Sample records for diffusion enzyme immunoassay

  1. Development of a novel ultrasensitive enzyme immunoassay for human glutamic acid decarboxylase 65 antibody.

    PubMed

    Numata, Satoshi; Katakami, Hideki; Inoue, Shinobu; Sawada, Hirotake; Hashida, Seiichi

    2016-07-01

    We developed a novel, ultrasensitive enzyme immunoassay (immune complex transfer enzyme immunoassay) for determination of glutamic acid decarboxylase autoantibody concentrations in serum samples from patients with type 2 diabetes. We developed an immune complex transfer enzyme immunoassay for glutamic acid decarboxylase autoantibody and measured glutamic acid decarboxylase autoantibody from 22 patients with type 1 diabetes, 29 patients with type 2 diabetes, and 32 healthy controls. A conventional ELISA kit identified 10 patients with type 1 diabetes and one patient with type 2 diabetes as glutamic acid decarboxylase autoantibody positive, whereas 15 patients with type 1 diabetes and six patients with type 2 diabetes were identified as glutamic acid decarboxylase autoantibody positive using immune complex transfer enzyme immunoassay. Immune complex transfer enzyme immunoassay is a highly sensitive and specific assay for glutamic acid decarboxylase autoantibody and might be clinically useful for diabetic onset prediction and early diagnosis. © The Author(s) 2016.

  2. 78 FR 13347 - Clinical Chemistry and Clinical Toxicology Devices Panel of the Medical Devices Advisory...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-02-27

    ... as isoniazid test strips. Isoniazid test strips are considered pre-Amendment devices since they were... as methotrexate enzyme immunoassays. Methotrexate enzyme immunoassays are considered pre- Amendment... and PCP radioimmunoassays. PCP enzyme immunoassays and PCP radioimmunoassays are considered pre...

  3. The management of isolated positive syphilis enzyme immunoassay results in HIV-negative patients attending a sexual health clinic.

    PubMed

    Thorley, Nicola; Adebayo, Michael; Smit, Erasmus; Radcliffe, Keith

    2016-08-01

    An unconfirmed positive treponemal enzyme immunoassay (enzyme immunoassay positive, Treponema pallidum particle agglutination negative and rapid plasma reagin negative) presents a clinical challenge to distinguish early syphilis infection from false-positive results. These cases are referred for syphilis line assay (INNO-LIA) and recalled for repeat syphilis serology. We performed a retrospective audit to establish the proportion of HIV-negative cases with unconfirmed positive enzyme immunoassay results, the proportion of these cases that received an INNO-LIA test and repeat syphilis serology testing and reviewed the clinical outcomes; 0.35% (80/22687) cases had an unconfirmed positive treponemal enzyme immunoassay result. Repeat syphilis serology was performed in 80% (64/80) cases, but no additional cases of syphilis were identified. Eighty-eight per cent (70/80) received an INNO-LIA test; 14% (5/37) unconfirmed enzyme immunoassay-positive cases with no prior history of syphilis were confirmed on INNO-LIA assay, supporting a diagnosis of latent syphilis. As a confirmatory treponemal test, the INNO-LIA assay may be more useful than repeat syphilis serological testing. © The Author(s) 2016.

  4. Kinetic analyses and performance of a colloidal magnetic nanoparticle based immunoassay dedicated to allergy diagnosis.

    PubMed

    Teste, Bruno; Kanoufi, Frédéric; Descroix, Stéphanie; Poncet, Pascal; Georgelin, Thomas; Siaugue, Jean-Michel; Petr, Jan; Varenne, Anne; Hennion, Marie-Claire

    2011-07-01

    In this paper, we demonstrate the possibility to use magnetic nanoparticles as immunosupports for allergy diagnosis. Most immunoassays used for immunosupports and clinical diagnosis are based on a heterogeneous solid-phase system and suffer from mass-transfer limitation. The nanoparticles' colloidal behavior and magnetic properties bring the advantages of homogeneous immunoassay, i.e., species diffusion, and of heterogeneous immunoassay, i.e., easy separation of the immunocomplex and free forms, as well as analyte preconcentration. We thus developed a colloidal, non-competitive, indirect immunoassay using magnetic core-shell nanoparticles (MCSNP) as immunosupports. The feasibility of such an immunoassay was first demonstrated with a model antibody and described by comparing the immunocapture kinetics using macro (standard microtiter plate), micro (microparticles) and nanosupports (MCSNP). The influence of the nanosupport properties (surface chemistry, antigen density) and of the medium (ionic strength, counter ion nature) on the immunocapture efficiency and specificity was then investigated. The performances of this original MCSNP-based immunoassay were compared with a gold standard enzyme-linked immunosorbent assay (ELISA) using a microtiter plate. The capture rate of target IgG was accelerated 200-fold and a tenfold lower limit of detection was achieved. Finally, the MCSNP-based immunoassay was successfully applied to the detection of specific IgE from milk-allergic patient's sera with a lower LOD and a good agreement (CV < 6%) with the microtiter plate, confirming the great potential of this analytical platform in the field of immunodiagnosis.

  5. Design of a single-step immunoassay principle based on the combination of an enzyme-labeled antibody release coating and a hydrogel copolymerized with a fluorescent enzyme substrate in a microfluidic capillary device.

    PubMed

    Wakayama, Hideki; Henares, Terence G; Jigawa, Kaede; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki

    2013-11-21

    A combination of an enzyme-labeled antibody release coating and a novel fluorescent enzyme substrate-copolymerized hydrogel in a microchannel for a single-step, no-wash microfluidic immunoassay is demonstrated. This hydrogel discriminates the free enzyme-conjugated antibody from an antigen-enzyme-conjugated antibody immunocomplex based on the difference in molecular size. A selective and sensitive immunoassay, with 10-1000 ng mL(-1) linear range, is reported.

  6. Enzyme linked immunoassay with stabilized polymer saccharide enzyme conjugates

    DOEpatents

    Callstrom, Matthew R.; Bednarski, Mark D.; Gruber, Patrick R.

    1997-01-01

    An improvement in enzyme linked immunoassays is disclosed wherein the enzyme is in the form of a water soluble polymer saccharide conjugate which is stable in hostile environments. The conjugate comprises the enzyme which is linked to the polymer at multiple points through saccharide linker groups.

  7. Enzyme linked immunoassay with stabilized polymer saccharide enzyme conjugates

    DOEpatents

    Callstrom, M.R.; Bednarski, M.D.; Gruber, P.R.

    1997-11-25

    An improvement in enzyme linked immunoassays is disclosed wherein the enzyme is in the form of a water soluble polymer saccharide conjugate which is stable in hostile environments. The conjugate comprises the enzyme which is linked to the polymer at multiple points through saccharide linker groups. 19 figs.

  8. DEVELOPMENT OF A CLASS-SELECTIVE ENZYME IMMUNOASSAY FOR URINARY PHENOLIC GLUCURONIDES. (R825433)

    EPA Science Inventory

    Class-selective immunoassays for the measurement of glucuronides in human urine can aid evaluation of human exposure to complex mixtures of xenobiotics. Therefore, an enzyme immunoassay (EIA) for the group-selective detection of phenolic Dual Electrophoresis Detection System for Rapid and Sensitive Immunoassays with Nanoparticle Signal Amplification

    NASA Astrophysics Data System (ADS)

    Zhang, Fangfang; Ma, Junjie; Watanabe, Junji; Tang, Jinlong; Liu, Huiyu; Shen, Heyun

    2017-02-01

    An electrophoretic technique was combined with an enzyme-linked immunosorbent assay (ELISA) system to achieve a rapid and sensitive immunoassay. A cellulose acetate filter modified with polyelectrolyte multilayer (PEM) was used as a solid substrate for three-dimensional antigen-antibody reactions. A dual electrophoresis process was used to induce directional migration and local condensation of antigens and antibodies at the solid substrate, avoiding the long diffusion times associated with antigen-antibody reactions in conventional ELISAs. The electrophoretic forces drove two steps in the ELISA process, namely the adsorption of antigen, and secondary antibody-labelled polystyrene nanoparticles (NP-Ab). The total time needed for dual electrophoresis-driven detection was just 4 min, nearly 2 h faster than a conventional ELISA system. Moreover, the rapid NP-Ab electrophoresis system simultaneously achieved amplification of the specific signal and a reduction in noise, leading to a more sensitive NP-Ab immunoassay with a limit of detection (LOD) of 130 fM, and wide range of detectable concentrations from 0.13 to 130 pM. These results suggest that the combination of dual electrophoresis detection and NP-Ab signal amplification has great potential for future immunoassay systems.

  9. Enzyme-linked immunosorbent assay for the quantitative/qualitative analysis of plant secondary metabolites.

    PubMed

    Sakamoto, Seiichi; Putalun, Waraporn; Vimolmangkang, Sornkanok; Phoolcharoen, Waranyoo; Shoyama, Yukihiro; Tanaka, Hiroyuki; Morimoto, Satoshi

    2018-01-01

    Immunoassays are antibody-based analytical methods for quantitative/qualitative analysis. Since the principle of immunoassays is based on specific antigen-antibody reaction, the assays have been utilized worldwide for diagnosis, pharmacokinetic studies by drug monitoring, and the quality control of commercially available products. Berson and Yalow were the first to develop an immunoassay, known as radioimmunoassay (RIA), for detecting endogenous plasma insulin [1], a development for which Yalow was awarded the Nobel Prize in Physiology or Medicine in 1977. Even today, after half a century, immunoassays are widely utilized with some modifications from the originally proposed system, e.g., radioisotopes have been replaced with enzymes because of safety concerns regarding the use of radioactivity, which is referred to as enzyme immunoassay/enzyme-linked immunosorbent assay (ELISA). In addition, progress has been made in ELISA with the recent advances in recombinant DNA technology, leading to increase in the range of antibodies, probes, and even systems. This review article describes ELISA and its applications for the detection of plant secondary metabolites.

  10. Kinase Activity Studied in Living Cells Using an Immunoassay

    ERIC Educational Resources Information Center

    Bavec, Aljos?a

    2014-01-01

    This laboratory exercise demonstrates the use of an immunoassay for studying kinase enzyme activity in living cells. The advantage over the classical method, in which students have to isolate the enzyme from cell material and measure its activity in vitro, is that enzyme activity is modulated and measured in living cells, providing a more…

  11. Nanoparticle-based sandwich electrochemical immunoassay for carbohydrate antigen 125 with signal enhancement using enzyme-coated nanometer-sized enzyme-doped silica beads.

    PubMed

    Tang, Dianping; Su, Biling; Tang, Juan; Ren, Jingjing; Chen, Guonan

    2010-02-15

    A novel nanoparticle-based electrochemical immunoassay of carbohydrate antigen 125 (CA125) as a model was designed to couple with a microfluidic strategy using anti-CA125-functionalized magnetic beads as immunosensing probes. To construct the immunoassay, thionine-horseradish peroxidase conjugation (TH-HRP) was initially doped into nanosilica particles using the reverse micelle method, and then HRP-labeled anti-CA125 antibodies (HRP-anti-CA125) were bound onto the surface of the synthesized nanoparticles, which were used as recognition elements. Different from conventional nanoparticle-based electrochemical immunoassays, the recognition elements of the immunoassay simultaneously contained electron mediator and enzyme labels and simplified the electrochemical measurement process. The sandwich-type immunoassay format was used for the online formation of the immunocomplex in an incubation cell and captured in the detection cell with an external magnet. The electrochemical signals derived from the carried HRP toward the reduction of H(2)O(2) using the doped thionine as electron mediator. Under optimal conditions, the electrochemical immunoassay exhibited a wide working range from 0.1 to 450 U/mL with a detection limit of 0.1 U/mL CA125. The precision, reproducibility, and stability of the immunoassay were acceptable. The assay was evaluated for clinical serum samples, receiving in excellent accordance with results obtained from the standard enzyme-linked immunosorbent assay (ELISA) method. Concluding, the nanoparticle-based assay format provides a promising approach in clinical application and thus represents a versatile detection method.

  12. Performance of a time-resolved fluorescence immunoassay for measuring varicella-zoster virus immunoglobulin G levels in adults and comparison with commercial enzyme immunoassays and Merck glycoprotein enzyme immunoassay.

    PubMed

    Maple, P A C; Gray, J; Breuer, J; Kafatos, G; Parker, S; Brown, D

    2006-02-01

    Highly sensitive and specific, quantitative assays are needed to detect varicella-zoster virus (VZV) immunoglobulin G in human sera, particularly for determining immune status and response following vaccination. A time-resolved fluorescence immunoassay (TRFIA) has been developed, and its performance was compared to that of two commercial enzyme immunoassays (EIAs) and Merck glycoprotein EIA (gpEIA). The TRFIA had equivalent sensitivity (97.8%) and high specificity (93.5%) in relation to gpEIA. A commercial (Behring) EIA compared favorably with TRFIA in terms of sensitivity (98.4%) but had lower specificity (80.7%). Another commercial EIA (Diamedix) had high specificity (97.1%) but low sensitivity (76.4%) compared to TRFIA if equivocal test results were treated as negative for VZV antibody. A novel feature of the TRFIA was that the cutoff was generated using population mixture modeling and was expressed in mIU/ml, as the assay was calibrated using the British standard VZV antibody.

  13. Improving of enzyme immunoassay for detection and quantification of the target molecules using silver nanoparticles

    NASA Astrophysics Data System (ADS)

    Syrvatka, Vasyl J.; Slyvchuk, Yurij I.; Rozgoni, Ivan I.; Gevkan, Ivan I.; Overchuk, Marta O.

    2014-02-01

    Modern routine enzyme immunoassays for detection and quantification of biomolecules have several disadvantages such as high cost, insufficient sensitivity, complexity and long-term execution. The surface plasmon resonance of silver nanoparticles gives reasons of creating new in the basis of simple, highly sensitive and low cost colorimetric assays that can be applied to the detection of small molecules, DNA, proteins and pollutants. The main aim of the study was the improving of enzyme immunoassay for detection and quantification of the target molecules using silver nanoparticles. For this purpose we developed method for synthesis of silver nanoparticles with hyaluronic acid and studied possibility of use these nanoparticles in direct determination of target molecules concentration (in particular proteins) and for improving of enzyme immunoassay. As model we used conventional enzyme immunoassays for determination of progesterone and estradiol concentration. We obtained the possibility to produce silver nanoparticles with hyaluronan homogeneous in size between 10 and 12 nm, soluble and stable in water during long term of storage using modified procedure of silver nanoparticles synthesis. New method allows to obtain silver nanoparticles with strong optical properties at the higher concentrations - 60-90 μg/ml with the peak of absorbance at the wavelength 400 nm. Therefore surface plasmon resonance of silver nanoparticles with hyaluronan and ultraviolet-visible spectroscopy provide an opportunity for rapid determination of target molecules concentration (especial protein). We used silver nanoparticles as enzyme carriers and signal enhancers. Our preliminary data show that silver nanoparticles increased absorbance of samples that allows improving upper limit of determination of estradiol and progesterone concentration.

  14. Sensitivity, specificity and comparison of three commercially available immunological tests in the diagnosis of Cryptosporidium species in animals.

    PubMed

    Danišová, Olga; Halánová, Monika; Valenčáková, Alexandra; Luptáková, Lenka

    The study was conducted to compare the specificity of immunological diagnostic methods used for the diagnosis of Cryptosporidium species capable of causing life-threatening infection in both immunosuppressed and immunocompetent patients. For the detection of Cryptosporidium species in 79 animals with diarrhoea, we used three Copro-antigen tests: RIDASCREEN ® Cryptosporidium test, Cryptosporidium 2nd Generation (ELISA) and RIDA ® QUICK Cryptosporidium. For immunoassays we used positive and negative samples detected by means of polymerase chain reaction and validated by sequencing and nested polymerase chain reaction to confirm the presence six different species of Cryptosporidium species. Prevalence of cryptosporidiosis in the entire group determined by enzyme immunoassay, enzyme linked immunosorbent assay, immuno-chromatographic test and polymerase chain reaction was 34.17%, 27.84%, 6.33% and 27.84%, respectively. Sensitivity of animal samples with enzyme immunoassay, enzyme linked immunosorbent assay, and immuno-chromatographic test was 63.6%, 40.9% and 22.7%, resp., when questionable samples were considered positive, whereas specificity of enzyme immunoassay, enzyme linked immunosorbent assay and immuno-chromatographic test was 75.9%, 78.9% and 100%, respectively. Positive predictive values and negative predictive values were different for all the tests. These differences results are controversial and therefore reliability and reproducibility of immunoassays as the only diagnostic method is questionable. The use of various Cryptosporidium species in diagnosis based on immunological testing and different results obtained by individual tests indicate potential differences in Copro-antigens produced by individual Cryptosporidium species. Copyright © 2017 Sociedade Brasileira de Microbiologia. Published by Elsevier Editora Ltda. All rights reserved.

  15. Development of a highly specific enzyme immunoassay for oxytocin and its use in plasma samples.

    PubMed

    Haraya, Shiomi; Karasawa, Koji; Sano, Yoshihiro; Ozawa, Kimiko; Kato, Nobumasa; Arakawa, Hidetoshi

    2017-01-01

    Background The peptide hormone oxytocin acts in the central nervous system and plays an important role in various complex social behaviours. We report the production of a high affinity and specificity antibody for oxytocin and its use in a highly sensitive enzyme immunoassay. Biotin that was chemically bound to oxytocin derivative containing zero to six lysines as bridge was the labelled antigen. Seven labelled antigens were used to develop a highly sensitive enzyme immunoassay. Methods Antioxytocin antiserum was obtained by immunization of oxytocin-bovine thyrogloblin conjugate to rabbit. Oxytocin sample was added to the second antibody-coated microtitre plate and allowed to react overnight at 4℃, then biotinylated oxytocin was added 1 h at 4℃, and horseradish peroxidase-labelled avidin was added and incubated for 1 h at room temperature. The plate was then washed. Horseradish peroxidase activity was measured by a colorimetric method using o-phenylenediamine (490 nm). Results The sensitivity of the enzyme immunoassay improved as the number of lysine residues increased; consequently, biotinylated oxytocin bridged with five lysines was used. A standard curve for oxytocin ranged from 1.0 to 1000 pg/assay. The detection limit of the assay was 2.36 pg, and the reproducibility was 3.6% as CV% ( n = 6). Cross-reactivity with vasopressin and vasotocin was less than 0.01%. Conclusion The sensitivity of the enzyme immunoassay could be improved by increasing the number of lysine residues on the biotin-labelled antigen. The proposed method is sensitive and more specific than conventional immunoassays for oxytocin and can be used to determine plasma oxytocin concentrations.

  16. False-negative syphilis treponemal enzyme immunoassay results in an HIV-infected case-patient.

    PubMed

    Katz, Alan R; Komeya, Alan Y; Tomas, Juval E

    2017-06-01

    We present a case report of a false-negative syphilis treponemal enzyme immunoassay test result in an HIV-infected male. While treponemal tests are widely considered to be more sensitive and specific than non-treponemal tests, our findings point to potential challenges using the reverse sequence syphilis screening algorithm.

  17. TRICLOSAN AND METHYL-TRICLOSAN MONITORING STUDY IN THE NORTHEAST OF SPAIN USING A MAGNETIC PARTICLE ENZYME IMMUNOASSAY AND CONFIRMATORY ANALYSIS BY GAS CHROMATOGRAPHY-MASS SPECTROMETRY

    USDA-ARS?s Scientific Manuscript database

    The occurrence of triclosan in the water environment around a Mediterranean region was investigated. Triclosan and methyl-triclosan content of ninety five environmental samples were screened using a magnetic particle enzyme immunoassay. Positive samples were confirmed by solid phase extraction (SPE...

  18. Protein adsorption in microengraving immunoassays.

    PubMed

    Song, Qing

    2015-10-16

    Microengraving is a novel immunoassay for characterizing multiple protein secretions from single cells. During the immunoassay, characteristic diffusion and kinetic time scales  and  determine the time for molecular diffusion of proteins secreted from the activated single lymphocytes and subsequent binding onto the glass slide surface respectively. Our results demonstrate that molecular diffusion plays important roles in the early stage of protein adsorption dynamics which shifts to a kinetic controlled mechanism in the later stage. Similar dynamic pathways are observed for protein adsorption with significantly fast rates and rapid shifts in transport mechanisms when  is increased a hundred times from 0.313 to 31.3. Theoretical adsorption isotherms follow the trend of experimentally obtained data. Adsorption isotherms indicate that amount of proteins secreted from individual cells and subsequently captured on a clean glass slide surface increases monotonically with time. Our study directly validates that protein secretion rates can be quantified by the microengraving immunoassay. This will enable us to apply microengraving immunoassays to quantify secretion rates from 10⁴-10⁵ single cells in parallel, screen antigen-specific cells with the highest secretion rate for clonal expansion and quantitatively reveal cellular heterogeneity within a small cell sample.

  19. Protein Adsorption in Microengraving Immunoassays

    PubMed Central

    Song, Qing

    2015-01-01

    Microengraving is a novel immunoassay forcharacterizing multiple protein secretions from single cells. During the immunoassay, characteristic diffusion and kinetic time scales τD and τK determine the time for molecular diffusion of proteins secreted from the activated single lymphocytes and subsequent binding onto the glass slide surface respectively. Our results demonstrate that molecular diffusion plays important roles in the early stage of protein adsorption dynamics which shifts to a kinetic controlled mechanism in the later stage. Similar dynamic pathways are observed for protein adsorption with significantly fast rates and rapid shifts in transport mechanisms when C0* is increased a hundred times from 0.313 to 31.3. Theoretical adsorption isotherms follow the trend of experimentally obtained data. Adsorption isotherms indicate that amount of proteins secreted from individual cells and subsequently captured on a clean glass slide surface increases monotonically with time. Our study directly validates that protein secretion rates can be quantified by the microengraving immunoassay. This will enable us to apply microengraving immunoassays to quantify secretion rates from 104–105 single cells in parallel, screen antigen-specific cells with the highest secretion rate for clonal expansion and quantitatively reveal cellular heterogeneity within a small cell sample. PMID:26501282

  1. Effects of Dehydroepiandrosterone Supplementation during Stressful Military Training: A Randomized, Controlled, Double-Blind Field Study

    DTIC Science & Technology

    2011-01-01

    DHEAS. All samples were assayed for salivary DHEA in duplicate using a highly sensitive enzyme immunoassay (Salimetrics, LLC). The test used 50ml of...p , 0.0001, n ¼ 39). Similarly, samples were assayed for salivary DHEAS in duplicate using a highly sensitive enzyme immuno- assay (Salimetrics, LLC...assayed for salivary testosterone. This was performed in duplicate using a highly sensitive enzyme immunoassay (Salimetrics, LLC). The test used 25ml of

  2. Total Triiodothyronine by Fluorescence Polarization Immunoassay (FPIA),

    DTIC Science & Technology

    Graves ’ disease . Traditionally, radioimmunoassays (RIA) have been employed for the determination of total T3. Enzyme immunoassays (EIA) and fluorescence immunoassays (FIA) have been developed for many of the analytes that formerly were measured using RIA. One variation of this new generation of immunoassays is fluorescence polarization. A fluorescence polarization immunoassay (FPIA) method for total T3 has been automated by adaptation to the TDx (Abbott, Chicago, IL) clinical analyzer. The TDx total T3 assay has been evaluated as a replacement for an RIA total T3

  3. Enzyme-catalysed deposition of ultrathin silver shells on gold nanorods: a universal and highly efficient signal amplification strategy for translating immunoassay into a litmus-type test.

    PubMed

    Yang, Xinjian; Gao, Zhiqiang

    2015-04-25

    On the basis of enzyme-catalysed reduction of silver ions and consequent deposition of ultrathin silver shells on gold nanorods, a highly efficient signal amplification method for immunoassay is developed. For a model analyte prostate-specific antigen, a 10(4)-fold improvement over conventional enzyme-linked immunosorbent assay is accomplished by leveraging on the cumulative nature of the enzymatic reaction and the sensitive response of plasnomic gold nanorods to the deposition the silver shells.

  4. [Automated analyzer of enzyme immunoassay].

    PubMed

    Osawa, S

    1995-09-01

    Automated analyzers for enzyme immunoassay can be classified by several points of view: the kind of labeled antibodies or enzymes, detection methods, the number of tests per unit time, analytical time and speed per run. In practice, it is important for us consider the several points such as detection limits, the number of tests per unit time, analytical range, and precision. Most of the automated analyzers on the market can randomly access and measure samples. I will describe the recent advance of automated analyzers reviewing their labeling antibodies and enzymes, the detection methods, the number of test per unit time and analytical time and speed per test.

  5. Silver nanoparticles deposited on graphene oxide for ultrasensitive surface-enhanced Raman scattering immunoassay of cancer biomarker.

    PubMed

    Yang, Lin; Zhen, Shu Jun; Li, Yuan Fang; Huang, Cheng Zhi

    2018-06-14

    Graphene oxide (GO) exhibits distinctive Raman scattering features for its high frequency D (disordered) and tangential modes (G-band), which are characteristically sharp at 1580 cm-1 and 1350 cm-1, respectively, but are too weak for sensitive quantitation purposes. By depositing silver nanoparticles on the surface of GO in this contribution, both D and G bands of GO become enhanced. The enzyme label of this method controls the dissolution of silver nanoparticles on the surface of GO through hydrogen peroxide which is produced by the oxidation of the enzyme substrate. With the dissolution of the silver nanoparticles a greatly decreased SERS signal of GO was obtained. This strategy involves dual signal amplification of the enzyme and nanocomposites to improve the detection sensitivity. As a proof of concept, prostate specific antigen (PSA), a biomarker for prostate cancer, is successfully detected as a target by forming a sandwich structure in immunoassay. The SERS immunoassay possesses excellent analytical performance in the range 0.5 pg mL-1 to 500 pg mL-1 with a limit of detection of 0.23 pg mL-1, making the detection of PSA serum samples from prostate cancer patients satisfactory, demonstrating that the sensitive enzyme-assisted dissolved AgNPs SERS immunoassay of PSA has potential applications in clinical diagnosis.

  6. Surveillance for Enteric Pathogens in a Case-Control Study of Acute Diarrhea in Western Kenya

    DTIC Science & Technology

    2012-11-01

    isolates was ascertained using the MicroScan WalkAway 40 Plus. An enzyme immunoassay kit was used to detect rotavirus , and ova and parasite...examination was conducted by micros- copy and an enzyme immunoassay. Results: Rotavirus (10.2% and 10.5%) and Shigella (11% and 8%) were isolated significantly...Keywords: Gastroenteritis, Protozoa, Rotavirus , Shigella, Escherichia coli, Antimicrobial resistance Introduction Diarrheal disease continues to be a

  7. Evaluation of automated enzyme immunoassays for five anticonvulsants and theophylline adapted to a centrifugal analyzer.

    PubMed

    Urquhart, N; Godolphin, W; Campbell, D J

    1979-05-01

    We report a clinical evaluation of the enzyme immunoassay (EMIT) performed with the GEMSAEC centrifugal analyzer as compared to gas-liquid and liquid chromatography for anticonvulsant drugs and theophylline, respectively. A good correlation was obtained for all drugs, although some difficulties were experienced with one lot of reagent for ethosuximide. The analyzer has an economic advantage if many samples are being analyzed for few drugs in each sample.

  8. Occurrence of nonspecific reactions among stool specimens tested by the Abbott TestPack rotavirus enzyme immunoassay.

    PubMed Central

    Lipson, S M; Leonardi, G P; Salo, R J; Schutzbank, T E; Kaplan, M H

    1990-01-01

    Sixty-five stool specimens obtained from children suffering from gastroenteritis were tested for the presence of antigen to rotavirus by the Abbott TestPack Rotavirus (TestPack) enzyme immunoassay kit. The Kallestad Pathfinder enzyme immunoassay, polyacrylamide gel electrophoresis, immune electron microscopy, and virus isolation were utilized as reference assays. Fifty-four specimens were in accord by TestPack and Kallestad Pathfinder. Among 11 discordant specimens positive with TestPack but negative by Kallestad Pathfinder, rotavirus was not identified by polyacrylamide gel electrophoresis, immune electron microscopy, or isolation in primary African green monkey kidney cell cultures. TestPack displayed a performance specificity of 83%. The inordinately high number of stool specimens reported as false-positive by TestPack precludes the incorporation of this antigen detection kit into our routine regimen of diagnostic virologic testing. Images PMID:2166074

  9. Isotachophoresis-Based Surface Immunoassay.

    PubMed

    Paratore, Federico; Zeidman Kalman, Tal; Rosenfeld, Tally; Kaigala, Govind V; Bercovici, Moran

    2017-07-18

    In the absence of amplification methods for proteins, the immune-detection of low-abundance proteins using antibodies is fundamentally limited by binding kinetic rates. Here, we present a new class of surface-based immunoassays in which protein-antibody reaction is accelerated by isotachophoresis (ITP). We demonstrate the use of ITP to preconcentrate and deliver target proteins to a surface decorated with specific antibodies, where effective utilization of the focused sample is achieved by modulating the driving electric field (stop-and-diffuse ITP mode) or applying a counter flow that opposes the ITP motion (counterflow ITP mode). Using enhanced green fluorescent protein (EGFP) as a model protein, we carry out an experimental optimization of the ITP-based immunoassay and demonstrate a 1300-fold improvement in limit of detection compared to a standard immunoassay, in a 6 min protein-antibody reaction. We discuss the design of buffer chemistries for other protein systems and, in concert with experiments, provide full analytical solutions for the two operation modes, elucidating the interplay between reaction, diffusion, and accumulation time scales and enabling the prediction and design of future immunoassays.

  10. Determination of atrazine in rainfall and surface water by enzyme immunoassay

    USGS Publications Warehouse

    Dankwardt, Andrea; Wüst, Susanne; Elling, Wolfram; Thurman, E. Michael; Hock, Bertold

    1994-01-01

    Rainwater and surface water from four sites in Germany (Bavaria and Lower Saxony) were analyzed for atrazine by enzyme immunoassay from June 1990 until October 1992. The limit of quantification of the immunoassay was 0.02 μg/L with a middle of the test at 0.2 μg/L. About 60 % of the samples contained measurable amounts of atrazine. Seasonal trends were observed, with the highest concentration in the summer months of up to 4 μg/L for rainwater and up to 15 μg/L for surface waters. The highest concentrations were found in agricultural areas, while in the investigated national parks up to 0.56 μg/L could be detected in rain water. This points to long-range atmospheric transport from agricultural areas to pristine national parks. Samples from forest stands usually showed higher atrazine concentrations than samples from open fields. Deposition rates of 10 – 50 μg/m2 · yr were observed in the national parks and 10–180 μg/m2 · yr at the agricultural sites. Comparison of results obtained by enzyme immunoassay and GC/MS showed a good correlation of r = 0.95.

  11. Chemiluminescence enzyme immunoassay using ProteinA-bacterial magnetite complex

    NASA Astrophysics Data System (ADS)

    Matsunaga, Tadashi; Sato, Rika; Kamiya, Shinji; Tanaka, Tsuyosi; Takeyama, Haruko

    1999-04-01

    Bacterial magnetic particles (BMPs) which have ProteinA expressed on their surface were constructed using magA which is a key gene in BMP biosynthesis in the magnetic bacterium Magnetospirillum sp. AMB-1. Homogenous chemiluminescence enzyme immunoassay using antibody bound ProteinA-BMP complexes was developed for detection of human IgG. A good correlation between the luminescence yield and the concentration of human IgG was obtained in the range of 1-10 3 ng/ml.

  12. Multicentric Evaluation of New Commercial Enzyme Immunoassays for the Detection of Immunoglobulin M and Total Antibodies against Hepatitis A Virus▿

    PubMed Central

    Arcangeletti, M. C.; Dussaix, E.; Ferraglia, F.; Roque-Afonso, A. M.; Graube, A.; Chezzi, C.

    2011-01-01

    A multicentric clinical study was conducted on representative sera from 1,738 European and U.S. subjects for the evaluation of new anti-hepatitis A virus enzyme immunoassays from Bio-Rad Laboratories. Comparison with reference DiaSorin S.p.A. tests confirmed the good performance of Bio-Rad assays (99.85% and 99.47% overall agreement in detecting total antibodies and IgM, respectively). PMID:21653739

  13. IMMUNOASSAY HUMAN EXPOSURE STUDIES

    EPA Science Inventory

    The Human Exposure Research Branch has developed several enzyme-linked immunosorbent assay (ELISA) methods to support human exposure assessment studies. Immunoassays to detect low levels (<10 ng/mL) of chlorpyrifos in food, track-in dirt and house dust have been applied to sam...

  14. SITE EVALUATION OF FIELD PORTABLE PENTACHLOROPHENOL IMMUNOASSAYS

    EPA Science Inventory

    Four pentachlorophenol (PCP) enzyme immunoassays for environmental analysis have been evaluated through the U.S. EPA Superfund Innovative Technology Evaluation (SITE) program. Three assays were formatted for on-site field use and one assay could be used in a field laboratory sett...

  15. Cytomegalovirus Antibody in Cerebrospinal Fluid of Schizophrenic Patients Detected by Enzyme Immunoassay

    NASA Astrophysics Data System (ADS)

    Fuller Torrey, E.; Yolken, Robert H.; Winfrey, C. Jack

    1982-05-01

    By means of enzyme immunoassay techniques to detect the presence of antibody to cytomegalovirus, the cerebrospinal fluid of 178 patients with schizophrenia, 17 patients with bipolar disorders, and 11 other psychiatric patients was compared with that of 79 neurological patients and 41 normal control subjects. The cerebrospinal fluid of 20 of the schizophrenic patients and 3 of the patients with bipolar disorders showed significant increases in immunoglobulin M antibody to cytomegalovirus; no difference was found in patients on or off psychotropic medications.

  16. Development of ochratoxin a in cereal by chemiluminescence enzyme immunoassay

    NASA Astrophysics Data System (ADS)

    Li, Min; Liu, Renrong; Zhu, Lixin; Chen, Zhenzhen

    2017-11-01

    A rapid, simple and sensitive chemiluminescence enzyme immunoassay method (CLEIA) was established to detect ochratoxin A (OTA) in cereal. Optimal conditions including antibody dilution ratio and enzyme conjugate, ionic strength, pH value and organic solvent. Established indirect competition inhibition curve to determine the linear working range, detection limit and recovery rate. Results: The 50% inhibitory concentration and the detection limit of the CLEIA were78.8pg/mL and 14.86 pg/mL, respectively, with a linear range of 0.015-0.4ng/mL. At 1∼4μpg/kg fortified levels in wheat, mean recoveries ranged from 67.47% to100.35%.

  17. Enhanced Colorimetric Immunoassay Accompanying with Enzyme Cascade Amplification Strategy for Ultrasensitive Detection of Low-Abundance Protein

    PubMed Central

    Gao, Zhuangqiang; Hou, Li; Xu, Mingdi; Tang, Dianping

    2014-01-01

    Methods based on enzyme labels have been developed for colorimetric immunoassays, but most involve poor sensitivity and are unsuitable for routine use. Herein, we design an enhanced colorimetric immunoassay for prostate-specific antigen (PSA) coupling with an enzyme-cascade-amplification strategy (ECAS-CIA). In the presence of target PSA, the labeled alkaline phosphatase on secondary antibody catalyzes the formation of palladium nanostructures, which catalyze 3,3′,5,5′-tetramethylbenzidine-H2O2 system to produce the colored products, thus resulting in the signal cascade amplification. Results indicated that the ECAS-CIA presents good responses toward PSA, and allows detection of PSA at a concentration as low as 0.05 ng mL−1. Intra- and inter-assay coefficients of variation are below 9.5% and 10.7%, respectively. Additionally, the methodology is validated for analysis of clinical serum specimens with consistent results obtained by PSA ELISA kit. Importantly, the ECAS-CIA opens a new horizon for protein diagnostics and biosecurity. PMID:24509941

  18. Sensitive detection of respiratory syncytial virus based on a dual signal amplified plasmonic enzyme-linked immunosorbent assay.

    PubMed

    Zhan, Lei; Wu, Wen Bi; Yang, Lin; Huang, Cheng Zhi

    2017-04-15

    The timely detection of infectious pathogen is critical in clinical early diagnosis and treatment of infectious diseases. Plasmonic enzyme-linked immunosorbent assay (ELISA), by means of enzyme-mediated growth or aggregation of AuNPs, has received considerable attention because it allows a naked-eye detection of target in very low numbers. In this work, a dual-signal amplified plasmonic ELISA combined the high loading capacity of magnetic beads with the establishing stimulation effect of zinc ion has been developed to detect RSV as a model pathogen based on alkaline phosphatase-triggered dispersion of aggregated AuNPs. In ideal conditions, the proposed immunoassay can conveniently distinguish the concentration of RSV in a range of 0.1-30 pg/mL. In addition, the limit of detection of RSV of this immunoassay exceeds that of conventional ELISA by about 50 times. The high sensitivity makes this approach a good alternative to existing colorimetric immunoassays for pathogen detection. Copyright © 2017 Elsevier B.V. All rights reserved.

  19. Molecularly Imprinted Polymer as an Antibody Substitution in Pseudo-immunoassays for Chemical Contaminants in Food and Environmental Samples.

    PubMed

    Chen, Chaochao; Luo, Jiaxun; Li, Chenglong; Ma, Mingfang; Yu, Wenbo; Shen, Jianzhong; Wang, Zhanhui

    2018-03-21

    The chemical contaminants in food and the environment are quite harmful to food safety and human health. Rapid, accurate, and cheap detection can effectively control the potential risks derived from these chemical contaminants. Among all detection methods, the immunoassay based on the specific interaction of antibody-analyte is one of the most widely used techniques in the field. However, biological antibodies employed in the immunoassay usually cannot tolerate extreme conditions, resulting in an unstable state in both physical and chemical profiles. Molecularly imprinted polymers (MIPs) are a class of polymers with specific molecular recognition abilities, which are highly robust, showing excellent operational stability under a wide variety of conditions. Recently, MIPs have been used in biomimetic immunoassays for chemical contaminants as an antibody substitute in food and the environment. Here, we reviewed these applications of MIPs incorporated in different analytical platforms, such as enzyme-linked immunosorbent assay, fluorescent immunoassay, chemiluminescent immunoassay, electrochemical immunoassay, microfluidic paper-based immunoassay, and homogeneous immunoassay, and discussed current challenges and future trends in the use of MIPs in biomimetic immunoassays.

  20. Evaluation of third generation anti-HCV enzyme immunoassays.

    PubMed

    Panigrahi, A K; Nayak, B; Dixit, R; Acharya, S K; Panda, S K

    1998-01-01

    The Hepatitis C Virus (HCV) is a major cause of post transfusion hepatitis. The introduction of HCV antibody screening has reduced the risk of post transfusion hepatitis significantly. However, the test is yet to be used routinely in blood banks of several developing countries with limited resources. We have developed an Enzyme immunoassay using synthetic peptides. The test was compared to seven commercial tests available in the Indian market. The test was evaluated using a panel of 90 sera which were chosen from an earlier panel based on detection of HCV RNA by Reverse Transcription Polymerase Chain Reaction RT-PCR. In case of any discrepancy the sera were further analysed by Line immunoassay (LIA). The sensitivity of the in house EIA was 90%. The specificity of the commercial EIAs varied.

  1. IMMUNOASSAY METHODS FOR MEASURING ATRAZINE AND 3,5,6-TRICHLORO-2-PYRIDINOL IN FOODS

    EPA Science Inventory

    This chapter describes the use of enzyme-linked immunosorbent assay (ELISA) methods for the analysis of two potential environmental contaminants in food sample media, atrazine and 3,5,6-trichloro-2-pyridinol (3,5,6-TCP). Two different immunoassay formats are employed: a magnetic...

  2. Plasma cortisol and 11-ketotestosterone enzyme immunoassay (EIA) kit validation for three fish species: the orange clownfish Amphiprion percula, the orangefin anemonefish Amphiprion chrysopterus and the blacktip reef shark Carcharhinus melanopterus.

    PubMed

    Mills, S C; Mourier, J; Galzin, R

    2010-08-01

    Commercially available enzyme immunoassay (EIA) kits were validated for measuring steroid hormone concentrations in blood plasma from three fish species: the orange clownfish Amphiprion percula, the orangefin anemonefish Amphiprion chrysopterus and the blacktip reef shark Carcharhinus melanopterus. A minimum of 5 microl plasma was required to estimate hormone concentrations with both kits. These EIA kits are a simple method requiring minimal equipment, for measuring hormone profiles under field conditions.

  3. A novel microfluidic microplate as the next generation assay platform for enzyme linked immunoassays (ELISA).

    PubMed

    Kai, Junhai; Puntambekar, Aniruddha; Santiago, Nelson; Lee, Se Hwan; Sehy, David W; Moore, Victor; Han, Jungyoup; Ahn, Chong H

    2012-11-07

    In this work we introduce a novel microfluidic enzyme linked immunoassays (ELISA) microplate as the next generation assay platform for unparalleled assay performances. A combination of microfluidic technology with standard SBS-configured 96-well microplate architecture, in the form of microfluidic microplate technology, allows for the improvement of ELISA workflows, conservation of samples and reagents, improved reaction kinetics, and the ability to improve the sensitivity of the assay by multiple analyte loading. This paper presents the design and characterization of the microfluidic microplate, and its application in ELISA.

  4. Automated homogeneous liposome immunoassay systems for anticonvulsant drugs.

    PubMed

    Kubotsu, K; Goto, S; Fujita, M; Tuchiya, H; Kida, M; Takano, S; Matsuura, S; Sakurabayashi, I

    1992-06-01

    We developed automated homogeneous immunoassays, based on immunolysis of liposomes, for measuring phenytoin, phenobarbital, and carbamazepine from serum. Liposome lysis was detected spectrophotometrically from entrapped glucose-6-phosphate dehydrogenase activity. The procedure was fully automated on a routine automated clinical analyzer. Within-run, between-run, dilution, and recovery tests showed good accuracies and reproducibilities. Bilirubin, hemoglobin, triglycerides, and Intrafat did not affect assay results. The results obtained by liposome immunoassays for phenytoin, phenobarbital, and carbamazepine correlated well with those obtained by enzyme-multiplied immunoassay (Syva EMIT) kits (r = 0.995, 0.986, and 0.988, respectively) and fluorescence polarization immunoassay (Abbott TDx) kits (r = 0.990, 0.991, and 0.975, respectively). The proposed method should be useful for monitoring anticonvulsant drug concentrations in blood.

  5. Immunodetection of the Bacteriocin Lacticin RM: Analysis of the Influence of Temperature and Tween 80 on Its Expression and Activity

    PubMed Central

    Keren, Tomer; Yarmus, Merav; Halevy, Galia; Shapira, Roni

    2004-01-01

    Immunoassays with specific antibodies offer higher sensitivity than do bioassays with indicator strains in the detection and quantification of several bacteriocins. Here we present the purification of lacticin RM and the production of specific polyclonal antibodies to a synthetic peptide resembling an internal fragment of the mature bacteriocin. The specificity and sensitivity of the generated polyclonal antibodies were evaluated in various immunoassays. The detection limits of lacticin RM were found to be 1.9, 0.16, and 0.18 μg ml−1 for Western blot, immuno-dot blot, and noncompetitive indirect enzyme-linked immunosorbent assays, respectively. Immunoassay sensitivities were 12.5-fold higher than that of the agar diffusion test (ADT). The production of lacticin RM showed temperature dependency, with 3, 4.2, 12.7, 28.9, 37.8, and 12 μg ml−1 at 37, 30, 20, 15, 10, and 4°C, respectively. Temperature-stability analysis demonstrated that lacticin RM is sensitive to mild temperature, but the loss of activity does not seem to result from protein degradation. Tween 80 increased the concentration of lacticin RM eightfold and probably affected the results of the ADT either by enhancing the activity of lacticin RM or by increasing the sensitivity of the indicator strain. The use of antibodies for the specific detection and quantification of lacticin RM can expand our knowledge of its production and stability, with important implications for further investigation and future application. PMID:15066801

  6. Application of microstructural optical waveguides with hollow core for enzyme immunoassay

    NASA Astrophysics Data System (ADS)

    Pidenko, Pavel S.; Pidenko, Sergei A.; Burmistrova, Natalia A.; Shuvalov, Andrei A.; Chibrova, Anastasiya A.; Skibina, Yulia S.; Goryacheva, Irina Y.

    2018-04-01

    Microstructural optical waveguides with the hollow core are actively studied as a promising support for heterogeneous immunoassay in development of new optical biosensor elements for medicine and biology. Overcoming of the limitations associated with the low sorption capacity of glass used for the waveguides production is a crucial step for this assay format. In this work the possibility of silanization of microstructural optical waveguides with the hollow core using (3-glycidyloxypropyl) trimethoxysilane and their further application to enzymatic immunoassay was studied.

  7. A comparison of five serological tests for bovine brucellosis.

    PubMed Central

    Dohoo, I R; Wright, P F; Ruckerbauer, G M; Samagh, B S; Robertson, F J; Forbes, L B

    1986-01-01

    Five serological assays: the buffered plate antigen test, the standard tube agglutination test, the complement fixation test, the hemolysis-in-gel test and the indirect enzyme immunoassay were diagnostically evaluated. Test data consisted of results from 1208 cattle in brucellosis-free herds, 1578 cattle in reactor herds of unknown infection status and 174 cattle from which Brucella abortus had been cultured. The complement fixation test had the highest specificity in both nonvaccinated and vaccinated cattle. The indirect enzyme immunoassay, if interpreted at a high threshold, also exhibited a high specificity in both groups of cattle. The hemolysis-in-gel test had a very high specificity when used in nonvaccinated cattle but quite a low specificity among vaccinates. With the exception of the complement fixation test, all tests had high sensitivities if interpreted at the minimum threshold. However, the sensitivities of the standard tube agglutination test and indirect enzyme immunoassay, when interpreted at high thresholds were comparable to that of the complement fixation test. A kappa statistic was used to measure the agreement between the various tests. In general the kappa statistics were quite low, suggesting that the various tests may detect different antibody isotypes. There was however, good agreement between the buffered plate antigen test and standard tube agglutination test (the two agglutination tests evaluated) and between the complement fixation test and the indirect enzyme immunoassay when interpreted at a high threshold. With the exception of the buffered plate antigen test, all tests were evaluated as confirmatory tests by estimating their specificity and sensitivity on screening-test positive samples.(ABSTRACT TRUNCATED AT 250 WORDS) PMID:3539295

  8. Optimization of condition for conjugation of enrofloxacin to enzymes in chemiluminescence enzyme immunoassay

    NASA Astrophysics Data System (ADS)

    Yu, Songcheng; Yu, Fei; Zhang, Hongquan; Qu, Lingbo; Wu, Yongjun

    2014-06-01

    In this study, in order to find out a proper method for conjugation of enrofloxacin to label enzymes, two methods were compared and carbodiimide condensation was proved to be better. The results showed that the binding ratio of enrofloxacin and alkaline phosphatase (ALP) was 8:1 and that of enrofloxacin and horseradish peroxidase (HRP) was 5:1. This indicated that conjugate synthesized by carbodiimide condensation was fit for chemiluminescence enzyme immunoassay (CLEIA). Furthermore, data revealed that dialysis time was an important parameter for conjugation and 6 days was best. Buffer to dilute conjugate had little effect on CLEIA. The storage condition for conjugates was also studied and it was shown that the conjugate was stable at 4 °C with no additive up to 30 days. These data were valuable for establishing CLEIA to quantify enrofloxacin.

  9. Novel photoluminescence enzyme immunoassay based on supramolecular host-guest recognition using L-arginine/6-aza-2-thiothymine-stabilized gold nanocluster.

    PubMed

    Wang, Youmei; Lu, Minghua; Tang, Dianping

    2018-06-30

    A new photoluminescence (PL) enzyme immunoassay was designed for sensitive detection of aflatoxin B 1 (AFB 1 ) via an innovative enzyme substrate, 6-aza-2-thiothymine-stabilized gold nanocluster (AAT-AuNC) with L-arginine. The enzyme substrate with strong PL intensity was formed through supramolecular host-guest assembly between guanidine group of L-arginine and AAT capped on the surface of AuNC. Upon arginase introduction, the captured L-arginine was hydrolyzed into ornithine and urea, thus resulting in the decreasing PL intensity. Based on this principle, a novel competitive-type immunoreaction was first carried out on AFB 1 -bovine serum albumin (AFB 1 -BSA) conjugate-coated microplate, using arginase-labeled anti-AFB 1 antibody as the competitor. Under the optimum conditions, the PL intensity increased with the increment of target AFB 1 , and allowed the detection of the analyte at concentrations as low as 3.2 pg mL -1 (ppt). Moreover, L-arginine-AAT-AuNC-based PL enzyme immunoassay afforded good reproducibility and acceptable specificity. In addition, the accuracy of this methodology, referring to commercial AFB 1 ELISA kit, was evaluated to analyze naturally contaminated or spiked peanut samples, giving well-matched results between two methods, thus representing a useful scheme for practical application in quantitative monitoring of mycotoxins in foodstuff. Copyright © 2018 Elsevier B.V. All rights reserved.

  10. [The efficiency of the enzyme immunoassay test system opisthorchiasis-CIC-EIA-best to detect circulating immune complexes containing opisthorchis antigens in the serum of patients with opisthorchiasis].

    PubMed

    Starkova, T V; Poletaeva, O G; Kovrova, E A; Krasovskaia, N N; Tkachenko, T N; Masiago, A V; Ofitserov, V I; Tereshchenko, A Iu

    2011-01-01

    The efficacy of a kit of Opisthorchiasis-CIC-EIA-Best reagents was evaluated using 270 sera from patients in the study and control groups. The kit showed a sufficient sensitivity (not less than 87.2%) and a high specificity (not less than 97.9%). The use of the above kit of the reagents for enzyme immunoassay in practical healthcare enables one to increase detection rates among the infested subjects on comprehensive examination of those with suspected opisthorchiasis.

  11. Comparison of the Vidas C. difficile GDH Automated Enzyme-Linked Fluorescence Immunoassay (ELFA) with Another Commercial Enzyme Immunoassay (EIA) (Quik Chek-60), Two Selective Media, and a PCR Assay for gluD for Detection of Clostridium difficile in Fecal Samples.

    PubMed

    Davies, K A; Berry, C E; Morris, K A; Smith, R; Young, S; Davis, T E; Fuller, D D; Buckner, R J; Wilcox, M H

    2015-06-01

    Prevention and management of Clostridium difficile infection (CDI) can be improved by rapid and reliable diagnostics. The Vidas C. difficile glutamate dehydrogenase assay had performance comparable to that of the Quik Chek-60 assay (overall agreement, 95%) and a sensitivity of >93%; thus, it is suitable as the first test in two-stage algorithms for a CDI diagnosis. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  12. The significance for epidemiological studies anti-measles antibody detection examined by enzyme immunoassay (EIA) and plaque reduction neutralization test (PRNT).

    PubMed

    Siennicka, Joanna; Częścik, Agnieszka; Trzcińska, Agnieszka

    2014-01-01

    The paper discusses the role of anti-measles antibodies for protection and significance for epidemiological studies determination of antibodies by different serological methods. The comparison of anti-measles virus antibodies levels measured by enzyme immunoassay (EIA) and Plaque Reduction Neutralization Test (PRNT) was described. It was found that the 200 mIU/ml of anti-measles activity measured by PRNT (level protection against symp- tomatic disease) is equivalent of 636 mIU/ml measured by EIA (Enzygnost®Anti-Measles Virus/IgG, Simens).

  13. Sources of variation in an enzyme-linked immunoassay of bluetongue virus in Culicoides variipennis (Diptera: Ceratopogonidae).

    PubMed

    Tabachnick, W J; Mecham, J O

    1991-03-01

    An enzyme-linked immunoassay for detecting bluetongue virus in infected Culicoides variipennis was evaluated using a nested analysis of variance to determine sources of experimental error in the procedure. The major source of variation was differences among individual insects (84% of the total variance). Storing insects at -70 degrees C for two months contributed to experimental variation in the ELISA reading (14% of the total variance) and should be avoided. Replicate assays of individual insects were shown to be unnecessary, since variation among replicate wells and plates was minor (2% of the total variance).

  14. Fabrication and Evaluation of Microfluidic Immunoassay Devices with Antibody-Immobilized Microbeads Retained in Porous Hydrogel Micropillars.

    PubMed

    Kasama, Toshihiro; Kaji, Noritada; Tokeshi, Manabu; Baba, Yoshinobu

    2017-01-01

    Due to the inherent characteristics including confinement of molecular diffusion and high surface-to-volume ratio, microfluidic device-based immunoassay has great advantages in cost, speed, sensitivity, and so on, compared with conventional techniques such as microtiter plate-based ELISA, latex agglutination method, and lateral flow immunochromatography. In this paper, we explain the detection of C-reactive protein as a model antigen by using our microfluidic immunoassay device, so-called immuno-pillar device. We describe in detail how we fabricated and used the immuno-pillar devices.

  15. Development and validation of a sensitive and fast chemiluminescent enzyme immunoassay for the detection of genetically modified maize.

    PubMed

    Roda, A; Mirasoli, M; Guardigli, M; Michelini, E; Simoni, P; Magliulo, M

    2006-03-01

    Proteins from the Cry 1 family, in particular Cry 1Ab, are commonly expressed in genetically modified Bt maize in order to control chewing insect pests. A sensitive chemiluminescent sandwich enzyme immunoassay for the detection of Cry1Ab protein from genetically modified Bt maize has been developed and validated. A Cry1Ab protein-specific antibody was immobilized on 96- or 384-well microtiter plates in order to capture the Cry1Ab toxin in the sample; the bound toxin was then detected by employing a second anti-Cry1Ab antibody and a horseradish peroxidase-labeled anti-antibody, followed by measurement of the enzyme activity with an enhanced chemiluminescent system. The chemiluminescent assay fulfilled all the requirements of accuracy and precision and exhibited limits of detection of a few pg mL(-1) Cry1Ab (3 or 5 pg mL(-1), depending on the assay format), which are significantly lower than that achievable using conventional colorimetric detection of peroxidase activity and also represent an improvement compared to previously developed Cry1Ab immunoassays. High-throughput analysis can be performed using the 384-well microtiter plate format immunoassay, which also allows one to reduce the consumption of samples and reagents. Validation of the assay, performed by analyzing certified reference materials, proved that the immunoassay is able to detect the presence of the Cry1Ab protein in certified reference samples containing as low as 0.1% of MON 810 genetically modified Bt maize. This value is below the threshold requiring mandatory labeling of foods containing genetically modified material according to the actual EU regulation.

  16. A competitive chemiluminescence enzyme immunoassay for rapid and sensitive determination of enrofloxacin

    NASA Astrophysics Data System (ADS)

    Yu, Fei; Wu, Yongjun; Yu, Songcheng; Zhang, Huili; Zhang, Hongquan; Qu, Lingbo; Harrington, Peter de B.

    With alkaline phosphatase (ALP)-adamantane (AMPPD) system as the chemiluminescence (CL) detection system, a highly sensitive, specific and simple competitive chemiluminescence enzyme immunoassay (CLEIA) was developed for the measurement of enrofloxacin (ENR). The physicochemical parameters, such as the chemiluminescent assay mediums, the dilution buffer of ENR-McAb, the volume of dilution buffer, the monoclonal antibody concentration, the incubation time, and other relevant variables of the immunoassay have been optimized. Under the optimal conditions, the detection linear range of 350-1000 pg/mL and the detection limit of 0.24 ng/mL were provided by the proposed method. The relative standard deviations were less than 15% for both intra and inter-assay precision. This method has been successfully applied to determine ENR in spiked samples with the recovery of 103%-96%. It showed that CLEIA was a good potential method in the analysis of residues of veterinary drugs after treatment of related diseases.

  17. Chemiluminescence Resonance Energy Transfer Competitive Immunoassay Employing Hapten-Functionalized Quantum Dots for the Detection of Sulfamethazine.

    PubMed

    Ma, Mingfang; Wen, Kai; Beier, Ross C; Eremin, Sergei A; Li, Chenglong; Zhang, Suxia; Shen, Jianzhong; Wang, Zhanhui

    2016-07-20

    We describe a new strategy for using chemiluminescence resonance energy transfer (CRET) by employing hapten-functionalized quantum dots (QDs) in a competitive immunoassay for detection of sulfamethazine (SMZ). Core/multishell QDs were synthesized and modified with phospholipid-PEG. The modified QDs were functionalized with the hapten 4-(4-aminophenyl-sulfonamido)butanoic acid. The CRET-based immunoassay exhibited a limit of detection for SMZ of 9 pg mL(-1), which is >4 orders of magnitude better than a homogeneous fluorescence polarization immunoassay and is 2 orders of magnitude better than a heterogeneous enzyme-linked immunosorbent assay. This strategy represents a simple, reliable, and universal approach for detection of chemical contaminants.

  18. Monoclonal antibodies to synthetic pyrethroids and method for detecting the same

    DOEpatents

    Stanker, Larry H.; Vanderlaan, Martin; Watkins, Bruce E.; Van Emon, Jeanette M.; Bigbee, Carolyn L.

    1992-01-01

    Methods are described for making specific monoclonal antibodies which may be used in a sensitive immunoassay for detection of synthetic pyrethroids in foods and environmental samples. Appropriate sample preparation and enzyme amplification of the immunoassay for this widely-used class of pesticides permits detection at low levels in laboratory and field tested samples.

  19. Method for immunodiagnostic detection of dioxins at low concentrations

    DOEpatents

    Vanderlaan, Martin; Stanker, Larry H.; Watkins, Bruce E.; Petrovic, Peter; Gorbach, Siegbert

    1995-01-01

    A method is described for the use of monoclonal antibodies in a sensitive immunoassay for halogenated dioxins and dibenzofurans in industrial samples which contain impurities. Appropriate sample preparation and selective enzyme amplification of the immunoassay sensitivity permits detection of dioxin contaminants in industrial or environmental samples at concentrations in the range of a few parts per trillion.

  20. Monoclonal antibodies to synthetic pyrethroids and method for detecting the same

    DOEpatents

    Stanker, L.H.; Vanderlaan, M.; Watkins, B.E.; Van Emon, J.M.; Bigbee, C.L.

    1992-04-28

    Methods are described for making specific monoclonal antibodies which may be used in a sensitive immunoassay for detection of synthetic pyrethroids in foods and environmental samples. Appropriate sample preparation and enzyme amplification of the immunoassay for this widely-used class of pesticides permits detection at low levels in laboratory and field tested samples. 6 figs.

  1. EVALUATION OF IMMUNOASSAY METHODS FOR DETERMINATION OF 3,5,6-TRICHLORO-2-PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    EPA Science Inventory

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by the RaPID (TM) commercial immunoassay testing ...

  2. A highly efficient colorimetric immunoassay using a nanocomposite entrapping magnetic and platinum nanoparticles in ordered mesoporous carbon.

    PubMed

    Kim, Moon Il; Ye, Youngjin; Woo, Min-Ah; Lee, Jinwoo; Park, Hyun Gyu

    2014-01-01

    Nanocomposite to achieve ultrafast immunoassay: a new synergistically integrated nanocomposite consisting of magnetic and platinum nanoparticles, simultaneously entrapped in mesoporous carbon, is developed as a promising enzyme mimetic candidate to achieve ultrafast colorimetric immunoassays. Using new assay system, clinically important target molecules, such as human epidermal growth factor receptor 2 (HER2) and diarrhea-causing rotavirus, can be detected in only 3 min at room temperature with high specificity and sensitivity. Copyright © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Optimization of condition for conjugation of enrofloxacin to enzymes in chemiluminescence enzyme immunoassay.

    PubMed

    Yu, Songcheng; Yu, Fei; Zhang, Hongquan; Qu, Lingbo; Wu, Yongjun

    2014-06-05

    In this study, in order to find out a proper method for conjugation of enrofloxacin to label enzymes, two methods were compared and carbodiimide condensation was proved to be better. The results showed that the binding ratio of enrofloxacin and alkaline phosphatase (ALP) was 8:1 and that of enrofloxacin and horseradish peroxidase (HRP) was 5:1. This indicated that conjugate synthesized by carbodiimide condensation was fit for chemiluminescence enzyme immunoassay (CLEIA). Furthermore, data revealed that dialysis time was an important parameter for conjugation and 6days was best. Buffer to dilute conjugate had little effect on CLEIA. The storage condition for conjugates was also studied and it was shown that the conjugate was stable at 4°C with no additive up to 30days. These data were valuable for establishing CLEIA to quantify enrofloxacin. Copyright © 2014 Elsevier B.V. All rights reserved.

  4. Magnetic Beads-based Bioelectrochemical Immunoassay of Polycyclic Aromatic Hydrocarbons

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lin, Ying-Ying; Liu, Guodong; Wai, Chien M.

    2007-07-01

    A simple, rapid, and sensitive bioelectrochemical immunoassay method based on magnetic beads (MBs) has been developed to detect polycyclic aromatic hydrocarbons (PAHs). The principle of this bioassay is based on a direct competitive enzyme-linked immunosorbent assay using PAH-antibody-coated MBs and horseradish peroxidase (HRP)-labeled PAH (HRP-PAH). A magnetic process platform was used to mix and shake the samples during the immunoreactions and to separate free and unbound reagents after the liquid-phase competitive immunoreaction among PAH-antibody-coated MBs, PAH analyte, and HRP-PAH. After a complete immunoassay, the HRP tracers attached to MBs were transferred to a substrate solution containing 3, 3´, 5, 5´-more » tetramethylbenzidine (TMB) and hydrogen peroxide (H2O2) for electrochemical detection. The voltammetric characteristics of the substrate were investigated, and the reduction peak current of TMB was used to quantify the concentration of PAH. The different parameters, including the amount of HRP-PAH conjugates, the enzyme catalytic reaction time, and the pH of the supporting electrolyte that governs the analytical performance of the immunoassay have been studied in detail and optimized. The detection limit of 50 pg mL-1 was obtained under optimum experimental conditions. The performance of this bioelectrochemical magnetic immunoassay was successfully evaluated with tap water spiked with PAHs, indicating that this convenient and sensitive technique offers great promise for decentralized environmental applications.« less

  5. Analysis of oxidative stress biomarkers using a simultaneous competitive/non-competitive micromosaic immunoassay.

    PubMed

    Murphy, Brian M; Dandy, David S; Henry, Charles S

    2009-04-27

    Immunoassays represent a core workhorse methodology for many applications ranging from clinical diagnostics to environmental monitoring. In traditional formats such as the enzyme linked immunosorbent assay (ELISA), analytes are measured singly or in small sets. As more biomarkers are identified for disease states, there is a need to develop methods that can measure multiple markers simultaneously. Immunoaffinity arrays are one such chemistry that can achieve multi-marker screening. Most arrays are performed in either competitive or non-competitive formats, where the former are used predominantly for small molecules and the later for macromolecules. To date, ELISA and immunoaffinity array methods have relied exclusively on one of these formats and not the other. Here an immunoaffinity array method capable of performing simultaneous competitive and non-competitive analysis generated using micromosaic immunoassay techniques is introduced for the analysis of metabolites and proteins. In this report, three markers of oxidative stress were used as a model system. The method described here demonstrates the simultaneous analysis of 3-nitrotyrosine, by indirect competitive immunoassay while the enzymes catalase and superoxide dismutase are analyzed by non-competitive sandwich immunoassay. The method requires less than 1 microL sample and 45 min for completion. Logistic curve fits and LOD (limits of detection) statistical analysis of the binding results are presented and show good agreement with published data for these antibody-antigen systems.

  6. Dried venous blood samples for the detection and quantification of measles IgG using a commercial enzyme immunoassay.

    PubMed Central

    Riddell, Michaela A.; Byrnes, Graham B.; Leydon, Jennie A.; Kelly, Heath A.

    2003-01-01

    OBJECTIVES: To determine whether samples of dried venous blood (DVB) were an acceptable alternative to serum for detecting measles-specific IgG in a commercial enzyme immunoassay. METHODS: Paired samples of serum and DVB were collected from 98 suspected cases of measles and 1153 schoolchildren in Victoria, Australia. All samples were tested using the Dade Behring Enzygnost Anti-Measles-Virus/IgG immunoassay. DVB samples were eluted using either the sample buffer provided with the kit or 5% dry milk powder in phosphate-buffered saline-Tween 20. FINDINGS: DVB samples eluted by sample buffer showed significantly better linear correlation to the serum samples than did DVB samples eluted in 5% dry milk in phosphate-buffered saline-Tween 20. To improve the comparability of serum and DVB samples an adjustment factor of 1.28 was applied to the optical density (OD) values of DVB. This adjustment also enabled quantification of the titre of measles IgG in mIU/ml directly from the OD value using the alpha calculation as specified by the kit protocol. For DVB samples stored for less than six months at 4 degrees C, the assay showed an overall sensitivity of 98.4% and a specificity of 97.2% compared with the results of serum testing. CONCLUSION: These results illustrate the potential for DVB samples to be widely used with the Dade Behring enzyme immunoassay system for determining the immunity of the individual and the population to the measles virus. PMID:14758429

  7. COMPARISON OF IMMUNOASSAY AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY METHODS FOR MEASURING 3,5,6-TRICHLORO-2PYRIDINOL IN MULTIPLE SAMPLE MEDIA

    EPA Science Inventory

    Two enzyme-linked immunosorbent assay (ELISA) methods were evaluated for the determination of 3,5,6-trichloro-2-pyridinol (3,5,6-TCP) in multiple sample media (dust, soil, food, and urine). The dust and soil samples were analyzed by a commercial RaPID immunoassay testing kit. ...

  8. Detection of RSV Antibodies in Human Plasma by Enzyme Immunoassays.

    PubMed

    Jadhao, Samadhan J; Anderson, Larry J

    2016-01-01

    Enzyme immunoassays (EIAs) to detect and quantify antibodies against respiratory syncytial virus (RSV) and RSV proteins in human plasma or sera are described. The first EIA uses RSV lysate antigens produced in HEp-2 cell line. The second EIA uses RSV F or G gene-expressed antigen in HEp-2 cells. The third EIA uses 30-amino acid synthetic peptides from central conserved region of G protein of RSV A2 or RSV B1 virus and a peptide from the SARS CoV nucleoprotein as a negative control peptide. All three EIAs have been evaluated for detecting and quantifying the respective antibodies in human sera or plasma.

  9. An enzyme immunoassay for rat growth hormone - Applications to the study of growth hormone variants

    NASA Technical Reports Server (NTRS)

    Farrington, Marianne A.; Hymer, W. C.

    1987-01-01

    A sensitive and specific competitive enzyme immunoassay for rat growth hormone (GH) is described and its use in the detection of GH variants is demonstrated. In the present assay, soluble GH and GH adsorbed to a solid-phase support compete for monkey anti-GH antibody binding sites. The immobilized antibody-GH complex is detected and quantified using goat antimonkey immunoglobin G covalently conjugated to horseradish peroxidase. It is noted that the assay can be performed in 27 hours and that sensitivities in the range of 0.19 to 25 ng can be obtained in the region of 10 to 90 percent binding.

  10. Competitive and blocking enzyme-linked immunoassay for detection of fetal bovine serum antibodies to bovine viral diarrhea virus.

    PubMed

    Katz, J B; Hanson, S K

    1987-02-01

    A competitive blocking enzyme-linked immunoassay (CELIA) was developed to detect bovine viral diarrhea virus (BVDV) antibodies in undiluted fetal bovine serum (FBS). The CELIA was based on competition of serum BVDV antibodies with biotin-labelled anti-BVDV immunoglobulins (Ig) for a limited quantity of solid-phase BVDV antigen. Antigen preparation was simple, FBS could be tested undiluted, and detergent-containing washes were unnecessary. A series of dilutions of postnatal bovine BVDV antiserum prepared in FBS and a set of 147 undiluted abbatoir FBS samples were tested by both CELIA and serum neutralization tests (SNT). CELIA results on both sets of specimens correlated positively with SNT titers (r = 0.99 and r = 0.85). Relative to the SNT, CELIA sensitivity was 100%; specificity was 76%. CELIA detected a level of BVDV antibody below the 1:2-titer threshold detectable with the SNT. Advantages, limitations, and theoretical differences between the CELIA and SNT are discussed. A similar comparison of CELIA with non-competitive enzyme-linked immunoassay approaches to BVDV serodiagnosis is made. It is concluded that the CELIA is valuable in selecting only BVDV-seronegative FBS for use in virologic cell culture media.

  11. Measurement of ring A-reduced progesterone metabolites by enzyme-linked immunoassay with colorimetric detection: baseline levels of six metabolites, including pregnanolone, in male rat plasma.

    PubMed

    Ocvirk, Rok; Franklin, Keith B J; Pearson Murphy, Beverley E

    2009-02-01

    The performance of an antiserum to progesterone and pregnane neurosteroids was assessed in two competitive assay setups: radioimmunoassay and enzyme-linked immunoassay with colorimetric detection, both with the same limit of detection of 2 pg. The enzyme-linked immunoassay was less labor-intensive and had better precision of measurement and was used to measure progesterone and six of its ring A-reduced metabolites in rat plasma. The measured levels of allopregnanolone and progesterone were in agreement with those reported previously when measured by gas chromatography/mass spectrometry and high-performance liquid chromatography coupled with radioimmunoassay and substantially lower than those previously measured by radioimmunoassay without chromatographic separation. Both isomers of dihydroprogesterone and all four isomers of pregnanolone were detected in rat plasma, indicating that progesterone is metabolized by reduction at the C5 and C3 position of the A ring, in both alpha and beta configurations. In addition to 5beta-dihydroprogesterone and isopregnanolone, which have not been previously detected in the rat, we found considerable amounts of pregnanolone, which is neuroactive, with similar potency to that of allopregnanolone but was previously thought not to be produced in rats.

  12. Enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence.

    PubMed Central

    Crouch, C F

    1995-01-01

    AIMS--To evaluate the clinical performance of enzyme immunoassays for IgG and IgM antibodies to Toxoplasma gondii based on enhanced chemiluminescence. METHODS--Classification of routine clinical samples from the originating laboratories was compared with that obtained using the chemiluminescence based assays. Resolution of discordant results was achieved by testing in alternative enzyme immunoassays (IgM) or by an independent laboratory using the dye test (IgG). RESULTS--Compared with resolved data, the IgM assay was found to be highly specific (100%) with a cut off selected to give optimal performance with respect to both the early detection of specific IgM and the detection of persistent levels of specific IgM (sensitivity 98%). Compared with resolved data, the IgG assay was shown to have a sensitivity and a specificity of 99.4%. CONCLUSIONS--The Amerlite Toxo IgM assay possesses high levels of sensitivity and specificity. Assay interference due to rheumatoid factor like substances is not a problem. The Amerlite Toxo IgG assay possesses good sensitivity and specificity, but is less sensitive for the detection of seroconversion than methods detecting both IgG and IgM. PMID:7560174

  13. Immunoassays for pesticide monitoring

    NASA Astrophysics Data System (ADS)

    Wengatz, Ingrid; Szurdoki, Ferenc; Swamy, Anand R.; Evans, Lawrence, III; Patonay, Gabor; Stimmann, Eric; Delwiche, Michael; Stoutamire, Donald; Gee, Shirley J.; Hammock, Bruce D.

    1995-05-01

    This study compares two formats of rapid assays for the detection of pesticides (bromacil and pyrethroid based metabolites): enzyme linked immunosorbent assay (ELISA) and immunoassay with near-infrared (NIR) fluorescence detection. NIR dye immunoassay (NIRDIA) measurements were carried out by using two different instruments, both having a silicon photodiode as the detector and a laser diode for excitation. ELISA and NIRDIA were performed in a tracer format, where the specific antibody is bound to the surface of a microtiter plate well and the tracer with enzyme or fluorescent dye label competes with the analyte for the antibody binding site. It was demonstrated that the NIRDIA is at least as sensitive as the ELISA. Both assays detect pesticides in the (mu) g/L (ppb) range. Hapten- macromolecule-NIR dye-conjugates have been synthesized with various biopolymers (e.g., proteins) as carriers. The use of carrier macromolecules enables convenient purification of the cyanine dye derivatives. The mild conjugation method of the dye is based on isothiocyanate chemistry.

  14. Two enzyme immunoassays to screen for 2,4-dichlorophenoxyacetic acid in water.

    PubMed

    Fleeker, J

    1987-01-01

    Two solid-phase enzyme immunoassays were developed to measure 2,4-dichlorophenoxyacetic acid (2,4-D), using 2 sets of structurally distinct immunogens and enzyme ligands. The 2,4-D analog, 2-methyl-4-chlorophenoxyacetic acid (MCPA), gave a similar response with both methods, whereas other phenoxy herbicides cross-reacted differently. In method A, the aromatic moiety of 2,4-D was distal from the carrier protein and labeled enzyme, whereas in method B, the acetic acid portion of the herbicide was distal. The use of both methods to screen for this herbicide in ground water and municipal and river water reduced the number of false-positive responses. Water sources having a low background response could be monitored with either method alone. When a concentration step, with disposable C18 extraction columns, was used, the limit of sensitivity was 5 micrograms/L. Method A was the more sensitive of the 2 methods with a limit of detection of 10 micrograms/L without the concentration step.

  15. Plasma myelin basic protein assay using Gilford enzyme immunoassay cuvettes.

    PubMed

    Groome, N P

    1981-10-01

    The assay of myelin basic protein in body fluids has potential clinical importance as a routine indicator of demyelination. Preliminary details of a competitive enzyme immunoassay for this protein have previously been published by the author (Groome, N. P. (1980) J. Neurochem. 35, 1409-1417). The present paper now describes the adaptation of this assay for use on human plasma and various aspects of routine data processing. A commercially available cuvette system was found to have advantages over microtitre plates but required a permuted arrangement of sample replicates for consistent results. For dose interpolation, the standard curve could be fitted to a three parameter non-linear equation by regression analysis or linearised by the logit/log transformation.

  16. Droplet-Free Digital Enzyme-Linked Immunosorbent Assay Based on a Tyramide Signal Amplification System.

    PubMed

    Akama, Kenji; Shirai, Kentaro; Suzuki, Seigo

    2016-07-19

    Digital enzyme-linked immunosorbent assay (ELISA) is a single molecule counting technology and is one of the most sensitive immunoassay methods. The key aspect of this technology is to concentrate enzyme reaction products from a single target molecule in femtoliter droplets. This study presents a novel Digital ELISA that does not require droplets; instead, enzyme reaction products are concentrated using a tyramide signal amplification system. In our method, tyramide substrate reacts with horseradish peroxidase (HRP) labeled with an immunocomplex on beads, and the substrate is converted into short-lived radical intermediates. By adjusting the bead concentration in the HRP-tyramide reaction and conducting the reaction using freely moving beads, tyramide radicals are deposited only on beads labeled with HRP and there is no diffusion to other beads. Consequently, the fluorescence signal is localized on a portion of the beads, making it possible to count the number of labeled beads digitally. The performance of our method was demonstrated by detecting hepatitis B surface antigen with a limit of detection of 0.09 mIU/mL (139 aM) and a dynamic range of over 4 orders of magnitude. The obtained limit of detection represents a >20-fold higher sensitivity than conventional ELISA. Our method has potential applications in simple in vitro diagnostic systems for detecting ultralow concentrations of protein biomarkers.

  17. Establishment of a Simple and Convenient Method for Folic Acid Enzyme Chemiluminescence Immunoassay

    NASA Astrophysics Data System (ADS)

    Liu, Ting; Zeng, Ling; Yu, Zhengwei; Yang, Yanfei; Qu, Yunhuan

    2018-01-01

    The enzyme chemiluminescence new immunoassay for folic acid (FA) was established by competition model. Add FA samples to a microtiter plate precoated with the goat anti-mouse IgG firstly, then add enzyme abled FA and FA monoclonal antibody (McAb). The values of CLIA were measured to reflect the quantity of FA. The limit of detection(LOD) of assay is 0.37ng/mL. The assay shows good correlation during 1∼30 ng/mL with correlation coefficient 0.9976. The intra- and inter-assay coefficients of variation are 4.8 % ∼ 7.3 % and 6.1 % ∼ 12.2 %, respectively. The recovery of folic acid in serum is 90.4 %∼113.2 %. Compared with determine value clinically in chemiluminescence immunoassay kit from Roche company, the correlative equation is y = 0.9689x + 0.0228, and correlation coefficient is 0.9780. Various components and kit overall show good stabilities. This method is simple and convenient, and has low LOD value. The method has overcome the shortcomings of the present references. It is easy to apply and has broad clinical application prospect. It lays an experimental foundation for the preparation of Mc Ab against folic acid and the development of domestic kit.

  18. Rapid quantitative analysis of 8-iso-prostaglandin-F(2alpha) using liquid chromatography-tandem mass spectrometry and comparison with an enzyme immunoassay method.

    PubMed

    Dahl, Jeffrey H; van Breemen, Richard B

    2010-09-15

    A rapid liquid chromatography-tandem mass spectrometry (LC-MS/MS) assay was developed for the measurement of urinary 8-iso-prostaglandin F(2alpha) (8-iso-PGF(2alpha)), a biomarker of lipid peroxidation. Because urine contains numerous F(2) prostaglandin isomers, each with identical mass and similar mass spectrometric fragmentation patterns, chromatographic separation of 8-iso-PGF(2alpha) from its isomers is necessary for its quantitative analysis using MS/MS. We were able to achieve this separation using an isocratic LC method with a run time of less than 9min, which is at least threefold faster than previous methods, while maintaining sensitivity, accuracy, precision, and reliability. The limits of detection and quantitation were 53 and 178pg/ml urine, respectively. We compared our method with a commercially available affinity purification and enzyme immunoassay kit and found both assays to be in agreement. Despite the high sensitivity of the enzyme immunoassay method, it is more expensive and has a narrower dynamic range than LC-MS/MS. Our method was optimized for rapid measurement of 8-iso-PGF(2alpha) in urine, and it is ideally suited for clinical sample analysis. 2010 Elsevier Inc. All rights reserved.

  19. Magnetic Affinity Enzyme-Linked Immunoassay for Diagnosis of Schistosomiasis Japonicum in Persons with Low-Intensity Infection

    PubMed Central

    Yu, Qin; Yang, Hai; Feng, Youmei; Zhu, Yanhong; Yang, Xiangliang

    2012-01-01

    Most schistosome-endemic areas in China are characterized by low-intensity infections that are independent of prevalence. To establish an effective diagnostic method, we developed a magnetic affinity enzyme-linked immunoassay based on soluble egg antigens (SEA-MEIA) for diagnosing schistosomiasis in persons with low-intensity infection with Schistosoma japonicum by comparing it with a conventional enzyme-linked immunosorbent assay (ELISA). Our results showed that the SEA-MEIA had a higher sensitivity and greater precision in the diagnosis of low-intensity S. japonicum infections than the ELISA. In addition, when we used Pearson's correlation in associating SEA-MEIA with ELISA, a significant correlation existed between the two assays (r = 0.845, P < 0.001). Our data indicated that SEA-MEIA, with a higher sensitivity and greater ease of performance, would be valuable for diagnosis of schistosomiasis japonicum in persons with low-intensity infections. PMID:22869635

  20. A Compact Immunoassay Platform Based on a Multicapillary Glass Plate

    PubMed Central

    Xue, Shuhua; Zeng, Hulie; Yang, Jianmin; Nakajima, Hizuru; Uchiyama, Katsumi

    2014-01-01

    A highly sensitive, rapid immunoassay performed in the multi-channels of a micro-well array consisting of a multicapillary glass plate (MCP) and a polydimethylsiloxane (PDMS) slide is described. The micro-dimensions and large surface area of the MCP permitted the diffusion distance to be decreased and the reaction efficiency to be increased. To confirm the concept of the method, human immunoglobulin A (h-IgA) was measured using both the proposed immunoassay system and the traditional 96-well plate method. The proposed method resulted in a 1/5-fold decrease of immunoassay time, and a 1/56-fold cut in reagent consumption with a 0.05 ng/mL of limit of detection (LOD) for IgA. The method was also applied to saliva samples obtained from healthy volunteers. The results correlated well to those obtained by the 96-well plate method. The method has the potential for use in disease diagnostic or on-site immunoassays. PMID:24859022

  1. Development, evaluation, and laboratory validation of immunoassays for the diagnosis of equine infectious anemia (EIA) using recombinant protein produced from a synthetic p26 gene of EIA virus.

