Sample records for digital electronic stethoscope

  1. Integrating a Hand Held computer and Stethoscope into a Fetal Monitor

    PubMed Central

    Ahmad Soltani, Mitra

    2009-01-01

    This article presents procedures for modifying a hand held computer or personal digital assistant (PDA) into a versatile device functioning as an electronic stethoscope for fetal monitoring. Along with functioning as an electronic stethoscope, a PDA can provide a useful information source for a medical trainee. Feedback from medical students, residents and interns suggests the device is well accepted by medical trainees. PMID:20165517

  2. Comparison of conventional and sensor-based electronic stethoscopes in detecting cardiac murmurs of dogs.

    PubMed

    Vörös, K; Bonnevie, A; Reiczigel, J

    2012-04-24

    Cardiac auscultation is one of the most important parts of the cardiological examination traditionally performed with acoustic stethoscopes. The aim of this study was to compare the sensitivities and the diagnostic capabilities of traditional and electronic stethoscopes in detecting canine heart murmurs. The study was performed on 21 dogs referred for cardiologic examination with suspected heart murmurs. Six out of these dogs had cardiac murmurs bilaterally. Cardiac auscultation was performed independently by a final-year veterinary student (AB=I1) and by an experienced clinician (KV=I2), both using a traditional and a Welch Allyn Meditron electronic sensor-based stethoscope. Final diagnoses were established by echocardiography and by digital phonocardiography. Correct detection of a murmur was made by I1 with a traditional stethoscope in 20/27 (74.0%) of the suspected murmurs (p=0.30, kappa[κ] =0.2) and with the electronic stethoscope in 26/27 (96.3%), respectively (p=0.0013, κ=0.75). I2 correctly detected the murmurs with the traditional stethoscope in 25/27 (92.6%) cases (p=0.0013, κ=0.75) and with the electronic stethoscope in all 27/27 (100%) cases (p=0.00012, κ=1). Agreements of murmur intensity gradings between traditional and electronic stethoscopes were highly significant (I1: p=6.9´10⁻⁸; κ=0.79), (I2: p=5.2´10⁻¹¹; κ=0.92). When grading the murmurs with the traditional stethoscope, there was a significant agreement between I1 and I2 (p=2.9´10⁻⁷; κ=0.79), being even higher with the electronic stethoscope (p=1.1´10⁻¹¹; κ=0.92). The electronic stethoscope was more sensitive than the traditional one in detecting and grading cardiac murmurs being especially useful for I1 with less experience. However, it can be suggested to use a traditional and an electronic stethoscopes simultaneously to optimally utilize their advantages.

  3. Digital stethoscopes compared to standard auscultation for detecting abnormal paediatric breath sounds.

    PubMed

    Kevat, Ajay C; Kalirajah, Anaath; Roseby, Robert

    2017-07-01

    Our study aimed to objectively describe the audiological characteristics of wheeze and crackles in children by using digital stethoscope (DS) auscultation, as well as assess concordance between standard auscultation and two different DS devices in their ability to detect pathological breath sounds. Twenty children were auscultated by a paediatric consultant doctor and digitally recorded using the Littman™ 3200 Digital Electronic Stethoscope and a Clinicloud™ DS with smart device. Using spectrographic analysis, we found those with clinically described wheeze had prominent periodic waveform segments spanning expiration for a period of 0.03-1.2 s at frequencies of 100-1050 Hz, and occasionally spanning shorter inspiratory segments; paediatric crackles were brief discontinuous sounds with a distinguishing waveform. There was moderate concordance with respect to wheeze detection between digital and standard binaural stethoscopes, and 100% concordance for crackle detection. Importantly, DS devices were more sensitive than clinician auscultation in detecting wheeze in our study. Objective definition of audio characteristics of abnormal paediatric breath sounds was achieved using DS technology. We demonstrated superiority of our DS method compared to traditional auscultation for detection of wheeze. What is Known: • The audiological characteristics of abnormal breath sounds have been well-described in adult populations but not in children. • Inter-observer agreement for detection of pathological breath sounds using standard auscultation has been shown to be poor, but the clinical value of now easily available digital stethoscopes has not been sufficiently examined. What is New: • Digital stethoscopes can objectively define the nature of pathological breath sounds such as wheeze and crackles in children. • Paediatric wheeze was better detected by digital stethoscopes than by standard auscultation performed by an expert paediatric clinician.

  4. Comparison of Two Digital Stethoscopes with the Traditional Stethoscope Used on International Space Station

    NASA Technical Reports Server (NTRS)

    Rasbury, Jack; Bascal, Kira; Ownby, Matt; McCulley, Phyllis; Paul, Bonnie

    2004-01-01

    A traditional stethoscope is currently flown on the International Space Station (ISS). The background noise on the ISS is much higher than a normal exam room, and the literature shows that traditional stethoscopes are unable to function effectively in high noise environments. Digital stethoscopes provide amplification which improves the audibility in a quiet environment. This study is designed to determine if digital stethoscopes offer any advantage over traditional stethoscopes in being able to identify normal and abnormal sounds in the ISS noise environment. Methods: An ISS noise simulation facility was created to reproduce ISS noise profiles by modifying pink noise with a software-based graphic equalizer. The files were played in a continuous loop on a computer, amplified through a high-end stereo system and adjusted using a sound level meter. Nine caregiver analogues were given the same auscultation lesson received by astronauts. They began testing by becoming familiar with normal and abnormal sounds on a Student Auscultation Manikin . They then used two digital stethoscopes and a traditional stethoscope identical to the one flown on the ISS to auscultate the manikin sounds in the noise facility. They identified the sounds on a questionnaire and picked which of the three stethoscopes they preferred. Results: Evaluators displayed equivalent accuracy in sound identification when using either the 3M model 4000 digital stethoscope or traditional stethoscope. However, the 3M was preferred 2 to 1 by the evaluators, primarily because of additional amplification of the sounds. Discussion: Although our results show that the current ISS stethoscope and the "best-of-breed" digital stethoscope provide essentially the same auscultation utility, the latter has the advantage of recording and transmitting sounds to a remote physician. Since the astronaut caregivers are non-physiCians, this capability may be worth the additional expense and effort needed to certify the digital stethoscope for flight.

  5. Development of digital stethoscope for telemedicine.

    PubMed

    Lakhe, Aparna; Sodhi, Isha; Warrier, Jyothi; Sinha, Vineet

    2016-01-01

    The stethoscope is a medical acoustic device which is used to auscultate internal body sounds, mainly the heart and lungs. A digital stethoscope overcomes the limitations of a conventional stethoscope as the sound data is transformed into electrical signals which can be amplified, stored, replayed and, more importantly, sent for an expert opinion, making it very useful in telemedicine. With the above in view, a low cost digital stethoscope has been developed which is interfaceble with mobile communication devices. In this instrument sounds from various locations can be captured with the help of an electret condenser microphone. Captured sound is filtered, amplified and processed digitally using an adaptive line enhancement technique to obtain audible and distinct heart sounds.

  6. A low-cost 3-D printed stethoscope connected to a smartphone.

    PubMed

    Aguilera-Astudillo, Carlos; Chavez-Campos, Marx; Gonzalez-Suarez, Alan; Garcia-Cordero, Jose L

    2016-08-01

    We demonstrate the fabrication of a digital stethoscope using a 3D printer and commercial off-the-shelf electronics. A chestpiece consists of an electret microphone embedded into the drum of a 3D printed chestpiece. An electronic dongle amplifies the signal from the microphone and reduces any external noise. It also adjusts the signal to the voltages accepted by the smartphones headset jack. A graphical user interface programmed in Android displays the signals processed by the dongle. The application also saves the processed signal and sends it to a physician.

  7. Digital stethoscope as an innovative tool on the teaching of auscultatory skills.

    PubMed

    Mesquita, Claudio Tinoco; Reis, Jader Costa dos; Simões, Luciana Silveira; Moura, Eduardo Cardoso de; Rodrigues, Gustavo Amarante; Athayde, Carolina Cunto de; Machado, Hugo Lima; Lanzieri, Pedro Gemal

    2013-02-01

    Physical cardiovascular examination, particularly cardiac auscultation, is one of the most difficult clinical skills for students during their medical training. Studies suggest that the use of technologies such as digital stethoscope increase the accuracy of clinical examination, however, its impact on the teaching of cardiac auscultation for undergraduate students of medicine is not known. The objective is to demonstrate the usefulness of the digital stethoscope compared to traditional methods as a tool in the teaching of auscultatory skills. nterventional, longitudinal, controlled, unicenter and randomized study. Thirty-eight medicine students were enrolled for a cardiovascular semiology course lasting eight weeks. The course program included lectures and bedside practice in Cardiology wards. In the practical lessons, the students were randomized into two groups: 1) (n = 21) digital stethoscope (Littmann® Model 3200, 3M); and 2) (n = 17) conventional stethoscopes. A pre-training evaluation was conducted through a test using the software Heart Sounds®, which was repeated after the course. The average scores were compared by paired T test and unpaired T test. It is observed that, at the end of the course, there was a significantly greater improvement in the group that used the digital stethoscope (51.9%) compared to the group using the conventional stethoscope (29.5%). Short-term interventions for cardiac semiology teaching are able to contribute significantly to improving proficiency in the identification of heart sounds. The use of digital stethoscope proved to be a positive factor in teaching these skills.

  8. Digital stethoscope system: the feasibility of cardiac auscultation

    NASA Astrophysics Data System (ADS)

    Pariaszewska, Katarzyna; Młyńczak, Marcel; Niewiadomski, Wiktor; Cybulski, Gerard

    2013-10-01

    The application of the digital stethoscope system is a new tendency in methods of cardiac auscultation. Heart sounds, generated by the fluctuations of blood velocity and vibrations of muscle structure, are an important signal in the primary diagnosis of heart diseases. Since the XIXs century for physical examination an analog stethoscope was used, but the development of microelectronics enable the construction of digital stethoscopes which started modern phonocardiography. The typical hardware of the system could be divided into analog and digital parts, respectively. The first one consists of microphone and pre-amplifier. The second one contains a microcontroller with peripherals for data saving and transmission. Usually the specialized software is applied for the signal acquisition and digital signal processing (filtering, spectral analysis and others). This paper presents an overview of methods used in cardiac auscultation and expected developing path in the future. It also contains the description of our digital stethoscope system, which is planned to be used in poliphysiographical studies.

  9. Prototype electronic stethoscope vs. conventional stethoscope for auscultation of heart sounds.

    PubMed

    Kelmenson, Daniel A; Heath, Janae K; Ball, Stephanie A; Kaafarani, Haytham M A; Baker, Elisabeth M; Yeh, Daniel D; Bittner, Edward A; Eikermann, Matthias; Lee, Jarone

    2014-08-01

    In an effort to decrease the spread of hospital-acquired infections, many hospitals currently use disposable plastic stethoscopes in patient rooms. As an alternative, this study examines a prototype electronic stethoscope that does not break the isolation barrier between clinician and patient and may also improve the diagnostic accuracy of the stethoscope exam. This study aimed to investigate whether the new prototype electronic stethoscope improved auscultation of heart sounds compared to the standard conventional isolation stethoscope. In a controlled, non-blinded, cross-over study, clinicians were randomized to identify heart sounds with both the prototype electronic stethoscope and a conventional stethoscope. The primary outcome was the score on a 10-question heart sound identification test. In total, 41 clinicians completed the study. Subjects performed significantly better in the identification of heart sounds when using the prototype electronic stethoscope (median = 9 [7-10] vs. 8 [6-9] points, p value <0.0001). Subjects also significantly preferred the prototype electronic stethoscope. Clinicians using a new prototype electronic stethoscope achieved greater accuracy in identification of heart sounds and also universally favoured the new device, compared to the conventional stethoscope.

  10. Digital stethoscope: technology update.

    PubMed

    Swarup, Supreeya; Makaryus, Amgad N

    2018-01-01

    Cardiovascular disease (CVD) is recognized as the leading cause of mortality throughout the world. About one-third of global mortality is attributable to CVD. In addition to clinical presentation, specific clinical exam findings can assist in treating and preventing CVD. CVD may initially manifest as pulmonary pathology, and thus, accurate cardiopulmonary auscultation is paramount to establishing accurate diagnosis. One of the most powerful tools available to physicians is the stethoscope. The stethoscope first emerged in the year 1818, invented by a French physician, René Laennec. Since then, the initial modest monaural wooden tube has evolved into a sophisticated digital device. This paper provides an analysis of the evolution of the stethoscope as well as highlights the advancement made by the modern digital stethoscope including the application of this tool in advancing care for patients suffering from CVD.

  11. Digital stethoscope: technology update

    PubMed Central

    Swarup, Supreeya; Makaryus, Amgad N

    2018-01-01

    Cardiovascular disease (CVD) is recognized as the leading cause of mortality throughout the world. About one-third of global mortality is attributable to CVD. In addition to clinical presentation, specific clinical exam findings can assist in treating and preventing CVD. CVD may initially manifest as pulmonary pathology, and thus, accurate cardiopulmonary auscultation is paramount to establishing accurate diagnosis. One of the most powerful tools available to physicians is the stethoscope. The stethoscope first emerged in the year 1818, invented by a French physician, René Laennec. Since then, the initial modest monaural wooden tube has evolved into a sophisticated digital device. This paper provides an analysis of the evolution of the stethoscope as well as highlights the advancement made by the modern digital stethoscope including the application of this tool in advancing care for patients suffering from CVD. PMID:29379321

  12. Direct Signal-to-Noise Quality Comparison between an Electronic and Conventional Stethoscope aboard the International Space Station

    NASA Technical Reports Server (NTRS)

    Marshburn, Thomas; Cole, Richard; Ebert, Doug; Bauer, Pete

    2014-01-01

    Introduction: Evaluation of heart, lung, and bowel sounds is routinely performed with the use of a stethoscope to help detect a broad range of medical conditions. Stethoscope acquired information is even more valuable in a resource limited environments such as the International Space Station (ISS) where additional testing is not available. The high ambient noise level aboard the ISS poses a specific challenge to auscultation by stethoscope. An electronic stethoscope's ambient noise-reduction, greater sound amplification, recording capabilities, and sound visualization software may be an advantage to a conventional stethoscope in this environment. Methods: A single operator rated signal-to-noise quality from a conventional stethoscope (Littman 2218BE) and an electronic stethoscope (Litmann 3200). Borborygmi, pulmonic, and cardiac sound quality was ranked with both stethoscopes. Signal-to-noise rankings were preformed on a 1 to 10 subjective scale with 1 being inaudible, 6 the expected quality in an emergency department, 8 the expected quality in a clinic, and 10 the clearest possible quality. Testing took place in the Japanese Pressurized Module (JPM), Unity (Node 2), Destiny (US Lab), Tranquility (Node 3), and the Cupola of the International Space Station. All examinations were conducted at a single point in time. Results: The electronic stethoscope's performance ranked higher than the conventional stethoscope for each body sound in all modules tested. The electronic stethoscope's sound quality was rated between 7 and 10 in all modules tested. In comparison, the traditional stethoscope's sound quality was rated between 4 and 7. The signal to noise ratio of borborygmi showed the biggest difference between stethoscopes. In the modules tested, the auscultation of borborygmi was rated between 5 and 7 by the conventional stethoscope and consistently 10 by the electronic stethoscope. Discussion: This stethoscope comparison was limited to a single operator. However, we believe the results are noteworthy. The electronic stethoscope out preformed the traditional stethoscope in each direct comparison. Consideration should be made to incorporate an electronic stethoscope into current and future space vehicle medical kits.

  13. Clinical evaluation of the 3M Littmann Electronic Stethoscope Model 3200 in 150 cats.

    PubMed

    Blass, Keith A; Schober, Karsten E; Bonagura, John D; Scansen, Brian A; Visser, Lance C; Lu, Jennifer; Smith, Danielle N; Ward, Jessica L

    2013-10-01

    Detection of murmurs and gallops may help to identify cats with heart disease. However, auscultatory findings may be subject to clinically relevant observer variation. The objective of this study was to evaluate an electronic stethoscope (ES) in cats. We hypothesized that the ES would perform at least as well as a conventional stethoscope (CS) in the detection of abnormal heart sounds. One hundred and fifty consecutive cats undergoing echocardiography were enrolled prospectively. Cats were ausculted with a CS (WA Tycos Harvey Elite) by two observers, and heart sounds were recorded digitally using an ES (3M Littmann Stethoscope Model 3200) for off-line analysis. Echocardiography was used as the clinical standard method for validation of auscultatory findings. Additionally, digital recordings (DRs) were assessed by eight independent observers with various levels of expertise, and compared using interclass correlation and Cohen's weighted kappa analyses. Using the CS, a heart murmur (n = 88 cats) or gallop sound (n = 17) was identified in 105 cats, whereas 45 cats lacked abnormal heart sounds. There was good total agreement (83-90%) between the two observers using the CS. In contrast, there was only moderate agreement (P <0.001) between results from the CS and the DRs for murmurs, and poor agreement for gallops. The CS was more sensitive compared with the DRs with regard to murmurs and gallops. Agreement among the eight observers was good-to-excellent for murmur detection (81%). In conclusion, DRs made with the ES are less sensitive but comparably specific to a CS at detecting abnormal heart sounds in cats.

  14. The stethoscope - A 200th anniversary.

    PubMed

    Permin, Henrik; Norn, Svend

    René T.H. Laënnec was the man who designed the first monaural instrument for mediate auscultation. The invention became a medical breakthrough. An instrument capable of enhancing the subtle sounds created by the human heart and lungs. This evolutionary instrument also had the benefit of decreasing the oftentim s too direct bodily contact between the doctor and the patient. Laënnec carefully described the different sounds created by the human organs and attempted to link them to the post mortem findings. Even though many doctors were enthusiastic regarding this new medical breakthrough, the stethoscope also had its opponents, but John Forbes' English translation of Laënnec's De l'auscultation midiate as well as William Stokes' treatise on the use of the stethoscope spread the news to the medical world. In Denmark the stethoscope was introduced by Oluf Lundt Bang, S.M. Trier and E. Hornemann. The next step forward was the develop- ment of the binaural stethoscope by G.P. Camman in New York. The Littmann Electronic Stethoscope (3M Health Care) created by David Littmann is considered the leading product globally in this medical field. Digitization, ultrasound and Doppler effect, as well as 2D and 3D printing, are evidence of an on-going evolution within this field of medical equipment as we get ready to celebrate the stethoscopes 200th anniversary.

  15. Determination of heart rate variability with an electronic stethoscope.

    PubMed

    Kamran, Haroon; Naggar, Isaac; Oniyuke, Francisca; Palomeque, Mercy; Chokshi, Priya; Salciccioli, Louis; Stewart, Mark; Lazar, Jason M

    2013-02-01

    Heart rate variability (HRV) is widely used to characterize cardiac autonomic function by measuring beat-to-beat alterations in heart rate. Decreased HRV has been found predictive of worse cardiovascular (CV) outcomes. HRV is determined from time intervals between QRS complexes recorded by electrocardiography (ECG) for several minutes to 24 h. Although cardiac auscultation with a stethoscope is performed routinely on patients, the human ear cannot detect heart sound time intervals. The electronic stethoscope digitally processes heart sounds, from which cardiac time intervals can be obtained. Accordingly, the objective of this study was to determine the feasibility of obtaining HRV from electronically recorded heart sounds. We prospectively studied 50 subjects with and without CV risk factors/disease and simultaneously recorded single lead ECG and heart sounds for 2 min. Time and frequency measures of HRV were calculated from R-R and S1-S1 intervals and were compared using intra-class correlation coefficients (ICC). The majority of the indices were strongly correlated (ICC 0.73-1.0), while the remaining indices were moderately correlated (ICC 0.56-0.63). In conclusion, we found HRV measures determined from S1-S1 are in agreement with those determined by single lead ECG, and we demonstrate and discuss differences in the measures in detail. In addition to characterizing cardiac murmurs and time intervals, the electronic stethoscope holds promise as a convenient low-cost tool to determine HRV in the hospital and outpatient settings as a practical extension of the physical examination.

  16. Comparison of traditional and sensor-based electronic stethoscopes in beagle dogs.

    PubMed

    Szilvási, Viktória; Vörös, Károly; Manczur, Ferenc; Reiczigel, Jenő; Novák, István; Máthé, Akos; Fekete, Dániel

    2013-03-01

    The objective of this study was to compare the auscultatory findings using traditional and electronic sensor-based stethoscopes. Thirty-three adult healthy Beagles (20 females, 13 males, mean age: 4.8 years, range 1.4-8 years) were auscultated by four investigators with different experiences (INVEST-1, -2, -3 and -4) independently with both stethoscopes. Final cardiological diagnoses were established by echocardiography. Mitral murmurs were heard with both stethoscopes by all investigators and echocardiography revealed mild mitral valve insufficiency in 7 dogs (21%, 4 females, 3 males). The statistical sensitivity (Se) in recognising cardiac murmurs proved to be 82% using the traditional stethoscope and 75% using the electronic one in the mean of the four examiners, whilst statistical specificity (Sp) was 99% by the traditional and 100% by the electronic stethoscope. The means of the auscultatory sensitivity differences between the two stethoscopes were 0.36 on the left and 0.59 on the right hemithorax, demonstrating an advantage for the electronic stethoscope being more obvious above the right hemithorax (P = 0.0340). The electronic stethoscope proved to be superior to the traditional one in excluding cardiac murmurs and especially in auscultation over the right hemithorax. Mitral valve disease was relatively common in this clinically healthy research Beagle population.

  17. Auscultation in flight: comparison of conventional and electronic stethoscopes.

    PubMed

    Tourtier, J P; Libert, N; Clapson, P; Tazarourte, K; Borne, M; Grasser, L; Debien, B; Auroy, Y

    2011-01-01

    The ability to auscultate during air medical transport is compromised by high ambient-noise levels. The aim of this study was to assess the capabilities of a traditional and an electronic stethoscope (which is expected to amplify sounds and reduce ambient noise) to assess heart and breath sounds during medical transport in a Boeing C135. We tested one model of a traditional stethoscope (3MTM Littmann Cardiology IIITM) and one model of an electronic stethoscope (3MTM Littmann Stethoscope Model 3000). We studied heart and lung auscultation during real medical evacuations aboard a medically configured C135. For each device, the quality of auscultation was described using a visual rating scale (ranging from 0 to 100 mm, 0 corresponding to "I hear nothing," 100 to "I hear perfectly"). Comparisons were accomplished using a t-test for paired values. A total of 36 comparative evaluations were performed. For cardiac auscultation, the value of the visual rating scale was 53 ± 24 and 85 ± 11 mm, respectively, for the traditional and electronic stethoscope (paired t-test: P = .0024). For lung sounds, quality of auscultation was estimated at 27 ± 17 mm for traditional stethoscope and 68 ± 13 for electronic stethoscope (paired t-test: P = .0003). The electronic stethoscope was considered to be better than the standard model for hearing heart and lung sounds. Flight practitioners involved in air medical evacuation in the C135 aircraft are better able to practice auscultation with this electronic stethoscope than with a traditional one. Copyright © 2011 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.

  18. Brief report: pulmonary auscultation in the operating room: a prospective randomized blinded trial comparing electronic and conventional stethoscopes.

    PubMed

    Hoffmann, Clement; Falzone, Elisabeth; Verret, Catherine; Pasquier, Pierre; Leclerc, Thomas; Donat, Nicolas; Jost, Daniel; Mérat, Stephane; Maurice, Guillaume de Saint; Lenoir, Bernard; Auroy, Yves; Tourtier, Jean-Pierre

    2013-09-01

    We compared the subjective quality of pulmonary auscultation between 2 acoustic stethoscopes (Holtex Ideal® and Littmann Cardiology III®) and an electronic stethoscope (Littmann 3200®) in the operating room. A prospective double-blind randomized study with an evaluation during mechanical ventilation was performed in 100 patients. After each examination, the listeners using a numeric scale (0-10) rated the quality of auscultation. Auscultation quality was compared in patients among stethoscopes with a multilevel mixed-effects linear regression with random intercept (operator effect), adjusted on significant factors in univariate analysis. A significant difference was defined as P < 0.05. One hundred comparative evaluations of pulmonary auscultation were performed. The quality of auscultation was rated 8.2 ± 1.6 for the electronic stethoscope, 7.4 ± 1.8 for the Littmann Cardiology III, and 4.6 ± 1.8 for the Holtex Ideal. Compared with Holtex Ideal, auscultation quality was significantly higher with other stethoscopes (P < 0.0001). Compared with Littmann Cardiology III, auscultation quality was significantly higher with Littmann 3200 electronic stethoscope (β = 0.9 [95% confidence interval, 0.5-1.3]). An electronic stethoscope can provide a better quality of pulmonary auscultation than acoustic stethoscopes in the operating room, yet with a magnitude of improvement marginally higher than that provided with a high performance acoustic stethoscope. Whether this can translate into a clinically relevant benefit requires further studies.

  19. A simulator-based study of in-flight auscultation.

    PubMed

    Tourtier, Jean-Pierre; Libert, Nicolas; Clapson, Patrick; Dubourdieu, Stéphane; Jost, Daniel; Tazarourte, Karim; Astaud, Cécil-Emmanuel; Debien, Bruno; Auroy, Yves

    2014-04-01

    The use of a stethoscope is essential to the delivery of continuous, supportive en route care during aeromedical evacuations. We compared the capability of 2 stethoscopes (electronic, Litmann 3000; conventional, Litmann Cardiology III) at detecting pathologic heart and lung sounds, aboard a C135, a medical transport aircraft. Sounds were mimicked using a mannequin-based simulator SimMan. Five practitioners examined the mannequin during a fly, with a variety of abnormalities as follows: crackles, wheezing, right and left lung silence, as well as systolic, diastolic, and Austin-Flint murmur. The comparison for diagnosis assessed (correct or wrong) between using the electronic and conventional stethoscopes were performed as a McNemar test. A total of 70 evaluations were performed. For cardiac sounds, diagnosis was right in 0/15 and 4/15 auscultations, respectively, with conventional and electronic stethoscopes (McNemar test, P = 0.13). For lung sounds, right diagnosis was found with conventional stethoscope in 10/20 auscultations versus 18/20 with electronic stethoscope (P = 0.013). Flight practitioners involved in aeromedical evacuation on C135 plane are more able to practice lung auscultation on a mannequin with this amplified stethoscope than with the traditional one. No benefit was found for heart sounds.

  20. Acoustics based assessment of respiratory diseases using GMM classification.

    PubMed

    Mayorga, P; Druzgalski, C; Morelos, R L; Gonzalez, O H; Vidales, J

    2010-01-01

    The focus of this paper is to present a method utilizing lung sounds for a quantitative assessment of patient health as it relates to respiratory disorders. In order to accomplish this, applicable traditional techniques within the speech processing domain were utilized to evaluate lung sounds obtained with a digital stethoscope. Traditional methods utilized in the evaluation of asthma involve auscultation and spirometry, but utilization of more sensitive electronic stethoscopes, which are currently available, and application of quantitative signal analysis methods offer opportunities of improved diagnosis. In particular we propose an acoustic evaluation methodology based on the Gaussian Mixed Models (GMM) which should assist in broader analysis, identification, and diagnosis of asthma based on the frequency domain analysis of wheezing and crackles.

  1. The electronic stethoscope.

    PubMed

    Leng, Shuang; Tan, Ru San; Chai, Kevin Tshun Chuan; Wang, Chao; Ghista, Dhanjoo; Zhong, Liang

    2015-07-10

    Most heart diseases are associated with and reflected by the sounds that the heart produces. Heart auscultation, defined as listening to the heart sound, has been a very important method for the early diagnosis of cardiac dysfunction. Traditional auscultation requires substantial clinical experience and good listening skills. The emergence of the electronic stethoscope has paved the way for a new field of computer-aided auscultation. This article provides an in-depth study of (1) the electronic stethoscope technology, and (2) the methodology for diagnosis of cardiac disorders based on computer-aided auscultation. The paper is based on a comprehensive review of (1) literature articles, (2) market (state-of-the-art) products, and (3) smartphone stethoscope apps. It covers in depth every key component of the computer-aided system with electronic stethoscope, from sensor design, front-end circuitry, denoising algorithm, heart sound segmentation, to the final machine learning techniques. Our intent is to provide an informative and illustrative presentation of the electronic stethoscope, which is valuable and beneficial to academics, researchers and engineers in the technical field, as well as to medical professionals to facilitate its use clinically. The paper provides the technological and medical basis for the development and commercialization of a real-time integrated heart sound detection, acquisition and quantification system.

  2. Feasibility of an electronic stethoscope system for monitoring neonatal bowel sounds.

    PubMed

    Dumas, Jasmine; Hill, Krista M; Adrezin, Ronald S; Alba, Jorge; Curry, Raquel; Campagna, Eric; Fernandes, Cecilia; Lamba, Vineet; Eisenfeld, Leonard

    2013-09-01

    Bowel dysfunction remains a major problem in neonates. Traditional auscultation of bowel sounds as a diagnostic aid in neonatal gastrointestinal complications is limited by skill and inability to document and reassess. Consequently, we built a unique prototype to investigate the feasibility of an electronic monitoring system for continuous assessment of bowel sounds. We attained approval by the Institutional Review Boards for the investigational study to test our system. The system incorporated a prototype stethoscope head with a built-in microphone connected to a digital recorder. Recordings made over extended periods were evaluated for quality. We also considered the acoustic environment of the hospital, where the stethoscope was used. The stethoscope head was attached to the abdomen with a hydrogel patch designed especially for this purpose. We used the system to obtain recordings from eight healthy, full-term babies. A scoring system was used to determine loudness, clarity, and ease of recognition comparing it to the traditional stethoscope. The recording duration was initially two hours and was increased to a maximum of eight hours. Median duration of attachment was three hours (3.75, 2.68). Based on the scoring, the bowel sound recording was perceived to be as loud and clear in sound reproduction as a traditional stethoscope. We determined that room noise and other noises were significant forms of interference in the recordings, which at times prevented analysis. However, no sound quality drift was noted in the recordings and no patient discomfort was noted. Minimal erythema was observed over the fixation site which subsided within one hour. We demonstrated the long-term recording of infant bowel sounds. Our contributions included a prototype stethoscope head, which was affixed using a specially designed hydrogel adhesive patch. Such a recording can be reviewed and reassessed, which is new technology and an improvement over current practice. The use of this system should also, theoretically, reduce risk of infection. Based on our research we concluded that while automatic assessment of bowel sounds is feasible over an extended period, there will be times when analysis is not possible. One limitation is noise interference. Our larger goals include producing a meaningful vital sign to characterize bowel sounds that can be produced in real-time, as well as providing automatic control for patient feeding pumps.

  3. Cardiac auscultation training of medical students: a comparison of electronic sensor-based and acoustic stethoscopes

    PubMed Central

    Høyte, Henning; Jensen, Torstein; Gjesdal, Knut

    2005-01-01

    Background To determine whether the use of an electronic, sensor based stethoscope affects the cardiac auscultation skills of undergraduate medical students. Methods Forty eight third year medical students were randomized to use either an electronic stethoscope, or a conventional acoustic stethoscope during clinical auscultation training. After a training period of four months, cardiac auscultation skills were evaluated using four patients with different cardiac murmurs. Two experienced cardiologists determined correct answers. The students completed a questionnaire for each patient. The thirteen questions were weighted according to their relative importance, and a correct answer was credited from one to six points. Results No difference in mean score was found between the two groups (p = 0.65). Grading and characterisation of murmurs and, if present, report of non existing murmurs were also rated. None of these yielded any significant differences between the groups. Conclusion Whether an electronic or a conventional stethoscope was used during training and testing did not affect the students' performance on a cardiac auscultation test. PMID:15882458

  4. A comparative study of electronic stethoscopes for cardiac auscultation.

    PubMed

    Pinto, C; Pereira, D; Ferreira-Coimbra, J; Portugues, J; Gama, V; Coimbra, M

    2017-07-01

    There are several electronic stethoscopes available on the market today, with a very high potential for healthcare namely telemedicine, assisted decision and education. However, there are no recent comparatives studies published about the recording quality of auscultation sounds. In this study we aim to: a) define a ranking, according to experts opinion of 6 of the most relevant electronic stethoscopes on the market today; b) verify if there are any relations between a stethoscope's performance and the type of pathology present; c) analyze if some pathologies are more easily identified than others when using electronic auscultation. Our methodology consisted in creating two study groups: the first group included 18 cardiologists and cardiology house officers, acting as the gold standard of this work. The second included 30 medical students. Using a database of heart sounds recorded in real hospital environments, we applied questionnaires to observers from each group. The first group listened to 60 cardiac auscultations recorded by the 6 stethoscopes, and each one was asked to identify the pathological sound present: aortic stenosis, mitral regurgitation or normal. The second group was asked to choose, between two auscultation recordings, using as criteria the best sound quality for the identification of pathological sounds. Results include a total of 1080 evaluations, in which 72% of cases were correctly diagnosed. A detailed breakdown of these results is presented in this paper. As conclusions, results showed that the impact of the differences between stethoscopes is very small, given that we did not find statistically significant differences between all pairs of stethoscopes. Normal sounds showed to be easier to identify than pathological sounds, but we did not find differences between stethoscopes in this identification.

  5. Evaluation of Thoracic Injury in Swine Model with a Noise Immune Stethoscope

    DTIC Science & Technology

    2011-04-01

    USAARL Report No. 2011-16 Evaluation of Thoracic Injury in Swine Model with a Noise Immune Stethoscope By Alaistair Bushby Eric J. Ansorge Keith...Include area code) 22-04-2011 Final Evaluation of Thoracic Injury in Swine Model with a Noise Immune Stethoscope Alaistair Bushby Eric J. Ansorge...and to provide life saving interventions. This study evaluated the feasibility and sensitivity of a newly developed electronic stethoscope concept

  6. In-flight auscultation during medical air evacuation: comparison between traditional and amplified stethoscopes.

    PubMed

    Fontaine, Emmanuelle; Coste, Sébastien; Poyat, Chrystelle; Klein, Céline; Lefort, Hugues; Leclerc, Thomas; Dubourdieu, Stéphane; Briche, Frédérique; Jost, Daniel; Maurin, Olga; Domanski, Laurent; Tourtier, Jean-Pierre

    2014-01-01

    The aim of this study was to evaluate the capacity of a traditional stethoscope versus an electronically amplified one (expected to reduce background and ambient noise) to assess heart and respiratory sounds during medical transport. It was a prospective, double-blinded, randomized performed study. One traditional stethoscope (Littmann Cardiology III; 3M, St Paul, MN) and 1 electronically amplified stethoscope (Littmann 3200, 3M) were used for our tests. Heart and lung auscultation during real medical evacuations aboard a medically configured Falcon 50 aircrafts were studied. The quality of auscultation was ranged using a numeric rating scale from 0 to 10 (0 corresponding to "I hear nothing" and 10 to "I hear perfectly"). Data collected were compared using a t-test for paired values. A total of 40 comparative evaluations were performed. For cardiac auscultation, the value of the rating scale was 4.53 ± 1.91 and 7.18 ± 1.88 for the traditional and amplified stethoscope, respectively (paired t-test: P < .0001). For respiratory sounds, quality of auscultation was estimated at 3.1 ± 1.95 for a traditional stethoscope and 5.10 ± 2.13 for the amplified one (paired t-test: P < .0001). This study showed that practitioners would be better helped in hearing cardiac and respiratory sounds with an electronically amplified stethoscope than with a traditional one during air medical transport in a medically configured Falcon 50 aircraft. Copyright © 2014 Air Medical Journal Associates. Published by Elsevier Inc. All rights reserved.

  7. On stethoscope design: a challenge for biomedical circuit designers.

    PubMed

    Hahn, A W

    2001-01-01

    Most clinicians learned the art and science of auscultation using an acoustic stethoscope. While many models of electronic stethoscopes have been marketed over the years, none of them seem to do a very good job of emulating the most common forms of acoustic stethoscopes available. This paper is an appeal to biomedical circuit designers to learn more about the acoustics of commonly used stethoscopes and to develop an appropriate group of circuits which would emulate them much like music synthesizers can emulate almost any musical instrument. The implications are for creative designers to move toward a rational and acceptable design for both personal physician use and for telemedicine.

  8. Does the position or contact pressure of the stethoscope make any difference to clinical blood pressure measurements: an observational study.

    PubMed

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-12-01

    This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P < 0.001, 95% confidence interval -3.5 to -2.1 mm Hg). Since it is known that the traditional Korotkoff sound method, with the stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP.

  9. Does the Position or Contact Pressure of the Stethoscope Make Any Difference to Clinical Blood Pressure Measurements

    PubMed Central

    Pan, Fan; Zheng, Dingchang; He, Peiyu; Murray, Alan

    2014-01-01

    Abstract This study aimed to investigate the effect of stethoscope position and contact pressure on auscultatory blood pressure (BP) measurement. Thirty healthy subjects were studied. Two identical stethoscopes (one under the cuff, the other outside the cuff) were used to simultaneously and digitally record 2 channels of Korotkoff sounds during linear cuff pressure deflation. For each subject, 3 measurements with different contact pressures (0, 50, and 100 mm Hg) on the stethoscope outside the cuff were each recorded at 3 repeat sessions. The Korotkoff sounds were replayed twice on separate days to each of 2 experienced listeners to determine systolic and diastolic BPs (SBP and DBP). Variance analysis was performed to study the measurement repeatability and the effect of stethoscope position and contact pressure on BPs. There was no significant BP difference between the 3 repeat sessions, between the 2 determinations from each listener, between the 2 listeners and between the 3 stethoscope contact pressures (all P > 0.06). There was no significant SBP difference between the 2 stethoscope positions at the 2 lower stethoscope pressures (P = 0.23 and 0.45), but there was a small (0.4 mm Hg, clinically unimportant) significant difference (P = 0.005) at the highest stethoscope pressure. The key result was that, DBP from the stethoscope under the cuff was significantly lower than that from outside the cuff by 2.8 mm Hg (P < 0.001, 95% confidence interval −3.5 to −2.1 mm Hg). Since it is known that the traditional Korotkoff sound method, with the stethoscope outside the cuff, tends to give a higher DBP than the true intra-arterial pressure, this study could suggest that the stethoscope position under the cuff, and closer to the arterial occlusion, might yield measurements closer to the actual invasive DBP. PMID:25546675

  10. The bicentennial of the stethoscope: a reappraisal

    PubMed Central

    DAVID, LILIANA; DUMITRASCU, DAN L.

    2017-01-01

    Background and aim Two hundred years ago Laennec, a young French physician discovered the stethoscope, in order to improve the lung auscultation. The stethoscope became the emblematic appendix of the physicians. Nurses use it also to monitor patients and medical students are proud to use it. We critically review the significance of the stethoscope 200 years after its discovery. Methods Pertinent literature was searched on PubMed and Google about the stethoscope, using also other terms: auscultation, Laennec, medical education, clinical diagnosis. Data were collected in a narrative review. Results Two centuries after its invention, the stethoscope still remains a major tool in the hands of healthcare professionals. It is routinely used by medical doctors and has become a mark of their status. Nurses use it also to monitor heart rate and blood pressure. Medical students get familiarized to use it during the medical faculty. Patients perceive the stethoscope as an important symbol of the medical profession. Conclusions Two hundred years ago the stethoscope was invented by Laennec. Despite the advent of X rays, CT, ECG, echocardiography and more recently of the electronic stethoscope, the classical stethoscope invented by Laennec still has its major role in the representation of healthcare providers and is a major utility in clinical diagnosis. PMID:28781536

  11. USAARL Annual Progress Report Fiscal Year 2012

    DTIC Science & Technology

    2013-04-01

    analyzed. A technical report is currently in progress. A research project entitled “Clinical Assessment of the Noise Immune Stethoscope ” evaluated the...noise immune stethoscope (NIS), a dual mode electronic and Doppler device, at Madigan Army Medical Center. Insight from the evaluations, data...Immune Stethoscope aboard a U.S. Navy Carrier. (Report No. 2012-02). Fort Rucker, AL: U.S. Army Aeromedical Research Laboratory. Gordon, E., & Reeves

  12. Electronic stethoscope with frequency shaping and infrasonic recording capabilities.

    PubMed

    Gordon, E S; Lagerwerff, J M

    1976-03-01

    A small electronic stethoscope with variable frequency response characteristics has been developed for aerospace and research applications. The system includes a specially designed piezoelectric pickup and amplifier with an overall frequency response from 0.7 to 5,000 HZ (-3 dB points) and selective bass and treble boost or cut of up to 15 dB. A steep slope, high pass filter can be switched in for ordinary clinical auscultation without overload distortion from strong infrasonic signal inputs. A commercial stethoscope-type headset, selected for best overall response, is used which can adequately handle up to 100 mW of audio power delivered from the amplifier. The active components of the amplifier consist of only four opamp-type integrated circuits.

  13. Performance evaluation of heart sound cancellation in FPGA hardware implementation for electronic stethoscope.

    PubMed

    Chao, Chun-Tang; Maneetien, Nopadon; Wang, Chi-Jo; Chiou, Juing-Shian

    2014-01-01

    This paper presents the design and evaluation of the hardware circuit for electronic stethoscopes with heart sound cancellation capabilities using field programmable gate arrays (FPGAs). The adaptive line enhancer (ALE) was adopted as the filtering methodology to reduce heart sound attributes from the breath sounds obtained via the electronic stethoscope pickup. FPGAs were utilized to implement the ALE functions in hardware to achieve near real-time breath sound processing. We believe that such an implementation is unprecedented and crucial toward a truly useful, standalone medical device in outpatient clinic settings. The implementation evaluation with one Altera cyclone II-EP2C70F89 shows that the proposed ALE used 45% resources of the chip. Experiments with the proposed prototype were made using DE2-70 emulation board with recorded body signals obtained from online medical archives. Clear suppressions were observed in our experiments from both the frequency domain and time domain perspectives.

  14. In flight auscultation: comparison of electronic and conventional stethoscopes.

    PubMed

    Tourtier, Jean P; Fontaine, Emmamuelle; Coste, Sébastien; Ramsang, Solange; Schiano, Patrick; Viaggi, Marie; Libert, Nicolas; Durand, Xavier; Chargari, Cyrus; Borne, Marc

    2011-10-01

    The ability to auscultate during air medical transport is compromised by high ambient noise levels. The aim of this study was to assess the capabilities of a traditional and an amplified stethoscope (which is expected to reduce background and ambient noise) to assess heart and breath sounds during medical transport in a Falcon 50 plane. A prospective, double-blind, randomized study was performed. We tested 1 model of traditional stethoscope (Littman cardiology III) and 1 model of amplified stethoscope (Littman 3100). We studied heart and lung auscultation during real medical evacuations aboard Falcon 50 (medically configured). For each, the quality of auscultation was described using a numeric rating scale (ranging from 0 to 10, with 0 corresponding to "I hear nothing" and 10 corresponding to "I hear perfectly"). Comparisons were accomplished using a t test for paired values. A total of 32 comparative evaluations were performed. For cardiac auscultation, the value of the rating scale was 5.8 ± 1.5 and 6.4 ± 1.9, respectively, for the traditional and amplified stethoscope (P = .018). For lung sounds, quality of auscultation was estimated at 3.3 ± 2.4 for traditional stethoscope and at 3.7 ± 2.9 for amplified stethoscope (P = .15). Practicians in Falcon 50 are more able to hear cardiac sounds with an amplified than with a traditional stethoscope, whereas there is no significant difference concerning breath sounds auscultation. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Performance Evaluation of Heart Sound Cancellation in FPGA Hardware Implementation for Electronic Stethoscope

    PubMed Central

    Chao, Chun-Tang

    2014-01-01

    This paper presents the design and evaluation of the hardware circuit for electronic stethoscopes with heart sound cancellation capabilities using field programmable gate arrays (FPGAs). The adaptive line enhancer (ALE) was adopted as the filtering methodology to reduce heart sound attributes from the breath sounds obtained via the electronic stethoscope pickup. FPGAs were utilized to implement the ALE functions in hardware to achieve near real-time breath sound processing. We believe that such an implementation is unprecedented and crucial toward a truly useful, standalone medical device in outpatient clinic settings. The implementation evaluation with one Altera cyclone II–EP2C70F89 shows that the proposed ALE used 45% resources of the chip. Experiments with the proposed prototype were made using DE2-70 emulation board with recorded body signals obtained from online medical archives. Clear suppressions were observed in our experiments from both the frequency domain and time domain perspectives. PMID:24790573

  16. The correlation between the first heart sound and cardiac output as measured by using digital esophageal stethoscope under anaesthesia.

    PubMed

    Duck Shin, Young; Hoon Yim, Kyoung; Hi Park, Sang; Wook Jeon, Yong; Ho Bae, Jin; Soo Lee, Tae; Hwan Kim, Myoung; Jin Choi, Young

    2014-03-01

    The use of an esophageal stethoscope is a basic heart sounds monitoring procedure performed in patients under general anesthesia. As the size of the first heart sound can express the left ventricle function, its correlation with cardiac output should be investigated. The aim of this study was to investigate the effects of cardiac output (CO) on the first heart sound (S1) amplitude. Methods : Six male beagles were chosen. The S1 was obtained with the newly developed esophageal stethoscope system. CO was measured using NICOM, a non-invasive CO measuring device. Ephedrine and beta blockers were administered to the subjects to compare changes in figures, and the change from using an inhalation anesthetic was also compared. The S1 amplitude displayed positive correlation with the change rate of CO (r = 0.935, p < 0.001). The heart rate measured using the esophageal stethoscope and ECG showed considerably close figures through the Bland-Altman plot and showed a high positive correlation (r = 0.988, p < 0,001). In beagles, the amplitude of S1 had a significant correlation with changes in CO in a variety of situations.

  17. Validation of heart and lung teleauscultation on an Internet-based system.

    PubMed

    Fragasso, Gabriele; De Benedictis, Marialuisa; Palloshi, Altin; Moltrasio, Marco; Cappelletti, Alberto; Carlino, Mauro; Marchisi, Angelo; Pala, Mariagrazia; Alfieri, Ottavio; Margonato, Alberto

    2003-11-01

    The feasibility and accuracy of an Internet-based system for teleauscultation was evaluated in 103 cardiac patients, who were auscultated by the same cardiologist with a conventional stethoscope and with an Internet-based method, using an electronic stethoscope and transmitting heart and lung sounds between computer work stations. In 92% of patients, the results of electronic and acoustic auscultation coincided, indicating that teleauscultation may be considered a reliable method for assessing cardiac patients and could, therefore, be adopted in the context of comprehensive telecare programs.

  18. Cardiovascular Sound and the Stethoscope, 1816 to 2016

    PubMed Central

    Segall, Harold N.

    1963-01-01

    Cardiovascular sound escaped attention until Laennec invented and demonstrated the usefulness of the stethoscope. Accuracy of diagnosis using cardiovascular sounds as clues increased with improvement in knowledge of the physiology of circulation. Nearly all currently acceptable clinicopathological correlations were established by physicians who used the simplest of stethoscopes or listened with the bare ear. Certain refinements followed the use of modern methods which afford greater precision in timing cardiovascular sounds. These methods contribute to educating the human ear, so that those advantages may be applied which accrue from auscultation, plus the method of writing quantitative symbols to describe what is heard, by focusing the sense of hearing on each segment of the cardiac cycle in turn. By the year 2016, electronic systems of collecting and analyzing data about the cardiovascular system may render the stethoscope obsolete. ImagesFig. 1Fig. 2Fig. 3Fig. 5Fig. 8 PMID:13987676

  19. Continuous monitoring of blood pressure by analyzing the blood flow sound of arteriovenous fistula in hemodialysis patients.

    PubMed

    Kamijo, Yuka; Kanda, Eiichiro; Horiuchi, Hayato; Kounoue, Noriyuki; Ono, Keisuke; Maeda, Keizo; Yanai, Akane; Honda, Kazuya; Tsujimoto, Ryuji; Yanagi, Mai; Ishibashi, Yoshitaka; Yoshida, Masayuki

    2018-06-01

    Patients with end-stage renal disease undergoing hemodialysis (HD) have an elevated risk of cardiovascular disease-related morbidity and mortality. To prevent from such a life-threatening event, the continuous blood pressure (BP) monitoring system may contribute to detect BP decline in early stages and may help to do appropriate disposal. Our research team has introduced an electronic stethoscope (Asahi Kasei Co, Ltd., Tokyo, Japan), which translates sound intensity of Arteriovenous Fistula (AVF) to BP data using the technique of Fourier transformation that can predict continuous BP non-invasively. This study, we investigated whether electronic stethoscope-guided estimated BP (e-BP) would actually reflect systolic BP measured by sphygmomanometer (s-BP), and whether e-BP could predict fall of BP during HD. Twenty-six patients who underwent HD treatment in our hospital were evaluated prospectively. We obtained sound intensity data from the electronic stethoscope which was equipped with the return line of HD. Then, the data were translated into e-BP data to be compared with s-BP. Correlation of total of 315 data sets obtained from each method was examined. An accuracy of diagnosis of intra-dialytic hypotension (IDH) was evaluated. Total of 315 data sets were obtained. A close correlation was observed between e-BP and s-BP (r = 0.887, p < 0.0001). Sensitivity and positive predictive value of predicted-BP for detection of IDH was 90 and 81.3%, respectively. Electronic stethoscope-guided BP measurement would be helpful for real-time diagnosis of BP fall in HD patients. Further investigations are needed.

  20. [Computer-aided Diagnosis and New Electronic Stethoscope].

    PubMed

    Huang, Mei; Liu, Hongying; Pi, Xitian; Ao, Yilu; Wang, Zi

    2017-05-30

    Auscultation is an important method in early-diagnosis of cardiovascular disease and respiratory system disease. This paper presents a computer-aided diagnosis of new electronic auscultation system. It has developed an electronic stethoscope based on condenser microphone and the relevant intelligent analysis software. It has implemented many functions that combined with Bluetooth, OLED, SD card storage technologies, such as real-time heart and lung sounds auscultation in three modes, recording and playback, auscultation volume control, wireless transmission. The intelligent analysis software based on PC computer utilizes C# programming language and adopts SQL Server as the background database. It has realized play and waveform display of the auscultation sound. By calculating the heart rate, extracting the characteristic parameters of T1, T2, T12, T11, it can analyze whether the heart sound is normal, and then generate diagnosis report. Finally the auscultation sound and diagnosis report can be sent to mailbox of other doctors, which can carry out remote diagnosis. The whole system has features of fully function, high portability, good user experience, and it is beneficial to promote the use of electronic stethoscope in the hospital, at the same time, the system can also be applied to auscultate teaching and other occasions.

  1. A simple computer-based measurement and analysis system of pulmonary auscultation sounds.

    PubMed

    Polat, Hüseyin; Güler, Inan

    2004-12-01

    Listening to various lung sounds has proven to be an important diagnostic tool for detecting and monitoring certain types of lung diseases. In this study a computer-based system has been designed for easy measurement and analysis of lung sound using the software package DasyLAB. The designed system presents the following features: it is able to digitally record the lung sounds which are captured with an electronic stethoscope plugged to a sound card on a portable computer, display the lung sound waveform for auscultation sites, record the lung sound into the ASCII format, acoustically reproduce the lung sound, edit and print the sound waveforms, display its time-expanded waveform, compute the Fast Fourier Transform (FFT), and display the power spectrum and spectrogram.

  2. Polyvinylidene fluoride (PVDF) vibration sensor for stethoscope and contact microphones

    NASA Astrophysics Data System (ADS)

    Toda, Minoru; Thompson, Mitchell

    2005-09-01

    This paper describes a new type of contact vibration sensor made by bonding piezoelectric PVDF film to a curved frame structure. The concave surface of the film is bonded to a rubber piece having a front contact face. Vibration is transmitted from this face through the rubber to the surface of the PVDF film. Pressure normal to the surface of the film is converted to circumferential strain, and an electric field is induced by the piezoelectric effect. The frequency response of the device was measured using an accelerometer mounted between the rubber face and a rigid vibration exciter plate. Sensitivity (voltage per unit displacement) was deduced from the device output and measured acceleration. The sensitivity was flat from 16 Hz to 3 kHz, peaking at 6 kHz due to a structural resonance. Calculations predicting performance against human tissue (stethoscope or contact microphone) show results similar to data measured against the metal vibrator. This implies that an accelerometer can be used for calibrating a stethoscope or contact microphone. The observed arterial pulse waveform showed more low-frequency content than a conventional electronic stethoscope.

  3. Using K-Nearest Neighbor Classification to Diagnose Abnormal Lung Sounds

    PubMed Central

    Chen, Chin-Hsing; Huang, Wen-Tzeng; Tan, Tan-Hsu; Chang, Cheng-Chun; Chang, Yuan-Jen

    2015-01-01

    A reported 30% of people worldwide have abnormal lung sounds, including crackles, rhonchi, and wheezes. To date, the traditional stethoscope remains the most popular tool used by physicians to diagnose such abnormal lung sounds, however, many problems arise with the use of a stethoscope, including the effects of environmental noise, the inability to record and store lung sounds for follow-up or tracking, and the physician’s subjective diagnostic experience. This study has developed a digital stethoscope to help physicians overcome these problems when diagnosing abnormal lung sounds. In this digital system, mel-frequency cepstral coefficients (MFCCs) were used to extract the features of lung sounds, and then the K-means algorithm was used for feature clustering, to reduce the amount of data for computation. Finally, the K-nearest neighbor method was used to classify the lung sounds. The proposed system can also be used for home care: if the percentage of abnormal lung sound frames is > 30% of the whole test signal, the system can automatically warn the user to visit a physician for diagnosis. We also used bend sensors together with an amplification circuit, Bluetooth, and a microcontroller to implement a respiration detector. The respiratory signal extracted by the bend sensors can be transmitted to the computer via Bluetooth to calculate the respiratory cycle, for real-time assessment. If an abnormal status is detected, the device will warn the user automatically. Experimental results indicated that the error in respiratory cycles between measured and actual values was only 6.8%, illustrating the potential of our detector for home care applications. PMID:26053756

  4. A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

    PubMed Central

    Parsaei, H.; Vakily, A.; Shafiei, A.M.

    2017-01-01

    Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is unsuitable for observing inaccessible patients in some conditions such as during CT scan. Objective: A wireless electronic esophageal stethoscope is designed for continues auscultation of heart and lung sounds in anesthetized patients. The system consists of a transmitter and a receiver. The former acquires, amplifies and transmits the acquired sound signals to the latter via a frequency modulation transmitter. The receiver demodulates, amplifies, and delivers the received signal to a headphone to be heard by anesthesiologist. Results: The usability and effectiveness of the designed system was qualitatively evaluated by 5 anesthesiologists in Namazi Hospital and Shahid Chamran Hospital, Shiraz, Iran on 30 patients in several operating rooms in different conditions; e.g., when electro surgery instruments are working. Fortunately, the experts on average ranked good quality for the heard heart and lung sounds and very good on the user friendly being of the instrument. Conclusion: Evaluation results demonstrate that the developed system is capable of capturing and transmitting heart and lung sounds successfully. Therefore, it can be used to continuously monitor anesthetized patients’ cardiac and respiratory function. Since via the instrument wireless auscultation is possible, it could be suitable for observing inaccessible patients in several conditions such as during CT scan. PMID:28451580

  5. Randomised controlled trial of intrapartum fetal heart rate monitoring.

    PubMed

    Mahomed, K; Nyoni, R; Mulambo, T; Kasule, J; Jacobus, E

    1994-02-19

    To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. Prospective randomised controlled trial. Referral maternity hospital, Harare, Zimbabwe. 1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources.

  6. Randomised controlled trial of intrapartum fetal heart rate monitoring.

    PubMed Central

    Mahomed, K.; Nyoni, R.; Mulambo, T.; Kasule, J.; Jacobus, E.

    1994-01-01

    OBJECTIVE--To compare effectiveness of different methods of monitoring intrapartum fetal heart rate. DESIGN--Prospective randomised controlled trial. SETTING--Referral maternity hospital, Harare, Zimbabwe. SUBJECTS--1255 women who were 37 weeks or more pregnant with singleton cephalic presentation and normal fetal heart rate before entry into study. INTERVENTIONS--Intermittent monitoring of fetal heart rate by electronic monitoring, Doppler ultrasound, use of Pinard stethoscope by a research midwife, or routine use of Pinard stethoscope by attending midwife. MAIN OUTCOME MEASURES--Abnormal fetal heart rate patterns, need for operative delivery for fetal distress, neonatal mortality, Apgar scores, admission to neonatal unit, neonatal seizures, and hypoxic ischaemic encephalopathy. RESULTS--Abnormalities in fetal heart rate were detected in 54% (172/318) of the electronic monitoring group, 32% (100/312) of the ultrasonography group, 15% (47/310) of the Pinard stethoscope group, and 9% (28/315) of the routine monitoring group. Caesarean sections were performed for 28% (89%), 24% (76), 10% (32), and 15% (46) of the four groups respectively. Neonatal outcome was best in the ultrasonography group: hypoxic ischaemic encephalopathy occurred in two, one, seven, and 10 cases in the four groups respectively; neonatal seizures occurred only in the last two groups (six and nine cases respectively); and deaths occurred in eight, two, five, and nine cases respectively. CONCLUSIONS--Abnormalities in fetal heart rate were more reliably detected by Doppler ultrasonography than with Pinard stethoscope, and its use resulted in good perinatal outcome. The use of relatively cheap ultrasound monitors should be further evaluated and promoted in obstetric units caring for high risk pregnancies in developing countries with scarce resources. PMID:8136665

  7. BACTERIAL CONTAMINATION OF STETHOSCOPES

    PubMed Central

    Bukharie, Huda A.; Al-Zahrani, Hussain; Rubaish, Abdullah M.; Abdulmohsen, Mohammed F.

