Sample records for digital test objects

  1. 42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...

  2. 42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... image acquisition, digitization, processing, compression, transmission, display, archiving, and... quality digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object... digital radiographic image files from six or more sample chest radiographs that are of acceptable quality...

  3. COMPLEX CONDITIONAL CONTROL BY PIGEONS IN A CONTINUOUS VIRTUAL ENVIRONMENT

    PubMed Central

    Qadri, Muhammad A. J.; Reid, Sean; Cook, Robert G.

    2016-01-01

    We tested two pigeons in a continuously streaming digital environment. Using animation software that constantly presented a dynamic, three-dimensional (3D) environment, the animals were tested with a conditional object identification task. The correct object at a given time depended on the virtual context currently streaming in front of the pigeon. Pigeons were required to accurately peck correct target objects in the environment for food reward, while suppressing any pecks to intermixed distractor objects which delayed the next object’s presentation. Experiment 1 established that the pigeons’ discrimination of two objects could be controlled by the surface material of the digital terrain. Experiment 2 established that the pigeons’ discrimination of four objects could be conjunctively controlled by both the surface material and topography of the streaming environment. These experiments indicate that pigeons can simultaneously process and use at least two context cues from a streaming environment to control their identification behavior of passing objects. These results add to the promise of testing interactive digital environments with animals to advance our understanding of cognition and behavior. PMID:26781058

  4. F-8C digital CCV flight control laws

    NASA Technical Reports Server (NTRS)

    Hartmann, G. L.; Hauge, J. A.; Hendrick, R. C.

    1976-01-01

    A set of digital flight control laws were designed for the NASA F-8C digital fly-by-wire aircraft. The control laws emphasize Control Configured Vehicle (CCV) benefits. Specific pitch axis objectives were improved handling qualities, angle-of-attack limiting, gust alleviation, drag reduction in steady and maneuvering flight, and a capability to fly with reduced static stability. The lateral-directional design objectives were improved Dutch roll damping and turn coordination over a wide range in angle-of-attack. An overall program objective was to explore the use of modern control design methodilogy to achieve these specific CCV benefits. Tests for verifying system integrity, an experimental design for handling qualities evaluation, and recommended flight test investigations were specified.

  5. Digital implementation of a neural network for imaging

    NASA Astrophysics Data System (ADS)

    Wood, Richard; McGlashan, Alex; Yatulis, Jay; Mascher, Peter; Bruce, Ian

    2012-10-01

    This paper outlines the design and testing of a digital imaging system that utilizes an artificial neural network with unsupervised and supervised learning to convert streaming input (real time) image space into parameter space. The primary objective of this work is to investigate the effectiveness of using a neural network to significantly reduce the information density of streaming images so that objects can be readily identified by a limited set of primary parameters and act as an enhanced human machine interface (HMI). Many applications are envisioned including use in biomedical imaging, anomaly detection and as an assistive device for the visually impaired. A digital circuit was designed and tested using a Field Programmable Gate Array (FPGA) and an off the shelf digital camera. Our results indicate that the networks can be readily trained when subject to limited sets of objects such as the alphabet. We can also separate limited object sets with rotational and positional invariance. The results also show that limited visual fields form with only local connectivity.

  6. Development of a Digital-Based Instrument to Assess Perceived Motor Competence in Children: Face Validity, Test-Retest Reliability, and Internal Consistency

    PubMed Central

    Palmer, Kara K.

    2017-01-01

    Assessing children’s perceptions of their movement abilities (i.e., perceived competence) is traditionally done using picture scales—Pictorial Scale of Perceived Competence and Acceptance for Young Children or Pictorial Scale of Perceived Movement Skill Competence. Pictures fail to capture the temporal components of movement. To address this limitation, we created a digital-based instrument to assess perceived motor competence: the Digital Scale of Perceived Motor Competence. The purpose of this study was to determine the validity, reliability, and internal consistency of the Digital-based Scale of Perceived Motor Skill Competence. The Digital-based Scale of Perceived Motor Skill Competence is based on the twelve fundamental motor skills from the Test of Gross Motor Development-2nd Edition with a similar layout and item structure as the Pictorial Scale of Perceived Movement Skill Competence. Face Validity of the instrument was examined in Phase I (n = 56; Mage = 8.6 ± 0.7 years, 26 girls). Test-retest reliability and internal consistency were assessed in Phase II (n = 54, Mage = 8.7 years ± 0.5 years, 26 girls). Intra-class correlations (ICC) and Cronbach’s alpha were conducted to determine test-retest reliability and internal consistency for all twelve skills along with locomotor and object control subscales. The Digital Scale of Perceived Motor Competence demonstrates excellent test-retest reliability (ICC = 0.83, total; ICC = 0.77, locomotor; ICC = 0.79, object control) and acceptable/good internal consistency (α = 0.62, total; α = 0.57, locomotor; α = 0.49, object control). Findings provide evidence of the reliability of the three level digital-based instrument of perceived motor competence for older children. PMID:29910408

  7. 42 CFR 37.44 - Approval of radiographic facilities that use digital radiography systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... effective management, safety, and proper performance of chest image acquisition, digitization, processing... digital chest radiographs by submitting to NIOSH digital radiographic image files of a test object (e.g... radiographic image files from six or more sample chest radiographs that are of acceptable quality to one or...

  8. Accuracy, repeatability, and reproducibility of Artemis very high-frequency digital ultrasound arc-scan lateral dimension measurements

    PubMed Central

    Reinstein, Dan Z.; Archer, Timothy J.; Silverman, Ronald H.; Coleman, D. Jackson

    2008-01-01

    Purpose To determine the accuracy, repeatability, and reproducibility of measurement of lateral dimensions using the Artemis (Ultralink LLC) very high-frequency (VHF) digital ultrasound (US) arc scanner. Setting London Vision Clinic, London, United Kingdom. Methods A test object was measured first with a micrometer and then with the Artemis arc scanner. Five sets of 10 consecutive B-scans of the test object were performed with the scanner. The test object was removed from the system between each scan set. One expert observer and one newly trained observer separately measured the lateral dimension of the test object. Two-factor analysis of variance was performed. The accuracy was calculated as the average bias of the scan set averages. The repeatability and reproducibility coefficients were calculated. The coefficient of variation (CV) was calculated for repeatability and reproducibility. Results The test object was measured to be 10.80 mm wide. The mean lateral dimension bias was 0.00 mm. The repeatability coefficient was 0.114 mm. The reproducibility coefficient was 0.026 mm. The repeatability CV was 0.38%, and the reproducibility CV was 0.09%. There was no statistically significant variation between observers (P = .0965). There was a statistically significant variation between scan sets (P = .0036) attributed to minor vertical changes in the alignment of the test object between consecutive scan sets. Conclusion The Artemis VHF digital US arc scanner obtained accurate, repeatable, and reproducible measurements of lateral dimensions of the size commonly found in the anterior segment. PMID:17081860

  9. Automatic Topography Using High Precision Digital Moire Methods

    NASA Astrophysics Data System (ADS)

    Yatagai, T.; Idesawa, M.; Saito, S.

    1983-07-01

    Three types of moire topographic methods using digital techniques are proposed. Deformed gratings obtained by projecting a reference grating onto an object under test are subjected to digital analysis. The electronic analysis procedures of deformed gratings described here enable us to distinguish between depression and elevation of the object, so that automatic measurement of 3-D shapes and automatic moire fringe interpolation are performed. Based on the digital moire methods, we have developed a practical measurement system, with a linear photodiode array on a micro-stage as a scanning image sensor. Examples of fringe analysis in medical applications are presented.

  10. System for objective assessment of image differences in digital cinema

    NASA Astrophysics Data System (ADS)

    Fliegel, Karel; Krasula, Lukáš; Páta, Petr; Myslík, Jiří; Pecák, Josef; Jícha, Marek

    2014-09-01

    There is high demand for quick digitization and subsequent image restoration of archived film records. Digitization is very urgent in many cases because various invaluable pieces of cultural heritage are stored on aging media. Only selected records can be reconstructed perfectly using painstaking manual or semi-automatic procedures. This paper aims to answer the question what are the quality requirements on the restoration process in order to obtain acceptably close visual perception of the digitally restored film in comparison to the original analog film copy. This knowledge is very important to preserve the original artistic intention of the movie producers. Subjective experiment with artificially distorted images has been conducted in order to answer the question what is the visual impact of common image distortions in digital cinema. Typical color and contrast distortions were introduced and test images were presented to viewers using digital projector. Based on the outcome of this subjective evaluation a system for objective assessment of image distortions has been developed and its performance tested. The system utilizes calibrated digital single-lens reflex camera and subsequent analysis of suitable features of images captured from the projection screen. The evaluation of captured image data has been optimized in order to obtain predicted differences between the reference and distorted images while achieving high correlation with the results of subjective assessment. The system can be used to objectively determine the difference between analog film and digital cinema images on the projection screen.

  11. Recurrent Convolutional Neural Networks: A Better Model of Biological Object Recognition.

    PubMed

    Spoerer, Courtney J; McClure, Patrick; Kriegeskorte, Nikolaus

    2017-01-01

    Feedforward neural networks provide the dominant model of how the brain performs visual object recognition. However, these networks lack the lateral and feedback connections, and the resulting recurrent neuronal dynamics, of the ventral visual pathway in the human and non-human primate brain. Here we investigate recurrent convolutional neural networks with bottom-up (B), lateral (L), and top-down (T) connections. Combining these types of connections yields four architectures (B, BT, BL, and BLT), which we systematically test and compare. We hypothesized that recurrent dynamics might improve recognition performance in the challenging scenario of partial occlusion. We introduce two novel occluded object recognition tasks to test the efficacy of the models, digit clutter (where multiple target digits occlude one another) and digit debris (where target digits are occluded by digit fragments). We find that recurrent neural networks outperform feedforward control models (approximately matched in parametric complexity) at recognizing objects, both in the absence of occlusion and in all occlusion conditions. Recurrent networks were also found to be more robust to the inclusion of additive Gaussian noise. Recurrent neural networks are better in two respects: (1) they are more neurobiologically realistic than their feedforward counterparts; (2) they are better in terms of their ability to recognize objects, especially under challenging conditions. This work shows that computer vision can benefit from using recurrent convolutional architectures and suggests that the ubiquitous recurrent connections in biological brains are essential for task performance.

  12. D Imaging for Museum Artefacts: a Portable Test Object for Heritage and Museum Documentation of Small Objects

    NASA Astrophysics Data System (ADS)

    Hess, M.; Robson, S.

    2012-07-01

    3D colour image data generated for the recording of small museum objects and archaeological finds are highly variable in quality and fitness for purpose. Whilst current technology is capable of extremely high quality outputs, there are currently no common standards or applicable guidelines in either the museum or engineering domain suited to scientific evaluation, understanding and tendering for 3D colour digital data. This paper firstly explains the rationale towards and requirements for 3D digital documentation in museums. Secondly it describes the design process, development and use of a new portable test object suited to sensor evaluation and the provision of user acceptance metrics. The test object is specifically designed for museums and heritage institutions and includes known surface and geometric properties which support quantitative and comparative imaging on different systems. The development for a supporting protocol will allow object reference data to be included in the data processing workflow with specific reference to conservation and curation.

  13. Development and validation of a smartphone-based digits-in-noise hearing test in South African English.

    PubMed

    Potgieter, Jenni-Marí; Swanepoel, De Wet; Myburgh, Hermanus Carel; Hopper, Thomas Christopher; Smits, Cas

    2015-07-01

    The objective of this study was to develop and validate a smartphone-based digits-in-noise hearing test for South African English. Single digits (0-9) were recorded and spoken by a first language English female speaker. Level corrections were applied to create a set of homogeneous digits with steep speech recognition functions. A smartphone application was created to utilize 120 digit-triplets in noise as test material. An adaptive test procedure determined the speech reception threshold (SRT). Experiments were performed to determine headphones effects on the SRT and to establish normative data. Participants consisted of 40 normal-hearing subjects with thresholds ≤15 dB across the frequency spectrum (250-8000 Hz) and 186 subjects with normal-hearing in both ears, or normal-hearing in the better ear. The results show steep speech recognition functions with a slope of 20%/dB for digit-triplets presented in noise using the smartphone application. The results of five headphone types indicate that the smartphone-based hearing test is reliable and can be conducted using standard Android smartphone headphones or clinical headphones. A digits-in-noise hearing test was developed and validated for South Africa. The mean SRT and speech recognition functions correspond to previous developed telephone-based digits-in-noise tests.

  14. Digital electronic engine control F-15 overview

    NASA Technical Reports Server (NTRS)

    Kock, B.

    1984-01-01

    A flight test evaluation of the digital elctronic engine control (DEEC) system was conducted. An overview of the flight program is presented. The roles of the participating parties, the system, and the flight program objectives are described. The test program approach is discussed, and the engine performance benefits are summarized. A description of the follow-on programs is included.

  15. Digital Controller For Acoustic Levitation

    NASA Technical Reports Server (NTRS)

    Tarver, D. Kent

    1989-01-01

    Acoustic driver digitally controls sound fields along three axes. Allows computerized acoustic levitation and manipulation of small objects for such purposes as containerless processing and nuclear-fusion power experiments. Also used for controlling motion of vibration-testing tables in three dimensions.

  16. VLBI Digital-Backend Intercomparison Test Report

    NASA Technical Reports Server (NTRS)

    Whitney, Alan; Beaudoin, Christopher; Cappallo, Roger; Niell, Arthur; Petrachenko, Bill; Ruszczyk, Chester A.; Titus, Mike

    2013-01-01

    Issues related to digital-backend (DBE) systems can be difficult to evaluate in either local tests or actual VLBI experiments. The 2nd DBE intercomparison workshop at Haystack Observatory on 25-26 October 2012 provided a forum to explicitly address validation and interoperability issues among independent global developers of DBE equipment. This special report discusses the workshop. It identifies DBE systems that were tested at the workshop, describes the test objectives and procedures, and reports and discusses the results of the testing.

  17. Production tolerance of additive manufactured polymeric objects for clinical applications.

    PubMed

    Braian, Michael; Jimbo, Ryo; Wennerberg, Ann

    2016-07-01

    To determine the production tolerance of four commercially available additive manufacturing systems. By reverse engineering annex A and B from the ISO_12836;2012, two geometrical figures relevant to dentistry was obtained. Object A specifies the measurement of an inlay-shaped object and B a multi-unit specimen to simulate a four-unit bridge model. The objects were divided into x, y and z measurements, object A was divided into a total of 16 parameters and object B was tested for 12 parameters. The objects were designed digitally and manufactured by professionals in four different additive manufacturing systems; each system produced 10 samples of each objects. For object A, three manufacturers presented an accuracy of <100μm and one system showed an accuracy of <20μm. For object B, all systems presented an accuracy of <100μm, and most parameters were <40μm. The standard deviation for most parameters were <40μm. The growing interest and use of intra-oral digitizing systems stresses the use of computer aided manufacturing of working models. The additive manufacturing techniques has the potential to help us in the digital workflow. Thus, it is important to have knowledge about production accuracy and tolerances. This study presents a method to test additive manufacturing units for accuracy and repeatability. Copyright © 2016 The Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  18. Characterization of fluid flow by digital correlation of scattered light

    NASA Technical Reports Server (NTRS)

    Gilbert, John A.; Matthys, Donald R.

    1989-01-01

    The objective is to produce a physical system suitable for a space environment that can measure fluid velocities in a three-dimensional volume by the development of a particle correlation velocimetry technique. Experimental studies were conducted on a field test cell to demonstrate the suitability and accuracy of digital correlation techniques for measuring two-dimensional fluid flows. This objective was satisfied by: (1) the design of an appropriate illumination and detection system for making velocity measurements within a test cell; (2) the design and construction of a test cell; (3) the preliminary evaluations on fluid and seeding requirements; and (4) the performance of controlled tests using a multiple exposure correlation technique. This presentation is represented by viewgraphs with very little text.

  19. The Objective and Subjective Evaluation of Multichannel Expansion in Wide Dynamic Range Compression Hearing Instruments

    ERIC Educational Resources Information Center

    Plyler, Patrick N.; Lowery, Kristy J.; Hamby, Hilary M.; Trine, Timothy D.

    2007-01-01

    Purpose: The effects of multichannel expansion on the objective and subjective evaluation of 20 listeners fitted binaurally with 4-channel, digital in-the-ear hearing instruments were investigated. Method: Objective evaluations were conducted in quiet using the Connected Speech Test (CST) and in noise using the Hearing in Noise Test (HINT) at 40,…

  20. Learned Manipulation at Unconstrained Contacts Does Not Transfer across Hands

    PubMed Central

    Fu, Qiushi; Choi, Jason Y.; Gordon, Andrew M.; Jesunathadas, Mark; Santello, Marco

    2014-01-01

    Recent studies about sensorimotor control of the human hand have focused on how dexterous manipulation is learned and generalized. Here we address this question by testing the extent to which learned manipulation can be transferred when the contralateral hand is used and/or object orientation is reversed. We asked subjects to use a precision grip to lift a grip device with an asymmetrical mass distribution while minimizing object roll during lifting by generating a compensatory torque. Subjects were allowed to grasp anywhere on the object’s vertical surfaces, and were therefore able to modulate both digit positions and forces. After every block of eight trials performed in one manipulation context (i.e., using the right hand and at a given object orientation), subjects had to lift the same object in the second context for one trial (transfer trial). Context changes were made by asking subjects to switch the hand used to lift the object and/or rotate the object 180° about a vertical axis. Therefore, three transfer conditions, hand switch (HS), object rotation (OR), and both hand switch and object rotation (HS+OR), were tested and compared with hand matched control groups who did not experience context changes. We found that subjects in all transfer conditions adapted digit positions across multiple transfer trials similar to the learning of control groups, regardless of different changes of contexts. Moreover, subjects in both HS and HS+OR group also adapted digit forces similar to the control group, suggesting independent learning of the left hand. In contrast, the OR group showed significant negative transfer of the compensatory torque due to an inability to adapt digit forces. Our results indicate that internal representations of dexterous manipulation tasks may be primarily built through the hand used for learning and cannot be transferred across hands. PMID:25233091

  1. Application of comparative digital holography for distant shape control

    NASA Astrophysics Data System (ADS)

    Baumbach, Torsten; Osten, Wolfgang; von Kopylow, Christoph; Juptner, Werner P. O.

    2004-09-01

    The comparison of two objects is of great importance in the industrial production process. Especially comparing the shape is of particular interest for maintaining calibration tools or controlling the tolerance in the deviation between a sample and a master. Outsourcing and globalization of production places can result in large distances between co-operating partners and might cause problems for maintaining quality standards. Consequently new challenges arise for optical measurement techniques especially in the field of industrial shape control. In this paper we describe the progress of implementing a novel technique for comparing directly two objects with different microstructure. The technique is based on the combination of comparative holography and digital holography. Comparing the objects can be done in two ways. One is the digital comparison in the computer and the other way is by using the analogue reconstruction of a master hologram with a spatial light modulator (SLM) as coherent mask for illuminating the test object. Since this mask is stored digitally it can be transmitted via telecommunication networks and this enables the access to the full optical information of the master object at any place wanted. Beside the basic principle of comparative digital holography (CDH), we will show in this paper the set-up for doing the analogue comparison of two objects with increased sensitivity in comparison to former measurements and the calibration of the SLM that is used for the experiments. We will give examples for the digital and the analogue comparison of objects including a verification of our results by another optical measurement technique.

  2. Technical and investigative support for high density digital satellite recording systems

    NASA Technical Reports Server (NTRS)

    Schultz, R. A.

    1982-01-01

    Methods and results of examinations and tests conducted on magnetic recording tapes under consideration for a high density digital (HDDR) satellite recording system are described. The examinations and tests investigate the performance of tapes with respect to their physical, magnetic and electrical characteristics. The objective of the tests, the likely significance of typical results, and the importance of the characteristics under investigation to the application are included. Theoretical discussions of measurement methods are provided where appropriate. Methods and results are discussed; the results of some sections are tabulated together to facilitate their comparison. The conclusion of each test section relates the test results to their possible significance and attempts to correlate the results of that section with the results of other tests. Some of the sections analyze sources of error inherent in the measurement methods or relate the value of the information obtained to the objectives of the test or the overall purpose of the project.

  3. Description and Flight Test Results of the NASA F-8 Digital Fly-by-Wire Control System

    NASA Technical Reports Server (NTRS)

    1975-01-01

    A NASA program to develop digital fly-by-wire (DFBW) technology for aircraft applications is discussed. Phase I of the program demonstrated the feasibility of using a digital fly-by-wire system for aircraft control through developing and flight testing a single channel system, which used Apollo hardware, in an F-8C airplane. The objective of Phase II of the program is to establish a technology base for designing practical DFBW systems. It will involve developing and flight testing a triplex digital fly-by-wire system using state-of-the-art airborne computers, system hardware, software, and redundancy concepts. The papers included in this report describe the Phase I system and its development and present results from the flight program. Man-rated flight software and the effects of lightning on digital flight control systems are also discussed.

  4. Flight evaluation of a digital electronic engine control system in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Myers, L. P.; Mackall, K. G.; Burcham, F. W., Jr.; Walter, W. A.

    1982-01-01

    Benefits provided by a full-authority digital engine control are related to improvements in engine efficiency, performance, and operations. An additional benefit is the capability of detecting and accommodating failures in real time and providing engine-health diagnostics. The digital electronic engine control (DEEC), is a full-authority digital engine control developed for the F100-PW-100 turbofan engine. The DEEC has been flight tested on an F-15 aircraft. The flight tests had the objective to evaluate the DEEC hardware and software over the F-15 flight envelope. A description is presented of the results of the flight tests, which consisted of nonaugmented and augmented throttle transients, airstarts, and backup control operations. The aircraft, engine, DEEC system, and data acquisition and reduction system are discussed.

  5. Effect of educational status on performance of older adults in digital cognitive tasks: A systematic review

    PubMed Central

    de Carvalho, Lucas Pelegrini Nogueira; Monteiro, Diana Quirino; Orlandi, Fabiana de Souza; Zazzetta, Marisa Silvana; Pavarini, Sofia Cristina Iost

    2017-01-01

    As people age, cognitive abilities may decline resulting in serious disabilities. Neuropsychological instruments can provide information on the cognitive state of older adults. Researchers worldwide have been using digital cognitive tests to assess cognitive domains. Objective To determine whether educational status affects the performance of older adults on digital cognitive tasks. Methods A systematic review of articles in English, Portuguese, or Spanish published in the last 5 years was conducted. The databases searched were SCOPUS, PubMed, Lilacs, Scielo and PsychInfo. The PRISMA method was used. Results A total of 7,089 articles were initially retrieved. After search and exclusion with justification, seven articles were selected for further review. Conclusion The findings revealed that researchers using digital tasks generally employed paper-based tests to compare results. Also, no association between years of education and test performance was found. Finally, a dearth of studies using digital tests published by Brazilian researchers was evident. PMID:29213502

  6. Digital servo control of random sound test excitation. [in reverberant acoustic chamber

    NASA Technical Reports Server (NTRS)

    Nakich, R. B. (Inventor)

    1974-01-01

    A digital servocontrol system for random noise excitation of a test object in a reverberant acoustic chamber employs a plurality of sensors spaced in the sound field to produce signals in separate channels which are decorrelated and averaged. The average signal is divided into a plurality of adjacent frequency bands cyclically sampled by a time division multiplex system, converted into digital form, and compared to a predetermined spectrum value stored in digital form. The results of the comparisons are used to control a time-shared up-down counter to develop gain control signals for the respective frequency bands in the spectrum of random sound energy picked up by the microphones.

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, Darren M.

    Sandia National Laboratories has tested and evaluated Geotech Smart24 data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Geotech Smart24 digitizer with a Fortezza PCMCIA cryptomore » card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy, analog bandwidth and calibrator performance.« less

  8. Digital Invasions: from Point Clouds to Historical Building Object Modeling H-Bom of a Unesco Whl Site

    NASA Astrophysics Data System (ADS)

    Chiabrando, F.; Lo Turco, M.; Santagati, C.

    2017-02-01

    The paper here presented shows the outcomes of a research/didactic activity carried out within a workshop titled "Digital Invasions. From point cloud to Heritage Building Information Modeling" held at Politecnico di Torino (29th September-5th October 2016). The term digital invasions refers to an Italian bottom up project born in the 2013 with the aim of promoting innovative digital ways for the enhancement of Cultural Heritage by the co-creation of cultural contents and its sharing through social media platforms. At this regard, we have worked with students of Architectural Master of Science degree, training them with a multidisciplinary teaching team (Architectural Representation, History of Architecture, Restoration, Digital Communication and Geomatics). The aim was also to test if our students could be involved in a sort of niche crowdsourcing for the creation of a library of H-BOMS (Historical-Building Object Modeling) of architectural elements.

  9. Disseminating relevant health information to underserved audiences: implications of the Digital Divide Pilot Projects*

    PubMed Central

    Kreps, Gary L.

    2005-01-01

    Objective: This paper examines the influence of the digital divide on disparities in health outcomes for vulnerable populations, identifying implications for medical and public libraries. Method: The paper describes the results of the Digital Divide Pilot Projects demonstration research programs funded by the National Cancer Institute to test new strategies for disseminating relevant health information to underserved and at-risk audiences. Results: The Digital Divide Pilot Projects field-tested innovative systemic strategies for helping underserved populations access and utilize relevant health information to make informed health-related decisions about seeking appropriate health care and support, resisting avoidable and significant health risks, and promoting their own health. Implications: The paper builds on the Digital Divide Pilot Projects by identifying implications for developing health communication strategies that libraries can adopt to provide digital health information to vulnerable populations. PMID:16239960

  10. Radiation dose reduction in the evaluation of scoliosis: an application of digital radiography

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kushner, D.C.; Cleveland, R.H.; Herman, T.E.

    1986-10-01

    This report documents the clinical testing of scanning beam digital radiography as an imaging method in patients with scoliosis. This type of digital imaging requires a skin exposure of only 2.4 mR (0.619 microC/kg) per image, compared with the lowest possible posteroanterior screen-film exposure of 10 mR (2.58 microC/kg) at the chest and 60 mR (15.48 microC/kg) at the lumbar spine. Digital radiographic and screen-film images were obtained on multiple test objects and 273 patients. Scoliosis measurements using screen-film radiographs and digital radiographs were comparable to within a mean difference of 1 degrees at many different degrees of severity. Themore » low-dose digital images were found to be useful and accurate for the detection and measurement of scoliosis after the first screen-film radiographs have excluded tumors and structural abnormalities.« less

  11. 3D Surface Reconstruction for Lower Limb Prosthetic Model using Radon Transform

    NASA Astrophysics Data System (ADS)

    Sobani, S. S. Mohd; Mahmood, N. H.; Zakaria, N. A.; Razak, M. A. Abdul

    2018-03-01

    This paper describes the idea to realize three-dimensional surfaces of objects with cylinder-based shapes where the techniques adopted and the strategy developed for a non-rigid three-dimensional surface reconstruction of an object from uncalibrated two-dimensional image sequences using multiple-view digital camera and turntable setup. The surface of an object is reconstructed based on the concept of tomography with the aid of performing several digital image processing algorithms on the two-dimensional images captured by a digital camera in thirty-six different projections and the three-dimensional structure of the surface is analysed. Four different objects are used as experimental models in the reconstructions and each object is placed on a manually rotated turntable. The results shown that the proposed method has successfully reconstruct the three-dimensional surface of the objects and practicable. The shape and size of the reconstructed three-dimensional objects are recognizable and distinguishable. The reconstructions of objects involved in the test are strengthened with the analysis where the maximum percent error obtained from the computation is approximately 1.4 % for the height whilst 4.0%, 4.79% and 4.7% for the diameters at three specific heights of the objects.

  12. Identifying images of handwritten digits using deep learning in H2O

    NASA Astrophysics Data System (ADS)

    Sadhasivam, Jayakumar; Charanya, R.; Kumar, S. Harish; Srinivasan, A.

    2017-11-01

    Automatic digit recognition is of popular interest today. Deep learning techniques make it possible for object recognition in image data. Perceiving the digit has turned into a fundamental part as far as certifiable applications. Since, digits are composed in various styles in this way to distinguish the digit it is important to perceive and arrange it with the assistance of machine learning methods. This exploration depends on supervised learning vector quantization neural system arranged under counterfeit artificial neural network. The pictures of digits are perceived, prepared and tried. After the system is made digits are prepared utilizing preparing dataset vectors and testing is connected to the pictures of digits which are separated to each other by fragmenting the picture and resizing the digit picture as needs be for better precision.

  13. Wide field of view common-path lateral-shearing digital holographic interference microscope

    NASA Astrophysics Data System (ADS)

    Vora, Priyanka; Trivedi, Vismay; Mahajan, Swapnil; Patel, Nimit; Joglekar, Mugdha; Chhaniwal, Vani; Moradi, Ali-Reza; Javidi, Bahram; Anand, Arun

    2017-12-01

    Quantitative three-dimensional (3-D) imaging of living cells provides important information about the cell morphology and its time variation. Off-axis, digital holographic interference microscopy is an ideal tool for 3-D imaging, parameter extraction, and classification of living cells. Two-beam digital holographic microscopes, which are usually employed, provide high-quality 3-D images of micro-objects, albeit with lower temporal stability. Common-path digital holographic geometries, in which the reference beam is derived from the object beam, provide higher temporal stability along with high-quality 3-D images. Self-referencing geometry is the simplest of the common-path techniques, in which a portion of the object beam itself acts as the reference, leading to compact setups using fewer optical elements. However, it has reduced field of view, and the reference may contain object information. Here, we describe the development of a common-path digital holographic microscope, employing a shearing plate and converting one of the beams into a separate reference by employing a pin-hole. The setup is as compact as self-referencing geometry, while providing field of view as wide as that of a two-beam microscope. The microscope is tested by imaging and quantifying the morphology and dynamics of human erythrocytes.

  14. Wide field of view common-path lateral-shearing digital holographic interference microscope.

    PubMed

    Vora, Priyanka; Trivedi, Vismay; Mahajan, Swapnil; Patel, Nimit; Joglekar, Mugdha; Chhaniwal, Vani; Moradi, Ali-Reza; Javidi, Bahram; Anand, Arun

    2017-12-01

    Quantitative three-dimensional (3-D) imaging of living cells provides important information about the cell morphology and its time variation. Off-axis, digital holographic interference microscopy is an ideal tool for 3-D imaging, parameter extraction, and classification of living cells. Two-beam digital holographic microscopes, which are usually employed, provide high-quality 3-D images of micro-objects, albeit with lower temporal stability. Common-path digital holographic geometries, in which the reference beam is derived from the object beam, provide higher temporal stability along with high-quality 3-D images. Self-referencing geometry is the simplest of the common-path techniques, in which a portion of the object beam itself acts as the reference, leading to compact setups using fewer optical elements. However, it has reduced field of view, and the reference may contain object information. Here, we describe the development of a common-path digital holographic microscope, employing a shearing plate and converting one of the beams into a separate reference by employing a pin-hole. The setup is as compact as self-referencing geometry, while providing field of view as wide as that of a two-beam microscope. The microscope is tested by imaging and quantifying the morphology and dynamics of human erythrocytes. (2017) COPYRIGHT Society of Photo-Optical Instrumentation Engineers (SPIE).

  15. Securing Digital Images Integrity using Artificial Neural Networks

    NASA Astrophysics Data System (ADS)

    Hajji, Tarik; Itahriouan, Zakaria; Ouazzani Jamil, Mohammed

    2018-05-01

    Digital image signature is a technique used to protect the image integrity. The application of this technique can serve several areas of imaging applied to smart cities. The objective of this work is to propose two methods to protect digital image integrity. We present a description of two approaches using artificial neural networks (ANN) to digitally sign an image. The first one is “Direct Signature without learning” and the second is “Direct Signature with learning”. This paper presents the theory of proposed approaches and an experimental study to test their effectiveness.

  16. Object-oriented classification of drumlins from digital elevation models

    NASA Astrophysics Data System (ADS)

    Saha, Kakoli

    Drumlins are common elements of glaciated landscapes which are easily identified by their distinct morphometric characteristics including shape, length/width ratio, elongation ratio, and uniform direction. To date, most researchers have mapped drumlins by tracing contours on maps, or through on-screen digitization directly on top of hillshaded digital elevation models (DEMs). This paper seeks to utilize the unique morphometric characteristics of drumlins and investigates automated extraction of the landforms as objects from DEMs by Definiens Developer software (V.7), using the 30 m United States Geological Survey National Elevation Dataset DEM as input. The Chautauqua drumlin field in Pennsylvania and upstate New York, USA was chosen as a study area. As the study area is huge (approximately covers 2500 sq.km. of area), small test areas were selected for initial testing of the method. Individual polygons representing the drumlins were extracted from the elevation data set by automated recognition, using Definiens' Multiresolution Segmentation tool, followed by rule-based classification. Subsequently parameters such as length, width and length-width ratio, perimeter and area were measured automatically. To test the accuracy of the method, a second base map was produced by manual on-screen digitization of drumlins from topographic maps and the same morphometric parameters were extracted from the mapped landforms using Definiens Developer. Statistical comparison showed a high agreement between the two methods confirming that object-oriented classification for extraction of drumlins can be used for mapping these landforms. The proposed method represents an attempt to solve the problem by providing a generalized rule-set for mass extraction of drumlins. To check that the automated extraction process was next applied to a larger area. Results showed that the proposed method is as successful for the bigger area as it was for the smaller test areas.

  17. Testing the Digital Divide: Does Access to High-Quality Use of Technology in Schools Affect Student Achievement?

    ERIC Educational Resources Information Center

    Talley, Gregory Keith

    2012-01-01

    This study investigates the relationship between access, use of technology and student achievement in public middle schools in Maryland. The objective of this study was to determine whether a digital divide (differences in access and utilization of technology based on student characteristics of race, socioeconomic status, and gender) exists among…

  18. Pinocchio testing in the forensic analysis of waiting lists: using public waiting list data from Finland and Spain for testing Newcomb-Benford’s Law

    PubMed Central

    López-Valcárcel, Beatriz G; González-Martel, Christian; Peiro, Salvador

    2018-01-01

    Objective Newcomb-Benford’s Law (NBL) proposes a regular distribution for first digits, second digits and digit combinations applicable to many different naturally occurring sources of data. Testing deviations from NBL is used in many datasets as a screening tool for identifying data trustworthiness problems. This study aims to compare public available waiting lists (WL) data from Finland and Spain for testing NBL as an instrument to flag up potential manipulation in WLs. Design Analysis of the frequency of Finnish and Spanish WLs first digits to determine if their distribution is similar to the pattern documented by NBL. Deviations from the expected first digit frequency were analysed using Pearson’s χ2, mean absolute deviation and Kuiper tests. Setting/participants Publicly available WL data from Finland and Spain, two countries with universal health insurance and National Health Systems but characterised by different levels of transparency and good governance standards. Main outcome measures Adjustment of the observed distribution of the numbers reported in Finnish and Spanish WL data to the expected distribution according to NBL. Results WL data reported by the Finnish health system fits first digit NBL according to all statistical tests used (p=0.6519 in χ2 test). For Spanish data, this hypothesis was rejected in all tests (p<0.0001 in χ2 test). Conclusions Testing deviations from NBL distribution can be a useful tool to identify problems with WL data trustworthiness and signalling the need for further testing. PMID:29743333

  19. Multi-axis transient vibration testing of space objects: Test philosophy, test facility, and control strategy

    NASA Technical Reports Server (NTRS)

    Lachenmayr, Georg

    1992-01-01

    IABG has been using various servohydraulic test facilities for many years for the reproduction of service loads and environmental loads on all kinds of test objects. For more than 15 years, a multi-axis vibration test facility has been under service, originally designed for earthquake simulation but being upgraded to the demands of space testing. First tests with the DFS/STM showed good reproduction accuracy and demonstrated the feasibility of transient vibration testing of space objects on a multi-axis hydraulic shaker. An approach to structural qualification is possible by using this test philosophy. It will be outlined and its obvious advantages over the state-of-the-art single-axis test will be demonstrated by example results. The new test technique has some special requirements to the test facility exceeding those of earthquake testing. Most important is the high reproduction accuracy demanded for a sophisticated control system. The state-of-the-art approach of analog closed-loop control circuits for each actuator combined with a static decoupling network and an off-line iterative waveform control is not able to meet all the demands. Therefore, the future over-all control system is implemented as hierarchical full digital closed-loop system on a highly parallel transputer network. The innermost layer is the digital actuator controller, the second one is the MDOF-control of the table movement. The outermost layer would be the off-line iterative waveform control, which is dedicated only to deal with the interaction of test table and test object or non-linear effects. The outline of the system will be presented.

  20. Application of digital control techniques for satellite medium power DC-DC converters

    NASA Astrophysics Data System (ADS)

    Skup, Konrad R.; Grudzinski, Pawel; Nowosielski, Witold; Orleanski, Piotr; Wawrzaszek, Roman

    2010-09-01

    The objective of this paper is to present a work concerning a digital control loop system for satellite medium power DC-DC converters that is done in Space Research Centre. The whole control process of a described power converter bases on a high speed digital signal processing. The paper presents a development of a FPGA digital controller for voltage mode stabilization that was implemented using VHDL. The described controllers are a classical digital PID controller and a bang-bang controller. The used converter for testing is a simple model of 5-20 W, 200 kHz buck power converter. A high resolution digital PWM approach is presented. Additionally a simple and effective solution of filtering of an analog-to-digital converter output is presented.

  1. An Analysis of a Digital Variant of the Trail Making Test Using Machine Learning Techniques

    PubMed Central

    Dahmen, Jessamyn; Cook, Diane; Fellows, Robert; Schmitter-Edgecombe, Maureen

    2017-01-01

    BACKGROUND The goal of this work is to develop a digital version of a standard cognitive assessment, the Trail Making Test (TMT), and assess its utility. OBJECTIVE This paper introduces a novel digital version of the TMT and introduces a machine learning based approach to assess its capabilities. METHODS Using digital Trail Making Test (dTMT) data collected from (N=54) older adult participants as feature sets, we use machine learning techniques to analyze the utility of the dTMT and evaluate the insights provided by the digital features. RESULTS Predicted TMT scores correlate well with clinical digital test scores (r=0.98) and paper time to completion scores (r=0.65). Predicted TICS exhibited a small correlation with clinically-derived TICS scores (r=0.12 Part A, r=0.10 Part B). Predicted FAB scores exhibited a small correlation with clinically-derived FAB scores (r=0.13 Part A, r=0.29 for Part B). Digitally-derived features were also used to predict diagnosis (AUC of 0.65). CONCLUSION Our findings indicate that the dTMT is capable of measuring the same aspects of cognition as the paper-based TMT. Furthermore, the dTMT’s additional data may be able to help monitor other cognitive processes not captured by the paper-based TMT alone. PMID:27886019

  2. Ada Compiler Validation Summary Report: Certificate Number: 940325S1. 11348 DDC-I, DACS Sun SPARC/Solaris to 80386 PM Bare Ada Cross Compiler System, Version 4.6.4 Sun SPARCclassic = Intel iSBC 386/116 (Bare Machine)

    DTIC Science & Technology

    1994-03-25

    digits than SYSTEM.MAXDIGITS: C24113L..Y (14 tests) C35705L..Y (14 tests) C35706L..Y (14 tests) C35707L..Y (14 tests) 2-1 C35708L..Y (14 tests) C35802L...MACHINE CODETYPE : REGISTERTYPE MANTISSADOC : 31 A-2 MAX_- DIGITS : 15 MAX_-INT : 9223372036854775807 MAX_-INTPLUS_1 : 9223372036854775808 MIN_ INT...words. A libary task is formed when a task object is declared at the outermost level of a package. Library tasks ame created and activated during the

  3. Preservation of Earth Science Data History with Digital Content Repository Technology

    NASA Astrophysics Data System (ADS)

    Wei, Y.; Pan, J.; Shrestha, B.; Cook, R. B.

    2011-12-01

    An increasing need for derived and on-demand data product in Earth Science research makes the digital content more difficult for providers to manage and preserve and for users to locate, understand, and consume. Specifically, this increasing need presents additional challenges in managing data processing history information and delivering such information to end users. For example, the North American Carbon Program (NACP) Multi-scale Synthesis and Terrestrial Model Intercomparison Project (MsTMIP) chose a modified SYNMAP land cover data as one of the input driver data for participating terrestrial biospheric models. The global 1km resolution SYNMAP data was created by harmonizing 3 remote sensing-based land cover products: GLCC, GLC2000, and the MODIS land cover product. The original SYNMAP land cover data was aggregated into half and quarter degree resolution. It was then enhanced with more detailed grassland and cropland types. Currently, there lacks an effective mechanism to convey this data processing information to different modeling teams for them to determine if a data product meets their needs. It still highly relies on offline human interaction. The NASA-sponsored ORNL DAAC has leveraged the contemporary digital object repository technology to promote the representation, management, and delivery of data processing history and provenance information. Within digital object repository, different data products are managed as objects, with metadata as attributes and content delivery and management services as dissemination methods. Derivation relationships among data products can be semantically referenced between digital objects. Within the repository, data users can easily track a derived data product back to its origin, explorer metadata and documents about each intermediate data product, and discover processing details involved in each derivation step. Coupled with Drupal Web Content Management System, the digital repository interface was enhanced to provide intuitive graphic representation of the data processing history. Each data product is also associated with a formal metadata record in FGDC standards, and the main fields of the FGDC record are indexed for search, and are displayed as attributes of the data product. These features enable data users to better understand and consume a data product. The representation of data processing history in digital repository can further promote long-term data preservation. Lineage information is a major aspect to make digital data understandable and usable long time into the future. Derivation references can be setup between digital objects not only within a single digital repository, but also across multiple distributed digital repositories. Along with emerging identification mechanisms, such as Digital Object Identifier (DOI), a flexible distributed digital repository network can be setup to better preserve digital content. In this presentation, we describe how digital content repository technology can be used to manage, preserve, and deliver digital data processing history information in Earth Science research domain, with selected data archived in ORNL DAAC and Model and Synthesis Thematic Data Center (MAST-DC) as testing targets.

  4. A Pilot Study for Evaluation of Digital Systems as an Adjunct to Sphygmomanometry for Undergraduate Teaching

    PubMed Central

    Sharma, Renuka; Kapoor, Raj

    2016-01-01

    Objectives: Blood pressure estimation is a key skill for medical practitioners. It is routinely taught to undergraduate medical students using an aneroid sphygmomanometer. However, the conceptual understanding in the practical remains limited. We conducted the following study to evaluate the efficacy of digital data acquisition systems as an adjunct to the sphygmomanometer to teach blood pressure. Methods: Fifty-seven first-year medical students participated in the study. An MCQ test of 15 questions, consisting of 10 conceptual and five factual questions, was administered twice – pre- and post-demonstration of blood pressure measurement using a digital data acquisition system. In addition, qualitative feedback was also obtained. Results: Median scores were 7 (6 - 8) and 3 (1.5 - 4) in pre-test sessions for conceptual and factual questions, respectively. Post-test scores showed a significant improvement in both categories (10 (9 - 10) and 4 (4 - 4.5), respectively, Mann-Whitney U test, p < 0.0001). Student feedback also indicated that the digital system enhanced learning and student participation. Conclusions: Student feedback regarding the demonstrations was uniformly positive, which was also reflected in significantly improved post-test scores. We conclude that parallel demonstration on digital systems and the sphygmomanometer will enhance student engagement and understanding of blood pressure measurement. PMID:27660735

  5. Evaluation of the Geotech SMART24BH 20Vpp/5Vpp data acquisition system with active fortezza crypto card data signing and authentication.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rembold, Randy Kai; Hart, Darren M.

    Sandia National Laboratories has tested and evaluated Geotech SMART24BH borehole data acquisition system with active Fortezza crypto card data signing and authentication. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of two Geotech SMART24BH digitizers with a Fortezza PCMCIAmore » crypto card actively implementing the signing of data packets. The results of this evaluation were compared to relevant specifications provided within manufacturer's documentation notes. The tests performed were chosen to demonstrate different performance aspects of the digitizer under test. The performance aspects tested include determining noise floor, least significant bit (LSB), dynamic range, cross-talk, relative channel-to-channel timing, time-tag accuracy/statistics/drift, analog bandwidth.« less

  6. Evaluation of a digital learning object (DLO) to support the learning process in radiographic dental diagnosis.

    PubMed

    Busanello, F H; da Silveira, P F; Liedke, G S; Arús, N A; Vizzotto, M B; Silveira, H E D; Silveira, H L D

    2015-11-01

    Studies have shown that inappropriate therapeutic strategies may be adopted if crown and root changes are misdiagnosed, potentially leading to undesirable consequences. Therefore, the aim of this study was to evaluate a digital learning object, developed to improve skills in diagnosing radiographic dental changes. The object was developed using the Visual Basic Application (VBA) software and evaluated by 62 undergraduate students (male: 24 and female: 38) taking an imaging diagnosis course. Participants were divided in two groups: test group, which used the object and control group, which attended conventional classes. After 3 weeks, students answered a 10-question test and took a practice test to diagnose 20 changes in periapical radiographs. The results show that test group performed better that control group in both tests, with statistically significant difference (P = 0.004 and 0.003, respectively). In overall, female students were better than male students. Specific aspects of object usability were assessed using a structured questionnaire based on the System Usability Scale (SUS), with a score of 90.5 and 81.6 by male and female students, respectively. The results obtained in this study suggest that students who used the DLO performed better than those who used conventional methods. This suggests that the DLO may be a useful teaching tool for dentistry undergraduates, on distance learning courses and as a complementary tool in face-to-face teaching. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Spatial and visuospatial working memory tests predict performance in classic multiple-object tracking in young adults, but nonspatial measures of the executive do not.

    PubMed

    Trick, Lana M; Mutreja, Rachna; Hunt, Kelly

    2012-02-01

    An individual-differences approach was used to investigate the roles of visuospatial working memory and the executive in multiple-object tracking. The Corsi Blocks and Visual Patterns Tests were used to assess visuospatial working memory. Two relatively nonspatial measures of the executive were used: operation span (OSPAN) and reading span (RSPAN). For purposes of comparison, the digit span test was also included (a measure not expected to correlate with tracking). The tests predicted substantial amounts of variance (R (2) = .33), and the visuospatial measures accounted for the majority (R (2) = .30), with each making a significant contribution. Although the executive measures correlated with each other, the RSPAN did not correlate with tracking. The correlation between OSPAN and tracking was similar in magnitude to that between digit span and tracking (p < .05 for both), and when regression was used to partial out shared variance between the two tests, the remaining variance predicted by the OSPAN was minimal (sr ( 2 ) = .029). When measures of spatial memory were included in the regression, the unique variance predicted by the OSPAN became negligible (sr ( 2 ) = .000004). This suggests that the executive, as measured by tests such as the OSPAN, plays little role in explaining individual differences in multiple-object tracking.

  8. Digital mammography, cancer screening: Factors important for image compression

    NASA Technical Reports Server (NTRS)

    Clarke, Laurence P.; Blaine, G. James; Doi, Kunio; Yaffe, Martin J.; Shtern, Faina; Brown, G. Stephen; Winfield, Daniel L.; Kallergi, Maria

    1993-01-01

    The use of digital mammography for breast cancer screening poses several novel problems such as development of digital sensors, computer assisted diagnosis (CAD) methods for image noise suppression, enhancement, and pattern recognition, compression algorithms for image storage, transmission, and remote diagnosis. X-ray digital mammography using novel direct digital detection schemes or film digitizers results in large data sets and, therefore, image compression methods will play a significant role in the image processing and analysis by CAD techniques. In view of the extensive compression required, the relative merit of 'virtually lossless' versus lossy methods should be determined. A brief overview is presented here of the developments of digital sensors, CAD, and compression methods currently proposed and tested for mammography. The objective of the NCI/NASA Working Group on Digital Mammography is to stimulate the interest of the image processing and compression scientific community for this medical application and identify possible dual use technologies within the NASA centers.

  9. Radar data processing and analysis

    NASA Technical Reports Server (NTRS)

    Ausherman, D.; Larson, R.; Liskow, C.

    1976-01-01

    Digitized four-channel radar images corresponding to particular areas from the Phoenix and Huntington test sites were generated in conjunction with prior experiments performed to collect X- and L-band synthetic aperture radar imagery of these two areas. The methods for generating this imagery are documented. A secondary objective was the investigation of digital processing techniques for extraction of information from the multiband radar image data. Following the digitization, the remaining resources permitted a preliminary machine analysis to be performed on portions of the radar image data. The results, although necessarily limited, are reported.

  10. Anticipatory planning and control of grasp positions and forces for dexterous two-digit manipulation.

    PubMed

    Fu, Qiushi; Zhang, Wei; Santello, Marco

    2010-07-07

    Dexterous object manipulation requires anticipatory control of digit positions and forces. Despite extensive studies on sensorimotor learning of digit forces, how humans learn to coordinate digit positions and forces has never been addressed. Furthermore, the functional role of anticipatory modulation of digit placement to object properties remains to be investigated. We addressed these questions by asking human subjects (12 females, 12 males) to grasp and lift an inverted T-shaped object using precision grip at constrained or self-chosen locations. The task requirement was to minimize object roll during lift. When digit position was not constrained, subjects could have implemented many equally valid digit position-force coordination patterns. However, choice of digit placement might also have resulted in large trial-to-trial variability of digit position, hence challenging the extent to which the CNS could have relied on sensorimotor memories for anticipatory control of digit forces. We hypothesized that subjects would modulate digit placement for optimal force distribution and digit forces as a function of variable digit positions. All subjects learned to minimize object roll within the first three trials, and the unconstrained device was associated with significantly smaller grip forces but larger variability of digit positions. Importantly, however, digit load force modulation compensated for position variability, thus ensuring consistent object roll minimization on each trial. This indicates that subjects learned object manipulation by integrating sensorimotor memories with sensory feedback about digit positions. These results are discussed in the context of motor equivalence and sensorimotor integration of grasp kinematics and kinetics.

  11. Semi-automated extraction of landslides in Taiwan based on SPOT imagery and DEMs

    NASA Astrophysics Data System (ADS)

    Eisank, Clemens; Hölbling, Daniel; Friedl, Barbara; Chen, Yi-Chin; Chang, Kang-Tsung

    2014-05-01

    The vast availability and improved quality of optical satellite data and digital elevation models (DEMs), as well as the need for complete and up-to-date landslide inventories at various spatial scales have fostered the development of semi-automated landslide recognition systems. Among the tested approaches for designing such systems, object-based image analysis (OBIA) stepped out to be a highly promising methodology. OBIA offers a flexible, spatially enabled framework for effective landslide mapping. Most object-based landslide mapping systems, however, have been tailored to specific, mainly small-scale study areas or even to single landslides only. Even though reported mapping accuracies tend to be higher than for pixel-based approaches, accuracy values are still relatively low and depend on the particular study. There is still room to improve the applicability and objectivity of object-based landslide mapping systems. The presented study aims at developing a knowledge-based landslide mapping system implemented in an OBIA environment, i.e. Trimble eCognition. In comparison to previous knowledge-based approaches, the classification of segmentation-derived multi-scale image objects relies on digital landslide signatures. These signatures hold the common operational knowledge on digital landslide mapping, as reported by 25 Taiwanese landslide experts during personal semi-structured interviews. Specifically, the signatures include information on commonly used data layers, spectral and spatial features, and feature thresholds. The signatures guide the selection and implementation of mapping rules that were finally encoded in Cognition Network Language (CNL). Multi-scale image segmentation is optimized by using the improved Estimation of Scale Parameter (ESP) tool. The approach described above is developed and tested for mapping landslides in a sub-region of the Baichi catchment in Northern Taiwan based on SPOT imagery and a high-resolution DEM. An object-based accuracy assessment is conducted by quantitatively comparing extracted landslide objects with landslide polygons that were visually interpreted by local experts. The applicability and transferability of the mapping system are evaluated by comparing initial accuracies with those achieved for the following two tests: first, usage of a SPOT image from the same year, but for a different area within the Baichi catchment; second, usage of SPOT images from multiple years for the same region. The integration of the common knowledge via digital landslide signatures is new in object-based landslide studies. In combination with strategies to optimize image segmentation this may lead to a more objective, transferable and stable knowledge-based system for the mapping of landslides from optical satellite data and DEMs.

  12. State of the Art and Development Trends of the Digital Radiography Systems for Cargo Inspection

    NASA Astrophysics Data System (ADS)

    Udod, V.; Van, J.; Osipov, S.; Chakhlov, S.; Temnik, A.

    2016-01-01

    Increasing requirements for technical parameters of inspection digital radiography systems are caused by increasing incidences of terrorism, drug trafficking and explosives via variety of transport. These requirements have determined research for new technical solutions that enable to ensure the safety of passengers and cargos in real-time. The main efforts in the analyzed method of testing are aimed at the creation of new and modernization of operated now systems of digital radiography as a whole and their main components and elements in particular. The number of these main components and elements includes sources of X-ray recording systems and transformation of radiometric information as well as algorithms and software that implements these algorithms for processing, visualization and results interpretation of inspection. Recent developments of X-ray units and betatrons used for inspection of small- and large-sized objects that are made from different materials are deserve special attention. The most effective X-ray detectors are a line and a radiometric detector matrix based on various scintillators. The most promising methods among the algorithms of material identification of testing objects are dual-energy methods. The article describes various models of digital radiography systems applied in Russia and abroad to inspection of baggage, containers, vehicles and large trucks.

  13. Improved grid-noise removal in single-frame digital moiré 3D shape measurement

    NASA Astrophysics Data System (ADS)

    Mohammadi, Fatemeh; Kofman, Jonathan

    2016-11-01

    A single-frame grid-noise removal technique was developed for application in single-frame digital-moiré 3D shape measurement. The ability of the stationary wavelet transform (SWT) to prevent oscillation artifacts near discontinuities, and the ability of the Fourier transform (FFT) applied to wavelet coefficients to separate grid-noise from useful image information, were combined in a new technique, SWT-FFT, to remove grid-noise from moiré-pattern images generated by digital moiré. In comparison to previous grid-noise removal techniques in moiré, SWT-FFT avoids the requirement for mechanical translation of optical components and capture of multiple frames, to enable single-frame moiré-based measurement. Experiments using FFT, Discrete Wavelet Transform (DWT), DWT-FFT, and SWT-FFT were performed on moiré-pattern images containing grid noise, generated by digital moiré, for several test objects. SWT-FFT had the best performance in removing high-frequency grid-noise, both straight and curved lines, minimizing artifacts, and preserving the moiré pattern without blurring and degradation. SWT-FFT also had the lowest noise amplitude in the reconstructed height and lowest roughness index for all test objects, indicating best grid-noise removal in comparison to the other techniques.

  14. Fringe pattern demodulation with a two-frame digital phase-locked loop algorithm.

    PubMed

    Gdeisat, Munther A; Burton, David R; Lalor, Michael J

    2002-09-10

    A novel technique called a two-frame digital phase-locked loop for fringe pattern demodulation is presented. In this scheme, two fringe patterns with different spatial carrier frequencies are grabbed for an object. A digital phase-locked loop algorithm tracks and demodulates the phase difference between both fringe patterns by employing the wrapped phase components of one of the fringe patterns as a reference to demodulate the second fringe pattern. The desired phase information can be extracted from the demodulated phase difference. We tested the algorithm experimentally using real fringe patterns. The technique is shown to be suitable for noncontact measurement of objects with rapid surface variations, and it outperforms the Fourier fringe analysis technique in this aspect. Phase maps produced withthis algorithm are noisy in comparison with phase maps generated with the Fourier fringe analysis technique.

  15. Launching Discovery through a Digital Library Portal: SIOExplorer

    NASA Astrophysics Data System (ADS)

    Miller, S. P.; Staudigel, H.; Johnson, C.; McSherry, K.; Clark, D.; Peckman, U.; Helly, J.; Sutton, D.; Chase, A.; Schottlaender, B. E.; Day, D.; Helly, M.

    2003-12-01

    The launching of an oceanographic expedition has its own brand of excitement, with the sound of the main engines firing up, and the lifting of the gangway in a foreign port, as the team of scientists and crew sets out for a month at sea with only the resources they have aboard. Although this adventure is broadly appealing, very few have the privilege of actually joining an expedition. With the "SIOExplorer" family of projects we are now beginning to open this experience across cyberspace to a wide range of students and teachers. What began two years ago as an effort to stabilize the Scripps Institution of Oceanography (SIO) data archives from more than 700 cruises going back 50 years, has now become an operational component of the National Science Digital Library (NSDL; www.nsdl.org), complete with thousands of historic photographs, full text documents and 3D visualization experiences. Our initial emphasis has been on marine geology and geophysics, in particular multibeam seafloor mapping, including 2 terabytes of digital objects. The IT architecture implemented at the San Diego Supercomputer Center (SDSC) streamlines the integration of additional projects in other disciplines with a suite of metadata management and collection building tools for "arbitrary digital objects." The "CruiseViewer" Java application is the primary portal to the digital library, providing a graphical user and display interface, the interface with the metadata database, and the interface with the SDSC "Storage Resource Broker" for long-term bulk distributed data storage management. It presents the user with a view of the available objects, overlaid on a global topography map. Geospatial objects can be selected interactively, and searches can be constrained by keywords. Metadata can be browsed and objects can be viewed onscreen or downloaded for further analysis, with automatic proprietary-hold request management. These efforts will be put to the test with national teacher workshops in the next two summers. Teachers, in collaboration with SIO-graduate students, will prepare and field-test learning-experience modules that explore concepts from plate tectonics theory for classroom and web use. Students will design their own personal voyages of discovery through our digital archives, promoting inquiry-based learning tailored to each individual. Future education and outreach efforts will include 1) developing a global registry of seafloor research or education projects (academic, industry, government), allowing at least a URL and a contact for further information 2) adding new collections, including dredged rocks and cores, 3) interoperating with other international data collections, 4) interacting with education and outreach projects such as the California Center for Ocean Science Education Excellence (COSEE), 5) continued testing of a real-time stand-alone digital library on a laptop shipboard acquisition system, 6) enhanced use of real-time Real-time Observatories, Applications, and Data management Network (ROADnet) satellite links to SIO vessels, and 7) continued construction of a series of museum exhibits based on digital terrain models. Now that SIOExplorer has become operational, we look forward to collaborating with other institutions for data and technology exchange, as well as for education and outreach opportunities. Support is provided by NSF NSDL, ITR and OCE programs, as well as by UCSD funds.

  16. Fault detection and accommodation testing on an F100 engine in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Myers, L. P.; Baer-Riedhart, J. L.; Maxwell, M. D.

    1985-01-01

    The fault detection and accommodation (FDA) methodology for digital engine-control systems may range from simple comparisons of redundant parameters to the more complex and sophisticated observer models of the entire engine system. Evaluations of the various FDA schemes are done using analytical methods, simulation, and limited-altitude-facility testing. Flight testing of the FDA logic has been minimal because of the difficulty of inducing realistic faults in flight. A flight program was conducted to evaluate the fault detection and accommodation capability of a digital electronic engine control in an F-15 aircraft. The objective of the flight program was to induce selected faults and evaluate the resulting actions of the digital engine controller. Comparisons were made between the flight results and predictions. Several anomalies were found in flight and during the ground test. Simulation results showed that the inducement of dual pressure failures was not feasible since the FDA logic was not designed to accommodate these types of failures.

  17. Research on measurement method of optical camouflage effect of moving object

    NASA Astrophysics Data System (ADS)

    Wang, Juntang; Xu, Weidong; Qu, Yang; Cui, Guangzhen

    2016-10-01

    Camouflage effectiveness measurement as an important part of the camouflage technology, which testing and measuring the camouflage effect of the target and the performance of the camouflage equipment according to the tactical and technical requirements. The camouflage effectiveness measurement of current optical band is mainly aimed at the static target which could not objectively reflect the dynamic camouflage effect of the moving target. This paper synthetical used technology of dynamic object detection and camouflage effect detection, the digital camouflage of the moving object as the research object, the adaptive background update algorithm of Surendra was improved, a method of optical camouflage effect detection using Lab-color space in the detection of moving-object was presented. The binary image of moving object is extracted by this measurement technology, in the sequence diagram, the characteristic parameters such as the degree of dispersion, eccentricity, complexity and moment invariants are constructed to construct the feature vector space. The Euclidean distance of moving target which through digital camouflage was calculated, the results show that the average Euclidean distance of 375 frames was 189.45, which indicated that the degree of dispersion, eccentricity, complexity and moment invariants of the digital camouflage graphics has a great difference with the moving target which not spray digital camouflage. The measurement results showed that the camouflage effect was good. Meanwhile with the performance evaluation module, the correlation coefficient of the dynamic target image range 0.1275 from 0.0035, and presented some ups and down. Under the dynamic condition, the adaptability of target and background was reflected. In view of the existing infrared camouflage technology, the next step, we want to carry out the camouflage effect measurement technology of the moving target based on infrared band.

  18. Scanning for Digitization Projects

    ERIC Educational Resources Information Center

    Wentzel, Larry

    2007-01-01

    Librarians and archivists find themselves facing the prospect of digitization. Everyone is doing it, everyone needs it. Discussions rage nationally and internationally concerning what to digitize and the best means to present and retain digital objects. Digitization is the act of making something digital, expressing a physical object "in numerical…

  19. Performance seeking control program overview

    NASA Technical Reports Server (NTRS)

    Orme, John S.

    1995-01-01

    The Performance Seeking Control (PSC) program evolved from a series of integrated propulsion-flight control research programs flown at NASA Dryden Flight Research Center (DFRC) on an F-15. The first of these was the Digital Electronic Engine Control (DEEC) program and provided digital engine controls suitable for integration. The DEEC and digital electronic flight control system of the NASA F-15 were ideally suited for integrated controls research. The Advanced Engine Control System (ADECS) program proved that integrated engine and aircraft control could improve overall system performance. The objective of the PSC program was to advance the technology for a fully integrated propulsion flight control system. Whereas ADECS provided single variable control for an average engine, PSC controlled multiple propulsion system variables while adapting to the measured engine performance. PSC was developed as a model-based, adaptive control algorithm and included four optimization modes: minimum fuel flow at constant thrust, minimum turbine temperature at constant thrust, maximum thrust, and minimum thrust. Subsonic and supersonic flight testing were conducted at NASA Dryden covering the four PSC optimization modes and over the full throttle range. Flight testing of the PSC algorithm, conducted in a series of five flight test phases, has been concluded at NASA Dryden covering all four of the PSC optimization modes. Over a three year period and five flight test phases 72 research flights were conducted. The primary objective of flight testing was to exercise each PSC optimization mode and quantify the resulting performance improvements.

  20. EMPTAC (Electromagnetic Pulse Test Aircraft) User’s Guide.

    DTIC Science & Technology

    1988-04-01

    8217Jhe 5 JJ 5 1.2 OBJECTIVES - Elf , The objectives of this document are to: 0 Point out major areas of interest which a user must consider while planning...to bridge the gap between the research and development (R&D) and the operational communities . It provides a vehicle to demonstrate and correlate the...digital communication from the ALT. The test responses are processed through the signal conditioners of the ALT and routed to the ALR. From the ALR

  1. Single-exposure super-resolved interferometric microscopy by RGB multiplexing in lensless configuration

    NASA Astrophysics Data System (ADS)

    Granero, Luis; Ferreira, Carlos; Zalevsky, Zeev; García, Javier; Micó, Vicente

    2016-07-01

    Single-Exposure Super-Resolved Interferometric Microscopy (SESRIM) reports on a way to achieve one-dimensional (1-D) superresolved imaging in digital holographic microscopy (DHM) by a single illumination shot and digital recording. SESRIM provides color-coded angular multiplexing of the accessible sample's range of spatial frequencies and it allows their recording in a single CCD (color or monochrome) snapshot by adding 3 RGB coherent reference beams at the output plane. In this manuscript, we extend the applicability of SESRIM to the field of digital in-line holographic microscopy (DIHM), that is, working without lenses. As consequence of the in-line configuration, an additional restriction concerning the object field of view (FOV) must be imposed to the technique. Experimental results are reported for both a synthetic object (USAF resolution test target) and a biological sample (swine sperm sample) validating this new kind of superresolution imaging method named as lensless SESRIM (L-SESRIM).

  2. Representing Value as Digital Object: A Discussion of Transferability and Anonymity; Digital Library Initiatives of the Deutsche Forschungsgemeinschaft; CrossRef Turns One; Fermi National Accelerator Laboratory (Fermilab).

    ERIC Educational Resources Information Center

    Kahn, Robert E.; Lyons, Patrice A.; Brahms, Ewald; Brand, Amy; van den Bergen, Mieke

    2001-01-01

    Includes four articles that discuss the use of digital objects to represent value in a network environment; digital library initiatives at the central public funding organization for academic research in Germany; an application of the Digital Object Identifier System; and the Web site of the Fermi National Accelerator Laboratory. (LRW)

  3. Optical digitizing and strategies to combine different views of an optical sensor

    NASA Astrophysics Data System (ADS)

    Duwe, Hans P.

    1997-09-01

    Non-contact digitization of objects and surfaces with optical sensors based on fringe or pattern projection in combination with a CCD-camera allows a representation of surfaces with pointclouds equals x, y, z data points. To digitize the total surface of an object, it is necessary to combine the different measurement data obtained by the optical sensor from different views. Depending on the size of the object and the required accuracy of the measured data, different sensor set-ups with handling system or a combination of linear and rotation axes are described. Furthermore, strategies to match the overlapping pointclouds of a digitized object are introduced. This is very important especially for the digitization of large objects like 1:1 car models, etc. With different sensor sizes, it is possible to digitize small objects like teeth, crowns, inlays, etc. with an overall accuracy of 20 micrometer as well as large objects like car models, with a total accuracy of 0.5 mm. The various applications in the field of optical digitization are described.

  4. Determination of the resolution of a digital system for panoramic radiography based on CCD technology.

    PubMed

    Mastoris, Mihalis; Li, Gang; Welander, Ulf; McDavid, W D

    2004-03-01

    To determine Line Spread Functions (LSFs) and Modulation Transfer Functions (MTFs) for a digital system for panoramic radiography: the Dimax I (Planmeca Oy, Helsinki, Finland) based on Charge-Coupled Device (CCD) technology. A test object was specially designed having a gold foil positioned vertically. Images of the gold foil created edge functions that were used to determine LSFs and MTFs. The design of the test object made it possible to move the gold foil forward and backward relative to the central plane of the image layer by means of a micrometer screw. The experiment was carried out for different object depths in 5 different regions: the anterior, the canine, the premolar, the molar, and the TMJ regions. LSFs and MTFs were calculated using specially designed software. The results are presented graphically. LSFs and MTFs for the central plane were essentially the same for all regions. The MTFs for different object depths in the 5 investigated regions exhibited typical characteristics of MTFs for panoramic radiography with the exception for the functions for the molar region. The present findings indicate that the resolution of the Dimax I CCD system is comparable to that of film-based panoramic radiography.

