NASA Astrophysics Data System (ADS)
Evrard, Olivier; Laceby, J. Patrick; Onda, Yuichi; Wakiyama, Yoshifumi; Jaegler, Hugo; Lefèvre, Irène
2016-10-01
Fallout from the Fukushima Dai-ichi nuclear power plant accident resulted in a 3000-km2 radioactive contamination plume. Here, we model the progressive dilution of the radiocesium contamination in 327 sediment samples from two neighboring catchments with different timing of soil decontamination. Overall, we demonstrate that there has been a ~90% decrease of the contribution of upstream contaminated soils to sediment transiting the coastal plains between 2012 (median - M - contribution of 73%, mean absolute deviation - MAD - of 27%) and 2015 (M 9%, MAD 6%). The occurrence of typhoons and the progress of decontamination in different tributaries of the Niida River resulted in temporary increases in local contamination. However, the much lower contribution of upstream contaminated soils to coastal plain sediment in November 2015 demonstrates that the source of the easily erodible, contaminated material has potentially been removed by decontamination, diluted by subsoils, or eroded and transported to the Pacific Ocean.
Evrard, Olivier; Laceby, J. Patrick; Onda, Yuichi; Wakiyama, Yoshifumi; Jaegler, Hugo; Lefèvre, Irène
2016-01-01
Fallout from the Fukushima Dai-ichi nuclear power plant accident resulted in a 3000-km2 radioactive contamination plume. Here, we model the progressive dilution of the radiocesium contamination in 327 sediment samples from two neighboring catchments with different timing of soil decontamination. Overall, we demonstrate that there has been a ~90% decrease of the contribution of upstream contaminated soils to sediment transiting the coastal plains between 2012 (median – M – contribution of 73%, mean absolute deviation – MAD – of 27%) and 2015 (M 9%, MAD 6%). The occurrence of typhoons and the progress of decontamination in different tributaries of the Niida River resulted in temporary increases in local contamination. However, the much lower contribution of upstream contaminated soils to coastal plain sediment in November 2015 demonstrates that the source of the easily erodible, contaminated material has potentially been removed by decontamination, diluted by subsoils, or eroded and transported to the Pacific Ocean. PMID:27694832
Characterization of ultrafiltration of undiluted and diluted stored urine.
Ouma, J; Septien, S; Velkushanova, K; Pocock, J; Buckley, C
2016-11-01
Urine ultrafiltration (UF) was studied in terms of flux, permeability, resistance and fouling. Two types of samples were used: stored urine representing the feedstock obtained from urine diversion dry toilets; and diluted stored urine representing the feedstock obtained from urinals. Three different filtration experiment sets were adopted in this study. For the first case, pressure was set in an ascending order, i.e. from 10 to 60 kPa during filtration of stored urine. For the second case, pressure was set in a descending order, i.e. from 60 to 10 kPa for the same feed stream. The third case involved filtration of diluted urine with pressure in ascending order, i.e. from 10 to 60 kPa. The results indicated that diluted urine had higher flux than undiluted urine with maximum values of 43 and 26 L·m -2 ·h -1 respectively. Cake formation was the dominating fouling mechanism during urine filtration with a contribution of about 90% to the total hydraulic resistance. The contribution of chemically irreversible fouling was low (-2%), unless operating from high to low pressures. Indeed, irreversible fouling appeared to be greater during the experiments starting at higher pressure. Although undiluted urine had a higher fouling potential compared to diluted urine, the specific cake resistance was higher for diluted urine, probably due to a denser cake caused by lower particle sizes in that sample. The permeate obtained after urine filtration had much lower suspended solids content compared to the feedstock, with rejections up to 99%. The concentration of the ionic species remained unchanged, and 75% of the organic compounds and dissolved solids remained in the permeate. Urine UF could then be used as pre-treatment to remove suspended solids.
Drought effects on water quality in the South Platte River Basin, Colorado
Sprague, Lori A.
2005-01-01
Twenty-three stream sites representing a range of forested, agricultural, and urban land uses were sampled in the South Platte River Basin of Colorado from July through September 2002 to characterize water quality during drought conditions. With a few exceptions, dissolved ammonia, Kjeldahl nitrogen, total phosphorus, and dissolved orthophosphate concentrations were similar to seasonal historical levels in all land use areas during the drought. At some agricultural sites, decreased dilution of irrigation return flow may have contributed to higher concentrations of some nutrient species, increased primary productivity, and higher dissolved oxygen concentrations. At some urban sites, decreased dilution of base flow and wastewater treatment plant effluent may have contributed to higher dissolved nitrite-plus-nitrate concentrations, increased primary productivity, and higher dissolved oxygen concentrations. Total pesticide concentrations in urban and agricultural areas were not consistently higher or lower during the drought. At most forested sites, decreased dilution of ground water-derived calcium bicarbonate type base flow likely led to elevated pH and specific-conductance values. Water temperatures at many of the forested sites also were higher, contributing to lower dissolved oxygen concentrations during the drought.
Stability and rheology of dilute TiO2-water nanofluids
2011-01-01
The apparent wall slip (AWS) effect, accompanying the flow of colloidal dispersions in confined geometries, can be an important factor for the applications of nanofluids in heat transfer and microfluidics. In this study, a series of dilute TiO2 aqueous dispersions were prepared and tested for the possible presence of the AWS effect by means of a novel viscometric technique. The nanofluids, prepared from TiO2 rutile or anatase nanopowders by ultrasonic dispersing in water, were stabilized by adjusting the pH to the maximum zeta potential. The resulting stable nanofluid samples were dilute, below 0.7 vol.%. All the samples manifest Newtonian behavior with the fluidities almost unaffected by the presence of the dispersed phase. No case of important slip contribution was detected: the Navier slip coefficient of approximately 2 mm Pa-1 s-1 would affect the apparent fluidity data in a 100-μm gap by less than 1%. PMID:21711783
Felix, Larry Gordon; Farthing, William Earl; Irvin, James Hodges; Snyder, Todd Robert
2010-05-11
A dilution apparatus for diluting a gas sample. The apparatus includes a sample gas conduit having a sample gas inlet end and a diluted sample gas outlet end, and a sample gas flow restricting orifice disposed proximate the sample gas inlet end connected with the sample gas conduit and providing fluid communication between the exterior and the interior of the sample gas conduit. A diluted sample gas conduit is provided within the sample gas conduit having a mixing end with a mixing space inlet opening disposed proximate the sample gas inlet end, thereby forming an annular space between the sample gas conduit and the diluted sample gas conduit. The mixing end of the diluted sample gas conduit is disposed at a distance from the sample gas flow restricting orifice. A dilution gas source connected with the sample gas inlet end of the sample gas conduit is provided for introducing a dilution gas into the annular space, and a filter is provided for filtering the sample gas. The apparatus is particularly suited for diluting heated sample gases containing one or more condensable components.
Spin diffusion in the Mn2+ ion system of II-VI diluted magnetic semiconductor heterostructures
NASA Astrophysics Data System (ADS)
Maksimov, A. A.; Yakovlev, D. R.; Debus, J.; Tartakovskii, I. I.; Waag, A.; Karczewski, G.; Wojtowicz, T.; Kossut, J.; Bayer, M.
2010-07-01
The magnetization dynamics in diluted magnetic semiconductor heterostructures based on (Zn,Mn)Se and (Cd,Mn)Te were studied optically and simulated numerically. In samples with inhomogeneous magnetic ion distribution, these dynamics are contributed by spin-lattice relaxation and spin diffusion in the Mn spin system. A spin-diffusion coefficient of 7×10-8cm2/s was evaluated for Zn0.99Mn0.01Se from comparison of experiment and theory. Calculations of the exciton giant Zeeman splitting and the magnetization dynamics in ordered alloys and digitally grown parabolic quantum wells show perfect agreement with the experimental data. In both structure types, spin diffusion contributes essentially to the magnetization dynamics.
Johns, Jennifer L.; Moorhead, Kaitlin A.; Hu, Jing; Moorhead, Roberta C.
2018-01-01
Clinical pathology testing of rodents is often challenging due to insufficient sample volume. One solution in clinical veterinary and exploratory research environments is dilution of samples prior to analysis. However, published information on the impact of preanalytical sample dilution on rodent biochemical data is incomplete. The objective of this study was to evaluate the effects of preanalytical sample dilution on biochemical analysis of mouse and rat serum samples utilizing the Siemens Dimension Xpand Plus. Rats were obtained from end of study research projects. Mice were obtained from sentinel testing programs. For both, whole blood was collected via terminal cardiocentesis into empty tubes and serum was harvested. Biochemical parameters were measured on fresh and thawed frozen samples run straight and at dilution factors 2–10. Dilutions were performed manually, utilizing either ultrapure water or enzyme diluent per manufacturer recommendations. All diluted samples were generated directly from the undiluted sample. Preanalytical dilution caused clinically unacceptable bias in most analytes at dilution factors four and above. Dilution-induced bias in total calcium, creatinine, total bilirubin, and uric acid was considered unacceptable with any degree of dilution, based on the more conservative of two definitions of acceptability. Dilution often caused electrolyte values to fall below assay range precluding evaluation of bias. Dilution-induced bias occurred in most biochemical parameters to varying degrees and may render dilution unacceptable in the exploratory research and clinical veterinary environments. Additionally, differences between results obtained at different dilution factors may confound statistical comparisons in research settings. Comparison of data obtained at a single dilution factor is highly recommended. PMID:29497614
Structural transformations in diluted micellar and lamellar systems
NASA Astrophysics Data System (ADS)
Zelaya-Rincon, Blanca
The role of dilution by artificial hard water on nanostructures present in body wash samples provided by Procter and Gamble were investigated using time-resolved cryogenic transmission electron microscopy (cryo-TEM). Samples with and without perfume were examined at 10X, 20X, and 50X dilution. Micellar samples transformed to mostly unilamellar vesicles at 50X dilution, in contrast to the micelle to monomer transition seen in typical samples. At lower dilutions, a change in morphology from spherical to wormlike micelles was observed. For lamellar samples, lower dilution ratios show tightly packed multilamellar vesicles, while higher dilution ratios show more dispersed vesicles with less bilayers. Nanostructural transformations upon dilution were attributed to changes in curvature/packing parameters, which occurred due to dilution with hard water and addition of perfume. The systems experience changes in curvature in order to maintain equilibrium. Also, the addition of perfume in the lamellar samples caused an increase in the number of bilayers present in multilamellar vesicles, because of its role in increasing the packing parameter in the system.
Estimation method for serial dilution experiments.
Ben-David, Avishai; Davidson, Charles E
2014-12-01
Titration of microorganisms in infectious or environmental samples is a corner stone of quantitative microbiology. A simple method is presented to estimate the microbial counts obtained with the serial dilution technique for microorganisms that can grow on bacteriological media and develop into a colony. The number (concentration) of viable microbial organisms is estimated from a single dilution plate (assay) without a need for replicate plates. Our method selects the best agar plate with which to estimate the microbial counts, and takes into account the colony size and plate area that both contribute to the likelihood of miscounting the number of colonies on a plate. The estimate of the optimal count given by our method can be used to narrow the search for the best (optimal) dilution plate and saves time. The required inputs are the plate size, the microbial colony size, and the serial dilution factors. The proposed approach shows relative accuracy well within ±0.1log10 from data produced by computer simulations. The method maintains this accuracy even in the presence of dilution errors of up to 10% (for both the aliquot and diluent volumes), microbial counts between 10(4) and 10(12) colony-forming units, dilution ratios from 2 to 100, and plate size to colony size ratios between 6.25 to 200. Published by Elsevier B.V.
Pickard, Stephanie; Becker, Irina; Merz, Karl-Heinz; Richling, Elke
2013-07-03
A stable isotope dilution analysis based on gas chromatography-mass spectrometry analysis (SIDA-GC-MS) was developed for the quantitative analysis of 12 alkylpyrazines found in commercially available coffee samples. These compounds contribute to coffee flavor. The accuracy of this method was tested by analyzing model mixtures of alkylpyrazines. Comparisons of alkylpyrazine-concentrations suggested that water as extraction solvent was superior to dichloromethane. The distribution patterns of alkylpyrazines in different roasted coffees were quite similar. The most abundant alkylpyrazine in each coffee sample was 2-methylpyrazine, followed by 2,6-dimethylpyrazine, 2,5-dimethylpyrazine, 2-ethylpyrazine, 2-ethyl-6-methylpyrazine, 2-ethyl-5-methylpyrazine, and 2,3,5-trimethylpyrazine, respectively. Among the alkylpyrazines tested, 2,3-dimethylpyrazine, 2-ethyl-3-methylpyrazine, 2-ethyl-3,6-dimethylpyrazine, and 2-ethyl-3,5-dimethylpyrazine revealed the lowest concentrations in roasted coffee. By the use of isotope dilution analysis, the total concentrations of alkylpyrazines in commercially available ground coffee ranged between 82.1 and 211.6 mg/kg, respectively. Decaffeinated coffee samples were found to contain lower amounts of alkylpyrazines than regular coffee samples by a factor of 0.3-0.7, which might be a result of the decaffeination procedure.
Müller, M; Heumann, K G
2000-09-01
An isotope dilution inductively coupled plasma quadrupole mass spectrometric (ID-ICP-QMS) method was developed for the simultaneous determination of the platinum group elements Pt, Pd, Ru, and Ir in environmental samples. Spike solutions, enriched with the isotopes 194Pt, 108Pd, 99Ru, and 191Ir, were used for the isotope dilution step. Interfering elements were eliminated by chromatographic separation using an anion-exchange resin. Samples were dissolved with aqua regia in a high pressure asher. Additional dissolution of possible silicate portions by hydrofluoric acid was usually not necessary. Detection limits of 0.15 ng x g(-1), 0.075 ng x g(-1), and 0.015 ng x g(-1) were achieved for Pt, Pd, Ru, and Ir, respectively, using sample weights of only 0.2 g. The reliability of the ID-ICP-QMS method was demonstrated by analyzing a Canadian geological reference material and by participating in an interlaboratory study for the determination of platinum and palladium in a homogenized road dust sample. Surface soil, sampled at different distances from a highway, showed concentrations in the range of 0.1-87 ng x g(-1). An exponential decrease of the platinum and palladium concentration with increasing distance and a small anthropogenic contribution to the natural background concentration of ruthenium and iridium was found in these samples.
Thomas, Pious; Sekhar, Aparna C; Upreti, Reshmi; Mujawar, Mohammad M; Pasha, Sadiq S
2015-12-01
We propose a simple technique for bacterial and yeast cfu estimations from diverse samples with no prior idea of viable counts, designated as single plate-serial dilution spotting (SP-SDS) with the prime recommendation of sample anchoring (10 0 stocks). For pure cultures, serial dilutions were prepared from 0.1 OD (10 0 ) stock and 20 μl aliquots of six dilutions (10 1 -10 6 ) were applied as 10-15 micro-drops in six sectors over agar-gelled medium in 9-cm plates. For liquid samples 10 0 -10 5 dilutions, and for colloidal suspensions and solid samples (10% w/v), 10 1 -10 6 dilutions were used. Following incubation, at least one dilution level yielded 6-60 cfu per sector comparable to the standard method involving 100 μl samples. Tested on diverse bacteria, composite samples and Saccharomyces cerevisiae , SP-SDS offered wider applicability over alternative methods like drop-plating and track-dilution for cfu estimation, single colony isolation and culture purity testing, particularly suiting low resource settings.
Wu, Shu Juan; Hayden, Joshua A
2018-02-15
Sandwich immunoassays offer advantages in the clinical laboratory but can yield erroneously low results due to hook (prozone) effect, especially with analytes whose concentrations span several orders of magnitude such as ferritin. This study investigated a new approach to reduce the likelihood of hook effect in ferritin immunoassays by performing upfront, five-fold dilutions of all samples for ferritin analysis. The impact of this change on turnaround time and costs were also investigated. Ferritin concentrations were analysed in routine clinical practice with and without upfront dilutions on Siemens Centaur® XP (Siemens Healthineers, Erlang, Germany) immunoanalysers. In addition, one month of baseline data (1026 results) were collected prior to implementing upfront dilutions and one month of data (1033 results) were collected after implementation. Without upfront dilutions, hook effect was observed in samples with ferritin concentrations as low as 86,028 µg/L. With upfront dilutions, samples with ferritin concentrations as high as 126,050 µg/L yielded values greater than the measurement interval and would have been diluted until an accurate value was obtained. The implementation of upfront dilution of ferritin samples led to a decrease in turnaround time from a median of 2 hours and 3 minutes to 1 hour and 18 minutes (P = 0.002). Implementation of upfront dilutions of all ferritin samples reduced the possibility of hook effect, improved turnaround time and saved the cost of performing additional dilutions.
Pereira, Gregório
2017-01-01
Background: Age-associated skin laxity contributes to worsening of cellulite appearance. This study evaluated the effects of microfocused ultrasound with visualization (MFU-V; Ultherapy) in combination with diluted calcium hydroxylapatite (CaHA; Radiesse) on cellulite appearance and on neocollagenesis. Methods: Twenty women (18–55 years old) with skin laxity and moderate-to-severe cellulite on the buttocks and thighs were retrospectively enrolled. MFU-V was applied using 4 and 7 MHz transducers (25 lines/transducer/site) and immediately followed by subdermal CaHA injection (1 ml/buttock or thigh). Photographs at baseline and 90 days were assessed by 2 independent, blinded evaluators using a 5-item cellulite severity scale. One subject scheduled for thighplasty received treatment with 6 different CaHA dilutions (0.3 ml/5 cm2) followed by MFU-V. Tissue specimens from each dilution site were examined under polarized light microscopy to assess neocollagenesis. Results: Both evaluators reported statistically significant improvements compared with baseline for each item on the cellulite severity scale (P < 0.001) with a 4.5-point improvement in mean overall score (P < 0.001) after a single MFU-V/CaHA treatment. At 90 days, histologic analysis showed peak neocollagenesis in samples treated with the 1:1 dilution, whether with CaHA alone or in combination with MFU-V. The highest conversion of collagen type III into collagen type I at month 3 occurred in samples injected with 1:1 and 1:0.6 CaHA dilutions without subsequent MFU-V treatment. Both procedures were well tolerated, and subject satisfaction was high. Conclusions: Combination treatment with MFU-V and diluted CaHA is effective for improving skin laxity and the appearance of cellulite on the buttocks and upper thighs. PMID:28831339
40 CFR 89.424 - Dilute emission sampling calculations.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 20 2010-07-01 2010-07-01 false Dilute emission sampling calculations... Emission Test Procedures § 89.424 Dilute emission sampling calculations. (a) The final reported emission... concentration. For cases where exhaust sampling of CO2 is not performed, the following approximation is...
40 CFR 89.424 - Dilute emission sampling calculations.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 20 2011-07-01 2011-07-01 false Dilute emission sampling calculations... Emission Test Procedures § 89.424 Dilute emission sampling calculations. (a) The final reported emission... concentration. For cases where exhaust sampling of CO2 is not performed, the following approximation is...
2017-10-01
activin A Quantikine ELISA (R&D Systems) following the manufacturer’s instructions. All samples were run in duplicates after a 1:4 dilution in PBS. Ang-1...Nearest person month(s) worked: 8.4 months Contribution to Project: Dr. Wilson coordinated the experiments and performed imaging, chromatography, ELISA
Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases
NASA Technical Reports Server (NTRS)
Barile, R. G.; Hodge, T. R.; Meneghelli, B. J.; Gursky, R.; Lueck, D. E.
1997-01-01
Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7,500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4-inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm ppm MMH, and diluted vapor samples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sampling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2, and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4 into the ranges of existing TLV detectors.
Avian plasma chemistry analysis using diluted samples.
Waldoch, Jennifer; Wack, Raymund; Christopher, Mary
2009-12-01
Clinical chemistry tests are essential for the diagnosis and monitoring of disease in birds. The small volume of blood that can be obtained from many avian species limits the use of routine in-house chemistry analyzers. The aim of this study was to examine the accuracy and precision of avian plasma chemistry values obtained by use of a benchtop analyzer in samples diluted with sterile water, as compared with undiluted samples. Whole blood samples were collected from 13 clinically healthy thick-billed parrots (Rhynchopsitta pachyrhyncha). The samples were placed in lithium heparin tubes and centrifuged and the plasma decanted. One aliquot was analyzed immediately using a VetScan benchtop analyzer with an avian-reptile-specific rotor that included 12 analytes. The remainder of the plasma was divided into two aliquots and stored at -80 degrees C until analysis. One of these aliquots was diluted 1:1, 1:1.5, 1:2, and 1:2.5 with sterile water to give final dilutions of 1:2, 1:2.5, 1:3, and 1:3.5, respectively. The other aliquot was pooled with the 12 other samples to create a plasma pool. The undiluted plasma pool and two final dilutions (1:2 and 1:3) of the pooled plasma were analyzed in replicate (n = 20) to determine intra- and interassay imprecision. Each dilution was analyzed using the avian-reptile rotor and the results multiplied by the appropriate dilution factor to obtain the final result. Significant differences were observed in clinical chemistry results obtained from diluted plasma samples for all analytes except aspartate aminotransferase, creatine kinase, and glucose. Uric acid concentration was not significantly different at dilutions of up to 1:3. Bile acids, globulins, and sodium concentrations were below the limit of detection in all diluted samples and were not statistically analyzed. Based on these results, dilution with sterile water is not recommended for biochemical analysis of avian plasma using the VetScan benchtop analyzer.
Mojtahedi, Mitra; Fouquier d'Hérouël, Aymeric; Huang, Sui
2014-01-01
Digital PCR (dPCR) exploits limiting dilution of a template into an array of PCR reactions. From this array the number of reactions that contain at least one (as opposed to zero) initial template is determined, allowing inferring the original template concentration. Here we present a novel protocol to efficiently infer the concentration of a sample and its optimal dilution for dPCR from few targeted qPCR assays. By taking advantage of the real-time amplification feature of qPCR as opposed to relying on endpoint PCR assessment as in standard dPCR prior knowledge of template concentration is not necessary. This eliminates the need for serial dilutions in a separate titration and reduces the number of necessary reactions. We describe the theory underlying our approach and discuss experimental moments that contribute to uncertainty. We present data from a controlled experiment where the initial template concentration is known as proof of principle and apply our method on directly monitoring transcript level change during cell differentiation as well as gauging amplicon numbers in cDNA samples after pre-amplification. © The Author(s) 2014. Published by Oxford University Press on behalf of Nucleic Acids Research.
Sample Diluter for Detecting Hypergolic Propellants and Other Toxic or Hazardous Gases
NASA Technical Reports Server (NTRS)
Barile, R. G.; Hodge, T. R.; Meneghelli, B. J.; Gursky, R.; Lueck, D. E.
1997-01-01
Hardware was developed to dilute vapor samples of purged hypergolic propellants (with air) into the range of existing instruments for detection of such toxic vapors. Since these detectors are normally used to monitor at the threshold limit value (TLV), most do not have quantitative capability at percent levels which relate to lower explosion limit (LEL) and fire hazards. For example, the upper limits of Energetic Sciences (ESI) 6000 series detectors used at KSC are 200 parts per million (ppm) for monomethyl hydrazine (MMH) and 500 ppm for nitrogen dioxide (NO2) arising from decomposition of nitrogen tetroxide (N2O4). Orbiter Processing Facility (OPF) personnel servicing Shuttle thrusters need to measure up to 250 ppm MMH and 7500 ppm NO2 with portable, intrinsically safe instruments. Our objective was to quickly fabricate a sample diluter out of existing materials as a temporary measure while other parallel efforts were conducted to provide a commercial or in-house-developed instrument to detect high propellant levels. A 3 to 1 diluter would bring 500 ppm MMH into the range of the existing fuel ESI, and a 30 to 1 diluter would do the same for NO2. In this way, familiar equipment already available would be used, resulting in minimal paperwork, safety, and training impacts and low cost. An MMH vapor sample-diluter was constructed from a 1/4-inch Kynar tee, along with specially designed lengths of sample and dilution tubing. The sample line was 3 feet of Bev-A-Line 4, 1/4 inch tube leading to the straight run of the tee. The side run of the tee had a 17-inch length of Bev-A-Line 4, 1/4-inch tube, for nominal 3 to 1 dilution. A gas sample bag was prepared and assayed at 113 ppm MMH, and diluted vapor sarnples were assayed at 39.5 ppm, or a measured dilution of 2.9 to 1. For NO2, a 316 stainless steel (SS) 1/8-inch tee with 49.5 inches of coiled, 1/8-inch outside diameter (OD) 316 SS tubing was used as the sarnpling end of the dilution system. The side run of the tee was open. The measured dilution ratio, based on the input value of 6,480 ppm NO2 and the average output value of 233 ppm, was 28 to 1. Thus, sample-diluters were successful in diluting concentrated hypergolic propellant vapors, both MMH and N2O4, into the ranges of existing TLV detectors.
Just add water: Accuracy of analysis of diluted human milk samples using mid-infrared spectroscopy.
Smith, R W; Adamkin, D H; Farris, A; Radmacher, P G
2017-01-01
To determine the maximum dilution of human milk (HM) that yields reliable results for protein, fat and lactose when analyzed by mid-infrared spectroscopy. De-identified samples of frozen HM were obtained. Milk was thawed and warmed (40°C) prior to analysis. Undiluted (native) HM was analyzed by mid-infrared spectroscopy for macronutrient composition: total protein (P), fat (F), carbohydrate (C); Energy (E) was calculated from the macronutrient results. Subsequent analyses were done with 1 : 2, 1 : 3, 1 : 5 and 1 : 10 dilutions of each sample with distilled water. Additional samples were sent to a certified lab for external validation. Quantitatively, F and P showed statistically significant but clinically non-critical differences in 1 : 2 and 1 : 3 dilutions. Differences at higher dilutions were statistically significant and deviated from native values enough to render those dilutions unreliable. External validation studies also showed statistically significant but clinically unimportant differences at 1 : 2 and 1 : 3 dilutions. The Calais Human Milk Analyzer can be used with HM samples diluted 1 : 2 and 1 : 3 and return results within 5% of values from undiluted HM. At a 1 : 5 or 1 : 10 dilution, however, results vary as much as 10%, especially with P and F. At the 1 : 2 and 1 : 3 dilutions these differences appear to be insignificant in the context of nutritional management. However, the accuracy and reliability of the 1 : 5 and 1 : 10 dilutions are questionable.
Bulk viscosity of molecular fluids
NASA Astrophysics Data System (ADS)
Jaeger, Frederike; Matar, Omar K.; Müller, Erich A.
2018-05-01
The bulk viscosity of molecular models of gases and liquids is determined by molecular simulations as a combination of a dilute gas contribution, arising due to the relaxation of internal degrees of freedom, and a configurational contribution, due to the presence of intermolecular interactions. The dilute gas contribution is evaluated using experimental data for the relaxation times of vibrational and rotational degrees of freedom. The configurational part is calculated using Green-Kubo relations for the fluctuations of the pressure tensor obtained from equilibrium microcanonical molecular dynamics simulations. As a benchmark, the Lennard-Jones fluid is studied. Both atomistic and coarse-grained force fields for water, CO2, and n-decane are considered and tested for their accuracy, and where possible, compared to experimental data. The dilute gas contribution to the bulk viscosity is seen to be significant only in the cases when intramolecular relaxation times are in the μs range, and for low vibrational wave numbers (<1000 cm-1); This explains the abnormally high values of bulk viscosity reported for CO2. In all other cases studied, the dilute gas contribution is negligible and the configurational contribution dominates the overall behavior. In particular, the configurational term is responsible for the enhancement of the bulk viscosity near the critical point.
Brunsch, Andrea F; Ter Laak, Thomas L; Rijnaarts, Huub; Christoffels, Ekkehard
2018-04-01
A study was conducted in which the effluent at four small to medium sized sewage treatment plants (STP) in North Rhine-Westphalia, Germany was monitored for three pharmaceutical compounds (carbamazepine, diclofenac, metoprolol) over a period of four years. Grab sampling and auto sampling campaigns were accomplished with respect to various weather conditions in the catchment area. Flow volumes and hydraulic retention times (HRT) from various sampling dates which provide information on processes causing emission changes were additionally taken into account. Monitoring results showed that concentration scattering in the effluent is related to HRT in the sewage treatment plants. Dilution effects following rain events in the catchment area were analysed for the three investigated substances. Short-term emission changes explained by dilution only could be well determined by the mathematical relation between discharge and concentration, and for carbamazepine to be solely determined by the dilution effects at all HRTs. For metoprolol, a clear decrease in concentrations was observed at HRTs above 80 h, and a significant contribution of biodegradation was supported by independent biodegradation tests. For three out of the four STPs, a decrease in concentrations of diclofenac was observed at hydraulic retention times above 80 h, indicating removal, whereas the relationship between concentration and HRT of the other STP could be explained by dilution only. The study shows that emissions can vary with weather conditions, hampering the assessment of emissions and estimation of concentrations in surface waters from generic removal rates only. Furthermore, it illustrates the importance of HRT of rather stable substances in wastewater treatment. Copyright © 2018 Elsevier Ltd. All rights reserved.
Fan, Wenlai; Qian, Michael C
2005-10-05
The aroma compounds of young and aged Chinese "Yanghe Daqu" liquor samples were extracted by solid phase microextraction (SPME) and analyzed by gas chromatography (GC)-olfactometry dilution analysis. The original liquor samples were diluted with deionized water to give a final alcohol content of 14% (v/v). The samples were stepwise diluted (1:1) with 14% (by volume) ethanol-water solution and then extracted by headspace SPME. The samples were preequilibrated at 50 degrees C for 15 min and extracted with stirring at the same temperature for 30 min prior to injection into GC. The aroma compounds were identified by both GC-MS and GC-olfactometry using DB-Wax and DB-5 columns. The results suggested that esters were the major contributors to Yanghe Daqu liquor aroma. Ethyl hexanoate, ethyl butanoate, and ethyl pentanoate had very high flavor dilution values in both young and aged liquors (FD > 8192). Methyl hexanoate, ethyl heptanoate, ethyl benzoate, and butyl hexanoate could also be very important because of their high flavor dilution values (FD > or = 256). Moreover, two acetals, 1,1-diethoxyethane and 1,1-diethoxy-3-methylbutane, also were shown high flavor dilution values in Yanghe Daqu liquors (FD > or = 256). Other aroma compounds having moderate flavor dilution values included acetaldehyde, 3-methylbutanol, and 2-pentanol (FD > or = 32). Comparing young and aged liquors, the aroma profiles were similar, but the aroma compounds in the aged sample had higher flavor dilution values than in the young ones.
Production and distribution of dilute species in semiconducting materials
James, Ralph B.; Camarda, Giuseppe; Bolotnikov, Aleksey E.; Hossain, Anwar; Yang, Ge; Kim, Kihyun
2016-09-06
Technologies are described effective to implement systems and methods of producing a material. The methods comprise receiving a tertiary semiconductor sample with a dilute species. The sample has two ends. The first end of the sample includes a first concentration of the dilute species lower than a second concentration of the dilute species in the second end of the sample. The method further comprises heating the sample in a chamber. The chamber has a first zone and a second zone. The first zone having a first temperature higher than a second temperature in the second zone. The sample is orientated such that the first end is in the first zone and the second end is in the second zone.
Assay Dilution Factors Confound Measures of Total Antioxidant Capacity in Polyphenol-Rich Juices
Bolling, Bradley W.; Chen, Ya-Yen; Kamil, Alison G.; Chen, C-Y. Oliver
2016-01-01
The extent to which sample dilution factor (DF) affects total antioxidant capacity (TAC) values is poorly understood. Thus, we examined the impact of DF on the ORAC, FRAP, DPPH, and total phenols (TP) assays using pomegranate juice (PJ), grape juice (GJ), selected flavonoids, ascorbic acid, and ellagic acid. For ORAC, GJ was comparable to PJ at DF 750, but at DF 2000, the ORAC value of GJ was 40% more than PJ. Increasing DF increased GJ and PJ, DPPH, TP, and FRAP values 11% and 14%, respectively. Increased test concentrations of quercetin and catechin resulted in 51% and 126% greater ORAC values, but decreased naringenin by 68%. Flavonoids, but not ellagic acid or ascorbic acid, may contribute to the dilution effect on the variation of final TAC values. Thus, reporting TAC or TP using a single DF may introduce uncertainty about the confidence of TAC assay values, especially when comparing different juices. These results underscore the importance of using compatible test standards for reporting TAC values. PMID:22251245
Unanticipated error in HbA(1c) measurement on the HLC-723 G7 analyzer.
van den Ouweland, Johannes M W; de Keijzer, Marinus H; van Daal, Henny
2010-04-01
Investigation of falsely elevated HbA(1c) measurements on the HLC-723 G7 analyser. Comparison of HbA(1c) in blood samples that were diluted either in hemolysis reagent or water. HbA(1c) results became falsely elevated when samples were diluted in hemolysis reagent, but not in water. QC-procedures failed to detect this error as calibrator and QC samples were manually diluted in water, according to manufacturer's instructions, whereas patient samples were automatically diluted using hemolysing reagent. After replacement of the instruments' sample-loop and rotor seal comparable HbA(1c) results were obtained, irrespective of dilution with hemolysing reagent or water. This case illustrates the importance of treating calibrator and QC materials similar to routine patient samples in order to prevent unnoticed drift in patient HbA(1c) results. Copyright 2010 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Farthing, William Earl [Pinson, AL; Felix, Larry Gordon [Pelham, AL; Snyder, Todd Robert [Birmingham, AL
2008-02-12
An apparatus and method for diluting and cooling that is extracted from high temperature and/or high pressure industrial processes. Through a feedback process, a specialized, CFD-modeled dilution cooler is employed along with real-time estimations of the point at which condensation will occur within the dilution cooler to define a level of dilution and diluted gas temperature that results in a gas that can be conveyed to standard gas analyzers that contains no condensed hydrocarbon compounds or condensed moisture.