    2004-01-01

    Background: A stethoscope, an essential tool of the medical profession, can become a source of nosocomial infection. Objective: To determine the frequency of bacterial contamination of stethoscopes as well as the practices used for cleaning them. Methods: Cultures were taken from 100 stethoscopes used by different medical personnel in different hospital services. The stethoscopes were collected while the staff filled in a questionnaire. Results: Thirty (30%) out of the 100 stethoscopes surveyed were contaminated with microorganisms. The majority of organisms isolated were gram-positive bacteria (gram positive bacilli 12%, gram-negative bacteria 9%, gram-positive cocci 9%). None of the stethoscopes grew methicillin-resistant staphylococcus aureus. Overall, 21% of the health personnel cleaned their stethoscopes daily, 47% weekly, and 32% yearly. None of the health care workers cleaned their stethoscopes after every patient. Nurses cleaned their stethoscopes more often than physicians and medical students. Conclusion: Stethoscopes may be important in the spread of infectious agents. Their regular disinfection after use on each patient should be considered, particularly in such areas of the hospital, as the critical care units, and oncology units which house many patients with antibiotic-resistant organisms. PMID:23012043

  8. Characterization of Cardiac Time Intervals in Healthy Bonnet Macaques (Macaca radiata) by Using an Electronic Stethoscope

    PubMed Central

    Kamran, Haroon; Salciccioli, Louis; Pushilin, Sergei; Kumar, Paraag; Carter, John; Kuo, John; Novotney, Carol; Lazar, Jason M

    2011-01-01

    Nonhuman primates are used frequently in cardiovascular research. Cardiac time intervals derived by phonocardiography have long been used to assess left ventricular function. Electronic stethoscopes are simple low-cost systems that display heart sound signals. We assessed the use of an electronic stethoscope to measure cardiac time intervals in 48 healthy bonnet macaques (age, 8 ± 5 y) based on recorded heart sounds. Technically adequate recordings were obtained from all animals and required 1.5 ± 1.3 min. The following cardiac time intervals were determined by simultaneously recording acoustic and single-lead electrocardiographic data: electromechanical activation time (QS1), electromechanical systole (QS2), the time interval between the first and second heart sounds (S1S2), and the time interval between the second and first sounds (S2S1). QS2 was correlated with heart rate, mean arterial pressure, diastolic blood pressure, and left ventricular ejection time determined by using echocardiography. S1S2 correlated with heart rate, mean arterial pressure, diastolic blood pressure, left ventricular ejection time, and age. S2S1 correlated with heart rate, mean arterial pressure, diastolic blood pressure, systolic blood pressure, and left ventricular ejection time. QS1 did not correlate with any anthropometric or echocardiographic parameter. The relation S1S2/S2S1 correlated with systolic blood pressure. On multivariate analyses, heart rate was the only independent predictor of QS2, S1S2, and S2S1. In conclusion, determination of cardiac time intervals is feasible and reproducible by using an electrical stethoscope in nonhuman primates. Heart rate is a major determinant of QS2, S1S2, and S2S1 but not QS1; regression equations for reference values for cardiac time intervals in bonnet macaques are provided. PMID:21439218

  9. The stethoscope and healthcare-associated infection: a snake in the grass or innocent bystander?

    PubMed

    O'Flaherty, N; Fenelon, L

    2015-09-01

    There is a concern that stethoscopes may transmit infectious agents which could result in healthcare-associated infection (HCAI). The aim of this review was to evaluate the available literature as to the role of the stethoscope in the development of HCAI. A literature search was conducted across several databases for relevant studies and reports. Stethoscopes were consistently shown to harbour bacteria. The mean rate of stethoscope contamination across 28 studies was 85% (range: 47-100%). The majority of bacteria isolated were deemed to be non-pathogenic. The most frequently isolated organisms were coagulase-negative staphylococci. The mean level of contamination was in excess of the French Normalization standard for cleanliness (which equates to <20 colony-forming units per membrane) in all six studies in which contamination levels were quantified. Potentially pathogenic organisms cultured from stethoscopes included: Staphylococcus aureus, Pseudomonas aeruginosa, vancomycin-resistant enterococci, and Clostridium difficile. There was evidence that bacteria can transfer from the skin of the patient to the stethoscope and from the stethoscope to the skin. However, studies were not designed to detect a correlation between stethoscope contamination and subsequent HCAI. Surveys assessing cleaning practices revealed a suboptimal commitment to stethoscope disinfection among doctors and medical students. The optimum method for stethoscope cleaning has not been defined, although alcohol-based disinfectants are effective in reducing bacterial contamination. In conclusion, a link between contaminated stethoscopes and HCAI has not yet been confirmed, but transfer of bacteria between skin and stethoscope has been shown. The available information would suggest that stethoscopes should be decontaminated between patients. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  10. What's growing on your stethoscope? (And what you can do about it).

    PubMed

    Schroeder, Ariel; Schroeder, Maryellen A; D'Amico, Frank

    2009-08-01

    Studies have shown that rubbing alcohol pads on stethoscope diaphragms can reduce bacterial colonization, but alcohol pads are used infrequently used and not always available. We conducted a prospective, single-blinded study to investigate whether simultaneously scrubbing hands and stethoscope head with alcohol-based hand foam would significantly reduce bacterial counts on the stethoscope. Using their own stethoscope, participants imprinted the stethoscope head onto a chocolate agar plate, then used alcohol-based hand foam to cleanse their hands while simultaneously rubbing the stethoscope head. Once the stethoscope heads were dry, the participants imprinted their stethoscope heads onto a second plate. After 48 hours' incubation, we determined the bacterial counts for the prewash and post-wash plates, and compared the 2. We analyzed a total of 184 cultures (from 92 stethoscopes). Both the mean (28 prewash vs 3 post-wash, P=.001) and median (11 prewash vs 1 post-wash, P=.001) colony counts were significantly greater before being cleansed. Three methicillin-resistant Staphylococcus aureus (MRSA) colonies were identified in the prewash period; all were destroyed by the foam. The estimated number of hand washes needed to prevent 1 MRSA colony is 31 (95% confidence interval [CI], 18-89). Simultaneously using hand foam to clean hands and stethoscope heads reduces bacterial counts on stethoscopes. Further research is needed to determine whether this intervention can reduce morbidity and mortality associated with bacterial infection.

  11. [Bacterial contamination of stethoscopes in hospital].

    PubMed

    Davullu, Sevcan; Burger, Sandrine; Kessler, Brigitte; Meunier, Olivier

    2015-01-01

    Although many publications on the subject are available, only few campaigns for stethoscopes cleaning and disinfection are conducted. Stethoscope is a "not critical" reusable medical device and should benefit from a cleaning disinfection "low level" after each use. We studied the bacterial contamination of stethoscopes in our hospital and measured the role of bacterial reservoir and/or vector stethoscope could play. Mean microbial load was estimated at 1.550 CFU per stethoscope. Results obtained in our hospital and those of the literature, led us to propose a simple and efficient cleaning method. We believe motivate everyone to change their habits and carry out disinfection more frequent their very handling stethoscope.

  12. Stethoscope disinfection campaign in a Nigerian teaching hospital:results of a before-and-after study.

    PubMed

    Uneke, Chigozie J; Ndukwe, Chinwendu D; Nwakpu, Kingsley O; Nnabu, Richard C; Ugwuoru, Cletus D; Prasopa-Plaizier, Nittita

    2014-01-15

    This study aimed to assess the impact of a stethoscope disinfection sensitization campaign among doctors and nurses in a Nigerian teaching hospital. The design was a before-and-after study. Pre-program measurements were used to provide a baseline against which the post-program results were compared. Interventions that promoted compliance with stethoscope disinfection practice that were implemented included training and education on stethoscope disinfection and introduction of 70% isopropyl alcohol disinfectant at points-of-care places. Microbiological assessment of stethoscopes used by health workers was conducted after the intervention and the outcome was compared with the pilot study results. After the intervention, of the 89 stethoscopes screened, 18 (20.2%) were contaminated with bacterial agents. A higher prevalence of stethoscope contamination was observed among stethoscopes from the intensive care unit (66.7%), the VIP unit (50%), and the antenatal unit (37.5%). The main isolates were Staphylococcus aureus (44.4%) and Escherichia coli (50%). The antibiotic sensitivity assessment indicated that the bacterial isolates were resistant to nearly all the antibiotics tested. All the 89 health workers whose stethoscopes were screened after the intervention admitted to cleaning their stethoscopes after seeing each patient, representing a compliance rate of 100%, unlike the 15% compliance at the pilot phase. The baseline stethoscope contamination rate was 78.5% versus 20.2% post-intervention. Training and education and introduction of alcohol-based disinfectants inexpensive but very effective methods to improve stethoscope disinfection compliance among health workers in low-income settings.

  13. Bacteriological assessment of stethoscopes used by healthcare workers in a tertiary care centre of Nepal.

    PubMed

    Thapa, Sangita; Sapkota, Lokendra Bahadur

    2017-07-28

    Stethoscope is a medical device universally used by health care workers. Stethoscope may transmit pathogens among patients and health care workers if it is not disinfected. The objective of this study was to, determine the level of stethoscope contamination used by health care workers, survey the practices of disinfecting the stethoscope, identify various microorganisms and assess their role as potential pathogens and determine the effectiveness of 70% ethanol as a disinfecting agent. This was a cross-sectional study conducted in the department of Microbiology, Chitwan Medical College, Bharatpur, Nepal. Stethoscopes of 122 health care workers from different departments were included in this study. Out of a total 122 diaphragms, 88 (72.1%) were colonized. Only 71 (58.1%) bells and 152 earpieces (66.2%) were contaminated. Micrococcus and coagulase negative staphylococci were predominantly isolated species. The contamination was lowest among stethoscopes cleaned after touching every patient (11.5%) and the difference is statistically significant (P < 0.0001). Significantly lower level of contamination (13.6%) were found on stethoscopes cleaned everyday (P < 0.0001). Only 8.5% stethoscope showed growth with decreased number of colonies after disinfecting the stethoscopes with 70% ethanol. Thus, demonstrating the effectiveness of disinfection.

  14. Digital auscultation of the uterine artery: a measure of uteroplacental perfusion.

    PubMed

    Riknagel, Diana; Dinesen, Birthe; Zimmermann, Henrik; Farlie, Richard; Schmidt, Samuel; Toft, Egon; Struijk, Johannes Jan

    2016-07-01

    This observational study investigated digital auscultation for the purpose of assessing the clinical feasibility of monitoring vascular sounds in pregnancy. The study was performed at the Regional Hospital Viborg, Denmark, and included 29 pregnant women, 10 non-pregnant women and 10 male participants. Digital auscultation was performed with an electronic stethoscope bilaterally near the uterine arteries and correlated to the clinical diagnosis of preeclampsia (PE), intrauterine growth restriction (IUGR) or normal pregnancy in the group of pregnant participants. In the group of non-pregnant participants, digital auscultation was performed as control measurements in the same anatomical positions. The auscultations displayed pulse waveforms comprising systolic and diastolic periods in 20 of the 29 pregnant participants. However, in the non-pregnant and male participants, the pulse waveforms were absent. The pulsatile patterns are thus likely to originate from the arteries in relation to the pregnant uterus. In the participants displaying pulse waveforms, the presence of a dicrotic notch appeared with a sensitivity of 89% and a specificity of 100% in the discrimination of normal pregnancies (n  =  11) from pregnancies with PE or IUGR (n  =  9), (p  <  0.001). This preliminary study shows the potential of identifying vascular complications during pregnancy such as preeclampsia and intrauterine growth restriction. The morphology of the derived pulse contour should be investigated and could be further developed to identify pathophysiology.

  15. Cross-sectional study of frequency and factors associated with stethoscope cleaning among medical practitioners in Pakistan.

    PubMed

    Hyder, O

    2012-07-01

    Stethoscope diaphragms are frequently colonized by bacteria. This cross-sectional study described the frequency and factors associated with reporting ever cleaning stethoscopes among 408 medical students and doctors at a medical college and 2 teaching hospitals in Rawalpindi, Pakistan. A minority of the respondents (37.7%) reported having ever cleaned their stethoscope. Following normal clinical use, wiping with a dry cloth was the most frequently reported method of cleaning (53.2%). After contamination of the diaphragm with blood or secretions, cleaning with an alcoholic swab was the most common method (64.3%). In univariate and multivariate analyses, history of receiving information on stethoscope cleaning, utilization of personal stethoscope at last use and affiliation with internal medicine department were factors strongly associated with ever cleaning of stethoscope. Future research for improving stethoscope cleaning practices should explore educational interventions aimed at health care professionals.

  16. Bacterial contamination of stethoscopes on the intensive care unit.

    PubMed

    Whittington, A M; Whitlow, G; Hewson, D; Thomas, C; Brett, S J

    2009-06-01

    We assessed how often bedside stethoscopes in our intensive care unit were cleaned and whether they became colonised with potentially pathogenic bacteria. On two separate days the 12 nurses attending the bedspaces were questioned about frequency of stethoscope cleaning on the unit and the bedside stethoscopes were swabbed before and after cleaning to identify colonising organisms. Twenty-two health care providers entering the unit were asked the same questions and had their personal stethoscopes swabbed. All 32 non-medical staff cleaned their stethoscopes at least every day; however only three out of the 12 medical staff cleaned this often. Out of 24 intensive care unit bedside stethoscopes tested, two diaphragms and five earpieces were colonised with pathogenic bacteria. MRSA cultured from one earpiece persisted after cleaning. Three out of the 22 personal stethoscope diaphragms and five earpieces were colonised with pathogens. After cleaning, two diaphragms and two earpieces were still colonised, demonstrating the importance of regular cleaning.

  17. [The invention and evolution of the stethoscope].

    PubMed

    Hong, Cheng; Wang, Wei; Zhong, Nan-Shan; Liu, Yuan-Ming

    2010-11-01

    There is a record of direct auscultation in the Hippocratic Corpus and this auscultation method has been used for more than 2000 years. In 1816, the first monaural stethoscope was invented by a French physician Dr. Rene Laennec, who also wrote books introducing how to use the stethoscope and auscultation. This instrument has been improved by several doctors and in 1851,the one improved by George Cammann, an American doctor, was the model of today's stethoscope. The electrical stethoscope was produced by the 3M(TM) Littmann Company in 1999, after which the audio files could be saved. In 2000, the vibration response imaging system was introduced into medicine. In 2006, a noise-free active stethoscope was displayed in the Acoustics Conference held in Honolulu, USA. This kind of stethoscope could be used in noisy or bumpy circumstances. These new pieces of equipment made the stethoscope's application field even broader.

  18. Improving stethoscope disinfection at a children's hospital.

    PubMed

    Zaghi, Justin; Zhou, Jing; Graham, Dionne A; Potter-Bynoe, Gail; Sandora, Thomas J

    2013-11-01

    Stethoscopes are contaminated with pathogenic bacteria and pose a risk for transmission of infections, but few clinicians disinfect their stethoscope after every use. We sought to improve stethoscope disinfection rates among pediatric healthcare providers by providing access to disinfection materials and visual reminders to disinfect stethoscopes. Prospective intervention study. Inpatient units and emergency department of a major pediatric hospital. Physicians and nurses with high anticipated stethoscope use. Baskets filled with alcohol prep pads and a sticker reminding providers to regularly disinfect stethoscopes were installed outside of patient rooms. Healthcare providers' stethoscope disinfection behaviors were directly observed before and after the intervention. Multivariable logistic regression models were created to identify independent predictors of stethoscope disinfection. Two hundred twenty-six observations were made in the preintervention period and 261 in the postintervention period (83% were of physicians). Stethoscope disinfection compliance increased significantly from a baseline of 34% to 59% postintervention (P < .001). In adjusted analyses, the postintervention period was associated with improved disinfection among both physicians (odds ratio [OR], 2.3 [95% confidence interval (CI), 1.4-3.5]) and nurses (OR, 14.3 [95% CI, 4.6-44.6]). Additional factors independently associated with disinfection included subspecialty unit (vs general pediatrics; OR, 0.5 [95% CI, 0.3-0.8]) and contact precautions (OR, 2.3 [95% CI, 1.2-4.1]). Providing stethoscope disinfection supplies and visible reminders outside of patient rooms significantly increased stethoscope disinfection rates among physicians and nurses at a children's hospital. This simple intervention could be replicated at other healthcare facilities. Future research should assess the impact on patient infections.

  19. Variation of the Korotkoff Stethoscope Sounds During Blood Pressure Measurement: Analysis Using a Convolutional Neural Network.

    PubMed

    Pan, Fan; He, Peiyu; Liu, Chengyu; Li, Taiyong; Murray, Alan; Zheng, Dingchang

    2017-11-01

    Korotkoff sounds are known to change their characteristics during blood pressure (BP) measurement, resulting in some uncertainties for systolic and diastolic pressure (SBP and DBP) determinations. The aim of this study was to assess the variation of Korotkoff sounds during BP measurement by examining all stethoscope sounds associated with each heartbeat from above systole to below diastole during linear cuff deflation. Three repeat BP measurements were taken from 140 healthy subjects (age 21 to 73 years; 62 female and 78 male) by a trained observer, giving 420 measurements. During the BP measurements, the cuff pressure and stethoscope signals were simultaneously recorded digitally to a computer for subsequent analysis. Heartbeats were identified from the oscillometric cuff pressure pulses. The presence of each beat was used to create a time window (1 s, 2000 samples) centered on the oscillometric pulse peak for extracting beat-by-beat stethoscope sounds. A time-frequency two-dimensional matrix was obtained for the stethoscope sounds associated with each beat, and all beats between the manually determined SBPs and DBPs were labeled as "Korotkoff." A convolutional neural network was then used to analyze consistency in sound patterns that were associated with Korotkoff sounds. A 10-fold cross-validation strategy was applied to the stethoscope sounds from all 140 subjects, with the data from ten groups of 14 subjects being analyzed separately, allowing consistency to be evaluated between groups. Next, within-subject variation of the Korotkoff sounds analyzed from the three repeats was quantified, separately for each stethoscope sound beat. There was consistency between folds with no significant differences between groups of 14 subjects (P = 0.09 to P = 0.62). Our results showed that 80.7% beats at SBP and 69.5% at DBP were analyzed as Korotkoff sounds, with significant differences between adjacent beats at systole (13.1%, P = 0.001) and diastole (17.4%, P < 0.001). Results reached stability for SBP (97.8%, at sixth beat below SBP) and DBP (98.1%, at sixth beat above DBP) with no significant differences between adjacent beats (SBP P = 0.74; DBP P = 0.88). There were no significant differences at high-cuff pressures, but at low pressures close to diastole there was a small difference (3.3%, P = 0.02). In addition, greater within subject variability was observed at SBP (21.4%) and DBP (28.9%), with a significant difference between both (P < 0.02). In conclusion, this study has demonstrated that Korotkoff sounds can be consistently identified during the period below SBP and above DBP, but that at systole and diastole there can be substantial variations that are associated with high variation in the three repeat measurements in each subject.

  20. 21 CFR 868.1910 - Esophageal stethoscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Esophageal stethoscope. 868.1910 Section 868.1910...) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1910 Esophageal stethoscope. (a) Identification. An esophageal stethoscope is a nonpowered device that is inserted into a patient's esophagus to...

  1. Examination of staphylococcal stethoscope contamination in the emergency department (pilot) study (EXSSCITED pilot study).

    PubMed

    Tang, Patrick H P; Worster, Andrew; Srigley, Jocelyn A; Main, Cheryl L

    2011-07-01

    The objective of this study was to determine the prevalence of Staphylococcus-contaminated stethoscopes belonging to emergency department (ED) staff and to identify the proportion of these that were Staphylococcus aureus or methicillin-resistant Staphylococcus aureus (MRSA). We conducted a prospective observational cohort study of bacterial cultures from 100 ED staff members' stethoscopes at three EDs. Study participants were asked to complete a questionnaire. Fifty-four specimens grew coagulase-negative staphylococci and one grew methicillin-susceptible S. aureus. No MRSA was cultured. Only 8% of participants, all of whom were nurses, reported cleaning their stethoscope before or after each patient assessment. Alcohol-based wipes were most commonly used to clean stethoscopes. A lack of time, being too busy, and forgetfulness were the most frequently reported reasons for not cleaning the stethoscope in the ED. This study indicates that although stethoscope contamination rates in these EDs are high, the prevalence of S. aureus or MRSA on stethoscopes is low.

  2. 21 CFR 868.1920 - Esophageal stethoscope with electrical conductors.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Esophageal stethoscope with electrical conductors... stethoscope with electrical conductors. (a) Identification. An esophageal stethoscope with electrical conductors is a device that is inserted into the esophagus to listen to a patient's heart and breath sounds...

  3. 21 CFR 868.1920 - Esophageal stethoscope with electrical conductors.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Esophageal stethoscope with electrical conductors... stethoscope with electrical conductors. (a) Identification. An esophageal stethoscope with electrical conductors is a device that is inserted into the esophagus to listen to a patient's heart and breath sounds...

  4. 21 CFR 868.1930 - Stethoscope head.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Stethoscope head. 868.1930 Section 868.1930 Food... DEVICES ANESTHESIOLOGY DEVICES Diagnostic Devices § 868.1930 Stethoscope head. (a) Identification. A stethoscope head is a weighted chest piece used during anesthesia to listen to a patient's heart, breath, and...

  5. Development of a tele-stethoscope and its application in pediatric cardiology.

    PubMed

    Hedayioglu, F L; Mattos, S S; Moser, L; de Lima, M E

    2007-01-01

    Over the years, many attempts have been made to develop special stethoscopes for the teaching of auscultation. The objective of this article is to report on the experience with the development and implementation of an electronic stethoscope and a virtual library of cardiac sounds. There were four stages to this project: (1) the building of the prototype to acquire, filter and amplify the cardiac sounds, (2) the development of a software program to record, reproduce and visualize them, (3) the testing of the prototype in a clinical scenario, and (4) the development of an internet site, to store and display the sounds collected. The first two stages are now complete. The prototype underwent an initial evaluation in a clinical scenario within the Unit and during virtual out-patient clinical sessions. One hundred auscultations were recorded during these tests. They were reviewed and discussed on-line by a panel of experience cardiologists during the sessions. Although the sounds were considered "satisfactory" for diagnostic purposes by the cardiology team, they identified some qualitative differences in the electronic recorded auscultations, such as a higher pitch of the recorded sounds. Prospective clinical studies are now being conducted to further evaluate the interference of the electronic device in the physicians' capability to diagnose different cardiac conditions. An internet site (www.caduceusvirtual.com.br/ auscultaped) was developed to host these cardiac auscultations. It is set as a library of cardiac sounds, catalogued by pathologies and already contains examples from auscultations of the majority of common congenital heart lesions, such as septal defects and valvar lesions.

  6. Stethoscope Cleaning During Patient Care.

    PubMed

    Ghumman, Ghazi Wahla; Ahmad, Nina; Pop-Vicas, Aurora; Iftikhar, Sadia

    2018-05-01

    We conducted a cross-sectional survey of healthcare workers in two community teaching hospitals to better understand clinicians' beliefs and practices related to cleaning of their stethoscopes. The study was conducted from September 2015 to May 2016. Among the total 358 responses received, 45%, 40%, 10% and 5% were from attending physicians, medical students, nurses, and resident physicians, respectively. Although the majority of the respondents (76%) frequently used a stethoscope at work, and almost all (93%) believed that stethoscopes can be involved in pathogen transmission, only 29% of participants reported cleaning their stethoscopes after every use. Hospitals should include stethoscope cleaning into their overall infection prevention efforts. [Full article available at http://rimed.org/rimedicaljournal-2018-05.asp].

  7. Stethoscope Hygiene: Practice and Attitude of Medical Students

    PubMed Central

    Gazibara, Tatjana; Radovanovic, Sanja; Maric, Gorica; Rancic, Biljana; Kisic-Tepavcevic, Darija; Pekmezovic, Tatjana

    2015-01-01

    Objective The purpose of this study was to evaluate the frequency and attitude of medical students towards cleaning their stethoscopes. Subjects and Methods A cross-sectional study was carried out in the first week of December 2013. The study included 771 students (397 in their fourth and 374 in their sixth year) from the Faculty of Medicine, University of Belgrade, Serbia. An anonymous questionnaire was distributed to students before the start of compulsory lessons in classrooms. Results 317 of the 397 fourth-year students (79.8%) and 306 of the 374 sixth-year students (81.9%) cleaned their stethoscope. The stethoscope diaphragm was most commonly cleaned, while the flexible tubing was the least commonly cleaned area, mainly using ethyl alcohol-based agents. The strongest positive attitude was observed for the statement ‘It is important that my stethoscope is clean’ (4.3 out of 5.0). A positive correlation (Spearman's ρ = 0.105) was observed between a higher frequency of cleaning and the stronger positive notion that a stethoscope should be cleaned. Conclusion A considerably high proportion of the students studied had ever cleaned their stethoscopes. Based on the students' responses, it would be useful to implement instructions on stethoscope hygiene in the regular practical curriculum with the aim of applying stethoscope disinfection in daily work. PMID:26202790

  8. Stethoscope Hygiene: Practice and Attitude of Medical Students.

    PubMed

    Gazibara, Tatjana; Radovanovic, Sanja; Maric, Gorica; Rancic, Biljana; Kisic-Tepavcevic, Darija; Pekmezovic, Tatjana

    2015-01-01

    The purpose of this study was to evaluate the frequency and attitude of medical students towards cleaning their stethoscopes. A cross-sectional study was carried out in the first week of December 2013. The study included 771 students (397 in their fourth and 374 in their sixth year) from the Faculty of Medicine, University of Belgrade, Serbia. An anonymous questionnaire was distributed to students before the start of compulsory lessons in classrooms. 317 of the 397 fourth-year students (79.8%) and 306 of the 374 sixth-year students (81.9%) cleaned their stethoscope. The stethoscope diaphragm was most commonly cleaned, while the flexible tubing was the least commonly cleaned area, mainly using ethyl alcohol-based agents. The strongest positive attitude was observed for the statement 'It is important that my stethoscope is clean' (4.3 out of 5.0). A positive correlation (Spearman's x03C1; = 0.105) was observed between a higher frequency of cleaning and the stronger positive notion that a stethoscope should be cleaned. A considerably high proportion of the students studied had ever cleaned their stethoscopes. Based on the students' responses, it would be useful to implement instructions on stethoscope hygiene in the regular practical curriculum with the aim of applying stethoscope disinfection in daily work. © 2015 S. Karger AG, Basel.

  9. Ethanol-based cleanser versus isopropyl alcohol to decontaminate stethoscopes.

    PubMed

    Lecat, Paul; Cropp, Elliott; McCord, Gary; Haller, Nairmeen Awad

    2009-04-01

    Approximately 1 in 20 hospital admissions is complicated by a health care-associated infection. Stethoscopes may play a role in spreading nosocomial infections. The objective of this study was to determine the effectiveness of an ethanol-based cleanser (EBC) compared with isopropyl alcohol pads in reducing bacterial contamination of stethoscope diaphragms. Stethoscopes were cultured from medical professionals on 4 medical floors before and after cleaning with either EBC or isopropyl alcohol pads. The numbers of colony-forming units (cfu) grown were compared between the 2 cleaners and to baseline values. A total of 99 stethoscopes were cultured (49 EBC; 50 isopropyl alcohol), and all were positive for growth. After cleaning, 28.28% of the stethoscopes were growth-free (12 EBC; 16 isopropyl alcohol). Cleaning with EBC and isopropyl alcohol pads significantly reduced the cfu counts (by 92.8% and 92.5%, respectively), but neither was found to be statistically superior (F = 1.22; P = .2721). Cleaning a stethoscope diaphragm using either EBC or isopropyl alcohol led to a significant reduction in bacterial growth in culture. As an extension of the hand, a stethoscope should be cleaned with the same frequency as the hands. The simultaneous cleaning of hands and stethoscope may further increase compliance with current standards.

  10. Stethoscopes with hearing aid use: Case studies

    PubMed Central

    Jacob, Regina Tangerino de Souza; Zambonato, Ticiana Cristina de Souza; Mondelli, Maria Fernanda Capoani Garcia

    2013-01-01

    Summary Introduction: Description for using stethoscopes adapted to hearing aids. Aim: To describe the adaptation of HAs to stethoscopes used by 2 students in the health field with bilateral hearing impairment. Case reports: Two subjects with hearing loss had their stethoscopes coupled to HAs because of the individual requirements of their professions (healthcare) to perform auscultation. Conclusion: The improvement was measured in situ, and satisfaction was evaluated using a subjective questionnaire. The use of a stethoscope coupled to an HA allowed students with hearing loss to perform auscultation. PMID:25992000

  11. Epidermal mechano-acoustic sensing electronics for cardiovascular diagnostics and human-machine interfaces.

    PubMed

    Liu, Yuhao; Norton, James J S; Qazi, Raza; Zou, Zhanan; Ammann, Kaitlyn R; Liu, Hank; Yan, Lingqing; Tran, Phat L; Jang, Kyung-In; Lee, Jung Woo; Zhang, Douglas; Kilian, Kristopher A; Jung, Sung Hee; Bretl, Timothy; Xiao, Jianliang; Slepian, Marvin J; Huang, Yonggang; Jeong, Jae-Woong; Rogers, John A

    2016-11-01

    Physiological mechano-acoustic signals, often with frequencies and intensities that are beyond those associated with the audible range, provide information of great clinical utility. Stethoscopes and digital accelerometers in conventional packages can capture some relevant data, but neither is suitable for use in a continuous, wearable mode, and both have shortcomings associated with mechanical transduction of signals through the skin. We report a soft, conformal class of device configured specifically for mechano-acoustic recording from the skin, capable of being used on nearly any part of the body, in forms that maximize detectable signals and allow for multimodal operation, such as electrophysiological recording. Experimental and computational studies highlight the key roles of low effective modulus and low areal mass density for effective operation in this type of measurement mode on the skin. Demonstrations involving seismocardiography and heart murmur detection in a series of cardiac patients illustrate utility in advanced clinical diagnostics. Monitoring of pump thrombosis in ventricular assist devices provides an example in characterization of mechanical implants. Speech recognition and human-machine interfaces represent additional demonstrated applications. These and other possibilities suggest broad-ranging uses for soft, skin-integrated digital technologies that can capture human body acoustics.

  12. Epidermal mechano-acoustic sensing electronics for cardiovascular diagnostics and human-machine interfaces

    PubMed Central

    Liu, Yuhao; Norton, James J. S.; Qazi, Raza; Zou, Zhanan; Ammann, Kaitlyn R.; Liu, Hank; Yan, Lingqing; Tran, Phat L.; Jang, Kyung-In; Lee, Jung Woo; Zhang, Douglas; Kilian, Kristopher A.; Jung, Sung Hee; Bretl, Timothy; Xiao, Jianliang; Slepian, Marvin J.; Huang, Yonggang; Jeong, Jae-Woong; Rogers, John A.

    2016-01-01

    Physiological mechano-acoustic signals, often with frequencies and intensities that are beyond those associated with the audible range, provide information of great clinical utility. Stethoscopes and digital accelerometers in conventional packages can capture some relevant data, but neither is suitable for use in a continuous, wearable mode, and both have shortcomings associated with mechanical transduction of signals through the skin. We report a soft, conformal class of device configured specifically for mechano-acoustic recording from the skin, capable of being used on nearly any part of the body, in forms that maximize detectable signals and allow for multimodal operation, such as electrophysiological recording. Experimental and computational studies highlight the key roles of low effective modulus and low areal mass density for effective operation in this type of measurement mode on the skin. Demonstrations involving seismocardiography and heart murmur detection in a series of cardiac patients illustrate utility in advanced clinical diagnostics. Monitoring of pump thrombosis in ventricular assist devices provides an example in characterization of mechanical implants. Speech recognition and human-machine interfaces represent additional demonstrated applications. These and other possibilities suggest broad-ranging uses for soft, skin-integrated digital technologies that can capture human body acoustics. PMID:28138529

  13. Predictors of Heavy Stethoscope Contamination Following a Physical Examination.

    PubMed

    Tschopp, Clément; Schneider, Alexis; Longtin, Yves; Renzi, Gesuele; Schrenzel, Jacques; Pittet, Didier

    2016-06-01

    BACKGROUND The degree of bacterial contamination of stethoscopes can vary significantly following a physical examination. OBJECTIVE To conduct a prospective study to investigate the impact of various environmental and patient characteristics on stethoscope contamination. METHODS Following a standardized examination, the levels of bacterial contamination of 4 regions of the physicians' hands and 2 sections of the stethoscopes, and the presence of different pathogenic bacteria, were assessed. Predictors of heavy stethoscope contamination were identified through multivariate logistic regression. RESULTS In total, 392 surfaces were sampled following examination of 56 patients. The microorganisms most frequently recovered from hands and stethoscopes were Enterococcus spp. (29% and 20%, respectively) and Enterobacteriaceae (16% and 7%, respectively). Staphylococcus aureus (either methicillin susceptible or resistant), extended-spectrum β-lactamase-producing Enterobacteriaceae, and Acinetobacter baumannii were recovered from 4%-9% of the samples from either hands or stethoscopes. There was a correlation between the likelihood of recovering these pathogens from the stethoscopes vs from the physicians' hands (ρ=0.79; P=.04). The level of patient's skin contamination was an independent predictor of contamination of the stethoscope diaphragm (adjusted odds ratio [aOR], 1.001; P=.007) and tube (aOR, 1.001; P=.003). Male sex (aOR, 28.24; P=.01) and reception of a bed bath (aOR, 7.52; P=.048) were also independently associated with heavy tube contamination. CONCLUSIONS Stethoscope contamination following a single physical examination is not negligible and is associated with the level of contamination of the patient's skin. Prevention of pathogen dissemination is needed. Infect Control Hosp Epidemiol 2016;37:673-679.

  14. Bacterial contamination of stethoscopes used by health workers: public health implications.

    PubMed

    Uneke, Chigozie J; Ogbonna, Annayo; Oyibo, Patrick G; Onu, Christian M

    2010-08-04

    This study was designed to assess both the potential for bacterial transmission by stethoscopes used by health-care workers in Nigeria and the implications for patient safety and control of hospital-acquired infections. A structured questionnaire was administered to health workers and the surface of the diaphragm of their stethoscopes swabbed for bacteriological analysis using standard techniques. Of the 107 stethoscopes surveyed, 84 (79%) were contaminated with bacteria; 59 (81%) of the contaminated stethoscopes belonged to physicians and 25 (74%) were from other health workers. Isolates included Staphylococcus aureus (54%), Pseudomonas aeruginosa (19%), Enterococcus faecalis (14%), and Escherichia coli (13%). All stethoscopes that had never been cleaned were contaminated while lower levels of contamination were found on those cleaned one week or less before the survey (chi(2) = 22.4, P < .05). Contamination was significantly higher on stethoscopes cleaned with only water (100%) compared to those cleaned with alcohol (49%) (chi(2) = 30.17, P < .05). Significantly fewer (9%) stethoscopes from health workers who washed their hands after seeing each patient were contaminated when compared with the instruments (86%) of those who did not practice hand washing (chi(2) = 23.79, P < .05). E. coli showed the highest antibiotic resistance, while S. aureus showed the highest antibiotic susceptibility. Strict adherence to stethoscope disinfection practices by health workers can minimize cross-contamination and ensure improved patient safety in hospital environments.

  15. A simplified form of cardiotocography for antenatal fetal assessment.

    PubMed

    Mahomed, K; Gupta, B K; Matikiti, L; Murape, T S

    1992-12-01

    Antenatal cardiotocography has become the primary method of evaluation of fetal wellbeing, and the relationship between the presence of fetal heart rate accelerations in response to fetal movement and subsequent good fetal outcome has been demonstrated. However, in areas where electronic monitors are few or not available it would be useful if such accelerations could be demonstrated using the Pinard stethoscope. A prospective study involving 200 women with a singleton pregnancy of more than 34 weeks gestation was performed at Harare Maternity Hospital, Harare, Zimbabwe, when a 6 min electronic trace using an external transducer was compared with simultaneously performed 6 min manual record using the Pinard stethoscope. The findings showed that the manual record has a sensitivity of 75% and although traces with excessive base line variability would show an acceleration on the manual record, in no case with a flat trace was an acceleration noted on the manual record. This acceptable degree of sensitivity would allow for a significant decrease in the number of women being referred for electronic tracing and would be a more appropriate use of limited resources in terms of manpower and equipment.

  16. Stethoscope versus point-of-care ultrasound in the differential diagnosis of dyspnea: a randomized trial.

    PubMed

    Özkan, Behzat; Ünlüer, Erden E; Akyol, Pinar Y; Karagöz, Arif; Bayata, Mehmet S; Akoğlu, Haldun; Oyar, Orhan; Dalli, Ayşe; Topal, Fatih E

    2015-12-01

    We aimed to determine the accuracies of point-of-care ultrasound (PoCUS) and stethoscopes as part of the physical examinations of patients with dyspnea. Three emergency medicine specialists in each of two groups of ultrasound and stethoscope performers underwent didactic and hands-on training on PoCUS and stethoscope usage. All the patients enrolled were randomized to one of two predetermined PoCUS or stethoscope groups. The diagnostic performance of ultrasonography was higher than that of the stethoscope in the diagnoses of heart failure (90 vs. 86%, 1.00 vs. 0.89, and 5.00 vs. 4.92, respectively) and pneumonia (90 vs. 86.7%, 0.75 vs. 0.73, and 16.50 vs. 13.82, respectively). No significant differences were observed in the utility parameters of these modalities in these diagnoses. Although some authors argue that it is time to abandon the 'archaic tools' of past centuries, we believe that it is too early to discontinue the use of the stethoscope.

  17. Smartphone attachment for stethoscope recording.

    PubMed

    Thompson, Jeff

    2015-01-01

    With the ubiquity of smartphones and the rising technology of 3D printing, novel devices can be developed that leverage the "computer in your pocket" and rapid prototyping technologies toward scientific, medical, engineering, and creative purposes. This paper describes such a device: a simple 3D-printed extension for Apple's iPhone that allows the sound from an off-the-shelf acoustic stethoscope to be recorded using the phone's built-in microphone. The attachment's digital 3D files can be easily shared, modified for similar phones and devices capable of recording audio, and in combination with 3D printing technology allow for fabrication of a durable device without need for an entire factory of expensive and specialized machining tools. It is hoped that by releasing this device as an open source set of printable files that can be downloaded and reproduced cheaply, others can make use of these developments where access to cost-prohibitive, specialized medical instruments are not available. Coupled with specialized smartphone software ("apps"), more sophisticated and automated diagnostics may also be possible on-site.

  18. 21 CFR 870.1875 - Stethoscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ...) Identification. A manual stethoscope is a mechanical device used to project the sounds associated with the heart... stethoscope is an electrically amplified device used to project the sounds associated with the heart, arteries...

  19. 21 CFR 870.1875 - Stethoscope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ...) Identification. A manual stethoscope is a mechanical device used to project the sounds associated with the heart... stethoscope is an electrically amplified device used to project the sounds associated with the heart, arteries...

  20. 21 CFR 870.1875 - Stethoscope.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ...) Identification. A manual stethoscope is a mechanical device used to project the sounds associated with the heart... stethoscope is an electrically amplified device used to project the sounds associated with the heart, arteries...

  1. 21 CFR 870.1875 - Stethoscope.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ...) Identification. A manual stethoscope is a mechanical device used to project the sounds associated with the heart... stethoscope is an electrically amplified device used to project the sounds associated with the heart, arteries...

  2. 21 CFR 870.1875 - Stethoscope.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ...) Identification. A manual stethoscope is a mechanical device used to project the sounds associated with the heart... stethoscope is an electrically amplified device used to project the sounds associated with the heart, arteries...

  3. Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized Hospital

    PubMed Central

    2013-01-01

    Introduction Hospital acquired infections are recognized as critical public health problems. Infections are frequently caused by organisms residing in healthcare environment, including contaminated medical equipment like Stethoscopes. Objective To determine bacterial contamination, bacterial profile and anti-microbial susceptibility pattern of the isolates from stethoscopes at Jimma University Specialized Hospital. Methodology Cross-sectional study conducted from May to September 2011 at Jimma University Specialized Hospital. One hundred seventy-six stethoscopes owned by Health Care Workers (HCWs) and Medical students were randomly selected and studied. Self-administered structured questionnaire was used to collect socio-demographic data. Specimen was collected using moisten sterile cotton swab and 1 ml normal saline was used to transport the specimen, all laboratory investigations were done following standard microbiological techniques, at Microbiology Laboratory, Jimma University. SPSS windows version 16 used for data analysis and P <0.05 was considered statistically significant. Result: A total, of 151 (85.8%) stethoscopes were contaminated. A total of 256 bacterial strains and a mean of 1.44×104 CFUs/diaphragm of stethoscopes was isolated. Of the 256 isolates, 133 (52%) were potential pathogens like S. aureus, Klebsiella spp., Citrobacter spp., Salmonella spp., Proteus spp., Enterobacter spp., P. aeruginosa and E. coli. All strains were resistant to multiple classes of antibiotics (two to eight classes of antibiotics). Disinfection practice was poor. Disinfection practice was found to be associated with bacterial contamination of stethoscopes (P < 0.05). High contamination rate 100 (90.9%) was observed among stethoscopes that had never been disinfected; while the least contamination 29 (72.2%) was found on those disinfected a week or less before the survey. Conclusion Bacterial contamination of the stethoscope was significant. The isolates were potential pathogens and resistant to multiple classes of antibiotics. Stethoscope is potential vehicle in the transmission of infections between patients and Healthcare Workers. Stethoscope diaphragm should be disinfected before and after each patient contact. PMID:24330702

  4. Bacterial contamination, bacterial profile and antimicrobial susceptibility pattern of isolates from stethoscopes at Jimma University Specialized Hospital.

    PubMed

    Shiferaw, Teklu; Beyene, Getenet; Kassa, Tesfaye; Sewunet, Tsegaye

    2013-12-13

    Hospital acquired infections are recognized as critical public health problems. Infections are frequently caused by organisms residing in healthcare environment, including contaminated medical equipment like Stethoscopes. To determine bacterial contamination, bacterial profile and anti-microbial susceptibility pattern of the isolates from stethoscopes at Jimma University Specialized Hospital. Cross-sectional study conducted from May to September 2011 at Jimma University Specialized Hospital. One hundred seventy-six stethoscopes owned by Health Care Workers (HCWs) and Medical students were randomly selected and studied. Self-administered structured questionnaire was used to collect socio-demographic data. Specimen was collected using moisten sterile cotton swab and 1 ml normal saline was used to transport the specimen, all laboratory investigations were done following standard microbiological techniques, at Microbiology Laboratory, Jimma University. SPSS windows version 16 used for data analysis and P <0.05 was considered statistically significant. A total, of 151 (85.8%) stethoscopes were contaminated. A total of 256 bacterial strains and a mean of 1.44×104 CFUs/diaphragm of stethoscopes was isolated. Of the 256 isolates, 133 (52%) were potential pathogens like S. aureus, Klebsiella spp., Citrobacter spp., Salmonella spp., Proteus spp., Enterobacter spp., P. aeruginosa and E. coli. All strains were resistant to multiple classes of antibiotics (two to eight classes of antibiotics). Disinfection practice was poor. Disinfection practice was found to be associated with bacterial contamination of stethoscopes (P < 0.05). High contamination rate 100 (90.9%) was observed among stethoscopes that had never been disinfected; while the least contamination 29 (72.2%) was found on those disinfected a week or less before the survey. Bacterial contamination of the stethoscope was significant. The isolates were potential pathogens and resistant to multiple classes of antibiotics. Stethoscope is potential vehicle in the transmission of infections between patients and Healthcare Workers. Stethoscope diaphragm should be disinfected before and after each patient contact.

  5. 21 CFR 884.2900 - Fetal stethoscope.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Fetal stethoscope. (a) Identification. A fetal stethoscope is a device used for listening to fetal heart sounds. It is designed to transmit the fetal heart sounds not only through sound channels by air...

  6. 21 CFR 884.2900 - Fetal stethoscope.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Fetal stethoscope. (a) Identification. A fetal stethoscope is a device used for listening to fetal heart sounds. It is designed to transmit the fetal heart sounds not only through sound channels by air...

  7. 21 CFR 884.2900 - Fetal stethoscope.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... Fetal stethoscope. (a) Identification. A fetal stethoscope is a device used for listening to fetal heart sounds. It is designed to transmit the fetal heart sounds not only through sound channels by air...

  8. 21 CFR 884.2900 - Fetal stethoscope.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... Fetal stethoscope. (a) Identification. A fetal stethoscope is a device used for listening to fetal heart sounds. It is designed to transmit the fetal heart sounds not only through sound channels by air...

  9. 21 CFR 884.2900 - Fetal stethoscope.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... Fetal stethoscope. (a) Identification. A fetal stethoscope is a device used for listening to fetal heart sounds. It is designed to transmit the fetal heart sounds not only through sound channels by air...

  10. The stethoscope: some preliminary investigations.

    PubMed

    Welsby, P D; Parry, G; Smith, D

    2003-12-01

    Textbooks, clinicians, and medical teachers differ as to whether the stethoscope bell or diaphragm should be used for auscultating respiratory sounds at the chest wall. Logic and our results suggest that stethoscope diaphragms are more appropriate.

  11. Bacterial contamination and stethoscope disinfection practices: a cross-sectional survey of healthcare workers in Karachi, Pakistan.

    PubMed

    Rao, Danish Ahmed; Aman, Aiysha; Muhammad Mubeen, Syed; Shah, Ahmed

    2017-07-01

    Stethoscopes routinely used for clinical examination of patients may potentially transfer micro-organisms and cause iatrogenic infections. This study was undertaken to detect the presence of microorganisms on stethoscopes used clinically in hospitals of Karachi, Pakistan and to ascertain the infection control practices of healthcare workers (HCWs). In a cross-sectional study, 118 samples were collected from public and private institutions. Samples were tested for the presence and sensitivity of pathogenic microorganisms. Microorganisms were found on diaphragms of 33/64 (51.6%) and 19/57 (33.3%) stethoscopes in public and private sector hospitals, respectively. Methycillin resistance was identified in all staphylococcally contaminated samples. Only 33 (18%) respondents reported cleaning their stethoscopes regularly. We highlight the need for more and better on-the-job routines for decontaminating stethoscopes among HCWs in Karachi.

  12. Nursing Care Hour Standards Study. Part 2 thru Part 4

    DTIC Science & Technology

    1981-09-01

    pulse area and record results. PULSE - APICAL: Place equipment at bedside, place stethoscope over .5 apex of heart and count rate, remove stethoscope ...equipment at bedside, assist physi- 2 cian with measurement, then remove equipment from area, HEART SOUNDS ASSESSMENT: Place stethoscope at bedside...Remove fingers from pulse area and record results. OR PULSE - APICAL: Place equipment at bedside, place stethoscope over apex of heart and count rate

  13. The stethoscope: some preliminary investigations

    PubMed Central

    Welsby, P; Parry, G; Smith, D

    2003-01-01

    Textbooks, clinicians, and medical teachers differ as to whether the stethoscope bell or diaphragm should be used for auscultating respiratory sounds at the chest wall. Logic and our results suggest that stethoscope diaphragms are more appropriate. PMID:14707247

  14. Sensor system for heart sound biomonitor

    NASA Astrophysics Data System (ADS)

    Maple, Jarrad L.; Hall, Leonard T.; Agzarian, John; Abbott, Derek

    1999-09-01

    Heart sounds can be utilized more efficiently by medical doctors when they are displayed visually, rather than through a conventional stethoscope. A system whereby a digital stethoscope interfaces directly to a PC will be directly along with signal processing algorithms, adopted. The sensor is based on a noise cancellation microphone, with a 450 Hz bandwidth and is sampled at 2250 samples/sec with 12-bit resolution. Further to this, we discuss for comparison a piezo-based sensor with a 1 kHz bandwidth. A major problem is that the recording of the heart sound into these devices is subject to unwanted background noise which can override the heart sound and results in a poor visual representation. This noise originates from various sources such as skin contact with the stethoscope diaphragm, lung sounds, and other surrounding sounds such as speech. Furthermore we demonstrate a solution using 'wavelet denoising'. The wavelet transform is used because of the similarity between the shape of wavelets and the time-domain shape of a heartbeat sound. Thus coding of the waveform into the wavelet domain is achieved with relatively few wavelet coefficients, in contrast to the many Fourier components that would result from conventional decomposition. We show that the background noise can be dramatically reduced by a thresholding operation in the wavelet domain. The principle is that the background noise codes into many small broadband wavelet coefficients that can be removed without significant degradation of the signal of interest.

  15. Prevalence of methicillin-resistant Staphylococcus aureus on the stethoscopes of emergency medical services providers.

    PubMed

    Merlin, Mark A; Wong, Matthew L; Pryor, Peter W; Rynn, Kevin; Marques-Baptista, Andreia; Perritt, Rachael; Stanescu, Catherine G; Fallon, Timothy

    2009-01-01

    The investigation seeks to determine the prevalence of methicillin-resistant Staphylococcus aureus (MRSA) on the stethoscopes of emergency medical services (EMS) providers. While stethoscopes are known fomites for MRSA, the prevalence of MRSA in the prehospital setting is not well documented in the literature. This was a prospective, observational cohort study of 50 stethoscopes provided by consecutive, consenting EMS providers at our academic emergency department (ED). Stethoscopes were swabbed with saline culture applicators and samples were cultured on a commercial MRSA test kit containing mannitol salt agar with oxacillin. After 72 hours of incubation at 37 degrees C, two emergency physicians and one microbiologist analyzed the plates independently. MRSA colonization was recorded as positive if all three reviewers agreed that colonization had occurred. Of 50 stethoscopes, 16 had MRSA colonization, and 16 (32%) EMS professionals had no recollection of when their stethoscopes had been cleaned last. Reported length of time since last cleaning was grouped into six categories: one to seven days, eight to 14 days, 15 to 30 days, 31 to 180 days, 181 days to 365 days, and unknown. The median time frame reported since the last cleaning was one to seven days. In the model, an increase from one time category to the next increased the odds of MRSA colonization by 1.86 (odds ratio = 1.86, p = 0.038). In this ED setting, MRSA was found on approximately one in three stethoscopes of EMS professionals. A longer length of time since the last stethoscope cleaning increased the odds of MRSA colonization.

  16. Music-of-light stethoscope: a demonstration of the photoacoustic effect

    NASA Astrophysics Data System (ADS)

    Nikitichev, D. I.; Xia, W.; Hill, E.; Mosse, C. A.; Perkins, T.; Konyn, K.; Ourselin, S.; Desjardins, A. E.; Vercauteren, T.

    2016-07-01

    In this paper we present a system aimed at demonstrating the photoacoustic (PA) effect for educational purposes. PA imaging is a hybrid imaging modality that requires no contrast agent and has a great potential for spine and brain lesion characterisation, breast cancer and blood flow monitoring notably in the context of fetal surgery. It relies on combining light excitation with ultrasound reception. Our brief was to present and explain PA imaging in a public-friendly way suitable for a variety of ages and backgrounds. We developed a simple, accessible demonstration unit using readily available materials. We used a modulated light emitting diode (LED) torch and an electronic stethoscope. The output of a music player was used for light modulation and the chest piece of the stethoscope covered by a black tape was used as an absorbing target and an enclosed chamber. This demonstration unit was presented to the public at the Bloomsbury Festival On Light in October 2015. Our stall was visited by over 100 people of varying ages. Twenty families returned in-depth evaluation questionnaires, which show that our explanations of the photoacoustic effect were well understood. Their interest in biomedical engineering was increased.

  17. Music-of-light stethoscope: a demonstration of the photoacoustic effect

    PubMed Central

    Nikitichev, D I; Xia, W; Hill, E; Mosse, C A; Perkins, T; Konyn, K; Ourselin, S; Desjardins, A E; Vercauteren, T

    2016-01-01

    Abstract In this paper we present a system aimed at demonstrating the photoacoustic (PA) effect for educational purposes. PA imaging is a hybrid imaging modality that requires no contrast agent and has a great potential for spine and brain lesion characterisation, breast cancer and blood flow monitoring notably in the context of fetal surgery. It relies on combining light excitation with ultrasound reception. Our brief was to present and explain PA imaging in a public-friendly way suitable for a variety of ages and backgrounds. We developed a simple, accessible demonstration unit using readily available materials. We used a modulated light emitting diode (LED) torch and an electronic stethoscope. The output of a music player was used for light modulation and the chest piece of the stethoscope covered by a black tape was used as an absorbing target and an enclosed chamber. This demonstration unit was presented to the public at the Bloomsbury Festival On Light in October 2015. Our stall was visited by over 100 people of varying ages. Twenty families returned in-depth evaluation questionnaires, which show that our explanations of the photoacoustic effect were well understood. Their interest in biomedical engineering was increased. PMID:29249838

  18. Music-of-light stethoscope: a demonstration of the photoacoustic effect.

    PubMed

    Nikitichev, D I; Xia, W; Hill, E; Mosse, C A; Perkins, T; Konyn, K; Ourselin, S; Desjardins, A E; Vercauteren, T

    2016-07-01

    In this paper we present a system aimed at demonstrating the photoacoustic (PA) effect for educational purposes. PA imaging is a hybrid imaging modality that requires no contrast agent and has a great potential for spine and brain lesion characterisation, breast cancer and blood flow monitoring notably in the context of fetal surgery. It relies on combining light excitation with ultrasound reception. Our brief was to present and explain PA imaging in a public-friendly way suitable for a variety of ages and backgrounds. We developed a simple, accessible demonstration unit using readily available materials. We used a modulated light emitting diode (LED) torch and an electronic stethoscope. The output of a music player was used for light modulation and the chest piece of the stethoscope covered by a black tape was used as an absorbing target and an enclosed chamber. This demonstration unit was presented to the public at the Bloomsbury Festival On Light in October 2015. Our stall was visited by over 100 people of varying ages. Twenty families returned in-depth evaluation questionnaires, which show that our explanations of the photoacoustic effect were well understood. Their interest in biomedical engineering was increased.

  19. Clinical Assessment of the Noise Immune Stethoscope aboard a U.S. Navy Carrier

    DTIC Science & Technology

    2011-11-01

    Participants rated their confidence in the use of this device to detect heart /lung sounds compared to a traditional stethoscope . A Wilcoxin rank...Figure 15. Median ratings of confidence in the use of the device to detect pathologic heart /lung sounds compared to a traditional stethoscope in...intubation versus heart /lung sounds; figure 16). To assess the ease of use compared to a traditional stethoscope , one-sample Wilcoxin signed rank tests

  20. Ultrasound and stethoscope as tools in medical education and practice: considerations for the archives

    PubMed Central

    Fakoya, Francis A; du Plessis, Maira; Gbenimacho, Ikechi B

    2016-01-01

    Objectives In recent years, the use and portability of ultrasound has threatened the utility of the stethoscope, with many debating and even advocating its replacement. The authors set out to assess opinions in this regard among faculty within a medical school and specifically within an anatomy department where ultrasound is incorporated into the curriculum from the first term. Methods A debate was elicited during a biweekly Anatomy Journal Club session and was centered on three published papers presented. Several questions were raised regarding the possible replacement of stethoscope – the value of early exposure to students as well as how ultrasound and stethoscope should be considered by physicians, students, and teachers. Results The general consensus was that the stethoscope should not be replaced but should be used in conjunction with emerging portable ultrasound. Caution was given that technology could “overcomplicate” diagnosis and lead to increased tests resulting in increased cost of care. In terms of exposing students to ultrasound, just as the stethoscope requires practice to use effectively, so does the ultrasound and should be introduced as early on as possible. As is the case with the stethoscope, students may not initially appreciate all the finer details on ultrasound; however, continual use would improve skill. Conclusion The stethoscope should always remain part of the physical examination and ultrasound should be used in addition to, not replacement of. As technology advances the need for apprenticeship, training increases and students of the medical profession should be exposed to these technologies as early as possible. Hence, it is not yet time to archive the stethoscope. Perhaps never. PMID:27471420

  1. Factors influencing stethoscope cleanliness among clinical medical students.

    PubMed

    Saunders, C; Hryhorskyj, L; Skinner, J

    2013-07-01

    This study aims to identify current stethoscope hygiene habits and attitudes in a UK medical school setting. Students completed a questionnaire using Likert-scale questions and free-text answers. A total of 308 questionnaires were completed from a potential 750 students (41%); 22.4% of respondents had never cleaned their stethoscope and only 3.9% cleaned their stethoscope after every patient. Significant correlations were identified between cleaning frequency and: others acting as role models (P = 0.001), students having confidence in how to clean stethoscopes (P = 0.001), and students thinking cleaning was important (P = 0.01), thereby highlighting inadequate education and role models as potential problems. Copyright © 2013 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  2. A Managed Care Model for the Military Departments

    DTIC Science & Technology

    1990-05-15

    Seattle reports that a widely used technique for electronic monitoring of a fetal heart during delivery is "no more effective than a stethoscope in 6...detecting fetal distress."𔃿 The study director went on to say that obstetricians will probably continue to use the technique to avoid possible

  3. What's growing on General Practitioner's stethoscope?

    PubMed

    Carducci, A; Cargnelutti, M; Tassinari, F; Bizzarro, A; Cordio, G; Carletti, S; Maccarini, L; Pelissero, G

    2016-01-01

    Non-critical medical devices, as stethoscopes, have long been considered as vectors in microorganisms' transmission. Cleaning standards for non-critical medical equipment are often unclear. This study was designed to assess the attitude of General Practitioners (GPs) towards cleaning their stethoscope and the degree of microbiological contamination of doctor's instrument in outpatient setting. Observational, crossover study. A structured questionnaire was administered to GPs to test their knowledge about medical instrument's cleanliness recommendations and the surface of the diaphragm of their stethoscopes was analyzed for bacteriological isolates using mass spectrometry technique. Most of GPs declared they don't know cleaning recommendations for non-critical medical devices and a relevant bacterial growth was identified on the majority of the stethoscopes' membranes. Almost all microbiological isolates resulted typically found in cutaneous flora. We can't state that the GP's stethoscopes feature a risk of transmission for microbiological pathogens; anyway, because of the level of contamination we observed, cleaning recommendations to disinfect instruments on a regular basis should be better indicated.

  4. Stethoscopes as a source of hospital-acquired methicillin-resistant Staphylococcus aureus.

    PubMed

    Russell, Abigail; Secrest, Janet; Schreeder, Carolyn

    2012-04-01

    Stethoscopes are potential vectors of methicillin-resistant Staphylococcus aureus (MRSA). The purpose of this project was to determine the presence of MRSA on the diaphragms of personal and unit stethoscopes within a hospital setting before and after cleaning with alcohol prep pads. The sample consisted of 141 personal and unit stethoscopes in adult medical-surgical and intensive care units of a large university hospital in the Southeast. Each stethoscope was cultured once before cleaning and once after cleaning. Cultures were obtained using sterile swabs and inoculated on a selective medium for MRSA. Bacterial growth was noted in the precleaning group, but no MRSA colonies were detected. The postcleaning group had no bacterial growth. There was not enough data to statistically support that isopropyl alcohol is effective in decreasing bacterial counts; however, these findings suggest that current disinfection guidelines are effective in preventing MRSA colonization on stethoscopes in this setting. Copyright © 2012 American Society of PeriAnesthesia Nurses. Published by Elsevier Inc. All rights reserved.