  5. Performance of residents using digital images versus glass slides on certification examination in anatomical pathology: a mixed methods pilot study

    PubMed Central

    Mirham, Lorna; Naugler, Christopher; Hayes, Malcolm; Ismiil, Nadia; Belisle, Annie; Sade, Shachar; Streutker, Catherine; MacMillan, Christina; Rasty, Golnar; Popovic, Snezana; Joseph, Mariamma; Gabril, Manal; Barnes, Penny; Hegele, Richard G.; Carter, Beverley; Yousef, George M.

    2016-01-01

    Background: It is anticipated that many licensing examination centres for pathology will begin fully digitizing the certification examinations. The objective of our study was to test the feasibility of a fully digital examination and to assess the needs, concerns and expectations of pathology residents in moving from a glass slide-based examination to a fully digital examination. Methods: We conducted a mixed methods study that compared, after randomization, the performance of senior residents (postgraduate years 4 and 5) in 7 accredited anatomical pathology training programs across Canada on a pathology examination using either glass slides or digital whole-slide scanned images of the slides. The pilot examination was followed by a post-test survey. In addition, pathology residents from all levels of training were invited to participate in an online survey. Results: A total of 100 residents participated in the pilot examination; 49 were given glass slides instead of digital images. We found no significant difference in examination results between the 2 groups of residents (estimated marginal mean 8.23/12, 95% confidence interval [CI] 7.72-8.87, for glass slides; 7.84/12, 95% CI 7.28-8.41, for digital slides). In the post-test survey, most of the respondents expressed concerns with the digital examination, including slowly functioning software, blurring and poor detail of images, particularly nuclear features. All of the respondents of the general survey (n = 179) agreed that additional training was required if the examination were to become fully digital. Interpretation: Although the performance of residents completing pathology examinations with glass slides was comparable to that of residents using digital images, our study showed that residents were not comfortable with the digital technology, especially given their current level of exposure to it. Additional training may be needed before implementing a fully digital examination, with consideration for a gradual transition. PMID:27280119

  6. Audit of a Scientific Data Center for Certification as a Trustworthy Digital Repository: A Case Study

    NASA Astrophysics Data System (ADS)

    Downs, R. R.; Chen, R. S.

    2011-12-01

    Services that preserve and enable future access to scientific data are necessary to ensure that the data that are being collected today will be available for use by future generations of scientists. Many data centers, archives, and other digital repositories are working to improve their ability to serve as long-term stewards of scientific data. Trust in sustainable data management and preservation capabilities of digital repositories can influence decisions to use these services to deposit or obtain scientific data. Building on the Open Archival Information System (OAIS) Reference Model developed by the Consultative Committee for Space Data Systems (CCSDS) and adopted by the International Organization for Standardization as ISO 14721:2003, new standards are being developed to improve long-term data management processes and documentation. The Draft Information Standard ISO/DIS 16363, "Space data and information transfer systems - Audit and certification of trustworthy digital repositories" offers the potential to evaluate digital repositories objectively in terms of their trustworthiness as long-term stewards of digital resources. In conjunction with this, the CCSDS and ISO are developing another draft standard for the auditing and certification process, ISO/DIS 16919, "Space data and information transfer systems - Requirements for bodies providing audit and certification of candidate trustworthy digital repositories". Six test audits were conducted of scientific data centers and archives in Europe and the United States to test the use of these draft standards and identify potential improvements for the standards and for the participating digital repositories. We present a case study of the test audit conducted on the NASA Socioeconomic Data and Applications Center (SEDAC) and describe the preparation, the audit process, recommendations received, and next steps to obtain certification as a trustworthy digital repository, after approval of the ISO/DIS standards.

  7. Spatial-Heterodyne Interferometry For Reflection And Transm Ission (Shirt) Measurements

    DOEpatents

    Hanson, Gregory R [Clinton, TN; Bingham, Philip R [Knoxville, TN; Tobin, Ken W [Harriman, TN

    2006-02-14

    Systems and methods are described for spatial-heterodyne interferometry for reflection and transmission (SHIRT) measurements. A method includes digitally recording a first spatially-heterodyned hologram using a first reference beam and a first object beam; digitally recording a second spatially-heterodyned hologram using a second reference beam and a second object beam; Fourier analyzing the digitally recorded first spatially-heterodyned hologram to define a first analyzed image; Fourier analyzing the digitally recorded second spatially-heterodyned hologram to define a second analyzed image; digitally filtering the first analyzed image to define a first result; and digitally filtering the second analyzed image to define a second result; performing a first inverse Fourier transform on the first result, and performing a second inverse Fourier transform on the second result. The first object beam is transmitted through an object that is at least partially translucent, and the second object beam is reflected from the object.

  8. Objective criteria for acceptability and constancy tests of digital subtraction angiography.

    PubMed

    de las Heras, Hugo; Torres, Ricardo; Fernández-Soto, José Miguel; Vañó, Eliseo

    2016-01-01

    Demonstrate an objective procedure to quantify image quality in digital subtraction angiography (DSA) and suggest thresholds for acceptability and constancy tests. Series of images were obtained in a DSA system simulating a small (paediatric) and a large patient using the dynamic phantom described in the IEC and DIN standards for acceptance tests of DSA equipment. Image quality was quantified using measurements of contrast-to-noise ratio (CNR). Overall scores combining the CNR of 10-100 mg/ml Iodine at a vascular diameter of 1-4 mm in a homogeneous background were defined. Phantom entrance surface air kerma (Ka,e) was measured with an ionisation chamber. The visibility of a low-contrast vessel in DSA images has been identified with a CNR value of 0.50 ± 0.03. Despite using 14 times more Ka,e (8.85 vs 0.63 mGy/image), the protocol for large patients showed a decrease in the overall score CNRsum of 67% (4.21 ± 0.06 vs 2.10 ± 0.05). The uncertainty in the results of the objective method was below 5%. Objective evaluation of DSA images using CNR is feasible with dedicated phantom measurements. An objective methodology has been suggested for acceptance tests compliant with the IEC/DIN standards. The defined overall scores can serve to fix a reproducible baseline for constancy tests, as well as to study the device stability within one acquisition series and compare different imaging protocols. This work provides aspects that have not been included in the recent European guidelines on Criteria for Acceptability of Medical Radiological Equipment. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  9. Comparison of neurocognitive results after coronary artery bypass grafting and thoracic aortic surgery using retrograde cerebral perfusion.

    PubMed

    Miyairi, Takeshi; Takamoto, Shinichi; Kotsuka, Yutaka; Takeuchi, Atsuko; Yamanaka, Katsuo; Sato, Hajime

    2005-07-01

    Retrograde cerebral perfusion (RCP) is used as an adjunctive method to hypothermic circulatory arrest to enhance cerebral protection in patients undergoing thoracic aortic surgery. It remains unclear whether RCP provides improved neurological and neuropsychological outcome. Forty-six patients undergoing thoracic aortic surgery using RCP, and 28 undergoing coronary artery bypass grafting (CABG; n = 28) with CPB, were enrolled in the study. Patients receiving RCP were subdivided into two groups, those with less than 60 min of RCP (S-RCP; n = 27) and with 60 min or more (L-RCP; n = 19). The patients' neurocognitive state was assessed by the revised Wechsler Adult Intelligence Scale a few days before operation, at 2-3 weeks and 4-6 months after operation. There were no stroke, seizure, and hospital mortality in either group. Significant decline between baseline and early scores were seen in three subtests (digit span, arithmetic, and picture completion) for S-RCP and four (digit span, arithmetic, picture completion, and picture arrangement) for L-RCP. Significant decline between baseline and late scores were seen in one subtest (arithmetic) for S-RCP, four (digit span, arithmetic, picture completion, and picture arrangement) for L-RCP, and one (object assembly) for CABG. The mean change of scores for one late test (digit symbol) was significantly lower in S-RCP than in CABG. The mean change of scores for three early tests (digit span, vocabulary, and picture arrangement) and four late tests (information, digit span, picture completion, and picture arrangement) were significantly lower in L-RCP than in CABG. Stepwise logistic regression analysis disclosed that, after considering the other variables, significant difference in test score changes were observed between CABG and L-RCP for two early tests (picture completion and digit symbol) as well as for three late tests (digit span, similarities, and picture completion). None of test score changes showed significant difference between CABG and S-RCP. The neurocognitive outcome in patients undergoing RCP less than 60 min were comparable with patients undergoing CABG without circulatory arrest. Prolonged RCP of 60 min or more in patients undergoing surgery of the thoracic aorta was associated with postoperative neurocognitive impairment.

  10. Ecological validity of the five digit test and the oral trails test.

    PubMed

    Paiva, Gabrielle Chequer de Castro; Fialho, Mariana Braga; Costa, Danielle de Souza; Paula, Jonas Jardim de

    2016-01-01

    Tests evaluating the attentional-executive system are widely used in clinical practice. However, proximity of an objective cognitive test with real-world situations (ecological validity) is not frequently investigated. The present study evaluate the association between measures of the Five Digit Test (FDT) and the Oral Trails Test (OTT) with self-reported cognitive failures in everyday life as measured by the Cognitive Failures Questionnaire (CFQ). Brazilian adults from 18-to-65 years old voluntarily performed the FDT and OTT tests and reported the frequency of cognitive failures in their everyday life through the CFQ. After controlling for the age effect, the measures of controlled attentional processes were associated with cognitive failures, yet the cognitive flexibility of both FDT and OTT accounted for by the majority of variance in most aspects of the CFQ factors. The FDT and the OTT measures were predictive of real-world problems such as cognitive failures in everyday activities/situations.

  11. Evaluation of Inter-Mountain Labs infrasound sensors : July 2007.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hart, Darren M.

    2007-10-01

    Sandia National Laboratories has tested and evaluated three Inter Mountain Labs infrasound sensors. The test results included in this report were in response to static and tonal-dynamic input signals. Most test methodologies used were based on IEEE Standards 1057 for Digitizing Waveform Recorders and 1241 for Analog to Digital Converters; others were designed by Sandia specifically for infrasound application evaluation and for supplementary criteria not addressed in the IEEE standards. The objective of this work was to evaluate the overall technical performance of the Inter Mountain Labs (IML) infrasound sensor model SS. The results of this evaluation were only comparedmore » to relevant noise models; due to a lack of manufactures documentation notes on the sensors under test prior to testing. The tests selected for this system were chosen to demonstrate different performance aspects of the components under test.« less

  12. D Reconstruction of AN Underwater Archaelogical Site: Comparison Between Low Cost Cameras

    NASA Astrophysics Data System (ADS)

    Capra, A.; Dubbini, M.; Bertacchini, E.; Castagnetti, C.; Mancini, F.

    2015-04-01

    The 3D reconstruction with a metric content of a submerged area, where objects and structures of archaeological interest are found, could play an important role in the research and study activities and even in the digitization of the cultural heritage. The reconstruction of 3D object, of interest for archaeologists, constitutes a starting point in the classification and description of object in digital format and for successive fruition by user after delivering through several media. The starting point is a metric evaluation of the site obtained with photogrammetric surveying and appropriate 3D restitution. The authors have been applying the underwater photogrammetric technique since several years using underwater digital cameras and, in this paper, digital low cost cameras (off-the-shelf). Results of tests made on submerged objects with three cameras are presented: Canon Power Shot G12, Intova Sport HD e GoPro HERO 2. The experimentation had the goal to evaluate the precision in self-calibration procedures, essential for multimedia underwater photogrammetry, and to analyze the quality of 3D restitution. Precisions obtained in the calibration and orientation procedures was assessed by using three cameras, and an homogeneous set control points. Data were processed with Agisoft Photoscan. Successively, 3D models were created and the comparison of the models derived from the use of different cameras was performed. Different potentialities of the used cameras are reported in the discussion section. The 3D restitution of objects and structures was integrated with sea bottom floor morphology in order to achieve a comprehensive description of the site. A possible methodology of survey and representation of submerged objects is therefore illustrated, considering an automatic and a semi-automatic approach.

  13. Evaluation of a miniature microscope objective designed for fluorescence array microscopy detection of Mycobacterium tuberculosis.

    PubMed

    McCall, Brian; Olsen, Randall J; Nelles, Nicole J; Williams, Dawn L; Jackson, Kevin; Richards-Kortum, Rebecca; Graviss, Edward A; Tkaczyk, Tomasz S

    2014-03-01

    A prototype miniature objective that was designed for a point-of-care diagnostic array microscope for detection of Mycobacterium tuberculosis and previously fabricated and presented in a proof of concept is evaluated for its effectiveness in detecting acid-fast bacteria. To evaluate the ability of the microscope to resolve submicron features and details in the image of acid-fast microorganisms stained with a fluorescent dye, and to evaluate the accuracy of clinical diagnoses made with digital images acquired with the objective. The lens prescription data for the microscope design are presented. A test platform is built by combining parts of a standard microscope, a prototype objective, and a digital single-lens reflex camera. Counts of acid-fast bacteria made with the prototype objective are compared to counts obtained with a standard microscope over matched fields of view. Two sets of 20 smears, positive and negative, are diagnosed by 2 pathologists as sputum smear positive or sputum smear negative, using both a standard clinical microscope and the prototype objective under evaluation. The results are compared to a reference diagnosis of the same sample. More bacteria are counted in matched fields of view in digital images taken with the prototype objective than with the standard clinical microscope. All diagnostic results are found to be highly concordant. An array microscope built with this miniature lens design will be able to detect M tuberculosis with high sensitivity and specificity.

  14. The application of digital image plane holography technology to identify Chinese herbal medicine

    NASA Astrophysics Data System (ADS)

    Wang, Huaying; Guo, Zhongjia; Liao, Wei; Zhang, Zhihui

    2012-03-01

    In this paper, the imaging technology of digital image plane holography to identify the Chinese herbal medicine is studied. The optical experiment system of digital image plane holography which is the special case of pre-magnification digital holography was built. In the record system, one is an object light by using plane waves which illuminates the object, and the other one is recording hologram by using spherical light wave as reference light. There is a Micro objective lens behind the object. The second phase factor which caus ed by the Micro objective lens can be eliminated by choosing the proper position of the reference point source when digital image plane holography is recorded by spherical light. In this experiment, we use the Lygodium cells and Onion cells as the object. The experiment results with Lygodium cells and Onion cells show that digital image plane holography avoid the process of finding recording distance by using auto-focusing approach, and the phase information of the object can be reconstructed more accurately. The digital image plane holography is applied to the microscopic imaging of cells more effectively, and it is suit to apply for the identify of Chinese Herbal Medicine. And it promotes the application of digital holographic in practice.

  15. Motion Controllers for Learners to Manipulate and Interact with 3D Objects for Mental Rotation Training

    ERIC Educational Resources Information Center

    Yeh, Shih-Ching; Wang, Jin-Liang; Wang, Chin-Yeh; Lin, Po-Han; Chen, Gwo-Dong; Rizzo, Albert

    2014-01-01

    Mental rotation is an important spatial processing ability and an important element in intelligence tests. However, the majority of past attempts at training mental rotation have used paper-and-pencil tests or digital images. This study proposes an innovative mental rotation training approach using magnetic motion controllers to allow learners to…

  16. A Content Standard for Computational Models; Digital Rights Management (DRM) Architectures; A Digital Object Approach to Interoperable Rights Management: Finely-Grained Policy Enforcement Enabled by a Digital Object Infrastructure; LOCKSS: A Permanent Web Publishing and Access System; Tapestry of Time and Terrain.

    ERIC Educational Resources Information Center

    Hill, Linda L.; Crosier, Scott J.; Smith, Terrence R.; Goodchild, Michael; Iannella, Renato; Erickson, John S.; Reich, Vicky; Rosenthal, David S. H.

    2001-01-01

    Includes five articles. Topics include requirements for a content standard to describe computational models; architectures for digital rights management systems; access control for digital information objects; LOCKSS (Lots of Copies Keep Stuff Safe) that allows libraries to run Web caches for specific journals; and a Web site from the U.S.…

  17. Kyiv UkrVO glass archives: new life

    NASA Astrophysics Data System (ADS)

    Pakuliak, L.; Golovnya, V.; Andruk, V.; Shatokhina, S.; Yizhakevych, O.; Kazantseva, L.; Lukianchuk, V.

    In the framework of UkrVO national project the new methods of plate digital image processing are developed. The photographic material of the UkrVO Joint Digital Archive (JDA) is used for the solution of classic astrometric problem - positional and photometric determinations of objects registered on the plates. The results of tested methods show that the positional rms errors are better than ±150 mas for both coordinates and photometric ones are better than ±0.20m with the Tycho-2 catalogue as reference.

  18. Applications of flight control system methods to an advanced combat rotorcraft

    NASA Technical Reports Server (NTRS)

    Tischler, Mark B.; Fletcher, Jay W.; Morris, Patrick M.; Tucker, George T.

    1989-01-01

    Advanced flight control system design, analysis, and testing methodologies developed at the Ames Research Center are applied in an analytical and flight test evaluation of the Advanced Digital Optical Control System (ADOCS) demonstrator. The primary objectives are to describe the knowledge gained about the implications of digital flight control system design for rotorcraft, and to illustrate the analysis of the resulting handling-qualities in the context of the proposed new handling-qualities specification for rotorcraft. Topics covered in-depth are digital flight control design and analysis methods, flight testing techniques, ADOCS handling-qualities evaluation results, and correlation of flight test results with analytical models and the proposed handling-qualities specification. The evaluation of the ADOCS demonstrator indicates desirable response characteristics based on equivalent damping and frequency, but undersirably large effective time-delays (exceeding 240 m sec in all axes). Piloted handling-qualities are found to be desirable or adequate for all low, medium, and high pilot gain tasks; but handling-qualities are inadequate for ultra-high gain tasks such as slope and running landings.

  19. Common modular avionics - Partitioning and design philosophy

    NASA Astrophysics Data System (ADS)

    Scott, D. M.; Mulvaney, S. P.

    The design objectives and definition criteria for common modular hardware that will perform digital processing functions in multiple avionic subsystems are examined. In particular, attention is given to weapon system-level objectives, such as increased supportability, reduced life cycle costs, and increased upgradability. These objectives dictate the following overall modular design goals: reduce test equipment requirements; have a large number of subsystem applications; design for architectural growth; and standardize for technology transparent implementations. Finally, specific partitioning criteria are derived on the basis of the weapon system-level objectives and overall design goals.

  20. An analysis of packaging formats for complex digtal objects: review of principles

    NASA Astrophysics Data System (ADS)

    Bekaert, Jeroen L.; Hochstenbach, Patrick; De Kooning, Emiel; Van de Walle, Rik

    2003-11-01

    During recent years, the number of organizations making digital information available has massively increased. This evolution encouraged the development of standards for packaging and encoding digital representations of complex objects (such as a digital music albums or digitized books and photograph albums). The primary goal of this article is to offer a method to compare these packaging standards and best practices tailored to the needs of the digital library community and the rising digital preservation programs. The contribution of this paper is the definition of an integrated reference model, based on both the OAIS framework and some additional significant properties that affect the quality, usability, encoding and behavior of the digital objects.

  1. Digital stethoscope as an innovative tool on the teaching of auscultatory skills.

    PubMed

    Mesquita, Claudio Tinoco; Reis, Jader Costa dos; Simões, Luciana Silveira; Moura, Eduardo Cardoso de; Rodrigues, Gustavo Amarante; Athayde, Carolina Cunto de; Machado, Hugo Lima; Lanzieri, Pedro Gemal

    2013-02-01

    Physical cardiovascular examination, particularly cardiac auscultation, is one of the most difficult clinical skills for students during their medical training. Studies suggest that the use of technologies such as digital stethoscope increase the accuracy of clinical examination, however, its impact on the teaching of cardiac auscultation for undergraduate students of medicine is not known. The objective is to demonstrate the usefulness of the digital stethoscope compared to traditional methods as a tool in the teaching of auscultatory skills. nterventional, longitudinal, controlled, unicenter and randomized study. Thirty-eight medicine students were enrolled for a cardiovascular semiology course lasting eight weeks. The course program included lectures and bedside practice in Cardiology wards. In the practical lessons, the students were randomized into two groups: 1) (n = 21) digital stethoscope (Littmann® Model 3200, 3M); and 2) (n = 17) conventional stethoscopes. A pre-training evaluation was conducted through a test using the software Heart Sounds®, which was repeated after the course. The average scores were compared by paired T test and unpaired T test. It is observed that, at the end of the course, there was a significantly greater improvement in the group that used the digital stethoscope (51.9%) compared to the group using the conventional stethoscope (29.5%). Short-term interventions for cardiac semiology teaching are able to contribute significantly to improving proficiency in the identification of heart sounds. The use of digital stethoscope proved to be a positive factor in teaching these skills.

  2. Brazilian preliminary norms and investigation of age and education effects on the Modified Wisconsin Card Sorting Test, Stroop Color and Word test and Digit Span test in adults

    PubMed Central

    Zimmermann, Nicolle; Cardoso, Caroline de Oliveira; Trentini, Clarissa Marceli; Grassi-Oliveira, Rodrigo; Fonseca, Rochele Paz

    2015-01-01

    Executive functions are involved in a series of human neurological and psychiatric disorders. For this reason, appropriate assessment tools with age and education adjusted norms for symptom diagnosis are necessary. Objective To present normative data for adults (19-75 year-olds; with five years of education or more) on the Modified Wisconsin Card Sorting Test (MWCST), Stroop color and word test and Digit Span test. Age and education effects were investigated. Methods Three samples were formed after inclusion criteria and data analysis: MWCST (n=124); Digit Span (n=123), and Stroop test (n=158). Groups were divided into young (19-39), middle-aged (40-59) and older (60-75) participants with five to eight years of education and nine years of education or more. Two-way ANOVA and ANCOVA analyses were used. Results Education effects were found in most variables of the three tasks. An age effect was only found on color naming and color-word naming speed from the Stroop test. No interactions were detected. Conclusion In countries with heterogeneous educational backgrounds, the use of stratified norms by education to assess at least some components of executive functions is essential for an ethical and accurate cognitive diagnosis. PMID:29213953

  3. In vitro attenuation of impact shock in equine digits.

    PubMed

    Lanovaz, J L; Clayton, H M; Watson, L G

    1998-09-01

    This study was designed to test the impact characteristics of the equine digit in vitro with the objective of providing a better understanding of the role of the digital structures in the attenuation of impact shock. Uni-axial accelerometers were mounted on cadaver digits on the distolateral hoof wall, the proximolateral hoof wall, the dorsal surface of the second phalanx, and the mid-lateral first phalanx. The hoof-mounted accelerometers were aligned with the hoof tubules while the bone-mounted accelerometers were oriented along the longitudinal axis of the bone. Each digit was mounted in a test apparatus designed to simulate impact of the hoof with the ground during locomotion. The digits were subjected to 3 impact trials against a barrier at each of 3 vertical impact velocities that simulated a forward trotting velocity in the range of 2.67 to 4.46 m/s. The impact deceleration tended to increase with impact velocity. Attenuation of the impact shock by the digital tissues resulted in a reduction in impact decleration in the more proximal measuring locations. The interphalangeal joints appeared to play a larger role in amplitude attenuation than the hoof wall or the soft tissue structures within the hoof wall. The signal frequency data showed that the soft tissues within the hoof acted as a 'lowpass' filter, attenuating the higher deceleration frequencies. The hoof wall and the interphalangeal joints showed little frequency attenuation.

  4. Data Concentrator

    NASA Technical Reports Server (NTRS)

    Willett, Mike

    2015-01-01

    Orbital Research, Inc., developed, built, and tested three high-temperature components for use in the design of a data concentrator module in distributed turbine engine control. The concentrator receives analog and digital signals related to turbine engine control and communicates with a full authority digital engine control (FADEC) or high-level command processor. This data concentrator follows the Distributed Engine Controls Working Group (DECWG) roadmap for turbine engine distributed controls communication development that operates at temperatures at least up to 225 C. In Phase I, Orbital Research developed detailed specifications for each component needed for the system and defined the total system specifications. This entailed a combination of system design, compiling existing component specifications, laboratory testing, and simulation. The results showed the feasibility of the data concentrator. Phase II of this project focused on three key objectives. The first objective was to update the data concentrator design modifications from DECWG and prime contractors. Secondly, the project defined requirements for the three new high-temperature, application-specific integrated circuits (ASICs): one-time programmable (OTP), transient voltage suppression (TVS), and 3.3V. Finally, the project validated each design by testing over temperature and under load.

  5. [Digital vs. analog hearing aids for children. Is there a method for making an objective comparison possible?].

    PubMed

    Prinz, I; Nubel, K; Gross, M

    2002-09-01

    Until now, the assumed benefits of digital hearing aids are reflected only in subjective descriptions by patients with hearing aids, but cannot be documented adequately by routine diagnostic methods. Seventeen schoolchildren with moderate severe bilateral symmetrical sensorineural hearing loss were examined in a double-blinded crossover study. Differences in performance between a fully digital hearing aid (DigiFocus compact/Oticon) and an analogous digitally programmable two-channel hearing aid were evaluated. Of the 17 children, 13 choose the digital and 4 the analogous hearing aid. In contrast to the clear subjective preferences for the fully digital hearing aid, we could not obtain any significant results with routine diagnostic methods. Using the "virtual hearing aid," a subjective comparison and speech recognition performance task yielded significant differences. The virtual hearing aid proved to be suitable for a direct comparison of different hearing aids and can be used for double-blind testing in a pediatric population.

  6. X-ray radiation detectors of ``scintillator-photoreceiving device type'' for industrial digital radiography with improved spatial resolution

    NASA Astrophysics Data System (ADS)

    Ryzhykov, V. D.; Lysetska, O. K.; Opolonin, O. D.; Kozin, D. N.

    2003-06-01

    Main types of photoreceivers used in X-ray digital radiography systems are luminescent screens that transfer the optical image onto charge collection instruments, which require cooling, and semiconductor silicon detectors, which limit the contrast sensitivity. We have developed and produced X-ray radiation detectors of "scintillator-photoreceiving device" (S-PRD) type, which are integrally located on the inverse side of the photodiode (PD). The receiving-converting circuit (RCC) is designed for data conversion into digital form and their input into PC. Software is provided for RCC control and image visualization. Main advantages of these detectors are high industrial resolution (3-5 line pairs per mm), detecting activity up to 20 μm, controlled sensitivity, low weight and small size, imaging low (0.1-0.3 mrad) object dose in real time. In this work, main characteristics of 32-, 64- and 1024-channel detectors of S-PRD type were studied and compared for X-ray sensitivity with S-PD detectors. Images of the tested objects have been obtained. Recommendations are given on the use of different scintillation materials, depending upon the purpose of a digital radiographic system. The detectors operate in a broad energy range of ionizing radiation, hence the size of the controlled object is not limited. The system is sufficiently powerful to ensure frontal (through two walls) observation of pipelines with wall thickness up to 10 cm.

  7. Comparison of Pressures Applied by Digital Tourniquets in the Emergency Department

    PubMed Central

    Lahham, Shadi; Tu, Khoa; Ni, Mickey; Tran, Viet; Lotfipour, Shahram; Anderson, Craig L.; Fox, J Christian

    2011-01-01

    Background: Digital tourniquets used in the emergency department have been scrutinized due to complications associated with their use, including neurovascular injury secondary to excessive tourniquet pressure and digital ischemia caused by a forgotten tourniquet. To minimize these risks, a conspicuous tourniquet that applies the least amount of pressure necessary to maintain hemostasis is recommended. Objective: To evaluate the commonly used tourniquet methods, the Penrose drain, rolled glove, the Tourni-cot and the T-Ring, to determine which applies the lowest pressure while consistently preventing digital perfusion. Methods: We measured the circumference of selected digits of 200 adult males and 200 adult females to determine the adult finger size range. We then measured the pressure applied to four representative finger sizes using a pressure monitor and assessed the ability of each method to prevent digital blood flow with a pulse oximeter. Results: We selected four representative finger sizes: 45mm, 65mm, 70mm, and 85mm to test the different tourniquet methods. All methods consistently prevented digital perfusion. The highest pressure recorded for the Penrose drain was 727 mmHg, the clamped rolled glove 439, the unclamped rolled glove 267, Tourni-cot 246, while the T-Ring had the lowest at 151 mmHg and least variable pressures of all methods. Conclusion: All tested methods provided adequate hemostasis. Only the Tourni-cot and T-Ring provided hemostasis at safe pressures across all digit sizes with the T-Ring having a lower overall average pressure. PMID:21691536

  8. Multivariate statistical analysis software technologies for astrophysical research involving large data bases

    NASA Technical Reports Server (NTRS)

    Djorgovski, S. George

    1994-01-01

    We developed a package to process and analyze the data from the digital version of the Second Palomar Sky Survey. This system, called SKICAT, incorporates the latest in machine learning and expert systems software technology, in order to classify the detected objects objectively and uniformly, and facilitate handling of the enormous data sets from digital sky surveys and other sources. The system provides a powerful, integrated environment for the manipulation and scientific investigation of catalogs from virtually any source. It serves three principal functions: image catalog construction, catalog management, and catalog analysis. Through use of the GID3* Decision Tree artificial induction software, SKICAT automates the process of classifying objects within CCD and digitized plate images. To exploit these catalogs, the system also provides tools to merge them into a large, complete database which may be easily queried and modified when new data or better methods of calibrating or classifying become available. The most innovative feature of SKICAT is the facility it provides to experiment with and apply the latest in machine learning technology to the tasks of catalog construction and analysis. SKICAT provides a unique environment for implementing these tools for any number of future scientific purposes. Initial scientific verification and performance tests have been made using galaxy counts and measurements of galaxy clustering from small subsets of the survey data, and a search for very high redshift quasars. All of the tests were successful, and produced new and interesting scientific results. Attachments to this report give detailed accounts of the technical aspects for multivariate statistical analysis of small and moderate-size data sets, called STATPROG. The package was tested extensively on a number of real scientific applications, and has produced real, published results.

  9. Fused off-axis object illumination direct-to-digital holography with a plurality of illumination sources

    DOEpatents

    Price, Jeffery R.; Bingham, Philip R.

    2005-11-08

    Systems and methods are described for rapid acquisition of fused off-axis illumination direct-to-digital holography. A method of recording a plurality of off-axis object illuminated spatially heterodyne holograms, each of the off-axis object illuminated spatially heterodyne holograms including spatially heterodyne fringes for Fourier analysis, includes digitally recording, with a first illumination source of an interferometer, a first off-axis object illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; and digitally recording, with a second illumination source of the interferometer, a second off-axis object illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis.

  10. A digital flight control system verification laboratory

    NASA Technical Reports Server (NTRS)

    De Feo, P.; Saib, S.

    1982-01-01

    A NASA/FAA program has been established for the verification and validation of digital flight control systems (DFCS), with the primary objective being the development and analysis of automated verification tools. In order to enhance the capabilities, effectiveness, and ease of using the test environment, software verification tools can be applied. Tool design includes a static analyzer, an assertion generator, a symbolic executor, a dynamic analysis instrument, and an automated documentation generator. Static and dynamic tools are integrated with error detection capabilities, resulting in a facility which analyzes a representative testbed of DFCS software. Future investigations will ensue particularly in the areas of increase in the number of software test tools, and a cost effectiveness assessment.

  11. Aeroservoelastic wind-tunnel investigations using the Active Flexible Wing Model: Status and recent accomplishments

    NASA Technical Reports Server (NTRS)

    Noll, Thomas E.; Perry, Boyd, III; Tiffany, Sherwood H.; Cole, Stanley R.; Buttrill, Carey S.; Adams, William M., Jr.; Houck, Jacob A.; Srinathkumar, S.; Mukhopadhyay, Vivek; Pototzky, Anthony S.

    1989-01-01

    The status of the joint NASA/Rockwell Active Flexible Wing Wind-Tunnel Test Program is described. The objectives are to develop and validate the analysis, design, and test methodologies required to apply multifunction active control technology for improving aircraft performance and stability. Major tasks include designing digital multi-input/multi-output flutter-suppression and rolling-maneuver-load alleviation concepts for a flexible full-span wind-tunnel model, obtaining an experimental data base for the basic model and each control concept and providing comparisons between experimental and analytical results to validate the methodologies. The opportunity is provided to improve real-time simulation techniques and to gain practical experience with digital control law implementation procedures.

  12. Representation of the Physiological Factors Contributing to Postflight Changes in Functional Performance Using Motion Analysis Software

    NASA Technical Reports Server (NTRS)

    Parks, Kelsey

    2010-01-01

    Astronauts experience changes in multiple physiological systems due to exposure to the microgravity conditions of space flight. To understand how changes in physiological function influence functional performance, a testing procedure has been developed that evaluates both astronaut postflight functional performance and related physiological changes. Astronauts complete seven functional and physiological tests. The objective of this project is to use motion tracking and digitizing software to visually display the postflight decrement in the functional performance of the astronauts. The motion analysis software will be used to digitize astronaut data videos into stick figure videos to represent the astronauts as they perform the Functional Tasks Tests. This project will benefit NASA by allowing NASA scientists to present data of their neurological studies without revealing the identities of the astronauts.

  13. Recording multiple spatially-heterodyned direct to digital holograms in one digital image

    DOEpatents

    Hanson, Gregory R [Clinton, TN; Bingham, Philip R [Knoxville, TN

    2008-03-25

    Systems and methods are described for recording multiple spatially-heterodyned direct to digital holograms in one digital image. A method includes digitally recording, at a first reference beam-object beam angle, a first spatially-heterodyned hologram including spatial heterodyne fringes for Fourier analysis; Fourier analyzing the recorded first spatially-heterodyned hologram by shifting a first original origin of the recorded first spatially-heterodyned hologram to sit on top of a first spatial-heterodyne carrier frequency defined by the first reference beam-object beam angle; digitally recording, at a second reference beam-object beam angle, a second spatially-heterodyned hologram including spatial heterodyne fringes for Fourier analysis; Fourier analyzing the recorded second spatially-heterodyned hologram by shifting a second original origin of the recorded second spatially-heterodyned hologram to sit on top of a second spatial-heterodyne carrier frequency defined by the second reference beam-object beam angle; applying a first digital filter to cut off signals around the first original origin and define a first result; performing a first inverse Fourier transform on the first result; applying a second digital filter to cut off signals around the second original origin and define a second result; and performing a second inverse Fourier transform on the second result, wherein the first reference beam-object beam angle is not equal to the second reference beam-object beam angle and a single digital image includes both the first spatially-heterodyned hologram and the second spatially-heterodyned hologram.

  14. Effect of geometrical features various objects on the data quality obtained with measured by TLS

    NASA Astrophysics Data System (ADS)

    Pawłowicz, J. A.

    2017-08-01

    Collecting data on different building structures using Terrestrial Laser Scanning (TLS) has become in recent years a very popular due to minimize the time required to complete the task as compared to traditional methods. Technical parameters of 3D scanning devices (digitizers) are increasingly being improved, and the accuracy of the data collected allows you to play not only the geometry of an existing object in a digital image, but also enables the assessment of his condition. This is possible thanks to the digitalization of existing objects e.g., a 3D laser scanner, with which is obtained a digital data base is presented in the form of a cloud of points and by using reverse engineering. Measurements using laser scanners depends to a large extent, on the quality of the returning beam reflected from the target surface, towards the receiver. High impact on the strength and quality of the beam returning to the geometric features of the object. These properties may contribute to the emergence of some, sometimes even serious errors during scanning of various shapes. The study defined the effect of the laser beam distortion during the measurement objects with the same material but with different geometrical features on their three-dimensional imaging obtained from measurements made using TLS. We present the problem of data quality, dependent on the deflection of the beam intensity and shape of the object selected examples. The knowledge of these problems allows to obtain valuable data necessary for the implementation of digitization and the visualization of virtually any building structure made of any materials. The studies has been proven that the increase in the density of scanning does not affect the values of mean square error. The increase in the angle of incidence of the beam onto a flat surface, however, causes a decrease in the intensity of scattered radiation that reaches the receiver. The article presents an analysis of the laser beam reflected from broken at different angles surface. Scan quality was assessed using check the density of the number of points on the test object’s surface.

  15. Differential temperature stress measurement employing array sensor with local offset

    NASA Technical Reports Server (NTRS)

    Lesniak, Jon R. (Inventor)

    1993-01-01

    The instrument has a focal plane array of infrared sensors of the integrating type such as a multiplexed device in which a charge is built up on a capacitor which is proportional to the total number of photons which that sensor is exposed to between read-out cycles. The infrared sensors of the array are manufactured as part of an overall array which is part of a micro-electronic device. The sensor achieves greater sensitivity by applying a local offset to the output of each sensor before it is converted into a digital word. The offset which is applied to each sensor will typically be the sensor's average value so that the digital signal which is periodically read from each sensor of the array corresponds to the portion of the signal which is varying in time. With proper synchronization between the cyclical loading of the test object and the frame rate of the infrared array the output of the A/D converted signal will correspond to the stress field induced temperature variations. A digital lock-in operation may be performed on the output of each sensor in the array. This results in a test instrument which can rapidly form a precise image of the thermoelastic stresses in an object.

  16. Leap Frog Digital Sensors and Definition, Integration & Testing FY 2003 Annual Report

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Meitzler, Wayne D.; Ouderkirk, Steven J.; Shoemaker, Steven V.

    2003-12-31

    The objective of Leap Frog is to develop a comprehensive security tool that is transparent to the user community and more effective than current methods for preventing and detecting security compromises of critical physical and digital assets. Current security tools intrude on the people that interact with these critical assets by requiring them to perform additional functions or having additional visible sensors. Leap Frog takes security to the next level by being more effective and reducing the adverse impact on the people interacting with protected assets.

  17. A direct-view customer-oriented digital holographic camera

    NASA Astrophysics Data System (ADS)

    Besaga, Vira R.; Gerhardt, Nils C.; Maksimyak, Peter P.; Hofmann, Martin R.

    2018-01-01

    In this paper, we propose a direct-view digital holographic camera system consisting mostly of customer-oriented components. The camera system is based on standard photographic units such as camera sensor and objective and is adapted to operate under off-axis external white-light illumination. The common-path geometry of the holographic module of the system ensures direct-view operation. The system can operate in both self-reference and self-interference modes. As a proof of system operability, we present reconstructed amplitude and phase information of a test sample.

  18. Digital image profilers for detecting faint sources which have bright companions, phase 2

    NASA Technical Reports Server (NTRS)

    Morris, Elena; Flint, Graham

    1991-01-01

    A breadboard image profiling system developed for the first phase of this project demonstrated the potential for detecting extremely faint optical sources in the presence of light companions. Experimental data derived from laboratory testing of the device supports the theory that image profilers of this type may approach the theoretical limit imposed by photon statistics. The objective of Phase 2 of this program is the development of a ground-based multichannel image profiling system capable of detecting faint stellar objects slightly displaced from brighter stars. We have finalized the multichannel image profiling system and attempted three field tests.

  19. Content-based fused off-axis object illumination direct-to-digital holography

    DOEpatents

    Price, Jeffery R.

    2006-05-02

    Systems and methods are described for content-based fused off-axis illumination direct-to-digital holography. A method includes calculating an illumination angle with respect to an optical axis defined by a focusing lens as a function of data representing a Fourier analyzed spatially heterodyne hologram; reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object the object beam incident upon the object at the illumination angle; focusing the reference beam and the object beam at a focal plane of a digital recorder to from the content-based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; and digitally recording the content based off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis.

  20. Bottom-up influences of voice continuity in focusing selective auditory attention

    PubMed Central

    Bressler, Scott; Masud, Salwa; Bharadwaj, Hari; Shinn-Cunningham, Barbara

    2015-01-01

    Selective auditory attention causes a relative enhancement of the neural representation of important information and suppression of the neural representation of distracting sound, which enables a listener to analyze and interpret information of interest. Some studies suggest that in both vision and in audition, the “unit” on which attention operates is an object: an estimate of the information coming from a particular external source out in the world. In this view, which object ends up in the attentional foreground depends on the interplay of top-down, volitional attention and stimulus-driven, involuntary attention. Here, we test the idea that auditory attention is object based by exploring whether continuity of a non-spatial feature (talker identity, a feature that helps acoustic elements bind into one perceptual object) also influences selective attention performance. In Experiment 1, we show that perceptual continuity of target talker voice helps listeners report a sequence of spoken target digits embedded in competing reversed digits spoken by different talkers. In Experiment 2, we provide evidence that this benefit of voice continuity is obligatory and automatic, as if voice continuity biases listeners by making it easier to focus on a subsequent target digit when it is perceptually linked to what was already in the attentional foreground. Our results support the idea that feature continuity enhances streaming automatically, thereby influencing the dynamic processes that allow listeners to successfully attend to objects through time in the cacophony that assails our ears in many everyday settings. PMID:24633644

  1. Bottom-up influences of voice continuity in focusing selective auditory attention.

    PubMed

    Bressler, Scott; Masud, Salwa; Bharadwaj, Hari; Shinn-Cunningham, Barbara

    2014-01-01

    Selective auditory attention causes a relative enhancement of the neural representation of important information and suppression of the neural representation of distracting sound, which enables a listener to analyze and interpret information of interest. Some studies suggest that in both vision and in audition, the "unit" on which attention operates is an object: an estimate of the information coming from a particular external source out in the world. In this view, which object ends up in the attentional foreground depends on the interplay of top-down, volitional attention and stimulus-driven, involuntary attention. Here, we test the idea that auditory attention is object based by exploring whether continuity of a non-spatial feature (talker identity, a feature that helps acoustic elements bind into one perceptual object) also influences selective attention performance. In Experiment 1, we show that perceptual continuity of target talker voice helps listeners report a sequence of spoken target digits embedded in competing reversed digits spoken by different talkers. In Experiment 2, we provide evidence that this benefit of voice continuity is obligatory and automatic, as if voice continuity biases listeners by making it easier to focus on a subsequent target digit when it is perceptually linked to what was already in the attentional foreground. Our results support the idea that feature continuity enhances streaming automatically, thereby influencing the dynamic processes that allow listeners to successfully attend to objects through time in the cacophony that assails our ears in many everyday settings.

  2. A Survey of Complex Object Technologies for Digital Libraries

    NASA Technical Reports Server (NTRS)

    Nelson, Michael L.; Argue, Brad; Efron, Miles; Denn, Sheila; Pattuelli, Maria Cristina

    2001-01-01

    Many early web-based digital libraries (DLs) had implicit assumptions reflected in their architecture that the unit of focus in the DL (frequently "reports" or "e-prints") would only be manifested in a single, or at most a few, common file formats such as PDF or PostScript. DLs have now matured to the point where their contents are commonly no longer simple files. Complex objects in DLs have emerged from in response to various requirements, including: simple aggregation of formats and supporting files, bundling additional information to aid digital preservation, creating opaque digital objects for e-commerce applications, and the incorporation of dynamic services with the traditional data files. We examine a representative (but not necessarily exhaustive) number of current and recent historical web-based complex object technologies and projects that are applicable to DLs: Aurora, Buckets, ComMentor, Cryptolopes, Digibox, Document Management Alliance, FEDORA, Kahn-Wilensky Framework Digital Objects, Metadata Encoding & Transmission Standard, Multivalent Documents, Open eBooks, VERS Encapsulated Objects, and the Warwick Framework.

  3. Comparison of different phantoms used in digital diagnostic imaging

    NASA Astrophysics Data System (ADS)

    Bor, Dogan; Unal, Elif; Uslu, Anil

    2015-09-01

    The organs of extremity, chest, skull and lumbar were physically simulated using uniform PMMA slabs with different thicknesses alone and using these slabs together with aluminum plates and air gaps (ANSI Phantoms). The variation of entrance surface air kerma and scatter fraction with X-ray beam qualities was investigated for these phantoms and the results were compared with those measured from anthropomorphic phantoms. A flat panel digital radiographic system was used for all the experiments. Considerable variations of entrance surface air kermas were found for the same organs of different designs, and highest doses were measured for the PMMA slabs. A low contrast test tool and a contrast detail test object (CDRAD) were used together with each organ simulation of PMMA slabs and ANSI phantoms in order to test the clinical image qualities. Digital images of these phantom combinations and anthropomorphic phantoms were acquired in raw and clinically processed formats. Variation of image quality with kVp and post processing was evaluated using the numerical metrics of these test tools and measured contrast values from the anthropomorphic phantoms. Our results indicated that design of some phantoms may not be efficient enough to reveal the expected performance of the post processing algorithms.

  4. Software for Guidance and Control: Guidance and Control Panel Symposium (52nd) Held in Helexpo, Thessaloniki, Greece on 7-10 May 1991 (Les Logiciels de Guidage et de Pilotage)

    DTIC Science & Technology

    1991-09-01

    in frack . Lists, Essential Model Objects, Implamentational Model Because each object in the model is tied to the Objects, Test specifications, etc...structure. hydraulic and even human components, it w. so hamediately Clear now the softwar techeipes could be adapted. Moreover. It was alon felt aeomWto...would be the implementation is anticipated as an analogue, digital, case when one of the monitoring tolerances within the system mechanical, hydraulic

  5. Endoscopic pulsed digital holography for 3D measurements

    NASA Astrophysics Data System (ADS)

    Saucedo, A. Tonatiuh; Mendoza Santoyo, Fernando; de La Torre-Ibarra, Manuel; Pedrini, Giancarlo; Osten, Wolfgang

    2006-02-01

    A rigid endoscope and three different object illumination source positions are used in pulsed digital holography to measure the three orthogonal displacement components from hidden areas of a harmonically vibrating metallic cylinder. In order to obtain simultaneous 3D information from the optical set up, it is necessary to match the optical paths of each of the reference object beam pairs, but to incoherently mismatch the three reference object beam pairs, such that three pulsed digital holograms are incoherently recorded within a single frame of the CCD sensor. The phase difference is obtained using the Fourier method and by subtracting two digital holograms captured for two different object positions.

  6. A Spectrum of Interoperability: The Site for Science Prototype for the NSDL; Re-Inventing the Wheel? Standards, Interoperability and Digital Cultural Content; Preservation Risk Management for Web Resources: Virtual Remote Control in Cornell's Project Prism; Safekeeping: A Cooperative Approach to Building a Digital Preservation Resource; Object Persistence and Availability in Digital Libraries; Illinois Digital Cultural Heritage Community-Collaborative Interactions among Libraries, Museums and Elementary Schools.

    ERIC Educational Resources Information Center

    Arms, William Y.; Hillmann, Diane; Lagoze, Carl; Krafft, Dean; Marisa, Richard; Saylor, John; Terizzi, Carol; Van de Sompel, Herbert; Gill, Tony; Miller, Paul; Kenney, Anne R.; McGovern, Nancy Y.; Botticelli, Peter; Entlich, Richard; Payette, Sandra; Berthon, Hilary; Thomas, Susan; Webb, Colin; Nelson, Michael L.; Allen, B. Danette; Bennett, Nuala A.; Sandore, Beth; Pianfetti, Evangeline S.

    2002-01-01

    Discusses digital libraries, including interoperability, metadata, and international standards; Web resource preservation efforts at Cornell University; digital preservation at the National Library of Australia; object persistence and availability; collaboration among libraries, museums and elementary schools; Asian digital libraries; and a Web…

  7. Application of Phase Shifting Projection Moire on Solid Regular Figures and Plant Organs Three Dimensional Digital Model Generation

    NASA Astrophysics Data System (ADS)

    Lino, A. C. L.; Dal Fabbro, I. M.

    2008-04-01

    The conception of a tridimensional digital model of solid figures and plant organs started from topographic survey of virtual surfaces [1], followed by topographic survey of solid figures [2], fruit surface survey [3] and finally the generation of a 3D digital model [4] as presented by [1]. In this research work, i.e. step number [4] tested objects included cylinders, cubes, spheres and fruits. A Ronchi grid named G1 was generated in a PC, from which other grids referred as G2, G3, and G4 were set out of phase by 1/4, 1/2 and 3/4 of period from G1. Grid G1 was then projected onto the samples surface. Projected grid was named Gd. The difference between Gd and G1 followed by filtration generated de moiré fringes M1 and so on, obtaining the fringes M2, M3 and M4 from Gd. Fringes are out of phase one from each other by 1/4 of period, which were processed by the Rising Sun Moiré software to produce packed phase and further on, the unpacked fringes. Tested object was placed on a goniometer and rotate to generate four surfaces topography. These four surveyed surfaces were assembled by means of a SCILAB software, obtaining a three column matrix, corresponding to the object coordinates xi, also having elevation values and coordinates corrected as well. The work includes conclusions on the reliability of the proposed method as well as the setup simplicity and of low cost.

  8. Ulnar digits contribution to grip strength in patients with thumb carpometacarpal osteoarthritis is less than in normal controls.

    PubMed

    Villafañe, Jorge H; Valdes, Kristin; Angulo-Diaz-Parreño, Santiago; Pillastrini, Paolo; Negrini, Stefano

    2015-06-01

    Grip testing is commonly used as an objective measure of strength in the hand and upper extremity and is frequently used clinically as a proxy measure of function. Increasing knowledge of hand biomechanics, muscle strength, and prehension patterns can provide us with a better understanding of the functional capabilities of the hand. The objectives of this study were to determine the contribution of ulnar digits to overall grip strength in individuals with thumb carpometacarpal (CMC) osteoarthritis (OA). Thirty-seven subjects participated in the study. This group consisted of 19 patients with CMC OA (aged 60-88 years) and 18 healthy subjects (60-88 years). Three hand configurations were used by the subjects during grip testing: use of the entire hand (index, middle, ring, and little fingers) (IMRL); use of the index, middle, and ring fingers (IMR); and use of only the index and middle fingers (IM). Grip strength findings for the two groups found that compared to their healthy counterparts, CMC OA patients had, on average, a strength deficiency of 45.6, 35.5, and 28.8 % in IMRL, IMR, and IM, respectively. The small finger contribution to grip is 14.3 % and the ring and small finger contribute 34 % in subjects with CMC OA. Grip strength decreases as the number of digits contributing decreased in both groups. The ulnar digits contribution to grip strength is greater than one third of total grip strength in subjects with CMC OA. Individuals with CMC OA demonstrate significantly decreased grip strength when compared to their healthy counterparts.

  9. Digital holographic image fusion for a larger size object using compressive sensing

    NASA Astrophysics Data System (ADS)

    Tian, Qiuhong; Yan, Liping; Chen, Benyong; Yao, Jiabao; Zhang, Shihua

    2017-05-01

    Digital holographic imaging fusion for a larger size object using compressive sensing is proposed. In this method, the high frequency component of the digital hologram under discrete wavelet transform is represented sparsely by using compressive sensing so that the data redundancy of digital holographic recording can be resolved validly, the low frequency component is retained totally to ensure the image quality, and multiple reconstructed images with different clear parts corresponding to a laser spot size are fused to realize the high quality reconstructed image of a larger size object. In addition, a filter combing high-pass and low-pass filters is designed to remove the zero-order term from a digital hologram effectively. The digital holographic experimental setup based on off-axis Fresnel digital holography was constructed. The feasible and comparative experiments were carried out. The fused image was evaluated by using the Tamura texture features. The experimental results demonstrated that the proposed method can improve the processing efficiency and visual characteristics of the fused image and enlarge the size of the measured object effectively.

  10. WHOI and SIO (I): Next Steps toward Multi-Institution Archiving of Shipboard and Deep Submergence Vehicle Data

    NASA Astrophysics Data System (ADS)

    Detrick, R. S.; Clark, D.; Gaylord, A.; Goldsmith, R.; Helly, J.; Lemmond, P.; Lerner, S.; Maffei, A.; Miller, S. P.; Norton, C.; Walden, B.

    2005-12-01

    The Scripps Institution of Oceanography (SIO) and the Woods Hole Oceanographic Institution (WHOI) have joined forces with the San Diego Supercomputer Center to build a testbed for multi-institutional archiving of shipboard and deep submergence vehicle data. Support has been provided by the Digital Archiving and Preservation program funded by NSF/CISE and the Library of Congress. In addition to the more than 92,000 objects stored in the SIOExplorer Digital Library, the testbed will provide access to data, photographs, video images and documents from WHOI ships, Alvin submersible and Jason ROV dives, and deep-towed vehicle surveys. An interactive digital library interface will allow combinations of distributed collections to be browsed, metadata inspected, and objects displayed or selected for download. The digital library architecture, and the search and display tools of the SIOExplorer project, are being combined with WHOI tools, such as the Alvin Framegrabber and the Jason Virtual Control Van, that have been designed using WHOI's GeoBrowser to handle the vast volumes of digital video and camera data generated by Alvin, Jason and other deep submergence vehicles. Notions of scalability will be tested, as data volumes range from 3 CDs per cruise to 200 DVDs per cruise. Much of the scalability of this proposal comes from an ability to attach digital library data and metadata acquisition processes to diverse sensor systems. We are able to run an entire digital library from a laptop computer as well as from supercomputer-center-size resources. It can be used, in the field, laboratory or classroom, covering data from acquisition-to-archive using a single coherent methodology. The design is an open architecture, supporting applications through well-defined external interfaces maintained as an open-source effort for community inclusion and enhancement.

  11. STS-48 ESC image of the MODE-01 Fluid Test Article (FTA) on OV-103's middeck

    NASA Technical Reports Server (NTRS)

    1991-01-01

    An electronic still camera (ESC) closeup shows the STS-48 Middeck Zero ('0') Gravity Dynamics Experiment 01 (MODE-01) Fluid Test Article (FTA) attached to an experimental support module (ESM) located in a forward middeck locker onboard the earth-orbiting Discovery, Orbiter Vehicle (OV) 103. The FTA is a 3.1-cm diameter cylindrical sealed Lexan tank. The FTA electromagnetic actuator has excited the test article sinusoidally, which causes the fluid inside the tank to slosh. These slosh forces, along with other data such as acceleration levels of the entire assembly, are measured by the force balance and recorded in digital form on an optical disk for later ground analysis. Crewmembers were testing the ESC as part of Development Test Objective (DTO) 648, Electronic Still Photography. The digital image was stored on a removable hard disk or small optical disk, and could be converted to a format suitable for downlink transmission. The ESC is making its initial appearance on this Space Shutt

  12. The Impact of the Condenser on Cytogenetic Image Quality in Digital Microscope System

    PubMed Central

    Ren, Liqiang; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Xiaodong; Liu, Hong

    2013-01-01

    Background: Optimizing operational parameters of the digital microscope system is an important technique to acquire high quality cytogenetic images and facilitate the process of karyotyping so that the efficiency and accuracy of diagnosis can be improved. OBJECTIVE: This study investigated the impact of the condenser on cytogenetic image quality and system working performance using a prototype digital microscope image scanning system. Methods: Both theoretical analysis and experimental validations through objectively evaluating a resolution test chart and subjectively observing large numbers of specimen were conducted. Results: The results show that the optimal image quality and large depth of field (DOF) are simultaneously obtained when the numerical aperture of condenser is set as 60%–70% of the corresponding objective. Under this condition, more analyzable chromosomes and diagnostic information are obtained. As a result, the system shows higher working stability and less restriction for the implementation of algorithms such as autofocusing especially when the system is designed to achieve high throughput continuous image scanning. Conclusions: Although the above quantitative results were obtained using a specific prototype system under the experimental conditions reported in this paper, the presented evaluation methodologies can provide valuable guidelines for optimizing operational parameters in cytogenetic imaging using the high throughput continuous scanning microscopes in clinical practice. PMID:23676284

  13. Correlation between radiographic analysis of alveolar bone density around dental implant and resonance frequency of dental implant

    NASA Astrophysics Data System (ADS)

    Prawoko, S. S.; Nelwan, L. C.; Odang, R. W.; Kusdhany, L. S.

    2017-08-01

    The histomorphometric test is the gold standard for dental implant stability quantification; however, it is invasive, and therefore, it is inapplicable to clinical patients. Consequently, accurate and objective alternative methods are required. Resonance frequency analysis (RFA) and digital radiographic analysis are noninvasive methods with excellent objectivity and reproducibility. To analyze the correlation between the radiographic analysis of alveolar bone density around a dental implant and the resonance frequency of the dental implant. Digital radiographic images for 35 samples were obtained, and the resonance frequency of the dental implant was acquired using Osstell ISQ immediately after dental implant placement and on third-month follow-up. The alveolar bone density around the dental implant was subsequently analyzed using SIDEXIS-XG software. No significant correlation was reported between the alveolar bone density around the dental implant and the resonance frequency of the dental implant (r = -0.102 at baseline, r = 0.146 at follow-up, p > 0.05). However, the alveolar bone density and resonance frequency showed a significant difference throughout the healing period (p = 0.005 and p = 0.000, respectively). Conclusion: Digital dental radiographs and Osstell ISQ showed excellent objectivity and reproducibility in quantifying dental implant stability. Nonetheless, no significant correlation was observed between the results obtained using these two methods.

  14. Fusion of range camera and photogrammetry: a systematic procedure for improving 3-D models metric accuracy.

    PubMed

    Guidi, G; Beraldin, J A; Ciofi, S; Atzeni, C

    2003-01-01

    The generation of three-dimensional (3-D) digital models produced by optical technologies in some cases involves metric errors. This happens when small high-resolution 3-D images are assembled together in order to model a large object. In some applications, as for example 3-D modeling of Cultural Heritage, the problem of metric accuracy is a major issue and no methods are currently available for enhancing it. The authors present a procedure by which the metric reliability of the 3-D model, obtained through iterative alignments of many range maps, can be guaranteed to a known acceptable level. The goal is the integration of the 3-D range camera system with a close range digital photogrammetry technique. The basic idea is to generate a global coordinate system determined by the digital photogrammetric procedure, measuring the spatial coordinates of optical targets placed around the object to be modeled. Such coordinates, set as reference points, allow the proper rigid motion of few key range maps, including a portion of the targets, in the global reference system defined by photogrammetry. The other 3-D images are normally aligned around these locked images with usual iterative algorithms. Experimental results on an anthropomorphic test object, comparing the conventional and the proposed alignment method, are finally reported.

  15. An object-oriented simulator for 3D digital breast tomosynthesis imaging system.

    PubMed

    Seyyedi, Saeed; Cengiz, Kubra; Kamasak, Mustafa; Yildirim, Isa

    2013-01-01

    Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to reconstruct images from projections. Iterative reconstruction algorithms such as algebraic reconstruction technique (ART) were later developed. Recently, compressed sensing based methods have been proposed in tomosynthesis imaging problem. We have developed an object-oriented simulator for 3D digital breast tomosynthesis (DBT) imaging system using C++ programming language. The simulator is capable of implementing different iterative and compressed sensing based reconstruction methods on 3D digital tomosynthesis data sets and phantom models. A user friendly graphical user interface (GUI) helps users to select and run the desired methods on the designed phantom models or real data sets. The simulator has been tested on a phantom study that simulates breast tomosynthesis imaging problem. Results obtained with various methods including algebraic reconstruction technique (ART) and total variation regularized reconstruction techniques (ART+TV) are presented. Reconstruction results of the methods are compared both visually and quantitatively by evaluating performances of the methods using mean structural similarity (MSSIM) values.

  16. An Object-Oriented Simulator for 3D Digital Breast Tomosynthesis Imaging System

    PubMed Central

    Cengiz, Kubra

    2013-01-01

    Digital breast tomosynthesis (DBT) is an innovative imaging modality that provides 3D reconstructed images of breast to detect the breast cancer. Projections obtained with an X-ray source moving in a limited angle interval are used to reconstruct 3D image of breast. Several reconstruction algorithms are available for DBT imaging. Filtered back projection algorithm has traditionally been used to reconstruct images from projections. Iterative reconstruction algorithms such as algebraic reconstruction technique (ART) were later developed. Recently, compressed sensing based methods have been proposed in tomosynthesis imaging problem. We have developed an object-oriented simulator for 3D digital breast tomosynthesis (DBT) imaging system using C++ programming language. The simulator is capable of implementing different iterative and compressed sensing based reconstruction methods on 3D digital tomosynthesis data sets and phantom models. A user friendly graphical user interface (GUI) helps users to select and run the desired methods on the designed phantom models or real data sets. The simulator has been tested on a phantom study that simulates breast tomosynthesis imaging problem. Results obtained with various methods including algebraic reconstruction technique (ART) and total variation regularized reconstruction techniques (ART+TV) are presented. Reconstruction results of the methods are compared both visually and quantitatively by evaluating performances of the methods using mean structural similarity (MSSIM) values. PMID:24371468

  17. Strike Up the Score: Deriving Searchable and Playable Digital Formats from Sheet Music; Smart Objects and Open Archives; Building the Archives of the Future: Advanced in Preserving Electronic Records at the National Archives and Records Administration; From the Digitized to the Digital Library.

    ERIC Educational Resources Information Center

    Choudhury, G. Sayeed; DiLauro, Tim; Droettboom, Michael; Fujinaga, Ichiro; MacMillan, Karl; Nelson, Michael L.; Maly, Kurt; Thibodeau, Kenneth; Thaller, Manfred

    2001-01-01

    These articles describe the experiences of the Johns Hopkins University library in digitizing their collection of sheet music; motivation for buckets, Smart Object, Dumb Archive (SODA) and the Open Archives Initiative (OAI), and initial experiences using them in digital library (DL) testbeds; requirements for archival institutions, the National…

  18. Arc-An OAI Service Provider for Digital Library Federation; Kepler-An OAI Data/Service Provider for the Individual; Information Objects and Rights Management: A Mediation-Based Approach to DRM Interoperability; Automated Name Authority Control and Enhanced Searching in the Levy Collection; Renardus Project Developments and the Wider Digital Library Context.

    ERIC Educational Resources Information Center

    Liu, Xiaoming; Maly, Kurt; Zubair, Mohammad; Nelson, Michael L.; Erickson, John S.; DiLauro, Tim; Choudhury, G. Sayeed; Patton, Mark; Warner, James W.; Brown, Elizabeth W.; Heery, Rachel; Carpenter, Leona; Day, Michael

    2001-01-01

    Includes five articles that discuss the OAI (Open Archive Initiative), an interface between data providers and service providers; information objects and digital rights management interoperability; digitizing library collections, including automated name authority control, metadata, and text searching engines; and building digital library services…

  19. Application of SIR-B data for groundwater exploration in the Arabian shield and sand-drift monitoring in the AN Nafud and Al Jafurah fringe areas, Kingdom of Saudi Arabia

    NASA Technical Reports Server (NTRS)

    Berlin, G. L.; Tarabzouni, M. A.; Munshi, Z. M. N.; Chavez, P. S., Jr.

    1984-01-01

    The primary objectives of the investigation are to determine fully the utility of Shuttle Imaging Radar-B (SIR-B) images for providing valuable surface indicators for ground-water prospecting in the Arabian shield and to identify and assess defining characteristics of sand sheets, sand streaks, and sand dunes in the fringe areas of An Nafud and Al Jafurah. Specific objectives include the determination of the incremental contribution of incidence angle to the total information that can be extracted from SIR-B standard and digitally-enhanced images in the AL Jafurah fringe area; the determination of the incremental contribution of digitally-registered multisensor images; and the development of a groundwater exploration plan for the Ha'il test area in the Arabian Shield.

  20. A new scale for the assessment of conjunctival bulbar redness.

    PubMed

    Macchi, Ilaria; Bunya, Vatinee Y; Massaro-Giordano, Mina; Stone, Richard A; Maguire, Maureen G; Zheng, Yuanjie; Chen, Min; Gee, James; Smith, Eli; Daniel, Ebenezer

    2018-06-05

    Current scales for assessment of bulbar conjunctival redness have limitations for evaluating digital images. We developed a scale suited for evaluating digital images and compared it to the Validated Bulbar Redness (VBR) scale. From a digital image database of 4889 color corrected bulbar conjunctival images, we identified 20 images with varied degrees of redness. These images, ten each of nasal and temporal views, constitute the Digital Bulbar Redness (DBR) scale. The chromaticity of these images was assessed with an established image processing algorithm. Using 100 unique, randomly selected images from the database, three trained, non-physician graders applied the DBR scale and printed VBR scale. Agreement was assessed with weighted Kappa statistics (K w ). The DBR scale scores provide linear increments of 10 from 10-100 when redness is measured objectively with an established image processing algorithm. Exact agreement of all graders was 38% and agreement with no more than a difference of ten units between graders was 91%. K w for agreement between any two graders ranged from 0.57 to 0.73 for the DBR scale and from 0.38 to 0.66 for the VBR scale. The DBR scale allowed direct comparison of digital to digital images, could be used in dim lighting, had both temporal and nasal conjunctival reference images, and permitted viewing reference and test images at the same magnification. The novel DBR scale, with its objective linear chromatic steps, demonstrated improved reproducibility, fewer visualization artifacts and improved ease of use over the VBR scale for assessing conjunctival redness. Copyright © 2018. Published by Elsevier Inc.

  1. Lumbar spine radiography — poor collimation practices after implementation of digital technology

    PubMed Central

    Zetterberg, L G; Espeland, A

    2011-01-01

    Objectives The transition from analogue to digital radiography may have reduced the motivation to perform proper collimation, as digital techniques have made it possible to mask areas irradiated outside the area of diagnostic interest (ADI). We examined the hypothesis that collimation practices have deteriorated since digitalisation. Methods After defining the ADI, we compared the proportion of the irradiated field outside the ADI in 86 digital and 86 analogue frontal lumbar spine radiographs using the Mann–Whitney test. 50 digital images and 50 analogue images were from a Norwegian hospital and the remainder from a Danish hospital. Consecutive digital images were compared with analogue images (from the hospitals' archives) produced in the 4 years prior to digitalisation. Both hospitals' standard radiographic procedures remained unchanged during the study. For digital images, the irradiated field was assessed using non-masked raw-data images. Results The proportion of the irradiated field outside the ADI was larger in digital than in analogue images (mean 61.7% vs 42.4%, p<0.001), and also in a subsample of 39 image pairs that could be matched for patient age (p<0.001). The mean total field size was 46% larger in digital than in analogue images (791 cm2 vs 541 cm2). Conclusion Following the implementation of digital radiography, considerably larger areas were irradiated. This causes unnecessarily high radiation doses to patients. PMID:21606070

  2. New requirements for digital radiographic testing of welds according to ISO standards

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Zscherpel, U.; Ewert, U.; Jechow, M.

    Users of EN 14784-2 (general principles for computed radiography with phosphor imaging plates) reported about difficulties to achieve testing class B in weld testing with imaging plates. One of the reasons is the insufficient consideration of the inherent detector unsharpness (u{sub i}) in the minimum requirements. Digital detectors have a higher inherent unsharpness compared to film, which can even exceed the geometrical unsharpness (u{sub g}) of the typical contact technique. In EN 444 and ISO 5579 (general principles for film radiography) u{sub i} is neglected for the calculation of the minimum source-to-object distance (SOD), because it is small compared tomore » the geometric unsharpness (u{sub g}). Considering u{sub i} for digital detectors results in a new equation for SOD (see ISO/FDIS 17636-2). Therefore, the increase in total image unsharpness requires the compensation by a larger SOD to reduce u{sub g}. This contribution discusses the need for change of the SOD for different setups (detectors, focal spots, etc.) and explains the difference in image quality, achieved on basis of the extended equation of ISO/FDIS 17636-2. Furthermore, the detection of image quality indicators depends on the achieved Contrast-to-Noise ratio (CNR) and total image unsharpness. Both of them are essential parameters, which influence the contrast sensitivity. Additionally, new compensation principles (e.g. compensation of missing spatial resolution by enhanced contrast sensitivity) allow to widen the application range of digital detectors for radiographic weld testing.« less

  3. Digital servo control of random sound fields

    NASA Technical Reports Server (NTRS)

    Nakich, R. B.

