxy variable for other variables affecting OHS performance. OBJECTIVE: The objective of this study was to investigate if there is an association between company size and perceptions of work environment prioritizations. METHODS: Data from 106 small- and medium-sized Swedish manufacturing companies was collected. One manager and one safety delegate at each company rated different aspects of their companies’ work environment prioritizations with a 43-item questionnaire. Ratings were aggregated to a summary statistic for each company before analysis. RESULTS: No significant differences in perceptions of priority were found to be associated with company sizes. This is in contrast to earlier studies of objective differences. The respondents in small companies, however, showed significantly greater consensus in their ratings. CONCLUSIONS: Company size does not appear to be associated with perceptions of work environment prioritizations. Company size is an important proxy variable to study in order to understand what factors enable and obstruct safe and healthy workplaces. The work presented here should be viewed as an initial exploration to serve as direction for future academic work. PMID:26409368
A possible divot in the Kuiper belt's scattered-object size distribution
NASA Astrophysics Data System (ADS)
Shankman, C.; Kavelaars, J.; Gladman, B.; Petit, J.
2014-07-01
The formation and evolution history of the Solar System, while not directly accessible, has measurable signatures in the present-day size distributions of the Trans-Neptunian Object (TNO) populations. The form of the size distribution is modelled as a power law with number going as size to some characteristic slope. Recent works have shown that a single power law does not match the observations across all sizes; the power law breaks to a different form [1, 2, 3]. The large- size objects record the accretion history, while the small-size objects record the collision history. The changes of size-distribution shape and slope as one moves from 'large' to 'medium' to 'small' KBOs are the signature needed to constrain the formation and collision history of the Solar System. The scattering TNOs are those TNOs undergoing strong (scattering) interactions Neptune. The scattering objects can come to pericentre in the giant planet region. This close-in pericentre passage allows for the observation of smaller objects, and thus for the constraint of the small-size end of the size distribution. Our recent analysis of the Canada France Ecliptic Plane Survey's (CFEPS) scattering objects revealed an exciting potential form for the scattering object size distribution - a divot (see Figure). Our divot (a sharp drop in the number of objects per unit size which then returns at a potentially different slope) matches our observations well and can simultaneously explain observed features in other inclined (so-called "hot") Kuiper Belt populations. In this scenario all of the hot populations would share the same source and have been implanted in the outer solar system through scattering processes. If confirmed, our divot would represent a new exciting paradigm for the formation history of the Kuiper Belt. Here we present the results of an extension of our previous work to include a new, deeper, Kuiper Belt survey. By the addition of two new faint scattering objects from this survey which, in tandem with the full characterizations of the survey's biases (acting like non- detections limits), we better constrain the form of the scattering object size distribution.
Bruno, Nicola; Uccelli, Stefano; Viviani, Eva; de'Sperati, Claudio
2016-10-01
According to a previous report, the visual coding of size does not obey Weber's law when aimed at guiding a grasp (Ganel et al., 2008a). This result has been interpreted as evidence for a fundamental difference between sensory processing in vision-for-perception, which needs to compress a wide range of physical objects to a restricted range of percepts, and vision-for-action when applied to the much narrower range of graspable and reachable objects. We compared finger aperture in a motor task (precision grip) and perceptual task (cross modal matching or "manual estimation" of the object's size). Crucially, we tested the whole range of graspable objects. We report that both grips and estimations clearly violate Weber's law with medium-to-large objects, but are essentially consistent with Weber's law with smaller objects. These results differ from previous characterizations of perception-action dissociations in the precision of representations of object size. Implications for current functional interpretations of the dorsal and ventral processing streams in the human visual system are discussed. Copyright © 2016 Elsevier Ltd. All rights reserved.
Perception of the average size of multiple objects in chimpanzees (Pan troglodytes).
Imura, Tomoko; Kawakami, Fumito; Shirai, Nobu; Tomonaga, Masaki
2017-08-30
Humans can extract statistical information, such as the average size of a group of objects or the general emotion of faces in a crowd without paying attention to any individual object or face. To determine whether summary perception is unique to humans, we investigated the evolutional origins of this ability by assessing whether chimpanzees, which are closely related to humans, can also determine the average size of multiple visual objects. Five chimpanzees and 18 humans were able to choose the array in which the average size was larger, when presented with a pair of arrays, each containing 12 circles of different or the same sizes. Furthermore, both species were more accurate in judging the average size of arrays consisting of 12 circles of different or the same sizes than they were in judging the average size of arrays consisting of a single circle. Our findings could not be explained by the use of a strategy in which the chimpanzee detected the largest or smallest circle among those in the array. Our study provides the first evidence that chimpanzees can perceive the average size of multiple visual objects. This indicates that the ability to compute the statistical properties of a complex visual scene is not unique to humans, but is shared between both species. © 2017 The Authors.
Perception of the average size of multiple objects in chimpanzees (Pan troglodytes)
Kawakami, Fumito; Shirai, Nobu; Tomonaga, Masaki
2017-01-01
Humans can extract statistical information, such as the average size of a group of objects or the general emotion of faces in a crowd without paying attention to any individual object or face. To determine whether summary perception is unique to humans, we investigated the evolutional origins of this ability by assessing whether chimpanzees, which are closely related to humans, can also determine the average size of multiple visual objects. Five chimpanzees and 18 humans were able to choose the array in which the average size was larger, when presented with a pair of arrays, each containing 12 circles of different or the same sizes. Furthermore, both species were more accurate in judging the average size of arrays consisting of 12 circles of different or the same sizes than they were in judging the average size of arrays consisting of a single circle. Our findings could not be explained by the use of a strategy in which the chimpanzee detected the largest or smallest circle among those in the array. Our study provides the first evidence that chimpanzees can perceive the average size of multiple visual objects. This indicates that the ability to compute the statistical properties of a complex visual scene is not unique to humans, but is shared between both species. PMID:28835550
Form features provide a cue to the angular velocity of rotating objects.
Blair, Christopher David; Goold, Jessica; Killebrew, Kyle; Caplovitz, Gideon Paul
2014-02-01
As an object rotates, each location on the object moves with an instantaneous linear velocity, dependent upon its distance from the center of rotation, whereas the object as a whole rotates with a fixed angular velocity. Does the perceived rotational speed of an object correspond to its angular velocity, linear velocities, or some combination of the two? We had observers perform relative speed judgments of different-sized objects, as changing the size of an object changes the linear velocity of each location on the object's surface, while maintaining the object's angular velocity. We found that the larger a given object is, the faster it is perceived to rotate. However, the observed relationships between size and perceived speed cannot be accounted for simply by size-related changes in linear velocity. Further, the degree to which size influences perceived rotational speed depends on the shape of the object. Specifically, perceived rotational speeds of objects with corners or regions of high-contour curvature were less affected by size. The results suggest distinct contour features, such as corners or regions of high or discontinuous contour curvature, provide cues to the angular velocity of a rotating object. PsycINFO Database Record (c) 2014 APA, all rights reserved.
Testing effects in visual short-term memory: The case of an object's size.
Makovski, Tal
2018-05-29
In many daily activities, we need to form and retain temporary representations of an object's size. Typically, such visual short-term memory (VSTM) representations follow perception and are considered reliable. Here, participants were asked to hold in mind a single simple object for a short duration and to reproduce its size by adjusting the length and width of a test probe. Experiment 1 revealed two powerful findings: First, similar to a recently reported perceptual illusion, participants greatly overestimated the size of open objects - ones with missing boundaries - relative to the same-size fully closed objects. This finding confirms that object boundaries are critical for size perception and memory. Second, and in contrast to perception, even the size of the closed objects was largely overestimated. Both inflation effects were substantial and were replicated and extended in Experiments 2-5. Experiments 6-8 used a different testing procedure to examine whether the overestimation effects are due to inflation of size in VSTM representations or to biases introduced during the reproduction phase. These data showed that while the overestimation of the open objects was repeated, the overestimation of the closed objects was not. Taken together, these findings suggest that similar to perception, only the size representation of open objects is inflated in VSTM. Importantly, they demonstrate the considerable impact of the testing procedure on VSTM tasks and further question the use of reproduction procedures for measuring VSTM.
Mid-level perceptual features distinguish objects of different real-world sizes.
Long, Bria; Konkle, Talia; Cohen, Michael A; Alvarez, George A
2016-01-01
Understanding how perceptual and conceptual representations are connected is a fundamental goal of cognitive science. Here, we focus on a broad conceptual distinction that constrains how we interact with objects--real-world size. Although there appear to be clear perceptual correlates for basic-level categories (apples look like other apples, oranges look like other oranges), the perceptual correlates of broader categorical distinctions are largely unexplored, i.e., do small objects look like other small objects? Because there are many kinds of small objects (e.g., cups, keys), there may be no reliable perceptual features that distinguish them from big objects (e.g., cars, tables). Contrary to this intuition, we demonstrated that big and small objects have reliable perceptual differences that can be extracted by early stages of visual processing. In a series of visual search studies, participants found target objects faster when the distractor objects differed in real-world size. These results held when we broadly sampled big and small objects, when we controlled for low-level features and image statistics, and when we reduced objects to texforms--unrecognizable textures that loosely preserve an object's form. However, this effect was absent when we used more basic textures. These results demonstrate that big and small objects have reliably different mid-level perceptual features, and suggest that early perceptual information about broad-category membership may influence downstream object perception, recognition, and categorization processes. (c) 2015 APA, all rights reserved).
Form features provide a cue to the angular velocity of rotating objects
Blair, Christopher David; Goold, Jessica; Killebrew, Kyle; Caplovitz, Gideon Paul
2013-01-01
As an object rotates, each location on the object moves with an instantaneous linear velocity dependent upon its distance from the center of rotation, while the object as a whole rotates with a fixed angular velocity. Does the perceived rotational speed of an object correspond to its angular velocity, linear velocities, or some combination of the two? We had observers perform relative speed judgments of different sized objects, as changing the size of an object changes the linear velocity of each location on the object’s surface, while maintaining the object’s angular velocity. We found that the larger a given object is, the faster it is perceived to rotate. However, the observed relationships between size and perceived speed cannot be accounted for simply by size-related changes in linear velocity. Further, the degree to which size influences perceived rotational speed depends on the shape of the object. Specifically, perceived rotational speeds of objects with corners or regions of high contour curvature were less affected by size. The results suggest distinct contour features, such as corners or regions of high or discontinuous contour curvature, provide cues to the angular velocity of a rotating object. PMID:23750970
How Weight Affects the Perceived Spacing between the Thumb and Fingers during Grasping
Butler, Annie A.; Héroux, Martin E.; Gandevia, Simon C.
2015-01-01
We know much about mechanisms determining the perceived size and weight of lifted objects, but little about how these properties of size and weight affect the body representation (e.g. grasp aperture of the hand). Without vision, subjects (n = 16) estimated spacing between fingers and thumb (perceived grasp aperture) while lifting canisters of the same width (6.6cm) but varied weights (300, 600, 900, and 1200 g). Lifts were performed by movement of either the wrist, elbow or shoulder to examine whether lifting with different muscle groups affects the judgement of grasp aperture. Results for perceived grasp aperture were compared with changes in perceived weight of objects of different sizes (5.2, 6.6, and 10 cm) but the same weight (600 g). When canisters of the same width but different weights were lifted, perceived grasp aperture decreased 4.8% [2.2 ‒ 7.4] (mean [95% CI]; P < 0.001) from the lightest to the heaviest canister, no matter how they were lifted. For objects of the same weight but different widths, perceived weight decreased 42.3% [38.2 ‒ 46.4] from narrowest to widest (P < 0.001), as expected from the size-weight illusion. Thus, despite a highly distorted perception of the weight of objects based on their size, we conclude that proprioceptive afferents maintain a reasonably stable perception of the aperture of the grasping hand over a wide range of object weights. Given the small magnitude of this ‘weight-grasp aperture’ illusion, we propose the brain has access to a relatively stable ‘perceptual ruler’ to aid the manipulation of different objects. PMID:25996760
Nordlöf, Hasse; Wijk, Katarina; Westergren, Karl-Erik
2015-01-01
Earlier studies suggest that the quality of handling occupational health and safety (OHS) activities differs between companies of different sizes. Company size is a proxy variable for other variables affecting OHS performance. The objective of this study was to investigate if there is an association between company size and perceptions of work environment prioritizations. Data from 106 small- and medium-sized Swedish manufacturing companies was collected. One manager and one safety delegate at each company rated different aspects of their companies' work environment prioritizations with a 43-item questionnaire. Ratings were aggregated to a summary statistic for each company before analysis. No significant differences in perceptions of priority were found to be associated with company sizes. This is in contrast to earlier studies of objective differences. The respondents in small companies, however, showed significantly greater consensus in their ratings. Company size does not appear to be associated with perceptions of work environment prioritizations. Company size is an important proxy variable to study in order to understand what factors enable and obstruct safe and healthy workplaces. The work presented here should be viewed as an initial exploration to serve as direction for future academic work.
Perception-action dissociation generalizes to the size-inertia illusion.
Platkiewicz, Jonathan; Hayward, Vincent
2014-04-01
Two objects of similar visual aspects and of equal mass, but of different sizes, generally do not elicit the same percept of heaviness in humans. The larger object is consistently felt to be lighter than the smaller, an effect known as the "size-weight illusion." When asked to repeatedly lift the two objects, the grip forces were observed to adapt rapidly to the true object weight while the size-weight illusion persisted, a phenomenon interpreted as a dissociation between perception and action. We investigated whether the same phenomenon can be observed if the mass of an object is available to participants through inertial rather than gravitational cues and if the number and statistics of the stimuli is such that participants cannot remember each individual stimulus. We compared the responses of 10 participants in 2 experimental conditions, where they manipulated 33 objects having uncorrelated masses and sizes, supported by a frictionless, air-bearing slide that could be oriented vertically or horizontally. We also analyzed the participants' anticipatory motor behavior by measuring the grip force before motion onset. We found that the perceptual illusory effect was quantitatively the same in the two conditions and observed that both visual size and haptic mass had a negligible effect on the anticipatory gripping control of the participants in the gravitational and inertial conditions, despite the enormous differences in the mechanics of the two conditions and the large set of uncorrelated stimuli.
Overestimation of the Projected Size of Objects on the Surface of Mirrors and Windows
ERIC Educational Resources Information Center
Lawson, Rebecca; Bertamini, Marco; Liu, Dan
2007-01-01
Four experiments investigated judgments of the size of projections of objects on the glass surface of mirrors and windows. The authors tested different ways of explaining the task to overcome the difficulty that people had in understanding what the projection was, and they varied the distance of the observer and the object to the mirror or window…
Li, Yong; Randerath, Jennifer; Bauer, Hans; Marquardt, Christian; Goldenberg, Georg; Hermsdörfer, Joachim
2009-01-03
When we manipulate familiar objects in our daily life, our grip force anticipates the physical demands right from the moment of contact with the object, indicating the existence of a memory for relevant object properties. This study explores the formation and consolidation of the memory processes that associate either familiar (size) or arbitrary object features (color) with object weight. In the general task, participants repetitively lifted two differently weighted objects (580 and 280 g) in a pseudo-random order. Forty young healthy adults participated in this study and were randomly distributed into four groups: Color Cue Single task (CCS, blue and red, 9.8(3)cm(3)), Color Cue Dual task (CCD), No Cue (NC) and Size Cue (SC, 9.8(3) and 6(3)cm(3)) group. All groups performed a repetitive precision grasp-lift task and were retested with the same protocol after a 5-min pause. The CCD group was also required to simultaneously perform a memory task during each lift of differently weighted objects coded by color. The results show that groups lifting objects with arbitrary or familiar features successfully formed the association between object weight and manipulated object features and incorporated this into grip force programming, as observed in the different scaling of grip force and grip force rate for different object weights. An arbitrary feature, i.e., color, can be sufficiently associated with object weight, however with less strength than the familiar feature of size. The simultaneous memory task impaired anticipatory force scaling during repetitive object lifting but did not jeopardize the learning process and the consolidation of the associative memory.
Optical digitizing and strategies to combine different views of an optical sensor
NASA Astrophysics Data System (ADS)
Duwe, Hans P.
1997-09-01
Non-contact digitization of objects and surfaces with optical sensors based on fringe or pattern projection in combination with a CCD-camera allows a representation of surfaces with pointclouds equals x, y, z data points. To digitize the total surface of an object, it is necessary to combine the different measurement data obtained by the optical sensor from different views. Depending on the size of the object and the required accuracy of the measured data, different sensor set-ups with handling system or a combination of linear and rotation axes are described. Furthermore, strategies to match the overlapping pointclouds of a digitized object are introduced. This is very important especially for the digitization of large objects like 1:1 car models, etc. With different sensor sizes, it is possible to digitize small objects like teeth, crowns, inlays, etc. with an overall accuracy of 20 micrometer as well as large objects like car models, with a total accuracy of 0.5 mm. The various applications in the field of optical digitization are described.
Open-Filter Optical SSA Analysis Considerations
NASA Astrophysics Data System (ADS)
Lambert, J.
2016-09-01
Optical Space Situational Awareness (SSA) sensors used for space object detection and orbit refinement measurements are typically operated in an "open-filter" mode without any spectral filters to maximize sensitivity and signal-to-noise. These same optical brightness measurements are often also employed for size determination (e.g., for orbital debris), object correlation, and object status change. These functions, especially when performed using multiple sensors, are highly dependent on sensor calibration for measurement accuracy. Open-filter SSA sensors are traditionally calibrated against the cataloged visual magnitudes of solar-type stars which have similar spectral distributions as the illuminating source, the Sun. The stellar calibration is performed to a high level of accuracy, a few hundredths of a magnitude, by observing many stars over a range of elevation angles to determine sensor, telescope, and atmospheric effects. However, space objects have individual color properties which alter the reflected solar illumination producing spectral distributions which differ from those of the calibration stars. When the stellar calibrations are applied to the space object measurements, visual magnitude values are obtained which are systematically biased. These magnitudes combined with the unknown Bond albedos of the space objects result in systematically biased size determinations which will differ between sensors. Measurements of satellites of known sizes and surface materials have been analyzed to characterize these effects. The results have combined into standardized Bond albedos to correct the measured magnitudes into object sizes. However, the actual albedo values will vary between objects and represent a mean correction subject to some uncertainty. The objective of this discussion is to characterize the sensor spectral biases that are present in open-filter optical observations and examine the resulting brightness and albedo uncertainties that should accompany object size, correlation, or status change determinations, especially in the SSA analyses of individual space objects using data from multiple sensors.
ERIC Educational Resources Information Center
Dijker, Anton J. M.
2008-01-01
In order to examine the relative influence of size-based expectancies and social cues on the perceived weight of objects, two studies were performed, using equally weighing dolls differing in sex-related and age-related vulnerability or physical strength cues. To increase variation in perceived size, stimulus objects were viewed through optical…
Equal-magnitude size-weight illusions experienced within and between object categories.
Buckingham, Gavin; Goodale, Melvyn A; White, Justin A; Westwood, David A
2016-01-01
In the size-weight illusion (SWI), small objects feel heavier than larger objects of the same mass. This effect is typically thought to be a consequence of the lifter's expectation that the large object will outweigh the small object, because objects of the same type typically get heavier as they get larger. Here, we show that this perceptual effect can occur across object category, where there are no strong expectations about the correspondence between size and mass. One group of participants lifted same-colored large and small cubes with the same mass as one another, while another group lifted differently-colored large and small cubes with the same mass as one another. The group who lifted the same-colored cubes experienced a robust SWI and initially lifted the large object with more force than the small object. By contrast, the group who lifted the different-colored objects did so with equal initial forces on the first trial, but experienced just as strong an illusion as those who lifted the same-colored objects. These results demonstrate that color cues can selectively influence the application of fingertip force rates while not impacting at all upon the lifter's perception of object weight, highlighting a stark dissociation in how prior information affects perception and action.
Evaluation of attenuation and scatter correction requirements in small animal PET and SPECT imaging
NASA Astrophysics Data System (ADS)
Konik, Arda Bekir
Positron emission tomography (PET) and single photon emission tomography (SPECT) are two nuclear emission-imaging modalities that rely on the detection of high-energy photons emitted from radiotracers administered to the subject. The majority of these photons are attenuated (absorbed or scattered) in the body, resulting in count losses or deviations from true detection, which in turn degrades the accuracy of images. In clinical emission tomography, sophisticated correction methods are often required employing additional x-ray CT or radionuclide transmission scans. Having proven their potential in both clinical and research areas, both PET and SPECT are being adapted for small animal imaging. However, despite the growing interest in small animal emission tomography, little scientific information exists about the accuracy of these correction methods on smaller size objects, and what level of correction is required. The purpose of this work is to determine the role of attenuation and scatter corrections as a function of object size through simulations. The simulations were performed using Interactive Data Language (IDL) and a Monte Carlo based package, Geant4 application for emission tomography (GATE). In IDL simulations, PET and SPECT data acquisition were modeled in the presence of attenuation. A mathematical emission and attenuation phantom approximating a thorax slice and slices from real PET/CT data were scaled to 5 different sizes (i.e., human, dog, rabbit, rat and mouse). The simulated emission data collected from these objects were reconstructed. The reconstructed images, with and without attenuation correction, were compared to the ideal (i.e., non-attenuated) reconstruction. Next, using GATE, scatter fraction values (the ratio of the scatter counts to the total counts) of PET and SPECT scanners were measured for various sizes of NEMA (cylindrical phantoms representing small animals and human), MOBY (realistic mouse/rat model) and XCAT (realistic human model) digital phantoms. In addition, PET projection files for different sizes of MOBY phantoms were reconstructed in 6 different conditions including attenuation and scatter corrections. Selected regions were analyzed for these different reconstruction conditions and object sizes. Finally, real mouse data from the real version of the same small animal PET scanner we modeled in our simulations were analyzed for similar reconstruction conditions. Both our IDL and GATE simulations showed that, for small animal PET and SPECT, even the smallest size objects (˜2 cm diameter) showed ˜15% error when both attenuation and scatter were not corrected. However, a simple attenuation correction using a uniform attenuation map and object boundary obtained from emission data significantly reduces this error in non-lung regions (˜1% for smallest size and ˜6% for largest size). In lungs, emissions values were overestimated when only attenuation correction was performed. In addition, we did not observe any significant improvement between the uses of uniform or actual attenuation map (e.g., only ˜0.5% for largest size in PET studies). The scatter correction was not significant for smaller size objects, but became increasingly important for larger sizes objects. These results suggest that for all mouse sizes and most rat sizes, uniform attenuation correction can be performed using emission data only. For smaller sizes up to ˜ 4 cm, scatter correction is not required even in lung regions. For larger sizes if accurate quantization needed, additional transmission scan may be required to estimate an accurate attenuation map for both attenuation and scatter corrections.
Grasp with hand and mouth: a kinematic study on healthy subjects.
Gentilucci, M; Benuzzi, F; Gangitano, M; Grimaldi, S
2001-10-01
Neurons involved in grasp preparation with hand and mouth were previously recorded in the premotor cortex of monkey. The aim of the present kinematic study was to determine whether a unique planning underlies the act of grasping with hand and mouth in humans as well. In a set of four experiments, healthy subjects reached and grasped with the hand an object of different size while opening the mouth (experiments 1 and 3), or extending the other forearm (experiment 4), or the fingers of the other hand (experiment 5). In a subsequent set of three experiments, subjects grasped an object of different size with the mouth, while opening the fingers of the right hand (experiments 6-8). The initial kinematics of mouth and finger opening, but not of forearm extension, was affected by the size of the grasped object congruently with the size effect on initial grasp kinematics. This effect was due neither to visual presentation of the object, without the successive grasp motor act (experiment 2) nor to synchronism between finger and mouth opening (experiments 3, 7, and 8). In experiment 9 subjects grasped with the right hand an object of different size while pronouncing a syllable printed on the target. Mouth opening and sound production were affected by the grasped object size. The results of the present study are discussed according to the notion that in an action each motor act is prepared before the beginning of the motor sequence. Double grasp preparation can be used for successive motor acts on the same object as, for example, grasping food with the hand and ingesting it after bringing it to the mouth. We speculate that the circuits involved in double grasp preparation might have been the neural substrate where hand motor patterns used as primitive communication signs were transferred to mouth articulation system. This is in accordance with the hypothesis that Broca's area derives phylogenetically from the monkey premotor area where hand movements are controlled.
The objective assessment of experts' and novices' suturing skills using an image analysis program.
Frischknecht, Adam C; Kasten, Steven J; Hamstra, Stanley J; Perkins, Noel C; Gillespie, R Brent; Armstrong, Thomas J; Minter, Rebecca M
2013-02-01
To objectively assess suturing performance using an image analysis program and to provide validity evidence for this assessment method by comparing experts' and novices' performance. In 2009, the authors used an image analysis program to extract objective variables from digital images of suturing end products obtained during a previous study involving third-year medical students (novices) and surgical faculty and residents (experts). Variables included number of stitches, stitch length, total bite size, travel, stitch orientation, total bite-size-to-travel ratio, and symmetry across the incision ratio. The authors compared all variables between groups to detect significant differences and two variables (total bite-size-to-travel ratio and symmetry across the incision ratio) to ideal values. Five experts and 15 novices participated. Experts' and novices' performances differed significantly (P < .05) with large effect sizes attributable to experience (Cohen d > 0.8) for total bite size (P = .009, d = 1.5), travel (P = .045, d = 1.1), total bite-size-to-travel ratio (P < .0001, d = 2.6), stitch orientation (P = .014,d = 1.4), and symmetry across the incision ratio (P = .022, d = 1.3). The authors found that a simple computer algorithm can extract variables from digital images of a running suture and rapidly provide quantitative summative assessment feedback. The significant differences found between groups confirm that this system can discriminate between skill levels. This image analysis program represents a viable training tool for objectively assessing trainees' suturing, a foundational skill for many medical specialties.
Kinematic measurement from panned cinematography.
Gervais, P; Bedingfield, E W; Wronko, C; Kollias, I; Marchiori, G; Kuntz, J; Way, N; Kuiper, D
1989-06-01
Traditional 2-D cinematography has used a stationary camera with its optical axis perpendicular to the plane of motion. This method has constrained the size of the object plane or has introduced potential errors from a small subject image size with large object field widths. The purpose of this study was to assess a panning technique that could overcome the inherent limitations of small object field widths, small object image sizes and limited movement samples. The proposed technique used a series of reference targets in the object field that provided the necessary scales and origin translations. A 102 m object field was panned. Comparisons between criterion distances and film measured distances for field widths of 46 m and 22 m resulted in absolute mean differences that were comparable to that of the traditional method.
Free-standing supramolecular hydrogel objects by reaction-diffusion
Lovrak, Matija; Hendriksen, Wouter E. J.; Maity, Chandan; Mytnyk, Serhii; van Steijn, Volkert; Eelkema, Rienk; van Esch, Jan H.
2017-01-01
Self-assembly provides access to a variety of molecular materials, yet spatial control over structure formation remains difficult to achieve. Here we show how reaction–diffusion (RD) can be coupled to a molecular self-assembly process to generate macroscopic free-standing objects with control over shape, size, and functionality. In RD, two or more reactants diffuse from different positions to give rise to spatially defined structures on reaction. We demonstrate that RD can be used to locally control formation and self-assembly of hydrazone molecular gelators from their non-assembling precursors, leading to soft, free-standing hydrogel objects with sizes ranging from several hundred micrometres up to centimeters. Different chemical functionalities and gradients can easily be integrated in the hydrogel objects by using different reactants. Our methodology, together with the vast range of organic reactions and self-assembling building blocks, provides a general approach towards the programmed fabrication of soft microscale objects with controlled functionality and shape. PMID:28580948
Takahashi, Chie; Watt, Simon J.
2014-01-01
When we hold an object while looking at it, estimates from visual and haptic cues to size are combined in a statistically optimal fashion, whereby the “weight” given to each signal reflects their relative reliabilities. This allows object properties to be estimated more precisely than would otherwise be possible. Tools such as pliers and tongs systematically perturb the mapping between object size and the hand opening. This could complicate visual-haptic integration because it may alter the reliability of the haptic signal, thereby disrupting the determination of appropriate signal weights. To investigate this we first measured the reliability of haptic size estimates made with virtual pliers-like tools (created using a stereoscopic display and force-feedback robots) with different “gains” between hand opening and object size. Haptic reliability in tool use was straightforwardly determined by a combination of sensitivity to changes in hand opening and the effects of tool geometry. The precise pattern of sensitivity to hand opening, which violated Weber's law, meant that haptic reliability changed with tool gain. We then examined whether the visuo-motor system accounts for these reliability changes. We measured the weight given to visual and haptic stimuli when both were available, again with different tool gains, by measuring the perceived size of stimuli in which visual and haptic sizes were varied independently. The weight given to each sensory cue changed with tool gain in a manner that closely resembled the predictions of optimal sensory integration. The results are consistent with the idea that different tool geometries are modeled by the brain, allowing it to calculate not only the distal properties of objects felt with tools, but also the certainty with which those properties are known. These findings highlight the flexibility of human sensory integration and tool-use, and potentially provide an approach for optimizing the design of visual-haptic devices. PMID:24592245
Manually locating physical and virtual reality objects.
Chen, Karen B; Kimmel, Ryan A; Bartholomew, Aaron; Ponto, Kevin; Gleicher, Michael L; Radwin, Robert G
2014-09-01
In this study, we compared how users locate physical and equivalent three-dimensional images of virtual objects in a cave automatic virtual environment (CAVE) using the hand to examine how human performance (accuracy, time, and approach) is affected by object size, location, and distance. Virtual reality (VR) offers the promise to flexibly simulate arbitrary environments for studying human performance. Previously, VR researchers primarily considered differences between virtual and physical distance estimation rather than reaching for close-up objects. Fourteen participants completed manual targeting tasks that involved reaching for corners on equivalent physical and virtual boxes of three different sizes. Predicted errors were calculated from a geometric model based on user interpupillary distance, eye location, distance from the eyes to the projector screen, and object. Users were 1.64 times less accurate (p < .001) and spent 1.49 times more time (p = .01) targeting virtual versus physical box corners using the hands. Predicted virtual targeting errors were on average 1.53 times (p < .05) greater than the observed errors for farther virtual targets but not significantly different for close-up virtual targets. Target size, location, and distance, in addition to binocular disparity, affected virtual object targeting inaccuracy. Observed virtual box inaccuracy was less than predicted for farther locations, suggesting possible influence of cues other than binocular vision. Human physical interaction with objects in VR for simulation, training, and prototyping involving reaching and manually handling virtual objects in a CAVE are more accurate than predicted when locating farther objects.
The fundamentals of average local variance--Part I: Detecting regular patterns.
Bøcher, Peder Klith; McCloy, Keith R
2006-02-01
The method of average local variance (ALV) computes the mean of the standard deviation values derived for a 3 x 3 moving window on a successively coarsened image to produce a function of ALV versus spatial resolution. In developing ALV, the authors used approximately a doubling of the pixel size at each coarsening of the image. They hypothesized that ALV is low when the pixel size is smaller than the size of scene objects because the pixels on the object will have similar response values. When the pixel and objects are of similar size, they will tend to vary in response and the ALV values will increase. As the size of pixels increase further, more objects will be contained in a single pixel and ALV will decrease. The authors showed that various cover types produced single peak ALV functions that inexplicitly peaked when the pixel size was 1/2 to 3/4 of the object size. This paper reports on work done to explore the characteristics of the various forms of the ALV function and to understand the location of the peaks that occur in this function. The work was conducted using synthetically generated image data. The investigation showed that the hypothesis originally proposed in is not adequate. A new hypothesis is proposed that the ALV function has peak locations that are related to the geometric size of pattern structures in the scene. These structures are not always the same as scene objects. Only in cases where the size of and separation between scene objects are equal does the ALV function detect the size of the objects. In situations where the distance between scene objects are larger than their size, the ALV function has a peak at the object separation, not at the object size. This work has also shown that multiple object structures of different sizes and distances in the image provide multiple peaks in the ALV function and that some of these structures are not implicitly recognized as such from our perspective. However, the magnitude of these peaks depends on the response mix in the structures, complicating their interpretation and analysis. The analysis of the ALV Function is, thus, more complex than that generally reported in the literature.
Bats' avoidance of real and virtual objects: implications for the sonar coding of object size.
Goerlitz, Holger R; Genzel, Daria; Wiegrebe, Lutz
2012-01-01
Fast movement in complex environments requires the controlled evasion of obstacles. Sonar-based obstacle evasion involves analysing the acoustic features of object-echoes (e.g., echo amplitude) that correlate with this object's physical features (e.g., object size). Here, we investigated sonar-based obstacle evasion in bats emerging in groups from their day roost. Using video-recordings, we first show that the bats evaded a small real object (ultrasonic loudspeaker) despite the familiar flight situation. Secondly, we studied the sonar coding of object size by adding a larger virtual object. The virtual object echo was generated by real-time convolution of the bats' calls with the acoustic impulse response of a large spherical disc and played from the loudspeaker. Contrary to the real object, the virtual object did not elicit evasive flight, despite the spectro-temporal similarity of real and virtual object echoes. Yet, their spatial echo features differ: virtual object echoes lack the spread of angles of incidence from which the echoes of large objects arrive at a bat's ears (sonar aperture). We hypothesise that this mismatch of spectro-temporal and spatial echo features caused the lack of virtual object evasion and suggest that the sonar aperture of object echoscapes contributes to the sonar coding of object size. Copyright © 2011 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Yang, T. L.; Dixon, M. W.; Proffitt, D. R.; Kaiser, M. K. (Principal Investigator)
1999-01-01
In six experiments we demonstrate that the vertical-horizontal illusion that is evoked when viewing photographs and line drawings is relatively small, whereas the magnitude of this illusion when large objects are viewed is at least twice as great. Furthermore, we show that the illusion is due more to vertical overestimation than horizontal underestimation. The lack of a difference in vertical overestimation between pictures and line drawings suggests that vertical overestimation in pictures depends solely on the perceived physical size of the projection on the picture surface, rather than on what is apparent about an object's represented size. The vertical-horizontal illusion is influenced by perceived physical size. It is greater when viewing large objects than small pictures of these same objects, even when visual angles are equated.
The visual perception of size and distance.
DOT National Transportation Integrated Search
1962-07-01
The perception of absolute distance has been assumed to be important in the perception of the size of objects and the depth between them. A different hypothesis is proposed. It is asserted that perceived relative size and distance are the primary psy...
Chen, Juan; Sperandio, Irene; Goodale, Melvyn Alan
2015-01-01
Objects rarely appear in isolation in natural scenes. Although many studies have investigated how nearby objects influence perception in cluttered scenes (i.e., crowding), none has studied how nearby objects influence visually guided action. In Experiment 1, we found that participants could scale their grasp to the size of a crowded target even when they could not perceive its size, demonstrating for the first time that neurologically intact participants can use visual information that is not available to conscious report to scale their grasp to real objects in real scenes. In Experiments 2 and 3, we found that changing the eccentricity of the display and the orientation of the flankers had no effect on grasping but strongly affected perception. The differential effects of eccentricity and flanker orientation on perception and grasping show that the known differences in retinotopy between the ventral and dorsal streams are reflected in the way in which people deal with targets in cluttered scenes. © The Author(s) 2014.
Power spectrum weighted edge analysis for straight edge detection in images
NASA Astrophysics Data System (ADS)
Karvir, Hrishikesh V.; Skipper, Julie A.
2007-04-01
Most man-made objects provide characteristic straight line edges and, therefore, edge extraction is a commonly used target detection tool. However, noisy images often yield broken edges that lead to missed detections, and extraneous edges that may contribute to false target detections. We present a sliding-block approach for target detection using weighted power spectral analysis. In general, straight line edges appearing at a given frequency are represented as a peak in the Fourier domain at a radius corresponding to that frequency, and a direction corresponding to the orientation of the edges in the spatial domain. Knowing the edge width and spacing between the edges, a band-pass filter is designed to extract the Fourier peaks corresponding to the target edges and suppress image noise. These peaks are then detected by amplitude thresholding. The frequency band width and the subsequent spatial filter mask size are variable parameters to facilitate detection of target objects of different sizes under known imaging geometries. Many military objects, such as trucks, tanks and missile launchers, produce definite signatures with parallel lines and the algorithm proves to be ideal for detecting such objects. Moreover, shadow-casting objects generally provide sharp edges and are readily detected. The block operation procedure offers advantages of significant reduction in noise influence, improved edge detection, faster processing speed and versatility to detect diverse objects of different sizes in the image. With Scud missile launcher replicas as target objects, the method has been successfully tested on terrain board test images under different backgrounds, illumination and imaging geometries with cameras of differing spatial resolution and bit-depth.
NASA Technical Reports Server (NTRS)
Xu, Kuan-Man
2006-01-01
A new method is proposed to compare statistical differences between summary histograms, which are the histograms summed over a large ensemble of individual histograms. It consists of choosing a distance statistic for measuring the difference between summary histograms and using a bootstrap procedure to calculate the statistical significance level. Bootstrapping is an approach to statistical inference that makes few assumptions about the underlying probability distribution that describes the data. Three distance statistics are compared in this study. They are the Euclidean distance, the Jeffries-Matusita distance and the Kuiper distance. The data used in testing the bootstrap method are satellite measurements of cloud systems called cloud objects. Each cloud object is defined as a contiguous region/patch composed of individual footprints or fields of view. A histogram of measured values over footprints is generated for each parameter of each cloud object and then summary histograms are accumulated over all individual histograms in a given cloud-object size category. The results of statistical hypothesis tests using all three distances as test statistics are generally similar, indicating the validity of the proposed method. The Euclidean distance is determined to be most suitable after comparing the statistical tests of several parameters with distinct probability distributions among three cloud-object size categories. Impacts on the statistical significance levels resulting from differences in the total lengths of satellite footprint data between two size categories are also discussed.
NASA Technical Reports Server (NTRS)
Luo, Yali; Xu, Kuan-Man; Wielicki, Bruce A.; Wong, Takmeng; Eitzen, Zachary A.
2007-01-01
The present study evaluates the ability of a cloud-resolving model (CRM) to simulate the physical properties of tropical deep convective cloud objects identified from a Clouds and the Earth s Radiant Energy System (CERES) data product. The emphasis of this study is the comparisons among the small-, medium- and large-size categories of cloud objects observed during March 1998 and between the large-size categories of cloud objects observed during March 1998 (strong El Ni o) and March 2000 (weak La Ni a). Results from the CRM simulations are analyzed in a way that is consistent with the CERES retrieval algorithm and they are averaged to match the scale of the CERES satellite footprints. Cloud physical properties are analyzed in terms of their summary histograms for each category. It is found that there is a general agreement in the overall shapes of all cloud physical properties between the simulated and observed distributions. Each cloud physical property produced by the CRM also exhibits different degrees of disagreement with observations over different ranges of the property. The simulated cloud tops are generally too high and cloud top temperatures are too low except for the large-size category of March 1998. The probability densities of the simulated top-of-the-atmosphere (TOA) albedos for all four categories are underestimated for high albedos, while those of cloud optical depth are overestimated at its lowest bin. These disagreements are mainly related to uncertainties in the cloud microphysics parameterization and inputs such as cloud ice effective size to the radiation calculation. Summary histograms of cloud optical depth and TOA albedo from the CRM simulations of the large-size category of cloud objects do not differ significantly between the March 1998 and 2000 periods, consistent with the CERES observations. However, the CRM is unable to reproduce the significant differences in the observed cloud top height while it overestimates the differences in the observed outgoing longwave radiation and cloud top temperature between the two periods. Comparisons between the CRM results and the observations for most parameters in March 1998 consistently show that both the simulations and observations have larger differences between the large- and small-size categories than between the large- and medium-size, or between the medium- and small-size categories. However, the simulated cloud properties do not change as much with size as observed. These disagreements are likely related to the spatial averaging of the forcing data and the mismatch in time and in space between the numerical weather prediction model from which the forcing data are produced and the CERES observed cloud systems.
Systems and methods for retaining and removing irradiation targets in a nuclear reactor
Runkle, Gary A.; Matsumoto, Jack T.; Dayal, Yogeshwar; Heinold, Mark R.
2015-12-08
A retainer is placed on a conduit to control movement of objects within the conduit in access-restricted areas. Retainers can prevent or allow movement in the conduit in a discriminatory fashion. A fork with variable-spacing between prongs can be a retainer and be extended or collapsed with respect to the conduit to change the size of the conduit. Different objects of different sizes may thus react to the fork differently, some passing and some being blocked. Retainers can be installed in inaccessible areas and allow selective movement in remote portions of conduit where users cannot directly interface, including below nuclear reactors. Position detectors can monitor the movement of objects through the conduit remotely as well, permitting engagement of a desired level of restriction and object movement. Retainers are useable in a variety of nuclear power plants and with irradiation target delivery, harvesting, driving, and other remote handling or robotic systems.
Linkenauger, Sally A.; Leyrer, Markus; Bülthoff, Heinrich H.; Mohler, Betty J.
2013-01-01
The notion of body-based scaling suggests that our body and its action capabilities are used to scale the spatial layout of the environment. Here we present four studies supporting this perspective by showing that the hand acts as a metric which individuals use to scale the apparent sizes of objects in the environment. However to test this, one must be able to manipulate the size and/or dimensions of the perceiver’s hand which is difficult in the real world due to impliability of hand dimensions. To overcome this limitation, we used virtual reality to manipulate dimensions of participants’ fully-tracked, virtual hands to investigate its influence on the perceived size and shape of virtual objects. In a series of experiments, using several measures, we show that individuals’ estimations of the sizes of virtual objects differ depending on the size of their virtual hand in the direction consistent with the body-based scaling hypothesis. Additionally, we found that these effects were specific to participants’ virtual hands rather than another avatar’s hands or a salient familiar-sized object. While these studies provide support for a body-based approach to the scaling of the spatial layout, they also demonstrate the influence of virtual bodies on perception of virtual environments. PMID:23874681
A mass-density model can account for the size-weight illusion.
Wolf, Christian; Bergmann Tiest, Wouter M; Drewing, Knut
2018-01-01
When judging the heaviness of two objects with equal mass, people perceive the smaller and denser of the two as being heavier. Despite the large number of theories, covering bottom-up and top-down approaches, none of them can fully account for all aspects of this size-weight illusion and thus for human heaviness perception. Here we propose a new maximum-likelihood estimation model which describes the illusion as the weighted average of two heaviness estimates with correlated noise: One estimate derived from the object's mass, and the other from the object's density, with estimates' weights based on their relative reliabilities. While information about mass can directly be perceived, information about density will in some cases first have to be derived from mass and volume. However, according to our model at the crucial perceptual level, heaviness judgments will be biased by the objects' density, not by its size. In two magnitude estimation experiments, we tested model predictions for the visual and the haptic size-weight illusion. Participants lifted objects which varied in mass and density. We additionally varied the reliability of the density estimate by varying the quality of either visual (Experiment 1) or haptic (Experiment 2) volume information. As predicted, with increasing quality of volume information, heaviness judgments were increasingly biased towards the object's density: Objects of the same density were perceived as more similar and big objects were perceived as increasingly lighter than small (denser) objects of the same mass. This perceived difference increased with an increasing difference in density. In an additional two-alternative forced choice heaviness experiment, we replicated that the illusion strength increased with the quality of volume information (Experiment 3). Overall, the results highly corroborate our model, which seems promising as a starting point for a unifying framework for the size-weight illusion and human heaviness perception.
Size Is Big or Little: An Approach to the Dimensionality of Children's Concepts.
ERIC Educational Resources Information Center
Webb, Roger A.
This paper reports a study carried out with 14 children (ranging in age from 2.8 to 3.5 years) which investigated children's concepts of difference. Pairs of small objects differing on a number of dimensions were presented to the children. As each pair of objects was presented, children were asked to select the object that was…
Using Light Curves to Characterize Size and Shape of Pseudo-Debris
NASA Technical Reports Server (NTRS)
Rodriquez, Heather M.; Abercromby, Kira J.; Jarvis, Kandy S.; Barker, Edwin
2006-01-01
Photometric measurements were collected for a new study aimed at estimating orbital debris sizes based on object brightness. To obtain a size from optical measurements the current practice is to assume an albedo and use a normalized magnitude to calculate optical size. However, assuming a single albedo value may not be valid for all objects or orbit types; material type and orientation can mask an object s true optical cross section. This experiment used a CCD camera to record data, a 300 W Xenon, Ozone Free collimated light source to simulate solar illumination, and a robotic arm with five degrees of freedom to move the piece of simulated debris through various orientations. The pseudo-debris pieces used in this experiment originate from the European Space Operations Centre s ESOC2 ground test explosion of a mock satellite. A uniformly illuminated white ping-pong ball was used as a zero-magnitude reference. Each debris piece was then moved through specific orientations and rotations to generate a light curve. This paper discusses the results of five different object-based light curves as measured through an x-rotation. Intensity measurements, from which each light curve was generated, were recorded in five degree increments from zero to 180 degrees. Comparing light curves of different shaped and sized pieces against their characteristic length establishes the start of a database from which an optical size estimation model will be derived in the future.
Sampling artifacts in perspective and stereo displays
NASA Astrophysics Data System (ADS)
Pfautz, Jonathan D.
2001-06-01
The addition of stereo cues to perspective displays is generally expected to improve the perception of depth. However, the display's pixel array samples both perspective and stereo depth cues, introducing inaccuracies and inconsistencies into the representation of an object's depth. The position, size and disparity of an object will be inaccurately presented and size and disparity will be inconsistently presented across depth. These inconsistencies can cause the left and right edges of an object to appear at different stereo depths. This paper describes how these inconsistencies result in conflicts between stereo and perspective depth information. A relative depth judgement task was used to explore these conflicts. Subjects viewed two objects and reported which appeared closer. Three conflicts resulting from inconsistencies caused by sampling were examined: (1) Perspective size and location versus stereo disparity. (2) Perspective size versus perspective location and stereo disparity. (3) Left and right edge disparity versus perspective size and location. In the first two cases, subjects achieved near-perfect accuracy when perspective and disparity cues were complementary. When size and disparity were inconsistent and thus in conflict, stereo dominated perspective. Inconsistency between the disparities of the horizontal edges of an object confused the subjects, even when complementary perspective and stereo information was provided. Since stereo was the dominant cue and was ambiguous across the object, this led to significantly reduced accuracy. Edge inconsistencies also led to more complaints about visual fatigue and discomfort.
Allocentric information is used for memory-guided reaching in depth: A virtual reality study.
Klinghammer, Mathias; Schütz, Immo; Blohm, Gunnar; Fiehler, Katja
2016-12-01
Previous research has demonstrated that humans use allocentric information when reaching to remembered visual targets, but most of the studies are limited to 2D space. Here, we study allocentric coding of memorized reach targets in 3D virtual reality. In particular, we investigated the use of allocentric information for memory-guided reaching in depth and the role of binocular and monocular (object size) depth cues for coding object locations in 3D space. To this end, we presented a scene with objects on a table which were located at different distances from the observer and served as reach targets or allocentric cues. After free visual exploration of this scene and a short delay the scene reappeared, but with one object missing (=reach target). In addition, the remaining objects were shifted horizontally or in depth. When objects were shifted in depth, we also independently manipulated object size by either magnifying or reducing their size. After the scene vanished, participants reached to the remembered target location on the blank table. Reaching endpoints deviated systematically in the direction of object shifts, similar to our previous results from 2D presentations. This deviation was stronger for object shifts in depth than in the horizontal plane and independent of observer-target-distance. Reaching endpoints systematically varied with changes in object size. Our results suggest that allocentric information is used for coding targets for memory-guided reaching in depth. Thereby, retinal disparity and vergence as well as object size provide important binocular and monocular depth cues. Copyright © 2016 Elsevier Ltd. All rights reserved.
NASA Technical Reports Server (NTRS)
Xu, Kuan-Man; Wong, Takmeng; Wielicki, Bruce a.; Parker, Lindsay; Lin, Bing; Eitzen, Zachary A.; Branson, Mark
2006-01-01
Characteristics of tropical deep convective cloud objects observed over the tropical Pacific during January-August 1998 are examined using the Tropical Rainfall Measuring Mission/ Clouds and the Earth s Radiant Energy System single scanner footprint (SSF) data. These characteristics include the frequencies of occurrence and statistical distributions of cloud physical properties. Their variations with cloud-object size, sea surface temperature (SST), and satellite precessing cycle are analyzed in detail. A cloud object is defined as a contiguous patch of the Earth composed of satellite footprints within a single dominant cloud-system type. It is found that statistical distributions of cloud physical properties are significantly different among three size categories of cloud objects with equivalent diameters of 100 - 150 km (small), 150 - 300 km (medium), and > 300 km (large), respectively, except for the distributions of ice particle size. The distributions for the larger-size category of cloud objects are more skewed towards high SSTs, high cloud tops, low cloud-top temperature, large ice water path, high cloud optical depth, low outgoing longwave (LW) radiation, and high albedo than the smaller-size category. As SST varied from one satellite precessing cycle to another, the changes in macrophysical properties of cloud objects over the entire tropical Pacific were small for the large-size category of cloud objects, relative to those of the small- and medium-size categories. This result suggests that the fixed anvil temperature hypothesis of Hartmann and Larson may be valid for the large-size category. Combining with the result that a higher percentage of the large-size category of cloud objects occurs during higher SST subperiods, this implies that macrophysical properties of cloud objects would be less sensitive to further warming of the climate. On the other hand, when cloud objects are classified according to SSTs where large-scale dynamics plays important roles, statistical characteristics of cloud microphysical properties, optical depth and albedo are not sensitive to the SST, but those of cloud macrophysical properties are strongly dependent upon the SST. Frequency distributions of vertical velocity from the European Center for Medium-range Weather Forecasts model that is matched to each cloud object are used to interpret some of the findings in this study.
Blood drop size in passive dripping from weapons.
Kabaliuk, N; Jermy, M C; Morison, K; Stotesbury, T; Taylor, M C; Williams, E
2013-05-10
Passive dripping, the slow dripping of blood under gravity, is responsible for some bloodstains found at crime scenes, particularly drip trails left by a person moving through the scene. Previous work by other authors has established relationships, under ideal conditions, between the size of the stain, the number of spines and satellite stains, the roughness of the surface, the size of the blood droplet and the height from which it falls. To apply these relationships to infer the height of fall requires independent knowledge of the size of the droplet. This work aims to measure the size of droplets falling from objects representative of hand-held weapons. Pig blood was used, with density, surface tension and viscosity controlled to fall within the normal range for human blood. Distilled water was also tested as a reference. Drips were formed from stainless steel objects with different roughnesses including cylinders of diameter between 10 and 100 mm, and flat plates. Small radius objects including a knife and a wrench were also tested. High speed images of the falling drops were captured. The primary blood drop size ranged from 4.15±0.11 mm up to 6.15±0.15 mm (depending on the object), with the smaller values from sharper objects. The primary drop size correlated only weakly with surface roughness, over the roughness range studied. The number of accompanying droplets increased with the object size, but no significant correlation with surface texture was observed. Dripping of blood produced slightly smaller drops, with more accompanying droplets, than dripping water. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.
Martian planetwide crater distributions - Implications for geologic history and surface processes
NASA Technical Reports Server (NTRS)
Soderblom, L. A.; Condit, C. D.; West, R. A.; Herman, B. M.; Kreidler, T. J.
1974-01-01
Three different diameter size ranges are considered in connection with the Martian crater distribution, taking into account small craters from 0.6 to 1.2 km, intermediate-sized craters from 4 to 10 km, and large craters with diameters exceeding 20 km. One of the objectives of the investigation reported is to establish the effects of eolian processes in the modification of craters in the different size ranges. Another objective is concerned with a description of the genetic relationships among the three size ranges of craters. Observables related to the relative age of geologic provinces are to be separated from observables related to geographic variations in eolian transport and deposition. Lunar and Martian cratering histories are compared as a basis for establishing relative and absolute time scales for the geological evolution of Mars.
Stress Wave E-Rating of Structural Timber—Size and Moisture Content Effects
Xiping Wang
2013-01-01
The objectives of this study were to investigate the influence of cross sectional size and moisture content on stress wave properties of structural timber in various sizes and evaluate the feasibility of using stress wave method to E-rate timber in green conditions. Four different sizes of Douglas-fir (Pseudotsuga menziesii) square timbers were...
Ensemble coding remains accurate under object and spatial visual working memory load.
Epstein, Michael L; Emmanouil, Tatiana A
2017-10-01
A number of studies have provided evidence that the visual system statistically summarizes large amounts of information that would exceed the limitations of attention and working memory (ensemble coding). However the necessity of working memory resources for ensemble coding has not yet been tested directly. In the current study, we used a dual task design to test the effect of object and spatial visual working memory load on size averaging accuracy. In Experiment 1, we tested participants' accuracy in comparing the mean size of two sets under various levels of object visual working memory load. Although the accuracy of average size judgments depended on the difference in mean size between the two sets, we found no effect of working memory load. In Experiment 2, we tested the same average size judgment while participants were under spatial visual working memory load, again finding no effect of load on averaging accuracy. Overall our results reveal that ensemble coding can proceed unimpeded and highly accurately under both object and spatial visual working memory load, providing further evidence that ensemble coding reflects a basic perceptual process distinct from that of individual object processing.
3-Dimensional Scene Perception during Active Electrolocation in a Weakly Electric Pulse Fish
von der Emde, Gerhard; Behr, Katharina; Bouton, Béatrice; Engelmann, Jacob; Fetz, Steffen; Folde, Caroline
2010-01-01
Weakly electric fish use active electrolocation for object detection and orientation in their environment even in complete darkness. The African mormyrid Gnathonemus petersii can detect object parameters, such as material, size, shape, and distance. Here, we tested whether individuals of this species can learn to identify 3-dimensional objects independently of the training conditions and independently of the object's position in space (rotation-invariance; size-constancy). Individual G. petersii were trained in a two-alternative forced-choice procedure to electrically discriminate between a 3-dimensional object (S+) and several alternative objects (S−). Fish were then tested whether they could identify the S+ among novel objects and whether single components of S+ were sufficient for recognition. Size-constancy was investigated by presenting the S+ together with a larger version at different distances. Rotation-invariance was tested by rotating S+ and/or S− in 3D. Our results show that electrolocating G. petersii could (1) recognize an object independently of the S− used during training. When only single components of a complex S+ were offered, recognition of S+ was more or less affected depending on which part was used. (2) Object-size was detected independently of object distance, i.e. fish showed size-constancy. (3) The majority of the fishes tested recognized their S+ even if it was rotated in space, i.e. these fishes showed rotation-invariance. (4) Object recognition was restricted to the near field around the fish and failed when objects were moved more than about 4 cm away from the animals. Our results indicate that even in complete darkness our G. petersii were capable of complex 3-dimensional scene perception using active electrolocation. PMID:20577635
Digital holographic image fusion for a larger size object using compressive sensing
NASA Astrophysics Data System (ADS)
Tian, Qiuhong; Yan, Liping; Chen, Benyong; Yao, Jiabao; Zhang, Shihua
2017-05-01
Digital holographic imaging fusion for a larger size object using compressive sensing is proposed. In this method, the high frequency component of the digital hologram under discrete wavelet transform is represented sparsely by using compressive sensing so that the data redundancy of digital holographic recording can be resolved validly, the low frequency component is retained totally to ensure the image quality, and multiple reconstructed images with different clear parts corresponding to a laser spot size are fused to realize the high quality reconstructed image of a larger size object. In addition, a filter combing high-pass and low-pass filters is designed to remove the zero-order term from a digital hologram effectively. The digital holographic experimental setup based on off-axis Fresnel digital holography was constructed. The feasible and comparative experiments were carried out. The fused image was evaluated by using the Tamura texture features. The experimental results demonstrated that the proposed method can improve the processing efficiency and visual characteristics of the fused image and enlarge the size of the measured object effectively.
Image-size differences worsen stereopsis independent of eye position
Vlaskamp, Björn N. S.; Filippini, Heather R.; Banks, Martin S.
2010-01-01
With the eyes in forward gaze, stereo performance worsens when one eye’s image is larger than the other’s. Near, eccentric objects naturally create retinal images of different sizes. Does this mean that stereopsis exhibits deficits for such stimuli? Or does the visual system compensate for the predictable image-size differences? To answer this, we measured discrimination of a disparity-defined shape for different relative image sizes. We did so for different gaze directions, some compatible with the image-size difference and some not. Magnifications of 10–15% caused a clear worsening of stereo performance. The worsening was determined only by relative image size and not by eye position. This shows that no neural compensation for image-size differences accompanies eye-position changes, at least prior to disparity estimation. We also found that a local cross-correlation model for disparity estimation performs like humans in the same task, suggesting that the decrease in stereo performance due to image-size differences is a byproduct of the disparity-estimation method. Finally, we looked for compensation in an observer who has constantly different image sizes due to differing eye lengths. She performed best when the presented images were roughly the same size, indicating that she has compensated for the persistent image-size difference. PMID:19271927
Truppa, Valentina; Carducci, Paola; Trapanese, Cinzia; Hanus, Daniel
2015-01-01
Most experimental paradigms to study visual cognition in humans and non-human species are based on discrimination tasks involving the choice between two or more visual stimuli. To this end, different types of stimuli and procedures for stimuli presentation are used, which highlights the necessity to compare data obtained with different methods. The present study assessed whether, and to what extent, capuchin monkeys’ ability to solve a size discrimination problem is influenced by the type of procedure used to present the problem. Capuchins’ ability to generalise knowledge across different tasks was also evaluated. We trained eight adult tufted capuchin monkeys to select the larger of two stimuli of the same shape and different sizes by using pairs of food items (Experiment 1), computer images (Experiment 1) and objects (Experiment 2). Our results indicated that monkeys achieved the learning criterion faster with food stimuli compared to both images and objects. They also required consistently fewer trials with objects than with images. Moreover, female capuchins had higher levels of acquisition accuracy with food stimuli than with images. Finally, capuchins did not immediately transfer the solution of the problem acquired in one task condition to the other conditions. Overall, these findings suggest that – even in relatively simple visual discrimination problems where a single perceptual dimension (i.e., size) has to be judged – learning speed strongly depends on the mode of presentation. PMID:25927363
Vibrissal touch sensing in the harbor seal (Phoca vitulina): how do seals judge size?
Grant, Robyn; Wieskotten, Sven; Wengst, Nina; Prescott, Tony; Dehnhardt, Guido
2013-06-01
"Whisker specialists" such as rats, shrews, and seals actively employ their whiskers to explore their environments and extract object properties such as size, shape, and texture. It has been suggested that whiskers could be used to discriminate between different sized objects in one of two ways: (i) to use whisker positions, such as angular position, spread or amplitude to approximate size; or (ii) to calculate the number of whiskers that contact an object. This study describes in detail how two adult harbor seals use their whiskers to differentiate between three sizes of disk. The seals judged size very fast, taking <400 ms. In addition, they oriented their smaller, most rostral, ventral whiskers to the disks, so that more whiskers contacted the surface, complying to a maximal contact sensing strategy. Data from this study supports the suggestion that it is the number of whisker contacts that predict disk size, rather than how the whiskers are positioned (angular position), the degree to which they are moved (amplitude) or how spread out they are (angular spread).
On the validity and robustness of the scale error phenomenon in early childhood.
DeLoache, Judy S; LoBue, Vanessa; Vanderborght, Mieke; Chiong, Cynthia
2013-02-01
Scale errors is a term referring to very young children's serious efforts to perform actions on miniature replica objects that are impossible due to great differences in the size of the child's body and the size of the target objects. We report three studies providing further documentation of scale errors and investigating the validity and robustness of the phenomenon. In the first, we establish that 2-year-olds' behavior in response to prompts to "pretend" with miniature replica objects differs dramatically from scale errors. The second and third studies address the robustness of the phenomenon and its relative imperviousness to attempts to influence the rate of scale errors. Copyright © 2012 Elsevier Inc. All rights reserved.
Gravitational acceleration as a cue for absolute size and distance?
NASA Technical Reports Server (NTRS)
Hecht, H.; Kaiser, M. K.; Banks, M. S.
1996-01-01
When an object's motion is influenced by gravity, as in the rise and fall of a thrown ball, the vertical component of acceleration is roughly constant at 9.8 m/sec2. In principle, an observer could use this information to estimate the absolute size and distance of the object (Saxberg, 1987a; Watson, Banks, von Hofsten, & Royden, 1992). In five experiments, we examined people's ability to utilize the size and distance information provided by gravitational acceleration. Observers viewed computer simulations of an object rising and falling on a trajectory aligned with the gravitational vector. The simulated objects were balls of different diameters presented across a wide range of simulated distances. Observers were asked to identify the ball that was presented and to estimate its distance. The results showed that observers were much more sensitive to average velocity than to the gravitational acceleration pattern. Likewise, verticality of the motion and visibility of the trajectory's apex had negligible effects on the accuracy of size and distance judgments.
Heinrich, Andreas; Teichgräber, Ulf K; Güttler, Felix V
2015-12-01
The standard ASTM F2119 describes a test method for measuring the size of a susceptibility artifact based on the example of a passive implant. A pixel in an image is considered to be a part of an image artifact if the intensity is changed by at least 30% in the presence of a test object, compared to a reference image in which the test object is absent (reference value). The aim of this paper is to simplify and accelerate the test method using a histogram-based reference value. Four test objects were scanned parallel and perpendicular to the main magnetic field, and the largest susceptibility artifacts were measured using two methods of reference value determination (reference image-based and histogram-based reference value). The results between both methods were compared using the Mann-Whitney U-test. The difference between both reference values was 42.35 ± 23.66. The difference of artifact size was 0.64 ± 0.69 mm. The artifact sizes of both methods did not show significant differences; the p-value of the Mann-Whitney U-test was between 0.710 and 0.521. A standard-conform method for a rapid, objective, and reproducible evaluation of susceptibility artifacts could be implemented. The result of the histogram-based method does not significantly differ from the ASTM-conform method.
NASA Astrophysics Data System (ADS)
Ghasemy Yaghin, R.; Fatemi Ghomi, S. M. T.; Torabi, S. A.
2015-10-01
In most markets, price differentiation mechanisms enable manufacturers to offer different prices for their products or services in different customer segments; however, the perfect price discrimination is usually impossible for manufacturers. The importance of accounting for uncertainty in such environments spurs an interest to develop appropriate decision-making tools to deal with uncertain and ill-defined parameters in joint pricing and lot-sizing problems. This paper proposes a hybrid bi-objective credibility-based fuzzy optimisation model including both quantitative and qualitative objectives to cope with these issues. Taking marketing and lot-sizing decisions into account simultaneously, the model aims to maximise the total profit of manufacturer and to improve service aspects of retailing simultaneously to set different prices with arbitrage consideration. After applying appropriate strategies to defuzzify the original model, the resulting non-linear multi-objective crisp model is then solved by a fuzzy goal programming method. An efficient stochastic search procedure using particle swarm optimisation is also proposed to solve the non-linear crisp model.
Tofts, P S; Silver, N C; Barker, G J; Gass, A
2005-07-01
There are currently four problems in characterising small nonuniform lesions or other objects in Magnetic Resonance images where partial volume effects are significant. Object size is over- or under-estimated; boundaries are often not reproducible; mean object value cannot be measured; and fuzzy borders cannot be accommodated. A new measure, Object Strength, is proposed. This is the sum of all abnormal intensities, above a uniform background value. For a uniform object, this is simply the product of the increase in intensity and the size of the object. Biologically, this could be at least as relevant as existing measures of size or mean intensity. We hypothesise that Object Strength will perform better than traditional area measurements in characterising small objects. In a pilot study, the reproducibility of object strength measurements was investigated using MR images of small multiple sclerosis (MS) lesions. In addition, accuracy was investigated using artificial lesions of known volume (0.3-6.2 ml) and realistic appearance. Reproducibility approached that of area measurements (in 33/90 lesion reports the difference between repeats was less than for area measurements). Total lesion volume was accurate to 0.2%. In conclusion, Object Strength has potential for improved characterisation of small lesions and objects in imaging and possibly spectroscopy.
Laméris, Joran; Hipp, John R; Tolsma, Jochem
2018-05-01
This study examines the effects of neighborhood racial in-group size, economic deprivation and the prevalence of crime on neighborhood cohesion among U.S. whites. We explore to what extent residents' perceptions of their neighborhood mediate these macro-micro relationships. We use a recent individual-level data set, the American Social Fabric Study (2012/2013), enriched with contextual-level data from the U.S. Census Bureau (2010) and employ multi-level structural equation models. We show that the racial in-group size is positively related to neighborhood cohesion and that neighborhood cohesion is lower in communities with a high crime rate. Individuals' perceptions of the racial in-group size partly mediate the relationship between the objective racial in-group size and neighborhood cohesion. Residents' perceptions of unsafety from crime also appear to be a mediating factor, not only for the objective crime rate but also for the objective racial in-group size. This is in line with our idea that racial stereotypes link racial minorities to crime whereby neighborhoods with a large non-white population are perceived to be more unsafe. Residents of the same neighborhood differ in how they perceive the degree of economic decay of the neighborhood and this causes them to evaluate neighborhood cohesion differently, however perceptions of neighborhood economic decay do not explain the link between the objective neighborhood context and neighborhood cohesion. Copyright © 2018. Published by Elsevier Inc.
ERIC Educational Resources Information Center
Devins, David; Johnson, Steve; Sutherland, John
2004-01-01
This paper examines a data set that has its origins in European Social Fund Objective 4 financed training programmes in small- to medium-sized enterprises (SMEs) in Britain to examine the extent to which three different personal development outcomes are attributable to different types of skills acquired during the training process. The three…
Visual search for arbitrary objects in real scenes.
Wolfe, Jeremy M; Alvarez, George A; Rosenholtz, Ruth; Kuzmova, Yoana I; Sherman, Ashley M
2011-08-01
How efficient is visual search in real scenes? In searches for targets among arrays of randomly placed distractors, efficiency is often indexed by the slope of the reaction time (RT) × Set Size function. However, it may be impossible to define set size for real scenes. As an approximation, we hand-labeled 100 indoor scenes and used the number of labeled regions as a surrogate for set size. In Experiment 1, observers searched for named objects (a chair, bowl, etc.). With set size defined as the number of labeled regions, search was very efficient (~5 ms/item). When we controlled for a possible guessing strategy in Experiment 2, slopes increased somewhat (~15 ms/item), but they were much shallower than search for a random object among other distinctive objects outside of a scene setting (Exp. 3: ~40 ms/item). In Experiments 4-6, observers searched repeatedly through the same scene for different objects. Increased familiarity with scenes had modest effects on RTs, while repetition of target items had large effects (>500 ms). We propose that visual search in scenes is efficient because scene-specific forms of attentional guidance can eliminate most regions from the "functional set size" of items that could possibly be the target.
Action-specific effects in aviation: what determines judged runway size?
