[Feasibility Study on Digital Signal Processor and Gear Pump of Uroflowmeter Calibration Device].
Yuan, Qing; Ji, Jun; Gao, Jiashuo; Wang, Lixin; Xiao, Hong
2016-08-01
It will cause hidden trouble on clinical application if the uroflowmeter is out of control.This paper introduces a scheme of uroflowmeter calibration device based on digital signal processor(DSP)and gear pump and shows studies of its feasibility.According to the research plan,we analyzed its stability,repeatability and linearity by building a testing system and carried out experiments on it.The flow test system is composed of DSP,gear pump and other components.The test results showed that the system could produce a stable water flow with high precision of repeated measurement and different flow rate.The test system can calibrate the urine flow rate well within the range of 9~50mL/s which has clinical significance,and the flow error is less than 1%,which meets the technical requirements of the calibration apparatus.The research scheme of uroflowmeter calibration device on DSP and gear pump is feasible.
Adaptation of hidden Markov models for recognizing speech of reduced frame rate.
Lee, Lee-Min; Jean, Fu-Rong
2013-12-01
The frame rate of the observation sequence in distributed speech recognition applications may be reduced to suit a resource-limited front-end device. In order to use models trained using full-frame-rate data in the recognition of reduced frame-rate (RFR) data, we propose a method for adapting the transition probabilities of hidden Markov models (HMMs) to match the frame rate of the observation. Experiments on the recognition of clean and noisy connected digits are conducted to evaluate the proposed method. Experimental results show that the proposed method can effectively compensate for the frame-rate mismatch between the training and the test data. Using our adapted model to recognize the RFR speech data, one can significantly reduce the computation time and achieve the same level of accuracy as that of a method, which restores the frame rate using data interpolation.
Automated Cough Assessment on a Mobile Platform
2014-01-01
The development of an Automated System for Asthma Monitoring (ADAM) is described. This consists of a consumer electronics mobile platform running a custom application. The application acquires an audio signal from an external user-worn microphone connected to the device analog-to-digital converter (microphone input). This signal is processed to determine the presence or absence of cough sounds. Symptom tallies and raw audio waveforms are recorded and made easily accessible for later review by a healthcare provider. The symptom detection algorithm is based upon standard speech recognition and machine learning paradigms and consists of an audio feature extraction step followed by a Hidden Markov Model based Viterbi decoder that has been trained on a large database of audio examples from a variety of subjects. Multiple Hidden Markov Model topologies and orders are studied. Performance of the recognizer is presented in terms of the sensitivity and the rate of false alarm as determined in a cross-validation test. PMID:25506590
An application of the MPP to the interactive manipulation of stereo images of digital terrain models
NASA Technical Reports Server (NTRS)
Pol, Sanjay; Mcallister, David; Davis, Edward
1987-01-01
Massively Parallel Processor algorithms were developed for the interactive manipulation of flat shaded digital terrain models defined over grids. The emphasis is on real time manipulation of stereo images. Standard graphics transformations are applied to a 128 x 128 grid of elevations followed by shading and a perspective projection to produce the right eye image. The surface is then rendered using a simple painter's algorithm for hidden surface removal. The left eye image is produced by rotating the surface 6 degs about the viewer's y axis followed by a perspective projection and rendering of the image as described above. The left and right eye images are then presented on a graphics device using standard stereo technology. Performance evaluations and comparisons are presented.
Using spread spectrum for AMR magnetic sensor
NASA Astrophysics Data System (ADS)
Vala, David
2016-09-01
This contribution describe invention of Magnetometer with protection against detection by electronic counter- measure (ECM) registered by Czech patent office as patent no. 305322.1 Magnetic sensors are often part of dual use or security instruments and equipment. For this purpose is very interesting to build sensor with is hidden against electronic countermeasure. In this case is very important level and behavior of electromagnetic noise produced by sensor. And also electromagnetic compatibility of electronic devices is the area which significant grows nowadays too. As the consequence of this growth there is a continuous process of making more strict standards focused on electromagnetic radiation of electronic devices. Sensors technology begins to be a part of these issues due sensors bandwidth increasing and approaching to frequency of radio communication band. Nowadays microcontrollers and similar digital circuits are integrated into sensors devices and it brings new sources of electromagnetic radiation in modern smart sensors.
StegoWall: blind statistical detection of hidden data
NASA Astrophysics Data System (ADS)
Voloshynovskiy, Sviatoslav V.; Herrigel, Alexander; Rytsar, Yuri B.; Pun, Thierry
2002-04-01
Novel functional possibilities, provided by recent data hiding technologies, carry out the danger of uncontrolled (unauthorized) and unlimited information exchange that might be used by people with unfriendly interests. The multimedia industry as well as the research community recognize the urgent necessity for network security and copyright protection, or rather the lack of adequate law for digital multimedia protection. This paper advocates the need for detecting hidden data in digital and analog media as well as in electronic transmissions, and for attempting to identify the underlying hidden data. Solving this problem calls for the development of an architecture for blind stochastic hidden data detection in order to prevent unauthorized data exchange. The proposed architecture is called StegoWall; its key aspects are the solid investigation, the deep understanding, and the prediction of possible tendencies in the development of advanced data hiding technologies. The basic idea of our complex approach is to exploit all information about hidden data statistics to perform its detection based on a stochastic framework. The StegoWall system will be used for four main applications: robust watermarking, secret communications, integrity control and tamper proofing, and internet/network security.
Taking Impressions of Hidden Cavity Walls
NASA Technical Reports Server (NTRS)
Burley, D.; Mayer, W.
1987-01-01
Lightweight, portable internal-molding device makes it possible to measure radii of, or examine contours of, passageways in hidden or complicated cavities. With device, measurements made in field, without returning assemblies to shop or laboratory for inspection. Molding head expands when compressed air applied. Inflatable tubes around head perform dual sealing and aligning function.
Neural node network and model, and method of teaching same
Parlos, A.G.; Atiya, A.F.; Fernandez, B.; Tsai, W.K.; Chong, K.T.
1995-12-26
The present invention is a fully connected feed forward network that includes at least one hidden layer. The hidden layer includes nodes in which the output of the node is fed back to that node as an input with a unit delay produced by a delay device occurring in the feedback path (local feedback). Each node within each layer also receives a delayed output (crosstalk) produced by a delay unit from all the other nodes within the same layer. The node performs a transfer function operation based on the inputs from the previous layer and the delayed outputs. The network can be implemented as analog or digital or within a general purpose processor. Two teaching methods can be used: (1) back propagation of weight calculation that includes the local feedback and the crosstalk or (2) more preferably a feed forward gradient decent which immediately follows the output computations and which also includes the local feedback and the crosstalk. Subsequent to the gradient propagation, the weights can be normalized, thereby preventing convergence to a local optimum. Education of the network can be incremental both on and off-line. An educated network is suitable for modeling and controlling dynamic nonlinear systems and time series systems and predicting the outputs as well as hidden states and parameters. The educated network can also be further educated during on-line processing. 21 figs.
Neural node network and model, and method of teaching same
Parlos, Alexander G.; Atiya, Amir F.; Fernandez, Benito; Tsai, Wei K.; Chong, Kil T.
1995-01-01
The present invention is a fully connected feed forward network that includes at least one hidden layer 16. The hidden layer 16 includes nodes 20 in which the output of the node is fed back to that node as an input with a unit delay produced by a delay device 24 occurring in the feedback path 22 (local feedback). Each node within each layer also receives a delayed output (crosstalk) produced by a delay unit 36 from all the other nodes within the same layer 16. The node performs a transfer function operation based on the inputs from the previous layer and the delayed outputs. The network can be implemented as analog or digital or within a general purpose processor. Two teaching methods can be used: (1) back propagation of weight calculation that includes the local feedback and the crosstalk or (2) more preferably a feed forward gradient decent which immediately follows the output computations and which also includes the local feedback and the crosstalk. Subsequent to the gradient propagation, the weights can be normalized, thereby preventing convergence to a local optimum. Education of the network can be incremental both on and off-line. An educated network is suitable for modeling and controlling dynamic nonlinear systems and time series systems and predicting the outputs as well as hidden states and parameters. The educated network can also be further educated during on-line processing.
Topography of hidden objects using THz digital holography with multi-beam interferences.
Valzania, Lorenzo; Zolliker, Peter; Hack, Erwin
2017-05-15
We present a method for the separation of the signal scattered from an object hidden behind a THz-transparent sample in the framework of THz digital holography in reflection. It combines three images of different interference patterns to retrieve the amplitude and phase distribution of the object beam. Comparison of simulated with experimental images obtained from a metallic resolution target behind a Teflon plate demonstrates that the interference patterns can be described in the simple form of three-beam interference. Holographic reconstructions after the application of the method show a considerable improvement compared to standard reconstructions exclusively based on Fourier transform phase retrieval.
Digital Textbooks and Digital Divide in West Virginia: Teachers' Hidden Works
ERIC Educational Resources Information Center
Ravenscroft, Matthew D.
2017-01-01
Digital textbooks are replacing print books in school districts across the United States due to their adaptability for students with special needs, enhanced student interest, and lower cost. This is also true in the rural state of West Virginia which lags the U.S. in broadband Internet saturation. Therefore, the purpose of this study was to…
"Glitch Logic" and Applications to Computing and Information Security
NASA Technical Reports Server (NTRS)
Stoica, Adrian; Katkoori, Srinivas
2009-01-01
This paper introduces a new method of information processing in digital systems, and discusses its potential benefits to computing and information security. The new method exploits glitches caused by delays in logic circuits for carrying and processing information. Glitch processing is hidden to conventional logic analyses and undetectable by traditional reverse engineering techniques. It enables the creation of new logic design methods that allow for an additional controllable "glitch logic" processing layer embedded into a conventional synchronous digital circuits as a hidden/covert information flow channel. The combination of synchronous logic with specific glitch logic design acting as an additional computing channel reduces the number of equivalent logic designs resulting from synthesis, thus implicitly reducing the possibility of modification and/or tampering with the design. The hidden information channel produced by the glitch logic can be used: 1) for covert computing/communication, 2) to prevent reverse engineering, tampering, and alteration of design, and 3) to act as a channel for information infiltration/exfiltration and propagation of viruses/spyware/Trojan horses.
Spread spectrum image steganography.
Marvel, L M; Boncelet, C R; Retter, C T
1999-01-01
In this paper, we present a new method of digital steganography, entitled spread spectrum image steganography (SSIS). Steganography, which means "covered writing" in Greek, is the science of communicating in a hidden manner. Following a discussion of steganographic communication theory and review of existing techniques, the new method, SSIS, is introduced. This system hides and recovers a message of substantial length within digital imagery while maintaining the original image size and dynamic range. The hidden message can be recovered using appropriate keys without any knowledge of the original image. Image restoration, error-control coding, and techniques similar to spread spectrum are described, and the performance of the system is illustrated. A message embedded by this method can be in the form of text, imagery, or any other digital signal. Applications for such a data-hiding scheme include in-band captioning, covert communication, image tamperproofing, authentication, embedded control, and revision tracking.
Resisting Age Bias in Digital Literacy Research
ERIC Educational Resources Information Center
Bowen, Lauren Marshall
2011-01-01
Through an eighty-one-year-old woman's literacy narrative, I argue that literacy researchers should pay greater attention to elder writers, readers, and learners. Particularly as notions of literacy shift in digital times, the perspective of a lifespan can reveal otherwise hidden complexities of literacy, including the motivational impact of…
Online Farsi digit recognition using their upper half structure
NASA Astrophysics Data System (ADS)
Ghods, Vahid; Sohrabi, Mohammad Karim
2015-03-01
In this paper, we investigated the efficiency of upper half Farsi numerical digit structure. In other words, half of data (upper half of the digit shapes) was exploited for the recognition of Farsi numerical digits. This method can be used for both offline and online recognition. Half of data is more effective in speed process, data transfer and in this application accuracy. Hidden Markov model (HMM) was used to classify online Farsi digits. Evaluation was performed by TMU dataset. This dataset contains more than 1200 samples of online handwritten Farsi digits. The proposed method yielded more accuracy in recognition rate.
ERIC Educational Resources Information Center
Hartong, Sigrid
2016-01-01
The past few decades have witnessed a global enforcement of "governance by data" in education policy, including a significant increase of assessments and quantified evaluation. Within this context, this article focuses particularly on the intensifying evolvement of new (digital) information technologies and "mediated"…
Barratt, Monica J; Potter, Gary R; Wouters, Marije; Wilkins, Chris; Werse, Bernd; Perälä, Jussi; Pedersen, Michael Mulbjerg; Nguyen, Holly; Malm, Aili; Lenton, Simon; Korf, Dirk; Klein, Axel; Heyde, Julie; Hakkarainen, Pekka; Frank, Vibeke Asmussen; Decorte, Tom; Bouchard, Martin; Blok, Thomas
2015-03-01
Internet-mediated research methods are increasingly used to access hidden populations. The International Cannabis Cultivation Questionnaire (ICCQ) is an online survey designed to facilitate international comparisons into the relatively under-researched but increasingly significant phenomenon of domestic cannabis cultivation. The Global Cannabis Cultivation Research Consortium has used the ICCQ to survey over 6000 cannabis cultivators across 11 countries. In this paper, we describe and reflect upon our methodological approach, focusing on the digital and traditional recruitment methods used to access this hidden population and the challenges of working across multiple countries, cultures and languages. Descriptive statistics showing eligibility and completion rates and recruitment source by country of residence. Over three quarters of eligible respondents who were presented with the survey were included in the final sample of n=6528. English-speaking countries expended more effort to recruit participants than non-English-speaking countries. The most effective recruitment modes were cannabis websites/groups (33%), Facebook (14%) and news articles (11%). While respondents recruited through news articles were older, growing practice variables were strikingly similar between these main recruitment modes. Through this process, we learnt that there are trade-offs between hosting multiple surveys in each country vs. using one integrated database. We also found that although perceived anonymity is routinely assumed to be a benefit of using digital research methodologies, there are significant limits to research participant anonymity in the current era of mass digital surveillance, especially when the target group is particularly concerned about evading law enforcement. Finally, we list a number of specific recommendations for future researchers utilising Internet-mediated approaches to researching hidden populations. Copyright © 2014 Elsevier B.V. All rights reserved.
Training, Sharing or Cheating? Gamer Strategies to Get a Digital Upper Hand
ERIC Educational Resources Information Center
Mortensen, Torill Elvira
2010-01-01
Digital game-players devote a large amount of their time to discovering rules hidden in the code and discoverable through empirical study, experiments, and developing or rediscovering the mathematical formulae governing the code. They do this through their own independent play as they test areas, gear and abilities, through data mining using…
NASA Astrophysics Data System (ADS)
Ko, Heasin; Lim, Kyongchun; Oh, Junsang; Rhee, June-Koo Kevin
2016-10-01
Quantum channel loopholes due to imperfect implementations of practical devices expose quantum key distribution (QKD) systems to potential eavesdropping attacks. Even though QKD systems are implemented with optical devices that are highly selective on spectral characteristics, information theory-based analysis about a pertinent attack strategy built with a reasonable framework exploiting it has never been clarified. This paper proposes a new type of trojan horse attack called hidden pulse attack that can be applied in a plug-and-play QKD system, using general and optimal attack strategies that can extract quantum information from phase-disturbed quantum states of eavesdropper's hidden pulses. It exploits spectral characteristics of a photodiode used in a plug-and-play QKD system in order to probe modulation states of photon qubits. We analyze the security performance of the decoy-state BB84 QKD system under the optimal hidden pulse attack model that shows enormous performance degradation in terms of both secret key rate and transmission distance.
Chao, Hui-Mei; Hsu, Chin-Ming; Miaou, Shaou-Gang
2002-03-01
A data-hiding technique called the "bipolar multiple-number base" was developed to provide capabilities of authentication, integration, and confidentiality for an electronic patient record (EPR) transmitted among hospitals through the Internet. The proposed technique is capable of hiding those EPR related data such as diagnostic reports, electrocardiogram, and digital signatures from doctors or a hospital into a mark image. The mark image could be the mark of a hospital used to identify the origin of an EPR. Those digital signatures from doctors and a hospital could be applied for the EPR authentication. Thus, different types of medical data can be integrated into the same mark image. The confidentiality is ultimately achieved by decrypting the EPR related data and digital signatures with an exact copy of the original mark image. The experimental results validate the integrity and the invisibility of the hidden EPR related data. This newly developed technique allows all of the hidden data to be separated and restored perfectly by authorized users.
Military Review: The Professional Journal of the U.S. Army. January-February 2002
2002-02-01
Internet.”9 He accuses bin Laden of hiding maps and photos of targets and of posting instructions on sports chat rooms, porno - graphic bulletin boards...anything unusual. Messages can be hidden in audio, video , or still image files, with information stored in the least significant bits of a digitized file...steganography, embedding secret messages in other messages to prevent observers from suspecting anything unusual. Messages can be hidden in audio, video , or
Hidden Area and Mechanical Nonlinearities in Freestanding Graphene.
Nicholl, Ryan J T; Lavrik, Nickolay V; Vlassiouk, Ivan; Srijanto, Bernadeta R; Bolotin, Kirill I
2017-06-30
We investigated the effect of out-of-plane crumpling on the mechanical response of graphene membranes. In our experiments, stress was applied to graphene membranes using pressurized gas while the strain state was monitored through two complementary techniques: interferometric profilometry and Raman spectroscopy. By comparing the data obtained through these two techniques, we determined the geometric hidden area which quantifies the crumpling strength. While the devices with hidden area ∼0% obeyed linear mechanics with biaxial stiffness 428±10 N/m, specimens with hidden area in the range 0.5%-1.0% were found to obey an anomalous nonlinear Hooke's law with an exponent ∼0.1.
Hidden Area and Mechanical Nonlinearities in Freestanding Graphene
NASA Astrophysics Data System (ADS)
Nicholl, Ryan J. T.; Lavrik, Nickolay V.; Vlassiouk, Ivan; Srijanto, Bernadeta R.; Bolotin, Kirill I.
2017-06-01
We investigated the effect of out-of-plane crumpling on the mechanical response of graphene membranes. In our experiments, stress was applied to graphene membranes using pressurized gas while the strain state was monitored through two complementary techniques: interferometric profilometry and Raman spectroscopy. By comparing the data obtained through these two techniques, we determined the geometric hidden area which quantifies the crumpling strength. While the devices with hidden area ˜0 % obeyed linear mechanics with biaxial stiffness 428 ±10 N /m , specimens with hidden area in the range 0.5%-1.0% were found to obey an anomalous nonlinear Hooke's law with an exponent ˜0.1 .
21 CFR 892.2030 - Medical image digitizer.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Medical image digitizer. 892.2030 Section 892.2030...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2030 Medical image digitizer. (a) Identification. A medical image digitizer is a device intended to convert an analog medical image into a digital...
21 CFR 892.2030 - Medical image digitizer.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Medical image digitizer. 892.2030 Section 892.2030...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2030 Medical image digitizer. (a) Identification. A medical image digitizer is a device intended to convert an analog medical image into a digital...
21 CFR 892.2030 - Medical image digitizer.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Medical image digitizer. 892.2030 Section 892.2030...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2030 Medical image digitizer. (a) Identification. A medical image digitizer is a device intended to convert an analog medical image into a digital...
21 CFR 892.2030 - Medical image digitizer.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Medical image digitizer. 892.2030 Section 892.2030...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.2030 Medical image digitizer. (a) Identification. A medical image digitizer is a device intended to convert an analog medical image into a digital...
The Future of Warfare and Impact of Space Operations
2011-01-01
cyber warfare is occurring as a preferred method of conflict between large players on the global stage. Smaller players also have reasons to avoid conventional warfare and remain hidden. In Iraq and Afghanistan, those who fight against us attempt to remain hidden. The individual who places an improvised explosive device (IED) attempts to engage us without exposure or identification. Those who aid the individual emplacing an IED do so with hidden networks of support. The IED is an anonymous weapon. Both cyber warfare and insurgent use of IEDs depend
Camouflaging in Digital Image for Secure Communication
NASA Astrophysics Data System (ADS)
Jindal, B.; Singh, A. P.
2013-06-01
The present paper reports on a new type of camouflaging in digital image for hiding crypto-data using moderate bit alteration in the pixel. In the proposed method, cryptography is combined with steganography to provide a two layer security to the hidden data. The novelty of the algorithm proposed in the present work lies in the fact that the information about hidden bit is reflected by parity condition in one part of the image pixel. The remaining part of the image pixel is used to perform local pixel adjustment to improve the visual perception of the cover image. In order to examine the effectiveness of the proposed method, image quality measuring parameters are computed. In addition to this, security analysis is also carried by comparing the histograms of cover and stego images. This scheme provides a higher security as well as robustness to intentional as well as unintentional attacks.
Endoscopic pulsed digital holography for 3D measurements
NASA Astrophysics Data System (ADS)
Saucedo, A. Tonatiuh; Mendoza Santoyo, Fernando; de La Torre-Ibarra, Manuel; Pedrini, Giancarlo; Osten, Wolfgang
2006-02-01
A rigid endoscope and three different object illumination source positions are used in pulsed digital holography to measure the three orthogonal displacement components from hidden areas of a harmonically vibrating metallic cylinder. In order to obtain simultaneous 3D information from the optical set up, it is necessary to match the optical paths of each of the reference object beam pairs, but to incoherently mismatch the three reference object beam pairs, such that three pulsed digital holograms are incoherently recorded within a single frame of the CCD sensor. The phase difference is obtained using the Fourier method and by subtracting two digital holograms captured for two different object positions.
NASA Astrophysics Data System (ADS)
Gasanova, Svetlana; Hermon, Sorin
2017-07-01
The present study describes a novel approach to the study of hidden by integrating the non-invasive micro-X-Ray Fluorescence spectroscopy, X-radiography and digital microscopy. The case study analysed is a portrait of a male figure discovered under the painting of Ecce Homo, attributed to Titian's studio with an estimated date in the 1550s. The X-radiography images exposed the details of the underpainting, which appeared to be a nearly finished portrait of a standing man, overpainted by the current composition of Ecce Homo at a 180° angle. The microscopy observations of the upper painting's cracks and flaked areas enabled the study of the exposed underlayers in terms of their colour appearance and pigment particles. The subsequent pigment analysis was performed by micro-XRF. Since the described XRF analysis was performed not in scanner mode, the correct selection of the measurement spots for the micro analysis and separation between pigments of the lower and the upper painting was of paramount importance. The described approach for spot selection was based on the results of the preceding X-radiography and digital microscopy tests. The presence of lead white, vermilion, copper green and iron earth in the underlying portrait was confirmed by the multiple point XRF analysis of Pb, Hg, Cu, Fe and Mn lines. The described investigation method proved to be useful in the identification of the pigments of the underlying painting and consequently assisted in the tentative reconstruction of its colour palette. Moreover, the undertaken approach allowed discovering the potential of micro-XRF technique in the study of hidden compositions.
Digitally-bypassed transducers: interfacing digital mockups to real-time medical equipment.
Sirowy, Scott; Givargis, Tony; Vahid, Frank
2009-01-01
Medical device software is sometimes initially developed by using a PC simulation environment that executes models of both the device and a physiological system, and then later by connecting the actual medical device to a physical mockup of the physiological system. An alternative is to connect the medical device to a digital mockup of the physiological system, such that the device believes it is interacting with a physiological system, but in fact all interaction is entirely digital. Developing medical device software by interfacing with a digital mockup enables development without costly or dangerous physical mockups, and enables execution that is faster or slower than real time. We introduce digitally-bypassed transducers, which involve a small amount of hardware and software additions, and which enable interfacing with digital mockups.
Handwritten digits recognition using HMM and PSO based on storks
NASA Astrophysics Data System (ADS)
Yan, Liao; Jia, Zhenhong; Yang, Jie; Pang, Shaoning
2010-07-01
A new method for handwritten digits recognition based on hidden markov model (HMM) and particle swarm optimization (PSO) is proposed. This method defined 24 strokes with the sense of directional, to make up for the shortage that is sensitive in choice of stating point in traditional methods, but also reduce the ambiguity caused by shakes. Make use of excellent global convergence of PSO; improving the probability of finding the optimum and avoiding local infinitesimal obviously. Experimental results demonstrate that compared with the traditional methods, the proposed method can make most of the recognition rate of handwritten digits improved.
NASA Astrophysics Data System (ADS)
Wang, Tianyang; Jerrett, Michael; Sinsheimer, Peter; Zhu, Yifang
2016-11-01
The Volkswagen Group of America (VW) was found by the US Environmental Protection Agency (EPA) and the California Air Resources Board (CARB) to have installed "defeat devices" and emit more oxides of nitrogen (NOx) than permitted under current EPA standards. In this paper, we quantify the hidden NOx emissions from this so-called VW scandal and the resulting public health impacts in California. The NOx emissions are calculated based on VW road test data and the CARB Emission Factors (EMFAC) model. Cumulative hidden NOx emissions from 2009 to 2015 were estimated to be over 3500 tons. Adult mortality changes were estimated based on ambient fine particulate matter (PM2.5) change due to secondary nitrate formation and the related concentration-response functions. We estimated that hidden NOx emissions from 2009 to 2015 have resulted in a total of 12 PM2.5-associated adult mortality increases in California. Most of the mortality increase happened in metropolitan areas, due to their high population and vehicle density.
NASA Technical Reports Server (NTRS)
Trosin, J.
1985-01-01
Use of the Display AButments (DAB) which plots PAN AIR geometries is presented. The DAB program creates hidden line displays of PAN AIR geometries and labels specified geometry components, such as abutments, networks, and network edges. It is used to alleviate the very time consuming and error prone abutment list checking phase of developing a valid PAN AIR geometry, and therefore represents a valuable tool for debugging complex PAN AIR geometry definitions. DAB is written in FORTRAN 77 and runs on a Digital Equipment Corporation VAX 11/780 under VMS. It utilizes a special color version of the SKETCH hidden line analysis routine.
Agreement and reading time for differently-priced devices for the digital capture of X-ray films.
Salazar, Antonio José; Camacho, Juan Camilo; Aguirre, Diego Andrés
2012-03-01
We assessed the reliability of three digital capture devices: a film digitizer (which cost US $15,000), a flat-bed scanner (US $1800) and a digital camera (US $450). Reliability was measured as the agreement between six observers when reading images acquired from a single device and also in terms of the pair-device agreement. The images were 136 chest X-ray cases. The variables measured were the interstitial opacities distribution, interstitial patterns, nodule size and percentage pneumothorax size. The agreement between the six readers when reading images acquired from a single device was similar for the three devices. The pair-device agreements were moderate for all variables. There were significant differences in reading-time between devices: the mean reading-time for the film digitizer was 93 s, it was 59 s for the flat-bed scanner and 70 s for the digital camera. Despite the differences in their cost, there were no substantial differences in the performance of the three devices.
Socio-inspired ICT. Towards a socially grounded society-ICT symbiosis
NASA Astrophysics Data System (ADS)
Ferscha, A.; Farrahi, K.; van den Hoven, J.; Hales, D.; Nowak, A.; Lukowicz, P.; Helbing, D.
2012-11-01
Modern ICT (Information and Communication Technology) has developed a vision where the "computer" is no longer associated with the concept of a single device or a network of devices, but rather the entirety of situated services originating in a digital world, which are perceived through the physical world. It is observed that services with explicit user input and output are becoming to be replaced by a computing landscape sensing the physical world via a huge variety of sensors, and controlling it via a plethora of actuators. The nature and appearance of computing devices is changing to be hidden in the fabric of everyday life, invisibly networked, and omnipresent, with applications greatly being based on the notions of context and knowledge. Interaction with such globe spanning, modern ICT systems will presumably be more implicit, at the periphery of human attention, rather than explicit, i.e. at the focus of human attention.Socio-inspired ICT assumes that future, globe scale ICT systems should be viewed as social systems. Such a view challenges research to identify and formalize the principles of interaction and adaptation in social systems, so as to be able to ground future ICT systems on those principles. This position paper therefore is concerned with the intersection of social behaviour and modern ICT, creating or recreating social conventions and social contexts through the use of pervasive, globe-spanning, omnipresent and participative ICT.
Detection and Localization of Money Bills Concealed Behind Wooden Walls Using Compton Scattering
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wart, Jason A. van; Hussein, Esam M.A.; Waller, Edward J
2005-05-15
This work presents a portable device for detecting visually obscured contraband money bills that may be hidden within conventional household walls for the purpose of avoiding confiscation. The device utilizes the Compton backscattering of photons emitted from a collimated {sup 241}Am source. The scattered photons are detected with a thin NaI(Tl) detector, either over a wide field of view for surface scanning of the wall or within a confined view field for depth scanning. The design of the device was optimized for best density contrast and highest count rate for a given source activity. It was shown that the minimummore » detectable amount of contraband, with >95% confidence level, is 86 paper bills. The contraband was detectable when hidden in household walls made of gyprock or wooden paneling, even when masked by higher density materials such as metallic piping. The device's capability exceeded those of commercially available density-based portable contraband detectors.« less
2010-11-05
The Food and Drug Administration (FDA) is announcing the reclassification of the full-field digital mammography (FFDM) system from class III (premarket approval) to class II (special controls). The device type is intended to produce planar digital x-ray images of the entire breast; this generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component parts, and accessories. The special control that will apply to the device is the guidance document entitled "Class II Special Controls Guidance Document: Full-Field Digital Mammography System." FDA is reclassifying the device into class II (special controls) because general controls along with special controls will provide a reasonable assurance of safety and effectiveness of the device. Elsewhere in this issue of the Federal Register, FDA is announcing the availability of the guidance document that will serve as the special control for this device.
The growth crisis--and how to escape it.
Slywotzky, Adrian J; Wise, Richard
2002-07-01
At a time when companies are poised to seize the growth opportunities of a rebounding economy, many of them, whether they know it or not, face a growth crisis. Even during the boom years of the past decade, only a small fraction of companies enjoyed consistent double-digit revenue growth. And those that did often achieved it through short-term measures--such as mergers and inflated price increases--that don't provide the foundation for growth over the long term. But there is a way out of this predicament. The authors claim that companies can achieve sustained growth by leveraging their "hidden assets," a wide array of underused, intangible capabilities and advantages that most established companies already hold. To date, much of the research on intangible assets has centered on intellectual property and brand recognition. But in this article, the authors uncover a host of other assets that can help spark growth. They identify four major categories of hidden assets: customer relationships, strategic real estate, networks, and information. And they illustrate each with an example of a company that has creatively used its hidden assets to produce new sources of revenue. Executives have spent years learning to create growth using products, facilities, and working capital. But they should really focus on mobilizing their hidden assets to serve their customers' higher-order needs--in other words, create offerings that make customers' lives easier, better, or less expensive. Making that shift in mind-set isn't easy, admit the authors, but companies that do it may not only create meaningful new value for their customers but also produce double-digit revenue and earnings growth for investors.
Quantum Steering Beyond Instrumental Causal Networks
NASA Astrophysics Data System (ADS)
Nery, R. V.; Taddei, M. M.; Chaves, R.; Aolita, L.
2018-04-01
We theoretically predict, and experimentally verify with entangled photons, that outcome communication is not enough for hidden-state models to reproduce quantum steering. Hidden-state models with outcome communication correspond, in turn, to the well-known instrumental processes of causal inference but in the one-sided device-independent scenario of one black-box measurement device and one well-characterized quantum apparatus. We introduce one-sided device-independent instrumental inequalities to test against these models, with the appealing feature of detecting entanglement even when communication of the black box's measurement outcome is allowed. We find that, remarkably, these inequalities can also be violated solely with steering, i.e., without outcome communication. In fact, an efficiently computable formal quantifier—the robustness of noninstrumentality—naturally arises, and we prove that steering alone is enough to maximize it. Our findings imply that quantum theory admits a stronger form of steering than known until now, with fundamental as well as practical potential implications.
ERIC Educational Resources Information Center
Rauber, Andreas; Bruckner, Robert M.; Aschenbrenner, Andreas; Witvoet, Oliver; Kaiser, Max; Masanes, Julien; Marchionini, Gary; Geisler, Gary; King, Donald W.; Montgomery, Carol Hansen; Rudner, Lawrence M.; Gellmann, Jennifer S.; Miller-Whitehead, Marie; Iverson, Lee
2002-01-01
These six articles discuss Web archives and Web analysis building on data warehouses; international efforts at continuous Web archiving; the Open Video Digital Library; electronic journal collections in academic libraries; online education journals; and an electronic library symposium at the University of British Columbia. (LRW)
47 CFR 90.212 - Provisions relating to the use of scrambling devices and digital voice modulation.
Code of Federal Regulations, 2011 CFR
2011-10-01
... devices and digital voice modulation. 90.212 Section 90.212 Telecommunication FEDERAL COMMUNICATIONS... Standards § 90.212 Provisions relating to the use of scrambling devices and digital voice modulation. (a... emission, subject to the provision of paragraph (d) of this section. (b) The use of digital scrambling...
47 CFR 90.212 - Provisions relating to the use of scrambling devices and digital voice modulation.
Code of Federal Regulations, 2010 CFR
2010-10-01
... devices and digital voice modulation. 90.212 Section 90.212 Telecommunication FEDERAL COMMUNICATIONS... Standards § 90.212 Provisions relating to the use of scrambling devices and digital voice modulation. (a... emission, subject to the provision of paragraph (d) of this section. (b) The use of digital scrambling...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-05-20
... NUCLEAR REGULATORY COMMISSION [NRC-2013-0098] Embedded Digital Devices in Safety-Related Systems... (NRC) is issuing for public comment Draft Regulatory Issue Summary (RIS) 2013-XX, ``Embedded Digital... requirements for the quality and reliability of basic components with embedded digital devices. DATES: Submit...
Salazar, Antonio José; Camacho, Juan Camilo; Aguirre, Diego Andrés
2012-02-01
A common teleradiology practice is digitizing films. The costs of specialized digitizers are very high, that is why there is a trend to use conventional scanners and digital cameras. Statistical clinical studies are required to determine the accuracy of these devices, which are very difficult to carry out. The purpose of this study was to compare three capture devices in terms of their capacity to detect several image characteristics. Spatial resolution, contrast, gray levels, and geometric deformation were compared for a specialized digitizer ICR (US$ 15,000), a conventional scanner UMAX (US$ 1,800), and a digital camera LUMIX (US$ 450, but require an additional support system and a light box for about US$ 400). Test patterns printed in films were used. The results detected gray levels lower than real values for all three devices; acceptable contrast and low geometric deformation with three devices. All three devices are appropriate solutions, but a digital camera requires more operator training and more settings.
Collaborative Estimation in Distributed Sensor Networks
ERIC Educational Resources Information Center
Kar, Swarnendu
2013-01-01
Networks of smart ultra-portable devices are already indispensable in our lives, augmenting our senses and connecting our lives through real time processing and communication of sensory (e.g., audio, video, location) inputs. Though usually hidden from the user's sight, the engineering of these devices involves fierce tradeoffs between energy…
Usability of digital media in patients with COPD: a pilot study.
Cheung, Amy; Janssen, Anton; Amft, Oliver; Wouters, Emiel F M; Spruit, Martijn A
2013-04-01
Digital media can be integrated in tele-monitoring solutions, serving as the main interface between the patient and the caregiver. Consequently, the selection of the most appropriate digital medium for the specified target group is critical to ensure compliance with the tele-monitoring system. This pilot study aims to gather insights from patients with chronic obstructive pulmonary disease (COPD) on the ease-of-use, efficacy, effectiveness, and satisfaction of different types of digital media. Five off-the-shelf digital media devices were tested on nine patients at CIRO+ in Horn, The Netherlands. Usability was evaluated by asking patients to use each device to answer questions related to their symptoms and health status. Subsequently, patients completed a paper-based device usability questionnaire, which assessed prior experience with digital media, device dimensions, device controllability, response speed, screen readability, ease-of-use, and overall satisfaction. After testing all the devices, patients ranked the devices according to their preference. We identified the netbook as the preferred type of device due to its good controllability, fast response time, and large screen size. The smartphone was the least favorite device as patients found the size of the screen to be too small, which made it difficult to interact with. The pilot study has provided important insights to guide the selection of the most appropriate type of digital medium for implementation in tele-monitoring solutions for patients with COPD. As the digital medium is an important interface to the patient in tele-monitoring solutions, it is essential that patients feel motivated to interact with the digital medium on a regular basis.
Front-end electronics for the Muon Portal project
NASA Astrophysics Data System (ADS)
Garozzo, S.; Marano, D.; Bonanno, G.; Grillo, A.; Romeo, G.; Timpanaro, M. C.; Lo Presti, D.; Riggi, F.; Russo, V.; Bonanno, D.; La Rocca, P.; Longhitano, F.; Bongiovanni, D. G.; Fallica, G.; Valvo, G.
2016-10-01
The Muon Portal Project was born as a joint initiative between Italian research and industrial partners, aimed at the construction of a real-size working detector prototype to inspect the content of traveling containers by means of secondary cosmic-ray muon radiation and recognize potentially dangerous hidden materials. The tomographic image is obtained by reconstructing the incoming and outgoing muon trajectories when crossing the inspected volume, employing two tracker planes located above and below the container under inspection. In this paper, the design and development of the front-end electronics of the Muon Portal detector is presented, with particular emphasis being devoted to the photo-sensor devices detecting the scintillation light and to the read-out circuitry which is in charge of processing and digitizing the analog pulse signals. In addition, the remote control system, mechanical housing, and thermal cooling system of all structural blocks of the Muon Portal tracker are also discussed, demonstrating the effectiveness and functionality of the adopted design.
Motion effects in multistatic millimeter-wave imaging systems
NASA Astrophysics Data System (ADS)
Schiessl, Andreas; Ahmed, Sherif Sayed; Schmidt, Lorenz-Peter
2013-10-01
At airport security checkpoints, authorities are demanding improved personnel screening devices for increased security. Active mm-wave imaging systems deliver the high quality images needed for reliable automatic detection of hidden threats. As mm-wave imaging systems assume static scenarios, motion effects caused by movement of persons during the screening procedure can degrade image quality, so very short measurement time is required. Multistatic imaging array designs and fully electronic scanning in combination with digital beamforming offer short measurement time together with high resolution and high image dynamic range, which are critical parameters for imaging systems used for passenger screening. In this paper, operational principles of such systems are explained, and the performance of the imaging systems with respect to motion within the scenarios is demonstrated using mm-wave images of different test objects and standing as well as moving persons. Electronic microwave imaging systems using multistatic sparse arrays are suitable for next generation screening systems, which will support on the move screening of passengers.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-27
... Frames and Image Display Devices and Components Thereof; Notice of Institution of Investigation... United States after importation of certain digital photo frames and image display devices and components... certain digital photo frames and image display devices and components thereof that infringe one or more of...
Real-time computer treatment of THz passive device images with the high image quality
NASA Astrophysics Data System (ADS)
Trofimov, Vyacheslav A.; Trofimov, Vladislav V.
2012-06-01
We demonstrate real-time computer code improving significantly the quality of images captured by the passive THz imaging system. The code is not only designed for a THz passive device: it can be applied to any kind of such devices and active THz imaging systems as well. We applied our code for computer processing of images captured by four passive THz imaging devices manufactured by different companies. It should be stressed that computer processing of images produced by different companies requires using the different spatial filters usually. The performance of current version of the computer code is greater than one image per second for a THz image having more than 5000 pixels and 24 bit number representation. Processing of THz single image produces about 20 images simultaneously corresponding to various spatial filters. The computer code allows increasing the number of pixels for processed images without noticeable reduction of image quality. The performance of the computer code can be increased many times using parallel algorithms for processing the image. We develop original spatial filters which allow one to see objects with sizes less than 2 cm. The imagery is produced by passive THz imaging devices which captured the images of objects hidden under opaque clothes. For images with high noise we develop an approach which results in suppression of the noise after using the computer processing and we obtain the good quality image. With the aim of illustrating the efficiency of the developed approach we demonstrate the detection of the liquid explosive, ordinary explosive, knife, pistol, metal plate, CD, ceramics, chocolate and other objects hidden under opaque clothes. The results demonstrate the high efficiency of our approach for the detection of hidden objects and they are a very promising solution for the security problem.
Memory device for two-dimensional radiant energy array computers
NASA Technical Reports Server (NTRS)
Schaefer, D. H.; Strong, J. P., III (Inventor)
1977-01-01
A memory device for two dimensional radiant energy array computers was developed, in which the memory device stores digital information in an input array of radiant energy digital signals that are characterized by ordered rows and columns. The memory device contains a radiant energy logic storing device having a pair of input surface locations for receiving a pair of separate radiant energy digital signal arrays and an output surface location adapted to transmit a radiant energy digital signal array. A regenerative feedback device that couples one of the input surface locations to the output surface location in a manner for causing regenerative feedback is also included
The Hidden Formula of Youth Digital Media Engagement. Tips
ERIC Educational Resources Information Center
Reynolds, Rebecca
2009-01-01
The slate of recent reports on youth technology engagement do not explicitly address the construct of "perceived competence," the third main affective state associated with intrinsically-motivated behavior in Edward Deci and Richard Ryan's broader psychological research. In the Spring of 2008, a team of researchers at Syracuse…
Federal Register 2010, 2011, 2012, 2013, 2014
2013-03-18
... Image Display Devices and Components Thereof; Issuance of a Limited Exclusion Order and Cease and Desist... within the United States after importation of certain digital photo frames and image display devices and...: (1) The unlicensed entry of digital photo frames and image display devices and components thereof...
NASA Astrophysics Data System (ADS)
Moia, Franco
2002-04-01
With linear photo-polymerization (LPP) ROLIC has invented a photo-patternable technology enabling to align not only conventional liquid crystals but also liquid crystals polymers (LCP). ROLIC's optical security device technology derives from its LPP/LCP technology. LPP/LCP security devices are created by structured photo-alignment of an LPP layer through phot-masks, thus generating a high resolution, photo-patterned aligning layer which carries the aligning information of the image to be created. The subsequent LCP layer transforms the aligning information into an optical phase image with low and/or very high information content, such as invisible photographic pictures. The building block capability of the LPP/LCP technology allows the manufacturing of cholesteric and non-cholesteric LPP/LCP devices which cover 1st and/or 2nd level applications. Apart from black/white security devices colored information zones can be integrated. Moreover, we have developed an LPP/LCP security device which covers all three- 1st, 2nd and 3rd- inspection levels in one and the same authentication device: besides a color shift by tilting the device (1st level) and the detection of normally hidden information by use of a simple sheet polarizer (2nd level) the new device contains encrypted hidden information which can be visualized only by superimposing an LPP/LCP inspection tool (key) for decryption (3rd level). This optical key is also based on the LPP/LCP technology and is itself a 3rd level security device.
An adaptive Hidden Markov Model for activity recognition based on a wearable multi-sensor device
USDA-ARS?s Scientific Manuscript database
Human activity recognition is important in the study of personal health, wellness and lifestyle. In order to acquire human activity information from the personal space, many wearable multi-sensor devices have been developed. In this paper, a novel technique for automatic activity recognition based o...
Hidden Treasures for Science Teaching: United States Patents.
ERIC Educational Resources Information Center
Anderson, Norman D.
United States patents are a source of historical information with many implications for science teaching. Using patents as science teaching devices has been largely ignored by science educators. Some of these devices can be easily modified for use in today's classrooms; in addition, patents serve as great examples of how our knowledge of science…
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-19
... Devices and Related Software; Notice of Investigation AGENCY: U.S. International Trade Commission. ACTION... certain digital imaging devices and related software by reason of infringement of certain claims of U.S... digital imaging devices and related software that infringe one or more of claim 1-3 and 5-8 of U.S. Patent...
Analysis of the Measurement and Modeling of a Digital Inverter Based on a Ferroelectric Transistor
NASA Technical Reports Server (NTRS)
MacLeod, Todd C.; Phillips, Thomas A.; Sayyah, Rana; Ho, Fat D.
2009-01-01
The use of ferroelectric materials for digital memory devices is widely researched and implemented, but ferroelectric devices also possess unique characteristics that make them have interesting and useful properties in digital circuits. Because ferroelectric transistors possess the properties of hysteresis and nonlinearity, a digital inverter containing a FeFET has very different characteristics than one with a traditional FET. This paper characterizes the properties of the measurement and modeling of a FeFET based digital inverter. The circuit was set up using discrete FeFETs. The purpose of this circuit was not to produce a practical integrated circuit that could be inserted directly into existing digital circuits, but to explore the properties and characteristics of such a device and to look at possible future uses. Input and output characteristics are presented, as well as timing measurements. Comparisons are made between the ferroelectric device and the properties of a standard digital inverter. Potential benefits and possible uses of such a device are presented.
Learning from adverse incidents involving medical devices.
Amoore, John; Ingram, Paula
While an adverse event involving a medical device is often ascribed to either user error or device failure, the causes are typically multifactorial. A number of incidents involving medical devices are explored using this approach to investigate the various causes of the incident and the protective barriers that minimised or prevented adverse consequences. User factors, including mistakes, omissions and lack of training, conspired with background factors--device controls and device design, storage conditions, hidden device damage and physical layout of equipment when in use--to cause the adverse events. Protective barriers that prevented or minimised the consequences included staff vigilance, operating procedures and alarms.
NASA Technical Reports Server (NTRS)
Cochran, Donna J.; Kniffin, Scott D.; LaBel, Kenneth A.; OBryan, Martha V.; Reed, Robert A.; Ladbury, Ray L.; Howard, James W., Jr.; Poivey, Christian; Buchner, Stephen P.; Marshall, Cheryl J.
2004-01-01
We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to-Digital Converters (ADCs), and Digital-to-Analog Converters (DACS), among others.
NASA Technical Reports Server (NTRS)
Cochran, Donna J.; Kniffin, Scott D.; LaBel, Kenneth A.; OBryan, Martha V.; Reed, Robert A.; Ladbury, Ray L.; Howard, James W., Jr.; Poivey, Christian; Buchner, Stephen P.; Marshall, Cheryl J.
2003-01-01
We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to-Digital Converters (ADCs), and Digital-to-Analog Converters (DACs), among others.
37 CFR 201.28 - Statements of Account for digital audio recording devices or media.
Code of Federal Regulations, 2011 CFR
2011-07-01
... digital audio recording devices or media. 201.28 Section 201.28 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.28 Statements of Account for digital audio recording devices or media. (a) General. This section prescribes rules...
37 CFR 201.28 - Statements of Account for digital audio recording devices or media.
Code of Federal Regulations, 2012 CFR
2012-07-01
... digital audio recording devices or media. 201.28 Section 201.28 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.28 Statements of Account for digital audio recording devices or media. (a) General. This section prescribes rules...
37 CFR 201.28 - Statements of Account for digital audio recording devices or media.
Code of Federal Regulations, 2013 CFR
2013-07-01
... digital audio recording devices or media. 201.28 Section 201.28 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.28 Statements of Account for digital audio recording devices or media. (a) General. This section prescribes rules...