    PubMed

    Singha, Harisankar; Goyal, Sachin K; Malik, Praveen; Khurana, Sandip K; Singh, Raj K

    2013-12-01

    Equine infectious anemia (EIA)-a retroviral disease caused by equine infectious anemia virus (EIAV)-is a chronic, debilitating disease of horses, mules, and donkeys. EIAV infection has been reported worldwide and is recognized as pathogen of significant economic importance to the horse industry. This disease falls under regulatory control program in many countries including India. Control of EIA is based on identification of inapparent carriers by detection of antibodies to EIAV in serologic tests and "Stamping Out" policy. The current internationally accepted test for diagnosis of EIA is the agar gel immune-diffusion test (AGID), which detects antibodies to the major gag gene (p26) product. The objective of this study was to develop recombinant p26 based in-house immunoassays [enzyme linked immunosorbent assays (ELISA), and AGID] for EIA diagnosis. The synthetic p26 gene of EIAV was expressed in Escherichia coli and diagnostic potential of recombinant p26 protein were evaluated in ELISA and AGID on 7,150 and 1,200 equine serum samples, respectively, and compared with commercial standard AGID kit. The relative sensitivity and specificity of the newly developed ELISA were 100 and 98.6 %, respectively. Whereas, relative sensitivity and specificity of the newly developed AGID were in complete agreement in respect to commercial AGID kit. Here, we have reported the validation of an ELISA and AGID on large number of equine serum samples using recombinant p26 protein produced from synthetic gene which does not require handling of pathogenic EIAV. Since the indigenously developed reagents would be economical than commercial diagnostic kit, the rp26 based-immunoassays could be adopted for the sero-diagnosis and control of EIA in India.

  2. Clinical Characteristics and Outcomes of Hematologic Malignancy Patients With Positive Clostridium difficile Toxin Immunoassay Versus Polymerase Chain Reaction Test Results.

    PubMed

    Ziegler, Matthew; Landsburg, Daniel; Pegues, David; Alby, Kevin; Gilmar, Cheryl; Bink, Kristen; Gorman, Theresa; Moore, Amy; Bonhomme, Brittaney; Omorogbe, Jacqueline; Tango, Dana; Tolomeo, Pam; Han, Jennifer H

    2018-04-25

    In a cohort of inpatients with hematologic malignancy and positive enzyme immunoassay (EIA) or polymerase chain reaction (PCR) Clostridium difficile tests, we found that clinical characteristics and outcomes were similar between these groups. The method of testing is unlikely to predict infection in this population, and PCR-positive results should be treated with concern.Infect Control Hosp Epidemiol 2018;1-4.

  3. Stool C difficile toxin

    MedlinePlus

    ... toxin; Colitis - toxin; Pseudomembranous - toxin; Necrotizing colitis - toxin; C difficile - toxin ... be analyzed. There are several ways to detect C difficile toxin in the stool sample. Enzyme immunoassay ( ...

  4. [DIAGNOSTIC VALUE OF COMBINED USE OF COMBINED METHOD OF ENZYME IMMUNOASSAY AND POLYMERASE CHAIN REACTION TO DETECT OF INTRAUTERINE FETAL INFECTION BY PARVOVIRUS B19].

    PubMed

    Bondarenko, N P; Lakatosh, V P; Lakatosh, P V; Malanchuk, O B; Poladich, I V

    2015-01-01

    The combined method of diagnosis parvovirus infection during pregnancy by maternal serum enzyme immunoassay and deoxyribonucleic acid isolation parvovirus B19 polymerase chain reaction in amnniotic fluid and fetal cord blood newborns, can diagnose vertical transmission and anticipate a negative effect on the fetus parvovirus. Lack of maternal IgM antibodies in serum due to parvovirus seroconversion during pregnancy does not exclude the persistence of the virus in the fetus. To analyze the diagnostic value of the method for determining the LHP parvovirus B19 DNA in the amniotic fluid, umbilical cord blood of newborns to determine vertical transmission of parvovirus infection when infected mothers B19 during pregnancy.

  5. Capillary electrophoresis-based immunoassays: principles and quantitative applications.

    PubMed

    Moser, Annette C; Hage, David S

    2008-08-01

    The use of CE as a tool to conduct immunoassays has been an area of increasing interest over the last decade. This approach combines the efficiency, small sample requirements, and relatively high speed of CE with the selectivity of antibodies as binding agents. This review examines the various assay formats and detection modes that have been reported for these assays, along with some representative applications. Most CE immunoassays in the past have employed homogeneous methods in which the sample and reagents are allowed to react in solution. These homogeneous methods have been conducted as both competitive binding immunoassays and as noncompetitive binding immunoassays. Fluorescent labels are most commonly used for detection in these assays, but enzyme labels have also been utilized for such work. Some additional work has been performed in CE immunoassays with heterogeneous methods in which either antibodies or an analog of the analyte is immobilized to a solid support. These heterogeneous methods can be used for the selective isolation of analytes prior to their separation by CE or to remove a given species from a sample/reagent mixture prior to analysis by CE. These CE immunoassays can be used with a variety of detection modes, such as fluorescence, UV/Vis absorbance, chemiluminescence, electrochemical measurements, MS, and surface plasmon resonance.

  6. Plasma exchange to remove HIT antibodies: dissociation between enzyme-immunoassay and platelet activation test reactivities.

    PubMed

    Warkentin, Theodore E; Sheppard, Jo-Ann I; Chu, F Victor; Kapoor, Anil; Crowther, Mark A; Gangji, Azim

    2015-01-01

    Repeated therapeutic plasma exchange (TPE) has been advocated to remove heparin-induced thrombocytopenia (HIT) IgG antibodies before cardiac/vascular surgery in patients who have serologically-confirmed acute or subacute HIT; for this situation, a negative platelet activation assay (eg, platelet serotonin-release assay [SRA]) has been recommended as the target serological end point to permit safe surgery. We compared reactivities in the SRA and an anti-PF4/heparin IgG-specific enzyme immunoassay (EIA), testing serial serum samples in a patient with recent (subacute) HIT who underwent serial TPE precardiac surgery, as well as for 15 other serially-diluted HIT sera. We observed that post-TPE/diluted HIT sera-when first testing SRA-negative-continue to test strongly positive by EIA-IgG. This dissociation between the platelet activation assay and a PF4-dependent immunoassay for HIT antibodies indicates that patients with subacute HIT undergoing repeated TPE before heparin reexposure should be tested by serial platelet activation assays even when their EIAs remain strongly positive. © 2015 by The American Society of Hematology.

  7. Field validation of recombinant antigen immunoassays for diagnosis of Lassa fever.

    PubMed

    Boisen, Matthew L; Hartnett, Jessica N; Shaffer, Jeffrey G; Goba, Augustine; Momoh, Mambu; Sandi, John Demby; Fullah, Mohamed; Nelson, Diana K S; Bush, Duane J; Rowland, Megan M; Heinrich, Megan L; Koval, Anatoliy P; Cross, Robert W; Barnes, Kayla G; Lachenauer, Anna E; Lin, Aaron E; Nekoui, Mahan; Kotliar, Dylan; Winnicki, Sarah M; Siddle, Katherine J; Gbakie, Michael; Fonnie, Mbalu; Koroma, Veronica J; Kanneh, Lansana; Kulakosky, Peter C; Hastie, Kathryn M; Wilson, Russell B; Andersen, Kristian G; Folarin, Onikepe O; Happi, Christian T; Sabeti, Pardis C; Geisbert, Thomas W; Saphire, Erica Ollmann; Khan, S Humarr; Grant, Donald S; Schieffelin, John S; Branco, Luis M; Garry, Robert F

    2018-04-12

    Lassa fever, a hemorrhagic fever caused by Lassa virus (LASV), is endemic in West Africa. It is difficult to distinguish febrile illnesses that are common in West Africa from Lassa fever based solely on a patient's clinical presentation. The field performance of recombinant antigen-based Lassa fever immunoassays was compared to that of quantitative polymerase chain assays (qPCRs) using samples from subjects meeting the case definition of Lassa fever presenting to Kenema Government Hospital in Sierra Leone. The recombinant Lassa virus (ReLASV) enzyme-linked immunosorbant assay (ELISA) for detection of viral antigen in blood performed with 95% sensitivity and 97% specificity using a diagnostic standard that combined results of the immunoassays and qPCR. The ReLASV rapid diagnostic test (RDT), a lateral flow immunoassay based on paired monoclonal antibodies to the Josiah strain of LASV (lineage IV), performed with 90% sensitivity and 100% specificity. ReLASV immunoassays performed better than the most robust qPCR currently available, which had 82% sensitivity and 95% specificity. The performance characteristics of recombinant antigen-based Lassa virus immunoassays indicate that they can aid in the diagnosis of LASV Infection and inform the clinical management of Lassa fever patients.

  8. Highly broad-specific and sensitive enzyme-linked immunosorbent assay for screening sulfonamides: Assay optimization and application to milk samples

    USDA-ARS?s Scientific Manuscript database

    A broad-specific and sensitive immunoassay for the detection of sulfonamides was developed by optimizing the conditions of an enzyme-linked immunosorbent assay (ELISA) in regard to different monoclonal antibodies (MAbs), assay format, immunoreagents, and several physicochemical factors (pH, salt, de...

  9. Enzyme immunoassays for detection of gypsy moth nuclear polyhedrosis virus

    Treesearch

    Michael Ma

    1985-01-01

    Enzyme-linked immunosorbent assays (ELISA) were developed for detecting gypsy moth (Lymantria dispar L.) nuclear polyhedrosis virus (NPV). They were used to detect the presence of NPV in hemoplymph samples collected from infected larvae. The incorporation of hybridoma antibodies with these procedures would make them even more specific for gypsy moth...

  10. Novel fluorescent probe for highly sensitive bioassay using sequential enzyme-linked immunosorbent assay-capillary isoelectric focusing (ELISA-cIEF).

    PubMed

    Henares, Terence G; Uenoyama, Yuta; Nogawa, Yuto; Ikegami, Ken; Citterio, Daniel; Suzuki, Koji; Funano, Shun-ichi; Sueyoshi, Kenji; Endo, Tatsuro; Hisamoto, Hideaki

    2013-06-07

    This paper presents a novel rhodamine diphosphate molecule that allows highly sensitive detection of proteins by employing sequential enzyme-linked immunosorbent assay and capillary isoelectric focusing (ELISA-cIEF). Seven-fold improvement in the immunoassay sensitivity and a 1-2 order of magnitude lower detection limit has been demonstrated by taking advantage of the combination of the enzyme-based signal amplification of ELISA and the concentration of enzyme reaction products by cIEF.

  11. Nanobody medicated immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein.

    PubMed

    Chen, Jing; He, Qing-hua; Xu, Yang; Fu, Jin-heng; Li, Yan-ping; Tu, Zhui; Wang, Dan; Shu, Mei; Qiu, Yu-lou; Yang, Hong-wei; Liu, Yuan-yuan

    2016-01-15

    Immunoassay for cancer biomarkers plays an important role in cancer prevention and early diagnosis. To the development of immunoassay, the quality and stability of applied antibody is one of the key points to obtain reliability and high sensitivity for immunoassay. The main purpose of this study was to develop a novel immunoassay for ultrasensitive detection of cancer biomarker alpha-fetoprotein (AFP) based on nanobody against AFP. Two nanobodies which bind to AFP were selected from a phage display nanobody library by biopanning strategy. The prepared nanobodies are clonable, thermally stable and applied in both sandwich enzyme linked immunoassay (ELISA) and immuno-PCR assay for ultrasensitive detection of AFP. The limit detection of sandwich ELISA setup with optimized nanobodies was 0.48ng mL(-1), and the half of saturation concentration (SC50) value was 6.68±0.56ng mL(-1). These nanobodies were also used to develop an immuno-PCR assay for ultrasensitive detection of AFP, its limit detection values was 0.005ng mL(-1), and the linear range was 0.01-10,000ng mL(-1). These established immunoassays based on nanobodies were highly specific to AFP and with negligible cross reactivity with other tested caner biomarkers. Furthermore, this novel concept of nanobodies mediated immunoassay may provide potential applications in a general method for the ultrasensitive detection of various cancer biomarkers. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. [Effects of low-intensity infrared impulse laser therapy on inflammation activity markers in patients with rheumatoid arthritis].

    PubMed

    Ilich-Stoianovich, O; Nasonov, E L; Balabanova, R M

    2000-01-01

    To evaluate effects of low-intensity infrared impulse laser therapy (IRILT) on concentration of immunity activation [not readable: see text] (soluble receptors of TNF-alpha and neopterin) and indicator of the inflammation activity (concentration of C-reactive protein) in patients with rheumatoid arthritis (RA). Enzyme immunoassay, radioimmunoassay, enzyme immunoassay and radial immunodiffusion were used to measure soluble receptors of TNF-alpha, neopterin and C-reactive protein in 38 females with verified RA receiving IRILT or sham procedures. IRILT induced lowering of neopterin, TNF-alpha soluble receptors (p < 0.01) and C-reactive protein (p < 0.01). The findings give pathogenetical grounds for IRILT use in RA as this treatment suppresses functional activity of macrophages which serve the main source of neopterin and the receptors synthesis.

  13. Determination of blood sirolimus concentrations in liver and kidney transplant recipients using the Innofluor® fluorescence polarization immunoassay: Comparison with the microparticle enzyme immunoassay and high-performance liquid chromatography-ultraviolet method

    PubMed Central

    Bouzas, Lorena; Hermida, Jesús

    2009-01-01

    Background Although high-performance liquid chromatography (HPLC) is the method of choice for blood sirolimus determination, the microparticle enzyme immunoassay (MEIA) run on the IMx® analyser is widely used in therapeutic monitoring of this immunosuppressant agent. The aim of our study was to evaluate the possible determination of sirolimus using the fluorescence polarization immunoassay (FPIA) commercialized for everolimus quantification. Methods Sirolimus concentrations were determined in whole-blood samples from liver and kidney transplant recipients using the Innofluor® Certican® FPIA (Seradyn Inc.) run on a TDx® analyser (Abbott Laboratories), Sirolimus MEIA run on an IMx® analyser (Abbott Laboratories), and HPLC (UV detection) methods. Results The Innofluor® FPIA has a similar cross-reactivity with everolimus and sirolimus, and the within- and between-run coefficients of variation obtained for sirolimus determination were 2.7%–13.3%. In analysing different blood samples from liver and kidney transplant patients the linear regressions obtained were: FPIA = 1.12 HPLC + 0.43 (n=104, r=0.874), MEIA = 1.14 HPLC (n=146, r=0.892), and FPIA = 1.00 MEIA + 0.29 (n=106, r=0.941). Better correlation coefficients were obtained between the methods in the liver transplant samples (r≥0.900) than in the kidney transplant samples (r≥0.849). No significant effect was found for sirolimus clearance or the blood hematocrit on the relationship between the results produced by both immunoassays and HPLC. Conclusion The Innofluor® FPIA is a valid alternative with an analogous performance to the MEIA for the therapeutic monitoring of sirolimus. PMID:19242874

  14. Enzyme immunoassay of two nicergoline metabolites, 10 alpha-methoxy-9, 10-dihydrolysergol (MDL) and 1-methyl-10 alpha-methoxy-9, 10-dihydrolysergol (MMDL).

    PubMed

    Chen, P; Tian, Z; Digenis, G A; Tai, H H

    1996-06-01

    Specific and sensitive enzyme immunoassays for two nicergoline metabolites, 10 alpha-methoxy-9, 10-dihydrolysergol (MDL) and 1-methyl-10 alpha-methoxy-9, 10-dihydrolysergol (MMDL) have been developed. The hydroxyl group of hydroxymethyl at position 8 of either MDL or MMDL was carboxymethylated to introduce a carboxyl group for protein conjugation. Antibodies generated from O-carboxymethyl MDL or MMDL recognized the spacer arm between the hapten and the carrier protein and the molecular domain near the conjugation site as well. A heterologous bridge strategy was used to improve the affinity of the hapten-enzyme conjugate to the antibodies. The sensitivity of both assays was greatly increased by using such an approach. Both antibodies are specific for their own haptens. Little cross reactivity was observed with nicergoline and other metabolites. Determination of MDL and MMDL from both spiked plasma and urine showed nearly quantitative recovery. Detection of MDL and MMDL can be as sensitive as 10 pg/ml.

  15. Development of immunoassays for human urokinase

    NASA Technical Reports Server (NTRS)

    Atassi, M. Zouhair

    1988-01-01

    Radioimmune assays (RIA) and enzyme linked immune assays for measurement of pro-urokinase and the two active forms of the enzyme were developed. Polyclonal and monoclonal antibodies, with desired specificities against preselected synthetic regions of urokinase (UK), were obtained by immunization with the respective synthetic peptides and used to develop RIA for zymogen and the two activated forms of UK.

  16. Amplification of the antigen-antibody interaction from quartz crystal microbalance immunosensors via back-filling immobilization of nanogold on biorecognition surface.

    PubMed

    Tang, Dian-Quan; Zhang, Da-Jun; Tang, Dian-Yong; Ai, Hua

    2006-10-20

    A new quartz crystal microbalance immunoassay method based on a novel transparent immunoaffinity reactor was developed for clinical immunoassay. To construct such an affinity reactor, resonators with a frequency of 10 MHz were fabricated by affinity binding of functionalized gold nanoparticles (nanogold) to quartz crystal with immobilized specific ligand for the label-free analysis of the affinity reaction between a ligand and its receptor. [Recombinant human tumor markers, carcinoembryonic antigen (CEA) was chosen as a model ligand.] The binding of target molecules onto the immobilized antibodies decreased the sensor's resonant frequency, and the frequency shift was proportional to the CEA concentration in the range of 3.0-50 ng/ml with a detection limit of 1.5 ng/ml at a signal/noise ration of 3. A glycine-HCl solution (pH 2.3) was used to release antigen-antibody complexes from the biorecognition surface. Good reusability was exhibited. Moreover, spiking various levels of CEA into normal human sera was diagnosed using the proposed immunoassay. Analytical results show the precision of the developed immunoassay is acceptable, implying a promising alternative approach for detecting CEA in clinical immunoassay. Compared with the conventional enzyme-linked immunosorbent assay, the proposed immunoassay system was simple and rapid without multiple labeling and separation steps. Importantly, the proposed immunoassay system could be further developed for the immobilization of other antigens or biocompounds.

  17. Laboratory diagnosis of viral infections

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lennette, E.H.

    1985-01-01

    This book contains 30 chapters. Some of the chapter titles are: Radioimmunoassay Systems; Enzyme Immunoassay Systems; Concepts of Clinical Diagnostic Virology; Role of Tissue Culture Systems, Adenoviruses; Influenza Viruses; Rabies Virus; and Rubella.

  18. Concentration Gradient Immunoassay I. A Rapid Immunoassay Based on Interdiffusion and Surface Binding in a Microchannel

    PubMed Central

    Nelson, Kjell E.; Foley, Jennifer O.; Yager, Paul

    2008-01-01

    We describe a novel microfluidic immunoassay method based on the diffusion of a small molecule analyte into a parallel-flowing stream containing cognate antibody. This interdiffusion results in a steady-state gradient of antibody binding site occupancy transverse to convective flow. In contrast to the diffusion immunoassay (Hatch et al. Nature Biotechnology,19:461−465 (2001)), this antibody occupancy gradient is interrogated by a sensor surface coated with a functional analog of the analyte. Antibodies with at least one unoccupied binding site may specifically bind to this functionalized surface, leading to a quantifiable change in surface coverage by the antibody. SPR imaging is used to probe the spatial distribution of antibody binding to the surface and, therefore, the outcome of the assay. We show that the pattern of antibody binding to the SPR sensing surface correlates with the concentration of a model analyte (phenytoin) in the sample stream. Using an inexpensive disposable microfluidic device, we demonstrate assays for phenytoin ranging in concentration from 75 to 1000 nM in phosphate buffer. At a total volumetric flow rate of 90 nL/sec, the assays are complete within 10 minutes. Inclusion of an additional flow stream on the side of the antibody stream opposite to that of the sample enables simultaneous calibration of the assay. This assay method is suitable for rapid quantitative detection of low-molecular weight analytes for point-of-care diagnostic instrumentation. PMID:17437332

  19. Magnetic bead-based enzyme-chromogenic substrate system for ultrasensitive colorimetric immunoassay accompanying cascade reaction for enzymatic formation of squaric acid-iron(III) chelate.

    PubMed

    Lai, Wenqiang; Tang, Dianping; Zhuang, Junyang; Chen, Guonan; Yang, Huanghao

    2014-05-20

    This work reports on a simple and feasible colorimetric immunoassay with signal amplification for sensitive determination of prostate-specific antigen (PSA, used as a model) at an ultralow concentration by using a new enzyme-chromogenic substrate system. We discovered that glucose oxidase (GOx), the enzyme broadly used in enzyme-linked immunosorbent assay (ELISA), has the ability to stimulate in situ formation of squaric acid (SQA)-iron(III) chelate. GOx-catalyzed oxidization of glucose leads to the formation of gluconic acid and hydrogen peroxide (H2O2). The latter can catalytically oxidize iron(II) to iron(III), which can rapidly (<1 min) coordinate with the SQA. Formation of the iron-squarate complex causes the color of the solution to change from bluish purple to bluish red accompanying the increasing absorbance with the increment of iron(III) concentration. On the basis of the SQA-iron(III) system, a new immunoassay protocol with GOx-labeled anti-PSA detection antibody can be designed for the detection of target PSA on capture antibody-functionalized magnetic immunosensing probe, monitored by recording the color or absorbance (λ = 468 nm) of the generated SQA-iron(III) chelate. The absorbance intensity shows to be dependent on the concentration of target PSA. A linear dependence between the absorbance and target PSA concentration is obtained under optimal conditions in the range from 1.0 pg mL(-1) to 30 ng mL(-1) with a detection limit (LOD) of 0.5 pg mL(-1) (0.5 ppt) estimated at the 3Sblank level. The sensitivity displays to be 3-5 orders of magnitude better than those of most commercialized human PSA ELISA kits. In addition, the developed colorimetric immunoassay was validated by assaying 12 human serum samples, receiving in good accordance with those obtained by the commercialized PSA ELISA kit. Importantly, the SQA-based immunosensing system can be further extended for the detection of other low-abundance proteins or biomarkers by controlling the target antibody.

  20. Reproducibility of risk figures in 2nd-trimester maternal serum screening for down syndrome: comparison of 2 laboratories.

    PubMed

    Benn, Peter A; Makowski, Gregory S; Egan, James F X; Wright, Dave

    2006-11-01

    Analytical error affects 2nd-trimester maternal serum screening for Down syndrome risk estimation. We analyzed the between-laboratory reproducibility of risk estimates from 2 laboratories. Laboratory 1 used Bayer ACS180 immunoassays for alpha-fetoprotein (AFP) and human chorionic gonadotropin (hCG), Diagnostic Systems Laboratories (DSL) RIA for unconjugated estriol (uE3), and DSL enzyme immunoassay for inhibin-A (INH-A). Laboratory 2 used Beckman immunoassays for AFP, hCG, and uE3, and DSL enzyme immunoassay for INH-A. Analyte medians were separately established for each laboratory. We used the same computational algorithm for all risk calculations, and we used Monte Carlo methods for computer modeling. For 462 samples tested, risk figures from the 2 laboratories differed >2-fold for 44.7%, >5-fold for 7.1%, and >10-fold for 1.7%. Between-laboratory differences in analytes were greatest for uE3 and INH-A. The screen-positive rates were 9.3% for laboratory 1 and 11.5% for laboratory 2, with a significant difference in the patients identified as screen-positive vs screen-negative (McNemar test, P<0.001). Computer modeling confirmed the large between-laboratory risk differences. Differences in performance of assays and laboratory procedures can have a large effect on patient-specific risks. Screening laboratories should minimize test imprecision and ensure that each assay performs in a manner similar to that assumed in the risk computational algorithm.

  1. Highly sensitive microfluidic competitive enzyme immunoassay based on chemiluminescence resonance energy transfer for the detection of neuron-specific enolase.

    PubMed

    Yang, Tingzhen; Vdovenko, Marina; Jin, Xue; Sakharov, Ivan Yu; Zhao, Shulin

    2014-07-01

    A microfluidic competitive enzyme immunoassay based on chemiluminescence resonance energy transfer (CRET) was developed for highly sensitive detection of neuron-specific enolase (NSE). The CRET system consisted of horseradish peroxidase (HRP)/luminol as a light donor and fluorescein isothiocyanate as an acceptor. When fluorescein isothiocyanate-labeled antibody binds with HRP-labeled antigen to form immunocomplex, the donor and acceptor are brought close each other and CRET occurs in the immunocomplex. In the MCE, the immunocomplex and excess HRP-NSE were separated, and the chemiluminescense intensity of immunocomplex was used to estimate NSE concentration. The calibration curve showed a linearity in the range of NSE concentrations from 9.0 to 950 pM with a correlation coefficient of 0.9964. Based on a S/N of 3, the detection limit for NSE determination was estimated to be 4.5 pM, which is two-order magnitude lower than that of without CRET detection. This assay was applied for NSE quantification in human serum. The obtained results demonstrated that the proposed immunoassay may serve as an alternative tool for clinical analysis of NSE. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  2. Preparation of a Magnetically Switchable Bioelectrocatalytic System Employing Cross-Linked Enzyme Aggregates in Magnetic Mesocellular Carbon Foam

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, Jinwoo; Lee, Dohun; Oh, Eunkeu

    2005-11-18

    Nanostructured magnetic materials (NMMs)[1] have attracted much attention recently because of their broad biotechnological applications including support matrices for enzyme immobilization,[2] immunoassays,[3] drug delivery,[4] and biosensors.[ 5] Specifically, the easy separation and controlled placement of NMMs by means of an external magnetic field enables their application in the development of immobilized enzyme processes[2] and the construction of magnetically controllable bio-electrocatalytic systems.[5, 6] Herein, we demonstrate the use of immobilized enzymes in NMMs for magnetically switchable bio-electrocatalysis.

  3. Novel immunoassay formats for integrated microfluidic circuits: diffusion immunoassays (DIA)

    NASA Astrophysics Data System (ADS)

    Weigl, Bernhard H.; Hatch, Anson; Kamholz, Andrew E.; Yager, Paul

    2000-03-01

    Novel designs of integrated fluidic microchips allow separations, chemical reactions, and calibration-free analytical measurements to be performed directly in very small quantities of complex samples such as whole blood and contaminated environmental samples. This technology lends itself to applications such as clinical diagnostics, including tumor marker screening, and environmental sensing in remote locations. Lab-on-a-Chip based systems offer many *advantages over traditional analytical devices: They consume extremely low volumes of both samples and reagents. Each chip is inexpensive and small. The sampling-to-result time is extremely short. They perform all analytical functions, including sampling, sample pretreatment, separation, dilution, and mixing steps, chemical reactions, and detection in an integrated microfluidic circuit. Lab-on-a-Chip systems enable the design of small, portable, rugged, low-cost, easy to use, yet extremely versatile and capable diagnostic instruments. In addition, fluids flowing in microchannels exhibit unique characteristics ('microfluidics'), which allow the design of analytical devices and assay formats that would not function on a macroscale. Existing Lab-on-a-chip technologies work very well for highly predictable and homogeneous samples common in genetic testing and drug discovery processes. One of the biggest challenges for current Labs-on-a-chip, however, is to perform analysis in the presence of the complexity and heterogeneity of actual samples such as whole blood or contaminated environmental samples. Micronics has developed a variety of Lab-on-a-Chip assays that can overcome those shortcomings. We will now present various types of novel Lab- on-a-Chip-based immunoassays, including the so-called Diffusion Immunoassays (DIA) that are based on the competitive laminar diffusion of analyte molecules and tracer molecules into a region of the chip containing antibodies that target the analyte molecules. Advantages of this technique are a reduction in reagents, higher sensitivity, minimal preparation of complex samples such as blood, real-time calibration, and extremely rapid analysis.

  4. Development of a highly sensitive chemiluminescence enzyme immunoassay using enhanced luminol as substrate.

    PubMed

    Tao, Xiaoqi; Wang, Wenjun; Wang, Zhanhui; Cao, Xingyuan; Zhu, Jinghui; Niu, Lanlan; Wu, Xiaoping; Jiang, Haiyang; Shen, Jianzhong

    2014-06-01

    In this study, a high sensitivity chemiluminescence enzyme immunoassay (CLEIA) based on novel enhancers was developed. Under optimal conditions, we developed an enhanced chemiluminescence reaction (ECR) catalyzed by horseradish peroxidase (HRP-C) in the presence of 3-(10'-phenothiazinyl) propane-1-sulfonate (SPTZ) and 4-morpholinopyridine (MORP) as enhancers. The limit of detection of the newly prepared chemiluminescent cocktail for HRP was 0.33 pg/well, which is lower than that of commercial Super Signal substrate. The results showed that this novel chemiluminescent cocktail can significantly increase the light output of HRP-catalyzed ECR, which can be translated into a corresponding improvement in sensitivity. Similar improvements were observed in CLEIA for the determination of chloramphenicol in milk. In addition, the ECR of N-azoles as secondary enhancer was also presented. Copyright © 2013 John Wiley & Sons, Ltd.

  5. Evaluation of three commercial rapid tests for detecting antibodies to human immunodeficiency virus.

    PubMed

    Ng, K P; Saw, T L; Baki, A; Kamarudin, R

    2003-08-01

    Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest are simple/rapid tests for the detection of antibodies to HIV-1 and HIV-2 in human whole blood, serum and plasma samples. The assay is one step and the result is read visually within 15 minutes. Using 92 known HIV-1 reactive sera and 108 known HIV-1 negative sera, the 3 HIV tests correctly identified all the known HIV-1 reactive and negative samples. The results indicated that Determine HIV-1/2, Chembio HIV-1/2 STAT-PAK and PenTest HIV are as sensitive and specific (100% concordance) as Microparticle Enzyme Immunoassay. The data indicated that these 3 HIV tests are effective testing systems for diagnosis of HIV infection in a situation when the conventional Enzyme Immunoassay is not suitable.

  6. Chemiluminescence enzyme immunoassay for the determination of sulfamethoxydiazine

    NASA Astrophysics Data System (ADS)

    Wu, Yongjun; Yu, Songcheng; Yu, Fei; Yan, Nali; Qu, Lingbo; Zhang, Hongquan

    2011-10-01

    Sulfamethoxydiazine (SMD), which is often used for animal disease treatment, is harmful to human health. No SMD residue should be detected in food in some countries, such as USA and Japan. Therefore, it is significant to develop a high-throughput, high-sensitivity and accurate method for the determination of the content of SMD in food. In this paper, chemiluminescence enzyme immunoassay (CLEIA) was developed for quantification of SMD. For this method, the limit of detection was 3.2 pg/ml, the linear range was from 10 to 2000 pg/ml, the within-day and inter-day precision were below 13% and below 18%, respectively, and the recovery was from 85% to 105%. Milk and egg were selected as samples to be examined with this method, and the result indicated that this CLEIA method was suitable for screening and quality control of food.

  7. A highly specific competitive direct enzyme immunoassay for sterigmatocystin as a tool for rapid immunochemotaxonomic differentiation of mycotoxigenic Aspergillus species.

    PubMed

    Wegner, S; Bauer, J I; Dietrich, R; Märtlbauer, E; Usleber, E; Gottschalk, C; Gross, M

    2017-02-01

    A simplified method to produce specific polyclonal rabbit antibodies against sterigmatocystin (STC) was established, using a STC-glycolic acid-ether derivative (STC-GE) conjugated to keyhole limpet haemocyanin (immunogen). The competitive direct enzyme immunoassay (EIA) established for STC had a detection limit (20% binding inhibition) of 130 pg ml -1 . The test was highly specific for STC, with minor cross-reactivity with O-methylsterigmatocystin (OMSTC, 0·87%) and negligible reactivity with aflatoxins (<0·02%). STC-EIA was used in combination with a previously developed specific EIA for aflatoxins (<0·1% cross-reactivity with STC and OMSTC), to study the STC/aflatoxin production profiles of reference strains of Aspergillus species. This immunochemotaxonomic procedure was found to be a convenient tool to identify STC- or aflatoxin-producing strains. The carcinogenic mycotoxin sterigmatocystin (STC) is produced by several Aspergillus species, either alone or together with aflatoxins. Here, we report a very simple and straightforward procedure to obtain highly sensitive and specific anti-STC antibodies, and their use in the first ever real STC-specific competitive direct enzyme immunoassay (EIA). In combination with a previous EIA for aflatoxins, this study for the first time demonstrates the potential of a STC/aflatoxin EIA pair for what is branded as 'immunochemotaxonomic' identification of mycotoxigenic Aspergillus species. This new analytical tool enhances analytical possibilities for differential analysis of STC and aflatoxins. © 2016 The Society for Applied Microbiology.

  8. Impact of HIV Subtype on Performance of the Limiting Antigen-Avidity Enzyme Immunoassay, the Bio-Rad Avidity Assay, and the BED Capture Immunoassay in Rakai, Uganda

    PubMed Central

    Longosz, Andrew F.; Serwadda, David; Nalugoda, Fred; Kigozi, Godfrey; Franco, Veronica; Gray, Ronald H.; Quinn, Thomas C.; Eshleman, Susan H.

    2014-01-01

    Abstract Previous studies demonstrated that individuals with subtype D HIV infection who had been infected for 2 or more years were frequently misclassified as assay positive using cross-sectional incidence assays. Samples from 510 subjects (212 subtype A, 298 subtype D) who were infected for 2.2 to 14.5 years (median 5.4 years) and were not virally suppressed were tested using an LAg-Avidity enzyme immunoassay (LAg-Avidity EIA), Bio-Rad Avidity assay, and BED capture enzyme immunoassay (BED-CEIA). The performance of these three assays was evaluated using various assay cutoff values [LAg-Avidity EIA: <1.0 OD-n and <2.0 OD-n; Bio-Rad Avidity assay: <40% avidity index (AI) and <80% AI; BED-CEIA: <0.8 OD-n]. The mean LAg-Avidity EIA result was higher for subtype A than D (4.54±0.95 vs. 3.86±1.26, p<0.001); the mean Bio-Rad Avidity assay result was higher for subtype A than D (88.9%±12.5% vs. 75.1±30.5, p<0.001); and the mean BED-CEIA result was similar for the two subtypes (2.2±1.2 OD-n for subtype A, 2.2±1.3 OD-n for subtype D, p<0.9). The frequency of misclassification was higher for individuals with subtype D infection compared to those with subtype A infection, using either the LAg-Avidity EIA with a cutoff of <2.0 OD-n or the Bio-Rad Avidity assay with cutoffs of <40% or <80% AI. No subtype-specific differences in assay performance were observed using the BED-CEIA. Sex and age were not significantly associated with misclassification by any assay. The LAg-Avidity EIA with a cutoff <1.0 OD-n had the lowest frequency of misclassification in this Ugandan population. PMID:24083837

  9. Surface plasmon resonance biosensing: Approaches for screening and characterising antibodies for food diagnostics.

    PubMed

    Yakes, B J; Buijs, J; Elliott, C T; Campbell, K

    2016-08-15

    Research in biosensing approaches as alternative techniques for food diagnostics for the detection of chemical contaminants and foodborne pathogens has increased over the last twenty years. The key component of such tests is the biorecognition element whereby polyclonal or monoclonal antibodies still dominate the market. Traditionally the screening of sera or cell culture media for the selection of polyclonal or monoclonal candidate antibodies respectively has been performed by enzyme immunoassays. For niche toxin compounds, enzyme immunoassays can be expensive and/or prohibitive methodologies for antibody production due to limitations in toxin supply for conjugate production. Automated, self-regenerating, chip-based biosensors proven in food diagnostics may be utilised as rapid screening tools for antibody candidate selection. This work describes the use of both single channel and multi-channel surface plasmon resonance (SPR) biosensors for the selection and characterisation of antibodies, and their evaluation in shellfish tissue as standard techniques for the detection of domoic acid, as a model toxin compound. The key advantages in the use of these biosensor techniques for screening hybridomas in monoclonal antibody production were the real time observation of molecular interaction and rapid turnaround time in analysis compared to enzyme immunoassays. The multichannel prototype instrument was superior with 96 analyses completed in 2h compared to 12h for the single channel and over 24h for the ELISA immunoassay. Antibodies of high sensitivity, IC50's ranging from 4.8 to 6.9ng/mL for monoclonal and 2.3-6.0ng/mL for polyclonal, for the detection of domoic acid in a 1min analysis time were selected. Although there is a progression for biosensor technology towards low cost, multiplexed portable diagnostics for the food industry, there remains a place for laboratory-based SPR instrumentation for antibody development for food diagnostics as shown herein. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Analysis of drugs in human tissues by supercritical fluid extraction/immunoassay

    NASA Astrophysics Data System (ADS)

    Furton, Kenneth G.; Sabucedo, Alberta; Rein, Joseph; Hearn, W. L.

    1997-02-01

    A rapid, readily automated method has been developed for the quantitative analysis of phenobarbital from human liver tissues based on supercritical carbon dioxide extraction followed by fluorescence enzyme immunoassay. The method developed significantly reduces sample handling and utilizes the entire liver homogenate. The current method yields comparable recoveries and precision and does not require the use of an internal standard, although traditional GC/MS confirmation can still be performed on sample extracts. Additionally, the proposed method uses non-toxic, inexpensive carbon dioxide, thus eliminating the use of halogenated organic solvents.

  11. Refolding of autodisplayed anti-NEF scFv through oxidation with glutathione for immunosensors.

    PubMed

    Bong, Ji-Hong; Song, Hyun-Woo; Kim, Tae-Hun; Kang, Min-Jung; Jose, Joachim; Pyun, Jae-Chul

    2018-04-15

    In this study, a single-domain antibody against negative regulatory factor (anti-NEF scFv) was autodisplayed on the outer membrane of Escherichia coli and used to detect NEF in an immunoassay based on fluorescence-activated cell sorting, enzyme-linked immunosorbent assay, and surface plasmon resonance biosensors. Next, the autodisplayed single-domain antibody was oxidized to form disulfide bonds by using glutathione, and the change in NEF-binding activity of anti-NEF scFv was analyzed by fluorescence-activated cell sorting-based immunoassay, chromogenic immunoassay, and surface plasmon resonance biosensor. For each type of immunoassays the anti-NEF scFv on the isolated outer membrane showed more NEF binding activity after the disulfide bond formation by glutathione. To determine the role of cysteines in anti-NEF scFv, three mutants were prepared, and the NEF binding activity of mutants was compared with that of wild-type anti-NEF scFv in a competitive immunoassay based on FACS. In these mutant studies, the refolding process of autodisplayed anti-NEF scFv by following oxidation via GSH/GSSG revealed that disulfide bonds formed and increased NEF binding activity. Copyright © 2017 Elsevier B.V. All rights reserved.

  12. IMMUNOCHEMICAL DETERMINATION OF DIOXINS IN SEDIMENT SAMPLES

    EPA Science Inventory

    Polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) are considered highly toxic contaminants with the environmental monitoring of these compounds being of great importance. Immunoassay procedures such as the enzyme-linked immunosorbent assay (ELIS...

  13. ELEGANT ENVIRONMENTAL IMMUNOASSAYS

    EPA Science Inventory

    Immunochemical methods are based on selective antibodies directed to a particular target analyte. The specific binding between antibody and analyte can be used for detection and quantitation. Methods such as the enzyme-linked immunosorbent assay (ELISA) can provide a sensitiv...

  14. Hemostatic Function of Apheresis Platelets Stored at 4 deg C and 22 deg C

    DTIC Science & Technology

    2014-05-01

    utilized. Thromboxane B2 (TxB2) enzyme immunoassay kits were purchased from Cayman Chemicals (Ann Arbor, MI), and human soluble CD40L (sCD40L) extra...sensitive platinum enzyme linked immunosorbent assay kits were pur chased from eBioscience (Vienna, Austria). CG4+ and CHEM8+ cartridges were purchased from...TruCount tubes (BD Biosciences). Enzyme linked immunosorbent assay Commercially available kits were used to assess sCD40L and TxB2 levels released into

  15. Immunoassay as an analytical tool in agricultural biotechnology.

    PubMed

    Grothaus, G David; Bandla, Murali; Currier, Thomas; Giroux, Randal; Jenkins, G Ronald; Lipp, Markus; Shan, Guomin; Stave, James W; Pantella, Virginia

    2006-01-01

    Immunoassays for biotechnology engineered proteins are used by AgBiotech companies at numerous points in product development and by feed and food suppliers for compliance and contractual purposes. Although AgBiotech companies use the technology during product development and seed production, other stakeholders from the food and feed supply chains, such as commodity, food, and feed companies, as well as third-party diagnostic testing companies, also rely on immunoassays for a number of purposes. The primary use of immunoassays is to verify the presence or absence of genetically modified (GM) material in a product or to quantify the amount of GM material present in a product. This article describes the fundamental elements of GM analysis using immunoassays and especially its application to the testing of grains. The 2 most commonly used formats are lateral flow devices (LFD) and plate-based enzyme-linked immunosorbent assays (ELISA). The main applications of both formats are discussed in general, and the benefits and drawbacks are discussed in detail. The document highlights the many areas to which attention must be paid in order to produce reliable test results. These include sample preparation, method validation, choice of appropriate reference materials, and biological and instrumental sources of error. The article also discusses issues related to the analysis of different matrixes and the effects they may have on the accuracy of the immunoassays.

  16. PCP IMMUMOASSAY TECHNOLOGIES - INNOVATIVE TECHNOLOGY EVALUATION REPORT

    EPA Science Inventory

    Three enzyme-linked immunosorbent assay technologies for pentachlorophenol (PCP) testing in soil and water were evaluated. Penta RISc Test Systems (formerly ENSYS, Inc.), EnviroGard™ PCP Immunoassay Test Kit (Millipore Corp.), and Pentachlorophenol RaPID Assay (formerly Ohmicron ...

  17. [Possibility of the species identification using blood stains located on the material evidences and bone fragments with the method of solid phase enzyme immunoassay with "IgG general-EIA-BEST" kit and human immunoglobulin G].

    PubMed

    Sidorov, V L; Shvetsova, I V; Isakova, I V

    2007-01-01

    The authors give the comparative analysis of Russian and foreign forensic medical methods of species character identification of the blood from the stains on the material evidences and bone fragments. It is shown that for this purpose it is feasible to apply human immunoglobulin G (IgG) and solid phase enzyme immunoassay (EIA) with the kit "IgG general-EIA-BEST". In comparison with the methods used in Russia this method is more sensitive, convenient for objective registration and computer processing. The results of experiments shown that it is possible to use the kit "IgG general-EIA-BEST" in forensic medicine for the species character identification of the blood from the stains on the material evidences and bone fragments.

  18. A prospective field evaluation of an enzyme immunoassay: Detection of eastern equine encephalomyelitis virus antigen in pools of Culiseta melanura

    USGS Publications Warehouse

    Scott, T.W.; Olson, J.G.; Lewis, T.E.; Carpenter, J.W.; Lorenz, L.H.; Lembeck, L.A.; Joseph, S.R.; Pagac, B.B.

    1987-01-01

    A prospective field study was conducted to determine the sensitivity and specificity of an enzyme immunoassay (EIA) compared to virus isolation in cell culture for the detection of eastern equine encephalomyelitis (EEE) virus in naturally infected mosquitoes. A total of 10,811 adult female Culiseta melanura were collected in light traps during 1985 from four locations in Maryland. Eastern equine encephalomyelitis virus was isolated from 5 of 495 mosquito pools in African green monkey kidney and baby hamster kidney cell cultures. All five virus-infected pools were detected by the EIA, and all 490 uninfected pools were correctly scored as not containing virus. The EIA did not produce false positive or false negative results. Results support the assertion of previous researchers that the antigen detection EIA is a rapid, sensitive, specific, and simple alternative to traditional bioassays for the detection of EEE virus in mosquitoes.

  19. Enzymatic amplification of a flow-injected thermometric enzyme-linked immunoassay for human insulin.

    PubMed

    Mecklenburg, M; Lindbladh, C; Li, H; Mosbach, K; Danielsson, B

    1993-08-01

    A flow-injected thermometric enzyme linked immunoassay for human insulin which employs the lactate dehydrogenase/lactate oxidase (LDH/LOD) substrate recycling system for signal amplification is described. The system is composed of two columns, an immunosorbent column containing immobilized anti-insulin antibodies for sensing and a recycling column containing immobilized LDH/LOD/Catalase for detection. The effect of flow rates, conjugate concentrations, and chromatographic support material upon the sensitivity of the assay are investigated. The assay has a detection limit of 0.025 microgram/ml and a linear range from 0.05 to 2 micrograms/ml. This corresponds to a 10-fold increase in sensitivity over the unamplified system. A recombinant human insulin-proinsulin conjugate was also tested. The results show that enzymatic amplification can be employed to increase the sensitivity and reproducibility of flow injection assay-based biosensors. The implications of these results upon on-line analysis are discussed.

  20. [Establishment of chemiluminescent enzyme immunoassay for detecting antibodies against foot-and-mouth disease virus serotype O in swine].

    PubMed

    Cui, Chen; Huang, Ligang; Li, Jing; Zou, Xingqi; Zhu, Yuanyuan; Xie, Lei; Zhao, Qizu; Yang, Limin; Liu, Wenjun

    2016-11-25

    Recombinant structural protein VP1 of foot-and-mouth disease virus serotype O was expressed in Escherichia coli and then purified using Nickel affinity chromatography. A chemiluminescent enzyme immunoassay (CLEIA) method was established using the purified recombinant protein as coating antigen to detect antibody of foot-and-mouth disease virus serotype O in swine. The specificity of VP1-CLEIA method is 100%. The coefficients of variation in the plate and between plates are 1.10%-6.70% and 0.66%-4.80%, respectively. Comparing with the commercial indirect ELISA kit or liquid phase block ELISA kit, the calculated coincidence rate is 93.50% or 94.00%. The high specificity and stability suggested this detection method can be used to monitor the antibody level of foot-and-mouth disease virus serotype O in swine.

  1. False Elevation of the Blood Tacrolimus Concentration, as Assessed by an Affinity Column-mediated Immunoassay (ACMIA), Led to Acute T Cell-mediated Rejection after Kidney Transplantation.

    PubMed

    Kono, Momoko; Hasegawa, Jumpei; Ogawa, Hina; Yoshikawa, Kanae; Ishiwatari, Ayumi; Wakai, Sachiko; Tanabe, Kazunari; Shirakawa, Hiroki

    2018-05-01

    Tacrolimus is the most commonly used immunosuppressant. Because of its narrow therapeutic range, it is necessary to frequently monitor its concentration. We report the case of a 25-year-old man who underwent kidney transplantation whose tacrolimus concentrations, as measured by an affinity column-mediated immunoassay, were falsely elevated. As we reduced the dose of tacrolimus, the recipient developed T cell-mediated rejection. Using the same blood samples, an enzyme-multiplied immunoassay technique showed that the patient's levels of tacrolimus were extremely low. A further examination indicated that the false increase in the tacrolimus concentration was likely due to an unknown interfering substance. We administered methylprednisolone and antithymocyte-globulin. The patient's serum creatinine level decreased and remained stable after these treatments.

  2. [Comparative sensitivity of different solid-phase immunoassays for detecting HBsAg and anti-HCV in blood].

    PubMed

    León, P; López, J A; Domingo, C J; Echevarría, J M

    1992-10-01

    The sensitivities of seven methods of enzyme-immunoassay for HBsAg detection, as well as of twelve immunoassays for detecting antibody to HCV, were compared, in an attempt to evaluate the need for an official technical validation of such methods prior to its commercialization in Spain. Significant differences were seen for the sensitivities of these methods, which may influence the proficiency of blood bank screening for HBsAg and anti-HCV for preventing cases of post-transfusional viral hepatitis. As a conclusion, it is recommended to establish legal regulations for pre-marketing validation of such assays in Spain, as well as to take the results obtained in these evaluation studies as the basis for selecting those tests which may be more convenient for screening purposes at the blood banks.

  3. Comparison of a neutralization enzyme immunoassay and an enzyme-linked immunosorbent assay for evaluation of immune status of children vaccinated for mumps.

    PubMed Central

    Harmsen, T; Jongerius, M C; van der Zwan, C W; Plantinga, A D; Kraaijeveld, C A; Berbers, G A

    1992-01-01

    A 50% neutralization enzyme immunoassay (N50-EIA) was compared with an indirect enzyme-linked immunosorbent assay (ELISA) for determining mumps virus antibodies in three consecutive serum samples from 138 children vaccinated with a live mumps vaccine at the age (in years) of 1.5. By the N50-EIA, most (132 of 138) preserum samples did not show neutralizing activity. Eight to 12 weeks after vaccination, 17 of the children were still negative, but only 7 remained so after 2.5 years, resulting in a seroconversion rate of 125 of 132 (95%). Over the same period, the neutralization geometric mean titer rose from 3.6 to 9.9. By an indirect ELISA, 128 of 138 preserum samples were found negative. The early and late postvaccination sera of 8 children were ELISA negative, resulting in a seroconversion rate of 120 of 128 (94%). Only two children remained seronegative by both methods. Seven of the late postvaccination serum samples yielded noncorresponding results, reflecting 95% correlation between both methods. Due to cross-reactivity with parainfluenza viruses, the ELISA proved to be less specific, but on the other hand, it showed a greater sensitivity than the N50-EIA. PMID:1500523

  4. Optical Sensors for Biomolecules Using Nanoporous Sol-Gel Materials

    NASA Technical Reports Server (NTRS)

    Fang, Jonathan; Zhou, Jing C.; Lan, Esther H.; Dunn, Bruce; Gillman, Patricia L.; Smith, Scott M.

    2004-01-01

    An important consideration for space missions to Mars is the ability to detect biosignatures. Solid-state sensing elements for optical detection of biological entities are possible using sol-gel based biologically active materials. We have used these materials as optical sensing elements in a variety of bioassays, including immunoassays and enzyme assays. By immobilizing an appropriate biomolecule in the sol-gel sensing element, we have successfully detected analytes such as amino acids and hormones. In the case of the amino acid glutamate, the enzyme glutamate dehydrogenase was the immobilized molecule, whereas in the case of the hormone cortisol, an anti-cortisol antibody was immobilized in the sensing element. In this previous work with immobilized enzymes and antibodies, excellent sensitivity and specificity were demonstrated in a variety of formats including bulk materials, thin films and fibers. We believe that the sol-gel approach is an attractive platform for bioastronautics sensing applications because of the ability to detect a wide range of entities such as amino acids, fatty acids, hopanes, porphyrins, etc. The sol-gel approach produces an optically transparent 3D silica matrix that forms around the biomolecule of interest, thus stabilizing its structure and functionality while allowing for optical detection. This encapsulation process protects the biomolecule and leads to a more "rugged" sensor. The nanoporous structure of the sol-gel matrix allows diffusion of small target molecules but keeps larger, biomolecules immobilized in the pores. We are currently developing these biologically active sol-gel materials into small portable devices for on-orbit cortisol detection

  5. Bupropion interference with immunoassays for amphetamines and LSD.

    PubMed

    Vidal, Christian; Skripuletz, Thomas

    2007-06-01

    A 50-year-old male patient suddenly had lost consciousness, although he had previously been healthy. On arrival at hospital seizures arose. The authors investigated a urine sample of the patient, and performed toxicological drug screening with immunochemical Cloned Enzyme Donor Immunoassay (CEDIA) assays. Positive findings for amphetamines and LSD could not be confirmed. Using gas chromatography/mass spectrometry (GC/MS), and liquid chromatography/mass spectrometry (LC/MS), the authors identified bupropion, a drug used to aid in smoking cessation, as the interfering compound, which may cause false-positive results for amphetamines and LSD using the CEDIA assays.

  6. Regulatory effect of Epithalon on production of melatonin and cortisol in old monkeys.

    PubMed

    Goncharova, N D; Khavinson, B K; Lapin, B A

    2001-04-01

    The effect of Epithalon on melatonin and cortisol secretion in female rhesus monkeys of various ages was evaluated by enzyme immunoassay. Epithalon stimulated evening melatonin production and normalized circadian rhythms of cortisol production in old monkeys.

  7. Stalking The Silent Killers.

    ERIC Educational Resources Information Center

    DeYoung, H. Garrett

    1983-01-01

    New technologies have been developed to diagnose such disorders as cancer, heart disease, and defects of the newborn in presymptomatic stages. Several technologies, including amniocentesis, radioimmunoassay, enzyme immunoassay, multichannel analysis and others are discussed. Development of these technologies and issues related to their use are…

  8. Effect of monensin on the levels of tachykinins and their processing enzyme activity in rat dorsal root ganglia.

    PubMed

    Chikuma, Toshiyuki; Inomata, Yuji; Tsuchida, Ken; Hojo, Hiroshi; Kato, Takeshi

    2002-06-28

    Th effect of monensin, which inhibits trans-Golgi function, on the levels of tachykinins and their processing enzyme activity was examined in organ-cultured rat dorsal root ganglia (DRG). Using an enzyme immunoassay method, we measured neurokinin A and substance P immunoreactivity in the DRG cultured for 72 h with and without 0.1 microM monensin. Both tachykinins were reduced in the DRG treated with monensin. Treatment with monensin also reduced the activity of carboxypeptidase E, which is one of the proteolytic processing enzymes of neuropeptides. These data suggest that proteolytic processing enzymes may in part modulate the biological activity of neuropeptides within a trans-Golgi apparatus.

  9. Immunoanalysis Methods for the Detection of Dioxins and Related Chemicals

    PubMed Central

    Tian, Wenjing; Xie, Heidi Qunhui; Fu, Hualing; Pei, Xinhui; Zhao, Bin

    2012-01-01

    With the development of biotechnology, approaches based on antibodies, such as enzyme-linked immunosorbent assay (ELISA), active aryl hydrocarbon immunoassay (Ah-I) and other multi-analyte immunoassays, have been utilized as alternatives to the conventional techniques based on gas chromatography and mass spectroscopy for the analysis of dioxin and dioxin-like compounds in environmental and biological samples. These screening methods have been verified as rapid, simple and cost-effective. This paper provides an overview on the development and application of antibody-based approaches, such as ELISA, Ah-I, and multi-analyte immunoassays, covering the sample extraction and cleanup, antigen design, antibody preparation and immunoanalysis. However, in order to meet the requirements for on-site fast detection and relative quantification of dioxins in the environment, further optimization is needed to make these immuno-analytical methods more sensitive and easy to use. PMID:23443395

  10. The fabrication of magnetic particle-based chemiluminescence immunoassay for human epididymis protein-4 detection in ovarian cancer.

    PubMed

    Fu, Xiaoling; Liu, Yangyang; Qiu, Ruiyun; Foda, Mohamed F; Zhang, Yong; Wang, Tao; Li, Jinshan

    2018-03-01

    The magnetic particles have a significant influence on the immunoassay detection and cancer therapy. Herein, the chemiluminescence immunoassay combined with the magnetic particles (MPCLIA) was presented for the clinical determination and analysis of human epididymis protein 4 (HE4) in the human serum. Under the optimized experiment conditions, the secure MPCLIA method can detect HE4 in the broader range of 0-1000 pmol/L, with a lower detection limit of 1.35 pmol/L. The satisfactory recovery rate of the method in the serum ranged from 83.62% to 105.10%, which was well within the requirement of clinical analysis. Moreover, the results showed the good correlation with enzyme-linked immunosorbent assay (ELISA), with the correlation coefficient of 0.9589. This proposed method has been successfully applied to the clinical determination of HE4 in the human serum.

  11. An evaluation of the DRI-ETG EIA method for the determination of ethyl glucuronide concentrations in clinical and post-mortem urine.

    PubMed

    Turfus, Sophie C; Vo, Tu; Niehaus, Nadia; Gerostamoulos, Dimitri; Beyer, Jochen

    2013-06-01

    A commercial enzyme immunoassay for the qualitative and semi-quantitative measurement of ethyl glucuronide (EtG) in urine was evaluated. Post-mortem (n=800), and clinical urine (n=200) samples were assayed using a Hitachi 902 analyzer. The determined concentrations were compared with those obtained using a previously published liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantification of EtG and ethyl sulfate. Using a cut-off of 0.5 µg/ml and LC-MS/MS limit of reporting of 0.1 µg/ml, there was a sensitivity of 60.8% and a specificity of 100% for clinical samples. For post-mortem samples, sensitivity and specificity were 82.4% and 97.1%, respectively. When reducing the cut-off to 0.1 µg/ml, the sensitivity and specificity were 83.3% and 100% for clinical samples whereas for post-mortem samples the sensitivity and specificity were 90.3 % and 88.3 %, respectively. The best trade-offs between sensitivity and specificity for LC-MS/MS limits of reporting of 0.5 and 0.1 µg/ml were achieved when using immunoassay cut-offs of 0.3 and 0.092 µg/ml, respectively. There was good correlation between quantitative results obtained by both methods but analysis of samples by LC-MS/MS gave higher concentrations than by enzyme immunoassay (EIA), with a statistically significant proportional bias (P<0.0001, Deming regression) for both sample types. The immunoassay is reliable for the qualitative and semi-quantitative presumptive detection of ethyl glucuronide in urine. Copyright © 2012 John Wiley & Sons, Ltd.

  12. Development of a highly sensitive bioluminescent enzyme immunoassay for hepatitis B virus surface antigen capable of detecting divergent mutants.

    PubMed

    Minekawa, Takayuki; Takehara, Shizuka; Takahashi, Masaharu; Okamoto, Hiroaki

    2013-08-01

    Hepatitis B virus (HBV) infections are sometimes overlooked when using commercial kits to measure hepatitis B virus surface antigen (HBsAg) due to their low sensitivities and reactivities to mutant strains of various genotypes. We developed an ultrasensitive bioluminescent enzyme immunoassay (BLEIA) for HBsAg using firefly luciferase, which is adaptable to a variety of HBsAg mutants, by combining four monoclonal antibodies with a polyclonal antibody against HBsAg. The measurement of seroconversion panels showed trace amounts of HBsAg during the early infection phase by the BLEIA because of its high sensitivity of 5 mIU/ml. The BLEIA detected HBsAg as early as did PCR in five of seven series and from 2.1 to 9.4 days earlier than commercial immunoassay methods. During the late infection phase, the BLEIA successfully detected HBsAg even 40 days after the disappearance of HBV DNA and the emergence of antibodies against HBsAg. The HBsAg BLEIA successfully detected all 13 recombinant HBsAg and 45 types of HBsAg mutants with various mutations within amino acids 90 to 164 in the S gene product. Some specimens had higher values determined by the BLEIA than those by a commercial chemiluminescent immunoassay; this suggests that such discrepancies were caused by the dissociation of preS1/preS2 peptides from the particle surface. With its highly sensitive detection of low-titer HBsAg, including various mutants, the HBsAg BLEIA is considered to be useful for the early diagnosis and prevention of HBV infection because of the shorter window of infection prior to detection, which facilitates early prediction of recurrence in HBV-infected individuals.

  13. Evaluation of an enzyme immunoassay for detection of dengue virus NS1 antigen in human serum.

    PubMed

    Dussart, Philippe; Labeau, Bhety; Lagathu, Gisèle; Louis, Philippe; Nunes, Marcio R T; Rodrigues, Sueli G; Storck-Herrmann, Cécile; Cesaire, Raymond; Morvan, Jacques; Flamand, Marie; Baril, Laurence

    2006-11-01

    We evaluated a one-step sandwich-format microplate enzyme immunoassay for detecting dengue virus NS1 antigen (Ag) in human serum by use of Platelia Dengue NS1 Ag kits (Bio-Rad Laboratories, Marnes La Coquette, France). We collected 299 serum samples from patients with dengue disease and 50 serum samples from patients not infected with dengue virus. For the 239 serum samples from patients with acute infections testing positive by reverse transcription-PCR and/or virus isolation for one of the four dengue virus serotypes, the sensitivity of the Platelia Dengue NS1 Ag kit was 88.7% (95% confidence interval, 84.0% to 92.4%). None of the serum samples from patients not infected with dengue virus tested positive with the Platelia Dengue NS1 Ag kit. A diagnostic strategy combining the Platelia Dengue NS1 Ag test for acute-phase sera and immunoglobulin M capture enzyme-linked immunosorbent assay for early-convalescent-phase sera increased sensitivity only from 88.7% to 91.9%. Thus, NS1 antigen detection with the Platelia Dengue NS1 Ag kit could be used for first-line testing for acute dengue virus infection in clinical diagnostic laboratories.

  14. Detection of anti-nuclear antibody by immunofluorescence assay and enzyme immunoassay in childhood systemic lupus erythematosus: experience from Bangladesh.

    PubMed

    Dipti, Tanjeem Rabika; Azam, Mohammad Shaiful; Sattar, Mohammad Humayun; Rahman, Shahana Akhter

    2012-02-01

    Systemic lupus erythematosus (SLE) is a multisystem, chronic but often episodic, autoimmune disease that is characterized by the presence of antinuclear antibodies (ANA). The criteria set by American College of Rheumatology are widely used for diagnosis of SLE. Elevation of ANA titer is the most sensitive of the ACR criteria. There are different methods for detection of ANA. Indirect immunofluorescence (ANA-IFA) and enzyme immunoassay (ANA-EIA) are commonly used methods. The sensitivity of ANA-IFA using HEp-2 cell substrate is 90-100% in systemic rheumatic diseases. In Bangladesh most of the laboratories use ANA-EIA for detection of ANA. As the sensitivity of ANA-EIA is lower than ANA-IFA it might be that we are missing many cases of ANA positivity in childhood SLE cases. To detect ANA by immunofluorescence assay using HEp-2 cell substrate and enzyme immunoassay in childhood SLE and to compare the diagnostic performance of these methods. This is a cross-sectional analytical study. A total of 40 patients were enrolled. Among them 20 were childhood SLE cases. Another 20 patients of childhood rheumatic diseases other than SLE were taken as the disease control group. In childhood SLE cases, 100% were ANA-positive by IFA and 55% were ANA positive by EIA. The sensitivity of ANA-IFA was 100%. In contrast, sensitivity of ANA-EIA was 55%.   ANA-IFA is superior to ANA-EIA for detection of ANA in childhood SLE patients. ANA-IFA should be the primary screening test for children with clinical features suggestive of SLE. © 2011 The Authors. International Journal of Rheumatic Diseases © 2011 Asia Pacific League of Associations for Rheumatology and Blackwell Publishing Asia Pty Ltd.

  15. Determination of chondroitin-6-sulphate by a competitive enzyme immunoassay using a biotinylated antigen.

    PubMed

    Kähnert, H; Brinkmann, T; Gässler, N; Kleesiek, K

    1994-04-01

    A competitive enzyme immunoassay was developed to determine chondroitin-6-sulphate in body fluids and cell cultures. The assay uses a monoclonal anti-chondroitin-6-sulphate antibody, immobilised to microtitre plates, and it involves a competitive binding reaction between chondroitin-6-sulphate in the samples and the biotinylated antigen. This assay enables the quantification of chondroitin-6-sulphate in the low concentration range of 16-120 micrograms/l. The intra-assay and inter-assay coefficients of variation are below 6.5% and 9.0%, respectively. More than 90% of chondroitin-6-sulphate was recovered when added to 0.1 mol/l phosphate-buffered saline, an albumin solution (40 g/l in phosphate-buffered saline) and cell culture medium (containing 100 ml/l foetal calf serum). Chondroitin-6-sulphate was also determined in sera of healthy male (n = 90) and female (n = 90) blood donors. The normal range was 55-169 micrograms/l. In men the mean value was estimated at 102.2 +/- 37.1 micrograms/l and in women at 98.7 +/- 26.4 micrograms/l. No age or sex dependence was observed. The urine excretion of chondroitin-6-sulphate in men (n = 16) was 44.5 +/- 21.1 mg/kg creatinine (mean +/- standard deviation) and in females (n = 10) 53.5 +/- 21.3 mg/kg creatinine. The clearance rate in men was 0.41 +/- 0.22 ml x min-1 and in women 0.38 +/- 0.15 ml x min-1. No sex dependence was found. Furthermore, the enzyme immunoassay was modified to measure the specific incorporation of a radioactively labelled precursor ([14C]galactosamine) into chondroitin-6-sulphate.(ABSTRACT TRUNCATED AT 250 WORDS)

  16. Determination of metallothionein in biological fluids using enzyme-linked immunoassay with commercial antibody.

    PubMed

    Milnerowicz, Halina; Bizoń, Anna

    2010-01-01

    Metallothionein (MT) is a low molecular weight cysteine-rich protein with a number of roles in the pro/antioxidant balance and homeostasis of essential metals, such as zinc and copper, and in the detoxification of heavy metals, such as cadmium and mercury. Until now, detection of metallothionein in biological fluids remained difficult because of a lack of a broadly reactive commercial test. Meaningful comparison of the values of metallothionein concentrations reported by different authors using their specific isolation procedures and different conditions of enzyme-linked immunoassay is difficult due to the absence of a reference material for metallothionein. Therefore in the present study, we describe a quantitative assay for metallothionein in biological fluids such as plasma and urine performed by a direct enzyme-linked immunoassay using a commercially available monoclonal mouse anti-metallothionein clone E9 antibody and commercial standards of metallothionein from rabbit liver and a custom preparation of metallothionein from human liver. The sensitivity of the assay for the standard containing two isoforms MT-I and MT-II from human liver was 140 pg/well. The reactivity of the commercial standards and standards containing two isoforms MT-I and MT-II isolated from human liver in our laboratory with a commercial monoclonal mouse anti-metallothionein clone E9 antibody were similar. This suggests that the described ELISA test can be useful for determination of metallothionein concentration in biological fluids. The concentrations of metallothionein in human plasma, erythrocyte lysate and in urine of smoking and non-smoking healthy volunteers are reported. Tobacco smoking increases the extracellular metallothionein concentration (plasma and urine) but does not affect the intracellular concentration (erythrocyte lysate).

  17. Clustering and optimal arrangement of enzymes in reaction-diffusion systems.

    PubMed

    Buchner, Alexander; Tostevin, Filipe; Gerland, Ulrich

    2013-05-17

    Enzymes within biochemical pathways are often colocalized, yet the consequences of specific spatial enzyme arrangements remain poorly understood. We study the impact of enzyme arrangement on reaction efficiency within a reaction-diffusion model. The optimal arrangement transitions from a cluster to a distributed profile as a single parameter, which controls the probability of reaction versus diffusive loss of pathway intermediates, is varied. We introduce the concept of enzyme exposure to explain how this transition arises from the stochastic nature of molecular reactions and diffusion.

  18. Association of homocysteine with global DNA methylation in vegetarian Indian pregnant women and neonatal birth anthropometrics.

    PubMed

    Gadgil, Maithili S; Joshi, Kalpana S; Naik, Sadanand S; Pandit, Anand N; Otiv, Suhas R; Patwardhan, Bhushan K

    2014-11-01

    The present study was designed to evaluate if plasma maternal folate, vitamin B-12 and homocysteine levels had an effect on maternal global DNA methylation and neonatal anthropometrics in Indian pregnant women. A total of 49 participants having completed ≥36 weeks of pregnancy were enrolled in the study. Estimation of folate was by Ion capture assay, vitamin B-12 by microparticle enzyme immunoassay, total homocysteine by fluorescence polarization immunoassay and global DNA methylation using Cayman's DNA methylation enzyme immunoassay (EIA) kit. Folate and vitamin B-12 were inversely correlated to homocysteine in pregnant women consuming vegetarian and non-vegetarian diet. No difference in global DNA methylation was found between the vegetarian and non-vegetarian pregnant women. Folate and vitamin B-12 did not show association with global DNA methylation, however plasma total homocysteine of the vegetarian group showed significant correlation to global DNA methylation (r(2 )= 0.49, p = 0.011). Plasma total homocysteine was inversely related to tricep skinfold (r(2 )= -0.484, p = 0.01) and chest circumference (r(2 )= -0.104, p = 0.04) of neonates in vegetarian group. Moderate vitamin B-12 deficiency in vegetarian pregnant women might be the cause of hyperhomocystinemia, hypermethylation when compared to vitamin B-12 sufficient non-vegetarian group.

  19. Detection of antibodies to hepatitis B core antigen using the Abbott ARCHITECT anti-HBc assay: analysis of borderline reactive sera.

    PubMed

    Ollier, Laurence; Laffont, Catherine; Kechkekian, Aurore; Doglio, Alain; Giordanengo, Valérie

    2008-12-01

    Routine use of the automated chemiluminescent microparticle immunoassay Abbott ARCHITECT anti-HBc for diagnosis of hepatitis B is limited in case of borderline reactive sera with low signal close to the cut-off index. In order to determine the significance of anti-HBc detection when borderline reactivity occurs using the ARCHITECT anti-HBc assay, a comparative study was designed. 3540 serum samples collected over a 2-month period in the hospital of Nice were examined for markers of HBV infection (HBsAg, anti-HBs and anti-HBc). One hundred seven samples with sufficient volume and with borderline reactivity by the ARCHITECT assay were tested by two other anti-HBc assays, a microparticle enzyme immunoassay (MEIA, AxSYM Core, Abbott Laboratories, IL, USA) and an enzyme linked fluorescent assay (ELFA, VIDAS Anti-HBc Total II, bioMérieux, Lyon, France). Only 46 samples were confirmed by the AxSYM and the VIDAS assays. Additional serological information linked to patient history showed that the remaining samples (61) were false positives (11), had low titer of anti-HBc antibodies (13), or were inconclusive (37). This comparative study highlighted the existence of a grey zone around the cut-off index. Confirmative results through a different immunoassay are needed to confirm the diagnosis of HBV on borderline reactive sera using the ARCHITECT anti-HBc assay.

  20. Performance of plasma free metanephrines measured by liquid chromatography-tandem mass spectrometry in the diagnosis of pheochromocytoma.

    PubMed

    Peaston, Robert T; Graham, Kendon S; Chambers, Erin; van der Molen, Jan C; Ball, Stephen

    2010-04-02

    Plasma free metanephrines have proved a highly sensitive biochemical test for the diagnosis of pheochromocytoma. We have developed and validated a simple, LC-MS/MS method to determine plasma metanephrines and compared the diagnostic efficacy of the method with an enzyme immunoassay procedure in 151 patients, 38 with histologically confirmed pheochromocytoma. Off-line solid phase extraction in a 96-well plate format was used to isolate metanephrines from 100-microL of plasma, followed by rapid separation with hydrophilic interaction chromatography. Mass spectrometry detection was performed in multiple-reaction monitoring mode using a tandem quadrupole mass spectrometer with positive electrospray ionization. Detection limits were <0.1nmol/l with method linearity up to 23.0nmol/L for normetanephrine (NMN), metanephrine (MN) and 3-methoxytyramine (3-MT). Method comparison with an automated LC-MS/MS yielded Deming regression slopes of r=0.94 for NMN, r=0.98 for MN and r=0.94 for 3-MT. Method comparison with enzyme immunoassay revealed regression slope of r=1.28 (NMN) and 1.25 (MN) with values approximately 25% lower than LC-MS/MS. Plasma metanephrines by LC-MS/MS identified all 38 patients with phaeochromocytoma compared with 36 cases by immunoassay. Plasma metanephrines measured by LC-MS/MS are a reliable and sensitive test for the biochemical detection of pheochromocytoma. 2010 Elsevier B.V. All rights reserved.

  1. Evaluation of ColorPAC Giardia/Cryptosporidium Rapid Assay and ProSpecT Giardia/Cryptosporidium Microplate Assay for Detection of Giardia and Cryptosporidium in Fecal Specimens

    PubMed Central

    Katanik, M. T.; Schneider, S. K.; Rosenblatt, J. E.; Hall, G. S.; Procop, G. W.

    2001-01-01

    Detection of Giardia and Cryptosporidium in clinical stool specimens using the ColorPAC and ProSpecT enzyme immunoassays revealed 98.7% agreement for Giardia detection and 98.1% agreement for Cryptosporidium detection. Sensitivities were uniformly 100%. The specificities of the ColorPAC immunoassay for Giardia and Cryptosporidium detection were 100 and 99.5%, respectively, and those for the ProSpecT assay were 98.4 and 98.6%, respectively. The false-positive reactions with the ProSpecT assay occurred with specimens that were grossly bloody. PMID:11724874

  2. ENZYME IMMUNOASSAY WITH MONOCLONAL ANTIBODIES FOR THE DETECTION OF ROTAVIRUS IN STOOL SPECIMENS

    EPA Science Inventory

    Rotavirus infections are generally recognized as a major problem in young children; however, they have also been associated with severe gastroenteritis in adults and neonates. Infections in neonates are usually asymptomatic, although the incidence of infection may be high. Adult ...

  3. Cost-effectiveness of a modified two-step algorithm using a combined glutamate dehydrogenase/toxin enzyme immunoassay and real-time PCR for the diagnosis of Clostridium difficile infection.

    PubMed

    Vasoo, Shawn; Stevens, Jane; Portillo, Lena; Barza, Ruby; Schejbal, Debra; Wu, May May; Chancey, Christina; Singh, Kamaljit

    2014-02-01

    The analytical performance and cost-effectiveness of the Wampole Toxin A/B EIA, the C. Diff. Quik Chek Complete (CdQCC) (a combined glutamate dehydrogenase antigen/toxin enzyme immunoassay), two RT-PCR assays (Progastro Cd and BD GeneOhm) and a modified two-step algorithm using the CdQCC reflexed to RT-PCR for indeterminate results were compared. The sensitivity of the Wampole Toxin A/B EIA, CdQCC (GDH antigen), BD GeneOhm and Progastro Cd RT-PCR were 85.4%, 95.8%, 100% and 93.8%, respectively. The algorithm provided rapid results for 86% of specimens and the remaining indeterminate results were resolved by RT-PCR, offering the best balance of sensitivity and cost savings per test (algorithm ∼US$13.50/test versus upfront RT-PCR ∼US$26.00/test). Copyright © 2012. Published by Elsevier B.V.

  4. Fieldable, real-time enzyme immunoassay kits for drugs on surfaces

    NASA Astrophysics Data System (ADS)

    Chiappini, Michele W.; Wendel, Gregory J.; Duquette, Peter H.; Hamilton, Martha J.; Chudzik, Stephen J.; Chappa, Ralph A.

    1994-03-01

    Immunoassays (e.g., RIA, EIA) have been demonstrated to be useful for rapid, convenient detection and semiquantitative analysis of drugs. Thermedics Detection, Inc. manufactures a rapid, sensitive, self-contained, disposable, EIA device, developed by Bio-Metric Systems, Inc., designed to allow untrained personnel to perform in field situations. This format has been developed for drugs in biological fluids and on surfaces. The analyte in the test sample competes with an enzyme-analyte conjugate for a limited number of immobilized antibody sites. The AccuPRESS Test format can detect analytes at 10 ppb in biological fluids, water, and soil, and on surfaces, such as suitcases, vehicles, tables and hands, with positive results indicated by clearly visible color development within 5 minutes. This format is designed to have all dry components and to have an ambient shelf life of greater than one year. The format is available for cocaine and opiate derivatives, including heroin, and is readily adaptable for use with numerous other drugs, explosives, and environmental pollutants.

  5. Noninvasive diagnosis of intraamniotic infection: proteomic biomarkers in vaginal fluid.

    PubMed

    Hitti, Jane; Lapidus, Jodi A; Lu, Xinfang; Reddy, Ashok P; Jacob, Thomas; Dasari, Surendra; Eschenbach, David A; Gravett, Michael G; Nagalla, Srinivasa R

    2010-07-01

    We analyzed the vaginal fluid proteome to identify biomarkers of intraamniotic infection among women in preterm labor. Proteome analysis was performed on vaginal fluid specimens from women with preterm labor, using multidimensional liquid chromatography, tandem mass spectrometry, and label-free quantification. Enzyme immunoassays were used to quantify candidate proteins. Classification accuracy for intraamniotic infection (positive amniotic fluid bacterial culture and/or interleukin-6 >2 ng/mL) was evaluated using receiver-operator characteristic curves obtained by logistic regression. Of 170 subjects, 30 (18%) had intraamniotic infection. Vaginal fluid proteome analysis revealed 338 unique proteins. Label-free quantification identified 15 proteins differentially expressed in intraamniotic infection, including acute-phase reactants, immune modulators, high-abundance amniotic fluid proteins and extracellular matrix-signaling factors; these findings were confirmed by enzyme immunoassay. A multi-analyte algorithm showed accurate classification of intraamniotic infection. Vaginal fluid proteome analyses identified proteins capable of discriminating between patients with and without intraamniotic infection. Copyright (c) 2010 Mosby, Inc. All rights reserved.

  6. Detection of Pesticides and Pesticide Metabolites Using the Cross Reactivity of Enzyme Immunoassays

    USGS Publications Warehouse

    Thurman, E.M.; Aga, D.S.

    2001-01-01

    Enzyme immunoassay is an important environmental analysis method that may be used to identify many pesticide analytes in water samples. Because of similarities in chemical structure between various members of a pesticide class, there often may be an unwanted response that is characterized by a percentage of cross reactivity. Also, there may be cross reactivity caused by degradation products of the target analyte that may be present in the sample. In this paper, the concept of cross reactivity caused by degradation products or by nontarget analytes is explored as a tool for identification of metabolites or structurally similar compounds not previously known to be present in water samples. Two examples are examined in this paper from various water quality studies. They are alachlor and its metabolite, alachlor ethane sulfonic acid, and atrazine and its class members, prometryn and propazine. A method for using cross reactivity for the detection of these compounds is explained in this paper.

  7. Galactomannan enzyme immunoassay and quantitative Real Time PCR as tools to evaluate the exposure and response in a rat model of aspergillosis after posaconazole prophylaxis.

    PubMed

    Cendejas-Bueno, Emilio; Forastiero, Agustina; Ruiz, Isabel; Mellado, Emilia; Buitrago, María José; Gavaldà, Joan; Gomez-Lopez, Alicia

    2016-11-01

    A steroid-immunosuppressed rat model of invasive pulmonary aspergillosis was use to examine the usefulness of galactomannan enzyme immunoassay (GM) and quantitative real time PCR (RT-PCR) in evaluating the association between response and exposure after a high dose of prophylactic posaconazole. Two different strains of Aspergillus fumigatus with different in vitro posaconazole susceptibility were used. Serum concentrations demonstrated similar posaconazole exposure for all treated animals. However, response to posaconazole relied on the in vitro susceptibility of the infecting strain. After prophylaxis, galactomannan index and fungal burden only decreased in those animals infected with the most susceptible strain. This study demonstrated that both biomarkers may be useful tools for predicting efficacy of antifungal compounds in prophylaxis. Copyright © 2015 Elsevier España, S.L.U. and Sociedad Española de Enfermedades Infecciosas y Microbiología Clínica. All rights reserved.

  8. Combining supercritical fluid extraction of soil herbicides with enzyme immunoassay analysis.

    PubMed

    Stearman, G K

    2001-10-01

    Supercritical fluid extraction (SFE) of soil herbicides followed by enzyme immunoassay analysis (EIA) is explained in a step-by-step process. Extracted herbicides, include 2,4-D, simazine, atrazine, and alachlor. The herbicide, trifluralin was not successfully analyzed by EIA because of crossreacting metabolites. Problems with SFE, including uneven packing of cells, leaks, uneven flow and clogging, can largely be eliminated as the method parameters are optimized. It was necessary to add modifiers including methanol or acetone to the SF CO2 to increase the solubility of the analytes. Detection limits of 2.5 ng/g soil for atrazine and alachlor and 15 ng/g soil for simazine and 2,4-D without concentration of the sample were achieved. Recoveries above 80% and relative standard deviations (RSDs) less than 15% for 2,4-D simazine, atrazine and alachlor were achieved. Atrazine and alachlor recoveries were above 90% with RSDs below 10%. Forty soil samples could be extracted and analyzed in an 8-h day.

  9. SNAP Assay Technology.

    PubMed

    O'Connor, Thomas P

    2015-12-01

    The most widely used immunoassay configuration is the enzyme-linked immunosorbent assay (ELISA) because the procedure produces highly sensitive and specific results and generally is easy to use. By definition, ELISAs are immunoassays used to detect a substance (typically an antigen or antibody) in which an enzyme is attached (conjugated) to one of the reactants and an enzymatic reaction is used to amplify the signal if the substance is present. Optimized ELISAs include several steps that are performed in sequence using a defined protocol that typically includes application of sample and an enzyme-conjugated antibody or antigen to an immobilized reagent, followed by wash and enzyme reaction steps. The SNAP assay is an in-clinic device that performs each of the ELISA steps in a timed sequential fashion with little consumer interface. The components and mechanical mechanism of the assay device are described. Detailed descriptions of features of the assay, which minimize nonspecific binding and enhance the ability to read results from weak-positive samples, are given. Basic principles used in assays with fundamentally different reaction mechanisms, namely, antigen-detection, antibody-detection, and competitive assays are given. Applications of ELISA technology, which led to the development of several multianalyte SNAP tests capable of testing for up to 6 analytes using a single-sample and a single-SNAP device are described. Copyright © 2016 The Authors. Published by Elsevier Inc. All rights reserved.