Farthing, William Earl; Felix, Larry Gordon; Snyder, Todd Robert
2009-12-15
An apparatus and method for diluting and cooling that is extracted from high temperature and/or high pressure industrial processes. Through a feedback process, a specialized, CFD-modeled dilution cooler is employed along with real-time estimations of the point at which condensation will occur within the dilution cooler to define a level of dilution and diluted gas temperature that results in a gas that can be conveyed to standard gas analyzers that contains no condensed hydrocarbon compounds or condensed moisture.
Correlation Between Iron and alpha and pi Glutathione-S-Transferase Levels in Humans
2012-09-01
assays were performed as described in the Biotrin High Sensitivity Alpha GST EIA kit protocol. First, serum samples were diluted 1:10 with wash solution...immunosorbent assays were performed as described in the Biotrin Pi GST EIA kit protocol. First, plasma samples were diluted 1:5 with sample diluent...immunosorbent assays were performed as described in the AssayMax Human Transferrin ELISA kit protocol. First, serum samples were diluted 1:2000 with MIX
Feng, Yunzi; Cai, Yu; Sun-Waterhouse, Dongxiao; Cui, Chun; Su, Guowan; Lin, Lianzhu; Zhao, Mouming
2015-11-15
Aroma extract dilution analysis (AEDA) is widely used for the screening of aroma-active compounds in gas chromatography-olfactometry (GC-O). In this study, three aroma dilution methods, (I) using different test sample volumes, (II) diluting samples, and (III) adjusting the GC injector split ratio, were compared for the analysis of volatiles by using HS-SPME-AEDA. Results showed that adjusting the GC injector split ratio (III) was the most desirable approach, based on the linearity relationships between Ln (normalised peak area) and Ln (normalised flavour dilution factors). Thereafter this dilution method was applied in the analysis of aroma-active compounds in Japanese soy sauce and 36 key odorants were found in this study. The most intense aroma-active components in Japanese soy sauce were: ethyl 2-methylpropanoate, ethyl 2-methylbutanoate, ethyl 3-methylbutanoate, ethyl 4-methylpentanoate, 3-(methylthio)propanal, 1-octen-3-ol, 2-methoxyphenol, 4-ethyl-2-methoxyphenol, 2-methoxy-4-vinylphenol, 2-phenylethanol, and 4-hydroxy-5-ethyl-2-methyl-3(2H)-furanone. Copyright © 2015. Published by Elsevier Ltd.
Measurement of biochemical oxygen demand of the leachates.
Fulazzaky, Mohamad Ali
2013-06-01
Biochemical oxygen demand (BOD) of the leachates originally from the different types of landfill sites was studied based on the data measured using the two manometric methods. The measurements of BOD using the dilution method were carried out to assess the typical physicochemical and biological characteristics of the leachates together with some other parameters. The linear regression analysis was used to predict rate constants for biochemical reactions and ultimate BOD values of the different leachates. The rate of a biochemical reaction implicated in microbial biodegradation of pollutants depends on the leachate characteristics, mass of contaminant in the leachate, and nature of the leachate. Character of leachate samples for BOD analysis of using the different methods may differ significantly during the experimental period, resulting in different BOD values. This work intends to verify effect of the different dilutions for the manometric method tests on the BOD concentrations of the leachate samples to contribute to the assessment of reaction rate and microbial consumption of oxygen.
40 CFR 1065.245 - Sample flow meter for batch sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Flow-Related Measurements § 1065.245... difference between a diluted exhaust sample flow meter and a dilution air meter to calculate raw exhaust flow...
40 CFR 1065.245 - Sample flow meter for batch sampling.
Code of Federal Regulations, 2014 CFR
2014-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Flow-Related Measurements § 1065.245... difference between a diluted exhaust sample flow meter and a dilution air meter to calculate raw exhaust flow...
40 CFR 1065.245 - Sample flow meter for batch sampling.
Code of Federal Regulations, 2013 CFR
2013-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Flow-Related Measurements § 1065.245... difference between a diluted exhaust sample flow meter and a dilution air meter to calculate raw exhaust flow...
40 CFR 1065.245 - Sample flow meter for batch sampling.
Code of Federal Regulations, 2012 CFR
2012-07-01
... POLLUTION CONTROLS ENGINE-TESTING PROCEDURES Measurement Instruments Flow-Related Measurements § 1065.245... difference between a diluted exhaust sample flow meter and a dilution air meter to calculate raw exhaust flow...
Shanks, Leslie; Siddiqui, M Ruby; Abebe, Almaz; Piriou, Erwan; Pearce, Neil; Ariti, Cono; Masiga, Johnson; Muluneh, Libsework; Wazome, Joseph; Ritmeijer, Koert; Klarkowski, Derryck
2015-05-14
Current WHO testing guidelines for resource limited settings diagnose HIV on the basis of screening tests without a confirmation test due to cost constraints. This leads to a potential risk of false positive HIV diagnosis. In this paper, we evaluate the dilution test, a novel method for confirmation testing, which is simple, rapid, and low cost. The principle of the dilution test is to alter the sensitivity of a rapid diagnostic test (RDT) by dilution of the sample, in order to screen out the cross reacting antibodies responsible for falsely positive RDT results. Participants were recruited from two testing centres in Ethiopia where a tiebreaker algorithm using 3 different RDTs in series is used to diagnose HIV. All samples positive on the initial screening RDT and every 10th negative sample underwent testing with the gold standard and dilution test. Dilution testing was performed using Determine™ rapid diagnostic test at 6 different dilutions. Results were compared to the gold standard of Western Blot; where Western Blot was indeterminate, PCR testing determined the final result. 2895 samples were recruited to the study. 247 were positive for a prevalence of 8.5 % (247/2895). A total of 495 samples underwent dilution testing. The RDT diagnostic algorithm misclassified 18 samples as positive. Dilution at the level of 1/160 was able to correctly identify all these 18 false positives, but at a cost of a single false negative result (sensitivity 99.6 %, 95 % CI 97.8-100; specificity 100 %, 95 % CI: 98.5-100). Concordance between the gold standard and the 1/160 dilution strength was 99.8 %. This study provides proof of concept for a new, low cost method of confirming HIV diagnosis in resource-limited settings. It has potential for use as a supplementary test in a confirmatory algorithm, whereby double positive RDT results undergo dilution testing, with positive results confirming HIV infection. Negative results require nucleic acid testing to rule out false negative results due to seroconversion or misclassification by the lower sensitivity dilution test. Further research is needed to determine if these results can be replicated in other settings. ClinicalTrials.gov, NCT01716299 .
40 CFR 1065.805 - Sampling system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Sampling system. 1065.805 Section 1065... ENGINE-TESTING PROCEDURES Testing With Oxygenated Fuels § 1065.805 Sampling system. (a) Dilute engine exhaust, and use batch sampling to collect proportional flow-weighted dilute samples of the applicable...
40 CFR 1065.805 - Sampling system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Sampling system. 1065.805 Section 1065... ENGINE-TESTING PROCEDURES Testing With Oxygenated Fuels § 1065.805 Sampling system. (a) Dilute engine exhaust, and use batch sampling to collect proportional flow-weighted dilute samples of the applicable...
Dilution effects on ultrafine particle emissions from Euro 5 and Euro 6 diesel and gasoline vehicles
NASA Astrophysics Data System (ADS)
Louis, Cédric; Liu, Yao; Martinet, Simon; D'Anna, Barbara; Valiente, Alvaro Martinez; Boreave, Antoinette; R'Mili, Badr; Tassel, Patrick; Perret, Pascal; André, Michel
2017-11-01
Dilution and temperature used during sampling of vehicle exhaust can modify particle number concentration and size distribution. Two experiments were performed on a chassis dynamometer to assess exhaust dilution and temperature on particle number and particle size distribution for Euro 5 and Euro 6 vehicles. In the first experiment, the effects of dilution (ratio from 8 to 4 000) and temperature (ranging from 50 °C to 150 °C) on particle quantification were investigated directly from tailpipe for a diesel and a gasoline Euro 5 vehicles. In the second experiment, particle emissions from Euro 6 diesel and gasoline vehicles directly sampled from the tailpipe were compared to the constant volume sampling (CVS) measurements under similar sampling conditions. Low primary dilutions (3-5) induced an increase in particle number concentration by a factor of 2 compared to high primary dilutions (12-20). Low dilution temperatures (50 °C) induced 1.4-3 times higher particle number concentration than high dilution temperatures (150 °C). For the Euro 6 gasoline vehicle with direct injection, constant volume sampling (CVS) particle number concentrations were higher than after the tailpipe by a factor of 6, 80 and 22 for Artemis urban, road and motorway, respectively. For the same vehicle, particle size distribution measured after the tailpipe was centred on 10 nm, and particles were smaller than the ones measured after CVS that was centred between 50 nm and 70 nm. The high particle concentration (≈106 #/cm3) and the growth of diameter, measured in the CVS, highlighted aerosol transformations, such as nucleation, condensation and coagulation occurring in the sampling system and this might have biased the particle measurements.
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
40 CFR 90.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... sampling probe. (2) Exhaust flow metering system. A dilute exhaust flow metering system must be used to... exhaust. The background probe must draw a representative sample of the background air during each sampling... (bag) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe...
21 CFR 864.5240 - Automated blood cell diluting apparatus.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Automated blood cell diluting apparatus. 864.5240... § 864.5240 Automated blood cell diluting apparatus. (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood sample...
21 CFR 864.5240 - Automated blood cell diluting apparatus.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Automated blood cell diluting apparatus. 864.5240... § 864.5240 Automated blood cell diluting apparatus. (a) Identification. An automated blood cell diluting apparatus is a fully automated or semi-automated device used to make appropriate dilutions of a blood sample...
"Ultra High Dilution 1994" revisited 2015--the state of follow-up research.
Endler, P Christian; Schulte, Jurgen; Stock-Schroeer, Beate; Stephen, Saundra
2015-10-01
The "Ultra High Dilution 1994" project was an endeavour to take stock of the findings and theories on homeopathic extreme dilutions that were under research at the time in areas of biology, biophysics, physics and medicine. The project finally materialized into an anthology assembling contributions of leading scientists in the field. Over the following two decades, it became widely quoted within the homeopathic community and also known in other research communities. The aim of the present project was to re-visit and review the 1994 studies from the perspective of 2015. The original authors from 1994 or close laboratory colleagues were asked to contribute papers covering their research efforts and learnings in the period from 1994 up to 2015. These contributions were edited and cross-referenced, and a selection of further contributions was added. About a dozen contributions reported on follow-up experiments and studies, including further developments in theory. Only few of the models that had seemed promising in 1994 had not been followed up later. Most models presented in the original publication had meanwhile been submitted to intra-laboratory, multicentre or independent scrutiny. The results of the follow-up research seemed to have rewarded the efforts. Furthermore, contributions were provided on new models that had been inspired by the original ones or that may be candidates for further in-depth ultra high dilution (UHD) research. The project "Ultra High Dilution 1994 revisited 2015" is the latest output of what might be considered the "buena vista social club" of homeopathy research. However, it presents new developments and results of the older, established experimental models as well as a general survey of the state of UHD research. Copyright © 2015 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2014 CFR
2014-07-01
... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2012 CFR
2012-07-01
... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2013 CFR
2013-07-01
... “transient” formaldehyde exhaust sample, the “transient” dilution air sample bag, the “transient” methanol... start “transient” exhaust and dilution air bag samples to the analytical system and process the samples... Section 86.537-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS...
Adamik, Katja-Nicole; Butty, Emmanuelle; Howard, Judith
2015-09-24
Hyperosmolar therapy, using either mannitol or hypertonic saline (HTS), is considered the treatment of choice for intracranial hypertension. However, hyperosmolar agents may impair coagulation and platelet function, limiting their use in patients at risk for hemorrhage. Despite this, studies evaluating the effects of mannitol compared to other hyperosmolar agents in dogs are largely lacking. The aim of this study was to compare the in vitro effects on global hemostasis and platelet function of 20% mannitol and 3% HTS on canine blood. Citrated whole blood from 15 healthy dogs was diluted with 0.9% saline, 20% mannitol and 3% HTS in ratios of 1:16 and 1:8. Rotational thromboelastometry (ROTEM) was used to assess clotting time (CT), clot formation time (CFT) and maximal clot firmness (MCF) following extrinsic activation (Ex-tem) and after platelet inhibition (Fib-tem). A platelet function analyzer (PFA-100) was used to assess closure time (Ct(PFA)). No significant differences were observed between untreated whole blood and samples diluted with saline. Samples diluted with both mannitol and HTS were hypocoagulable compared to untreated whole blood samples. At a dilution of 1:16, no significant differences were found between any measured parameter in samples diluted with saline compared to mannitol or HTS. At a 1:8 dilution, Ct(PFA) was prolonged in samples diluted with mannitol and HTS compared to saline, and Ct(PFA) was prolonged more with mannitol than HTS. Ex-tem CT was increased at a 1:8 dilution with mannitol compared to HTS. Ex-tem CFT was prolonged at a 1:8 dilution with both agents compared to saline, and was prolonged more with mannitol than HTS. Ex-tem MCF was reduced at a 1:8 dilution with both agents compared to saline. Data in this study indicate that both mannitol and HTS affect canine platelet function and whole blood coagulation in vitro in a dose-dependent fashion. The most pronounced effects were observed after high dilutions with mannitol, which impaired platelet aggregation, clot formation time, clot strength, and fibrin formation significantly more than HTS. Further in vivo studies are necessary before recommendations can be made.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Steele, W.J.; Williamson, A.D.; McCain, J.D.
1988-04-01
The report describes a transportable sampling apparatus designed to sample incineration sources at municipal and hazardous-waste disposal facilities, and to provide non-contaminated samples of condensable materials. The sample gas, at a flow rate of 10 cubic feet per minute (c f/m), passes through a modified Source Assessment Sampling System (SASS) cyclone and is then diluted with clean air at 100 cf/m by a novel, perforated cone assembly. Rapid uniform dilution takes place through the vigorous mixing of the sample and clean air streams in the dilution chamber. The resultant gas, cooled to about atmospheric conditions, is passed through a mixingmore » section that provides a residence time of about 3 seconds. The resulting aerosol particles are collected on a Teflon-coated glass-fiber filter. These solids, along with those collected in the cyclone, are subsequently provided for chemical and biological assay analysis.« less
Mine, Madisa; Nkoane, Tapologo; Sebetso, Gaseene; Sakyi, Bright; Makhaola, Kgomotso; Gaolathe, Tendani
2013-12-01
The sample requirement of 1 mL for the Roche COBAS AmpliPrep/COBAS TaqMan HIV-1 test, version 2.0 (CAP CTM HIV v2.0) limits its utility in measuring plasma HIV-1 RNA levels for small volume samples from children infected with HIV-1. Viral load monitoring is the standard of care for HIV-1-infected patients on antiretroviral therapy in Botswana. The study aimed to validate the dilution of small volume samples with phosphate buffered saline (1× PBS) when quantifying HIV-1 RNA in patient plasma. HIV RNA concentrations were determined in undiluted and diluted pairs of samples comprising panels of quality assessment standards (n=52) as well as patient samples (n=325). There was strong correlation (R(2)) of 0.98 and 0.95 within the dynamic range of the CAP CTM HIV v2.0 test between undiluted and diluted samples from quality assessment standards and patients, respectively. The difference between viral load measurements of diluted and undiluted pairs of quality assessment standards and patient samples using the Altman-Bland test showed that the 95% limits of agreement were between -0.40 Log 10 and 0.49 Log 10. This difference was within the 0.5 Log 10 which is generally considered as normal assay variation of plasma RNA levels. Dilution of samples with 1× PBS produced comparable viral load measurements to undiluted samples. Copyright © 2013 Elsevier B.V. All rights reserved.
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2010 CFR
2010-07-01
... phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24 hours of... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... the dilute exhaust and dilution air sample collection systems. (4) For methanol-fueled vehicles, with...
40 CFR 86.537-90 - Dynamometer test runs.
Code of Federal Regulations, 2011 CFR
2011-07-01
... phase of the test. Obtain methanol and formaldehyde sample analyses, if applicable, within 24 hours of... minutes of the end of the sample collection phase of the test. Obtain methanol and formaldehyde sample... the dilute exhaust and dilution air sample collection systems. (4) For methanol-fueled vehicles, with...
Chemical Characterization of an Envelope A Sample from Hanford Tank 241-AN-103
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hay, M.S.
2000-08-23
A whole tank composite sample from Hanford waste tank 241-AN-103 was received at the Savannah River Technology Center (SRTC) and chemically characterized. Prior to characterization the sample was diluted to {approximately}5 M sodium concentration. The filtered supernatant liquid, the total dried solids of the diluted sample, and the washed insoluble solids obtained from filtration of the diluted sample were analyzed. A mass balance calculation of the three fractions of the sample analyzed indicate the analytical results appear relatively self-consistent for major components of the sample. However, some inconsistency was observed between results where more than one method of determination wasmore » employed and for species present in low concentrations. A direct comparison to previous analyses of material from tank 241-AN-103 was not possible due to unavailability of data for diluted samples of tank 241-AN-103 whole tank composites. However, the analytical data for other types of samples from 241-AN-103 we re mathematically diluted and compare reasonably with the current results. Although the segments of the core samples used to prepare the sample received at SRTC were combined in an attempt to produce a whole tank composite, determination of how well the results of the current analysis represent the actual composition of the Hanford waste tank 241-AN-103 remains problematic due to the small sample size and the large size of the non-homogenized waste tank.« less
Planer-Friedrich, Britta; Suess, Elke; Scheinost, Andreas C; Wallschläger, Dirk
2010-12-15
In recent years, analytical methods have been developed that have demonstrated that soluble arsenic-sulfur species constitute a major fraction of dissolved arsenic in sulfidic waters. However, an intense debate is going on about the exact chemical nature of these compounds, since X-ray absorption spectroscopy (XAS) data generated at higher (mmol/L) concentrations suggest the presence of (oxy)thioarsenites in such waters, while ion chromatographic (IC) and mass spectroscopic data at lower (μmol/L to nmol/L) concentrations indicate the presence of (oxy)thioarsenates. In this contribution, we connect and explain these two apparently different types of results. We show by XAS that thioarsenites are the primary reaction products of arsenite and sulfide in geochemical model experiments in the complete absence of oxygen. However, thioarsenites are extremely unstable toward oxidation, and convert rapidly into thioarsenates when exposed to atmospheric oxygen, e.g., while waiting for analysis on the chromatographic autosampler. This problem can only be eliminated when the entire chromatographic process is conducted inside a glovebox. We also show that thioarsenites are unstable toward sample dilution, which is commonly employed prior to chromatographic analysis when ultrasensitive detectors like ICP-MS are used. This instability has two main reasons: if pH changes during dilution, then equilibria between individual arsenic-sulfur species rearrange rapidly due to their different stability regions within the pH range, and if pH is kept constant during dilution, then this changes the ratio between OH(-) and SH(-) in solution, which in turn shifts the underlying speciation equilibria. This problem is avoided by analyzing samples undiluted. Our studies show that thioarsenites appear as thioarsenates in IC analyses if oxygen is not excluded completely, and as arsenite if samples are diluted in alkaline anoxic medium. This also points out that thioarsenites are necessary intermediates in the formation of thioarsenates.
Baba, Ryoko; Amano, Yohei; Wada, Yoshiyuki; Kumazawa, Kenji
2017-03-31
The odorants contributing to the characteristic aroma of matcha were investigated by analysis of the headspace samples and the volatile fractions prepared by a combination of solvent extraction and the SAFE techniques using three matcha powders of different grades (high, medium, and low). Gas chromatography-olfactometry of the headspace samples (GCO-H) and aroma extract dilution analysis (AEDA) applied to the volatile fractions revealed 16 (FD factor ≥1) and 39 (FD factor ≥4 3 ) odor-active peaks, respectively. Among them, 14 and 37 of the odorants, most of which were newly detected in matcha, were identified or tentatively identified by GC-MS and GC-O, respectively. By comparing the perceived odorants of three matcha powders, it was revealed that eight compounds with sweet, green, metallic, and floral notes showed high flavor dilution (FD) factors irrespective of the grades. In addition, some odorants were suggested to influence the characteristic aroma of each grade. Furthermore, trans-4,5-epoxy-(E)-2-decenal, one of the potent odorants of matcha, was revealed to exist as a racemic mixture in matcha. This result suggested that trans-4,5-epoxy-(E)-2-decenal is formed by a nonenzymatic reaction in matcha, different from that in black tea, and that the unique manufacturing process of matcha has a close connection with its formation.
NASA Astrophysics Data System (ADS)
Biagioli, Madeleine; Dinic, Jelena; Jimenez, Leidy Nallely; Sharma, Vivek
Free surface flows and drop formation processes present in printing, jetting, spraying, and coating involve the development of columnar necks that undergo spontaneous surface-tension driven instability, thinning, and pinch-off. Stream-wise velocity gradients that arise within the thinning neck create and extensional flow field, which induces micro-structural changes within complex fluids that contribute elastic stresses, changing the thinning and pinch-off dynamics. In this contribution, we use dripping-onto-substrate (DoS) extensional rheometry technique for visualization and analysis of the pinch-off dynamics of dilute and ultra-dilute aqueous polyethylene oxide (PEO) solutions. Using a range of molecular weights, we study the effect of both elasticity and finite extensibility. Both effective relaxation time and the transient extensional viscosity are found to be strongly concentration-dependent even for highly dilute solutions.
Mckee, Anna M.; Spear, Stephen F.; Pierson, Todd W.
2015-01-01
Isolation of environmental DNA (eDNA) is an increasingly common method for detecting presence and assessing relative abundance of rare or elusive species in aquatic systems via the isolation of DNA from environmental samples and the amplification of species-specific sequences using quantitative PCR (qPCR). Co-extracted substances that inhibit qPCR can lead to inaccurate results and subsequent misinterpretation about a species’ status in the tested system. We tested three treatments (5-fold and 10-fold dilutions, and spin-column purification) for reducing qPCR inhibition from 21 partially and fully inhibited eDNA samples collected from coastal plain wetlands and mountain headwater streams in the southeastern USA. All treatments reduced the concentration of DNA in the samples. However, column purified samples retained the greatest sensitivity. For stream samples, all three treatments effectively reduced qPCR inhibition. However, for wetland samples, the 5-fold dilution was less effective than other treatments. Quantitative PCR results for column purified samples were more precise than the 5-fold and 10-fold dilutions by 2.2× and 3.7×, respectively. Column purified samples consistently underestimated qPCR-based DNA concentrations by approximately 25%, whereas the directional bias in qPCR-based DNA concentration estimates differed between stream and wetland samples for both dilution treatments. While the directional bias of qPCR-based DNA concentration estimates differed among treatments and locations, the magnitude of inaccuracy did not. Our results suggest that 10-fold dilution and column purification effectively reduce qPCR inhibition in mountain headwater stream and coastal plain wetland eDNA samples, and if applied to all samples in a study, column purification may provide the most accurate relative qPCR-based DNA concentrations estimates while retaining the greatest assay sensitivity.
Garbarino, John R.; Taylor, Howard E.
1987-01-01
Inductively coupled plasma mass spectrometry is employed in the determination of Ni, Cu, Sr, Cd, Ba, Ti, and Pb in nonsaline, natural water samples by stable isotope dilution analysis. Hydrologic samples were directly analyzed without any unusual pretreatment. Interference effects related to overlapping isobars, formation of metal oxide and multiply charged ions, and matrix composition were identified and suitable methods of correction evaluated. A comparability study snowed that single-element isotope dilution analysis was only marginally better than sequential multielement isotope dilution analysis. Accuracy and precision of the single-element method were determined on the basis of results obtained for standard reference materials. The instrumental technique was shown to be ideally suited for programs associated with certification of standard reference materials.
da Silva, Yvana Lopes Pinheiro; Costa, Rita Zanlorensi Visneck; Pinho, Kátia Elisa Prus; Ferreira, Ricardo Rabello; Schuindt, Sueliton Miyamoto
2015-01-01
Objective To investigate the effects of dilution of paramagnetic contrast agent with iodinated contrast and xylocaine on the signal intensity during magnetic resonance arthrography, and to improve the paramagnetic contrast agent concentration utilized in this imaging modality. Materials and Methods Samples specially prepared for the study with three different concentrations of paramagnetic contrast agent diluted in saline, iodinated contrast agent and xylocaine were imaged with fast spin echo T1-weighted sequences with fat saturation. The samples were placed into flasks and graphical analysis of the signal intensity was performed as a function of the paramagnetic contrast concentration. Results As compared with samples of equal concentrations diluted only with saline, the authors have observed an average signal intensity decrease of 20.67% for iodinated contrast agent, and of 28.34% for xylocaine. However, the increased gadolinium concentration in the samples caused decrease in signal intensity with all the dilutions. Conclusion Minimizing the use of iodinated contrast media and xylocaine and/or the use of a gadolinium concentration of 2.5 mmol/L diluted in saline will improve the sensitivity of magnetic resonance arthrography. PMID:25987746
Use of vitamin B12 in joint lavage for determination of dilution factors of canine synovial fluid.
de Bruin, Tanya; de Rooster, Hilde; van Bree, Henri; Cox, Eric
2005-11-01
To test a modified saline (0.9% NaCl) solution joint washing (lavage) technique that includes the use of vitamin B12 as an internal marker for the evaluation of synovial fluid dilution in lavage samples from canine joints. 9 plasma samples obtained from blood samples of 9 healthy dogs and 9 synovial fluid samples aspirated from stifle joints of 9 cadaveric dogs. Photometric absorbances of 25% vitamin B12 solution, canine synovial fluid, and canine plasma were measured in a spectrophotometer to establish an optimal wavelength for analysis. Canine synovial fluid and plasma samples were mixed with the 25% vitamin B12 solution to obtain 1%, 3%, 5%, 10%, 20%, and 50% solutions of synovial fluid or plasma. Diluted synovial fluid and plasma samples were used to simulate joint lavage samples and to examine the possible interference of these substances (synovial fluid or plasma) with the absorbance of the 25% vitamin B12 solution in photometric analysis. The optimal wavelength was found to be at 550 nm. Canine synovial fluid and plasma samples did not interfere with the absorbance measurements of the 25% vitamin B12 solution up to a 50% dilution of plasma or synovial fluid. The modified saline solution joint lavage method with the use of a 25% vitamin B12 solution as an internal standard provides an accurate and reliable technique for the evaluation of synovial fluid dilution in lavage samples from canine joints.
NASA Astrophysics Data System (ADS)
Ghazali, K. A.; Salleh, S. F.; Riayatsyah, T. M. I.; Aditiya, H. B.; Mahlia, T. M. I.
2016-03-01
Lignocellulosic biomass is one of the promising feedstocks for bioethanol production. The process starts from pre-treatment, hydrolysis, fermentation, distillation and finally obtaining the final product, ethanol. The efficiency of enzymatic hydrolysis of cellulosic biomass depends heavily on the effectiveness of the pre-treatment step which main function is to break the lignin structure of the biomass. This work aims to investigate the effects of dilute acid pre-treatment on the enzymatic hydrolysis of durian seeds waste to glucose and the subsequent bioethanol fermentation process. The yield of glucose from dilute acid pre-treated sample using 0.6% H2SO4 and 5% substrate concentration shows significant value of 23.4951 g/L. Combination of dilute acid pre-treatment and enzymatic hydrolysis using 150U of enzyme able to yield 50.0944 g/L of glucose content higher compared to normal pre-treated sample of 8.1093 g/L. Dilute acid pre-treatment sample also shows stable and efficient yeast activity during fermentation process with lowest glucose content at 2.9636 g/L compared to 14.7583g/L for normal pre-treated sample. Based on the result, it can be concluded that dilute acid pre-treatment increase the yield of ethanol from bioethanol production process.
NASA Astrophysics Data System (ADS)
Paillet, Frederick
2012-08-01
A simple mass-balance code allows effective modeling of conventional fluid column resistivity logs in dilution tests involving column replacement with either distilled water or dilute brine. Modeling a series of column profiles where the inflowing formation water introduces water quality interfaces propagating along the borehole gives effective estimates of the rate of borehole flow. Application of the dilution model yields estimates of borehole flow rates that agree with measurements made with the heat-pulse flowmeter under ambient and pumping conditions. Model dilution experiments are used to demonstrate how dilution logging can extend the range of borehole flow measurement at least an order of magnitude beyond that achieved with flowmeters. However, dilution logging has the same dynamic range limitation encountered with flowmeters because it is difficult to detect and characterize flow zones that contribute a small fraction of total flow when that contribution is superimposed on a larger flow. When the smaller contribution is located below the primary zone, ambient downflow may disguise the zone if pumping is not strong enough to reverse the outflow. This situation can be addressed by increased pumping. But this is likely to make the moveout of water quality interfaces too fast to measure in the upper part of the borehole, so that a combination of flowmeter and dilution method may be more appropriate. Numerical experiments show that the expected weak horizontal flow across the borehole at conductive zones would be almost impossible to recognize if any ambient vertical flow is present. In situations where natural water quality differences occur such as flowing boreholes or injection experiments, the simple mass-balance code can be used to quantitatively model the evolution of fluid column logs. Otherwise, dilution experiments can be combined with high-resolution flowmeter profiles to obtain results not attainable using either method alone.
Holmén, Britt A; Ayala, Alberto
2002-12-01
This paper addresses how current technologies effective for reducing PM emissions of heavy-duty engines may affect the physical characteristics of the particles emitted. Three in-use transit bus configurations were compared in terms of submicron particle size distributions using simultaneous SMPS measurements under two dilution conditions, a minidiluter and the legislated constant volume sampler (CVS). The compressed natural gas (CNG)-fueled and diesel particulate filter (DPF)-equipped diesel configurations are two "green" alternatives to conventional diesel engines. The CNG bus in this study did not have an oxidation catalyst whereas the diesel configurations (with and without particulate filter) employed catalysts. The DPF was a continuously regenerating trap (CRT). Particle size distributions were collected between 6 and 237 nm using 2-minute SMPS scans during idle and 55 mph steady-state cruise operation. Average particle size distributions collected during idle operation of the diesel baseline bus operating on ultralow sulfur fuel showed evidence for nanoparticle growth under CVS dilution conditions relative to the minidiluter. The CRT effectively reduced both accumulation and nuclei mode concentrations by factors of 10-100 except under CVS dilution conditions where nuclei mode concentrations were measured during 55 mph steady-state cruise that exceeded baseline diesel concentrations. The CVS data suggest some variability in trap performance. The CNG bus had accumulation mode concentrations 10-100x lower than the diesel baseline but often displayed large nuclei modes, especially under CVS dilution conditions. Partly this may be explained by the lack of an oxidation catalyst on the CNG, but differences between the minidiluter and CVS size distributions suggest that dilution ratio, temperature-related wall interactions, and differences in tunnel background between the diluters contributed to creating nanoparticle concentrations that sometimes exceeded diesel baseline concentrations when driving under load. The results do not support use of CVS dilution methodology for ultrafine particle sampling, and, despite attention to collection of tunnel blanks in this study, results indicate that a protocol needs to be determined and prescribed for taking into account tunnel blank "emissions" to obtain meaningful comparisons between different technologies. Of critical importance is determining how temperature differences between tunnel blank and test cycle sampling compare in terms of background particle numbers. Total particle number concentrations for the minidiluter sampling point were not significantly different for the two alternative technologies when considering all the steady-cycle data collected. Concentrations ranged from 0.8 to 3 x 10(6) for the baseline bus operating on ultralow sulfur fuel, from 0.5 to 9 x 10(4) for the diesel bus equipped with the CRT filter, and from 1 to 8 x 10(4) particles/cc for the CNG bus.