False Reality or Hidden Messages: Reading Graphs Obtained in Computerized Biological Experiments
ERIC Educational Resources Information Center
Sorgo, Andrej; Kocijancic, Slavko
2012-01-01
Information and communication technology (ICT) has become an inseparable part of schoolwork and a goal of education to prepare scientifically literate and digitally competent citizens. Yet the introduction of computers into school work has been much slower than its introduction in other spheres of life. Teachers' lack of knowledge/skills and…
Future Trends in Children's Web Pages: Probing Hidden Biases for Information Quality
ERIC Educational Resources Information Center
Kurubacak, Gulsun
2007-01-01
As global digital communication continues to flourish, Children's Web pages become more critical for children to realize not only the surface but also breadth and deeper meanings in presenting these milieus. These pages not only are very diverse and complex but also enable intense communication across social, cultural and political restrictions…
Evaluating Information Quality: Hidden Biases on the Children's Web Pages
ERIC Educational Resources Information Center
Kurubacak, Gulsun
2006-01-01
As global digital communication continues to flourish, the Children's Web pages become more critical for children to realize not only the surface but also breadth and deeper meanings in presenting these milieus. These pages not only are very diverse and complex but also enable intense communication across social, cultural and political…
Feasibility Study of Compressive Sensing Underwater Imaging Lidar
2014-03-28
Texas Instruments Digital Micromirror Devices development system. In addition, through these studies, the deficiencies and/or areas of lack...device, such as the Digital Micromirror Device (DMD), to spatially modulate the laser source that illuminates the target plane. The same binary patterns...Digital Micromirror Device (DMD) Applications," Proc. of SPIE, 2003, 4985, 14-25. [8] T. E. Giddings and J. J. Shirron, "Numerical Simulation of the
Sensors Expand the Capabilities of Robot Devices. Resources in Technology and Engineering
ERIC Educational Resources Information Center
Deal, Walter F., III; Hsiung, Steve C.
2017-01-01
Sensors of all kinds play significant roles in the way that we use and interact with technological devices today. Smartphones, household appliances, automobiles, and other products that we use every day incorporate many different kinds of sensors. While the sensors are hidden from view in the products, appliances, and tools that we use, they…
NASA Technical Reports Server (NTRS)
Cochran, Donna J.; Buchner, Stephen P.; Irwin, Tim L.; LaBel, Kenneth A.; Marshall, Cheryl J.; Reed, Robert A.; Sanders, Anthony B.; Hawkins, Donald K.; Flanigan, Ryan J.; Cox, Stephen R.
2005-01-01
We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to- Digital Converters (ADCs), and Digital-to-Analog Converters (DACs), among others. T
37 CFR 201.27 - Initial notice of distribution of digital audio recording devices or media.
Code of Federal Regulations, 2013 CFR
2013-07-01
... distribution of digital audio recording devices or media. 201.27 Section 201.27 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.27 Initial notice of distribution of digital audio recording devices or media. (a) General. This section...
37 CFR 201.27 - Initial notice of distribution of digital audio recording devices or media.
Code of Federal Regulations, 2014 CFR
2014-07-01
... distribution of digital audio recording devices or media. 201.27 Section 201.27 Patents, Trademarks, and Copyrights U.S. COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.27 Initial notice of distribution of digital audio recording devices or media. (a) General. This...
37 CFR 201.28 - Statements of Account for digital audio recording devices or media.
Code of Federal Regulations, 2014 CFR
2014-07-01
... digital audio recording devices or media. 201.28 Section 201.28 Patents, Trademarks, and Copyrights U.S. COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.28 Statements of Account for digital audio recording devices or media. (a) General. This section prescribes rules...
37 CFR 201.27 - Initial notice of distribution of digital audio recording devices or media.
Code of Federal Regulations, 2012 CFR
2012-07-01
... distribution of digital audio recording devices or media. 201.27 Section 201.27 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.27 Initial notice of distribution of digital audio recording devices or media. (a) General. This section...
37 CFR 201.27 - Initial notice of distribution of digital audio recording devices or media.
Code of Federal Regulations, 2011 CFR
2011-07-01
... distribution of digital audio recording devices or media. 201.27 Section 201.27 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.27 Initial notice of distribution of digital audio recording devices or media. (a) General. This section...
37 CFR 201.27 - Initial notice of distribution of digital audio recording devices or media.
Code of Federal Regulations, 2010 CFR
2010-07-01
... distribution of digital audio recording devices or media. 201.27 Section 201.27 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS COPYRIGHT OFFICE AND PROCEDURES GENERAL PROVISIONS § 201.27 Initial notice of distribution of digital audio recording devices or media. (a) General. This section...
Holographic quantitative imaging of sample hidden by turbid medium or occluding objects
NASA Astrophysics Data System (ADS)
Bianco, V.; Miccio, L.; Merola, F.; Memmolo, P.; Gennari, O.; Paturzo, Melania; Netti, P. A.; Ferraro, P.
2015-03-01
Digital Holography (DH) numerical procedures have been developed to allow imaging through turbid media. A fluid is considered turbid when dispersed particles provoke strong light scattering, thus destroying the image formation by any standard optical system. Here we show that sharp amplitude imaging and phase-contrast mapping of object hidden behind turbid medium and/or occluding objects are possible in harsh noise conditions and with a large field-of view by Multi-Look DH microscopy. In particular, it will be shown that both amplitude imaging and phase-contrast mapping of cells hidden behind a flow of Red Blood Cells can be obtained. This allows, in a noninvasive way, the quantitative evaluation of living processes in Lab on Chip platforms where conventional microscopy techniques fail. The combination of this technique with endoscopic imaging can pave the way for the holographic blood vessel inspection, e.g. to look for settled cholesterol plaques as well as blood clots for a rapid diagnostics of blood diseases.
Utilizing Mobile Devices to Enrich the Learning Style of Students
ERIC Educational Resources Information Center
McGovern, Enda F.; Luna-Nevarez, Cuauhtemoc; Baruca, Arne
2017-01-01
As digital technologies evolve in education, business faculty have increased access to an extensive range of mobile devices and online applications to help them inspire students' passion for learning. Adopting new digital approaches to teaching can also enhance the learning style of students who are immersed in the use of digital devices. How can…
ERIC Educational Resources Information Center
Plopper, Bruce L.; Conaway, Anne Fleming
2013-01-01
Research showing adolescents' ever-increasing use of digital devices, combined with calls from governmental officials to incorporate more technology into classroom activities, prompted this survey of Arkansas scholastic journalism advisers. The goal was to determine how they used digital communication devices in their teaching. Results showed lack…
Staudacher, Ingo; Nalpathamkalam, Asha Roy; Uhlmann, Lorenz; Illg, Claudius; Seehausen, Sebastian; Akhavanpoor, Mohammadreza; Buchauer, Anke; Geis, Nicolas; Lugenbiel, Patrick; Schweizer, Patrick A; Xynogalos, Panagiotis; Zylla, Maura M; Scholz, Eberhard; Zitron, Edgar; Katus, Hugo A; Thomas, Dierk
2017-10-11
Increasing numbers of patients with cardiovascular implantable electronic devices (CIEDs) and limited follow-up capacities highlight unmet challenges in clinical electrophysiology. Integrated software (MediConnect ® ) enabling fully digital processing of device interrogation data has been commercially developed to facilitate follow-up visits. We sought to assess feasibility of fully digital data processing (FDDP) during ambulatory device follow-up in a high-volume tertiary hospital to provide guidance for future users of FDDP software. A total of 391 patients (mean age, 70 years) presenting to the outpatient department for routine device follow-up were analyzed (pacemaker, 44%; implantable cardioverter defibrillator, 39%; cardiac resynchronization therapy device, 16%). Quality of data transfer and follow-up duration were compared between digital (n = 265) and manual processing of device data (n = 126). Digital data import was successful, complete and correct in 82% of cases when early software versions were used. When using the most recent software version the rate of successful digital data import increased to 100%. Software-based import of interrogation data was complete and without failure in 97% of cases. The mean duration of a follow-up visit did not differ between the two groups (digital 18.7 min vs. manual data transfer 18.2 min). FDDP software was successfully implemented into the ambulatory follow-up of patients with implanted pacemakers and defibrillators. Digital data import into electronic patient management software was feasible and supported the physician's workflow. The total duration of follow-up visits comprising technical device interrogation and clinical actions was not affected in the present tertiary center outpatient cohort.
Introducing Rotational Motion with EXIF Data
ERIC Educational Resources Information Center
Peterson, James
2011-01-01
In their article "Measuring the Flight Speed of Fire Bombers from Photos: An In-Class Exercise in Introductory Kinematics," Greg W. Lowe and Eric Ayars remind us that photographs have always had physics hidden in them if you look hard enough. Since digital photos are embedded with EXIF data, vastly more physics can be explored with them. EXIF…
Dividing at an Early Age: The Hidden Digital Divide in Ohio Elementary Schools
ERIC Educational Resources Information Center
Wood, Lawrence; Howley, Aimee
2012-01-01
Computers are now a ubiquitous part of US elementary school education. With policy reports suggesting that inequities in information and communication technology (ICT) access across US schools are a thing of the past, investigating how such resources and their use may nonetheless continue to vary becomes all that much more important. Through a…
Future Trends in Chlldren's Web Pages: Probing Hidden Biases for Information Quality
ERIC Educational Resources Information Center
Kurubacak, Gulsun
2007-01-01
As global digital communication continues to flourish, Children's Web pages become more critical for children to realize not only the surface but also breadth and deeper meanings in presenting these milieus. These pages not only are very diverse and complex but also enable intense communication across social, cultural and political restrictions…
For What Conditions Are Assistive Devices Used?
... walking or other movement, inability to use a computer mouse, slow response time, limited fine or gross ... people with hidden disabilities can benefit from assistive technologies for certain activities or during certain stages of ...
NASA Astrophysics Data System (ADS)
Kuznetsov, N. V.; Leonov, G. A.; Yuldashev, M. V.; Yuldashev, R. V.
2017-10-01
During recent years it has been shown that hidden oscillations, whose basin of attraction does not overlap with small neighborhoods of equilibria, may significantly complicate simulation of dynamical models, lead to unreliable results and wrong conclusions, and cause serious damage in drilling systems, aircrafts control systems, electromechanical systems, and other applications. This article provides a survey of various phase-locked loop based circuits (used in satellite navigation systems, optical, and digital communication), where such difficulties take place in MATLAB and SPICE. Considered examples can be used for testing other phase-locked loop based circuits and simulation tools, and motivate the development and application of rigorous analytical methods for the global analysis of phase-locked loop based circuits.
Look at Epilepsy: Electrical Outbursts in the Brain
... actively working to improve.” Related Stories Sound Health Robotic Device Helps Kids With Cerebral Palsy Spotlight on ... Hidden Hot Spots References The evolution of epilepsy surgery between 1991 and 2011 in nine major epilepsy ...
3D endoscopic pulsed digital holography
NASA Astrophysics Data System (ADS)
Saucedo Anaya, T.; Mendoza Santoyo, F.; Pedrini, G.; Osten, W.
2006-06-01
A rigid endoscope is used in pulsed digital holography to simultaneously evaluate the three orthogonal displacement components from hidden areas of a harmonically vibrating metallic cylinder. The cylinder is illuminated from three different illuminating directions. The optical path for each illumination direction is matched to its corresponding reference beam, but also in such a way that each object-reference beam pair optical path is mismatched such that they are incoherent and can be stored in a single CCD frame. As is typical in these types of interferometric arrangements, two digital holograms are needed in order to compare two different states of the cylinder. Each hologram is Fourier transformed and due to the incoherence introduced three separate spectra are readily identified, each belonging to a object-reference beam pair. On comparing by subtraction the phase obtained from the two pulsed digital holograms it is possible to gather quantitative 3D results from harmonic displacements.
Devices, Distractions and Digital Literacy: "Bring Your Own Device" to Polytech
ERIC Educational Resources Information Center
Drew, Leoni; Forbes, Dianne
2017-01-01
The purpose of this study is to investigate the ways polytechnic students use personal mobile devices to support their learning. This study used purposive sampling and mixed methods to generate data about student ownership and use of mobile digital devices within a single institution. Findings reveal patterns of device ownership, insights into how…
2000-01-01
second tier technologies: digital micromirror devices (DMD); alternating current gas plasma (ACGP); inorganic electroluminescent (EL, TFEL, AMEL... Micromirror Device (DMD) - Alternating Current Gas Plasma (ACGP) - Electroluminescent (EL, TFEL, AMEL) - Vacuum Fluorescent Display (VFD) - Inorganic Light...Instruments Digital Micromirror Device (DMD) Digital Light Processing technology and another, the Qualcomm/Hughes-JVC CRT/Liquid Crystal Light Valve
ERIC Educational Resources Information Center
Park, Sora; Burford, Sally
2013-01-01
This study examined whether gaining access to a new digital device enhanced the digital media literacy of young adults and what factors determine such change. Thirty-five young adults were given a mobile tablet device and observed for one year. Participants engaged in an online community, responding regularly to online surveys and discussion…
Digital Dental Photography: A Contemporary Revolution
Bumb, Dipika
2013-01-01
ABSTRACT Introduction: Photographs are symbolic of memories and with the advent of digital photography it has become much easier to collect them in a second in a more comprehensive and qualitative manner. Technological advancements in the field of digital photography have revolutionized the concept of photography as a powerful medium of expression and communication. It also offers a spectrum of perception, interpretation and execution. Photography and dentistry go hand in hand for revelation of the hidden and overlooked defects in teeth and other parts of the cavity. This article emphasizes on the significance of digital photography in dentistry and guidelines for capturing orofacial structures and radiographs in a more accurate and informative manner. Conclusion: Dental world constitutes of microstructures that have to be recorded in a detailed manner in order to perform patient education, documentation of records and treatment, illustration of lectures, publication and web connectivity of complicated cases. How to cite this article: Desai V, Bumb D. Digital Dental Photography: A Contemporary Revolution. Int J Clin Pediatr Dent 2013;6(3):193-196. PMID:25206221
Digital dental photography: a contemporary revolution.
Desai, Vela; Bumb, Dipika
2013-09-01
Photographs are symbolic of memories and with the advent of digital photography it has become much easier to collect them in a second in a more comprehensive and qualitative manner. Technological advancements in the field of digital photography have revolutionized the concept of photography as a powerful medium of expression and communication. It also offers a spectrum of perception, interpretation and execution. Photography and dentistry go hand in hand for revelation of the hidden and overlooked defects in teeth and other parts of the cavity. This article emphasizes on the significance of digital photography in dentistry and guidelines for capturing orofacial structures and radiographs in a more accurate and informative manner. Dental world constitutes of microstructures that have to be recorded in a detailed manner in order to perform patient education, documentation of records and treatment, illustration of lectures, publication and web connectivity of complicated cases. How to cite this article: Desai V, Bumb D. Digital Dental Photography: A Contemporary Revolution. Int J Clin Pediatr Dent 2013;6(3):193-196.
Visualization of stress wave propagation via air-coupled acoustic emission sensors
NASA Astrophysics Data System (ADS)
Rivey, Joshua C.; Lee, Gil-Yong; Yang, Jinkyu; Kim, Youngkey; Kim, Sungchan
2017-02-01
We experimentally demonstrate the feasibility of visualizing stress waves propagating in plates using air-coupled acoustic emission sensors. Specifically, we employ a device that embeds arrays of microphones around an optical lens in a helical pattern. By implementing a beamforming technique, this remote sensing system allows us to record wave propagation events in situ via a single-shot and full-field measurement. This is a significant improvement over the conventional wave propagation tracking approaches based on laser doppler vibrometry or digital image correlation techniques. In this paper, we focus on demonstrating the feasibility and efficacy of this air-coupled acoustic emission technique by using large metallic plates exposed to external impacts. The visualization results of stress wave propagation will be shown under various impact scenarios. The proposed technique can be used to characterize and localize damage by detecting the attenuation, reflection, and scattering of stress waves that occurs at damage locations. This can ultimately lead to the development of new structural health monitoring and nondestructive evaluation methods for identifying hidden cracks or delaminations in metallic or composite plate structures, simultaneously negating the need for mounted contact sensors.
Computer-generated holograms and diffraction gratings in optical security applications
NASA Astrophysics Data System (ADS)
Stepien, Pawel J.
2000-04-01
The term 'computer generated hologram' (CGH) describes a diffractive structure strictly calculated and recorded to diffract light in a desired way. The CGH surface profile is a result of the wavefront calculation rather than of interference. CGHs are able to form 2D and 3D images. Optically, variable devices (OVDs) composed of diffractive gratings are often used in security applications. There are various types of optically and digitally recorded gratings in security applications. Grating based OVDs are used to record bright 2D images with limited range of cinematic effects. These effects result form various orientations or densities of recorded gratings. It is difficult to record high quality OVDs of 3D objects using gratings. Stereo grams and analogue rainbow holograms offer 3D imaging, but they are darker and have lower resolution than grating OVDs. CGH based OVDs contains unlimited range of cinematic effects and high quality 3D images. Images recorded using CGHs are usually more noisy than grating based OVDs, because of numerical inaccuracies in CGH calculation and mastering. CGH based OVDs enable smooth integration of hidden and machine- readable features within an OVD design.
ERIC Educational Resources Information Center
Palaiologou, Ioanna
2016-01-01
A body of research is emerging on early childhood education teachers' views on the integration of digital technologies in their practice. Despite evidence of the digitalisation of homes in affluent societies and children's interactions in highly mediated digital environments, few teachers so far have integrated digital devices into a play-based…
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor); Konz, Daniel W. (Inventor); Winkelmann, Joseph P. (Inventor)
2005-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is then converted by the network device interface into digital signals and transmitted back to the controller. In one advantageous embodiment, the network device interface uses a specialized protocol for communicating across the network bus that uses a low-level instruction set and has low overhead for data communication.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Ellerbrock, Philip J. (Inventor); Winkelmann, Joseph P. (Inventor); Grant, Robert L. (Inventor); Konz, Daniel W. (Inventor)
2006-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is then converted by the network device interface into digital signals and transmitted back to the controller. In one advantageous embodiment, the network device interface is a state machine, such as an ASIC, that operates independent of a processor in communicating with the bus controller and data channels.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Ellerbrock, Philip J. (Inventor); Konz, Daniel W. (Inventor); Winkelmann, Joseph P. (Inventor); Grant, Robert L. (Inventor)
2004-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is then converted by the network device interface into digital signals and transmitted back to the controller. In one advantageous embodiment, the network device interface uses a specialized protocol for communicating across the network bus that uses a low-level instruction set and has low overhead for data communication.
Two-dimensional radiant energy array computers and computing devices
NASA Technical Reports Server (NTRS)
Schaefer, D. H.; Strong, J. P., III (Inventor)
1976-01-01
Two dimensional digital computers and computer devices operate in parallel on rectangular arrays of digital radiant energy optical signal elements which are arranged in ordered rows and columns. Logic gate devices receive two input arrays and provide an output array having digital states dependent only on the digital states of the signal elements of the two input arrays at corresponding row and column positions. The logic devices include an array of photoconductors responsive to at least one of the input arrays for either selectively accelerating electrons to a phosphor output surface, applying potentials to an electroluminescent output layer, exciting an array of discrete radiant energy sources, or exciting a liquid crystal to influence crystal transparency or reflectivity.
Digital Mammography with a Mosaic of CCD-Arrays
NASA Technical Reports Server (NTRS)
Jalink, Antony, Jr. (Inventor); McAdoo, James A. (Inventor)
1996-01-01
The present invention relates generally to a mammography device and method and more particularly to a novel digital mammography device and method to detect microcalcifications of precancerous tissue. A digital mammography device uses a mosaic of electronic digital imaging arrays to scan an x-ray image. The mosaic of arrays is repositioned several times to expose different portions of the image, until the entire image is scanned. The data generated by the arrays during each exposure is stored in a computer. After the final exposure, the computer combines data of the several partial images to produce a composite of the original x-ray image. An aperture plate is used to reduce scatter and the overall exposure of the patient to x-rays. The novelty of this invention is that it provides a digital mammography device with large field coverage, high spatial resolution, scatter rejection, excellent contrast characteristics and lesion detectability under clinical conditions. This device also shields the patient from excessive radiation, can detect extremely small calcifications and allows manipulation and storage of the image.
Short range, ultra-wideband radar with high resolution swept range gate
McEwan, T.E.
1998-05-26
A radar range finder and hidden object locator is based on ultra-wide band radar with a high resolution swept range gate. The device generates an equivalent time amplitude scan with a typical range of 4 inches to 20 feet, and an analog range resolution as limited by a jitter of on the order of 0.01 inches. A differential sampling receiver is employed to effectively eliminate ringing and other aberrations induced in the receiver by the near proximity of the transmit antenna, so a background subtraction is not needed, simplifying the circuitry while improving performance. Uses of the invention include a replacement of ultrasound devices for fluid level sensing, automotive radar, such as cruise control and parking assistance, hidden object location, such as stud and rebar finding. Also, this technology can be used when positioned over a highway lane to collect vehicle count and speed data for traffic control. 14 figs.
Short range, ultra-wideband radar with high resolution swept range gate
McEwan, Thomas E.
1998-05-26
A radar range finder and hidden object locator is based on ultra-wide band radar with a high resolution swept range gate. The device generates an equivalent time amplitude scan with a typical range of 4 inches to 20 feet, and an analog range resolution as limited by a jitter of on the order of 0.01 inches. A differential sampling receiver is employed to effectively eliminate ringing and other aberrations induced in the receiver by the near proximity of the transmit antenna, so a background subtraction is not needed, simplifying the circuitry while improving performance. Uses of the invention include a replacement of ultrasound devices for fluid level sensing, automotive radar, such as cruise control and parking assistance, hidden object location, such as stud and rebar finding. Also, this technology can be used when positioned over a highway lane to collect vehicle count and speed data for traffic control.
Exposing Vital Forensic Artifacts of USB Devices in the Windows 10 Registry
2015-06-01
12b. DISTRIBUTION CODE 13. ABSTRACT (maximum 200 words) Digital media devices are regularly seized pursuant to criminal investigations and...ABSTRACT Digital media devices are regularly seized pursuant to criminal investigations and Microsoft Windows is the most commonly encountered... digital footprints available on seized computers that assist in re-creating a crime scene and telling the story of the events that occurred. Part of this
Advanced Relay Design and Technology for Energy-Efficient Electronics
2011-07-07
Estimates and Unique Failure Mechanisms of the Digital Micromirror Device (DMD),” in Proceedings of the IEEE Annual International Reliability Physics...Symposium (IRPS ), pp. 9-16, March 1998. [18] A. B. Sontheimer, “Digital Micromirror Device (DMD) Hinge Memory Lifetime Reliability Modeling,” in...Mechanisms of the Digital Micromirror Device (DMD),” in Proceedings of the IEEE Annual International Reliability Physics Symposium (IRPS ), pp. 9-16
Integrated Real-Time Control and Imaging System for Microbiorobotics and Nanobiostructures
2016-01-11
kit with a control board and ALP 4.1 basic controller suite. The digital micromirror device is the highest resolution 16:9 aspect ratio system. This...in Figure 1, consisted of the following: (1) digital micromirror device (DMD) and controller, (2) an inverted epifluorescence microscope with a flat...accompanying control board and ALP 4.1 basic controller suite. The digital micromirror device is currently the highest commercially available
Multispectral THz-VIS passive imaging system for hidden threats visualization
NASA Astrophysics Data System (ADS)
Kowalski, Marcin; Palka, Norbert; Szustakowski, Mieczyslaw
2013-10-01
Terahertz imaging, is the latest entry into the crowded field of imaging technologies. Many applications are emerging for the relatively new technology. THz radiation penetrates deep into nonpolar and nonmetallic materials such as paper, plastic, clothes, wood, and ceramics that are usually opaque at optical wavelengths. The T-rays have large potential in the field of hidden objects detection because it is not harmful to humans. The main difficulty in the THz imaging systems is low image quality thus it is justified to combine THz images with the high-resolution images from a visible camera. An imaging system is usually composed of various subsystems. Many of the imaging systems use imaging devices working in various spectral ranges. Our goal is to build a system harmless to humans for screening and detection of hidden objects using a THz and VIS cameras.
Meng, Xi; Nguyen, Bao D; Ridge, Clark; Shaka, A J
2009-01-01
High-dimensional (HD) NMR spectra have poorer digital resolution than low-dimensional (LD) spectra, for a fixed amount of experiment time. This has led to "reduced-dimensionality" strategies, in which several LD projections of the HD NMR spectrum are acquired, each with higher digital resolution; an approximate HD spectrum is then inferred by some means. We propose a strategy that moves in the opposite direction, by adding more time dimensions to increase the information content of the data set, even if only a very sparse time grid is used in each dimension. The full HD time-domain data can be analyzed by the filter diagonalization method (FDM), yielding very narrow resonances along all of the frequency axes, even those with sparse sampling. Integrating over the added dimensions of HD FDM NMR spectra reconstitutes LD spectra with enhanced resolution, often more quickly than direct acquisition of the LD spectrum with a larger number of grid points in each of the fewer dimensions. If the extra-dimensions do not appear in the final spectrum, and are used solely to boost information content, we propose the moniker hidden-dimension NMR. This work shows that HD peaks have unmistakable frequency signatures that can be detected as single HD objects by an appropriate algorithm, even though their patterns would be tricky for a human operator to visualize or recognize, and even if digital resolution in an HD FT spectrum is very coarse compared with natural line widths.
Cherepy, Nerine Jane; Payne, Stephen Anthony; Drury, Owen B.; Sturm, Benjamin W.
2016-02-09
According to one embodiment, a scintillator radiation detector system includes a scintillator, and a processing device for processing pulse traces corresponding to light pulses from the scintillator, where the processing device is configured to: process each pulse trace over at least two temporal windows and to use pulse digitization to improve energy resolution of the system. According to another embodiment, a scintillator radiation detector system includes a processing device configured to: fit digitized scintillation waveforms to an algorithm, perform a direct integration of fit parameters, process multiple integration windows for each digitized scintillation waveform to determine a correction factor, and apply the correction factor to each digitized scintillation waveform.
78 FR 36478 - Accessibility of User Interfaces, and Video Programming Guides and Menus
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-18
... equipment: ``digital apparatus'' and ``navigation devices.'' Specifically, section 204 applies to ``digital... apparatus, including equipment purchased at retail by a consumer to access video programming, would be..., and video programming guides, and menus provided by digital apparatus and navigation devices are...
A wavelet domain adaptive image watermarking method based on chaotic encryption
NASA Astrophysics Data System (ADS)
Wei, Fang; Liu, Jian; Cao, Hanqiang; Yang, Jun
2009-10-01
A digital watermarking technique is a specific branch of steganography, which can be used in various applications, provides a novel way to solve security problems for multimedia information. In this paper, we proposed a kind of wavelet domain adaptive image digital watermarking method using chaotic stream encrypt and human eye visual property. The secret information that can be seen as a watermarking is hidden into a host image, which can be publicly accessed, so the transportation of the secret information will not attract the attention of illegal receiver. The experimental results show that the method is invisible and robust against some image processing.
NASA Astrophysics Data System (ADS)
An, Yun-Kyu; Song, Homin; Sohn, Hoon
2014-09-01
This paper presents a wireless ultrasonic wavefield imaging (WUWI) technique for detecting hidden damage inside a steel box girder bridge. The proposed technique allows (1) complete wireless excitation of piezoelectric transducers and noncontact sensing of the corresponding responses using laser beams, (2) autonomous damage visualization without comparing against baseline data previously accumulated from the pristine condition of a target structure and (3) robust damage diagnosis even for real structures with complex structural geometries. First, a new WUWI hardware system was developed by integrating optoelectronic-based signal transmitting and receiving devices and a scanning laser Doppler vibrometer. Next, a damage visualization algorithm, self-referencing f-k filter (SRF), was introduced to isolate and visualize only crack-induced ultrasonic modes from measured ultrasonic wavefield images. Finally, the performance of the proposed technique was validated through hidden crack visualization at a decommissioned Ramp-G Bridge in South Korea. The experimental results reveal that the proposed technique instantaneously detects and successfully visualizes hidden cracks even in the complex structure of a real bridge.
Study on the system-level test method of digital metering in smart substation
NASA Astrophysics Data System (ADS)
Zhang, Xiang; Yang, Min; Hu, Juan; Li, Fuchao; Luo, Ruixi; Li, Jinsong; Ai, Bing
2017-03-01
Nowadays, the test methods of digital metering system in smart substation are used to test and evaluate the performance of a single device, but these methods can only effectively guarantee the accuracy and reliability of the measurement results of a digital metering device in a single run, it does not completely reflect the performance when each device constitutes a complete system. This paper introduced the shortages of the existing test methods. A system-level test method of digital metering in smart substation was proposed, and the feasibility of the method was proved by the actual test.
Bring Your Own Device or Bring Your Own Distraction
ERIC Educational Resources Information Center
Laxman, Kumar; Holt, Craig
2017-01-01
The purpose of this exploratory case study was to investigate the utilisation of Bring Your Own Device (BYOD) technologies in the classroom to determine if students and teachers perceive that the use of a digital device increased a learner's access to learning opportunities within the classroom, and, if the use of digital devices increased their…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-11-16
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-796] Certain Electronic Digital Media... electronic digital media devices and components thereof imported by respondents Samsung Electronics Co, Ltd... Samsung. FOR FURTHER INFORMATION CONTACT: Cathy Chen, Office of the General Counsel, U.S. International...
Curbing Digital Distractions in the Classroom
ERIC Educational Resources Information Center
Seemiller, Corey
2017-01-01
Whether banking, communicating, watching television, or shopping, people can now do nearly anything on their personal digital devices. This digital access even extends to the college classroom where students use their personal devices for a multitude of non-class related purposes. Findings from a survey of 193 college undergraduates found that…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-13
... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-807] Certain Digital Photo Frames and Image Display Devices and Components Thereof; Commission Determination Not To Review an Initial... importation, and the sale within the United States after importation of certain digital photo frames and image...
Mobile technology and the digitization of healthcare
Bhavnani, Sanjeev P.; Narula, Jagat; Sengupta, Partho P.
2016-01-01
The convergence of science and technology in our dynamic digital era has resulted in the development of innovative digital health devices that allow easy and accurate characterization in health and disease. Technological advancements and the miniaturization of diagnostic instruments to modern smartphone-connected and mobile health (mHealth) devices such as the iECG, handheld ultrasound, and lab-on-a-chip technologies have led to increasing enthusiasm for patient care with promises to decrease healthcare costs and to improve outcomes. This ‘hype’ for mHealth has recently intersected with the ‘real world’ and is providing important insights into how patients and practitioners are utilizing digital health technologies. It is also raising important questions regarding the evidence supporting widespread device use. In this state-of-the-art review, we assess the current literature of mHealth and aim to provide a framework for the advances in mHealth by understanding the various device, patient, and clinical factors as they relate to digital health from device designs and patient engagement, to clinical workflow and device regulation. We also outline new strategies for generation and analysis of mHealth data at the individual and population-based levels. PMID:26873093
Harvey, Scott D [Kennewick, WA
2011-06-21
A process and sensor device are disclosed that employ metal .beta.-diketonate polymers to selectively capture gas-phase explosives and weaponized chemical agents in a sampling area or volume. The metal .beta.-diketonate polymers can be applied to surfaces in various analytical formats for detection of: improvised explosive devices, unexploded ordinance, munitions hidden in cargo holds, explosives, and chemical weapons in public areas.
Detection of latent fingerprint hidden beneath adhesive tape by optical coherence tomography.
Zhang, Ning; Wang, Chengming; Sun, Zhenwen; Li, Zhigang; Xie, Lanchi; Yan, Yuwen; Xu, Lei; Guo, Jingjing; Huang, Wei; Li, Zhihui; Xue, Jing; Liu, Huan; Xu, Xiaojing
2018-06-01
Adhesive tape is one type of common item which can be encountered in criminal cases involving rape, murder, kidnapping and explosives. It is often the case that a suspect deposits latent fingerprints on the sticky side of adhesive tape material when tying up victims, manufacturing improvised explosive devices or packaging illegal goods. However, the adhesive tapes found at crime scenes are usually stuck together or attached to a certain substrate, and thus the latent fingerprints may be hidden beneath the tapes. Current methods to detect latent fingerprint hidden beneath adhesive tape need to peel it off first and then apply physical or chemical methods to develop the fingerprint, which undergo complicated procedures and would affect the original condition of latent print. Optical coherence tomography (OCT) is a novel applied techniques in forensics which enables obtaining cross-sectional structure with the advantages of non-invasive, in-situ, high resolution and high speed. In this paper, a custom-built spectral-domain OCT (SD-OCT) system with a hand-held probe was employed to detect fingerprints hidden beneath different types of adhesive tapes. Three-dimensional (3D) OCT reconstructions were performed and the en face images were presented to reveal the hidden fingerprints. The results demonstrate that OCT is a promising tool for rapidly detecting and recovering high quality image of latent fingerprint hidden beneath adhesive tape without any changes to the original state and preserve the integrity of the evidence. Copyright © 2018 Elsevier B.V. All rights reserved.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Konz, Daniel W. (Inventor); Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor); Winkelmann, Joseph P. (Inventor)
2006-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is then converted into digital signals and transmitted back to the controller. In one embodiment, the bus controller sends commands and data a defined bit rate, and the network device interface senses this bit rate and sends data back to the bus controller using the defined bit rate.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Konz, Daniel W. (Inventor); Winkelmann, Joseph P. (Inventor); Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor)
2007-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is converted into digital signals and transmitted to the controller. In some embodiments, network device interfaces associated with different data channels coordinate communications with the other interfaces based on either a transition in a command message sent by the bus controller or a synchronous clock signal.
McDonnell, Mark D.; Tissera, Migel D.; Vladusich, Tony; van Schaik, André; Tapson, Jonathan
2015-01-01
Recent advances in training deep (multi-layer) architectures have inspired a renaissance in neural network use. For example, deep convolutional networks are becoming the default option for difficult tasks on large datasets, such as image and speech recognition. However, here we show that error rates below 1% on the MNIST handwritten digit benchmark can be replicated with shallow non-convolutional neural networks. This is achieved by training such networks using the ‘Extreme Learning Machine’ (ELM) approach, which also enables a very rapid training time (∼ 10 minutes). Adding distortions, as is common practise for MNIST, reduces error rates even further. Our methods are also shown to be capable of achieving less than 5.5% error rates on the NORB image database. To achieve these results, we introduce several enhancements to the standard ELM algorithm, which individually and in combination can significantly improve performance. The main innovation is to ensure each hidden-unit operates only on a randomly sized and positioned patch of each image. This form of random ‘receptive field’ sampling of the input ensures the input weight matrix is sparse, with about 90% of weights equal to zero. Furthermore, combining our methods with a small number of iterations of a single-batch backpropagation method can significantly reduce the number of hidden-units required to achieve a particular performance. Our close to state-of-the-art results for MNIST and NORB suggest that the ease of use and accuracy of the ELM algorithm for designing a single-hidden-layer neural network classifier should cause it to be given greater consideration either as a standalone method for simpler problems, or as the final classification stage in deep neural networks applied to more difficult problems. PMID:26262687
Mobile Learning Devices. Essentials for Principals
ERIC Educational Resources Information Center
Rogers, Kipp D.
2011-01-01
In "Mobile Learning Devices," the author helps educators confront and overcome their fears and doubts about using mobile learning devices (MLDs) such as cell phones, personal digital assistants, MP3 players, handheld games, digital audio players, and laptops in classrooms. School policies that ban such tools are outdated, the author suggests;…
1991-03-31
I AD-A232 768 I Annual Report Analysis of Polarizing Optical Systems for Digital Optical Computing with I ’ Symmetric Self Electrooptic Devices I To...TTU AND SuSiIU S. PUNDIN mUMBERS Polarizing Optical Systems for Digital Optical Computing with Symmetric Self Electrooptic Devices AFOSR-89-0542 C...UTION COO$ UNLIMITED 13. ABSTRACT (MAxnum00woUw Two architectural approaches have dominated the field of optical computing . The first appAch uses
Butler, Kenneth R; Minor, Deborah S; Benghuzzi, Hamed A; Tucci, Michelle
2010-01-01
The objective of this study was to evaluate terminal digit preference in blood pressure (BP) measurements taken from a sample of clinics at a large academic health sciences center. We hypothesized that terminal digit preference would occur more frequently in BP measurements taken with manual mercury sphygmomanometry compared to those obtained with semi-automated instruments. A total of 1,393 BP measures were obtained in 16 ambulatory and inpatient sites by personnel using both mercury (n=1,286) and semi-automated (n=107) devices For the semi-automated devices, a trained observer repeated the patients BP following American Heart Association recommendations using a similar device with a known calibration history. At least two recorded systolic and diastolic blood pressures (average of two or more readings for each) were obtained for all manual mercury readings. Data were evaluated using descriptive statistics and Chi square as appropriate (SPSS software, 17.0). Overall, zero and other terminal digit preference was observed more frequently in systolic (?2 = 883.21, df = 9, p < 0.001) and diastolic readings (?2 = 1076.77, df = 9, p < 0.001) from manual instruments, while all end digits obtained by clinic staff using semi-automated devices were more evenly distributed (?2 = 8.23, df = 9, p = 0.511 for systolic and ?2 = 10.48, df = 9, p = 0.313 for diastolic). In addition to zero digit bias in mercury readings, even numbers were reported with significantly higher frequency than odd numbers. There was no detectable digit preference observed when examining semi-automated measurements by clinic staff or device type for either systolic or diastolic BP measures. These findings demonstrate that terminal digit preference was more likely to occur with manual mercury sphygmomanometry. This phenomenon was most likely the result of mercury column graduation in 2 mm Hg increments producing a higher than expected frequency of even digits.
Finger-Powered Electro-Digital-Microfluidics.
Peng, Cheng; Ju, Y Sungtaek
2017-01-01
Portable microfluidic devices are promising for point-of-care (POC) diagnosis and bio- and environmental surveillance in resource-constrained or non-laboratory environments. Lateral-flow devices, some built off paper or strings, have been widely developed but the fixed layouts of their underlying wicking/microchannel structures limit their flexibility and present challenges in implementing multistep reactions. Digital microfluidics can circumvent these difficulties by addressing discrete droplets individually. Existing approaches to digital microfluidics, however, often require bulky power supplies/batteries and high voltage circuits. We present a scheme to drive digital microfluidic devices by converting mechanical energy of human fingers to electrical energy using an array of piezoelectric elements. We describe the integration our scheme into two promising digital microfluidics platforms: one based on the electro-wetting-on-dielectric (EWOD) phenomenon and the other on the electrophoretic control of droplet (EPD). Basic operations of droplet manipulations, such as droplet transport, merging and splitting, are demonstrated using the finger-powered digital-microfluidics.
Dental hygiene participation in managing incipient and hidden caries.
Barnes, Caren M
2005-10-01
With the advent of new caries detection devices that allow early detection, dental hygienists can intervene in the demineralization process and work with the patient toward remineralization through patient self-care procedures and the professional application of topical fluorides. The focus of this article is on caries detection devices, caries risk assessment, agents used to prevent dental caries, and the development of self-care plans for patients that include prevention, intervention, and therapeutic components.
Printed products for digital cameras and mobile devices
NASA Astrophysics Data System (ADS)
Fageth, Reiner; Schmidt-Sacht, Wulf
2005-01-01
Digital photography is no longer simply a successor to film. The digital market is now driven by additional devices such as mobile phones with camera and video functions (camphones) as well as innovative products derived from digital files. A large number of consumers do not print their images and non-printing has become the major enemy of wholesale printers, home printing suppliers and retailers. This paper addresses the challenge facing our industry, namely how to encourage the consumer to print images easily and conveniently from all types of digital media.
Mobile technology and the digitization of healthcare.
Bhavnani, Sanjeev P; Narula, Jagat; Sengupta, Partho P
2016-05-07
The convergence of science and technology in our dynamic digital era has resulted in the development of innovative digital health devices that allow easy and accurate characterization in health and disease. Technological advancements and the miniaturization of diagnostic instruments to modern smartphone-connected and mobile health (mHealth) devices such as the iECG, handheld ultrasound, and lab-on-a-chip technologies have led to increasing enthusiasm for patient care with promises to decrease healthcare costs and to improve outcomes. This 'hype' for mHealth has recently intersected with the 'real world' and is providing important insights into how patients and practitioners are utilizing digital health technologies. It is also raising important questions regarding the evidence supporting widespread device use. In this state-of-the-art review, we assess the current literature of mHealth and aim to provide a framework for the advances in mHealth by understanding the various device, patient, and clinical factors as they relate to digital health from device designs and patient engagement, to clinical workflow and device regulation. We also outline new strategies for generation and analysis of mHealth data at the individual and population-based levels. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.
A Stochastic Framework for Evaluating Seizure Prediction Algorithms Using Hidden Markov Models
Wong, Stephen; Gardner, Andrew B.; Krieger, Abba M.; Litt, Brian
2007-01-01
Responsive, implantable stimulation devices to treat epilepsy are now in clinical trials. New evidence suggests that these devices may be more effective when they deliver therapy before seizure onset. Despite years of effort, prospective seizure prediction, which could improve device performance, remains elusive. In large part, this is explained by lack of agreement on a statistical framework for modeling seizure generation and a method for validating algorithm performance. We present a novel stochastic framework based on a three-state hidden Markov model (HMM) (representing interictal, preictal, and seizure states) with the feature that periods of increased seizure probability can transition back to the interictal state. This notion reflects clinical experience and may enhance interpretation of published seizure prediction studies. Our model accommodates clipped EEG segments and formalizes intuitive notions regarding statistical validation. We derive equations for type I and type II errors as a function of the number of seizures, duration of interictal data, and prediction horizon length and we demonstrate the model’s utility with a novel seizure detection algorithm that appeared to predicted seizure onset. We propose this framework as a vital tool for designing and validating prediction algorithms and for facilitating collaborative research in this area. PMID:17021032
Recent Radiation Damage and Single Event Effect Results for Candidate Spacecraft Electronics
NASA Technical Reports Server (NTRS)
OBryan, Martha V.; LaBel, Kenneth A.; Reed, Robert A.; Ladbury, Ray L.; Howard, James W., Jr.; Buchner, Stephen P.; Barth, Janet L.; Kniffen, Scott D.; Seidleck, Christina M.; Marshall, Cheryl J.;
2001-01-01
We present data on the vulnerability of a variety of candidate spacecraft electronics to proton and heavy-ion induced single-event effects and proton-induced damage. Devices tested include optoelectronics, digital, analog, linear bipolar, hybrid devices, Analog-to-Digital Converters (ADCs), Digital-to-Analog Converters (DACs), and DC-DC converters, among others.
Current Single Event Effects and Radiation Damage Results for Candidate Spacecraft Electronics
NASA Technical Reports Server (NTRS)
OBryan, Martha V.; LaBel, Kenneth A.; Reed, Robert A.; Ladbury, Ray L.; Howard, James W., Jr.; Kniffin, Scott D.; Poivey, Christian; Buchner, Stephen P.; Bings, John P.; Titus, Jeff L.
2002-01-01
We present data on the vulnerability of a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects, total ionizing dose and proton-induced damage. Devices tested include optoelectronics, digital, analog, linear bipolar, hybrid devices, Analog-to-Digital Converters (ADCs), Digital-to-Analog Converters (DACs), and DC-DC converters, among others.
Fabrication and test of digital output interface devices for gas turbine electronic controls
NASA Technical Reports Server (NTRS)
Newirth, D. M.; Koenig, E. W.
1978-01-01
A program was conducted to develop an innovative digital output interface device, a digital effector with optical feedback of the fuel metering valve position, for future electronic controls for gas turbine engines. A digital effector (on-off solenoids driven directly by on-off signals from a digital electronic controller) with optical position feedback was fabricated, coupled with the fuel metering valve, and tested under simulated engine operating conditions. The testing indicated that a digital effector with optical position feedback is a suitable candidate, with proper development for future digital electronic gas turbine controls. The testing also identified several problem areas which would have to be overcome in a final production configuration.
Aita-Holmes, Cynthia; Liacouras, Peter; Wilson, William O; Grant, Gerald T
2015-08-01
An extraoral device was fabricated to assist a clarinet player with Bell's palsy. The device was fabricated by using stereophotogrammetry, digital design, and additive manufacturing technologies. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Small Form Factor Information Storage Devices for Mobile Applications in Korea
NASA Astrophysics Data System (ADS)
Park, Young-Pil; Park, No-Cheol; Kim, Chul-Jin
Recently, the ubiquitous environment in which anybody can reach a lot of information data without any limitations on the place and time has become an important social issue. There are two basic requirements in the field of information storage devices which have to be satisfied; the first is the demand for the improvement of memory capacity to manage the increased data capacity in personal and official purposes. The second is the demand for new development of information storage devices small enough to be applied to mobile multimedia digital electronics, including digital camera, PDA and mobile phones. To summarize, for the sake of mobile applications, it is necessary to develop information storage devices which have simultaneously a large capacity and a small size. Korea possesses the necessary infrastructure for developing such small sized information storage devices. It has a good digital market, major digital companies, and various research institutes. Nowadays, many companies and research institutes including university cooperate together in the research on small sized information storage devices. Thus, it is expected that small form factor optical disk drives will be commercialized in the very near future in Korea.
Information Hiding: an Annotated Bibliography
1999-04-13
parameters needed for reconstruction are enciphered using DES . The encrypted image is hidden in a cover image . [153] 074115, ‘Watermarking algorithm ...authors present a block based watermarking algorithm for digital images . The D.C.T. of the block is increased by a certain value. Quality control is...includes evaluation of the watermark robustness and the subjec- tive visual image quality. Two algorithms use the frequency domain while the two others use
Detecting 2LSB steganography using extended pairs of values analysis
NASA Astrophysics Data System (ADS)
Khalind, Omed; Aziz, Benjamin
2014-05-01
In this paper, we propose an extended pairs of values analysis to detect and estimate the amount of secret messages embedded with 2LSB replacement in digital images based on chi-square attack and regularity rate in pixel values. The detection process is separated from the estimation of the hidden message length, as it is the main requirement of any steganalysis method. Hence, the detection process acts as a discrete classifier, which classifies a given set of images into stego and clean classes. The method can accurately detect 2LSB replacement even when the message length is about 10% of the total capacity, it also reaches its best performance with an accuracy of higher than 0.96 and a true positive rate of more than 0.997 when the amount of data are 20% to 100% of the total capacity. However, the method puts no assumptions neither on the image nor the secret message, as it tested with two sets of 3000 images, compressed and uncompressed, embedded with a random message for each case. This method of detection could also be used as an automated tool to analyse a bulk of images for hidden contents, which could be used by digital forensics analysts in their investigation process.
Implementation of Adaptive Digital Controllers on Programmable Logic Devices
NASA Technical Reports Server (NTRS)
Gwaltney, David A.; King, Kenneth D.; Smith, Keary J.; Montenegro, Justino (Technical Monitor)
2002-01-01
Much has been made of the capabilities of Field Programmable Gate Arrays (FPGA's) in the hardware implementation of fast digital signal processing functions. Such capability also makes an FPGA a suitable platform for the digital implementation of closed loop controllers. Other researchers have implemented a variety of closed-loop digital controllers on FPGA's. Some of these controllers include the widely used Proportional-Integral-Derivative (PID) controller, state space controllers, neural network and fuzzy logic based controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM- based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance requirements in a compact form-factor. Generally, a software implementation on a Digital Signal Processor (DSP) device or microcontroller is used to implement digital controllers. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using DSP devices. While small form factor, commercial DSP devices are now available with event capture, data conversion, Pulse Width Modulated (PWM) outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. In general, very few DSP devices are produced that are designed to meet any level of radiation tolerance or hardness. An alternative is required for compact implementation of such functionality to withstand the harsh environment encountered on spacemap. The goal of this effort is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive-control algorithm approaches. Radiation tolerant FPGA's are a feasible option for reaching this goal.