  10. Simplified urinary immunoassay for 2,4-D: validation and exposure assessment.

    PubMed

    Lyubimov, A V; Garry, V F; Carlson, R E; Barr, D B; Baker, S E

    2000-08-01

    Urinary monitoring of exposed workers by either analytic chemical methods or radioimmunoassay suggests that urinary levels of 2,4-dichlorophenoxyacetic acid (2,4-D) exceeding 30 ppb are indicative of occupational exposure. However, the current methods do not lend themselves to clinical laboratory use in the rural medical setting. The major goal of this project was to provide medical practitioners who care for members of the agricultural community with a cost-efficient way to conduct exposure assessment. This project used a direct 2,4-D enzyme immunoassay (EIA) and measurement of the ratio between 2,4-D-spiked and non-spiked samples of the same urine to quantify 2,4-D levels. This simplified approach minimizes the effects of non-specific interfering substances in urine and eliminates the need for sample extraction and clean-up. Possible urine co-contaminants (2,4-dichlorophenol and 2,5-dichlorophenol) do not significantly interfere with this immunoassay. Twenty-two forest pesticide applicators who apply and use chlorophenoxy herbicides in their work and 14 comparable control subjects were studied to validate the assay in the occupational setting. Coded urine specimens were examined for levels of 2,4-D by high-performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) and compared with immunoassay results from the same specimens. A correlation coefficient of r = 0.982 with a P value of .0001 for a plot of HPLC-MS/MS versus immunoassay demonstrated that the results from these methods were comparable over urinary dose levels ranging from not detectable (<19 ppb) to 1700 ppb 2,4-D, as determined by immunoassay.

  11. Recombinant antibodies and their use in biosensors.

    PubMed

    Zeng, Xiangqun; Shen, Zhihong; Mernaugh, Ray

    2012-04-01

    Inexpensive, noninvasive immunoassays can be used to quickly detect disease in humans. Immunoassay sensitivity and specificity are decidedly dependent upon high-affinity, antigen-specific antibodies. Antibodies are produced biologically. As such, antibody quality and suitability for use in immunoassays cannot be readily determined or controlled by human intervention. However, the process through which high-quality antibodies can be obtained has been shortened and streamlined by use of genetic engineering and recombinant antibody techniques. Antibodies that traditionally take several months or more to produce when animals are used can now be developed in a few weeks as recombinant antibodies produced in bacteria, yeast, or other cell types. Typically most immunoassays use two or more antibodies or antibody fragments to detect antigens that are indicators of disease. However, a label-free biosensor, for example, a quartz-crystal microbalance (QCM) needs one antibody only. As such, the cost and time needed to design and develop an immunoassay can be substantially reduced if recombinant antibodies and biosensors are used rather than traditional antibody and assay (e.g. enzyme-linked immunosorbant assay, ELISA) methods. Unlike traditional antibodies, recombinant antibodies can be genetically engineered to self-assemble on biosensor surfaces, at high density, and correctly oriented to enhance antigen-binding activity and to increase assay sensitivity, specificity, and stability. Additionally, biosensor surface chemistry and physical and electronic properties can be modified to further increase immunoassay performance above and beyond that obtained by use of traditional methods. This review describes some of the techniques investigators have used to develop highly specific and sensitive, recombinant antibody-based biosensors for detection of antigens in simple or complex biological samples.

  12. Fabricating a UV-Vis and Raman Spectroscopy Immunoassay Platform.

    PubMed

    Hanson, Cynthia; Israelsen, Nathan D; Sieverts, Michael; Vargis, Elizabeth

    2016-11-10

    Immunoassays are used to detect proteins based on the presence of associated antibodies. Because of their extensive use in research and clinical settings, a large infrastructure of immunoassay instruments and materials can be found. For example, 96- and 384-well polystyrene plates are available commercially and have a standard design to accommodate ultraviolet-visible (UV-Vis) spectroscopy machines from various manufacturers. In addition, a wide variety of immunoglobulins, detection tags, and blocking agents for customized immunoassay designs such as enzyme-linked immunosorbent assays (ELISA) are available. Despite the existing infrastructure, standard ELISA kits do not meet all research needs, requiring individualized immunoassay development, which can be expensive and time-consuming. For example, ELISA kits have low multiplexing (detection of more than one analyte at a time) capabilities as they usually depend on fluorescence or colorimetric methods for detection. Colorimetric and fluorescent-based analyses have limited multiplexing capabilities due to broad spectral peaks. In contrast, Raman spectroscopy-based methods have a much greater capability for multiplexing due to narrow emission peaks. Another advantage of Raman spectroscopy is that Raman reporters experience significantly less photobleaching than fluorescent tags 1 . Despite the advantages that Raman reporters have over fluorescent and colorimetric tags, protocols to fabricate Raman-based immunoassays are limited. The purpose of this paper is to provide a protocol to prepare functionalized probes to use in conjunction with polystyrene plates for direct detection of analytes by UV-Vis analysis and Raman spectroscopy. This protocol will allow researchers to take a do-it-yourself approach for future multi-analyte detection while capitalizing on pre-established infrastructure.

  13. Homogeneous Immunoassays: Historical Perspective and Future Promise

    NASA Astrophysics Data System (ADS)

    Ullman, Edwin F.

    1999-06-01

    The founding and growth of Syva Company is examined in the context of its leadership role in the development of homogeneous immunoassays. The simple mix and read protocols of these methods offer advantages in routine analytical and clinical applications. Early homogeneous methods were based on insensitive detection of immunoprecipitation during antigen/antibody binding. The advent of reporter groups in biology provided a means of quantitating immunochemical binding by labeling antibody or antigen and physically separating label incorporated into immune complexes from free label. Although high sensitivity was achieved, quantitative separations were experimentally demanding. Only when it became apparent that reporter groups could provide information, not only about the location of a molecule but also about its microscopic environment, was it possible to design practical non-separation methods. The evolution of early homogenous immunoassays was driven largely by the development of improved detection strategies. The first commercial spin immunoassays, developed by Syva for drug abuse testing during the Vietnam war, were followed by increasingly powerful methods such as immunochemical modulation of enzyme activity, fluorescence, and photo-induced chemiluminescence. Homogeneous methods that quantify analytes at femtomolar concentrations within a few minutes now offer important new opportunities in clinical diagnostics, nucleic acid detection and drug discovery.

  14. COMPARISON OF IMMUNOASSAY AND GAS CHROMATOGRAPHY/MASS SPECTROMETRY FOR MEASUREMENT OF POLYCYCLIC AROMATIC HYDROCARBONS IN CONTAMINATED SOIL

    EPA Science Inventory

    Polycyclic aromatic hydrocarbons (PAHs) are frequently encountered in the environment and may pose health concerns due to their carcinogenicity. A commercial enzyme-linked immunosorbent assay (ELISA), was evaluated as a screening method for monitoring PAHs at contaminated site...

  15. DEVELOPMENT OF A CLASS-SPECIFIC IMMUNOASSAY FOR THE TYPE I PYRETHROID INSECTICIDES. (R825433)

    EPA Science Inventory

    A general enzyme-linked immunosorbent assay was developed for the type I pyrethroid insecticides, such as permethrin, phenothrin, resmethrin and bioresmethrin. Polyclonal antibodies were generated by immunizing with a permethrin derivative, 2,2-dimethyl-3-(5′-carboxy-pe...

  16. Computer-assisted enzyme immunoassays and simplified immunofluorescence assays: applications for the diagnostic laboratory and the veterinarian's office.

    PubMed

    Jacobson, R H; Downing, D R; Lynch, T J

    1982-11-15

    A computer-assisted enzyme-linked immunosorbent assay (ELISA) system, based on kinetics of the reaction between substrate and enzyme molecules, was developed for testing large numbers of sera in laboratory applications. Systematic and random errors associated with conventional ELISA technique were identified leading to results formulated on a statistically validated, objective, and standardized basis. In a parallel development, an inexpensive system for field and veterinary office applications contained many of the qualities of the computer-assisted ELISA. This system uses a fluorogenic indicator (rather than the enzyme-substrate interaction) in a rapid test (15 to 20 minutes' duration) which promises broad application in serodiagnosis.

  17. A competitive enzyme immunoassay for the quantitative detection of cocaine from banknotes and latent fingermarks.

    PubMed

    van der Heide, Susan; Garcia Calavia, Paula; Hardwick, Sheila; Hudson, Simon; Wolff, Kim; Russell, David A

    2015-05-01

    A sensitive and versatile competitive enzyme immunoassay (cEIA) has been developed for the quantitative detection of cocaine in complex forensic samples. Polyclonal anti-cocaine antibody was purified from serum and deposited onto microtiter plates. The concentration of the cocaine antibody adsorbed onto the plates, and the dilution of the cocaine-HRP hapten were both studied to achieve an optimised immunoassay. The method was successfully used to quantify cocaine in extracts taken from both paper currency and latent fingermarks. The limit of detection (LOD) of 0.162ngmL(-1) achieved with the assay compares favourably to that of conventional chromatography-mass spectroscopy techniques, with an appropriate sensitivity for the quantification of cocaine at the low concentrations present in some forensic samples. The cEIA was directly compared to LC-MS for the analysis of ten UK banknote samples. The results obtained from both techniques were statistically similar, suggesting that the immunoassay was unaffected by cross-reactivity with potentially interfering compounds. The cEIA was used also for the detection of cocaine in extracts from latent fingermarks. The results obtained were compared to the cocaine concentrations detected in oral fluid sampled from the same individual. Using the cEIA, we have shown, for the first time, that endogeneously excreted cocaine can be detected and quantified from a single latent fingermark. Additionally, it has been shown that the presence of cocaine, at similar concentrations, in more than one latent fingermark from the same individual can be linked with those concentrations found in oral fluid. These results show that detection of drugs in latent fingermarks could directly indicate whether an individual has consumed the drug. The specificity and feasibility of measuring low concentrations of cocaine in complex forensic samples demonstrate the effectiveness and robustness of the assay. The immunoassay presents a simple and cost-effective alternative to the current mass spectrometry based techniques for the quantitation of cocaine at forensically significant concentrations. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  18. Practical colorimeter for direct measurement of microplates in enzyme immunoassay systems.

    PubMed

    Clem, T R; Yolken, R H

    1978-01-01

    A colorimeter capable of measuring results of enzyme-linked immunosorbent assay (ELISA) reactions directly in the wells of a microtiter plate is described. This colorimeter proved to be as accurate as a conventional spectrophotometer in assessing ELISA reactions, but had the advantage of not requiring transfer of the specimen to a separate chamber. With this colorimeter, 96 specimens can be read in approximately 5 min. A practical colorimeter such as this can make the use of ELISA tests more feasible for many laboratories.

  19. Binding Assays for the Quantitative Detection of P. brevis Polyether Neurotoxins in Biological Samples and Antibodies as Therapeutic Aids for Polyether Marine Intoxication

    DTIC Science & Technology

    1987-12-01

    editions are obsolete. -I Block 19 continued structure. Preliminary experiments involving conversion of the radio- immunoassay to a urease enzyme linked...the radioimmunoassay to a urease I enzyme linked form have been successful. DTIC GTAB Di tributioul AV~i~b~±~YCoded Avsi abi11i ntY___ tat Special...necessary prior to thin- layer chromatography. A preparative thin- layer chromatography step using silica gel plates (1000 u thickness) utilizes acetone

  20. Partial purification and characterization of a Ca(2+)-dependent protein kinase from the green alga, Dunaliella salina

    NASA Technical Reports Server (NTRS)

    Roux, S. J.

    1990-01-01

    A calcium-dependent protein kinase was partially purified and characterized from the green alga Dunaliella salina. The enzyme was activated at free Ca2+ concentrations above 10(-7) molar. and half-maximal activation was at about 3 x 10(-7) molar. The optimum pH for its Ca(2+)-dependent activity was 7.5. The addition of various phospholipids and diolein had no effects on enzyme activity and did not alter the sensitivity of the enzyme toward Ca2+. The enzyme was inhibited by calmodulin antagonists, N-(6-aminohexyl)-1-naphthalene sulfonamide and N-(6-aminohexyl)-5-chloro-1-naphthalene sulfonamide in a dose-dependent manner while the protein kinase C inhibitor, sphingosine, had little effect on enzyme activity up to 800 micromolar. Immunoassay showed some calmodulin was present in the kinase preparations. However, it is unlikely the kinase was calmodulin regulated, since it still showed stimulation by Ca2+ in gel assays after being electrophoretically separated from calmodulin by two different methods. This gel method of detection of the enzyme indicated that a protein band with an apparent molecular weight of 40,000 showed protein kinase activity at each one of the several steps in the purification procedure. Gel assay analysis also showed that after native gel isoelectric focusing the partially purified kinase preparations had two bands with calcium-dependent activity, at isoelectric points 6.7 and 7.1. By molecular weight, by isoelectric point, and by a comparative immunoassay, the Dunaliella kinase appears to differ from at least some of the calcium-dependent, but calmodulin and phospholipid independent kinases described from higher plants.

  1. Microglia cyclooxygenase-2 activity in experimental gliomas: possible role in cerebral edema formation.

    PubMed

    Badie, Behnam; Schartner, Jill M; Hagar, Aaron R; Prabakaran, Sakthivel; Peebles, Todd R; Bartley, Becky; Lapsiwala, Samir; Resnick, Daniel K; Vorpahl, Jessica

    2003-02-01

    Cerebral edema is responsible for significant morbidity and mortality in patients harboring malignant gliomas. To examine the role of inflammatory cells in brain edema formation, we studied the expression cyclooxygenase (COX)-2, a key enzyme in arachidonic acid metabolism, by microglia in the C6 rodent glioma model. The expression of COX-2 in primary microglia cultures obtained from intracranial rat C6 gliomas was examined using reverse transcription-PCR, Western analysis, and prostaglandin E(2) (PGE(2)) enzyme immunoassay. Blood-tumor barrier permeability was studied in the same tumor model using magnetic resonance imaging. In contrast to C6 glioma cells, microglia isolated from intracranial C6 tumors produced high levels of PGE(2) through a COX-2-dependent pathway. To test whether the observed microglia COX-2 activity played a role in brain edema formation in gliomas, tumor-bearing rats were treated with rofecoxib, a selective COX-2 inhibitor. Rofecoxib was as effective as dexamethasone in decreasing the diffusion of contrast material into the brain parenchyma (P = 0.01, rofecoxib versus control animals), suggesting a reduction in blood-tumor barrier permeability. These findings suggest that glioma-infiltrating microglia are a major source of PGE(2) production through the COX-2 pathway and support the use of COX-2 inhibitors as possible alternatives to glucocorticoids in the treatment of peritumoral edema in patients with malignant brain tumors.

  2. Electrokinetic Microstrirring to Enhance Immunoassays

    NASA Astrophysics Data System (ADS)

    Feldman, Hope; Sigurdson, Marin; Meinhart, Carl

    2006-11-01

    Electrokinetic microstirring is used to improve the sensitivity of microfluidic heterogeneous immuno-sensors by enhancing the transport in diffusion-limited reactions. The AC electrokinetic force, Electrothermal Flow, is exploited to create a circular stirring fluid motion, thereby providing more binding opportunities between suspended and wall-immobilized molecules. This process can significantly reduce test times, important for both field-portable biosensors and for lab-based assays. A 2-D numerical simulation model is used to predict the effect of electrothermal flow on a heterogeneous immunoassay resulting from an AC potential applied to two parallel electrodes. The binding is increased by a factor of 7 for an applied voltage of 10 Vrms. The effect was investigated experimentally using a high affinity biotin-streptavidin reaction. Microstirred reaction rates were compared with passive reactions. The measurements show on average an order of magnitude increase in binding between immobilized biotin and fluorescently-labeled streptavidin after 5 minutes. Therefore, this technique shows significant promise for reducing incubation time and enhancing the sensitivity of immunoassays.

  3. Integration of minisolenoids in microfluidic device for magnetic bead-based immunoassays

    NASA Astrophysics Data System (ADS)

    Liu, Yan-Jun; Guo, Shi-Shang; Zhang, Zhi-Ling; Huang, Wei-Hua; Baigl, Damien; Chen, Yong; Pang, Dai-Wen

    2007-10-01

    Microfluidic devices with integrated minisolenoids, microvalves, and channels have been fabricated for fast and low-volume immunoassay using superparamagnetic beads and well-known surface bioengineering protocols. A magnetic reaction area can be formed in the microchannel, featuring a high surface-to-volume ratio and low diffusion distances for the reagents to the bead surface. Such a method has the obvious advantage of easy implementation at low cost. Moreover, the minisolenoids can be switched on or off and the magnetic field intensity can be tuned on demand. Fluids can be manipulated by controlling the integrated air-pressure-actuated microvalves. Accordingly, magnetic bead-based immunoassay, as a typical example of biochemical detection and analysis, has been successfully performed on the integrated microfluidic device automatically in longitudinal mode. With a sample consumption of 0.5μl and a total assay time of less than 15min, goat immunoglobulin G was detected and the method exhibited a detection limit of 4.7ng/ml.

  4. Epidemic of Febrile Disease in Berbera, Somalia

    DTIC Science & Technology

    1993-10-01

    situated on the Gulf all negative by Widal tests. In July 1989, of Aden, adjacent to the Indian Ocean , is a a U.S. Navy team administered a coastal town...A. (1976): Microplate enzyme linked immunosorbent assay antibody immunoassays for the immunodiagnosis response to C. burnetii in experimentally of

  5. Method 546: Determination of Total Microcystins and Nodularins in Drinking Water and Ambient Water by Adda Enzyme-Linked Immunosorbent Assay

    EPA Pesticide Factsheets

    This method is listed as Tier I for presumptive analysis of microcystins in water samples and Tier II all other environmental sample types. The method determines total microcystins and nodularins using an indirect competitive immunoassay (ELISA).

  6. Tobago Prostate Survey: Prostate Cancer Risk in a Large Population-Based Study of Men of African Descent

    DTIC Science & Technology

    2001-06-01

    Pittsburgh Central Pathology Laboratory using the automated Microparticle Enzyme Immunoassay, Abbot AxSYM PSA assay (Abbott Laboratories, Abbott Park, IL, USA...1997) pesticide applicators in Sweden (Dich & Wik/und, 1998) "* No evidence of an association (Giovannuccietal., 1997; * Increased risk for soap

  7. Immuno-PCR assay for sensitive detection of proteins in real time

    USDA-ARS?s Scientific Manuscript database

    The immuno-PCR (IPCR) assay combines the versatility and robustness of immunoassays with the exponential signal amplification power of the polymerase chain reaction (PCR). Typically, IPCR allows a 10–1,000-fold increase in sensitivity over the analogous enzyme-linked immunosorbent assay (ELISA). Thi...

  8. Screening for cocaine on Euro banknotes by a highly sensitive enzyme immunoassay.

    PubMed

    Abdelshafi, Nahla A; Panne, Ulrich; Schneider, Rudolf J

    2017-04-01

    This study focused on quantitative detection of cocaine on Euro banknotes in Germany. A sensitive direct competitive immunoassay was developed and optimized with a limit of detection (LOD) of 5.6ng/L. Exhaustive cocaine extraction by solvent was tested using different methanol concentrations and buffered solutions. Cross-reactivity studies were performed to determine the degree of interference of cocaine metabolites with the immunoassay. Sixty-five Euro banknotes obtained from different districts in Berlin were evaluated. A 100% contamination frequency with cocaine was detected. A comparison between the amount of cocaine extracted by cotton swabbing of one square centimeter of the banknote showed a good correlation for lower contamination levels. This assay showed high sensitivity of detecting pg of cocaine per 1cm 2 of one banknote by swabbing 1cm 2 : 0, 14, and 21pg/cm 2 . Moreover, three notes of different denominations revealed high cocaine concentration; 1.1mg/note, and twice 55µg/note. Copyright © 2017 Elsevier B.V. All rights reserved.

  9. Gold Nanoparticle Labels and Heterogeneous Immunoassays: The Case for the Inverted Substrate.

    PubMed

    Crawford, Alexis C; Young, Colin C; Porter, Marc D

    2018-06-15

    This paper examines how the difference in the spatial orientation of the capture substrate influences the analytical sensitivity and limits of detection for immunoassays that use gold nanoparticle labels (AuNPs) and rely on diffusion in quiet solution in the antigen capture and labeling steps. Ideally, the accumulation of both reactants should follow a dependence governed by the rate in which diffusion delivers reactants to the capture surface. In other words, the accumulation of reactants should increase with the square root of the incubation time, i.e., t1/2. The work herein shows, however, that this expectation is only obeyed when the capture substrate is oriented to direct the gravity-induced sedimentation of the AuNP labels away from the substrate. Using an assay for human IgG, the results show that circumventing the sedimentation of the gold nanoparticle labels by substrate inversion enables the dependence of the labeling step on diffusion, reduces nonspecific label adsorption, and improves the estimated detection limit by ~30×. High-density maps of the signal across the two types of substrates also demonstrate that inversion in the labeling step results in a more uniform distribution of AuNP labels across the surface, which translates to a greater measurement reproducibility. These results, which are supported by model simulations via the Mason-Weaver sedimentation-diffusion equation, and their potential implications when using other nanoparticle labels and related materials in diagnostic tests and other applications, are briefly discussed.

  10. The Occurrence of Abscisic Acid and Abscisyl-β-d-Glucopyranoside in Developing and Mature Citrus Fruit as Determined by Enzyme Immunoassay 1

    PubMed Central

    Harris, Michael J.; Dugger, William M.

    1986-01-01

    The contents of (+)-cis-abscisic acid (ABA) and alkaline-hydrolyzable ABA-conjugate(s) were analyzed by means of enzyme immunoassay in partially purified extracts of developing and mature sweet orange fruit (Citrus sinensis [L.] Osbeck cv Washington navel). A relatively small increase in ABA was observed in the fruit exocarp during the natural color transition from green to orange. At the same time, the ABA-conjugate level increased approximately 12-fold in this tissue. The contents of ABA and ABA-conjugate equaled 15.0 ± 0.7 and 107.8 ± 2.1 nanomoles per gram fresh weight, respectively, in the exocarp at harvest. Other tissues also contained considerable quantities of these compounds. Whereas the highest ABA content was observed in the exocarp, the highest ABA-conjugate content was observed in the central vascular axis of the fruit and equaled 187.0 ± 10.3 nanomoles per gram fresh weight. The only immunoreactive conjugate found in significant quantity in mature fruit was identified as abscisyl-β-d-glucopyranoside (ABA-GE) based on (a) immunological cross-reactivity, (b) thin layer chromatography co-chromatography with authentic standards in two solvent systems, (c) susceptibility to both chemical and enzymic degradation, and (d) mass spectroscopy. PMID:16665032

  11. Rapid determination of recent cocaine use with magnetic particles-based enzyme immunoassays in serum, saliva, and urine fluids.

    PubMed

    Vidal, Juan C; Bertolín, Juan R; Bonel, Laura; Asturias, Laura; Arcos-Martínez, M Julia; Castillo, Juan R

    2016-06-05

    Cocaine is one of the most worldwide used illicit drugs. We report a magnetic particles-based enzyme-linked immunoassay (mpEIA) method for the rapid and sensitive determination of cocaine (COC) in saliva, urine and serum samples. Under optimized conditions, the limits of detections were 0.09ngmL(-1) (urine), 0.15ngmL(-1) (saliva), and 0.06ngmL(-1) COC (human serum). Sensitivities were in the range EC50=0.6-2.5ngmL(-1) COC. The cross-reactivity with the principal metabolite benzoylecgonine (BZE) was only 1.6%. Recovering percentages of doped samples (0, 10, 50, and 100ngmL(-1) of COC) ranged from about 86-111%. Some advantages of the developed mpEIA over conventional ELISA kits are faster incubations, improved reproducibility, and consumption of lower amounts of antibody and enzyme conjugates due to the use of magnetic beads. The reported method was validated following the guidelines on bioanalytical methods of the European Medicines Agency (2011). Unmetabolized COC detection has a great interest in pharmacological, pharmacokinetics, and toxicokinetics studies, and can be used to detect a very recent COC use (1-6h). Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Industrial Fungal Enzymes: An Occupational Allergen Perspective

    PubMed Central

    Green, Brett J.; Beezhold, Donald H.

    2011-01-01

    Occupational exposure to high-molecular-weight allergens is a risk factor for the development and pathogenesis of IgE-mediated respiratory disease. In some occupational environments, workers are at an increased risk of exposure to fungal enzymes used in industrial production. Fungal enzymes have been associated with adverse health effects in the work place, in particular in baking occupations. Exposure-response relationships have been demonstrated, and atopic workers directly handling fungal enzymes are at an increased risk for IgE-mediated disease and occupational asthma. The utilization of new and emerging fungal enzymes in industrial production will present new occupational exposures. The production of antibody-based immunoassays is necessary for the assessment of occupational exposure and the development of threshold limit values. Allergen avoidance strategies including personal protective equipment, engineering controls, protein encapsulation, and reduction of airborne enzyme concentrations are required to mitigate occupational exposure to fungal enzymes. PMID:21747869

  13. Multilayers enzyme-coated carbon nanotubes as biolabel for ultrasensitive chemiluminescence immunoassay of cancer biomarker.

    PubMed

    Bi, Sai; Zhou, Hong; Zhang, Shusheng

    2009-06-15

    A novel and ultrasensitive chemiluminescence immunoassay (CLIA) method based on multiple enzyme layers assembled multiwall carbon nanotubes (MWCNTs) as signal amplification labels was developed by employing luminol-H(2)O(2)-HRP-bromophenol blue (BPB) enhanced chemiluminescence (CL) system for the detection of a cancer biomarker in human serum samples, as exemplified by the measurement of alpha-fetoprotein (AFP) as a model protein. In this study, horseradish peroxidase (HRP) was assembled onto MWCNTs templates layer-by-layer (LBL) through electrostatic interactions with polyion PDDA, and further conjugated with AFP secondary antibodies (Ab(2)) as the enzyme label. The resulting LBL assembly could maximize the ratio of HRP/Ab(2) which could amplify the sensitivity greatly. To the best of our knowledge, it was the first time for this strategy applied in CLIA to date. Under the optimum conditions of luminol-H(2)O(2)-HRP-BPB CL system and the sandwich immunoreactions, a linear range from 0.02 to 2.0 ng/mL (R=0.9980) was obtained with the detection limit of 8.0 pg/mL (3sigma) which was two orders of magnitude lower than standard ELISA method. Furthermore, accurate detection of AFP in human serum samples was also demonstrated by comparison to ELISA assays. From the above results, such signal amplification strategy proposed by the novel CNT-LBL enzyme label showed an excellent promise for ultrasensitive detection of cancer biomarkers in clinical laboratory.

  14. A novel fluorescence immunoassay for the sensitive detection of Escherichia coli O157:H7 in milk based on catalase-mediated fluorescence quenching of CdTe quantum dots.

    PubMed

    Chen, Rui; Huang, Xiaolin; Li, Juan; Shan, Shan; Lai, Weihua; Xiong, Yonghua

    2016-12-01

    Immunoassay is a powerful tool for rapid detection of food borne pathogens in food safety monitoring. However, conventional immunoassay always suffers from low sensitivity when it employs enzyme-catalyzing chromogenic substrates to generate colored molecules as signal outputs. In the present study, we report a novel fluorescence immunoassay for the sensitive detection of E. coli O157:H7 through combination of the ultrahigh bioactivity of catalase to hydrogen peroxide (H 2 O 2 ) and H 2 O 2 -sensitive mercaptopropionic acid modified CdTe QDs (MPA-QDs) as a signal transduction. Various parameters, including the concentrations of anti-E. coli O157:H7 polyclonal antibody and biotinylated monoclonal antibody, the amounts of H 2 O 2 and streptavidin labeled catalase (CAT), the hydrolysis temperature and time of CAT to H 2 O 2 , as well as the incubation time between H 2 O 2 and MPA-QDs, were systematically investigated and optimized. With optimal conditions, the catalase-mediated fluorescence quenching immunoassay exhibits an excellent sensitivity for E. coli O157:H7 with a detection limit of 5 × 10 2  CFU/mL, which was approximately 140 times lower than that of horseradish peroxidase-based colorimetric immunoassay. The reliability of the proposed method was further evaluated using E. coli O157:H7 spiked milk samples. The average recoveries of E. coli O157:H7 concentrations from 1.18 × 10 3  CFU/mL to 1.18 × 10 6  CFU/mL were in the range of 65.88%-105.6%. In brief, the proposed immunoassay offers a great potential for rapid and sensitive detection of other pathogens in food quality control. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Evaluation of a new amplified enzyme immunoassay (EIA) for the detection of Chlamydia trachomatis in male urine, female endocervical swab, and patient obtained vaginal swab specimens

    PubMed Central

    Tanaka, M.; Nakayama, H.; Sagiyama, K.; Haraoka, M.; Yoshida, H.; Hagiwara, T.; Akazawa, K.; Naito, S.

    2000-01-01

    Aims—To compare the performance of a new generation dual amplified enzyme immunoassay (EIA) with a molecular method for the diagnosis of Chlamydia trachomatis, using a range of urogenital samples, and to assess the reliability of testing self collected vaginal specimens compared with clinician collected vaginal specimens. Methods—Two population groups were tested. For the first population group, first void urine samples were collected from 193 male patients with urethritis, and endocervical swabs were collected from 187 high risk commercial sex workers. All urine and endocervical specimens were tested by a conventional assay (IDEIA chlamydia), a new generation amplified immunoassay (IDEIA PCE chlamydia), and the Amplicor polymerase chain reaction (PCR). Discrepant results obtained among the three sample types were confirmed using a nested PCR test with a different plasmid target region. For the second population group, four swab specimens, including one patient obtained vaginal swab, two clinician obtained endocervical swabs, and one clinician obtained vaginal swab, were collected from 91 high risk sex workers. Self collected and clinician collected vaginal swabs were tested by IDEIA PCE chlamydia. Clinician obtained endocervical swabs were assayed by IDEIA PCE chlamydia and Amplicor PCR. Results—The performance of the IDEIA PCE chlamydia test was comparable to that of the Amplicor PCR test when male urine and female endocervical swab specimens were analysed. The relative sensitivities of IDEIA, IDEIA PCE, and Amplicor PCR on male first void urine specimens were 79.3%, 91.4%, and 100%, respectively. The relative sensitivities of the three tests on female endocervical specimens were 85.0%, 95.0%, and 100%, respectively. The positivity rates for patient collected vaginal specimens and clinician collected vaginal specimens by IDEIA PCE were 25.2% and 23.1%, respectively, whereas those for clinician collected endocervical swabs by PCR and IDEIA PCE were both 27.5%. Conclusions—IDEIA PCE chlamydia is a lower cost but sensitive alternative test to PCR for testing male urine samples and female endocervical swabs. In addition, self collected or clinician collected vaginal specimens tested by IDEIA PCE chlamydia are a reliable alternative to analysing endocervical specimens. Key Words: Chlamydia trachomatis • enzyme immunoassay • clinical specimens PMID:10889816

  16. Measurements in international units of antibody to hepatitis B surface antigen(anti-HBs) after immunization with a yeast-derived, subtype adr hepatitis B vaccine are considerably different between chemiluminescent immunoassay (CLIA) and chemiluminescent enzyme immunoassay (CLEIA).

    PubMed

    Ogata, Norio

    2006-04-01

    The worldwide consensus of the minimum protective anti-HBs level against HBV infection is 10 mIU/mL on assays standardized by the World Health Organization (WHO) reference preparations. To investigate whether this value could be applied to recipients of yeast-derived recombinant HB vaccine containing the major surface protein of subtype adr (Bimmugen, Astellas Pharmaceutical, Tokyo), we compared anti-HBs measurements between chemiluminescent immunoassay (CLIA) (Architect Ausab, Abbott Japan, Tokyo) and chemiluminescent enzyme immunoassay (CLEIA) (Lumipulse Forte, Fujirebio, Tokyo) in given serum samples obtained from the vaccinees. The vaccine and the two assay methods are currently in a wide use in Japan. The study included 300 medical students who completed a standard vaccination course (0, 1 and 6 months). Serum samples obtained 1 month or 13 months after completing the vaccination were simultaneously tested for anti-HBs by CLIA and CLEIA. In 147 samples with quantifiable values on both CLIA and CLEIA (10 to 1000 mIU/mL) the geometric mean titer on CLEIA (225.0 mIU/mL) was significantly higher than that on CLIA (94.5 mIU/mL) (p < 0.0001). Of 26 subjects with CLIA measurements below 10 mIU/mL, 15 samples (57.7%) showed CLEIA measurements more than 10 mIU/mL. Thus, in the subtype adr-vaccinees CLEIA demonstrated considerably high serum anti-HBs measurements compared to CLIA and discordance in determining critical anti-HBs level of 10 mIU/mL was observed in more than half the samples. This suggests that the minimum HBV-protective anti HBs titer of 10 mIU/mL is difficult to be introduced to Japan where subtype adr-HB vaccines or -HBV infection are prevalent, unless characteristics of assay methods are carefully evaluated.

  17. Reliability of the cloned-enzyme donor immunoassay (CEDIA) for cocaine in human serum in the range between the detection limit and the cut-off.

    PubMed

    Schütz, Harald; Auch, Jürgen; Erdmann, Freidoon; Weiler, Günter; Verhoff, Marcel A

    2006-01-01

    Immunoassays are used worldwide for the rapid screening of drugs. Despite the fact that they are highly valuable tools for the testing of legal and illicit drugs, there is a non-negligable risk of false-positive and false-negative findings and many pitfalls must be taken into account when using these tests in an uncritical manner and without valid confirmation procedures. In order to check the correlation between cloned-enzyme donor immunoassay (CEDIA) readings and exact determined gas chromatography/mass spectrometry (GC/MS) values for benzoylecgonine, a total of 472 serum samples was measured with an immunoassay (CEDIA) as well as GC/MS. As a result, it was shown that in the lower area of concentration, up to approx. 300 ng equ. benzoylecgonine/ml, there is a semiquantitative useful correlation. With higher concentrations, the values shift more and more apart and many runaways are visible. Generally the use of tests for materials other than those declared is excluded from the manufacturer's warranty and is at the user's own risk, but the authors found that many immunochemical tests with a certification only for the use in urine are well suited to the screening of serum samples, and even low readings could be confirmed by GC/MS. With blood or serum as sample, it could be regularly observed that generally very small readings could not only be confirmed with mass spectrometry but could in most cases also be quantified. This was the key factor in determining the rate of confirmation in 495 cases. In total, an incredibly high reliability for the CEDIA cocaine test (via benzoylecgonine) was shown up to the area of detection (detection limit), far below the cut-off. These results confirm the extraordinary sensitivity and specificity of this test also for blood or serum as sample material to be tested.

  18. Evaluation of nine immunoassay kits (enzyme immunoassay and direct fluorescence) for detection of Giardia lamblia and Cryptosporidium parvum in human fecal specimens.

    PubMed Central

    Garcia, L S; Shimizu, R Y

    1997-01-01

    It is well known that Giardia lamblia and Cryptosporidium parvum can cause severe symptoms in humans, particularly those who are immunologically compromised. Immunoassay procedures offer both increased sensitivity and specificity compared to conventional staining methods. These reagents are also helpful when screening large numbers of patients, particularly in an outbreak situation or when screening patients with minimal symptoms. The data obtained by using 9 diagnostic kits were compared: direct fluorescent-antibody assay (DFA) kits (TechLab Giardia/Crypto IF kit, TechLab Crypto IF kit, and Meridian Merifluor Cryptosporidium/Giardia) and enzyme immunoassay (EIA) kits (Alexon ProSpecT Giardia EZ Microplate Assay, Alexon ProSpecT Cryptosporidium Microplate Assay, Cambridge Giardia lamblia Antigen Microwell ELISA, Meridian Premier Giardia lamblia, Meridian Premier Cryptosporidium, TechLab Giardia CELISA, Trend Giardia lamblia EIA). The test with the Meridian Merifluor Cryptosporidium/Giardia kit was used as the reference method. In various combinations, 60 specimens positive for Giardia, 60 specimens positive for Cryptosporidium, 40 specimens positive for a Giardia-Cryptosporidium mix, and 50 negative fecal specimens were tested. Different species (nine protozoa, three coccidia, one microsporidium, five nematodes, three cestodes, and one trematode) were included in the negative specimens. The sensitivity of EIA for Giardia ranged from 94% (Alexon) to 99% (Trend and Cambridge); the specificity was 100% with all EIA kits tested. The sensitivity of EIA for Cryptosporidium ranged from 98% (Alexon) to 99% (Meridian Premier); specificities were 100%. All DFA results were in agreement, with 100% sensitivity and specificity; however, the TechLab reagents resulted in fluorescence intensity that was generally one level below that seen with the reagents used in the reference method. In addition to sensitivity and specificity, factors such as cost, simplicity, ease of interpretation of results (color, intensity of fluorescence), equipment, available personnel, and number of tests ordered are also important considerations prior to kit selection. PMID:9163474

  19. Detection of alpha-fetoprotein in magnetic immunoassay of thin channels using biofunctional nanoparticles

    NASA Astrophysics Data System (ADS)

    Tsai, H. Y.; Gao, B. Z.; Yang, S. F.; Li, C. S.; Fuh, C. Bor

    2014-01-01

    This paper presents the use of fluorescent biofunctional nanoparticles (10-30 nm) to detect alpha-fetoprotein (AFP) in a thin-channel magnetic immunoassay. We used an AFP model biomarker and s-shaped deposition zones to test the proposed detection method. The results show that the detection using fluorescent biofunctional nanoparticle has a higher throughput than that of functional microparticle used in previous experiments on affinity reactions. The proposed method takes about 3 min (versus 150 min of previous method) to detect 100 samples. The proposed method is useful for screening biomarkers in clinical applications, and can reduce the run time for sandwich immunoassays to less than 20 min. The detection limits (0.06 pg/ml) and linear ranges (0.068 pg/ml-0.68 ng/ml) of AFP using fluorescent biofunctional nanoparticles are the same as those of using functional microparticles within experimental errors. This detection limit is substantially lower and the linear range is considerably wider than those of enzyme-linked immunosorbent assay (ELISA) and other methods in sandwich immunoassay methods. The differences between this method and an ELISA in AFP measurements of serum samples were less than 12 %. The proposed method provides simple, fast, and sensitive detection with a high throughput for biomarkers.

  20. Development and comparison of three diagnostic immunoassay formats for the detection of azoxystrobin.

    PubMed

    Furzer, Gordon S; Veldhuis, Linda; Hall, J Christopher

    2006-02-08

    The currently accepted method of detection for azoxystrobin, a strobilurin fungicide, involves a labor-intensive organic solvent extraction and gas chromatography analysis. Three diagnostic assay formats, i.e., enzyme-linked immunosorbent assay (ELISA), fluorescence polarization (FP), and time-resolved fluorescence (TR-FIA), were developed and compared with regard to detection and quantification of azoxystrobin in grape extract and river, lake, and well water samples. These three assay formats require no initial sample extraction and were not affected by any of the environmental matrices tested, and each had a linear working range of 0-400 pg/mL. The polyclonal antibodies used for each of the immunoassays were specific to azoxystrobin; that is, the highest cross-reactivity to other pesticides observed was 5.7%. The limits of detection of the immunoassays were similar at 3 (ELISA), 46 (FP), and 28 (TR-FIA) pg/mL, as were the respective IC50 values of 306, 252, and 244 pg/mL. Each of the three immunoassays developed was less labor-intensive and approximately 100-fold more sensitive than the gas chromatographic method. While the three formats were comparable in terms of performance, the fluorescence polarization assay was the least labor-intensive and required the least time to perform.

  1. Development of an immunoassay for determination of 2,4-dichlorophenoxyacetic acid (2,4-D) based upon the recombinant Fab fragment of 2,4-D specific antibody

    NASA Astrophysics Data System (ADS)

    Nguyen, Van C.; Nguyen, Thi D. T.; Dau, Hung A.; Tham, Thu N.; Quyen, Dinh T.; Bachmman, Till; Schmid, Rolf D.

    2001-09-01

    To develop an immunoassay and further an immunosensor for 2,4-D based upon recombinant antibody, the Fab fragments of 2,4-D specific antibody were expressed in E. coli. Western blotting analysis of the periplasmic cell fractions shown that under the non-reducing condition only a single protein band at a molecular mass of 45-kDa, corresponding to the whole Fab fragment was detected. Antigen binding activity for 2,4-D was found only in the extract of cells bearing the 2,4-D plasmid. An immunoassay based on the competitive reaction of 2,4-D and enzyme tracer with 2,4-D Fab fragments immobilized on micro titer plates via rabbit anti-mouse IgC was developed. Using this assay, 2,4-D could be detected at concentration range of 0.5 (mu) g/1 to 10(mu) g/1. The center point of the 2,4-D test was found at a concentration of 5 (mu) g/l. The assay was applied for detection of 2,4-D in spiked orange samples, resulting in recovery rate of 90 percent. The immunoassay could be applied to monitor human exposure to 2,4-D from contamination in fruit samples.

  2. A highly sensitive and selective immunoassay for the detection of tetrabromobisphenol A in soil and sediment

    USDA-ARS?s Scientific Manuscript database

    Tetrabromobisphenol A (TBBPA) is the most widely used brominated flame retardant. A sensitive and selective enzyme-linked immunosorbent assay (ELISA) for the detection of TBBPA was developed. Six haptens (T1-T6) mimicking different structural elements of TBBPA were synthesized and coupled to keyhole...

  3. Broad-specificity immunoassay for O,O-diethyl organophosphorus pesticides: Application of molecular modeling to improve assay sensitivity and study antibody recognition

    USDA-ARS?s Scientific Manuscript database

    A monoclonal antibody (MAb) against 4-(diethoxyphosphorothioyloxy)benzoic acid (hapten 1) was raised and used to develop a broad-specificity competitive indirect enzyme-linked immunosorbent assay (ciELISA) for 14 O,O-diethyl organophosphorus pesticides (OPs). Computer-assisted molecular modeling was...

  4. DETECTION OF NORWALK VIRUS AND OTHER GENOGROUP I HUMAN CALICIVIRUSES BY A MONOCLONAL ANTIBODY, RECOMBINANT ANTIGEN-BASED IMMUNOGLOBULIN M CAPTURE ENZYME IMMUNOASSAY. (R826139)

    EPA Science Inventory

    The perspectives, information and conclusions conveyed in research project abstracts, progress reports, final reports, journal abstracts and journal publications convey the viewpoints of the principal investigator and may not represent the views and policies of ORD and EPA. Concl...

  5. Simultaneous detection of multiple chemical residues in milk using broad-specifity antibodies in a hybrid immunosorbent assay

    USDA-ARS?s Scientific Manuscript database

    The wide array of applications using quantum dots (QDs) for detection of multiple analytes reflects the versatility of the technology. In this study, a novel immunoassay using 2 types of sensors (QDs and an enzyme) were simultaneously used for detecting multiple structurally different low-molecular...

  6. Classical scrapie prions are associated with peripheral blood monocytes and T-lymphocytes from naturally infected sheep

    USDA-ARS?s Scientific Manuscript database

    Classical scrapie is a transmissible spongiform encephalopathy that affects sheep and goats. As detected by enzyme-linked immunoassay, previous studies suggested scrapie prions in the blood of sheep might be associated with B lymphocytes but not with monocytes or T lymphocytes. The association of sc...

  7. Toxicity comparison of chlorinated and brominated dibenzo-p-dioxins and dibenzofurans in industrial source samples by HRGC/HRMS and enzyme immunoassay

    EPA Science Inventory

    Limited information is available on the applicability of polychlorinated dibenzo-p-dioxin/furan (PCDD/F) toxicity assays to their brominated counterparts: polybrominated dibenzo-p-dixoins/furans (PBDDs/Fs). We estimated the toxicity of mixtures of chlorinated, brominated, and mi...

  8. A competitive chemiluminescence enzyme immunoassay method for β-defensin-2 detection in transgenic mice.

    PubMed

    Yang, Xi; Zhou, Tao; Yu, Lei; Tan, Wenwen; Zhou, Rui; Hu, Yonggang

    2015-03-01

    A competitive chemiluminescence enzyme immunoassay (CLEIA) method for porcine β-defensin-2 (pBD-2) detection in transgenic mice was established. Several factors that affect detection, including luminol, p-iodophenol and hydrogen peroxide concentrations, as well as pH, were studied and optimized. The linear range of the proposed method for pBD-2 detection under optimal conditions was 0.05-80 ng/mL with a correlation coefficient of 0.9960. Eleven detections of a 30 ng/mL pBD-2 standard sample were performed. Reproducible results were obtained with a relative standard deviation of 3.94%. The limit of detection of the method for pBD-2 was 3.5 pg/mL (3σ). The proposed method was applied to determine pBD-2 expression levels in the tissues of pBD-2 transgenic mice, and compared with LC-MS/MS and quantitative real-time reverse-transcriptase polymerase chain reaction. This suggests that the CLEIA can be used as a valuable method to detect and quantify pBD-2. Copyright © 2014 John Wiley & Sons, Ltd.

  9. An efficient enzyme immunoassay for glutamate using glutaraldehyde coupling of the hapten to microtiter plates.

    PubMed

    Ordronneau, P; Abdullah, L H; Petrusz, P

    1991-09-13

    In order to coat microtiter plates for enzyme immunoassays (EIAs), amino acids and other haptens are usually coupled to larger protein molecules. The formation of such conjugates is not always reproducible. This may lead to inconsistent hapten-protein stoichiometries, unfavorable orientation of the hapten on the protein and/or well-to-well variation in the concentration of the available hapten. In the assay described here the excitatory amino acid (EAA) Glu is coupled directly to polystyrene microtiter wells with GA. Each step of the assay was tested for maximum efficiency. The resulting EIA with Glu as a competitor gave excellent reproducibility (coefficient of variation = 5.87%), an EC50 of 2.02 X 10(-5) M and a detection limit of 1.26 X 10(-6) M. This EIA method is generally useful for a variety of antisera to amino acids and small peptides and a wide range of competing substances. It can be used to characterize the conformational requirements for antigen binding, to assay for glutamate or to identify compounds with glutamate-like structure in unknown solutions.

  10. Competitive enzyme-linked immunoassay for sialoglycoprotein of edible bird's nest in food and cosmetics.

    PubMed

    Zhang, Shiwei; Lai, Xintian; Liu, Xiaoqing; Li, Yun; Li, Bifang; Huang, Xiuli; Zhang, Qinlei; Chen, Wei; Lin, Lin; Yang, Guowu

    2012-04-11

    The proliferation of fake and inferior edible bird's nest (EBN) products has recently become an increasingly serious concern. To identify and classify EBN products, a competitive enzyme-linked immunoassay (ELISA) was developed to quantitate sialoglycoprotein in EBN used in food and cosmetic applications. The characteristic sialoglycoprotein in EBN was found, extracted, purified, and analyzed. Sialoglycoprotein, considered the main carrier of sialic acid in EBN, consisted of 106 and 128 kDa proteins. A monoclonal antibody that could recognize both proteins was prepared. The heat-treated process did not change the affinity of sialoglycoprotein with the antibody. An optimized ELISA method was established with a cross-reactivity of less than 0.1% and an IC(50) of 3.3 μg/mL. On the basis of different food and cosmetic samples, the limits of detection (LOD) were 10-18 μg/g. Recoveries of fortified samples at levels of 20 and 80 μg/g ranged from 81.5 to 96.5%, respectively. The coefficients of variation were less than 8.0%.

  11. Specific Immunoassays for Placental Alkaline Phosphatase As a Tumor Marker

    PubMed Central

    Stinghen, Sérvio T.; Moura, Juliana F.; Zancanella, Patrícia; Rodrigues, Giovanna A.; Pianovski, Mara A.; Lalli, Enzo; Arnold, Dodie L.; Minozzo, João C.; Callefe, Luis G.; Ribeiro, Raul C.; Figueiredo, Bonald C.

    2006-01-01

    Human placental (hPLAP) and germ cell (PLAP-like) alkaline phosphatases are polymorphic and heat-stable enzymes. This study was designed to develop specific immunoassays for quantifying hPLAP and PLAP-like enzyme activity (EA) in sera of cancer patients, pregnant women, or smokers. Polyclonal sheep anti-hPLAP antibodies were purified by affinity chromatography with whole hPLAP protein (ICA-PLAP assay) or a synthetic peptide (aa 57–71) of hPLAP (ICA-PEP assay); the working range was 0.1–11 U/L and cutoff value was 0.2 U/L EA for nonsmokers. The intra- and interassay coefficients of variation were 3.7%–6.5% (ICA-PLAP assay) and 9.0%–9.9% (ICA-PEP assay). An insignificant cross-reactivity was noted for high levels of unheated intestinal alkaline phosphatase in ICA-PEP assay. A positive correlation between the regression of tumor size and EA was noted in a child with embryonal carcinoma. It can be concluded that ICA-PEP assay is more specific than ICA-PLAP, which is still useful to detect other PLAP/PLAP-like phenotypes. PMID:17489017

  12. Magnetic Electrochemical Sensing Platform for Biomonitoring of Exposure to Organophosphorus Pesticides and Nerve Agents Based on Simultaneous Measurement of Total Enzyme Amount and Enzyme Activity

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Du, Dan; Wang, Jun; Wang, Limin

    We report a new approach for electrochemical quantification of enzymatic inhibition and phosphorylation for biomonitoring of exposure to organophosphorus (OP) pesticides and nerve agents based on a magnetic beads (MBs) immunosensing platform. The principle of this approach is based on the combination of MBs immuno-capture based enzyme activity assay and competitive immunoassay of total amount of enzyme for simultaneous detection of enzyme inhibition and phosphorylation in biological fluids. Butyrylcholinesterase (BChE) was chosen as a model enzyme. In competitive immunoassay, the target total BChE in a sample (mixture of OP-inhibited BChE and active BChE) competes with the BChE modified on themore » MBs to bind to the limited anti-BChE antibody labeled with quantum dots (QDs-anti-BChE), and followed by electrochemical stripping analysis of the bound QDs conjugate on the MBs. This assay shows a linear response over the total BChE concentration range of 0.1~20 nM. Simultaneously, real time BChE activity was measured on an electrochemical carbon nanotube-based sensor coupled with microflow injection system after immuno-capture by MBs-anti-BChE conjugate. Therefore, the formed phosphorylated adduct (OP-BChE) can be estimated by the difference values of the total amount BChE (including active and OP-inhibited) and active BChE from established calibration curves. This approach not only eliminates the difficulty in screening of low-dose OP exposure (less than 20% inhibition of BChE) because of individual variation of BChE values, but also avoids the drawback of the scarce availability of OP-BChE antibody. It is sensitive enough to detect 0.5 nM OP-BChE, which is less than 2% BChE inhibition. This method offers a new method for rapid, accurate, selective and inexpensive quantification of phosphorylated adducts and enzyme inhibition for biomonitoring of OP and nerve agent exposures.« less

  13. Practical colorimeter for direct measurement of microplates in enzyme immunoassay systems.

    PubMed Central

    Clem, T R; Yolken, R H

    1978-01-01

    A colorimeter capable of measuring results of enzyme-linked immunosorbent assay (ELISA) reactions directly in the wells of a microtiter plate is described. This colorimeter proved to be as accurate as a conventional spectrophotometer in assessing ELISA reactions, but had the advantage of not requiring transfer of the specimen to a separate chamber. With this colorimeter, 96 specimens can be read in approximately 5 min. A practical colorimeter such as this can make the use of ELISA tests more feasible for many laboratories. Images PMID:342540

  14. Diffusion of tricarboxylic acid cycle enzymes in the mitochondrial matrix in vivo. Evidence for restricted mobility of a multienzyme complex.

    PubMed

    Haggie, Peter M; Verkman, A S

    2002-10-25

    It has been proposed that enzymes in many metabolic pathways, including the tricarboxylic acid cycle in the mitochondrial matrix, are physically associated to facilitate substrate channeling and overcome diffusive barriers. We have used fluorescence recovery after photobleaching to measure the diffusional mobilities of chimeras consisting of green fluorescent protein (GFP) fused to the C terminus of four tricarboxylic acid cycle enzymes: malate dehydrogenase, citrate synthase, isocitrate dehydrogenase, and succinyl-CoA synthetase. The GFP-enzyme chimeras were localized selectively in the mitochondrial matrix in transfected Chinese hamster ovary (CHO) and COS7 cells. Laser photobleaching using a 0.7-microm diameter spot demonstrated restricted diffusion of the GFP-enzyme chimeras. Interestingly, all four chimeras had similar diffusional characteristics, approximately 45% of each chimera was mobile and had a diffusion coefficient of 4 x 10(-8) cm(2)/s. In contrast, unconjugated GFP in the mitochondrial matrix (targeted using COX8 leader sequence) diffused freely (nearly 100% mobility) with a greater diffusion coefficient of 20 x 10(-8) cm(2)/s. The mobility of the GFP-enzyme chimeras was insensitive to substrate source, ATP depletion, or inhibition of the adenine nucleotide translocase. These results indicate similar mobility characteristics of unrelated tricarboxylic acid cycle enzymes having different sizes and physical properties, providing biophysical evidence for a diffusible multienzyme complex in the mitochondrial matrix.

  15. An MRM-based workflow for absolute quantitation of lysine-acetylated metabolic enzymes in mouse liver.

    PubMed

    Xu, Leilei; Wang, Fang; Xu, Ying; Wang, Yi; Zhang, Cuiping; Qin, Xue; Yu, Hongxiu; Yang, Pengyuan

    2015-12-07

    As a key post-translational modification mechanism, protein acetylation plays critical roles in regulating and/or coordinating cell metabolism. Acetylation is a prevalent modification process in enzymes. Protein acetylation modification occurs in sub-stoichiometric amounts; therefore extracting biologically meaningful information from these acetylation sites requires an adaptable, sensitive, specific, and robust method for their quantification. In this work, we combine immunoassays and multiple reaction monitoring-mass spectrometry (MRM-MS) technology to develop an absolute quantification for acetylation modification. With this hybrid method, we quantified the acetylation level of metabolic enzymes, which could demonstrate the regulatory mechanisms of the studied enzymes. The development of this quantitative workflow is a pivotal step for advancing our knowledge and understanding of the regulatory effects of protein acetylation in physiology and pathophysiology.

  16. Determining inhibition effects of some aromatic compounds on peroxidase enzyme purified from white and red cabbage

    NASA Astrophysics Data System (ADS)

    Öztekin, Aykut; Almaz, Züleyha; Özdemir, Hasan

    2016-04-01

    Peroxidases (E.C.1.11.1.7) catalyze the one electron oxidation of wide range of substrates. They are used in synthesis reaction, removal of peroxide from industrial wastes, clinical biochemistry and immunoassays. In this study, the white cabbage (Brassica Oleracea var. capitata f. alba) and red cabbage (Brassica oleracea L. var. capitata f. rubra) peroxidase enzymes were purified for investigation of inhibitory effect of some aromatic compounds on these enzymes. IC50 values and Ki constants were calculated for the molecules of 6-Amino nicotinic hydrazide, 6-Amino-5-bromo nicotinic hydrazide, 2-Amino-5-hydroxy benzohydrazide, 4-Amino-3-hydroxy benzohydrazide on purified enzymes and inhibition type of these molecules were determined. (This research was supported by Ataturk University. Project Number: BAP-2015/98).

  17. Determining Enzyme Activity by Radial Diffusion

    ERIC Educational Resources Information Center

    Davis, Bill D.

    1977-01-01

    Discusses advantages of radial diffusion assay in determining presence of enzyme and/or rough approximation of amount of enzyme activities. Procedures are included for the preparation of starch-agar plates, and the application and determination of enzyme. Techniques using plant materials (homogenates, tissues, ungerminated embryos, and seedlings)…

  18. Long-term chemiluminescence signal is produced in the course of luminol oxidation catalyzed by enhancer-independent peroxidase purified from Jatropha curcas leaves.

    PubMed

    Duan, Peipei; Cai, Feng; Luo, Yongting; Chen, Yangxi; Zou, Shujuan

    2015-09-01

    Isoenzyme c of horseradish peroxidase (HRP-C) is widely used in enzyme immunoassay combined with chemiluminescence (CL) detection. For this application, HRP-C activity measurement is usually based on luminol oxidation in the presence of hydrogen peroxide (H2O2). However, this catalysis reaction was enhancer dependent. In this study, we demonstrated that Jatropha curcas peroxidase (JcGP1) showed high efficiency in catalyzing luminol oxidation in the presence of H2O2. Compared with HRP-C, the JcGP1-induced reaction was enhancer independent, which made the enzyme-linked immunosorbent assay (ELISA) simpler. In addition, the JcGP1 catalyzed reaction showed a long-term stable CL signal. We optimized the conditions for JcGP1 catalysis and determined the favorable conditions as follows: 50 mM Tris buffer (pH 8.2) containing 10 mM H2 O2, 14 mM luminol and 0.75 M NaCl. The optimum catalysis temperature was 30°C. The detection limit of JcGP1 under optimum condition was 0.2 pM. Long-term stable CL signal combined with enhancer-independent property indicated that JcGP1 might be a valuable candidate peroxidase for clinical diagnosis and enzyme immunoassay with CL detection. Copyright © 2014 John Wiley & Sons, Ltd.

  19. Probe colorimeter for quantitating enzyme-linked immunosorbent assays and other colorimetric assays performed with microplates.

    PubMed Central

    Ackerman, S B; Kelley, E A

    1983-01-01

    The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units. Images PMID:6341399

  20. Probe colorimeter for quantitating enzyme-linked immunosorbent assays and other colorimetric assays performed with microplates.

    PubMed

    Ackerman, S B; Kelley, E A

    1983-03-01

    The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units.

  1. EQCM Immunoassay for Phosphorylated Acetylcholinesterase as a Biomarker for Organophosphate Exposures Based on Selective Zirconia Adsorption and Enzyme-Catalytic Precipitation

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Hua; Wang, Jun; Choi, Daiwon

    2009-03-01

    A zirconia (ZrO2) adsorption-based immunoassay by electrochemical quartz crystal microbalance (EQCM) has been initially developed, aiming at the detection of phosphorylated acetylcholinesterase (AChE) as a potential biomarker for bio-monitoring exposures to organophosphate (OP) pesticides and chemical warfare agents. Hydroxyl-derivatized monolayer was preferably chosen to modify the crystal serving as the template for directing the electro-deposition of ZrO2 film with uniform nanostructures. The resulting ZrO2 film was utilized to selectively capture phosphorylated AChE from the sample media. Horseradish peroxidase (HRP)-labeled anti-AChE antibodies were further employed to recognize the captured phosphorylated protein. Enzyme-catalytic oxidation of the benzidine substrate resulted in the accumulationmore » of insoluble product on the functionalized crystal. Ultrasensitive EQCM quantification by mass-amplified frequency responses as well as rapid qualification by visual color changes of product could be thus achieved. Moreover, 4-chloro-1-naphthol (CN) was comparably studied as an ideal chromogenic substrate for the enzyme-catalytic precipitation. Experimental results show that the developed EQCM technique can allow for the detection of phosphorylated AChE in human plasma. Such an EQCM immunosensing format opens a new door towards the development of simple, sensitive, and field-applicable biosensor for biologically monitoring low-level OP exposures.« less

  2. Development of an efficient signal amplification strategy for label-free enzyme immunoassay using two site-specific biotinylated recombinant proteins.

    PubMed

    Tang, Jin-Bao; Tang, Ying; Yang, Hong-Ming

    2015-02-15

    Constructing a recombinant protein between a reporter enzyme and a detector protein to produce a homogeneous immunological reagent is advantageous over random chemical conjugation. However, the approach hardly recombines multiple enzymes in a difunctional fusion protein, which results in insufficient amplification of the enzymatic signal, thereby limiting its application in further enhancement of analytical signal. In this study, two site-specific biotinylated recombinant proteins, namely, divalent biotinylated alkaline phosphatase (AP) and monovalent biotinylated ZZ domain, were produced by employing the Avitag-BirA system. Through the high streptavidin (SA)-biotin interaction, the divalent biotinylated APs were clustered in the SA-biotin complex and then incorporated with the biotinylated ZZ. This incorporation results in the formation of a functional macromolecule that involves numerous APs, thereby enhancing the enzymatic signal, and in the production of several ZZ molecules for the interaction with immunoglobulin G (IgG) antibody. The advantage of this signal amplification strategy is demonstrated through ELISA, in which the analytical signal was substantially enhanced, with a 32-fold increase in the detection sensitivity compared with the ZZ-AP fusion protein approach. The proposed immunoassay without chemical modification can be an alternative strategy to enhance the analytical signals in various applications involving immunosensors and diagnostic chips, given that the label-free IgG antibody is suitable for the ZZ protein. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Highly sensitive sandwich immunoassay and immunochromatographic test for the detection of Clostridial epsilon toxin in complex matrices.

    PubMed

    Féraudet-Tarisse, Cécile; Mazuet, Christelle; Pauillac, Serge; Krüger, Maren; Lacroux, Caroline; Popoff, Michel R; Dorner, Brigitte G; Andréoletti, Olivier; Plaisance, Marc; Volland, Hervé; Simon, Stéphanie

    2017-01-01

    Epsilon toxin is one of the four major toxins of Clostridium perfringens. It is the third most potent clostridial toxin after botulinum and tetanus toxins and is thus considered as a potential biological weapon classified as category B by the Centers for Disease Control and Prevention (CDC). In the case of a bioterrorist attack, there will be a need for a rapid, sensitive and specific detection method to monitor food and water contamination by this toxin, and for a simple human diagnostic test. We have produced and characterized five monoclonal antibodies against common epitopes of epsilon toxin and prototoxin. Three of them neutralize the cytotoxic effects of epsilon toxin in vitro. With these antibodies, we have developed highly sensitive tests, overnight and 4-h sandwich enzyme immunoassays and an immunochromatographic test performed in 20 min, reaching detection limits of at least 5 pg/mL (0.15 pM), 30 pg/mL (0.9 pM) and 100 pg/mL (3.5 pM) in buffer, respectively. These tests were also evaluated for detection of epsilon toxin in different matrices: milk and tap water for biological threat detection, serum, stool and intestinal content for human or veterinary diagnostic purposes. Detection limits in these complex matrices were at least 5-fold better than those described in the literature (around 1 to 5 ng/mL), reaching 10 to 300 pg/mL using the enzyme immunoassay and 100 to 2000 pg/mL using the immunochromatographic test.

  4. Highly sensitive sandwich immunoassay and immunochromatographic test for the detection of Clostridial epsilon toxin in complex matrices

    PubMed Central

    Mazuet, Christelle; Pauillac, Serge; Krüger, Maren; Lacroux, Caroline; Popoff, Michel R.; Dorner, Brigitte G.; Andréoletti, Olivier; Plaisance, Marc; Volland, Hervé; Simon, Stéphanie

    2017-01-01

    Epsilon toxin is one of the four major toxins of Clostridium perfringens. It is the third most potent clostridial toxin after botulinum and tetanus toxins and is thus considered as a potential biological weapon classified as category B by the Centers for Disease Control and Prevention (CDC). In the case of a bioterrorist attack, there will be a need for a rapid, sensitive and specific detection method to monitor food and water contamination by this toxin, and for a simple human diagnostic test. We have produced and characterized five monoclonal antibodies against common epitopes of epsilon toxin and prototoxin. Three of them neutralize the cytotoxic effects of epsilon toxin in vitro. With these antibodies, we have developed highly sensitive tests, overnight and 4-h sandwich enzyme immunoassays and an immunochromatographic test performed in 20 min, reaching detection limits of at least 5 pg/mL (0.15 pM), 30 pg/mL (0.9 pM) and 100 pg/mL (3.5 pM) in buffer, respectively. These tests were also evaluated for detection of epsilon toxin in different matrices: milk and tap water for biological threat detection, serum, stool and intestinal content for human or veterinary diagnostic purposes. Detection limits in these complex matrices were at least 5-fold better than those described in the literature (around 1 to 5 ng/mL), reaching 10 to 300 pg/mL using the enzyme immunoassay and 100 to 2000 pg/mL using the immunochromatographic test. PMID:28700661

  5. Rapid determination of phenylethanolamine A in biological samples by enzyme-linked immunosorbent assay and lateral-flow immunoassay.

    PubMed

    Li, Xiangmei; Wang, Wenjun; Wang, Limiao; Wang, Qi; Pei, Xingyao; Jiang, Haiyang

    2015-10-01

    Phenylethanolamine A (PA) is a β-adrenergic agonist, which was first used in animal husbandry as a growth promoter in China in 2010. In this study, a monoclonal-antibody (mAb)-based indirect competitive enzyme-linked immunosorbent assay (icELISA) and lateral-flow immunoassay (LFA) for the detection of PA in swine urine and pork were developed. The immunogen was prepared by linking PA hapten with carrier protein via a diazotization method. The IC50 value of the optimized icELISA was 0.44 ng mL(-1). The limits of detection of the icELISA for PA in swine urine and pork were 0.13 ng mL(-1) and 0.39 ng g(-1), respectively. The recoveries of PA from spiked swine urine and pork were in the range 82.0-107.4 % and 81.8-113.3%, respectively, with the coefficients of variation in the range 4.1-16.2% and 1.2-6.3%, respectively. The mAbs had negligible cross reactivity with 10 other β-agonists. In contrast, the LFA had a cut-off level of 5 ng mL(-1) (g) in swine urine and pork, and the results could be achieved within 5 min. Ten blind samples of swine urine were analyzed simultaneously by icELISA, LFA, and ultra-high-performance liquid chromatography-tandem mass spectrometry, and the results of the three methods agreed well. Therefore, the combination of two immunoassays provides an effective and rapid screening method for detection of PA residues in biological samples.

  6. Validation of two new immunoassays for sensative detection of a broad range of shiga toxins

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to evaluate two newly developed commercial assays, Abraxis Stx1 and Stx2 enzyme-linked immunosorbent assays (ELISAs), for their ability to detect Shiga toxin (Stx) produced by Escherichia coli (E. coli). The performance of these two assays were compared to a widely us...

  7. Eastern Equine Encephalomyelitis Virus and Culiseta Melanura Activity at the Patuxent Wildlife Research Center, 1985-90

    DTIC Science & Technology

    1992-09-01

    melanura ( Coq .), and the virus can cause for virus in 1985, 1989 and 1990. Mosquitoes for Snf severe disease or death in horses, game birds viral...prospective field evaluation of an enzyme immunoassay: detection of eastern equine Carpenter. J. W.. (G. G. Clark and D. M. Watts. 199,9

  8. Seroepidemiology of Toxoplasma gondii infection in general population in a Northern Mexican city

    USDA-ARS?s Scientific Manuscript database

    There is a lack of information about the seroepidemiology of T. gondii infection in the general population of Durango City, Mexico. Anti-T. gondii IgG and IgM antibodies were sought in 974 inhabitants in Durango City, Mexico using enzyme-linked immunoassays. In total, 59 (6.1%) of 974 participants (...

  9. Antibodies to Nipah-Like Virus in Bats (Pteropus lylei), Cambodia

    PubMed Central

    Olson, James G.; Rupprecht, Charles; Rollin, Pierre E.; An, Ung Sam; Niezgoda, Michael; Clemins, Travis; Walston, Joe

    2002-01-01

    Serum specimens from fruit bats were obtained at restaurants in Cambodia. We detected antibodies cross-reactive to Nipah virus by enzyme immunoassay in 11 (11.5%) of 96 Lyle’s flying foxes (Pteropus lylei). Our study suggests that viruses closely related to Nipah or Hendra viruses are more widespread in Southeast Asia than previously documented. PMID:12194780

  10. Distinguishing between respiratory syncytial virus subgroups by protein profile analysis.

    PubMed Central

    Walpita, P; Mufson, M A; Stanek, R J; Pfeifer, D; Connor, J D

    1992-01-01

    We subgrouped 75 strains of respiratory syncytial virus by a protein profile method (PPM) which relies on different mobilities of the phosphoprotein in one-dimensional polyacrylamide gel electrophoresis and does not require monoclonal antibodies. When compared with enzyme immunoassay, PPM correctly subgrouped 54 of 56 subgroup A and all 19 subgroup B strains. Images PMID:1572961

  11. Evaluation of the Alexon-Trend ProSpecT Campylobacter Microplate Assay

    PubMed Central

    Tolcin, Rita; LaSalvia, Margaret M.; Kirkley, Barbara A.; Vetter, Emily A.; Cockerill, Franklin R.; Procop, Gary W.

    2000-01-01

    We evaluated stool specimens known to contain or be free of Campylobacter by traditional culture, using the ProSpecT Campylobacter microplate assay (Alexon-Trend, Ramsey, Minn.). This rapid enzyme immunoassay for the detection of Campylobacter-specific antigens demonstrated 96% sensitivity and 99% specificity and is an acceptable alternative method of Campylobacter detection. PMID:11015419

  12. Nanomaterials with enzyme-like characteristics (nanozymes): next-generation artificial enzymes.

    PubMed

    Wei, Hui; Wang, Erkang

    2013-07-21

    Over the past few decades, researchers have established artificial enzymes as highly stable and low-cost alternatives to natural enzymes in a wide range of applications. A variety of materials including cyclodextrins, metal complexes, porphyrins, polymers, dendrimers and biomolecules have been extensively explored to mimic the structures and functions of naturally occurring enzymes. Recently, some nanomaterials have been found to exhibit unexpected enzyme-like activities, and great advances have been made in this area due to the tremendous progress in nano-research and the unique characteristics of nanomaterials. To highlight the progress in the field of nanomaterial-based artificial enzymes (nanozymes), this review discusses various nanomaterials that have been explored to mimic different kinds of enzymes. We cover their kinetics, mechanisms and applications in numerous fields, from biosensing and immunoassays, to stem cell growth and pollutant removal. We also summarize several approaches to tune the activities of nanozymes. Finally, we make comparisons between nanozymes and other catalytic materials (other artificial enzymes, natural enzymes, organic catalysts and nanomaterial-based catalysts) and address the current challenges and future directions (302 references).

  13. Detection of IgA-class circulating immune complexes (CIC) in sera from patients with IgA nephropathy using a solid-phase anti-C3 Facb enzyme immunoassay (EIA).

    PubMed Central

    Yagame, M; Tomino, Y; Miura, M; Tanigaki, T; Suga, T; Nomoto, Y; Sakai, H

    1987-01-01

    The detection of circulating immune complexes (CIC) in sera from patients with IgA nephropathy is described. A solid-phase anti-C3 Facb enzyme immunoassay (EIA) was employed for detection of IgA-, IgG- and IgM-CIC in sera. The C1q-binding enzyme assay was also used for the detection of CIC in sera from these patients and healthy adults. Twenty-two patients with IgA nephropathy, 14 patients with other glomerular diseases and 19 healthy adults were examined by anti-C3 Facb EIA. The levels of IgA-CIC in sera from patients with IgA nephropathy were significantly higher than those in sera from patients with other glomerular diseases and healthy adults. CIC measured by the C1q-binding enzyme assay was detected in some patients with IgA nephropathy. The levels of serum IgA in patients with IgA nephropathy were significantly higher than those in patients with other glomerular diseases and healthy adults. However, there was no significant correlation between the levels of IgA-CIC in sera and those of serum IgA in patients with IgA nephropathy. There was also no significant correlation between the levels of IgA-CIC in sera and the degree of histopathological injuries in the patients. It is concluded that the solid-phase anti-C3 Facb EIA is useful for the detection of IgA-CIC in sera from patients with IgA nephropathy. PMID:3301093

  14. Sandwich-type enzyme immunoassay for big endothelin-I in plasma: concentrations in healthy human subjects unaffected by sex or posture.

    PubMed

    Aubin, P; Le Brun, G; Moldovan, F; Villette, J M; Créminon, C; Dumas, J; Homyrda, L; Soliman, H; Azizi, M; Fiet, J

    1997-01-01

    A sandwich-type enzyme immunoassay has been developed for measuring human big endothelin-1 (big ET-1) in human plasma and supernatant fluids from human cell cultures. Big ET-1 is the precursor of endothelin 1 (ET-1), the most potent vasoconstrictor known. A rabbit antibody raised against the big ET-1 COOH-terminus fragment was used as an immobilized antibody (anti-P16). The Fab' fragment of a monoclonal antibody (1B3) raised against the ET-1 loop fragment was used as the enzyme-labeled antibody, after being coupled to acetylcholinesterase. The lowest detectable value in the assay was 1.2 pg/mL (0.12 pg/well). The assay was highly specific for big ET-1, demonstrating no cross-reactivity with ET-1, <0.4% cross-reactivity with big endothelin-2 (big ET-2), and <0.1% with big endothelin-3 (big ET-3). We used this assay to evaluate the effect of two different postural positions (supine and standing) on plasma big ET-1 concentrations in 11 male and 11 female healthy subjects. Data analysis revealed that neither sex nor body position influenced plasma big ET-1 concentrations. This assay should thus permit the detection of possible variations in plasma concentrations of big ET-1 in certain pathologies and, in association with ET-1 assay, make possible in vitro study of endothelin-converting enzyme activity in cell models. Such studies could clarify the physiological and clinical roles of this family of peptides.

  15. Development of an innovative immunoassay for CP4EPSPS and Cry1AB genetically modified protein detection and quantification.

    PubMed

    Ermolli, M; Prospero, A; Balla, B; Querci, M; Mazzeo, A; Van Den Eede, G

    2006-09-01

    An innovative immunoassay, called enzyme-linked immunoabsorbant assay (ELISA) Reverse, based on a new conformation of the solid phase, was developed. The solid support was expressly designed to be immersed directly in liquid samples to detect the presence of protein targets. Its application is proposed in those cases where a large number of samples have to be screened simultaneously or when the simultaneous detection of different proteins is required. As a first application, a quantitative immunoassay for Cry1AB protein in genetically modified maize was optimized. The method was tested using genetically modified organism concentrations from 0.1 to 2.0%. The limit of detection and limit of quantitation of the method were determined as 0.0056 and 0.0168 (expressed as the percentage of genetically modified organisms content), respectively. A qualitative multiplex assay to assess the presence of two genetically modified proteins simultaneously was also established for the case of the Cry1AB and the CP4EPSPS (5-enolpyruvylshikimate-3-phosphate synthase) present in genetically modified maize and soy, respectively.

  16. Production of monoclonal antibody against clonazepam for immunoassay of benzodiazepine drugs in swine tissues.

    PubMed

    Shan, Wen C; Cui, Ya L; He, Xin; Zhang, Lei; Liu, Jing; Wang, Jian P

    2015-01-01

    The objective of the present study was to produce a generic monoclonal antibody for immunoassay of residues of benzodiazepine drugs in swine tissues. Clonazepam was used to synthesize a hapten that was coupled to bovine serum albumin as an immunogen for the production of monoclonal antibody. Results showed that the obtained monoclonal antibody was able to recognize five benzodiazepine drugs simultaneously (clonazepam, flunitrazepam nitrazepam, diazepam, and oxazepam). The cross-reactivities were in the range of 24-100% and the limits of detection were in the range of 0.2-1.5 ng mL(-1) depending on the drug. Then a competitive indirect enzyme-linked immunosorbent assay was developed to determine the residues of five benzodiazepines in swine tissues (muscle, liver and kidney). The recoveries of five analytes from the fortified blank samples were in the range of 74.5-96.5% with coefficients of variation lower than 16.7%. Therefore, this immunoassay could be used as a rapid and simple method for the screening of residues of five benzodiazepine drugs in animal-derived foods.

  17. Alkaline phosphatase labeled SERS active sandwich immunoassay for detection of Escherichia coli

    NASA Astrophysics Data System (ADS)

    Bozkurt, Akif Goktug; Buyukgoz, Guluzar Gorkem; Soforoglu, Mehmet; Tamer, Ugur; Suludere, Zekiye; Boyaci, Ismail Hakki

    2018-04-01

    In this study, a sandwich immunoassay method utilizing enzymatic activity of alkaline phosphatase (ALP) on 5-bromo-4-chloro-3-indolyl phosphate (BCIP) for Escherichia coli (E. coli) detection was developed using surface enhanced Raman spectroscopy (SERS). For this purpose, spherical magnetic gold coated core-shell nanoparticles (MNPs-Au) and rod shape gold nanoparticles (Au-NRs) were synthesized and modified for immunomagnetic separation (IMS) of E. coli from the solution. In order to specify the developed method to ALP activity, Au-NRs were labeled with this enzyme. After successful construction of the immunoassay, BCIP substrate was added to produce the SERS-active product; 5-bromo-4-chloro-3-indole (BCI). A good linearity (R2 = 0.992) was established between the specific SERS intensity of BCI at 600 cm- 1 and logarithmic E. coli concentration in the range of 1.7 × 101-1.7 × 106 cfu mL- 1. LOD and LOQ values were also calculated and found to be 10 cfu mL- 1 and 30 cfu mL- 1, respectively.

  18. Biomarkers in the Diagnosis and Prognosis of Alzheimer's Disease.

    PubMed

    Schaffer, Cole; Sarad, Nakia; DeCrumpe, Ashton; Goswami, Disha; Herrmann, Sara; Morales, Jose; Patel, Parth; Osborne, Jim

    2015-10-01

    Alzheimer's disease (AD) is a neurodegenerative disease that inhibits cognitive functions and has no cure. This report reviews the current diagnostic standards for AD with an emphasis on early diagnosis using the cerebrospinal fluid (CSF) biomarkers amyloid-beta, t-tau, and p-tau and fluorodeoxyglucose positron emission tomography imaging. Abnormal levels of these CSF biomarkers and decreased cerebral uptake of glucose have recently been used in the early diagnosis of AD in experimental studies. These promising biomarkers can be measured using immunoassays performed in singleplex or multiplex formats. Although presently, there are no Food and Drug Administration-approved in vitro diagnostics (IVDs) for early detection of AD, a multiplex immunoassay measuring a panel of promising AD biomarkers in CSF may be a likely IVD candidate for the clinical AD diagnostic market. Specifically, the INNO-BIA AlzBio3 immunoassay kit, performed using bead arrays on the xMAP Luminex analyzer, allows simultaneous quantification of amyloid-beta, t-tau, and p-tau biomarkers. AD biomarkers can also be screened using enzyme-linked immunosorbent assays that are offered as laboratory-developed tests. © 2014 Society for Laboratory Automation and Screening.

  19. Development of an incurred cornbread model for gluten detection by immunoassays.

    PubMed

    Sharma, Girdhari M; Khuda, Sefat E; Pereira, Marion; Slate, Andrew; Jackson, Lauren S; Pardo, Christopher; Williams, Kristina M; Whitaker, Thomas B

    2013-12-11

    Gluten that is present in food as a result of cross-contact or misbranding can cause severe health concerns to wheat-allergic and celiac patients. Immunoassays, such as enzyme-linked immunosorbent assay (ELISA) and lateral flow device (LFD), are commonly used to detect gluten traces in foods. However, the performance of immunoassays can be affected by non-assay-related factors, such as food matrix and processing conditions. Gluten (0-500 ppm) and wheat flour (20-1000 ppm) incurred cornbread was prepared at different incurred levels and baking conditions (204.4 °C for 20, 27, and 34 min) to study the accuracy and precision of gluten measurement by seven immunoassay kits (three LFD and four ELISA kits). The stability and immunoreactivity of gluten proteins, as measured by western blot using three different antibodies, were not adversely affected by the baking conditions. However, the gluten recovery varied depending upon the ELISA kit and the gluten source used to make the incurred cornbread, affecting the accuracy of gluten quantification (BioKits, 9-77%; Morinaga, 91-137%; R-Biopharm, 61-108%; and Romer Labs, 113-190%). Gluten recovery was reduced with increased baking time for most ELISA kits analyzed. Both the sampling and analytical variance increased with an increase in the gluten incurred level. The predicted analytical coefficient of variation associated with all ELISA kits was below 12% for all incurred levels, indicative of good analytical precision.

  20. Pepsin as a Marker for Pulmonary Aspiration

    PubMed Central

    Metheny, Norma A.; Chang, Yie-Hwa; Ye, Jing Song; Edwards, Sharon J.; Defer, Julie; Dahms, Thomas E.; Stewart, Barbara J.; Stone, Kathleen S.; Clouse, Ray E.