Gray, Rob; Navia, José Antonio; Allsop, Jonathan
2014-01-01
Several recent studies have shown that the performance of a skill that involves acting on a goal object can influence one's judgment of the size of that object. The present study investigated this effect in an aviation context. Novice pilots were asked to perform a series of visual approach and landing manoeuvres in a flight simulator. After each landing, participants next performed a task in which runway size was judged for different simulated altitudes. Gaze behaviour and control stick kinematics were also analyzed. There were significant relationships between judged runway size and multiple action-related variables including touchdown velocity, time fixating the runway, and the magnitude and frequency of control inputs. These findings suggest that relationship between the perception of a target object and action is not solely determined by performance success or failure but rather involves a relationship between multiple variables that reflect the actor's ability.
Role of a texture gradient in the perception of relative size.
Tozawa, Junko
2010-01-01
Two theories regarding the role of a texture gradient in the perception of the relative size of objects are compared. Relational theory states that relative size is directly specified by the projective ratio of the numbers of texture elements spanned by objects. Distance calibration theory assumes that relative size is a product of visual angle and distance, once the distance is specified by the texture. Experiment 1 involved three variables: background (no texture, texture gradient patterns), the ratio of heights of the comparison stimulus to a standard (three levels), and angular vertical separation of the standard stimulus below the horizon (two levels). The effect of the retinal length of the comparison stimulus was examined in experiment 2. In both experiments, participants judged both the apparent size and distance of a comparison stimulus relative to a standard stimulus. Results suggest that the cues selected by observers to judge relative size were to some degree different from those used to judge relative distance. Relative size was strongly affected by a texture gradient and the retinal length of a comparison stimulus whereas relative distance perception was affected by relative height. When dominant cues that specify size are different from those which specify distance, relational theory might provide a better account of relative size perception than distance calibration theory.
Tactile sensitivity of gloved hands in the cold operation.
Geng, Q; Kuklane, K; Holmér, I
1997-11-01
In this study, tactile sensitivity of gloved hand in the cold operation has been investigated. The relations among physical properties of protective gloves and hand tactile sensitivity and cold protection were also analysed both objectively and subjectively. Subjects with various gloves participated in the experimental study during cold exposure at different ambient temperatures of -12 degrees C and -25 degrees C. Tactual performance was measured using an identification task with various sizes of objects over the percentage of misjudgment. Forearm, hand and finger skin temperatures were also recorded throughout. The experimental data were analysed using analysis of variance (ANOVA) model and the Tukey's multiple range test. The results obtained indicated that the tactual performance was affected both by gloves and by hands/fingers cooling. Effect of object size on the tactile discrimination was significant and the misjudgment increased when similar sizes of objects were identified, especially at -25 degrees C.
A phantom for quantitation of partial volume effects in ECT
DOE Office of Scientific and Technical Information (OSTI.GOV)
Mullani, N.A.
1989-02-01
A special phantom has been designed, built and tested to measure the quantitative recovery of ECT data from the heart as a function of the size of the object and the angulation of a 1 cm thick simulated myocardium inclined with respect to the image plane. The phantom consists of five objects of 0.5, 1.0, 1.5. 2.0, and 3.0 cm width and six 1 cm thick strips inclined at 0, 30, 45, 60, 90, and -90 degrees with respect to the axial direction. Recovery coefficients for different object sizes and simulated 1 cm thick myocardium inclined at different angles canmore » be obtained from a single scan. Adequacy of axial sampling can be observed visually by creating the long axis view of the phantom.« less
ERIC Educational Resources Information Center
Plumert, Jodie M.; Nichols-Whitehead, Penney
2007-01-01
We conducted four experiments to examine developmental differences in preferences for using color, size, and location information to disambiguate hiding places. Three- and 4-year-olds and adults described how to find a miniature mouse that was hidden in one of two highly similar small objects in a dollhouse. In Experiment 1, the hiding places…
Selected properties of particleboard panels manufactured from rice straws of different geometries
Xianjun Li; Zhiyong Cai; Jerrold E. Winandy; Altaf H. Basta
2010-01-01
The objective is to evaluate the primary mechanical and physical properties of particleboard made from hammer-milled rice straw particles of six different categories and two types of resins. The results show the performance of straw particleboards is highly dependent upon the straw particle size controlled by the opening size of the perforated plate inside the hammer-...
Sizing Up Objects: The Effect of Diminutive Forms on Positive Mood, Value, and Size Judgments
Parzuchowski, Michał; Bocian, Konrad; Gygax, Pascal
2016-01-01
Language (e.g., structure, morphology, and wording) can direct our attention toward the specific properties of an object, in turn influencing the mental representation of that same object. In this paper, we examined this idea by focusing on a particular linguistic form of diminution used in many languages (e.g., in Polish, Spanish, and Portuguese) to refer to an object as being “smaller.” Interestingly, although objects are usually considered “better” when they are bigger in size, objects described with linguistic diminution can also refer to those that are emotionally positive. Across three experiments conducted in Polish, we examined this lexical ambiguity in terms of mood (Experiment 1), subjective quality and monetary value (Experiment 2), and choice selection (Experiment 3). Overall, we found that people evaluate objects differently depending on the linguistic form (i.e., with or without diminution) with which they are described, and that it was related to the perceptual representation of these objects, and not their affective status. Objects described with diminution are evaluated as less satisfying and of lesser value and this effect is attributed to the way participants represent the objects (i.e., encoded and memorized). The generalizability of these effects is discussed. PMID:27721802
Efficiencies for the statistics of size discrimination.
Solomon, Joshua A; Morgan, Michael; Chubb, Charles
2011-10-19
Different laboratories have achieved a consensus regarding how well human observers can estimate the average orientation in a set of N objects. Such estimates are not only limited by visual noise, which perturbs the visual signal of each object's orientation, they are also inefficient: Observers effectively use only √N objects in their estimates (e.g., S. C. Dakin, 2001; J. A. Solomon, 2010). More controversial is the efficiency with which observers can estimate the average size in an array of circles (e.g., D. Ariely, 2001, 2008; S. C. Chong, S. J. Joo, T.-A. Emmanouil, & A. Treisman, 2008; K. Myczek & D. J. Simons, 2008). Of course, there are some important differences between orientation and size; nonetheless, it seemed sensible to compare the two types of estimate against the same ideal observer. Indeed, quantitative evaluation of statistical efficiency requires this sort of comparison (R. A. Fisher, 1925). Our first step was to measure the noise that limits size estimates when only two circles are compared. Our results (Weber fractions between 0.07 and 0.14 were necessary for 84% correct 2AFC performance) are consistent with the visual system adding the same amount of Gaussian noise to all logarithmically transduced circle diameters. We exaggerated this visual noise by randomly varying the diameters in (uncrowded) arrays of 1, 2, 4, and 8 circles and measured its effect on discrimination between mean sizes. Efficiencies inferred from all four observers significantly exceed 25% and, in two cases, approach 100%. More consistent are our measurements of just-noticeable differences in size variance. These latter results suggest between 62 and 75% efficiency for variance discriminations. Although our observers were no more efficient comparing size variances than they were at comparing mean sizes, they were significantly more precise. In other words, our results contain evidence for a non-negligible source of late noise that limits mean discriminations but not variance discriminations.
The effect of a finite focal spot size on location dependent detectability in a fan beam CT system
NASA Astrophysics Data System (ADS)
Kim, Byeongjoon; Baek, Jongduk
2017-03-01
A finite focal spot size is one of the sources to degrade the resolution performance in a fan beam CT system. In this work, we investigated the effect of the finite focal spot size on signal detectability. For the evaluation, five spherical objects with diameters of 1 mm, 2 mm, 3 mm, 4 mm, and 5 mm were used. The optical focal spot size viewed at the iso-center was a 1 mm (height) × 1 mm (width) with a target angle of 7 degrees, corresponding to an 8.21 mm (i.e., 1 mm / sin (7°)) focal spot length. Simulated projection data were acquired using 8 × 8 source lets, and reconstructed by Hanning weighted filtered backprojection. For each spherical object, the detectability was calculated at (0 mm, 0 mm) and (0 mm, 200 mm) using two image quality metrics: pixel signal to noise ratio (SNR) and detection SNR. For all signal sizes, the pixel SNR is higher at the iso-center since the noise variance at the off-center is much higher than that at the iso-center due to the backprojection weightings used in direct fan beam reconstruction. In contrast, detection SNR shows similar values for different spherical objects except 1 mm and 2 mm diameter spherical objects. Overall, the results indicate the resolution loss caused by the finite focal spot size degrades the detection performance, especially for small objects with less than 2 mm diameter.
The surface-to-volume ratio in thermal physics: from cheese cube physics to animal metabolism
NASA Astrophysics Data System (ADS)
Planinšič, Gorazd; Vollmer, Michael
2008-03-01
The surface-to-volume ratio is an important quantity in thermal physics. For example it governs the behaviour of heating or cooling of physical objects as a function of size like, e.g. cubes or spheres made of different material. The starting point in our paper is the simple physics problem of how cheese cubes of different sizes behave if heated either in a conventional oven or in a microwave oven. The outcome of these experiments depends on a balance between heating and cooling with the surface-to-volume ratio (S/V) as the key parameter. The role of (S/V) becomes most obvious in studying cooling curves of differently sized objects like cubes or spheres, alone. Besides problems in thermal physics, the surface-to-volume ratio has many important applications in biochemistry, chemistry and biology. It allows us to draw general conclusions concerning the thermal and mechanical properties of different-sized animals, in particular their metabolism. Hence, this topic offers rich contexts for interdisciplinary teaching. An example presented in this paper starts in physics while studying thermal properties of cheese cubes and ends up in biology by discussing the differences in food intake of animals from small mice to huge elephants.
Generalized index for spatial data sets as a measure of complete spatial randomness
NASA Astrophysics Data System (ADS)
Hackett-Jones, Emily J.; Davies, Kale J.; Binder, Benjamin J.; Landman, Kerry A.
2012-06-01
Spatial data sets, generated from a wide range of physical systems can be analyzed by counting the number of objects in a set of bins. Previous work has been limited to equal-sized bins, which are inappropriate for some domains (e.g., circular). We consider a nonequal size bin configuration whereby overlapping or nonoverlapping bins cover the domain. A generalized index, defined in terms of a variance between bin counts, is developed to indicate whether or not a spatial data set, generated from exclusion or nonexclusion processes, is at the complete spatial randomness (CSR) state. Limiting values of the index are determined. Using examples, we investigate trends in the generalized index as a function of density and compare the results with those using equal size bins. The smallest bin size must be much larger than the mean size of the objects. We can determine whether a spatial data set is at the CSR state or not by comparing the values of a generalized index for different bin configurations—the values will be approximately the same if the data is at the CSR state, while the values will differ if the data set is not at the CSR state. In general, the generalized index is lower than the limiting value of the index, since objects do not have access to the entire region due to blocking by other objects. These methods are applied to two applications: (i) spatial data sets generated from a cellular automata model of cell aggregation in the enteric nervous system and (ii) a known plant data distribution.
NASA Technical Reports Server (NTRS)
Reid, Christopher; Harvill, Lauren; England, Scott; Young, Karen; Norcross, Jason; Rajulu, Sudhakar
2014-01-01
The objective of this project was to assess the performance differences between a nominally sized Extravehicular Mobility Unit (EMU) space suit and a nominal +1 (plus) sized EMU. Method: This study evaluated suit size conditions by using metabolic cost, arm mobility, and arm strength as performance metrics. Results: Differences between the suit sizes were found only in shoulder extension strength being 15.8% greater for the plus size. Discussion: While this study was able to identify motions and activities that were considered to be practically or statistically different, it does not signify that use of a plus sized suit should be prohibited. Further testing would be required that either pertained to a particular mission critical task or better simulates a microgravity environment that the EMU suit was designed to work in.
MR image analytics to characterize upper airway architecture in children with OSAS
NASA Astrophysics Data System (ADS)
Tong, Yubing; Udupa, Jayaram K.; Torigian, Drew A.; Matsumoto, Monica M. S.; Sin, Sanghun; Arens, Raanan
2015-03-01
Mechanisms leading to Obstructive Sleep Apnea Syndrome (OSAS) in obese children are not well understood. We previously analyzed polysomnographic and demographic data to study the anatomical characteristics of the upper airway and body composition in two groups of obese children with and without OSAS, where object volume was evaluated. In this paper, in order to better understand the disease we expand the analysis considering a variety of features that include object-specific features such as size, surface area, sphericity, and image intensity properties of fourteen objects in the vicinity of the upper airway, as well as inter-object relationships such as distance between objects. Our preliminary results indicate several interesting phenomena: volumes and surface areas of adenoid and tonsils increase statistically significantly in OSAS. Standardized T2-weighted MR image intensities differ statistically significantly between the two groups, implying that perhaps intrinsic tissue composition undergoes changes in OSAS. Inter-object distances are significantly different between the two groups for object pairs (skin, oropharynx), (skin, fat pad), (skin, soft palate), (mandible, tongue), (oropharynx, soft palate), (left tonsil, oropharynx), (left tonsil, fat pad) and (left tonsil, right tonsil). We conclude that treatment methods for OSAS such as adenotonsillectomy should respect proportional object size relationships and spatial arrangement of objects as they exist in control subjects.
Spectral saliency via automatic adaptive amplitude spectrum analysis
NASA Astrophysics Data System (ADS)
Wang, Xiaodong; Dai, Jialun; Zhu, Yafei; Zheng, Haiyong; Qiao, Xiaoyan
2016-03-01
Suppressing nonsalient patterns by smoothing the amplitude spectrum at an appropriate scale has been shown to effectively detect the visual saliency in the frequency domain. Different filter scales are required for different types of salient objects. We observe that the optimal scale for smoothing amplitude spectrum shares a specific relation with the size of the salient region. Based on this observation and the bottom-up saliency detection characterized by spectrum scale-space analysis for natural images, we propose to detect visual saliency, especially with salient objects of different sizes and locations via automatic adaptive amplitude spectrum analysis. We not only provide a new criterion for automatic optimal scale selection but also reserve the saliency maps corresponding to different salient objects with meaningful saliency information by adaptive weighted combination. The performance of quantitative and qualitative comparisons is evaluated by three different kinds of metrics on the four most widely used datasets and one up-to-date large-scale dataset. The experimental results validate that our method outperforms the existing state-of-the-art saliency models for predicting human eye fixations in terms of accuracy and robustness.
Size and moisture distribution characteristics of walnuts and their components
USDA-ARS?s Scientific Manuscript database
The objective of this study was to determine the size characteristics and moisture content (MC) distributions of individual walnuts and their components, including hulls, shells and kernels under different harvest conditions. Measurements were carried out for three walnut varieties, Tulare, Howard a...
Lower pitch is larger, yet falling pitches shrink.
Eitan, Zohar; Schupak, Asi; Gotler, Alex; Marks, Lawrence E
2014-01-01
Experiments using diverse paradigms, including speeded discrimination, indicate that pitch and visually-perceived size interact perceptually, and that higher pitch is congruent with smaller size. While nearly all of these studies used static stimuli, here we examine the interaction of dynamic pitch and dynamic size, using Garner's speeded discrimination paradigm. Experiment 1 examined the interaction of continuous rise/fall in pitch and increase/decrease in object size. Experiment 2 examined the interaction of static pitch and size (steady high/low pitches and large/small visual objects), using an identical procedure. Results indicate that static and dynamic auditory and visual stimuli interact in opposite ways. While for static stimuli (Experiment 2), higher pitch is congruent with smaller size (as suggested by earlier work), for dynamic stimuli (Experiment 1), ascending pitch is congruent with growing size, and descending pitch with shrinking size. In addition, while static stimuli (Experiment 2) exhibit both congruence and Garner effects, dynamic stimuli (Experiment 1) present congruence effects without Garner interference, a pattern that is not consistent with prevalent interpretations of Garner's paradigm. Our interpretation of these results focuses on effects of within-trial changes on processing in dynamic tasks and on the association of changes in apparent size with implied changes in distance. Results suggest that static and dynamic stimuli can differ substantially in their cross-modal mappings, and may rely on different processing mechanisms.
Small-size pedestrian detection in large scene based on fast R-CNN
NASA Astrophysics Data System (ADS)
Wang, Shengke; Yang, Na; Duan, Lianghua; Liu, Lu; Dong, Junyu
2018-04-01
Pedestrian detection is a canonical sub-problem of object detection with high demand during recent years. Although recent deep learning object detectors such as Fast/Faster R-CNN have shown excellent performance for general object detection, they have limited success for small size pedestrian detection in large-view scene. We study that the insufficient resolution of feature maps lead to the unsatisfactory accuracy when handling small instances. In this paper, we investigate issues involving Fast R-CNN for pedestrian detection. Driven by the observations, we propose a very simple but effective baseline for pedestrian detection based on Fast R-CNN, employing the DPM detector to generate proposals for accuracy, and training a fast R-CNN style network to jointly optimize small size pedestrian detection with skip connection concatenating feature from different layers to solving coarseness of feature maps. And the accuracy is improved in our research for small size pedestrian detection in the real large scene.
Petzoldt, Tibor
2016-10-01
Crashes at railway level crossings are a key problem for railway operations. It has been suggested that a potential explanation for such crashes might lie in a so-called size speed bias, which describes the phenomenon that observers underestimate the speed of larger objects, such as aircraft or trains. While there is some evidence that this size speed bias indeed exists, it is somewhat at odds with another well researched phenomenon, the size arrival effect. When asked to judge the time it takes an approaching object to arrive at a predefined position (time to arrival, TTA), observers tend to provide lower estimates for larger objects. In that case, road users' crossing decisions when confronted with larger vehicles should be rather conservative, which has been confirmed in multiple studies on gap acceptance. The aim of the experiment reported in this paper was to clarify the relationship between size speed bias and size arrival effect. Employing a relative judgment task, both speed and TTA estimates were assessed for virtual depictions of a train and a truck, using a car as a reference to compare against. The results confirmed the size speed bias for the speed judgments, with both train and truck being perceived as travelling slower than the car. A comparable bias was also present in the TTA estimates for the truck. In contrast, no size arrival effect could be found for the train or the truck, neither in the speed nor the TTA judgments. This finding is inconsistent with the fact that crossing behaviour when confronted with larger vehicles appears to be consistently more conservative. This discrepancy might be interpreted as an indication that factors other than perceived speed or TTA play an important role for the differences in gap acceptance between different types of vehicles. Copyright © 2016 Elsevier Ltd. All rights reserved.
Small or far away? Size and distance perception in the praying mantis
Bissianna, Geoffrey
2016-01-01
Stereo or ‘3D’ vision is an important but costly process seen in several evolutionarily distinct lineages including primates, birds and insects. Many selective advantages could have led to the evolution of stereo vision, including range finding, camouflage breaking and estimation of object size. In this paper, we investigate the possibility that stereo vision enables praying mantises to estimate the size of prey by using a combination of disparity cues and angular size cues. We used a recently developed insect 3D cinema paradigm to present mantises with virtual prey having differing disparity and angular size cues. We predicted that if they were able to use these cues to gauge the absolute size of objects, we should see evidence for size constancy where they would strike preferentially at prey of a particular physical size, across a range of simulated distances. We found that mantises struck most often when disparity cues implied a prey distance of 2.5 cm; increasing the implied distance caused a significant reduction in the number of strikes. We, however, found no evidence for size constancy. There was a significant interaction effect of the simulated distance and angular size on the number of strikes made by the mantis but this was not in the direction predicted by size constancy. This indicates that mantises do not use their stereo vision to estimate object size. We conclude that other selective advantages, not size constancy, have driven the evolution of stereo vision in the praying mantis. This article is part of the themed issue ‘Vision in our three-dimensional world’. PMID:27269605
Visual search for arbitrary objects in real scenes
Alvarez, George A.; Rosenholtz, Ruth; Kuzmova, Yoana I.; Sherman, Ashley M.
2011-01-01
How efficient is visual search in real scenes? In searches for targets among arrays of randomly placed distractors, efficiency is often indexed by the slope of the reaction time (RT) × Set Size function. However, it may be impossible to define set size for real scenes. As an approximation, we hand-labeled 100 indoor scenes and used the number of labeled regions as a surrogate for set size. In Experiment 1, observers searched for named objects (a chair, bowl, etc.). With set size defined as the number of labeled regions, search was very efficient (~5 ms/item). When we controlled for a possible guessing strategy in Experiment 2, slopes increased somewhat (~15 ms/item), but they were much shallower than search for a random object among other distinctive objects outside of a scene setting (Exp. 3: ~40 ms/item). In Experiments 4–6, observers searched repeatedly through the same scene for different objects. Increased familiarity with scenes had modest effects on RTs, while repetition of target items had large effects (>500 ms). We propose that visual search in scenes is efficient because scene-specific forms of attentional guidance can eliminate most regions from the “functional set size” of items that could possibly be the target. PMID:21671156
The Surface-to-Volume Ratio in Thermal Physics: From Cheese Cube Physics to Animal Metabolism
ERIC Educational Resources Information Center
Planinsic, Gorazd; Vollmer, Michael
2008-01-01
The surface-to-volume ratio is an important quantity in thermal physics. For example it governs the behaviour of heating or cooling of physical objects as a function of size like, e.g. cubes or spheres made of different material. The starting point in our paper is the simple physics problem of how cheese cubes of different sizes behave if heated…
Is hefting to perceive the affordance for throwing a smart perceptual mechanism?
Zhu, Qin; Bingham, Geoffrey P
2008-08-01
G. P. Bingham, R. C. Schmidt, and L. D. Rosenblum (1989) found that, by hefting objects of different sizes and weights, people could choose the optimal weight in each size for throwing to a maximum distance. In Experiment 1, the authors replicated this result. G. P. Bingham et al. hypothesized that hefting is a smart mechanism that allows objects to be perceived in the context of throwing dynamics. This hypothesis entails 2 assumptions. First, hefting by hand is required for information about throwing by hand. The authors tested and confirmed this in Experiments 2 and 3. Second, optimal objects are determined by the dynamics of throwing. In Experiment 4, the authors tested this by measuring throwing release angles and using them with mean thrown distances from Experiment 1 and object sizes and weights to simulate projectile motion and recover release velocities. The results showed that only weight, not size, affects throwing. This failed to provide evidence supporting the particular smart mechanism hypothesis of G. P. Bingham et al. Because the affordance relation is determined in part by the dynamics of projectile motion, the results imply that the affordance is learned from knowledge of results of throwing.
Invariance of visual operations at the level of receptive fields
Lindeberg, Tony
2013-01-01
The brain is able to maintain a stable perception although the visual stimuli vary substantially on the retina due to geometric transformations and lighting variations in the environment. This paper presents a theory for achieving basic invariance properties already at the level of receptive fields. Specifically, the presented framework comprises (i) local scaling transformations caused by objects of different size and at different distances to the observer, (ii) locally linearized image deformations caused by variations in the viewing direction in relation to the object, (iii) locally linearized relative motions between the object and the observer and (iv) local multiplicative intensity transformations caused by illumination variations. The receptive field model can be derived by necessity from symmetry properties of the environment and leads to predictions about receptive field profiles in good agreement with receptive field profiles measured by cell recordings in mammalian vision. Indeed, the receptive field profiles in the retina, LGN and V1 are close to ideal to what is motivated by the idealized requirements. By complementing receptive field measurements with selection mechanisms over the parameters in the receptive field families, it is shown how true invariance of receptive field responses can be obtained under scaling transformations, affine transformations and Galilean transformations. Thereby, the framework provides a mathematically well-founded and biologically plausible model for how basic invariance properties can be achieved already at the level of receptive fields and support invariant recognition of objects and events under variations in viewpoint, retinal size, object motion and illumination. The theory can explain the different shapes of receptive field profiles found in biological vision, which are tuned to different sizes and orientations in the image domain as well as to different image velocities in space-time, from a requirement that the visual system should be invariant to the natural types of image transformations that occur in its environment. PMID:23894283
Canonical Visual Size for Real-World Objects
Konkle, Talia; Oliva, Aude
2012-01-01
Real-world objects can be viewed at a range of distances and thus can be experienced at a range of visual angles within the visual field. Given the large amount of visual size variation possible when observing objects, we examined how internal object representations represent visual size information. In a series of experiments which required observers to access existing object knowledge, we observed that real-world objects have a consistent visual size at which they are drawn, imagined, and preferentially viewed. Importantly, this visual size is proportional to the logarithm of the assumed size of the object in the world, and is best characterized not as a fixed visual angle, but by the ratio of the object and the frame of space around it. Akin to the previous literature on canonical perspective, we term this consistent visual size information the canonical visual size. PMID:20822298
A mass-density model can account for the size-weight illusion
Bergmann Tiest, Wouter M.; Drewing, Knut
2018-01-01
When judging the heaviness of two objects with equal mass, people perceive the smaller and denser of the two as being heavier. Despite the large number of theories, covering bottom-up and top-down approaches, none of them can fully account for all aspects of this size-weight illusion and thus for human heaviness perception. Here we propose a new maximum-likelihood estimation model which describes the illusion as the weighted average of two heaviness estimates with correlated noise: One estimate derived from the object’s mass, and the other from the object’s density, with estimates’ weights based on their relative reliabilities. While information about mass can directly be perceived, information about density will in some cases first have to be derived from mass and volume. However, according to our model at the crucial perceptual level, heaviness judgments will be biased by the objects’ density, not by its size. In two magnitude estimation experiments, we tested model predictions for the visual and the haptic size-weight illusion. Participants lifted objects which varied in mass and density. We additionally varied the reliability of the density estimate by varying the quality of either visual (Experiment 1) or haptic (Experiment 2) volume information. As predicted, with increasing quality of volume information, heaviness judgments were increasingly biased towards the object’s density: Objects of the same density were perceived as more similar and big objects were perceived as increasingly lighter than small (denser) objects of the same mass. This perceived difference increased with an increasing difference in density. In an additional two-alternative forced choice heaviness experiment, we replicated that the illusion strength increased with the quality of volume information (Experiment 3). Overall, the results highly corroborate our model, which seems promising as a starting point for a unifying framework for the size-weight illusion and human heaviness perception. PMID:29447183
Jacoby, Jason
2017-01-01
Retinal ganglion cells (RGCs) are frequently divided into functional types by their ability to extract and relay specific features from a visual scene, such as the capacity to discern local or global motion, direction of motion, stimulus orientation, contrast or uniformity, or the presence of large or small objects. Here we introduce three previously uncharacterized, nondirection-selective ON–OFF RGC types that represent a distinct set of feature detectors in the mouse retina. The three high-definition (HD) RGCs possess small receptive-field centers and strong surround suppression. They respond selectively to objects of specific sizes, speeds, and types of motion. We present comprehensive morphological characterization of the HD RGCs and physiological recordings of their light responses, receptive-field size and structure, and synaptic mechanisms of surround suppression. We also explore the similarities and differences between the HD RGCs and a well characterized RGC with a comparably small receptive field, the local edge detector, in response to moving objects and textures. We model populations of each RGC type to study how they differ in their performance tracking a moving object. These results, besides introducing three new RGC types that together constitute a substantial fraction of mouse RGCs, provide insights into the role of different circuits in shaping RGC receptive fields and establish a foundation for continued study of the mechanisms of surround suppression and the neural basis of motion detection. SIGNIFICANCE STATEMENT The output cells of the retina, retinal ganglion cells (RGCs), are a diverse group of ∼40 distinct neuron types that are often assigned “feature detection” profiles based on the specific aspects of the visual scene to which they respond. Here we describe, for the first time, morphological and physiological characterization of three new RGC types in the mouse retina, substantially augmenting our understanding of feature selectivity. Experiments and modeling show that while these three “high-definition” RGCs share certain receptive-field properties, they also have distinct tuning to the size, speed, and type of motion on the retina, enabling them to occupy different niches in stimulus space. PMID:28100743
NASA Astrophysics Data System (ADS)
Kovalenko, I. D.; Doressoundiram, A.; Lellouch, E.; Vilenius, E.; Müller, T.; Stansberry, J.
2017-11-01
Context. Gravitationally bound multiple systems provide an opportunity to estimate the mean bulk density of the objects, whereas this characteristic is not available for single objects. Being a primitive population of the outer solar system, binary and multiple trans-Neptunian objects (TNOs) provide unique information about bulk density and internal structure, improving our understanding of their formation and evolution. Aims: The goal of this work is to analyse parameters of multiple trans-Neptunian systems, observed with Herschel and Spitzer space telescopes. Particularly, statistical analysis is done for radiometric size and geometric albedo, obtained from photometric observations, and for estimated bulk density. Methods: We use Monte Carlo simulation to estimate the real size distribution of TNOs. For this purpose, we expand the dataset of diameters by adopting the Minor Planet Center database list with available values of the absolute magnitude therein, and the albedo distribution derived from Herschel radiometric measurements. We use the 2-sample Anderson-Darling non-parametric statistical method for testing whether two samples of diameters, for binary and single TNOs, come from the same distribution. Additionally, we use the Spearman's coefficient as a measure of rank correlations between parameters. Uncertainties of estimated parameters together with lack of data are taken into account. Conclusions about correlations between parameters are based on statistical hypothesis testing. Results: We have found that the difference in size distributions of multiple and single TNOs is biased by small objects. The test on correlations between parameters shows that the effective diameter of binary TNOs strongly correlates with heliocentric orbital inclination and with magnitude difference between components of binary system. The correlation between diameter and magnitude difference implies that small and large binaries are formed by different mechanisms. Furthermore, the statistical test indicates, although not significant with the sample size, that a moderately strong correlation exists between diameter and bulk density. Herschel is an ESA space observatory with science instruments provided by European-led Principal Investigator consortia and with important participation from NASA.
Uncertainty in Population Estimates for Endangered Animals and Improving the Recovery Process
Haines, Aaron M.; Zak, Matthew; Hammond, Katie; Scott, J. Michael; Goble, Dale D.; Rachlow, Janet L.
2013-01-01
Simple Summary The objective of our study was to evaluate the mention of uncertainty (i.e., variance) associated with population size estimates within U.S. recovery plans for endangered animals. To do this we reviewed all finalized recovery plans for listed terrestrial vertebrate species. We found that more recent recovery plans reported more estimates of population size and uncertainty. Also, bird and mammal recovery plans reported more estimates of population size and uncertainty. We recommend that updated recovery plans combine uncertainty of population size estimates with a minimum detectable difference to aid in successful recovery. Abstract United States recovery plans contain biological information for a species listed under the Endangered Species Act and specify recovery criteria to provide basis for species recovery. The objective of our study was to evaluate whether recovery plans provide uncertainty (e.g., variance) with estimates of population size. We reviewed all finalized recovery plans for listed terrestrial vertebrate species to record the following data: (1) if a current population size was given, (2) if a measure of uncertainty or variance was associated with current estimates of population size and (3) if population size was stipulated for recovery. We found that 59% of completed recovery plans specified a current population size, 14.5% specified a variance for the current population size estimate and 43% specified population size as a recovery criterion. More recent recovery plans reported more estimates of current population size, uncertainty and population size as a recovery criterion. Also, bird and mammal recovery plans reported more estimates of population size and uncertainty compared to reptiles and amphibians. We suggest the use of calculating minimum detectable differences to improve confidence when delisting endangered animals and we identified incentives for individuals to get involved in recovery planning to improve access to quantitative data. PMID:26479531
Scale-based fuzzy connectivity: a novel image segmentation methodology and its validation
NASA Astrophysics Data System (ADS)
Saha, Punam K.; Udupa, Jayaram K.
1999-05-01
This paper extends a previously reported theory and algorithms for fuzzy connected object definition. It introduces `object scale' for determining the neighborhood size for defining affinity, the degree of local hanging togetherness between image elements. Object scale allows us to use a varying neighborhood size in different parts of the image. This paper argues that scale-based fuzzy connectivity is natural in object definition and demonstrates that this leads to a more effective object segmentation than without using scale in fuzzy concentrations. Affinity is described as consisting of a homogeneity-based and an object-feature- based component. Families of non scale-based and scale-based affinity relations are constructed. An effective method for giving a rough estimate of scale at different locations in the image is presented. The original theoretical and algorithmic framework remains more-or-less the same but considerably improved segmentations result. A quantitative statistical comparison between the non scale-based and the scale-based methods was made based on phantom images generated from patient MR brain studies by first segmenting the objects, and then by adding noise and blurring, and background component. Both the statistical and the subjective tests clearly indicate the superiority of scale- based method in capturing details and in robustness to noise.
Practical implementation of channelized hotelling observers: effect of ROI size
NASA Astrophysics Data System (ADS)
Ferrero, Andrea; Favazza, Christopher P.; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H.
2017-03-01
Fundamental to the development and application of channelized Hotelling observer (CHO) models is the selection of the region of interest (ROI) to evaluate. For assessment of medical imaging systems, reducing the ROI size can be advantageous. Smaller ROIs enable a greater concentration of interrogable objects in a single phantom image, thereby providing more information from a set of images and reducing the overall image acquisition burden. Additionally, smaller ROIs may promote better assessment of clinical patient images as different patient anatomies present different ROI constraints. To this end, we investigated the minimum ROI size that does not compromise the performance of the CHO model. In this study, we evaluated both simulated images and phantom CT images to identify the minimum ROI size that resulted in an accurate figure of merit (FOM) of the CHO's performance. More specifically, the minimum ROI size was evaluated as a function of the following: number of channels, spatial frequency and number of rotations of the Gabor filters, size and contrast of the object, and magnitude of the image noise. Results demonstrate that a minimum ROI size exists below which the CHO's performance is grossly inaccurate. The minimum ROI size is shown to increase with number of channels and be dictated by truncation of lower frequency filters. We developed a model to estimate the minimum ROI size as a parameterized function of the number of orientations and spatial frequencies of the Gabor filters, providing a guide for investigators to appropriately select parameters for model observer studies.
Practical implementation of Channelized Hotelling Observers: Effect of ROI size.
Ferrero, Andrea; Favazza, Christopher P; Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H
2017-03-01
Fundamental to the development and application of channelized Hotelling observer (CHO) models is the selection of the region of interest (ROI) to evaluate. For assessment of medical imaging systems, reducing the ROI size can be advantageous. Smaller ROIs enable a greater concentration of interrogable objects in a single phantom image, thereby providing more information from a set of images and reducing the overall image acquisition burden. Additionally, smaller ROIs may promote better assessment of clinical patient images as different patient anatomies present different ROI constraints. To this end, we investigated the minimum ROI size that does not compromise the performance of the CHO model. In this study, we evaluated both simulated images and phantom CT images to identify the minimum ROI size that resulted in an accurate figure of merit (FOM) of the CHO's performance. More specifically, the minimum ROI size was evaluated as a function of the following: number of channels, spatial frequency and number of rotations of the Gabor filters, size and contrast of the object, and magnitude of the image noise. Results demonstrate that a minimum ROI size exists below which the CHO's performance is grossly inaccurate. The minimum ROI size is shown to increase with number of channels and be dictated by truncation of lower frequency filters. We developed a model to estimate the minimum ROI size as a parameterized function of the number of orientations and spatial frequencies of the Gabor filters, providing a guide for investigators to appropriately select parameters for model observer studies.
NASA Astrophysics Data System (ADS)
Shchuko, O. B.; Shchuko, S. D.; Kartashov, D.; Orosei, R.
2012-04-01
Thermal evolution of accretion-formed Kuiper Belt Objects (KBOs) with modern sizes from 200 to 2000 km and average densities from 1100 to 3200 kg/m3 has been studied by mathematical simulation methods. The values range of physical parameters of the accretion material and ultimate radionuclide content, securing KBO existence at present, have been found. The solid dust material of protosolar cloud fringe regions and fine-fractured H2O condensate in the form of amorphous ice are considered to have been the building matter for these objects. This material was represented by small dust particles of different chemical and mineralogical composition, embedded with radionuclides 238U, 235U, 232Th, 40K providing the sources of radiogenic heat. H2O condensate secured the presence of amorphous ice in the forming body's matter. Radiogenic heat leads to H2O phase transitions which define a body's interior matter differentiation. The radionuclide content at the initial time of the body formation determined the dynamically changing degree of the interior matter differentiation at different KBO depths for the whole period from the initial up to the present time. For the models of the celestial objects considered, the dynamically changing boundaries of spherically symmetric regions with different degree of matter differentiation have been determined.
Buried Object Detection Method Using Optimum Frequency Range in Extremely Shallow Underground
NASA Astrophysics Data System (ADS)
Sugimoto, Tsuneyoshi; Abe, Touma
2011-07-01
We propose a new detection method for buried objects using the optimum frequency response range of the corresponding vibration velocity. Flat speakers and a scanning laser Doppler vibrometer (SLDV) are used for noncontact acoustic imaging in the extremely shallow underground. The exploration depth depends on the sound pressure, but it is usually less than 10 cm. Styrofoam, wood (silver fir), and acrylic boards of the same size, different size styrofoam boards, a hollow toy duck, a hollow plastic container, a plastic container filled with sand, a hollow steel can and an unglazed pot are used as buried objects which are buried in sand to about 2 cm depth. The imaging procedure of buried objects using the optimum frequency range is given below. First, the standardized difference from the average vibration velocity is calculated for all scan points. Next, using this result, underground images are made using a constant frequency width to search for the frequency response range of the buried object. After choosing an approximate frequency response range, the difference between the average vibration velocity for all points and that for several points that showed a clear response is calculated for the final confirmation of the optimum frequency range. Using this optimum frequency range, we can obtain the clearest image of the buried object. From the experimental results, we confirmed the effectiveness of our proposed method. In particular, a clear image of the buried object was obtained when the SLDV image was unclear.
Systematic evaluation of deep learning based detection frameworks for aerial imagery
NASA Astrophysics Data System (ADS)
Sommer, Lars; Steinmann, Lucas; Schumann, Arne; Beyerer, Jürgen
2018-04-01
Object detection in aerial imagery is crucial for many applications in the civil and military domain. In recent years, deep learning based object detection frameworks significantly outperformed conventional approaches based on hand-crafted features on several datasets. However, these detection frameworks are generally designed and optimized for common benchmark datasets, which considerably differ from aerial imagery especially in object sizes. As already demonstrated for Faster R-CNN, several adaptations are necessary to account for these differences. In this work, we adapt several state-of-the-art detection frameworks including Faster R-CNN, R-FCN, and Single Shot MultiBox Detector (SSD) to aerial imagery. We discuss adaptations that mainly improve the detection accuracy of all frameworks in detail. As the output of deeper convolutional layers comprise more semantic information, these layers are generally used in detection frameworks as feature map to locate and classify objects. However, the resolution of these feature maps is insufficient for handling small object instances, which results in an inaccurate localization or incorrect classification of small objects. Furthermore, state-of-the-art detection frameworks perform bounding box regression to predict the exact object location. Therefore, so called anchor or default boxes are used as reference. We demonstrate how an appropriate choice of anchor box sizes can considerably improve detection performance. Furthermore, we evaluate the impact of the performed adaptations on two publicly available datasets to account for various ground sampling distances or differing backgrounds. The presented adaptations can be used as guideline for further datasets or detection frameworks.
Genital size: a common adolescent male concern.
Lee, Peter A; Reiter, Edward O
2002-02-01
Long before adolescence, males hear insinuations about adequacy of penis size. This concern may heighten during teen years and persist to varying degrees into adulthood. Men tend to underestimate their own penis size. This chapter provides objective information about anatomy and growth of the penis, including data about normal sizes. Published data indicate that, although full growth may be reached at different ages during adolescence, size is similar for most adult males. Hopefully, this information will provide the basis for teenaged males to develop a healthy perspective and to avoid intimidation by unfounded claims about sexual enhancement or size enlargement techniques.
A NDVI assisted remote sensing image adaptive scale segmentation method
NASA Astrophysics Data System (ADS)
Zhang, Hong; Shen, Jinxiang; Ma, Yanmei
2018-03-01
Multiscale segmentation of images can effectively form boundaries of different objects with different scales. However, for the remote sensing image which widely coverage with complicated ground objects, the number of suitable segmentation scales, and each of the scale size is still difficult to be accurately determined, which severely restricts the rapid information extraction of the remote sensing image. A great deal of experiments showed that the normalized difference vegetation index (NDVI) can effectively express the spectral characteristics of a variety of ground objects in remote sensing images. This paper presents a method using NDVI assisted adaptive segmentation of remote sensing images, which segment the local area by using NDVI similarity threshold to iteratively select segmentation scales. According to the different regions which consist of different targets, different segmentation scale boundaries could be created. The experimental results showed that the adaptive segmentation method based on NDVI can effectively create the objects boundaries for different ground objects of remote sensing images.
Retrieving optical constants of glasses with variable iron abundance
NASA Astrophysics Data System (ADS)
Carli, C.; Roush, T. L.; Capaccioni, F.; Baraldi, A.
2013-12-01
Visible and Near Infrared (VNIR, ~0.4-2.5 μm) spectroscopy is an important tool to explore the surface composition of objects in our Solar System. Using this technique different minerals have been recognized on the surfaces of solar system bodies. One of the principal products of extrusive volcanism and impact cratering is a glassy component, that can be abundant and thus significantly influence the spectral signature of the region investigated. Different types of glasses have been proposed and identified on the lunar surface and in star forming regions near young stellar objects. Here we report an initial effort of retrieving the optical constants of volcanic glasses formed in oxidizing terrestrial-like conditions. We also investigated how those calculations are affected by the grain size distribution. Bidirectional reflectance spectra, obtained with incidence and emission angles of 30° and 0°, respectively, were measured on powders of different grain sizes for four different glassy compositions in the VNIR. Hapke's model of the interaction of light with particulate surfaces was used to determine the imaginary index, k, at each wavelength by iteratively minimizing the difference between measured and calculated reflectance The basic approach to retrieving the optical constants was to use multiple grain sizes of the same sample and assume all grain sizes are compositionally equivalent. Unless independently known as a function of wavelength, an additional assumption must be made regarding the real index of refraction, n. The median size for each particle size separate was adopted for initially estimating k. Then, iterating the Hapke analysis results with a subtractive Kramers-Kronig analysis we were able to determine the wavelength dependence of n. For each composition we used the k-values estimated for all the grain sizes to calculate a mean k-value representing that composition. These values were then used to fit the original spectra by only varying the grain sizes. As a separate estimate of the k-values, we will use transmission measurements in the VNIR. Two slabs, with different thicknesses, will be measured for each composition. These data will be used to determine a k value and a comparison between k values obtained from the two different techniques will be discussed.
Baode Wang; David R. Lance; Joseph A. Francese; Zhichun Xu; Fengyong Jia; Youqing Luo; Victor C. Mastro
2003-01-01
Silhouettes of different colors, shapes and sizes made of bamboo frames covered with cloth, paired in different color sets, were placed equidistantly around the perimeter of a circle with a 7.5 m radius, in an open area.
Assessment of Different Biofilter Media Particle Sizes for Ammonia Removal Optimization
USDA-ARS?s Scientific Manuscript database
The main objective of this study is to determine a range of particle sizes that provides low resistance to the air flow but also sufficient surface area for microbial attachment, which is needed for higher biofiltration efficiency. This will be done by assessing ammonia removal and pressure drop in ...
Dynamical features of hazardous near-Earth objects
NASA Astrophysics Data System (ADS)
Emel'yanenko, V. V.; Naroenkov, S. A.
2015-07-01
We discuss the dynamical features of near-Earth objects moving in dangerous proximity to Earth. We report the computation results for the motions of all observed near-Earth objects over a 600-year-long time period: 300 years in the past and 300 years in the future. We analyze the dynamical features of Earth-approaching objects. In particular, we established that the observed distribution of geocentric velocities of dangerous objects depends on their size. No bodies with geocentric velocities smaller that 5 kms-1 have been found among hazardous objects with absolute magnitudes H <18, whereas 9% of observed objects with H <27 pass near Earth moving at such velocities. On the other hand, we found a tendency for geocentric velocities to increase at H >29. We estimated the distribution of absolute magnitudes of hazardous objects based on our analysis of the data for the asteroids that have passed close to Earth. We inferred the Earth-impact frequencies for objects of different sizes. Impacts of objects with H <18 with Earth occur on average once every 0.53 Myr, and impacts of objects with H <27—once every 130-240 years. We show that currently about 0.1% of all near-Earth objects with diameters greater than 10 m have been discovered. We point out the discrepancies between the estimates of impact rates of Chelyabinsk-type objects, determined from fireball observations and from the data of telescopic asteroid tracking surveys. These estimates can be reconciled assuming that Chelyabinsk-sized asteroids have very low albedos (about 0.02 on average).
NASA Astrophysics Data System (ADS)
Chi, Sheng; Lee, Shu-Sheng; Huang, Jen, Jen-Yu; Lai, Ti-Yu; Jan, Chia-Ming; Hu, Po-Chi
2016-04-01
As the progress of optical technologies, different commercial 3D surface contour scanners are on the market nowadays. Most of them are used for reconstructing the surface profile of mold or mechanical objects which are larger than 50 mm×50 mm× 50 mm, and the scanning system size is about 300 mm×300 mm×100 mm. There are seldom optical systems commercialized for surface profile fast scanning for small object size less than 10 mm×10 mm×10 mm. Therefore, a miniature optical system has been designed and developed in this research work for this purpose. Since the most used scanning method of such system is line scan technology, we have developed pseudo-phase shifting digital projection technology by adopting projecting fringes and phase reconstruction method. A projector was used to project a digital fringe patterns on the object, and the fringes intensity images of the reference plane and of the sample object were recorded by a CMOS camera. The phase difference between the plane and object can be calculated from the fringes images, and the surface profile of the object was reconstructed by using the phase differences. The traditional phase shifting method was accomplished by using PZT actuator or precisely controlled motor to adjust the light source or grating and this is one of the limitations for high speed scanning. Compared with the traditional optical setup, we utilized a micro projector to project the digital fringe patterns on the sample. This diminished the phase shifting processing time and the controlled phase differences between the shifted phases become more precise. Besides, the optical path design based on a portable device scanning system was used to minimize the size and reduce the number of the system components. A screwdriver section about 7mm×5mm×5mm has been scanned and its surface profile was successfully restored. The experimental results showed that the measurement area of our system can be smaller than 10mm×10mm, the precision reached to +/-10μm, and the scanning time for each surface of an object was less than 15 seconds. This has proved that our system own the potential to be a fast scanning scanner for small object surface profile scanning.
Rey, Amandine Eve; Riou, Benoit; Versace, Rémy
2014-01-01
Based on recent behavioral and neuroimaging data suggesting that memory and perception are partially based on the same sensorimotor system, the theoretical aim of the present study was to show that it is difficult to dissociate memory mechanisms from perceptual mechanisms other than on the basis of the presence (perceptual processing) or absence (memory processing) of the characteristics of the objects involved in the processing. In line with this assumption, two experiments using an adaptation of the Ebbinghaus illusion paradigm revealed similar effects irrespective of whether the size difference between the inner circles and the surrounding circles was manipulated perceptually (the size difference was perceptually present, Experiment 1) or merely reactivated in memory (the difference was perceptually absent, Experiment 2).
Online phase measuring profilometry for rectilinear moving object by image correction
NASA Astrophysics Data System (ADS)
Yuan, Han; Cao, Yi-Ping; Chen, Chen; Wang, Ya-Pin
2015-11-01
In phase measuring profilometry (PMP), the object must be static for point-to-point reconstruction with the captured deformed patterns. While the object is rectilinearly moving online, the size and pixel position differences of the object in different captured deformed patterns do not meet the point-to-point requirement. We propose an online PMP based on image correction to measure the three-dimensional shape of the rectilinear moving object. In the proposed method, the deformed patterns captured by a charge-coupled diode camera are reprojected from the oblique view to an aerial view first and then translated based on the feature points of the object. This method makes the object appear stationary in the deformed patterns. Experimental results show the feasibility and efficiency of the proposed method.
Mid-level perceptual features contain early cues to animacy.
Long, Bria; Störmer, Viola S; Alvarez, George A
2017-06-01
While substantial work has focused on how the visual system achieves basic-level recognition, less work has asked about how it supports large-scale distinctions between objects, such as animacy and real-world size. Previous work has shown that these dimensions are reflected in our neural object representations (Konkle & Caramazza, 2013), and that objects of different real-world sizes have different mid-level perceptual features (Long, Konkle, Cohen, & Alvarez, 2016). Here, we test the hypothesis that animates and manmade objects also differ in mid-level perceptual features. To do so, we generated synthetic images of animals and objects that preserve some texture and form information ("texforms"), but are not identifiable at the basic level. We used visual search efficiency as an index of perceptual similarity, as search is slower when targets are perceptually similar to distractors. Across three experiments, we find that observers can find animals faster among objects than among other animals, and vice versa, and that these results hold when stimuli are reduced to unrecognizable texforms. Electrophysiological evidence revealed that this mixed-animacy search advantage emerges during early stages of target individuation, and not during later stages associated with semantic processing. Lastly, we find that perceived curvature explains part of the mixed-animacy search advantage and that observers use perceived curvature to classify texforms as animate/inanimate. Taken together, these findings suggest that mid-level perceptual features, including curvature, contain cues to whether an object may be animate versus manmade. We propose that the visual system capitalizes on these early cues to facilitate object detection, recognition, and classification.
Chen, Juan; Sperandio, Irene; Goodale, Melvyn Alan
2018-03-19
Our brain integrates information from multiple modalities in the control of behavior. When information from one sensory source is compromised, information from another source can compensate for the loss. What is not clear is whether the nature of this multisensory integration and the re-weighting of different sources of sensory information are the same across different control systems. Here, we investigated whether proprioceptive distance information (position sense of body parts) can compensate for the loss of visual distance cues that support size constancy in perception (mediated by the ventral visual stream) [1, 2] versus size constancy in grasping (mediated by the dorsal visual stream) [3-6], in which the real-world size of an object is computed despite changes in viewing distance. We found that there was perfect size constancy in both perception and grasping in a full-viewing condition (lights on, binocular viewing) and that size constancy in both tasks was dramatically disrupted in the restricted-viewing condition (lights off; monocular viewing of the same but luminescent object through a 1-mm pinhole). Importantly, in the restricted-viewing condition, proprioceptive cues about viewing distance originating from the non-grasping limb (experiment 1) or the inclination of the torso and/or the elbow angle of the grasping limb (experiment 2) compensated for the loss of visual distance cues to enable a complete restoration of size constancy in grasping but only a modest improvement of size constancy in perception. This suggests that the weighting of different sources of sensory information varies as a function of the control system being used. Copyright © 2018 Elsevier Ltd. All rights reserved.
The Identity-Location Binding Problem.
Howe, Piers D L; Ferguson, Adam
2015-09-01
The binding problem is fundamental to visual perception. It is the problem of associating an object's visual properties with itself and not with some other object. The problem is made particular difficult because different properties of an object, such as its color, shape, size, and motion, are often processed independently, sometimes in different cortical areas. The results of these separate analyses have to be combined before the object can be seen as a single coherent entity as opposed to a collection of unconnected features. Visual bindings are typically initiated and updated in a serial fashion, one object at a time. Here, we show that one type of binding, location-identity bindings, can be updated in parallel. We do this by using two complementary techniques, the simultaneous-sequential paradigm and systems factorial technology. These techniques make different assumptions and rely on different behavioral measures, yet both came to the same conclusion. Copyright © 2014 Cognitive Science Society, Inc.
Ibrahim, Mohd Rasdan; Katman, Herda Yati; Karim, Mohamed Rehan; Koting, Suhana; Mashaan, Nuha S
2014-01-01
The main objective of this paper is to investigate the relations of rubber size, rubber content, and binder content in determination of optimum binder content for open graded friction course (OGFC). Mix gradation type B as specified in Specification for Porous Asphalt produced by the Road Engineering Association of Malaysia (REAM) was used in this study. Marshall specimens were prepared with four different sizes of rubber, namely, 20 mesh size [0.841 mm], 40 mesh [0.42 mm], 80 mesh [0.177 mm], and 100 mesh [0.149 mm] with different concentrations of rubberised bitumen (4%, 8%, and 12%) and different percentages of binder content (4%-7%). The appropriate optimum binder content is then selected according to the results of the air voids, binder draindown, and abrasion loss test. Test results found that crumb rubber particle size can affect the optimum binder content for OGFC.
The Effects of Age and Set Size on the Fast Extraction of Egocentric Distance
Gajewski, Daniel A.; Wallin, Courtney P.; Philbeck, John W.
2016-01-01
Angular direction is a source of information about the distance to floor-level objects that can be extracted from brief glimpses (near one's threshold for detection). Age and set size are two factors known to impact the viewing time needed to directionally localize an object, and these were posited to similarly govern the extraction of distance. The question here was whether viewing durations sufficient to support object detection (controlled for age and set size) would also be sufficient to support well-constrained judgments of distance. Regardless of viewing duration, distance judgments were more accurate (less biased towards underestimation) when multiple potential targets were presented, suggesting that the relative angular declinations between the objects are an additional source of useful information. Distance judgments were more precise with additional viewing time, but the benefit did not depend on set size and accuracy did not improve with longer viewing durations. The overall pattern suggests that distance can be efficiently derived from direction for floor-level objects. Controlling for age-related differences in the viewing time needed to support detection was sufficient to support distal localization but only when brief and longer glimpse trials were interspersed. Information extracted from longer glimpse trials presumably supported performance on subsequent trials when viewing time was more limited. This outcome suggests a particularly important role for prior visual experience in distance judgments for older observers. PMID:27398065
Khaligh-Razavi, Seyed-Mahdi; Cichy, Radoslaw Martin; Pantazis, Dimitrios; Oliva, Aude
2018-06-07
Animacy and real-world size are properties that describe any object and thus bring basic order into our perception of the visual world. Here, we investigated how the human brain processes real-world size and animacy. For this, we applied representational similarity to fMRI and MEG data to yield a view of brain activity with high spatial and temporal resolutions, respectively. Analysis of fMRI data revealed that a distributed and partly overlapping set of cortical regions extending from occipital to ventral and medial temporal cortex represented animacy and real-world size. Within this set, parahippocampal cortex stood out as the region representing animacy and size stronger than most other regions. Further analysis of the detailed representational format revealed differences among regions involved in processing animacy. Analysis of MEG data revealed overlapping temporal dynamics of animacy and real-world size processing starting at around 150 msec and provided the first neuromagnetic signature of real-world object size processing. Finally, to investigate the neural dynamics of size and animacy processing simultaneously in space and time, we combined MEG and fMRI with a novel extension of MEG-fMRI fusion by representational similarity. This analysis revealed partly overlapping and distributed spatiotemporal dynamics, with parahippocampal cortex singled out as a region that represented size and animacy persistently when other regions did not. Furthermore, the analysis highlighted the role of early visual cortex in representing real-world size. A control analysis revealed that the neural dynamics of processing animacy and size were distinct from the neural dynamics of processing low-level visual features. Together, our results provide a detailed spatiotemporal view of animacy and size processing in the human brain.
Lu, Chen; Zhao, Xiaodan; Kawamura, Ryo
2017-01-01
Frictional drag force on an object in Stokes flow follows a linear relationship with the velocity of translation and a translational drag coefficient. This drag coefficient is related to the size, shape, and orientation of the object. For rod-like objects, analytical solutions of the drag coefficients have been proposed based on three rough approximations of the rod geometry, namely the bead model, ellipsoid model, and cylinder model. These theories all agree that translational drag coefficients of rod-like objects are functions of the rod length and aspect ratio, but differ among one another on the correction factor terms in the equations. By tracking the displacement of the particles through stationary fluids of calibrated viscosity in magnetic tweezers setup, we experimentally measured the drag coefficients of micron-sized beads and their bead-chain formations with chain length of 2 to 27. We verified our methodology with analytical solutions of dimers of two touching beads, and compared our measured drag coefficient values of rod-like objects with theoretical calculations. Our comparison reveals several analytical solutions that used more appropriate approximation and derived formulae that agree with our measurement better. PMID:29145447
Cross-Sensory Correspondences: Heaviness is Dark and Low-Pitched.
Walker, Peter; Scallon, Gabrielle; Francis, Brian
2017-07-01
Everyday language reveals how stimuli encoded in one sensory feature domain can possess qualities normally associated with a different domain (e.g., higher pitch sounds are bright, light in weight, sharp, and thin). Such cross-sensory associations appear to reflect crosstalk among aligned (corresponding) feature dimensions, including brightness, heaviness, and sharpness. Evidence for heaviness being one such dimension is very limited, with heaviness appearing primarily as a verbal associate of other feature contrasts (e.g., darker objects and lower pitch sounds are heavier than their opposites). Given the presumed bidirectionality of the crosstalk between corresponding dimensions, heaviness should itself induce the cross-sensory associations observed elsewhere, including with brightness and pitch. Taking care to dissociate effects arising from the size and mass of an object, this is confirmed. When hidden objects varying independently in size and mass are lifted, objects that feel heavier are judged to be darker and to make lower pitch sounds than objects feeling less heavy. These judgements track the changes in perceived heaviness induced by the size-weight illusion. The potential involvement of language, natural scene statistics, and Bayesian processes in correspondences, and the effects they induce, is considered.
An approach to detecting deliberately introduced defects and micro-defects in 3D printed objects
NASA Astrophysics Data System (ADS)
Straub, Jeremy
2017-05-01
In prior work, Zeltmann, et al. demonstrated the negative impact that can be created by defects of various sizes in 3D printed objects. These defects may make the object unsuitable for its application or even present a hazard, if the object is being used for a safety-critical application. With the uses of 3D printing proliferating and consumer access to printers increasing, the desire of a nefarious individual or group to subvert the desired printing quality and safety attributes of a printer or printed object must be considered. Several different approaches to subversion may exist. Attackers may physically impair the functionality of the printer or launch a cyber-attack. Detecting introduced defects, from either attack, is critical to maintaining public trust in 3D printed objects and the technology. This paper presents an alternate approach. It applies a quality assurance technology based on visible light sensing to this challenge and assesses its capability for detecting introduced defects of multiple sizes.
Low-complexity object detection with deep convolutional neural network for embedded systems
NASA Astrophysics Data System (ADS)
Tripathi, Subarna; Kang, Byeongkeun; Dane, Gokce; Nguyen, Truong
2017-09-01
We investigate low-complexity convolutional neural networks (CNNs) for object detection for embedded vision applications. It is well-known that consolidation of an embedded system for CNN-based object detection is more challenging due to computation and memory requirement comparing with problems like image classification. To achieve these requirements, we design and develop an end-to-end TensorFlow (TF)-based fully-convolutional deep neural network for generic object detection task inspired by one of the fastest framework, YOLO.1 The proposed network predicts the localization of every object by regressing the coordinates of the corresponding bounding box as in YOLO. Hence, the network is able to detect any objects without any limitations in the size of the objects. However, unlike YOLO, all the layers in the proposed network is fully-convolutional. Thus, it is able to take input images of any size. We pick face detection as an use case. We evaluate the proposed model for face detection on FDDB dataset and Widerface dataset. As another use case of generic object detection, we evaluate its performance on PASCAL VOC dataset. The experimental results demonstrate that the proposed network can predict object instances of different sizes and poses in a single frame. Moreover, the results show that the proposed method achieves comparative accuracy comparing with the state-of-the-art CNN-based object detection methods while reducing the model size by 3× and memory-BW by 3 - 4× comparing with one of the best real-time CNN-based object detectors, YOLO. Our 8-bit fixed-point TF-model provides additional 4× memory reduction while keeping the accuracy nearly as good as the floating-point model. Moreover, the fixed- point model is capable of achieving 20× faster inference speed comparing with the floating-point model. Thus, the proposed method is promising for embedded implementations.
NASA Astrophysics Data System (ADS)
Grulke, Eric A.; Wu, Xiaochun; Ji, Yinglu; Buhr, Egbert; Yamamoto, Kazuhiro; Song, Nam Woong; Stefaniak, Aleksandr B.; Schwegler-Berry, Diane; Burchett, Woodrow W.; Lambert, Joshua; Stromberg, Arnold J.
2018-04-01
Size and shape distributions of gold nanorod samples are critical to their physico-chemical properties, especially their longitudinal surface plasmon resonance. This interlaboratory comparison study developed methods for measuring and evaluating size and shape distributions for gold nanorod samples using transmission electron microscopy (TEM) images. The objective was to determine whether two different samples, which had different performance attributes in their application, were different with respect to their size and/or shape descriptor distributions. Touching particles in the captured images were identified using a ruggedness shape descriptor. Nanorods could be distinguished from nanocubes using an elongational shape descriptor. A non-parametric statistical test showed that cumulative distributions of an elongational shape descriptor, that is, the aspect ratio, were statistically different between the two samples for all laboratories. While the scale parameters of size and shape distributions were similar for both samples, the width parameters of size and shape distributions were statistically different. This protocol fulfills an important need for a standardized approach to measure gold nanorod size and shape distributions for applications in which quantitative measurements and comparisons are important. Furthermore, the validated protocol workflow can be automated, thus providing consistent and rapid measurements of nanorod size and shape distributions for researchers, regulatory agencies, and industry.
Linking actions and objects: Context-specific learning of novel weight priors.
Trewartha, Kevin M; Flanagan, J Randall
2017-06-01
Distinct explicit and implicit memory processes support weight predictions used when lifting objects and making perceptual judgments about weight, respectively. The first time that an object is encountered weight is predicted on the basis of learned associations, or priors, linking size and material to weight. A fundamental question is whether the brain maintains a single, global representation of priors, or multiple representations that can be updated in a context specific way. A second key question is whether the updating of priors, or the ability to scale lifting forces when repeatedly lifting unusually weighted objects requires focused attention. To investigate these questions we compared the adaptability of weight predictions used when lifting objects and judging their weights in different groups of participants who experienced size-weight inverted objects passively (with the objects placed on the hands) or actively (where participants lift the objects) under full or divided attention. To assess weight judgments we measured the size-weight illusion after every 20 trials of experience with the inverted objects both passively and actively. The attenuation of the illusion that arises when lifting inverted object was found to be context-specific such that the attenuation was larger when the mode of interaction with the inverted objects matched the method of assessment of the illusion. Dividing attention during interaction with the inverted objects had no effect on attenuation of the illusion, but did slow the rate at which lifting forces were scaled to the weight inverted objects. These findings suggest that the brain stores multiple representations of priors that are context specific, and that focused attention is important for scaling lifting forces, but not for updating weight predictions used when judging object weight. Copyright © 2017 Elsevier B.V. All rights reserved.
Launders, J H; McArdle, S; Workman, A; Cowen, A R
1995-01-01
The significance of varying the viewing conditions that may affect the perceived threshold contrast of X-ray television fluoroscopy systems has been investigated. Factors investigated include the ambient room lighting and the viewing distance. The purpose of this study is to find the optimum viewing protocol with which to measure the threshold detection index. This is a particular problem when trying to compare the image quality of television fluoroscopy systems in different input field sizes. The results show that the viewing distance makes a significant difference to the perceived threshold contrast, whereas the ambient light conditions make no significant difference. Experienced observers were found to be capable of finding the optimum viewing distance for detecting details of each size, in effect using a flexible viewing distance. This allows the results from different field sizes to be normalized to account for both the magnification and the entrance air kerma rate differences, which in turn allow for a direct comparison of performance in different field sizes.
Structured-illumination reflectance imaging (SIRI) for enhanced detection of fresh bruises in apples
USDA-ARS?s Scientific Manuscript database
A structured-illumination reflectance imaging technique was developed for the detection of fresh bruises in apples. Experiments were first conducted on a strongly scattering nylon sample embedded with foreign objects of different sizes at different depths, and then on apples of two different cultiva...
How large is large? Identifying large corporate ownerships in FIA datasets
Jesse Caputo; Brett Butler; Andy Hartsell
2017-01-01
Forest ownership size is a continuous variable, albeit one with a distinctly nonnormal distribution. Although large corporate forest ownerships are expected to differ in terms of behavior and objectives from smaller corporate ownerships, there is no clear and unambiguous means of defined these two ownership groups. We examined the distribution of the ownership size...
Practical implementation of Channelized Hotelling Observers: Effect of ROI size
Yu, Lifeng; Leng, Shuai; McCollough, Cynthia H.
2017-01-01
Fundamental to the development and application of channelized Hotelling observer (CHO) models is the selection of the region of interest (ROI) to evaluate. For assessment of medical imaging systems, reducing the ROI size can be advantageous. Smaller ROIs enable a greater concentration of interrogable objects in a single phantom image, thereby providing more information from a set of images and reducing the overall image acquisition burden. Additionally, smaller ROIs may promote better assessment of clinical patient images as different patient anatomies present different ROI constraints. To this end, we investigated the minimum ROI size that does not compromise the performance of the CHO model. In this study, we evaluated both simulated images and phantom CT images to identify the minimum ROI size that resulted in an accurate figure of merit (FOM) of the CHO’s performance. More specifically, the minimum ROI size was evaluated as a function of the following: number of channels, spatial frequency and number of rotations of the Gabor filters, size and contrast of the object, and magnitude of the image noise. Results demonstrate that a minimum ROI size exists below which the CHO’s performance is grossly inaccurate. The minimum ROI size is shown to increase with number of channels and be dictated by truncation of lower frequency filters. We developed a model to estimate the minimum ROI size as a parameterized function of the number of orientations and spatial frequencies of the Gabor filters, providing a guide for investigators to appropriately select parameters for model observer studies. PMID:28943699
Organizing and Typing Persistent Objects Within an Object-Oriented Framework
NASA Technical Reports Server (NTRS)
Madany, Peter W.; Campbell, Roy H.
1991-01-01
Conventional operating systems provide little or no direct support for the services required for an efficient persistent object system implementation. We have built a persistent object scheme using a customization and extension of an object-oriented operating system called Choices. Choices includes a framework for the storage of persistent data that is suited to the construction of both conventional file system and persistent object system. In this paper we describe three areas in which persistent object support differs from file system support: storage organization, storage management, and typing. Persistent object systems must support various sizes of objects efficiently. Customizable containers, which are themselves persistent objects and can be nested, support a wide range of object sizes in Choices. Collections of persistent objects that are accessed as an aggregate and collections of light-weight persistent objects can be clustered in containers that are nested within containers for larger objects. Automated garbage collection schemes are added to storage management and have a major impact on persistent object applications. The Choices persistent object store provides extensible sets of persistent object types. The store contains not only the data for persistent objects but also the names of the classes to which they belong and the code for the operation of the classes. Besides presenting persistent object storage organization, storage management, and typing, this paper discusses how persistent objects are named and used within the Choices persistent data/file system framework.
Non-singular cloaks allow mimesis
NASA Astrophysics Data System (ADS)
Diatta, André; Guenneau, Sébastien
2011-02-01
We design non-singular cloaks enabling objects to scatter waves like objects with smaller size and very different shapes. We consider the Schrödinger equation, which is valid, for example, in the contexts of geometrical and quantum optics. More precisely, we introduce a generalized non-singular transformation for star domains, and numerically demonstrate that an object of nearly any given shape surrounded by a given cloak scatters waves in exactly the same way as a smaller object of another shape. When a source is located inside the cloak, it scatters waves as if it were located some distance away from a small object. Moreover, the invisibility region actually hosts almost trapped eigenstates. Mimetism is numerically shown to break down for the quantified energies associated with confined modes. If we further allow for non-isomorphic transformations, our approach leads to the design of quantum super-scatterers: a small size object surrounded by a quantum cloak described by a negative anisotropic heterogeneous effective mass and a negative spatially varying potential scatters matter waves like a larger nano-object of different shape. Potential applications might be, for instance, in quantum dots probing. The results in this paper, as well as the corresponding derived constitutive tensors, are valid for cloaks with any arbitrary star-shaped boundary cross sections, although for numerical simulations we use examples with piecewise linear or elliptic boundaries.