NASA Astrophysics Data System (ADS)
Fischer, R.; Müller, R.
1989-08-01
It is shown that nonlinear optical devices are the most promising elements for an optical digital supercomputer. The basic characteristics of various developed nonlinear elements are presented, including bistable Fabry-Perot etalons, interference filters, self-electrooptic effect devices, quantum-well devices utilizing transitions between the lowest electron states in the conduction band of GaAs, etc.
Integrated digital metamaterials enables ultra-compact optical diodes
Shen, Bing; Polson, Randy; Menon, Rajesh
2015-01-01
We applied nonlinear optimization to design integrated digital metamaterials in silicon for unidirectional energy flow. Two devices, one for each polarization state, were designed, fabricated, and characterized. Both devices offer comparable or higher transmission efficiencies and extinction ratios, are easier to fabricate, exhibit larger bandwidths and are more tolerant to fabrication errors, when compared to alternatives. Furthermore, each device footprint is only 3μm × 3μm, which is the smallest optical diode ever reported. To illustrate the versatility of digital metamaterials, we also designed a polarization-independent optical diode.
2009-02-19
magnesium dopant concentration. A digital micromirror device is introduced to pattern incident UV radiation during InGaN growth, demonstrating that the...magnesium dopant concentration. A digital micromirror device is introduced to pattern incident UV radiation during InGaN growth, demonstrating that the...successful compositional patterning of InGaN using in situ digital micromirror device (DMD) patterning of ultraviolet (UV
Context-Aided Tracking with Adaptive Hyperspectral Imagery
2011-06-01
narrow spectral bands (e). . . . . . . . . . . . . . . . . . . . . 14 ix Figure Page 2.2. An illustration of a small portion of a digital micromirror ...incorporates two light paths: imaging and spectroscopy. Each pixel is steered towards a light path indepen- dently via the digital micromirror device (DMD...With the advent of digital micromirror device (DMD) arrays (DMA), the Rochester Institute of Technology Multi-Object Spectrometer (RITMOS) [36
The Process of Digitizing of Old Globe
NASA Astrophysics Data System (ADS)
Ambrožová, K.; Havrlanta, J.; Talich, M.; Böhm, O.
2016-06-01
This paper describes the process of digitalization of old globes that brings with it the possibility to use globes in their digital form. Created digital models are available to the general public through modern technology in the Internet network. This gives an opportunity to study old globes located in various historical collections, and prevent damage of the originals. Another benefit of digitization is also a possibility of comparing different models both among themselves and with current map data by increasing the transparency of individual layers. Digitization is carried out using special device that allows digitizing globes with a diameter ranging from 5 cm to 120 cm. This device can be easily disassembled, and it is fully mobile therefore the globes can be digitized in the place of its storage. Image data of globe surface are acquired by digital camera firmly fastened to the device. Acquired image data are then georeferenced by using a method of complex adjustment. The last step of digitization is publication of the final models that is realized by two ways. The first option is in the form of 3D model through JavaScript library Cesium or Google Earth plug-in in the Web browser. The second option is as a georeferenced map using Tile Map Service.
Applications of Digital Micromirror Devices to Astronomical Instrumentation
NASA Astrophysics Data System (ADS)
Robberto, M.
MEMS devices are among the major technological breakthroughs of the last two decades. Besides finding widespread use in high-tech and consumer market electronics, MEMS enable new types of astronomical instruments. I concentrate on Digital Micromirror Devices, which have been already adopted in astronomy and can enable scientific investigations that would otherwise remain beyond our technical capabilities.
Network device interface for digitally interfacing data channels to a controller via a network
NASA Technical Reports Server (NTRS)
Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor); Winkelmann, Joseph P. (Inventor); Konz, Daniel W. (Inventor)
2009-01-01
A communications system and method are provided for digitally connecting a plurality of data channels, such as sensors, actuators, and subsystems, to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. Data retrieved from the sensor is converted into digital signals and transmitted to the controller. Network device interfaces associated with different data channels can coordinate communications with the other interfaces based on either a transition in a command message sent by the bus controller or a synchronous clock signal.
Implementation of Adaptive Digital Controllers on Programmable Logic Devices
NASA Technical Reports Server (NTRS)
Gwaltney, David A.; King, Kenneth D.; Smith, Keary J.; Monenegro, Justino (Technical Monitor)
2002-01-01
Much has been made of the capabilities of FPGA's (Field Programmable Gate Arrays) in the hardware implementation of fast digital signal processing. Such capability also makes an FPGA a suitable platform for the digital implementation of closed loop controllers. Other researchers have implemented a variety of closed-loop digital controllers on FPGA's. Some of these controllers include the widely used proportional-integral-derivative (PID) controller, state space controllers, neural network and fuzzy logic based controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM-based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance requirements in a compact form-factor. Generally, a software implementation on a DSP (Digital Signal Processor) or microcontroller is used to implement digital controllers. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using digital signal processor (DSP) devices. While small form factor, commercial DSP devices are now available with event capture, data conversion, pulse width modulated (PWM) outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. In general, very few DSP devices are produced that are designed to meet any level of radiation tolerance or hardness. The goal of this effort is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive control algorithm approaches. An alternative is required for compact implementation of such functionality to withstand the harsh environment encountered on spacecraft. Radiation tolerant FPGA's are a feasible option for reaching this goal.
Network device interface for digitally interfacing data channels to a controller a via network
NASA Technical Reports Server (NTRS)
Konz, Daniel W. (Inventor); Ellerbrock, Philip J. (Inventor); Grant, Robert L. (Inventor); Winkelmann, Joseph P. (Inventor)
2006-01-01
The present invention provides a network device interface and method for digitally connecting a plurality of data channels to a controller using a network bus. The network device interface interprets commands and data received from the controller and polls the data channels in accordance with these commands. Specifically, the network device interface receives digital commands and data from the controller, and based on these commands and data, communicates with the data channels to either retrieve data in the case of a sensor or send data to activate an actuator. In one embodiment, the bus controller transmits messages to the network device interface containing a plurality of bits having a value defined by a transition between first and second states in the bits. The network device interface determines timing of the data sequence of the message and uses the determined timing to communicate with the bus controller.
NASA Astrophysics Data System (ADS)
Ochiai, T.; Nacher, J. C.
2011-09-01
Recently, the application of geometry and conformal mappings to artificial materials (metamaterials) has attracted the attention in various research communities. These materials, characterized by a unique man-made structure, have unusual optical properties, which materials found in nature do not exhibit. By applying the geometry and conformal mappings theory to metamaterial science, it may be possible to realize so-called "Harry Potter cloaking device". Although such a device is still in the science fiction realm, several works have shown that by using such metamaterials it may be possible to control the direction of the electromagnetic field at will. We could then make an object hidden inside of a cloaking device. Here, we will explain how to design invisibility device using differential geometry and conformal mappings.
Accuracy and eligibility of CBCT to digitize dental plaster casts.
Becker, Kathrin; Schmücker, Ulf; Schwarz, Frank; Drescher, Dieter
2018-05-01
Software-based dental planning requires digital casts and oftentimes cone-beam computed tomography (CBCT) radiography. However, buying a dedicated model digitizing device can be expensive and might not be required. The present study aimed to assess whether digital models derived from CBCT and models digitized using a dedicated optical device are of comparable accuracy. A total of 20 plaster casts were digitized with eight CBCT and five optical model digitizers. Corresponding models were superimposed using six control points and subsequent iterative closest point matching. Median distances were calculated among all registered models. Data were pooled per scanner and model. Boxplots were generated, and the paired t test, a Friedman test, and a post-hoc Nemenyi test were employed for statistical comparison. Results were found significant at p < 0.05. All CBCT devices allowed the digitization of plaster casts, but failed to reach the accuracy of the dedicated model digitizers (p < 0.001). Median distances between CBCT and optically digitized casts were 0.064 + - 0.005 mm. Qualitative differences among the CBCT systems were detected (χ 2 = 78.07, p < 0.001), and one CBCT providing a special plaster cast digitization mode was found superior to the competitors (p < 0.05). CBCT systems failed to reach the accuracy from optical digitizers, but within the limits of the study, accuracy appeared to be sufficient for digital planning and forensic purposes. Most CBCT systems enabled digitization of plaster casts, and accuracy was found sufficient for digital planning and storage purposes.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-31
... Certain Digital Photo Frames and Image Display Devices and Components Thereof, DN 2842; the Commission is... importation of certain digital photo frames and image display devices and components thereof. The complaint...
Spectrally Adaptable Compressive Sensing Imaging System
2014-05-01
signal recovering [?, ?]. The time-varying coded apertures can be implemented using micro-piezo motors [?] or through the use of Digital Micromirror ...feasibility of this testbed by developing a Digital- Micromirror -Device-based Snapshot Spectral Imaging (DMD-SSI) system, which implements CS measurement...Y. Wu, I. O. Mirza, G. R. Arce, and D. W. Prather, ”Development of a digital- micromirror - device- based multishot snapshot spectral imaging
ERIC Educational Resources Information Center
Kumar, Vikas; Sharma, Deepika
2016-01-01
Students in the digital era are habitual of using digital devices not only for playing and interacting with their friends and peers, but also as a tool for education and learning. These digital natives are highly obsessed with the internet driven portable devices and always demand for a multimedia rich content. This specific demand needs to be…
Spectral colors capture and reproduction based on digital camera
NASA Astrophysics Data System (ADS)
Chen, Defen; Huang, Qingmei; Li, Wei; Lu, Yang
2018-01-01
The purpose of this work is to develop a method for the accurate reproduction of the spectral colors captured by digital camera. The spectral colors being the purest color in any hue, are difficult to reproduce without distortion on digital devices. In this paper, we attempt to achieve accurate hue reproduction of the spectral colors by focusing on two steps of color correction: the capture of the spectral colors and the color characterization of digital camera. Hence it determines the relationship among the spectral color wavelength, the RGB color space of the digital camera device and the CIEXYZ color space. This study also provides a basis for further studies related to the color spectral reproduction on digital devices. In this paper, methods such as wavelength calibration of the spectral colors and digital camera characterization were utilized. The spectrum was obtained through the grating spectroscopy system. A photo of a clear and reliable primary spectrum was taken by adjusting the relative parameters of the digital camera, from which the RGB values of color spectrum was extracted in 1040 equally-divided locations. Calculated using grating equation and measured by the spectrophotometer, two wavelength values were obtained from each location. The polynomial fitting method for the camera characterization was used to achieve color correction. After wavelength calibration, the maximum error between the two sets of wavelengths is 4.38nm. According to the polynomial fitting method, the average color difference of test samples is 3.76. This has satisfied the application needs of the spectral colors in digital devices such as display and transmission.
ERIC Educational Resources Information Center
Cho, Vincent; Littenberg-Tobias, Joshua
2016-01-01
Even as digital devices (e.g., tablets, smart phones, laptops) have become increasingly ubiquitous in schools, concerns have also been raised that such devices might hinder students' social, emotional, and personal development. Educators' perspectives on such matters could shape the success or failure of 1:1 technology initiatives. Thus, there is…
2015-05-11
Micromirror Device (DMD) is a microelectromechanical (MEMS) device. A DMD consists of millions of electrostatically actuated micro- mirrors (or pixels...digital micromirror device) were analyzed. We discussed the effort of developing such a prototype by Proc. of SPIE Vol. 9484 94840I-11 Downloaded...to Digital Micromirror Device (DMD) Technology”, (n.d.) Retrieved May 1, 2011, from http://www.ti.com/lit/an/dlpa008a/dlpa008a.pdf. [16
Creating Digital Elevation Model Using a Mobile Device
NASA Astrophysics Data System (ADS)
Durmaz, A. İ.
2017-11-01
DEM (Digital Elevation Models) is the best way to interpret topography on the ground. In recent years, lidar technology allows to create more accurate elevation models. However, the problem is this technology is not common all over the world. Also if Lidar data are not provided by government agencies freely, people have to pay lots of money to reach these point clouds. In this article, we will discuss how we can create digital elevation model from less accurate mobile devices' GPS data. Moreover, we will evaluate these data on the same mobile device which we collected data to reduce cost of this modeling.
Offline Signature Verification Using the Discrete Radon Transform and a Hidden Markov Model
NASA Astrophysics Data System (ADS)
Coetzer, J.; Herbst, B. M.; du Preez, J. A.
2004-12-01
We developed a system that automatically authenticates offline handwritten signatures using the discrete Radon transform (DRT) and a hidden Markov model (HMM). Given the robustness of our algorithm and the fact that only global features are considered, satisfactory results are obtained. Using a database of 924 signatures from 22 writers, our system achieves an equal error rate (EER) of 18% when only high-quality forgeries (skilled forgeries) are considered and an EER of 4.5% in the case of only casual forgeries. These signatures were originally captured offline. Using another database of 4800 signatures from 51 writers, our system achieves an EER of 12.2% when only skilled forgeries are considered. These signatures were originally captured online and then digitally converted into static signature images. These results compare well with the results of other algorithms that consider only global features.
Detection of fragments from internal insects in wheat samples using a laboratory entoleter
USDA-ARS?s Scientific Manuscript database
A simple, rapid method was developed for estimating the number of insect fragments in flour caused by hidden, internal-feeding insects in whole grains during storage. The method uses a small mechanical rotary device (entoleter), which accelerates whole wheat kernels to high speeds and projects them...
Analysis of a digital RF memory in a signal-delay application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jelinek, D.A.
1992-03-01
Laboratory simulation of the approach of a radar fuze towards a target is an important factor in our ability to accurately measure the radar's performance. This simulation is achieved, in part, by dynamically delaying and attenuating the radar's transmitted pulse and sending the result back to the radar's receiver. Historically, the device used to perform the dynamic delay has been a limiting factor in the evaluation of a radar's performance and characteristics. A new device has been proposed that appears to have more capability than previous dynamic delay devices. This device is the digital RF memory. This report presents themore » results of an analysis of a digital RF memory used in a signal-delay application. 2 refs.« less
Uncovering the density of nanowire surface trap states hidden in the transient photoconductance.
Xu, Qiang; Dan, Yaping
2016-09-21
The gain of nanoscale photoconductors is closely correlated with surface trap states. Mapping out the density of surface trap states in the semiconductor bandgap is crucial for engineering the performance of nanoscale photoconductors. Traditional capacitive techniques for the measurement of surface trap states are not readily applicable to nanoscale devices. Here, we demonstrate a simple technique to extract the information on the density of surface trap states hidden in the transient photoconductance that is widely observed. With this method, we found that the density of surface trap states of a single silicon nanowire is ∼10(12) cm(-2) eV(-1) around the middle of the upper half bandgap.
Bezanilla, F
1985-03-01
A modified digital audio processor, a video cassette recorder, and some simple added circuitry are assembled into a recording device of high capacity. The unit converts two analog channels into digital form at 44-kHz sampling rate and stores the information in digital form in a common video cassette. Bandwidth of each channel is from direct current to approximately 20 kHz and the dynamic range is close to 90 dB. The total storage capacity in a 3-h video cassette is 2 Gbytes. The information can be retrieved in analog or digital form.
Bezanilla, F
1985-01-01
A modified digital audio processor, a video cassette recorder, and some simple added circuitry are assembled into a recording device of high capacity. The unit converts two analog channels into digital form at 44-kHz sampling rate and stores the information in digital form in a common video cassette. Bandwidth of each channel is from direct current to approximately 20 kHz and the dynamic range is close to 90 dB. The total storage capacity in a 3-h video cassette is 2 Gbytes. The information can be retrieved in analog or digital form. PMID:3978213
Re-thinking Reading in the Context of a New Wave of Electronic Reading Devices
NASA Astrophysics Data System (ADS)
Kratky, Andreas
We are currently witnessing a new wave of digital reading devices that will probably significantly change the way we read and publish. This is not the first digital revolution of aspects of cultural production and perception. This paper compares the previous digital revolutions of the music, film and publishing industries and attempts a prognosis of coming changes in the way we will work with digital texts. As a conclusion a new notion of interface design for the emerging reading ecology is proposed.
Manifold-Based Image Understanding
2010-06-30
3] employs a Texas Instruments digital micromirror device (DMD), which consists of an array of N electrostatically actuated micromirrors . The camera...image x) is reflected off a digital micromirror device (DMD) array whose mirror orientations are modulated in the pseudorandom pattern φm supplied by a
Development of an inherently digital transducer
NASA Technical Reports Server (NTRS)
Richard, R. R.
1972-01-01
The term digital transducer normally implies the combination of conventional analog sensors with encoders or analog-to-digital converters. Because of the objectionable characteristics of most digital transducers, a program was instituted to investigate the possibility of producing a transducer that is inherently digital, instead of a transducer that is digital in the usual sense. Such a device would have improved accuracy and reliability and would have reduced power and bulk requirements because two processes, sensing and conditioning, would be combined into one processes. A Curie-point-temperature sensor is described that represents realization of the stated goal. Also, a metal-insulator semiconductor is described that does not conform precisely to the program goals but that appears to have applications as a new and interesting transduction device.
Spatio-Temporal Pattern Mining on Trajectory Data Using Arm
NASA Astrophysics Data System (ADS)
Khoshahval, S.; Farnaghi, M.; Taleai, M.
2017-09-01
Preliminary mobile was considered to be a device to make human connections easier. But today the consumption of this device has been evolved to a platform for gaming, web surfing and GPS-enabled application capabilities. Embedding GPS in handheld devices, altered them to significant trajectory data gathering facilities. Raw GPS trajectory data is a series of points which contains hidden information. For revealing hidden information in traces, trajectory data analysis is needed. One of the most beneficial concealed information in trajectory data is user activity patterns. In each pattern, there are multiple stops and moves which identifies users visited places and tasks. This paper proposes an approach to discover user daily activity patterns from GPS trajectories using association rules. Finding user patterns needs extraction of user's visited places from stops and moves of GPS trajectories. In order to locate stops and moves, we have implemented a place recognition algorithm. After extraction of visited points an advanced association rule mining algorithm, called Apriori was used to extract user activity patterns. This study outlined that there are useful patterns in each trajectory that can be emerged from raw GPS data using association rule mining techniques in order to find out about multiple users' behaviour in a system and can be utilized in various location-based applications.
NASA Technical Reports Server (NTRS)
Athale, R. A.; Lee, S. H.
1978-01-01
The paper describes the fabrication and operation of an optical parallel logic (OPAL) device which performs Boolean algebraic operations on binary images. Several logic operations on two input binary images were demonstrated using an 8 x 8 device with a CdS photoconductor and a twisted nematic liquid crystal. Two such OPAL devices can be interconnected to form a half-adder circuit which is one of the essential components of a CPU in a digital signal processor.
17 CFR 23.202 - Daily trading records.
Code of Federal Regulations, 2014 CFR
2014-04-01
..., instant messaging, chat rooms, electronic mail, mobile device, or other digital or electronic media. Such...; (ii) Moneys borrowed and moneys loaned; (iii) The daily calculation of the value of each outstanding... rooms, electronic mail, mobile device, or other digital or electronic media; (2) Reliable timing data...
17 CFR 23.202 - Daily trading records.
Code of Federal Regulations, 2013 CFR
2013-04-01
..., instant messaging, chat rooms, electronic mail, mobile device, or other digital or electronic media. Such...; (ii) Moneys borrowed and moneys loaned; (iii) The daily calculation of the value of each outstanding... rooms, electronic mail, mobile device, or other digital or electronic media; (2) Reliable timing data...
37 CFR 251.71 - Commencement of proceedings.
Code of Federal Regulations, 2011 CFR
2011-07-01
.... 251.71 Section 251.71 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS... year in accordance with the requirements of this subchapter. (c) Digital audio recording devices and... manufacture and distribution in the United States, of any digital recording device or medium, any person...
37 CFR 251.71 - Commencement of proceedings.
Code of Federal Regulations, 2010 CFR
2010-07-01
.... 251.71 Section 251.71 Patents, Trademarks, and Copyrights COPYRIGHT OFFICE, LIBRARY OF CONGRESS... year in accordance with the requirements of this subchapter. (c) Digital audio recording devices and... manufacture and distribution in the United States, of any digital recording device or medium, any person...
The digital library: an oxymoron?
Guédon, J C
1999-01-01
"Virtual libraries" and "digital libraries" have become stock phrases of our times. But what do they really mean? While digital refers to a new form of document encoding and must be approached from that perspective, virtual resonates with aspects that modern philosophy treats with benign neglect at best. The word virtual harbors the notion of potential, and therein lies its hidden strength. Although strong commercial interests try to use the shift to a digital environment to redefine the political economy of knowledge, and thus virtualize libraries into a state of almost complete impotence, all hope is not lost. Librarians of virtualized libraries may well discover that they have re-empowered institutions if they place human interaction at the heart of their operations. In other words, rather than envisioning themselves as knowledge bankers sitting on treasure vaults of knowledge, they should see themselves as "hearts" dynamizing human communities. They should also see themselves as an essential part of these communities, and not as external repositories of knowledge. In this fashion, they will avoid the fate of becoming an oxymoron. PMID:9934524
A flexible microcontroller-based data acquisition device.
Hercog, Darko; Gergič, Bojan
2014-06-02
This paper presents a low-cost microcontroller-based data acquisition device. The key component of the presented solution is a configurable microcontroller-based device with an integrated USB transceiver and a 12-bit analogue-to-digital converter (ADC). The presented embedded DAQ device contains a preloaded program (firmware) that enables easy acquisition and generation of analogue and digital signals and data transfer between the device and the application running on a PC via USB bus. This device has been developed as a USB human interface device (HID). This USB class is natively supported by most of the operating systems and therefore any installation of additional USB drivers is unnecessary. The input/output peripheral of the presented device is not static but rather flexible, and could be easily configured to customised needs without changing the firmware. When using the developed configuration utility, a majority of chip pins can be configured as analogue input, digital input/output, PWM output or one of the SPI lines. In addition, LabVIEW drivers have been developed for this device. When using the developed drivers, data acquisition and signal processing algorithms as well as graphical user interface (GUI), can easily be developed using a well-known, industry proven, block oriented LabVIEW programming environment.
ERIC Educational Resources Information Center
Galuszka, Peter
2005-01-01
Using mobile digital devices--iPods, personal digital assistants (PDAs), Tablet PCs or advanced cell phones--is becoming a big campus trend. Their advantages include convenience and the ability to hear lectures or course-related music just about anywhere. PDA's such as Palm Pilots and BlackBerrys, iPods such as Apple's and Tablet PCs, including…
Quantitative optical scanning tests of complex microcircuits
NASA Technical Reports Server (NTRS)
Erickson, J. J.
1980-01-01
An approach for the development of the optical scanner as a screening inspection instrument for microcircuits involves comparing the quantitative differences in photoresponse images and then correlating them with electrical parameter differences in test devices. The existing optical scanner was modified so that the photoresponse data could be recorded and subsequently digitized. A method was devised for applying digital image processing techniques to the digitized photoresponse data in order to quantitatively compare the data. Electrical tests were performed and photoresponse images were recorded before and following life test intervals on two groups of test devices. Correlations were made between differences or changes in the electrical parameters of the test devices.
[A digital micromirror device-based Hadamard transform near infrared spectrometer].
Liu, Jia; Chen, Fen-Fei; Liao, Cheng-Sheng; Xu, Qian; Zeng, Li-Bo; Wu, Qiong-Shui
2011-10-01
A Hadamard transform near infrared spectrometer based on a digital micromirror device was constructed. The optical signal was collected by optical fiber, a grating was used for light diffraction, a digital micromirror device (DMD) was applied instead of traditional mechanical Hadamard masks for optical modulation, and an InGaAs near infrared detector was used as the optic sensor. The original spectrum was recovered by fast Hadamard transform algrithms. The advantages of the spectrometer, such as high resolution, signal-noise-ratio, stability, sensitivity and response speed were proved by experiments, which indicated that it is very suitable for oil and food-safety applications.
Experimental measurement-device-independent quantum digital signatures over a metropolitan network
NASA Astrophysics Data System (ADS)
Yin, Hua-Lei; Wang, Wei-Long; Tang, Yan-Lin; Zhao, Qi; Liu, Hui; Sun, Xiang-Xiang; Zhang, Wei-Jun; Li, Hao; Puthoor, Ittoop Vergheese; You, Li-Xing; Andersson, Erika; Wang, Zhen; Liu, Yang; Jiang, Xiao; Ma, Xiongfeng; Zhang, Qiang; Curty, Marcos; Chen, Teng-Yun; Pan, Jian-Wei
2017-04-01
Quantum digital signatures (QDSs) provide a means for signing electronic communications with information-theoretic security. However, all previous demonstrations of quantum digital signatures assume trusted measurement devices. This renders them vulnerable against detector side-channel attacks, just like quantum key distribution. Here we exploit a measurement-device-independent (MDI) quantum network, over a metropolitan area, to perform a field test of a three-party MDI QDS scheme that is secure against any detector side-channel attack. In so doing, we are able to successfully sign a binary message with a security level of about 10-7. Remarkably, our work demonstrates the feasibility of MDI QDSs for practical applications.
Analysis of a digital RF memory in a signal-delay application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jelinek, D.A.
1992-03-01
Laboratory simulation of the approach of a radar fuze towards a target is an important factor in our ability to accurately measure the radar`s performance. This simulation is achieved, in part, by dynamically delaying and attenuating the radar`s transmitted pulse and sending the result back to the radar`s receiver. Historically, the device used to perform the dynamic delay has been a limiting factor in the evaluation of a radar`s performance and characteristics. A new device has been proposed that appears to have more capability than previous dynamic delay devices. This device is the digital RF memory. This report presents themore » results of an analysis of a digital RF memory used in a signal-delay application. 2 refs.« less
Appendix C: Automated Vitrification of Mammalian Embryos on a Digital Microfluidic Device.
Liu, Jun; Pyne, Derek G; Abdelgawad, Mohamed; Sun, Yu
2017-01-01
This chapter introduces a digital microfluidic device that automates sample preparation for mammalian embryo vitrification. Individual microdroplets manipulated on the microfluidic device were used as microvessels to transport a single mouse embryo through a complete vitrification procedure. Advantages of this approach, compared to manual operation and channel-based microfluidic vitrification, include automated operation, cryoprotectant concentration gradient generation, and feasibility of loading and retrieval of embryos.
Kreutz, Jason E; Munson, Todd; Huynh, Toan; Shen, Feng; Du, Wenbin; Ismagilov, Rustem F
2011-11-01
This paper presents a protocol using theoretical methods and free software to design and analyze multivolume digital PCR (MV digital PCR) devices; the theory and software are also applicable to design and analysis of dilution series in digital PCR. MV digital PCR minimizes the total number of wells required for "digital" (single molecule) measurements while maintaining high dynamic range and high resolution. In some examples, multivolume designs with fewer than 200 total wells are predicted to provide dynamic range with 5-fold resolution similar to that of single-volume designs requiring 12,000 wells. Mathematical techniques were utilized and expanded to maximize the information obtained from each experiment and to quantify performance of devices and were experimentally validated using the SlipChip platform. MV digital PCR was demonstrated to perform reliably, and results from wells of different volumes agreed with one another. No artifacts due to different surface-to-volume ratios were observed, and single molecule amplification in volumes ranging from 1 to 125 nL was self-consistent. The device presented here was designed to meet the testing requirements for measuring clinically relevant levels of HIV viral load at the point-of-care (in plasma, <500 molecules/mL to >1,000,000 molecules/mL), and the predicted resolution and dynamic range was experimentally validated using a control sequence of DNA. This approach simplifies digital PCR experiments, saves space, and thus enables multiplexing using separate areas for each sample on one chip, and facilitates the development of new high-performance diagnostic tools for resource-limited applications. The theory and software presented here are general and are applicable to designing and analyzing other digital analytical platforms including digital immunoassays and digital bacterial analysis. It is not limited to SlipChip and could also be useful for the design of systems on platforms including valve-based and droplet-based platforms. In a separate publication by Shen et al. (J. Am. Chem. Soc., 2011, DOI: 10.1021/ja2060116), this approach is used to design and test digital RT-PCR devices for quantifying RNA.
Solaberrieta, Eneko; Garmendia, Asier; Minguez, Rikardo; Brizuela, Aritza; Pradies, Guillermo
2015-12-01
This article describes a virtual technique for transferring the location of a digitized cast from the patient to a virtual articulator (virtual facebow transfer). Using a virtual procedure, the maxillary digital cast is transferred to a virtual articulator by means of reverse engineering devices. The following devices necessary to carry out this protocol are available in many contemporary practices: an intraoral scanner, a digital camera, and specific software. Results prove the viability of integrating different tools and software and of completely integrating this procedure into a dental digital workflow. Copyright © 2015 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.
Geocaching: form, function, and opportunity
Ingrid E. Schneider; Deborah J. Chavez
2012-01-01
The role technology plays in outdoor recreation is evolving and of ongoing interest. One technology-related activity in particular emerged at the start of the 21st century: geocaching. Geocaching involves using a handheld GPS device to find hidden caches in areas based on clues posted on the Internet. Geocaching.com, the primary source for geocachers, provides...
Liberati, Nicola
2017-06-01
The aim of this paper is to analyse teledildonics from a phenomenological perspective in order to show the possible effects they will have on ourselves and on our society. The new way of using digital technologies is to merge digital activities with our everyday praxes, and there are already devices which enable subjects to be digitally connected in every moment of their lives. Even the most intimate ones are becoming mediated by devices such as teledildonics which digitally provide a tactual stimulation allowing users to have sexual intercourse through them. The efforts made in order to provide such an intertwinement of our everyday lives and digital technologies are evident, but the effects produced by them are not clear at all. This paper will analyse these technologies from a phenomenological perspective in order to understand their effects on the constitution of the subjects and on our society at the intimate level.
Digital Audio Sampling for Film and Video.
ERIC Educational Resources Information Center
Stanton, Michael J.
Digital audio sampling is explained, and some of its implications in digital sound applications are discussed. Digital sound equipment is rapidly replacing analog recording devices as the state-of-the-art in audio technology. The philosophy of digital recording involves doing away with the continuously variable analog waveforms and turning the…
Contexts of Digital Reading: How Genres Affect Reading Practices
ERIC Educational Resources Information Center
Morris, Janine
2016-01-01
"Contexts of Digital Reading: How Genres Affect Reading Practices" is a study of the different ways university students use digital devices to read. Many mainstream representations of digital reading fail to distinguish between different contexts or genres of reading, making digital reading appear transparent rather than mediated by…
Optimization of neural network architecture for classification of radar jamming FM signals
NASA Astrophysics Data System (ADS)
Soto, Alberto; Mendoza, Ariadna; Flores, Benjamin C.
2017-05-01
The purpose of this study is to investigate several artificial Neural Network (NN) architectures in order to design a cognitive radar system capable of optimally distinguishing linear Frequency-Modulated (FM) signals from bandlimited Additive White Gaussian Noise (AWGN). The goal is to create a theoretical framework to determine an optimal NN architecture to achieve a Probability of Detection (PD) of 95% or higher and a Probability of False Alarm (PFA) of 1.5% or lower at 5 dB Signal to Noise Ratio (SNR). Literature research reveals that the frequency-domain power spectral densities characterize a signal more efficiently than its time-domain counterparts. Therefore, the input data is preprocessed by calculating the magnitude square of the Discrete Fourier Transform of the digitally sampled bandlimited AWGN and linear FM signals to populate a matrix containing N number of samples and M number of spectra. This matrix is used as input for the NN, and the spectra are divided as follows: 70% for training, 15% for validation, and 15% for testing. The study begins by experimentally deducing the optimal number of hidden neurons (1-40 neurons), then the optimal number of hidden layers (1-5 layers), and lastly, the most efficient learning algorithm. The training algorithms examined are: Resilient Backpropagation, Scaled Conjugate Gradient, Conjugate Gradient with Powell/Beale Restarts, Polak-Ribiére Conjugate Gradient, and Variable Learning Rate Backpropagation. We determine that an architecture with ten hidden neurons (or higher), one hidden layer, and a Scaled Conjugate Gradient for training algorithm encapsulates an optimal architecture for our application.
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2012 CFR
2012-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2013 CFR
2013-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2014 CFR
2014-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
21 CFR 892.1715 - Full-field digital mammography system.
Code of Federal Regulations, 2011 CFR
2011-04-01
... planar digital x-ray images of the entire breast. This generic type of device may include digital mammography acquisition software, full-field digital image receptor, acquisition workstation, automatic exposure control, image processing and reconstruction programs, patient and equipment supports, component...
Mobile devices, Virtual Reality, Augmented Reality, and Digital Geoscience Education.
NASA Astrophysics Data System (ADS)
Crompton, H.; De Paor, D. G.; Whitmeyer, S. J.; Bentley, C.
2016-12-01
Mobile devices are playing an increasing role in geoscience education. Affordances include instructor-student communication and class management in large classrooms, virtual and augmented reality applications, digital mapping, and crowd-sourcing. Mobile technologies have spawned the sub field of mobile learning or m-learning, which is defined as learning across multiple contexts, through social and content interactions. Geoscientists have traditionally engaged in non-digital mobile learning via fieldwork, but digital devices are greatly extending the possibilities, especially for non-traditional students. Smartphones and tablets are the most common devices but smart glasses such as Pivothead enable live streaming of a first-person view (see for example, https://youtu.be/gWrDaYP5w58). Virtual reality headsets such as Google Cardboard create an immersive virtual field experience and digital imagery such as GigaPan and Structure from Motion enables instructors and/or students to create virtual specimens and outcrops that are sharable across the globe. Whereas virtual reality (VR) replaces the real world with a virtual representation, augmented reality (AR) overlays digital data on the live scene visible to the user in real time. We have previously reported on our use of the AR application called FreshAiR for geoscientific "egg hunts." The popularity of Pokémon Go demonstrates the potential of AR for mobile learning in the geosciences.
The Impact of Digital Mobile Devices in Higher Education
ERIC Educational Resources Information Center
Sevillano-García, M.ª Luisa; Vázquez-Cano, Esteban
2015-01-01
This research examined the acceptance, incidence, and use of digital mobile devices (tablets and smartphones) among university students in the European Higher Education Area (EHEA). The research was contextualized in a sample of 419 students from three Spanish public universities. Through a quantitative methodology, we identified the factors and…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-05-05
... Certain Electronic Devices Having a Digital Television Receiver and Components Thereof, DN 2801; the... importation of certain electronic devices having a digital television receiver and components thereof. The... health and welfare in the United States, competitive conditions in the United States economy, the...
NASA Technical Reports Server (NTRS)
1972-01-01
The assembly drawings of the receiver unit are presented for the data compression/error correction digital test system. Equipment specifications are given for the various receiver parts, including the TV input buffer register, delta demodulator, TV sync generator, memory devices, and data storage devices.
Multi-beam and single-chip LIDAR with discrete beam steering by digital micromirror device
NASA Astrophysics Data System (ADS)
Rodriguez, Joshua; Smith, Braden; Hellman, Brandon; Gin, Adley; Espinoza, Alonzo; Takashima, Yuzuru
2018-02-01
A novel Digital Micromirror Device (DMD) based beam steering enables a single chip Light Detection and Ranging (LIDAR) system for discrete scanning points. We present increasing number of scanning point by using multiple laser diodes for Multi-beam and Single-chip DMD-based LIDAR.
Lipid Bilayer-Integrated Optoelectronic Tweezers for Nanoparticle Manipulations
2013-01-01
intensities of ∼5 W/cm2 using a digital micromirror device (Texas Instruments, TX, USA). Figure 4a shows the overlapped image of the projected light...CMMI- 1120724). ■ ABBREVIATIONS ITO, indium tin oxide:; a-Si:H, hydrogenated amorphous silicon:; DMD, digital micromirror device; SLB, supported lipid
Digital Movement Analysis in Physical Education
ERIC Educational Resources Information Center
Trout, Josh
2013-01-01
Mobile devices such as smartphones and tablets offer applications (apps) that make digital movement analysis simple and efficient in physical education. Highly sophisticated movement analysis software has been available for many years but has mainly appealed to coaches of elite athletes and biomechanists. Apps on mobile devices are less expensive…
Reading Multimodally: What is Afforded?
ERIC Educational Resources Information Center
O'Brien, David; Voss, Scott
2011-01-01
Technological changes and the proliferation of digital devices have created new reading experiences for students. The rapid transition from print to digital texts is evident in the movement toward the adoption of an e-book standard, increasing sales of e-book readers and tablet devices, and projections that universities and public schools may use…
Bring Your Own Digital Device in Teacher Education
ERIC Educational Resources Information Center
Newhouse, C. Paul; Cooper, Martin; Pagram, Jeremy
2015-01-01
This article reports on an investigation to advise a teacher education institution on the feasibility of having a "Bring Your Own Digital Device" policy for students. The investigation built on components of two research projects while adding the comprehensive testing of representative potential hardware and software platforms. The…
Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices.
Pejović, Milić M; Denić, Dragan B; Pejović, Momčilo M; Nešić, Nikola T; Vasović, Nikola
2010-10-01
This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven by TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.
Microcontroller based system for electrical breakdown time delay measurement in gas-filled devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pejovic, Milic M.; Denic, Dragan B.; Pejovic, Momcilo M.
2010-10-15
This paper presents realization of a digital embedded system for measuring electrical breakdown time delay. The proposed system consists of three major parts: dc voltage supply, analog subsystem, and a digital subsystem. Any dc power source with the range from 100 to 1000 V can be used in this application. The analog subsystem should provide fast and accurate voltage switching on the testing device as well as transform the signals that represent the voltage pulse on the device and the device breakdown into the form suitable for detection by a digital subsystem. The insulated gate bipolar transistor IRG4PH40KD driven bymore » TC429 MOSFET driver is used for high voltage switching on the device. The aim of a digital subsystem is to detect the signals from the analog subsystem and to measure the elapsed time between their occurrences. Moreover, the digital subsystem controls various parameters that influence time delay and provides fast data storage for a large number of measured data. For this propose, we used the PIC18F4550 microcontroller with a full-speed compatible universal serial bus (USB) engine. Operation of this system is verified on different commercial and custom made gas devices with different structure and breakdown mechanisms. The electrical breakdown time delay measurements have been carried out as a function of several parameters, which dominantly influence electrical breakdown time delay. The obtained results have been verified using statistical methods, and they show good agreement with the theory. The proposed system shows good repeatability, sensitivity, and stability for measuring the electrical breakdown time delay.« less
Interactive display system having a digital micromirror imaging device
Veligdan, James T.; DeSanto, Leonard; Kaull, Lisa; Brewster, Calvin
2006-04-11
A display system includes a waveguide optical panel having an inlet face and an opposite outlet face. A projector cooperates with a digital imaging device, e.g. a digital micromirror imaging device, for projecting an image through the panel for display on the outlet face. The imaging device includes an array of mirrors tiltable between opposite display and divert positions. The display positions reflect an image light beam from the projector through the panel for display on the outlet face. The divert positions divert the image light beam away from the panel, and are additionally used for reflecting a probe light beam through the panel toward the outlet face. Covering a spot on the panel, e.g. with a finger, reflects the probe light beam back through the panel toward the inlet face for detection thereat and providing interactive capability.
Device Control Using Gestures Sensed from EMG
NASA Technical Reports Server (NTRS)
Wheeler, Kevin R.
2003-01-01
In this paper we present neuro-electric interfaces for virtual device control. The examples presented rely upon sampling Electromyogram data from a participants forearm. This data is then fed into pattern recognition software that has been trained to distinguish gestures from a given gesture set. The pattern recognition software consists of hidden Markov models which are used to recognize the gestures as they are being performed in real-time. Two experiments were conducted to examine the feasibility of this interface technology. The first replicated a virtual joystick interface, and the second replicated a keyboard.
A half-blind color image hiding and encryption method in fractional Fourier domains
NASA Astrophysics Data System (ADS)
Ge, Fan; Chen, Linfei; Zhao, Daomu
2008-09-01
We have proposed a new technique for digital image encryption and hiding based on fractional Fourier transforms with double random phases. An original hidden image is encrypted two times and the keys are increased to strengthen information protection. Color image hiding and encryption with wavelength multiplexing is proposed by embedding and encryption in R, G and B three channels. The robustness against occlusion attacks and noise attacks are analyzed. And computer simulations are presented with the corresponding results.
Electron beam directed energy device and methods of using same
Retsky, Michael W.
2007-10-16
A method and apparatus is disclosed for an electron beam directed energy device. The device consists of an electron gun with one or more electron beams. The device includes one or more accelerating plates with holes aligned for beam passage. The plates may be flat or preferably shaped to direct each electron beam to exit the electron gun at a predetermined orientation. In one preferred application, the device is located in outer space with individual beams that are directed to focus at a distant target to be used to impact and destroy missiles. The aimings of the separate beams are designed to overcome Coulomb repulsion. A method is also presented for directing the beams to a target considering the variable terrestrial magnetic field. In another preferred application, the electron beam is directed into the ground to produce a subsurface x-ray source to locate and/or destroy buried or otherwise hidden objects including explosive devices.
Laadan, Oren; Nieh, Jason; Phung, Dan
2012-10-02
Methods, media and systems for managing a distributed application running in a plurality of digital processing devices are provided. In some embodiments, a method includes running one or more processes associated with the distributed application in virtualized operating system environments on a plurality of digital processing devices, suspending the one or more processes, and saving network state information relating to network connections among the one or more processes. The method further include storing process information relating to the one or more processes, recreating the network connections using the saved network state information, and restarting the one or more processes using the stored process information.
Thermographic Nondestructive Evaluation of the Space Shuttle Main Engine Nozzle
NASA Technical Reports Server (NTRS)
Walker, James L.; Lansing, Matthew D.; Russell, Samuel S.; Caraccioli, Paul; Whitaker, Ann F. (Technical Monitor)
2000-01-01
The methods and results presented in this summary address the thermographic identification of interstitial leaks in the Space Shuttle Main Engine nozzles. A highly sensitive digital infrared camera is used to record the minute cooling effects associated with a leak source, such as a crack or pinhole, hidden within the nozzle wall by observing the inner "hot wall" surface as the nozzle is pressurized. These images are enhanced by digitally subtracting a thermal reference image taken before pressurization, greatly diminishing background noise. The method provides a nonintrusive way of localizing the tube that is leaking and the exact leak source position to within a very small axial distance. Many of the factors that influence the inspectability of the nozzle are addressed; including pressure rate, peak pressure, gas type, ambient temperature and surface preparation.
NASA Astrophysics Data System (ADS)
Bai, Hao; Zhang, Xi-wen
2017-06-01
While Chinese is learned as a second language, its characters are taught step by step from their strokes to components, radicals to components, and their complex relations. Chinese Characters in digital ink from non-native language writers are deformed seriously, thus the global recognition approaches are poorer. So a progressive approach from bottom to top is presented based on hierarchical models. Hierarchical information includes strokes and hierarchical components. Each Chinese character is modeled as a hierarchical tree. Strokes in one Chinese characters in digital ink are classified with Hidden Markov Models and concatenated to the stroke symbol sequence. And then the structure of components in one ink character is extracted. According to the extraction result and the stroke symbol sequence, candidate characters are traversed and scored. Finally, the recognition candidate results are listed by descending. The method of this paper is validated by testing 19815 copies of the handwriting Chinese characters written by foreign students.
Radiation Damage and Single Event Effect Results for Candidate Spacecraft Electronics
NASA Technical Reports Server (NTRS)
OBryan, Martha V.; LaBel, Kenneth A.; Reed, Robert A.; Howard, James W., Jr.; Ladbury, Ray L.; Barth, Janet L.; Kniffin, Scott D.; Seidleck, Christina M.; Marshall, Paul W.; Marshall, Cheryl J.;
2000-01-01
We present data on the vulnerability of a variety of candidate spacecraft electronics to proton and heavy-ion induced single-event effects and proton-induced damage. We also present data on the susceptibility of parts to functional degradation resulting from total ionizing dose at low dose rates (0.003-0.33 Rads(Si)/s). Devices tested include optoelectronics, digital, analog, linear bipolar, hybrid devices, Analog to Digital Converters (ADCs), Digital to Analog Converters (DACs), and DC-DC converters, among others.
Ultrawide Shipboard Electrooptic Electromagnetic Environment Monitoring
1994-05-01
ridge-waveguide modulator has a device length of 300 fpm, a waveguide thickness of 0.4 pm, a device capacitance of 0.2 pF, and a r x- 0.7. For digital ...important noise sources identified. Particular attention will be paid to the performance characteristics of the optical modulator. For digital ...1.32 tM for digital as well as analog optical link applications. The operation of the FKE modulator was discussed in Section 2.1.2 of this report. At
2005-09-01
of a system to store and retrieve digital/ wireless communication information from a pacemaker/ defibrillator, or other device , and to alert medical... wireless communication information from a pacemaker/defibrillator, or other device , and to alert medical personnel when a person is experiencing...with heart, pacing, program, test, sensor , circuit) where the individual needs immediate attention an audible alert will go off at the nurse’s
Device for modular input high-speed multi-channel digitizing of electrical data
VanDeusen, Alan L.; Crist, Charles E.
1995-09-26
A multi-channel high-speed digitizer module converts a plurality of analog signals to digital signals (digitizing) and stores the signals in a memory device. The analog input channels are digitized simultaneously at high speed with a relatively large number of on-board memory data points per channel. The module provides an automated calibration based upon a single voltage reference source. Low signal noise at such a high density and sample rate is accomplished by ensuring the A/D converters are clocked at the same point in the noise cycle each time so that synchronous noise sampling occurs. This sampling process, in conjunction with an automated calibration, yields signal noise levels well below the noise level present on the analog reference voltages.
A Flexible Microcontroller-Based Data Acquisition Device
Hercog, Darko; Gergič, Bojan
2014-01-01
This paper presents a low-cost microcontroller-based data acquisition device. The key component of the presented solution is a configurable microcontroller-based device with an integrated USB transceiver and a 12-bit analogue-to-digital converter (ADC). The presented embedded DAQ device contains a preloaded program (firmware) that enables easy acquisition and generation of analogue and digital signals and data transfer between the device and the application running on a PC via USB bus. This device has been developed as a USB human interface device (HID). This USB class is natively supported by most of the operating systems and therefore any installation of additional USB drivers is unnecessary. The input/output peripheral of the presented device is not static but rather flexible, and could be easily configured to customised needs without changing the firmware. When using the developed configuration utility, a majority of chip pins can be configured as analogue input, digital input/output, PWM output or one of the SPI lines. In addition, LabVIEW drivers have been developed for this device. When using the developed drivers, data acquisition and signal processing algorithms as well as graphical user interface (GUI), can easily be developed using a well-known, industry proven, block oriented LabVIEW programming environment. PMID:24892494
Control Board Digital Interface Input Devices – Touchscreen, Trackpad, or Mouse?