    1973-01-01

    It is necessary to place number of sensors at different positions in sound field to determine actual sound intensities to which test object is subjected. It is possible to determine whether specification is being met adequately or exceeded. Since excitation is of random nature, signals are essentially coherent and it is impossible to obtain true average.

  4. Measuring Distances Using Digital Cameras

    ERIC Educational Resources Information Center

    Kendal, Dave

    2007-01-01

    This paper presents a generic method of calculating accurate horizontal and vertical object distances from digital images taken with any digital camera and lens combination, where the object plane is parallel to the image plane or tilted in the vertical plane. This method was developed for a project investigating the size, density and spatial…

  5. Watermarking 3D Objects for Verification

    DTIC Science & Technology

    1999-01-01

    signal (audio/ image /video) pro- cessing and steganography fields, and even newer to the computer graphics community. Inherently, digital watermarking of...quality images , and digital video. The field of digital watermarking is relatively new, and many of its terms have not been well defined. Among the dif...ferent media types, watermarking of 2D still images is comparatively better studied. Inherently, digital water- marking of 3D objects remains a

  6. Scattered light in a DMD based multi-object spectrometer

    NASA Astrophysics Data System (ADS)

    Fourspring, Kenneth D.; Ninkov, Zoran; Kerekes, John P.

    2010-07-01

    The DMD (Digital Micromirror Device) has an important future in both ground and space based multi-object spectrometers. A series of laboratory measurements have been performed to determine the scattered light properties of a DMD. The DMD under test had a 17 μm pitch and 1 μm gap between adjacent mirrors. Prior characterization of this device has focused on its use in DLP (TI Digital Light Processing) projector applications in which a whole pixel is illuminated by a uniform collimated source. The purpose of performing these measurements is to determine the limiting signal to noise ratio when utilizing the DMD as a slit mask in a spectrometer. The DMD pixel was determined to scatter more around the pixel edge and central via, indicating the importance of matching the telescope point spread function to the DMD. Also, the generation of DMD tested here was determined to have a significant mirror curvature. A maximum contrast ratio was determined at several wavelengths. Further measurements are underway on a newer generation DMD device, which has a smaller mirror pitch and likely different scatter characteristics. A previously constructed instrument, RITMOS (RIT Multi-Object Spectrometer) will be used to validate these scatter models and signal to noise ratio predications through imaging a star field.

  7. Flight-testing of the self-repairing flight control system using the F-15 highly integrated digital electronic control flight research facility

    NASA Technical Reports Server (NTRS)

    Stewart, James F.; Shuck, Thomas L.

    1990-01-01

    Flight tests conducted with the self-repairing flight control system (SRFCS) installed on the NASA F-15 highly integrated digital electronic control aircraft are described. The development leading to the current SRFCS configuration is highlighted. Key objectives of the program are outlined: (1) to flight-evaluate a control reconfiguration strategy with three types of control surface failure; (2) to evaluate a cockpit display that will inform the pilot of the maneuvering capacity of the damage aircraft; and (3) to flight-evaluate the onboard expert system maintenance diagnostics process using representative faults set to occur only under maneuvering conditions. Preliminary flight results addressing the operation of the overall system, as well as the individual technologies, are included.

  8. Digital subtraction radiographic analysis of the combination of bioabsorbable membrane and bovine morphogenetic protein pool in human periodontal infrabony defects

    PubMed Central

    GUIMARÃES, Maria do Carmo Machado; PASSANEZI, Euloir; SANT’ANA, Adriana Campos Passanezi; GREGHI, Sebastião Luiz Aguiar; TABA JUNIOR, Mario

    2010-01-01

    Objectives This study assessed the bone density gain and its relationship with the periodontal clinical parameters in a case series of a regenerative therapy procedure. Material and Methods Using a split-mouth study design, 10 pairs of infrabony defects from 15 patients were treated with a pool of bovine bone morphogenetic proteins associated with collagen membrane (test sites) or collagen membrane only (control sites). The periodontal healing was clinically and radiographically monitored for six months. Standardized presurgical and 6-month postoperative radiographs were digitized for digital subtraction analysis, which showed relative bone density gain in both groups of 0.034 ± 0.423 and 0.105 ± 0.423 in the test and control group, respectively (p>0.05). Results As regards the area size of bone density change, the influence of the therapy was detected in 2.5 mm2 in the test group and 2 mm2 in the control group (p>0.05). Additionally, no correlation was observed between the favorable clinical results and the bone density gain measured by digital subtraction radiography (p>0.05). Conclusions The findings of this study suggest that the clinical benefit of the regenerative therapy observed did not come with significant bone density gains. Long-term evaluation may lead to a different conclusions. PMID:20835573

  9. More About The Video Event Trigger

    NASA Technical Reports Server (NTRS)

    Williams, Glenn L.

    1996-01-01

    Report presents additional information about system described in "Video Event Trigger" (LEW-15076). Digital electronic system processes video-image data to generate trigger signal when image shows significant change, such as motion, or appearance, disappearance, change in color, brightness, or dilation of object. Potential uses include monitoring of hallways, parking lots, and other areas during hours when supposed unoccupied, looking for fires, tracking airplanes or other moving objects, identification of missing or defective parts on production lines, and video recording of automobile crash tests.

  10. Multivariate Statistical Analysis Software Technologies for Astrophysical Research Involving Large Data Bases

    NASA Technical Reports Server (NTRS)

    Djorgovski, S. G.

    1994-01-01

    We developed a package to process and analyze the data from the digital version of the Second Palomar Sky Survey. This system, called SKICAT, incorporates the latest in machine learning and expert systems software technology, in order to classify the detected objects objectively and uniformly, and facilitate handling of the enormous data sets from digital sky surveys and other sources. The system provides a powerful, integrated environment for the manipulation and scientific investigation of catalogs from virtually any source. It serves three principal functions: image catalog construction, catalog management, and catalog analysis. Through use of the GID3* Decision Tree artificial induction software, SKICAT automates the process of classifying objects within CCD and digitized plate images. To exploit these catalogs, the system also provides tools to merge them into a large, complex database which may be easily queried and modified when new data or better methods of calibrating or classifying become available. The most innovative feature of SKICAT is the facility it provides to experiment with and apply the latest in machine learning technology to the tasks of catalog construction and analysis. SKICAT provides a unique environment for implementing these tools for any number of future scientific purposes. Initial scientific verification and performance tests have been made using galaxy counts and measurements of galaxy clustering from small subsets of the survey data, and a search for very high redshift quasars. All of the tests were successful and produced new and interesting scientific results. Attachments to this report give detailed accounts of the technical aspects of the SKICAT system, and of some of the scientific results achieved to date. We also developed a user-friendly package for multivariate statistical analysis of small and moderate-size data sets, called STATPROG. The package was tested extensively on a number of real scientific applications and has produced real, published results.

  11. Digital fabrication of multi-material biomedical objects.

    PubMed

    Cheung, H H; Choi, S H

    2009-12-01

    This paper describes a multi-material virtual prototyping (MMVP) system for modelling and digital fabrication of discrete and functionally graded multi-material objects for biomedical applications. The MMVP system consists of a DMMVP module, an FGMVP module and a virtual reality (VR) simulation module. The DMMVP module is used to model discrete multi-material (DMM) objects, while the FGMVP module is for functionally graded multi-material (FGM) objects. The VR simulation module integrates these two modules to perform digital fabrication of multi-material objects, which can be subsequently visualized and analysed in a virtual environment to optimize MMLM processes for fabrication of product prototypes. Using the MMVP system, two biomedical objects, including a DMM human spine and an FGM intervertebral disc spacer are modelled and digitally fabricated for visualization and analysis in a VR environment. These studies show that the MMVP system is a practical tool for modelling, visualization, and subsequent fabrication of biomedical objects of discrete and functionally graded multi-materials for biomedical applications. The system may be adapted to control MMLM machines with appropriate hardware for physical fabrication of biomedical objects.

  12. Storytelling in the digital world: achieving higher-level learning objectives.

    PubMed

    Schwartz, Melissa R

    2012-01-01

    Nursing students are not passive media consumers but instead live in a technology ecosystem where digital is the language they speak. To prepare the next generation of nurses, educators must incorporate multiple technologies to improve higher-order learning. The author discusses the evolution and use of storytelling as part of the digital world and how digital stories can be aligned with Bloom's Taxonomy so that students achieve higher-level learning objectives.

  13. A Prototype Semantic Web-Based Digital Content Exchange for Schools in Singapore

    ERIC Educational Resources Information Center

    Shabajee, Paul; McBride, Brian; Steer, Damian; Reynolds, Dave

    2006-01-01

    Singapore has many large and educationally valuable digital collections and is planning the development of many more. These digital collections contain historical, cultural and scientific multimedia objects, along with learning objects. At present, school teachers and pupils find it hard to locate many of these resources using traditional search…

  14. A Digital Library for Education: The PEN-DOR Project.

    ERIC Educational Resources Information Center

    Fullerton, Karen; Greenberg, Jane; McClure, Maureen; Rasmussen, Edie; Stewart, Darin

    1999-01-01

    Describes Pen-DOR (Pennsylvania Education Network Digital Object Repository), a digital library designed to provide K-12 educators with access to multimedia resources and tools to create new lesson plans and modify existing ones via the World Wide Web. Discusses design problems of a distributed, object-oriented database architecture and describes…

  15. Object-based neglect in number processing

    PubMed Central

    2013-01-01

    Recent evidence suggests that neglect patients seem to have particular problems representing relatively smaller numbers corresponding to the left part of the mental number line. However, while this indicates space-based neglect for representational number space little is known about whether and - if so - how object-based neglect influences number processing. To evaluate influences of object-based neglect in numerical cognition, a group of neglect patients and two control groups had to compare two-digit numbers to an internally represented standard. Conceptualizing two-digit numbers as objects of which the left part (i.e., the tens digit should be specifically neglected) we were able to evaluate object-based neglect for number magnitude processing. Object-based neglect was indicated by a larger unit-decade compatibility effect actually reflecting impaired processing of the leftward tens digits. Additionally, faster processing of within- as compared to between-decade items provided further evidence suggesting particular difficulties in integrating tens and units into the place-value structure of the Arabic number system. In summary, the present study indicates that, in addition to the spatial representation of number magnitude, also the processing of place-value information of multi-digit numbers seems specifically impaired in neglect patients. PMID:23343126

  16. 3D Printing of CT Dataset: Validation of an Open Source and Consumer-Available Workflow.

    PubMed

    Bortolotto, Chandra; Eshja, Esmeralda; Peroni, Caterina; Orlandi, Matteo A; Bizzotto, Nicola; Poggi, Paolo

    2016-02-01

    The broad availability of cheap three-dimensional (3D) printing equipment has raised the need for a thorough analysis on its effects on clinical accuracy. Our aim is to determine whether the accuracy of 3D printing process is affected by the use of a low-budget workflow based on open source software and consumer's commercially available 3D printers. A group of test objects was scanned with a 64-slice computed tomography (CT) in order to build their 3D copies. CT datasets were elaborated using a software chain based on three free and open source software. Objects were printed out with a commercially available 3D printer. Both the 3D copies and the test objects were measured using a digital professional caliper. Overall, the objects' mean absolute difference between test objects and 3D copies is 0.23 mm and the mean relative difference amounts to 0.55 %. Our results demonstrate that the accuracy of 3D printing process remains high despite the use of a low-budget workflow.

  17. New knowledge in determining the astronomical orientation of Incas object in Ollantaytambo, Peru

    NASA Astrophysics Data System (ADS)

    Hanzalová, K.; Klokočník, J.; Kostelecký, J.

    2014-06-01

    This paper deals about astronomical orientation of Incas objects in Ollantaytambo, which is located about 35 km southeast from Machu Picchu, about 40 km northwest from Cusco, and lies in the Urubamba valley. Everybody writing about Ollantaytambo, shoud read Protzen (1993). He devoted his monograph to description and interpretation of that locality. Book of Salazar and Salazar (2005) deals, among others, with the orientation of objects in Ollantaytambo with respect to the cardinal direction. Zawaski and Malville (2007) documented astronomical context of major monuments of nine sites in Peru, including Ollantaytambo. We tested astronomical orientation in these places and confirm or disprove hypothesis about purpose of Incas objects. For assessment orientation of objects we used our measurements and also satellite images on Google Earth and digital elevation model from ASTER. The satellite images used to approximate estimation of astronomical orientation. The digital elevation model is useful in the mountains, where we need the really horizon for a calculation of sunset and sunrise on specific days (solstices), which were for Incas people very important. By Incas is very famous that they worshiped the Sun. According to him they determined when to plant and when to harvest the crop. In this paper we focused on Temple of the Sun, also known the Wall of six monoliths. We tested which astronomical phenomenon is connected with this Temple. First, we tested winter solstice sunrise and the rides of the Pleiades for the epochs 2000, 1500 and 1000 A.D. According with our results the Temple isn't connected neither with winter solstice sunrise nor with the Pleiades. Then we tested also winter solstice sunset. We tried to use the line from an observation point near ruins of the Temple of Sun, to west-north, in direction to sunset. The astronomical azimuth from this point was about 5° less then we need. From this results we found, that is possible to find another observation point. By Salazar and Salazar (2005) we found observation point at the corner (east rectangle) of the pyramid by Pacaritanpu, down by the riverside. There is a line connecting the east rectangular "platform" at the river, going along the Inca road up to vicinity of the Temple of the Sun and then in the direction to the Inca face. Using a digital elevation model we found the astronomical azimuth, which is needed for confirm astronomical orientation of the Temple. So, finally we are able to demonstrate a possibility of the solar-solstice orientation in Ollantaytambo.

  18. Validity and reproducibility of cephalometric measurements obtained from digital photographs of analogue headfilms.

    PubMed

    Grybauskas, Simonas; Balciuniene, Irena; Vetra, Janis

    2007-01-01

    The emerging market of digital cephalographs and computerized cephalometry is overwhelming the need to examine the advantages and drawbacks of manual cephalometry, meanwhile, small offices continue to benefit from the economic efficacy and ease of use of analogue cephalograms. The use of modern cephalometric software requires import of digital cephalograms or digital capture of analogue data: scanning and digital photography. The validity of digital photographs of analogue headfilms rather than original headfilms in clinical practice has not been well established. Digital photography could be a fast and inexpensive method of digital capture of analogue cephalograms for use in digital cephalometry. The objective of this study was to determine the validity and reproducibility of measurements obtained from digital photographs of analogue headfilms in lateral cephalometry. Analogue cephalometric radiographs were performed on 15 human dry skulls. Each of them was traced on acetate paper and photographed three times independently. Acetate tracings and digital photographs were digitized and analyzed in cephalometric software. Linear regression model, paired t-test intergroup analysis and coefficient of repeatability were used to assess validity and reproducibility for 63 angular, linear and derivative measurements. 54 out of 63 measurements were determined to have clinically acceptable reproducibility in the acetate tracing group as well as 46 out of 63 in the digital photography group. The worst reproducibility was determined for measurements dependent on landmarks of incisors and poorly defined outlines, majority of them being angular measurements. Validity was acceptable for all measurements, and although statistically significant differences between methods existed for as many as 15 parameters, they appeared to be clinically insignificant being smaller than 1 unit of measurement. Validity was acceptable for 59 of 63 measurements obtained from digital photographs, substantiating the use of digital photography for headfilm capture and computer-aided cephalometric analysis.

  19. Effect of sway on image fidelity in whole-body digitizing

    NASA Astrophysics Data System (ADS)

    Corner, Brian D.; Hu, Anmin

    1998-03-01

    For 3D digitizers to be useful data collection tools in scientific and human factors engineering applications, the models created from scan data must match the original object very closely. Factors such as ambient light, characteristics of the object's surface, and object movement, among others can affect the quality of the image produced by any 3D digitizing system. Recently, Cyberware has developed a whole body digitizer for collecting data on human size and shape. With a digitizing time of about 15 seconds, the effect subject movement, or sway, on model fidelity is an important issue to be addressed. The effect of sway is best measured by comparing the dimensions of an object of known geometry to the model of the same object captured by the digitizer. Since it is difficult to know the geometry of a human body accurately, it was decided to compare an object of simple geometry to its digitized counterpart. Preliminary analysis showed that a single cardboard tube would provide the best artifact for detecting sway. A tube was attached to the subjects using supports that allowed the cylinder to stand away from the body. The stand-off was necessary to minimize occluded areas. Multiple scans were taken of 1 subject and the cylinder extracted from the images. Comparison of the actual cylinder dimensions to those extracted from the whole body images found the effect of sway to be minimal. This follows earlier findings that anthropometric dimensions extracted from whole body scans are very close to the same dimensions measured using standard manual methods. Recommendations for subject preparation and stabilization are discussed.

  20. 42 CFR 37.42 - Chest radiograph specifications-digital radiography systems.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... resolution, modulation transfer function (MTF), image signal-to-noise and detective quantum efficiency must... Information Object Definitions, sections: Computed Radiography Image Information Object Definition; Digital X...

  1. Technical note on the validation of a semi-automated image analysis software application for estrogen and progesterone receptor detection in breast cancer.

    PubMed

    Krecsák, László; Micsik, Tamás; Kiszler, Gábor; Krenács, Tibor; Szabó, Dániel; Jónás, Viktor; Császár, Gergely; Czuni, László; Gurzó, Péter; Ficsor, Levente; Molnár, Béla

    2011-01-18

    The immunohistochemical detection of estrogen (ER) and progesterone (PR) receptors in breast cancer is routinely used for prognostic and predictive testing. Whole slide digitalization supported by dedicated software tools allows quantization of the image objects (e.g. cell membrane, nuclei) and an unbiased analysis of immunostaining results. Validation studies of image analysis applications for the detection of ER and PR in breast cancer specimens provided strong concordance between the pathologist's manual assessment of slides and scoring performed using different software applications. The effectiveness of two connected semi-automated image analysis software (NuclearQuant v. 1.13 application for Pannoramic™ Viewer v. 1.14) for determination of ER and PR status in formalin-fixed paraffin embedded breast cancer specimens immunostained with the automated Leica Bond Max system was studied. First the detection algorithm was calibrated to the scores provided an independent assessors (pathologist), using selected areas from 38 small digital slides (created from 16 cases) containing a mean number of 195 cells. Each cell was manually marked and scored according to the Allred-system combining frequency and intensity scores. The performance of the calibrated algorithm was tested on 16 cases (14 invasive ductal carcinoma, 2 invasive lobular carcinoma) against the pathologist's manual scoring of digital slides. The detection was calibrated to 87 percent object detection agreement and almost perfect Total Score agreement (Cohen's kappa 0.859, quadratic weighted kappa 0.986) from slight or moderate agreement at the start of the study, using the un-calibrated algorithm. The performance of the application was tested against the pathologist's manual scoring of digital slides on 53 regions of interest of 16 ER and PR slides covering all positivity ranges, and the quadratic weighted kappa provided almost perfect agreement (κ = 0.981) among the two scoring schemes. NuclearQuant v. 1.13 application for Pannoramic™ Viewer v. 1.14 software application proved to be a reliable image analysis tool for pathologists testing ER and PR status in breast cancer.

  2. Linear encoding device

    NASA Technical Reports Server (NTRS)

    Leviton, Douglas B. (Inventor)

    1993-01-01

    A Linear Motion Encoding device for measuring the linear motion of a moving object is disclosed in which a light source is mounted on the moving object and a position sensitive detector such as an array photodetector is mounted on a nearby stationary object. The light source emits a light beam directed towards the array photodetector such that a light spot is created on the array. An analog-to-digital converter, connected to the array photodetector is used for reading the position of the spot on the array photodetector. A microprocessor and memory is connected to the analog-to-digital converter to hold and manipulate data provided by the analog-to-digital converter on the position of the spot and to compute the linear displacement of the moving object based upon the data from the analog-to-digital converter.

  3. Tooth-size discrepancy: A comparison between manual and digital methods

    PubMed Central

    Correia, Gabriele Dória Cabral; Habib, Fernando Antonio Lima; Vogel, Carlos Jorge

    2014-01-01

    Introduction Technological advances in Dentistry have emerged primarily in the area of diagnostic tools. One example is the 3D scanner, which can transform plaster models into three-dimensional digital models. Objective This study aimed to assess the reliability of tooth size-arch length discrepancy analysis measurements performed on three-dimensional digital models, and compare these measurements with those obtained from plaster models. Material and Methods To this end, plaster models of lower dental arches and their corresponding three-dimensional digital models acquired with a 3Shape R700T scanner were used. All of them had lower permanent dentition. Four different tooth size-arch length discrepancy calculations were performed on each model, two of which by manual methods using calipers and brass wire, and two by digital methods using linear measurements and parabolas. Results Data were statistically assessed using Friedman test and no statistically significant differences were found between the two methods (P > 0.05), except for values found by the linear digital method which revealed a slight, non-significant statistical difference. Conclusions Based on the results, it is reasonable to assert that any of these resources used by orthodontists to clinically assess tooth size-arch length discrepancy can be considered reliable. PMID:25279529

  4. Study of pipe thickness loss using a neutron radiography method

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Mohamed, Abdul Aziz; Wahab, Aliff Amiru Bin; Yazid, Hafizal B.

    2014-02-12

    The purpose of this preliminary work is to study for thickness changes in objects using neutron radiography. In doing the project, the technique for the radiography was studied. The experiment was done at NUR-2 facility at TRIGA research reactor in Malaysian Nuclear Agency, Malaysia. Test samples of varying materials were used in this project. The samples were radiographed using direct technique. Radiographic images were recorded using Nitrocellulose film. The films obtained were digitized to processed and analyzed. Digital processing is done on the images using software Isee!. The images were processed to produce better image for analysis. The thickness changesmore » in the image were measured to be compared with real thickness of the objects. From the data collected, percentages difference between measured and real thickness are below than 2%. This is considerably very low variation from original values. Therefore, verifying the neutron radiography technique used in this project.« less

  5. Objective Measurement of Erythema in Psoriasis using Digital Color Photography with Color Calibration

    PubMed Central

    Raina, Abhay; Hennessy, Ricky; Rains, Michael; Allred, James; Hirshburg, Jason M; Diven, Dayna; Markey, Mia K.

    2016-01-01

    Background Traditional metrics for evaluating the severity of psoriasis are subjective, which complicates efforts to measure effective treatments in clinical trials. Methods We collected images of psoriasis plaques and calibrated the coloration of the images according to an included color card. Features were extracted from the images and used to train a linear discriminant analysis classifier with cross-validation to automatically classify the degree of erythema. The results were tested against numerical scores obtained by a panel of dermatologists using a standard rating system. Results Quantitative measures of erythema based on the digital color images showed good agreement with subjective assessment of erythema severity (κ = 0.4203). The color calibration process improved the agreement from κ = 0.2364 to κ = 0.4203. Conclusions We propose a method for the objective measurement of the psoriasis severity parameter of erythema and show that the calibration process improved the results. PMID:26517973

  6. The Speed of Serial Attention Shifts in Visual Search: Evidence from the N2pc Component.

    PubMed

    Grubert, Anna; Eimer, Martin

    2016-02-01

    Finding target objects among distractors in visual search display is often assumed to be based on sequential movements of attention between different objects. However, the speed of such serial attention shifts is still under dispute. We employed a search task that encouraged the successive allocation of attention to two target objects in the same search display and measured N2pc components to determine how fast attention moved between these objects. Each display contained one digit in a known color (fixed-color target) and another digit whose color changed unpredictably across trials (variable-color target) together with two gray distractor digits. Participants' task was to find the fixed-color digit and compare its numerical value with that of the variable-color digit. N2pc components to fixed-color targets preceded N2pc components to variable-color digits, demonstrating that these two targets were indeed selected in a fixed serial order. The N2pc to variable-color digits emerged approximately 60 msec after the N2pc to fixed-color digits, which shows that attention can be reallocated very rapidly between different target objects in the visual field. When search display durations were increased, thereby relaxing the temporal demands on serial selection, the two N2pc components to fixed-color and variable-color targets were elicited within 90 msec of each other. Results demonstrate that sequential shifts of attention between different target locations can operate very rapidly at speeds that are in line with the assumptions of serial selection models of visual search.

  7. Neural Representations of Sensorimotor Memory- and Digit Position-Based Load Force Adjustments Before the Onset of Dexterous Object Manipulation.

    PubMed

    Marneweck, Michelle; Barany, Deborah A; Santello, Marco; Grafton, Scott T

    2018-05-16

    Anticipatory load forces for dexterous object manipulation in humans are modulated based on visual object property cues, sensorimotor memories of previous experiences with the object, and, when digit positioning varies from trial to trial, the integrating of this sensed variability with force modulation. Studies of the neural representations encoding these anticipatory mechanisms have not considered these mechanisms separately from each other or from feedback mechanisms emerging after lift onset. Here, representational similarity analyses of fMRI data were used to identify neural representations of sensorimotor memories and the sensing and integration of digit position. Cortical activity and movement kinematics were measured as 20 human subjects (11 women) minimized tilt of a symmetrically shaped object with a concealed asymmetric center of mass (CoM, left and right sided). This task required generating compensatory torques in opposite directions, which, without helpful visual CoM cues, relied primarily on sensorimotor memories of the same object and CoM. Digit position was constrained or unconstrained, the latter of which required modulating forces beyond what can be recalled from sensorimotor memories to compensate for digit position variability. Ventral premotor (PMv), somatosensory, and cerebellar lobule regions (CrusII, VIIIa) were sensitive to anticipatory behaviors that reflect sensorimotor memory content, as shown by larger voxel pattern differences for unmatched than matched CoM conditions. Cerebellar lobule I-IV, Broca area 44, and PMv showed greater voxel pattern differences for unconstrained than constrained grasping, which suggests their sensitivity to monitor the online coincidence of planned and actual digit positions and correct for a mismatch by force modulation. SIGNIFICANCE STATEMENT To pick up a water glass without slipping, tipping, or spilling requires anticipatory planning of fingertip load forces before the lift commences. This anticipation relies on object visual properties (e.g., mass/mass distribution), sensorimotor memories built from previous experiences (especially when object properties cannot be inferred visually), and online sensing of where the digits are positioned. There is limited understanding of how the brain represents each of these anticipatory mechanisms. We used fMRI measures of regional brain patterns and digit position kinematics before lift onset of an object with nonsalient visual cues specifically to isolate sensorimotor memories and integration of sensed digit position with force modulation. In doing so, we localized neural representations encoding these anticipatory mechanisms for dexterous object manipulation. Copyright © 2018 the authors 0270-6474/18/384724-14$15.00/0.

  8. Full-color digitized holography for large-scale holographic 3D imaging of physical and nonphysical objects.

    PubMed

    Matsushima, Kyoji; Sonobe, Noriaki

    2018-01-01

    Digitized holography techniques are used to reconstruct three-dimensional (3D) images of physical objects using large-scale computer-generated holograms (CGHs). The object field is captured at three wavelengths over a wide area at high densities. Synthetic aperture techniques using single sensors are used for image capture in phase-shifting digital holography. The captured object field is incorporated into a virtual 3D scene that includes nonphysical objects, e.g., polygon-meshed CG models. The synthetic object field is optically reconstructed as a large-scale full-color CGH using red-green-blue color filters. The CGH has a wide full-parallax viewing zone and reconstructs a deep 3D scene with natural motion parallax.

  9. Apparatus for direct-to-digital spatially-heterodyned holography

    DOEpatents

    Thomas, Clarence E.; Hanson, Gregory R.

    2006-12-12

    An apparatus operable to record a spatially low-frequency heterodyne hologram including spatially heterodyne fringes for Fourier analysis includes: a laser; a beamsplitter optically coupled to the laser; an object optically coupled to the beamsplitter; a focusing lens optically coupled to both the beamsplitter and the object; a digital recorder optically coupled to the focusing lens; and a computer that performs a Fourier transform, applies a digital filter, and performs an inverse Fourier transform. A reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form a spatially low-frequency heterodyne hologram including spatially heterodyne fringes for Fourier analysis which is recorded by the digital recorder, and the computer transforms the recorded spatially low-frequency heterodyne hologram including spatially heterodyne fringes and shifts axes in Fourier space to sit on top of a heterodyne carrier frequency defined by an angle between the reference beam and the object beam and cuts off signals around an original origin before performing the inverse Fourier transform.

  10. Acquisition and replay systems for direct-to-digital holography and holovision

    DOEpatents

    Thomas, Clarence E.; Hanson, Gregory R.

    2003-02-25

    Improvements to the acquisition and replay systems for direct-to-digital holography and holovision are described. A method of recording an off-axis hologram includes: splitting a laser beam into an object beam and a reference beam; reflecting the reference beam from a reference beam mirror; reflecting the object beam from an illumination beamsplitter; passing the object beam through an objective lens; reflecting the object beam from an object; focusing the reference beam and the object beam at a focal plane of a digital recorder to form an off-axis hologram; digitally recording the off-axis hologram; and transforming the off-axis hologram in accordance with a Fourier transform to obtain a set of results. A method of writing an off-axis hologram includes: passing a laser beam through a spatial light modulator; and focusing the laser beam at a focal plane of a photorefractive crystal to impose a holographic diffraction grating pattern on the photorefractive crystal. A method of replaying an off-axis hologram includes: illuminating a photorefractive crystal having a holographic diffraction grating with a replay beam.

  11. In-Vacuum Photogrammetry of a 10-Meter Solar Sail

    NASA Technical Reports Server (NTRS)

    Meyer, Chris G.; Jones, Thomas W.; Lunsford, Charles B.; Pappa, Richard S.

    2005-01-01

    In July 2004, a 10-meter solar sail structure developed by L Garde, Inc. was tested in vacuum at the NASA Glenn 30-meter Plum Brook Space Power Facility in Sandusky, Ohio. The three main objections of the test were to demonstrate unattended deployment from a stowed configuration, to measure the deployed shape of the sail at both ambient and cryogenic room temperatures, and to measure the deployed structural dynamic characteristics (vibration modes). This paper summarizes the work conducted to fulfill the second test objective. The deployed shape was measured photogrammetrically in vacuum conditions with four 2-megapixel digital video cameras contained in custom made pressurized canisters. The canisters included high-intensity LED ring lights to illuminate a grid of retroreflective targets distributed on the solar sail. The test results closely matched pre-test photogrammetry numerical simulations and compare well with ABAQUS finite-element model predictions.

  12. Application of digital mapping technology to the display of hydrologic information; a proof-of-concept test in the Fox-Wolf River Basin, Wisconsin

    USGS Publications Warehouse

    Moore, G.K.; Baten, L.G.; Allord, G.J.; Robinove, C.J.

    1983-01-01

    The Fox-Wolf River basin in east-central Wisconsin was selected to test concepts for a water-resources information system using digital mapping technology. This basin of 16,800 sq km is typical of many areas in the country. Fifty digital data sets were included in the Fox-Wolf information system. Many data sets were digitized from 1:500,000 scale maps and overlays. Some thematic data were acquired from WATSTORE and other digital data files. All data were geometrically transformed into a Lambert Conformal Conic map projection and converted to a raster format with a 1-km resolution. The result of this preliminary processing was a group of spatially registered, digital data sets in map form. Parameter evaluation, areal stratification, data merging, and data integration were used to achieve the processing objectives and to obtain analysis results for the Fox-Wolf basin. Parameter evaluation includes the visual interpretation of single data sets and digital processing to obtain new derived data sets. In the areal stratification stage, masks were used to extract from one data set all features that are within a selected area on another data set. Most processing results were obtained by data merging. Merging is the combination of two or more data sets into a composite product, in which the contribution of each original data set is apparent and can be extracted from the composite. One processing result was also obtained by data integration. Integration is the combination of two or more data sets into a single new product, from which the original data cannot be separated or calculated. (USGS)

  13. Differences in standing and sitting postures of youth with idiopathic scoliosis from quantitative analysis of digital photographs.

    PubMed

    Fortin, Carole; Ehrmann Feldman, Debbie; Cheriet, Farida; Labelle, Hubert

    2013-08-01

    The objective of this study was to explore whether differences in standing and sitting postures of youth with idiopathic scoliosis could be detected from quantitative analysis of digital photographs. Standing and sitting postures of 50 participants aged 10-20-years-old with idiopathic scoliosis (Cobb angle: 15° to 60°) were assessed from digital photographs using a posture evaluation software program. Based on the XY coordinates of markers, 13 angular and linear posture indices were calculated in both positions. Paired t-tests were used to compare values of standing and sitting posture indices. Significant differences between standing and sitting positions (p < 0.05) were found for head protraction, shoulder elevation, scapula asymmetry, trunk list, scoliosis angle, waist angles, and frontal and sagittal plane pelvic tilt. Quantitative analysis of digital photographs is a clinically feasible method to measure standing and sitting postures among youth with scoliosis and to assist in decisions on therapeutic interventions.

  14. Image-Enhancement Aid For The Partially Sighted

    NASA Technical Reports Server (NTRS)

    Lawton, T. A.; Gennery, D. B.

    1989-01-01

    Digital filtering enhances ability to read and to recognize objects. Possible to construct portable vision aid by combining miniature video equipment to observe scene and display images with very-large-scale integrated circuits to implement real-time digital image-data processing. Afflicted observer views scene through magnifier to shift spatial frequencies downward and thereby improves perceived image. However, less magnification needed, larger the scene observed. Thus, one measure of effectiveness of new system is amount of magnification required with and without it. In series of tests, found 27 to 70 percent more magnification needed for afflicted observers to recognize unfiltered words than to recognize filtered words.

  15. Test-re-test reliability and inter-rater reliability of a digital pelvic inclinometer in young, healthy males and females.

    PubMed

    Beardsley, Chris; Egerton, Tim; Skinner, Brendon

    2016-01-01

    Objective. The purpose of this study was to investigate the reliability of a digital pelvic inclinometer (DPI) for measuring sagittal plane pelvic tilt in 18 young, healthy males and females. Method. The inter-rater reliability and test-re-test reliabilities of the DPI for measuring pelvic tilt in standing on both the right and left sides of the pelvis were measured by two raters carrying out two rating sessions of the same subjects, three weeks apart. Results. For measuring pelvic tilt, inter-rater reliability was designated as good on both sides (ICC = 0.81-0.88), test-re-test reliability within a single rating session was designated as good on both sides (ICC = 0.88-0.95), and test-re-test reliability between two rating sessions was designated as moderate on the left side (ICC = 0.65) and good on the right side (ICC = 0.85). Conclusion. Inter-rater reliability and test-re-test reliability within a single rating session of the DPI in measuring pelvic tilt were both good, while test-re-test reliability between rating sessions was moderate-to-good. Caution is required regarding the interpretation of the test-re-test reliability within a single rating session, as the raters were not blinded. Further research is required to establish validity.

  16. Results of data base management system parameterized performance testing related to GSFC scientific applications

    NASA Technical Reports Server (NTRS)

    Carchedi, C. H.; Gough, T. L.; Huston, H. A.

    1983-01-01

    The results of a variety of tests designed to demonstrate and evaluate the performance of several commercially available data base management system (DBMS) products compatible with the Digital Equipment Corporation VAX 11/780 computer system are summarized. The tests were performed on the INGRES, ORACLE, and SEED DBMS products employing applications that were similar to scientific applications under development by NASA. The objectives of this testing included determining the strength and weaknesses of the candidate systems, performance trade-offs of various design alternatives and the impact of some installation and environmental (computer related) influences.

  17. Direct-to-digital holography and holovision

    DOEpatents

    Thomas, Clarence E.; Baylor, Larry R.; Hanson, Gregory R.; Rasmussen, David A.; Voelkl, Edgar; Castracane, James; Simkulet, Michelle; Clow, Lawrence

    2000-01-01

    Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made.

  18. Virtual mask digital electron beam lithography

    DOEpatents

    Baylor, L.R.; Thomas, C.E.; Voelkl, E.; Moore, J.A.; Simpson, M.L.; Paulus, M.J.

    1999-04-06

    Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made. 5 figs.

  19. Virtual mask digital electron beam lithography

    DOEpatents

    Baylor, Larry R.; Thomas, Clarence E.; Voelkl, Edgar; Moore, James A.; Simpson, Michael L.; Paulus, Michael J.

    1999-01-01

    Systems and methods for direct-to-digital holography are described. An apparatus includes a laser; a beamsplitter optically coupled to the laser; a reference beam mirror optically coupled to the beamsplitter; an object optically coupled to the beamsplitter, a focusing lens optically coupled to both the reference beam mirror and the object; and a digital recorder optically coupled to the focusing lens. A reference beam is incident upon the reference beam mirror at a non-normal angle, and the reference beam and an object beam are focused by the focusing lens at a focal plane of the digital recorder to form an image. The systems and methods provide advantages in that computer assisted holographic measurements can be made.

  20. Automatic segmentation of bones from digital hand radiographs

    NASA Astrophysics Data System (ADS)

    Liu, Brent J.; Taira, Ricky K.; Shim, Hyeonjoon; Keaton, Patricia

    1995-05-01

    The purpose of this paper is to develop a robust and accurate method that automatically segments phalangeal and epiphyseal bones from digital pediatric hand radiographs exhibiting various stages of growth. The algorithm uses an object-oriented approach comprising several stages beginning with the most general objects to be segmented, such as the outline of the hand from background, and proceeding in a succession of stages to the most specific object, such as a specific phalangeal bone from a digit of the hand. Each stage carries custom operators unique to the needs of that specific stage which will aid in more accurate results. The method is further aided by a knowledge base where all model contours and other information such as age, race, and sex, are stored. Shape models, 1-D wrist profiles, as well as an interpretation tree are used to map model and data contour segments. Shape analysis is performed using an arc-length orientation transform. The method is tested on close to 340 phalangeal and epiphyseal objects to be segmented from 17 cases of pediatric hand images obtained from our clinical PACS. Patient age ranges from 2 - 16 years. A pediatric radiologist preliminarily assessed the results of the object contours and were found to be accurate to within 95% for cases with non-fused bones and to within 85% for cases with fused bones. With accurate and robust results, the method can be applied toward areas such as the determination of bone age, the development of a normal hand atlas, and the characterization of many congenital and acquired growth diseases. Furthermore, this method's architecture can be applied to other image segmentation problems.

  1. An Investigation into Digital Media: Characteristics of Learning Objects Which K-12 Teachers Determine Meet Their Instructional Needs

    ERIC Educational Resources Information Center

    Guthrie, Patricia Ann

    2010-01-01

    In recent years, learning objects have emerged as an instructional tool for teachers. Digital libraries and collections provide teachers with free or fee-base access to a variety of learning objects from photos and famous speeches to Flash animations and interactive Java Applets. Learning objects offer opportunities for students to interact with…

  2. Proposal of a Framework for Internet Based Licensing of Learning Objects

    ERIC Educational Resources Information Center

    Santos, Osvaldo A.; Ramos, Fernando M. S.

    2004-01-01

    This paper presents a proposal of a framework whose main objective is to manage the delivery and rendering of learning objects in a digital rights controlled environment. The framework is based on a digital licensing scheme that requires each learning object to have the proper license in order to be rendered by a trusted player. A conceptual model…

  3. Simulation and Digitization of a Gas Electron Multiplier Detector Using Geant4 and an Object-Oriented Digitization Program

    NASA Astrophysics Data System (ADS)

    McMullen, Timothy; Liyanage, Nilanga; Xiong, Weizhi; Zhao, Zhiwen

    2017-01-01

    Our research has focused on simulating the response of a Gas Electron Multiplier (GEM) detector using computational methods. GEM detectors provide a cost effective solution for radiation detection in high rate environments. A detailed simulation of GEM detector response to radiation is essential for the successful adaption of these detectors to different applications. Using Geant4 Monte Carlo (GEMC), a wrapper around Geant4 which has been successfully used to simulate the Solenoidal Large Intensity Device (SoLID) at Jefferson Lab, we are developing a simulation of a GEM chamber similar to the detectors currently used in our lab. We are also refining an object-oriented digitization program, which translates energy deposition information from GEMC into electronic readout which resembles the readout from our physical detectors. We have run the simulation with beta particles produced by the simulated decay of a 90Sr source, as well as with a simulated bremsstrahlung spectrum. Comparing the simulation data with real GEM data taken under similar conditions is used to refine the simulation parameters. Comparisons between results from the simulations and results from detector tests will be presented.

  4. The impact of the condenser on cytogenetic image quality in digital microscope system.

    PubMed

    Ren, Liqiang; Li, Zheng; Li, Yuhua; Zheng, Bin; Li, Shibo; Chen, Xiaodong; Liu, Hong

    2013-01-01

    Optimizing operational parameters of the digital microscope system is an important technique to acquire high quality cytogenetic images and facilitate the process of karyotyping so that the efficiency and accuracy of diagnosis can be improved. This study investigated the impact of the condenser on cytogenetic image quality and system working performance using a prototype digital microscope image scanning system. Both theoretical analysis and experimental validations through objectively evaluating a resolution test chart and subjectively observing large numbers of specimen were conducted. The results show that the optimal image quality and large depth of field (DOF) are simultaneously obtained when the numerical aperture of condenser is set as 60%-70% of the corresponding objective. Under this condition, more analyzable chromosomes and diagnostic information are obtained. As a result, the system shows higher working stability and less restriction for the implementation of algorithms such as autofocusing especially when the system is designed to achieve high throughput continuous image scanning. Although the above quantitative results were obtained using a specific prototype system under the experimental conditions reported in this paper, the presented evaluation methodologies can provide valuable guidelines for optimizing operational parameters in cytogenetic imaging using the high throughput continuous scanning microscopes in clinical practice.

  5. High aperture off-axis parabolic mirror applied in digital holographic microscopy

    NASA Astrophysics Data System (ADS)

    Kalenkov, Georgy S.; Kalenkov, Sergey G.; Shtanko, Alexander E.

    2018-04-01

    An optical scheme of recording digital holograms of micro-objects based on high numerical aperture off-axis parabolic mirror forming a high aperture reference wave is suggested. Registration of digital holograms based on the proposed optical scheme is confirmed experimentally. Application of the proposed approach for hyperspectral holograms registration of micro-objects in incoherent light is discussed.

  6. Smart Objects, Dumb Archives: A User-Centric, Layered Digital Library Framework

    NASA Technical Reports Server (NTRS)

    Maly, Kurt; Nelson, Michael L.; Zubair, Mohammad

    1999-01-01

    Currently, there exist a large number of superb digital libraries, all of which are, unfortunately, vertically integrated and all presenting a monolithic interface to their users. Ideally, a user would want to locate resources from a variety of digital libraries dealing only with one interface. A number of approaches exist to this interoperability issue exist including: defining a universal protocol for all libraries to adhere to; or developing mechanisms to translate between protocols. The approach we illustrate in this paper is to push down the level of universal protocols to one for digital object communication and for communication for simple archives. This approach creates the opportunity for digital library service providers to create digital libraries tailored to the needs of user communities drawing from available archives and individual publishers who adhere to this standard. We have created a reference implementation based on the hyper text transfer protocol (http) with the protocols being derived from the Dienst protocol. We have created a special class of digital objects called buckets and a number of archives based on a NASA collection and NSF funded projects. Starting from NCSTRL we have developed a set of digital library services called NCSTRL+ and have created digital libraries for researchers, educators and students that can each draw on all the archives and individually created buckets.

  7. Three-dimensional information extraction from GaoFen-1 satellite images for landslide monitoring

    NASA Astrophysics Data System (ADS)

    Wang, Shixin; Yang, Baolin; Zhou, Yi; Wang, Futao; Zhang, Rui; Zhao, Qing

    2018-05-01

    To more efficiently use GaoFen-1 (GF-1) satellite images for landslide emergency monitoring, a Digital Surface Model (DSM) can be generated from GF-1 across-track stereo image pairs to build a terrain dataset. This study proposes a landslide 3D information extraction method based on the terrain changes of slope objects. The slope objects are mergences of segmented image objects which have similar aspects; and the terrain changes are calculated from the post-disaster Digital Elevation Model (DEM) from GF-1 and the pre-disaster DEM from GDEM V2. A high mountain landslide that occurred in Wenchuan County, Sichuan Province is used to conduct a 3D information extraction test. The extracted total area of the landslide is 22.58 ha; the displaced earth volume is 652,100 m3; and the average sliding direction is 263.83°. The accuracies of them are 0.89, 0.87 and 0.95, respectively. Thus, the proposed method expands the application of GF-1 satellite images to the field of landslide emergency monitoring.

  8. Digital imaging and image analysis applied to numerical applications in forensic hair examination.

    PubMed

    Brooks, Elizabeth; Comber, Bruce; McNaught, Ian; Robertson, James

    2011-03-01

    A method that provides objective data to complement the hair analysts' microscopic observations, which is non-destructive, would be of obvious benefit in the forensic examination of hairs. This paper reports on the use of objective colour measurement and image analysis techniques of auto-montaged images. Brown Caucasian telogen scalp hairs were chosen as a stern test of the utility of these approaches. The results show the value of using auto-montaged images and the potential for the use of objective numerical measures of colour and pigmentation to complement microscopic observations. 2010. Published by Elsevier Ireland Ltd. All rights reserved.

  9. Preservation of Digital Objects.

    ERIC Educational Resources Information Center

    Galloway, Patricia

    2004-01-01

    Presents a literature review that covers the following topics related to preservation of digital objects: practical examples; stakeholders; recordkeeping standards; genre-specific problems; trusted repository standards; preservation methods; preservation metadata standards; and future directions. (Contains 82 references.) (MES)

  10. Combined holography and thermography in a single sensor through image-plane holography at thermal infrared wavelengths.

    PubMed

    Georges, Marc P; Vandenrijt, Jean-François; Thizy, Cédric; Alexeenko, Igor; Pedrini, Giancarlo; Vollheim, Birgit; Lopez, Ion; Jorge, Iagoba; Rochet, Jonathan; Osten, Wolfgang

    2014-10-20

    Holographic interferometry in the thermal wavelengths range, combining a CO(2) laser and digital hologram recording with a microbolometer array based camera, allows simultaneously capturing temperature and surface shape information about objects. This is due to the fact that the holograms are affected by the thermal background emitted by objects at room temperature. We explain the setup and the processing of data which allows decoupling the two types of information. This natural data fusion can be advantageously used in a variety of nondestructive testing applications.

  11. Development and testing of 2-dimensional photon counter

    NASA Technical Reports Server (NTRS)

    1981-01-01

    The development of a commercially available two dimensional photon counter into an operational system for speckle imaging of astronomical objects is described. The system includes digital recording for field observations. The counter has a bialkali photocathode with a field size of 18 by 18 mm over which it resolves about 100 by 100 pixels. The system records photon positions as 16 bit words at rates up to 14,400 per second. Field tests at observatories verifying the operation of the system are described.

  12. Aspect Determination Using a Beacon with a Spiral Wave Front: Modeling and Performance Analysis in Operational Environments

    DTIC Science & Technology

    2014-12-19

    used to evaluate the beacon performance at the Navy’s Seneca Lake Sonar Test Facility operated by NUWC-Newport. These tests occurred in the summer...prototype has been designed. Efforts have been underway to implement the spiral beacon into the Navy’s Sonar Simulation Toolset developed by Dr. Robert...mil). Digital Object Identifier 10.1109/JOE.2013.2293962 acoustic depth finding or sonar imaging may be compared with maps to coordinate position and

  13. Remembering Math: The Design of Digital Learning Objects to Spark Professional Learning

    ERIC Educational Resources Information Center

    Halverson, Richard; Wolfenstein, Moses; Williams, Caroline C.; Rockman, Charles

    2009-01-01

    This article describes how the design of digital learning objects can spark professional learning. The challenge was to build learning objects that would help experienced special education teachers, who had been teaching in math classes, to demonstrate their proficiency in middle and secondary school mathematics on the PRAXIS examination. While…

  14. Incoherent digital holograms acquired by interferenceless coded aperture correlation holography system without refractive lenses.

    PubMed

    Kumar, Manoj; Vijayakumar, A; Rosen, Joseph

    2017-09-14

    We present a lensless, interferenceless incoherent digital holography technique based on the principle of coded aperture correlation holography. The acquired digital hologram by this technique contains a three-dimensional image of some observed scene. Light diffracted by a point object (pinhole) is modulated using a random-like coded phase mask (CPM) and the intensity pattern is recorded and composed as a point spread hologram (PSH). A library of PSHs is created using the same CPM by moving the pinhole to all possible axial locations. Intensity diffracted through the same CPM from an object placed within the axial limits of the PSH library is recorded by a digital camera. The recorded intensity this time is composed as the object hologram. The image of the object at any axial plane is reconstructed by cross-correlating the object hologram with the corresponding component of the PSH library. The reconstruction noise attached to the image is suppressed by various methods. The reconstruction results of multiplane and thick objects by this technique are compared with regular lens-based imaging.

  15. Creating a Framework of Guidance for Building Good Digital Collections.

    ERIC Educational Resources Information Center

    Cole, Timothy W.

    2002-01-01

    Presents the Framework of Guidance for Building Good Digital Collections that was developed by the Institute of Museum and Library Services with other organizations to guide museums and libraries in digitization collection practices. Highlights digital collections, digital objects, and metadata, and discusses reusability, persistence,…

  16. Test and control computer user's guide for a digital beam former test system

    NASA Technical Reports Server (NTRS)

    Alexovich, Robert E.; Mallasch, Paul G.

    1992-01-01

    A Digital Beam Former Test System was developed to determine the effects of noise, interferers and distortions, and digital implementations of beam forming as applied to the Tracking and Data Relay Satellite 2 (TDRS 2) architectures. The investigation of digital beam forming with application to TDRS 2 architectures, as described in TDRS 2 advanced concept design studies, was conducted by the NASA/Lewis Research Center for NASA/Goddard Space Flight Center. A Test and Control Computer (TCC) was used as the main controlling element of the digital Beam Former Test System. The Test and Control Computer User's Guide for a Digital Beam Former Test System provides an organized description of the Digital Beam Former Test System commands. It is written for users who wish to conduct tests of the Digital Beam forming Test processor using the TCC. The document describes the function, use, and syntax of the TCC commands available to the user while summarizing and demonstrating the use of the commands wtihin DOS batch files.

  17. ESDORA: A Data Archive Infrastructure Using Digital Object Model and Open Source Frameworks

    NASA Astrophysics Data System (ADS)

    Shrestha, Biva; Pan, Jerry; Green, Jim; Palanisamy, Giriprakash; Wei, Yaxing; Lenhardt, W.; Cook, R. Bob; Wilson, B. E.; Leggott, M.

    2011-12-01

    There are an array of challenges associated with preserving, managing, and using contemporary scientific data. Large volume, multiple formats and data services, and the lack of a coherent mechanism for metadata/data management are some of the common issues across data centers. It is often difficult to preserve the data history and lineage information, along with other descriptive metadata, hindering the true science value for the archived data products. In this project, we use digital object abstraction architecture as the information/knowledge framework to address these challenges. We have used the following open-source frameworks: Fedora-Commons Repository, Drupal Content Management System, Islandora (Drupal Module) and Apache Solr Search Engine. The system is an active archive infrastructure for Earth Science data resources, which include ingestion, archiving, distribution, and discovery functionalities. We use an ingestion workflow to ingest the data and metadata, where many different aspects of data descriptions (including structured and non-structured metadata) are reviewed. The data and metadata are published after reviewing multiple times. They are staged during the reviewing phase. Each digital object is encoded in XML for long-term preservation of the content and relations among the digital items. The software architecture provides a flexible, modularized framework for adding pluggable user-oriented functionality. Solr is used to enable word search as well as faceted search. A home grown spatial search module is plugged in to allow user to make a spatial selection in a map view. A RDF semantic store within the Fedora-Commons Repository is used for storing information on data lineage, dissemination services, and text-based metadata. We use the semantic notion "isViewerFor" to register internally or externally referenced URLs, which are rendered within the same web browser when possible. With appropriate mapping of content into digital objects, many different data descriptions, including structured metadata, data history, auditing trails, are captured and coupled with the data content. The semantic store provides a foundation for possible further utilizations, including provide full-fledged Earth Science ontology for data interpretation or lineage tracking. Datasets from the NASA-sponsored Oak Ridge National Laboratory Distributed Active Archive Center (ORNL DAAC) as well as from the Synthesis Thematic Data Center (MAST-DC) are used in a testing deployment with the system. The testing deployment allows us to validate the features and values described here for the integrated system, which will be presented here. Overall, we believe that the integrated system is valid, reusable data archive software that provides digital stewardship for Earth Sciences data content, now and in the future. References: [1] Devarakonda, Ranjeet, and Harold Shanafield. "Drupal: Collaborative framework for science research." Collaboration Technologies and Systems (CTS), 2011 International Conference on. IEEE, 2011. [2] Devarakonda, Ranjeet, et al. "Semantic search integration to climate data." Collaboration Technologies and Systems (CTS), 2014 International Conference on. IEEE, 2014.

  18. The 3D Digital Story-telling Media on Batik Learning in Vocational High Schools

    NASA Astrophysics Data System (ADS)

    Widiaty, I.; Achdiani, Y.; Kuntadi, I.; Mubaroq, S. R.; Zakaria, D.

    2018-02-01

    The aim of this research is to make 3D digital Story-telling Media on Batik Learning in Vocational High School. The digital story-telling developed in this research is focused on 3D-based story-telling. In contrast to the digital story-telling that has been developed in existing learning, this research is expected to be able to improve understanding of vocational students about the value of local wisdom batik more meaningful and “live”. The process of making 3D digital story-telling media consists of two processes, namely the creation of 3D objects and the creation of 3D object viewer.

  19. Novel algorithm to identify and differentiate specific digital signature of breath sound in patients with diffuse parenchymal lung disease.

    PubMed

    Bhattacharyya, Parthasarathi; Mondal, Ashok; Dey, Rana; Saha, Dipanjan; Saha, Goutam

    2015-05-01

    Auscultation is an important part of the clinical examination of different lung diseases. Objective analysis of lung sounds based on underlying characteristics and its subsequent automatic interpretations may help a clinical practice. We collected the breath sounds from 8 normal subjects and 20 diffuse parenchymal lung disease (DPLD) patients using a newly developed instrument and then filtered off the heart sounds using a novel technology. The collected sounds were thereafter analysed digitally on several characteristics as dynamical complexity, texture information and regularity index to find and define their unique digital signatures for differentiating normality and abnormality. For convenience of testing, these characteristic signatures of normal and DPLD lung sounds were transformed into coloured visual representations. The predictive power of these images has been validated by six independent observers that include three physicians. The proposed method gives a classification accuracy of 100% for composite features for both the normal as well as lung sound signals from DPLD patients. When tested by independent observers on the visually transformed images, the positive predictive value to diagnose the normality and DPLD remained 100%. The lung sounds from the normal and DPLD subjects could be differentiated and expressed according to their digital signatures. On visual transformation to coloured images, they retain 100% predictive power. This technique may assist physicians to diagnose DPLD from visual images bearing the digital signature of the condition. © 2015 Asian Pacific Society of Respirology.

  20. Northeast Artificial Intelligence Consortium (NAIC) Review of Technical Tasks. Volume 2, Part 1.

    DTIC Science & Technology

    1987-07-01

    34- . 6.2 Transformation Invariant Attributes for S Digitized Object Outlines ................................. 469 6.3 Design of an Inference Engine for an...Attributes for Digital Object Outlines ...................................... 597 7 SPEECH UNDERSTANDING RESEARCH ( Rochester Institute of Technology...versatile maintenance expert system ES) for trouble-shooting--’ digital circuits. +" Some diagnosis systems, such as MYCLN [19] for medical diagnosis and CRIB

  1. In-Factory Learning - Qualification For The Factory Of The Future

    NASA Astrophysics Data System (ADS)

    Quint, Fabian; Mura, Katharina; Gorecky, Dominic

    2015-07-01

    The Industry 4.0 vision anticipates that internet technologies will find their way into future factories replacing traditional components by dynamic and intelligent cyber-physical systems (CPS) that combine the physical objects with their digital representation. Reducing the gap between the real and digital world makes the factory environment more flexible, more adaptive, but also more complex for the human workers. Future workers require interdisciplinary competencies from engineering, information technology, and computer science in order to understand and manage the diverse interrelations between physical objects and their digital counterpart. This paper proposes a mixed-reality based learning environment, which combines physical objects and visualisation of digital content via Augmented Reality. It uses reality-based interaction in order to make the dynamic interrelations between real and digital factory visible and tangible. We argue that our learning system does not work as a stand-alone solution, but should fit into existing academic and advanced training curricula.

  2. Relation between speech-in-noise threshold, hearing loss and cognition from 40-69 years of age.

    PubMed

    Moore, David R; Edmondson-Jones, Mark; Dawes, Piers; Fortnum, Heather; McCormack, Abby; Pierzycki, Robert H; Munro, Kevin J

    2014-01-01

    Healthy hearing depends on sensitive ears and adequate brain processing. Essential aspects of both hearing and cognition decline with advancing age, but it is largely unknown how one influences the other. The current standard measure of hearing, the pure-tone audiogram is not very cognitively demanding and does not predict well the most important yet challenging use of hearing, listening to speech in noisy environments. We analysed data from UK Biobank that asked 40-69 year olds about their hearing, and assessed their ability on tests of speech-in-noise hearing and cognition. About half a million volunteers were recruited through NHS registers. Respondents completed 'whole-body' testing in purpose-designed, community-based test centres across the UK. Objective hearing (spoken digit recognition in noise) and cognitive (reasoning, memory, processing speed) data were analysed using logistic and multiple regression methods. Speech hearing in noise declined exponentially with age for both sexes from about 50 years, differing from previous audiogram data that showed a more linear decline from <40 years for men, and consistently less hearing loss for women. The decline in speech-in-noise hearing was especially dramatic among those with lower cognitive scores. Decreasing cognitive ability and increasing age were both independently associated with decreasing ability to hear speech-in-noise (0.70 and 0.89 dB, respectively) among the population studied. Men subjectively reported up to 60% higher rates of difficulty hearing than women. Workplace noise history associated with difficulty in both subjective hearing and objective speech hearing in noise. Leisure noise history was associated with subjective, but not with objective difficulty hearing. Older people have declining cognitive processing ability associated with reduced ability to hear speech in noise, measured by recognition of recorded spoken digits. Subjective reports of hearing difficulty generally show a higher prevalence than objective measures, suggesting that current objective methods could be extended further.

  3. Relation between Speech-in-Noise Threshold, Hearing Loss and Cognition from 40–69 Years of Age

    PubMed Central

    Moore, David R.; Edmondson-Jones, Mark; Dawes, Piers; Fortnum, Heather; McCormack, Abby; Pierzycki, Robert H.; Munro, Kevin J.

    2014-01-01

    Background Healthy hearing depends on sensitive ears and adequate brain processing. Essential aspects of both hearing and cognition decline with advancing age, but it is largely unknown how one influences the other. The current standard measure of hearing, the pure-tone audiogram is not very cognitively demanding and does not predict well the most important yet challenging use of hearing, listening to speech in noisy environments. We analysed data from UK Biobank that asked 40–69 year olds about their hearing, and assessed their ability on tests of speech-in-noise hearing and cognition. Methods and Findings About half a million volunteers were recruited through NHS registers. Respondents completed ‘whole-body’ testing in purpose-designed, community-based test centres across the UK. Objective hearing (spoken digit recognition in noise) and cognitive (reasoning, memory, processing speed) data were analysed using logistic and multiple regression methods. Speech hearing in noise declined exponentially with age for both sexes from about 50 years, differing from previous audiogram data that showed a more linear decline from <40 years for men, and consistently less hearing loss for women. The decline in speech-in-noise hearing was especially dramatic among those with lower cognitive scores. Decreasing cognitive ability and increasing age were both independently associated with decreasing ability to hear speech-in-noise (0.70 and 0.89 dB, respectively) among the population studied. Men subjectively reported up to 60% higher rates of difficulty hearing than women. Workplace noise history associated with difficulty in both subjective hearing and objective speech hearing in noise. Leisure noise history was associated with subjective, but not with objective difficulty hearing. Conclusions Older people have declining cognitive processing ability associated with reduced ability to hear speech in noise, measured by recognition of recorded spoken digits. Subjective reports of hearing difficulty generally show a higher prevalence than objective measures, suggesting that current objective methods could be extended further. PMID:25229622

  4. Evaluating a smartphone digits-in-noise test as part of the audiometric test battery.

    PubMed

    Potgieter, Jenni-Mari; Swanepoel, De Wet; Smits, Cas

    2018-05-21

     Speech-in-noise tests have become a valuable part of the audiometric test battery providing an indication of a listener's ability to function in background noise. A simple digits-in-noise (DIN) test could be valuable to support diagnostic hearing assessments, hearing aid fittings and counselling for both paediatric and adult populations. Objective: The objective of this study was to evaluate the South African English smartphone DIN test's performance as part of the audiometric test battery. Design: This descriptive study evaluated 109 adult subjects (43 male and 66 female subjects) with and without sensorineural hearing loss by comparing pure-tone air conduction thresholds, speech recognition monaural performance scores (SRS dB) and the DIN speech reception threshold (SRT). An additional nine adult hearing aid users (four male and five female subjects) were included in a subset to determine aided and unaided DIN SRTs. Results: The DIN SRT is strongly associated with the best ear 4 frequency pure-tone average (4FPTA) (rs = 0.81) and maximum SRS dB (r = 0.72). The DIN test had high sensitivity and specificity to identify abnormal pure-tone (0.88 and 0.88, respectively) and SRS dB (0.76 and 0.88, respectively) results. There was a mean signal-to-noise ratio (SNR) improvement in the aided condition that demonstrated an overall benefit of 0.84 SNR dB. Conclusion: The DIN SRT was significantly correlated with the best ear 4FPTA and maximum SRS dB. The DIN SRT provides a useful measure of speech recognition in noise that can evaluate hearing aid fittings, manage counselling and hearing expectations.

  5. Collection Metadata Solutions for Digital Library Applications

    NASA Technical Reports Server (NTRS)

    Hill, Linda L.; Janee, Greg; Dolin, Ron; Frew, James; Larsgaard, Mary

    1999-01-01

    Within a digital library, collections may range from an ad hoc set of objects that serve a temporary purpose to established library collections intended to persist through time. The objects in these collections vary widely, from library and data center holdings to pointers to real-world objects, such as geographic places, and the various metadata schemas that describe them. The key to integrated use of such a variety of collections in a digital library is collection metadata that represents the inherent and contextual characteristics of a collection. The Alexandria Digital Library (ADL) Project has designed and implemented collection metadata for several purposes: in XML form, the collection metadata "registers" the collection with the user interface client; in HTML form, it is used for user documentation; eventually, it will be used to describe the collection to network search agents; and it is used for internal collection management, including mapping the object metadata attributes to the common search parameters of the system.

  6. Spatial-heterodyne interferometry for transmission (SHIFT) measurements

    DOEpatents

    Bingham, Philip R.; Hanson, Gregory R.; Tobin, Ken W.

    2006-10-10

    Systems and methods are described for spatial-heterodyne interferometry for transmission (SHIFT) measurements. A method includes digitally recording a spatially-heterodyned hologram including spatial heterodyne fringes for Fourier analysis using a reference beam, and an object beam that is transmitted through an object that is at least partially translucent; Fourier analyzing the digitally recorded spatially-heterodyned hologram, by shifting an original origin of the digitally recorded spatially-heterodyned hologram to sit on top of a spatial-heterodyne carrier frequency defined by an angle between the reference beam and the object beam, to define an analyzed image; digitally filtering the analyzed image to cut off signals around the original origin to define a result; and performing an inverse Fourier transform on the result.

  7. Catalytic Combustion for Ultra-Low NOx Hydrogen Turbines

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Etemad, Shahrokh; Baird, Benjamin; Alavandi, Sandeep

    2011-06-30

    Precision Combustion, Inc., (PCI) in close collaboration with Solar Turbines, Incorporated, has developed and demonstrated a combustion system for hydrogen fueled turbines that reduces NOx to low single digit level while maintaining or improving current levels of efficiency and eliminating emissions of carbon dioxide. Full scale Rich Catalytic Hydrogen (RCH1) injector was developed and successfully tested at Solar Turbines, Incorporated high pressure test facility demonstrating low single digit NOx emissions for hydrogen fuel in the range of 2200F-2750F. This development work was based on initial subscale development for faster turnaround and reduced cost. Subscale testing provided promising results for 42%more » and 52% H2 with NOx emissions of less than 2 ppm with improved flame stability. In addition, catalytic reactor element testing for substrate oxidation, thermal cyclic injector testing to simulate start-stop operation in a gas turbine environment, and steady state 15 atm. operation testing were performed successfully. The testing demonstrated stable and robust catalytic element component life for gas turbine conditions. The benefit of the catalytic hydrogen combustor technology includes capability of delivering near-zero NOx without costly post-combustion controls and without requirement for added sulfur control. In addition, reduced acoustics increase gas turbine component life. These advantages advances Department of Energy (DOE’s) objectives for achievement of low single digit NOx emissions, improvement in efficiency vs. postcombustion controls, fuel flexibility, a significant net reduction in Integrated Gasification Combined Cycle (IGCC) system net capital and operating costs, and a route to commercialization across the power generation field from micro turbines to industrial and utility turbines.« less

  8. Off-axis illumination direct-to-digital holography

    DOEpatents

    Thomas, Clarence E.; Price, Jeffery R.; Voelkl, Edgar; Hanson, Gregory R.

    2004-06-08

    Systems and methods are described for off-axis illumination direct-to-digital holography. A method of recording an off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis, includes: reflecting a reference beam from a reference mirror at a non-normal angle; reflecting an object beam from an object at an angle with respect to an optical axis defined by a focusing lens; focusing the reference beam and the object beam at a focal plane of a digital recorder to form the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; digitally recording the off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes for Fourier analysis; Fourier analyzing the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes by transforming axes of the recorded off-axis illuminated spatially heterodyne hologram including spatially heterodyne fringes in Fourier space to sit on top of a heterodyne carrier frequency defined as an angle between the reference beam and the object beam; applying a digital filter to cut off signals around an original origin; and then performing an inverse Fourier transform.

  9. A Next Generation Digital Counting System For Low-Level Tritium Studies (Project Report)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowman, P.