Differential force balances during levitation
NASA Astrophysics Data System (ADS)
Todd, Paul
The simplest arithmetic of inertial, buoyant, magnetic and electrokinetic levitation is explored in the context of a model living system with “acceleration-sensitive structures” in which motion, if allowed, produces a biological effect. The simple model is a finite-sized object enclosed within another finite-sized object suspended in an outer fluid (liquid or vapor) medium. The inner object has density and electrical and magnetic properties quantitatively different from those of the outer object and the medium. In inertial levitation (“weightlessness”) inertial accelerations are balanced, and the forces due to them are canceled in accordance with Newton’s third law. In the presence of inertial acceleration (gravity, centrifugal) motionlessness depends on a balance between the levitating force and the inertial force. If the inner and outer objects differ in density one or the other will be subjected to an unbalanced force when one object is levitated by any other force (buoyant, magnetic, electrokinetic). The requirements for motionlessness of the internal object in the presence of a levitating force are equality of density in the case of buoyant levitation, equality of magnetic susceptibility in the case of magnetic levitation, and equality of zeta potential and dielectric constant in the case of electrokinetic levitation. Examples of internal “acceleration-sensitive structures” are cellular organelles and the organs of advanced plants and animals. For these structures fundamental physical data are important in the interpretation of the effects of forces used for levitation.
Characterization of manufactured TiO2 nanoparticles
NASA Astrophysics Data System (ADS)
Motzkus, C.; Macé, T.; Vaslin-Reimann, S.; Ausset, P.; Maillé, M.
2013-04-01
Technological advances in nanomaterials have allowed the development of new applications in industry, increasing the probability of finding airborne manufactured and engineered nano-objects in the workplace, as well as in ambient air. Scientific studies on health and environmental risks have indicated that airborne nano-objects in ambient air have potential adverse effects on the health of exposed workers and the general population. For regulatory purposes, ambient measurements of particulate matter are based on the determination of mass concentrations for PM10 and PM2.5, as regulated in the European Directive 2008/50/EC. However, this legislation is not suitable for airborne manufactured and engineered nano-objects. Parameters characterising ultrafine particles, such as particle number concentration and size distribution, are under consideration for future health-based legislation, to monitor workplaces and to control industrial processes. Currently, there are no existing regulations covering manufactured airborne nano-objects. There is therefore a clear, unaddressed need to focus on the toxicology and exposure assessment of nano-objects such as titanium dioxide (TiO2), which are manufactured and engineered in large quantities in industry. To perform reliable toxicology studies it is necessary to determine the relevant characteristics of nano-objects, such as morphology, surface area, agglomeration, chemical composition, particle size and concentration, by applying traceable methods. Manufacturing of nanomaterials, and their use in industrial applications, also require traceable characterisation of the nanomaterials, particularly for quality control of the process. The present study arises from the OECD WPMN sponsorship programme, supported by the French Agency for Environmental and Occupational Health Safety (ANSES), in order to develop analytical methods for the characterization of TiO2 nanoparticles in size and count size distribution, based on different techniques to characterize five different manufactured TiO2 nanoparticles. In this study, different measurement techniques have been implemented: Transmission Electron Microscopy (TEM), Scanning Mobility Particle Sizer (SMPS) and Aerodynamic Particle Sizer (APS). The TEM results lead to a relatively good agreement between data from the manufacturer and our characterizations of primary particle size. With regard to the dustiness, the results show a strong presence of agglomerates / aggregates of primary particles and a significant presence of emitted airborne nanoparticles with a diameter below 100 nm (composed of isolated primary particles and small aggregates / agglomerates formed from a few primary particles): the number proportion of these particles varies from 0 to 44 % in the measurement range 14-360 nm depending on the types of powders and corrections of measurements.
Perceptual distance and the moon illusion.
Kaufman, Lloyd; Vassiliades, Vassias; Noble, Richard; Alexander, Robert; Kaufman, James; Edlund, Stefan
2007-01-01
The elevated moon usually appears smaller than the horizon moon of equal angular size. This is the moon illusion. Distance cues may enable the perceptual system to place the horizon moon at an effectively greater distance than the elevated moon, thus making it appear as larger. This explanation is related to the size-distance invariance hypothesis. However, the larger horizon moon is usually judged as closer than the smaller zenith moon. A bias to expect an apparently large object to be closer than a smaller object may account for this conflict. We designed experiments to determine if unbiased sensitivity to illusory differences in the size and distance of the moon (as measured by d') is consistent with SDIH. A moon above a 'terrain' was compared in both distance and size to an infinitely distant moon in empty space (the reduction moon). At a short distance the terrain moon was adjudged as both closer and smaller than the reduction moon. But these differences could not be detected at somewhat greater distances. At still greater distances the terrain moon was perceived as both more distant and larger than the reduction moon. The distances at which these transitions occurred were essentially the same for both distance and size discrimination tasks, thus supporting SDIH.
Infrared near-Earth-object survey modeling for observatories interior to the Earth's orbit
NASA Astrophysics Data System (ADS)
Buie, M.
2014-07-01
The search for and dynamical characterization of the near-Earth population of objects (NEOs) has been a busy topic for surveys for many years. Most of the work thus far has been from ground-based optical surveys such as the Catalina Sky Survey and LINEAR. These surveys have essentially reached a complete inventory of objects down to 1 km diameter and have shown that the known objects do not pose any significant impact threat. Smaller objects are correspondingly smaller threats but there are more of them and fewer of them have so far been discovered. The next generation of surveys is looking to extend their reach down to much smaller sizes. From an impact risk perspective, those objects as small as 30--40 m are still of interest (similar in size to the Tunguska bolide). Smaller objects than this are largely of interest from a space resource or in-situ analysis efforts. A recent mission concept promoted by the B612 Foundation and Ball Aerospace calls for an infrared survey telescope in a Venus-like orbit, known as the Sentinel Mission. This wide-field facility has been designed to complete the inventory down to a 140 m diameter while also providing substantial constraints on the NEO population down to a Tunguska-sized object. I have been working to develop a suite of tools to provide survey modeling for this class of survey telescope. The purpose of the tool is to uncover hidden complexities that govern mission design and operation while also working to quantitatively understand the orbit quality provided on its catalog of objects without additional followup assets. The baseline mission design calls for a 6.5 year survey lifetime. This survey model is a statistically based tool for establishing completeness as a function of object size and survey duration. Effects modeled include the ability to adjust the field-of-regard (includes all pointing restrictions), field-of-view, focal plane array fill factor, and the observatory orbit. Consequences tracked include time-tagged detection times from which orbit quality can be derived and efficiency by dynamical class. The dominant noise term in the simulations comes from the noise in the background flux caused by thermal emission from zodiacal dust. The model used is sufficient for the study of reasonably low-inclination spacecraft orbits such as are being considered. Results to date are based on the 2002 Bottke NEA orbit-distribution model. The system can work with any orbit-distribution model and with any size-frequency distribution. This tool also serves to quantify the amount of data that will also be collected on main-belt objects by simply testing against the known catalog of bodies. The orbit quality work clearly shows the benefit of a self-followup survey such as Sentinel. Most objects discovered will be seen in multiple observing epochs and the resulting orbits will preclude losing track of them for decades to come (or longer). All of the ephemeris calculations, including investigation of orbit determination quality, are done with the OpenOrb software package. The presentation for this meeting will be based on results of modeling the Sentinel Mission and other similar variants. The focus will be on evaluating the survey completion for different dynamical classes as well as for different sized objects. Within the fidelity of such statistically-based models, the planned Sentinel observatory is well capable of a huge step forward in the efforts to build a complete catalog of all objects that could pose future harm to planet Earth.
Zelinsky, G J
2001-02-01
Search, memory, and strategy constraints on change detection were analyzed in terms of oculomotor variables. Observers viewed a repeating sequence of three displays (Scene 1-->Mask-->Scene 2-->Mask...) and indicated the presence-absence of a changing object between Scenes 1 and 2. Scenes depicted real-world objects arranged on a surface. Manipulations included set size (one, three, or nine items) and the orientation of the changing objects (similar or different). Eye movements increased with the number of potentially changing objects in the scene, with this set size effect suggesting a relationship between change detection and search. A preferential fixation analysis determined that memory constraints are better described by the operation comparing the pre- and postchange objects than as a capacity limitation, and a scanpath analysis revealed a change detection strategy relying on the peripheral encoding and comparison of display items. These findings support a signal-in-noise interpretation of change detection in which the signal varies with the similarity of the changing objects and the noise is determined by the distractor objects and scene background.
How Do Object Size and Rigidity Affect Reaching and Grasping in Infants with Down Syndrome?
ERIC Educational Resources Information Center
de Campos, Ana Carolina; Francisco, Kelly Regina; Savelsbergh, Geert J. P.; Rocha, Nelci Adriana Cicuto Ferreira
2011-01-01
Reaching and grasping skills have been described to emerge from a dynamic interaction between intrinsic and extrinsic factors. The purpose of the present study was to investigate the interaction between such an intrinsic factor, Down syndrome, and extrinsic factors, such as different object properties. Seven infants with Down syndrome and seven…
Effects of Target Attributes on Children's Patterns of Referential Under- and Overspecification
ERIC Educational Resources Information Center
Charest, Monique; Johnston, Judith R.
2016-01-01
We examined the effects of object attributes on children's descriptive patterns in a referential communication task. Thirty preschoolers described object pairs that were selected by the experimenter. The targets were defined by shared size or colour, and differed on the non-target dimension in half of the trials. The children also completed a…
Stehman, S.V.; Wickham, J.D.; Wade, T.G.; Smith, J.H.
2008-01-01
The database design and diverse application of NLCD 2001 pose significant challenges for accuracy assessment because numerous objectives are of interest, including accuracy of land-cover, percent urban imperviousness, percent tree canopy, land-cover composition, and net change. A multi-support approach is needed because these objectives require spatial units of different sizes for reference data collection and analysis. Determining a sampling design that meets the full suite of desirable objectives for the NLCD 2001 accuracy assessment requires reconciling potentially conflicting design features that arise from targeting the different objectives. Multi-stage cluster sampling provides the general structure to achieve a multi-support assessment, and the flexibility to target different objectives at different stages of the design. We describe the implementation of two-stage cluster sampling for the initial phase of the NLCD 2001 assessment, and identify gaps in existing knowledge where research is needed to allow full implementation of a multi-objective, multi-support assessment. ?? 2008 American Society for Photogrammetry and Remote Sensing.
Touch Precision Modulates Visual Bias.
Misceo, Giovanni F; Jones, Maurice D
2018-01-01
The sensory precision hypothesis holds that different seen and felt cues about the size of an object resolve themselves in favor of the more reliable modality. To examine this precision hypothesis, 60 college students were asked to look at one size while manually exploring another unseen size either with their bare fingers or, to lessen the reliability of touch, with their fingers sleeved in rigid tubes. Afterwards, the participants estimated either the seen size or the felt size by finding a match from a visual display of various sizes. Results showed that the seen size biased the estimates of the felt size when the reliability of touch decreased. This finding supports the interaction between touch reliability and visual bias predicted by statistically optimal models of sensory integration.
Automatically Determining Scale Within Unstructured Point Clouds
NASA Astrophysics Data System (ADS)
Kadamen, Jayren; Sithole, George
2016-06-01
Three dimensional models obtained from imagery have an arbitrary scale and therefore have to be scaled. Automatically scaling these models requires the detection of objects in these models which can be computationally intensive. Real-time object detection may pose problems for applications such as indoor navigation. This investigation poses the idea that relational cues, specifically height ratios, within indoor environments may offer an easier means to obtain scales for models created using imagery. The investigation aimed to show two things, (a) that the size of objects, especially the height off ground is consistent within an environment, and (b) that based on this consistency, objects can be identified and their general size used to scale a model. To test the idea a hypothesis is first tested on a terrestrial lidar scan of an indoor environment. Later as a proof of concept the same test is applied to a model created using imagery. The most notable finding was that the detection of objects can be more readily done by studying the ratio between the dimensions of objects that have their dimensions defined by human physiology. For example the dimensions of desks and chairs are related to the height of an average person. In the test, the difference between generalised and actual dimensions of objects were assessed. A maximum difference of 3.96% (2.93cm) was observed from automated scaling. By analysing the ratio between the heights (distance from the floor) of the tops of objects in a room, identification was also achieved.
Gasilov, Sergei V; Coan, Paola
2012-09-01
Several x-ray phase contrast extraction algorithms use a set of images acquired along the rocking curve of a perfect flat analyzer crystal to study the internal structure of objects. By measuring the angular shift of the rocking curve peak, one can determine the local deflections of the x-ray beam propagated through a sample. Additionally, some objects determine a broadening of the crystal rocking curve, which can be explained in terms of multiple refraction of x rays by many subpixel-size inhomogeneities contained in the sample. This fact may allow us to differentiate between materials and features characterized by different refraction properties. In the present work we derive an expression for the beam broadening in the form of a linear integral of the quantity related to statistical properties of the dielectric susceptibility distribution function of the object.
Quantitative endoscopy: initial accuracy measurements.
Truitt, T O; Adelman, R A; Kelly, D H; Willging, J P
2000-02-01
The geometric optics of an endoscope can be used to determine the absolute size of an object in an endoscopic field without knowing the actual distance from the object. This study explores the accuracy of a technique that estimates absolute object size from endoscopic images. Quantitative endoscopy involves calibrating a rigid endoscope to produce size estimates from 2 images taken with a known traveled distance between the images. The heights of 12 samples, ranging in size from 0.78 to 11.80 mm, were estimated with this calibrated endoscope. Backup distances of 5 mm and 10 mm were used for comparison. The mean percent error for all estimated measurements when compared with the actual object sizes was 1.12%. The mean errors for 5-mm and 10-mm backup distances were 0.76% and 1.65%, respectively. The mean errors for objects <2 mm and > or =2 mm were 0.94% and 1.18%, respectively. Quantitative endoscopy estimates endoscopic image size to within 5% of the actual object size. This method remains promising for quantitatively evaluating object size from endoscopic images. It does not require knowledge of the absolute distance of the endoscope from the object, rather, only the distance traveled by the endoscope between images.
Effects of changes in size, speed and distance on the perception of curved 3D trajectories
Zhang, Junjun; Braunstein, Myron L.; Andersen, George J.
2012-01-01
Previous research on the perception of 3D object motion has considered time to collision, time to passage, collision detection and judgments of speed and direction of motion, but has not directly studied the perception of the overall shape of the motion path. We examined the perception of the magnitude of curvature and sign of curvature of the motion path for objects moving at eye level in a horizontal plane parallel to the line of sight. We considered two sources of information for the perception of motion trajectories: changes in angular size and changes in angular speed. Three experiments examined judgments of relative curvature for objects moving at different distances. At the closest distance studied, accuracy was high with size information alone but near chance with speed information alone. At the greatest distance, accuracy with size information alone decreased sharply but accuracy for displays with both size and speed information remained high. We found similar results in two experiments with judgments of sign of curvature. Accuracy was higher for displays with both size and speed information than with size information alone, even when the speed information was based on parallel projections and was not informative about sign of curvature. For both magnitude of curvature and sign of curvature judgments, information indicating that the trajectory was curved increased accuracy, even when this information was not directly relevant to the required judgment. PMID:23007204
Is Hefting to Perceive the Affordance for Throwing a Smart Perceptual Mechanism?
ERIC Educational Resources Information Center
Zhu, Qin; Bingham, Geoffrey P.
2008-01-01
G. P. Bingham, R. C. Schmidt, and L. D. Rosenblum (1989) found that, by hefting objects of different sizes and weights, people could choose the optimal weight in each size for throwing to a maximum distance. In Experiment 1, the authors replicated this result. G. P. Bingham et al. hypothesized that hefting is a smart mechanism that allows objects…
ERIC Educational Resources Information Center
Cicchetti, Domenic V.; Koenig, Kathy; Klin, Ami; Volkmar, Fred R.; Paul, Rhea; Sparrow, Sara
2011-01-01
The objectives of this report are: (a) to trace the theoretical roots of the concept clinical significance that derives from Bayesian thinking, Marginal Utility/Diminishing Returns in Economics, and the "just noticeable difference", in Psychophysics. These concepts then translated into: Effect Size (ES), strength of agreement, clinical…
Effect of tire size on skidder productivity
Richard W. Brinkcr; John F. Klepac; Bryce J. Stokes; Joe D. Roberson
1996-01-01
During the Spring of 1996 a collaborative effort among Mead Coated Board. the Auburn University School of Forestry. and the Southern Research Station was initiated to evaluate skidder production performance as a function of tire size and soil condition (i.e. wet and dry season)_ The objective of the study was to determine production and cost differences among 28L-26....
ERIC Educational Resources Information Center
Al Kuwaiti, Ahmed; AlQuraan, Mahmoud; Subbarayalu, Arun Vijay
2016-01-01
Objective: This study aims to investigate the interaction between response rate and class size and its effects on students' evaluation of instructors and the courses offered at a higher education Institution in Saudi Arabia. Study Design: A retrospective study design was chosen. Methods: One thousand four hundred and forty four different courses…
Effect of tire size on skidder productivity
Richard W. Brinker; John F. Klepac; Bryce J. Stokes; Joe D. Roberson
1996-01-01
During the spring of 1996 a collaborative effort among Mead Coated Board, the Auburn University School of Forestry, and the Southern Research Station was initiated to evaluate skidder production performance as a function of tire size and soil condition (i.e., wet and dry season). The objective of the study was to determine production and cost differences among 28L-26,...
Structured Light-Based 3D Reconstruction System for Plants.
Nguyen, Thuy Tuong; Slaughter, David C; Max, Nelson; Maloof, Julin N; Sinha, Neelima
2015-07-29
Camera-based 3D reconstruction of physical objects is one of the most popular computer vision trends in recent years. Many systems have been built to model different real-world subjects, but there is lack of a completely robust system for plants. This paper presents a full 3D reconstruction system that incorporates both hardware structures (including the proposed structured light system to enhance textures on object surfaces) and software algorithms (including the proposed 3D point cloud registration and plant feature measurement). This paper demonstrates the ability to produce 3D models of whole plants created from multiple pairs of stereo images taken at different viewing angles, without the need to destructively cut away any parts of a plant. The ability to accurately predict phenotyping features, such as the number of leaves, plant height, leaf size and internode distances, is also demonstrated. Experimental results show that, for plants having a range of leaf sizes and a distance between leaves appropriate for the hardware design, the algorithms successfully predict phenotyping features in the target crops, with a recall of 0.97 and a precision of 0.89 for leaf detection and less than a 13-mm error for plant size, leaf size and internode distance.
NASA Astrophysics Data System (ADS)
Koshti, Ajay M.
2018-03-01
Like other NDE methods, eddy current surface crack detectability is determined using probability of detection (POD) demonstration. The POD demonstration involves eddy current testing of surface crack specimens with known crack sizes. Reliably detectable flaw size, denoted by, a90/95 is determined by statistical analysis of POD test data. The surface crack specimens shall be made from a similar material with electrical conductivity close to the part conductivity. A calibration standard with electro-discharged machined (EDM) notches is typically used in eddy current testing for surface crack detection. The calibration standard conductivity shall be within +/- 15% of the part conductivity. This condition is also applicable to the POD demonstration crack set. Here, a case is considered, where conductivity of the crack specimens available for POD testing differs by more than 15% from that of the part to be inspected. Therefore, a direct POD demonstration of reliably detectable flaw size is not applicable. Additional testing is necessary to use the demonstrated POD test data. An approach to estimate the reliably detectable flaw size in eddy current testing for part made from material A using POD crack specimens made from material B with different conductivity is provided. The approach uses additional test data obtained on EDM notch specimens made from materials A and B. EDM notch test data from the two materials is used to create a transfer function between the demonstrated a90/95 size on crack specimens made of material B and the estimated a90/95 size for part made of material A. Two methods are given. For method A, a90/95 crack size for material B is given and POD data is available. Objective of method A is to determine a90/95 crack size for material A using the same relative decision threshold that was used for material B. For method B, target crack size a90/95 for material A is known. Objective is to determine decision threshold for inspecting material A.
Wang, Jun; Kang, Tony; Arepalli, Chesnal; Barrett, Sarah; O'Connell, Tim; Louis, Luck; Nicolaou, Savvakis; McLaughlin, Patrick
2015-06-01
The objective of this study is to establish the effect of third-generation integrated circuit (IC) CT detector on objective image quality in full- and half-dose non-contrast CT of the urinary tract. 51 consecutive patients with acute renal colic underwent non-contrast CT of the urinary tract using a 128-slice dual-source CT before (n = 24) and after (n = 27) the installation of third-generation IC detectors. Half-dose images were generated using projections from detector A using the dual-source RAW data. Objective image noise in the liver, spleen, right renal cortex, and right psoas muscle was compared between DC and IC cohorts for full-dose and half-dose images reconstructed with FBP and IR algorithms using 1 cm(2) regions of interest. Presence and size of obstructing ureteric calculi were also compared for full-dose and half-dose reconstructions using DC and IC detectors. No statistical difference in age and lateral body size was found between patients in the IC and DC cohorts. Radiation dose, as measured by size-specific dose estimates, did not differ significantly either between the two cohorts (10.02 ± 4.54 mGy IC vs. 12.28 ± 7.03 mGy DC). At full dose, objective image noise was not significantly lower in the IC cohort as compared to the DC cohort for the liver, spleen, and right psoas muscle. At half dose, objective image noise was lower in the IC cohort as compared to DC cohort at the liver (21.32 IC vs. 24.99 DC, 14.7% decrease, p < 0.001), spleen (19.33 IC vs. 20.83 DC, 7.20% decrease, p = 0.02), and right renal cortex (20.28 IC vs. 22.98 DC, 11.7% decrease, p = 0.005). Mean obstructing ureteric calculi size was not significantly different when comparison was made between full-dose and half-dose images, regardless of detector type (p > 0.05 for all comparisons). Third-generation IC detectors result in lower objective image noise at full- and half-radiation dose levels as compared with traditional DC detectors. The magnitude of noise reduction was greater at half-radiation dose indicating that the benefits of using novel IC detectors are greater in low and ultra-low-dose CT imaging.
A real-world size organization of object responses in occipito-temporal cortex
Konkle, Talia; Oliva, Aude
2012-01-01
SUMMARY While there are selective regions of occipito-temporal cortex that respond to faces, letters, and bodies, the large-scale neural organization of most object categories remains unknown. Here we find that object representations can be differentiated along the ventral temporal cortex by their real-world size. In a functional neuroimaging experiment, observers were shown pictures of big and small real-world objects (e.g. table, bathtub; paperclip, cup), presented at the same retinal size. We observed a consistent medial-to-lateral organization of big and small object preferences in the ventral temporal cortex, mirrored along the lateral surface. Regions in the lateral-occipital, infero-temporal, and parahippocampal cortices showed strong peaks of differential real-world size selectivity, and maintained these preferences over changes in retinal size and in mental imagery. These data demonstrate that the real-world size of objects can provide insight into the spatial topography of object representation. PMID:22726840
Hydrodynamic resistance and mobility of deformable objects in microfluidic channels
Sajeesh, P.; Doble, M.; Sen, A. K.
2014-01-01
This work reports experimental and theoretical studies of hydrodynamic behaviour of deformable objects such as droplets and cells in a microchannel. Effects of mechanical properties including size and viscosity of these objects on their deformability, mobility, and induced hydrodynamic resistance are investigated. The experimental results revealed that the deformability of droplets, which is quantified in terms of deformability index (D.I.), depends on the droplet-to-channel size ratio ρ and droplet-to-medium viscosity ratio λ. Using a large set of experimental data, for the first time, we provide a mathematical formula that correlates induced hydrodynamic resistance of a single droplet ΔRd with the droplet size ρ and viscosity λ. A simple theoretical model is developed to obtain closed form expressions for droplet mobility ϕ and ΔRd. The predictions of the theoretical model successfully confront the experimental results in terms of the droplet mobility ϕ and induced hydrodynamic resistance ΔRd. Numerical simulations are carried out using volume-of-fluid model to predict droplet generation and deformation of droplets of different size ratio ρ and viscosity ratio λ, which compare well with that obtained from the experiments. In a novel effort, we performed experiments to measure the bulk induced hydrodynamic resistance ΔR of different biological cells (yeast, L6, and HEK 293). The results reveal that the bulk induced hydrodynamic resistance ΔR is related to the cell concentration and apparent viscosity of the cells. PMID:25538806
Perceived Average Orientation Reflects Effective Gist of the Surface.
Cha, Oakyoon; Chong, Sang Chul
2018-03-01
The human ability to represent ensemble visual information, such as average orientation and size, has been suggested as the foundation of gist perception. To effectively summarize different groups of objects into the gist of a scene, observers should form ensembles separately for different groups, even when objects have similar visual features across groups. We hypothesized that the visual system utilizes perceptual groups characterized by spatial configuration and represents separate ensembles for different groups. Therefore, participants could not integrate ensembles of different perceptual groups on a task basis. We asked participants to determine the average orientation of visual elements comprising a surface with a contour situated inside. Although participants were asked to estimate the average orientation of all the elements, they ignored orientation signals embedded in the contour. This constraint may help the visual system to keep the visual features of occluding objects separate from those of the occluded objects.
Bøcher, Peder Klith; McCloy, Keith R
2006-02-01
In this investigation, the characteristics of the average local variance (ALV) function is investigated through the acquisition of images at different spatial resolutions of constructed scenes of regular patterns of black and white squares. It is shown that the ALV plot consistently peaks at a spatial resolution in which the pixels has a size corresponding to half the distance between scene objects, and that, under very specific conditions, it also peaks at a spatial resolution in which the pixel size corresponds to the whole distance between scene objects. It is argued that the peak at object distance when present is an expression of the Nyquist sample rate. The presence of this peak is, hence, shown to be a function of the matching between the phase of the scene pattern and the phase of the sample grid, i.e., the image. When these phases match, a clear and distinct peak is produced on the ALV plot. The fact that the peak at half the distance consistently occurs in the ALV plot is linked to the circumstance that the sampling interval (distance between pixels) and the extent of the sampling unit (size of pixels) are equal. Hence, at twice the Nyquist sampling rate, each fundamental period of the pattern is covered by four pixels; therefore, at least one pixel is always completely embedded within one pattern element, regardless of sample scene phase. If the objects in the scene are scattered with a distance larger than their extent, the peak will be related to the size by a factor larger than 1/2. This is suggested to be the explanation to the results presented by others that the ALV plot is related to scene-object size by a factor of 1/2-3/4.
Ground-plane influences on size estimation in early visual processing.
Champion, Rebecca A; Warren, Paul A
2010-07-21
Ground-planes have an important influence on the perception of 3D space (Gibson, 1950) and it has been shown that the assumption that a ground-plane is present in the scene plays a role in the perception of object distance (Bruno & Cutting, 1988). Here, we investigate whether this influence is exerted at an early stage of processing, to affect the rapid estimation of 3D size. Participants performed a visual search task in which they searched for a target object that was larger or smaller than distracter objects. Objects were presented against a background that contained either a frontoparallel or slanted 3D surface, defined by texture gradient cues. We measured the effect on search performance of target location within the scene (near vs. far) and how this was influenced by scene orientation (which, e.g., might be consistent with a ground or ceiling plane, etc.). In addition, we investigated how scene orientation interacted with texture gradient information (indicating surface slant), to determine how these separate cues to scene layout were combined. We found that the difference in target detection performance between targets at the front and rear of the simulated scene was maximal when the scene was consistent with a ground-plane - consistent with the use of an elevation cue to object distance. In addition, we found a significant increase in the size of this effect when texture gradient information (indicating surface slant) was present, but no interaction between texture gradient and scene orientation information. We conclude that scene orientation plays an important role in the estimation of 3D size at an early stage of processing, and suggest that elevation information is linearly combined with texture gradient information for the rapid estimation of 3D size. Copyright 2010 Elsevier Ltd. All rights reserved.
No Effect of Featural Attention on Body Size Aftereffects
Stephen, Ian D.; Bickersteth, Chloe; Mond, Jonathan; Stevenson, Richard J.; Brooks, Kevin R.
2016-01-01
Prolonged exposure to images of narrow bodies has been shown to induce a perceptual aftereffect, such that observers’ point of subjective normality (PSN) for bodies shifts toward narrower bodies. The converse effect is shown for adaptation to wide bodies. In low-level stimuli, object attention (attention directed to the object) and spatial attention (attention directed to the location of the object) have been shown to increase the magnitude of visual aftereffects, while object-based attention enhances the adaptation effect in faces. It is not known whether featural attention (attention directed to a specific aspect of the object) affects the magnitude of adaptation effects in body stimuli. Here, we manipulate the attention of Caucasian observers to different featural information in body images, by asking them to rate the fatness or sex typicality of male and female bodies manipulated to appear fatter or thinner than average. PSNs for body fatness were taken at baseline and after adaptation, and a change in PSN (ΔPSN) was calculated. A body size adaptation effect was found, with observers who viewed fat bodies showing an increased PSN, and those exposed to thin bodies showing a reduced PSN. However, manipulations of featural attention to body fatness or sex typicality produced equivalent results, suggesting that featural attention may not affect the strength of the body size aftereffect. PMID:27597835
No Effect of Featural Attention on Body Size Aftereffects.
Stephen, Ian D; Bickersteth, Chloe; Mond, Jonathan; Stevenson, Richard J; Brooks, Kevin R
2016-01-01
Prolonged exposure to images of narrow bodies has been shown to induce a perceptual aftereffect, such that observers' point of subjective normality (PSN) for bodies shifts toward narrower bodies. The converse effect is shown for adaptation to wide bodies. In low-level stimuli, object attention (attention directed to the object) and spatial attention (attention directed to the location of the object) have been shown to increase the magnitude of visual aftereffects, while object-based attention enhances the adaptation effect in faces. It is not known whether featural attention (attention directed to a specific aspect of the object) affects the magnitude of adaptation effects in body stimuli. Here, we manipulate the attention of Caucasian observers to different featural information in body images, by asking them to rate the fatness or sex typicality of male and female bodies manipulated to appear fatter or thinner than average. PSNs for body fatness were taken at baseline and after adaptation, and a change in PSN (ΔPSN) was calculated. A body size adaptation effect was found, with observers who viewed fat bodies showing an increased PSN, and those exposed to thin bodies showing a reduced PSN. However, manipulations of featural attention to body fatness or sex typicality produced equivalent results, suggesting that featural attention may not affect the strength of the body size aftereffect.
3D printed glass: surface finish and bulk properties as a function of the printing process
NASA Astrophysics Data System (ADS)
Klein, Susanne; Avery, Michael P.; Richardson, Robert; Bartlett, Paul; Frei, Regina; Simske, Steven
2015-03-01
It is impossible to print glass directly from a melt, layer by layer. Glass is not only very sensitive to temperature gradients between different layers but also to the cooling process. To achieve a glass state the melt, has to be cooled rapidly to avoid crystallization of the material and then annealed to remove cooling induced stress. In 3D-printing of glass the objects are shaped at room temperature and then fired. The material properties of the final objects are crucially dependent on the frit size of the glass powder used during shaping, the chemical formula of the binder and the firing procedure. For frit sizes below 250 μm, we seem to find a constant volume of pores of less than 5%. Decreasing frit size leads to an increase in the number of pores which then leads to an increase of opacity. The two different binders, 2- hydroxyethyl cellulose and carboxymethylcellulose sodium salt, generate very different porosities. The porosity of samples with 2-hydroxyethyl cellulose is similar to frit-only samples, whereas carboxymethylcellulose sodium salt creates a glass foam. The surface finish is determined by the material the glass comes into contact with during firing.
Ibrahim, Mohd Rasdan; Katman, Herda Yati; Karim, Mohamed Rehan; Koting, Suhana; Mashaan, Nuha S.
2014-01-01
The main objective of this paper is to investigate the relations of rubber size, rubber content, and binder content in determination of optimum binder content for open graded friction course (OGFC). Mix gradation type B as specified in Specification for Porous Asphalt produced by the Road Engineering Association of Malaysia (REAM) was used in this study. Marshall specimens were prepared with four different sizes of rubber, namely, 20 mesh size [0.841 mm], 40 mesh [0.42 mm], 80 mesh [0.177 mm], and 100 mesh [0.149 mm] with different concentrations of rubberised bitumen (4%, 8%, and 12%) and different percentages of binder content (4%–7%). The appropriate optimum binder content is then selected according to the results of the air voids, binder draindown, and abrasion loss test. Test results found that crumb rubber particle size can affect the optimum binder content for OGFC. PMID:24574875
Animacy and real-world size shape object representations in the human medial temporal lobes.
Blumenthal, Anna; Stojanoski, Bobby; Martin, Chris B; Cusack, Rhodri; Köhler, Stefan
2018-06-26
Identifying what an object is, and whether an object has been encountered before, is a crucial aspect of human behavior. Despite this importance, we do not yet have a complete understanding of the neural basis of these abilities. Investigations into the neural organization of human object representations have revealed category specific organization in the ventral visual stream in perceptual tasks. Interestingly, these categories fall within broader domains of organization, with reported distinctions between animate, inanimate large, and inanimate small objects. While there is some evidence for category specific effects in the medial temporal lobe (MTL), in particular in perirhinal and parahippocampal cortex, it is currently unclear whether domain level organization is also present across these structures. To this end, we used fMRI with a continuous recognition memory task. Stimuli were images of objects from several different categories, which were either animate or inanimate, or large or small within the inanimate domain. We employed representational similarity analysis (RSA) to test the hypothesis that object-evoked responses in MTL structures during recognition-memory judgments also show evidence for domain-level organization along both dimensions. Our data support this hypothesis. Specifically, object representations were shaped by either animacy, real-world size, or both, in perirhinal and parahippocampal cortex, and the hippocampus. While sensitivity to these dimensions differed across structures when probed individually, hinting at interesting links to functional differentiation, similarities in organization across MTL structures were more prominent overall. These results argue for continuity in the organization of object representations in the ventral visual stream and the MTL. © 2018 Wiley Periodicals, Inc.
Cross-cultural variation of memory colors of familiar objects.
Smet, Kevin A G; Lin, Yandan; Nagy, Balázs V; Németh, Zoltan; Duque-Chica, Gloria L; Quintero, Jesús M; Chen, Hung-Shing; Luo, Ronnier M; Safi, Mahdi; Hanselaer, Peter
2014-12-29
The effect of cross-regional or cross-cultural differences on color appearance ratings and memory colors of familiar objects was investigated in seven different countries/regions - Belgium, Hungary, Brazil, Colombia, Taiwan, China and Iran. In each region the familiar objects were presented on a calibrated monitor in over 100 different colors to a test panel of observers that were asked to rate the similarity of the presented object color with respect to what they thought the object looks like in reality (memory color). For each object and region the mean observer ratings were modeled by a bivariate Gaussian function. A statistical analysis showed significant (p < 0.001) differences between the region average observers and the global average observer obtained by pooling the data from all regions. However, the effect size of geographical region or culture was found to be small. In fact, the differences between the region average observers and the global average observer were found to of the same magnitude or smaller than the typical within region inter-observer variability. Thus, although statistical differences in color appearance ratings and memory between regions were found, regional impact is not likely to be of practical importance.
Operator Localization of Virtual Objects
NASA Technical Reports Server (NTRS)
Ellis, Stephen R.; Menges, Brian M.; Null, Cynthia H. (Technical Monitor)
1998-01-01
Errors in the localization of nearby virtual objects presented via see-through, helmet mounted displays are examined as a function of viewing conditions and scene content. Monocular, biocular or stereoscopic presentation of the virtual objects, accommodation (required focus), subjects'age, and the position of physical surfaces are examined. Nearby physical surfaces are found to introduce localization errors that differ depending upon the other experimental factors. The apparent physical size and transparency of the virtual objects and physical surfaces respectively are also influenced by their relative position when superimposed. Design implications are discussed.
Gentilucci, Maurizio; Campione, Giovanna Cristina; Dalla Volta, Riccardo; Bernardis, Paolo
2009-12-01
Does the mirror system affect the control of speech? This issue was addressed in behavioral and Transcranial Magnetic Stimulation (TMS) experiments. In behavioral experiment 1, participants pronounced the syllable /da/ while observing (1) a hand grasping large and small objects with power and precision grasps, respectively, (2) a foot interacting with large and small objects and (3) differently sized objects presented alone. Voice formant 1 was higher when observing power as compared to precision grasp, whereas it remained unaffected by observation of the different types of foot interaction and objects alone. In TMS experiment 2, we stimulated hand motor cortex, while participants observed the two types of grasp. Motor Evoked Potentials (MEPs) of hand muscles active during the two types of grasp were greater when observing power than precision grasp. In experiments 3-5, TMS was applied to tongue motor cortex of participants silently pronouncing the syllable /da/ and simultaneously observing power and precision grasps, pantomimes of the two types of grasps, and differently sized objects presented alone. Tongue MEPs were greater when observing power than precision grasp either executed or pantomimed. Finally, in TMS experiment 6, the observation of foot interaction with large and small objects did not modulate tongue MEPs. We hypothesized that grasp observation activated motor commands to the mouth as well as to the hand that were congruent with the hand kinematics implemented in the observed type of grasp. The commands to the mouth selectively affected postures of phonation organs and consequently basic features of phonological units.
Less Is More--Mathematical Manipulatives in Early Childhood Education
ERIC Educational Resources Information Center
Björklund, Camilla
2014-01-01
This article is a discussion drawing on a learning study with a teacher working with one- and two-year-olds. The focal interest is a scrutiny of the use of manipulative objects, emanating from observations of a teacher's and children's use of, and responses to the use of, different objects. The concept of size and the notions "large" and…
Large-Scale Diffraction Patterns from Circular Objects
ERIC Educational Resources Information Center
Rinard, Phillip M.
1976-01-01
Investigates quantitatively the diffractions of light by a U.S. penny and an aperture of the same size. Differences noted between the theory and measurements are discussed, with probable causes indicated. (Author/CP)
A novel cluster-tube self-adaptive robot hand.
Fu, Hong; Yang, Haokun; Song, Weishu; Zhang, Wenzeng
2017-01-01
This paper proposes a novel cluster-tube self-adaptive robot hand (CTSA Hand). The CTSA Hand consists of a base, a motor, a transmission mechanism, multiple elastic tendons, and a group of sliding-tube assemblies. Each sliding-tube assembly is composed of a sliding tube, a guide rod, two springs and a hinge. When the hand grasping an object, the object pushes some sliding tubes to different positions according to the surface shape of the object, the motor pulls the tendons tight to cluster tubes. The CTSA Hand can realize self-adaptive grasping of objects of different sizes and shapes. The CTSA Hand can grasp multiple objects simultaneously because the grasping of the hand acts as many grippers in different directions and heights. The grasping forces of the hand are adjusted by a closed-loop control system with potentiometer. Experimental results show that the CTSA Hand has the features of highly self-adaption and large grasping forces when grasping various objects.
It’s Out of My Hands! Grasping Capacity May Not Influence Perceived Object Size
2017-01-01
Linkenauger, Witt, and Proffitt (2011) found that the perceived size of graspable objects was scaled by perceived grasping capacity. However, it is possible that this effect occurred because object size was estimated on the same trial as grasping capacity. This may have led to a conflation of estimates of perceived action capacity and spatial properties. In 5 experiments, we tested Linkenauger et al.’s claim that right-handed observers overestimate the grasping capacity of their right hand relative to their left hand, and that this, in turn, leads them to underestimate the size of objects to-be-grasped in their right hand relative to their left hand. We replicated the finding that right handers overestimate the size and grasping capacity of their right hand relative to their left hand. However, when estimates of object size and grasping capacity were made in separate tasks, objects grasped in the right hand were not underestimated relative to those grasped in the left hand. Further, when grasping capacity was physically restricted, observers appropriately recalibrated their perception of their maximum grasp but estimates of object size were unaffected. Our results suggest that changes in action capacity may not influence perceived object size if sources of conflation are controlled for. PMID:28191987
Kirwan, L; Walsh, M C; Brennan, L; Gibney, E R; Drevon, C A; Daniel, H; Lovegrove, J A; Manios, Y; Martínez, J A; Saris, W H M; Traczyk, I; Mathers, J C; Gibney, M
2016-05-01
There are no standardised serving/portion sizes defined for foods consumed in the European Union (EU). Typical serving sizes can deviate significantly from the 100 g/100 ml labelling specification required by the EU legislation. Where the nutritional value of a portion is specified, the portion size is determined by the manufacturers. Our objective was to investigate the potential for standardising portion sizes for specific foods, thereby ensuring complementarity across countries. We compared portion size for 156 food items measured using a food frequency questionnaire across the seven countries participating in the Food4me study. The probability of consuming a food and the frequency of consumption differed across countries for 93% and 58% of the foods, respectively. However, the individual country mean portion size differed from the average across countries in only 16% of comparisons. Thus, although dietary choices vary markedly across countries, there is much less variation in portion sizes. Our results highlight the potential for standardisation of portion sizes on nutrition labels in the EU.
Influence of container size on Wyoming big sagebrush seedling morphology and cold hardiness
Kayla R. Herriman; Anthony S. Davis; R. Kasten Dumroese
2009-01-01
Wyoming big sagebrush (Artemisia tridentata) is a key component of sagebrush steppe ecosystems and is a dominant shrub throughout the western United States. Our objective was to identify the effect of container size on plant morphology of Wyoming big sagebrush. We used three different stocktypes (45/340 ml [20 in3], 60/250 ml [15 in3], 112/105 ml [6....
Multi-objects recognition for distributed intelligent sensor networks
NASA Astrophysics Data System (ADS)
He, Haibo; Chen, Sheng; Cao, Yuan; Desai, Sachi; Hohil, Myron E.
2008-04-01
This paper proposes an innovative approach for multi-objects recognition for homeland security and defense based intelligent sensor networks. Unlike the conventional way of information analysis, data mining in such networks is typically characterized with high information ambiguity/uncertainty, data redundancy, high dimensionality and real-time constrains. Furthermore, since a typical military based network normally includes multiple mobile sensor platforms, ground forces, fortified tanks, combat flights, and other resources, it is critical to develop intelligent data mining approaches to fuse different information resources to understand dynamic environments, to support decision making processes, and finally to achieve the goals. This paper aims to address these issues with a focus on multi-objects recognition. Instead of classifying a single object as in the traditional image classification problems, the proposed method can automatically learn multiple objectives simultaneously. Image segmentation techniques are used to identify the interesting regions in the field, which correspond to multiple objects such as soldiers or tanks. Since different objects will come with different feature sizes, we propose a feature scaling method to represent each object in the same number of dimensions. This is achieved by linear/nonlinear scaling and sampling techniques. Finally, support vector machine (SVM) based learning algorithms are developed to learn and build the associations for different objects, and such knowledge will be adaptively accumulated for objects recognition in the testing stage. We test the effectiveness of proposed method in different simulated military environments.
Poláček, Miroslav; Griggio, Matteo; Bartíková, Michaela; Hoi, Herbert
2013-01-01
Higher interclutch colour variation can evolve under the pressure of brood parasitism to increase the detection of parasitic eggs. Nest sanitation could be a prerequisite for the evolution of anti-parasite defence in terms of egg ejection. In this respect, we used nest sanitation behaviour as a tool to identify: i) motivation and its underlying function and, ii) which features provoke ejection behaviour. Therefore, we experimentally tested whether size, colour or shape may influence ejection behaviour using artificial flat objects. We found a high interclutch variation in egg colouration and egg size in our tree sparrow (Passer montanus) population. Using colour and size we were in fact able to predict clutch affiliation for each egg. Our experiments further revealed the existence of direct anti-parasite behaviours and birds are able to recognise conspecific eggs, since only experimentally-deposited eggs have been removed. Moreover, experiments with different objects revealed that the motivation of tree sparrows to remove experimental objects from their nests was highest during egg laying for objects of varying size, most likely because of parasitism risk at this breeding stage. In contrary, motivation to remove white objects and objects with edges was higher during incubation stage as behavioural patterns connected to hatching started to emerge. The fact that rejection rate of our flat objects was higher than real egg ejection, suggests that egg ejection in tree sparrows and probably more general in small passerines, to be limited by elevated costs to eject eggs with their beaks. The presence of anti-parasite behaviour supports our suggestion that brood parasitism causes variation in egg features, as we have found that tree sparrows can recognise and reject conspecific eggs in their clutch. In conclusion, in tree sparrows it seems that nest sanitation plays a key role in the evolution of the removal of parasitic eggs. PMID:24223165
Poláček, Miroslav; Griggio, Matteo; Bartíková, Michaela; Hoi, Herbert
2013-01-01
Higher interclutch colour variation can evolve under the pressure of brood parasitism to increase the detection of parasitic eggs. Nest sanitation could be a prerequisite for the evolution of anti-parasite defence in terms of egg ejection. In this respect, we used nest sanitation behaviour as a tool to identify: i) motivation and its underlying function and, ii) which features provoke ejection behaviour. Therefore, we experimentally tested whether size, colour or shape may influence ejection behaviour using artificial flat objects. We found a high interclutch variation in egg colouration and egg size in our tree sparrow (Passer montanus) population. Using colour and size we were in fact able to predict clutch affiliation for each egg. Our experiments further revealed the existence of direct anti-parasite behaviours and birds are able to recognise conspecific eggs, since only experimentally-deposited eggs have been removed. Moreover, experiments with different objects revealed that the motivation of tree sparrows to remove experimental objects from their nests was highest during egg laying for objects of varying size, most likely because of parasitism risk at this breeding stage. In contrary, motivation to remove white objects and objects with edges was higher during incubation stage as behavioural patterns connected to hatching started to emerge. The fact that rejection rate of our flat objects was higher than real egg ejection, suggests that egg ejection in tree sparrows and probably more general in small passerines, to be limited by elevated costs to eject eggs with their beaks. The presence of anti-parasite behaviour supports our suggestion that brood parasitism causes variation in egg features, as we have found that tree sparrows can recognise and reject conspecific eggs in their clutch. In conclusion, in tree sparrows it seems that nest sanitation plays a key role in the evolution of the removal of parasitic eggs.
NASA Astrophysics Data System (ADS)
Ahmed, Naveed; Alahmari, Abdulrahman M.; Darwish, Saied; Naveed, Madiha
2016-12-01
Micro-channels are considered as the integral part of several engineering devices such as micro-channel heat exchangers, micro-coolers, micro-pulsating heat pipes and micro-channels used in gas turbine blades for aerospace applications. In such applications, a fluid flow is required to pass through certain micro-passages such as micro-grooves and micro-channels. The fluid flow characteristics (flow rate, turbulence, pressure drop and fluid dynamics) are mainly established based on the size and accuracy of micro-passages. Variations (oversizing and undersizing) in micro-passage's geometry directly affect the fluid flow characteristics. In this study, the micro-channels of several sizes are fabricated in well-known aerospace nickel alloy (Inconel 718) through laser beam micro-milling. The variations in geometrical characteristics of different-sized micro-channels are studied under the influences of different parameters of Nd:YAG laser. In order to have a minimum variation in the machined geometries of each size of micro-channel, the multi-objective optimization of laser parameters has been carried out utilizing the response surface methodology approach. The objective was set to achieve the targeted top widths and depths of micro-channels with minimum degree of taperness associated with the micro-channel's sidewalls. The optimized sets of laser parameters proposed for each size of micro-channel can be used to fabricate the micro-channels in Inconel 718 with minimum amount of geometrical variations.
Pictorial depth probed through relative sizes
Wagemans, Johan; van Doorn, Andrea J; Koenderink, Jan J
2011-01-01
In the physical environment familiar size is an effective depth cue because the distance from the eye to an object equals the ratio of its physical size to its angular extent in the visual field. Such simple geometrical relations do not apply to pictorial space, since the eye itself is not in pictorial space, and consequently the notion “distance from the eye” is meaningless. Nevertheless, relative size in the picture plane is often used by visual artists to suggest depth differences. The depth domain has no natural origin, nor a natural unit; thus only ratios of depth differences could have an invariant significance. We investigate whether the pictorial relative size cue yields coherent depth structures in pictorial spaces. Specifically, we measure the depth differences for all pairs of points in a 20-point configuration in pictorial space, and we account for these observations through 19 independent parameters (the depths of the points modulo an arbitrary offset), with no meaningful residuals. We discuss a simple formal framework that allows one to handle individual differences. We also compare the depth scale obtained by way of this method with depth scales obtained in totally different ways, finding generally good agreement. PMID:23145258
Finding the Best Logo for Your Students.
ERIC Educational Resources Information Center
Harvey, Brian
1987-01-01
Variations among different versions of Logo are discussed in terms of special hardware needed, size and speed, bugs and misfeatures, and syntax. LogoWriter and Object Logo are also described. A comparison chart is included. (MNS)
Vasin, A L
2003-01-01
Appropriateness of representation of a biological object surface as an equipotential surface has been proved for conditions of a quasistatic exposure to EMF of frequencies lower than 1 MHz. The conditions, at which a self capacitance of a biological object is its basic electrical parameter, have been considered. A factor of animal-to-human approximation of low-frequency EMF exposure conditions was estimated on the basis of equal dose loading in biological objects of different geometric sizes.
Josef, Noam; Berenshtein, Igal; Rousseau, Meghan; Scata, Gabriella; Fiorito, Graziano; Shashar, Nadav
2017-01-01
Camouflage is common throughout the phylogenetic tree and is largely used to minimize detection by predator or prey. Cephalopods, and in particular Sepia officinalis cuttlefish, are common models for camouflage studies. Predator avoidance behavior is particularly important in this group of soft-bodied animals that lack significant physical defenses. While previous studies have suggested that immobile cephalopods selectively camouflage to objects in their immediate surroundings, the camouflage characteristics of cuttlefish during movement are largely unknown. In a heterogenic environment, the visual background and substrate feature changes quickly as the animal swim across it, wherein substrate patch is a distinctive and high contrast patch of substrate in the animal's trajectory. In the current study, we examine the effect of substrate patch size on cuttlefish camouflage, and specifically the minimal size of an object for eliciting intensity matching response while moving. Our results indicated that substrate patch size has a positive effect on animal's reflectance change, and that the threshold patch size resulting in camouflage response falls between 10 and 19 cm (width). These observations suggest that the animal's length (7.2–12.3 cm mantle length in our case) serves as a possible threshold filter below which objects are considered irrelevant for camouflage, reducing the frequency of reflectance changes—which may lead to detection. Accordingly, we have constructed a computational model capturing the main features of the observed camouflaging behavior, provided for cephalopod camouflage during movement. PMID:28144221
Josef, Noam; Berenshtein, Igal; Rousseau, Meghan; Scata, Gabriella; Fiorito, Graziano; Shashar, Nadav
2016-01-01
Camouflage is common throughout the phylogenetic tree and is largely used to minimize detection by predator or prey. Cephalopods, and in particular Sepia officinalis cuttlefish, are common models for camouflage studies. Predator avoidance behavior is particularly important in this group of soft-bodied animals that lack significant physical defenses. While previous studies have suggested that immobile cephalopods selectively camouflage to objects in their immediate surroundings, the camouflage characteristics of cuttlefish during movement are largely unknown. In a heterogenic environment, the visual background and substrate feature changes quickly as the animal swim across it, wherein substrate patch is a distinctive and high contrast patch of substrate in the animal's trajectory. In the current study, we examine the effect of substrate patch size on cuttlefish camouflage, and specifically the minimal size of an object for eliciting intensity matching response while moving. Our results indicated that substrate patch size has a positive effect on animal's reflectance change, and that the threshold patch size resulting in camouflage response falls between 10 and 19 cm (width). These observations suggest that the animal's length (7.2-12.3 cm mantle length in our case) serves as a possible threshold filter below which objects are considered irrelevant for camouflage, reducing the frequency of reflectance changes-which may lead to detection. Accordingly, we have constructed a computational model capturing the main features of the observed camouflaging behavior, provided for cephalopod camouflage during movement.
Two-tier tissue decomposition for histopathological image representation and classification.
Gultekin, Tunc; Koyuncu, Can Fahrettin; Sokmensuer, Cenk; Gunduz-Demir, Cigdem
2015-01-01
In digital pathology, devising effective image representations is crucial to design robust automated diagnosis systems. To this end, many studies have proposed to develop object-based representations, instead of directly using image pixels, since a histopathological image may contain a considerable amount of noise typically at the pixel-level. These previous studies mostly employ color information to define their objects, which approximately represent histological tissue components in an image, and then use the spatial distribution of these objects for image representation and classification. Thus, object definition has a direct effect on the way of representing the image, which in turn affects classification accuracies. In this paper, our aim is to design a classification system for histopathological images. Towards this end, we present a new model for effective representation of these images that will be used by the classification system. The contributions of this model are twofold. First, it introduces a new two-tier tissue decomposition method for defining a set of multityped objects in an image. Different than the previous studies, these objects are defined combining texture, shape, and size information and they may correspond to individual histological tissue components as well as local tissue subregions of different characteristics. As its second contribution, it defines a new metric, which we call dominant blob scale, to characterize the shape and size of an object with a single scalar value. Our experiments on colon tissue images reveal that this new object definition and characterization provides distinguishing representation of normal and cancerous histopathological images, which is effective to obtain more accurate classification results compared to its counterparts.
Mass is all that matters in the size-weight illusion.
Plaisier, Myrthe A; Smeets, Jeroen B J
2012-01-01
An object in outer space is weightless due to the absence of gravity, but astronauts can still judge whether one object is heavier than another one by accelerating the object. How heavy an object feels depends on the exploration mode: an object is perceived as heavier when holding it against the pull of gravity than when accelerating it. At the same time, perceiving an object's size influences the percept: small objects feel heavier than large objects with the same mass (size-weight illusion). Does this effect depend on perception of the pull of gravity? To answer this question, objects were suspended from a long wire and participants were asked to push an object and rate its heaviness. This way the contribution of gravitational forces on the percept was minimised. Our results show that weight is not at all necessary for the illusion because the size-weight illusion occurred without perception of weight. The magnitude of the illusion was independent of whether inertial or gravitational forces were perceived. We conclude that the size-weight illusion does not depend on prior knowledge about weights of object, but instead on a more general knowledge about the mass of objects, independent of the contribution of gravity. Consequently, the size-weight illusion will have the same magnitude on Earth as it should have on the Moon or even under conditions of weightlessness.
Objects but not concepts modulate the size of the attended region.
Goodhew, Stephanie C; Edwards, Mark
2017-07-01
Here we investigated the types of stimuli that modulate the size of the attentional spotlight. In particular, it has been previously shown that conceptual cues that either directly refer to or are semantically related to particular spatial locations can shift attention to that location (known as "conceptual cueing"). For example, reading the word sun or joy can shift attention upward whereas the word boot or hostile can shift attention downward. Here, therefore, we tested whether words could modulate the size of the attended area. Across five experiments, we found that words that either directly referred to, or were abstractly associated with, particular sizes (small versus large) did not change the size of the attentional spotlight, whereas the presence of differently sized stimuli did, as evidenced by faster responses to targets when the spotlight is small than when it is large. This suggests that physical but not conceptual inducers can modulate the size of the attentional spotlight. This highlights an important difference between the regulation of spotlight size and shifts of attention, supporting the notion that they are subserved by distinct mechanisms.
Circuit-level optimisation of a:Si TFT-based AMOLED pixel circuits for maximum hold current
NASA Astrophysics Data System (ADS)
Foroughi, Aidin; Mehrpoo, Mohammadreza; Ashtiani, Shahin J.
2013-11-01
Design of AMOLED pixel circuits has manifold constraints and trade-offs which provides incentive for circuit designers to seek optimal solutions for different objectives. In this article, we present a discussion on the viability of an optimal solution to achieve the maximum hold current. A compact formula for component sizing in a conventional 2T1C pixel is, therefore, derived. Compared to SPICE simulation results, for several pixel sizes, our predicted optimum sizing yields maximum currents with errors less than 0.4%.
Structured Light-Based 3D Reconstruction System for Plants
Nguyen, Thuy Tuong; Slaughter, David C.; Max, Nelson; Maloof, Julin N.; Sinha, Neelima
2015-01-01
Camera-based 3D reconstruction of physical objects is one of the most popular computer vision trends in recent years. Many systems have been built to model different real-world subjects, but there is lack of a completely robust system for plants.This paper presents a full 3D reconstruction system that incorporates both hardware structures (including the proposed structured light system to enhance textures on object surfaces) and software algorithms (including the proposed 3D point cloud registration and plant feature measurement). This paper demonstrates the ability to produce 3D models of whole plants created from multiple pairs of stereo images taken at different viewing angles, without the need to destructively cut away any parts of a plant. The ability to accurately predict phenotyping features, such as the number of leaves, plant height, leaf size and internode distances, is also demonstrated. Experimental results show that, for plants having a range of leaf sizes and a distance between leaves appropriate for the hardware design, the algorithms successfully predict phenotyping features in the target crops, with a recall of 0.97 and a precision of 0.89 for leaf detection and less than a 13-mm error for plant size, leaf size and internode distance. PMID:26230701
A common visual metric for approximate number and density
Dakin, Steven C.; Tibber, Marc S.; Greenwood, John A.; Kingdom, Frederick A. A.; Morgan, Michael J.
2011-01-01
There is considerable interest in how humans estimate the number of objects in a scene in the context of an extensive literature on how we estimate the density (i.e., spacing) of objects. Here, we show that our sense of number and our sense of density are intertwined. Presented with two patches, observers found it more difficult to spot differences in either density or numerosity when those patches were mismatched in overall size, and their errors were consistent with larger patches appearing both denser and more numerous. We propose that density is estimated using the relative response of mechanisms tuned to low and high spatial frequencies (SFs), because energy at high SFs is largely determined by the number of objects, whereas low SF energy depends more on the area occupied by elements. This measure is biased by overall stimulus size in the same way as human observers, and by estimating number using the same measure scaled by relative stimulus size, we can explain all of our results. This model is a simple, biologically plausible common metric for perceptual number and density. PMID:22106276
Simulation on Poisson and negative binomial models of count road accident modeling
NASA Astrophysics Data System (ADS)
Sapuan, M. S.; Razali, A. M.; Zamzuri, Z. H.; Ibrahim, K.
2016-11-01
Accident count data have often been shown to have overdispersion. On the other hand, the data might contain zero count (excess zeros). The simulation study was conducted to create a scenarios which an accident happen in T-junction with the assumption the dependent variables of generated data follows certain distribution namely Poisson and negative binomial distribution with different sample size of n=30 to n=500. The study objective was accomplished by fitting Poisson regression, negative binomial regression and Hurdle negative binomial model to the simulated data. The model validation was compared and the simulation result shows for each different sample size, not all model fit the data nicely even though the data generated from its own distribution especially when the sample size is larger. Furthermore, the larger sample size indicates that more zeros accident count in the dataset.
Zhang, Xiao-Bo; Qu, Xian-You; Li, Meng; Wang, Hui; Jing, Zhi-Xian; Liu, Xiang; Zhang, Zhi-Wei; Guo, Lan-Ping; Huang, Lu-Qi
2017-11-01
After the end of the national and local medicine resources census work, a large number of Chinese medicine resources and distribution of data will be summarized. The species richness between the regions is a valid indicator for objective reflection of inter-regional resources of Chinese medicine. Due to the large difference in the size of the county area, the assessment of the intercropping of the resources of the traditional Chinese medicine by the county as a statistical unit will lead to the deviation of the regional abundance statistics. Based on the rule grid or grid statistical methods, the size of the statistical unit due to different can be reduced, the differences in the richness of traditional Chinese medicine resources are caused. Taking Chongqing as an example, based on the existing survey data, the difference of richness of traditional Chinese medicine resources under different grid scale were compared and analyzed. The results showed that the 30 km grid could be selected and the richness of Chinese medicine resources in Chongqing could reflect the objective situation of intercropping resources richness in traditional Chinese medicine better. Copyright© by the Chinese Pharmaceutical Association.
PATTERNS OF ROOT GROWTH, TURNOVER, AND DISTRIBUTION IN DIFFERENT AGED PONDEROSA PINE STANDS
The objectives of this study are to examine the spatial distribution of roots in relation to canopy size and tree distribution, and to determine if rates of fine root production and turnover are similar in the different aged stands. During the fall of 1998, 54 clear plexiglass t...
Interplay Between the Object and Its Symbol: The Size-Congruency Effect
Shen, Manqiong; Xie, Jiushu; Liu, Wenjuan; Lin, Wenjie; Chen, Zhuoming; Marmolejo-Ramos, Fernando; Wang, Ruiming
2016-01-01
Grounded cognition suggests that conceptual processing shares cognitive resources with perceptual processing. Hence, conceptual processing should be affected by perceptual processing, and vice versa. The current study explored the relationship between conceptual and perceptual processing of size. Within a pair of words, we manipulated the font size of each word, which was either congruent or incongruent with the actual size of the referred object. In Experiment 1a, participants compared object sizes that were referred to by word pairs. Higher accuracy was observed in the congruent condition (e.g., word pairs referring to larger objects in larger font sizes) than in the incongruent condition. This is known as the size-congruency effect. In Experiments 1b and 2, participants compared the font sizes of these word pairs. The size-congruency effect was not observed. In Experiments 3a and 3b, participants compared object and font sizes of word pairs depending on a task cue. Results showed that perceptual processing affected conceptual processing, and vice versa. This suggested that the association between conceptual and perceptual processes may be bidirectional but further modulated by semantic processing. Specifically, conceptual processing might only affect perceptual processing when semantic information is activated. The current study PMID:27512529
Sentence processing in anterior superior temporal cortex shows a social-emotional bias.
Mellem, Monika S; Jasmin, Kyle M; Peng, Cynthia; Martin, Alex
2016-08-01
The anterior region of the left superior temporal gyrus/superior temporal sulcus (aSTG/STS) has been implicated in two very different cognitive functions: sentence processing and social-emotional processing. However, the vast majority of the sentence stimuli in previous reports have been of a social or social-emotional nature suggesting that sentence processing may be confounded with semantic content. To evaluate this possibility we had subjects read word lists that differed in phrase/constituent size (single words, 3-word phrases, 6-word sentences) and semantic content (social-emotional, social, and inanimate objects) while scanned in a 7T environment. This allowed us to investigate if the aSTG/STS responded to increasing constituent structure (with increased activity as a function of constituent size) with or without regard to a specific domain of concepts, i.e., social and/or social-emotional content. Activity in the left aSTG/STS was found to increase with constituent size. This region was also modulated by content, however, such that social-emotional concepts were preferred over social and object stimuli. Reading also induced content type effects in domain-specific semantic regions. Those preferring social-emotional content included aSTG/STS, inferior frontal gyrus, posterior STS, lateral fusiform, ventromedial prefrontal cortex, and amygdala, regions included in the "social brain", while those preferring object content included parahippocampal gyrus, retrosplenial cortex, and caudate, regions involved in object processing. These results suggest that semantic content affects higher-level linguistic processing and should be taken into account in future studies. Copyright © 2016. Published by Elsevier Ltd.
Sharp and round shapes of seen objects have distinct influences on vowel and consonant articulation.
Vainio, L; Tiainen, M; Tiippana, K; Rantala, A; Vainio, M
2017-07-01
The shape and size-related sound symbolism phenomena assume that, for example, the vowel [i] and the consonant [t] are associated with sharp-shaped and small-sized objects, whereas [ɑ] and [m] are associated with round and large objects. It has been proposed that these phenomena are mostly based on the involvement of articulatory processes in representing shape and size properties of objects. For example, [i] might be associated with sharp and small objects, because it is produced by a specific front-close shape of articulators. Nevertheless, very little work has examined whether these object properties indeed have impact on speech sound vocalization. In the present study, the participants were presented with a sharp- or round-shaped object in a small or large size. They were required to pronounce one out of two meaningless speech units (e.g., [i] or [ɑ]) according to the size or shape of the object. We investigated how a task-irrelevant object property (e.g., the shape when responses are made according to size) influences reaction times, accuracy, intensity, fundamental frequency, and formant 1 and formant 2 of vocalizations. The size did not influence vocal responses but shape did. Specifically, the vowel [i] and consonant [t] were vocalized relatively rapidly when the object was sharp-shaped, whereas [u] and [m] were vocalized relatively rapidly when the object was round-shaped. The study supports the view that the shape-related sound symbolism phenomena might reflect mapping of the perceived shape with the corresponding articulatory gestures.
Contour Curvature As an Invariant Code for Objects in Visual Area V4
Pasupathy, Anitha
2016-01-01
Size-invariant object recognition—the ability to recognize objects across transformations of scale—is a fundamental feature of biological and artificial vision. To investigate its basis in the primate cerebral cortex, we measured single neuron responses to stimuli of varying size in visual area V4, a cornerstone of the object-processing pathway, in rhesus monkeys (Macaca mulatta). Leveraging two competing models for how neuronal selectivity for the bounding contours of objects may depend on stimulus size, we show that most V4 neurons (∼70%) encode objects in a size-invariant manner, consistent with selectivity for a size-independent parameter of boundary form: for these neurons, “normalized” curvature, rather than “absolute” curvature, provided a better account of responses. Our results demonstrate the suitability of contour curvature as a basis for size-invariant object representation in the visual cortex, and posit V4 as a foundation for behaviorally relevant object codes. SIGNIFICANCE STATEMENT Size-invariant object recognition is a bedrock for many perceptual and cognitive functions. Despite growing neurophysiological evidence for invariant object representations in the primate cortex, we still lack a basic understanding of the encoding rules that govern them. Classic work in the field of visual shape theory has long postulated that a representation of objects based on information about their bounding contours is well suited to mediate such an invariant code. In this study, we provide the first empirical support for this hypothesis, and its instantiation in single neurons of visual area V4. PMID:27194333
NASA Astrophysics Data System (ADS)
Gambi, J. M.; García del Pino, M. L.; Gschwindl, J.; Weinmüller, E. B.
2017-12-01
This paper deals with the problem of throwing middle-sized low Earth orbit debris objects into the atmosphere via laser ablation. The post-Newtonian equations here provided allow (hypothetical) space-based acquisition, pointing and tracking systems endowed with very narrow laser beams to reach the pointing accuracy presently prescribed. In fact, whatever the orbital elements of these objects may be, these equations will allow the operators to account for the corrections needed to balance the deviations of the line of sight directions due to the curvature of the paths the laser beams are to travel along. To minimize the respective corrections, the systems will have to perform initial positioning manoeuvres, and the shooting point-ahead angles will have to be adapted in real time. The enclosed numerical experiments suggest that neglecting these measures will cause fatal errors, due to differences in the actual locations of the objects comparable to their size.