DOE Office of Scientific and Technical Information (OSTI.GOV)
Thomas A. Ulrich; Ronald L. Boring; Roger Lew
The authors collaborated with a power utility to evaluate input devices for use in the human system interface (HSI) for a new digital Turbine Control System (TCS) at a nuclear power plant (NPP) undergoing a TCS upgrade. A standalone dynamic software simulation of the new digital TCS and a mobile kiosk were developed to conduct an input device study to evaluate operator preference and input device effectiveness. The TCS software presented the anticipated HSI for the TCS and mimicked (i.e., simulated) the turbine systems’ responses to operator commands. Twenty-four licensed operators from the two nuclear power units participated in themore » study. Three input devices were tested: a trackpad, mouse, and touchscreen. The subjective feedback from the survey indicates the operators preferred the touchscreen interface. The operators subjectively rated the touchscreen as the fastest and most comfortable input device given the range of tasks they performed during the study, but also noted a lack of accuracy for selecting small targets. The empirical data suggest the mouse input device provides the most consistent performance for screen navigation and manipulating on screen controls. The trackpad input device was both empirically and subjectively found to be the least effective and least desired input device.« less
Reagor, David [Los Alamos, NM; Vasquez-Dominguez, Jose [Los Alamos, NM
2006-05-09
A method and apparatus for effective through-the-earth communication involves a signal input device connected to a transmitter operating at a predetermined frequency sufficiently low to effectively penetrate useful distances through-the earth, and having an analog to digital converter receiving the signal input and passing the signal input to a data compression circuit that is connected to an encoding processor, the encoding processor output being provided to a digital to analog converter. An amplifier receives the analog output from the digital to analog converter for amplifying said analog output and outputting said analog output to an antenna. A receiver having an antenna receives the analog output passes the analog signal to a band pass filter whose output is connected to an analog to digital converter that provides a digital signal to a decoding processor whose output is connected to an data decompressor, the data decompressor providing a decompressed digital signal to a digital to analog converter. An audio output device receives the analog output form the digital to analog converter for producing audible output.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-02-15
... Certain Display Devices, Including Digital Televisions and Monitors II, DN 2787; the Commission is... importation of certain display devices, including digital televisions and monitors II. The complaint names as... in the United States economy, the production of like or directly competitive articles in the United...
37 CFR 201.28 - Statements of Account for digital audio recording devices or media.
Code of Federal Regulations, 2010 CFR
2010-07-01
... following information for each unique combination of product category, technology, series or model number... quarterly period covered by the statement. (9) Technology of a device or medium is a digital audio recording... Congress. Forms and other information may be requested from the Licensing Division by facsimile...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-07-28
... appropriate advisory committee hot line/ phone line to learn about possible modifications before coming to the... premarket approval application for the Selenia C Digital Breast Tomosynthesis System, sponsored by Hologic, Inc. The Selenia C Digital Breast Tomosynthesis System is intended for use in the same clinical...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-11
... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-765] In the Matter of Certain Display Devices, Including Digital Televisions and Monitors II; Notice of Investigation AGENCY: U.S. International Trade... that a complaint was filed with the U.S. International Trade Commission on February 9, 2011, under...
Response to "Expanding Access to Learning with Mobile Digital Devices"
ERIC Educational Resources Information Center
Vanek, Jen
2017-01-01
In his article "Expanding Access to Learning with Mobile Digital Devices" (EJ1150752), Jeff Carter recommended a balanced perspective when measuring the potential of mobile learning to redefine teaching and learning for adults with basic skills needs. In response to Carter's article, the author makes some recommendations that she thinks…
Eight-Channel Digital Signal Processor and Universal Trigger Module
NASA Astrophysics Data System (ADS)
Skulski, Wojtek; Wolfs, Frank
2003-04-01
A 10-bit, 8-channel, 40 megasamples per second digital signal processor and waveform digitizer DDC-8 (nicknamed Universal Trigger Module) is presented. The digitizer features 8 analog inputs, 1 analog output for a reconstructed analog waveform, 16 NIM logic inputs, 8 NIM logic outputs, and a pool of 16 TTL logic lines which can be individually configured as either inputs or outputs. The first application of this device is to enhance the present trigger electronics for PHOBOS at RHIC. The status of the development and the first results are presented. Possible applications of the new device are discussed. Supported by the NSF grant PHY-0072204.
Algorithmic information theory and the hidden variable question
NASA Technical Reports Server (NTRS)
Fuchs, Christopher
1992-01-01
The admissibility of certain nonlocal hidden-variable theories are explained via information theory. Consider a pair of Stern-Gerlach devices with fixed nonparallel orientations that periodically perform spin measurements on identically prepared pairs of electrons in the singlet spin state. Suppose the outcomes are recorded as binary strings l and r (with l sub n and r sub n denoting their n-length prefixes). The hidden-variable theories considered here require that there exists a recursive function which may be used to transform l sub n into r sub n for any n. This note demonstrates that such a theory cannot reproduce all the statistical predictions of quantum mechanics. Specifically, consider an ensemble of outcome pairs (l,r). From the associated probability measure, the Shannon entropies H sub n and H bar sub n for strings l sub n and pairs (l sub n, r sub n) may be formed. It is shown that such a theory requires that the absolute value of H bar sub n - H sub n be bounded - contrasting the quantum mechanical prediction that it grow with n.
Deep-Subwavelength Resolving and Manipulating of Hidden Chirality in Achiral Nanostructures.
Zu, Shuai; Han, Tianyang; Jiang, Meiling; Lin, Feng; Zhu, Xing; Fang, Zheyu
2018-04-24
The chiral state of light plays a vital role in light-matter interactions and the consequent revolution of nanophotonic devices and advanced modern chiroptics. As the light-matter interaction goes into the nano- and quantum world, numerous chiroptical technologies and quantum devices require precise knowledge of chiral electromagnetic modes and chiral radiative local density of states (LDOS) distributions in detail, which directly determine the chiral light-matter interaction for applications such as chiral light detection and emission. With classical optical techniques failing to directly measure the chiral radiative LDOS, deep-subwavelength imaging and control of circular polarization (CP) light associated phenomena are introduced into the agenda. Here, we simultaneously reveal the hidden chiral electromagnetic mode and acquire its chiral radiative LDOS distribution of a single symmetric nanostructure at the deep-subwavelength scale by using CP-resolved cathodoluminescence (CL) microscopy. The chirality of the symmetric nanostructure under normally incident light excitation, resulting from the interference between the symmetric and antisymmetric modes of the V-shaped nanoantenna, is hidden in the near field with a giant chiral distribution (∼99%) at the arm-ends, which enables the circularly polarized CL emission from the radiative LDOS hot-spot and the following active helicity control at the deep-subwavelength scale. The proposed V-shaped nanostructure as a functional unit is further applied to the helicity-dependent binary encoding and the two-dimensional display applications. The proposed physical principle and experimental configuration can promote the future chiral characterization and manipulation at the deep-subwavelength scale and provide direct guidelines for the optimization of chiral light-matter interactions for future quantum studies.
ERIC Educational Resources Information Center
Taylor, Tony
2009-01-01
In August 2006, Australia's conservative prime minister John Howard convened a history summit in Canberra. The purported goal of the summit was the framing of a nationally-acceptable curriculum in Australian history. However, as this article suggests, Howard's hidden intention was to use the summit as a device for introducing a narrowly…
2010-10-01
mission, participants were given the NASA Task Load Index ( NASA TLX ) to measure subjective workload. Additional performance measures included mission...16 NASA TLX Workload Analyses...worksheet (See Appendix C), the Hidden Patterns Test (ETS, 1976), and an electronic form of the NASA Task Load Index ( TLX ; Hart & Staveland, 1988). The
The Hidden Costs of Owning a Microcomputer.
ERIC Educational Resources Information Center
McDole, Thomas L.
Before purchasing computer hardware, individuals must consider the costs associated with the setup and operation of a microcomputer system. Included among the initial costs of purchasing a computer are the costs of the computer, one or more disk drives, a monitor, and a printer as well as the costs of such optional peripheral devices as a plotter…
Picture Books in the Digital Age
ERIC Educational Resources Information Center
Serafini, Frank; Kachorsky, Danielle; Aguilera, Earl
2016-01-01
The design, publication, and features of contemporary narrative picturebooks have been impacted by the digital revolution and the emerging popularity of digital reading devices. Considering both the affordances and the limitations of digital picturebook apps can help readers, teachers, parents, and other educators make better decisions about the…
Bereznoy, A V; Saygitov, R T
Digital revolution is one of the major global trends resulting in the unprecedented scale and depth of penetration of information and communication technologies into all sectors of national economy, including healthcare. The development of this trend brought about high expectations related to the improvement of quality of medical assistance, accessibility and economic efficiency of healthcare services. However, euphoria of the first steps of digital revolution is passing now, opening doors to more realistic analysis of opportunities and conditions of realization of the true potential hidden in the digital transformation of healthcare. More balanced perception of the peculiarities of innovation processes in the sector is coming together with understanding of the serious barriers, hampering implementation of the new ideas and practices due to complicated interweaving of social, economic, ethical and psychological factors. When taking into account the industry specifics it becomes evident that digital revolution cannot be a quick turnaround but rather would pass a number of phases and is likely to last more than one decade. In this context the article focuses on the prospects of the new business models, capable of making significant changes in today’s economic landscape of the sector (including uber-medicine, retail clinics, retainer medicine, network models of medical services). The authors also provide assessment of the current situation and perspectives of digital healthcare development in Russia.
Implementation of Adaptive Digital Controllers on Programmable Logic Devices
NASA Technical Reports Server (NTRS)
Gwaltney, David A.; King, Kenneth D.; Smith, Keary J.; Ormsby, John (Technical Monitor)
2002-01-01
Much has been made of the capabilities of FPGA's (Field Programmable Gate Arrays) in the hardware implementation of fast digital signal processing (DSP) functions. Such capability also makes and FPGA a suitable platform for the digital implementation of closed loop controllers. There are myriad advantages to utilizing an FPGA for discrete-time control functions which include the capability for reconfiguration when SRAM- based FPGA's are employed, fast parallel implementation of multiple control loops and implementations that can meet space level radiation tolerance in a compact form-factor. Other researchers have presented the notion that a second order digital filter with proportional-integral-derivative (PID) control functionality can be implemented in an FPGA. At Marshall Space Flight Center, the Control Electronics Group has been studying adaptive discrete-time control of motor driven actuator systems using digital signal processor (DSF) devices. Our goal is to create a fully digital, flight ready controller design that utilizes an FPGA for implementation of signal conditioning for control feedback signals, generation of commands to the controlled system, and hardware insertion of adaptive control algorithm approaches. While small form factor, commercial DSP devices are now available with event capture, data conversion, pulse width modulated outputs and communication peripherals, these devices are not currently available in designs and packages which meet space level radiation requirements. Meeting our goals requires alternative compact implementation of such functionality to withstand the harsh environment encountered on spacecraft. Radiation tolerant FPGA's are a feasible option for reaching these goals.
Reconfigurable signal processor designs for advanced digital array radar systems
NASA Astrophysics Data System (ADS)
Suarez, Hernan; Zhang, Yan (Rockee); Yu, Xining
2017-05-01
The new challenges originated from Digital Array Radar (DAR) demands a new generation of reconfigurable backend processor in the system. The new FPGA devices can support much higher speed, more bandwidth and processing capabilities for the need of digital Line Replaceable Unit (LRU). This study focuses on using the latest Altera and Xilinx devices in an adaptive beamforming processor. The field reprogrammable RF devices from Analog Devices are used as analog front end transceivers. Different from other existing Software-Defined Radio transceivers on the market, this processor is designed for distributed adaptive beamforming in a networked environment. The following aspects of the novel radar processor will be presented: (1) A new system-on-chip architecture based on Altera's devices and adaptive processing module, especially for the adaptive beamforming and pulse compression, will be introduced, (2) Successful implementation of generation 2 serial RapidIO data links on FPGA, which supports VITA-49 radio packet format for large distributed DAR processing. (3) Demonstration of the feasibility and capabilities of the processor in a Micro-TCA based, SRIO switching backplane to support multichannel beamforming in real-time. (4) Application of this processor in ongoing radar system development projects, including OU's dual-polarized digital array radar, the planned new cylindrical array radars, and future airborne radars.
Systems and methods for performing wireless financial transactions
DOE Office of Scientific and Technical Information (OSTI.GOV)
McCown, Steven Harvey
2012-07-03
A secure computing module (SCM) is configured for connection with a host device. The SCM includes a processor for performing secure processing operations, a host interface for coupling the processor to the host device, and a memory connected to the processor wherein the processor logically isolates at least some of the memory from access by the host device. The SCM also includes a proximate-field wireless communicator connected to the processor to communicate with another SCM associated with another host device. The SCM generates a secure digital signature for a financial transaction package and communicates the package and the signature tomore » the other SCM using the proximate-field wireless communicator. Financial transactions are performed from person to person using the secure digital signature of each person's SCM and possibly message encryption. The digital signatures and transaction details are communicated to appropriate financial organizations to authenticate the transaction parties and complete the transaction.« less
Enterprise digital assistants: the progression of wireless clinical computing.
Bergeron, Bryan P
2002-01-01
By virtue of increasingly pervasive wireless connectivity, the proliferation of wireless handheld devices in clinical care is rapidly transforming the concept of the personal digital assistant (PDA) to the enterprise digital assistant (EDA). Wireless handheld devices are becoming extensions of the central hospital information system, in which it's understood that the health care enterprise, not the clinician carrying the information-dispensing device, owns the data. The practical implication for clinicians is that, despite the potential long-term benefits of seamless, just-in-time clinical data access, this paradigm shift portends decreased efficiency in the short term, as clinicians duplicate clinical data collection on private devices. Assuming eventual clinician acceptance, EDAs can form the basis of a national real-time clinical data acquisition system that ensures uniform prescribing, decision support, and diagnosis, and the means for tracking unusual disease presentation patterns that could be indicative of bioterrorism or natural disease outbreaks.
Digital devices: big challenge in color management
NASA Astrophysics Data System (ADS)
Vauderwange, Oliver; Curticapean, Dan; Dreβler, Paul; Wozniak, Peter
2014-09-01
The paper will present how the students learn to find technical solutions in color management by using adequate digital devices and recognize the specific upcoming tasks in this area. Several issues, problems and their solutions will be discussed. The scientific background offer specific didactical solutions in this area of optics. Color management is the major item of this paper. Color management is a crucial responsibility for media engineers and designers. Print, screen and mobile applications must independently display the same colors. Predictability and consistency in the color representation are the aims of a color management system. This is only possible in a standardized and audited production workflow. Nowadays digital media have a fast-paced development process. An increasing number of different digital devices with different display sizes and display technologies are a great challenge for every color management system. The authors will present their experience in the field of color management. The design and development of a suitable learning environment with the required infrastructure is in the focus. The combination of theoretical and practical lectures creates a deeper understanding in the area of the digital color representation.
Digital Forensics Using Local Signal Statistics
ERIC Educational Resources Information Center
Pan, Xunyu
2011-01-01
With the rapid growth of the Internet and the popularity of digital imaging devices, digital imagery has become our major information source. Meanwhile, the development of digital manipulation techniques employed by most image editing software brings new challenges to the credibility of photographic images as the definite records of events. We…
Design and fabrication of multimode interference couplers based on digital micro-mirror system
NASA Astrophysics Data System (ADS)
Wu, Sumei; He, Xingdao; Shen, Chenbo
2008-03-01
Multimode interference (MMI) couplers, based on the self-imaging effect (SIE), are accepted popularly in integrated optics. According to the importance of MMI devices, in this paper, we present a novel method to design and fabricate MMI couplers. A technology of maskless lithography to make MMI couplers based on a smart digital micro-mirror device (DMD) system is proposed. A 1×4 MMI device is designed as an example, which shows the present method is efficient and cost-effective.
A serial digital data communications device. [for real time flight simulation
NASA Technical Reports Server (NTRS)
Fetter, J. L.
1977-01-01
A general purpose computer peripheral device which is used to provide a full-duplex, serial, digital data transmission link between a Xerox Sigma computer and a wide variety of external equipment, including computers, terminals, and special purpose devices is reported. The interface has an extensive set of user defined options to assist the user in establishing the necessary data links. This report describes those options and other features of the serial communications interface and its performance by discussing its application to a particular problem.
Digital Devices in Classroom--Hesitations of Teachers-to-Be
ERIC Educational Resources Information Center
Lam, Paul; Tong, Aiden
2012-01-01
More and more teachers are facing the decision whether they should allow or promote students the use of technology in the classroom. The decision is difficult as there are apparently both advantages and disadvantages in doing either way. In terms of positive impacts, research revealed that the use of digital devices in the classroom setting was…
Digital Devices, Distraction, and Student Performance: Does In-Class Cell Phone Use Reduce Learning?
ERIC Educational Resources Information Center
Duncan, Douglas K.; Hoekstra, Angel R.; Wilcox, Bethany R.
2012-01-01
The recent increase in use of digital devices such as laptop computers, iPads, and web-enabled cell phones has generated concern about how technologies affect student performance. Combining observation, survey, and interview data, this research assesses the effects of technology use on student attitudes and learning. Data were gathered in eight…
Methods of Adapting Digital Content for the Learning Process via Mobile Devices
ERIC Educational Resources Information Center
Lopez, J. L. Gimenez; Royo, T. Magal; Laborda, Jesus Garcia; Calvo, F. Garde
2009-01-01
This article analyses different methods of adapting digital content for its delivery via mobile devices taking into account two aspects which are a fundamental part of the learning process; on the one hand, functionality of the contents, and on the other, the actual controlled navigation requirements that the learner needs in order to acquire high…
Formal Learning Sequences and Progression in the Studio: A Framework for Digital Design Education
ERIC Educational Resources Information Center
Wärnestål, Pontus
2016-01-01
This paper examines how to leverage the design studio learning environment throughout long-term Digital Design education in order to support students to progress from tactical, well-defined, device-centric routine design, to confidently design sustainable solutions for strategic, complex, problems for a wide range of devices and platforms in the…
ERIC Educational Resources Information Center
Zhu, Yi; Weng, T.; Cheng, Chung-Kuan
2009-01-01
Incorporating programmable logic devices (PLD) in digital design courses has become increasingly popular. The advantages of using PLDs, such as complex programmable logic devices (CPLDs) and field programmable gate arrays (FPGA), have been discussed before. However, previous studies have focused on the experiences from the point of view of the…
2015-01-01
streak tube imaging Lidar [15]. Nevertheless, instead of one- dimensional (1D) fan beam, a laser source modulates the digital micromirror device DMD and...Trans. Inform. Theory, vol. 52, pp. 1289-1306, 2006. [10] D. Dudley, W. Duncan and J. Slaughter, "Emerging Digital Micromirror Device (DMD) Applications
Parental Perception of Mobile Device Usage in Children and Social Competency
ERIC Educational Resources Information Center
Topper, Christin
2017-01-01
Parents in the 21st century are concerned with the ubiquity of mobile devices and their effects on the progression of social development. A review of the literature indicated that although digital interaction has become more prominent, limited empirical data existed on whether children who spend more time interacting in the digital realm would…
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-12
... Image Display Devices and Components Thereof; Notice of Request for Written Submissions on Remedy, the... importation, and the sale within the United States after importation of certain digital photo frames and image... the President, has 60 days to approve or disapprove the Commission's action. See section 337(j), 19 U...
ERIC Educational Resources Information Center
Dadey, Nathan; Lyons, Susan; DePascale, Charles
2018-01-01
Evidence of comparability is generally needed whenever there are variations in the conditions of an assessment administration, including variations introduced by the administration of an assessment on multiple digital devices (e.g., tablet, laptop, desktop). This article is meant to provide a comprehensive examination of issues relevant to the…
Device for modular input high-speed multi-channel digitizing of electrical data
VanDeusen, A.L.; Crist, C.E.
1995-09-26
A multi-channel high-speed digitizer module converts a plurality of analog signals to digital signals (digitizing) and stores the signals in a memory device. The analog input channels are digitized simultaneously at high speed with a relatively large number of on-board memory data points per channel. The module provides an automated calibration based upon a single voltage reference source. Low signal noise at such a high density and sample rate is accomplished by ensuring the A/D converters are clocked at the same point in the noise cycle each time so that synchronous noise sampling occurs. This sampling process, in conjunction with an automated calibration, yields signal noise levels well below the noise level present on the analog reference voltages. 1 fig.
Skimming Digits: Neuromorphic Classification of Spike-Encoded Images
Cohen, Gregory K.; Orchard, Garrick; Leng, Sio-Hoi; Tapson, Jonathan; Benosman, Ryad B.; van Schaik, André
2016-01-01
The growing demands placed upon the field of computer vision have renewed the focus on alternative visual scene representations and processing paradigms. Silicon retinea provide an alternative means of imaging the visual environment, and produce frame-free spatio-temporal data. This paper presents an investigation into event-based digit classification using N-MNIST, a neuromorphic dataset created with a silicon retina, and the Synaptic Kernel Inverse Method (SKIM), a learning method based on principles of dendritic computation. As this work represents the first large-scale and multi-class classification task performed using the SKIM network, it explores different training patterns and output determination methods necessary to extend the original SKIM method to support multi-class problems. Making use of SKIM networks applied to real-world datasets, implementing the largest hidden layer sizes and simultaneously training the largest number of output neurons, the classification system achieved a best-case accuracy of 92.87% for a network containing 10,000 hidden layer neurons. These results represent the highest accuracies achieved against the dataset to date and serve to validate the application of the SKIM method to event-based visual classification tasks. Additionally, the study found that using a square pulse as the supervisory training signal produced the highest accuracy for most output determination methods, but the results also demonstrate that an exponential pattern is better suited to hardware implementations as it makes use of the simplest output determination method based on the maximum value. PMID:27199646
Identity of Particles and Continuum Hypothesis
NASA Astrophysics Data System (ADS)
Berezin, Alexander A.
2001-04-01
Why all electrons are the same? Unlike other objects, particles and atoms (same isotopes) are forbidden to have individuality or personal history (or reveal their hidden variables, even if they do have them). Or at least, what we commonly call physics so far was unable to disprove particle's sameness (Berezin and Nakhmanson, Physics Essays, 1990). Consider two opposing hypotheses: (A) particles are indeed absolutely same, or (B) they do have individuality, but it is beyond our capacity to demonstrate. This dilemma sounds akin to undecidability of Continuum Hypothesis of existence (or not) of intermediate cardinalities between integers and reals (P.Cohen). Both yes and no of it are true. Thus, (alleged) sameness of electrons and atoms may be a physical translation (embodiment) of this fundamental Goedelian undecidability. Experiments unlikely to help: even if we find that all electrons are same within 30 decimal digits, could their masses (or charges) still differ in100-th digit? Within (B) personalized informationally rich (infinitely rich?) digital tails (starting at, say, 100-th decimal) may carry individual record of each particle history. Within (A) parameters (m, q) are indeed exactly same in all digits and their sameness is based on some inherent (meta)physical principle akin to Platonism or Eddington-type numerology.
Mier, José M; Molins, Laureano; Fibla, Juan J
2010-06-01
Persistent air leaks represent the most common pulmonary complication after elective lung resection. Since there are insufficient data in the literature regarding variability in the withdrawal of postoperative pleural drainages, we have designed a prospective, consecutive and comparative study to evaluate if the use of digital devices (Thopaz and DigiVent) to measure postoperative air leak compared to a Pleur-Evac varies on deciding when to withdraw chest tubes after lung resection. A prospective, consecutive and comparative trial was conducted in 75 patients who underwent elective pulmonary resection for non small cell lung cancer. This study compared two digitals devices with the current analogue version in 75 patients. The digital and analogue groups had 26, 24, and 25 patients, respectively. Clinical population data were not statistically different between the groups. The withdrawal of the chest tube was Thopaz, 2.4 days; Digivent, 3.3 days and PleurEvac, 4.5 days. Patients and nurses were subjectively more comfortable with digital devices. Surgeons obtained more objective information with digital devices. The safety mechanism of the Thopaz was also subjectively better, and one patient was discharged home without complications after one week. The digital and continuous measurement of air leak instead of the currently used static analogue systems reduced the chest tube withdrawal and hospital stay by more accurately and reproducibly measuring air leak. Intrapleural pressure curves from the Digivent may also help predict the optimal chest tube setting for each patient. The Thopaz alarm mechanism is very useful to prevent deficiencies in the mechanism and do not required wall suction. Copyright (c) 2010 AEC. Published by Elsevier Espana. All rights reserved.
Dynamic modal characterization of musical instruments using digital holography
NASA Astrophysics Data System (ADS)
Demoli, Nazif; Demoli, Ivan
2005-06-01
This study shows that a dynamic modal characterization of musical instruments with membrane can be carried out using a low-cost device and that the obtained very informative results can be presented as a movie. The proposed device is based on a digital holography technique using the quasi-Fourier configuration and time-average principle. Its practical realization with a commercial digital camera and large plane mirrors allows relatively simple analyzing of big vibration surfaces. The experimental measurements given for a percussion instrument are supported by the mathematical formulation of the problem.
Instrument for Real-Time Digital Nucleic Acid Amplification on Custom Microfluidic Devices
Selck, David A.
2016-01-01
Nucleic acid amplification tests that are coupled with a digital readout enable the absolute quantification of single molecules, even at ultralow concentrations. Digital methods are robust, versatile and compatible with many amplification chemistries including isothermal amplification, making them particularly invaluable to assays that require sensitive detection, such as the quantification of viral load in occult infections or detection of sparse amounts of DNA from forensic samples. A number of microfluidic platforms are being developed for carrying out digital amplification. However, the mechanistic investigation and optimization of digital assays has been limited by the lack of real-time kinetic information about which factors affect the digital efficiency and analytical sensitivity of a reaction. Commercially available instruments that are capable of tracking digital reactions in real-time are restricted to only a small number of device types and sample-preparation strategies. Thus, most researchers who wish to develop, study, or optimize digital assays rely on the rate of the amplification reaction when performed in a bulk experiment, which is now recognized as an unreliable predictor of digital efficiency. To expand our ability to study how digital reactions proceed in real-time and enable us to optimize both the digital efficiency and analytical sensitivity of digital assays, we built a custom large-format digital real-time amplification instrument that can accommodate a wide variety of devices, amplification chemistries and sample-handling conditions. Herein, we validate this instrument, we provide detailed schematics that will enable others to build their own custom instruments, and we include a complete custom software suite to collect and analyze the data retrieved from the instrument. We believe assay optimizations enabled by this instrument will improve the current limits of nucleic acid detection and quantification, improving our fundamental understanding of single-molecule reactions and providing advancements in practical applications such as medical diagnostics, forensics and environmental sampling. PMID:27760148
A three-dimensional evaluation of a laser scanner and a touch-probe scanner.
Persson, Anna; Andersson, Matts; Oden, Agneta; Sandborgh-Englund, Gunilla
2006-03-01
The fit of a dental restoration depends on quality throughout the entire manufacturing process. There is difficulty in assessing the surface topography of an object with a complex form, such as teeth, since there is no exact reference form. The purpose of this study was to determine the repeatability and relative accuracy of 2 dental surface digitization devices. A computer-aided design (CAD) technique was used for evaluation to calculate and present the deviations 3-dimensionally. Ten dies of teeth prepared for complete crowns were fabricated in presintered yttria-stabilized tetragonal zirconia (Y-TZP). The surfaces were digitized 3 times each with an optical or mechanical digitizer. The number of points in the point clouds from each reading were calculated and used as the CAD reference model (CRM). Alignments were performed by registration software that works by minimizing a distance criterion. In color-difference maps, the distribution of the discrepancies between the surfaces in the CRM and the 3-dimensional surface models was identified and located. The repeatability of both scanners was within 10 microm, based on SD and absolute mean values. The qualitative evaluation resulted in an even distribution of the deviations in the optical digitizer, whereas the dominating part of the surfaces in the mechanical digitizer showed no deviations. The relative accuracy of the 2 surface digitization devices was within +/- 6 microm, based on median values. The repeatability of the optical digitizer was comparable with the mechanical digitization device, and the relative accuracy was similar.
Image compression system and method having optimized quantization tables
NASA Technical Reports Server (NTRS)
Ratnakar, Viresh (Inventor); Livny, Miron (Inventor)
1998-01-01
A digital image compression preprocessor for use in a discrete cosine transform-based digital image compression device is provided. The preprocessor includes a gathering mechanism for determining discrete cosine transform statistics from input digital image data. A computing mechanism is operatively coupled to the gathering mechanism to calculate a image distortion array and a rate of image compression array based upon the discrete cosine transform statistics for each possible quantization value. A dynamic programming mechanism is operatively coupled to the computing mechanism to optimize the rate of image compression array against the image distortion array such that a rate-distortion-optimal quantization table is derived. In addition, a discrete cosine transform-based digital image compression device and a discrete cosine transform-based digital image compression and decompression system are provided. Also, a method for generating a rate-distortion-optimal quantization table, using discrete cosine transform-based digital image compression, and operating a discrete cosine transform-based digital image compression and decompression system are provided.
NASA Astrophysics Data System (ADS)
Chang, S. S. L.
State of the art technology in circuits, fields, and electronics is discussed. The principles and applications of these technologies to industry, digital processing, microwave semiconductors, and computer-aided design are explained. Important concepts and methodologies in mathematics and physics are reviewed, and basic engineering sciences and associated design methods are dealt with, including: circuit theory and the design of magnetic circuits and active filter synthesis; digital signal processing, including FIR and IIR digital filter design; transmission lines, electromagnetic wave propagation and surface acoustic wave devices. Also considered are: electronics technologies, including power electronics, microwave semiconductors, GaAs devices, and magnetic bubble memories; digital circuits and logic design.
Development of digital stethoscope for telemedicine.
Lakhe, Aparna; Sodhi, Isha; Warrier, Jyothi; Sinha, Vineet
2016-01-01
The stethoscope is a medical acoustic device which is used to auscultate internal body sounds, mainly the heart and lungs. A digital stethoscope overcomes the limitations of a conventional stethoscope as the sound data is transformed into electrical signals which can be amplified, stored, replayed and, more importantly, sent for an expert opinion, making it very useful in telemedicine. With the above in view, a low cost digital stethoscope has been developed which is interfaceble with mobile communication devices. In this instrument sounds from various locations can be captured with the help of an electret condenser microphone. Captured sound is filtered, amplified and processed digitally using an adaptive line enhancement technique to obtain audible and distinct heart sounds.
NASA Astrophysics Data System (ADS)
Jara Casas, L. M.; Ceresa, D.; Kulis, S.; Miryala, S.; Christiansen, J.; Francisco, R.; Gnani, D.
2017-02-01
A Digital RADiation (DRAD) test chip has been specifically designed to study the impact of Total Ionizing Dose (TID) (<1 Grad) and Single Event Upset (SEU) on digital logic gates in a 65 nm CMOS technology. Nine different versions of standard cell libraries are studied in this chip, basically differing in the device dimensions, Vt flavor and layout of the device. Each library has eighteen test structures specifically designed to characterize delay degradation and power consumption of the standard cells. For SEU study, a dedicated test structure based on a shift register is designed for each library. TID results up to 500 Mrad are reported.
Silicon Schottky Diode Safe Operating Area
NASA Technical Reports Server (NTRS)
Casey, Megan C.; Campola, Michael J.; Lauenstein, Jean-Marie; Wilcox, Edward P.; Phan, Anthony M.; LaBel, Kenneth A.
2016-01-01
Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.
3D-printed microfluidic automation.
Au, Anthony K; Bhattacharjee, Nirveek; Horowitz, Lisa F; Chang, Tim C; Folch, Albert
2015-04-21
Microfluidic automation - the automated routing, dispensing, mixing, and/or separation of fluids through microchannels - generally remains a slowly-spreading technology because device fabrication requires sophisticated facilities and the technology's use demands expert operators. Integrating microfluidic automation in devices has involved specialized multi-layering and bonding approaches. Stereolithography is an assembly-free, 3D-printing technique that is emerging as an efficient alternative for rapid prototyping of biomedical devices. Here we describe fluidic valves and pumps that can be stereolithographically printed in optically-clear, biocompatible plastic and integrated within microfluidic devices at low cost. User-friendly fluid automation devices can be printed and used by non-engineers as replacement for costly robotic pipettors or tedious manual pipetting. Engineers can manipulate the designs as digital modules into new devices of expanded functionality. Printing these devices only requires the digital file and electronic access to a printer.
Large-scale femtoliter droplet array for digital counting of single biomolecules.
Kim, Soo Hyeon; Iwai, Shino; Araki, Suguru; Sakakihara, Shouichi; Iino, Ryota; Noji, Hiroyuki
2012-12-07
We present a novel device employing one million femtoliter droplets immobilized on a substrate for the quantitative detection of extremely low concentrations of biomolecules in a sample. Surface-modified polystyrene beads carrying either zero or a single biomolecule-reporter enzyme complex are efficiently isolated into femtoliter droplets formed on hydrophilic-in-hydrophobic surfaces. Using a conventional micropipette, this is achieved by sequential injection first with an aqueous solution containing beads, and then with fluorinated oil. The concentration of target biomolecules is estimated from the ratio of the number of signal-emitting droplets to the total number of trapped beads (digital counting). The performance of our digital counting device was demonstrated by detecting a streptavidin-β-galactosidase conjugate with a limit of detection (LOD) of 10 zM. The sensitivity of our device was >20-fold higher than that noted in previous studies where a smaller number of reactors (fifty thousand reactors) were used. Such a low LOD was achieved because of the large number of droplets in an array, allowing simultaneous examination of a large number of beads. When combined with bead-based enzyme-linked immunosorbent assay (digital ELISA), the LOD for the detection of prostate specific antigen reached 2 aM. This value, again, was improved over that noted in a previous study, because of the decreased coefficient of variance of the background measurement determined by the Poisson noise. Our digital counting device using one million droplets has great potential as a highly sensitive, portable immunoassay device that could be used to diagnose diseases.
Steganalysis of recorded speech
NASA Astrophysics Data System (ADS)
Johnson, Micah K.; Lyu, Siwei; Farid, Hany
2005-03-01
Digital audio provides a suitable cover for high-throughput steganography. At 16 bits per sample and sampled at a rate of 44,100 Hz, digital audio has the bit-rate to support large messages. In addition, audio is often transient and unpredictable, facilitating the hiding of messages. Using an approach similar to our universal image steganalysis, we show that hidden messages alter the underlying statistics of audio signals. Our statistical model begins by building a linear basis that captures certain statistical properties of audio signals. A low-dimensional statistical feature vector is extracted from this basis representation and used by a non-linear support vector machine for classification. We show the efficacy of this approach on LSB embedding and Hide4PGP. While no explicit assumptions about the content of the audio are made, our technique has been developed and tested on high-quality recorded speech.
Digital Literacy: A Prerequisite for Effective Learning in a Blended Learning Environment?
ERIC Educational Resources Information Center
Tang, Chun Meng; Chaw, Lee Yen
2016-01-01
Blended learning has propelled into mainstream education in recent years with the help of digital technology. Commonly available digital devices and the Internet have made access to learning resources such as learning management systems, online libraries, digital media, etc. convenient and flexible for both lecturers and students. Beyond the…
Adolescents' Out-of-School Digital Reading Practices
ERIC Educational Resources Information Center
Zucker, Lauren
2018-01-01
Adolescents spend a significant portion of the day on digital devices, yet we know very little about their out-of-school reading practices. While screen recording technology allows researchers to record and view videos of digital reading, the majority of studies exploring digital reading limit participants' reading to researcher-selected texts and…
Picturebooks 2.0: Transmedial Features across Narrative Platforms
ERIC Educational Resources Information Center
Serafini, Frank; Kachorsky, Dani; Aguilera, Earl
2015-01-01
Like other multimodal texts, the design, publication, and delivery of contemporary picture-books have been impacted by the digital revolution and the affordances of digital reading devices. Print-based picture-books are being published alongside digital narratives, and new digital picture-books are being created that no long begin as print-based…
Digital Course Materials: A Case Study of the Apple iPad in the Academic Environment
ERIC Educational Resources Information Center
Cameron, Andrea H.; Bush, Michael H.
2011-01-01
The newness of the iPad device creates a phenomenon unique and unstudied in the academic environment. By merging the innovations of electronic text, e-reader, and multi-modal functionality, the iPad tablet device can act as an e-reader providing digital course materials as well as a range of other supplementary academic applications. This…
Tools of Engagement: Status Report on Technology in Early Childhood Education
ERIC Educational Resources Information Center
Simon, Fran; Donohue, Chip
2011-01-01
In recent years, a tidal wave of mobile digital devices and applications (apps) has found its way into the daily lives of early childhood professionals everywhere. It is safe to say that the speed at which new digital devices and apps get into people's hands will not slow down. This article presents a status report on technology in early childhood…
Digital Readers: The Next Chapter in E-Book Reading and Response
ERIC Educational Resources Information Center
Larson, Lotta C.
2010-01-01
The basic features of digital reading devices (such as the Amazon Kindle) are described in this article. The author also considers how such devices can advance e-book readership among primary students by offering new avenues for accessing and interacting with a wide array of texts. Rooted in the transactional theory of reader response and a new…
Digital Distraction: Shedding Light on the 21st-Century College Classroom
ERIC Educational Resources Information Center
Aaron, Lynn S.; Lipton, Talia
2018-01-01
It is not uncommon to walk into a college classroom and find all heads bowed down to a flashing screen and the room . . . silent. While digital devices can certainly support learning, what about when they are a distraction? This study explored this 21st-century phenomenon from two perspectives: Does the use of a device for nonacademic purposes…
Microstereolithography: A Review
2003-04-01
initiator Table I. Characteristics of the integral microstereolithography machines described by Bertsch, Chatwin and Loubere. b) Digital Micromirror ...DeviceTM as pattern generator The Digital Micromirror Device (DMDTM) produced by Texas Instruments, which is an array of micromirrors actuated by...feasibility of the technology, an array of micromirrors having a VGA resolution (640 x 480) was used in a first prototype developed to work with visible
Podcasting and Digital Video in the Classroom: A Call for Research
ERIC Educational Resources Information Center
Newman, John H.
2011-01-01
A case is directed at digital immigrants to utilize mobile computing devices such as an Apple iPod to deliver content to students in self-contained special education classrooms. The author discusses the current state of the use of iPods in classrooms, and how research using these devices has been limited to institutions of higher learning, while…
Image display device in digital TV
Choi, Seung Jong [Seoul, KR
2006-07-18
Disclosed is an image display device in a digital TV that is capable of carrying out the conversion into various kinds of resolution by using single bit map data in the digital TV. The image display device includes: a data processing part for executing bit map conversion, compression, restoration and format-conversion for text data; a memory for storing the bit map data obtained according to the bit map conversion and compression in the data processing part and image data inputted from an arbitrary receiving part, the receiving part receiving one of digital image data and analog image data; an image outputting part for reading the image data from the memory; and a display processing part for mixing the image data read from the image outputting part and the bit map data converted in format from the a data processing part. Therefore, the image display device according to the present invention can convert text data in such a manner as to correspond with various resolution, carry out the compression for bit map data, thereby reducing the memory space, and support text data of an HTML format, thereby providing the image with the text data of various shapes.
Signal processing: opportunities for superconductive circuits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ralston, R.W.
1985-03-01
Prime motivators in the evolution of increasingly sophisticated communication and detection systems are the needs for handling ever wider signal bandwidths and higher data processing speeds. These same needs drive the development of electronic device technology. Until recently the superconductive community has been tightly focused on digital devices for high speed computers. The purpose of this paper is to describe opportunities and challenges which exist for both analog and digital devices in a less familiar area, that of wideband signal processing. The function and purpose of analog signal-processing components, including matched filters, correlators and Fourier transformers, will be described andmore » examples of superconductive implementations given. A canonic signal-processing system is then configured using these components in combination with analog/digital converters and digital output circuits to highlight the important issues of dynamic range, accuracy and equivalent computation rate. Superconductive circuits hold promise for processing signals of 10-GHz bandwidth. Signal processing systems, however, can be properly designed and implemented only through a synergistic combination of the talents of device physicists, circuit designers, algorithm architects and system engineers. An immediate challenge to the applied superconductivity community is to begin sharing ideas with these other researchers.« less
Non-local boxes and their implementation in Minecraft
NASA Astrophysics Data System (ADS)
Simnacher, Timo Yannick
PR-boxes are binary devices connecting two remote parties satisfying x AND y = a + b mod 2, where x and y denote the binary inputs and a and b are the respective outcomes without signaling. These devices are named after their inventors Sandu Popescu and Daniel Rohrlich and saturate the Clauser-Horne-Shimony-Holt (CHSH) inequality. This Bell-like inequality bounds the correlation that can exist between two remote, non-signaling, classical systems described by local hidden variable theories. Experiments have now convincingly shown that quantum entanglement cannot be explained by local hidden variable theories. Furthermore, the CHSH inequality provides a method to distinguish quantum systems from super-quantum correlations. The correlation between the outputs of the PR-box goes beyond any quantum entanglement. Though PR-boxes would have impressive consequences, as far as we know they are not physically realizable. However, by introducing PR-boxes to Minecraft as part of the redstone system, which simulates the electrical components for binary computing, we can experience the consequences of super-quantum correlations. For instance, Wim van Dam proved that two parties can use a sufficient number of PR-boxes to compute any Boolean function f(x,y) with only one bit of communication.
McEwan, Thomas E.
1998-01-01
A radar range finder and hidden object locator is based on ultra-wide band radar with a high resolution swept range gate. The device generates an equivalent time amplitude scan with atypical range of 4 inches to 20 feet, and an analog range resolution as limited by a jitter of on the order of 0.01 inches. A differential sampling receiver is employed to effectively eliminate ringing and other aberrations induced in the receiver by the near proximity of the transmit antenna, so a background subtraction is not needed, simplifying the circuitry while improving performance. Uses of the invention include a replacement of ultrasound devices for fluid level sensing, automotive radar, such as cruise control and parking assistance, hidden object location, such as stud and rebar finding. Also, this technology can be used when positioned over a highway lane to collect vehicle count and speed data for traffic control. Techniques are used to reduce clutter in the receive signal, such as decoupling the receive and transmit cavities by placing a space between them, using conductive or radiative damping elements on the cavities, and using terminating plates on the sides of the openings.
McEwan, T.E.
1998-06-30
A radar range finder and hidden object locator is based on ultra-wide band radar with a high resolution swept range gate. The device generates an equivalent time amplitude scan with atypical range of 4 inches to 20 feet, and an analog range resolution as limited by a jitter of on the order of 0.01 inches. A differential sampling receiver is employed to effectively eliminate ringing and other aberrations induced in the receiver by the near proximity of the transmit antenna, so a background subtraction is not needed, simplifying the circuitry while improving performance. Uses of the invention include a replacement of ultrasound devices for fluid level sensing, automotive radar, such as cruise control and parking assistance, hidden object location, such as stud and rebar finding. Also, this technology can be used when positioned over a highway lane to collect vehicle count and speed data for traffic control. Techniques are used to reduce clutter in the receive signal, such as decoupling the receive and transmit cavities by placing a space between them, using conductive or radiative damping elements on the cavities, and using terminating plates on the sides of the openings. 20 figs.
S-Band POSIX Device Drivers for RTEMS
NASA Technical Reports Server (NTRS)
Lux, James P.; Lang, Minh; Peters, Kenneth J.; Taylor, Gregory H.
2011-01-01
This is a set of POSIX device driver level abstractions in the RTEMS RTOS (Real-Time Executive for Multiprocessor Systems real-time operating system) to SBand radio hardware devices that have been instantiated in an FPGA (field-programmable gate array). These include A/D (analog-to-digital) sample capture, D/A (digital-to-analog) sample playback, PLL (phase-locked-loop) tuning, and PWM (pulse-width-modulation)-controlled gain. This software interfaces to Sband radio hardware in an attached Xilinx Virtex-2 FPGA. It uses plug-and-play device discovery to map memory to device IDs. Instead of interacting with hardware devices directly, using direct-memory mapped access at the application level, this driver provides an application programming interface (API) offering that easily uses standard POSIX function calls. This simplifies application programming, enables portability, and offers an additional level of protection to the hardware. There are three separate device drivers included in this package: sband_device (ADC capture and DAC playback), pll_device (RF front end PLL tuning), and pwm_device (RF front end AGC control).
Pearce, Julia M; Rubin, G James; Selke, Piet; Amlôt, Richard; Mowbray, Fiona; Rogers, M Brooke
2013-04-01
Incidents involving the exposure of large numbers of people to radiological material can have serious consequences for those affected, their community and wider society. In many instances, the psychological effects of these incidents have the greatest impact. People fear radiation and even incidents which result in little or no actual exposure have the potential to cause widespread anxiety and behavior change. The aim of this study was to assess public intentions, beliefs and information needs in the UK and Germany in response to a hidden radiological exposure device. By assessing how the public is likely to react to such events, strategies for more effective crisis and risk communication can be developed and designed to address any knowledge gaps, misperceptions and behavioral responses that are contrary to public health advice. This study had three stages. The first stage consisted of focus groups which identified perceptions of and reactions to a covert radiological device. The incident was introduced to participants using a series of mock newspaper and broadcast injects to convey the evolving scenario. The outcomes of these focus groups were used to inform national telephone surveys, which quantified intended behaviors and assessed what perceptions were correlated with these behaviors. Focus group and survey results were used to develop video and leaflet communication interventions, which were then evaluated in a second round of focus groups. In the first two stages, misperceptions about the likelihood and routes of exposure were associated with higher levels of worry and greater likelihood of engaging in behaviors that might be detrimental to ongoing public health efforts. The final focus groups demonstrated that both types of misunderstanding are amenable to change following targeted communication. Should terrorists succeed in placing a hidden radiological device in a public location, then health agencies may find that it is easier to communicate effectively with the public if they explicitly and clearly discuss the mechanisms through which someone could be affected by the radiation and the known geographical spread of any risk. Messages which explain how the risk from a hidden radiological device "works" should be prepared and tested in advance so that they can be rapidly deployed if the need arises.
Digital Device Architecture and the Safe Use of Flash Devices in Munitions
NASA Technical Reports Server (NTRS)
Katz, Richard B.; Flowers, David; Bergevin, Keith
2017-01-01
Flash technology is being utilized in fuzed munition applications and, based on the development of digital logic devices in the commercial world, usage of flash technology will increase. Digital devices of interest to designers include flash-based microcontrollers and field programmable gate arrays (FPGAs). Almost a decade ago, a study was undertaken to determine if flash-based microcontrollers could be safely used in fuzes and, if so, how should such devices be applied. The results were documented in the Technical Manual for the Use of Logic Devices in Safety Features. This paper will first review the Technical Manual and discuss the rationale behind the suggested architectures for microcontrollers and a brief review of the concern about data retention in flash cells. An architectural feature in the microcontroller under study will be discussed and its use will show how to screen for weak or failed cells during manufacture, storage, or immediately prior to use. As was done for microcontrollers a decade ago, architectures for a flash-based FPGA will be discussed, showing how it can be safely used in fuzes. Additionally, architectures for using non-volatile (including flash-based) storage will be discussed for SRAM-based FPGAs.