Seo, Kyo Seong; Chang, Ho Nam; Park, Joong Kon; Choo, Kwang-Ho
2007-09-01
The biochemical oxygen demand (BOD) value is still a key parameter that can determine the level of organics, particularly the content of biodegradable organics in water. In this work, the effects of sample dilution, which should be done inevitably to get appropriate dissolved oxygen (DO) depletion, on the measurement of 5-day BOD (BOD(5)), was investigated with and without seeding using natural and synthetic water. The dilution effects were also evaluated for water samples taken in different seasons such as summer and winter because water temperature can cause a change in the types of microbial species, thus leading to different oxygen depletion profiles during BOD testing. The predation phenomenon between microbial cells was found to be dependent on the inorganic nutrients and carbon sources, showing a change in cell populations according to cell size after 5-day incubation. The dilution of water samples for BOD determination was linked to changes in the environment for microbial growth such as nutrition. The predation phenomenon between microbial cells was more important with less dilution. BOD(5) increased with the specific amount of inorganic nutrient per microbial mass when the natural water was diluted. When seeding was done for synthetic water samples, the seed volume also affected BOD due to the rate of organic uptake by microbes. BOD(5) increased with the specific bacterial population per organic source supplied at the beginning of BOD measurement. For more accurate BOD measurements, specific guidelines on dilution should be established.
Duo, Jia; Dong, Huijin; DeSilva, Binodh; Zhang, Yan J
2013-07-01
Sample dilution and reagent pipetting are time-consuming steps in ligand-binding assays (LBAs). Traditional automation-assisted LBAs use assay-specific scripts that require labor-intensive script writing and user training. Five major script modules were developed on Tecan Freedom EVO liquid handling software to facilitate the automated sample preparation and LBA procedure: sample dilution, sample minimum required dilution, standard/QC minimum required dilution, standard/QC/sample addition, and reagent addition. The modular design of automation scripts allowed the users to assemble an automated assay with minimal script modification. The application of the template was demonstrated in three LBAs to support discovery biotherapeutic programs. The results demonstrated that the modular scripts provided the flexibility in adapting to various LBA formats and the significant time saving in script writing and scientist training. Data generated by the automated process were comparable to those by manual process while the bioanalytical productivity was significantly improved using the modular robotic scripts.
Button, Mark; Weber, Kela; Nivala, Jaime; Aubron, Thomas; Müller, Roland Arno
2016-03-01
Community-level physiological profiling (CLPP) using BIOLOG® EcoPlates™ has become a popular method for characterizing and comparing the functional diversity, functional potential, and metabolic activity of heterotrophic microbial communities. The method was originally developed for profiling soil communities; however, its usage has expanded into the fields of ecotoxicology, agronomy, and the monitoring and profiling of microbial communities in various wastewater treatment systems, including constructed wetlands for water pollution control. When performing CLPP on aqueous samples from constructed wetlands, a wide variety of sample characteristics can be encountered and challenges may arise due to excessive solids, color, or turbidity. The aim of this study was to investigate the impacts of different sample preparation methods on CLPP performed on a variety of aqueous samples covering a broad range of physical and chemical characteristics. The results show that using filter paper, centrifugation, or settling helped clarify samples for subsequent CLPP analysis, however did not do so as effectively as dilution for the darkest samples. Dilution was able to provide suitable clarity for the darkest samples; however, 100-fold dilution significantly affected the carbon source utilization patterns (CSUPs), particularly with samples that were already partially or fully clear. Ten-fold dilution also had some effect on the CSUPs of samples which were originally clear; however, the effect was minimal. Based on these findings, for this specific set of samples, a 10-fold dilution provided a good balance between ease of use, sufficient clarity (for dark samples), and limited effect on CSUPs. The process and findings outlined here can hopefully serve future studies looking to utilize CLPP for functional analysis of microbial communities and also assist in comparing data from studies where different sample preparation methods were utilized.
Wang, Yan Jason; Yang, Bo; Lipsky, Eric M; Robinson, Allen L; Zhang, K Max
2013-01-15
Experimental results from laboratory emission testing have indicated that particulate emission measurements are sensitive to the dilution process of exhaust using fabricated dilution systems. In this paper, we first categorize the dilution parameters into two groups: (1) aerodynamics (e.g., mixing types, mixing enhancers, dilution ratios, residence time); and (2) mixture properties (e.g., temperature, relative humidity, particle size distributions of both raw exhaust and dilution gas). Then we employ the Comprehensive Turbulent Aerosol Dynamics and Gas Chemistry (CTAG) model to investigate the effects of those parameters on a set of particulate emission measurements comparing two dilution tunnels, i.e., a T-mixing lab dilution tunnel and a portable field dilution tunnel with a type of coaxial mixing. The turbulent flow fields and aerosol dynamics of particles are simulated inside two dilution tunnels. Particle size distributions under various dilution conditions predicted by CTAG are evaluated against the experimental data. It is found that in the area adjacent to the injection of exhaust, turbulence plays a crucial role in mixing the exhaust with the dilution air, and the strength of nucleation dominates the level of particle number concentrations. Further downstream, nucleation terminates and the growth of particles by condensation and coagulation continues. Sensitivity studies reveal that a potential unifying parameter for aerodynamics, i.e., the dilution rate of exhaust, plays an important role in new particle formation. The T-mixing lab tunnel tends to favor the nucleation due to a larger dilution rate of the exhaust than the coaxial mixing field tunnel. Our study indicates that numerical simulation tools can be potentially utilized to develop strategies to reduce the uncertainties associated with dilution samplings of emission sources.
Boulyga, Sergei F; Heilmann, Jens; Heumann, Klaus G
2005-08-01
Inductively coupled plasma isotope dilution mass spectrometry (ICP-IDMS) with direct laser-assisted introduction of isotope-diluted samples into the plasma, using a laser ablation system with high ablation rates, was developed for accurate sulfur determinations in different petroleum products such as 'sulfur-free' premium gasoline, diesel fuel, and heating oil. Two certified gas oil reference materials were analyzed for method validation. Two different 34S-enriched spike compounds, namely, elementary sulfur dissolved in xylene and dibenzothiophene in hexane, were synthesized and tested for their usefulness in this isotope dilution technique. The isotope-diluted sample was adsorbed on a filter-paper-like material, which was fixed in a special holder for irradiation by the laser beam. Under these conditions no time-dependent spike/analyte fractionation was only observed for the dibenzothiophene spike during the laser ablation process, which means that the measured 34S/32S isotope ratio of the isotope-diluted sample remained constant-a necessary precondition for accurate results with the isotope dilution technique. A comparison of LA-ICP-IDMS results with the certified values of the gas oil reference materials and with results obtained from ICP-IDMS analyses with wet sample digestion demonstrated the accuracy of the new LA-ICP-IDMS method in the concentration range of 9.2 microg g(-1) ('sulfur-free' premium gasoline) to 10.4 mg g(-1) (gas oil reference material BCR 107). The detection limit for sulfur by LA-ICP-IDMS is 0.04 microg g(-1) and the analysis time is only about 10 min, which therefore also qualifies this method for accurate determinations of low sulfur contents in petroleum products on a routine level.
Monaco, Davide; Fatnassi, Meriem; Padalino, Barbara; Hammadi, Mohamed; Khorchani, Touhami; Lacalandra, Giovanni Michele
2016-04-01
Ejaculates from five clinically healthy dromedary camels (Camelus dromedarius) were used to evaluate the effects of different enzymatic treatments (Amylase, Papain, Spermfluid) on liquefaction and seminal parameters. After collection, ejaculates were divided into 5 aliquots: (1) kept undiluted (control); or diluted 1:1 with: (2) Tris-Citrate-Fructose (TCF), (3) TCF containing Amylase, (4) TCF containing Papain or (5) Spermfluid containing Bromelain. At 120 min after dilution, each aliquot was evaluated, at 20-min intervals, for viscosity, motility, viability and agglutination. Only the aliquots diluted with TCF containing Papain underwent complete liquefaction. Sperm motility decreased significantly during the observation times, except for the samples diluted with Spermfluid (P=0.005). Diluted samples showed different levels of agglutination, with the lowest being observed in the control and the highest in the Papain-treated samples. The viscosity of dromedary camel ejaculates could be effectively reduced by using the proteolytic enzyme Papain. Copyright © 2016 Elsevier Ltd. All rights reserved.
Vitamins D and A can be successfully measured by LC-MS/MS in cord blood diluted plasma.
Albarhani, Ali A; Collier, Fiona; Greaves, Ronda F; Ponsonby, Anne-Louise; Allen, Katrina J; Vuillermin, Peter J; Roche, Peter; Clarke, Michael W
2015-11-01
In widely used protocols for the collection and isolation of cord blood mononuclear cells, investigators are left with substantial volumes of diluted plasma which could be used for other measurements. The aim of this study was to ascertain the validity of umbilical cord blood (UCB) diluted plasma samples for vitamin D, A and E analysis compared to UCB serum samples. Twenty UCB matched samples of diluted plasma and serum were collected. The samples were analysed by two liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods on two separate occasions. The results of 25(OH)D3 obtained by the two laboratories demonstrated close agreement with a mean difference of 0.14nmol/L [95% confidence interval (95% CI), -6.8 to 7.1]. Both methods demonstrate close agreement for 25(OH)D3 in UCB serum versus diluted UCB plasma; mean difference 2.2nmol/L [95% CI, -9.5 to 13.9] and 4.1nmol/L [95% CI, -14.5 to 6.1] for the results from Lab A and Lab B, respectively. Vitamin A was quantified by Lab A in UCB serum and diluted UCB plasma; mean difference 0.07μmol/L [95% CI, -0.41 to 0.28]. Results of 25(OH)D3 epimer and vitamin E in the diluted UCB plasma were below the limit of quantification, and could not be compared with UCB serum. Diluted UCB plasma can be used for the quantification of retinol and 25(OH)D3 by LC-MS/MS. By contrast, quantification of 25(OH)D3 epimer and vitamin E in diluted UCB plasma is not supported by this study due to limitations in analytical sensitivity. Copyright © 2015 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.
Gas electron multiplier (GEM) enhanced ionization chamber for fluorescence detector
NASA Astrophysics Data System (ADS)
Shaban, E. H.; Siddons, D. P.; Kuczewski, A.
2007-11-01
Detecting dilute elements in thin materials using extended X-ray absorption fluorescence spectroscopy (EXAFS) method requires a detector capable of high count rate and low noise. For detection of dilute elements, the fluorescence signal amplitude is often overcome by the presence of noise or background interference. In this paper we have used a gas ionization chamber enhanced by a gas electron multiplier (GEM) to amplify the primary ionized electrons due to the X-ray fluorescence of a dilute element. The GEM provides an essentially noise free electron amplification of the signal primary photoelectrons. It provides a larger output current prior to the electronic amplification, allowing a lower gain amplifier with lower electronic circuit noise contribution and hence improved S/ N ratio. In addition, since the signal is produced only by electrons, and not from ion motion, the detector is capable of recording rapidly changing signals. Iron in an arbitrary tree leaf was used as a test sample. This sample was measured using our detector SUBRSAB, and also with Lytle and passivated implanted planar silicon (PIPS) detectors. An improvement in the signal amplitude by a factor of 20 and a factor of 2 are recorded for the proposed detector with respect to the Lytle and PIPS detectors, respectively. Although the gain in signal over the PIPS detector is small for this detector, its lack of sensitivity to light and its low and temperature-independent dark current are further advantages.
Yi, Xiaoyi; Li, Huizhen; Ma, Ping; You, Jing
2015-08-01
Sediments in urban waterways of Guangzhou, China, were contaminated by a variety of chemicals and showed prevalent toxicity to benthic organisms. A combination of whole-sediment toxicity identification evaluation (TIE) and bioavailability-based extraction was used to identify the causes of sediment toxicity. Of the 6 sediment samples collected, 4 caused 100% mortality to Chironomus dilutus in 10-d bioassays, and the potential toxicants were assessed using TIE in these sediments after dilution. The results of phase I characterization showed that organic contaminants were the principal contributors to the mortality of the midges in 2 sediments and that metals and organics jointly caused the mortality in the other 2 sediments. Ammonia played no role in the mortality for any samples. Conventional toxic unit analysis in phase II testing identified Cr, Cu, Ni, Pb, and Zn as the toxic metals, with cypermethrin, lambda-cyhalothrin, deltamethrin, and fipronils being the toxic organics. To improve the accuracy of identifying the toxicants, 4-step sequential extraction and Tenax extraction were conducted to analyze the bioavailability of the metals and organics, respectively. Bioavailable toxic unit analysis narrowed the list of toxic contributors, and the putative toxicants included 3 metals (Zn, Ni, and Pb) and 3 pesticides (cypermethrin, lambda-cyhalothrin, and fipronils). Metals contributed to the mortality in all sediments, but sediment dilution reduced the toxicity and confounded the characterization of toxicity contribution from metals in 2 sediments in phase I. Incorporating bioavailability-based measurements into whole-sediment TIE improved the accuracy of identifying the causative toxicants in urban waterways where multiple stressors occurred and contributed to sediment toxicity jointly. © 2015 SETAC.
Multi-laboratory survey of qPCR enterococci analysis method performance
Quantitative polymerase chain reaction (qPCR) has become a frequently used technique for quantifying enterococci in recreational surface waters, but there are several methodological options. Here we evaluated how three method permutations, type of mastermix, sample extract dilution and use of controls in results calculation, affect method reliability among multiple laboratories with respect to sample interference. Multiple samples from each of 22 sites representing an array of habitat types were analyzed using EPA Method 1611 and 1609 reagents with full strength and five-fold diluted extracts. The presence of interference was assessed three ways: using sample processing and PCR amplifications controls; consistency of results across extract dilutions; and relative recovery of target genes from spiked enterococci in water sample compared to control matrices with acceptable recovery defined as 50 to 200%. Method 1609, which is based on an environmental mastermix, was found to be superior to Method 1611, which is based on a universal mastermix. Method 1611 had over a 40% control assay failure rate with undiluted extracts and a 6% failure rate with diluted extracts. Method 1609 failed in only 11% and 3% of undiluted and diluted extracts analyses. Use of sample processing control assay results in the delta-delta Ct method for calculating relative target gene recoveries increased the number of acceptable recovery results. Delta-delta tended to bias recoveries fr
Results of Hg speciation testing on tanks 30, 32, and 37 depth samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bannochie, C. J.
2015-11-30
The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team. The twelfth shipment of samples was designated to include 3H evaporator system Tank 30, 32, and 37 depth samples. The Tank 30 depth sample (HTF-30-15-70) was taken at 190 inches from the tank bottom and the Tank 32 depth sample (HTF-32-15-68) was taken at 89 inches from the tank bottom and both were shipped to SRNL on June 29, 2015 in an 80 mLmore » stainless steel dip bottles. The Tank 37 surface sample (HTF-37-15-94) was taken around 253.4 inches from the tank bottom and shipped to SRNL on July 21, 2015 in an 80 mL stainless steel dip bottle. All samples were placed in the SRNL Shielded Cells and left unopened until intermediate dilutions were made on July 24, 2015 using 1.00 mL of sample diluted to 100.00 mL with deionized H 2O. A 30 mL Teflon® bottle was rinsed twice with the diluted tank sample and then filled leaving as little headspace as possible. It was immediately removed from the Shielded Cells and transferred to refrigerated storage where it remained at 4 °C until final dilutions were made on October 20. A second portion of the cells diluted tank sample was poured into a shielded polyethylene bottle and transferred to Analytical Development for radiochemical analysis data needed for Hazardous Material Transportation calculations.« less
Infiltration as Ventilation: Weather-Induced Dilution
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sherman, Max H.; Turner, William J.N.; Walker, Iain S.
The purpose of outdoor air ventilation is to dilute or remove indoor contaminants to which occupants are exposed. It can be provided by mechanical or natural means. In most homes, especially older homes, weather-driven infiltration provides the dominant fraction of the total ventilation. As we seek to provide good indoor air quality at minimum energy cost, it is important to neither over-ventilate nor under-ventilate. Thus, it becomes critically important to evaluate correctly the contribution infiltration makes to the total outdoor air ventilation rate. Because weather-driven infiltration is dependent on building air leakage and weather-induced pressure differences, a given amount ofmore » air leakage will provide different amounts of infiltration. Varying rates of infiltration will provide different levels of contaminant dilution and hence effective ventilation. This paper derives these interactions and then calculates the impact of weather-driven infiltration for different climates. A new “N-factor” is introduced to provide a convenient method for calculating the ventilation contribution of infiltration for over 1,000 locations across North America. The results of this work could be used in indoor air quality standards (specifically ASHRAE 62.2) to account for the contribution of weather-driven infiltration towards the dilution of indoor pollutants.« less
Stark, Peter C.; Kuske, Cheryl R.; Mullen, Kenneth I.
2002-01-01
A method for quantitating dsDNA in an aqueous sample solution containing an unknown amount of dsDNA. A first aqueous test solution containing a known amount of a fluorescent dye-dsDNA complex and at least one fluorescence-attenutating contaminant is prepared. The fluorescence intensity of the test solution is measured. The first test solution is diluted by a known amount to provide a second test solution having a known concentration of dsDNA. The fluorescence intensity of the second test solution is measured. Additional diluted test solutions are similarly prepared until a sufficiently dilute test solution having a known amount of dsDNA is prepared that has a fluorescence intensity that is not attenuated upon further dilution. The value of the maximum absorbance of this solution between 200-900 nanometers (nm), referred to herein as the threshold absorbance, is measured. A sample solution having an unknown amount of dsDNA and an absorbance identical to that of the sufficiently dilute test solution at the same chosen wavelength is prepared. Dye is then added to the sample solution to form the fluorescent dye-dsDNA-complex, after which the fluorescence intensity of the sample solution is measured and the quantity of dsDNA in the sample solution is determined. Once the threshold absorbance of a sample solution obtained from a particular environment has been determined, any similarly prepared sample solution taken from a similar environment and having the same value for the threshold absorbance can be quantified for dsDNA by adding a large excess of dye to the sample solution and measuring its fluorescence intensity.
Combined sewer overflows: an environmental source of hormones and wastewater micropollutants
Phillips, P.J.; Chalmers, A.T.; Gray, J.L.; Kolpin, D.W.; Foreman, W.T.; Wall, G.R.
2012-01-01
Data were collected at a wastewater treatment plant (WWTP) in Burlington, Vermont, USA, (serving 30,000 people) to assess the relative contribution of CSO (combined sewer overflow) bypass flows and treated wastewater effluent to the load of steroid hormones and other wastewater micropollutants (WMPs) from a WWTP to a lake. Flow-weighted composite samples were collected over a 13 month period at this WWTP from CSO bypass flows or plant influent flows (n = 28) and treated effluent discharges (n = 22). Although CSO discharges represent 10% of the total annual water discharge (CSO plus treated plant effluent discharges) from the WWTP, CSO discharges contribute 40–90% of the annual load for hormones and WMPs with high (>90%) wastewater treatment removal efficiency. By contrast, compounds with low removal efficiencies (<90%) have less than 10% of annual load contributed by CSO discharges. Concentrations of estrogens, androgens, and WMPs generally are 10 times higher in CSO discharges compared to treated wastewater discharges. Compound concentrations in samples of CSO discharges generally decrease with increasing flow because of wastewater dilution by rainfall runoff. By contrast, concentrations of hormones and many WMPs in samples from treated discharges can increase with increasing flow due to decreasing removal efficiency.
Combined Sewer Overflows: An Environmental Source of Hormones and Wastewater Micropollutants
2012-01-01
Data were collected at a wastewater treatment plant (WWTP) in Burlington, Vermont, USA, (serving 30,000 people) to assess the relative contribution of CSO (combined sewer overflow) bypass flows and treated wastewater effluent to the load of steroid hormones and other wastewater micropollutants (WMPs) from a WWTP to a lake. Flow-weighted composite samples were collected over a 13 month period at this WWTP from CSO bypass flows or plant influent flows (n = 28) and treated effluent discharges (n = 22). Although CSO discharges represent 10% of the total annual water discharge (CSO plus treated plant effluent discharges) from the WWTP, CSO discharges contribute 40–90% of the annual load for hormones and WMPs with high (>90%) wastewater treatment removal efficiency. By contrast, compounds with low removal efficiencies (<90%) have less than 10% of annual load contributed by CSO discharges. Concentrations of estrogens, androgens, and WMPs generally are 10 times higher in CSO discharges compared to treated wastewater discharges. Compound concentrations in samples of CSO discharges generally decrease with increasing flow because of wastewater dilution by rainfall runoff. By contrast, concentrations of hormones and many WMPs in samples from treated discharges can increase with increasing flow due to decreasing removal efficiency. PMID:22540536
Diemer, J; Quétel, C R; Taylor, P D P
2002-09-01
The contribution of the Institute for Reference Materials and Measurements to the certification of the B, Cd, Cu, Mg, and Pb content of a synthetic water sample used in Comparison 12 of the International Measurement Evaluation Programme (IMEP-12) is described. The aim of the IMEP programme is to demonstrate objectively the degree of equivalence and quality of chemical measurements of individual laboratories on the international scene by comparing them with reference ranges traceable to the SI (Système International d'Unités). IMEP is organized in support of European Union policies and helps to improve the traceability of values produced by field chemical measurement laboratories. The analytical procedure used to establish the reference values for the B, Cd, Cu, Mg, and Pb content of the IMEP-12 sample is based on inductively coupled plasma-isotope-dilution mass spectrometry (ICP-IDMS) applied as a primary method of measurement. The measurements performed for the IMEP-12 study are described in detail. Focus is on the element boron, which is particularly difficult to analyze by ICP-MS because of potential problems of low sensitivity, high mass discrimination, memory effects, and abundance sensitivity. For each of the certified amount contents presented here a total uncertainty budget was calculated using the method of propagation of uncertainties according to ISO (International Organization for Standardization) and Eurachem guidelines. For all investigated elements with concentrations in the low micro g kg(-1) and mg kg(-1) range (corresponding to pmol kg(-1) to the high micro mol kg(-1) level), SI-traceable reference values with relative expanded uncertainties ( k=2) of less than 2 % were obtained.
Microfluidic Serial Dilution Circuit
Paegel, Brian M.; Grover, William H.; Skelley, Alison M.; Mathies, Richard A.; Joyce, Gerald F.
2008-01-01
In vitro evolution of RNA molecules requires a method for executing many consecutive serial dilutions. To solve this problem, a microfluidic circuit has been fabricated in a three-layer glass-PDMS-glass device. The 400-nL serial dilution circuit contains five integrated membrane valves: three two-way valves arranged in a loop to drive cyclic mixing of the diluent and carryover, and two bus valves to control fluidic access to the circuit through input and output channels. By varying the valve placement in the circuit, carryover fractions from 0.04 to 0.2 were obtained. Each dilution process, which is comprised of a diluent flush cycle followed by a mixing cycle, is carried out with no pipeting, and a sample volume of 400 nL is sufficient for conducting an arbitrary number of serial dilutions. Mixing is precisely controlled by changing the cyclic pumping rate, with a minimum mixing time of 22 s. This microfluidic circuit is generally applicable for integrating automated serial dilution and sample preparation in almost any microfluidic architecture. PMID:17073422
Particles size distribution in diluted magnetic fluids
NASA Astrophysics Data System (ADS)
Yerin, Constantine V.
2017-06-01
Changes in particles and aggregates size distribution in diluted kerosene based magnetic fluids is studied by dynamic light scattering method. It has been found that immediately after dilution in magnetic fluids the system of aggregates with sizes ranging from 100 to 250-1000 nm is formed. In 50-100 h after dilution large aggregates are peptized and in the sample stationary particles and aggregates size distribution is fixed.
NASA Astrophysics Data System (ADS)
García-Resúa, Carlos; Pena-Verdeal, Hugo; Miñones, Mercedes; Gilino, Jorge; Giraldez, Maria J.; Yebra-Pimentel, Eva
2013-11-01
High tear fluid osmolarity is a feature common to all types of dry eye. This study was designed to establish the accuracy of two osmometers, a freezing point depression osmometer (Fiske 110) and an electrical impedance osmometer (TearLab™) by using standard samples. To assess the accuracy of the measurements provided by the two instruments we used 5 solutions of known osmolarity/osmolality; 50, 290 and 850 mOsm/kg and 292 and 338 mOsm/L. Fiske 110 is designed to be used in samples of 20 μl, so measurements were made on 1:9, 1:4, 1:1 and 1:0 dilutions of the standards. Tear Lab is addressed to be used in tear film and only a sample of 0.05 μl is required, so no dilutions were employed. Due to the smaller measurement range of the TearLab, the 50 and 850 mOsm/kg standards were not included. 20 measurements per standard sample were used and differences with the reference value was analysed by one sample t-test. Fiske 110 showed that osmolarity measurements differed statistically from standard values except those recorded for 290 mOsm/kg standard diluted 1:1 (p = 0.309), the 292 mOsm/L H2O sample (1:1) and 338 mOsm/L H2O standard (1:4). The more diluted the sample, the higher the error rate. For the TearLab measurements, one-sample t-test indicated that all determinations differed from the theoretical values (p = 0.001), though differences were always small. For undiluted solutions, Fiske 110 shows similar performance than TearLab. However, for the diluted standards, Fiske 110 worsens.
Bi, Xiufang; Hemar, Yacine; Balaban, Murat O; Liao, Xiaojun
2015-11-01
The effect of ultrasound treatment on particle size, color, viscosity, polyphenol oxidase (PPO) activity and microstructure in diluted avocado puree was investigated. The treatments were carried out at 20 kHz (375 W/cm(2)) for 0-10 min. The surface mean diameter (D[3,2]) was reduced to 13.44 μm from an original value of 52.31 μm by ultrasound after 1 min. A higher L(∗) value, ΔE value and lower a(∗) value was observed in ultrasound treated samples. The avocado puree dilution followed pseudoplastic flow behavior, and the viscosity of diluted avocado puree (at 100 s(-1)) after ultrasound treatment for 1 min was 6.0 and 74.4 times higher than the control samples for dilution levels of 1:2 and 1:9, respectively. PPO activity greatly increased under all treatment conditions. A maximum increase of 25.1%, 36.9% and 187.8% in PPO activity was found in samples with dilution ratios of 1:2, 1:5 and 1:9, respectively. The increase in viscosity and measured PPO activity might be related to the decrease in particle size. The microscopy images further confirmed that ultrasound treatment induced disruption of avocado puree structure. Copyright © 2015 Elsevier B.V. All rights reserved.
D'Autry, Ward; Zheng, Chao; Wolfs, Kris; Yarramraju, Sitaramaraju; Hoogmartens, Jos; Van Schepdael, Ann; Adams, Erwin
2011-06-01
Static headspace (HS) sampling has been commonly used to test for volatile organic chemicals, usually referred to as residual solvents (RS) in pharmaceuticals. If the sample is not soluble in water, organic solvents are used. However, these seriously reduce the sensitivity in the determination of some RS. Here, mixed aqueous dilution media (a mixture of water and an organic solvent like dimethyl formamide, dimethyl sulfoxide or dimethyl acetamide) were studied as alternative media for static HS-gas chromatographic analysis. Although it has been known that mixed aqueous dilution media can often improve sensitivity for many RS, this study used a systematic approach to investigate phase volumes and the organic content in the HS sampling media. Reference solutions using 18 different class 1, 2 and 3 RS were evaluated. The effect of salt addition was also studied in this work. A significant increase in the peak area was observed for all RS using mixed aqueous dilution media, when compared with organic solvents alone. Matrix effects related to the mixed aqueous dilution media were also investigated and reported. Repeatability and linearity obtained with mixed aqueous dilution media were found to be similar to those observed with pure organic solvents. Copyright © 2011 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Effects of diluting medium and holding time on sperm motility analysis by CASA in ram.
Mostafapor, Somayeh; Farrokhi Ardebili, Farhad
2014-01-01
The aim of this study was to evaluate the effects of dilution rate and holding time on various motility parameters using computer-assisted sperm analysis (CASA). The semen samples were collected from three Ghezel rams. Samples were diluted in seminal plasma (SP), phosphate-buffered saline (PBS) containing 1% bovine serum albumin (BSA) and Bioexcell. The motility parameters that computed and recorded by CASA include curvilinear velocity (VCL), straight line velocity (VSL), average path velocity (VAP), straightness (STR), linearity (LIN), amplitude of lateral head displacement (ALH), and beat cross frequency (BCF). In all diluters, there was a decrease in the average of all three parameters of sperms movement velocity as the time passed, but density of this decrease was more intensive in SP. The average of ALH between diluters indicated a significant difference, as it was more in Bioexcell in comparison with the similar amount in SP and PBS. The average of LIN in the diluted sperms in Bioexcell was less than two other diluters in all three times. The motility parameters of the diluted sperms in Bioexcell and PBS indicated an important and considerable difference with the diluted sperms in SP. According to the gained results, the Bioexcell has greater ability in preserving motility of sperm in comparison with the other diluters but as SP is considered as physiological environment for sperm. It seems that the evaluation of the motility parameters in Bioexcell and PBS cannot be an accurate and comparable evaluation with SP.
Entrainment vs. Dilution in Tropical Deep Convection
NASA Astrophysics Data System (ADS)
Hannah, W.
2017-12-01
The distinction between entrainment and dilution is investigated with cloud resolving simulations of deep convection in a tropical environment. A method for estimating the rate of dilution by entrainment and detrainment is calculated for a series of bubble simulations with a range of initial radii. Entrainment generally corresponds to dilution of convection, but the two quantities are not well correlated. Core dilution by entrainment is significantly reduced by the presence of a shell of moist air around the core. Entrainment contributes significantly to the total net dilution, but detrainment and the various source/sink terms play large roles depending on the variable in question. Detrainment has a concentrating effect on average that balances out the dilution by entrainment. The experiments are also used to examine whether entrainment or dilution scale with cloud radius. The results support a weak negative relationship for dilution, but not for entrainment. The sensitivity to resolution is briefly discussed. A toy Lagrangian thermal model is used to demonstrate the importance of the cloud shell as a thermodynamic buffer to reduce the dilution of the core by entrainment. The results suggest that explicit cloud heterogeneity may be a useful consideration for future convective parameterization development.
Kelly, W Robert; Long, Stephen E; Mann, Jacqueline L
2003-07-01
Mercury was determined by isotope dilution cold-vapor inductively coupled plasma mass spectrometry (ID-CV-ICP-MS) in four different liquid petroleum SRMs. Samples of approximately 0.3 g were spiked with stable (201)Hg and wet ashed in a closed system (Carius tube) using 6 g of high-purity nitric acid. Three different types of commercial oils were measured: two Texas crude oils, SRM 2721 (41.7+/-5.7 pg g(-1)) and SRM 2722 (129+/-13 pg g(-1)), a low-sulfur diesel fuel, SRM 2724b (34+/-26 pg g(-1)), and a low-sulfur residual fuel oil, SRM 1619b (3.5+/-0.74 ng g(-1)) (mean value and 95% CI). The Hg values for the crude oils and the diesel fuel are the lowest values ever reported for these matrices. The method detection limit, which is ultimately limited by method blank uncertainty, is approximately 10 pg g(-1) for a 0.3 g sample. Accurate Hg measurements in petroleum products are needed to assess the contribution to the global Hg cycle and may be needed in the near future to comply with reporting regulations for toxic elements.
Zack, Allen L.; Roberts, Ivan
1988-01-01
The Black Creek aquifer contains dilute seawater near the North Carolina State line, probably the result of incomplete flushing of ancient seawater. Data do not indicate that the dilute seawater has migrated toward areas of fresh ground-water withdrawals. The concentration of chloride in ground-water samples ranges from 5 to 720 milligrams per liter and that of sodium from 160 to 690 milligrams per liter. Ion-exchange reactions (sodium for calcium and fluoride for hydroxyl) occur with the calcium carbonate dissolution reaction which produces calcium, bicarbonate, and hydroxyl ions. The reaction sequence and stoichiometry result in an aqueous solution in which the sum of bicarbonate and chloride equivalents per liter is equal to the equivalents per liter of sodium. Calcium ions are exchanged for sodium ions derived from sodium-rich clays upgradient of the dilute seawater. The cation-exchange reaction equilibrates at a sodium concentration of 280 milligrams per liter. Amounts of sodium greater than 280 milligrams per liter are contributed from dilute seawater. The cation-exchange reaction approaches an equilibrium which represents a mass-action limit in terms of the ratio of sodium to calcium in solution versus the ratio of exchangeable sodium to calcium on clay surfaces. Where the limit of calcium carbonate solubility is approached and dissolution ceases, some precipitation of calcite probably takes place. The dissolution of calcite exposes fossil shark teeth which release fluoride ions to the ground water through anion exchange with aqueous hydroxyl ions.
Automated agar plate streaker: a linear plater on Society for Biomolecular Sciences standard plates.