    2016-10-03

    Since the early seventies, SRNL has pioneered low-level tritium analysis using various nuclear counting technologies and techniques. Since 1999, SRNL has successfully performed routine low-level tritium analyses with counting systems based on digital signal processor (DSP) modules developed in the late 1990s. Each of these counting systems are complex, unique to SRNL, and fully dedicated to performing routine tritium analyses of low-level environmental samples. It is time to modernize these systems due to a variety of issues including (1) age, (2) lack of direct replacement electronics modules and (3) advances in digital signal processing and computer technology. There has beenmore » considerable development in many areas associated with the enterprise of performing low-level tritium analyses. The objective of this LDRD project was to design, build, and demonstrate a Next Generation Tritium Counting System (NGTCS), while not disrupting the routine low-level tritium analyses underway in the facility on the legacy counting systems. The work involved (1) developing a test bed for building and testing new counting system hardware that does not interfere with our routine analyses, (2) testing a new counting system based on a modern state of the art DSP module, and (3) evolving the low-level tritium counter design to reflect the state of the science.« less

  10. Does Digital Video Advertising Increase Population-Level Reach of Multimedia Campaigns? Evidence From the 2013 Tips From Former Smokers Campaign

    PubMed Central

    Shafer, Paul R; Rodes, Robert; Kim, Annice; Hansen, Heather; Patel, Deesha; Coln, Caryn; Beistle, Diane

    2016-01-01

    Background Federal and state public health agencies in the United States are increasingly using digital advertising and social media to promote messages from broader multimedia campaigns. However, little evidence exists on population-level campaign awareness and relative cost efficiencies of digital advertising in the context of a comprehensive public health education campaign. Objective Our objective was to compare the impact of increased doses of digital video and television advertising from the 2013 Tips From Former Smokers (Tips) campaign on overall campaign awareness at the population level. We also compared the relative cost efficiencies across these media platforms. Methods We used data from a large national online survey of approximately 15,000 US smokers conducted in 2013 immediately after the conclusion of the 2013 Tips campaign. These data were used to compare the effects of variation in media dose of digital video and television advertising on population-level awareness of the Tips campaign. We implemented higher doses of digital video among selected media markets and randomly selected other markets to receive similar higher doses of television ads. Multivariate logistic regressions estimated the odds of overall campaign awareness via digital or television format as a function of higher-dose media in each market area. All statistical tests used the .05 threshold for statistical significance and the .10 level for marginal nonsignificance. We used adjusted advertising costs for the additional doses of digital and television advertising to compare the cost efficiencies of digital and television advertising on the basis of costs per percentage point of population awareness generated. Results Higher-dose digital video advertising was associated with 94% increased odds of awareness of any ad online relative to standard-dose markets (P<.001). Higher-dose digital advertising was associated with a marginally nonsignificant increase (46%) in overall campaign awareness regardless of media format (P=.09). Higher-dose television advertising was associated with 81% increased odds of overall ad awareness regardless of media format (P<.001). Increased doses of television advertising were also associated with significantly higher odds of awareness of any ad on television (P<.001) and online (P=.04). The adjusted cost of each additional percentage point of population-level reach generated by higher doses of advertising was approximately US $440,000 for digital advertising and US $1 million for television advertising. Conclusions Television advertising generated relatively higher levels of overall campaign awareness. However, digital video was relatively more cost efficient for generating awareness. These results suggest that digital video may be used as a cost-efficient complement to traditional advertising modes (eg, television), but digital video should not replace television given the relatively smaller audience size of digital video viewers. PMID:27627853

  11. Accuracy and Landmark Error Calculation Using Cone-Beam Computed Tomography–Generated Cephalograms

    PubMed Central

    Grauer, Dan; Cevidanes, Lucia S. H.; Styner, Martin A.; Heulfe, Inam; Harmon, Eric T.; Zhu, Hongtu; Proffit, William R.

    2010-01-01

    Objective To evaluate systematic differences in landmark position between cone-beam computed tomography (CBCT)–generated cephalograms and conventional digital cephalograms and to estimate how much variability should be taken into account when both modalities are used within the same longitudinal study. Materials and Methods Landmarks on homologous cone-beam computed tomographic–generated cephalograms and conventional digital cephalograms of 46 patients were digitized, registered, and compared via the Hotelling T2 test. Results There were no systematic differences between modalities in the position of most landmarks. Three landmarks showed statistically significant differences but did not reach clinical significance. A method for error calculation while combining both modalities in the same individual is presented. Conclusion In a longitudinal follow-up for assessment of treatment outcomes and growth of one individual, the error due to the combination of the two modalities might be larger than previously estimated. PMID:19905853

  12. Continuous-wave terahertz digital holography by use of a pyroelectric array camera.

    PubMed

    Ding, Sheng-Hui; Li, Qi; Li, Yun-Da; Wang, Qi

    2011-06-01

    Terahertz (THz) digital holography is realized based on a 2.52 THz far-IR gas laser and a commercial 124 × 124 pyroelectric array camera. Off-axis THz holograms are obtained by recording interference patterns between light passing through the sample and the reference wave. A numerical reconstruction process is performed to obtain the field distribution at the object surface. Different targets were imaged to test the system's imaging capability. Compared with THz focal plane images, the image quality of the reconstructed images are improved a lot. The results show that the system's imaging resolution can reach at least 0.4 mm. The system also has the potential for real-time imaging application. This study confirms that digital holography is a promising technique for real-time, high-resolution THz imaging, which has extensive application prospects. © 2011 Optical Society of America

  13. Photogrammetry of a 5m Inflatable Space Antenna With Consumer Digital Cameras

    NASA Technical Reports Server (NTRS)

    Pappa, Richard S.; Giersch, Louis R.; Quagliaroli, Jessica M.

    2000-01-01

    This paper discusses photogrammetric measurements of a 5m-diameter inflatable space antenna using four Kodak DC290 (2.1 megapixel) digital cameras. The study had two objectives: 1) Determine the photogrammetric measurement precision obtained using multiple consumer-grade digital cameras and 2) Gain experience with new commercial photogrammetry software packages, specifically PhotoModeler Pro from Eos Systems, Inc. The paper covers the eight steps required using this hardware/software combination. The baseline data set contained four images of the structure taken from various viewing directions. Each image came from a separate camera. This approach simulated the situation of using multiple time-synchronized cameras, which will be required in future tests of vibrating or deploying ultra-lightweight space structures. With four images, the average measurement precision for more than 500 points on the antenna surface was less than 0.020 inches in-plane and approximately 0.050 inches out-of-plane.

  14. Spatial carrier color digital speckle pattern interferometry for absolute three-dimensional deformation measurement

    NASA Astrophysics Data System (ADS)

    Gao, Xinya; Wang, Yonghong; Li, Junrui; Dan, Xizuo; Wu, Sijin; Yang, Lianxiang

    2017-06-01

    It is difficult to measure absolute three-dimensional deformation using traditional digital speckle pattern interferometry (DSPI) when the boundary condition of an object being tested is not exactly given. In practical applications, the boundary condition cannot always be specifically provided, limiting the use of DSPI in real-world applications. To tackle this problem, a DSPI system that is integrated by the spatial carrier method and a color camera has been established. Four phase maps are obtained simultaneously by spatial carrier color-digital speckle pattern interferometry using four speckle interferometers with different illumination directions. One out-of-plane and two in-plane absolute deformations can be acquired simultaneously without knowing the boundary conditions using the absolute deformation extraction algorithm based on four phase maps. Finally, the system is proved by experimental results through measurement of the deformation of a flat aluminum plate with a groove.

  15. Development of Mission Adaptive Digital Composite Aerostructure Technologies (MADCAT)

    NASA Technical Reports Server (NTRS)

    Cheung, Kenneth; Cellucci, Daniel; Copplestone, Grace; Cramer, Nick; Fusco, Jesse; Jenett, Benjamin; Kim, Joseph; Mazhari, Alex; Trinh, Greenfield; Swei, Sean

    2017-01-01

    This paper reviews the development of the Mission Adaptive Digital Composite Aerostructures Technologies (MADCAT) v0 demonstrator aircraft, utilizing a novel aerostructure concept that combines advanced composite materials manufacturing and fabrication technologies with a discrete construction approach to achieve high stiffness-to-density ratio ultra-light aerostructures that provide versatility and adaptability. This revolutionary aerostructure concept has the potential to change how future air vehicles are designed, built, and flown, with dramatic reductions in weight and manufacturing complexity the number of types of structural components needed to build air vehicles while enabling new mission objectives. We utilize the innovative digital composite materials and discrete construction technologies to demonstrate the feasibility of the proposed aerostructure concept, by building and testing a scaled prototype UAV, MADCAT v0. This paper presents an overview of the design and development of the MADCAT v0 flight demonstrator.

  16. Superresolved digital in-line holographic microscopy for high-resolution lensless biological imaging

    NASA Astrophysics Data System (ADS)

    Micó, Vicente; Zalevsky, Zeev

    2010-07-01

    Digital in-line holographic microscopy (DIHM) is a modern approach capable of achieving micron-range lateral and depth resolutions in three-dimensional imaging. DIHM in combination with numerical imaging reconstruction uses an extremely simplified setup while retaining the advantages provided by holography with enhanced capabilities derived from algorithmic digital processing. We introduce superresolved DIHM incoming from time and angular multiplexing of the sample spatial frequency information and yielding in the generation of a synthetic aperture (SA). The SA expands the cutoff frequency of the imaging system, allowing submicron resolutions in both transversal and axial directions. The proposed approach can be applied when imaging essentially transparent (low-concentration dilutions) and static (slow dynamics) samples. Validation of the method for both a synthetic object (U.S. Air Force resolution test) to quantify the resolution improvement and a biological specimen (sperm cells biosample) are reported showing the generation of high synthetic numerical aperture values working without lenses.

  17. Evaluation of the geometric stability and the accuracy potential of digital cameras — Comparing mechanical stabilisation versus parameterisation

    NASA Astrophysics Data System (ADS)

    Rieke-Zapp, D.; Tecklenburg, W.; Peipe, J.; Hastedt, H.; Haig, Claudia

    Recent tests on the geometric stability of several digital cameras that were not designed for photogrammetric applications have shown that the accomplished accuracies in object space are either limited or that the accuracy potential is not exploited to the fullest extent. A total of 72 calibrations were calculated with four different software products for eleven digital camera models with different hardware setups, some with mechanical fixation of one or more parts. The calibration procedure was chosen in accord to a German guideline for evaluation of optical 3D measuring systems [VDI/VDE, VDI/VDE 2634 Part 1, 2002. Optical 3D Measuring Systems-Imaging Systems with Point-by-point Probing. Beuth Verlag, Berlin]. All images were taken with ringflashes which was considered a standard method for close-range photogrammetry. In cases where the flash was mounted to the lens, the force exerted on the lens tube and the camera mount greatly reduced the accomplished accuracy. Mounting the ringflash to the camera instead resulted in a large improvement of accuracy in object space. For standard calibration best accuracies in object space were accomplished with a Canon EOS 5D and a 35 mm Canon lens where the focusing tube was fixed with epoxy (47 μm maximum absolute length measurement error in object space). The fixation of the Canon lens was fairly easy and inexpensive resulting in a sevenfold increase in accuracy compared with the same lens type without modification. A similar accuracy was accomplished with a Nikon D3 when mounting the ringflash to the camera instead of the lens (52 μm maximum absolute length measurement error in object space). Parameterisation of geometric instabilities by introduction of an image variant interior orientation in the calibration process improved results for most cameras. In this case, a modified Alpa 12 WA yielded the best results (29 μm maximum absolute length measurement error in object space). Extending the parameter model with FiBun software to model not only an image variant interior orientation, but also deformations in the sensor domain of the cameras, showed significant improvements only for a small group of cameras. The Nikon D3 camera yielded the best overall accuracy (25 μm maximum absolute length measurement error in object space) with this calibration procedure indicating at the same time the presence of image invariant error in the sensor domain. Overall, calibration results showed that digital cameras can be applied for an accurate photogrammetric survey and that only a little effort was sufficient to greatly improve the accuracy potential of digital cameras.

  18. How do young and senior cytopathologists interact with digital cytology?

    PubMed

    Giovagnoli, Maria Rosaria; Giarnieri, Enrico; Carico, Elisabetta; Giansanti, Daniele

    2010-01-01

    Today thanks to the technological advances in information technology the scenario of utilization of digital cytology has radically changed. New competitive systems, such as client-server architectures are now available in digital cytology. Their application in telemedicine should be investigated. A new interactive tool designed for the final destination user (the cytopathologist) has been proposed. Taking into account the different expertise of the subjects of the study, the investigation was focused both on the senior cytopathologist and on the younger student pathologist. The methodology was tested on 10 students of a Master in cytopathology and on 3 senior cytopathologists. The study showed that the use of digital cytology applications is effective and feasible for telediagnosis. In particular, the study on younger and senior expert investigators showed that, although they interacted with the novel technology of the virtual slide in a different manner, all of them reached the objective of a "correct diagnosis". This investigation, in consideration of the effectiveness of the digital cytology, also showed other indirect and tangible cost-beneft and quantitative advantages. In particular for the learning methodologies for the students of the Master itself and for the biomedical personnel involved in diagnosis.

  19. Effects on Cognition of Stereotactic Lesional Surgery For the Treatment of Tremor in Multiple Sclerosis

    PubMed Central

    Jahanshahi, Marjan; Pieter, Socorro; Alusi, Sundus H.; Jones, Catherine R. G.; Glickman, Scott; Stein, John; Aziz, Tipu; Bain, Peter G.

    2008-01-01

    Objective: To assess the effect of stereotactic lesional surgery for treatment of tremor in multiple sclerosis on cognition. Methods: Eleven patients (3 males, 8 females) with multiple sclerosis participated in the study. Six subjects comprised the surgical group and five the matched control group. All patients were assessed at baseline and three months using a neuropsychological test battery that included measures of intellectual ability, memory, language, perception and executive function. Results: There were no significant differences between the surgical and control groups and no change from pre to post testing except for a decline in scores on the Mini-Mental State Examination (MMSE), WAIS-R Digit Span and Verbal Fluency in the surgical group. Conclusions: The results indicate that stereotactic lesional surgery does not result in major cognitive impairment in multiple sclerosis. However, the decline in MMSE scores, digit span and verbal fluency require further investigation in a larger sample. PMID:19491469

  20. The Research Library's Role in Digital Repository Services: Final Report of the ARL Digital Repository Issues Task Force

    ERIC Educational Resources Information Center

    Association of Research Libraries, 2009

    2009-01-01

    Libraries are making diverse contributions to the development of many types of digital repositories, particularly those housing locally created digital content, including new digital objects or digitized versions of locally held works. In some instances, libraries are managing a repository and its related services entirely on their own, but often…

  1. Shade selection performed by novice dental professionals and colorimeter.

    PubMed

    Klemetti, E; Matela, A-M; Haag, P; Kononen, M

    2006-01-01

    The objective of this study was to test inter-observer variability in shade selection for porcelain restorations, using three different shade guides: Vita Lumin Vacuum, Vita 3D-Master and Procera. Nineteen young dental professionals acted as observers. The results were also compared with those of a digital colorimeter (Shade Eye Ex; Shofu, Japan). Regarding repeatability, no significant differences were found between the three shade guides, although repeatability was relatively low (33-43%). Agreement with the colorimetric results was also low (8-34%). In conclusion, shade selection shows moderate to great inter-observer variation. In teaching and standardizing the shade selection procedure, a digital colorimeter may be a useful educational tool.

  2. Systems and Methods for Imaging of Falling Objects

    NASA Technical Reports Server (NTRS)

    Fallgatter, Cale (Inventor); Garrett, Tim (Inventor)

    2014-01-01

    Imaging of falling objects is described. Multiple images of a falling object can be captured substantially simultaneously using multiple cameras located at multiple angles around the falling object. An epipolar geometry of the captured images can be determined. The images can be rectified to parallelize epipolar lines of the epipolar geometry. Correspondence points between the images can be identified. At least a portion of the falling object can be digitally reconstructed using the identified correspondence points to create a digital reconstruction.

  3. Interoperability, Scaling, and the Digital Libraries Research Agenda.

    ERIC Educational Resources Information Center

    Lynch, Clifford; Garcia-Molina, Hector

    1996-01-01

    Summarizes reports and activities at the Information Infrastructure Technology and Applications workshop on digital libraries (Reston, Virginia, August 22, 1995). Defines digital library roles and identifies areas of needed research, including: interoperability; protocols for digital objects; collection management; interface design; human-computer…

  4. The 3D scanner prototype utilize object profile imaging using line laser and octave software

    NASA Astrophysics Data System (ADS)

    Nurdini, Mugi; Manunggal, Trikarsa Tirtadwipa; Samsi, Agus

    2016-11-01

    Three-dimensional scanner or 3D Scanner is a device to reconstruct the real object into digital form on a computer. 3D Scanner is a technology that is being developed, especially in developed countries, where the current 3D Scanner devices is the advanced version with a very expensive prices. This study is basically a simple prototype of 3D Scanner with a very low investment costs. 3D Scanner prototype device consists of a webcam, a rotating desk system controlled by a stepper motor and Arduino UNO, and a line laser. Objects that limit the research is the object with same radius from its center point (object pivot). Scanning is performed by using object profile imaging by line laser which is then captured by the camera and processed by a computer (image processing) using Octave software. On each image acquisition, the scanned object on a rotating desk rotated by a certain degree, so for one full turn multiple images of a number of existing side are finally obtained. Then, the profile of the entire images is extracted in order to obtain digital object dimension. Digital dimension is calibrated by length standard, called gage block. Overall dimensions are then digitally reconstructed into a three-dimensional object. Validation of the scanned object reconstruction of the original object dimensions expressed as a percentage error. Based on the results of data validation, horizontal dimension error is about 5% to 23% and vertical dimension error is about +/- 3%.

  5. SLOAN DIGITAL SKY SURVEY OBSERVATIONS OF KUIPER BELT OBJECTS: COLORS AND VARIABILITY

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ofek, Eran O.

    2012-04-10

    Colors of trans-Neptunian objects (TNOs) are used to study the evolutionary processes of bodies in the outskirts of the solar system and to test theories regarding their origin. Here I describe a search for serendipitous Sloan Digital Sky Survey (SDSS) observations of known TNOs and Centaurs. I present a catalog of SDSS photometry, colors, and astrometry of 388 measurements of 42 outer solar system objects. I find weak evidence, at the Almost-Equal-To 2{sigma} level (per trial), for a correlation between the g - r color and inclination of scattered disk objects and hot classical Kuiper Belt objects. I find amore » correlation between the g - r color and the angular momentum in the z direction of all the objects in this sample. These findings should be verified using larger samples of TNOs. Light curves as a function of phase angle are constructed for 13 objects. The steepness of the slopes of these light curves suggests that the coherent backscatter mechanism plays a major role in the reflectivity of outer solar system small objects at small phase angles. I find weak evidence for an anticorrelation, significant at the 2{sigma} confidence level (per trial), between the g-band phase-angle slope parameter and the semimajor axis, as well as the aphelion distance, of these objects (i.e., they show a more prominent 'opposition effect' at smaller distances from the Sun). However, this plausible correlation should be verified using a larger sample. I discuss the origin of this possible correlation and argue that if this correlation is real it probably indicates that 'Sedna'-like objects have a different origin than other classes of TNOs. Finally, I identify several objects with large variability amplitudes.« less

  6. The reality of virtual anthropology: Comparing digitizer and laser scan data collection methods for the quantitative assessment of the cranium.

    PubMed

    Algee-Hewitt, Bridget F B; Wheat, Amber D

    2016-05-01

    The use of geometric morphometry to study cranial variation has steadily grown in appeal over the past decade in biological anthropology. Publication trends suggest that the most popular methods for three-dimensional data acquisition involve landmark-based coordinate data collection using a digitizer. Newer laser scan approaches are seeing increasing use, owing to the benefits that densely sampled data offer. While both of these methods have their utility, research that investigates their compatibility is lacking. The purpose of this project is to compare, quantitatively, craniometrics collected with a digitizer against data extracted from laser scans using the same individuals and laboratory conditions. Three-dimensional (x,y,z) coordinates and traditional inter-landmark distances (ILDs) were obtained with a Microscribe digitizer and 360° color models produced from NextEngine laser scans for 38 adult crania representing five cemeteries from the ADBOU skeletal collection in Denmark. Variance-based tests were performed to evaluate the disagreement between data collected with a digitizer and from laser scan models. Consideration was given to differences among landmarks by type, between ILDs calculated from landmark coordinates, and in morphology for the cemetery populations. Further, the reliability of laser scan data collection was assessed by intra-observer error tests. Researchers should be aware of the potential error associated with the use of Types II and III landmarks and the limitations on reliability imposed by object-to-scanner placement. This project reveals how laser scans can provide a valuable digital archive of cranial material that can be reasonably exploited for the "virtual" collection of coordinates and the calculation of ILDs. © 2015 Wiley Periodicals, Inc.

  7. Comparison of a new digital KM screen test with conventional Hess and Lees screen tests in the mapping of ocular deviations.

    PubMed

    Thorisdottir, Rannveig Linda; Sundgren, Johanna; Sheikh, Rafi; Blohmé, Jonas; Hammar, Björn; Kjellström, Sten; Malmsjö, Malin

    2018-05-28

    To evaluate the digital KM screen computerized ocular motility test and to compare it with conventional nondigital techniques using the Hess and Lees screens. Patients with known ocular deviations and a visual acuity of at least 20/100 underwent testing using the digital KM screen and the Hess and Lees screen tests. The examination duration, the subjectively perceived difficulty, and the patient's method of choice were compared for the three tests. The accuracy of test results was compared using Bland-Altman plots between testing methods. A total of 19 patients were included. Examination with the digital KM screen test was less time-consuming than tests with the Hess and Lees screens (P < 0.001 and P = 0.003, resp., compared with the digital KM screen). Patients found the test with the digital KM screen easier to perform than the Lees screen test (P = 0.009) but of similar difficulty to the Hess screen test (P = 0.203). The majority of the patients (83%) preferred the digital KM screen test to both of the other screen methods (P = 0.008). Bland-Altman plots showed that the results obtained with all three tests were similar. The digital KM screen is accurate and time saving and provides similar results to Lees and Hess screen testing. It also has the advantage of a digital data analysis and registration. Copyright © 2018 American Association for Pediatric Ophthalmology and Strabismus. Published by Elsevier Inc. All rights reserved.

  8. The algorithm for automatic detection of the calibration object

    NASA Astrophysics Data System (ADS)

    Artem, Kruglov; Irina, Ugfeld

    2017-06-01

    The problem of the automatic image calibration is considered in this paper. The most challenging task of the automatic calibration is a proper detection of the calibration object. The solving of this problem required the appliance of the methods and algorithms of the digital image processing, such as morphology, filtering, edge detection, shape approximation. The step-by-step process of the development of the algorithm and its adopting to the specific conditions of the log cuts in the image's background is presented. Testing of the automatic calibration module was carrying out under the conditions of the production process of the logging enterprise. Through the tests the average possibility of the automatic isolating of the calibration object is 86.1% in the absence of the type 1 errors. The algorithm was implemented in the automatic calibration module within the mobile software for the log deck volume measurement.

  9. Interactive Digital e-Health Game for Heart Failure Self-Management: A Feasibility Study

    PubMed Central

    Toprac, Paul; O'Hair, Matt; Bias, Randolph; Kim, Miyong T.; Bradley, Paul; Mackert, Michael

    2016-01-01

    Abstract Objective: To develop and test the prototype of a serious digital game for improving community-dwelling older adults' heart failure (HF) knowledge and self-management behaviors. The serious game innovatively incorporates evidence-based HF guidelines with contemporary game technology. Materials and Methods: The study included three phases: development of the game prototype, its usability assessment, and evaluation of the game's functionality. Usability testing included researchers' usability assessment, followed by research personnel's observations of participants playing the game, and participants' completion of a usability survey. Next, in a pretest–post-test design, validated instruments—the Atlanta Heart Failure Knowledge Test and the Self Care for Heart Failure Index—were used to measure improvement in HF self-management knowledge and behaviors related to HF self-maintenance, self-management, and self-efficacy, respectively. A postgame survey assessed participants' perceptions of the game. Results: During usability testing, with seven participants, 100%, 100%, and 86% found the game easy to play, enjoyable, and helpful for learning about HF, respectively. In the subsequent functionality testing, with 19 participants, 89% found the game interesting, enjoyable, and easy to play. Playing the game resulted in a significant improvement in HF self-management knowledge, a nonsignificant improvement in self-reported behaviors related to HF self-maintenance, and no difference in HF self-efficacy scores. Participants with lower education level and age preferred games to any other medium for receiving information. Conclusion: It is feasible to develop a serious digital game that community-dwelling older adults with HF find both satisfying and acceptable and that can improve their self-management knowledge. PMID:27976955

  10. Evaluation of the Effect of Light and Scanning Time Delay on The Image Quality of Intra Oral Photostimulable Phosphor Plates

    PubMed Central

    Eskandarloo, Amir; Yousefi, Arman; Soheili, Setareh; Ghazikhanloo, Karim; Amini, Payam; Mohammadpoor, Haniyeh

    2017-01-01

    Background: Nowadays, digital radiography is widely used in dental practice. One of the most common types is Photo Stimulated Phosphor Plate (PSP). Objective: The aims of this experimental study were to evaluate the impacts of different combinations of storage conditions and varying delays in reading of digital images captured using PSPs. Methods: Standardized images of a step wedges were obtained using PSPs from the Digora digital systems. Plates were exposed and immediately scanned to produce the baseline gold standard. The plates were re-exposed and stored in four different storage conditions: white light, yellow light, natural light environment and dark room, then scanned after 10 and 30 minutes and 4 and 8 hours. Objective analysis was conducted by density measurements and the data were analyzed statistically using GEE test. Subjective analysis was performed by two oral and maxillofacial radiologists and the results were analyzed using McNemar’s test. Results: The results from GEE analysis show that in the natural light environment, the densities in 10 minutes did not differ from the baseline. The mean densities decreased significantly during the time in all environments. The mean densities in step 2 for the dark room environment decreased with a slighter slope in comparison to yellow environment significantly. Conclusion: PSP images showed significant decrease in the density in plates scanned for 10 minutes or longer after exposure which may not be detected clinically. The yellow light environment had a different impact on the quality of PSP images. The spatial resolution did not change significantly with time. PMID:29430262

  11. Object-oriented and pixel-based classification approach for land cover using airborne long-wave infrared hyperspectral data

    NASA Astrophysics Data System (ADS)

    Marwaha, Richa; Kumar, Anil; Kumar, Arumugam Senthil

    2015-01-01

    Our primary objective was to explore a classification algorithm for thermal hyperspectral data. Minimum noise fraction is applied to thermal hyperspectral data and eight pixel-based classifiers, i.e., constrained energy minimization, matched filter, spectral angle mapper (SAM), adaptive coherence estimator, orthogonal subspace projection, mixture-tuned matched filter, target-constrained interference-minimized filter, and mixture-tuned target-constrained interference minimized filter are tested. The long-wave infrared (LWIR) has not yet been exploited for classification purposes. The LWIR data contain emissivity and temperature information about an object. A highest overall accuracy of 90.99% was obtained using the SAM algorithm for the combination of thermal data with a colored digital photograph. Similarly, an object-oriented approach is applied to thermal data. The image is segmented into meaningful objects based on properties such as geometry, length, etc., which are grouped into pixels using a watershed algorithm and an applied supervised classification algorithm, i.e., support vector machine (SVM). The best algorithm in the pixel-based category is the SAM technique. SVM is useful for thermal data, providing a high accuracy of 80.00% at a scale value of 83 and a merge value of 90, whereas for the combination of thermal data with a colored digital photograph, SVM gives the highest accuracy of 85.71% at a scale value of 82 and a merge value of 90.

  12. Teaching Dental Students to Understand the Temporomandibular Joint Using MRI: Comparison of Conventional and Digital Learning Methods.

    PubMed

    Arús, Nádia A; da Silva, Átila M; Duarte, Rogério; da Silveira, Priscila F; Vizzotto, Mariana B; da Silveira, Heraldo L D; da Silveira, Heloisa E D

    2017-06-01

    The aims of this study were to evaluate and compare the performance of dental students in interpreting the temporomandibular joint (TMJ) with magnetic resonance imaging (MRI) scans using two learning methods (conventional and digital interactive learning) and to examine the usability of the digital learning object (DLO). The DLO consisted of tutorials about MRI and anatomic and functional aspects of the TMJ. In 2014, dental students in their final year of study who were enrolled in the elective "MRI Interpretation of the TMJ" course comprised the study sample. After exclusions for nonattendance and other reasons, 29 of the initial 37 students participated in the study, for a participation rate of 78%. The participants were divided into two groups: a digital interactive learning group (n=14) and a conventional learning group (n=15). Both methods were assessed by an objective test applied before and after training and classes. Aspects such as support and training requirements, complexity, and consistency of the DLO were also evaluated using the System Usability Scale (SUS). A significant between-group difference in the posttest results was found, with the conventional learning group scoring better than the DLO group, indicated by mean scores of 9.20 and 8.11, respectively, out of 10. However, when the pretest and posttest results were compared, both groups showed significantly improved performance. The SUS score was 89, which represented a high acceptance of the DLO by the users. The students who used the conventional method of learning showed superior performance in interpreting the TMJ using MRI compared to the group that used digital interactive learning.

  13. Could Digital PCR Be an Alternative as a Non-Invasive Prenatal Test for Trisomy 21: A Proof of Concept Study

    PubMed Central

    El Khattabi, Laïla Allach; Rouillac-Le Sciellour, Christelle; Le Tessier, Dominique; Luscan, Armelle; Coustier, Audrey; Porcher, Raphael; Bhouri, Rakia; Nectoux, Juliette; Sérazin, Valérie; Quibel, Thibaut; Mandelbrot, Laurent; Tsatsaris, Vassilis

    2016-01-01

    Objective NIPT for fetal aneuploidy by digital PCR has been hampered by the large number of PCR reactions needed to meet statistical requirements, preventing clinical application. Here, we designed an octoplex droplet digital PCR (ddPCR) assay which allows increasing the number of available targets and thus overcomes statistical obstacles. Method After technical optimization of the multiplex PCR on mixtures of trisomic and euploid DNA, we performed a validation study on samples of plasma DNA from 213 pregnant women. Molecular counting of circulating cell-free DNA was performed using a mix of hydrolysis probes targeting chromosome 21 and a reference chromosome. Results The results of our validation experiments showed that ddPCR detected trisomy 21 even when the sample’s trisomic DNA content is as low as 5%. In a validation study of plasma samples from 213 pregnant women, ddPCR discriminated clearly between the trisomy 21 and the euploidy groups. Conclusion Our results demonstrate that digital PCR can meet the requirements for non-invasive prenatal testing of trisomy 21. This approach is technically simple, relatively cheap, easy to implement in a diagnostic setting and compatible with ethical concerns regarding access to nucleotide sequence information. These advantages make it a potential technique of choice for population-wide screening for trisomy 21 in pregnant women. PMID:27167625

  14. Objective measurement of erythema in psoriasis using digital color photography with color calibration.

    PubMed

    Raina, A; Hennessy, R; Rains, M; Allred, J; Hirshburg, J M; Diven, D G; Markey, M K

    2016-08-01

    Traditional metrics for evaluating the severity of psoriasis are subjective, which complicates efforts to measure effective treatments in clinical trials. We collected images of psoriasis plaques and calibrated the coloration of the images according to an included color card. Features were extracted from the images and used to train a linear discriminant analysis classifier with cross-validation to automatically classify the degree of erythema. The results were tested against numerical scores obtained by a panel of dermatologists using a standard rating system. Quantitative measures of erythema based on the digital color images showed good agreement with subjective assessment of erythema severity (κ = 0.4203). The color calibration process improved the agreement from κ = 0.2364 to κ = 0.4203. We propose a method for the objective measurement of the psoriasis severity parameter of erythema and show that the calibration process improved the results. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  15. Single-shot color fringe projection for three-dimensional shape measurement of objects with discontinuities.

    PubMed

    Dai, Meiling; Yang, Fujun; He, Xiaoyuan

    2012-04-20

    A simple but effective fringe projection profilometry is proposed to measure 3D shape by using one snapshot color sinusoidal fringe pattern. One color fringe pattern encoded with a sinusoidal fringe (as red component) and one uniform intensity pattern (as blue component) is projected by a digital video projector, and the deformed fringe pattern is recorded by a color CCD camera. The captured color fringe pattern is separated into its RGB components and division operation is applied to red and blue channels to reduce the variable reflection intensity. Shape information of the tested object is decoded by applying an arcsine algorithm on the normalized fringe pattern with subpixel resolution. In the case of fringe discontinuities caused by height steps, or spatially isolated surfaces, the separated blue component is binarized and used for correcting the phase demodulation. A simple and robust method is also introduced to compensate for nonlinear intensity response of the digital video projector. The experimental results demonstrate the validity of the proposed method.

  16. Comparison of Two Simplification Methods for Shoreline Extraction from Digital Orthophoto Images

    NASA Astrophysics Data System (ADS)

    Bayram, B.; Sen, A.; Selbesoglu, M. O.; Vārna, I.; Petersons, P.; Aykut, N. O.; Seker, D. Z.

    2017-11-01

    The coastal ecosystems are very sensitive to external influences. Coastal resources such as sand dunes, coral reefs and mangroves has vital importance to prevent coastal erosion. Human based effects also threats the coastal areas. Therefore, the change of coastal areas should be monitored. Up-to-date, accurate shoreline information is indispensable for coastal managers and decision makers. Remote sensing and image processing techniques give a big opportunity to obtain reliable shoreline information. In the presented study, NIR bands of seven 1:5000 scaled digital orthophoto images of Riga Bay-Latvia have been used. The Object-oriented Simple Linear Clustering method has been utilized to extract shoreline of Riga Bay. Bend and Douglas-Peucker methods have been used to simplify the extracted shoreline to test the effect of both methods. Photogrammetrically digitized shoreline has been taken as reference data to compare obtained results. The accuracy assessment has been realised by Digital Shoreline Analysis tool. As a result, the achieved shoreline by the Bend method has been found closer to the extracted shoreline with Simple Linear Clustering method.

  17. Enhancement of digital radiography image quality using a convolutional neural network.

    PubMed

    Sun, Yuewen; Li, Litao; Cong, Peng; Wang, Zhentao; Guo, Xiaojing

    2017-01-01

    Digital radiography system is widely used for noninvasive security check and medical imaging examination. However, the system has a limitation of lower image quality in spatial resolution and signal to noise ratio. In this study, we explored whether the image quality acquired by the digital radiography system can be improved with a modified convolutional neural network to generate high-resolution images with reduced noise from the original low-quality images. The experiment evaluated on a test dataset, which contains 5 X-ray images, showed that the proposed method outperformed the traditional methods (i.e., bicubic interpolation and 3D block-matching approach) as measured by peak signal to noise ratio (PSNR) about 1.3 dB while kept highly efficient processing time within one second. Experimental results demonstrated that a residual to residual (RTR) convolutional neural network remarkably improved the image quality of object structural details by increasing the image resolution and reducing image noise. Thus, this study indicated that applying this RTR convolutional neural network system was useful to improve image quality acquired by the digital radiography system.

  18. H1 antihistamines and driving.

    PubMed

    Popescu, Florin Dan

    2008-01-01

    Driving performances depend on cognitive, psychomotor and perception functions. The CNS adverse effects of some H1 antihistamines can alter the patient ability to drive. Data from studies using standardized objective cognitive and psychomotor tests (Choice Reaction Time, Critical Flicker Fusion. Digital Symbol Substitution Test), functional brain imaging (Positron Emission Tomography, functional Magnetic Resonance Imaging), neurophysiological studies (Multiple Sleep Latency Test, auditory and visual evoked potentials), experimental simulated driving (driving simulators) and real driving studies (the Highway Driving Test, with the evaluation of the Standard Deviation Lateral Position, and the Car Following Test, with the measurement of the Brake Reaction Time) must be discussed in order to classify a H1 antihistamine as a true non-sedating one.

  19. H1 antihistamines and driving

    PubMed Central

    Florin-Dan, Popescu

    2008-01-01

    Driving performances depend on cognitive, psychomotor and perception functions. The CNS adverse effects of some H1 antihistamines can alter the patient ability to drive. Data from studies using standardized objective cognitive and psychomotor tests (Choice Reaction Time, Critical Flicker Fusion, Digital Symbol Substitution Test), functional brain imaging (Positron Emission Tomography, functional Magnetic Resonance Imaging), neurophysiological studies (Multiple Sleep Latency Test, auditory and visual evoked potentials), experimental simulated driving (driving simulators) and real driving studies (the Highway Driving Test, with the evaluation of the Standard Deviation Lateral Position, and the Car Following Test, with the measurement of the Brake Reaction Time) must be discussed in order to classify a H1 antihistamine as a true non-sedating one. PMID:20108503

  20. Workflows for ingest of research data into digital archives - tests with Archivematica

    NASA Astrophysics Data System (ADS)

    Kirchner, I.; Bertelmann, R.; Gebauer, P.; Hasler, T.; Hirt, M.; Klump, J. F.; Peters-Kotting, W.; Rusch, B.; Ulbricht, D.

    2013-12-01

    Publication of research data and future re-use of measured data require the long-term preservation of digital objects. The ISO OAIS reference model defines responsibilities for long-term preservation of digital objects and although there is software available to support preservation of digital data, there are still problems remaining to be solved. A key task in preservation is to make the datasets ready for ingest into the archive, which is called the creation of Submission Information Packages (SIPs) in the OAIS model. This includes the creation of appropriate preservation metadata. Scientists need to be trained to deal with different types of data and to heighten their awareness for quality metadata. Other problems arise during the assembly of SIPs and during ingest into the archive because file format validators may produce conflicting output for identical data files and these conflicts are difficult to resolve automatically. Also, validation and identification tools are notorious for their poor performance. In the project EWIG Zuse-Institute Berlin acts as an infrastructure facility, while the Institute for Meteorology at FU Berlin and the German research Centre for Geosciences GFZ act as two different data producers. The aim of the project is to develop workflows for the transfer of research data into digital archives and the future re-use of data from long-term archives with emphasis on data from the geosciences. The technical work is supplemented by interviews with data practitioners at several institutions to identify problems in digital preservation workflows and by the development of university teaching materials to train students in the curation of research data and metadata. The free and open-source software Archivematica [1] is used as digital preservation system. The creation and ingest of SIPs has to meet several archival standards and be compatible to the Metadata Encoding and Transmission Standard (METS). The two data producers use different software in their workflows to test the assembly of SIPs and ingest of SIPs into the archive. GFZ Potsdam uses a combination of eSciDoc [2], panMetaDocs [3], and bagit [4] to collect research data and assemble SIPs for ingest into Archivematica, while the Institute for Meteorology at FU Berlin evaluates a variety of software solutions to describe data and publications and to generate SIPs. [1] http://www.archivematica.org [2] http://www.escidoc.org [3] http://panmetadocs.sf.net [4] http://sourceforge.net/projects/loc-xferutils/

  1. [Digital learning object for diagnostic reasoning in nursing applied to the integumentary system].

    PubMed

    da Costa, Cecília Passos Vaz; Luz, Maria Helena Barros Araújo

    2015-12-01

    To describe the creation of a digital learning object for diagnostic reasoning in nursing applied to the integumentary system at a public university of Piaui. A methodological study applied to technological production based on the pedagogical framework of problem-based learning. The methodology for creating the learning object observed the stages of analysis, design, development, implementation and evaluation recommended for contextualized instructional design. The revised taxonomy of Bloom was used to list the educational goals. The four modules of the developed learning object were inserted into the educational platform Moodle. The theoretical assumptions allowed the design of an important online resource that promotes effective learning in the scope of nursing education. This study should add value to nursing teaching practices through the use of digital learning objects for teaching diagnostic reasoning applied to skin and skin appendages.

  2. Digital holographic microscopy combined with optical tweezers

    NASA Astrophysics Data System (ADS)

    Cardenas, Nelson; Yu, Lingfeng; Mohanty, Samarendra K.

    2011-02-01

    While optical tweezers have been widely used for the manipulation and organization of microscopic objects in three dimensions, observing the manipulated objects along axial direction has been quite challenging. In order to visualize organization and orientation of objects along axial direction, we report development of a Digital holographic microscopy combined with optical tweezers. Digital holography is achieved by use of a modified Mach-Zehnder interferometer with digital recording of interference pattern of the reference and sample laser beams by use of a single CCD camera. In this method, quantitative phase information is retrieved dynamically with high temporal resolution, only limited by frame rate of the CCD. Digital focusing, phase-unwrapping as well as online analysis and display of the quantitative phase images was performed on a software developed on LabView platform. Since phase changes observed in DHOT is very sensitive to optical thickness of trapped volume, estimation of number of particles trapped in the axial direction as well as orientation of non-spherical objects could be achieved with high precision. Since in diseases such as malaria and diabetics, change in refractive index of red blood cells occurs, this system can be employed to map such disease-specific changes in biological samples upon immobilization with optical tweezers.

  3. Datasets2Tools, repository and search engine for bioinformatics datasets, tools and canned analyses

    PubMed Central

    Torre, Denis; Krawczuk, Patrycja; Jagodnik, Kathleen M.; Lachmann, Alexander; Wang, Zichen; Wang, Lily; Kuleshov, Maxim V.; Ma’ayan, Avi

    2018-01-01

    Biomedical data repositories such as the Gene Expression Omnibus (GEO) enable the search and discovery of relevant biomedical digital data objects. Similarly, resources such as OMICtools, index bioinformatics tools that can extract knowledge from these digital data objects. However, systematic access to pre-generated ‘canned’ analyses applied by bioinformatics tools to biomedical digital data objects is currently not available. Datasets2Tools is a repository indexing 31,473 canned bioinformatics analyses applied to 6,431 datasets. The Datasets2Tools repository also contains the indexing of 4,901 published bioinformatics software tools, and all the analyzed datasets. Datasets2Tools enables users to rapidly find datasets, tools, and canned analyses through an intuitive web interface, a Google Chrome extension, and an API. Furthermore, Datasets2Tools provides a platform for contributing canned analyses, datasets, and tools, as well as evaluating these digital objects according to their compliance with the findable, accessible, interoperable, and reusable (FAIR) principles. By incorporating community engagement, Datasets2Tools promotes sharing of digital resources to stimulate the extraction of knowledge from biomedical research data. Datasets2Tools is freely available from: http://amp.pharm.mssm.edu/datasets2tools. PMID:29485625

  4. Datasets2Tools, repository and search engine for bioinformatics datasets, tools and canned analyses.

    PubMed

    Torre, Denis; Krawczuk, Patrycja; Jagodnik, Kathleen M; Lachmann, Alexander; Wang, Zichen; Wang, Lily; Kuleshov, Maxim V; Ma'ayan, Avi

    2018-02-27

    Biomedical data repositories such as the Gene Expression Omnibus (GEO) enable the search and discovery of relevant biomedical digital data objects. Similarly, resources such as OMICtools, index bioinformatics tools that can extract knowledge from these digital data objects. However, systematic access to pre-generated 'canned' analyses applied by bioinformatics tools to biomedical digital data objects is currently not available. Datasets2Tools is a repository indexing 31,473 canned bioinformatics analyses applied to 6,431 datasets. The Datasets2Tools repository also contains the indexing of 4,901 published bioinformatics software tools, and all the analyzed datasets. Datasets2Tools enables users to rapidly find datasets, tools, and canned analyses through an intuitive web interface, a Google Chrome extension, and an API. Furthermore, Datasets2Tools provides a platform for contributing canned analyses, datasets, and tools, as well as evaluating these digital objects according to their compliance with the findable, accessible, interoperable, and reusable (FAIR) principles. By incorporating community engagement, Datasets2Tools promotes sharing of digital resources to stimulate the extraction of knowledge from biomedical research data. Datasets2Tools is freely available from: http://amp.pharm.mssm.edu/datasets2tools.

  5. An Objective Measure of Noseband Tightness and Its Measurement Using a Novel Digital Tightness Gauge.

    PubMed

    Doherty, Orla; Conway, Thomas; Conway, Richard; Murray, Gerard; Casey, Vincent

    2017-01-01

    Noseband tightness is difficult to assess in horses participating in equestrian sports such as dressage, show jumping and three-day-eventing. There is growing concern that nosebands are commonly tightened to such an extent as to restrict normal equine behaviour and possibly cause injury. In the absence of a clear agreed definition of noseband tightness, a simple model of the equine nose-noseband interface environment was developed in order to guide further studies in this area. The normal force component of the noseband tensile force was identified as the key contributor to sub-noseband tissue compression. The model was used to inform the design of a digital tightness gauge which could reliably measure the normal force component of the noseband tensile force. A digital tightness gauge was developed to measure this parameter under nosebands fitted to bridled horses. Results are presented for field tests using two prototype designs. Prototype version three was used in field trial 1 (n = 15, frontal nasal plane sub-noseband site). Results of this trial were used to develop an ergonomically designed prototype, version 4, which was tested in a second field trial (n = 12, frontal nasal plane and lateral sub-noseband site). Nosebands were set to three tightness settings in each trial as judged by a single rater using an International Society for Equitation Science (ISES) taper gauge. Normal forces in the range 7-95 N were recorded at the frontal nasal plane while a lower range 1-28 N was found at the lateral site for the taper gauge range used in the trials. The digital tightness gauge was found to be simple to use, reliable, and safe and its use did not agitate the animals in any discernable way. A simple six point tightness scale is suggested to aid regulation implementation and the control of noseband tightness using normal force measurement as the objective tightness discriminant.

  6. Feasibility study for locating archaeological village sites by satellite remote sensing techniques. [multispectral photography of Alaska

    NASA Technical Reports Server (NTRS)

    Cook, J. P. (Principal Investigator); Stringer, W. J.

    1974-01-01

    The author has identified the following significant results. The objective is to determine the feasibility of detecting large Alaskan archaeological sites by satellite remote sensing techniques and mapping such sites. The approach used is to develop digital multispectral signatures of dominant surface features including vegetation, exposed soils and rock, hydrological patterns and known archaeological sites. ERTS-1 scenes are then printed out digitally in a map-like array with a letter reflecting the most appropriate classification representing each pixel. Preliminary signatures were developed and tested. It was determined that there was a need to tighten up the archaeological site signature by developing accurate signatures for all naturally-occurring vegetation and surface conditions in the vicinity of the test area. These second generation signatures have been tested by means of computer printouts and classified tape displays on the University of Alaska CDU-200 and by comparison with aerial photography. It has been concluded that the archaeological signatures now in use are as good as can be developed. Plans are to print out signatures for the entire test area and locate on topographic maps the likely locations of archaeological sites within the test area.

  7. Digital imaging and remote sensing image generator (DIRSIG) as applied to NVESD sensor performance modeling

    NASA Astrophysics Data System (ADS)

    Kolb, Kimberly E.; Choi, Hee-sue S.; Kaur, Balvinder; Olson, Jeffrey T.; Hill, Clayton F.; Hutchinson, James A.

    2016-05-01

    The US Army's Communications Electronics Research, Development and Engineering Center (CERDEC) Night Vision and Electronic Sensors Directorate (referred to as NVESD) is developing a virtual detection, recognition, and identification (DRI) testing methodology using simulated imagery as a means of augmenting the field testing component of sensor performance evaluation, which is expensive, resource intensive, time consuming, and limited to the available target(s) and existing atmospheric visibility and environmental conditions at the time of testing. Existing simulation capabilities such as the Digital Imaging Remote Sensing Image Generator (DIRSIG) and NVESD's Integrated Performance Model Image Generator (NVIPM-IG) can be combined with existing detection algorithms to reduce cost/time, minimize testing risk, and allow virtual/simulated testing using full spectral and thermal object signatures, as well as those collected in the field. NVESD has developed an end-to-end capability to demonstrate the feasibility of this approach. Simple detection algorithms have been used on the degraded images generated by NVIPM-IG to determine the relative performance of the algorithms on both DIRSIG-simulated and collected images. Evaluating the degree to which the algorithm performance agrees between simulated versus field collected imagery is the first step in validating the simulated imagery procedure.

  8. Digital signal conditioning for flight test instrumentation

    NASA Technical Reports Server (NTRS)

    Bever, Glenn A.

    1991-01-01

    An introduction to digital measurement processes on aircraft is provided. Flight test instrumentation systems are rapidly evolving from analog-intensive to digital intensive systems, including the use of onboard digital computers. The topics include measurements that are digital in origin, as well as sampling, encoding, transmitting, and storing data. Particular emphasis is placed on modern avionic data bus architectures and what to be aware of when extracting data from them. Examples of data extraction techniques are given. Tradeoffs between digital logic families, trends in digital development, and design testing techniques are discussed. An introduction to digital filtering is also covered.

  9. STS-48 Pilot Reightler on OV-103's aft flight deck poses for ESC photo

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-48 Pilot Kenneth S. Reightler, Jr, positioned under overhead window W8, poses for an electronic still camera (ESC) photo on the aft flight deck of the earth-orbiting Discovery, Orbiter Vehicle (OV) 103. Crewmembers were testing the ESC as part of Development Test Objective (DTO) 648, Electronic Still Photography. The digital image was stored on a removable hard disk or small optical disk, and could be converted to a format suitable for downlink transmission. The ESC is making its initial appearance on this Space Shuttle mission.

  10. Using Digital Learning Objects to Introduce Students to the Nature of Models and the Nature of Matter

    ERIC Educational Resources Information Center

    Gustafson, Brenda; Mahaffy, Peter; Martin, Brian

    2011-01-01

    This article reports a subset of findings from a larger study centered on designing a series of six digital learning objects to help Grade 5 (age 10-12) students begin to consider the nature of models (understood as the physical or mental representation of objects, phenomena, or processes), the particle nature of matter, and the behavior of…

  11. Automatic testing and assessment of neuroanatomy using a digital brain atlas: method and development of computer- and mobile-based applications.

    PubMed

    Nowinski, Wieslaw L; Thirunavuukarasuu, Arumugam; Ananthasubramaniam, Anand; Chua, Beng Choon; Qian, Guoyu; Nowinska, Natalia G; Marchenko, Yevgen; Volkau, Ihar

    2009-10-01

    Preparation of tests and student's assessment by the instructor are time consuming. We address these two tasks in neuroanatomy education by employing a digital media application with a three-dimensional (3D), interactive, fully segmented, and labeled brain atlas. The anatomical and vascular models in the atlas are linked to Terminologia Anatomica. Because the cerebral models are fully segmented and labeled, our approach enables automatic and random atlas-derived generation of questions to test location and naming of cerebral structures. This is done in four steps: test individualization by the instructor, test taking by the students at their convenience, automatic student assessment by the application, and communication of the individual assessment to the instructor. A computer-based application with an interactive 3D atlas and a preliminary mobile-based application were developed to realize this approach. The application works in two test modes: instructor and student. In the instructor mode, the instructor customizes the test by setting the scope of testing and student performance criteria, which takes a few seconds. In the student mode, the student is tested and automatically assessed. Self-testing is also feasible at any time and pace. Our approach is automatic both with respect to test generation and student assessment. It is also objective, rapid, and customizable. We believe that this approach is novel from computer-based, mobile-based, and atlas-assisted standpoints.

  12. DAM-ing the Digital Flood

    ERIC Educational Resources Information Center

    Raths, David

    2008-01-01

    With the widespread digitization of art, photography, and music, plus the introduction of streaming video, many colleges and universities are realizing that they must develop or purchase systems to preserve their school's digitized objects; that they must create searchable databases so that researchers can find and share copies of digital files;…

  13. Digital Initiatives and Metadata Use in Thailand

    ERIC Educational Resources Information Center

    SuKantarat, Wichada

    2008-01-01

    Purpose: This paper aims to provide information about various digital initiatives in libraries in Thailand and especially use of Dublin Core metadata in cataloguing digitized objects in academic and government digital databases. Design/methodology/approach: The author began researching metadata use in Thailand in 2003 and 2004 while on sabbatical…

  14. Automatic Spiral Analysis for Objective Assessment of Motor Symptoms in Parkinson's Disease.

    PubMed

    Memedi, Mevludin; Sadikov, Aleksander; Groznik, Vida; Žabkar, Jure; Možina, Martin; Bergquist, Filip; Johansson, Anders; Haubenberger, Dietrich; Nyholm, Dag

    2015-09-17

    A challenge for the clinical management of advanced Parkinson's disease (PD) patients is the emergence of fluctuations in motor performance, which represents a significant source of disability during activities of daily living of the patients. There is a lack of objective measurement of treatment effects for in-clinic and at-home use that can provide an overview of the treatment response. The objective of this paper was to develop a method for objective quantification of advanced PD motor symptoms related to off episodes and peak dose dyskinesia, using spiral data gathered by a touch screen telemetry device. More specifically, the aim was to objectively characterize motor symptoms (bradykinesia and dyskinesia), to help in automating the process of visual interpretation of movement anomalies in spirals as rated by movement disorder specialists. Digitized upper limb movement data of 65 advanced PD patients and 10 healthy (HE) subjects were recorded as they performed spiral drawing tasks on a touch screen device in their home environment settings. Several spatiotemporal features were extracted from the time series and used as inputs to machine learning methods. The methods were validated against ratings on animated spirals scored by four movement disorder specialists who visually assessed a set of kinematic features and the motor symptom. The ability of the method to discriminate between PD patients and HE subjects and the test-retest reliability of the computed scores were also evaluated. Computed scores correlated well with mean visual ratings of individual kinematic features. The best performing classifier (Multilayer Perceptron) classified the motor symptom (bradykinesia or dyskinesia) with an accuracy of 84% and area under the receiver operating characteristics curve of 0.86 in relation to visual classifications of the raters. In addition, the method provided high discriminating power when distinguishing between PD patients and HE subjects as well as had good test-retest reliability. This study demonstrated the potential of using digital spiral analysis for objective quantification of PD-specific and/or treatment-induced motor symptoms.

  15. A Multidimensional Tool Based on the eHealth Literacy Framework: Development and Initial Validity Testing of the eHealth Literacy Questionnaire (eHLQ)

    PubMed Central

    Karnoe, Astrid; Furstrand, Dorthe; Batterham, Roy; Christensen, Karl Bang; Elsworth, Gerald; Osborne, Richard H

    2018-01-01

    Background For people to be able to access, understand, and benefit from the increasing digitalization of health services, it is critical that services are provided in a way that meets the user’s needs, resources, and competence. Objective The objective of the study was to develop a questionnaire that captures the 7-dimensional eHealth Literacy Framework (eHLF). Methods Draft items were created in parallel in English and Danish. The items were generated from 450 statements collected during the conceptual development of eHLF. In all, 57 items (7 to 9 items per scale) were generated and adjusted after cognitive testing. Items were tested in 475 people recruited from settings in which the scale was intended to be used (community and health care settings) and including people with a range of chronic conditions. Measurement properties were assessed using approaches from item response theory (IRT) and classical test theory (CTT) such as confirmatory factor analysis (CFA) and reliability using composite scale reliability (CSR); potential bias due to age and sex was evaluated using differential item functioning (DIF). Results CFA confirmed the presence of the 7 a priori dimensions of eHLF. Following item analysis, a 35-item 7-scale questionnaire was constructed, covering (1) using technology to process health information (5 items, CSR=.84), (2) understanding of health concepts and language (5 items, CSR=.75), (3) ability to actively engage with digital services (5 items, CSR=.86), (4) feel safe and in control (5 items, CSR=.87), (5) motivated to engage with digital services (5 items, CSR=.84), (6) access to digital services that work (6 items, CSR=.77), and (7) digital services that suit individual needs (4 items, CSR=.85). A 7-factor CFA model, using small-variance priors for cross-loadings and residual correlations, had a satisfactory fit (posterior productive P value: .27, 95% CI for the difference between the observed and replicated chi-square values: −63.7 to 133.8). The CFA showed that all items loaded strongly on their respective factors. The IRT analysis showed that no items were found to have disordered thresholds. For most scales, discriminant validity was acceptable; however, 2 pairs of dimensions were highly correlated; dimensions 1 and 5 (r=.95), and dimensions 6 and 7 (r=.96). All dimensions were retained because of strong content differentiation and potential causal relationships between these dimensions. There is no evidence of DIF. Conclusions The eHealth Literacy Questionnaire (eHLQ) is a multidimensional tool based on a well-defined a priori eHLF framework with robust properties. It has satisfactory evidence of construct validity and reliable measurement across a broad range of concepts (using both CTT and IRT traditions) in various groups. It is designed to be used to understand and evaluate people’s interaction with digital health services. PMID:29434011

  16. Fabrication and test of digital output interface devices for gas turbine electronic controls

    NASA Technical Reports Server (NTRS)

    Newirth, D. M.; Koenig, E. W.

    1978-01-01

    A program was conducted to develop an innovative digital output interface device, a digital effector with optical feedback of the fuel metering valve position, for future electronic controls for gas turbine engines. A digital effector (on-off solenoids driven directly by on-off signals from a digital electronic controller) with optical position feedback was fabricated, coupled with the fuel metering valve, and tested under simulated engine operating conditions. The testing indicated that a digital effector with optical position feedback is a suitable candidate, with proper development for future digital electronic gas turbine controls. The testing also identified several problem areas which would have to be overcome in a final production configuration.

  17. A Framework for Realistic Modeling and Display of Object Surface Appearance

    NASA Astrophysics Data System (ADS)

    Darling, Benjamin A.

    With advances in screen and video hardware technology, the type of content presented on computers has progressed from text and simple shapes to high-resolution photographs, photorealistic renderings, and high-definition video. At the same time, there have been significant advances in the area of content capture, with the development of devices and methods for creating rich digital representations of real-world objects. Unlike photo or video capture, which provide a fixed record of the light in a scene, these new technologies provide information on the underlying properties of the objects, allowing their appearance to be simulated for novel lighting and viewing conditions. These capabilities provide an opportunity to continue the computer display progression, from high-fidelity image presentations to digital surrogates that recreate the experience of directly viewing objects in the real world. In this dissertation, a framework was developed for representing objects with complex color, gloss, and texture properties and displaying them onscreen to appear as if they are part of the real-world environment. At its core, there is a conceptual shift from a traditional image-based display workflow to an object-based one. Instead of presenting the stored patterns of light from a scene, the objective is to reproduce the appearance attributes of a stored object by simulating its dynamic patterns of light for the real viewing and lighting geometry. This is accomplished using a computational approach where the physical light sources are modeled and the observer and display screen are actively tracked. Surface colors are calculated for the real spectral composition of the illumination with a custom multispectral rendering pipeline. In a set of experiments, the accuracy of color and gloss reproduction was evaluated by measuring the screen directly with a spectroradiometer. Gloss reproduction was assessed by comparing gonio measurements of the screen output to measurements of the real samples in the same measurement configuration. A chromatic adaptation experiment was performed to evaluate color appearance in the framework and explore the factors that contribute to differences when viewing self-luminous displays as opposed to reflective objects. A set of sample applications was developed to demonstrate the potential utility of the object display technology for digital proofing, psychophysical testing, and artwork display.

  18. If an antelope is a document, then a rock is data: preserving earth science samples for the future

    NASA Astrophysics Data System (ADS)

    Ramdeen, S.

    2015-12-01

    As discussed in seminal works by Briet (1951) and Buckland (1998), physical objects can be considered documents when given specific context. In the case of an antelope, in the wild it's an animal, in a zoo it's a document. It is the primary source of information, specifically when it is made an object of study. When discussing earth science data, we may think about numbers in a spreadsheet or verbal descriptions of a rock. But what about physical materials such as cores, cuttings, fossils, and other tangible objects? The most recent version of the American Geophysical Union's data position statement states data preservation and management policies should apply to both "digital data and physical objects"[1]. If an antelope is a document, than isn't a rock a form of data? Like books in a library or items in a museum, these objects require surrogates (digital or analog) that allow researchers to access and retrieve them. Once these scientific objects are acquired, researchers can process the information they contain. Unlike books, and some museum materials, most earth science objects cannot yet be completely replaced by digital surrogates. A fossil may be scanned, but the original is needed for chemical testing and ultimately for 'not yet developed' processes of scientific analysis. These objects along with their metadata or other documentation become scientific data when they are used in research. Without documentation of key information (i.e. the location where it was collected) these objects may lose their scientific value. This creates a complex situation where we must preserve the object, its metadata, and the connection between them. These factors are important as we consider the future of earth science data, our definitions of what constitutes scientific data, as well as our data preservation and management practices. This talk will discuss current initiatives within the earth science communities (EarthCube's EC3 and iSamples; USGS's data preservation program; etc.) and within the communities of information science. As practitioners, these librarians, information scientists, and archivists work on similar issues and can offer practices and theories that might help us 'future proof' physical earth science records. [1] http://sciencepolicy.agu.org/draft-data-position-statement-comment

  19. Standardization of End-to-End Performance of Digital Video Teleconferencing/Video Telephony Systems

    DTIC Science & Technology

    1991-12-01

    SYSTEM 3-1 end-to-end video transmission system including both firmly specified and peripheral flexible functions. The format converter changes either...which manifests itself in both subjective evaluations and objective tests. The relative importance of performance parameters is likely to change with...conventional analog performance parameters to be largely independent of bit rate, and only slightly changed between different codec models. The

  20. Full-frame, high-speed 3D shape and deformation measurements using stereo-digital image correlation and a single color high-speed camera

    NASA Astrophysics Data System (ADS)

    Yu, Liping; Pan, Bing

    2017-08-01

    Full-frame, high-speed 3D shape and deformation measurement using stereo-digital image correlation (stereo-DIC) technique and a single high-speed color camera is proposed. With the aid of a skillfully designed pseudo stereo-imaging apparatus, color images of a test object surface, composed of blue and red channel images from two different optical paths, are recorded by a high-speed color CMOS camera. The recorded color images can be separated into red and blue channel sub-images using a simple but effective color crosstalk correction method. These separated blue and red channel sub-images are processed by regular stereo-DIC method to retrieve full-field 3D shape and deformation on the test object surface. Compared with existing two-camera high-speed stereo-DIC or four-mirror-adapter-assisted singe-camera high-speed stereo-DIC, the proposed single-camera high-speed stereo-DIC technique offers prominent advantages of full-frame measurements using a single high-speed camera but without sacrificing its spatial resolution. Two real experiments, including shape measurement of a curved surface and vibration measurement of a Chinese double-side drum, demonstrated the effectiveness and accuracy of the proposed technique.

  1. Image Segmentation Using Minimum Spanning Tree

    NASA Astrophysics Data System (ADS)

    Dewi, M. P.; Armiati, A.; Alvini, S.

    2018-04-01

    This research aim to segmented the digital image. The process of segmentation is to separate the object from the background. So the main object can be processed for the other purposes. Along with the development of technology in digital image processing application, the segmentation process becomes increasingly necessary. The segmented image which is the result of the segmentation process should accurate due to the next process need the interpretation of the information on the image. This article discussed the application of minimum spanning tree on graph in segmentation process of digital image. This method is able to separate an object from the background and the image will change to be the binary images. In this case, the object that being the focus is set in white, while the background is black or otherwise.

  2. Miniature objective lens for array digital pathology: design improvement based on clinical evaluation

    NASA Astrophysics Data System (ADS)

    McCall, Brian; Pierce, Mark; Graviss, Edward A.; Richards-Kortum, Rebecca R.; Tkaczyk, Tomasz S.

    2016-03-01

    A miniature objective designed for digital detection of Mycobacterium tuberculosis (MTB) was evaluated for diagnostic accuracy. The objective was designed for array microscopy, but fabricated and evaluated at this stage of development as a single objective. The counts and diagnoses of patient samples were directly compared for digital detection and standard microscopy. The results were found to be correlated and highly concordant. The evaluation of this lens by direct comparison to standard fluorescence sputum smear microscopy presented unique challenges and led to some new insights in the role played by the system parameters of the microscope. The design parameters and how they were developed are reviewed in light of these results. New system parameters are proposed with the goal of easing the challenges of evaluating the miniature objective and maintaining the optical performance that produced the agreeable results presented without over-optimizing. A new design is presented that meets and exceeds these criteria.

  3. Automatic target recognition apparatus and method

    DOEpatents

    Baumgart, Chris W.; Ciarcia, Christopher A.

    2000-01-01

    An automatic target recognition apparatus (10) is provided, having a video camera/digitizer (12) for producing a digitized image signal (20) representing an image containing therein objects which objects are to be recognized if they meet predefined criteria. The digitized image signal (20) is processed within a video analysis subroutine (22) residing in a computer (14) in a plurality of parallel analysis chains such that the objects are presumed to be lighter in shading than the background in the image in three of the chains and further such that the objects are presumed to be darker than the background in the other three chains. In two of the chains the objects are defined by surface texture analysis using texture filter operations. In another two of the chains the objects are defined by background subtraction operations. In yet another two of the chains the objects are defined by edge enhancement processes. In each of the analysis chains a calculation operation independently determines an error factor relating to the probability that the objects are of the type which should be recognized, and a probability calculation operation combines the results of the analysis chains.

  4. Designing Learning Object Repositories as Systems for Managing Educational Communities Knowledge

    ERIC Educational Resources Information Center

    Sampson, Demetrios G.; Zervas, Panagiotis

    2013-01-01

    Over the past years, a number of international initiatives that recognize the importance of sharing and reusing digital educational resources among educational communities through the use of Learning Object Repositories (LORs) have emerged. Typically, these initiatives focus on collecting digital educational resources that are offered by their…

  5. Hierarchical object-based classification of ultra-high-resolution digital mapping camera (DMC) imagery for rangeland mapping and assessment

    USDA-ARS?s Scientific Manuscript database

    Ultra high resolution digital aerial photography has great potential to complement or replace ground measurements of vegetation cover for rangeland monitoring and assessment. We investigated object-based image analysis (OBIA) techniques for classifying vegetation in southwestern U.S. arid rangelands...

  6. Zolpidem 10 mg given at daytime is not antagonized by 300 mg caffeine in man.

    PubMed

    Mattila, M J; Nurminen, M L; Vainio, P; Vanakoski, J

    1998-07-01

    Caffeine counteracts various effects of traditional benzodiazepines (BZDs). As zolpidem, a short-acting hypnotic, is an atypical GABAA-BZD agonist, we investigated when caffeine would counteract the effects of zolpidem as well. In daytime study I, zolpidem 10 mg (capsule) and caffeine 150 or 300 mg (in decaffeinated coffee) were given, alone and in combinations, to parallel groups (n = 15-17) of healthy students in double-blind and placebo-controlled manner. Objective and subjective tests were done before and 45 min and 90 min after intake. Ranked delta values (changes from baseline) were analysed by one-way contrast ANOVA and Scheffe's tests. In daytime study II, four healthy subjects took zolpidem 10 mg alone, and together with blinded caffeine 250 mg or (at -45 min) erythromycin 750 mg. Objective and subjective effects were measured and plasma zolpidem concentrations assayed at baseline and 45 min and 90 min after zolpidem intake. In study I, practice effects after placebo (ad + 30%) were seen for letter cancellation and digit symbol substitution but not for flicker fusion tests. Zolpidem alone significantly impaired (P < 0.05 vs delta placebo) letter cancellation and digit symbol substitution at 45 min and 90 min, lowered the flicker fusion threshold at 45 min, and caused subjective drowsiness, mental slowness, clumsiness and feeling of poor performance. Caffeine alone showed a non-significant trend to improve objective performance. The combined effects of zolpidem and either dose of caffeine matched those measured after zolpidem alone. Zolpidem + caffeine 300 mg was not stronger than zolpidem + caffeine 150 mg in impairing immediate memory and causing subjective sedation. In study II, zolpidem caused objective and subjective sedation; neither caffeine nor erythromycin modulated the effects of zolpidem or plasma zolpidem concentrations. The sedative effects of 10 mg of zolpidem are not antagonized by 150-300 mg of caffeine in pharmacodynamic or pharmacokinetic terms.