Mathieson, Kathleen; Leafman, Joan S; Horton, Mark B
2017-01-01
Health care access for medically underserved patients managing chronic conditions is challenging. While telemedicine can support patient education and engagement, the "digital divide" may be particularly problematic among the medically underserved. This study evaluated physical access to digital devices, use of e-mail and social media tools, and perceptions of telemedicine among American Indian (AI) patients with diabetes mellitus (DM). Survey data were collected from AI patients with DM during teleophthalmology exams. Eighty-eight percent of patients had access to digital device(s), 70% used e-mail, and 56% used social media. Younger age and greater education were positively associated with e-mail and social media use (p < .05). Most (60%) considered telemedicine an excellent medium for health-related patient education. American Indian patients with DM had access enabling patient education via telemedicine. Future work should examine patient technology preferences and effectiveness of technology-based education in improving outcomes among medically underserved populations.
Optical system design of dynamic infrared scene projector based on DMD
NASA Astrophysics Data System (ADS)
Lu, Jing; Fu, Yuegang; Liu, Zhiying; Li, Yandong
2014-09-01
Infrared scene simulator is now widely used to simulate infrared scene practicality in the laboratory, which can greatly reduce the research cost of the optical electrical system and offer economical experiment environment. With the advantage of large dynamic range and high spatial resolution, dynamic infrared projection technology, which is the key part of the infrared scene simulator, based on digital micro-mirror device (DMD) has been rapidly developed and widely applied in recent years. In this paper, the principle of the digital micro-mirror device is briefly introduced and the characteristics of the DLP (Digital Light Procession) system based on digital micromirror device (DMD) are analyzed. The projection system worked at 8~12μm with 1024×768 pixel DMD is designed by ZEMAX. The MTF curve is close to the diffraction limited curve and the radius of the spot diagram is smaller than that of the airy disk. The result indicates that the system meets the design requirements.
Optical scanning holography based on compressive sensing using a digital micro-mirror device
NASA Astrophysics Data System (ADS)
A-qian, Sun; Ding-fu, Zhou; Sheng, Yuan; You-jun, Hu; Peng, Zhang; Jian-ming, Yue; xin, Zhou
2017-02-01
Optical scanning holography (OSH) is a distinct digital holography technique, which uses a single two-dimensional (2D) scanning process to record the hologram of a three-dimensional (3D) object. Usually, these 2D scanning processes are in the form of mechanical scanning, and the quality of recorded hologram may be affected due to the limitation of mechanical scanning accuracy and unavoidable vibration of stepper motor's start-stop. In this paper, we propose a new framework, which replaces the 2D mechanical scanning mirrors with a Digital Micro-mirror Device (DMD) to modulate the scanning light field, and we call it OSH based on Compressive Sensing (CS) using a digital micro-mirror device (CS-OSH). CS-OSH can reconstruct the hologram of an object through the use of compressive sensing theory, and then restore the image of object itself. Numerical simulation results confirm this new type OSH can get a reconstructed image with favorable visual quality even under the condition of a low sample rate.
Teacher perceptions of usefulness of mobile learning devices in rural secondary science classrooms
NASA Astrophysics Data System (ADS)
Tighe, Lisa
The internet and easy accessibility to a wide range of digital content has created the necessity for teachers to embrace and integrate digitial media in their curriculums. Although there is a call for digital media integration in curriculum by current learning standards, rural schools continue to have access to fewer resources due to limited budgets, potentially preventing teachers from having access to the most current technology and science instructional materials. This dissertation identifies the perceptions rural secondary science teachers have on the usefulness of mobile learning devices in the science classroom. The successes and challenges in using mobile learning devices in the secondary classroom were also explored. Throughout this research, teachers generally supported the integration of mobile devices in the classroom, while harboring some concerns relating to student distractability and the time required for integrating mobile devices in exisiting curriculum. Quantitative and qualitative data collected through surveys, interviews, and classroom observations revealed that teachers perceive that mobile devices bring benefits such as ease of communication and easy access to digitial information. However, there are perceived challenges with the ability to effectively communicate complex scientific information via mobile devices, distractibility of students, and the time required to develop effective curriculum to integrate digital media into the secondary science classroom.
Advanced 3-V semiconductor technology assessment
NASA Technical Reports Server (NTRS)
Nowogrodzki, M.
1983-01-01
Components required for extensions of currently planned space communications systems are discussed for large antennas, crosslink systems, single sideband systems, Aerostat systems, and digital signal processing. Systems using advanced modulation concepts and new concepts in communications satellites are included. The current status and trends in materials technology are examined with emphasis on bulk growth of semi-insulating GaAs and InP, epitaxial growth, and ion implantation. Microwave solid state discrete active devices, multigigabit rate GaAs digital integrated circuits, microwave integrated circuits, and the exploratory development of GaInAs devices, heterojunction devices, and quasi-ballistic devices is considered. Competing technologies such as RF power generation, filter structures, and microwave circuit fabrication are discussed. The fundamental limits of semiconductor devices and problems in implementation are explored.
Detecting underwater improvised explosive threats (DUIET)
NASA Astrophysics Data System (ADS)
Feeley, Terry
2010-04-01
Improvised Explosive Devices (IEDs) have presented a major threat in the wars in Afghanistan and Iraq. These devices are powerful homemade land mines that can be small and easily hidden near roadsides. They are then remotely detonated when Coalition Forces pass by either singly or in convoys. Their rapid detection, classification and destruction is key to the safety of troops in the area. These land based bombs will have an analogue in the underwater theater especially in ports, lakes, rivers and streams. These devices may be used against Americans on American soil as an element of the global war on terrorism (GWOT) Rapid detection and classification of underwater improvised explosive devices (UIED) is critical to protecting innocent lives and maintaining the day to day flow of commerce. This paper will discuss a strategy and tool set to deal with this potential threat.
NASA Astrophysics Data System (ADS)
Singh, Arun K.; Auton, Gregory; Hill, Ernie; Song, Aimin
2018-07-01
Due to a very high carrier concentration and low band gap, graphene based self-switching diodes do not demonstrate a very high rectification ratio. Despite that, it takes the advantage of graphene’s high carrier mobility and has been shown to work at very high microwave frequencies. However, the AC component of these devices is hidden in the very linear current–voltage characteristics. Here, we extract and quantitatively study the device capacitance that determines the device nonlinearity by implementing a conformal mapping technique. The estimated value of the nonlinear component or curvature coefficient from DC results based on Shichman–Hodges model predicts the rectified output voltage, which is in good agreement with the experimental RF results.
Connected word recognition using a cascaded neuro-computational model
NASA Astrophysics Data System (ADS)
Hoya, Tetsuya; van Leeuwen, Cees
2016-10-01
We propose a novel framework for processing a continuous speech stream that contains a varying number of words, as well as non-speech periods. Speech samples are segmented into word-tokens and non-speech periods. An augmented version of an earlier-proposed, cascaded neuro-computational model is used for recognising individual words within the stream. Simulation studies using both a multi-speaker-dependent and speaker-independent digit string database show that the proposed method yields a recognition performance comparable to that obtained by a benchmark approach using hidden Markov models with embedded training.
The Challenges of Digital Leadership
ERIC Educational Resources Information Center
McLeod, Scott
2015-01-01
Because digital devices and online environments can simultaneously be transformatively empowering and maddeningly disruptive, the work of integrating digital learning tools into schools is usually difficult and complex. Common challenges arise, however, and can be thoughtfully addressed by proactive leadership. In the end, technology change in…
NASA Technical Reports Server (NTRS)
Leviton, Douglas B. (Inventor)
1993-01-01
A device for position encoding of a rotating shaft in which a polygonal mirror having a number of facets is mounted to the shaft and a light beam is directed towards the facets is presented. The facets of the polygonal mirror reflect the light beam such that a light spot is created on a linear array detector. An analog-to-digital converter is connected to the linear array detector for reading the position of the spot on the linear array detector. A microprocessor with memory is connected to the analog-to-digital converter to hold and manipulate the data provided by the analog-to-digital converter on the position of the spot and to compute the position of the shaft based upon the data from the analog-to-digital converter.
3D-Printed Microfluidic Automation
Au, Anthony K.; Bhattacharjee, Nirveek; Horowitz, Lisa F.; Chang, Tim C.; Folch, Albert
2015-01-01
Microfluidic automation – the automated routing, dispensing, mixing, and/or separation of fluids through microchannels – generally remains a slowly-spreading technology because device fabrication requires sophisticated facilities and the technology’s use demands expert operators. Integrating microfluidic automation in devices has involved specialized multi-layering and bonding approaches. Stereolithography is an assembly-free, 3D-printing technique that is emerging as an efficient alternative for rapid prototyping of biomedical devices. Here we describe fluidic valves and pumps that can be stereolithographically printed in optically-clear, biocompatible plastic and integrated within microfluidic devices at low cost. User-friendly fluid automation devices can be printed and used by non-engineers as replacement for costly robotic pipettors or tedious manual pipetting. Engineers can manipulate the designs as digital modules into new devices of expanded functionality. Printing these devices only requires the digital file and electronic access to a printer. PMID:25738695
ERIC Educational Resources Information Center
Wohlwend, Karen E.
2015-01-01
This article examines the digital literacy practices that emerge when young children play together with digital apps on touchscreen devices. Children's collaborative composing with a digital puppetry app on a touchscreen--with many hands all busy dragging, resizing, and animating puppet characters, and many voices making sound effects, narrating,…
Teaching Young Readers to Navigate a Digital Story When Rules Keep Changing
ERIC Educational Resources Information Center
Javorsky, Kristin; Trainin, Guy
2014-01-01
As mobile technologies such as tablets and smartphones offer opportunities to view stories in digital format, young readers are faced with new challenges in the reading task. The authors conducted an exploratory study of digital story applications on a mobile reading device and found that digital story applications are capable of taking large…
ERIC Educational Resources Information Center
Fleer, Marilyn
2016-01-01
In the early childhood education literature, a growing number of studies have referenced "digital play." Many of these studies seek to describe how young children play with digital devices, notably, how they engage with different kinds of apps. This work collectively illustrates a range of play behaviours where a number of important…
ERIC Educational Resources Information Center
Gonzalez, Michael
2014-01-01
The introduction of the Internet and its hyperlinked content made easily accessible with portable digital devices like smart phones and tablets, posed challenges to the traditional linear and print-oriented notions of what it means to read and write. Now that these traditional notions of read and write literacy have been breached by these…
The utility of six over-the-counter (home) pregnancy tests.
Cole, Laurence A
2011-08-01
The home pregnancy market is rapidly evolving. It has moved from detection of pregnancy on the day of missed menstrual bleeding, to detection claims 4 days prior. It is moving from all manual tests to digital tests, with a monitor reading the bands and informing women they are pregnant. A thorough study is needed to investigate the validity of claims and evolving usefulness of devices. Studies were proposed to examine the sensitivity and specificity of home tests and their abilities to detect pregnancy. Methods examined the abilities of tests to detect human chorionic gonadotropin (hCG), hyperglycosylated hCG, free β-subunit, a mixture of these antigens in 40 individual early pregnancy urines. Using a mixture of hCG, hyperglycosylated hCG and free β-subunit typical for early pregnancy, the sensitivity of the First Response manual and digital tests was 5.5 mIU/mL, while the sensitivities of the EPT and ClearBlue brand manual and digital tests was 22 mIU/mL. On further evaluation, the First Response manual and digital tests both detected 97% of 120 pregnancies on the day of missed menstrual bleeding. The EPT manual and digital devices detected 54% and 67% of pregnancies, respectively, and the ClearBlue manual and digital devices detected 64% and 54% of pregnancies, respectively. First Response manual and digital claim >99% detection on the day of missed menses. The results here suggest similar sensitivity for these two tests. The EPT and ClearBlue manual and digital test make similar >99% claims, the data presented here disputes their elevated claim.
"Palmar pivot flap" for resurfacing palmar lateral defects of the fingers.
Yam, Andrew; Peng, Yeong-Pin; Pho, Robert Wan-Heng
2008-12-01
Soft tissue defects on the lateral borders of the digits are difficult to reconstruct using local or local-regional flaps. We describe a "palmar pivot flap" to resurface an adjacent defect on the palmar-lateral aspect of the digit. The surgical technique is described. This flap is an axial pattern flap based on the subcutaneous transverse branches of the digital artery. The flap is pivoted up to 90 degrees on the neurovascular bundle in its base, into an adjacent defect. The flap can be raised from either the proximal or the middle phalangeal segments. It can cover defects sited from the level of the proximal interphalangeal joint up to the fingertip. The donor defect is limited to the same digit and is covered with a full-thickness skin graft. We have used this flap on 3 patients with defects at the middle phalangeal segment, the distal interphalangeal joint, and the fingertip. All healed primarily. One patient had a mild flexion contracture of the proximal interphalangeal joint, whereas the other 2 had no complications. The patients with distal interphalangeal joint and fingertip defects had excellent sensation in the flap (2-point discrimination of 5-6 mm). The palmar pivot flap is useful for resurfacing otherwise difficult defects on the lateral borders of the digits around and distal to the proximal interphalangeal joint, including those at the fingertip. It provides sensate, glabrous skin. The donor defect is on the same digit and is well hidden, producing an aesthetic and functional reconstruction.
NASA Astrophysics Data System (ADS)
Yamada, Takayuki; Gohshi, Seiichi; Echizen, Isao
A method is described to prevent video images and videos displayed on screens from being re-shot by digital cameras and camcorders. Conventional methods using digital watermarking for re-shooting prevention embed content IDs into images and videos, and they help to identify the place and time where the actual content was shot. However, these methods do not actually prevent digital content from being re-shot by camcorders. We developed countermeasures to stop re-shooting by exploiting the differences between the sensory characteristics of humans and devices. The countermeasures require no additional functions to use-side devices. It uses infrared light (IR) to corrupt the content recorded by CCD or CMOS devices. In this way, re-shot content will be unusable. To validate the method, we developed a prototype system and implemented it on a 100-inch cinema screen. Experimental evaluations showed that the method effectively prevents re-shooting.
A nanocryotron comparator can connect single-flux-quantum circuits to conventional electronics
NASA Astrophysics Data System (ADS)
Zhao, Qing-Yuan; McCaughan, Adam N.; Dane, Andrew E.; Berggren, Karl K.; Ortlepp, Thomas
2017-04-01
Integration with conventional electronics offers a straightforward and economical approach to upgrading existing superconducting technologies, such as scaling up superconducting detectors into large arrays and combining single flux quantum (SFQ) digital circuits with semiconductor logic gates and memories. However, direct output signals from superconducting devices (e.g., Josephson junctions) are usually not compatible with the input requirements of conventional devices (e.g., transistors). Here, we demonstrate the use of a single three-terminal superconducting-nanowire device, called the nanocryotron (nTron), as a digital comparator to combine SFQ circuits with mature semiconductor circuits such as complementary metal oxide semiconductor (CMOS) circuits. Since SFQ circuits can digitize output signals from general superconducting devices and CMOS circuits can interface existing CMOS-compatible electronics, our results demonstrate the feasibility of a general architecture that uses an nTron as an interface to realize a ‘super-hybrid’ system consisting of superconducting detectors, superconducting quantum electronics, CMOS logic gates and memories, and other conventional electronics.
Holmström, Oscar; Linder, Nina; Lundin, Mikael; Moilanen, Hannu; Suutala, Antti; Turkki, Riku; Joensuu, Heikki; Isola, Jorma; Diwan, Vinod; Lundin, Johan
2015-01-01
Introduction A significant barrier to medical diagnostics in low-resource environments is the lack of medical care and equipment. Here we present a low-cost, cloud-connected digital microscope for applications at the point-of-care. We evaluate the performance of the device in the digital assessment of estrogen receptor-alpha (ER) expression in breast cancer samples. Studies suggest computer-assisted analysis of tumor samples digitized with whole slide-scanners may be comparable to manual scoring, here we study whether similar results can be obtained with the device presented. Materials and Methods A total of 170 samples of human breast carcinoma, immunostained for ER expression, were digitized with a high-end slide-scanner and the point-of-care microscope. Corresponding regions from the samples were extracted, and ER status was determined visually and digitally. Samples were classified as ER negative (<1% ER positivity) or positive, and further into weakly (1–10% positivity) and strongly positive. Interobserver agreement (Cohen’s kappa) was measured and correlation coefficients (Pearson’s product-momentum) were calculated for comparison of the methods. Results Correlation and interobserver agreement (r = 0.98, p < 0.001, kappa = 0.84, CI95% = 0.75–0.94) were strong in the results from both devices. Concordance of the point-of-care microscope and the manual scoring was good (r = 0.94, p < 0.001, kappa = 0.71, CI95% = 0.61–0.80), and comparable to the concordance between the slide scanner and manual scoring (r = 0.93, p < 0.001, kappa = 0.69, CI95% = 0.60–0.78). Fourteen (8%) discrepant cases between manual and device-based scoring were present with the slide scanner, and 16 (9%) with the point-of-care microscope, all representing samples of low ER expression. Conclusions Tumor ER status can be accurately quantified with a low-cost imaging device and digital image-analysis, with results comparable to conventional computer-assisted or manual scoring. This technology could potentially be expanded for other histopathological applications at the point-of-care. PMID:26659386
Handheld computers and the 21st century surgical team: a pilot study.
Aziz, Omer; Panesar, Sukhmeet S; Netuveli, Gopalakrishnan; Paraskeva, Paraskevas; Sheikh, Aziz; Darzi, Ara
2005-08-18
The commercial development and expansion of mobile phone networks has led to the creation of devices combining mobile phones and personal digital assistants, which could prove invaluable in a clinical setting. This pilot study aimed to look at how one such device compared with the current pager system in facilitating inter-professional communication in a hospital clinical team. The study looked at a heterogeneous team of doctors (n = 9) working in a busy surgical setting at St. Mary's Hospital in London and compared the use of a personal digital assistant with mobile phone and web-browsing facilities to the existing pager system. The primary feature of this device being compared to the conventional pager was its use as a mobile phone, but other features evaluated included the ability to access the internet, and reference data on the device. A crossover study was carried out for 6 weeks in 2004, with the team having access to the personal digital assistant every alternate week. The primary outcome measure for assessing efficiency of communication was the length of time it took for clinicians to respond to a call. We also sought to assess the ease of adoption of new technology by evaluating the perceptions of the team (n = 9) to personal digital assistants, by administering a questionnaire. Doctors equipped with a personal digital assistant rather than a pager, responded more quickly to a call and had a lower of failure to respond rate (RR: 0.44; 95%CI 0.20-0.93). Clinicians also found this technology easy to adopt as seen by a significant reduction in perceptions of nervousness to the technology over the six-week study period (mean (SD) week 1: 4.10 (SD 1.69) vs. mean (SD) week 6: 2.20 (1.99); p = 0.04). The results of this pilot study show the possible effects of replacing the current hospital pager with a newer, more technologically advanced device, and suggest that a combined personal digital assistant and mobile phone device may improve communication between doctors. In the light of these encouraging preliminary findings, we propose a large-scale clinical trial of the use of these devices in facilitating inter-professional communication in a hospital setting.
NASA Astrophysics Data System (ADS)
Carlotti, D.; Collamati, F.; Faccini, R.; Fresch, P.; Iacoangeli, F.; Mancini-Terracciano, C.; Marafini, M.; Mirabelli, R.; Recchia, L.; Russomando, A.; Solfaroli Camillocci, E.; Toppi, M.; Traini, G.; Bocci, V.
2017-11-01
The recent interest in β^- radionuclides for radio-guided surgery derives from the feature of the β radiation to release energy in few millimeters of tissue. Such feature can be used to locate residual tumors with a probe located in its immediate vicinity, determining the resection margins with an accuracy of millimeters. The drawback of this technique is that it does not allow to identify tumors hidden in more than few mm of tissue. Conversely, the bremsstrahlung X-rays emitted by the interaction of the β- radiation with the nuclei of the tissue are relatively penetrating. To complement the β- probes, we have therefore developed a detector based on cadmium telluride, an X-ray detector with a high quantum efficiency working at room temperature. We measured the secondary emission of bremsstrahlung photons in a target of Polymethylmethacrylate (PMMA) with a density similar to living tissue. The results show that this device allows to detect a 1 ml residual or lymph-node with an activity of 1 kBq hidden under a layer of 10 mm of PMMA with a 3:1 signal to noise, i.e. with a five sigma discrimination in less than 5 s.
Droplet Digital Enzyme-Linked Oligonucleotide Hybridization Assay for Absolute RNA Quantification.
Guan, Weihua; Chen, Liben; Rane, Tushar D; Wang, Tza-Huei
2015-09-03
We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples.
Droplet Digital Enzyme-Linked Oligonucleotide Hybridization Assay for Absolute RNA Quantification
Guan, Weihua; Chen, Liben; Rane, Tushar D.; Wang, Tza-Huei
2015-01-01
We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples. PMID:26333806
Droplet Digital Enzyme-Linked Oligonucleotide Hybridization Assay for Absolute RNA Quantification
NASA Astrophysics Data System (ADS)
Guan, Weihua; Chen, Liben; Rane, Tushar D.; Wang, Tza-Huei
2015-09-01
We present a continuous-flow droplet-based digital Enzyme-Linked Oligonucleotide Hybridization Assay (droplet digital ELOHA) for sensitive detection and absolute quantification of RNA molecules. Droplet digital ELOHA incorporates direct hybridization and single enzyme reaction via the formation of single probe-RNA-probe (enzyme) complex on magnetic beads. It enables RNA detection without reverse transcription and PCR amplification processes. The magnetic beads are subsequently encapsulated into a large number of picoliter-sized droplets with enzyme substrates in a continuous-flow device. This device is capable of generating droplets at high-throughput. It also integrates in-line enzymatic incubation and detection of fluorescent products. Our droplet digital ELOHA is able to accurately quantify (differentiate 40% difference) as few as ~600 RNA molecules in a 1 mL sample (equivalent to 1 aM or lower) without molecular replication. The absolute quantification ability of droplet digital ELOHA is demonstrated with the analysis of clinical Neisseria gonorrhoeae 16S rRNA to show its potential value in real complex samples.
Energy efficient cooperation in underlay RFID cognitive networks for a water smart home.
Nasir, Adnan; Hussain, Syed Imtiaz; Soong, Boon-Hee; Qaraqe, Khalid
2014-09-30
Shrinking water resources all over the world and increasing costs of water consumption have prompted water users and distribution companies to come up with water conserving strategies. We have proposed an energy-efficient smart water monitoring application in [1], using low power RFIDs. In the home environment, there exist many primary interferences within a room, such as cell-phones, Bluetooth devices, TV signals, cordless phones and WiFi devices. In order to reduce the interference from our proposed RFID network for these primary devices, we have proposed a cooperating underlay RFID cognitive network for our smart application on water. These underlay RFIDs should strictly adhere to the interference thresholds to work in parallel with the primary wireless devices [2]. This work is an extension of our previous ventures proposed in [2,3], and we enhanced the previous efforts by introducing a new system model and RFIDs. Our proposed scheme is mutually energy efficient and maximizes the signal-to-noise ratio (SNR) for the RFID link, while keeping the interference levels for the primary network below a certain threshold. A closed form expression for the probability density function (pdf) of the SNR at the destination reader/writer and outage probability are derived. Analytical results are verified through simulations. It is also shown that in comparison to non-cognitive selective cooperation, this scheme performs better in the low SNR region for cognitive networks. Moreover, the hidden Markov model's (HMM) multi-level variant hierarchical hidden Markov model (HHMM) approach is used for pattern recognition and event detection for the data received for this system [4]. Using this model, a feedback and decision algorithm is also developed. This approach has been applied to simulated water pressure data from RFID motes, which were embedded in metallic water pipes.
Energy Efficient Cooperation in Underlay RFID Cognitive Networks for a Water Smart Home
Nasir, Adnan; Hussain, Syed Imtiaz; Soong, Boon-Hee; Qaraqe, Khalid
2014-01-01
Shrinking water resources all over the world and increasing costs of water consumption have prompted water users and distribution companies to come up with water conserving strategies. We have proposed an energy-efficient smart water monitoring application in [1], using low power RFIDs. In the home environment, there exist many primary interferences within a room, such as cell-phones, Bluetooth devices, TV signals, cordless phones and WiFi devices. In order to reduce the interference from our proposed RFID network for these primary devices, we have proposed a cooperating underlay RFID cognitive network for our smart application on water. These underlay RFIDs should strictly adhere to the interference thresholds to work in parallel with the primary wireless devices [2]. This work is an extension of our previous ventures proposed in [2,3], and we enhanced the previous efforts by introducing a new system model and RFIDs. Our proposed scheme is mutually energy efficient and maximizes the signal-to-noise ratio (SNR) for the RFID link, while keeping the interference levels for the primary network below a certain threshold. A closed form expression for the probability density function (pdf) of the SNR at the destination reader/writer and outage probability are derived. Analytical results are verified through simulations. It is also shown that in comparison to non-cognitive selective cooperation, this scheme performs better in the low SNR region for cognitive networks. Moreover, the hidden Markov model’s (HMM) multi-level variant hierarchical hidden Markov model (HHMM) approach is used for pattern recognition and event detection for the data received for this system [4]. Using this model, a feedback and decision algorithm is also developed. This approach has been applied to simulated water pressure data from RFID motes, which were embedded in metallic water pipes. PMID:25271565
The digital revolution in phenotyping
Oellrich, Anika; Collier, Nigel; Groza, Tudor; Rebholz-Schuhmann, Dietrich; Shah, Nigam; Bodenreider, Olivier; Boland, Mary Regina; Georgiev, Ivo; Liu, Hongfang; Livingston, Kevin; Luna, Augustin; Mallon, Ann-Marie; Manda, Prashanti; Robinson, Peter N.; Rustici, Gabriella; Simon, Michelle; Wang, Liqin; Winnenburg, Rainer; Dumontier, Michel
2016-01-01
Phenotypes have gained increased notoriety in the clinical and biological domain owing to their application in numerous areas such as the discovery of disease genes and drug targets, phylogenetics and pharmacogenomics. Phenotypes, defined as observable characteristics of organisms, can be seen as one of the bridges that lead to a translation of experimental findings into clinical applications and thereby support ‘bench to bedside’ efforts. However, to build this translational bridge, a common and universal understanding of phenotypes is required that goes beyond domain-specific definitions. To achieve this ambitious goal, a digital revolution is ongoing that enables the encoding of data in computer-readable formats and the data storage in specialized repositories, ready for integration, enabling translational research. While phenome research is an ongoing endeavor, the true potential hidden in the currently available data still needs to be unlocked, offering exciting opportunities for the forthcoming years. Here, we provide insights into the state-of-the-art in digital phenotyping, by means of representing, acquiring and analyzing phenotype data. In addition, we provide visions of this field for future research work that could enable better applications of phenotype data. PMID:26420780
DIAGNOcam--a Near Infrared Digital Imaging Transillumination (NIDIT) technology.
Abdelaziz, Marwa; Krejci, Ivo
2015-01-01
In developed countries, clinical manifestation of carious lesions is changing: instead of dentists being confronted with wide-open cavities, more and more hidden caries are seen. For a long time, the focus of the research community was on finding a method for the detection of carious lesions without the need for radiographs. The research on Digital Imaging Fiber-Optic Transillumination (DIFOTI) has been an active domain. The scope of the present article is to describe a novel technology for caries diagnostics based on Near Infrared Digital Imaging Transillumination (NIDIT), and to give first examples of its clinical indications. In addition, the coupling of NIDIT with a head-mounted retinal image display (RID) to improve clinical workflow is presented. The novel NIDIT technology was shown to be useful as a diagnostic tool in several indications, including mainly the detection of proximal caries and, less importantly, for occlusal caries, fissures, and secondary decay around amalgam and composite restorations. The coupling of this technology with a head-mounted retinal image system allows for its very efficient implementation into daily practice.
General Method for Constructing Local Hidden Variable Models for Entangled Quantum States
NASA Astrophysics Data System (ADS)
Cavalcanti, D.; Guerini, L.; Rabelo, R.; Skrzypczyk, P.
2016-11-01
Entanglement allows for the nonlocality of quantum theory, which is the resource behind device-independent quantum information protocols. However, not all entangled quantum states display nonlocality. A central question is to determine the precise relation between entanglement and nonlocality. Here we present the first general test to decide whether a quantum state is local, and show that the test can be implemented by semidefinite programing. This method can be applied to any given state and for the construction of new examples of states with local hidden variable models for both projective and general measurements. As applications, we provide a lower-bound estimate of the fraction of two-qubit local entangled states and present new explicit examples of such states, including those that arise from physical noise models, Bell-diagonal states, and noisy Greenberger-Horne-Zeilinger and W states.
Cherepy, Nerine Jane; Payne, Stephen Anthony; Drury, Owen B; Sturm, Benjamin W
2014-11-11
A scintillator radiation detector system according to one embodiment includes a scintillator; and a processing device for processing pulse traces corresponding to light pulses from the scintillator, wherein pulse digitization is used to improve energy resolution of the system. A scintillator radiation detector system according to another embodiment includes a processing device for fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times and performing a direct integration of fit parameters. A method according to yet another embodiment includes processing pulse traces corresponding to light pulses from a scintillator, wherein pulse digitization is used to improve energy resolution of the system. A method in a further embodiment includes fitting digitized scintillation waveforms to an algorithm based on identifying rise and decay times; and performing a direct integration of fit parameters. Additional systems and methods are also presented.
Optical transmission modules for multi-channel superconducting quantum interference device readouts.
Kim, Jin-Mok; Kwon, Hyukchan; Yu, Kwon-kyu; Lee, Yong-Ho; Kim, Kiwoong
2013-12-01
We developed an optical transmission module consisting of 16-channel analog-to-digital converter (ADC), digital-noise filter, and one-line serial transmitter, which transferred Superconducting Quantum Interference Device (SQUID) readout data to a computer by a single optical cable. A 16-channel ADC sent out SQUID readouts data with 32-bit serial data of 8-bit channel and 24-bit voltage data at a sample rate of 1.5 kSample/s. A digital-noise filter suppressed digital noises generated by digital clocks to obtain SQUID modulation as large as possible. One-line serial transmitter reformed 32-bit serial data to the modulated data that contained data and clock, and sent them through a single optical cable. When the optical transmission modules were applied to 152-channel SQUID magnetoencephalography system, this system maintained a field noise level of 3 fT/√Hz @ 100 Hz.
[Digital radiography in young children. Considerations based on experiences in practice].
Berkhout, W E R; Mileman, P A; Weerheijm, K L
2004-10-01
In dentistry, digital radiology techniques, such as a charge-coupled device and a storage phosphor plate, are gaining popularity. It was the objective of this study to assess the importance of the advantages and disadvantages of digital radiology techniques for bitewing radiography in young children, when compared to conventional film. A group of dentists received a questionnaire regarding their experiences with digital radiology techniques or conventional films among young children. Using the Simple Multi-Attributive Rating Technique (SMART) a final weighted score was calculated for the charge-coupled device, the phosphor plate, and conventional film. The scores were 7.40, 7.38, and 6.98 respectively. The differences were not statistically significant (p > 0.47). It could be concluded that, on the basis of experiences in practice, there are no statistically significant preferences for the use of digital radioogy techniques for bitewing radiography in young children.
Millimeterwave and digital applications of InP-based MBE grown HEMTs and HBTs
NASA Astrophysics Data System (ADS)
Greiling, Paul
1997-05-01
Microwave and millimeterwave devices grown by MBE have significantly advanced the state of the art for RF device performance with respect to noise figure, power output, power added efficiency and extended the clock frequency of digital circuits into the millimeterwave regime. Ober the last 10-15 years, military systems have greatly benefited from the superior performance of MBE grown devices. In order to have a similar impact on the commercial marketplace, MBE growers will have to focus their efforts on a different set of performance criteria; i.e. cost, uniformity and reproducibility. This paper discusses outstanding performance achieved by MBE grown devices and outlines the criteria for commercial applications.
Signal processing: opportunities for superconductive circuits
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ralston, R.W.
1985-03-01
Prime motivators in the evolution of increasingly sophisticated communication and detection systems are the needs for handling ever wider signal bandwidths and higher data-processing speeds. These same needs drive the development of electronic device technology. Until recently the superconductive community has been tightly focused on digital devices for high speed computers. The purpose of this paper is to describe opportunities and challenges which exist for both analog and digital devices in a less familiar area, that of wideband signal processing. The function and purpose of analog signal-processing components, including matched filters, correlators and Fourier transformers, will be described and examplesmore » of superconductive implementations given. A canonic signal-processing system is then configured using these components and digital output circuits to highlight the important issues of dynamic range, accuracy and equivalent computation rate. (Reprints)« less
Total Ionizing Dose and Displacement Damage Compendium of Candidate Spacecraft Electronics for NASA
NASA Technical Reports Server (NTRS)
Cochran, Donna J.; Chen, Dakai; Oldham, Timothy R.; Sanders, Anthony B.; Kim, Hak S.; Campola, Michael J.; Buchner, Stephen P.; LaBel, Kenneth A.; Marshall, Cheryl J.; Pellish, Jonathan A.;
2010-01-01
Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.
ERIC Educational Resources Information Center
Hall, Brian R.
2012-01-01
As digital natives continue rolling onto college campuses around the country, the questions surrounding digital ethics grow. Students do not know life without modern technology, computers, mobile devices, the Internet and their lifestyle has developed around this mass. Unlike their predecessors, they do not recognize a difference between the…
Preschool Children and iPads: Observations of Social Interactions during Digital Play
ERIC Educational Resources Information Center
Lawrence, Sandra M.
2018-01-01
Research Findings: Digital play is now commonplace in many young children's lives, but not in preschool settings. This situation is likely due to the fact that the existent literature seldom highlights what digital play looks like, the various ways it can be situated, and what young children do when they play together with digital devices in the…
Reproducible Operating Margins on a 72800-Device Digital Superconducting Chip (Open Access)
2015-10-28
superconductor digital logic. Keywords: flux trapping, yield, digital Superconductor digital technology offers fundamental advantages over conventional...trapping in the superconductor films can degrade or preclude correct circuit operation. Scaling superconductor technology is now possible due to recent...advances in circuit design embodied in reciprocal quantum logic (RQL) [2, 3] and recent advances in superconductor integrated circuit fabrication, which
An Exploratory Study on the Digital Identity Formation of Korean University EFL Learners
ERIC Educational Resources Information Center
Lee, Jang Ho; Kim, Heyoung
2014-01-01
The present study aims to sketch the contours of new media ecology for Korean university students as well as to examine how these learners shape and negotiate their digital identity by using social networking services and digital devices. It also investigates their use of digital media for learning English as a foreign language (EFL). In total,…
Creating the Future of Games and Learning
ERIC Educational Resources Information Center
Squire, Kurt
2015-01-01
Games for learning are poised to enter mainstream education. Several factors driving this movement are the following: (1) Digital distribution through cloud computing services and ubiquitous connectivity which will make digital learning tools--such as games--affordable and easily accessible; (2) The proliferation of digital devices; (3) Digital…
Soil Science in the Digital Age
ERIC Educational Resources Information Center
High, Vance; VanHorn, Laura
2012-01-01
With the pervasiveness of digital technology, elementary students almost instinctively begin inquiry-based instruction with a bias. Visual information from digital devices competes with elementary science inquiry. To counteract this effect, teachers can use advance organizers. The advance organizer is a tool or a mental learning aid to help…
Digital Audio Tape: Yet Another Archival Media?
ERIC Educational Resources Information Center
Vanker, Anthony D.
1989-01-01
Provides an introduction to the technical aspects of digital audiotape and compares it to other computer storage devices such as optical data disks and magnetic tape cartridges in terms of capacity, transfer rate, and cost. The current development of digital audiotape standards is also discussed. (five references) (CLB)
ERIC Educational Resources Information Center
Dickinson, Brady D.
2016-01-01
Providing students with necessary intervention in the instruction of mathematics can be accomplished through the use of digital resources. Schools reaching a one-to-one (one device for every student) status have the ability to implement a digital intervention on a broad scale. For the purpose of this study, mixed methods research afforded an…
ERIC Educational Resources Information Center
Mechling, Linda C.; Gast, David L.; Seid, Nicole H.
2010-01-01
The purpose of this study was to evaluate whether the use of a personal digital assistant (PDA), with picture, auditory, and video prompts, would serve as a portable self-prompting device to facilitate independent task performance by high school age students with moderate intellectual disabilities. A multiple probe design was used across three…
Torous, J; Onnela, J-P; Keshavan, M
2017-03-07
Mobile and connected devices like smartphones and wearable sensors can facilitate the collection of novel naturalistic and longitudinal data relevant to psychiatry at both the personal and population level. The National Institute of Mental Health's Research Domain Criteria framework offers a useful roadmap to organize, guide and lead new digital phenotyping data towards research discoveries and clinical advances.
BPSK Demodulation Using Digital Signal Processing
NASA Technical Reports Server (NTRS)
Garcia, Thomas R.
1996-01-01
A digital communications signal is a sinusoidal waveform that is modified by a binary (digital) information signal. The sinusoidal waveform is called the carrier. The carrier may be modified in amplitude, frequency, phase, or a combination of these. In this project a binary phase shift keyed (BPSK) signal is the communication signal. In a BPSK signal the phase of the carrier is set to one of two states, 180 degrees apart, by a binary (i.e., 1 or 0) information signal. A digital signal is a sampled version of a "real world" time continuous signal. The digital signal is generated by sampling the continuous signal at discrete points in time. The rate at which the signal is sampled is called the sampling rate (f(s)). The device that performs this operation is called an analog-to-digital (A/D) converter or a digitizer. The digital signal is composed of the sequence of individual values of the sampled BPSK signal. Digital signal processing (DSP) is the modification of the digital signal by mathematical operations. A device that performs this processing is called a digital signal processor. After processing, the digital signal may then be converted back to an analog signal using a digital-to-analog (D/A) converter. The goal of this project is to develop a system that will recover the digital information from a BPSK signal using DSP techniques. The project is broken down into the following steps: (1) Development of the algorithms required to demodulate the BPSK signal; (2) Simulation of the system; and (3) Implementation a BPSK receiver using digital signal processing hardware.
Rapid Prototyping of a Smart Device-based Wireless Reflectance Photoplethysmograph
Ghamari, M.; Aguilar, C.; Soltanpur, C.; Nazeran, H.
2017-01-01
This paper presents the design, fabrication, and testing of a wireless heart rate (HR) monitoring device based on photoplethysmography (PPG) and smart devices. PPG sensors use infrared (IR) light to obtain vital information to assess cardiac health and other physiologic conditions. The PPG data that are transferred to a computer undergo further processing to derive the Heart Rate Variability (HRV) signal, which is analyzed to generate quantitative markers of the Autonomic Nervous System (ANS). The HRV signal has numerous monitoring and diagnostic applications. To this end, wireless connectivity plays an important role in such biomedical instruments. The photoplethysmograph consists of an optical sensor to detect the changes in the light intensity reflected from the illuminated tissue, a signal conditioning unit to prepare the reflected light for further signal conditioning through amplification and filtering, a low-power microcontroller to control and digitize the analog PPG signal, and a Bluetooth module to transmit the digital data to a Bluetooth-based smart device such as a tablet. An Android app is then used to enable the smart device to acquire and digitally display the received analog PPG signal in real-time on the smart device. This article is concluded with the prototyping of the wireless PPG followed by the verification procedures of the PPG and HRV signals acquired in a laboratory environment. PMID:28959119
Rapid Prototyping of a Smart Device-based Wireless Reflectance Photoplethysmograph.
Ghamari, M; Aguilar, C; Soltanpur, C; Nazeran, H
2016-03-01
This paper presents the design, fabrication, and testing of a wireless heart rate (HR) monitoring device based on photoplethysmography (PPG) and smart devices. PPG sensors use infrared (IR) light to obtain vital information to assess cardiac health and other physiologic conditions. The PPG data that are transferred to a computer undergo further processing to derive the Heart Rate Variability (HRV) signal, which is analyzed to generate quantitative markers of the Autonomic Nervous System (ANS). The HRV signal has numerous monitoring and diagnostic applications. To this end, wireless connectivity plays an important role in such biomedical instruments. The photoplethysmograph consists of an optical sensor to detect the changes in the light intensity reflected from the illuminated tissue, a signal conditioning unit to prepare the reflected light for further signal conditioning through amplification and filtering, a low-power microcontroller to control and digitize the analog PPG signal, and a Bluetooth module to transmit the digital data to a Bluetooth-based smart device such as a tablet. An Android app is then used to enable the smart device to acquire and digitally display the received analog PPG signal in real-time on the smart device. This article is concluded with the prototyping of the wireless PPG followed by the verification procedures of the PPG and HRV signals acquired in a laboratory environment.
Rotary encoding device with polygonal reflector and centroid detection
NASA Technical Reports Server (NTRS)
Leviton, Douglas B. (Inventor)
1994-01-01
A device for positioning encoding of a rotating shaft in which a polygonal mirror having a number of facets is mounted to the shaft and a light beam is directed towards the facets. The facets of the polygonal mirror reflect the light beam such that a light spot is created on a linear array detector. An analog-to-digital converter is connected to the linear array detector for reading the position of the spot on the spots on the linear array detector. A microprocessor with memory is connected to the analog-to-digital converter to hold and manipulate the data provided by the analog-to-digital converter on the position of the spot and to compute the position of the shaft based upon the data from the analog-to-digital converter.
NASA Technical Reports Server (NTRS)
Leviton, Douglas B. (Inventor)
1993-01-01
A Linear Motion Encoding device for measuring the linear motion of a moving object is disclosed in which a light source is mounted on the moving object and a position sensitive detector such as an array photodetector is mounted on a nearby stationary object. The light source emits a light beam directed towards the array photodetector such that a light spot is created on the array. An analog-to-digital converter, connected to the array photodetector is used for reading the position of the spot on the array photodetector. A microprocessor and memory is connected to the analog-to-digital converter to hold and manipulate data provided by the analog-to-digital converter on the position of the spot and to compute the linear displacement of the moving object based upon the data from the analog-to-digital converter.
Digital gate pulse generator for cycloconverter control
Klein, Frederick F.; Mutone, Gioacchino A.
1989-01-01
The present invention provides a digital gate pulse generator which controls the output of a cycloconverter used for electrical power conversion applications by determining the timing and delivery of the firing pulses to the switching devices in the cycloconverter. Previous gate pulse generators have been built with largely analog or discrete digital circuitry which require many precision components and periodic adjustment. The gate pulse generator of the present invention utilizes digital techniques and a predetermined series of values to develop the necessary timing signals for firing the switching device. Each timing signal is compared with a reference signal to determine the exact firing time. The present invention is significantly more compact than previous gate pulse generators, responds quickly to changes in the output demand and requires only one precision component and no adjustments.
Development of a low-frequency physiotherapeutic device for diabetes manipulated by microcontroller.
Guo, Jin-Song; Gong, Jian
2001-01-01
OBJECTIVE: To develop a physiotherapeutic device for diabetes that generates special low-frequency waveform manipulated by a microcontroller. METHODS: A microcontoller and a digital-to-analog converter were utilized along with a keyboard and LED display circuit, to generate desired low-frequecy waveform with the assistance of a software. RESULTS: The complex waveform generated by this device met the demands for diabetes physiotherapy, and the frequency and amplitude could be freely adjusted. CONCLUSIONS: The utilization of a digital-to-analog converter controlled by a microcontroller can very well serve the purpose of a low-frequency physiotherapy for diabetes.
"Off Label" Use of FDA-Approved Devices and Digital Breast Tomosynthesis.
Kopans, Daniel B
2015-11-01
The purpose of this article is to clarify for radiologists the meaning of U.S. Food and Drug Administration (FDA) approval with respect to Digital Breast Tomosynthesis (DBT). DBT is a major improvement over 2D mammography in the detection of cancers (sensitivity) and the reduction in recalls resulting from screening (specificity). Most imaging systems that have been approved by the FDA are used "off label" for breast imaging. Although the FDA determines which claims a manufacturer can make for a device, physicians may use approved devices, such as DBT, off label to provide better patient care.
Salazar-Gamarra, Rodrigo; Seelaus, Rosemary; da Silva, Jorge Vicente Lopes; da Silva, Airton Moreira; Dib, Luciano Lauria
2016-05-25
The aim of this study is to present the development of a new technique to obtain 3D models using photogrammetry by a mobile device and free software, as a method for making digital facial impressions of patients with maxillofacial defects for the final purpose of 3D printing of facial prostheses. With the use of a mobile device, free software and a photo capture protocol, 2D captures of the anatomy of a patient with a facial defect were transformed into a 3D model. The resultant digital models were evaluated for visual and technical integrity. The technical process and resultant models were described and analyzed for technical and clinical usability. Generating 3D models to make digital face impressions was possible by the use of photogrammetry with photos taken by a mobile device. The facial anatomy of the patient was reproduced by a *.3dp and a *.stl file with no major irregularities. 3D printing was possible. An alternative method for capturing facial anatomy is possible using a mobile device for the purpose of obtaining and designing 3D models for facial rehabilitation. Further studies must be realized to compare 3D modeling among different techniques and systems. Free software and low cost equipment could be a feasible solution to obtain 3D models for making digital face impressions for maxillofacial prostheses, improving access for clinical centers that do not have high cost technology considered as a prior acquisition.
NASA Astrophysics Data System (ADS)
Lin, Shengmin; Lin, Chi-Pin; Wang, Weng-Lyang; Hsiao, Feng-Ke; Sikora, Robert
2009-08-01
A 256x512 element digital image sensor has been developed which has a large pixel size, slow scan and low power consumption for Hyper Spectral Imager (HySI) applications. The device is a mixed mode, silicon on chip (SOC) IC. It combines analog circuitry, digital circuitry and optical sensor circuitry into a single chip. This chip integrates a 256x512 active pixel sensor array, a programming gain amplifier (PGA) for row wise gain setting, I2C interface, SRAM, 12 bit analog to digital convertor (ADC), voltage regulator, low voltage differential signal (LVDS) and timing generator. The device can be used for 256 pixels of spatial resolution and 512 bands of spectral resolution ranged from 400 nm to 950 nm in wavelength. In row wise gain readout mode, one can set a different gain on each row of the photo detector by storing the gain setting data on the SRAM thru the I2C interface. This unique row wise gain setting can be used to compensate the silicon spectral response non-uniformity problem. Due to this unique function, the device is suitable for hyper-spectral imager applications. The HySI camera located on-board the Chandrayaan-1 satellite, was successfully launched to the moon on Oct. 22, 2008. The device is currently mapping the moon and sending back excellent images of the moon surface. The device design and the moon image data will be presented in the paper.
Digital LAMP in a sample self-digitization (SD) chip
Herrick, Alison M.; Dimov, Ivan K.; Lee, Luke P.; Chiu, Daniel T.