  5. Tele-auscultation support system with mixed reality navigation.

    PubMed

    Hori, Kenta; Uchida, Yusuke; Kan, Tsukasa; Minami, Maya; Naito, Chisako; Kuroda, Tomohiro; Takahashi, Hideya; Ando, Masahiko; Kawamura, Takashi; Kume, Naoto; Okamoto, Kazuya; Takemura, Tadamasa; Yoshihara, Hiroyuki

    2013-01-01

    The aim of this research is to develop an information support system for tele-auscultation. In auscultation, a doctor requires to understand condition of applying a stethoscope, in addition to auscultatory sounds. The proposed system includes intuitive navigation system of stethoscope operation, in addition to conventional audio streaming system of auscultatory sounds and conventional video conferencing system for telecommunication. Mixed reality technology is applied for intuitive navigation of the stethoscope. Information, such as position, contact condition and breath, is overlaid on a view of the patient's chest. The contact condition of the stethoscope is measured by e-textile contact sensors. The breath is measured by a band type breath sensor. In a simulated tele-auscultation experiment, the stethoscope with the contact sensors and the breath sensor were evaluated. The results show that the presentation of the contact condition was not understandable enough for navigating the stethoscope handling. The time series of the breath phases was usable for the remote doctor to understand the breath condition of the patient.

  6. Predictors of stethoscope disinfection among pediatric health care providers.

    PubMed

    Muniz, Jeanette; Sethi, Rosh K V; Zaghi, Justin; Ziniel, Sonja I; Sandora, Thomas J

    2012-12-01

    Stethoscopes are contaminated with bacteria, but predictors of stethoscope disinfection frequency are unknown. We sought to describe health care provider stethoscope disinfection attitudes and practices and determine predictors of frequent disinfection. We used an anonymous online survey of nurses, nurse practitioners, and physicians at a pediatric hospital. We assessed frequency and methods of disinfection, perceptions of contamination, and barriers to disinfection. Multivariate logistic regression models were used to identify independent predictors of disinfecting after every use. One thousand four hundred one respondents completed the survey: 76% believed that infection transmission occurs via stethoscopes, but only 24% reported disinfecting after every use. In multivariate analyses, belief that infection transmission occurs via stethoscopes significantly increased the odds of disinfection after every use (odds ratio [OR], 2.06 [95% confidence interval (CI): 1.38-3.06]). The odds of disinfection after every use were significantly decreased in those who perceived the following barriers: lack of time (OR, 0.31 [95% CI: 0.18-0.54]), lack of access to disinfection material (OR, 0.41 [95% CI: 0.29-0.57]), or lack of visual reminders to disinfect (OR, 0.22 [95% CI: 0.14-0.34]). Only a minority of pediatric health care providers reported disinfecting their stethoscopes after every use. Increasing access to disinfection materials and visual reminders in health care facilities may improve stethoscope disinfection practices. Copyright © 2012 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  7. Stethoscopes as potential intrahospital carriers of pathogenic microorganisms.

    PubMed

    Campos-Murguía, Alejandro; León-Lara, Ximena; Muñoz, Juan M; Macías, Alejandro E; Alvarez, José A

    2014-01-01

    Stethoscopes can take part in the transmission of health care-associated infections. We cultured 112 stethoscopes by direct imprint on blood agar to estimate the prevalence of potentially pathogenic microorganisms. Forty-eight (47%) produced 50 potentially pathogenic microorganisms; from these, 43 (86%) were Staphylococcus aureus, of which 18 (42%) were methicillin-resistant S. aureus. We concluded that stethoscopes should be considered as potential fomites and must be disinfected routinely before and after each patient contact. Copyright © 2014 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  8. Bacterial contamination of stethoscope chest pieces and the effect of daily cleaning.

    PubMed

    Fujita, H; Hansen, B; Hanel, R

    2013-01-01

    Stethoscopes are a potential source of nosocomial infection for hospitalized humans, a phenomenon not previously studied in companion animals. To determine if daily cleaning of stethoscope chest pieces reduces bacterial contamination between cleanings. Client-owned dogs and cats. Prospective observational study. In phase 1, bacterial cultures were obtained from the chest pieces of 10 participant stethoscopes once weekly for 3 weeks. In phase 2, stethoscopes were cleaned daily and 2 culture samples were obtained once weekly, immediately before and after cleaning with 70% isopropyl alcohol, for 3 weeks. Daily cleaning eliminated bacteria immediately after each cleaning (P = .004), but did not reduce the rate of positive cultures obtained before cleaning in phase 2. Cultures were positive for 20/30 (67%) samples during phase 1 and 18/30 (60%) obtained before daily cleaning during phase 2. Recovered organisms included normal skin flora, agents of opportunistic infections, and potential pathogens. The only genus that was repeatedly recovered from the same stethoscope for 2 or more consecutive weeks was Bacillus sp. Daily cleaning was highly effective at removing bacteria, but provided no reduction in precleaning contamination. Cleaning stethoscopes after use on dogs or cats infected with pathogenic bacteria and before use on immunocompromised animals should be considered. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  9. Are Simulation Stethoscopes a Useful Adjunct for Emergency Residents' Training on High-fidelity Mannequins?

    PubMed

    Warrington, Steven J; Beeson, Michael S; Fire, Frank L

    2013-05-01

    Emergency medicine residents use simulation training for many reasons, such as gaining experience with critically ill patients and becoming familiar with disease processes. Residents frequently criticize simulation training using current high-fidelity mannequins due to the poor quality of physical exam findings present, such as auscultatory findings, as it may lead them down an alternate diagnostic or therapeutic pathway. Recently wireless remote programmed stethoscopes (simulation stethoscopes) have been developed that allow wireless transmission of any sound to a stethoscope receiver, which improves the fidelity of a physical examination and the simulation case. Following institutional review committee approval, 14 PGY1-3 emergency medicine residents were assessed during 2 simulation-based cases using pre-defined scoring anchors on multiple actions, such as communication skills and treatment decisions (Appendix 1). Each case involved a patient presenting with dyspnea requiring management based off physical examination findings. One case was a patient with exacerbation of heart failure, while the other was a patient with a tension pneumothorax. Each resident was randomized into a case associated with the simulation stethoscope. Following the cases residents were asked to fill out an evaluation questionnaire. Residents perceived the most realistic physical exam findings on those associated with the case using the simulation stethoscope (13/14, 93%). Residents also preferred the simulation stethoscope as an adjunct to the case (13/14, 93%), and they rated the simulation stethoscope case to have significantly more realistic auscultatory findings (4.4/5 vs. 3.0/5 difference of means 1.4, p=0.0007). Average scores of residents were significantly better in the simulation stethoscope-associated case (2.5/3 vs. 2.3/3 difference of means 0.2, p=0.04). There was no considerable difference in the total time taken per case. A simulation stethoscope may be a useful adjunct to current emergency medicine simulation-based training. Residents both preferred the use of the simulation stethoscope and perceived physical exam findings to be more realistic, leading to improved fidelity. Potential sources of bias include the small population, narrow scoring range, and the lack of blinding. Further research, focusing on use for resident assessment and clinical significance with a larger population and blinding of graders, is needed.

  10. Are Simulation Stethoscopes a Useful Adjunct for Emergency Residents' Training on High-fidelity Mannequins?

    PubMed Central

    Beeson, Michael S.; Fire, Frank L.

    2013-01-01

    Introduction: Emergency medicine residents use simulation training for many reasons, such as gaining experience with critically ill patients and becoming familiar with disease processes. Residents frequently criticize simulation training using current high-fidelity mannequins due to the poor quality of physical exam findings present, such as auscultatory findings, as it may lead them down an alternate diagnostic or therapeutic pathway. Recently wireless remote programmed stethoscopes (simulation stethoscopes) have been developed that allow wireless transmission of any sound to a stethoscope receiver, which improves the fidelity of a physical examination and the simulation case. Methods: Following institutional review committee approval, 14 PGY1-3 emergency medicine residents were assessed during 2 simulation-based cases using pre-defined scoring anchors on multiple actions, such as communication skills and treatment decisions (Appendix 1). Each case involved a patient presenting with dyspnea requiring management based off physical examination findings. One case was a patient with exacerbation of heart failure, while the other was a patient with a tension pneumothorax. Each resident was randomized into a case associated with the simulation stethoscope. Following the cases residents were asked to fill out an evaluation questionnaire. Results: Residents perceived the most realistic physical exam findings on those associated with the case using the simulation stethoscope (13/14, 93%). Residents also preferred the simulation stethoscope as an adjunct to the case (13/14, 93%), and they rated the simulation stethoscope case to have significantly more realistic auscultatory findings (4.4/5 vs. 3.0/5 difference of means 1.4, p=0.0007). Average scores of residents were significantly better in the simulation stethoscope-associated case (2.5/3 vs. 2.3/3 difference of means 0.2, p=0.04). There was no considerable difference in the total time taken per case. Conclusion: A simulation stethoscope may be a useful adjunct to current emergency medicine simulation-based training. Residents both preferred the use of the simulation stethoscope and perceived physical exam findings to be more realistic, leading to improved fidelity. Potential sources of bias include the small population, narrow scoring range, and the lack of blinding. Further research, focusing on use for resident assessment and clinical significance with a larger population and blinding of graders, is needed. PMID:23687548

  11. Technology for enhancing chest auscultation in clinical simulation.

    PubMed

    Ward, Jeffrey J; Wattier, Bryan A

    2011-06-01

    The ability to use an acoustic stethoscope to detect lung and/or heart sounds, and then to then communicate one's interpretation of those sounds is an essential skill for many medical professionals. Interpretation of lung and heart sounds, in the context of history and other examination findings, often aids the differential diagnosis. Bedside assessment of changing auscultation findings may also guide treatment. Learning lung and heart auscultation skills typically involves listening to pre-recorded normal and adventitious sounds, often followed by laboratory instruction to guide stethoscope placement, and finally correlating the sounds with the associated pathophysiology and pathology. Recently, medical simulation has become an important tool for teaching prior to clinical practice, and for evaluating bedside auscultation skills. When simulating cardiovascular or pulmonary problems, high-quality lung and heart sounds should be able to accurately corroborate other findings such as vital signs, arterial blood gas values, or imaging. Digital audio technology, the Internet, and high-fidelity simulators have increased opportunities for educators and learners. We review the application of these technologies and describe options for reproducing lung and heart sounds, as well as their advantages and potential limitations.

  12. Antimicrobial copper alloys decreased bacteria on stethoscope surfaces.

    PubMed

    Schmidt, Michael G; Tuuri, Rachel E; Dharsee, Arif; Attaway, Hubert H; Fairey, Sarah E; Borg, Keith T; Salgado, Cassandra D; Hirsch, Bruce E

    2017-06-01

    Stethoscopes may serve as vehicles for transmission of bacteria among patients. The aim of this study was to assess the efficacy of antimicrobial copper surfaces to reduce the bacterial concentration associated with stethoscope surfaces. A structured prospective trial involving 21 health care providers was conducted at a pediatric emergency division (ED) (n = 14) and an adult medical intensive care unit located in tertiary care facilities (n = 7). Four surfaces common to a stethoscope and a facsimile instrument fabricated from U.S. Environmental Protection Agency-registered antimicrobial copper alloys (AMCus) were assessed for total aerobic colony counts (ACCs), methicillin-resistant Staphylococcus aureus, gram-negative bacteria, and vancomycin-resistant enterococci for 90 days. The mean ACCs collectively recovered from all stethoscope surfaces fabricated from the AMCus were found to carry significantly lower concentrations of bacteria (pediatric ED, 11.7 vs 127.1 colony forming units [CFU]/cm 2 , P < .00001) than their control equivalents. This observation was independent of health care provider or infection control practices. Absence of recovery of bacteria from the AMCu surfaces (66.3%) was significantly higher (P < .00001) than the control surfaces (22.4%). The urethane rim common to the stethoscopes was the most heavily burdened surface; mean concentrations exceeded the health care-associated infection acquisition concentration (5 CFU/cm 2 ) by at least 25×, supporting that the stethoscope warrants consideration in plans mitigating microbial cross-transmission during patient care. Stethoscope surfaces fabricated with AMCus were consistently found to harbor fewer bacteria. Copyright © 2017 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  13. Comparing the auscultatory accuracy of health care professionals using three different brands of stethoscopes on a simulator

    PubMed Central

    Mehmood, Mansoor; Abu Grara, Hazem L; Stewart, Joshua S; Khasawneh, Faisal A

    2014-01-01

    Background It is considered standard practice to use disposable or patient-dedicated stethoscopes to prevent cross-contamination between patients in contact precautions and others in their vicinity. The literature offers very little information regarding the quality of currently used stethoscopes. This study assessed the fidelity with which acoustics were perceived by a broad range of health care professionals using three brands of stethoscopes. Methods This prospective study used a simulation center and volunteer health care professionals to test the sound quality offered by three brands of commonly used stethoscopes. The volunteer’s proficiency in identifying five basic ausculatory sounds (wheezing, stridor, crackles, holosystolic murmur, and hyperdynamic bowel sounds) was tested, as well. Results A total of 84 health care professionals (ten attending physicians, 35 resident physicians, and 39 intensive care unit [ICU] nurses) participated in the study. The higher-end stethoscope was more reliable than lower-end stethoscopes in facilitating the diagnosis of the auscultatory sounds, especially stridor and crackles. Our volunteers detected all tested sounds correctly in about 69% of cases. As expected, attending physicians performed the best, followed by resident physicians and subsequently ICU nurses. Neither years of experience nor background noise seemed to affect performance. Postgraduate training continues to offer very little to improve our trainees’ auscultation skills. Conclusion The results of this study indicate that using low-end stethoscopes to care for patients in contact precautions could compromise identifying important auscultatory findings. Furthermore, there continues to be an opportunity to improve our physicians and ICU nurses’ auscultation skills. PMID:25152636

  14. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    PubMed

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p < 0.0001. The stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  15. Portable system for auscultation and lung sound analysis.

    PubMed

    Nabiev, Rustam; Glazova, Anna; Olyinik, Valery; Makarenkova, Anastasiia; Makarenkov, Anatolii; Rakhimov, Abdulvosid; Felländer-Tsai, Li

    2014-01-01

    A portable system for auscultation and lung sound analysis has been developed, including the original electronic stethoscope coupled with mobile devices and special algorithms for the automated analysis of pulmonary sound signals. It's planned that the developed system will be used for monitoring of health status of patients with various pulmonary diseases.

  16. Aerobic Bacteria in the Diaphragmatic Portion of Stethoscope of Medical Professionals of Tertiary Care Hospital.

    PubMed

    Bham, G; Bhandari, J; Neupane, M R; Dawadi, R; Pradhan, P

    2015-01-01

    Hospital environment is a reservoir of wide varieties of microorganisms which are frequently reported colonizing in medical equipment. Stethoscopes are essential tools and of universal use in the medical profession, which might be a source of spreading nosocomial infections. This research project was conducted with an aim to assess the presence of aerobic bacteria in the stethoscope of the medical doctors working at Patan Hospital and students of Patan Academy of Health Sciences. It is a cross sectional study based on structured questionnaire and sample assessment from the stethoscope of doctors and students of Patan Hospital and Patan Academy of Health Sciences. The stethescopes used by the doctors of five major departments of Patan Hospital and students of clinical years were included in this study. Total of 99 stethoscope owned by different level of professionals (positions) and different departments were examined for bacterial contamination. Out of them, 36 were found to be considerably contaminated. Single strain of bacteria was grown from a single stethoscope. Among them 34 were Gram positive and remaining were Gram negative. Out of 34 gram postive bacteria, 29 were identified as Staphylococcus aureus, six were identified as Coagulase Negative Staphylococcus and remaining were Gram positive bacilli. There is presence of aerobic bacteria in diaphragmatic portion of stethoscope of medical professional of which the gram positives were the commonest.

  17. The stethoscope in the Emergency Department: a vector of infection?

    PubMed Central

    Núñez, S.; Moreno, A.; Green, K.; Villar, J.

    2000-01-01

    The purposes of this study were to determine whether microorganisms can be isolated from the membranes of stethoscopes used by clinicians and nurses, and to analyse whether or not the degree of bacterial colonization could be reduced with different cleaning methods. We designed a transversal before-after study in which 122 stethoscopes were examined. Coagulase negative staphylococci (which are also potentially pathogenic microorganisms) were isolated together with 13 other potentially pathogenic microorganisms, including S. aureus, Acinetobacter sp. and Enterobacter agglomerans. The most effective antiseptic was propyl alcohol. Analysis of the cleaning habits of the Emergency Department (ED) staff, showed that 45% cleaned the stethoscope annually or never. The isolation of potentially pathogenic microorganisms suggests that the stethoscope must be considered as a potential vector of infection not only in the ED but also in other hospital wards and out-patient clinics. PMID:10813148

  18. Validation of an effective, low cost, Free/open access 3D-printed stethoscope

    PubMed Central

    Pavlosky, Alexander; Glauche, Jennifer; Chambers, Spencer; Al-Alawi, Mahmoud; Yanev, Kliment

    2018-01-01

    The modern acoustic stethoscope is a useful clinical tool used to detect subtle, pathological changes in cardiac, pulmonary and vascular sounds. Currently, brand-name stethoscopes are expensive despite limited innovations in design or fabrication in recent decades. Consequently, the high cost of high quality, brand name models serves as a barrier to clinicians practicing in various settings, especially in low- and middle-income countries. In this publication, we describe the design and validation of a low-cost open-access (Free/Libre) 3D-printed stethoscope which is comparable to the Littmann Cardiology III for use in low-access clinics. PMID:29538426

  19. Vibro-acoustic model of a piezoelectric-based stethoscope for chest sound measurements

    NASA Astrophysics Data System (ADS)

    Nelson, G.; Rajamani, R.; Erdman, A.

    2015-09-01

    This article focuses on the influence of noise and vibration on chest sound measurements with a piezoelectric stethoscope. Two types of vibrations, namely inputs through the patient chest and disturbances from the physician, influence the acoustic measurement. The goal of this work is to develop a model to understand the propagation of these vibrational noises through the stethoscope and to the piezoelectric sensing element. Using the model, methods to reduce the influence of disturbances acting on the stethoscope from the physician handling the device are explored. A multi-DOF rigid body vibration model consisting of discrete connected components is developed for the piezoelectric stethoscope. Using a two-port lumped parameter model, the mechanical vibrations are related to the resulting electrical signal. The parameterized state space model is experimentally validated and its parameters are identified by using a thorax simulator and vibration shaker. Based on predictions from the model, the introduction of vibration isolation to reduce the influence of physician noise on the transducer is then pursued. It is shown that direct vibration isolation between the transducer and the rest of the stethoscope structure leads to a reduction in coupling with the patient’s chest. However, if isolation is instead introduced between the transducer housing and the rest of the stethoscope, then vibration isolation from the physician is achieved with far less reduction in patient coupling. Experimental results are presented to study the influence of the proposed design changes and confirm the predicted model behavior.

  20. A new UV-LED device for automatic disinfection of stethoscope membranes.

    PubMed

    Messina, Gabriele; Burgassi, Sandra; Messina, Daniele; Montagnani, Valerio; Cevenini, Gabriele

    2015-10-01

    Stethoscopes are widely used by doctors and nurses. Poor stethoscope hygiene is a potential source of nosocomial infection. This study aimed to propose an innovative solution, based on the latest advances in ultraviolet (UV) light-emitting diodes (LEDs), for disinfecting stethoscope membranes automatically and efficiently. Staphylococcus aureus, Escherichia coli, Pseudomonas aeruginosa, and Enterococcus faecalis were sown on 28 stethoscope membranes and then transferred to Petri dishes. Treatment involved illuminating exposed Petri dishes with a UVC LED for 1 minute. For each microbe, the number of colony-forming units (cfu) at 36°C was compared in control and treated dishes using the Wilcoxon signed-rank test. The Kruskal-Wallis test was used to assess percent reductions in bacteria. Statistical significance was set at 99%. A significant reduction in cfu counts after UV treatment (P < .01) was found for all bacteria: 85.5% for E faecalis, 87.5% for S aureus, 94.3% for E coli, and 94.9% for P aeruginosa . No significant differences in percent reduction in cfu were found between bacteria (P > .01). The stethoscope, symbol of medicine and health care professionals, has been demonstrated to be a carrier of microorganisms. The treatment technique was effective and efficient in disinfecting the membranes. These promising results represent a step forward toward eliminating stethoscope membrane contamination with an innovative approach. Copyright © 2015 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  1. A Dual-Mode Noise-Immune Stethoscope for Use in Noisy Vehicles

    DTIC Science & Technology

    2006-11-01

    inside helicopters, fixed-wing aircraft, or ambulances where noise levels preclude auscultation with standard stethoscopes. With- out this...The use of an ultrasound transmitter and receiver, however, provides an essentially noise-free auscultation channel since transportation vehicles do...broadband noise fields of intensities as high as 120 dB. A hybrid stethoscope has been developed that allows auscultation by ultrasound Doppler as well

  2. Assessment of the Noise Immune Stethoscope in a Clinical Environment

    DTIC Science & Technology

    2014-03-01

    compared to using a traditional stethoscope . Anecdotal feedback from the clinicians indicated that sounds from the heart and related cardiothoracic...same technology as widely available fetal heart rate monitors for the consumer market. Comparable to other devices that combine acoustic and Doppler...understand Doppler” Congestive heart failure “able to hear crackles” Aortic stenosis “similar to traditional stethoscope , able to hear flows across

  3. A New Stethoscope Design with Unique Characteristics and Development in Medical Device.

    PubMed

    Ghahramanifar, M; Haghani, M; Ghadimi Moghadam, A; Ghadimi Moghadam, A K

    2018-03-01

    As regards the significant role of stethoscopes in the diagnosis of congenital and adventitious heart diseases and prevention of irreparable complications of these diseases, the quality of hearing sound of these stethoscopes by a physician has a significant impact on the disease diagnosis. This device plays an important role in the early diagnosis of congenital heart and respiratory diseases and provides this feasibility since birth. Also, the importance of this device performance in the diagnosis of heart, cardiovascular and respiratory diseases at different age periods is not a secret. This new invented device, in comparison to a variety of available stethoscopes in the field of diagnosis, is capable of hearing the sound of a very high quality and cancelling the noise of sound that sometimes leads to wrong diagnosis or misdiagnosis. This new invented stethoscope is approved by cardiologists, lung and Infectious disease specialists as well as being registered under No. 78382 in Patent Islamic Republic of Iran.

  4. A New Stethoscope Design with Unique Characteristics and Development in Medical Device

    PubMed Central

    Ghahramanifar, M.; Haghani, M.; Ghadimi Moghadam, A.; Ghadimi Moghadam, A.K.

    2018-01-01

    As regards the significant role of stethoscopes in the diagnosis of congenital and adventitious heart diseases and prevention of irreparable complications of these diseases, the quality of hearing sound of these stethoscopes by a physician has a significant impact on the disease diagnosis. This device plays an important role in the early diagnosis of congenital heart and respiratory diseases and provides this feasibility since birth. Also, the importance of this device performance in the diagnosis of heart, cardiovascular and respiratory diseases at different age periods is not a secret. This new invented device, in comparison to a variety of available stethoscopes in the field of diagnosis, is capable of hearing the sound of a very high quality and cancelling the noise of sound that sometimes leads to wrong diagnosis or misdiagnosis. This new invented stethoscope is approved by cardiologists, lung and Infectious disease specialists as well as being registered under No. 78382 in Patent Islamic Republic of Iran. PMID:29732350

  5. Development and Assessment of a Dual-Mode, Noise-Immune Stethoscope for Combat Environments

    DTIC Science & Technology

    2010-04-01

    unusable. A need exists for a stethoscope that can detect heart and lung auscultation in the presence of fixed- and rotary-wing aircraft, as well as...in ambulances and other operational environments where the ambient noise level precludes auscultation with a standard stethoscope. Possessing this...allows auscultation in high-noise environments. Because even modern military vehicles do not produce acoustic energy at the ultrasound carrier

  6. Can education influence stethoscope hygiene?

    PubMed

    Holleck, Jürgen L; Merchant, Naseema; Lin, Shin; Gupta, Shaili

    2017-07-01

    The importance of stethoscope hygiene has been demonstrated in prior studies, and is acknowledged by guidelines, yet it is rarely done. We implemented a pilot project consisting of provider education, reminder flyers and provision of cleaning supplies at the start of clinical rotations for housestaff, medical students, and attending physicians. Hand hygiene rates did not change significantly with rates between 58% and 63% while stethoscope hygiene remained at zero. Published by Elsevier Inc.

  7. Can we measure the ankle-brachial index using only a stethoscope? A pilot study.

    PubMed

    Carmo, G A L; Mandil, A; Nascimento, B R; Arantes, B D; Bittencourt, J C; Falqueto, E B; Ribeiro, A L

    2009-02-01

    Ankle-brachial index (ABI) is an excellent method for the diagnosis of peripheral arterial disease (PAD) when it is performed with Doppler. However, this device is not always available for primary care physicians. The ABI measured with stethoscope is an easy alternative approach, but have not been proved to be useful. To assess the accuracy of the ABI measured using a stethoscope comparatively to that of the current eligible method for the diagnosis of PAD, the Doppler ABI, and describe the characteristics of this new approach. We conducted a diagnostic study of ABI measured with a stethoscope and a Doppler probe and compared the results. Eighty-eight patients were accessed by both methods. Mean stethoscope ABI, 1.01 +/- 0.15, and mean Doppler ABI, 1.03 +/- 0.20, (P = 0.047) displayed a good correlation. Measurements of stethoscope ABI diagnostic accuracy in recognizing a Doppler ABI are described. The comparison of this data with the current gold standard method results gave a sensitivity of 71.4% [95% confidence interval (CI), 41.9-91.6] and specificity of 91.0% (95% CI, 81.5-96.6), with predictive positive value of 62.5% (95% CI, 38.6-81.5) and negative predictive value of 93.8% (95% CI, 85.2-97.6). The study accuracy was 87.7%. The area under the ROC curve was 0.895 (95% CI, 0.804-0.986, P < 0.0001). According to our study, the stethoscope ABI is a useful method to detect PAD and it may be suitable for its screening in the primary care setting.

  8. Validity and reliability of acoustic analysis of respiratory sounds in infants

    PubMed Central

    Elphick, H; Lancaster, G; Solis, A; Majumdar, A; Gupta, R; Smyth, R

    2004-01-01

    Objective: To investigate the validity and reliability of computerised acoustic analysis in the detection of abnormal respiratory noises in infants. Methods: Blinded, prospective comparison of acoustic analysis with stethoscope examination. Validity and reliability of acoustic analysis were assessed by calculating the degree of observer agreement using the κ statistic with 95% confidence intervals (CI). Results: 102 infants under 18 months were recruited. Convergent validity for agreement between stethoscope examination and acoustic analysis was poor for wheeze (κ = 0.07 (95% CI, –0.13 to 0.26)) and rattles (κ = 0.11 (–0.05 to 0.27)) and fair for crackles (κ = 0.36 (0.18 to 0.54)). Both the stethoscope and acoustic analysis distinguished well between sounds (discriminant validity). Agreement between observers for the presence of wheeze was poor for both stethoscope examination and acoustic analysis. Agreement for rattles was moderate for the stethoscope but poor for acoustic analysis. Agreement for crackles was moderate using both techniques. Within-observer reliability for all sounds using acoustic analysis was moderate to good. Conclusions: The stethoscope is unreliable for assessing respiratory sounds in infants. This has important implications for its use as a diagnostic tool for lung disorders in infants, and confirms that it cannot be used as a gold standard. Because of the unreliability of the stethoscope, the validity of acoustic analysis could not be demonstrated, although it could discriminate between sounds well and showed good within-observer reliability. For acoustic analysis, targeted training and the development of computerised pattern recognition systems may improve reliability so that it can be used in clinical practice. PMID:15499065

  9. A visual stethoscope to detect the position of the tracheal tube.

    PubMed

    Kato, Hiromi; Suzuki, Akira; Nakajima, Yoshiki; Makino, Hiroshi; Sanjo, Yoshimitsu; Nakai, Takayoshi; Shiraishi, Yoshito; Katoh, Takasumi; Sato, Shigehito

    2009-12-01

    Advancing a tracheal tube into the bronchus produces unilateral breath sounds. We created a Visual Stethoscope that allows real-time fast Fourier transformation of the sound signal and 3-dimensional (frequency-amplitude-time) color rendering of the results on a personal computer with simultaneous processing of 2 individual sound signals. The aim of this study was to evaluate whether the Visual Stethoscope can detect bronchial intubation in comparison with auscultation. After induction of general anesthesia, the trachea was intubated with a tracheal tube. The distance from the incisors to the carina was measured using a fiberoptic bronchoscope. While the anesthesiologist advanced the tracheal tube from the trachea to the bronchus, another anesthesiologist auscultated breath sounds to detect changes of the breath sounds and/or disappearance of bilateral breath sounds for every 1 cm that the tracheal tube was advanced. Two precordial stethoscopes placed at the left and right sides of the chest were used to record breath sounds simultaneously. Subsequently, at a later date, we randomly entered the recorded breath sounds into the Visual Stethoscope. The same anesthesiologist observed the visualized breath sounds on the personal computer screen processed by the Visual Stethoscope to examine changes of breath sounds and/or disappearance of bilateral breath sound. We compared the decision made based on auscultation with that made based on the results of the visualized breath sounds using the Visual Stethoscope. Thirty patients were enrolled in the study. When irregular breath sounds were auscultated, the tip of the tracheal tube was located at 0.6 +/- 1.2 cm on the bronchial side of the carina. Using the Visual Stethoscope, when there were any changes of the shape of the visualized breath sound, the tube was located at 0.4 +/- 0.8 cm on the tracheal side of the carina (P < 0.01). When unilateral breath sounds were auscultated, the tube was located at 2.6 +/- 1.2 cm on the bronchial side of the carina. The tube was also located at 2.3 +/- 1.0 cm on the bronchial side of the carina when a unilateral shape of visualized breath sounds was obtained using the Visual Stethoscope (not significant). During advancement of the tracheal tube, alterations of the shape of the visualized breath sounds using the Visual Stethoscope appeared before the changes of the breath sounds were detected by auscultation. Bilateral breath sounds disappeared when the tip of the tracheal tube was advanced beyond the carina in both groups.

  10. High-fidelity digital recording and playback sphygmomanometry system: device description and proof of concept.

    PubMed

    Lee, Jongshill; Chee, Youngjoon; Kim, Inyoung; Karpettas, Nikos; Kollias, Anastasios; Atkins, Neil; Stergiou, George S; O'Brien, Eoin

    2015-10-01

    This study describes the development of a new digital sphygmocorder (DS-II), which allows the digital recording and playback of the Korotkoff sounds, together with cuff pressure waveform, and its performance in a pilot validation study. A condenser microphone and stethoscope head detect Korotkoff sounds and an electronic chip, dedicated to audio-signal processing, is used to record high-quality sounds. Systolic and diastolic blood pressure (SBP/DBP) are determined from the recorded signals with an automatic beat detection algorithm that displays the cuff pressure at each beat on the monitor. Recordings of Korotkoff sounds, with the cuff pressure waveforms, and the simultaneous on-site assessments of SBP/DBP were performed during 100 measurements in 10 individuals. The observers reassessed the recorded signals to verify their accuracy and differences were calculated. The features of the high-fidelity DS-II, the technical specifications and the assessment procedures utilizing the playback software are described. Interobserver absolute differences (mean±SD) in measurements were 0.7±1.1/1.3±1.3 mmHg (SBP/DBP) with a mercury sphygmomanometer and 0.3±0.9/0.8±1.2 mmHg with the DS-II. The absolute DS-II mercury sphygmomanometer differences were 1.3±1.9/1.5±1.3 mmHg (SBP/DBP). The high-fidelity DS-II device presents satisfactory agreement with simultaneous measurements of blood pressure with a mercury sphygmomanometer. The device will be a valuable methodology for validating new blood pressure measurement technologies and devices.

  11. Research Advances In Medical Care For Polytrauma Injuries And Blast Injuries

    DTIC Science & Technology

    2011-01-25

    by air or ground ambulance. • A stethoscope that can be used to listen to heart and breath sounds in the challenging environment • The ability for...ability of medical personnel in both military and civilian settings. Description The noise immune stethoscope can be used in high-noise environments...The new stethoscope uses a traditional acoustic listening mode with the addition of ultrasound-based technology that is “noise immune.” Current

  12. The two types of stethoscope systems for respiration system diagnostics of the human body

    NASA Astrophysics Data System (ADS)

    Abashkin, Vladimir; Achimova, Elena

    2003-12-01

    An acoustic multimode fiber optic sensors for medical diagnostics based upon the shutter principle has been elaborated with semiconductor laser diode as light source. The construction and the method of component preparation are described. Other type of stethoscope is electrical one. Both stethoscopes are four channels. The kinetics and dynamic vibrations and sounds of the human body can be detected, acquired and then processing by personal computer for medical diagnostics.

  13. Auscultation

    MedlinePlus

    ... is usually done using a tool called a stethoscope. Health care providers routinely listen to a person's ... unborn infants. This can be done with a stethoscope or with sound waves (called Doppler ultrasound). Auscultation ...

  14. Breath sounds

    MedlinePlus

    The lung sounds are best heard with a stethoscope. This is called auscultation. Normal lung sounds occur ... the bottom of the rib cage. Using a stethoscope, the doctor may hear normal breathing sounds, decreased ...

  15. [Stethoscope or staphyloscope?: Potential vector in nosocomial infections].

    PubMed

    Zúniga, Andrés; Mañalich, Jaime; Cortés, Rosario

    2016-02-01

    Healthcare-associated infections (HCAI) are a problem worldwide. In our country, the estimated incidence of HCAI is 70,000 per year. This results in an increase in the average length of hospital stay by 10 days per patient, an estimated annual cost of US $ 70 million and an overstay of 700 thousand bed days a year. For over 30 years stethoscopes have been considered as potential HCAI vectors, since pathogens like methicillin-resistant Staphylococcus aureus and vancomycin-resistant Enterococcus strains adhere and colonize them. These organisms can be transmitted between patients if the instruments are not sanitized. Several studies conclude that disinfecting the stethoscope with isopropyl alcohol eliminates up to 99% of bacteria. Simple, economic measures such as implementation of guidelines for stethoscope disinfection are a clear opportunity for preventing infections.

  16. New Stethoscope With Extensible Diaphragm.

    PubMed

    Takashina, Tsunekazu; Shimizu, Masashi; Muratake, Torakazu; Mayuzumi, Syuichi

    2016-08-25

    This study compared the diagnostic efficacy of the common suspended diaphragm stethoscope (SDS) with a new extensible diaphragm stethoscope (EDS) for low-frequency heart sounds. The EDS was developed by using an ethylene propylene diene monomer diaphragm. The results showed that the EDS enhanced both the volume and quality of low-frequency heart sounds, and improved the ability of examiners to auscultate such heart sounds. Based on the results of the sound analysis, the EDS is more efficient than the SDS. (Circ J 2016; 80: 2047-2049).

  17. Explanatory model for sound amplification in a stethoscope

    NASA Astrophysics Data System (ADS)

    Eshach, H.; Volfson, A.

    2015-01-01

    In the present paper we suggest an original physical explanatory model that explains the mechanism of the sound amplification process in a stethoscope. We discuss the amplification of a single pulse, a continuous wave of certain frequency, and finally we address the resonant frequencies. It is our belief that this model may provide students with opportunities to not only better understand the amplification mechanism of a stethoscope, but also to strengthen their understanding of sound, pressure, waves, resonance modes, etc.

  18. Reception of the stethoscope and Laënnec's book.

    PubMed Central

    Bishop, P J

    1981-01-01

    A study of contemporary book reviews and other notices enables us to trace the reception of the stethoscope and Laënnec's book between 1816 and 1826. It is quite clear from these that the stethoscope was welcomed with enthusiasm by most people who saw it as the first major diagnostic tool medicine had ever had. Laënnec's book was recognised as being the most important, interesting, accurate, and complete work on diseases of the chest that had ever been published. PMID:7031968

  19. Celebrating Two Centuries since the Invention of the Stethoscope. René Théophile Hyacinthe Laënnec (1781-1826).

    PubMed

    Tomos, Ioannis; Karakatsani, Anna; Manali, Effrosyni D; Papiris, Spyros A

    2016-10-01

    René Théophile Hyacinthe Laënnec (1781-1826), a French physician, is considered one of the pioneers of respiratory medicine. His contribution to the invention of the stethoscope and to the development of clinical auscultation played a key role in the progress of the diagnosis of chest diseases. Almost two centuries after his invention of the stethoscope, his achievements continue to be widely appreciated and used by modern physicians in current pulmonology.

  20. Heart Murmurs (For Kids)

    MedlinePlus

    ... and bone between the murmur and the doctor's stethoscope. Many normal murmurs become harder to hear as ... also will listen to your heart with a stethoscope, check your pulse, and listen to your lungs. ...

  1. Latex allergies - for hospital patients

    MedlinePlus

    ... bands used to stop or slow blood flow) Stethoscopes (used to listen to your heart beat and ... the hospital include asking for: Equipment, such as stethoscopes and blood pressure cuffs, to be covered, so ...

  2. Heart sounds analysis via esophageal stethoscope system in beagles.

    PubMed

    Park, Sang Hi; Shin, Young Duck; Bae, Jin Ho; Kwon, Eun Jung; Lee, Tae-Soo; Shin, Ji-Yun; Kim, Yeong-Cheol; Min, Gyeong-Deuk; Kim, Myoung hwan

    2013-10-01

    Esophageal stethoscope is less invasive and easy to handling. And it gives a lot of information. The purpose of this study is to investigate the correlation of blood pressure and heart sound as measured by esophageal stethoscope. Four male beagles weighing 10 to 12 kg were selected as experimental subjects. After general anesthesia, the esophageal stethoscope was inserted. After connecting the microphone, the heart sounds were visualized and recorded through a self-developed equipment and program. The amplitudes of S1 and S2 were monitored real-time to examine changes as the blood pressure increased and decreased. The relationship between the ratios of S1 to S2 (S1/S2) and changes in blood pressure due to ephedrine was evaluated. The same experiment was performed with different concentration of isoflurane. From S1 and S2 in the inotropics experiment, a high correlation appeared with change in blood pressure in S1. The relationship between S1/S2 and change in blood pressure showed a positive correlation in each experimental subject. In the volatile anesthetics experiment, the heart sounds decreased as MAC increased. Heart sounds were analyzed successfully with the esophageal stethoscope through the self-developed program and equipment. A proportional change in heart sounds was confirmed when blood pressure was changed using inotropics or volatile anesthetics. The esophageal stethoscope can achieve the closest proximity to the heart to hear sounds in a non-invasive manner.

  3. Novel approach to the diagnosis of fractures in an austere environment using a stethoscope and a cellular phone.

    PubMed

    Matzek, Brett A; Fivecoat, Phillip T; Ritz, Reis B

    2014-03-01

    Fracture diagnosis in the austere environment where radiographic tests are not available can be a challenge. In the past, a diagnostic technique has been described using a tuning fork and stethoscope to assess decreased sound conduction in the fractured extremity. In this study, we evaluate the use of a cellular phone's vibrate function and a stethoscope to limit equipment carried by expeditionary practitioners. The purpose of this study was to evaluate the accuracy of fracture diagnosis using a cellular phone and stethoscope. This is a pilot study to assess the usefulness of the above technique before clinical implementation. In 3 cadavers, we created fractures of the humerus and femur. Twenty-seven emergency medicine residents and an attending physician performed the diagnostic technique. Overall, the use of the cellular phone and stethoscope resulted in a sensitivity of 73% (95% confidence interval [CI]: 0.64 to 0.81) and a specificity of 83% (95% CI: 0.77 to 0.88), with a positive predicted value of 68% (95% CI: 0.59 to 0.77) and a negative predicted value of 86% (95% CI: 0.81 to 0.90). Positive likelihood ratio was 4.3, and negative likelihood ratio was 0.32. The use of a cellular phone and stethoscope may be a useful tool for the diagnosis of fractures in the austere environment. However, further study is needed to validate these findings in the clinical environment. Published by Wilderness Medical Society on behalf of Wilderness Medical Society.

  4. An alternative noninvasive technique for the treatment of iatrogenic femoral pseudoaneurysms: stethoscope-guided compression.

    PubMed

    Korkmaz, Ahmet; Duyuler, Serkan; Kalayci, Süleyman; Türker, Pinar; Sahan, Ekrem; Maden, Orhan; Selçuk, Mehmet Timur

    2013-06-01

    latrogenic femoral pseudoaneurysm is a well-known vascular access site complication. Many invasive and noninvasive techniques have been proposed for the management of this relatively common complication. In this study, we aimed to evaluate efficiency and safety of stethoscope-guided compression as a novel noninvasive technique in the femoral pseudoaneurysm treatment. We prospectively included 29 consecutive patients with the diagnosis of femoral pseudoaneurysm who underwent coronary angiography. Patients with a clinical suspicion of femoral pseudoaneurysm were referred to colour Doppler ultrasound evaluation. The adult (large) side of the stethoscope was used to determine the location where the bruit was best heard. Then compression with the paediatric (small) side of the stethoscope was applied until the bruit could no longer be heard and compression was maintained for at least two sessions. Once the bruit disappeared, a 12-hour bed rest with external elastic compression was advised to the patients, in order to prevent disintegration of newly formed thrombosis. Mean pseudoaneurysm size was 1.7 +/- 0.4 cmx 3.0 +/- 0.9 cm and the mean duration of compression was 36.2 +/- 8.5 minutes.Twenty-six (89.6%) of these 29 patients were successfully treated with stethoscope-guided compression. In 18 patients (62%), the pseuodoaneurysms were successfully closed after 2 sessions of 15-minute compression. No severe complication was observed. Stethoscope-guided compression of femoral pseudoaneurysms is a safe and effective novel technique which requires less equipment and expertise than other contemporary methods.

  5. Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement.

    PubMed

    Liu, Chengyu; Griffiths, Clive; Murray, Alan; Zheng, Dingchang

    2016-06-01

    This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant.

  6. Comparison of stethoscope bell and diaphragm, and of stethoscope tube length, for clinical blood pressure measurement

    PubMed Central

    Griffiths, Clive; Murray, Alan; Zheng, Dingchang

    2016-01-01

    Objective This study investigated the effect of stethoscope side and tube length on auscultatory blood pressure (BP) measurement. Methods Thirty-two healthy participants were studied. For each participant, four measurements with different combinations of stethoscope characteristics (bell or diaphragm side, standard or short tube length) were each recorded at two repeat sessions, and eight Korotkoff sound recordings were played twice on separate days to one experienced listener to determine the systolic and diastolic BPs (SBP and DBP). Analysis of variance was carried out to study the measurement repeatability between the two repeat sessions and between the two BP determinations on separate days, as well as the effects of stethoscope side and tube length. Results There was no significant paired difference between the repeat sessions and between the repeat determinations for both SBP and DBP (all P-values>0.10, except the repeat session for SBP using short tube and diaphragm). The key result was that there was a small but significantly higher DBP on using the bell in comparison with the diaphragm (0.66 mmHg, P=0.007), and a significantly higher SBP on using the short tube in comparison with the standard length (0.77 mmHg, P=0.008). Conclusion This study shows that stethoscope characteristics have only a small, although statistically significant, influence on clinical BP measurement. Although this helps understand the measurement technique and resolves questions in the published literature, the influence is not clinically significant. PMID:26741415

  7. In defense of the stethoscope.

    PubMed

    Murphy, Raymond Lh

    2008-03-01

    The stethoscope is widely considered to be an unreliable instrument. Many studies document the significant observer variability in its use. Numerous other diagnostic tools are available that are generally regarded to provide more reliable diagnostic information. Some even argue that teaching of the ancient art should be de-emphasized in medical schools. Yet auscultation with an acoustic stethoscope can provide important, even life-saving, information. The purpose of this article is to present evidence that supports the use of the stethoscope in clinical medicine. The argument for the stethoscope will be made by presenting relevant investigations, including clinical studies acknowledged to meet the criteria of evidence-based medicine. It will focus on studies that have employed computerized acoustic technology to correlate lung sounds with disease states. This technology has advanced in recent years, which has stimulated a resurgence of interest in auscultation. Numerous studies have been done that utilized objective methods that circumvented the problem of observer variability. There is now a good deal of scientific evidence to support the hypothesis that lung sounds contain information that is clinically useful. This technology also allows this information to be collected more efficiently than previously possible. Advances in educational technology have made it possible to impart information on auscultation much more easily than was possible in the past. Contrary to predictions, the stethoscope is not likely to be relegated to the museum shelf in the near future. Computer technology is making it an even more useful clinical instrument.

  8. The efficacy of stethoscope placement when not in use: traditional versus “cool”

    PubMed Central

    Hanley, William B.; Hanley, Anthony J.G.

    2000-01-01

    Objective To determine whether the “cool” or circumcervical placement of the stethoscope when not in use is as efficacious as the traditional placement in terms of transfer time to the functional position. Methods Measurement of time taken by 100 health care professionals in each group to transfer stethoscope to functional position. Results and interpretation The cool group was much slower than the traditional group, despite their younger years. This wasted time could translate into a substantial financial burden on Canada's health care system. PMID:11138413

  9. Contamination of stethoscopes and physicians' hands after a physical examination.

    PubMed

    Longtin, Yves; Schneider, Alexis; Tschopp, Clément; Renzi, Gesuèle; Gayet-Ageron, Angèle; Schrenzel, Jacques; Pittet, Didier

    2014-03-01

    To compare the contamination level of physicians' hands and stethoscopes and to explore the risk of cross-transmission of microorganisms through the use of stethoscopes. We conducted a structured prospective study between January 1, 2009, and May 31, 2009, involving 83 inpatients at a Swiss university teaching hospital. After a standardized physical examination, 4 regions of the physician's gloved or ungloved dominant hand and 2 sections of the stethoscopes were pressed onto selective and nonselective media; 489 surfaces were sampled. Total aerobic colony counts (ACCs) and total methicillin-resistant Staphylococcus aureus (MRSA) colony-forming unit (CFU) counts were assessed. Median total ACCs (interquartile range) for fingertips, thenar eminence, hypothenar eminence, hand dorsum, stethoscope diaphragm, and tube were 467, 37, 34, 8, 89, and 18, respectively. The contamination level of the diaphragm was lower than the contamination level of the fingertips (P<.001) but higher than the contamination level of the thenar eminence (P=.004). The MRSA contamination level of the diaphragm was higher than the MRSA contamination level of the thenar eminence (7 CFUs/25 cm(2) vs 4 CFUs/25 cm(2); P=.004). The correlation analysis for both total ACCs and MRSA CFU counts revealed that the contamination level of the diaphragm was associated with the contamination level of the fingertips (Spearman's rank correlation coefficient, ρ=0.80; P<.001 and ρ=0.76; P<.001, respectively). Similarly, the contamination level of the stethoscope tube increased with the increase in the contamination level of the fingertips for both total ACCs and MRSA CFU counts (ρ=0.56; P<.001 and ρ=.59; P<.001, respectively). These results suggest that the contamination level of the stethoscope is substantial after a single physical examination and comparable to the contamination of parts of the physician's dominant hand. Copyright © 2014 Mayo Foundation for Medical Education and Research. Published by Elsevier Inc. All rights reserved.

  10. Ventricular Septal Defect (VSD)

    MedlinePlus

    ... hears a murmur while listening to your baby's heart with a stethoscope. Sometimes VSDs can be detected by ultrasound before ... murmur your doctor hears when listening to your heart with a stethoscope. When to see a doctor Call your doctor ...

  11. Enhancing Health-Care Services with Mixed Reality Systems

    NASA Astrophysics Data System (ADS)

    Stantchev, Vladimir

    This work presents a development approach for mixed reality systems in health care. Although health-care service costs account for 5-15% of GDP in developed countries the sector has been remarkably resistant to the introduction of technology-supported optimizations. Digitalization of data storing and processing in the form of electronic patient records (EPR) and hospital information systems (HIS) is a first necessary step. Contrary to typical business functions (e.g., accounting or CRM) a health-care service is characterized by a knowledge intensive decision process and usage of specialized devices ranging from stethoscopes to complex surgical systems. Mixed reality systems can help fill the gap between highly patient-specific health-care services that need a variety of technical resources on the one side and the streamlined process flow that typical process supporting information systems expect on the other side. To achieve this task, we present a development approach that includes an evaluation of existing tasks and processes within the health-care service and the information systems that currently support the service, as well as identification of decision paths and actions that can benefit from mixed reality systems. The result is a mixed reality system that allows a clinician to monitor the elements of the physical world and to blend them with virtual information provided by the systems. He or she can also plan and schedule treatments and operations in the digital world depending on status information from this mixed reality.

  12. Reliability of Doppler and stethoscope methods of determining systolic blood pressures: considerations for calculating an ankle-brachial index.

    PubMed

    Chesbro, Steven B; Asongwed, Elmira T; Brown, Jamesha; John, Emmanuel B

    2011-01-01

    The purposes of this study were to: (1) identify the interrater and intrarater reliability of systolic blood pressures using a stethoscope and Doppler to determine an ankle-brachial index (ABI), and (2) to determine the correlation between the 2 methods. Peripheral arterial disease (PAD) affects approximately 8 to 12 million people in the United States, and nearly half of those with this disease are asymptomatic. Early detection and prompt treatment of PAD will improve health outcomes. It is important that clinicians perform tests that determine the presence of PAD. Two individual raters trained in ABI procedure measured the systolic blood pressures of 20 individuals' upper and lower extremities. Standard ABI measurement protocols were observed. Raters individually recorded the systolic blood pressures of each extremity using a stethoscope and a Doppler, for a total of 640 independent measures. Interrater reliability of Doppler measurements to determine SBP at the ankle was very strong (intraclass correlation coefficient [ICC], 0.93-0.99) compared to moderate to strong reliability using a stethoscope (ICC, 0.64-0.87). Agreement between the 2 devices to determine SBP was moderate to very weak (ICC, 0.13-0.61). Comparisons of the use of Doppler and stethoscope to determine ABI showed weak to very weak intrarater correlation (ICC, 0.17-0.35). Linear regression analysis of the 2 methods to determine ABI showed positive but weak to very weak correlations (r2 = .013, P = .184). A Doppler ultrasound is recommended over a stethoscope for accuracy in systolic pressure readings for ABI measurements.

  13. A new cardiology patient simulator.

    PubMed

    Takashina, T; Shimizu, M; Katayama, H

    1997-01-01

    We report a new cardiology patient simulator developed through the application of new digital computer technology, capable of playing back selected physical findings (jugular-venous waves, arterial pulses of carotid, brachial, radial and femoral arteries, and cardiac impulses), as well as cardiac sounds, murmurs and respiratory sounds that have been prerecorded from actual patients. The examining physician uses an ordinary type of stethoscope. Four built-in speakers are located in the human-sized mannequin at the classic auscultatory sites (aortic, pulmonic, tricuspid and mitral). This compact and portable educational apparatus should facilitate medical training in the bedside cardiac examination, of physicians, medical students, nurses and paramedics throughout the world.

  14. iStethoscope: a demonstration of the use of mobile devices for auscultation.

    PubMed

    Bentley, Peter J

    2015-01-01

    iStethoscope Pro is the first piece of software (an "App") produced for iOS devices, which enabled users to exploit their smartphones, music players, or tablets as stethoscopes. The software exploits the built-in microphone (and supports externally added microphones) and performs real-time amplification and filtering to enable heart sounds to be heard with high fidelity. The software also enables the heart sounds to be recorded, analyzed using a spectrogram, and to be transmitted to others via e-mail. This chapter describes the motivation, functionality, and results from this work.

  15. Environmental Contaminants in Hospital Settings and Progress in Disinfecting Techniques

    PubMed Central

    Ceriale, Emma; Lenzi, Daniele; Burgassi, Sandra; Azzolini, Elena; Manzi, Pietro

    2013-01-01

    Medical devices, such as stethoscopes, and other objects found in hospital, such as computer keyboards and telephone handsets, may be reservoirs of bacteria for healthcare-associated infections. In this cross-over study involving an Italian teaching hospital we evaluated microbial contamination (total bacterial count (TBC) at 36°C/22°C, Staphylococcus spp., moulds, Enterococcus spp., Pseudomonas spp., E. coli, total coliform bacteria, Acinetobacter spp., and Clostridium difficile) of these devices before and after cleaning and differences in contamination between hospital units and between stethoscopes and keyboards plus handsets. We analysed 37 telephone handsets, 27 computer keyboards, and 35 stethoscopes, comparing their contamination in four hospital units. Wilcoxon signed-rank and Mann-Whitney tests were used. Before cleaning, many samples were positive for Staphylococcus spp. and coliforms. After cleaning, CFUs decreased to zero in most comparisons. The first aid unit had the highest and intensive care the lowest contamination (P < 0.01). Keyboards and handsets had higher TBC at 22°C (P = 0.046) and mould contamination (P = 0.002) than stethoscopes. Healthcare professionals should disinfect stethoscopes and other possible sources of bacterial healthcare-associated infections. The cleaning technique used was effective in reducing bacterial contamination. Units with high patient turnover, such as first aid, should practise stricter hygiene. PMID:24286078

  16. Use of 90% ethanol to decontaminate stethoscopes in resource limited settings.

    PubMed

    Raghubanshi, Bijendra Raj; Sapkota, Supriya; Adhikari, Arjab; Dutta, Aman; Bhattarai, Utsuk; Bhandari, Rastriyata

    2017-01-01

    In developing countries like Nepal, 90% ethanol is cheap and is available in most hospitals. The unavailability of isopropyl alcohol (IPA) in these settings led us to compare the efficacy between 90% ethanol and isopropyl alcohol pads in reducing the bacterial contamination of diaphragm of stethoscope. A randomized blinded experimental study was carried out to determine the difference between cleaning stethoscopes with 90% ethanol and IPA. Cultures of diaphragm were taken before and after cleaning with one of the cleaning agent. Colony forming units (CFU) count and organism identification was done by a blinded investigator. CFU before and after cleaning were compared using Wilcoxon signed-rank test. Mann Whitney U test was used to compare the decrease in CFU count between the cleaning agents. About 30% of the stethoscopes harbored potential pathogens. Significant reduction in CFU was observed with both IPA (Wilcoxon signed-rank test, P value <0.001) and 90% ethanol (Wilcoxon signed-rank test, P value <0.001). Comparing median decrease in CFU between cleaning with IPA and with 90% ethanol, no significant difference was found (Mann Whitney U test; U = 1357, P value >0.05). Both 90% ethanol and IPA are equally effective in decontaminating the diaphragm of stethoscope. Selection of agent should be done on the basis of cost and availability.

  17. The patient-surgeon relationship in the cyber era: communication and information.

    PubMed

    Blake, J Herman; Schwemmer, Mary Kay; Sade, Robert M

    2012-11-01

    From Laennec's invention of the stethoscope in 1816 to the recently introduced Sapien transcatheter aortic valve replacement, the increasing complexity of health care technology has altered the relationship between patients and physicians, usually for the better. Telemedicine, the provision of medical services through electronic media, has dramatically changed how the patient and physician interact and how medical care is delivered. Many studies of physicians' perceptions of electronic communication with patients have documented recognition of benefits as well as a consistent chorus of concerns about confidentiality, increased workload, inappropriate use, and medicolegal issues. Copyright © 2012 Elsevier Inc. All rights reserved.

  18. Correlation of blood pressure and the ratio of S1 to S2 as measured by esophageal stethoscope and wireless bluetooth transmission.

    PubMed

    Hoon Lim, Kyoung; Duck Shin, Young; Hi Park, Sang; Ho Bae, Jin; Jae Lee, Hong; Jung Kim, Seon; Yun Shin, Ji; Jin Choi, Young

    2013-07-01

    Objective : Esophageal stethoscope has the advantage of being non-invasive, easily placed and capability to monitor the heart sound. This study was designed to determine whether the ratio of S1 to S2 analyzed by esophageal stethoscope and wireless bluetooth transmission can be accurate indicator that express the correlation with blood pressure. Total 33 adult male and female without cardiac disorder and with normal heart rhythm were selected randomly as the subjects of this Study. Two microphones were used with one for acquisition of heart sound by connecting it to the esophageal stethoscope while the other was used to measure the background noise in the operating room. After having transmitted the heart sound measured with the esophageal stethoscope to the receiver by using bluetooth module, it was saved in PC and outputted, following removal of noise in the operating room and the respiratory sound. S1 and S2 were measured with computation of the ratio of S1 to S2. Correlations between the systolic blood pressure with each of the S1, S2 and ratio of S1 to S2 were examined by using correlation analysis. The ratio of S1 to S2 displayed the highest correlation with the systolic blood pressure, with S1 and S2 also displaying positive correlation with the systolic blood pressure. As the result of analysis of the heart sound and the systolic blood pressure measured by using the esophageal stethoscope, the radio of S1 to S2 displayed greater correlation with the systolic blood pressure in comparison to the S1.

  19. Time Effectiveness of Ultraviolet C Light (UVC) Emitted by Light Emitting Diodes (LEDs) in Reducing Stethoscope Contamination.

    PubMed

    Messina, Gabriele; Fattorini, Mattia; Nante, Nicola; Rosadini, Daniele; Serafini, Andrea; Tani, Marco; Cevenini, Gabriele

    2016-09-23

    Today it is well demonstrated that stethoscopes can be as contaminated as hands, which are a recognized source of Health-Care Associated Infections (HCAIs). Ultraviolet C (UVC) light has proven disinfection capacity and the innovative UVC technology of Light Emitting Diode (LED) shows several potential benefits. To verify whether the use of UVC LEDs is effective and reliable in stethoscope membrane disinfection after prolonged use, a pre-post intervention study was conducted. A total of 1668 five-minute cycles were performed on two UVC LEDs to simulate their use; thereafter, their disinfection capacity was tested on stethoscope membranes used on a previously auscultated volunteer. Then, a further 1249 cycles were run and finally the LEDs were tested to assess performance in reducing experimental contamination by Staphylococcus aureus, Pseudomonas aeruginosa and Escherichia coli on the stethoscope membrane. Baseline volunteer contamination identified 104 Colony Forming Units (CFUs) while treated Petri dishes had 12 and 15 CFUs (p < 0.001). Statistically significant differences (p < 0.001) were also found relating to the reduction of specific bacteria: in particular, after treatment no CFU were observed for S. aureus and E. coli. UVC LEDs demonstrated the capacity to maintain high levels of disinfection after more than 240 h of use and they were effective against common microorganisms that are causative agents of HCAIs.