King, Gregory W; Kath, Gary S; Siciliano, Sal; Simpson, Neal; Masurekar, Prakash; Sigmund, Jan; Polishook, Jon; Skwish, Stephen; Bills, Gerald; Genilloud, Olga; Peláez, Fernando; Martín, Jesus; Dufresne, Claude
2006-09-01
Several protocols for bacterial isolation and techniques for aerobic plate counting rely on the use of a spiral plater to deposit concentration gradients of microbial suspensions onto a circular agar plate to isolate colony growth. The advantage of applying a gradient of concentrations across the agar surface is that the original microbiological sample can be applied at a single concentration rather than as multiple serial dilutions. The spiral plater gradually dilutes the sample across a compact area and therefore saves time preparing dilutions and multiple agar plates. Commercial spiral platers are not automated and require manual sample loading. Dispensing of the sample volume and rate of gradients are often very limited in range. Furthermore, the spiral sample application cannot be used with rectangular microplates. Another limitation of commercial spiral platers is that they are useful only for dilute, filtered suspensions and cannot plate suspensions of coarse organic particles therefore precluding the use of many kinds of microorganism-containing substrata. An automated agar plate spreader capable of processing 99 rectangular microplates in unattended mode is described. This novel instrument is capable of dispensing discrete volumes of sample in a linear pattern. It can be programmed to dispense a sample suspense at a uniform application rate or across a decreasing concentration gradient.
Miracolo, Marissa A; Drozd, Greg T; Jathar, Shantanu H; Presto, Albert A; Lipsky, Eric M; Corporan, Edwin; Robinson, Allen L
2012-08-07
A series of smog chamber experiments were performed to investigate the effects of fuel composition on secondary particulate matter (PM) formation from dilute exhaust from a T63 gas-turbine engine. Tests were performed at idle and cruise loads with the engine fueled on conventional military jet fuel (JP-8), Fischer-Tropsch synthetic jet fuel (FT), and a 50/50 blend of the two fuels. Emissions were sampled into a portable smog chamber and exposed to sunlight or artificial UV light to initiate photo-oxidation. Similar to previous studies, neat FT fuel and a 50/50 FT/JP-8 blend reduced the primary particulate matter emissions compared to neat JP-8. After only one hour of photo-oxidation at typical atmospheric OH levels, the secondary PM production in dilute exhaust exceeded primary PM emissions, except when operating the engine at high load on FT fuel. Therefore, accounting for secondary PM production should be considered when assessing the contribution of gas-turbine engine emissions to ambient PM levels. FT fuel substantially reduced secondary PM formation in dilute exhaust compared to neat JP-8 at both idle and cruise loads. At idle load, the secondary PM formation was reduced by a factor of 20 with the use of neat FT fuel, and a factor of 2 with the use of the blend fuel. At cruise load, the use of FT fuel resulted in no measured formation of secondary PM. In every experiment, the secondary PM was dominated by organics with minor contributions from sulfate when the engine was operated on JP-8 fuel. At both loads, FT fuel produces less secondary organic aerosol than JP-8 because of differences in the composition of the fuels and the resultant emissions. This work indicates that fuel reformulation may be a viable strategy to reduce the contribution of emissions from combustion systems to secondary organic aerosol production and ultimately ambient PM levels.
Kwok, Wai Him; Choi, Timmy L S; Kwok, Karen Y; Chan, George H M; Wong, Jenny K Y; Wan, Terence S M
2016-06-17
The high sensitivity of ultra high performance liquid chromatography coupled with high resolution mass spectrometry (UHPLC-HRMS) allows the identification of many prohibited substances without pre-concentration, leading to the development of simple and fast 'dilute-and-shoot' methods for doping control for human and equine sports. While the detection of polar drugs in plasma and urine is difficult using liquid-liquid or solid-phase extraction as these substances are poorly extracted, the 'dilute-and-shoot' approach is plausible. This paper describes a 'dilute-and-shoot' UHPLC-HRMS screening method to detect 46 polar drugs in equine urine and plasma, including some angiotensin-converting enzyme (ACE) inhibitors, sympathomimetics, anti-epileptics, hemostatics, the new doping agent 5-aminoimidazole-4-carboxamide-1-β-d-ribofuranoside (AICAR), as well as two threshold substances, namely dimethyl sulfoxide and theobromine. For plasma, the sample (200μL) was protein precipitated using trichloroacetic acid, and the resulting supernatant was diluted using Buffer A with an overall dilution factor of 3. For urine, the sample (20μL) was simply diluted 50-fold with Buffer A. The diluted plasma or urine sample was then analysed using a UHPLC-HRMS system in full-scan ESI mode. The assay was validated for qualitative identification purpose. This straightforward and reliable approach carried out in combination with other screening procedures has increased the efficiency of doping control analysis in the laboratory. Moreover, since the UHPLC-HRMS data were acquired in full-scan mode, the method could theoretically accommodate an unlimited number of existing and new doping agents, and would allow a retrospectively search for drugs that have not been targeted at the time of analysis. Copyright © 2016 Elsevier B.V. All rights reserved.
Hydrocarbon ratios during PEM-WEST A: A model perspective
NASA Astrophysics Data System (ADS)
McKeen, S. A.; Liu, S. C.; Hsie, E.-Y.; Lin, X.; Bradshaw, J. D.; Smyth, S.; Gregory, G. L.; Blake, D. R.
1996-01-01
A useful application of the hydrocarbon measurements collected during the Pacific Exploratory Mission (PEM-West A) is as markers or indices of atmospheric processing. Traditionally, ratios of particular hydrocarbons have been interpreted as photochemical indices, since much of the effect due to atmospheric transport is assumed to cancel by using ratios. However, an ever increasing body of observatonial and theoretical evidence suggests that turbulent mixing associated with atmospheric transport influences certain hydrocarbon ratios significantly. In this study a three-dimensional mesoscale photochemical model is used to study the interaction of photochemistry and atmospheric mixing on select hydrocarbons. In terms of correlations and functional relationships between various alkanes, the model results and PEM-West A hydrocarbon observations share many similar characteristics as well as explainable differences. When the three-dimensional model is applied to inert tracers, hydrocarbon ratios andother relationships exactly follow those expected by simple dilution with model-imposed "background air," and the three-dimensional results for reactive hydrocarbons are quite consistent with a combined influence of photochemistry and simple dilution. Analogous to these model results, relationships between various hydrocarbons collected during the PEM-West A experiment appear to be consistent with this simplified picture of photochemistry and dilution affecting individual air masses. When hydrocarbons are chosen that have negligible contributions to clean background air, unambiguous determinations of the relative contributions to photochemistry and dilution can be estimated from the hydrocarbon samples. Both the three-dimensional model results and the observations imply an average characteristic lifetime for dilution with background air roughly equivalent to the photochemical lifetime of butane for the western Pacific lower troposphere. Moreover, the dominance of OH as the primary photochemical oxidant downwind of anthropogenic source regions can be inferred from correlations between the highly reactive alkane ratios. By incorporating back-trajectory information within the three-dimensional model analysis, a correspondence between time and a particular hydrocarbon or hydrocarbon ratio can be determined, and the influence of atmospheric mixing or photochemistry can be quantified. Results of the three-dimensional model study are compared and applied to the PEM-West A hydrocarbon dataset, yielding a practical methodology for determining average OH concentrations and atmospheric mixing rates from the hydrocarbon measurements. Aircraft data taken below 2 km during wall flights east of Japan imply a diurnal average OH concentration of ˜3 × 106 cm-3. The characteristic time for dilution with background air is estimated to be ˜2.5 days for the two study areas examined in this work.
Rotor for processing liquids using movable capillary tubes
Johnson, Wayne F.; Burtis, Carl A.; Walker, William A.
1989-01-01
A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described.
Rotor for processing liquids using movable capillary tubes
Johnson, Wayne F [Loudon, TN; Burtis, Carl A [Oak Ridge, TN; Walker, William A [Knoxville, TN
1989-05-30
A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described.
Miraglia, Fabiana; de Moraes, Zenaide Maria; Melville, Priscilla Anne; Dias, Ricardo Augusto; Vasconcellos, Silvio Arruda
2009-01-01
Bovine semen experimentally contaminated with Leptospira santarosai serovar Guaricura was submitted to the modified EMJH medium with 5-fluorouracil (300mg/L) and nalidixic acid (20mg/L), named as “selective medium” and using the serial dilution technique, in order to evaluate the percentage of recovery of the added microorganism. The selective EMJH medium was found with higher percentage of recovery of leptospiras and minor losses of samples due to contamination with opportunistic microorganisms than the non-selective EMJH medium: 151/376 (40.0%) of positive growth; and 38/376 (10.0%) contamination and 58/376 (15%) and 129/376 (34.0%), respectively. These results were statistically significant (p<0. 0001; Fisher). Differences were found when the frequencies of positive leptospires recovery have been compared in the serial dilution technique (10-1 to 10-4) between the selective and non-selective media at different dilution factors. At 1/10th dilution the percentages found were (0%, 0/80) and (38%, 30/80), at 1/100th dilution, (3%, 2/80) and (49%, 39/ 80) and at 1/1,000th dilution, (25%, 20/80) and (50%, 40/80), respectively. The percentage of recovery of leptospires was found to be directly proportional to the dilution used. The methodology of the serial dilution technique (setting at least three dilutions) and the use of selective EMJH medium have been found to be efficient for the isolation of leptospires from the bovine semen samples. PMID:24031342
Krata, Agnieszka; Vassileva, Emilia; Bulska, Ewa
2016-11-01
The analytical procedures for reference measurements of the total Hg and methyl mercury (MeHg) mass fractions at various concentration levels in marine biota samples, candidates for certified reference materials (oyster and clam Gafrarium tumidum), were evaluated. Two modes of application of isotope dilution inductively coupled plasma mass spectrometry method (ID ICP-MS), namely direct isotope dilution and species-specific isotope dilution analysis with the use of two different quantification mass spectrometry techniques were compared. The entire ID ICP-MS measurement procedure was described by mathematical modelling and the combined uncertainty of measurement results was estimated. All factors influencing the final results as well as isotopic equilibrium were systematically investigated. This included the procedural blank, the moisture content in the biota samples and all factors affecting the blend ratio measurements (instrumental background, spectral interferences, dead time and mass discrimination effects as well as the repeatability of measured isotopic ratios). Modelling of the entire measurement procedures and the use of appropriate certified reference materials enable to assure the traceability of obtained values to the International System of Units (SI): the mole or the kilogram. The total mass fraction of mercury in oyster and clam biota samples, after correction for moisture contents, was found to be: 21.1 (1.1) 10(-9) kg kg(-1) (U =5.1% relative, k=2) and 390.0 (9.4) 10(-9) kg kg(-1) (U=2.4% relative, k=2), respectively. For the determination of mercury being present as methyl mercury, the non-chromatographic separation on anion-exchange resin AG1-X8 of the blended samples was applied. The content of MeHg (as Hg) in oyster sample was found: 4.81 (24) 10(-9)kgkg(-1) (U=5.0%, k=2) and 4.84 (21) 10(-9)kgkg(-1) (U=4.3%, k=2) with the use of quadrupole (ICP QMS) or sector field (ICP SFMS) inductively coupled plasma mass spectrometers, respectively. In the case of clam sample, the concentration of MeHg (as Hg) was found to be: 61.0 (2.3) 10(-)(9)kgkg(-1) (U=3.8%, k=2) and 61.3 (2.2) 10(-)(9)kgkg(-1) (U=3.6%, k=2), respectively. The mass fractions for total Hg and MeHg determined in this study were used as a contribution of the International Atomic Energy Agency (IAEA) Environment Laboratories in the characterisation of the IAEA 461 and IAEA 470 certified reference materials. The obtained good agreement with the reference values further validated the methods developed in this study. Copyright © 2016 Elsevier B.V. All rights reserved.
DenHerder, Johnathan M; Reed, Ralph L; Sargent, Jennifer L; Bobe, Gerd; Stevens, Jan F; Diggs, Helen E
2017-01-01
Buprenorphine is a partial μ-opioid agonist used for analgesia. Due to the small size of laboratory rodents, buprenorphine HCl is typically diluted 10- or 20-fold with a sterile diluent, such as saline, for accurate dosing. Protocols for preparing and storing diluted buprenorphine vary by institution, and little published information is available regarding stability and beyond-use dating of specific buprenorphine preparations. The purpose of this study was to determine the chemical and microbiologic stability of diluted buprenorphine stored for a maximum of 180 d. Buprenorphine HCl was diluted 1:10 into sterile bacteriostatic saline by using aseptic technique. Diluted samples were stored in glass vials or plastic syringes, protected from light, and maintained at refrigerated or room temperature for as long as 180 d. Aerobic and anaerobic cultures on all stored samples were negative for bacterial and fungal growth. According to HPLC analysis, diluted buprenorphine stored in glass vials experienced less than 10% loss when stored for 180 d at either refrigerated or room temperature. However, the concentration of buprenorphine stored in syringes declined rapidly to more than 80% loss at room temperature and 28% loss in the refrigerator after 180 d. According to the results of this study, diluted buprenorphine stored in glass vials retains more than 90% of the initial concentration and is microbiologically stable for 180 d. However, our data suggest that, regardless of the duration, storing diluted buprenorphine in plastic syringes is inadvisable. PMID:28724496
Godshaw, Joshua; Hopfer, Helene; Nelson, Jenny; Ebeler, Susan E
2017-09-25
Wine elemental composition varies by cultivar, geographic origin, viticultural and enological practices, and is often used for authenticity validation. Elemental analysis of wine by Inductively Coupled Plasma Mass Spectrometry (ICP-MS) is challenging due to the potential for non-spectral interferences and plasma instability arising from organic matrix components. Sample preparation mitigates these interferences, however, conflicting recommendations of best practices in ICP-MS analysis of wine have been reported. This study compared direct dilution, microwave-assisted acid digestion, and two filtration sample pretreatments, acidification prior to filtration and filtration followed by acidification, in elemental profiling of one white and three red table wines by ICP-MS. Of 43 monitored isotopes, 37 varied by sample preparation method, with significantly higher results of 17 isotopes in the microwave-digested samples. Both filtration treatments resulted in lower results for 11 isotopes compared to the other methods. Finally, isotope dilution determination of copper based on natural abundances and the 63 Cu: 65 Cu instrument response ratio agreed with external calibration and confirmed a significant sample preparation effect. Overall, microwave digestion did not compare favorably, and direct dilution was found to provide the best compromise between ease of use and result accuracy and precision, although all preparation strategies were able to differentiate the wines.
High preservation of DNA standards diluted in 50% glycerol.
Schaudien, Dirk; Baumgärtner, Wolfgang; Herden, Christiane
2007-09-01
Standard curves are important tools in real-time quantitative polymerase chain reaction (PCR) to precisely analyze gene expression patterns under physiologic and pathologic conditions. Handling of DNA standards often implies multiple cycles of freezing and thawing that might affect DNA stability and integrity. This in turn might influence the reliability and reproducibility of quantitative measurements in real-time PCR assays. In this study, 3 DNA standards such as murine tumor necrosis factor (TNF) alpha, interferon (IFN) gamma, and kainat-1 receptor were diluted in 50% glycerol or water after 1, 4, and 16 cycles of freezing and thawing and amplified copy numbers after real-time PCR were compared. The standards diluted in water showed a reduction to 83%, 55%, and 50% after 4 cycles, to 24%, 5%, and 4% after 16 cycles for kainat-1 receptor, TNFalpha, and IFNgamma standards, respectively, when compared with a single cycle of freezing and thawing. Interestingly, all cDNA samples diluted in 50% glycerol were amplified in comparable copy numbers even after 16 cycles of freezing and thawing. The effect of the standards undergoing different cycles of freezing and thawing on sample values was demonstrated by amplifying cDNA obtained from Borna disease virus infected and noninfected TNF-transgenic mice brain. This revealed significant differences of measured cDNA copy numbers using water-diluted DNA standards. In contrast, sample values did not vary using glycerol-diluted standards that were frozen and thawed for 16 times. In conclusion, glycerol storage of DNA standards represents a suitable tool for the accurate and reproducible quantification of cDNA samples in real-time PCR analysis.
[Polymerase chain reaction (PCR) for the identification of toxigenic Vibrio cholerae O1 in oysters].
Rodríguez-Angeles, M G; Giono-Cerezo, S; Moreno-Escobar, A; Valdespino-Gómez, J L
1994-01-01
PCR was made with ctx2 (CGG GCA GAT TCT AGA CCT CCT G) y ctx3 (CGA TGA TCT TGG AGC ATT CCC AC) primers for subunit A of cholera toxin, 30 cycles of temperature on samples of 50 g of oysters added in 450 ml of peptone alcaline water that were inoculated with 15 x 10(6), 0.75 x 10(6) and 0.15 x 10(6) CFU/ml of toxigenic 6707 V. cholerae O1 reference strain. The samples were tested by three microbiological methods: INDRE's method uses 1 x 10(-1) dilution of sample, two fold pass to peptone alcaline water pH 9 incubated 18 h and 6 h at 37 degrees C, the Food and Drugs Administration (FDA) method uses 10(-1) to 10(-6) dilutions of sample, 6 h incubation and reincubation for 18 h at 37 and 42 degrees C and the Mexican laboratories (LMD) with 10(-4) to 10(-3) dilutions, the samples were incubated for 6 h and then reincubated for 18 h at two temperatures 37 and 42 degrees C. The PCR by INDRE's method was positive with 3 x 10(2) CFU/ml/g oyster. In the FDA's method the PCR detected DNA in 10(-4) dilution with 3 x 10(1) CFU/ml/g oyster and in LMD's method the PCR was positive in 10(-3) with 3 CFU/ml/g oyster. The results of the PCR were obtained between 5-6 h, and later V. cholerae O1 was isolated by three microbiological methods. The PCR reproducibility was better on DNA sample diluted 1:4 and 10 microliters of sample increased from 1:1000 to 1:10000 the sensitivity of PCR.
Radiorespirometric assays for the detection of biogenic sulfides from sulfate-reducing bacteria.
de Queiroz, J C; de Melo Ferreira, A C; da Costa, A C A
2013-04-01
The detection of trace concentrations of biogenic sulfides can be carried out through radiorespirometric assays. The objective of this work was to improve the methodology for detection of H2 S in trace concentrations, to correlate with sulfate-reducing bacterial activity. Serial dilutions of synthetic sea water with a pure culture of Desulfovibrio alaskensis, a mixed anaerobic microbial culture and a natural saline sample from a petroleum offshore platform indicated that dilutions were followed, accordingly, by sulfate reduction. Tests performed indicated that increasing the time of incubation of a mixed anaerobic microbial culture contributed to an increase in the sulfate reduction rates, as well as the amount of carbon source and inoculum. The technique here developed proved to be a rapid test for the detection of biogenic sulfides, particularly those associated with corrosion products, being an useful tool for monitoring and controlling oil/water storage tanks, petroleum continental platforms and several types of reservoirs. © 2013 The Society for Applied Microbiology.
Park, Jong-Ho; Choi, Eun-Ju
2016-11-01
A method to determine the quantity and isotopic ratios of uranium in individual micro-particles simultaneously by isotope dilution thermal ionization mass spectrometry (ID-TIMS) has been developed. This method consists of sequential sample and spike loading, ID-TIMS for isotopic measurement, and application of a series of mathematical procedures to remove the contribution of uranium in the spike. The homogeneity of evaporation and ionization of uranium content was confirmed by the consistent ratio of n((233)U)/n((238)U) determined by TIMS measurements. Verification of the method was performed using U030 solution droplets and U030 particles. Good agreements of resulting uranium quantity, n((235)U)/n((238)U), and n((236)U)/n((238)U) with the estimated or certified values showed the validity of this newly developed method for particle analysis when simultaneous determination of the quantity and isotopic ratios of uranium is required. Copyright © 2016 Elsevier B.V. All rights reserved.
Trans-Himalayan water contributions to river discharge
NASA Astrophysics Data System (ADS)
Andermann, Christoff; Stieglitz, Thomas; Schuessler, Jan A.; Parajouli, Binod
2017-04-01
Hydrological processes in high mountains are not well understood. Groundwater is commonly considered to be of little importance in the mountain water balance, while direct runoff, snow and ice melt are thought to be the principal hydrological buffer. We present new insights into hydrological fluxes between major reservoirs in a trans-Himalayan catchment. The study area is the Kali Gandaki catchment, rising in the dry Tibetan interior, carving through the high Himalayas and draining the full width of the foothills to the Ganges foreland. The catchment has a well-defined monsoon climate, with pronounced annual wet and dry seasons and a clear separation of wind- and leeward regions. We have sampled the main river and its tributaries as well as several springs during the four hydrological seasons (winter, pre-monsoon, monsoon, post-monsoon). We have measured major element abundances as well as 222Rn in situ, as a tracer for groundwater contribution. These measurements are placed in a context of topographic analyses as well as continuous discharge and precipitation measurements. Furthermore, we have equipped two sites with continuous water samplers, sampling over > 4 monsoon seasons, allowing us to resolve the seasonal hydrological dynamic range on a very high temporal resolution. Chemical fluxes vary spatially over several orders of magnitude, showing a systematic downstream dilution trend for most major elements during all hydrological seasons. High initial concentrations derive from evaporite deposits in the uppermost part of the catchment, constituting a large scale, natural salt tracer experiment. The well-defined decline of solute concentrations along the main river, paired with constraints on the composition of lateral water inputs downstream allow the calculation of the spatial distribution of additional hydrological fluxes, by applying end member mixing modeling. Continuous river stage and bulk dissolved load (electrical conductivity) monitoring depict well-defined diurnal cycles in water temperature, stage level and water chemistry. These diurnal cycles have a profound impact on the chemical concentrations and need to be corrected for to estimate representative geochemical fluxes for the full river and end member mixing modeling. Radon and trace element data indicate that groundwater contributions are primarily associated with the main tectonic structures of the Himalayan range, but also concentrate on the steep southern mountain front, and that groundwater outflow from the Lesser Himalayas is limited during baseflow season. Over the seasons the chemical dilution signature across the Himalayan range is persistent. However, specific elements have temporally distinct dilution signatures highlighting the alternating contribution of different hydrological compartments over the annual hydrological cycle. Our analysis allows to decipher the hydrological contribution of different water reservoirs to the surface water discharge in rivers, along a major Himalayan stream. Our results highlight the volumetric importance of a high mountain deep-groundwater storage compartment across the Himalayan mountain belt and provides first order quantification of groundwater contribution to stream flow.
Rotor for processing liquids using movable capillary tubes
Johnson, W.F.; Burtis, C.A.; Walker, W.A.
1987-07-17
A rotor assembly for processing liquids, especially whole blood samples, is disclosed. The assembly includes apparatus for separating non-liquid components of whole blood samples from liquid components, apparatus for diluting the separated liquid component with a diluent and apparatus for transferring the diluted sample to an external apparatus for analysis. The rotor assembly employs several movable capillary tubes to handle the sample and diluents. A method for using the rotor assembly to process liquids is also described. 5 figs.
Organic cleanliness of the Mars Science Laboratory sample transfer chain.
Blakkolb, B; Logan, C; Jandura, L; Okon, A; Anderson, M; Katz, I; Aveni, G; Brown, K; Chung, S; Ferraro, N; Limonadi, D; Melko, J; Mennella, J; Yavrouian, A
2014-07-01
One of the primary science goals of the Mars Science Laboratory (MSL) Rover, Curiosity, is the detection of organics in Mars rock and regolith. To achieve this, the Curiosity rover includes a robotic sampling system that acquires rock and regolith samples and delivers it to the Sample Analysis at Mars (SAM) instrument on board the rover. In order to provide confidence that any significant organics detection result was Martian and not terrestrial in origin, a requirement was levied on the flight system (i.e., all sources minus the SAM instrument) to impart no more than 36 parts per billion (ppb by weight) of total reduced carbon terrestrial contamination to any sample transferred to the SAM instrument. This very clean level was achieved by a combination of a rigorous contamination control program on the project, and then using the first collected samples for a "dilution cleaning" campaign of the sample chain prior to delivering a sample to the SAM instrument. Direct cleanliness assays of the sample-contacting and other Flight System surfaces during pre-launch processing were used as inputs to determine the number of dilution cleaning samples needed once on Mars, to enable delivery of suitably clean samples to the SAM experiment. Taking into account contaminant redistribution during launch thorough landing of the MSL on Mars, the amount of residue present on the sampling hardware prior to the time of first dilution cleaning sample acquisition was estimated to be 60 ng/cm(2) on exposed outer surfaces of the sampling hardware and 20 ng/cm(2) on internal sample contacting surfaces; residues consisting mainly of aliphatic hydrocarbons and esters. After three dilution cleaning samples, estimated in-sample contamination level for the first regolith sample delivered to the SAM instrument at the Gale Crater "Rocknest" site was bounded at ≤10 ppb total organic carbon. A Project decision to forego ejecting the dilution cleaning sample and instead transfer the first drill-acquired sample at the "John Klein" site to SAM resulted in an estimated level of terrestrial contamination of ≤430 ppb. The estimated terrestrial contamination for portions from the second drill-acquired sample, at Cumberland, was ≤69 ppb; the estimate for a future, third, drilled sample is ≤38 ppb. These levels are comparable in magnitude to the SAM instrument blanks at the nanomole level (as chlorohydrocarbon).
Dilution of protein-surfactant complexes: a fluorescence study.
Azadi, Glareh; Chauhan, Anuj; Tripathi, Anubhav
2013-09-01
Dilution of protein-surfactant complexes is an integrated step in microfluidic protein sizing, where the contribution of free micelles to the overall fluorescence is reduced by dilution. This process can be further improved by establishing an optimum surfactant concentration and quantifying the amount of protein based on the fluorescence intensity. To this end, we study the interaction of proteins with anionic sodium dodecyl sulfate (SDS) and cationic hexadecyl trimethyl ammonium bromide (CTAB) using a hydrophobic fluorescent dye (sypro orange). We analyze these interactions fluourometrically with bovine serum albumin, carbonic anhydrase, and beta-galactosidase as model proteins. The fluorescent signature of protein-surfactant complexes at various dilution points shows three distinct regions, surfactant dominant, breakdown, and protein dominant region. Based on the dilution behavior of protein-surfactant complexes, we propose a fluorescence model to explain the contribution of free and bound micelles to the overall fluorescence. Our results show that protein peak is observed at 3 mM SDS as the optimum dilution concentration. Furthermore, we study the effect of protein concentration on fluorescence intensity. In a single protein model with a constant dye quantum yield, the peak height increases with protein concentration. Finally, addition of CTAB to the protein-SDS complex at mole fractions above 0.1 shifts the protein peak from 3 mM to 4 mM SDS. The knowledge of protein-surfactant interactions obtained from these studies provides significant insights for novel detection and quantification techniques in microfluidics. © 2013 The Protein Society.
40 CFR 1065.546 - Validation of minimum dilution ratio for PM batch sampling.
Code of Federal Regulations, 2012 CFR
2012-07-01
... chemical balance terms as given in § 1065.655(e). You may determine the raw exhaust flow rate based on the measured intake air and dilute exhaust molar flow rates and the dilute exhaust chemical balance terms as... air, fuel rate measurements, and fuel properties, consistent with good engineering judgment. (b...
40 CFR 1065.546 - Validation of minimum dilution ratio for PM batch sampling.
Code of Federal Regulations, 2013 CFR
2013-07-01
... chemical balance terms as given in § 1065.655(e). You may determine the raw exhaust flow rate based on the measured intake air and dilute exhaust molar flow rates and the dilute exhaust chemical balance terms as... air, fuel rate measurements, and fuel properties, consistent with good engineering judgment. (b...
40 CFR 1065.546 - Verification of minimum dilution ratio for PM batch sampling.
Code of Federal Regulations, 2014 CFR
2014-07-01
... chemical balance terms as given in § 1065.655(e). You may determine the raw exhaust flow rate based on the measured intake air and dilute exhaust molar flow rates and the dilute exhaust chemical balance terms as... air, fuel rate measurements, and fuel properties, consistent with good engineering judgment. (b...
USDA-ARS?s Scientific Manuscript database
Mobile humic acid (MHA) and calcium humate (CaHA) are humic fractions sequentially extracted from soil samples. MHA is extracted by dilute NaOH, and CaHA is subsequently extracted by dilute NaOH from the dilute HCl-washed soil residues of the first extraction. This chapter reviews the recent advance...
ERIC Educational Resources Information Center
Pety, Stephen J.; Lu, Hang; Thio, Yonathan S.
2011-01-01
This paper describes a student laboratory experiment to determine the molecular weight of a polymer sample by measuring the viscosity of dilute polymer solutions in a PDMS microfluidic viscometer. Sample data are given for aqueous solutions of poly(ethylene oxide) (PEO). A demonstration of shear thinning behavior using the microviscometer is…
Depth matters: Soil pH and dilution effects in the northern Great Plains
USDA-ARS?s Scientific Manuscript database
In the northern Great Plans (NGP), surface sampling depths of 0-15.2 cm or 0-20.3 cm are suggested for testing soil characteristics such as pH. However, acidification is often most pronounced near-surface (e.g., <10 cm). Thus, sampling deeper can potentially dilute (increase) pH measurements and the...
Chang, Victor W C; Hildemann, Lynn M; Chang, Cheng-hisn
2009-06-01
The particle and gaseous pollutants in vehicle exhaust emissions undergo rapid dilution with ambient air after exiting the tailpipe. The rate and extent of this dilution can greatly affect both the size evolution of primary exhaust particles and the potential for formation of ultrafine particles. Dilution ratios were measured inside of a wind tunnel in the region immediately downstream of the tailpipe using model vehicles (approximately one-fifth to one-seventh scale models) representing a light-duty truck, a passenger car, and a heavy-duty tractor head (without the trailer). A tracer gas (ethene) was released at a measured flow rate from the tailpipe, and 60 sampling probes placed downstream of the vehicle simultaneously sampled gas tracer concentrations in the near-wake (first few vehicle heights) and far-wake regions (beyond 10 vehicle heights). Tests using different tunnel wind speeds show the range of dilution ratios that can be expected as a function of vehicle type and downstream distance (i.e., time). The vehicle shape quite strongly influences dilution profiles in the near-wake region but is much less important in the far-wake region. The tractor generally produces higher dilution rates than the automobile and light-duty truck under comparable conditions.
Kitchen, A D; Newham, J A
2011-05-01
Whilst some of the assays used for serological screening of post-mortem blood samples from deceased tissue donors in some countries have been specifically validated by the manufacturer for this purpose, a significant number of those currently in use globally have not. Although specificity has previously been considered a problem in the screening of such samples, we believe that ensuring sensitivity is more important. The aim of this study was to validate a broader range of assays for the screening of post-mortem blood samples from deceased tissue donors. Six microplate immunoassays currently in use within National Health Service Blood and Transplant (NHSBT) for the screening of blood, tissue and stem cell donations were included. Representative samples from confirmed positive donors were titrated in screen negative post-mortem samples in parallel with normal pooled negative serum to determine if there was any inhibition with the post-mortem samples. There were no significant differences seen (P < 0.005) between the dilution curves obtained for the positive samples diluted in post-mortem samples and normal pooled sera. Although small numbers of samples were studied, it can be surmised that the post-mortem blood samples from deceased tissue donors, collected according to United Kingdom guidelines, are a suitable substrate for the assays evaluated. No diminution of reactivity was seen when dilution with sera from deceased donors was compared to dilution using pooled serum from live donors. In the absence of genuine low titre positive post-mortem samples, the use of samples spiked with various levels of target material provides a means of qualifying serological screening assays used by NHSBT for the screening of post-mortem blood samples from deceased tissue donors.
Automated fluid analysis apparatus and techniques
Szecsody, James E.
2004-03-16
An automated device that couples a pair of differently sized sample loops with a syringe pump and a source of degassed water. A fluid sample is mounted at an inlet port and delivered to the sample loops. A selected sample from the sample loops is diluted in the syringe pump with the degassed water and fed to a flow through detector for analysis. The sample inlet is also directly connected to the syringe pump to selectively perform analysis without dilution. The device is airtight and used to detect oxygen-sensitive species, such as dithionite in groundwater following a remedial injection to treat soil contamination.
Identification of Key Odorants in Withering-Flavored Green Tea by Aroma Extract Dilution Analysis
NASA Astrophysics Data System (ADS)
Mizukami, Yuzo; Yamaguchi, Yuichi
This research aims to identify key odorants in withering-flavored green tea. Application of the aroma extract dilution analysis using the volatile fraction of green tea and withering-flavored green tea revealed 25 and 35 odor-active peaks with the flavor dilution factors of≥4, respectively. 4-mercapto-4-methylpentan-2-one, (E)-2-nonenal, linalool, (E,Z)-2,6-nonadienal and 3-methylnonane-2,4-dione were key odorants in green tea with the flavor dilution factor of≥16. As well as these 5 odorants, 1-octen-3-one, β-damascenone, geraniol, β-ionone, (Z)-methyljasmonate, indole and coumarine contributed to the withering flavor of green tea.