2012-01-01
This paper describes the realization of digital loop-mediated DNA amplification (dLAMP) in a sample self-digitization (SD) chip. Digital DNA amplification has become an attractive technique to quantify absolute concentrations of DNA in a sample. While digital polymerase chain reaction is still the most widespread implementation, its use in resource—limited settings is impeded by the need for thermal cycling and robust temperature control. In such situations, isothermal protocols that can amplify DNA or RNA without thermal cycling are of great interest. Here, we showed the successful amplification of single DNA molecules in a stationary droplet array using isothermal digital loop-mediated DNA amplification. Unlike most (if not all) existing methods for sample discretization, our design allows for automated, loss-less digitization of sample volumes on-chip. We demonstrated accurate quantification of relative and absolute DNA concentrations with sample volumes of less than 2 μl. We assessed the homogeneity of droplet size during sample self-digitization in our device, and verified that the size variation was small enough such that straightforward counting of LAMP-active droplets sufficed for data analysis. We anticipate that the simplicity and robustness of our SD chip make it attractive as an inexpensive and easy-to-operate device for DNA amplification, for example in point-of-care settings. PMID:22399016
Digital microfluidic platform for radiochemistry
Van Dam, Michael R.; Kim, Chang-Jin; Chen, Supin; Ding, Huijiang; Shah, Gaurav Jitendra; Keng, Pei Yuin
2016-11-01
Disclosed herein are methods of performing microchemical reactions and electro-wetting-on-dielectric devices (EWOD devices) for use in performing those reactions. These devices and method are particularly suited for preparing radiochemical compounds, particularly compounds containing .sup.18F.
Digital microfluidic platform for radiochemistry
Van Dam, R. Michael; Kim, Chang -Jin; Chen, Supin; Ding, Huijiang; Shah, Gaurav Jitendra; Keng, Pei Yuin
2015-11-24
Disclosed herein are methods of performing microchemical reactions and electro-wetting-on-dielectric devices (EWOD devices) for use in performing those reactions. These devices and method are particularly suited for preparing radiochemical compounds, particularly compounds containing .sup.18F.
NASA Technical Reports Server (NTRS)
Cochran, Donna J.; Boutte, Alvin J.; Campola, Michael J.; Carts, Martin A.; Casey, Megan C.; Chen, Dakai; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Marshall, Cheryl J.;
2011-01-01
Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.
Instruments speak global language
DOE Office of Scientific and Technical Information (OSTI.GOV)
Nudo, L.
1993-07-01
If all goes as planned, companies that use instruments for measurement and control will get more complete, reliable and repeatable information about their processes with advanced digital devices that speak a global language. That language, in technical terms, is known as international fieldbus. But it's not much different from English's role as the international language of business. Companies that use a remote measurement device for environmental applications, such as pH control and fugitive emissions control, are candidates for fieldbus devices, which are much faster and measure more process variables than their counterpart analog devices. With the advent of a globalmore » fieldbus, users will see digital valves, solenoids and multivariable transmitters. Fieldbus technology redefines the roles of the control system and field devices. The control system still serves as a central clearinghouse, but field devices will handle more control and reporting functions and generate data that can be used for trending and preventive maintenance.« less
Caranguian, Luther Paul R; Pancho-Festin, Susan; Sison, Luis G
2012-01-01
In this study, we focused on the interoperability and authentication of medical devices in the context of telemedical systems. A recent standard called the ISO/IEEE 11073 Personal Health Device (X73-PHD) Standards addresses the device interoperability problem by defining common protocols for agent (medical device) and manager (appliance) interface. The X73-PHD standard however has not addressed security and authentication of medical devices which is important in establishing integrity of a telemedical system. We have designed and implemented a security policy within the X73-PHD standards. The policy will enable device authentication using Asymmetric-Key Cryptography and the RSA algorithm as the digital signature scheme. We used two approaches for performing the digital signatures: direct software implementation and use of embedded security modules (ESM). The two approaches were evaluated and compared in terms of execution time and memory requirement. For the standard 2048-bit RSA, ESM calculates digital signatures only 12% of the total time for the direct implementation. Moreover, analysis shows that ESM offers more security advantage such as secure storage of keys compared to using direct implementation. Interoperability with other systems was verified by testing the system with LNI Healthlink, a manager software that implements the X73-PHD standard. Lastly, security analysis was done and the system's response to common attacks on authentication systems was analyzed and several measures were implemented to protect the system against them.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-03
...-Exclusive Licenses: Multi-Focal Structured Illumination Microscopy Systems and Methods AGENCY: National... pertains to a system and method for digital confocal microscopy that rapidly processes enhanced images. In particular, the invention is a method for digital confocal microscopy that includes a digital mirror device...
Doppler extraction with a digital VCO
NASA Technical Reports Server (NTRS)
Starner, E. R.; Nossen, E. J.
1977-01-01
Digitally controlled oscillator in phased-locked loop may be useful for data communications systems, or may be modified to serve as information extraction component of microwave or optical system for collision avoidance or automatic braking. Instrument is frequency-synthesizing device with output specified precisely by digital number programmed into frequency register.
Digital Literacy: Tools and Methodologies for Information Society
ERIC Educational Resources Information Center
Rivoltella, Pier Cesare, Ed.
2008-01-01
Currently in a state of cultural transition, global society is moving from a literary society to digital one, adopting widespread use of advanced technologies such as the Internet and mobile devices. Digital media has an extraordinary impact on society's formative processes, forcing a pragmatic shift in their management and organization. This…
ERIC Educational Resources Information Center
Gourlay, Lesley; Lanclos, Donna M.; Oliver, Martin
2015-01-01
Work on students' study practices posits the digital and material as separate domains, with the "digital" assumed to be disembodied, decontextualised and free-floating, and spaces in the material campus positioned as prototypically "traditional" and analogue. Libraries in particular are often characterised as symbolic of…
Interactive Digital Textbooks and Engagement: A Learning Strategies Framework
ERIC Educational Resources Information Center
Bikowski, Dawn; Casal, J. Elliott
2018-01-01
This mixed-methods study explored non-native English speaking students' learning processes and engagement as they used a customized interactive digital textbook housed on a mobile device. Think aloud protocols, surveys of anticipated and actual engagement with the digital textbook, reflective journals, and member checking constituted data…
The role of digital data entry in participatory environmental monitoring.
Brammer, Jeremy R; Brunet, Nicolas D; Burton, A Cole; Cuerrier, Alain; Danielsen, Finn; Dewan, Kanwaljeet; Herrmann, Thora Martina; Jackson, Micha V; Kennett, Rod; Larocque, Guillaume; Mulrennan, Monica; Pratihast, Arun Kumar; Saint-Arnaud, Marie; Scott, Colin; Humphries, Murray M
2016-12-01
Many argue that monitoring conducted exclusively by scientists is insufficient to address ongoing environmental challenges. One solution entails the use of mobile digital devices in participatory monitoring (PM) programs. But how digital data entry affects programs with varying levels of stakeholder participation, from nonscientists collecting field data to nonscientists administering every step of a monitoring program, remains unclear. We reviewed the successes, in terms of management interventions and sustainability, of 107 monitoring programs described in the literature (hereafter programs) and compared these with case studies from our PM experiences in Australia, Canada, Ethiopia, Ghana, Greenland, and Vietnam (hereafter cases). Our literature review showed that participatory programs were less likely to use digital devices, and 2 of our 3 more participatory cases were also slow to adopt digital data entry. Programs that were participatory and used digital devices were more likely to report management actions, which was consistent with cases in Ethiopia, Greenland, and Australia. Programs engaging volunteers were more frequently reported as ongoing, but those involving digital data entry were less often sustained when data collectors were volunteers. For the Vietnamese and Canadian cases, sustainability was undermined by a mismatch in stakeholder objectives. In the Ghanaian case, complex field protocols diminished monitoring sustainability. Innovative technologies attract interest, but the foundation of effective participatory adaptive monitoring depends more on collaboratively defined questions, objectives, conceptual models, and monitoring approaches. When this foundation is built through effective partnerships, digital data entry can enable the collection of more data of higher quality. Without this foundation, or when implemented ineffectively or unnecessarily, digital data entry can be an additional expense that distracts from core monitoring objectives and undermines project sustainability. The appropriate role of digital data entry in PM likely depends more on the context in which it is used and less on the technology itself. © 2016 Society for Conservation Biology.
Programming Wireless Handheld Devices for Applications in Teaching Astronomy
NASA Astrophysics Data System (ADS)
Budiardja, R.; Saranathan, V.; Guidry, M.
2002-12-01
Wireless technology implemented with handheld devices has attractive features because of the potential to access large amounts of data and the prospect of on-the-fly computational analysis from a device that can be carried in a shirt pocket. We shall describe applications of such technology to the general paradigm of making digital wireless connections from the field to upload information and queries to network servers, executing (potentially complex) data analysis and/or database operations on fast network computers, and returning real-time information from this analysis to the handheld device in the field. As illustration, we shall describe several client/server programs that we have written for applications in teaching introductory astronomy. For example, one program allows static and dynamic properties of astronomical objects to be accessed in a remote observation laboratory setting using a digital cell phone or PDA. Another implements interactive quizzing over a cell phone or PDA using a 700-question introductory astronomy quiz database, thus permitting students to study for astronomy quizzes in any environment in which they have a few free minutes and a digital cell phone or wireless PDA. The presentation will include hands-on demonstrations with real devices.
Calculation for simulation of archery goal value using a web camera and ultrasonic sensor
NASA Astrophysics Data System (ADS)
Rusjdi, Darma; Abdurrasyid, Wulandari, Dewi Arianti
2017-08-01
Development of the device simulator digital indoor archery-based embedded systems as a solution to the limitations of the field or open space is adequate, especially in big cities. Development of the device requires simulations to calculate the value of achieving the target based on the approach defined by the parabolic motion variable initial velocity and direction of motion of the arrow reaches the target. The simulator device should be complemented with an initial velocity measuring device using ultrasonic sensors and measuring direction of the target using a digital camera. The methodology uses research and development of application software from modeling and simulation approach. The research objective to create simulation applications calculating the value of the achievement of the target arrows. Benefits as a preliminary stage for the development of the simulator device of archery. Implementation of calculating the value of the target arrows into the application program generates a simulation game of archery that can be used as a reference development of the digital archery simulator in a room with embedded systems using ultrasonic sensors and web cameras. Applications developed with the simulation calculation comparing the outer radius of the circle produced a camera from a distance of three meters.
Uses of megavoltage digital tomosynthesis in radiotherapy
NASA Astrophysics Data System (ADS)
Sarkar, Vikren
With the advent of intensity modulated radiotherapy, radiation treatment plans are becoming more conformal to the tumor with the decreasing margins. It is therefore of prime importance that the patient be positioned correctly prior to treatment. Therefore, image guided treatment is necessary for intensity modulated radiotherapy plans to be implemented successfully. Current advanced imaging devices require costly hardware and software upgrade, and radiation imaging solutions, such as cone beam computed tomography, may introduce extra radiation dose to the patient in order to acquire better quality images. Thus, there is a need to extend current existing imaging device ability and functions while reducing cost and radiation dose. Existing electronic portal imaging devices can be used to generate computed tomography-like tomograms through projection images acquired over a small angle using the technique of cone-beam digital tomosynthesis. Since it uses a fraction of the images required for computed tomography reconstruction, use of this technique correspondingly delivers only a fraction of the imaging dose to the patient. Furthermore, cone-beam digital tomosynthesis can be offered as a software-only solution as long as a portal imaging device is available. In this study, the feasibility of performing digital tomosynthesis using individually-acquired megavoltage images from a charge coupled device-based electronic portal imaging device was investigated. Three digital tomosynthesis reconstruction algorithms, the shift-and-add, filtered back-projection, and simultaneous algebraic reconstruction technique, were compared considering the final image quality and radiation dose during imaging. A software platform, DART, was created using a combination of the Matlab and C++ languages. The platform allows for the registration of a reference Cone Beam Digital Tomosynthesis (CBDT) image against a daily acquired set to determine how to shift the patient prior to treatment. Finally, the software was extended to investigate if the digital tomosynthesis dataset could be used in an adaptive radiotherapy regimen through the use of the Pinnacle treatment planning software to recalculate dose delivered. The feasibility study showed that the megavoltage CBDT visually agreed with corresponding megavoltage computed tomography images. The comparative study showed that the best compromise between imaging quality and imaging dose is obtained when 11 projection images, acquired over an imaging angle of 40°, are used with the filtered back-projection algorithm. DART was successfully used to register reference and daily image sets to within 1 mm in-plane and 2.5 mm out of plane. The DART platform was also effectively used to generate updated files that the Pinnacle treatment planning system used to calculate updated dose in a rigidly shifted patient. These doses were then used to calculate a cumulative dose distribution that could be used by a physician as reference to decide when the treatment plan should be updated. In conclusion, this study showed that a software solution is possible to extend existing electronic portal imaging devices to function as cone-beam digital tomosynthesis devices and achieve daily requirement for image guided intensity modulated radiotherapy treatments. The DART platform also has the potential to be used as a part of adaptive radiotherapy solution.
Kevat, Ajay C; Kalirajah, Anaath; Roseby, Robert
2017-07-01
Our study aimed to objectively describe the audiological characteristics of wheeze and crackles in children by using digital stethoscope (DS) auscultation, as well as assess concordance between standard auscultation and two different DS devices in their ability to detect pathological breath sounds. Twenty children were auscultated by a paediatric consultant doctor and digitally recorded using the Littman™ 3200 Digital Electronic Stethoscope and a Clinicloud™ DS with smart device. Using spectrographic analysis, we found those with clinically described wheeze had prominent periodic waveform segments spanning expiration for a period of 0.03-1.2 s at frequencies of 100-1050 Hz, and occasionally spanning shorter inspiratory segments; paediatric crackles were brief discontinuous sounds with a distinguishing waveform. There was moderate concordance with respect to wheeze detection between digital and standard binaural stethoscopes, and 100% concordance for crackle detection. Importantly, DS devices were more sensitive than clinician auscultation in detecting wheeze in our study. Objective definition of audio characteristics of abnormal paediatric breath sounds was achieved using DS technology. We demonstrated superiority of our DS method compared to traditional auscultation for detection of wheeze. What is Known: • The audiological characteristics of abnormal breath sounds have been well-described in adult populations but not in children. • Inter-observer agreement for detection of pathological breath sounds using standard auscultation has been shown to be poor, but the clinical value of now easily available digital stethoscopes has not been sufficiently examined. What is New: • Digital stethoscopes can objectively define the nature of pathological breath sounds such as wheeze and crackles in children. • Paediatric wheeze was better detected by digital stethoscopes than by standard auscultation performed by an expert paediatric clinician.
Tu, Junchao; Zhang, Liyan
2018-01-12
A new solution to the problem of galvanometric laser scanning (GLS) system calibration is presented. Under the machine learning framework, we build a single-hidden layer feedforward neural network (SLFN)to represent the GLS system, which takes the digital control signal at the drives of the GLS system as input and the space vector of the corresponding outgoing laser beam as output. The training data set is obtained with the aid of a moving mechanism and a binocular stereo system. The parameters of the SLFN are efficiently solved in a closed form by using extreme learning machine (ELM). By quantitatively analyzing the regression precision with respective to the number of hidden neurons in the SLFN, we demonstrate that the proper number of hidden neurons can be safely chosen from a broad interval to guarantee good generalization performance. Compared to the traditional model-driven calibration, the proposed calibration method does not need a complex modeling process and is more accurate and stable. As the output of the network is the space vectors of the outgoing laser beams, it costs much less training time and can provide a uniform solution to both laser projection and 3D-reconstruction, in contrast with the existing data-driven calibration method which only works for the laser triangulation problem. Calibration experiment, projection experiment and 3D reconstruction experiment are respectively conducted to test the proposed method, and good results are obtained.
ERIC Educational Resources Information Center
Gogia, Laura Park
2016-01-01
Virginia Commonwealth University (VCU) is implementing a large scale exploration of digital pedagogies, including connected learning and open education, in an effort to promote digital fluency and integrative thinking among students. The purpose of this study was to develop a classroom assessment toolkit for faculty who wish to document student…
NASA Astrophysics Data System (ADS)
Valiya Peedikakkal, Liyana; Steventon, Victoria; Furley, Andrew; Cadby, Ashley J.
2017-12-01
We demonstrate a simple illumination system based on a digital mirror device which allows for fine control over the power and pattern of illumination. We apply this to localization microscopy (LM), specifically stochastic optical reconstruction microscopy (STORM). Using this targeted STORM, we were able to image a selected area of a labelled cell without causing photo-damage to the surrounding areas of the cell.
Electronics for Deep Space Cryogenic Applications
NASA Technical Reports Server (NTRS)
Patterson, R. L.; Hammond, A.; Dickman, J. E.; Gerber, S. S.; Elbuluk, M. E.; Overton, E.
2002-01-01
Deep space probes and planetary exploration missions require electrical power management and control systems that are capable of efficient and reliable operation in very cold temperature environments. Typically, in deep space probes, heating elements are used to keep the spacecraft electronics near room temperature. The utilization of power electronics designed for and operated at low temperature will contribute to increasing efficiency and improving reliability of space power systems. At NASA Glenn Research Center, commercial-off-the-shelf devices as well as developed components are being investigated for potential use at low temperatures. These devices include semiconductor switching devices, magnetics, and capacitors. Integrated circuits such as digital-to-analog and analog-to-digital converters, DC/DC converters, operational amplifiers, and oscillators are also being evaluated. In this paper, results will be presented for selected analog-to-digital converters, oscillators, DC/DC converters, and pulse width modulation (PWM) controllers.
Some reflections upon Internet TV in the Brazilian context
NASA Astrophysics Data System (ADS)
de Lima-Lopes, Rodrigo
2016-10-01
Negroponte [1996. Being digital (1st ed.). New York, NY: Vintage Books] discusses the migration television might take from its air-based broadcasting to the digital environment. This paper takes into consideration the exercise in futurology made by Negroponte [1996. Being digital (1st ed.). New York, NY: Vintage Books] as an inspiration to discuss which Internet TV models are currently adopted in Brazil. They are studied in terms of the platforms used and the nature of the channels available. Results show that a number of devices can be used for Internet TV; some channels are redundant, since they are present in more than one context. There are a number of foreign (broadcasting in their own language) and Brazilian channels that seem to be exclusive in each device. Due to the price of some devices, as well as some issues regarding connectivity in Brazil, some platforms seem to lack local production.
NASA Technical Reports Server (NTRS)
Cochran, Donna J.; O'Bryan, Martha V.; Buchner, Stephen P.; Poivey, Christian; Ladbury, Ray L.; LaBel, Kenneth A.
2007-01-01
Sensitivity of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.
21 CFR 872.3661 - Optical Impression Systems for CAD/CAM.
Code of Federal Regulations, 2011 CFR
2011-04-01
... (CONTINUED) MEDICAL DEVICES DENTAL DEVICES Prosthetic Devices § 872.3661 Optical Impression Systems for CAD... (CAD/CAM) is a device used to record the topographical characteristics of teeth, dental impressions, or stone models by analog or digital methods for use in the computer-assisted design and manufacturing of...
Miner, Sarah; Sterling, Mark; Halterman, Jill S; Fairbanks, Eileen
2014-01-01
Background Many adolescents suffer serious asthma related morbidity that can be prevented by adequate self-management of the disease. The accurate symptom monitoring by patients is the most fundamental antecedent to effective asthma management. Nonetheless, the adequacy and effectiveness of current methods of symptom self-monitoring have been challenged due to the individuals’ fallible symptom perception, poor adherence, and inadequate technique. Recognition of these limitations led to the development of an innovative device that can facilitate continuous and accurate monitoring of asthma symptoms with minimal disruption of daily routines, thus increasing acceptability to adolescents. Objective The objectives of this study were to: (1) describe the development of a novel symptom monitoring device for teenagers (teens), and (2) assess their perspectives on the usability and acceptability of the device. Methods Adolescents (13-17 years old) with and without asthma participated in the evolution of an automated device for asthma monitoring (ADAM), which comprised three phases, including development (Phase 1, n=37), validation/user acceptability (Phase 2, n=84), and post hoc validation (Phase 3, n=10). In Phase 1, symptom algorithms were identified based on the acoustic analysis of raw symptom sounds and programmed into a popular mobile system, the iPod. Phase 2 involved a 7 day trial of ADAM in vivo, and the evaluation of user acceptance using an acceptance survey and individual interviews. ADAM was further modified and enhanced in Phase 3. Results Through ADAM, incoming audio data were digitized and processed in two steps involving the extraction of a sequence of descriptive feature vectors, and the processing of these sequences by a hidden Markov model-based Viterbi decoder to differentiate symptom sounds from background noise. The number and times of detected symptoms were stored and displayed in the device. The sensitivity (true positive) of the updated cough algorithm was 70% (21/30), and, on average, 2 coughs per hour were identified as false positive. ADAM also kept track of the their activity level throughout the day using the mobile system’s built in accelerometer function. Overall, the device was well received by participants who perceived it as attractive, convenient, and helpful. The participants recognized the potential benefits of the device in asthma care, and were eager to use it for their asthma management. Conclusions ADAM can potentially automate daily symptom monitoring with minimal intrusiveness and maximal objectivity. The users’ acceptance of the device based on its recognized convenience, user-friendliness, and usefulness in increasing symptom awareness underscores ADAM’s potential to overcome the issues of symptom monitoring including poor adherence, inadequate technique, and poor symptom perception in adolescents. Further refinement of the algorithm is warranted to improve the accuracy of the device. Future study is also needed to assess the efficacy of the device in promoting self-management and asthma outcomes. PMID:25100184
Thin, nearly wireless adaptive optical device
NASA Technical Reports Server (NTRS)
Knowles, Gareth (Inventor); Hughes, Eli (Inventor)
2008-01-01
A thin, nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.
Thin, nearly wireless adaptive optical device
NASA Technical Reports Server (NTRS)
Knowles, Gareth (Inventor); Hughes, Eli (Inventor)
2007-01-01
A thin, nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.
Thin nearly wireless adaptive optical device
NASA Technical Reports Server (NTRS)
Knowles, Gareth J. (Inventor); Hughes, Eli (Inventor)
2009-01-01
A thin nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.
Oliveira, Gisele; Fava, Gaetano; Baglione, Melody; Pimpinella, Michael
2017-03-01
To determine whether the iRig and iOS device recording system is comparable with a standard computer recording system for digital voice recording. Thirty-seven vocally healthy adults, between ages 20 and 62, with a mean age of 33.9 years, 13 males and 24 females, were recruited. Recordings were simultaneously digitalized in an iPad and iPhone using a unidirectional condenser microphone for smartphones/tablets (iRig Mic, IK Multimedia) and in a computer laptop (Dell-Inspiron) using a unidirectional condenser microphone (Samson-CL5) connected to a preamplifier with phantom power. Both microphones were lined up at an equal fixed distance from the subject's mouth. Speech tasks consisted of a sustained vowel "ah" at comfortable pitch/loudness, counting from 1 to 10, and a glissando "ah" from a low to a high note. The samples captured on the iOS devices were transferred via SoundCloud in WAV format, and analyzed using the Praat software. The acoustic parameters measured were mean, min, and max F0, SD F0, jitter local, jitter rap, jitter ppq5, jitter ddp, shimmer local, shimmer local-dB, shimmer apq3, shimmer apq5, shimmer apq11, shimmer dda, NHR, and HNR. There were no statistically significant differences for any parameter and speech task analyzed for both iOS devices as compared with the gold standard computer/preamp system (all P values > 0.050). In addition, there were no statistical differences in the perceptual identification of the recordings among devices (P < 0.001). In the present study, the iRig and iOS device may provide reliable digital recording of normal voices. Copyright © 2017 The Voice Foundation. Published by Elsevier Inc. All rights reserved.
Interactive 2D to 3D stereoscopic image synthesis
NASA Astrophysics Data System (ADS)
Feldman, Mark H.; Lipton, Lenny
2005-03-01
Advances in stereoscopic display technologies, graphic card devices, and digital imaging algorithms have opened up new possibilities in synthesizing stereoscopic images. The power of today"s DirectX/OpenGL optimized graphics cards together with adapting new and creative imaging tools found in software products such as Adobe Photoshop, provide a powerful environment for converting planar drawings and photographs into stereoscopic images. The basis for such a creative process is the focus of this paper. This article presents a novel technique, which uses advanced imaging features and custom Windows-based software that utilizes the Direct X 9 API to provide the user with an interactive stereo image synthesizer. By creating an accurate and interactive world scene with moveable and flexible depth map altered textured surfaces, perspective stereoscopic cameras with both visible frustums and zero parallax planes, a user can precisely model a virtual three-dimensional representation of a real-world scene. Current versions of Adobe Photoshop provide a creative user with a rich assortment of tools needed to highlight elements of a 2D image, simulate hidden areas, and creatively shape them for a 3D scene representation. The technique described has been implemented as a Photoshop plug-in and thus allows for a seamless transition of these 2D image elements into 3D surfaces, which are subsequently rendered to create stereoscopic views.
Leadership, Ethics and Law of War. Discussion Guide for Marines
2008-01-01
confinement for using his military working dog to scare detainees. 2 Jun Dog handler SGT Cardona is sentence to ninety days hard labor without...weapons openly. While pretending to be civilians they slaughtered countless American troops using mines, improvised explosive devices, and other hidden...America’s young people were caught up in a counter-culture movement that rejected authority at every level and embraced a lifestyle that incorporated use
Where-Fi: a dynamic energy-efficient multimedia distribution framework for MANETs
NASA Astrophysics Data System (ADS)
Mohapatra, Shivajit; Carbunar, Bogdan; Pearce, Michael; Chaudhri, Rohit; Vasudevan, Venu
2008-01-01
Next generation mobile ad-hoc applications will revolve around users' need for sharing content/presence information with co-located devices. However, keeping such information fresh requires frequent meta-data exchanges, which could result in significant energy overheads. To address this issue, we propose distributed algorithms for energy efficient dissemination of presence and content usage information between nodes in mobile ad-hoc networks. First, we introduce a content dissemination protocol (called CPMP) for effectively distributing frequent small meta-data updates between co-located devices using multicast. We then develop two distributed algorithms that use the CPMP protocol to achieve "phase locked" wake up cycles for all the participating nodes in the network. The first algorithm is designed for fully-connected networks and then extended in the second to handle hidden terminals. The "phase locked" schedules are then exploited to adaptively transition the network interface to a deep sleep state for energy savings. We have implemented a prototype system (called "Where-Fi") on several Motorola Linux-based cell phone models. Our experimental results show that for all network topologies our algorithms were able to achieve "phase locking" between nodes even in the presence of hidden terminals. Moreover, we achieved battery lifetime extensions of as much as 28% for fully connected networks and about 20% for partially connected networks.
Chen, Wenxi; Kitazawa, Masumi; Togawa, Tatsuo
2009-09-01
This paper proposes a method to estimate a woman's menstrual cycle based on the hidden Markov model (HMM). A tiny device was developed that attaches around the abdominal region to measure cutaneous temperature at 10-min intervals during sleep. The measured temperature data were encoded as a two-dimensional image (QR code, i.e., quick response code) and displayed in the LCD window of the device. A mobile phone captured the QR code image, decoded the information and transmitted the data to a database server. The collected data were analyzed by three steps to estimate the biphasic temperature property in a menstrual cycle. The key step was an HMM-based step between preprocessing and postprocessing. A discrete Markov model, with two hidden phases, was assumed to represent higher- and lower-temperature phases during a menstrual cycle. The proposed method was verified by the data collected from 30 female participants, aged from 14 to 46, over six consecutive months. By comparing the estimated results with individual records from the participants, 71.6% of 190 menstrual cycles were correctly estimated. The sensitivity and positive predictability were 91.8 and 96.6%, respectively. This objective evaluation provides a promising approach for managing premenstrual syndrome and birth control.
Diffusion of the Digital Health Self-Tracking Movement in Canada: Results of a National Survey
Leaver, Chad; Bourget, Claire
2018-01-01
Background With the ever-increasing availability of mobile apps, consumer wearables, and smart medical devices, more and more individuals are self-tracking and managing their personal health data. Objective The aim of this study was to investigate the diffusion of the digital self-tracking movement in Canada. It provides a comprehensive, yet detailed account of this phenomenon. It examines the profile of digital self-trackers, traditional self-trackers, and nontrackers, further investigating the primary motivations for self-tracking and reasons for nontracking; barriers to adoption of connected care technologies; users’ appreciation of their self-tracking devices, including what they perceive to be the main benefits; factors that influence people’s intention to continue using connected care technologies in the future; and the reasons for usage discontinuance. Methods We conducted an online survey with a sample of 4109 Canadian adults, one of the largest ever. To ensure a representative sample, quota method was used (gender, age), following stratification by region. The maximum margin of error is estimated at 1.6%, 19 times out of 20. Results Our findings reveal that 66.20% (2720/4109) of our respondents regularly self-track one or more aspects of their health. About one in 4 respondents (1014/4109, 24.68%) currently owns a wearable or smart medical device, and 57.20% (580/1014) use their devices on a regular basis for self-tracking purposes. Digital self-trackers are typically young or mature adults, healthy, employed, university educated, with an annual family income of over $80,000 CAD. The most popular reported device is the fitness tracker or smartwatch that can capture a range of parameters. Currently, mobile apps and digital self-tracking devices are mainly used to monitor physical activity (856/1669, 51.13%), nutrition (545/1669, 32.65%), sleep patterns (482/1669, 28.88%) and, to a much lesser extent, cardiovascular and pulmonary biomarkers (215/1669, 12.88%), medication intake (126/1669, 7.55%), and glucose level (79/1669, 4.73%). Most users of connected care technologies (481/580, 83.0%) are highly satisfied and 88.2% (511/580) intend to continue using their apps and devices in the future. A majority said smart digital devices have allowed them to maintain or improve their health condition (398/580, 68.5%) and to be better informed about their health in general (387/580, 66.6%). About 33.80% of our sample (1389/4109) is composed of people who do not monitor their health or well-being on a regular basis. Conclusions Our study shows an opportunity to advance the health of Canadians through connected care technologies. Our findings can be used to set baseline information for future research on the rise of digital health self-tracking and its impacts. Although the use of mobile apps, consumer wearables, and smart medical devices could potentially benefit the growing population of patients with chronic conditions, the question remains as to whether it will diffuse broadly beyond early adopters and across cost inequities. PMID:29720359
Diffusion of the Digital Health Self-Tracking Movement in Canada: Results of a National Survey.
Paré, Guy; Leaver, Chad; Bourget, Claire
2018-05-02
With the ever-increasing availability of mobile apps, consumer wearables, and smart medical devices, more and more individuals are self-tracking and managing their personal health data. The aim of this study was to investigate the diffusion of the digital self-tracking movement in Canada. It provides a comprehensive, yet detailed account of this phenomenon. It examines the profile of digital self-trackers, traditional self-trackers, and nontrackers, further investigating the primary motivations for self-tracking and reasons for nontracking; barriers to adoption of connected care technologies; users' appreciation of their self-tracking devices, including what they perceive to be the main benefits; factors that influence people's intention to continue using connected care technologies in the future; and the reasons for usage discontinuance. We conducted an online survey with a sample of 4109 Canadian adults, one of the largest ever. To ensure a representative sample, quota method was used (gender, age), following stratification by region. The maximum margin of error is estimated at 1.6%, 19 times out of 20. Our findings reveal that 66.20% (2720/4109) of our respondents regularly self-track one or more aspects of their health. About one in 4 respondents (1014/4109, 24.68%) currently owns a wearable or smart medical device, and 57.20% (580/1014) use their devices on a regular basis for self-tracking purposes. Digital self-trackers are typically young or mature adults, healthy, employed, university educated, with an annual family income of over $80,000 CAD. The most popular reported device is the fitness tracker or smartwatch that can capture a range of parameters. Currently, mobile apps and digital self-tracking devices are mainly used to monitor physical activity (856/1669, 51.13%), nutrition (545/1669, 32.65%), sleep patterns (482/1669, 28.88%) and, to a much lesser extent, cardiovascular and pulmonary biomarkers (215/1669, 12.88%), medication intake (126/1669, 7.55%), and glucose level (79/1669, 4.73%). Most users of connected care technologies (481/580, 83.0%) are highly satisfied and 88.2% (511/580) intend to continue using their apps and devices in the future. A majority said smart digital devices have allowed them to maintain or improve their health condition (398/580, 68.5%) and to be better informed about their health in general (387/580, 66.6%). About 33.80% of our sample (1389/4109) is composed of people who do not monitor their health or well-being on a regular basis. Our study shows an opportunity to advance the health of Canadians through connected care technologies. Our findings can be used to set baseline information for future research on the rise of digital health self-tracking and its impacts. Although the use of mobile apps, consumer wearables, and smart medical devices could potentially benefit the growing population of patients with chronic conditions, the question remains as to whether it will diffuse broadly beyond early adopters and across cost inequities. ©Guy Paré, Chad Leaver, Claire Bourget. Originally published in the Journal of Medical Internet Research (http://www.jmir.org), 02.05.2018.
NASA Astrophysics Data System (ADS)
George, Paul; Kemeny, Andras; Colombet, Florent; Merienne, Frédéric; Chardonnet, Jean-Rémy; Thouvenin, Indira Mouttapa
2014-02-01
Immersive digital project reviews consist in using virtual reality (VR) as a tool for discussion between various stakeholders of a project. In the automotive industry, the digital car prototype model is the common thread that binds them. It is used during immersive digital project reviews between designers, engineers, ergonomists, etc. The digital mockup is also used to assess future car architecture, habitability or perceived quality requirements with the aim to reduce using physical mockups for optimized cost, delay and quality efficiency. Among the difficulties identified by the users, handling the mockup is a major one. Inspired by current uses of nomad devices (multi-touch gestures, IPhone UI look'n'feel and AR applications), we designed a navigation technique taking advantage of these popular input devices: Space scrolling allows moving around the mockup. In this paper, we present the results of a study we conducted on the usability and acceptability of the proposed smartphone-based interaction metaphor compared to traditional technique and we provide indications of the most efficient choices for different use-cases accordingly. It was carried out in a traditional 4-sided CAVE and its purpose is to assess a chosen set of interaction techniques to be implemented in Renault's new 5-sides 4K x 4K wall high performance CAVE. The proposed new metaphor using nomad devices is well accepted by novice VR users and future implementation should allow an efficient industrial use. Their use is an easy and user friendly alternative of the existing traditional control devices such as a joystick.
Patient agency revisited: "healing the hidden" in South India.
Sieler, Roman
2014-09-01
It is often argued that biomedicine alienates patients from doctors, from ailments and from understanding treatment processes, while indigenous and alternative healing systems are portrayed as respectful of patients and their experience. Specifically, South Indian siddha medicine has been seen as diverging from biomedicine in empowering its patients. This approach not only assumes biomedicine to be a homogeneous practice, but also lumps together diverse therapeutic techniques under the labels of "traditional" or "alternative." Analysis of a manual subdiscipline of siddha medicine cautions against such analytic imprecision and active/passive binaries in physician-patient encounters. Practitioners of vital spot medicine claim to "heal the hidden." They rarely communicate diagnostic insights verbally and object to auxiliary devices. However, their physical engagement with patients' ailing bodies highlights the corporeal nature of manual medicine in particular and processual, situational, and reciprocal characteristics of curing in general. © 2014 by the American Anthropological Association.
Noise-tolerant parity learning with one quantum bit
NASA Astrophysics Data System (ADS)
Park, Daniel K.; Rhee, June-Koo K.; Lee, Soonchil
2018-03-01
Demonstrating quantum advantage with less powerful but more realistic devices is of great importance in modern quantum information science. Recently, a significant quantum speedup was achieved in the problem of learning a hidden parity function with noise. However, if all data qubits at the query output are completely depolarized, the algorithm fails. In this work, we present a quantum parity learning algorithm that exhibits quantum advantage as long as one qubit is provided with nonzero polarization in each query. In this scenario, the quantum parity learning naturally becomes deterministic quantum computation with one qubit. Then the hidden parity function can be revealed by performing a set of operations that can be interpreted as measuring nonlocal observables on the auxiliary result qubit having nonzero polarization and each data qubit. We also discuss the source of the quantum advantage in our algorithm from the resource-theoretic point of view.
Is wave-particle objectivity compatible with determinism and locality?
Ionicioiu, Radu; Jennewein, Thomas; Mann, Robert B; Terno, Daniel R
2014-09-26
Wave-particle duality, superposition and entanglement are among the most counterintuitive features of quantum theory. Their clash with our classical expectations motivated hidden-variable (HV) theories. With the emergence of quantum technologies, we can test experimentally the predictions of quantum theory versus HV theories and put strong restrictions on their key assumptions. Here, we study an entanglement-assisted version of the quantum delayed-choice experiment and show that the extension of HV to the controlling devices only exacerbates the contradiction. We compare HV theories that satisfy the conditions of objectivity (a property of photons being either particles or waves, but not both), determinism and local independence of hidden variables with quantum mechanics. Any two of the above conditions are compatible with it. The conflict becomes manifest when all three conditions are imposed and persists for any non-zero value of entanglement. We propose an experiment to test our conclusions.
Is wave–particle objectivity compatible with determinism and locality?
Ionicioiu, Radu; Jennewein, Thomas; Mann, Robert B.; Terno, Daniel R.
2014-01-01
Wave–particle duality, superposition and entanglement are among the most counterintuitive features of quantum theory. Their clash with our classical expectations motivated hidden-variable (HV) theories. With the emergence of quantum technologies, we can test experimentally the predictions of quantum theory versus HV theories and put strong restrictions on their key assumptions. Here, we study an entanglement-assisted version of the quantum delayed-choice experiment and show that the extension of HV to the controlling devices only exacerbates the contradiction. We compare HV theories that satisfy the conditions of objectivity (a property of photons being either particles or waves, but not both), determinism and local independence of hidden variables with quantum mechanics. Any two of the above conditions are compatible with it. The conflict becomes manifest when all three conditions are imposed and persists for any non-zero value of entanglement. We propose an experiment to test our conclusions. PMID:25256419
Opportunity for All? Technology and Learning in Lower-Income Families
ERIC Educational Resources Information Center
Rideout, Victoria; Katz, Vikki S.
2016-01-01
Because digital devices and the Internet have become so essential, digital inequality can exacerbate educational and economic inequality as well. Therefore, it is critical to understand how low- and moderate-income families in the U.S. are engaging digital technologies and how they perceive the opportunities--and potential risks-- that these…
ERIC Educational Resources Information Center
Williamson, Ronald
2011-01-01
A "screenager" is a slang term used to describe teenagers who spend lots of time in front of digital screens (iPods, iPads, computers, other digital devices) (Webpodedia, 2011). The term is also used to describe the digital generation, students who are skilled at using technology to learn and communicate (Scherer, 2011). Given their comfort with…
Designing Computer-Based Learning Contents: Influence of Digital Zoom on Attention
ERIC Educational Resources Information Center
Glaser, Manuela; Lengyel, Dominik; Toulouse, Catherine; Schwan, Stephan
2017-01-01
In the present study, we investigated the role of digital zoom as a tool for directing attention while looking at visual learning material. In particular, we analyzed whether minimal digital zoom functions similarly to a rhetorical device by cueing mental zooming of attention accordingly. Participants were presented either static film clips, film…
Digital Leisure and Perceived Family Functioning in Youth of Upper Secondary Education
ERIC Educational Resources Information Center
Valdemoros-San-Emeterio, M-Angeles; Sanz-Arazuri, Eva; Ponce-de-León-Elizondo, Ana
2017-01-01
The "Network Society" is identified by accelerated changes that occur between real and virtual worlds. The progress of digital devices has generated a new model of leisure that has conditioned family interactions. The aim of this research was to identify the relationship between digital leisure experiences and perceived family…
Young Children's Learning with Digital Media
ERIC Educational Resources Information Center
Lieberman, Debra A.; Bates, Cynthia H.; So, Jiyeon
2009-01-01
This article reviews a selection of studies on digital media and learning for young children ages 3 to 6. The range of digital media for this age group is growing and includes computer-delivered and online activities; console video games; handheld media, occasionally with GPS or an accelerometer, in cell phones and other wireless mobile devices;…
ERIC Educational Resources Information Center
Henderson, Michael; Selwyn, Neil; Finger, Glenn; Aston, Rachel
2015-01-01
The much-discussed potential of "technology-enhanced learning" is not always apparent in the day-to-day use of digital technology throughout higher education. Against this background, the present paper considers the digital devices and resources that students engage most frequently with during their university studies, what these…
IoT-Forensics Meets Privacy: Towards Cooperative Digital Investigations
Lopez, Javier
2018-01-01
IoT-Forensics is a novel paradigm for the acquisition of electronic evidence whose operation is conditioned by the peculiarities of the Internet of Things (IoT) context. As a branch of computer forensics, this discipline respects the most basic forensic principles of preservation, traceability, documentation, and authorization. The digital witness approach also promotes such principles in the context of the IoT while allowing personal devices to cooperate in digital investigations by voluntarily providing electronic evidence to the authorities. However, this solution is highly dependent on the willingness of citizens to collaborate and they may be reluctant to do so if the sensitive information within their personal devices is not sufficiently protected when shared with the investigators. In this paper, we provide the digital witness approach with a methodology that enables citizens to share their data with some privacy guarantees. We apply the PRoFIT methodology, originally defined for IoT-Forensics environments, to the digital witness approach in order to unleash its full potential. Finally, we show the feasibility of a PRoFIT-compliant digital witness with two use cases. PMID:29414864
IoT-Forensics Meets Privacy: Towards Cooperative Digital Investigations.
Nieto, Ana; Rios, Ruben; Lopez, Javier
2018-02-07
IoT-Forensics is a novel paradigm for the acquisition of electronic evidence whose operation is conditioned by the peculiarities of the Internet of Things (IoT) context. As a branch of computer forensics, this discipline respects the most basic forensic principles of preservation, traceability, documentation, and authorization. The digital witness approach also promotes such principles in the context of the IoT while allowing personal devices to cooperate in digital investigations by voluntarily providing electronic evidence to the authorities. However, this solution is highly dependent on the willingness of citizens to collaborate and they may be reluctant to do so if the sensitive information within their personal devices is not sufficiently protected when shared with the investigators. In this paper, we provide the digital witness approach with a methodology that enables citizens to share their data with some privacy guarantees. We apply the PRoFIT methodology, originally defined for IoT-Forensics environments, to the digital witness approach in order to unleash its full potential. Finally, we show the feasibility of a PRoFIT-compliant digital witness with two use cases.
Silicon photonics devices for metro applications
NASA Astrophysics Data System (ADS)
Fukuda, H.; Kikuchi, K.; Jizodo, M.; Kawamura, Y.; Takeda, K.; Honda, K.
2017-01-01
Digital coherent technology is considered an attractive way of realizing both high-speed metro links and long distance transmissions. In metro areas, there is a strong demand for a smaller, faster transceiver module. This demand is mainly driven by the rapidly increasing data center interconnection traffic, where transmission capacity per faceplane is a key feature. Therefore, optical integration technology is desired. Since compensation in digital coherent technology is performed in the electrical or digital domain, users can deal with those optics performances that are not compensated for digitally. This means using a new material that cannot provide perfect characteristics but that is suitable for miniaturization and integration is possible. Silicon photonics (SiPh) is considered an attractive technology that would enable the significant miniaturization of optical circuits and be capable of optical integration with high manufacturability. While SiPh-based devices have begun to be deployed for very short or short reach links on the basis of direct detection technology, their digital coherent applications have recently been investigated in view of their integration capability. This paper describes recent progress on SiPh-based integrated optical devices for high-speed digital coherent transceivers targeting metro links. An optical modulator and receiver with related circuits have been integrated into a single SiPh chip. TEC-free operation under non-hermetic conditions and the direct attachment of optical fibers have both been realized. Very thin and small packaging with sufficient performance has been demonstrated by using the SiPh chip co-packaged with high-speed ICs.
Digital Data Matrix Scanner Developnent At Marshall Space Flight Center
NASA Technical Reports Server (NTRS)
2004-01-01
Research at NASA's Marshall Space Flight Center has resulted in a system for reading hidden identification codes using a hand-held magnetic scanner. It's an invention that could help businesses improve inventory management, enhance safety, improve security, and aid in recall efforts if defects are discovered. Two-dimensional Data Matrix symbols consisting of letters and numbers permanently etched on items for identification and resembling a small checkerboard pattern are more efficient and reliable than traditional bar codes, and can store up to 100 times more information. A team led by Fred Schramm of the Marshall Center's Technology Transfer Department, in partnership with PRI,Torrance, California, has developed a hand-held device that can read this special type of coded symbols, even if covered by up to six layers of paint. Before this new technology was available, matrix symbols were read with optical scanners, and only if the codes were visible. This latest improvement in digital Data Matrix technologies offers greater flexibility for businesses and industries already using the marking system. Paint, inks, and pastes containing magnetic properties are applied in matrix symbol patterns to objects with two-dimensional codes, and the codes are read by a magnetic scanner, even after being covered with paint or other coatings. The ability to read hidden matrix symbols promises a wide range of benefits in a number of fields, including airlines, electronics, healthcare, and the automotive industry. Many industries would like to hide information on a part, so it can be read only by the party who put it there. For instance, the automotive industry uses direct parts marking for inventory control, but for aesthetic purposes the marks often need to be invisible. Symbols have been applied to a variety of materials, including metal, plastic, glass, paper, fabric and foam, on everything from electronic parts to pharmaceuticals to livestock. The portability of the hand-held scanner makes work faster and easier. It reads marks in darkness, under bright light that might interfere with optical reading of visible marks, and can detect symbols obscured by discoloration or contamination. Through a license with NASA, another partner, Robotic Vision Systems, Inc., of Nashua, New Hampshire, will sell the scanner on the commercial market. NASA continues to seek additional companies to license the product. Joint efforts by Marshall researchers and industry partners are aimed at improving dentification technology as part of NASA's program to better life on Earth through technology designed for the space program. In this photo, Don Roxby, Robotic Vision Systems, Inc., (left)demonstrates the magnetic handheld scanner for Fred Schramm, (Right) MSFC Technology Transfer Department.
Mehl, Albert; Bosch, Gabriel; Fischer, Carolin; Ender, Andreas
Three-dimensional (3D) intraoral scanning systems allow for the simultaneous acquisition of 3D information about tooth surfaces and a photorealistic view of the patient's tooth colors. The goal of this study was the in vivo comparison of a new 3D scanner with a color acquisition mode and conventional visual and digital color measurements. The colors of 40 teeth of 20 patients were evaluated in seven ways: 1) By dentists using the Vita 3D-Master; 2) By dental technicians using the Vita 3D-Master; 3) With the 3Shape Trios device; 4) With the Vita Easyshade device; 5) With the Vita Easyshade Advance device; 6) With the SpectroShade device; and 7) With the SpectroShade Micro device. Digital measurements of Groups 3 to 7 were repeated three times for each tooth. For all groups, both the CIE Lab values and the Vita 3D-Master values were recorded. The repeatability and relative accuracy of the Vita 3D-Master values were analyzed statistically using Pearson's chi-squared test (α < 0.05). ΔE values were calculated from the CIE Lab values, which served as a basis for performing multidimensional scaling (MDS) and evaluating differences between the groups using the one-way ANOVA with post hoc Tamhane's test (α < 0.05). The results of the ΔE values showed that clinically relevant differences between the evaluation by dentists, dental technicians, and the intraoral scanning device (3Shape) are negligible. The intraoral 3D scanning device (Group 3) and the digital systems (Groups 4 to 7) did not differ significantly in the repeatability of color shade management. The SpectroShade Micro (Group 7) had significantly better relative accuracy than the other devices. The results demonstrate that intraoral scanning systems can be used to measure both tooth color and tooth surface in 3D. Intraoral optical scanning devices allow for the acquisition of accurate 3D surface data. Tooth color can be evaluated simultaneously and can be used to determine the color of restorations without requiring additional conventional color-measurement methods.