    2008-01-01

    BACKGROUND Although assessment for aspiration of small volumes of gastric contents in tube-fed patients receiving mechanical ventilation is important, available methods for this purpose are not wholly satisfactory. A potential method is immunoassay of tracheal secretions for the gastric enzyme pepsin. OBJECTIVES To determine the frequency with which pepsin in suctioned tracheal secretions from acutely ill, tube-fed patients receiving mechanical ventilation could be detected via an immunoassay. METHODS A convenience sample of 136 specimens of suctioned tracheal secretions was collected from 30 acutely ill, tube-fed adults receiving mechanical ventilation. Multiple samples were obtained from 26 of the 30 patients (range, 2−11 per subject). An immunoassay with rooster polyclonal antibodies to purified human pepsin was used to detect pepsin in the secretions. RESULTS Fourteen specimens tested positive for pepsin. Secretions from 5 patients accounted for the 14 pepsin-positive results. A significant relationship was found between the position of the head of the bed and the presence of pepsin in tracheal secretions (P< .001). Of the 14 pepsin-positive specimens, 13 (92.9%) were obtained from subjects in a flat position. CONCLUSIONS A pepsin immunoassay can be used to detect pepsin in human tracheal secretions. If pepsin in tracheal secretions is considered an indicator of aspiration of gastric contents, aspiration occurred in 5 of the 30 subjects. A flat position is strongly associated with the presence of pepsin in tracheal secretions. PMID:11888127

  1. Surface-Enhanced Raman Scattering (SERS) for Detection in Immunoassays. Applications, fundamentals, and optimization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Driskell, Jeremy Daniel

    2006-08-09

    Immunoassays have been utilized for the detection of biological analytes for several decades. Many formats and detection strategies have been explored, each having unique advantages and disadvantages. More recently, surface-enhanced Raman scattering (SERS) has been introduced as a readout method for immunoassays, and has shown great potential to meet many key analytical figures of merit. This technology is in its infancy and this dissertation explores the diversity of this method as well as the mechanism responsible for surface enhancement. Approaches to reduce assay times are also investigated. Implementing the knowledge gained from these studies will lead to a more sensitivemore » immunoassay requiring less time than its predecessors. This dissertation is organized into six sections. The first section includes a literature review of the previous work that led to this dissertation. A general overview of the different approaches to immunoassays is given, outlining the strengths and weaknesses of each. Included is a detailed review of binding kinetics, which is central for decreasing assay times. Next, the theoretical underpinnings of SERS is reviewed at its current level of understanding. Past work has argued that surface plasmon resonance (SPR) of the enhancing substrate influences the SERS signal; therefore, the SPR of the extrinsic Raman labels (ERLs) utilized in our SERS-based immunoassay is discussed. Four original research chapters follow the Introduction, each presented as separate manuscripts. Chapter 2 modifies a SERS-based immunoassay previously developed in our group, extending it to the low-level detection of viral pathogens and demonstrating its versatility in terms of analyte type, Chapter 3 investigates the influence of ERL size, material composition, and separation distance between the ERLs and capture substrate on the SERS signal. This chapter links SPR with SERS enhancement factors and is consistent with many of the results from theoretical treatments of SPR and SERS. Chapter 4 introduces a novel method of reducing sample incubation time via capture substrate rotation. Moreover, this work led to a method of virus quantification without the use of standards. Chapter 5 extends the methodology developed in Chapter 4 to both the antigen and ERL labeling step to perform assays with improved analytical performance in less time than can be accomplished in diffusion controlled assays. This dissertation concludes with a general summary and speculates on the future of this exciting approach to carrying out immunoassays.« less

  2. A redox-mediated chromogenic reaction and application in immunoassay.

    PubMed

    Yu, Ru-Jia; Ma, Wei; Peng, Mao-Pan; Bai, Zhi-Shan; Long, Yi-Tao

    2016-08-31

    A novel redox-mediated chromogenic reaction was demonstrated based on the reaction between HAuCl4 and 2,2-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid) (ABTS), which generate various color responses from red to green in the resulting solutions. Various redox substance could be used to mediate the reaction and trigger a distinct color response. We established a sensitive hydrogen peroxide colorimetric sensor based on the redox-mediated chromogenic reaction and depicted the application both in detection of enzyme and in an immunoassay. Combining the traditional chromogenic reagent with gold nanoparticles, our assay has the advantage in short response time (within three minutes), high sensitivity (10(-12) g mL(-1) for HBsAg) and stability. Copyright © 2016. Published by Elsevier B.V.

  3. Enzyme immunoassay of Chlamydia in birds.

    PubMed

    Ruppanner, R; Behymer, D E; DeLong, W J; Franti, C E; Schulz, T

    1984-01-01

    Serum samples from 192 free-living birds (27 species) were tested for antibodies against Chlamydia using the enzyme-linked immunosorbent assay (ELISA); 97 (51%) were seropositive. The highest antibody prevalence was among pheasants (96%), ducks (88%), and blackbirds (86%). None of 41 starlings tested were seropositive. The serotesting of 42 confined pheasants indicated 100% exposure to the organism. The ELISA is a sensitive, rapid serologic method that can be of epidemiologic and diagnostic value for detecting exposure to Chlamydia. The ELISA could also be used for mass-screening of pet birds where chlamydiosis may be considered a potential public health hazard.

  4. The role of electrostatic interactions in protease surface diffusion and the consequence for interfacial biocatalysis.

    PubMed

    Feller, Bob E; Kellis, James T; Cascão-Pereira, Luis G; Robertson, Channing R; Frank, Curtis W

    2010-12-21

    This study examines the influence of electrostatic interactions on enzyme surface diffusion and the contribution of diffusion to interfacial biocatalysis. Surface diffusion, adsorption, and reaction were investigated on an immobilized bovine serum albumin (BSA) multilayer substrate over a range of solution ionic strength values. Interfacial charge of the enzyme and substrate surface was maintained by performing the measurements at a fixed pH; therefore, electrostatic interactions were manipulated by changing the ionic strength. The interfacial processes were investigated using a combination of techniques: fluorescence recovery after photobleaching, surface plasmon resonance, and surface plasmon fluorescence spectroscopy. We used an enzyme charge ladder with a net charge ranging from -2 to +4 with respect to the parent to systematically probe the contribution of electrostatics in interfacial enzyme biocatalysis on a charged substrate. The correlation between reaction rate and adsorption was determined for each charge variant within the ladder, each of which displayed a maximum rate at an intermediate surface concentration. Both the maximum reaction rate and adsorption value at which this maximum rate occurs increased in magnitude for the more positive variants. In addition, the specific enzyme activity increased as the level of adsorption decreased, and for the lowest adsorption values, the specific enzyme activity was enhanced compared to the trend at higher surface concentrations. At a fixed level of adsorption, the specific enzyme activity increased with positive enzyme charge; however, this effect offers diminishing returns as the enzyme becomes more highly charged. We examined the effect of electrostatic interactions on surface diffusion. As the binding affinity was reduced by increasing the solution ionic strength, thus weakening electrostatic interaction, the rate of surface diffusion increased considerably. The enhancement in specific activity achieved at the lowest adsorption values is explained by the substantial rise in surface diffusion at high ionic strength due to decreased interactions with the surface. Overall, knowledge of the electrostatic interactions can be used to control surface parameters such as surface concentration and surface diffusion, which intimately correlate with surface biocatalysis. We propose that the maximum reaction rate results from a balance between adsorption and surface diffusion. The above finding suggests enzyme engineering and process design strategies for improving interfacial biocatalysis in industrial, pharmaceutical, and food applications.

  5. Determining inhibition effects of some aromatic compounds on peroxidase enzyme purified from white and red cabbage

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Öztekin, Aykut, E-mail: aoztekin@agri.edu.tr; Agri Ibrahim Cecen University Faculty of Arts and Sciences, Department of Chemistry, 04100-Agri; Almaz, Züleyha, E-mail: zturkoglu-2344@hotmail.com

    2016-04-18

    Peroxidases (E.C.1.11.1.7) catalyze the one electron oxidation of wide range of substrates. They are used in synthesis reaction, removal of peroxide from industrial wastes, clinical biochemistry and immunoassays. In this study, the white cabbage (Brassica Oleracea var. capitata f. alba) and red cabbage (Brassica oleracea L. var. capitata f. rubra) peroxidase enzymes were purified for investigation of inhibitory effect of some aromatic compounds on these enzymes. IC{sub 50} values and Ki constants were calculated for the molecules of 6-Amino nicotinic hydrazide, 6-Amino-5-bromo nicotinic hydrazide, 2-Amino-5-hydroxy benzohydrazide, 4-Amino-3-hydroxy benzohydrazide on purified enzymes and inhibition type of these molecules were determined. (Thismore » research was supported by Ataturk University. Project Number: BAP-2015/98).« less

  6. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2010 CFR

    2010-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  7. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  8. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  9. Development of an Immunoassay and a Sol-Gel-Based Immunoaffinity Cleanup Method for Coplanar PCBs from Soil and Sediment Samples

    EPA Science Inventory

    Two polychlorinated biphenyls (PCB) enzyme linked immunosorbent assays (ELISAs) were developed using goat PCB purified immunoglobulin (IgG) antibodies (Abs). The IgGs exhibited the highest affinity toward PCB-77 (24 ng mL−1) with sensitivities in the range of 6–11 ng m...

  10. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  11. 9 CFR 85.6 - Interstate movement of pseudorabies vaccinate swine, except swine from qualified negative gene...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... enzyme-linked immunosorbent assay (ELISA) or a gpI Particle Concentration Fluorescence Immunoassay (PCFIA... negative; (iv) The date of the gpI ELISA or the gpI PCFIA approved differential pseudorabies test; and (v) The name of the laboratory that conducted the gpI ELISA or the gpI PCFIA approved differential...

  12. A Semester-Long Student-Directed Research Project Involving Enzyme Immunoassay: Appropriate for Immunology, Endocrinology, or Neuroscience Courses

    ERIC Educational Resources Information Center

    Goyette, Sharon Ramos; DeLuca, Jane

    2007-01-01

    The following project aimed at promoting integrated and long-lasting learning is described for an Immunology course, but it may be adapted to other disciplines. Students were asked to develop and carry out a research project to examine the relationship between immune function and stress. The experiments were required to include the assessment of…

  13. Detection of Circulating Paracoccidioides brasiliensis Antigen in Urine of Paracoccidioidomycosis Patients before and during Treatment

    PubMed Central

    Salina, Margarete Aparecida; Shikanai-Yasuda, Maria Aparecida; Mendes, Rinaldo Poncio; Barraviera, Benedito; Mendes Giannini, Maria José Soares

    1998-01-01

    For the diagnosis and follow-up of paracoccidioidomycosis patients undergoing therapy, we evaluated two methods (immunoblotting and competition enzyme immunoassay) for the detection of circulating antigen in urine samples. A complex pattern of reactivity was observed in the immunoblot test. Bands of 70 and 43 kDa were detected more often in urine samples from patients before treatment. The immunoblot method detected gp43 and gp70 separately or concurrently in 11 (91.7%) of 12 patients, whereas the competition enzyme immunoassay detected antigenuria in 9 (75%) of 12 patients. Both tests appeared to be highly specific (100%), considering that neither fraction detectable by immunoblotting was present in urine samples from the control group. gp43 remained present in the urine samples collected during the treatment period, with a significant decrease in reactivity in samples collected during clinical recovery and increased reactivity in samples collected during relapses. Reactivity of some bands was also detected in urine specimens from patients with “apparent cure.” The detection of Paracoccidioides brasiliensis antigens in urine appears to be a promising method for diagnosing infection, for evaluating the efficacy of treatment, and for detecting relapse. PMID:9620407

  14. [Fundamental evaluation of apolipoprotein B-48 by chemiluminescence enzyme immunoassay--identification of apolipoprotein B-48 with immunoblotting].

    PubMed

    Sato, Itsuko; Fujioka, Yoshio; Hayashi, Fujio; Mukai, Masahiko; Kawano, Seiji; Ishikawa, Yuichi; Yamashita, Shizuya; Kumagai, Shunichi

    2007-06-01

    Apolipoprotein B-48 (apo B-48) is a constituent of chylomicrons and chylomicron remnants, and its fasting concentration has been reported to be a marker of postprandial hyperlipidemia, which is thought to be a risk factor of atherosclerosis. We evaluated the serum apo B-48 concentrations by chemiluminescence enzyme immunoassay (CLEIA), which was recently introduced as Lumipulse f fully automated immunosaasy analyzer by Fujirebio Inc (Tokyo, Japan), and performed immunoblotting on agarose gel electrophoresis with anti-apo B-48 antibody. Apo B-48 assay was intra-assay reproducible (CVs: 1.9-3.1%) and inter-assay reproducible (CVs: 2.2-4.4%). The assay range for apo B-48 was from 0.2 to 40.0 microg/ml. The effects of interfering substances such as free/conjugated birirubin, hemoglobin, Intrafat, ascorbic acid and rheumatoid factor were negligible. For storage, it was preferable to freeze, and to avoid frozen-thaw process as much as possible. Anti-apo B-48 antibody was reactive over a wide range from origin to the position of very-low-density lipoproteins in immunoblotting after agarose gel electrophoresis. Apo B-48 measurement by CLEIA was feasible to clinical use for the assessment of lipoprotein metabolism.

  15. Laboratory and epidemiologic evaluation of an enzyme immunoassay for antibodies to HTLV-III

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ward, J.W.; Grindon, A.J.; Feorino, P.M.

    1986-07-18

    The enzyme immunoassays (EIAs) for antibody to human T-cell lymphotropic virus type III (HTLV-III) were rapidly adopted for screening donated blood and plasma. To evaluate the significance of a positive EIA reaction, test performance was examined in a blood bank screening program. Specimens were tested by EIA, Western blot assay, and HTLV-III/lymphadenopathy-associated virus (LAV) culture. The EIA was positive in 0.25% of 67 190 blood donations. Specimens were categorized and 57.3% had low (weak) reactivity, 12.7% had moderate reactivity, and 30.0% had high reactivity. Highly reactive specimens were strongly associated with a positive Western blot or culture (86.7%) in contrastmore » to moderately and weekly reactive specimens (1.9%). Twenty-five of 29 donors interviewed with a highly reactive EIA had risk factors for HTLV-III/LAV infection. Risk factors were not identified for 74 of 75 interviewed donors with specimens of lower reactivity. The minimum calculated specificity was 99.82%. The use of the HTLV-III EIA has virtually eliminated the use of blood and plasma for HTLV-III/LAV infected donors.« less

  16. Detection of soluble antigens of Toxoplasma gondii by a four-layer modification of an enzyme immunoassay.

    PubMed Central

    Turunen, H J

    1983-01-01

    A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of the antigen assay was confirmed by using guinea pig immunoglobulins from preimmunization sera. The sensitivity of the antigen assay was found to be at least 10 ng of antigen protein per ml. The suitability of the method for detecting antigens of T. gondii in different specimens was studied by experimental toxoplasma infection in mice. Antigenic components of T. gondii could be detected in different tissue specimens from infected animals from the first day after infection onwards. Toxoplasma antigen in serum and urine samples from infected mice reached detectable levels on day 2 after infection followed by a linear increase in antigen concentration in succeeding samples. This method might offer a valuable aid for a rapid etiological diagnosis also in human cases of acute toxoplasmosis. PMID:6345574

  17. Enzyme-antibody dual labeled gold nanoparticles probe for ultrasensitive detection of κ-casein in bovine milk samples.

    PubMed

    Li, Y S; Zhou, Y; Meng, X Y; Zhang, Y Y; Liu, J Q; Zhang, Y; Wang, N N; Hu, P; Lu, S Y; Ren, H L; Liu, Z S

    2014-11-15

    A dual labeled probe was synthesized by coating gold nanoparticles (AuNPs) with anti-κ-CN monoclonal antibody (McAb) and horseradish peroxidase (HRP) enzyme on their surface. The McAb was used as detector and HRP was used as label for signal amplification catalytically oxidize the substrate. AuNPs were used as bridges between the McAb and HRP. Based on the probe, an immunoassay was developed for ultrasensitive detection of κ-CN in bovine milk samples. The assay has a linear response range within 4.2-560 ng mL(-1). The limit of detection (LOD) was 4.2 ng mL(-1) which was 10 times lower than that of traditional McAb-HRP based ELISA. The recoveries of κ-CN from three brand bovine milk samples were from 95.8% to 111.0% that had a good correlation (R(2)=0.998) with those obtained by official standard Kjeldahl method. For higher sensitivity and as simple as the traditional ELISA, the developed immunoassay could provide an alternative approach for ultrasensitive detection of κ-CN in bovine milk sample. Copyright © 2014 Elsevier B.V. All rights reserved.

  18. Sensitivity and Specificity of Histoplasma Antigen Detection by Enzyme Immunoassay.

    PubMed

    Cunningham, Lauren; Cook, Audrey; Hanzlicek, Andrew; Harkin, Kenneth; Wheat, Joseph; Goad, Carla; Kirsch, Emily

    2015-01-01

    The objective of this study was to evaluate the sensitivity and specificity of an antigen enzyme immunoassay (EIA) on urine samples for the diagnosis of histoplasmosis in dogs. This retrospective medical records review included canine cases with urine samples submitted for Histoplasma EIA antigen assay between 2007 and 2011 from three veterinary institutions. Cases for which urine samples were submitted for Histoplasma antigen testing were reviewed and compared to the gold standard of finding Histoplasma organisms or an alternative diagnosis on cytology or histopathology. Sensitivity, specificity, negative predictive value, positive predictive value, and the kappa coefficient and associated confidence interval were calculated for the EIA-based Histoplasma antigen assay. Sixty cases met the inclusion criteria. Seventeen cases were considered true positives based on identification of the organism, and 41 cases were considered true negatives with an alternative definitive diagnosis. Two cases were considered false negatives, and there were no false positives. Sensitivity was 89.47% and the negative predictive value was 95.35%. Specificity and the positive predictive value were both 100%. The kappa coefficient was 0.9207 (95% confidence interval, 0.8131-1). The Histoplasma antigen EIA test demonstrated high specificity and sensitivity for the diagnosis of histoplasmosis in dogs.

  19. Automated thermometric enzyme immunoassay of human proinsulin produced by Escherichia coli.

    PubMed

    Birnbaum, S; Bülow, L; Hardy, K; Danielsson, B; Mosbach, K

    1986-10-01

    We have determined and monitored the production and release of human proinsulin by genetically engineered Escherichia coli cells. Several M9 media samples were analyzed sequentially after centrifugation with the aid of a rapid automated flow-through thermometric enzyme-linked immunosorbent assay (TELISA) system. The response time was 7 min after sample injection and a single assay was complete after 13 min. Insulin concentrations in the range of 0.1-50 micrograms/ml could be determined. The TELISA method correlated well with conventional radioimmunoassay determinations. Standard curves were reproducible over a period of several days even when the immobilized antibody column was stored at 25 degrees C in the enzyme thermistor unit. Thus, immediate assay start up was possible.

  20. Novel electrochemical immunoassay for quantitative monitoring of biotoxin using target-responsive cargo release from mesoporous silica nanocontainers.

    PubMed

    Zhang, Bing; Liu, Bingqian; Liao, Jiayao; Chen, Guonan; Tang, Dianping

    2013-10-01

    A novel homogeneous immunoassay protocol was designed for quantitative monitoring of small molecular biotoxin (brevetoxin B, PbTx-2, as a model) by using target-responsive cargo release from polystyrene microsphere-gated mesoporous silica nanocontainer (MSN). Initially, monoclonal mouse anti-PbTx-2 capture antibody was covalently conjugated onto the surface of MSN (mAb-MSN), and the electroactive cargo (methylene blue, MB) was then trapped in the pores of mAb-MSN by using aminated polystyrene microspheres (APSM) based on the electrostatic interaction. Upon addition of target PbTx-2, the positively charged APSM was displaced from the negatively charged mAb-MSN because of the specific antigen-antibody reaction. Thereafter, the molecular gate was opened, and the trapped methylene blue was released from the pores. The released methylene blue could be monitored by using a square wave voltammetry (SWV) in a homemade microelectrochemical detection cell. Under optimal conditions, the SWV peak current increased with the increasing of PbTx-2 concentration in the range from 0.01 to 3.5 ng mL(-1) with a detection limit (LOD) of 6 pg mL(-1) PbTx-2 at the 3Sblank criterion. Intra- and interassay coefficients of variation with identical batches were ≤6% and 9.5%, respectively. The specificity and sample matrix interfering effects were acceptable. The analysis in 12 spiked seafood samples showed good accordance between results obtained by the developed immunoassay and a commercialized enzyme-linked immunosorbent assay (ELISA) method. Importantly, the target-responsive controlled release system-based electrochemical immunoassay (CRECIA) offers a promising scheme for the development of advanced homogeneous immunoassay without the sample separation and washing procedure.

  1. Glycosylases utilize ``stop and go'' motion to locate DNA damage

    NASA Astrophysics Data System (ADS)

    Nelson, Shane

    2015-03-01

    Oxidative damage to DNA results in alterations that are mutagenic or even cytotoxic. Base excision repair is a mechanism that functions to identify and correct these lesions, and is present in organisms ranging from bacteria to humans. DNA glycosylases are the first enzymes in this pathway and function to locate and remove oxidatively damaged bases, and do so utilizing only thermal energy. However, the question remains of how these enzymes locate and recognize a damaged base among millions of undamaged bases. Utilizing fluorescence video microscopy with high spatial and temporal resolution, we have observed a number of different fluorescently labeled glycosylases (including bacterial FPG, NEI, and NTH as well as mammalian MutyH and OGG). These enzymes diffuse along DNA tightropes at approximately 0.01 +/- 0.005 μm2/s with binding lifetimes ranging from one second to several minutes. Chemically induced damage to the DNA substrate causes a ~ 50% reduction in diffusion coefficients and a ~ 400% increase in binding lifetimes, while mutation of the key ``wedge residue'' - which has been shown to be responsible for damage detection - results in a 200% increase in the diffusion coefficient. Utilizing a sliding window approach to measure diffusion coefficients within individual trajectories, we observe that distributions of diffusion coefficients are bimodal, consistent with periods of diffusive motion interspersed with immobile periods. Utilizing a unique chemo-mechanical simulation approach, we demonstrate that the motion of these glycosylases can be explained as free diffusion along the helical pitch of the DNA, punctuated with two different types of pauses: 1) rapid, short-lived pauses as the enzyme rapidly probes DNA bases to interrogate for damage and, 2) less frequent, longer lived pauses that reflect the enzyme bound to and catalytically removing a damaged base. These simulations also indicate that the wedge residue is critical for interrogation and recognition of damage, and thus enzymes missing this residue diffuse faster. Similarly, chemically induced damage increases the frequency with which the enzymes encounter damaged bases, resulting in slower diffusion.

  2. Nanoporous Gold as a Solid Support for Protein Immobilization for the Development of Immunoassays, and for Biomolecular Interaction Studies

    NASA Astrophysics Data System (ADS)

    Pandey, Binod Prasad

    Nanoporous gold (NPG) is a versatile material of high surface area to volume ratio that can be readily modified with self-assembled monolayers of alkanethiols to which biomolecules can be linked. NPG presents new opportunities for the development of immunoassays, and for the development of carbohydrate based assays. This thesis explores the use of NPG as a support for self-assembled monolayers, their linkage to antibody-enzyme conjugates for immunoassay development, and for the study and application of carbohydrate-protein interactions. Direct kinetic electrochemical immunoassays were developed on NPG for prostate specific antigen (PSA) and carcinoembryonic antigen (CEA). The decrease in enzymatic conversion of p-aminophenylphosphate to p-aminophenol, by alkaline phosphatase conjugated to an antibody, due to steric hindrance caused by the presence of antigen on antibody, was observed as a drop in peak current in square-wave voltammetry. Detection limit of these assays was 0.075 ng mL -1 and 0.015 ng mL-1 for PSA and CEA, respectively. Similarly, the linear range of determination of these biomarkers extended up to 30 ng mL-1 and 10 ng mL-1 for PSA and CEA, respectively. Minimal interference was observed using newborn calf serum as a substitute for the human serum matrix. A rapid and sensitive enzyme linked lectinsorbant assay was also developed for the study of glycoprotein-lectin interactions on the NPG surface. Self-assembled monolayers of alkanethiols on NPG were characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Similarly, the applicability of this surface for the formation of carbohydrate monolayers and its application for lectin carbohydrate interactions was also studied. Pure and mixed SAMs of 8-mercaptooctyl β-D-mannopyranoside (αMan-C8-SH) and α-D-Gal-(1→4)-β-D-Gal-(1α)-D-Glc-1-O-mercaptooctane (Gb3-C8-SH) with alkanethiols having varying tail groups were prepared. Binding affinity and binding kinetics of concanavalin A to mannoside and soybean agglutinin to galactose in these SAMs were found to be different on NPG than on flat polycrystalline gold, and was also sensitive to the chemical composition of the modified surfaces.

  3. Evaluation of a competitive enzyme-linked immunosorbent assay for measurements of soluble HLA-G protein.

    PubMed

    Rasmussen, M; Dahl, M; Buus, S; Djurisic, S; Ohlsson, J; Hviid, T V F

    2014-08-01

    The human leukocyte antigen (HLA) class Ib molecule, HLA-G, has gained increased attention because of its assumed important role in immune regulation. The HLA-G protein exists in several soluble isoforms. Most important are the actively secreted HLA-G5 full-length isoform generated by alternative splicing retaining intron 4 with a premature stop codon, and the cleavage of full-length membrane-bound HLA-G1 from the cell surface, so-called soluble HLA-G1 (sHLA-G1). A specific and sensitive immunoassay for measurements of soluble HLA-G is mandatory for conceivable routine testing and research projects. We report a novel method, a competitive immunoassay, for measuring HLA-G5/sHLA-G1 in biological fluids. The sHLA-G immunoassay is based upon a competitive enzyme-linked immunosorbent assay (ELISA) principle. It includes a recombinant sHLA-G1 protein in complex with β2-microglobulin and a peptide as a standard, biotinylated recombinant sHLA-G1 as an indicator, and the MEM-G/9 anti-HLA-G monoclonal antibody (mAb) as the capture antibody. The specificity and sensitivity of the assay were evaluated. Testing with different recombinant HLA class I proteins and different anti-HLA class I mAbs showed that the sHLA-G immunoassay was highly specific. Optimal combinations of competitor sHLA-G1 and capture mAb concentrations were determined. Two versions of the assay were tested. One with a relatively wide dynamic range from 3.1 to 100.0 ng/ml, and another more sensitive version ranging from 1.6 to 12.5 ng/ml. An intra-assay coefficient of variation (CV) of 15.5% at 88 ng/ml and an inter-assay CV of 23.1% at 39 ng/ml were determined. An assay based on the competitive sHLA-G ELISA may be important for measurements of sHLA-G proteins in several conditions: assisted reproduction, organ transplantation, cancer, and certain pregnancy complications, both in research studies and possibly in the future also for clinical routine use. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Development of an enzyme immunoassay for the antibiotic cefquinome and its application for residue determination in cow's milk after therapeutical mastitis treatment.

    PubMed

    Thal, Johannes; Steffen, Monika; Meier, Bianca; Schneider, Elisabeth; Adriany, Ansgar; Usleber, Ewald

    2011-01-01

    The aim of this study was to develop and evaluate an enzyme immunoassay (EIA) for the cephalosporin antibiotic in milk, in combination with a new microbiological test system (brilliant black reduction test, BRT-P). Polyclonal antibodies against cefquinome were produced in rabbits, using cefquinome-keyhole limpet hemocyanine as the immunogen. These antibodies and a cefquinome-glucose oxidase conjugate were used in a competitive indirect EIA. The detection limit for cefquinome in milk was 1.5 ng ml(-1), recoveries were 80-128% at 4-40 ng ml(-1). Cross-reactivities with other cephalosporins/penicillins were all <1%. The EIA was used to determine cefquinome in incurred raw milk, the BRT-P (detection limit ≈ 20 ng ml(-1)) and a receptor assay (ßeta-s.t.a.r., detection limit ≈ 15 ng ml(-1)) were used in parallel. Five lactating cows, suffering from clinical mastitis, were treated with cefquinome by simultaneous intramammary and intramuscular injection. Cefquinome residues (maximum 10-27 μg ml(-1)) were most exclusively found in the udder quarter which was treated intramammary, residue levels in the other three quarters were low (<20 ng ml(-1)). Even in milk from intramammary-dosed quarters, residue levels fell below European Union maximum residue level (MRL, 20 μg kg(-1)) 2 days before the end of the withdrawal period. EIA, BRT-P, and ßeta-s.t.a.r. results showed acceptable agreement for milk samples, but the newly developed EIA is superior in aspects of sensitivity. In conclusion, this is the first one description of immunoassay and microbiological tests capable to determine cefquinome in milk at the MRL in incurred sample material.

  5. Comparative evaluation of the Ridascreen Verotoxin enzyme immunoassay for detection of Shiga-toxin producing strains of Escherichia coli (STEC) from food and other sources.

    PubMed

    Beutin, L; Steinrück, H; Krause, G; Steege, K; Haby, S; Hultsch, G; Appel, B

    2007-03-01

    To evaluate the suitability of the commercially distributed Ridascreen Verotoxin enzyme immunoassay (EIA) for detection of known genetic types of the Vero (Shiga) toxins 1 (Stx1) and 2 (Stx2) families and to determine its relative sensitivity and specificity. The Ridascreen-EIA was compared with the Vero cell assay, a P(1)-glycoprotein receptor EIA and with stx gene-specific PCs for detection of Stx with 43 Shiga toxin-producing strains of Escherichia coli (STEC) reference strains and with 241 test strains. The Ridascreen-EIA detects strains producing Stx1 and variants Stx1c and Stx1d, as well as Stx2 and variants Stx2d1, Stx2d2, Stx2e, Stx2d, Stx2-O118 (Stx2d-ount), Stx2-NV206, Stx2f and Stx2g. The assay showed a relative sensitivity of 95.7% and a relative specificity of 98.7%. Some of the Stx2-O118-, Stx2e- and Stx2g-producing STEC were not detected with the Ridascreen-EIA probably because of low amount of toxin produced by these strains. The Ridascreen-EIA is able to detect all known types of Stx and is applicable for routine screening of bacterial isolates owing to its high specificity. It is less applicable for testing samples where low amounts of Stx are expected, such as mixed cultures and certain Stx2 variants. This study presents a first comprehensive evaluation of the Ridascreen-EIA, a rapid standardized STEC screening test for routine diagnostic laboratories. Data are presented on the type of the spectrum of Stx that are detected with this immunoassay and its advantages and limits for practical use.

  6. Chemiluminescence immunoassay for the rapid and sensitive detection of antibody against porcine parvovirus by using horseradish peroxidase/detection antibody-coated gold nanoparticles as nanoprobes.

    PubMed

    Zhou, Yuan; Zhou, Tao; Zhou, Rui; Hu, Yonggang

    2014-06-01

    A rapid, simple, facile, sensitive and enzyme-amplified chemiluminescence immunoassay (CLIA) method to detect antibodies against porcine parvovirus has been developed. Horseradish peroxidase (HRP) and the detection antibody were simultaneously co-immobilized on the surface of gold nanoparticles using the electrostatic method to form gold nanoparticle-based nanoprobes. This nanoprobe was employed in a sandwich-type CLIA, which enables CL signal readout from enzymatic catalysis and results in signal amplification. The presence of porcine parvovirus infection was determined in porcine parvovirus antibodies by measuring the CL intensity caused by the reaction of HRP-luminol with H2 O2 . Under optimal conditions, the obtained calibration plot for the standard positive serum was approximately linear within the dilution range of 1:80 to 1:5120. The limit of detection for the assay was 1:10,240 (S/N = 3), which is much lower than that typically achieved with an enzyme-linked immunosorbent assay (1:160; S/N = 3). A series of repeatability measurements using 1:320-fold diluted standard positive serum gave reproducible results with a relative standard deviation of 4.9% (n = 11). The ability of the immunosensor to analyze clinical samples was tested on porcine sera. The immunosensor had an efficiency of 90%, a sensitivity of 93.3%, and a specificity of 87.5% relative to the enzyme-linked immunosorbent assay results. Copyright © 2013 John Wiley & Sons, Ltd.

  7. Microarray-integrated optoelectrofluidic immunoassay system

    PubMed Central

    Han, Dongsik

    2016-01-01

    A microarray-based analytical platform has been utilized as a powerful tool in biological assay fields. However, an analyte depletion problem due to the slow mass transport based on molecular diffusion causes low reaction efficiency, resulting in a limitation for practical applications. This paper presents a novel method to improve the efficiency of microarray-based immunoassay via an optically induced electrokinetic phenomenon by integrating an optoelectrofluidic device with a conventional glass slide-based microarray format. A sample droplet was loaded between the microarray slide and the optoelectrofluidic device on which a photoconductive layer was deposited. Under the application of an AC voltage, optically induced AC electroosmotic flows caused by a microarray-patterned light actively enhanced the mass transport of target molecules at the multiple assay spots of the microarray simultaneously, which reduced tedious reaction time from more than 30 min to 10 min. Based on this enhancing effect, a heterogeneous immunoassay with a tiny volume of sample (5 μl) was successfully performed in the microarray-integrated optoelectrofluidic system using immunoglobulin G (IgG) and anti-IgG, resulting in improved efficiency compared to the static environment. Furthermore, the application of multiplex assays was also demonstrated by multiple protein detection. PMID:27190571

  8. Microarray-integrated optoelectrofluidic immunoassay system.

    PubMed

    Han, Dongsik; Park, Je-Kyun

    2016-05-01

    A microarray-based analytical platform has been utilized as a powerful tool in biological assay fields. However, an analyte depletion problem due to the slow mass transport based on molecular diffusion causes low reaction efficiency, resulting in a limitation for practical applications. This paper presents a novel method to improve the efficiency of microarray-based immunoassay via an optically induced electrokinetic phenomenon by integrating an optoelectrofluidic device with a conventional glass slide-based microarray format. A sample droplet was loaded between the microarray slide and the optoelectrofluidic device on which a photoconductive layer was deposited. Under the application of an AC voltage, optically induced AC electroosmotic flows caused by a microarray-patterned light actively enhanced the mass transport of target molecules at the multiple assay spots of the microarray simultaneously, which reduced tedious reaction time from more than 30 min to 10 min. Based on this enhancing effect, a heterogeneous immunoassay with a tiny volume of sample (5 μl) was successfully performed in the microarray-integrated optoelectrofluidic system using immunoglobulin G (IgG) and anti-IgG, resulting in improved efficiency compared to the static environment. Furthermore, the application of multiplex assays was also demonstrated by multiple protein detection.

  9. Colorimetric stack pad immunoassay for bacterial identification.

    PubMed

    Eltzov, Evgeni; Marks, Robert S

    2017-01-15

    A new colorimetric immunoassay concept, utilizing conventional lateral flow membranes (e.g., conjugation, sample, absorption and nitrocellulose), were placed in a different configuration in a stacking manner, where the liquid sample that may contain the analyte diffuses from the bottom to the upper-most layer. The key element of this proprietary technology is a capture layer, where a nitrocellulose membrane is modified with the target analyte of interest, namely in this study target Escherichia coli. During the immunoassay operation, samples contaminated with the target bacteria will conjugate to their corresponding HRP-antibodies laying in wait and the immune-target measurand complex flows by capillarity towards the upper-most layer to generate a colorimetric signal (positive answer) through an enzymatic reaction. In target-free samples, previously immobilized target bacteria on the capture layer will prevent the HRP-labeled anti-target antibodies from migrating to the upper-most layer, where the enzymatic substrate lays in wait. After optimization, the sensitivity of this approach was found to be 1,000 folds higher than ELISAs (10 2 cellsmL -1 ). The advantages of the stacked pad assay include: miniaturization, operational simplicity, fast response time (less than 5min), useful sensitivity. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. A conventional chemical reaction for use in an unconventional assay: A colorimetric immunoassay for aflatoxin B1 by using enzyme-responsive just-in-time generation of a MnO2 based nanocatalyst.

    PubMed

    Lai, Wenqiang; Zeng, Qiao; Tang, Juan; Zhang, Maosheng; Tang, Dianping

    2018-01-10

    The authors describe a colorimetric immunoassay for the model nalyte aflatoxin B 1 (AFB 1 ). It is based on the just-in-time generation of an MnO 2 nanocatalyst. Unlike previously developed immunoassay, the chromogenic reaction relies on the just-in-time formation of an oxidase mimic without the aid of the substrate. Potassium permanganate (KMnO 4 ) is converted into manganese dioxide (MnO 2 ) which acts as an oxidase mimic that catalyzes the oxidation 3,3',5,5'-tetramethylbenzidine (TMB) by oxygen to give a blue colored product. In the presence of ascorbic acid (AA), KMnO 4 is reduced to Mn(II) ions. This results in a decrease in the amount of MnO 2 nanocatalyst. Hence, the oxidation of TMB does not take place. By adding ascorbate oxidase, AA is converted into dehydroascorbic acid which cannot reduce KMnO 4 . Based on these observations, a colorimetric competitive enzyme immunoassay was developed where ascorbate oxidase and gold nanoparticle-labeled antibody against AFB 1 and magnetic beads carrying bovine serum albumin conjugated to AFB 1 are used for the determination of AFB 1 . In presence of AFB 1 , it will compete with the BSA-conjugated AFB 1 (on the magnetic beads) for the labeled antibody against AFB 1 on the gold nanoparticles. This makes the amount of ascorbate oxidase/anti-AFB 1 antibody-labeled gold nanoparticles, which conjugated on magnetic beads, reduce, and resulted in an increase of ascorbic acid. Under optimal conditions, the absorbance (measured at 652 nm) decreases with increasing AFB 1 concentrations in the range from 0.1 to 100 ng mL -1 , with a 0.1 ng mL -1 detection limit (at the 3S blank level). The accuracy of the assay was validated by analyzing spiked peanut samples. The results matched well with those obtained with a commercial ELISA kit. Conceivably, the method is not limited to aflatoxins but has a wide scope in that it may be applied to many other analytes for which respective antibodies are available. Graphical abstract Schematic illustration of ascorbate oxidase (AOx)-mediated potassium permanganate (KMnO 4 )-responsive ascorbic acid (AA) for visual colorimetric immunoassay of aflatoxin B 1 (AFB 1 ) by coupling with hydrolytic reaction of AOx toward AA and the KMnO 4 -Mn(II)-TMB system [note: 3,3',5,5'-tetramethylbenzidine: TMB].

  11. DEVELOPMENT AND EVALUATION OF AN ENZYME-LINKED IMMUNOASSAY (ELISA) METHOD FOR THE MEASUREMENT OF 2,4-DICHLOROPHENOXYACETIC ACID IN HUMAN URINE

    EPA Science Inventory

    This paper describes the development of a 96-microwell high sample capacity ELISA method for measuring 2,4-D in urine; the analysis of 2,4-D in real-world urine samples by both ELISA and GC/MS methods; and compares the ELISA and GC/MS results in several key areas: accuracy, preci...

  12. Erythema migrans and serodiagnosis by enzyme immunoassay and immunoblot with three borrelia species.

    PubMed

    Stanek, G; Breier, F; Menzinger, G; Schaar, B; Hafner, M; Partsch, H

    1999-12-10

    There is wide divergence of opinion between physicians regarding the use of serological measures for the diagnosis and treatment of erythema migrans, the hallmark of Lyme borreliosis. We studied the outcome of an enzyme immunoassay and immunoblot (Western blot) used on the sera of patients who had suffered tick bite and erythema migrans, and had been subsequently treated with various antibiotics. Ninety-nine consecutive patients presenting with erythema migrans after tick bite were prospectively recruited at the outpatient department of two Vienna City hospitals and at the consultation office for Lyme borreliosis of the Institute of Hygiene. University Vienna. Blood samples were taken before antibiotic treatment and 3 and 6 months thereafter. Blood samples from 100 blood donors served as controls. Antibodies against Borrelia burgdorferi sensu lato were determined by enzyme immunoassay (IgG and IgM EIA) and by IgG immunoblot. The latter was performed with isolates of B. alzelii (H2) B. burgdorferi sensu stricto (Le) and B. garinii (W) from Austrian patients. The 4 interpretation criteria for immunoblot results were: A (3 bands out of 8), B (2 bands out of 9), C and D (1 band out of 6). In all patients, the erythema resolved within the treatment period. No complications secondary to the borrelia infection were registered. After treatment there was no significant change in titre, nor was there a difference in the immunoblot pattern between the first, second and third serum samples. Serum antibodies to B. burgdorferi were positive by EIA in 22.9% (IgG) and 2.5% (IgM). Immunoblot results offered by borrelia species and by the interpretation criteria, ranging between 8.3% (criterion A, strain Le) and 44.2% (criterion D, strain H2). By EIA, control samples were IgG and IgM positive in 5% and 1%, respectively. Positive immunoblot results with strain H2 were found in 9%, 13%, 18%, and 20% by the criteria A through D respectively. After antibiotic treatment of erythema migrans the immunological response appears to be abrogated. Thus, serological results are not supportive for the diagnosis of erythema migrans, not will they retrospectively prove successful antibiotic treatment of borrelia infection.

  13. Kinetic study of an enzymic cycling system coupled to an enzymic step: determination of alkaline phosphatase activity.

    PubMed Central

    Valero, E; Varón, R; García-Carmona, F

    1995-01-01

    A kinetic study is made of a system consisting of a specific enzymic cycling assay coupled to an enzymic reaction. A kinetic analysis of this system is presented, and the accumulation of chromophore involved in the cycle is seen to be parabolic, i.e. the rate of the reaction increases continuously with constant acceleration. The system is illustrated by the measurement of alkaline phosphatase activity using beta-NADP+ as substrate. The enzymes alcohol dehydrogenase and diaphorase are used to cycle beta-NAD+ in the presence of ethanol and p-Iodonitrotetrazolium Violet. During each turn of the cycle, one molecule of the tetrazolium salt is reduced to an intensely coloured formazan. A simple procedure for evaluating the kinetic parameters involved in the system and for optimizing this cycling assay is described. The method is applicable to the measurement of any enzyme, and its amplification capacity as well as the simplicity of determining kinetic parameters enable it to be employed in enzyme immunoassays to increase the magnitude of the measured response. PMID:7619054

  14. Effect of Asian and Siberian ginseng on serum digoxin measurement by five digoxin immunoassays. Significant variation in digoxin-like immunoreactivity among commercial ginsengs.

    PubMed

    Dasgupta, Amitava; Wu, Sang; Actor, Jeffrey; Olsen, Margaret; Wells, Alice; Datta, Pradip

    2003-02-01

    Asian and Siberian ginsengs contain glycosides with structural similarities to digoxin. We studied potential interference of ginseng in 5 digoxin immunoassays in 3 Asian (2 liquid extracts, 1 capsule) and 3 Siberian ginseng preparations (1 liquid extract, 2 capsules). With the fluorescence polarization immunoassay (FPIA), we observed apparent digoxin activity in 1 Asian liquid preparation and in the liquid extract and 1 capsule form of Siberian ginseng. In mice fed ginseng, we observed digoxin activities in the serum (Asian, 0.48-0.68 ng/mL [0.6-0.9 nmol/L]; Siberian, 0.20-0.47 ng/mL [0.3-0.6 nmol/L]), indicating that such interferences also occur in vivo. Serum pools prepared from samples from patients receiving digoxin and then supplemented with Asian or Siberian ginseng showed falsely increased digoxin values using the FPIA (e.g., for Asian ginseng, 1.54 ng/mL [2.0 nmol/L] vs control value, 1.10 ng/mL [1.4 nmol/L]) and falsely decreased values using the microparticle enzyme immunoassay (MEIA; 0.73 ng/mL [0.9 nmol/L] vs control value, 1.04 ng/mL [1.3 nmol/L]). Digoxin-like immunoreactive substances (DLISs) showed synergistic effects with ginsengs in interfering with the FPIA and MEIA for digoxin. No interference was observed with 3 other digoxin assays, even in the presence of elevated DLISs.

  15. An organic-inorganic hybrid nanostructure-functionalized electrode for electrochemical immunoassay of biomarker by using magnetic bionanolabels.

    PubMed

    Su, Biling; Tang, Dianping; Tang, Juan; Li, Qunfang; Chen, Guonan

    2011-10-01

    A new electrochemical immunoassay of alpha-fetoprotein (AFP) was developed on an organic-inorganic hybrid nanostructure-functionalized carbon electrode by coupling with magnetic bionanolabels. Multi-walled carbon nanotubes (CNTs), single-stranded DNA, thionine and AFP were utilized for the construction of the immunosensor, while the core-shell Fe(3)O(4)-silver nanocomposites were employed for the label of horseradish peroxidase-anti-AFP conjugates (HRP-anti-AFP-AgFe). Electrochemical measurement toward AFP was carried out by using magnetic bionanolabels as traces and H(2)O(2) as enzyme substrate with a competitive-type immunoassay mode. Experimental results indicated that the immunosensors with carbon nanotubes and DNA exhibited better electrochemical responses than those of without carbon nanotubes or DNA. Under optimal conditions, the electrochemical immunosensor by using HRP-anti-AFP-AgFe as signal antibodies exhibited a linear range of 0.001-200 ng mL(-1) AFP with a low detection limit of 0.5 pg mL(-1) at 3s(B). Both intra- and inter-assay coefficients of variation were 7.3%, 9.4%, 8.7% and 10.2%, 7.8%, 9.4% toward 0.01, 30, 120 ng mL(-1) AFP, respectively. The specificity and stability of the electrochemical immunoassay were acceptable. In addition, the methodology was validated for 12 clinical serum specimens including 9 positive specimens and 3 normal specimens, receiving a good correlation with the results obtained from the referenced electrochemiluminescence assay. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Multiplexed detection of tumor markers with multicolor quantum dots based on fluorescence polarization immunoassay.

    PubMed

    Tian, Jianniao; Zhou, Liujin; Zhao, Yanchun; Wang, Yuan; Peng, Yan; Zhao, Shulin

    2012-04-15

    A multicolor quantum dot (QD)-based nanosensor for multiplex detection of two tumor markers in a homogeneous format based on fluorescence polarization immunoassay was proposed. QDs520 and QDs620 were labeled alpha-fetoprotein(α-AFP) and carcinoembryonic antigen (CEA), respectively. After separated and purified by ultrafiltration, they were used in fluorescence polarization immunoassay for the simultaneous detection of human serum alpha-fetoprotein and carcinoembryonic antigen. Under the optimal conditions, the multi-analyte immunosensor had a wide linear range (from 0.5 ng mL(-1) to 500 ng mL(-1)) for both two tumor markers and good correlation (0.996 for α-AFP and 0.993 for CEA). The detection limits (LOD) were 0.36 ng mL(-1) for CEA and 0.28 ng mL(-1) for α-AFP (S/N=3). The carcinoembryonic antigen and fetoprotein in clinical serum samples were simultaneously detected. The results from 28 serum samples had a good agreement with enzyme-linked immunosorbent assay (ELISA). The relative standard deviation and the recovery suggested that the precision and the accuracy of this analytical method were satisfactory. This strategy with high sensitivity, good specificity, easy procedures and short analysis time shows great promise for clinical diagnoses and basic discovery. The application of QDs with longer fluorescence lifetime and small fluorescence polarization can be used for the determination of high molecular-weight substances which cannot be analyzed using dye fluorescence polarization immunoassay. Copyright © 2012 Elsevier B.V. All rights reserved.

  17. Investigation of hydrazide derivatives inhibitory effect on peroxidase enzyme purified from turnip roots

    NASA Astrophysics Data System (ADS)

    Almaz, Züleyha; Öztekin, Aykut; Özdemir, Hasan

    2017-04-01

    Peroxidases (EC: 1.11.1.7) are haem proteins and contain iron (III) protoporphyrin IX (ferriprotoporphyrin IX) as the prosthetic group [1]. They are found in all cells and play a critical role in many biological processes, such as the host-defense mechanism [2]. Peroxidases (PODs) are widely used in clinical biochemistry, enzyme immunoassays, synthesis of various aromatic chemicals, treatment of waste water containing phenolic compounds [3, 4]. In this study, peroxidase enzyme was purified with Para amino benzohydrazide (PABH)-L-Tyrosine Sepharose 4B affinity chromatography to investigate the inhibitory effect of hydrazide derivatives on Turnip (Brassica rapa L.). IC50 values and Ki constants were calculated for the molecules of 6-Amino nicotinic hydrazide, 6-Amino-5-bromo nicotinic hydrazide, 2-Amino-5-hydroxy benzohydrazide, 4-Amino-3-hydroxy benzohydrazide on purified enzyme and inhibition type of these molecules were determined.

  18. Stabilization of penicillinase-hapten conjugate for enzyme immunoassay.

    PubMed

    Omidfar, K; Rasaee, Mohammad J; Zaraee, Ali B; Amir, M Pour; Rahbarizadeh, F

    2002-01-01

    The influence of various additives, such as organic solvents, polyhydric alcohols, salts, polymers, and cross-linker, on the stability and storage ability of penicillinase-morphine conjugate was studied in liquid and solid (freeze dried) states. The results of these experiments showed that using low concentrations of CaCl2 (0.1-0.2%) could stabilize enzyme activity in both states for more than seven months. The immunoreactivity of antigen toward the antibody did not change significantly. However, a cross-linker such as glutaraldehyde and various additives such as dimethylsulfoxide, glycerol, polyethylene glycol, gelatin, dextran, ammonium sulfate, lactose, and sucrose did not have any effect on stability. In addition, it was found that the presence of lactose and sucrose in the lyophilization procedure gives a significant amount of protection to the enzyme, which could last for a period of seven months and preserve almost 95% of the enzyme activity, as well as immunoreactivity of the tracer molecule.

  19. Chemiluminescence assay for the detection of biological warfare agents

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Langry, K; Horn, J

    A chemiluminescent homogeneous immunoassay and a hand-size multiassay reader are described that could be used for detecting biological materials. The special feature of the assay is that it employs two different antibodies that each bind to a unique epitope on the same antigen. Each group of epitope-specific antibodies has linked to it an enzyme of a proximal-enzyme pair. One enzyme of the pair utilizes a substrate in high concentration to produce a second substrate required by the second enzyme. This new substrate enables the second enzyme to function. The reaction of the second enzyme is configured to produce light. Thismore » chemiluminescence is detected with a charge-coupled device (CCD) camera. The proximal pair enzymes must be in close proximity to one another to allow the second enzyme to react with the product of the first enzyme. This only occurs when the enzyme-linked antibodies are attached to the antigen, whether antigen is a single protein with multiple epitopes or the surface of a cell with a variety of different antigens. As a result of their juxtaposition, the enzymes produce light only in the presence of the biological material. A brief description is given as to how this assay could be utilized in a personal bio-agent detector system.« less

  20. Effects of Chronic Alcohol Exposure on Kainate Receptor-Mediated Neurotransmission in the Hippocampus

    DTIC Science & Technology

    2004-09-01

    hippocampus and hypothalamus. J Neurosci Res 63:200-208. Thorpe GH et al. (1989) Chemiluminescent enzyme immunoassay of alpha - fetoprotein based on an...cells. Proc Natl Acad Sci USA 83:6213-6215. Montpied Pet al. (1991) Prolonged ethanol inhalation decreases gamma-aminobutyric acidA receptor alpha ...potentials mediated via alpha -bungarotoxin-sensitive nico- tinic acetylcholine receptors in rat hippocampal interneurons. J Neurosci 18:8228- 8235

  1. Serological Evidence of Dengue Fever Among Refugees, Hargeysa, Somalia

    DTIC Science & Technology

    1989-01-01

    fever, Sindbis, Chikungunya, yellow HISTORY OF THE DISEASE IN THE fever, and Zika viruses . However, antibody reac- DAM CAMP tive to dengue 2 virus was...fever, Crimean-Congo hemorrhagic fever, Sindbis, Chikungunya, yellow fever, and Zika viruses . However, antibody reactive to dengue 2 virus was detected... ZIKA ) viruses . Further testing of sera for evidence of dengue S Barbera S , MOGAISCIO . viral infection was done by the enzyme immunoassay " (EIA

  2. Hedonic Predictors of Tobacco Dependence: A Puff Guide to Smoking Cessation

    DTIC Science & Technology

    2015-04-07

    process may not always be the case. While Perkins et al. (31) showed the potential for a connection between puff volume, considered reinforcement...effect can be attributed to the effects of "acute tolerance" (31 ). Nicotine is thought to acutely desensitize nicotinic receptors ("acute tolerance...company that performs biological assays) for the cotinine assay. Salivary cotinine levels were measured through an enzyme immunoassay conducted by

  3. Determination of relative assay response factors for toxic chlorinated and brominated dioxins/furans using an enzyme immunoassay (EIA) and a chemically-activated luciferase gene expression cell bioassay (CALUX).

    PubMed

    Samara, Fatin; Gullett, Brian K; Harrison, Robert O; Chu, Andrew; Clark, George C

    2009-04-01

    Determination of toxic activity requires knowledge of both the concentration and toxicity to evaluate the risk for adverse human health and environmental effects. A chemically-activated luciferase gene expression cell bioassay system (CALUX) and an antibody-based method enzyme immunoassay (EIA) were used to detect the dioxin-like response of several polybrominated, polychlorinated, and polybrominated/chlorinated dibenzo-p-dioxins/furans (PBDDs/Fs, PCDDs/Fs, and PBCDDs/Fs, respectively). It has been suggested that the biological activity of the brominated and mixed bromo/chloro compounds is similar to their chlorinated analogues (measured by binding to the Ah receptor). PBDD/F, PCDD/F, and PBCDD/F laboratory standards exhibited biological activity ranging over three orders of magnitude. The highest relative potency (REP) values from CALUX analysis, when compared to 2,3,7,8-TCDD, were 2,3,7,8-TBDD at 0.99 (+/-0.07), 1,2,3,7,8-PeCDD at 0.69, and 2-Br-3,7,8-TriCDD at 0.72 (+/-0.02). Cross-reactivities were calculated using EIA for several PBDDs/Fs and PBCDDs. The highest percent cross-reactivity was found for 2,3,7,8-TBDD at 138 (+/-34%), and 2,3,7-TriBDD at 84 (+/-36%).

  4. Enzyme immunoassay for tenuazonic acid in apple and tomato products.

    PubMed

    Gross, Madeleine; Curtui, Valeriu; Ackermann, Yvonne; Latif, Hadri; Usleber, Ewald

    2011-12-14

    The Alternaria mycotoxin tenuazonic acid was derivatized with succinic anhydride and conjugated to keyhole limpet hemocyanin (KLH) and to horseradish peroxidase (HRP), respectively. The KLH conjugate was used to produce polyclonal antibodies in rabbits. A competitive direct enzyme immunoassay (EIA) for tenuazonic acid was established, which was moderately sensitive for tenuazonic acid [50% inhibition concentration (IC(50)): 320 ± 130 ng/mL] but strongly reacted with tenuazonic acid acetate (IC(50): 23.3 ± 7.5 ng/mL). Therefore, an optimized EIA protocol was established, which employed acetylation of standard and sample extract solutions. The mean standard curve detection limit (IC(30)) for tenuazonic acid acetate was 5.4 ± 2.0 ng/mL, enabling detection limits for tenuazonic acid in apple and tomato products of 25-50 ng/g (150 ng/g in tomato paste). Recoveries in a concentration range of 50-2000 ng/g were 60-130% in apple juice and tomato juice and 40-150% in other tomato products. Tenuazonic acid was detected in apple juice and tomato products from German retail shops at levels of 50-200 ng/g. In conclusion, this novel EIA for tenuazonic acid could be useful within a screening program for Alternaria mycotoxins in food.

  5. Challenges in the Laboratory Diagnosis and Management of Dengue Infections.

    PubMed

    Bhat, Vivek G; Chavan, Preeti; Ojha, Shashank; Nair, Pravin K

    2015-01-01

    Dengue fever is considered the most important arthropod-borne viral diseases in terms of morbidity and mortality. An accurate and efficient diagnosis of dengue plays an important role in case confirmation. The virus may be isolated during the viremic phase (within day 5 of illness), from serum, plasma and peripheral blood mononuclear cells. Enzyme linked immunoassay (ELISA) has demonstrated the presence of high levels of dengue NS1 antigen and tests may be performed by enzyme-immunoassays (EIAs) or immune-chromatographic (ICT) methods. These assays are specific with respect to different flaviviruses. Conventional and real time RT PCR, nested PCR, multiplex PCR and Nucleic acid sequence based amplification (NASBA) have been described as sensitive and relatively rapid method of detecting the virus during the early viremic phase. Other tests used include assay of anti-dengue specific IgM and IgG ELISA. Currently no curative treatment in terms of anti-viral drugs is available for dengue and patients are managed with rest and aggressive supportive therapy. Management may be done at home or in the hospital depending on the severity of the illness. Hospital management includes fluid therapy, blood component transfusion and other modalities of treatments like steroids, recombinant factor VII and management of complications. Various vaccines are in trial stages and may become available in the near future.

  6. Rapid enzyme immunoassay for determination of toxigenicity among clinical isolates of corynebacteria.

    PubMed

    Engler, K H; Efstratiou, A

    2000-04-01

    A rapid enzyme immunoassay (EIA) was developed for the phenotypic detection of diphtheria toxin among clinical isolates of corynebacteria. The assay uses equine polyclonal antitoxin as the capture antibody and an alkaline phosphatase-labeled monoclonal antibody, specific for fragment A of the toxin molecule, as the detecting antibody. The assay is rapid, sensitive, and specific: a final result is available within 3 h of colony selection, and the limits of detection are 0.1 ng of pure diphtheria toxin/ml. Toxigenicity could be detected with isolates grown on a diverse range of culture media, including selective agars. Toxin detection using the EIA was compared to that with the Elek test and PCR detection of fragment A of the diphtheria toxin (tox) gene, using 245 isolates of corynebacteria. The results for the EIA were in complete concordance with those of the Elek test: 87 toxigenic and 158 nontoxigenic isolates. Ten of the phenotypically nontoxigenic strains were found to contain fragment A of the tox gene but did not express the toxin protein. These isolates were found to be nontoxigenic in the Vero cell tissue culture cytotoxicity assay and were therefore nontoxigenic for diagnostic purposes. The EIA is a simple rapid phenotypic test which provides a definitive result on toxigenicity within one working day.

  7. Rapid Enzyme Immunoassay for Determination of Toxigenicity among Clinical Isolates of Corynebacteria

    PubMed Central

    Engler, Kathryn H.; Efstratiou, Androulla

    2000-01-01

    A rapid enzyme immunoassay (EIA) was developed for the phenotypic detection of diphtheria toxin among clinical isolates of corynebacteria. The assay uses equine polyclonal antitoxin as the capture antibody and an alkaline phosphatase-labeled monoclonal antibody, specific for fragment A of the toxin molecule, as the detecting antibody. The assay is rapid, sensitive, and specific: a final result is available within 3 h of colony selection, and the limits of detection are 0.1 ng of pure diphtheria toxin/ml. Toxigenicity could be detected with isolates grown on a diverse range of culture media, including selective agars. Toxin detection using the EIA was compared to that with the Elek test and PCR detection of fragment A of the diphtheria toxin (tox) gene, using 245 isolates of corynebacteria. The results for the EIA were in complete concordance with those of the Elek test: 87 toxigenic and 158 nontoxigenic isolates. Ten of the phenotypically nontoxigenic strains were found to contain fragment A of the tox gene but did not express the toxin protein. These isolates were found to be nontoxigenic in the Vero cell tissue culture cytotoxicity assay and were therefore nontoxigenic for diagnostic purposes. The EIA is a simple rapid phenotypic test which provides a definitive result on toxigenicity within one working day. PMID:10747112

  8. A sensitive chemiluminescence enzyme immunoassay based on molecularly imprinted polymers solid-phase extraction of parathion.

    PubMed

    Chen, Ge; Jin, Maojun; Du, Pengfei; Zhang, Chan; Cui, Xueyan; Zhang, Yudan; She, Yongxin; Shao, Hua; Jin, Fen; Wang, Shanshan; Zheng, Lufei; Wang, Jing

    2017-08-01

    The chemiluminescence enzyme immunoassay (CLEIA) method responds differently to various sample matrices because of the matrix effect. In this work, the CLEIA method was coupled with molecularly imprinted polymers (MIPs) synthesized by precipitation polymerization to study the matrix effect. The sample recoveries ranged from 72.62% to 121.89%, with a relative standard deviation (RSD) of 3.74-18.14%.The ratio of the sample matrix-matched standard curve slope rate to the solvent standard curve slope was 1.21, 1.12, 1.17, and 0.85 for apple, rice, orange and cabbage in samples pretreated with the mixture of PSA and C 18 . However, the ratio of sample (apple, rice, orange, and cabbage) matrix-matched standard-MIPs curve slope rate to the solvent standard curve was 1.05, 0.92, 1.09, and 1.05 in samples pretreated with MIPs, respectively. The results demonstrated that the matrices of the samples greatly interfered with the detection of parathion residues by CLEIA. The MIPs bound specifically to the parathion in the samples and eliminated the matrix interference effect. Therefore, the CLEIA method have successfully applied MIPs in sample pretreatment to eliminate matrix interference effects and provided a new sensitive assay for agro-products. Copyright © 2017 Elsevier Inc. All rights reserved.

  9. Quantitative measurement of human thyroglobulin-specific antibodies by use of a sensitive enzyme-linked immunoassay.

    PubMed

    Kuppers, R C; Outschoorn, I M; Hamilton, R G; Burek, C L; Rose, N R

    1993-04-01

    A quantitative enzyme-linked immunoassay that measures in absolute terms the subclass concentration of human thyroglobulin (huTg)-specific IgG autoantibody was developed. Unique to this study was the use of an affinity-purified anti-huTg standard with a known concentration of the four IgG subclasses. The sensitivity of the ELISA assay was 1-5 ng/ml depending on the IgG subclass being measured. We examined 22 sera of patients with autoimmune thyroid disease. The total huTg-specific antibody concentrations in serum ranged from 0 to nearly 3000 micrograms/ml of IgG. The IgG subclass distribution in individuals with low huTg-specific IgG (< 10 micrograms/ml) was primarily IgG1 and IgG3 Ab. Patients with intermediate levels of huTg IgG (10-600 micrograms/ml) expressed all four subclasses; however, no particular subclass was dominant. Individuals with > 1000 micrograms/ml also showed huTg-Ab in all four subclasses, however, IgG1 and IgG2 were dominant. All four IgG subclasses were used in the response to huTg, although the pattern of usage varied between individuals. There was no dominant subclass usage seen in this patient population.

  10. A magnetic particles-based chemiluminescence enzyme immunoassay for rapid detection of ovalbumin.

    PubMed

    Feng, Xiao-Li; Ren, Hong-Lin; Li, Yan-Song; Hu, Pan; Zhou, Yu; Liu, Zeng-Shan; Yan, Dong-Ming; Hui, Qi; Liu, Dong; Lin, Chao; Liu, Nan-Nan; Liu, Yan-Yan; Lu, Shi-Ying

    2014-08-15

    Egg allergy is an important public health and safety concern, so quantification and administration of food or vaccines containing ovalbumin (OVA) are urgently needed. This study aimed to establish a rapid and sensitive magnetic particles-chemiluminescence enzyme immunoassay (MPs-CLEIA) for the determination of OVA. The proposed method was developed on the basis of a double antibodies sandwich immunoreaction and luminol-H2O2 chemiluminescence system. The MPs served as both the solid phase and separator, the anti-OVA MPs-coated polyclonal antibodies (pAbs) were used as capturing antibody, and the horseradish peroxidase (HRP)-labeled monoclonal antibody (mAb) was taken as detecting antibody. The parameters of the method were evaluated and optimized. The established MPs-CLEIA method had a linear range from 0.31 to 100ng/ml with a detection limit of 0.24ng/ml. The assays showed low reactivities and less than 5% of intraassay and interassay coefficients of variation (CVs), and the average recoveries were between 92 and 97%. Furthermore, the developed method was applied in real samples analysis successfully, and the correlation coefficient with the commercially available OVA kit was 0.9976. Moreover, it was more rapid and sensitive compared with the other methods for testing OVA. Copyright © 2014 Elsevier Inc. All rights reserved.

  11. Immunoassay of paralytic shellfish toxins by moving magnetic particles in a stationary liquid-phase lab-on-a-chip.

    PubMed

    Kim, Myoung-Ho; Choi, Suk-Jung

    2015-04-15

    In this study, we devised a stationary liquid-phase lab-on-a-chip (SLP LOC), which was operated by moving solid-phase magnetic particles in the stationary liquid phase. The SLP LOC consisted of a sample chamber to which a sample and reactants were added, a detection chamber containing enzyme substrate solution, and a narrow channel connecting the two chambers and filled with buffer. As a model system, competitive immunoassays of saxitoxin (STX), a paralytic shellfish toxin, were conducted in the SLP LOC using protein G-coupled magnetic particles (G-MPs) as the solid phase. Anti-STX antibodies, STX-horseradish peroxidase conjugate, G-MPs, and a STX sample were added to the sample chamber and reacted by shaking. While liquids were in the stationary state, G-MPs were transported from the sample chamber to the detection chamber by moving a magnet below the LOC. After incubation to allow the enzymatic reaction to occur, the absorbance of the detection chamber solution was found to be reciprocally related to the STX concentration of the sample. Thus, the SLP LOC may represent a novel, simple format for point-of-care testing applications of enzyme-linked immunosorbent assays by eliminating complicated liquid handling steps. Copyright © 2014 Elsevier B.V. All rights reserved.

  12. Ultrasensitive electrochemical immunoassay of staphylococcal enterotoxin B in food using enzyme-nanosilica-doped carbon nanotubes for signal amplification.

    PubMed

    Tang, Dianping; Tang, Juan; Su, Biling; Chen, Guonan

    2010-10-27

    A new sandwich-type electrochemical immunoassay for ultrasensitive detection of staphylococcal enterotoxin B (SEB) in food was developed using horseradish peroxidase-nanosilica-doped multiwalled carbon nanotubes (HRPSiCNTs) for signal amplification. Rabbit polyclonal anti-SEB antibodies immobilized on the screen-printed carbon electrode (SPCE) and covalently bound to the HRPSiCNTs were used as capture antibodies and detection antibodies, respectively. In the presence of SEB analyte, the sandwich-type immunocomplex could be formed between the immobilized anti-SEB on the SPCE and anti-SEB-labeled HRPSiCNTs, and the carried HRP could catalyze the electrochemical reduction of H2O2 with the help of thionine. The high content of HRP in the HRPSiCNTs could greatly amplify the electrochemical signal. Under optimal conditions, the reduction current increased with the increase of SEB in the sample, and exhibited a dynamic range of 0.05-15 ng/mL with a low detection limit (LOD) of 10 pg/mL SEB (at 3σ). Intra- and interassay coefficients of variation were below 10%. In addition, the assay was evaluated with SEB spiked samples including watermelon juice, soymilk, apple juice, and pork food, receiving excellent correlation with results from commercially available enzyme-linked immunosorbent assay (ELISA).

  13. Competitive Protein-binding assay-based Enzyme-immunoassay Method, Compared to High-pressure Liquid Chromatography, Has a Very Lower Diagnostic Value to Detect Vitamin D Deficiency in 9-12 Years Children.

    PubMed

    Zahedi Rad, Maliheh; Neyestani, Tirang Reza; Nikooyeh, Bahareh; Shariatzadeh, Nastaran; Kalayi, Ali; Khalaji, Niloufar; Gharavi, Azam

    2015-01-01

    The most reliable indicator of Vitamin D status is circulating concentration of 25-hydroxycalciferol (25(OH) D) routinely determined by enzyme-immunoassays (EIA) methods. This study was performed to compare commonly used competitive protein-binding assays (CPBA)-based EIA with the gold standard, high-pressure liquid chromatography (HPLC). Concentrations of 25(OH) D in sera from 257 randomly selected school children aged 9-11 years were determined by two methods of CPBA and HPLC. Mean 25(OH) D concentration was 22 ± 18.8 and 21.9 ± 15.6 nmol/L by CPBA and HPLC, respectively. However, mean 25(OH) D concentrations of the two methods became different after excluding undetectable samples (25.1 ± 18.9 vs. 29 ± 14.5 nmol/L, respectively; P = 0.04). Based on predefined Vitamin D deficiency as 25(OH) D < 12.5 nmol/L, CPBA sensitivity and specificity were 44.2% and 60.6%, respectively, compared to HPLC. In receiver operating characteristic curve analysis, the best cut-offs for CPBA was 5.8 nmol/L, which gave 82% sensitivity, but specificity was 17%. Though CPBA may be used as a screening tool, more reliable methods are needed for diagnostic purposes.

  14. Development of a new rabbit monoclonal antibody and its based competitive indirect enzyme-linked immunosorbent assay for rapid detection of sulfonamides.

    PubMed

    Liu, Na; Han, Zheng; Lu, Lei; Wang, Lin; Ni, Geng; Zhao, Zhihui; Wu, Aibo; Zheng, Xiaodong

    2013-02-01

    Monoclonal antibodies generally obtained through the classic mouse hybridoma system were requisite for the establishment of various immunoassays. In this study, a new rabbit monoclonal antibody (RabMAb) against sulfonamides (SAs) was first produced via hybridoma technique in rabbit. The related enzyme-linked immunosorbent assay (ELISA) was then developed and applied to real sample analysis. A sensitive competitive indirect ELISA method based on a novel RabMAb for rapid detection of sulfonamides was first established. The obtained half-maximum inhibition concentration (IC(50)) values for four SAs were all below 10 ng mL(-1) , with 0.68 ng mL(-1) sulfathiazole (STZ), 1.11 ng mL(-1) sulfadiazine (SD), 1.15 ng mL(-1) sulfapyridine (SP) and 5.27 ng mL(-1) sulfamethoxazole (SMX). Desirable recoveries when detecting different spiked swine urine and milk samples were achieved ranging from 92.6% to 104.3% and from 61.1% to 81.6%, respectively. The proposed immunoassay with the newly developed RabMAb is capable of detection of four SAs (STZ, SD, SP and SMX) with proven satisfactory performance and is applicable for routine large-scale analysis in practical uses. © 2012 Society of Chemical Industry.

  15. A polymerase chain reaction enzyme immunoassay for diagnosing infection caused by Aspergillus fumigatus.

    PubMed Central

    Golbang, N; Burnie, J P; Matthews, R C

    1999-01-01

    AIM: To develop a polymerase chain reaction enzyme immunoassay (PCR-EIA) to measure levels of circulating aspergillus DNA in invasive aspergillosis caused by Aspergillus fumigatus. METHODS: The PCR reaction was based on primers from the 18s rRNA gene. Binding of the product to a streptavidin coated microtitration plate was mediated by a biotinylated capture probe. The product was digoxigenylated during PCR and this was the tag to which antibody was bound in the subsequent EIA. RESULTS: The optical density (OD) endpoint was < 0.1 in 10 sera from neutropenic patients with no evidence of invasive aspergillosis, and in 10 sera from nonneutropenic patients with bacterial pneumonia (group 1). The OD from five of 12 patients with allergic bronchopulmonary aspergillosis (ABPA) (group 2), three with an aspergilloma (group 3), and five with possible invasive aspergillosis (group 4) was > or = 0.1. In 63 sera from 33 cases of proven invasive aspergillosis (group 5) an OD > or = 0.1 was achieved in 48 sera from 30 patients. The maximum OD was 0.510. The level fell in survivors and gradually rose in fatal cases. CONCLUSIONS: This assay validated the concept of diagnosing invasive aspergillosis by measuring levels of circulating fungal DNA in serum. PMID:10562808

  16. The effect of Centella asiatica, vitamins, glycolic acid and their mixtures preparations in stimulating collagen and fibronectin synthesis in cultured human skin fibroblast.

    PubMed

    Hashim, Puziah

    2014-03-01

    Centella asiatica (Linn.) Urban is well known in promoting wound healing and provides significant benefits in skin care and therapeutic products formulation. Glycolic acid and vitamins also play a role in the enhancement of collagen and fibronectin synthesis. Here, we evaluate the specific effect of Centella asiatica (CA), vitamins, glycolic acid and their mixture preparations to stimulate collagen and fibronectin synthesis in cultured human fibroblast cells. The fibroblast cells are incubated with CA, glycolic acid, vitamins and their mixture preparations for 48 h. The cell lysates were analyzed for protein content and collagen synthesis by direct binding enzyme immunoassay. The fibronectin of the cultured supernatant was measured by sandwich enzyme immunoassay. The results showed that CA, glycolic acid, vitamins A, E and C significantly stimulate collagen and fibronectin synthesis in the fibroblast. Addition of glycolic acid and vitamins to CA further increased the levels of collagen and fibronectin synthesis to 8.55 and 23.75 μg/100 μg, respectively. CA, glycolic acid, vitamins A, E, and C, and their mixtures demonstrated stimulatory effect on both extra-cellular matrix synthesis of collagen and fibronectin in in vitro studies on human foreskin fibroblasts, which is beneficial to skin care and therapeutic products formulation.

  17. Ultrasensitive protein detection in blood serum using gold nanoparticle probes by single molecule spectroscopy

    NASA Astrophysics Data System (ADS)

    Chen, Jiji; Wang, Chungang; Irudayaraj, Joseph

    2009-07-01

    A one-step rapid and ultrasensitive immunoassay capable of detecting proteins in blood serum is developed using gold nanoprobes and fluorescence correlation spectroscopy (FCS). In this approach we take advantage of the inherent photoluminescence property of gold nanoparticles (GNPs) to develop a fluorophore-free assay to observe binding entities by monitoring the diffusion of bound versus unbound molecules in a limited confocal volume. 40-nm GNPs conjugated separately with rabbit anti-IgG (Fc) and goat anti-IgG (Fab) when incubated in blood serum containing IgG forms a sandwich structure constituting dimers and oligomers that can be differentiated by to detect IgG in blood serum at a limit of detection (LOD) of 5 pg/ml. The novelty of integrating GNPs with FCS to develop a sensitive blood immunoassay brings single molecule methods one step closer to the clinic.

  18. Development of Fully Automated Low-Cost Immunoassay System for Research Applications.

    PubMed

    Wang, Guochun; Das, Champak; Ledden, Bradley; Sun, Qian; Nguyen, Chien

    2017-10-01

    Enzyme-linked immunosorbent assay (ELISA) automation for routine operation in a small research environment would be very attractive. A portable fully automated low-cost immunoassay system was designed, developed, and evaluated with several protein analytes. It features disposable capillary columns as the reaction sites and uses real-time calibration for improved accuracy. It reduces the overall assay time to less than 75 min with the ability of easy adaptation of new testing targets. The running cost is extremely low due to the nature of automation, as well as reduced material requirements. Details about system configuration, components selection, disposable fabrication, system assembly, and operation are reported. The performance of the system was initially established with a rabbit immunoglobulin G (IgG) assay, and an example of assay adaptation with an interleukin 6 (IL6) assay is shown. This system is ideal for research use, but could work for broader testing applications with further optimization.

  19. Cocaine and opiates use in pregnancy: detection of drugs in neonatal meconium and urine.

    PubMed

    López, P; Bermejo, A M; Tabernero, M J; Cabarcos, P; Alvarez, I; Fernández, P

    2009-09-01

    In this study, the case of a newborn with symptoms of hyperexcitability was analyzed. After it was confirmed in the hospital that the mother had consumed drugs during pregnancy using an enzyme multiplied immunoassay technique, samples of the newborn's urine and meconium were sent to our laboratory to observe the evolution in the distribution of cocaine and opiates during the days following birth. For urine analysis, screening was done with an immunoassay technique, and the confirmation was done by gas chromatography-mass spectrometry (GC-MS) according to a published method. A GC-MS method for simultaneous analysis of cocaine, benzoylecgonine, codeine, morphine, and 6-acetylmorphine in meconium is described. GC-MS confirmation of urine and meconium results showed consumption of cocaine and codeine during pregnancy and also showed the levels of drugs gradually declined, totally disappearing by the third day.

  20. Catechol-chitosan redox capacitor for added amplification in electrochemical immunoanalysis.

    PubMed

    Yan, Kun; Liu, Yi; Guan, Yongguang; Bhokisham, Narendranath; Tsao, Chen-Yu; Kim, Eunkyoung; Shi, Xiao-Wen; Wang, Qin; Bentley, William E; Payne, Gregory F

    2018-05-22

    Antibodies are common recognition elements for molecular detection but often the signals generated by their stoichiometric binding must be amplified to enhance sensitivity. Here, we report that an electrode coated with a catechol-chitosan redox capacitor can amplify the electrochemical signal generated from an alkaline phosphatase (AP) linked immunoassay. Specifically, the AP product p-aminophenol (PAP) undergoes redox-cycling in the redox capacitor to generate amplified oxidation currents. We estimate an 8-fold amplification associated with this redox-cycling in the capacitor (compared to detection by a bare electrode). Importantly, this capacitor-based amplification is generic and can be coupled to existing amplification approaches based on enzyme-linked catalysis or magnetic nanoparticle-based collection/concentration. Thus, the capacitor should enhance sensitivities in conventional immunoassays and also provide chemical to electrical signal transduction for emerging applications in molecular communication. Copyright © 2018 Elsevier B.V. All rights reserved.

  1. Sensitive, fast, and specific immunoassays for methyltestosterone detection.

    PubMed

    Kong, Na; Song, Shanshan; Peng, Juan; Liu, Liqiang; Kuang, Hua; Xu, Chuanlai

    2015-04-29

    An indirect competitive enzyme-linked immunosorbent assay (icELISA) and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT) residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%-100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed.

  2. Development of a highly sensitive and specific immunoassay for enrofloxacin based on heterologous coating haptens.

    PubMed

    Wang, Zhanhui; Zhang, Huiyan; Ni, Hengjia; Zhang, Suxia; Shen, Jianzhong

    2014-04-11

    In the paper, an enzyme-linked immunosorbent immunoassay (ELISA) for detection of enrofloxacin was described using one new derivative of enrofloxacin as coating hapten, resulting in surprisingly high sensitivity and specificity. Incorporation of aminobutyric acid (AA) in the new derivative of enrofloxacin had decreased the IC50 of the ELISA for enrofloxacin from 1.3 μg L(-1) to as low as 0.07 μg L(-1). The assay showed neglect cross-reactivity for other fluoroquinolones but ofloxacin (8.23%), marbofloxacin (8.97%) and pefloxacin (7.29%). Analysis of enrofloxacin fortified chicken muscle showed average recoveries from 81 to 115%. The high sensitivity and specificity of the assay makes it a suitable screening method for the determination of low levels of enrofloxacin in chicken muscle without clean-up step. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. The utility of pre-test clinical scoring for clinical diagnosis of heparin-induced thrombocytopenia in cardiac surgery patients of a tertiary care centre in north India.

    PubMed

    Sachan, D; Gupta, N; Agarwal, P; Chaudhary, R

    2011-08-01

    Heparin-induced thrombocytopenia (HIT) should be diagnosed clinically as well as by laboratory assays for timely recognition, prevention and management of complications. To evaluate the clinical utility of pre-test clinical scoring system in combination with two immunoassays for the diagnosis of HIT in cardiac surgery patients. A total of 100 consecutive patients undergoing cardiac surgery were studied. Pre-test clinical scoring was carried out in patients with thrombocytopenia and further tested by two immunoassays, i.e., Heparin platelet factor 4 (H-PF4) enzyme-linked immunosorbent assay (ELISA) and particle gel immunoassay (PaGIA). Of the 100 patients studied, 42 patients developed thrombocytopenia post-operatively. On pre-test clinical scoring, low T-score was observed in 6 patients, intermediate in 28 and high score in 8 patients, whereas 19 patients (45.2%) were positive by H-PF4 ELISA and 10 (23.8%) by PaGIA for H-PF4 antibody. The difference in the incidence of clinically significant HIT antibodies in the three categories was statistically significant. A good correlation was also observed with ELISA optical density, T-scoring and PaGIA. Pre-test clinical scoring correlates well with the development of H-PF4 antibodies which are incriminated in the causation of thrombotic complications in patients with HIT. We also propose a protocol for diagnosing patients with clinical suspicion of HIT using pre-test clinical scoring and immunoassay. © 2011 The Authors. Transfusion Medicine © 2011 British Blood Transfusion Society.

  4. Survivability of immunoassay reagents exposed to the space radiation environment on board the ESA BIOPAN-6 platform as a prelude to performing immunoassays on Mars.