Decreased attention to object size information in scale errors performers.
Grzyb, Beata J; Cangelosi, Angelo; Cattani, Allegra; Floccia, Caroline
2017-05-01
Young children sometimes make serious attempts to perform impossible actions on miniature objects as if they were full-size objects. The existing explanations of these curious action errors assume (but never explicitly tested) children's decreased attention to object size information. This study investigated the attention to object size information in scale errors performers. Two groups of children aged 18-25 months (N=52) and 48-60 months (N=23) were tested in two consecutive tasks: an action task that replicated the original scale errors elicitation situation, and a looking task that involved watching on a computer screen actions performed with adequate to inadequate size object. Our key finding - that children performing scale errors in the action task subsequently pay less attention to size changes than non-scale errors performers in the looking task - suggests that the origins of scale errors in childhood operate already at the perceptual level, and not at the action level. Copyright © 2017 Elsevier Inc. All rights reserved.
FitEM2EM—Tools for Low Resolution Study of Macromolecular Assembly and Dynamics
Frankenstein, Ziv; Sperling, Joseph; Sperling, Ruth; Eisenstein, Miriam
2008-01-01
Studies of the structure and dynamics of macromolecular assemblies often involve comparison of low resolution models obtained using different techniques such as electron microscopy or atomic force microscopy. We present new computational tools for comparing (matching) and docking of low resolution structures, based on shape complementarity. The matched or docked objects are represented by three dimensional grids where the value of each grid point depends on its position with regard to the interior, surface or exterior of the object. The grids are correlated using fast Fourier transformations producing either matches of related objects or docking models depending on the details of the grid representations. The procedures incorporate thickening and smoothing of the surfaces of the objects which effectively compensates for differences in the resolution of the matched/docked objects, circumventing the need for resolution modification. The presented matching tool FitEM2EMin successfully fitted electron microscopy structures obtained at different resolutions, different conformers of the same structure and partial structures, ranking correct matches at the top in every case. The differences between the grid representations of the matched objects can be used to study conformation differences or to characterize the size and shape of substructures. The presented low-to-low docking tool FitEM2EMout ranked the expected models at the top. PMID:18974836
Minimum Colour Differences Required To Recognise Small Objects On A Colour CRT
NASA Astrophysics Data System (ADS)
Phillips, Peter L.
1985-05-01
Data is required to assist in the assessment, evaluation and optimisation of colour and other displays for both military and general use. A general aim is to develop a mathematical technique to aid optimisation and reduce the amount of expensive hardware development and trials necessary when introducing new displays. The present standards and methods available for evaluating colour differences are known not to apply to the perception of typical objects on a display. Data is required for irregular objects viewed at small angular subtense ((1°) and relating the recognition of form rather than colour matching. Therefore laboratory experiments have been carried out using a computer controlled CRT to measure the threshold colour difference that an observer requires between object and background so that he can discriminate a variety of similar objects. Measurements are included for a variety of background and object colourings. The results are presented in the CIE colorimetric system similar to current standards used by the display engineer. Apart from the characteristic small field tritanopia, the results show that larger colour differences are required for object recognition than those assumed from conventional colour discrimination data. A simple relationship to account for object size and background colour is suggested to aid visual performance assessments and modelling.
Thermal History and Fragmentation of Ureilitic Asteroids: Insights from the Almahata Sitta Fall
NASA Technical Reports Server (NTRS)
Herrin, J. S.; Ito, M.; Zolensky, M. E.; Mittlefehldt, D. M.; Jenniskens, P. M.; Shaddad, M. H.
2010-01-01
Prior to recovery the Almahata Sitta fall was observed as the asteroid 2008 TC3 on an Earth-bound trajectory, providing a unique link between spectral data and ureilite composition. The event has also provided insight into the nature of ureilitic objects in space. In particular, the large size (4 m3) and low density (2.2 g/cm3) of the object combined with near-complete disintegration upon entry suggest a porous and loosely-consolidated body [1]. Accordingly, recovered fragments are small in size (1.5-283g) and represent several different ureilite lithologies. Some recovered fragments appear brecciated while others do not. We use chemical and mineralogic data to dissect the thermal history of this new ureilite, then use this information to compare the inferred size of fragments within the asteroid to those initially dislodged from a common ureilite parent body (UPB).
Distance and Size Perception in Astronauts during Long-Duration Spaceflight
Clément, Gilles; Skinner, Anna; Lathan, Corinna
2013-01-01
Exposure to microgravity during spaceflight is known to elicit orientation illusions, errors in sensory localization, postural imbalance, changes in vestibulo-spinal and vestibulo-ocular reflexes, and space motion sickness. The objective of this experiment was to investigate whether an alteration in cognitive visual-spatial processing, such as the perception of distance and size of objects, is also taking place during prolonged exposure to microgravity. Our results show that astronauts on board the International Space Station exhibit biases in the perception of their environment. Objects’ heights and depths were perceived as taller and shallower, respectively, and distances were generally underestimated in orbit compared to Earth. These changes may occur because the perspective cues for depth are less salient in microgravity or the eye-height scaling of size is different when an observer is not standing on the ground. This finding has operational implications for human space exploration missions. PMID:25369884
The paradoxical moon illusions.
Gilinsky, A S
1980-02-01
An adaptation theory of visual space is developed and applied to the data of a variety of studies of visual space perception. By distinguishing between the perceived distance of an object and that of the background or sky, the theory resolves the paradox of the moon illusions and relates both perceived size and perceived distance of the moon to the absolute level of spatial adaptation. The theory assumes that visual space expands or contracts in adjustment to changes in the sensory indicators of depth and provides a measure, A, of this adaptation-level. Changes in A have two effects--one on perceived size, one on perceived distance. Since A varies systematically as a function of angle of regard, availability of cues, and the total space-value, A is a measure of the moon illusions, and a practical index of individual differences by pilots and astronauts in the perception of the size and distance of objects on the ground and in the air.
Small numbers are sensed directly, high numbers constructed from size and density.
Zimmermann, Eckart
2018-04-01
Two theories compete to explain how we estimate the numerosity of visual object sets. The first suggests that the apparent numerosity is derived from an analysis of more low-level features like size and density of the set. The second theory suggests that numbers are sensed directly. Consistent with the latter claim is the existence of neurons in parietal cortex which are specialized for processing the numerosity of elements in the visual scene. However, recent evidence suggests that only low numbers can be sensed directly whereas the perception of high numbers is supported by the analysis of low-level features. Processing of low and high numbers, being located at different levels of the neural hierarchy should involve different receptive field sizes. Here, I tested this idea with visual adaptation. I measured the spatial spread of number adaptation for low and high numerosities. A focused adaptation spread of high numerosities suggested the involvement of early neural levels where receptive fields are comparably small and the broad spread for low numerosities was consistent with processing of number neurons which have larger receptive fields. These results provide evidence for the claim that different mechanism exist generating the perception of visual numerosity. Whereas low numbers are sensed directly as a primary visual attribute, the estimation of high numbers however likely depends on the area size over which the objects are spread. Copyright © 2017 Elsevier B.V. All rights reserved.
Does apparent size capture attention in visual search? Evidence from the Muller-Lyer illusion.
Proulx, Michael J; Green, Monique
2011-11-23
Is perceived size a crucial factor for the bottom-up guidance of attention? Here, a visual search experiment was used to examine whether an irrelevantly longer object can capture attention when participants were to detect a vertical target item. The longer object was created by an apparent size manipulation, the Müller-Lyer illusion; however, all objects contained the same number of pixels. The vertical target was detected more efficiently when it was also perceived as the longer item that was defined by apparent size. Further analysis revealed that the longer Müller-Lyer object received a greater degree of attentional priority than published results for other features such as retinal size, luminance contrast, and the abrupt onset of a new object. The present experiment has demonstrated for the first time that apparent size can capture attention and, thus, provide bottom-up guidance on the basis of perceived salience.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kenyon, Scott J.; Bromley, Benjamin C., E-mail: skenyon@cfa.harvard.edu, E-mail: bromley@physics.utah.edu
2012-03-15
We investigate whether coagulation models of planet formation can explain the observed size distributions of trans-Neptunian objects (TNOs). Analyzing published and new calculations, we demonstrate robust relations between the size of the largest object and the slope of the size distribution for sizes 0.1 km and larger. These relations yield clear, testable predictions for TNOs and other icy objects throughout the solar system. Applying our results to existing observations, we show that a broad range of initial disk masses, planetesimal sizes, and fragmentation parameters can explain the data. Adding dynamical constraints on the initial semimajor axis of 'hot' Kuiper Beltmore » objects along with probable TNO formation times of 10-700 Myr restricts the viable models to those with a massive disk composed of relatively small (1-10 km) planetesimals.« less
WISE Revises Numbers of Asteroids Near Earth
2011-09-29
Data from NASA Wide-field Infrared Survey Explorer has led to revisions in the estimated population of near-Earth asteroids. The most accurate survey to date has allowed new estimates of the total numbers of objects in different size categories.
Atlas of low-mass young stellar object disks from mid-infrared interferometry
NASA Astrophysics Data System (ADS)
Varga, J.; Ábrahám, P.; Ratzka, Th.; Menu, J.; Gabányi, K.; Kóspál, Á.; van Boekel, R.; Mosoni, L.; Henning, Th.
We present our approach of visibility modeling of disks around low-mass (< 2 M ⊙) young stellar objects (YSOs). We compiled an atlas based on mid-infrared interferometric observations from the MIDI instrument at the VLTI. We use three different models to fit the data. These models allow us to determine overall sizes (and the extent of the inner gaps) of the modeled circumstellar disks.
Velocity-based motion categorization by pigeons.
Cook, Robert G; Beale, Kevin; Koban, Angie
2011-04-01
To examine if animals could learn action-like categorizations in a manner similar to noun-based categories, eight pigeons were trained to categorize rates of object motion. Testing 40 different objects in a go/no-go discrimination, pigeons were first trained to discriminate between fast and slow rates of object rotation around their central y-axis. They easily learned this velocity discrimination and transferred it to novel objects and rates. This discrimination also transferred to novel types of motions including the other two axes of rotation and two new translations around the display. Comparable tests with rapid and slow changes in the objects' size, color, and shape failed to support comparable transfer. This difference in discrimination transfer between motion-based and property-based changes suggests the pigeons had learned motion concept rather than one based on change per se. The results provide evidence that pigeons can acquire an understanding of motion-based actions, at least with regard to the property of object velocity. This may be similar to our use of verbs and adverbs to categorize different classes of behavior or motion (e.g., walking, jogging, or running slow vs. fast).
Peel, Hayden J.; Sperandio, Irene; Laycock, Robin; Chouinard, Philippe A.
2018-01-01
Our understanding of how form, orientation and size are processed within and outside of awareness is limited and requires further investigation. Therefore, we investigated whether or not the visual discrimination of basic object features can be influenced by subliminal processing of stimuli presented beforehand. Visual masking was used to render stimuli perceptually invisible. Three experiments examined if visible and invisible primes could facilitate the subsequent feature discrimination of visible targets. The experiments differed in the kind of perceptual discrimination that participants had to make. Namely, participants were asked to discriminate visual stimuli on the basis of their form, orientation, or size. In all three experiments, we demonstrated reliable priming effects when the primes were visible but not when the primes were made invisible. Our findings underscore the importance of conscious awareness in facilitating the perceptual discrimination of basic object features. PMID:29725292
Peel, Hayden J; Sperandio, Irene; Laycock, Robin; Chouinard, Philippe A
2018-01-01
Our understanding of how form, orientation and size are processed within and outside of awareness is limited and requires further investigation. Therefore, we investigated whether or not the visual discrimination of basic object features can be influenced by subliminal processing of stimuli presented beforehand. Visual masking was used to render stimuli perceptually invisible. Three experiments examined if visible and invisible primes could facilitate the subsequent feature discrimination of visible targets. The experiments differed in the kind of perceptual discrimination that participants had to make. Namely, participants were asked to discriminate visual stimuli on the basis of their form, orientation, or size. In all three experiments, we demonstrated reliable priming effects when the primes were visible but not when the primes were made invisible. Our findings underscore the importance of conscious awareness in facilitating the perceptual discrimination of basic object features.
Mohammad-Beigi, Hossein; Shojaosadati, Seyed Abbas; Morshedi, Dina; Mirzazadeh, Negar; Arpanaei, Ayyoob
2016-01-01
Background Recently, applications of albumin nanoparticles as drug delivery carriers have increased. Most toxicology studies have shown that surface chemistry and size of nanoparticles play an important role in biocompatibility and toxicity. Objective The effect of desolvating agents with different chemical properties on the size of synthesized HSA NPs was investigated. Materials and Methods Acetone, ethanol, methanol, and acetonitrile were used to synthesize HSA NPs with controllable size by desolvation method. Scanning electron microscopy (SEM), dynamic light scattering (DLS), and circular dichroism (CD) were employed to characterize produced particles. Finally, the toxicity of HSA NPs synthesized under different conditions was evaluated on PC-12 cells. Results The sizes of synthesized particles differed according to the different solvents used. The sizes were 275.3 nm, 155.3 nm, 100.11 nm, and 66.2 nm for acetonitrile, ethanol, acetone, and methanol, respectively. CD showed that larger NPs had more changes in the secondary structures. Finally, the toxicity monitored on the cultured PC-12 cells showed no significant toxic effect through treating with these NPs at different concentrations (0-500 μg.mL-1). Conclusions The size of HSA NPs has a strong dependency on the desolvating agent. The mechanism in which the desolvating agent affects the size of HSA NPs is complex. Various factors such as dielectric constant, polarity, functional groups, and hydrogen bonding of the solvents have the potential to affect the size and structure of HSA NPs. CD analysis suggested that the solvent denaturing capability had a critical effect on the HSA particle size. The stronger denaturing capability of the solvent resulted in the larger HSA particle size. PMID:28959317
Annual cycle of size-resolved organic aerosol characterization in an urbanized desert environment
NASA Astrophysics Data System (ADS)
Cahill, Thomas M.
2013-06-01
Studies of size-resolved organic speciation of aerosols are still relatively rare and are generally only conducted over short durations. However, size-resolved organic data can both suggest possible sources of the aerosols and identify the human exposure to the chemicals since different aerosol sizes have different lung capture efficiencies. The objective of this study was to conduct size-resolved organic aerosol speciation for a calendar year in Phoenix, Arizona to determine the seasonal variations in both chemical concentrations and size profiles. The results showed large seasonal differences in combustion pollutants where the highest concentrations were observed in winter. Summertime aerosols have a greater proportion of biological compounds (e.g. sugars and fatty acids) and the biological compounds represent the largest fraction of the organic compounds detected. These results suggest that standard organic carbon (OC) measurements might be heavily influenced by primary biological compounds particularly if the samples are PM10 and TSP samples. Several large dust storms did not significantly alter the organic aerosol profile since Phoenix resides in a dusty desert environment, so the soil and plant tracer of trehalose was almost always present. The aerosol size profiles showed that PAHs were generally most abundant in the smallest aerosol size fractions, which are most likely to be captured by the lung, while the biological compounds were almost exclusively found in the coarse size fraction.
Walczak, Rafał; Antosik, Paweł; Sniadek, Patrycja; Piotrowska, Hanna; Bukowska, Dorota; Dziuban, Jan; Nowicki, Michał; Jaśkowski, Jędrzej M.; Brüssow, Klaus-Peter
2014-01-01
Since microfollicular environment and the size of the follicle are important markers influencing oocyte quality, the aim of this study is to present the spectral characterization of oocytes isolated from follicles of various sizes using lab-on-chip (LOC) technology and to demonstrate how follicle size may affect oocyte quality. Porcine oocytes (each, n = 100) recovered from follicles of different sizes, for example, from large (>5 mm), medium (3–5 mm), and small (<3 mm), were analyzed after preceding in vitro maturation (IVM). The LOC analysis was performed using a silicon-glass sandwich with two glass optical fibers positioned “face-to-face.” Oocytes collected from follicles of different size classes revealed specific and distinguishable spectral characteristics. The absorbance spectra (microspectrometric specificity) for oocytes isolated from large, medium, and small follicles differ significantly (P < 0.05) and the absorbance wavelengths were between 626 and 628 nm, between 618 and 620 nm, and less than 618 nm, respectively. The present study offers a parametric and objective method of porcine oocyte assessment. However, up to now this study has been used to evidence spectral markers associated with follicular size in pigs, only. Further investigations with functional-biological assays and comparing LOC analyses with fertilization and pregnancy success and the outcome of healthy offspring must be performed. PMID:25548771
Final Report to the Office of Naval Research
1991-10-18
microparticles suspended in the water. The main objective of the research was to develop, and experimentally verify, a theoretical model for the Laser Doppler (LD...components). This design allows great flexibility for positioning and scanning the laser beam in the water. (2) Special polystyrene microparticles were used...in the experiments. These microparticles were very uniform in shape (spherical) and size. Three different sizes were used - 0.1pm, lpm and 10pm radius
Overweight in Adolescents: Differences per Type of Education. Does One Size Fit All?
ERIC Educational Resources Information Center
Vissers, Dirk; Devoogdt, Nele; Gebruers, Nick; Mertens, Ilse; Truijen, Steven; Van Gaal, Luc
2008-01-01
Objective: To assess the lifestyle and prevalence of overweight among 16- to 18-year-old adolescents attending 4 different types of secondary education (SE). Design: Cross-sectional school-based survey. Participants: A community sample of 994 adolescents (body mass index [BMI]: 15-43 kg/m[superscript 2]). Variables Measured: Overweight and obesity…
How Far Is "Near"? Inferring Distance from Spatial Descriptions
ERIC Educational Resources Information Center
Carlson, Laura A.; Covey, Eric S.
2005-01-01
A word may mean different things in different contexts. The current study explored the changing denotations of spatial terms, focusing on how the distance inferred from a spatial description varied as a function of the size of the objects being spatially related. We examined both terms that explicitly convey distance (i.e., topological terms such…
Volumetric Security Alarm Based on a Spherical Ultrasonic Transducer Array
NASA Astrophysics Data System (ADS)
Sayin, Umut; Scaini, Davide; Arteaga, Daniel
Most of the existent alarm systems depend on physical or visual contact. The detection area is often limited depending on the type of the transducer, creating blind spots. Our proposition is a truly volumetric alarm system that can detect any movement in the intrusion area, based on monitoring the change over time of the impulse response of the room, which acts as an acoustic footprint. The device depends on an omnidirectional ultrasonic transducer array emitting sweep signals to calculate the impulse response in short intervals. Any change in the room conditions is monitored through a correlation function. The sensitivity of the alarm to different objects and different environments depends on the sweep duration, sweep bandwidth, and sweep interval. Successful detection of intrusions also depends on the size of the monitoring area and requires an adjustment of emitted ultrasound power. Strong air flow affects the performance of the alarm. A method for separating moving objects from strong air flow is devised using an adaptive thresholding on the correlation function involving a series of impulse response measurements. The alarm system can be also used for fire detection since air flow sourced from heating objects differ from random nature of the present air flow. Several measurements are made to test the integrity of the alarm in rooms sizing from 834-2080m3 with irregular geometries and various objects. The proposed system can efficiently detect intrusion whilst adequate emitting power is provided.
Grossberg, Stephen; Markowitz, Jeffrey; Cao, Yongqiang
2011-12-01
Visual object recognition is an essential accomplishment of advanced brains. Object recognition needs to be tolerant, or invariant, with respect to changes in object position, size, and view. In monkeys and humans, a key area for recognition is the anterior inferotemporal cortex (ITa). Recent neurophysiological data show that ITa cells with high object selectivity often have low position tolerance. We propose a neural model whose cells learn to simulate this tradeoff, as well as ITa responses to image morphs, while explaining how invariant recognition properties may arise in stages due to processes across multiple cortical areas. These processes include the cortical magnification factor, multiple receptive field sizes, and top-down attentive matching and learning properties that may be tuned by task requirements to attend to either concrete or abstract visual features with different levels of vigilance. The model predicts that data from the tradeoff and image morph tasks emerge from different levels of vigilance in the animals performing them. This result illustrates how different vigilance requirements of a task may change the course of category learning, notably the critical features that are attended and incorporated into learned category prototypes. The model outlines a path for developing an animal model of how defective vigilance control can lead to symptoms of various mental disorders, such as autism and amnesia. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Bambina, Alexandre; Yamaguchi, Shuhei; Iwai, Akinori; Miyagi, Shigeyuki; Sakai, Osamu
2018-01-01
Limitation of the cloak-size reduction is investigated numerically by a finite-difference time-domain (FDTD) method. A metallic pole that imitates an antenna is cloaked with an anisotropic and parameter-gradient medium against electromagnetic-wave propagation in microwave range. The cloaking structure is a metamaterial submerged in a plasma confined in a vacuum chamber made of glass. The smooth-permittivity plasma can be compressed in the radial direction, which enables us to decrease the size of the cloak. Theoretical analysis is performed numerically by comparing scattering waves in various cases; there exists a high reduction of the scattering wave when the radius of the cloak is larger than a quarter of one wavelength. This result indicates that the required size of the cloaking layer is more than an object scale in the Rayleigh scattering regime.
Size Does Matter: Implied Object Size is Mentally Simulated during Language Comprehension
ERIC Educational Resources Information Center
de Koning, Björn B.; Wassenburg, Stephanie I.; Bos, Lisanne T.; Van der Schoot, Menno
2017-01-01
Embodied theories of language comprehension propose that readers construct a mental simulation of described objects that contains perceptual characteristics of their real-world referents. The present study is the first to investigate directly whether implied object size is mentally simulated during sentence comprehension and to study the potential…
NASA Technical Reports Server (NTRS)
Mulrooney, Dr. Mark K.; Matney, Dr. Mark J.
2007-01-01
Orbital object data acquired via optical telescopes can play a crucial role in accurately defining the space environment. Radar systems probe the characteristics of small debris by measuring the reflected electromagnetic energy from an object of the same order of size as the wavelength of the radiation. This signal is affected by electrical conductivity of the bulk of the debris object, as well as its shape and orientation. Optical measurements use reflected solar radiation with wavelengths much smaller than the size of the objects. Just as with radar, the shape and orientation of an object are important, but we only need to consider the surface electrical properties of the debris material (i.e., the surface albedo), not the bulk electromagnetic properties. As a result, these two methods are complementary in that they measure somewhat independent physical properties to estimate the same thing, debris size. Short arc optical observations such as are typical of NASA's Liquid Mirror Telescope (LMT) give enough information to estimate an Assumed Circular Orbit (ACO) and an associated range. This information, combined with the apparent magnitude, can be used to estimate an "absolute" brightness (scaled to a fixed range and phase angle). This absolute magnitude is what is used to estimate debris size. However, the shape and surface albedo effects make the size estimates subject to systematic and random errors, such that it is impossible to ascertain the size of an individual object with any certainty. However, as has been shown with radar debris measurements, that does not preclude the ability to estimate the size distribution of a number of objects statistically. After systematic errors have been eliminated (range errors, phase function assumptions, photometry) there remains a random geometric albedo distribution that relates object size to absolute magnitude. Measurements by the LMT of a subset of tracked debris objects with sizes estimated from their radar cross sections indicate that the random variations in the albedo follow a log-normal distribution quite well. In addition, this distribution appears to be independent of object size over a considerable range in size. Note that this relation appears to hold for debris only, where the shapes and other properties are not primarily the result of human manufacture, but of random processes. With this information in hand, it now becomes possible to estimate the actual size distribution we are sampling from. We have identified two characteristics of the space debris population that make this process tractable and by extension have developed a methodology for performing the transformation.
Isolation of nanoscale exosomes using viscoelastic effect
NASA Astrophysics Data System (ADS)
Hu, Guoqing; Liu, Chao
2017-11-01
Exosomes, molecular cargos secreted by almost all mammalian cells, are considered as promising biomarkers to identify many diseases including cancers. However, the small size of exosomes (30-200 nm) poses serious challenges on their isolation from the complex media containing a variety of extracellular vesicles (EVs) of different sizes, especially in small sample volumes. Here we develop a viscoelasticity-based microfluidic system to directly separate exosomes from cell culture media or serum in a continuous, size-dependent, and label-free manner. Using a small amount of biocompatible polymer as the additive into the media to control the viscoelastic forces exerted on EVs, we are able to achieve a high separation purity (>90%) and recovery (>80%) of exosomes. The size cutoff in viscoelasticity-based microfluidics can be easily controlled using different PEO concentrations. Based on this size-dependent viscoelastic separation strategy, we envision the handling of diverse nanoscale objects, such as gold nanoparticles, DNA origami structures, and quantum dots. This work was supported financially by National Natural Science Foundation of China (11572334, 91543125).
Observations Regarding Scatter Fraction and NEC Measurements for Small Animal PET
NASA Astrophysics Data System (ADS)
Yang, Yongfeng; Cherry, S. R.
2006-02-01
The goal of this study was to evaluate the magnitude and origin of scattered radiation in a small-animal PET scanner and to assess the impact of these findings on noise equivalent count rate (NECR) measurements, a metric often used to optimize scanner acquisition parameters and to compare one scanner with another. The scatter fraction (SF) was measured for line sources in air and line sources placed within a mouse-sized phantom (25 mm /spl phi//spl times/70 mm) and a rat-sized phantom (60 mm /spl phi//spl times/150 mm) on the microPET II small-animal PET scanner. Measurements were performed for lower energy thresholds ranging from 150-450 keV and a fixed upper energy threshold of 750 keV. Four different methods were compared for estimating the SF. Significant scatter fractions were measured with just the line source in the field of view, with the spatial distribution of these events consistent with scatter from the gantry and room environment. For mouse imaging, this component dominates over object scatter, and the measured SF is strongly method dependent. The environmental SF rapidly increases as the lower energy threshold decreases and can be more than 30% for an open energy window of 150-750 keV. The object SF originating from the mouse phantom is about 3-4% and does not change significantly as the lower energy threshold increases. The object SF for the rat phantom ranges from 10 to 35% for different energy windows and increases as the lower energy threshold decreases. Because the measured SF is highly dependent on the method, and there is as yet no agreed upon standard for animal PET, care must be exercised when comparing NECR for small objects between different scanners. Differences may be methodological rather than reflecting any relevant difference in the performance of the scanner. Furthermore, these results have implications for scatter correction methods when the majority of the detected scatter does not arise from the object itself.
Dixon, Melissa W; Proffitt, Dennis R
2002-01-01
One important aspect of the pictorial representation of a scene is the depiction of object proportions. Yang, Dixon, and Proffitt (1999 Perception 28 445-467) recently reported that the magnitude of the vertical-horizontal illusion was greater for vertical extents presented in three-dimensional (3-D) environments compared to two-dimensional (2-D) displays. However, because all of the 3-D environments were large and all of the 2-D displays were small, the question remains whether the observed magnitude differences were due solely to the dimensionality of the displays (2-D versus 3-D) or to the perceived distal size of the extents (small versus large). We investigated this question by comparing observers' judgments of vertical relative to horizontal extents on a large but 2-D display compared to the large 3-D and the small 2-D displays used by Yang et al (1999). The results confirmed that the magnitude differences for vertical overestimation between display media are influenced more by the perceived distal object size rather than by the dimensionality of the display.
NASA Technical Reports Server (NTRS)
Dixon, Melissa W.; Proffitt, Dennis R.; Kaiser, M. K. (Principal Investigator)
2002-01-01
One important aspect of the pictorial representation of a scene is the depiction of object proportions. Yang, Dixon, and Proffitt (1999 Perception 28 445-467) recently reported that the magnitude of the vertical-horizontal illusion was greater for vertical extents presented in three-dimensional (3-D) environments compared to two-dimensional (2-D) displays. However, because all of the 3-D environments were large and all of the 2-D displays were small, the question remains whether the observed magnitude differences were due solely to the dimensionality of the displays (2-D versus 3-D) or to the perceived distal size of the extents (small versus large). We investigated this question by comparing observers' judgments of vertical relative to horizontal extents on a large but 2-D display compared to the large 3-D and the small 2-D displays used by Yang et al (1999). The results confirmed that the magnitude differences for vertical overestimation between display media are influenced more by the perceived distal object size rather than by the dimensionality of the display.
Stroke-model-based character extraction from gray-level document images.
Ye, X; Cheriet, M; Suen, C Y
2001-01-01
Global gray-level thresholding techniques such as Otsu's method, and local gray-level thresholding techniques such as edge-based segmentation or the adaptive thresholding method are powerful in extracting character objects from simple or slowly varying backgrounds. However, they are found to be insufficient when the backgrounds include sharply varying contours or fonts in different sizes. A stroke-model is proposed to depict the local features of character objects as double-edges in a predefined size. This model enables us to detect thin connected components selectively, while ignoring relatively large backgrounds that appear complex. Meanwhile, since the stroke width restriction is fully factored in, the proposed technique can be used to extract characters in predefined font sizes. To process large volumes of documents efficiently, a hybrid method is proposed for character extraction from various backgrounds. Using the measurement of class separability to differentiate images with simple backgrounds from those with complex backgrounds, the hybrid method can process documents with different backgrounds by applying the appropriate methods. Experiments on extracting handwriting from a check image, as well as machine-printed characters from scene images demonstrate the effectiveness of the proposed model.
Terrestrial-passage theory: failing a test.
Reed, Charles F; Krupinski, Elizabeth A
2009-01-01
Terrestrial-passage theory proposes that the 'moon' and 'sky' illusions occur because observers learn to expect an elevation-dependent transformation of visual angle. The transformation accompanies daily movement through ordinary environments of fixed-altitude objects. Celestial objects display the same visual angle at all elevations, and hence are necessarily non-conforming with the ordinary transformation. On hypothesis, observers should target angular sizes to appear greater at elevation than at horizon. However, in a sample of forty-eight observers there was no significant difference between the perceived angular size of a constellation of stars at horizon and that predicted for a specific elevation. Occurrence of the illusion was not restricted to those observers who expected angular expansion. These findings fail to support the terrestrial-passage theory of the illusion.
Remote object authentication: confidence model, cryptosystem and protocol
NASA Astrophysics Data System (ADS)
Lancrenon, Jean; Gillard, Roland; Fournel, Thierry
2009-04-01
This paper follows a paper by Bringer et al.3 to adapt a security model and protocol used for remote biometric authentication to the case of remote morphometric object authentication. We use a different type of encryption technique that requires smaller key sizes and has a built-in mechanism to help control the integrity of the messages received by the server. We also describe the optical technology used to extract the morphometric templates.
Object width modulates object-based attentional selection.
Nah, Joseph C; Neppi-Modona, Marco; Strother, Lars; Behrmann, Marlene; Shomstein, Sarah
2018-04-24
Visual input typically includes a myriad of objects, some of which are selected for further processing. While these objects vary in shape and size, most evidence supporting object-based guidance of attention is drawn from paradigms employing two identical objects. Importantly, object size is a readily perceived stimulus dimension, and whether it modulates the distribution of attention remains an open question. Across four experiments, the size of the objects in the display was manipulated in a modified version of the two-rectangle paradigm. In Experiment 1, two identical parallel rectangles of two sizes (thin or thick) were presented. Experiments 2-4 employed identical trapezoids (each having a thin and thick end), inverted in orientation. In the experiments, one end of an object was cued and participants performed either a T/L discrimination or a simple target-detection task. Combined results show that, in addition to the standard object-based attentional advantage, there was a further attentional benefit for processing information contained in the thick versus thin end of objects. Additionally, eye-tracking measures demonstrated increased saccade precision towards thick object ends, suggesting that Fitts's Law may play a role in object-based attentional shifts. Taken together, these results suggest that object-based attentional selection is modulated by object width.
Simulating the X-ray luminosity of Be X-ray binaries: the case for black holes versus neutron stars
NASA Astrophysics Data System (ADS)
Brown, R. O.; Ho, W. C. G.; Coe, M. J.; Okazaki, A. T.
2018-04-01
There are over 100 Be stars that are known to have neutron star companions but only one such system with a black hole. Previous theoretical work suggests this is not due to their formation but due to differences in X-ray luminosity. It has also been proposed that the truncation of the Be star's circumstellar disc is dependent on the mass of the compact object. Hence, Be star discs in black hole binaries are smaller. Since accretion onto the compact object from the Be star's disc is what powers the X-ray luminosity, a smaller disc in black hole systems leads to a lower luminosity. In this paper, simulations are performed with a range of eccentricities and compact object mass. The disc's size and density are shown to be dependent on both quantities. Mass capture and, in turn, X-ray luminosity are heavily dependent on the size and density of the disc. Be/black hole binaries are expected to be up to ˜10 times fainter than Be/neutron star binaries when both systems have the same eccentricity and can be 100 times fainter when comparing systems with different eccentricity.
Two schemes for quantitative photoacoustic tomography based on Monte Carlo simulation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Liu, Yubin; Yuan, Zhen, E-mail: zhenyuan@umac.mo
Purpose: The aim of this study was to develop novel methods for photoacoustically determining the optical absorption coefficient of biological tissues using Monte Carlo (MC) simulation. Methods: In this study, the authors propose two quantitative photoacoustic tomography (PAT) methods for mapping the optical absorption coefficient. The reconstruction methods combine conventional PAT with MC simulation in a novel way to determine the optical absorption coefficient of biological tissues or organs. Specifically, the authors’ two schemes were theoretically and experimentally examined using simulations, tissue-mimicking phantoms, ex vivo, and in vivo tests. In particular, the authors explored these methods using several objects withmore » different absorption contrasts embedded in turbid media and by using high-absorption media when the diffusion approximation was not effective at describing the photon transport. Results: The simulations and experimental tests showed that the reconstructions were quantitatively accurate in terms of the locations, sizes, and optical properties of the targets. The positions of the recovered targets were accessed by the property profiles, where the authors discovered that the off center error was less than 0.1 mm for the circular target. Meanwhile, the sizes and quantitative optical properties of the targets were quantified by estimating the full width half maximum of the optical absorption property. Interestingly, for the reconstructed sizes, the authors discovered that the errors ranged from 0 for relatively small-size targets to 26% for relatively large-size targets whereas for the recovered optical properties, the errors ranged from 0% to 12.5% for different cases. Conclusions: The authors found that their methods can quantitatively reconstruct absorbing objects of different sizes and optical contrasts even when the diffusion approximation is unable to accurately describe the photon propagation in biological tissues. In particular, their methods are able to resolve the intrinsic difficulties that occur when quantitative PAT is conducted by combining conventional PAT with the diffusion approximation or with radiation transport modeling.« less
Vasudevamurthy, G.; Byun, T. S.; Pappano, Pete; ...
2015-03-13
Here we present a comparison of the measured baseline mechanical and physical properties of with grain (WG) and against grain (AG) non-ASTM size NBG-18 graphite. The objectives of the experiments were twofold: (1) assess the variation in properties with grain orientation; (2) establish a correlation between specimen tensile strength and size. The tensile strength of the smallest sized (4 mm diameter) specimens were about 5% higher than the standard specimens (12 mm diameter) but still within one standard deviation of the ASTM specimen size indicating no significant dependence of strength on specimen size. The thermal expansion coefficient and elastic constantsmore » did not show significant dependence on specimen size. Lastly, experimental data indicated that the variation of thermal expansion coefficient and elastic constants were still within 5% between the different grain orientations, confirming the isotropic nature of NBG-18 graphite in physical properties.« less
Object Classification With Joint Projection and Low-Rank Dictionary Learning.
Foroughi, Homa; Ray, Nilanjan; Hong Zhang
2018-02-01
For an object classification system, the most critical obstacles toward real-world applications are often caused by large intra-class variability, arising from different lightings, occlusion, and corruption, in limited sample sets. Most methods in the literature would fail when the training samples are heavily occluded, corrupted or have significant illumination or viewpoint variations. Besides, most of the existing methods and especially deep learning-based methods, need large training sets to achieve a satisfactory recognition performance. Although using the pre-trained network on a generic large-scale data set and fine-tune it to the small-sized target data set is a widely used technique, this would not help when the content of base and target data sets are very different. To address these issues simultaneously, we propose a joint projection and low-rank dictionary learning method using dual graph constraints. Specifically, a structured class-specific dictionary is learned in the low-dimensional space, and the discrimination is further improved by imposing a graph constraint on the coding coefficients, that maximizes the intra-class compactness and inter-class separability. We enforce structural incoherence and low-rank constraints on sub-dictionaries to reduce the redundancy among them, and also make them robust to variations and outliers. To preserve the intrinsic structure of data, we introduce a supervised neighborhood graph into the framework to make the proposed method robust to small-sized and high-dimensional data sets. Experimental results on several benchmark data sets verify the superior performance of our method for object classification of small-sized data sets, which include a considerable amount of different kinds of variation, and may have high-dimensional feature vectors.
Patterns of muscle activity underlying object-specific grasp by the macaque monkey.
Brochier, T; Spinks, R L; Umilta, M A; Lemon, R N
2004-09-01
During object grasp, a coordinated activation of distal muscles is required to shape the hand in relation to the physical properties of the object. Despite the fundamental importance of the grasping action, little is known of the muscular activation patterns that allow objects of different sizes and shapes to be grasped. In a study of two adult macaque monkeys, we investigated whether we could distinguish between EMG activation patterns associated with grasp of 12 differently shaped objects, chosen to evoke a wide range of grasping postures. Each object was mounted on a horizontal shuttle held by a weak spring (load force 1-2 N). Objects were located in separate sectors of a "carousel," and inter-trial rotation of the carousel allowed sequential presentation of the objects in pseudorandom order. EMG activity from 10 to 12 digit, hand, and arm muscles was recorded using chronically implanted electrodes. We show that the grasp of different objects was characterized by complex but distinctive patterns of EMG activation. Cluster analysis shows that these object-related EMG patterns were specific and consistent enough to identify the object unequivocally from the EMG recordings alone. EMG-based object identification required a minimum of six EMGs from simultaneously recorded muscles. EMG patterns were consistent across recording sessions in a given monkey but showed some differences between animals. These results identify the specific patterns of activity required to achieve distinct hand postures for grasping, and they open the way to our understanding of how these patterns are generated by the central motor network.
Teaching Astronomy in non-formal education: stars workshop
NASA Astrophysics Data System (ADS)
Hernán-Obispo, M.; Crespo-Chacón, I.; Gálvez, M. C.; López-Santiago, J.
One of the fields in which teaching Astronomy is more demanded is non-formal education. The Stars Workshop we present in this contribution consisted on an introduction to Astronomy and observation methods. The main objectives were: to know the main components of the Universe, their characteristics and the scales of size and time existing between them; to understand the movement of the different celestial objects; to know the different observational techniques; to value the different historical explanations about the Earth and the position of Humanity in the Universe. This Stars Workshop was a collaboration with the Escuela de Tiempo Libre Jumavi, which is a school dedicated to the training and non-formal education in the leisure field.
Belcher, Annabelle M; Harrington, Rebecca A; Malkova, Ludise; Mishkin, Mortimer
2006-01-01
Earlier studies found that recognition memory for object-place associations was impaired in patients with relatively selective hippocampal damage (Vargha-Khadem et al., Science 1997; 277:376-380), but was unaffected after selective hippocampal lesions in monkeys (Malkova and Mishkin, J Neurosci 2003; 23:1956-1965). A potentially important methodological difference between the two studies is that the patients were required to remember a set of 20 object-place associations for several minutes, whereas the monkeys had to remember only two such associations at a time, and only for a few seconds. To approximate more closely the task given to the patients, we trained monkeys on several successive sets of 10 object-place pairs each, with each set requiring learning across days. Despite the increased associative memory demands, monkeys given hippocampal lesions were unimpaired relative to their unoperated controls, suggesting that differences other than set size and memory duration underlie the different outcomes in the human and animal studies. (c) 2005 Wiley-Liss, Inc.
The zebrafish world of colors and shapes: preference and discrimination.
Oliveira, Jessica; Silveira, Mayara; Chacon, Diana; Luchiari, Ana
2015-04-01
Natural environment imposes many challenges to animals, which have to use cognitive abilities to cope with and exploit it to enhance their fitness. Since zebrafish is a well-established model for cognitive studies and high-throughput screening for drugs and diseases that affect cognition, we tested their ability for ambient color preference and 3D objects discrimination to establish a protocol for memory evaluation. For the color preference test, zebrafish were observed in a multiple-chamber tank with different environmental color options. Zebrafish showed preference for blue and green, and avoided yellow and red. For the 3D objects discrimination, zebrafish were allowed to explore two equal objects and then observed in a one-trial test in which a new color, size, or shape of the object was presented. Zebrafish showed discrimination for color, shape, and color+shape combined, but not size. These results imply that zebrafish seem to use some categorical system to discriminate items, and distracters affect their ability for discrimination. The type of variables available (color and shape) may favor zebrafish objects perception and facilitate discrimination processing. We suggest that this easy and simple memory test could serve as a useful screening tool for cognitive dysfunction and neurotoxicological studies.
Investigation of the Iterative Phase Retrieval Algorithm for Interferometric Applications
NASA Astrophysics Data System (ADS)
Gombkötő, Balázs; Kornis, János
2010-04-01
Sequentially recorded intensity patterns reflected from a coherently illuminated diffuse object can be used to reconstruct the complex amplitude of the scattered beam. Several iterative phase retrieval algorithms are known in the literature to obtain the initially unknown phase from these longitudinally displaced intensity patterns. When two sequences are recorded in two different states of a centimeter sized object in optical setups that are similar to digital holographic interferometry-but omitting the reference wave-, displacement, deformation, or shape measurement is theoretically possible. To do this, the retrieved phase pattern should contain information not only about the intensities and locations of the point sources of the object surface, but their relative phase as well. Not only experiments require strict mechanical precision to record useful data, but even in simulations several parameters influence the capabilities of iterative phase retrieval, such as object to camera distance range, uniform or varying camera step sequence, speckle field characteristics, and sampling. Experiments were done to demonstrate this principle with an as large as 5×5 cm sized deformable object as well. Good initial results were obtained in an imaging setup, where the intensity pattern sequences were recorded near the image plane.
Change Detection Algorithms for Surveillance in Visual IoT: A Comparative Study
NASA Astrophysics Data System (ADS)
Akram, Beenish Ayesha; Zafar, Amna; Akbar, Ali Hammad; Wajid, Bilal; Chaudhry, Shafique Ahmad
2018-01-01
The VIoT (Visual Internet of Things) connects virtual information world with real world objects using sensors and pervasive computing. For video surveillance in VIoT, ChD (Change Detection) is a critical component. ChD algorithms identify regions of change in multiple images of the same scene recorded at different time intervals for video surveillance. This paper presents performance comparison of histogram thresholding and classification ChD algorithms using quantitative measures for video surveillance in VIoT based on salient features of datasets. The thresholding algorithms Otsu, Kapur, Rosin and classification methods k-means, EM (Expectation Maximization) were simulated in MATLAB using diverse datasets. For performance evaluation, the quantitative measures used include OSR (Overall Success Rate), YC (Yule's Coefficient) and JC (Jaccard's Coefficient), execution time and memory consumption. Experimental results showed that Kapur's algorithm performed better for both indoor and outdoor environments with illumination changes, shadowing and medium to fast moving objects. However, it reflected degraded performance for small object size with minor changes. Otsu algorithm showed better results for indoor environments with slow to medium changes and nomadic object mobility. k-means showed good results in indoor environment with small object size producing slow change, no shadowing and scarce illumination changes.
Baijal, Shruti; Nakatani, Chie; van Leeuwen, Cees; Srinivasan, Narayanan
2013-06-07
Human observers show remarkable efficiency in statistical estimation; they are able, for instance, to estimate the mean size of visual objects, even if their number exceeds the capacity limits of focused attention. This ability has been understood as the result of a distinct mode of attention, i.e. distributed attention. Compared to the focused attention mode, working memory representations under distributed attention are proposed to be more compressed, leading to reduced working memory loads. An alternate proposal is that distributed attention uses less structured, feature-level representations. These would fill up working memory (WM) more, even when target set size is low. Using event-related potentials, we compared WM loading in a typical distributed attention task (mean size estimation) to that in a corresponding focused attention task (object recognition), using a measure called contralateral delay activity (CDA). Participants performed both tasks on 2, 4, or 8 different-sized target disks. In the recognition task, CDA amplitude increased with set size; notably, however, in the mean estimation task the CDA amplitude was high regardless of set size. In particular for set-size 2, the amplitude was higher in the mean estimation task than in the recognition task. The result showed that the task involves full WM loading even with a low target set size. This suggests that in the distributed attention mode, representations are not compressed, but rather less structured than under focused attention conditions. Copyright © 2012 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Luo, Aiwen; An, Fengwei; Zhang, Xiangyu; Chen, Lei; Huang, Zunkai; Jürgen Mattausch, Hans
2018-04-01
Feature extraction techniques are a cornerstone of object detection in computer-vision-based applications. The detection performance of vison-based detection systems is often degraded by, e.g., changes in the illumination intensity of the light source, foreground-background contrast variations or automatic gain control from the camera. In order to avoid such degradation effects, we present a block-based L1-norm-circuit architecture which is configurable for different image-cell sizes, cell-based feature descriptors and image resolutions according to customization parameters from the circuit input. The incorporated flexibility in both the image resolution and the cell size for multi-scale image pyramids leads to lower computational complexity and power consumption. Additionally, an object-detection prototype for performance evaluation in 65 nm CMOS implements the proposed L1-norm circuit together with a histogram of oriented gradients (HOG) descriptor and a support vector machine (SVM) classifier. The proposed parallel architecture with high hardware efficiency enables real-time processing, high detection robustness, small chip-core area as well as low power consumption for multi-scale object detection.
Design of Phase II Non-inferiority Trials.
Jung, Sin-Ho
2017-09-01
With the development of inexpensive treatment regimens and less invasive surgical procedures, we are confronted with non-inferiority study objectives. A non-inferiority phase III trial requires a roughly four times larger sample size than that of a similar standard superiority trial. Because of the large required sample size, we often face feasibility issues to open a non-inferiority trial. Furthermore, due to lack of phase II non-inferiority trial design methods, we do not have an opportunity to investigate the efficacy of the experimental therapy through a phase II trial. As a result, we often fail to open a non-inferiority phase III trial and a large number of non-inferiority clinical questions still remain unanswered. In this paper, we want to develop some designs for non-inferiority randomized phase II trials with feasible sample sizes. At first, we review a design method for non-inferiority phase III trials. Subsequently, we propose three different designs for non-inferiority phase II trials that can be used under different settings. Each method is demonstrated with examples. Each of the proposed design methods is shown to require a reasonable sample size for non-inferiority phase II trials. The three different non-inferiority phase II trial designs are used under different settings, but require similar sample sizes that are typical for phase II trials.
Spatial coding of object typical size: evidence for a SNARC-like effect.
Sellaro, Roberta; Treccani, Barbara; Job, Remo; Cubelli, Roberto
2015-11-01
The present study aimed to assess whether the representation of the typical size of objects can interact with response position codes in two-choice bimanual tasks, and give rise to a SNARC-like effect (faster responses when the representation of the typical size of the object to which the target stimulus refers corresponds to response side). Participants performed either a magnitude comparison task (in which they were required to judge whether the target was smaller or larger than a reference stimulus; Experiment 1) or a semantic decision task (in which they had to classify the target as belonging to either the category of living or non-living entities; Experiment 2). Target stimuli were pictures or written words referring to either typically large and small animals or inanimate objects. In both tasks, participants responded by pressing a left- or right-side button. Results showed that, regardless of the to-be-performed task (magnitude comparison or semantic decision) and stimulus format (picture or word), left responses were faster when the target represented typically small-sized entities, whereas right responses were faster for typically large-sized entities. These results provide evidence that the information about the typical size of objects is activated even if it is not requested by the task, and are consistent with the idea that objects' typical size is automatically spatially coded, as has been proposed to occur for number magnitudes. In this representation, small objects would be on the left and large objects would be on the right. Alternative interpretations of these results are also discussed.
Recognition-induced forgetting is not due to category-based set size.
Maxcey, Ashleigh M
2016-01-01
What are the consequences of accessing a visual long-term memory representation? Previous work has shown that accessing a long-term memory representation via retrieval improves memory for the targeted item and hurts memory for related items, a phenomenon called retrieval-induced forgetting. Recently we found a similar forgetting phenomenon with recognition of visual objects. Recognition-induced forgetting occurs when practice recognizing an object during a two-alternative forced-choice task, from a group of objects learned at the same time, leads to worse memory for objects from that group that were not practiced. An alternative explanation of this effect is that category-based set size is inducing forgetting, not recognition practice as claimed by some researchers. This alternative explanation is possible because during recognition practice subjects make old-new judgments in a two-alternative forced-choice task, and are thus exposed to more objects from practiced categories, potentially inducing forgetting due to set-size. Herein I pitted the category-based set size hypothesis against the recognition-induced forgetting hypothesis. To this end, I parametrically manipulated the amount of practice objects received in the recognition-induced forgetting paradigm. If forgetting is due to category-based set size, then the magnitude of forgetting of related objects will increase as the number of practice trials increases. If forgetting is recognition induced, the set size of exemplars from any given category should not be predictive of memory for practiced objects. Consistent with this latter hypothesis, additional practice systematically improved memory for practiced objects, but did not systematically affect forgetting of related objects. These results firmly establish that recognition practice induces forgetting of related memories. Future directions and important real-world applications of using recognition to access our visual memories of previously encountered objects are discussed.
Seckin, Berna; Pekcan, Meryem Kuru; Bostancı, Esra Isci; Inal, Hasan Ali; Cicek, Mahmut Nedim
2016-04-01
The objective of the study was to compare the pregnancy rates in PCOS patients undergoing clomiphene citrate (CC) and intrauterine insemination (IUI) treatment with different leading follicular sizes. A total of 358 infertile women with PCOS who underwent 563 clomiphene citrate and IUI treatment cycles were included in this prospective study. Treatment cycles were divided into three groups according to leading follicular size on the day of hCG administration: Group I: follicular size 17-18 mm (n = 177), Group II: 19-22 mm (n = 321), and Group III : >22 mm (n = 65). Pregnancy rates were evaluated. Treatment outcomes of the groups were further analyzed related to endometrial thickness measurement on the day of hCG. For this purpose, cycles were placed into three subgroups as follows: endometrial thickness <7, 8-9, and >9 mm. There was no statistically significant difference in clinical pregnancy rate per cycle between the groups (8.5, 10, and 9.2 % for Group I, II, and III, respectively, p = 0.86). In further analyses related to endometrial thickness, no significant difference was also found in pregnancy rate among the groups. This results suggest that pregnancy rate is not related to leading follicle size on the day of hCG administration in PCOS patients treated with CC and IUI. In addition, pregnancy rate in women with different follicular sizes is not influenced by the endometrial thickness.
Automatic feature-based grouping during multiple object tracking.
Erlikhman, Gennady; Keane, Brian P; Mettler, Everett; Horowitz, Todd S; Kellman, Philip J
2013-12-01
Contour interpolation automatically binds targets with distractors to impair multiple object tracking (Keane, Mettler, Tsoi, & Kellman, 2011). Is interpolation special in this regard or can other features produce the same effect? To address this question, we examined the influence of eight features on tracking: color, contrast polarity, orientation, size, shape, depth, interpolation, and a combination (shape, color, size). In each case, subjects tracked 4 of 8 objects that began as undifferentiated shapes, changed features as motion began (to enable grouping), and returned to their undifferentiated states before halting. We found that intertarget grouping improved performance for all feature types except orientation and interpolation (Experiment 1 and Experiment 2). Most importantly, target-distractor grouping impaired performance for color, size, shape, combination, and interpolation. The impairments were, at times, large (>15% decrement in accuracy) and occurred relative to a homogeneous condition in which all objects had the same features at each moment of a trial (Experiment 2), and relative to a "diversity" condition in which targets and distractors had different features at each moment (Experiment 3). We conclude that feature-based grouping occurs for a variety of features besides interpolation, even when irrelevant to task instructions and contrary to the task demands, suggesting that interpolation is not unique in promoting automatic grouping in tracking tasks. Our results also imply that various kinds of features are encoded automatically and in parallel during tracking.
Assessing trade-offs in large marine protected areas.
Davies, Tammy E; Epstein, Graham; Aguilera, Stacy E; Brooks, Cassandra M; Cox, Michael; Evans, Louisa S; Maxwell, Sara M; Nenadovic, Mateja; Ban, Natalie C
2018-01-01
Large marine protected areas (LMPAs) are increasingly being established and have a high profile in marine conservation. LMPAs are expected to achieve multiple objectives, and because of their size are postulated to avoid trade-offs that are common in smaller MPAs. However, evaluations across multiple outcomes are lacking. We used a systematic approach to code several social and ecological outcomes of 12 LMPAs. We found evidence of three types of trade-offs: trade-offs between different ecological resources (supply trade-offs); trade-offs between ecological resource conditions and the well-being of resource users (supply-demand trade-offs); and trade-offs between the well-being outcomes of different resource users (demand trade-offs). We also found several divergent outcomes that were attributed to influences beyond the scope of the LMPA. We suggest that despite their size, trade-offs can develop in LMPAs and should be considered in planning and design. LMPAs may improve their performance across multiple social and ecological objectives if integrated with larger-scale conservation efforts.
Assessing trade-offs in large marine protected areas
Aguilera, Stacy E.; Brooks, Cassandra M.; Cox, Michael; Evans, Louisa S.; Maxwell, Sara M.; Nenadovic, Mateja
2018-01-01
Large marine protected areas (LMPAs) are increasingly being established and have a high profile in marine conservation. LMPAs are expected to achieve multiple objectives, and because of their size are postulated to avoid trade-offs that are common in smaller MPAs. However, evaluations across multiple outcomes are lacking. We used a systematic approach to code several social and ecological outcomes of 12 LMPAs. We found evidence of three types of trade-offs: trade-offs between different ecological resources (supply trade-offs); trade-offs between ecological resource conditions and the well-being of resource users (supply-demand trade-offs); and trade-offs between the well-being outcomes of different resource users (demand trade-offs). We also found several divergent outcomes that were attributed to influences beyond the scope of the LMPA. We suggest that despite their size, trade-offs can develop in LMPAs and should be considered in planning and design. LMPAs may improve their performance across multiple social and ecological objectives if integrated with larger-scale conservation efforts. PMID:29668750
Avian Monitoring and Risk Assessment at the San Gorgonio Wind Resource Area
DOE Office of Scientific and Technical Information (OSTI.GOV)
Anderson, R.; Tom, J.; Neumann, N.
2005-08-01
The primary objective of this study at the San Gorgonio Wind Resource Area was to estimate and compare bird utilization, fatality rates, and the risk index among factors including bird taxonomic groups, wind turbine and reference areas, wind turbine sizes and types, and geographic locations. The key questions addressed to meet this objective include: (1) Are there any differences in the level of bird activity, called ''utilization rate'' or ''use'', with the operating wind plant and within the surrounding undeveloped areas (reference area)?; (2) Are there any differences in the rate of bird fatalities (or avian fatality) within the operatingmore » wind plant or the surrounding undeveloped areas (reference area)?; (3) Does bird use, fatality rates, or bird risk index vary according to the geographic location, type and size of wind turbine, and/or type of bird within the operating wind plant and surrounding undeveloped areas (reference area)?; and (4) How do raptor fatality rates at San Gorgonio compare to other wind projects with comparable data?« less
A novel mechanical antrum model for the prediction of the gastroretentive potential of dosage forms.
Neumann, Marco; Schneider, Felix; Koziolek, Mirko; Garbacz, Grzegorz; Weitschies, Werner
2017-09-15
The development of gastroretentive dosage forms can be significantly enhanced by the reliable estimation of gastroretentive properties in vitro. In this context, it is mandatory to consider the propulsive contraction waves that occur in the antral region of the stomach, since they are regarded as the major physiological hurdle to overcome. Therefore, the aim of this study was to develop an in vitro model that allowed the evaluation of the gastroretentive potential of objects with different properties (e.g. size, shape and elasticity). The model enabled a realistic simulation of the human antrum and occurring contraction waves. We could demonstrate that larger objects made of elastic polyurethane foam were more rapidly emptied by the model than smaller objects having the same shape. Compared to this, rigid as well as slippery objects showed decreased gastroretentive properties. In contrast, a self-formed trichobezoar - an indigestible object known to remain in the stomach - showed the highest gastroretentive potential. We suggest that the gastroretentive potential of objects of a certain size increases if they exhibit compressible and elastic properties along with certain dimensions. The data showed that the development of novel gastroretentive dosage forms may be facilitated with the aid of the mechanical antrum model. Copyright © 2017 Elsevier B.V. All rights reserved.
Illusions of having small or large invisible bodies influence visual perception of object size
van der Hoort, Björn; Ehrsson, H. Henrik
2016-01-01
The size of our body influences the perceived size of the world so that objects appear larger to children than to adults. The mechanisms underlying this effect remain unclear. It has been difficult to dissociate visual rescaling of the external environment based on an individual’s visible body from visual rescaling based on a central multisensory body representation. To differentiate these potential causal mechanisms, we manipulated body representation without a visible body by taking advantage of recent developments in body representation research. Participants experienced the illusion of having a small or large invisible body while object-size perception was tested. Our findings show that the perceived size of test-objects was determined by the size of the invisible body (inverse relation), and by the strength of the invisible body illusion. These findings demonstrate how central body representation directly influences visual size perception, without the need for a visible body, by rescaling the spatial representation of the environment. PMID:27708344
The Case against Secondary Task Analyses of Mental Workload.
1980-01-10
different attributes of one object (e.g., its color, form and size) than one attribute of three objects (e.g., red, green and blue or square, circle and...RED printed in colored ink, e.g. green . The subjecc is instructed to report the ink color, ignoring the color word. This is quite difficult for most...Directions in Cognitive Psycholoz. London: Routledge & Kegan Paul (in press). Baddeley, A. D. The capacity for generating information by randomization
NASA Astrophysics Data System (ADS)
Bychkov, P. S.; Chentsov, A. V.; Kozintsev, V. M.; Popov, A. L.
2018-04-01
A calculation-experimental technique is developed for identification of the shrinkage stresses generated in objects after their additive manufacturing by layer-by-layer photopolymerization. The technique is based on the analysis of shrinkage deformations at bending occurring in a series of samples in the form of plates-stripes with identical sizes, but with different time of polymerization which is predetermined during their production on the 3D printer.
Efficient 3D geometric and Zernike moments computation from unstructured surface meshes.
Pozo, José María; Villa-Uriol, Maria-Cruz; Frangi, Alejandro F
2011-03-01
This paper introduces and evaluates a fast exact algorithm and a series of faster approximate algorithms for the computation of 3D geometric moments from an unstructured surface mesh of triangles. Being based on the object surface reduces the computational complexity of these algorithms with respect to volumetric grid-based algorithms. In contrast, it can only be applied for the computation of geometric moments of homogeneous objects. This advantage and restriction is shared with other proposed algorithms based on the object boundary. The proposed exact algorithm reduces the computational complexity for computing geometric moments up to order N with respect to previously proposed exact algorithms, from N(9) to N(6). The approximate series algorithm appears as a power series on the rate between triangle size and object size, which can be truncated at any desired degree. The higher the number and quality of the triangles, the better the approximation. This approximate algorithm reduces the computational complexity to N(3). In addition, the paper introduces a fast algorithm for the computation of 3D Zernike moments from the computed geometric moments, with a computational complexity N(4), while the previously proposed algorithm is of order N(6). The error introduced by the proposed approximate algorithms is evaluated in different shapes and the cost-benefit ratio in terms of error, and computational time is analyzed for different moment orders.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Stern, S. A.; Schindhelm, E.; Cunningham, N. J., E-mail: astern@swri.edu
We observed the 2600-3200 Å (hereafter, mid-UV) reflectance of two Kuiper Belt Objects (KBOs), two KBO satellites, and a Centaur, using the Hubble Space Telescope (HST) Cosmic Origins Spectrograph (COS). Other than measurements of the Pluto system, these constitute the first UV measurements obtained of KBOs, and KBO satellites, and new HST UV measurements of the Centaur 2060 Chiron. We find significant differences among these objects, constrain the sizes and densities of Haumea's satellites, and report the detection of a possible spectral absorption band in Haumea's spectrum near 3050 Å. Comparisons of these objects to previously published UV reflectance measurementsmore » of Pluto and Charon are also made here.« less
Erwin; Gunanti; Handharyani, Ekowati; Noviana, Deni
2016-05-01
The success of a skin graft in a cat is highly dependent on the granulation formed by the base of recipient bed. Granulation by the base of recipient bed will form after several days after injury. This research aimed to observe subjective and objective profile of skin graft recovery on forelimb of cats with different periods of donor skin placement. Nine male Indonesian local cats aged 1-2 years old, weighing 3-4 kg were divided into three groups. The first surgery for creating defect wound of 2 cm×2 cm in size was performed in the whole group. The wound was left for several days with the respective interval for each group, respectively: Group I (for 2 days), Group II (for 4 days), and Group III (for 6 days). In the whole group, the second surgery was done by the harvesting skin of thoracic area which then applied on recipient bed of respective groups. The donor skin on Group II was accepted faster compared to Group I and Group III. The donor skin did not show color differences compared to surrounding skin, painless, bright red in bleeding test had faster both hair growth and drug absorption. Test toward the size of donor skin and the effect of drugs did not show a significant difference between each group. The observe subjective and objective profile of skin graft recovery on forelimb of cats on Group II were accepted faster compared to Group I and III.
System of technical vision for autonomous unmanned aerial vehicles
NASA Astrophysics Data System (ADS)
Bondarchuk, A. S.
2018-05-01
This paper is devoted to the implementation of image recognition algorithm using the LabVIEW software. The created virtual instrument is designed to detect the objects on the frames from the camera mounted on the UAV. The trained classifier is invariant to changes in rotation, as well as to small changes in the camera's viewing angle. Finding objects in the image using particle analysis, allows you to classify regions of different sizes. This method allows the system of technical vision to more accurately determine the location of the objects of interest and their movement relative to the camera.
van der Waals interactions between nanostructures: Some analytic results from series expansions
NASA Astrophysics Data System (ADS)
Stedman, T.; Drosdoff, D.; Woods, L. M.
2014-01-01
The van der Waals force between objects of nontrivial geometries is considered. A technique based on a perturbation series approach is formulated in the dilute limit. We show that the dielectric response and object size can be decoupled and dominant contributions in terms of object separations can be obtained. This is a powerful method, which enables straightforward calculations of the interaction for different geometries. Our results for planar structures, such as thin sheets, infinitely long ribbons, and ribbons with finite dimensions, may be applicable for nanostructured devices where the van der Waals interaction plays an important role.
Sountsov, Pavel; Santucci, David M; Lisman, John E
2011-01-01
Visual object recognition occurs easily despite differences in position, size, and rotation of the object, but the neural mechanisms responsible for this invariance are not known. We have found a set of transforms that achieve invariance in a neurally plausible way. We find that a transform based on local spatial frequency analysis of oriented segments and on logarithmic mapping, when applied twice in an iterative fashion, produces an output image that is unique to the object and that remains constant as the input image is shifted, scaled, or rotated.
Sountsov, Pavel; Santucci, David M.; Lisman, John E.
2011-01-01
Visual object recognition occurs easily despite differences in position, size, and rotation of the object, but the neural mechanisms responsible for this invariance are not known. We have found a set of transforms that achieve invariance in a neurally plausible way. We find that a transform based on local spatial frequency analysis of oriented segments and on logarithmic mapping, when applied twice in an iterative fashion, produces an output image that is unique to the object and that remains constant as the input image is shifted, scaled, or rotated. PMID:22125522
3D Surface Reconstruction for Lower Limb Prosthetic Model using Radon Transform
NASA Astrophysics Data System (ADS)
Sobani, S. S. Mohd; Mahmood, N. H.; Zakaria, N. A.; Razak, M. A. Abdul
2018-03-01
This paper describes the idea to realize three-dimensional surfaces of objects with cylinder-based shapes where the techniques adopted and the strategy developed for a non-rigid three-dimensional surface reconstruction of an object from uncalibrated two-dimensional image sequences using multiple-view digital camera and turntable setup. The surface of an object is reconstructed based on the concept of tomography with the aid of performing several digital image processing algorithms on the two-dimensional images captured by a digital camera in thirty-six different projections and the three-dimensional structure of the surface is analysed. Four different objects are used as experimental models in the reconstructions and each object is placed on a manually rotated turntable. The results shown that the proposed method has successfully reconstruct the three-dimensional surface of the objects and practicable. The shape and size of the reconstructed three-dimensional objects are recognizable and distinguishable. The reconstructions of objects involved in the test are strengthened with the analysis where the maximum percent error obtained from the computation is approximately 1.4 % for the height whilst 4.0%, 4.79% and 4.7% for the diameters at three specific heights of the objects.
Göhler, Daniel; Wessely, Benno; Stintz, Michael; Lazzerini, Giovanni Mattia; Yacoot, Andrew
2017-01-01
Dimensional measurements on nano-objects by atomic force microscopy (AFM) require samples of safely fixed and well individualized particles with a suitable surface-specific particle number on flat and clean substrates. Several known and proven particle preparation methods, i.e., membrane filtration, drying, rinsing, dip coating as well as electrostatic and thermal precipitation, were performed by means of scanning electron microscopy to examine their suitability for preparing samples for dimensional AFM measurements. Different suspensions of nano-objects (with varying material, size and shape) stabilized in aqueous solutions were prepared therefore on different flat substrates. The drop-drying method was found to be the most suitable one for the analysed suspensions, because it does not require expensive dedicated equipment and led to a uniform local distribution of individualized nano-objects. Traceable AFM measurements based on Si and SiO2 coated substrates confirmed the suitability of this technique. PMID:28904839
Fiala, Petra; Göhler, Daniel; Wessely, Benno; Stintz, Michael; Lazzerini, Giovanni Mattia; Yacoot, Andrew
2017-01-01
Dimensional measurements on nano-objects by atomic force microscopy (AFM) require samples of safely fixed and well individualized particles with a suitable surface-specific particle number on flat and clean substrates. Several known and proven particle preparation methods, i.e., membrane filtration, drying, rinsing, dip coating as well as electrostatic and thermal precipitation, were performed by means of scanning electron microscopy to examine their suitability for preparing samples for dimensional AFM measurements. Different suspensions of nano-objects (with varying material, size and shape) stabilized in aqueous solutions were prepared therefore on different flat substrates. The drop-drying method was found to be the most suitable one for the analysed suspensions, because it does not require expensive dedicated equipment and led to a uniform local distribution of individualized nano-objects. Traceable AFM measurements based on Si and SiO 2 coated substrates confirmed the suitability of this technique.
Molar crown and root size relationship in anthropoid primates.