The Fundamentals of Using the Digital Micromirror Device (DMD(TM)) for Projection Display
NASA Technical Reports Server (NTRS)
Yoder, Lars A.
1995-01-01
Developed by Texas Instruments (TI) the digital micromirror device (DMD(tm)) is a quickly emerging and highly useful micro-electro-mechanical structures (MEMS) device. Using standard semiconductor fabrication technology, the DMD's simplicity in concept and design will provide advantageous solutions for many different applications. At the rudimentary level, the DMD is a precision, semiconductor light switch. In the initial commercial development of DMD technology, TI has concentrated on projection display and hardcopy. This paper will focus on how the DMD is used for projection display. Other application areas are being explored and evaluated to find appropriate and beneficial uses for the DMD.
Design and Development of Intelligent Electrodes for Future Digital Health Monitoring: A Review
NASA Astrophysics Data System (ADS)
Khairuddin, A. M.; Azir, K. N. F. Ku; Kan, P. Eh
2018-03-01
Electrodes are sensors used in electrocardiography (ECG) monitoring system to diagnose heart diseases. Over the years, diverse types of electrodes have been designed and developed to improve ECG monitoring system. However, more recently, with the technological advances and capabilities from the Internet of Things (IoT), cloud computing and data analytics in personalized healthcare, researchers are attempting to design and develop more effective as well as flexible ECG devices by using intelligent electrodes. This paper reviews previous works on electrodes used in electrocardiography (ECG) monitoring devices to identify the key ftures for designing and developing intelligent electrodes in digital health monitoring devices.
Digital micromirror device as amplitude diffuser for multiple-plane phase retrieval
NASA Astrophysics Data System (ADS)
Abregana, Timothy Joseph T.; Hermosa, Nathaniel P.; Almoro, Percival F.
2017-06-01
Previous implementations of the phase diffuser used in the multiple-plane phase retrieval method included a diffuser glass plate with fixed optical properties or a programmable yet expensive spatial light modulator. Here a model for phase retrieval based on a digital micromirror device as amplitude diffuser is presented. The technique offers programmable, convenient and low-cost amplitude diffuser for a non-stagnating iterative phase retrieval. The technique is demonstrated in the reconstructions of smooth object wavefronts.
O'Connor, Timothy; Rawat, Siddharth; Markman, Adam; Javidi, Bahram
2018-03-01
We propose a compact imaging system that integrates an augmented reality head mounted device with digital holographic microscopy for automated cell identification and visualization. A shearing interferometer is used to produce holograms of biological cells, which are recorded using customized smart glasses containing an external camera. After image acquisition, segmentation is performed to isolate regions of interest containing biological cells in the field-of-view, followed by digital reconstruction of the cells, which is used to generate a three-dimensional (3D) pseudocolor optical path length profile. Morphological features are extracted from the cell's optical path length map, including mean optical path length, coefficient of variation, optical volume, projected area, projected area to optical volume ratio, cell skewness, and cell kurtosis. Classification is performed using the random forest classifier, support vector machines, and K-nearest neighbor, and the results are compared. Finally, the augmented reality device displays the cell's pseudocolor 3D rendering of its optical path length profile, extracted features, and the identified cell's type or class. The proposed system could allow a healthcare worker to quickly visualize cells using augmented reality smart glasses and extract the relevant information for rapid diagnosis. To the best of our knowledge, this is the first report on the integration of digital holographic microscopy with augmented reality devices for automated cell identification and visualization.
Kim, Tae-Hoon; Heo, Dong-Woon; Jeong, Chang-Won; Ryu, Jong-Hyun; Jun, Hong Young; Han, Seung-Jun; Ha, Taeuk; Yoon, Kwon-Ha
2017-01-01
This study developed a device measuring the X-ray source-detector angle (SDA) and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR) was evaluated using the signal-to-noise (SNR), contrast-to-noise ratio (CNR), spatial resolution, distortion and entrance surface dose (ESD). According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm) and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles (p < 0.05), whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines. PMID:28272336
Kim, Tae-Hoon; Heo, Dong-Woon; Jeong, Chang-Won; Ryu, Jong-Hyun; Jun, Hong Young; Han, Seung-Jun; Ha, Taeuk; Yoon, Kwon-Ha
2017-03-07
This study developed a device measuring the X-ray source-detector angle (SDA) and evaluated the imaging performance for diagnosing chest images. The SDA device consisted of Arduino, an accelerometer and gyro sensor, and a Bluetooth module. The SDA values were compared with the values of a digital angle meter. The performance of the portable digital radiography (PDR) was evaluated using the signal-to-noise (SNR), contrast-to-noise ratio (CNR), spatial resolution, distortion and entrance surface dose (ESD). According to different angle degrees, five anatomical landmarks were assessed using a five-point scale. The mean SNR and CNR were 182.47 and 141.43. The spatial resolution and ESD were 3.17 lp/mm (157 μm) and 0.266 mGy. The angle values of the SDA device were not significantly difference as compared to those of the digital angle meter. In chest imaging, the SNR and CNR values were not significantly different according to the different angle degrees. The visibility scores of the border of the heart, the fifth rib and the scapula showed significant differences according to different angles ( p < 0.05), whereas the scores of the clavicle and first rib were not significant. It is noticeable that the increase in the SDA degree was consistent with the increases of the distortion and visibility score. The proposed PDR with a SDA device would be useful for application in the clinical radiography setting according to the standard radiography guidelines.
Shih, Chih-Jen; Wang, Qing Hua; Son, Youngwoo; Jin, Zhong; Blankschtein, Daniel; Strano, Michael S
2014-06-24
Field-effect transistor (FET) devices composed of a MoS2-graphene heterostructure can combine the advantages of high carrier mobility in graphene with the permanent band gap of MoS2 for digital applications. Herein, we investigate the electron transfer, photoluminescence, and gate-controlled carrier transport in such a heterostructure. We show that the junction is a Schottky barrier, whose height can be artificially controlled by gating or doping graphene. When the applied gate voltage (or the doping level) is zero, the photoexcited electron-hole pairs in monolayer MoS2 can be split by the heterojunction, significantly reducing the photoluminescence. By applying negative gate voltage (or p-doping) in graphene, the interlayer impedance formed between MoS2 and graphene exhibits an 100-fold increase. For the first time, we show that the gate-controlled interlayer Schottky impedance can be utilized to modulate carrier transport in graphene, significantly depleting the hole transport, but preserving the electron transport. Accordingly, we demonstrate a new type of FET device, which enables a controllable transition from NMOS digital to bipolar characteristics. In the NMOS digital regime, we report a very high room temperature on/off current ratio (ION/IOFF ∼ 36) in comparison to graphene-based FET devices without sacrificing the field-effect electron mobilities in graphene. By engineering the source/drain contact area, we further estimate that a higher value of ION/IOFF up to 100 can be obtained in the device architecture considered. The device architecture presented here may enable semiconducting behavior in graphene for digital and analogue electronics.
High-performance computing for airborne applications
DOE Office of Scientific and Technical Information (OSTI.GOV)
Quinn, Heather M; Manuzzato, Andrea; Fairbanks, Tom
2010-06-28
Recently, there has been attempts to move common satellite tasks to unmanned aerial vehicles (UAVs). UAVs are significantly cheaper to buy than satellites and easier to deploy on an as-needed basis. The more benign radiation environment also allows for an aggressive adoption of state-of-the-art commercial computational devices, which increases the amount of data that can be collected. There are a number of commercial computing devices currently available that are well-suited to high-performance computing. These devices range from specialized computational devices, such as field-programmable gate arrays (FPGAs) and digital signal processors (DSPs), to traditional computing platforms, such as microprocessors. Even thoughmore » the radiation environment is relatively benign, these devices could be susceptible to single-event effects. In this paper, we will present radiation data for high-performance computing devices in a accelerated neutron environment. These devices include a multi-core digital signal processor, two field-programmable gate arrays, and a microprocessor. From these results, we found that all of these devices are suitable for many airplane environments without reliability problems.« less
Choudhri, Asim F; Radvany, Martin G
2011-04-01
Medical imaging is commonly used to diagnose many emergent conditions, as well as plan treatment. Digital images can be reviewed on almost any computing platform. Modern mobile phones and handheld devices are portable computing platforms with robust software programming interfaces, powerful processors, and high-resolution displays. OsiriX mobile, a new Digital Imaging and Communications in Medicine viewing program, is available for the iPhone/iPod touch platform. This raises the possibility of mobile review of diagnostic medical images to expedite diagnosis and treatment planning using a commercial off the shelf solution, facilitating communication among radiologists and referring clinicians.
Application and Design Characteristics of Generalized Training Devices.
ERIC Educational Resources Information Center
Parker, Edward L.
This program identified applications and developed design characteristics for generalized training devices. The first of three sequential phases reviewed in detail new developments in Naval equipment technology that influence the design of maintenance training devices: solid-state circuitry, modularization, digital technology, standardization,…
Compendium of Current Total Ionizing Dose and Displacement Damage Results from NASA GSFC and NEPP
NASA Technical Reports Server (NTRS)
Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Label, Kenneth A.; Cochran, Donna J.; O'Bryan, Martha V.
2017-01-01
Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include opto-electronics, digital, analog, linear bipolar devices, and hybrid devices.
47 CFR 15.309 - Cross reference.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Telecommunication FEDERAL COMMUNICATIONS COMMISSION GENERAL RADIO FREQUENCY DEVICES Unlicensed Personal Communications Service Devices § 15.309 Cross reference. (a) The provisions of subpart A of this part apply to... PCS device that includes digital circuitry not directly associated with the radio transmitter also is...
Federal Register 2010, 2011, 2012, 2013, 2014
2017-08-02
... following respondents: SanDisk LLC of Milpitas, California; Western Digital Corporation of Irvine, California; Western Digital Technologies, Inc. of Milpitas, California; SanDisk Limited of Yokohama, Japan...
Invisible waves and hidden realms: augmented reality and experimental art
NASA Astrophysics Data System (ADS)
Ruzanka, Silvia
2012-03-01
Augmented reality is way of both altering the visible and revealing the invisible. It offers new opportunities for artistic exploration through virtual interventions in real space. In this paper, the author describes the implementation of two art installations using different AR technologies, one using optical marker tracking on mobile devices and one integrating stereoscopic projections into the physical environment. The first artwork, De Ondas y Abejas (The Waves and the Bees), is based on the widely publicized (but unproven) hypothesis of a link between cellphone radiation and the phenomenon of bee colony collapse disorder. Using an Android tablet, viewers search out small fiducial markers in the shape of electromagnetic waves hidden throughout the gallery, which reveal swarms of bees scattered on the floor. The piece also creates a generative soundscape based on electromagnetic fields. The second artwork, Urban Fauna, is a series of animations in which features of the urban landscape become plants and animals. Surveillance cameras become flocks of birds while miniature cellphone towers, lampposts, and telephone poles grow like small seedlings in time-lapse animation. The animations are presented as small stereoscopic projections, integrated into the physical space of the gallery. These two pieces explore the relationship between nature and technology through the visualization of invisible forces and hidden alternate realities.
Hidden Gratings in Holographic Liquid Crystal Polymer-Dispersed Liquid Crystal Films.
De Sio, Luciano; Lloyd, Pamela F; Tabiryan, Nelson V; Bunning, Timothy J
2018-04-18
Dynamic diffraction gratings that are hidden in the field-off state are fabricated utilizing a room-temperature photocurable liquid crystal (LC) monomer and nematic LC (NLC) using holographic photopolymerization techniques. These holographic LC polymer-dispersed LCs (HLCPDLCs) are hidden because of the refractive index matching between the LC polymer and the NLC regions in the as-formed state (no E-field applied). Application of a moderate E-field (5 V/μm) generates a refractive index mismatch because of the NLC reorientation (along the E-field) generating high-diffraction efficiency transmission gratings. These dynamic gratings are characterized by morphological, optical, and electrooptical techniques. They exhibit a morphology made of oriented LC polymer regions (containing residual NLC) alternating with a two-phase region of an NLC and LC polymer. Unlike classic holographic polymer-dispersed LC gratings formed with a nonmesogenic monomer, there is index matching between the as-formed alternating regions of the grating. These HLCPDLCs exhibit broad band and high diffraction efficiency (≈90%) at the Bragg angle, are transparent to white light across the visible range because of the refractive index matching, and exhibit fast response times (1 ms). The ability of HLCPDLCs not to consume electrical power in the off state opens new possibilities for the realization of energy-efficient switchable photonic devices.
Kretzschmar, Franziska; Pleimling, Dominique; Hosemann, Jana; Füssel, Stephan; Bornkessel-Schlesewsky, Ina; Schlesewsky, Matthias
2013-01-01
In the rapidly changing circumstances of our increasingly digital world, reading is also becoming an increasingly digital experience: electronic books (e-books) are now outselling print books in the United States and the United Kingdom. Nevertheless, many readers still view e-books as less readable than print books. The present study thus used combined EEG and eyetracking measures in order to test whether reading from digital media requires higher cognitive effort than reading conventional books. Young and elderly adults read short texts on three different reading devices: a paper page, an e-reader and a tablet computer and answered comprehension questions about them while their eye movements and EEG were recorded. The results of a debriefing questionnaire replicated previous findings in that participants overwhelmingly chose the paper page over the two electronic devices as their preferred reading medium. Online measures, by contrast, showed shorter mean fixation durations and lower EEG theta band voltage density--known to covary with memory encoding and retrieval--for the older adults when reading from a tablet computer in comparison to the other two devices. Young adults showed comparable fixation durations and theta activity for all three devices. Comprehension accuracy did not differ across the three media for either group. We argue that these results can be explained in terms of the better text discriminability (higher contrast) produced by the backlit display of the tablet computer. Contrast sensitivity decreases with age and degraded contrast conditions lead to longer reading times, thus supporting the conclusion that older readers may benefit particularly from the enhanced contrast of the tablet. Our findings thus indicate that people's subjective evaluation of digital reading media must be dissociated from the cognitive and neural effort expended in online information processing while reading from such devices.
Kretzschmar, Franziska; Pleimling, Dominique; Hosemann, Jana; Füssel, Stephan; Bornkessel-Schlesewsky, Ina; Schlesewsky, Matthias
2013-01-01
In the rapidly changing circumstances of our increasingly digital world, reading is also becoming an increasingly digital experience: electronic books (e-books) are now outselling print books in the United States and the United Kingdom. Nevertheless, many readers still view e-books as less readable than print books. The present study thus used combined EEG and eyetracking measures in order to test whether reading from digital media requires higher cognitive effort than reading conventional books. Young and elderly adults read short texts on three different reading devices: a paper page, an e-reader and a tablet computer and answered comprehension questions about them while their eye movements and EEG were recorded. The results of a debriefing questionnaire replicated previous findings in that participants overwhelmingly chose the paper page over the two electronic devices as their preferred reading medium. Online measures, by contrast, showed shorter mean fixation durations and lower EEG theta band voltage density – known to covary with memory encoding and retrieval – for the older adults when reading from a tablet computer in comparison to the other two devices. Young adults showed comparable fixation durations and theta activity for all three devices. Comprehension accuracy did not differ across the three media for either group. We argue that these results can be explained in terms of the better text discriminability (higher contrast) produced by the backlit display of the tablet computer. Contrast sensitivity decreases with age and degraded contrast conditions lead to longer reading times, thus supporting the conclusion that older readers may benefit particularly from the enhanced contrast of the tablet. Our findings thus indicate that people's subjective evaluation of digital reading media must be dissociated from the cognitive and neural effort expended in online information processing while reading from such devices. PMID:23405265
Real-time volume rendering of digital medical images on an iOS device
NASA Astrophysics Data System (ADS)
Noon, Christian; Holub, Joseph; Winer, Eliot
2013-03-01
Performing high quality 3D visualizations on mobile devices, while tantalizingly close in many areas, is still a quite difficult task. This is especially true for 3D volume rendering of digital medical images. Allowing this would empower medical personnel a powerful tool to diagnose and treat patients and train the next generation of physicians. This research focuses on performing real time volume rendering of digital medical images on iOS devices using custom developed GPU shaders for orthogonal texture slicing. An interactive volume renderer was designed and developed with several new features including dynamic modification of render resolutions, an incremental render loop, a shader-based clipping algorithm to support OpenGL ES 2.0, and an internal backface culling algorithm for properly sorting rendered geometry with alpha blending. The application was developed using several application programming interfaces (APIs) such as OpenSceneGraph (OSG) as the primary graphics renderer coupled with iOS Cocoa Touch for user interaction, and DCMTK for DICOM I/O. The developed application rendered volume datasets over 450 slices up to 50-60 frames per second, depending on the specific model of the iOS device. All rendering is done locally on the device so no Internet connection is required.
Harrefors, Christina; Sävenstedt, Stefan; Lundquist, Anders; Lundquist, Bengt; Axelsson, Karin
2012-01-01
Cognitive impairments influence the possibility of persons with dementia to remember daily events and maintain a sense of self. In order to address these problems a digital photo diary was developed to capture information about events in daily life. The device consisted of a wearable digital camera, smart phone with Global Positioning System (GPS) and a home memory station with computer for uploading the photographs and touch screen. The aim of this study was to describe professional caregiver’s perceptions on how persons with mild dementia might experience the usage of this digital photo diary from both a situation when wearing the camera and a situation when viewing the uploaded photos, through a questionnaire with 408 respondents. In order to catch the professional caregivers’ perceptions a questionnaire with the semantic differential technique was used and the main question was “How do you think Hilda (the fictive person in the questionnaire) feels when she is using the digital photo diary?”. The factor analysis revealed three factors; Sense of autonomy, Sense of self-esteem and Sense of trust. An interesting conclusion that can be drawn is that professional caregivers had an overall positive view of the usage of digital photo diary as supporting autonomy for persons with mild dementia. The meaningfulness of each situation when wearing the camera and viewing the uploaded pictures to be used in two different situations and a part of an integrated assistive device has to be considered separately. Individual needs and desires of the person who is living with dementia and the context of each individual has to be reflected on and taken into account before implementing assistive digital devices as a tool in care. PMID:22509232
Development and pilot testing of HEXORR: Hand EXOskeleton Rehabilitation Robot
2010-01-01
Background Following acute therapeutic interventions, the majority of stroke survivors are left with a poorly functioning hemiparetic hand. Rehabilitation robotics has shown promise in providing patients with intensive therapy leading to functional gains. Because of the hand's crucial role in performing activities of daily living, attention to hand therapy has recently increased. Methods This paper introduces a newly developed Hand Exoskeleton Rehabilitation Robot (HEXORR). This device has been designed to provide full range of motion (ROM) for all of the hand's digits. The thumb actuator allows for variable thumb plane of motion to incorporate different degrees of extension/flexion and abduction/adduction. Compensation algorithms have been developed to improve the exoskeleton's backdrivability by counteracting gravity, stiction and kinetic friction. We have also designed a force assistance mode that provides extension assistance based on each individual's needs. A pilot study was conducted on 9 unimpaired and 5 chronic stroke subjects to investigate the device's ability to allow physiologically accurate hand movements throughout the full ROM. The study also tested the efficacy of the force assistance mode with the goal of increasing stroke subjects' active ROM while still requiring active extension torque on the part of the subject. Results For 12 of the hand digits'15 joints in neurologically normal subjects, there were no significant ROM differences (P > 0.05) between active movements performed inside and outside of HEXORR. Interjoint coordination was examined in the 1st and 3rd digits, and no differences were found between inside and outside of the device (P > 0.05). Stroke subjects were capable of performing free hand movements inside of the exoskeleton and the force assistance mode was successful in increasing active ROM by 43 ± 5% (P < 0.001) and 24 ± 6% (P = 0.041) for the fingers and thumb, respectively. Conclusions Our pilot study shows that this device is capable of moving the hand's digits through nearly the entire ROM with physiologically accurate trajectories. Stroke subjects received the device intervention well and device impedance was minimized so that subjects could freely extend and flex their digits inside of HEXORR. Our active force-assisted condition was successful in increasing the subjects' ROM while promoting active participation. PMID:20667083
Analysis and design of digital output interface devices for gas turbine electronic controls
NASA Technical Reports Server (NTRS)
Newirth, D. M.; Koenig, E. W.
1976-01-01
A trade study was performed on twenty-one digital output interface schemes for gas turbine electronic controls to select the most promising scheme based on criteria of reliability, performance, cost, and sampling requirements. The most promising scheme, a digital effector with optical feedback of the fuel metering valve position, was designed.
Applying Digital Sensor Technology: A Problem-Solving Approach
ERIC Educational Resources Information Center
Seedhouse, Paul; Knight, Dawn
2016-01-01
There is currently an explosion in the number and range of new devices coming onto the technology market that use digital sensor technology to track aspects of human behaviour. In this article, we present and exemplify a three-stage model for the application of digital sensor technology in applied linguistics that we have developed, namely,…
ERIC Educational Resources Information Center
Leow, Fui-Theng; Neo, Mai; Hew, Soon Hin
2016-01-01
The 21st century marks the beginning of digital age with the extensive use of digital media, mobile devices, and Internet resources. Recent studies found that this digital era has expanded the landscape of student experiences, and educational technologies as well as increased the educator's awareness on embracing technologies to promote effective…
How Digital Technologies, Blended Learning and MOOCs Will Impact the Future of Higher Education
ERIC Educational Resources Information Center
Morris, Neil P.
2014-01-01
Digital technologies are revolutionizing all parts of society, including higher education. Universities are rapidly adapting to the prevalence of staff and student mobile devices, digital tools and services on campus, and are developing strategies to harness these technologies to enhance student learning. In this paper, I explore the use of…
NASA Astrophysics Data System (ADS)
Opanchuk, B.; Arnaud, L.; Reid, M. D.
2014-06-01
We demonstrate the principle of one-sided device-independent continuous-variable (CV) quantum information. In situations of no trust, we show by enactment how the use of standard CV entanglement criteria can mislead Charlie into thinking that Alice and Bob share entanglement, when the data are actually generated classically using a local-hidden-variable theory based on the Wigner function. We distinguish between criteria that demonstrate CV entanglement, and criteria that demonstrate the CV Einstein-Podolsky-Rosen (EPR) steering paradox. We show that the latter, but not the former, are necessarily one-sided device-independent entanglement witnesses, and can be used by Charlie to signify genuine EPR entanglement, if he trusts only Alice. A monogamy result for the EPR steering paradox confirms the security of the shared amplitude values in that case.
Probabilistic Multi-Sensor Fusion Based Indoor Positioning System on a Mobile Device
He, Xiang; Aloi, Daniel N.; Li, Jia
2015-01-01
Nowadays, smart mobile devices include more and more sensors on board, such as motion sensors (accelerometer, gyroscope, magnetometer), wireless signal strength indicators (WiFi, Bluetooth, Zigbee), and visual sensors (LiDAR, camera). People have developed various indoor positioning techniques based on these sensors. In this paper, the probabilistic fusion of multiple sensors is investigated in a hidden Markov model (HMM) framework for mobile-device user-positioning. We propose a graph structure to store the model constructed by multiple sensors during the offline training phase, and a multimodal particle filter to seamlessly fuse the information during the online tracking phase. Based on our algorithm, we develop an indoor positioning system on the iOS platform. The experiments carried out in a typical indoor environment have shown promising results for our proposed algorithm and system design. PMID:26694387
Probabilistic Multi-Sensor Fusion Based Indoor Positioning System on a Mobile Device.
He, Xiang; Aloi, Daniel N; Li, Jia
2015-12-14
Nowadays, smart mobile devices include more and more sensors on board, such as motion sensors (accelerometer, gyroscope, magnetometer), wireless signal strength indicators (WiFi, Bluetooth, Zigbee), and visual sensors (LiDAR, camera). People have developed various indoor positioning techniques based on these sensors. In this paper, the probabilistic fusion of multiple sensors is investigated in a hidden Markov model (HMM) framework for mobile-device user-positioning. We propose a graph structure to store the model constructed by multiple sensors during the offline training phase, and a multimodal particle filter to seamlessly fuse the information during the online tracking phase. Based on our algorithm, we develop an indoor positioning system on the iOS platform. The experiments carried out in a typical indoor environment have shown promising results for our proposed algorithm and system design.
[Management of hearing impairment in adults].
Frachet, Bruno; Poncet-Wallet, Christine; Ernst, Imilie; Quéruel, Françoise; Eshraghi, Adrien
2009-10-20
Hearing impairment, mainly the deafness with possible distortions, assorted with tinnitus concerns about 4 million of the French population. It can be of variable severity. Deafness is an invisible disability until we must answer a question. The permanent improvement of the computer and microelectronics sciences benefit to the prosthetic devices: cochlear implants compensate for complete hearing loss, hearing aids are hidden by being miniaturized, being partially or totally implantable. The management of disability is not limited to this material part: human assistance and assistive devices are part of the armory. Rest to continue and to increase the financial support. This claim is obviously not specific to disability hearing although the hearing aid is only refunded 138 Euro per device for a unit cost from 1300 Euro to 2500 Euro with an observed lifetime of 4 or 5 years.
Development of High Resolution Eddy Current Imaging Using an Electro-Mechanical Sensor (Preprint)
2011-11-01
The Fluxgate Magnetometer ,” J. Phys. E: Sci. Instrum., Vol. 12: 241-253. 13. A. Abedi, J. J. Fellenstein, A. J. Lucas, and J. P. Wikswo, Jr., “A...206 (2006). 11. Ripka, P., 1992, Review of Fluxgate Sensors, Sensors and Actuators, A. 33, Elsevier Sequoia: 129-141. 12. Primdahl, F., 1979...superconducting quantum interference device magnetometer system for quantitative analysis and imaging of hidden corrosion activity in aircraft aluminum
Digital dental surface registration with laser scanner for orthodontics set-up planning
NASA Astrophysics Data System (ADS)
Alcaniz-Raya, Mariano L.; Albalat, Salvador E.; Grau Colomer, Vincente; Monserrat, Carlos A.
1997-05-01
We present an optical measuring system based on laser structured light suitable for its diary use in orthodontics clinics that fit four main requirements: (1) to avoid use of stone models, (2) to automatically discriminate geometric points belonging to teeth and gum, (3) to automatically calculate diagnostic parameters used by orthodontists, (4) to make use of low cost and easy to use technology for future commercial use. Proposed technique is based in the use of hydrocolloids mould used by orthodontists for stone model obtention. These mould of the inside of patient's mouth are composed of very fluent materials like alginate or hydrocolloids that reveal fine details of dental anatomy. Alginate mould are both very easy to obtain and very low costly. Once captured, alginate moulds are digitized by mean of a newly developed and patented 3D dental scanner. Developed scanner is based in the optical triangulation method based in the projection of a laser line on the alginate mould surface. Line deformation gives uncalibrated shape information. Relative linear movements of the mould with respect to the sensor head gives more sections thus obtaining a full 3D uncalibrated dentition model. Developed device makes use of redundant CCD in the sensor head and servocontrolled linear axis for mould movement. Last step is calibration to get a real and precise X, Y, Z image. All the process is done automatically. The scanner has been specially adapted for 3D dental anatomy capturing in order to fulfill specific requirements such as: scanning time, accuracy, security and correct acquisition of 'hidden points' in alginate mould. Measurement realized on phantoms with known geometry quite similar to dental anatomy present errors less than 0,1 mm. Scanning of global dental anatomy is 2 minutes, and generation of 3D graphics of dental cast takes approximately 30 seconds in a Pentium-based PC.
Current State of the Regulatory Trajectory for Whole Slide Imaging Devices in the USA
Abels, Esther; Pantanowitz, Liron
2017-01-01
The regulatory field for digital pathology (DP) has advanced significantly. A major milestone was accomplished when the FDA allowed the first vendor to market their device for primary diagnostic use in the USA and published in the classification order that this device, and substantially equivalent devices of this generic type, should be classified into class II instead of class III as previously proposed. The Digital Pathology Association (DPA) regulatory task force had a major role in the accomplishment of getting the application request for Whole Slide Imaging (WSI) Systems recommended for a de novo. This article reviews the past and emerging regulatory environment of WSI for clinical use in the USA. A WSI system with integrated subsystems is defined in the context of medical device regulations. The FDA technical performance assessment guideline is also discussed as well as parameters involved in analytical testing and clinical studies to demonstrate that WSI devices are safe and effective for clinical use. PMID:28584684
Current State of the Regulatory Trajectory for Whole Slide Imaging Devices in the USA.
Abels, Esther; Pantanowitz, Liron
2017-01-01
The regulatory field for digital pathology (DP) has advanced significantly. A major milestone was accomplished when the FDA allowed the first vendor to market their device for primary diagnostic use in the USA and published in the classification order that this device, and substantially equivalent devices of this generic type, should be classified into class II instead of class III as previously proposed. The Digital Pathology Association (DPA) regulatory task force had a major role in the accomplishment of getting the application request for Whole Slide Imaging (WSI) Systems recommended for a de novo . This article reviews the past and emerging regulatory environment of WSI for clinical use in the USA. A WSI system with integrated subsystems is defined in the context of medical device regulations. The FDA technical performance assessment guideline is also discussed as well as parameters involved in analytical testing and clinical studies to demonstrate that WSI devices are safe and effective for clinical use.
Edge enhancement of color images using a digital micromirror device.
Di Martino, J Matías; Flores, Jorge L; Ayubi, Gastón A; Alonso, Julia R; Fernández, Ariel; Ferrari, José A
2012-06-01
A method for orientation-selective enhancement of edges in color images is proposed. The method utilizes the capacity of digital micromirror devices to generate a positive and a negative color replica of the image used as input. When both images are slightly displaced and imagined together, one obtains an image with enhanced edges. The proposed technique does not require a coherent light source or precise alignment. The proposed method could be potentially useful for processing large image sequences in real time. Validation experiments are presented.
Design of an image-distribution service from a clinical PACS
NASA Astrophysics Data System (ADS)
Gehring, Dale G.; Persons, Kenneth R.; Rothman, Melvyn L.; Felmlee, Joel P.; Gerhart, D. J.; Hangiandreou, Nicholas J.; Reardon, Frank J.; Shirk, M.; Forbes, Glenn S.; Williamson, Byrn, Jr.
1994-05-01
A PACS system has been developed through a multi-phase collaboration between the Mayo Clinic and IBM/Rochester. The current system has been fully integrated into the clinical practice of the Radiology Department for the primary purpose of digital image archival, retrieval, and networked workstation review. Work currently in progress includes the design and implementation of a gateway device for providing digital image data to third-party workstations, laser printers, and other devices, for users both within and outside of the Radiology Department.
1993-01-01
Deoxyribose nucleicacid DPP: Digital Post-Processor DREO Detence Research Establishment Ottawa RF: Radio Frequency TeO2 : tellurium dioxide TIC: Time... TeO2 is 620 m/s, a device with a 100-As aperture device is 62-mm long. To take advantage of the full interaction time of these Bragg cells, the whole...INCLUDED IN THE DIGITAL POST-PROCESSOR HARDWARE Characteristics of Bandwidth Center Frequency Bragg Cell glass (bulk 100 MHz 150 MHz interaction) iNbO3
NASA Astrophysics Data System (ADS)
Szplet, R.; Kalisz, J.; Jachna, Z.
2009-02-01
We present a time digitizer having 45 ps resolution, integrated in a field programmable gate array (FPGA) device. The time interval measurement is based on the two-stage interpolation method. A dual-edge two-phase interpolator is driven by the on-chip synthesized 250 MHz clock with precise phase adjustment. An improved dual-edge double synchronizer was developed to control the main counter. The nonlinearity of the digitizer's transfer characteristic is identified and utilized by the dedicated hardware code processor for the on-the-fly correction of the output data. Application of presented ideas has resulted in the measurement uncertainty of the digitizer below 70 ps RMS over the time interval ranging from 0 to 1 s. The use of the two-stage interpolation and a fast FIFO memory has allowed us to obtain the maximum measurement rate of five million measurements per second.
Rotary encoding device using polygonal mirror with diffraction gratings on each facet
NASA Technical Reports Server (NTRS)
Leviton, Douglas B. (Inventor)
1993-01-01
A device for position encoding of a rotating shaft in which a polygonal mirror having a number of facets is mounted to the shaft and a monochromatic light beam is directed towards the facets. The facets of the polygonal mirror each have a low line density diffraction grating to diffract the monochromatic light beam into a number of diffracted light beams such that a number of light spots are created on a linear array detector. An analog-to-digital converter is connected to the linear array detector for reading the position of the spots on the linear array detector means. A microprocessor with memory is connected to the analog-to-digital converter to hold and manipulate the data provided by the analog-to-digital converter on the position of the spots and to compute the position of the shaft based upon the data from the analog-to-digital converter.
Digital media in the home: technical and research challenges
NASA Astrophysics Data System (ADS)
Ribas-Corbera, Jordi
2005-03-01
This article attempts to identify some of the technology and research challenges facing the digital media industry in the future. We first discuss several trends in the industry, such as the rapid growth of broadband Internet networks and the emergence of networking and media-capable devices in the home. Next, we present technical challenges that result from these trends, such as effective media interoperability in devices, and provide a brief overview of Windows Media, which is one of the technologies in the market attempting to address these challenges. Finally, given these trends and the state of the art, we argue that further research on data compression, encoder optimization, and multi-format transcoding can potentially make a significant technical and business impact in digital media. We also explore the reasons that research on related techniques such as wavelets or scalable video coding is having a relatively minor impact in today"s practical digital media systems.
Collusion issue in video watermarking
NASA Astrophysics Data System (ADS)
Doerr, Gwenael; Dugelay, Jean-Luc
2005-03-01
Digital watermarking has first been introduced as a possible way to ensure intellectual property (IP) protection. However, fifteen years after its infancy, it is still viewed as a young technology and digital watermarking is far from being introduced in Digital Right Management (DRM) frameworks. A possible explanation is that the research community has so far mainly focused on the robustness of the embedded watermark and has almost ignored security aspects. For IP protection applications such as fingerprinting and copyright protection, the watermark should provide means to ensure some kind of trust in a non secure environment. To this end, security against attacks from malicious users has to be considered. This paper will focus on collusion attacks to evaluate security in the context of video watermarking. In particular, security pitfalls will be exhibited when frame-by-frame embedding strategies are enforced for video watermarking. Two alternative strategies will be surveyed: either eavesdropping the watermarking channel to identify some redundant hidden structure, or jamming the watermarking channel to wash out the embedded watermark signal. Finally, the need for a new brand of watermarking schemes will be highlighted if the watermark is to be released in a hostile environment, which is typically the case for IP protection applications.
Digital Control Technologies for Modular DC-DC Converters
NASA Technical Reports Server (NTRS)
Button, Robert M.; Kascak, Peter E.; Lebron-Velilla, Ramon
2002-01-01
Recent trends in aerospace Power Management and Distribution (PMAD) systems focus on using commercial off-the-shelf (COTS) components as standard building blocks. This move to more modular designs has been driven by a desire to reduce costs and development times, but is also due to the impressive power density and efficiency numbers achieved by today's commercial DC-DC converters. However, the PMAD designer quickly learns of the hidden "costs" of using COTS converters. The most significant cost is the required addition of external input filters to meet strict electromagnetic interference (MIAMI) requirements for space systems. In fact, the high power density numbers achieved by the commercial manufacturers are greatly due to the lack of necessary input filters included in the COTS module. The NASA Glenn Research Center is currently pursuing a digital control technology that addresses this problem with modular DC-DC converters. This paper presents the digital control technologies that have been developed to greatly reduce the input filter requirements for paralleled, modular DC-DC converters. Initial test result show that the input filter's inductor size was reduced by 75 percent, and the capacitor size was reduced by 94 percent while maintaining the same power quality specifications.
An Assessment of Pathology Resident Access to and Use of Technology: A Nationwide Survey.
Vallangeon, Bethany D; Hawley, Jeffrey S; Sloane, Richard; Bean, Sarah M
2017-03-01
- Current technologies including digital slide scanners and handheld devices can revolutionize clinical practice and pathology graduate medical education (GME). The extent to which these technologies are used in pathology GME is unknown. - To determine the types of technologies used, usage amount, and how they are integrated into pathology residency/fellowship programs nationwide. - A 40-question online survey for residents/fellows was developed and administered via the Research Electronic Data Capture System after institutional review board approval. - Fifty-two program directors (37%) gave permission for participation. One-hundred seventy-one responses were received (18% response rate). Most respondents have access to personal technology (laptop = 78% [134 of 171]), smartphone = 81% [139 of 171], tablet = 49% [84 of 171]), and Web-based digital slide collections (82%, 141 of 171). Few residents are provided electronic devices by their programs (laptop = 22% [38 of 171], smartphone = 0.5% [1 of 171], and tablet = 12% [21 of 171]). Fifty-nine percent have access to digital slide scanners, 33% have access to a program-created database of digitized slides, and 52% use telepathology. Fifteen percent have access to asynchronous learning. Of those with access to video-recorded conferences, 89% review them. Program size was significantly positively correlated with resident access to program-provided laptops (P = .02) and tablets (P < .001), digital slide scanners (P = .01), and telepathology (P = .001). Of all devices, program-provided laptops are used most for professional work (60.5% use this device for more than 5 hours per day). - Most residents report access to multiple types of innovative technology, but incorporation of these tools within pathology training programs is highly variable. Opportunities for incorporating innovative technologies exist and could be further explored.
Fixation Biases towards the Index Finger in Almost-Natural Grasping
Voudouris, Dimitris; Smeets, Jeroen B. J.; Brenner, Eli
2016-01-01
We use visual information to guide our grasping movements. When grasping an object with a precision grip, the two digits need to reach two different positions more or less simultaneously, but the eyes can only be directed to one position at a time. Several studies that have examined eye movements in grasping have found that people tend to direct their gaze near where their index finger will contact the object. Here we aimed at better understanding why people do so by asking participants to lift an object off a horizontal surface. They were to grasp the object with a precision grip while movements of their hand, eye and head were recorded. We confirmed that people tend to look closer to positions that a digit needs to reach more accurately. Moreover, we show that where they look as they reach for the object depends on where they were looking before, presumably because they try to minimize the time during which the eyes are moving so fast that no new visual information is acquired. Most importantly, we confirmed that people have a bias to direct gaze towards the index finger’s contact point rather than towards that of the thumb. In our study, this cannot be explained by the index finger contacting the object before the thumb. Instead, it appears to be because the index finger moves to a position that is hidden behind the object that is grasped, probably making this the place at which one is most likely to encounter unexpected problems that would benefit from visual guidance. However, this cannot explain the bias that was found in previous studies, where neither contact point was hidden, so it cannot be the only explanation for the bias. PMID:26766551
Real-time interactive simulation: using touch panels, graphics tablets, and video-terminal keyboards
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venhuizen, J.R.
1983-01-01
A Simulation Laboratory utilizing only digital computers for interactive computing must rely on CRT based graphics devices for output devices, and keyboards, graphics tablets, and touch panels, etc., for input devices. The devices all work well, with the combination of a CRT with a touch panel mounted on it as the most flexible combination of input/output devices for interactive simulation.
Afra, Pegah; Bruggers, Carol S.; Sweney, Matthew; Fagatele, Lilly; Alavi, Fareeha; Greenwald, Michael; Huntsman, Merodean; Nguyen, Khanhly; Jones, Jeremiah K.; Shantz, David; Bulaj, Grzegorz
2018-01-01
Digital health technologies for people with epilepsy (PWE) include internet-based resources and mobile apps for seizure management. Since non-pharmacological interventions, such as listening to specific Mozart's compositions, cognitive therapy, psychosocial and educational interventions were shown to reduce epileptic seizures, these modalities can be integrated into mobile software and delivered by mobile medical apps as digital therapeutics. Herein, we describe: (1) a survey study among PWE about preferences to use mobile software for seizure control, (2) a rationale for developing digital therapies for epilepsy, (3) creation of proof-of-concept mobile software intended for use as an adjunct digital therapeutic to reduce seizures, and (4) broader applications of digital therapeutics for the treatment of epilepsy and other chronic disorders. A questionnaire was used to survey PWE with respect to preferred features in a mobile app for seizure control. Results from the survey suggested that over 90% of responders would be interested in using a mobile app to manage their seizures, while 75% were interested in listening to specific music that can reduce seizures. To define digital therapeutic for the treatment of epilepsy, we designed and created a proof-of-concept mobile software providing digital content intended to reduce seizures. The rationale for all components of such digital therapeutic is described. The resulting web-based app delivered a combination of epilepsy self-care, behavioral interventions, medication reminders and the antiseizure music, such as the Mozart's sonata K.448. To improve long-term patient engagement, integration of mobile medical app with music and multimedia streaming via smartphones, tablets and computers is also discussed. This work aims toward development and regulatory clearance of software as medical device (SaMD) for seizure control, yielding the adjunct digital therapeutic for epilepsy, and subsequently a drug-device combination product together with specific antiseizure medications. Mobile medical apps, music, therapeutic video games and their combinations with prescription medications present new opportunities to integrate pharmacological and non-pharmacological interventions for PWE, as well as those living with other chronic disorders, including depression and pain. PMID:29780310
Afra, Pegah; Bruggers, Carol S; Sweney, Matthew; Fagatele, Lilly; Alavi, Fareeha; Greenwald, Michael; Huntsman, Merodean; Nguyen, Khanhly; Jones, Jeremiah K; Shantz, David; Bulaj, Grzegorz
2018-01-01
Digital health technologies for people with epilepsy (PWE) include internet-based resources and mobile apps for seizure management. Since non-pharmacological interventions, such as listening to specific Mozart's compositions, cognitive therapy, psychosocial and educational interventions were shown to reduce epileptic seizures, these modalities can be integrated into mobile software and delivered by mobile medical apps as digital therapeutics. Herein, we describe: (1) a survey study among PWE about preferences to use mobile software for seizure control, (2) a rationale for developing digital therapies for epilepsy, (3) creation of proof-of-concept mobile software intended for use as an adjunct digital therapeutic to reduce seizures, and (4) broader applications of digital therapeutics for the treatment of epilepsy and other chronic disorders. A questionnaire was used to survey PWE with respect to preferred features in a mobile app for seizure control. Results from the survey suggested that over 90% of responders would be interested in using a mobile app to manage their seizures, while 75% were interested in listening to specific music that can reduce seizures. To define digital therapeutic for the treatment of epilepsy, we designed and created a proof-of-concept mobile software providing digital content intended to reduce seizures. The rationale for all components of such digital therapeutic is described. The resulting web-based app delivered a combination of epilepsy self-care, behavioral interventions, medication reminders and the antiseizure music, such as the Mozart's sonata K.448. To improve long-term patient engagement, integration of mobile medical app with music and multimedia streaming via smartphones, tablets and computers is also discussed. This work aims toward development and regulatory clearance of software as medical device (SaMD) for seizure control, yielding the adjunct digital therapeutic for epilepsy, and subsequently a drug-device combination product together with specific antiseizure medications. Mobile medical apps, music, therapeutic video games and their combinations with prescription medications present new opportunities to integrate pharmacological and non-pharmacological interventions for PWE, as well as those living with other chronic disorders, including depression and pain.
PLATO--AN AUTOMATED TEACHING DEVICE.
ERIC Educational Resources Information Center
BITZER, D.; AND OTHERS
PLATO (PROGRAMED LOGIC FOR AUTOMATIC TEACHING OPERATION) IS A DEVICE FOR TEACHING A NUMBER OF STUDENTS INDIVIDUALLY BY MEANS OF A SINGLE, CENTRAL PURPOSE, DIGITAL COMPUTER. THE GENERAL ORGANIZATION OF EQUIPMENT CONSISTS OF A KEYSET FOR STUDENT RESPONSES, THE COMPUTER, STORAGE DEVICE (ELECTRIC BLACKBOARD), SLIDE SELECTOR (ELECTRICAL BOOK), AND TV…
Despont-Gros, Christelle; Bœuf, Christophe; Geissbuhler, Antoine; Lovis, Christian
2005-01-01
Evaluation of the technical feasibility of tight integration of the digital pen and paper technology in an existing computerized patient record.Technology: The digital pen is a normal pen able to record all actions of the user and to analyze a micro pattern printed on the paper. The digital paper is a normal paper printed with an almost invisible micro pattern of small dots encoding information such as position and identifiers. We report our experience in the implementation and the use of this technology in an existing large clinical information system for acquiring clinical information. It is possible to print uniquely identified forms using the digital paper technology. These forms can be pre-filled with clinical readable information about the patient. When care providers complete these forms using the digital pen, it is possible to acquire the data in a structured computerized patient record. The technology is easy to integrate in a component-based architecture based on Web Services. The digital pen and paper is a cost-effective technology that can be integrated in an existing clinical information system and allows fast and easy bedside clinical information acquisition without the need for an expensive infrastructure based on traditional portable devices or wireless devices.
Digital-Analog Hybrid Scheme and Its Application to Chaotic Random Number Generators
NASA Astrophysics Data System (ADS)
Yuan, Zeshi; Li, Hongtao; Miao, Yunchi; Hu, Wen; Zhu, Xiaohua
2017-12-01
Practical random number generation (RNG) circuits are typically achieved with analog devices or digital approaches. Digital-based techniques, which use field programmable gate array (FPGA) and graphics processing units (GPU) etc. usually have better performances than analog methods as they are programmable, efficient and robust. However, digital realizations suffer from the effect of finite precision. Accordingly, the generated random numbers (RNs) are actually periodic instead of being real random. To tackle this limitation, in this paper we propose a novel digital-analog hybrid scheme that employs the digital unit as the main body, and minimum analog devices to generate physical RNs. Moreover, the possibility of realizing the proposed scheme with only one memory element is discussed. Without loss of generality, we use the capacitor and the memristor along with FPGA to construct the proposed hybrid system, and a chaotic true random number generator (TRNG) circuit is realized, producing physical RNs at a throughput of Gbit/s scale. These RNs successfully pass all the tests in the NIST SP800-22 package, confirming the significance of the scheme in practical applications. In addition, the use of this new scheme is not restricted to RNGs, and it also provides a strategy to solve the effect of finite precision in other digital systems.
Interdisciplinary education in optics and photonics based on microcontrollers
NASA Astrophysics Data System (ADS)
Dreßler, Paul; Wielage, Heinz-Hermann; Haiss, Ulrich; Vauderwange, Oliver; Curticapean, Dan
2014-07-01
Not only is the number of new devices constantly increasing, but so is their application complexity and power. Most of their applications are in optics, photonics, acoustic and mobile devices. Working speed and functionality is achieved in most of media devices by strategic use of digital signal processors and microcontrollers of the new generation. Considering all these premises of media development dynamics, the authors present how to integrate microcontrollers and digital signal processors in the curricula of media technology lectures by using adequate content. This also includes interdisciplinary content that consists of using the acquired knowledge in media software. These entries offer a deeper understanding of photonics, acoustics and media engineering.