Pisciotta, John M.; Rath, Damon F.; Stanek, Paul A.; Flanery, D. Michael; Harwood, Valerie J.
2002-01-01
The Colilert-18 system for enumeration of total coliforms and Escherichia coli is approved by the U.S. Environmental Protection Agency for use in drinking water analysis and is also used by various agencies and research studies for enumeration of indicator organisms in fresh and saline waters. During monitoring of Pinellas County, Fla., marine waters, estimates of E. coli numbers (by Colilert-18) frequently exceeded fecal coliform counts (by membrane filtration) by 1 to 3 orders of magnitude. Samples from freshwater sites did not display similar discrepancies. Fecal coliforms, including E. coli, could be cultured from 100% of yellow fluorescent wells (denoting E. coli-positive results) inoculated with freshwater samples but could be cultured from only 17.1% of the “positive” wells inoculated with marine samples. Ortho-nitrophenyl-β-d-galactopyranoside (ONPG)-positive or 4-methylumbelliferyl-β-d-glucuronide (MUG)-positive noncoliform bacteria were readily cultured from Colilert-18 test wells inoculated with marine samples. Filtered cell-free seawater did not cause false positives. Coculture preparations of as few as 5 CFU of Vibrio cholerae (ONPG positive) and Providencia sp. (MUG positive) ml−1 inoculated into Colilert-18 caused false-positive E. coli results. Salinity conditions influenced coculture results, as the concentration of coculture inoculum required to cause false positives in most wells increased from about 5 CFU ml−1 in seawater diluted 1:10 with freshwater to ≈5,000 CFU ml−1 in seawater diluted 1:20 with freshwater. Estimated E. coli numbers in various marine water samples processed at the 1:10 dilution ranged from 10 to 7,270 CFU·100 ml−1, while E. coli numbers in the same samples processed at the 1:20 dilution did not exceed 40 CFU·100 ml−1. The lower estimates of E. coli numbers corresponded well with fecal coliform counts by membrane filtration. This study indicates that assessment of E. coli in subtropical marine waters by Colilert-18 is not accurate when the recommended 1:10 sample dilution is used. The results suggest that greater dilution may diminish the false-positive problem, but further study of this possibility is recommended. PMID:11823188
Mechanistic investigations in sono-hybrid techniques for rice straw pretreatment.
Suresh, Kelothu; Ranjan, Amrita; Singh, Shuchi; Moholkar, Vijayanand S
2014-01-01
This paper reports comparative study of two chemical techniques (viz. dilute acid/alkali treatment) and two physical techniques (viz. hot water bath and autoclaving) coupled with sonication, termed as sono-hybrid techniques, for hydrolysis of rice straw. The efficacy of each sono-hybrid technique was assessed on the basis of total sugar and reducing sugar release. The system of biomass pretreatment is revealed to be mass transfer controlled. Higher sugar release is obtained during dilute acid treatment than dilute alkali treatment. Autoclaving alone was found to increase sugar release marginally as compared to hot water bath. Sonication of the biomass solution after autoclaving and stirring resulted in significant rise of sugar release, which is attributed to strong convection generated during sonication that assists effective transport of sugar molecules. Discrimination between individual contributions of ultrasound and cavitation to mass transfer enhancement reveals that contribution of ultrasound (through micro-streaming) is higher. Micro-turbulence as well as acoustic waves generated by cavitation did not contribute much to enhancing of mass transfer in the system. Copyright © 2013 Elsevier B.V. All rights reserved.
Verifying mixing in dilution tunnels How to ensure cookstove emissions samples are unbiased
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wilson, Daniel L.; Rapp, Vi H.; Caubel, Julien J.
A well-mixed diluted sample is essential for unbiased measurement of cookstove emissions. Most cookstove testing labs employ a dilution tunnel, also referred to as a “duct,” to mix clean dilution air with cookstove emissions before sampling. It is important that the emissions be well-mixed and unbiased at the sampling port so that instruments can take representative samples of the emission plume. Some groups have employed mixing baffles to ensure the gaseous and aerosol emissions from cookstoves are well-mixed before reaching the sampling location [2, 4]. The goal of these baffles is to to dilute and mix the emissions stream withmore » the room air entering the fume hood by creating a local zone of high turbulence. However, potential drawbacks of mixing baffles include increased flow resistance (larger blowers needed for the same exhaust flow), nuisance cleaning of baffles as soot collects, and, importantly, the potential for loss of PM2.5 particles on the baffles themselves, thus biasing results. A cookstove emission monitoring system with baffles will collect particles faster than the duct’s walls alone. This is mostly driven by the available surface area for deposition by processes of Brownian diffusion (through the boundary layer) and turbophoresis (i.e. impaction). The greater the surface area available for diffusive and advection-driven deposition to occur, the greater the particle loss will be at the sampling port. As a layer of larger particle “fuzz” builds on the mixing baffles, even greater PM2.5 loss could occur. The micro structure of the deposited aerosol will lead to increased rates of particle loss by interception and a tendency for smaller particles to deposit due to impaction on small features of the micro structure. If the flow stream could be well-mixed without the need for baffles, these drawbacks could be avoided and the cookstove emissions sampling system would be more robust.« less
40 CFR 1065.170 - Batch sampling for gaseous and PM constituents.
Code of Federal Regulations, 2014 CFR
2014-07-01
... collecting and storing PM on a filter. You may use batch sampling to store emissions that have been diluted.... As another example, do not use PM filters that irreversibly absorb or adsorb gases to the extent that... must follow the requirements in § 1065.140(e)(2) related to PM dilution ratios. For each filter, if you...
40 CFR 1065.170 - Batch sampling for gaseous and PM constituents.
Code of Federal Regulations, 2013 CFR
2013-07-01
... collecting and storing PM on a filter. You may use batch sampling to store emissions that have been diluted... another example, do not use PM filters that irreversibly absorb or adsorb gases to the extent that it... follow the requirements in § 1065.140(e)(2) related to PM dilution ratios. For each filter, if you expect...
40 CFR 1065.170 - Batch sampling for gaseous and PM constituents.
Code of Federal Regulations, 2012 CFR
2012-07-01
... collecting and storing PM on a filter. You may use batch sampling to store emissions that have been diluted... another example, do not use PM filters that irreversibly absorb or adsorb gases to the extent that it... follow the requirements in § 1065.140(e)(2) related to PM dilution ratios. For each filter, if you expect...
40 CFR 1065.170 - Batch sampling for gaseous and PM constituents.
Code of Federal Regulations, 2010 CFR
2010-07-01
... collecting and storing PM on a filter. You may use batch sampling to store emissions that have been diluted... another example, do not use PM filters that irreversibly absorb or adsorb gases to the extent that it... follow the requirements in § 1065.140(e)(2) related to PM dilution ratios. For each filter, if you expect...
40 CFR 1065.170 - Batch sampling for gaseous and PM constituents.
Code of Federal Regulations, 2011 CFR
2011-07-01
... collecting and storing PM on a filter. You may use batch sampling to store emissions that have been diluted... another example, do not use PM filters that irreversibly absorb or adsorb gases to the extent that it... follow the requirements in § 1065.140(e)(2) related to PM dilution ratios. For each filter, if you expect...
Sperm DNA fragmentation in boars is delayed or abolished by using sperm extenders.
Pérez-Llano, Begoña; Enciso, María; García-Casado, Pedro; Sala, Rubén; Gosálvez, Jaime
2006-12-01
The semen quality of seven young adult boars was assessed for percentages of sperm motility, normal acrosomes, abnormal sperm, cells positive to sHOST (short Hipoosmotic Swelling Test), HPNA cells (sHOST Positive with Normal Acrosome cells) and the percentage of sperm heads, which exhibited DNA fragmentation using the Sperm Chromatin Dispersion test (SCD). These parameters were analysed in sperm samples both undiluted and diluted using a commercial extender and stored at 15 degrees C for 21 days. Results showed that semen quality decreases faster in the undiluted semen samples from day 0 to day 7 compared to diluted semen samples that remained with a high quality up to day 11. The undiluted semen exhibited a low DNA fragmentation index (DFI) during the first days and then a significant increase from day 7 up to day 21. This increase in the DFI coincided with the lowest levels of the other semen quality parameters. On the contrary, the samples diluted in the commercial extender showed very low levels of DNA fragmentation in all boars during the preservation period. When the evolution of DNA fragmentation was analysed in the undiluted samples, differences were found among boars. These differences were not shown in the samples diluted in the extender where the basal DFI remained stable during the 21 days. The main conclusion of this study was that some sperm extenders delay or partially prevent sperm DNA fragmentation.
Measurement of plasma unbound unconjugated bilirubin.
Ahlfors, C E
2000-03-15
A method is described for measuring the unconjugated fraction of the unbound bilirubin concentration in plasma by combining the peroxidase method for determining unbound bilirubin with a diazo method for measuring conjugated and unconjugated bilirubin. The accuracy of the unbound bilirubin determination is improved by decreasing sample dilution, eliminating interference by conjugated bilirubin, monitoring changes in bilirubin concentration using diazo derivatives, and correcting for rate-limiting dissociation of bilirubin from albumin. The unbound unconjugated bilirubin concentration by the combined method in plasma from 20 jaundiced newborns was significantly greater than and poorly correlated with the unbound bilirubin determined by the existing peroxidase method (r = 0.7), possibly due to differences in sample dilution between the methods. The unbound unconjugated bilirubin was an unpredictable fraction of the unbound bilirubin in plasma samples from patients with similar total bilirubin concentrations but varying levels of conjugated bilirubin. A bilirubin-binding competitor was readily detected at a sample dilution typically used for the combined test but not at the dilution used for the existing peroxidase method. The combined method is ideally suited to measuring unbound unconjugated bilirubin in jaundiced human newborns or animal models of kernicterus. Copyright 2000 Academic Press.
Woebken, Dagmar; Burow, Luke C; Behnam, Faris; Mayali, Xavier; Schintlmeister, Arno; Fleming, Erich D; Prufert-Bebout, Leslie; Singer, Steven W; Cortés, Alejandro López; Hoehler, Tori M; Pett-Ridge, Jennifer; Spormann, Alfred M; Wagner, Michael; Weber, Peter K; Bebout, Brad M
2015-01-01
Photosynthetic microbial mats are complex, stratified ecosystems in which high rates of primary production create a demand for nitrogen, met partially by N2 fixation. Dinitrogenase reductase (nifH) genes and transcripts from Cyanobacteria and heterotrophic bacteria (for example, Deltaproteobacteria) were detected in these mats, yet their contribution to N2 fixation is poorly understood. We used a combined approach of manipulation experiments with inhibitors, nifH sequencing and single-cell isotope analysis to investigate the active diazotrophic community in intertidal microbial mats at Laguna Ojo de Liebre near Guerrero Negro, Mexico. Acetylene reduction assays with specific metabolic inhibitors suggested that both sulfate reducers and members of the Cyanobacteria contributed to N2 fixation, whereas 15N2 tracer experiments at the bulk level only supported a contribution of Cyanobacteria. Cyanobacterial and nifH Cluster III (including deltaproteobacterial sulfate reducers) sequences dominated the nifH gene pool, whereas the nifH transcript pool was dominated by sequences related to Lyngbya spp. Single-cell isotope analysis of 15N2-incubated mat samples via high-resolution secondary ion mass spectrometry (NanoSIMS) revealed that Cyanobacteria were enriched in 15N, with the highest enrichment being detected in Lyngbya spp. filaments (on average 4.4 at% 15N), whereas the Deltaproteobacteria (identified by CARD-FISH) were not significantly enriched. We investigated the potential dilution effect from CARD-FISH on the isotopic composition and concluded that the dilution bias was not substantial enough to influence our conclusions. Our combined data provide evidence that members of the Cyanobacteria, especially Lyngbya spp., actively contributed to N2 fixation in the intertidal mats, whereas support for significant N2 fixation activity of the targeted deltaproteobacterial sulfate reducers could not be found. PMID:25303712
Woebken, Dagmar; Burow, Luke C.; Behnam, Faris; ...
2014-10-10
Photosynthetic microbial mats are complex, stratified ecosystems in which high rates of primary production create a demand for nitrogen, met partially by N 2 fixation. Dinitrogenase reductase ( nifH) genes and transcripts from Cyanobacteria and heterotrophic bacteria (for example, Deltaproteobacteria) were detected in these mats, yet their contribution to N 2 fixation is poorly understood. We used a combined approach of manipulation experiments with inhibitors, nifH sequencing and single-cell isotope analysis to investigate the active diazotrophic community in intertidal microbial mats at Laguna Ojo de Liebre near Guerrero Negro, Mexico. Acetylene reduction assays with specific metabolic inhibitors suggested that bothmore » sulfate reducers and members of the Cyanobacteria contributed to N 2 fixation, whereas 15N 2 tracer experiments at the bulk level only supported a contribution of Cyanobacteria. Cyanobacterial and nifH Cluster III (including deltaproteobacterial sulfate reducers) sequences dominated the nifH gene pool, whereas the nifH transcript pool was dominated by sequences related to Lyngbya spp. Single-cell isotope analysis of 15N 2-incubated mat samples via high-resolution secondary ion mass spectrometry (NanoSIMS) revealed that Cyanobacteria were enriched in 15N, with the highest enrichment being detected in Lyngbya spp. filaments (on average 4.4 at% 15N), whereas the Deltaproteobacteria (identified by CARD-FISH) were not significantly enriched. We investigated the potential dilution effect from CARD-FISH on the isotopic composition and concluded that the dilution bias was not substantial enough to influence our conclusions. As a result, our combined data provide evidence that members of the Cyanobacteria, especially Lyngbya spp., actively contributed to N 2 fixation in the intertidal mats, whereas support for significant N 2 fixation activity of the targeted deltaproteobacterial sulfate reducers could not be found.« less
Seraglio, Siluana Katia Tischer; Valese, Andressa Camargo; Daguer, Heitor; Bergamo, Greici; Azevedo, Mônia Stremel; Gonzaga, Luciano Valdemiro; Fett, Roseane; Costa, Ana Carolina Oliveira
2016-09-01
A simple, reproducible and sensitive method has been optimized and validated for simultaneous determination of 32 phenolic compounds in bracatinga (Mimosa scabrella Benth.) with the diluted-and-shoot approach, without the need of any additional clean-up steps. It has been based on high performance liquid chromatography coupled with triple quadrupole tandem mass spectrometry and electrospray ionization (HPLC-ESI-MS/MS). The chromatography conditions were optimized, and due to the selectivity provided by MRM monitoring, LC separation required only 9min. The developed method was validated on the basis of Eurachem and European Commission Decision 2002/657/EC guidelines. Mean recoveries ranged from 70.4 to 110%. Intra-day and inter-day precision with RSD (relative standard deviations) from 0.14 to 18.9% and 0.34 to 20.0%, respectively were achieved. Limits of detection (LOD) and quantification (LOQ) ranged from 0.03 to 3.20μgL -1 and 0.20-12.8μgL -1 . Finally, the method was applied to samples and 20 phenolic compounds were quantified in all the samples analyzed, representing a contribution to the characterization and quantification of phenolic compounds from bracatinga (M. scabrella Bentham) honeydew honey. Copyright © 2016 Elsevier Ltd. All rights reserved.
AW-101 entrained solids - Solubility versus temperature
DOE Office of Scientific and Technical Information (OSTI.GOV)
GJ Lumetta; RC Lettau; GF Piepel
This report describes the results of a test conducted by Battelle to assess the solubility of the solids entrained in the diluted AW-101 low-activity waste (LAW) sample. BNFL requested Battelle to dilute the AW-1-1 sample using de-ionized water to mimic expected plant operating conditions. BNFL further requested Battelle to assess the solubility of the solids present in the diluted AW-101 sample versus temperature conditions of 30, 40, and 50 C. BNFL requested these tests to assess the composition of the LAW supernatant and solids versus expected plant-operating conditions. The work was conducted according to test plan BNFL-TP-29953-7, Rev. 0, Determinationmore » of the Solubility of LAW Entrained Solids. The test went according to plan, with no deviations from the test plan.« less
Study of the dislocation contribution to the internal friction background of gold
NASA Astrophysics Data System (ADS)
Baur, J.; Benoit, W.
1987-04-01
The dislocation contribution to the internal friction (IF) background is studied in annealed gold samples containing various dilute concentrations of platinum impurities. The measurements are performed in the kHz frequency range in order to determine the loss mechanism responsible for the high IF background observed at these low frequencies. To this end, the IF background was systematically measured as a function of frequency, vibration amplitude, temperature, and impurity concentration. The experimental results show that the high dislocation contribution observed in annealed samples is strain-amplitude independent for amplitudes in the range 10-7 to 2×10-6, but rapidly decreases for amplitudes smaller than 10-7. In particular, the dislocation contribution tends to zero when the strain amplitude tends to zero. Furthermore, this contribution is frequency independent. These observations demonstrate that the dislocation contribution cannot be explained by relaxations. In particular, this contribution cannot be attributed to a viscous damping of the dislocation motion. On the contrary, the experiments show that the IF background due to dislocations must be explained by hysteretic and athermal motions of dislocations interacting with point defects. However, these hysteretic motions are not due to breakaway of dislocations from pinning points distributed along their length. The experimental results can be explained by the presence of point defects close to the dislocations, but not on them. The mechanical energy loss is attributed to hysteretic motions of dislocations between potential minima created by point defects.
Chaudhary, Amrita; Bag, Swarnendu; Mandal, Mousumi; Krishna Karri, Sri Phani; Barui, Ananya; Rajput, Monika; Banerjee, Provas; Sheet, Debdoot; Chatterjee, Jyotirmoy
2015-05-26
In traditional medicines honey is known for healing efficacy and vividly used as "Anupan" in Ayurvedic medicines appreciating roles in dilutions. Validating efficacy of physico-chemically characterized honey in dilutions, studies on in vitro wound healing and attainment of cellular confluence epithelial cells including expressions of cardinal genes is crucial. To evaluate effects of characterized honey in varied dilutions on cellular viability, in vitro wound healing and modulation of prime epithelial gene expressions. Six Indian honey-samples from different sources were physico-chemically characterized and optimal one was explored in dilutions (v/v%) through in vitro studies on human epithelial (HaCaT) cells for viability, wound healing and expressions of genes p63, E-cadherin, β-catenin, GnT-III and GnT-V. Studied honey samples (i.e. A-F) depicted range of pH (2-4), water (12.48-23.95), electrical conductivity (2.57-14.34), carbohydrate (68.73-98.65), protein (.316-5.36) and antioxidant potential. Though sample A and F showed physico-chemical proximity, but overall bio-impact of the earlier was better, thus studied in 8-.1% (v/v) dilution range. Four dilutions (.01, .04, .1, .25 v/v%) augmented cellular viability but in vitro wound healing was fastest (p<.05) under .1%. Such efficacy was further documented for p63 up-regulation by immunocytochemistry and mRNA studies. The E-cadherin and β-catenin mRNA-expressions were also up-regulated and their proteins were predominantly cytoplasmic. E-cadherin up-regulation was corroborative with down-regulation and up-regulation of GnT-III and GnT-V respectively. Present study illustrated efficacy of particular honey dilution (.1%) with characteristic free radical scavenging activity in facilitating cell proliferation and attainment of confluence towards faster wound healing and modulation of cardinal epithelial genes (viz. p63, E-cadherin, β-catenin, Gnt-III and V). Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Dilution space ratio of 2H and 18O of doubly labeled water method in humans.
Sagayama, Hiroyuki; Yamada, Yosuke; Racine, Natalie M; Shriver, Timothy C; Schoeller, Dale A
2016-06-01
Variation of the dilution space ratio (Nd/No) between deuterium ((2)H) and oxygen-18 ((18)O) impacts the calculation of total energy expenditure (TEE) by doubly labeled water (DLW). Our aim was to examine the physiological and methodological sources of variation of Nd/No in humans. We analyzed data from 2,297 humans (0.25-89 yr old). This included the variables Nd/No, total body water, TEE, body mass index (BMI), and percent body fat (%fat). To differentiate between physiologic and methodologic sources of variation, the urine samples from 54 subjects were divided and blinded and analyzed separately, and repeated DLW dosing was performed in an additional 55 participants after 6 mo. Sex, BMI, and %fat did not significantly affect Nd/No, for which the interindividual SD was 0.017. The measurement error from the duplicate urine sample sets was 0.010, and intraindividual SD of Nd/No in repeats experiments was 0.013. An additional SD of 0.008 was contributed by calibration of the DLW dose water. The variation of measured Nd/No in humans was distributed within a small range and measurement error accounted for 68% of this variation. There was no evidence that Nd/No differed with respect to sex, BMI, and age between 1 and 80 yr, and thus use of a constant value is suggested to minimize the effect of stable isotope analysis error on calculation of TEE in the DLW studies in humans. Based on a review of 103 publications, the average dilution space ratio is 1.036 for individuals between 1 and 80 yr of age. Copyright © 2016 the American Physiological Society.
40 CFR 86.110-90 - Exhaust gas sampling system; diesel vehicles.
Code of Federal Regulations, 2010 CFR
2010-07-01
... probe. The sensor shall have an accuracy and precision of ±2 °F (1.1 °C). (14) The dilute exhaust gas... probe. The sensor shall have an accuracy and precision of ±2 °F (1.1 °C). (14) The dilute exhaust gas... 40 Protection of Environment 18 2010-07-01 2010-07-01 false Exhaust gas sampling system; diesel...
40 CFR 86.110-90 - Exhaust gas sampling system; diesel vehicles.
Code of Federal Regulations, 2011 CFR
2011-07-01
... probe. The sensor shall have an accuracy and precision of ±2 °F (1.1 °C). (14) The dilute exhaust gas... probe. The sensor shall have an accuracy and precision of ±2 °F (1.1 °C). (14) The dilute exhaust gas... 40 Protection of Environment 18 2011-07-01 2011-07-01 false Exhaust gas sampling system; diesel...
Impact of asymmetrical flow field-flow fractionation on protein aggregates stability.
Bria, Carmen R M; Williams, S Kim Ratanathanawongs
2016-09-23
The impact of asymmetrical flow field-flow fractionation (AF4) on protein aggregate species is investigated with the aid of multiangle light scattering (MALS) and dynamic light scattering (DLS). The experimental parameters probed in this study include aggregate stability in different carrier liquids, shear stress (related to sample injection), sample concentration (during AF4 focusing), and sample dilution (during separation). Two anti-streptavidin (anti-SA) IgG1 samples composed of low and high molar mass (M) aggregates are subjected to different AF4 conditions. Aggregates suspended and separated in phosphate buffer are observed to dissociate almost entirely to monomer. However, aggregates in citric acid buffer are partially stable with dissociation to 25% and 5% monomer for the low and high M samples, respectively. These results demonstrate that different carrier liquids change the aggregate stability and low M aggregates can behave differently than their larger counterparts. Increasing the duration of the AF4 focusing step showed no significant changes in the percent monomer, percent aggregates, or the average Ms in either sample. Syringe-induced shear related to sample injection resulted in an increase in hydrodynamic diameter (dh) as measured by batch mode DLS. Finally, calculations showed that dilution during AF4 separation is significantly lower than in size exclusion chromatography with dilution occurring mainly at the AF4 channel outlet and not during the separation. This has important ramifications when analyzing aggregates that rapidly dissociate (<∼2s) upon dilution as the size calculated by AF4 theory may be more accurate than that measured by online DLS. Experimentally, the dhs determined by online DLS generally agreed with AF4 theory except for the more well retained larger aggregates for which DLS showed smaller sizes. These results highlight the importance of using AF4 retention theory to understand the impacts of dilution on analytes. Copyright © 2016 Elsevier B.V. All rights reserved.
Whole genome amplification and real-time PCR in forensic casework
Giardina, Emiliano; Pietrangeli, Ilenia; Martone, Claudia; Zampatti, Stefania; Marsala, Patrizio; Gabriele, Luciano; Ricci, Omero; Solla, Gianluca; Asili, Paola; Arcudi, Giovanni; Spinella, Aldo; Novelli, Giuseppe
2009-01-01
Background WGA (Whole Genome Amplification) in forensic genetics can eliminate the technical limitations arising from low amounts of genomic DNA (gDNA). However, it has not been used to date because any amplification bias generated may complicate the interpretation of results. Our aim in this paper was to assess the applicability of MDA to forensic SNP genotyping by performing a comparative analysis of genomic and amplified DNA samples. A 26-SNPs TaqMan panel specifically designed for low copy number (LCN) and/or severely degraded genomic DNA was typed on 100 genomic as well as amplified DNA samples. Results Aliquots containing 1, 0.1 and 0.01 ng each of 100 DNA samples were typed for a 26-SNPs panel. Similar aliquots of the same DNA samples underwent multiple displacement amplification (MDA) before being typed for the same panel. Genomic DNA samples showed 0% PCR failure rate for all three dilutions, whilst the PCR failure rate of the amplified DNA samples was 0% for the 1 ng and 0.1 ng dilutions and 0.077% for the 0.01 ng dilution. The genotyping results of both the amplified and genomic DNA samples were also compared with reference genotypes of the same samples obtained by direct sequencing. The genomic DNA samples showed genotype concordance rates of 100% for all three dilutions while the concordance rates of the amplified DNA samples were 100% for the 1 ng and 0.1 ng dilutions and 99.923% for the 0.01 ng dilution. Moreover, ten artificially-degraded DNA samples, which gave no results when analyzed by current forensic methods, were also amplified by MDA and genotyped with 100% concordance. Conclusion We investigated the suitability of MDA material for forensic SNP typing. Comparative analysis of amplified and genomic DNA samples showed that a large number of SNPs could be accurately typed starting from just 0.01 ng of template. We found that the MDA genotyping call and accuracy rates were only slightly lower than those for genomic DNA. Indeed, when 10 pg of input DNA was used in MDA, we obtained 99.923% concordance, indicating a genotyping error rate of 1/1299 (7.7 × 10-4). This is quite similar to the genotyping error rate of STRs used in current forensic analysis. Such efficiency and accuracy of SNP typing of amplified DNA suggest that MDA can also generate large amounts of genome-equivalent DNA from a minimal amount of input DNA. These results show for the first time that MDA material is suitable for SNP-based forensic protocols and in general when samples fail to give interpretable STR results. PMID:19366436
Novel method for on-road emission factor measurements using a plume capture trailer.
Morawska, L; Ristovski, Z D; Johnson, G R; Jayaratne, E R; Mengersen, K
2007-01-15
The method outlined provides for emission factor measurements to be made for unmodified vehicles driving under real world conditions at minimal cost. The method consists of a plume capture trailer towed behind a test vehicle. The trailer collects a sample of the naturally diluted plume in a 200 L conductive bag and this is delivered immediately to a mobile laboratory for subsequent analysis of particulate and gaseous emissions. The method offers low test turnaround times with the potential to complete much larger numbers of emission factor measurements than have been possible using dynamometer testing. Samples can be collected at distances up to 3 m from the exhaust pipe allowing investigation of early dilution processes. Particle size distribution measurements, as well as particle number and mass emission factor measurements, based on naturally diluted plumes are presented. A dilution profile relating the plume dilution ratio to distance from the vehicle tail pipe for a diesel passenger vehicle is also presented. Such profiles are an essential input for new mechanistic roadway air quality models.
Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio
2017-02-01
Diluting a sample to obtain a measure within the analytical range is a common task in clinical laboratories. However, for urgent samples, it can cause delays in test reporting, which can put patients' safety at risk. The aim of this work is to show a simple artificial neural network that can be used to make it unnecessary to predilute a sample using the information available through the laboratory information system. Particularly, the Multilayer Perceptron neural network built on a data set of 16,106 cardiac troponin I test records produced a correct inference rate of 100% for samples not requiring predilution and 86.2% for those requiring predilution. With respect to the inference reliability, the most relevant inputs were the presence of a cardiac event or surgery and the result of the previous assay. Therefore, such an artificial neural network can be easily implemented into a total automation framework to sensibly reduce the turnaround time of critical orders delayed by the operation required to retrieve, dilute, and retest the sample.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Bannochie, C. J.
2015-09-17
The Savannah River National Laboratory (SRNL) was tasked with preparing and shipping samples for Hg speciation by Eurofins Frontier Global Sciences, Inc. in Seattle, WA on behalf of the Savannah River Remediation (SRR) Mercury Task Team.i,ii The tenth shipment of samples was designated to include Modular Caustic Side Solvent Extraction Unit (MCU) Strip Effluent Hold Tank (SEHT) and MCU Decontaminated Salt Solution Hold Tank (DSSHT) materials from processing Salt Batch 7b. The MCU SEHT (MCU-15-722) and DSSHT (MCU-15-709) samples were pulled on June 15, 2015. All MCU samples were received at SRNL on June 16, 2015. The DSSHT sample wasmore » moved the same day to refrigeration, while the SEHT sample was placed in the Shielded Cells. On July 9, 2015 it was opened and an aliquot diluted 1:100 with Eurofins deionized water and a portion of the diluted sample transferred to a Teflon® bottle prior to moving it to refrigeration that same day. All samples were kept in the dark and refrigerated until final dilutions were prepared for shipment to Eurofins.« less
Santa, Cátia; Anjo, Sandra I; Manadas, Bruno
2016-07-01
Proteomic approaches are extremely valuable in many fields of research, where mass spectrometry methods have gained an increasing interest, especially because of the ability to perform quantitative analysis. Nonetheless, sample preparation prior to mass spectrometry analysis is of the utmost importance. In this work, two protein precipitation approaches, widely used for cleaning and concentrating protein samples, were tested and compared in very diluted samples solubilized in a strong buffer (containing SDS). The amount of protein recovered after acetone and TCA/acetone precipitation was assessed, as well as the protein identification and relative quantification by SWATH-MS yields were compared with the results from the same sample without precipitation. From this study, it was possible to conclude that in the case of diluted samples in denaturing buffers, the use of cold acetone as precipitation protocol is more favourable than the use of TCA/acetone in terms of reproducibility in protein recovery and number of identified and quantified proteins. Furthermore, the reproducibility in relative quantification of the proteins is even higher in samples precipitated with acetone compared with the original sample. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Volatile and key odourant compounds of Turkish Berberis crataegina fruit using GC-MS-Olfactometry.
Sonmezdag, Ahmet Salih; Kelebek, Hasim; Selli, Serkan
2018-04-01
This research was conducted to identify the aroma and aroma-active compounds of Berberis crataegina for the first time. Volatile profile of B. crataegina was obtained using the purge and trap extraction method with dichloromethane. Gas chromatography was coupled to mass spectrometry (GC-MS) allowed the quantitative and qualitative detection of 22 compounds in the sample. Aldehydes were the main chemical group in the sample and followed by aromatic alcohols and lactone. Aroma extract dilution analysis was implemented for the specification of key odourants of B. crataegina. In total, eight key odourants were detected in the extract of the sample, using GC-MS-Olfactometry and aldehydes were the leading chemical group. The key odourants, found to be contributing to the overall aroma in B. crataegina, were nonanal (FD = 1024; green, flowery), hexanal (FD = 512; green) and linalool (FD = 256; flowery, rose) because of high FD factors.
Quantitation of DNA adducts by stable isotope dilution mass spectrometry
Tretyakova, Natalia; Goggin, Melissa; Janis, Gregory
2012-01-01
Exposure to endogenous and exogenous chemicals can lead to the formation of structurally modified DNA bases (DNA adducts). If not repaired, these nucleobase lesions can cause polymerase errors during DNA replication, leading to heritable mutations potentially contributing to the development of cancer. Due to their critical role in cancer initiation, DNA adducts represent mechanism-based biomarkers of carcinogen exposure, and their quantitation is particularly useful for cancer risk assessment. DNA adducts are also valuable in mechanistic studies linking tumorigenic effects of environmental and industrial carcinogens to specific electrophilic species generated from their metabolism. While multiple experimental methodologies have been developed for DNA adduct analysis in biological samples – including immunoassay, HPLC, and 32P-postlabeling – isotope dilution high performance liquid chromatography-electrospray ionization-tandem mass spectrometry (HPLC-ESI-MS/MS) generally has superior selectivity, sensitivity, accuracy, and reproducibility. As typical DNA adducts concentrations in biological samples are between 0.01 – 10 adducts per 108 normal nucleotides, ultrasensitive HPLC-ESI-MS/MS methodologies are required for their analysis. Recent developments in analytical separations and biological mass spectrometry – especially nanoflow HPLC, nanospray ionization MS, chip-MS, and high resolution MS – have pushed the limits of analytical HPLC-ESI-MS/MS methodologies for DNA adducts, allowing researchers to accurately measure their concentrations in biological samples from patients treated with DNA alkylating drugs and in populations exposed to carcinogens from urban air, drinking water, cooked food, alcohol, and cigarette smoke. PMID:22827593
Radioisotope dilution analyses of geological samples using 236U and 229Th
Rosholt, J.N.