  20. Time Effectiveness of Ultraviolet C Light (UVC) Emitted by Light Emitting Diodes (LEDs) in Reducing Stethoscope Contamination

    PubMed Central

    Messina, Gabriele; Fattorini, Mattia; Nante, Nicola; Rosadini, Daniele; Serafini, Andrea; Tani, Marco; Cevenini, Gabriele

    2016-01-01

    Today it is well demonstrated that stethoscopes can be as contaminated as hands, which are a recognized source of Health-Care Associated Infections (HCAIs). Ultraviolet C (UVC) light has proven disinfection capacity and the innovative UVC technology of Light Emitting Diode (LED) shows several potential benefits. To verify whether the use of UVC LEDs is effective and reliable in stethoscope membrane disinfection after prolonged use, a pre-post intervention study was conducted. A total of 1668 five-minute cycles were performed on two UVC LEDs to simulate their use; thereafter, their disinfection capacity was tested on stethoscope membranes used on a previously auscultated volunteer. Then, a further 1249 cycles were run and finally the LEDs were tested to assess performance in reducing experimental contamination by Staphylococcus aureus, Pseudomonas aeruginosa and Escherichia coli on the stethoscope membrane. Baseline volunteer contamination identified 104 Colony Forming Units (CFUs) while treated Petri dishes had 12 and 15 CFUs (p < 0.001). Statistically significant differences (p < 0.001) were also found relating to the reduction of specific bacteria: in particular, after treatment no CFU were observed for S. aureus and E. coli. UVC LEDs demonstrated the capacity to maintain high levels of disinfection after more than 240 h of use and they were effective against common microorganisms that are causative agents of HCAIs. PMID:27669273

  1. A systematic review of novel technology for monitoring infant and newborn heart rate.

    PubMed

    Kevat, Ajay C; Bullen, Denise V R; Davis, Peter G; Kamlin, C Omar F

    2017-05-01

    Heart rate (HR) is a vital sign for assessing the need for resuscitation. We performed a systematic review of studies assessing novel methods of measuring HR in newborns and infants in the neonatal unit. Two investigators completed independent literature searches. Identified papers were independently evaluated, and relevant data were extracted and analysed. This systematic review identified seven new technologies, including camera-based photoplethysmography, reflectance pulse oximetry, laser Doppler methods, capacitive sensors, piezoelectric sensors, electromyography and a digital stethoscope. Clinicians should be aware of several of these, which may become available for clinical use in the near future. ©2017 Foundation Acta Paediatrica. Published by John Wiley & Sons Ltd.

  2. A novel multimedia tool to improve bedside teaching of cardiac auscultation

    PubMed Central

    Woywodt, A; Herrmann, A; Kielstein, J; Haller, H; Haubitz, M; Purnhagen, H

    2004-01-01

    Training in cardiac auscultation is a core element of undergraduate teaching but recent studies have documented a remarkable decline in auscultatory skills. Therefore there is an interest in new ways to teach cardiac auscultation. In analogy to phonocardiography, an electronic system for simultaneous auscultation and visualisation of murmurs was sought. For this purpose, an electronic stethoscope was linked to a laptop computer and software created to visualise auscultatory findings. In a preliminary trial in undergraduate students, this approach greatly facilitated teaching. Amalgamating traditional phonocardiography with a multimedia approach, this system represents a novel tool for bedside teaching of cardiac auscultation. PMID:15192171

  3. Utilizing lung sounds analysis for the evaluation of acute asthma in small children.

    PubMed

    Tinkelman, D G; Lutz, C; Conner, B

    1991-09-01

    One of the most difficult aspects of management of acute asthma in the small child is the clinician's inability to quantitate the response or lack of response to bronchodilator agents because of the inability of a child this age to perform objective lung measurements in the acute state. The present study was designed to evaluate bronchodilator responsiveness in children between 2 and 6 years of age with wheezing by means of a computerized lung sound analysis, computer digitized airway phonopneumonography. Children between ages 2 and 6 who were experiencing acute exacerbations of asthma were included in this study population. The 43 children were evaluated by physical examination, pulmonary function testing, if possible, by use of (spirometry or peak flow meter) and transmission of lung sounds to a computer using an electronic stethoscope to obtain a phonopneumograph with sound intensity level determinations during tidal breathing. A control group of 20 known asthmatic patients between the ages of 8 and 52 years who also presented to the office with acute asthma were evaluated similarly. In each of these individuals, a physical examination was followed by complete spirometry as well as computer digitized airway phonopneumonography recordings. Following initial measurements, all patients were treated with nebulized albuterol (0.25 mL in 2 mL of saline). Five minutes after completion of the nebulization all patients were reexamined and repeat pulmonary function tests were performed followed by CDAP recordings. In the study group of children, the mean pretreatment sound intensity level was 1,694 (range 557 to 4,950 SD +/- 745).(ABSTRACT TRUNCATED AT 250 WORDS)

  4. Explanatory Model for Sound Amplification in a Stethoscope

    ERIC Educational Resources Information Center

    Eshach, H.; Volfson, A.

    2015-01-01

    In the present paper we suggest an original physical explanatory model that explains the mechanism of the sound amplification process in a stethoscope. We discuss the amplification of a single pulse, a continuous wave of certain frequency, and finally we address the resonant frequencies. It is our belief that this model may provide students with…

  5. Vital Signs Rate Meter.

    DTIC Science & Technology

    1987-09-01

    stethoscope . Auscultation in respiratory medicine, however, has advanced slowly since Laennec established auscultation of lung sounds as a means of... stethoscope and the ear have limitations in their use as instruments for the evaluation of respiratory sounds. Respiratory sounds have a wide spectrum...Amplification, Rectification and Level-shft ing Stage ... 11 Respiratory Sound Circuitry ....... .................. ... 11 Sound Sensor

  6. Bronchial intubation could be detected by the visual stethoscope techniques in pediatric patients.

    PubMed

    Kimura, Tetsuro; Suzuki, Akira; Mimuro, Soichiro; Makino, Hiroshi; Sato, Shigehito

    2012-12-01

    We created a system that allows the visualization of breath sounds (visual stethoscope). We compared the visual stethoscope technique with auscultation for the detection of bronchial intubation in pediatric patients. In the auscultation group, an anesthesiologist advanced the tracheal tube, while another anesthesiologist auscultated bilateral breath sounds to detect the change and/or disappearance of unilateral breath sounds. In the visualization group, the stethoscope was used to detect changes in breath sounds and/or disappearance of unilateral breath sounds. The distance from the edge of the mouth to the carina was measured using a fiberoptic bronchoscope. Forty pediatric patients were enrolled in the study. At the point at which irregular breath sounds were auscultated, the tracheal tube was located at 0.5 ± 0.8 cm on the bronchial side from the carina. When a detectable change of shape of the visualized breath sound was observed, the tracheal tube was located 0.1 ± 1.2 cm on the bronchial side (not significant). At the point at which unilateral breath sounds were auscultated or a unilateral shape of the visualized breath sound was observed, the tracheal tube was 1.5 ± 0.8 or 1.2 ± 1.0 cm on the bronchial side, respectively (not significant). The visual stethoscope allowed to display the left and the right lung sound simultaneously and detected changes of breath sounds and unilateral breath sound as a tracheal tube was advanced. © 2012 Blackwell Publishing Ltd.

  7. Decontamination of stethoscope membranes with chlorhexidine: Should it be recommended?

    PubMed

    Álvarez, José A; Ruíz, Susana R; Mosqueda, Juan L; León, Ximena; Arreguín, Virginia; Macías, Alejandro E; Macias, Juan H

    2016-11-01

    To determine differences in the recontamination of stethoscope membranes after cleaning with chlorhexidine, triclosan, or alcohol. Experimental, controlled, blinded trial to determine differences in the bacterial load on stethoscope membranes. Membranes were cultured by direct imprint after disinfection with 70% isopropyl alcohol, 1% triclosan, or 1% chlorhexidine and normal use for 4 hours. As a baseline and an immediate effect control, bacterial load of membranes without disinfection and after 1 minute of disinfection with isopropyl alcohol was determined as well. Three hundred seventy cultures of in-use stethoscopes were taken, 74 from each arm. In the baseline arm the median growth was 10 CFU (interquartile range [IQR], 32-42 CFU); meanwhile, in the isopropyl alcohol immediate-effect arm it was 0 CFU (IQR, 0-0 CFU). In the arms cultured after 4 hours, a median growth of 8 CFU (IQR, 1-28 CFU) in the isopropyl alcohol arm, 4 CFU (IQR, 0-17 CFU) in the triclosan arm, and 0 CFU (IQR, 0-1 CFU) in the chlorhexidine arm were seen. No significant differences were observed between the bacterial load of the chlorhexidine arm (after 4 hours of use) and that of the isopropyl alcohol arm (after 1 minute without use) (Z= 2.41; P > .05). Chlorhexidine can inhibit recontamination of stethoscope membranes and its use could help avoid cross-infection. Copyright © 2016 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  8. Anesthesia Provider’s Use of the Precordial or Esophageal Stethoscope: Is Anyone Still Listening to the Patient

    DTIC Science & Technology

    1996-06-01

    USAF, NC and Dr. Maura McAuliffe, Lt. Col. , USAF, NC. Dr. Hall served as my qualitative data advisor. Her assi stance ensured an accurate...esophageal stethoscope, Anesthesiology, 65 (5), 534-536. Prielipp, R. c., Kelly , J. S., & Roy, R. C. (1995, August). Use of esophageal or

  9. Hand-held computers in healthcare: what software programs are available?

    PubMed

    Gillingham, Wayne; Holt, Alec; Gillies, John

    2002-09-27

    The technology sector of healthcare is entering a new evolutionary phase. The medical community has an obligation to the public to provide the safest, most effective healthcare possible. This is more achievable with the use of computer technology at the point of care, and small, portable devices could fulfil this role. A PriceWaterhouse Coopers 2001 survey on information technology in physician practices found that 60% of respondents say that physicians in their organisation use personal digital assistants (PDAs), compared with 26% in the 2000 technology survey. This trend is expected to continue to the point where these devices will have their position on a physician s desk next to the stethoscope. Once this electronic evolution occurs, doctors will be able to practice medicine with greater ease and safety. In our opinion, the new generation of PDA mobile devices will be the tools to enable a transformation of healthcare to a paperless, wireless world. This article focuses on uses of PDAs in healthcare, whether by the registrar, consultant, nurse, student, teacher, patient, medical or surgical director. Current PDA healthcare software is categorised and discussed in the following five groups: 1) reference/text book; 2) calculator; 3) patient management/logbook; 4) personal clinical/study notebook; 5) utility software.

  10. A sneak peek into digital innovations and wearable sensors for cardiac monitoring.

    PubMed

    Michard, Frederic

    2017-04-01

    Many mobile phone or tablet applications have been designed to control cardiovascular risk factors (obesity, smoking, sedentary lifestyle, diabetes and hypertension) or to optimize treatment adherence. Some have been shown to be useful but the long-term benefits remain to be demonstrated. Digital stethoscopes make easier the interpretation of abnormal heart sounds, and the development of pocket-sized echo machines may quickly and significantly expand the use of ultrasounds. Daily home monitoring of pulmonary artery pressures with wireless implantable sensors has been shown to be associated with a significant decrease in hospital readmissions for heart failure. There are more and more non-invasive, wireless, and wearable sensors designed to monitor heart rate, heart rate variability, respiratory rate, arterial oxygen saturation, and thoracic fluid content. They have the potential to change the way we monitor and treat patients with cardiovascular diseases in the hospital and beyond. Some may have the ability to improve quality of care, decrease the number of medical visits and hospitalization, and ultimately health care costs. Validation and outcome studies are needed to clarify, among the growing number of digital innovations and wearable sensors, which tools have real clinical value.

  11. Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope.

    PubMed

    Ching, Siok Siong; Tan, Yih Kai

    2012-09-07

    To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3M™ Littmann(®) Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, sound-to-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. A total of 71 patients were studied during the period July 2009 to January 2011. Forty patients had acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant difference was seen between acute large bowel obstruction and large bowel pseudo-obstruction. For patients with small bowel obstruction, the sound-to-sound interval was significantly longer in those who subsequently underwent surgery compared with those treated non-operatively (median 1.29 s vs 0.63 s, P < 0.001). There was no correlation between bowel calibre and bowel sound characteristics in both acute small bowel obstruction and acute large bowel obstruction. Auscultation of bowel sounds is non-specific for diagnosing bowel obstruction. Differences in sound characteristics between large bowel and small bowel obstruction may help determine the likely site of obstruction.

  12. Spectral analysis of bowel sounds in intestinal obstruction using an electronic stethoscope

    PubMed Central

    Ching, Siok Siong; Tan, Yih Kai

    2012-01-01

    AIM: To determine the value of bowel sounds analysis using an electronic stethoscope to support a clinical diagnosis of intestinal obstruction. METHODS: Subjects were patients who presented with a diagnosis of possible intestinal obstruction based on symptoms, signs, and radiological findings. A 3M™ Littmann® Model 4100 electronic stethoscope was used in this study. With the patients lying supine, six 8-second recordings of bowel sounds were taken from each patient from the lower abdomen. The recordings were analysed for sound duration, sound-to-sound interval, dominant frequency, and peak frequency. Clinical and radiological data were reviewed and the patients were classified as having either acute, subacute, or no bowel obstruction. Comparison of bowel sound characteristics was made between these subgroups of patients. In the presence of an obstruction, the site of obstruction was identified and bowel calibre was also measured to correlate with bowel sounds. RESULTS: A total of 71 patients were studied during the period July 2009 to January 2011. Forty patients had acute bowel obstruction (27 small bowel obstruction and 13 large bowel obstruction), 11 had subacute bowel obstruction (eight in the small bowel and three in large bowel) and 20 had no bowel obstruction (diagnoses of other conditions were made). Twenty-five patients received surgical intervention (35.2%) during the same admission for acute abdominal conditions. A total of 426 recordings were made and 420 recordings were used for analysis. There was no significant difference in sound-to-sound interval, dominant frequency, and peak frequency among patients with acute bowel obstruction, subacute bowel obstruction, and no bowel obstruction. In acute large bowel obstruction, the sound duration was significantly longer (median 0.81 s vs 0.55 s, P = 0.021) and the dominant frequency was significantly higher (median 440 Hz vs 288 Hz, P = 0.003) when compared to acute small bowel obstruction. No significant difference was seen between acute large bowel obstruction and large bowel pseudo-obstruction. For patients with small bowel obstruction, the sound-to-sound interval was significantly longer in those who subsequently underwent surgery compared with those treated non-operatively (median 1.29 s vs 0.63 s, P < 0.001). There was no correlation between bowel calibre and bowel sound characteristics in both acute small bowel obstruction and acute large bowel obstruction. CONCLUSION: Auscultation of bowel sounds is non-specific for diagnosing bowel obstruction. Differences in sound characteristics between large bowel and small bowel obstruction may help determine the likely site of obstruction. PMID:22969233

  13. Difference in thermodynamics between two types of esophageal temperature probes: Insights from an experimental study.

    PubMed

    Gianni, Carola; Atoui, Moustapha; Mohanty, Sanghamitra; Trivedi, Chintan; Bai, Rong; Al-Ahmad, Amin; Burkhardt, J David; Gallinghouse, G Joseph; Hranitzky, Patrick M; Horton, Rodney P; Sanchez, Javier E; Di Biase, Luigi; Lakkireddy, Dhanunjaya R; Natale, Andrea

    2016-11-01

    Luminal esophageal temperature monitoring is performed with a variety of temperature probes, but little is known about the relationship between the structure of a given probe and its thermodynamic characteristics. The purpose of this study was to evaluate the difference in thermodynamics between a 9Fr standard esophageal probe and an 18Fr esophageal stethoscope. In the experimental setting, each probe was submerged in a constant temperature water bath maintained at 42°C; in the patient setting, we monitored the temperature with both probes at the same time. The time constant of the stethoscope was higher than that of the probe (33.5 vs 8.3 s). Compared to the probe, the mean temperature measured by the stethoscope at 10 seconds was significantly lower (22.5°C ± 0.4°C vs 33.5°C ± 0.3°C, P<.0001), whereas the time to reach the peak temperature was significantly longer (132.6 ± 5.9 s vs 38.8 ± 1.0 s, P<.0001). Even in the ablation cases we observed that when the esophageal probe reached a peak temperature of 39.6°C ± 0.3°C, the esophageal stethoscope still displayed a temperature of 37.3°C ± 0.2°C (a mean of 2.39°C ± 0.3°C lower, P<.0001), showing a <0.5°C increase in temperature half of the times. The 18Fr esophageal stethoscope has a significantly slower time response compared to the 9Fr esophageal probe. In the clinical setting, this might result in a considerable underestimation of the luminal esophageal temperature with potentially fatal consequences. Copyright © 2016 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.

  14. Reference values for respiratory rate in the first 3 years of life.

    PubMed

    Rusconi, F; Castagneto, M; Gagliardi, L; Leo, G; Pellegatta, A; Porta, N; Razon, S; Braga, M

    1994-09-01

    Raised respiratory rate is a useful sign to diagnose lower respiratory infections in childhood. However, the normal range for respiratory rate has not been defined in a proper, large sample. To assess the respiratory rate in a large number of infants and young children in order to construct percentile curves by age; to determine the repeatability to the assessment using a stethoscope and compare it with observation. Respiratory rate was recorded for 1 minute with a stethoscope in 618 infants and children, aged 15 days to 3 years old, without respiratory infections or any other severe disease when awake and calm and when asleep. In 50 subjects we compared respiratory rate taken 30 to 60 minutes apart to assess repeatability, and in 50 others we compared simultaneous counts obtained by stethoscope versus observation. Repeatability was good as the standard deviation of differences was 2.5 breaths/minute in awake and 1.7 breaths/minute in asleep children. Respiratory rate obtained with a stethoscope was systematically higher than that obtained by observation (mean difference 2.6 breaths/minute in awake and 1.8 breaths/minute in asleep children; P = .015 and P < .001, respectively). A decrease in respiratory rate with age was seen for both states, and it was faster in the first few months of life when also a greater dispersion of values was observed. A second degree polynomial curve accurately fitted the data. Reference percentile values were developed from these data. The repeatability of respiratory rate measured with a stethoscope was good. Percentile curves would be particularly helpful in the first months of life when the decline in respiratory rate is very rapid and prevents to use cut off values for defining "normality."

  15. Preliminary Characterization of the Noise-Immune Stethoscope (NIS) in High Ambient Noise Environment Using a Reverberation Sound Chamber

    DTIC Science & Technology

    2010-02-01

    unlimited This report details the preliminary testing of advanced technology development for clinical auscultation in high noise environments. The Noise...represents a viable answer to the need for clinical auscultation in high noise environments across the spectrum of casualty care. stethoscope, auscultation ...sounds, and these sounds prove very useful for clinical assessment and diagnosis (Bloch, 1993). Since that time, clinical auscultation by way of a

  16. Portable bedside ultrasound: the visual stethoscope of the 21st century

    PubMed Central

    2012-01-01

    Over the past decade technological advances in the realm of ultrasound have allowed what was once a cumbersome and large machine to become essentially hand-held. This coupled with a greater understanding of lung sonography has revolutionized our bedside assessment of patients. Using ultrasound not as a diagnostic test, but instead as a component of the physical exam, may allow it to become the stethoscope of the 21st century. PMID:22400903

  17. Remote optical stethoscope and optomyography sensing device

    NASA Astrophysics Data System (ADS)

    Golberg, Mark; Polani, Sagi; Ozana, Nisan; Beiderman, Yevgeny; Garcia, Javier; Ruiz-Rivas Onses, Joaquin; Sanz Sabater, Martin; Shatsky, Max; Zalevsky, Zeev

    2017-02-01

    In this paper we present the usage of photonic remote laser based device for sensing nano-vibrations for detection of muscle contraction and fatigue, eye movements and in-vivo estimation of glucose concentration. The same concept is also used to realize a remote optical stethoscope. The advantage of doing the measurements from a distance is in preventing passage of infections as in the case of optical stethoscope or in the capability to monitor e.g. sleep quality without disturbing the patient. The remote monitoring of glucose concentration in the blood stream and the capability to perform opto-myography for the Messer muscles (chewing) is very useful for nutrition and weight control. The optical configuration for sensing the nano-vibrations is based upon analyzing the statistics of the secondary speckle patterns reflected from various tissues along the body of the subjects. Experimental results present the preliminary capability of the proposed configuration for the above mentioned applications.

  18. Lung and Heart Sounds Analysis: State-of-the-Art and Future Trends.

    PubMed

    Padilla-Ortiz, Ana L; Ibarra, David

    2018-01-01

    Lung sounds, which include all sounds that are produced during the mechanism of respiration, may be classified into normal breath sounds and adventitious sounds. Normal breath sounds occur when no respiratory problems exist, whereas adventitious lung sounds (wheeze, rhonchi, crackle, etc.) are usually associated with certain pulmonary pathologies. Heart and lung sounds that are heard using a stethoscope are the result of mechanical interactions that indicate operation of cardiac and respiratory systems, respectively. In this article, we review the research conducted during the last six years on lung and heart sounds, instrumentation and data sources (sensors and databases), technological advances, and perspectives in processing and data analysis. Our review suggests that chronic obstructive pulmonary disease (COPD) and asthma are the most common respiratory diseases reported on in the literature; related diseases that are less analyzed include chronic bronchitis, idiopathic pulmonary fibrosis, congestive heart failure, and parenchymal pathology. Some new findings regarding the methodologies associated with advances in the electronic stethoscope have been presented for the auscultatory heart sound signaling process, including analysis and clarification of resulting sounds to create a diagnosis based on a quantifiable medical assessment. The availability of automatic interpretation of high precision of heart and lung sounds opens interesting possibilities for cardiovascular diagnosis as well as potential for intelligent diagnosis of heart and lung diseases.

  19. Pathogenesis and Treatment of Cerebral Air Embolism and Associated Disorders.

    DTIC Science & Technology

    1984-04-01

    blades) 12. 7.0, 8.0 and 9.0-mm endotracheal tubes 13. Endotracheal tube stylet 14. Esophageal obturator airway 15. Tracheal suction catheters (14F) 17 r...16. Nasogastric suction tube and Tumee syringe 17. Tincture of Benzoin 18. 2-in waterproof tape 19. Precordial stethoscope 20. Esophageal stethoscope...be justified. If an endotracheal tube cannot be passed, an esophageal obturator airway may be useful. If such an airway Is used, the newer models

  20. Two-modality γ detection of blood volume by camera imaging and nonimaging stethoscope for kinetic studies of cardiovascular control in nuclear medicine

    NASA Astrophysics Data System (ADS)

    Eclancher, Bernard; Chambron, Jacques; Dumitresco, Barbu; Karman, Miklos; Pszota, Agnes; Simon, Atilla; Didon-Poncelet, Anna; Demangeat, Jean

    2002-04-01

    The quantification of rapid hemodynamic reactions to wide and slow breathing movements has been performed, by two modalities (gamma) -left ventriculography of 99mTc-labeled blood volume, in anterior oblique incidence on standing and even exercising healthy volunteers and cardiac patients. A highly sensitive stethoscope delivered whole (gamma) -counts acquired at 30 msec intervals in a square field of view including the left ventricle, in a one dimensional low resolution imaging mode for beat to beat analysis. A planar 2D (gamma) -camera imaging of the same cardiac area was then performed without cardiac gating for alternate acquisitions during deep inspiration and deep expiration, completed by a 3D MRI assessment of the stethoscope detection field. Young healthy volunteers displayed wide variations of diastolic times and stroke volumes, as a result of enhanced baroreflex control, together with +/- 16% variations of the stethoscope's background blood volume counts. Any of the components of these responses were shifted, abolished or even inverted as a result of either obesity, hypertension, aging or cardiac pathologies. The assessment of breathing control of the cardiovascular system by the beat to beat (gamma) -ventriculography combined with nuclear 2D and 3D MRI imaging is a kinetic method allowing the detection of functional anomalies in still ambulatory patients.

  1. Experimental validation of the tuneable diaphragm effect in modern acoustic stethoscopes.

    PubMed

    Nowak, Karolina M; Nowak, Lukasz J

    2017-09-01

    The force with which the diaphragm chestpiece of a stethoscope is pressed against the body of a patient during an auscultation examination introduces the initial stress and deformation to the diaphragm and the underlying tissues, thus altering the acoustic parameters of the sound transmission path. If the examination is performed by an experienced physician, he will intuitively adjust the amount of the force in order to achieve the optimal sound quality. However, in case of becoming increasingly popular auto-diagnosis and telemedicine auscultation devices with no such feedback mechanisms, the question arises regarding the influence of the possible force mismatch on the parameters of the recorded signal. The present study describes the results of the experimental investigations on the relation between pressure applied to the chestpiece of a stethoscope and parameters of the transmitted bioacoustic signals. The experiments were carried out using various stethoscopes connected to a force measurement system, which allowed to maintain fixed pressure during auscultation examinations. The signals were recorded during examinations of different volunteers, at various auscultation sites. The obtained results reveal strong individual and auscultation-site variability. It is concluded that the underlying tissue deformation is the primary factor that alters the parameters of the recorded signals. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  2. Clinical Examination Component of Telemedicine, Telehealth, mHealth, and Connected Health Medical Practices.

    PubMed

    Weinstein, Ronald S; Krupinski, Elizabeth A; Doarn, Charles R

    2018-05-01

    Telemedicine and telehealth are the practices of medicine at a distance. Performing the equivalent of a complete clinical examination by telemedicine would be unusual. However, components of a more traditional clinical examination are part of the telemedicine workup for specific conditions. Telemedicine clinical examinations are facilitated, and enhanced, through the integration of a class of medical devices referred to as telemedicine peripherals (eg, electronic stethoscopes, tele-ophthalmoscopes, video-otoscopes, and so forth). Direct-to-consumer telehealth is a rapidly expanding segment of the health care service industry. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. Thoracic auscultation in captive bottlenose dolphins (Tursiops truncatus), California sea lions (Zalophus californianus), and South African fur seals (Arctocephalus pusillus) with an electronic stethoscope.

    PubMed

    Scharpegge, Julia; Hartmann, Manuel García; Eulenberger, Klaus

    2012-06-01

    Thoracic auscultation is an important diagnostic method used in cases of suspected pulmonary disease in many species, as respiratory sounds contain significant information on the physiology and pathology of the lungs and upper airways. Respiratory diseases are frequent in marine mammals and are often listed as one of their main causes of death. The aim of this study was to investigate and report baseline parameters for the electronic-mediated thoracic auscultation of one cetacean species and two pinniped species in captivity. Respiratory sounds from 20 captive bottlenose dolphins (Tursiops truncatus), 6 California sea lions (Zalophus californianus), and 5 South African fur seals (Arctocephalus pusillus) were recorded with an electronic stethoscope. The sounds were analyzed for duration of the respiratory cycle, adventitious sounds, and peak frequencies of recorded sounds during expiration and inspiration as well as for sound intensity as reflected by waveform amplitude during the respiratory cycle. In respiratory cycles of the bottlenose dolphins' expiring "on command," the duration of the expiration was significantly shorter than the duration of the inspiration. In the examined pinnipeds of this study, there was no clear pattern concerning the duration of one breathing phase: Adventitious sounds were detected most often in bottlenose dolphins that were expiring on command and could be compared with "forced expiratory wheezes" in humans. This is the first report of forced expiratory wheezes in bottlenose dolphins; they can easily be misinterpreted as pathologic respiratory sounds. The peak frequencies of the respiratory sounds reached over 2,000 Hz in bottlenose dolphins and over 1,000 Hz in California sea lions and South African fur seals, but the variation of the frequency spectra was very high in all animals. To the authors' knowledge, this is the first systematic analysis of respiratory sounds of bottlenose dolphins and two species of pinnipeds.

  4. Diagnostic validity of methods for assessment of swallowing sounds: a systematic review.

    PubMed

    Taveira, Karinna Veríssimo Meira; Santos, Rosane Sampaio; Leão, Bianca Lopes Cavalcante de; Neto, José Stechman; Pernambuco, Leandro; Silva, Letícia Korb da; De Luca Canto, Graziela; Porporatti, André Luís

    2018-02-03

    Oropharyngeal dysphagia is a highly prevalent comorbidity in neurological patients and presents a serious health threat, which may lead to outcomes of aspiration pneumonia, ranging from hospitalization to death. This assessment proposes a non-invasive, acoustic-based method to differentiate between individuals with and without signals of penetration and aspiration. This systematic review evaluated the diagnostic validity of different methods for assessment of swallowing sounds, when compared to Videofluroscopic of Swallowing Study (VFSS) to detect oropharyngeal dysphagia. Articles in which the primary objective was to evaluate the accuracy of swallowing sounds were searched in five electronic databases with no language or time limitations. Accuracy measurements described in the studies were transformed to construct receiver operating characteristic curves and forest plots with the aid of Review Manager v. 5.2 (The Nordic Cochrane Centre, Copenhagen, Denmark). The methodology of the selected studies was evaluated using the Quality Assessment Tool for Diagnostic Accuracy Studies-2. The final electronic search revealed 554 records, however only 3 studies met the inclusion criteria. The accuracy values (area under the curve) were 0.94 for microphone, 0.80 for Doppler, and 0.60 for stethoscope. Based on limited evidence and low methodological quality because few studies were included, with a small sample size, from all index testes found for this systematic review, Doppler showed excellent diagnostic accuracy for the discrimination of swallowing sounds, whereas microphone-reported good accuracy discrimination of swallowing sounds of dysphagic patients and stethoscope showed best screening test. Copyright © 2018 Associação Brasileira de Otorrinolaringologia e Cirurgia Cérvico-Facial. Published by Elsevier Editora Ltda. All rights reserved.

  5. Infrasonic Stethoscope for Monitoring Physiological Processes

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Shams, Qamar A. (Inventor); Dimarcantonio, Albert L. (Inventor)

    2018-01-01

    An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece.

  6. Infrasonic Stethoscope for Monitoring Physiological Processes

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Shams, Qamar A. (Inventor); Dimarcantonio, Albert L. (Inventor)

    2016-01-01

    An infrasonic stethoscope for monitoring physiological processes of a patient includes a microphone capable of detecting acoustic signals in the audible frequency bandwidth and in the infrasonic bandwidth (0.03 to 1000 Hertz), a body coupler attached to the body at a first opening in the microphone, a flexible tube attached to the body at a second opening in the microphone, and an earpiece attached to the flexible tube. The body coupler is capable of engagement with a patient to transmit sounds from the person, to the microphone and then to the earpiece.

  7. Utility of physical examination and comparison to echocardiography for cardiac diagnosis.

    PubMed

    Patel, Ashish; Tomar, Nitin Singh; Bharani, Anil

    To find out the accuracy of cardiac auscultation using non-digital stethoscope in physical diagnosis of cardiac diseases. We enrolled 104 consecutive patients with abnormal cardiac auscultatory findings attending cardiology clinic and not previously evaluated by echocardiography. One time detailed cardiac physical examination followed by echocardiography within 1 month was undertaken. Agreement between two methods was calculated using mean pair percentage agreement, kappa statistics (κ) and calculation of 95% confidence interval (CI) for kappa statistics. Using kappa statistics, there was almost perfect agreement between cardiac auscultation and echocardiography for the detection of mitral stenosis (κ=0.865; CI 0.76-0.97) and ventricular septal defect (κ=0.872; CI=0.73-1.01). Substantial agreement was noted for aortic stenosis (κ=0.752; CI=0.56-0.94), pulmonary stenosis (κ=0.647; CI=0.33-0.97) and atrial septal defect (κ=0.646; CI=0.32-0.97), while moderate agreement was found for mitral regurgitation (κ=0.470; CI=0.30-0.64), aortic regurgitation (κ=0.456; CI=0.25-0.66) and tricuspid regurgitation (κ=0.575; CI=0.38-0.77). For combined mitral stenosis and mitral regurgitation lesions, almost perfect agreement was found for mitral stenosis (κ=0.842; CI=0.691-0.993) while fair agreement noted for mitral regurgitation (κ=0.255; CI=-0.008 to 0.518). Careful clinical auscultation using a stethoscope remains a valuable tool for cardiac diagnosis. Decision on initial diagnosis and management of valvular and congenital heart diseases should be based on clinical examination and integrating such information with echocardiography as required. Copyright © 2016 Cardiological Society of India. Published by Elsevier B.V. All rights reserved.

  8. A Study to Determine the Most Cost-Effective Method of Delivering Obstetrical Care to All Eligible Beneficiaries within the Kenner Army Community Hospital’s Catchment Area

    DTIC Science & Technology

    1988-07-05

    ONITOR FETAL 10952.72 651501C725660 I MNrITOR OXYGEN 783.92 651501C725692 I PLMP BREAST MECHANICAL 1106.39 651501C725694 I STETHOSCOPE ULTRASOJ’D...TODDLEP 1496.12 651501C725969 I MONITOR, PHYSIOLOGICAL SYST, EMSS 2258.21 651501C726026 I FETAL HEART MCONITOR 9937.20 651501C726162 I OXI ETER, PULSE...THERMWTER FARE𔃾-EIT ELECTRONIC W/-ARGER 303.55 651501C725211 I MONITOR FETAL PULSE 1305.42 651501C725442 2 PUMP INFUSION VOLLUETRIC 1834.71 65150IC725596 I

  9. Noise Reduction in Breath Sound Files Using Wavelet Transform Based Filter

    NASA Astrophysics Data System (ADS)

    Syahputra, M. F.; Situmeang, S. I. G.; Rahmat, R. F.; Budiarto, R.

    2017-04-01

    The development of science and technology in the field of healthcare increasingly provides convenience in diagnosing respiratory system problem. Recording the breath sounds is one example of these developments. Breath sounds are recorded using a digital stethoscope, and then stored in a file with sound format. This breath sounds will be analyzed by health practitioners to diagnose the symptoms of disease or illness. However, the breath sounds is not free from interference signals. Therefore, noise filter or signal interference reduction system is required so that breath sounds component which contains information signal can be clarified. In this study, we designed a filter called a wavelet transform based filter. The filter that is designed in this study is using Daubechies wavelet with four wavelet transform coefficients. Based on the testing of the ten types of breath sounds data, the data is obtained in the largest SNRdB bronchial for 74.3685 decibels.

  10. Automated lung sound analysis for detecting pulmonary abnormalities.

    PubMed

    Datta, Shreyasi; Dutta Choudhury, Anirban; Deshpande, Parijat; Bhattacharya, Sakyajit; Pal, Arpan

    2017-07-01

    Identification of pulmonary diseases comprises of accurate auscultation as well as elaborate and expensive pulmonary function tests. Prior arts have shown that pulmonary diseases lead to abnormal lung sounds such as wheezes and crackles. This paper introduces novel spectral and spectrogram features, which are further refined by Maximal Information Coefficient, leading to the classification of healthy and abnormal lung sounds. A balanced lung sound dataset, consisting of publicly available data and data collected with a low-cost in-house digital stethoscope are used. The performance of the classifier is validated over several randomly selected non-overlapping training and validation samples and tested on separate subjects for two separate test cases: (a) overlapping and (b) non-overlapping data sources in training and testing. The results reveal that the proposed method sustains an accuracy of 80% even for non-overlapping data sources in training and testing.

  11. A robust dataset-agnostic heart disease classifier from Phonocardiogram.

    PubMed

    Banerjee, Rohan; Dutta Choudhury, Anirban; Deshpande, Parijat; Bhattacharya, Sakyajit; Pal, Arpan; Mandana, K M

    2017-07-01

    Automatic classification of normal and abnormal heart sounds is a popular area of research. However, building a robust algorithm unaffected by signal quality and patient demography is a challenge. In this paper we have analysed a wide list of Phonocardiogram (PCG) features in time and frequency domain along with morphological and statistical features to construct a robust and discriminative feature set for dataset-agnostic classification of normal and cardiac patients. The large and open access database, made available in Physionet 2016 challenge was used for feature selection, internal validation and creation of training models. A second dataset of 41 PCG segments, collected using our in-house smart phone based digital stethoscope from an Indian hospital was used for performance evaluation. Our proposed methodology yielded sensitivity and specificity scores of 0.76 and 0.75 respectively on the test dataset in classifying cardiovascular diseases. The methodology also outperformed three popular prior art approaches, when applied on the same dataset.

  12. Respiratory modulation of oscillometric cuff pressure pulses and Korotkoff sounds during clinical blood pressure measurement in healthy adults.

    PubMed

    Chen, Diliang; Chen, Fei; Murray, Alan; Zheng, Dingchang

    2016-05-10

    Accurate blood pressure (BP) measurement depends on the reliability of oscillometric cuff pressure pulses (OscP) and Korotkoff sounds (KorS) for automated oscillometric and manual techniques. It has been widely accepted that respiration is one of the main factors affecting BP measurement. However, little is known about how respiration affects the signals from which BP measurement is obtained. The aim was to quantify the modulation effect of respiration on oscillometric pulses and KorS during clinical BP measurement. Systolic and diastolic BPs were measured manually from 40 healthy subjects (from 23 to 65 years old) under normal and regular deep breathing. The following signals were digitally recorded during linear cuff deflation: chest motion from a magnetometer to obtain reference respiration, cuff pressure from an electronic pressure sensor to derive OscP, and KorS from a digital stethoscope. The effects of respiration on both OscP and KorS were determined from changes in their amplitude associated with respiration between systole and diastole. These changes were normalized to the mean signal amplitude of OscP and KorS to derive the respiratory modulation depth. Reference respiration frequency, and the frequencies derived from the amplitude modulation of OscP and KorS were also calculated and compared. Respiratory modulation depth was 14 and 40 % for OscP and KorS respectively under normal breathing condition, with significant increases (both p < 0.05) to 16 and 49 % with deeper breathing. There was no statistically significant difference between the reference respiration frequency and those derived from the oscillometric and Korotkoff signals (both p > 0.05) during deep breathing, and for the oscillometric signal during normal breathing (p > 0.05). Our study confirmed and quantified the respiratory modulation effect on the oscillometric pulses and KorS during clinical BP measurement, with increased modulation depth under regular deeper breathing.

  13. Improved auscultation skills in paramedic students using a modified stethoscope.

    PubMed

    Simon, Erin L; Lecat, Paul J; Haller, Nairmeen A; Williams, Carolyn J; Martin, Scott W; Carney, John A; Pakiela, John A

    2012-12-01

    The Ventriloscope® (Lecat's SimplySim, Tallmadge, OH) is a modified stethoscope used as a simulation training device for auscultation. To test the effectiveness of the Ventriloscope as a training device in teaching heart and lung auscultatory findings to paramedic students. A prospective, single-hospital study conducted in a paramedic-teaching program. The standard teaching group learned heart and lung sounds via audiocassette recordings and lecture, whereas the intervention group utilized the modified stethoscope in conjunction with patient volunteers. Study subjects took a pre-test, post-test, and a follow-up test to measure recognition of heart and lung sounds. The intervention group included 22 paramedic students and the standard group included 18 paramedic students. Pre-test scores did not differ using two-sample t-tests (standard group: t [16]=-1.63, p=0.12) and (intervention group: t [20]=-1.17, p=0.26). Improvement in pre-test to post-test scores was noted within each group (standard: t [17]=2.43, p=0.03; intervention: t [21]=4.81, p<0.0001). Follow-up scores for the standard group were not different from pre-test scores of 16.06 (t [17]=0.94, p=0.36). However, follow-up scores for the intervention group significantly improved from their respective pre-test score of 16.05 (t [21]=2.63, p=0.02). Simulation training using a modified stethoscope in conjunction with standardized patients allows for realistic learning of heart and lung sounds. This technique of simulation training achieved proficiency and better retention of heart and lung sounds in a safe teaching environment. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. The 200th anniversary of the stethoscope: Can this low-tech device survive in the high-tech 21st century?

    PubMed

    Bank, Ivan; Vliegen, Hubert W; Bruschke, Albert V G

    2016-12-14

    In 1816, Laennec discovered that auscultation of the heart and lungs could effectively be performed by placing a hollow cylinder (initially made of a roll of paper) between the chest of the patient and the ear of the examiner. This was the first step in the development of the stethoscope, which was a breakthrough in the diagnosis and management of cardiac and pulmonary patients. Technical improvements of the stethoscope followed and in cardiac patients auscultation soon became a major diagnostic tool. In the second half of the 20th century, new powerful non-invasive diagnostic modalities were developed and the interest in auscultation declined. As a result, the auscultatory skills of students and physicians at all levels of training decreased to a disappointingly low level. We now must decide whether we should stimulate the use of and proficiency in auscultation or if we should accept the further decline and eventual abolishment of this component of the physical examination. Reviewing the literature and taking into consideration the setting in which the patients are presented, including the availability of advanced diagnostic facilities, we conclude that the time-honoured stethoscope, in spite of its limitations, still has potential as a patient-friendly, effective, and economical instrument in medical practice. However, new initiatives are required to train students, physicians and allied health professionals in cardiac auscultation to avoid misinterpretations that may harm the patients and generate extra costs. To be successful such programs will require wide support from the medical community. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2016. For permissions please email: journals.permissions@oup.com.

  15. Blood pressure evaluation using sphygmomanometry assisted by arterial pulse waveform detection by fiber Bragg grating pulse device

    NASA Astrophysics Data System (ADS)

    Sharath, Umesh; Sukreet, Raju; Apoorva, Girish; Asokan, Sundarrajan

    2013-06-01

    We report a blood pressure evaluation methodology by recording the radial arterial pulse waveform in real time using a fiber Bragg grating pulse device (FBGPD). Here, the pressure responses of the arterial pulse in the form of beat-to-beat pulse amplitude and arterial diametrical variations are monitored. Particularly, the unique signatures of pulse pressure variations have been recorded in the arterial pulse waveform, which indicate the systolic and diastolic blood pressure while the patient is subjected to the sphygmomanometric blood pressure examination. The proposed method of blood pressure evaluation using FBGPD has been validated with the auscultatory method of detecting the acoustic pulses (Korotkoff sounds) by an electronic stethoscope.

  16. Soft Stethoscope for Detecting Asthma Wheeze in Young Children

    PubMed Central

    Yu, Chun; Tsai, Tzu-Hsiu; Huang, Shi-Ing; Lin, Chii-Wann

    2013-01-01

    Asthma is a chronic disease that is commonly suffered by children. Asthmatic children have a lower quality of life than other children. Physicians and pediatricians recommend that parents record the frequency of attacks and their symptoms to help manage their children's asthma. However, the lack of a convenient device for monitoring the asthmatic condition leads to the difficulties in managing it, especially when it is suffered by young children. This work develops a wheeze detection system for use at home. A small and soft stethoscope was used to collect the respiratory sound. The wheeze detection algorithm was the Adaptive Respiratory Spectrum Correlation Coefficient (RSACC) algorithm, which has the advantages of high sensitivity/specificity and a low computational requirement. Fifty-nine sound files from eight young children (one to seven years old) were collected in the emergency room and analyzed. The results revealed that the system provided 88% sensitivity and 94% specificity in wheeze detection. In conclusion, this small soft stethoscope can be easily used on young children. A noisy environment does not affect the effectiveness of the system in detecting wheeze. Hence, the system can be used at home by parents who wish to evaluate and manage the asthmatic condition of their children. PMID:23744030

  17. Soft stethoscope for detecting asthma wheeze in young children.

    PubMed

    Yu, Chun; Tsai, Tzu-Hsiu; Huang, Shi-Ing; Lin, Chii-Wann

    2013-06-06

    Asthma is a chronic disease that is commonly suffered by children. Asthmatic children have a lower quality of life than other children. Physicians and pediatricians recommend that parents record the frequency of attacks and their symptoms to help manage their children's asthma. However, the lack of a convenient device for monitoring the asthmatic condition leads to the difficulties in managing it, especially when it is suffered by young children. This work develops a wheeze detection system for use at home. A small and soft stethoscope was used to collect the respiratory sound. The wheeze detection algorithm was the Adaptive Respiratory Spectrum Correlation Coefficient (RSACC) algorithm, which has the advantages of high sensitivity/specificity and a low computational requirement. Fifty-nine sound files from eight young children (one to seven years old) were collected in the emergency room and analyzed. The results revealed that the system provided 88% sensitivity and 94% specificity in wheeze detection. In conclusion, this small soft stethoscope can be easily used on young children. A noisy environment does not affect the effectiveness of the system in detecting wheeze. Hence, the system can be used at home by parents who wish to evaluate and manage the asthmatic condition of their children.

  18. Maintaining the passion for pinards.

    PubMed

    Smith, Hannah

    2013-09-01

    Throughout my midwifery programme I have developed a passion for the use of pinards; a skill that may be lost within midwifery. It is often acknowledged that the use of pinard stethoscopes prior to the use of electronic devices is best practice (Royal College of Midwives (RCM) 2012), yet it is a practice that seems to be losing its place. This article aims to share some of the benefits of using a pinard and encourages the reader to reflect on their own feelings towards using this tool in practice. I will analyse whether or not there is still a value for pinards following an event I experienced whilst on clinical placement. This reflection uses an adapted version of Driscoll's Model of structured reflection (Driscoll 2000).

  19. Tracheal wheezes during methacholine airway challenge (MAC) in workers exposed to occupational hazards.

    PubMed

    Bohadana, A B; Massin, N; Teculescu, D; Peslin, R

    1994-09-01

    Methacholine airway challenge (MAC) is a simple and useful means to assess bronchial hyperreactivity in workers exposed to various occupational hazards. Recently, wheeze detection by tracheal auscultation has been proposed as an indicator of bronchial responsiveness during bronchial provocation test in children. Our aim was to examine the relationship between the appearance of wheezes and the concurrent changes in forced expiratory volume in one second (FEV1) observed during MAC test in adults. Three cumulative doses of a methacholine solution (100 micrograms, 500 micrograms and 1500 micrograms) were inhaled by 45 workers with occupational exposure to flour dust. Spirometry was done using an electronic spirometer. Tracheal sounds were recorded with an electronic stethoscope placed over the anterior cervical triangle, 2 cm above the sternal notch. The amplified sounds were stored on magnetic tape, band-pass filtered (50-2000 Hz), and digitized at a sampling rate of 4096 Hz into a GenRad Vibration Control System. Wheezes were detected by fast Fourier transform (FFT) analysis and their presence compared to a 20% fall in FEV1. A positive MAC test by spirometry was found in 12 subjects whereas wheezes were identified in 14 subjects. Among the wheezing subjects, nine had a positive MAC test (range of fall in FEV1 = 20.6 to 42.3%) and five had a negative one (range of fall in FEV1 = 3.6 to 16.9%). Moreover, no wheezes were found in the remaining three subjects with a positive MAC test (range of fall in FEV1 = 20.7 to 27.4%). Taking a 20% fall in FEV1 as reference, wheezes were 75% sensitive and 84.8% specific to detect airflow obstruction. In conclusion, since it carries a significant although small false-negative rate, the acoustic technique based upon wheeze detection cannot, at the present time, fully replace spirometry during airway challenge testing in subjects with suspected asthma.

  20. The Patient-Surgeon Relationship in the Cyber Era: Communication and Information

    PubMed Central

    Blake, J. Herman; Schwemmer, Mary Kay; Sade, Robert M.

    2012-01-01

    Synopsis From Laennec’s invention of the stethoscope in 1816 to the recently introduced Sapien transcatheter aortic valve replacement, the increasing complexity of health care technology has altered the relationship between patients and physicians, usually for the better. Telemedicine, the provision of medical services through electronic media, has dramatically changed how the patient and physician interact and how medical care is delivered. A consistent pattern of increased use of the Internet by patients and their families has been well documented. Patients clearly want more Internet interactions with clinicians in their quest for general information, prescription renewals, and such administrative matters as scheduling appointments. Despite privacy concerns, patients are generally satisfied that their communications and medical records are confidential and accurate. Physicians’ utilization of information technology has increased as the range of electronic devices and modes of communication has expanded. Many studies of physicians’ perceptions of electronic communication with patients have documented recognition of benefits as well as a consistent chorus of concerns about confidentiality, increased workload, inappropriate use, and medicolegal issues. PMID:23084616

  1. Safety and efficacy of misoprostol for induction of labour in a semi-urban hospital setting.

    PubMed

    Loto, O M; Fadahunsi, A A; Kolade, C O

    2004-09-01

    Most studies on the use of misoprostol for induction of labour have been carried out in well-endowed hospitals in developed countries with state-of-the-art monitoring equipment. There is need for more studies to be conducted in facilities with limited resources, if more patients are to benefit from the low cost and effectiveness of the drug. Following Ethical Committee approval, 152 women had labour induced in our maternity unit using intravaginal misoprostol. The patients were monitored clinically using the WHO model partograph with digital palpation of uterine contractions and intermittent auscultation of fetal heart with a pinard stethoscope. One hundred and thirty-five (88.8%) of the women had a vaginal delivery, while nine (5.9%) had a caesarean section for various obstetric indications. Eight cases of uterine hyperstimulation were noted but none of uterine rupture. We conclude that misoprostol can be used safely for induction of labour in less endowed hospital settings such as in developing countries, using basic clinical tools for monitoring.

  2. Comparison of lung sound transducers using a bioacoustic transducer testing system.

    PubMed

    Kraman, Steve S; Wodicka, George R; Pressler, Gary A; Pasterkamp, Hans

    2006-08-01

    Sensors used for lung sound research are generally designed by the investigators or adapted from devices used in related fields. Their relative characteristics have never been defined. We employed an artificial chest wall with a viscoelastic surface and a white noise signal generator as a stable source of sound to compare the frequency response and pulse waveform reproduction of a selection of devices used for lung sound research. We used spectral estimation techniques to determine frequency response and cross-correlation of pulses to determine pulse shape fidelity. The sensors evaluated were the Siemens EMT 25 C accelerometer (Siemens); PPG 201 accelerometer (PPG); Sony ECM-T150 electret condenser microphone with air coupler (air coupler; with cylindrical air chambers of 5-, 10-, and 15-mm diameter and conical air chamber of 10-mm diameter); Littman classic stethoscope head (Littman) connected to an electret condenser microphone; and the Andries Tek (Andries) electronic stethoscope. We found that the size and shape of the air coupler chamber to have no important effect on the detected sound. The Siemens, air coupler, and Littman performed similarly with relatively flat frequency responses from 200 to 1,200 Hz. The PPG had the broadest frequency response, with useful sensitivity extending to 4,000 Hz. The Andries' frequency response was the poorest above 1,000 Hz. Accuracy in reproducing pulses roughly corresponded with the high-frequency sensitivity of the sensors. We conclude that there are important differences among commonly used lung sound sensors that have to be defined to allow the comparison of data from different laboratories.

  3. Heart murmurs recorded by a sensor based electronic stethoscope and e-mailed for remote assessment

    PubMed Central

    Dahl, L; Hasvold, P; Arild, E; Hasvold, T; Wren, C; Dahl, L; Hasvold, P; Arild, E; Hasvold, T

    2002-01-01

    Background: Heart murmurs are common in children, and they are often referred to a specialist for examination. A clinically innocent murmur does not need further investigation. The referral area of the University Hospital is large and sparsely populated. A new service for remote auscultation (telemedicine) of heart murmurs in children was established where heart sounds and short texts were sent as an attachment to e-mails. Aim: To assess the clinical quality of this method. Methods: Heart sounds from 47 patients with no murmur (n = 7), with innocent murmurs (n = 20), or with pathological murmurs (n = 20) were recorded using a sensor based stethoscope and e-mailed to a remote computer. The sounds were repeated, giving 100 cases that were randomly distributed on a compact disc. Four cardiologists assessed and categorised the cases as having "no murmur", "innocent murmur", or "pathological murmur", recorded the assessment time per case, their degree of certainty, and whether they recommended referral. Results: On average, 2.1 minutes were spent on each case. The mean sensitivity and specificity were 89.7% and 98.2% respectively, and the inter-observer and intra-observer variabilities were low (kappa 0.81 and 0.87), respectively. A total of 93.4% of cases with a pathological murmur and 12.6% of cases with an innocent murmur were recommended for referral. Conclusion: Telemedical referral of patients with heart murmurs for remote assessment by a cardiologist is safe and saves time. Skilled auscultation is adequate to detect patients with innocent murmurs. PMID:12244000

  4. 47 CFR 32.6212 - Digital electronic switching expense.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... with digital electronic switching equipment used to provide circuit switching. (c) This subaccount 6212... 47 Telecommunication 2 2014-10-01 2014-10-01 false Digital electronic switching expense. 32.6212... Digital electronic switching expense. (a) This account shall include expenses associated with digital...

  5. 47 CFR 32.6212 - Digital electronic switching expense.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... with digital electronic switching equipment used to provide circuit switching. (c) This subaccount 6212... 47 Telecommunication 2 2011-10-01 2011-10-01 false Digital electronic switching expense. 32.6212... Digital electronic switching expense. (a) This account shall include expenses associated with digital...

  6. 47 CFR 32.6212 - Digital electronic switching expense.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... with digital electronic switching equipment used to provide circuit switching. (c) This subaccount 6212... 47 Telecommunication 2 2013-10-01 2013-10-01 false Digital electronic switching expense. 32.6212... Digital electronic switching expense. (a) This account shall include expenses associated with digital...

  7. 47 CFR 32.6212 - Digital electronic switching expense.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... with digital electronic switching equipment used to provide circuit switching. (c) This subaccount 6212... 47 Telecommunication 2 2010-10-01 2010-10-01 false Digital electronic switching expense. 32.6212... Digital electronic switching expense. (a) This account shall include expenses associated with digital...

  8. 47 CFR 32.6212 - Digital electronic switching expense.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... with digital electronic switching equipment used to provide circuit switching. (c) This subaccount 6212... 47 Telecommunication 2 2012-10-01 2012-10-01 false Digital electronic switching expense. 32.6212... Digital electronic switching expense. (a) This account shall include expenses associated with digital...

  9. In defence of auscultation: a glorious future?

    PubMed Central

    Thompson, W Reid

    2017-01-01

    Auscultation of the heart using a simple stethoscope continues to be a central aspect of the cardiovascular examination despite declining proficiency and availability of competing technologies such as hand-held ultrasound. In the ears and mind of a trained cardiologist, heart sounds can provide important information to help screen for certain diseases such as valvar lesions and many congenital defects. Using emerging technology, auscultation is poised to undergo a transformation that will simultaneously improve the teaching and evaluation of this important clinical skill and create a new generation of smart stethoscopes, capable of assisting the clinician in quickly and confidently screening for heart disease. These developments have important implications for global health, screening of athletes and recognition of congenital heart disease. PMID:28243316

  10. Comparison of the measurement of heart rate in adult free-range chickens (Gallus domesticus) by auscultation and electrocardiography.

    PubMed

    Smith, C F; Gavaghan, B J; McSweeney, D; Powell, V; Lisle, A

    2014-12-01

    To compare the heart rates of adult free-range chickens (Gallus domesticus) measured by auscultation with a stethoscope with those measured simultaneously using electrocardiography (ECG). With each bird in a standing position, estimation of the heart rate was performed by placing a mark on paper for every 4 beats for roosters and 8 beats for hens as detected by auscultation over 30 s, while simultaneous ECG was performed. Heart rates measured by auscultation showed a high correlation (r = 0.97) with those measured by ECG. There was a high correlation between the heart rates of adult free-range chickens measured by auscultation with a stethoscope and those measured simultaneously using ECG. © 2014 Australian Veterinary Association.

  11. Dysphagia Screening: Contributions of Cervical Auscultation Signals and Modern Signal-Processing Techniques

    PubMed Central

    Dudik, Joshua M.; Coyle, James L.

    2015-01-01

    Cervical auscultation is the recording of sounds and vibrations caused by the human body from the throat during swallowing. While traditionally done by a trained clinician with a stethoscope, much work has been put towards developing more sensitive and clinically useful methods to characterize the data obtained with this technique. The eventual goal of the field is to improve the effectiveness of screening algorithms designed to predict the risk that swallowing disorders pose to individual patients’ health and safety. This paper provides an overview of these signal processing techniques and summarizes recent advances made with digital transducers in hopes of organizing the highly varied research on cervical auscultation. It investigates where on the body these transducers are placed in order to record a signal as well as the collection of analog and digital filtering techniques used to further improve the signal quality. It also presents the wide array of methods and features used to characterize these signals, ranging from simply counting the number of swallows that occur over a period of time to calculating various descriptive features in the time, frequency, and phase space domains. Finally, this paper presents the algorithms that have been used to classify this data into ‘normal’ and ‘abnormal’ categories. Both linear as well as non-linear techniques are presented in this regard. PMID:26213659

  12. Bronchitis

    MedlinePlus

    ... you and listen to your chest with a stethoscope for signs of wheezing and congestion. In addition ... harder time recovering from acute bronchitis and other respiratory infections. Smoking causes lung damage in many ways. ...

  13. Pulmonary nocardiosis

    MedlinePlus

    ... you and listen to your lungs using a stethoscope. You may have abnormal lung sounds, called crackles. ... returning. Alternative Names Nocardiosis - pulmonary; Mycetoma; Nocardia Images Respiratory system References Southwick FS. Nocardiosis. In: Goldman L, ...

  14. Control Software

    NASA Technical Reports Server (NTRS)

    1997-01-01

    Real-Time Innovations, Inc. (RTI) collaborated with Ames Research Center, the Jet Propulsion Laboratory and Stanford University to leverage NASA research to produce ControlShell software. RTI is the first "graduate" of Ames Research Center's Technology Commercialization Center. The ControlShell system was used extensively on a cooperative project to enhance the capabilities of a Russian-built Marsokhod rover being evaluated for eventual flight to Mars. RTI's ControlShell is complex, real-time command and control software, capable of processing information and controlling mechanical devices. One ControlShell tool is StethoScope. As a real-time data collection and display tool, StethoScope allows a user to see how a program is running without changing its execution. RTI has successfully applied its software savvy in other arenas, such as telecommunications, networking, video editing, semiconductor manufacturing, automobile systems, and medical imaging.

  15. Present and Future Applications of Digital Electronics in Nuclear Science - a Commercial Prospective

    NASA Astrophysics Data System (ADS)

    Tan, Hui

    2011-10-01

    Digital readout electronics instrumenting radiation detectors have experienced significant advancements in the last decade or so. This on one hand can be attributed to the steady improvements in commercial digital processing components such as analog-to-digital converters (ADCs), digital-to-analog converters (DACs), field-programmable-gate-arrays (FPGAs), and digital-signal-processors (DSPs), and on the other hand can also be attributed to the increasing needs for improved time, position, and energy resolution in nuclear physics experiments, which have spurred the rapid development of commercial off-the-shelf high speed, high resolution digitizers or spectrometers. Absent from conventional analog electronics, the capability to record fast decaying pulses from radiation detectors in digital readout electronics has profoundly benefited nuclear physics researchers since they now can perform detailed pulse processing for applications such as gamma-ray tracking and decay-event selection and reconstruction. In this talk, present state-of-the-art digital readout electronics and its applications in a variety of nuclear science fields will be discussed, and future directions in hardware development for digital electronics will also be outlined, all from the prospective of a commercial manufacturer of digital electronics.