Kupczik, Kornelius; Olejniczak, Anthony J; Skinner, Matthew M; Hublin, Jean-Jacques
2009-01-01
Mandibular corpus form is thought to reflect masticatory function and the size of the dentition, but there is no universal association between crown dimensions and corpus size across anthropoids. Previous research was based on the assumption that crown size is an appropriate proxy for overall tooth size, but this hypothesis remains largely untested. This study assesses the relationship between the volume and surface area of molar crowns and roots by examining two main hypotheses: (1) crown size correlates significantly with root size, and (2) the proportion of root-to-crown surface area is related to dietary proclivity. Permanent M2s (n=58) representing 19 anthropoid species were CT scanned and the volume and surface area of the crown and root were measured. Interspecific correlation and regression analyses reveal significant isometric relationships between crown and root volume and a positive allometric relationship between root and crown surface area (i.e. as crown surface area increases, root surface area becomes disproportionately greater). Intraspecifically, crown and root surface area correlate significantly in some species where such analyses were possible. In general, hard object feeders exhibit relatively larger root surface area per unit crown surface area compared to soft and tough object feeders. The results also show that despite differences in food specialization closely related species have similar root-to-crown surface area proportions, thus indicating a strong phylogenetic influence. Since it is possible that, at least in some species, crown and root size vary independently, future studies should elucidate the relationship between tooth root size and mandible form. Copyright (c) 2009 S. Karger AG, Basel.
Sex differences in a human analogue of the Radial Arm Maze: the "17-Box Maze Test".
Rahman, Qazi; Abrahams, Sharon; Jussab, Fardin
2005-08-01
This study investigated sex differences in spatial memory using a human analogue of the Radial Arm Maze: a revision on the Nine Box Maze originally developed by called the 17-Box Maze Test herein. The task encourages allocentric spatial processing, dissociates object from spatial memory, and incorporates a within-participants design to provide measures of location and object, working and reference memory. Healthy adult males and females (26 per group) were administered the 17-Box Maze Test, as well as mental rotation and a verbal IQ test. Females made significantly fewer errors on this task than males. However, post hoc analysis revealed that the significant sex difference was specific to object, rather than location, memory measures. These were medium to large effect sizes. The findings raise the issue of task- and component-specific sexual dimorphism in cognitive mapping.
Non-invasive imaging methods applied to neo- and paleo-ontological cephalopod research
NASA Astrophysics Data System (ADS)
Hoffmann, R.; Schultz, J. A.; Schellhorn, R.; Rybacki, E.; Keupp, H.; Gerden, S. R.; Lemanis, R.; Zachow, S.
2014-05-01
Several non-invasive methods are common practice in natural sciences today. Here we present how they can be applied and contribute to current topics in cephalopod (paleo-) biology. Different methods will be compared in terms of time necessary to acquire the data, amount of data, accuracy/resolution, minimum/maximum size of objects that can be studied, the degree of post-processing needed and availability. The main application of the methods is seen in morphometry and volumetry of cephalopod shells. In particular we present a method for precise buoyancy calculation. Therefore, cephalopod shells were scanned together with different reference bodies, an approach developed in medical sciences. It is necessary to know the volume of the reference bodies, which should have similar absorption properties like the object of interest. Exact volumes can be obtained from surface scanning. Depending on the dimensions of the study object different computed tomography techniques were applied.
Taking a Hands-On Approach: Apparent Grasping Ability Scales the Perception of Object Size
ERIC Educational Resources Information Center
Linkenauger, Sally A.; Witt, Jessica K.; Proffitt, Dennis R.
2011-01-01
We examined whether the apparent size of an object is scaled to the morphology of the relevant body part with which one intends to act on it. To be specific, we tested if the visually perceived size of graspable objects is scaled to the extent of apparent grasping ability for the individual. Previous research has shown that right-handed…
NASA Astrophysics Data System (ADS)
Krauß, T.
2014-11-01
The focal plane assembly of most pushbroom scanner satellites is built up in a way that different multispectral or multispectral and panchromatic bands are not all acquired exactly at the same time. This effect is due to offsets of some millimeters of the CCD-lines in the focal plane. Exploiting this special configuration allows the detection of objects moving during this small time span. In this paper we present a method for automatic detection and extraction of moving objects - mainly traffic - from single very high resolution optical satellite imagery of different sensors. The sensors investigated are WorldView-2, RapidEye, Pléiades and also the new SkyBox satellites. Different sensors require different approaches for detecting moving objects. Since the objects are mapped on different positions only in different spectral bands also the change of spectral properties have to be taken into account. In case the main distance in the focal plane is between the multispectral and the panchromatic CCD-line like for Pléiades an approach for weighted integration to receive mostly identical images is investigated. Other approaches for RapidEye and WorldView-2 are also shown. From these intermediate bands difference images are calculated and a method for detecting the moving objects from these difference images is proposed. Based on these presented methods images from different sensors are processed and the results are assessed for detection quality - how many moving objects can be detected, how many are missed - and accuracy - how accurate is the derived speed and size of the objects. Finally the results are discussed and an outlook for possible improvements towards operational processing is presented.
NASA Astrophysics Data System (ADS)
Menu, J.; van Boekel, R.; Henning, Th.; Leinert, Ch.; Waelkens, C.; Waters, L. B. F. M.
2015-09-01
Context. The disks around Herbig Ae/Be stars are commonly divided into group I and group II based on their far-infrared spectral energy distribution, and the common interpretation for that is flared and flat disks. Our understanding of the evolution of these disks is rapidly changing. Recent observations suggest that many flaring disks have gaps, whereas flat disks are thought to be gapless. Aims: The different groups of objects can be expected to have different structural signatures in high-angular-resolution data, related to gaps, dust settling, and flaring. We aim to use such data to gain new insight into disk structure and evolution. Methods: Over the past 10 years, the MIDI instrument on the Very Large Telescope Interferometer has collected observations of several tens of protoplanetary disks. We modeled the large set of observations with simple geometric models and compared the characteristic sizes among the different objects. A population of radiative-transfer models was synthesized for interpreting the mid-infrared signatures. Results: Objects with similar luminosities show very different disk sizes in the mid-infrared. This may point to an intrinsic diversity or could also hint at different evolutionary stages of the disks. Restricting this to the young objects of intermediate mass, we confirm that most group I disks are in agreement with being transitional (i.e., they have gaps). We find that several group II objects have mid-infrared sizes and colors that overlap with sources classified as group I, transition disks. This suggests that these sources have gaps, which has been demonstrated for a subset of them. This may point to an intermediate population between gapless and transition disks. Conclusions: Flat disks with gaps are most likely descendants of flat disks without gaps. Potentially related to the formation of massive bodies, gaps may therefore even develop in disks in a far stage of grain growth and settling. The evolutionary implications of this new population could be twofold. Either gapped flat disks form a separate population of evolved disks or some of them may evolve further into flaring disks with large gaps. The latter transformation may be governed by the interaction with a massive planet, carving a large gap and dynamically exciting the grain population in the disk. Appendices A and B are available in electronic form at http://www.aanda.org
Applications of dewetting in micro and nanotechnology.
Gentili, Denis; Foschi, Giulia; Valle, Francesco; Cavallini, Massimiliano; Biscarini, Fabio
2012-06-21
Dewetting is a spontaneous phenomenon where a thin film on a surface ruptures into an ensemble of separated objects, like droplets, stripes, and pillars. Spatial correlations with characteristic distance and object size emerge spontaneously across the whole dewetted area, leading to regular motifs with long-range order. Characteristic length scales depend on film thickness, which is a convenient and robust technological parameter. Dewetting is therefore an attractive paradigm for organizing a material into structures of well-defined micro- or nanometre-size, precisely positioned on a surface, thus avoiding lithographical processes. This tutorial review introduces the reader to the physical-chemical basis of dewetting, shows how the dewetting process can be applied to different functional materials with relevance in technological applications, and highlights the possible strategies to control the length scales of the dewetting process.
EPR investigation of UV light effect on calcium carbonate powders with different grain sizes.
Kabacińska, Zuzanna; Krzyminiewski, Ryszard; Dobosz, Bernadeta
2014-06-01
This study is based on investigation of calcium carbonate powders with different grain sizes exposed to UV light. Calcium carbonate is widely used in many branches of industry, e.g. as a filler for polymer materials; therefore, knowing its properties, among them also its reaction to UV light, is essential. Samples of powdered calcium carbonate with average grain sizes of 69 and 300 nm and 2.1, 6, 16, 25 µm were used in this investigation. Measurements were performed at room temperature using EPR X-band spectrometer, and they have shown the additional signals induced by the light from Hg lamp. The effect of annealing of the micro-grain samples was also studied. The spectra of four micro-grain samples after irradiation are similar, but there are differences between them and the other two powders, which could be related to the different sizes of their grains. Further studies based on these preliminary results may prove useful in research of photodegradation of CaCO3-filled materials, as well as helpful in increasing the accuracy of dating of archaeological and geological objects. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Simulations of Liners and Test Objects for a New Atlas Advanced Radiography Source
DOE Office of Scientific and Technical Information (OSTI.GOV)
D. V. Morgan; S. Iversen; R. A. Hilko
2002-06-01
The Advanced Radiographic Source (ARS) will improve the data significantly due to its smaller source width. Because of the enhanced ARS output, larger source-to-object distances are a reality. The harder ARS source will allow radiography of thick high-Z targets. The five different spectral simulations resulted in similar imaging detector weighted transmission. This work used a limited set of test objects and imaging detectors. Other test objects and imaging detectors could possibly change the MVp-sensitivity result. The effect of material motion blur must be considered for the ARS due to the expected smaller X-ray source size. This study supports the originalmore » 1.5-MVp value.« less
A review of the findings and theories on surface size effects on visual attention
Peschel, Anne O.; Orquin, Jacob L.
2013-01-01
That surface size has an impact on attention has been well-known in advertising research for almost a century; however, theoretical accounts of this effect have been sparse. To address this issue, we review studies on surface size effects on eye movements in this paper. While most studies find that large objects are more likely to be fixated, receive more fixations, and are fixated faster than small objects, a comprehensive explanation of this effect is still lacking. To bridge the theoretical gap, we relate the findings from this review to three theories of surface size effects suggested in the literature: a linear model based on the assumption of random fixations (Lohse, 1997), a theory of surface size as visual saliency (Pieters etal., 2007), and a theory based on competition for attention (CA; Janiszewski, 1998). We furthermore suggest a fourth model – demand for attention – which we derive from the theory of CA by revising the underlying model assumptions. In order to test the models against each other, we reanalyze data from an eye tracking study investigating surface size and saliency effects on attention. The reanalysis revealed little support for the first three theories while the demand for attention model showed a much better alignment with the data. We conclude that surface size effects may best be explained as an increase in object signal strength which depends on object size, number of objects in the visual scene, and object distance to the center of the scene. Our findings suggest that advertisers should take into account how objects in the visual scene interact in order to optimize attention to, for instance, brands and logos. PMID:24367343
A review of the findings and theories on surface size effects on visual attention.
Peschel, Anne O; Orquin, Jacob L
2013-12-09
That surface size has an impact on attention has been well-known in advertising research for almost a century; however, theoretical accounts of this effect have been sparse. To address this issue, we review studies on surface size effects on eye movements in this paper. While most studies find that large objects are more likely to be fixated, receive more fixations, and are fixated faster than small objects, a comprehensive explanation of this effect is still lacking. To bridge the theoretical gap, we relate the findings from this review to three theories of surface size effects suggested in the literature: a linear model based on the assumption of random fixations (Lohse, 1997), a theory of surface size as visual saliency (Pieters etal., 2007), and a theory based on competition for attention (CA; Janiszewski, 1998). We furthermore suggest a fourth model - demand for attention - which we derive from the theory of CA by revising the underlying model assumptions. In order to test the models against each other, we reanalyze data from an eye tracking study investigating surface size and saliency effects on attention. The reanalysis revealed little support for the first three theories while the demand for attention model showed a much better alignment with the data. We conclude that surface size effects may best be explained as an increase in object signal strength which depends on object size, number of objects in the visual scene, and object distance to the center of the scene. Our findings suggest that advertisers should take into account how objects in the visual scene interact in order to optimize attention to, for instance, brands and logos.
NASA Technical Reports Server (NTRS)
Hejduk, M. D.; Cowardin, H. M.; Stansbery, Eugene G.
2012-01-01
In performing debris surveys of deep-space orbital regions, the considerable volume of the area to be surveyed and the increased orbital altitude suggest optical telescopes as the most efficient survey instruments; but to proceed this way, methodologies for debris object size estimation using only optical tracking and photometric information are needed. Basic photometry theory indicates that size estimation should be possible if satellite albedo and shape are known. One method for estimating albedo is to try to determine the object's material type photometrically, as one can determine the albedos of common satellite materials in the laboratory. Examination of laboratory filter photometry (using Johnson BVRI filters) on a set of satellite material samples indicates that most material types can be separated at the 1-sigma level via B-R versus R-I color differences with a relatively small amount of required resampling, and objects that remain ambiguous can be resolved by B-R versus B-V color differences and solar radiation pressure differences. To estimate shape, a technique advanced by Hall et al. [1], based on phase-brightness density curves and not requiring any a priori knowledge of attitude, has been modified slightly to try to make it more resistant to the specular characteristics of different materials and to reduce the number of samples necessary to make robust shape determinations. Working from a gallery of idealized debris shapes, the modified technique identifies most shapes within this gallery correctly, also with a relatively small amount of resampling. These results are, of course, based on relatively small laboratory investigations and simulated data, and expanded laboratory experimentation and further investigation with in situ survey measurements will be required in order to assess their actual efficacy under survey conditions; but these techniques show sufficient promise to justify this next level of analysis.
Probing the reaching-grasping network in humans through multivoxel pattern decoding.
Di Bono, Maria Grazia; Begliomini, Chiara; Castiello, Umberto; Zorzi, Marco
2015-11-01
The quest for a putative human homolog of the reaching-grasping network identified in monkeys has been the focus of many neuropsychological and neuroimaging studies in recent years. These studies have shown that the network underlying reaching-only and reach-to-grasp movements includes the superior parieto-occipital cortex (SPOC), the anterior part of the human intraparietal sulcus (hAIP), the ventral and the dorsal portion of the premotor cortex, and the primary motor cortex (M1). Recent evidence for a wider frontoparietal network coding for different aspects of reaching-only and reach-to-grasp actions calls for a more fine-grained assessment of the reaching-grasping network in humans by exploiting pattern decoding methods (multivoxel pattern analysis--MVPA). Here, we used MPVA on functional magnetic resonance imaging (fMRI) data to assess whether regions of the frontoparietal network discriminate between reaching-only and reach-to-grasp actions, natural and constrained grasping, different grasp types, and object sizes. Participants were required to perform either reaching-only movements or two reach-to-grasp types (precision or whole hand grasp) upon spherical objects of different sizes. Multivoxel pattern analysis highlighted that, independently from the object size, all the selected regions of both hemispheres contribute in coding for grasp type, with the exception of SPOC and the right hAIP. Consistent with recent neurophysiological findings on monkeys, there was no evidence for a clear-cut distinction between a dorsomedial and a dorsolateral pathway that would be specialized for reaching-only and reach-to-grasp actions, respectively. Nevertheless, the comparison of decoding accuracy across brain areas highlighted their different contributions to reaching-only and grasping actions. Altogether, our findings enrich the current knowledge regarding the functional role of key brain areas involved in the cortical control of reaching-only and reach-to-grasp actions in humans, by revealing novel fine-grained distinctions among action types within a wide frontoparietal network.
Orbital debris environment for spacecraft in low earth orbit
NASA Technical Reports Server (NTRS)
Kessler, Donald J.
1990-01-01
Modeling and measurement results used in formulating an environment model that can be used for the engineering design of spacecraft are reviewed. Earth-based and space-based sensors are analyzed and it is noted that the effects of satellite breakups can be modeled to predict a uncatalogued population, if the nature of the breakup is understood. It is observed that the telescopic data indicate that the current model is too low for sizes slightly larger than 10 cm, and may be too low for sizes between 2 cm and 10 cm, while there is an uncertainty in the current development, especially for sizes smaller than 10 cm, and at altitudes different from 500 km. Projections for the catastrophic collision rate for different growth conditions are made, emphasizing that the rate of growth of fragments will be twice the rate of intact objects.
Tuning Aerosol Particle Size Distribution of Metered Dose Inhalers Using Cosolvents and Surfactants
Saleem, Imran Y.; Smyth, Hugh D. C.
2013-01-01
Objectives. The purpose of these studies was to understand the influence of cosolvent and surfactant contributions to particle size distributions emitted from solution metered dose inhalers (pMDIs) based on the propellant HFA 227. Methods. Two sets of formulations were prepared: (a) pMDIs-HFA 227 containing cosolvent (5–15% w/w ethanol) with constant surfactant (pluronic) concentration and (b) pMDIs-HFA 227 containing surfactant (0–5.45% w/w pluronic) with constant cosolvent concentration. Particle size distributions emitted from these pMDIs were analyzed using aerodynamic characterization (inertial impaction) and laser diffraction methods. Results. Both cosolvent and surfactant concentrations were positively correlated with median particle sizes; that is, drug particle size increased with increasing ethanol and pluronic concentrations. However, evaluation of particle size distributions showed that cosolvent caused reduction in the fine particle mode magnitude while the surfactant caused a shift in the mode position. These findings highlight the different mechanisms by which these components influence droplet formation and demonstrate the ability to utilize the different effects in formulations of pMDI-HFA 227 for independently modulating particle sizes in the respirable region. Conclusion. Potentially, the formulation design window generated using these excipients in combination could be used to match the particle size output of reformulated products to preexisting pMDI products. PMID:23984381
Front-Presented Looming Sound Selectively Alters the Perceived Size of a Visual Looming Object.
Yamasaki, Daiki; Miyoshi, Kiyofumi; Altmann, Christian F; Ashida, Hiroshi
2018-07-01
In spite of accumulating evidence for the spatial rule governing cross-modal interaction according to the spatial consistency of stimuli, it is still unclear whether 3D spatial consistency (i.e., front/rear of the body) of stimuli also regulates audiovisual interaction. We investigated how sounds with increasing/decreasing intensity (looming/receding sound) presented from the front and rear space of the body impact the size perception of a dynamic visual object. Participants performed a size-matching task (Experiments 1 and 2) and a size adjustment task (Experiment 3) of visual stimuli with increasing/decreasing diameter, while being exposed to a front- or rear-presented sound with increasing/decreasing intensity. Throughout these experiments, we demonstrated that only the front-presented looming sound caused overestimation of the spatially consistent looming visual stimulus in size, but not of the spatially inconsistent and the receding visual stimulus. The receding sound had no significant effect on vision. Our results revealed that looming sound alters dynamic visual size perception depending on the consistency in the approaching quality and the front-rear spatial location of audiovisual stimuli, suggesting that the human brain differently processes audiovisual inputs based on their 3D spatial consistency. This selective interaction between looming signals should contribute to faster detection of approaching threats. Our findings extend the spatial rule governing audiovisual interaction into 3D space.
Crijns, C P; Van Bree, H J; Broeckx, B J G; Schauvliege, S; Van Loon, G; Martens, A; Vanderperren, K; Dingemanse, W B; Gielen, I M
2017-06-01
The objective of this study was to examine the influence of the size, age and sex of the horse on the size of the pituitary gland and determine the possibility of using the pituitary gland height-to-brain area ratio (P:B ratio) to allow comparison of different sized and aged horses. Thirty-two horses without pituitary pars inter-media dysfunction that underwent a contrast-enhanced computed tomographic (CT) examination were included in a cross-sectional study. On the CT images, the pituitary gland height was measured and the P:B ratio was calculated. These measurements were correlated to the size, age and sex of the horses. The pituitary gland height was significantly associated with the size (P < 0.001) and the age (P < 0.001), but not with the sex (P = 0.40), of the horses. No significant association was found between the P:B ratio and the size (P = 0.25), the age (P = 0.06) or the sex (P = 0.25) of the horses. In conclusion, the pituitary gland size varies between different sized and aged horses. The use of the P:B ratio is a valuable metric for making comparisons between the pituitary glands of these horses. © 2017 Blackwell Verlag GmbH.
Distribution of the near-earth objects
NASA Astrophysics Data System (ADS)
Emel'Yanenko, V. V.; Naroenkov, S. A.; Shustov, B. M.
2011-12-01
This paper analyzes the distribution of the orbits of near-Earth minor bodies from the data on more than 7500 objects. The distribution of large near-Earth objects (NEOs) with absolute magnitudes of H < 18 is generally consistent with the earlier predictions (Bottke et al., 2002; Stuart, 2003), although we have revealed a previously undetected maximum in the distribution of perihelion distances q near q = 0.5 AU. The study of the orbital distribution for the entire sample of all detected objects has found new significant features. In particular, the distribution of perihelion longitudes seriously deviates from a homogeneous pattern; its variations are roughly 40% of its mean value. These deviations cannot be stochastic, which is confirmed by the Kolmogorov-Smirnov test with a more than 0.9999 probability. These features can be explained by the dynamic behavior of the minor bodies related to secular resonances with Jupiter. For the objects with H < 18, the variations in the perihelion longitude distribution are not so apparent. By extrapolating the orbital characteristics of the NEOs with H < 18, we have obtained longitudinal, latitudinal, and radial distributions of potentially hazardous objects in a heliocentric ecliptic coordinate frame. The differences in the orbital distributions of objects of different size appear not to be a consequence of observational selection, but could indicate different sources of the NEOs.
An aftereffect of adaptation to mean size
Corbett, Jennifer E.; Wurnitsch, Nicole; Schwartz, Alex; Whitney, David
2013-01-01
The visual system rapidly represents the mean size of sets of objects. Here, we investigated whether mean size is explicitly encoded by the visual system, along a single dimension like texture, numerosity, and other visual dimensions susceptible to adaptation. Observers adapted to two sets of dots with different mean sizes, presented simultaneously in opposite visual fields. After adaptation, two test patches replaced the adapting dot sets, and participants judged which test appeared to have the larger average dot diameter. They generally perceived the test that replaced the smaller mean size adapting set as being larger than the test that replaced the larger adapting set. This differential aftereffect held for single test dots (Experiment 2) and high-pass filtered displays (Experiment 3), and changed systematically as a function of the variance of the adapting dot sets (Experiment 4), providing additional support that mean size is adaptable, and therefore explicitly encoded dimension of visual scenes. PMID:24348083
NASA Astrophysics Data System (ADS)
Yulia, M.; Suhandy, D.
2018-03-01
NIR spectra obtained from spectral data acquisition system contains both chemical information of samples as well as physical information of the samples, such as particle size and bulk density. Several methods have been established for developing calibration models that can compensate for sample physical information variations. One common approach is to include physical information variation in the calibration model both explicitly and implicitly. The objective of this study was to evaluate the feasibility of using explicit method to compensate the influence of different particle size of coffee powder in NIR calibration model performance. A number of 220 coffee powder samples with two different types of coffee (civet and non-civet) and two different particle sizes (212 and 500 µm) were prepared. Spectral data was acquired using NIR spectrometer equipped with an integrating sphere for diffuse reflectance measurement. A discrimination method based on PLS-DA was conducted and the influence of different particle size on the performance of PLS-DA was investigated. In explicit method, we add directly the particle size as predicted variable results in an X block containing only the NIR spectra and a Y block containing the particle size and type of coffee. The explicit inclusion of the particle size into the calibration model is expected to improve the accuracy of type of coffee determination. The result shows that using explicit method the quality of the developed calibration model for type of coffee determination is a little bit superior with coefficient of determination (R2) = 0.99 and root mean square error of cross-validation (RMSECV) = 0.041. The performance of the PLS2 calibration model for type of coffee determination with particle size compensation was quite good and able to predict the type of coffee in two different particle sizes with relatively high R2 pred values. The prediction also resulted in low bias and RMSEP values.
Grasp cueing and joint attention.
Tschentscher, Nadja; Fischer, Martin H
2008-10-01
We studied how two different hand posture cues affect joint attention in normal observers. Visual targets appeared over lateralized objects, with different delays after centrally presented hand postures. Attention was cued by either hand direction or the congruency between hand aperture and object size. Participants pressed a button when they detected a target. Direction cues alone facilitated target detection following short delays but aperture cues alone were ineffective. In contrast, when hand postures combined direction and aperture cues, aperture congruency effects without directional congruency effects emerged and persisted, but only for power grips. These results suggest that parallel parameter specification makes joint attention mechanisms exquisitely sensitive to the timing and content of contextual cues.
On the magnetic polarizability tensor of US coinage
NASA Astrophysics Data System (ADS)
Davidson, John L.; Abdel-Rehim, Omar A.; Hu, Peipei; Marsh, Liam A.; O'Toole, Michael D.; Peyton, Anthony J.
2018-03-01
The magnetic dipole polarizability tensor of a metallic object gives unique information about the size, shape and electromagnetic properties of the object. In this paper, we present a novel method of coin characterization based on the spectroscopic response of the absolute tensor. The experimental measurements are validated using a combination of tests with a small set of bespoke coin surrogates and simulated data. The method is applied to an uncirculated set of US coins. Measured and simulated spectroscopic tensor responses of the coins show significant differences between different coin denominations. The presented results are encouraging as they strongly demonstrate the ability to characterize coins using an absolute tensor approach.
Designing and testing a laser-based vibratory sensor
NASA Astrophysics Data System (ADS)
Nath, G.
2018-04-01
Sensor technology has proved its importance, not only in the range of few-meter applications in different fields, but in micro, nano, atomic and sub-atomic-sized objects. The present work describes the designing of a laser-based vibratory sensor using a He-Ne laser as the signal source. The received characteristics of the signal are mainly the frequency and amplitude of the vibration from which the physical parameters such as energy, power and absorption coefficients of the material are determined, which enables us to provide information of the hidden target or object. This laboratory-designed sensor finds application in different local phenomena as well as laboratory practical activity for students.
Global gray-level thresholding based on object size.
Ranefall, Petter; Wählby, Carolina
2016-04-01
In this article, we propose a fast and robust global gray-level thresholding method based on object size, where the selection of threshold level is based on recall and maximum precision with regard to objects within a given size interval. The method relies on the component tree representation, which can be computed in quasi-linear time. Feature-based segmentation is especially suitable for biomedical microscopy applications where objects often vary in number, but have limited variation in size. We show that for real images of cell nuclei and synthetic data sets mimicking fluorescent spots the proposed method is more robust than all standard global thresholding methods available for microscopy applications in ImageJ and CellProfiler. The proposed method, provided as ImageJ and CellProfiler plugins, is simple to use and the only required input is an interval of the expected object sizes. © 2016 International Society for Advancement of Cytometry. © 2016 International Society for Advancement of Cytometry.
Perceived depth between familiar objects.
DOT National Transportation Integrated Search
1967-08-01
In aviation, size cues are frequently used in a pilot's evaluation of depth or distance. In the study, the hypothesis was examined that the essential factor in the size cue to depth from familiar objects is the perceived size S' per unit of retinal s...
Guo, L-X; Li, J; Zeng, H
2009-11-01
We present an investigation of the electromagnetic scattering from a three-dimensional (3-D) object above a two-dimensional (2-D) randomly rough surface. A Message Passing Interface-based parallel finite-difference time-domain (FDTD) approach is used, and the uniaxial perfectly matched layer (UPML) medium is adopted for truncation of the FDTD lattices, in which the finite-difference equations can be used for the total computation domain by properly choosing the uniaxial parameters. This makes the parallel FDTD algorithm easier to implement. The parallel performance with different number of processors is illustrated for one rough surface realization and shows that the computation time of our parallel FDTD algorithm is dramatically reduced relative to a single-processor implementation. Finally, the composite scattering coefficients versus scattered and azimuthal angle are presented and analyzed for different conditions, including the surface roughness, the dielectric constants, the polarization, and the size of the 3-D object.
Spatial resolution in visual memory.
Ben-Shalom, Asaf; Ganel, Tzvi
2015-04-01
Representations in visual short-term memory are considered to contain relatively elaborated information on object structure. Conversely, representations in earlier stages of the visual hierarchy are thought to be dominated by a sensory-based, feed-forward buildup of information. In four experiments, we compared the spatial resolution of different object properties between two points in time along the processing hierarchy in visual short-term memory. Subjects were asked either to estimate the distance between objects or to estimate the size of one of the objects' features under two experimental conditions, of either a short or a long delay period between the presentation of the target stimulus and the probe. When different objects were referred to, similar spatial resolution was found for the two delay periods, suggesting that initial processing stages are sensitive to object-based properties. Conversely, superior resolution was found for the short, as compared with the long, delay when features were referred to. These findings suggest that initial representations in visual memory are hybrid in that they allow fine-grained resolution for object features alongside normal visual sensitivity to the segregation between objects. The findings are also discussed in reference to the distinction made in earlier studies between visual short-term memory and iconic memory.
Nishimura, T; Doi, K; Fujimoto, H
2015-08-01
Touch-sensitive screen terminals enabling intuitive operation are used as input interfaces in a wide range of fields. Tablet terminals are one of the most common devices with a touch-sensitive screen. They have a feature of good portability, enabling use under various conditions. On the other hand, they require a GUI designed to prevent decrease of usability under various conditions. For example, the angle of fingertip contact with the display changes according to finger posture during operation and how the case is held. When a human fingertip makes contact with an object, the contact area between the fingertip and contact object increases or decreases as the contact angle changes. A touch-sensitive screen detects positions using the change in capacitance of the area touched by the fingertip; hence, differences in contact area between the touch-sensitive screen and fingertip resulting from different forefinger angles during operation could possibly affect operability. However, this effect has never been studied. We therefore conducted an experiment to investigate the relationship between size/spacing and operability, while taking the effect of fingertip contact angle into account. As a result, we have been able to specify the button size and spacing conditions that enable accurate and fast operation regardless of the forefinger contact angle.
NASA Astrophysics Data System (ADS)
Pei, Jun; Liu, Xinbao; Pardalos, Panos M.; Fan, Wenjuan; Wang, Ling; Yang, Shanlin
2016-03-01
Motivated by applications in manufacturing industry, we consider a supply chain scheduling problem, where each job is characterised by non-identical sizes, different release times and unequal processing times. The objective is to minimise the makespan by making batching and sequencing decisions. The problem is formalised as a mixed integer programming model and proved to be strongly NP-hard. Some structural properties are presented for both the general case and a special case. Based on these properties, a lower bound is derived, and a novel two-phase heuristic (TP-H) is developed to solve the problem, which guarantees to obtain a worst case performance ratio of ?. Computational experiments with a set of different sizes of random instances are conducted to evaluate the proposed approach TP-H, which is superior to another two heuristics proposed in the literature. Furthermore, the experimental results indicate that TP-H can effectively and efficiently solve large-size problems in a reasonable time.
The effects of shape crowding on grasping.
Chen, Juan; Jayawardena, Sanasi; Goodale, Melvyn Alan
2015-03-10
Crowding refers to the deleterious effect of nearby objects on the identification of a target in the peripheral visual field. A recent study (Chen, Sperandio, & Goodale, 2015) showed that when a three-dimensional (3D) disk was crowded by disks of different sizes, participants could scale their grip aperture to the size of the target, even when they could not perceive its size. It is still unclear, however, whether or not grasping can also escape to some degree the crowding of other object features, such as shape. To test this, we presented 3D rectangular blocks in isolation or crowded by other blocks in the periphery. The target and flanking blocks had the same surface area but different dimensions. Participants were required either to grasp the target block across its width or to estimate its width. We found that, consistent with what we observed earlier with size, participants can also scale their grasp to the width of the target block even when they could not perceive its width. To further explore whether or not the effect of crowding on grasping depends on how proficient people are with their right hand, we had right-handed participants perform the same test but with their left hand. We found that left-hand grasping did not escape the crowding effect on shape perception at all. Taken together, our results suggest that people can also use invisible shape information to guide actions and that this ability depends on the proficiency of the action. © 2015 ARVO.
Quantification of soil structure based on Minkowski functions
NASA Astrophysics Data System (ADS)
Vogel, H.-J.; Weller, U.; Schlüter, S.
2010-10-01
The structure of soils and other geologic media is a complex three-dimensional object. Most of the physical material properties including mechanical and hydraulic characteristics are immediately linked to the structure given by the pore space and its spatial distribution. It is an old dream and still a formidable challenge to relate structural features of porous media to their functional properties. Using tomographic techniques, soil structure can be directly observed at a range of spatial scales. In this paper we present a scale-invariant concept to quantify complex structures based on a limited set of meaningful morphological functions. They are based on d+1 Minkowski functionals as defined for d-dimensional bodies. These basic quantities are determined as a function of pore size or aggregate size obtained by filter procedures using mathematical morphology. The resulting Minkowski functions provide valuable information on the size of pores and aggregates, the pore surface area and the pore topology having the potential to be linked to physical properties. The theoretical background and the related algorithms are presented and the approach is demonstrated for the pore structure of an arable soil and the pore structure of a sand both obtained by X-ray micro-tomography. We also analyze the fundamental problem of limited resolution which is critical for any attempt to quantify structural features at any scale using samples of different size recorded at different resolutions. The results demonstrate that objects smaller than 5 voxels are critical for quantitative analysis.
The coordination patterns observed when two hands reach-to-grasp separate objects.
Bingham, Geoffrey P; Hughes, Kirstie; Mon-Williams, Mark
2008-01-01
What determines coordination patterns when both hands reach to grasp separate objects at the same time? It is known that synchronous timing is preferred as the most stable mode of bimanual coordination. Nonetheless, normal unimanual prehension behaviour predicts asynchrony when the two hands reach towards unequal targets, with synchrony restricted to targets equal in size and distance. Additionally, sufficiently separated targets require sequential looking. Does synchrony occur in all cases because it is preferred in bimanual coordination or does asynchrony occur because of unimanual task constraints and the need for sequential looking? We investigated coordinative timing when participants (n = 8) moved their right (preferred) hand to the same object at a fixed distance but the left hand to objects of different width (3, 5, and 7 cm) and grip surface size (1, 2, and 3 cm) placed at different distances (20, 30, and 40 cm) over 270 randomised trials. The hand movements consisted of two components: (1) an initial component (IC) during which the hand reached towards the target while forming an appropriate grip aperture, stopping at (but not touching) the object; (2) a completion component (CC) during which the finger and thumb closed on the target. The two limbs started the IC together but did not interact until the deceleration phase when evidence of synchronisation began to appear. Nonetheless, asynchronous timing was present at the end of the IC and preserved through the CC even with equidistant targets. Thus, there was synchrony but requirements for visual information ultimately yielded asynchronous coordinative timing.
Jay R. Law; Craig G. Lorimer
1989-01-01
Maintaining uneven-aged stands involves cutting trees from a range of diameter classes in such a way that the residual stand has a balanced, steeply descending diameter distribution curve (fig. 1). The objective is to distribute trees by diameter classes so that over time the stand contains trees of different ages and sizes.
Ethnic Differences in Parental Attitudes and Beliefs about Being Overweight in Childhood
ERIC Educational Resources Information Center
Trigwell, J.; Watson, P. M.; Murphy, R. C.; Stratton, G.; Cable, N. T.
2014-01-01
Objective: This study examined the relationship between ethnic background and parental views of healthy body size, concerns surrounding overweight and attitudes to perceived causes of overweight in childhood. Method: A self-report questionnaire was designed to explore parental attitudes towards childhood weight. Sampling deliberately…
Problems in depth perception : perceived size and distance of familiar objects.
DOT National Transportation Integrated Search
1966-06-01
Judgments of the distance of familiar objects, especially other aircraft, are critical aspects of flight safety. In this study, the perception of distance as a function of the retinal size of a familiar object was investigated by simulating a station...
NASA Astrophysics Data System (ADS)
Lemal, Philipp; Geers, Christoph; Monnier, Christophe A.; Crippa, Federica; Daum, Leopold; Urban, Dominic A.; Rothen-Rutishauser, Barbara; Bonmarin, Mathias; Petri-Fink, Alke; Moore, Thomas L.
2017-04-01
Lock-in thermography (LIT) is a sensitive imaging technique generally used in engineering and materials science (e.g. detecting defects in composite materials). However, it has recently been expanded for investigating the heating power of nanomaterials, such as superparamagnetic iron oxide nanoparticles (SPIONs). Here we implement LIT as a rapid and reproducible method that can evaluate the heating potential of various sizes of SPIONs under an alternating magnetic field (AMF), as well as the limits of detection for each particle size. SPIONs were synthesized via thermal decomposition and stabilized in water via a ligand transfer process. Thermographic measurements of SPIONs were made by stimulating particles of varying sizes and increasing concentrations under an AMF. Furthermore, a commercially available SPION sample was included as an external reference. While the size dependent heating efficiency of SPIONs has been previously described, our objective was to probe the sensitivity limits of LIT. For certain size regimes it was possible to detect signals at concentrations as low as 0.1 mg Fe/mL. Measuring at different concentrations enabled a linear regression analysis and extrapolation of the limit of detection for different size nanoparticles.
Mannheim, Julia G; Schmid, Andreas M; Pichler, Bernd J
2017-12-01
Non-invasive in vivo positron emission tomography (PET) provides high detection sensitivity in the nano- to picomolar range and in addition to other advantages, the possibility to absolutely quantify the acquired data. The present study focuses on the comparison of transmission data acquired with an X-ray computed tomography (CT) scanner or a Co-57 source for the Inveon small animal PET scanner (Siemens Healthcare, Knoxville, TN, USA), as well as determines their influences on the quantification accuracy and partial volume effect (PVE). A special focus included the impact of the performed calibration on the quantification accuracy. Phantom measurements were carried out to determine the quantification accuracy, the influence of the object size on the quantification, and the PVE for different sphere sizes, along the field of view and for different contrast ratios. An influence of the emission activity on the Co-57 transmission measurements was discovered (deviations up to 24.06 % measured to true activity), whereas no influence of the emission activity on the CT attenuation correction was identified (deviations <3 % for measured to true activity). The quantification accuracy was substantially influenced by the applied calibration factor and by the object size. The PVE demonstrated a dependency on the sphere size, the position within the field of view, the reconstruction and correction algorithms and the count statistics. Depending on the reconstruction algorithm, only ∼30-40 % of the true activity within a small sphere could be resolved. The iterative 3D reconstruction algorithms uncovered substantially increased recovery values compared to the analytical and 2D iterative reconstruction algorithms (up to 70.46 % and 80.82 % recovery for the smallest and largest sphere using iterative 3D reconstruction algorithms). The transmission measurement (CT or Co-57 source) to correct for attenuation did not severely influence the PVE. The analysis of the quantification accuracy and the PVE revealed an influence of the object size, the reconstruction algorithm and the applied corrections. Particularly, the influence of the emission activity during the transmission measurement performed with a Co-57 source must be considered. To receive comparable results, also among different scanner configurations, standardization of the acquisition (imaging parameters, as well as applied reconstruction and correction protocols) is necessary.
Ensemble representations: effects of set size and item heterogeneity on average size perception.
Marchant, Alexander P; Simons, Daniel J; de Fockert, Jan W
2013-02-01
Observers can accurately perceive and evaluate the statistical properties of a set of objects, forming what is now known as an ensemble representation. The accuracy and speed with which people can judge the mean size of a set of objects have led to the proposal that ensemble representations of average size can be computed in parallel when attention is distributed across the display. Consistent with this idea, judgments of mean size show little or no decrement in accuracy when the number of objects in the set increases. However, the lack of a set size effect might result from the regularity of the item sizes used in previous studies. Here, we replicate these previous findings, but show that judgments of mean set size become less accurate when set size increases and the heterogeneity of the item sizes increases. This pattern can be explained by assuming that average size judgments are computed using a limited capacity sampling strategy, and it does not necessitate an ensemble representation computed in parallel across all items in a display. Copyright © 2012 Elsevier B.V. All rights reserved.
UXO Detection and Characterization using new Berkeley UXO Discriminator (BUD)
NASA Astrophysics Data System (ADS)
Gasperikova, E.; Morrison, H. F.; Smith, J. T.; Becker, A.
2006-05-01
An optimally designed active electromagnetic system (AEM), Berkeley UXO Discriminator, BUD, has been developed for detection and characterization of UXO in the 20 mm to 150 mm size range. The system incorporates three orthogonal transmitters, and eight pairs of differenced receivers. The transmitter-receiver assembly together with the acquisition box, as well as the battery power and GPS receiver, is mounted on a small cart to assure system mobility. BUD not only detects the object itself but also quantitatively determines its size, shape, orientation, and metal content (ferrous or non-ferrous, mixed metals). Moreover, the principal polarizabilities and size of a metallic target can be determined from a single position of the BUD platform. The search for UXO is a two-step process. The object must first be detected and its location determined then the parameters of the object must be defined. A satisfactory classification scheme is one that determines the principal dipole polarizabilities of a target. While UXO objects have a single major polarizability (principal moment) coincident with the long axis of the object and two equal transverse polarizabilities, the scrap metal has all three principal moments entirely different. This description of the inherent polarizabilities of a target is a major advance in discriminating UXO from irregular scrap metal. Our results clearly show that BUD can resolve the intrinsic polarizabilities of a target and that there are very clear distinctions between symmetric intact UXO and irregular scrap metal. Target properties are determined by an inversion algorithm, which at any given time inverts the response to yield the location (x, y, z) of the target, its attitude and its principal polarizabilities (yielding an apparent aspect ratio). Signal-to-noise estimates (or measurements) are interpreted in this inversion to yield error estimates on the location, attitude and polarizabilities. This inversion at a succession of times provides the polarizabilities as a function of time, which can in turn yield the size, true aspect ratio and estimates of the conductivity and permeability of the target. The accuracy of these property estimates depends on the time window over which the polarizability measurements, and their accuracies, are known. Initial tests at a local site over a variety of test objects and inert UXOs showed excellent detection and characterization results within the predicted size-depth range. This research was funded by the U.S. Department of Defense under ESTCP Project # UX-0437.
The Density of Mid-sized Kuiper Belt Objects from ALMA Thermal Observations
DOE Office of Scientific and Technical Information (OSTI.GOV)
Brown, Michael E.; Butler, Bryan J.
The densities of mid-sized Kuiper Belt objects (KBOs) are a key constraint in understanding the assembly of objects in the outer solar system. These objects are critical for understanding the currently unexplained transition from the smallest KBOs with densities lower than that of water, to the largest objects with significant rock content. Mapping this transition is made difficult by the uncertainties in the diameters of these objects, which maps into an even larger uncertainty in volume and thus density. The substantial collecting area of the Atacama Large Millimeter Array allows significantly more precise measurements of thermal emission from outer solarmore » system objects and could potentially greatly improve the density measurements. Here we use new thermal observations of four objects with satellites to explore the improvements possible with millimeter data. We find that effects due to effective emissivity at millimeter wavelengths make it difficult to use the millimeter data directly to find diameters and thus volumes for these bodies. In addition, we find that when including the effects of model uncertainty, the true uncertainties on the sizes of outer solar system objects measured with radiometry are likely larger than those previously published. Substantial improvement in object sizes will likely require precise occultation measurements.« less
Robust reflective ghost imaging against different partially polarized thermal light
NASA Astrophysics Data System (ADS)
Li, Hong-Guo; Wang, Yan; Zhang, Rui-Xue; Zhang, De-Jian; Liu, Hong-Chao; Li, Zong-Guo; Xiong, Jun
2018-03-01
We theoretically study the influence of degree of polarization (DOP) of thermal light on the contrast-to-noise ratio (CNR) of the reflective ghost imaging (RGI), which is a novel and indirect imaging modality. An expression for the CNR of RGI with partially polarized thermal light is carefully derived, which suggests a weak dependence of CNR on the DOP, especially when the ratio of the object size to the speckle size of thermal light has a large value. Different from conventional imaging approaches, our work reveals that RGI is much more robust against the DOP of the light source, which thereby has advantages in practical applications, such as remote sensing.
Sexual dimorphism in the human face assessed by euclidean distance matrix analysis.
Ferrario, V F; Sforza, C; Pizzini, G; Vogel, G; Miani, A
1993-01-01
The form of any object can be viewed as a combination of size and shape. A recently proposed method (euclidean distance matrix analysis) can differentiate between size and shape differences. It has been applied to analyse the sexual dimorphism in facial form in a sample of 108 healthy young adults (57 men, 51 women). The face was wider and longer in men than in women. A global shape difference was demonstrated, the male face being more rectangular and the female face more square. Gender variations involved especially the lower third of the face and, in particular, the position of the pogonion relative to the other structures. PMID:8300436
Noncontact orientation of objects in three-dimensional space using magnetic levitation
Subramaniam, Anand Bala; Yang, Dian; Yu, Hai-Dong; Nemiroski, Alex; Tricard, Simon; Ellerbee, Audrey K.; Soh, Siowling; Whitesides, George M.
2014-01-01
This paper describes several noncontact methods of orienting objects in 3D space using Magnetic Levitation (MagLev). The methods use two permanent magnets arranged coaxially with like poles facing and a container containing a paramagnetic liquid in which the objects are suspended. Absent external forcing, objects levitating in the device adopt predictable static orientations; the orientation depends on the shape and distribution of mass within the objects. The orientation of objects of uniform density in the MagLev device shows a sharp geometry-dependent transition: an analytical theory rationalizes this transition and predicts the orientation of objects in the MagLev device. Manipulation of the orientation of the levitating objects in space is achieved in two ways: (i) by rotating and/or translating the MagLev device while the objects are suspended in the paramagnetic solution between the magnets; (ii) by moving a small external magnet close to the levitating objects while keeping the device stationary. Unlike mechanical agitation or robotic selection, orienting using MagLev is possible for objects having a range of different physical characteristics (e.g., different shapes, sizes, and mechanical properties from hard polymers to gels and fluids). MagLev thus has the potential to be useful for sorting and positioning components in 3D space, orienting objects for assembly, constructing noncontact devices, and assembling objects composed of soft materials such as hydrogels, elastomers, and jammed granular media. PMID:25157136
Noncontact orientation of objects in three-dimensional space using magnetic levitation.
Subramaniam, Anand Bala; Yang, Dian; Yu, Hai-Dong; Nemiroski, Alex; Tricard, Simon; Ellerbee, Audrey K; Soh, Siowling; Whitesides, George M
2014-09-09
This paper describes several noncontact methods of orienting objects in 3D space using Magnetic Levitation (MagLev). The methods use two permanent magnets arranged coaxially with like poles facing and a container containing a paramagnetic liquid in which the objects are suspended. Absent external forcing, objects levitating in the device adopt predictable static orientations; the orientation depends on the shape and distribution of mass within the objects. The orientation of objects of uniform density in the MagLev device shows a sharp geometry-dependent transition: an analytical theory rationalizes this transition and predicts the orientation of objects in the MagLev device. Manipulation of the orientation of the levitating objects in space is achieved in two ways: (i) by rotating and/or translating the MagLev device while the objects are suspended in the paramagnetic solution between the magnets; (ii) by moving a small external magnet close to the levitating objects while keeping the device stationary. Unlike mechanical agitation or robotic selection, orienting using MagLev is possible for objects having a range of different physical characteristics (e.g., different shapes, sizes, and mechanical properties from hard polymers to gels and fluids). MagLev thus has the potential to be useful for sorting and positioning components in 3D space, orienting objects for assembly, constructing noncontact devices, and assembling objects composed of soft materials such as hydrogels, elastomers, and jammed granular media.
Bright, Leah; Secko, Michael; Mehta, Ninfa; Paladino, Lorenzo; Sinert, Richard
2014-01-01
Background: Ultrasound is a readily available, non-invasive technique to visualize airway dimensions at the patient's bedside and possibly predict difficult airways before invasively looking; however, it has rarely been used for emergency investigation of the larynx. There is limited literature on the sonographic measurements of true vocal cords in adults and normal parameters must be established before abnormal parameters can be accurately identified. Objectives: The primary objective of the following study is to identify the normal sonographic values of human true vocal cords in an adult population. A secondary objective is to determine if there is a difference in true vocal cord measurements in people with different body mass indices (BMIs). The third objective was to determine if there was a statistical difference in the measurements for both genders. Materials and Methods: True vocal cord measurements were obtained in healthy volunteers by ultrasound fellowship trained emergency medicine physicians using a high frequency linear transducer orientated transversely across the anterior surface of the neck at the level of the thyroid cartilage. The width of the true vocal cord was measured perpendicularly to the length of the cord at its mid-portion. This method was duplicated from a previous study to create a standard of measurement acquisition. Results: A total of 38 subjects were enrolled. The study demonstrated no correlation between vocal cord measurements and patient's characteristics of height, weight, or BMI's. When accounting for vocal cord measurements by gender, males had larger BMI's and larger vocal cord measurements compared with females subjects with a statistically significant different in right vocal cord measurements for females compared with male subjects. Conclusion: No correlation was seen between vocal cord measurements and person's BMIs. In the study group of normal volunteers, there was a difference in size between the male and female vocal cord size. PMID:24812456
Matheson, Heath E; White, Nicole C; McMullen, Patricia A
2014-07-01
Theories of embodied object representation predict a tight association between sensorimotor processes and visual processing of manipulable objects. Previous research has shown that object handles can 'potentiate' a manual response (i.e., button press) to a congruent location. This potentiation effect is taken as evidence that objects automatically evoke sensorimotor simulations in response to the visual presentation of manipulable objects. In the present series of experiments, we investigated a critical prediction of the theory of embodied object representations that potentiation effects should be observed with manipulable artifacts but not non-manipulable animals. In four experiments we show that (a) potentiation effects are observed with animals and artifacts; (b) potentiation effects depend on the absolute size of the objects and (c) task context influences the presence/absence of potentiation effects. We conclude that potentiation effects do not provide evidence for embodied object representations, but are suggestive of a more general stimulus-response compatibility effect that may depend on the distribution of attention to different object features.
Individual-Area Relationship Best Explains Goose Species Density in Wetlands
Prins, Herbert H. T.; Cao, Lei; de Boer, Willem Fred
2015-01-01
Explaining and predicting animal distributions is one of the fundamental objectives in ecology and conservation biology. Animal habitat selection can be regulated by top-down and bottom-up processes, and is mediated by species interactions. Species varying in body size respond differently to top-down and bottom-up determinants, and hence understanding these allometric responses to those determinants is important for conservation. In this study, using two differently sized goose species wintering in the Yangtze floodplain, we tested the predictions derived from three different hypotheses (individual-area relationship, food resource and disturbance hypothesis) to explain the spatial and temporal variation in densities of two goose species. Using Generalized Linear Mixed Models with a Markov Chain Monte Carlo technique, we demonstrated that goose density was positive correlated with patch area size, suggesting that the individual area-relationship best predicts differences in goose densities. Moreover, the other predictions, related to food availability and disturbance, were not significant. Buffalo grazing probably facilitated greater white-fronted geese, as the number of buffalos was positively correlated to the density of this species. We concluded that patch area size is the most important factor determining the density of goose species in our study area. Patch area size is directly determined by water levels in the Yangtze floodplain, and hence modifying the hydrological regimes can enlarge the capacity of these wetlands for migratory birds. PMID:25996502
Grouping principles in direct competition.
Schmidt, Filipp; Schmidt, Thomas
2013-08-09
We (1) introduce a primed flanker task as an objective method to measure perceptual grouping, and (2) use it to directly compare the efficiency of different grouping cues in rapid visuomotor processing. In two experiments, centrally presented primes were succeeded by flanking targets with varying stimulus-onset asynchronies (SOAs). Primes and targets were grouped by the same or by different grouping cues (Exp. 1: brightness/shape, Exp. 2: brightness/size) and were consistent or inconsistent with respect to the required response. Subjective grouping strength was varied to identify its influence on overall response times, error rates, and priming effects, that served as a measure of visual feedforward processing. Our results show that stronger grouping in the targets enhanced overall response times while stronger grouping in the primes enhanced priming effects in motor responses. Also, we obtained differences between rapid visuomotor processing and the subjective impression with cues of brightness and shape but not with cues of brightness and size. Our findings establish the primed flanker task as an objective method to study the speeded visuomotor processing of grouping cues, making it a useful method for the comparative study of feedforward-transmitted base groupings (Roelfsema & Houtkamp, 2011). Copyright © 2013 Elsevier Ltd. All rights reserved.
Li, Huan; Sinha, Tridib K; Oh, Jeong Seok; Kim, Jin Kuk
2018-04-25
Inspired by the epidermis-dermis composition of human skin, here we have simply developed a lightweight, robust, flexible, and biocompatible single-electrode triboelectric nanogenerator (S-TENG)-based prototype of bilayer artificial skin, by attaching one induction electrode with unfoamed skin layer of microcellular thermoplastic polyurethane (TPU) foam, which shows high-performance object manipulation [by responding differently toward different objects, viz., aluminum foil, balloon, cotton glove, human finger, glass, rubber glove, artificial leather, polyimide, poly(tetrafluoroethylene) (PTFE), paper, and wood], due to electrification and electrostatic induction during contact with the objects having different chemical functionalities. Comparative foaming behavior of ecofriendly supercritical fluids, viz., CO 2 over N 2 under variable temperatures (e.g., 130 and 150 °C) and constant pressure (15 MPa), have been examined here to pursue the soft and flexible triboelectric TPU foam. The foam derived by CO 2 foaming at 150 °C has been prioritized for development of S-TENG. Foam derived by CO 2 foaming at 130 °C did not respond as well due to the smaller cell size, higher hardness, and thicker skin. Inflexible N 2 -derived foam was not considered for S-TENG fabrication. Object manipulation performance has been visualized by principal component analysis (PCA), which shows good discrimination among responses to different objects.
On sample size and different interpretations of snow stability datasets
NASA Astrophysics Data System (ADS)
Schirmer, M.; Mitterer, C.; Schweizer, J.
2009-04-01
Interpretations of snow stability variations need an assessment of the stability itself, independent of the scale investigated in the study. Studies on stability variations at a regional scale have often chosen stability tests such as the Rutschblock test or combinations of various tests in order to detect differences in aspect and elevation. The question arose: ‘how capable are such stability interpretations in drawing conclusions'. There are at least three possible errors sources: (i) the variance of the stability test itself; (ii) the stability variance at an underlying slope scale, and (iii) that the stability interpretation might not be directly related to the probability of skier triggering. Various stability interpretations have been proposed in the past that provide partly different results. We compared a subjective one based on expert knowledge with a more objective one based on a measure derived from comparing skier-triggered slopes vs. slopes that have been skied but not triggered. In this study, the uncertainties are discussed and their effects on regional scale stability variations will be quantified in a pragmatic way. An existing dataset with very large sample sizes was revisited. This dataset contained the variance of stability at a regional scale for several situations. The stability in this dataset was determined using the subjective interpretation scheme based on expert knowledge. The question to be answered was how many measurements were needed to obtain similar results (mainly stability differences in aspect or elevation) as with the complete dataset. The optimal sample size was obtained in several ways: (i) assuming a nominal data scale the sample size was determined with a given test, significance level and power, and by calculating the mean and standard deviation of the complete dataset. With this method it can also be determined if the complete dataset consists of an appropriate sample size. (ii) Smaller subsets were created with similar aspect distributions to the large dataset. We used 100 different subsets for each sample size. Statistical variations obtained in the complete dataset were also tested on the smaller subsets using the Mann-Whitney or the Kruskal-Wallis test. For each subset size, the number of subsets were counted in which the significance level was reached. For these tests no nominal data scale was assumed. (iii) For the same subsets described above, the distribution of the aspect median was determined. A count of how often this distribution was substantially different from the distribution obtained with the complete dataset was made. Since two valid stability interpretations were available (an objective and a subjective interpretation as described above), the effect of the arbitrary choice of the interpretation on spatial variability results was tested. In over one third of the cases the two interpretations came to different results. The effect of these differences were studied in a similar method as described in (iii): the distribution of the aspect median was determined for subsets of the complete dataset using both interpretations, compared against each other as well as to the results of the complete dataset. For the complete dataset the two interpretations showed mainly identical results. Therefore the subset size was determined from the point at which the results of the two interpretations converged. A universal result for the optimal subset size cannot be presented since results differed between different situations contained in the dataset. The optimal subset size is thus dependent on stability variation in a given situation, which is unknown initially. There are indications that for some situations even the complete dataset might be not large enough. At a subset size of approximately 25, the significant differences between aspect groups (as determined using the whole dataset) were only obtained in one out of five situations. In some situations, up to 20% of the subsets showed a substantially different distribution of the aspect median. Thus, in most cases, 25 measurements (which can be achieved by six two-person teams in one day) did not allow to draw reliable conclusions.
Motor experience influences object knowledge.
Chrysikou, Evangelia G; Casasanto, Daniel; Thompson-Schill, Sharon L
2017-03-01
An object's perceived readiness-for-action (e.g., its size, the degree of rotation from its canonical position, the user's viewpoint) can influence semantic knowledge retrieval. Yet, the organization of object knowledge may also be affected by body-specific sensorimotor experiences. Here, we investigated whether people's history of performing motor actions with their hands influences the knowledge they store and retrieve about graspable objects. We compared object representations between healthy right- and left-handers (Experiment 1), and between unilateral stroke patients, whose motor experience was changed by impairment of either their right or left hand (Experiment 2). Participants saw pictures of graspable everyday items with the handles oriented toward either the left or right hand, and they generated the type of grasp they would employ (i.e., clench or pinch) when using each object, responding orally. In both experiments, hand dominance and object orientation interacted to predict response times. In Experiment 1, judgments were fastest when objects were oriented toward the right hand in right-handers, but not in left-handers. In Experiment 2, judgments were fastest when objects were oriented toward the left hand in patients who had lost the use of their right hand, even though these patients were right-handed prior to brain injury. Results suggest that at least some aspects of object knowledge are determined by motor experience, and can be changed by new patterns of motor experience. People with different bodily characteristics, who interact with objects in systematically different ways, form correspondingly different neurocognitive representations of the same common objects. (PsycINFO Database Record (c) 2017 APA, all rights reserved).
Straub, Jens; Valerius, Klaus-Peter; Pees, Michael; Krautwald-Junghanns, Maria-Elisabeth
2002-01-01
Due to lack of reference values an objective assessment of myocardial dilatation and hypertrophy in cage and aviary birds so far is not possible. Therefore the thickness of the myocardium of the left and the right ventricle of the heart of 14 budgerigars (Melopsittacus undulatus) and 5 Alisterus parrots (Alisterus s. scapularis) of both sexes was examined according to a standard protocol to establish morphometric data and first reference values. In order to compare the results of birds of different sizes all data were set in relation to the size of the bird's body (length of the sternum). Results of different zones were compared by means of statistical methods within one species. Besides that a comparison between the two species was performed. Only minor significant differences could be noticed.
Soft X-ray microscope with nanometer spatial resolution and its applications
NASA Astrophysics Data System (ADS)
Wachulak, P. W.; Torrisi, A.; Bartnik, A.; Wegrzynski, L.; Fok, T.; Patron, Z.; Fiedorowicz, H.
2016-12-01
A compact size microscope based on nitrogen double stream gas puff target soft X-ray source, which emits radiation in water-window spectral range at the wavelength of λ = 2.88 nm is presented. The microscope employs ellipsoidal grazing incidence condenser mirror for sample illumination and silicon nitride Fresnel zone plate objective for object magnification and imaging. The microscope is capable of capturing water-window images of objects with 60 nm spatial resolution and exposure time as low as a few seconds. Details about the microscopy system as well as some examples of different applications from various fields of science, are presented and discussed.
Development of Automated Objective Meteorological Techniques.
1980-11-30
differences are due largely to the nature and spatial distribution of the atmospheric data chosen as input for the model . The data for initial values and...technique. This report fo,-uses on results of theoretical investigations and data analyses performed oy SASC during the period May, 1979 to June, 1980...the sampling period, at a given point in space, the various size particles composing the particle distribution ex- hibit different velocities from each
Set size, individuation, and attention to shape.
Cantrell, Lisa; Smith, Linda B
2013-02-01
Much research has demonstrated a shape bias in categorizing and naming solid objects. This research has shown that when an entity is conceptualized as an individual object, adults and children attend to the object's shape. Separate research in the domain of numerical cognition suggest that there are distinct processes for quantifying small and large sets of discrete items. This research shows that small set discrimination, comparison, and apprehension is often precise for 1-3 and sometimes 4 items; however, large numerosity representation is imprecise. Results from three experiments suggest a link between the processes for small and large number representation and the shape bias in a forced choice categorization task using naming and non-naming procedures. Experiment 1 showed that adults generalized a newly learned name for an object to new instances of the same shape only when those instances were presented in sets of less than 3 or 4. Experiment 2 showed that preschool children who were monolingual speakers of three different languages were also influenced by set size when categorizing objects in sets. Experiment 3 extended these results and showed the same effect in a non-naming task and when the novel noun was presented in a count-noun syntax frame. The results are discussed in terms of a relation between the precision of object representation and the precision of small and large number representation. Copyright © 2012 Elsevier B.V. All rights reserved.
The Silhouette Zoetrope: A New Blend of Motion, Mirroring, Depth, and Size Illusions
Veras, Christine; Pham, Quang-Cuong
2017-01-01
Here, we report a novel combination of visual illusions in one stimulus device, a contemporary innovation of the traditional zoetrope, called Silhouette Zoetrope. In this new device, an animation of moving silhouettes is created by sequential cutouts placed outside a rotating empty cylinder, with slits illuminating the cutouts successively from the back. This “inside-out” zoetrope incurs the following visual effects: the resulting animated figures are perceived (a) horizontally flipped, (b) inside the cylinder, and (c) appear to be of different size than the actual cutout object. Here, we explore the unique combination of illusions in this new device. We demonstrate how the geometry of the device leads to a retinal image consistent with a mirrored and distorted image and binocular disparities consistent with the perception of an object inside the cylinder. PMID:28473908
Covariance Based Pre-Filters and Screening Criteria for Conjunction Analysis
NASA Astrophysics Data System (ADS)
George, E., Chan, K.
2012-09-01
Several relationships are developed relating object size, initial covariance and range at closest approach to probability of collision. These relationships address the following questions: - Given the objects' initial covariance and combined hard body size, what is the maximum possible value of the probability of collision (Pc)? - Given the objects' initial covariance, what is the maximum combined hard body radius for which the probability of collision does not exceed the tolerance limit? - Given the objects' initial covariance and the combined hard body radius, what is the minimum miss distance for which the probability of collision does not exceed the tolerance limit? - Given the objects' initial covariance and the miss distance, what is the maximum combined hard body radius for which the probability of collision does not exceed the tolerance limit? The first relationship above allows the elimination of object pairs from conjunction analysis (CA) on the basis of the initial covariance and hard-body sizes of the objects. The application of this pre-filter to present day catalogs with estimated covariance results in the elimination of approximately 35% of object pairs as unable to ever conjunct with a probability of collision exceeding 1x10-6. Because Pc is directly proportional to object size and inversely proportional to covariance size, this pre-filter will have a significantly larger impact on future catalogs, which are expected to contain a much larger fraction of small debris tracked only by a limited subset of available sensors. This relationship also provides a mathematically rigorous basis for eliminating objects from analysis entirely based on element set age or quality - a practice commonly done by rough rules of thumb today. Further, these relations can be used to determine the required geometric screening radius for all objects. This analysis reveals the screening volumes for small objects are much larger than needed, while the screening volumes for pairs of large objects may be inadequate. These relationships may also form the basis of an important metric for catalog maintenance by defining the maximum allowable covariance size for effective conjunction analysis. The application of these techniques promises to greatly improve the efficiency and completeness of conjunction analysis.
Impacts of Cellulose Fiber Particle Size and Starch Type on Expansion During Extrusion Processing.
Kallu, Sravya; Kowalski, Ryan J; Ganjyal, Girish M
2017-07-01
Objective of this study was to understand the impacts of cellulose fiber with different particle size distributions, and starches with different molecular weights, on the expansion of direct expanded products. Fiber with 3 different particle size distributions (<125, 150 to 250, 300 to 425 μm) and 4 types of starches representing different amylose contents (0%, 23%, 50%, and 70%) were investigated. Feed moisture content (18 ± 0.5 % w.b) and extruder temperature (140 °C) were kept constant and only the extruder screw speed was varied (100, 175, and 250 rpm) to achieve different specific mechanical energy inputs. Fiber particle size and starch type significantly influenced the various product parameters. In general, the smaller fiber particle size resulted in extrudate with higher expansion ratio. Starch with an amylose: amylopectin ratio of 23:77 resulted in highest expansion compared to the other starches, when no fiber was added. Interestingly, starch with 50:50, amylose: amylopectin ratio in combination with smaller fiber particles resulted in product with significantly greater expansion than the control starch extrudates. Aggregation of fiber and shrinkage of surface was observed in the Scanning Electron Microscope images at 10% fiber level. The results suggest the presence of active interactions between the cellulose fiber particles and corn starch molecules during the expansion process. A better understanding of these interactions can help in the development of high fiber extruded products with better expansion. © 2017 Institute of Food Technologists®.
Robinson, E; Nolan, S; Tudur-Smith, C; Boyland, E J; Harrold, J A; Hardman, C A; Halford, J C G
2014-10-01
It has been suggested that providing consumers with smaller dishware may prove an effective way of helping people eat less and preventing weight gain, but experimental evidence supporting this has been mixed. The objective of the present work was to examine the current evidence base for whether experimentally manipulated differences in dishware size influence food consumption. We systematically reviewed studies that experimentally manipulated the dishware size participants served themselves at a meal with and measured subsequent food intake. We used inverse variance meta-analysis, calculating the standardized mean difference (SMD) in food intake between smaller and larger dishware size conditions. Nine experiments from eight publications were eligible for inclusion. The majority of experiments found no significance difference in food intake when participants ate from smaller vs. larger dishware. With all available data included, analysis indicated a marginal effect of dishware size on food intake, with larger dishware size associated with greater intake. However, this effect was small and there was a large amount of heterogeneity across studies (SMD: -0.18, 95% confidence interval: -0.35, 0.00, I(2) = 77%). Evidence to date does not show that dishware size has a consistent effect on food intake, so recommendations surrounding the use of smaller plates/dishware to improve public health may be premature. © 2014 The Authors. obesity reviews © 2014 World Obesity.
Grasping trajectories in a virtual environment adhere to Weber's law.
Ozana, Aviad; Berman, Sigal; Ganel, Tzvi
2018-06-01
Virtual-reality and telerobotic devices simulate local motor control of virtual objects within computerized environments. Here, we explored grasping kinematics within a virtual environment and tested whether, as in normal 3D grasping, trajectories in the virtual environment are performed analytically, violating Weber's law with respect to object's size. Participants were asked to grasp a series of 2D objects using a haptic system, which projected their movements to a virtual space presented on a computer screen. The apparatus also provided object-specific haptic information upon "touching" the edges of the virtual targets. The results showed that grasping movements performed within the virtual environment did not produce the typical analytical trajectory pattern obtained during 3D grasping. Unlike as in 3D grasping, grasping trajectories in the virtual environment adhered to Weber's law, which indicates relative resolution in size processing. In addition, the trajectory patterns differed from typical trajectories obtained during 3D grasping, with longer times to complete the movement, and with maximum grip apertures appearing relatively early in the movement. The results suggest that grasping movements within a virtual environment could differ from those performed in real space, and are subjected to irrelevant effects of perceptual information. Such atypical pattern of visuomotor control may be mediated by the lack of complete transparency between the interface and the virtual environment in terms of the provided visual and haptic feedback. Possible implications of the findings to movement control within robotic and virtual environments are further discussed.