  7. Accuracy and consistency of weights provided by home bathroom scales.

    PubMed

    Yorkin, Meredith; Spaccarotella, Kim; Martin-Biggers, Jennifer; Quick, Virginia; Byrd-Bredbenner, Carol

    2013-12-17

    Self-reported body weight is often used for calculation of Body Mass Index because it is easy to collect. Little is known about sources of error introduced by using bathroom scales to measure weight at home. The objective of this study was to evaluate the accuracy and consistency of digital versus dial-type bathroom scales commonly used for self-reported weight. Participants brought functioning bathroom scales (n=18 dial-type, n=43 digital-type) to a central location. Trained researchers assessed accuracy and consistency using certified calibration weights at 10 kg, 25 kg, 50 kg, 75 kg, 100 kg, and 110 kg. Data also were collected on frequency of calibration, age and floor surface beneath the scale. All participants reported using their scale on hard surface flooring. Before calibration, all digital scales displayed 0, but dial scales displayed a mean absolute initial weight of 0.95 (1.9 SD) kg. Digital scales accurately weighed test loads whereas dial-type scale weights differed significantly (p<0.05). Imprecision of dial scales was significantly greater than that of digital scales at all weights (p<0.05). Accuracy and precision did not vary by scale age. Digital home bathroom scales provide sufficiently accurate and consistent weights for public health research. Reminders to zero scales before each use may further improve accuracy of self-reported weight.

  8. Phase conjugate digital inline holography (PCDIH)

    DOE PAGES

    Guildenbecher, Daniel Robert; Hoffmeister, Kathryn N. Gabet; Kunzler, William Marley; ...

    2018-01-12

    We report digital inline holography (DIH) provides instantaneous three-dimensional (3D) measurements of diffracting objects; however, phase disturbances in the beam path can distort the imaging. In this Letter, a phase conjugate digital inline holography (PCDIH) configuration is proposed for removal of phase disturbances. Brillouin-enhanced four-wave mixing produces a phase conjugate signal that back propagates along the DIH beam path. Finally, the results demonstrate the removal of distortions caused by gas-phase shocks to recover 3D images of diffracting objects.

  9. Trends in the Evolution of the Public Web, 1998-2002; The Fedora Project: An Open-source Digital Object Repository Management System; State of the Dublin Core Metadata Initiative, April 2003; Preservation Metadata; How Many People Search the ERIC Database Each Day?

    ERIC Educational Resources Information Center

    O'Neill, Edward T.; Lavoie, Brian F.; Bennett, Rick; Staples, Thornton; Wayland, Ross; Payette, Sandra; Dekkers, Makx; Weibel, Stuart; Searle, Sam; Thompson, Dave; Rudner, Lawrence M.

    2003-01-01

    Includes five articles that examine key trends in the development of the public Web: size and growth, internationalization, and metadata usage; Flexible Extensible Digital Object and Repository Architecture (Fedora) for use in digital libraries; developments in the Dublin Core Metadata Initiative (DCMI); the National Library of New Zealand Te Puna…

  10. Phase conjugate digital inline holography (PCDIH)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Guildenbecher, Daniel Robert; Hoffmeister, Kathryn N. Gabet; Kunzler, William Marley

    We report digital inline holography (DIH) provides instantaneous three-dimensional (3D) measurements of diffracting objects; however, phase disturbances in the beam path can distort the imaging. In this Letter, a phase conjugate digital inline holography (PCDIH) configuration is proposed for removal of phase disturbances. Brillouin-enhanced four-wave mixing produces a phase conjugate signal that back propagates along the DIH beam path. Finally, the results demonstrate the removal of distortions caused by gas-phase shocks to recover 3D images of diffracting objects.

  11. Registration of 3D and Multispectral Data for the Study of Cultural Heritage Surfaces

    PubMed Central

    Chane, Camille Simon; Schütze, Rainer; Boochs, Frank; Marzani, Franck S.

    2013-01-01

    We present a technique for the multi-sensor registration of featureless datasets based on the photogrammetric tracking of the acquisition systems in use. This method is developed for the in situ study of cultural heritage objects and is tested by digitizing a small canvas successively with a 3D digitization system and a multispectral camera while simultaneously tracking the acquisition systems with four cameras and using a cubic target frame with a side length of 500 mm. The achieved tracking accuracy is better than 0.03 mm spatially and 0.150 mrad angularly. This allows us to seamlessly register the 3D acquisitions and to project the multispectral acquisitions on the 3D model. PMID:23322103

  12. The future of the application of the Bi-Digital O-Ring Test in Sports Psychology.

    PubMed

    Ozerkan, Kemal Nuri

    2005-01-01

    The Bi-Digital O-Ring Test, originally developed by Dr. Omura, utilizes changes in the degree of strength of voluntary movements of muscles of the fingers under a definite muscle tonus, making Bi-Digital O-Rings, as an indicator of pathology in the body. Research in Sports Psychology can use the classical measurement methods and Bi-Digital O-Ring Test method comparatively and thus produce new findings regarding the reliability and certainty of the Bi-Digital O-Ring Test test. It seems probable that by using the non-invasive Bi-Digital O-Ring Test test, it is possible to measure enzymes, hormones and neuro-transmitters instantaneously and assess a sports person's actual psychological and physiological performance, and thereby help them reach their peak performance levels during both exercise and competitions.

  13. Digital technologies in occupational therapy and physiotherapy undergraduate and postgraduate education: a scoping review protocol.

    PubMed

    Olivier, Benita; Verdonck, Michele; Casteleijn, Daleen

    2017-11-01

    How have digital technologies been used in occupational therapy and physiotherapy undergraduate and postgraduate education?Specifically, the objective of this scoping review is to present an overview of research on the use of digital technologies in terms of type of digital technology used, pedagogy associated with the use of digital technology, subject/topic/area of application, experiences/perception of digital technology used, outcomes of the digital technology used and challenges to the use of digital technologies in occupational therapy and physiotherapy undergraduate and postgraduate education.

  14. E-inclusion Process and Societal Digital Skill Development

    ERIC Educational Resources Information Center

    Vitolina, Ieva

    2015-01-01

    Nowadays, the focus shifts from information and communication technology access to skills and knowledge. Moreover, lack of digital skills is an obstacle in the process of learning new digital competences using technologies and e-learning. The objective of this research is to investigate how to facilitate students to use the acquired digital skills…

  15. Digital Image Analysis System for Monitoring Crack Growth at Elevated Temperature

    DTIC Science & Technology

    1988-05-01

    The objective of the research work reported here was to develop a new concept, based on Digital Image Analysis , for monitoring the crack-tip position...a 512 x 512 pixel frame. c) Digital Image Analysis software developed to locate and digitize the position of the crack-tip, on the observed image

  16. Border and surface tracing--theoretical foundations.

    PubMed

    Brimkov, Valentin E; Klette, Reinhard

    2008-04-01

    In this paper we define and study digital manifolds of arbitrary dimension, and provide (in particular)a general theoretical basis for curve or surface tracing in picture analysis. The studies involve properties such as one-dimensionality of digital curves and (n-1)-dimensionality of digital hypersurfaces that makes them discrete analogs of corresponding notions in continuous topology. The presented approach is fully based on the concept of adjacency relation and complements the concept of dimension as common in combinatorial topology. This work appears to be the first one on digital manifolds based ona graph-theoretical definition of dimension. In particular, in the n-dimensional digital space, a digital curve is a one-dimensional object and a digital hypersurface is an (n-1)-dimensional object, as it is in the case of curves and hypersurfaces in the Euclidean space. Relying on the obtained properties of digital hypersurfaces, we propose a uniform approach for studying good pairs defined by separations and obtain a classification of good pairs in arbitrary dimension. We also discuss possible applications of the presented definitions and results.

  17. Digitisation of Scenic and Historic Interest Areas in China

    NASA Astrophysics Data System (ADS)

    Yang, C.; Lawson, G.; Sim, J.

    2015-08-01

    Digital documents have become the major information source for heritage conservation practice. More heritage managers today use electronic maps and digital information systems to facilitate management and conservation of cultural heritage. However, the social aspects of digital heritage have not been sufficiently recognised. The aim of this paper is to examine China's `Digital Scenic Area' project, a national program started in 2004, to reveal the political and economic powers behind digital heritage practice. It was found that this project was only conducted within the most popular tourist destinations in China. Tourism information was the main object but information about landscape cultures were neglected in this project. This project also demonstrated that digital management was more like a political or economic symbol rather than a tool for heritage conservation. However, using digital technologies are still considered by the local government as a highly objective way of heritage management. Selected as a typical Scenic Area in China, Slender West Lake in Yangzhou was investigated to identify heritage stakeholder's attitudes toward digital management and the request from local management practice.

  18. Optical encryption of multiple three-dimensional objects based on multiple interferences and single-pixel digital holography

    NASA Astrophysics Data System (ADS)

    Wang, Ying; Liu, Qi; Wang, Jun; Wang, Qiong-Hua

    2018-03-01

    We present an optical encryption method of multiple three-dimensional objects based on multiple interferences and single-pixel digital holography. By modifying the Mach–Zehnder interferometer, the interference of the multiple objects beams and the one reference beam is used to simultaneously encrypt multiple objects into a ciphertext. During decryption, each three-dimensional object can be decrypted independently without having to decrypt other objects. Since the single-pixel digital holography based on compressive sensing theory is introduced, the encrypted data of this method is effectively reduced. In addition, recording fewer encrypted data can greatly reduce the bandwidth of network transmission. Moreover, the compressive sensing essentially serves as a secret key that makes an intruder attack invalid, which means that the system is more secure than the conventional encryption method. Simulation results demonstrate the feasibility of the proposed method and show that the system has good security performance. Project supported by the National Natural Science Foundation of China (Grant Nos. 61405130 and 61320106015).

  19. Comparison of linear measurements and analyses taken from plaster models and three-dimensional images.

    PubMed

    Porto, Betina Grehs; Porto, Thiago Soares; Silva, Monica Barros; Grehs, Renésio Armindo; Pinto, Ary dos Santos; Bhandi, Shilpa H; Tonetto, Mateus Rodrigues; Bandéca, Matheus Coelho; dos Santos-Pinto, Lourdes Aparecida Martins

    2014-11-01

    Digital models are an alternative for carrying out analyses and devising treatment plans in orthodontics. The objective of this study was to evaluate the accuracy and the reproducibility of measurements of tooth sizes, interdental distances and analyses of occlusion using plaster models and their digital images. Thirty pairs of plaster models were chosen at random, and the digital images of each plaster model were obtained using a laser scanner (3Shape R-700, 3Shape A/S). With the plaster models, the measurements were taken using a caliper (Mitutoyo Digimatic(®), Mitutoyo (UK) Ltd) and the MicroScribe (MS) 3DX (Immersion, San Jose, Calif). For the digital images, the measurement tools used were those from the O3d software (Widialabs, Brazil). The data obtained were compared statistically using the Dahlberg formula, analysis of variance and the Tukey test (p < 0.05). The majority of the measurements, obtained using the caliper and O3d were identical, and both were significantly different from those obtained using the MS. Intra-examiner agreement was lowest when using the MS. The results demonstrated that the accuracy and reproducibility of the tooth measurements and analyses from the plaster models using the caliper and from the digital models using O3d software were identical.

  20. An enhanced digital line graph design

    USGS Publications Warehouse

    Guptill, Stephen C.

    1990-01-01

    In response to increasing information demands on its digital cartographic data, the U.S. Geological Survey has designed an enhanced version of the Digital Line Graph, termed Digital Line Graph - Enhanced (DLG-E). In the DLG-E model, the phenomena represented by geographic and cartographic data are termed entities. Entities represent individual phenomena in the real world. A feature is an abstraction of a set of entities, with the feature description encompassing only selected properties of the entities (typically the properties that have been portrayed cartographically on a map). Buildings, bridges, roads, streams, grasslands, and counties are examples of features. A feature instance, that is, one occurrence of a feature, is described in the digital environment by feature objects and spatial objects. A feature object identifies a feature instance and its nonlocational attributes. Nontopological relationships are associated with feature objects. The locational aspects of the feature instance are represented by spatial objects. Four spatial objects (points, nodes, chains, and polygons) and their topological relationships are defined. To link the locational and nonlocational aspects of the feature instance, a given feature object is associated with (or is composed of) a set of spatial objects. These objects, attributes, and relationships are the components of the DLG-E data model. To establish a domain of features for DLG-E, an approach using a set of classes, or views, of spatial entities was adopted. The five views that were developed are cover, division, ecosystem, geoposition, and morphology. The views are exclusive; each view is a self-contained analytical approach to the entire range of world features. Because each view is independent of the others, a single point on the surface of the Earth can be represented under multiple views. Under the five views, over 200 features were identified and defined. This set constitutes an initial domain of DLG-E features.

  1. A Call to Digital Health Practitioners: New Guidelines Can Help Improve the Quality of Digital Health Evidence

    PubMed Central

    Agarwal, Smisha; Lefevre, Amnesty E

    2017-01-01

    Background Despite the rapid proliferation of health interventions that employ digital tools, the evidence on the effectiveness of such approaches remains insufficient and of variable quality. To address gaps in the comprehensiveness and quality of reporting on the effectiveness of digital programs, the mHealth Technical Evidence Review Group (mTERG), convened by the World Health Organization, proposed the mHealth Evidence Reporting and Assessment (mERA) checklist to address existing gaps in the comprehensiveness and quality of reporting on the effectiveness of digital health programs. Objective We present an overview of the mERA checklist and encourage researchers working in the digital health space to use the mERA checklist for reporting their research. Methods The development of the mERA checklist consisted of convening an expert group to recommend an appropriate approach, convening a global expert review panel for checklist development, and pilot-testing the checklist. Results The mERA checklist consists of 16 core mHealth items that define what the mHealth intervention is (content), where it is being implemented (context), and how it was implemented (technical features). Additionally, a 29-item methodology checklist guides authors on reporting critical aspects of the research methodology employed in the study. We recommend that the core mERA checklist is used in conjunction with an appropriate study-design specific checklist. Conclusions The mERA checklist aims to assist authors in reporting on digital health research, guide reviewers and policymakers in synthesizing evidence, and guide journal editors in assessing the completeness in reporting on digital health studies. An increase in transparent and rigorous reporting can help identify gaps in the conduct of research and understand the effects of digital health interventions as a field of inquiry. PMID:28986340

  2. Modified-Symbol Digit Modalities Test for African Americans, Caribbean Black Americans and Non-Latino Whites: Nationally Representative Normative Data from the National Survey of American Life

    PubMed Central

    González, Hector M.; Whitfield, Keith E.; West, Brady T.; Williams, David R.; Lichtenberg, Peter; Jackson, James S.

    2007-01-01

    Normative neuropsychological data for U.S. racial/ethnic minorities is limited. Extant norms are based on small, regional groups that may not be nationally representative. The objectives of this study were to 1) provide norms for a modified Symbol Digit Modalities Test (M-SDMT) based on a nationally representative sample of African Americans, Caribbean Blacks and non-Latino Whites (NLW) living in areas with large populations of Blacks, and 2) determine significant correlates of M-SDMT performance. The M-SDMT was administered to a subset of respondents from the National Survey of American Life in standard, face-to-face interviews. M-SDMT performance was influenced by race/ethnicity, age, education, and gender. African Americans and NLW groups had similar M-SDMT performances, which differed from Caribbean Blacks. The Black ethnic differences in M-SDMT were not explained by the sociodemographic factors considered in this study. Unlike previous work, this study supports the consideration of Black ethnicity when evaluating Black neuropsychological test performance. PMID:17493782

  3. Digital Image Correlation for Performance Monitoring

    NASA Technical Reports Server (NTRS)

    Palaviccini, Miguel; Turner, Dan; Herzberg, Michael

    2016-01-01

    Evaluating the health of a mechanism requires more than just a binary evaluation of whether an operation was completed. It requires analyzing more comprehensive, full-field data. Health monitoring is a process of non-destructively identifying characteristics that indicate the fitness of an engineered component. In order to monitor unit health in a production setting, an automated test system must be created to capture the motion of mechanism parts in a real-time and non-intrusive manner. One way to accomplish this is by using high-speed video and Digital Image Correlation (DIC). In this approach, individual frames of the video are analyzed to track the motion of mechanism components. The derived performance metrics allow for state-of-health monitoring and improved fidelity of mechanism modeling. The results are in-situ state-of-health identification and performance prediction. This paper introduces basic concepts of this test method, and discusses two main themes: the use of laser marking to add fiducial patterns to mechanism components, and new software developed to track objects with complex shapes, even as they move behind obstructions. Finally, the implementation of these tests into an automated tester is discussed.

  4. Testing--1,2,...523,...641,...999--Testing: The MDT Multi-Digit Technique Applied to Science Education.

    ERIC Educational Resources Information Center

    Anderson, Paul S.; Schoner, James S.

    The MDT multi-digit technique, a development in testing technology, is described; and its application to science classrooms is discussed. Some actual materials for use in a cell biology class are included. The primary characteristic of an MDT multi-digit test is a long list of possible responses, with each term marked with a three-digit number…

  5. Acute comparison of clovoxamine and mianserin, alone and in combination with ethanol, on human psychomotor performance.

    PubMed

    Strömberg, C; Mattila, M J

    1987-05-01

    Objective and subjective effects on human performance of clovoxamine and mianserin were measured in 12 student volunteers who participated in 12 test sessions and received single doses of clovoxamine 50 mg, 100 mg and 150 mg, mianserin 20 mg, and placebo in a double-blind and cross-over manner. Each test drug was given twice, both in combination with alcohol 0.8 g/kg and with a non-alcoholic drink. The tests included tracking, body balance, flicker fusion, horizontal nystagmus, digit symbol substitution, recall memory, and subjective assessments on visual analogue scales. Mianserin and alcohol impaired objective performance in most tests, and their combination showed at least an additive effect. Alcohol counteracted rather than increased mianserin-induced subjective sedation. Clovoxamine neither differed significantly from placebo nor increased alcohol effects. On the contrary, clovoxamine 150 mg reduced significantly alcohol-induced body sway. No evidence of pharmacokinetic interactions were found between the study drugs and alcohol.

  6. Involving a young person in the development of a digital resource in nurse education.

    PubMed

    Fenton, Gaynor

    2014-01-01

    Health policies across western societies have embedded the need for service user and carer perspectives in service design and delivery of educational programmes. There is a growing recognition of the need to include the perspectives of children and young people as service users in the design and delivery of child focused educational programmes. Digital storytelling provides a strategy for student nurses to gain insight into the lived experiences of children and young people. Engaging with these stories enables students to develop an understanding of a young persons' experience of healthcare. This paper outlines a project that developed a digital learning object based upon a young person's experience of cancer and student evaluations of the digital learning object as a teaching and learning strategy. Over 80% of students rated the digital learning object as interesting and were motivated to explore its content. In addition, the evaluation highlighted that listening to the young person's experiences of her treatment regimes was informative and assisted understanding of a patients' perspective of care delivery. Copyright © 2013 Elsevier Ltd. All rights reserved.

  7. Experimental research of digital holographic microscopic measuring

    NASA Astrophysics Data System (ADS)

    Zhu, Xueliang; Chen, Feifei; Li, Jicheng

    2013-06-01

    Digital holography is a new imaging technique, which is developed on the base of optical holography, Digital processing, and Computer techniques. It is using CCD instead of the conventional silver to record hologram, and then reproducing the 3D contour of the object by the way of computer simulation. Compared with the traditional optical holographic, the whole process is of simple measuring, lower production cost, faster the imaging speed, and with the advantages of non-contact real-time measurement. At present, it can be used in the fields of the morphology detection of tiny objects, micro deformation analysis, and biological cells shape measurement. It is one of the research hot spot at home and abroad. This paper introduced the basic principles and relevant theories about the optical holography and Digital holography, and researched the basic questions which influence the reproduce images in the process of recording and reconstructing of the digital holographic microcopy. In order to get a clear digital hologram, by analyzing the optical system structure, we discussed the recording distance and of the hologram. On the base of the theoretical studies, we established a measurement and analyzed the experimental conditions, then adjusted them to the system. To achieve a precise measurement of tiny object in three-dimension, we measured MEMS micro device for example, and obtained the reproduction three-dimensional contour, realized the three dimensional profile measurement of tiny object. According to the experiment results consider: analysis the reference factors between the zero-order term and a pair of twin-images by the choice of the object light and the reference light and the distance of the recording and reconstructing and the characteristics of reconstruction light on the measurement, the measurement errors were analyzed. The research result shows that the device owns certain reliability.

  8. Association between digital dermatoglyphics and handedness among Sinhalese in Sri Lanka

    PubMed Central

    Wijerathne, Buddhika TB; Rathnayake, Geetha K

    2013-01-01

    Background The relationship between handedness and digital dermatoglyphic patterns has never been investigated in the Sinhalese population. The goal of this study is to establish the above mentioned relationship, which would positively aid personal identification.  Findings One hundred forty Sinhalese students (70 right-handed and 70 left-handed) were studied for their digital dermatoglyphic pattern distribution. The results show that a statistically significant correlation exists for; digit 5 (Ulnar loop; P= 0.0449 and radial loop; P= 0.0248 by Fisher’s exact test) of the right hand in female, digit 1 (radial loop; P=0.0248 by Fisher’s exact test) and digit 2 (Ulnar loop; P=0.0306) of the left hand in females, digit 3 (Ulnar loop; P= 0.0486 and whorl; P= 0.0356 by Fisher’s exact test) and digit 4 (Ulnar loop; P= 0.0449 and whorl; P= 0.0301 by Fisher’s exact test) of the right hand in males, digit 4 (whorl; P=0.0160 by Fisher’s exact test) of the left hand in males. Conclusions  Statistically significant differences in handedness and digital dermatoglyphic patterns were evident among Sinhalese people. Further study with a larger sample size is recommended. PMID:24627780

  9. Sensorimotor memory of object weight distribution during multidigit grasp.

    PubMed

    Albert, Frederic; Santello, Marco; Gordon, Andrew M

    2009-10-09

    We studied the ability to transfer three-digit force sharing patterns learned through consecutive lifts of an object with an asymmetric center of mass (CM). After several object lifts, we asked subjects to rotate and translate the object to the contralateral hand and perform one additional lift. This task was performed under two weight conditions (550 and 950 g) to determine the extent to which subjects would be able to transfer weight and CM information. Learning transfer was quantified by measuring the extent to which force sharing patterns and peak object roll on the first post-translation trial resembled those measured on the pre-translation trial with the same CM. We found that the overall gain of fingertip forces was transferred following object rotation, but that the scaling of individual digit forces was specific to the learned digit-object configuration, and thus was not transferred following rotation. As a result, on the first post-translation trial there was a significantly larger object roll following object lift-off than on the pre-translation trial. This suggests that sensorimotor memories for weight, requiring scaling of fingertip force gain, may differ from memories for mass distribution.

  10. Herschel Observations of Protostellar and Young Stellar Objects in Nearby Molecular Clouds: The DIGIT Open Time Key Project

    NASA Astrophysics Data System (ADS)

    Green, Joel D.; DIGIT OTKP Team

    2010-01-01

    The DIGIT (Dust, Ice, and Gas In Time) Open Time Key Project utilizes the PACS spectrometer (57-210 um) onboard the Herschel Space Observatory to study the colder regions of young stellar objects and protostellar cores, complementary to recent observations from Spitzer and ground-based observatories. DIGIT focuses on 30 embedded sources and 64 disk sources, and includes supporting photometry from PACS and SPIRE, as well as spectroscopy from HIFI, selected from nearby molecular clouds. For the embedded sources, PACS spectroscopy will allow us to address the origin of [CI] and high-J CO lines observed with ISO-LWS. Our observations are sensitive to the presence of cold crystalline water ice, diopside, and carbonates. Additionally, PACS scans are 5x5 maps of the embedded sources and their outflows. Observations of more evolved disk sources will sample low and intermediate mass objects as well as a variety of spectral types from A to M. Many of these sources are extremely rich in mid-IR crystalline dust features, enabling us to test whether similar features can be detected at larger radii, via colder dust emission at longer wavelengths. If processed grains are present only in the inner disk (in the case of full disks) or from the emitting wall surface which marks the outer edge of the gap (in the case of transitional disks), there must be short timescales for dust processing; if processed grains are detected in the outer disk, radial transport must be rapid and efficient. Weak bands of forsterite and clino- and ortho-enstatite in the 60-75 um range provide information about the conditions under which these materials were formed. For the Science Demonstration Phase we are observing an embedded protostar (DK Cha) and a Herbig Ae/Be star (HD 100546), exemplars of the kind of science that DIGIT will achieve over the full program.

  11. Digital Rights Management Implemented by RDF Graph Approach

    ERIC Educational Resources Information Center

    Yang, Jin Tan; Horng, Huai-Chien

    2006-01-01

    This paper proposes a design framework for constructing Digital Rights Management (DRM) that enables learning objects in legal usage. The central theme of this framework is that any design of a DRM must have theories as foundations to make the maintenance, extension or interoperability easy. While a learning objective consists of learning…

  12. Quality Assurance for Digital Learning Object Repositories: Issues for the Metadata Creation Process

    ERIC Educational Resources Information Center

    Currier, Sarah; Barton, Jane; O'Beirne, Ronan; Ryan, Ben

    2004-01-01

    Metadata enables users to find the resources they require, therefore it is an important component of any digital learning object repository. Much work has already been done within the learning technology community to assure metadata quality, focused on the development of metadata standards, specifications and vocabularies and their implementation…

  13. Problem-Solving Examples as Interactive Learning Objects for Educational Digital Libraries

    ERIC Educational Resources Information Center

    Brusilovsky, Peter; Yudelson, Michael; Hsiao, I-Han

    2009-01-01

    The paper analyzes three major problems encountered by our team as we endeavored to turn problem solving examples in the domain of programming into highly reusable educational activities, which could be included as first class objects in various educational digital libraries. It also suggests three specific approaches to resolving these problems,…

  14. iLOG: A Framework for Automatic Annotation of Learning Objects with Empirical Usage Metadata

    ERIC Educational Resources Information Center

    Miller, L. D.; Soh, Leen-Kiat; Samal, Ashok; Nugent, Gwen

    2012-01-01

    Learning objects (LOs) are digital or non-digital entities used for learning, education or training commonly stored in repositories searchable by their associated metadata. Unfortunately, based on the current standards, such metadata is often missing or incorrectly entered making search difficult or impossible. In this paper, we investigate…

  15. Comparative analysis of autofocus functions in digital in-line phase-shifting holography.

    PubMed

    Fonseca, Elsa S R; Fiadeiro, Paulo T; Pereira, Manuela; Pinheiro, António

    2016-09-20

    Numerical reconstruction of digital holograms relies on a precise knowledge of the original object position. However, there are a number of relevant applications where this parameter is not known in advance and an efficient autofocusing method is required. This paper addresses the problem of finding optimal focusing methods for use in reconstruction of digital holograms of macroscopic amplitude and phase objects, using digital in-line phase-shifting holography in transmission mode. Fifteen autofocus measures, including spatial-, spectral-, and sparsity-based methods, were evaluated for both synthetic and experimental holograms. The Fresnel transform and the angular spectrum reconstruction methods were compared. Evaluation criteria included unimodality, accuracy, resolution, and computational cost. Autofocusing under angular spectrum propagation tends to perform better with respect to accuracy and unimodality criteria. Phase objects are, generally, more difficult to focus than amplitude objects. The normalized variance, the standard correlation, and the Tenenbaum gradient are the most reliable spatial-based metrics, combining computational efficiency with good accuracy and resolution. A good trade-off between focus performance and computational cost was found for the Fresnelet sparsity method.

  16. Low cost 3D scanning process using digital image processing

    NASA Astrophysics Data System (ADS)

    Aguilar, David; Romero, Carlos; Martínez, Fernando

    2017-02-01

    This paper shows the design and building of a low cost 3D scanner, able to digitize solid objects through contactless data acquisition, using active object reflection. 3D scanners are used in different applications such as: science, engineering, entertainment, etc; these are classified in: contact scanners and contactless ones, where the last ones are often the most used but they are expensive. This low-cost prototype is done through a vertical scanning of the object using a fixed camera and a mobile horizontal laser light, which is deformed depending on the 3-dimensional surface of the solid. Using digital image processing an analysis of the deformation detected by the camera was done; it allows determining the 3D coordinates using triangulation. The obtained information is processed by a Matlab script, which gives to the user a point cloud corresponding to each horizontal scanning done. The obtained results show an acceptable quality and significant details of digitalized objects, making this prototype (built on LEGO Mindstorms NXT kit) a versatile and cheap tool, which can be used for many applications, mainly by engineering students.

  17. s48-e-007

    NASA Image and Video Library

    2013-01-15

    S48-E-007 (12 Sept 1991) --- Astronaut James F. Buchli, mission specialist, catches snack crackers as they float in the weightless environment of the earth-orbiting Discovery. This image was transmitted by the Electronic Still Camera, Development Test Objective (DTO) 648. The ESC is making its initial appearance on a Space Shuttle flight. Electronic still photography is a new technology that enables a camera to electronically capture and digitize an image with resolution approaching film quality. The digital image is stored on removable hard disks or small optical disks, and can be converted to a format suitable for downlink transmission or enhanced using image processing software. The Electronic Still Camera (ESC) was developed by the Man- Systems Division at the Johnson Space Center and is the first model in a planned evolutionary development leading to a family of high-resolution digital imaging devices. H. Don Yeates, JSC's Man-Systems Division, is program manager for the ESC. THIS IS A SECOND GENERATION PRINT MADE FROM AN ELECTRONICALLY PRODUCED NEGATIVE

  18. Filmless radiology: The design, integration, implementation, and evaluation of a digital imaging network. Potential investigations to be conducted in conjunction with the Digital-Imaging Network System (DINS) evaluation project. Revision 1. Annual report, 1 March 1987-28 February 1988

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kerlin, B.D.; Cerva, J.R.; Glenn, M.E.

    This document describes evaluation studies and technical investigations proposed for the three-year Digital Imaging Network System (DINS) prototype project, sponsored by the U.S. Army Medical Research and Development Command, Ft. Detrick, Maryland. The project has three overall goals. The first is to install and operate a prototype DINS at each of two University-based hospitals for test purposes. The second is to evaluate key aspects of each prototype system once it is in full operation. The third is to develop guidelines and specifications for an operational DINS suitable for use by the military and others developing systems of the future. Thismore » document defines twelve overall evaluative questions for use in meeting the second and third objectives of the project and proposes studies that will answer these questions.« less

  19. Digital learning objects in nursing consultation: technology assessment by undergraduate students.

    PubMed

    Silveira, DeniseTolfo; Catalan, Vanessa Menezes; Neutzling, Agnes Ludwig; Martinato, Luísa Helena Machado

    2010-01-01

    This study followed the teaching-learning process about the nursing consultation, based on digital learning objects developed through the active Problem Based Learning method. The goals were to evaluate the digital learning objects about nursing consultation, develop cognitive skills on the subject using problem based learning and identify the students' opinions on the use of technology. This is an exploratory and descriptive study with a quantitative approach. The sample consisted of 71 students in the sixth period of the nursing program at the Federal University of Rio Grande do Sul. The data was collected through a questionnaire to evaluate the learning objects. The results showed positive agreement (58%) on the content, usability and didactics of the proposed computer-mediated activity regarding the nursing consultation. The application of materials to the students is considered positive.

  20. An objectively-analyzed method for measuring the useful penetration of x-ray imaging systems.

    PubMed

    Glover, Jack L; Hudson, Lawrence T

    2016-06-01

    The ability to detect wires is an important capability of the cabinet x-ray imaging systems that are used in aviation security as well as the portable x-ray systems that are used by domestic law enforcement and military bomb squads. A number of national and international standards describe methods for testing this capability using the so called useful penetration test metric, where wires are imaged behind different thicknesses of blocking material. Presently, these tests are scored based on human judgments of wire visibility, which are inherently subjective. We propose a new method in which the useful penetration capabilities of an x-ray system are objectively evaluated by an image processing algorithm operating on digital images of a standard test object. The algorithm advantageously applies the Radon transform for curve parameter detection that reduces the problem of wire detection from two dimensions to one. The sensitivity of the wire detection method is adjustable and we demonstrate how the threshold parameter can be set to give agreement with human-judged results. The method was developed to be used in technical performance standards and is currently under ballot for inclusion in a US national aviation security standard.

  1. An objectively-analyzed method for measuring the useful penetration of x-ray imaging systems

    PubMed Central

    Glover, Jack L.; Hudson, Lawrence T.

    2016-01-01

    The ability to detect wires is an important capability of the cabinet x-ray imaging systems that are used in aviation security as well as the portable x-ray systems that are used by domestic law enforcement and military bomb squads. A number of national and international standards describe methods for testing this capability using the so called useful penetration test metric, where wires are imaged behind different thicknesses of blocking material. Presently, these tests are scored based on human judgments of wire visibility, which are inherently subjective. We propose a new method in which the useful penetration capabilities of an x-ray system are objectively evaluated by an image processing algorithm operating on digital images of a standard test object. The algorithm advantageously applies the Radon transform for curve parameter detection that reduces the problem of wire detection from two dimensions to one. The sensitivity of the wire detection method is adjustable and we demonstrate how the threshold parameter can be set to give agreement with human-judged results. The method was developed to be used in technical performance standards and is currently under ballot for inclusion in a US national aviation security standard. PMID:27499586

  2. An objectively-analyzed method for measuring the useful penetration of x-ray imaging systems

    NASA Astrophysics Data System (ADS)

    Glover, Jack L.; Hudson, Lawrence T.

    2016-06-01

    The ability to detect wires is an important capability of the cabinet x-ray imaging systems that are used in aviation security as well as the portable x-ray systems that are used by domestic law enforcement and military bomb squads. A number of national and international standards describe methods for testing this capability using the so called useful penetration test metric, where wires are imaged behind different thicknesses of blocking material. Presently, these tests are scored based on human judgments of wire visibility, which are inherently subjective. We propose a new method in which the useful penetration capabilities of an x-ray system are objectively evaluated by an image processing algorithm operating on digital images of a standard test object. The algorithm advantageously applies the Radon transform for curve parameter detection that reduces the problem of wire detection from two dimensions to one. The sensitivity of the wire detection method is adjustable and we demonstrate how the threshold parameter can be set to give agreement with human-judged results. The method was developed to be used in technical performance standards and is currently under ballot for inclusion in an international aviation security standard.

  3. Three degree-of-freedom force feedback control for robotic mating of umbilical lines

    NASA Technical Reports Server (NTRS)

    Fullmer, R. Rees

    1988-01-01

    The use of robotic manipulators for the mating and demating of umbilical fuel lines to the Space Shuttle Vehicle prior to launch is investigated. Force feedback control is necessary to minimize the contact forces which develop during mating. The objective is to develop and demonstrate a working robotic force control system. Initial experimental force control tests with an ASEA IRB-90 industrial robot using the system's Adaptive Control capabilities indicated that control stability would by a primary problem. An investigation of the ASEA system showed a 0.280 second software delay between force input commands and the output of command voltages to the servo system. This computational delay was identified as the primary cause of the instability. Tests on a second path into the ASEA's control computer using the MicroVax II supervisory computer show that time delay would be comparable, offering no stability improvement. An alternative approach was developed where the digital control system of the robot was disconnected and an analog electronic force controller was used to control the robot's servosystem directly, allowing the robot to use force feedback control while in rigid contact with a moving three-degree-of-freedom target. An alternative approach was developed where the digital control system of the robot was disconnected and an analog electronic force controller was used to control the robot's servo system directly. This method allowed the robot to use force feedback control while in rigid contact with moving three degree-of-freedom target. Tests on this approach indicated adequate force feedback control even under worst case conditions. A strategy to digitally-controlled vision system was developed. This requires switching between the digital controller when using vision control and the analog controller when using force control, depending on whether or not the mating plates are in contact.

  4. Correlation of digital health use and chronic pain coping strategies.

    PubMed

    Ranney, Megan L; Duarte, Cassandra; Baird, Janette; Patry, Emily J; Green, Traci C

    2016-01-01

    Digital health is an increasingly popular tool for patient engagement, having shown great success in arenas such as medication adherence, management of chronic conditions, and patient safety. Given the growth of chronic pain diagnoses, it is imperative to find new technologies to improve care for this particular population. Little research has catalogued the use of digital health in the chronic pain patient population. This manuscript's objective was to describe current patterns of digital health usage among chronic pain patients and how digital health use correlates with health care utilization and health outcomes. A cross-sectional survey was administered to patients with a self-identified chronic pain diagnosis participating in 'Patients Like Me' ® (PLM), an organization that directly collects data from patients experiencing chronic health conditions, with emphasis on patient-centered outcomes and experiences interacting with the health care system. Validated measures of healthcare utilization, chronic pain management, and digital health use were adapted for the survey. Digital health was defined as the use of online sites, social media, and mobile phone applications before, during, or after healthcare utilization. Descriptive statistics, chi square tests, logistic regression, and linear regression were used as appropriate for analysis. Among 565 respondents (mean age 51.3, 87.2% female, 45.7% publicly insured), most participants (89.5%) reported some digital health use. Females and users below the age of 50 were more likely to use multiple forms of digital health. Healthcare utilization, education level, and race/ethnicity did not correlate with digital health use. Patients using more types of digital health reported significantly higher levels of pain coping skills in the realms of social support, relaxation, and exercise. Digital health use is common among a wide range of patients with chronic pain diagnoses. The use of multiple forms of digital health is associated with improved chronic pain coping mechanisms. Future work should explore the directional relationship between digital health tools and chronic pain coping skills, as well as which components of digital health have the most effect on chronic pain management and other patient-centered outcomes.

  5. Correlation of digital health use and chronic pain coping strategies

    PubMed Central

    Duarte, Cassandra; Baird, Janette; Patry, Emily J.; Green, Traci C.

    2016-01-01

    Background Digital health is an increasingly popular tool for patient engagement, having shown great success in arenas such as medication adherence, management of chronic conditions, and patient safety. Given the growth of chronic pain diagnoses, it is imperative to find new technologies to improve care for this particular population. Little research has catalogued the use of digital health in the chronic pain patient population. This manuscript’s objective was to describe current patterns of digital health usage among chronic pain patients and how digital health use correlates with health care utilization and health outcomes. Methods A cross-sectional survey was administered to patients with a self-identified chronic pain diagnosis participating in ‘Patients Like Me’® (PLM), an organization that directly collects data from patients experiencing chronic health conditions, with emphasis on patient-centered outcomes and experiences interacting with the health care system. Validated measures of healthcare utilization, chronic pain management, and digital health use were adapted for the survey. Digital health was defined as the use of online sites, social media, and mobile phone applications before, during, or after healthcare utilization. Descriptive statistics, chi square tests, logistic regression, and linear regression were used as appropriate for analysis. Results Among 565 respondents (mean age 51.3, 87.2% female, 45.7% publicly insured), most participants (89.5%) reported some digital health use. Females and users below the age of 50 were more likely to use multiple forms of digital health. Healthcare utilization, education level, and race/ethnicity did not correlate with digital health use. Patients using more types of digital health reported significantly higher levels of pain coping skills in the realms of social support, relaxation, and exercise. Conclusions Digital health use is common among a wide range of patients with chronic pain diagnoses. The use of multiple forms of digital health is associated with improved chronic pain coping mechanisms. Future work should explore the directional relationship between digital health tools and chronic pain coping skills, as well as which components of digital health have the most effect on chronic pain management and other patient-centered outcomes. PMID:28293608

  6. Primary Study of Attitudes of Schoolchildren in Rural and Remote Areas toward Digital Imaging Learning--Taking Film-Making Summer Camp as an Example

    ERIC Educational Resources Information Center

    Lee, Szu-Hsin

    2016-01-01

    No matter how fast or wide digital technology develops, because of the gap between urban and rural areas, a digital divide in the education system still exists. The researcher joined the digital film-making summer camp, where the major objective was to decrease the digital divide between urban and rural areas. Thirty schoolchildren from one…

  7. Evaluation of the color stability of two techniques for reproducing artificial irides after microwave polymerization

    PubMed Central

    GOIATO, Marcelo Coelho; dos SANTOS, Daniela Micheline; MORENO, Amália; GENNARI-FILHO, Humberto; PELLIZZER, Eduardo Piza

    2011-01-01

    The use of ocular prostheses for ophthalmic patients aims to rebuild facial aesthetics and provide an artificial substitute to the visual organ. Natural intemperate conditions promote discoloration of artificial irides and many studies have attempted to produce irides with greater chromatic paint durability using different paint materials. Objectives The present study evaluated the color stability of artificial irides obtained with two techniques (oil painting and digital image) and submitted to microwave polymerization. Material and Methods Forty samples were fabricated simulating ocular prostheses. Each sample was constituted by one disc of acrylic resin N1 and one disc of colorless acrylic resin with the iris interposed between the discs. The irides in brown and blue color were obtained by oil painting or digital image. The color stability was determined by a reflection spectrophotometer and measurements were taken before and after microwave polymerization. Statistical analysis of the techniques for reproducing artificial irides was performed by applying the normal data distribution test followed by 2-way ANOVA and Tukey HSD test (α=.05). Results Chromatic alterations occurred in all specimens and statistically significant differences were observed between the oil-painted samples and those obtained by digital imaging. There was no statistical difference between the brown and blue colors. Independently of technique, all samples suffered color alterations after microwave polymerization. Conclusion The digital imaging technique for reproducing irides presented better color stability after microwave polymerization. PMID:21625733

  8. Digital Histories for the Digital Age: Collaborative Writing in Large Lecture Courses

    ERIC Educational Resources Information Center

    Soh, Leen-Kiat; Khandaker, Nobel; Thomas, William G.

    2013-01-01

    The digital environment has had an immense effect on American society, learning, and education: we have more sources available at our fingertips than any previous generation. Teaching and learning with these new sources, however, has been a challenging transition. Students are confronted with an ocean of digital objects and need skills to navigate…

  9. Remote interferometry by digital holography for shape control

    NASA Astrophysics Data System (ADS)

    Baumbach, Torsten; Osten, Wolfgang; Falldorf, Claas; Jueptner, Werner P. O.

    2002-06-01

    Modern production requires more and more effective methods for the inspection and quality control at the production place. Outsourcing and globalization result in possible large distances between co-operating partners. This may cause serious problems with respect to the just-in-time exchange of information and the response to possible violations of quality standards. Consequently new challenges arise for optical measurement techniques especially in the field of industrial shape control. A possible solution for these problems can be delivered by a technique that stores optically the full 3D information of the objects to be compared and where the data can be transported over large distances. In this paper we describe the progress in implementing a new technique for the direct comparison of the shape and deformation of two objects with different microstructure where it is not necessary that both samples are located at the same place. This is done by creating a coherent mask for the illumination of the sample object. The coherent mask is created by Digital Holography to enable the instant access to the complete optical information of the master object at any wanted place. The transmission of the digital master holograms to this place can be done via digital telecommunication networks. The comparison can be done in a digital or analogue way. Both methods result in a disappearance of the object shape and the appearance of the shape or deformation difference between the two objects only. The analogue reconstruction of the holograms with a liquid crystal spatial light modulator can be done by using the light modulator as an intensity modulator or as an phase modulator. The reconstruction technique and the space bandwidth of the light modulator will influence the quality of the result. Therefore the paper describes the progress in applying modern spatial light modulators and digital cameras for the effective storage and optical reconstruction of coherent masks.

  10. Setup calibration and optimization for comparative digital holography

    NASA Astrophysics Data System (ADS)

    Baumbach, Torsten; Osten, Wolfgang; Kebbel, Volker; von Kopylow, Christoph; Jueptner, Werner

    2004-08-01

    With increasing globalization many enterprises decide to produce the components of their products at different locations all over the world. Consequently, new technologies and strategies for quality control are required. In this context the remote comparison of objects with regard to their shape or response on certain loads is getting more and more important for a variety of applications. For such a task the novel method of comparative digital holography is a suitable tool with interferometric sensitivity. With this technique the comparison in shape or deformation of two objects does not require the presence of both objects at the same place. In contrast to the well known incoherent techniques based on inverse fringe projection this new approach uses a coherent mask for the illumination of the sample object. The coherent mask is created by digital holography to enable the instant access to the complete optical information of the master object at any wanted place. The reconstruction of the mask is done by a spatial light modulator (SLM). The transmission of the digital master hologram to the place of comparison can be done via digital telecommunication networks. Contrary to other interferometric techniques this method enables the comparison of objects with different microstructure. In continuation of earlier reports our investigations are focused here on the analysis of the constraints of the setup with respect to the quality of the hologram reconstruction with a spatial light modulator. For successful measurements the selection of the appropriate reconstruction method and the adequate optical set-up is mandatory. In addition, the use of a SLM for the reconstruction requires the knowledge of its properties for the accomplishment of this method. The investigation results for the display properties such as display curvature, phase shift and the consequences for the technique will be presented. The optimization and the calibration of the set-up and its components lead to improved results in comparative digital holography with respect to the resolution. Examples of measurements before and after the optimization and calibration will be presented.

  11. Practical system for generating digital mixed reality video holograms.

    PubMed

    Song, Joongseok; Kim, Changseob; Park, Hanhoon; Park, Jong-Il

    2016-07-10

    We propose a practical system that can effectively mix the depth data of real and virtual objects by using a Z buffer and can quickly generate digital mixed reality video holograms by using multiple graphic processing units (GPUs). In an experiment, we verify that real objects and virtual objects can be merged naturally in free viewing angles, and the occlusion problem is well handled. Furthermore, we demonstrate that the proposed system can generate mixed reality video holograms at 7.6 frames per second. Finally, the system performance is objectively verified by users' subjective evaluations.

  12. Testbed for Satellite and Terrestrial Interoperability (TSTI)

    NASA Technical Reports Server (NTRS)

    Gary, J. Patrick

    1998-01-01

    Various issues associated with the "Testbed for Satellite and Terrestrial Interoperability (TSTI)" are presented in viewgraph form. Specific topics include: 1) General and specific scientific technical objectives; 2) ACTS experiment No. 118: 622 Mbps network tests between ATDNet and MAGIC via ACTS; 3) ATDNet SONET/ATM gigabit network; 4) Testbed infrastructure, collaborations and end sites in TSTI based evaluations; 5) the Trans-Pacific digital library experiment; and 6) ESDCD on-going network projects.

  13. Quiet Clean Short-Haul Experimental Engine (QCSEE) Under-the-Wing (UTW) Final Design Report

    NASA Technical Reports Server (NTRS)

    1977-01-01

    The QCSEE Program provides for the design, fabrication, and testing of two experimental high-bypass geared turbofan engines and propulsion systems for short-haul passenger aircraft. The overall objective of the program is to develop the propulsion technology required for future externally blown flap types of aircraft with engines located both under-the-wing and over-the-wing. This technology includes work in composite structures and digital engine controls.

  14. Learning in Home Care: A Digital Artifact as a Designated Boundary Object-in-Use

    ERIC Educational Resources Information Center

    Islind, Anna Sigridur; Lundh Snis, Ulrika

    2017-01-01

    Purpose: The aim of this paper is to understand how the role of an mHealth artifact plays out in home care settings. An mHealth artifact, in terms of a mobile app, was tested to see how the quality of home care work practice was enhanced and changed. The research question is: In what ways does an mHealth artifact re-shape a home care practice and…

  15. Simulating Optical Correlation on a Digital Image Processing

    NASA Astrophysics Data System (ADS)

    Denning, Bryan

    1998-04-01

    Optical Correlation is a useful tool for recognizing objects in video scenes. In this paper, we explore the characteristics of a composite filter known as the equal correlation peak synthetic discriminant function (ECP SDF). Although the ECP SDF is commonly used in coherent optical correlation systems, the authors simulated the operation of a correlator using an EPIX frame grabber/image processor board to complete this work. Issues pertaining to simulating correlation using an EPIX board will be discussed. Additionally, the ability of the ECP SDF to detect objects that have been subjected to inplane rotation and small scale changes will be addressed by correlating filters against true-class objects placed randomly within a scene. To test the robustness of the filters, the results of correlating the filter against false-class objects that closely resemble the true class will also be presented.

  16. MUST - An integrated system of support tools for research flight software engineering. [Multipurpose User-oriented Software Technology

    NASA Technical Reports Server (NTRS)

    Straeter, T. A.; Foudriat, E. C.; Will, R. W.

    1977-01-01

    The objectives of NASA's MUST (Multipurpose User-oriented Software Technology) program at Langley Research Center are to cut the cost of producing software which effectively utilizes digital systems for flight research. These objectives will be accomplished by providing an integrated system of support software tools for use throughout the research flight software development process. A description of the overall MUST program and its progress toward the release of a first MUST system will be presented. This release includes: a special interactive user interface, a library of subroutines, assemblers, a compiler, automatic documentation tools, and a test and simulation system.

  17. Difference between manual and digital measurements of dental arches of orthodontic patients.

    PubMed

    Jiménez-Gayosso, Sandra Isabel; Lara-Carrillo, Edith; López-González, Saraí; Medina-Solís, Carlo Eduardo; Scougall-Vilchis, Rogelio José; Hernández-Martínez, César Tadeo; Colomé-Ruiz, Gabriel Eduardo; Escoffié-Ramirez, Mauricio

    2018-06-01

    The objective of this study was to compare the differences between the measurements performed manually to those obtained using a digital model scanner of patients with orthodontic treatment.A cross-sectional study was performed in a sample of 30 study models from patients with permanent dentition who attended a university clinic between January 2010 and December 2015. For the digital measurement, a Maestro 3D Ortho Studio scanner (Italy) was used and Mitutoyo electronic Vernier calipers (Kawasaki, Japan) were used for manual measurement. The outcome variables were the measurements for maxillary intercanine width, mandibular intercanine width, maxillary intermolar width, mandibular intermolar width, overjet, overbite, maxillary arch perimeter, mandibular arch perimeter, and palate height. The independent variables, besides age and sex, were a series of arc characteristics. The Student t test, paired Student t test, and Pearson correlation in SPSS version 19 were used for the analysis.Of the models, 60% were from women. Two of nine measurements for pre-treatment and 6 of 9 measurements for post-treatment showed a difference. The variables that were different between the manual and digital measurements in the pre-treatment were maxillary intermolar width and palate height (P < .05). Post-treatment, differences were found in mandibular intercanine width, palate height, overjet, overbite, and maxillary and mandibular arch perimeter (P < .05).The models measured manually and digitally showed certain similarities for both vertical and transverse measurements. There are many advantages offered to the orthodontist, such as easy storage; savings in time and space; facilitating the reproducibility of information; and conferring the security of not deteriorating over time. Its main disadvantage is the cost.

  18. Short-Term and Working Memory Impairments in Early-Implanted, Long-Term Cochlear Implant Users Are Independent of Audibility and Speech Production

    PubMed Central

    AuBuchon, Angela M.; Pisoni, David B.; Kronenberger, William G.

    2015-01-01

    OBJECTIVES Determine if early-implanted, long-term cochlear implant (CI) users display delays in verbal short-term and working memory capacity when processes related to audibility and speech production are eliminated. DESIGN Twenty-three long-term CI users and 23 normal-hearing controls each completed forward and backward digit span tasks under testing conditions which differed in presentation modality (auditory or visual) and response output (spoken recall or manual pointing). RESULTS Normal-hearing controls reproduced more lists of digits than the CI users, even when the test items were presented visually and the responses were made manually via touchscreen response. CONCLUSIONS Short-term and working memory delays observed in CI users are not due to greater demands from peripheral sensory processes such as audibility or from overt speech-motor planning and response output organization. Instead, CI users are less efficient at encoding and maintaining phonological representations in verbal short-term memory utilizing phonological and linguistic strategies during memory tasks. PMID:26496666

  19. Developing Historic Building Information Modelling Guidelines and Procedures for Architectural Heritage in Ireland

    NASA Astrophysics Data System (ADS)

    Murphy, M.; Corns, A.; Cahill, J.; Eliashvili, K.; Chenau, A.; Pybus, C.; Shaw, R.; Devlin, G.; Deevy, A.; Truong-Hong, L.

    2017-08-01

    Cultural heritage researchers have recently begun applying Building Information Modelling (BIM) to historic buildings. The model is comprised of intelligent objects with semantic attributes which represent the elements of a building structure and are organised within a 3D virtual environment. Case studies in Ireland are used to test and develop the suitable systems for (a) data capture/digital surveying/processing (b) developing library of architectural components and (c) mapping these architectural components onto the laser scan or digital survey to relate the intelligent virtual representation of a historic structure (HBIM). While BIM platforms have the potential to create a virtual and intelligent representation of a building, its full exploitation and use is restricted to narrow set of expert users with access to costly hardware, software and skills. The testing of open BIM approaches in particular IFCs and the use of game engine platforms is a fundamental component for developing much wider dissemination. The semantically enriched model can be transferred into a WEB based game engine platform.

  20. Digital holographic tomography based on spectral interferometry.

    PubMed

    Yu, Lingfeng; Chen, Zhongping

    2007-10-15

    A digital holographic tomography system has been developed with the use of an inexpensive broadband light source and a fiber-based spectral interferometer. Multiple synthesized holograms (or object wave fields) of different wavelengths are obtained by transversely scanning a probe beam. The acquisition speed is improved compared with conventional wavelength-scanning digital holographic systems. The optical field of a volume around the object location is calculated by numerical diffraction from each synthesized hologram, and all such field volumes are numerically superposed to create the three-dimensional tomographic image. Experiments were performed to demonstrate the idea.

  1. The Integrity of Digital Information: Mechanics and Definitional Issues.

    ERIC Educational Resources Information Center

    Lynch, Clifford A.

    1994-01-01

    Considers issues regarding the migration of a system of literature into electronic formats. Highlights include integrity in an information distribution system; digest technology; tracings that permit detection of copied digital objects; verifying sources; digital signature technology and cryptography; electronic publishing; and intellectual…

  2. Assessing working memory in children with ADHD: Minor administration and scoring changes may improve digit span backward's construct validity.

    PubMed

    Wells, Erica L; Kofler, Michael J; Soto, Elia F; Schaefer, Hillary S; Sarver, Dustin E

    2018-01-01

    Pediatric ADHD is associated with impairments in working memory, but these deficits often go undetected when using clinic-based tests such as digit span backward. The current study pilot-tested minor administration/scoring modifications to improve digit span backward's construct and predictive validities in a well-characterized sample of children with ADHD. WISC-IV digit span was modified to administer all trials (i.e., ignore discontinue rule) and count digits rather than trials correct. Traditional and modified scores were compared to a battery of criterion working memory (construct validity) and academic achievement tests (predictive validity) for 34 children with ADHD ages 8-13 (M=10.41; 11 girls). Traditional digit span backward scores failed to predict working memory or KTEA-2 achievement (allns). Alternate administration/scoring of digit span backward significantly improved its associations with working memory reordering (r=.58), working memory dual-processing (r=.53), working memory updating (r=.28), and KTEA-2 achievement (r=.49). Consistent with prior work, these findings urge caution when interpreting digit span performance. Minor test modifications may address test validity concerns, and should be considered in future test revisions. Digit span backward becomes a valid measure of working memory at exactly the point that testing is traditionally discontinued. Copyright © 2017 Elsevier Ltd. All rights reserved.

  3. [Digital acoustic burglar alarm system using infrared radio remote control].

    PubMed

    Wang, Song-De; Zhao, Yan; Yao, Li-Ping; Zhang, Shuan-Ji

    2009-03-01

    Using butt emission infrared sensors, radio receiving and sending modules, double function integrated circuit with code and code translation, LED etc, a digital acoustic burglar alarm system using infrared radio to realize remote control was designed. It uses infrared ray invisible to eyes, composing area of radio distance. Once people and objects shelter the infrared ray, a testing signal will be output by the tester, and the sender will be triggered to work. The radio coding signal that sender sent is received by the receiver, then processed by a serial circuit. The control signal is output to trigger the sounder to give out an alarm signal, and the operator will be cued to notice this variation. At the same time, the digital display will be lighted and the alarm place will be watched. Digital coding technology is used, and a number of sub alarm circuits can joint the main receiver, so a lot of places can be monitored. The whole system features a module structure, with the property of easy alignment, stable operation, debug free and so on. The system offers an alarm range reaching 1 000 meters in all directions, and can be widely used in family, shop, storehouse, orchard and so on.

  4. Quantification of plume opacity by digital photography.

    PubMed

    Du, Ke; Rood, Mark J; Kim, Byung J; Kemme, Michael R; Franek, Bill; Mattison, Kevin

    2007-02-01

    The United States Environmental Protection Agency (USEPA) developed Method 9 to describe how plume opacity can be quantified by humans. However, use of observations by humans introduces subjectivity, and is expensive due to semiannual certification requirements of the observers. The Digital Opacity Method (DOM) was developed to quantify plume opacity at lower cost, with improved objectivity, and to provide a digital record. Photographs of plumes were taken with a calibrated digital camera under specified conditions. Pixel values from those photographs were then interpreted to quantify the plume's opacity using a contrast model and a transmission model. The contrast model determines plume opacity based on pixel values that are related to the change in contrast between two backgrounds that are located behind and next to the plume. The transmission model determines the plume's opacity based on pixel values that are related to radiances from the plume and its background. DOM was field tested with a smoke generator. The individual and average opacity errors of DOM were within the USEPA Method 9 acceptable error limits for both field campaigns. Such results are encouraging and support the use of DOM as an alternative to Method 9.

  5. General-purpose readout electronics for white neutron source at China Spallation Neutron Source

    NASA Astrophysics Data System (ADS)

    Wang, Q.; Cao, P.; Qi, X.; Yu, T.; Ji, X.; Xie, L.; An, Q.

    2018-01-01

    The under-construction White Neutron Source (WNS) at China Spallation Neutron Source is a facility for accurate measurements of neutron-induced cross section. Seven spectrometers are planned at WNS. As the physical objectives of each spectrometer are different, the requirements for readout electronics are not the same. In order to simplify the development of the readout electronics, this paper presents a general method for detector signal readout. This method has advantages of expansibility and flexibility, which makes it adaptable to most detectors at WNS. In the WNS general-purpose readout electronics, signals from any kinds of detectors are conditioned by a dedicated signal conditioning module corresponding to this detector, and then digitized by a common waveform digitizer with high speed and high precision (1 GSPS at 12-bit) to obtain the full waveform data. The waveform digitizer uses a field programmable gate array chip to process the data stream and trigger information in real time. PXI Express platform is used to support the functionalities of data readout, clock distribution, and trigger information exchange between digitizers and trigger modules. Test results show that the performance of the WNS general-purpose readout electronics can meet the requirements of the WNS spectrometers.

  6. STS-48 MS Buchli, eating crackers on OV-103's middeck, is captured by ESC

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-48 Mission Specialist (MS) James F. Buchli 'catches' goldfish snack crackers as they float in the weightless environment of the earth-orbiting Discovery, Orbiter Vehicle (OV) 103. Buchli's eating activity on the middeck was documented using the Electronic Still Camera (ESC). Crewmembers were testing the ESC as part of Development Test Objective (DTO) 648, Electronic Still Photography. The digital image was stored on a removable hard disk or small optical disk, and could be converted to a format suitable for downlink transmission. The ESC is making its initial appearance on this Space Shuttle mission.

  7. Cortical Merging in S1 as a Substrate for Tactile Input Grouping

    PubMed Central

    Zennou-Azogui, Yoh’I; Xerri, Christian

    2018-01-01

    Abstract Perception is a reconstruction process guided by rules based on knowledge about the world. Little is known about the neural implementation of the rules of object formation in the tactile sensory system. When two close tactile stimuli are delivered simultaneously on the skin, subjects feel a unique sensation, spatially centered between the two stimuli. Voltage-sensitive dye imaging (VSDi) and electrophysiological recordings [local field potentials (LFPs) and single units] were used to extract the cortical representation of two-point tactile stimuli in the primary somatosensory cortex of anesthetized Long-Evans rats. Although layer 4 LFP responses to brief costimulation of the distal region of two digits resembled the sum of individual responses, approximately one-third of single units demonstrated merging-compatible changes. In contrast to previous intrinsic optical imaging studies, VSD activations reflecting layer 2/3 activity were centered between the representations of the digits stimulated alone. This merging was found for every tested distance between the stimulated digits. We discuss this laminar difference as evidence that merging occurs through a buildup stream and depends on the superposition of inputs, which increases with successive stages of sensory processing. These findings show that layers 2/3 are involved in the grouping of sensory inputs. This process that could be inscribed in the cortical computing routine and network organization is likely to promote object formation and implement perception rules. PMID:29354679

  8. DIC-CAM recipe for reverse engineering

    NASA Astrophysics Data System (ADS)

    Romero-Carrillo, P.; Lopez-Alba, E.; Dorado, R.; Diaz-Garrido, F. A.

    2012-04-01

    Reverse engineering (RE) tries to model and manufacture an object from measurements one of a reference object. Modern optical measurement systems and computer aided engineering software have improved reverse engineering procedures. We detail the main RE steps from 3D digitalization by Digital Image Correlation to manufacturing. The previous description is complemented with an application example, which portrays the performance of RE. The differences between original and manufactured objects are less than 2 mm (close to the tool radius).

  9. Interferenceless coded aperture correlation holography-a new technique for recording incoherent digital holograms without two-wave interference.

    PubMed

    Vijayakumar, A; Rosen, Joseph

    2017-06-12

    Recording digital holograms without wave interference simplifies the optical systems, increases their power efficiency and avoids complicated aligning procedures. We propose and demonstrate a new technique of digital hologram acquisition without two-wave interference. Incoherent light emitted from an object propagates through a random-like coded phase mask and recorded directly without interference by a digital camera. In the training stage of the system, a point spread hologram (PSH) is first recorded by modulating the light diffracted from a point object by the coded phase masks. At least two different masks should be used to record two different intensity distributions at all possible axial locations. The various recorded patterns at every axial location are superposed in the computer to obtain a complex valued PSH library cataloged to its axial location. Following the training stage, an object is placed within the axial boundaries of the PSH library and the light diffracted from the object is once again modulated by the same phase masks. The intensity patterns are recorded and superposed exactly as the PSH to yield a complex hologram of the object. The object information at any particular plane is reconstructed by a cross-correlation between the complex valued hologram and the appropriate element of the PSH library. The characteristics and the performance of the proposed system were compared with an equivalent regular imaging system.

  10. Mental Representation of Spatial Cues During Spaceflight (3D-SPACE)

    NASA Astrophysics Data System (ADS)

    Clement, Gilles; Lathan, Corinna; Skinner, Anna; Lorigny, Eric

    2008-06-01

    The 3D-SPACE experiment is a joint effort between ESA and NASA to develop a simple virtual reality platform to enable astronauts to complete a series of tests while aboard the International Space Station (ISS). These tests will provide insights into the effects of the space environment on: (a) depth perception, by presenting 2D geometric illusions and 3D objects that subjects adjust with a finger trackball; (b) distance perception, by presenting natural or computer-generated 3D scenes where subjects estimate and report absolute distances or adjust distances; and (c) handwriting/drawing, by analyzing trajectories and velocities when subjects write or draw memorized objects with an electronic pen on a digitizing tablet. The objective of these tasks is to identify problems associated with 3D perception in astronauts with the goal of developing countermeasures to alleviate any associated performance risks. The equipment has been uploaded to the ISS in April 2008, and the first measurements should take place during Increment 17.

  11. Digital imaging of patterns of dental wear to diagnose bruxism in children.

    PubMed

    Restrepo, C; Peláez, A; Alvarez, E; Paucar, C; Abad, P

    2006-07-01

    The aim of this study was to evaluate and compare the area, perimeter, and form (D factor and fractal dimension) of the dental wear among bruxist and nonbruxist children with mixed dentition in order to determine if the dental wear may be used as criteria to diagnose bruxism. The children were 8 to 11 years old and were classified as bruxist or nonbruxist, according to anxiety level and temporomandibular disorders. Dental casts of the upper arch were obtained for the bruxist (n = 24) and the control (n = 29) group. The dental wear was measured in digital format and processed automatically. The complete and pathological dental wear was compared between the two groups, using the Student's t-test and Mann-Whitney test. Statistically significant differences were observed between the two groups, with a higher area, perimeter, and more irregular form of the pathological dental wear among the bruxist group. Regarding complete dental wear, differences were only significant for the D factor (an un-dimensional quantitative parameter which produces a relation between the area and the perimeter of an object). Digital imaging of dental wear may be used as criteria to diagnose bruxism in children with mixed dentition after making an analysis of the area, perimeter, and irregularity of the form of pathological dental wear.

  12. Suitability of digital camcorders for virtual reality image data capture

    NASA Astrophysics Data System (ADS)

    D'Apuzzo, Nicola; Maas, Hans-Gerd

    1998-12-01

    Today's consumer market digital camcorders offer features which make them appear quite interesting devices for virtual reality data capture. The paper compares a digital camcorder with an analogue camcorder and a machine vision type CCD camera and discusses the suitability of these three cameras for virtual reality applications. Besides the discussion of technical features of the cameras, this includes a detailed accuracy test in order to define the range of applications. In combination with the cameras, three different framegrabbers are tested. The geometric accuracy potential of all three cameras turned out to be surprisingly large, and no problems were noticed in the radiometric performance. On the other hand, some disadvantages have to be reported: from the photogrammetrists point of view, the major disadvantage of most camcorders is the missing possibility to synchronize multiple devices, limiting the suitability for 3-D motion data capture. Moreover, the standard video format contains interlacing, which is also undesirable for all applications dealing with moving objects or moving cameras. Further disadvantages are computer interfaces with functionality, which is still suboptimal. While custom-made solutions to these problems are probably rather expensive (and will make potential users turn back to machine vision like equipment), this functionality could probably be included by the manufacturers at almost zero cost.

  13. Best Practices in Digital Object Development for Education: Promoting Excellence and Innovation in Instructional Quality and Assessment

    ERIC Educational Resources Information Center

    Reece, Amanda A.