    PubMed

    Derveni, Mariliza; Allen, Marjorie; Sawakuchi, Gabriel O; Yukihara, Eduardo G; Richter, Lutz; Sims, Mark R; Cullen, David C

    2013-01-01

    The Life Marker Chip (LMC) instrument is an immunoassay-based sensor that will attempt to detect signatures of life in the subsurface of Mars. The molecular reagents at the core of the LMC have no heritage of interplanetary mission use; therefore, the design of such an instrument must take into account a number of risk factors, including the radiation environment that will be encountered during a mission to Mars. To study the effects of space radiation on immunoassay reagents, primarily antibodies, a space study was performed on the European Space Agency's 2007 BIOPAN-6 low-Earth orbit (LEO) space exposure platform to complement a set of ground-based radiation studies. Two antibodies were used in the study, which were lyophilized and packaged in the intended LMC format and loaded into a custom-made sample holder unit that was mounted on the BIOPAN-6 platform. The BIOPAN mission went into LEO for 12 days, after which all samples were recovered and the antibody binding performance was measured via enzyme-linked immunosorbent assays (ELISA). The factors expected to affect antibody performance were the physical conditions of a space mission and the exposure to space conditions, primarily the radiation environment in LEO. Both antibodies survived inactivation by these factors, as concluded from the comparison between the flight samples and a number of shipping and storage controls. This work, in combination with the ground-based radiation tests on representative LMC antibodies, has helped to reduce the risk of using antibodies in a planetary exploration mission context.

  5. Electrical immunosensor based on a submicron-gap interdigitated electrode and gold enhancement.

    PubMed

    Ahn, Junhyoung; Lee, Tae Han; Li, Taihua; Heo, Kwang; Hong, Seunghun; Ko, Jeongheon; Kim, Yongsam; Shin, Yong-Beom; Kim, Min-Gon

    2011-08-15

    We demonstrated that the detection of human interleukin 5 (IL5) with a higher sensitivity than the enzyme-linked immunosorbent assay (ELISA) was possible using mass-producible submicron-gap interdigitated electrodes (IDEs) combined with signal amplification by a gold nanoparticle (AuNP) and gold enhancement. IDEs, facing comb-shape electrodes, can act as simple and miniaturized devices for immunoassay. An IDE with a gap size of 400nm was fabricated by a stepper photolithography process and was applied for the immunoassay of human IL5. A biotinylated anti-human IL5 was immobilized on the streptavidin-modified IDE, and biotin-bovine serum albumin (BSA) and BSA were added sequentially to reduce non-specific binding between the streptavidin-immobilized IDE surface and other proteins. The immunoassay procedure included three main steps: the reaction of human IL5 to form antigen-antibody complexes, the binding of AuNP conjugation with an antibody against human IL5 for the sandwich immunoassay, and gold enhancement for electrical signal amplification. The measurement of electrical current at each step showed that the gold enhancement step was very critical in detection of the concentration of human IL5. Analysis by scanning electron microscope (SEM) showed that close to 1μm particles were formed from 10nm AuNP by the gold enhancement reaction using gold ions and hydroxylamine. Under optimized conditions, human IL5 could be analyzed at 1pgmL(-1) with a wide dynamic range (from 10(-3) to 100ngmL(-1) concentrations). Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Fast and Sensitive Detection of Enteropathogenic Yersinia by Immunoassays

    PubMed Central

    Laporte, Jérôme; Savin, Cyril; Lamourette, Patricia; Devilliers, Karine; Volland, Hervé; Carniel, Elisabeth; Créminon, Christophe

    2014-01-01

    Yersinia enterocolitica and Yersinia pseudotuberculosis, the two Yersinia species that are enteropathogenic for humans, are distributed worldwide and frequently cause diarrhea in inhabitants of temperate and cold countries. Y. enterocolitica is a major cause of foodborne disease resulting from consumption of contaminated pork meat and is further associated with substantial economic cost. However, investigation of enteropathogenic Yersinia species is infrequently performed routinely in clinical laboratories because of their specific growth characteristics, which make difficult their isolation from stool samples. Moreover, current isolation procedures are time-consuming and expensive, thus leading to underestimates of the incidence of enteric yersiniosis, inappropriate prescriptions of antibiotic treatments, and unnecessary appendectomies. The main objective of the study was to develop fast, sensitive, specific, and easy-to-use immunoassays, useful for both human and veterinary diagnosis. Monoclonal antibodies (MAbs) directed against Y. enterocolitica bioserotypes 2/O:9 and 4/O:3 and Y. pseudotuberculosis serotypes I and III were produced. Pairs of MAbs were selected by testing their specificity and affinity for enteropathogenic Yersinia and other commonly found enterobacteria. Pairs of MAbs were selected to develop highly sensitive enzyme immunoassays (EIAs) and lateral flow immunoassays (LFIs or dipsticks) convenient for the purpose of rapid diagnosis. The limit of detection of the EIAs ranged from 3.2 × 103 CFU/ml to 8.8 × 104 CFU/ml for pathogenic serotypes I and III of Y. pseudotuberculosis and pathogenic bioserotypes 2/O:9 and 4/O:3 of Y. enterocolitica and for the LFIs ranged from 105 CFU/ml to 106 CFU/ml. A similar limit of detection was observed for artificially contaminated human feces. PMID:25355759

  7. Antigen based detection of cystic echinococcosis in buffaloes using ELISA and Dot-EIA.

    PubMed

    Sangaran, A; Bino Sundar, S T; Latha, Bhaskaran Ravi

    2017-03-01

    Cystic echinococcosis is caused by the larval stage of the dog tapeworm, Echinococcus granulosus . The disease is recognized as one of the world's major zoonoses affecting human beings and domestic animals apart from its economic and public health importance. Development of the cysts in the intermediate host such as buffaloes occurs in the lungs, liver and other organs. In this study, detection of circulating antigen in the diagnosis of cystic echinococcosis in buffaloes was done using enzyme linked immunosorbent assay and Dot-Enzyme immunoassay (Dot-EIA). The sensitivity and specificity were determined as 89 and 92 % respectively, whereas those of Dot-EIA were determined as 94 and 96 %.

  8. Further Studies on the Lyo and Desmo Components of Several Hydrolytic Enzymes and Their Histochemical Significance

    PubMed Central

    Hannibal, Mark J.; Nachlas, Marvin M.

    1959-01-01

    This report describes additional studies of the lyo and desmo components of esterase, alkaline phosphatase, acid phosphatase, leucine aminopeptidase, and β-glucuronidase. The techniques used have already been reported (7). Enzyme diffusion occurs to different degrees in different fixatives, and varies somewhat with each enzyme. Loss of enzymatic activity during fixation occurs as a result of both inactivation due to the chemical reaction of the fixative with the enzymic protein, and diffusion of the lyo component into the fixative. The amount of diffusion into formalin can be reduced by the addition of salts, sucrose, or methocel. The pH of the aqueous medium significantly influences the removal of the lyo fraction from the tissue section. A striking similarity can be noted in the proportions of each fraction of enzyme present in the kidney of the rat, dog, and man. The procedure of fixation and paraffin embedding of tissue blocks does not wholly prevent the diffusion of the lyo component from the tissue sections when they are subsequently immersed in the aqueous incubation medium. PMID:13654449

  9. Validated low-volume aldosterone immunoassay tailored to GCLP-compliant investigations in small sample volumes.

    PubMed

    Schaefer, J; Burckhardt, B B; Tins, J; Bartel, A; Laeer, S

    2017-12-01

    Heart failure is well investigated in adults, but data in children is lacking. To overcome this shortage of reliable data, appropriate bioanalytical assays are required. Development and validation of a bioanalytical assay for the determination of aldosterone concentrations in small sample volumes applicable to clinical studies under Good Clinical Laboratory Practice. An immunoassay was developed based on a commercially available enzyme-linked immunosorbent assay and validated according to current bioanalytical guidelines of the EMA and FDA. The assay (range 31.3-1000 pg/mL [86.9-2775 pmol/L]) is characterized by a between-run accuracy from - 3.8% to - 0.8% and a between-run imprecision ranging from 4.9% to 8.9% (coefficient of variation). For within-run accuracy, the relative error was between - 11.1% and + 9.0%, while within-run imprecision ranged from 1.2% to 11.8% (CV). For parallelism and dilutional linearity, the relative error of back-calculated concentrations varied from - 14.1% to + 8.4% and from - 7.4% to + 10.5%, respectively. The immunoassay is compliant with the bioanalytical guidelines of the EMA and FDA and allows accurate and precise aldosterone determinations. As the assay can run low-volume samples, it is especially valuable for pediatric investigations.

  10. Profile of Instrumentation Laboratory's HemosIL® AcuStar HIT-Ab(PF4-H) assay for diagnosis of heparin-induced thrombocytopenia.

    PubMed

    Nagler, Michael; Cuker, Adam

    2017-05-01

    Immunoassays play an essential role in the diagnosis of heparin-induced thrombocytopenia (HIT). The objective of this article is to review HemosIL® AcuStar HIT-Ab(PF4-H) (Instrumentation Laboratory, Bedford, MA, USA), a new chemiluminescent immunoassay for HIT. Areas covered: The authors searched the published literature for evaluation studies of HemosIL® AcuStar HIT-Ab(PF4-H) and sought information from the manufacturer. In this paper, the authors discuss the analytical principle and technical aspects of the assay; describe its diagnostic performance in validation studies; report on its reproducibility, cost-effectiveness, and regulatory status; and discuss the implications of the assay on clinical practice and means of integrating it in diagnostic pathways. HemosIL® AcuStar HIT-Ab(PF4-H) is compared with other rapid assays and widely used enzyme-linked immunoassays for the diagnosis of HIT. Expert commentary: HemosIL® AcuStar HIT-Ab(PF4-H) is automatable, can be performed 24 h per day, offers a rapid turnaround time, and appears to have favorable diagnostic accuracy, particularly at thresholds above that listed in the label. These advantages could lead to improved patient outcomes through rapid provision of results at the point of care, enhancing the accuracy of initial diagnosis.

  11. Biological monitoring of 2,4,5-trichlorophenol (I): preparation of antibodies and development of an immunoassay using theoretical models.

    PubMed

    Nichkova, Mikaela; Galve, Roger; Marco, M-Pilar

    2002-11-01

    Antibodies against 2,4,5-trichlorophenol have been prepared after theoretical and molecular modeling chemical studies of three potential immunizing haptens with the aim to find out the one mimicking best the target analyte. Competitive direct and indirect ELISAs have been developed after screening a battery of haptenized enzyme tracers and coating antigens, respectively. The relation between the degree of heterology of the competitor and the resulting immunoassay detectability has been investigated according to the electronic similarities of the competitor haptens with the target analyte taking in consideration their pK(a) values. These studies have been performed using theoretical and molecular modeling tools to find out their electronic distribution at their minimum energetic levels. The results suggest that the competitors should have a high homology to produced assays with good detectability values. On the other hand detectability improves when lowering the hapten density of the competitors. An indirect competitive ELISA has been finally selected for further investigation. The immunoassay has an IC(50) value of 0.6 microg L(-)(1) and a limit of detection of 0.084 microg L(-)(1). The selectivity of the assay is high in relation to other chlorophenols frequently present in real samples. In contrast, the brominated analogues may also be recognized with this assay.

  12. Evolutionary dynamics of enzymes.

    PubMed

    Demetrius, L

    1995-08-01

    This paper codifies and rationalizes the large diversity in reaction rates and substrate specificity of enzymes in terms of a model which postulates that the kinetic properties of present-day enzymes are the consequence of the evolutionary force of mutation and selection acting on a class of primordial enzymes with poor catalytic activity and broad substrate specificity. Enzymes are classified in terms of their thermodynamic parameters, activation enthalpy delta H* and activation entropy delta S*, in their kinetically significant transition states as follows: type 1, delta H* > 0, delta S* < 0; type 2, delta H* < or = 0, delta S* < or = 0; type 3, delta H* > 0, delta S* > 0. We study the evolutionary dynamics of these three classes of enzymes subject to mutation, which acts at the level of the gene which codes for the enzyme and selection, which acts on the organism that contains the enzyme. Our model predicts the following evolutionary trends in the reaction rate and binding specificity for the three classes of molecules. In type 1 enzymes, evolution results in random, non-directional changes in the reaction rate and binding specificity. In type 2 and 3 enzymes, evolution results in a unidirectional increase in both the reaction rate and binding specificity. We exploit these results in order to codify the diversity in functional properties of present-day enzymes. Type 1 molecules will be described by intermediate reaction rates and broad substrate specificity. Type 2 enzymes will be characterized by diffusion-controlled rates and absolute substrate specificity. The type 3 catalysts can be further subdivided in terms of their activation enthalpy into two classes: type 3a (delta H* small) and type 3b (delta H* large). We show that type 3a will be represented by the same functional properties that identify type 2, namely, diffusion-controlled rates and absolute substrate specificity, whereas type 3b will be characterized by non-diffusion-controlled rates and absolute substrate specificity. We infer from this depiction of the three classes of enzymes, a general relation between the two functional properties, reaction rate and substrate specificity, namely, enzymes with diffusion-controlled rates have absolute substrate specificity. By appealing to energetic considerations, we furthermore show that enzymes with diffusion-controlled rates (types 2 and 3a) form a small subset of the class of all enzymes. This codification of present-day enzymes derived from an evolutionary model, essentially relates the structural properties of enzymes, as described by their thermodynamic parameters, to their functional properties, as represented by the reaction rate and substrate specificity.

  13. Anti-brain autoantibodies in the serum of schizophrenic patients: a case-control study.

    PubMed

    Margari, Francesco; Petruzzelli, Maria Giuseppina; Mianulli, Rossana; Toto, Maddalena; Pastore, Adriana; Bizzaro, Nicola; Tampoia, Marilina

    2013-12-30

    Schizophrenia is considered a neurodevelopmental disorder with a multifactorial pathogenesis where autoimmune factors may play a significant role. The aim of this study was to verify the presence of anti-brain autoantibodies in the serum of schizophrenic patients compared to healthy controls. Autoantibodies against brain were detected by the immunofluorescence method, utilizing sections of rat hippocampus and hypothalamus and of monkey cerebellum. Three different fluorescence patterns were observed, staining the nucleus-cytoplasm of neurons, the neuroendothelial of blood vessel and the neurofilaments. Search for other organ-specific and non organ-specific autoantibodies was performed in all sera by indirect immunofluorescence method, enzyme linked immunosorbent assay and chemiluminescence immunoassay. Results showed a significant association between schizophrenia and anti-brain autoantibodies against the neuroendothelium of blood vessel in hypothalamus, hippocampus and cerebellum; a significant nuclear and cytoplasmic staining of neurons was assessed only for the hippocampus. No other significant association was found, except between schizophrenia and anti-nuclear autoantibodies on HEp-2 cells. In conclusion, these results support the hypothesis of a significant association between schizophrenia and circulating anti-brain autoantibodies, suggesting a diffuse reactivity against the neuroendothelium of blood vessel and highlighting a nuclear and cytoplasmic staining of the neurons of hippocampus. © 2013 Published by Elsevier Ireland Ltd.

  14. Depolymerization of starch and pectin using superporous matrix supported enzymes.

    PubMed

    Lali, Arvind; Manudhane, Kushal; Motlekar, Nuzhat; Karandikar, Priti

    2002-08-01

    Immobilized enzyme catalyzed biotransformations involving macromolecular substrates and/or products are greatly retarded due to slow diffusion of large substrate molecules in and out of the typical enzyme supports. Slow diffusion of macromolecules into the matrix pores can be speeded up by use of macroporous supports as enzyme carriers. Depolymerization reactions of polysaccharides like starch, pectin, and dextran to their respective low molecular weight products are some of the reactions that can benefit from use of such superporous matrices. In the present work, an indigenously prepared rigid cross-linked cellulose matrix (called CELBEADS) has been used as support for immobilizing alpha amylase (1,4-alpha-D-glucan glucanohydrolase, EC 3.2.1.1.) and pectinase (endo-PG: poly(1,4-alpha-galactouronide) glycanohydrolase, EC 3.2.1.15). The immobilized enzymes were used for starch and pectin hydrolysis respectively, in batch, packed bed and expanded bed modes. The macroporosity of CELBEADS was found to permit through-flow and easy diffusion of substrates pectin and starch to enzyme sites in the porous supports and gave reaction rates comparable to the rates obtained using soluble enzymes.

  15. Performance of a Limiting-Antigen Avidity Enzyme Immunoassay for Cross-Sectional Estimation of HIV Incidence in the United States

    PubMed Central

    Konikoff, Jacob; Brookmeyer, Ron; Longosz, Andrew F.; Cousins, Matthew M.; Celum, Connie; Buchbinder, Susan P.; Seage, George R.; Kirk, Gregory D.; Moore, Richard D.; Mehta, Shruti H.; Margolick, Joseph B.; Brown, Joelle; Mayer, Kenneth H.; Koblin, Beryl A.; Justman, Jessica E.; Hodder, Sally L.; Quinn, Thomas C.; Eshleman, Susan H.; Laeyendecker, Oliver

    2013-01-01

    Background A limiting antigen avidity enzyme immunoassay (HIV-1 LAg-Avidity assay) was recently developed for cross-sectional HIV incidence estimation. We evaluated the performance of the LAg-Avidity assay alone and in multi-assay algorithms (MAAs) that included other biomarkers. Methods and Findings Performance of testing algorithms was evaluated using 2,282 samples from individuals in the United States collected 1 month to >8 years after HIV seroconversion. The capacity of selected testing algorithms to accurately estimate incidence was evaluated in three longitudinal cohorts. When used in a single-assay format, the LAg-Avidity assay classified some individuals infected >5 years as assay positive and failed to provide reliable incidence estimates in cohorts that included individuals with long-term infections. We evaluated >500,000 testing algorithms, that included the LAg-Avidity assay alone and MAAs with other biomarkers (BED capture immunoassay [BED-CEIA], BioRad-Avidity assay, HIV viral load, CD4 cell count), varying the assays and assay cutoffs. We identified an optimized 2-assay MAA that included the LAg-Avidity and BioRad-Avidity assays, and an optimized 4-assay MAA that included those assays, as well as HIV viral load and CD4 cell count. The two optimized MAAs classified all 845 samples from individuals infected >5 years as MAA negative and estimated incidence within a year of sample collection. These two MAAs produced incidence estimates that were consistent with those from longitudinal follow-up of cohorts. A comparison of the laboratory assay costs of the MAAs was also performed, and we found that the costs associated with the optimal two assay MAA were substantially less than with the four assay MAA. Conclusions The LAg-Avidity assay did not perform well in a single-assay format, regardless of the assay cutoff. MAAs that include the LAg-Avidity and BioRad-Avidity assays, with or without viral load and CD4 cell count, provide accurate incidence estimates. PMID:24386116

  16. Direct analysis of airborne mite allergen (Der f1) in the residential atmosphere by chemifluorescent immunoassay using bioaerosol sampler.

    PubMed

    Miyajima, Kumiko; Suzuki, Yurika; Miki, Daisuke; Arai, Moeka; Arakawa, Takahiro; Shimomura, Hiroji; Shiba, Kiyoko; Mitsubayashi, Kohji

    2014-06-01

    Dermatophagoides farinae allergen (Der f1) is one of the most important indoor allergens associated with allergic diseases in humans. Mite allergen Der f1 is usually associated with particles of high molecular weight; thus, Der f1 is generally present in settled dust. However, a small quantity of Der f1 can be aerosolized and become an airborne component. Until now, a reliable method of detecting airborne Der f1 has not been developed. The aim of this study was to develop a fiber-optic chemifluorescent immunoassay for the detection of airborne Der f1. In this method, the Der f1 concentration measured on the basis of the intensity of fluorescence amplified by an enzymatic reaction between the labeled enzyme by a detection antibody and a fluorescent substrate. The measured Der f1 concentration was in the range from 0.49 to 250 ng/ml and a similar range was found by enzyme-linked immunosorbent assay (ELISA). This method was proved to be highly sensitive to Der f1 compared with other airborne allergens. For the implementation of airborne allergen measurement in a residential environment, a bioaerosol sampler was constructed. The airborne allergen generated by a nebulizer was conveyed to a newly sampler we developed for collecting airborne Der f1. The sampler was composed of polymethyl methacrylate (PMMA) cells for gas/liquid phases and some porous membranes which were sandwiched in between the two phases. Der f1 in air was collected by the sampler and measured using the fiber-optic immunoassay system. The concentration of Der f1 in aerosolized standards was in the range from 0.125 to 2.0 mg/m(3) and the collection rate of the device was approximately 0.2%. © 2013 Elsevier B.V. All rights reserved.

  17. Microchip integrating magnetic nanoparticles for allergy diagnosis.

    PubMed

    Teste, Bruno; Malloggi, Florent; Siaugue, Jean-Michel; Varenne, Anne; Kanoufi, Frederic; Descroix, Stéphanie

    2011-12-21

    We report on the development of a simple and easy to use microchip dedicated to allergy diagnosis. This microchip combines both the advantages of homogeneous immunoassays i.e. species diffusion and heterogeneous immunoassays i.e. easy separation and preconcentration steps. In vitro allergy diagnosis is based on specific Immunoglobulin E (IgE) quantitation, in that way we have developed and integrated magnetic core-shell nanoparticles (MCSNPs) as an IgE capture nanoplatform in a microdevice taking benefit from both their magnetic and colloidal properties. Integrating such immunosupport allows to perform the target analyte (IgE) capture in the colloidal phase thus increasing the analyte capture kinetics since both immunological partners are diffusing during the immune reaction. This colloidal approach improves 1000 times the analyte capture kinetics compared to conventional methods. Moreover, based on the MCSNPs' magnetic properties and on the magnetic chamber we have previously developed the MCSNPs and therefore the target can be confined and preconcentrated within the microdevice prior to the detection step. The MCSNPs preconcentration factor achieved was about 35,000 and allows to reach high sensitivity thus avoiding catalytic amplification during the detection step. The developed microchip offers many advantages: the analytical procedure was fully integrated on-chip, analyses were performed in short assay time (20 min), the sample and reagents consumption was reduced to few microlitres (5 μL) while a low limit of detection can be achieved (about 1 ng mL(-1)).

  18. Enzymes in cleaning products: an overview of toxicological properties and risk assessment/management.

    PubMed

    Basketter, David; Berg, Ninna; Broekhuizen, Cees; Fieldsend, Mark; Kirkwood, Sheila; Kluin, Cornelia; Mathieu, Sophie; Rodriguez, Carlos

    2012-10-01

    Enzymes used in cleaning products have an excellent safety profile, with little ability to cause adverse responses in humans. For acute toxicity, genotoxicity, sub-acute and repeated dose toxicity, enzymes are unremarkable. Reproductive toxicity and carcinogenicity are also not endpoints of concern. Exceptions are the ability of some proteases to produce irritating effects at high concentrations and more importantly, the intrinsic potential of these bacterial/fungal proteins to act as respiratory sensitizers. It is a reasonable assumption that the majority of enzyme proteins possess this hazard. However, methods for characterising the respiratory sensitisation hazard of enzymes are lacking and the information required for risk assessment and risk management, although sufficient, remains limited. Previously, most data was generated in animal models and in in vitro immunoassays that assess immunological cross-reactivity. Nevertheless, by the establishment of strict limits on airborne exposure (based on a defined minimal effect limit of 60ng active enzyme protein/m(3)) and air and health monitoring, occupational safety can be assured. Similarly, by ensuring that airborne exposure is kept similarly low, coupled with knowledge of the fate of these enzymes on skin and fabrics, it has proven possible to establish a long history of safe consumer use of enzyme containing products. Copyright © 2012 Elsevier Inc. All rights reserved.

  19. CDH1 gene polymorphisms, plasma CDH1 levels and risk of gastric cancer in a Chinese population.

    PubMed

    Zhan, Zhen; Wu, Juan; Zhang, Jun-Feng; Yang, Ya-Ping; Tong, Shujuan; Zhang, Chun-Bing; Li, Jin; Yang, Xue-Wen; Dong, Wei

    2012-08-01

    The genetic polymorphisms in E-cadherin gene (CDH1) may affect invasive/metastatic development of gastric cancer by altering gene transcriptional activity of epithelial cell. Our study aims to explore the associations among CDH1 gene polymorphisms, and predisposition of gastric cancer. We genotyped four potentially functional polymorphisms (rs13689, rs1801552, rs16260 and rs17690554) of the CDH1 gene in a case-control study of 387 incident gastric cancer cases and 392 healthy controls by polymerase chain reaction-ligation detection reaction methods (PCR-LDR) and measured the plasma CDH1 levels using enzyme immunoassay among the subjects. The median and inter-quartile range were adopted for representing the mean level of non-normally distributed data, and we found the level of plasma CDH1 in gastric cancer patients (median: 171.00 pg/ml; inter-quartile range: 257.10 pg/ml) were significantly higher than that of controls (median: 137.40 pg/ml; inter-quartile range: 83.90 pg/ml, P = 0.003). However, none of the four polymorphisms or their haplotypes achieved significant differences in their distributions between gastric cancer cases and controls, and interestingly, in the subgroup analysis of gastric cancer, we found that CA genotype of rs26160 and CG genotype of rs17690554 were associated with the risk of diffuse gastric cancer, compared with their wild genotypes (OR = 2.98, 95 % CI: 1.60-5.53; OR = 2.10, 95 % CI: 1.14-3.85, respectively, P < 0.05). In conclusion, our results indicated that plasma CDH1 levels may serve as a risk marker against gastric cancer and variant genotypes of rs26160 and rs17690554 may contribute to the etiology of diffuse gastric cancer in this study. Further studies are warranted to verify these findings.

  20. Does the Alpha-defensin Immunoassay or the Lateral Flow Test Have Better Diagnostic Value for Periprosthetic Joint Infection? A Systematic Review.

    PubMed

    Eriksson, Hannah K; Nordström, Jakob; Gabrysch, Katja; Hailer, Nils P; Lazarinis, Stergios

    2018-05-01

    Measuring alpha-defensin concentrations in synovial fluid may help to diagnose periprosthetic joint infection (PJI). There are two commercially available methods for measuring alpha-defensin in synovial fluid: the enzyme-linked immunosorbent assay-based Synovasure® alpha-defensin immunoassay, which gives a numeric readout within 24 hours, and the Synovasure lateral flow test, which gives a binary readout within 20 minutes. There is no compilation of the existing literature to support the use of one of these two tests over the other. Does the immunoassay or the lateral flow test have better diagnostic value (sensitivity and specificity) in diagnosing PJI? We followed PRISMA guidelines and identified all studies on alpha-defensin concentration in synovial fluid as a PJI diagnostic marker, indexed to April 14, 2017, in PubMed, JSTOR, Google Scholar, and OVID databases. The search retrieved 1578 records. All prospective and retrospective studies on alpha-defensin as a PJI marker (PJI classified according to the criteria of the Musculoskeletal Infection Society) after THA or TKA were included in the analysis. All studies used only one of the two commercially available test methods, but none of them was comparative. After excluding studies with overlapping patient populations, four studies investigating the alpha-defensin immunoassay and three investigating the lateral flow test remained. Alpha-defensin immunoassay studies included 482 joints and lateral flow test studies included 119. The quality of the trials was assessed according to the Quality Assessment of Diagnostic Accuracy Studies (QUADAS-2) tool. The heterogeneity among studies was evaluated by the I index, indicating that the heterogeneity of the included studies was low. Pooled sensitivity, specificity, positive and negative likelihood ratios, and receiver operating curves were calculated for each method and compared with each other. The alpha-defensin immunoassay had superior overall diagnostic value compared with the lateral flow test (area under the curve, 0.98 versus 0.75) with higher sensitivity (96% [90%-98%] versus 71% [55%-83%], p < 0.001), but no difference in specificity with the numbers available (96% [93%-97%] versus 90% [81%-95%], p = 0.060). Measurement of alpha-defensin in synovial fluid is a valuable complement to existing diagnostic criteria, and the immunoassay test detects PJI more accurately than the lateral flow test. The lateral flow test has lower sensitivity, making it difficult to rule out infection, but its relatively high specificity combined with the advantage of a quick response time can make it useful to rule in infection perioperatively. Level III, diagnostic study.

  1. Comparison of the Farr radioimmunoassay, 3 commercial enzyme immunoassays and Crithidia luciliae immunofluorescence test for diagnosis and activity assessment of systemic lupus erythematosus.

    PubMed

    Launay, David; Schmidt, Jean; Lepers, Sébastien; Mirault, Tristan; Lambert, Marc; Kyndt, Xavier; Reumaux, Dominique; Duhamel, Alain; Hachulla, Eric; Hatron, Pierre-Yves; Prin, Lionel; Dubucquoi, Sylvain

    2010-07-04

    Among anti-double-strand (ds)DNA antibody assays, Farr radioimmunoassay is decreasingly used because it requires radioactive material and is labor intensive. We evaluated the performance of Farr, three commercial enzyme immunoassays (EIAs) and the Crithidia luciliae immunofluorescence test (CLIFT) in systemic lupus erythematosus (SLE). Anti-dsDNA antibodies were determined in 99 SLE patients, 101 healthy subjects, and 53 patients with autoimmune rheumatic diseases. Farr performed better than the 3 EIAs and CLIFT for the diagnosis of SLE at the manufacturer's cut off and at the cut off set to achieve a specificity of 95%. To achieve a similar level of specificity, some EIAs had a decrease in sensitivity which was dramatic for some tests. Farr was also the best at distinguishing patients with quiescent to mildly active disease from patients with more active disease at the cut off value of 93 IU/ml. Using manufacturer's cut off did not allow distinguishing between patients with quiescent and active SLE. Farr was the best global test to assess the level of anti-dsDNA antibodies for both diagnosis and disease activity evaluation in SLE with adequately determined cut off values. Some EIA had low performances limiting their use in decision-making regarding diagnosis and/or treatment. Copyright 2010 Elsevier B.V. All rights reserved.

  2. Norwalk virus-associated gastroenteritis traced to ice consumption aboard a cruise ship in Hawaii: comparison and application of molecular method-based assays.

    PubMed Central

    Khan, A S; Moe, C L; Glass, R I; Monroe, S S; Estes, M K; Chapman, L E; Jiang, X; Humphrey, C; Pon, E; Iskander, J K

    1994-01-01

    Investigation of an outbreak of acute nonbacterial gastroenteritis on a cruise ship provided an opportunity to assess new molecular method-based diagnostic methods for Norwalk virus (NV) and the antibody response to NV infection. The outbreak began within 36 h of embarkation and affected 30% of 672 passengers and crew. No single meal, seating, or food item was implicated in the transmission of NV, but a passenger's risk of illness was associated with the amount of ice (but not water) consumed (chi-square for trend, P = 0.009). Of 19 fecal specimens examined, 7 were found to contain 27-nm NV-like particles by electron microscopy and 16 were positive by PCR with very sensitive NV-specific primers, but only 5 were positive by a new highly specific antigen enzyme immunoassay for NV. Ten of 12 serum specimen pairs demonstrated a fourfold or greater rise in antibody titer to recombinant baculovirus-expressed NV antigen. The amplified PCR band shared only 81% nucleotide sequence homology with the reference NV strain, which may explain the lack of utility of the fecal specimen enzyme immunoassay. This report, the first to document the use of these molecular method-based assays for investigation of an outbreak, demonstrates the importance of highly sensitive viral diagnostics such as PCR and serodiagnosis for the epidemiologic investigation of NV gastroenteritis. Images PMID:8150941

  3. Ovine echinococcosis I. Immunological diagnosis by enzyme immunoassay.

    PubMed

    Gatti, Antonio; Alvarez, Angela Rosa; Araya, Daniel; Mancini, Sergio; Herrero, Eduardo; Santillan, Graciela; Larrieu, Edmundo

    2007-01-31

    Immunodiagnosis in sheep presents problems of sensitivity and specificity, limiting its applicability in surveillance systems. The objective of this study was to develop a sensitive, specific and accessible technique for diagnosing cystic echinococcosis in naturally infected sheep and to evaluate the validity of necropsy as a reference test. A total of 247 sheep were studied at slaughterhouses, confirming the parasitological diagnosis with histology. Serum was processed with enzyme immunoassay (EIA) using three antigen preparations: total hydatid liquid (LHT), purified fraction of LHT (S2B) and purified lipoprotein (B). Western Blot (WB) was used as a control. EIA proved effective for differentiating Echinococcus granulosus from larval stage of Taenia hydatigena and intestinal cestodes in all three antigen preparations. Serums from macroscopically negative sheep were reactive to EIA and positive with WB. In the whole flock, sensitivity was 89.2% for LHT, 80.0% for S2B and 86.4% for B. Sensitivity in lambs was 78.6% for LHT, 75.0% for S2B and 64.3% for B. Macroscopic diagnosis at the time of slaughter was found to have limitations as a reference test for immunodiagnosis of cystic equinococcosis in sheep, so it was necessary to include histology and WB as reference tests. LHT was the antigen preparation of greatest value and EIA proved to be a sensitive and specific technique, adequate for surveillance systems and for evaluating control programmes.

  4. Quantitative analysis of the synthesis and secretion of type VII collagen in cultured human dermal fibroblasts with a sensitive sandwich enzyme-linked immunoassay.

    PubMed

    Amano, Satoshi; Ogura, Yuki; Akutsu, Nobuko; Nishiyama, Toshio

    2007-02-01

    Type VII collagen is the major component of anchoring fibrils in the epidermal basement membrane. Its expression has been analyzed by immunostaining or Northern blotting, but rarely at the protein level. In this study, we have quantitatively examined the effects of ascorbic acid and various cytokines/growth factors on the protein synthesis and secretion of type VII collagen by human dermal fibroblasts in culture, using a developed, highly sensitive sandwich enzyme-linked immunoassay with two kinds of specific monoclonal antibodies against the non-collagenous domain-1. Ascorbic acid and its derivative induced a twofold increase in type VII collagen synthesis, and markedly increased the secretion of type VII collagen into the medium when compared with the control culture. This effect was not influenced by the presence of transforming growth factor-beta1 (TGF-beta1). The synthesis of type VII collagen was elevated by TGF-beta1, platelet-derived growth factor, tumor necrosis factor-alpha, and interleukin-1beta, but not by TGF-alpha. Thus, our data indicate that the synthesis and secretion of type VII collagen in human dermal fibroblasts are regulated by ascorbate and the enhancement of type VII collagen gene expression by cytokines/growth factors is accompanied with elevated production of type VII collagen at the protein level.

  5. Evaluation of enzyme immunoassay techniques for diagnosis of the most common intestinal protozoa in fecal samples.

    PubMed

    Gaafar, Maha R

    2011-08-01

    This study was designed to evaluate the antigen capture enzyme immunoassays (EIAs) Triage parasite panel and TechLab Entamoeba histolytica II in detecting Giardia intestinalis, Cryptosporidium sp, and Entamoeba histolytica in fecal samples in comparison to microscopy, and in differentiating Entamoeba histolytica from Entamoeba dispar. The Triage EIA was evaluated using 100 stool specimens that were tested by standard ova and parasite examination, including staining with both trichrome and modified acid-fast stains. Differentiation between E. histolytica and E. dispar was performed using TechLab. Microscopic examination revealed that 19% of the samples were positive for Giardia, 4% for Cryptosporidium, and 1% for E. histolytica/E. dispar, and other parasites were found in 5%. By Triage, 23% of the samples were infected with Giardia, 5% with Cryptosporidium, and 2% with E. histolytica/E. dispar. Triage showed a sensitivity of 100% and specificity of 91.5%. The TechLab assay was negative for both samples diagnosed as E. histolytica/E. dispar by Triage, which suggested that they were E. dispar. Both tests showed no cross-reactivity with other intestinal protozoa. These results indicate that antigen detection by EIA has the potential to become a valuable tool, capable of making stool diagnostics more effective. Copyright © 2011 International Society for Infectious Diseases. Published by Elsevier Ltd. All rights reserved.

  6. Evaluation of a recombinant rhoptry protein 2 enzyme-linked immunoassay for the diagnosis of toxoplasmosis acquired during pregnancy.

    PubMed

    Capobiango, Jaqueline Dario; Pagliari, Sthefany; Pasquali, Aline Kuhn Sbruzzi; Nino, Beatriz; Ferreira, Fernanda Pinto; Monica, Thaís Cabral; Tschurtschenthaler, Nely Norder; Navarro, Italmar Teodorico; Garcia, João Luis; Mitsuka-Breganó, Regina; Reiche, Edna Maria Vissoci

    2015-09-01

    The aim of this study was to evaluate an enzyme-linked immunoassay with recombinant rhoptry protein 2 (ELISA-rROP2) for its ability to detect Toxoplasma gondii ROP2-specific IgG in samples from pregnant women. The study included 236 samples that were divided into groups according to serological screening profiles for toxoplasmosis: unexposed (n = 65), probable acute infection (n = 48), possible acute infection (n = 58) and exposed to the parasite (n = 65). When an indirect immunofluorescence assay forT. gondii-specific IgG was considered as a reference test, the ELISA-rROP2 had a sensitivity of 61.8%, specificity of 62.8%, predictive positive value of 76.6% and predictive negative value of 45.4% (p = 0.0002). The ELISA-rROP2 reacted with 62.5% of the samples from pregnant women with probable acute infection and 40% of the samples from pregnant women with previous exposure (p = 0.0180). Seropositivity was observed in 50/57 (87.7%) pregnant women with possible infection. The results underscored that T. gondii rROP2 is recognised by specific IgG antibodies in both the acute and chronic phases of toxoplasmosis acquired during pregnancy. However, the sensitivity of the ELISA-rROP2 was higher in the pregnant women with probable and possible acute infections and IgM reactivity.

  7. Seroprevalence of cytomegalovirus infection in France in 2010.

    PubMed

    Antona, D; Lepoutre, A; Fonteneau, L; Baudon, C; Halftermeyer-Zhou, F; LE Strat, Y; Lévy-Bruhl, D

    2017-05-01

    Cytomegalovirus (CMV) infection remains the leading cause of congenital virus infection in developed countries. Measuring the national prevalence of this infection, especially among women of childbearing age, is of great value to estimate the risk of congenital CMV infection, as well as to identify risk groups that should be targeted for behavioural interventions and/or vaccination once a CMV vaccine finally becomes available. In order to fulfil these objectives, a seroprevalence survey was conducted in 2010, using a nationally representative, population-based sample of 2536 people aged between 15 and 49 years, living in metropolitan France and attending private microbiological laboratories for blood testing. All blood samples were analysed in the same laboratory and screened for CMV-specific IgG using an enzyme-linked immunoassay technique (Elisa PKS Medac Enzyme immunoassay). The overall point estimate of CMV infection seroprevalence for individuals aged 15-49 years was 41.9%. The estimates were higher in women than in men (respectively 45.6% and 39.3%), and people born in a non-Western country were more likely to be CMV seropositive than those born in France or in another Western country (93.7% vs. 37.7%). Our results showed that a substantial percentage of women of childbearing age in France are CMV seronegative and therefore at risk of primary CMV infection during pregnancy. Educational measures and future vaccine are key issues to prevent infection in pregnant women and congenital CMV disease.

  8. Competitive Protein-binding assay-based Enzyme-immunoassay Method, Compared to High-pressure Liquid Chromatography, Has a Very Lower Diagnostic Value to Detect Vitamin D Deficiency in 9–12 Years Children

    PubMed Central

    Zahedi Rad, Maliheh; Neyestani, Tirang Reza; Nikooyeh, Bahareh; Shariatzadeh, Nastaran; Kalayi, Ali; Khalaji, Niloufar; Gharavi, Azam

    2015-01-01

    Background: The most reliable indicator of Vitamin D status is circulating concentration of 25-hydroxycalciferol (25(OH) D) routinely determined by enzyme-immunoassays (EIA) methods. This study was performed to compare commonly used competitive protein-binding assays (CPBA)-based EIA with the gold standard, high-pressure liquid chromatography (HPLC). Methods: Concentrations of 25(OH) D in sera from 257 randomly selected school children aged 9–11 years were determined by two methods of CPBA and HPLC. Results: Mean 25(OH) D concentration was 22 ± 18.8 and 21.9 ± 15.6 nmol/L by CPBA and HPLC, respectively. However, mean 25(OH) D concentrations of the two methods became different after excluding undetectable samples (25.1 ± 18.9 vs. 29 ± 14.5 nmol/L, respectively; P = 0.04). Based on predefined Vitamin D deficiency as 25(OH) D < 12.5 nmol/L, CPBA sensitivity and specificity were 44.2% and 60.6%, respectively, compared to HPLC. In receiver operating characteristic curve analysis, the best cut-offs for CPBA was 5.8 nmol/L, which gave 82% sensitivity, but specificity was 17%. Conclusions: Though CPBA may be used as a screening tool, more reliable methods are needed for diagnostic purposes. PMID:26330983

  9. Clostridium difficile infection diagnostics - evaluation of the C. DIFF Quik Chek Complete assay, a rapid enzyme immunoassay for detection of toxigenic C. difficile in clinical stool samples.

    PubMed

    Johansson, Karin; Karlsson, Hanna; Norén, Torbjörn

    2016-11-01

    Diagnostic testing for Clostridium difficile infection (CDI) has, in recent years, seen the introduction of rapid dual-EIA (enzyme immunoassay) tests combining species-specific glutamate dehydrogenase (GDH) with toxin A/B. In a prospective study, we compared the C. DIFF Quik Chek Complete test to a combination of selective culture (SC) and loop-mediated isothermal amplification (LAMP) of the toxin A gene. Of 419 specimens, 68 were positive in SC including 62 positive in LAMP (14.7%). The combined EIA yielded 82 GDH positives of which 47 were confirmed toxin A/B positive (11%) corresponding to a sensitivity and specificity of 94% for GDH EIA compared to SC and for toxin A/B EIA a sensitivity of 71% and a specificity of 99% compared to LAMP. Twenty different PCR ribotypes were evenly distributed except for UK 081 where only 25% were toxin A/B positive compared to LAMP. We propose a primary use of a combined GDH toxin A/B EIA permitting a sensitive 1-h result of 379 of 419 (90%, all negatives plus GDH and toxin EIA positives) referred specimens. The remaining 10% being GDH positive should be tested for toxin A/B gene on the same day and positive results left to a final decision by the physician. © 2016 APMIS. Published by John Wiley & Sons Ltd.

  10. [A system review on the application of BED-capture enzyme immunoassay in detecting new HIV-1 infection].

    PubMed

    Tao, Jun; Zhao, Jing; Liu, Yong; Meng, Ling-zhang; Yu, Shi-cheng; Jiang, Yan; Xiao, Yao

    2011-02-01

    To study whether BED-capture enzyme immunoassay (CEIA) is feasible to be used in wide-ranging population, we collect papers and conference abstracts related to BED-CEIA and HIV-1 incidence. 10 papers are included for the discussion, regarding the concordance between the estimated HIV-1 incidence from BED-CEIA and the results from a cohort studies; and 11 papers are selected to discuss the related misclassification on the estimation of HIV-1 incidence. Concordance between the two sets is related to the districts and design of research. Results from Africa are not so satisfactory, but researches, those BED-CEIA samples are collected during the follow-up of the cohort study, have shown better outcomes than other ones. There are totally 7303 samples of LTI (long-term infections) collected for analyzing the misclassification of BED-CEIA. 432 LTI are misclassified as new infections, making the raw rate of misclassification as 5.9% with 95% confidential interval between 5.36 and 6.44. Data from systematic review shows that the BED-CEIA's misclassification rate relates to the count of CD4(+)T lymphocytes and time after the infection but has no relation to the classification of sub-populations (female sexual workers and intravenous drug users in China) and districts (China and Africa). Our results reveal that the misclassification is relevant to the immune-status of the infected persons.

  11. A non-toxic enzyme-linked immunosorbent assay for aflatoxin B1 using anti-idiotypic antibodies as substitutes.

    PubMed

    Hu, Li; Liu, Aiping; Chen, Weifeng; Yang, Hongxiu; Wang, Xiaohong; Chen, Fusheng

    2017-03-01

    Immunoassays are widely employed techniques to detect aflatoxins since they are rapid, selective and sensitive. One common disadvantage of them is using aflatoxins as standard substances, which may trigger exposure risks to operators and environmental contamination without proper handling. Anti-idiotypic antibodies (anti-Ids or Ab2s), also named as internal-image anti-Ids, are able to mimic and function as antigens, so a non-toxic enzyme-linked immunosorbent assay (ELISA) for aflatoxin B 1 (AFB 1 ) is developed and validated using anti-Ids as substitutes. Mouse monoclonal anti-idiotypic antibody (McAb2) to AFB 1 was generated by the hybridoma technique using Fab fragments of rabbit anti-AFB 1 idiotype antibody (Ab1) as immunogen. As indicated by indirect competitive ELISA, McAb2, represented an internal-image of antigen AFB 1 , was able to bind Fab with competition to AFB 1 . Then, analysis of AFB 1 in spiked samples by non-toxic ELISA using anti-Ids as substitutes was developed, and it showed no significant differences with comparison to AFB 1 as competitive antigens. Our work demonstrated that anti-Ids could be used as internal-image mimicry of AFB 1 , and it had potential applications in immunoassays for antigen substitution to reduce operational risk for operators and environmental contamination. © 2016 Society of Chemical Industry. © 2016 Society of Chemical Industry.

  12. A toxin-free enzyme-linked immunosorbent assay for the analysis of aflatoxins based on a VHH surrogate standard.

    PubMed

    Wang, Yanru; Li, Peiwu; Zhang, Qi; Hu, Xiaofeng; Zhang, Wen

    2016-09-01

    A toxin-free enzyme-linked immunosorbent assay (ELISA) for aflatoxins was developed using an anti-idiotype nanobody VHH 2-5 as surrogate standard. Anti-idiotype nanobody VHH 2-5 was generated by immunizing an alpaca with anti-aflatoxin monoclonal antibody 1C11. This assay was used to detect aflatoxins in agro-products after a simple extraction with 75 % methanol/H2O. Aflatoxin concentration was calculated by a two-step approach: the concentration of VHH 2-5 was first obtained by a four-parameter logistic regression from the detected absorbance value at 450 nm, and then converted to aflatoxin concentration by a linear equation. The assay exhibits a limit of detection (LOD) of 0.015 ng mL(-1), which is better than or comparable with conventional immunoassays. The performance of our VHH surrogate-based ELISA was further validated with a high-performance liquid chromatography (HPLC) method for total aflatoxins determination in 20 naturally contaminated peanut samples, displaying a good correlation (R (2) = 0.988). In conclusion, the proposed assay represents a first example applying an anti-idiotype VHH antibody as a standard surrogate in ELISA. With the advantages of high stability and ease of production, the VHH antibody-based standard surrogate can be extended in the future to immunoassays for other highly toxic compounds. Graphical Abstract ᅟ.

  13. Antenatal screening for Toxoplasma gondii, Cytomegalovirus, rubella and Treponema pallidum infections in northern Benin.

    PubMed

    De Paschale, Massimo; Ceriani, Cristina; Cerulli, Teresa; Cagnin, Debora; Cavallari, Serena; Cianflone, Annalisa; Diombo, Kouma; Ndayaké, Joseph; Aouanou, Guy; Zaongo, Dieudonné; Priuli, Gianbattista; Viganò, Paolo; Clerici, Pierangelo

    2014-06-01

    Toxoplasma gondii, cytomegalovirus (HCMV) and rubella virus infections are among the most serious of those contracted during pregnancy in terms of foetal consequences. Toxoplasma, HCMV and rubella antibody screening is unusual in Africa, and there are few published data. The aim of this study was to evaluate the prevalence of these markers among pregnant women in northern Benin on the occasion of routine syphilis screening. Toxoplasma, HCMV and rubella IgG and IgM antibodies were determined in the serum of 283 women attending Saint Jean de Dieu de Tanguiéta hospital, using an enzyme immunoassay, and IgM were confirmed using an enzyme-linked fluorescent assay (ELFA). In the case of IgM positivity, the avidity of anti-HCMV and anti-Toxoplasma IgG was measured. Total anti-Treponema pallidum antibodies were determined using an enzyme immunoassay and confirmed by immunoblotting. In the case of positivity, the Venereal Disease Research Laboratory (VDRL) test was used. The prevalence of anti-Toxoplasma, anti-HCMV, anti-rubella IgG and total anti-Treponema antibodies was, respectively, 30.0%, 100%, 94% and 2.5%. The VDRL test was positive in 62.5% of the anti-Treponema-positive samples. The prevalence of anti-Toxoplasma, anti-HCMV and anti-rubella IgM was, respectively, 0.4%, 1.4% and 0%. There were no statistically significant differences in terms of age class or trimester of pregnancy. Anti-Toxoplasma and anti-HCMV IgG avidity was always high. The prevalence of HCMV and rubella antibodies is high in northern Benin, whereas that of Toxoplasma antibodies is lower. As nearly two-thirds of the pregnant women were anti-Toxoplasma seronegative, antibody screening should be introduced. © 2014 John Wiley & Sons Ltd.

  14. Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer.

    PubMed

    Chang, Yanli; Xu, Jianjun; Zhang, Qingyun

    2017-10-01

    Survivin is a tumor marker for bladder cancer; however the role of urinary survivin levels has not been fully elucidated due to the limitations of current detection methods. Based on two survivin-specific monoclonal antibodies (McAbs) already confirmed through enzyme linked immunosorbent assays, the present study aimed to establish a microplate magnetic chemiluminescence immunoassay (CLIA) for the detection of urinary survivin levels and evaluate its application for the diagnosis of patients with bladder cancer. Horseradish peroxidase and biotin conjugates were used to label two different anti-survivin McAbs, respectively. The labeled antibodies combined with survivin to form a sandwiched immune complex. The streptavidin magnetic particles (MPs) served as the solid phase and the separator. The relevant parameters involved in the immunoassay, including the immunoassay reagents used and the physicochemical parameters were optimized. Then, urine samples from 130 patients with bladder cancer and 113 healthy controls were detected, and analyzed using the established method. The method was linear to 1,000 ng/ml survivin with a detection limit of 0.83 ng/ml. The intra- and inter-assay coefficients of variation were <8, and <11%, respectively. The concentration of diluted survivin and the dilution ratios gave a linear correlation of 0.9989. The results demonstrated that the urinary survivin levels in patients with bladder cancer were significantly higher (P<0.001) compared with that in healthy controls. At a survivin concentration of 2.0884 ng/ml, the sensitivity and specificity were 86.9 and 61.9%, respectively. Furthermore, the urinary survivin levels were positively correlated with metastatic stage, histological stage and recurrence (P<0.01). In conclusion, the present study preliminarily proposed a microplate magnetic CLIA for survivin detection and further evaluated the value of urinary survivin as a diagnostic marker for bladder cancer.

  15. Microplate magnetic chemiluminescence immunoassay for detecting urinary survivin in bladder cancer

    PubMed Central

    Chang, Yanli; Xu, Jianjun; Zhang, Qingyun

    2017-01-01

    Survivin is a tumor marker for bladder cancer; however the role of urinary survivin levels has not been fully elucidated due to the limitations of current detection methods. Based on two survivin-specific monoclonal antibodies (McAbs) already confirmed through enzyme linked immunosorbent assays, the present study aimed to establish a microplate magnetic chemiluminescence immunoassay (CLIA) for the detection of urinary survivin levels and evaluate its application for the diagnosis of patients with bladder cancer. Horseradish peroxidase and biotin conjugates were used to label two different anti-survivin McAbs, respectively. The labeled antibodies combined with survivin to form a sandwiched immune complex. The streptavidin magnetic particles (MPs) served as the solid phase and the separator. The relevant parameters involved in the immunoassay, including the immunoassay reagents used and the physicochemical parameters were optimized. Then, urine samples from 130 patients with bladder cancer and 113 healthy controls were detected, and analyzed using the established method. The method was linear to 1,000 ng/ml survivin with a detection limit of 0.83 ng/ml. The intra- and inter-assay coefficients of variation were <8, and <11%, respectively. The concentration of diluted survivin and the dilution ratios gave a linear correlation of 0.9989. The results demonstrated that the urinary survivin levels in patients with bladder cancer were significantly higher (P<0.001) compared with that in healthy controls. At a survivin concentration of 2.0884 ng/ml, the sensitivity and specificity were 86.9 and 61.9%, respectively. Furthermore, the urinary survivin levels were positively correlated with metastatic stage, histological stage and recurrence (P<0.01). In conclusion, the present study preliminarily proposed a microplate magnetic CLIA for survivin detection and further evaluated the value of urinary survivin as a diagnostic marker for bladder cancer. PMID:28943911

  16. Implementation of a rapid HIT immunoassay at a university hospital - Retrospective analysis of HIT laboratory orders in patients with thrombocytopenia.

    PubMed

    Black, Anne; Heimerl, Susanne; Oertli, Linnéa; Wilczek, Wolf; Greinacher, Andreas; Spannagl, Michael; Herr, Wolfgang; Hart, Christina

    2017-10-01

    Heparin-induced thrombocytopenia (HIT) is a rare cause of thrombocytopenia and a potentially life-threatening adverse drug reaction. Clinical overdiagnosis of HIT results in costly laboratory tests and anticoagulation. Criteria and algorithms for diagnosis are established, but their translation into clinical practice is still challenging. In a retrospective approach we studied all HIT related laboratory test requests within four years and evaluated data before (1st period, 24month) and after (2nd period, 24month) replacing particle gel immunoassay (PaGIA) and enzyme-linked immunosorbent assay (ELISA) by a chemiluminescent immunoassay (CLIA). HIT was confirmed by heparin-induced platelet activation (HIPA) test. Clinical pretest probability for HIT using an implemented simplified 4Ts score and platelet count were evaluated. Costs for laboratory tests and alternative anticoagulation were calculated. In 1850 patients with suspected HIT, 2327 laboratory orders were performed. In 87.2% of these orders an intermediate/high simplified 4Ts score was found. Thrombocytopenia was present in 87.1%. After replacing PaGIA and ELISA by CLIA the number of immunological and functional laboratory tests was reduced by 38.2%. The number of positive HIT immunoassays declined from 22.6% to 6.0%, while the number of positive HIPA tests among positive immunological tests increased by 19%. Altogether, acute HIT was confirmed in 59 patients. A decline in the use of alternative anticoagulants was observed in the 2nd period. Our study shows that in a university hospital setting HIT is well-known, but diagnosis requires a precise laboratory confirmation. Replacing PaGIA and ELISA by CLIA did not influence laboratory order behavior but results in reduced overall costs for laboratory diagnostics and alternative anticoagulation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  17. Triclosan and methyl-triclosan monitoring study in the northeast of Spain using a magnetic particle enzyme immunoassay and confirmatory analysis by gas chromatography mass spectrometry

    NASA Astrophysics Data System (ADS)

    Kantiani, Lina; Farré, Marinella; Asperger, Danijela; Rubio, Fernando; González, Susana; López de Alda, Maria J.; Petrović, Mira; Shelver, Weilin L.; Barceló, Damià

    2008-10-01

    SummaryFor the first time, the occurrence of triclosan and its metabolite methyl-triclosan was investigated in a typical Mediterranean area using a two-step methodology based on screening using a magnetic particle immunoassay (IA) and confirmatory analysis by solid phase extraction (SPE) followed by gas chromatography-mass spectrometry (GC-MS). In this study, 95 environmental samples were analyzed. A commercial immunoassay was assessed for use in the different types of water selected for this study. A large monitoring study was performed on the influent and the effluent of eight wastewater treatment plants (WWTPs), water samples from Ebro and Llobregat rivers, and drinking water. All wastewater samples tested in this study (influents and effluents) showed the presence of triclosan, with concentrations for raw influents being high (10 μg/L as average value). The percentages of triclosan removal for the WWTPs were evaluated (30-70%) along the different treatment processes showing that the best removal rates were obtained by the processes equipped with membrane bioreactors (MBRs). However, important concentrations of triclosan were detected even after treatment by MBRs. The presence of this biocide was confirmed in 50% of the river samples analyzed. Twenty two drinking water samples from the Barcelona city area were investigated, and in this case no triclosan was detected. Due to its properties and the widespread usage of triclosan, there is a need for monitoring and controlling the amounts present in wastewater effluents, river water, drinking water catchments areas, and drinking water. To this end, we present a feasible methodology using a magnetic particle-based immunoassay as a screening, followed by confirmatory analysis using solid phase extraction-gas chromatography-mass spectrometry (SPE-GC-MS).

  18. Electrochemical immunoassay for vitellogenin based on sequential injection using antigen-immobilized magnetic microbeads.

    PubMed

    Hirakawa, Koji; Katayama, Masaaki; Soh, Nobuaki; Nakano, Koji; Imato, Toshihiko

    2006-01-01

    A rapid and sensitive immunoassay for the determination of vitellogenin (Vg) is described. The method involves a sequential injection analysis (SIA) system equipped with an amperometric detector and a neodymium magnet. Magnetic beads, onto which an antigen (Vg) was immobilized, were used as a solid support in an immunoassay. The introduction, trapping and release of magnetic beads in an immunoreaction cell were controlled by means of the neodymium magnet and by adjusting the flow of the carrier solution. The immunoassay was based on an indirect competitive immunoreaction of an alkaline phosphatase (ALP) labeled anti-Vg monoclonal antibody between the fraction of Vg immobilized on the magnetic beads and Vg in the sample solution. The immobilization of Vg on the beads involved coupling an amino group moiety of Vg with the magnetic beads after activation of a carboxylate moiety on the surface of magnetic beads that had been coated with a polylactate film. The Vg-immobilized magnetic beads were introduced and trapped in the immunoreaction cell equipped with the neodymium magnet; a Vg sample solution containing an ALP labeled anti-Vg antibody at a constant concentration and a p-aminophenyl phosphate (PAPP) solution were sequentially introduced into the immunoreaction cell. The product of the enzyme reaction of PAPP with ALP on the antibody, paminophenol, was transported to an amperometric detector, the applied voltage of which was set at +0.2 V vs. an Ag/AgCl reference electrode. A sigmoid calibration curve was obtained when the logarithm of the concentration of Vg was plotted against the peak current of the amperometric detector using various concentrations of standard Vg sample solutions (0-500 ppb). The time required for the analysis is less than 15 min.

  19. Methodological issues in assessing plasma 25-hydroxyvitamin D concentration in newborn infants.

    PubMed

    Gallo, Sina; Comeau, Kathryn; Agellon, Sherry; Vanstone, Catherine; Sharma, Atul; Jones, Glenville; L'abbé, Mary; Khamessan, Ali; Weiler, Hope; Rodd, Celia

    2014-04-01

    Although no gold standard exists, liquid chromatography tandem mass spectrometry (LC-MS/MS) is a precise and accurate method for the analysis of plasma 25-hydroxyvitamin D (25(OH)D). Immunoassays are more readily available and require small volume sampling, ideal for infant testing. The objective was to compare two commercially available immunoassays for measuring circulating 25(OH)D concentration in infant plasma against LC-MS/MS. Capillary blood samples from 103 infants were analyzed for plasma 25(OH)D using an enzyme immunoassay (EIA, Octeia, IDS Ltd.) and radioimmunoassay (RIA, DiaSorin). Plasma 25(OH)D(3), C-3 epimer of 25(OH)D(3) (3-epi-25(OH)D(3)) and 24,25-dihydroxyvitamin D (24,25(OH)(2)D(3)) were measured on the same samples using LC-MS/MS. To establish whether plasma 24,25(OH)(2)D(3) or 3-epi-25(OH)D(3) interferes with these immunoassay results, the zero 25(OH)D calibrator from each assay kit was spiked with increasing amounts of 24,25(OH)(2)D(3) or 3-epi-25(OH)D(3). Classifying infants below the common vitamin D status targets of 50 nmol/L and 75 nmol/L respectively, 58% and 99% fell below using the RIA, 19% and 56% with the EIA and 31% and 76% with LC-MS/MS. Compared to LC-MS/MS, both immunoassays showed poor Bland-Altman limits of agreement for 25(OH)D concentrations (RIA: limits of agreement -27 to +13%; EIA: -12 to +41%), and mountain plots (folded cumulative distribution) depicted significant skew and bias. Spiked 24,25(OH)2D3 concentrations, but not 3-epi-25(OH)D3, appeared as >100% of known values on the EIA but not on the RIA thus, suggesting that the EIA may cross-react with 24,25(OH)(2)D(3) to a greater extent than 3-epi-25(OH)D(3). Two common immunoassays resulted in very different classifications of vitamin D status possibly related to the interference of other vitamin D metabolites. Based on these data, LC-MS/MS assessment of vitamin D status is recommended in young infants (4-6 weeks of age). Copyright © 2014 Elsevier Inc. All rights reserved.

  20. Improving receiver performance of diffusive molecular communication with enzymes.

    PubMed

    Noel, Adam; Cheung, Karen C; Schober, Robert

    2014-03-01

    This paper studies the mitigation of intersymbol interference in a diffusive molecular communication system using enzymes that freely diffuse in the propagation environment. The enzymes form reaction intermediates with information molecules and then degrade them so that they cannot interfere with future transmissions. A lower bound expression on the expected number of molecules measured at the receiver is derived. A simple binary receiver detection scheme is proposed where the number of observed molecules is sampled at the time when the maximum number of molecules is expected. Insight is also provided into the selection of an appropriate bit interval. The expected bit error probability is derived as a function of the current and all previously transmitted bits. Simulation results show the accuracy of the bit error probability expression and the improvement in communication performance by having active enzymes present.

  1. The heat released during catalytic turnover enhances the diffusion of an enzyme

    PubMed Central

    Riedel, Clement; Gabizon, Ronen; Wilson, Christian A. M.; Hamadani, Kambiz; Tsekouras, Konstantinos; Marqusee, Susan; Pressé, Steve; Bustamante, Carlos

    2015-01-01

    Recent studies have shown that the diffusivity of enzymes increases in a substrate-dependent manner during catalysis1,2. Although this observation has been reported and characterized for several different systems3–10, the precise origin of this phenomenon is unknown. Calorimetric methods are often used to determine enthalpies from enzyme-catalysed reactions and can therefore provide important insight into their reaction mechanisms11,12. The ensemble averages involved in traditional bulk calorimetry cannot probe the transient effects that the energy exchanged in a reaction may have on the catalyst. Here we obtain single-molecule fluorescence correlation spectroscopy data and analyse them within the framework of a stochastic theory to demonstrate a mechanistic link between the enhanced diffusion of a single enzyme molecule and the heat released in the reaction. We propose that the heat released during catalysis generates an asymmetric pressure wave that results in a differential stress at the protein–solvent interface that transiently displaces the centre-of-mass of the enzyme (chemoacoustic effect). This novel perspective on how enzymes respond to the energy released during catalysis suggests a possible effect of the heat of reaction on the structural integrity and internal degrees of freedom of the enzyme. PMID:25487146

  2. The heat released during catalytic turnover enhances the diffusion of an enzyme

    DOE PAGES

    Riedel, Clement; Gabizon, Ronen; Wilson, Christian A. M.; ...

    2014-12-10

    Recent studies have shown that the diffusivity of enzymes increases in a substrate-dependent manner during catalysis. Although this observation has been reported and characterized for several different systems, the precise origin of this phenomenon is unknown. Calorimetric methods are often used to determine enthalpies from enzyme-catalysed reactions and can therefore provide important insight into their reaction mechanisms. The ensemble averages involved in traditional bulk calorimetry cannot probe the transient effects that the energy exchanged in a reaction may have on the catalyst. Here we obtain single-molecule fluorescence correlation spectroscopy data and analyse them within the framework of a stochastic theorymore » to demonstrate a mechanistic link between the enhanced diffusion of a single enzyme molecule and the heat released in the reaction. We propose that the heat released during catalysis generates an asymmetric pressure wave that results in a differential stress at the protein-solvent interface that transiently displaces the centre-of-mass of the enzyme (chemoacoustic effect). We find this novel perspective on how enzymes respond to the energy released during catalysis suggests a possible effect of the heat of reaction on the structural integrity and internal degrees of freedom of the enzyme.« less

  3. The toxicology and immunology of detergent enzymes.

    PubMed

    Basketter, David; Berg, Ninna; Kruszewski, Francis H; Sarlo, Katherine; Concoby, Beth

    2012-01-01

    Detergent enzymes have a very good safety profile, with almost no capacity to generate adverse acute or chronic responses in humans. The exceptions are the limited ability of some proteases to produce irritating effects at high concentrations, and the intrinsic potential of these bacterial and fungal proteins to act as respiratory sensitizers, demonstrated in humans during the early phase of the industrial use of enzymes during the 1960s and 1970s. How enzymes generate these responses are beginning to become a little clearer, with a developing appreciation of the cell surface mechanism(s) by which the enzymatic activity promotes the T-helper (T(H))-2 cell responses, leading to the generation of IgE. It is a reasonable assumption that the majority of enzyme proteins possess this intrinsic hazard. However, toxicological methods for characterizing further the respiratory sensitization hazard of individual enzymes remains a problematic area, with the consequence that the information feeding into risk assessment/management, although sufficient, is limited. Most of this information was in the past generated in animal models and in vitro immunoassays that assess immunological cross-reactivity. Ultimately, by understanding more fully the mechanisms which drive the IgE response to enzymes, it will be possible to develop better methods for hazard characterization and consequently for risk assessment and management.

  4. Molecular Diagnosis in Autoimmune Skin Blistering Conditions

    PubMed Central

    Otten, J.V.; Hashimoto, T.; Hertl, M.; Payne, A.S.; Sitaru, C.

    2014-01-01

    Blister formation in skin and mucous membranes results from a loss of cell-cell or cell-matrix adhesion and is a common outcome of pathological events in a variety of conditions, including autoimmune and genetic diseases, viral and bacterial infections, or injury by physical and chemical factors. Autoantibodies against structural components maintaining cell-cell and cell-matrix adhesion induce tissue damage in autoimmune blistering diseases. Detection of these autoantibodies either tissue-bound or circulating in serum is essential to diagnose the autoimmune nature of disease. Various immunofluorescence methods as well as molecular immunoassays, including enzyme-linked immunosorbent assay and immunoblotting, belong to the modern diagnostic algorithms for these disorders. There is still a considerable need to increase awareness of the rare autoimmune blistering diseases, which often show a severe, chronic-relapsing course, among physicians and the public. This review article describes the immunopathological features of autoimmune bullous diseases and the molecular immunoassays currently available for their diagnosis and monitoring. PMID:24160488

  5. A new paper-based platform technology for point-of-care diagnostics.

    PubMed

    Gerbers, Roman; Foellscher, Wilke; Chen, Hong; Anagnostopoulos, Constantine; Faghri, Mohammad

    2014-10-21

    Currently, the Lateral flow Immunoassays (LFIAs) are not able to perform complex multi-step immunodetection tests because of their inability to introduce multiple reagents in a controlled manner to the detection area autonomously. In this research, a point-of-care (POC) paper-based lateral flow immunosensor was developed incorporating a novel microfluidic valve technology. Layers of paper and tape were used to create a three-dimensional structure to form the fluidic network. Unlike the existing LFIAs, multiple directional valves are embedded in the test strip layers to control the order and the timing of mixing for the sample and multiple reagents. In this paper, we report a four-valve device which autonomously directs three different fluids to flow sequentially over the detection area. As proof of concept, a three-step alkaline phosphatase based Enzyme-Linked ImmunoSorbent Assay (ELISA) protocol with Rabbit IgG as the model analyte was conducted to prove the suitability of the device for immunoassays. The detection limit of about 4.8 fm was obtained.

  6. A retrospective analysis of sera collected by the Hemorrhagic Fever Commission during the Korean Conflict.

    PubMed

    LeDuc, J W; Ksiazek, T G; Rossi, C A; Dalrymple, J M

    1990-11-01

    More than 600 sera from 245 patients with a clinical diagnosis of hemorrhagic fever were preserved by the Hemorrhagic Fever Commission during the Korean Conflict, 1951-1954. These sera were tested for IgM- and IgG-specific antibodies to Hantaan virus by enzyme immunoassay and for hantaviral antigen by immunoassay; one serum from each patient was tested by plaque reduction neutralization using both Hantaan and Seoul viruses. Only 15 patients failed to develop antihantaviral antibodies; most sera contained high titered IgM antibody on admission, and all were IgM-seropositive by day 7 after onset. Attempts to detect hantaviral antigen were unsuccessful. All seropositive patients had highest plaque reduction neutralization titers to Hantaan virus, suggesting that this virus was responsible for the disease seen. These results confirm that hemorrhagic fever of the Korean Conflict was due to Hantaan virus and demonstrate that measurement of specific IgM antibody is the method of choice for diagnosis of acute disease.

  7. Detection of Serum microRNAs From Department of Defense Serum Repository

    PubMed Central

    Woeller, Collynn F.; Thatcher, Thomas H.; Van Twisk, Daniel; Pollock, Stephen J.; Croasdell, Amanda; Kim, Nina; Hopke, Philip K.; Xia, Xiaoyan; Thakar, Juilee; Mallon, COL Timothy M.; Utell, Mark J.; Phipps, Richard P.

    2017-01-01

    Objective The aim of this study was to investigate whether serum samples from the Department of Defense Serum Repository (DoDSR) are of sufficient quality to detect microRNAs (miRNAs), cytokines, immunoglobulin E (IgE), and polycyclic aromatic hydrocarbons (PAHs). Methods MiRNAs were isolated and quantified by polymerase chain reaction (PCR) array. Cytokines and chemokines related to inflammation were measured using multiplex immunoassays. Cotinine and IgE were detected by enzyme-linked immunoassay (ELISA) and PAHs were detected by Liquid Chromatography/Mass Spectroscopy. Results We detected miRNAs, cytokines, IgE, and PAHs with high sensitivity. Eleven of 30 samples tested positive for cotinine suggesting tobacco exposure. Significant associations between serum cotinine, cytokine, IgE, PAHs, and miRNA were discovered. Conclusion We successfully quantified over 200 potential biomarkers of occupational exposure from DoDSR samples. The stored serum samples were not affected by hemolysis and represent a powerful tool for biomarker discovery and analysis in retrospective studies. PMID:27501106

  8. Protein detection using biobarcodes.

    PubMed

    Müller, Uwe R

    2006-10-01

    Over the past 50 years the development of assays for the detection of protein analytes has been driven by continuing demands for higher levels of sensitivity and multiplexing. The result has been a progression of sandwich-type immunoassays, starting with simple radioisotopic, colorimetric, or fluorescent labeling systems to include various enzymatic or nanostructure-based signal amplification schemes, with a concomitant sensitivity increase of over 1 million fold. Multiplexing of samples and tests has been enabled by microplate and microarray platforms, respectively, or lately by various molecular barcoding systems. Two different platforms have emerged as the current front-runners by combining a nucleic acid amplification step with the standard two-sided immunoassay. In both, the captured protein analyte is replaced by a multiplicity of oligonucleotides that serve as surrogate targets. One of these platforms employs DNA or RNA polymerases for the amplification step, while detection is by fluorescence. The other is based on gold nanoparticles for both amplification as well as detection. The latter technology, now termed Biobarcode, is completely enzyme-free and offers potentially much higher multiplexing power.

  9. Sensitive, Fast, and Specific Immunoassays for Methyltestosterone Detection

    PubMed Central

    Kong, Na; Song, Shanshan; Peng, Juan; Liu, Liqiang; Kuang, Hua; Xu, Chuanlai

    2015-01-01

    An indirect competitive enzyme-linked immunosorbent assay (icELISA) and an immunochromatographic strip assay using a highly specific monoclonal antibody, were developed to detect methyltestosterone (MT) residues in animal feed. The optimized icELISA had a half-inhibition concentration value of 0.26 ng/mL and a limit of detection value of 0.045 ng/mL. There was no cross-reactivity with eight analogues, revealing high specificity for MT. Based on icELISA results, the recovery rate of MT in animal feed was 82.4%–100.6%. The results were in accordance with those obtained by gas chromatography-mass spectrometry. The developed immunochromatographic strip assay, as the first report for MT detection, had a visual cut-off value of 1 ng/mL in PBS, 2.5 ng/g in fish feed, and 2.5 ng/g in pig feed. Therefore, these immunoassays are useful and fast tools for MT residue detection in animal feed. PMID:25938198

  10. A direct immunoassay for detecting diatoms in groundwater as an indicator of the direct influence of surface water

    USGS Publications Warehouse

    Walker, C.E.; Schrock, R.M.; Reilly, T.J.; Baehr, A.L.

    2005-01-01

    Groundwater under the direct influence of surface water (GWUDISW) is of concern in communities where growing public demand on groundwater resources has resulted in increased withdrawals and hydraulic stress near surface water bodies. Under these conditions, contaminants such as methyl-tert butyl ether (MTBE) and biological materials have been detected in domestic wells. Other contaminants and pathogens associated with surface water are not routinely tested for in groundwater-supplied systems. To address the need for methods to easily identify potentially vulnerable supplies, a direct immunoassay for the quantitative detection of diatoms in raw water samples was developed as a measure of surface water influence on groundwater. Cell wall preparations from Nitzschia palea Ku??tzing, a freshwater diatom found throughout North America, were used to produce a polyclonal antibody that was applied in a direct enzyme-linked immunosorbent assay (ELISA) developed to detect the presence of N. palea cell wall components. The direct immunoassay allows detection at 500 cells L-1, a level similar to diatom concentrations observed in samples of groundwater collected near the test site. This investigation was the first attempt to utilize an ELISA as an indicator of surface water influence on groundwater. Further research is needed to develop more specific diatom-based monoclonal antibodies, determine cross-reactivity, and optimize sample processing and ELISA procedures for development of a standardized method. ?? Springer 2005.

  11. A direct immunoassay for detecting diatoms in groundwater as an indicator of the direct influence of surface water

    USGS Publications Warehouse

    Walker, C.E.; Schrock, R.M.; Reilly, T.J.; Baehr, A.L.

    2005-01-01

    Groundwater under the direct influence of surface water (GWUDISW) is of concern in communities where growing public demand on groundwater resources has resulted in increased withdrawals and hydraulic stress near surface water bodies. Under these conditions, contaminants such as methyl-tert butyl ether (MTBE) and biological materials have been detected in domestic wells. Other contaminants and pathogens associated with surface water are not routinely tested for in groundwater-supplied systems. To address the need for methods to easily identify potentially vulnerable supplies, a direct immunoassay for the quantitative detection of diatoms in raw water samples was developed as a measure of surface water influence on groundwater. Cell wall preparations from Nitzschia palea Kützing, a freshwater diatom found throughout North America, were used to produce a polyclonal antibody that was applied in a direct enzyme-linked immunosorbent assay (ELISA) developed to detect the presence of N. palea cell wall components. The direct immunoassay allows detection at 500 cells L−1, a level similar to diatom concentrations observed in samples of groundwater collected near the test site. This investigation was the first attempt to utilize an ELISA as an indicator of surface water influence on groundwater. Further research is needed to develop more specific diatom-based monoclonal antibodies, determine cross-reactivity, and optimize sample processing and ELISA procedures for development of a standardized method.

  12. Preparation of peanut butter suspension for determination of peanuts using enzyme-linked immunoassay kits.

    PubMed

    Trucksess, Mary W; Brewer, Vickery A; Williams, Kristina M; Westphal, Carmen D; Heeres, James T

    2004-01-01

    Peanuts are one of the 8 most common allergenic foods and a large proportion of peanut-allergic individuals have severe reactions, some to minimal exposure. Specific protein constituents in the peanuts are the cause of the allergic reactions in sensitized individuals who ingest the peanuts. To avoid accidental ingestion of peanut-contaminated food, methods of analysis for the determination of the allergenic proteins in foods are important tools. Such methods could help identify foods inadvertently contaminated with peanuts, thereby reducing the incidence of allergic reactions to peanuts. Commercial immunoassay kits are available but need study for method performance, which requires reference materials for within- and between-laboratory validations. In this study, National Institute of Standards and Technology Standard Reference Material 2387 peanut butter was used. A polytron homogenizer was used to prepare a homogenous aqueous Peanut Butter suspension for the evaluation of method performance of some commercially available immunoassay kits such as Veratox for Peanut Allergen Test (Neogen Corp.), Ridascreen Peanut (R-Biopharm GmbH), and Bio-Kit Peanut Protein Assay Kit (Tepnel). Each gram of the aqueous peanut butter suspension contained 20 mg carboxymethylcellulose sodium salt, 643 microg peanut, 0.5 mg thimerosal, and 2.5 mg bovine serum albumin. The suspension was homogenous, stable, reproducible, and applicable for adding to ice cream, cookies, breakfast cereals, and chocolate for recovery studies at spike levels ranging from 12 to 90 microg/g.

  13. Evaluation of Non-Lethal Effects of N2 Bubbles on Marine Mammal Health and the Potential Role of Immune Activity in Facilitating the Development of Dive Related Injury

    DTIC Science & Technology

    2015-09-30

    control for confounding effects of changing physiological status. Cortisol will be measured using a commercial enzyme immunoassay ( EIA ) and plasma...complement activity in plasma and serum has been tested using zymosan (Sigma Aldrich) which is a known activator of complement. Validation of the EIA ...expected to be underway by November 2015. Data collection for objective 3 will occur during project year 2. RESULTS EIA kits for seal

  14. Immunoassays for Identification of Biological Agents in Sample Unknowns: NATO SlBCA Exercise VI

    DTIC Science & Technology

    2005-12-01

    Yersiniapestis 103 cfu/mL Enzyme-linked immunosorbent assays Antibodies Unlabelled antibodies Antibody stocks developed under DRES contract by SciLab Consulting...goat anti-rabbit IgG, (whole molecule, lot no. 90H8990). Antibody purification Antibodies produced by Scilab Consulting Inc. were purified on a Bio...No. W7702-4-R430, Final Report. Scilab Consulting Inc. DRDC Suffield TM 2005-223 17 14. Fulton, R.E. and Thompson, H.G. Evaluation of the Rapid

  15. Evaluation of Cytokine Synthesis in Human Whole Blood by Enzyme Linked Immunoassay (ELISA), Reverse Transcriptase Polymerase Chain Reaction (RT-PCR), and Flow Cytometry

    DTIC Science & Technology

    2007-05-08

    deoxynucleotide triphosphates, from Sigma. Sequences for glyceraldehyde-3-phosphate dehydrogenase ( G3PDH ), IL-8,and TNF-a were amplified with primer...This was accomplished by normalizing all samples to the mRNA for the moderately expressed housekeeping function glyceraldehyde-3 -phosphate...without and with isolation of cells before reverse transcription and PCR. G3PDH mRNA target amplifies at 983 base pairs. The 630 base pair band is the

  16. Acquisition of Heat Stable Enzymes from Thermophilic Microorganisms: Peroxidases, Ureases, and Glucose Oxidases.

    DTIC Science & Technology

    1992-04-01

    foetus antibody (approx. 43.8 mg/ mL) (Nakane). After conjugation, unconjugated antibody and urease were separated from the IgG-Urease conjugate by...using fixed T. foetus organisms were incubated in 10 mM citrate buffer, pH 7, as a control or IgG-Urease in the same citrate buffer for 15 min. Organisms...Table 15. T. foetus - Anti T. foetus Model Immunoassay Relative Urease Activity Reaction (Absofbances @590 nm) T. foetus + Buffer Control 0.501 IgG-Urease

  17. Introducing MINA--The Molecularly Imprinted Nanoparticle Assay.

    PubMed

    Shutov, Roman V; Guerreiro, Antonio; Moczko, Ewa; de Vargas-Sansalvador, Isabel Perez; Chianella, Iva; Whitcombe, Michael J; Piletsky, Sergey A

    2014-03-26

    A new ELISA- (enzyme-linked immunosorbent assay)-like assay is demonstrated in which no elements of biological origin are used for molecular recognition or signaling. Composite imprinted nanoparticles that contain a catalytic core and which are synthesized by using a solid-phase approach can simultaneously act as recognition/signaling elements, and be used with minimal modifications to standard assay protocols. This assay provides a new route towards replacement of unstable biomolecules in immunoassays. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  18. Risks Associated with Fresh Whole Blood and Red Blood Cell Transfusions in a Combat Support Hospital

    DTIC Science & Technology

    2007-01-01

    collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE 2007 2 . REPORT TYPE 3 . DATES COVERED 00-00-2007...coagulation function [13, 14] Increased RBC aggregation [28] Increased free hemoglobin [29] Decreased 2 , 3 DPG and tissue perfusion [30] Decreased oxygen...0.07%) were positive for human lymphotropic virus enzyme immunoassay, and none of 2,831 were positive for both human immunodeficiency virus 1/ 2 and

  19. Optical fiber-based biosensors.

    PubMed

    Monk, David J; Walt, David R

    2004-08-01

    This review outlines optical fiber-based biosensor research from January 2001 through September 2003 and was written to complement the previous review in this journal by Marazuela and Moreno-Bondi. Optical fiber-based biosensors combine the use of a biological recognition element with an optical fiber or optical fiber bundle. They are classified by the nature of the biological recognition element used for sensing: enzyme, antibody/antigen (immunoassay), nucleic acid, whole cell, and biomimetic, and may be used for a variety of analytes ranging from metals and chemicals to physiological materials.