1984-01-01
The use of 236U and 229Th in alpha spectrometric measurements has some advantages over the use of other tracers and measurement techniques in isotope dilution analyses of most geological samples. The advantages are: (1) these isotopes do not occur in terrestrial rocks, (2) they have negligible decay losses because of their long half lives, (3) they cause minimal recoil contamination to surface-barrier detectors, (4) they allow for simultaneous determination of the concentration and isotopic composition of uranium and thorium in a variety of sample types, and (5) they allow for simple and constant corrections for spectral inferences, 0.5% of the 238U activity is subtracted for the contribution of 235U in the 236U peak and 1% of the 229Th activity is subtracted from the 230Th activity. Disadvantages in using 236U and 229Th are: (1) individual separates of uranium and thorium must be prepared as very thin sources for alpha spectrometry, (2) good resolution in the spectrometer system is required for thorium isotopic measurements where measurement times may extend to 300 h, and (3) separate calibrations of the 236U and 229Th spike solution with both uranium and thorium standards are required. The use of these tracers in applications of uranium-series disequilibrium studies has simplified the measurements required for the determination of the isotopic composition of uranium and thorium because of the minimal corrections needed for alpha spectral interferences. ?? 1984.
Zhang, Yan; Liu, Jun W; Zheng, Wen J; Wang, Lei; Zhang, Hong Y; Fang, Guo Z; Wang, Shuo
2008-02-01
In this study, an enzyme-linked immunosorbent assay (ELISA) was optimized and applied to the determination of endosulfan residues in 20 different kinds of food commodities including vegetables, dry fruits, tea and meat. The limit of detection (IC(15)) was 0.8 microg kg(-1) and the sensitivity (IC(50)) was 5.3 microg kg(-1). Three simple extraction methods were developed, including shaking on the rotary shaker at 250 r min(-1) overnight, shaking on the rotary shaker for 1 h and thoroughly mixing for 2 min. Methanol was used as the extraction solvent in this study. The extracts were diluted in 0.5% fish skin gelatin (FG) in phosphate-buffered saline (PBS) at various dilutions in order to remove the matrix interference. For cabbage (purple and green), asparagus, Japanese green, Chinese cabbage, scallion, garland chrysanthemum, spinach and garlic, the extracts were diluted 10-fold; for carrots and tea, the extracts were diluted 15-fold and 900-fold, respectively. The extracts of celery, adzuki beans and chestnuts, were diluted 20-fold to avoid the matrix interference; ginger, vegetable soybean and peanut extracts were diluted 100-fold; mutton and chicken extracts were diluted 10-fold and for eel, the dilution was 40-fold. Average recoveries were 63.13-125.61%. Validation was conducted by gas chromatography (GC) and gas chromatography-mass spectrometry (GC-MS). The results of this study will be useful to the wide application of an ELISA for the rapid determination of pesticides in food samples.
New methods allowing the detection of protein aggregates
Demeule, Barthélemy; Palais, Caroline; Machaidze, Gia; Gurny, Robert
2009-01-01
Aggregation compromises the safety and efficacy of therapeutic proteins. According to the manufacturer, the therapeutic immunoglobulin trastuzumab (Herceptin®) should be diluted in 0.9% sodium chloride before administration. Dilution in 5% dextrose solutions is prohibited. The reason for the interdiction is not mentioned in the Food and Drug Administration (FDA) documentation, but the European Medicines Agency (EMEA) Summary of Product Characteristics states that dilution of trastuzumab in dextrose solutions results in protein aggregation. In this paper, asymmetrical flow field-flow fractionation (FFF), fluorescence spectroscopy, fluorescence microscopy and transmission electron microscopy (TEM) have been used to characterize trastuzumab samples diluted in 0.9% sodium chloride, a stable infusion solution, as well as in 5% dextrose (a solution prone to aggregation). When trastuzumab samples were injected in the FFF channel using a standard separation method, no difference could be seen between trastuzumab diluted in sodium chloride and trastuzumab diluted in dextrose. However, during FFF measurements made with appropriate protocols, aggregates were detected in 5% dextrose. The parameters enabling the detection of reversible trastuzumab aggregates are described. Aggregates could also be documented by fluorescence microscopy and TEM. Fluorescence spectroscopy data were indicative of conformational changes consistent with increased aggregation and adsorption to surfaces. The analytical methods presented in this study were able to detect and characterize trastuzumab aggregates. PMID:20061815
Lubin, Arnaud; Sheng, Sheng; Cabooter, Deirdre; Augustijns, Patrick; Cuyckens, Filip
2017-11-17
Lack of knowledge on the expected concentration range or insufficient linear dynamic range of the analytical method applied are common challenges for the analytical scientist. Samples that are above the upper limit of quantification are typically diluted and reanalyzed. The analysis of undiluted highly concentrated samples can cause contamination of the system, while the dilution step is time consuming and as the case for any sample preparation step, also potentially leads to precipitation, adsorption or degradation of the analytes. Copyright © 2017 Elsevier B.V. All rights reserved.
García-González, Diego L; Sedman, Jacqueline; van de Voort, Frederik R
2013-04-01
Spectral reconstitution (SR) is a dilution technique developed to facilitate the rapid, automated, and quantitative analysis of viscous oil samples by Fourier transform infrared spectroscopy (FT-IR). This technique involves determining the dilution factor through measurement of an absorption band of a suitable spectral marker added to the diluent, and then spectrally removing the diluent from the sample and multiplying the resulting spectrum to compensate for the effect of dilution on the band intensities. The facsimile spectrum of the neat oil thus obtained can then be qualitatively or quantitatively analyzed for the parameter(s) of interest. The quantitative performance of the SR technique was examined with two transition-metal carbonyl complexes as spectral markers, chromium hexacarbonyl and methylcyclopentadienyl manganese tricarbonyl. The estimation of the volume fraction (VF) of the diluent in a model system, consisting of canola oil diluted to various extents with odorless mineral spirits, served as the basis for assessment of these markers. The relationship between the VF estimates and the true volume fraction (VF(t)) was found to be strongly dependent on the dilution ratio and also depended, to a lesser extent, on the spectral resolution. These dependences are attributable to the effect of changes in matrix polarity on the bandwidth of the ν(CO) marker bands. Excellent VF(t) estimates were obtained by making a polarity correction devised with a variance-spectrum-delineated correction equation. In the absence of such a correction, SR was shown to introduce only a minor and constant bias, provided that polarity differences among all the diluted samples analyzed were minimal. This bias can be built into the calibration of a quantitative FT-IR analytical method by subjecting appropriate calibration standards to the same SR procedure as the samples to be analyzed. The primary purpose of the SR technique is to simplify preparation of diluted samples such that only approximate proportions need to be adhered to, rather than using exact weights or volumes, the marker accounting for minor variations. Additional applications discussed include the use of the SR technique in extraction-based, quantitative, automated FT-IR methods for the determination of moisture, acid number, and base number in lubricating oils, as well as of moisture content in edible oils.
Development of reproducible assays for polygalacturonase and pectinase.
Li, Qian; Coffman, Anthony M; Ju, Lu-Kwang
2015-05-01
Polygalacturonase and pectinase activities reported in the literature were measured by several different procedures. These procedures do not give comparable results, partly owing to the complexity of the substrates involved. This work was aimed at developing consistent and efficient assays for polygalacturonase and pectinase activities, using polygalacturonic acid and citrus pectin, respectively, as the substrate. Different enzyme mixtures produced by Aspergillus niger and Trichoderma reesei with different inducing carbon sources were used for the method development. A series of experiments were conducted to evaluate the incubation time, substrate concentration, and enzyme dilution. Accordingly, for both assays the recommended (optimal) hydrolysis time is 30min and substrate concentration is 5g/L. For polygalacturonase, the sample should be adjusted to have 0.3-0.8U/mL polygalacturonase activity, because in this range the assay outcomes were consistent (independent of dilution factors). Such a range did not exist for the pectinase assay. The recommended procedure is to assay the sample at multiple (at least 2) dilution factors and determine, by linear interpolation, the dilution factor that would release reducing sugar equivalent to 0.4g/L d-galacturonic acid, and then calculate the activity of the sample accordingly (dilution factor×0.687U/mL). Validation experiments showed consistent results using these assays. Effects of substrate preparation methods were also examined. Copyright © 2015 Elsevier Inc. All rights reserved.
Cao, Y; Griffith, J F; Dorevitch, S; Weisberg, S B
2012-07-01
Draft criteria for the optional use of qPCR for recreational water quality monitoring have been published in the United States. One concern is that inhibition of the qPCR assay can lead to false-negative results and potentially inadequate public health protection. We evaluate the effectiveness of strategies for minimizing the impact of inhibition. Five qPCR method permutations for measuring Enterococcus were challenged with 133 potentially inhibitory fresh and marine water samples. Serial dilutions were conducted to assess Enterococcus target assay inhibition, to which inhibition identified using four internal controls (IC) was compared. The frequency and magnitude of inhibition varied considerably among qPCR methods, with the permutation using an environmental master mix performing substantially better. Fivefold dilution was also effective at reducing inhibition in most samples (>78%). ICs were variable and somewhat ineffective, with 54-85% agreement between ICs and serial dilution. The current IC methods appear to not accurately predict Enterococcus inhibition and should be used with caution; fivefold dilution and the use of reagents designed for environmental sample analysis (i.e. more robust qPCR chemistry) may be preferable. Suitable approaches for defining, detecting and reducing inhibition will improve implementation of qPCR for water monitoring. © 2012 The Authors. Journal of Applied Microbiology © 2012 The Society for Applied Microbiology.
Amorphous silicon research. Final technical progress report, 1 August 1994--28 February 1998
DOE Office of Scientific and Technical Information (OSTI.GOV)
Guha, S
1998-05-01
This report describes the status and accomplishments of work performed under this subcontract by United Solar Systems. United Solar researchers explored several new deposition regimes/conditions to investigate their effect on material/device performance. To facilitate optimum ion bombardment during growth, a large parameter space involving chamber pressure, rf power, and hydrogen dilution were investigated. United Solar carried out a series of experiments using discharge modulation at various pulsed-plasma intervals to study the effect of Si-particle incorporation on solar cell performance. Hydrogen dilution during deposition is found to improve both the initial and stable performance of a-Si and a-SiGe alloy cells. Researchersmore » conducted a series of temperature-ramping experiments on samples prepared with high and low hydrogen dilutions to study the effect of hydrogen effusion on solar cell performance. Using an internal photoemission method, the electrical bandgap of a microcrystalline p layer used in high-efficiency solar cells was measured to be 1.6 eV. New measurement techniques were developed to evaluate the interface and bulk contributions of losses to solar cell performance. Researchers replaced hydrogen with deuterium and found deuterated amorphous silicon alloy solar cells exhibit reduced light-induced degradation. The incorporation of a microcrystalline n layer in a multijunction cell is seen to improve cell performance. United Solar achieved a world-record single-junction a-Si alloy stable cell efficiency of 9.2% with an active area of 0.25 cm{sup 2} grown with high hydrogen dilution. They also achieved a world-record triple-junction, stable, active-area cell efficiency of 13.0% with an active area of 0.25 cm{sup 2}.« less
Ialongo, Cristiano; Pieri, Massimo; Bernardini, Sergio
2017-02-01
Saving resources is a paramount issue for the modern laboratory, and new trainable as well as smart technologies can be used to allow the automated instrumentation to manage samples more efficiently in order to achieve streamlined processes. In this regard the serum free light chain (sFLC) testing represents an interesting challenge, as it usually causes using a number of assays before achieving an acceptable result within the analytical range. An artificial neural network based on the multi-layer perceptron (MLP-ANN) was used to infer the starting dilution status of sFLC samples based on the information available through the laboratory information system (LIS). After the learning phase, the MLP-ANN simulation was applied to the nephelometric testing routinely performed in our laboratory on a BN ProSpec® System analyzer (Siemens Helathcare) using the N Latex FLC kit. The MLP-ANN reduced the serum kappa free light chain (κ-FLC) and serum lambda free light chain (λ-FLC) wasted tests by 69.4% and 70.8% with respect to the naïve stepwise dilution scheme used by the automated analyzer, and by 64.9% and 66.9% compared to a "rational" dilution scheme based on a 4-step dilution. Although it was restricted to follow-up samples, the MLP-ANN showed good predictive performance, which alongside the possibility to implement it in any automated system, made it a suitable solution for achieving streamlined laboratory processes and saving resources.
Morris, Bari R; deLaforcade, Armelle; Lee, Joyce; Palmisano, Joseph; Meola, Dawn; Rozanski, Elizabeth
2016-01-01
To investigate the effects of in vitro hemodilution with lactated Ringers solution (LRS), hetastarch (HES), and fresh frozen plasma (FFP) on whole blood coagulation in dogs as assessed by kaolin-activated thromboelastography. In vitro experimental study. University teaching hospital. Six healthy client-owned dogs. Whole blood was collected and diluted in vitro at a 33% and 67% dilution with either LRS, HES, or FFP. Kaolin-activated thromboelastography was performed on each sample as well as a control. Thromboelastographic parameters R (min), alpha (deg), K (min), and MA (mm) were measured and compared to the sample control for each dilution using mixed model methodology. Prolongation in coagulation times were seen at both dilutions with LRS and HES. There was no significant difference in R times at the 33% dilution, but R time was significantly prolonged at the 67% dilution with HES (P = 0.004). MA was significantly decreased for LRS at both dilutions (P = 0.013, P < 0.001) and more profoundly decreased for HES (P < 0.001, P = 0.006). No significant difference in any parameter was found for FFP. In vitro hemodilution of whole blood with both LRS and HES but not FFP resulted in significant effects on coagulation with HES having a more profound effect. In vivo evaluation of changes in coagulation with various resuscitation fluids is warranted and may be clinically relevant. © Veterinary Emergency and Critical Care Society 2015.
Turick, C.E.; Apel, W.W.
1997-10-28
A method of reducing the concentration of Cr(VI) in a liquid aqueous residue comprises the steps of providing anaerobic Cr(VI) reducing bacteria, mixing the liquid aqueous residue with a nutrient medium to form a mixture, and contacting the mixture with the anaerobic Cr(VI) reducing bacteria such that Cr(VI) is reduced to Cr(III). The anaerobic Cr(VI) reducing bacteria appear to be ubiquitous in soil and can be selected by collecting a soil sample, diluting the soil sample with a sterile diluent to form a diluted sample, mixing the diluted sample with an effective amount of a nutrient medium and an effective amount of Cr(VI) to form a mixture, and incubating the mixture in the substantial absence of oxygen such that growth of Cr(VI) sensitive microorganisms is inhibited and growth of the anaerobic Cr(VI) reducing bacteria is stimulated. A method of in situ bioremediation of Cr(VI) contaminated soil and/or groundwater is also disclosed. 10 figs.
Turick, Charles E.; Apel, William W.
1997-10-28
A method of reducing the concentration of Cr(VI) in a liquid aqueous residue comprises the steps of providing anaerobic Cr(VI) reducing bacteria, mixing the liquid aqueous residue with a nutrient medium to form a mixture, and contacting the mixture with the anaerobic Cr(VI) reducing bacteria such that Cr(VI) is reduced to Cr(III). The anaerobic Cr(VI) reducing bacteria appear to be ubiquitous in soil and can be selected by collecting a soil sample, diluting the soil sample with a sterile diluent to form a diluted sample, mixing the diluted sample with an effective amount of a nutrient medium and an effective amount of Cr(VI) to form a mixture, and incubating the mixture in the substantial absence of oxygen such that growth of Cr(VI) sensitive microorganisms is inhibited and growth of the anaerobic Cr(VI) reducing bacteria is stimulated. A method of in situ bioremediation of Cr(VI) contaminated soil and/or groundwater is also disclosed.
NASA Astrophysics Data System (ADS)
Peña-Vázquez, E.; Barciela-Alonso, M. C.; Pita-Calvo, C.; Domínguez-González, R.; Bermejo-Barrera, P.
2015-09-01
The objective of this work is to develop a method for the determination of metals in saline matrices using high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). Module SFS 6 for sample injection was used in the manual mode, and flame operating conditions were selected. The main absorption lines were used for all the elements, and the number of selected analytical pixels were 5 (CP±2) for Cd, Cu, Fe, Ni, Pb and Zn, and 3 pixels for Mn (CP±1). Samples were acidified (0.5% (v/v) nitric acid), and the standard addition method was used for the sequential determination of the analytes in diluted samples (1:2). The method showed good precision (RSD(%) < 4%, except for Pb (6.5%)) and good recoveries. Accuracy was checked after the analysis of an SPS-WW2 wastewater reference material diluted with synthetic seawater (dilution 1:2), showing a good agreement between certified and experimental results.
Márta, Zoltán; Bobály, Balázs; Fekete, Jenő; Magda, Balázs; Imre, Tímea; Mészáros, Katalin Viola; Szabó, Pál Tamás
2016-09-10
Ultratrace analysis of sample components requires excellent analytical performance in terms of limits of quantitation (LoQ). Micro UHPLC coupling with sensitive tandem mass spectrometry provides state of the art solutions for such analytical problems. Decreased column volume in micro LC limits the injectable sample volume. However, if analyte concentration is extremely low, it might be necessary to inject high sample volumes. This is particularly critical for strong sample solvents and weakly retained analytes, which are often the case when preparing biological samples (protein precipitation, sample extraction, etc.). In that case, high injection volumes may cause band broadening, peak distortion or even elution in dead volume. In this study, we evaluated possibilities of high volume injection onto microbore RP-LC columns, when sample solvent is diluted. The presented micro RP-LC-MS/MS method was optimized for the analysis of steroid hormones from human plasma after protein precipitation with organic solvents. A proper sample dilution procedure helps to increase the injection volume without compromising peak shapes. Finally, due to increased injection volume, the limit of quantitation can be decreased by a factor of 2-5, depending on the analytes and the experimental conditions. Copyright © 2016 Elsevier B.V. All rights reserved.
San, Anh T; Joyce, Daryl C; Hofman, Peter J; Macnish, Andrew J; Webb, Richard I; Matovic, Nicolas J; Williams, Craig M; De Voss, James J; Wong, Siew H; Smyth, Heather E
2017-04-15
Reported herein is a high throughput method to quantify in a single analysis the key volatiles that contribute to the aroma of commercially significant mango cultivars grown in Australia. The method constitutes stable isotope dilution analysis (SIDA) in conjunction with headspace (HS) solid-phase microextraction (SPME) coupled with gas-chromatography mass spectrometry (GCMS). Deuterium labelled analogues of the target analytes were either purchased commercially or synthesised for use as internal standards. Seven volatiles, hexanal, 3-carene, α-terpinene, p-cymene, limonene, α-terpinolene and ethyl octanoate, were targeted. The resulting calibration functions had determination coefficients (R 2 ) ranging from 0.93775 to 0.99741. High recovery efficiencies for spiked mango samples were also achieved. The method was applied to identify the key aroma volatile compounds produced by 'Kensington Pride' and 'B74' mango fruit and by 'Honey Gold' mango sap. This method represents a marked improvement over current methods for detecting and measuring concentrations of mango fruit and sap volatiles. Copyright © 2016 Elsevier Ltd. All rights reserved.
Optical gain in 1.3-μm electrically driven dilute nitride VCSOAs
2014-01-01
We report the observation of room-temperature optical gain at 1.3 μm in electrically driven dilute nitride vertical cavity semiconductor optical amplifiers. The gain is calculated with respect to injected power for samples with and without a confinement aperture. At lower injected powers, a gain of almost 10 dB is observed in both samples. At injection powers over 5 nW, the gain is observed to decrease. For nearly all investigated power levels, the sample with confinement aperture gives slightly higher gain. PMID:24417791
Can low-temperature thermoluminescence cast light on the nature of ultra-high dilutions?
Rey, Louis
2007-07-01
Low-temperature thermoluminescence has been used in attempt to understand the particular structure of ultra high dilutions. Samples are activated by irradiation after freezing at the temperature of liquid nitrogen (77 degrees K). Experimental results show that, in the course of rewarming, the thermoluminescent glow is susbtantially different between dilutions of different substances. It is suggested that the dispersed gas phase might play a role in this process.
Cipriano, R.C.; Bullock, G.L.
2001-01-01
In vitro studies indicated that commercially prepared transport systems containing Amies, Stuart's, and Cary-Blair media worked equally well in sustaining the viability of the fish pathogen Aeromonas salmonicida, which causes furunculosis. The bacterium remained viable without significant increase or decrease in cell numbers for as long as 48 h of incubation at 18-20??C in Stuart's transport medium; consequently, obtaining mucus samples in such tubes were comparable to on-site detection of A. salmonicida by dilution plate counts on Coomassie Brilliant Blue agar. In three different assays of 100 samples of mucus from Atlantic salmon Salmo salar infected subclinically with A. salmonicida, dilution counts conducted on-site proved more reliable for detecting the pathogen than obtaining the samples in the transport system. In the on-site assays, dilution counts detected the pathogen in 34, 41, and 22 samples, whereas this was accomplished in only 15, 15, and 3 of the respective samples when the transport system was used. In an additional experiment, Arctic char Salvelinus alpinus sustaining a frank epizootic of furunculosis were sampled similarly. Here, too, dilution counts were more predictive of the prevalence of A. salmonicida and detected the pathogen in 46 mucus samples; in comparison, only 6 samples collected by using the transport system were positive. We also observed that the transport system supported the growth of the normal mucus bacterial flora. Particularly predominant among these were motile aeromonads and Pseudomonas fluorescens. In studies of mixed culture growth, two representatives of both of the latter genera of bacteria outgrew A. salmonicida - in some cases, to the total exclusion of the pathogen itself.
NASA Astrophysics Data System (ADS)
Palmer, M. R.; Arata, C.; Huang, K.
2014-12-01
Nitrous oxide (N2O) gas is among the major contributors to global warming and ozone depletion in stratosphere. Quantitative estimate of N2O production in various pathways and N2O fluxes across different reservoirs is the key to understanding the role of N2O in the global change. To achieve this goal, accurate and concurrent measurement of both N2O concentration ([N2O]) and its site-specific isotopic composition (SP-δ15N), namely δ15Nα and δ15Nβ, is desired. Recent developments in Cavity Ring-Down Spectroscopy (CRDS) have enabled high precision measurements of [N2O] and SP-δ15N of a continuous gas flow. However, many N2O samples are discrete with limited volume (< 500 ml), and/or high [N2O] (> 2 ppm), and are not suitable for direct measurements by CRDS. Here we present results of a Small Sample Isotope Module 2 (SSIM2) which is coupled to and automatically coordinated with a Picarro isotopic N2O CRDS analyzer to handle and measure high concentration and/or small volume samples. The SSIM2 requires 20 ml of sample per analysis, and transfers the sample to the CRDS for high precision measurement. When the sample injection is < 20 ml, a zero gas is optionally filled to make up the volume. We used the SSIM2 to dilute high [N2O] samples and < 20 ml samples, and tested the effect of dilution on the measured SP-δ15N. In addition, we employed and tested a newly developed double injection method for samples adequate for two 20 ml injections. After the SSIM2 and the CRDS cavity was primed with the first injection, the second injection, which has negligible dilution of the sample, can be accurately measured for both [N2O] and SP-δ15N. Results of these experiments indicate that the precision of SSIM2-CRDS is similar to that of the continuous measurements using the CRDS alone, and that dilution has minimal effect on SP-δ15N, as along as the [N2O] is > 300 ppb after dilution. Overall, the precision of SP-δ15N measured using the SSIM2 is < 0.5 ‰.
Alagandula, Ravali; Zhou, Xiang; Guo, Baochuan
2017-01-15
Liquid chromatography/tandem mass spectrometry (LC/MS/MS) is the gold standard of urine drug testing. However, current LC-based methods are time consuming, limiting the throughput of MS-based testing and increasing the cost. This is particularly problematic for quantification of drugs such as phenobarbital, which is often analyzed in a separate run because they must be negatively ionized. This study examined the feasibility of using a dilute-and-shoot flow-injection method without LC separation to quantify drugs with phenobarbital as a model system. Briefly, a urine sample containing phenobarbital was first diluted by 10 times, followed by flow injection of the diluted sample to mass spectrometer. Quantification and detection of phenobarbital were achieved by an electrospray negative ionization MS/MS system operated in the multiple reaction monitoring (MRM) mode with the stable-isotope-labeled drug as internal standard. The dilute-and-shoot flow-injection method developed was linear with a dynamic range of 50-2000 ng/mL of phenobarbital and correlation coefficient > 0.9996. The coefficients of variation and relative errors for intra- and inter-assays at four quality control (QC) levels (50, 125, 445 and 1600 ng/mL) were 3.0% and 5.0%, respectively. The total run time to quantify one sample was 2 min, and the sensitivity and specificity of the method did not deteriorate even after 1200 consecutive injections. Our method can accurately and robustly quantify phenobarbital in urine without LC separation. Because of its 2 min run time, the method can process 720 samples per day. This feasibility study shows that the dilute-and-shoot flow-injection method can be a general way for fast analysis of drugs in urine. Copyright © 2016 John Wiley & Sons, Ltd. Copyright © 2016 John Wiley & Sons, Ltd.
Further studies on rapid dilution and warming of boar semen.
Bamba, K; Cran, D G
1988-03-01
Studies have been carried out to investigate factors related to the induction of warm shock in boar spermatozoa. Rapid dilution per se caused visible damage to acrosomes when the sample contained 7.5% or more glycerol. This dilution effect was greater at lower temperatures. Acrosomal damage was greatly reduced by raising the dilution temperature from 15 to 25 degrees C, suggesting that a change in the physico-chemical characteristics of the acrosomal membrane occurred between these temperatures. During rapid dilution with warming, the dilution rate, the magnitude of the temperature change and the terminal temperature had a significant influence on acrosomal integrity; a terminal temperature of 35 degrees C was much more detrimental than one of 25 degrees C. The first sign of acrosomal damage was observed 15 sec after rapid dilution + warming and the damage was nearly maximal by 60 sec. An antioxidant, butylated hydroxytoluene (BHT), was effective against both rapid cooling and warming, while glycerol, dimethylsulphoxide and propylene glycol were ineffective in preventing warm shock.
ERIC Educational Resources Information Center
Hill, Devon W.; And Others
1988-01-01
Describes a laboratory technique for quantitative analysis of caffeine by an isotopic dilution method for coupled gas chromatography-mass spectroscopy. Discusses caffeine analysis and experimental methodology. Lists sample caffeine concentrations found in common products. (MVL)
40 CFR 86.527-90 - Test procedures, overview.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Section 86.527-90 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS... constant volume (variable dilution) sampler. (d) Except in cases of component malfunction or failure, all... emissions measurements are made. For exhaust testing, this requires sampling and analysis of the dilution...
Quantitative evaluation of analyte transport on microfluidic paper-based analytical devices (μPADs).
Ota, Riki; Yamada, Kentaro; Suzuki, Koji; Citterio, Daniel
2018-02-07
The transport efficiency during capillary flow-driven sample transport on microfluidic paper-based analytical devices (μPADs) made from filter paper has been investigated for a selection of model analytes (Ni 2+ , Zn 2+ , Cu 2+ , PO 4 3- , bovine serum albumin, sulforhodamine B, amaranth) representing metal cations, complex anions, proteins and anionic molecules. For the first time, the transport of the analytical target compounds rather than the sample liquid, has been quantitatively evaluated by means of colorimetry and absorption spectrometry-based methods. The experiments have revealed that small paperfluidic channel dimensions, additional user operation steps (e.g. control of sample volume, sample dilution, washing step) as well as the introduction of sample liquid wicking areas allow to increase analyte transport efficiency. It is also shown that the interaction of analytes with the negatively charged cellulosic paper substrate surface is strongly influenced by the physico-chemical properties of the model analyte and can in some cases (Cu 2+ ) result in nearly complete analyte depletion during sample transport. The quantitative information gained through these experiments is expected to contribute to the development of more sensitive μPADs.
Meyer, Michael T.; Loftin, Keith A.; Lee, Edward A.; Hinshaw, Gary H.; Dietze, Julie E.; Scribner, Elisabeth A.
2009-01-01
The U.S. Geological Survey method (0-2141-09) presented is approved for the determination of glyphosate, its degradation product aminomethylphosphonic acid (AMPA), and glufosinate in water. It was was validated to demonstrate the method detection levels (MDL), compare isotope dilution to standard addition, and evaluate method and compound stability. The original method USGS analytical method 0-2136-01 was developed using liquid chromatography/mass spectrometry and quantitation by standard addition. Lower method detection levels and increased specificity were achieved in the modified method, 0-2141-09, by using liquid chromatography/tandem mass spectrometry (LC/MS/MS). The use of isotope dilution for glyphosate and AMPA and pseudo isotope dilution of glufosinate in place of standard addition was evaluated. Stable-isotope labeled AMPA and glyphosate were used as the isotope dilution standards. In addition, the stability of glyphosate and AMPA was studied in raw filtered and derivatized water samples. The stable-isotope labeled glyphosate and AMPA standards were added to each water sample and the samples then derivatized with 9-fluorenylmethylchloroformate. After derivatization, samples were concentrated using automated online solid-phase extraction (SPE) followed by elution in-line with the LC mobile phase; the compounds separated and then were analyzed by LC/MS/MS using electrospray ionization in negative-ion mode with multiple-reaction monitoring. The deprotonated derivatized parent molecule and two daughter-ion transition pairs were identified and optimized for glyphosate, AMPA, glufosinate, and the glyphosate and AMPA stable-isotope labeled internal standards. Quantitative comparison between standard addition and isotope dilution was conducted using 473 samples analyzed between April 2004 and June 2006. The mean percent difference and relative standard deviation between the two quantitation methods was 7.6 plus or minus 6.30 (n = 179), AMPA 9.6 plus or minus 8.35 (n = 206), and glufosinate 9.3 plus or minus 9.16 (n = 16). The analytical variation of the method, comparison of quantitation by isotope dilution and multipoint linear regressed standard curves, and method detection levels were evaluated by analyzing six sets of distilled-water, groundwater, and surface-water samples spiked in duplicate at 0.0, 0.05, 0.10 and 0.50 microgram per liter and analyzed on 6 different days during 1 month. The grand means of the normalized concentration percentage recovery for glyphosate, AMPA, and glufosinate among all three matrices and spiked concentrations ranged from 99 to 114 plus or minus 2 to 7 percent of the expected spiked concentration. The grand mean of the percentage difference between concentrations calculated by standard addition and linear regressed multipoint standard curves ranged from 8 to 15 plus or minus 2 to 9 percent for the three compounds. The method reporting levels calculated from all the 0.05- microgram per liter spiked samples were 0.02 microgram per liter for all three compounds. Compound stability experiments were conducted on 10 samples derivatized four times for periods between 136 to 269 days. The glyphosate and AMPA concentrations remained relatively constant in samples held up to 136 days before derivatization. The half life of glyphosate varied from 169 to 223 days in the underivatized samples. Derivatized samples were analyzed the day after derivitization, and again 54 and 64 days after derivatization. The derivatized samples analyzed at days 52 and 64 were within 20 percent of the concentrations of the derivatized samples analyzed the day after derivatization.
Brunet, J L; Cozon, G; Sainte-Laudy, J; Boissel, J P; Delair, S; Peyramond, D
1997-10-01
By measuring the activation of different cell models (lymphocytes and lymphocytic subsets) in the presence of Candida albicans with flow cytometry reading, it is possible to show that successive dilutions of Candida albicans can lead to lymphocyte activation in abnormally-sensitized subjects. In a first trial, 10 subjects were tested in duplicate. The decrease of activity of the dilutions does not appear to be regular in relation to the progression of the dilutions. The activity of the dilutions wanes relatively rapidly with the first dilutions, then recurs later very distinctly, at the 6th dilution, then ebbs, then reappears in similar manner at the 9th, the 14th, and finally, the 19th dilution. Cell reactivity appears to differ depending on the subject. It can be represented through the calculated slope of the regression line, for each series of data. It therefore appears feasible to determine a threshold of reactivity and a scale of sensitivity, to make it possible to specify the degree of abnormal reactivity existing at a given time for a given subject. The constancy of the activity of the different dilutions tested, on 10 cultures of a single cell suspension, is especially well demonstrated in the second trial, showing unusually small standard deviations. Thus, the question arises as to the exact nature of the observed phenomenon and of its analysis from a physical-chemical point of view, with regard to the pharmacological effect of successive dilutions of Candida albicans.