Tangible display systems: bringing virtual surfaces into the real world
NASA Astrophysics Data System (ADS)
Ferwerda, James A.
2012-03-01
We are developing tangible display systems that enable natural interaction with virtual surfaces. Tangible display systems are based on modern mobile devices that incorporate electronic image displays, graphics hardware, tracking systems, and digital cameras. Custom software allows the orientation of a device and the position of the observer to be tracked in real-time. Using this information, realistic images of surfaces with complex textures and material properties illuminated by environment-mapped lighting, can be rendered to the screen at interactive rates. Tilting or moving in front of the device produces realistic changes in surface lighting and material appearance. In this way, tangible displays allow virtual surfaces to be observed and manipulated as naturally as real ones, with the added benefit that surface geometry and material properties can be modified in real-time. We demonstrate the utility of tangible display systems in four application areas: material appearance research; computer-aided appearance design; enhanced access to digital library and museum collections; and new tools for digital artists.
Engineering modular and orthogonal genetic logic gates for robust digital-like synthetic biology.
Wang, Baojun; Kitney, Richard I; Joly, Nicolas; Buck, Martin
2011-10-18
Modular and orthogonal genetic logic gates are essential for building robust biologically based digital devices to customize cell signalling in synthetic biology. Here we constructed an orthogonal AND gate in Escherichia coli using a novel hetero-regulation module from Pseudomonas syringae. The device comprises two co-activating genes hrpR and hrpS controlled by separate promoter inputs, and a σ(54)-dependent hrpL promoter driving the output. The hrpL promoter is activated only when both genes are expressed, generating digital-like AND integration behaviour. The AND gate is demonstrated to be modular by applying new regulated promoters to the inputs, and connecting the output to a NOT gate module to produce a combinatorial NAND gate. The circuits were assembled using a parts-based engineering approach of quantitative characterization, modelling, followed by construction and testing. The results show that new genetic logic devices can be engineered predictably from novel native orthogonal biological control elements using quantitatively in-context characterized parts. © 2011 Macmillan Publishers Limited. All rights reserved.
ERIC Educational Resources Information Center
Lanham, Richard A.
1989-01-01
Traces the early history of the electronic digital computer and the viewpoints held concerning the computer from its inception to its present status. Highlights three key words ("mimesis,""topic," and "decorum") to develop the rhetoricality of the personal computer as a communications device. (KEH)
37 CFR 360.25 - Copies of claims.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Section 360.25 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio... claim to digital audio recording devices and media royalty payments. ...
37 CFR 360.25 - Copies of claims.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Section 360.25 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio... claim to digital audio recording devices and media royalty payments. ...
37 CFR 360.25 - Copies of claims.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 360.25 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio... claim to digital audio recording devices and media royalty payments. ...
37 CFR 360.25 - Copies of claims.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Section 360.25 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio... claim to digital audio recording devices and media royalty payments. ...
37 CFR 360.25 - Copies of claims.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Section 360.25 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio... claim to digital audio recording devices and media royalty payments. ...
Digital Health Intervention for Asthma: Patient-Reported Value and Usability.
Merchant, Rajan; Inamdar, Rubina; Henderson, Kelly; Barrett, Meredith; Su, Jason G; Riley, Jesika; Van Sickle, David; Stempel, David
2018-06-04
Although digital health tools are increasingly recognized as effective in improving clinical outcomes such as asthma control and medication adherence, few studies have assessed patient experiences and perception of value. The aim of this study was to evaluate patient satisfaction, perception of usability and value, and desire to continue after 12 months of using a digital health intervention to support asthma management. Participants were enrolled in a randomized controlled study evaluating the impact of a digital health platform for asthma management. Participants used electronic inhaler sensors to track medication use and accessed their information in a digital health platform. Electronic surveys were administered to intervention arm participants aged 12 years and older after 12 months of use. The survey assessed asthma control, patient satisfaction with the sensor device, and perception of the usability and value of the digital health platform through closed-ended and open-ended questions. Logistic regression models were used to assess the impact of participants' characteristics on survey completion, satisfaction, and perception of value. Of the 207 intervention arm participants aged 12 years and older, 89 submitted survey responses (42.9% response rate). Of these 89 participants, 70 reported being very satisfied (79%, 70/89) or somewhat satisfied (20%, 18/89) with the inhaler sensor device. Moreover, 93% (83/89) expressed satisfaction with the reports, and 90% (80/89) found the information from the reports useful for learning about their asthma. In addition, 72% (64/89) of the participants reported that they were interested in continuing to use the sensor and platform beyond the study. There were no significant differences in satisfaction with the device or the platform across participants' characteristics, including device type, age, sex, insurance type, asthma control, or syncing history; however, participants with smartphones and longer participation were more likely to take the survey. Electronic sensors and a digital health platform were well received by participants who reported satisfaction and perceived value. These results were consistent across multiple participants' characteristics. These findings can add to a limited literature to keep improving digital health interventions and ensure the meaningful and enduring impact on patient outcomes. ©Rajan Merchant, Rubina Inamdar, Kelly Henderson, Meredith Barrett, Jason G Su, Jesika Riley, David Van Sickle, David Stempel. Originally published in JMIR Mhealth and Uhealth (http://mhealth.jmir.org), 04.06.2018.
Exploring How Digital Media Technology Can Foster Saudi EFL Students' English Language Learning
ERIC Educational Resources Information Center
Altawil, Abdulmohsin
2016-01-01
Digital media technology has become an integral part of daily life for almost all young students, and for the majority of Saudi EFL (English as a Foreign Language) students. Digital media technology may not be limited to one or two kinds; it has various types such as software and programs, devices, application, websites, social media tools, etc.…
Next-generation digital camera integration and software development issues
NASA Astrophysics Data System (ADS)
Venkataraman, Shyam; Peters, Ken; Hecht, Richard
1998-04-01
This paper investigates the complexities associated with the development of next generation digital cameras due to requirements in connectivity and interoperability. Each successive generation of digital camera improves drastically in cost, performance, resolution, image quality and interoperability features. This is being accomplished by advancements in a number of areas: research, silicon, standards, etc. As the capabilities of these cameras increase, so do the requirements for both hardware and software. Today, there are two single chip camera solutions in the market including the Motorola MPC 823 and LSI DCAM- 101. Real time constraints for a digital camera may be defined by the maximum time allowable between capture of images. Constraints in the design of an embedded digital camera include processor architecture, memory, processing speed and the real-time operating systems. This paper will present the LSI DCAM-101, a single-chip digital camera solution. It will present an overview of the architecture and the challenges in hardware and software for supporting streaming video in such a complex device. Issues presented include the development of the data flow software architecture, testing and integration on this complex silicon device. The strategy for optimizing performance on the architecture will also be presented.
Tablet PC interaction with digital micromirror device (DMD)
NASA Astrophysics Data System (ADS)
Refai, Hakki H.; Dahshan, Mostafa H.; Sluss, James J., Jr.
2007-02-01
Digital light processing (DLP) is an innovative display technology that uses an optical switch array, known as a digital micromirror device (DMD), which allows digital control of light. To date, DMDs have been used primarily as high-speed spatial light modulators for projector applications. A tablet PC is a notebook or slate-shaped mobile PC. Its touch screen or digitizing tablet technology allows the user to operate the notebook with a stylus or digital pen instead of using a keyboard or mouse. In this paper, we describe an interface solution that translates any sketch on the tablet PC screen to an identical mirror-copy over the cross-section of the DMD micromirrors such that the image of the sketch can be projected onto a special screen. An algorithm has been created to control each single micromirror of the hundreds of thousands of micromirrors that cover the DMD surface. We demonstrate the successful application of a DMD to a high-speed two-dimensional (2D) scanning environment, acquiring the data from the tablet screen and launching its contents to the projection screen; with very high accuracy up to 13.68 μm x 13.68 μm of mirror pitch.
SuperState: a computer program for the control of operant behavioral experimentation.
Zhang, Fuqiang
2006-09-15
Operant behavioral researches require precise control of experimental devices for delivering stimuli and monitoring behavioral responses. The author developed a software solution named SuperState for controlling hardware devices and running reinforcement schedules. The Microsoft Windows compatible software was written by use of an object-oriented programming language Borland Delphi 5.0, which has simplified the programming of the application. SuperState is a stand-alone easy-to-use green software, without the need for the experimenter to master any scripting languages. It features: (1) control of multiple operant cages running independent reinforcement schedules; (2) enough cage devices (16 digital inputs and 16 digital outputs for each cage) suitable for the need of most operant behavioral equipments; (3) control of most standard ISA-type digital interface cards including Med-Associates Super-port cards and a PCI-type card AC6412, and highly expandable to support other PCI-type interface cards; (4) high-resolution device control (1ms); (5) a built-in real-time cumulative recorder; (6) extensive data analyzing including event recorder, cumulative recorder, block analyzing; the summarized results can be transferred easily to Microsoft Excel spreadsheets through the Clipboard.
Effective use of remote sensing products in litigation
NASA Technical Reports Server (NTRS)
Jaynes, R. A.
1983-01-01
A boiled-down version of major legal principles affecting the admissibility of data and products from remote sensing devices is presented. It is suggested that enhancements or classifications of digital data (from scanning devices or from digitized aerial photography) be proffered as evidence in a fashion similar to the manner in which maps from photogrammetric techniques are introduced as evidence. Every effort should be made to illucidate the processes by which digital data are analytically treated or manipulated. Remote sensing expert witnesses should be practiced in providing concise and clear explanations of both data and methods. Special emphasis should be placed on being prepared to provide a detailed accounting of steps taken to calibrate and verify spectral characteristics with ground truth.
An automatic analyzer of solid state nuclear track detectors using an optic RAM as image sensor
NASA Astrophysics Data System (ADS)
Staderini, Enrico Maria; Castellano, Alfredo
1986-02-01
An optic RAM is a conventional digital random access read/write dynamic memory device featuring a quartz windowed package and memory cells regularly ordered on the chip. Such a device is used as an image sensor because each cell retains data stored in it for a time depending on the intensity of the light incident on the cell itself. The authors have developed a system which uses an optic RAM to acquire and digitize images from electrochemically etched CR39 solid state nuclear track detectors (SSNTD) in the track count rate up to 5000 cm -2. On the digital image so obtained, a microprocessor, with appropriate software, performs image analysis, filtering, tracks counting and evaluation.
Bridging the digital divide: mobile access to personal health records among patients with diabetes.
Graetz, Ilana; Huang, Jie; Brand, Richard J; Hsu, John; Yamin, Cyrus K; Reed, Mary E
2018-01-01
Some patients lack regular computer access and experience a digital divide that causes them to miss internet-based health innovations. The diffusion of smartphones has increased internet access across the socioeconomic spectrum, and increasing the channels through which patients can access their personal health records (PHRs) could help bridge the divide in PHR use. We examined PHR use through a computer-based Web browser or mobile device. Cross-sectional historical cohort analysis. Among adult patients in the diabetes registry of an integrated healthcare delivery system, we studied the devices used to access their PHR during 2016. Among 267,208 patients with diabetes, 68.1% used the PHR in 2016; 60.6% of all log-ins were via computer and 39.4% were via mobile device. Overall, 63.9% used it from both a computer and mobile device, 29.6% used only a computer, and 6.5% used only a mobile device. After adjustment, patients who were black, Hispanic, or Asian; lived in lower socioeconomic status (SES) neighborhoods; or had lower engagement were all significantly more likely to use the PHR only from a mobile device (P <.05). Patients using the PHR only via mobile device used it less frequently. Mobile-ready PHRs may increase access among patients facing a digital divide in computer use, disproportionately reaching racial/ethnic minorities and lower SES patients. Nonetheless, even with a mobile-optimized and app-accessible PHR, differences in PHR use by race/ethnicity and SES remain. Continued efforts are needed to increase equitable access to PHRs among patients with chronic conditions.
Silverman, Erin P; Carnaby-Mann, Giselle; Pitts, Teresa; Davenport, Paul; Okun, Michael S; Sapienza, Christine
2014-05-01
Dysphagia and aspiration pneumonia are two causes of morbidity in Parkinson disease (PD). In PD, impaired airway clearance can lead to penetration of foreign material, resulting in a high prevalence of aspiration pneumonia and death. This study examines three different devices for measurement of peak airflow during voluntary cough in healthy control subjects and those with PD. Two simple and low-cost devices for measuring peak cough airflow were compared with the "gold standard" pneumotachograph. Thirty-five healthy control subjects and 35 individuals with PD produced voluntary cough at three perceived strengths (weak, moderate, and strong cough) for each of the three devices. A significant difference in mean peak cough airflow was demonstrated for disease (F[1,56] = 4.0, P < .05) and sex (F[1,56] = 9.59, P < .003) across devices. The digital and analog meters were comparable to the gold standard demonstrating no significant difference (statistical) by device (digital vs analog) in receiver operating characteristic curve analysis. Both devices were discriminative of the presence of PD. The analog and digital peak airflow meters are suitable alternatives to the gold standard pneumotachograph due to their low cost, portability, ease of use, and high sensitivity relative to normative peak cough airflows. Voluntary cough airflow measures may serve as a noninvasive means of screening for aspiration risk in target populations. Additionally, quantification of cough strength through use of predetermined limens for weak, moderate, and strong cough may assist clinicians in better describing and tracking cough strength as a contributing factor to aspiration risk.
Carnaby-Mann, Giselle; Pitts, Teresa; Davenport, Paul; Okun, Michael S.; Sapienza, Christine
2014-01-01
Background: Dysphagia and aspiration pneumonia are two causes of morbidity in Parkinson disease (PD). In PD, impaired airway clearance can lead to penetration of foreign material, resulting in a high prevalence of aspiration pneumonia and death. This study examines three different devices for measurement of peak airflow during voluntary cough in healthy control subjects and those with PD. Two simple and low-cost devices for measuring peak cough airflow were compared with the “gold standard” pneumotachograph. Methods: Thirty-five healthy control subjects and 35 individuals with PD produced voluntary cough at three perceived strengths (weak, moderate, and strong cough) for each of the three devices. Results: A significant difference in mean peak cough airflow was demonstrated for disease (F[1,56] = 4.0, P < .05) and sex (F[1,56] = 9.59, P < .003) across devices. The digital and analog meters were comparable to the gold standard demonstrating no significant difference (statistical) by device (digital vs analog) in receiver operating characteristic curve analysis. Both devices were discriminative of the presence of PD. Conclusions: The analog and digital peak airflow meters are suitable alternatives to the gold standard pneumotachograph due to their low cost, portability, ease of use, and high sensitivity relative to normative peak cough airflows. Voluntary cough airflow measures may serve as a noninvasive means of screening for aspiration risk in target populations. Additionally, quantification of cough strength through use of predetermined limens for weak, moderate, and strong cough may assist clinicians in better describing and tracking cough strength as a contributing factor to aspiration risk. PMID:24264124
A Spacecraft Housekeeping System-on-Chip in a Radiation Hardened Structured ASIC
NASA Technical Reports Server (NTRS)
Suarez, George; DuMonthier, Jeffrey J.; Sheikh, Salman S.; Powell, Wesley A.; King, Robyn L.
2012-01-01
Housekeeping systems are essential to health monitoring of spacecraft and instruments. Typically, sensors are distributed across various sub-systems and data is collected using components such as analog-to-digital converters, analog multiplexers and amplifiers. In most cases programmable devices are used to implement the data acquisition control and storage, and the interface to higher level systems. Such discrete implementations require additional size, weight, power and interconnect complexity versus an integrated circuit solution, as well as the qualification of multiple parts. Although commercial devices are readily available, they are not suitable for space applications due the radiation tolerance and qualification requirements. The Housekeeping System-o n-A-Chip (HKSOC) is a low power, radiation hardened integrated solution suitable for spacecraft and instrument control and data collection. A prototype has been designed and includes a wide variety of functions including a 16-channel analog front-end for driving and reading sensors, analog-to-digital and digital-to-analog converters, on-chip temperature sensor, power supply current sense circuits, general purpose comparators and amplifiers, a 32-bit processor, digital I/O, pulse-width modulation (PWM) generators, timers and I2C master and slave serial interfaces. In addition, the device can operate in a bypass mode where the processor is disabled and external logic is used to control the analog and mixed signal functions. The device is suitable for stand-alone or distributed systems where multiple chips can be deployed across different sub-systems as intelligent nodes with computing and processing capabilities.
NASA Technical Reports Server (NTRS)
Cochran, Donna J.; Boutte, Alvin J.; Chen, Dakai; Pellish, Jonathan A.; Ladbury, Raymond L.; Casey, Megan C.; Campola, Michael J.; Wilcox, Edward P.; Obryan, Martha V.; LaBel, Kenneth A.;
2012-01-01
Vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage is studied. Devices tested include optoelectronics, digital, analog, linear, and hybrid devices.
Low-Actuation Voltage MEMS Digital-to-Analog Converter with Parylene Spring Structures.
Ma, Cheng-Wen; Lee, Fu-Wei; Liao, Hsin-Hung; Kuo, Wen-Cheng; Yang, Yao-Joe
2015-08-28
We propose an electrostatically-actuated microelectromechanical digital-to-analog converter (M-DAC) device with low actuation voltage. The spring structures of the silicon-based M-DAC device were monolithically fabricated using parylene-C. Because the Young's modulus of parylene-C is considerably lower than that of silicon, the electrostatic microactuators in the proposed device require much lower actuation voltages. The actuation voltage of the proposed M-DAC device is approximately 6 V, which is less than one half of the actuation voltages of a previously reported M-DAC equipped with electrostatic microactuators. The measured total displacement of the proposed three-bit M-DAC is nearly 504 nm, and the motion step is approximately 72 nm. Furthermore, we demonstrated that the M-DAC can be employed as a mirror platform with discrete displacement output for a noncontact surface profiling system.
Tools virtualization for command and control systems
NASA Astrophysics Data System (ADS)
Piszczek, Marek; Maciejewski, Marcin; Pomianek, Mateusz; Szustakowski, Mieczysław
2017-10-01
Information management is an inseparable part of the command process. The result is that the person making decisions at the command post interacts with data providing devices in various ways. Tools virtualization process can introduce a number of significant modifications in the design of solutions for management and command. The general idea involves replacing physical devices user interface with their digital representation (so-called Virtual instruments). A more advanced level of the systems "digitalization" is to use the mixed reality environments. In solutions using Augmented reality (AR) customized HMI is displayed to the operator when he approaches to each device. Identification of device is done by image recognition of photo codes. Visualization is achieved by (optical) see-through head mounted display (HMD). Control can be done for example by means of a handheld touch panel. Using the immersive virtual environment, the command center can be digitally reconstructed. Workstation requires only VR system (HMD) and access to information network. Operator can interact with devices in such a way as it would perform in real world (for example with the virtual hands). Because of their procedures (an analysis of central vision, eye tracking) MR systems offers another useful feature of reducing requirements for system data throughput. Due to the fact that at the moment we focus on the single device. Experiments carried out using Moverio BT-200 and SteamVR systems and the results of experimental application testing clearly indicate the ability to create a fully functional information system with the use of mixed reality technology.
NASA Technical Reports Server (NTRS)
Topper, Alyson D.; Campola, Michael J.; Chen, Dakai; Casey, Megan C.; Yau, Ka-Yen; Cochran, Donna J.; LaBel, Kenneth A.; Ladbury, Raymond L.; Lauenstein, Jean-Marie; Mondy, Timothy K.;
2017-01-01
Total ionizing dose and displacement damage testing was performed to characterize and determine the suitability of candidate electronics for NASA space utilization. Devices tested include optoelectronics, digital, analog, linear bipolar devices, and hybrid devices.
A Computer Story: Complexity from Simplicity
ERIC Educational Resources Information Center
DeLeo, Gary; Weidenhammer, Amanda; Wecht, Kristen
2012-01-01
In this technological age, digital devices are conspicuous examples of extraordinary complexity. When a user clicks on computer icons or presses calculator buttons, these devices channel electricity through a complex system of decision-making circuits. Yet, in spite of this remarkable complexity, the hearts of these devices are components that…
Bring Your Own Device: Parental Guidance (PG) Suggested
ERIC Educational Resources Information Center
Kiger, Derick; Herro, Dani
2015-01-01
Educators are incorporating students' mobile devices into the schooling experience via Bring Your Own Device (BYOD) initiatives. This is advantageous for many reasons, most notably, improving access to Internet resources and digital tools in support of teaching and learning. Obtaining parental support is key to BYOD success. Therefore, this study…
78 FR 77209 - Accessibility of User Interfaces, and Video Programming Guides and Menus
Federal Register 2010, 2011, 2012, 2013, 2014
2013-12-20
... user interfaces on digital apparatus and video programming guides and menus on navigation devices for... apparatus and navigation devices used to view video programming. The rules we adopt here will effectuate...--that is, devices and other equipment used by consumers to access multichannel video programming and...
Detection of Objects Hidden in Highly Scattering Media Using Time-Gated Imaging Methods
NASA Technical Reports Server (NTRS)
Galland, Pierre A.; Wang, L.; Liang, X.; Ho, P. P.; Alfano, R. R.
2000-01-01
Non-intrusive and non-invasive optical imaging techniques has generated great interest among researchers for their potential applications to biological study, device characterization, surface defect detection, and jet fuel dynamics. Non-linear optical parametric amplification gate (NLOPG) has been used to detect back-scattered images of objects hidden in diluted Intralipid solutions. To directly detect objects hidden in highly scattering media, the diffusive component of light needs to be sorted out from early arrived ballistic and snake photons. In an optical imaging system, images are collected in transmission or back-scattered geometry. The early arrival photons in the transmission approach, always carry the direct information of the hidden object embedded in the turbid medium. In the back-scattered approach, the result is not so forth coming. In the presence of a scattering host, the first arrival photons in back-scattered approach will be directly photons from the host material. In the presentation, NLOPG was applied to acquire time resolved back-scattered images under the phase matching condition. A time-gated amplified signal was obtained through this NLOPG process. The system's gain was approximately 100 times. The time-gate was achieved through phase matching condition where only coherent photons retain their phase. As a result, the diffusive photons, which were the primary contributor to the background, were removed. With a large dynamic range and high resolution, time-gated early light imaging has the potential for improving rocket/aircraft design by determining jets shape and particle sizes. Refinements to these techniques may enable drop size measurements in the highly scattering, optically dense region of multi-element rocket injectors. These types of measurements should greatly enhance the design of stable, and higher performing rocket engines.
The Early Years: Integrating Digital Tools
ERIC Educational Resources Information Center
Ashbrook, Peggy
2017-01-01
This column discusses resources and science topics related to students in grades preK to 2. This month's issue discusses how digital media and robotics fit into the early childhood curriculum, and how time on devices supports learning goals and developmentally appropriate practice.
Plasma digital density determining device
Sprott, Julien C.; Lovell, Thomas W.; Holly, Donald J.
1976-01-01
The density of a decaying plasma in an electrically conducting enclosure is determined by applying an excitation to the cavity formed by the enclosure and counting digitally the number of resonant frequencies traversed by the combination of the cavity and the decaying plasma.
The Acceptance of Smartphone as a Mobile Learning Tool: Students of Business Studies in Bangladesh
ERIC Educational Resources Information Center
Ahmed, Mazharuddin Syed; Kabir, Akramul
2018-01-01
Mobile devices have become attractive learning devices for education. It is common to assume that our current undergraduates are digital natives who are naturally proficient and expert in the use of technology so do mobile devices such as Smartphone. Smartphone has become more of a computing device and are multi-functional, hence, its use as a…
Silicon Micromachining in RF and Photonic Applications
NASA Technical Reports Server (NTRS)
Lin, Tsen-Hwang; Congdon, Phil; Magel, Gregory; Pang, Lily; Goldsmith, Chuck; Randall, John; Ho, Nguyen
1995-01-01
Texas Instruments (TI) has developed membrane and micromirror devices since the late 1970s. An eggcrate space membrane was used as the spatial light modulator in the early years. Discrete micromirrors supported by cantilever beams created a new era for micromirror devices. Torsional micromirror and flexure-beam micromirror devices were promising for mass production because of their stable supports. TI's digital torsional micromirror device is an amplitude modulator (known as the digital micromirror device (DMD) and is in production development, discussed elsewhere. We also use a torsional device for a 4 x 4 fiber-optic crossbar switch in a 2 cm x 2 cm package. The flexure-beam micromirror device is an analog phase modulator and is considered more efficient than amplitude modulators for use in optical processing systems. TI also developed millimeter-sized membranes for integrated optical switches for telecommunication and network applications. Using a member in radio frequency (RF) switch applications is a rapidly growing area because of the micromechanical device performance in microsecond-switching characteristics. Our preliminary membrane RF switch test structure results indicate promising speed and RF switching performance. TI collaborated with MIT for modeling of metal-based micromachining.
Sequential Pattern Detection and Time Series Models for Predicting IED Attacks
2009-03-01
customer purchases spaghetti sauce at the grocery store, do they also purchase some kind of meat and pasta noodles ? Knowing what items a shopper tends...such as the mileage, the number of passengers that can fit in the car, and the year the car was manufactured . The number of hidden nodes are...technology weapons that are inexpensive to manufacture and do not require extensive training to deploy. An improvised explosive device (IED) 28 is a
Development of High Resolution Eddy Current Imaging Using an Electro-Mechanical Sensor (Postprint)
2011-08-01
Primdahl, F., 1979, “The Fluxgate Magnetometer ,” J. Phys. E: Sci. Instrum., Vol. 12: 241-253. 13. A. Abedi, J. J. Fellenstein, A. J. Lucas, and J. P...Issues 1-2, Pages 203-206 (2006). 11. Ripka, P., 1992, Review of Fluxgate Sensors, Sensors and Actuators, A. 33, Elsevier Sequoia: 129-141. 12...Wikswo, Jr., “A superconducting quantum interference device magnetometer system for quantitative analysis and imaging of hidden corrosion activity in
A look inside the actuarial black box.
Math, S E; Youngerman, H
1992-12-01
Hospital executives often rely on actuaries (and their "black boxes") to determine self-insurance program liabilities and funding contributions. Typically, the hospital supplies the actuary with a myriad of statistics, and eventually the hospital receives a liability estimate and recommended funding level. The mysterious actuarial calculations that occur in between data reporting and receipt of the actuary's report are akin to a black box--a complicated device whose internal mechanism is hidden from or mysterious to the user.
Two-Way Communication Using RFID Equipment and Techniques
NASA Technical Reports Server (NTRS)
Jedry, Thomas; Archer, Eric
2007-01-01
Equipment and techniques used in radio-frequency identification (RFID) would be extended, according to a proposal, to enable short-range, two-way communication between electronic products and host computers. In one example of a typical contemplated application, the purpose of the short-range radio communication would be to transfer image data from a user s digital still or video camera to the user s computer for recording and/or processing. The concept is also applicable to consumer electronic products other than digital cameras (for example, cellular telephones, portable computers, or motion sensors in alarm systems), and to a variety of industrial and scientific sensors and other devices that generate data. Until now, RFID has been used to exchange small amounts of mostly static information for identifying and tracking assets. Information pertaining to an asset (typically, an object in inventory to be tracked) is contained in miniature electronic circuitry in an RFID tag attached to the object. Conventional RFID equipment and techniques enable a host computer to read data from and, in some cases, to write data to, RFID tags, but they do not enable such additional functions as sending commands to, or retrieving possibly large quantities of dynamic data from, RFID-tagged devices. The proposal would enable such additional functions. The figure schematically depicts an implementation of the proposal for a sensory device (e.g., a digital camera) that includes circuitry that converts sensory information to digital data. In addition to the basic sensory device, there would be a controller and a memory that would store the sensor data and/or data from the controller. The device would also be equipped with a conventional RFID chipset and antenna, which would communicate with a host computer via an RFID reader. The controller would function partly as a communication interface, implementing two-way communication protocols at all levels (including RFID if needed) between the sensory device and the memory and between the host computer and the memory. The controller would perform power V
A Real-Time Cardiac Arrhythmia Classification System with Wearable Sensor Networks
Hu, Sheng; Wei, Hongxing; Chen, Youdong; Tan, Jindong
2012-01-01
Long term continuous monitoring of electrocardiogram (ECG) in a free living environment provides valuable information for prevention on the heart attack and other high risk diseases. This paper presents the design of a real-time wearable ECG monitoring system with associated cardiac arrhythmia classification algorithms. One of the striking advantages is that ECG analog front-end and on-node digital processing are designed to remove most of the noise and bias. In addition, the wearable sensor node is able to monitor the patient's ECG and motion signal in an unobstructive way. To realize the real-time medical analysis, the ECG is digitalized and transmitted to a smart phone via Bluetooth. On the smart phone, the ECG waveform is visualized and a novel layered hidden Markov model is seamlessly integrated to classify multiple cardiac arrhythmias in real time. Experimental results demonstrate that the clean and reliable ECG waveform can be captured in multiple stressed conditions and the real-time classification on cardiac arrhythmia is competent to other workbenches. PMID:23112746
Villa, Francesco
1982-01-01
Method and apparatus for sequentially scanning a plurality of target elements with an electron scanning beam modulated in accordance with variations in a high-frequency analog signal to provide discrete analog signal samples representative of successive portions of the analog signal; coupling the discrete analog signal samples from each of the target elements to a different one of a plurality of high speed storage devices; converting the discrete analog signal samples to equivalent digital signals; and storing the digital signals in a digital memory unit for subsequent measurement or display.
Digital imaging for dental caries.
Wenzel, A
2000-04-01
Laboratory studies show that digital intraoral radiography systems are as accurate as dental film for the detection of caries when a good-quality image is obtained, although more re-takes might be necessary because of positioning errors with the digital systems, particularly the charge-coupled device sensors. The phosphor plate is more comfortable for the patient than nondigital systems, and the dose can be further reduced with the storage phosphors. Cross-contamination does not pose a problem with digital systems if simple hygiene procedures are observed.
3D Digital Smile Design With a Mobile Phone and Intraoral Optical Scanner.
Daher, René; Ardu, Stefano; Vjero, Osela; Krejci, Ivo
2018-06-01
Extraoral facial scanning using a mobile phone has emerged as a viable, cost-effective option for certain applications not requiring high precision, such as patient education and 3-dimensional (3D) digital smile design. This technological development is particularly promising for general practitioners (GPs) who may not be able to invest in expensive,complex digital impressioning devices. This article describes and illustrates a relatively simple and accessible workflow that avails digital 3D facial scanning benefits to GPs.
Initial Data of Digital Correlation ECE with a Giga Hertz Sampling Digitizer
NASA Astrophysics Data System (ADS)
Tsuchiya, Hayato; Inagaki, Shigeru; Tokuzawa, Tokihiko; Nagayama, Yoshio
2015-03-01
The proposed Digital Correlation ECE (DCECE) technique is applied in Large Helical Device. DCECE is realized by the use of the Giga Hertz Sampling Digitizer. The waveform of intermediate frequency band of ECE, whose frequency is several giga hertz, can be discretized and saved directly. The discretized IF data can be used for the analysis of correlation ECE with arbitrary parameter of spatial resolution and temporal resolution. In this paper, the characteristic of DCECE and initial Data in LHD is introduced.
Opto-digital spectrum encryption by using Baker mapping and gyrator transform
NASA Astrophysics Data System (ADS)
Chen, Hang; Zhao, Jiguang; Liu, Zhengjun; Du, Xiaoping
2015-03-01
A concept of spectrum information hidden technology is proposed in this paper. We present an optical encryption algorithm for hiding both the spatial and spectrum information by using the Baker mapping in gyrator transform domains. The Baker mapping is introduced for scrambling the every single band of the hyperspectral image before adding the random phase functions. Subsequently, three thin cylinder lenses are controlled by PC for implementing the gyrator transform. The amplitude and phase information in the output plane can be regarded as the encrypted information and main key. Some numerical simulations are made to test the validity and capability of the proposed encryption algorithm.
Fingerprint image enhancement by differential hysteresis processing.
Blotta, Eduardo; Moler, Emilce
2004-05-10
A new method to enhance defective fingerprints images through image digital processing tools is presented in this work. When the fingerprints have been taken without any care, blurred and in some cases mostly illegible, as in the case presented here, their classification and comparison becomes nearly impossible. A combination of spatial domain filters, including a technique called differential hysteresis processing (DHP), is applied to improve these kind of images. This set of filtering methods proved to be satisfactory in a wide range of cases by uncovering hidden details that helped to identify persons. Dactyloscopy experts from Policia Federal Argentina and the EAAF have validated these results.
CDC Vital Signs: Preventing Melanoma
... not use the device. Include warning statements in marketing materials about the risk of using the device. ... MB] en Español [PDF – 1.16 MB] CDC Digital Press Kit Read the MMWR Science Clips Language: ...
Detection of cough signals in continuous audio recordings using hidden Markov models.
Matos, Sergio; Birring, Surinder S; Pavord, Ian D; Evans, David H
2006-06-01
Cough is a common symptom of many respiratory diseases. The evaluation of its intensity and frequency of occurrence could provide valuable clinical information in the assessment of patients with chronic cough. In this paper we propose the use of hidden Markov models (HMMs) to automatically detect cough sounds from continuous ambulatory recordings. The recording system consists of a digital sound recorder and a microphone attached to the patient's chest. The recognition algorithm follows a keyword-spotting approach, with cough sounds representing the keywords. It was trained on 821 min selected from 10 ambulatory recordings, including 2473 manually labeled cough events, and tested on a database of nine recordings from separate patients with a total recording time of 3060 min and comprising 2155 cough events. The average detection rate was 82% at a false alarm rate of seven events/h, when considering only events above an energy threshold relative to each recording's average energy. These results suggest that HMMs can be applied to the detection of cough sounds from ambulatory patients. A postprocessing stage to perform a more detailed analysis on the detected events is under development, and could allow the rejection of some of the incorrectly detected events.
Optimize Short Term load Forcasting Anomalous Based Feed Forward Backpropagation
NASA Astrophysics Data System (ADS)
Mulyadi, Y.; Abdullah, A. G.; Rohmah, K. A.
2017-03-01
This paper contains the Short-Term Load Forecasting (STLF) using artificial neural network especially feed forward back propagation algorithm which is particularly optimized in order to getting a reduced error value result. Electrical load forecasting target is a holiday that hasn’t identical pattern and different from weekday’s pattern, in other words the pattern of holiday load is an anomalous. Under these conditions, the level of forecasting accuracy will be decrease. Hence we need a method that capable to reducing error value in anomalous load forecasting. Learning process of algorithm is supervised or controlled, then some parameters are arranged before performing computation process. Momentum constant a value is set at 0.8 which serve as a reference because it has the greatest converge tendency. Learning rate selection is made up to 2 decimal digits. In addition, hidden layer and input component are tested in several variation of number also. The test result leads to the conclusion that the number of hidden layer impact on the forecasting accuracy and test duration determined by the number of iterations when performing input data until it reaches the maximum of a parameter value.
ERIC Educational Resources Information Center
Brown, Timothy T.
2016-01-01
In this issue, Cavanaugh, Giapponi, and Golden (2016) have discussed the new prominent role of digital devices in the lives of students; the possible impact of these widely-used technologies on developing, learning minds; and the relevance of new cognitive neuroscience research and technologies for better understanding the potential effects of…
Children's response to a commercial back-up warning device.
Sapien, R E; Widman Roux, J; Fullerton-Gleason, L
2003-03-01
To determine preschool children's response to a commercial back-up warning alarm in a mock setting of an automobile backing up. Preschool parking lot in Albuquerque, New Mexico, USA. With subjects acting as their own controls, 33 preschoolers were asked to walk behind a stationary vehicle twice. The first time, the control, no warning sound was emitted from the vehicle. The second time, the vehicle was placed in reverse gear triggering an alarm. Children's responses were recorded by a hidden video camera. Avoidance behavior by the child was considered a positive response. Location and distance to where the response occurred was measured. Thirty three children, 38-61 months, were studied. None responded to the alarm with avoidance behavior but 18 looked toward the vehicle or hesitated in their gait. Although over half of the children acknowledged the warning alarm, the device did not elicit avoidance behavior. Mere acknowledgment of the warning device would not prevent injury.
Wu, Chueh-Yu; Lu, Jau-Ching; Liu, Man-Chi; Tung, Yi-Chung
2012-10-21
Microfluidic technology plays an essential role in various lab on a chip devices due to its desired advantages. An automated microfluidic system integrated with actuators and sensors can further achieve better controllability. A number of microfluidic actuation schemes have been well developed. In contrast, most of the existing sensing methods still heavily rely on optical observations and external transducers, which have drawbacks including: costly instrumentation, professional operation, tedious interfacing, and difficulties of scaling up and further signal processing. This paper reports the concept of electrofluidic circuits - electrical circuits which are constructed using ionic liquid (IL)-filled fluidic channels. The developed electrofluidic circuits can be fabricated using a well-developed multi-layer soft lithography (MSL) process with polydimethylsiloxane (PDMS) microfluidic channels. Electrofluidic circuits allow seamless integration of pressure sensors with analog and digital operation functions into microfluidic systems and provide electrical readouts for further signal processing. In the experiments, the analog operation device is constructed based on electrofluidic Wheatstone bridge circuits with electrical outputs of the addition and subtraction results of the applied pressures. The digital operation (AND, OR, and XOR) devices are constructed using the electrofluidic pressure controlled switches, and output electrical signals of digital operations of the applied pressures. The experimental results demonstrate the designed functions for analog and digital operations of applied pressures are successfully achieved using the developed electrofluidic circuits, making them promising to develop integrated microfluidic systems with capabilities of precise pressure monitoring and further feedback control for advanced lab on a chip applications.
Spatially Fourier-encoded photoacoustic microscopy using a digital micromirror device.
Liang, Jinyang; Gao, Liang; Li, Chiye; Wang, Lihong V
2014-02-01
We have developed spatially Fourier-encoded photoacoustic (PA) microscopy using a digital micromirror device. The spatial intensity distribution of laser pulses is Fourier-encoded, and a series of such encoded PA measurements allows one to decode the spatial distribution of optical absorption. The throughput and Fellgett advantages were demonstrated by imaging a chromium target. By using 63 spatial elements, the signal-to-noise ratio in the recovered PA signal was enhanced by ∼4×. The system was used to image two biological targets, a monolayer of red blood cells and melanoma cells.
Smith, Zachary J; Strombom, Sven; Wachsmann-Hogiu, Sebastian
2011-08-29
A multivariate optical computer has been constructed consisting of a spectrograph, digital micromirror device, and photomultiplier tube that is capable of determining absolute concentrations of individual components of a multivariate spectral model. We present experimental results on ternary mixtures, showing accurate quantification of chemical concentrations based on integrated intensities of fluorescence and Raman spectra measured with a single point detector. We additionally show in simulation that point measurements based on principal component spectra retain the ability to classify cancerous from noncancerous T cells.
Spatially Fourier-encoded photoacoustic microscopy using a digital micromirror device
Liang, Jinyang; Gao, Liang; Li, Chiye; Wang, Lihong V.
2014-01-01
We have developed spatially Fourier-encoded photoacoustic microscopy using a digital micromirror device. The spatial intensity distribution of laser pulses is Fourier-encoded, and a series of such encoded photoacoustic measurements allows one to decode the spatial distribution of optical absorption. The throughput and Fellgett advantages were demonstrated by imaging a chromium target. By using 63 spatial elements, the signal-to-noise ratio in the recovered photoacoustic signal was enhanced by ~4×. The system was used to image two biological targets, a monolayer of red blood cells and melanoma cells. PMID:24487832
Coherence measurement with digital micromirror device.
Partanen, Henri; Turunen, Jari; Tervo, Jani
2014-02-15
We measure the complex-valued spatial coherence function of a multimode broad-area laser diode using Young's classical double slit experiment realized with a digital micromirror device. We use this data to construct the coherent modes of the beam and to simulate its propagation before and after the measurement plane. When comparing the results to directly measured intensity profiles, we find excellent correspondence to the extent that even small details of the beam can be predicted. We also consider the number of measurement points required to model the beam with sufficient accuracy.
A prototype of a portable TDCR system at ENEA.
Capogni, Marco; De Felice, Pierino
2014-11-01
A prototype of a portable liquid scintillation counting system based on the Triple-to-Double Coincidence Ratio (TDCR) technique was developed at ENEA-INMRI in the framework of the European Metrofission project. The new device equipped with the CAEN digitizers was tested for the activity measurements of pure β-emitters ((99)Tc and (63)Ni). The list-mode data recorded by the digitizers were analyzed by software implemented in the CERN ROOT environment, which allows the application of pulse shape discrimination using the new device. Copyright © 2014 Elsevier Ltd. All rights reserved.
Chen, Xiaodong; Ren, Liqiang; Zheng, Bin; Liu, Hong
2013-01-01
The conventional optical microscopes have been used widely in scientific research and in clinical practice. The modern digital microscopic devices combine the power of optical imaging and computerized analysis, archiving and communication techniques. It has a great potential in pathological examinations for improving the efficiency and accuracy of clinical diagnosis. This chapter reviews the basic optical principles of conventional microscopes, fluorescence microscopes and electron microscopes. The recent developments and future clinical applications of advanced digital microscopic imaging methods and computer assisted diagnosis schemes are also discussed.
Vawter, G. Allen
2013-11-12
An optical XOR gate is formed as a photonic integrated circuit (PIC) from two sets of optical waveguide devices on a substrate, with each set of the optical waveguide devices including an electroabsorption modulator electrically connected in series with a waveguide photodetector. The optical XOR gate utilizes two digital optical inputs to generate an XOR function digital optical output. The optical XOR gate can be formed from III-V compound semiconductor layers which are epitaxially deposited on a III-V compound semiconductor substrate, and operates at a wavelength in the range of 0.8-2.0 .mu.m.
Skogen, Erik J [Albuquerque, NM; Tauke-Pedretti, Anna [Albuquerque, NM
2011-09-06
An optical NOR gate is formed from two pair of optical waveguide devices on a substrate, with each pair of the optical waveguide devices consisting of an electroabsorption modulator electrically connected in series with a waveguide photodetector. The optical NOR gate utilizes two digital optical inputs and a continuous light input to provide a NOR function digital optical output. The optical NOR gate can be formed from III-V compound semiconductor layers which are epitaxially deposited on a III-V compound semiconductor substrate, and operates at a wavelength in the range of 0.8-2.0 .mu.m.
Computer Graphics Instruction in VizClass
ERIC Educational Resources Information Center
Grimes, Douglas; Warschauer, Mark; Hutchinson, Tara; Kuester, Falko
2005-01-01
"VizClass" is a university classroom environment designed to offer students in computer graphics and engineering courses up-to-date visualization technologies. Three digital whiteboards and a three-dimensional stereoscopic display provide complementary display surfaces. Input devices include touchscreens on the digital whiteboards, remote…
Automatic Exposure Control Device for Digital Mammography
2001-08-01
developing innovative approaches for controlling DM exposures. These approaches entail using the digital detector and an artificial neural network to...of interest that determine the exposure parameters for the fully exposed image; and (2) to use an artificial neural network to select exposure
Automatic Exposure Control Device for Digital Mammography
2004-08-01
developing innovative approaches for controlling DM exposures. These approaches entail using the digital detector and an artificial neural network to...of interest that determine the exposure parameters for the fully exposed image; and (2) to use an artificial neural network to select exposure
Code of Federal Regulations, 2010 CFR
2010-07-01
....20 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio Recording... manufacture and distribution in the United States, of digital audio recording devices and media pursuant to 17...
Code of Federal Regulations, 2012 CFR
2012-07-01
....20 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio Recording... manufacture and distribution in the United States, of digital audio recording devices and media pursuant to 17...
Code of Federal Regulations, 2013 CFR
2013-07-01
....20 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio Recording... manufacture and distribution in the United States, of digital audio recording devices and media pursuant to 17...
Code of Federal Regulations, 2014 CFR
2014-07-01
....20 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio Recording... manufacture and distribution in the United States, of digital audio recording devices and media pursuant to 17...
Code of Federal Regulations, 2011 CFR
2011-07-01
....20 Patents, Trademarks, and Copyrights COPYRIGHT ROYALTY BOARD, LIBRARY OF CONGRESS SUBMISSION OF ROYALTY CLAIMS FILING OF CLAIMS TO ROYALTY FEES COLLECTED UNDER COMPULSORY LICENSE Digital Audio Recording... manufacture and distribution in the United States, of digital audio recording devices and media pursuant to 17...
Zulkepli, Siti Noor Idora Syafinaz; Hamid, Nor Hisham; Shukla, Vineeta
2018-05-08
In recent years, the number of interdisciplinary research works related to the development of miniaturized systems with integrated chemical and biological analyses is increasing. Digital microfluidic biochips (DMFBs) are one kind of miniaturized systems designed for conducting inexpensive, fast, convenient and reliable biochemical assay procedures focusing on basic scientific research and medical diagnostics. The role of a dielectric layer in the digital microfluidic biochips is prominent as it helps in actuating microliter droplets based on the electrowetting-on-dielectric (EWOD) technique. The advantages of using three different material layers of dielectric such as parafilm, polytetrafluoroethylene (PTFE) and ethylene tetrafluoroethylene (ETFE) were reported in the current work. A simple fabrication process of a digital microfluidic device was performed and good results were obtained. The threshold of the actuation voltage was determined for all dielectric materials of varying thicknesses. Additionally, the OpenDrop device was tested by utilizing a single-plate system to transport microliter droplets for a bioassay operation. With the newly proposed fabrication methods, these dielectric materials showed changes in contact angle and droplet velocity when the actuation voltage was applied. The threshold actuation voltage for the dielectric layers of 10⁻13 μm was 190 V for the open plate DMFBs.
Measurement-device-independent quantum digital signatures
NASA Astrophysics Data System (ADS)
Puthoor, Ittoop Vergheese; Amiri, Ryan; Wallden, Petros; Curty, Marcos; Andersson, Erika
2016-08-01
Digital signatures play an important role in software distribution, modern communication, and financial transactions, where it is important to detect forgery and tampering. Signatures are a cryptographic technique for validating the authenticity and integrity of messages, software, or digital documents. The security of currently used classical schemes relies on computational assumptions. Quantum digital signatures (QDS), on the other hand, provide information-theoretic security based on the laws of quantum physics. Recent work on QDS Amiri et al., Phys. Rev. A 93, 032325 (2016);, 10.1103/PhysRevA.93.032325 Yin, Fu, and Zeng-Bing, Phys. Rev. A 93, 032316 (2016), 10.1103/PhysRevA.93.032316 shows that such schemes do not require trusted quantum channels and are unconditionally secure against general coherent attacks. However, in practical QDS, just as in quantum key distribution (QKD), the detectors can be subjected to side-channel attacks, which can make the actual implementations insecure. Motivated by the idea of measurement-device-independent quantum key distribution (MDI-QKD), we present a measurement-device-independent QDS (MDI-QDS) scheme, which is secure against all detector side-channel attacks. Based on the rapid development of practical MDI-QKD, our MDI-QDS protocol could also be experimentally implemented, since it requires a similar experimental setup.