  20. Ultrasensitive fluorescence immunoassay for detection of ochratoxin A using catalase-mediated fluorescence quenching of CdTe QDs

    NASA Astrophysics Data System (ADS)

    Huang, Xiaolin; Zhan, Shengnan; Xu, Hengyi; Meng, Xianwei; Xiong, Yonghua; Chen, Xiaoyuan

    2016-04-01

    Herein, for the first time we report an improved competitive fluorescent enzyme linked immunosorbent assay (ELISA) for the ultrasensitive detection of ochratoxin A (OTA) by using hydrogen peroxide (H2O2)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (QDs). In this immunoassay, catalase (CAT) was labeled with OTA as a competitive antigen to connect the fluorescence signals of the QDs with the concentration of the target. Through the combinatorial use of H2O2-induced fluorescence quenching of CdTe QDs as a fluorescence signal output and the ultrahigh catalytic activity of CAT to H2O2, our proposed method could be used to perform a dynamic linear detection of OTA ranging from 0.05 pg mL-1 to 10 pg mL-1. The half maximal inhibitory concentration was 0.53 pg mL-1 and the limit of detection was 0.05 pg mL-1. These values were approximately 283- and 300-folds lower than those of horseradish peroxidase (HRP)-based conventional ELISA, respectively. The reported method is accurate, highly reproducible, and specific against other mycotoxins in agricultural products as well. In summary, the developed fluorescence immunoassay based on H2O2-induced fluorescence quenching of CdTe QDs can be used for the rapid and highly sensitive detection of mycotoxins or haptens in food safety monitoring.Herein, for the first time we report an improved competitive fluorescent enzyme linked immunosorbent assay (ELISA) for the ultrasensitive detection of ochratoxin A (OTA) by using hydrogen peroxide (H2O2)-induced fluorescence quenching of mercaptopropionic acid-modified CdTe quantum dots (QDs). In this immunoassay, catalase (CAT) was labeled with OTA as a competitive antigen to connect the fluorescence signals of the QDs with the concentration of the target. Through the combinatorial use of H2O2-induced fluorescence quenching of CdTe QDs as a fluorescence signal output and the ultrahigh catalytic activity of CAT to H2O2, our proposed method could be used to perform a dynamic linear detection of OTA ranging from 0.05 pg mL-1 to 10 pg mL-1. The half maximal inhibitory concentration was 0.53 pg mL-1 and the limit of detection was 0.05 pg mL-1. These values were approximately 283- and 300-folds lower than those of horseradish peroxidase (HRP)-based conventional ELISA, respectively. The reported method is accurate, highly reproducible, and specific against other mycotoxins in agricultural products as well. In summary, the developed fluorescence immunoassay based on H2O2-induced fluorescence quenching of CdTe QDs can be used for the rapid and highly sensitive detection of mycotoxins or haptens in food safety monitoring. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr01136e

  1. Two-dimensional enzyme diffusion in laterally confined DNA monolayers.

    PubMed

    Castronovo, Matteo; Lucesoli, Agnese; Parisse, Pietro; Kurnikova, Anastasia; Malhotra, Aseem; Grassi, Mario; Grassi, Gabriele; Scaggiante, Bruna; Casalis, Loredana; Scoles, Giacinto

    2011-01-01

    Addressing the effects of confinement and crowding on biomolecular function may provide insight into molecular mechanisms within living organisms, and may promote the development of novel biotechnology tools. Here, using molecular manipulation methods, we investigate restriction enzyme reactions with double-stranded (ds)DNA oligomers confined in relatively large (and flat) brushy matrices of monolayer patches of controlled, variable density. We show that enzymes from the contacting solution cannot access the dsDNAs from the top-matrix interface, and instead enter at the matrix sides to diffuse two-dimensionally in the gap between top- and bottom-matrix interfaces. This is achieved by limiting lateral access with a barrier made of high-density molecules that arrest enzyme diffusion. We put forward, as a possible explanation, a simple and general model that relates these data to the steric hindrance in the matrix, and we briefly discuss the implications and applications of this strikingly new phenomenon.

  2. Nanoparticle bioconjugates as "bottom-up" assemblies of artifical multienzyme complexes

    NASA Astrophysics Data System (ADS)

    Keighron, Jacqueline D.

    2010-11-01

    The sequential enzymes of several metabolic pathways have been shown to exist in close proximity with each other in the living cell. Although not proven in all cases, colocalization may have several implications for the rate of metabolite formation. Proximity between the sequential enzymes of a metabolic pathway has been proposed to have several benefits for the overall rate of metabolite formation. These include reduced diffusion distance for intermediates, sequestering of intermediates from competing pathways and the cytoplasm. Restricted diffusion in the vicinity of an enzyme can also cause the pooling of metabolites, which can alter reaction equilibria to control the rate of reaction through inhibition. Associations of metabolic enzymes are difficult to isolate ex vivo due to the weak interactions believed to colocalize sequential enzymes within the cell. Therefore model systems in which the proximity and diffusion of intermediates within the experiment system are controlled are attractive alternatives to explore the effects of colocalization of sequential enzymes. To this end three model systems for multienzyme complexes have been constructed. Direct adsorption enzyme:gold nanoparticle bioconjugates functionalized with malate dehydrogenase (MDH) and citrate synthase (CS) allow for proximity between to the enzymes to be controlled from the nanometer to micron range. Results show that while the enzymes present in the colocalized and non-colocalized systems compared here behaved differently overall the sequential activity of the pathway was improved by (1) decreasing the diffusion distance between active sites, (2) decreasing the diffusion coefficient of the reaction intermediate to prevent escape into the bulk solution, and (3) decreasing the overall amount of bioconjugate in the solution to prevent the pathway from being inhibited by the buildup of metabolite over time. Layer-by-layer (LBL) assemblies of MDH and CS were used to examine the layering effect of sequential enzymes found in multienzyme complexes such as the pyruvate dehydrogenase complex (PDC). By controlling the orientation of enzymes in the complex (i.e. how deeply embedded each enzyme is) it was hypothesized that differences in sequential activity would determine an optimal orientation for a multienzyme complex. It was determined during the course of these experiments that the polyelectrolyte (PE) assembly itself served to slow diffusion of intermediates, leading to a buildup of oxaloacetate within the PE layers to form a pool of metabolite that equalized the rate of sequential reaction between the different orientations tested. Hexahistidine tag -- Ni(II) nitriliotriacetic acid (NTA) chemistry is an attractive method to control the proximity between sequential enzymes because each enzyme can be bound in a specific orientation, with minimal loss of activity, and the interaction is reversible. Modifying gold nanoparticles or large unilamellar vesicles with this functionality allows for another class of model to be constructed in which proximity between enzymes is dynamic. Some metabolic pathways (such as the de novo purine biosynthetic pathway), have demonstrated dynamic proximity of sequential enzymes in response to specific cellular stimuli. Results indicate that Ni(II)NTA scaffolds immobilize histidine-tagged enzymes non-destructively, with a near 100% reversibility. This model can be used to demonstrate the possible implications of dynamic proximity such as pathway regulation. Insight into the benefits and mechanisms of sequential enzyme colocalization can enhance the general understanding of cellular processes, as well as allow for the development of new and innovative ways to modulate pathway activity. This may provide new designs for treatments of metabolic diseases and cancer, where metabolic pathways are altered.

  3. Atypical profiles and modulations of heme-enzymes catalyzed outcomes by low amounts of diverse additives suggest diffusible radicals' obligatory involvement in such redox reactions.

    PubMed

    Manoj, Kelath Murali; Parashar, Abhinav; Venkatachalam, Avanthika; Goyal, Sahil; Satyalipsu; Singh, Preeti Gunjan; Gade, Sudeep K; Periyasami, Kalaiselvi; Jacob, Reeba Susan; Sardar, Debosmita; Singh, Shanikant; Kumar, Rajan; Gideon, Daniel A

    2016-06-01

    Peroxidations mediated by heme-enzymes have been traditionally studied under a single-site (heme distal pocket), non-sequential (ping-pong), two-substrates binding scheme of Michaelis-Menten paradigm. We had reported unusual modulations of peroxidase and P450 reaction outcomes and explained it invoking diffusible reactive species [Manoj, 2006; Manoj et al., 2010; Andrew et al., 2011, Parashar et al., 2014 & Venkatachalam et al., 2016]. A systematic investigation of specific product formation rates was undertaken to probe the hypothesis that involvement of diffusible reactive species could explain undefined substrate specificities and maverick modulations (sponsored by additives) of heme-enzymes. When the rate of specific product formation was studied as a function of reactants' concentration or environmental conditions, we noted marked deviations from normal profiles. We report that heme-enzyme mediated peroxidations of various substrates are inhibited (or activated) by sub-equivalent concentrations of diverse redox-active additives and this is owing to multiple redox equilibriums in the milieu. At low enzyme and peroxide concentrations, the enzyme is seen to recycle via a one-electron (oxidase) cycle, which does not require the substrate to access the heme centre. Schemes are provided that explain the complex mechanistic cycle, kinetics & stoichiometry. It is not obligatory for an inhibitor or substrate to interact with the heme centre for influencing overall catalysis. Roles of diffusible reactive species explain catalytic outcomes at low enzyme and reactant concentrations. The current work highlights the scope/importance of redox enzyme reactions that could occur "out of the active site" in biological or in situ systems. Copyright © 2016 Elsevier B.V. and Société française de biochimie et biologie Moléculaire (SFBBM). All rights reserved.

  4. Hepatitis C prevalence and the significance of liver enzyme elevations in the insurance population.

    PubMed

    Stout, R L

    1997-01-01

    Liver enzyme elevation(s) are a common finding in the insurance applicant population. Hepatitis C infection results in histological and functional changes in the liver with both short and long term changes in serum liver enzyme levels. The prevalence of antibodies to HCV in the general population is estimated to be 4%. This paper reports on the prevalence of antibodies to HCV in the insurance applicant population and their relationship to the liver enzyme(s). Antibodies to HCV are present in 1.8% of a random sampling of insurance applicants. Alanine aminotransferase (ALT) elevations occur in 95.4% of all samples positive for antibodies to HCV. More than half of positive samples (56.7%) have ALT elevations of less than two time the upper range of normal. Antibody prevalence is lowest in samples with single enzyme elevation, 4.2%. In comparison, the prevalence is 16.4% in samples with all three enzymes, ALT, AST, and GGT, elevated. For maximal specificity two immunoassays, configured with different HCV antigens, should be performed sequentially on all positive applicant samples. HCV is the most prevalent, chronic viral infection in the insurance population. HCV prevalence is 40 times HIV prevalence. In an evaluation of enzyme reflex markers ALT was positive for antibodies to HCV 8.6% of the time while identifying 95.4% of HCV antibody positive applicants.

  5. Rapid immunoassays for diagnosis of heparin-induced thrombocytopenia: Comparison of diagnostic accuracy, reproducibility, and costs in clinical practice

    PubMed Central

    Bankova, Andriyana; Andres, Yvonne; Horn, Michael P.; Alberio, Lorenzo

    2017-01-01

    Background Immunoassays are crucial in the work-up of patients with suspected heparin-induced thrombocytopenia (HIT) and rapid tests have been recently developed. However, comparative data on diagnostic accuracy, reproducibility, and analytical costs of different immunoassays in clinical practice are limited. Methods Samples of 179 consecutive patients evaluated for suspected HIT in clinical practice using a polyspecific enzyme-linked immunoabsorbent assay (GTI diagnostics; ELISA) and a rapid particle gel immunoassay (PaGIA), were additionally analysed with a IgG-specific chemiluminescent immunoassay (AcuStar HIT-IgG). Presence of HIT was defined as a positive functional heparin-induced platelet aggregation test. Diagnostic accuracy was determined for low, intermediate and high thresholds as previously established (ELISA: optical density 0.4, 1.3, and 2.0 respectively; PaGIA: positive/negative, titre of 4, titre of 32; AcuStar HIT-IgG: 1.0 U/ml, 2.8, 9.4) and reproducibility was assessed by repeated measurements. Costs of test determination were calculated taking reagents, controls, and working time of technicians according to Swiss health care system into account. Results Data on PaGIA results were available for 171 patients (95.5%), ELISA for 144 patients (80.4%), and AcuStar HIT-IgG for 179 patients (100%). Sensitivity was above 95% for all assays at low and intermediate thresholds. Specificity increased with higher thresholds and was above 90% for all assays with intermediate and high thresholds. Specificity of AcuStar HIT-IgG (92.8%; 95% CI 87.7, 96.2) was significantly higher than PaGIA (83.0%; 95% CI 76.3, 88.5) and higher than ELISA (81.8%, 95% CI 74.2, 88.0) at low threshold (p<0.05). Reproducibility was adequate for all assays. Total costs per test were CHF 51.02 for ELISA, 117.70 for AcuStar HIT-IgG, and 83.13 for PaGIA. Conclusions We observed favourable diagnostic accuracy measures and a high reproducibility for PaGIA and AcuStar HIT-IgG. Implementation into 24-hours-service might improve patient care but the results must be confirmed in other settings and larger populations as well. PMID:28594835

  6. Electrostatic steering and ionic tethering in enzyme-ligand binding: insights from simulations.

    PubMed

    Wade, R C; Gabdoulline, R R; Lüdemann, S K; Lounnas, V

    1998-05-26

    To bind at an enzyme's active site, a ligand must diffuse or be transported to the enzyme's surface, and, if the binding site is buried, the ligand must diffuse through the protein to reach it. Although the driving force for ligand binding is often ascribed to the hydrophobic effect, electrostatic interactions also influence the binding process of both charged and nonpolar ligands. First, electrostatic steering of charged substrates into enzyme active sites is discussed. This is of particular relevance for diffusion-influenced enzymes. By comparing the results of Brownian dynamics simulations and electrostatic potential similarity analysis for triose-phosphate isomerases, superoxide dismutases, and beta-lactamases from different species, we identify the conserved features responsible for the electrostatic substrate-steering fields. The conserved potentials are localized at the active sites and are the primary determinants of the bimolecular association rates. Then we focus on a more subtle effect, which we will refer to as "ionic tethering." We explore, by means of molecular and Brownian dynamics simulations and electrostatic continuum calculations, how salt links can act as tethers between structural elements of an enzyme that undergo conformational change upon substrate binding, and thereby regulate or modulate substrate binding. This is illustrated for the lipase and cytochrome P450 enzymes. Ionic tethering can provide a control mechanism for substrate binding that is sensitive to the electrostatic properties of the enzyme's surroundings even when the substrate is nonpolar.

  7. Selective biotinylation of Neisseria meningitidis group B capsular polysaccharide and application in an improved ELISA for the detection of specific antibodies.

    PubMed

    Diaz Romero, J; Outschoorn, I

    1993-03-15

    A method is described for the selective biotinylation of meningococcal capsular polysaccharide from Neisseria meningitidis group B and its application to an enzyme-linked immunoabsorbent assay (ELISA) to detect specific antibodies by immobilization on streptavidin-coated microtiter wells. Capsular polysaccharide from Neisseria meningitidis B has been biotinylated by specific periodate oxidation of terminal residues and condensation of the resulting aldehydes with biotin hydrazide, using a spin-column technique in the intermediate purification steps. The ELISA was optimized employing an extended reaction time between the label alkaline phosphatase and its most common substrate, p-nitrophenyl phosphate, together with evaluation of blocking agents to minimize non-specific binding. Specificity was demonstrated by a direct competitive enzyme immunoassay (EIA).

  8. Basic analytical methods for identification of erythropoiesis-stimulating agents in doping control

    NASA Astrophysics Data System (ADS)

    Postnikov, P. V.; Krotov, G. I.; Efimova, Yu A.; Rodchenkov, G. M.

    2016-02-01

    The design of new erythropoiesis-stimulating agents for clinical use necessitates constant development of methods for detecting the abuse of these substances, which are prohibited under the World Anti-Doping Code and are included in the World Anti-Doping Agency (WADA) prohibited list. This review integrates and describes systematically the published data on the key methods currently used by WADA-accredited anti-doping laboratories around the world to detect the abuse of erythropoiesis-stimulating agents, including direct methods (various polyacrylamide gel electrophoresis techniques, enzyme-linked immunosorbent assay, membrane enzyme immunoassay and mass spectrometry) and indirect methods (athlete biological passport). Particular attention is given to promising approaches and investigations that can be used to control prohibited erythropoietins in the near future. The bibliography includes 122 references.

  9. Enzyme immunoassay for the detection of porcine gelatine in edible bird's nests.

    PubMed

    Tukiran, Nur Azira; Ismail, Amin; Mustafa, Shuhaimi; Hamid, Muhajir

    2015-01-01

    Porcine gelatine is a common adulterant found in edible bird's nests (EBNs) used to increase the net weight prior to sale. This study aimed to develop indirect enzyme-linked immunosorbent assays (ELISAs) for porcine gelatine adulteration using anti-peptide polyclonal antibodies. Three indirect ELISAs were developed (PAB1, 2 and 3), which had limits of detection (LODs) of 0.12, 0.10 and 0.11 µg g(-1), respectively. When applied to standard solutions of porcine gelatine, the inter- and intra-assays showed coefficients of variation (CVs) less than 20% and were able to detect at least 0.5 ng µg(-1) (0.05%) porcine gelatine in spiked samples. The proposed ELISA offers attractions for quality control in the EBN industry.

  10. Enzyme-Linked Immunosorbent Assay (ELISA).

    PubMed

    Konstantinou, George N

    2017-01-01

    Food allergy is a public health concern especially after recognizing its constantly increased prevalence and severity. Despite careful reading of food ingredient statements, food allergic individuals may experience reactions caused by "hidden", "masked", or "contaminated" proteins that are known major allergens. Many techniques have been developed to detect even small traces of food allergens, for clinical or laboratory purposes. Enzyme-linked immunosorbent assay (ELISA) is one of the best validated and most routinely used immunoassay in allergy research, in allergy diagnosis in allergy-related quality control in various industries. Although as a technique it has been implemented for the last 45 years, the evolution in biochemistry allowed the development of ultrasensitive ELISA variations that are capable of measuring quantities in the scale of picograms, rendering ELISA attractive, robust, and very famous.

  11. [Detecting the markers of HIV infection with the new enzyme immunoassay diagnostic kit "DS-EIA-HIV-AB-AG-SPECTRUM" at the laboratories of AIDS prevention and control centers in the Volga Federal District].

    PubMed

    Ivanova, N I; Peksheva, O Iu

    2009-03-01

    A possibility of simultaneously detecting specific antibodies to HIV-1 and HIV-2 by enzyme immunoassay (EIA) at lower concentrations than those by immunoblotting (IB), and well as an additional possibility of earlier diagnosis of HIV infection, by identifying the HIV-1 antigen p24 lay the foundation of the "DS-EIA-HIV-AB-AG-SPECTRUM" test system made by OOO "Research-and-Production Association "Diagnosticheskiye Sistemy" (Diagnostic Systems). These peculiarities were compared with those of IB at a number of laboratories of AIDS prevention and control centers in the Volga Federal District, by using native serum/plasma samples and a specially designed control panel. The analysis of the conducted studies to identify HIV-1 and HIV-2 antibodies and HIV-1 antigen p24 in 65 plasma/serum samples in the "DS-EIA-HIV-AB-AG-SPECTRUM" and "LIA-HIV-1/2" (OOO "Niarmedik plus") test systems while confirming the positive result indicated agreement in 57 (87.7%) cases. The diagnostic possibilities of the "DS-EIA-HIV-AB-AG-SPECTRUM" test system versus the "New Lav-Blot I" one to make a laboratory diagnosis of HIV infection were studied. Irrefragable answers as to the availability of HIV-1 markers in the study serum samples on the enciphered panel were provided by IB in 73.3% of cases and EIA in 92%.

  12. Validation of an enzyme-immunoassay for the non-invasive monitoring of faecal testosterone metabolites in male cheetahs (Acinonyx jubatus).

    PubMed

    Pribbenow, Susanne; Wachter, Bettina; Ludwig, Carsten; Weigold, Annika; Dehnhard, Martin

    2016-03-01

    In mammals, the sex hormone testosterone is the major endocrine variable to objectify testicular activity and thus reproductive function in males. Testosterone is involved in the development and function of male reproductive physiology and sex-related behaviour. The development of a reliable androgen enzyme-immunoassay (EIA) to monitor faecal testosterone metabolites (fTM) is a powerful tool to non-invasively assess the gonadal status of males. We validated an epiandrosterone EIA for male cheetahs by performing a testosterone radiometabolism study followed by high-performance liquid chromatography (HPLC) analyses and excluding possible cross-reactivities with androgenic metabolites not derived from testosterone metabolism. The physiological and biological relevance of the epiandrosterone EIA was validated by demonstrating (1) a significant increase in fTM concentrations within one day in response to a testosterone injection, (2) a significant increase in fTM concentrations within one day in response to a gonadotropin-releasing hormone (GnRH) injection, which failed following a placebo injection, and (3) significant differences in fTM concentrations between adult male and adult female cheetahs and between adult and juvenile male cheetahs of a free-ranging population. Finally, we demonstrated stability of fTM concentrations measured in faecal samples exposed to ambient temperatures up to 72h. Our results clearly demonstrate that the epiandrosterone EIA is a reliable non-invasive method to monitor testicular activity in male cheetahs. Copyright © 2016 Elsevier Inc. All rights reserved.

  13. ELISA analysis of soybean trypsin inhibitors in processed foods.

    PubMed

    Brandon, D L; Bates, A H; Friedman, M

    1991-01-01

    Soybean proteins are widely used in human foods in a variety of forms, including infant formulas, flour, protein concentrates, protein isolates, soy sauces, textured soy fibers, and tofu. The presence of inhibitors of digestive enzymes in soy proteins impairs the nutritional quality and possibly the safety of soybeans and other legumes. Processing, based on the use of heat or fractionation of protein isolates, does not completely inactivate or remove these inhibitors, so that residual amounts of inhibitors are consumed by animals and humans. New monoclonal antibody-based immunoassays can measure low levels of the soybean Kunitz trypsin inhibitor (KTI) and the Bowman-Birk trypsin and chymotrypsin inhibitor (BBI) and the Bowman-Birk foods. The enzyme-linked immunosorbent assay (ELISA) was used to measure the inhibitor content of soy concentrates, isolates, and flours, both heated and unheated; a commercial soy infant formula; KTI and BBI with rearranged disulfide bonds; browning products derived from heat-treatment of KTI with glucose and starch; and KTI exposed to high pH. The results indicate that even low inhibitor isolates contain significant amounts of specific inhibitors. Thus, infants on soy formula consume about 10 mg of KTI plus BBI per day. The immunoassays complement the established enzymatic assays of trypsin and chymotrypsin inhibitors, and have advantages in (a) measuring low levels of inhibitors in processed foods; and (b) differentiating between the Kunitz and Bowman-Birk inhibitors. The significance of our findings for food safety are discussed.

  14. Bacterial Expression of a Single-Chain Variable Fragment (scFv) Antibody against Ganoderic Acid A: A Cost-Effective Approach for Quantitative Analysis Using the scFv-Based Enzyme-Linked Immunosorbent Assay.

    PubMed

    Yusakul, Gorawit; Nuntawong, Poomraphie; Sakamoto, Seiichi; Ratnatilaka Na Bhuket, Pahweenvaj; Kohno, Toshitaka; Kikkawa, Nao; Rojsitthisak, Pornchai; Shimizu, Kuniyoshi; Tanaka, Hiroyuki; Morimoto, Satoshi

    2017-01-01

    Due to the highly specific binding between an antibody and its target, superior analytical performances was obtained by immunoassays for phytochemical analysis over conventional chromatographic techniques. Here, we describe a simple method for producing a functional single-chain variable fragment (scFv) antibody against ganoderic acid A (GAA), a pharmacologically active metabolite from Ganoderma lingzhi. The Escherichia coli BL21(DE3) strain produced a large amount of anti-GAA scFv. However, in vitro refolding steps, which partially recovered the reactivity of the scFv, were required. Interestingly, the functional scFv was expressed as a soluble and active form in the cytoplasm of an engineered E. coli SHuffle ® strain. Purified anti-GAA scFv, which yielded 2.56 mg from 1 L of culture medium, was obtained from simple and inexpensive procedures for expression and purification. The anti-GAA scFv-based indirect competitive enzyme-linked immunosorbent assay (icELISA) exhibited high sensitivity (linearity: 0.078-1.25 µg/mL) with precision (CV: ≤6.20%) and reliability (recovery: 100.1-101.8%) for GAA determination. In summary, the approach described here is an inexpensive, simple, and efficient expression system that extends the application of anti-GAA scFv-based immunoassays. In addition, when in vitro refolding steps can be skipped, the cost and complexity of scFv antibody production can be minimized.

  15. High Seroprevalence of Toxoplasma Gondii Infection in Female Sex Workers: A Case-Control Study

    PubMed Central

    Alvarado-Esquivel, Cosme; Sánchez-Anguiano, Luis Francisco; Hernández-Tinoco, Jesús; Arreola-Cháidez, Emilio; López, Juan; Salcido-Meraz, Karla Itzel; Estrada-Martínez, Sergio; Navarrete-Flores, José Antonio; Pérez-Álamos, Alma Rosa; Hernández-Ochoa, Marcia; Rábago-Sánchez, Elizabeth; Liesenfeld, Oliver

    2015-01-01

    Through an age- and sex-matched case-control study, we sought to determine whether female sex workers have an increased risk of Toxoplasma gondii exposure and to determine the sociodemographic, work, clinical, and behavioral characteristics of these workers associated with T. gondii exposure. Female workers (n = 136) and controls (n = 272) were examined with enzyme-linked immunoassays (EIA) for the presence of anti-Toxoplasma IgG and IgM antibodies. IgM positive sera were additionally tested with enzyme linked-fluorescence immunoassay (ELFA). Anti-T. gondii IgG antibodies were found in 21 (15.44%) of 136 cases and in 10 (3.67%) of 272 controls (OR = 4.05; 95% CI: 1.84–8.89; P = 0.0001). Anti-T. gondii IgG levels higher than 150 IU/ml were found in 13 (9.6%) of 136 cases and in 8 (2.9%) of 272 controls (P = 0.007). Anti-T. gondii IgM antibodies were found in two cases and in six controls by EIA, but all were negative by ELFA. T. gondii seropositivity was associated with being born out of Durango State (OR = 10.47; 95% CI: 2.9–36.8; P < 0.01), injuries during sex work (OR = 6.30; 95% CI: 1.1–33.7; P = 0.03), and soil contact (OR = 4.11; 95% CI: 1.2–14.0; P = 0.02). This is the first report of an association of T. gondii infection and female sex workers. PMID:26716017

  16. Detection of Total Ergot Alkaloids in Cereal Flour and in Bread by a Generic Enzyme Immunoassay Method.

    PubMed

    Gross, Madeleine; Curtui, Valeriu; Usleber, Ewald

    2018-05-01

    Four sets of polyclonal antibodies against ergot alkaloids ergometrine, ergotamine, α-ergocryptine, and ergocornine were produced and characterized in a competitive direct or indirect enzyme immunoassay (EIA). Standard curve LODs were 0.03 ng/mL (ergometrine EIA) to 2.0 ng/mL (ergocornine EIA). Three EIAs were highly specific, whereas the ergometrine EIA had a broad specificity pattern and reacted, albeit weakly, with all seven major ergot alkaloids and their epimeric forms. Using the ergometrine EIA, a generic test system was established in which total ergot alkaloids are quantified by a standard curve for a toxin mixture composed of three alkaloids that matched the ergot alkaloid composition in naturally contaminated rye and wheat products. Sample extraction with acetonitrile-phosphate-buffered saline at pH 6.0 without further cleanup was sufficient for EIA analysis. The LODs for total ergot alkaloids were 20 ng/g in rye and wheat flour and 14 ng/g in bread. Recoveries were 85-110% (RSDs of 0.1-11.7%) at a concentration range of 50-1000 ng/g. The total ergot alkaloid EIA was validated by comparison with HPLC-fluorescence detection. Although some under- and overestimation by the total ergot alkaloid EIA was observed, it was suitable for the reliable identification of positive samples at 10-20 ng/g and for the determination of total ergot alkaloids in a concentration range between 100 and 1000 ng/g.

  17. Evaluation of the chemiluminescent enzyme immunoassay system for the measurement of testosterone in the serum and whole blood of stallions

    PubMed Central

    TOISHI, Yuko; TSUNODA, Nobuo; NAGATA, Shun-ichi; KIRISAWA, Rikio; NAGAOKA, Kentaro; WATANABE, Gen; YANAGAWA, Yojiro; KATAGIRI, Seiji; TAYA, Kazuyoshi

    2017-01-01

    Testosterone (T) concentration is a useful indicator of reproductive function in male animals. However, T concentration is not usually measured in veterinary clinics, partly due to the unavailability of reliable and rapid assays for animal samples. In this study, a rapid chemiluminescent enzyme immunoassay system (CLEIA system) that was developed for the measurement of T concentration in humans use was validated for stallion blood samples. First, serum T concentrations were measured using the CLEIA system and compared with those measured by a fluoroimmunoassay that has been validated for use in stallions. The serum T concentrations measured by the two methods were highly correlated (r = 0.9865, n = 56). Second, to validate the use of whole blood as assay samples, T concentrations in whole blood and in the serum were measured by the CLEIA system. T concentrations in both samples were highly correlated (r = 0.9665, n = 64). Finally, to evaluate the practical value of the CLEIA system in clinical settings, T concentrations were measured in three stallions with reproductive abnormalities after the administration of human chorionic gonadotropin (hCG). Two stallions with small or absent testes in the scrotum showed an increase in T production in response to hCG administration and one stallion with seminoma did not. In conclusion, the CLEIA system was found to be a rapid and reliable tool for measuring T concentrations in stallions and may improve reproductive management in clinical settings and in breeding studs. PMID:29129877

  18. Colloidal nanomaterial-based immunoassay.

    PubMed

    Teste, Bruno; Descroix, Stephanie

    2012-06-01

    Nanomaterials have been widely developed for their use in nanomedicine, especially for immunoassay-based diagnosis. In this review we focus on the use of nanomaterials as a nanoplatform for colloidal immunoassays. While conventional heterogeneous immunoassays suffer from mass transfer limitations and consequently long assay time, colloidal immunosupports allow target capture in the entire volume, thus speeding up reaction kinetics and shortening assay time. Owing to their wide range of chemical and physical properties, nanomaterials are an interesting candidate for immunoassay development. The most popular colloidal nanomaterials for colloidal immunoassays will be discussed, as well as their influence on immune reactions. Recent advances in nanomaterial applications for different formats of immunoassays will be reported, such as nanomaterial-based indirect immunoassays, optical-based agglutination immunoassays, resonance energy transfer-based immunoassays and magnetic relaxation-based immunoassays. Finally, the future of using nanomaterials for homogeneous immunoassays dedicated to clinical diagnosis will be discussed.

  19. New fluorimetric assay of horseradish peroxidase using sesamol as substrate and its application to EIA.

    PubMed

    Arakawa, Hidetoshi; Nakabayashi, Shigeo; Ohno, Ken-Ichi; Maeda, Masako

    2012-04-01

    Horseradish peroxidase (HRP) is generally used as a label enzyme in enzyme immunoassay (EIA). The procedure used for HRP detection in EIA is critical for sensitivity and precision. This paper describes a novel fluorimetric assay for horseradish peroxidase (HRP) using sesamol as substrate. The principle of the assay is as follow: sesamol (3,4-methylenedioxy phenol) is reacted enzymatically in the presence of hydrogen peroxide to produce dimeric sesamol. The dimer is fluorescent and can be detected sensitively at ex. 347 nm, em. 427 nm. The measurable range of HRP was 1.0×10 -18 to 1.0×10 -15  mol/assay, with a detection limit of 1.0×10 -18  mol/assay. The coefficient of variation (CV, n =8) was examined at each point on the standard curve, with a mean CV percentage of 3.8%. This assay system was applied to thyroid stimulating hormone (TSH) EIA using HRP as the label enzyme.

  20. Dye sensitized photoelectrochemical immunosensor for the tumor marker CEA by using a flower-like 3D architecture prepared from graphene oxide and MoS2.

    PubMed

    Song, Kaijing; Ding, Chuanmin; Zhang, Bing; Chang, Honghong; Zhao, Zhihuan; Wei, Wenlong; Wang, Junwen

    2018-06-01

    The authors describe a dye-sensitized photoelectrochemical immunoassay for the tumor marker carcinoembryonic antigen (CEA). The method employs the rhodamine dye Rh123 with red color and absorption maximum at 500 nm for spectral sensitization, and a 3D nanocomposite prepared from graphene oxide and MoS 2 acting as the photoelectric conversion layer. The nanocomposite with flower-like 3D architectures was characterized by transmission electron microscopy, scanning electron microscopy, X-ray powder diffraction, and UV-vis diffuse reflectometry. A photoelectrochemical sandwich immunoassay was developed that is based on the use of the nanocomposite and based on the specific binding of antibody and antigen, and by using a secondary antibody labeled with Rh123 and CdS (Ab 2 -Rh123@CdS). Under optimal conditions and at a typical working voltage of 0 V (vs. Hg/HgCl 2 ), the photocurrent increases linearly 10 pg mL -1 to 80 ng mL -1 CEA concentration range, with a 3.2 pg mL -1 detection limit. Graphical abstract Flower-like GO-MoS 2 complex with high efficiency of electron transport was synthesized to construct photoelectrochemical platform. The sandwich-type immunoassay was built on this platform based on specific binding of antigen and antibody. Carcinoembryonic antigen in sample was detected sensitively by using sensitization of rhodamine dye Rh123 as signal amplification strategy.

  1. Development of a colony lift immunoassay to facilitate rapid detection and quantification of Escherichia coli O157:H7 from agar plates and filter monitor membranes.

    PubMed

    Ingram, D T; Lamichhane, C M; Rollins, D M; Carr, L E; Mallinson, E T; Joseph, S W

    1998-07-01

    E. coli O157:H7 is a food-borne adulterant that can cause hemorrhagic ulcerative colitis and hemolytic uremic syndrome. Faced with an increasing risk of foods contaminated with E. coli O157:H7, food safety officials are seeking improved methods to detect and isolate E. coli O157:H7 in hazard analysis and critical control point systems in meat- and poultry-processing plants. A colony lift immunoassay was developed to facilitate the positive identification and quantification of E. coli O157:H7 by incorporating a simple colony lift enzyme-linked immunosorbent assay with filter monitors and traditional culture methods. Polyvinylidene difluoride (PVDF) membranes (Millipore, Bedford, Mass.) were prewet with methanol and were used to make replicates of every bacterial colony on agar plates or filter monitor membranes that were then reincubated for 15 to 18 h at 36 +/- 1 degree C, during which the colonies not only remained viable but were reestablished. The membranes were dried, blocked with blocking buffer (Kirkegaard and Perry Laboratories [KPL], Gaithersburg, Md.), and exposed for 7 min to an affinity-purified horseradish peroxidase-labeled goat anti-E. coli O157 antibody (KPL). The membranes were washed, exposed to a 3,3',5,5'-tetramethylbenzidine membrane substrate (TMB; KPL) or aminoethyl carbazole (AEC; Sigma Chemical Co., St. Louis, Mo.), rinsed in deionized water, and air dried. Colonies of E. coli O157:H7 were identified by either a blue (via TMB) or a red (via AEC) color reaction. The colored spots on the PVDF lift membrane were then matched to their respective parent colonies on the agar plates or filter monitor membranes. The colony lift immunoassay was tested with a wide range of genera in the family Enterobacteriaceae as well as different serotypes within the E. coli genus. The colony lift immunoassay provided a simple, rapid, and accurate method for confirming the presence of E. coli O157:H7 colonies isolated on filter monitors or spread plates by traditional culture methods. An advantage of using the colony lift immunoassay is the ability to test every colony serologically on an agar plate or filter monitor membrane simultaneously for the presence of the E. coli O157 antigen. This colony lift immunoassay has recently been successfully incorporated into a rapid-detection, isolation, and quantification system for E. coli O157:H7, developed in our laboratories for retail meat sampling.

  2. Development of a Colony Lift Immunoassay To Facilitate Rapid Detection and Quantification of Escherichia coli O157:H7 from Agar Plates and Filter Monitor Membranes

    PubMed Central

    Ingram, David T.; Lamichhane, Chinta M.; Rollins, David M.; Carr, Lewis E.; Mallinson, Edward T.; Joseph, Sam W.

    1998-01-01

    E. coli O157:H7 is a food-borne adulterant that can cause hemorrhagic ulcerative colitis and hemolytic uremic syndrome. Faced with an increasing risk of foods contaminated with E. coli O157:H7, food safety officials are seeking improved methods to detect and isolate E. coli O157:H7 in hazard analysis and critical control point systems in meat- and poultry-processing plants. A colony lift immunoassay was developed to facilitate the positive identification and quantification of E. coli O157:H7 by incorporating a simple colony lift enzyme-linked immunosorbent assay with filter monitors and traditional culture methods. Polyvinylidene difluoride (PVDF) membranes (Millipore, Bedford, Mass.) were prewet with methanol and were used to make replicates of every bacterial colony on agar plates or filter monitor membranes that were then reincubated for 15 to 18 h at 36 ± 1°C, during which the colonies not only remained viable but were reestablished. The membranes were dried, blocked with blocking buffer (Kirkegaard and Perry Laboratories [KPL], Gaithersburg, Md.), and exposed for 7 min to an affinity-purified horseradish peroxidase-labeled goat anti-E. coli O157 antibody (KPL). The membranes were washed, exposed to a 3,3′,5,5′-tetramethylbenzidine membrane substrate (TMB; KPL) or aminoethyl carbazole (AEC; Sigma Chemical Co., St. Louis, Mo.), rinsed in deionized water, and air dried. Colonies of E. coli O157:H7 were identified by either a blue (via TMB) or a red (via AEC) color reaction. The colored spots on the PVDF lift membrane were then matched to their respective parent colonies on the agar plates or filter monitor membranes. The colony lift immunoassay was tested with a wide range of genera in the family Enterobacteriaceae as well as different serotypes within the E. coli genus. The colony lift immunoassay provided a simple, rapid, and accurate method for confirming the presence of E. coli O157:H7 colonies isolated on filter monitors or spread plates by traditional culture methods. An advantage of using the colony lift immunoassay is the ability to test every colony serologically on an agar plate or filter monitor membrane simultaneously for the presence of the E. coli O157 antigen. This colony lift immunoassay has recently been successfully incorporated into a rapid-detection, isolation, and quantification system for E. coli O157:H7, developed in our laboratories for retail meat sampling. PMID:9665968

  3. Validation of a Commercially Available Enzyme ImmunoAssay for the Determination of Oxytocin in Plasma Samples from Seven Domestic Animal Species.

    PubMed

    Bienboire-Frosini, Cecile; Chabaud, Camille; Cozzi, Alessandro; Codecasa, Elisa; Pageat, Patrick

    2017-01-01

    The neurohormone oxytocin (OT) has a broad range of behavioral effects in mammals. It modulates a multitude of social behaviors, e.g., affiliative and sexual interactions. Consequently, the OT role in various animal species is increasingly explored. However, several issues have been raised regarding the peripheral OT measurement. Indeed, various methods have been described, leading to assay discrepancies and inconsistent results. This highlights the need for a recognized and reliable method to measure peripheral OT. Our aim was to validate a method combining a pre-extraction step, previously demonstrated as essential by several authors, and a commercially available enzyme immunoassay (EIA) for OT measurement, using plasma from seven domestic species (cat, dog, horse, cow, pig, sheep, and goat). The Oxytocin EIA kit (EnzoLifeSciences) was used to assay the solid-phase extracted samples following the manufacturer's instructions with slight modifications. For all species except dogs and cats, concentration factors were applied to work above the kit's sensitivity (15 pg/ml). To validate the method, the following performance characteristics were evaluated using Validation Samples (VS) at various concentrations in each species: extraction efficiency via spiking tests and intra- and inter-assay precision, allowing for the calculation of total errors. Parallelism studies to assess matrix effects could not be performed because of too low basal concentrations. Quantification ranges and associated precision profiles were established to account for the various OT plasma concentrations in each species. According to guidelines for bioanalytical validation of immunoassays, the measurements were sufficiently precise and accurate in each species to achieve a total error ≤30% in each VS sample. In each species, the inter-assay precision after 3 runs was acceptable, except in low concentration samples. The linearity under dilution of dogs and cats' samples was verified. Although matrix effects assessments are lacking, our results indicate that OT plasma levels can reliably be measured in several domestic animal species by the method described here. Studies involving samples with low OT plasma concentrations should pay attention to reproducibility issues. This work opens new perspectives to reliably study peripheral OT in a substantial number of domestic animal species in various behavioral contexts.

  4. Ballistic Motion of Enzymes that Catalyze Highly Exothermic Reactions

    NASA Astrophysics Data System (ADS)

    Tsekouras, Konstantinos; Pressé, Steve

    Recently we proposed that the experimentally observed enhanced diffusion of enzymes catalyzing highly exothermic reactions is a consequence of their mechanism for dissipating reaction energy. More specifically, we proposed that reaction energy spreads out from the reaction site in the form of an acoustic wave which causes the enzyme to asymmetrically deform into the solvent. The solvent reaction propels the enzyme. However, it has been noted that in water, high viscosity should reduce enzyme momentum to zero within a few ps, so any diffusion increase should not be observable. Here we provide a model explaining how small volumetric expansions of biomolecules inside water may cause fluid compression that in turn creates regions of low fluid density around the biomolecule. We then investigate the dynamics of the biomolecule in the presence of these perturbations.

  5. Immunoassay or LC-MS/MS for the measurement of salivary cortisol in children?

    PubMed

    Bae, Yoon Ju; Gaudl, Alexander; Jaeger, Sonia; Stadelmann, Stephanie; Hiemisch, Andreas; Kiess, Wieland; Willenberg, Anja; Schaab, Michael; von Klitzing, Kai; Thiery, Joachim; Ceglarek, Uta; Döhnert, Mirko; Kratzsch, Juergen

    2016-05-01

    Dysregulation of the adrenal cortex has been assessed with measurement of salivary cortisol. So far salivary cortisol is routinely measured with immunoassay (IA). However, liquid chromatography-tandem mass spectrometry (MS) is known to offer better specificity. We compared the concentrations of salivary cortisol measured by MS and IA at basal and stress induced conditions and evaluated reasons for the difference in method-dependent cortisol results. Saliva samples (n=2703) were collected from 169 children (age range: 8-14 years; 81 healthy children; 55 with internalizing and 33 with externalizing disorders) under circadian conditions and during the Trier Social Stress Test for Children (TSST-C). Biochemical analyses were performed with MS for cortisol and cortisone, IA (IBL, RE62011) for cortisol, and enzyme kinetic assay for α-amylase. MS and IA showed mostly comparable results for circadian activity and TSST-C response with similar statistical power. However, IA measured cortisol concentrations about 2.39-fold higher than MS. We found that this difference in measured values between MS and IA was mainly due to different standardization of IA compared to MS. In addition, at cortisol IA concentration below 5 nmol/L, cross-reactivity with cortisone was found to contribute to the lower concordance between MS and IA. Immunoassay and LC-MS/MS were largely comparable in the interpretation of salivary cortisol dynamics in stress research. But the IA method revealed a restricted accuracy in the measuring range below 5 nmol/L.

  6. Prospective evaluation of a rapid nanoparticle-based lateral flow immunoassay (STic Expert(®) HIT) for the diagnosis of heparin-induced thrombocytopenia.

    PubMed

    Leroux, Dorothée; Hezard, Nathalie; Lebreton, Aurélien; Bauters, Anne; Suchon, Pierre; de Maistre, Emmanuel; Biron, Christine; Huisse, Marie-Genevieve; Ternisien, Catherine; Voisin, Sophie; Gruel, Yves; Pouplard, Claire

    2014-09-01

    A rapid lateral flow immunoassay (LFIA) (STic Expert(®) HIT), recently developed for the diagnosis of heparin-induced thrombocytopenia (HIT), was evaluated in a prospective multicentre cohort of 334 consecutive patients. The risk of HIT was estimated by the 4Ts score as low, intermediate and high in 28·7%, 61·7% and 9·6% of patients, respectively. Definite HIT was diagnosed in 40 patients (12·0%) with positive results on both enzyme-linked immunosorbent assay (Asserachrom(®) HPIA IgG) and serotonin release assay. The inter-reader reproducibility of results obtained was excellent (kappa ratio > 0·9). The negative predictive value of LFIA with plasma samples was 99·6% with a negative likelihood ratio (LR) of 0·03, and was comparable to those of the particle gel immunoassay (H/PF4-PaGIA(®) ) performed in 124 cases. Positive predictive value and positive LR were 44·4% and 5·87, respectively, and the results were similar for serum samples. The probability of HIT in intermediate risk patients decreased from 11·2% to 0·4% when the LFIA result was negative and increased to 42·5% when it was positive. In conclusion, the STic Expert(®) HIT combined with the 4Ts score is a reliable tool to rule out the diagnosis of HIT. © 2014 John Wiley & Sons Ltd.

  7. Development and Validation of a Fluorescent Multiplexed Immunoassay for Measurement of Transgenic Proteins in Cotton (Gossypium hirsutum).

    PubMed

    Yeaman, Grant R; Paul, Sudakshina; Nahirna, Iryna; Wang, Yongcheng; Deffenbaugh, Andrew E; Liu, Zi Lucy; Glenn, Kevin C

    2016-06-22

    In order to provide farmers with better and more customized alternatives to improve yields, combining multiple genetically modified (GM) traits into a single product (called stacked trait crops) is becoming prevalent. Trait protein expression levels are used to characterize new GM products and establish exposure limits, two important components of safety assessment. Developing a multiplexed immunoassay capable of measuring all trait proteins in the same sample allows for higher sample throughput and savings in both time and expense. Fluorescent (bead-based) multiplexed immunoassays (FMI) have gained wide acceptance in mammalian research and in clinical applications. In order to facilitate the measurement of stacked GM traits, we have developed and validated an FMI assay that can measure five different proteins (β-glucuronidase, neomycin phosphotransferase II, Cry1Ac, Cry2Ab2, and CP4 5-enolpyruvyl-shikimate-3-phosphate synthase) present in cotton leaf from a stacked trait product. Expression levels of the five proteins determined by FMI in cotton leaf tissues have been evaluated relative to expression levels determined by enzyme-linked immunosorbent assays (ELISAs) of the individual proteins and shown to be comparable. The FMI met characterization requirements similar to those used for ELISA. Therefore, it is reasonable to conclude that FMI results are equivalent to those determined by conventional individual ELISAs to measure GM protein expression levels in stacked trait products but with significantly higher throughput, reduced time, and more efficient use of resources.

  8. Detection of the Antimicrobial Triclosan in Environmental Samples by Immunoassay

    PubMed Central

    Ahn, Ki Chang; Ranganathan, Anupama; Bever, Candace S.; Hwang, Sung Hee; Holland, Erika B.; Morisseau, Kevin; Pessah, Isaac N.; Hammock, Bruce D.; Gee, Shirley J.

    2016-01-01

    A sensitive, competitive enzyme-linked immunosorbent assay (ELISA) for the detection of the antimicrobial triclosan (TCS; 2,4,4’-trichloro-2’-hydroxydiphenyl ether) was developed. Novel immunizing haptens were synthesized by derivatizing at the 4-Cl position of the TCS molecule. Compounds derived from substitutions at 4’-Cl and that replaced the 2’–OH with a –Cl were designed as unique coating antigen haptens. Polyclonal rabbit antisera were screened against the coating antigen library in order to identify combinations of immunoreagents resulting in the most sensitive assays. The most sensitive assay identified was one utilizing antiserum #1155 and a heterologous competitive hapten where the 2’–OH group was substituted with a Cl. An IC50 value and the detection range for TCS in assay buffer were 1.19 and 0.21–6.71 μg/L, respectively. The assay was selective for TCS, providing low cross-reactivity (< 5%) to the major metabolites of TCS and to brominated diphenyl ether-47. A second assay utilizing a competitive hapten containing Br instead of Cl substitutions was broadly selective for both brominated and chlorinated diphenylethers. Using the most sensitive assay combination, TCS concentrations were measured in water samples following dilution. Biosolid samples were analyzed following dilution of a simple solvent extract. The immunoassay results were similar to those determined by LC-MS/MS. This immunoassay can be used as a rapid and convenient tool to screen for human and environmental exposure. PMID:26937944

  9. Detection of the Antimicrobial Triclosan in Environmental Samples by Immunoassay.

    PubMed

    Ahn, Ki Chang; Ranganathan, Anupama; Bever, Candace S; Hwang, Sung Hee; Holland, Erika B; Morisseau, Kevin; Pessah, Isaac N; Hammock, Bruce D; Gee, Shirley J

    2016-04-05

    A sensitive, competitive enzyme-linked immunosorbent assay (ELISA) for the detection of the antimicrobial triclosan (TCS; 2,4,4'-trichloro-2'-hydroxydiphenyl ether) was developed. Novel immunizing haptens were synthesized by derivatizing at the 4-Cl position of the TCS molecule. Compounds derived from substitutions at 4'-Cl and that replaced the 2'-OH with a Cl atom were designed as unique coating antigen haptens. Polyclonal rabbit antisera were screened against the coating antigen library to identify combinations of immunoreagents resulting in the most sensitive assays. The most sensitive assay identified was one utilizing antiserum no. 1155 and a heterologous competitive hapten, where the 2'-OH group was substituted with a Cl atom. An IC50 value and the detection range for TCS in assay buffer were 1.19 and 0.21-6.71 μg/L, respectively. The assay was selective for TCS, providing low cross-reactivity (<5%) to the major metabolites of TCS and to brominated diphenyl ether-47. A second assay utilizing a competitive hapten containing Br instead of Cl substitutions was broadly selective for both brominated and chlorinated diphenylethers. Using the most sensitive assay combination, we measured TCS concentrations in water samples following dilution. Biosolid samples were analyzed following the dilution of a simple solvent extract. The immunoassay results were similar to those determined by LC-MS/MS. This immunoassay can be used as a rapid and convenient tool to screen for human and environmental exposure.

  10. High-contrast grating resonators for label-free detection of disease biomarkers

    PubMed Central

    Sun, Tianbo; Kan, Shu; Marriott, Gerard; Chang-Hasnain, Connie

    2016-01-01

    A label-free optical biosensor is described that employs a silicon-based high-contrast grating (HCG) resonator with a spectral linewidth of ~500 pm that is sensitive to ligand-induced changes in surface properties. The device is used to generate thermodynamic and kinetic data on surface-attached antibodies with their respective antigens. The device can detect serum cardiac troponin I, a biomarker of cardiac disease to 100 pg/ml within 4 mins, which is faster, and as sensitive as current enzyme-linked immuno-assays for cTnI. PMID:27265624

  11. Production of a Suitable Antibody and an Enzyme Immunoassay Kit for the Field Detection of T-2 Toxin

    DTIC Science & Technology

    1983-10-25

    Known to naturally occur on plants including food products. £> These trichothecenes are highly toxic to eukaryotic cells and are anong the most...Activities and Detection of Naturally O* Occurring 12,13-Epoxy-9-Trichothecenes," Clin. Tbxicol., 5, pp. 495-515. E* 3. Y. Ueno, M. Makajima, K. Sakei, K...North-Holland, N.Y. -13- i 6. S. V. Pathre, C. J. Mirocha (1977) Assay Methods for Trichothecenes and J; Review of Their Natural Occurence in: J. V

  12. High-contrast grating resonators for label-free detection of disease biomarkers

    NASA Astrophysics Data System (ADS)

    Sun, Tianbo; Kan, Shu; Marriott, Gerard; Chang-Hasnain, Connie

    2016-06-01

    A label-free optical biosensor is described that employs a silicon-based high-contrast grating (HCG) resonator with a spectral linewidth of ~500 pm that is sensitive to ligand-induced changes in surface properties. The device is used to generate thermodynamic and kinetic data on surface-attached antibodies with their respective antigens. The device can detect serum cardiac troponin I, a biomarker of cardiac disease to 100 pg/ml within 4 mins, which is faster, and as sensitive as current enzyme-linked immuno-assays for cTnI.

  13. Chicken IgY-Fc antibody elicited in a rabbit as first coat on frosted glass beads in immunoassays.

    PubMed

    Polson, A

    1993-07-01

    The observation of Esteves and Binaghi that the Fc moieties of mammalian IgG are antigenically similar but antigenically unrelated to the Fc fraction of chicken IgG (IgY) was usefully applied in enzyme linked immuno-sorbent assay (ELISA). In this communication its use in ELISA of two plant viruses viz. tobacco mosaic virus (common strain) and grape vine A virus is illustrated. Frosted glass beads were used as reagent carriers and the reactions were conducted in the wells of multi-titre plates.

  14. SOME CHARACTERISTICS OF THE ORAL CAVITY AND TEETH OF COSMONAUTS ON MISSIONS TO THE INTERNATIONAL SPACE STATION.

    PubMed

    Ilyin, V K; Shumilina, G A; Solovieva, Z O; Nosovsky, A M; Kaminskaya, E V

    Earlier studies were furthered by examination of parodentium anaerobic microbiota and investigation of gingival liquid immunological factors in space flight. Immunoglobulins were measured using the .enzyme immunoassay (EM). The qualitative content of keya parodentium pathogens is determined with state-of-the-art molecular biology technologies such as the polymerase chain reaction. Statistical data processing was performed using the principle component analysis and ensuing standard statistical analysis. Thereupon, recommendations on cosmonaut's oral and dental hygiene during space mission were developed.

  15. Repeated injections of nicergoline increase the nerve growth factor level in the aged rat brain.

    PubMed

    Nishio, T; Sunohara, N; Furukawa, S; Akiguchi, I; Kudo, Y

    1998-03-01

    We studied whether nicergoline, clinically active in chronic cerebrovascular insufficiency, influences nerve growth factor (NGF) levels in the rat brain. In young Fischer rats, repeated intraperitoneal injections of nicergoline (0.3 and 1.0 mg/kg body weight) did not show any effects on frontal NGF contents determined by a highly sensitive enzyme immunoassay. In aged rats, 22-month-old, however, repeated injections of nicergoline (1.0 mg/kg body weight) induced a significant increase in the NGF level in the frontal region.

  16. pH-dependent immobilization of urease on glutathione-capped gold nanoparticles.

    PubMed

    Garg, Seema; De, Arnab; Mozumdar, Subho

    2015-05-01

    Urease is a nickel-dependent metalloenzyme that catalyzes the hydrolysis of urea to form ammonia and carbon dioxide. Although the enzyme serves a significant role in several detoxification and analytical processes, its usability is restricted due to high cost, availability in small amounts, instability, and a limited possibility of economic recovery from a reaction mixture. Hence, there is a need to develop an efficient, simple, and reliable immobilization strategy for the enzyme. In this study, the carboxyl terminated surface of glutathione-capped gold nanoparticles have been utilized as a solid support for the covalent attachment of urease. The immobilization has been carried out at different pH conditions so as to elucidate its effect on the immobilization efficiency and enzyme bioactivity. The binding of the enzyme has been quantitatively and qualitatively analyzed through techniques like ultraviolet-visible spectroscopy, intrinsic steady state fluorescence, and circular dichorism. The bioactivity of the immobilized enzyme was investigated with respect to the native enzyme under different thermal conditions. Recyclability and shelf life studies of the immobilized enzyme have also been carried out. Results reveal that the immobilization is most effective at pH of 7.4 followed by that in an acidic medium and is least in alkaline environment. The immobilized enzyme also exhibits enhance activity in comparison to the native form at physiological temperature. The immobilized urease (on gold glutathione nanoconjugates surface) can be effectively employed for biosensor fabrication, immunoassays and as an in vivo diagnostic tool in the future. © 2014 Wiley Periodicals, Inc.

  17. Widespread occurrence of low levels of alternariol in apple and tomato products, as determined by comparative immunochemical assessment using monoclonal and polyclonal antibodies.

    PubMed

    Ackermann, Yvonne; Curtui, Valeriu; Dietrich, Richard; Gross, Madeleine; Latif, Hadri; Märtlbauer, Erwin; Usleber, Ewald

    2011-06-22

    This study investigated the production of polyclonal (pAB) antibodies and the first time production of monoclonal (mAB) antibodies against the mycotoxin alternariol, and their implementation in enzyme immunoassay (EIA) for the rapid determination of alternariol in foods. Both EIAs were highly sensitive, with detection limits (IC₂₀) of 35 ± 6.9 pg/mL (mAb EIA) and 59 ± 16 pg/mL (pAb EIA). Food products (n = 109; apple and tomato products, white wine) from German retail shops were analyzed. At a detection limit of 1-2 μg/kg, alternariol at 1-13 μg/kg was found with high frequency in apple (67%) and tomato (93%) products. Tomatoes with visible signs of Alternaria infection, stored at room temperature for up to 4 weeks, contained alternariol at levels up to 50 mg/kg, as determined by EIA and HPLC-FLD. It is concluded that the alternariol immunoassays present a versatile screening tool which could facilitate food control for Alternaria toxins.

  18. Assessment of Dioxin-Like Soil Contamination in Mexico by Enzyme-Linked Immunosorbent Assay

    PubMed Central

    Nichkova, M.; Yáñez, L.; Costilla-Salazar, R.; Torres-Dosal, A.; Gee, S. J.; Hammock, B. D.; Juárez-Santacruz, L.; Díaz-Barriga, F.

    2011-01-01

    In this work, we describe the results of a preliminary soil assessment program for the detection of dioxins at different sites in Mexico performed by immunoassay. We studied five different sectors considered relevant sources of dioxins: Anaversa and Tekchem industrial areas where organochlorine pesticides were manufactured and released by accidental explosions, secondary smelters, brick kilns, and rural dwellings. In the context of the Agency for Toxic Substances and Disease Registry (ATSDR) guidelines, only the brick kilns sites can be considered as low-risk areas. The dioxin concentrations detected in the vicinity of the Anaversa and Tekchem chemical plants and secondary smelters exceed the screening level of 0.05 ppb set by the ATSDR, and therefore further site-specific studies are needed. The dioxin levels found in all soot samples from indigenous dwellings where wood is used for indoor cooking were above the evaluation level. Considering that the studied areas are representative examples of dioxin sources in less developed countries, our work demonstrates the useful application of dioxin immunoassays as a tool for dioxin screening for environmental assessment programs in developing countries. PMID:20091164

  19. Immunoreactivity of Biochemically Purified Amandin from Thermally Processed Almonds (Prunus dulcis L.).

    PubMed

    Zaffran, Valerie D; Sathe, Shridhar K

    2018-06-15

    Almond seeds were subjected to select thermal processing and amandin was purified from processed and unprocessed (control) seeds using cryoprecipitation. Amandin immunoreactivity was assessed using two murine monoclonal antibodies (mAbs)-4C10 and 4F10 detecting human IgE-relevant conformational and linear epitopes, respectively. Overall amandin immunoreactivity following thermal treatment ranged from 64.9% to 277.8% (4C10) and 81.3% to 270.3% (4F10). Except for autoclaving (121 °C, 15 psi, 30 min) and roasting (160 °C, 30 min), the tested processing conditions resulted in increased immunoreactivity as determined by mAbs 4C10 and 4F10-based enzyme-linked immunosorbent assays (ELISAs). A significant, yet not complete, reduction in immunoreactivity was caused by autoclaving (121 °C, 15 psi, 30 min) and roasting (160 °C, 30 min). Western- and dot-blot immunoassays corroborated the ELISA results, confirming amandin thermal stability. The tested immunoassays indicated amandin to be stable, regardless of the targeted epitope and the processing method that whole almond seeds were subjected to. © 2018 Institute of Food Technologists®.

  20. Peptidic β-sheet binding with Congo Red allows both reduction of error variance and signal amplification for immunoassays.

    PubMed

    Wang, Yunyun; Liu, Ye; Deng, Xinli; Cong, Yulong; Jiang, Xingyu

    2016-12-15

    Although conventional enzyme-linked immunosorbent assays (ELISA) and related assays have been widely applied for the diagnosis of diseases, many of them suffer from large error variance for monitoring the concentration of targets over time, and insufficient limit of detection (LOD) for assaying dilute targets. We herein report a readout mode of ELISA based on the binding between peptidic β-sheet structure and Congo Red. The formation of peptidic β-sheet structure is triggered by alkaline phosphatase (ALP). For the detection of P-Selectin which is a crucial indicator for evaluating thrombus diseases in clinic, the 'β-sheet and Congo Red' mode significantly decreases both the error variance and the LOD (from 9.7ng/ml to 1.1 ng/ml) of detection, compared with commercial ELISA (an existing gold-standard method for detecting P-Selectin in clinic). Considering the wide range of ALP-based antibodies for immunoassays, such novel method could be applicable to the analysis of many types of targets. Copyright © 2016 Elsevier B.V. All rights reserved.

  1. Development of flow-through and dip-stick immunoassays for screening of sulfonamide residues.

    PubMed

    Zhang, Hongyan; Zhang, Yan; Wang, Shuo

    2008-08-20

    Two formats of membrane-based competitive enzyme immunoassays (flow-through and dip-stick) have been developed for the screening of sulfonamide residues in pig muscle and milk. Membrane was coated with anti-sulfonamide antibody and a sulfonamide hapten D2-horseradish peroxidase (HRP) conjugant was used as the labeled antigen for competitive assay of sulfonamides. Visual detection limits of the flow-through or dip-stick assay were 1-5 microg L(-1) or 1-10 microg L(-1) in buffer for seven sulfonamides, respectively. Assay validation was performed using samples spiked with single sulfonamide, spiked samples were tested using the developed strip assays and results were compared with those obtained by a validated high-performance liquid chromatograph (HPLC) method. Results showed that the two strip assays were correlated well with HPLC, respectively. With assay times of 5 min (flow-through) and 15 min (dip-stick), these rapid tests could offer simple, rapid and cost-effective on-site screening tools to detect sulfonamides in pig muscle (flow-through or dip-stick) or milk (only dip-stick).

  2. Chitosan-coated polystyrene microplate for covalent immobilization of enzyme.

    PubMed

    Zhang, Yaodong; Li, Li; Yu, Caihong; Hei, Tingting

    2011-10-01

    Microplates made of polystyrene have been widely used for immunoassays. Protein molecules that have been immobilized on a hydrophobic polystyrene microplate by passive adsorption lose their activity and suffer considerable denaturation. A new chitosan-coated microplate suitable for the covalent immobilization of enzymes has been developed. The primary amino groups of chitosan were exploited for this covalent coupling of proteins. The optical transmittance of the chitosan-coated microplate, at wavelengths of 400-800 nm, was estimated to be suitable for its application in chromogenic reaction-based bioassays. The immobilization efficiency of the chitosan-coated microplate was demonstrated to be far superior to that of a conventional microplate when tested using acetylcholinesterase (AChE) and β-glucosidase as model biomolecules, and the chitosan-coated microplate may thus have potential applications in biosensing and bioreactor systems. © Springer-Verlag 2011

  3. Enzyme localization, crowding, and buffers collectively modulate diffusion-influenced signal transduction: Insights from continuum diffusion modeling

    PubMed Central

    Kekenes-Huskey, Peter M.; Eun, Changsun; McCammon, J. A.

    2015-01-01

    Biochemical reaction networks consisting of coupled enzymes connect substrate signaling events with biological function. Substrates involved in these reactions can be strongly influenced by diffusion “barriers” arising from impenetrable cellular structures and macromolecules, as well as interactions with biomolecules, especially within crowded environments. For diffusion-influenced reactions, the spatial organization of diffusion barriers arising from intracellular structures, non-specific crowders, and specific-binders (buffers) strongly controls the temporal and spatial reaction kinetics. In this study, we use two prototypical biochemical reactions, a Goodwin oscillator, and a reaction with a periodic source/sink term to examine how a diffusion barrier that partitions substrates controls reaction behavior. Namely, we examine how conditions representative of a densely packed cytosol, including reduced accessible volume fraction, non-specific interactions, and buffers, impede diffusion over nanometer length-scales. We find that diffusion barriers can modulate the frequencies and amplitudes of coupled diffusion-influenced reaction networks, as well as give rise to “compartments” of decoupled reactant populations. These effects appear to be intensified in the presence of buffers localized to the diffusion barrier. These findings have strong implications for the role of the cellular environment in tuning the dynamics of signaling pathways. PMID:26342355

  4. Multicenter comparison of levels of antibody to the Neisseria meningitidis group A capsular polysaccharide measured by using an enzyme-linked immunosorbent assay.

    PubMed Central

    Carlone, G M; Frasch, C E; Siber, G R; Quataert, S; Gheesling, L L; Turner, S H; Plikaytis, B D; Helsel, L O; DeWitt, W E; Bibb, W F

    1992-01-01

    There is no standard immunoassay for evaluating immune responses to meningococcal vaccines. We developed an enzyme-linked immunosorbent assay to measure total levels of antibody to Neisseria meningitidis group A capsular polysaccharide. Five laboratories measured the antibody levels in six paired pre- and postvaccination serum samples by using the enzyme-linked immunosorbent assay. Methylated human serum albumin was used to bind native group A polysaccharide to microtiter plate surfaces. The between-laboratory coefficients of variation for pre- and postvaccination sera had ranges of 31 to 91 and 17 to 31, respectively. The mean laboratory coefficients of variation for pre- and postvaccination sera, respectively, were 17 and 11 (Molecular Biology Laboratory, Centers for Disease Control), 12 and 15 (Immunodiagnostic Methods Laboratory, Centers for Disease Control), 22 and 19 (Dana-Farber Cancer Institute), 38 and 38 (Bacterial Polysaccharide Laboratory, U.S. Food and Drug Administration), and 11 and 10 (Praxis Biologics, Inc.). Standardization of this enzyme-linked immunosorbent assay should allow interlaboratory comparison of meningococcal vaccine immunogenicity, thus providing a laboratory-based assessment tool for evaluating meningococcal vaccines. PMID:1734048

  5. Development and validation of a sensitive enzyme immunoassay (EIA) for blood plasma cortisol in female cattle, buffaloes, and goats.

    PubMed

    Yadav, R; Mohan, K; Kumar, V; Sarkar, M; Nitu, K; Meyer, H H D; Prakash, B S

    2013-08-01

    A highly sensitive enzyme immunoassay (EIA) that used the second antibody coating technique and the cortisol-horseradish peroxidase conjugate as a label for determination of free and total cortisol in blood plasma of dairy animals (cows, buffaloes, and goats) was developed. For biological validation of the EIA, blood samples were collected from the animals at 48 and 24 h before and 0, 12, 24, 36, 48, 60, 72, 84, 96, 108, 120, and 132 h after dexamethasone administration. The EIA was performed directly with 20 μL of fresh plasma (for free cortisol) and also with 20 μL of heat-treated plasma (for total cortisol) after 1:5 dilutions with PBS. Cortisol standards ranging from 0.39 to 200 pg/well/20 μL were used, and the sensitivity of the EIA procedure was found to be 0.39 pg/well/20 μL, which corresponded to 0.02 ng/mL. In comparison with RIA the EIA was at least 4 times more sensitive and required 5 times less cortisol antiserum. In female cattle, buffaloes, and goats, the total, free, and bound plasma cortisol before dexamethasone administration was significantly (P < 0.05) higher than the total, free, and bound cortisol after dexamethasone administration. It can be concluded from these studies that the direct, sensitive EIA validated for estimating the free and total cortisol concentrations was sufficiently reliable and quick for studying the dynamics of cortisol distribution in blood plasma of dairy animals. Copyright © 2013 Elsevier Inc. All rights reserved.

  6. Effects of drugs which influence renal transport systems on the urinary excretion of the beta 2-adrenoceptor agonist clenbuterol and the anabolic steroids ethinylestradiol and methyltestosterone.

    PubMed

    Gleixner, A; Sauerwein, H; Meyer, H H

    1997-01-01

    The aim of this study was to determine whether the illegal application of clenbuterol, ethinylestradiol and methyltestosterone in cattle as growth promoters can be concealed by co-treatment with drugs that affect urinary excretion. Six male veal calves were fed with 0.8 micrograms clenbuterol kg-1 of body weight (BW), 3.5 micrograms ethinylestradiol kg-1 BW and 35 micrograms methyltestosterone kg-1 BW together twice daily for 28 days. At the eighth day of clenbuterol, ethinylestradiol and methyltestosterone treatment each calf was additionally fed either with probenecid, para-aminohippuric acid, trimethoprim, famotidine or cimetidine at three different doses which were increased in weekly intervals. During the treatment 24 h-urine and blood samples (once daily) were obtained and analysed for clenbuterol, ethinylestradiol and methyltestosterone by specific enzyme immunoassay. By high performance liquid chromatography/enzyme immunoassay it was determined whether these drugs or their metabolites interfered with the immunological detection of the growth promoters. Clenbuterol, ethinylestradiol and methyltestosterone could be detected in plasma and urine throughout the whole experiment. Co-treatment with probenecid led to a five-fold reduction in urinary excretion of ethinylestradiol and co-treatment with trimethoprim led to a three-fold reduction in urinary excretion of clenbuterol. None of the drugs reduced urinary excretion of the growth promoters to concentrations below the limit of detection. The detection of these three growth promoters in urine samples from calves which were co-treated with the drugs tested in this study can thus not be prevented.

  7. Diagnostic potential of low molecular weight excretory secretory proteins of Paramphistomum epiclitum for caprine amphistomosis.

    PubMed

    Jaiswal, Amit Kumar; Shanker, Daya; Sudan, Vikrant; Singh, Amit

    2018-06-15

    In the present study, the 75% alcoholic fractionation of excretory-secretory (ES) antigen isolated from 200 to 300 live P. epiclitum was assessed for its diagnostic potential for the detection of caprine amphistomosis by using antibody detection enzyme immunoassay. Prior to enzyme immunoassay, 75% alcoholic fractionation of excretory-secretory (ES) antigen was subjected to SDS- PAGE and western blot analysis for the presence of immunoreactive polypeptides. SDS-PAGE analysis of ES antigen resolved a total 7 polypeptides bands of size 56, 27, 25, 22.5, 12, 11 and 10 kDa. Western blot analysis revealed only two immunoreactive polypeptides (11 kDa and 12 kDa) when polypeptides resolved in SDS-PAGE were probed with known positive pooled serum. None of the polypeptides showed reactions with pooled known negative serum. The working dilutions of antigen, sera and conjugates were determined by checkerboard titration for employing ELISA and cut-off O.D. was calculated 0.616 by using the mean absorbance value of 11 negative kid sera. The sensitivity and specificity of ELISA was found to be 100% and 86.76%, respectively. As per kappa value estimation, the strength of agreement was found to be good. Antibodies to 75% alcoholic fractionation of ES antigen was detected in 20% goats (n = 160) of either sex, although faecal examination detected 10.6% goats to be infected with amphistomosis. The study confirmed that 75% alcoholic fractionation of ES antigen of P. epiclitum based ELISA had good value for serodiagnosis of caprine amphistomosis. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. A rapid magnetic particle-based enzyme immunoassay for human cytomegalovirus glycoprotein B quantification.

    PubMed

    Pires, F; Arcos-Martinez, M Julia; Dias-Cabral, A Cristina; Vidal, Juan C; Castillo, Juan R

    2018-04-17

    Human cytomegalovirus (HCMV) is a herpes virus that can cause severe infections. Still, the available methods for its diagnostic have the main disadvantage of requiring long time to be performed. In this work, a simple magnetic particle-based enzyme immunoassay (mpEIA) for the quantification of glycoprotein B of Human cytomegalovirus (gB-HCMV) in urine samples is proposed. The immunosensor scheme is based on the analyte protein gB-HCMV sandwiched between a primary monoclonal antibody, (MBs-PrG-mAb1), and a secondary anti-gB-HCMV antibody labelled with Horseradish peroxidase (Ab2-HRP) to allow spectrophotometric detection. The mpEIA analytical performance was tested in urine samples, showing a linear dependence between gB-HCMV concentration and the absorbance signal at 450 nm in a range of concentrations from 90 to 700 pg mL -1 . The calculated detection limits for gB-HCMV were 90 ± 2 pg mL -1 and the RSD was about 6.7% in urine samples. The immunosensor showed good selectivity against other viruses from Herpesviridae family, namely varicella zoster and Epstein Barr viruses. The recoveries of spiked human urine samples at 0.30-0.50 ng mL -1 concentration levels of gB-HCMV ranged between 91 to 105%. The proposed mpEIA method was validated following the guidelines of the European Medicines Agency (EMEA-2014), and allows rapid, successful and easy quantification of gB-HCMV in urine samples. Copyright © 2018 Elsevier B.V. All rights reserved.

  9. Comparison of 2 enzyme immunoassays and a radioimmunoassay for measurement of progesterone concentrations in bovine plasma, skim milk, and whole milk.

    PubMed

    Colazo, Marcos G; Ambrose, Divakar J; Kastelic, John P; Small, Julie A

    2008-01-01

    The objective of this study was to compare 2 enzyme immunoassays (EIAs) with a radioimmunoassay (RIA) as to sensitivity and accuracy in the measurement of the progesterone (P4) concentration in bovine plasma, skim milk, and whole milk. The 72 samples from 24 lactating dairy cows expected to have either a high P4 concentration (cows in diestrus or pregnant) or a low P4 concentration (cows in estrus or anestrus) were analyzed by RIA, solid-phase EIA (SPEIA), which included a solvent extraction step, or direct EIA (DEIA) without solvent extraction. The overall mean concentrations of P4 did not differ (P < 0.4) among the assays. However, for the cows that were in diestrus or pregnant, the mean P4 concentrations (and standard error) were higher (P < 0.03), regardless of sample type, with RIA than with SPEIA, at 7.3 (0.7) and 6.1 (0.6) ng/mL, respectively. When only the high-P4 samples analyzed by RIA were compared, the mean P4 concentration was higher (P < 0.001) in whole milk than in skim milk, at 9.8 (1.0) and 4.1 (0.7) ng/mL, respectively. Although the mean P4 concentrations in the low-P4 samples did not differ (P < 0.80) among assays, the proportions of cows with a P4 concentration > or = 1 ng/mL were 3%, 14%, and 44% for RIA, SPEIA, and DEIA, respectively (P < 0.01; DEIA > SPEIA > RIA).

  10. Evaluation of Correlation between Pretest Probability for Clostridium difficile Infection and Clostridium difficile Enzyme Immunoassay Results

    PubMed Central

    Reske, Kimberly A.; Hink, Tiffany; Dubberke, Erik R.

    2016-01-01

    ABSTRACT The objective of this study was to evaluate the clinical characteristics and outcomes of hospitalized patients tested for Clostridium difficile and determine the correlation between pretest probability for C. difficile infection (CDI) and assay results. Patients with testing ordered for C. difficile were enrolled and assigned a high, medium, or low pretest probability of CDI based on clinical evaluation, laboratory, and imaging results. Stool was tested for C. difficile by toxin enzyme immunoassay (EIA) and toxigenic culture (TC). Chi-square analyses and the log rank test were utilized. Among the 111 patients enrolled, stool samples from nine were TC positive and four were EIA positive. Sixty-one (55%) patients had clinically significant diarrhea, 19 (17%) patients did not, and clinically significant diarrhea could not be determined for 31 (28%) patients. Seventy-two (65%) patients were assessed as having a low pretest probability of having CDI, 34 (31%) as having a medium probability, and 5 (5%) as having a high probability. None of the patients with low pretest probabilities had a positive EIA, but four were TC positive. None of the seven patients with a positive TC but a negative index EIA developed CDI within 30 days after the index test or died within 90 days after the index toxin EIA date. Pretest probability for CDI should be considered prior to ordering C. difficile testing and must be taken into account when interpreting test results. CDI is a clinical diagnosis supported by laboratory data, and the detection of toxigenic C. difficile in stool does not necessarily confirm the diagnosis of CDI. PMID:27927930

  11. Enzyme-linked immunosorbent assay for determination of aflatoxin M1 based on magnetic nanoparticles

    NASA Astrophysics Data System (ADS)

    Atanasova, M. K.; Ivanova, N. V.; Godjevargova, T. I.

    2017-02-01

    A sensitive enzyme immunoassay with magnetic nanoparticles (Method A) for the quantitative determination of aflatoxin M1 in milk was developed. This immunoassay was based on the immobilization of monoclonal antibody (mAb) on the modified magnetic nanoparticles (MNPs-NH2). It was observed that for each mg of the MNPs, 25 µg of antibody was immobilized. Both aflatoxin M1 in the sample and aflatoxin M1-BSA-peroxidase conjugate competed for the immobilized antibody. The proposed Method A was compared with other method (B). The Method B was based on the immobilization of aflatoxin M1-BSA conjugate on the MNPs-NH2, which competed with the aflatoxin M1 in the sample for binding to the added mAb. The binding of mAb to the aflatoxin M1-BSA-MNPs-NH2 was detected using a target secondary IgG-peroxidase antibody. The analytical characteristics of the two methods were compared. Real milk samples were investigated for present of aflatoxin M1. Two methods were based on the use of MNPs as a solid support for covalently immunoreagents immobilization. A comfortable separation of bound and free fraction of the tracer can be performed only through a simple collection of the MNPs by a permanent magnet. The application of MNPs helps to eliminate non-specific binding and to retain higher activity of bound biomolecules. The development of a MNPs-based ELISA for determination of aflatoxin M1 has a great potential to supersede the traditional ELISA for aflatoxin M1 diagnosis.

  12. Plasma atrial natriuretic peptide and N-terminal pro B-type natriuretic peptide concentrations in dogs with right-sided congestive heart failure

    PubMed Central

    KANNO, Nobuyuki; HORI, Yasutomo; HIDAKA, Yuichi; CHIKAZAWA, Seishiro; KANAI, Kazutaka; HOSHI, Fumio; ITOH, Naoyuki

    2015-01-01

    The clinical utility of plasma natriuretic peptide concentrations in dogs with right-sided congestive heart failure (CHF) remains unclear. We investigated whether plasma levels of atrial natriuretic peptide (ANP) and N-terminal pro B-type natriuretic peptide (NT-proBNP) are useful for assessing the congestive signs of right-sided heart failure in dogs. This retrospective study enrolled 16 healthy dogs and 51 untreated dogs with presence (n=28) or absence (n=23) of right-sided CHF. Medical records of physical examinations, thoracic radiography and echocardiography were reviewed. The plasma concentration of canine ANP was measured with a chemiluminescent enzyme immunoassay. Plasma NT-proBNP concentrations were determined using an enzyme immunoassay. Plasma ANP and NT-proBNP concentrations in dogs with right-sided CHF were significantly higher than in healthy controls and those without right-sided CHF. The plasma NT-proBNP concentration >3,003 pmol/l used to identify right-sided CHF had a sensitivity of 88.5% and specificity of 90.3%. An area under the ROC curve (AUC) was 0.93. The AUC for NT-proBNP was significantly higher than the AUCs for the cardiothoracic ratio, vertebral heart score, ratio of right ventricular end-diastolic internal diameter to body surface area, tricuspid late diastolic flow and ratio of the velocities of tricuspid early to late diastolic flow. These results suggest that plasma ANP and NT-proBNP concentrations increase markedly in dogs with right-sided CHF. Particularly, NT-proBNP is simple and helpful biomarkers to assess the right-sided CHF. PMID:26607133

  13. Human chorionic gonadotropin detection in cerebrospinal fluid of patients with a germinoma and its prognostic significance: assessment by using a highly sensitive enzyme immunoassay.