    2016-01-01

    A program of development of online learning resources should provide content, resources, support and activities to promote excellence and innovation in instructional quality and assessment. This article provides details on five best practices in digital object development for teaching and learning. In addition, an evaluation of the learning object…

  14. Integrating Digital Learning Objects in the Classroom: A Need for Educational Leadership

    ERIC Educational Resources Information Center

    Janson, Annick; Janson, Robin

    2009-01-01

    In this article, Annick Janson and Robin Janson introduce research from the Microsoft New Zealand's Partners in Learning Programme by documenting the impact of digital learning objects (DLOs) on educational practice. Janson and Janson describe the impact of DLOs on the teaching practice of a primary school in New Zealand, tracing the effects of…

  15. Evaluation of a Digital Learning Object for the Monty Hall Dilemma

    ERIC Educational Resources Information Center

    DiBattista, David

    2011-01-01

    The Monty Hall dilemma (MHD) is a remarkably difficult probability problem with a counterintuitive solution. Undergraduate students used an interactive digital learning object that provided a set-based, animated explanation of the solution to the MHD and let them play games designed to increase understanding of the solution. More than 60% of users…

  16. Cognitive performance is associated with macronutrient intake in healthy young and middle-aged adults.

    PubMed

    Zhang, Jian; Mckeown, Robert E; Muldoon, Matthew F; Tang, Shenghui

    2006-01-01

    The objective was to examine whether dietary intakes of macronutrients are associated with neuropsychological performance. Study participants were 3960 adults aged 20-59 years, who completed three neuropsychological tests and a 24-hour dietary recall as a part of the Third National Health and Nutrition Examination Survey, 1988-1994. Poor performance was defined as the test score below gender-specific 15th percentile. While holding the energy percentages from different macronutrients, additional 100 kcal intake of energy was associated with a reduced odds of poor performance on serial digital learning test (OR = 0.98, 95% CI = 0.96, 0.99) and symbol digital substitution test (OR = 0.97, 95% CI = 0.96, 0.99). Compared with equivalent energy from carbohydrates, each 5% of energy from poly-unsaturated fatty acids (PUFA) or total fat was associated with a reduced OR of poor performance on simple reaction time test (PUFA: OR = 0.77, 95% CI = 0.63-0.95 and total fat: OR = 0.93, 95% CI = 0.87, 0.99). Poor global cognition was associated with an additional intake of 100 mg cholesterol (OR = 1.14, 95% CI = 1.05, 1.23). These associations were more salient in men. Habitual intake of macronutrients is weakly but significantly associated with cognitive functioning. These relationships are more evident in men.

  17. 77 FR 50720 - Test Documentation for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Test Documentation for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1207, ``Test Documentation for Digital... practices for test documentation for software and computer systems as described in the Institute of...

  18. Preservice Teachers and Self-Assessing Digital Competence

    ERIC Educational Resources Information Center

    Maderick, Joseph A.; Zhang, Shaoan; Hartley, Kendall; Marchand, Gwen

    2016-01-01

    This study compares matched surveys of subjective self-assessment and objective assessment on seven domains of digital competence for preservice teachers at a large Southwest public university. The results, consistent with earlier studies, confirm that the participating preservice teachers inaccurately self-assessed their digital competence. The…

  19. Digital Competence Assessment: A Proposal for Operationalizing the Critical Dimension

    ERIC Educational Resources Information Center

    Cortoni, Ida; LoPresti, Veronica; Cervelli, Pierluigi

    2015-01-01

    The European Commission considers the development of digital competences a strategic action to spread and to develop a more active digital participation of citizens. The objective is to increase the level of digital competence in the European citizens up to 2015 and to reduce the number of those who don't use new technologies and don't surf the…

  20. Single-beam, dual-view digital holographic interferometry for biomechanical strain measurements of biological objects

    NASA Astrophysics Data System (ADS)

    Pantelić, Dejan V.; Grujić, Dušan Ž.; Vasiljević, Darko M.

    2014-12-01

    We describe a method for dual-view biomechanical strain measurements of highly asymmetrical biological objects, like teeth or bones. By using a spherical mirror, we were able to simultaneously record a digital hologram of the object itself and the mirror image of its (otherwise invisible) rear side. A single laser beam was sufficient to illuminate both sides of the object, and to provide a reference beam. As a result, the system was mechanically very stable, enabling long exposure times (up to 2 min) without the need for vibration isolation. The setup is simple to construct and adjust, and can be used to interferometrically observe any object that is smaller than the mirror diameter. Parallel data processing on a CUDA-enabled (compute unified device architecture) graphics card was used to reconstruct digital holograms and to further correct image distortion. We used the setup to measure the deformation of a tooth due to mastication forces. The finite-element method was used to compare experimental results and theoretical predictions.

  1. Single-beam, dual-view digital holographic interferometry for biomechanical strain measurements of biological objects.

    PubMed

    Pantelić, Dejan V; Grujić, Dušan Ž; Vasiljević, Darko M

    2014-12-01

    We describe a method for dual-view biomechanical strain measurements of highly asymmetrical biological objects, like teeth or bones. By using a spherical mirror, we were able to simultaneously record a digital hologram of the object itself and the mirror image of its (otherwise invisible) rear side. A single laser beam was sufficient to illuminate both sides of the object, and to provide a reference beam. As a result, the system was mechanically very stable, enabling long exposure times (up to 2 min) without the need for vibration isolation. The setup is simple to construct and adjust, and can be used to interferometrically observe any object that is smaller than the mirror diameter. Parallel data processing on a CUDA-enabled (compute unified device architecture) graphics card was used to reconstruct digital holograms and to further correct image distortion. We used the setup to measure the deformation of a tooth due to mastication forces. The finite-element method was used to compare experimental results and theoretical predictions.

  2. Antiscatter grid use in pediatric digital tomosynthesis imaging†

    PubMed Central

    King, Jenna M.; Reed, Martin

    2011-01-01

    The objective of this study was to assess the effect of antiscatter grid use on tomosynthesis image quality. We performed an observer study that rated the image quality of digital tomosynthesis scout radiographs and slice images of a Leeds TO.20 contrast‐detail test object embedded in acrylic with and without a grid. We considered 10, 15, 20 and 25 cm of acrylic to represent the wide range of patient thicknesses encountered in pediatric imaging. We also acquired and rated images without a grid at an increased patient dose. The readers counted the total number of visible details in each image as a measure of relative image quality. We observed that the antiscatter grid improves tomosynthesis image quality compared to the grid‐out case, which received image quality scores similar to grid‐in radiography. Our results suggest that, in order to achieve the best image quality in exchange for the increase in patient dose, it may often be appropriate to include an antiscatter grid for pediatric tomosynthesis imaging, particularly if the patient thickness is greater than 10 cm. PACS number: 87.57.‐s PMID:22089021

  3. The applicability of holography in forensic identification: a fusion of the traditional optical technique and digital technique.

    PubMed

    Biwasaka, Hitoshi; Saigusa, Kiyoshi; Aoki, Yasuhiro

    2005-03-01

    In this study, the applicability of holography in the 3-dimensional recording of forensic objects such as skulls and mandibulae, and the accuracy of the reconstructed 3-D images, were examined. The virtual holographic image, which records the 3-dimensional data of the original object, is visually observed on the other side of the holographic plate, and reproduces the 3-dimensional shape of the object well. Another type of holographic image, the real image, is focused on a frosted glass screen, and cross-sectional images of the object can be observed. When measuring the distances between anatomical reference points using an image-processing software, the average deviations in the holographic images as compared to the actual objects were less than 0.1 mm. Therefore, holography could be useful as a 3-dimensional recording method of forensic objects. Two superimposition systems using holographic images were examined. In the 2D-3D system, the transparent virtual holographic image of an object is directly superimposed onto the digitized photograph of the same object on the LCD monitor. On the other hand, in the video system, the holographic image captured by the CCD camera is superimposed onto the digitized photographic image using a personal computer. We found that the discrepancy between the outlines of the superimposed holographic and photographic dental images using the video system was smaller than that using the 2D-3D system. Holography seemed to perform comparably to the computer graphic system; however, a fusion with the digital technique would expand the utility of holography in superimposition.

  4. Mechanical properties of the human hand digits: Age-related differences

    PubMed Central

    Park, Jaebum; Pazin, Nemanja; Friedman, Jason; Zatsiorsky, Vladimir M.; Latash, Mark L.

    2014-01-01

    Background Mechanical properties of human digits may have significant implications for the hand function. We quantified several mechanical characteristics of individual digits in young and older adults. Methods Digit tip friction was measured at several normal force values using a method of induced relative motion between the digit tip and the object surface. A modified quick-release paradigm was used to estimate digit apparent stiffness, damping, and inertial parameters. The subjects grasped a vertical handle instrumented with force/moment sensors using a prismatic grasp with four digits; the handle was fixed to the table. Unexpectedly, one of the sensors yielded leading to a quick displacement of the corresponding digit. A second-order, linear model was used to fit the force/displacement data. Findings Friction of the digit pads was significantly lower in older adults. The apparent stiffness coefficient values were higher while the damping coefficients were lower in older adults leading to lower damping ratio. The damping ratio was above unity for most data in young adults and below unity for older adults. Quick release of a digit led to force changes in other digits of the hand, likely due to inertial hand properties. These phenomena of “mechanical enslaving” were smaller in older adults although no significant difference was found in the inertial parameter in the two groups. Interpretations The decreased friction and damping ratio present challenges for the control of everyday prehensile tasks. They may lead to excessive digit forces and low stability of the grasped object. PMID:24355703

  5. Optical digital microscopy for cyto- and hematological studies in vitro

    NASA Astrophysics Data System (ADS)

    Ganilova, Yu. A.; Dolmashkin, A. A.; Doubrovski, V. A.; Yanina, I. Yu.; Tuchin, V. V.

    2013-08-01

    The dependence of the spatial resolution and field of view of an optical microscope equipped with a CCD camera on the objective magnification has been experimentally investigated. Measurement of these characteristics has shown that a spatial resolution of 20-25 px/μm at a field of view of about 110 μm is quite realistic; this resolution is acceptable for a detailed study of the processes occurring in cell. It is proposed to expand the dynamic range of digital camera by measuring and approximating its light characteristics with subsequent plotting of the corresponding calibration curve. The biological objects of study were human adipose tissue cells, as well as erythrocytes and their immune complexes in human blood; both objects have been investigated in vitro. Application of optical digital microscopy for solving specific problems of cytology and hematology can be useful in both biomedical studies in experiments with objects of nonbiological origin.

  6. Electro-cutaneous stimulation on the palm elicits referred sensations on intact but not on amputated digits

    NASA Astrophysics Data System (ADS)

    D'Alonzo, M.; Engels, L. F.; Controzzi, M.; Cipriani, C.

    2018-02-01

    Objective. Grasping and manipulation control critically depends on tactile feedback. Without this feedback, the ability for fine control of a prosthesis is limited in upper limb amputees. Early studies have shown that non-invasive electro-cutaneous stimulation (ES) can induce referred sensations that are spread to a wider and/or more distant area, with respect to the electrodes. Building on this, we sought to exploit this effect to provide somatotopically matched sensory feedback to people with partial hand (digital) amputations. Approach. For the first time, this work investigated the possibility of inducing referred sensations in the digits by activating the palmar nerves. Specifically, we electrically stimulated 18 sites on the palm of non-amputees to evaluate the effects of sites and stimulation parameters on modality, magnitude, and location of the evoked sensations. We performed similar tests with partial hand amputees by testing those sites that had most consistently elicited referred sensations in non-amputees. Main results. We demonstrated referred sensations in non-amputees from all stimulation sites in one form or another. Specifically, the stimulation of 16 of the 18 sites gave rise to reliable referred sensations. Amputees experienced referred sensations to unimpaired digits, just like non-amputees, but we were unable to evoke referred sensations in their missing digits: none of them reported sensations that extended beyond the tip of the stump. Significance. The possibility of eliciting referred sensations on the digits may be exploited in haptic systems for providing touch sensations without obstructing the fingertips or their movements. The study also suggests that the phenomenon of referred sensations through ES may not be exploited for partial hand prostheses, and it invites researchers to explore alternative approaches. Finally, the results seem to confirm previous studies suggesting that the stumps in partial hand amputees partially acquire the role of the missing fingertips, physiologically and cognitively.

  7. High-speed single-pixel digital holography

    NASA Astrophysics Data System (ADS)

    González, Humberto; Martínez-León, Lluís.; Soldevila, Fernando; Araiza-Esquivel, Ma.; Tajahuerce, Enrique; Lancis, Jesús

    2017-06-01

    The complete phase and amplitude information of biological specimens can be easily determined by phase-shifting digital holography. Spatial light modulators (SLMs) based on liquid crystal technology, with a frame-rate around 60 Hz, have been employed in digital holography. In contrast, digital micro-mirror devices (DMDs) can reach frame rates up to 22 kHz. A method proposed by Lee to design computer generated holograms (CGHs) permits the use of such binary amplitude modulators as phase-modulation devices. Single-pixel imaging techniques record images by sampling the object with a sequence of micro-structured light patterns and using a simple photodetector. Our group has reported some approaches combining single-pixel imaging and phase-shifting digital holography. In this communication, we review these techniques and present the possibility of a high-speed single-pixel phase-shifting digital holography system with phase-encoded illumination. This system is based on a Mach-Zehnder interferometer, with a DMD acting as the modulator for projecting the sampling patterns on the object and also being used for phase-shifting. The proposed sampling functions are phaseencoded Hadamard patterns generated through a Lee hologram approach. The method allows the recording of the complex amplitude distribution of an object at high speed on account of the high frame rates of the DMD. Reconstruction may take just a few seconds. Besides, the optical setup is envisaged as a true adaptive system, which is able to measure the aberration induced by the optical system in the absence of a sample object, and then to compensate the wavefront in the phasemodulation stage.

  8. Object-oriented feature extraction approach for mapping supraglacial debris in Schirmacher Oasis using very high-resolution satellite data

    NASA Astrophysics Data System (ADS)

    Jawak, Shridhar D.; Jadhav, Ajay; Luis, Alvarinho J.

    2016-05-01

    Supraglacial debris was mapped in the Schirmacher Oasis, east Antarctica, by using WorldView-2 (WV-2) high resolution optical remote sensing data consisting of 8-band calibrated Gram Schmidt (GS)-sharpened and atmospherically corrected WV-2 imagery. This study is a preliminary attempt to develop an object-oriented rule set to extract supraglacial debris for Antarctic region using 8-spectral band imagery. Supraglacial debris was manually digitized from the satellite imagery to generate the ground reference data. Several trials were performed using few existing traditional pixel-based classification techniques and color-texture based object-oriented classification methods to extract supraglacial debris over a small domain of the study area. Multi-level segmentation and attributes such as scale, shape, size, compactness along with spectral information from the data were used for developing the rule set. The quantitative analysis of error was carried out against the manually digitized reference data to test the practicability of our approach over the traditional pixel-based methods. Our results indicate that OBIA-based approach (overall accuracy: 93%) for extracting supraglacial debris performed better than all the traditional pixel-based methods (overall accuracy: 80-85%). The present attempt provides a comprehensive improved method for semiautomatic feature extraction in supraglacial environment and a new direction in the cryospheric research.

  9. Study on the system-level test method of digital metering in smart substation

    NASA Astrophysics Data System (ADS)

    Zhang, Xiang; Yang, Min; Hu, Juan; Li, Fuchao; Luo, Ruixi; Li, Jinsong; Ai, Bing

    2017-03-01

    Nowadays, the test methods of digital metering system in smart substation are used to test and evaluate the performance of a single device, but these methods can only effectively guarantee the accuracy and reliability of the measurement results of a digital metering device in a single run, it does not completely reflect the performance when each device constitutes a complete system. This paper introduced the shortages of the existing test methods. A system-level test method of digital metering in smart substation was proposed, and the feasibility of the method was proved by the actual test.

  10. Accuracy and consistency of weights provided by home bathroom scales

    PubMed Central

    2013-01-01

    Background Self-reported body weight is often used for calculation of Body Mass Index because it is easy to collect. Little is known about sources of error introduced by using bathroom scales to measure weight at home. The objective of this study was to evaluate the accuracy and consistency of digital versus dial-type bathroom scales commonly used for self-reported weight. Methods Participants brought functioning bathroom scales (n = 18 dial-type, n = 43 digital-type) to a central location. Trained researchers assessed accuracy and consistency using certified calibration weights at 10 kg, 25 kg, 50 kg, 75 kg, 100 kg, and 110 kg. Data also were collected on frequency of calibration, age and floor surface beneath the scale. Results All participants reported using their scale on hard surface flooring. Before calibration, all digital scales displayed 0, but dial scales displayed a mean absolute initial weight of 0.95 (1.9 SD) kg. Digital scales accurately weighed test loads whereas dial-type scale weights differed significantly (p < 0.05). Imprecision of dial scales was significantly greater than that of digital scales at all weights (p < 0.05). Accuracy and precision did not vary by scale age. Conclusions Digital home bathroom scales provide sufficiently accurate and consistent weights for public health research. Reminders to zero scales before each use may further improve accuracy of self-reported weight. PMID:24341761

  11. Digital curation and online resources: digital scanning of surgical tools at the royal college of physicians and surgeons of Glasgow for an open university learning resource.

    PubMed

    Earley, Kirsty; Livingstone, Daniel; Rea, Paul M

    2017-01-01

    Collection preservation is essential for the cultural status of any city. However, presenting a collection publicly risks damage. Recently this drawback has been overcome by digital curation. Described here is a method of digitisation using photogrammetry and virtual reality software. Items were selected from the Royal College of Physicians and Surgeons of Glasgow archives, and implemented into an online learning module for the Open University. Images were processed via Agisoft Photoscan, Autodesk Memento, and Garden Gnome Object 2VR. Although problems arose due to specularity, 2VR digital models were developed for online viewing. Future research must minimise the difficulty of digitising specular objects.

  12. Digital Microdroplet Ejection Technology-Based Heterogeneous Objects Prototyping

    PubMed Central

    Yang, Jiquan; Feng, Chunmei; Yang, Jianfei; Zhu, Liya; Guo, Aiqing

    2016-01-01

    An integrate fabrication framework is presented to build heterogeneous objects (HEO) using digital microdroplets injecting technology and rapid prototyping. The heterogeneous materials part design and manufacturing method in structure and material was used to change the traditional process. The net node method was used for digital modeling that can configure multimaterials in time. The relationship of material, color, and jetting nozzle was built. The main important contributions are to combine the structure, material, and visualization in one process and give the digital model for manufacture. From the given model, it is concluded that the method is effective for HEO. Using microdroplet rapid prototyping and the model given in the paper HEO could be gotten basically. The model could be used in 3D biomanufacturing. PMID:26981110

  13. Single-shot digital holography by use of the fractional Talbot effect.

    PubMed

    Martínez-León, Lluís; Araiza-E, María; Javidi, Bahram; Andrés, Pedro; Climent, Vicent; Lancis, Jesús; Tajahuerce, Enrique

    2009-07-20

    We present a method for recording in-line single-shot digital holograms based on the fractional Talbot effect. In our system, an image sensor records the interference between the light field scattered by the object and a properly codified parallel reference beam. A simple binary two-dimensional periodic grating is used to codify the reference beam generating a periodic three-step phase distribution over the sensor plane by fractional Talbot effect. This provides a method to perform single-shot phase-shifting interferometry at frame rates only limited by the sensor capabilities. Our technique is well adapted for dynamic wavefront sensing applications. Images of the object are digitally reconstructed from the digital hologram. Both computer simulations and experimental results are presented.

  14. Digital Microdroplet Ejection Technology-Based Heterogeneous Objects Prototyping.

    PubMed

    Li, Na; Yang, Jiquan; Feng, Chunmei; Yang, Jianfei; Zhu, Liya; Guo, Aiqing

    2016-01-01

    An integrate fabrication framework is presented to build heterogeneous objects (HEO) using digital microdroplets injecting technology and rapid prototyping. The heterogeneous materials part design and manufacturing method in structure and material was used to change the traditional process. The net node method was used for digital modeling that can configure multimaterials in time. The relationship of material, color, and jetting nozzle was built. The main important contributions are to combine the structure, material, and visualization in one process and give the digital model for manufacture. From the given model, it is concluded that the method is effective for HEO. Using microdroplet rapid prototyping and the model given in the paper HEO could be gotten basically. The model could be used in 3D biomanufacturing.

  15. Optical scanning holography based on compressive sensing using a digital micro-mirror device

    NASA Astrophysics Data System (ADS)

    A-qian, Sun; Ding-fu, Zhou; Sheng, Yuan; You-jun, Hu; Peng, Zhang; Jian-ming, Yue; xin, Zhou

    2017-02-01

    Optical scanning holography (OSH) is a distinct digital holography technique, which uses a single two-dimensional (2D) scanning process to record the hologram of a three-dimensional (3D) object. Usually, these 2D scanning processes are in the form of mechanical scanning, and the quality of recorded hologram may be affected due to the limitation of mechanical scanning accuracy and unavoidable vibration of stepper motor's start-stop. In this paper, we propose a new framework, which replaces the 2D mechanical scanning mirrors with a Digital Micro-mirror Device (DMD) to modulate the scanning light field, and we call it OSH based on Compressive Sensing (CS) using a digital micro-mirror device (CS-OSH). CS-OSH can reconstruct the hologram of an object through the use of compressive sensing theory, and then restore the image of object itself. Numerical simulation results confirm this new type OSH can get a reconstructed image with favorable visual quality even under the condition of a low sample rate.

  16. Accuracy concerns in digital speckle photography combined with Fresnel digital holographic interferometry

    NASA Astrophysics Data System (ADS)

    Zhao, Yuchen; Zemmamouche, Redouane; Vandenrijt, Jean-François; Georges, Marc P.

    2018-05-01

    A combination of digital holographic interferometry (DHI) and digital speckle photography (DSP) allows in-plane and out-of-plane displacement measurement between two states of an object. The former can be determined by correlating the two speckle patterns whereas the latter is given by the phase difference obtained from DHI. We show that the amplitude of numerically reconstructed object wavefront obtained from Fresnel in-line digital holography (DH), in combination with phase shifting techniques, can be used as speckle patterns in DSP. The accuracy of in-plane measurement is improved after correcting the phase errors induced by reference wave during reconstruction process. Furthermore, unlike conventional imaging system, Fresnel DH offers the possibility to resize the pixel size of speckle patterns situated on the reconstruction plane under the same optical configuration simply by zero-padding the hologram. The flexibility of speckle size adjustment in Fresnel DH ensures the accuracy of estimation result using DSP.

  17. Evolution of Scientific and Technical Information Distribution

    NASA Technical Reports Server (NTRS)

    Esler, Sandra; Nelson, Michael L.

    1998-01-01

    World Wide Web (WWW) and related information technologies are transforming the distribution of scientific and technical information (STI). We examine 11 recent, functioning digital libraries focusing on the distribution of STI publications, including journal articles, conference papers, and technical reports. We introduce 4 main categories of digital library projects: based on the architecture (distributed vs. centralized) and the contributor (traditional publisher vs. authoring individual/organization). Many digital library prototypes merely automate existing publishing practices or focus solely on the digitization of the publishing cycle output, not sampling and capturing elements of the input. Still others do not consider for distribution the large body of "gray literature." We address these deficiencies in the current model of STI exchange by suggesting methods for expanding the scope and target of digital libraries by focusing on a greater source of technical publications and using "buckets," an object-oriented construct for grouping logically related information objects, to include holdings other than technical publications.

  18. Authenticity in a Digital Environment.

    ERIC Educational Resources Information Center

    Cullen, Charles T.; Hirtle, Peter B.; Levy, David; Lynch, Clifford A.; Rothenberg, Jeff

    On January 24, 2000, the Council on Library and Information Resources (CLIR) convened a group of experts from different domains of the information resources community to address the question, "What is an authentic digital object?" Five writers--an archivist, a digital library expert, a documentary editor and special collections…

  19. Method of estimation of scanning system quality

    NASA Astrophysics Data System (ADS)

    Larkin, Eugene; Kotov, Vladislav; Kotova, Natalya; Privalov, Alexander

    2018-04-01

    Estimation of scanner parameters is an important part in developing electronic document management system. This paper suggests considering the scanner as a system that contains two main channels: a photoelectric conversion channel and a channel for measuring spatial coordinates of objects. Although both of channels consist of the same elements, the testing of their parameters should be executed separately. The special structure of the two-dimensional reference signal is offered for this purpose. In this structure, the fields for testing various parameters of the scanner are sp atially separated. Characteristics of the scanner are associated with the loss of information when a document is digitized. The methods to test grayscale transmitting ability, resolution and aberrations level are offered.

  20. Creating an EPICS Based Test Stand Development System for a BPM Digitizer of the Linac Coherent Light Source

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Not Available

    2011-06-22

    The Linac Coherent Light Source (LCLS) is required to deliver a high quality electron beam for producing coherent X-rays. As a result, high resolution beam position monitoring is required. The Beam Position Monitor (BPM) digitizer acquires analog signals from the beam line and digitizes them to obtain beam position data. Although Matlab is currently being used to test the BPM digitizer?s functions and capability, the Controls Department at SLAC prefers to use Experimental Physics and Industrial Control Systems (EPICS). This paper discusses the transition of providing similar as well as enhanced functionalities, than those offered by Matlab, to test themore » digitizer. Altogether, the improved test stand development system can perform mathematical and statistical calculations with the waveform signals acquired from the digitizer and compute the fast Fourier transform (FFT) of the signals. Finally, logging of meaningful data into files has been added.« less

  1. Optimisation of the digital radiographic imaging of suspected non-accidental injury

    NASA Astrophysics Data System (ADS)

    Offiah, Amaka

    Aim: To optimise the digital (radiographic) imaging of children presenting with suspected non-accidental injury (NAI). Objectives: (i) To evaluate existing radiographic quality criteria, and to develop a more suitable system if these are found to be inapplicable to skeletal surveys obtained in suspected NAI. (ii) To document differences in image quality between conventional film-screen and the recently installed Fuji5000R computed radiography (CR) system at Great Ormond Street Hospital for Children, (iii) To document the extent of variability in the standard of skeletal surveys obtained in the UK for suspected NAI. (iv) To determine those radiographic parameters which yield the highest diagnostic accuracy, while still maintaining acceptable radiation dose to the child, (v) To determine how varying degrees of edge-enhancement affect diagnostic accuracy. (vi) To establish the accuracy of soft compared to hard copy interpretation of images in suspected NAI. Materials and Methods: (i) and (ii) Retrospective analysis of 286 paediatric lateral spine radiographs by two observers based on the Commission of European Communities (CEC) quality criteria, (iii) Review of the skeletal surveys of 50 consecutive infants referred from hospitals throughout the United Kingdom (UK) with suspected NAI. (iv) Phantom studies. Leeds TO. 10 and TO. 16 test objects were used to compare the relationship between film density, exposure parameters and visualisation of object details, (iv) Clinical study. Anteroposterior and lateral post mortem skull radiographs of six consecutive infants were obtained at various exposures. Six observers independently scored the images based on visualisation of five criteria, (v) and (vi) A study of diagnostic accuracy in which six observers independently interpreted 50 radiographs from printed copies (with varying degrees of edge-enhancement) and from a monitor. Results: The CEC criteria are useful for optimisation of imaging parameters and allow the detection of differences in quality of film-screen and digital images. There is much variability in the quality and number of radiographs performed as part of skeletal surveys in the UK for suspected NAI. The Leeds test objects are either not sensitive enough (TO. 10) or perhaps over sensitive (TO. 16) for the purposes of this project. Furthermore, the minimum spatial resolution required for digital imaging in NAI has not been established. Therefore the objective interpretation of phantom studies is difficult. There is scope for reduction of radiation dose to children with no effect on image quality. Diagnostic accuracy (fracture detection) in suspected NAI is generally low, and is not affected by image display modality. Conclusions: The CEC quality criteria are not applicable to the assessment of clinical image quality. A national protocol for skeletal surveys in NAI is required. Dedicated training, close supervision, collaboration and consistent exposure of radiologists to cases of NAI should improve diagnostic accuracy. The potential exists for dose reduction when performing skeletal surveys in children and infants with suspected NAI. Future studies should address this issue.

  2. Object extraction in photogrammetric computer vision

    NASA Astrophysics Data System (ADS)

    Mayer, Helmut

    This paper discusses state and promising directions of automated object extraction in photogrammetric computer vision considering also practical aspects arising for digital photogrammetric workstations (DPW). A review of the state of the art shows that there are only few practically successful systems on the market. Therefore, important issues for a practical success of automated object extraction are identified. A sound and most important powerful theoretical background is the basis. Here, we particularly point to statistical modeling. Testing makes clear which of the approaches are suited best and how useful they are for praxis. A key for commercial success of a practical system is efficient user interaction. As the means for data acquisition are changing, new promising application areas such as extremely detailed three-dimensional (3D) urban models for virtual television or mission rehearsal evolve.

  3. Development of the ECOSAR P-Band Synthetic Aperture Radar

    NASA Technical Reports Server (NTRS)

    Rincon, R. F.; Fatoyinbo, T.; Ranson, K. J.; Sun, G.; Deshpande, M.; Hale, R. D.; Bhat, A.; Perrine, M.; DuToit, C. F.; Bonds, Q.; hide

    2012-01-01

    This paper describes objectives and recent progress on the development of the EcoSAR, a new P-band airborne radar instrument being developed at the NASA/ Goddard Space Flight Center (GSFC) for the polarimetric and interferometric measurements of ecosystem structure and biomass. These measurements support science requirements for the study of the carbon cycle and its relationship to climate change. The instrument is scheduled to be completed and flight tested in 2013. Index Terms SAR, Digital Beamforming, Interferometry.

  4. A malaria diagnostic tool based on computer vision screening and visualization of Plasmodium falciparum candidate areas in digitized blood smears.

    PubMed

    Linder, Nina; Turkki, Riku; Walliander, Margarita; Mårtensson, Andreas; Diwan, Vinod; Rahtu, Esa; Pietikäinen, Matti; Lundin, Mikael; Lundin, Johan

    2014-01-01

    Microscopy is the gold standard for diagnosis of malaria, however, manual evaluation of blood films is highly dependent on skilled personnel in a time-consuming, error-prone and repetitive process. In this study we propose a method using computer vision detection and visualization of only the diagnostically most relevant sample regions in digitized blood smears. Giemsa-stained thin blood films with P. falciparum ring-stage trophozoites (n = 27) and uninfected controls (n = 20) were digitally scanned with an oil immersion objective (0.1 µm/pixel) to capture approximately 50,000 erythrocytes per sample. Parasite candidate regions were identified based on color and object size, followed by extraction of image features (local binary patterns, local contrast and Scale-invariant feature transform descriptors) used as input to a support vector machine classifier. The classifier was trained on digital slides from ten patients and validated on six samples. The diagnostic accuracy was tested on 31 samples (19 infected and 12 controls). From each digitized area of a blood smear, a panel with the 128 most probable parasite candidate regions was generated. Two expert microscopists were asked to visually inspect the panel on a tablet computer and to judge whether the patient was infected with P. falciparum. The method achieved a diagnostic sensitivity and specificity of 95% and 100% as well as 90% and 100% for the two readers respectively using the diagnostic tool. Parasitemia was separately calculated by the automated system and the correlation coefficient between manual and automated parasitemia counts was 0.97. We developed a decision support system for detecting malaria parasites using a computer vision algorithm combined with visualization of sample areas with the highest probability of malaria infection. The system provides a novel method for blood smear screening with a significantly reduced need for visual examination and has a potential to increase the throughput in malaria diagnostics.

  5. How to Determine the Centre of Mass of Bodies from Image Modelling

    ERIC Educational Resources Information Center

    Dias, Marco Adriano; Carvalho, Paulo Simeão; Rodrigues, Marcelo

    2016-01-01

    Image modelling is a recent technique in physics education that includes digital tools for image treatment and analysis, such as digital stroboscopic photography (DSP) and video analysis software. It is commonly used to analyse the motion of objects. In this work we show how to determine the position of the centre of mass (CM) of objects with…

  6. The utility of six over-the-counter (home) pregnancy tests.

    PubMed

    Cole, Laurence A

    2011-08-01

    The home pregnancy market is rapidly evolving. It has moved from detection of pregnancy on the day of missed menstrual bleeding, to detection claims 4 days prior. It is moving from all manual tests to digital tests, with a monitor reading the bands and informing women they are pregnant. A thorough study is needed to investigate the validity of claims and evolving usefulness of devices. Studies were proposed to examine the sensitivity and specificity of home tests and their abilities to detect pregnancy. Methods examined the abilities of tests to detect human chorionic gonadotropin (hCG), hyperglycosylated hCG, free β-subunit, a mixture of these antigens in 40 individual early pregnancy urines. Using a mixture of hCG, hyperglycosylated hCG and free β-subunit typical for early pregnancy, the sensitivity of the First Response manual and digital tests was 5.5 mIU/mL, while the sensitivities of the EPT and ClearBlue brand manual and digital tests was 22 mIU/mL. On further evaluation, the First Response manual and digital tests both detected 97% of 120 pregnancies on the day of missed menstrual bleeding. The EPT manual and digital devices detected 54% and 67% of pregnancies, respectively, and the ClearBlue manual and digital devices detected 64% and 54% of pregnancies, respectively. First Response manual and digital claim >99% detection on the day of missed menses. The results here suggest similar sensitivity for these two tests. The EPT and ClearBlue manual and digital test make similar >99% claims, the data presented here disputes their elevated claim.

  7. The Role of Motive Objects in Early Childhood Teacher Development Concerning Children's Digital Play and Play-Based Learning in Early Childhood Curricula

    ERIC Educational Resources Information Center

    Nuttall, Joce; Edwards, Susan; Mantilla, Ana; Grieshaber, Sue; Wood, Elizabeth

    2015-01-01

    Digital technologies are increasingly accepted as a viable aspect of early childhood curriculum. However, teacher uptake of digital technologies in early childhood education and their use with young children in play-based approaches to learning have not been strong. Traditional approaches to the problem of teacher uptake of digital technologies in…

  8. How Young Children and Their Mothers Experience Two Different Types of Toys: A Traditional Stuffed Toy versus an Animated Digital Toy

    ERIC Educational Resources Information Center

    Sung, Jihyun

    2018-01-01

    Background: Despite widespread use of digital toys, research evidence of how a digital toy's features affect children's development and the nature of parent-child interactions during play is limited. Objective: The present study aimed to examine how mother-child dyads experience a traditional stuffed toy and an animated digital toy by comparing…

  9. The role of digital data entry in participatory environmental monitoring.

    PubMed

    Brammer, Jeremy R; Brunet, Nicolas D; Burton, A Cole; Cuerrier, Alain; Danielsen, Finn; Dewan, Kanwaljeet; Herrmann, Thora Martina; Jackson, Micha V; Kennett, Rod; Larocque, Guillaume; Mulrennan, Monica; Pratihast, Arun Kumar; Saint-Arnaud, Marie; Scott, Colin; Humphries, Murray M

    2016-12-01

    Many argue that monitoring conducted exclusively by scientists is insufficient to address ongoing environmental challenges. One solution entails the use of mobile digital devices in participatory monitoring (PM) programs. But how digital data entry affects programs with varying levels of stakeholder participation, from nonscientists collecting field data to nonscientists administering every step of a monitoring program, remains unclear. We reviewed the successes, in terms of management interventions and sustainability, of 107 monitoring programs described in the literature (hereafter programs) and compared these with case studies from our PM experiences in Australia, Canada, Ethiopia, Ghana, Greenland, and Vietnam (hereafter cases). Our literature review showed that participatory programs were less likely to use digital devices, and 2 of our 3 more participatory cases were also slow to adopt digital data entry. Programs that were participatory and used digital devices were more likely to report management actions, which was consistent with cases in Ethiopia, Greenland, and Australia. Programs engaging volunteers were more frequently reported as ongoing, but those involving digital data entry were less often sustained when data collectors were volunteers. For the Vietnamese and Canadian cases, sustainability was undermined by a mismatch in stakeholder objectives. In the Ghanaian case, complex field protocols diminished monitoring sustainability. Innovative technologies attract interest, but the foundation of effective participatory adaptive monitoring depends more on collaboratively defined questions, objectives, conceptual models, and monitoring approaches. When this foundation is built through effective partnerships, digital data entry can enable the collection of more data of higher quality. Without this foundation, or when implemented ineffectively or unnecessarily, digital data entry can be an additional expense that distracts from core monitoring objectives and undermines project sustainability. The appropriate role of digital data entry in PM likely depends more on the context in which it is used and less on the technology itself. © 2016 Society for Conservation Biology.

  10. Selective recruitment of single motor units in human flexor digitorum superficialis muscle during flexion of individual fingers.

    PubMed

    Butler, T J; Kilbreath, S L; Gorman, R B; Gandevia, S C

    2005-08-15

    Flexor digitorum superficialis (FDS) is an extrinsic multi-tendoned muscle which flexes the proximal interphalangeal joints of the four fingers. It comprises four digital components, each with a tendon that inserts onto its corresponding finger. To determine the degree to which these digital components can be selectively recruited by volition, we recorded the activity of a single motor unit in one component via an intramuscular electrode while the subject isometrically flexed each of the remaining fingers, one at a time. The finger on which the unit principally acted was defined as the 'test finger' and that which flexed isometrically was the 'active' finger. Activity in 79 units was recorded. Isometric finger flexion forces of 50% maximum voluntary contraction (MVC) activated less than 50% of single units in components of FDS acting on fingers that were not voluntarily flexed. With two exceptions, the median recruitment threshold for all active-test finger combinations involving the index, middle, ring and little finger test units was between 49 and 60% MVC (60% MVC being the value assigned to those not recruited). The exceptions were flexion of the little finger while recording from ring finger units (median: 40% MVC), and vice versa (median: 2% MVC). For all active-test finger combinations, only 35/181 units were activated when the active finger flexed at less than 20% MVC, and the fingers were adjacent for 28 of these. Functionally, to recruit FDS units during grasping and lifting, relatively heavy objects were required, although systematic variation occurred with the width of the object. In conclusion, FDS components can be selectively activated by volition and this may be especially important for grasping at high forces with one or more fingers.

  11. Semi-automated extraction of longitudinal subglacial bedforms from digital terrain models - Two new methods

    NASA Astrophysics Data System (ADS)

    Jorge, Marco G.; Brennand, Tracy A.

    2017-07-01

    Relict drumlin and mega-scale glacial lineation (positive relief, longitudinal subglacial bedforms - LSBs) morphometry has been used as a proxy for paleo ice-sheet dynamics. LSB morphometric inventories have relied on manual mapping, which is slow and subjective and thus potentially difficult to reproduce. Automated methods are faster and reproducible, but previous methods for LSB semi-automated mapping have not been highly successful. Here, two new object-based methods for the semi-automated extraction of LSBs (footprints) from digital terrain models are compared in a test area in the Puget Lowland, Washington, USA. As segmentation procedures to create LSB-candidate objects, the normalized closed contour method relies on the contouring of a normalized local relief model addressing LSBs on slopes, and the landform elements mask method relies on the classification of landform elements derived from the digital terrain model. For identifying which LSB-candidate objects correspond to LSBs, both methods use the same LSB operational definition: a ruleset encapsulating expert knowledge, published morphometric data, and the morphometric range of LSBs in the study area. The normalized closed contour method was separately applied to four different local relief models, two computed in moving windows and two hydrology-based. Overall, the normalized closed contour method outperformed the landform elements mask method. The normalized closed contour method performed on a hydrological relief model from a multiple direction flow routing algorithm performed best. For an assessment of its transferability, the normalized closed contour method was evaluated on a second area, the Chautauqua drumlin field, Pennsylvania and New York, USA where it performed better than in the Puget Lowland. A broad comparison to previous methods suggests that the normalized relief closed contour method may be the most capable method to date, but more development is required.

  12. Chirped pulse digital holography for measuring the sequence of ultrafast optical wavefronts

    NASA Astrophysics Data System (ADS)

    Karasawa, Naoki

    2018-04-01

    Optical setups for measuring the sequence of ultrafast optical wavefronts using a chirped pulse as a reference wave in digital holography are proposed and analyzed. In this method, multiple ultrafast object pulses are used to probe the temporal evolution of ultrafast phenomena and they are interfered with a chirped reference wave to record a digital hologram. Wavefronts at different times can be reconstructed separately from the recorded hologram when the reference pulse can be treated as a quasi-monochromatic wave during the pulse width of each object pulse. The feasibility of this method is demonstrated by numerical simulation.

  13. Speckle noise reduction in digital holography by slightly rotating the object

    NASA Astrophysics Data System (ADS)

    Herrera-Ramirez, Jorge; Hincapie-Zuluaga, Diego Andrés; Garcia-Sucerquia, Jorge

    2016-12-01

    This work shows the realization of speckle reduction in the numerical reconstruction of digitally recorded holograms by the superposition of multiple slightly rotated digital holographic images of the object. The superposition of T uncorrelated holographic images reduces the contrast of the speckle noise of the image following the expected 1/√{T} law. The effect of the method on the borders of the resulting image is evaluated by quantifying the utilization of the dynamic range or the contrast between the white and black areas of a regular die. Experimental results validate the feasibility of the proposed method.

  14. Accurate and cost-effective MTF measurement system for lens modules of digital cameras

    NASA Astrophysics Data System (ADS)

    Chang, Gao-Wei; Liao, Chia-Cheng; Yeh, Zong-Mu

    2007-01-01

    For many years, the widening use of digital imaging products, e.g., digital cameras, has given rise to much attention in the market of consumer electronics. However, it is important to measure and enhance the imaging performance of the digital ones, compared to that of conventional cameras (with photographic films). For example, the effect of diffraction arising from the miniaturization of the optical modules tends to decrease the image resolution. As a figure of merit, modulation transfer function (MTF) has been broadly employed to estimate the image quality. Therefore, the objective of this paper is to design and implement an accurate and cost-effective MTF measurement system for the digital camera. Once the MTF of the sensor array is provided, that of the optical module can be then obtained. In this approach, a spatial light modulator (SLM) is employed to modulate the spatial frequency of light emitted from the light-source. The modulated light going through the camera under test is consecutively detected by the sensors. The corresponding images formed from the camera are acquired by a computer and then, they are processed by an algorithm for computing the MTF. Finally, through the investigation on the measurement accuracy from various methods, such as from bar-target and spread-function methods, it appears that our approach gives quite satisfactory results.

  15. Mapping Vegetation Community Types in a Highly-Disturbed Landscape: Integrating Hiearchical Object-Based Image Analysis with Digital Surface Models

    NASA Astrophysics Data System (ADS)

    Snavely, Rachel A.

    Focusing on the semi-arid and highly disturbed landscape of San Clemente Island, California, this research tests the effectiveness of incorporating a hierarchal object-based image analysis (OBIA) approach with high-spatial resolution imagery and light detection and range (LiDAR) derived canopy height surfaces for mapping vegetation communities. The study is part of a large-scale research effort conducted by researchers at San Diego State University's (SDSU) Center for Earth Systems Analysis Research (CESAR) and Soil Ecology and Restoration Group (SERG), to develop an updated vegetation community map which will support both conservation and management decisions on Naval Auxiliary Landing Field (NALF) San Clemente Island. Trimble's eCognition Developer software was used to develop and generate vegetation community maps for two study sites, with and without vegetation height data as input. Overall and class-specific accuracies were calculated and compared across the two classifications. The highest overall accuracy (approximately 80%) was observed with the classification integrating airborne visible and near infrared imagery having very high spatial resolution with a LiDAR derived canopy height model. Accuracies for individual vegetation classes differed between both classification methods, but were highest when incorporating the LiDAR digital surface data. The addition of a canopy height model, however, yielded little difference in classification accuracies for areas of very dense shrub cover. Overall, the results show the utility of the OBIA approach for mapping vegetation with high spatial resolution imagery, and emphasizes the advantage of both multi-scale analysis and digital surface data for accuracy characterizing highly disturbed landscapes. The integrated imagery and digital canopy height model approach presented both advantages and limitations, which have to be considered prior to its operational use in mapping vegetation communities.

  16. Development of eHOME, a Mobile Instrument for Reporting, Monitoring, and Consulting Drug-Related Problems in Home Care: Human-Centered Design Study

    PubMed Central

    Sino, Carolina Geertruida Maria; Heerdink, Eibert Rob; Schuurmans, Marieke Joanna

    2018-01-01

    Background Home care patients often use many medications and are prone to drug-related problems (DRPs). For the management of problems related to drug use, home care could add to the multidisciplinary expertise of general practitioners (GPs) and pharmacists. The home care observation of medication-related problems by home care employees (HOME)-instrument is paper-based and assists home care workers in reporting potential DRPs. To facilitate the multiprofessional consultation, a digital report of DRPs from the HOME-instrument and digital monitoring and consulting of DRPs between home care and general practices and pharmacies is desired. Objective The objective of this study was to develop an electronic HOME system (eHOME), a mobile version of the HOME-instrument that includes a monitoring and a consulting system for primary care. Methods The development phase of the Medical Research Council (MRC) framework was followed in which an iterative human-centered design (HCD) approach was applied. The approach involved a Delphi round for the context of use and user requirements analysis of the digital HOME-instrument and the monitoring and consulting system followed by 2 series of pilots for testing the usability and redesign. Results By using an iterative design approach and by involving home care workers, GPs, and pharmacists throughout the process as informants, design partners, and testers, important aspects that were crucial for system realization and user acceptance were revealed. Through the report webpage interface, which includes the adjusted content of the HOME-instrument and added home care practice–based problems, home care workers can digitally report observed DRPs. Furthermore, it was found that the monitoring and consulting webpage interfaces enable digital consultation between home care and general practices and pharmacies. The webpages were considered convenient, clear, easy, and usable. Conclusions By employing an HCD approach, the eHOME-instrument was found to be an easy-to-use system. The systematic approach promises a valuable contribution for the future development of digital mobile systems of paper-based tools. PMID:29514771

  17. Flight test of a full authority Digital Electronic Engine Control system in an F-15 aircraft

    NASA Technical Reports Server (NTRS)

    Barrett, W. J.; Rembold, J. P.; Burcham, F. W.; Myers, L.

    1981-01-01

    The Digital Electronic Engine Control (DEEC) system considered is a relatively low cost digital full authority control system containing selectively redundant components and fault detection logic with capability for accommodating faults to various levels of operational capability. The DEEC digital control system is built around a 16-bit, 1.2 microsecond cycle time, CMOS microprocessor, microcomputer system with approximately 14 K of available memory. Attention is given to the control mode, component bench testing, closed loop bench testing, a failure mode and effects analysis, sea-level engine testing, simulated altitude engine testing, flight testing, the data system, cockpit, and real time display.

  18. Development of a 3D printer using scanning projection stereolithography

    PubMed Central

    Lee, Michael P.; Cooper, Geoffrey J. T.; Hinkley, Trevor; Gibson, Graham M.; Padgett, Miles J.; Cronin, Leroy

    2015-01-01

    We have developed a system for the rapid fabrication of low cost 3D devices and systems in the laboratory with micro-scale features yet cm-scale objects. Our system is inspired by maskless lithography, where a digital micromirror device (DMD) is used to project patterns with resolution up to 10 µm onto a layer of photoresist. Large area objects can be fabricated by stitching projected images over a 5cm2 area. The addition of a z-stage allows multiple layers to be stacked to create 3D objects, removing the need for any developing or etching steps but at the same time leading to true 3D devices which are robust, configurable and scalable. We demonstrate the applications of the system by printing a range of micro-scale objects as well as a fully functioning microfluidic droplet device and test its integrity by pumping dye through the channels. PMID:25906401

  19. Compression evaluation of surgery video recordings retaining diagnostic credibility (compression evaluation of surgery video)

    NASA Astrophysics Data System (ADS)

    Duplaga, M.; Leszczuk, M. I.; Papir, Z.; Przelaskowski, A.

    2008-12-01

    Wider dissemination of medical digital video libraries is affected by two correlated factors, resource effective content compression that directly influences its diagnostic credibility. It has been proved that it is possible to meet these contradictory requirements halfway for long-lasting and low motion surgery recordings at compression ratios close to 100 (bronchoscopic procedures were a case study investigated). As the main supporting assumption, it has been accepted that the content can be compressed as far as clinicians are not able to sense a loss of video diagnostic fidelity (a visually lossless compression). Different market codecs were inspected by means of the combined subjective and objective tests toward their usability in medical video libraries. Subjective tests involved a panel of clinicians who had to classify compressed bronchoscopic video content according to its quality under the bubble sort algorithm. For objective tests, two metrics (hybrid vector measure and hosaka Plots) were calculated frame by frame and averaged over a whole sequence.

  20. Application of Digital Radiography to Weld Inspection for the Space Shuttle External Fuel Tank

    NASA Technical Reports Server (NTRS)

    Ussery, Warren

    2009-01-01

    This slide presentation reviews NASA's use of digital radiography to inspect the welds of the external tanks used to hold the cryogenic fuels for the Space Shuttle Main Engines. NASA has had a goal of replacing a significant portion of film used to inspect the welds, with digital radiography. The presentation reviews the objectives for converting to a digital system from film, the characteristics of the digital system, the Probability of detection study, the qualification and implementation of the system.

  1. Digital stethoscopes compared to standard auscultation for detecting abnormal paediatric breath sounds.

    PubMed

    Kevat, Ajay C; Kalirajah, Anaath; Roseby, Robert

    2017-07-01

    Our study aimed to objectively describe the audiological characteristics of wheeze and crackles in children by using digital stethoscope (DS) auscultation, as well as assess concordance between standard auscultation and two different DS devices in their ability to detect pathological breath sounds. Twenty children were auscultated by a paediatric consultant doctor and digitally recorded using the Littman™ 3200 Digital Electronic Stethoscope and a Clinicloud™ DS with smart device. Using spectrographic analysis, we found those with clinically described wheeze had prominent periodic waveform segments spanning expiration for a period of 0.03-1.2 s at frequencies of 100-1050 Hz, and occasionally spanning shorter inspiratory segments; paediatric crackles were brief discontinuous sounds with a distinguishing waveform. There was moderate concordance with respect to wheeze detection between digital and standard binaural stethoscopes, and 100% concordance for crackle detection. Importantly, DS devices were more sensitive than clinician auscultation in detecting wheeze in our study. Objective definition of audio characteristics of abnormal paediatric breath sounds was achieved using DS technology. We demonstrated superiority of our DS method compared to traditional auscultation for detection of wheeze. What is Known: • The audiological characteristics of abnormal breath sounds have been well-described in adult populations but not in children. • Inter-observer agreement for detection of pathological breath sounds using standard auscultation has been shown to be poor, but the clinical value of now easily available digital stethoscopes has not been sufficiently examined. What is New: • Digital stethoscopes can objectively define the nature of pathological breath sounds such as wheeze and crackles in children. • Paediatric wheeze was better detected by digital stethoscopes than by standard auscultation performed by an expert paediatric clinician.

  2. Large object investigation by digital holography with effective spectrum multiplexing under single-exposure approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liu, Ning, E-mail: coolboy006@sohu.com; Zhang, Yingying; Xie, Jun

    2014-10-13

    We present a method to investigate large object by digital holography with effective spectrum multiplexing under single-exposure approach. This method splits the original reference beam and redirects one of its branches as a second object beam. Through the modified Mach-Zehnder interferometer, the two object beams can illuminate different parts of the large object and create a spectrum multiplexed hologram onto the focal plane array of the charge-coupled device/complementary metal oxide semiconductor camera. After correct spectrum extraction and image reconstruction, the large object can be fully observed within only one single snap-shot. The flexibility and great performance make our method amore » very attractive and promising technique for large object investigation under common 632.8 nm illumination.« less

  3. The paced auditory serial addition test for working memory assessment: Psychometric properties

    PubMed Central

    Nikravesh, Maryam; Jafari, Zahra; Mehrpour, Masoud; Kazemi, Roozbeh; Amiri Shavaki, Younes; Hossienifar, Shamim; Azizi, Mohamad Parsa

    2017-01-01

    Background: The paced auditory serial addition test (PASAT) was primarily developed to assess the effects of traumatic brain injury on cognitive functioning. Working memory (WM) is one of the most important aspects of cognitive function, and WM impairment is one of the clinically remarkable signs of aphasia. To develop the Persian version of PASAT, an initial version was used in individuals with aphasia (IWA). Methods: In this study, 25 individuals with aphasia (29-60 years) and 85 controls (18-60 years) were included. PASAT was presented in the form of recorded 61 single-digit numbers (1 to 9). The participants repeatedly added the 2 recent digits. The psychometric properties of PASAT including convergent validity (using the digit memory span tasks), divergent validity (using results in the control group and IWA group), and face validity were investigated. Test-retest reliability was considered as well. Results: The relationship between the PASAT and digit memory span tests was moderate to strong in the control group (forward digit memory span test: r= 0.52, p< 0.0001; backward digit memory span test: r = 0.48, p< 0.0001). A strong relationship was found in IWA (forward digit memory span test: r= 0.72, p< 0.0001; backward digit memory span test: r= 0.53, p= 0.006). Also, strong testretest reliability (intraclass correlation= 0.95, p< 0.0001) was observed. Conclusion: According to our results, the PASAT is a valid and reliable test to assess working memory, particularly in IWA. It could be used as a feasible tool for clinical and research applications. PMID:29445690

  4. Mutation Testing for Effective Verification of Digital Components of Physical Systems

    NASA Astrophysics Data System (ADS)

    Kushik, N. G.; Evtushenko, N. V.; Torgaev, S. N.

    2015-12-01

    Digital components of modern physical systems are often designed applying circuitry solutions based on the field programmable gate array technology (FPGA). Such (embedded) digital components should be carefully tested. In this paper, an approach for the verification of digital physical system components based on mutation testing is proposed. The reference description of the behavior of a digital component in the hardware description language (HDL) is mutated by introducing into it the most probable errors and, unlike mutants in high-level programming languages, the corresponding test case is effectively derived based on a comparison of special scalable representations of the specification and the constructed mutant using various logic synthesis and verification systems.

  5. TU-AB-207-00: Digital Tomosynthesis

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    NONE

    2015-06-15

    Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact,more » the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.« less

  6. Pipeline for effective denoising of digital mammography and digital breast tomosynthesis

    NASA Astrophysics Data System (ADS)

    Borges, Lucas R.; Bakic, Predrag R.; Foi, Alessandro; Maidment, Andrew D. A.; Vieira, Marcelo A. C.

    2017-03-01

    Denoising can be used as a tool to enhance image quality and enforce low radiation doses in X-ray medical imaging. The effectiveness of denoising techniques relies on the validity of the underlying noise model. In full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT), calibration steps like the detector offset and flat-fielding can affect some assumptions made by most denoising techniques. Furthermore, quantum noise found in X-ray images is signal-dependent and can only be treated by specific filters. In this work we propose a pipeline for FFDM and DBT image denoising that considers the calibration steps and simplifies the modeling of the noise statistics through variance-stabilizing transformations (VST). The performance of a state-of-the-art denoising method was tested with and without the proposed pipeline. To evaluate the method, objective metrics such as the normalized root mean square error (N-RMSE), noise power spectrum, modulation transfer function (MTF) and the frequency signal-to-noise ratio (SNR) were analyzed. Preliminary tests show that the pipeline improves denoising. When the pipeline is not used, bright pixels of the denoised image are under-filtered and dark pixels are over-smoothed due to the assumption of a signal-independent Gaussian model. The pipeline improved denoising up to 20% in terms of spatial N-RMSE and up to 15% in terms of frequency SNR. Besides improving the denoising, the pipeline does not increase signal smoothing significantly, as shown by the MTF. Thus, the proposed pipeline can be used with state-of-the-art denoising techniques to improve the quality of DBT and FFDM images.

  7. Digital Imaging

    NASA Technical Reports Server (NTRS)

    1986-01-01

    Digital Imaging is the computer processed numerical representation of physical images. Enhancement of images results in easier interpretation. Quantitative digital image analysis by Perceptive Scientific Instruments, locates objects within an image and measures them to extract quantitative information. Applications are CAT scanners, radiography, microscopy in medicine as well as various industrial and manufacturing uses. The PSICOM 327 performs all digital image analysis functions. It is based on Jet Propulsion Laboratory technology, is accurate and cost efficient.

  8. Review of digital holography reconstruction methods

    NASA Astrophysics Data System (ADS)

    Dovhaliuk, Rostyslav Yu.

    2018-01-01

    Development of digital holography opened new ways of both transparent and opaque objects non-destructive study. In this paper, a digital hologram reconstruction process is investigated. The advantages and limitations of common wave propagation methods are discussed. The details of a software implementation of a digital hologram reconstruction methods are presented. Finally, the performance of each wave propagation method is evaluated, and recommendations about possible use cases for each of them are given.

  9. Strain measurement of objects subjected to aerodynamic heating using digital image correlation: experimental design and preliminary results.

    PubMed

    Pan, Bing; Jiang, Tianyun; Wu, Dafang

    2014-11-01

    In thermomechanical testing of hypersonic materials and structures, direct observation and quantitative strain measurement of the front surface of a test specimen directly exposed to severe aerodynamic heating has been considered as a very challenging task. In this work, a novel quartz infrared heating device with an observation window is designed to reproduce the transient thermal environment experienced by hypersonic vehicles. The specially designed experimental system allows the capture of test article's surface images at various temperatures using an optical system outfitted with a bandpass filter. The captured images are post-processed by digital image correlation to extract full-field thermal deformation. To verify the viability and accuracy of the established system, thermal strains of a chromiumnickel austenite stainless steel sample heated from room temperature up to 600 °C were determined. The preliminary results indicate that the air disturbance between the camera and the specimen due to heat haze induces apparent distortions in the recorded images and large errors in the measured strains, but the average values of the measured strains are accurate enough. Limitations and further improvements of the proposed technique are discussed.

  10. Digital Image Correlation for Performance Monitoring.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Palaviccini, Miguel; Turner, Daniel Z.; Herzberg, Michael

    2016-02-01

    Evaluating the health of a mechanism requires more than just a binary evaluation of whether an operation was completed. It requires analyzing more comprehensive, full-field data. Health monitoring is a process of nondestructively identifying characteristics that indicate the fitness of an engineered component. In order to monitor unit health in a production setting, an automated test system must be created to capture the motion of mechanism parts in a real-time and non-intrusive manner. One way to accomplish this is by using high-speed video (HSV) and Digital Image Correlation (DIC). In this approach, individual frames of the video are analyzed tomore » track the motion of mechanism components. The derived performance metrics allow for state-of-health monitoring and improved fidelity of mechanism modeling. The results are in-situ state-of-health identification and performance prediction. This paper introduces basic concepts of this test method, and discusses two main themes: the use of laser marking to add fiducial patterns to mechanism components, and new software developed to track objects with complex shapes, even as they move behind obstructions. Finally, the implementation of these tests into an automated tester is discussed.« less

  11. Neuropsychological Assessment of Adult Patients with Shunted Hydrocephalus

    PubMed Central

    Bakar, Emel Erdogan

    2010-01-01

    Objective This study is planned to determine the neurocognitive difficulties of hydrocephalic adults. Methods The research group contained healthy adults (control group, n : 15), and hydrocephalic adults (n : 15). Hydrocephalic group consisted of patients with idiopathic aquaduct stenosis and post-meningitis hydrocephalus. All patients were followed with shunted hydrocephalus and not gone to shunt revision during last two years. They were chosen from either asymptomatic or had only minor symptoms without motor and sensorineural deficit. A neuropsychological test battery (Raven Standart Progressive Matrices, Bender-Gestalt Test, Cancellation Test, Clock Drawing Test, Facial Recognition Test, Line Orientation Test, Serial Digit Learning Test, Stroop Color Word Interference Test-TBAG Form, Verbal Fluency Test, Verbal Fluency Test, Visual-Aural Digit Span Test-B) was applied to all groups. Results Neuropsychological assessment of hydrocephalic patients demonstrated that they had poor performance on visual, semantic and working memory, visuoconstructive and frontal functions, reading, attention, motor coordination and executive function of parietal lobe which related with complex and perseverative behaviour. Eventually, these patients had significant impairment on the neurocognitive functions of their frontal, parietal and temporal lobes. On the other hand, the statistical analyses performed on demographic data showed that the aetiology of the hydrocephalus, age, sex and localization of the shunt (frontal or posterior parietal) did not affect the test results. Conclusion This prospective study showed that adult patients with hydrocephalus have serious neuropsychological problems which might be directly caused by the hydrocephalus; and these problems may cause serious adaptive difficulties in their social, cultural, behavioral and academic life. PMID:20379471

  12. The ERESE Project: Interfacing with the ERDA Digital Archive and ERR Reference Database in EarthRef.org

    NASA Astrophysics Data System (ADS)

    Koppers, A. A.; Staudigel, H.; Mills, H.; Keller, M.; Wallace, A.; Bachman, N.; Helly, J.; Helly, M.; Miller, S. P.; Massell Symons, C.

    2004-12-01

    To bridge the gap between Earth science teachers, librarians, scientists and data archive managers, we have started the ERESE project that will create, archive and make available "Enduring Resources in Earth Science Education" through information technology (IT) portals. In the first phase of this National Science Digital Library (NSDL) project, we are focusing on the development of these ERESE resources for middle and high school teachers to be used in lesson plans with "plate tectonics" and "magnetics" as their main theme. In this presentation, we will show how these new ERESE resources are being generated, how they can be uploaded via online web wizards, how they are archived, how we make them available via the EarthRef.org Digital Archive (ERDA) and Reference Database (ERR), and how they relate to the SIOExplorer database containing data objects for all seagoing cruises carried out by the Scripps Institution of Oceanography. The EarthRef.org web resource uses the vision of a "general description" of the Earth as a geological system to provide an IT infrastructure for the Earth sciences. This emphasizes the marriage of the "scientific process" (and its results) with an educational cyber-infrastructure for teaching Earth sciences, on any level, from middle school to college and graduate levels. Eight different databases reside under EarthRef.org from which ERDA holds any digital object that has been uploaded by other scientists, teachers and students for free, while the ERR holds more than 80,000 publications. For more than 1,500 of these publications, this latter database makes available for downloading JPG/PDF images of the abstracts, data tables, methods and appendices, together with their digitized contents in Microsoft Word and Excel format. Both holdings are being used to store the ERESE objects that are being generated by a group of undergraduate students majoring in Environmental Systems (ESYS) program at the UCSD with an emphasis on the Earth Sciences. These students perform library and internet research in order to design and generate these "Enduring Resources in Earth Science Education" that they test by closely interacting with the research faculty at the Scripps Institution of Oceanography. Typical ERESE resources can be diagrams, model cartoons, maps, data sets for analyses, and glossary items and essays to explain certain Earth Science concepts and are ready to be used in the classroom.

  13. Stochastic digital holography for visualizing inside strongly refracting transparent objects.

    PubMed

    Desse, Jean-Michel; Picart, Pascal

    2015-01-01

    This paper presents a digital holographic method to visualize and measure refractive index variations, convection currents, or thermal gradients, occurring inside a transparent and refracting object. The proof of principle is provided through the visualization of refractive index variation inside a lighting bulb. Comparison with transmission and reflection holography is also provided. A very good agreement is obtained, thus validating the proposed approach.

  14. Field Birding and Digital Objects: Immaterial Technologies and Their Implications for One Practice of Coming to Know the More-than-Human

    ERIC Educational Resources Information Center

    Watson, Gavan Peter Longley

    2011-01-01

    This paper focuses on the implications of two emerging digital technologies on the act of field birding, and the implications of these objects for thinking about wild birds. While the adoption of new immaterial technologies promises to improve the ease with which birding is practiced, their use leads to new ethical considerations. Using the…

  15. Precision pointing and control of flexible spacecraft

    NASA Technical Reports Server (NTRS)

    Bantell, M. H., Jr.

    1987-01-01

    The problem and long term objectives for the precision pointing and control of flexible spacecraft are given. The four basic objectives are stated in terms of two principle tasks. Under Task 1, robust low order controllers, improved structural modeling methods for control applications and identification methods for structural dynamics are being developed. Under Task 2, a lab test experiment for verification of control laws and system identification algorithms is being developed. For Task 1, work has focused on robust low order controller design and some initial considerations for structural modeling in control applications. For Task 2, work has focused on experiment design and fabrication, along with sensor selection and initial digital controller implementation. Conclusions are given.

  16. Feasibility of automated dropsize distributions from holographic data using digital image processing techniques. [particle diameter measurement technique

    NASA Technical Reports Server (NTRS)

    Feinstein, S. P.; Girard, M. A.

    1979-01-01

    An automated technique for measuring particle diameters and their spatial coordinates from holographic reconstructions is being developed. Preliminary tests on actual cold-flow holograms of impinging jets indicate that a suitable discriminant algorithm consists of a Fourier-Gaussian noise filter and a contour thresholding technique. This process identifies circular as well as noncircular objects. The desired objects (in this case, circular or possibly ellipsoidal) are then selected automatically from the above set and stored with their parametric representations. From this data, dropsize distributions as a function of spatial coordinates can be generated and combustion effects due to hardware and/or physical variables studied.

  17. An object-based approach for tree species extraction from digital orthophoto maps

    NASA Astrophysics Data System (ADS)

    Jamil, Akhtar; Bayram, Bulent

    2018-05-01

    Tree segmentation is an active and ongoing research area in the field of photogrammetry and remote sensing. It is more challenging due to both intra-class and inter-class similarities among various tree species. In this study, we exploited various statistical features for extraction of hazelnut trees from 1 : 5000 scaled digital orthophoto maps. Initially, the non-vegetation areas were eliminated using traditional normalized difference vegetation index (NDVI) followed by application of mean shift segmentation for transforming the pixels into meaningful homogeneous objects. In order to eliminate false positives, morphological opening and closing was employed on candidate objects. A number of heuristics were also derived to eliminate unwanted effects such as shadow and bounding box aspect ratios, before passing them into the classification stage. Finally, a knowledge based decision tree was constructed to distinguish the hazelnut trees from rest of objects which include manmade objects and other type of vegetation. We evaluated the proposed methodology on 10 sample orthophoto maps obtained from Giresun province in Turkey. The manually digitized hazelnut tree boundaries were taken as reference data for accuracy assessment. Both manually digitized and segmented tree borders were converted into binary images and the differences were calculated. According to the obtained results, the proposed methodology obtained an overall accuracy of more than 85 % for all sample images.

  18. Optimization of digitization procedures in cultural heritage preservation

    NASA Astrophysics Data System (ADS)

    Martínez, Bea; Mitjà, Carles; Escofet, Jaume

    2013-11-01

    The digitization of both volumetric and flat objects is the nowadays-preferred method in order to preserve cultural heritage items. High quality digital files obtained from photographic plates, films and prints, paintings, drawings, gravures, fabrics and sculptures, allows not only for a wider diffusion and on line transmission, but also for the preservation of the original items from future handling. Early digitization procedures used scanners for flat opaque or translucent objects and camera only for volumetric or flat highly texturized materials. The technical obsolescence of the high-end scanners and the improvement achieved by professional cameras has result in a wide use of cameras with digital back to digitize any kind of cultural heritage item. Since the lens, the digital back, the software controlling the camera and the digital image processing provide a wide range of possibilities, there is necessary to standardize the methods used in the reproduction work leading to preserve as high as possible the original item properties. This work presents an overview about methods used for camera system characterization, as well as the best procedures in order to identify and counteract the effect of the lens residual aberrations, sensor aliasing, image illumination, color management and image optimization by means of parametric image processing. As a corollary, the work shows some examples of reproduction workflow applied to the digitization of valuable art pieces and glass plate photographic black and white negatives.