Cremer, N E; Cossen, C K; Hanson, C V; Shell, G R
1982-01-01
Several methods for evaluating and reporting enzyme immunoassay (EIA) determinations of antibody to herpes simplex virus derived from one dilution of single serum samples were studied. An EIA ratio method for serological evidence of current infection from paired serum samples was also evaluated. Optical density (OD) of the reaction at a 1:100 serum dilution and estimated titers obtained by reference of the OD of the serum dilution to a standard curve were compared to the corresponding plotted EIA titer obtained by titration to endpoint. Neither the OD per se nor the estimated titer was completely predictive of the plotted titer (correlation coefficient [r] of 0.824 and 0.817, respectively), and they provided only a semiquantitative measurement of antibody concentration. For an antibody status report, however, OD would be sufficient if related to the cutoff value as an EIA index (OD of sample divided by cutoff OD for positive specimens). The OD of the EIA reaction at a single dilution (1:5) of cerebrospinal fluid, on the other hand, correlated quite well with the titer obtained by titration (r = 0.950). For serological diagnosis of current infection, the OD ratio of convalescence-phase/acute-phase sera was determined at several dilutions. A ratio of greater than or equal to 1.54 was calculated as a reliable index for a significant rise in antibody concentration and compatible with current infection. By determining the convalescent-phase/acute-phase serum ratio at two dilutions, 1:100 and 1:1,000, the EIA ratio method appeared to be a sensitive as or more sensitive than, complement fixation in diagnosing current infection. PMID:6284791
Loading and dilution: arsenic, sodium and nutrients in a section of the River Tisza, Hungary
NASA Astrophysics Data System (ADS)
Türk, Gábor; Prokisch, József; Simon, Edina; Szabó, Szilárd
2015-11-01
We aimed to reveal the risk of arsenic in a Hungarian river (the Tisza) at the mouth of a polluted canal. Four sampling sites were involved in this work and samples were collected on a weekly basis for arsenic and sodium, and on a monthly basis for nutrients. Significant differences were found concerning each studied component between the sampling locations of the River Tisza. Statistical analysis also revealed that the values of the upper and lower river tracts did not differ significantly. Thus, water carried by the canal is being diluted before it reaches the farthest sampling location.
Gaikowski, M.P.; Larson, W.J.; Steuer, J.J.; Gingerich, W.H.
2004-01-01
Accurate estimates of drug concentrations in hatchery effluent are critical to assess the environmental risk of hatchery drug discharge resulting from disease treatment. This study validated two dilution simple n models to estimate chloramine-T environmental introduction concentrations by comparing measured and predicted chloramine-T concentrations using the US Geological Survey's Upper Midwest Environmental Sciences Center aquaculture facility effluent as an example. The hydraulic characteristics of our treated raceway and effluent and the accuracy of our water flow rate measurements were confirmed with the marker dye rhodamine WT. We also used the rhodamine WT data to develop dilution models that would (1) estimate the chloramine-T concentration at a given time and location in the effluent system and (2) estimate the average chloramine-T concentration at a given location over the entire discharge period. To test our models, we predicted the chloramine-T concentration at two sample points based on effluent flow and the maintenance of chloramine-T at 20 mg/l for 60 min in the same raceway used with rhodamine WT. The effluent sample points selected (sample points A and B) represented 47 and 100% of the total effluent flow, respectively. Sample point B is-analogous to the discharge of a hatchery that does not have a detention lagoon, i.e. The sample site was downstream of the last dilution water addition following treatment. We then applied four chloramine-T flow-through treatments at 20mg/l for 60 min and measured the chloramine-T concentration in water samples collected every 15 min for about 180 min from the treated raceway and sample points A and B during and after application. The predicted chloramine-T concentration at each sampling interval was similar to the measured chloramine-T concentration at sample points A and B and was generally bounded by the measured 90% confidence intervals. The predicted aver,age chloramine-T concentrations at sample points A or B (2.8 and 1.3 mg/l, respectively) were not significantly different (P > 0.05) from the average measured chloramine-T concentrations (2.7 and 1.3 mg/l, respectively). The close agreement between our predicted and measured chloramine-T concentrations indicate either of the dilution models could be used to adequately predict the chloramine-T environmental introduction concentration in Upper Midwest Environmental Sciences Center effluent. (C) 2003 Elsevier B.V. All rights reserved.
Marashi-Najafi, F; Khalil-Allafi, J; Etminanfar, M R
2017-07-01
The present study deals with pulse electrochemical deposition of HA on NiTi alloy and in vitro evaluation of coatings. At first step, a thermo-chemical surface modification process was applied to control the Ni release of the alloy. The electrochemical deposition of CaP coatings was examined at both dilute and concentrated solutions. The morphology and the composition of coatings were studied using scanning electron microscopy (SEM) and Fourier transform infrared spectroscopy (FTIR). Plate like and needle like morphologies were formed for dilute and concentrated solution respectively and HA phase was formed by increasing the pulse current density for both electrolyte. The thickness of the samples was measured using cross sectioning technique. Fibroblast cell culture test on the coated samples revealed that the HA coating obtained by dilute solution shows the best biocompatibility. Also, MTT assay showed the highest cell density and cell proliferation after 5days for the HA coating of dilute solution. The contact angle of samples was measured and the coated samples showed a hydrophilic surface. Soaking the sample in SBF revealed that the crystallization rate of calcium-phosphate compounds is higher on the plate like HA coating as compared to the needle like morphology. The P release of the HA coated samples was measured in a physiological saline solution and the results show that the ions releasing in the plate like coating are less than the needle like coating. It seems that the stability of the plate like coating in biological environments is responsible for the better biocompatibility of the coating. Copyright © 2017 Elsevier B.V. All rights reserved.
Yang, Qi; Franco, Christopher M M; Zhang, Wei
2015-10-01
Experiments were designed to validate the two common DNA extraction protocols (CTAB-based method and DNeasy Blood & Tissue Kit) used to effectively recover actinobacterial DNA from sponge samples in order to study the sponge-associated actinobacterial diversity. This was done by artificially spiking sponge samples with actinobacteria (spores, mycelia and a combination of the two). Our results demonstrated that both DNA extraction methods were effective in obtaining DNA from the sponge samples as well as the sponge samples spiked with different amounts of actinobacteria. However, it was noted that in the presence of the sponge, the bacterial 16S rRNA gene could not be amplified unless the combined DNA template was diluted. To test the hypothesis that the extracted sponge DNA contained inhibitors, dilutions of the DNA extracts were tested for six sponge species representing five orders. The results suggested that the inhibitors were co-extracted with the sponge DNA, and a high dilution of this DNA was required for the successful PCR amplification for most of the samples. The optimized PCR conditions, including primer selection, PCR reaction system and program optimization, further improved the PCR performance. However, no single PCR condition was found to be suitable for the diverse sponge samples using various primer sets. These results highlight for the first time that the DNA extraction methods used are effective in obtaining actinobacterial DNA and that the presence of inhibitors in the sponge DNA requires high dilution coupled with fine tuning of the PCR conditions to achieve success in the study of sponge-associated actinobacterial diversity.
Harmonic decomposition of magneto-optical signal from suspensions of superparamagnetic nanoparticles
NASA Astrophysics Data System (ADS)
Patterson, Cody; Syed, Maarij; Takemura, Yasushi
2018-04-01
Magnetic nanoparticles (MNPs) are widely used in biomedical applications. Characterizing dilute suspensions of superparamagnetic iron oxide nanoparticles (SPIONs) in bio-relevant media is particularly valuable for magnetic particle imaging, hyperthermia, drug delivery, etc. Here, we study dilute aqueous suspensions of single-domain magnetite nanoparticles using an AC Faraday rotation (FR) setup. The setup uses an oscillating magnetic field (800 Hz) which generates a multi-harmonic response. Each harmonic is collected and analyzed using the Fourier components of the theoretical signal determined by a Langevin-like magnetization. With this procedure, we determine the average magnetic moment per particle μ , particle number density n, and Verdet constant of the sample. The fitted values of μ and n are shown to be consistent across each harmonic. Additionally, we present the results of these parameters as n is varied. The large values of μ reveal the possibility of clustering as reported in other literature. This suggests that μ is representative of the average magnetic moment per cluster of nanoparticles. Multiple factors, including the external magnetic field, surfactant degradation, and laser absorption, can contribute to dynamic and long-term aggregation leading to FR signals that represent space- and time-averaged sample parameters. Using this powerful analysis procedure, future studies are aimed at determining the clustering mechanisms in this AC system and characterizing SPION suspensions at different frequencies and viscosities.
Diluted thrombin time reliably measures low to intermediate plasma dabigatran concentrations.
Božič-Mijovski, Mojca; Malmström, Rickard E; Malovrh, Petra; Antovic, Jovan P; Vene, Nina; Šinigoj, Petra; Mavri, Alenka
2016-07-01
Direct oral anticoagulant dabigatran was first introduced as a fixed-dose drug without routine coagulation monitoring, but current recommendations suggest that diluted thrombin time can be used to estimate plasma drug level. The aim of this study was to assess a diluted thrombin time assay based on the same thrombin reagent already used for traditional thrombin time measurements that reliably measure low to intermediate plasma dabigatran levels. We included 44 patients with atrial fibrillation who started treatment with dabigatran 150 mg (23 patients) or 110 mg (21 patients) twice a day. Blood samples were collected at baseline (no dabigatran) and 2-4 weeks after the beginning of dabigatran therapy at trough and at peak. Plasma dabigatran levels were measured with diluted thrombin time and compared to liquid chromatography with tandem mass spectrometry as the reference method. The performance of the diluted thrombin time was compared to Hemoclot® Thrombin Inhibitor and Ecarin Chromogenic Assay. In ex vivo plasma samples, diluted thrombin time highly correlated with the liquid chromatography with tandem mass spectrometry (Pearson's R = 0.9799). In the low to intermediate range (dabigatran concentration ≤ 100 µg/L) diluted thrombin time correlated significantly more closely to the liquid chromatography with tandem mass spectrometry (R = 0.964) than Hemoclot® Thrombin Inhibitor (R = 0.935, p = 0.05) or Ecarin Chromogenic Assay (R = 0.915, p < 0.01). It was also the only functional assay without any significant bias in the low to intermediate range. Both trough and peak diluted thrombin time values were similar to liquid chromatography with tandem mass spectrometry. We conclude that the diluted thrombin time assay presented in this study reliably detects dabigatran and that it is superior to the Hemoclot® Thrombin Inhibitor assay in the low to intermediate range. © The Author(s) 2015.
Performance Evaluation of Particle Sampling Probes for Emission Measurements of Aircraft Jet Engines
NASA Technical Reports Server (NTRS)
Lee, Poshin; Chen, Da-Ren; Sanders, Terry (Technical Monitor)
2001-01-01
Considerable attention has been recently received on the impact of aircraft-produced aerosols upon the global climate. Sampling particles directly from jet engines has been performed by different research groups in the U.S. and Europe. However, a large variation has been observed among published data on the conversion efficiency and emission indexes of jet engines. The variation results surely from the differences in test engine types, engine operation conditions, and environmental conditions. The other factor that could result in the observed variation is the performance of sampling probes used. Unfortunately, it is often neglected in the jet engine community. Particle losses during the sampling, transport, and dilution processes are often not discussed/considered in literatures. To address this issue, we evaluated the performance of one sampling probe by challenging it with monodisperse particles. A significant performance difference was observed on the sampling probe evaluated under different temperature conditions. Thermophoretic effect, nonisokinetic sampling and turbulence loss contribute to the loss of particles in sampling probes. The results of this study show that particle loss can be dramatic if the sampling probe is not well designed. Further, the result allows ones to recover the actual size distributions emitted from jet engines.
Gao, S.; Fujii, R.; Chalmers, A.T.; Tanji, K.K.
2004-01-01
Elevated As concentrations in shallow groundwater in parts of the Tulare Basin, California, are a concern because of potential migration into deeper aquifers that could serve as a source of future drinking water. The objectives of this study were to evaluate adsorbed As and the potential contribution to groundwater using (i) isotopic dilution, (ii) successive extraction with an electrolyte solution resembling the pore-water chemical composition, and (iii) PO4 exchange for As. Sediment samples collected from 2 to 4 m below land surface in the Tulare Lake bed area contained a total As concentration of 24 mg As kg-1. Pore water extracted under hydraulic pressure contained a total As concentration of 590 ??g As L-1, which predominantly contained As as arsenate [As(V), 97%], a minor amount of arsenite [As(III), 3%], and non-detectable organic As. The isotopic dilution method [73As(V)] estimated that the concentration of adsorbed As(V) on the sediment was 5.7 mg As kg-1 at pH 8.5 and 6.7 mg As kg-1 at pH 7.5, respectively. Fourteen successive 24-h extractions with the artificial pore water released up to 57 to 61% of the adsorbed As(V) that was determined by isotopic dilution, indicating that only a portion of the adsorbed As could be released to groundwater. The phosphate-exchangeable As (0.1 M PO4, pH 8.5 or 7.5) was 63% of the isotopically exchangeable As(V). Thus, extraction of As by 0.1 M PO4 at ambient pHs is recommended as a method to determine the potential amount of As(V) on sediments that could be released to the solution phase. The overall results indicated that adsorbed As could be a significant source of As to groundwater. However, other factors that affect As transport such as the leaching rate need to be considered.
Synovial Fluid Response to Extensional Flow: Effects of Dilution and Intermolecular Interactions
Haward, Simon J.
2014-01-01
In this study, a microfluidic cross-slot device is used to examine the extensional flow response of diluted porcine synovial fluid (PSF) samples using flow-induced birefringence (FIB) measurements. The PSF sample is diluted to 10× 20× and 30× its original mass in a phosphate-buffered saline and its FIB response measured as a function of the strain rate at the stagnation point of the cross-slots. Equivalent experiments are also carried out using trypsin-treated PSF (t-PSF) in which the protein content is digested away using an enzyme. The results show that, at the synovial fluid concentrations tested, the protein content plays a negligible role in either the fluid's bulk shear or extensional flow behaviour. This helps support the validity of the analysis of synovial fluid HA content, either by microfluidic or by other techniques where the synovial fluid is first diluted, and suggests that the HA and protein content in synovial fluid must be higher than a certain minimum threshold concentration before HA-protein or protein-protein interactions become significant. However a systematic shift in the FIB response as the PSF and t-PSF samples are progressively diluted indicates that HA-HA interactions remain significant at the concentrations tested. These interactions influence FIB-derived macromolecular parameters such as the relaxation time and the molecular weight distribution and therefore must be minimized for the best validity of this method as an analytical technique, in which non-interaction between molecules is assumed. PMID:24651529
Synovial fluid response to extensional flow: effects of dilution and intermolecular interactions.
Haward, Simon J
2014-01-01
In this study, a microfluidic cross-slot device is used to examine the extensional flow response of diluted porcine synovial fluid (PSF) samples using flow-induced birefringence (FIB) measurements. The PSF sample is diluted to 10× 20× and 30× its original mass in a phosphate-buffered saline and its FIB response measured as a function of the strain rate at the stagnation point of the cross-slots. Equivalent experiments are also carried out using trypsin-treated PSF (t-PSF) in which the protein content is digested away using an enzyme. The results show that, at the synovial fluid concentrations tested, the protein content plays a negligible role in either the fluid's bulk shear or extensional flow behaviour. This helps support the validity of the analysis of synovial fluid HA content, either by microfluidic or by other techniques where the synovial fluid is first diluted, and suggests that the HA and protein content in synovial fluid must be higher than a certain minimum threshold concentration before HA-protein or protein-protein interactions become significant. However a systematic shift in the FIB response as the PSF and t-PSF samples are progressively diluted indicates that HA-HA interactions remain significant at the concentrations tested. These interactions influence FIB-derived macromolecular parameters such as the relaxation time and the molecular weight distribution and therefore must be minimized for the best validity of this method as an analytical technique, in which non-interaction between molecules is assumed.
Goodell, Christa K.; Zhang, Jianqiang; Strait, Erin; Harmon, Karen; Patnayak, Devi; Otterson, Tracy; Culhane, Marie; Christopher-Hennings, Jane; Clement, Travis; Leslie-Steen, Pamela; Hesse, Richard; Anderson, Joe; Skarbek, Kevin; Vincent, Amy; Kitikoon, Pravina; Swenson, Sabrina; Jenkins-Moore, Melinda; McGill, Jodi; Rauh, Rolf; Nelson, William; O’Connell, Catherine; Shah, Rohan; Wang, Chong; Main, Rodger; Zimmerman, Jeffrey J.
2016-01-01
The probability of detecting influenza A virus (IAV) in oral fluid (OF) specimens was calculated for each of 13 assays based on real-time reverse-transcription polymerase chain reaction (rRT-PCR) and 7 assays based on virus isolation (VI). The OF specimens were inoculated with H1N1 or H3N2 IAV and serially diluted 10-fold (10−1 to 10−8). Eight participating laboratories received 180 randomized OF samples (10 replicates × 8 dilutions × 2 IAV subtypes plus 20 IAV-negative samples) and performed the rRT-PCR and VI procedure(s) of their choice. Analysis of the results with a mixed-effect logistic-regression model identified dilution and assay as variables significant (P < 0.0001) for IAV detection in OF by rRT-PCR or VI. Virus subtype was not significant for IAV detection by either rRT-PCR (P = 0.457) or VI (P = 0.101). For rRT-PCR the cycle threshold (Ct) values increased consistently with dilution but varied widely. Therefore, it was not possible to predict VI success on the basis of Ct values. The success of VI was inversely related to the dilution of the sample; the assay was generally unsuccessful at lower virus concentrations. Successful swine health monitoring and disease surveillance require assays with consistent performance, but significant differences in reproducibility were observed among the assays evaluated. PMID:26733728
Alcorn, S.W.; Pascho, R.J.
2000-01-01
An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibaclerium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.
Lawler, Jacquelin Boggs; Hassel, Diana M; Magnuson, Roberta J; Hill, Ashley E; McCue, Patrick M; Traub-Dargatz, Josie L
2008-02-01
To determine the adsorptive capability of di-tri-octahedral smectite (DTOS) on Clostridium perfringens alpha, beta, and beta-2 exotoxins and equine colostral antibodies. 3 C perfringens exotoxins and 9 colostral samples. Alpha, beta, and beta-2 exotoxins were individually co-incubated with serial dilutions of DTOS or bismuth subsalicylate, and the amount of toxin remaining after incubation was determined via toxin-specific ELISAs. Colostral samples from healthy mares were individually co-incubated with serial dilutions of DTOS, and colostral IgG concentrations were determined via single radial immunodiffusion assay. Di-tri-octahedral smectite decreased the amount of each C perfringens exotoxin in co-incubated samples in a dose-dependent manner and was more effective than bismuth subsalicylate at reducing exotoxins in vitro. Decreases in the concentration of IgG were detected in samples of colostrum that were combined with DTOS at 1:4 through 1:16 dilutions, whereas no significant decrease was evident with DTOS at the 1:32 dilution. Di-tri-octahedral smectite effectively adsorbed C perfringens exotoxins in vitro and had a dose-dependent effect on the availability of equine colostral antibodies. Results suggested that DTOS may be an appropriate adjunctive treatment in the management of neonatal clostridiosis in horses. In vivo studies are necessary to fully assess the clinical efficacy of DTOS treatment.
López-Urueña, E; Alvarez, M; Gomes-Alves, S; Anel-López, L; Martínez-Rodríguez, C; Manrique, P; Borragan, S; Anel, L; de Paz, P
2015-10-15
Brown bear ejaculates are usually collected in field conditions and may need to be shipped to a laboratory for the application of reproductive biotechnologies before cryopreservation. The aim of this study was to extend the prefreezing step to 48 hours (1 hour vs. long-term storage [LS] to 24 and 48 hours) to enable the sample to be transported. The effects of storage temperature (experiment 1), glycerol concentration (experiment 2), and dilution rate (experiment 3) on sperm were evaluated. Electroejaculates from brown bears were stored under different experimental conditions and cryopreserved. The sperm motility and viability, apoptotic status, and acrosomal status of sperm were assessed before freezing (prefreezing), after thawing, and after 2-hour incubation at 37 °C (thermal stress test). In all experiments, one control sample was frozen using a standard protocol (control). In experiment 1, three temperatures during LS with 6% glycerol were tested: 5 °C (T5), 15 °C (T15), and room temperature (RT). The LS-T5 sample yielded the highest postthawing results for viability (42.4%), progressive motility (15.6%), and intact acrosome (83.1%) after 24 hours in comparison with the other temperatures (P < 0.05); for 48 hours, the LS-T5 sample reached higher total and progressive motility (25.9% and 9%, respectively) and nonapoptotic values (36.5%). Recovery rates revealed susceptibility to freezing at LS-15 or LS-RT samples at 24 hours (viability) or 48 hours (viability and motility). In experiment 2, samples were stored at 5 °C up to 48 hours and three glycerol concentrations were evaluated: 0% (0Gly), 3% (3Gly), and 6% (6Gly). Postthawing viability and motility increased progressively with the percentage of glycerol for 24 hours at 5 °C; 6% glycerol during 48-hour storage had beneficial effects on sperm cryopreservation. Besides, 6% glycerol had a clearly superior freezability for viability (42.7% and 40.8% for 24 hours and 48 hours, respectively) and motility (24 hours: total, 44.1%; progressive, 17.1%; 48 hours: total, 38.4%; progressive, 16%). In experiment 3, samples were stored up to 48 hours at 5 °C with 6% of glycerol and two dilution methods were evaluated: dilution 1:1 (average: 1782 × 10(6) sperm/mL; low) or final dilution (100 × 10(6) sperm/mL; high). Both dilution rates showed similar postthawing and postincubation results within 24 hours of long-term storage. After 48 hours, high dilution supported better postthawing quality. Both dilutions showed similar resistance to cryopreservation, except after 48 hours, when the high dilution reached a higher percent recovery rate of viability (38.8% vs. 21.6%, P < 0.05). In conclusion, our results suggested that the best conditions for long-term prefreezing storage (up to 48 hours) of brown bear electroejaculates are at 5 °C, at a concentration of 100 × 10(6) sperm/mL, and with 6% glycerol. Copyright © 2015 Elsevier Inc. All rights reserved.
Wang, Hexing; Wang, Na; Wang, Bin; Zhao, Qi; Fang, Hong; Fu, Chaowei; Tang, Chuanxi; Jiang, Feng; Zhou, Ying; Chen, Yue; Jiang, Qingwu
2016-03-01
A variety of antibiotics have been found in aquatic environments, but antibiotics in drinking water and their contribution to antibiotic exposure in human are not well-explored. For this, representative drinking water samples and 530 urine samples from schoolchildren were selected in Shanghai, and 21 common antibiotics (five macrolides, two β-lactams, three tetracyclines, four fluoquinolones, four sulfonamides, and three phenicols) were measured in water samples and urines by isotope dilution two-dimensional ultraperformance liquid chromatography coupled with high-resolution quadrupole time-of-flight mass spectrometry. Drinking water included 46 terminal tap water samples from different spots in the distribution system of the city, 45 bottled water samples from 14 common brands, and eight barreled water samples of different brands. Of 21 antibiotics, only florfenicol and thiamphenicol were found in tap water, with the median concentrations of 0.0089 ng/mL and 0.0064 ng/mL, respectively; only florfenicol was found in three bottled water samples from a same brand, with the concentrations ranging from 0.00060 to 0.0010 ng/mL; no antibiotics were found in barreled water. In contrast, besides florfenicol and thiamphenicol, an additional 17 antibiotics were detected in urine samples, and the total daily exposure doses and detection frequencies of florfenicol and thiamphenicol based on urine samples were significantly and substantially higher than their predicted daily exposure doses and detection frequencies from drinking water by Monte Carlo Simulation. These data indicated that drinking water was contaminated by some antibiotics in Shanghai, but played a limited role in antibiotic exposure of children.
Seifi-Jamadi, Afshin; Kohram, Hamid; Zareh-Shahne, Ahmad; Dehghanizadeh, Parvaneh; Ahmad, Ejaz
2016-07-01
The present study aimed to determine the effect of different concentrations of butylated hydroxyanisole (BHA) and butylated hydroxytoluene (BHT) on post-thaw stallion sperm quality. The ejaculates collected from four healthy mature Turkmen stallions were pooled and divided into eight aliquots. The samples were diluted with extenders containing different concentrations (0.5, 1 or 2mM/mL) of BHA or BHT. The positive control (PC) samples were diluted with extender containing 0.5% ethanol (v/v) whereas; the negative control (NC) samples were diluted with basic extender only. Semen samples were frozen according to a standard protocol. After thawing of samples, sperm motility, viability, membrane integrity, total abnormality and lipid peroxidation were assessed. The greatest (P<0.05) values for total sperm motility, viability and plasma membrane functionality and least values for malonedialdehyde (MDA) concentration were observed in samples supplemented either with 1mM BHT or 2mM BHA. However, the progressive motility was greater (P<0.05) only in samples treated with 2mM BHA. In conclusion, the use of 1mM BHT or 2mM BHA in extender improves the freezing capacity of stallion sperm by reducing oxidative stress during freeze-thaw process. Copyright © 2016 Elsevier B.V. All rights reserved.
White blood cell counting system
NASA Technical Reports Server (NTRS)
1972-01-01
The design, fabrication, and tests of a prototype white blood cell counting system for use in the Skylab IMSS are presented. The counting system consists of a sample collection subsystem, sample dilution and fluid containment subsystem, and a cell counter. Preliminary test results show the sample collection and the dilution subsystems are functional and fulfill design goals. Results for the fluid containment subsystem show the handling bags cause counting errors due to: (1) adsorption of cells to the walls of the container, and (2) inadequate cleaning of the plastic bag material before fabrication. It was recommended that another bag material be selected.
Kish, G.R.; Stringer, C.E.; Stewart, M.T.; Rains, M.C.; Torres, A.E.
2010-01-01
Geochemical mass-balance (GMB) and conductivity mass-balance (CMB) methods for hydrograph separation were used to determine the contribution of base flow to total stormflow at two sites in the upper Hillsborough River watershed in west-central Florida from 2003-2005 and at one site in 2009. The chemical and isotopic composition of streamflow and precipitation was measured during selected local and frontal low- and high-intensity storm events and compared to the geochemical and isotopic composition of groundwater. Input for the GMB method included cation, anion, and stable isotope concentrations of surface water and groundwater, whereas input for the CMB method included continuous or point-sample measurement of specific conductance. The surface water is a calcium-bicarbonate type water, which closely resembles groundwater geochemically, indicating that much of the surface water in the upper Hillsborough River basin is derived from local groundwater discharge. This discharge into the Hillsborough River at State Road 39 and at Hillsborough River State Park becomes diluted by precipitation and runoff during the wet season, but retains the calcium-bicarbonate characteristics of Upper Floridan aquifer water. Field conditions limited the application of the GMB method to low-intensity storms but the CMB method was applied to both low-intensity and high-intensity storms. The average contribution of base flow to total discharge for all storms ranged from 31 to 100 percent, whereas the contribution of base flow to total discharge during peak discharge periods ranged from less than 10 percent to 100 percent. Although calcium, magnesium, and silica were consistent markers of Upper Floridan aquifer chemistry, their use in calculating base flow by the GMB method was limited because the frequency of point data collected in this study was not sufficient to capture the complete hydrograph from pre-event base-flow to post-event base-flow concentrations. In this study, pre-event water represented somewhat diluted groundwater. Streamflow conductivity integrates the concentrations of the major ions, and the logistics of acquiring specific conductance at frequent time intervals are less complicated than data collection, sample processing, shipment, and analysis of water samples in a laboratory. The acquisition of continuous specific conductance data reduces uncertainty associated with less-frequently collected geochemical point data.
NASA Technical Reports Server (NTRS)
Meneghelli, Barry; Parrish, Clyde; Barile, Ron; Lueck, Dale E.
1995-01-01
A Hydrazine Vapor Area Monitor (HVAM) system is currently being field tested as a detector for the presence of hydrazine in ambient air. The MDA/Polymetron Hydrazine Analyzer has been incorporated within the HVAM system as the core detector. This analyzer is a three-electrode liquid analyzer typically used in boiler feed water applications. The HVAM system incorporates a dual-phase sample collection/transport method which simultaneously pulls ambient air samples containing hydrazine and a very dilute sulfuric acid solution (0.0001 M) down a length of 1/4 inch outside diameter (OD) tubing from a remote site to the analyzer. The hydrazine-laden dilute acid stream is separated from the air and the pH is adjusted by addition of a dilute caustic solution to a pH greater than 10.2 prior to analysis. Both the dilute acid and caustic used by the HVAM are continuously generated during system operation on an "as needed" basis by mixing a metered amount of concentrated acid/base with dilution water. All of the waste water generated by the analyzer is purified for reuse by Barnstead ion-exchange cartridges so that the entire system minimizes the generation of waste materials. The pumping of all liquid streams and mixing of the caustic solution and dilution water with the incoming sample are done by a single pump motor fitted with the appropriate mix of peristaltic pump heads. The signal to noise (S/N) ratio of the analyzer has been enhanced by adding a stirrer in the MDA liquid cell to provide mixing normally generated by the high liquid flow rate designed by the manufacturer. An onboard microprocessor continuously monitors liquid levels, sample vacuum, and liquid leak sensors, as well as handles communications and other system functions (such as shut down should system malfunctions or errors occur). The overall system response of the HVAM can be automatically checked at regular intervals by measuring the analyzer response to a metered amount of calibration standard injected into the dilute acid stream. The HVAM system provides two measurement ranges (threshold limit value (TLV): 10 to 1000 parts per billion (ppb)/LEAK: 100 ppb to 10 parts per million (ppm)). The LEAK range is created by dilution of the sulfuric acid/hydrazine liquid sample with pure water. This dual range capability permits the analyzer to quantify ambient air samples whose hydrazine concentrations range from 10 ppb to as high as 10 ppm. The laboratory and field prototypes have demonstrated total system response times on the order of 10 to 12 minutes for samples ranging from 10 to 900 ppb in the lLV mode and is greater than 2 minutes for samples ranging from 100 to 1300 ppb in the LEAK mode. Service intervals of over 3 months have been demonstrated for continuous 24 hour/day, 7 day/week usage. The HVAM is made up of a purged cabinet that contains power supplies, RS422 signal transmission capabilities, a UPS, an on-site warning system, and a Line Replaceable Unit (LRU). The LRU includes all of the liquid flow system, the analyzer, the control/data system microprocessor and assorted flow and liquid-level sensors. The LRU is mounted on a track slide system so it can be serviced inplace or totally removed and quickly exchanged with another calibrated unit, thus minimizing analyzer downtime. Once an LRU is removed from an analyzer enclosure, it can be brought to a laboratory facility for complete calibration and periodic maintenance.
Wollanke, B; Gerhards, H; Brem, S; Kopp, H; Meyer, P
1998-04-01
Between February 1993 and July 1997, 150 horses suffering from recurrent uveitis were subjected to parsplana vitrectomy. In these horses, antibody titers to Leptospira serovars were determined in serum samples and in samples from diluted vitreous collected during vitrectomy. Although the vitreous samples were diluted with 250 ml of balanced salt solution, in 86 of the 150 vitreous samples (= 57%) the antibody titers were higher than in the serum samples. Additionally, serum samples from 77 horses suffering from ERU, but which were not subjected to vitrectomy, and serum samples from 97 horses with clinically normal eyes were analyzed for antibodies to Leptospira serovars. Among the 227 horses with ERU (150 treated surgically, 77 treated conservatively) 50 horses (50 of 227 = 22%) had serum antibody titers to Leptospira serovars of > or = 1:800. Among the 97 horses with clinically normal eyes, 24 horses (24 of 97 = 25%) had serum antibody titers to Leptospira serovars of > or = 1:800. In undiluted vitreous samples from 20 horses with clinically normal eyes, no antibody titers to Leptospira serovars could be detected. Among the 150 horses with ERU, 90 animals (90 of 150 = 60%) had antibody titers of > or = 1:100 in the diluted vitreous samples, the difference being highly significant (p < 0.001). The findings are discussed in relation to the etiology of recurrent uveitis in horses.
Fernández-Fernández, Mario; Rodríguez-González, Pablo; Añón Álvarez, M Elena; Rodríguez, Felix; Menéndez, Francisco V Álvarez; García Alonso, J Ignacio
2015-04-07
This work describes the first multiple spiking isotope dilution procedure for organic compounds using (13)C labeling. A double-spiking isotope dilution method capable of correcting and quantifying the creatine-creatinine interconversion occurring during the analytical determination of both compounds in human serum is presented. The determination of serum creatinine may be affected by the interconversion between creatine and creatinine during sample preparation or by inefficient chemical separation of those compounds by solid phase extraction (SPE). The methodology is based on the use differently labeled (13)C analogues ((13)C1-creatinine and (13)C2-creatine), the measurement of the isotopic distribution of creatine and creatinine by liquid chromatography-tandem mass spectrometry (LC-MS/MS) and the application of multiple linear regression. Five different lyophilized serum-based controls and two certified human serum reference materials (ERM-DA252a and ERM-DA253a) were analyzed to evaluate the accuracy and precision of the proposed double-spike LC-MS/MS method. The methodology was applied to study the creatine-creatinine interconversion during LC-MS/MS and gas chromatography-mass spectrometry (GC-MS) analyses and the separation efficiency of the SPE step required in the traditional gas chromatography-isotope dilution mass spectrometry (GC-IDMS) reference methods employed for the determination of serum creatinine. The analysis of real serum samples by GC-MS showed that creatine-creatinine separation by SPE can be a nonquantitative step that may induce creatinine overestimations up to 28% in samples containing high amounts of creatine. Also, a detectable conversion of creatine into creatinine was observed during sample preparation for LC-MS/MS. The developed double-spike LC-MS/MS improves the current state of the art for the determination of creatinine in human serum by isotope dilution mass spectrometry (IDMS), because corrections are made for all the possible errors derived from the sample preparation step.