    PubMed

    Fukuoka, Kohei; Yanagisawa, Takaaki; Suzuki, Tomonari; Shirahata, Mitsuaki; Adachi, Jun-Ichi; Mishima, Kazuhiko; Fujimaki, Takamitsu; Katakami, Hideki; Matsutani, Masao; Nishikawa, Ryo

    2016-11-01

    OBJECTIVE Human chorionic gonadotropin (HCG) can be detected in a certain population of patients with a germinoma, but the frequency of germinoma HCG secretion and the prognostic value of HCG in the CSF are unknown. METHODS The authors measured HCG levels in sera and CSF in patients with a histologically confirmed germinoma by using a highly sensitive assay known as an immune complex transfer enzyme immunoassay (EIA), which is more than 100 times as sensitive as the conventional method, and they analyzed the correlation between HCG levels and the prognoses of patients with a germinoma. RESULTS HCG levels in sera and CSF of 35 patients with a germinoma were examined with the immune complex transfer EIA. The median CSF HCG levels in patients with a germinoma during the pretreatment and posttreatment evaluations were 192.5 pg/ml (range 1.2-13,116.5 pg/ml) and 18.7 pg/ml (1.2-283.9 pg/ml), respectively. Before treatment, the CSF HCG level was greater than the cutoff value in 85.7% of the patients with a germinoma. The authors compared survival rates among the patients by using a CSF HCG cutoff level of 1000 pg/ml, and the difference was statistically significant between the groups (p = 0.029, log-rank test). CONCLUSIONS Results of this study demonstrate that most germinomas secrete HCG. Patients with a germinoma that secretes higher amounts of HCG in their CSF experienced recurrence more frequently than those with lower CSF HCG levels.

  14. Extracellular enzyme production and cheating in Pseudomonas fluorescens depend on diffusion rates

    PubMed Central

    Allison, Steven D.; Lu, Lucy; Kent, Alyssa G.; Martiny, Adam C.

    2014-01-01

    Bacteria produce extracellular enzymes to obtain resources from complex chemical substrates, but this strategy is vulnerable to cheating by cells that take up reaction products without paying the cost of enzyme production. We hypothesized that cheating would suppress enzyme production in co-cultures of cheater and producer bacteria, particularly under well-mixed conditions. To test this hypothesis, we monitored protease expression and frequencies of Pseudomonas fluorescens producer and cheater genotypes over time in mixed liquid cultures and on agar plates. In mixed culture inoculated with equal frequencies of cheaters and producers, enzyme concentration declined to zero after 20 days, consistent with our hypothesis. We observed a similar decline in cultures inoculated with producers only, suggesting that cheater mutants arose de novo and swept the population. DNA sequencing showed that genetic changes most likely occurred outside the protease operon. In one experimental replicate, the population regained the ability to produce protease, likely due to further genetic changes or population dynamics. Under spatially structured conditions on agar plates, cheaters did not sweep the population. Instead, we observed a significant increase in the variation of enzyme activity levels expressed by clones isolated from the population. Together these results suggest that restricted diffusion favors a diversity of enzyme production strategies. In contrast, well-mixed conditions favor population sweeps by cheater strains, consistent with theoretical predictions. Cheater and producer strategies likely coexist in natural environments with the frequency of cheating increasing with diffusion rate. PMID:24782855

  15. Markov-state model for CO2 binding with carbonic anhydrase under confinement

    NASA Astrophysics Data System (ADS)

    Chen, Gong; Xu, Weina; Lu, Diannan; Wu, Jianzhong; Liu, Zheng

    2018-01-01

    Enzyme immobilization with a nanostructure material can enhance its stability and facilitate reusability. However, the apparent activity is often compromised due to additional diffusion barriers and complex interactions with the substrates and solvent molecules. The present study elucidates the effects of the surface hydrophobicity of nano-confinement on CO2 diffusion to the active site of human carbonic anhydrase II (CA), an enzyme that is able to catalyze CO2 hydration at extremely high turnover rates. Using the Markov-state model in combination with coarse-grained molecular dynamics simulations, we demonstrate that a hydrophobic cage increases CO2 local density but hinders its diffusion towards the active site of CA under confinement. By contrast, a hydrophilic cage hinders CO2 adsorption but promotes its binding with CA. An optimal surface hydrophobicity can be identified to maximize both the CO2 occupation probability and the diffusion rate. The simulation results offer insight into understanding enzyme performance under nano-confinement and help us to advance broader applications of CA for CO2 absorption and recovery.

  16. Cyanide does more to inhibit heme enzymes, than merely serving as an active-site ligand

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Parashar, Abhinav; Venkatachalam, Avanthika; Gideon, Daniel Andrew

    Highlights: • Cyanide (CN) is a well-studied toxic principle, known to inhibit heme-enzymes. • Inhibition is supposed to result from CN binding at the active site as a ligand. • Diverse heme enzymes’ CN inhibition profiles challenge prevailing mechanism. • Poor binding efficiency of CN at low enzyme concentrations and ligand pressures. • CN-based diffusible radicals cause ‘non-productive electron transfers’ (inhibition). - Abstract: The toxicity of cyanide is hitherto attributed to its ability to bind to heme proteins’ active site and thereby inhibit their activity. It is shown herein that the long-held interpretation is inadequate to explain several observations inmore » heme-enzyme reaction systems. Generation of cyanide-based diffusible radicals in heme-enzyme reaction milieu could shunt electron transfers (by non-active site processes), and thus be detrimental to the efficiency of oxidative outcomes.« less

  17. Characterization of Antibodies for Grain-Specific Gluten Detection.

    PubMed

    Sharma, Girdhari M; Rallabhandi, Prasad; Williams, Kristina M; Pahlavan, Autusa

    2016-03-01

    Gluten ingestion causes immunoglobulin E (IgE)-mediated allergy or celiac disease in sensitive individuals, and a strict gluten-free diet greatly limits food choices. Immunoassays such as enzyme-linked immunosorbent assay (ELISA) are used to quantify gluten to ensure labeling compliance of gluten-free foods. Anti-gluten antibodies may not exhibit equal affinity to gluten from wheat, rye, and barley. Moreover, because wheat gluten is commonly used as a calibrator in ELISA, accurate gluten quantitation from rye and barley contaminated foods may be compromised. Immunoassays utilizing grain-specific antibodies and calibrators may help improve gluten quantitation. In this study, polyclonal antibodies raised against gluten-containing grain-specific peptides were characterized for their immunoreactivity to gluten from different grain sources. Strong immunoreactivity to multiple gluten polypeptides from wheat, rye, and barley was observed in the range 34 to 43 kDa with anti-gliadin, 11 to 15 and 72 to 95 kDa with anti-secalin, and 30 to 43 kDa with anti-hordein peptide antibodies, respectively. Minimal or no cross-reactivity with gluten from other grains was observed among these antibodies. The anti-consensus peptide antibody raised against a repetitive amino acid sequence of proline and glutamine exhibited immunoreactivity to gluten from wheat, rye, barley, and oat. The antibodies exhibited similar immunoreactivity with most of the corresponding grain cultivars by ELISA. The high specificity and minimal cross-reactivity of grain-specific antibodies suggest their potential use in immunoassays for accurate gluten quantitation. © Published 2016. This article is a U.S. Government work and is in the public domain in the USA.

  18. Good performance of an immunoassay based method for nevirapine measurements in human breast milk.

    PubMed

    Salado-Rasmussen, Kirsten; Theilgaard, Zahra Persson; Chiduo, Mercy; Pedersen, Court; Gerstoft, Jan; Katzenstein, Terese Lea

    2011-07-01

    Understanding the distribution of antiretro-virals in breastfeeding HIV-positive mothers is essential, both for prevention of mother-to-child HIV transmission and for research on the development of drug resistance. The ARK nevirapine (NVP)-test is an immunoassay method for nevirapine measurements, developed and validated for plasma use. In this study, the ARK NVP-test was evaluated for measurement of nevirapine concentrations in breast milk. High performance liquid chromatography (HPLC) is the method currently used to determine nevirapine in breast milk. This method, however, requires complicated extraction techniques. The ARK method employs an immunoassay technology and requires a small sample volume (40 μL) and no pre-treatment of the samples. Commercial enzyme and antibody were used and calibration standards and quality controls were prepared from pooled breast milk from HIV-uninfected women. Clinical samples from HIV-infected women receiving a single-dose of nevirapine were analyzed. Precision and accuracy were evaluated with two concentrations of quality control materials analyzed in three replicates on four different days and was <4%, and between 96.5% and 104.6%, respectively. Clinical samples were analyzed and CVs ranged from 0.0% to 11.1%. The median nevirapine concentration in breast milk 1 week post-partum was 0.29 μg/mL (range 0.11-0.90 μg/mL) in women treated with a single-dose of nevirapine. The ease of use and small sample volume makes the ARK assay an attractive alternative to HPLC analyses for determinations of nevirapine concentrations in breast milk.

  19. Development of an ultra-high sensitive immunoassay with plasma biomarker for differentiating Parkinson disease dementia from Parkinson disease using antibody functionalized magnetic nanoparticles.

    PubMed

    Yang, Shieh-Yueh; Chiu, Ming-Jang; Lin, Chin-Hsien; Horng, Herng-Er; Yang, Che-Chuan; Chieh, Jen-Jie; Chen, Hsin-Hsien; Liu, Bing-Hsien

    2016-06-08

    It is difficult to discriminate healthy subjects and patients with Parkinson disease (PD) or Parkinson disease dementia (PDD) by assaying plasma α-synuclein because the concentrations of circulating α-synuclein in the blood are almost the same as the low-detection limit using current immunoassays, such as enzyme-linked immunosorbent assay. In this work, an ultra-sensitive immunoassay utilizing immunomagnetic reduction (IMR) is developed. The reagent for IMR consists of magnetic nanoparticles functionalized with antibodies against α-synuclein and dispersed in pH-7.2 phosphate-buffered saline. A high-Tc superconducting-quantum-interference-device (SQUID) alternative-current magnetosusceptometer is used to measure the IMR signal of the reagent due to the association between magnetic nanoparticles and α-synuclein molecules. According to the experimental α-synuclein concentration dependent IMR signal, the low-detection limit is 0.3 fg/ml and the dynamic range is 310 pg/ml. The preliminary results show the plasma α-synuclein for PD patients distributes from 6 to 30 fg/ml. For PDD patients, the concentration of plasma α-synuclein varies from 0.1 to 100 pg/ml. Whereas the concentration of plasma α-synuclein for healthy subjects is significantly lower than that of PD patients. The ultra-sensitive IMR by utilizing antibody-functionalized magnetic nanoparticles and high-Tc SQUID magnetometer is promising as a method to assay plasma α-synuclein, which is a potential biomarker for discriminating patients with PD or PDD.

  20. Reproducibility of positive results for the detection of serum galactomannan by Platelia™ aspergillus EIA.

    PubMed

    Pedroza, Kelly C M C; de Matos, Sócrates B; de Moura, Daniel L; Oliveira, Mônica B B; Araújo, Marco A S; Nascimento, Roberto J M; Lima, Fernanda W M

    2013-10-01

    Galactomannan (GM) was recently included in consensus guidelines as an indirect mycological criterion for the diagnosis of invasive aspergillosis. Currently, there is an enzyme immunoassay available to detect GM in biological samples, the Platelia™ Aspergillus EIA. In this study, the reproducibility of positive results obtained using this assay was evaluated using serum samples from neutropenic patients. A trend toward lower values was observed, and 55 %(27/49) of positive results were negative after retesting. A low reproducibility of positive results for the detection of GM in serum was observed.

  1. Designer phenethylamines routinely found in human urine: 2-ethylamino-1-phenylbutane and 2-amino-1-phenylbutane.

    PubMed

    Uralets, Victor; App, Mike; Rana, Sumandeep; Morgan, Stewart; Ross, Wayne

    2014-03-01

    2-Ethylamino-1-phenylbutane (EAPB) and 2-amino-1-phenylbutane (APB) were identified by gas chromatography-mass spectrometry in multiple urine samples submitted for stimulant drug testing and screened positive for amphetamines by enzyme immunoassay. Forty-two samples from all over the USA were found, containing both analytes during a 3-month period May-July 2013. A sports dietary supplement 'CRAZE' has been determined to be one of the sources of EAPB supply. EAPB along with its suggested metabolite APB were detected in a urine sample, obtained from a person known to use 'CRAZE'.

  2. [Development of an optimal scheme for calculating results of the use of an immunoenzyme test-system for determining the antigenic activity of a cultured antirabies vaccine].

    PubMed

    Tsetlin, E M; Volkova, R A

    1996-01-01

    Ninety-eight lots of commercial antirabies vaccine manufactured by Immunopreparat Research and Production Amalgamation have been tested using enzyme immunoassay system for the detection of rabies virus antigens. Comparison of different variants of interpreting and expressing the results helped define the optimal method for assessment of vaccine titer and reference values: optical density value equal to 0.2 is taken as the cut-off. Antigenic activity of the vaccine may be expressed in international units, similarly as immunogenic activity.

  3. Distinction of Fly Artifacts from Human Blood using Immunodetection.

    PubMed

    Rivers, David B; Acca, Gillian; Fink, Marc; Brogan, Rebecca; Chen, Dorothy; Schoeffield, Andrew

    2018-02-21

    Insect stains produced by necrophagous flies are indistinguishable morphologically from human bloodstains. At present, no diagnostic tests exist to overcome this deficiency. As the first step toward developing a chemical test to recognize fly artifacts, polyclonal antisera were generated in rats against three distinct antigenic sequences of fly cathepsin D-like proteinase, an enzyme that is structurally distinct in cyclorrhaphous Diptera from other animals. The resulting rat antisera bound to artifacts produced by Protophormia terraenovae and synthetic peptides used to generate the polyclonal antisera, but not with any type of mammalian blood tested in immunoassays. Among the three antisera, anti-md3 serum displayed the highest reactivity for fly stains, demonstrated cross-reactivity for all synthetic peptides representing antigenic sequences of the mature fly enzyme, and bound artifacts originating from the fly digestive tract. Further work is needed to determine whether the antisera are suitable for non-laboratory conditions. © 2018 American Academy of Forensic Sciences.

  4. Clearing of suspensions of Micrococcus lysodeikticus catalysed by lysozymes from hen, goose, and turkey egg whites, human milk, and phage T4. Assessment of potential as signal generators for homogeneous enzyme immunoassays for urinary steroids.

    PubMed

    Cooke, Delwyn G; Blackwell, Leonard F

    2007-01-01

    Lysozymes (3.2.1.17) from goose (Anser anser) egg white, turkey (Melagris gallopavo) egg white, phage T4 and human milk were compared with hen egg white lysozyme in their ability to clear a suspension of Micrococcus lysodeikticus. All of the lysozymes, except hen egg white lysozyme, catalysed the clearing of the Micrococcus lysodeikticus suspension in a biphasic fashion. Compared to hen egg white lysozyme, the total absorbance or transmission change over 5 and 20 minutes was less in all cases, except for human lysozyme. Human lysozyme was, therefore, a potential alternative, more rapid signal generator for the measurement of urinary estrone glucuronide excretion rates because of its structural similarity to hen egg white lysozyme. The apparent K(M) values for hen egg white lysozyme increased with the enzyme concentration.

  5. Spatial and temporal control of microwave triggered chemiluminescence: a protein detection platform.

    PubMed

    Previte, Michael J R; Aslan, Kadir; Geddes, Chris D

    2007-09-15

    We have combined the principles of microwave circuitry and antenna design and our recent work in microwave-triggered metal-enhanced chemiluminescence to now "trigger" chemically and enzyme-catalyzed chemiluminescent reactions with spatial and temporal control. With this technology platform, we achieve spatial and temporal control of enzyme and chemically catalyzed chemiluminescence reactions to achieve more than 500-fold increases in "on-demand" photon flux from chemically catalyzed chemiluminescent reactions. We also report a 6-fold increase in photon flux from HRP-catalyzed assays on disposable coverslips functionalized with HRP and placed proximal to the substrates modified with thin-film aluminum triangle disjointed "bow-tie" structures. In addition, we demonstrate the applicability of this technology to develop multiplexed or high-throughput chemiluminescent assays. We also demonstrate the clinical and biological relevance of this technology platform by affixing aluminum structures in proximity to HRP protein immobilized on nitrocellulose to improve the sensitivity for this model Western blot scheme by 50-fold. We believe analytical applications that rely on enzyme-catalyzed chemiluminescence, such as immunoassays, may greatly benefit from this new platform technology.

  6. Characterization of a monoclonal antibody against neopterin using an enzyme-linked immunosorbent assay with penicillinase as label.

    PubMed

    Malakaneh, M; Rasaee, M J; Rahbarizadeh, F; Madani, R; Forozandeh, M M; Khabiri, K; Alimohammadian, M H

    2001-04-01

    An active ester derivative of neopterin was prepared using 4-(N-maleimidomethyl) cyclohexan 4-carboxilic acid N-hydroxy succinimide ester (MCH-NHS), conjugated to bovine serum albumin (BSA) and injected for antibody production (for both monoclonal and polyclonal antibodies). High titer antibody producing spleen cells were removed and fused with myeloma cells of Sp2/0 origin. Neopterin was conjugated to the enzyme penicillinase by a one-step glutaraldehyde method, which was used as tracer. A novel enzyme immunoassay was developed using this conjugate to screen and characterize the monoclonal antibody (MAb) produced in these experiments. After limiting dilutions, it was found that antibody produced by one clone with a Ka value of 7.6 x 10-7 mol/L was specific for a number of structurally related molecules. This clone was found to be of IgG class and IgG2a subclass. The standard curvewas constructed with a sensitivity of 10 pg/well (100 pg/mL) covering up to 1 ng/mL.

  7. Isolation and functional effects of monoclonal antibodies binding to thymidylate synthase.

    PubMed

    Jastreboff, M M; Todd, M B; Malech, H L; Bertino, J R

    1985-01-29

    Monoclonal antibodies against electrophoretically pure thymidylate synthase from HeLa cells have been produced. Antibodies (M-TS-4 and M-TS-9) from hybridoma clones were shown by enzyme-linked immunoassay to recognize thymidylate synthase from a variety of human cell lines, but they did not bind to thymidylate synthase from mouse cell lines. The strongest binding of antibodies was observed to enzyme from HeLa cells. These two monoclonal antibodies bind simultaneously to different antigenic sites on thymidylate synthase purified from HeLa cells, as reflected by a high additivity index and results of cross-linked radioimmunoassay. Both monoclonal antibodies inhibit the activity of thymidylate synthase from human cell lines. The strongest inhibition was observed with thymidylate synthase from HeLa cells. Monoclonal antibody M-TS-9 (IgM subclass) decreased the rate of binding of [3H]FdUMP to thymidylate synthase in the presence of 5,10-methylenetetrahydrofolate while M-TS-4 (IgG1) did not change the rate of ternary complex formation. These data indicate that the antibodies recognize different epitopes on the enzyme molecule.

  8. Rapid, automated, parallel quantitative immunoassays using highly integrated microfluidics and AlphaLISA

    PubMed Central

    Tak For Yu, Zeta; Guan, Huijiao; Ki Cheung, Mei; McHugh, Walker M.; Cornell, Timothy T.; Shanley, Thomas P.; Kurabayashi, Katsuo; Fu, Jianping

    2015-01-01

    Immunoassays represent one of the most popular analytical methods for detection and quantification of biomolecules. However, conventional immunoassays such as ELISA and flow cytometry, even though providing high sensitivity and specificity and multiplexing capability, can be labor-intensive and prone to human error, making them unsuitable for standardized clinical diagnoses. Using a commercialized no-wash, homogeneous immunoassay technology (‘AlphaLISA’) in conjunction with integrated microfluidics, herein we developed a microfluidic immunoassay chip capable of rapid, automated, parallel immunoassays of microliter quantities of samples. Operation of the microfluidic immunoassay chip entailed rapid mixing and conjugation of AlphaLISA components with target analytes before quantitative imaging for analyte detections in up to eight samples simultaneously. Aspects such as fluid handling and operation, surface passivation, imaging uniformity, and detection sensitivity of the microfluidic immunoassay chip using AlphaLISA were investigated. The microfluidic immunoassay chip could detect one target analyte simultaneously for up to eight samples in 45 min with a limit of detection down to 10 pg mL−1. The microfluidic immunoassay chip was further utilized for functional immunophenotyping to examine cytokine secretion from human immune cells stimulated ex vivo. Together, the microfluidic immunoassay chip provides a promising high-throughput, high-content platform for rapid, automated, parallel quantitative immunosensing applications. PMID:26074253

  9. Exogenous superoxide dismutase may lose its antidotal ability on rice leaves

    USDA-ARS?s Scientific Manuscript database

    Leaf diffusates of the resistant rice cultivars suppressed spore germination of blast fungus (Magnaporthe grisea). Bovine Cu-Zn superoxide dismutase (SOD) added to the diffusate abolished its toxicity. However, the enzyme added to the inoculum did not affect the toxicity of the diffusate. Even the s...

  10. Towards improved artificial lungs through biocatalysis.

    PubMed

    Kaar, Joel L; Oh, Heung-Il; Russell, Alan J; Federspiel, William J

    2007-07-01

    Inefficient CO(2) removal due to limited diffusion represents a significant barrier in the development of artificial lungs and respiratory assist devices, which use hollow fiber membranes (HFMs) as the blood-gas interface and can require large blood-contacting membrane area. To offset the underlying diffusional challenge, "bioactive" HFMs that facilitate CO(2) diffusion were prepared via covalent immobilization of carbonic anhydrase (CA), an enzyme which catalyzes the conversion of bicarbonate in blood to CO(2), onto the surface of plasma-modified conventional HFMs. This study examines the impact of enzyme attachment on the diffusional properties and the rate of CO(2) removal of the bioactive membranes. Plasma deposition of surface reactive hydroxyls, to which CA could be attached, did not change gas permeance of the HFMs or generate membrane defects, as determined by scanning electron microscopy, when low plasma discharge power and short exposure times were employed. Cyanogen bromide activation of the surface hydroxyls and subsequent modification with CA resulted in near monolayer enzyme coverage (88%) on the membrane. The effect of increased plasma discharge power and exposure time on enzyme loading was negligible while gas permeance studies showed enzyme attachment did not impede CO(2) or O(2) diffusion. Furthermore, when employed in a model respiratory assist device, the bioactive membranes improved CO(2) removal rates by as much as 75% from physiological bicarbonate solutions with no enzyme leaching. These results demonstrate the potential of bioactive HFMs with immobilized CA to enhance CO(2) exchange in respiratory devices.

  11. False-positive ethyl glucuronide immunoassay screening caused by a propyl alcohol-based hand sanitizer.

    PubMed

    Arndt, Torsten; Grüner, Joachim; Schröfel, Stefanie; Stemmerich, Karsten

    2012-11-30

    Urine ethyl glucuronide (EtG) is considered as a specific marker of recent ethanol consumption. We describe false-positive DRI(®) EIA EtG enzyme immunoassay results caused by propyl glucuronides in urine after using a propanol-based hand sanitizer. EtG screening was done with the DRI(®) EIA EtG assay (Microgenics), using a cut-off of 0.5 mg/L as recommended by the manufacturer and of 0.1 mg/L as demanded by the German Regulations for Reissuing Drivers Licenses. Confirmatory EtG analysis was done with the ClinMass(®) EtG LC-MS/MS testkit (Recipe), extended by the mass transitions 235.1→75.1, 235.1→85.1, and 235.1→113.1 for the detection of the 1- and 2-propyl glucuronides. Self-experiments were done by staff members of our lab (n=7), using 3 mL Sterillium(®) Classic Pure (30 g/100 g 1-propanol and 45 g/100 g 2-propanol) for hand sanitation every quarter of an hour for 8 h according to DIN EN 1500:2011-05 with and without an exhauster and by passive inhalation of the sanitizer vapor. Spot urine samples were taken immediately before and up to 24 h after the first sanitizer use. False-positive immunoassay results of up to 4 mg/L or 2.3 mg/g creatinine were obtained after normal use of the sanitizer and also after passive inhalation of the sanitizer vapor (up to 0.89 mg/L or 0.61 mg/g). Immunoassay results were positive even after 4-fold use of the sanitizer (up to 0.14 mg/L or 0.38 mg/g) and up to 6 h after the last sanitizer contact (maximum 0.63 mg/L and 0.33 mg/g for sanitizer users and 0.25 mg/g after passive inhalation). Spiking of EtG-free urine with 1-propyl glucuronide (Athena Environmental Sciences) between 0.05 and 10 mg/L clearly demonstrated a cross reaction of the immunoassay of approx. 10% as compared to EtG. LC-MS/MS of urines with a positive immunoassay EtG result did not show EtG signals, but distinct signals of 1-propyl glucuronide (n-propyl glucuronide) and 2-propyl glucuronide (iso-propyl glucuronide). An exhauster effectively prevented the inhalation of the sanitizer vapor, the formation of propyl glucuronides and thus false-positive DRI(®) EIA EtG screening results, proving that propyl alcohols are almost exclusively taken up by respiration. The widespread use of propanol-containing products such as hand sanitizers may lead to sufficient uptake of propyl alcohols and excretion of significant amounts of propyl glucuronides to yield false-positive DRI(®) EIA EtG screening results. Thus, positive EtG immunoassay results have to be controlled by mass-spectrometry, in clinical cases at least if ethanol intake is denied by the patient. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  12. Comparison of a novel chemiluminescence enzyme immunoassay (CLEIA) with enzyme-linked immunosorbent assay (ELISA) for the determination of MPO-ANCA in patients with ANCA-associated vasculitis.

    PubMed

    Hirose, Orie; Itabashi, Mitsuyo; Takei, Takashi; Nitta, Kosaku

    2015-03-01

    Myeloperoxidase (MPO) anti-neutrophil cytoplasmic antibody (ANCA) represents the serological hallmark of ANCA-associated vasculitis (AAV). We evaluated the analytical and diagnostic accuracy of chemiluminescence enzyme immunoassay (CLEIA) versus enzyme-linked immunosorbent assay (ELISA) for the detection of MPO-ANCA. A total of 242 sera obtained from 51 patients with AAV and 103 patients without AAV were tested for MPO-ANCA by ELISA (NephroScholor MPOANC II) and CLEIA (the STACIA MEBLux test). Disease activity in the patients with AAV was determined based on the Birmingham Vasculitis Activity Score. We analyzed the correlations between the MPO-ANCA titers determined by the CLEIA and those determined by the ELISA, and also between the MPO-ANCA titers and the disease activity. The MPO-ANCA titers determined by the CLEIA (x) were strongly correlated with those determined by the ELISA (y). The correlation could be expressed by the following equation in this study: y = 1.8x + 7.7 (r = 0.96; p < 0.0001). At the cutoff value of 3.5 U/ml, the CLEIA yielded positive test results for MPO-ANCA in 73 of the 242 sera (30.2%), while at the cutoff value of 20 U/ml, ELISA yielded positive test results in 57 of the 242 sera (23.6%). The CLEIA yielded false-positive test results in 4 of the 120 sera obtained from the non-AAV patients (3.3%), whereas the ELISA yielded a false-positive result in only 1 of the 120 sera obtained from the non-AAV patients (0.8%). The sensitivity and specificity of the CLEIA for the diagnosis of AAV were 100% and 96.7%, respectively, while those of the ELISA were 94.3% and 99.2%, respectively. The sensitivity and specificity of the CLEIA for the prediction of active disease were 100% and 64.4%, respectively, while those of the ELISA were 94.3% and 73.6%, respectively. The false positivity rate of the CLEIA for MPO-ANCA tended to be high as compared with that of the ELISA. Also, according to the correlation coefficient between the results of the CLEIA and the ELISA calculated in this study, it is necessary to pay attention to the differences in the sensitivity and specificity between CLEIA and ELISA.

  13. Effect of low frequency, low amplitude magnetic fields on the permeability of cationic liposomes entrapping carbonic anhydrase: I. Evidence for charged lipid involvement.

    PubMed

    Ramundo-Orlando, A; Morbiducci, U; Mossa, G; D'Inzeo, G

    2000-10-01

    The influence of low frequency (4-16 Hz), low amplitude (25-75 mu T) magnetic fields on the diffusion processes in enzyme-loaded unilamellar liposomes as bioreactors was studied. Cationic liposomes containing dipalmitoylphosphatidylcholine, cholesterol, and charged lipid stearylamine (SA) at different molar ratios (6:3:1 or 5:3:2) were used. Previous kinetic experiments showed a very low self-diffusion rate of the substrate p-nitrophenyl acetate (p-NPA) across intact liposome bilayer. After 60 min of exposure to 7 Hz sinusoidal (50 mu T peak) and parallel static (50 mu T) magnetic fields the enzyme activity, as a function of increased diffusion rate of p-NPA, rose from 17 +/- 3% to 80 +/- 9% (P < .0005, n = 15) in the 5:3:2 liposomes. This effect was dependent on the SA concentration in the liposomes. Only the presence of combined sinusoidal (AC) and static (DC) magnetic fields affected the p-NPA diffusion rates. No enzyme leakage was observed. Such studies suggest a plausible link between the action of extremely low frequency magnetic field on charged lipids and a change of membrane permeability. Copyright 2000 Wiley-Liss, Inc.

  14. Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays

    PubMed Central

    Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D

    2002-01-01

    Aims: To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). Methods: The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques—an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. Results: All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (κ > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (κ = 0.63). Conclusion: The assay kit marketed as Varelisa allows accurate detection of LKM1. PMID:12461054

  15. Detection of liver kidney microsomal type 1 antibody using molecularly based immunoassays.

    PubMed

    Kerkar, N; Ma, Y; Davies, E T; Cheeseman, P; Mieli-Vergani, G; Vergani, D

    2002-12-01

    To assess the diagnostic value of two commercial molecularly based immunoassays detecting liver kidney microsomal type 1 antibody (LKM1). The performance of Varelisa and LKM1 enzyme linked immunosorbent assay (ELISA) was compared with immunofluorescence, and two validated research techniques-an in house ELISA and a radioligand assay measuring antibodies to P4502D6. Thirty serum samples from three patients with autoimmune hepatitis type 2 covering immunofluorescence titres of 1/10 to 1/10 240 and 55 LKM1 negative controls were tested. All 30 sera that were LKM1 positive by immunofluorescence were positive by the in house ELISA, the radioligand assay, and LKM1-ELISA, and 29 were also positive by Varelisa. None of the 55 sera negative for LKM1 by immunofluorescence was positive by the in house ELISA and radioligand assay, but one was positive by Varelisa and 14 were positive using the LKM1-ELISA. Agreement between immunofluorescence, the in house ELISA, the radioligand assay, and Varelisa was high (kappa > 0.8), and agreement between immunofluorescence and LKM1-ELISA was moderate (kappa = 0.63). The assay kit marketed as Varelisa allows accurate detection of LKM1.

  16. A short history, principles, and types of ELISA, and our laboratory experience with peptide/protein analyses using ELISA.

    PubMed

    Aydin, Suleyman

    2015-10-01

    Playing a critical role in the metabolic homeostasis of living systems, the circulating concentrations of peptides/proteins are influenced by a variety of patho-physiological events. These peptide/protein concentrations in biological fluids are measured using various methods, the most common of which is enzymatic immunoassay EIA/ELISA and which guide the clinicians in diagnosing and monitoring diseases that inflict biological systems. All the techniques where enzymes are employed to show antigen-antibody reactions are generally referred to as enzymatic immunoassay EIA/ELISA method. Since the basic principles of EIA and ELISA are the same. The main objective of this review is to present an overview of the historical journey that had led to the invention of EIA/ELISA, an indispensible method for medical and research laboratories, types of ELISA developed after its invention [direct (the first ELISA method invented), indirect, sandwich and competitive methods], problems encountered during peptide/protein analyses (pre-analytical, analytical and post-analytical), rules to be followed to prevent these problems, and our laboratory experience of more than 15 years. Copyright © 2015 Elsevier Inc. All rights reserved.

  17. Development of a rapid diagnostic test for pertussis: direct detection of pertussis toxin in respiratory secretions.

    PubMed Central

    Friedman, R L; Paulaitis, S; McMillan, J W

    1989-01-01

    Monoclonal antibodies (MAb) were produced against the specific Bordetella pertussis antigen pertussis toxin (PT). In preliminary studies, one MAb (IB12) was selected and used in an enzyme-linked dot blot immunoassay to evaluate the ability of the method to detect known amounts of PT in control experiments and to test its potential for direct detection of PT in nasopharyngeal secretion (NP) specimens from patients with confirmed cases of whooping cough. The dot blot assay was able to detect PT at levels as low as 10 ng per dot in either buffer or control NP specimens. The assay demonstrated specificity, reacting only with dot blots of whole B. pertussis and not Bordetella bronchiseptica, Bordetella parapertussis, or other bacterial strains. In preliminary studies, NP aspirate, swab, and wash specimens were compared. The specimen of choice was found to be the NP aspirate, for which 100% positive results were found in the assay. These initial studies suggest that the dot blot immunoassay in which a MAb is used for direct detection of PT in NP specimens may be useful as a rapid diagnostic test for pertussis. Images PMID:2808670

  18. Label-Free Quantitative Immunoassay of Fibrinogen in Alzheimer Disease Patient Plasma Using Fiber Optical Surface Plasmon Resonance

    NASA Astrophysics Data System (ADS)

    Kim, Jisoo; Kim, SeJin; Nguyen, Tan Tai; Lee, Renee; Li, Tiehua; Yun, Changhyun; Ham, Youngeun; An, Seong Soo A.; Ju, Heongkyu

    2016-05-01

    We present a real-time quantitative immunoassay to detect fibrinogen in the blood plasma of Alzheimer's disease patients using multimode fiber optical sensors in which surface plasmon resonance (SPR) was employed. Nanometer-thick bimetals including silver and aluminum were coated onto the core surface of the clad-free part (5 cm long) of the fiber for SPR excitation at the He-Ne laser wavelength of 632.8 nm. The histidine-tagged peptide was then coated on the metal surface to immobilize the fibrinogen antibody for the selective capture of fibrinogen among the proteins in the patient blood plasma. The SPR fiber optical sensor enabled quantitative detection of concentrations of fibrinogen from the different human patient blood at a detection limit of ˜20 ng/ml. We also observed a correlation in the fibrinogen concentration measurement between enzyme-linked immunosorbent assay and our SPR fiber-based sensors. This suggests that the presented SPR fiber-based sensors that do not rely on the use of labels such as fluorophores can be used for a real-time quantitative assay of a specific protein such as fibrinogen in a human blood that is known to contain many other kinds of proteins together.

  19. A New Conjugation Method Used for the Development of an Immunoassay for the Detection of Amanitin, a Deadly Mushroom Toxin.

    PubMed

    Bever, Candace S; Barnych, Bogdan; Hnasko, Robert; Cheng, Luisa W; Stanker, Larry H

    2018-06-28

    One of the deadliest mushrooms is the death cap mushroom, Amanita phalloides . The most toxic constituent is α-amanitin, a bicyclic octapeptide, which damages the liver and kidneys. To develop a new tool for detecting this toxin, polyclonal antibodies were generated and characterized. Both α- and β-amanitin were coupled to carrier proteins through four different linking chemistries, one of which has never before been described. These conjugates were evaluated for their effectiveness in generating antibodies specific for the free toxin, as well as their utility in formatting heterogeneous assays with high sensitivity. Ultimately, these efforts yielded a newly described conjugation procedure utilizing periodate oxidation followed by reductive amination that successfully resulted in generating sensitive immunoassays (limit of detection (LOD), ~1.0 µg/L). The assays were characterized for their selectivity and were found to equally detect α-, β-, and γ-amanitin, and not cross-react with other toxins tested. Toxin detection in mushrooms was possible using a simple sample preparation method. This enzyme-linked immunosorbent assay (ELISA) is a simple and fast test, and readily detects amatoxins extracted from A. phalloides .

  20. Development of highly sensitive and selective antibodies for the detection of the explosive pentaerythritol tetranitrate (PETN) by bioisosteric replacement.

    PubMed

    Hesse, Almut; Biyikal, Mustafa; Rurack, Knut; Weller, Michael G

    2016-02-01

    An improved antibody against the explosive pentaerythritol tetranitrate (PETN) was developed. The immunogen was designed by the concept of bioisosteric replacement, which led to an excellent polyclonal antibody with extreme selectivity and immunoassays of very good sensitivity. Compounds such as nitroglycerine, 2,4,6-trinitrotoluene, 1,3,5-trinitrobenzene, hexogen (RDX), 2,4,6-trinitroaniline, 1,3-dinitrobenzene, octogen (HMX), triacetone triperoxide, ammonium nitrate, 2,4,6-trinitrophenol and nitrobenzene were tested for potential cross-reactivity. The detection limit of a competitive enzyme-linked immunosorbent assay was determined to be around 0.5 µg/l. The dynamic range of the assay was found to be between 1 and 1000 µg/l, covering a concentration range of three decades. This work shows the successful application of the bioisosteric concept in immunochemistry by exchange of a nitroester to a carbonate diester. The antiserum might be used for the development of quick tests, biosensors, microtitration plate immunoassays, microarrays and other analytical methods for the highly sensitive detection of PETN, an explosive frequently used by terrorists, exploiting the extreme difficulty of its detection. Copyright © 2015 John Wiley & Sons, Ltd.

  1. Validation of a commercially available enzyme-linked immunoabsorbent assay for the quantification of human α-Synuclein in cerebrospinal fluid.

    PubMed

    Kruse, Niels; Mollenhauer, Brit

    2015-11-01

    The quantification of α-Synuclein in cerebrospinal fluid (CSF) as a biomarker has gained tremendous interest in the last years. Several commercially available immunoassays are emerging. We here describe the full validation of one commercially available ELISA assay for the quantification of α-Synuclein in human CSF (Covance alpha-Synuclein ELISA kit). The study was conducted within the BIOMARKAPD project in the European initiative Joint Program for Neurodegenerative Diseases (JPND). We investigated the effect of several pre-analytical and analytical confounders: i.e. (1) need for centrifugation of freshly drawn CSF, (2) sample stability, (3) delay of freezing, (4) volume of storage aliquots, (5) freeze/thaw cycles, (6) thawing conditions, (7) dilution linearity, (8) parallelism, (9) spike recovery, and (10) precision. None of these confounders influenced the levels of α-Synuclein in CSF significantly. We found a very high intra-assay precision. The inter-assay precision was lower than expected due to different performances of kit lots used. Overall the validated immunoassay is useful for the quantification of α-Synuclein in human CSF. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Ultrasensitive microfluidic solid-phase ELISA using an actuatable microwell-patterned PDMS chip.

    PubMed

    Wang, Tanyu; Zhang, Mohan; Dreher, Dakota D; Zeng, Yong

    2013-11-07

    Quantitative detection of low abundance proteins is of significant interest for biological and clinical applications. Here we report an integrated microfluidic solid-phase ELISA platform for rapid and ultrasensitive detection of proteins with a wide dynamic range. Compared to the existing microfluidic devices that perform affinity capture and enzyme-based optical detection in a constant channel volume, the key novelty of our design is two-fold. First, our system integrates a microwell-patterned assay chamber that can be pneumatically actuated to significantly reduce the volume of chemifluorescent reaction, markedly improving the sensitivity and speed of ELISA. Second, monolithic integration of on-chip pumps and the actuatable assay chamber allow programmable fluid delivery and effective mixing for rapid and sensitive immunoassays. Ultrasensitive microfluidic ELISA was demonstrated for insulin-like growth factor 1 receptor (IGF-1R) across at least five orders of magnitude with an extremely low detection limit of 21.8 aM. The microwell-based solid-phase ELISA strategy provides an expandable platform for developing the next-generation microfluidic immunoassay systems that integrate and automate digital and analog measurements to further improve the sensitivity, dynamic ranges, and reproducibility of proteomic analysis.

  3. A hybrid approach to urine drug testing using high-resolution mass spectrometry and select immunoassays.

    PubMed

    McMillin, Gwendolyn A; Marin, Stephanie J; Johnson-Davis, Kamisha L; Lawlor, Bryan G; Strathmann, Frederick G

    2015-02-01

    The major objective of this research was to propose a simplified approach for the evaluation of medication adherence in chronic pain management patients, using liquid chromatography time-of-flight (TOF) mass spectrometry, performed in parallel with select homogeneous enzyme immunoassays (HEIAs). We called it a "hybrid" approach to urine drug testing. The hybrid approach was defined based on anticipated positivity rates, availability of commercial reagents for HEIAs, and assay performance, particularly analytical sensitivity and specificity for drug(s) of interest. Subsequent to implementation of the hybrid approach, time to result was compared with that observed with other urine drug testing approaches. Opioids, benzodiazepines, zolpidem, amphetamine-like stimulants, and methylphenidate metabolite were detected by TOF mass spectrometry to maximize specificity and sensitivity of these 37 drug analytes. Barbiturates, cannabinoid metabolite, carisoprodol, cocaine metabolite, ethyl glucuronide, methadone, phencyclidine, propoxyphene, and tramadol were detected by HEIAs that performed adequately and/or for which positivity rates were very low. Time to result was significantly reduced compared with the traditional approach. The hybrid approach to urine drug testing provides a simplified and analytically specific testing process that minimizes the need for secondary confirmation. Copyright© by the American Society for Clinical Pathology.

  4. A highly sensitive capillary electrophoresis immunoassay strategy based on dual-labeled gold nanoparticles enhancing chemiluminescence for the detection of prostate-specific antigen.

    PubMed

    Li, Shuting; Shi, Min; Zhao, Jingjin; Zhang, Liangliang; Huang, Yong; Zhao, Shulin

    2017-07-01

    An enzyme and antibody dual labeled gold nanoparticles enhancing chemiluminescence strategy was developed for highly sensitive CE immunoassay (IA) of prostate-specific antigen (PSA). In this work, gold nanoparticles were labeled with horseradish peroxidase and antiprostate specific antigen-antibody, and used as the marker (Ab * ). After PSA (antigen, Ag) was added into the system, a noncompetitive immune reaction was happen between Ab * and Ag to form an immune complex (Ag-Ab * ). Subsequently, the obtained Ag-Ab * and unreacted Ab * were separated by CE, and the chemiluminescence intensity of Ag-Ab * was used to estimate PSA concentration. The calibration curve showed a good linearity in the range of 0.25-10 ng/mL. Based on a S/N of 3, the detection limit for PAS was estimated to be 0.092 ng/mL. Proposed CE method was applied for PSA quantification in human serum samples from healthy volunteers and patients with prostate cancer. The obtained results demonstrated that the proposed CE method may serve as an alternative tool for clinical analysis of PSA. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Alternaria and Cladosporium Fungal Allergen Epitopes are Denatured by Sodium Hypochlorite

    PubMed Central

    2009-01-01

    Background Fungal allergens are ubiquitous; however, little progress has been made understanding fungal allergenic material removal from indoor environments. Purpose We investigated removal of environmental allergenic material derived from Alternaria and Cladosporium using sodium hypochlorite in vivo and in vitro. Methods Freeze dried allergen extract from Alternaria alternata and Cladosporium herbarum was treated with hypochlorite concentrations of 322, 88, 38, 16, 3, 0.3, and 0 mM, respectively. Remaining native allergenic material was quantified using enzyme immunoassay and remaining viable fungal material was evaluated. Results The results of treating Alternaria or Cladosporium extract with sodium hypochlorite are immediate and obvious. Concentrations greater than 100 mM remove color and concentrations between 100 and 38 mM partially uncolored the extract. Immunoassay for total antigenic and allergenic material remaining after treatment with sodium hypochlorite including 2 concentrations recommended for killing fungus confirmed a general destruction of antigenic and allergenic material at concentrations of 38 mM or greater. Conclusions This work confirms the ability of solutions of sodium hypochlorite to denature fungal allergenic material from common outdoor and indoor fungi A. alternata and C. herbarum. Destruction of recognized antigenic and allergenic epitopes occurs at hypochlorite concentrations commonly used for household cleaning. PMID:23282316

  6. Preparation and Characteristic of Dextran-BSA Antibody and Establishment of its ELISA Immunoassay.

    PubMed

    Xie, Zhen-ming; Yu, Lin; Fang, Li-sha

    2015-01-01

    The enzyme-linked immunosorbent assay (ELISA) is a potential tool for the determination of dextran. In this study, dextran neoglycoprotein antigens were prepared by Reductive Amination method, and were confirmed by SDS-PAGE and free amino detection. The impact factors such as different oxidation degree of dextran, the conjugate reaction time to BSA were investigated. The best preparation conditions were obtained (n(dextran)/n(oxidant) of NaIO4 = 1/120, the reaction time of 24 h), and the antigen with best combination with standard was obtained. The antigens interacted with standard antibody and were evaluated through ELISA. The immunogen was immunized with white rabbits to obtained antibody, respectively. A general and broad class-specific ELISA immunoassay was developed for dextran detection according to ELISA theory. The optimized conditions of assay used coating antigen at 10 μg/mL, reaction time of antibody and rabbit-anti-bovine IgG in 45 min, blocking reagents with 5% calf serum. The developed ELISA detection method with good linear and accuracy was put to use for quantitative analysis of dextran T40 in commercial sugarpractical for detection of dextran.

  7. Assessment of pregnancy status of Asian elephants (Elephas maximus) by measurement of progestagen and glucocorticoid and their metabolite concentrations in serum and feces, using enzyme immunoassay (EIA).

    PubMed

    Kajaysri, Jatuporn; Nokkaew, Weerapun

    2014-03-01

    The study was to find patterns of progestagen (progesterone and its metabolite) and glucocorticoid and their metabolite concentrations in serum and feces of pregnant Asian elephants (Elephas maximus). The 5 female Asian domestic elephants were naturally mated until pregnancy. After that, blood and feces samples were collected monthly during pregnancy for progestagen, glucocorticoid and their metabolites analysis by enzyme immunoassay (EIA). The results showed the serum progestagen concentration during gestation was 2.11 ± 0.60 to 18.44 ± 2.28 ng/ml. Overall, serum progestagen concentration rose from the 1st month to reach peak in the 11th month, after which it declined to its lowest level in the 22nd month of pregnancy. Fecal progestagen concentration varied from 1.18 ± 0.54 to 3.35 ± 0.45 µg/g during pregnancy. In general, fecal progestagen concentration increased from the 1st month to its highest level in the 12th month. After this, it declined reaching its lowest point in the 22nd month of pregnancy. Glucocorticoid hormones and their metabolite concentrations both in serum and feces fluctuated from low to medium throughout almost the entire pregnancy period and then rapidly increased around the last week before calving. Our study suggests that this profile of progestagen and glucocorticoid hormones and their metabolite concentration levels in serum and feces can be used to assess the pregnancy status of Asian elephants. If serum and fecal progestagen concentrations were found in very low levels and glucocorticoid and their metabolite concentrations were found in very high levels, it was indicated that the cow elephant would calve within 7 days.

  8. Comparison of clinical performance of antigen based-enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-PCR for detection of genital Chlamydia trachomatis infection.

    PubMed

    Nateghi Rostami, Mahmoud; Hossein Rashidi, Batool; Aghsaghloo, Fatemeh; Nazari, Razieh

    2016-06-01

    Chlamydia trachomatis is the most common sexually transmitted bacterial pathogen worldwide. Early detection and treatment of C.trachomatis genital infection prevent serious reproductive complications. Performances of enzyme immunoassay (EIA) and major outer membrane protein (MOMP)-polymerase chain reaction (PCR) for diagnosis of genital C.trachomatis infection in women were compared. In this cross sectional study a total of 518 women volunteers were included (33.67±8.3 yrs) who had been referred to Gynecology clinics of Qom province, Iran, were included. Endocervical swab specimens were collected to detect lipopolysaccharide (LPS) antigen in EIA and to amplify MOMP gene of C.trachomatis in PCR. Results were confirmed using ompI nested-PCR. Sensitivity, specificity, positive (PPV) and negative predictive values (NPV) were calculated for performance of the tests. Odds ratios were determined using binary logistic regression analysis. In total, 37 (7.14%) cases were positive by EIA and/or MOMP-PCR. All discrepant results were confirmed by nested-PCR. Sensitivity, specificity, PPV and NPV values of EIA were 59.46%, 100%, 100% and 96.98%, and those of MOMP-PCR were 97.30%, 100%, 100%, 99.79%, respectively. Reproductive complications including 2.7% ectopic pregnancy, 5.4% stillbirth, 5.4% infertility, and 10.8% PROM were recorded. The risk of developing chlamydiosis was increased 4.8-fold in volunteers with cervicitis (p<0.05; OR 4.80; 95% CI 1.25-18.48). C.trachomatis infection should be regarded in women of reproductive ages especially those with cervicitis. Primary screening of women by using the low cost antigen-EIA is recommended; however, due to the low sensitivity of Ag-EIA, verification of the negative results by a DNA amplification method is needed.

  9. Usefulness of enzyme immunoassay (EIA) for screening of anti HIV antibodies in urinary specimens: A comparative analysis.

    PubMed

    Sahni, A K; Nagendra, A; Roy, Partha; Patrikar, S

    2014-07-01

    Standard HIV testing is done using serum or plasma. FDA approved ELISA to screen urine for IgG antibodies to HIV-1 in 1996. It is a simple, noninvasive test and is appropriate for developing countries where health care personnel may not be professionally trained or where clean needles for drawing blood may not always be available. 436 individuals with high-risk behavior and strong clinical suspicion of HIV infection were screened for IgG antibodies to HIV-1 in urine by ELISA. Urine HIV testing was performed by enzyme immunoassay, at the ongoing Voluntary Confidential Counseling and Testing Center (VCCTC) at a large tertiary care microbiology lab. The individuals enrolled for the study had high-risk exposure to the virus and majorities were from a state with a high incidence of HIV infection. In all individuals, both serum and urine were tested for IgG antibodies to HIV-1. Overall, 135 individuals (30.96%) were HIV-positive, of whom 96 (71%) had never previously tested positive; 87% of those who tested positive received their results, and most were referred for medical care. Sensitivity, specificity and predictive values of HIV-1 urine ELISA test kit were determined. Sensitivity was found to be 89.6%; 95% CI [82.9-94.0], specificity 97.3%; 95% CI [94.6-98.8], positive predictive value 93.8%; 95% CI [87.8-97.1] and negative predictive value 95.4%; 95% CI [92.3-97.4]. Efficiency, sensitivity, and specificity of the urine-based screening for HIV-1 test kits were excellent as compared to the reference test.

  10. Use of a nested PCR-enzyme immunoassay with an internal control to detect Chlamydophila psittaci in turkeys

    PubMed Central

    Van Loock, Marnix; Verminnen, Kristel; Messmer, Trudy O; Volckaert, Guido; Goddeeris, Bruno M; Vanrompay, Daisy

    2005-01-01

    Background Laboratory diagnosis of Chlamydophila psittaci, an important turkey respiratory pathogen, is difficult. To facilitate the diagnosis, a nested PCR-enzyme immunoassay (PCR-EIA) was developed to detect the Cp. psittaci outer membrane protein A (ompA) gene in pharyngeal swabs. Methods The fluorescein-biotin labelled PCR products were immobilized on streptavidin-coated microtiter plates and detected with anti-fluorescein peroxidase conjugate and a colorimetric substrate. An internal inhibition control was included to rule out the presence of inhibitors of DNA amplification. The diagnostic value of the ompA nested PCR-EIA in comparison to cell culture and a 16S-rRNA based nested PCR was assessed in pharyngeal turkey swabs from 10 different farms experiencing respiratory disease. Results The sensitivity of the nested PCR-EIA was established at 0.1 infection forming units (IFU). Specificity was 100%. The ompA nested PCR-EIA was more sensitive than the 16S-rRNA based nested PCR and isolation, revealing 105 out of 200 (52.5%) positives against 13 and 74 for the latter two tests, respectively. Twenty-nine (23.8%) out of 122 ompA PCR-EIA negatives showed the presence of inhibitors of DNA amplification, although 27 of them became positive after diluting (1/10) the specimens in PCR buffer or after phenol-chloroform extraction and subsequent ethanol precipitation. Conclusion The present study stresses the need for an internal control to confirm PCR true-negatives and demonstrates the high prevalence of chlamydiosis in Belgian turkeys and its potential zoonotic risk. The ompA nested PCR-EIA described here is a rapid, highly sensitive and specific diagnostic assay and will help to facilitate the diagnosis of Cp. psittaci infections in both poultry and man. PMID:16185353

  11. Variation in the limit-of-detection of the ProSpecT Campylobacter microplate enzyme immunoassay in stools spiked with emerging Campylobacter species.

    PubMed

    Bojanić, Krunoslav; Midwinter, Anne Camilla; Marshall, Jonathan Craig; Rogers, Lynn Elizabeth; Biggs, Patrick Jon; Acke, Els

    2016-08-01

    Campylobacter enteritis in humans is primarily associated with C. jejuni/coli infection. The impact of other Campylobacter spp. is likely to be underestimated due to the bias of culture methods towards Campylobacter jejuni/coli diagnosis. Stool antigen tests are becoming increasingly popular and appear generally less species-specific. A review of independent studies of the ProSpecT® Campylobacter Microplate enzyme immunoassay (EIA) developed for C. jejuni/coli showed comparable diagnostic results to culture methods but the examination of non-jejuni/coli Campylobacter spp. was limited and the limit-of-detection (LOD), where reported, varied between studies. This study investigated LOD of EIA for Campylobacter upsaliensis, Campylobacter hyointestinalis and Campylobacter helveticus spiked in human stools. Multiple stools and Campylobacter isolates were used in three different concentrations (10(4)-10(9)CFU/ml) to reflect sample heterogeneity. All Campylobacter species evaluated were detectable by EIA. Multivariate analysis showed LOD varied between Campylobacter spp. and faecal consistency as fixed effects and individual faecal samples as random effects. EIA showed excellent performance in replicate testing for both within and between batches of reagents, in agreement between visual and spectrophotometric reading of results, and returned no discordance between the bacterial concentrations within independent dilution test runs (positive results with lower but not higher concentrations). This study shows how limitations in experimental procedures lead to an overestimation of consistency and uniformity of LOD for EIA that may not hold under routine use in diagnostic laboratories. Benefits and limitations for clinical practice and the influence on estimates of performance characteristics from detection of multiple Campylobacter spp. by EIA are discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  12. Phase 1 first-in-human studies of the reactogenicity and immunogenicity of a recombinant meningococcal NspA vaccine in healthy adults.

    PubMed

    Halperin, Scott A; Langley, Joanne M; Smith, Bruce; Wunderli, Peter; Kaufman, Lisa; Kimura, Alan; Martin, Denis

    2007-01-05

    Neisserial surface protein A (NspA) is a highly conserved, surface-exposed outer membrane protein of Neisseria meningitidis that has been shown to induce a bactericidal immune response in animals against all pathogenic Neisserial serogroups. Healthy 18-50-year-old adults were assigned to receive, in a dose escalating manner, 3 doses of 1 of 5 formulations of an experimental, unfolded, recombinant NspA (rNspA) vaccine or placebo, or 1 dose of commercially available quadravalent (A, C, Y, W-135) meningococcal polysaccharide vaccine (Menomune((R))). Adverse events were collected during the first week post-immunization, prior to the next dose and 1 month after the last dose. Serum for measurement of hematological and biochemical parameters and antibodies by enzyme immunoassay and bactericidal assay were measured before the first dose, prior to the second dose and 1 month after the last dose of vaccine. The rNspA vaccine was well tolerated by recipients. Injection-site pain was reported more frequently by recipients of the three highest doses of rNspA compared to placebo but at similar rates to the licensed meningococcal polysaccharide vaccine. Adverse events were reported less frequently after subsequent doses in the three-dose series. An antibody rise measured by enzyme immunoassay was elicited with a dose-related increase that reached a maximum with the 125mug dose. Prolongation of the dosing interval between the second and third dose appeared to be associated with increased antibody levels. No bactericidal antibodies were detected after any of the rNspA formulations. The unfolded rNspA meningococcal vaccine was well tolerated and immunogenic in healthy adult volunteers but did not elicit bactericidal antibodies.

  13. Effects of a cyclic NSAID regimen on levels of gingival crevicular fluid prostaglandin E2and Interleukin-1β: A 6-month randomized controlled clinical trial.

    PubMed

    Oduncuoglu, B F; Kayar, N A; Haliloglu, S; Serpek, B; Ataoglu, T; Alptekin, N O

    2018-05-01

    Nonsteroidal anti-inflammatory drugs (NSAIDs) are widely used for inflammation control and pain relief. However, while the adjunct use of NSAIDs is avoided for periodontal therapy because of related side effects, cyclic administration of NSAIDs may reduce or eliminate these effects. We evaluated the effect of a cyclic diclofenac potassium (DP) regimen on clinical parameters and levels of prostaglandin E 2 (PGE 2 ) and interleukin-1β (IL-1β) in the gingival crevicular fluid (GCF) of individuals with periodontitis. The study protocol was approved by the Ethics Committee (2000/071). Forty-one individuals with chronic periodontitis (33 men, 8 women) were divided into two groups (test and control) after initial periodontal therapy. During this 6-month, randomized, double-blind, placebo-controlled study, test (n = 28) and control (n = 13) groups were administered a cyclic regimen of DP (50 mg, twice daily) or placebo. Clinical measurements and GCF sample collections were made at baseline, 2, 4, and 6 months. GCF levels of PGE 2 and IL-1β were determined using enzyme immunoassay and enzyme-linked immunoassay kits, respectively. At baseline, no significant differences existed between groups for plaque indices, gingival indices, bleeding on probing, probing depth (PD), or attachment levels (P > 0.05). Compared with the control group, cyclic regimen in the test group suppressed increased levels of PGE 2 found in GCF at the end of the study (P < 0.05). Significant differences for PD and relative attachment gain were also noted in favor of the test group (P < 0.05). These results suggest that a cyclic regimen of DP may be efficacious in the management of chronic periodontitis in adults.

  14. Characterisation and validation of an enzyme-immunoassay for the non-invasive assessment of faecal glucocorticoid metabolites in cheetahs (Acinonyx jubatus).

    PubMed

    Ludwig, C; Wachter, B; Silinski-Mehr, S; Ganswindt, A; Bertschinger, H; Hofer, H; Dehnhard, M

    2013-01-01

    The non-invasive measurement of adrenocortical function in cheetahs is an important tool to assess stress in captive and free-ranging individuals, because stress has been suggested to be one of the causes of poor reproductive performance of captive cheetahs. We tested four enzyme immunoassays (EIA) in two captive cheetahs in Germany using adrenocorticotropic hormone (ACTH) challenges and identified the corticosterone-3-CMO EIA to be most sensitive to the increase in faecal glucocorticoid metabolite (fGCM) concentrations after the ACTH challenge. This EIA performed also well in five captive cheetahs in South Africa. The fGCM concentrations across all seven cheetahs increased within 24h by 681% compared to the baseline levels prior to ACTH. Storage of faecal samples at 0-4°C did not strongly affect fGCM concentrations within 24h, simplifying sample collection when immediate storage at -20°C is not feasible. The two cheetahs in Germany also received an injection of [(3)H]cortisol to characterise fGCMs in faecal extracts using high-performance liquid chromatography (HPLC) immunograms. HPLC fractions were measured for their radioactivity and immunoreactive fGCM concentrations with the corticosterone-3-CMO EIA, respectively. The results revealed a polar peak of radiolabelled cortisol metabolites co-eluting with the major peak of immunoreactive fGCMs. Thus, our EIA measured substantial amounts of fGCMs corresponding to the radioactive peaks. The peaks were of higher polarity than native cortisol and corticosterone, suggesting that the metabolites were conjugated, which was confirmed by solvolysis of the HPLC fractions. Our results show that the corticosterone-3-CMO EIA is a reliable tool to assess fGCMs in cheetahs. Copyright © 2012 Elsevier Inc. All rights reserved.

  15. Evaluation of the highly sensitive chemiluminescent enzyme immunoassay "Lumipulse HBsAg-HQ" for hepatitis B virus screening.

    PubMed

    Deguchi, Matsuo; Kagita, Masanori; Yoshioka, Nori; Tsukamoto, Hiroko; Takao, Miyuki; Tahara, Kazuko; Maeda, Ikuhiro; Hidaka, Yoh; Yamauchi, Satoshi; Kaneko, Atsushi; Miyakoshi, Hideo; Isomura, Mitsuo

    2017-10-06

    Ongoing efforts in the development of HBsAg detection kits are focused on improving sensitivity and specificity. The purpose of this study was to evaluate an improved, highly sensitive quantitative assay, "Lumipulse HBsAg-HQ", a chemiluminescent enzyme immunoassay designed for a fully automated instrument, the "Lumipulse G1200". Serum samples for reproducibility, dilution, correlation, sensitivity, and specificity studies were obtained from patients at the Osaka University Hospital. Seroconversion and sensitivity panels were purchased from a commercial vender. Subtype, sensitivity panels, and HBsAg recombinant proteins with one or two amino acid substitutions were prepared in-house. The coefficients of variation for the low, medium, and high concentration samples ranged from 1.93 to 2.55%. The HBsAg-HQ reagent for dilution testing showed good linearity in the 0.005-150 HBsAg IU/mL range and no prozone phenomenon. All 102 HBV carrier samples were positive by HBsAg-HQ, while other commercial reagents showed one or more to be negative. In the seroconversion panel, the 14-day blood sample was positive. The sensitivity against HBsAg-HQ "ad" and "ay" subtypes was 0.025 ng/mL. Comparisons among the HBsAg-HQ, HISCL, and Architect HBsAg reagents were performed using the Bland-Altman plot. Specificity for 1000 seronegative individuals was 99.7%. HBsAg-HQ detected 29 positive serum among 12 231 routinely obtained serum samples, which showed concentrations of 0.005-0.05 HBsAg IU/mL. According to these results, the Lumipulse HBsAg-HQ assay, with a highly sensitive limit of detection of 0.005 IU/mL, may facilitate the development of a better management strategy for a considerable proportion of infected patients. © 2017 Wiley Periodicals, Inc.

  16. Development of an enzyme-linked immunosorbent assay for detection of clopidol residues in chicken tissues.

    PubMed

    Jiang, Jin-Qing; Zhang, Hai-Tang; Zhang, Hui-Hui; Wang, Zi-Liang; Yang, Xue-Feng; Fan, Guo-Ying

    2014-08-01

    Clopidol is mainly used for the prevention and treatment of coccidiosis, which poses a serious potential hazard to public health, in veterinary medicine. The aim of this study was to prepare monoclonal antibodies (mAbs) against clopidol (CLOP) and develop an immunoassay for detecting CLOP residues in chicken tissues. After derivation, CLOP hapten was conjugated to carrier proteins to synthesize the artificial antigen, and immunized Balb/C mice were employed to screen mAbs. A sensitive hybridoma named C1G3 was screened out and two indirect competitive enzyme-linked immunosorbent assay (icELISA) standard curves were established. For the traditional two-step assay the linear range was from 0.06 to 98 ng mL(-1) , with half-maximal inhibitory concentration (IC50 ) and limit of detection (LOD) values of 2.76 ng mL(-1) and 0.03 ng mL(-1) respectively, while the rapid one-step icELISA had a working range from 0.08 to 102 ng mL(-1) , with IC50 and LOD values of 3.52 ng mL(-1) and 0.03 ng mL(-1) respectively. It was also indicated that a 10-fold dilution in chicken muscles gave an inhibition curve almost the same as that obtained in phosphate-buffered saline. When applied to spiking tests in chicken samples, the correlation coefficient (R(2) ) between concentrations added and measured was 0.9534. The results of this study suggest that the immunoassay described is a promising alternative for screening CLOP residues in biological matrices and is suitable for routine diagnostics. © 2014 Society of Chemical Industry.

  17. Performance of the fourth-generation Bio-Rad GS HIV Combo Ag/Ab enzyme immunoassay for diagnosis of HIV infection in Southern Africa

    PubMed Central

    Piwowar-Manning, Estelle; Fogel, Jessica M.; Richardson, Paul; Wolf, Shauna; Clarke, William; Marzinke, Mark A.; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K.K.; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J.; Eshleman, Susan H.

    2015-01-01

    Background Fourth-generation HIV assays detect both antigen and antibody, facilitating detection of acute/early HIV infection. The Bio-Rad GS HIV Combo Ag/Ab assay (Bio-Rad Combo) is an enzyme immunoassay that simultaneously detects HIV p24 antigen and antibodies to HIV-1 and HIV-2 in serum or plasma. Objective To evaluate the performance of the Bio-Rad Combo assay for detection of HIV infection in adults from Southern Africa. Study design Samples were obtained from adults in Soweto and Vulindlela, South Africa and Dar es Salaam, Tanzania (300 HIV-positive samples; 300 HIV-negative samples; 12 samples from individuals previously classified as having acute/early HIV infection). The samples were tested with the Bio-Rad Combo assay. Additional testing was performed to characterize the 12 acute/early samples. Results All 300 HIV-positive samples were reactive using the Bio-Rad Combo assay; false positive test results were obtained for 10 (3.3%) of the HIV-negative samples (sensitivity: 100%, 95% confidence interval [CI]: 98.8–100%); specificity: 96.7%, 95% CI: 94.0–98.4%). The assay detected 10 of the 12 infections classified as acute/early. The two infections that were not detected had viral loads < 400 copies/mL; one of those samples contained antiretroviral drugs consistent with antiretroviral therapy. Conclusions The Bio-Rad Combo assay correctly classified the majority of study specimens. The specificity reported here may be higher than that seen in other settings, since HIV-negative samples were pre-screened using a different fourth-generation test. The assay also had high sensitivity for detection of acute/early infection. False-negative test results may be obtained in individuals who are virally suppressed. PMID:25542477

  18. Characterization and Comparison of Galactomannan Enzyme Immunoassay and Quantitative Real-Time PCR Assay for Detection of Aspergillus fumigatus in Bronchoalveolar Lavage Fluid from Experimental Invasive Pulmonary Aspergillosis

    PubMed Central

    Francesconi, Andrea; Kasai, Miki; Petraitiene, Ruta; Petraitis, Vidmantas; Kelaher, Amy M.; Schaufele, Robert; Hope, William W.; Shea, Yvonne R.; Bacher, John; Walsh, Thomas J.

    2006-01-01

    Bronchoalveolar lavage (BAL) is widely used for evaluation of patients with suspected invasive pulmonary aspergillosis (IPA). However, the diagnostic yield of BAL for detection of IPA by culture and direct examination is limited. Earlier diagnosis may be facilitated by assays that can detect Aspergillus galactomannan antigen or DNA in BAL fluid. We therefore characterized and compared the diagnostic yields of a galactomannan enzyme immunoassay (GM EIA), quantitative real-time PCR (qPCR), and quantitative cultures in experiments using BAL fluid from neutropenic rabbits with experimentally induced IPA defined as microbiologically and histologically evident invasion. The qPCR assay targeted the rRNA gene complex of Aspergillus fumigatus. The GM EIA and qPCR assay were characterized by receiver operator curve analysis. With an optimal cutoff of 0.75, the GM EIA had a sensitivity and specificity of 100% in untreated controls. A decline in sensitivity (92%) was observed when antifungal therapy (AFT) was administered. The optimal cutoff for qPCR was a crossover of 36 cycles, with sensitivity and specificity of 80% and 100%, respectively. The sensitivity of qPCR also decreased with AFT to 50%. Quantitative culture of BAL had a sensitivity of 46% and a specificity of 100%. The sensitivity of quantitative culture decreased with AFT to 16%. The GM EIA and qPCR assay had greater sensitivity than culture in detection of A. fumigatus in BAL fluid in experimentally induced IPA (P ± 0.04). Use of the GM EIA and qPCR assay in conjunction with culture-based diagnostic methods applied to BAL fluid could facilitate accurate diagnosis and more-timely initiation of specific therapy. PMID:16825367

  19. Comparison between the two-step and the three-step algorithms for the detection of toxigenic Clostridium difficile.

    PubMed

    Qutub, M O; AlBaz, N; Hawken, P; Anoos, A

    2011-01-01

    To evaluate usefulness of applying either the two-step algorithm (Ag-EIAs and CCNA) or the three-step algorithm (all three assays) for better confirmation of toxigenic Clostridium difficile. The antigen enzyme immunoassays (Ag-EIAs) can accurately identify the glutamate dehydrogenase antigen of toxigenic and nontoxigenic Clostridium difficile. Therefore, it is used in combination with a toxin-detecting assay [cell line culture neutralization assay (CCNA), or the enzyme immunoassays for toxins A and B (TOX-A/BII EIA)] to provide specific evidence of Clostridium difficile-associated diarrhoea. A total of 151 nonformed stool specimens were tested by Ag-EIAs, TOX-A/BII EIA, and CCNA. All tests were performed according to the manufacturer's instructions and the results of Ag-EIAs and TOX-A/BII EIA were read using a spectrophotometer at a wavelength of 450 nm. A total of 61 (40.7%), 38 (25.3%), and 52 (34.7%) specimens tested positive with Ag-EIA, TOX-A/BII EIA, and CCNA, respectively. Overall, the sensitivity, specificity, negative predictive value, and positive predictive value for Ag-EIA were 94%, 87%, 96.6%, and 80.3%, respectively. Whereas for TOX-A/BII EIA, the sensitivity, specificity, negative predictive value, and positive predictive value were 73.1%, 100%, 87.5%, and 100%, respectively. With the two-step algorithm, all 61 Ag-EIAs-positive cases required 2 days for confirmation. With the three-step algorithm, 37 (60.7%) cases were reported immediately, and the remaining 24 (39.3%) required further testing by CCNA. By applying the two-step algorithm, the workload and cost could be reduced by 28.2% compared with the three-step algorithm. The two-step algorithm is the most practical for accurately detecting toxigenic Clostridium difficile, but it is time-consuming.

  20. Determination of HIV Status in African Adults With Discordant HIV Rapid Tests.

    PubMed

    Fogel, Jessica M; Piwowar-Manning, Estelle; Donohue, Kelsey; Cummings, Vanessa; Marzinke, Mark A; Clarke, William; Breaud, Autumn; Fiamma, Agnès; Donnell, Deborah; Kulich, Michal; Mbwambo, Jessie K K; Richter, Linda; Gray, Glenda; Sweat, Michael; Coates, Thomas J; Eshleman, Susan H

    2015-08-01

    In resource-limited settings, HIV infection is often diagnosed using 2 rapid tests. If the results are discordant, a third tie-breaker test is often used to determine HIV status. This study characterized samples with discordant rapid tests and compared different testing strategies for determining HIV status in these cases. Samples were previously collected from 173 African adults in a population-based survey who had discordant rapid test results. Samples were classified as HIV positive or HIV negative using a rigorous testing algorithm that included two fourth-generation tests, a discriminatory test, and 2 HIV RNA tests. Tie-breaker tests were evaluated, including rapid tests (1 performed in-country), a third-generation enzyme immunoassay, and two fourth-generation tests. Selected samples were further characterized using additional assays. Twenty-nine samples (16.8%) were classified as HIV positive and 24 of those samples (82.8%) had undetectable HIV RNA. Antiretroviral drugs were detected in 1 sample. Sensitivity was 8.3%-43% for the rapid tests; 24.1% for the third-generation enzyme immunoassay; 95.8% and 96.6% for the fourth-generation tests. Specificity was lower for the fourth-generation tests than the other tests. Accuracy ranged from 79.5% to 91.3%. In this population-based survey, most HIV-infected adults with discordant rapid tests were virally suppressed without antiretroviral drugs. Use of individual assays as tie-breaker tests was not a reliable method for determining HIV status in these individuals. More extensive testing algorithms that use a fourth-generation screening test with a discriminatory test and HIV RNA test are preferable for determining HIV status in these cases.

  1. Evaluation of an enzyme immunoassay system for measuring herpes simplex virus (HSV) type 1-specific and HSV type 2-specific IgG antibodies.

    PubMed

    Prince, H E; Ernst, C E; Hogrefe, W R

    2000-01-01

    MRL Diagnostics has developed a dual enzyme immunoassay (EIA) system that employs the recombinant Herpes Simplex Virus (HSV) type-specific glycoproteins G1 (HSV1) and G2 (HSV2) to detect HSV type-specific IgG antibodies. This system was evaluated using 155 consecutive sera previously tested in a conventional dual EIA system (Zeus) that employs multiple HSV1 and HSV2 proteins to detect type-common as well as type-specific antibodies. Sera were also analyzed by Western blot to determine the true HSV type-specific IgG reactivity pattern. Of 110 sera giving concordant reactivity patterns in the MRL and Zeus EIA systems, 108 (98%) also displayed concordant Western blot patterns; two sera gave false positive HSV2 reactivity in both EIA systems. Of 45 sera giving discordant MRL and Zeus EIA reactivity patterns, 41 (91%) displayed a Western blot reactivity pattern that matched the MRL reactivity pattern. Both the HSV1 IgG component and the HSV2 IgG component of the MRL EIA system were 100% sensitive and > 95% specific. In contrast, the Zeus HSV1 IgG EIA was 98% sensitive and 79% specific, and the Zeus HSV2 IgG EIA was 85% sensitive and 79% specific. An analysis of the distribution of index values in the MRL EIA system showed that low-positive values (1.0-3.0) were rare, but, when detected, often represented false positive results; only 11 MRL low-positive results were observed, but all 6 MRL false positive results were found within this low-positive subgroup. These findings show that the MRL dual EIA system effectively detects HSV type-specific IgG antibodies. Copyright 2000 Wiley-Liss, Inc.

  2. Fungal extracellular polysaccharides in house dust as a marker for exposure to fungi: relations with culturable fungi, reported home dampness, and respiratory symptoms.

    PubMed

    Douwes, J; van der Sluis, B; Doekes, G; van Leusden, F; Wijnands, L; van Strien, R; Verhoeff, A; Brunekreef, B

    1999-03-01

    Epidemiologic studies have demonstrated an association between indoor fungal growth and respiratory symptoms. However, in only a few studies was fungal exposure actually measured. The purpose of this study was to evaluate the measurement by enzyme immunoassay of extracellular polysaccharides of Aspergillus and Penicillium species (EPS-Asp/Pen ) in house dust as a marker for fungal exposure and to study the relations between EPS-Asp/Pen levels and home dampness and respiratory symptoms in children. Extracts of house dust samples from bedroom and living room floors and mattresses from homes of 31 children with chronic respiratory symptoms and 29 children with no chronic respiratory symptoms were analyzed for EPS-Asp/Pen. EPS-Asp/Pen were readily detectable (40 to 46,513 nanogram equivalent/g dust) in 161 house dust extracts, with highest concentrations in living room floor dust. EPS-Asp/Pen levels were 2 to 3 times higher on carpeted floors than on smooth floors. EPS-Asp/Pen were significantly correlated with total culturable fungi (r = 0.3 to 0.5) and with house dust mite allergens (r = 0.3 to 0.5). EPS-Asp/Pen levels in living room floor dust were positively associated with occupant-reported home dampness. This was not observed for EPS-Asp/Pen in bedroom floor and mattress dust. EPS-Asp/Pen levels in living room floor dust were positively associated with respiratory symptoms. EPS-Asp/Pen in bedroom floor and mattress dust showed a reversed association with respiratory symptoms, possibly because of allergen-avoidance measures taken in the bedroom. The enzyme immunoassay for fungal EPS-Asp/Pen may be a useful method for exposure assessment of indoor fungi.

  3. Large-Scale Evaluation of the Immuno-Mycologics Lateral Flow and Enzyme-Linked Immunoassays for Detection of Cryptococcal Antigen in Serum and Cerebrospinal Fluid

    PubMed Central

    Hansen, Jessica; Slechta, E. Susan; Gates-Hollingsworth, Marcellene A.; Neary, Brandon; Barker, Adam P.; Bauman, Sean; Kozel, Thomas R.

    2013-01-01

    Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results. PMID:23114703

  4. Large-scale evaluation of the immuno-mycologics lateral flow and enzyme-linked immunoassays for detection of cryptococcal antigen in serum and cerebrospinal fluid.

    PubMed

    Hansen, Jessica; Slechta, E Susan; Gates-Hollingsworth, Marcellene A; Neary, Brandon; Barker, Adam P; Bauman, Sean; Kozel, Thomas R; Hanson, Kimberly E

    2013-01-01

    Cryptococcosis is a systemic infection caused by the pathogenic yeasts Cryptococcus neoformans and C. gattii. Detection of cryptococcal capsular antigen (CrAg) in serum and cerebrospinal fluid (CSF) plays an important diagnostic role. We prospectively compared the new Immuno-Mycologics Inc. (IMMY) lateral flow assay (LFA) and enzyme immunoassay (EIA) to our current CrAg test (Premier EIA; Meridian Bioscience Inc.). Discordant samples were retested with the latex-Cryptococcus antigen test (IMMY) and using serotype-specific monoclonal antibodies (MAbs). A total of 589 serum and 411 CSF specimens were tested in parallel. Qualitative agreement across assays was 97.7%. In all, 56 (41 serum and 15 CSF) samples were positive and 921 (527 serum and 394 CSF) samples were negative by all three assays. The 23 discrepant specimens were all Meridian EIA negative. Of 23 discordant specimens, 20 (87.0%) were positive by both the IMMY LFA and EIA, 2 were LFA positive only, and 1 was EIA positive only. Eleven discrepant specimens had adequate volume for latex agglutination (LA) testing; 8 were LA positive, and 3 were LA negative. LA-negative samples (2 CSF samples and 1 serum) had low IMMY LFA/EIA titers (≤1:10). Serotype-specific MAb analysis of the LA-positive samples suggested that these specimens contained CrAg epitopes similar to those of serotype C strains. In conclusion, the IMMY assays showed excellent overall concordance with the Meridian EIA. Assay performance differences were related to issues of analytic sensitivity and possible serotype bias. Incomplete access to patient-level data combined with low specimen volumes limited our ability to fully resolve discrepant results.

  5. Anti-colitis and -adhesion effects of daikenchuto via endogenous adrenomedullin enhancement in Crohn's disease mouse model.

    PubMed

    Kono, Toru; Kaneko, Atsushi; Hira, Yoshiki; Suzuki, Tatsuya; Chisato, Naoyuki; Ohtake, Nobuhiro; Miura, Naoko; Watanabe, Tsuyoshi

    2010-06-01

    Adrenomedullin (ADM) is a member of the calcitonin family of regulatory peptides, and is reported to have anti-inflammatory effects in animal models of Crohn's disease (CD). We investigated the therapeutic effects of daikenchuto (DKT), an extracted Japanese herbal medicine, on the regulation of endogenous ADM in the gastrointestinal tract in a CD mouse model. Colitis was induced in mice by intrarectal instillation of 2,4,6-trinitrobenzenesulfonic acid (TNBS); afterwards, DKT was given orally. Colonic damage was assessed on day 3 by macroscopic and microscopic observation, enzyme immunoassays of proinflammatory cytokines in the colonic mucosa, and serum amyloid A (SAA), a hepatic acute-phase protein. To determine the involvement of ADM, an ADM antagonist was instilled intrarectally before DKT administration. The effect of DKT on ADM production by intestinal epithelial cells was evaluated by enzyme immunoassay and real-time PCR. DKT significantly attenuated mucosal damage and colonic inflammatory adhesions, and inhibited elevations of SAA in plasma and the proinflammatory cytokines TNFα and IFNγ in the colon. Small and large intestinal epithelial cells produced higher levels of ADM after DKT stimulation. A DKT-treated IEC-6 cell line also showed enhanced ADM production at protein and mRNA levels. Abolition of this effect by pretreatment with an ADM antagonist shows that DKT appears to exert its anti-colitis effect via up-regulation of endogenous ADM in the intestinal tract. DKT exerts beneficial effects in a CD mouse model through endogenous release and production of ADM. Endogenous ADM may be a therapeutic target for CD. Copyright © 2009 European Crohn's and Colitis Organisation. Published by Elsevier B.V. All rights reserved.

  6. Evaluation of the Specificity of Two Enzyme Immunoassays for Coccidioidomycosis by Using Sera from a Region of Endemicity and a Region of Nonendemicity

    PubMed Central

    Ahn, YoonJi; McCotter, Orion; Gade, Lalitha; Hurst, Steven F.; Brandt, Mary E.; Park, Benjamin J.; Litvintseva, Anastasia P.

    2015-01-01

    Coccidioidomycosis (CM), a serious life-threatening fungal infection endemic to arid regions of the western United States and Mexico, can be challenging to diagnose in a timely manner. Commercially developed enzyme immunoassays (EIAs) (from Meridian Biosciences and Immuno-Mycologics [IMMY]) have provided faster, simpler means for serodiagnosis; however, independent evaluations have questioned EIA specificity, particularly IgM-positive/IgG-negative results. This study was conducted to evaluate EIA specificity among persons residing in Puerto Rico (n = 534), where CM is not endemic (who were not likely to have been exposed to Coccidioides spp.), compared to blood bank donors residing in Arizona (n = 1,218), where CM is endemic. Upon comparing serum reactivity between Puerto Rico and Arizona, the Meridian EIA showed a significant difference in IgG reactivity (0.37% versus 3.6%; P < 0.001) but not IgM reactivity (3.4% versus 2.4%; P = 0.31). No IgM-/IgG-reactive sera were detected among sera from Puerto Rico, compared to 7 (0.57%) sera from Arizona. Similar results were observed using the IMMY EIA, although significantly (P = 0.03) fewer IgM-reactive sera from Arizona were observed, compared to the Meridian EIA. EIA-reactive sera were also evaluated by immunodiffusion before and after 3- to 4-fold concentration of the sera. These results demonstrate that elevated IgG EIA reactivity is present in sera from healthy individuals in regions of endemicity and that IgM EIA reactivity observed in sera from individuals residing outside regions of endemicity is most likely nonspecific. Other criteria, including clinical and microbiological evaluations, should be taken into account when interpreting results from surveillance studies and other reporting measures. PMID:26245352

  7. Evaluation of Correlation between Pretest Probability for Clostridium difficile Infection and Clostridium difficile Enzyme Immunoassay Results.