  19. A building extraction approach for Airborne Laser Scanner data utilizing the Object Based Image Analysis paradigm

    NASA Astrophysics Data System (ADS)

    Tomljenovic, Ivan; Tiede, Dirk; Blaschke, Thomas

    2016-10-01

    In the past two decades Object-Based Image Analysis (OBIA) established itself as an efficient approach for the classification and extraction of information from remote sensing imagery and, increasingly, from non-image based sources such as Airborne Laser Scanner (ALS) point clouds. ALS data is represented in the form of a point cloud with recorded multiple returns and intensities. In our work, we combined OBIA with ALS point cloud data in order to identify and extract buildings as 2D polygons representing roof outlines in a top down mapping approach. We performed rasterization of the ALS data into a height raster for the purpose of the generation of a Digital Surface Model (DSM) and a derived Digital Elevation Model (DEM). Further objects were generated in conjunction with point statistics from the linked point cloud. With the use of class modelling methods, we generated the final target class of objects representing buildings. The approach was developed for a test area in Biberach an der Riß (Germany). In order to point out the possibilities of the adaptation-free transferability to another data set, the algorithm has been applied ;as is; to the ISPRS Benchmarking data set of Toronto (Canada). The obtained results show high accuracies for the initial study area (thematic accuracies of around 98%, geometric accuracy of above 80%). The very high performance within the ISPRS Benchmark without any modification of the algorithm and without any adaptation of parameters is particularly noteworthy.

  20. Radiopacity evaluation of contemporary resin composites by digitization of images

    PubMed Central

    Ermis, R. Banu; Yildirim, Derya; Yildiz, Gul; Gormez, Ozlem

    2014-01-01

    Objective: The aim of this study was to evaluate the radiopacity of different composite resins and compare the values to those of human enamel and dentine. Materials and Methods: Five specimens of each material with thicknesses of 2 mm were prepared and radiographed alongside aluminum step wedge and human enamel and dentin. Three occlusal radiographs for each material were taken and digitized using a desktop scanner. Mean gray values of the test materials were measured using Image J software. Then a conversion was performed according to establish the radiopacity of the test materials, in millimeters of equivalent Al. Data were analyzed using one-way analysis of variance and Duncan multiple range tests (P < 0.05). Results: The radiopacity values varied among the restorative materials (P < 0.05). The radiopacity values of the materials tested were, in decreasing order: Enamel Plus HRI > Z250 > Filtek Ultimate ≥ Z550 > Nexcomp ≥ Nanoceram Bright > enamel ≥ Estelite Sigma Quick > Clearfil Majesty Esthetic ≥ Reflexions XLS ≥ Aelite LS Posterior ≥ dentin ≥ 2 mm Al. Conclusion: All resin composite materials investigated in this study presented different radiopacity values. However, all materials had radiopacity values greater than dentin and had sufficient radiopacity to meet International Organization for Standardization 4049 standard. PMID:25202214

  1. Digital image analysis of testicular and prostatic ultrasonographic echogencity and heterogeneity in dogs and the relation to semen quality.

    PubMed

    Moxon, Rachel; Bright, Lucy; Pritchard, Beth; Bowen, I Mark; de Souza, Mírley Barbosa; da Silva, Lúcia Daniel Machado; England, Gary C W

    2015-09-01

    A semi-automated ultrasonographic method was developed to measure echogenicity and heterogeneity of the testes and prostate gland and relationships of these measures with semen quality were assessed in 43 fertile dogs. The relationship between animal age and body weight upon the volume of the testes, epididymal tail volume and prostate volume were also established. Mean testicular echogenicity was negatively correlated with the percentage of morphologically normal live spermatozoa (more echogenic testes were associated with fewer normal sperm) but not with any other semen quality measure. Mean testicular heterogeneity was positively correlated with the total spermatozoal output (more heterogenous testes, being those with anechoic parenchyma and prominent echogenic stippling, were associated with greater sperm output) but not with any other semen quality measure. There was no relationship between either mean prostatic echogenicity or mean prostatic heterogeneity and any semen quality measure. There was no relationship between age and any testicular or prostatic parameter; however bodyweight was significantly correlated with total testicular volume, total epididymal tail volume and total prostatic volume. Testicular and prostatic ultrasonographic echogenicity and heterogeneity can be objectively assessed using digital image analysis and testicular echogenicity and heterogeneity may be useful adjunct measurements in a breeding soundness examination. Copyright © 2015 Elsevier B.V. All rights reserved.

  2. Agriscience Teachers' Implementation of Digital Game-Based Learning in an Introductory Animal Science Course

    ERIC Educational Resources Information Center

    Webb, Angela W.; Bunch, J. C.; Wallace, Maria F.

    2015-01-01

    In today's technological age, visions for technology integration in the classroom continue to be explored and examined. Digital game-based learning is one way to purposefully integrate technology while maintaining a focus on learning objectives. This case study sought to understand agriscience teachers' experiences implementing digital game-based…

  3. Through the Teacher's Eyes: Unpacking the TPACK of Digital Fabrication Integration in Middle School Language Arts

    ERIC Educational Resources Information Center

    Smith, Shaunna

    2013-01-01

    Digital fabrication consists of manufacturing design technology that is used to facilitate the creation of physical objects. Existing research suggests digital fabrication technology can inspire student creativity and innovation in mathematics and science. However, there is a lack of research that informs teacher education by identifying practical…

  4. Software Graphical User Interface For Analysis Of Images

    NASA Technical Reports Server (NTRS)

    Leonard, Desiree M.; Nolf, Scott R.; Avis, Elizabeth L.; Stacy, Kathryn

    1992-01-01

    CAMTOOL software provides graphical interface between Sun Microsystems workstation and Eikonix Model 1412 digitizing camera system. Camera scans and digitizes images, halftones, reflectives, transmissives, rigid or flexible flat material, or three-dimensional objects. Users digitize images and select from three destinations: work-station display screen, magnetic-tape drive, or hard disk. Written in C.

  5. Small Wonders Close Encounters

    ERIC Educational Resources Information Center

    Kniseley, MacGregor; Capraro, Karen

    2013-01-01

    This article introduces students to the world of digital microscopy. Looking at small objects through a digital microscope is like traveling through a foreign country for the first time. The experience is new, engaging, and exciting. A handheld digital microscope is an essential tool in a 21st century teacher's toolkit and the perfect tool to…

  6. Terrestrial scanning or digital images in inventory of monumental objects? - case study

    NASA Astrophysics Data System (ADS)

    Markiewicz, J. S.; Zawieska, D.

    2014-06-01

    Cultural heritage is the evidence of the past; monumental objects create the important part of the cultural heritage. Selection of a method to be applied depends on many factors, which include: the objectives of inventory, the object's volume, sumptuousness of architectural design, accessibility to the object, required terms and accuracy of works. The paper presents research and experimental works, which have been performed in the course of development of architectural documentation of elements of the external facades and interiors of the Wilanów Palace Museum in Warszawa. Point clouds, acquired from terrestrial laser scanning (Z+F 5003h) and digital images taken with Nikon D3X and Hasselblad H4D cameras were used. Advantages and disadvantages of utilisation of these technologies of measurements have been analysed with consideration of the influence of the structure and reflectance of investigated monumental surfaces on the quality of generation of photogrammetric products. The geometric quality of surfaces obtained from terrestrial laser scanning data and from point clouds resulting from digital images, have been compared.

  7. AMPA experimental communications systems

    NASA Technical Reports Server (NTRS)

    Beckerman, D.; Fass, S.; Keon, T.; Sielman, P.

    1982-01-01

    The program was conducted to demonstrate the satellite communication advantages of Adaptive Phased Array Technology. A laboratory based experiment was designed and implemented to demonstrate a low earth orbit satellite communications system. Using a 32 element, L-band phased array augmented with 4 sets of weights (2 for reception and 2 for transmission) a high speed digital processing system and operating against multiple user terminals and interferers, the AMPA system demonstrated: communications with austere user terminals, frequency reuse, communications in the face of interference, and geolocation. The program and experiment objectives are described, the system hardware and software/firmware are defined, and the test performed and the resultant test data are presented.

  8. STS-48 MS Brown on OV-103's aft flight deck poses for ESC photo

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-48 Mission Specialist (MS) Mark N. Brown looks away from the portable laptop computer screen to pose for an Electronic Still Camera (ESC) photo on the aft flight deck of the earth-orbiting Discovery, Orbiter Vehicle (OV) 103. Brown was working at the payload station before the interruption. Crewmembers were testing the ESC as part of Development Test Objective (DTO) 648, Electronic Still Photography. The digital image was stored on a removable hard disk or small optical disk, and could be converted to a format suitable for downlink transmission. The ESC is making its initial appearance on this Space Shuttle mission.

  9. STS-48 Commander Creighton on OV-103's aft flight deck poses for ESC photo

    NASA Technical Reports Server (NTRS)

    1991-01-01

    STS-48 Commander John O. Creighton, positioned under overhead window W8, interrupts an out-the-window observation to display a pleasant countenance for an electronic still camera (ESC) photo on the aft flight deck of the earth-orbiting Discovery, Orbiter Vehicle (OV) 103. Crewmembers were testing the ESC as part of Development Test Objective (DTO) 648, Electronic Still Photography. The digital image was stored on a removable hard disk or small optical disk, and could be converted to a format suitable for downlink transmission. The ESC is making its initial appearance on this Space Shuttle mission.

  10. Short communication: Efficacy of copper sulfate hoof baths against digital dermatitis--Where is the evidence?

    PubMed

    Thomsen, Peter T

    2015-04-01

    Digital dermatitis is a major problem in modern dairy production because of decreased animal welfare and financial losses. Individual cow treatments are often seen as too time consuming by farmers, and walk-through hoof baths have therefore been used extensively to control digital dermatitis. For decades, copper sulfate hoof baths have been used to treat and prevent digital dermatitis. Copper sulfate has been referred to as the industry gold standard when it comes to hoof-bath chemicals. In several scientific studies testing the efficacy of other hoof-care products, copper sulfate has been used as a positive control, thereby indicating that copper sulfate has a known positive effect. However, this may not be the case. A dilemma may exist between (1) copper sulfate generally being perceived as being effective against digital dermatitis and (2) a possible lack of well-documented scientific evidence of this effect. The objective of this study was to evaluate the existing scientific literature to determine whether the efficacy of copper sulfate used in hoof baths against digital dermatitis has in fact been demonstrated scientifically. A systematic literature search identified 7 peer-reviewed journal articles describing the efficacy of copper sulfate in hoof baths as treatment or prevention of bovine digital dermatitis. Only 2 of the 7 studies compared copper sulfate to a negative control; most studies were relatively small, and often no clear positive effect of copper sulfate was demonstrated. In conclusion, the frequent claim that copper sulfate is widely reported to be effective is supported by little scientific evidence. Well-designed clinical trials evaluating the effect of copper sulfate against digital dermatitis compared with a negative control are needed. Until such studies have been made, the efficacy of copper sulfate in hoof baths against digital dermatitis remains largely unproven. Copyright © 2015 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  11. Manipulating Digital Holograms to Modify Phase of Reconstructed Wavefronts

    NASA Astrophysics Data System (ADS)

    Ferraro, Pietro; Paturzo, Melania; Memmolo, Pasquale; Finizio, Andrea

    2010-04-01

    We show that through an adaptive deformation of digital holograms it is possible to manage the depth of focus in the numerical reconstruction. Deformation is applied to the original hologram with the aim to put simultaneously in-focus, and in one reconstructed image plane, different objects lying at different distance from the hologram plane (i.e. CCD sensor), but in the same field of view. In the same way it is possible to extend the depth of field for 3D object having a tilted object whole in-focus.

  12. AGARD Flight Test Instrumentation Series. Volume 19. Digital Signal Conditioning for Flight Test. (Le Traitement du Signal Numerique pour les Essais n Vol)

    DTIC Science & Technology

    1991-06-01

    intensive systems, including the use of onboard digital computers. Topics include: measurements that are digital in origin, sampling, encoding, transmitting...Individuals charged with designing aircraft measuring systems to become better acquainted with new solutions to their requirements. This volume Is...concerned with aircraft measuring systems as related to flight test and flight research. Measure - ments that are digital in origin or that must be

  13. Digital Divide Measurement in Lembata Regency Using SIBIS

    NASA Astrophysics Data System (ADS)

    Gabriel, Cecilia Dai Payon Binti; Setyohadi, Djoko Budiyanto; Suyoto

    2018-02-01

    Along with technological development in Indonesia, digital divide occurs in various regions, which were behind in terms of information on how to use, access and utilize ICT in collecting information from internet. One of the regions is Lembata Regency in East Nusa Tenggara, where digital divide among the people should be measured. The purpose of this study was to determine the level of digital divide among the people of Lembata Regency. To determine the level of digital divide, we used SIBIS GPS (General Population Survey) method, which consisted of several indicators or aspect, i.e. internet usage behavior, internet utilization, and e-government. We also performed two tests, i.e. validity test and reliability test to obtain value of index of digital divide measurement among the people of Lembata Regency. The results of validity test which is processed using SPSS program are categorized valid for each variable indicator and the reliability test results show reliable status. According to the test results on digital discrepancy in Lembata people, the internet usage attitude indicator is categorized low which is 63.1%, the internet usage function indicator is categorized low which is 64%, and the digital discrepancy of e-government indicator is categorized medium which is 40.4%. Therefore, the result of this study because consideration for the government of Lembata Regency in improving ICT services in e-government and in distributing ICT access and ability equally to the people.

  14. Input-output characterization of an ultrasonic testing system by digital signal analysis

    NASA Technical Reports Server (NTRS)

    Williams, J. H., Jr.; Lee, S. S.; Karagulle, H.

    1986-01-01

    Ultrasonic test system input-output characteristics were investigated by directly coupling the transmitting and receiving transducers face to face without a test specimen. Some of the fundamentals of digital signal processing were summarized. Input and output signals were digitized by using a digital oscilloscope, and the digitized data were processed in a microcomputer by using digital signal-processing techniques. The continuous-time test system was modeled as a discrete-time, linear, shift-invariant system. In estimating the unit-sample response and frequency response of the discrete-time system, it was necessary to use digital filtering to remove low-amplitude noise, which interfered with deconvolution calculations. A digital bandpass filter constructed with the assistance of a Blackman window and a rectangular time window were used. Approximations of the impulse response and the frequency response of the continuous-time test system were obtained by linearly interpolating the defining points of the unit-sample response and the frequency response of the discrete-time system. The test system behaved as a linear-phase bandpass filter in the frequency range 0.6 to 2.3 MHz. These frequencies were selected in accordance with the criterion that they were 6 dB below the maximum peak of the amplitude of the frequency response. The output of the system to various inputs was predicted and the results were compared with the corresponding measurements on the system.

  15. Modular Elastomer Photoresins for Digital Light Processing Additive Manufacturing.

    PubMed

    Thrasher, Carl J; Schwartz, Johanna J; Boydston, Andrew J

    2017-11-15

    A series of photoresins suitable for the production of elastomeric objects via digital light processing additive manufacturing are reported. Notably, the printing procedure is readily accessible using only entry-level equipment under ambient conditions using visible light projection. The photoresin formulations were found to be modular in nature, and straightforward adjustments to the resin components enabled access to a range of compositions and mechanical properties. Collectively, the series includes silicones, hydrogels, and hybrids thereof. Printed test specimens displayed maximum elongations of up to 472% under tensile load, a tunable swelling behavior in water, and Shore A hardness values from 13.7 to 33.3. A combination of the resins was used to print a functional multimaterial three-armed pneumatic gripper. These photoresins could be transformative to advanced prototyping applications such as simulated human tissues, stimuli-responsive materials, wearable devices, and soft robotics.

  16. THz holography in reflection using a high resolution microbolometer array.

    PubMed

    Zolliker, Peter; Hack, Erwin

    2015-05-04

    We demonstrate a digital holographic setup for Terahertz imaging of surfaces in reflection. The set-up is based on a high-power continuous wave (CW) THz laser and a high-resolution (640 × 480 pixel) bolometer detector array. Wave propagation to non-parallel planes is used to reconstruct the object surface that is rotated relative to the detector plane. In addition we implement synthetic aperture methods for resolution enhancement and compare Fourier transform phase retrieval to phase stepping methods. A lateral resolution of 200 μm and a relative phase sensitivity of about 0.4 rad corresponding to a depth resolution of 6 μm are estimated from reconstructed images of two specially prepared test targets, respectively. We highlight the use of digital THz holography for surface profilometry as well as its potential for video-rate imaging.

  17. Finalizing the Dtag: implementation and testing of design improvements for reliability and availability

    DTIC Science & Technology

    2016-10-14

    ABSTRACT DTAGs have proven to be a valuable tool for the study of marine mammal acoustics and fine scale motion. The success of the DTAG has resulted in...Underwater Acoustics , Digital Communications 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF a. REPORT b. ABSTRACT c. THIS PAGE ABSTRACT u u u...continuously monitor and improve the tag design.\\ OBJECTIVES Dtags have proven to be a valuable tool for the study of marine mammal acoustics and fine

  18. Image understanding and the man-machine interface II; Proceedings of the Meeting, Los Angeles, CA, Jan. 17, 18, 1989

    NASA Technical Reports Server (NTRS)

    Barrett, Eamon B. (Editor); Pearson, James J. (Editor)

    1989-01-01

    Image understanding concepts and models, image understanding systems and applications, advanced digital processors and software tools, and advanced man-machine interfaces are among the topics discussed. Particular papers are presented on such topics as neural networks for computer vision, object-based segmentation and color recognition in multispectral images, the application of image algebra to image measurement and feature extraction, and the integration of modeling and graphics to create an infrared signal processing test bed.

  19. s48-e-013

    NASA Image and Video Library

    2012-11-08

    S48-E-013 (15 Sept 1991) --- The Upper Atmosphere Research Satellite (UARS) in the payload bay of the earth- orbiting Discovery. UARS is scheduled for deploy on flight day three of the STS-48 mission. Data from UARS will enable scientists to study ozone depletion in the stratosphere, or upper atmosphere. This image was transmitted by the Electronic Still Camera (ESC), Development Test Objective (DTO) 648. The ESC is making its initial appearance on a Space Shuttle flight. Electronic still photography is a new technology that enables a camera to electronically capture and digitize an image with resolution approaching film quality. The digital image is stored on removable hard disks or small optical disks, and can be converted to a format suitable for downlink transmission or enhanced using image processing software. The Electronic Still Camera (ESC) was developed by the Man- Systems Division at the Johnson Space Center and is the first model in a planned evolutionary development leading to a family of high-resolution digital imaging devices. H. Don Yeates, JSC's Man-Systems Division, is program manager for the ESC. THIS IS A SECOND GENERATION PRINT MADE FROM AN ELECTRONICALLY PRODUCED NEGATIVE.

  20. Digital X-ray portable scanner based on monolithic semi-insulating GaAs detectors: General description and first “quantum” images

    NASA Astrophysics Data System (ADS)

    Dubecký, F.; Perd'ochová, A.; Ščepko, P.; Zat'ko, B.; Sekerka, V.; Nečas, V.; Sekáčová, M.; Hudec, M.; Boháček, P.; Huran, J.

    2005-07-01

    The present work describes a portable digital X-ray scanner based on bulk undoped semi-insulating (SI) GaAs monolithic strip line detectors. The scanner operates in "quantum" imaging mode ("single photon counting"), with potential improvement of the dynamic range in contrast of the observed X-ray images. The "heart" of the scanner (detection unit) is based on SI GaAs strip line detectors. The measured detection efficiency of the SI GaAs detector reached a value of over 60 % (compared to the theoretical one of ˜75 %) for the detection of 60 keV photons at a reverse bias of 200 V. The read-out electronics consists of 20 modules fabricated using a progressive SMD technology with automatic assembly of electronic devices. Signals from counters included in the digital parts of the modules are collected in a PC via a USB port and evaluated by custom developed software allowing X-ray image reconstruction. The collected data were used for the creation of the first X-ray "quantum" images of various test objects using the imaging software developed.

  1. Phase aberration compensation of digital holographic microscopy based on least squares surface fitting

    NASA Astrophysics Data System (ADS)

    Di, Jianglei; Zhao, Jianlin; Sun, Weiwei; Jiang, Hongzhen; Yan, Xiaobo

    2009-10-01

    Digital holographic microscopy allows the numerical reconstruction of the complex wavefront of samples, especially biological samples such as living cells. In digital holographic microscopy, a microscope objective is introduced to improve the transverse resolution of the sample; however a phase aberration in the object wavefront is also brought along, which will affect the phase distribution of the reconstructed image. We propose here a numerical method to compensate for the phase aberration of thin transparent objects with a single hologram. The least squares surface fitting with points number less than the matrix of the original hologram is performed on the unwrapped phase distribution to remove the unwanted wavefront curvature. The proposed method is demonstrated with the samples of the cicada wings and epidermal cells of garlic, and the experimental results are consistent with that of the double exposure method.

  2. 77 FR 50722 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-22

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software...) is issuing for public comment draft regulatory guide (DG), DG-1208, ``Software Unit Testing for Digital Computer Software used in Safety Systems of Nuclear Power Plants.'' The DG-1208 is proposed...

  3. 78 FR 47011 - Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-02

    ... NUCLEAR REGULATORY COMMISSION [NRC-2012-0195] Software Unit Testing for Digital Computer Software... revised regulatory guide (RG), revision 1 of RG 1.171, ``Software Unit Testing for Digital Computer Software Used in Safety Systems of Nuclear Power Plants.'' This RG endorses American National Standards...

  4. Multi-finger Prehension: An overview

    PubMed Central

    Zatsiorsky, Vladimir M.; Latash, Mark L.

    2009-01-01

    This paper reviews the available experimental evidence on what people do when they grasp an object with several digits and then manipulate it. In addition to the Introduction, the paper includes three parts each addressing a specific aspect of multi-finger prehension. Part II discusses manipulation forces, i.e. the resultant force and moment of force exerted on the object, and the digits contribution to such force production. Part III deals with internal forces defined as forces that cancel each other and do not disturb object equilibrium. The role of the internal forces in maintaining the object stability is discussed with respect to such issues as slip prevention, tilt prevention and resistance to perturbations. Part IV is devoted to the motor control of prehension. It covers such topics as prehension synergies, chain effects, the principle of superposition, inter-finger connection matrices and reconstruction of neural commands, mechanical advantage of the fingers, and the simultaneous digit adjustment to several mutually reinforcing or conflicting demands. PMID:18782719

  5. Influences and Practices in Colorectal Cancer Screening Among Health Care Providers Serving Northern Plains American Indians, 2011-2012.

    PubMed

    Nadeau, Melanie; Walaszek, Anne; Perdue, David G; Rhodes, Kristine L; Haverkamp, Donald; Forster, Jean

    2016-12-15

    The epidemiology of colorectal cancer, including incidence, mortality, age of onset, stage of diagnosis, and screening, varies regionally among American Indians. The objective of the Improving Northern Plains American Indian Colorectal Cancer Screening study was to improve understanding of colorectal cancer screening among health care providers serving Northern Plains American Indians. Data were collected, in person, from a sample of 145 health care providers at 27 health clinics across the Northern Plains from May 2011 through September 2012. Participants completed a 32-question, self-administered assessment designed to assess provider practices, screening perceptions, and knowledge. The proportion of providers who ordered or performed at least 1 colorectal cancer screening test for an asymptomatic, average-risk patient in the previous month was 95.9% (139 of 145). Of these 139 providers, 97.1% ordered colonoscopies, 12.9% ordered flexible sigmoidoscopies, 73.4% ordered 3-card, guaiac-based, fecal occult blood tests, and 21.6% ordered fecal immunochemical tests. Nearly two-thirds (64.7%) reported performing in-office guaiac-based fecal occult blood tests using digital rectal examination specimens. Providers who reported receiving a formal update on colorectal cancer screening during the previous 24 months were more likely to screen using digital rectal exam specimens than providers who had received a formal update on colorectal cancer screening more than 24 months prior (73.9% vs 56.9%, respectively, χ 2 = 4.29, P = .04). Despite recommendations cautioning against the use of digital rectal examination specimens for colorectal cancer screening, the practice is common among providers serving Northern Plains American Indian populations. Accurate up-to-date, ongoing education for patients, the community, and health care providers is needed.

  6. Flight test validation of a design procedure for digital autopilots

    NASA Technical Reports Server (NTRS)

    Bryant, W. H.

    1983-01-01

    Commercially available general aviation autopilots are currently in transition from an analogue circuit system to a computer implemented digital flight control system. Well known advantages of the digital autopilot include enhanced modes, self-test capacity, fault detection, and greater computational capacity. A digital autopilot's computational capacity can be used to full advantage by increasing the sophistication of the digital autopilot's chief function, stability and control. NASA's Langley Research Center has been pursuing the development of direct digital design tools for aircraft stabilization systems for several years. This effort has most recently been directed towards the development and realization of multi-mode digital autopilots for GA aircraft, conducted under a SPIFR-related program called the General Aviation Terminal Operations Research (GATOR) Program. This presentation focuses on the implementation and testing of a candidate multi-mode autopilot designed using these newly developed tools.

  7. Comparison of flight results with digital simulation for a digital electronic engine control in an F-15 airplane

    NASA Technical Reports Server (NTRS)

    Myers, L. P.; Burcham, F. W., Jr.

    1983-01-01

    Substantial benefits of a full authority digital electronic engine control on an air breathing engine were demonstrated repeatedly in simulation studies, ground engine tests, and engine altitude test facilities. A digital engine electronic control system showed improvements in efficiency, performance, and operation. An additional benefit of full authority digital controls is the capability of detecting and correcting failures and providing engine health diagnostics.

  8. Random lattice structures. Modelling, manufacture and FEA of their mechanical response

    NASA Astrophysics Data System (ADS)

    Maliaris, G.; Sarafis, I. T.; Lazaridis, T.; Varoutoglou, A.; Tsakataras, G.

    2016-11-01

    The implementation of lightweight structures in various applications, especially in Aerospace/ Automotive industries and Orthopaedics, has become a necessity due to their exceptional mechanical properties with respect to reduced weight. In this work we present a Voronoi tessellation based algorithm, which has been developed for modelling stochastic lattice structures. With the proposed algorithm, is possible to generate CAD geometry with controllable structural parameters, such as porosity, cell number and strut thickness. The digital structures were transformed into physical objects through the combination of 3D printing technics and investment casting. This process was applied to check the mechanical behaviour of generated digital models. Until now, the only way to materialize such structures into physical objects, was feasible through 3D printing methods such as Selective Laser Sintering/ Melting (SLS/ SLM). Investment casting possesses numerous advantages against SLS or SLA, with the major one being the material variety. On the other hand, several trials are required in order to calibrate the process parameters to have successful castings, which is the major drawback of investment casting. The manufactured specimens were subjected to compression tests, where their mechanical response was registered in the form of compressive load - displacement curves. Also, a finite element model was developed, using the specimens’ CAD data and compression test parameters. The FE assisted calculation of specimen plastic deformation is identical with the one of the physical object, which validates the conclusions drawn from the simulation results. As it was observed, strut contact is initiated when specimen deformation is approximately 5mm. Although FE calculated compressive force follows the same trend for the first 3mm of compression, then diverges because of the elasto-plastic FE model type definition and the occurred remeshing steps.

  9. Digital spiral-slit for bi-photon imaging

    NASA Astrophysics Data System (ADS)

    McLaren, Melanie; Forbes, Andrew

    2017-04-01

    Quantum ghost imaging using entangled photon pairs has become a popular field of investigation, highlighting the quantum correlation between the photon pairs. We introduce a technique using spatial light modulators encoded with digital holograms to recover both the amplitude and the phase of the digital object. Down-converted photon pairs are entangled in the orbital angular momentum basis, and are commonly measured using spiral phase holograms. Consequently, by encoding a spiral ring-slit hologram into the idler arm, and varying it radially we can simultaneously recover the phase and amplitude of the object in question. We demonstrate that a good correlation between the encoded field function and the reconstructed images exists.

  10. Cyclic Crack Growth Testing of an A.O. Smith Multilayer Pressure Vessel with Modal Acoustic Emission Monitoring and Data Assessment

    NASA Technical Reports Server (NTRS)

    Ziola, Steven M.

    2014-01-01

    Digital Wave Corp. (DWC) was retained by Jacobs ATOM at NASA Ames Research Center to perform cyclic pressure crack growth sensitivity testing on a multilayer pressure vessel instrumented with DWC's Modal Acoustic Emission (MAE) system, with captured wave analysis to be performed using DWCs WaveExplorerTM software, which has been used at Ames since 2001. The objectives were to document the ability to detect and characterize a known growing crack in such a vessel using only MAE, to establish the sensitivity of the equipment vs. crack size and / or relevance in a realistic field environment, and to obtain fracture toughness materials properties in follow up testing to enable accurate crack growth analysis. This report contains the results of the testing.

  11. Background compensation for a radiation level monitor

    DOEpatents

    Keefe, D.J.

    1975-12-01

    Background compensation in a device such as a hand and foot monitor is provided by digital means using a scaler. With no radiation level test initiated, a scaler is down-counted from zero according to the background measured. With a radiation level test initiated, the scaler is up-counted from the previous down-count position according to the radiation emitted from the monitored object and an alarm is generated if, with the scaler having crossed zero in the positive going direction, a particular number is exceeded in a specific time period after initiation of the test. If the test is initiated while the scale is down-counting, the background count from the previous down- count stored in a memory is used as the initial starting point for the up-count.

  12. Imaging Surveillance After Primary Breast Cancer Treatment

    PubMed Central

    Lam, Diana L.; Houssami, Nehmat; Lee, Janie M.

    2017-01-01

    OBJECTIVE Current clinical guidelines are consistent in supporting annual mammography for women after treatment of primary breast cancer. Surveillance imaging beyond standard digital mammography, including digital breast tomosynthesis (DBT), breast ultrasound, and MRI, may improve outcomes. This article reviews the evidence on the performance and effectiveness of breast imaging modalities available for surveillance after treatment of sporadic unilateral primary breast cancer and identifies additional factors to be considered when selecting an imaging surveillance regimen. CONCLUSION Evidence review supports the use of mammography for surveillance after primary breast cancer treatment. Variability exists in guideline recommendations for surveillance initiation, interval, and cessation. DBT offers the most promise as a potential modality to replace standard digital mammography as a front-line surveillance test; a single published study to date has shown a significant decrease in recall rates compared with standard digital mammography alone. Most guidelines do not support the use of whole-breast ultrasound in breast cancer surveillance, and further studies are needed to define the characteristics of women who may benefit from MRI surveillance. The emerging evidence about surveillance imaging outcomes suggests that additional factors, including patient and imaging characteristics, tumor biology and gene expression profile, and choice of treatment, warrant consideration in selecting personalized posttreatment imaging surveillance regimens. PMID:28075622

  13. Total internal reflection holographic microscopy (TIRHM) for quantitative phase characterization of cell-substrate adhesion

    NASA Astrophysics Data System (ADS)

    Ash, William Mason, III

    Total Internal Reflection Holographic Microscopy (TIRHM) combines near-field microscopy with digital holography to produce a new form of near-field phase microscopy. Using a prism in TIR as a near-field imager, the presence of microscopic organisms, cell-substrate interfaces, and adhesions, causes relative refractive index (RRI) and frustrated TIR (f-TIR) to modulate the object beam's evanescent wave phase front. Quantitative phase images of test specimens such as Amoeba proteus, Dictyostelium Discoideum and cells such as SKOV-3 ovarian cancer and 3T3 fibroblasts are produced without the need to introduce stains or fluorophores. The angular spectrum method of digital holography to compensate for tilt anamorphism due to the inclined TIR plane is also discussed. The results of this work conclusively demonstrate, for the first time, the integration of near-field microscopy with digital holography. The cellular images presented show a correlation between the physical extent of the Amoeba proteus plasma membrane and the adhesions that are quantitatively profiled by phase cross-sectioning of the holographic images obtained by digital holography. With its ability to quantitatively characterise cellular adhesion and motility, it is anticipated that TIRHM can be a tool for characterizing and combating cancer metastasis, as well as improving our understanding of morphogenesis and embryogenesis itself.

  14. The reliability and reproducibility of cephalometric measurements: a comparison of conventional and digital methods

    PubMed Central

    AlBarakati, SF; Kula, KS; Ghoneima, AA

    2012-01-01

    Objective The aim of this study was to assess the reliability and reproducibility of angular and linear measurements of conventional and digital cephalometric methods. Methods A total of 13 landmarks and 16 skeletal and dental parameters were defined and measured on pre-treatment cephalometric radiographs of 30 patients. The conventional and digital tracings and measurements were performed twice by the same examiner with a 6 week interval between measurements. The reliability within the method was determined using Pearson's correlation coefficient (r2). The reproducibility between methods was calculated by paired t-test. The level of statistical significance was set at p < 0.05. Results All measurements for each method were above 0.90 r2 (strong correlation) except maxillary length, which had a correlation of 0.82 for conventional tracing. Significant differences between the two methods were observed in most angular and linear measurements except for ANB angle (p = 0.5), angle of convexity (p = 0.09), anterior cranial base (p = 0.3) and the lower anterior facial height (p = 0.6). Conclusion In general, both methods of conventional and digital cephalometric analysis are highly reliable. Although the reproducibility of the two methods showed some statistically significant differences, most differences were not clinically significant. PMID:22184624

  15. Digit Span as a measure of everyday attention: a study of ecological validity.

    PubMed

    Groth-Marnat, Gary; Baker, Sonya

    2003-12-01

    This study investigated the effectiveness of the WAIS-III Digit Span subtest to predict the everyday attention of 75 participants with heterogeneous neurological conditions who were administered the Digit Span subtest as well as the ecologically valid Test of Everyday Attention. In addition, the more visually oriented Picture Completion subtest along with the verbally loaded National Adult Reading Test were administered. Analysis indicated that, although Digit Span was a weak but statistically significant predictor of attentional ability (accounting for 12.7% of the unique variance). Picture Completion was a somewhat stronger predictor (accounting for 19% of the unique variance). The weak association of Digit Span and the Test of Everyday Attention, along with the finding that Picture Completion was a better predictor of performance on the Test of Everyday Attention, question the clinical utility of using Digit Span as a measure of everyday attention.

  16. A multiparametric automatic method to monitor long-term reproducibility in digital mammography: results from a regional screening programme.

    PubMed

    Gennaro, G; Ballaminut, A; Contento, G

    2017-09-01

    This study aims to illustrate a multiparametric automatic method for monitoring long-term reproducibility of digital mammography systems, and its application on a large scale. Twenty-five digital mammography systems employed within a regional screening programme were controlled weekly using the same type of phantom, whose images were analysed by an automatic software tool. To assess system reproducibility levels, 15 image quality indices (IQIs) were extracted and compared with the corresponding indices previously determined by a baseline procedure. The coefficients of variation (COVs) of the IQIs were used to assess the overall variability. A total of 2553 phantom images were collected from the 25 digital mammography systems from March 2013 to December 2014. Most of the systems showed excellent image quality reproducibility over the surveillance interval, with mean variability below 5%. Variability of each IQI was 5%, with the exception of one index associated with the smallest phantom objects (0.25 mm), which was below 10%. The method applied for reproducibility tests-multi-detail phantoms, cloud automatic software tool to measure multiple image quality indices and statistical process control-was proven to be effective and applicable on a large scale and to any type of digital mammography system. • Reproducibility of mammography image quality should be monitored by appropriate quality controls. • Use of automatic software tools allows image quality evaluation by multiple indices. • System reproducibility can be assessed comparing current index value with baseline data. • Overall system reproducibility of modern digital mammography systems is excellent. • The method proposed and applied is cost-effective and easily scalable.

  17. 3D motion picture of transparent gas flow by parallel phase-shifting digital holography

    NASA Astrophysics Data System (ADS)

    Awatsuji, Yasuhiro; Fukuda, Takahito; Wang, Yexin; Xia, Peng; Kakue, Takashi; Nishio, Kenzo; Matoba, Osamu

    2018-03-01

    Parallel phase-shifting digital holography is a technique capable of recording three-dimensional (3D) motion picture of dynamic object, quantitatively. This technique can record single hologram of an object with an image sensor having a phase-shift array device and reconstructs the instantaneous 3D image of the object with a computer. In this technique, a single hologram in which the multiple holograms required for phase-shifting digital holography are multiplexed by using space-division multiplexing technique pixel by pixel. We demonstrate 3D motion picture of dynamic and transparent gas flow recorded and reconstructed by the technique. A compressed air duster was used to generate the gas flow. A motion picture of the hologram of the gas flow was recorded at 180,000 frames/s by parallel phase-shifting digital holography. The phase motion picture of the gas flow was reconstructed from the motion picture of the hologram. The Abel inversion was applied to the phase motion picture and then the 3D motion picture of the gas flow was obtained.

  18. Objective analysis of image quality of video image capture systems

    NASA Astrophysics Data System (ADS)

    Rowberg, Alan H.

    1990-07-01

    As Picture Archiving and Communication System (PACS) technology has matured, video image capture has become a common way of capturing digital images from many modalities. While digital interfaces, such as those which use the ACR/NEMA standard, will become more common in the future, and are preferred because of the accuracy of image transfer, video image capture will be the dominant method in the short term, and may continue to be used for some time because of the low cost and high speed often associated with such devices. Currently, virtually all installed systems use methods of digitizing the video signal that is produced for display on the scanner viewing console itself. A series of digital test images have been developed for display on either a GE CT9800 or a GE Signa MRI scanner. These images have been captured with each of five commercially available image capture systems, and the resultant images digitally transferred on floppy disk to a PC1286 computer containing Optimast' image analysis software. Here the images can be displayed in a comparative manner for visual evaluation, in addition to being analyzed statistically. Each of the images have been designed to support certain tests, including noise, accuracy, linearity, gray scale range, stability, slew rate, and pixel alignment. These image capture systems vary widely in these characteristics, in addition to the presence or absence of other artifacts, such as shading and moire pattern. Other accessories such as video distribution amplifiers and noise filters can also add or modify artifacts seen in the captured images, often giving unusual results. Each image is described, together with the tests which were performed using them. One image contains alternating black and white lines, each one pixel wide, after equilibration strips ten pixels wide. While some systems have a slew rate fast enough to track this correctly, others blur it to an average shade of gray, and do not resolve the lines, or give horizontal or vertical streaking. While many of these results are significant from an engineering standpoint alone, there are clinical implications and some anatomy or pathology may not be visualized if an image capture system is used improperly.

  19. Combining Imaging and Non-Imaging Observations for Improved Space-Object Identification

    DTIC Science & Technology

    2011-09-27

    Optical and Digital Superresolution Early in the project, we expolited Fisher information (FI) to characterize the extent of spatial-frequency...extrapolation beyond the diffraction-limited optical bandwidth when the support of the object is known a priori. This support-assisted optical superresolution ...both digital (DSR) and optical superresolution (OSR). Indeed, by analyzing a se- quence of sub-pixel-shifted undersampled images one can show the

  20. Guiding Age 10-11 Students to Notice the Salient Features of Physical Change Models in Chemistry Digital Learning Objects

    ERIC Educational Resources Information Center

    Gustafson, Brenda; Mahaffy, Peter; Martin, Brian

    2015-01-01

    This paper focuses on one Grade 5 class (9 females; 9 males) who worked in student-pairs to view five digital learning object (DLO) lessons created by the authors and meant to introduce students to the nature of models, the particle nature of matter, and physical change. Specifically, the paper focuses on whether DLO design elements could assist…

  1. A New Approach for Inspection of Selected Geometric Parameters of a Railway Track Using Image-Based Point Clouds

    PubMed Central

    Sawicki, Piotr

    2018-01-01

    The paper presents the results of testing a proposed image-based point clouds measuring method for geometric parameters determination of a railway track. The study was performed based on a configuration of digital images and reference control network. A DSLR (digital Single-Lens-Reflex) Nikon D5100 camera was used to acquire six digital images of the tested section of railway tracks. The dense point clouds and the 3D mesh model were generated with the use of two software systems, RealityCapture and PhotoScan, which have implemented different matching and 3D object reconstruction techniques: Multi-View Stereo and Semi-Global Matching, respectively. The study found that both applications could generate appropriate 3D models. Final meshes of 3D models were filtered with the MeshLab software. The CloudCompare application was used to determine the track gauge and cant for defined cross-sections, and the results obtained from point clouds by dense image matching techniques were compared with results of direct geodetic measurements. The obtained RMS difference in the horizontal (gauge) and vertical (cant) plane was RMS∆ < 0.45 mm. The achieved accuracy meets the accuracy condition of measurements and inspection of the rail tracks (error m < 1 mm), specified in the Polish branch railway instruction Id-14 (D-75) and the European technical norm EN 13848-4:2011. PMID:29509679

  2. A New Approach for Inspection of Selected Geometric Parameters of a Railway Track Using Image-Based Point Clouds.

    PubMed

    Gabara, Grzegorz; Sawicki, Piotr

    2018-03-06

    The paper presents the results of testing a proposed image-based point clouds measuring method for geometric parameters determination of a railway track. The study was performed based on a configuration of digital images and reference control network. A DSLR (digital Single-Lens-Reflex) Nikon D5100 camera was used to acquire six digital images of the tested section of railway tracks. The dense point clouds and the 3D mesh model were generated with the use of two software systems, RealityCapture and PhotoScan, which have implemented different matching and 3D object reconstruction techniques: Multi-View Stereo and Semi-Global Matching, respectively. The study found that both applications could generate appropriate 3D models. Final meshes of 3D models were filtered with the MeshLab software. The CloudCompare application was used to determine the track gauge and cant for defined cross-sections, and the results obtained from point clouds by dense image matching techniques were compared with results of direct geodetic measurements. The obtained RMS difference in the horizontal (gauge) and vertical (cant) plane was RMS∆ < 0.45 mm. The achieved accuracy meets the accuracy condition of measurements and inspection of the rail tracks (error m < 1 mm), specified in the Polish branch railway instruction Id-14 (D-75) and the European technical norm EN 13848-4:2011.

  3. Can Commercial Digital Cameras Be Used as Multispectral Sensors? A Crop Monitoring Test.

    PubMed

    Lebourgeois, Valentine; Bégué, Agnès; Labbé, Sylvain; Mallavan, Benjamin; Prévot, Laurent; Roux, Bruno

    2008-11-17

    The use of consumer digital cameras or webcams to characterize and monitor different features has become prevalent in various domains, especially in environmental applications. Despite some promising results, such digital camera systems generally suffer from signal aberrations due to the on-board image processing systems and thus offer limited quantitative data acquisition capability. The objective of this study was to test a series of radiometric corrections having the potential to reduce radiometric distortions linked to camera optics and environmental conditions, and to quantify the effects of these corrections on our ability to monitor crop variables. In 2007, we conducted a five-month experiment on sugarcane trial plots using original RGB and modified RGB (Red-Edge and NIR) cameras fitted onto a light aircraft. The camera settings were kept unchanged throughout the acquisition period and the images were recorded in JPEG and RAW formats. These images were corrected to eliminate the vignetting effect, and normalized between acquisition dates. Our results suggest that 1) the use of unprocessed image data did not improve the results of image analyses; 2) vignetting had a significant effect, especially for the modified camera, and 3) normalized vegetation indices calculated with vignetting-corrected images were sufficient to correct for scene illumination conditions. These results are discussed in the light of the experimental protocol and recommendations are made for the use of these versatile systems for quantitative remote sensing of terrestrial surfaces.

  4. Development of real-time extensometer based on image processing

    NASA Astrophysics Data System (ADS)

    Adinanta, H.; Puranto, P.; Suryadi

    2017-04-01

    An extensometer system was developed by using high definition web camera as main sensor to track object position. The developed system applied digital image processing techniques. The image processing was used to measure the change of object position. The position measurement was done in real-time so that the system can directly showed the actual position in both x and y-axis. In this research, the relation between pixel and object position changes had been characterized. The system was tested by moving the target in a range of 20 cm in interval of 1 mm. To verify the long run performance, the stability and linearity of continuous measurements on both x and y-axis, this measurement had been conducted for 83 hours. The results show that this image processing-based extensometer had both good stability and linearity.

  5. Impairment of Concept Formation Ability in Children with ADHD: Comparisons between Lower Grades and Higher Grades

    PubMed Central

    Hong, Hye Jeong; Kim, Jin Sung; Seo, Wan Seok; Koo, Bon Hoon; Bai, Dai Seg; Jeong, Jin Young

    2010-01-01

    Objective We investigated executive functions (EFs), as evaluated by the Wisconsin Card Sorting Test (WCST), and other EF between lower grades (LG) and higher grades (HG) in elementary-school-age attention deficit hyperactivity disorder (ADHD) children. Methods We classified a sample of 112 ADHD children into 4 groups (composed of 28 each) based on age (LG vs. HG) and WCST performance [lower vs. higher performance on WCST, defined by the number of completed categories (CC)] Participants in each group were matched according to age, gender, ADHD subtype, and intelligence. We used the Wechsler intelligence Scale for Children 3rd edition to test intelligence and the Computerized Neurocognitive Function Test-IV, which included the WCST, to test EF. Results Comparisons of EFs scores in LG ADHD children showed statistically significant differences in performing digit spans backward, some verbal learning scores, including all memory scores, and Stroop test scores. However, comparisons of EF scores in HG ADHD children did not show any statistically significant differences. Correlation analyses of the CC and EF variables and stepwise multiple regression analysis in LG ADHD children showed a combination of the backward form of the Digit span test and Visual span test in lower-performance ADHD participants significantly predicted the number of CC (R2=0.273, p<0.001). Conclusion This study suggests that the design of any battery of neuropsychological tests for measuring EF in ADHD children should first consider age before interpreting developmental variations and neuropsychological test results. Researchers should consider the dynamics of relationships within EF, as measured by neuropsychological tests. PMID:20927306

  6. Dissociations in the expression of the sedative effects of triazolam.

    PubMed

    Weingartner, H J; Sirocco, K; Rawlings, R; Joyce, E; Hommer, D

    1995-05-01

    Fifteen normal volunteers were administered 0.250, 0.375, and 0.500 mg of triazolam and placebo in a double-blind repeated measures cross-over design. Subjects demonstrated dose-dependent impairments in free recall, a test of explicit memory requiring awareness and reflection, and sedation as assessed by objective behavioral measures (the digit symbol substitution task) and subjective visual analogue scales. The sedative drug response did not account for the impairment in free recall. Differences in performance of the two tests of sedation indicated that the effect of this drug on reflective processes accounts for impairment in episodic memory and the inability to track the sedative effects of this drug at the higher doses tested in this study.

  7. Digital Preservation and Deep Infrastructure; Dublin Core Metadata Initiative Progress Report and Workplan for 2002; Video Gaming, Education and Digital Learning Technologies: Relevance and Opportunities; Digital Collections of Real World Objects; The MusArt Music-Retrieval System: An Overview; eML: Taking Mississippi Libraries into the 21st Century.

    ERIC Educational Resources Information Center

    Granger, Stewart; Dekkers, Makx; Weibel, Stuart L.; Kirriemuir, John; Lensch, Hendrik P. A.; Goesele, Michael; Seidel, Hans-Peter; Birmingham, William; Pardo, Bryan; Meek, Colin; Shifrin, Jonah; Goodvin, Renee; Lippy, Brooke

    2002-01-01

    One opinion piece and five articles in this issue discuss: digital preservation infrastructure; accomplishments and changes in the Dublin Core Metadata Initiative in 2001 and plans for 2002; video gaming and how it relates to digital libraries and learning technologies; overview of a music retrieval system; and the online version of the…

  8. Dual-channel in-line digital holographic double random phase encryption

    PubMed Central

    Das, Bhargab; Yelleswarapu, Chandra S; Rao, D V G L N

    2012-01-01

    We present a robust encryption method for the encoding of 2D/3D objects using digital holography and virtual optics. Using our recently developed dual-plane in-line digital holography technique, two in-line digital holograms are recorded at two different planes and are encrypted using two different double random phase encryption configurations, independently. The process of using two mutually exclusive encryption channels makes the system more robust against attacks since both the channels should be decrypted accurately in order to get a recognizable reconstruction. Results show that the reconstructed object is unrecognizable even when the portion of the correct phase keys used during decryption is close to 75%. The system is verified against blind decryptions by evaluating the SNR and MSE. Validation of the proposed method and sensitivities of the associated parameters are quantitatively analyzed and illustrated. PMID:23471012

  9. Polarization microscopy by use of digital holography: application to optical-fiber birefringence measurements.

    PubMed

    Colomb, Tristan; Dürr, Florian; Cuche, Etienne; Marquet, Pierre; Limberger, Hans G; Salathé, René-Paul; Depeursinge, Christian

    2005-07-20

    We present a digital holographic microscope that permits one to image polarization state. This technique results from the coupling of digital holographic microscopy and polarization digital holography. The interference between two orthogonally polarized reference waves and the wave transmitted by a microscopic sample, magnified by a microscope objective, is recorded on a CCD camera. The off-axis geometry permits one to reconstruct separately from this single hologram two wavefronts that are used to image the object-wave Jones vector. We applied this technique to image the birefringence of a bent fiber. To evaluate the precision of the phase-difference measurement, the birefringence induced by internal stress in an optical fiber is measured and compared to the birefringence profile captured by a standard method, which had been developed to obtain high-resolution birefringence profiles of optical fibers.

  10. A Taxonomy of 3D Occluded Objects Recognition Techniques

    NASA Astrophysics Data System (ADS)

    Soleimanizadeh, Shiva; Mohamad, Dzulkifli; Saba, Tanzila; Al-ghamdi, Jarallah Saleh

    2016-03-01

    The overall performances of object recognition techniques under different condition (e.g., occlusion, viewpoint, and illumination) have been improved significantly in recent years. New applications and hardware are shifted towards digital photography, and digital media. This faces an increase in Internet usage requiring object recognition for certain applications; particularly occulded objects. However occlusion is still an issue unhandled, interlacing the relations between extracted feature points through image, research is going on to develop efficient techniques and easy to use algorithms that would help users to source images; this need to overcome problems and issues regarding occlusion. The aim of this research is to review recognition occluded objects algorithms and figure out their pros and cons to solve the occlusion problem features, which are extracted from occluded object to distinguish objects from other co-existing objects by determining the new techniques, which could differentiate the occluded fragment and sections inside an image.

  11. Spatially-Heterodyned Holography

    DOEpatents

    Thomas, Clarence E [Knoxville, TN; Hanson, Gregory R [Clinton, TN

    2006-02-21

    A method of recording a spatially low-frequency heterodyne hologram, including spatially heterodyne fringes for Fourier analysis, includes: splitting a laser beam into a reference beam and an object beam; interacting the object beam with an object; focusing the reference beam and the object beam at a focal plane of a digital recorder to form a spatially low-frequency heterodyne hologram including spatially heterodyne fringes for Fourier analysis; digital recording the spatially low-frequency heterodyne hologram; Fourier transforming axes of the recorded spatially low-frequency heterodyne hologram including spatially heterodyne fringes in Fourier space to sit on top of a heterodyne carrier frequency defined by an angle between the reference beam and the object beam; cutting off signals around an origin; and performing an inverse Fourier transform.

  12. Documentation and Detection of Colour Changes of Bas Relieves Using Close Range Photogrammetry

    NASA Astrophysics Data System (ADS)

    Malinverni, E. S.; Pierdicca, R.; Sturari, M.; Colosi, F.; Orazi, R.

    2017-05-01

    The digitization of complex buildings, findings or bas relieves can strongly facilitate the work of archaeologists, mainly for in depth analysis tasks. Notwithstanding, whether new visualization techniques ease the study phase, a classical naked-eye approach for determining changes or surface alteration could bring towards several drawbacks. The research work described in these pages is aimed at providing experts with a workflow for the evaluation of alterations (e.g. color decay or surface alterations), allowing a more rapid and objective monitoring of monuments. More in deep, a pipeline of work has been tested in order to evaluate the color variation between surfaces acquired at different époques. The introduction of reliable tools of change detection in the archaeological domain is needful; in fact, the most widespread practice, among archaeologists and practitioners, is to perform a traditional monitoring of surfaces that is made of three main steps: production of a hand-made map based on a subjective analysis, selection of a sub-set of regions of interest, removal of small portion of surface for in depth analysis conducted in laboratory. To overcome this risky and time consuming process, digital automatic change detection procedure represents a turning point. To do so, automatic classification has been carried out according to two approaches: a pixel-based and an object-based method. Pixel-based classification aims to identify the classes by means of the spectral information provided by each pixel belonging to the original bands. The object-based approach operates on sets of pixels (objects/regions) grouped together by means of an image segmentation technique. The methodology was tested by studying the bas-relieves of a temple located in Peru, named Huaca de la Luna. Despite the data sources were collected with unplanned surveys, the workflow proved to be a valuable solution useful to understand which are the main changes over time.

  13. The Digital Divide as Cultural Practice: A Cognitive Anthropological Exploration of Japan as an "Information Society"

    ERIC Educational Resources Information Center

    Kimura, Tadamasa

    2010-01-01

    The objective of this dissertation is to explore the socio-cultural contextualization of the digital divide in Japanese society. I undertake this task by developing a theoretical and methodological framework based on the notion of "culture as models," while explicating the cultural dimensions of the digital divide and the dynamics of…

  14. The Materiality of Digital Collections: Theoretical and Historical Perspectives

    ERIC Educational Resources Information Center

    Manoff, Marlene

    2006-01-01

    Digital and textual objects are coming under a new kind of scrutiny as scholars are becoming more interested in physical artifacts and their relation to their social and cultural environment. This study of material culture suggests a need to explore the nature of digital materiality, as well as the broader historical context in which electronic…

  15. A Study of Supplementing Conventional Business Education with Digital Games

    ERIC Educational Resources Information Center

    Ellahi, Abida; Zaka, Bilal; Sultan, Fahd

    2017-01-01

    This paper documents how the adoption of digital games by academia reshapes the current worldview by bringing the potential answers for all learning issues. The central objective of this study is to investigate the extent to which digital games can impact learning effectiveness, and to what extent these games can be used as supplementary elements…

  16. PATRON: Using a Multimedia Digital Library for Learning and Teaching in the Performing Arts.

    ERIC Educational Resources Information Center

    Lyon, Elizabeth

    The creation and application of a multimedia digital library to support learning and teaching in the performing arts is described. PATRON (Performing Arts Teaching Resources Online) delivers audio, video, music scores, dance notation, and theater scripts to the desktop via an innovative Web-based interface. Digital objects are linked subjectively…

  17. Digital-Difference Processing For Collision Avoidance.

    NASA Technical Reports Server (NTRS)

    Shores, Paul; Lichtenberg, Chris; Kobayashi, Herbert S.; Cunningham, Allen R.

    1988-01-01

    Digital system for automotive crash avoidance measures and displays difference in frequency between two sinusoidal input signals of slightly different frequencies. Designed for use with Doppler radars. Characterized as digital mixer coupled to frequency counter measuring difference frequency in mixer output. Technique determines target path mathematically. Used for tracking cars, missiles, bullets, baseballs, and other fast-moving objects.

  18. Metadata Harvesting in Regional Digital Libraries in the PIONIER Network

    ERIC Educational Resources Information Center

    Mazurek, Cezary; Stroinski, Maciej; Werla, Marcin; Weglarz, Jan

    2006-01-01

    Purpose: The paper aims to present the concept of the functionality of metadata harvesting for regional digital libraries, based on the OAI-PMH protocol. This functionality is a part of regional digital libraries platform created in Poland. The platform was required to reach one of main objectives of the Polish PIONIER Programme--to enrich the…

  19. A Survey of the University Students' Perspectives about Using Digital Technologies in Education: Zimbabwean Case

    ERIC Educational Resources Information Center

    Dube, Sibusisiwe; Scott, Elsje

    2017-01-01

    This study investigated the perspectives of university students on the use of digital technologies as tools for teaching and learning. Digital technologies are an essential asset for academic institutions as they can support strategic teaching and learning objectives for education institutions. Studies have shown that limited use of digital…

  20. A Search for Nontoroidal Topological Lensing in the Sloan Digital Sky Survey Quasar Catalog

    NASA Astrophysics Data System (ADS)

    Fujii, Hirokazu; Yoshii, Yuzuru

    2013-08-01

    Flat space models with multiply connected topology, which have compact dimensions, are tested against the distribution of high-redshift (z >= 4) quasars of the Sloan Digital Sky Survey (SDSS). When the compact dimensions are smaller in size than the observed universe, topological lensing occurs, in which multiple images of single objects (ghost images) are observed. We improve on the recently introduced method to identify ghost images by means of four-point statistics. Our method is valid for any of the 17 multiply connected flat models, including nontoroidal ones that are compacted by screw motions or glide reflection. Applying the method to the data revealed one possible case of topological lensing caused by sixth-turn screw motion, however, it is consistent with the simply connected model by this test alone. Moreover, simulations suggest that we cannot exclude the other space models despite the absence of their signatures. This uncertainty mainly originates from the patchy coverage of SDSS in the south Galactic cap, and this situation will be improved by future wide-field spectroscopic surveys.

  1. Structured Course Objects in a Digital Library

    NASA Technical Reports Server (NTRS)

    Maly, K.; Zubair, M.; Liu, X.; Nelson, M.; Zeil, S.

    1999-01-01

    We are developing an Undergraduate Digital Library Framework (UDLF) that will support creation/archiving of courses and reuse of existing course material to evolve courses. UDLF supports the publication of course materials for later instantiation for a specific offering and allows the addition of time-dependent and student-specific information and structures. Instructors and, depending on permissions, students can access the general course materials or the materials for a specific offering. We are building a reference implementation based on NCSTRL+, a digital library derived from NCSTRL. Digital objects in NCSTRL+ are called buckets, self-contained entities that carry their own methods for access and display. Current bucket implementations have a two level structure of packages and elements. This is not a rich enough structure for course objects in UDLF. Typically, courses can only be modeled as a multilevel hierarchy and among different courses, both the syntax and semantics of terms may vary. Therefore, we need a mechanism to define, within a particular library, course models, their constituent objects, and the associated semantics in a flexible, extensible way. In this paper, we describe our approach to define and implement these multilayered course objects. We use XML technology to emulate complex data structures within the NCSTRL+ buckets. We have developed authoring and browsing tools to manipulate these course objects. In our current implementation a user downloading an XML based course bucket also downloads the XML-aware tools: an applet that enables the user to edit or browse the bucket. We claim that XML provides an effective means to represent multi-level structure of a course bucket.

  2. Perceptibility curve test for digital radiographs before and after correction for attenuation and correction for attenuation and visual response.

    PubMed

    Li, G; Welander, U; Yoshiura, K; Shi, X-Q; McDavid, W D

    2003-11-01

    Two digital image processing methods, correction for X-ray attenuation and correction for attenuation and visual response, have been developed. The aim of the present study was to compare digital radiographs before and after correction for attenuation and correction for attenuation and visual response by means of a perceptibility curve test. Radiographs were exposed of an aluminium test object containing holes ranging from 0.03 mm to 0.30 mm with increments of 0.03 mm. Fourteen radiographs were exposed with the Dixi system (Planmeca Oy, Helsinki, Finland) and twelve radiographs were exposed with the F1 iOX system (Fimet Oy, Monninkylä, Finland) from low to high exposures covering the full exposure ranges of the systems. Radiographs obtained from the Dixi and F1 iOX systems were 12 bit and 8 bit images, respectively. Original radiographs were then processed for correction for attenuation and correction for attenuation and visual response. Thus, two series of radiographs were created. Ten viewers evaluated all the radiographs in the same random order under the same viewing conditions. The object detail having the lowest perceptible contrast was recorded for each observer. Perceptibility curves were plotted according to the mean of observer data. The perceptibility curves for processed radiographs obtained with the F1 iOX system are higher than those for originals in the exposure range up to the peak, where the curves are basically the same. For radiographs exposed with the Dixi system, perceptibility curves for processed radiographs are higher than those for originals for all exposures. Perceptibility curves show that for 8 bit radiographs obtained from the F1 iOX system, the contrast threshold was increased in processed radiographs up to the peak, while for 12 bit radiographs obtained with the Dixi system, the contrast threshold was increased in processed radiographs for all exposures. When comparisons were made between radiographs corrected for attenuation and corrected for attenuation and visual response, basically no differences were found. Radiographs processed for correction for attenuation and correction for attenuation and visual response may improve perception, especially for 12 bit originals.

  3. The impact of digital imaging in the field of cytopathology.

    PubMed

    Pantanowitz, Liron; Hornish, Maryanne; Goulart, Robert A

    2009-03-06

    With the introduction of digital imaging, pathology is undergoing a digital transformation. In the field of cytology, digital images are being used for telecytology, automated screening of Pap test slides, training and education (e.g. online digital atlases), and proficiency testing. To date, there has been no systematic review on the impact of digital imaging on the practice of cytopathology. This article critically addresses the emerging role of computer-assisted screening and the application of digital imaging to the field of cytology, including telecytology, virtual microscopy, and the impact of online cytology resources. The role of novel diagnostic techniques like image cytometry is also reviewed.

  4. CORBASec Used to Secure Distributed Aerospace Propulsion Simulations

    NASA Technical Reports Server (NTRS)

    Blaser, Tammy M.

    2003-01-01

    The NASA Glenn Research Center and its industry partners are developing a Common Object Request Broker (CORBA) Security (CORBASec) test bed to secure their distributed aerospace propulsion simulations. Glenn has been working with its aerospace propulsion industry partners to deploy the Numerical Propulsion System Simulation (NPSS) object-based technology. NPSS is a program focused on reducing the cost and time in developing aerospace propulsion engines. It was developed by Glenn and is being managed by the NASA Ames Research Center as the lead center reporting directly to NASA Headquarters' Aerospace Technology Enterprise. Glenn is an active domain member of the Object Management Group: an open membership, not-for-profit consortium that produces and manages computer industry specifications (i.e., CORBA) for interoperable enterprise applications. When NPSS is deployed, it will assemble a distributed aerospace propulsion simulation scenario from proprietary analytical CORBA servers and execute them with security afforded by the CORBASec implementation. The NPSS CORBASec test bed was initially developed with the TPBroker Security Service product (Hitachi Computer Products (America), Inc., Waltham, MA) using the Object Request Broker (ORB), which is based on the TPBroker Basic Object Adaptor, and using NPSS software across different firewall products. The test bed has been migrated to the Portable Object Adaptor architecture using the Hitachi Security Service product based on the VisiBroker 4.x ORB (Borland, Scotts Valley, CA) and on the Orbix 2000 ORB (Dublin, Ireland, with U.S. headquarters in Waltham, MA). Glenn, GE Aircraft Engines, and Pratt & Whitney Aircraft are the initial industry partners contributing to the NPSS CORBASec test bed. The test bed uses Security SecurID (RSA Security Inc., Bedford, MA) two-factor token-based authentication together with Hitachi Security Service digital-certificate-based authentication to validate the various NPSS users. The test bed is expected to demonstrate NPSS CORBASec-specific policy functionality, confirm adequate performance, and validate the required Internet configuration in a distributed collaborative aerospace propulsion environment.

  5. TU-AB-207-02: Testing of Body and Breast Tomosynthesis Sytems

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jones, A.

    2015-06-15

    Digital Tomosynthesis (DT) is becoming increasingly common in breast imaging and many other applications. DT is a form of computed tomography in which a limited set of projection images are acquired over a small angular range and reconstructed into a tomographic data set. The angular range and number of projections is determined both by the imaging task and equipment manufacturer. For example, in breast imaging between 9 and 25 projections are acquired over a range of 15° to 60°. It is equally valid to treat DT as the digital analog of classical tomography - for example, linear tomography. In fact,more » the name “tomosynthesis” is an acronym for “synthetic tomography”. DT shares many common features with classical tomography, including the radiographic appearance, dose, and image quality considerations. As such, both the science and practical physics of DT systems is a hybrid between CT and classical tomographic methods. This lecture will consist of three presentations that will provide a complete overview of DT, including a review of the fundamentals of DT, a discussion of testing methods for DT systems, and a description of the clinical applications of DT. While digital breast tomosynthesis will be emphasized, analogies will be drawn to body imaging to illustrate and compare tomosynthesis methods. Learning Objectives: To understand the fundamental principles behind tomosynthesis, including the determinants of image quality and dose. To learn how to test the performance of tomosynthesis imaging systems. To appreciate the uses of tomosynthesis in the clinic and the future applications of tomosynthesis.« less

  6. Designing, Prototyping and Evaluating Digital Mindfulness Applications: A Case Study of Mindful Breathing for Stress Reduction

    PubMed Central

    Hedman, Anders; Feng, Shuo; Li, Haibo; Osika, Walter

    2017-01-01

    Background During the past decade, there has been a rapid increase of interactive apps designed for health and well-being. Yet, little research has been published on developing frameworks for design and evaluation of digital mindfulness facilitating technologies. Moreover, many existing digital mindfulness applications are purely software based. There is room for further exploration and assessment of designs that make more use of physical qualities of artifacts. Objective The study aimed to develop and test a new physical digital mindfulness prototype designed for stress reduction. Methods In this case study, we designed, developed, and evaluated HU, a physical digital mindfulness prototype designed for stress reduction. In the first phase, we used vapor and light to support mindful breathing and invited 25 participants through snowball sampling to test HU. In the second phase, we added sonification. We deployed a package of probes such as photos, diaries, and cards to collect data from users who explored HU in their homes. Thereafter, we evaluated our installation using both self-assessed stress levels and heart rate (HR) and heart rate variability (HRV) measures in a pilot study, in order to measure stress resilience effects. After the experiment, we performed a semistructured interview to reflect on HU and investigate the design of digital mindfulness apps for stress reduction. Results The results of the first phase showed that 22 of 25 participants (88%) claimed vapor and light could be effective ways of promoting mindful breathing. Vapor could potentially support mindful breathing better than light (especially for mindfulness beginners). In addition, a majority of the participants mentioned sound as an alternative medium. In the second phase, we found that participants thought that HU could work well for stress reduction. We compared the effect of silent HU (using light and vapor without sound) and sonified HU on 5 participants. Subjective stress levels were statistically improved with both silent and sonified HU. The mean value of HR using silent HU was significantly lower than resting baseline and sonified HU. The mean value of root mean square of differences (RMSSD) using silent HU was significantly higher than resting baseline. We found that the differences between our objective and subjective assessments were intriguing and prompted us to investigate them further. Conclusions Our evaluation of HU indicated that HU could facilitate relaxed breathing and stress reduction. There was a difference in outcome between the physiological measures of stress and the subjective reports of stress, as well as a large intervariability among study participants. Our conclusion is that the use of stress reduction tools should be customized and that the design work of mindfulness technology for stress reduction is a complex process, which requires cooperation of designers, HCI (Human-Computer Interaction) experts and clinicians. PMID:28615157

  7. Object-based landslide detection in different geographic regions

    NASA Astrophysics Data System (ADS)

    Friedl, Barbara; Hölbling, Daniel; Eisank, Clemens; Blaschke, Thomas

    2015-04-01

    Landslides occur in almost all mountainous regions of the world and rank among the most severe natural hazards. In the last decade - according to the world disaster report 2014 published by the International Federation of Red Cross and Red Crescent Societies (IRFC) - more than 9.000 people were killed by mass movements, more than 3.2 million people were affected and the total amount of disaster estimated damage accounts to more than 1.700 million US dollars. The application of remote sensing data for mapping landslides can contribute to post-disaster reconstruction or hazard mitigation, either by providing rapid information about the spatial distribution and location of landslides in the aftermath of triggering events or by creating and updating landslide inventories. This is especially valid for remote and inaccessible areas, where information on landslides is often lacking. However, reliable methods are needed for extracting timely and relevant information about landslides from remote sensing data. In recent years, novel methods such as object-based image analysis (OBIA) have been successfully employed for semi-automated landslide mapping. Several studies revealed that OBIA frequently outperforms pixel-based approaches, as a range of image object properties (spectral, spatial, morphometric, contextual) can be exploited during the analysis. However, object-based methods are often tailored to specific study areas, and thus, the transferability to regions with different geological settings, is often limited. The present case study evaluates the transferability and applicability of an OBIA approach for landslide detection in two distinct regions, i.e. the island of Taiwan and Austria. In Taiwan, sub-areas in the Baichi catchment in the North and in the Huaguoshan catchment in the southern-central part of the island are selected; in Austria, landslide-affected sites in the Upper Salzach catchment in the federal state of Salzburg are investigated. For both regions, SPOT-5 images are combined with digital elevation models (DEM) for developing a consistent semi-automated landslide detection approach using eCognition (Trimble) software. Suitable image objects are generated by means of multiresolution segmentation. Expert knowledge, i.e. reported facts on features (e.g. mean object slope, mean NDVI) and thresholds that are commonly chosen by professionals for digital landslide mapping, is considered during classification. The applicability of a range of features is tested and the most promising parameters, i.e. features that produce appropriate results for both regions, are selected for landslide detection. However, minor adaptations of particular thresholds are necessary due to the distinct environmental conditions of the test sites. In order to reduce the number of required adjustments to a minimum, relational features and spectral indices are primarily used for classification. The obtained results are finally compared to manually digitized reference polygons and existing landslide inventories in order to quantify the applicability of the developed object-based landslide detection approach in different geographic regions.