  16. Collapsed lung (pneumothorax)

    MedlinePlus

    ... provider will listen to your breathing with a stethoscope. If you have a collapsed lung, there are ... rupture, chest x-ray Pneumothorax - chest x-ray Respiratory system Chest tube insertion - series Pneumothorax - series References ...

  17. Meconium aspiration syndrome

    MedlinePlus

    ... will listen to the infant's chest with a stethoscope and may hear abnormal breath sounds, especially coarse, ... care - meconium Images Meconium References Crowley MA. Neonatal respiratory disorders. In: Martin RJ, Fanaroff AA, Walsh MC, ...

  18. Developing a Reference of Normal Lung Sounds in Healthy Peruvian Children

    PubMed Central

    Ellington, Laura E.; Emmanouilidou, Dimitra; Elhilali, Mounya; Gilman, Robert H.; Tielsch, James M.; Chavez, Miguel A.; Marin-Concha, Julio; Figueroa, Dante; West, James

    2018-01-01

    Purpose Lung auscultation has long been a standard of care for the diagnosis of respiratory diseases. Recent advances in electronic auscultation and signal processing have yet to find clinical acceptance; however, computerized lung sound analysis may be ideal for pediatric populations in settings, where skilled healthcare providers are commonly unavailable. We described features of normal lung sounds in young children using a novel signal processing approach to lay a foundation for identifying pathologic respiratory sounds. Methods 186 healthy children with normal pulmonary exams and without respiratory complaints were enrolled at a tertiary care hospital in Lima, Peru. Lung sounds were recorded at eight thoracic sites using a digital stethoscope. 151 (81 %) of the recordings were eligible for further analysis. Heavy-crying segments were automatically rejected and features extracted from spectral and temporal signal representations contributed to profiling of lung sounds. Results Mean age, height, and weight among study participants were 2.2 years (SD 1.4), 84.7 cm (SD 13.2), and 12.0 kg (SD 3.6), respectively; and, 47 % were boys. We identified ten distinct spectral and spectro-temporal signal parameters and most demonstrated linear relationships with age, height, and weight, while no differences with genders were noted. Older children had a faster decaying spectrum than younger ones. Features like spectral peak width, lower-frequency Mel-frequency cepstral coefficients, and spectro-temporal modulations also showed variations with recording site. Conclusions Lung sound extracted features varied significantly with child characteristics and lung site. A comparison with adult studies revealed differences in the extracted features for children. While sound-reduction techniques will improve analysis, we offer a novel, reproducible tool for sound analysis in real-world environments. PMID:24943262

  19. Developing a reference of normal lung sounds in healthy Peruvian children.

    PubMed

    Ellington, Laura E; Emmanouilidou, Dimitra; Elhilali, Mounya; Gilman, Robert H; Tielsch, James M; Chavez, Miguel A; Marin-Concha, Julio; Figueroa, Dante; West, James; Checkley, William

    2014-10-01

    Lung auscultation has long been a standard of care for the diagnosis of respiratory diseases. Recent advances in electronic auscultation and signal processing have yet to find clinical acceptance; however, computerized lung sound analysis may be ideal for pediatric populations in settings, where skilled healthcare providers are commonly unavailable. We described features of normal lung sounds in young children using a novel signal processing approach to lay a foundation for identifying pathologic respiratory sounds. 186 healthy children with normal pulmonary exams and without respiratory complaints were enrolled at a tertiary care hospital in Lima, Peru. Lung sounds were recorded at eight thoracic sites using a digital stethoscope. 151 (81%) of the recordings were eligible for further analysis. Heavy-crying segments were automatically rejected and features extracted from spectral and temporal signal representations contributed to profiling of lung sounds. Mean age, height, and weight among study participants were 2.2 years (SD 1.4), 84.7 cm (SD 13.2), and 12.0 kg (SD 3.6), respectively; and, 47% were boys. We identified ten distinct spectral and spectro-temporal signal parameters and most demonstrated linear relationships with age, height, and weight, while no differences with genders were noted. Older children had a faster decaying spectrum than younger ones. Features like spectral peak width, lower-frequency Mel-frequency cepstral coefficients, and spectro-temporal modulations also showed variations with recording site. Lung sound extracted features varied significantly with child characteristics and lung site. A comparison with adult studies revealed differences in the extracted features for children. While sound-reduction techniques will improve analysis, we offer a novel, reproducible tool for sound analysis in real-world environments.

  20. 47 CFR 101.503 - Digital Electronic Message Service Nodal Stations.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... 47 Telecommunication 5 2010-10-01 2010-10-01 false Digital Electronic Message Service Nodal... AND SPECIAL RADIO SERVICES FIXED MICROWAVE SERVICES 24 GHz Service and Digital Electronic Message Service § 101.503 Digital Electronic Message Service Nodal Stations. 10.6 GHz DEMS Nodal Stations may be...

  1. Doctor, Teacher, and Stethoscope: Neural Representation of Different Types of Semantic Relations.

    PubMed

    Xu, Yangwen; Wang, Xiaosha; Wang, Xiaoying; Men, Weiwei; Gao, Jia-Hong; Bi, Yanchao

    2018-03-28

    Concepts can be related in many ways. They can belong to the same taxonomic category (e.g., "doctor" and "teacher," both in the category of people) or be associated with the same event context (e.g., "doctor" and "stethoscope," both associated with medical scenarios). How are these two major types of semantic relations coded in the brain? We constructed stimuli from three taxonomic categories (people, manmade objects, and locations) and three thematic categories (school, medicine, and sports) and investigated the neural representations of these two dimensions using representational similarity analyses in human participants (10 men and nine women). In specific regions of interest, the left anterior temporal lobe (ATL) and the left temporoparietal junction (TPJ), we found that, whereas both areas had significant effects of taxonomic information, the taxonomic relations had stronger effects in the ATL than in the TPJ ("doctor" and "teacher" closer in ATL neural activity), with the reverse being true for thematic relations ("doctor" and "stethoscope" closer in TPJ neural activity). A whole-brain searchlight analysis revealed that widely distributed regions, mainly in the left hemisphere, represented the taxonomic dimension. Interestingly, the significant effects of the thematic relations were only observed after the taxonomic differences were controlled for in the left TPJ, the right superior lateral occipital cortex, and other frontal, temporal, and parietal regions. In summary, taxonomic grouping is a primary organizational dimension across distributed brain regions, with thematic grouping further embedded within such taxonomic structures. SIGNIFICANCE STATEMENT How are concepts organized in the brain? It is well established that concepts belonging to the same taxonomic categories (e.g., "doctor" and "teacher") share neural representations in specific brain regions. How concepts are associated in other manners (e.g., "doctor" and "stethoscope," which are thematically related) remains poorly understood. We used representational similarity analyses to unravel the neural representations of these different types of semantic relations by testing the same set of words that could be differently grouped by taxonomic categories or by thematic categories. We found that widely distributed brain areas primarily represented taxonomic categories, with the thematic categories further embedded within the taxonomic structure. Copyright © 2018 the authors 0270-6474/18/383303-15$15.00/0.

  2. Poststreptococcal glomerulonephritis (GN)

    MedlinePlus

    ... following: Decreased urine output Rust-colored urine Swelling (edema), general swelling, swelling of the abdomen, swelling of ... A physical examination shows swelling (edema), especially in the face. ... to the heart and lungs with a stethoscope. Blood pressure ...

  3. Apgar score

    MedlinePlus

    ... infant cries well, the respiratory score is 2. Heart rate is evaluated by stethoscope. This is the most important assessment: If there is no heartbeat, the infant scores 0 for heart rate. If heart rate is less than 100 ...

  4. Rene Theophile Hyacinthe Laënnec (1781–1826): The Man Behind the Stethoscope

    PubMed Central

    Roguin, Ariel

    2006-01-01

    Rene Theophile Hyacinthe Laënnec (1781–1826) was a French physician who, in 1816, invented the stethoscope. Using this new instrument, he investigated the sounds made by the heart and lungs and determined that his diagnoses were supported by the observations made during autopsies. Laënnec later published the first seminal work on the use of listening to body sounds, De L’auscultation Mediate (On Mediate Auscultation). Laënnec is considered the father of clinical auscultation and wrote the first descriptions of bronchiectasis and cirrhosis and also classified pulmonary conditions such as pneumonia, bronchiectasis, pleurisy, emphysema, pneumothorax, phthisis and other lung diseases from the sounds he heard with his invention. Laënnec perfected the art of physical examination of the chest and introduced many clinical terms still used today. PMID:17048358

  5. Fetal evaluation for transport by ultrasound performed by air medical teams: A case series.

    PubMed

    Polk, James D; Merlino, James I; Kovach, Betty L; Mancuso, Charlene; Fallon, William F

    2004-01-01

    The air medical team has limited options when evaluating the obstetrical patient and assessing fetal health during air transport to a high-risk obstetrical unit. Traditionally, physical examination and a Doppler stethoscope have been used to determine fetal heart rates and movement. However, with the advent of portable ultrasound technology, new information about the mother and child are available to the air medical crew. The Fetal Evaluation for Transport with Ultrasound (FETUS) is a screening examination that consists of an evaluation of the fetal heart rate, position, and movement and general condition of the placenta. The examination can be repeated in flight with no acoustic distortion from rotor noise. The additional information can be advantageous when transport decisions need to be made or when conditions do not allow Doppler stethoscope use.

  6. Fabrication and test of digital output interface devices for gas turbine electronic controls

    NASA Technical Reports Server (NTRS)

    Newirth, D. M.; Koenig, E. W.

    1978-01-01

    A program was conducted to develop an innovative digital output interface device, a digital effector with optical feedback of the fuel metering valve position, for future electronic controls for gas turbine engines. A digital effector (on-off solenoids driven directly by on-off signals from a digital electronic controller) with optical position feedback was fabricated, coupled with the fuel metering valve, and tested under simulated engine operating conditions. The testing indicated that a digital effector with optical position feedback is a suitable candidate, with proper development for future digital electronic gas turbine controls. The testing also identified several problem areas which would have to be overcome in a final production configuration.

  7. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2012-10-01 2012-10-01 false Digital electronic switching. 32.2212 Section...

  8. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2014-10-01 2014-10-01 false Digital electronic switching. 32.2212 Section...

  9. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2011-10-01 2011-10-01 false Digital electronic switching. 32.2212 Section...

  10. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2010-10-01 2010-10-01 false Digital electronic switching. 32.2212 Section...

  11. 47 CFR 32.2212 - Digital electronic switching.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... shall include the original cost of digital electronic switching equipment used to provide circuit... electronic switching equipment used to provide both circuit and packet switching shall be recorded in the... 47 Telecommunication 2 2013-10-01 2013-10-01 false Digital electronic switching. 32.2212 Section...

  12. NEW THORACIC MURMURS, WITH TWO NEW INSTRUMENTS, THE REFRACTOSCOPE AND THE PARTIAL STETHOSCOPE

    PubMed Central

    Parker, Frederick D.

    1918-01-01

    1. An understanding of the physics of sound is essential for a better comprehension of refined auscultation, tone analysis, and the use of these instruments. 2. The detection of variations of the third heart sound should prove a valuable aid in predicting mitral disease. 3. The variations of the outflow sound should prove a valuable aid in determining early aortic lesions with the type of accompanying intimal changes. 4. The character of chamber timbre as distinct from loudness heard as the first and second heart sounds denotes more often the condition of heart muscle, and must not be confounded with valvular disease. 5. The full significance of sound shadows is uncertain. Cardiac sound shadows appear normally in the right axilla and below the left clavicle. Their mode of production is quite clear. 6. Both the third heart sound and the outflow sound may be heard with the ordinary stethoscope. PMID:19868281

  13. 77 FR 68829 - Certain Electronic Digital Media Devices and Components Thereof; Notice of Request for Statements...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-16

    ... INTERNATIONAL TRADE COMMISSION [Investigation No. 337-TA-796] Certain Electronic Digital Media... electronic digital media devices and components thereof imported by respondents Samsung Electronics Co, Ltd... Samsung. FOR FURTHER INFORMATION CONTACT: Cathy Chen, Office of the General Counsel, U.S. International...

  14. Comparison of flight results with digital simulation for a digital electronic engine control in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Myers, L. P.; Burcham, F. W., Jr.

    1983-01-01

    Substantial benefits of a full authority digital electronic engine control on an air breathing engine were demonstrated repeatedly in simulation studies, ground engine tests, and engine altitude test facilities. A digital engine electronic control system showed improvements in efficiency, performance, and operation. An additional benefit of full authority digital controls is the capability of detecting and correcting failures and providing engine health diagnostics.

  15. Impact of the presence of medical equipment in images on viewers' perceptions of the trustworthiness of an individual on-screen.

    PubMed

    Jiwa, Moyez; Millett, Stephan; Meng, Xingqiong; Hewitt, Vivien M

    2012-07-10

    It is now common practice for doctors to consult patients by means other than face-to-face, often appearing before the patient on a computer screen. Also, many websites are using depictions of health professionals to increase the credibility of their services. Being trustworthy is an essential attribute for successful ehealth services. Little is known about which depicted accessories make a health professional appear more trustworthy. To estimate the odds of an individual on-screen being rated trustworthy when viewed in a static image holding or wearing specific items of medical equipment. We surveyed consecutive people attending community pharmacies to collect prescriptions in Western Australia. Respondents were presented with a series of 10 photographs, generated at random, of a man with varying numbers and combinations of medical equipment: stethoscope, reflex hammer, surgical scrubs, otoscope, and pen. They were then invited to rate the man as honest, trustworthy, honorable, moral, ethical, or genuine, or a combination of these, on the Source Credibility Scale. A total of 168 of 250 people gave informed consent, for a participation rate of 67.2%. There were 102 female and 66 male respondents. Of the 168 respondents, 96 (57%) were born in Australia and 102 (60.7%) were attending medical practices with more than one general practitioner. The mean age of respondents was 47 (SD 16) years (range 26-92 years). When only 1 item was present in an image, the stethoscope was associated with the highest odds for the person being considered honest (odds ratio [OR] 2.6, 95% confidence interval [CI] 1.6-4.3), trustworthy (OR 2.3, 95% CI 1.4-3.8), honorable (OR 2.7, 95% CI 1.6-4.5), moral (OR 2.4 95% CI 1.4-4.1), ethical (OR 2.6, 95% CI 1.5-4.6), and genuine (OR 1.8, 95% CI 1.0-3.1). The presence of a stethoscope increased the odds of the person being rated in a positive light in all photographs in which it was included. When an individual is portrayed in a static image, concurrent presentation of 3 or more items of medical equipment, and especially a stethoscope, is likely to exert a positive influence on the viewers' perceptions of the qualities of the person depicted.

  16. Application of a digital data acquisition system for time of flight Positron annihilation-induced Auger Electron Spectroscopy

    NASA Astrophysics Data System (ADS)

    Gladen, R. W.; Chirayath, V. A.; McDonald, A. D.; Fairchild, A. J.; Chrysler, M. D.; Imam, S. K.; Koymen, A. R.; Weiss, A. H.

    We describe herein a digital data acquisition system for a time-of-flight Positron annihilation-induced Auger Electron Spectrometer. This data acquisition system consists of a high-speed digitizer collecting signals induced by Auger electrons and annihilation gammas in a multi-channel plate electron detector and a BaF2 gamma detector, respectively. The time intervals between these two signals is used to determine the times of flight of the Auger electrons, which are analyzed by algorithms based on traditional nuclear electronics methods. Ultimately, this digital data acquisition system will be expanded to incorporate the first coincidence measurements of Auger electron and annihilation gamma energies.

  17. 21 CFR 1311.15 - Limitations on CSOS digital certificates.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 9 2011-04-01 2011-04-01 false Limitations on CSOS digital certificates. 1311.15... ELECTRONIC ORDERS AND PRESCRIPTIONS Obtaining and Using Digital Certificates for Electronic Orders § 1311.15 Limitations on CSOS digital certificates. (a) A CSOS digital certificate issued by the DEA Certification...

  18. 21 CFR 1311.15 - Limitations on CSOS digital certificates.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Limitations on CSOS digital certificates. 1311.15... ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) Obtaining and Using Digital Certificates for Electronic Orders § 1311.15 Limitations on CSOS digital certificates. (a) A CSOS digital certificate issued by the...

  19. Educational Gardening.

    ERIC Educational Resources Information Center

    Lovejoy, Sharon

    1998-01-01

    A naturalist and designer of public gardens relates her experiences of introducing children to plants and gardens using equipment such as binoculars, stethoscopes, notebooks, photographs, and magnifying glasses. Article provides information is given about many plants, their uses, and related child-centered activities (such as a namesake pumpkins…

  20. A description of externally recorded womb sounds in human subjects during gestation

    PubMed Central

    Daland, Robert; Kesavan, Kalpashri; Macey, Paul M.; Zeltzer, Lonnie; Harper, Ronald M.

    2018-01-01

    Objective Reducing environmental noise benefits premature infants in neonatal intensive care units (NICU), but excessive reduction may lead to sensory deprivation, compromising development. Instead of minimal noise levels, environments that mimic intrauterine soundscapes may facilitate infant development by providing a sound environment reflecting fetal life. This soundscape may support autonomic and emotional development in preterm infants. We aimed to assess the efficacy and feasibility of external non-invasive recordings in pregnant women, endeavoring to capture intra-abdominal or womb sounds during pregnancy with electronic stethoscopes and build a womb sound library to assess sound trends with gestational development. We also compared these sounds to popular commercial womb sounds marketed to new parents. Study design Intra-abdominal sounds from 50 mothers in their second and third trimester (13 to 40 weeks) of pregnancy were recorded for 6 minutes in a quiet clinic room with 4 electronic stethoscopes, placed in the right upper and lower quadrants, and left upper and lower quadrants of the abdomen. These recording were partitioned into 2-minute intervals in three different positions: standing, sitting and lying supine. Maternal and gestational age, Body Mass Index (BMI) and time since last meal were collected during recordings. Recordings were analyzed using long-term average spectral and waveform analysis, and compared to sounds from non-pregnant abdomens and commercially-marketed womb sounds selected for their availability, popularity, and claims they mimic the intrauterine environment. Results Maternal sounds shared certain common characteristics, but varied with gestational age. With fetal development, the maternal abdomen filtered high (500–5,000 Hz) and mid-frequency (100–500 Hz) energy bands, but no change appeared in contributions from low-frequency signals (10–100 Hz) with gestational age. Variation appeared between mothers, suggesting a resonant chamber role for intra-abdominal space. Compared to commercially-marketed sounds, womb signals were dominated by bowel sounds, were of lower frequency, and showed more variation in intensity. Conclusions High-fidelity intra-abdominal or womb sounds during pregnancy can be recorded non-invasively. Recordings vary with gestational age, and show a predominance of low frequency noise and bowel sounds which are distinct from popular commercial products. Such recordings may be utilized to determine whether sounds influence preterm infant development in the NICU. PMID:29746604

  1. A description of externally recorded womb sounds in human subjects during gestation.

    PubMed

    Parga, Joanna J; Daland, Robert; Kesavan, Kalpashri; Macey, Paul M; Zeltzer, Lonnie; Harper, Ronald M

    2018-01-01

    Reducing environmental noise benefits premature infants in neonatal intensive care units (NICU), but excessive reduction may lead to sensory deprivation, compromising development. Instead of minimal noise levels, environments that mimic intrauterine soundscapes may facilitate infant development by providing a sound environment reflecting fetal life. This soundscape may support autonomic and emotional development in preterm infants. We aimed to assess the efficacy and feasibility of external non-invasive recordings in pregnant women, endeavoring to capture intra-abdominal or womb sounds during pregnancy with electronic stethoscopes and build a womb sound library to assess sound trends with gestational development. We also compared these sounds to popular commercial womb sounds marketed to new parents. Intra-abdominal sounds from 50 mothers in their second and third trimester (13 to 40 weeks) of pregnancy were recorded for 6 minutes in a quiet clinic room with 4 electronic stethoscopes, placed in the right upper and lower quadrants, and left upper and lower quadrants of the abdomen. These recording were partitioned into 2-minute intervals in three different positions: standing, sitting and lying supine. Maternal and gestational age, Body Mass Index (BMI) and time since last meal were collected during recordings. Recordings were analyzed using long-term average spectral and waveform analysis, and compared to sounds from non-pregnant abdomens and commercially-marketed womb sounds selected for their availability, popularity, and claims they mimic the intrauterine environment. Maternal sounds shared certain common characteristics, but varied with gestational age. With fetal development, the maternal abdomen filtered high (500-5,000 Hz) and mid-frequency (100-500 Hz) energy bands, but no change appeared in contributions from low-frequency signals (10-100 Hz) with gestational age. Variation appeared between mothers, suggesting a resonant chamber role for intra-abdominal space. Compared to commercially-marketed sounds, womb signals were dominated by bowel sounds, were of lower frequency, and showed more variation in intensity. High-fidelity intra-abdominal or womb sounds during pregnancy can be recorded non-invasively. Recordings vary with gestational age, and show a predominance of low frequency noise and bowel sounds which are distinct from popular commercial products. Such recordings may be utilized to determine whether sounds influence preterm infant development in the NICU.

  2. Design reflowable digital book template

    NASA Astrophysics Data System (ADS)

    Prasetya, Didik Dwi; Widiyaningtyas, Triyanna; Arifin, M. Zainal; Wahyu Sakti G., I.

    2017-09-01

    Electronic books (e-books or digital books) increasingly in demand and continue to grow in the form of future books. One of the standard format electronic books that potential is EPUB (electronic publication) published by the International Digital Publishing Forum (IDPF). This digital book has major advantages are able to provide interactive and reflowable content, which are not found in another book format, such as PDF. Reflowable content allows the book can be accessed through a variety of reader device, like desktop and mobile with a fit and comfort view. However, because the generating process of an EPUB digital book is not as easy a PDF, so this format is less popular. Therefore, in order to help overcome the existing problems, this paper develops digital reflowable text book templates to support electronic learning, especially in Indonesia. This template can be used by anyone to produce a standard digital book quickly and easily without requiring additional specialized knowledge.

  3. Comparison between Two Endotracheal Tube Cuff Inflation Methods; Just-Seal Vs. Stethoscope-Guided.

    PubMed

    Borhazowal, Rishiraj; Harde, Minal; Bhadade, Rakesh; Dave, Sona; Aswar, Swapnil Ganeshrao

    2017-06-01

    The Endotracheal Tube (ETT) cuff performs a critical function of sealing the airway during positive pressure ventilation. There is a narrow range of cuff pressure required to maintain a functionally safe seal without exceeding capillary blood pressure. We aimed to compare Just-Seal (JS) and Stethoscope-Guided (SG) method of ETT cuff inflation with respect to the volume of air required to inflate the cuff, the manometric cuff pressure achieved and also to assess for the occurrence of postoperative sore throat after extubation in both the groups. It was a prospective observational study done in a Tertiary Teaching Public Hospital over a period of 1½ years on 100 patients with 50 each in two groups; JS or SG method of cuff inflation. SPSS Version 17 was used for data analysis. Statistically significant difference (p-value of less than 0.05) was noted between the two methods based on the volume of air injected into the cuff {the mean volume injected in JS was 6.79 ml and in the SG was 4.95 ml with p=5.71E-16 (< 0.05)} and cuff pressure achieved {mean cuff pressure achieved was 38.80 cm H 2 O in the JS and 29.64 cm H 2 O in SG with p=2.29E-14 (< 0.05)}. The incidence of post extubation sore throat was 54% (27 in 50) in the JS group and only 12% (6 in 50) in the SG; p= 0.00000797. ETT cuff inflation guided by a stethoscope is an effective technique for ensuring appropriate cuff pressures thus accomplishing the objective of providing safe and superior quality care of the patient both during and after anaesthesia and reducing the likelihood of even minimal risk complications that may still have legal implications.

  4. 27 CFR 73.3 - What terms must I know to understand this part?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... and/or actions are both unique to that individual and measurable. Digital signature. An electronic... verified. A signer creates a digital signature by using public-key encryption to transform a message digest of an electronic message. If a recipient of the digital signature has an electronic message, message...

  5. 27 CFR 73.3 - What terms must I know to understand this part?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... and/or actions are both unique to that individual and measurable. Digital signature. An electronic... verified. A signer creates a digital signature by using public-key encryption to transform a message digest of an electronic message. If a recipient of the digital signature has an electronic message, message...

  6. Unvoiced Speech Recognition Using Tissue-Conductive Acoustic Sensor

    NASA Astrophysics Data System (ADS)

    Heracleous, Panikos; Kaino, Tomomi; Saruwatari, Hiroshi; Shikano, Kiyohiro

    2006-12-01

    We present the use of stethoscope and silicon NAM (nonaudible murmur) microphones in automatic speech recognition. NAM microphones are special acoustic sensors, which are attached behind the talker's ear and can capture not only normal (audible) speech, but also very quietly uttered speech (nonaudible murmur). As a result, NAM microphones can be applied in automatic speech recognition systems when privacy is desired in human-machine communication. Moreover, NAM microphones show robustness against noise and they might be used in special systems (speech recognition, speech transform, etc.) for sound-impaired people. Using adaptation techniques and a small amount of training data, we achieved for a 20 k dictation task a[InlineEquation not available: see fulltext.] word accuracy for nonaudible murmur recognition in a clean environment. In this paper, we also investigate nonaudible murmur recognition in noisy environments and the effect of the Lombard reflex on nonaudible murmur recognition. We also propose three methods to integrate audible speech and nonaudible murmur recognition using a stethoscope NAM microphone with very promising results.

  7. Endotracheal tube leak pressure and tracheal lumen size in swine.

    PubMed

    Finholt, D A; Audenaert, S M; Stirt, J A; Marcella, K L; Frierson, H F; Suddarth, L T; Raphaely, R C

    1986-06-01

    Endotracheal tube "leak" is often estimated in children to judge the fit of uncuffed endotracheal tubes within the trachea. Twenty-five swine were intubated with uncuffed tracheal tubes to determine whether a more sensitive measurement of leaks could be devised and whether leak pressure estimates fit between tracheal tube and trachea. We compared leak pressure measurement using a stethoscope and aneroid manometer with a technique using a microphone, pressure transducer, and recorder, and found no differences between the two methods. The tracheas were then removed and slides prepared of tracheal cross-sectional specimens. Regression analysis revealed a linear relationship between tracheal lumen size and tracheal tube size for both low leak pressure (y = -0.4 + 0.79x, r = 0.88, P less than 0.05) and high leak pressure (y = -2.9 + 0.71x, r = 0.92, P less than 0.05) groups. We conclude that leak testing with a stethoscope and aneroid manometer is sensitive and accurate, and that tracheal tube leak pressure accurately portrays fit between tube and trachea.

  8. 21 CFR 1311.50 - Requirements for recipients of digitally signed orders.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... REQUIREMENTS FOR ELECTRONIC ORDERS AND PRESCRIPTIONS Obtaining and Using Digital Certificates for Electronic... digital certificate has not expired by checking the expiration date against the date the order was signed...

  9. 21 CFR 1311.35 - Number of CSOS digital certificates needed.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 9 2011-04-01 2011-04-01 false Number of CSOS digital certificates needed. 1311... FOR ELECTRONIC ORDERS AND PRESCRIPTIONS Obtaining and Using Digital Certificates for Electronic Orders § 1311.35 Number of CSOS digital certificates needed. A purchaser of Schedule I and II controlled...

  10. 21 CFR 1311.20 - Coordinators for CSOS digital certificate holders.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Coordinators for CSOS digital certificate holders... REQUIREMENTS FOR ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) Obtaining and Using Digital Certificates for Electronic Orders § 1311.20 Coordinators for CSOS digital certificate holders. (a) Each registrant...

  11. Initial Field Test of a Cloud-Based Cardiac Auscultation System to Determine Murmur Etiology in Rural China.

    PubMed

    Pyles, Lee; Hemmati, Pouya; Pan, J; Yu, Xiaoju; Liu, Ke; Wang, Jing; Tsakistos, Andreas; Zheleva, Bistra; Shao, Weiguang; Ni, Quan

    2017-04-01

    A system for collection, distribution, and long distant, asynchronous interpretation of cardiac auscultation has been developed and field-tested in rural China. We initiated a proof-of-concept test as a critical component of design of a system to allow rural physicians with little experience in evaluation of congenital heart disease (CHD) to obtain assistance in diagnosis and management of children with significant heart disease. The project tested the hypothesis that acceptable screening of heart murmurs could be accomplished using a digital stethoscope and internet cloud transmittal to deliver phonocardiograms to an experienced observer. Of the 7993 children who underwent school-based screening in the Menghai District of Yunnan Province, Peoples Republic of China, 149 had a murmur noted by a screener. They had digital heart sounds and phonocardiograms collected with the HeartLink tele auscultation system, and underwent echocardiography by a cardiology resident from the First Affiliated Hospital of Kunming Medical University. The digital phonocardiograms, stored on a cloud server, were later remotely reviewed by a board-certified American pediatric cardiologist. Fourteen of these subjects were found to have CHD confirmed by echocardiogram. Using the HeartLink system, the pediatric cardiologist identified 11 of the 14 subjects with pathological murmurs, and missed three subjects with atrial septal defects, which were incorrectly identified as venous hum or Still's murmur. In addition, ten subjects were recorded as having pathological murmurs, when no CHD was confirmed by echocardiography during the field study. The overall test accuracy was 91% with 78.5% sensitivity and 92.6% specificity. This proof-of-concept study demonstrated the feasibility of differentiating pathologic murmurs due to CHD from normal functional heart murmurs with the HeartLink system. This field study is an initial step to develop a cost-effective CHD screening strategy in low-resource settings with a shortage of trained medical professionals and pediatric heart programs.

  12. The Salmonella Mutagenicity Assay: The Stethoscope of Genetic Toxicology for the 21 st Century

    EPA Science Inventory

    OBJECTIVES: According to the 2007 National Research Council report Toxicology for the Twenty-first Century, modem methods ("omics," in vitro assays, high-throughput testing, computational methods, etc.) will lead to the emergence of a new approach to toxicology. The Salmonella ma...

  13. 21 CFR 1311.35 - Number of CSOS digital certificates needed.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Number of CSOS digital certificates needed. 1311... FOR ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) Obtaining and Using Digital Certificates for Electronic Orders § 1311.35 Number of CSOS digital certificates needed. A purchaser of Schedule I and II...

  14. 21 CFR 1311.10 - Eligibility to obtain a CSOS digital certificate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Eligibility to obtain a CSOS digital certificate... REQUIREMENTS FOR ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) Obtaining and Using Digital Certificates for Electronic Orders § 1311.10 Eligibility to obtain a CSOS digital certificate. The following persons are...

  15. 21 CFR 1311.40 - Renewal of CSOS digital certificates.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Renewal of CSOS digital certificates. 1311.40... ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) Obtaining and Using Digital Certificates for Electronic Orders § 1311.40 Renewal of CSOS digital certificates. (a) A CSOS certificate holder must generate a new...

  16. 21 CFR 1311.25 - Requirements for obtaining a CSOS digital certificate.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 9 2010-04-01 2010-04-01 false Requirements for obtaining a CSOS digital... REQUIREMENTS FOR ELECTRONIC ORDERS AND PRESCRIPTIONS (Eff. 6-1-10) Obtaining and Using Digital Certificates for Electronic Orders § 1311.25 Requirements for obtaining a CSOS digital certificate. (a) To obtain a...

  17. The Ottawa telehealth project.

    PubMed

    Cheung, S T; Davies, R F; Smith, K; Marsh, R; Sherrard, H; Keon, W J

    1998-01-01

    To examine the telehealth system as a means of improving access to cardiac consultations and specialized health services in remote areas of Ontario. The University of Ottawa Heart Institute has set up a telehealth test program, Healthcare and Education Access for Remote Residents by Telecommunications (HEARRT), in collaboration with industry and the provincial and federal government, as well as several remote clinical test sites. The program makes off-site cardiology consultations possible. History taking and physical examinations are conducted by video and electronic stethoscope. Laboratory results and echocardiograms are transmitted by document camera and VCR. The technology is being tested in both stable outpatient and emergency situations. Various telecommunications bandwidths and encoding systems are being evaluated, including satellite and terrestrial-based asynchronous transfer-mode circuits. Patient satisfaction and cost-effectiveness are also being assessed. Bandwidths from as low as 384 kbps using H.320 encoders to 40 Mbps using digital transport of NTSC video signals have been evaluated. Although lower bandwidths are sufficient for sending echocardiographic and electrocardiogram data, bandwidths with transport speeds of 4 to 6 Mbps appear necessary to capture the nuances of the cardiac physical examination. A preliminary satisfaction survey of 19 patients noted that all felt that they could communicate effectively with the cardiologist by video, and each had confidence in the advice offered. None reported that he or she would rather have traveled to the doctor in person. Initial and projected examination of the costs suggested that telehealth will effectively reduce overall health care spending while decreasing travel expenses for rural patients. Telehealth technology is sufficiently sophisticated to allow off-site cardiology assessments. Preliminary results suggest there is a sound business case for the implementation of telehealth technology to meet the needs of remote residents in northern Ontario. Working closely with government and industry, we will develop a marketing and commercialization plan to support the use of this technology throughout Ontario and expand application to patient education and continuing medical education.

  18. Detection of boundary-layer transitions in wind tunnels

    NASA Technical Reports Server (NTRS)

    Wood, W. R.; Somers, D. M.

    1978-01-01

    Accelerometer replaces stethoscope in technique for detection of laminar-to-turbulent boundary-layer transitions on wind-tunnel models. Technique allows measurements above or below atmospheric pressure because human operator is not required within tunnel. Data may be taken from accelerometer, and pressure transducer simultaneously, and delivered to systems for analysis.

  19. 17 CFR 23.202 - Daily trading records.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ..., instant messaging, chat rooms, electronic mail, mobile device, or other digital or electronic media. Such...; (ii) Moneys borrowed and moneys loaned; (iii) The daily calculation of the value of each outstanding... rooms, electronic mail, mobile device, or other digital or electronic media; (2) Reliable timing data...

  20. 17 CFR 23.202 - Daily trading records.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., instant messaging, chat rooms, electronic mail, mobile device, or other digital or electronic media. Such...; (ii) Moneys borrowed and moneys loaned; (iii) The daily calculation of the value of each outstanding... rooms, electronic mail, mobile device, or other digital or electronic media; (2) Reliable timing data...

  1. The Integrity of Digital Information: Mechanics and Definitional Issues.

    ERIC Educational Resources Information Center

    Lynch, Clifford A.

    1994-01-01

    Considers issues regarding the migration of a system of literature into electronic formats. Highlights include integrity in an information distribution system; digest technology; tracings that permit detection of copied digital objects; verifying sources; digital signature technology and cryptography; electronic publishing; and intellectual…

  2. 77 FR 50726 - Software Requirement Specifications for Digital Computer Software and Complex Electronics Used in...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... Computer Software and Complex Electronics Used in Safety Systems of Nuclear Power Plants AGENCY: Nuclear...-1209, ``Software Requirement Specifications for Digital Computer Software and Complex Electronics used... Electronics Engineers (ANSI/IEEE) Standard 830-1998, ``IEEE Recommended Practice for Software Requirements...

  3. Fundamentals handbook of electrical and computer engineering. Volume 1 Circuits fields and electronics

    NASA Astrophysics Data System (ADS)

    Chang, S. S. L.

    State of the art technology in circuits, fields, and electronics is discussed. The principles and applications of these technologies to industry, digital processing, microwave semiconductors, and computer-aided design are explained. Important concepts and methodologies in mathematics and physics are reviewed, and basic engineering sciences and associated design methods are dealt with, including: circuit theory and the design of magnetic circuits and active filter synthesis; digital signal processing, including FIR and IIR digital filter design; transmission lines, electromagnetic wave propagation and surface acoustic wave devices. Also considered are: electronics technologies, including power electronics, microwave semiconductors, GaAs devices, and magnetic bubble memories; digital circuits and logic design.

  4. Electronic health record meets digital library: a new environment for achieving an old goal.

    PubMed

    Humphreys, B L

    2000-01-01

    Linking the electronic health record to the digital library is a Web-era reformulation of the long-standing informatics goal of seamless integration of automated clinical data and relevant knowledge-based information to support informed decisions. The spread of the Internet, the development of the World Wide Web, and converging format standards for electronic health data and digital publications make effective linking increasingly feasible. Some existing systems link electronic health data and knowledge-based information in limited settings or limited ways. Yet many challenging informatics research problems remain to be solved before flexible and seamless linking becomes a reality and before systems become capable of delivering the specific piece of information needed at the time and place a decision must be made. Connecting the electronic health record to the digital library also requires positive resolution of important policy issues, including health data privacy, government encouragement of high-speed communications, electronic intellectual property rights, and standards for health data and for digital libraries. Both the research problems and the policy issues should be important priorities for the field of medical informatics.

  5. Electronic Health Record Meets Digital Library

    PubMed Central

    Humphreys, Betsy L.

    2000-01-01

    Linking the electronic health record to the digital library is a Web-era reformulation of the long-standing informatics goal of seamless integration of automated clinical data and relevant knowledge-based information to support informed decisions. The spread of the Internet, the development of the World Wide Web, and converging format standards for electronic health data and digital publications make effective linking increasingly feasible. Some existing systems link electronic health data and knowledge-based information in limited settings or limited ways. Yet many challenging informatics research problems remain to be solved before flexible and seamless linking becomes a reality and before systems become capable of delivering the specific piece of information needed at the time and place a decision must be made. Connecting the electronic health record to the digital library also requires positive resolution of important policy issues, including health data privacy, government envouragement of high-speed communications, electronic intellectual property rights, and standards for health data and for digital libraries. Both the research problems and the policy issues should be important priorities for the field of medical informatics. PMID:10984463

  6. What Do Digital Books Mean for Libraries?

    ERIC Educational Resources Information Center

    Lynch, Clifford

    2001-01-01

    Discusses digital books, or electronic books, and their relationship to libraries and communication between authors and readers. Topics include the scholarly market, for academic libraries, versus the consumer market; textbooks versus novels; digitization of older books; marketing; costs; and electronic books versus printed books. (LRW)

  7. Highly integrated digital electronic control: Digital flight control, aircraft model identification, and adaptive engine control

    NASA Technical Reports Server (NTRS)

    Baer-Riedhart, Jennifer L.; Landy, Robert J.

    1987-01-01

    The highly integrated digital electronic control (HIDEC) program at NASA Ames Research Center, Dryden Flight Research Facility is a multiphase flight research program to quantify the benefits of promising integrated control systems. McDonnell Aircraft Company is the prime contractor, with United Technologies Pratt and Whitney Aircraft, and Lear Siegler Incorporated as major subcontractors. The NASA F-15A testbed aircraft was modified by the HIDEC program by installing a digital electronic flight control system (DEFCS) and replacing the standard F100 (Arab 3) engines with F100 engine model derivative (EMD) engines equipped with digital electronic engine controls (DEEC), and integrating the DEEC's and DEFCS. The modified aircraft provides the capability for testing many integrated control modes involving the flight controls, engine controls, and inlet controls. This paper focuses on the first two phases of the HIDEC program, which are the digital flight control system/aircraft model identification (DEFCS/AMI) phase and the adaptive engine control system (ADECS) phase.

  8. An Educational Laboratory for Digital Control and Rapid Prototyping of Power Electronic Circuits

    ERIC Educational Resources Information Center

    Choi, Sanghun; Saeedifard, M.

    2012-01-01

    This paper describes a new educational power electronics laboratory that was developed primarily to reinforce experimentally the fundamental concepts presented in a power electronics course. The developed laboratory combines theoretical design, simulation studies, digital control, fabrication, and verification of power-electronic circuits based on…

  9. Detecting regional lung properties using audio transfer functions of the respiratory system.

    PubMed

    Mulligan, K; Adler, A; Goubran, R

    2009-01-01

    In this study, a novel instrument has been developed for measuring changes in the distribution of lung fluid the respiratory system. The instrument consists of a speaker that inputs a 0-4kHz White Gaussian Noise (WGN) signal into a patient's mouth and an array of 4 electronic stethoscopes, linked via a fully adjustable harness, used to recover signals on the chest surface. The software system for processing the data utilizes the principles of adaptive filtering in order to obtain a transfer function that represents the input-output relationship for the signal as the volume of fluid in the lungs is varied. A chest phantom model was constructed to simulate the behavior of fluid related diseases within the lungs through the injection of varying volumes of water. Tests from the phantom model were compared to healthy subjects. Results show the instrument can obtain similar transfer functions and sound propagation delays between both human and phantom chests.

  10. A French national research project to the creation of an auscultation's school: the ASAP project.

    PubMed

    Andrès, Emmanuel; Reichert, Sandra; Gass, Raymond; Brandt, Christian

    2009-05-01

    Auscultation of pulmonary sounds provides valuable clinical information but has been regarded as a tool of low diagnostic value due to the inherent subjectivity in the evaluation of these sounds. This paper describes an ambitious study of in the so-called ASAP project or "Analyse de Sons Auscultatoires et Pathologiques". ASAP is a 3-year-long French collaborative project developed in the context of the News Technologies of Information and Communication. ASAP aims at making evolve the auscultation technics: by 1) the development objective tools for the analyse of auscultation sounds: electronic stethoscopes paired with computing device; 2) the creation of an auscultation sounds' database in order to compare and identify the acoustical and visual signatures of the pathologies; and 3) the capitalisation of these new auscultation techniques around the creation of a teaching unit: "Ecole de l'Auscultation". This auscultation's school will be destined to the initial and continuous formation of the medical attendants.

  11. An ultra-sensitive wearable accelerometer for continuous heart and lung sound monitoring.

    PubMed

    Hu, Yating; Xu, Yong

    2012-01-01

    This paper presents a chest-worn accelerometer with high sensitivity for continuous cardio-respiratory sound monitoring. The accelerometer is based on an asymmetrical gapped cantilever which is composed of a bottom mechanical layer and a top piezoelectric layer separated by a gap. This novel structure helps to increase the sensitivity by orders of magnitude compared with conventional cantilever based accelerometers. The prototype with a resonant frequency of 1100Hz and a total weight of 5 gram is designed, constructed and characterized. The size of the prototype sensor is 35mm×18mm×7.8mm (l×w×t). A built-in charge amplifier is used to amplify the output voltage of the sensor. A sensitivity of 86V/g and a noise floor of 40ng/√Hz are obtained. Preliminary tests for recording both cardiac and respiratory signals are carried out on human body and the new sensor exhibits better performance compared with a high-end electronic stethoscope.

  12. F-15 digital electronic engine control system description

    NASA Technical Reports Server (NTRS)

    Myers, L. P.

    1984-01-01

    A digital electronic engine control (DEEC) was developed for use on the F100-PW-100 turbofan engine. This control system has full authority control, capable of moving all the controlled variables over their full ranges. The digital computational electronics and fault detection and accomodation logic maintains safe engine operation. A hydromechanical backup control (BUC) is an integral part of the fuel metering unit and provides gas generator control at a reduced performance level in the event of an electronics failure. The DEEC's features, hardware, and major logic diagrams are described.

  13. Survey of Physical Assessment Course Offerings in American Colleges of Pharmacy.

    ERIC Educational Resources Information Center

    da Camara, Carlos C.; And Others

    1996-01-01

    A survey of 55 pharmacy schools found that of those offering a pharmacy doctoral program, three-fourths had a separate course devoted to physical assessment of patients, most offered in the third professional year. Most require students to demonstrate use of stethoscope, sphygmomanometer, ophthalmo-otoscope, tuning fork, reflex hammer. Reasons for…

  14. Phonocardiography with a smartphone

    NASA Astrophysics Data System (ADS)

    Thoms, Lars-Jochen; Colicchia, Giuseppe; Girwidz, Raimund

    2017-03-01

    When a stethoscope is placed on the chest over the heart, sounds coming from the heart can be directly heard. These sound vibrations can be captured through a microphone and the electrical signals from the transducer can be processed and plotted in a phonocardiogram. Students can easily use a microphone and smartphone to capture and analyse characteristic heart sounds.

  15. Phonocardiography with a Smartphone

    ERIC Educational Resources Information Center

    Thoms, Lars-Jochen; Colicchia, Giuseppe; Girwidz, Raimund

    2017-01-01

    When a stethoscope is placed on the chest over the heart, sounds coming from the heart can be directly heard. These sound vibrations can be captured through a microphone and the electrical signals from the transducer can be processed and plotted in a phonocardiogram. Students can easily use a microphone and smartphone to capture and analyse…

  16. Performance of the Fully Digital FPGA-Based Front-End Electronics for the GALILEO Array

    NASA Astrophysics Data System (ADS)

    Barrientos, D.; Bellato, M.; Bazzacco, D.; Bortolato, D.; Cocconi, P.; Gadea, A.; González, V.; Gulmini, M.; Isocrate, R.; Mengoni, D.; Pullia, A.; Recchia, F.; Rosso, D.; Sanchis, E.; Toniolo, N.; Ur, C. A.; Valiente-Dobón, J. J.

    2015-12-01

    In this work we present the architecture and results of a fully digital Front End Electronics (FEE) read out system developed for the GALILEO array. The FEE system, developed in collaboration with the Advanced Gamma Tracking Array (AGATA) collaboration, is composed of three main blocks: preamplifiers, digitizers and preprocessing electronics. The slow control system contains a custom Linux driver, a dynamic library and a server implementing network services. This work presents the first results of the digital FEE system coupled with a GALILEO germanium detector, which has demonstrated the capability to achieve an energy resolution of 1.530/00 at an energy of 1.33 MeV, similar to the one obtained with a conventional analog system. While keeping a good performance in terms of energy resolution, digital electronics will allow to instrument the full GALILEO array with a versatile system with high integration and low power consumption and costs.

  17. Assessment of children for acute respiratory infections in hospital outpatients in Tanzania: what drives good practice?

    PubMed

    Chandler, Clare I R; Nadjm, Behzad; Boniface, Gloria; Juma, Kaseem; Reyburn, Hugh; Whitty, Christopher J M

    2008-12-01

    Respiratory infections cause significant mortality in developing countries but are frequently undiagnosed. Reasons for this are unclear. We observed 1,081 outpatient consultations with patients less than five years of age in Tanzania. In 554 patients with cough or difficulty breathing, the absolute percentages examined were 5% for respiratory rate counted, 14% chest exposed, and 25% stethoscope used. Decisions to conduct particular examinations did appear to follow clinical logic, with odds ratios of 4.28 for counting respiratory rate (95% confidence interval [CI]=1.75-10.47), 2.57 for exposing the chest (95% CI=1.67-3.95), and 18.91 for using a stethoscope (95% CI=9.52-37.57) in patients with cough or difficulty breathing. Non-clinical variables, including salary level, were also associated with examinations, and history taking was more common among clinicians originating outside the hospital area. Although respiratory examinations are relatively more common in those with cough or difficulty breathing, the absolute rates are low and related to non-clinical and clinical factors.

  18. Current Total Ionizing Dose Results and Displacement Damage Results for Candidate Spacecraft Electronics for NASA

    NASA Technical Reports Server (NTRS)

    Cochran, Donna J.; Kniffin, Scott D.; LaBel, Kenneth A.; OBryan, Martha V.; Reed, Robert A.; Ladbury, Ray L.; Howard, James W., Jr.; Poivey, Christian; Buchner, Stephen P.; Marshall, Cheryl J.

    2004-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to-Digital Converters (ADCs), and Digital-to-Analog Converters (DACS), among others.

  19. Total Ionizing Dose Results and Displacement Damage Results for Candidate Spacecraft Electronics for NASA

    NASA Technical Reports Server (NTRS)

    Cochran, Donna J.; Kniffin, Scott D.; LaBel, Kenneth A.; OBryan, Martha V.; Reed, Robert A.; Ladbury, Ray L.; Howard, James W., Jr.; Poivey, Christian; Buchner, Stephen P.; Marshall, Cheryl J.

    2003-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to-Digital Converters (ADCs), and Digital-to-Analog Converters (DACs), among others.

  20. NASA researchers in gold control room during an F-15 HiDEC flight

    NASA Technical Reports Server (NTRS)

    1993-01-01

    NASA researchers monitor equipment in the mission control Gold room at the Dryden Flight Research Center, Edwards, California, during a flight of an F-15 Highly Integrated Digital Electronic Control (HIDEC) research aircraft. The system was developed on the F-15 to investigate and demonstrate methods of obtaining optimum aircraft performance. The major elements of HIDEC were a Digital Electronic Flight Control System (DEFCS), a Digital Electronic Engine Control (DEEC), an on-board general purpose computer, and an integrated architecture to allow all components to 'talk to each other.' Unlike standard F-15s, which have a mechanical and analog electronic flight control system, the HIDEC F-15 also had a dual-channel, fail-safe digital flight control system programmed in Pascal. It was linked to the Military Standard 1553B and a H009 data bus which tied all the other electronic systems together.

  1. NASA researchers in gold control room during an F-15 HiDEC flight, John Orme and Gerard Schkolnik

    NASA Technical Reports Server (NTRS)

    1993-01-01

    NASA researchers Gerard Schkolnik (left) and John Orme monitor equipment in the control room at the Dryden Flight Research Center, Edwards, California, during a flight of an F-15 Highly Integrated Digital Electronic Control (HIDEC) research aircraft. The system was developed on the F-15 to investigate and demonstrate methods of obtaining optimum aircraft performance. The major elements of HIDEC were a Digital Electronic Flight Control System (DEFCS), a Digital Electronic Engine Control (DEEC), an on-board general purpose computer, and an integrated architecture to allow all components to 'talk to each other.' Unlike standard F-15s, which have a mechanical and analog electronic flight control system, the HIDEC F-15 also had a dual-channel, fail-safe digital flight control system programmed in Pascal. It was linked to the Military Standard 1553B and a H009 data bus which tied all the other electronic systems together.

  2. ERM Ideas and Innovations: Digital Repository Management as ERM

    ERIC Educational Resources Information Center

    Pinkas, María M.; Lin, Na

    2014-01-01

    This article describes the application of electronic resources management (ERM) to digital repository management at the Health Sciences and Human Services Library at the University of Maryland, Baltimore. The authors discuss electronic resources management techniques, through the application of "Techniques for Electronic Management,"…

  3. Recent Total Ionizing Dose Results and Displacement Damage Results for Candidate Spacecraft Electronics for NASA

    NASA Technical Reports Server (NTRS)

    Cochran, Donna J.; Buchner, Stephen P.; Irwin, Tim L.; LaBel, Kenneth A.; Marshall, Cheryl J.; Reed, Robert A.; Sanders, Anthony B.; Hawkins, Donald K.; Flanigan, Ryan J.; Cox, Stephen R.

    2005-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to total ionizing dose and displacement damage. Devices tested include optoelectronics, digital, analog, linear bipolar devices, hybrid devices, Analog-to- Digital Converters (ADCs), and Digital-to-Analog Converters (DACs), among others. T

  4. Carotid artery ultrasonographic assessment in patients from the Fremantle Diabetes Study Phase II with carotid bruits detected by electronic auscultation.

    PubMed

    Knapp, Arthur; Cetrullo, Violetta; Sillars, Brett A; Lenzo, Nat; Davis, Wendy A; Davis, Timothy M E

    2014-09-01

    Electronic auscultation appears superior to acoustic auscultation for identifying hemodynamic abnormalities. The aim of this study was to determine whether carotid bruits detected by electronic stethoscope in patients with diabetes are associated with stenoses and increased carotid intima-medial thickness (CIMT). Fifty Fremantle Diabetes Study patients (mean±SD age, 73.7±10.0 years; 38.0% males) with a bruit found by electronic auscultation and 50 age- and sex-matched patients with normal carotid sounds were studied. The degree of stenosis and CIMT were assessed from duplex ultrasonography. Patients with a bruit were more likely to have stenosis of ≥50% and CIMT of >1.0 mm than those without (odds ratios [95% confidence intervals]=14.0 [1.8-106.5] and 5.3 [1.8-15.3], respectively; both P=0.001). For the six patients with stenosis of ≥70%, five had a bruit, and one (with a known total occlusion) did not (odds ratio=5.0 [0.6-42.8]; P=0.22). The sensitivity and specificity of carotid bruit for stenoses of ≥50% were 88% and 58%, respectively; respective values for stenoses of ≥70% were 83% and 52%. The equivalent negative predictive values were 96% and 98%, and positive predictive values were 30% and 10%, respectively. Electronic recording of carotid sounds for later interpretation is convenient and reliable. Most patients with stenoses had an overlying bruit. Most bruits were false positives, but ultrasonography is justified to document extent of disease; CIMT measurement will identify increased vascular risk in most of these patients. The absence of a bruit was rarely a false-negative finding, suggesting that these patients can usually be reassured that they do not have hemodynamically important stenosis.

  5. KM3NeT Digital Optical Module electronics

    NASA Astrophysics Data System (ADS)

    Real, Diego

    2016-04-01

    The KM3NeT collaboration is currently building of a neutrino telescope with a volume of several cubic kilometres at the bottom of the Mediterranean Sea. The telescope consists of a matrix of Digital Optical Modules that will detect the Cherenkov light originated by the interaction of the neutrinos in the proximity of the detector. This contribution describes the main components of the read-out electronics of the Digital Optical Module: the Power Board, which delivers all the power supply required by the Digital Optical Molule electronics; the Central Logic Board, the main core of the read-out system, hosting 31 Time to Digital Converters with 1 ns resolution and the White Rabbit protocol embedded in the Central Logic Board Field Programmable Gate Array; the Octopus boards, that transfer the Low Voltage Digital Signals from the PMT bases to the Central Logic Board and finally the PMT bases, in charge of converting the analogue signal produced in the 31 3" PMTs into a Low Voltage Digital Signal.

  6. AVIRIS onboard data handling and control

    NASA Technical Reports Server (NTRS)

    Steinkraus, Ronald E.; Hickok, Roger W.

    1987-01-01

    The timing and flow of detector and ancillary data for the Airborne Visible/Infrared imaging spectrometer (AVIRIS) are controlled within the instrument by its digital electronics assembly. In addition to providing detector and signal chain timing, the digital electronics receives, formats, and rate-buffers digitized science data; collects and formats ancillary (calibration and engineering) data; and merges both into a single tape record. Overall AVIRIS data handling is effected by a combination of dedicated digital electronics to control instrument timing, image data flow, and data rate buffering and a microcomputer programmed to handle real-time control of instrument mechanisms and the coordinated preparation of ancillary data.

  7. A multi-purpose open-source triggering platform for magnetic resonance

    NASA Astrophysics Data System (ADS)

    Ruytenberg, T.; Webb, A. G.; Beenakker, J. W. M.

    2014-10-01

    Many MR scans need to be synchronised with external events such as the cardiac or respiratory cycles. For common physiological functions commercial trigger equipment exists, but for more experimental inputs these are not available. This paper describes the design of a multi-purpose open-source trigger platform for MR systems. The heart of the system is an open-source Arduino Due microcontroller. This microcontroller samples an analogue input and digitally processes these data to determine the trigger. The output of the microcontroller is programmed to mimic a physiological signal which is fed into the electrocardiogram (ECG) or pulse oximeter port of MR scanner. The microcontroller is connected to a Bluetooth dongle that allows wireless monitoring and control outside the scanner room. This device can be programmed to generate a trigger based on various types of input. As one example, this paper describes how it can be used as an acoustic cardiac triggering unit. For this, a plastic stethoscope is connected to a microphone which is used as an input for the system. This test setup was used to acquire retrospectively-triggered cardiac scans in ten volunteers. Analysis showed that this platform produces a reliable trigger (>99% triggers are correct) with a small average 8 ms variation between the exact trigger points.

  8. A multi-purpose open-source triggering platform for magnetic resonance.

    PubMed

    Ruytenberg, T; Webb, A G; Beenakker, J W M

    2014-10-01

    Many MR scans need to be synchronised with external events such as the cardiac or respiratory cycles. For common physiological functions commercial trigger equipment exists, but for more experimental inputs these are not available. This paper describes the design of a multi-purpose open-source trigger platform for MR systems. The heart of the system is an open-source Arduino Due microcontroller. This microcontroller samples an analogue input and digitally processes these data to determine the trigger. The output of the microcontroller is programmed to mimic a physiological signal which is fed into the electrocardiogram (ECG) or pulse oximeter port of MR scanner. The microcontroller is connected to a Bluetooth dongle that allows wireless monitoring and control outside the scanner room. This device can be programmed to generate a trigger based on various types of input. As one example, this paper describes how it can be used as an acoustic cardiac triggering unit. For this, a plastic stethoscope is connected to a microphone which is used as an input for the system. This test setup was used to acquire retrospectively-triggered cardiac scans in ten volunteers. Analysis showed that this platform produces a reliable trigger (>99% triggers are correct) with a small average 8 ms variation between the exact trigger points. Copyright © 2014 Elsevier Inc. All rights reserved.