NASA Astrophysics Data System (ADS)
Pawcenis, Dominika; Smoleń, Mariusz; Aksamit-Koperska, Monika A.; Łojewski, Tomasz; Łojewska, Joanna
2016-06-01
Size exclusion chromatography (SEC), especially coupled with multiple angle laser light scattering detector (MALLS) is a powerful tool in diagnostics of deterioration of historic and art objects to evaluate their condition. In this paper, SEC-UV-MALLS-DRI technique was applied to study degradation of silk fibroin samples ( Bombyx mori) artificially aged under various conditions: in the presence of oxygen, in different amount of water vapour and in volatile organic products (VOCs), all at temperature of 90 °C. Conditions were chosen in such a way that it mimicked real conditions of textiles' storing during exhibitions and in show cases. The influence of temperature, moisture and VOCs content on the state of silk textiles was examined with the use of size exclusion chromatography. Pseudo-zero-order Ekenstam equation was applied to study degradation rates of fibroin with use of the approximated values of DP of fibroin.
Word Generalization by a Dog (Canis familiaris): Is Shape Important?
van der Zee, Emile; Zulch, Helen; Mills, Daniel
2012-01-01
We investigated the presence of a key feature of human word comprehension in a five year old Border Collie: the generalization of a word referring to an object to other objects of the same shape, also known as shape bias. Our first experiment confirmed a solid history of word learning in the dog, thus making it possible for certain object features to have become central in his word comprehension. Using an experimental paradigm originally employed to establish shape bias in children and human adults we taught the dog arbitrary object names (e.g. dax) for novel objects. Two experiments showed that when briefly familiarized with word-object mappings the dog did not generalize object names to object shape but to object size. A fourth experiment showed that when familiarized with a word-object mapping for a longer period of time the dog tended to generalize the word to objects with the same texture. These results show that the dog tested did not display human-like word comprehension, but word generalization and word reference development of a qualitatively different nature compared to humans. We conclude that a shape bias for word generalization in humans is due to the distinct evolutionary history of the human sensory system for object identification and that more research is necessary to confirm qualitative differences in word generalization between humans and dogs. PMID:23185321
Word generalization by a dog (Canis familiaris): is shape important?
van der Zee, Emile; Zulch, Helen; Mills, Daniel
2012-01-01
We investigated the presence of a key feature of human word comprehension in a five year old Border Collie: the generalization of a word referring to an object to other objects of the same shape, also known as shape bias. Our first experiment confirmed a solid history of word learning in the dog, thus making it possible for certain object features to have become central in his word comprehension. Using an experimental paradigm originally employed to establish shape bias in children and human adults we taught the dog arbitrary object names (e.g. dax) for novel objects. Two experiments showed that when briefly familiarized with word-object mappings the dog did not generalize object names to object shape but to object size. A fourth experiment showed that when familiarized with a word-object mapping for a longer period of time the dog tended to generalize the word to objects with the same texture. These results show that the dog tested did not display human-like word comprehension, but word generalization and word reference development of a qualitatively different nature compared to humans. We conclude that a shape bias for word generalization in humans is due to the distinct evolutionary history of the human sensory system for object identification and that more research is necessary to confirm qualitative differences in word generalization between humans and dogs.
Electrophysiological evidence for size invariance in masked picture repetition priming
Eddy, Marianna D.; Holcomb, Phillip J.
2009-01-01
This experiment examined invariance in object representations through measuring event-related potentials (ERPs) to pictures in a masked repetition priming paradigm. Pairs of pictures were presented where the prime was either the same size or half the size of the target object and the target was either presented in a normal orientation or was a normal sized mirror reflection of the prime object. Previous masked repetition priming studies have found a cascade of priming effect sensitive to perceptual (N190/P190) and semantic (N400) properties of the stimulus. This experiment found that both early (N190/P190 effects) and later effects (N400) were invariant to size, whereas only the N190/P190 effect was invariant to mirror reflection. The combination of a small prime and a mirror reflected target led to no significant priming effects. Taken together, the results of this set of experiments suggests that object recognition, more specifically, activating an object representation, occurs in a hierarchical fashion where overlapping perceptual information between the prime and target is necessary, although not always sufficient, to activate a higher level semantic representation. PMID:19560248
Faillace, M P; Pisera-Fuster, A; Medrano, M P; Bejarano, A C; Bernabeu, R O
2017-03-01
Zebrafish have a sophisticated color- and shape-sensitive visual system, so we examined color cue-based novel object recognition in zebrafish. We evaluated preference in the absence or presence of drugs that affect attention and memory retention in rodents: nicotine and the histone deacetylase inhibitor (HDACi) phenylbutyrate (PhB). The objective of this study was to evaluate whether nicotine and PhB affect innate preferences of zebrafish for familiar and novel objects after short- and long-retention intervals. We developed modified object recognition (OR) tasks using neutral novel and familiar objects in different colors. We also tested objects which differed with respect to the exploratory behavior they elicited from naïve zebrafish. Zebrafish showed an innate preference for exploring red or green objects rather than yellow or blue objects. Zebrafish were better at discriminating color changes than changes in object shape or size. Nicotine significantly enhanced or changed short-term innate novel object preference whereas PhB had similar effects when preference was assessed 24 h after training. Analysis of other zebrafish behaviors corroborated these results. Zebrafish were innately reluctant or prone to explore colored novel objects, so drug effects on innate preference for objects can be evaluated changing the color of objects with a simple geometry. Zebrafish exhibited recognition memory for novel objects with similar innate significance. Interestingly, nicotine and PhB significantly modified innate object preference.
Combining local and global limitations of visual search.
Põder, Endel
2017-04-01
There are different opinions about the roles of local interactions and central processing capacity in visual search. This study attempts to clarify the problem using a new version of relevant set cueing. A central precue indicates two symmetrical segments (that may contain a target object) within a circular array of objects presented briefly around the fixation point. The number of objects in the relevant segments, and density of objects in the array were varied independently. Three types of search experiments were run: (a) search for a simple visual feature (color, size, and orientation); (b) conjunctions of simple features; and (c) spatial configuration of simple features (rotated Ts). For spatial configuration stimuli, the results were consistent with a fixed global processing capacity and standard crowding zones. For simple features and their conjunctions, the results were different, dependent on the features involved. While color search exhibits virtually no capacity limits or crowding, search for an orientation target was limited by both. Results for conjunctions of features can be partly explained by the results from the respective features. This study shows that visual search is limited by both local interference and global capacity, and the limitations are different for different visual features.
Relative size perception at a distance is best at eye level
NASA Technical Reports Server (NTRS)
Bertamini, M.; Yang, T. L.; Proffitt, D. R.; Kaiser, M. K. (Principal Investigator)
1998-01-01
Relative size judgments were collected for two objects at 30.5 m and 23.8 from the observer in order to assess how performance depends on the relationship between the size of the objects and the eye level of the observer. In three experiments in an indoor hallway and in one experiment outdoors, accuracy was higher for objects in the neighborhood of eye level. We consider these results in the light of two hypotheses. One proposes that observers localize the horizon as a reference for judging relative size, and the other proposes that observers perceive the general neighborhood of the horizon and then employ a height-in-visual-field heuristic. The finding that relative size judgments are best around the horizon implies that information that is independent of distance perception is used in perceiving size.
2017-01-01
Summary Objective Manipulating plate sizes could possibly introduce perceptual biases for judging food satiation and intake, which is thought to be related to the Delbeouf illusion – a visual illusion based on the perceived size of one object related to another. This study was to investigate whether an association exists between an individual's susceptibility to the plate‐size‐effect and their weight status (i.e. normal‐weight versus overweight). Methods The study assessed the effect of plate size amongst normal‐weight (N = 124) and overweight (N = 79) New Zealand Europeans. All participants were asked to rate estimated satiation (ES) and intake (EI) on Visual Analogue Scales for 20 food images, which comprised photographs of ten different dishes placed on large versus small plates. These responses were analysed by mixed‐model ANCOVA. Results The results showed that the plate size had significant effects on ES (F (1, 1986) = 19.14, p < 0.001) and EI (F (1,1986) = 5.25; p = 0.048), with the small plate associated with higher ES and lower EI than the large plate. Significant differences in ES and EI were also evident across the weight groups (ES: F (1,1986) = 4.26, p = 0.039; EI: F (1,1986) = 42.22, p < 0.001), with the normal‐weight group reported higher ES and lower EI than the overweight group. Furthermore, the weight group and the plate‐size‐effect were found to be involved in a significant interaction for EI. Post‐hoc tests showed that the plate size only had a significant effect for the normal‐weight group (p < 0.05), but not for the overweight group. Conclusions Overall, the study demonstrated that the normal‐weight and overweight group differed in their susceptibilities to the plate‐size‐effect (reflected by EI). This study revealed some potential moderators for the plate‐size‐effect, such as the type of dish, and its associated appeal and familiarity, and provided useful indications about the effectiveness of small plates for food reduction. PMID:29071104
Motor Experience Influences Object Knowledge
Chrysikou, Evangelia G.; Casasanto, Daniel; Thompson-Schill, Sharon L.
2016-01-01
An object’s perceived readiness-for-action (e.g., its size, the degree of rotation from its canonical position, or the user’s viewpoint) can influence semantic knowledge retrieval. Yet, the organization of object knowledge may also be affected by body-specific sensorimotor experiences. Here, we investigated whether people’s history of performing motor actions with their hands influences the knowledge they store and retrieve about graspable objects. We compared object representations between healthy right- and left-handers (Experiment 1), and between unilateral stroke patients, whose motor experience was changed by impairment of either their right or left hand (Experiment 2). Participants saw pictures of graspable everyday items with the handles oriented toward either the left or right hand, and they generated the type of grasp they would employ (i.e., clench or pinch) when using each object, responding orally. In both experiments, hand dominance and object orientation interacted to predict response times. In Experiment 1, judgments were fastest when objects were oriented toward the right hand in right-handers, but not in left-handers. In Experiment 2, judgments were fastest when objects were oriented toward the left hand in patients who had lost the use of their right hand, even though these patients were right-handed prior to brain injury. Results suggest that at least some aspects of object knowledge are determined by motor experience, and can be changed by new patterns of motor experience. People with different bodily characteristics, who interact with objects in systematically different ways, form correspondingly different neurocognitive representations of the same common objects. PMID:28253009
NASA Astrophysics Data System (ADS)
Nadal Gisbert, Antonio V.
In this work is investigated the recycling of tires to elastomeric requirements by thermal compression. The production of recycled products is carried out starting from the powder, of elastomeric nature, coming from the grinding of used tires denominated GTR (Ground Tire Rubber) of different grain size, although the fundamental objective is the recycling of powder of 0,2mm grain size. The process of forming used for obtaining the recycled product is thermal compression, due to its simplicity and low cost. The composition of the powder has been analyzed and also the influence, on the elastomeric characteristics of the recycled product, of different parameters: Grain size, compact pressure, temperature, time, thickness of the recycled product and combination of sizes. At last we give an hypothesis that justifies the mechanism that gives cohesion to the powder GTR and allows their recycling. We also have carried out an analysis of the investigation lines, at the present, on the recycling of tires in general and an economic study of the viability of the recycled product in front of present products in the market, agglomerated with polyurethane, that have their application in using it in different types of floors.
Tooth-size discrepancy: A comparison between manual and digital methods
Correia, Gabriele Dória Cabral; Habib, Fernando Antonio Lima; Vogel, Carlos Jorge
2014-01-01
Introduction Technological advances in Dentistry have emerged primarily in the area of diagnostic tools. One example is the 3D scanner, which can transform plaster models into three-dimensional digital models. Objective This study aimed to assess the reliability of tooth size-arch length discrepancy analysis measurements performed on three-dimensional digital models, and compare these measurements with those obtained from plaster models. Material and Methods To this end, plaster models of lower dental arches and their corresponding three-dimensional digital models acquired with a 3Shape R700T scanner were used. All of them had lower permanent dentition. Four different tooth size-arch length discrepancy calculations were performed on each model, two of which by manual methods using calipers and brass wire, and two by digital methods using linear measurements and parabolas. Results Data were statistically assessed using Friedman test and no statistically significant differences were found between the two methods (P > 0.05), except for values found by the linear digital method which revealed a slight, non-significant statistical difference. Conclusions Based on the results, it is reasonable to assert that any of these resources used by orthodontists to clinically assess tooth size-arch length discrepancy can be considered reliable. PMID:25279529
Two-Year-Old Children Interpret Abstract, Purely Geometric Maps
ERIC Educational Resources Information Center
Winkler-Rhoades, Nathan; Carey, Susan C.; Spelke, Elizabeth S.
2013-01-01
In two experiments, 2.5-year-old children spontaneously used geometric information from 2D maps to locate objects in a 3D surface layout, without instruction or feedback. Children related maps to their corresponding layouts even though the maps differed from the layouts in size, mobility, orientation, dimensionality, and perspective, and even when…
USDA-ARS?s Scientific Manuscript database
The objective of this study is to investigate single nucleotide polymorphism (SNP) genotypes imputation of Hereford cattle. Purebred Herefords were from two sources, Line 1 Hereford (N=240) and representatives of Industry Herefords (N=311). Using different reference panels of 62 and 494 males with 1...
EDUCATIONAL AND VOCATIONAL GOALS OF RURAL YOUTH IN THE SOUTH.
ERIC Educational Resources Information Center
SPERRY, IRWIN V.; AND OTHERS
THE OBJECTIVES OF THE STUDY WERE TO--(1) COMPARE EDUCATIONAL GOALS OF RURAL YOUTH AND THEIR PARENTS AND (2) DETERMINE THE RELATIONSHIPS OF THE SIMILARITIES AND DIFFERENCES TO SUCH FACTORS AS GEOGRAPHIC AREA, STATE, SEX, LEVEL OF LIVING, RESIDENCE, FAMILY SIZE, AND CLUB MEMBERSHIP. A SURVEY SAMPLE, SELECTED FROM AN EQUIPARTITIONED UNIVERSE…
Deferment cutting in Appalachian hardwoods: the what, whys, and hows
H. Clay Smith; Gary W. Miller
1991-01-01
Deferment cutting is a regeneration practice that resembles a seed-tree or shelterwood cutting. The difference is that residual trees are not cut when the reproduction becomes established. Instead, residual trees are left until new reproduction matures to sawtimber size, and another regeneration cut is the silvicultural objective. Hence, with deferment cutting specific...
Lymph node detection in IASLC-defined zones on PET/CT images
NASA Astrophysics Data System (ADS)
Song, Yihua; Udupa, Jayaram K.; Odhner, Dewey; Tong, Yubing; Torigian, Drew A.
2016-03-01
Lymph node detection is challenging due to the low contrast between lymph nodes as well as surrounding soft tissues and the variation in nodal size and shape. In this paper, we propose several novel ideas which are combined into a system to operate on positron emission tomography/ computed tomography (PET/CT) images to detect abnormal thoracic nodes. First, our previous Automatic Anatomy Recognition (AAR) approach is modified where lymph node zones predominantly following International Association for the Study of Lung Cancer (IASLC) specifications are modeled as objects arranged in a hierarchy along with key anatomic anchor objects. This fuzzy anatomy model built from diagnostic CT images is then deployed on PET/CT images for automatically recognizing the zones. A novel globular filter (g-filter) to detect blob-like objects over a specified range of sizes is designed to detect the most likely locations and sizes of diseased nodes. Abnormal nodes within each automatically localized zone are subsequently detected via combined use of different items of information at various scales: lymph node zone model poses found at recognition indicating the geographic layout at the global level of node clusters, g-filter response which hones in on and carefully selects node-like globular objects at the node level, and CT and PET gray value but within only the most plausible nodal regions for node presence at the voxel level. The models are built from 25 diagnostic CT scans and refined for an object hierarchy based on a separate set of 20 diagnostic CT scans. Node detection is tested on an additional set of 20 PET/CT scans. Our preliminary results indicate node detection sensitivity and specificity at around 90% and 85%, respectively.
Russ, M; Shankar, A; Jain, A; Setlur Nagesh, S V; Ionita, C N; Scott, C; Karim, K S; Bednarek, D R; Rudin, S
2016-02-27
A novel amorphous selenium (a-Se) direct detector with CMOS readout has been designed, and relative detector performance investigated. The detector features include a 25 μ m pixel pitch, and 1000 μ m thick a-Se layer operating at 10V/ μ m bias field. A simulated detector DQE was determined, and used in comparative calculations of the Relative Object Detectability (ROD) family of prewhitening matched-filter (PWMF) observer and non-prewhitening matched filter (NPWMF) observer model metrics to gauge a-Se detector performance against existing high resolution micro-angiographic fluoroscopic (MAF) detectors and a standard flat panel detector (FPD). The PWMF-ROD or ROD metric compares two x-ray imaging detectors in their relative abilities in imaging a given object by taking the integral over spatial frequencies of the Fourier transform of the detector DQE weighted by an object function, divided by the comparable integral for a different detector. The generalized-ROD (G-ROD) metric incorporates clinically relevant parameters (focal-spot size, magnification, and scatter) to show the degradation in imaging performance for detectors that are part of an imaging chain. Preliminary ROD calculations using simulated spheres as the object predicted superior imaging performance by the a-Se detector as compared to existing detectors. New PWMF-G-ROD and NPWMF-G-ROD results still indicate better performance by the a-Se detector in an imaging chain over all sphere sizes for various focal spot sizes and magnifications, although a-Se performance advantages were degraded by focal spot blurring. Nevertheless, the a-Se technology has great potential to provide breakthrough abilities such as visualization of fine details including of neuro-vascular perforator vessels and of small vascular devices.
NASA Astrophysics Data System (ADS)
Russ, M.; Shankar, A.; Jain, A.; Setlur Nagesh, S. V.; Ionita, C. N.; Scott, C.; Karim, K. S.; Bednarek, D. R.; Rudin, S.
2016-03-01
A novel amorphous selenium (a-Se) direct detector with CMOS readout has been designed, and relative detector performance investigated. The detector features include a 25μm pixel pitch, and 1000μm thick a-Se layer operating at 10V/μm bias field. A simulated detector DQE was determined, and used in comparative calculations of the Relative Object Detectability (ROD) family of prewhitening matched-filter (PWMF) observer and non-pre-whitening matched filter (NPWMF) observer model metrics to gauge a-Se detector performance against existing high resolution micro-angiographic fluoroscopic (MAF) detectors and a standard flat panel detector (FPD). The PWMF-ROD or ROD metric compares two x-ray imaging detectors in their relative abilities in imaging a given object by taking the integral over spatial frequencies of the Fourier transform of the detector DQE weighted by an object function, divided by the comparable integral for a different detector. The generalized-ROD (G-ROD) metric incorporates clinically relevant parameters (focal- spot size, magnification, and scatter) to show the degradation in imaging performance for detectors that are part of an imaging chain. Preliminary ROD calculations using simulated spheres as the object predicted superior imaging performance by the a-Se detector as compared to existing detectors. New PWMF-G-ROD and NPWMF-G-ROD results still indicate better performance by the a-Se detector in an imaging chain over all sphere sizes for various focal spot sizes and magnifications, although a-Se performance advantages were degraded by focal spot blurring. Nevertheless, the a-Se technology has great potential to provide break- through abilities such as visualization of fine details including of neuro-vascular perforator vessels and of small vascular devices.
Russ, M.; Shankar, A.; Jain, A.; Setlur Nagesh, S. V.; Ionita, C. N.; Scott, C.; Karim, K. S.; Bednarek, D. R.; Rudin, S.
2017-01-01
A novel amorphous selenium (a-Se) direct detector with CMOS readout has been designed, and relative detector performance investigated. The detector features include a 25μm pixel pitch, and 1000μm thick a-Se layer operating at 10V/μm bias field. A simulated detector DQE was determined, and used in comparative calculations of the Relative Object Detectability (ROD) family of prewhitening matched-filter (PWMF) observer and non-prewhitening matched filter (NPWMF) observer model metrics to gauge a-Se detector performance against existing high resolution micro-angiographic fluoroscopic (MAF) detectors and a standard flat panel detector (FPD). The PWMF-ROD or ROD metric compares two x-ray imaging detectors in their relative abilities in imaging a given object by taking the integral over spatial frequencies of the Fourier transform of the detector DQE weighted by an object function, divided by the comparable integral for a different detector. The generalized-ROD (G-ROD) metric incorporates clinically relevant parameters (focal-spot size, magnification, and scatter) to show the degradation in imaging performance for detectors that are part of an imaging chain. Preliminary ROD calculations using simulated spheres as the object predicted superior imaging performance by the a-Se detector as compared to existing detectors. New PWMF-G-ROD and NPWMF-G-ROD results still indicate better performance by the a-Se detector in an imaging chain over all sphere sizes for various focal spot sizes and magnifications, although a-Se performance advantages were degraded by focal spot blurring. Nevertheless, the a-Se technology has great potential to provide breakthrough abilities such as visualization of fine details including of neuro-vascular perforator vessels and of small vascular devices. PMID:28615795
The Electric Field of a Weakly Electric Fish
NASA Astrophysics Data System (ADS)
Rasnow, Brian K.
Freshwater fish of the genus Apteronotus (family Gymnotidae) generate a weak, high frequency electric field (<100 mV/cm, 0.5-10 kHz) which permeates their local environment. These nocturnal fish are acutely sensitive to perturbations in their electric field caused by other electric fish, and nearby objects whose impedance is different from the surrounding water. This thesis presents high temporal and spatial resolution maps of the electric potential and field on and near Apteronotus. The fish's electric field is a complicated and highly stable function of space and time. Its characteristics, such as spectral composition, timing, and rate of attenuation, are examined in terms of physical constraints, and their possible functional roles in electroreception. Temporal jitter of the periodic field is less than 1 musec. However, electrocyte activity is not globally synchronous along the fish's electric organ. The propagation of electrocyte activation down the fish's body produces a rotation of the electric field vector in the caudal part of the fish. This may assist the fish in identifying nonsymmetrical objects, and could also confuse electrosensory predators that try to locate Apteronotus by following its fieldlines. The propagation also results in a complex spatiotemporal pattern of the EOD potential near the fish. Visualizing the potential on the same and different fish over timescales of several months suggests that it is stable and could serve as a unique signature for individual fish. Measurements of the electric field were used to calculate the effects of simple objects on the fish's electric field. The shape of the perturbation or "electric image" on the fish's skin is relatively independent of a simple object's size, conductivity, and rostrocaudal location, and therefore could unambiguously determine object distance. The range of electrolocation may depend on both the size of objects and their rostrocaudal location. Only objects with very large dielectric constants cause appreciable phase shifts, and these are strongly dependent on the water conductivity.
NASA Technical Reports Server (NTRS)
Barker, Ed; Abercromby, Kira J.; Abell, Paul
2009-01-01
A key objective of NASA s Orbital Debris program office at Johnson Space Center (JSC) is to characterize the debris environment by way of assessing the physical properties (type, mass, density, and size) of objects in orbit. Knowledge of the geosynchronous orbit (GEO) debris environment in particular can be used to determine the hazard probability at specific GEO altitudes and aid predictions of the future environment. To calculate an optical size from an intensity measurement of an object in the GEO regime, a 0.175 albedo is assumed currently. However, identification of specific material type or types could improve albedo accuracy and yield a more accurate size estimate for the debris piece. Using spectroscopy, it is possible to determine the surface materials of space objects. The study described herein used the NASA Infrared Telescope Facility (IRTF) to record spectral data in the 0.6 to 2.5 micron regime on eight catalogued space objects. For comparison, all of the objects observed were in GEO or near-GEO. The eight objects consisted of two intact spacecraft, three rocket bodies, and three catalogued debris pieces. Two of the debris pieces stemmed from Titan 3C transtage breakup and the third is from COSMOS 2054. The reflectance spectra of the Titan 3C pieces share similar slopes (increasing with wavelength) and lack any strong absorption features. The COSMOS debris spectra is flat and has no absorption features. In contrast, the intact spacecraft show classic absorption features due to solar panels with a strong band gap feature near 1 micron. The two spacecraft are spin-stabilized objects and therefore have solar panels surrounding the outer surface. Two of the three rocket bodies are inertial upper stage (IUS) rocket bodies and have similar looking spectra. The slopes flatten out near 1.5 microns with absorption features in the near-infrared that are similar to that of white paint. The third rocket body has a similar flattening of slope but with fewer features of white paint - indicating that the surface paint on the SL-12 may be different than the IUS. This study shows that the surface materials of debris appear different spectrally than intact rocket bodies and spacecraft and therefore are not believed to be solar panel material or pristine white paint. Further investigation is necessary in order to eliminate materials as possible choices for the debris pieces.
NASA Astrophysics Data System (ADS)
Albercromby, Kira J.; Abell, Paul; Barker, Ed
2009-03-01
A key objective of NASA's Orbital Debris program office at Johnson Space Center (JSC) is to characterize the debris environment by way of assessing the physical properties (type, mass, density, and size) of objects in orbit. Knowledge of the geosynchronous orbit (GEO) debris environment in particular can be used to determine the hazard probability at specific GEO altitudes and aid predictions of the future environment. To calculate an optical size from an intensity measurement of an object in the GEO regime, a 0.175 albedo is assumed currently. However, identification of specific material type or types could improve albedo accuracy and yield a more accurate size estimate for the debris piece. Using spectroscopy, it is possible to determine the surface materials of space objects. The study described herein used the NASA Infrared Telescope Facility (IRTF) to record spectral data in the ~ 0.65 to 2.5 micron regime on eight catalogued space objects. For comparison, all of the objects observed were in GEO or near-GEO. The eight objects consisted of two intact spacecraft, three rocket bodies, and three catalogued debris pieces. Two of the debris pieces stemmed from Titan 3C transtage breakup and the third is from COSMOS 2054. The reflectance spectra of the Titan 3C pieces share similar slopes (increasing with wavelength) and lack any strong absorption features. The COSMOS debris spectrum has a slight slope and has no absorption features. In contrast, the intact spacecraft show classic absorption features due to solar cells with a strong band gap feature near 1 micron. The two spacecraft were spin-stabilized objects and therefore have solar panels surrounding the outer surface. Two of the three rocket bodies are inertial upper stage (IUS) rocket bodies and have similar looking spectra. The slopes flatten out near 1.5 microns with absorption features in the near-infrared that are similar to that of white paint. The third rocket body has a similar flattening of slope but with fewer features of white paint - indicating that the surface paint on the SL-12 may be different than the IUS. This study shows that the surface materials of debris appear different spectrally than intact rocket bodies and spacecraft and therefore are not believed to be solar cell material or pristine white paint. Further investigation is necessary in order to eliminate materials as possible choices for the debris pieces.
Ultrasound detection of simulated intra-ocular foreign bodies by minimally trained personnel.
Sargsyan, Ashot E; Dulchavsky, Alexandria G; Adams, James; Melton, Shannon; Hamilton, Douglas R; Dulchavsky, Scott A
2008-01-01
To test the ability of non-expert ultrasound operators of divergent backgrounds to detect the presence, size, location, and composition of foreign bodies in an ocular model. High school students (N = 10) and NASA astronauts (N = 4) completed a brief ultrasound training session which focused on basic ultrasound principles and the detection of foreign bodies. The operators used portable ultrasound devices to detect foreign objects of varying location, size (0.5-2 mm), and material (glass, plastic, metal) in a gelatinous ocular model. Operator findings were compared to known foreign object parameters and ultrasound experts (N = 2) to determine accuracy across and between groups. Ultrasound had high sensitivity (astronauts 85%, students 87%, and experts 100%) and specificity (astronauts 81%, students 83%, and experts 95%) for the detection of foreign bodies. All user groups were able to accurately detect the presence of foreign bodies in this model (astronauts 84%, students 81%, and experts 97%). Astronaut and student sensitivity results for material (64% vs. 48%), size (60% vs. 46%), and position (77% vs. 64%) were not statistically different. Experts' results for material (85%), size (90%), and position (98%) were higher; however, the small sample size precluded statistical conclusions. Ultrasound can be used by operators with varying training to detect the presence, location, and composition of intraocular foreign bodies with high sensitivity, specificity, and accuracy.
NASA Technical Reports Server (NTRS)
Ellis, Stephen R.; Menges, Brian M.
1998-01-01
Errors in the localization of nearby virtual objects presented via see-through, helmet mounted displays are examined as a function of viewing conditions and scene content in four experiments using a total of 38 subjects. Monocular, biocular or stereoscopic presentation of the virtual objects, accommodation (required focus), subjects' age, and the position of physical surfaces are examined. Nearby physical surfaces are found to introduce localization errors that differ depending upon the other experimental factors. These errors apparently arise from the occlusion of the physical background by the optically superimposed virtual objects. But they are modified by subjects' accommodative competence and specific viewing conditions. The apparent physical size and transparency of the virtual objects and physical surfaces respectively are influenced by their relative position when superimposed. The design implications of the findings are discussed in a concluding section.
Reconstruction methods for phase-contrast tomography
DOE Office of Scientific and Technical Information (OSTI.GOV)
Raven, C.
Phase contrast imaging with coherent x-rays can be distinguished in outline imaging and holography, depending on the wavelength {lambda}, the object size d and the object-to-detector distance r. When r << d{sup 2}{lambda}, phase contrast occurs only in regions where the refractive index fastly changes, i.e. at interfaces and edges in the sample. With increasing object-to-detector distance we come in the area of holographic imaging. The image contrast outside the shadow region of the object is due to interference of the direct, undiffracted beam and a beam diffracted by the object, or, in terms of holography, the interference of amore » reference wave with the object wave. Both, outline imaging and holography, offer the possibility to obtain three dimensional information of the sample in conjunction with a tomographic technique. But the data treatment and the kind of information one can obtain from the reconstruction is different.« less
Inattentional blindness is influenced by exposure time not motion speed.
Kreitz, Carina; Furley, Philip; Memmert, Daniel
2016-01-01
Inattentional blindness is a striking phenomenon in which a salient object within the visual field goes unnoticed because it is unexpected, and attention is focused elsewhere. Several attributes of the unexpected object, such as size and animacy, have been shown to influence the probability of inattentional blindness. At present it is unclear whether or how the speed of a moving unexpected object influences inattentional blindness. We demonstrated that inattentional blindness rates are considerably lower if the unexpected object moves more slowly, suggesting that it is the mere exposure time of the object rather than a higher saliency potentially induced by higher speed that determines the likelihood of its detection. Alternative explanations could be ruled out: The effect is not based on a pop-out effect arising from different motion speeds in relation to the primary-task stimuli (Experiment 2), nor is it based on a higher saliency of slow-moving unexpected objects (Experiment 3).
Dangerous Near-Earth Asteroids and Meteorites
NASA Astrophysics Data System (ADS)
Mickaelian, A. M.; Grigoryan, A. E.
2015-07-01
The problem of Near-Earth Objects (NEOs; Astreoids and Meteorites) is discussed. To have an understanding on the probablity of encounters with such objects, one may use two different approaches: 1) historical, based on the statistics of existing large meteorite craters on the Earth, estimation of the source meteorites size and the age of these craters to derive the frequency of encounters with a given size of meteorites and 2) astronomical, based on the study and cataloging of all medium-size and large bodies in the Earth's neighbourhood and their orbits to estimate the probability, angles and other parameters of encounters. Therefore, we discuss both aspects and give our present knowledge on both phenomena. Though dangerous NEOs are one of the main source for cosmic catastrophes, we also focus on other possible dangers, such as even slight changes of Solar irradiance or Earth's orbit, change of Moon's impact on Earth, Solar flares or other manifestations of Solar activity, transit of comets (with impact on Earth's atmosphere), global climate change, dilution of Earth's atmosphere, damage of ozone layer, explosion of nearby Supernovae, and even an attack by extraterrestrial intelligence.
NASA Astrophysics Data System (ADS)
Sánchez-Ortiz, Noelia; Domínguez-González, Raúl; Krag, Holger
2015-03-01
One of the main objectives of Space Surveillance and Tracking (SST) systems is to support space collision avoidance activities. This collision avoidance capability aims to significantly reduce the catastrophic collision risk of space objects. In particular, for the case of the future European SST, the objective is translated into a risk reduction of one order of magnitude whilst keeping a low number of false alarm events. In order to translate this aim into system requirements, an evaluation of the current catastrophic collision risk for different orbital regimes is addressed. The reduction of such risk depends on the amount of catalogued objects (coverage) and the knowledge of the associated orbits in the catalogue (accuracy). This paper presents an analysis of the impact of those two aspects in the capability to reduce the catastrophic collision risk at some orbital regimes. A reliable collision avoidance support depends on the accuracy of the predicted miss-events. The assessment of possible conjunctions is normally done by computing the estimated miss-distances between objects (which is compared with a defined distance threshold) or by computing the associated collision risk (which is compared with the corresponding accepted collision probability level). This second method is normally recommended because it takes into account the reliability of the orbits and allows reducing false alarm events. The collision risk depends on the estimated miss-distance, the object sizes and the accuracy of the two orbits at the time of event. This accuracy depends on the error of the orbits at the orbit determination epoch and the error derived from the propagation from that epoch up to the time of event. The modified DRAMA ARES (Domínguez-González et al., 2012, 2013a,b; Gelhaus et al., 2014) provides information on the expected number of encounters for a given mission and year. It also provides information on the capacity to reduce the risk of collision by means of avoidance manoeuvres as a function of the accepted collision probability level and the cataloguing performance of the surveillance system (determined by the limiting coverage size-altitude function and the orbital data accuracy). The assessment of avoidance strategies takes into account statistical models of the space object environment, as provided by ESA's MASTER-2009 model, and a mathematical framework for the collision risk estimation as used in satellite operations. In this papers, results are provided for some orbit types, covering different orbital regimes. The analysis is done for different cataloguing capacity levels (accuracy and coverage), concluding that 5 cm are to be covered at LEO for diminishing the catastrophic collision risk by one order of magnitude. For MEO and GEO regime, coverage down to 40 and 100 cm respectively allow similar reduction of risk.
Lv, Nan; Yu, Ying; Xu, Jinyu; Karmonik, Christof; Liu, Jianmin; Huang, Qinghai
2016-08-01
OBJECT Unruptured posterior communicating artery (PCoA) aneurysms with oculomotor nerve palsy (ONP) have a very high risk of rupture. This study investigated the hemodynamic and morphological characteristics of intracranial aneurysms with high rupture risk by analyzing PCoA aneurysms with ONP. METHODS Fourteen unruptured PCoA aneurysms with ONP, 33 ruptured PCoA aneurysms, and 21 asymptomatic unruptured PCoA aneurysms were included in this study. The clinical, morphological, and hemodynamic characteristics were compared among the different groups. RESULTS The clinical characteristics did not differ among the 3 groups (p > 0.05), whereas the morphological and hemodynamic analyses showed that size, aspect ratio, size ratio, undulation index, nonsphericity index, ellipticity index, normalized wall shear stress (WSS), and percentage of low WSS area differed significantly (p < 0.05) among the 3 groups. Furthermore, multiple comparisons revealed that these parameters differed significantly between the ONP group and the asymptomatic unruptured group and between the ruptured group and the asymptomatic unruptured group, except for size, which differed significantly only between the ONP group and the asymptomatic unruptured group (p = 0.0005). No morphological or hemodynamic parameters differed between the ONP group and the ruptured group. CONCLUSIONS Unruptured PCoA aneurysms with ONP demonstrated a distinctive morphological-hemodynamic pattern that was significantly different compared with asymptomatic unruptured PCoA aneurysms and was similar to ruptured PCoA aneurysms. The larger size, more irregular shape, and lower WSS might be related to the high rupture risk of PCoA aneurysms.
Size matters: bigger is faster.
Sereno, Sara C; O'Donnell, Patrick J; Sereno, Margaret E
2009-06-01
A largely unexplored aspect of lexical access in visual word recognition is "semantic size"--namely, the real-world size of an object to which a word refers. A total of 42 participants performed a lexical decision task on concrete nouns denoting either big or small objects (e.g., bookcase or teaspoon). Items were matched pairwise on relevant lexical dimensions. Participants' reaction times were reliably faster to semantically "big" versus "small" words. The results are discussed in terms of possible mechanisms, including more active representations for "big" words, due to the ecological importance attributed to large objects in the environment and the relative speed of neural responses to large objects.
[Study of the reliability in one dimensional size measurement with digital slit lamp microscope].
Wang, Tao; Qi, Chaoxiu; Li, Qigen; Dong, Lijie; Yang, Jiezheng
2010-11-01
To study the reliability of digital slit lamp microscope as a tool for quantitative analysis in one dimensional size measurement. Three single-blinded observers acquired and repeatedly measured the images with a size of 4.00 mm and 10.00 mm on the vernier caliper, which simulatated the human eye pupil and cornea diameter under China-made digital slit lamp microscope in the objective magnification of 4 times, 10 times, 16 times, 25 times, 40 times and 4 times, 10 times, 16 times, respectively. The correctness and precision of measurement were compared. The images with 4 mm size were measured by three investigators and the average values were located between 3.98 to 4.06. For the images with 10.00 mm size, the average values fell within 10.00 ~ 10.04. Measurement results of 4.00 mm images showed, except A4, B25, C16 and C25, significant difference was noted between the measured value and the true value. Regarding measurement results of 10.00 mm iamges indicated, except A10, statistical significance was found between the measured value and the true value. In terms of comparing the results of the same size measured at different magnifications by the same investigator, except for investigators A's measurements of 10.00 mm dimension, the measurement results by all the remaining investigators presented statistical significance at different magnifications. Compared measurements of the same size with different magnifications, measurements of 4.00 mm in 4-fold magnification had no significant difference among the investigators', the remaining results were statistically significant. The coefficient of variation of all measurement results were less than 5%; as magnification increased, the coefficient of variation decreased. The measurement of digital slit lamp microscope in one-dimensional size has good reliability,and should be performed for reliability analysis before used for quantitative analysis to reduce systematic errors.
The object-based Simon effect: grasping affordance or relative location of the graspable part?
Cho, Dongbin Tobin; Proctor, Robert W
2010-08-01
Reaction time is often shorter when the irrelevant graspable handle of an object corresponds with the location of a keypress response to the relevant attribute than when it does not. This object-based Simon effect has been attributed to an affordance for grasping the handle with the hand to the same side. Because a grasping affordance should differentially affect keypress responses only when they are made with different hands, we conducted three experiments that measured the object-based Simon effect for frying pan stimuli using between- and within-hand response sets. When the relevant stimulus dimension was color, neither the object-based Simon effect nor the location-based Simon effect varied across response sets. When upright-inverted orientation judgments were made for the frying pan and for nongraspable stimuli derived from it, there again was no significant difference in size of the between- and within-hand Simon effects for any of the stimuli. The results provide evidence that the Simon effect for graspable frying pan stimuli is because of relative location of the handle and not to a grasping affordance.
Dynamic cellular manufacturing system considering machine failure and workload balance
NASA Astrophysics Data System (ADS)
Rabbani, Masoud; Farrokhi-Asl, Hamed; Ravanbakhsh, Mohammad
2018-02-01
Machines are a key element in the production system and their failure causes irreparable effects in terms of cost and time. In this paper, a new multi-objective mathematical model for dynamic cellular manufacturing system (DCMS) is provided with consideration of machine reliability and alternative process routes. In this dynamic model, we attempt to resolve the problem of integrated family (part/machine cell) formation as well as the operators' assignment to the cells. The first objective minimizes the costs associated with the DCMS. The second objective optimizes the labor utilization and, finally, a minimum value of the variance of workload between different cells is obtained by the third objective function. Due to the NP-hard nature of the cellular manufacturing problem, the problem is initially validated by the GAMS software in small-sized problems, and then the model is solved by two well-known meta-heuristic methods including non-dominated sorting genetic algorithm and multi-objective particle swarm optimization in large-scaled problems. Finally, the results of the two algorithms are compared with respect to five different comparison metrics.
Lin, Boli; Chen, Weijian; Ruan, Lei; Chen, Yongchun; Zhong, Ming; Zhuge, Qichuan; Fan, Liang Hao; Zhao, Bing; Yang, Yunjun
2016-01-01
Objectives Ruptured anterior communicating artery (ACoA) aneurysms occur more frequently in men. The purpose of the study was to investigate sex difference in aneurysm morphologies and clinical outcomes in patients with ruptured ACoA aneurysms. Setting A tertiary referral hospital. Participants A total of 574 consecutive patients with ACoA aneurysms were admitted to our hospital from December 2007 to February 2015. In all, 474 patients (257 men and 217 women) with ruptured ACoA aneurysms were included in the study. Main outcome measures Aneurysm morphologies were measured using computed tomographic angiography and clinical outcomes were measured with Glasgow coma score at discharge. Results The aneurysm sizes (p=0.001), aneurysm heights (p=0.011), size ratios (p<0.001), flow angles (p=0.047) and vessel angles (p=0.046) were larger in the male patients than in the females. The female patients more often had larger vessel sizes (p=0.002). Multivariate logistic analysis revealed that significant differences in aneurysm morphologies between men and women were aneurysm size (OR 1.1, 95% CI 1.0 to 1.3; p=0.036), aneurysm height (OR 0.8, 95% CI 0. to 0.9; p=0.006) and size ratio (OR 1.4, 95% CI 0.5 to 1.7; p=0.001). There were no statistically significant differences in the outcomes between men and women (OR 1.0, 95% CI 0.6 to 1.7, p=0.857). Conclusions The men were independently associated with larger aneurysm sizes, greater aneurysm heights and larger size ratios. Sex was not a risk factor for poor outcome in patients with ruptured ACoA aneurysms. PMID:27084272
An Evaluation of Database Solutions to Spatial Object Association
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kumar, V S; Kurc, T; Saltz, J
2008-06-24
Object association is a common problem encountered in many applications. Spatial object association, also referred to as crossmatch of spatial datasets, is the problem of identifying and comparing objects in two datasets based on their positions in a common spatial coordinate system--one of the datasets may correspond to a catalog of objects observed over time in a multi-dimensional domain; the other dataset may consist of objects observed in a snapshot of the domain at a time point. The use of database management systems to the solve the object association problem provides portability across different platforms and also greater flexibility. Increasingmore » dataset sizes in today's applications, however, have made object association a data/compute-intensive problem that requires targeted optimizations for efficient execution. In this work, we investigate how database-based crossmatch algorithms can be deployed on different database system architectures and evaluate the deployments to understand the impact of architectural choices on crossmatch performance and associated trade-offs. We investigate the execution of two crossmatch algorithms on (1) a parallel database system with active disk style processing capabilities, (2) a high-throughput network database (MySQL Cluster), and (3) shared-nothing databases with replication. We have conducted our study in the context of a large-scale astronomy application with real use-case scenarios.« less
NASA Astrophysics Data System (ADS)
Zatarain Salazar, Jazmin; Reed, Patrick M.; Quinn, Julianne D.; Giuliani, Matteo; Castelletti, Andrea
2017-11-01
Reservoir operations are central to our ability to manage river basin systems serving conflicting multi-sectoral demands under increasingly uncertain futures. These challenges motivate the need for new solution strategies capable of effectively and efficiently discovering the multi-sectoral tradeoffs that are inherent to alternative reservoir operation policies. Evolutionary many-objective direct policy search (EMODPS) is gaining importance in this context due to its capability of addressing multiple objectives and its flexibility in incorporating multiple sources of uncertainties. This simulation-optimization framework has high potential for addressing the complexities of water resources management, and it can benefit from current advances in parallel computing and meta-heuristics. This study contributes a diagnostic assessment of state-of-the-art parallel strategies for the auto-adaptive Borg Multi Objective Evolutionary Algorithm (MOEA) to support EMODPS. Our analysis focuses on the Lower Susquehanna River Basin (LSRB) system where multiple sectoral demands from hydropower production, urban water supply, recreation and environmental flows need to be balanced. Using EMODPS with different parallel configurations of the Borg MOEA, we optimize operating policies over different size ensembles of synthetic streamflows and evaporation rates. As we increase the ensemble size, we increase the statistical fidelity of our objective function evaluations at the cost of higher computational demands. This study demonstrates how to overcome the mathematical and computational barriers associated with capturing uncertainties in stochastic multiobjective reservoir control optimization, where parallel algorithmic search serves to reduce the wall-clock time in discovering high quality representations of key operational tradeoffs. Our results show that emerging self-adaptive parallelization schemes exploiting cooperative search populations are crucial. Such strategies provide a promising new set of tools for effectively balancing exploration, uncertainty, and computational demands when using EMODPS.
Stellar systems in the direction of the Hickson Compact Group 44. I. Low surface brightness galaxies
NASA Astrophysics Data System (ADS)
Smith Castelli, A. V.; Faifer, F. R.; Escudero, C. G.
2016-11-01
Context. In spite of the numerous studies of low-luminosity galaxies in different environments, there is still no consensus about their formation scenario. In particular, a large number of galaxies displaying extremely low-surface brightnesses have been detected in the last year, and the nature of these objects is under discussion. Aims: In this paper we report the detection of two extended low-surface brightness (LSB) objects (μeffg' ≃ 27 mag) found, in projection, next to NGC 3193 and in the zone of the Hickson Compact Group (HCG) 44, respectively. Methods: We analyzed deep, high-quality, GEMINI-GMOS images with ELLIPSE within IRAF in order to obtain their brightness profiles and structural parameters. We also searched for the presence of globular clusters (GC) in these fields. Results: We have found that, if these LSB galaxies were at the distances of NGC 3193 and HCG 44, they would show sizes and luminosities similar to those of the ultra-diffuse galaxies (UDGs) found in the Coma cluster and other associations. In that case, their sizes would be rather larger than those displayed by the Local Group dwarf spheroidal (dSph) galaxies. We have detected a few unresolved sources in the sky zone occupied by these galaxies showing colors and brightnesses typical of blue globular clusters. Conclusions: From the comparison of the properties of the galaxies presented in this work with those of similar objects reported in the literature, we have found that LSB galaxies display sizes covering a quite extended continous range (reff 0.3-4.5 kpc), in contrast to "normal" early-type galaxies, which show reff 1.0 kpc with a low dispersion. This fact might point to different formation processes for both types of galaxies.
Measuring lip force by oral screens. Part 1: Importance of screen size and individual variability.
Wertsén, Madeleine; Stenberg, Manne
2017-06-01
To reduce drooling and facilitate food transport in rehabilitation of patients with oral motor dysfunction, lip force can be trained using an oral screen. Longitudinal studies evaluating the effect of training require objective methods. The aim of this study was to evaluate a method for measuring lip strength, to investigate normal values and fluctuation of lip force in healthy adults on 1 occasion and over time, to study how the size of the screen affects the force, to evaluate the most appropriate measure of reliability, and to identify force performed in relation to gender. Three different sizes of oral screens were used to measure the lip force for 24 healthy adults on 3 different occasions, during a period of 6 months, using an apparatus based on strain gauge. The maximum lip force as evaluated with this method depends on the area of the screen size. By calculating the projected area of the screen, the lip force could be normalized to an oral screen pressure quantity expressed in kPa, which can be used for comparing measurements from screens with different sizes. Both the mean value and standard deviation were shown to vary between individuals. The study showed no differences regarding gender and only small variation with age. Normal variation over time (months) may be up to 3 times greater than the standard error of measurement at a certain occasion. The lip force increases in relation to the projected area of the screen. No general standard deviation can be assigned to the method and all measurements should be analyzed individually based on oral screen pressure to compensate for different screen sizes.
Memory versus perception of body size in patients with anorexia nervosa and healthy controls.
Øverås, Maria; Kapstad, Hilde; Brunborg, Cathrine; Landrø, Nils Inge; Lask, Bryan
2014-03-01
The objective of this study was to compare body size estimation based on memory versus perception, in patients with anorexia nervosa (AN) and healthy controls, adjusting for possible confounders. Seventy-one women (AN: 37, controls: 35), aged 14-29 years, were assessed with a computerized body size estimation morphing program. Information was gathered on depression, anxiety, time since last meal, weight and height. Results showed that patients overestimated their body size significantly more than controls, both in the memory and perception condition. Further, patients overestimated their body size significantly more when estimation was based on perception than memory. When controlling for anxiety, the difference between patients and controls no longer reached significance. None of the other confounders contributed significantly to the model. The results suggest that anxiety plays a role in overestimation of body size in AN. This finding might inform treatment, suggesting that more focus should be aimed at the underlying anxiety. Copyright © 2014 John Wiley & Sons, Ltd and Eating Disorders Association.
Pupil Size Tracks Attentional Performance In Attention-Deficit/Hyperactivity Disorder.
Wainstein, G; Rojas-Líbano, D; Crossley, N A; Carrasco, X; Aboitiz, F; Ossandón, T
2017-08-15
Attention-deficit/hyperactivity disorder (ADHD) diagnosis is based on reported symptoms, which carries the potential risk of over- or under-diagnosis. A biological marker that helps to objectively define the disorder, providing information about its pathophysiology, is needed. A promising marker of cognitive states in humans is pupil size, which reflects the activity of an 'arousal' network, related to the norepinephrine system. We monitored pupil size from ADHD and control subjects, during a visuo-spatial working memory task. A sub group of ADHD children performed the task twice, with and without methylphenidate, a norepinephrine-dopamine reuptake inhibitor. Off-medication patients showed a decreased pupil diameter during the task. This difference was no longer present when patients were on-medication. Pupil size correlated with the subjects' performance and reaction time variability, two vastly studied indicators of attention. Furthermore, this effect was modulated by medication. Through pupil size, we provide evidence of an involvement of the noradrenergic system during an attentional task. Our results suggest that pupil size could serve as a biomarker in ADHD.
Tufarelli, Vincenzo; Desantis, Salvatore; Zizza, Sara; Laudadio, Vito
2010-10-01
A review of past literature revealed inconsistencies in recommended feed particle size for optimal growth and productive performance of rabbits. Changing diet formulation and subsequent processing conditions may improve pellet texture and potentially affect rabbit performance. In the current study, two isoenergetic and isonitrogenous pelleted diets were formulated, which varied in the particle size of the concentrates (2 and 8 mm, respectively). The objective was to evaluate the effect of different particle sizes of compound diets on performance, nutrient utilisation, gut morphology, and carcass characteristics of fattening Italian White breed rabbits. The finely ground diet led to a significant improvement in feed efficiency and apparent digestibility of crude protein, ether extract, crude fibre and NDF, without any negative effect on gut morphology. Furthermore, a smaller particle size of concentrates in pelleted diets improved carcass traits. Meat colour parameters showed significant differences in longissimus lumborum and biceps femoris due to dietary treatments, but in both muscles pH values 1 h and 24 h after slaughter remained unchanged. It is concluded that a finely ground pelleted diet can be used to improve growth performance of rabbits without affecting carcass parameters.
An Object-Independent ENZ Metamaterial-Based Wideband Electromagnetic Cloak
Islam, Sikder Sunbeam; Faruque, Mohammad Rashed Iqbal; Islam, Mohammad Tariqul
2016-01-01
A new, metamaterial-based electromagnetic cloaking operation is proposed in this study. The metamaterial exhibits a sharp transmittance in the C-band of the microwave spectrum with negative effective property of permittivity at that frequency. Two metal arms were placed on an FR-4 substrate to construct a double-split-square shape structure. The size of the resonator was maintained to achieve the effective medium property of the metamaterial. Full wave numerical simulation was performed to extract the reflection and transmission coefficients for the unit cell. Later on, a single layer square-shaped cloak was designed using the proposed metamaterial unit cell. The cloak hides a metal cylinder electromagnetically, where the material exhibits epsilon-near-zero (ENZ) property. Cloaking operation was demonstrated adopting the scattering-reduction technique. The measured result was provided to validate the characteristics of the metamaterial and the cloak. Some object size- and shape-based analyses were performed with the cloak, and a common cloaking region was revealed over more than 900 MHz in the C-band for the different objects. PMID:27634456
An Object-Independent ENZ Metamaterial-Based Wideband Electromagnetic Cloak.
Islam, Sikder Sunbeam; Faruque, Mohammad Rashed Iqbal; Islam, Mohammad Tariqul
2016-09-16
A new, metamaterial-based electromagnetic cloaking operation is proposed in this study. The metamaterial exhibits a sharp transmittance in the C-band of the microwave spectrum with negative effective property of permittivity at that frequency. Two metal arms were placed on an FR-4 substrate to construct a double-split-square shape structure. The size of the resonator was maintained to achieve the effective medium property of the metamaterial. Full wave numerical simulation was performed to extract the reflection and transmission coefficients for the unit cell. Later on, a single layer square-shaped cloak was designed using the proposed metamaterial unit cell. The cloak hides a metal cylinder electromagnetically, where the material exhibits epsilon-near-zero (ENZ) property. Cloaking operation was demonstrated adopting the scattering-reduction technique. The measured result was provided to validate the characteristics of the metamaterial and the cloak. Some object size- and shape-based analyses were performed with the cloak, and a common cloaking region was revealed over more than 900 MHz in the C-band for the different objects.
Berkeley UXO Discriminator (BUD)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gasperikova, Erika; Smith, J. Torquil; Morrison, H. Frank
2007-01-01
The Berkeley UXO Discriminator (BUD) is an optimally designed active electromagnetic system that not only detects but also characterizes UXO. The system incorporates three orthogonal transmitters and eight pairs of differenced receivers. it has two modes of operation: (1) search mode, in which BUD moves along a profile and exclusively detects targets in its vicinity, providing target depth and horizontal location, and (2) discrimination mode, in which BUD, stationary above a target, from a single position, determines three discriminating polarizability responses together with the object location and orientation. The performance of the system is governed by a target size-depth curve.more » Maximum detection depth is 1.5 m. While UXO objects have a single major polarizability coincident with the long axis of the object and two equal transverse polarizabilities, scrap metal has three different principal polarizabilities. The results clearly show that there are very clear distinctions between symmetric intact UXO and irregular scrap metal, and that BUD can resolve the intrinsic polarizabilities of the target. The field survey at the Yuma Proving Ground in Arizona showed excellent results within the predicted size-depth range.« less
Fernández-Carrobles, M. Milagro; Tadeo, Irene; Bueno, Gloria; Noguera, Rosa; Déniz, Oscar; Salido, Jesús; García-Rojo, Marcial
2013-01-01
Given that angiogenesis and lymphangiogenesis are strongly related to prognosis in neoplastic and other pathologies and that many methods exist that provide different results, we aim to construct a morphometric tool allowing us to measure different aspects of the shape and size of vascular vessels in a complete and accurate way. The developed tool presented is based on vessel closing which is an essential property to properly characterize the size and the shape of vascular and lymphatic vessels. The method is fast and accurate improving existing tools for angiogenesis analysis. The tool also improves the accuracy of vascular density measurements, since the set of endothelial cells forming a vessel is considered as a single object. PMID:24489494
Apparent minification in an imaging display under reduced viewing conditions.
Meehan, J W
1993-01-01
When extended outdoor scenes are imaged with magnification of 1 in optical, electronic, or computer-generated displays, scene features appear smaller and farther than in direct view. This has been shown to occur in various periscopic and camera-viewfinder displays outdoors in daylight. In four experiments it was found that apparent minification of the size of a planar object at a distance of 3-9 m indoors occurs in the viewfinder display of an SLR camera both in good light and in darkness with only the luminous object visible. The effect is robust and survives changes in the relationship between object luminance in the display and in direct view and occurs in the dark when subjects have no prior knowledge of room dimensions, object size or object distance. The results of a fifth experiment suggest that the effect is an instance of reduced visual size constancy consequent on elimination of cues for size, which include those for distance.
Bivolarova, M; Ondráček, J; Melikov, A; Ždímal, V
2017-11-01
The study investigated the separate and combined effects of ventilation rate, free convection flow produced by a thermal manikin, and the presence of objects on the distribution of tracer gas and particles in indoor air. The concentration of aerosol particles and tracer gas was measured in a test room with mixing ventilation. Three layouts were arranged: an empty room, an office room with an occupant sitting in front of a table, and a single-bed hospital room. The room occupant was simulated by a thermal manikin. Monodisperse particles of three sizes (0.07, 0.7, and 3.5 μm) and nitrous oxide tracer gas were generated simultaneously at the same location in the room. The particles and gas concentrations were measured in the bulk room air, in the breathing zone of the manikin, and in the exhaust air. Within the breathing zone of the sitting occupant, the tracer gas emerged as reliable predictor for the exposure to all different-sized test particles. A change in the ventilation rate did not affect the difference in concentration distribution between tracer gas and larger particle sizes. Increasing the room surface area did not influence the similarity in the dispersion of the aerosol particles and the tracer gas. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Liu, Kaizhan; Ye, Yunming; Li, Xutao; Li, Yan
2018-04-01
In recent years Convolutional Neural Network (CNN) has been widely used in computer vision field and makes great progress in lots of contents like object detection and classification. Even so, combining Convolutional Neural Network, which means making multiple CNN frameworks working synchronously and sharing their output information, could figure out useful message that each of them cannot provide singly. Here we introduce a method to real-time estimate speed of object by combining two CNN: YOLOv2 and FlowNet. In every frame, YOLOv2 provides object size; object location and object type while FlowNet providing the optical flow of whole image. On one hand, object size and object location help to select out the object part of optical flow image thus calculating out the average optical flow of every object. On the other hand, object type and object size help to figure out the relationship between optical flow and true speed by means of optics theory and priori knowledge. Therefore, with these two key information, speed of object can be estimated. This method manages to estimate multiple objects at real-time speed by only using a normal camera even in moving status, whose error is acceptable in most application fields like manless driving or robot vision.
Methods for obtaining true particle size distributions from cross section measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Lord, Kristina Alyse
2013-01-01
Sectioning methods are frequently used to measure grain sizes in materials. These methods do not provide accurate grain sizes for two reasons. First, the sizes of features observed on random sections are always smaller than the true sizes of solid spherical shaped objects, as noted by Wicksell [1]. This is the case because the section very rarely passes through the center of solid spherical shaped objects randomly dispersed throughout a material. The sizes of features observed on random sections are inversely related to the distance of the center of the solid object from the section [1]. Second, on a planemore » section through the solid material, larger sized features are more frequently observed than smaller ones due to the larger probability for a section to come into contact with the larger sized portion of the spheres than the smaller sized portion. As a result, it is necessary to find a method that takes into account these reasons for inaccurate particle size measurements, while providing a correction factor for accurately determining true particle size measurements. I present a method for deducing true grain size distributions from those determined from specimen cross sections, either by measurement of equivalent grain diameters or linear intercepts.« less
Papadatou, Eleni; Del Águila-Carrasco, Antonio J; Esteve-Taboada, José J; Madrid-Costa, David; Cerviño-Expósito, Alejandro
2017-01-01
To analytically assess the effect of pupil size upon the refractive power distributions of different designs of multifocal contact lenses. Two multifocal contact lenses of center-near design and one multifocal contact lens of center-distance design were used in this study. Their power profiles were measured using the NIMO TR1504 device (LAMBDA-X, Belgium). Based on their power profiles, the power distribution was assessed as a function of pupil size. For the high addition lenses, the resulting refractive power as a function of viewing distance (far, intermediate, and near) and pupil size was also analyzed. The power distribution of the lenses was affected by pupil size differently. One of the lenses showed a significant spread in refractive power distribution, from about -3 D to 0 D. Generally, the power distribution of the lenses expanded as the pupil diameter became greater. The surface of the lens dedicated for each distance varied substantially with the design of the lens. In an experimental basis, our results show how the lenses power distribution is affected by the pupil size and underlined the necessity of careful evaluation of the patient's visual needs and the optical properties of a multifocal contact lens for achieving the optimal visual outcome.
[Changes in shape and size of the foot during pregnancy].
Wetz, H H; Hentschel, J; Drerup, B; Kiesel, L; Osada, N; Veltmann, U
2006-11-01
Many women report an increase in foot size during their pregnancy. Our objective was to verify this anecdotal evidence. In an initial survey of 21 mothers in 2 Münster nursery schools we found a tendency towards an increase in foot size during pregnancy. We therefore developed a measuring system to measure changes in foot length, width, height and volume. A total of 40 women recruited from the antenatal clinic of the University Hospital of Münster and a participating practice were seen three times during their pregnancy. The results were analysed using the Wilcoxon test. We found a statistically significant increase in foot length, width and volume, whereas foot height decreased slightly. This difference was, however, not significant. Especially in diabetic women with polyneuropathy it is important to pay attention to shoe size to prevent pressure sores.
NASA Astrophysics Data System (ADS)
Odert, Petra; Lammer, Helmut; Erkaev, Nikolai V.; Nikolaou, Athanasia; Lichtenegger, Herbert I. M.; Johnstone, Colin P.; Kislyakova, Kristina G.; Leitzinger, Martin; Tosi, Nicola
2017-04-01
Planetary embryos form larger planetary objects via collisions. Such Moon- to Mars-sized bodies can have magma oceans. During the solidification of their magma oceans planetary embryos may therefore degas significant amounts of their volatiles, forming H2O/CO2 dominated steam atmospheres. Such atmospheres may escape efficiently due to the low gravity of these objects and the high EUV emission of the young host star. Planets forming from such building blocks could therefore be drier than expected. We model the energy-limited outflow of hydrogen which is able to drag along heavier species such as O and CO2. We take into account different stellar EUV evolution tracks to investigate the loss of steam atmospheres from Mars-sized planetary embryos at different orbital distances. We find that the estimated envelopes are typically lost within a few to a few tens of Myr. Moreover, we address the influence on protoplanet evolution using Venus as an example. We investigate different early evolution scenarios and constrain realistic cases by comparing modeled noble gas isotope ratios with presently observed ones. We are able to reproduce current ratios by assuming either a pure steam atmosphere or a mixture with accreted hydrogen from the protoplanetary nebula. Despite being able to find solutions for different parameter combinations, our results favor a low-activity Sun with possibly a small amount of residual H from the protoplanetary nebula. In other cases too much CO2 is lost during evolution, which is inconsistent with Venus' present atmosphere. A critical issue is likely the time at which the initial steam atmosphere is outgassed.
Analogical reasoning in amazons.
Obozova, Tanya; Smirnova, Anna; Zorina, Zoya; Wasserman, Edward
2015-11-01
Two juvenile orange-winged amazons (Amazona amazonica) were initially trained to match visual stimuli by color, shape, and number of items, but not by size. After learning these three identity matching-to-sample tasks, the parrots transferred discriminative responding to new stimuli from the same categories that had been used in training (other colors, shapes, and numbers of items) as well as to stimuli from a different category (stimuli varying in size). In the critical testing phase, both parrots exhibited reliable relational matching-to-sample (RMTS) behavior, suggesting that they perceived and compared the relationship between objects in the sample stimulus pair to the relationship between objects in the comparison stimulus pairs, even though no physical matches were possible between items in the sample and comparison pairs. The parrots spontaneously exhibited this higher-order relational responding without having ever before been trained on RMTS tasks, therefore joining apes and crows in displaying this abstract cognitive behavior.
NASA Astrophysics Data System (ADS)
Zhao, Yuchen; Zemmamouche, Redouane; Vandenrijt, Jean-François; Georges, Marc P.
2018-05-01
A combination of digital holographic interferometry (DHI) and digital speckle photography (DSP) allows in-plane and out-of-plane displacement measurement between two states of an object. The former can be determined by correlating the two speckle patterns whereas the latter is given by the phase difference obtained from DHI. We show that the amplitude of numerically reconstructed object wavefront obtained from Fresnel in-line digital holography (DH), in combination with phase shifting techniques, can be used as speckle patterns in DSP. The accuracy of in-plane measurement is improved after correcting the phase errors induced by reference wave during reconstruction process. Furthermore, unlike conventional imaging system, Fresnel DH offers the possibility to resize the pixel size of speckle patterns situated on the reconstruction plane under the same optical configuration simply by zero-padding the hologram. The flexibility of speckle size adjustment in Fresnel DH ensures the accuracy of estimation result using DSP.
Survival Processing Enhances Visual Search Efficiency.
Cho, Kit W
2018-05-01
Words rated for their survival relevance are remembered better than when rated using other well-known memory mnemonics. This finding, which is known as the survival advantage effect and has been replicated in many studies, suggests that our memory systems are molded by natural selection pressures. In two experiments, the present study used a visual search task to examine whether there is likewise a survival advantage for our visual systems. Participants rated words for their survival relevance or for their pleasantness before locating that object's picture in a search array with 8 or 16 objects. Although there was no difference in search times among the two rating scenarios when set size was 8, survival processing reduced visual search times when set size was 16. These findings reflect a search efficiency effect and suggest that similar to our memory systems, our visual systems are also tuned toward self-preservation.
Immobilization thresholds of electrofishing relative to fish size
Dolan, C.R.; Miranda, L.E.
2003-01-01
Fish size and electrical waveforms have frequently been associated with variation in electrofishing effectiveness. Under controlled laboratory conditions, we measured the electrical power required by five electrical waveforms to immobilize eight fish species of diverse sizes and shapes. Fish size was indexed by total body length, surface area, volume, and weight; shape was indexed by the ratio of body length to body depth. Our objectives were to identify immobilization thresholds, elucidate the descriptors of fish size that were best associated with those immobilization thresholds, and determine whether the vulnerability of a species relative to other species remained constant across electrical treatments. The results confirmed that fish size is a key variable controlling the immobilization threshold and further suggested that the size descriptor best related to immobilization is fish volume. The peak power needed to immobilize fish decreased rapidly with increasing fish volume in small fish but decreased slowly for fish larger than 75-100 cm 3. Furthermore, when we controlled for size and shape, different waveforms did not favor particular species, possibly because of the overwhelming effect of body size. Many of the immobilization inconsistencies previously attributed to species might simply represent the effect of disparities in body size.
Uncertainty in Population Estimates for Endangered Animals and Improving the Recovery Process.
Haines, Aaron M; Zak, Matthew; Hammond, Katie; Scott, J Michael; Goble, Dale D; Rachlow, Janet L
2013-08-13
United States recovery plans contain biological information for a species listed under the Endangered Species Act and specify recovery criteria to provide basis for species recovery. The objective of our study was to evaluate whether recovery plans provide uncertainty (e.g., variance) with estimates of population size. We reviewed all finalized recovery plans for listed terrestrial vertebrate species to record the following data: (1) if a current population size was given, (2) if a measure of uncertainty or variance was associated with current estimates of population size and (3) if population size was stipulated for recovery. We found that 59% of completed recovery plans specified a current population size, 14.5% specified a variance for the current population size estimate and 43% specified population size as a recovery criterion. More recent recovery plans reported more estimates of current population size, uncertainty and population size as a recovery criterion. Also, bird and mammal recovery plans reported more estimates of population size and uncertainty compared to reptiles and amphibians. We suggest the use of calculating minimum detectable differences to improve confidence when delisting endangered animals and we identified incentives for individuals to get involved in recovery planning to improve access to quantitative data.
Grain size of loess and paleosol samples: what are we measuring?