  8. A Patient-Centered Framework for Evaluating Digital Maturity of Health Services: A Systematic Review

    PubMed Central

    Callahan, Ryan; Darzi, Ara; Mayer, Erik

    2016-01-01

    Background Digital maturity is the extent to which digital technologies are used as enablers to deliver a high-quality health service. Extensive literature exists about how to assess the components of digital maturity, but it has not been used to design a comprehensive framework for evaluation. Consequently, the measurement systems that do exist are limited to evaluating digital programs within one service or care setting, meaning that digital maturity evaluation is not accounting for the needs of patients across their care pathways. Objective The objective of our study was to identify the best methods and metrics for evaluating digital maturity and to create a novel, evidence-based tool for evaluating digital maturity across patient care pathways. Methods We systematically reviewed the literature to find the best methods and metrics for evaluating digital maturity. We searched the PubMed database for all papers relevant to digital maturity evaluation. Papers were selected if they provided insight into how to appraise digital systems within the health service and if they indicated the factors that constitute or facilitate digital maturity. Papers were analyzed to identify methodology for evaluating digital maturity and indicators of digitally mature systems. We then used the resulting information about methodology to design an evaluation framework. Following that, the indicators of digital maturity were extracted and grouped into increasing levels of maturity and operationalized as metrics within the evaluation framework. Results We identified 28 papers as relevant to evaluating digital maturity, from which we derived 5 themes. The first theme concerned general evaluation methodology for constructing the framework (7 papers). The following 4 themes were the increasing levels of digital maturity: resources and ability (6 papers), usage (7 papers), interoperability (3 papers), and impact (5 papers). The framework includes metrics for each of these levels at each stage of the typical patient care pathway. Conclusions The framework uses a patient-centric model that departs from traditional service-specific measurements and allows for novel insights into how digital programs benefit patients across the health system. Trial Registration N/A PMID:27080852

  9. Faster processing of multiple spatially-heterodyned direct to digital holograms

    DOEpatents

    Hanson, Gregory R.; Bingham, Philip R.

    2006-10-03

    Systems and methods are described for faster processing of multiple spatially-heterodyned direct to digital holograms. A method includes of obtaining multiple spatially-heterodyned holograms, includes: digitally recording a first spatially-heterodyned hologram including spatial heterodyne fringes for Fourier analysis; digitally recording a second spatially-heterodyned hologram including spatial heterodyne fringes for Fourier analysis; Fourier analyzing the recorded first spatially-heterodyned hologram by shifting a first original origin of the recorded first spatially-heterodyned hologram including spatial heterodyne fringes in Fourier space to sit on top of a spatial-heterodyne carrier frequency defined as a first angle between a first reference beam and a first, object beam; applying a first digital filter to cut off signals around the first original origin and performing an inverse Fourier transform on the result; Fourier analyzing the recorded second spatially-heterodyned hologram by shifting a second original origin of the recorded second spatially-heterodyned hologram including spatial heterodyne fringes in Fourier space to sit on top of a spatial-heterodyne carrier frequency defined as a second angle between a second reference beam and a second object beam; and applying a second digital filter to cut off signals around the second original origin and performing an inverse Fourier transform on the result, wherein digitally recording the first spatially-heterodyned hologram is completed before digitally recording the second spatially-heterodyned hologram and a single digital image includes both the first spatially-heterodyned hologram and the second spatially-heterodyned hologram.

  10. Faster processing of multiple spatially-heterodyned direct to digital holograms

    DOEpatents

    Hanson, Gregory R [Clinton, TN; Bingham, Philip R [Knoxville, TN

    2008-09-09

    Systems and methods are described for faster processing of multiple spatially-heterodyned direct to digital holograms. A method includes of obtaining multiple spatially-heterodyned holograms, includes: digitally recording a first spatially-heterodyned hologram including spatial heterodyne fringes for Fourier analysis; digitally recording a second spatially-heterodyned hologram including spatial heterodyne fringes for Fourier analysis; Fourier analyzing the recorded first spatially-heterodyned hologram by shifting a first original origin of the recorded first spatially-heterodyned hologram including spatial heterodyne fringes in Fourier space to sit on top of a spatial-heterodyne carrier frequency defined as a first angle between a first reference beam and a first object beam; applying a first digital filter to cut off signals around the first original origin and performing an inverse Fourier transform on the result; Fourier analyzing the recorded second spatially-heterodyned hologram by shifting a second original origin of the recorded second spatially-heterodyned hologram including spatial heterodyne fringes in Fourier space to sit on top of a spatial-heterodyne carrier frequency defined as a second angle between a second reference beam and a second object beam; and applying a second digital filter to cut off signals around the second original origin and performing an inverse Fourier transform on the result, wherein digitally recording the first spatially-heterodyned hologram is completed before digitally recording the second spatially-heterodyned hologram and a single digital image includes both the first spatially-heterodyned hologram and the second spatially-heterodyned hologram.

  11. Assessing a nephrology-focused YouTube channel's potential to educate health care providers.

    PubMed

    Desai, Tejas; Sanghani, Vivek; Fang, Xiangming; Christiano, Cynthia; Ferris, Maria

    2013-01-01

    YouTube has emerged as a potential teaching tool. Studies of the teaching potential of YouTube videos have not addressed health care provider (HCP) satisfaction; a necessary prerequisite for any teaching tool. We conducted a 4-month investigation to determine HCP satisfaction with a nephrology-specific YouTube channel. The Nephrology On-Demand YouTube channel was analyzed from January 1 through April 30, 2011. Sixty-minute nephrology lectures at East Carolina University were compressed into 10-minute videos and uploaded to the channel. HCPs were asked to answer a 5-point Likert questionnaire regarding the accuracy, currency, objectivity and usefulness of the digital format of the teaching videos. Means, standard deviations and 2-sided chi-square testing were performed to analyze responses. Over 80% of HCPs considered the YouTube channel to be accurate, current and objective. A similar percentage considered the digital format useful despite the compression of videos and lack of audio. The nephrology-specific YouTube channel has the potential to educate HCPs of various training backgrounds. Additional studies are required to determine if such specialty-specific channels can improve knowledge acquisition and retention.

  12. Computer-generated holograms (CGH) realization: the integration of dedicated software tool with digital slides printer

    NASA Astrophysics Data System (ADS)

    Guarnieri, Vittorio; Francini, Franco

    1997-12-01

    Last generation of digital printer is usually characterized by a spatial resolution enough high to allow the designer to realize a binary CGH directly on a transparent film avoiding photographic reduction techniques. These devices are able to produce slides or offset prints. Furthermore, services supplied by commercial printing company provide an inexpensive method to rapidly verify the validity of the design by means of a test-and-trial process. Notably, this low-cost approach appears to be suitable for a didactical environment. On the basis of these considerations, a set of software tools able to design CGH's has been developed. The guidelines inspiring the work have been the following ones: (1) ray-tracing approach, considering the object to be reproduced as source of spherical waves; (2) Optimization and speed-up of the algorithms used, in order to produce a portable code, runnable on several hardware platforms. In this paper calculation methods to obtain some fundamental geometric functions (points, lines, curves) are described. Furthermore, by the juxtaposition of these primitives functions it is possible to produce the holograms of more complex objects. Many examples of generated CGHs are presented.

  13. MEDIPIX: a VLSI chip for a GaAs pixel detector for digital radiology

    NASA Astrophysics Data System (ADS)

    Amendolia, S. R.; Bertolucci, E.; Bisogni, M. G.; Bottigli, U.; Ceccopieri, A.; Ciocci, M. A.; Conti, M.; Delogu, P.; Fantacci, M. E.; Maestro, P.; Marzulli, V.; Pernigotti, E.; Romeo, N.; Rosso, V.; Rosso, P.; Stefanini, A.; Stumbo, S.

    1999-02-01

    A GaAs pixel detector designed for digital mammography, equipped with a 36-channel single photon counting discrete read-out electronics, was tested using a test object developed for quality control purposes in mammography. Each pixel was 200×200 μm 2 large, and 200 μm deep. The choice of GaAs with respect to silicon (largely used in other applications and with a more established technique) has been made because of the much better detection efficiency at mammographic energies, combined with a very good charge collection efficiency achieved thanks to new ohmic contacts. This GaAs detector is able to perform a measurement of low-contrast details, with minimum contrast lower (nearly a factor two) than that typically achievable with standard mammographic film+screen systems in the same conditions of clinical routine. This should allow for an earlier diagnosis of breast tumour masses. Due to these encouraging results, the next step in the evolution of our imaging system based on GaAs detectors has been the development of a VLSI front-end prototype chip (MEDIPIX ) in order to cover a much larger diagnostic area. The chip reads 64×64 channels in single photon counting mode, each one 170 μm wide. Each channel contains also a test input where a signal can be simulated, injecting a known charge through a 16 f F capacitor. Fake signals have been injected via the test input measuring and equalizing minimum thresholds for all the channels. On an average, in most of the performing chips available up to now, we have found that it is possible to set a threshold as low as 1800 electrons with an RMS of 150 electrons (10 standard deviations lower than the 20 keV photon signal roughly equivalent to 4500 electrons). The detector, bump-bonded to the chip, will be tested and a ladder of detectors will be prepared to be able to scan large surface objects.

  14. 'Six sigma approach' - an objective strategy in digital assessment of postoperative air leaks: a prospective randomised study.

    PubMed

    Bertolaccini, Luca; Rizzardi, Giovanna; Filice, Mary Jo; Terzi, Alberto

    2011-05-01

    Until now, only way to report air leaks (ALs) has been with an analogue score in an inherently subjective manner. The Six Sigma quality improvement methodology is a data-driven approach applicable to evaluate the quality of the quantification method of repetitive procedures. We applied the Six Sigma concept to improve the process of AL evaluation. A digital device for AL measurement (Drentech PALM, Redax S.r.l., Mirandola (MO), Italy) was applied to 49 consecutive patients, who underwent pulmonary intervention, compared with a similar population with classical chest drainage. Data recorded were postoperative AL, chest-tube removal days, number of chest roentgenograms, hospital length of stay; device setup time, average time rating AL and patient satisfaction. Bivariable comparisons were made using the Mann-Whitney test, the χ² test and Fisher's exact test. Analysis of quality was conducted using the Six Sigma methodology. There were no significant differences regarding AL (p=0.075), although not statistically significant; there was a reduction of postoperative chest X-rays (four vs five) and of hospital length of stay (6.5 vs 7.1 days); and a marginally significant difference was found between chest-tube removal days (p=0.056). There were significant differences regarding device setup time (p=0.001), average time rating AL (p=0.001), inter-observer variability (p=0.001) and patient satisfaction (p=0.002). Six Sigma analyses revealed accurate assessment of AL. Continuous digital measurement of AL reduces degree of variability of AL score, gives more assurance for tube removal, and reports AL without the apprehension of observer error. Efficiency and effectiveness improved with the use of a digital device. We have noted that the AL curves depict actually sealing of AL. The clinical importance of AL curves requires further study. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  15. Digital cover photography for estimating leaf area index (LAI) in apple trees using a variable light extinction coefficient.

    PubMed

    Poblete-Echeverría, Carlos; Fuentes, Sigfredo; Ortega-Farias, Samuel; Gonzalez-Talice, Jaime; Yuri, Jose Antonio

    2015-01-28

    Leaf area index (LAI) is one of the key biophysical variables required for crop modeling. Direct LAI measurements are time consuming and difficult to obtain for experimental and commercial fruit orchards. Devices used to estimate LAI have shown considerable errors when compared to ground-truth or destructive measurements, requiring tedious site-specific calibrations. The objective of this study was to test the performance of a modified digital cover photography method to estimate LAI in apple trees using conventional digital photography and instantaneous measurements of incident radiation (Io) and transmitted radiation (I) through the canopy. Leaf area of 40 single apple trees were measured destructively to obtain real leaf area index (LAI(D)), which was compared with LAI estimated by the proposed digital photography method (LAI(M)). Results showed that the LAI(M) was able to estimate LAI(D) with an error of 25% using a constant light extinction coefficient (k = 0.68). However, when k was estimated using an exponential function based on the fraction of foliage cover (f(f)) derived from images, the error was reduced to 18%. Furthermore, when measurements of light intercepted by the canopy (Ic) were used as a proxy value for k, the method presented an error of only 9%. These results have shown that by using a proxy k value, estimated by Ic, helped to increase accuracy of LAI estimates using digital cover images for apple trees with different canopy sizes and under field conditions.

  16. Digital Cover Photography for Estimating Leaf Area Index (LAI) in Apple Trees Using a Variable Light Extinction Coefficient

    PubMed Central

    Poblete-Echeverría, Carlos; Fuentes, Sigfredo; Ortega-Farias, Samuel; Gonzalez-Talice, Jaime; Yuri, Jose Antonio

    2015-01-01

    Leaf area index (LAI) is one of the key biophysical variables required for crop modeling. Direct LAI measurements are time consuming and difficult to obtain for experimental and commercial fruit orchards. Devices used to estimate LAI have shown considerable errors when compared to ground-truth or destructive measurements, requiring tedious site-specific calibrations. The objective of this study was to test the performance of a modified digital cover photography method to estimate LAI in apple trees using conventional digital photography and instantaneous measurements of incident radiation (Io) and transmitted radiation (I) through the canopy. Leaf area of 40 single apple trees were measured destructively to obtain real leaf area index (LAID), which was compared with LAI estimated by the proposed digital photography method (LAIM). Results showed that the LAIM was able to estimate LAID with an error of 25% using a constant light extinction coefficient (k = 0.68). However, when k was estimated using an exponential function based on the fraction of foliage cover (ff) derived from images, the error was reduced to 18%. Furthermore, when measurements of light intercepted by the canopy (Ic) were used as a proxy value for k, the method presented an error of only 9%. These results have shown that by using a proxy k value, estimated by Ic, helped to increase accuracy of LAI estimates using digital cover images for apple trees with different canopy sizes and under field conditions. PMID:25635411

  17. 2017 Guralp Affinity Digitizer Evaluation.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Merchant, Bion J.

    Sandia National Laboratories has tested and evaluated two Guralp Affinity digitizers. The Affinity digitizers are intended to record sensor output for seismic and infrasound monitoring applications. The purpose of this digitizer evaluation is to measure the performance characteristics in such areas as power consumption, input impedance, sensitivity, full scale, self- noise, dynamic range, system noise, response, passband, and timing. The Affinity digitizers are being evaluated for potential use in the International Monitoring System (IMS) of the Comprehensive Nuclear Test-Ban-Treaty Organization (CTBTO).

  18. Rolling Shutter Effect aberration compensation in Digital Holographic Microscopy

    NASA Astrophysics Data System (ADS)

    Monaldi, Andrea C.; Romero, Gladis G.; Cabrera, Carlos M.; Blanc, Adriana V.; Alanís, Elvio E.

    2016-05-01

    Due to the sequential-readout nature of most CMOS sensors, each row of the sensor array is exposed at a different time, resulting in the so-called rolling shutter effect that induces geometric distortion to the image if the video camera or the object moves during image acquisition. Particularly in digital holograms recording, while the sensor captures progressively each row of the hologram, interferometric fringes can oscillate due to external vibrations and/or noises even when the object under study remains motionless. The sensor records each hologram row in different instants of these disturbances. As a final effect, phase information is corrupted, distorting the reconstructed holograms quality. We present a fast and simple method for compensating this effect based on image processing tools. The method is exemplified by holograms of microscopic biological static objects. Results encourage incorporating CMOS sensors over CCD in Digital Holographic Microscopy due to a better resolution and less expensive benefits.

  19. Evaluating Patient Usability of an Image-Based Mobile Health Platform for Postoperative Wound Monitoring

    PubMed Central

    Wiseman, Jason

    2016-01-01

    Background Surgical patients are increasingly using mobile health (mHealth) platforms to monitor recovery and communicate with their providers in the postdischarge period. Despite widespread enthusiasm for mHealth, few studies evaluate the usability or user experience of these platforms. Objective Our objectives were to (1) develop a novel image-based smartphone app for postdischarge surgical wound monitoring, and (2) rigorously user test it with a representative population of vascular and general surgery patients. Methods A total of 9 vascular and general surgery inpatients undertook usability testing of an internally developed smartphone app that allows patients to take digital images of their wound and answer a survey about their recovery. We followed the International Organization for Standardization (ISO) 9241-11 guidelines, focusing on effectiveness, efficiency, and user satisfaction. An accompanying training module was developed by applying tenets of adult learning. Sessions were audio-recorded, and the smartphone screen was mirrored onto a study computer. Digital image quality was evaluated by a physician panel to determine usefulness for clinical decision making. Results The mean length of time spent was 4.7 (2.1-12.8) minutes on the training session and 5.0 (1.4-16.6) minutes on app completion. 55.5% (5/9) of patients were able to complete the app independently with the most difficulty experienced in taking digital images of surgical wounds. Novice patients who were older, obese, or had groin wounds had the most difficulty. 81.8% of images were sufficient for diagnostic purposes. User satisfaction was high, with an average usability score of 83.3 out of 100. Conclusion Surgical patients can learn to use a smartphone app for postoperative wound monitoring with high user satisfaction. We identified design features and training approaches that can facilitate ease of use. This protocol illustrates an important, often overlooked, aspect of mHealth development to improve surgical care. PMID:27683059

  20. Single-camera stereo-digital image correlation with a four-mirror adapter: optimized design and validation

    NASA Astrophysics Data System (ADS)

    Yu, Liping; Pan, Bing

    2016-12-01

    A low-cost, easy-to-implement but practical single-camera stereo-digital image correlation (DIC) system using a four-mirror adapter is established for accurate shape and three-dimensional (3D) deformation measurements. The mirrors assisted pseudo-stereo imaging system can convert a single camera into two virtual cameras, which view a specimen from different angles and record the surface images of the test object onto two halves of the camera sensor. To enable deformation measurement in non-laboratory conditions or extreme high temperature environments, an active imaging optical design, combining an actively illuminated monochromatic source with a coupled band-pass optical filter, is compactly integrated to the pseudo-stereo DIC system. The optical design, basic principles and implementation procedures of the established system for 3D profile and deformation measurements are described in detail. The effectiveness and accuracy of the established system are verified by measuring the profile of a regular cylinder surface and displacements of a translated planar plate. As an application example, the established system is used to determine the tensile strains and Poisson's ratio of a composite solid propellant specimen during stress relaxation test. Since the established single-camera stereo-DIC system only needs a single camera and presents strong robustness against variations in ambient light or the thermal radiation of a hot object, it demonstrates great potential in determining transient deformation in non-laboratory or high-temperature environments with the aid of a single high-speed camera.

  1. Surface imaging microscope

    NASA Astrophysics Data System (ADS)

    Rogala, Eric W.; Bankman, Isaac N.

    2008-04-01

    The three-dimensional shapes of microscopic objects are becoming increasingly important for battlespace CBRNE sensing. Potential applications of microscopic 3D shape observations include characterization of biological weapon particles and manufacturing of micromechanical components. Aerosol signatures of stand-off lidar systems, using elastic backscatter or polarization, are dictated by the aerosol particle shapes and sizes that must be well characterized in the lab. A low-cost, fast instrument for 3D surface shape microscopy will be a valuable point sensor for biological particle sensing applications. Both the cost and imaging durations of traditional techniques such as confocal microscopes, atomic force microscopes, and electron scanning microscopes are too high. We investigated the feasibility of a low-cost, fast interferometric technique for imaging the 3D surface shape of microscopic objects at frame rates limited only by the camera in the system. The system operates at two laser wavelengths producing two fringe images collected simultaneously by a digital camera, and a specialized algorithm we developed reconstructs the surface map of the microscopic object. The current implementation assembled to test the concept and develop the new 3D reconstruction algorithm has 0.25 micron resolution in the x and y directions, and about 0.1 micron accuracy in the z direction, as tested on a microscopic glass test object manufactured with etching techniques. We describe the interferometric instrument, present the reconstruction algorithm, and discuss further development.

  2. Identification of superficial defects in reconstructed 3D objects using phase-shifting fringe projection

    NASA Astrophysics Data System (ADS)

    Madrigal, Carlos A.; Restrepo, Alejandro; Branch, John W.

    2016-09-01

    3D reconstruction of small objects is used in applications of surface analysis, forensic analysis and tissue reconstruction in medicine. In this paper, we propose a strategy for the 3D reconstruction of small objects and the identification of some superficial defects. We applied a technique of projection of structured light patterns, specifically sinusoidal fringes and an algorithm of phase unwrapping. A CMOS camera was used to capture images and a DLP digital light projector for synchronous projection of the sinusoidal pattern onto the objects. We implemented a technique based on a 2D flat pattern as calibration process, so the intrinsic and extrinsic parameters of the camera and the DLP were defined. Experimental tests were performed in samples of artificial teeth, coal particles, welding defects and surfaces tested with Vickers indentation. Areas less than 5cm were studied. The objects were reconstructed in 3D with densities of about one million points per sample. In addition, the steps of 3D description, identification of primitive, training and classification were implemented to recognize defects, such as: holes, cracks, roughness textures and bumps. We found that pattern recognition strategies are useful, when quality supervision of surfaces has enough quantities of points to evaluate the defective region, because the identification of defects in small objects is a demanding activity of the visual inspection.

  3. Oblique reconstructions in tomosynthesis. II. Super-resolution

    PubMed Central

    Acciavatti, Raymond J.; Maidment, Andrew D. A.

    2013-01-01

    Purpose: In tomosynthesis, super-resolution has been demonstrated using reconstruction planes parallel to the detector. Super-resolution allows for subpixel resolution relative to the detector. The purpose of this work is to develop an analytical model that generalizes super-resolution to oblique reconstruction planes. Methods: In a digital tomosynthesis system, a sinusoidal test object is modeled along oblique angles (i.e., “pitches”) relative to the plane of the detector in a 3D divergent-beam acquisition geometry. To investigate the potential for super-resolution, the input frequency is specified to be greater than the alias frequency of the detector. Reconstructions are evaluated in an oblique plane along the extent of the object using simple backprojection (SBP) and filtered backprojection (FBP). By comparing the amplitude of the reconstruction against the attenuation coefficient of the object at various frequencies, the modulation transfer function (MTF) is calculated to determine whether modulation is within detectable limits for super-resolution. For experimental validation of super-resolution, a goniometry stand was used to orient a bar pattern phantom along various pitches relative to the breast support in a commercial digital breast tomosynthesis system. Results: Using theoretical modeling, it is shown that a single projection image cannot resolve a sine input whose frequency exceeds the detector alias frequency. The high frequency input is correctly visualized in SBP or FBP reconstruction using a slice along the pitch of the object. The Fourier transform of this reconstructed slice is maximized at the input frequency as proof that the object is resolved. Consistent with the theoretical results, experimental images of a bar pattern phantom showed super-resolution in oblique reconstructions. At various pitches, the highest frequency with detectable modulation was determined by visual inspection of the bar patterns. The dependency of the highest detectable frequency on pitch followed the same trend as the analytical model. It was demonstrated that super-resolution is not achievable if the pitch of the object approaches 90°, corresponding to the case in which the test frequency is perpendicular to the breast support. Only low frequency objects are detectable at pitches close to 90°. Conclusions: This work provides a platform for investigating super-resolution in oblique reconstructions for tomosynthesis. In breast imaging, this study should have applications in visualizing microcalcifications and other subtle signs of cancer. PMID:24320445

  4. A PET detector prototype based on digital SiPMs and GAGG scintillators.

    PubMed

    Schneider, Florian R; Shimazoe, Kenji; Somlai-Schweiger, Ian; Ziegler, Sibylle I

    2015-02-21

    Silicon Photomultipliers (SiPM) are interesting light sensors for Positron Emission Tomography (PET). The detector signal of analog SiPMs is the total charge of all fired cells. Energy and time information have to be determined with dedicated readout electronics. Philips Digital Photon Counting has developed a SiPM with added electronics on cell level delivering a digital value of the time stamp and number of fired cells. These so called Digital Photon Counters (DPC) are fully digital devices. In this study, the feasibility of using DPCs in combination with LYSO (Lutetium Yttrium Oxyorthosilicate) and GAGG (Gadolinium Aluminum Gallium Garnet) scintillators for PET is tested. Each DPC module has 64 channels with 3.2 × 3.8775 mm(2), comprising 3200 cells each. GAGG is a recently developed scintillator (Zeff = 54, 6.63 g cm(-3), 520 nm peak emission, 46 000 photons MeV(-1), 88 ns (92%) and 230 ns (8%) decay times, non-hygroscopic, chemically and mechanically stable). Individual crystals of 2 × 2 × 6 mm(3) were coupled onto each DPC pixel. LYSO coupled to the DPC results in a coincidence time resolution (CTR) of 171 ps FWHM and an energy resolution of 12.6% FWHM at 511 keV. Using GAGG, coincidence timing is 310 ps FWHM and energy resolution is 8.5% FWHM. A PET detector prototype with 2 DPCs equipped with a GAGG array matching the pixel size (3.2 × 3.8775 × 8 mm(3)) was assembled. To emulate a ring of 10 modules, objects are rotated in the field of view. CTR of the PET is 619 ps and energy resolution is 9.2% FWHM. The iterative MLEM reconstruction is based on system matrices calculated with an analytical detector response function model. A phantom with rods of different diameters filled with (18)F was used for tomographic tests.

  5. A PET detector prototype based on digital SiPMs and GAGG scintillators

    NASA Astrophysics Data System (ADS)

    Schneider, Florian R.; Shimazoe, Kenji; Somlai-Schweiger, Ian; Ziegler, Sibylle I.

    2015-02-01

    Silicon Photomultipliers (SiPM) are interesting light sensors for Positron Emission Tomography (PET). The detector signal of analog SiPMs is the total charge of all fired cells. Energy and time information have to be determined with dedicated readout electronics. Philips Digital Photon Counting has developed a SiPM with added electronics on cell level delivering a digital value of the time stamp and number of fired cells. These so called Digital Photon Counters (DPC) are fully digital devices. In this study, the feasibility of using DPCs in combination with LYSO (Lutetium Yttrium Oxyorthosilicate) and GAGG (Gadolinium Aluminum Gallium Garnet) scintillators for PET is tested. Each DPC module has 64 channels with 3.2 × 3.8775 mm2, comprising 3200 cells each. GAGG is a recently developed scintillator (Zeff = 54, 6.63 g cm-3, 520 nm peak emission, 46 000 photons MeV-1, 88 ns (92%) and 230 ns (8%) decay times, non-hygroscopic, chemically and mechanically stable). Individual crystals of 2 × 2 × 6 mm3 were coupled onto each DPC pixel. LYSO coupled to the DPC results in a coincidence time resolution (CTR) of 171 ps FWHM and an energy resolution of 12.6% FWHM at 511 keV. Using GAGG, coincidence timing is 310 ps FWHM and energy resolution is 8.5% FWHM. A PET detector prototype with 2 DPCs equipped with a GAGG array matching the pixel size (3.2 × 3.8775 × 8 mm3) was assembled. To emulate a ring of 10 modules, objects are rotated in the field of view. CTR of the PET is 619 ps and energy resolution is 9.2% FWHM. The iterative MLEM reconstruction is based on system matrices calculated with an analytical detector response function model. A phantom with rods of different diameters filled with 18F was used for tomographic tests.

  6. Is phase measurement necessary for incoherent holographic 3D imaging?

    NASA Astrophysics Data System (ADS)

    Rosen, Joseph; Vijayakumar, A.; Rai, Mani Ratnam; Mukherjee, Saswata

    2018-02-01

    Incoherent digital holography can be used for several applications, among which are high resolution fluorescence microscopy and imaging through a scattering medium. Historically, an incoherent digital hologram has been usually recorded by self-interference systems in which both interfering beams are originated from the same observed object. The self-interference system enables to read the phase distribution of the wavefronts propagating from an object and consequently to decode the 3D location of the object points. In this presentation, we survey several cases in which 3D holographic imaging can be done without the phase information and without two-wave interference.

  7. Object-based landslide mapping on satellite images from different sensors

    NASA Astrophysics Data System (ADS)

    Hölbling, Daniel; Friedl, Barbara; Eisank, Clemens; Blaschke, Thomas

    2015-04-01

    Several studies have proven that object-based image analysis (OBIA) is a suitable approach for landslide mapping using remote sensing data. Mostly, optical satellite images are utilized in combination with digital elevation models (DEMs) for semi-automated mapping. The ability of considering spectral, spatial, morphometric and contextual features in OBIA constitutes a significant advantage over pixel-based methods, especially when analysing non-uniform natural phenomena such as landslides. However, many of the existing knowledge-based OBIA approaches for landslide mapping are rather complex and are tailored to specific data sets. These restraints lead to a lack of transferability of OBIA mapping routines. The objective of this study is to develop an object-based approach for landslide mapping that is robust against changing input data with different resolutions, i.e. optical satellite imagery from various sensors. Two study sites in Taiwan were selected for developing and testing the landslide mapping approach. One site is located around the Baolai village in the Huaguoshan catchment in the southern-central part of the island, the other one is a sub-area of the Taimali watershed in Taitung County near the south-eastern Pacific coast. Both areas are regularly affected by severe landslides and debris flows. A range of very high resolution (VHR) optical satellite images was used for the object-based mapping of landslides and for testing the transferability across different sensors and resolutions: (I) SPOT-5, (II) Formosat-2, (III) QuickBird, and (IV) WorldView-2. Additionally, a digital elevation model (DEM) with 5 m spatial resolution and its derived products (e.g. slope, plan curvature) were used for supporting the semi-automated mapping, particularly for differentiating source areas and accumulation areas according to their morphometric characteristics. A focus was put on the identification of comparatively stable parameters (e.g. relative indices), which could be transferred to the different satellite images. The presence of bare ground was assumed to be an evidence for the occurrence of landslides. For separating vegetated from non-vegetated areas the Normalized Difference Vegetation Index (NDVI) was primarily used. Each image was divided into two respective parts based on an automatically calculated NDVI threshold value in eCognition (Trimble) software by combining the homogeneity criterion of multiresolution segmentation and histogram-based methods, so that heterogeneity is increased to a maximum. Expert knowledge models, which depict features and thresholds that are usually used by experts for digital landslide mapping, were considered for refining the classification. The results were compared to the respective results from visual image interpretation (i.e. manually digitized reference polygons for each image), which were produced by an independent local expert. By that, the spatial overlaps as well as under- and over-estimated areas were identified and the performance of the approach in relation to each sensor was evaluated. The presented method can complement traditional manual mapping efforts. Moreover, it contributes to current developments for increasing the transferability of semi-automated OBIA approaches and for improving the efficiency of change detection approaches across multi-sensor imagery.

  8. Detection, Identification, Location, and Remote Sensing using SAW RFID Sensor Tags

    NASA Technical Reports Server (NTRS)

    Barton, Richard J.

    2009-01-01

    In this presentation, we will consider the problem of simultaneous detection, identification, location estimation, and remote sensing for multiple objects. In particular, we will describe the design and testing of a wireless system capable of simultaneously detecting the presence of multiple objects, identifying each object, and acquiring both a low-resolution estimate of location and a high-resolution estimate of temperature for each object based on wireless interrogation of passive surface acoustic wave (SAW) radiofrequency identification (RFID) sensor tags affixed to each object. The system is being studied for application on the lunar surface as well as for terrestrial remote sensing applications such as pre-launch monitoring and testing of spacecraft on the launch pad and monitoring of test facilities. The system utilizes a digitally beam-formed planar receiving antenna array to extend range and provide direction-of-arrival information coupled with an approximate maximum-likelihood signal processing algorithm to provide near-optimal estimation of both range and temperature. The system is capable of forming a large number of beams within the field of view and resolving the information from several tags within each beam. The combination of both spatial and waveform discrimination provides the capability to track and monitor telemetry from a large number of objects appearing simultaneously within the field of view of the receiving array. In the presentation, we will summarize the system design and illustrate several aspects of the operational characteristics and signal structure. We will examine the theoretical performance characteristics of the system and compare the theoretical results with results obtained from experiments in both controlled laboratory environments and in the field.

  9. Common path in-line holography using enhanced joint object reference digital interferometers

    PubMed Central

    Kelner, Roy; Katz, Barak; Rosen, Joseph

    2014-01-01

    Joint object reference digital interferometer (JORDI) is a recently developed system capable of recording holograms of various types [Opt. Lett. 38(22), 4719 (2013)24322115]. Presented here is a new enhanced system design that is based on the previous JORDI. While the previous JORDI has been based purely on diffractive optical elements, displayed on spatial light modulators, the present design incorporates an additional refractive objective lens, thus enabling hologram recording with improved resolution and increased system applicability. Experimental results demonstrate successful hologram recording for various types of objects, including transmissive, reflective, three-dimensional, phase and highly scattering objects. The resolution limit of the system is analyzed and experimentally validated. Finally, the suitability of JORDI for microscopic applications is verified as a microscope objective based configuration of the system is demonstrated. PMID:24663838

  10. Debating Digital Childhoods: Questions Concerning Technologies, Economies and Determinisms

    ERIC Educational Resources Information Center

    Gibbons, Andrew

    2015-01-01

    The learning child, the child that is the object of interest through modernity and into mutated modernity, in the knowledge economy, is a digital age identity of great interest. Talk about childhood and the digital age invokes a range of questions about what is happening at this time and with these technologies and that creates more or less of a…

  11. Analysis of Interactivity and Autonomy of Existing Digital Educational Resources: The Case of Life and Earth Sciences in Morocco

    ERIC Educational Resources Information Center

    Ettazarini, Said

    2017-01-01

    The educational policy in Morocco is aimed at promoting the wide use of Information and Communication Technologies in Education and the adoption of interactive and autonomous digital resources for distance teaching and self-learning. The objective of this research is to evaluate the suitability of the existing digital educational resources for…

  12. Context-Aided Tracking with Adaptive Hyperspectral Imagery

    DTIC Science & Technology

    2011-06-01

    narrow spectral bands (e). . . . . . . . . . . . . . . . . . . . . 14 ix Figure Page 2.2. An illustration of a small portion of a digital micromirror ...incorporates two light paths: imaging and spectroscopy. Each pixel is steered towards a light path indepen- dently via the digital micromirror device (DMD...With the advent of digital micromirror device (DMD) arrays (DMA), the Rochester Institute of Technology Multi-Object Spectrometer (RITMOS) [36

  13. Research study on IPS digital controller design

    NASA Technical Reports Server (NTRS)

    Kuo, B. C.; Folkerts, C.

    1976-01-01

    The performance is investigated of the simplified continuous-data model of the Instrument Pointing System (IPS). Although the ultimate objective is to study the digital model of the system, knowledge on the performance of the continuous-data model is important in the sense that the characteristics of the digital system should approach those of the continuous-data system as the sampling period approaches zero.

  14. A Novel Optical/digital Processing System for Pattern Recognition

    NASA Technical Reports Server (NTRS)

    Boone, Bradley G.; Shukla, Oodaye B.

    1993-01-01

    This paper describes two processing algorithms that can be implemented optically: the Radon transform and angular correlation. These two algorithms can be combined in one optical processor to extract all the basic geometric and amplitude features from objects embedded in video imagery. We show that the internal amplitude structure of objects is recovered by the Radon transform, which is a well-known result, but, in addition, we show simulation results that calculate angular correlation, a simple but unique algorithm that extracts object boundaries from suitably threshold images from which length, width, area, aspect ratio, and orientation can be derived. In addition to circumventing scale and rotation distortions, these simulations indicate that the features derived from the angular correlation algorithm are relatively insensitive to tracking shifts and image noise. Some optical architecture concepts, including one based on micro-optical lenslet arrays, have been developed to implement these algorithms. Simulation test and evaluation using simple synthetic object data will be described, including results of a study that uses object boundaries (derivable from angular correlation) to classify simple objects using a neural network.

  15. A high precision ultrasonic system for vibration measurements

    NASA Astrophysics Data System (ADS)

    Young, M. S.; Li, Y. C.

    1992-11-01

    A microcomputer-aided ultrasonic system that can be used to measure the vibratory displacements of an object is presented. A pair of low cost 40-kHz ultrasonic transducers is used to transmit ultrasound toward an object and receive the ultrasound reflected from the object. The relative motion of the object modulates the phase angle difference between the transmitted and received ultrasound signals. A single-chip microcomputer-based phase detector was designed to record and analyze the phase shift information which is then sent to a PC-AT microcomputer for processing. We have developed an ingenious method to reconstruct the relative motion of an object from the acquired data of the phase difference changes. A digital plotter based experiment was also designed for testing the performance of the whole system. The measured accuracy of the system in the reported experiments is within +/- 0.4 mm and the theoretical maximal measurable speed of the object is 89.6 cm/s. The main advantages of this ultrasonic vibration measurement system are high resolution, low cost, noncontact measurement, and easy installation.

  16. The relationships between pesticide metabolites and neurobehavioral test performance in the third National Health and Nutrition Examination Survey.

    PubMed

    Krieg, Edward F

    2013-01-01

    Regression analysis was used to estimate and test for relationships between urinary pesticide metabolites and neurobehavioral test performance in adults, 20 to 59 years old, participating in the third National Health and Nutrition Examination Survey. The 12 pesticide metabolites included 2 naphthols, 8 phenols, a phenoxyacetic acid, and a pyridinol. The 3 neurobehavioral tests included in the survey were simple reaction time, symbol-digit substitution, and serial digit learning. As the 2,4-dichlorophenol, 2,5-dichlorophenol, and the pentachlorophenol concentrations increased, performance on the serial digit learning test improved. As the 2,5-dichlorophenol concentration increased, performance on the symbol-digit substitution test improved. At low concentrations, the parent compounds of these metabolites may act at acetylcholine and γ-aminobutyric acid synapses in the central nervous system to improve neurobehavioral test performance.

  17. Point-of-care mobile digital microscopy and deep learning for the detection of soil-transmitted helminths and Schistosoma haematobium

    PubMed Central

    Holmström, Oscar; Linder, Nina; Ngasala, Billy; Mårtensson, Andreas; Linder, Ewert; Lundin, Mikael; Moilanen, Hannu; Suutala, Antti; Diwan, Vinod; Lundin, Johan

    2017-01-01

    ABSTRACT Background: Microscopy remains the gold standard in the diagnosis of neglected tropical diseases. As resource limited, rural areas often lack laboratory equipment and trained personnel, new diagnostic techniques are needed. Low-cost, point-of-care imaging devices show potential in the diagnosis of these diseases. Novel, digital image analysis algorithms can be utilized to automate sample analysis. Objective: Evaluation of the imaging performance of a miniature digital microscopy scanner for the diagnosis of soil-transmitted helminths and Schistosoma haematobium, and training of a deep learning-based image analysis algorithm for automated detection of soil-transmitted helminths in the captured images. Methods: A total of 13 iodine-stained stool samples containing Ascaris lumbricoides, Trichuris trichiura and hookworm eggs and 4 urine samples containing Schistosoma haematobium were digitized using a reference whole slide-scanner and the mobile microscopy scanner. Parasites in the images were identified by visual examination and by analysis with a deep learning-based image analysis algorithm in the stool samples. Results were compared between the digital and visual analysis of the images showing helminth eggs. Results: Parasite identification by visual analysis of digital slides captured with the mobile microscope was feasible for all analyzed parasites. Although the spatial resolution of the reference slide-scanner is higher, the resolution of the mobile microscope is sufficient for reliable identification and classification of all parasites studied. Digital image analysis of stool sample images captured with the mobile microscope showed high sensitivity for detection of all helminths studied (range of sensitivity = 83.3–100%) in the test set (n = 217) of manually labeled helminth eggs. Conclusions: In this proof-of-concept study, the imaging performance of a mobile, digital microscope was sufficient for visual detection of soil-transmitted helminths and Schistosoma haematobium. Furthermore, we show that deep learning-based image analysis can be utilized for the automated detection and classification of helminths in the captured images. PMID:28838305

  18. Measuring Practicing Clinicians’ Information Literacy

    PubMed Central

    Barboza, Katherine; Jensen, Ashley E.; Bennett, Katelyn J.; Sherman, Scott E.; Schwartz, Mark D.

    2017-01-01

    Summary Background As healthcare moves towards technology-driven population health management, clinicians must adopt complex digital platforms to access health information and document care. Objectives This study explored information literacy, a set of skills required to effectively navigate population health information systems, among primary care providers in one Veterans’ Affairs (VA) medical center. Methods Information literacy was assessed during an 8-month randomized trial that tested a population health (panel) management intervention. Providers were asked about their use and comfort with two VA digital tools for panel management at baseline, 16 weeks, and post-intervention. An 8-item scale (range 0-40) was used to measure information literacy (Cronbach’s a=0.84). Scores between study arms and provider types were compared using paired t-tests and ANOVAs. Associations between self-reported digital tool use and information literacy were measured via Pearson’s correlations. Results Providers showed moderate levels of information literacy (M= 27.4, SD 6.5). There were no significant differences in mean information literacy between physicians (M=26.4, SD 6.7) and nurses (M=30.5, SD 5.2, p=0.57 for difference), or between intervention (M=28.4, SD 6.5) and control groups (M=25.1, SD 6.2, p=0.12 for difference). Information literacy was correlated with higher rates of self-reported information system usage (r=0.547, p=0.001). Clinicians identified data access, accuracy, and interpretability as potential information literacy barriers. Conclusions While exploratory in nature, cautioning generalizability, the study suggests that measuring and improving clinicians’ information literacy may play a significant role in the implementation and use of digital information tools, as these tools are rapidly being deployed to enhance communication among care teams, improve health care outcomes, and reduce overall costs. PMID:28197620

  19. Symbolic magnitude processing in elementary school children: A group administered paper-and-pencil measure (SYMP Test).

    PubMed

    Brankaer, Carmen; Ghesquière, Pol; De Smedt, Bert

    2017-08-01

    The ability to compare symbolic numerical magnitudes correlates with children's concurrent and future mathematics achievement. We developed and evaluated a quick timed paper-and-pencil measure that can easily be used, for example in large-scale research, in which children have to cross out the numerically larger of two Arabic one- and two-digit numbers (SYMP Test). We investigated performance on this test in 1,588 primary school children (Grades 1-6) and examined in each grade its associations with mathematics achievement. The SYMP Test had satisfactory test-retest reliability. The SYMP Test showed significant and stable correlations with mathematics achievement for both one-digit and two-digit comparison, across all grades. This replicates the previously observed association between symbolic numerical magnitude processing and mathematics achievement, but extends it by showing that the association is observed in all grades in primary education and occurs for single- as well as multi-digit processing. Children with mathematical learning difficulties performed significantly lower on one-digit comparison and two-digit comparison in all grades. This all suggests satisfactory construct and criterion-related validity of the SYMP Test, which can be used in research, when performing large-scale (intervention) studies, and by practitioners, as screening measure to identify children at risk for mathematical difficulties or dyscalculia.

  20. 3D endoscopic pulsed digital holography

    NASA Astrophysics Data System (ADS)

    Saucedo Anaya, T.; Mendoza Santoyo, F.; Pedrini, G.; Osten, W.

    2006-06-01

    A rigid endoscope is used in pulsed digital holography to simultaneously evaluate the three orthogonal displacement components from hidden areas of a harmonically vibrating metallic cylinder. The cylinder is illuminated from three different illuminating directions. The optical path for each illumination direction is matched to its corresponding reference beam, but also in such a way that each object-reference beam pair optical path is mismatched such that they are incoherent and can be stored in a single CCD frame. As is typical in these types of interferometric arrangements, two digital holograms are needed in order to compare two different states of the cylinder. Each hologram is Fourier transformed and due to the incoherence introduced three separate spectra are readily identified, each belonging to a object-reference beam pair. On comparing by subtraction the phase obtained from the two pulsed digital holograms it is possible to gather quantitative 3D results from harmonic displacements.

  1. Convective rainfall estimation from digital GOES-1 infrared data

    NASA Technical Reports Server (NTRS)

    Sickler, G. L.; Thompson, A. H.

    1979-01-01

    An investigation was conducted to determine the feasibility of developing and objective technique for estimating convective rainfall from digital GOES-1 infrared data. The study area was a 240 km by 240 km box centered on College Station, Texas (Texas A and M University). The Scofield and Oliver (1977) rainfall estimation scheme was adapted and used with the digital geostationary satellite data. The concept of enhancement curves with respect to rainfall approximation is discussed. Raingage rainfall analyses and satellite-derived rainfall estimation analyses were compared. The correlation for the station data pairs (observed versus estimated rainfall amounts) for the convective portion of the storm was 0.92. It was demonstrated that a fairly accurate objective rainfall technique using digital geostationary infrared satellite data is feasible. The rawinsonde and some synoptic data that were used in this investigation came from NASA's Atmospheric Variability Experiment, AVE 7.

  2. Digital innovation through partnership between nature conservation organisations and academia: a qualitative impact assessment.

    PubMed

    Galán-Díaz, Carlos; Edwards, Peter; Nelson, John D; van der Wal, René

    2015-11-01

    Nature conservation organisations increasingly turn to new digital technologies to help deliver conservation objectives. This has led to collaborative forms of working with academia to spearhead digital innovation. Through in-depth interviews with three UK research-council-funded case studies, we show that by working with academics conservation organisations can receive positive and negative impacts, some of which cut across their operations. Positive impacts include new ways of engaging with audiences, improved data workflows, financial benefits, capacity building and the necessary digital infrastructure to help them influence policy. Negative impacts include the time and resources required to learn new skills and sustain new technologies, managing different organisational objectives and shifts in working practices as a result of the new technologies. Most importantly, collaboration with academics was shown to bring the opportunity of a profound change in perspectives on technologies with benefits to the partner organisations and individuals therein.

  3. Compression of computer generated phase-shifting hologram sequence using AVC and HEVC

    NASA Astrophysics Data System (ADS)

    Xing, Yafei; Pesquet-Popescu, Béatrice; Dufaux, Frederic

    2013-09-01

    With the capability of achieving twice the compression ratio of Advanced Video Coding (AVC) with similar reconstruction quality, High Efficiency Video Coding (HEVC) is expected to become the newleading technique of video coding. In order to reduce the storage and transmission burden of digital holograms, in this paper we propose to use HEVC for compressing the phase-shifting digital hologram sequences (PSDHS). By simulating phase-shifting digital holography (PSDH) interferometry, interference patterns between illuminated three dimensional( 3D) virtual objects and the stepwise phase changed reference wave are generated as digital holograms. The hologram sequences are obtained by the movement of the virtual objects and compressed by AVC and HEVC. The experimental results show that AVC and HEVC are efficient to compress PSDHS, with HEVC giving better performance. Good compression rate and reconstruction quality can be obtained with bitrate above 15000kbps.

  4. An Approach to 3d Digital Modeling of Surfaces with Poor Texture by Range Imaging Techniques. `SHAPE from Stereo' VS. `SHAPE from Silhouette' in Digitizing Jorge Oteiza's Sculptures

    NASA Astrophysics Data System (ADS)

    García Fernández, J.; Álvaro Tordesillas, A.; Barba, S.

    2015-02-01

    Despite eminent development of digital range imaging techniques, difficulties persist in the virtualization of objects with poor radiometric information, in other words, objects consisting of homogeneous colours (totally white, black, etc.), repetitive patterns, translucence, or materials with specular reflection. This is the case for much of the Jorge Oteiza's works, particularly in the sculpture collection of the Museo Fundación Jorge Oteiza (Navarra, Spain). The present study intend to analyse and asses the performance of two digital 3D-modeling methods based on imaging techniques, facing cultural heritage in singular cases, determined by radiometric characteristics as mentioned: Shape from Silhouette and Shape from Stereo. On the other hand, the text proposes the definition of a documentation workflow and presents the results of its application in the collection of sculptures created by Oteiza.

  5. Universe creation on a computer

    NASA Astrophysics Data System (ADS)

    McCabe, Gordon

    The purpose of this paper is to provide an account of the epistemology and metaphysics of universe creation on a computer. The paper begins with F.J. Tipler's argument that our experience is indistinguishable from the experience of someone embedded in a perfect computer simulation of our own universe, hence we cannot know whether or not we are part of such a computer program ourselves. Tipler's argument is treated as a special case of epistemological scepticism, in a similar vein to 'brain-in-a-vat' arguments. It is argued that Tipler's hypothesis that our universe is a program running on a digital computer in another universe, generates empirical predictions, and is therefore a falsifiable hypothesis. The computer program hypothesis is also treated as a hypothesis about what exists beyond the physical world, and is compared with Kant's metaphysics of noumena. It is argued that if our universe is a program running on a digital computer, then our universe must have compact spatial topology, and the possibilities of observationally testing this prediction are considered. The possibility of testing the computer program hypothesis with the value of the density parameter Ω0 is also analysed. The informational requirements for a computer to represent a universe exactly and completely are considered. Consequent doubt is thrown upon Tipler's claim that if a hierarchy of computer universes exists, we would not be able to know which 'level of implementation' our universe exists at. It is then argued that a digital computer simulation of a universe, or any other physical system, does not provide a realisation of that universe or system. It is argued that a digital computer simulation of a physical system is not objectively related to that physical system, and therefore cannot exist as anything else other than a physical process occurring upon the components of the computer. It is concluded that Tipler's sceptical hypothesis, and a related hypothesis from Bostrom, cannot be true: it is impossible that our own experience is indistinguishable from the experience of somebody embedded in a digital computer simulation because it is impossible for anybody to be embedded in a digital computer simulation.

  6. Focusing and depth of field in photography: application in dermatology practice.

    PubMed

    Taheri, Arash; Yentzer, Brad A; Feldman, Steven R

    2013-11-01

    Conventional photography obtains a sharp image of objects within a given 'depth of field'; objects not within the depth of field are out of focus. In recent years, digital photography revolutionized the way pictures are taken, edited, and stored. However, digital photography does not result in a deeper depth of field or better focusing. In this article, we briefly review the concept of depth of field and focus in photography as well as new technologies in this area. A deep depth of field is used to have more objects in focus; a shallow depth of field can emphasize a subject by blurring the foreground and background objects. The depth of field can be manipulated by adjusting the aperture size of the camera, with smaller apertures increasing the depth of field at the cost of lower levels of light capture. Light-field cameras are a new generation of digital cameras that offer several new features, including the ability to change the focus on any object in the image after taking the photograph. Understanding depth of field and camera technology helps dermatologists to capture their subjects in focus more efficiently. © 2013 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. High resolution near on-axis digital holography using constrained optimization approach with faster convergence

    NASA Astrophysics Data System (ADS)

    Pandiyan, Vimal Prabhu; Khare, Kedar; John, Renu

    2017-09-01

    A constrained optimization approach with faster convergence is proposed to recover the complex object field from a near on-axis digital holography (DH). We subtract the DC from the hologram after recording the object beam and reference beam intensities separately. The DC-subtracted hologram is used to recover the complex object information using a constrained optimization approach with faster convergence. The recovered complex object field is back propagated to the image plane using the Fresnel back-propagation method. The results reported in this approach provide high-resolution images compared with the conventional Fourier filtering approach and is 25% faster than the previously reported constrained optimization approach due to the subtraction of two DC terms in the cost function. We report this approach in DH and digital holographic microscopy using the U.S. Air Force resolution target as the object to retrieve the high-resolution image without DC and twin image interference. We also demonstrate the high potential of this technique in transparent microelectrode patterned on indium tin oxide-coated glass, by reconstructing a high-resolution quantitative phase microscope image. We also demonstrate this technique by imaging yeast cells.

  8. Review and comparison of non-conventional imaging systems for three-dimensional digitization of transparent objects

    NASA Astrophysics Data System (ADS)

    Mériaudeau, Fabrice; Rantoson, Rindra; Fofi, David; Stolz, Christophe

    2012-04-01

    Fashion and design greatly influence the conception of manufactured products which now exhibit complex forms and shapes. Two-dimensional quality control procedures (e.g., shape, textures, colors, and 2D geometry) are progressively being replaced by 3D inspection methods (e.g., 3D geometry, colors, and texture on the 3D shape) therefore requiring a digitization of the object surface. Three dimensional surface acquisition is a topic which has been studied to a large extent, and a significant number of techniques for acquiring 3D shapes has been proposed, leading to a wide range of commercial solutions available on the market. These systems cover a wide range from micro-scale objects such as shape from focus and shape from defocus techniques, to several meter sized objects (time of flight technique). Nevertheless, the use of such systems still encounters difficulties when dealing with non-diffuse (non Lambertian) surfaces as is the case for transparent, semi-transparent, or highly reflective materials (e.g., glass, crystals, plastics, and shiny metals). We review and compare various systems and approaches which were recently developed for 3D digitization of transparent objects.

  9. Primary Multimedia Objects and 'Educational Metadata' A Fundamental Dilemma for Developers of Multimedia Archives; Evaluation of Digital Library Impact and User Communities by Analysis of Usage Patterns; The KYVL Kentuckiana Digital Library Project: Background and Current Status; DPDx Collection.

    ERIC Educational Resources Information Center

    Shabajee, Paul; Bollen, Johan; Luce, Rick; Weig, Eric

    2002-01-01

    Includes four articles that discuss multimedia educational database systems and the use of metadata, including repurposing; the evaluation of digital library use that analyzes the retrieval habits of users; the Kentucky Virtual Library (KYVL) and digital collection project; and the collection of the Division of Parasitic Diseases, Centers for…

  10. Accuracy and eligibility of CBCT to digitize dental plaster casts.

    PubMed

    Becker, Kathrin; Schmücker, Ulf; Schwarz, Frank; Drescher, Dieter

    2018-05-01

    Software-based dental planning requires digital casts and oftentimes cone-beam computed tomography (CBCT) radiography. However, buying a dedicated model digitizing device can be expensive and might not be required. The present study aimed to assess whether digital models derived from CBCT and models digitized using a dedicated optical device are of comparable accuracy. A total of 20 plaster casts were digitized with eight CBCT and five optical model digitizers. Corresponding models were superimposed using six control points and subsequent iterative closest point matching. Median distances were calculated among all registered models. Data were pooled per scanner and model. Boxplots were generated, and the paired t test, a Friedman test, and a post-hoc Nemenyi test were employed for statistical comparison. Results were found significant at p < 0.05. All CBCT devices allowed the digitization of plaster casts, but failed to reach the accuracy of the dedicated model digitizers (p < 0.001). Median distances between CBCT and optically digitized casts were 0.064 + - 0.005 mm. Qualitative differences among the CBCT systems were detected (χ 2  = 78.07, p < 0.001), and one CBCT providing a special plaster cast digitization mode was found superior to the competitors (p < 0.05). CBCT systems failed to reach the accuracy from optical digitizers, but within the limits of the study, accuracy appeared to be sufficient for digital planning and forensic purposes. Most CBCT systems enabled digitization of plaster casts, and accuracy was found sufficient for digital planning and storage purposes.

  11. Defining event reconstruction of digital crime scenes.

    PubMed

    Carrier, Brian D; Spafford, Eugene H

    2004-11-01

    Event reconstruction plays a critical role in solving physical crimes by explaining why a piece of physical evidence has certain characteristics. With digital crimes, the current focus has been on the recognition and identification of digital evidence using an object's characteristics, but not on the identification of the events that caused the characteristics. This paper examines digital event reconstruction and proposes a process model and procedure that can be used for a digital crime scene. The model has been designed so that it can apply to physical crime scenes, can support the unique aspects of a digital crime scene, and can be implemented in software to automate part of the process. We also examine the differences between physical event reconstruction and digital event reconstruction.

  12. Go Digital! Making Physical Samples a Valued Part of the Online Record of Science

    NASA Astrophysics Data System (ADS)

    Klump, J. F.; Lehnert, K.

    2016-12-01

    Physical samples, at first glance, seem to be the opposite to the virtual world of the internet. Yet, as anything not natively digital, physical samples can have a digital representation that is accessible through the internet. Most museums and other institutions have many more objects in their collections than they could ever put on display and many samples exist outside of formal curation workflows. Nevertheless, these objects can be of importance to science, maybe because this particular fossil is a holotype that defines an extinct animal species, or it is a mineral sample that was used to derive a reference optical reflectance spectrum that is used in the interpretation of remote sensing data from satellites. As these examples show, the value of a scientific collection lies not only in its objects but also in how these objects are integrated into the record of science. Fundamental to this are, of course, catalogues of the samples held in a collection. Significant value can be added to a collection if its catalogue is web accessible, and even better if its catalogue can be harvested into disciplinary portals to aid the discovery of samples. Sample curation in the digital age, however, must go beyond simply labeling and cataloguing. In the same way that publications and datasets can now be identified and accessed over the web, steps are now being made to do the same for physical samples. Globally unique, resolvable identifiers of samples, datasets and literature can serve as nodes to link these resources together and in this way, then cross-link between scientific interpretation in the literature, data interpreted in these works, and samples from which these data were derived. These linkages must not only be recorded in the metadata but must also be machine actionable to allow integration of these digital assets into the ever growing body and richness of the scientific record. This presentation will discuss cyberinfrastructures for samples and sample curation through case studies that illustrate how the life cycle of a sample relates to other digital objects in literature and data, and how added value is generated through these linkages.

  13. A digital transducer and digital microphone using an optical technique

    NASA Astrophysics Data System (ADS)

    Ghelmansarai, F. A.

    1996-09-01

    A transducer is devised to measure pressure, displacements or angles by optical means. This transducer delivers a digital output without relying on interferometry techniques or analogue-to-digital converters. This device is based on an optical scanner and an optical detector. An inter-digital photoconductive detector (IDPC) is employed that delivers a series of pulses, whose number depends on the scan length. A pre-objective scanning configuration is used that allows for the possibility of a flat image plane. The optical scanner provides scanning of IDPC and the generated scan length is proportional to the measurand.

  14. Magnified reconstruction of digitally recorded holograms by Fresnel-Bluestein transform.

    PubMed

    Restrepo, John F; Garcia-Sucerquia, Jorge

    2010-11-20

    A method for numerical reconstruction of digitally recorded holograms with variable magnification is presented. The proposed strategy allows for smaller, equal, or larger magnification than that achieved with Fresnel transform by introducing the Bluestein substitution into the Fresnel kernel. The magnification is obtained independent of distance, wavelength, and number of pixels, which enables the method to be applied in color digital holography and metrological applications. The approach is supported by experimental and simulation results in digital holography of objects of comparable dimensions with the recording device and in the reconstruction of holograms from digital in-line holographic microscopy.

  15. Three-axis digital holographic microscopy for high speed volumetric imaging.

    PubMed

    Saglimbeni, F; Bianchi, S; Lepore, A; Di Leonardo, R

    2014-06-02

    Digital Holographic Microscopy allows to numerically retrieve three dimensional information encoded in a single 2D snapshot of the coherent superposition of a reference and a scattered beam. Since no mechanical scans are involved, holographic techniques have a superior performance in terms of achievable frame rates. Unfortunately, numerical reconstructions of scattered field by back-propagation leads to a poor axial resolution. Here we show that overlapping the three numerical reconstructions obtained by tilted red, green and blue beams results in a great improvement over the axial resolution and sectioning capabilities of holographic microscopy. A strong reduction in the coherent background noise is also observed when combining the volumetric reconstructions of the light fields at the three different wavelengths. We discuss the performance of our technique with two test objects: an array of four glass beads that are stacked along the optical axis and a freely diffusing rod shaped E.coli bacterium.

  16. MIDAS, prototype Multivariate Interactive Digital Analysis System, Phase 1. Volume 2: Diagnostic system

    NASA Technical Reports Server (NTRS)

    Kriegler, F. J.; Christenson, D.; Gordon, M.; Kistler, R.; Lampert, S.; Marshall, R.; Mclaughlin, R.

    1974-01-01

    The MIDAS System is a third-generation, fast, multispectral recognition system able to keep pace with the large quantity and high rates of data acquisition from present and projected sensors. A principal objective of the MIDAS Program is to provide a system well interfaced with the human operator and thus to obtain large overall reductions in turn-around time and significant gains in throughout. The hardware and software generated in Phase I of the over-all program are described. The system contains a mini-computer to control the various high-speed processing elements in the data path and a classifier which implements an all-digital prototype multivariate-Gaussian maximum likelihood decision algorithm operating 2 x 105 pixels/sec. Sufficient hardware was developed to perform signature extraction from computer-compatible tapes, compute classifier coefficients, control the classifier operation, and diagnose operation. Diagnostic programs used to test MIDAS' operations are presented.

  17. End-to-end learning for digital hologram reconstruction

    NASA Astrophysics Data System (ADS)

    Xu, Zhimin; Zuo, Si; Lam, Edmund Y.

    2018-02-01

    Digital holography is a well-known method to perform three-dimensional imaging by recording the light wavefront information originating from the object. Not only the intensity, but also the phase distribution of the wavefront can then be computed from the recorded hologram in the numerical reconstruction process. However, the reconstructions via the traditional methods suffer from various artifacts caused by twin-image, zero-order term, and noise from image sensors. Here we demonstrate that an end-to-end deep neural network (DNN) can learn to perform both intensity and phase recovery directly from an intensity-only hologram. We experimentally show that the artifacts can be effectively suppressed. Meanwhile, our network doesn't need any preprocessing for initialization, and is comparably fast to train and test, in comparison with the recently published learning-based method. In addition, we validate that the performance improvement can be achieved by introducing a prior on sparsity.

  18. The application of digital image analysis for blood typing: the comparison of anti-A and anti-B monoclonal antibodies activity with standard hemagglutinating sera

    NASA Astrophysics Data System (ADS)

    Medvedeva, Maria F.; Doubrovski, Valery A.

    2017-03-01

    The resolution of the acousto-optical method for blood typing was estimated experimentally by means of two types of reagents: monoclonal antibodies and standard hemagglutinating sera. The peculiarity of this work is the application of digital photo images processing by pixel analysis previously proposed by the authors. The influence of the concentrations of reagents, of blood sample, which is to be tested, as well as of the duration of the ultrasonic action on the biological object upon the resolution of acousto-optical method were investigated. The optimal experimental conditions to obtain maximum of the resolution of the acousto-optical method were found, it creates the prerequisites for a reliable blood typing. The present paper is a further step in the development of acousto-optical method for determining human blood groups.

  19. A dual-waveband dynamic IR scene projector based on DMD

    NASA Astrophysics Data System (ADS)

    Hu, Yu; Zheng, Ya-wei; Gao, Jiao-bo; Sun, Ke-feng; Li, Jun-na; Zhang, Lei; Zhang, Fang

    2016-10-01

    Infrared scene simulation system can simulate multifold objects and backgrounds to perform dynamic test and evaluate EO detecting system in the hardware in-the-loop test. The basic structure of a dual-waveband dynamic IR scene projector was introduced in the paper. The system's core device is an IR Digital Micro-mirror Device (DMD) and the radiant source is a mini-type high temperature IR plane black-body. An IR collimation optical system which transmission range includes 3-5μm and 8-12μm is designed as the projection optical system. Scene simulation software was developed with Visual C++ and Vega soft tools and a software flow chart was presented. The parameters and testing results of the system were given, and this system was applied with satisfying performance in an IR imaging simulation testing.

  20. Matrix Analysis of the Digital Divide in eHealth Services Using Awareness, Want, and Adoption Gap

    PubMed Central

    2012-01-01

    Background The digital divide usually refers to access or usage, but some studies have identified two other divides: awareness and demand (want). Given that the hierarchical stages of the innovation adoption process of a customer are interrelated, it is necessary and meaningful to analyze the digital divide in eHealth services through three main stages, namely, awareness, want, and adoption. Objective By following the three main integrated stages of the innovation diffusion theory, from the customer segment viewpoint, this study aimed to propose a new matrix analysis of the digital divide using the awareness, want, and adoption gap ratio (AWAG). I compared the digital divide among different groups. Furthermore, I conducted an empirical study on eHealth services to present the practicability of the proposed methodology. Methods Through a review and discussion of the literature, I proposed hypotheses and a new matrix analysis. To test the proposed method, 3074 Taiwanese respondents, aged 15 years and older, were surveyed by telephone. I used the stratified simple random sampling method, with sample size allocation proportioned by the population distribution of 23 cities and counties (strata). Results This study proposed the AWAG segment matrix to analyze the digital divide in eHealth services. First, awareness and want rates were divided into two levels at the middle point of 50%, and then the 2-dimensional cross of the awareness and want segment matrix was divided into four categories: opened group, desire-deficiency group, perception-deficiency group, and closed group. Second, according to the degrees of awareness and want, each category was further divided into four subcategories. I also defined four possible strategies, namely, hold, improve, evaluate, and leave, for different regions in the proposed matrix. An empirical test on two recently promoted eHealth services, the digital medical service (DMS) and the digital home care service (DHCS), was conducted. Results showed that for both eHealth services, the digital divides of awareness, want, and adoption existed across demographic variables, as well as between computer owners and nonowners, and between Internet users and nonusers. With respect to the analysis of the AWAG segment matrix for DMS, most of the segments, except for people with marriage status of Other or without computers, were positioned in the opened group. With respect to DHCS, segments were separately positioned in the opened, perception-deficiency, and closed groups. Conclusions Adoption does not closely follow people’s awareness or want, and a huge digital divide in adoption exists in DHS and DHCS. Thus, a strategy to promote adoption should be used for most demographic segments. PMID:22329958

Top