  9. Telemedicine Networks of EHAS Foundation in Latin America

    PubMed Central

    Prieto-Egido, Ignacio; Simó-Reigadas, Javier; Liñán-Benítez, Leopoldo; García-Giganto, Víctor; Martínez-Fernández, Andrés

    2014-01-01

    Rural areas in developing countries are characterized by lack of resources, low population density, and scarcity of communications infrastructure. These circumstances make it difficult to provide appropriate health-care services. This paper explains research results achieved by Enlace Hispano Americano de Salud – Hispano American Health Link (EHAS) and how they have contributed to improve healthcare in isolated areas of developing countries through the use of information and communication technologies (ICT). As the first step, EHAS always collaborates with public health systems to identify its communication and information needs. Based on the analysis of needs, EHAS does research on appropriate technologies to provide communication in each context and on information systems suited to needs of health personnel. In parallel, EHAS has worked to provide applications that, making use of the communications services installed, could improve the health-care services in these remote areas. In this line, solutions to improve epidemiological surveillance or to provide telemedicine services (like a digital stethoscope or a tele-microscopy system) have been developed. EHAS has also performed several researches trying to ensure the sustainability of their solutions and has summarized them in a Management Framework for Sustainable e-Healthcare Provision. Finally, the effort to spread acquired knowledge has crystallized in a book that details all the technologies and procedures previously mentioned. PMID:25360436

  10. Upgraded Readout Electronics for the ATLAS Liquid Argon Calorimeters at the High Luminosity LHC

    NASA Astrophysics Data System (ADS)

    Andeen, Timothy R.; ATLAS Liquid Argon Calorimeter Group

    2012-12-01

    The ATLAS liquid-argon calorimeters produce a total of 182,486 signals which are digitized and processed by the front-end and back-end electronics at every triggered event. In addition, the front-end electronics sum analog signals to provide coarsely grained energy sums, called trigger towers, to the first-level trigger system, which is optimized for nominal LHC luminosities. However, the pile-up background expected during the high luminosity phases of the LHC will be increased by factors of 3 to 7. An improved spatial granularity of the trigger primitives is therefore proposed in order to improve the identification performance for trigger signatures, like electrons or photons, at high background rejection rates. For the first upgrade phase in 2018, new Liquid Argon Trigger Digitizer Boards are being designed to receive higher granularity signals, digitize them on detector and send them via fast optical links to a new, off-detector digital processing system. The digital processing system applies digital filtering and identifies significant energy depositions. The refined trigger primitives are then transmitted to the first level trigger system to extract improved trigger signatures. The general concept of the upgraded liquid-argon calorimeter readout together with the various electronics components to be developed for such a complex system is presented. The research activities and architectural studies undertaken by the ATLAS Liquid Argon Calorimeter Group are described, particularly details of the on-going design of mixed-signal front-end electronics, of radiation tolerant optical-links, and of the high-speed off-detector digital processing system.

  11. Fault tolerant programmable digital attitude control electronics study

    NASA Technical Reports Server (NTRS)

    Sorensen, A. A.

    1974-01-01

    The attitude control electronics mechanization study to develop a fault tolerant autonomous concept for a three axis system is reported. Programmable digital electronics are compared to general purpose digital computers. The requirements, constraints, and tradeoffs are discussed. It is concluded that: (1) general fault tolerance can be achieved relatively economically, (2) recovery times of less than one second can be obtained, (3) the number of faulty behavior patterns must be limited, and (4) adjoined processes are the best indicators of faulty operation.

  12. Music-of-Light Stethoscope: A Demonstration of the Photoacoustic Effect

    ERIC Educational Resources Information Center

    Nikitichev, D. I.; Xia, W.; Hill, E.; Mosse, C. A.; Perkins, T.; Konyn, K.; Ourselin, S.; Desjardins, A. E.; Vercauteren, T.

    2016-01-01

    In this paper we present a system aimed at demonstrating the photoacoustic (PA) effect for educational purposes. PA imaging is a hybrid imaging modality that requires no contrast agent and has a great potential for spine and brain lesion characterisation, breast cancer and blood flow monitoring notably in the context of fetal surgery. It relies on…

  13. Students Combine Studies with Stethoscopes | Poster

    Cancer.gov

    By Nancy Parrish, Staff Writer Janine Bahsali and Esther Shafer are Middletown High School seniors who go to school in the morning and spend their afternoons taking blood pressure, assisting with physical exams, learning how to draw a blood sample and stitch a wound closed, and generally assisting the staff of Occupational Health Services (OHS), a health care department

  14. Reframing the Field of Gender and Nursing Education

    ERIC Educational Resources Information Center

    Solbraekke, Kari Nyheim; Solvoll, Betty-Ann; Heggen, Kristin M.

    2013-01-01

    The aim of this article is to explore how male students learn to practice nursing and the role of technology in their training process. The study is inspired by Bruno Latour's understanding of social interaction as an interplay between humans and technology. The students' use of the washcloth and the stethoscope, two significant nursing tools, is…

  15. Recent Radiation Damage and Single Event Effect Results for Candidate Spacecraft Electronics

    NASA Technical Reports Server (NTRS)

    OBryan, Martha V.; LaBel, Kenneth A.; Reed, Robert A.; Ladbury, Ray L.; Howard, James W., Jr.; Buchner, Stephen P.; Barth, Janet L.; Kniffen, Scott D.; Seidleck, Christina M.; Marshall, Cheryl J.; hide

    2001-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to proton and heavy-ion induced single-event effects and proton-induced damage. Devices tested include optoelectronics, digital, analog, linear bipolar, hybrid devices, Analog-to-Digital Converters (ADCs), Digital-to-Analog Converters (DACs), and DC-DC converters, among others.

  16. Current Single Event Effects and Radiation Damage Results for Candidate Spacecraft Electronics

    NASA Technical Reports Server (NTRS)

    OBryan, Martha V.; LaBel, Kenneth A.; Reed, Robert A.; Ladbury, Ray L.; Howard, James W., Jr.; Kniffin, Scott D.; Poivey, Christian; Buchner, Stephen P.; Bings, John P.; Titus, Jeff L.

    2002-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to proton and heavy ion induced single event effects, total ionizing dose and proton-induced damage. Devices tested include optoelectronics, digital, analog, linear bipolar, hybrid devices, Analog-to-Digital Converters (ADCs), Digital-to-Analog Converters (DACs), and DC-DC converters, among others.

  17. Analysis and design of digital output interface devices for gas turbine electronic controls

    NASA Technical Reports Server (NTRS)

    Newirth, D. M.; Koenig, E. W.

    1976-01-01

    A trade study was performed on twenty-one digital output interface schemes for gas turbine electronic controls to select the most promising scheme based on criteria of reliability, performance, cost, and sampling requirements. The most promising scheme, a digital effector with optical feedback of the fuel metering valve position, was designed.

  18. 7 CFR 1770.15 - Supplementary accounts required of all borrowers.

    Code of Federal Regulations, 2012 CFR

    2012-01-01

    ... Switching—Circuit. 2212.2 2212.2 Digital Electronic Switching—Packet. 2230.11 Central Office Transmission... Retirement Work in Progress. Current Liabilities 2232.1 2232.1 Circuit Equipment—Electronic. 2232.2 2232.2... Expense—Circuit. 6212.2 6212.2 Digital Electronic Switching Expense—Packet. 6230.11 Radio Systems Expense...

  19. 7 CFR 1770.15 - Supplementary accounts required of all borrowers.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... Switching—Circuit. 2212.2 2212.2 Digital Electronic Switching—Packet. 2230.11 Central Office Transmission... Retirement Work in Progress. Current Liabilities 2232.1 2232.1 Circuit Equipment—Electronic. 2232.2 2232.2... Expense—Circuit. 6212.2 6212.2 Digital Electronic Switching Expense—Packet. 6230.11 Radio Systems Expense...

  20. 7 CFR 1770.15 - Supplementary accounts required of all borrowers.

    Code of Federal Regulations, 2011 CFR

    2011-01-01

    ... Switching—Circuit. 2212.2 2212.2 Digital Electronic Switching—Packet. 2230.11 Central Office Transmission... Retirement Work in Progress. Current Liabilities 2232.1 2232.1 Circuit Equipment—Electronic. 2232.2 2232.2... Expense—Circuit. 6212.2 6212.2 Digital Electronic Switching Expense—Packet. 6230.11 Radio Systems Expense...

  1. Microscale Digital Vacuum Electronic Gates

    NASA Technical Reports Server (NTRS)

    Manohara, Harish (Inventor); Mojarradi, Mohammed M. (Inventor)

    2014-01-01

    Systems and methods in accordance with embodiments of the invention implement microscale digital vacuum electronic gates. In one embodiment, a microscale digital vacuum electronic gate includes: a microscale field emitter that can emit electrons and that is a microscale cathode; and a microscale anode; where the microscale field emitter and the microscale anode are disposed within at least a partial vacuum; where the microscale field emitter and the microscale anode are separated by a gap; and where the potential difference between the microscale field emitter and the microscale anode is controllable such that the flow of electrons between the microscale field emitter and the microscale anode is thereby controllable; where when the microscale anode receives a flow of electrons, a first logic state is defined; and where when the microscale anode does not receive a flow of electrons, a second logic state is defined.

  2. Digital interface of electronic transformers based on embedded system

    NASA Astrophysics Data System (ADS)

    Shang, Qiufeng; Qi, Yincheng

    2008-10-01

    Benefited from digital interface of electronic transformers, information sharing and system integration in substation can be realized. An embedded system-based digital output scheme of electronic transformers is proposed. The digital interface is designed with S3C44B0X 32bit RISC microprocessor as the hardware platform. The μCLinux operation system (OS) is transplanted on ARM7 (S3C44B0X). Applying Ethernet technology as the communication mode in the substation automation system is a new trend. The network interface chip RTL8019AS is adopted. Data transmission is realized through the in-line TCP/IP protocol of uClinux embedded OS. The application result and character analysis show that the design can meet the real-time and reliability requirements of IEC60044-7/8 electronic voltage/current instrument transformer standards.

  3. Propulsion controls

    NASA Technical Reports Server (NTRS)

    Harkney, R. D.

    1980-01-01

    Increased system requirements and functional integration with the aircraft have placed an increased demand on control system capability and reliability. To provide these at an affordable cost and weight and because of the rapid advances in electronic technology, hydromechanical systems are being phased out in favor of digital electronic systems. The transition is expected to be orderly from electronic trimming of hydromechanical controls to full authority digital electronic control. Future propulsion system controls will be highly reliable full authority digital electronic with selected component and circuit redundancy to provide the required safety and reliability. Redundancy may include a complete backup control of a different technology for single engine applications. The propulsion control will be required to communicate rapidly with the various flight and fire control avionics as part of an integrated control concept.

  4. Electronics. Module 3: Digital Logic Application. Instructor's Guide.

    ERIC Educational Resources Information Center

    Carter, Ed; Murphy, Mark

    This guide contains instructor's materials for a 10-unit secondary school course on digital logic application. The units are introduction to digital, logic gates, digital integrated circuits, combination logic, flip-flops, counters and shift registers, encoders and decoders, arithmetic circuits, memory, and analog/digital and digital/analog…

  5. Digital Games for Young Children Ages Three to Six: From Research to Design

    ERIC Educational Resources Information Center

    Lieberman, Debra A.; Fisk, Maria Chesley; Biely, Erica

    2009-01-01

    Young children ages 3 to 6 play a wide range of digital games, which are now available on large screens, handheld screens, electronic learning systems, and electronic toys, and their time spent with games is growing. This article examines effects of digital games and how they could be designed to best serve children's needs. A small body of…

  6. General-Purpose Electronic System Tests Aircraft

    NASA Technical Reports Server (NTRS)

    Glover, Richard D.

    1989-01-01

    Versatile digital equipment supports research, development, and maintenance. Extended aircraft interrogation and display system is general-purpose assembly of digital electronic equipment on ground for testing of digital electronic systems on advanced aircraft. Many advanced features, including multiple 16-bit microprocessors, pipeline data-flow architecture, advanced operating system, and resident software-development tools. Basic collection of software includes program for handling many types of data and for displays in various formats. User easily extends basic software library. Hardware and software interfaces to subsystems provided by user designed for flexibility in configuration to meet user's requirements.

  7. "How Am I Doing?": Many Problems but Few Solutions Related to Feedback Delivery in Undergraduate Psychiatry Education

    ERIC Educational Resources Information Center

    McIlwrick, Joann; Nair, Bina; Montgomery, Gregory

    2006-01-01

    Objective: Giving performance feedback to students in psychiatry requires particular delicacy and skill since a critique of the subjective artistry of the psychiatric interview may be felt more personally than a critique of an objective skill, such as eliciting a reflex or applying a stethoscope to the chest. Thus, one would expect that…

  8. Telemedicine. Final report/project accomplishments summary CRADA number 95-KCP-1014

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    VanDeusen, A.L.

    1997-04-01

    This project was initiated to fill existing voids in the telemedicine equipment market. Currently, when a medical facility adds telemedicine capability to their video conference system, they must purchase expensive and bulky encoders and decoders in order to send information over the available data channel. Even with this expensive equipment, only one data type (stethoscope or ECG) can be sent at a time. In addition, since existing encoders and decoders are not designed specifically for telemedicine, special cables must be built to connect with this equipment. This project resulted in the design and construction of an encoder/decoder system that resolvedmore » these issues. The unit (referred to as the Telecoder) is designed specifically for the telemedicine market. The Telecoder is compact, handles two types of data (stethoscope and ECG) simultaneously, integrates with existing medical equipment, and is less expensive. In addition to the Telecoder module, a prototype was built that adds all the necessary logic and interfaces necessary to integrate the basic encoder design into additional Cardionics products. Although a complete integration into other Cardionics products was not in the scope of this CRADA, all the basic design work has been done to allow Cardionics to complete the work.« less

  9. Listening panel agreement and characteristics of lung sounds digitally recorded from children aged 1–59 months enrolled in the Pneumonia Etiology Research for Child Health (PERCH) case–control study

    PubMed Central

    Park, Daniel E; Watson, Nora L; Buck, W Chris; Bunthi, Charatdao; Devendra, Akash; Ebruke, Bernard E; Elhilali, Mounya; Emmanouilidou, Dimitra; Garcia-Prats, Anthony J; Githinji, Leah; Hossain, Lokman; Madhi, Shabir A; Moore, David P; Mulindwa, Justin; Olson, Dan; Awori, Juliet O; Vandepitte, Warunee P; Verwey, Charl; West, James E; Knoll, Maria D; O'Brien, Katherine L; Feikin, Daniel R; Hammit, Laura L

    2017-01-01

    Introduction Paediatric lung sound recordings can be systematically assessed, but methodological feasibility and validity is unknown, especially from developing countries. We examined the performance of acoustically interpreting recorded paediatric lung sounds and compared sound characteristics between cases and controls. Methods Pneumonia Etiology Research for Child Health staff in six African and Asian sites recorded lung sounds with a digital stethoscope in cases and controls. Cases aged 1–59 months had WHO severe or very severe pneumonia; age-matched community controls did not. A listening panel assigned examination results of normal, crackle, wheeze, crackle and wheeze or uninterpretable, with adjudication of discordant interpretations. Classifications were recategorised into any crackle, any wheeze or abnormal (any crackle or wheeze) and primary listener agreement (first two listeners) was analysed among interpretable examinations using the prevalence-adjusted, bias-adjusted kappa (PABAK). We examined predictors of disagreement with logistic regression and compared case and control lung sounds with descriptive statistics. Results Primary listeners considered 89.5% of 792 case and 92.4% of 301 control recordings interpretable. Among interpretable recordings, listeners agreed on the presence or absence of any abnormality in 74.9% (PABAK 0.50) of cases and 69.8% (PABAK 0.40) of controls, presence/absence of crackles in 70.6% (PABAK 0.41) of cases and 82.4% (PABAK 0.65) of controls and presence/absence of wheeze in 72.6% (PABAK 0.45) of cases and 73.8% (PABAK 0.48) of controls. Controls, tachypnoea, >3 uninterpretable chest positions, crying, upper airway noises and study site predicted listener disagreement. Among all interpretable examinations, 38.0% of cases and 84.9% of controls were normal (p<0.0001); wheezing was the most common sound (49.9%) in cases. Conclusions Listening panel and case–control data suggests our methodology is feasible, likely valid and that small airway inflammation is common in WHO pneumonia. Digital auscultation may be an important future pneumonia diagnostic in developing countries. PMID:28883927

  10. Listening panel agreement and characteristics of lung sounds digitally recorded from children aged 1-59 months enrolled in the Pneumonia Etiology Research for Child Health (PERCH) case-control study.

    PubMed

    McCollum, Eric D; Park, Daniel E; Watson, Nora L; Buck, W Chris; Bunthi, Charatdao; Devendra, Akash; Ebruke, Bernard E; Elhilali, Mounya; Emmanouilidou, Dimitra; Garcia-Prats, Anthony J; Githinji, Leah; Hossain, Lokman; Madhi, Shabir A; Moore, David P; Mulindwa, Justin; Olson, Dan; Awori, Juliet O; Vandepitte, Warunee P; Verwey, Charl; West, James E; Knoll, Maria D; O'Brien, Katherine L; Feikin, Daniel R; Hammit, Laura L

    2017-01-01

    Paediatric lung sound recordings can be systematically assessed, but methodological feasibility and validity is unknown, especially from developing countries. We examined the performance of acoustically interpreting recorded paediatric lung sounds and compared sound characteristics between cases and controls. Pneumonia Etiology Research for Child Health staff in six African and Asian sites recorded lung sounds with a digital stethoscope in cases and controls. Cases aged 1-59 months had WHO severe or very severe pneumonia; age-matched community controls did not. A listening panel assigned examination results of normal, crackle, wheeze, crackle and wheeze or uninterpretable, with adjudication of discordant interpretations. Classifications were recategorised into any crackle, any wheeze or abnormal (any crackle or wheeze) and primary listener agreement (first two listeners) was analysed among interpretable examinations using the prevalence-adjusted, bias-adjusted kappa (PABAK). We examined predictors of disagreement with logistic regression and compared case and control lung sounds with descriptive statistics. Primary listeners considered 89.5% of 792 case and 92.4% of 301 control recordings interpretable. Among interpretable recordings, listeners agreed on the presence or absence of any abnormality in 74.9% (PABAK 0.50) of cases and 69.8% (PABAK 0.40) of controls, presence/absence of crackles in 70.6% (PABAK 0.41) of cases and 82.4% (PABAK 0.65) of controls and presence/absence of wheeze in 72.6% (PABAK 0.45) of cases and 73.8% (PABAK 0.48) of controls. Controls, tachypnoea, >3 uninterpretable chest positions, crying, upper airway noises and study site predicted listener disagreement. Among all interpretable examinations, 38.0% of cases and 84.9% of controls were normal (p<0.0001); wheezing was the most common sound (49.9%) in cases. Listening panel and case-control data suggests our methodology is feasible, likely valid and that small airway inflammation is common in WHO pneumonia. Digital auscultation may be an important future pneumonia diagnostic in developing countries.

  11. Shaping the Values of Youth: Sunday School Books in 19th Century America

    Science.gov Websites

    develop accessible digital/electronic collections, unfortunately, not all are. The MSU Libraries are able to provide remediated, accessible versions of digital/electronic library documents to library users

  12. Flight evaluation of modifications to a digital electronic engine control system in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Burcham, F. W., Jr.; Myers, L. P.; Zeller, J. R.

    1983-01-01

    The third phase of a flight evaluation of a digital electronic engine control system in an F-15 has recently been completed. It was found that digital electronic engine control software logic changes and augmentor hardware improvements resulted in significant improvements in engine operation. For intermediate to maximum power throttle transients, an increase in altitude capability of up to 8000 ft was found, and for idle to maximum transients, an increase of up to 4000 ft was found. A nozzle instability noted in earlier flight testing was investigated on a test engine at NASA Lewis Research Center, a digital electronic engine control software logic change was developed and evaluated, and no instability occurred in the Phase 3 flight evaluation. The backup control airstart modification was evaluated, and gave an improvement of airstart capability by reducing the minimum airspeed for successful airstarts by 50 to 75 knots.

  13. Dual function seal: visualized digital signature for electronic medical record systems.

    PubMed

    Yu, Yao-Chang; Hou, Ting-Wei; Chiang, Tzu-Chiang

    2012-10-01

    Digital signature is an important cryptography technology to be used to provide integrity and non-repudiation in electronic medical record systems (EMRS) and it is required by law. However, digital signatures normally appear in forms unrecognizable to medical staff, this may reduce the trust from medical staff that is used to the handwritten signatures or seals. Therefore, in this paper we propose a dual function seal to extend user trust from a traditional seal to a digital signature. The proposed dual function seal is a prototype that combines the traditional seal and digital seal. With this prototype, medical personnel are not just can put a seal on paper but also generate a visualized digital signature for electronic medical records. Medical Personnel can then look at the visualized digital signature and directly know which medical personnel generated it, just like with a traditional seal. Discrete wavelet transform (DWT) is used as an image processing method to generate a visualized digital signature, and the peak signal to noise ratio (PSNR) is calculated to verify that distortions of all converted images are beyond human recognition, and the results of our converted images are from 70 dB to 80 dB. The signature recoverability is also tested in this proposed paper to ensure that the visualized digital signature is verifiable. A simulated EMRS is implemented to show how the visualized digital signature can be integrity into EMRS.

  14. Multipurpose panel, phase 1, study report. [display utilizing multiplexing and digital techniques

    NASA Technical Reports Server (NTRS)

    Parkin, W.

    1975-01-01

    The feasibility of a multipurpose panel which provides a programmable electronic display for changeable panel nomenclature, multiplexes similar indicator display signals to the signal display, and demultiplexes command signals is examined. Topics discussed include: electronic display technology, miniaturized electronic and memory devices, and data management systems which employ digital address and multiplexing.

  15. Propulsion control experience used in the Highly Integrated Digital Electronic Control (HIDEC) program

    NASA Technical Reports Server (NTRS)

    Myers, L. P.; Burcham, F. W., Jr.

    1984-01-01

    The highly integrated digital electronic control (HIDEC) program will integrate the propulsion and flight control systems on an F-15 airplane at NASA Ames Research Center's Dryden Flight Research Facility. Ames-Dryden has conducted several propulsion control programs that have contributed to the HIDEC program. The digital electronic engine control (DEEC) flight evaluation investigated the performance and operability of the F100 engine equipped with a full-authority digital electronic control system. Investigations of nozzle instability, fault detection and accommodation, and augmentor transient capability provided important information for the HIDEC program. The F100 engine model derivative (EMD) was also flown in the F-15 airplane, and airplane performance was significantly improved. A throttle response problem was found and solved with a software fix to the control logic. For the HIDEC program, the F100 EMD engines equipped with DEEC controls will be integrated with the digital flight control system. The control modes to be implemented are an integrated flightpath management mode and an integrated adaptive engine control system mode. The engine control experience that will be used in the HIDEC program is discussed.

  16. LC21-Hopes and Cautions for the Library of Congress; The NSF National Science, Mathematics, Engineering, and Technology Education Digital Library (NSDL) Program: A Progress Report; A Grammar of Dublin Core; Measuring the Impact of an Electronic Journal Collection on Library Costs: A Framework and Preliminary Observations; Emulation As a Digital Preservation Strategy.

    ERIC Educational Resources Information Center

    O'Donnell, James J.; Zia, Lee L.; Baker, Thomas; Montgomery, Carol Hansen; Granger, Stewart

    2000-01-01

    Includes five articles: (1) discusses Library of Congress efforts to include digital materials; (2) describes the National Science Foundation (NSF) digital library program to improve science, math, engineering, and technology education; (3) explains Dublin Core grammar; (4) measures the impact of electronic journals on library costs; and (5)…

  17. Development strategy and process models for phased automation of design and digital manufacturing electronics

    NASA Astrophysics Data System (ADS)

    Korshunov, G. I.; Petrushevskaya, A. A.; Lipatnikov, V. A.; Smirnova, M. S.

    2018-03-01

    The strategy of quality of electronics insurance is represented as most important. To provide quality, the processes sequence is considered and modeled by Markov chain. The improvement is distinguished by simple database means of design for manufacturing for future step-by-step development. Phased automation of design and digital manufacturing electronics is supposed. The MatLab modelling results showed effectiveness increase. New tools and software should be more effective. The primary digital model is proposed to represent product in the processes sequence from several processes till the whole life circle.

  18. Digital Electronic Engine Control (DEEC) Flight Evaluation in an F-15 Airplane

    NASA Technical Reports Server (NTRS)

    1984-01-01

    Flight evaluation in an F-15 aircraft by digital electronic engine control (DEEC) was investigated. Topics discussed include: system description, F100 engine tests, effects of inlet distortion on static pressure probe, flight tests, digital electronic engine control fault detection and accommodation flight evaluation, flight evaluation of a hydromechanical backup control, augmentor transient capability of an F100 engine, investigation of nozzle instability, real time in flight thrust calculation, and control technology for future aircraft propulsion systems. It is shown that the DEEC system is a powerful and flexible controller for the F100 engine.

  19. Digital diffractive optics: Have diffractive optics entered mainstream industry yet?

    NASA Astrophysics Data System (ADS)

    Kress, Bernard; Hejmadi, Vic

    2010-05-01

    When a new technology is integrated into industry commodity products and consumer electronic devices, and sold worldwide in retail stores, it is usually understood that this technology has then entered the realm of mainstream technology and therefore mainstream industry. Such a leap however does not come cheap, as it has a double edge sword effect: first it becomes democratized and thus massively developed by numerous companies for various applications, but also it becomes a commodity, and thus gets under tremendous pressure to cut down its production and integration costs while not sacrificing to performance. We will show, based on numerous examples extracted from recent industry history, that the field of Diffractive Optics is about to undergo such a major transformation. Such a move has many impacts on all facets of digital diffractive optics technology, from the optical design houses to the micro-optics foundries (for both mastering and volume replication), to the final product integrators or contract manufacturers. The main causes of such a transformation are, as they have been for many other technologies in industry, successive technological bubbles which have carried and lifted up diffractive optics technology within the last decades. These various technological bubbles have been triggered either by real industry needs or by virtual investment hype. Both of these causes will be discussed in the paper. The adjective ""digital"" in "digital diffractive optics" does not refer only, as it is done in digital electronics, to the digital functionality of the element (digital signal processing), but rather to the digital way they are designed (by a digital computer) and fabricated (as wafer level optics using digital masking techniques). However, we can still trace a very strong similarity between the emergence of micro-electronics from analog electronics half a century ago, and the emergence of digital optics from conventional optics today.

  20. Superconductor Digital Electronics: -- Current Status, Future Prospects

    NASA Astrophysics Data System (ADS)

    Mukhanov, Oleg

    2011-03-01

    Two major applications of superconductor electronics: communications and supercomputing will be presented. These areas hold a significant promise of a large impact on electronics state-of-the-art for the defense and commercial markets stemming from the fundamental advantages of superconductivity: simultaneous high speed and low power, lossless interconnect, natural quantization, and high sensitivity. The availability of relatively small cryocoolers lowered the foremost market barrier for cryogenically-cooled superconductor electronic systems. These fundamental advantages enabled a novel Digital-RF architecture - a disruptive technological approach changing wireless communications, radar, and surveillance system architectures dramatically. Practical results were achieved for Digital-RF systems in which wide-band, multi-band radio frequency signals are directly digitized and digital domain is expanded throughout the entire system. Digital-RF systems combine digital and mixed signal integrated circuits based on Rapid Single Flux Quantum (RSFQ) technology, superconductor analog filter circuits, and semiconductor post-processing circuits. The demonstrated cryocooled Digital-RF systems are the world's first and fastest directly digitizing receivers operating with live satellite signals, enabling multi-net data links, and performing signal acquisition from HF to L-band with 30 GHz clock frequencies. In supercomputing, superconductivity leads to the highest energy efficiencies per operation. Superconductor technology based on manipulation and ballistic transfer of magnetic flux quanta provides a superior low-power alternative to CMOS and other charge-transfer based device technologies. The fundamental energy consumption in SFQ circuits defined by flux quanta energy 2 x 10-19 J. Recently, a novel energy-efficient zero-static-power SFQ technology, eSFQ/ERSFQ was invented, which retains all advantages of standard RSFQ circuits: high-speed, dc power, internal memory. The voltage bias regulation, determined by SFQ clock, enables the zero-power at zero-activity regimes, indispensable for sensor and quantum bit readout.

  1. Healthcare Personnel Attire and Devices as Fomites: A Systematic Review.

    PubMed

    Haun, Nicholas; Hooper-Lane, Christopher; Safdar, Nasia

    2016-11-01

    BACKGROUND Transmission of pathogens within the hospital environment remains a hazard for hospitalized patients. Healthcare personnel clothing and devices carried by them may harbor pathogens and contribute to the risk of pathogen transmission. OBJECTIVE To examine bacterial contamination of healthcare personnel attire and commonly used devices. METHODS Systematic review. RESULTS Of 1,175 studies screened, 72 individual studies assessed contamination of a variety of items, including white coats, neckties, stethoscopes, and mobile electronic devices, with varied pathogens including Staphylococcus aureus, including methicillin-resistant S. aureus, gram-negative rods, and enterococci. Contamination rates varied significantly across studies and by device but in general ranged from 0 to 32% for methicillin-resistant S. aureus and gram-negative rods. Enterococcus was a less common contaminant. Few studies explicitly evaluated for the presence of Clostridium difficile. Sampling and microbiologic techniques varied significantly across studies. Four studies evaluated for possible connection between healthcare personnel contaminants and clinical isolates with no unequivocally direct link identified. CONCLUSIONS Further studies to explore the relationship between healthcare personnel attire and devices and clinical infection are needed. Infect Control Hosp Epidemiol 2016;1-7.

  2. Thermal radiation scanning tunnelling microscopy

    NASA Astrophysics Data System (ADS)

    de Wilde, Yannick; Formanek, Florian; Carminati, Rémi; Gralak, Boris; Lemoine, Paul-Arthur; Joulain, Karl; Mulet, Jean-Philippe; Chen, Yong; Greffet, Jean-Jacques

    2006-12-01

    In standard near-field scanning optical microscopy (NSOM), a subwavelength probe acts as an optical `stethoscope' to map the near field produced at the sample surface by external illumination. This technique has been applied using visible, infrared, terahertz and gigahertz radiation to illuminate the sample, providing a resolution well beyond the diffraction limit. NSOM is well suited to study surface waves such as surface plasmons or surface-phonon polaritons. Using an aperture NSOM with visible laser illumination, a near-field interference pattern around a corral structure has been observed, whose features were similar to the scanning tunnelling microscope image of the electronic waves in a quantum corral. Here we describe an infrared NSOM that operates without any external illumination: it is a near-field analogue of a night-vision camera, making use of the thermal infrared evanescent fields emitted by the surface, and behaves as an optical scanning tunnelling microscope. We therefore term this instrument a `thermal radiation scanning tunnelling microscope' (TRSTM). We show the first TRSTM images of thermally excited surface plasmons, and demonstrate spatial coherence effects in near-field thermal emission.

  3. Students Combine Studies with Stethoscopes | Poster

    Cancer.gov

    By Nancy Parrish, Staff Writer Janine Bahsali and Esther Shafer are Middletown High School seniors who go to school in the morning and spend their afternoons taking blood pressure, assisting with physical exams, learning how to draw a blood sample and stitch a wound closed, and generally assisting the staff of Occupational Health Services (OHS), a health care department serving more than 2,000 employees at NCI at Frederick.

  4. US Army Institute of Surgical Research Annual Research Progress Report for Fiscal Year 1987.

    DTIC Science & Technology

    1987-10-01

    oases, respiratory rate, chest roentgenograms), cardiovascular (blood pressure, central venous pressure, cardiac output), and renal (urine output, urine...Monitoring includes the precordial and/or esophageal stethoscope, peripheral pulse, blood pressure, central venous pressure, Swan-Ganz catheter... central venous , peripheral venous , and Swan-Ganz (7F, American Edward Laboratories, Irvine CA) catheters and an esophageal balloon were inserted. After a 2

  5. About egophony.

    PubMed

    Sapira, J D

    1995-09-01

    Egophony is a change in timbre (Ee to A) but not pitch or volume. It is due to a decrease in the amplitude and an increase in the frequency [corrected] of the second formant, produced by solid (including compressed lung) interposed between the resonator and the stethoscope head. This explains certain difficulties in learning this valuable but currently neglected sign as well as in understanding certain physiologic false-positive occurrences.

  6. Wavelet-Based Adaptive Denoising of Phonocardiographic Records

    DTIC Science & Technology

    2001-10-25

    phonocardiography, including the recording of fetal heart sounds on the maternal abdominal surface. Keywords - phonocardiography, wavelets, denoising, signal... fetal heart rate monitoring [2], [7], [8]. Unfortunately, heart sound records are very often disturbed by various factors, which can prohibit their...recorded the acoustic signals. The first microphone was inserted into the focus of a stethoscope and it recorded the acoustic signals of the heart ( heart

  7. Instructional Methods for Neuroscience in Nurse Anesthesia Graduate Programs: A Survey of Educational Programs

    DTIC Science & Technology

    1999-10-01

    Sciences A. Anatomy, physiology and pathophysiology 1. Cardiovascular a. Arrhythmias b. Ischemic heart disease/angina c. Myocardial infarction d...Hypertension e. Congestive Heart Failure f. Shock Instructional Methods 66 g. Valvular Heart disease h. Cardiomyopathy i. Peripheral vascular disease j...Pulmonary artery pressure monitoring Instructional Methods 71 3. Precordial/esophageal stethoscope /Doppler 4. Respiratory monitoring a. Apnea monitor b

  8. An open real-time tele-stethoscopy system.

    PubMed

    Foche-Perez, Ignacio; Ramirez-Payba, Rodolfo; Hirigoyen-Emparanza, German; Balducci-Gonzalez, Fernando; Simo-Reigadas, Francisco-Javier; Seoane-Pascual, Joaquin; Corral-Peñafiel, Jaime; Martinez-Fernandez, Andres

    2012-08-23

    Acute respiratory infections are the leading cause of childhood mortality. The lack of physicians in rural areas of developing countries makes difficult their correct diagnosis and treatment. The staff of rural health facilities (health-care technicians) may not be qualified to distinguish respiratory diseases by auscultation. For this reason, the goal of this project is the development of a tele-stethoscopy system that allows a physician to receive real-time cardio-respiratory sounds from a remote auscultation, as well as video images showing where the technician is placing the stethoscope on the patient's body. A real-time wireless stethoscopy system was designed. The initial requirements were: 1) The system must send audio and video synchronously over IP networks, not requiring an Internet connection; 2) It must preserve the quality of cardiorespiratory sounds, allowing to adapt the binaural pieces and the chestpiece of standard stethoscopes, and; 3) Cardiorespiratory sounds should be recordable at both sides of the communication. In order to verify the diagnostic capacity of the system, a clinical validation with eight specialists has been designed. In a preliminary test, twelve patients have been auscultated by all the physicians using the tele-stethoscopy system, versus a local auscultation using traditional stethoscope. The system must allow listen the cardiac (systolic and diastolic murmurs, gallop sound, arrhythmias) and respiratory (rhonchi, rales and crepitations, wheeze, diminished and bronchial breath sounds, pleural friction rub) sounds. The design, development and initial validation of the real-time wireless tele-stethoscopy system are described in detail. The system was conceived from scratch as open-source, low-cost and designed in such a way that many universities and small local companies in developing countries may manufacture it. Only free open-source software has been used in order to minimize manufacturing costs and look for alliances to support its improvement and adaptation. The microcontroller firmware code, the computer software code and the PCB schematics are available for free download in a subversion repository hosted in SourceForge. It has been shown that real-time tele-stethoscopy, together with a videoconference system that allows a remote specialist to oversee the auscultation, may be a very helpful tool in rural areas of developing countries.

  9. Digital Audio Radio Broadcast Systems Laboratory Testing Nearly Complete

    NASA Technical Reports Server (NTRS)

    2005-01-01

    Radio history continues to be made at the NASA Lewis Research Center with the completion of phase one of the digital audio radio (DAR) testing conducted by the Consumer Electronics Group of the Electronic Industries Association. This satellite, satellite/terrestrial, and terrestrial digital technology will open up new audio broadcasting opportunities both domestically and worldwide. It will significantly improve the current quality of amplitude-modulated/frequency-modulated (AM/FM) radio with a new digitally modulated radio signal and will introduce true compact-disc-quality (CD-quality) sound for the first time. Lewis is hosting the laboratory testing of seven proposed digital audio radio systems and modes. Two of the proposed systems operate in two modes each, making a total of nine systems being tested. The nine systems are divided into the following types of transmission: in-band on-channel (IBOC), in-band adjacent-channel (IBAC), and new bands. The laboratory testing was conducted by the Consumer Electronics Group of the Electronic Industries Association. Subjective assessments of the audio recordings for each of the nine systems was conducted by the Communications Research Center in Ottawa, Canada, under contract to the Electronic Industries Association. The Communications Research Center has the only CCIR-qualified (Consultative Committee for International Radio) audio testing facility in North America. The main goals of the U.S. testing process are to (1) provide technical data to the Federal Communication Commission (FCC) so that it can establish a standard for digital audio receivers and transmitters and (2) provide the receiver and transmitter industries with the proper standards upon which to build their equipment. In addition, the data will be forwarded to the International Telecommunications Union to help in the establishment of international standards for digital audio receivers and transmitters, thus allowing U.S. manufacturers to compete in the world market.

  10. ELECTRONIC DIGITAL COMPUTER

    DOEpatents

    Stone, J.J. Jr.; Bettis, E.S.; Mann, E.R.

    1957-10-01

    The electronic digital computer is designed to solve systems involving a plurality of simultaneous linear equations. The computer can solve a system which converges rather rapidly when using Von Seidel's method of approximation and performs the summations required for solving for the unknown terms by a method of successive approximations.

  11. Electronic simulation of a barometric pressure sensor for the meteorological monitor assembly

    NASA Technical Reports Server (NTRS)

    Guiar, C. N.; Duff, L. W.

    1982-01-01

    An analysis of the electronic simulation of barometric pressure used to self-test the counter electronics of the digital barometer is presented. The barometer is part of the Meteorological Monitor Assembly that supports navigation in deep space communication. The theory of operation of the digital barometer, the design details, and the verification procedure used with the barometric pressure simulator are presented.

  12. Digital Economy and Management in Spain.

    ERIC Educational Resources Information Center

    del Aguila, Ana R.; Padilla, Antonio; Serarols, Christian; Veciana, Jose M.

    2003-01-01

    Explains the digital economy and its impact on the firm. Highlights include subsectors of the digital economy, including infrastructure; analysis of the digital economy in Spain; analysis of the ICT (information and communication technology) sector in Spain; and electronic commerce through the Internet. (LRW)

  13. Optically-synchronized encoder and multiplexer scheme for interleaved photonics analog-to-digital conversion

    NASA Astrophysics Data System (ADS)

    Villa, Carlos; Kumavor, Patrick; Donkor, Eric

    2008-04-01

    Photonics Analog-to-Digital Converters (ADCs) utilize a train of optical pulses to sample an electrical input waveform applied to an electrooptic modulator or a reverse biased photodiode. In the former, the resulting train of amplitude-modulated optical pulses is detected (converter to electrical) and quantized using a conversional electronics ADC- as at present there are no practical, cost-effective optical quantizers available with performance that rival electronic quantizers. In the latter, the electrical samples are directly quantized by the electronics ADC. In both cases however, the sampling rate is limited by the speed with which the electronics ADC can quantize the electrical samples. One way to increase the sampling rate by a factor N is by using the time-interleaved technique which consists of a parallel array of N electrical ADC converters, which have the same sampling rate but different sampling phase. Each operating at a quantization rate of fs/N where fs is the aggregated sampling rate. In a system with no real-time operation, the N channels digital outputs are stored in memory, and then aggregated (multiplexed) to obtain the digital representation of the analog input waveform. Alternatively, for real-time operation systems the reduction of storing time in the multiplexing process is desired to improve the time response of the ADC. The complete elimination of memories come expenses of concurrent timing and synchronization in the aggregation of the digital signal that became critical for a good digital representation of the analog signal waveform. In this paper we propose and demonstrate a novel optically synchronized encoder and multiplexer scheme for interleaved photonics ADCs that utilize the N optical signals used to sample different phases of an analog input signal to synchronize the multiplexing of the resulting N digital output channels in a single digital output port. As a proof of concept, four 320 Megasamples/sec 12-bit of resolution digital signals were multiplexed to form an aggregated 1.28 Gigasamples/sec single digital output signal.

  14. Detection of bronchial breathing caused by pneumonia.

    PubMed

    Gross, V; Fachinger, P; Penzel, Th; Koehler, U; von Wichert, P; Vogelmeier, C

    2002-06-01

    The classic auscultation with stethoscope is the established clinical method for the detection of lung diseases. The interpretation of the sounds depends on the experience of the investigating physician. Therefore, a new computer-based method has been developed to classify breath sounds from digital lung sound recordings. Lung sounds of 11 patients with one-sided pneumonia and bronchial breathing were recorded on both the pneumonia side and on contralateral healthy side simultaneously using two microphones. The spectral power for the 300-600 Hz frequency band was computed for four respiratory cycles and normalized. For each breath, the ratio R between the time-segments (duration = 0.1 s) with the highest inspiratory and highest expiratory flow was calculated and averaged. We found significant differences in R between the pneumonia side (R = 1.4 +/- 1.3) and the healthy side (R = 0.5 +/- 0.5; p = 0.003 Wilcoxon-test) of lung. In 218 healthy volunteers we found R = 0.3 +/- 0.2 as a reference-value. The differences of ratio R (delta R) between the pneumonia side and the healthy side (delta R = 1.0 +/- 0.9) were significantly higher compared to follow-up studies after recovery (delta R = 0.0 +/- 0.1, p = 0.005 Wilcoxon-test). The computer based detection of bronchial breathing can be considered useful as part of a quantitative monitoring of patients at risk to develop pneumonia.

  15. Uncovering Information Hidden in Web Archives: Glimpse at Web Analysis Building on Data Warehouses; Towards Continuous Web Archiving: First Results and an Agenda for the Future; The Open Video Digital Library; After Migration to an Electronic Journal Collection: Impact on Faculty and Doctoral Students; Who Is Reading On-Line Education Journals? Why? And What Are They Reading?; Report on eLibrary@UBC4: Research, Collaboration and the Digital Library - Visions for 2010.

    ERIC Educational Resources Information Center

    Rauber, Andreas; Bruckner, Robert M.; Aschenbrenner, Andreas; Witvoet, Oliver; Kaiser, Max; Masanes, Julien; Marchionini, Gary; Geisler, Gary; King, Donald W.; Montgomery, Carol Hansen; Rudner, Lawrence M.; Gellmann, Jennifer S.; Miller-Whitehead, Marie; Iverson, Lee

    2002-01-01

    These six articles discuss Web archives and Web analysis building on data warehouses; international efforts at continuous Web archiving; the Open Video Digital Library; electronic journal collections in academic libraries; online education journals; and an electronic library symposium at the University of British Columbia. (LRW)

  16. 47 CFR 36.125 - Local switching equipment-Category 3.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... electronic analog or digital remote line locations. Equipment used for the identification, recording and... which has a common intermediate distributing frame, market group or other separately identifiable... composed of an electronic analog or digital host office and all of its remote locations. A host/remote...

  17. 21 CFR 1305.03 - Distributions requiring a Form 222 or a digitally signed electronic order.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... Distributions requiring a Form 222 or a digitally signed electronic order. Either a DEA Form 222 or its... laboratory or its agent approved by DEA. (d) Delivery from a central fill pharmacy, as defined in § 1300.01(b...

  18. 21 CFR 1305.03 - Distributions requiring a Form 222 or a digitally signed electronic order.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... Distributions requiring a Form 222 or a digitally signed electronic order. Either a DEA Form 222 or its... laboratory or its agent approved by DEA. (d) Delivery from a central fill pharmacy, as defined in § 1300.01(b...

  19. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merchant, Bion J.

    The Seismo-Hydroacoustic Data Acquisition System (SHDAS) is undergoing evaluation in preparation for its engineering, development, and deployment by the U.S Navy as an ocean bottom seismic monitoring system. At the current stage of development, the production digitizers are being evaluated to confirm their performance prior to packaging and assembly for deployment. The testing of the digitizers is being conducted at Delta Group Electronics, the digitizer fabricator, in San Diego, California, performed by Sandia National Laboratories with the assistance of Leidos and Delta Group Electronics.

  20. Designed cell consortia as fragrance-programmable analog-to-digital converters.

    PubMed

    Müller, Marius; Ausländer, Simon; Spinnler, Andrea; Ausländer, David; Sikorski, Julian; Folcher, Marc; Fussenegger, Martin

    2017-03-01

    Synthetic biology advances the rational engineering of mammalian cells to achieve cell-based therapy goals. Synthetic gene networks have nearly reached the complexity of digital electronic circuits and enable single cells to perform programmable arithmetic calculations or to provide dynamic remote control of transgenes through electromagnetic waves. We designed a synthetic multilayered gaseous-fragrance-programmable analog-to-digital converter (ADC) allowing for remote control of digital gene expression with 2-bit AND-, OR- and NOR-gate logic in synchronized cell consortia. The ADC consists of multiple sampling-and-quantization modules sensing analog gaseous fragrance inputs; a gas-to-liquid transducer converting fragrance intensity into diffusible cell-to-cell signaling compounds; a digitization unit with a genetic amplifier circuit to improve the signal-to-noise ratio; and recombinase-based digital expression switches enabling 2-bit processing of logic gates. Synthetic ADCs that can remotely control cellular activities with digital precision may enable the development of novel biosensors and may provide bioelectronic interfaces synchronizing analog metabolic pathways with digital electronics.

  1. Software Defined Radio (SDR) and Direct Digital Synthesizer (DDS) for NMR/MRI instruments at low-field.

    PubMed

    Asfour, Aktham; Raoof, Kosai; Yonnet, Jean-Paul

    2013-11-27

    A proof-of-concept of the use of a fully digital radiofrequency (RF) electronics for the design of dedicated Nuclear Magnetic Resonance (NMR) systems at low-field (0.1 T) is presented. This digital electronics is based on the use of three key elements: a Direct Digital Synthesizer (DDS) for pulse generation, a Software Defined Radio (SDR) for a digital receiving of NMR signals and a Digital Signal Processor (DSP) for system control and for the generation of the gradient signals (pulse programmer). The SDR includes a direct analog-to-digital conversion and a Digital Down Conversion (digital quadrature demodulation, decimation filtering, processing gain…). The various aspects of the concept and of the realization are addressed with some details. These include both hardware design and software considerations. One of the underlying ideas is to enable such NMR systems to "enjoy" from existing advanced technology that have been realized in other research areas, especially in telecommunication domain. Another goal is to make these systems easy to build and replicate so as to help research groups in realizing dedicated NMR desktops for a large palette of new applications. We also would like to give readers an idea of the current trends in this field. The performances of the developed electronics are discussed throughout the paper. First FID (Free Induction Decay) signals are also presented. Some development perspectives of our work in the area of low-field NMR/MRI will be finally addressed.

  2. Social Work in a Digital Age: Ethical and Risk Management Challenges

    ERIC Educational Resources Information Center

    Reamer, Frederic G.

    2013-01-01

    Digital, online, and other electronic technology has transformed the nature of social work practice. Contemporary social workers can provide services to clients by using online counseling, telephone counseling, video counseling, cybertherapy (avatar therapy), self-guided Web-based interventions, electronic social networks, e-mail, and text…

  3. The Acquisition and Management of Electronic Resources: Can Use Justify Cost?

    ERIC Educational Resources Information Center

    Koehn, Shona L.; Hawamdeh, Suliman

    2010-01-01

    As library collections increasingly become digital, libraries are faced with many challenges regarding the acquisition and management of electronic resources. Some of these challenges include copyright and fair use, the first-sale doctrine, licensing versus ownership, digital preservation, long-term archiving, and, most important, the issue of…

  4. The Art of Electronics

    NASA Astrophysics Data System (ADS)

    Horowitz, Paul; Hill, Winfield

    2015-04-01

    1. Foundations; 2. Bipolar transistors; 3. Field effect transistors; 4. Operational amplifiers; 5. Precision circuits; 6. Filters; 7. Oscillators and timers; 8. Low noise techniques and transimpedance; 9. Power regulation; 10. Digital electronics; 11. Programmable logic devices; 12. Logical interfacing; 13. Digital meets analog; 14. Computers, controllers, and data links; 15. Microcontrollers.

  5. 76 FR 25706 - Notice of Receipt of Complaint; Solicitation of Comments Relating to the Public Interest

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-05-05

    ... Certain Electronic Devices Having a Digital Television Receiver and Components Thereof, DN 2801; the... importation of certain electronic devices having a digital television receiver and components thereof. The... health and welfare in the United States, competitive conditions in the United States economy, the...

  6. 76 FR 12994 - In the Matter of Certain Digital Televisions and Components Thereof, and Certain Electronic...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-09

    ... INTERNATIONAL TRADE COMMISSION [Inv. No. 337-TA-764] In the Matter of Certain Digital Televisions and Components Thereof, and Certain Electronic Devices Having a Blu-Ray Disc Player and Components Thereof; Notice of Investigation AGENCY: U.S. International Trade Commission. ACTION: Institution of...

  7. Using PBL to Deliver Course in Digital Electronics

    ERIC Educational Resources Information Center

    Mantri, Archana; Dutt, Sunil; Gupta, J. P; Chitkara, Madhu

    2009-01-01

    Problem Based Learning (PBL) has proven to be a highly successful pedagogical model in many educational fields, although it is comparatively uncommon in technical education. It goes beyond the typical teaching methodology by promoting student interaction. This paper presents a PBL trial applied to an undergraduate Digital Electronics course in the…

  8. 36 CFR 1235.44 - What general transfer requirements apply to electronic records?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... Services Division (NWCS) for digital photographs, 8601 Adelphi Road, College Park, MD 20740, phone number..., Electronic/Special Media Records Services Division (NWME), 8601 Adelphi Road, College Park, MD 20740, phone number (301) 837-3420. (c) When transferring digital photographs and their accompanying metatdata, the...

  9. 36 CFR 1235.44 - What general transfer requirements apply to electronic records?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... Services Division (NWCS) for digital photographs, 8601 Adelphi Road, College Park, MD 20740, phone number..., Electronic/Special Media Records Services Division (NWME), 8601 Adelphi Road, College Park, MD 20740, phone number (301) 837-3420. (c) When transferring digital photographs and their accompanying metatdata, the...

  10. Industrial Electronics II for ICT. Student's Manual.

    ERIC Educational Resources Information Center

    Snider, Bob

    This student manual contains the following six units for classroom and laboratory experiences in high school industrial electronics: (1) introduction and review of DC and AC circuits; (2) semiconductors; (3) integrated circuits; (4) digital basics; (5) complex digital circuits; and (6) computer circuits. The units include unit objectives, specific…

  11. An Evaluation of the Ability of Navy Hospital Corpsmen to Collect Chest Pain Data from Patients

    DTIC Science & Technology

    1984-01-11

    PREVIOUS CARDIO-RESPIRATOFJY ILLNESS: (significant illenss either cardiovascular or respiratory ) YES (64) NO (65) PREVIOUS MAJOR SURGERY...clavicle to chin - elevated) otherwise circle normal) NORMAL (97) RAISED (98) RESPIRATORY MOVEMENT: (abnormal = the difference between...ABNORMAL (100) HEART SOUNDS: (with a stethoscope listen to the 1st and 2nd heart sounds; normal - lub-dub, lub-dub; abnormal " everything else

  12. The Accutension Stetho, an automated auscultatory device to validate automated sphygmomanometer readings in individual patients.

    PubMed

    Alpert, Bruce S

    2018-04-06

    The aim of this report is to describe a new device that can validate, by automated auscultation, individual blood pressure (BP) readings taken by automated sphygmomanometers.The Accutension Stetho utilizes a smartphone application in conjunction with a specially designed stethoscope that interfaces directly into the smartphone via the earphone jack. The Korotkoff sounds are recorded by the application and are analyzed by the operator on the screen of the smartphone simultaneously with the images from the sphygmomanometer screen during BP estimation. Current auscultatory validation standards require at least 85 subjects and strict statistical criteria for passage. A device that passes can make no guarantee of accuracy on individual patients. The Accutension Stetho is an inexpensive smartphone/stethoscope kit combination that estimates precise BP values by auscultation to confirm the accuracy of an automated sphygmomanometer's readings on individual patients. This should be of great value for both professional and, in certain circumstances, self-measurement BP. Patients will avoid both unnecessary treatment and errors of underestimation of BP, in which the patient requires therapy. The Stetho's software has been validated in an independent ANSI/AAMI/ISO standard study. The Stetho has been shown to perform without difficulty in multiple deflation-based devices by many manufacturers.

  13. Bedside ultrasonography (US), Echoscopy and US point of care as a new kind of stethoscope for Internal Medicine Departments: the training program of the Italian Internal Medicine Society (SIMI).

    PubMed

    Arienti, Vincenzo; Di Giulio, Rosella; Cogliati, Chiara; Accogli, Esterita; Aluigi, Leonardo; Corazza, Gino Roberto

    2014-10-01

    In recent years, thanks to the development of miniaturized ultrasound devices, comparable to personal computers, tablets and even to smart phones, we have seen an increasing use of bedside ultrasound in internal medicine departments as a novel kind of ultrasound stethoscope. The clinical ultrasound-assisted approach has proved to be particularly useful in assessing patients with nodules of the neck, dyspnoea, abdominal pain, and with limb edema. In several cases, it has allowed a simple, rapid and precise diagnosis. Since 2005, the Italian Society of Internal Medicine and its Ultrasound Study Group has been holding a Summer School and training courses in ultrasound for residents in internal medicine. A national network of schools in bedside ultrasound was then organized for internal medicine specialists who want to learn this technique. Because bedside ultrasound is a user-dependent diagnostic method, it is important to define the limits and advantages of different new ultrasound devices, to classify them (i.e. Echoscopy and Point of Care Ultrasound), to establish appropriate different levels of competence and to ensure their specific training. In this review, we describe the point of view of the Italian Internal Medicine Society on these topics.

  14. The Generation and Propagation of Arterial Murmurs from a Stenosed Artery: A Computational Study

    NASA Astrophysics Data System (ADS)

    Zhu, Chi; Seo, Jung-Hee; Bakhshaee, Hani; Mittal, Rajat

    2015-11-01

    Cardiac auscultation - the procedure of diagnosing cardiovascular conditions using the stethoscope - has been used effectively for over a hundred years but still, the flow mechanism(s) responsible for the generation of these murmurs, as well as the effect of intervening tissue on the propagation of these murmurs, is not well understood. In this study, a one-way coupled, hybrid approach is used to investigate the propagation of murmurs generated from the flow in a stenosed artery. Specifically, the flow in the modeled artery is solved by an incompressible Navier-Stokes solver with the immersed-boundary method. The structural wave propagation in the tissue is resolved by a high-order, linear viscoelastic wave solver, and a mathematical decomposition is applied to separate the compressional and shear component of the acoustic wave propagating through the tissue. The simulations suggest, somewhat counterintuitively, that the shear wave contributes a significant component to the signal picked up by a stethoscope, and that this component carries much of the information that characterizes the source of the murmur. The implications of this for cardiac auscultation and further modeling of hemoacoustics are discussed. The effect of the stenosis severity and the flow pulsatility will also be investigated. The authors would like to acknowledge the SCH for funding this project.

  15. Hand Washing Practices Among Emergency Medical Services Providers.

    PubMed

    Bucher, Joshua; Donovan, Colleen; Ohman-Strickland, Pamela; McCoy, Jonathan

    2015-09-01

    Hand hygiene is an important component of infection control efforts. Our primary and secondary goals were to determine the reported rates of hand washing and stethoscope cleaning in emergency medical services (EMS) workers, respectively. We designed a survey about hand hygiene practices. The survey was distributed to various national EMS organizations through e-mail. Descriptive statistics were calculated for survey items (responses on a Likert scale) and subpopulations of survey respondents to identify relationships between variables. We used analysis of variance to test differences in means between the subgroups. There were 1,494 responses. Overall, reported hand hygiene practices were poor among pre-hospital providers in all clinical situations. Women reported that they washed their hands more frequently than men overall, although the differences were unlikely to be clinically significant. Hygiene after invasive procedures was reported to be poor. The presence of available hand sanitizer in the ambulance did not improve reported hygiene rates but improved reported rates of cleaning the stethoscope (absolute difference 0.4, p=0.0003). Providers who brought their own sanitizer were more likely to clean their hands. Reported hand hygiene is poor amongst pre-hospital providers. There is a need for future intervention to improve reported performance in pre-hospital provider hand washing.

  16. The prevalence and character of crackles (rales) in young women without significant lung disease.

    PubMed

    Workum, P; Holford, S K; Delbono, E A; Murphy, R L

    1982-11-01

    Although some investigators have reported that crackles are present only in persons with lung disease, others say they also occur in normal persons. In order to clarify this difference of opinion, we determined the prevalence of crackles in 56 women without significant lung disease. The subjects ranged from 19 to 33 yr of age (mean, 21.3). They all had a FVC greater than 80% predicted and a FEV1/FVC ratio greater than 75%. None had a history of acute or chronic lung disease. During slow inspirations from residual volume, midinspiratory fine crackles were heard at the anterior bases in 35 of 56 subjects by a physician using an acoustic stethoscope, whereas a bioengineer using an 800 Hertz high pass filtered stethoscope heard crackles in 53 subjects. Crackles during tidal breathing were heard in 2 subjects. It is postulated that the crackles noted after expiration to residual volume are nonpathologic, and occur when basilar airways, which close at the end of a forced expiration, suddenly open during inspiration. Examination of the quality, timing, and anatomic distribution of the crackles in apparently normal subjects suggests that they can often be distinguished from those resulting from diseases such as bronchitis, interstitial fibrosis, and congestive heart failure.

  17. [Respiratory sounds].

    PubMed

    Marquet, P

    1995-01-01

    After having invented the stethoscope, Laennec published his treatise on auscultation in 1819, describing the acoustic events generated by ventilation and linking them with anatomopathological findings. The weak points of his semiology lay in its subjective and interpretative character, expressed by an imprecise and picturesque nomenclature. Technical studies of breath sounds began in the middle of the twentieth century, and this enabled the American Thoracic Society to elaborate a new classification of adventitious noises based on a few physical characteristics. This terminology replaced that of Laennec or his translators (except in France). The waveforms of the different normal and adventitious noises have been well described. However, only the study of the time evolution of their tone (frequency-amplitude-time relationship) will enable a complete analysis of these phenomena. This approach has been undertaken by a few teams but much remains to be done, in particular in relation to discontinuous noises (crackles). Technology development raises hope for the design, in near future, of automatic processes for respiratory noise detection and classification. Systematic research into the production mechanisms and sites of these noises has progressed equally. It should, in time, reinforce their semiological value and give to auscultation, either instrumental or using the stethoscope or instrumentally, an increased diagnostic power and the status of respiratory function test.