NASA Astrophysics Data System (ADS)
Varga, György; Kovács, János; Szalai, Zoltán; Újvári, Gábor
2017-04-01
Particle size falling into a particularly narrow range is among the most important properties of windblown mineral dust deposits. Therefore, various aspects of aeolian sedimentation and post-depositional alterations can be reconstructed only from precise grain size data. Present study is aimed at (1) reviewing grain size data obtained from different measurements, (2) discussing the major reasons for disagreements between data obtained by frequently applied particle sizing techniques, and (3) assesses the importance of particle shape in particle sizing. Grain size data of terrestrial aeolian dust deposits (loess and paleosoil) were determined by laser scattering instruments (Fritsch Analysette 22 Microtec Plus, Horiba Partica La-950 v2 and Malvern Mastersizer 3000 with a Hydro Lv unit), while particles size and shape distributions were acquired by Malvern Morphologi G3-ID. Laser scattering results reveal that the optical parameter settings of the measurements have significant effects on the grain size distributions, especially for the fine-grained fractions (<5 µm). Significant differences between the Mie and Fraunhofer approaches were found for the finest grain size fractions, while only slight discrepancies were observed for the medium to coarse silt fractions. It should be noted that the different instruments provided different grain size distributions even with the exactly same optical settings. Image analysis-based grain size data indicated underestimation of clay and fine silt fractions compared to laser measurements. The measured circle-equivalent diameter of image analysis is calculated from the acquired two-dimensional image of the particle. It is assumed that the instantaneous pulse of compressed air disperse the sedimentary particles onto the glass slide with a consistent orientation with their largest area facing to the camera. However, this is only one outcome of infinite possible projections of a three-dimensional object and it cannot be regarded as a representative one. The third (height) dimension of the particles remains unknown, so the volume-based weightings are fairly dubious in the case of platy particles. Support of the National Research, Development and Innovation Office (Hungary) under contract NKFI 120620 is gratefully acknowledged. It was additionally supported (for G. Varga) by the Bolyai János Research Scholarship of the Hungarian Academy of Sciences.
Computation of the acoustic radiation force using the finite-difference time-domain method.
Cai, Feiyan; Meng, Long; Jiang, Chunxiang; Pan, Yu; Zheng, Hairong
2010-10-01
The computational details related to calculating the acoustic radiation force on an object using a 2-D grid finite-difference time-domain method (FDTD) are presented. The method is based on propagating the stress and velocity fields through the grid and determining the energy flow with and without the object. The axial and radial acoustic radiation forces predicted by FDTD method are in excellent agreement with the results obtained by analytical evaluation of the scattering method. In particular, the results indicate that it is possible to trap the steel cylinder in the radial direction by optimizing the width of Gaussian source and the operation frequency. As the sizes of the relating objects are smaller than or comparable to wavelength, the algorithm presented here can be easily extended to 3-D and include torque computation algorithms, thus providing a highly flexible and universally usable computation engine.
Plamondon, André; Larivière, Christian; Delisle, Alain; Denis, Denys; Gagnon, Denis
2012-01-01
The objective of this study was to measure the effect size of three important factors in manual material handling, namely expertise, lifting height and weight lifted. The effect of expertise was evaluated by contrasting 15 expert and 15 novice handlers, the effect of the weight lifted with a 15-kg box and a 23-kg box and the effect of lifting height with two different box heights: ground level and a 32 cm height. The task consisted of transferring a series of boxes from a conveyor to a hand trolley. Lifting height and weight lifted had more effect size than expertise on external back loading variables (moments) while expertise had low impact. On the other hand, expertise showed a significant effect of posture variables on the lumbar spine and knees. All three factors are important, but for a reduction of external back loading, the focus should be on the lifting height and weight lifted. The objective was to measure the effect size of three important factors in a transfer of boxes from a conveyor to a hand trolley. Lifting height and weight lifted had more effect size than expertise on external back loading variables but expertise was a major determinant in back posture.
Giordano, Bruno L; McAdams, Stephen
2006-02-01
Identification of the material of struck objects of variable size was investigated. Previous studies on this issue assumed recognition to be based on acoustical measures of damping. This assumption was tested, comparing the power of a damping measure in explaining identification data with that of several other acoustical descriptors. Listeners' performance was perfect with respect to gross material categories (steel-glass and wood-plexiglass) comprising materials of vastly different mechanical properties. Impaired performance was observed for materials within the same gross category, identification being based on the size of the objects alone. The damping descriptor accounted for the identification of the gross categories. However other descriptors such as signal duration explained the results equally well. Materials within the same gross category were identified mainly on the basis of signal frequency. Overall poor support for the relevance of damping to material perception was found. An analysis of the acoustical support for perfect material identification was carried out. Sufficient acoustical information for perfect performance was found. Thus, procedural biases for the origin of the effects of size could be discarded, pointing toward their cognitive, rather than methodological nature. Identification performance was explained in terms of the regularities of the everyday acoustical environment.
Granular media in the context of small bodies
NASA Astrophysics Data System (ADS)
Tancredi, G.
2014-07-01
Granular materials of different particle sizes are present on the surface and the interior of several atmosphereless Solar System bodies. The presence of very fine particles on the surface of the Moon, the so-called regolith, was confirmed by the Apollo astronauts. From the polarimetric observations and phase angle curves, it is possible to indirectly infer the presence of fine particles on the surfaces of asteroids and planetary satellites. More recently, the visit of spacecraft to several asteroids and comets has provided us with close pictures of the surface, where particles of a wide size range from cm to hundreds of meters have been directly observed. The presence of even finer particles on the visited bodies can also be inferred from image analysis. Solar System bodies smaller than a few hundred km may have a variety of internal structures: monolithic single bodies, objects with internal fractures, rubble piles maintained as a single object by self-gravity, etc. After the visit of the small asteroid Itokawa, it has been speculated that ''some small asteroids appear to be clumps of gravel glued by a very weak gravity field'' (Asphaug 2007). We still do not know the internal structure of these rubble piles and the size distribution of the interior constituents, but these clumps could have several million meter-sized boulders inside. There are several pieces of evidence that many asteroids are agglomerates of small components, like: - Rotation periods for small asteroids - Tidal disruption of asteroids and comets when they enter the Roche's limit of a massive object - The existence of crater chains like the ones observed in Ganymede - Low density estimates (< 2 gr/cm^3) for many asteroids like Mathilde It has been proposed that several typical processes of granular materials (such as: the size segregation of boulders on Itokawa, the displacement of boulders on Eros, the ejection of dust clouds after impacts) can explain some features observed on these bodies. We review the numerical and experimental studies on granular materials with relevance to the understanding of the physical processes on the interior and the surfaces of minor bodies of the Solar System. In particular, we compare the different codes in use to perform numerical simulations of the physical evolution of these objects. We highlight results of these simulations. Some groups have been involved in laboratory experiments on granular material trying to reproduce the conditions in space: vacuum and low gravity. We describe the experimental set-ups and some results of these experiments. Some open problems and future line of work in this field will be presented.
2017-07-19
NASA's New Horizons team trained mobile telescopes on an unnamed star (circled) from a remote area of Argentina on July 17, 2017. A Kuiper Belt object 4.1 billion miles from Earth -- known as 2014 MU69 -- briefly blocked the light from the background star, in what's known as an occultation. The time difference between frames is 200 milliseconds, or 0.2 seconds. This data will help scientists better measure the shape, size and environment around the object. The New Horizons spacecraft will fly by this ancient relic of solar system formation on Jan. 1, 2019. It will be the most distant object ever explored by a spacecraft. A video is available at https://photojournal.jpl.nasa.gov/catalog/PIA21865
Integration across Time Determines Path Deviation Discrimination for Moving Objects
Whitaker, David; Levi, Dennis M.; Kennedy, Graeme J.
2008-01-01
Background Human vision is vital in determining our interaction with the outside world. In this study we characterize our ability to judge changes in the direction of motion of objects–a common task which can allow us either to intercept moving objects, or else avoid them if they pose a threat. Methodology/Principal Findings Observers were presented with objects which moved across a computer monitor on a linear path until the midline, at which point they changed their direction of motion, and observers were required to judge the direction of change. In keeping with the variety of objects we encounter in the real world, we varied characteristics of the moving stimuli such as velocity, extent of motion path and the object size. Furthermore, we compared performance for moving objects with the ability of observers to detect a deviation in a line which formed the static trace of the motion path, since it has been suggested that a form of static memory trace may form the basis for these types of judgment. The static line judgments were well described by a ‘scale invariant’ model in which any two stimuli which possess the same two-dimensional geometry (length/width) result in the same level of performance. Performance for the moving objects was entirely different. Irrespective of the path length, object size or velocity of motion, path deviation thresholds depended simply upon the duration of the motion path in seconds. Conclusions/Significance Human vision has long been known to integrate information across space in order to solve spatial tasks such as judgment of orientation or position. Here we demonstrate an intriguing mechanism which integrates direction information across time in order to optimize the judgment of path deviation for moving objects. PMID:18414653
Performance of Granular Starch with Controlled Pore Size during Hydrolysis with Digestive Enzymes.
Benavent-Gil, Yaiza; Rosell, Cristina M
2017-12-01
Studies on porous starch have been directed to explore different industrial applications as bio-adsorbents of a variety of compounds. However, the analysis of starch digestibility is essential for food application. The objective of this study was to determine the impact of porous structure on in vitro starch digestibility. Porous starches were obtained using a range of concentrations of amyloglucosidase (AMG), α-amylase (AM), cyclodextrin-glycosyltransferase (CGTase) or branching enzyme (BE). Porous starches exhibited major content of digestible starch (DS) that increased with the intensity of the enzymatic treatment, and very low amount of resistant starch (RS). Porous starches behaved differently during in vitro hydrolysis depending on their enzymatic treatment. AMG was the unique treatment that increased the digestive amylolysis and estimated glycemic index, whereas AM, CGTase and BE reduced them. A significant relationship was found between the pore size and the severity of the amylolysis, suggesting that a specific pore size is required for the accessibility of the digestive amylase. Therefore, pore size in the starch surface was a limiting factor for digestion of starch granules.
A simple but powerful theory of the moon illusion.
Baird, J C; Wagner, M; Fuld, K
1990-08-01
Modification of Restle's theory (1970) explains the moon illusion and related phenomena on the basis of three principles: (1) The apparent sizes of objects are their perceived visual angles. (2) The apparent size of the moon is determined by the ratio of the angular extent of the moon relative to the extents subtended by objects composing the surrounding context, such as the sky and things on the ground. (3) The visual extents subtended by common objects of a constant physical size decrease systematically with increasing distance from the observer. Further development of this theory requires specification of both the components of the surrounding context and their relative importance in determining the apparent size and distance of the moon.
Hospital ownership, decisions on supervisory board characteristics, and financial performance.
Kuntz, Ludwig; Pulm, Jannis; Wittland, Michael
2016-01-01
Dynamic and complex transformations in the hospital market increase the relevance of good corporate governance. However, hospital performance and the characteristics of supervisory boards differ depending on ownership. The question therefore arises whether hospital owners can influence performance by addressing supervisory board characteristics. The objective of this study is to explain differences in the financial performance of hospitals with regard to ownership by studying the size and composition of supervisory boards. The AMADEUS database was used to collect information on hospital financial performance in 2009 and 2010. Business and quality reports, hospital websites, and data from health insurer were used to obtain information on hospital and board characteristics. The resulting sample consisted of 175 German hospital corporations. We utilized ANOVA and regression analysis to test a mediation hypothesis that investigated whether decisions regarding board size and composition were associated with financial performance and could explain performance differences. Financial performance and board size and composition depend on ownership. An increase in board size and greater politician participation were negatively associated with all five tested measures of financial performance. Furthermore, an increase in physician participation was positively associated with one dimension of financial performance, whereas one negative relationship was identified for nurse and economist participation. For clerics, no associations were found. Decisions concerning board size and composition are important as they relate to hospital financial performance. We contribute to existing research by showing that, in addition to board size and physician participation, the participation of other professionals can also influence financial performance.
Great bowerbirds create theaters with forced perspective when seen by their audience.
Endler, John A; Endler, Lorna C; Doerr, Natalie R
2010-09-28
Birds in the infraorder Corvida [1] (ravens, jays, bowerbirds) are renowned for their cognitive abilities [2-4], which include advanced problem solving with spatial inference [4-8], tool use and complex constructions [7-10], and bowerbird cognitive ability is associated with mating success [11]. Great bowerbird males construct bowers with a long avenue from within which females view the male displaying over his bower court [10]. This predictable audience viewpoint is a prerequisite for forced (altered) visual perspective [12-14]. Males make courts with gray and white objects that increase in size with distance from the avenue entrance. This gradient creates forced visual perspective for the audience; court object visual angles subtended on the female viewer's eye are more uniform than if the objects were placed at random. Forced perspective can yield false perception of size and distance [12, 15]. After experimental reversal of their size-distance gradient, males recovered their gradients within 3 days, and there was little difference from the original after 2 wks. Variation among males in their forced-perspective quality as seen by their female audience indicates that visual perspective is available for use in mate choice, perhaps as an indicator of cognitive ability. Regardless of function, the creation and maintenance of forced visual perspective is clearly important to great bowerbirds and suggests the possibility of a previously unknown dimension of bird cognition. Copyright © 2010 Elsevier Ltd. All rights reserved.
The Effect of Rheological Properties of Foods on Bolus Characteristics After Mastication
Hwang, Junah; Bae, Jung Hyun; Kang, Si Hyun; Seo, Kyung Mook; Kim, Byong Ki; Lee, Sook Young
2012-01-01
Objective To evaluate the effects of physical properties of foods on the changes of viscosity and mass as well as the particle size distribution after mastication. Method Twenty subjects with no masticatory disorders were recruited. Six grams of four solid foods of different textures (banana, tofu, cooked-rice, cookie) were provided, and the viscosity and mass after 10, 20, and 30 cycles of mastication and just before swallowing were measured. The physical properties of foods, such as hardness, cohesiveness, and adhesiveness, were measured with a texture analyzer. Wet sieving and laser diffraction were used to determine the distribution of food particle size. Results When we measured the physical characteristics of foods, the cookie was the hardest food, and the banana exhibited marked adhesiveness. Tofu and cooked-rice exhibited a highly cohesive nature. As the number of mastication cycles increased, the masses of all foods were significantly increased (p<0.05), and the viscosity was significantly decreased in the case of banana, tofu, and cooked-rice (p<0.05). The mass and viscosity of all foods were significantly different between the foods after mastication (p<0.05). Analyzing the distribution of the particle size, that of the bolus was different between foods. However, the curves representing the particle size distribution for each food were superimposable for most subjects. Conclusion The viscosity and particle size distribution of the bolus were different between solid foods that have different physical properties. Based on this result, the mastication process and food bolus formation were affected by the physical properties of the food. PMID:23342309
Lens-Aided Multi-Angle Spectroscopy (LAMAS) Reveals Small-Scale Outflow Structure in Quasars
NASA Astrophysics Data System (ADS)
Green, Paul J.
2006-06-01
Spectral differences between lensed quasar image components are common. Since lensing is intrinsically achromatic, these differences are typically explained as the effect of either microlensing, or as light path time delays sampling intrinsic quasar spectral variability. Here we advance a novel third hypothesis: some spectral differences are due to small line-of-sight differences through quasar disk wind outflows. In particular, we propose that variable spectral differences seen only in component A of the widest separation lens SDSS J1004+4112 are due to differential absorption along the sight lines. The absorber properties required by this hypothesis are akin to known broad absorption line (BAL) outflows but must have a broader, smoother velocity profile. We interpret the observed C IV emission-line variability as further evidence for spatial fine structure transverse to the line of sight. Since outflows are likely to be rotating, such absorber fine structure can consistently explain some of the UV and X-ray variability seen in AGNs. The implications are many: (1) Spectroscopic differences in other lensed objects may be due to this ``lens-aided multi-angle spectroscopy'' (LAMAS). (2) Outflows have fine structure on size scales of arcseconds, as seen from the nucleus. (3) Assuming either broad absorption line region sizes proposed in recent wind models, or typically assumed continuum emission region sizes, LAMAS and/or variability provide broadly consistent absorber size scale estimates of ~1015 cm. (4) Very broad smooth absorption may be ubiquitous in quasar spectra, even when no obvious troughs are seen.
Photometric imaging in particle size measurement and surface visualization.
Sandler, Niklas
2011-09-30
The aim of this paper is to give an insight into photometric particle sizing approaches, which differ from the typical particle size measurement of dispersed particles. These approaches can often be advantageous especially for samples that are moist or cohesive, when dispersion of particles is difficult or sometimes impossible. The main focus of this paper is in the use of photometric stereo imaging. The technique allows the reconstruction of three-dimensional images of objects using multiple light sources in illumination. The use of photometric techniques is demonstrated in at-line measurement of granules and on-line measurement during granulation and dry milling. Also, surface visualization and roughness measurements are briefly discussed. Copyright © 2010 Elsevier B.V. All rights reserved.
Set size, individuation, and attention to shape
Cantrell, Lisa; Smith, Linda B.
2013-01-01
Much research has demonstrated a shape bias in categorizing and naming solid objects. This research has shown that when an entity is conceptualized as an individual object, adults and children attend to the object’s shape. Separate research in the domain of numerical cognition suggest that there are distinct processes for quantifying small and large sets of discrete items. This research shows that small set discrimination, comparison, and apprehension is often precise for 1–3 and sometimes 4 items; however, large numerosity representation is imprecise. Results from three experiments suggest a link between the processes for small and large number representation and the shape bias in a forced choice categorization task using naming and non-naming procedures. Experiment 1 showed that adults generalized a newly learned name for an object to new instances of the same shape only when those instances were presented in sets of less than 3 or 4. Experiment 2 showed that preschool children who were monolingual speakers of three different languages were also influenced by set size when categorizing objects in sets. Experiment 3 extended these results and showed the same effect in a non-naming task and when the novel noun was presented in a count-noun syntax frame. The results are discussed in terms of a relation between the precision of object representation and the precision of small and large number representation. PMID:23167969
USDA-ARS?s Scientific Manuscript database
Direct single trait selection within two seasonal replicates for 11 generations resulted in a 1.6 pig advantage for uterine capacity (UC) and a 3.0 advantage for ovulation rate (OR) compared to an unselected control (CO) population. Our objective was to gain insight and identify genetic loci impacte...
Technical Report from Grant Recipient - City of Redlands
DOE Office of Scientific and Technical Information (OSTI.GOV)
Giorgianni, Kathleen Margaret
2016-05-26
The goals and objectives of the HVAC upgrades are to replace equipment as old as twenty-three (23) years in five different facilities. The project will upgrade some facilities from SEER ratings of 9 to SEER ratings of 14 at a savings of 556 kilowatt hours per ton (savings depends on specific size of the system).
Jeffrey E. Ott; Robert D. Cox; Nancy L. Shaw; Beth A. Newingham; Amy C. Ganguli; Mike Pellant; Bruce A. Roundy; Dennis L. Eggett
2016-01-01
Objectives of postfire seeding in the Great Basin include reestablishment of perennial cover, suppression of exotic annual weeds, and restoration of diverse plant communities. Nonconventional seeding techniques may be required when seeding mixes of grasses, forbs, and shrubs containing seeds of different sizes. We conducted an operational-scale experiment to...
Cryogen spray cooling: Effects of droplet size and spray density on heat removal.
Pikkula, B M; Torres, J H; Tunnell, J W; Anvari, B
2001-01-01
Cryogen spray cooling (CSC) is an effective method to reduce or eliminate non-specific injury to the epidermis during laser treatment of various dermatological disorders. In previous CSC investigations, fuel injectors have been used to deliver the cryogen onto the skin surface. The objective of this study was to examine cryogen atomization and heat removal characteristics of various cryogen delivery devices. Various cryogen delivery device types including fuel injectors, atomizers, and a device currently used in clinical settings were investigated. Cryogen mass was measured at the delivery device output orifice. Cryogen droplet size profiling for various cryogen delivery devices was estimated by optically imaging the droplets in flight. Heat removal for various cryogen delivery devices was estimated over a range of spraying distances by temperature measurements in an skin phantom used in conjunction with an inverse heat conduction model. A substantial range of mass outputs were measured for the cryogen delivery devices while heat removal varied by less than a factor of two. Droplet profiling demonstrated differences in droplet size and spray density. Results of this study show that variation in heat removal by different cryogen delivery devices is modest despite the relatively large difference in cryogen mass output and droplet size. A non-linear relationship between heat removal by various devices and droplet size and spray density was observed. Copyright 2001 Wiley-Liss, Inc.
Riley, Joseph L.; Williams, Ameenah K.K.; Fillingim, Roger B.
2012-01-01
Objective Pain is a subjectively complex and universal experience. We examine research investigating ethnic group differences in experimental pain response, and factors contributing to group differences. Method We conducted a systematic literature review and analysis of studies using experimental pain stimuli to assess pain sensitivity across multiple ethnic groups. Our search covered the period from 1944-2011, and utilized the PUBMED bibliographic database; a reference source containing over 17 million citations. We calculated effect sizes, identified ethnic/racial group categories, pain stimuli and measures, and examined findings regarding biopsychosociocultural factors contributing to ethnic/racial group differences. Results We found 472 studies investigating ethnic group differences and pain. Twenty-six of these met our review inclusion criteria of investigating ethnic group differences in experimental pain. The majority of studies included comparisons between African Americans (AA) and non-Hispanic Whites (NHW). There were consistently moderate to large effect sizes for pain tolerance across multiple stimulus modalities; African Americans demonstrated lower pain tolerance. For pain threshold, findings were generally in the same direction, but effect sizes were small to moderate across ethnic groups. Limited data were available for suprathreshold pain ratings. A subset of studies comparing NHW and other ethnic groups showed a variable range of effect sizes for pain threshold and tolerance. Conclusion There are potentially important ethnic/racial group differences in experimental pain perception. Elucidating ethnic group differences, has translational merit for culturally-competent clinical care and for addressing and reducing pain treatment disparities among ethnically/racially diverse groups. PMID:22390201
Holographic particle size extraction by using Wigner-Ville distribution
NASA Astrophysics Data System (ADS)
Chuamchaitrakool, Porntip; Widjaja, Joewono; Yoshimura, Hiroyuki
2014-06-01
A new method for measuring object size from in-line holograms by using Wigner-Ville distribution (WVD) is proposed. The proposed method has advantages over conventional numerical reconstruction in that it is free from iterative process and it can extract the object size and position with only single computation of the WVD. Experimental verification of the proposed method is presented.
Neurosurgical tactile discrimination training with haptic-based virtual reality simulation.
Patel, Achal; Koshy, Nick; Ortega-Barnett, Juan; Chan, Hoi C; Kuo, Yong-Fan; Luciano, Cristian; Rizzi, Silvio; Matulyauskas, Martin; Kania, Patrick; Banerjee, Pat; Gasco, Jaime
2014-12-01
To determine if a computer-based simulation with haptic technology can help surgical trainees improve tactile discrimination using surgical instruments. Twenty junior medical students participated in the study and were randomized into two groups. Subjects in Group A participated in virtual simulation training using the ImmersiveTouch simulator (ImmersiveTouch, Inc., Chicago, IL, USA) that required differentiating the firmness of virtual spheres using tactile and kinesthetic sensation via haptic technology. Subjects in Group B did not undergo any training. With their visual fields obscured, subjects in both groups were then evaluated on their ability to use the suction and bipolar instruments to find six elastothane objects with areas ranging from 1.5 to 3.5 cm2 embedded in a urethane foam brain cavity model while relying on tactile and kinesthetic sensation only. A total of 73.3% of the subjects in Group A (simulation training) were able to find the brain cavity objects in comparison to 53.3% of the subjects in Group B (no training) (P = 0.0183). There was a statistically significant difference in the total number of Group A subjects able to find smaller brain cavity objects (size ≤ 2.5 cm2) compared to that in Group B (72.5 vs. 40%, P = 0.0032). On the other hand, no significant difference in the number of subjects able to detect larger objects (size ≧ 3 cm2) was found between Groups A and B (75 vs. 80%, P = 0.7747). Virtual computer-based simulators with integrated haptic technology may improve tactile discrimination required for microsurgical technique.
Near or far: The effect of spatial distance and vocabulary knowledge on word learning.
Axelsson, Emma L; Perry, Lynn K; Scott, Emilly J; Horst, Jessica S
2016-01-01
The current study investigated the role of spatial distance in word learning. Two-year-old children saw three novel objects named while the objects were either in close proximity to each other or spatially separated. Children were then tested on their retention for the name-object associations. Keeping the objects spatially separated from each other during naming was associated with increased retention for children with larger vocabularies. Children with a lower vocabulary size demonstrated better retention if they saw objects in close proximity to each other during naming. This demonstrates that keeping a clear view of objects during naming improves word learning for children who have already learned many words, but keeping objects within close proximal range is better for children at earlier stages of vocabulary acquisition. The effect of distance is therefore not equal across varying vocabulary sizes. The influences of visual crowding, cognitive load, and vocabulary size on word learning are discussed. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.
A POSSIBLE DIVOT IN THE SIZE DISTRIBUTION OF THE KUIPER BELT'S SCATTERING OBJECTS
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shankman, C.; Gladman, B. J.; Kaib, N.
Via joint analysis of a calibrated telescopic survey, which found scattering Kuiper Belt objects, and models of their expected orbital distribution, we explore the scattering-object (SO) size distribution. Although for D > 100 km the number of objects quickly rise as diameters decrease, we find a relative lack of smaller objects, ruling out a single power law at greater than 99% confidence. After studying traditional ''knees'' in the size distribution, we explore other formulations and find that, surprisingly, our analysis is consistent with a very sudden decrease (a divot) in the number distribution as diameters decrease below 100 km, whichmore » then rises again as a power law. Motivated by other dynamically hot populations and the Centaurs, we argue for a divot size distribution where the number of smaller objects rises again as expected via collisional equilibrium. Extrapolation yields enough kilometer-scale SOs to supply the nearby Jupiter-family comets. Our interpretation is that this divot feature is a preserved relic of the size distribution made by planetesimal formation, now ''frozen in'' to portions of the Kuiper Belt sharing a ''hot'' orbital inclination distribution, explaining several puzzles in Kuiper Belt science. Additionally, we show that to match today's SO inclination distribution, the supply source that was scattered outward must have already been vertically heated to the of order 10 Degree-Sign .« less
The Army Communications Objectives Measurement System (ACOMS): Survey Design
1988-04-01
monthly basis so that the annual sample includes sufficient Hispanics to detect at the .80 power level: (1) Year-to-year changes of 3% in item...Hispanics. The requirements are listed in terms of power level and must be translated into requisite sample sizes. The requirements are expressed as the...annual samples needed to detect certain differences at the 80% power level. Differences in both directions are to be examined, so that a two-tailed
Are All Active Galactic Nuclei Born Equal? The Silicate Dust Mineralogy Perspective
NASA Astrophysics Data System (ADS)
Li, Aigen
Dust is the cornerstone of the unification theory of active galactic nuclei (AGNs). This theory proposes that all AGNs are essentially the same object or "born equal" but viewed from different lines of sight; much of the observed diversity arises from different viewing angles toward the central engine and a dusty toroidal structure around it. When the dusty torus is viewed face-on, both the central engine and the broad-line regions can be seen directly causing objects to appear as type 1 AGNs; when the dusty torus is viewed edge- on, the anisotropic obscuration created by the torus causes objects to appear as type 2 AGNs. It is this crucial role played by dust in the unified model of AGNs that makes understanding dust properties very important in understanding AGNs. Little is known about the dust in the circumnuclear torus of AGNs. There is evidence suggesting that the size and composition of the dust in AGNs may differ substantially from that of the Galactic interstellar dust, as reflected by the flat or "gray" extinction, and the anomalous silicate emission or absorption features observed respectively in type 1 and type 2 AGNs. The silicate feature profiles of AGNs are rather diverse in peak wavelengths, widths, strengths, and band ratios of the 18 micrometer O--Si--O feature to the 9.7 micrometer Si--O feature, suggesting that the AGN silicate grains are diverse in composition and size (or probably not "born equal"). We propose a two-year project to study the size and composition of the dust in AGNs, with special attention paid to the silicate mineralogy. We will obtain constraints on the silicate composition and size by modeling the Spitzer IRS spectra of >100 AGNs of various types. We will examine whether (and how) the silicate composition and size properties vary with the properties of an AGN (e.g. type, luminosity). This research will improve our understanding of the physical properties of the dust torus and the origin of the observed silicate emission: whether it arises mainly from the torus or from the narrow line regions. We will also provide the community with "recommended" silicate opacities for AGNs of various types. This will facilitate more detailed radiative transfer modeling of the infrared spectral energy distributions of AGNs by incorporating more realistic silicate opacities. This research supports the NASA Strategic Subgoal 3C: Discover the origin, structure, evolution, and destiny of the universe.
Cho, Seung-Hyun; Tong, Haiyan; McGee, John K.; Baldauf, Richard W.; Krantz, Q. Todd; Gilmour, M. Ian
2009-01-01
Background Epidemiologic studies have reported an association between proximity to highway traffic and increased cardiopulmonary illnesses. Objectives We investigated the effect of size-fractionated particulate matter (PM), obtained at different distances from a highway, on acute cardiopulmonary toxicity in mice. Methods We collected PM for 2 weeks in July–August 2006 using a three-stage (ultrafine, < 0.1 μm; fine, 0.1–2.5 μm; coarse, 2.5–10 μm) high-volume impactor at distances of 20 m [near road (NR)] and 275 m [far road (FR)] from an interstate highway in Raleigh, North Carolina. Samples were extracted in methanol, dried, diluted in saline, and then analyzed for chemical constituents. Female CD-1 mice received either 25 or 100 μg of each size fraction via oropharyngeal aspiration. At 4 and 18 hr postexposure, mice were assessed for pulmonary responsiveness to inhaled methacholine, biomarkers of lung injury and inflammation; ex vivo cardiac pathophysiology was assessed at 18 hr only. Results Overall chemical composition between NR and FR PM was similar, although NR samples comprised larger amounts of PM, endotoxin, and certain metals than did the FR samples. Each PM size fraction showed differences in ratios of major chemical classes. Both NR and FR coarse PM produced significant pulmonary inflammation irrespective of distance, whereas both NR and FR ultrafine PM induced cardiac ischemia–reperfusion injury. Conclusions On a comparative mass basis, the coarse and ultrafine PM affected the lung and heart, respectively. We observed no significant differences in the overall toxicity end points and chemical makeup between the NR and FR PM. The results suggest that PM of different size-specific chemistry might be associated with different toxicologic mechanisms in cardiac and pulmonary tissues. PMID:20049117
NASA Astrophysics Data System (ADS)
Lejoly, Cassandra; Howell, Ellen S.; Taylor, Patrick A.; Springmann, Alessondra; Virkki, Anne; Nolan, Michael C.; Rivera-Valentin, Edgard G.; Benner, Lance A. M.; Brozovic, Marina; Giorgini, Jon D.
2017-10-01
The Near-Earth Asteroid (NEA) population ranges in size from a few meters to more than 10 kilometers. NEAs have a wide variety of taxonomic classes, surface features, and shapes, including spheroids, binary objects, contact binaries, elongated, as well as irregular bodies. Using the Arecibo Observatory planetary radar system, we have measured apparent rotation rate, radar reflectivity, apparent diameter, and radar albedos for over 350 NEAs. The radar albedo is defined as the radar cross-section divided by the geometric cross-section. If a shape model is available, the actual cross-section is known at the time of the observation. Otherwise we derive a geometric cross-section from a measured diameter. When radar imaging is available, the diameter was measured from the apparent range depth. However, when radar imaging was not available, we used the continuous wave (CW) bandwidth radar measurements in conjunction with the period of the object. The CW bandwidth provides apparent rotation rate, which, given an independent rotation measurement, such as from lightcurves, constrains the size of the object. We assumed an equatorial view unless we knew the pole orientation, which gives a lower limit on the diameter. The CW also provides the polarization ratio, which is the ratio of the SC and OC cross-sections.We confirm the trend found by Benner et al. (2008) that taxonomic types E and V have very high polarization ratios. We have obtained a larger sample and can analyze additional trends with spin, size, rotation rate, taxonomic class, polarization ratio, and radar albedo to interpret the origin of the NEAs and their dynamical processes. The distribution of radar albedo and polarization ratio at the smallest diameters (≤50 m) differs from the distribution of larger objects (>50 m), although the sample size is limited. Additionally, we find more moderate radar albedos for the smallest NEAs when compared to those with diameters 50-150 m. We will present additional trends we find in this data set.
The Reactivation of Motion influences Size Categorization in a Visuo-Haptic Illusion.
Rey, Amandine E; Dabic, Stephanie; Versace, Remy; Navarro, Jordan
2016-09-01
People simulate themselves moving when they view a picture, read a sentence, or simulate a situation that involves motion. The simulation of motion has often been studied in conceptual tasks such as language comprehension. However, most of these studies investigated the direct influence of motion simulation on tasks inducing motion. This article investigates whether a mo- tion induced by the reactivation of a dynamic picture can influence a task that did not require motion processing. In a first phase, a dynamic picture and a static picture were systematically presented with a vibrotactile stimulus (high or low frequency). The second phase of the experiment used a priming paradigm in which a vibrotactile stimulus was presented alone and followed by pictures of objects. Participants had to categorize objects as large or small relative to their typical size (simulated size). Results showed that when the target object was preceded by the vibrotactile stimulus previously associated with the dynamic picture, participants perceived all the objects as larger and categorized them more quickly when the objects were typically "large" and more slowly when the objects were typically "small." In light of embodied cognition theories, this bias in participants' perception is assumed to be caused by an induced forward motion. generated by the reactivated dynamic picture, which affects simulation of the size of the objects.
Image denoising and deblurring using multispectral data
NASA Astrophysics Data System (ADS)
Semenishchev, E. A.; Voronin, V. V.; Marchuk, V. I.
2017-05-01
Currently decision-making systems get widespread. These systems are based on the analysis video sequences and also additional data. They are volume, change size, the behavior of one or a group of objects, temperature gradient, the presence of local areas with strong differences, and others. Security and control system are main areas of application. A noise on the images strongly influences the subsequent processing and decision making. This paper considers the problem of primary signal processing for solving the tasks of image denoising and deblurring of multispectral data. The additional information from multispectral channels can improve the efficiency of object classification. In this paper we use method of combining information about the objects obtained by the cameras in different frequency bands. We apply method based on simultaneous minimization L2 and the first order square difference sequence of estimates to denoising and restoring the blur on the edges. In case of loss of the information will be applied an approach based on the interpolation of data taken from the analysis of objects located in other areas and information obtained from multispectral camera. The effectiveness of the proposed approach is shown in a set of test images.
Han, Seokmin; Kang, Dong-Goo
2014-01-01
An easily implementable tissue cancellation method for dual energy mammography is proposed to reduce anatomical noise and enhance lesion visibility. For dual energy calibration, the images of an imaging object are directly mapped onto the images of a customized calibration phantom. Each pixel pair of the low and high energy images of the imaging object was compared to pixel pairs of the low and high energy images of the calibration phantom. The correspondence was measured by absolute difference between the pixel values of imaged object and those of the calibration phantom. Then the closest pixel pair of the calibration phantom images is marked and selected. After the calibration using direct mapping, the regions with lesion yielded different thickness from the background tissues. Taking advantage of the different thickness, the visibility of cancerous lesions was enhanced with increased contrast-to-noise ratio, depending on the size of lesion and breast thickness. However, some tissues near the edge of imaged object still remained after tissue cancellation. These remaining residuals seem to occur due to the heel effect, scattering, nonparallel X-ray beam geometry and Poisson distribution of photons. To improve its performance further, scattering and the heel effect should be compensated.
NASA Astrophysics Data System (ADS)
Ansory, Achmad; Prajitno, Prawito; Wijaya, Sastra Kusuma
2018-02-01
Electrical Impedance Tomography (EIT) is an imaging method that is able to estimate electrical impedance distribution inside an object. This EIT system is developed by using 32 electrodes and microcontroller based module. From a pair of electrodes, sinusoidal current of 3 mA is injected and the voltage differences between other pairs of electrodes are measured. Voltage measurement data are then sent to MATLAB and EIDORS software; the data are used to reconstruct two dimensions image. The system can detect and determine the position of a phantom in the tank. The object's position is accurately reconstructed and determined with the average shifting of 0.69 cm but object's area cannot be accurately reconstructed. The object's image is more accurately reconstructed when the object is located near to electrodes, has a larger size, and when the current injected to the system has a frequency of 100 kHz or 200kHz.
Dexterous ultrasonic levitation of millimeter-sized objects in air.
Seah, Sue Ann; Drinkwater, Bruce W; Carter, Tom; Malkin, Rob; Subramanian, Sriram
2014-07-01
Acoustic levitation in air has applications in contactless handling and processing. Here a first-order Bessel function-shaped acoustic field, generated using an 8-element circular array operating at 40 kHz, traps millimeter-sized objects against gravity. The device can manipulate objects in a vertical plane over a few millimeters with an accuracy of ± 0.09 mm.
[Estimates of the size of inhibitory areas in crowding effects in periphery].
Bondarko, V M; Danilova, M V; Solnushkin, S D; Chikhman, V N
2014-01-01
In psychophysical experiments we studied how surround influences recognition of test objects. The tests were low-contrast Landolt rings of the size 1.1, 1.5 and 2.3 deg. Their centers were located at 13.2 deg from the fixation point. The additional objects were similar Landolt rings or rings without gaps. The distance between the centers of the test and the additional objects varied from 2.2 to 13.2 deg. Inone experiment, the task of the observer was to identify both the test objects and the surrounding objects. In the second experiment the stimulus layout was the same, but'identification of only the test stimulus was required. In both experiments, deterioration of performance was found at all distances between the test objects and the surround, but the deterioration was more significant when the observer carried out the dual task. The data showed that the size of the inhibitory areas in our case does not comply with the Bouma low which states that the size of the interaction areas are equal to half of the eccentricity where the test is presented. Further deterioration of performance in the dual task reveals the contribution of attention into peripheral crowding effects.
NASA Astrophysics Data System (ADS)
Liu, Cenwei; Lobb, David; Li, Sheng; Owens, Philip; Kuzyk, ZouZou
2014-05-01
Lake Winnipeg has recently brought attention to the deteriorated water quality due to in part to nutrient and sediment input from agricultural land. Improving water quality in Lake Winnipeg requires the knowledge of the sediment sources within this ecosystem. There are a variety of environmental fingerprinting techniques have been successfully used in the assessment of sediment sources. In this study, we used particle size distribution to evaluate spatial and temporal variations of suspended sediment and potential sediment sources collected in the Tobacco Creek Watershed in Manitoba, Canada. The particle size distribution of suspended sediment can reflect the origin of sediment and processes during sediment transport, deposition and remobilization within the watershed. The objectives of this study were to quantify visually observed spatial and temporal changes in sediment particles, and to assess the sediment source using a rapid and cost-effective fingerprinting technique based on particle size distribution. The suspended sediment was collected by sediment traps twice a year during rainfall and snowmelt periods from 2009 to 2012. The potential sediment sources included the top soil of cultivated field, riparian area and entire profile from stream banks. Suspended sediment and soil samples were pre-wet with RO water and sieved through 600 μm sieve before analyzing. Particle size distribution of all samples was determined using a Malvern Mastersizer 2000S laser diffraction with the measurement range up to 600μm. Comparison of the results for different fractions of sediment showed significant difference in particle size distribution of suspended sediment between snowmelt and rainfall events. An important difference of particle size distribution also found between the cultivated soil and forest soil. This difference can be explained by different land uses which provided a distinct fingerprint of sediment. An overall improvement in water quality can be achieved by managing sediment according to the identified sediment sources in the watershed.
Relationship between pineal cyst size and aqueductal CSF flow measured by phase contrast MRI.
Bezuidenhout, Abraham F; Kasper, Ekkehard M; Baledent, Olivier; Rojas, Rafael; Bhadelia, Rafeeque A
2018-02-23
Most patients with pineal cysts referred for neurosurgical consultation have no specific symptoms or objective findings except for pineal cyst size to help in management decisions. Our purpose was to assess the relationship between pineal cyst size and aqueductal CSF flow using PC-MRI. Eleven adult patients with pineal cysts (> 1-cm in size) referred for neurosurgical consultations were included. Cyst volume was calculated using 3D T1 images. PC-MRI in axial plane with velocity encoding of 5 cm/sec was used to quantitatively assess CSF flow through the cerebral aqueduct to determine the aqueductal stroke volume, which was then correlated to cyst size using Pearson's correlation. Pineal cysts were grouped by size into small (6/11) and large (5/11) using the median value to compare aqueductal stroke volume using Mann-Whitney test. Patients were 39 ± 13 years (mean ± SD) of age, and 10/11 (91%) were female. There was significant negative correlation between cyst volume and aqueductal stroke volume (r=0.74; p=0.009). Volume of small cysts (4954±2157 mm3) was significantly different compared to large cysts (13752±3738 mm3; p= 0.008). The aqueductal stroke volume of patients harboring large cysts 33±8 μL/cardiac cycle was significantly lower than that of patients with small cysts 96±29 μL/cardiac cycle (p=0.008). Aqueductal CSF flow appears to decrease with increasing pineal cyst size. Our preliminary results provide first evidence that even in the absence of objective neurological findings or hydrocephalus; larger pineal cysts already display decreased CSF flow through the cerebral aqueduct.
Shape Distribution of Fragments from Microsatellite Impact Tests
NASA Technical Reports Server (NTRS)
Liou, J.C.; Hanada, T.
2009-01-01
Fragment shape is an important factor for conducting reliable orbital debris damage assessments for critical space assets, such as the International Space Station. To date, seven microsatellite impact tests have been completed as part of an ongoing collaboration between Kyushu University and the NASA Orbital Debris Program Office. The target satellites ranged in size from 15 cm 15 cm 15 cm to 20 cm 20 cm 20 cm. Each target satellite was equipped with fully functional electronics, including circuits, battery, and transmitter. Solar panels and multi-layer insulation (MLI) were added to the target satellites of the last two tests. The impact tests were carried out with projectiles of different sizes and impact speeds. All fragments down to about 2 mm in size were collected and analyzed based on their three orthogonal dimensions, x, y, and z, where x is the longest dimension, y is the longest dimension in the plane perpendicular to x, and z is the longest dimension perpendicular to both x and y. Each fragment was also photographed and classified by shape and material composition. This data set serves as the basis of our effort to develop a fragment shape distribution. Two distinct groups can be observed in the x/y versus y/z distribution of the fragments. Objects in the first group typically have large x/y values. Many of them are needle-like objects originating from the fragmentation of carbon fiber reinforced plastic materials used to construct the satellites. Objects in the second group tend to have small x/y values, and many of them are box-like or plate-like objects, depending on their y/z values. Each group forms the corresponding peak in the x/y distribution. However, only one peak can be observed in the y/z distribution. These distributions and how they vary with size, material type, and impact parameters will be described in detail within the paper.
The impact of death awareness on sizes of self-representational objects.
McCabe, Simon; Vail, Kenneth E; Arndt, Jamie
2018-01-01
People seem to have a tendency to increase the relative size of self-representational objects. Prior research suggests that motivational factors may fuel that tendency, so the present research built from terror management theory to examine whether existential motivations - engendered by concerns about death - may have similar implications for self-relevant size biases. Specifically, across two studies (total N = 288), we hypothesized that reminders of death would lead participants to inflate the size of self-representational objects. Both studies suggested that relative to reminders of pain, mortality salience led participants to construct larger clay sculptures of themselves (vs. others; Study 1) and a larger ostensible video game avatar for the self (vs. others; Study 2). © 2017 The British Psychological Society.
Modelling the effects of trade-offs between long and short-term objectives in fisheries management.
Mardle, Simon; Pascoe, Sean
2002-05-01
Fisheries management is typically a complex problem, from both an environmental and political perspective. The main source of conflict occurs between the need for stock conservation and the need for fishing community well-being, which is typically measured by employment and income levels. For most fisheries, overexploitation of the stock requires a reduction in the level of fishing activity. While this may lead to long-term benefits (both conservation and economic), it also leads to a short-term reduction in employment and regional incomes. In regions which are heavily dependent on fisheries, short-term consequences of conservation efforts may be considerable. The relatively high degree of scientific uncertainty with respect to the status of the stocks and the relatively short lengths of political terms of office, generally give rise to the short-run view taking the highest priority when defining policy objectives. In this paper, a multi-objective model of the North Sea is developed that incorporates both long-term and short-term objectives. Optimal fleet sizes are estimated taking into consideration different preferences between the defined short-term and long-term objectives. The subsequent results from the model give the short-term and long-term equilibrium status of the fishery incorporating the effects of the short-term objectives. As would be expected, an optimal fleet from a short-term perspective is considerably larger than an optimal fleet from a long-run perspective. Conversely, stock sizes and sustainable yields are considerably lower in the long-term if a short-term perspective is used in setting management policies. The model results highlight what is essentially a principal-agent problem, with the objectives of the policy makers not necessarily reflecting the objectives of society as a whole.
Computational time analysis of the numerical solution of 3D electrostatic Poisson's equation
NASA Astrophysics Data System (ADS)
Kamboh, Shakeel Ahmed; Labadin, Jane; Rigit, Andrew Ragai Henri; Ling, Tech Chaw; Amur, Khuda Bux; Chaudhary, Muhammad Tayyab
2015-05-01
3D Poisson's equation is solved numerically to simulate the electric potential in a prototype design of electrohydrodynamic (EHD) ion-drag micropump. Finite difference method (FDM) is employed to discretize the governing equation. The system of linear equations resulting from FDM is solved iteratively by using the sequential Jacobi (SJ) and sequential Gauss-Seidel (SGS) methods, simulation results are also compared to examine the difference between the results. The main objective was to analyze the computational time required by both the methods with respect to different grid sizes and parallelize the Jacobi method to reduce the computational time. In common, the SGS method is faster than the SJ method but the data parallelism of Jacobi method may produce good speedup over SGS method. In this study, the feasibility of using parallel Jacobi (PJ) method is attempted in relation to SGS method. MATLAB Parallel/Distributed computing environment is used and a parallel code for SJ method is implemented. It was found that for small grid size the SGS method remains dominant over SJ method and PJ method while for large grid size both the sequential methods may take nearly too much processing time to converge. Yet, the PJ method reduces computational time to some extent for large grid sizes.
Cao, Yongqiang; Grossberg, Stephen; Markowitz, Jeffrey
2011-12-01
All primates depend for their survival on being able to rapidly learn about and recognize objects. Objects may be visually detected at multiple positions, sizes, and viewpoints. How does the brain rapidly learn and recognize objects while scanning a scene with eye movements, without causing a combinatorial explosion in the number of cells that are needed? How does the brain avoid the problem of erroneously classifying parts of different objects together at the same or different positions in a visual scene? In monkeys and humans, a key area for such invariant object category learning and recognition is the inferotemporal cortex (IT). A neural model is proposed to explain how spatial and object attention coordinate the ability of IT to learn invariant category representations of objects that are seen at multiple positions, sizes, and viewpoints. The model clarifies how interactions within a hierarchy of processing stages in the visual brain accomplish this. These stages include the retina, lateral geniculate nucleus, and cortical areas V1, V2, V4, and IT in the brain's What cortical stream, as they interact with spatial attention processes within the parietal cortex of the Where cortical stream. The model builds upon the ARTSCAN model, which proposed how view-invariant object representations are generated. The positional ARTSCAN (pARTSCAN) model proposes how the following additional processes in the What cortical processing stream also enable position-invariant object representations to be learned: IT cells with persistent activity, and a combination of normalizing object category competition and a view-to-object learning law which together ensure that unambiguous views have a larger effect on object recognition than ambiguous views. The model explains how such invariant learning can be fooled when monkeys, or other primates, are presented with an object that is swapped with another object during eye movements to foveate the original object. The swapping procedure is predicted to prevent the reset of spatial attention, which would otherwise keep the representations of multiple objects from being combined by learning. Li and DiCarlo (2008) have presented neurophysiological data from monkeys showing how unsupervised natural experience in a target swapping experiment can rapidly alter object representations in IT. The model quantitatively simulates the swapping data by showing how the swapping procedure fools the spatial attention mechanism. More generally, the model provides a unifying framework, and testable predictions in both monkeys and humans, for understanding object learning data using neurophysiological methods in monkeys, and spatial attention, episodic learning, and memory retrieval data using functional imaging methods in humans. Copyright © 2011 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Nzioka, A. M.; Kim, Y. J.
2018-01-01
In this study, we present the results of an experimental study of the use of the X-ray photoelectron spectroscopy (XPS) and atomic force microscopy (AFM) to characterise the coatings of the recovered E - glass fibres. The recovered E - glass fibres were obtained using chemical recycling process coupled with ultrasound cavitation. The objective of this study was to analyse the impact of chemical recycling and the ultrasound cavitation process on the sizing properties of the recovered fibres. We obtained the recovered fibres and sized using 1 wt% 3 - aminopropyltriethoxysilane (APS). Part of the sized fibres was washed with acetone and analysed all the sample fibres using AFM and XPS. Results showed the different composition of sizing after extraction using acetone. We compared the results of this study with that of virgin clean glass fibres.
Brain size is correlated with endangerment status in mammals.
Abelson, Eric S
2016-02-24
Increases in relative encephalization (RE), brain size after controlling for body size, comes at a great metabolic cost and is correlated with a host of cognitive traits, from the ability to count objects to higher rates of innovation. Despite many studies examining the implications and trade-offs accompanying increased RE, the relationship between mammalian extinction risk and RE is unknown. I examine whether mammals with larger levels of RE are more or less likely to be at risk of endangerment than less-encephalized species. I find that extant species with large levels of encephalization are at greater risk of endangerment, with this effect being strongest in species with small body sizes. These results suggest that RE could be a valuable asset in estimating extinction vulnerability. Additionally, these findings suggest that the cost-benefit trade-off of RE is different in large-bodied species when compared with small-bodied species. © 2016 The Author(s).
The relationship between oral tori and bite force.
Jeong, Chan-Woo; Kim, Kyung-Ho; Jang, Hyo-Won; Kim, Hye-Sun; Huh, Jong-Ki
2018-01-12
Objective The relationship between bite force and torus palatinus or mandibularis remains to be explained. The major aim of this study was to determine the correlation between bite force and oral tori. Methods The bite force of 345 patients was measured with a bite force recorder; impressions of the shape and size of the oral tori were taken on plaster models prior to orthodontic treatments. Subsequently, the relationship between oral tori and bite force was analyzed. Results The size, shape, and incidence of torus palatinus was not significantly correlated with bite force. However, the size of torus mandibularis increased significantly in proportion to the bite force (p = 0.020). The occurrence of different types of oral tori was not correlated with the bite force. Discussion The size of torus mandibularis provides information about bite force and can thus be used to clinically assess occlusal stress.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cicek, T.
2008-07-01
This study dealt with the upgrading of two different type of Turkish coal by a dry cleaning method using a modified air table. The industrial size air table used in this study is a device for removing stones from agricultural products. This study investigates the technical and economical feasibility of the dry cleaning method which has never been applied before on coals in Turkey. The application of a dry cleaning method on Turkish coals designated for power generation without generating environmental pollution and ensuring a stable coal quality are the main objectives of this study. The size fractions of 5-8,more » 3-5, and 1-3 mm of the investigated coals were used in the upgrading experiments. Satisfactory results were achieved with coal from the Soma region, whereas the upgrading results of Hsamlar coal were objectionable for the coarser size fractions. However, acceptable results were obtained for the size fraction 1-3 mm of Hsamlar coal.« less
Elevational gradient in clutch size of Red-faced Warblers
Dillon, Kristen G.; Conway, Courtney J.
2015-01-01
Our understanding of life history evolution has benefited from debates regarding the underlying causes, and geographic ubiquity, of spatial patterns in avian clutch sizes. Past studies have revealed that birds lay smaller clutch sizes at higher elevation. However, in most previous studies, investigators have failed to adequately control for elevational differences in breeding phenology. To better understand the elevational gradient in avian clutch size, we need to know how clutch size changes across the entire elevational breeding range of a species (i.e., the shape of the relationship between elevation and clutch size), and whether the elevational gradient in clutch size is merely an artifact of elevational gradients in breeding phenology or breeding season length. We examined the relationship between breeding elevation and clutch size of Red-faced Warblers (Cardellina rubrifrons) along a 1000-m elevational gradient in Arizona. Our objectives were to determine how clutch size changed with elevation, and if the relationship between clutch size and elevation merely reflected elevational changes in breeding season length or phenology. The proportion of 5-egg clutches decreased and the proportion of 3- and 4-egg clutches increased non-linearly with increasing elevation, even after controlling for the elevational gradient in nest initiation date. Thus, average clutch size declined across the elevational breeding range of Red-faced Warblers, but this decline was not due to elevational variation in breeding phenology. Timing of breeding changed, but the duration of the breeding season did not change appreciably across the elevational gradient. Hence, elevational differences in breeding season length or breeding phenology cannot explain why Red-faced Warblers (and perhaps other birds) breeding at higher elevations have smaller clutches.
Fuzzy hidden Markov chains segmentation for volume determination and quantitation in PET.
Hatt, M; Lamare, F; Boussion, N; Turzo, A; Collet, C; Salzenstein, F; Roux, C; Jarritt, P; Carson, K; Cheze-Le Rest, C; Visvikis, D
2007-06-21
Accurate volume of interest (VOI) estimation in PET is crucial in different oncology applications such as response to therapy evaluation and radiotherapy treatment planning. The objective of our study was to evaluate the performance of the proposed algorithm for automatic lesion volume delineation; namely the fuzzy hidden Markov chains (FHMC), with that of current state of the art in clinical practice threshold based techniques. As the classical hidden Markov chain (HMC) algorithm, FHMC takes into account noise, voxel intensity and spatial correlation, in order to classify a voxel as background or functional VOI. However the novelty of the fuzzy model consists of the inclusion of an estimation of imprecision, which should subsequently lead to a better modelling of the 'fuzzy' nature of the object of interest boundaries in emission tomography data. The performance of the algorithms has been assessed on both simulated and acquired datasets of the IEC phantom, covering a large range of spherical lesion sizes (from 10 to 37 mm), contrast ratios (4:1 and 8:1) and image noise levels. Both lesion activity recovery and VOI determination tasks were assessed in reconstructed images using two different voxel sizes (8 mm3 and 64 mm3). In order to account for both the functional volume location and its size, the concept of % classification errors was introduced in the evaluation of volume segmentation using the simulated datasets. Results reveal that FHMC performs substantially better than the threshold based methodology for functional volume determination or activity concentration recovery considering a contrast ratio of 4:1 and lesion sizes of <28 mm. Furthermore differences between classification and volume estimation errors evaluated were smaller for the segmented volumes provided by the FHMC algorithm. Finally, the performance of the automatic algorithms was less susceptible to image noise levels in comparison to the threshold based techniques. The analysis of both simulated and acquired datasets led to similar results and conclusions as far as the performance of segmentation algorithms under evaluation is concerned.
Fazey, Francesca M C; Ryan, Peter G
2016-03-01
Recent estimates suggest that roughly 100 times more plastic litter enters the sea than is found floating at the sea surface, despite the buoyancy and durability of many plastic polymers. Biofouling by marine biota is one possible mechanism responsible for this discrepancy. Microplastics (<5 mm in diameter) are more scarce than larger size classes, which makes sense because fouling is a function of surface area whereas buoyancy is a function of volume; the smaller an object, the greater its relative surface area. We tested whether plastic items with high surface area to volume ratios sank more rapidly by submerging 15 different sizes of polyethylene samples in False Bay, South Africa, for 12 weeks to determine the time required for samples to sink. All samples became sufficiently fouled to sink within the study period, but small samples lost buoyancy much faster than larger ones. There was a direct relationship between sample volume (buoyancy) and the time to attain a 50% probability of sinking, which ranged from 17 to 66 days of exposure. Our results provide the first estimates of the longevity of different sizes of plastic debris at the ocean surface. Further research is required to determine how fouling rates differ on free floating debris in different regions and in different types of marine environments. Such estimates could be used to improve model predictions of the distribution and abundance of floating plastic debris globally. Copyright © 2016 Elsevier Ltd. All rights reserved.
Cundall, Amelia; Guo, Kun
2017-01-01
Often with minimally clothed figures depicting extreme body sizes, previous studies have shown women tend to gaze at evolutionary determinants of attractiveness when viewing female bodies, possibly for self-evaluation purposes, and their gaze distribution is modulated by own body dissatisfaction level. To explore to what extent women's body-viewing gaze behaviour is affected by clothing type, dress size, subjective measurements of regional body satisfaction and objective measurements of own body composition (e.g., chest size, body mass index, waist-to-hip ratio), in this self-paced body attractiveness and body size judgement experiment, we compared healthy, young women's gaze distributions when viewing female bodies in tight and loose clothing of different dress sizes. In contrast to tight clothing, loose clothing biased gaze away from the waist-hip to the leg region, and subsequently led to enhanced body attractiveness ratings and body size underestimation for larger female bodies, indicating the important role of clothing in mediating women's body perception. When viewing preferred female bodies, women's higher satisfaction of a specific body region was associated with an increased gaze towards neighbouring body areas, implying satisfaction might reduce the need for comparison of confident body parts; furthermore undesirable body composition measurements were correlated with a gaze avoidance process if the construct was less changeable (i.e. chest size) but a gaze comparison process if the region was more changeable (i.e. body mass index, dress size). Clearly, own body satisfaction and body composition measurements had an evident impact on women's body-viewing gaze allocation, possibly through different cognitive processes.
Temperature-dependent and optimized thermal emission by spheres
NASA Astrophysics Data System (ADS)
Nguyen, K. L.; Merchiers, O.; Chapuis, P.-O.
2018-03-01
We investigate the temperature and size dependencies of thermal emission by homogeneous spheres as a function of their dielectric properties. Different power laws obtained in this work show that the emitted power can depart strongly from the usual fourth power of temperature given by Planck's law and from the square or the cube of the radius. We also show how to optimize the thermal emission by selecting permittivities leading to resonances, which allow for the so-called super-Planckian regime. These results will be useful as spheres, i.e. the simplest finite objects, are often considered as building blocks of more complex objects.
NASA Technical Reports Server (NTRS)
Mashiku, Alinda K.; Carpenter, J. Russell
2016-01-01
The cadence of proximity operations for the OSIRIS-REx mission may have an extra induced challenge given the potential of the detection of a natural satellite orbiting the asteroid Bennu. Current ground radar observations for object detection orbiting Bennu show no found objects within bounds of specific size and rotation rates. If a natural satellite is detected during approach, a different proximity operation cadence will need to be implemented as well as a collision avoidance strategy for mission success. A collision avoidance strategy will be analyzed using the Wald Sequential Probability Ratio Test.
NASA Technical Reports Server (NTRS)
Mashiku, Alinda; Carpenter, Russell
2016-01-01
The cadence of proximity operations for the OSIRIS-REx mission may have an extra induced challenge given the potential of the detection of a natural satellite orbiting the asteroid Bennu. Current ground radar observations for object detection orbiting Bennu show no found objects within bounds of specific size and rotation rates. If a natural satellite is detected during approach, a different proximity operation cadence will need to be implemented as well as a collision avoidance strategy for mission success. A collision avoidance strategy will be analyzed using the Wald Sequential Probability Ratio Test.
Looking at the world with your ears: how do we get the size of an object from its sound?
Grassi, Massimo; Pastore, Massimiliano; Lemaitre, Guillaume
2013-05-01
Identifying the properties of on-going events by the sound they produce is crucial for our interaction with the environment when visual information is not available. Here, we investigated the ability of listeners to estimate the size of an object (a ball) dropped on a plate with ecological listening conditions (balls were dropped in real time) and response methods (listeners estimate ball-size by drawing a disk). Previous studies had shown that listeners can veridically estimate the size of objects by the sound they produce, but it is yet unclear which acoustical index listeners use to produce their estimates. In particular, it is unclear whether listeners listen to amplitude (related to loudness) or frequency (related to the sound's brightness) domain cue to produce their estimates. In the current study, in order to understand which cue is used by the listener to recover the size of the object, we manipulated the sound source event in such a way that frequency and amplitude cues provided contrasting size-information (balls were dropped from various heights). Results showed that listeners' estimations were accurate regardless of the experimental manipulations performed in the experiments. In addition, results suggest that listeners were likely integrating frequency and amplitude acoustical cues in order to produce their estimate and although these cues were often providing contrasting size-information. Copyright © 2013 Elsevier B.V. All rights reserved.
A review of supervised object-based land-cover image classification
NASA Astrophysics Data System (ADS)
Ma, Lei; Li, Manchun; Ma, Xiaoxue; Cheng, Liang; Du, Peijun; Liu, Yongxue
2017-08-01
Object-based image classification for land-cover mapping purposes using remote-sensing imagery has attracted significant attention in recent years. Numerous studies conducted over the past decade have investigated a broad array of sensors, feature selection, classifiers, and other factors of interest. However, these research results have not yet been synthesized to provide coherent guidance on the effect of different supervised object-based land-cover classification processes. In this study, we first construct a database with 28 fields using qualitative and quantitative information extracted from 254 experimental cases described in 173 scientific papers. Second, the results of the meta-analysis are reported, including general characteristics of the studies (e.g., the geographic range of relevant institutes, preferred journals) and the relationships between factors of interest (e.g., spatial resolution and study area or optimal segmentation scale, accuracy and number of targeted classes), especially with respect to the classification accuracy of different sensors, segmentation scale, training set size, supervised classifiers, and land-cover types. Third, useful data on supervised object-based image classification are determined from the meta-analysis. For example, we find that supervised object-based classification is currently experiencing rapid advances, while development of the fuzzy technique is limited in the object-based framework. Furthermore, spatial resolution correlates with the optimal segmentation scale and study area, and Random Forest (RF) shows the best performance in object-based classification. The area-based accuracy assessment method can obtain stable classification performance, and indicates a strong correlation between accuracy and training set size, while the accuracy of the point-based method is likely to be unstable due to mixed objects. In addition, the overall accuracy benefits from higher spatial resolution images (e.g., unmanned aerial vehicle) or agricultural sites where it also correlates with the number of targeted classes. More than 95.6% of studies involve an area less than 300 ha, and the spatial resolution of images is predominantly between 0 and 2 m. Furthermore, we identify some methods that may advance supervised object-based image classification. For example, deep learning and type-2 fuzzy techniques may further improve classification accuracy. Lastly, scientists are strongly encouraged to report results of uncertainty studies to further explore the effects of varied factors on supervised object-based image classification.
Clay, Olivio J; Wadley, Virginia G; Edwards, Jerri D; Roth, David L; Roenker, Daniel L; Ball, Karlene K
2005-08-01
Driving is a complex behavior that requires the utilization of a wide range of individual abilities. Identifying assessments that not only capture individual differences, but also are related to older adults' driving performance would be beneficial. This investigation examines the relationship between the Useful Field of View (UFOV) assessment and objective measures of retrospective or concurrent driving performance, including state-recorded accidents, on-road driving, and driving simulator performance. The PubMed and PsycINFO databases were searched to retrieve eight studies that reported bivariate relationships between UFOV and these objective driving measures. Cumulative meta-analysis techniques were used to combine the effect sizes in an attempt to determine whether the strength of the relationship was stable across studies and to assess whether a sufficient number of studies have been conducted to validate the relationship between UFOV and driving performance. A within-group homogeneity of effect sizes test revealed that the samples could be thought of as being drawn from the same population, Q [7] = 11.29, p (one-tailed) = 0.13. Therefore, the effect sizes of eight studies were combined for the present cumulative meta-analysis. The weighted mean effect size across the studies revealed a large effect (Cohen's d = 0.945), with poorer UFOV performance associated with negative driving outcomes. This relationship was robust across multiple indices of driving performance and several research laboratories. This convergence of evidence across numerous studies using different methodologies confirms the importance of the UFOV assessment as a valid and reliable index of driving performance and safety. Recent prospective studies have confirmed a relationship between UFOV performance and future crashes, further supporting the use of this instrument as a potential screening measure for at-risk older drivers.
Position Information Encoded by Population Activity in Hierarchical Visual Areas
Majima, Kei; Horikawa, Tomoyasu
2017-01-01
Abstract Neurons in high-level visual areas respond to more complex visual features with broader receptive fields (RFs) compared to those in low-level visual areas. Thus, high-level visual areas are generally considered to carry less information regarding the position of seen objects in the visual field. However, larger RFs may not imply loss of position information at the population level. Here, we evaluated how accurately the position of a seen object could be predicted (decoded) from activity patterns in each of six representative visual areas with different RF sizes [V1–V4, lateral occipital complex (LOC), and fusiform face area (FFA)]. We collected functional magnetic resonance imaging (fMRI) responses while human subjects viewed a ball randomly moving in a two-dimensional field. To estimate population RF sizes of individual fMRI voxels, RF models were fitted for individual voxels in each brain area. The voxels in higher visual areas showed larger estimated RFs than those in lower visual areas. Then, the ball’s position in a separate session was predicted by maximum likelihood estimation using the RF models of individual voxels. We also tested a model-free multivoxel regression (support vector regression, SVR) to predict the position. We found that regardless of the difference in RF size, all visual areas showed similar prediction accuracies, especially on the horizontal dimension. Higher areas showed slightly lower accuracies on the vertical dimension, which appears to be attributed to the narrower spatial distributions of the RF centers. The results suggest that much position information is preserved in population activity through the hierarchical visual pathway regardless of RF sizes and is potentially available in later processing for recognition and behavior. PMID:28451634
Velu, Juliëtte F; Groot Jebbink, Erik; de Vries, Jean-Paul Pm; van der Palen, Job Am; Slump, Cornelis H; Geelkerken, Robert H
2018-04-01
Objectives Correct sizing of endoprostheses used for the treatment of abdominal aortic aneurysms is important to prevent endoleaks and migration. Sizing requires several steps and each step introduces a possible sizing error. The goal of this study was to investigate the magnitude of these errors compared to the golden standard: a vessel phantom. This study focuses on the errors in sizing with three different brands of computed tomography angiography scanners in combination with three reconstruction software packages. Methods Three phantoms with a different diameter, altitude and azimuth were scanned with three computed tomography scanners: Toshiba Aquilion 64-slice, Philips Brilliance iCT 256-slice and Siemens Somatom Sensation 64-slice. The phantom diameters were determined in the stretched view after central lumen line reconstruction by three observers using Simbionix PROcedure Rehearsal Studio, 3mensio and TeraRecon planning software. The observers, all novices in sizing endoprostheses using planning software, measured 108 slices each. Two senior vascular surgeons set the tolerated error margin of sizing on ±1.0 mm. Results In total, 11.3% of the measurements (73/648) were outside the set margins of ±1.0 mm from the phantom diameter, with significant differences between the scanner types (14.8%, 12.1%, 6.9% for the Siemens scanner, Philips scanner and Toshiba scanner, respectively, p-value = 0.032), but not between the software packages (8.3%, 11.1%, 14.4%, p-value = 0.141) or the observers (10.6%, 9.7%, 13.4%, p-value = 0.448). Conclusions It can be concluded that the errors in sizing were independent of the used software packages, but the phantoms scanned with Siemens scanner were significantly more measured incorrectly than the phantoms scanned with the Toshiba scanner. Consequently, awareness on the type of computed tomography scanner and computed tomography scanner setting is necessary, especially in complex abdominal aortic aneurysms sizing for fenestrated or branched endovascular aneurysm repair if appropriate the sizing is of upmost importance.