    PubMed

    Kwon, Jennie H; Reske, Kimberly A; Hink, Tiffany; Burnham, C A; Dubberke, Erik R

    2017-02-01

    The objective of this study was to evaluate the clinical characteristics and outcomes of hospitalized patients tested for Clostridium difficile and determine the correlation between pretest probability for C. difficile infection (CDI) and assay results. Patients with testing ordered for C. difficile were enrolled and assigned a high, medium, or low pretest probability of CDI based on clinical evaluation, laboratory, and imaging results. Stool was tested for C. difficile by toxin enzyme immunoassay (EIA) and toxigenic culture (TC). Chi-square analyses and the log rank test were utilized. Among the 111 patients enrolled, stool samples from nine were TC positive and four were EIA positive. Sixty-one (55%) patients had clinically significant diarrhea, 19 (17%) patients did not, and clinically significant diarrhea could not be determined for 31 (28%) patients. Seventy-two (65%) patients were assessed as having a low pretest probability of having CDI, 34 (31%) as having a medium probability, and 5 (5%) as having a high probability. None of the patients with low pretest probabilities had a positive EIA, but four were TC positive. None of the seven patients with a positive TC but a negative index EIA developed CDI within 30 days after the index test or died within 90 days after the index toxin EIA date. Pretest probability for CDI should be considered prior to ordering C. difficile testing and must be taken into account when interpreting test results. CDI is a clinical diagnosis supported by laboratory data, and the detection of toxigenic C. difficile in stool does not necessarily confirm the diagnosis of CDI. Copyright © 2017 American Society for Microbiology.

  8. Differences in capabilities of different enzyme immunoassays to detect anti-hepatitis E virus immunoglobulin G in pigs infected experimentally with hepatitis E virus genotype 3 or 4 and in pigs with unknown exposure.

    PubMed

    Zhang, H; Mohn, U; Prickett, J R; Schalk, S; Motz, M; Halbur, P G; Feagins, A R; Meng, X J; Opriessnig, T

    2011-08-01

    Hepatitis E virus (HEV), a major cause of acute viral hepatitis in humans in many developing countries, is highly prevalent in the pig population worldwide. The objective of this study was to assess the capability of three porcine prototypes of a human enzyme-linked immunosorbent assay (ELISA), an in-house ELISA and a line-immunoassay (LIA) to detect anti-HEV antibodies in pigs infected experimentally with HEV (n = 57), known to be negative for HEV infection (n = 27), or with unknown exposure to HEV infection (field samples, n = 90). All 27 samples from non-infected pigs were negative with all five assays. The earliest detection of anti-HEV antibodies occurred at 14 days post-inoculation (dpi) with four of five assays. From 42 dpi, all samples from infected pigs were detected correctly as anti-HEV positive. Kappa analysis demonstrated substantial agreement among tests (0.62-1.00) at 14 dpi and complete agreement (1.00) at 56 dpi. The overall area under the curve for all quantitative tests as determined by receiver operator characteristic analysis ranged from 0.794 to 0.831 indicating moderate accuracy. The results showed that all five assays can detect anti-HEV IgG antibodies accurately in pigs infected experimentally with HEV. In field samples, a higher prevalence of anti-HEV IgG was found in breeding herds than in growing pigs (100% versus 66.7-93.9%). These serological assays should be very useful in veterinary diagnostic labs for HEV diagnosis in swine. Copyright © 2011 Elsevier B.V. All rights reserved.

  9. Aspergillus Galactomannan Enzyme Immunoassay and Quantitative PCR for Diagnosis of Invasive Aspergillosis with Bronchoalveolar Lavage Fluid

    PubMed Central

    Musher, Benjamin; Fredricks, David; Leisenring, Wendy; Balajee, S. Arunmozhi; Smith, Caitlin; Marr, Kieren A.

    2004-01-01

    Invasive pulmonary aspergillosis (IPA) is frequent and often fatal in hematopoietic stem cell transplant patients. Diagnosis requires microbiological or histopathologic demonstration of the organism in tissues; however, cultivation of Aspergillus species from respiratory secretions has low diagnostic sensitivity. Assays to detect Aspergillus antigen or DNA in bronchoalveolar lavage (BAL) fluid could facilitate earlier diagnosis, thereby guiding optimal therapy and obviating the need for additional costly and potentially morbid diagnostic evaluation. We evaluated the performance of a galactomannan enzyme immunoassay (GM EIA; Bio-Rad) by using a range of index cutoffs to define positivity and a quantitative PCR (qPCR) assay for the detection of Aspergillus species from BAL samples of patients with proven and probable IPA (case patients; n = 49) and without IPA (control patients; n = 50). The sensitivity of the GM EIA was 61% with an index cutoff of 1.0 and 76% with an index cutoff of 0.5; the corresponding specificities were 98 and 94%, respectively. The sensitivity and specificity of qPCR assay were 67 and 100%, respectively. The sensitivity with 22 culture-negative BAL specimens from patients with IPA was 41% for GM EIA with an index cutoff of 1.0, 59% for GM EIA with an index cutoff of 0.5, and 36% for qPCR assay. GM EIA indices and DNA quantities corresponded to BAL fungal burdens, with culture-positive samples having larger amounts of antigen and DNA compared to culture-negative samples. GM EIA and qPCR assay add to the sensitivity of BAL for diagnosing IPA in high-risk patients, with excellent specificity. Adjunctive use of these tests may reduce dependence on invasive diagnostic procedures. PMID:15583275

  10. Identification, characterization, and quantitation of soluble HLA antigens in the circulation and peritoneal dialysate of renal patients.

    PubMed Central

    Gelder, F B; McDonald, J C; Landreneau, M D; McMillan, R M; Aultman, D F

    1991-01-01

    Human lymphocyte antigen (HLA) class I and class II antigens and beta 2 microglobulin (B2M) were identified in peritoneal dialysate (PD) and serum from patients with end-stage renal disease (ESRD) using monoclonal antibodies in an enzyme-linked immunoassay. The HLA class I and class II antigens each exhibited approximate molecular weights of 50,000 to 60,000 daltons by chromatography on Sepharose CL 6B. Class I antigens in serum and PD fluid were associated with B2M. Free B2M (Mr 11,500) also was detected in both sera and PD fluids. Unlike class I antigens, class II antigens were not found to have attached B2M. Class I and class II antigens eluted from 2-diethylaminoethanol ion exchange gradient columns at 0.07 mol/L (molar) phosphate buffer pH 7.2 and migrated with alpha 2-beta 1 mobility in agarose electrophoresis. Class I antigens were purified from ESRD patients' PD fluid by solid-phase immunoaffinity chromatography. Enzyme-linked immunoassay demonstrated that this purified protein was composed of a class I heavy chain and B2M. Class I allospecificity was confirmed by neutralization on known HLA typing antisera in a microcytotoxicity assay. Soluble HLA class I antigen preparations specifically inhibited blast transformation of responder lymphocytes in mixed lymphocyte culture reactions. Inhibition was dose dependent and ranged from 0% to 95%. The presence of soluble HLA antigens in body fluids may play an important part in the immunologic tolerance to self. This study demonstrates a ready source of large quantities of soluble HLA for detailed analysis. Images Fig. 1. PMID:2039290

  11. Compensatory Cellular Reactions to Nonsteroidal Anti-Inflammatory Drugs on Osteogenic Differentiation in Canine Bone Marrow-Derived Mesenchymal Stem Cells

    PubMed Central

    OH, Namgil; KIM, Sangho; HOSOYA, Kenji; OKUMURA, Masahiro

    2014-01-01

    ABSTRACT The suppressive effects of nonsteroidal anti-inflammatory drugs (NSAIDs) on the bone healing process have remained controversial, since no clinical data have clearly shown the relationship between NSAIDs and bone healing. The aim of this study was to assess the compensatory response of canine bone marrow-derived mesenchymal stem cells (BMSCs) to several classes of NSAIDs, including carprofen, meloxicam, indomethacin and robenacoxib, on osteogenic differentiation. Each of the NSAIDs (10 µM) was administered during 20 days of the osteogenic process with human recombinant IL-1β (1 ng/ml) as an inflammatory stimulator. Gene expression of osteoblast differentiation markers (alkaline phosphatase and osteocalcin), receptors of PGE2 (EP2 and EP4) and enzymes for prostaglandin (PG) E2 synthesis (COX-1, COX-2, cPGES and mPGES-1) was measured by using quantitative reverse transcription-polymerase chain reaction. Protein production levels of alkaline phosphatase, osteocalcin and PGE2 were quantified using an alkaline phosphatase activity assay, osteocalcin immunoassay and PGE2 immunoassay, respectively. Histologic analysis was performed using alkaline phosphatase staining, von Kossa staining and alizarin red staining. Alkaline phosphatase and calcium deposition were suppressed by all NSAIDs. However, osteocalcin production showed no significant suppression by NSAIDs. Gene expression levels of PGE2-related receptors and enzymes were upregulated during continuous treatment with NSAIDs, while certain channels for PGE2 synthesis were utilized differently depending on the kind of NSAIDs. These data suggest that canine BMSCs have a compensatory mechanism to restore PGE2 synthesis, which would be an intrinsic regulator to maintain differentiation of osteoblasts under NSAID treatment. PMID:24419976

  12. Development of an enzyme immunoassay for detection of antibodies against Coccidioides in dogs and other mammalian species.

    PubMed

    Chow, Nancy A; Lindsley, Mark D; McCotter, Orion Z; Kangiser, Dave; Wohrle, Ron D; Clifford, Wayne R; Yaglom, Hayley D; Adams, Laura E; Komatsu, Kenneth; Durkin, Michelle M; Baker, Rocky J; Shubitz, Lisa F; Derado, Gordana; Chiller, Tom M; Litvintseva, Anastasia P

    2017-01-01

    Coccidioides is a soil-dwelling fungus that causes coccidioidomycosis, a disease also known as Valley fever, which affects humans and a variety of animal species. Recent findings of Coccidioides in new, unexpected areas of the United States have demonstrated the need for a better understanding of its geographic distribution. Large serological studies on animals could provide important information on the geographic distribution of this pathogen. To facilitate such studies, we used protein A/G, a recombinant protein that binds IgG antibodies from a variety of mammalian species, to develop an enzyme immunoassay (EIA) that detects IgG antibodies against Coccidioides in a highly sensitive and high-throughput manner. We showed the potential of this assay to be adapted to multiple animal species by testing a collection of serum and/or plasma samples from dogs, mice, and humans with or without confirmed coccidioidomycosis. We then evaluated the performance of the assay in dogs, using sera from dogs residing in a highly endemic area, and found seropositivity rates significantly higher than those in dogs of non-endemic areas. We further evaluated the specificity of the assay in dogs infected with other fungal pathogens known to cross-react with Coccidioides. Finally, we used the assay to perform a cross-sectional serosurvey investigating dogs from Washington, a state in which infection with Coccidioides has recently been documented. In summary, we have developed a Coccidioides EIA for the detection of antibodies in canines that is more sensitive and has higher throughput than currently available methods, and by testing this assay in mice and humans, we have shown a proof of principle of its adaptability for other animal species.

  13. Development of an enzyme immunoassay for detection of antibodies against Coccidioides in dogs and other mammalian species

    PubMed Central

    Lindsley, Mark D.; McCotter, Orion Z.; Kangiser, Dave; Wohrle, Ron D.; Clifford, Wayne R.; Yaglom, Hayley D.; Adams, Laura E.; Komatsu, Kenneth; Durkin, Michelle M.; Baker, Rocky J.; Shubitz, Lisa F.; Derado, Gordana; Chiller, Tom M.; Litvintseva, Anastasia P.

    2017-01-01

    Coccidioides is a soil-dwelling fungus that causes coccidioidomycosis, a disease also known as Valley fever, which affects humans and a variety of animal species. Recent findings of Coccidioides in new, unexpected areas of the United States have demonstrated the need for a better understanding of its geographic distribution. Large serological studies on animals could provide important information on the geographic distribution of this pathogen. To facilitate such studies, we used protein A/G, a recombinant protein that binds IgG antibodies from a variety of mammalian species, to develop an enzyme immunoassay (EIA) that detects IgG antibodies against Coccidioides in a highly sensitive and high-throughput manner. We showed the potential of this assay to be adapted to multiple animal species by testing a collection of serum and/or plasma samples from dogs, mice, and humans with or without confirmed coccidioidomycosis. We then evaluated the performance of the assay in dogs, using sera from dogs residing in a highly endemic area, and found seropositivity rates significantly higher than those in dogs of non-endemic areas. We further evaluated the specificity of the assay in dogs infected with other fungal pathogens known to cross-react with Coccidioides. Finally, we used the assay to perform a cross-sectional serosurvey investigating dogs from Washington, a state in which infection with Coccidioides has recently been documented. In summary, we have developed a Coccidioides EIA for the detection of antibodies in canines that is more sensitive and has higher throughput than currently available methods, and by testing this assay in mice and humans, we have shown a proof of principle of its adaptability for other animal species. PMID:28380017

  14. Development of improved enzyme-based and lateral flow immunoassays for rapid and accurate serodiagnosis of canine brucellosis.

    PubMed

    Cortina, María E; Novak, Analía; Melli, Luciano J; Elena, Sebastián; Corbera, Natalia; Romero, Juan E; Nicola, Ana M; Ugalde, Juan E; Comerci, Diego J; Ciocchini, Andrés E

    2017-09-01

    Brucellosis is a widespread zoonotic disease caused by Brucella spp. Brucella canis is the etiological agent of canine brucellosis, a disease that can lead to sterility in bitches and dogs causing important economic losses in breeding kennels. Early and accurate diagnosis of canine brucellosis is central to control the disease and lower the risk of transmission to humans. Here, we develop and validate enzyme and lateral flow immunoassays for improved serodiagnosis of canine brucellosis using as antigen the B. canis rough lipopolysaccharide (rLPS). The method used to obtain the rLPS allowed us to produce more homogeneous batches of the antigen that facilitated the standardization of the assays. To validate the assays, 284 serum samples obtained from naturally infected dogs and healthy animals were analyzed. For the B. canis-iELISA and B. canis-LFIA the diagnostic sensitivity was of 98.6%, and the specificity 99.5% and 100%, respectively. We propose the implementation of the B. canis-LFIA as a screening test in combination with the highly accurate laboratory g-iELISA. The B. canis-LFIA is a rapid, accurate and easy to use test, characteristics that make it ideal for the serological surveillance of canine brucellosis in the field or veterinary laboratories. Finally, a blind study including 1040 serum samples obtained from urban dogs showed a prevalence higher than 5% highlighting the need of new diagnostic tools for a more effective control of the disease in dogs and therefore to reduce the risk of transmission of this zoonotic pathogen to humans. Copyright © 2017 Elsevier B.V. All rights reserved.

  15. Evaluation and reporting of enzyme immunoassay determinations of antibody to herpes simplex virus in sera and cerebrospinal fluid.

    PubMed Central

    Cremer, N E; Cossen, C K; Hanson, C V; Shell, G R

    1982-01-01

    Several methods for evaluating and reporting enzyme immunoassay (EIA) determinations of antibody to herpes simplex virus derived from one dilution of single serum samples were studied. An EIA ratio method for serological evidence of current infection from paired serum samples was also evaluated. Optical density (OD) of the reaction at a 1:100 serum dilution and estimated titers obtained by reference of the OD of the serum dilution to a standard curve were compared to the corresponding plotted EIA titer obtained by titration to endpoint. Neither the OD per se nor the estimated titer was completely predictive of the plotted titer (correlation coefficient [r] of 0.824 and 0.817, respectively), and they provided only a semiquantitative measurement of antibody concentration. For an antibody status report, however, OD would be sufficient if related to the cutoff value as an EIA index (OD of sample divided by cutoff OD for positive specimens). The OD of the EIA reaction at a single dilution (1:5) of cerebrospinal fluid, on the other hand, correlated quite well with the titer obtained by titration (r = 0.950). For serological diagnosis of current infection, the OD ratio of convalescence-phase/acute-phase sera was determined at several dilutions. A ratio of greater than or equal to 1.54 was calculated as a reliable index for a significant rise in antibody concentration and compatible with current infection. By determining the convalescent-phase/acute-phase serum ratio at two dilutions, 1:100 and 1:1,000, the EIA ratio method appeared to be a sensitive as or more sensitive than, complement fixation in diagnosing current infection. PMID:6284791

  16. Basophil activation test compared to skin prick test and fluorescence enzyme immunoassay for aeroallergen-specific Immunoglobulin-E

    PubMed Central

    2012-01-01

    Background Skin prick test (SPT) and fluorescence enzyme immunoassay (FEIA) are widely used for the diagnosis of Immunoglobulin-E (IgE)-mediated allergic disease. Basophil activation test (BAT) could obviate disadvantages of SPT and FEIA. However, it is not known whether BAT gives similar results as SPT or FEIA for aeroallergens. Objectives In this study, we compared the results of SPT, BAT and FEIA for different aeroallergens. Methods We performed BAT, SPT and FEIA in 41 atopic subjects (symptomatic and with positive SPT for at least 1 of 9 common aeroallergens) and 31 non-atopic subjects (asymptomatic and with negative SPT). Results Correlations between SPT and BAT, SPT and FEIA, and BAT and FEIA results were statistically significant but imperfect. Using SPT as the "gold standard", BAT and FEIA were similar in sensitivity. However, BAT had lower specificity than FEIA. False positive (BATposSPTneg) results were frequent in those atopic subjects who were allergic by SPT to a different allergen and rare in non-atopic subjects. The false positivity in atopic subjects was due in part to high levels of serum Total-IgE (T-IgE) levels in atopic individuals that lead to basophil activation upon staining with fluorochrome-labeled anti-IgE. Conclusion As an alternative to SPT in persons allergic to aeroallergens, BAT in its present form is useful for distinguishing atopic from non-atopic persons. However, BAT in its present form is less specific than FEIA when determining the allergen which a patient is allergic to. This is due to IgE staining-induced activation of atopic person's basophils and/or nonspecific hyperreactivity of atopic person's basophils. PMID:22264407

  17. Evaluation of two 4th generation point-of-care assays for the detection of Human Immunodeficiency Virus infection.

    PubMed

    Stafylis, Chrysovalantis; Klausner, Jeffrey D

    2017-01-01

    Fourth generation assays detect simultaneously antibodies for HIV and the p24 antigen, identifying HIV infection earlier than previous generation tests. Previous studies have shown that the Alere Determine HIV-1/2 Combo has lower than anticipated performance in detecting antibodies for HIV and the p24 antigen. Furthermore, there are currently very few studies evaluating the performance of Standard Diagnostics BIOLINE HIV Ag/Ab Combo. To evaluate the performance of the Alere Determine HIV-1/2 Combo and the Standard Diagnostics BIOLINE HIV Ag/Ab Combo in a panel of frozen serum samples. The testing panel included 133 previously frozen serum specimens from the UCLA Clinical Microbiology & Immunoserology laboratory. Reference testing included testing for HIV antibodies by a 3rd generation enzyme immunoassay followed by HIV RNA detection. Antibody negative and RNA positive sera were also tested by a laboratory 4th generation HIV Ab/Ag enzyme immunoassay. Reference testing yielded 97 positives for HIV infection and 36 negative samples. Sensitivity of the Alere test was 95% (88-98%), while the SD Bioline sensitivity was 91% (83-96%). Both assays showed 100% (90-100%) specificity. No indeterminate or invalid results were recorded. Among 13 samples with acute infection (HIV RNA positive, HIV antibody negative), 12 were found positive by the first assay and 8 by the second. The antigen component of the Alere assay detected 10 acute samples, while the SD Bioline assay detected only one. Both rapid assays showed very good overall performance in detecting HIV infection in frozen serum samples, but further improvements are required to improve the performance in acute infection.

  18. Enzyme immunoassay for measurement of murine plasminogen activator inhibitor-1, employing a specific antibody produced by the DNA vaccine method.

    PubMed

    Yamada, Takayuki; Takagi, Akira; Takeshita, Kyosuke; Yamamoto, Koji; Ito, Masafumi; Matsushita, Tadashi; Murate, Takashi; Saito, Hidehiko; Kojima, Tetsuhito

    2003-01-01

    We developed a sensitive immunoassay to determine the concentration of mouse plasminogen activator inhibitor-1. The assay was a non-competitive sandwich enzyme-linked immunosorbent assay (ELISA) based on the production of a specific polyclonal antibody against mouse plasminogen activator inhibitor type-1 (PAI-1) used both as a trapping and detecting antibody. This antibody was raised in a rabbit by direct introduction of the expression vector plasmid DNA encoding mouse PAI-1, instead of conventional immunization with the purified protein. The standard curve was constructed with a recombinant glutathione S-transferase (GST)-mouse PAI-1 fusion protein (GST-mPAI-1) and dose-response of the assay was linear for GST-mPAI-1 between 6.25 and 100 pM. In order to assess the consistency of the assay, we measured PAI-1 antigen in normal mouse pooled plasma several times. We found that the intra-assay and inter-assay coefficients of variation (CV) were 4.8% and 9.2%, respectively, indicating that the ELISA would be sufficiently repeatable and reproducible. In this assay, lipopolysaccharide (LPS)-injected mice showed substantially higher levels (22-fold) of plasma PAI-1 antigen than did control mice (12.5+/-2.4 vs. 0.58+/-0.16 nM), similar to results reported elsewhere. Taken together, the DNA vaccine method is extremely useful for preparing specific antibodies against mouse PAI-1, which can be utilized to establish the ELISA and analyze the profile of PAI-1 distributions in mice under various conditions. This approach might also be useful for immunological investigation of other coagulation factors and related proteins.

  19. Utilization of a DNA enzyme immunoassay for the detection of proviral DNA of human immunodeficiency virus type 1 by polymerase chain reaction.

    PubMed

    Zella, D; Cavicchini, A; Cattaneo, E; Cimarelli, A; Bertazzoni, U

    1995-02-01

    The detection of proviral DNA by Polymerase Chain Reaction (PCR) is regarded as an important tool in the diagnosis of HIV-1 infection, specially among adults at risk of AIDS and children born to seropositive mothers. However, application of PCR in routine testing is hampered by the need to use radioactive probes. In this study, a non-radioactive test based on a microtiter plate (DNA Enzyme ImmunoAssay, DEIA) was used for the detection of proviral sequences of HIV-1 in peripheral blood cells of different patients. The results of the PCR-DEIA assay were compared to those obtained by liquid hybridization (PCR-LH), virus isolation (VI) and Western blot (WB). The study population included 92 patients belonging to three different groups: seropositive subjects with a well-defined clinical status and WB profile; adults at risk of infection with negative or indeterminate WB; children born to seropositive mothers with still unestablished HIV-1 infection. In the seropositive subjects, both PCR-LH and PCR-DEIA confirmed infection and gave the same results as WB. In adults at risk of infection, PCR with both methods anticipated the seroconversion in one patient with indeterminate WB and confirmed the absence of infection among seronegative and other indeterminate patients. In children born to seropositive mothers, both PCR systems as well as VI permitted an early diagnosis of infection, as confirmed by the clinical follow-up. This study has shown that in subjects at risk of AIDS and in children born to seropositive mothers, the non-isotopic DEIA method presents the same sensitivity and specificity for the detection of HIV-1 infection as the radioactive procedure. The DEIA method appears to be particularly useful for the detection of PCR products in routine diagnostic analyses.

  20. Krebs cycle metabolon formation: metabolite concentration gradient enhanced compartmentation of sequential enzymes.

    PubMed

    Wu, Fei; Pelster, Lindsey N; Minteer, Shelley D

    2015-01-25

    Dynamics of metabolon formation in mitochondria was probed by studying diffusional motion of two sequential Krebs cycle enzymes in a microfluidic channel. Enhanced directional co-diffusion of both enzymes against a substrate concentration gradient was observed in the presence of intermediate generation. This reveals a metabolite directed compartmentation of metabolic pathways.

  1. Enzyme leaps fuel antichemotaxis

    PubMed Central

    Jee, Ah-Young; Dutta, Sandipan; Cho, Yoon-Kyoung

    2018-01-01

    There is mounting evidence that enzyme diffusivity is enhanced when the enzyme is catalytically active. Here, using superresolution microscopy [stimulated emission-depletion fluorescence correlation spectroscopy (STED-FCS)], we show that active enzymes migrate spontaneously in the direction of lower substrate concentration (“antichemotaxis”) by a process analogous to the run-and-tumble foraging strategy of swimming microorganisms and our theory quantifies the mechanism. The two enzymes studied, urease and acetylcholinesterase, display two families of transit times through subdiffraction-sized focus spots, a diffusive mode and a ballistic mode, and the latter transit time is close to the inverse rate of catalytic turnover. This biochemical information-processing algorithm may be useful to design synthetic self-propelled swimmers and nanoparticles relevant to active materials. Executed by molecules lacking the decision-making circuitry of microorganisms, antichemotaxis by this run-and-tumble process offers the biological function to homogenize product concentration, which could be significant in situations when the reactant concentration varies from spot to spot. PMID:29255047

  2. Nanodiamonds as pH-switchable oxidation and reduction catalysts with enzyme-like activities for immunoassay and antioxidant applications.

    PubMed

    Chen, T M; Tian, X M; Huang, L; Xiao, J; Yang, G W

    2017-10-19

    Nanodiamonds (NDs) have recently become a focus of interest from the viewpoints of both science and technology. Their intriguing properties make them suitable as biologically active substrates, in biosensor applications as well as diagnostic and therapeutic biomedical imaging probes. Here, we demonstrate that NDs, as oxidation and reduction catalysts, possess intrinsic enzyme mimetic properties of oxidase, peroxidase and catalase, and these behaviors can be switched by modulating the pH value. NDs not only catalyze the reduction of oxygen (O 2 ) and hydrogen peroxide (H 2 O 2 ) at acidic pH, but also catalyze the dismutation decomposition of H 2 O 2 to produce O 2 at alkaline pH. It was proposed that the molecular mechanism of their peroxidase-like activity is electron-transfer acceleration, the source of which is likely derived from oxygen containing functional groups on their surface. Based on the color reaction, a nanodiamond-based enzyme linked immunosorbent assay (ELISA) was established for the detection of immunoglobulin G (IgG). Surprisingly, NDs display an excellent antioxidant activity due to the protective effect against H 2 O 2 -induced cellular oxidative damage. These findings make NDs a promising enzyme mimetic candidate and expand their applications in biocatalysis, bioassays and nano-biomedicine.

  3. Theoretical limitations of quantification for noncompetitive sandwich immunoassays.

    PubMed

    Woolley, Christine F; Hayes, Mark A; Mahanti, Prasun; Douglass Gilman, S; Taylor, Tom

    2015-11-01

    Immunoassays exploit the highly selective interaction between antibodies and antigens to provide a vital method for biomolecule detection at low concentrations. Developers and practitioners of immunoassays have long known that non-specific binding often restricts immunoassay limits of quantification (LOQs). Aside from non-specific binding, most efforts by analytical chemists to reduce the LOQ for these techniques have focused on improving the signal amplification methods and minimizing the limitations of the detection system. However, with detection technology now capable of sensing single-fluorescence molecules, this approach is unlikely to lead to dramatic improvements in the future. Here, fundamental interactions based on the law of mass action are analytically connected to signal generation, replacing the four- and five-parameter fittings commercially used to approximate sigmoidal immunoassay curves and allowing quantitative consideration of non-specific binding and statistical limitations in order to understand the ultimate detection capabilities of immunoassays. The restrictions imposed on limits of quantification by instrumental noise, non-specific binding, and counting statistics are discussed based on equilibrium relations for a sandwich immunoassay. Understanding the maximal capabilities of immunoassays for each of these regimes can greatly assist in the development and evaluation of immunoassay platforms. While many studies suggest that single molecule detection is possible through immunoassay techniques, here, it is demonstrated that the fundamental limit of quantification (precision of 10 % or better) for an immunoassay is approximately 131 molecules and this limit is based on fundamental and unavoidable statistical limitations.

  4. Development and Validation of an Immunoassay for Quantification of Topoisomerase I in Solid Tumor Tissues

    PubMed Central

    Pfister, Thomas D.; Hollingshead, Melinda; Kinders, Robert J.; Zhang, Yiping; Evrard, Yvonne A.; Ji, Jiuping; Khin, Sonny A.; Borgel, Suzanne; Stotler, Howard; Carter, John; Divelbiss, Raymond; Kummar, Shivaani; Pommier, Yves; Parchment, Ralph E.; Tomaszewski, Joseph E.; Doroshow, James H.

    2012-01-01

    Background Topoisomerase I (Top1) is a proven target for cancer therapeutics. Recent data from the Fluorouracil, Oxaliplatin, CPT-11: Use and Sequencing (FOCUS) trial demonstrated that nuclear staining of Top1 correlates with chemotherapeutic efficacy. Such a correlation may help identify patients likely to respond to Top1 inhibitors and illuminate their mechanism of action. Cellular response to Top1 inhibitors is complex, but Top1 target engagement is a necessary first step in this process. This paper reports the development and validation of a quantitative immunoassay for Top1 in tumors. Methodology/Principal Findings We have developed and validated a two-site enzyme chemiluminescent immunoassay for quantifying Top1 levels in tumor biopsies. Analytical validation of the assay established the inter-day coefficient of variation at 9.3%±3.4% and a 96.5%±7.3% assay accuracy. Preclinical fit-for-purpose modeling of topotecan time- and dose-effects was performed using topotecan-responsive and -nonresponsive xenografts in athymic nude mice. Higher baseline levels of Top1 were observed in topotecan-responsive than -nonresponsive tumors. Top1 levels reached a maximal decrease 4 to 7 hours following treatment of engrafted mice with topotecan and the indenoisoquinoline NSC 724998. Conclusions/Significance Our analysis of Top1 levels in control and treated tumors supports the previously proposed mechanism of action for Top1 inhibitor efficacy, wherein higher baseline Top1 levels lead to formation of more covalent-complex-dependent double-strand break damage and, ultimately, cell death. In contrast, xenografts with lower baseline Top1 levels accumulate fewer double-stand breaks, and may be more resistant to Top1 inhibitors. Our results support further investigation into the use of Top1 levels in tumors as a potential predictive biomarker. The Top1 immunoassay described in this paper has been incorporated into a Phase I clinical trial at the National Cancer Institute to assess pharmacodynamic response in tumor biopsies and determine whether baseline Top1 levels are predictive of response to indenoisoquinoline Top1 inhibitors. PMID:23284638

  5. Biotin IgM Antibodies in Human Blood: A Previously Unknown Factor Eliciting False Results in Biotinylation-Based Immunoassays

    PubMed Central

    Chen, Tingting; Hedman, Lea; Mattila, Petri S.; Jartti, Laura; Jartti, Tuomas; Ruuskanen, Olli; Söderlund-Venermo, Maria; Hedman, Klaus

    2012-01-01

    Biotin is an essential vitamin that binds streptavidin or avidin with high affinity and specificity. As biotin is a small molecule that can be linked to proteins without affecting their biological activity, biotinylation is applied widely in biochemical assays. In our laboratory, IgM enzyme immuno assays (EIAs) of µ-capture format have been set up against many viruses, using as antigen biotinylated virus like particles (VLPs) detected by horseradish peroxidase-conjugated streptavidin. We recently encountered one serum sample reacting with the biotinylated VLP but not with the unbiotinylated one, suggesting in human sera the occurrence of biotin-reactive antibodies. In the present study, we search the general population (612 serum samples from adults and 678 from children) for IgM antibodies reactive with biotin and develop an indirect EIA for quantification of their levels and assessment of their seroprevalence. These IgM antibodies were present in 3% adults regardless of age, but were rarely found in children. The adverse effects of the biotin IgM on biotinylation-based immunoassays were assessed, including four inhouse and one commercial virus IgM EIAs, showing that biotin IgM do cause false positivities. The biotin can not bind IgM and streptavidin or avidin simultaneously, suggesting that these biotin-interactive compounds compete for the common binding site. In competitive inhibition assays, the affinities of biotin IgM antibodies ranged from 2.1×10−3 to 1.7×10−4 mol/L. This is the first report on biotin antibodies found in humans, providing new information on biotinylation-based immunoassays as well as new insights into the biomedical effects of vitamins. PMID:22879954

  6. An electrochemical immunoassay for the screening of celiac disease in saliva samples.

    PubMed

    Adornetto, Gianluca; Fabiani, Laura; Volpe, Giulia; De Stefano, Alessia; Martini, Sonia; Nenna, Raffaella; Lucantoni, Federica; Bonamico, Margherita; Tiberti, Claudio; Moscone, Danila

    2015-09-01

    A highly sensitive electrochemical immunoassay for the initial diagnosis of celiac disease (CD) in saliva samples that overcomes the problems related to its high viscosity and to the low concentration of anti-transglutaminase antigen (tTG) IgA in this medium has been developed for the first time. The system uses magnetic beads (MBs) covered with tTG, which reacts with the anti-tTG IgA antibodies present in positive saliva samples. An anti-human IgA, conjugated with alkaline phosphate (AP) enzyme, was used as the label and a strip of eight magnetized screen-printed electrodes as the electrochemical transducer. In particular, two different immunoassay approaches were optimized and blindly compared to analyze a large number of saliva samples, whose anti-tTG IgA levels were independently determined by the radioimmunoassay (RIA) method. The obtained results, expressed as Ab index, were used to perform a diagnostic test evaluation through the construction of receiver operating characteristic (ROC) curves. The approach, involving a pre-incubation between the anti-human IgA-AP and saliva samples prior to the addition of MBs-tTG, showed a cutoff of 0.022 with 95% clinical sensitivity and 96% clinical specificity. The area under the ROC curve is equal to 1, a result that classifies our test as "perfect." This study demonstrates that it is possible to perform the screening of CD with a rapid, simple, inexpensive, and sensitive method able to detect anti-tTG antibodies in saliva samples, which are easily obtained by non-invasive techniques. This aspect is of fundamental importance to screen a large number of subjects, especially in the pediatric age.

  7. Mobile Phone Ratiometric Imaging Enables Highly Sensitive Fluorescence Lateral Flow Immunoassays without External Optical Filters.

    PubMed

    Shah, Kamal G; Singh, Vidhi; Kauffman, Peter C; Abe, Koji; Yager, Paul

    2018-05-14

    Paper-based diagnostic tests based on the lateral flow immunoassay concept promise low-cost, point-of-care detection of infectious diseases, but such assays suffer from poor limits of detection. One factor that contributes to poor analytical performance is a reliance on low-contrast chromophoric optical labels such as gold nanoparticles. Previous attempts to improve the sensitivity of paper-based diagnostics include replacing chromophoric labels with enzymes, fluorophores, or phosphors at the expense of increased fluidic complexity or the need for device readers with costly optoelectronics. Several groups, including our own, have proposed mobile phones as suitable point-of-care readers due to their low cost, ease of use, and ubiquity. However, extant mobile phone fluorescence readers require costly optical filters and were typically validated with only one camera sensor module, which is inappropriate for potential point-of-care use. In response, we propose to couple low-cost ultraviolet light-emitting diodes with long Stokes-shift quantum dots to enable ratiometric mobile phone fluorescence measurements without optical filters. Ratiometric imaging with unmodified smartphone cameras improves the contrast and attenuates the impact of excitation intensity variability by 15×. Practical application was shown with a lateral flow immunoassay for influenza A with nucleoproteins spiked into simulated nasal matrix. Limits of detection of 1.5 and 2.6 fmol were attained on two mobile phones, which are comparable to a gel imager (1.9 fmol), 10× better than imaging gold nanoparticles on a scanner (18 fmol), and >2 orders of magnitude better than gold nanoparticle-labeled assays imaged with mobile phones. Use of the proposed filter-free mobile phone imaging scheme is a first step toward enabling a new generation of highly sensitive, point-of-care fluorescence assays.

  8. Development of a Microsphere-based Immunoassay for Serological Detection of African Horse Sickness Virus and Comparison with Other Diagnostic Techniques.

    PubMed

    Sánchez-Matamoros, A; Beck, C; Kukielka, D; Lecollinet, S; Blaise-Boisseau, S; Garnier, A; Rueda, P; Zientara, S; Sánchez-Vizcaíno, J M

    2016-12-01

    African horse sickness (AHS) is a viral disease that causes high morbidity and mortality rates in susceptible Equidae and therefore significant economic losses. More rapid, sensitive and specific assays are required by diagnostic laboratories to support effective surveillance programmes. A novel microsphere-based immunoassay (Luminex assay) in which beads are coated with recombinant AHS virus (AHSV) structural protein 7 (VP7) has been developed for serological detection of antibodies against VP7 of any AHSV serotype. The performance of this assay was compared with that of a commercial enzyme-linked immunosorbent assay (ELISA) and commercial lateral flow assay (LFA) on a large panel of serum samples from uninfected horses (n = 92), from a reference library of all AHSV serotypes (n = 9), on samples from horses experimentally infected with AHSV (n = 114), and on samples from West African horses suspected of having AHS (n = 85). The Luminex assay gave the same negative results as ELISA when used to test the samples from uninfected horses. Both assays detected antibodies to all nine AHSV serotypes. In contrast, the Luminex assay detected a higher rate of anti-VP7 positivity in the West African field samples than did ELISA or LFA. The Luminex assay detected anti-VP7 positivity in experimentally infected horses at 7 days post-infection, compared to 13 days for ELISA. This novel immunoassay provides a platform for developing multiplex assays, in which the presence of antibodies against multiple ASHV antigens can be detected simultaneously. This would be useful for serotyping or for differentiating infected from vaccinated animals. © 2015 Blackwell Verlag GmbH.

  9. Multiplex Immunoassay for Lyme Disease Using VlsE1-IgG and pepC10-IgM Antibodies: Improving Test Performance through Bioinformatics ▿

    PubMed Central

    Porwancher, Richard B.; Hagerty, C. Greg; Fan, Jianqing; Landsberg, Lisa; Johnson, Barbara J. B.; Kopnitsky, Mark; Steere, Allen C.; Kulas, Karen; Wong, Susan J.

    2011-01-01

    The Centers for Disease Control and Prevention currently recommends a 2-tier serologic approach to Lyme disease laboratory diagnosis, comprised of an initial serum enzyme immunoassay (EIA) for antibody to Borrelia burgdorferi followed by supplementary IgG and IgM Western blotting of EIA-positive or -equivocal samples. Western blot accuracy is limited by subjective interpretation of weakly positive bands, false-positive IgM immunoblots, and low sensitivity for detection of early disease. We developed an objective alternative second-tier immunoassay using a multiplex microsphere system that measures VlsE1-IgG and pepC10-IgM antibodies simultaneously in the same sample. Our study population comprised 79 patients with early acute Lyme disease, 82 patients with early-convalescent-phase disease, 47 patients with stage II and III disease, 34 patients post-antibiotic treatment, and 794 controls. A bioinformatic technique called partial receiver-operator characteristic (ROC) regression was used to combine individual antibody levels into a single diagnostic score with a single cutoff; this technique enhances test performance when a high specificity is required (e.g., ≥95%). Compared to Western blotting, the multiplex assay was equally specific (95.6%) but 20.7% more sensitive for early-convalescent-phase disease (89.0% versus 68.3%, respectively; 95% confidence interval [95% CI] for difference, 12.1% to 30.9%) and 12.5% more sensitive overall (75.0% versus 62.5%, respectively; 95% CI for difference, 8.1% to 17.1%). As a second-tier test, a multiplex assay for VlsE1-IgG and pepC10-IgM antibodies performed as well as or better than Western blotting for Lyme disease diagnosis. Prospective validation studies appear to be warranted. PMID:21367982

  10. Evaluation of a Newly Developed Lateral Flow Immunoassay for the Diagnosis of Cryptococcosis

    PubMed Central

    Lindsley, Mark D.; Mekha, Nanthawan; Baggett, Henry C.; Surinthong, Yupha; Autthateinchai, Rinrapas; Sawatwong, Pongpun; Harris, Julie R.; Park, Benjamin J.; Chiller, Tom; Poonwan, Natteewan

    2011-01-01

    Background. Cryptococcosis is a common opportunistic infection of human immunodeficiency virus (HIV)–infected individuals mostly occurring in resource-limited countries. This study compares the performance of a recently developed lateral flow immunoassay (LFA) to blood culture and enzyme immunoassay (EIA) for the diagnosis of cryptococcosis. Methods. Archived sera from 704 HIV-infected patients hospitalized for acute respiratory illness in Thailand were tested for cryptococcal antigenemia using EIA. All EIA-positive and a subset of EIA-negative sera were tested by LFA, with results recorded after 5 and 15 minutes incubation. Urine from patients with LFA- and EIA-positive sera was tested by LFA. Antigen results from patients with positive cryptococcal blood cultures were compared. Results. Of 704 sera, 92 (13%) were positive by EIA; among the 91 EIA-positive sera tested by LFA, 82 (90%) and 87 (96%) were LFA positive when read after 5 and 15 minutes, respectively. Kappa agreement of EIA and LFA for sera was 0.923 after 5 minutes and 0.959 after 15 minutes, respectively. Two of 373 EIA-negative sera were LFA positive at both time points. Of 74 urine specimens from EIA-positive patients, 52 (70.3%) were LFA positive. EIA was positive in 16 of 17 sera from blood culture–positive patients (94% sensitivity), and all sera were positive by LFA (100% sensitivity). Conclusions. A high level of agreement was shown between LFA and EIA testing of serum. The LFA is a rapid, easy-to-perform assay that does not require refrigeration, demonstrating its potential usefulness as a point-of-care assay for diagnosis of cryptococcosis in resource-limited countries. PMID:21810743

  11. A novel acute HIV infection staging system based on 4th generation immunoassay.

    PubMed

    Ananworanich, Jintanat; Fletcher, James L K; Pinyakorn, Suteeraporn; van Griensven, Frits; Vandergeeten, Claire; Schuetz, Alexandra; Pankam, Tippawan; Trichavaroj, Rapee; Akapirat, Siriwat; Chomchey, Nitiya; Phanuphak, Praphan; Chomont, Nicolas; Michael, Nelson L; Kim, Jerome H; de Souza, Mark

    2013-05-29

    Fourth generation (4thG) immunoassay (IA) is becoming the standard HIV screening method but was not available when the Fiebig acute HIV infection (AHI) staging system was proposed. Here we evaluated AHI staging based on a 4thG IA (4thG staging). Screening for AHI was performed in real-time by pooled nucleic acid testing (NAT, n=48,828 samples) and sequential enzyme immunoassay (EIA, n=3,939 samples) identifying 63 subjects with non-reactive 2nd generation EIA (Fiebig stages I (n=25), II (n=7), III (n=29), IV (n=2)). The majority of samples tested (n=53) were subtype CRF_01AE (77%). NAT+ subjects were re-staged into three 4thG stages: stage 1 (n=20; 4th gen EIA-, 3rd gen EIA-), stage 2 (n=12; 4th gen EIA+, 3rd gen EIA-), stage 3 (n=31; 4th gen EIA+, 3rd gen EIA+, Western blot-/indeterminate). 4thG staging distinguishes groups of AHI subjects by time since presumed HIV exposure, pattern of CD8+ T, B and natural killer cell absolute numbers, and HIV RNA and DNA levels. This staging system further stratified Fiebig I subjects: 18 subjects in 4thG stage 1 had lower HIV RNA and DNA levels than 7 subjects in 4thG stage 2. Using 4th generation IA as part of AHI staging distinguishes groups of patients by time since exposure to HIV, lymphocyte numbers and HIV viral burden. It identifies two groups of Fiebig stage I subjects who display different levels of HIV RNA and DNA, which may have implication for HIV cure. 4th generation IA should be incorporated into AHI staging systems.

  12. Sensitising effects of genetically modified enzymes used in flavour, fragrance, detergence and pharmaceutical production: cross-sectional study.

    PubMed

    Budnik, Lygia T; Scheer, Edwin; Burge, P Sherwood; Baur, Xaver

    2017-01-01

    The use of genetically engineered enzymes in the synthesis of flavourings, fragrances and other applications has increased tremendously. There is, however, a paucity of data on sensitisation and/or allergy to the finished products. We aimed to review the use of genetically modified enzymes and the enormous challenges in human biomonitoring studies with suitable assays of specific IgE to a variety of modified enzyme proteins in occupational settings and measure specific IgE to modified enzymes in exposed workers. Specific IgE antibodies against workplace-specific individual enzymes were measured by the specific fluorescence enzyme-labelled immunoassay in 813 exposed workers seen in cross-sectional surveys. Twenty-three per cent of all exposed workers showed type I sensitisation with IgE antibodies directed against respective workplace-specific enzymes. The highest sensitisation frequencies observed were for workers exposed enzymes derived from α-amylase (44%), followed by stainzyme (41%), pancreatinin (35%), savinase (31%), papain (31%), ovozyme (28%), phytase (16%), trypsin (15%) and lipase (4%). The highest individual antibody levels (up to 110 kU/L) were detected in workers exposed to phytase, xylanase and glucanase. In a subgroup comprising 134 workers, detailed clinical diagnostics confirmed work-related symptoms. There was a strong correlation (r=0.75, p<0.0001) between the symptoms and antibody levels. Workers with work-related respiratory symptoms showed a higher prevalence for the presence of specific IgE antibodies against workplace-specific enzymes than asymptomatic exposed workers (likelihood ratio 2.32, sensitivity 0.92, specificity 0.6). Our data confirm the previous findings showing that genetically engineered enzymes are potent allergens eliciting immediate-type sensitisation. Owing to lack of commercial diagnostic tests, few of those exposed receive regular surveillance including biomonitoring with relevant specific IgE assays. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  13. Central nervous system dysfunction associated with Rocky Mountain spotted fever infection in five dogs.

    PubMed

    Mikszewski, Jessica S; Vite, Charles H

    2005-01-01

    Five dogs from the northeastern United States were presented with clinical signs of neurological disease associated with Rocky Mountain spotted fever (RMSF) infection. Four of the five dogs had vestibular system dysfunction. Other neurological signs included paresis, tremors, and changes in mentation. All of the dogs had an elevated indirect fluorescent antibody titer or a positive semiquantitative enzyme screening immunoassay titer for Rickettsia rickettsii at the time of presentation. Although a higher mortality rate has been reported for dogs with neurological symptoms and RMSF infection, all of the dogs in this study improved with appropriate medical therapy and supportive care.

  14. Diagnosis of feline leukaemia virus infection by semi-quantitative real-time polymerase chain reaction.

    PubMed

    Pinches, Mark D G; Helps, Christopher R; Gruffydd-Jones, Tim J; Egan, Kathy; Jarrett, Oswald; Tasker, Séverine

    2007-02-01

    In this paper the design and use of a semi-quantitative real-time polymerase chain reaction assay (RT-PCR) for feline leukaemia virus (FeLV) provirus is described. Its performance is evaluated against established methods of FeLV diagnosis, including virus isolation and enzyme-linked immunoassay (ELISA) in a population of naturally infected cats. The RT-PCR assay is found to have both a high sensitivity (0.92) and specificity (0.99) when examined by expectation maximisation methods and is also able to detect a large number of cats with low FeLV proviral loads that were negative by other conventional test methods.

  15. Hepatitis C: a possible etiology for cryoglobulinaemia type II.

    PubMed Central

    Pechère-Bertschi, A; Perrin, L; de Saussure, P; Widmann, J J; Giostra, E; Schifferli, J A

    1992-01-01

    Out of 15 successive patients with mixed essential cryoglobulinaemia type II (monoclonal IgM kappa/IgG), 13 had serological evidence for hepatitis C infection as shown by specific enzyme immunoassays and immunoblot. RNA was purified from the serum of seven patients and hepatitis C sequences were identified in five following reverse transcription and DNA amplification. The liver histology showed chronic active hepatitis with or without cirrhosis in the 12 patients with hepatitis C who had a liver biopsy. The two patients without serological evidence of hepatitis C suffered from haematological malignancies. Hepatitis C may be a major etiological agent of cryoglobulinaemia type II. PMID:1381302

  16. Development of a Serological Test for Haemophilus ducreyi for Seroprevalence Studies

    PubMed Central

    Elkins, Christopher; Yi, Kyungcheol; Olsen, Bonnie; Thomas, Christopher; Thomas, Kevin; Morse, Stephen

    2000-01-01

    We developed a new enzyme immunoassay (rpEIA) for use in determining the seroprevalence of chancroid. Three highly conserved outer membrane proteins from Haemophilus ducreyi strain 35000 were cloned, overexpressed, and purified from Escherichia coli for use as antigens in the rpEIA. Serum specimens from patients with and without chancroid were assayed to determine optimum sensitivity and specificity and to establish cutoff values. On the basis of these data, rpEIA was found to be both sensitive and specific when used to test a variety of serum specimens from patients with genital ulcers and urethritis and from healthy blood donors. PMID:10747137

  17. Seroprevalence of Trypanosoma evansi in dromedaries (Camelus dromedarius) from the Canary Islands (Spain) using an antibody Ab-ELISA.

    PubMed

    Molina, J M; Ruiz, A; Juste, M C; Corbera, J A; Amador, R; Gutiérrez, C

    1999-10-19

    After the description in Grand Canary Island of a case of dromedary trypanosomosis caused by Trypanosoma evansi in 1998, an indirect enzyme immunoassay for the detection of specific anti-T. evansi IgG (Ab-ELISA) was used to assess the seroprevalence of this disease on the Canary Islands. Seroprevalence was 9.0% in the four studied islands (Gran Canaria, Tenerife, Lanzarote and Fuerteventura), varying from 10.0 to 7.5% by island (not significantly different). Prevalence using Ab-ELISA was higher than that observed when a parasitological method (microscopic observation of blood smears) was used (1.3%).

  18. Peptide radioimmunoassays in clinical medicine.

    PubMed

    Geokas, M C; Yalow, R S; Straus, E W; Gold, E M

    1982-09-01

    The radioimmunoassay technique, first developed for the determination of hormones, has been applied to many substances of biologic interest by clinical and research laboratories around the world. It has had an enormous effect in medicine and biology as a diagnostic tool, a guide to therapy, and a probe for the fine structure of biologic systems. For instance, the assays of insulin, gastrin, secretin, prolactin, and certain tissue-specific enzymes have been invaluable in patient care. Further refinements of current methods, as well as the emergence of new immunoassay techniques, are expected to enhance precision, specificity, reliability, and convenience of the radioimmunoassay in both clinical and research laboratories.

  19. Quantitative determination of limonin in citrus juices by HPLC using computerized solvent optimization.

    PubMed

    Shaw, P E; Wilson, C W

    1988-09-01

    The commercially available computer program, Drylab, for optimization of separations by high-performance liquid chromatography (HPLC) using binary solvent mixtures is used to improve an HPLC method for separation of the bitter principle, limonin, in grapefruit and navel orange juices. Best conditions for separation of limonin in a reasonable time are 30 to 32% acetonitrile in water at 0.9 mL/min using a 5-micron C18 column 10 cm long. These conditions are used to analyze grapefruit and navel orange juice samples, and these HPLC results are compared with values determined by enzyme immunoassay or thin-layer chromatography (TLC) on the same samples.

  20. AN ENVIRONMENTAL TECHNOLOGY VERIFICATION (ETV) TESTING OF THREE IMMUNOASSAY TEST KITS FOR ANTHRAX, BOTULINUM TOXIN AND RICIN

    EPA Science Inventory

    Immunoassay test kits are based on immunoassay methods, where specific antibodies are used to detect and measure the contaminants of interest. Immunoassay test kits rely on the reaction of a contaminant or antigen with a selective antibody to give a product that can be measures....

  1. Highly efficient enzyme encapsulation in a protein nanocage: towards enzyme catalysis in a cellular nanocompartment mimic

    NASA Astrophysics Data System (ADS)

    Schoonen, Lise; Nolte, Roeland J. M.; van Hest, Jan C. M.

    2016-07-01

    The study of enzyme behavior in small nanocompartments is crucial for the understanding of biocatalytic processes in the cellular environment. We have developed an enzymatic conjugation strategy to attach a model enzyme to the interior of a cowpea chlorotic mottle virus capsid. It is shown that with this methodology high encapsulation efficiencies can be achieved. Additionally, we demonstrate that the encapsulation does not affect the enzyme performance in terms of a decreased activity or a hampered substrate diffusion. Finally, it is shown that the encapsulated enzymes are protected against proteases. We believe that our strategy can be used to study enzyme kinetics in an environment that approaches physiological conditions.The study of enzyme behavior in small nanocompartments is crucial for the understanding of biocatalytic processes in the cellular environment. We have developed an enzymatic conjugation strategy to attach a model enzyme to the interior of a cowpea chlorotic mottle virus capsid. It is shown that with this methodology high encapsulation efficiencies can be achieved. Additionally, we demonstrate that the encapsulation does not affect the enzyme performance in terms of a decreased activity or a hampered substrate diffusion. Finally, it is shown that the encapsulated enzymes are protected against proteases. We believe that our strategy can be used to study enzyme kinetics in an environment that approaches physiological conditions. Electronic supplementary information (ESI) available: Experimental procedures for the cloning, expression, and purification of all proteins, as well as supplementary figures and calculations. See DOI: 10.1039/c6nr04181g

  2. Rapid Bead-Based Antimicrobial Susceptibility Testing by Optical Diffusometry

    PubMed Central

    Chung, Chih-Yao; Wang, Jhih-Cheng; Chuang, Han-Sheng

    2016-01-01

    This study combined optical diffusometry and bead-based immunoassays to develop a novel technique for quantifying the growth of specific microorganisms and achieving rapid AST. Diffusivity rises when live bacteria attach to particles, resulting in additional energy from motile microorganisms. However, when UV-sterilized (dead) bacteria attach to particles, diffusivity declines. The experimental data are consistent with the theoretical model predicted according to the equivalent volume diameter. Using this diffusometric platform, the susceptibility of Pseudomonas aeruginosa to the antibiotic gentamicin was tested. The result suggests that the proliferation of bacteria is effectively controlled by gentamicin. This study demonstrated a sensitive (one bacterium on single particles) and time-saving (within 2 h) platform with a small sample volume (~0.5 μL) and a low initial bacteria count (50 CFU per droplet ~ 105 CFU/mL) for quantifying the growth of microorganisms depending on Brownian motion. The technique can be applied further to other bacterial strains and increase the success of treatments against infectious diseases in the near future. PMID:26863001

  3. Application and evaluation of enzyme-linked immunosorbent assay and immunoblotting for detection of antibodies to Treponema hyodysenteriae in swine.

    PubMed Central

    Smith, S. C.; Barrett, L. M.; Muir, T.; Christopher, W. L.; Coloe, P. J.

    1991-01-01

    An enzyme-linked immunoassay (ELISA) has been developed to detect serum Immunoglobulin antibodies G and M to Treponema hyodysenteriae in vaccinated, experimentally infected and naturally infected swine. Naturally infected swine gave ELISA titres that were similar to experimentally infected swine, but were significantly less than the titres of vaccinated swine. When serum from naturally infected swine was used to probe nitrocellulose blots of sodium dodecyl sulphate-polyacrylamide gel electrophoresed whole cell proteins of T. hyodysenteriae, the immunoblotting patterns showed IgG antibodies were produced against many T. hyodysenteriae protein antigens and against lipopolysaccharide (LPS). The IgG antibodies directed against LPS were serotype-specific for that LPS and could be used to identify the serotype involved in the T. hyodysenteriae infection in that herd. IgM immunoblots also reacted with the many protein antigens but were less specific for LPS antigen, with a substantial degree of cross-reaction between the LPS of all serotypes. The data demonstrate that a microplate enzyme-linked immunosorbent assay, coupled with immunoblotting, is a very specific and sensitive test for detection of antibody to Treponema hyodysenteriae in swine. Images Fig. 3 Fig. 4 PMID:1936151

  4. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Riedel, Clement; Gabizon, Ronen; Wilson, Christian A. M.

    Recent studies have shown that the diffusivity of enzymes increases in a substrate-dependent manner during catalysis. Although this observation has been reported and characterized for several different systems, the precise origin of this phenomenon is unknown. Calorimetric methods are often used to determine enthalpies from enzyme-catalysed reactions and can therefore provide important insight into their reaction mechanisms. The ensemble averages involved in traditional bulk calorimetry cannot probe the transient effects that the energy exchanged in a reaction may have on the catalyst. Here we obtain single-molecule fluorescence correlation spectroscopy data and analyse them within the framework of a stochastic theorymore » to demonstrate a mechanistic link between the enhanced diffusion of a single enzyme molecule and the heat released in the reaction. We propose that the heat released during catalysis generates an asymmetric pressure wave that results in a differential stress at the protein-solvent interface that transiently displaces the centre-of-mass of the enzyme (chemoacoustic effect). We find this novel perspective on how enzymes respond to the energy released during catalysis suggests a possible effect of the heat of reaction on the structural integrity and internal degrees of freedom of the enzyme.« less

  5. Inhibition of substance P signaling aggravates the bone loss in ovariectomy-induced osteoporosis.

    PubMed

    Zheng, Xin-Feng; Zhao, En-Dian; He, Ji-Ye; Zhang, Yue-Hui; Jiang, Sheng-Dan; Jiang, Lei-Sheng

    2016-11-01

    Substance P signaling regulates the functions of both osteoblast and osteoclast. Available reports on the effects of substance P on bone mass are contradictory. The objective of this study was to determine the change of substance P expression in the osteoporotic bone of OVX mice. The effects of substance P signaling blockade by using its specific receptor antagonist L-703606 on bone remodeling in sham-operated mice and OVX mice were also investigated. Forty-eight nine-week-old female C57BL/6J mice were evenly distributed into three groups with sham surgery, OVX or OVX with estrogen replacement. Substance P expression in the bones of each group of mice was evaluated by immunohistochemistry and enzyme immunoassay. Another thirty-two nine-week-old female C57BL/6J mice were divided into a SHAM group (sham surgery followed by vehicle treatment with DMSO), a SHAM + L group (sham surgery followed by 15 mg/kg/d L-703606 repeated intraperitoneal injections), an OVX group (ovariectomy with the same vehicle treatment) and an OVX + L group (ovariectomy with the same L-703606 injections), with 8 mice in each group. Treatment started 3 weeks after surgery and last for 3 weeks. A 2 × 2 factorial experimental design was used to detect the effects of substance P signaling blockade on bone remodeling in sham-operated mice and OVX mice. Techniques including micro-computed tomography, biomechanical testing, histomorphometric analysis, enzyme immunoassay, and real-time PCR were employed. Immunohistochemistry and enzyme immunoassay revealed that substance P expression significantly decreased in the bones of OVX mice both at 3 weeks and 6 weeks after surgery. Micro-CT tomography demonstrated that application of L-703606 led to bone loss in sham-operated mice, and aggravated the micro-structural deterioration of bones in OVX mice. This was shown by reduced BV/TV (Mean bone volume fraction), Tb.N (Mean trabecular number) and Tb.Th (Mean trabecular thickness), and increased Tb.Sp (Mean trabecular separation). Biomechanical analysis demonstrated that blockade of substance P signaling reduced the maximum stress and maximum load of L3 vertebrae and tibiae. Inhibited recruitment of bone mesenchymal stem cells (BMSCs) to bone remodeling sites, which was evidenced by increased number of osteoclasts, decreased number of osteoblasts and increased osteoid volume in the secondary spongiosa, was observed in the mice treated with L-703606. A significant decrease of OPG/RANKL ratio was also found in the bones of mice treated with L-703606. Body weight, uterine weight and serum estradiol level were not significantly different between the mice treated with L-703606 and those treated with vehicle. The results demonstrated that blocking substance P signaling led to bone loss in sham-operated mice, and exacerbated the bone loss in OVX mice. Substance P signaling had an important role in the maintenance of bone mass. Copyright © 2016 Elsevier Ltd. All rights reserved.

  6. Tyrosine hydroxylase (TH), its cofactor tetrahydrobiopterin (BH4), other catecholamine-related enzymes, and their human genes in relation to the drug and gene therapies of Parkinson's disease (PD): historical overview and future prospects.

    PubMed

    Nagatsu, Toshiharu; Nagatsu, Ikuko

    2016-11-01

    Tyrosine hydroxylase (TH), which was discovered at the National Institutes of Health (NIH) in 1964, is a tetrahydrobiopterin (BH4)-requiring monooxygenase that catalyzes the first and rate-limiting step in the biosynthesis of catecholamines (CAs), such as dopamine, noradrenaline, and adrenaline. Since deficiencies of dopamine and noradrenaline in the brain stem, caused by neurodegeneration of dopamine and noradrenaline neurons, are mainly related to non-motor and motor symptoms of Parkinson's disease (PD), we have studied human CA-synthesizing enzymes [TH; BH4-related enzymes, especially GTP-cyclohydrolase I (GCH1); aromatic L-amino acid decarboxylase (AADC); dopamine β-hydroxylase (DBH); and phenylethanolamine N-methyltransferase (PNMT)] and their genes in relation to PD in postmortem brains from PD patients, patients with CA-related genetic diseases, mice with genetically engineered CA neurons, and animal models of PD. We purified all human CA-synthesizing enzymes, produced their antibodies for immunohistochemistry and immunoassay, and cloned all human genes, especially the human TH gene and the human gene for GCH1, which synthesizes BH4 as a cofactor of TH. This review discusses the historical overview of TH, BH4-, and other CA-related enzymes and their genes in relation to the pathophysiology of PD, the development of drugs, such as L-DOPA, and future prospects for drug and gene therapy for PD, especially the potential of induced pluripotent stem (iPS) cells.

  7. Thermophysical properties of enzyme clarified Lime (Citrus aurantifolia L) juice at different moisture contents.

    PubMed

    Manjunatha, S S; Raju, P S; Bawa, A S

    2014-11-01

    Thermophysical properties of enzyme clarified lime (Citrus aurantifolia L.) juice were evaluated at different moisture contents ranging from 30.37 % to 89.30 % (wet basis) corresponding to a water activity range of 0.835 to 0.979. The thermophysical properties evaluated were density, Newtonian viscosity, thermal conductivity, specific heat and thermal diffusivity. The investigation showed that density and Newtonian viscosity of enzyme clarified lime juice decreased significantly (p < 0.05) with increase in moisture content and water activity, whereas thermal conductivity and specific heat increased significantly (p < 0.05) with increase in moisture content and water activity and the thermal diffusivity increased marginally. Empirical mathematical models were established relating to thermophysical properties of enzyme clarified lime juice with moisture content/water activity employing regression analysis by the method of least square approximation. Results indicated the existence of strong correlation between thermophysical properties and moisture content/water activity of enzyme clarified lime juice, a significant (p < 0.0001) negative correlation between physical and thermal properties was observed.

  8. Effects of the fluid flows on enzymatic chemical oscillations

    NASA Astrophysics Data System (ADS)

    Shklyaev, Oleg; Yashin, Victor; Balazs, Anna

    2017-11-01

    Chemical oscillations are ubiquitous in nature and have a variety of promising applications. Usually, oscillating chemical systems are analyzed within the context of a reaction-diffusion framework. Here, we examine how fluid flows carrying the reactants can be utilized to modulate the negative feedback loops and time delays that promote chemical oscillations. We consider a model where a chemical reaction network involves two species, X and Y, which undergo transformations catalyzed by respective enzymes immobilized at the bottom wall of a fluid-filled microchamber. The reactions with the enzymes provide a negative feedback in the chemically oscillating system. In particular, the first enzyme, localized on the first patch, promotes production of chemical X, while the second enzyme, immobilized on the second patch, promotes production of chemical Y, which inhibits the production of chemical X. The separation distance between the enzyme-coated patches sets the time delay required for the transportation of X and Y. The chemical transport is significantly enhanced if convective fluxes accompany the diffusive ones. Therefore, the parameter region where oscillations are present is modified. The findings provide guidance to designing micro-scale chemical reactors with improved functionalities.

  9. Cytokines released from blood monocytes and expressed in mucocutaneous lesions of patients with paracoccidioidomycosis evaluated before and during trimethoprim-sulfamethoxazole treatment.

    PubMed

    Parise-Fortes, M R; Marques, S A; Soares, A M V C; Kurokawa, C S; Marques, M E A; Peracoli, M T S

    2006-04-01

    Mucocutaneous lesions in paracoccidioidomycosis are granulomatous and result from tissue responses to Paracoccidioides brasiliensis, the aetiological agent. In this study we investigate the expression of tumour necrosis factor (TNF)-alpha, interleukin (IL)-10 and transforming growth factor (TGF)-beta1 by immunohistochemistry in skin and mucosa lesions from patients with the chronic form of paracoccidioidomycosis, evaluated before and at day 20 of trimethoprim-sulfamethoxazole treatment. Cytokine production by peripheral blood monocytes was also studied by enzyme immunoassay. Intense immunostaining for TNF-alpha was detected in mononuclear cells that infiltrated granulomas in all skin and mucosa lesions before treatment simultaneously with low IL-10 granular deposits in these cells. At day 20 of treatment, there was reduced TNF-alpha and IL-10 deposition. Immunoreactive TGF-beta1 was observed diffusely in the dermis and generally in the cytoplasm of macrophages and giant cells, before treatment, and as increased TGF-beta1 deposits in the fibrosis area at day 20 of treatment. Peripheral blood monocytes from patients with paracoccidioidomycosis, evaluated before treatment, produced high endogenous levels of TNF-alpha, TGF-beta1 and IL-10 in relation to healthy controls. Lipopolysaccharide-stimulated monocytes from patients secreted lower levels of TNF-alpha in both periods of evaluation while no impairment in capacity of IL-10 and TGF-beta production was observed. Trimethoprim-sulfamethoxazole therapy was effective in decreasing fungal load in the lesions, allowing patient immune response to control the infection leading to the healing of the lesions.

  10. A bio-image sensor for simultaneous detection of multi-neurotransmitters.

    PubMed

    Lee, You-Na; Okumura, Koichi; Horio, Tomoko; Iwata, Tatsuya; Takahashi, Kazuhiro; Hattori, Toshiaki; Sawada, Kazuaki

    2018-03-01

    We report here a new bio-image sensor for simultaneous detection of spatial and temporal distribution of multi-neurotransmitters. It consists of multiple enzyme-immobilized membranes on a 128 × 128 pixel array with read-out circuit. Apyrase and acetylcholinesterase (AChE), as selective elements, are used to recognize adenosine 5'-triphosphate (ATP) and acetylcholine (ACh), respectively. To enhance the spatial resolution, hydrogen ion (H + ) diffusion barrier layers are deposited on top of the bio-image sensor and demonstrated their prevention capability. The results are used to design the space among enzyme-immobilized pixels and the null H + sensor to minimize the undesired signal overlap by H + diffusion. Using this bio-image sensor, we can obtain H + diffusion-independent imaging of concentration gradients of ATP and ACh in real-time. The sensing characteristics, such as sensitivity and detection of limit, are determined experimentally. With the proposed bio-image sensor the possibility exists for customizable monitoring of the activities of various neurochemicals by using different kinds of proton-consuming or generating enzymes. Copyright © 2017 Elsevier B.V. All rights reserved.

  11. Micellar Polymer Encapsulation of Enzymes.

    PubMed

    Besic, Sabina; Minteer, Shelley D

    2017-01-01

    Although enzymes are highly efficient and selective catalysts, there have been problems incorporating them into fuel cells. Early enzyme-based fuel cells contained enzymes in solution rather than immobilized on the electrode surface. One problem utilizing an enzyme in solution is an issue of transport associated with long diffusion lengths between the site of bioelectrocatalysis and the electrode. This issue drastically decreases the theoretical overall power output due to the poor electron conductivity. On the other hand, enzymes immobilized at the electrode surface have eliminated the issue of poor electron conduction due to close proximity of electron transfer between electrode and the biocatalyst. Another problem is inefficient and short term stability of catalytic activity within the enzyme that is suspended in free flowing solution. Enzymes in solutions are only stable for hours to days, whereas immobilized enzymes can be stable for weeks to months and now even years. Over the last decade, there has been substantial research on immobilizing enzymes at electrode surfaces for biofuel cell and sensor applications. The most commonly used techniques are sandwich or wired. Sandwich techniques are powerful and successful for enzyme immobilization; however, the enzymes optimal activity is not retained due to the physical distress applied by the polymer limiting its applications as well as the non-uniform distribution of the enzyme and the diffusion of analyte through the polymer is slowed significantly. Wired techniques have shown to extend the lifetime of an enzyme at the electrode surface; however, this technique is very hard to master due to specific covalent bonding of enzyme and polymer which changes the three-dimensional configuration of enzyme and with that decreases the optimal catalytic activity. This chapter details encapsulation techniques where an enzyme will be immobilized within the pores/pockets of the hydrophobically modified micellar polymers such as Nafion ® and chitosan. This strategy has been shown to safely immobilize enzymes at electrode surfaces with storage and continuous operation lifetime of more than 2 years.

  12. Effects of grain species and cultivar, thermal processing, and enzymatic hydrolysis on gluten quantitation.

    PubMed

    Pahlavan, Autusa; Sharma, Girdhari M; Pereira, Marion; Williams, Kristina M

    2016-10-01

    Gluten from wheat, rye, and barley can trigger IgE-mediated allergy or Celiac disease in sensitive individuals. Gluten-free labeled foods are available as a safe alternative. Immunoassays such as the enzyme-linked immunosorbent assay (ELISA) are commonly used to quantify gluten in foods. However, various non-assay related factors can affect gluten quantitation. The effect of gluten-containing grain cultivars, thermal processing, and enzymatic hydrolysis on gluten quantitation by various ELISA kits was evaluated. The ELISA kits exhibited variations in gluten quantitation depending on the gluten-containing grain and their cultivars. Acceptable gluten recoveries were obtained in 200mg/kg wheat, rye, and barley-spiked corn flour thermally processed at various conditions. However, depending on the enzyme, gluten grain source, and ELISA kit used, measured gluten content was significantly reduced in corn flour spiked with 200mg/kg hydrolyzed wheat, rye, and barley flour. Thus, the gluten grain source and processing conditions should be considered for accurate gluten analysis. Published by Elsevier Ltd.

  13. [Rheumatoid factor activity as a disturbing factor in the serological diagnosis of specific IgM antibodies].

    PubMed

    Lindenschmidt, E G

    1984-04-01

    Rheumatoid factors (RF) are autoantibodies mainly directed against autologous IgG. They belong at most to the IgM class antibodies. It is demonstrated at groups with unsolved hepatitis B, rubella, syphilis and toxoplasmose infection that RF do occur not rarely at these patients even without rheumatoid arthritis. This is probably due to stimulation by antigen-IgG-complexes. During serologic detection of specific IgM antibodies they present an antigen independent mu-specificity. So the test for specific IgM might even loose its diagnostic and possibly therapy indicating value. It is shown how the disturbance by RF can be calculated after adsorption with aggregated IgG. Also RF can be titrated by an enzyme immunoassay (ELISA). With IgG coated latex particles RF can be eliminated prior to the IgM-test. Solid phase techniques which are applied with enzyme-coupled antigen instead of marked anti-IgM cannot be disturbed by RF significantly.

  14. Development of an indirect enzyme linked immunoassay for abscisic acid. [Pisum sativum

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ross, G.S.; Elder, P.A.; McWha, J.A.

    1987-09-01

    AN INDIRECT METHOD OF ENZYME-LINKED-IMMUNOSORBENT-ASSAY (ELISA) IS REPORTED FOR ABSCISIC ACID (ABA), UTILIZING A THYROGLOBULIN-ABA CONJUGATE FOR COATING WELLS. THE ASSAY CAN USE COMMERCIALLY AVAILABLE MONOCLONAL ANTIBODIES, IS SENSITIVE TO AS LITTLE AS 20 PICOGRAMS ABA PER WELL, AND IS MUCH MORE CONSERVATIVE OF ANTIBODY THAN DIRECT METHODS. THE MOST DILUTE ABA STANDARDS DID NOT RETAIN THEIR ANTIGENICITY DURING STORAGE, SO ABA STANDARD SETS WERE DILUTED IMMEDIATELY PRIOR TO USE. THE INDIRECT ELISA WAS USED SUCCESSFULLY TO ESTIMATE ABA CONCENTRATIONS IN DEVELOPING COTYLEDONS OF PISUM SATIVUM L., AFTER ONLY LITTLE PRELIMINARY PURIFICATION. IT WAS VALIDATED FOR THIS TISSUE THROUGH THEmore » USE OF GAS CHROMATOGRAPHY-ELECTRON CAPTURE DETECTION (GC-EC), AND CAPILLARY GC-SELECTED ION MONITORING (GC-MS-SIM) USING LABELLED ABA AS AN INTERNAL STANDARD. FULL SPECTRUM GC-MASS SPECTROMETRY WAS ALSO USED TO VERIFY THAT ABA WAS PRESENT IN A SAMPLE ASSAYED QUANTITATIVELY BY BOTH ELISA AND GC-MS-SIM.« less

  15. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Imamura, Kayo; Matsuura, Takanori; Ye, Zhengmao

    Disproportionating enzyme from potato was crystallized and preliminarily analyzed using X-ray diffraction. Disproportionating enzyme (D-enzyme; EC 2.4.1.25) is a 59 kDa protein that belongs to the α-amylase family. D-enzyme catalyses intramolecular and intermolecular transglycosylation reactions of α-1,4 glucan. A crystal of the D-enzyme from potato was obtained by the hanging-drop vapour-diffusion method. Preliminary X-ray data showed that the crystal diffracts to 2.0 Å resolution and belongs to space group C222{sub 1}, with unit-cell parameters a = 69.7, b = 120.3, c = 174.2 Å.

  16. Materials for Microfluidic Immunoassays: A Review.

    PubMed

    Mou, Lei; Jiang, Xingyu

    2017-08-01

    Conventional immunoassays suffer from at least one of these following limitations: long processing time, high costs, poor user-friendliness, technical complexity, poor sensitivity and specificity. Microfluidics, a technology characterized by the engineered manipulation of fluids in channels with characteristic lengthscale of tens of micrometers, has shown considerable promise for improving immunoassays that could overcome these limitations in medical diagnostics and biology research. The combination of microfluidics and immunoassay can detect biomarkers with faster assay time, reduced volumes of reagents, lower power requirements, and higher levels of integration and automation compared to traditional approaches. This review focuses on the materials-related aspects of the recent advances in microfluidics-based immunoassays for point-of-care (POC) diagnostics of biomarkers. We compare the materials for microfluidic chips fabrication in five aspects: fabrication, integration, function, modification and cost, and describe their advantages and drawbacks. In addition, we review materials for modifying antibodies to improve the performance of the reaction of immunoassay. We also review the state of the art in microfluidic immunoassays POC platforms, from the laboratory to routine clinical practice, and also commercial products in the market. Finally, we discuss the current challenges and future developments in microfluidic immunoassays. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  17. Evaluation of commercial multi-drug oral fluid devices to identify 39 new amphetamine-designer drugs.

    PubMed

    Nieddu, Maria; Burrai, Lucia; Trignano, Claudia; Boatto, Gianpiero

    2014-03-01

    Recently, the diffusion on the black market of new psychoactive substances not controlled and often sold as 'legal highs', is exponentially increasing in Europe. Generally, the first analysis for these drugs involves an immunoassay screening in urine or plasma. Actually, there is growing interest in the use of oral fluid (OF) as alternative specimen over conventional biological fluids for drug testing, because of the significant advantages, as a non-invasive collection under direct observation without undue embarrassment or invasion of privacy, and a good correlation with plasma analytical data. Few assays have been developed for detection of new psychoactive compounds in biological samples, so it is important to investigate how they may or may not react in pre-existing commercial immunoassays. In this paper, two different multi-drugs oral fluid screen devices (OFDs) (Screen® Multi-Drug OFD and GIMA One Step Multi-Line Screen Test OFD) were evaluated to determine the cross-reactivity of thirty-nine new amphetamine designer drugs, including twelve substances officially recognized as illicit by italian legislation. Cross-reactivity towards most drugs analyzed was <1 in assays targeting amphetamine (AMP) or methamphetamine (MET). Only two (p-methoxyamphetamine and p-methoxymethamphetamine) of all tested amphetamines gave a positive result. Copyright © 2013 Elsevier Ireland Ltd. All rights reserved.

  18. Detection of xanthine oxidase and immunologically related proteins in fractions from bovine mammary tissue and milk after electrophoresis in polyacrylamide gels containing sodium dodecyl sulphate.

    PubMed Central

    Mather, I H; Sullivan, C H; Madara, P J

    1982-01-01

    A solid-phase immunoassay was used to detect xanthine oxidase in fractions from bovine mammary glands after electrophoresis in polyacrylamide gels containing sodium dodecyl sulphate. Under these conditions the major proportion of xanthine oxidase in either mammary tissue or mild could be recovered as a protein of mol.wt. 150 000. In mammary tissue approx. 80% of the enzyme was in a soluble form and the remainder was accounted for in either 'mitochondrial' or microsomal fractions after tissue homogenization and fractionation. Affinity chromatography of either detergent-solubilized microsomal membranes or postmicrosomal supernatants on immobilized antibody to xanthine oxidase yielded a single protein that cross-reacted with antibody to the enzyme. In milk presumptive degradation products of the enzyme were detected in minor quantities with mol.wts. of 43 000 in the whey fraction and 90 000 in fat-globule membrane. Only the undegraded enzyme was present in the skim-milk membrane fraction. Xanthine oxidase is therefore synthesized and secreted as a protein with a monomeric mol.wt. of 150 000 and is not subjected to extensive proteolytic degradation during the storage of milk in mammary alveoli. The significance of the results is discussed in relation to the overall protein composition of the membranes of milk-fat globules and skim milk. Images Fig. 1. Fig. 2. Fig. 3. PMID:7046730

  19. A theoretical study of concentration of profiles of primary cytochemical-enzyme reaction products in membrane-bound cell organelles and its application to lysosomal acid phosphatase.

    PubMed

    Cornelisse, C J; Hermens, W T; Joe, M T; Duijndam, W A; van Duijn, P

    1976-11-01

    A numerical method was developed for computing the steady-state concentration gradient of a diffusible enzyme reaction product in a membrane-limited compartment of a simplified theoretical cell model. In cytochemical enzyme reactions proceeding according to the metal-capture principle, the local concentration of the primary reaction product is an important factor in the onset of the precipitation process and in the distribution of the final reaction product. The following variables were incorporated into the model: enzyme activity, substrate concentration, Km, diffusion coefficient of substrate and product, particle radius and cell radius. The method was applied to lysosomal acid phosphatase. Numerical values for the variables were estimated from experimental data in the literature. The results show that the calculated phosphate concentrations inside lysosomes are several orders of magnitude lower than the critical concentrations for efficient phosphate capture found in a previous experimental model study. Reasons for this apparent discrepancy are discussed.

  20. Use of polymerase chain reaction technique to confirm VecTest screening results in Plasmodium falciparum and Plasmodium vivax VK 210 laboratory-infected Anopheles stephensi mosquitoes.

    PubMed

    Santos-Ciminera, Patricia D; Acheé, Nicole L; Quinnan, Gerald V; Roberts, Donald R

    2004-09-01

    We evaluated polymerase chain reaction (PCR) to confirm immunoassays for malaria parasites in mosquito pools after a failure to detect malaria with PCR during an outbreak in which pools tested positive using VecTest and enzyme-linked immunosorbent assay (ELISA). We combined VecTest, ELISA, and PCR to detect Plasmodium falciparum and Plasmodium vivax VK 210. Each mosquito pool, prepared in triplicate, consisted of 1 exposed Anopheles stephensi and up to 9 unfed mosquitoes. The results of VecTest and ELISA were concordant. DNA from a subset of the pools, 1 representative of each ratio of infected to uninfected mosquitoes, was extracted and used as template in PCR. All P. vivax pools were PCR positive but some needed additional processing for removal of apparent inhibitors before positive results were obtained. One of the pools selected for P. falciparum was negative by PCR, probably because of losses or contamination during DNA extraction; 2 remaining pools at this ratio were PCR positive. Testing pools by VecTest, ELISA, and PCR is feasible, and PCR is useful for confirmation of immunoassays. An additional step might be needed to remove potential inhibitors from pools prior to PCR.