  18. Hand Washing Practices Among Emergency Medical Services Providers

    PubMed Central

    Bucher, Joshua; Donovan, Colleen; Ohman-Strickland, Pamela; McCoy, Jonathan

    2015-01-01

    Introduction Hand hygiene is an important component of infection control efforts. Our primary and secondary goals were to determine the reported rates of hand washing and stethoscope cleaning in emergency medical services (EMS) workers, respectively. Methods We designed a survey about hand hygiene practices. The survey was distributed to various national EMS organizations through e-mail. Descriptive statistics were calculated for survey items (responses on a Likert scale) and subpopulations of survey respondents to identify relationships between variables. We used analysis of variance to test differences in means between the subgroups. Results There were 1,494 responses. Overall, reported hand hygiene practices were poor among pre-hospital providers in all clinical situations. Women reported that they washed their hands more frequently than men overall, although the differences were unlikely to be clinically significant. Hygiene after invasive procedures was reported to be poor. The presence of available hand sanitizer in the ambulance did not improve reported hygiene rates but improved reported rates of cleaning the stethoscope (absolute difference 0.4, p=0.0003). Providers who brought their own sanitizer were more likely to clean their hands. Conclusion Reported hand hygiene is poor amongst pre-hospital providers. There is a need for future intervention to improve reported performance in pre-hospital provider hand washing. PMID:26587098

  19. General-purpose readout electronics for white neutron source at China Spallation Neutron Source

    NASA Astrophysics Data System (ADS)

    Wang, Q.; Cao, P.; Qi, X.; Yu, T.; Ji, X.; Xie, L.; An, Q.

    2018-01-01

    The under-construction White Neutron Source (WNS) at China Spallation Neutron Source is a facility for accurate measurements of neutron-induced cross section. Seven spectrometers are planned at WNS. As the physical objectives of each spectrometer are different, the requirements for readout electronics are not the same. In order to simplify the development of the readout electronics, this paper presents a general method for detector signal readout. This method has advantages of expansibility and flexibility, which makes it adaptable to most detectors at WNS. In the WNS general-purpose readout electronics, signals from any kinds of detectors are conditioned by a dedicated signal conditioning module corresponding to this detector, and then digitized by a common waveform digitizer with high speed and high precision (1 GSPS at 12-bit) to obtain the full waveform data. The waveform digitizer uses a field programmable gate array chip to process the data stream and trigger information in real time. PXI Express platform is used to support the functionalities of data readout, clock distribution, and trigger information exchange between digitizers and trigger modules. Test results show that the performance of the WNS general-purpose readout electronics can meet the requirements of the WNS spectrometers.

  20. European roadmap on superconductive electronics - status and perspectives

    NASA Astrophysics Data System (ADS)

    Anders, S.; Blamire, M. G.; Buchholz, F.-Im.; Crété, D.-G.; Cristiano, R.; Febvre, P.; Fritzsch, L.; Herr, A.; Il'ichev, E.; Kohlmann, J.; Kunert, J.; Meyer, H.-G.; Niemeyer, J.; Ortlepp, T.; Rogalla, H.; Schurig, T.; Siegel, M.; Stolz, R.; Tarte, E.; ter Brake, H. J. M.; Toepfer, H.; Villegier, J.-C.; Zagoskin, A. M.; Zorin, A. B.

    2010-12-01

    Executive SummaryFor four decades semiconductor electronics has followed Moore’s law: with each generation of integration the circuit features became smaller, more complex and faster. This development is now reaching a wall so that smaller is no longer any faster. The clock rate has saturated at about 3-5 GHz and the parallel processor approach will soon reach its limit. The prime reason for the limitation the semiconductor electronics experiences is not the switching speed of the individual transistor, but its power dissipation and thus heat. Digital superconductive electronics is a circuit- and device-technology that is inherently faster at much less power dissipation than semiconductor electronics. It makes use of superconductors and Josephson junctions as circuit elements, which can provide extremely fast digital devices in a frequency range - dependent on the material - of hundreds of GHz: for example a flip-flop has been demonstrated that operated at 750 GHz. This digital technique is scalable and follows similar design rules as semiconductor devices. Its very low power dissipation of only 0.1 μW per gate at 100 GHz opens the possibility of three-dimensional integration. Circuits like microprocessors and analogue-to-digital converters for commercial and military applications have been demonstrated. In contrast to semiconductor circuits, the operation of superconducting circuits is based on naturally standardized digital pulses the area of which is exactly the flux quantum Φ0. The flux quantum is also the natural quantization unit for digital-to-analogue and analogue-to-digital converters. The latter application is so precise, that it is being used as voltage standard and that the physical unit ‘Volt’ is defined by means of this standard. Apart from its outstanding features for digital electronics, superconductive electronics provides also the most sensitive sensor for magnetic fields: the Superconducting Quantum Interference Device (SQUID). Amongst many other applications SQUIDs are used as sensors for magnetic heart and brain signals in medical applications, as sensor for geological surveying and food-processing and for non-destructive testing. As amplifiers of electrical signals, SQUIDs can nearly reach the theoretical limit given by Quantum Mechanics. A further important field of application is the detection of very weak signals by ‘transition-edge’ bolometers, superconducting nanowire single-photon detectors, and superconductive tunnel junctions. Their application as radiation detectors in a wide frequency range, from microwaves to X-rays is now standard. The very low losses of superconductors have led to commercial microwave filter designs that are now widely used in the USA in base stations for cellular phones and in military communication applications. The number of demonstrated applications is continuously increasing and there is no area in professional electronics, in which superconductive electronics cannot be applied and surpasses the performance of classical devices. Superconductive electronics has to be cooled to very low temperatures. Whereas this was a bottleneck in the past, cooling techniques have made a huge step forward in recent years: very compact systems with high reliability and a wide range of cooling power are available commercially, from microcoolers of match-box size with milli-Watt cooling power to high-reliability coolers of many Watts of cooling power for satellite applications. Superconductive electronics will not replace semiconductor electronics and similar room-temperature techniques in standard applications, but for those applications which require very high speed, low-power consumption, extreme sensitivity or extremely high precision, superconductive electronics is superior to all other available techniques. To strengthen the European competitiveness in superconductor electronics research projects have to be set-up in the following field: Ultra-sensitive sensing and imaging. Quantum measurement instrumentation. Advanced analogue-to-digital converters. Superconductive electronics technology.

  1. Radiation Damage and Single Event Effect Results for Candidate Spacecraft Electronics

    NASA Technical Reports Server (NTRS)

    OBryan, Martha V.; LaBel, Kenneth A.; Reed, Robert A.; Howard, James W., Jr.; Ladbury, Ray L.; Barth, Janet L.; Kniffin, Scott D.; Seidleck, Christina M.; Marshall, Paul W.; Marshall, Cheryl J.; hide

    2000-01-01

    We present data on the vulnerability of a variety of candidate spacecraft electronics to proton and heavy-ion induced single-event effects and proton-induced damage. We also present data on the susceptibility of parts to functional degradation resulting from total ionizing dose at low dose rates (0.003-0.33 Rads(Si)/s). Devices tested include optoelectronics, digital, analog, linear bipolar, hybrid devices, Analog to Digital Converters (ADCs), Digital to Analog Converters (DACs), and DC-DC converters, among others.

  2. Quiet Clean Short-haul Experimental Engine (QCSEE) over-the-wing control system design report

    NASA Technical Reports Server (NTRS)

    1977-01-01

    A control system incorporating a digital electronic control was designed for the over-the-wing engine. The digital electronic control serves as the primary controlling element for engine fuel flow and core compressor stator position. It also includes data monitoring capability, a unique failure indication and corrective action feature, and optional provisions for operating with a new type of servovalve designed to operate in response to a digital-type signal and to fail with its output device hydraulically locked into position.

  3. Digital Electronics for Nuclear Physics Experiments

    NASA Astrophysics Data System (ADS)

    Skulski, Wojtek; Hunter, David; Druszkiewicz, Eryk; Khaitan, Dev Ashish; Yin, Jun; Wolfs, Frank; SkuTek Instrumentation Team; Department of Physics; Astronomy, University of Rochester Team

    2015-10-01

    Future detectors in nuclear physics will use signal sampling as one of primary techniques of data acquisition. Using the digitized waveforms, the electronics can select events based on pulse shape, total energy, multiplicity, and the hit pattern. The DAQ for the LZ Dark Matter detector, now under development in Rochester, is a good example of the power of digital signal processing. This system, designed around 32-channel, FPGA-based, digital signal processors collects data from more than one thousand channels. The solutions developed for this DAQ can be applied to nuclear physics experiments. Supported by the Department of Energy Office of Science under Grant DE-SC0009543.

  4. Flight test of a full authority Digital Electronic Engine Control system in an F-15 aircraft

    NASA Technical Reports Server (NTRS)

    Barrett, W. J.; Rembold, J. P.; Burcham, F. W.; Myers, L.

    1981-01-01

    The Digital Electronic Engine Control (DEEC) system considered is a relatively low cost digital full authority control system containing selectively redundant components and fault detection logic with capability for accommodating faults to various levels of operational capability. The DEEC digital control system is built around a 16-bit, 1.2 microsecond cycle time, CMOS microprocessor, microcomputer system with approximately 14 K of available memory. Attention is given to the control mode, component bench testing, closed loop bench testing, a failure mode and effects analysis, sea-level engine testing, simulated altitude engine testing, flight testing, the data system, cockpit, and real time display.

  5. Carotid Artery Ultrasonographic Assessment in Patients from the Fremantle Diabetes Study Phase II with Carotid Bruits Detected by Electronic Auscultation

    PubMed Central

    Knapp, Arthur; Cetrullo, Violetta; Sillars, Brett A.; Lenzo, Nat; Davis, Wendy A.

    2014-01-01

    Abstract Background: Electronic auscultation appears superior to acoustic auscultation for identifying hemodynamic abnormalities. The aim of this study was to determine whether carotid bruits detected by electronic stethoscope in patients with diabetes are associated with stenoses and increased carotid intima-medial thickness (CIMT). Subjects and Methods: Fifty Fremantle Diabetes Study patients (mean±SD age, 73.7±10.0 years; 38.0% males) with a bruit found by electronic auscultation and 50 age- and sex-matched patients with normal carotid sounds were studied. The degree of stenosis and CIMT were assessed from duplex ultrasonography. Results: Patients with a bruit were more likely to have stenosis of ≥50% and CIMT of >1.0 mm than those without (odds ratios [95% confidence intervals]=14.0 [1.8–106.5] and 5.3 [1.8–15.3], respectively; both P=0.001). For the six patients with stenosis of ≥70%, five had a bruit, and one (with a known total occlusion) did not (odds ratio=5.0 [0.6–42.8]; P=0.22). The sensitivity and specificity of carotid bruit for stenoses of ≥50% were 88% and 58%, respectively; respective values for stenoses of ≥70% were 83% and 52%. The equivalent negative predictive values were 96% and 98%, and positive predictive values were 30% and 10%, respectively. Conclusions: Electronic recording of carotid sounds for later interpretation is convenient and reliable. Most patients with stenoses had an overlying bruit. Most bruits were false positives, but ultrasonography is justified to document extent of disease; CIMT measurement will identify increased vascular risk in most of these patients. The absence of a bruit was rarely a false-negative finding, suggesting that these patients can usually be reassured that they do not have hemodynamically important stenosis. PMID:24988112

  6. Bedside cardiac examination: constancy in a sea of change.

    PubMed

    Richardson, T R; Moody, J M

    2000-11-01

    The general trend in the recent literature has been to highlight the difficulties and shortcomings of the physical examination and to attribute these difficulties to deficiencies in training rather than to intrinsic weaknesses in auscultation itself. The call is for better training. Given the advice of the authors mentioned above, individual training may be warranted at the postgraduate level and in the large community of practicing internists and cardiologists. Although not proven, it is likely that individual training with computer technology, audiotape instruction, or simulator technology such as described in the following paragraphs would be effective at improving bedside clinical diagnosis and cost-effective patient care in the postgraduate, continuing medical education setting. The advances in auscultation during the last few years have been more incremental than fundamental. There is ongoing research into the mechanism of production of S3 and S4, and mathematical modeling techniques have recently been used with some success in evaluating the vibrations of S3 and S4 as forced, damped oscillations of a viscoelastic system. Analysis of sound energy with the technique of spectral waveform analysis, which investigates the frequency content of sound signals, has been used for many years in the study of cardiovascular sound. By the use of various methods of mathematical analysis, investigators have found potentially useful information in spectral sound patterns of prosthetic valves, murmur characteristics, and even potentially hemodynamic information from heart sounds. Despite the mathematical advances, there are still disturbing drawbacks to some of the analytic techniques, such as the production of mathematical terms containing "negative energy." Although the potential of obtaining significant clinical information from spectral analysis of heart sound recordings is attractive, the clinical usefulness of such techniques remains virtually nonexistent. Similar to the recent advances in auscultation, the technical advances in the design of the stethoscope have also been more incremental than fundamental. There are at least 3 recently introduced electronic stethoscopes that have the capability of amplification and filtration and that claim noise reduction. Because their introduction is recent, no information is available in the peer-review literature regarding their clinical performance; therefore their place in the clinical arena remains to be elucidated--perhaps a boon for patient care providers with specific hearing defects and perhaps useful in noisy clinical environments. Peer-review literature has not shown clear superiority of one type of acoustic stethoscope over another. The teaching of auscultation has been an area of recognized importance in patient care since the inception of auscultation as a medical art. Attempts to facilitate practitioner learning in the performance and interpretation of auscultation have advanced through the decades limited only by the technical infrastructure of the day. The availability of recorded heart sounds and murmurs appeared shortly after the availability of recording and playback devices, with first vinyl and later tape recordings. In 1974, technology was employed to create a virtual patient named "Harvey," an engineered cardiology patient simulator that reproduces many of the physical findings of the cardiology examination. Later, with the advent of commercially available CD-ROM devices, newer, better-integrated teaching devices have been developed, some of them outstanding in their clarity and quality. Despite the obvious value of such instructional aids that are best used in the individual setting, there is evidence that the classroom is still of significant value in teaching auscultation. However, nowhere else in the practice of medicine is a mentor approach more valuable than in learning auscultation. (ABSTRACT TRUNCATED)

  7. Development of the HIDEC inlet integration mode. [Highly Integrated Digital Electronic Control

    NASA Technical Reports Server (NTRS)

    Chisholm, J. D.; Nobbs, S. G.; Stewart, J. F.

    1990-01-01

    The Highly Integrated Digital Electronic Control (HIDEC) development program conducted at NASA-Ames/Dryden will use an F-15 test aircraft for flight demonstration. An account is presently given of the HIDEC Inlet Integration mode's design concept, control law, and test aircraft implementation, with a view to its performance benefits. The enhancement of performance is a function of the use of Digital Electronic Engine Control corrected engine airflow computations to improve the scheduling of inlet ramp positions in real time; excess thrust can thereby be increased by 13 percent at Mach 2.3 and 40,000 ft. Aircraft supportability is also improved through the obviation of inlet controllers.

  8. Analysis of pulmonary sounds for the diagnosis of interstitial lung diseases secondary to rheumatoid arthritis.

    PubMed

    Pancaldi, Fabrizio; Sebastiani, Marco; Cassone, Giulia; Luppi, Fabrizio; Cerri, Stefania; Della Casa, Giovanni; Manfredi, Andreina

    2018-05-01

    The diagnosis of interstitial lung diseases in patients affected by rheumatoid arthritis is fundamental to improving their survival rate. In particular, the average survival time of patients affected by rheumatoid arthritis with pulmonary implications is approximately 3 years. The gold standard for confirming the diagnosis of this disease is computer tomography. However, it is very difficult to raise diagnosis suspicion because the symptoms of the disease are extremely common in elderly people. The detection of the so-called velcro crackle in lung sounds can effectively raise the suspicion of an interstitial disease and speed up diagnosis. However, this task largely relies on the experience of physicians and has not yet been standardized in clinical practice. The diagnosis of interstitial lung diseases based on thorax auscultation still represents an underexplored field in the study of rheumatoid arthritis. In this study, we investigate the problem of the automatic detection of velcro crackle in lung sounds. In practice, the patient is auscultated using a digital stethoscope and the lung sounds are saved to a file. The acquired digital data are then analysed using a suitably developed algorithm. In particular, the proposed solution relies on the empirical observation that the audio bandwidth associated with velcro crackle is larger than that associated with healthy breath sounds. Experimental results from a database of 70 patients affected by rheumatoid arthritis demonstrate that the developed tool can outperform specialized physicians in terms of diagnosing pulmonary disorders. The overall accuracy of the proposed solution is 90.0%, with negative and positive predictive values of 95.0% and 83.3%, respectively, whereas the reliability of physician diagnosis is in the range of 60-70%. The devised algorithm represents an enabling technology for a novel approach to the diagnosis of interstitial lung diseases in patients affected by rheumatoid arthritis. Copyright © 2018 Elsevier Ltd. All rights reserved.

  9. Superconductor Digital-RF Receiver Systems

    NASA Astrophysics Data System (ADS)

    Mukhanov, Oleg A.; Kirichenko, Dmitri; Vernik, Igor V.; Filippov, Timur V.; Kirichenko, Alexander; Webber, Robert; Dotsenko, Vladimir; Talalaevskii, Andrei; Tang, Jia Cao; Sahu, Anubhav; Shevchenko, Pavel; Miller, Robert; Kaplan, Steven B.; Sarwana, Saad; Gupta, Deepnarayan

    Digital superconductor electronics has been experiencing rapid maturation with the emergence of smaller-scale, lower-cost communications applications which became the major technology drivers. These applications are primarily in the area of wireless communications, radar, and surveillance as well as in imaging and sensor systems. In these areas, the fundamental advantages of superconductivity translate into system benefits through novel Digital-RF architectures with direct digitization of wide band, high frequency radio frequency (RF) signals. At the same time the availability of relatively small 4K cryocoolers has lowered the foremost market barrier for cryogenically-cooled digital electronic systems. Recently, we have achieved a major breakthrough in the development, demonstration, and successful delivery of the cryocooled superconductor digital-RF receivers directly digitizing signals in a broad range from kilohertz to gigahertz. These essentially hybrid-technology systems combine a variety of superconductor and semiconductor technologies packaged with two-stage commercial cryocoolers: cryogenic Nb mixed-signal and digital circuits based on Rapid Single Flux Quantum (RSFQ) technology, room-temperature amplifiers, FPGA processing and control circuitry. The demonstrated cryocooled digital-RF systems are the world's first and fastest directly digitizing receivers operating with live satellite signals in X-band and performing signal acquisition in HF to L-band at ˜30GHz clock frequencies.

  10. Ex vivo accuracy of an apex locator using digital signal processing in primary teeth.

    PubMed

    Leonardo, Mário Roberto; da Silva, Lea Assed Bezerra; Nelson-Filho, Paulo; da Silva, Raquel Assed Bezerra; Lucisano, Marília Pacífico

    2009-01-01

    The purpose of this study was to evaluate ex vivo the accuracy an electronic apex locator during root canal length determination in primary molars. One calibrated examiner determined the root canal length in 15 primary molars (total=34 root canals) with different stages of root resorption. Root canal length was measured both visually with the placement of a K-file 1 mm short of the apical foramen or the apical resorption bevel, and electronically using an electronic apex locator (Digital Signal Processing). Data were analyzed statistically using the intraclass correlation (ICC) test. Comparing the actual and electronic root canal length measurements in the primary teeth showed a high correlation (ICC=0.95). The Digital Signal Processing apex locator is useful and accurate for apex foramen location during root canal length measurement in primary molars.

  11. Realization of Quantum Digital Signatures without the Requirement of Quantum Memory

    NASA Astrophysics Data System (ADS)

    Collins, Robert J.; Donaldson, Ross J.; Dunjko, Vedran; Wallden, Petros; Clarke, Patrick J.; Andersson, Erika; Jeffers, John; Buller, Gerald S.

    2014-07-01

    Digital signatures are widely used to provide security for electronic communications, for example, in financial transactions and electronic mail. Currently used classical digital signature schemes, however, only offer security relying on unproven computational assumptions. In contrast, quantum digital signatures offer information-theoretic security based on laws of quantum mechanics. Here, security against forging relies on the impossibility of perfectly distinguishing between nonorthogonal quantum states. A serious drawback of previous quantum digital signature schemes is that they require long-term quantum memory, making them impractical at present. We present the first realization of a scheme that does not need quantum memory and which also uses only standard linear optical components and photodetectors. In our realization, the recipients measure the distributed quantum signature states using a new type of quantum measurement, quantum state elimination. This significantly advances quantum digital signatures as a quantum technology with potential for real applications.

  12. Realization of quantum digital signatures without the requirement of quantum memory.

    PubMed

    Collins, Robert J; Donaldson, Ross J; Dunjko, Vedran; Wallden, Petros; Clarke, Patrick J; Andersson, Erika; Jeffers, John; Buller, Gerald S

    2014-07-25

    Digital signatures are widely used to provide security for electronic communications, for example, in financial transactions and electronic mail. Currently used classical digital signature schemes, however, only offer security relying on unproven computational assumptions. In contrast, quantum digital signatures offer information-theoretic security based on laws of quantum mechanics. Here, security against forging relies on the impossibility of perfectly distinguishing between nonorthogonal quantum states. A serious drawback of previous quantum digital signature schemes is that they require long-term quantum memory, making them impractical at present. We present the first realization of a scheme that does not need quantum memory and which also uses only standard linear optical components and photodetectors. In our realization, the recipients measure the distributed quantum signature states using a new type of quantum measurement, quantum state elimination. This significantly advances quantum digital signatures as a quantum technology with potential for real applications.

  13. The Comprehensive Evaluation of Electronic Learning Tools and Educational Software (CEELTES)

    ERIC Educational Resources Information Center

    Karolcík, Štefan; Cipková, Elena; Hrušecký, Roman; Veselský, Milan

    2015-01-01

    Despite the fact that digital technologies are more and more used in the learning and education process, there is still lack of professional evaluation tools capable of assessing the quality of used digital teaching aids in a comprehensive and objective manner. Construction of the Comprehensive Evaluation of Electronic Learning Tools and…

  14. Local Places, Global Connections: Libraries in the Digital Age. What's Going On Series.

    ERIC Educational Resources Information Center

    Benton Foundation, Washington, DC.

    Libraries have long been pivotal community institutions--public spaces where people can come together to learn, reflect, and interact. Today, information is rapidly spreading beyond books and journals to digital government archives, business databases, electronic sound and image collections, and the flow of electronic impulses over computer…

  15. Electronic Current Transducer (ECT) for high voltage dc lines

    NASA Astrophysics Data System (ADS)

    Houston, J. M.; Peters, P. H., Jr.; Summerayes, H. R., Jr.; Carlson, G. J.; Itani, A. M.

    1980-02-01

    The development of a bipolar electronic current transducer (ECT) for measuring the current in a high voltage dc (HVDC) power line at line potential is discussed. The design and construction of a free standing ECT for use on a 400 kV line having a nominal line current of 2000 A is described. Line current is measured by a 0.0001 ohm shunt whose voltage output is sampled by a 14 bit digital data link. The high voltage interface between line and ground is traversed by optical fibers which carry digital light signals as far as 300 m to a control room where the digital signal is converted back to an analog representation of the shunt voltage. Two redundant electronic and optical data links are used in the prototype. Power to operate digital and optical electronics and temperature controlling heaters at the line is supplied by a resistively and capacitively graded 10 stage cascade of ferrite core transformers located inside the hollow, SF6 filled, porcelain support insulator. The cascade is driven by a silicon controlled rectifier inverter which supplies about 100 W of power at 30 kHz.

  16. Deep Cryogenic Low Power 24 Bits Analog to Digital Converter with Active Reverse Cryostat

    NASA Astrophysics Data System (ADS)

    Turqueti, Marcos; Prestemon, Soren; Albright, Robert

    LBNL is developing an innovative data acquisition module for superconductive magnets where the front-end electronics and digitizer resides inside the cryostat. This electronic package allows conventional electronic technologies such as enhanced metal-oxide-semiconductor to work inside cryostats at temperatures as low as 4.2 K. This is achieved by careful management of heat inside the module that keeps the electronic envelop at approximately 85 K. This approach avoids all the difficulties that arise from changes in carrier mobility that occur in semiconductors at deep cryogenic temperatures. There are several advantages in utilizing this system. A significant reduction in electrical noise from signals captured inside the cryostat occurs due to the low temperature that the electronics is immersed in, reducing the thermal noise. The shorter distance that signals are transmitted before digitalization reduces pickup and cross-talk between channels. This improved performance in signal-to-noise rate by itself is a significant advantage. Another important advantage is the simplification of the feedthrough interface on the cryostat head. Data coming out of the cryostat is digital and serial, dramatically reducing the number of lines going through the cryostat feedthrough interface. It is important to notice that all lines coming out of the cryostat are digital and low voltage, reducing the possibility of electric breakdown inside the cryostat. This paper will explain in details the architecture and inner workings of this data acquisition system. It will also provide the performance of the analog to digital converter when the system is immersed in liquid helium, and in liquid nitrogen. Parameters such as power dissipation, integral non-linearity, effective number of bits, signal-to-noise and distortion, will be presented for both temperatures.

  17. Deep Cryogenic Low Power 24 Bits Analog to Digital Converter with Active Reverse Cryostat

    DOE PAGES

    Turqueti, Marcos; Prestemon, Soren; Albright, Robert

    2015-07-15

    LBNL is developing an innovative data acquisition module for superconductive magnets where the front-end electronics and digitizer resides inside the cryostat. This electronic package allows conventional electronic technologies such as enhanced metal–oxide–semiconductor to work inside cryostats at temperatures as low as 4.2 K. This is achieved by careful management of heat inside the module that keeps the electronic envelop at approximately 85 K. This approach avoids all the difficulties that arise from changes in carrier mobility that occur in semiconductors at deep cryogenic temperatures. There are several advantages in utilizing this system. A significant reduction in electrical noise from signalsmore » captured inside the cryostat occurs due to the low temperature that the electronics is immersed in, reducing the thermal noise. The shorter distance that signals are transmitted before digitalization reduces pickup and cross-talk between channels. This improved performance in signal-to-noise rate by itself is a significant advantage. Another important advantage is the simplification of the feedthrough interface on the cryostat head. Data coming out of the cryostat is digital and serial, dramatically reducing the number of lines going through the cryostat feedthrough interface. It is important to notice that all lines coming out of the cryostat are digital and low voltage, reducing the possibility of electric breakdown inside the cryostat. This paper will explain in details the architecture and inner workings of this data acquisition system. It will also provide the performance of the analog to digital converter when the system is immersed in liquid helium, and in liquid nitrogen. Parameters such as power dissipation, integral non-linearity, effective number of bits, signal-to-noise and distortion, will be presented for both temperatures.« less

  18. Digital Natives Revisited: Developing Digital Wisdom in the Modern University

    ERIC Educational Resources Information Center

    Harris, David

    2012-01-01

    The seminal work of Prensky on "digital natives" and "digital wisdom" is used to launch a broader discussion on the relations between electronic communication, higher education, and popular and elite culture. Prensky's critics commonly contrast his polarisations and generational divisions with a more complex picture of types of engagement with…

  19. Digital Tools: Enhancing Painting Skills among Malaysian Secondary School Students

    ERIC Educational Resources Information Center

    Samah, Azimah A.; Putih, Abu Talib; Hussin, Zaharah

    2016-01-01

    Digital tools refer to software applications in the production of artworks particularly in painting. Digital art work is materialized by using computers, software and a combination of computer peripherals such as tablet support. With the aid of electronic equipment, digital artists manipulate pixels or coloring with light to compose the work and…

  20. A Digital View of History: Drawing and Discussing Models of Historical Concepts

    ERIC Educational Resources Information Center

    Manfra, Meghan McGlinn; Coven, Robert M.

    2011-01-01

    Digital history refers to "the study of the past using a variety of electronically reproduced primary source texts, images, and artifacts as well as the constructed narratives, accounts, or presentations that result from digital historical inquiry." Access to digitized primary sources can promote active instruction in historical thinking. A…

  1. Secure communications system

    NASA Technical Reports Server (NTRS)

    Doland, G. D.

    1977-01-01

    System employs electronically randomized variant of quadraphase modulation and demodulation between two synchronized transceivers. System uses off-the-shelf components. It may be used with digital data, command signals, delta-modulated voice signals, digital television signals, or other data converted to digital form.

  2. A front-end readout Detector Board for the OpenPET electronics system

    NASA Astrophysics Data System (ADS)

    Choong, W.-S.; Abu-Nimeh, F.; Moses, W. W.; Peng, Q.; Vu, C. Q.; Wu, J.-Y.

    2015-08-01

    We present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, which allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is ``time stamped'' by a time-to-digital converter (TDC) implemented inside the FPGA . This digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.

  3. A front-end readout Detector Board for the OpenPET electronics system

    DOE PAGES

    Choong, W. -S.; Abu-Nimeh, F.; Moses, W. W.; ...

    2015-08-12

    Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, whichmore » allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.« less

  4. Digital Libraries and the Problem of Purpose [and] On DigiPaper and the Dissemination of Electronic Documents [and] DFAS: The Distributed Finding Aid Search System [and] Best Practices for Digital Archiving: An Information Life Cycle Approach [and] Mapping and Converting Essential Federal Geographic Data Committee (FGDC) Metadata into MARC21 and Dublin Core: Towards an Alternative to the FGDC Clearinghouse [and] Evaluating Website Modifications at the National Library of Medicine through Search Log analysis.

    ERIC Educational Resources Information Center

    Levy, David M.; Huttenlocher, Dan; Moll, Angela; Smith, MacKenzie; Hodge, Gail M.; Chandler, Adam; Foley, Dan; Hafez, Alaaeldin M.; Redalen, Aaron; Miller, Naomi

    2000-01-01

    Includes six articles focusing on the purpose of digital public libraries; encoding electronic documents through compression techniques; a distributed finding aid server; digital archiving practices in the framework of information life cycle management; converting metadata into MARC format and Dublin Core formats; and evaluating Web sites through…

  5. s48-e-007

    NASA Image and Video Library

    2013-01-15

    S48-E-007 (12 Sept 1991) --- Astronaut James F. Buchli, mission specialist, catches snack crackers as they float in the weightless environment of the earth-orbiting Discovery. This image was transmitted by the Electronic Still Camera, Development Test Objective (DTO) 648. The ESC is making its initial appearance on a Space Shuttle flight. Electronic still photography is a new technology that enables a camera to electronically capture and digitize an image with resolution approaching film quality. The digital image is stored on removable hard disks or small optical disks, and can be converted to a format suitable for downlink transmission or enhanced using image processing software. The Electronic Still Camera (ESC) was developed by the Man- Systems Division at the Johnson Space Center and is the first model in a planned evolutionary development leading to a family of high-resolution digital imaging devices. H. Don Yeates, JSC's Man-Systems Division, is program manager for the ESC. THIS IS A SECOND GENERATION PRINT MADE FROM AN ELECTRONICALLY PRODUCED NEGATIVE

  6. A nanocryotron comparator can connect single-flux-quantum circuits to conventional electronics

    NASA Astrophysics Data System (ADS)

    Zhao, Qing-Yuan; McCaughan, Adam N.; Dane, Andrew E.; Berggren, Karl K.; Ortlepp, Thomas

    2017-04-01

    Integration with conventional electronics offers a straightforward and economical approach to upgrading existing superconducting technologies, such as scaling up superconducting detectors into large arrays and combining single flux quantum (SFQ) digital circuits with semiconductor logic gates and memories. However, direct output signals from superconducting devices (e.g., Josephson junctions) are usually not compatible with the input requirements of conventional devices (e.g., transistors). Here, we demonstrate the use of a single three-terminal superconducting-nanowire device, called the nanocryotron (nTron), as a digital comparator to combine SFQ circuits with mature semiconductor circuits such as complementary metal oxide semiconductor (CMOS) circuits. Since SFQ circuits can digitize output signals from general superconducting devices and CMOS circuits can interface existing CMOS-compatible electronics, our results demonstrate the feasibility of a general architecture that uses an nTron as an interface to realize a ‘super-hybrid’ system consisting of superconducting detectors, superconducting quantum electronics, CMOS logic gates and memories, and other conventional electronics.

  7. Digital processing of radiographic images from PACS to publishing.

    PubMed

    Christian, M E; Davidson, H C; Wiggins, R H; Berges, G; Cannon, G; Jackson, G; Chapman, B; Harnsberger, H R

    2001-03-01

    Several studies have addressed the implications of filmless radiologic imaging on telemedicine, diagnostic ability, and electronic teaching files. However, many publishers still require authors to submit hard-copy images for publication of articles and textbooks. This study compares the quality digital images directly exported from picture archive and communications systems (PACS) to images digitized from radiographic film. The authors evaluated the quality of publication-grade glossy photographs produced from digital radiographic images using 3 different methods: (1) film images digitized using a desktop scanner and then printed, (2) digital images obtained directly from PACS then printed, and (3) digital images obtained from PACS and processed to improve sharpness prior to printing. Twenty images were printed using each of the 3 different methods and rated for quality by 7 radiologists. The results were analyzed for statistically significant differences among the image sets. Subjective evaluations of the filmless images found them to be of equal or better quality than the digitized images. Direct electronic transfer of PACS images reduces the number of steps involved in creating publication-quality images as well as providing the means to produce high-quality radiographic images in a digital environment.

  8. Digital Signature Management.

    ERIC Educational Resources Information Center

    Hassler, Vesna; Biely, Helmut

    1999-01-01

    Describes the Digital Signature Project that was developed in Austria to establish an infrastructure for applying smart card-based digital signatures in banking and electronic-commerce applications. Discusses the need to conform to international standards, an international certification infrastructure, and security features for a public directory…

  9. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Choong, W. -S.; Abu-Nimeh, F.; Moses, W. W.

    Here, we present a 16-channel front-end readout board for the OpenPET electronics system. A major task in developing a nuclear medical imaging system, such as a positron emission computed tomograph (PET) or a single-photon emission computed tomograph (SPECT), is the electronics system. While there are a wide variety of detector and camera design concepts, the relatively simple nature of the acquired data allows for a common set of electronics requirements that can be met by a flexible, scalable, and high-performance OpenPET electronics system. The analog signals from the different types of detectors used in medical imaging share similar characteristics, whichmore » allows for a common analog signal processing. The OpenPET electronics processes the analog signals with Detector Boards. Here we report on the development of a 16-channel Detector Board. Each signal is digitized by a continuously sampled analog-to-digital converter (ADC), which is processed by a field programmable gate array (FPGA) to extract pulse height information. A leading edge discriminator creates a timing edge that is "time stamped" by a time-to-digital converter (TDC) implemented inside the FPGA. In conclusion, this digital information from each channel is sent to an FPGA that services 16 analog channels, and then information from multiple channels is processed by this FPGA to perform logic for crystal lookup, DOI calculation, calibration, etc.« less

  10. The Heinz Electronic Library Interactive Online System (HELIOS): Building a Digital Archive Using Imaging, OCR, and Natural Language Processing Technologies.

    ERIC Educational Resources Information Center

    Galloway, Edward A.; Michalek, Gabrielle V.

    1995-01-01

    Discusses the conversion project of the congressional papers of Senator John Heinz into digital format and the provision of electronic access to these papers by Carnegie Mellon University. Topics include collection background, project team structure, document processing, scanning, use of optical character recognition software, verification…

  11. Aircraft Electronics Maintenance Training Simulator. Curriculum Outlines.

    ERIC Educational Resources Information Center

    Blackhawk Technical Coll., Janesville, WI.

    Instructional materials are provided for nine courses in an aircraft electronics maintenance training program. Courses are as follows: aviation basic electricity, direct current and alternating current electronics, basic avionic installations, analog electronics, digital electronics, microcomputer electronics, radio communications, aircraft…

  12. Cost effectiveness of a medical digital library.

    PubMed

    Roussel, F; Darmoni, S J; Thirion, B

    2001-01-01

    The rapid increase in the price of electronic journals has made the optimization of collection management an urgent task. As there is currently no standard procedure for the evaluation of this problem, we applied the Reading Factor (RF), an electronically computed indicator used for consultation of individual articles. The aim of our study was to assess the cost effective impact of modifications in our digital library (i.e. change of access from the Intranet to the Internet or change in editorial policy). The digital OVID library at Rouen University Hospital continues to be cost-effective in comparison with the interlibrary loan costs. Moreover, when electronic versions are offered alongside a limited amount of interlibrary loans, a reduction in library costs was observed.

  13. 21 CFR 1311.45 - Requirements for registrants that allow powers of attorney to obtain CSOS digital certificates...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... attorney to obtain CSOS digital certificates under their DEA registration. 1311.45 Section 1311.45 Food and... PRESCRIPTIONS (Eff. 6-1-10) Obtaining and Using Digital Certificates for Electronic Orders § 1311.45 Requirements for registrants that allow powers of attorney to obtain CSOS digital certificates under their DEA...

  14. 47 CFR 32.5999 - General.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... switching expense 6210 Non-digital switching expense 6211 Digital electronic switching expense 6212... Circuit equipment expense 6232 Information origination/termination expense 6310 Station apparatus expense...

  15. 47 CFR 32.5999 - General.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... switching expense 6210 Non-digital switching expense 6211 Digital electronic switching expense 6212... Circuit equipment expense 6232 Information origination/termination expense 6310 Station apparatus expense...

  16. 47 CFR 32.5999 - General.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... switching expense 6210 Non-digital switching expense 6211 Digital electronic switching expense 6212... Circuit equipment expense 6232 Information origination/termination expense 6310 Station apparatus expense...

  17. Modeling from Local to Subsystem Level Effects in Analog and Digital Circuits Due to Space Induced Single Event Transients

    NASA Technical Reports Server (NTRS)

    Perez, Reinaldo J.

    2011-01-01

    Single Event Transients in analog and digital electronics from space generated high energetic nuclear particles can disrupt either temporarily and sometimes permanently the functionality and performance of electronics in space vehicles. This work first provides some insights into the modeling of SET in electronic circuits that can be used in SPICE-like simulators. The work is then directed to present methodologies, one of which was developed by this author, for the assessment of SET at different levels of integration in electronics, from the circuit level to the subsystem level.

  18. Statistical EMC: A new dimension electromagnetic compatibility of digital electronic systems

    NASA Astrophysics Data System (ADS)

    Tsaliovich, Anatoly

    Electromagnetic compatibility compliance test results are used as a database for addressing three classes of electromagnetic-compatibility (EMC) related problems: statistical EMC profiles of digital electronic systems, the effect of equipment-under-test (EUT) parameters on the electromagnetic emission characteristics, and EMC measurement specifics. Open area test site (OATS) and absorber line shielded room (AR) results are compared for equipment-under-test highest radiated emissions. The suggested statistical evaluation methodology can be utilized to correlate the results of different EMC test techniques, characterize the EMC performance of electronic systems and components, and develop recommendations for electronic product optimal EMC design.

  19. Digital Libraries and the Continuum of Scholarly Communication.

    ERIC Educational Resources Information Center

    Borgman, Christine L.

    2000-01-01

    Explores the relationship between scholarly communication, an established research area receiving renewed interest, and digital libraries, a relatively new area of research. Stakeholders agree that the relationship structure inherent in scholarship has become unbalanced with the advent of electronic publishing, digital libraries, computer…

  20. An open real-time tele-stethoscopy system

    PubMed Central

    2012-01-01

    Background Acute respiratory infections are the leading cause of childhood mortality. The lack of physicians in rural areas of developing countries makes difficult their correct diagnosis and treatment. The staff of rural health facilities (health-care technicians) may not be qualified to distinguish respiratory diseases by auscultation. For this reason, the goal of this project is the development of a tele-stethoscopy system that allows a physician to receive real-time cardio-respiratory sounds from a remote auscultation, as well as video images showing where the technician is placing the stethoscope on the patient’s body. Methods A real-time wireless stethoscopy system was designed. The initial requirements were: 1) The system must send audio and video synchronously over IP networks, not requiring an Internet connection; 2) It must preserve the quality of cardiorespiratory sounds, allowing to adapt the binaural pieces and the chestpiece of standard stethoscopes, and; 3) Cardiorespiratory sounds should be recordable at both sides of the communication. In order to verify the diagnostic capacity of the system, a clinical validation with eight specialists has been designed. In a preliminary test, twelve patients have been auscultated by all the physicians using the tele-stethoscopy system, versus a local auscultation using traditional stethoscope. The system must allow listen the cardiac (systolic and diastolic murmurs, gallop sound, arrhythmias) and respiratory (rhonchi, rales and crepitations, wheeze, diminished and bronchial breath sounds, pleural friction rub) sounds. Results The design, development and initial validation of the real-time wireless tele-stethoscopy system are described in detail. The system was conceived from scratch as open-source, low-cost and designed in such a way that many universities and small local companies in developing countries may manufacture it. Only free open-source software has been used in order to minimize manufacturing costs and look for alliances to support its improvement and adaptation. The microcontroller firmware code, the computer software code and the PCB schematics are available for free download in a subversion repository hosted in SourceForge. Conclusions It has been shown that real-time tele-stethoscopy, together with a videoconference system that allows a remote specialist to oversee the auscultation, may be a very helpful tool in rural areas of developing countries. PMID:22917062

  1. Neglected evidence in idiopathic pulmonary fibrosis and the importance of early diagnosis and treatment.

    PubMed

    Cottin, Vincent; Richeldi, Luca

    2014-03-01

    In idiopathic pulmonary fibrosis (IPF), some facts or concepts based on substantial evidence, whilst implicit for learned subspecialists, have previously been neglected and/or not explicitly formulated or made accessible to a wider audience. IPF is strongly associated with cigarette smoking and is predominantly a disease of ageing. However, its cause(s) remain elusive and, thus, it is one of the most challenging diseases for the development of novel effective and safe therapies. With the approval of pirfenidone for patients with mild-to-moderate IPF, an earlier diagnosis of IPF is a prerequisite for earlier treatment and, potentially, improvement of the long-term clinical outcome of this progressive and ultimately fatal disease. An earlier diagnosis may be achieved in IPF by promoting thin-slice chest high-resolution computed tomography screening of interstitial lung disease as a "by-product" of large-scale lung cancer screening strategies in smokers, but other techniques, which have been neglected in the past, are now available. Lung auscultation and early identification of "velcro" crackles has been proposed as a key component of early diagnosis of IPF. An ongoing study is exploring correlations between lung sounds on auscultation obtained using electronic stethoscopes and high-resolution computed tomography patterns.

  2. Single-channel mixed signal blind source separation algorithm based on multiple ICA processing

    NASA Astrophysics Data System (ADS)

    Cheng, Xiefeng; Li, Ji

    2017-01-01

    Take separating the fetal heart sound signal from the mixed signal that get from the electronic stethoscope as the research background, the paper puts forward a single-channel mixed signal blind source separation algorithm based on multiple ICA processing. Firstly, according to the empirical mode decomposition (EMD), the single-channel mixed signal get multiple orthogonal signal components which are processed by ICA. The multiple independent signal components are called independent sub component of the mixed signal. Then by combining with the multiple independent sub component into single-channel mixed signal, the single-channel signal is expanded to multipath signals, which turns the under-determined blind source separation problem into a well-posed blind source separation problem. Further, the estimate signal of source signal is get by doing the ICA processing. Finally, if the separation effect is not very ideal, combined with the last time's separation effect to the single-channel mixed signal, and keep doing the ICA processing for more times until the desired estimated signal of source signal is get. The simulation results show that the algorithm has good separation effect for the single-channel mixed physiological signals.

  3. Development of electronic cinema projectors

    NASA Astrophysics Data System (ADS)

    Glenn, William E.

    2001-03-01

    All of the components for the electronic cinema are now commercially available. Sony has a high definition progressively scanned 24 frame per second electronic cinema camera. This can be recorded digitally on tape or film on hard drives in RAID recorders. Much of the post production processing is now done digitally by scanning film, processing it digitally, and recording it on film for release. Fiber links and satellites can transmit cinema program material to theaters in real time. RAID or tape recorders can play programs for viewing at a much lower cost than storage on film. Two companies now have electronic cinema projectors on the market. Of all of the components, the electronic cinema projector is the most challenging. Achieving the resolution, light, output, contrast ratio, and color rendition all at the same time without visible artifacts is a difficult task. Film itself is, of course, a form of light-valve. However, electronically modulated light uses other techniques rather than changes in density to control the light. The optical techniques that have been the basis for many electronic light-valves have been under development for over 100 years. Many of these techniques are based on optical diffraction to modulate the light. This paper will trace the history of these techniques and show how they may be extended to produce electronic cinema projectors in the future.

  4. Supervised Coursework as a Way of Improving Motivation in the Learning of Digital Electronics

    ERIC Educational Resources Information Center

    Rengel, R.; Martin, M. J.; Vasallo, B. G.

    2012-01-01

    This paper presents a series of activities and educational strategies related to the teaching of digital electronics in computer engineering. The main objective of these methodologies was to develop a final tutored coursework to be carried out by the students in small teams. This coursework was conceived as consisting of advanced problems or small…

  5. 77 FR 14955 - DoD Information Assurance Scholarship Program (IASP)

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-14

    ... IA and information technology (IT) management, technical, digital and multimedia forensics, cyber..., digital and multimedia forensics, electrical engineering, electronics engineering, information security...

  6. Digital cinema video compression

    NASA Astrophysics Data System (ADS)

    Husak, Walter

    2003-05-01

    The Motion Picture Industry began a transition from film based distribution and projection to digital distribution and projection several years ago. Digital delivery and presentation offers the prospect to increase the quality of the theatrical experience for the audience, reduce distribution costs to the distributors, and create new business opportunities for the theater owners and the studios. Digital Cinema also presents an opportunity to provide increased flexibility and security of the movies for the content owners and the theater operators. Distribution of content via electronic means to theaters is unlike any of the traditional applications for video compression. The transition from film-based media to electronic media represents a paradigm shift in video compression techniques and applications that will be discussed in this paper.

  7. Digital Health Services and Digital Identity in Alberta.

    PubMed

    McEachern, Aiden; Cholewa, David

    2017-01-01

    The Government of Alberta continues to improve delivery of healthcare by allowing Albertans to access their health information online. Alberta is the only province in Canada with provincial electronic health records for all its citizens. These records are currently made available to medical practitioners, but Alberta Health believes that providing Albertans access to their health records will transform the delivery of healthcare in Alberta. It is important to have a high level of assurance that the health records are provided to the correct Albertan. Alberta Health requires a way for Albertans to obtain a digital identity with a high level of identity assurance prior to releasing health records via the Personal Health Portal. Service Alberta developed the MyAlberta Digital ID program to provide a digital identity verification service. The Ministry of Health is leveraging MyAlberta Digital ID to enable Albertans to access their personal health records through the Personal Health Portal. The Government of Alberta is advancing its vision of patient-centred healthcare by enabling Albertans to access a trusted source for health information and their electronic health records using a secure digital identity.

  8. Astronaut Paul Weitz gets physical examination from Astronaut Joseph Kerwin

    NASA Technical Reports Server (NTRS)

    1973-01-01

    Astronaut Paul J. Weitz, Skylab 2 pilot, gets a physical examination by a fellow crewman during the 28-day Skylab 2 mission. Scientist-Astronaut Joseph P. Kerwin, Skylab 2 science pilot and a doctor of medicine, uses a stethoscope to check the Weitz's heartbeat. They are in the Orbital Workshop crew quarters of the Skylab 1 and 2 space station in Earth orbit. This photograph was taken by Charles Conrad Jr., Skylab 2 commander.

  9. Consumer protection act for digital products

    NASA Astrophysics Data System (ADS)

    Hampel, Viktor E.

    1996-03-01

    This report proposes a `Consumer Protection Act for Digital Products' to support electronic commerce and to control the increasing abuse and lack of security on the national information highways. Patterned after the `Food and Drug Act of 1906 (21 USC)' and subsequent legislation, a new agency similar to that of the FDA would have the authority `to develop administrative policy with regard to the safety, effectiveness, and labeling of digital products and their communications for human use, and to review and evaluate new applications of such products.' Specifically, it is proposed that standards, originally developed by the defense industry for the labeling, enveloping, and authentication of digital products delivered to the Government, be extended to promote global electronic commerce by protecting the intellectual property rights of producers, establishing their liability for the end-use of digital products, and give consumers means for informed decision making and purchase.

  10. Mark 3 wideband digital recorder in perspective

    NASA Technical Reports Server (NTRS)

    Hinteregger, H. F.

    1980-01-01

    The tape recorder used for the Mark 3 data acquisition and processing system is compared with earlier very long baseline interferometry recorders. Wideband 33-1/3 kbpi digital channel characteristics of instrumentation recorders and of a modern video cassette recorder are illustrated. Factors which influenced selection of the three major commercial components (transport, heads, and tape) are discussed. A brief functional description and the reasons for development of efficient signal electronics and necessary auxiliary control electronics are given. The design and operation of a digital bit synchronizer is illustrated as an example of the high degree of simplicity achieved.

  11. In-Orbit Performance of the Digital Electronics for the X-Ray Microcalorimeter Onboard the Hitomi Satellite

    NASA Astrophysics Data System (ADS)

    Tsujimoto, M.; Tashiro, M. S.; Ishisaki, Y.; Yamada, S.; Seta, H.; Mitsuda, K.; Boyce, K. R.; Eckart, M. E.; Kilbourne, C. A.; Leutenegger, M. A.; Porter, F. S.; Kelley, R. L.

    2018-03-01

    The pulse shape processor is the onboard digital electronics unit of the X-ray microcalorimeter instrument—the soft X-ray spectrometer—onboard the Hitomi satellite. It processes X-ray events using the optimum filtering with limited resources. It was operated for 36 days in orbit continuously without issues and met the requirement of processing a 150 s^{-1} event rate during the observation of bright sources. Here, we present the results obtained in orbit, focusing on its performance as the onboard digital signal processing unit of an X-ray microcalorimeter.

  12. 75 FR 6704 - In the Matter of Certain Mobile Telephones and Wireless Communication Devices Featuring Digital...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-02-10

    ... Respondents Samsung Electronics Co., Ltd., Samsung Electronics America, Inc., and Samsung Telecommunications... with respect to Samsung Electronics Co., Ltd., Samsung Electronics America, Inc., and Samsung... Electronics Co., Ltd., Samsung Electronics America, Inc., Samsung Telecommunications America, LLC...

  13. Advanced Electronic Systems. Curriculum Guide for Technology Education.

    ERIC Educational Resources Information Center

    Patrick, Dale R.

    This curriculum for a 1-semester or 1-year course in electronics is designed to take students from basic through advanced electronic systems. It covers several electronic areas, such as digital electronics, communication electronics, industrial process control, instrumentation, programmable controllers, and robotics. The guide contains…

  14. A Digital Library in the Mid-Nineties, Ahead or On Schedule?

    ERIC Educational Resources Information Center

    Dijkstra, Joost

    1994-01-01

    Discussion of the future possibilities of digital library systems highlights digital projects developed at Tilburg University (Netherlands). Topics addressed include online access to databases; electronic document delivery; agreements between libraries and Elsevier Science publishers to provide journal articles; full text document delivery; and…

  15. Electronic Library: A TERI Experiment.

    ERIC Educational Resources Information Center

    Kar, Debal C.; Deb, Subrata; Kumar, Satish

    2003-01-01

    Discusses the development of Electronic Library at TERI (The Energy and Resources Institute, New Delhi). Highlights include: hardware and software used; the digital library/Virtual Electronic Library; directory of Internet journals; virtual reference resources; electronic collection/Physical Electronic Library; downloaded online full-length…

  16. Digital disruption ?syndromes.

    PubMed

    Sullivan, Clair; Staib, Andrew

    2017-05-18

    The digital transformation of hospitals in Australia is occurring rapidly in order to facilitate innovation and improve efficiency. Rapid transformation can cause temporary disruption of hospital workflows and staff as processes are adapted to the new digital workflows. The aim of this paper is to outline various types of digital disruption and some strategies for effective management. A large tertiary university hospital recently underwent a rapid, successful roll-out of an integrated electronic medical record (EMR). We observed this transformation and propose several digital disruption "syndromes" to assist with understanding and management during digital transformation: digital deceleration, digital transparency, digital hypervigilance, data discordance, digital churn and post-digital 'depression'. These 'syndromes' are defined and discussed in detail. Successful management of this temporary digital disruption is important to ensure a successful transition to a digital platform. What is known about this topic? Digital disruption is defined as the changes facilitated by digital technologies that occur at a pace and magnitude that disrupt established ways of value creation, social interactions, doing business and more generally our thinking. Increasing numbers of Australian hospitals are implementing digital solutions to replace traditional paper-based systems for patient care in order to create opportunities for improved care and efficiencies. Such large scale change has the potential to create transient disruption to workflows and staff. Managing this temporary disruption effectively is an important factor in the successful implementation of an EMR. What does this paper add? A large tertiary university hospital recently underwent a successful rapid roll-out of an integrated electronic medical record (EMR) to become Australia's largest digital hospital over a 3-week period. We observed and assisted with the management of several cultural, behavioural and operational forms of digital disruption which lead us to propose some digital disruption 'syndromes'. The definition and management of these 'syndromes' are discussed in detail. What are the implications for practitioners? Minimising the temporary effects of digital disruption in hospitals requires an understanding that these digital 'syndromes' are to be expected and actively managed during large-scale transformation.

  17. Auger electron spectroscopy at high spatial resolution and nA primary beam currents

    NASA Technical Reports Server (NTRS)

    Todd, G.; Poppa, H.; Moorhead, D.; Bales, M.

    1975-01-01

    An experimental Auger microprobe system is described which incorporates a field-emission electron gun and total beam currents in the nanoampere range. The distinguishing characteristics of this system include a large multistation UHV specimen chamber, pulse counting and fully digital Auger signal-processing techniques, and digital referencing methods to eliminate the effects of beam instabilities. Some preliminary results obtained with this system are described, and it is concluded that field-emission electron sources can be used for high-resolution Auger electron spectroscopy with primary-beam spots of less than 100 nm and beam currents of the order of 1 nA.

  18. Design and performance of the readout electronics chain of the Delphi Forward Ring Imaging Cherenkov Detector

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Dam, P.; Nielsen, B.S.; Formenti, F.

    1992-10-01

    In this paper the Front End Readout electronics chain of the Forward Ring Imaging CHerenkov (FRICH) Detector used at the Delphi experiment of the Large Electron Positron (LEP) collider is presented. The system incorporates a wide band low noise preamplifier, mounted in the proximity of the MultiWire Proportional Chamber, an Amplifying-Discriminating-Multiple-xing FASTBUS unit for further signal amplification, discrimination and channel reduction and a LEP Time Digitizer FASTBUS unit for time digitization. The paper gives a general view of the detector and its electronics with particular emphasis on the novel characteristics and capabilities of the system.

  19. Digital processing with single electrons for arbitrary waveform generation of current

    NASA Astrophysics Data System (ADS)

    Okazaki, Yuma; Nakamura, Shuji; Onomitsu, Koji; Kaneko, Nobu-Hisa

    2018-03-01

    We demonstrate arbitrary waveform generation of current using a GaAs-based single-electron pump. In our experiment, a digital processing algorithm known as delta-sigma modulation is incorporated into single-electron pumping to generate a density-modulated single-electron stream, by which we demonstrate the generation of arbitrary waveforms of current including sinusoidal, square, and triangular waves with a peak-to-peak amplitude of approximately 10 pA and an output bandwidth ranging from dc to close to 1 MHz. The developed current generator can be used as the precise and calculable current reference required for measurements of current noise in low-temperature experiments.

  20. s48-e-013

    NASA Image and Video Library

    2012-11-08

    S48-E-013 (15 Sept 1991) --- The Upper Atmosphere Research Satellite (UARS) in the payload bay of the earth- orbiting Discovery. UARS is scheduled for deploy on flight day three of the STS-48 mission. Data from UARS will enable scientists to study ozone depletion in the stratosphere, or upper atmosphere. This image was transmitted by the Electronic Still Camera (ESC), Development Test Objective (DTO) 648. The ESC is making its initial appearance on a Space Shuttle flight. Electronic still photography is a new technology that enables a camera to electronically capture and digitize an image with resolution approaching film quality. The digital image is stored on removable hard disks or small optical disks, and can be converted to a format suitable for downlink transmission or enhanced using image processing software. The Electronic Still Camera (ESC) was developed by the Man- Systems Division at the Johnson Space Center and is the first model in a planned evolutionary development leading to a family of high-resolution digital imaging devices. H. Don Yeates, JSC's Man-Systems Division, is program manager for the ESC. THIS IS A SECOND GENERATION PRINT MADE FROM AN ELECTRONICALLY PRODUCED NEGATIVE.

  1. Coincidence electron/ion imaging with a fast frame camera

    NASA Astrophysics Data System (ADS)

    Li, Wen; Lee, Suk Kyoung; Lin, Yun Fei; Lingenfelter, Steven; Winney, Alexander; Fan, Lin

    2015-05-01

    A new time- and position- sensitive particle detection system based on a fast frame CMOS camera is developed for coincidence electron/ion imaging. The system is composed of three major components: a conventional microchannel plate (MCP)/phosphor screen electron/ion imager, a fast frame CMOS camera and a high-speed digitizer. The system collects the positional information of ions/electrons from a fast frame camera through real-time centroiding while the arrival times are obtained from the timing signal of MCPs processed by a high-speed digitizer. Multi-hit capability is achieved by correlating the intensity of electron/ion spots on each camera frame with the peak heights on the corresponding time-of-flight spectrum. Efficient computer algorithms are developed to process camera frames and digitizer traces in real-time at 1 kHz laser repetition rate. We demonstrate the capability of this system by detecting a momentum-matched co-fragments pair (methyl and iodine cations) produced from strong field dissociative double ionization of methyl iodide. We further show that a time resolution of 30 ps can be achieved when measuring electron TOF spectrum and this enables the new system to achieve a good energy resolution along the TOF axis.

  2. Is Higher Education Ready to Switch to Digital Course Materials? The Cost of Textbooks Is Driving Electronic Solutions

    ERIC Educational Resources Information Center

    Nelson, Mark A.

    2008-01-01

    Each year one of the biggest debates in higher education seems to be: Is this the year that electronic textbooks take off? E-reader devices are getting better. The inventory of digital content is expanding. Business models are emerging to support the needs of students, faculty members, and publishers. People are getting more comfortable with new…

  3. Murphy's law-if anything can go wrong, it will: Problems in phage electron microscopy.

    PubMed

    Ackermann, Hans-W; Tiekotter, Kenneth L

    2012-04-01

    The quality of bacteriophage electron microscopy appears to be on a downward course since the 1980s. This coincides with the introduction of digital electron microscopes and a general lowering of standards, possibly due to the disappearance of several world-class electron microscopists The most important problem seems to be poor contrast. Positive staining is frequently not recognized as an undesirable artifact. Phage parts, bacterial debris, and aberrant or damaged phage particles may be misdiagnosed as bacterial viruses. Digital electron microscopes often seem to be operated without magnification control because this is difficult and inconvenient. In summary, most phage electron microscopy problems may be attributed to human failure. Journals are a last-ditch defense and have a heavy responsibility in selecting competent reviewers and rejecting, or not, unsatisfactory articles.

  4. In situ measurements of thunderstorm electrical properties

    NASA Technical Reports Server (NTRS)

    Marshall, T. C.