Discovery Bottles: A Unique Inexpensive Tool for the K-2 Science Classroom
ERIC Educational Resources Information Center
Watson, Sandy
2008-01-01
Discover discovery bottles! These wide-mouth plastic containers of any size filled with objects of different kinds can be terrific tools for science explorations and a great way to cultivate science minds in a K-2 science classroom. In addition, the author has found them to be a useful, inexpensive, and engaging way to help students develop skills…
Properties of Matter. Physical Science in Action[TM]. Schlessinger Science Library. [Videotape].
ERIC Educational Resources Information Center
2000
Everything in the universe consists of matter. So how can the differences between various types of matter be distinguished? Besides color, shape and size, there are more detailed properties that are used to define matter. Mass, weight, volume and density are all related to tell a great deal about an object or substance. Students will learn about…
W.G. Maxwell; F.R. Ward
1979-01-01
Five series of photographs display different forest residue loading levels, by size classes, for areas of like timber type (Sierra mixed conifer and Sierra true fir) and cutting objective. Information with each photo includes measured weights, volumes and other residue data, information about the timber stand and harvest actions, and assessment of fire behavior and...
Reproductive characteristics of a coyote population before and during exploitation
John C. Kilgo; Christopher E. Shaw; Mark Vukovich; Michael J. Conroy; Charles Ruth
2017-01-01
The eastward expansion of coyotes (Canis latrans) has brought the species into ecosystems and landscapes different from those it historically occupied, yet little is known about the reproductive biology of coyotes in the southeastern United States or the effects of exploitation on reproduction in coyotes. Our objective was to quantify litter size,...
ERIC Educational Resources Information Center
Beste, Christian; Heil, Martin; Konrad, Carsten
2010-01-01
The cognitive process of imaging an object turning around is called mental rotation. Many studies have been put forward analyzing mental rotation by means of event-related potentials (ERPs). Event-related potentials (ERPs) were measured during mental rotation of characters in a sample (N = 82) with a sufficient size to obtain even small effects. A…
USDA-ARS?s Scientific Manuscript database
Our objective was to determine if differences exist in hormone sensitive organ size between infants fed soy formula (SF), milk formula (MF), or breast milk (BF). Breast buds, uterus, ovaries, prostate, and testicular volumes were assessed by ultrasonography in 40 BF, 41 MF, and 39 SF infants at age ...
NASA Technical Reports Server (NTRS)
Simpson, R. W.
1972-01-01
The design parameters which determine cruise performance for a conventional subsonic jet transport are discussed. It is assumed that the aircraft burns climb fuel to reach cruising altitude and that aeronautical technology determines the ability to carry a given payload at cruising altitude. It is shown that different sizes of transport aircraft are needed to provide the cost optimal vehicle for different given payload-range objectives.
Economies of scale: The physics basis
NASA Astrophysics Data System (ADS)
Bejan, A.; Almerbati, A.; Lorente, S.
2017-01-01
Why is size so important? Why are "economies of scale" a universal feature of all flow systems, animate, inanimate, and human made? The empirical evidence is clear: the bigger are more efficient carriers (per unit) than the smaller. This natural tendency is observed across the board, from animal design to technology, logistics, and economics. In this paper, we rely on physics (thermodynamics) to determine the relation between the efficiency and size. Here, the objective is to predict a natural phenomenon, which is universal. It is not to model a particular type of device. The objective is to demonstrate based on physics that the efficiencies of diverse power plants should increase with size. The analysis is performed in two ways. First is the tradeoff between the "external" irreversibilities due to the temperature differences that exist above and below the temperature range occupied by the circuit executed by the working fluid. Second is the allocation of the fluid flow irreversibility between the hot and cold portions of the fluid flow circuit. The implications of this report in economics and design science (scaling up, scaling down) and the necessity of multi-scale design with hierarchy are discussed.
Maximizing Information Diffusion in the Cyber-physical Integrated Network †
Lu, Hongliang; Lv, Shaohe; Jiao, Xianlong; Wang, Xiaodong; Liu, Juan
2015-01-01
Nowadays, our living environment has been embedded with smart objects, such as smart sensors, smart watches and smart phones. They make cyberspace and physical space integrated by their abundant abilities of sensing, communication and computation, forming a cyber-physical integrated network. In order to maximize information diffusion in such a network, a group of objects are selected as the forwarding points. To optimize the selection, a minimum connected dominating set (CDS) strategy is adopted. However, existing approaches focus on minimizing the size of the CDS, neglecting an important factor: the weight of links. In this paper, we propose a distributed maximizing the probability of information diffusion (DMPID) algorithm in the cyber-physical integrated network. Unlike previous approaches that only consider the size of CDS selection, DMPID also considers the information spread probability that depends on the weight of links. To weaken the effects of excessively-weighted links, we also present an optimization strategy that can properly balance the two factors. The results of extensive simulation show that DMPID can nearly double the information diffusion probability, while keeping a reasonable size of selection with low overhead in different distributed networks. PMID:26569254
Modeling of LEO Orbital Debris Populations in Centimeter and Millimeter Size Regimes
NASA Technical Reports Server (NTRS)
Xu, Y.-L.; Hill, . M.; Horstman, M.; Krisko, P. H.; Liou, J.-C.; Matney, M.; Stansbery, E. G.
2010-01-01
The building of the NASA Orbital Debris Engineering Model, whether ORDEM2000 or its recently updated version ORDEM2010, uses as its foundation a number of model debris populations, each truncated at a minimum object-size ranging from 10 micron to 1 m. This paper discusses the development of the ORDEM2010 model debris populations in LEO (low Earth orbit), focusing on centimeter (smaller than 10 cm) and millimeter size regimes. Primary data sets used in the statistical derivation of the cm- and mm-size model populations are from the Haystack radar operated in a staring mode. Unlike cataloged objects of sizes greater than approximately 10 cm, ground-based radars monitor smaller-size debris only in a statistical manner instead of tracking every piece. The mono-static Haystack radar can detect debris as small as approximately 5 mm at moderate LEO altitudes. Estimation of millimeter debris populations (for objects smaller than approximately 6 mm) rests largely on Goldstone radar measurements. The bi-static Goldstone radar can detect 2- to 3-mm objects. The modeling of the cm- and mm-debris populations follows the general approach to developing other ORDEM2010-required model populations for various components and types of debris. It relies on appropriate reference populations to provide necessary prior information on the orbital structures and other important characteristics of the debris objects. NASA's LEO-to-GEO Environment Debris (LEGEND) model is capable of furnishing such reference populations in the desired size range. A Bayesian statistical inference process, commonly adopted in ORDEM2010 model-population derivations, changes a priori distribution into a posteriori distribution and thus refines the reference populations in terms of data. This paper describes key elements and major steps in the statistical derivations of the cm- and mm-size debris populations and presents results. Due to lack of data for near 1-mm sizes, the model populations of 1- to 3.16-mm objects are an empirical extension from larger debris. The extension takes into account the results of micro-debris (from 10 micron to 1 mm) population modeling that is based on shuttle impact data, in the hope of making a smooth transition between micron and millimeter size regimes. This paper also includes a brief discussion on issues and potential future work concerning the analysis and interpretation of Goldstone radar data.
On marginally resolved objects in optical interferometry
NASA Astrophysics Data System (ADS)
Lachaume, R.
2003-03-01
With the present and soon-to-be breakthrough of optical interferometry, countless objects shall be within reach of interferometers; yet, most of them are expected to remain only marginally resolved with hectometric baselines. In this paper, we tackle the problem of deriving the properties of a marginally resolved object from its optical visibilities. We show that they depend on the moments of flux distribution of the object: centre, mean angular size, asymmetry, and curtosis. We also point out that the visibility amplitude is a second-order phenomenon, whereas the phase is a combination of a first-order term, giving the location of the photocentre, and a third-order term, more difficult to detect than the visibility amplitude, giving an asymmetry coefficient of the object. We then demonstrate that optical visibilities are not a good model constraint while the object stays marginally resolved, unless observations are carried out at different wavelengths. Finally, we show an application of this formalism to circumstellar discs.
Adipose tissue in muscle: a novel depot similar in size to visceral adipose tissue1-3
Gallagher, Dympna; Kuznia, Patrick; Heshka, Stanley; Albu, Jeanine; Heymsfield, Steven B; Goodpaster, Bret; Visser, Marjolein; Harris, Tamara B
2006-01-01
Background The manner in which fat depot volumes and distributions, particularly the adipose tissue (AT) between the muscles, vary by race is unknown. Objective The objective was to quantify a previously unstudied and novel intermuscular AT (IMAT) depot and subcutaneous AT, visceral AT (VAT), and total-body skeletal muscle mass in healthy sedentary African American (AA), Asian, and white adults by whole-body magnetic resonance imaging. IMAT is the AT between muscles and within the boundary of the muscle fascia. Design Analyses were conducted on 227 women [AA (n = 79): body mass index (BMI; in kg/m2), 29.0 ± 5.5; age, 45.7 ± 16.9 y; Asian (n = 38): BMI, 21.7 ± 2.9; age, 47.2 ± 19.9 y; whites (n = 110): BMI, 24.9 ± 5.4; age, 43.7 ± 16.2 y]) and 111 men [AA (n = 39): BMI, 25.6 ± 3.2; age, 45.5 ± 18.8 y; Asian (n = 13): BMI, 24.9 ± 2.5; age, 45.6 ± 25.0 y; white (n = 59): BMI, 25.8 ± 3.8; age 44.5 ± 16.3 y]. Results IMAT depots were not significantly different in size between race groups at low levels of adiposity; however, with increasing adiposity, AAs had a significantly greater increment in the proportion of total AT (TAT) than did the whites and Asians (58, 46, and 44 g IMAT/kg TAT, respectively; P = 0.001). VAT depots were not significantly different in size at low levels of adiposity but, with increasing adiposity, VAT accumulation was greater than IMAT accumulation in the Asians and whites; no significant differences were observed in AAs. Conclusion Race differences in AT distribution extend to IMAT, a depot that may influence race-ethnicity differences in dysglycemia. PMID:15817870
The Population of Optically Faint GEO Debris
NASA Technical Reports Server (NTRS)
Seitzer, Patrick; Barker, Ed; Buckalew, Brent; Burkhardt, Andrew; Cowardin, Heather; Frith, James; Gomez, Juan; Kaleida, Catherine; Lederer, Susan M.; Lee, Chris H.
2016-01-01
The 6.5-m Magellan telescope 'Walter Baade' at the Las Campanas Observatory in Chile has been used for spot surveys of the GEO orbital regime to study the population of optically faint GEO debris. The goal is to estimate the size of the population of GEO debris at sizes much smaller than can be studied with 1-meter class telescopes. Despite the small size of the field of view of the Magellan instrument (diameter 0.5-degree), a significant population of objects fainter than R = 19th magnitude have been found with angular rates consistent with circular orbits at GEO. We compare the size of this population with the numbers of GEO objects found at brighter magnitudes by smaller telescopes. The observed detections have a wide range in characteristics starting with those appearing as short uniform streaks. But there are a substantial number of detections with variations in brightness, flashers, during the 5-second exposure. The duration of each of these flashes can be extremely brief: sometimes less than half a second. This is characteristic of a rapidly tumbling object with a quite variable projected size times albedo. If the albedo is of the order of 0.2, then the largest projected size of these objects is around 10-cm. The data in this paper was collected over the last several years using Magellan's IMACS camera in f/2 mode. The analysis shows the brightness bins for the observed GEO population as well as the periodicity of the flashers. All objects presented are correlated with the catalog: the focus of the paper will be on the uncorrelated, optically faint, objects. The goal of this project is to better characterize the faint debris population in GEO that access to a 6.5-m optical telescope in a superb site can provide.
Multigrid contact detection method
NASA Astrophysics Data System (ADS)
He, Kejing; Dong, Shoubin; Zhou, Zhaoyao
2007-03-01
Contact detection is a general problem of many physical simulations. This work presents a O(N) multigrid method for general contact detection problems (MGCD). The multigrid idea is integrated with contact detection problems. Both the time complexity and memory consumption of the MGCD are O(N) . Unlike other methods, whose efficiencies are influenced strongly by the object size distribution, the performance of MGCD is insensitive to the object size distribution. We compare the MGCD with the no binary search (NBS) method and the multilevel boxing method in three dimensions for both time complexity and memory consumption. For objects with similar size, the MGCD is as good as the NBS method, both of which outperform the multilevel boxing method regarding memory consumption. For objects with diverse size, the MGCD outperform both the NBS method and the multilevel boxing method. We use the MGCD to solve the contact detection problem for a granular simulation system based on the discrete element method. From this granular simulation, we get the density property of monosize packing and binary packing with size ratio equal to 10. The packing density for monosize particles is 0.636. For binary packing with size ratio equal to 10, when the number of small particles is 300 times as the number of big particles, the maximal packing density 0.824 is achieved.
A Novel Event-Based Incipient Slip Detection Using Dynamic Active-Pixel Vision Sensor (DAVIS)
Rigi, Amin
2018-01-01
In this paper, a novel approach to detect incipient slip based on the contact area between a transparent silicone medium and different objects using a neuromorphic event-based vision sensor (DAVIS) is proposed. Event-based algorithms are developed to detect incipient slip, slip, stress distribution and object vibration. Thirty-seven experiments were performed on five objects with different sizes, shapes, materials and weights to compare precision and response time of the proposed approach. The proposed approach is validated by using a high speed constitutional camera (1000 FPS). The results indicate that the sensor can detect incipient slippage with an average of 44.1 ms latency in unstructured environment for various objects. It is worth mentioning that the experiments were conducted in an uncontrolled experimental environment, therefore adding high noise levels that affected results significantly. However, eleven of the experiments had a detection latency below 10 ms which shows the capability of this method. The results are very promising and show a high potential of the sensor being used for manipulation applications especially in dynamic environments. PMID:29364190
Minciardi, Riccardo; Paolucci, Massimo; Robba, Michela; Sacile, Roberto
2008-11-01
An approach to sustainable municipal solid waste (MSW) management is presented, with the aim of supporting the decision on the optimal flows of solid waste sent to landfill, recycling and different types of treatment plants, whose sizes are also decision variables. This problem is modeled with a non-linear, multi-objective formulation. Specifically, four objectives to be minimized have been taken into account, which are related to economic costs, unrecycled waste, sanitary landfill disposal and environmental impact (incinerator emissions). An interactive reference point procedure has been developed to support decision making; these methods are considered appropriate for multi-objective decision problems in environmental applications. In addition, interactive methods are generally preferred by decision makers as they can be directly involved in the various steps of the decision process. Some results deriving from the application of the proposed procedure are presented. The application of the procedure is exemplified by considering the interaction with two different decision makers who are assumed to be in charge of planning the MSW system in the municipality of Genova (Italy).
Thermal barriers constrain microbial elevational range size via climate variability.
Wang, Jianjun; Soininen, Janne
2017-08-01
Range size is invariably limited and understanding range size variation is an important objective in ecology. However, microbial range size across geographical gradients remains understudied, especially on mountainsides. Here, the patterns of range size of stream microbes (i.e., bacteria and diatoms) and macroorganisms (i.e., macroinvertebrates) along elevational gradients in Asia and Europe were examined. In bacteria, elevational range size showed non-significant phylogenetic signals. In all taxa, there was a positive relationship between niche breadth and species elevational range size, driven by local environmental and climatic variables. No taxa followed the elevational Rapoport's rule. Climate variability explained the most variation in microbial mean elevational range size, whereas local environmental variables were more important for macroinvertebrates. Seasonal and annual climate variation showed negative effects, while daily climate variation had positive effects on community mean elevational range size for all taxa. The negative correlation between range size and species richness suggests that understanding the drivers of range is key for revealing the processes underlying diversity. The results advance the understanding of microbial species thermal barriers by revealing the importance of seasonal and diurnal climate variation, and highlight that aquatic and terrestrial biota may differ in their response to short- and long-term climate variability. © 2017 Society for Applied Microbiology and John Wiley & Sons Ltd.
R-band host galaxy contamination of TeV γ-ray blazar Mrk 501: effects of aperture size and seeing
NASA Astrophysics Data System (ADS)
Feng, Hai-Cheng; Liu, Hong-Tao; Zhao, Ying-He; Bai, Jin-Ming; Wang, Fang; Fan, Xu-Liang
2018-02-01
We simulated the R-band contribution of the host galaxy of TeV γ-ray BL Lac object Mrk 501 in different aperture sizes and seeing conditions. An intensive set of observations was acquired with the 1.02 m optical telescope, managed by Yunnan Observatories, from 2010 May 15 to 18. Based on the host subtraction data usually used in the literature, the subtraction of host galaxy contamination results in significant seeing-brightness correlations. These correlations would lead to illusive large amplitude variations at short timescales, which will mask the intrinsic microvariability, thus giving rise to difficulty in detecting the intrinsic microvariability. Both aperture size and seeing condition influence the flux measurements, but the aperture size impacts the result more significantly. Based on the parameters of an elliptical galaxy provided in the literature, we simulated the host contributions of Mrk 501 in different aperture sizes and seeing conditions. Our simulation data of the host galaxy obviously weaken these significant seeing-brightness correlations for the host-subtracted brightness of Mrk 501, and can help us discover the intrinsic short timescale microvariability. The pure nuclear flux is ∼8.0mJy in the R band, i.e., the AGN has a magnitude of R ∼ 13.96 mag.
How much should I eat? Estimation of meal portions in anorexia nervosa.
Milos, Gabriella; Kuenzli, Cornelia; Soelch, Chantal Martin; Schumacher, Sonja; Moergeli, Hanspeter; Mueller-Pfeiffer, Christoph
2013-04-01
Pathological concern regarding one's weight and weight gain is a crucial feature of anorexia nervosa. Consequently, anorexia nervosa patients often claim that they are uncertain regarding the amount of food they should eat. The present study investigated whether individuals with anorexia nervosa show an altered estimation of meal portion sizes and whether this estimation is modulated by an intent-to-eat instruction (where patients are asked to imagine having to eat the presented meal), meal type and meal portion size. Twenty-four women with anorexia nervosa and 27 healthy women estimated, using a visual analogue scale, the size of six different portions of three different meals, with and without intent-to-eat instructions. Subjects with anorexia nervosa estimated the size of small and medium meal portions (but not large meal servings) as being significantly larger, compared to estimates of healthy controls. The overestimation of small meal portions by anorexia nervosa subjects was significantly greater in the intent-to-eat, compared to general, condition. These findings suggest that disturbed perceptions associated with anorexia nervosa not only include interoceptive awareness (i.e., body weight and shape), but also extend to external disorder-related objects such as meal portion size. Specific therapeutic interventions, such as training regarding meal portion evaluation, could address these difficulties. Copyright © 2013. Published by Elsevier Ltd.
Kaplan, SL; Edgar, JC; Ford, EG; Adgent, MA; Schall, JI; Kelly, A; Umbach, DM; Rogan, WJ; Stallings, VA; Darge, K
2017-01-01
Background Hormonally-sensitive organs in the neonate can change size within days of birth as circulating maternal estrogen wanes. Although several reports document the size of these organs through infancy, few focus on the near-birth period. Clinical and research evaluation of hormonal and genitourinary disorders would benefit from reference size standards. Objective We describe the size of the uterus, ovaries, testes, and breast buds in healthy term neonates. Materials and Methods As part of the Infant Feeding and Early Development (IFED) study, we sonographically measured the largest diameter of these organs in sagittal, transverse, and anterior-posterior planes for 194 female and 204 male newborns up to 3 days old. We calculated mean, median, and percentiles for longest axis length and for volume calculated from measured diameters. We evaluated size differences by laterality, sex, and race and compared our observations to published values. Results Mean length and volume, respectively, were: uterus, 4.2 cm and 10.0 cm3; ovary, 1.0 cm and 0.2 cm3; testis, 1.1 cm and 0.3 cm3 (0.4 cm3 Lambert volume); female breast bud, 1.2 cm and 0.7 cm3; male breast bud, 1.1 cm and 0.6 cm3. Breast buds were larger in females than males. Laterality differences were typically below the precision of clinical measurement. No significant race differences were detected. Conclusion Using data from our large cohort together with published values, we provide guidelines for evaluating the size of reproductive organs within the first 3 days of life. Discrepancies between our results and published values are likely attributable to technique. PMID:27580909
Self-diagnosis of damage in fibrous composites using electrical resistance measurements
NASA Astrophysics Data System (ADS)
Kang, Ji Ho; Paty, Spandana; Kim, Ran Y.; Tandon, G. P.
2006-03-01
The objective of this research was to develop a practical integrated approach using extracted features from electrical resistance measurements and coupled electromechanical models of damage, for in situ damage detection and sensing in carbon fiber reinforced plastic (CFRP) composite structures. To achieve this objective, we introduced specific known damage (in terms of type, size, and location) into CFRP laminates and established quantitative relationships with the electrical resistance measurements. For processing of numerous measurement data, an autonomous data acquisition system was devised. We also established a specimen preparation procedure and a method for electrode setup. Coupon and panel CFRP laminate specimens with several known damage were tested and post-processed with the measurement data. Coupon specimens with various sizes of artificial delaminations obtained by inserting Teflon film were manufactured and the resistance was measured. The measurement results showed that increase of delamination size led to increase of resistance implying that it is possible to sense the existence and size of delamination. Encouraged by the results of coupon specimens, we implemented the measurement system on panel specimens. Three different quasi-isotropic panels were designed and manufactured: a panel with artificial delamination by inserting Teflon film at the midplane, a panel with artificial delamination by inserting Teflon film between the second and third plies from the surface, and an undamaged panel. The first two panels were designed to determine the feasibility of detecting delamination using the developed measurement system. The third panel had no damage at first, and then three different sizes of holes were drilled at a chosen location. Panels were prepared using the established procedures with six electrode connections on each side making a total of twenty-four electrode connections for a panel. All possible pairs of electrodes were scanned and the resistance was measured for each pair. The measurement results showed the possibility of the established measurement system for an in-situ damage detection method for CFRP composite structures.
Lunar impact flashes - tracing the NEO size distribution
NASA Astrophysics Data System (ADS)
Avdellidou, Chrysa; Koschny, Detlef; NELIOTA Team
2017-10-01
Almost 20 years ago, we started to monitor the lunar surface with small telescopes to detect light flashes resulting from the hypervelocity collisions of meteoroids. The initial purpose was to understand the flux of impactors on Earth. The estimation of the flux of near Earth Objects (NEOs) is important not only for the protection of the human civilisation (meter-sized, see Chelyabinsk event in 2013), but also for the protection of the space assets (cm-sized objects). Apart from the NEO flux, the lunar surface helps the study of the impact events per se. The European Space Agency (ESA) is directing and funding lunar observations at 1.2 m Kryoneri telescope in Peloponnese, Greece. This telescope is equipped with a dichroic beam-splitter that directs the light onto two sCMOS cameras, that observe in visible and infrared wavelengths, using Rc and Ic Cousin filters respectively. Currently it is the largest telescope in the world that performs dedicated lunar impact flashes observations. We present the first flash observations in two bands, allowing us to measure flash temperatures for the first time. We find that the temperatures have a range that agrees with the theoretical approaches. Since the temperature can now be calculated, we have a more accurate estimation of the impactor’s mass and the size of the radiated ejecta plume.Having the Moon as a large-scale laboratory, new horizons are set towards the understanding of the nature of impacts, the impactor's material type and the energy partitioning, that is a constant puzzle in impact studies. This can now happen as more impact parameters can be determined and combined, such as the impactor’s mass and speed, flash luminosity, radiating volume, crater size when applicable etc. Future statistics can determine the different lunar regolith properties at different impact sites, especially during a meteoroid stream where the impactors share a common origin and possibly composition.
Watkins, Mike R; Oliver, Richard J
2017-07-01
Objectives The objectives were to examine the density, bubble size distribution and durability of sodium tetradecyl sulphate foam and the consistency of production of foam by a number of different operators using the Tessari method. Methods 1% and 3% sodium tetradecyl sulphate sclerosant foam was produced by an experienced operator and a group of inexperienced operators using either a 1:3 or 1:4 liquid:air ratio and the Tessari method. The foam density, bubble size distribution and foam durability were measured on freshly prepared foam from each operator. Results The foam density measurements were similar for each of the 1:3 preparations and for each of the 1:4 preparations but not affected by the sclerosant concentration. The bubble size for all preparations were very small immediately after preparation but progressively coalesced to become a micro-foam (<250 µm) after the first 30 s up until 2 min. Both the 1% and 3% solution foams developed liquid more rapidly when made in a 1:3 ratio (37 s) than in a 1:4 ratio (45 s) but all combinations took similar times to reach 0.4 ml liquid formation. For all the experiments, there was no statistical significant difference between operators. Conclusions The Tessari method of foam production for sodium tetradecyl sulphate sclerosant is consistent and reproducible even when made by inexperienced operators. The best quality foam with micro bubbles should be used within the first minute after production.
Mid- and long-term debris environment projections using the EVOLVE and CHAIN models
NASA Astrophysics Data System (ADS)
Eichler, Peter; Reynolds, Robert C.
1995-06-01
Results of debris environment projections are of great importance for the evaluation of the necessity and effectiveness of debris mitigation measures. EVOLVE and CHAIN are two models for debris environment projections that have been developed independently using different conceptual approaches. A comparison of results from these two models therefore provides a means of validating debris environment projections which they have made. EVOLVE is a model that requires mission model projections to describe future space operation; these projections include launch date, mission orbit altitude and inclimation, mission duration, vehicle size and mass, and classification as an object capable of experiencing breakup from on-board stored energy. EVOLVE describes the orbital debris environment by the orbital elements of the objects in the environment. CHAIN is an analytic model that bins the debris environemnt in size and altitude rather than following the orbit evolution of individual debris fragments. The altitude/size bins are coupled by the initial spreading of fragments by collisions and the following orbital decay behavior. A set of test cases covering a variety of space usage scenarios have been defined for the two models. In this paper, a comparison of the results will be presented and sources of disagreement identified and discussed. One major finding is that despite differences in the results of the two models, the basic tendencies of the environment projections are independent of modeled uncertainties, leading to the demand of debris mitigation measures--explosion suppression and de-orbit of rocket bodies and payloads after mission completion.
NASA Astrophysics Data System (ADS)
Yoshiura, Shintaro; Takahashi, Keitaro
2018-01-01
The dispersion measure (DM) of high-redshift (z ≳ 6) transient objects such as fast radio bursts can be a powerful tool to probe the intergalactic medium during the Epoch of Reionization. In this paper, we study the variance of the DMs of objects with the same redshift as a potential probe of the size distribution of ionized bubbles. We calculate the DM variance with a simple model with randomly distributed spherical bubbles. It is found that the DM variance reflects the characteristics of the probability distribution of the bubble size. We find that the variance can be measured precisely enough to obtain the information on the typical size with a few hundred sources at a single redshift.
Infrared detection, recognition and identification of handheld objects
NASA Astrophysics Data System (ADS)
Adomeit, Uwe
2012-10-01
A main criterion for comparison and selection of thermal imagers for military applications is their nominal range performance. This nominal range performance is calculated for a defined task and standardized target and environmental conditions. The only standardization available to date is STANAG 4347. The target defined there is based on a main battle tank in front view. Because of modified military requirements, this target is no longer up-to-date. Today, different topics of interest are of interest, especially differentiation between friend and foe and identification of humans. There is no direct way to differentiate between friend and foe in asymmetric scenarios, but one clue can be that someone is carrying a weapon. This clue can be transformed in the observer tasks detection: a person is carrying or is not carrying an object, recognition: the object is a long / medium / short range weapon or civil equipment and identification: the object can be named (e. g. AK-47, M-4, G36, RPG7, Axe, Shovel etc.). These tasks can be assessed experimentally and from the results of such an assessment, a standard target for handheld objects may be derived. For a first assessment, a human carrying 13 different handheld objects in front of his chest was recorded at four different ranges with an IR-dual-band camera. From the recorded data, a perception experiment was prepared. It was conducted with 17 observers in a 13-alternative forced choice, unlimited observation time arrangement. The results of the test together with Minimum Temperature Difference Perceived measurements of the camera and temperature difference and critical dimension derived from the recorded imagery allowed defining a first standard target according to the above tasks. This standard target consist of 2.5 / 3.5 / 5 DRI line pairs on target, 0.24 m critical size and 1 K temperature difference. The values are preliminary and have to be refined in the future. Necessary are different aspect angles, different carriage and movement.
Code of Federal Regulations, 2010 CFR
2010-04-01
... of an enforcement process which identifies vehicles of excessive size and weight and provides a... 23 Highways 1 2010-04-01 2010-04-01 false Objective. 657.7 Section 657.7 Highways FEDERAL HIGHWAY ADMINISTRATION, DEPARTMENT OF TRANSPORTATION ENGINEERING AND TRAFFIC OPERATIONS CERTIFICATION OF SIZE AND WEIGHT...
Mojarad, Nassiredin; Krishnan, Madhavi
2012-06-24
Measuring the size and charge of objects suspended in solution, such as dispersions of colloids or macromolecules, is a significant challenge. Measurements based on light scattering are inherently biased to larger entities, such as aggregates in the sample, because the intensity of light scattered by a small object scales as the sixth power of its size. Techniques that rely on the collective migration of species in response to external fields (electric or hydrodynamic, for example) are beset with difficulties including low accuracy and dispersion-limited resolution. Here, we show that the size and charge of single nanoscale objects can be directly measured with high throughput by analysing their thermal motion in an array of electrostatic traps. The approach, which is analogous to Millikan's oil drop experiment, could in future be used to detect molecular binding events with high sensitivity or carry out dynamic single-charge resolved measurements at the solid/liquid interface.
Design of piezoelectric transformer for DC/DC converter with stochastic optimization method
NASA Astrophysics Data System (ADS)
Vasic, Dejan; Vido, Lionel
2016-04-01
Piezoelectric transformers were adopted in recent year due to their many inherent advantages such as safety, no EMI problem, low housing profile, and high power density, etc. The characteristics of the piezoelectric transformers are well known when the load impedance is a pure resistor. However, when piezoelectric transformers are used in AC/DC or DC/DC converters, there are non-linear electronic circuits connected before and after the transformer. Consequently, the output load is variable and due to the output capacitance of the transformer the optimal working point change. This paper starts from modeling a piezoelectric transformer connected to a full wave rectifier in order to discuss the design constraints and configuration of the transformer. The optimization method adopted here use the MOPSO algorithm (Multiple Objective Particle Swarm Optimization). We start with the formulation of the objective function and constraints; then the results give different sizes of the transformer and the characteristics. In other word, this method is looking for a best size of the transformer for optimal efficiency condition that is suitable for variable load. Furthermore, the size and the efficiency are found to be a trade-off. This paper proposes the completed design procedure to find the minimum size of PT in need. The completed design procedure is discussed by a given specification. The PT derived from the proposed design procedure can guarantee both good efficiency and enough range for load variation.
Owning an overweight or underweight body: distinguishing the physical, experienced and virtual body.
Piryankova, Ivelina V; Wong, Hong Yu; Linkenauger, Sally A; Stinson, Catherine; Longo, Matthew R; Bülthoff, Heinrich H; Mohler, Betty J
2014-01-01
Our bodies are the most intimately familiar objects we encounter in our perceptual environment. Virtual reality provides a unique method to allow us to experience having a very different body from our own, thereby providing a valuable method to explore the plasticity of body representation. In this paper, we show that women can experience ownership over a whole virtual body that is considerably smaller or larger than their physical body. In order to gain a better understanding of the mechanisms underlying body ownership, we use an embodiment questionnaire, and introduce two new behavioral response measures: an affordance estimation task (indirect measure of body size) and a body size estimation task (direct measure of body size). Interestingly, after viewing the virtual body from first person perspective, both the affordance and the body size estimation tasks indicate a change in the perception of the size of the participant's experienced body. The change is biased by the size of the virtual body (overweight or underweight). Another novel aspect of our study is that we distinguish between the physical, experienced and virtual bodies, by asking participants to provide affordance and body size estimations for each of the three bodies separately. This methodological point is important for virtual reality experiments investigating body ownership of a virtual body, because it offers a better understanding of which cues (e.g. visual, proprioceptive, memory, or a combination thereof) influence body perception, and whether the impact of these cues can vary between different setups.
Owning an Overweight or Underweight Body: Distinguishing the Physical, Experienced and Virtual Body
Piryankova, Ivelina V.; Wong, Hong Yu; Linkenauger, Sally A.; Stinson, Catherine; Longo, Matthew R.; Bülthoff, Heinrich H.; Mohler, Betty J.
2014-01-01
Our bodies are the most intimately familiar objects we encounter in our perceptual environment. Virtual reality provides a unique method to allow us to experience having a very different body from our own, thereby providing a valuable method to explore the plasticity of body representation. In this paper, we show that women can experience ownership over a whole virtual body that is considerably smaller or larger than their physical body. In order to gain a better understanding of the mechanisms underlying body ownership, we use an embodiment questionnaire, and introduce two new behavioral response measures: an affordance estimation task (indirect measure of body size) and a body size estimation task (direct measure of body size). Interestingly, after viewing the virtual body from first person perspective, both the affordance and the body size estimation tasks indicate a change in the perception of the size of the participant's experienced body. The change is biased by the size of the virtual body (overweight or underweight). Another novel aspect of our study is that we distinguish between the physical, experienced and virtual bodies, by asking participants to provide affordance and body size estimations for each of the three bodies separately. This methodological point is important for virtual reality experiments investigating body ownership of a virtual body, because it offers a better understanding of which cues (e.g. visual, proprioceptive, memory, or a combination thereof) influence body perception, and whether the impact of these cues can vary between different setups. PMID:25083784
Perception while watching movies: Effects of physical screen size and scene type.
Troscianko, Tom; Meese, Timothy S; Hinde, Stephen
2012-01-01
Over the last decade, television screens and display monitors have increased in size considerably, but has this improved our televisual experience? Our working hypothesis was that the audiences adopt a general strategy that "bigger is better." However, as our visual perceptions do not tap directly into basic retinal image properties such as retinal image size (C. A. Burbeck, 1987), we wondered whether object size itself might be an important factor. To test this, we needed a task that would tap into the subjective experiences of participants watching a movie on different-sized displays with the same retinal subtense. Our participants used a line bisection task to self-report their level of "presence" (i.e., their involvement with the movie) at several target locations that were probed in a 45-min section of the movie "The Good, The Bad, and The Ugly." Measures of pupil dilation and reaction time to the probes were also obtained. In Experiment 1, we found that subjective ratings of presence increased with physical screen size, supporting our hypothesis. Face scenes also produced higher presence scores than landscape scenes for both screen sizes. In Experiment 2, reaction time and pupil dilation results showed the same trends as the presence ratings and pupil dilation correlated with presence ratings, providing some validation of the method. Overall, the results suggest that real-time measures of subjective presence might be a valuable tool for measuring audience experience for different types of (i) display and (ii) audiovisual material.
Urban light pollution - The effect of atmospheric aerosols on astronomical observations at night
NASA Astrophysics Data System (ADS)
Joseph, J. H.; Kaufman, Y. J.; Mekler, Y.
1991-07-01
The transfer of diffuse city light from a localized source through a dust-laden atmosphere with optical depth less than 0.5 has been analyzed in the source-observer plane on the basis of an approximate treatment. The effect on several types of astronomical observation at night has been studied, considering different size distributions and amounts as well as particle shapes of the aerosols. The analysis is made in terms of the signal-to-noise ratios for a given amount of aerosol. The model is applied to conditions at the Wise Astronomical Observatory in the Negev desert, and limiting backgrounds for spectroscopy, photometry, and photography of stars and extended objects have been calculated for a variety of signal-to-noise ratios. Applications to observations with different equipment at various distances from an urban area of any size are possible. Due to the use of signal-to-noise ratios, the conclusions are different for the different experimental techniques used in astronomy.
Urban light pollution - The effect of atmospheric aerosols on astronomical observations at night
NASA Technical Reports Server (NTRS)
Joseph, Joachim H.; Mekler, Yuri; Kaufman, Yoram J.
1991-01-01
The transfer of diffuse city light from a localized source through a dust-laden atmosphere with optical depth less than 0.5 has been analyzed in the source-observer plane on the basis of an approximate treatment. The effect on several types of astronomical observation at night has been studied, considering different size distributions and amounts as well as particle shapes of the aerosols. The analysis is made in terms of the signal-to-noise ratios for a given amount of aerosol. The model is applied to conditions at the Wise Astronomical Observatory in the Negev desert, and limiting backgrounds for spectroscopy, photometry, and photography of stars and extended objects have been calculated for a variety of signal-to-noise ratios. Applications to observations with different equipment at various distances from an urban area of any size are possible. Due to the use of signal-to-noise ratios, the conclusions are different for the different experimental techniques used in astronomy.
Time-to-Contact Judgments of an Approaching Object that Is Partially Concealed by an Occluder
ERIC Educational Resources Information Center
DeLucia, Patricia R.
2004-01-01
Prior studies of time-to-contact (TTC) focused on judgments of unoccluded approaching objects. P. R. DeLucia, M. K. Kaiser, J. M. Bush, L. E. Meyer, and B. T. Sweet (2003) showed that partial occlusion decreases an object's optical size and expansion rate and that the value of tau derived from the reduced optical size (relative rate of accretion;…
NASA Astrophysics Data System (ADS)
Li, Manchun; Ma, Lei; Blaschke, Thomas; Cheng, Liang; Tiede, Dirk
2016-07-01
Geographic Object-Based Image Analysis (GEOBIA) is becoming more prevalent in remote sensing classification, especially for high-resolution imagery. Many supervised classification approaches are applied to objects rather than pixels, and several studies have been conducted to evaluate the performance of such supervised classification techniques in GEOBIA. However, these studies did not systematically investigate all relevant factors affecting the classification (segmentation scale, training set size, feature selection and mixed objects). In this study, statistical methods and visual inspection were used to compare these factors systematically in two agricultural case studies in China. The results indicate that Random Forest (RF) and Support Vector Machines (SVM) are highly suitable for GEOBIA classifications in agricultural areas and confirm the expected general tendency, namely that the overall accuracies decline with increasing segmentation scale. All other investigated methods except for RF and SVM are more prone to obtain a lower accuracy due to the broken objects at fine scales. In contrast to some previous studies, the RF classifiers yielded the best results and the k-nearest neighbor classifier were the worst results, in most cases. Likewise, the RF and Decision Tree classifiers are the most robust with or without feature selection. The results of training sample analyses indicated that the RF and adaboost. M1 possess a superior generalization capability, except when dealing with small training sample sizes. Furthermore, the classification accuracies were directly related to the homogeneity/heterogeneity of the segmented objects for all classifiers. Finally, it was suggested that RF should be considered in most cases for agricultural mapping.
NASA Astrophysics Data System (ADS)
Alexandersen, Mike; Gladman, Brett; Kavelaars, J. J.; Petit, Jean-Marc; Gwyn, Stephen D. J.; Shankman, Cory J.; Pike, Rosemary E.
2016-11-01
The trans-Neptunian objects (TNOs) preserve evidence of planet building processes in their orbital and size distributions. While all populations show steep size distributions for large objects, a relative deficit of Neptunian trojans and scattering objects with diameters of D < 100 km has been detected. We investigated this deficit with a 32 square degree survey, in which we detected 77 TNOs that are brighter than a limiting r-band magnitude of 24.6. Our plutino sample (18 objects in 3:2 mean-motion resonance with Neptune) shows a deficit of D < 100 km objects, rejecting a single power-law size distribution at >99% confidence. Combining our survey with the Canada-France Ecliptic Plane Survey, we perform a detailed analysis of the allowable parameters for the plutino size distribution, including knees and divots. We surmise the existence of 9000 ± 3000 plutinos with an absolute magnitude of H r ≤ 8.66 and {37000}-10000+12000 with H r ≤ 10.0 (95% confidence). Our survey also discovered one temporary Uranian trojan, one temporary Neptunian trojan, and one stable Neptunian trojan, for which we estimate populations of {110}-100+500, {210}-200+900, and {150}-140+600 with H r ≤ 10.0, respectively. All three populations are thus less numerous than the main belt asteroids (592 asteroids with H r ≤ 10.0). With such population sizes, the temporary Neptunian trojans cannot be previously stable trojans diffusing out of the resonance now; they must be recently captured Centaurs or scattering objects. As the bias against the detection of objects grows with larger semimajor axes, our discovery of three 3:1 resonators and one 4:1 resonator adds to the growing evidence that the high-order resonances are far more populated than is typically predicted.
New Objective Refraction Metric Based on Sphere Fitting to the Wavefront
Martínez-Finkelshtein, Andreí
2017-01-01
Purpose To develop an objective refraction formula based on the ocular wavefront error (WFE) expressed in terms of Zernike coefficients and pupil radius, which would be an accurate predictor of subjective spherical equivalent (SE) for different pupil sizes. Methods A sphere is fitted to the ocular wavefront at the center and at a variable distance, t. The optimal fitting distance, topt, is obtained empirically from a dataset of 308 eyes as a function of objective refraction pupil radius, r0, and used to define the formula of a new wavefront refraction metric (MTR). The metric is tested in another, independent dataset of 200 eyes. Results For pupil radii r0 ≤ 2 mm, the new metric predicts the equivalent sphere with similar accuracy (<0.1D), however, for r0 > 2 mm, the mean error of traditional metrics can increase beyond 0.25D, and the MTR remains accurate. The proposed metric allows clinicians to obtain an accurate clinical spherical equivalent value without rescaling/refitting of the wavefront coefficients. It has the potential to be developed into a metric which will be able to predict full spherocylindrical refraction for the desired illumination conditions and corresponding pupil size. PMID:29104804
New Objective Refraction Metric Based on Sphere Fitting to the Wavefront.
Jaskulski, Mateusz; Martínez-Finkelshtein, Andreí; López-Gil, Norberto
2017-01-01
To develop an objective refraction formula based on the ocular wavefront error (WFE) expressed in terms of Zernike coefficients and pupil radius, which would be an accurate predictor of subjective spherical equivalent (SE) for different pupil sizes. A sphere is fitted to the ocular wavefront at the center and at a variable distance, t . The optimal fitting distance, t opt , is obtained empirically from a dataset of 308 eyes as a function of objective refraction pupil radius, r 0 , and used to define the formula of a new wavefront refraction metric (MTR). The metric is tested in another, independent dataset of 200 eyes. For pupil radii r 0 ≤ 2 mm, the new metric predicts the equivalent sphere with similar accuracy (<0.1D), however, for r 0 > 2 mm, the mean error of traditional metrics can increase beyond 0.25D, and the MTR remains accurate. The proposed metric allows clinicians to obtain an accurate clinical spherical equivalent value without rescaling/refitting of the wavefront coefficients. It has the potential to be developed into a metric which will be able to predict full spherocylindrical refraction for the desired illumination conditions and corresponding pupil size.
NASA Astrophysics Data System (ADS)
Teutsch, Michael; Saur, Günter
2011-11-01
Spaceborne SAR imagery offers high capability for wide-ranging maritime surveillance especially in situations, where AIS (Automatic Identification System) data is not available. Therefore, maritime objects have to be detected and optional information such as size, orientation, or object/ship class is desired. In recent research work, we proposed a SAR processing chain consisting of pre-processing, detection, segmentation, and classification for single-polarimetric (HH) TerraSAR-X StripMap images to finally assign detection hypotheses to class "clutter", "non-ship", "unstructured ship", or "ship structure 1" (bulk carrier appearance) respectively "ship structure 2" (oil tanker appearance). In this work, we extend the existing processing chain and are now able to handle full-polarimetric (HH, HV, VH, VV) TerraSAR-X data. With the possibility of better noise suppression using the different polarizations, we slightly improve both the segmentation and the classification process. In several experiments we demonstrate the potential benefit for segmentation and classification. Precision of size and orientation estimation as well as correct classification rates are calculated individually for single- and quad-polarization and compared to each other.
A shape-based segmentation method for mobile laser scanning point clouds
NASA Astrophysics Data System (ADS)
Yang, Bisheng; Dong, Zhen
2013-07-01
Segmentation of mobile laser point clouds of urban scenes into objects is an important step for post-processing (e.g., interpretation) of point clouds. Point clouds of urban scenes contain numerous objects with significant size variability, complex and incomplete structures, and holes or variable point densities, raising great challenges for the segmentation of mobile laser point clouds. This paper addresses these challenges by proposing a shape-based segmentation method. The proposed method first calculates the optimal neighborhood size of each point to derive the geometric features associated with it, and then classifies the point clouds according to geometric features using support vector machines (SVMs). Second, a set of rules are defined to segment the classified point clouds, and a similarity criterion for segments is proposed to overcome over-segmentation. Finally, the segmentation output is merged based on topological connectivity into a meaningful geometrical abstraction. The proposed method has been tested on point clouds of two urban scenes obtained by different mobile laser scanners. The results show that the proposed method segments large-scale mobile laser point clouds with good accuracy and computationally effective time cost, and that it segments pole-like objects particularly well.
Sizing of "Mother Ship and Catcher" Concepts for LEO Small Debris Capture
NASA Technical Reports Server (NTRS)
Bacon, John B.
2009-01-01
Most Low Earth Orbit (LEO) debris lies in a limited number of inclination "bands" associated with launch latitudes, or with specific useful orbit inclinations (such as polar orbits). Such narrow inclination bands generally have a uniform spread over all possible Right Ascensions of Ascending Node (RAANs), creating a different orbit plane for nearly every piece of debris. This complicates concept of rendezvous and capture for debris removal. However, a low-orbiting satellite will always phase in RAAN faster than debris objects in higher orbits at the same inclination, potentially solving the problem. Such a base can serve as a single space-based launch facility (a "mother ship") that can tend and then send tiny individual catcher devices for each debris object, as the facility drifts into the same RAAN as the higher object. This presentation will highlight characteristic system requirements of such an architecture, including structural and navigation requirements, power, mass and dV budgets for both the mother ship and the mass-produced common catcher devices that would clean out selected inclination bands. The altitude and inclination regime over which a band is to be cleared, the size distribution of the debris, and the inclusion of additional mission priorities all affect the sizing of the system. It is demonstrated that major LEO hazardous debris reductions can be realized in each band with a single LEO launch of a single mother ship, with simple attached catchers of total mass less than typical commercial LEO launch capability.
A Lagrangian analysis of cold cloud clusters and their life cycles with satellite observations
Esmaili, Rebekah Bradley; Tian, Yudong; Vila, Daniel Alejandro; Kim, Kyu-Myong
2018-01-01
Cloud movement and evolution signify the complex water and energy transport in the atmosphere-ocean-land system. Detecting, clustering, and tracking clouds as semi-coherent cluster objects enables study of their evolution which can complement climate model simulations and enhance satellite retrieval algorithms, where there are large gaps between overpasses. Using an area-overlap cluster tracking algorithm, in this study we examine the trajectories, horizontal extent, and brightness temperature variations of millions of individual cloud clusters over their lifespan, from infrared satellite observations at 30-minute, 4-km resolution, for a period of 11 years. We found that the majority of cold clouds were both small and short-lived and that their frequency and location are influenced by El Niño. More importantly, this large sample of individually tracked clouds shows their horizontal size and temperature evolution. Longer lived clusters tended to achieve their temperature and size maturity milestones at different times, while these stages often occurred simultaneously in shorter lived clusters. On average, clusters with this lag also exhibited a greater rainfall contribution than those where minimum temperature and maximum size stages occurred simultaneously. Furthermore, by examining the diurnal cycle of cluster development over Africa and the Indian subcontinent, we observed differences in the local timing of the maximum occurrence at different life cycle stages. Over land there was a strong diurnal peak in the afternoon while over the ocean there was a semi-diurnal peak composed of longer-lived clusters in the early morning hours and shorter-lived clusters in the afternoon. Building on regional specific work, this study provides a long-term, high-resolution, and global survey of object-based cloud characteristics. PMID:29744257
A Lagrangian analysis of cold cloud clusters and their life cycles with satellite observations.
Esmaili, Rebekah Bradley; Tian, Yudong; Vila, Daniel Alejandro; Kim, Kyu-Myong
2016-10-16
Cloud movement and evolution signify the complex water and energy transport in the atmosphere-ocean-land system. Detecting, clustering, and tracking clouds as semi-coherent cluster objects enables study of their evolution which can complement climate model simulations and enhance satellite retrieval algorithms, where there are large gaps between overpasses. Using an area-overlap cluster tracking algorithm, in this study we examine the trajectories, horizontal extent, and brightness temperature variations of millions of individual cloud clusters over their lifespan, from infrared satellite observations at 30-minute, 4-km resolution, for a period of 11 years. We found that the majority of cold clouds were both small and short-lived and that their frequency and location are influenced by El Niño. More importantly, this large sample of individually tracked clouds shows their horizontal size and temperature evolution. Longer lived clusters tended to achieve their temperature and size maturity milestones at different times, while these stages often occurred simultaneously in shorter lived clusters. On average, clusters with this lag also exhibited a greater rainfall contribution than those where minimum temperature and maximum size stages occurred simultaneously. Furthermore, by examining the diurnal cycle of cluster development over Africa and the Indian subcontinent, we observed differences in the local timing of the maximum occurrence at different life cycle stages. Over land there was a strong diurnal peak in the afternoon while over the ocean there was a semi-diurnal peak composed of longer-lived clusters in the early morning hours and shorter-lived clusters in the afternoon. Building on regional specific work, this study provides a long-term, high-resolution, and global survey of object-based cloud characteristics.
Masses, Dimensionless Kerr Parameters, and Emission Regions in GeV Gamma-Ray-loud Blazars
NASA Astrophysics Data System (ADS)
Xie, G.-Z.; Ma, L.; Liang, E.-W.; Zhou, S.-B.; Xie, Z.-H.
2003-11-01
We have compiled sample of 17 GeV γ-ray-loud blazars, for which rapid optical variability and γ-ray fluxes are well observed, from the literature. We derive estimates of the masses, the minimum Kerr parameters amin, and the size of the emission regions of the supermassive black holes (SMBHs) for the blazars in the sample from their minimum optical variability timescales and γ-ray fluxes. The results show that (1) the masses derived from the optical variability timescale (MH) are significantly correlated with the masses from the γ-ray luminosity (MKNH); (2) the values of amin of the SMBHs with masses MH>=108.3 Msolar (three out of 17 objects) range from ~0.5 to ~1.0, suggesting that these SMBHs are likely to be Kerr black holes. For the SMBHs with MH<108.3 Msolar, however, amin=0, suggesting that a nonrotating black hole model cannot be ruled out for these objects. In addition, the values of the size of the emission region, r*, for the two kinds of SMBHs are significantly different. For the SMBHs with amin>0, the sizes of the emission regions are almost within the horizon (2rG) and marginally bound orbit (4rG), while for those with amin=0 they are in the range (4.3-66.4)rG, extending beyond the marginally stable orbit (6rG). These results may imply that (1) the rotational state, the radiating regions, and the physical processes in the inner regions for the two kinds of SMBH are significantly different and (2) the emission mechanisms of GeV γ-ray blazars are related to the SMBHs in their centers but are not related to the two different kinds of SMBH.
A Lagrangian Analysis of Cold Cloud Clusters and Their Life Cycles With Satellite Observations
NASA Technical Reports Server (NTRS)
Esmaili, Rebekah Bradley; Tian, Yudong; Vila, Daniel Alejandro; Kim, Kyu-Myong
2016-01-01
Cloud movement and evolution signify the complex water and energy transport in the atmosphere-ocean-land system. Detecting, clustering, and tracking clouds as semi coherent cluster objects enables study of their evolution which can complement climate model simulations and enhance satellite retrieval algorithms, where there are large gaps between overpasses. Using an area-overlap cluster tracking algorithm, in this study we examine the trajectories, horizontal extent, and brightness temperature variations of millions of individual cloud clusters over their lifespan, from infrared satellite observations at 30-minute, 4-km resolution, for a period of 11 years. We found that the majority of cold clouds were both small and short-lived and that their frequency and location are influenced by El Nino. More importantly, this large sample of individually tracked clouds shows their horizontal size and temperature evolution. Longer lived clusters tended to achieve their temperature and size maturity milestones at different times, while these stages often occurred simultaneously in shorter lived clusters. On average, clusters with this lag also exhibited a greater rainfall contribution than those where minimum temperature and maximum size stages occurred simultaneously. Furthermore, by examining the diurnal cycle of cluster development over Africa and the Indian subcontinent, we observed differences in the local timing of the maximum occurrence at different life cycle stages. Over land there was a strong diurnal peak in the afternoon while over the ocean there was a semi-diurnal peak composed of longer-lived clusters in the early morning hours and shorter-lived clusters in the afternoon. Building on regional specific work, this study provides a long-term, high-resolution, and global survey of object-based cloud characteristics.
Montejo Carrasco, Pedro; Montenegro-Peña, Mercedes; López-Higes, Ramón; Estrada, Eduardo; Prada Crespo, David; Montejo Rubio, Christian; García Azorín, David
(i) To analyze if general cognitive performance, perceived health and depression are predictors of Subjective Memory Complaints (SMC) contrasting their effect sizes; (ii) to analyze the relationship between SMC and objective memory by comparing a test that measures memory in daily life and a classical test of associated pairs; (iii) to examine if different subgroups, formed according to the MFE score, might have different behaviors regarding the studied variables. Sample: 3921 community-dwelling people (mean age 70.41±4.70) without cognitive impairment. Consecutive non-probabilistic recruitment. Mini Cognitive Exam (MCE), daily memory Rivermead Behavioural Memory Test (RBMT), Paired Associates Learning (PAL), Geriatric Depression Scale (GDS), Nottingham Health Profile (NHP). Dependent variable: Memory Failures Everyday Questionnaire (MFE). Two different dimensions to explain SMC were found: One subjective (MFE, GDS, NHP) and other objective (RBMT, PAL, MCE), the first more strongly associated with SMC. SMC predictors were NHP, GDS, RBMT and PAL, in this order according to effect size. Considering MFE scores we subdivided the sample into three groups (low, medium, higher scores): low MFE group was associated with GDS; medium, with GDS, NPH and RBMT, and higher, with age as well. Effect size for every variable tended to grow as the MFE score was higher. SMC were associated with both health profile and depressive symptoms and, in a lesser degree, with memory and overall cognitive performance. In people with fewer SMC, these are only associated with depressive symptomatology. More SMC are associated with depression, poor health perception and lower memory. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
The uncrowded window of object recognition
Pelli, Denis G; Tillman, Katharine A
2009-01-01
It is now emerging that vision is usually limited by object spacing rather than size. The visual system recognizes an object by detecting and then combining its features. ‘Crowding’ occurs when objects are too close together and features from several objects are combined into a jumbled percept. Here, we review the explosion of studies on crowding—in grating discrimination, letter and face recognition, visual search, selective attention, and reading—and find a universal principle, the Bouma law. The critical spacing required to prevent crowding is equal for all objects, although the effect is weaker between dissimilar objects. Furthermore, critical spacing at the cortex is independent of object position, and critical spacing at the visual field is proportional to object distance from fixation. The region where object spacing exceeds critical spacing is the ‘uncrowded window’. Observers cannot recognize objects outside of this window and its size limits the speed of reading and search. PMID:18828191
Effects of Ocular Optics on Perceived Visual Direction and Depth
NASA Astrophysics Data System (ADS)
Ye, Ming
Most studies of human retinal image quality have specifically addressed the issues of image contrast, few have examined the problem of image location. However, one of the most impressive properties of human vision involves the location of objects. We are able to identify object location with great accuracy (less than 5 arcsec). The sensitivity we exhibit for image location indicates that any optical errors, such as refractive error, ocular aberrations, pupil decentration, etc., may have noticeable effects on perceived visual direction and distance of objects. The most easily observed effects of these optical factors is a binocular depth illusion called chromostereopsis in which equidistance colored objects appear to lie at the different distances. This dissertation covers a series of theoretical and experimental studies that examined the effects of ocular optics on perceived monocular visual direction and binocular chromostereopsis. Theoretical studies included development of an adequate eye model for predicting chromatic aberration, a major ocular aberration, using geometric optics. Also, a wave optical analysis is used to model the effects of defocus, optical aberrations, Stiles-Crawford effect (SCE) and pupil location on retinal image profiles. Experimental studies used psychophysical methods such as monocular vernier alignment tests, binocular stereoscopic tests, etc. This dissertation concludes: (1) With a decentered large pupil, the SCE reduces defocused image shifts compare to an eye without the SCE. (2) The blurred image location can be predicted by the centroid of the image profile. (3) Chromostereopsis with small pupils can be precisely accounted for by the interocular difference in monocular transverse chromatic aberration. (4) The SCE also plays an important role in the effect of pupil size on chromostereopsis. The reduction of chromostereopsis with large pupils can be accurately predicted by the interocular difference in monocular chromatic diplopia which is also reduced with large pupils. This supports the hypothesis that the effect of pupil size on chromostereopsis is due to monocular mechanisms.
Modulation of hand aperture during reaching in persons with incomplete cervical spinal cord injury.
Stahl, Victoria A; Hayes, Heather B; Buetefisch, Cathrin M; Wolf, Steven L; Trumbower, Randy D
2015-03-01
The intact neuromotor system prepares for object grasp by first opening the hand to an aperture that is scaled according to object size and then closing the hand around the object. After cervical spinal cord injury (SCI), hand function is significantly impaired, but the degree to which object-specific hand aperture scaling is affected remains unknown. Here, we hypothesized that persons with incomplete cervical SCI have a reduced maximum hand opening capacity but exhibit novel neuromuscular coordination strategies that permit object-specific hand aperture scaling during reaching. To test this hypothesis, we measured hand kinematics and surface electromyography from seven muscles of the hand and wrist during attempts at maximum hand opening as well as reaching for four balls of different diameters. Our results showed that persons with SCI exhibited significantly reduced maximum hand aperture compared to able-bodied (AB) controls. However, persons with SCI preserved the ability to scale peak hand aperture with ball size during reaching. Persons with SCI also used distinct muscle coordination patterns that included increased co-activity of flexors and extensors at the wrist and hand compared to AB controls. These results suggest that motor planning for aperture modulation is preserved even though execution is limited by constraints on hand opening capacity and altered muscle co-activity. Thus, persons with incomplete cervical SCI may benefit from rehabilitation aimed at increasing hand opening capacity and reducing flexor-extensor co-activity at the wrist and hand.
Modulation of hand aperture during reaching in persons with incomplete cervical spinal cord injury
Stahl, Victoria; Hayes, Heather B; Buetefisch, Cathrin; Wolf, Steven L; Trumbower, Randy D
2014-01-01
The intact neuromotor system prepares for object grasp by first opening the hand to an aperture that is scaled according to object size and then closing the hand around the object. After cervical spinal cord injury (SCI), hand function is significantly impaired, but the degree to which object-specific hand aperture scaling is affected remains unknown. Here we hypothesized that persons with incomplete cervical SCI have a reduced maximum hand opening capacity but exhibit novel neuromuscular coordination strategies that permit object-specific hand aperture scaling during reaching. To test this hypothesis, we measured hand kinematics and surface electromyography (EMG) from seven muscles of the hand and wrist during attempts at maximum hand opening as well as reaching for four balls of different diameters. Our results showed that persons with SCI exhibited significantly reduced maximum hand aperture compared to able-bodied (AB) controls. However, persons with SCI preserved the ability to scale peak hand aperture with ball size during reaching. Persons with SCI also used distinct muscle coordination patterns that included increased co-activity of flexors and extensors at the wrist and hand compared to AB controls. These results suggest that motor planning for aperture modulation is preserved even though execution is limited by constraints on hand opening capacity and altered muscle co-activity. Thus, persons with incomplete cervical SCI may benefit from rehabilitation aimed at increasing hand opening capacity and reducing flexor-extensor co-activity at the wrist and hand. PMID:25511164
The sonar aperture and its neural representation in bats.
Heinrich, Melina; Warmbold, Alexander; Hoffmann, Susanne; Firzlaff, Uwe; Wiegrebe, Lutz
2011-10-26
As opposed to visual imaging, biosonar imaging of spatial object properties represents a challenge for the auditory system because its sensory epithelium is not arranged along space axes. For echolocating bats, object width is encoded by the amplitude of its echo (echo intensity) but also by the naturally covarying spread of angles of incidence from which the echoes impinge on the bat's ears (sonar aperture). It is unclear whether bats use the echo intensity and/or the sonar aperture to estimate an object's width. We addressed this question in a combined psychophysical and electrophysiological approach. In three virtual-object playback experiments, bats of the species Phyllostomus discolor had to discriminate simple reflections of their own echolocation calls differing in echo intensity, sonar aperture, or both. Discrimination performance for objects with physically correct covariation of sonar aperture and echo intensity ("object width") did not differ from discrimination performances when only the sonar aperture was varied. Thus, the bats were able to detect changes in object width in the absence of intensity cues. The psychophysical results are reflected in the responses of a population of units in the auditory midbrain and cortex that responded strongest to echoes from objects with a specific sonar aperture, regardless of variations in echo intensity. Neurometric functions obtained from cortical units encoding the sonar aperture are sufficient to explain the behavioral performance of the bats. These current data show that the sonar aperture is a behaviorally relevant and reliably encoded cue for object size in bat sonar.
Bright, Leah; Secko, Michael; Mehta, Ninfa; Paladino, Lorenzo; Sinert, Richard
2014-04-01
Ultrasound is a readily available, non-invasive technique to visualize airway dimensions at the patient's bedside and possibly predict difficult airways before invasively looking; however, it has rarely been used for emergency investigation of the larynx. There is limited literature on the sonographic measurements of true vocal cords in adults and normal parameters must be established before abnormal parameters can be accurately identified. The primary objective of the following study is to identify the normal sonographic values of human true vocal cords in an adult population. A secondary objective is to determine if there is a difference in true vocal cord measurements in people with different body mass indices (BMIs). The third objective was to determine if there was a statistical difference in the measurements for both genders. True vocal cord measurements were obtained in healthy volunteers by ultrasound fellowship trained emergency medicine physicians using a high frequency linear transducer orientated transversely across the anterior surface of the neck at the level of the thyroid cartilage. The width of the true vocal cord was measured perpendicularly to the length of the cord at its mid-portion. This method was duplicated from a previous study to create a standard of measurement acquisition. A total of 38 subjects were enrolled. The study demonstrated no correlation between vocal cord measurements and patient's characteristics of height, weight, or BMI's. When accounting for vocal cord measurements by gender, males had larger BMI's and larger vocal cord measurements compared with females subjects with a statistically significant different in right vocal cord measurements for females compared with male subjects. No correlation was seen between vocal cord measurements and person's BMIs. In the study group of normal volunteers, there was a difference in size between the male and female vocal cord size.
Whitwell, Robert L; Goodale, Melvyn A; Merritt, Kate E; Enns, James T
2018-01-01
The two visual systems hypothesis proposes that human vision is supported by an occipito-temporal network for the conscious visual perception of the world and a fronto-parietal network for visually-guided, object-directed actions. Two specific claims about the fronto-parietal network's role in sensorimotor control have generated much data and controversy: (1) the network relies primarily on the absolute metrics of target objects, which it rapidly transforms into effector-specific frames of reference to guide the fingers, hands, and limbs, and (2) the network is largely unaffected by scene-based information extracted by the occipito-temporal network for those same targets. These two claims lead to the counter-intuitive prediction that in-flight anticipatory configuration of the fingers during object-directed grasping will resist the influence of pictorial illusions. The research confirming this prediction has been criticized for confounding the difference between grasping and explicit estimates of object size with differences in attention, sensory feedback, obstacle avoidance, metric sensitivity, and priming. Here, we address and eliminate each of these confounds. We asked participants to reach out and pick up 3D target bars resting on a picture of the Sander Parallelogram illusion and to make explicit estimates of the length of those bars. Participants performed their grasps without visual feedback, and were permitted to grasp the targets after making their size-estimates to afford them an opportunity to reduce illusory error with haptic feedback. The results show unequivocally that the effect of the illusion is stronger on perceptual judgments than on grasping. Our findings from the normally-sighted population provide strong support for the proposal that human vision is comprised of functionally and anatomically dissociable systems. Copyright © 2017 Elsevier Ltd. All rights reserved.
Solvent exchange method: a novel microencapsulation technique using dual microdispensers.
Yeo, Yoon; Chen, Alvin U; Basaran, Osman A; Park, Kinam
2004-08-01
A new microencapsulation method called the "solvent exchange method" was developed using a dual microdispenser system. The objective of this research is to demonstrate the new method and understand how the microcapsule size is controlled by different instrumental parameters. The solvent exchange method was carried out using a dual microdispenser system consisting of two ink-jet nozzles. Reservoir-type microcapsules were generated by collision of microdrops of an aqueous and a polymer solution and subsequent formation of polymer films at the interface between the two solutions. The prepared microcapsules were characterized by microscopic methods. The ink-jet nozzles produced drops of different sizes with high accuracy according to orifice size of a nozzle, flow rate of the jetted solutions, and forcing frequency of the piezoelectric transducers. In an individual microcapsule, an aqueous core was surrounded by a thin polymer membrane; thus, the size of the collected microcapsules was equivalent to that of single drops. The solvent exchange method based on a dual microdispenser system produces reservoir-type microcapsules in a homogeneous and predictable manner. Given the unique geometry of the microcapsules and mildness of the encapsulation process, this method is expected to provide a useful alternative to existing techniques in protein microencapsulation.
Polycyclic Aromatic Hydrocarbons and Infrared Astrophysics with Spitzer
NASA Technical Reports Server (NTRS)
Allamandola, L. J.; Hudgins, D. M.
2004-01-01
PAH spectral features are now being used as new probes of the ISM. PAH ionization states reflect the ionization balance of the medium while PAH size and structure reflect the energetic and chemical history of the medium. This paper will focus on recent applications of the NASA Ames PAH IR spectral Database to interpret astronomical observations made by the Spitzer Space telescope and other space based infrared instruments. Examples will be given showing how changes in the spectral characteristics of different objects reveal interstellar PAH characteristics such as structure, size and composition, as well as provide insight into the chemical history and physical nature of the emission zones.
Setting monitoring objectives for landscape-size areas
Craig M. Olson; Dean Angelides
2000-01-01
The setting of objectives for monitoring schemes for landscape-size areas should be a complex task in today's regulatory and sociopolitical atmosphere. The technology available today, the regulatory environment, and the sociopolitical considerations require multiresource inventory and monitoring schemes, whether tile ownership is industrial or for preservation....