    1982-01-01

    An airplane sensor to measure the charge, size and two dimensional shape of precipitation particles and large cloud particles was developed. The basic design of the instrument includes: the transducers and analog electronics, the analog to digital conversion electronics and a microprocessor based system to run the electronics and load the digital data onto magnetic tape. Prototype instrumentation for the proposed lightning mapper satellite was tested by flying it in a U-2 aircraft over severe storms in Oklahoma. Flight data are compared to data from ground based instruments.

  5. Distributed Interoperable Metadata Registry; How Do Physicists Use an E-Print Archive? Implications for Institutional E-Print Services; A Framework for Building Open Digital Libraries; Implementing Digital Sanborn Maps for Ohio: OhioLINK and OPLIN Collaborative Project.

    ERIC Educational Resources Information Center

    Blanchi, Christophe; Petrone, Jason; Pinfield, Stephen; Suleman, Hussein; Fox, Edward A.; Bauer, Charly; Roddy, Carol Lynn

    2001-01-01

    Includes four articles that discuss a distributed architecture for managing metadata that promotes interoperability between digital libraries; the use of electronic print (e-print) by physicists; the development of digital libraries; and a collaborative project between two library consortia in Ohio to provide digital versions of Sanborn Fire…

  6. 76 FR 78866 - Exemption to Prohibition on Circumvention of Copyright Protection Systems for Access Control...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-12-20

    ... initiated a rulemaking proceeding in accordance with provisions added by the Digital Millennium Copyright... available in digital copies. Proponent: The Open Book Alliance. 2. Literary works, distributed electronically, that: (1) Contain digital rights management and/or other access controls which either prevent the...

  7. 36 CFR 1235.48 - What documentation must agencies transfer with electronic records?

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... digital geospatial data files can include metadata that conforms to the Federal Geographic Data Committee's Content Standards for Digital Geospatial Metadata, as specified in Executive Order 12906 of April... number (301) 837-2903 for digital photographs and metadata, or the National Archives and Records...

  8. 36 CFR 1235.48 - What documentation must agencies transfer with electronic records?

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... digital geospatial data files can include metadata that conforms to the Federal Geographic Data Committee's Content Standards for Digital Geospatial Metadata, as specified in Executive Order 12906 of April... number (301) 837-2903 for digital photographs and metadata, or the National Archives and Records...

  9. 36 CFR § 1235.48 - What documentation must agencies transfer with electronic records?

    Code of Federal Regulations, 2013 CFR

    2013-07-01

    ... digital geospatial data files can include metadata that conforms to the Federal Geographic Data Committee's Content Standards for Digital Geospatial Metadata, as specified in Executive Order 12906 of April... number (301) 837-2903 for digital photographs and metadata, or the National Archives and Records...

  10. 36 CFR 1235.48 - What documentation must agencies transfer with electronic records?

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... digital geospatial data files can include metadata that conforms to the Federal Geographic Data Committee's Content Standards for Digital Geospatial Metadata, as specified in Executive Order 12906 of April... number (301) 837-2903 for digital photographs and metadata, or the National Archives and Records...

  11. 36 CFR 1235.48 - What documentation must agencies transfer with electronic records?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... digital geospatial data files can include metadata that conforms to the Federal Geographic Data Committee's Content Standards for Digital Geospatial Metadata, as specified in Executive Order 12906 of April... number (301) 837-2903 for digital photographs and metadata, or the National Archives and Records...

  12. 75 FR 34782 - Exelon Generation Company, LLC, Braidwood Station, Independent Spent Fuel Installation Order...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    ..., to request (1) a digital ID certificate, which allows the participant (or its counsel or... NRC- issued digital ID certificate). Based upon this information, the Secretary will establish an... electronic docket. Information about applying for a digital ID certificate is available on NRC's public Web...

  13. Fundamentals of Digital Logic.

    ERIC Educational Resources Information Center

    Noell, Monica L.

    This course is designed to prepare electronics personnel for further training in digital techniques, presenting need to know information that is basic to any maintenance course on digital equipment. It consists of seven study units: (1) binary arithmetic; (2) boolean algebra; (3) logic gates; (4) logic flip-flops; (5) nonlogic circuits; (6)…

  14. Digital circuits for computer applications: A compilation

    NASA Technical Reports Server (NTRS)

    1972-01-01

    The innovations in this updated series of compilations dealing with electronic technology represent a carefully selected collection of digital circuits which have direct application in computer oriented systems. In general, the circuits have been selected as representative items of each section and have been included on their merits of having universal applications in digital computers and digital data processing systems. As such, they should have wide appeal to the professional engineer and scientist who encounter the fundamentals of digital techniques in their daily activities. The circuits are grouped as digital logic circuits, analog to digital converters, and counters and shift registers.

  15. Barriers and facilitators to adoption of soft copy interpretation from the user perspective: Lessons learned from filmless radiology for slideless pathology

    PubMed Central

    Patterson, Emily S.; Rayo, Mike; Gill, Carolina; Gurcan, Metin N.

    2011-01-01

    Background: Adoption of digital images for pathological specimens has been slower than adoption of digital images in radiology, despite a number of anticipated advantages for digital images in pathology. In this paper, we explore the factors that might explain this slower rate of adoption. Materials and Method: Semi-structured interviews on barriers and facilitators to the adoption of digital images were conducted with two radiologists, three pathologists, and one pathologist's assistant. Results: Barriers and facilitators to adoption of digital images were reported in the areas of performance, workflow-efficiency, infrastructure, integration with other software, and exposure to digital images. The primary difference between the settings was that performance with the use of digital images as compared to the traditional method was perceived to be higher in radiology and lower in pathology. Additionally, exposure to digital images was higher in radiology than pathology, with some radiologists exclusively having been trained and/or practicing with digital images. The integration of digital images both improved and reduced efficiency in routine and non-routine workflow patterns in both settings, and was variable across the different organizations. A comparison of these findings with prior research on adoption of other health information technologies suggests that the barriers to adoption of digital images in pathology are relatively tractable. Conclusions: Improving performance using digital images in pathology would likely accelerate adoption of innovative technologies that are facilitated by the use of digital images, such as electronic imaging databases, electronic health records, double reading for challenging cases, and computer-aided diagnostic systems. PMID:21383925

  16. Fully digital data processing during cardiovascular implantable electronic device follow-up in a high-volume tertiary center.

    PubMed

    Staudacher, Ingo; Nalpathamkalam, Asha Roy; Uhlmann, Lorenz; Illg, Claudius; Seehausen, Sebastian; Akhavanpoor, Mohammadreza; Buchauer, Anke; Geis, Nicolas; Lugenbiel, Patrick; Schweizer, Patrick A; Xynogalos, Panagiotis; Zylla, Maura M; Scholz, Eberhard; Zitron, Edgar; Katus, Hugo A; Thomas, Dierk

    2017-10-11

    Increasing numbers of patients with cardiovascular implantable electronic devices (CIEDs) and limited follow-up capacities highlight unmet challenges in clinical electrophysiology. Integrated software (MediConnect ® ) enabling fully digital processing of device interrogation data has been commercially developed to facilitate follow-up visits. We sought to assess feasibility of fully digital data processing (FDDP) during ambulatory device follow-up in a high-volume tertiary hospital to provide guidance for future users of FDDP software. A total of 391 patients (mean age, 70 years) presenting to the outpatient department for routine device follow-up were analyzed (pacemaker, 44%; implantable cardioverter defibrillator, 39%; cardiac resynchronization therapy device, 16%). Quality of data transfer and follow-up duration were compared between digital (n = 265) and manual processing of device data (n = 126). Digital data import was successful, complete and correct in 82% of cases when early software versions were used. When using the most recent software version the rate of successful digital data import increased to 100%. Software-based import of interrogation data was complete and without failure in 97% of cases. The mean duration of a follow-up visit did not differ between the two groups (digital 18.7 min vs. manual data transfer 18.2 min). FDDP software was successfully implemented into the ambulatory follow-up of patients with implanted pacemakers and defibrillators. Digital data import into electronic patient management software was feasible and supported the physician's workflow. The total duration of follow-up visits comprising technical device interrogation and clinical actions was not affected in the present tertiary center outpatient cohort.

  17. Flight evaluation of a digital electronic engine control system in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Myers, L. P.; Mackall, K. G.; Burcham, F. W., Jr.; Walter, W. A.

    1982-01-01

    Benefits provided by a full-authority digital engine control are related to improvements in engine efficiency, performance, and operations. An additional benefit is the capability of detecting and accommodating failures in real time and providing engine-health diagnostics. The digital electronic engine control (DEEC), is a full-authority digital engine control developed for the F100-PW-100 turbofan engine. The DEEC has been flight tested on an F-15 aircraft. The flight tests had the objective to evaluate the DEEC hardware and software over the F-15 flight envelope. A description is presented of the results of the flight tests, which consisted of nonaugmented and augmented throttle transients, airstarts, and backup control operations. The aircraft, engine, DEEC system, and data acquisition and reduction system are discussed.

  18. Emergency Preparedness Plan. DeWitt Army Community Hospital, Fort Belvoir, Virginia,

    DTIC Science & Technology

    1997-12-31

    demand, dispatch at least one Respiratory Specialist (91V) to the ER rn Department of Familv Practice or senior representative will: (1) /Wnni™ and...be prepared for are: a. Two (2) messengers/runners to the EOC and Triage area(s). b. One or more Respiratory Specialist (91V) to the ER. c. A...Depressors 1 bx Shave Prep Set 50 ea Skin Closure, Adhesive 2 bx Stethoscope 5 ea Dental Mirrors 2 ea Nasal Speculum 2 ea Betadine Surgi-prep Sponge

  19. An Intelligent Pattern Recognition System Based on Neural Network and Wavelet Decomposition for Interpretation of Heart Sounds

    DTIC Science & Technology

    2001-10-25

    wavelet decomposition of signals and classification using neural network. Inputs to the system are the heart sound signals acquired by a stethoscope in a...Proceedings. pp. 415–418, 1990. [3] G. Ergun, “An intelligent diagnostic system for interpretation of arterpartum fetal heart rate tracings based on ANNs and...AN INTELLIGENT PATTERN RECOGNITION SYSTEM BASED ON NEURAL NETWORK AND WAVELET DECOMPOSITION FOR INTERPRETATION OF HEART SOUNDS I. TURKOGLU1, A

  20. Development of digital shade guides for color assessment using a digital camera with ring flashes.

    PubMed

    Tung, Oi-Hong; Lai, Yu-Lin; Ho, Yi-Ching; Chou, I-Chiang; Lee, Shyh-Yuan

    2011-02-01

    Digital photographs taken with cameras and ring flashes are commonly used for dental documentation. We hypothesized that different illuminants and camera's white balance setups shall influence color rendering of digital images and affect the effectiveness of color matching using digital images. Fifteen ceramic disks of different shades were fabricated and photographed with a digital camera in both automatic white balance (AWB) and custom white balance (CWB) under either light-emitting diode (LED) or electronic ring flash. The Commission Internationale d'Éclairage L*a*b* parameters of the captured images were derived from Photoshop software and served as digital shade guides. We found significantly high correlation coefficients (r² > 0.96) between the respective spectrophotometer standards and those shade guides generated in CWB setups. Moreover, the accuracy of color matching of another set of ceramic disks using digital shade guides, which was verified by ten operators, improved from 67% in AWB to 93% in CWB under LED illuminants. Probably, because of the inconsistent performance of the flashlight and specular reflection, the digital images captured under electronic ring flash in both white balance setups revealed less reliable and relative low-matching ability. In conclusion, the reliability of color matching with digital images is much influenced by the illuminants and camera's white balance setups, while digital shade guides derived under LED illuminants with CWB demonstrate applicable potential in the fields of color assessments.

  1. Strike Up the Score: Deriving Searchable and Playable Digital Formats from Sheet Music; Smart Objects and Open Archives; Building the Archives of the Future: Advanced in Preserving Electronic Records at the National Archives and Records Administration; From the Digitized to the Digital Library.

    ERIC Educational Resources Information Center

    Choudhury, G. Sayeed; DiLauro, Tim; Droettboom, Michael; Fujinaga, Ichiro; MacMillan, Karl; Nelson, Michael L.; Maly, Kurt; Thibodeau, Kenneth; Thaller, Manfred

    2001-01-01

    These articles describe the experiences of the Johns Hopkins University library in digitizing their collection of sheet music; motivation for buckets, Smart Object, Dumb Archive (SODA) and the Open Archives Initiative (OAI), and initial experiences using them in digital library (DL) testbeds; requirements for archival institutions, the National…

  2. OPTOELECTRONICS, FIBER OPTICS, AND OTHER ASPECTS OF QUANTUM ELECTRONICS: Nonlinear optical devices: basic elements of a future optical digital computer?

    NASA Astrophysics Data System (ADS)

    Fischer, R.; Müller, R.

    1989-08-01

    It is shown that nonlinear optical devices are the most promising elements for an optical digital supercomputer. The basic characteristics of various developed nonlinear elements are presented, including bistable Fabry-Perot etalons, interference filters, self-electrooptic effect devices, quantum-well devices utilizing transitions between the lowest electron states in the conduction band of GaAs, etc.

  3. [INVITED] Laser-induced forward transfer: A high resolution additive manufacturing technology

    NASA Astrophysics Data System (ADS)

    Delaporte, Philippe; Alloncle, Anne-Patricia

    2016-04-01

    Among the additive manufacturing techniques, laser-induced forward transfer addresses the challenges of printing thin films in solid phase or small volume droplets in liquid phase with very high resolution. This paper reviews the physics of this process and explores the pros and cons of this technology versus other digital printing technologies. The main field of applications are printed electronics, organic electronics and tissue engineering, and the most promising short terms ones concern digital laser printing of sensors and conductive tracks. Future directions and emerging areas of interest are discussed such as printing solid from a liquid phase and 3D digital nanomanufacturing.

  4. Investigation of a nozzle instability on an F100 engine equipped with a digital electronic engine control

    NASA Technical Reports Server (NTRS)

    Burcham, F. W., Jr.; Zeller, J. R.

    1984-01-01

    An instability in the nozzle of the F100 engine, equipped with a digital electronic engine control (DEEC), was observed during a flight evaluation on an F-15 aircraft. The instability occurred in the upper left hand corner (ULMC) of the flight envelope during augmentation. The instability was not predicted by stability analysis, closed-loop simulations of the the engine, or altitude testing of the engine. The instability caused stalls and augmentor blowouts. The nozzle instability and the altitude testing are described. Linear analysis and nonlinear digital simulation test results are presented. Software modifications on further flight test are discussed.

  5. Flight testing the digital electronic engine control in the F-15 airplane

    NASA Technical Reports Server (NTRS)

    Myers, L. P.

    1984-01-01

    The digital electronic engine control (DEEC) is a full-authority digital engine control developed for the F100-PW-100 turbofan engine which was flight tested on an F-15 aircraft. The DEEC hardware and software throughout the F-15 flight envelope was evaluated. Real-time data reduction and data display systems were implemented. New test techniques and stronger coordination between the propulsion test engineer and pilot were developed which produced efficient use of test time, reduced pilot work load, and greatly improved quality data. The engine pressure ratio (EPR) control mode is demonstrated. It is found that the nonaugmented throttle transients and engine performance are satisfactory.

  6. Overview of the CCITT Recommendations for Synchronous Digital Hierarchy

    DTIC Science & Technology

    1991-10-01

    Recommendations for8 Synchronous Digital Hierarchy DCK RAPPORTENCEN’TRiLEAD-A245 680 Frederikkazerne, Geb. 140EN 1111 iNTelefcron: 070-3166394/6395... Synchronous Digital Hierarchy author(s) P.P. Copeland institute TNO Physics and Electronics Laboratory date October 1991 NDRO no A90KLu635 no in pow...recent International Consultative Committee for Telephone and Telegraph (CCITT) Recommendations for the Synchronous Digital Hierarchy (SDH). The

  7. 75 FR 24998 - In the Matter of Florida Power and Light Company: Turkey Point Nuclear Plant; Independent Spent...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-05-06

    ..., to request (1) a digital ID certificate, which allows the participant (or its counsel or... NRC- issued digital ID certificate). Based upon this information, the Secretary will establish an... electronic docket. Information about applying for a digital ID certificate is available on NRC's public Web...

  8. Do You Hear What I See? Assessing Accessibility of Digital Commons and CONTENTdm

    ERIC Educational Resources Information Center

    Walker, Wendy; Keenan, Teressa

    2015-01-01

    This article discusses the accessibility of two content management systems, Berkeley Electronic Press's Digital Commons and OCLC's CONTENTdm, widely used in libraries to host institutional repository and digital collections content. Based on observations by a visually impaired student who used the JAWS screen reader to view the design and display…

  9. A Typology for Analyzing Digital Curricula in Mathematics Education

    ERIC Educational Resources Information Center

    Choppin, Jeffrey; Carson, Cynthia; Borys, Zenon; Cerosaletti, Cathleen; Gillis, Rob

    2014-01-01

    Digital content is increasingly present in U.S. K-12 classrooms, with a current push by federal officials to increase the rate at which digital textbooks are adopted. While some teachers' use of electronic resources involves locating activities and lessons from various internet sites, textbook and educational software companies have begun to…

  10. Digitizing a Cultural Heritage--The Key Issue for Preservation and Electronic Publishing.

    ERIC Educational Resources Information Center

    Bogen, Manfred; Bonkowski, Christian; Borowski, Marion; Loffler, Jobst

    This paper describes a realization approach to evaluate the best fitting service provider in the context of "The Digital Beethoven House" pilot project, involving the digitizing of a composer-referred collection of colored manuscripts and other sources at the Beethoven House Association (Germany). Practical hints for museums are provided…

  11. Empowering Student Voice through Interactive Design and Digital Making

    ERIC Educational Resources Information Center

    Kim, Yanghee; Searle, Kristin

    2017-01-01

    Over the last two decades online technology and digital media have provided space for students to participate and express their voices. This paper further explores how new digital technologies, such as humanoid robots and wearable electronics, can be used to offer additional spaces where students' voices are heard. In these spaces, young students…

  12. IoT-Forensics Meets Privacy: Towards Cooperative Digital Investigations

    PubMed Central

    Lopez, Javier

    2018-01-01

    IoT-Forensics is a novel paradigm for the acquisition of electronic evidence whose operation is conditioned by the peculiarities of the Internet of Things (IoT) context. As a branch of computer forensics, this discipline respects the most basic forensic principles of preservation, traceability, documentation, and authorization. The digital witness approach also promotes such principles in the context of the IoT while allowing personal devices to cooperate in digital investigations by voluntarily providing electronic evidence to the authorities. However, this solution is highly dependent on the willingness of citizens to collaborate and they may be reluctant to do so if the sensitive information within their personal devices is not sufficiently protected when shared with the investigators. In this paper, we provide the digital witness approach with a methodology that enables citizens to share their data with some privacy guarantees. We apply the PRoFIT methodology, originally defined for IoT-Forensics environments, to the digital witness approach in order to unleash its full potential. Finally, we show the feasibility of a PRoFIT-compliant digital witness with two use cases. PMID:29414864

  13. IoT-Forensics Meets Privacy: Towards Cooperative Digital Investigations.

    PubMed

    Nieto, Ana; Rios, Ruben; Lopez, Javier

    2018-02-07

    IoT-Forensics is a novel paradigm for the acquisition of electronic evidence whose operation is conditioned by the peculiarities of the Internet of Things (IoT) context. As a branch of computer forensics, this discipline respects the most basic forensic principles of preservation, traceability, documentation, and authorization. The digital witness approach also promotes such principles in the context of the IoT while allowing personal devices to cooperate in digital investigations by voluntarily providing electronic evidence to the authorities. However, this solution is highly dependent on the willingness of citizens to collaborate and they may be reluctant to do so if the sensitive information within their personal devices is not sufficiently protected when shared with the investigators. In this paper, we provide the digital witness approach with a methodology that enables citizens to share their data with some privacy guarantees. We apply the PRoFIT methodology, originally defined for IoT-Forensics environments, to the digital witness approach in order to unleash its full potential. Finally, we show the feasibility of a PRoFIT-compliant digital witness with two use cases.

  14. Development of a digital method for neutron/gamma-ray discrimination based on matched filtering

    NASA Astrophysics Data System (ADS)

    Korolczuk, S.; Linczuk, M.; Romaniuk, R.; Zychor, I.

    2016-09-01

    Neutron/gamma-ray discrimination is crucial for measurements with detectors sensitive to both neutron and gamma-ray radiation. Different techniques to discriminate between neutrons and gamma-rays based on pulse shape analysis are widely used in many applications, e.g., homeland security, radiation dosimetry, environmental monitoring, fusion experiments, nuclear spectroscopy. A common requirement is to improve a radiation detection level with a high detection reliability. Modern electronic components, such as high speed analog to digital converters and powerful programmable digital circuits for signal processing, allow us to develop a fully digital measurement system. With this solution it is possible to optimize digital signal processing algorithms without changing any electronic components in an acquisition signal path. We report on results obtained with a digital acquisition system DNG@NCBJ designed at the National Centre for Nuclear Research. A 2'' × 2'' EJ309 liquid scintillator was used to register mixed neutron and gamma-ray radiation from PuBe sources. A dedicated algorithm for pulse shape discrimination, based on real-time filtering, was developed and implemented in hardware.

  15. Digital rights language support for evolving digital cinema requirements

    NASA Astrophysics Data System (ADS)

    Orri, Xavier; Mas, Joan-Maria; Macq, Benoit M. M.

    2003-06-01

    Digital cinema can be defined as the digital electronic distribution and display of theatrical film content or live material to the theatre. However, this simple definition does not reflect the complex mesh of balanced business relationships between the different parties involved in the worldwide cinematic distribution. Its transition from an analogue to a digital business will happen progressively, starting with only content being digitally distributed and going until an all-digital business. From these facts derive strong requirements on digital rights management (DRM) systems for digital cinema and therefore on the digital rights language supporting it. This paper explores the requirements imposed by the cinematic distribution model and by its progressive transition to digital, and the impact these have on digital rights languages. We analyze the support provided by different digital rights languages, identifying weaknesses and exploring solutions in fulfilling the requirements of the digital cinema distribution model.

  16. Digital signature feasibility study

    DOT National Transportation Integrated Search

    2008-06-01

    The purpose of this study was to assess the advantages and disadvantages of using digital signatures to assist the Arizona Department of Transportation in conducting business. The Department is evaluating the potential of performing more electronic t...

  17. Digitization, Integration and Preservation of Technical and Historical Information: The Case of INTA, the National Institute for Aerospace Technique of Spain

    NASA Astrophysics Data System (ADS)

    Merida Martín, F.; Paz Otero, S.

    2007-10-01

    During the last two years the INTA -- National Institute for Aerospace Technique -- library has been improving different areas related to the information management processes, such as those related to cataloguing, dissemination of technical information, centralization at the Library of all relevant documents and information applicable to scientific research within our organization, implementation of library web services, etc. As part of these processes of modernization of services that the INTA Library is carrying out, a project of digitization of both technical documentation and historical records of the Institute has been defined. The goal is to achieve the total digitization of technical documents and historical papers through the year 2006, and provide access for the resulting electronic collection to the Spanish aerospace community. For the development of the project a deep study of the state of the art in digitization and preservation matters has been conducted. That study covers the different aspects of such a project that could be experienced, such as the risk of data loss, the bandwidth needed to guarantee access to this huge quantity of electronic documentation, the fragility of the digital media, the rapid obsolescence of hardware and software, etc. Also the project is going to assume the new reality of documents that are not originating in paper format, but are digital-born, and how to integrate all the electronic documents in one system, fulfilling the same standards and using the same available technology.

  18. Use of globally unique identifiers (GUIDs) to link herbarium specimen records to physical specimens.

    PubMed

    Nelson, Gil; Sweeney, Patrick; Gilbert, Edward

    2018-02-01

    With the advent of the U.S. National Science Foundation's Advancing Digitization of Biodiversity Collections program and related worldwide digitization initiatives, the rate of herbarium specimen digitization in the United States has expanded exponentially. As the number of electronic herbarium records proliferates, the importance of linking these records to the physical specimens they represent as well as to related records from other sources will intensify. Although a rich and diverse literature has developed over the past decade that addresses the use of specimen identifiers for facilitating linking across the internet, few implementable guidelines or recommended practices for herbaria have been advanced. Here we review this literature with the express purpose of distilling a specific set of recommendations especially tailored to herbarium specimen digitization, curation, and management. We argue that associating globally unique identifiers (GUIDs) with physical herbarium specimens and including these identifiers in all electronic records about those specimens is essential to effective digital data curation. We also address practical applications for ensuring these associations.

  19. A Value-Added Framework for Analyzing Electronic and Print Publishing.

    ERIC Educational Resources Information Center

    Perritt, Henry H., Jr.

    1991-01-01

    Discusses changes in the publishing industry resulting from digital electronic networks and optical storage technologies, and explains attributes of information products as types of value for both print and electronic contexts. Electronic products necessary for a shift from paper to electronic formats are identified, and legal issues are…

  20. Test of GET Electronics for the CHIMERA and FARCOS multi-detectors

    NASA Astrophysics Data System (ADS)

    De Luca, S.; Acosta, L.; Auditore, L.; Boiano, C.; Cardella, G.; Castoldi, A.; D'Andrea, M.; De Filippo, E.; Dell'Aquila, D.; Fichera, F.; Gnoffo, B.; Guazzoni, C.; Lanzalone, G.; Lombardo, I.; Martorana, N. S.; Minniti, T.; Norella, S.; Pagano, A.; Pagano, E. V.; Papa, M.; Pirrone, S.; Politi, G.; Quattrocchi, L.; Rizzo, F.; Russotto, P.; Saccà, G.; Trifirò, A.; Trimarchi, M.; Verde, G.; Vigilante, M.

    2017-11-01

    In this paper we present the results of the tests on the new digital electronics GET (General Electronics for Tpc), which will be used for the readout of the CsI(Tl) detectors of CHIMERA (Charged Heavy Ion Mass and Energy Resolving Array) and for the new correlator FARCOS (Femtoscope ARray for COrrelations and Spectroscopy). The new electronics allows us to digitize the full waveform of the signals produced by the detector. Among its features it is worth noticing the compactness and low power consumption (5W for 256 channels). Tests have been performed with pulsers, radioactive sources and ion beams. With such electronics very good results in energy resolution and isotope separation of the detected fragments were obtained, by using both hardware and software filters.

  1. Models for formation and choice of variants for organizing digital electronics manufacturing

    NASA Astrophysics Data System (ADS)

    Korshunov, G. I.; Lapkova, M. Y.; Polyakov, S. L.; Frolova, E. A.

    2018-03-01

    The directions of organizing digital electronics manufacturing are considered by the example of surface mount technology. The basic equipment choice has to include not only individual characteristics, but also mutual influence of individual machines and the results of design for manufacturing. Application of special cases of the Utility function which are complicated in the general representation of polynomial functions are proposed for estimation of product quality in a staged automation.

  2. A History Update of the U. S. Army Engineer Topographic Laboratories Fort Belvoir, Virginia 1979-1983

    DTIC Science & Technology

    1988-01-01

    these patterns had to be arranged in one of a number of spatial data formats. To a computer, electronic " noise " created by errant impulses in the...quality photographs can be deblurred using digital image manipulation techniques. The special congressional committee investigating the...capability. UNAMACE errors were of two kinds. Electronic noise recorded along with digital elevation data created false elevations . Also , UNAMACE could

  3. Digital electronic engine control fault detection and accommodation flight evaluation

    NASA Technical Reports Server (NTRS)

    Baer-Ruedhart, J. L.

    1984-01-01

    The capabilities and performance of various fault detection and accommodation (FDA) schemes in existing and projected engine control systems were investigated. Flight tests of the digital electronic engine control (DEEC) in an F-15 aircraft show discrepancies between flight results and predictions based on simulation and altitude testing. The FDA methodology and logic in the DEEC system, and the results of the flight failures which occurred to date are described.

  4. Specifying and calibrating instrumentations for wideband electronic power measurements. [in switching circuits

    NASA Technical Reports Server (NTRS)

    Lesco, D. J.; Weikle, D. H.

    1980-01-01

    The wideband electric power measurement related topics of electronic wattmeter calibration and specification are discussed. Tested calibration techniques are described in detail. Analytical methods used to determine the bandwidth requirements of instrumentation for switching circuit waveforms are presented and illustrated with examples from electric vehicle type applications. Analog multiplier wattmeters, digital wattmeters and calculating digital oscilloscopes are compared. The instrumentation characteristics which are critical to accurate wideband power measurement are described.

  5. Accurate determination of lattice parameters based on Niggli reduced cell theory by using digitized electron diffraction micrograph.

    PubMed

    Yang, Yi; Cai, Canying; Lin, Jianguo; Gong, Lunjun; Yang, Qibin

    2017-05-01

    In this paper, we used Niggli reduced cell theory to determine lattice constants of a micro/nano crystal by using electron diffraction patterns. The Niggli reduced cell method enhanced the accuracy of lattice constant measurement obviously, because the lengths and the angles of lattice vectors of a primitive cell can be measured directly on the electron micrographs instead of a double tilt holder. With the aid of digitized algorithm and least square optimization by using three digitized micrographs, a valid reciprocal Niggli reduced cell number can be obtained. Thus a reciprocal and real Bravais lattices are acquired. The results of three examples, i.e., Mg 4 Zn 7 , an unknown phase (Precipitate phase in nickel-base superalloy) and Ba 4 Ti 13 O 30 showed that the maximum errors are 1.6% for lengths and are 0.3% for angles. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Digital Audio Radio Field Tests

    NASA Technical Reports Server (NTRS)

    Hollansworth, James E.

    1997-01-01

    Radio history continues to be made at the NASA Lewis Research Center with the beginning of phase two of Digital Audio Radio testing conducted by the Consumer Electronic Manufacturers Association (a sector of the Electronic Industries Association and the National Radio Systems Committee) and cosponsored by the Electronic Industries Association and the National Association of Broadcasters. The bulk of the field testing of the four systems should be complete by the end of October 1996, with results available soon thereafter. Lewis hosted phase one of the testing process, which included laboratory testing of seven proposed digital audio radio systems and modes (see the following table). Two of the proposed systems operate in two modes, thus making a total of nine systems for testing. These nine systems are divided into the following types of transmission: in-band on channel (IBOC), in-band adjacent channel (IBAC), and new bands - the L-band (1452 to 1492 MHz) and the S-band (2310 to 2360 MHz).

  7. Digital pulse processing and electronic noise analysis for improving energy resolutions in planar TlBr detectors

    NASA Astrophysics Data System (ADS)

    Tada, Tsutomu; Hitomi, Keitaro; Tanaka, Tomonobu; Wu, Yan; Kim, Seong-Yun; Yamazaki, Hiromichi; Ishii, Keizo

    2011-05-01

    Digital pulse processing and electronic noise analysis are proposed for improving energy resolution in planar thallium bromide (TlBr) detectors. An energy resolution of 5.8% FWHM at 662 keV was obtained from a 0.5 mm thick planar TlBr detector at room temperature using a digitizer with a sampling rate of 100 MS/s and 8 bit resolution. The electronic noise in the detector-preamplifier system was measured as a function of pulse shaping time in order to investigate the optimum shaping time for the detector. The depth of interaction (DOI) in TlBr detectors for incident gamma-rays was determined by taking the ratio of pulse heights for fast-shaped to slow-shaped signals. FWHM energy resolution of the detector was improved from 5.8% to 4.2% by implementing depth correction and by using the obtained optimum shaping time.

  8. Electronics for Deep Space Cryogenic Applications

    NASA Technical Reports Server (NTRS)

    Patterson, R. L.; Hammond, A.; Dickman, J. E.; Gerber, S. S.; Elbuluk, M. E.; Overton, E.

    2002-01-01

    Deep space probes and planetary exploration missions require electrical power management and control systems that are capable of efficient and reliable operation in very cold temperature environments. Typically, in deep space probes, heating elements are used to keep the spacecraft electronics near room temperature. The utilization of power electronics designed for and operated at low temperature will contribute to increasing efficiency and improving reliability of space power systems. At NASA Glenn Research Center, commercial-off-the-shelf devices as well as developed components are being investigated for potential use at low temperatures. These devices include semiconductor switching devices, magnetics, and capacitors. Integrated circuits such as digital-to-analog and analog-to-digital converters, DC/DC converters, operational amplifiers, and oscillators are also being evaluated. In this paper, results will be presented for selected analog-to-digital converters, oscillators, DC/DC converters, and pulse width modulation (PWM) controllers.

  9. Hierarchical CAD Tools for Radiation Hardened Mixed Signal Electronic Circuits

    DTIC Science & Technology

    2005-01-28

    11 Figure 3: Schematic of Analog and Digital Components 12 Figure 4: Dose Rate Syntax 14 Figure 5: Single Event Effects (SEE) Syntax 15 Figure 6...Harmony-AMS simulation of a Digital Phase Locked Loop 19 Figure 10: SEE results from DPLL Simulation 20 Figure 11: Published results used for validation...analog and digital circuitry. Combining the analog and digital elements onto a single chip has several advantages, but also creates unique challenges

  10. Optical modulator system

    NASA Technical Reports Server (NTRS)

    Brand, J.

    1972-01-01

    The fabrication, test, and delivery of an optical modulator system which will operate with a mode-locked Nd:YAG laser indicating at either 1.06 or 0.53 micrometers is discussed. The delivered hardware operates at data rates up to 400 Mbps and includes a 0.53 micrometer electrooptic modulator, a 1.06 micrometer electrooptic modulator with power supply and signal processing electronics with power supply. The modulators contain solid state drivers which accept digital signals with MECL logic levels, temperature controllers to maintain a stable thermal environment for the modulator crystals, and automatic electronic compensation to maximize the extinction ratio. The modulators use two lithium tantalate crystals cascaded in a double pass configuration. The signal processing electronics include encoding electronics which are capable of digitizing analog signals between the limit of + or - 0.75 volts at a maximum rate of 80 megasamples per second with 5 bit resolution. The digital samples are serialized and made available as a 400 Mbps serial NRZ data source for the modulators. A pseudorandom (PN) generator is also included in the signal processing electronics. This data source generates PN sequences with lengths between 31 bits and 32,767 bits in a serial NRZ format at rates up to 400 Mbps.

  11. Develop security architecture for both in-house healthcare information systems and electronic patient record

    NASA Astrophysics Data System (ADS)

    Zhang, Jianguo; Chen, Xiaomeng; Zhuang, Jun; Jiang, Jianrong; Zhang, Xiaoyan; Wu, Dongqing; Huang, H. K.

    2003-05-01

    In this paper, we presented a new security approach to provide security measures and features in both healthcare information systems (PACS, RIS/HIS), and electronic patient record (EPR). We introduced two security components, certificate authoring (CA) system and patient record digital signature management (DSPR) system, as well as electronic envelope technology, into the current hospital healthcare information infrastructure to provide security measures and functions such as confidential or privacy, authenticity, integrity, reliability, non-repudiation, and authentication for in-house healthcare information systems daily operating, and EPR exchanging among the hospitals or healthcare administration levels, and the DSPR component manages the all the digital signatures of patient medical records signed through using an-symmetry key encryption technologies. The electronic envelopes used for EPR exchanging are created based on the information of signers, digital signatures, and identifications of patient records stored in CAS and DSMS, as well as the destinations and the remote users. The CAS and DSMS were developed and integrated into a RIS-integrated PACS, and the integration of these new security components is seamless and painless. The electronic envelopes designed for EPR were used successfully in multimedia data transmission.

  12. Living in a ``stethoscope'': burrow-acoustics promote auditory specializations in subterranean rodents

    NASA Astrophysics Data System (ADS)

    Lange, Simone; Burda, Hynek; Wegner, Regina E.; Dammann, Philip; Begall, Sabine; Kawalika, Mathias

    2007-02-01

    Subterranean mammals rely to a great extent on audition for communication and to be alerted to danger. The only hitherto published report on burrow acoustics revealed that in tunnels of blind mole-rats ( Spalax ehrenbergi), airborne sounds of 440 Hz propagated best whereas lower and higher frequencies were effectively attenuated. Morpho-functional analyses classify the ear of subterranean mammals as a low-sensitivity and low-frequency device. Concordantly, hearing is characterized by low sensitivity and a restricted frequency range tuned to low frequencies (0.5-4 kHz). Some authors considered the restricted hearing in subterranean mammals vestigial and degenerate due to under-stimulation. In contrast to this view stand a rich (mostly low-frequency) vocal repertoire and progressive structural specializations of the middle and inner ear. Thus, other authors considered these hearing characteristics adaptive. To test the hypothesis that acoustical environment in burrows of different species of subterranean mammals is similar, we measured sound attenuation in burrows of Fukomys mole-rats (formerly known as Cryptomys, cf. Kock et al. 2006) of two differently sized species at different locations in Zambia. We show that in these burrows, low-frequency sounds (200-800 Hz) are not only least attenuated but also their amplitude may be amplified like in a stethoscope (up to two times over 1 m). We suggest that hearing sensitivity has decreased during evolution of subterranean mammals to avoid over-stimulation of the ear in their natural environment.

  13. Early detection and control of an Acinetobacter baumannii multi-resistant outbreak in a hospital in Quito, Ecuador.

    PubMed

    Cartelle Gestal, Monica; Zurita, Jeannete; Gualpa, Gabriela; Gonzalez, Cecibel; Paz Y Mino, Ariane

    2016-12-30

    Acinetobacter baumannii (ABA) is an important opportunistic pathogen associated with high mortality rates in intensive care units (ICUs). An outbreak in the ICU of a secondary-level hospital in Quito, Ecuador, occurred during April and May 2015 and was successfully controlled. Enterobacterial repetitive intergenic consensus polymerase chain reaction (ERIC-PCR) and repetitive element palindromic (REP)-PCR was conducted on all isolates recovered from patients, as well as environmental samples, to confirm the presence of an outbreak. A case-control study was conducted by comparing the clinical histories of the affected patients and of control patients present in the ICU during the outbreak period who did not present a positive culture for ABA. Five patients were infected and two were colonized with the same clonal strain of ABA, which was also identified on the stethoscope and a monitor associated with an isolation room. Statistical analysis of case histories did not identify any additional risk factors, but the outbreak was initiated by one patient in the isolation room of the ICU who was infected with the outbreak strain. All patients who ocupied that room after the index case tested positive for at least one culture of ABA. The outbreak strain was found on the stethoscope, and a subclone was found on the monitor of that room. Having access to basic equipment will enable well-trained professionals to rapidly detect and initiate the control process of an outbreak, saving lives and money spent on nosocomial infection treatments.

  14. Cardio-Pulmonary Stethoscope: Clinical Validation With Heart Failure and Hemodialysis Patients.

    PubMed

    Iskander, Magdy F; Seto, Todd B; Perron, Ruthsenne Rg; Lim, Eunjung; Qazi, Farhan

    2018-05-01

    The purpose of this study is to evaluate the accuracy of a noninvasive radiofrequency-based device, the Cardio-Pulmonary Stethoscope (CPS), to monitor heart and respiration rates, and detect changes in lung water content in human experiments and clinical trials. Three human populations (healthy subjects ( ), heart failure (), and hemodialysis () patients) were enrolled in this study. The study was conducted at the University of Hawaii and the Queen's Medical Center in Honolulu, HI, USA. Measurement of heart and respiration rates for all patients was compared with standard FDA - approved monitoring methods. For lung water measurements, CPS data were compared with simultaneous pulmonary capillary wedge pressure (PCWP) measurements for heart failure patients, and with change in weight of extracted fluid for hemodialysis patients. Statistical correlation methods (Pearson, mixed, and intraclass) were used to compare the data and examine accuracy of CPS results. Results show that heart and respiration rates of all patients have excellent correlation factors, r≥0.9. Comparisons with fluid removed during hemodialysis treatment showed correlation factor of to 1, while PCWP measurements of heart failure patients had correlation factor of to 0.97. These results suggest that CPS technology accurately quantifies heart and respiration rates and measure fluid changes in the lungs. The CPS has the potential to accurately monitor lung fluid status noninvasively and continuously in a clinical and outpatient setting. Early and efficient management of lung fluid status is key in managing chronic conditions such heart failure, pulmonary hypertension, and acute respiration distress syndrome.

  15. 75 FR 34787 - In the Matter of Luminant Generation Company LLC; Comanche Peak Steam Electric Station...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-06-18

    [email protected] , or by telephone at (301) 415-1677, to request (1) a digital ID certificate, which allows the... its counsel or representative, already holds an NRC- issued digital ID certificate). Based upon this... Secretary has not already established an electronic docket. Information about applying for a digital ID...

  16. Measuring the Coefficient of Restitution Using a Digital Oscilloscope

    ERIC Educational Resources Information Center

    Wadhwa, Ajay

    2009-01-01

    We introduce a new method of determining the coefficient of restitution (COR) of a ball-surface combination by using the sound produced by the impact/collision of the ball with the surface. Using a digital electronic circuit, the electrical signal is amplified and fed to a digital storage oscilloscope through a relay circuit for measuring the time…

  17. What a Difference a Year Makes.

    ERIC Educational Resources Information Center

    Birt, Carina

    1998-01-01

    Addresses the growth of signatures in document management. Describes the three basic types of electronic signature technology: image signatures, digital signatures, and digitized biometric signatures. Discusses legal and regulatory acceptability and bringing signatures into document management. (AEF)

  18. Digital History: Problem of Creation of Resources

    NASA Astrophysics Data System (ADS)

    Uhlír, Zdenêk

    This paper is based on the reference background of historical librarianship, so that it does not address astronomical problems per se. In this respect we can see the historical astronomical material at three different levels: first, as factual data preserved from the past or as that we can take today as factual data; second, as evidence of the acquisition and explication of this factual material, i.e. history of astronomy as science; and third, as the inclusion of astronomical progress into historical material in general, and, in another sense, into the development of intellectual thought. At present we are witnessing a transition from an environment of predominantly printed material into an electronic-digital environment. In connection with this important change in communication there is also a new conceptualization of information and knowledge. This must be responded to by a conversion of existing sources and the creation of new ones. This wider horizon will require fundamental changes in the domain of the historical librarian. Creation of historical resources in the electronic-digital environment has three aspects: first, it is a permanent creation of digital image copies; second, building a catalogue as an access point common for both original and subsidiary documents; third, production of full-text databases of bibliographic and factual databases as well as comments-monographs. Owing to the fact that there does not exist in the electronic-digital environment any document in the strict sense of the word, it increases the importance of the context of data and the information itself becomes an interpretation. Also, due to the fact that the subject itself appears as a theme at more than one level, the knowledge becomes an interpretation at each next level. Thus the resources in the electronic-digital environment have the potential for an indirect, indefinite utilization. So it is not enough to just represent data in an objective way, but it is also necessary to prepare them such that they allow interpretation in various contexts (the sphere of information) and also for various disciplines (the sphere of knowledge). It demands both inter-disciplinary and trans-disciplinary approaches not just a concentration on a certain discipline and specialization. From all of this follows a need of changing both the library and the information preparation for the information network of the electronic-digital environment.

  19. Single-electron random-number generator (RNG) for highly secure ubiquitous computing applications

    NASA Astrophysics Data System (ADS)

    Uchida, Ken; Tanamoto, Tetsufumi; Fujita, Shinobu

    2007-11-01

    Since the security of all modern cryptographic techniques relies on unpredictable and irreproducible digital keys generated by random-number generators (RNGs), the realization of high-quality RNG is essential for secure communications. In this report, a new RNG, which utilizes single-electron phenomena, is proposed. A room-temperature operating silicon single-electron transistor (SET) having nearby an electron pocket is used as a high-quality, ultra-small RNG. In the proposed RNG, stochastic single-electron capture/emission processes to/from the electron pocket are detected with high sensitivity by the SET, and result in giant random telegraphic signals (GRTS) on the SET current. It is experimentally demonstrated that the single-electron RNG generates extremely high-quality random digital sequences at room temperature, in spite of its simple configuration. Because of its small-size and low-power properties, the single-electron RNG is promising as a key nanoelectronic device for future ubiquitous computing systems with highly secure mobile communication capabilities.

  20. Innovation Online Teaching Module Plus Digital Engineering Kit with Proteus Software through Hybrid Learning Method to Improve Student Skills

    NASA Astrophysics Data System (ADS)

    Kholis, Nur; Syariffuddien Zuhrie, Muhamad; Rahmadian, Reza

    2018-04-01

    Demands the competence (competence) needs of the industry today is a competent workforce to the field of work. However, during this lecture material Digital Engineering (Especially Digital Electronics Basics and Digital Circuit Basics) is limited to the delivery of verbal form of lectures (classical method) is dominated by the Lecturer (Teacher Centered). Though the subject of Digital Engineering requires learning tools and is required understanding of electronic circuits, digital electronics and high logic circuits so that learners can apply in the world of work. One effort to make it happen is by creating an online teaching module and educational aids (Kit) with the help of Proteus software that can improve the skills of learners. This study aims to innovate online teaching modules plus kits in Proteus-assisted digital engineering courses through hybrid learning approaches to improve the skills of learners. The process of innovation is done by considering the skills and mastery of the technology of students (students) Department of Electrical Engineering - Faculty of Engineering – Universitas Negeri Surabaya to produce quality graduates Use of online module plus Proteus software assisted kit through hybrid learning approach. In general, aims to obtain adequate results with affordable cost of investment, user friendly, attractive and interactive (easily adapted to the development of Information and Communication Technology). With the right design, implementation and operation, both in the form of software both in the form of Online Teaching Module, offline teaching module, Kit (Educational Viewer), and e-learning learning content (both online and off line), the use of the three tools of the expenditure will be able to adjust the standard needs of Information and Communication Technology world, both nationally and internationally.

  1. Optical information processing at NASA Ames Research Center

    NASA Technical Reports Server (NTRS)

    Reid, Max B.; Bualat, Maria G.; Cho, Young C.; Downie, John D.; Gary, Charles K.; Ma, Paul W.; Ozcan, Meric; Pryor, Anna H.; Spirkovska, Lilly

    1993-01-01

    The combination of analog optical processors with digital electronic systems offers the potential of tera-OPS computational performance, while often requiring less power and weight relative to all-digital systems. NASA is working to develop and demonstrate optical processing techniques for on-board, real time science and mission applications. Current research areas and applications under investigation include optical matrix processing for space structure vibration control and the analysis of Space Shuttle Main Engine plume spectra, optical correlation-based autonomous vision for robotic vehicles, analog computation for robotic path planning, free-space optical interconnections for information transfer within digital electronic computers, and multiplexed arrays of fiber optic interferometric sensors for acoustic and vibration measurements.

  2. Digital radiography and electronic data storage from the perspective of legal requirements for record keeping.

    PubMed

    Figgener, L; Runte, C

    2003-12-01

    In some countries physicians and dentists are required by law to keep medical and dental records. These records not only serve as personal notes and memory aids but have to be in accordance with the necessary standard of care and may be used as evidence in litigation. Inadequate, incomplete or even missing records can lead to reversal of the burden of proof, resulting in a dramatically reduced chance of successful defence in litigation. The introduction of digital radiography and electronic data storage presents a new problem with respect to legal evidence, since digital data can easily be manipulated and industry is now required to provide adequate measures to prevent manipulations and forgery.

  3. Thin, nearly wireless adaptive optical device

    NASA Technical Reports Server (NTRS)

    Knowles, Gareth (Inventor); Hughes, Eli (Inventor)

    2008-01-01

    A thin, nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.

  4. Thin, nearly wireless adaptive optical device

    NASA Technical Reports Server (NTRS)

    Knowles, Gareth (Inventor); Hughes, Eli (Inventor)

    2007-01-01

    A thin, nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.

  5. Thin nearly wireless adaptive optical device

    NASA Technical Reports Server (NTRS)

    Knowles, Gareth J. (Inventor); Hughes, Eli (Inventor)

    2009-01-01

    A thin nearly wireless adaptive optical device capable of dynamically modulating the shape of a mirror in real time to compensate for atmospheric distortions and/or variations along an optical material is provided. The device includes an optical layer, a substrate, at least one electronic circuit layer with nearly wireless architecture, an array of actuators, power electronic switches, a reactive force element, and a digital controller. Actuators are aligned so that each axis of expansion and contraction intersects both substrate and reactive force element. Electronics layer with nearly wireless architecture, power electronic switches, and digital controller are provided within a thin-film substrate. The size and weight of the adaptive optical device is solely dominated by the size of the actuator elements rather than by the power distribution system.

  6. Electronic polarization-division demultiplexing based on digital signal processing in intensity-modulation direct-detection optical communication systems.

    PubMed

    Kikuchi, Kazuro

    2014-01-27

    We propose a novel configuration of optical receivers for intensity-modulation direct-detection (IM · DD) systems, which can cope with dual-polarization (DP) optical signals electrically. Using a Stokes analyzer and a newly-developed digital signal-processing (DSP) algorithm, we can achieve polarization tracking and demultiplexing in the digital domain after direct detection. Simulation results show that the power penalty stemming from digital polarization manipulations is negligibly small.

  7. Digital electronic engine control history

    NASA Technical Reports Server (NTRS)

    Putnam, T. W.

    1984-01-01

    Full authority digital electronic engine controls (DEECs) were studied, developed, and ground tested because of projected benefits in operability, improved performance, reduced maintenance, improved reliability, and lower life cycle costs. The issues of operability and improved performance, however, are assessed in a flight test program. The DEEC on a F100 engine in an F-15 aircraft was demonstrated and evaluated. The events leading to the flight test program are chronicled and important management and technical results are identified.

  8. Real-time in-flight thrust calculation on a digital electronic engine control-equipped F100 engine in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Ray, R. J.; Myers, L. P.

    1984-01-01

    Computer algorithms which calculate in-flight engine and aircraft performance real-time are discussed. The first step was completed with the implementation of a real-time thrust calculation program on a digital electronic engine control (DEEC) equiped F100 engine in an F-15 aircraft. The in-flight thrust modifications that allow calculations to be performed in real-time, to compare results to predictions, are presented.

  9. Digital-Electronic/Optical Apparatus Would Recognize Targets

    NASA Technical Reports Server (NTRS)

    Scholl, Marija S.

    1994-01-01

    Proposed automatic target-recognition apparatus consists mostly of digital-electronic/optical cross-correlator that processes infrared images of targets. Infrared images of unknown targets correlated quickly with images of known targets. Apparatus incorporates some features of correlator described in "Prototype Optical Correlator for Robotic Vision System" (NPO-18451), and some of correlator described in "Compact Optical Correlator" (NPO-18473). Useful in robotic system; to recognize and track infrared-emitting, moving objects as variously shaped hot workpieces on conveyor belt.

  10. Biological Signal Processing with a Genetic Toggle Switch

    PubMed Central

    Hillenbrand, Patrick; Fritz, Georg; Gerland, Ulrich

    2013-01-01

    Complex gene regulation requires responses that depend not only on the current levels of input signals but also on signals received in the past. In digital electronics, logic circuits with this property are referred to as sequential logic, in contrast to the simpler combinatorial logic without such internal memory. In molecular biology, memory is implemented in various forms such as biochemical modification of proteins or multistable gene circuits, but the design of the regulatory interface, which processes the input signals and the memory content, is often not well understood. Here, we explore design constraints for such regulatory interfaces using coarse-grained nonlinear models and stochastic simulations of detailed biochemical reaction networks. We test different designs for biological analogs of the most versatile memory element in digital electronics, the JK-latch. Our analysis shows that simple protein-protein interactions and protein-DNA binding are sufficient, in principle, to implement genetic circuits with the capabilities of a JK-latch. However, it also exposes fundamental limitations to its reliability, due to the fact that biological signal processing is asynchronous, in contrast to most digital electronics systems that feature a central clock to orchestrate the timing of all operations. We describe a seemingly natural way to improve the reliability by invoking the master-slave concept from digital electronics design. This concept could be useful to interpret the design of natural regulatory circuits, and for the design of synthetic biological systems. PMID:23874595

  11. 77 FR 67290 - Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer Electronics Equipment

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ...-126] Basic Service Tier Encryption Compatibility Between Cable Systems and Consumer Electronics... between consumer electronics equipment (such as digital television sets) and newly encrypted cable service... Act''), Congress sought to make sure that consumer electronics equipment could receive cable...

  12. Digital Tidbits

    ERIC Educational Resources Information Center

    Kumaran, Maha; Geary, Joe

    2011-01-01

    Technology has transformed libraries. There are digital libraries, electronic collections, online databases and catalogs, ebooks, downloadable books, and much more. With free technology such as social websites, newspaper collections, downloadable online calendars, clocks and sticky notes, online scheduling, online document sharing, and online…

  13. 36 CFR 1235.44 - What general transfer requirements apply to electronic records?

    Code of Federal Regulations, 2014 CFR

    2014-07-01

    ... 20740, phone number (301) 837-3420. (c) When transferring digital photographs and their accompanying... Archives Services Division (NWCS) for digital photographs, 8601 Adelphi Road, College Park, MD 20740, phone number (301) 837-2903. ...

  14. Digital phonocardiographic experiments and signal processing in multidisciplinary fields of university education

    NASA Astrophysics Data System (ADS)

    Nagy, Tamás; Vadai, Gergely; Gingl, Zoltán

    2017-09-01

    Modern measurement of physical signals is based on the use of sensors, electronic signal conditioning, analog-to-digital conversion and digital signal processing carried out by dedicated software. The same signal chain is used in many devices such as home appliances, automotive electronics, medical instruments, and smartphones. Teaching the theoretical, experimental, and signal processing background must be an essential part of improving the standard of higher education, and it fits well to the increasingly multidisciplinary nature of physics and engineering too. In this paper, we show how digital phonocardiography can be used in university education as a universal, highly scalable, exciting, and inspiring laboratory practice and as a demonstration at various levels and complexity. We have developed open-source software templates in modern programming languages to support immediate use and to serve as a basis of further modifications using personal computers, tablets, and smartphones.

  15. BAO Plate Archive Project: Digitization, Electronic Database and Research Programmes

    NASA Astrophysics Data System (ADS)

    Mickaelian, A. M.; Abrahamyan, H. V.; Andreasyan, H. R.; Azatyan, N. M.; Farmanyan, S. V.; Gigoyan, K. S.; Gyulzadyan, M. V.; Khachatryan, K. G.; Knyazyan, A. V.; Kostandyan, G. R.; Mikayelyan, G. A.; Nikoghosyan, E. H.; Paronyan, G. M.; Vardanyan, A. V.

    2016-06-01

    The most important part of the astronomical observational heritage are astronomical plate archives created on the basis of numerous observations at many observatories. Byurakan Astrophysical Observatory (BAO) plate archive consists of 37,000 photographic plates and films, obtained at 2.6m telescope, 1m and 0.5m Schmidt type and other smaller telescopes during 1947-1991. In 2002-2005, the famous Markarian Survey (also called First Byurakan Survey, FBS) 1874 plates were digitized and the Digitized FBS (DFBS) was created. New science projects have been conducted based on these low-dispersion spectroscopic material. A large project on the whole BAO Plate Archive digitization, creation of electronic database and its scientific usage was started in 2015. A Science Program Board is created to evaluate the observing material, to investigate new possibilities and to propose new projects based on the combined usage of these observations together with other world databases. The Executing Team consists of 11 astronomers and 2 computer scientists and will use 2 EPSON Perfection V750 Pro scanners for the digitization, as well as Armenian Virtual Observatory (ArVO) database will be used to accommodate all new data. The project will run during 3 years in 2015-2017 and the final result will be an electronic database and online interactive sky map to be used for further research projects, mainly including high proper motion stars, variable objects and Solar System bodies.

  16. BAO Plate Archive digitization, creation of electronic database and its scientific usage

    NASA Astrophysics Data System (ADS)

    Mickaelian, Areg M.

    2015-08-01

    Astronomical plate archives created on the basis of numerous observations at many observatories are important part of the astronomical heritage. Byurakan Astrophysical Observatory (BAO) plate archive consists of 37,500 photographic plates and films, obtained at 2.6m telescope, 1m and 0.5m Schmidt telescopes and other smaller ones during 1947-1991. In 2002-2005, the famous Markarian Survey (First Byurakan Survey, FBS) 2000 plates were digitized and the Digitized FBS (DFBS, http://www.aras.am/Dfbs/dfbs.html) was created. New science projects have been conducted based on these low-dispersion spectroscopic material. In 2015, we have started a project on the whole BAO Plate Archive digitization, creation of electronic database and its scientific usage. A Science Program Board is created to evaluate the observing material, to investigate new possibilities and to propose new projects based on the combined usage of these observations together with other world databases. The Executing Team consists of 9 astronomers and 3 computer scientists and will use 2 EPSON Perfection V750 Pro scanners for the digitization, as well as Armenian Virtual Observatory (ArVO) database to accommodate all new data. The project will run during 3 years in 2015-2017 and the final result will be an electronic database and online interactive sky map to be used for further research projects.

  17. 76 FR 31992 - In the Matter of Nine Mile Point Nuclear Station, LLC; Nine Mile Point Nuclear Station...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-06-02

    ... Secretary by e-mail at [email protected] , or by telephone at 301-415-1677, to request (1) a digital...-issued digital ID certificate). Based upon this information, the Secretary will establish an electronic... docket. Information about applying for a digital ID certificate is available on the NRC's public Web site...

  18. 76 FR 20722 - In the Matter of Indiana Michigan Power Company; DC Cook Nuclear Plant Independent Spent Fuel...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-04-13

    ... Secretary by e-mail at [email protected] , or by telephone at 301-415-1677, to request (1) a digital...-issued digital ID certificate). Based upon this information, the Secretary will establish an electronic... docket. Information about applying for a digital ID certificate is available on NRC's public Web site at...

  19. Another Look at Plagiarism in the Digital Age: Is It Time to Turn in My Badge?

    ERIC Educational Resources Information Center

    Colvin, Benie B.

    2007-01-01

    In this article, the author talks about plagiarism in the digital age and how plagiarism challenges teachers in their relationship with students. With a growing body of digital commentary and the looming dominance of electronic writing, current professional consensus in the plagiarism dilemma appears dubious and the slope gets more slippery every…

  20. Creating Collaboration: Exploring the Development of a Baptist Digital Library and Archive. A Case Study

    ERIC Educational Resources Information Center

    Hall, Taffey

    2013-01-01

    The purpose of this study was to explore the construction of a collaborative Baptist digital library and archive on the Internet. The study investigated how a central electronic location of digitized Baptist primary source materials could look and work on the Internet and how such a project could benefit Baptist history professors, the primary…

Top