Declining ecosystem health and the dilution effect.
Khalil, Hussein; Ecke, Frauke; Evander, Magnus; Magnusson, Magnus; Hörnfeldt, Birger
2016-08-08
The "dilution effect" implies that where species vary in susceptibility to infection by a pathogen, higher diversity often leads to lower infection prevalence in hosts. For directly transmitted pathogens, non-host species may "dilute" infection directly (1) and indirectly (2). Competitors and predators may (1) alter host behavior to reduce pathogen transmission or (2) reduce host density. In a well-studied system, we tested the dilution of the zoonotic Puumala hantavirus (PUUV) in bank voles (Myodes glareolus) by two competitors and a predator. Our study was based on long-term PUUV infection data (2003-2013) in northern Sweden. The field vole (Microtus agrestis) and the common shrew (Sorex araneus) are bank vole competitors and Tengmalm's owl (Aegolius funereus) is a main predator of bank voles. Infection probability in bank voles decreased when common shrew density increased, suggesting that common shrews reduced PUUV transmission. Field voles suppressed bank vole density in meadows and clear-cuts and indirectly diluted PUUV infection. Further, Tengmalm's owl decline in 1980-2013 may have contributed to higher PUUV infection rates in bank voles in 2003-2013 compared to 1979-1986. Our study provides further evidence for dilution effect and suggests that owls may have an important role in reducing disease risk.
Quantifying the dilution effect for models in ecological epidemiology.
Roberts, M G; Heesterbeek, J A P
2018-03-01
The dilution effect , where an increase in biodiversity results in a reduction in the prevalence of an infectious disease, has been the subject of speculation and controversy. Conversely, an amplification effect occurs when increased biodiversity is related to an increase in prevalence. We explore the conditions under which these effects arise, using multi species compartmental models that integrate ecological and epidemiological interactions. We introduce three potential metrics for quantifying dilution and amplification, one based on infection prevalence in a focal host species, one based on the size of the infected subpopulation of that species and one based on the basic reproduction number. We introduce our approach in the simplest epidemiological setting with two species, and show that the existence and strength of a dilution effect is influenced strongly by the choices made to describe the system and the metric used to gauge the effect. We show that our method can be generalized to any number of species and to more complicated ecological and epidemiological dynamics. Our method allows a rigorous analysis of ecological systems where dilution effects have been postulated, and contributes to future progress in understanding the phenomenon of dilution in the context of infectious disease dynamics and infection risk. © 2018 The Author(s).
Guideline on Isotope Dilution Mass Spectrometry
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaffney, Amy
Isotope dilution mass spectrometry is used to determine the concentration of an element of interest in a bulk sample. It is a destructive analysis technique that is applicable to a wide range of analytes and bulk sample types. With this method, a known amount of a rare isotope, or ‘spike’, of the element of interest is added to a known amount of sample. The element of interest is chemically purified from the bulk sample, the isotope ratio of the spiked sample is measured by mass spectrometry, and the concentration of the element of interest is calculated from this result. Thismore » method is widely used, although a mass spectrometer required for this analysis may be fairly expensive.« less
Lopez-Urueña, E; Anel-López, L; Borragan, S; Ortega Ferrusola, C; Manrique, P; de Paz, P; Anel, L; Alvarez, M
2016-10-01
Sedimentation of spermatozoa occurs during long-term liquid storage and this may produce deleterious changes. Our aim was to apply gelatine supplementation during long-term pre-freezing storage of bear sperm, applying final dilution and 6% glycerol at room temperature and cool in straws. We tested four models of sperm storage using a 1:1 dilution in TTF-ULE-Bear extender (TesT-fructose-egg yolk-glycerol 6%): (i) second 1:1 dilution at room temperature (RT), cooling at 5°C in a tube and final dilution (100 × 10(6) sperm ml(-1) ) (Standard); (ii) final dilution at RT and cooling in a tube (FD-Tube); (iii) final dilution at RT and cooling in 0.25 ml plastic straw (FD-Straw); and (iv) final dilution at RT in extender supplemented with 1.5% gelatine (Gelatine) and cooling in a 0.25 ml plastic straw. A Standard sample was stored at 5°C for 1 hr (Control); the rest of the samples (Standard, FD-Tube, FD-Straw, Gelatine) were stored for 24 or 48 hrs before freezing (100 × 10(6) sperm ml(-1) , glycerol 6%). The quality of the samples was assessed for motility by CASA, and viability (SYBR-14/propidium iodide-PI-; VIAB), acrosomal status (PNA-FITC/PI; iACR) and apoptotic status (YO-PRO-1/PI; YOPRO-) by flow cytometry. At pre-freezing, after 48 hr, Gelatine showed significantly higher viability (for VIAB and YOPRO-) and progressiveness (PM, LIN and STR). At 48 hr, Gelatine showed similar YOPRO-, iACR, LIN, STR and ALH respect to Control. At both 24 and 48 h post-thawing, Gelatine sample had similar scores for YOPRO-, iACR, LIN, STR, WOB and VIAB (only 24 hr) when compared with Control, and lower for TM, PM, rapidPM, VAP and ALH. No differences were found among others experimental groups with respect to Control. In conclusion, gelatine could be a suitable alternative to preserve the viability and progressive motility of brown bear ejaculates during long-term pre-freezing storage at 5°C. © 2016 Blackwell Verlag GmbH.
Chao Zhang; Xinshu Zhuang; Zhao Jiang Wang; Fred Matt; Franz St. John; J.Y. Zhu
2013-01-01
Three pairs of solid substrates from dilute acid pretreatment of two poplar wood samples were enzymatically hydrolyzed by cellulase preparations supplemented with xylanase. Supplementation of xylanase improved cellulose saccharification perhaps due to improved cellulose accessibility by xylan hydrolysis. Total xylan removal directly affected enzymatic cellulose...
L-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array
NASA Astrophysics Data System (ADS)
Titus, Charles J.; Baker, Michael L.; Lee, Sang Jun; Cho, Hsiao-Mei; Doriese, William B.; Fowler, Joseph W.; Gaffney, Kelly; Gard, Johnathon D.; Hilton, Gene C.; Kenney, Chris; Knight, Jason; Li, Dale; Marks, Ronald; Minitti, Michael P.; Morgan, Kelsey M.; O'Neil, Galen C.; Reintsema, Carl D.; Schmidt, Daniel R.; Sokaras, Dimosthenis; Swetz, Daniel S.; Ullom, Joel N.; Weng, Tsu-Chien; Williams, Christopher; Young, Betty A.; Irwin, Kent D.; Solomon, Edward I.; Nordlund, Dennis
2017-12-01
We present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100-2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique ability to characterize frozen solutions of radiation- and temperature-sensitive samples.
Nitsos, Christos; Matsakas, Leonidas; Triantafyllidis, Kostas; Rova, Ulrika; Christakopoulos, Paul
2015-01-01
Hydrothermal, dilute acid, and steam explosion pretreatment methods, were evaluated for their efficiency to improve the methane production yield of three Mediterranean agricultural lignocellulosic residues such as olive tree pruning, grapevine pruning, and almond shells. Hydrothermal and dilute acid pretreatments provided low to moderate increase in the digestibility of the biomass samples, whereas steam explosion enabled the highest methane yields to be achieved for almond shells at 232.2 ± 13.0 mL CH4/gVS and olive pruning at 315.4 ± 0.0 mL CH4/gVS. Introduction of an enzymatic prehydrolysis step moderately improved methane yields for hydrothermal and dilute acid pretreated samples but not for the steam exploded ones.
Nitsos, Christos; Triantafyllidis, Kostas
2015-01-01
Hydrothermal, dilute acid, and steam explosion pretreatment methods, were evaluated for their efficiency to improve the methane production yield of three Mediterranean agricultural lignocellulosic residues such as olive tree pruning, grapevine pruning, and almond shells. Hydrothermal and dilute acid pretreatments provided low to moderate increase in the digestibility of the biomass samples, whereas steam explosion enabled the highest methane yields to be achieved for almond shells at 232.2 ± 13.0 mL CH4/gVS and olive pruning at 315.4 ± 0.0 mL CH4/gVS. Introduction of an enzymatic prehydrolysis step moderately improved methane yields for hydrothermal and dilute acid pretreated samples but not for the steam exploded ones. PMID:26609521
NASA Astrophysics Data System (ADS)
Lu, Guoping; Sonnenthal, Eric L.; Bodvarsson, Gudmundur S.
2008-12-01
The standard dual-component and two-member linear mixing model is often used to quantify water mixing of different sources. However, it is no longer applicable whenever actual mixture concentrations are not exactly known because of dilution. For example, low-water-content (low-porosity) rock samples are leached for pore-water chemical compositions, which therefore are diluted in the leachates. A multicomponent, two-member mixing model of dilution has been developed to quantify mixing of water sources and multiple chemical components experiencing dilution in leaching. This extended mixing model was used to quantify fracture-matrix interaction in construction-water migration tests along the Exploratory Studies Facility (ESF) tunnel at Yucca Mountain, Nevada, USA. The model effectively recovers the spatial distribution of water and chemical compositions released from the construction water, and provides invaluable data on the matrix fracture interaction. The methodology and formulations described here are applicable to many sorts of mixing-dilution problems, including dilution in petroleum reservoirs, hydrospheres, chemical constituents in rocks and minerals, monitoring of drilling fluids, and leaching, as well as to environmental science studies.
Abe, Shigeaki; Hyono, Atsushi; Kawai, Koji; Yonezawa, Tetsu
2014-03-01
In this study, we investigated conductivity preparation for scanning electron microscope (SEM) observation that used novel asymmetrical choline-type room temperature ionic liquids (RTIL). By immersion in only an RTIL solution, clear SEM images of several types of biological samples were successfully observed. In addition, we could visualize protozoans using RTILs without any dilution. These results suggested that the asymmetrical choline-type RTILs used in this study are suitable for visualizing of biological samples by SEM. Treatment without the need for dilution can obviate the need for adjusting the RTIL concentration and provide for a rapid and easy conductivity treatment for insulating samples.
Goldhaber, Martin B.; Mills, Christopher T.; Mushet, David M.; McCleskey, R. Blaine; Rover, Jennifer
2016-01-01
One hundred sixty-seven Prairie Pothole lakes, ponds and wetlands (largely lakes) previously analyzed chemically during the late 1960’s and early to mid-1970’s were resampled and reanalyzed in 2011–2012. The two sampling periods differed climatically. The earlier sampling took place during normal to slightly dry conditions, whereas the latter occurred during and immediately following exceptionally wet conditions. As reported previously in Mushet et al. (2015), the dominant effect was expansion of the area of these lakes and dilution of their major ions. However, within that context, there were significant differences in the evolutionary pathways of major ions. To establish these pathways, we employed the inverse modeling computer code NetpathXL. This code takes the initial and final lake composition and, using mass balance constrained by the composition of diluting waters, and input and output of phases, calculates plausible geochemical evolution pathways. Despite the fact that in most cases major ions decreased, a subset of the lakes had an increase in SO42−. This distinction is significant because SO42− is the dominant anion in a majority of Prairie Pothole Region wetlands and lakes. For lakes with decreasing SO42−, the proportion of original lake water required for mass balance was subordinate to rainwater and/or overland flow. In contrast, lakes with increasing SO42− between the two sampling episodes tended to be dominated by original lake water. This suite of lakes tended to be smaller and have lower initial SO42−concentrations such that inputs of sulfur from dissolution of the minerals gypsum or pyrite had a significant impact on the final sulfur concentration given the lower dilution factors. Thus, our study provides context for how Prairie Pothole Region water bodies evolve geochemically as climate changes. Because wetland geochemistry in turn controls the ecology of these water bodies, this research contributes to the prediction of the impact of climate change on this important complex of ecosystems.
Rheology and TIC/TOC results of ORNL tank samples
DOE Office of Scientific and Technical Information (OSTI.GOV)
Pareizs, J. M.; Hansen, E. K.
2013-04-26
The Savannah River National Laboratory (SRNL)) was requested by Oak Ridge National Laboratory (ORNL) to perform total inorganic carbon (TIC), total organic carbon (TOC), and rheological measurements for several Oak Ridge tank samples. As received slurry samples were diluted and submitted to SRNL-Analytical for TIC and TOC analyses. Settled solids yield stress (also known as settled shear strength) of the as received settled sludge samples were determined using the vane method and these measurements were obtained 24 hours after the samples were allowed to settled undisturbed. Rheological or flow properties (Bingham Plastic viscosity and Bingham Plastic yield stress) were determinedmore » from flow curves of the homogenized or well mixed samples. Other targeted total suspended solids (TSS) concentrations samples were also analyzed for flow properties and these samples were obtained by diluting the as-received sample with de-ionized (DI) water.« less
Fast and accurate calculation of dilute quantum gas using Uehling–Uhlenbeck model equation
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yano, Ryosuke, E-mail: ryosuke.yano@tokiorisk.co.jp
The Uehling–Uhlenbeck (U–U) model equation is studied for the fast and accurate calculation of a dilute quantum gas. In particular, the direct simulation Monte Carlo (DSMC) method is used to solve the U–U model equation. DSMC analysis based on the U–U model equation is expected to enable the thermalization to be accurately obtained using a small number of sample particles and the dilute quantum gas dynamics to be calculated in a practical time. Finally, the applicability of DSMC analysis based on the U–U model equation to the fast and accurate calculation of a dilute quantum gas is confirmed by calculatingmore » the viscosity coefficient of a Bose gas on the basis of the Green–Kubo expression and the shock layer of a dilute Bose gas around a cylinder.« less
Hossain, Mirza Akram; Friciu, Mihaela; Aubin, Sebastien; Leclair, Grégoire
2014-04-15
The stability of penicillin G sodium solutions stored in polyvinyl chloride (PVC) bags or elastomeric pump containers was studied. Test samples were prepared by diluting powdered penicillin G sodium (10 million units/10-mL vial) to solutions of 2,500 or 50,000 units/mL with 0.9% sodium chloride injection or 5% dextrose injection. The preparations were transferred to 250-mL PVC bags and elastomeric pump containers. All samples were prepared in triplicate and stored at 5°C. Chemical stability was measured by a stability-indicating high-performance liquid chromatographic (HPLC) assay and by pH evaluation. Particulate matter was evaluated according to compendial standards using a light-obscuration particle count test. Preparations were visually examined throughout the study. After 21 days of storage, all test samples remained chemically stable, with an HPLC assay recovery value of more than 90% of the initial value. After 28 days, all samples prepared with either diluent and stored in PVC bags, as well as the samples diluted to 2,500 units/mL with sodium chloride injection and stored in elastomeric pump containers, did not meet the recovery acceptance limit. For all test samples, the mean pH consistently decreased during storage, from about 6.4 to about 5.5. Particle counts remained acceptable throughout the study, and no change in appearance was observed. Penicillin G for injection (2,500 and 50,000 units/mL) diluted in 0.9% sodium chloride injection or 5% dextrose injection and stored at 5°C in PVC containers or elastomeric pump containers was physically and chemically stable for a period of at least 21 days.
Goh, Sherry Meow Peng; Swaminathan, Muthukaruppan; Lai, Julian U-Ming; Anwar, Azlinda; Chan, Soh Ha; Cheong, Ian
2017-01-01
High Epstein Barr Virus (EBV) titers detected by the indirect Immunofluorescence Assay (IFA) are a reliable predictor of Nasopharyngeal Carcinoma (NPC). Despite being the gold standard for serological detection of NPC, the IFA is limited by scaling bottlenecks. Specifically, 5 serial dilutions of each patient sample must be prepared and visually matched by an evaluator to one of 5 discrete titers. Here, we describe a simple method for inferring continuous EBV titers from IFA images acquired from NPC-positive patient sera using only a single sample dilution. In the first part of our study, 2 blinded evaluators used a set of reference titer standards to perform independent re-evaluations of historical samples with known titers. Besides exhibiting high inter-evaluator agreement, both evaluators were also in high concordance with historical titers, thus validating the accuracy of the reference titer standards. In the second part of the study, the reference titer standards were IFA-processed and assigned an 'EBV Score' using image analysis. A log-linear relationship between titers and EBV Score was observed. This relationship was preserved even when images were acquired and analyzed 3days post-IFA. We conclude that image analysis of IFA-processed samples can be used to infer a continuous EBV titer with just a single dilution of NPC-positive patient sera. This work opens new possibilities for improving the accuracy and scalability of IFA in the context of clinical screening. Copyright © 2016. Published by Elsevier B.V.
Zhang, Hongyan; Wang, Lei; Zhang, Yan; Fang, Guozhen; Zheng, Wenjie; Wang, Shuo
2007-03-21
Direct competitive enzyme-linked immunosorbent assays (ELISA) were developed to detect a broad range of sulfonamides in various matrices. Screening for this class of antibiotics in pig muscle, chicken muscle, fish, and egg extracts was accomplished by simple, rapid extraction methods carried out with only phosphate-buffered saline (PBS) buffer. Twenty milliliters of extract solution was added to 4 g of sample to extract the sulfonamide residues, and sample extracts diluted with assay buffer were directly analyzed by ELISA; matrix effects could be avoided with 1:5 dilution of pig muscle, chicken muscle, and egg extracts with PBS and 1:5 dilution of fish extract with 1% bovine serum albumin (BSA)-PBS. For liver sample, the extraction method was a little more complicated; 2 g of sample was added to 20 mL of ethanol, mixed, and then centrifuged. The solvent of 10 mL of the upper liquid was removed, and the residues were dissolved in 10 mL of PBS and then filtered; the filtrate was diluted two-fold with 0.5% BSA-PBS for ELISA. These common methods were able to detect seven sulfonamide residues such as sulfisozole, sulfathiazole, sufameter, sulfamethoxypyridazine, sulfapyridine, sulfamethizole, and sulfachlorpyridazine in pig muscle, liver, chicken muscle, egg, and fish. The assay's detection limits for these compounds were less than 100 microg kg-1. Various extraction methods were tested, and the average recovery (n=3) of 100 microg kg-1 for the matrices was found to range from 77.3 to 123.7%.
Ahumada, Luis Armando Carvajal; González, Marco Xavier Rivera; Sandoval, Oscar Leonardo Herrera; Olmedo, José Javier Serrano
2016-01-01
The main objective of this article is to demonstrate through experimental means the capacity of the quartz crystal resonator (QCR) to characterize biological samples of aqueous dilutions of hyaluronic acid according to their viscosity and how this capacity may be useful in the potential diagnosis of arthritic diseases. The synovial fluid is viscous due to the presence of hyaluronic acid, synthesized by synovial lining cells (type B), and secreted into the synovial fluid thus making the fluid viscous. In consequence, aqueous dilutions of hyaluronic acid may be used as samples to emulate the synovial fluid. Due to the viscoelastic and pseudo-plastic behavior of hyaluronic acid, it is necessary to use the Rouse model in order to obtain viscosity values comparable with viscometer measures. A Fungilab viscometer (rheometer) was used to obtain reference measures of the viscosity in each sample in order to compare them with the QCR prototype measures. PMID:27879675
Chan, George C. Y. [Bloomington, IN; Hieftje, Gary M [Bloomington, IN
2010-08-03
A method for detecting and correcting inaccurate results in inductively coupled plasma-atomic emission spectrometry (ICP-AES). ICP-AES analysis is performed across a plurality of selected locations in the plasma on an unknown sample, collecting the light intensity at one or more selected wavelengths of one or more sought-for analytes, creating a first dataset. The first dataset is then calibrated with a calibration dataset creating a calibrated first dataset curve. If the calibrated first dataset curve has a variability along the location within the plasma for a selected wavelength, errors are present. Plasma-related errors are then corrected by diluting the unknown sample and performing the same ICP-AES analysis on the diluted unknown sample creating a calibrated second dataset curve (accounting for the dilution) for the one or more sought-for analytes. The cross-over point of the calibrated dataset curves yields the corrected value (free from plasma related errors) for each sought-for analyte.
40 CFR 1065.150 - Continuous sampling.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 40 Protection of Environment 32 2010-07-01 2010-07-01 false Continuous sampling. 1065.150 Section... ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.150 Continuous sampling. You may use continuous sampling techniques for measurements that involve raw or dilute sampling. Make sure continuous sampling...
40 CFR 1065.150 - Continuous sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 40 Protection of Environment 33 2011-07-01 2011-07-01 false Continuous sampling. 1065.150 Section... ENGINE-TESTING PROCEDURES Equipment Specifications § 1065.150 Continuous sampling. You may use continuous sampling techniques for measurements that involve raw or dilute sampling. Make sure continuous sampling...
Commutability of Cytomegalovirus WHO International Standard in Different Matrices
Jones, Sara; Webb, Erika M.; Barry, Catherine P.; Choi, Won S.; Abravaya, Klara B.; Schneider, George J.
2016-01-01
Commutability of quantitative standards allows patient results to be compared across molecular diagnostic methods and laboratories. This is critical to establishing quantitative thresholds for use in clinical decision-making. A matrix effect associated with the 1st cytomegalovirus (CMV) WHO international standard (IS) was identified using the Abbott RealTime CMV assay. A commutability study was performed to compare the CMV WHO IS and patient specimens diluted in plasma and whole blood. Patient specimens showed similar CMV DNA quantitation values regardless of the diluent or extraction procedure used. The CMV WHO IS, on the other hand, exhibited a matrix effect. The CMV concentration reported for the WHO IS diluted in plasma was within the 95% prediction interval established with patient samples. In contrast, the reported DNA concentration of the CMV WHO IS diluted in whole blood was reduced approximately 0.4 log copies/ml, and values fell outside the 95% prediction interval. Calibrating the assay by using the CMV WHO IS diluted in whole blood would introduce a bias for CMV whole-blood quantitation; samples would be reported as having higher measured concentrations, by approximately 0.4 log IU/ml. Based on the commutability study with patient samples, the RealTime CMV assay was standardized based on the CMV WHO IS diluted in plasma. A revision of the instructions for use of the CMV WHO IS should be considered to alert users of the potential impact from the diluent matrix. The identification of a matrix effect with the CMV WHO IS underscores the importance of assessing commutability of the IS in order to achieve consistent results across methods. PMID:27030491
Droplet Digital PCR-Based Chimerism Analysis for Primary Immunodeficiency Diseases.
Okano, Tsubasa; Tsujita, Yuki; Kanegane, Hirokazu; Mitsui-Sekinaka, Kanako; Tanita, Kay; Miyamoto, Satoshi; Yeh, Tzu-Wen; Yamashita, Motoi; Terada, Naomi; Ogura, Yumi; Takagi, Masatoshi; Imai, Kohsuke; Nonoyama, Shigeaki; Morio, Tomohiro
2018-04-01
In the current study, we aimed to accurately evaluate donor/recipient or male/female chimerism in samples from patients who underwent hematopoietic stem cell transplantation (HSCT). We designed the droplet digital polymerase chain reaction (ddPCR) for SRY and RPP30 to detect the male/female chimerism. We also developed mutation-specific ddPCR for four primary immunodeficiency diseases. The accuracy of the male/female chimerism analysis using ddPCR was confirmed by comparing the results with those of conventional methods (fluorescence in situ hybridization and short tandem repeat-PCR) and evaluating dilution assays. In particular, we found that this method was useful for analyzing small samples. Thus, this method could be used with patient samples, especially to sorted leukocyte subpopulations, during the early post-transplant period. Four mutation-specific ddPCR accurately detected post-transplant chimerism. ddPCR-based male/female chimerism analysis and mutation-specific ddPCR were useful for all HSCT, and these simple methods contribute to following the post-transplant chimerism, especially in disease-specific small leukocyte fractions.
NASA Astrophysics Data System (ADS)
Zhao, Tiejun; Li, Xiaojie; Lee, John H. S.; Yan, Honghao
2018-02-01
Using ferrocene, H2 and O2, Carbon nanomaterials were prepared with gaseous detonation (deflagration) method. The effects of H2 on the phase and morphology of carbon nanomaterials were studied by various proportions of H2 in the reaction. The prepared samples were characterized by x-ray diffractometer, transmission electron microscope and Raman spectrometer. The results show that hydrogen proportion has a great influence on the phase and morphology of carbon nanomaterials. The high hydrogen proportion leads to much unreacted hydrogen, which could protect the iron atom from oxidation of carbon and dilute the reactants contributing to uniform particle size. In addition, the graphitization degree of multi-walled carbon nanotubes, observed in samples with high H2 proportion, is high enough to see the lattice fringes, but the degree of graphitization of whole sample is lower than which fabricated with low H2 proportion, and it may result from the low energy generation.
NASA Astrophysics Data System (ADS)
Mota, Mariana F. B.; Gama, Ednilton M.; Rodrigues, Gabrielle de C.; Rodrigues, Guilherme D.; Nascentes, Clésia C.; Costa, Letícia M.
2018-01-01
In this work, a dilute-and-shoot method was developed for Ca, P, S and Zn determination in new and used lubricating oil samples by total reflection X-ray fluorescence (TXRF). The oil samples were diluted with organic solvents followed by addition of yttrium as internal standard and the TXRF measurements were performed after solvent evaporation. The method was optimized using an interlaboratorial reference material. The experimental parameters evaluated were sample volume (50 or 100 μL), measurement time (250 or 500 s) and volume deposited on the quartz glass sample carrier (5 or 10 μL). All of them were evaluated and optimized using xylene, kerosene and hexane. Analytical figures of merit (accuracy, precision, limit of detection and quantification) were used to evaluate the performance of the analytical method for all solvents. The recovery rates varied from 99 to 111% and the relative standard deviation remained between 1.7% and 10% (n = 8). For all elements, the results obtained by applying the new method were in agreement with the certified value. After the validation step, the method was applied for Ca, P, S and Zn quantification in eight new and four used lubricating oil samples, for all solvents. The concentration of the elements in the samples varied in the ranges of 1620-3711 mg L- 1 for Ca, 704-1277 mg L- 1 for P, 2027-9147 mg L- 1 for S, and 898-1593 mg L- 1 for Zn. The association of TXRF with a dilute-and-shoot sample preparation strategy was efficient for Ca, P, S and Zn determination in lubricating oils, presenting accurate results. Additionally, the time required for analysis is short, the reagent volumes are low minimizing waste generation, and the technique does not require calibration curves.
A comparison of pre- and post-remediation water quality, Mineral Creek, Colorado
Runkel, R.L.; Bencala, K.E.; Kimball, B.A.; Walton-Day, K.; Verplanck, P.L.
2009-01-01
Pre- and post-remediation data sets are used herein to assess the effectiveness of remedial measures implemented in the headwaters of the Mineral Creek watershed, where contamination from hard rock mining has led to elevated metal concentrations and acidic pH. Collection of pre- and post-remediation data sets generally followed the synoptic mass balance approach, in which numerous stream and inflow locations are sampled for the constituents of interest and estimates of streamflow are determined by tracer dilution. The comparison of pre- and post-remediation data sets is confounded by hydrologic effects and the effects of temporal variation. Hydrologic effects arise due to the relatively wet conditions that preceded the collection of pre-remediation data, and the relatively dry conditions associated with the post-remediation data set. This difference leads to a dilution effect in the upper part of the study reach, where pre-remediation concentrations were diluted by rainfall, and a source area effect in the lower part of the study reach, where a smaller portion of the watershed may have been contributing constituent mass during the drier post-remediation period. A second confounding factor, temporal variability, violates the steady-state assumption that underlies the synoptic mass balance approach, leading to false identification of constituent sources and sinks. Despite these complications, remedial actions completed in the Mineral Creek headwaters appear to have led to improvements in stream water quality, as post-remediation profiles of instream load are consistently lower than the pre-remediation profiles over the entire study reach for six of the eight constituents considered (aluminium, arsenic, cadmium, copper, iron, and zinc). Concentrations of aluminium, cadmium, copper, lead, and zinc remain above chronic aquatic-life standards, however, and additional remedial actions may be needed. Future implementations of the synoptic mass balance approach should be preceded by an assessment of temporal variability, and modifications to the synoptic sampling protocol should be made if necessary.
Rapid detection of semenogelin by one-step immunochromatographic assay for semen identification.
Sato, Itaru; Kojima, Koichiro; Yamasaki, Tadashi; Yoshida, Kaoru; Yoshiike, Miki; Takano, Shoichi; Mukai, Toshiji; Iwamoto, Teruaki
2004-04-01
To identify semen in forensic samples, we developed an analytical system for one-step immunoassay that has been constructed using the concept of immunochromatography and can identify semenogelin (Sg), which originates in the seminal vesicles. The system employed monoclonal antibody (mAb) and polyclonal antibody (pAb) against recombinant Sg-II (63 kDa), which has been synthesized in insect cells using baculovirus. The two antibodies bound with the seminal plasma motility inhibitor (SPMI; 14 kDa) as a final fragment peptide of Sg. The test stick is based on the sandwich technique using the above antibodies. When serial dilutions of seminal plasma were analyzed using this test stick, the intensity of a clear immunoreactive signal peaked at 2000-fold dilution. Thereafter, the signals decreased slowly but still persisted up to 400,000-fold dilution. The Sg antigen was undetectable in saliva, urine, breast milk, serum or vaginal secretions. Also, the test stick shown did not react with animal semen samples, such as those from horses, dogs, swine and bulls. When semen samples, diluted 100,000-fold from 100 men were tested, the Sg antigenic activity was detectable in all samples. In addition, the specificity and sensitivity of the test stick for identification of semen were demonstrated by comparative forensic studies. We conclude that this immunoassay method is a useful confirmatory test for the identification of semen. The immunochromatographic system for forensic testing or research use will become available commercially soon.
NASA Astrophysics Data System (ADS)
Shahrestani, Shahed; Mokhtari, Ahmad Reza
2017-04-01
Stream sediment sampling is a well-known technique used to discover the geochemical anomalies in regional exploration activities. In an upstream catchment basin of stream sediment sample, the geochemical signals originating from probable mineralization could be diluted due to mixing with the weathering material coming from the non-anomalous sources. Hawkes's equation (1976) was an attempt to overcome the problem in which the area size of catchment basin was used to remove dilution from geochemical anomalies. However, the metal content of a stream sediment sample could be linked to several geomorphological, sedimentological, climatic and geological factors. The area size is not itself a comprehensive representative of dilution taking place in a catchment basin. The aim of the present study was to consider a number of geomorphological factors affecting the sediment supply, transportation processes, storage and in general, the geochemistry of stream sediments and their incorporation in the dilution correction procedure. This was organized through employing the concept of sediment yield and sediment delivery ratio and linking such characteristics to the dilution phenomenon in a catchment basin. Main stream slope (MSS), relief ratio (RR) and area size (Aa) of catchment basin were selected as the important proxies (PSDRa) for sediment delivery ratio and then entered to the Hawkes's equation. Then, Hawkes's and new equations were applied on the stream sediment dataset collected from Takhte-Soleyman district, west of Iran for Au, As and Sb values. A number of large and small gold, antimony and arsenic mineral occurrences were used to evaluate the results. Anomaly maps based on the new equations displayed improvement in anomaly delineation taking the spatial distribution of mineral deposits into account and could present new catchment basins containing known mineralization as the anomaly class, especially in the case of Au and As. Four catchment basins having Au and As mineralization were added to anomaly class and also one catchment basin with known As occurrence was highlighted as anomalous using new approach. The results demonstrated the usefulness of considering geomorphological parameters in dealing with dilution phenomenon in a catchment basin.
Heit, C; Martin, S J; Yang, F; Inglis, D L
2018-06-01
Volatile acidity (VA) production along with gene expression patterns, encoding enzymes involved in both acetic acid production and utilization, were investigated to relate gene expression patterns to the production of undesired VA during Icewine fermentation. Icewine juice and diluted Icewine juice were fermented using the Saccharomyces cerevisiae wine yeast K1-V1116. Acetic acid production increased sixfold during the Icewine fermentation vs the diluted juice condition, while ethyl acetate production increased 2·4-fold in the diluted fermentation relative to the Icewine. Microarray analysis profiled the transcriptional response of K1-V1116 under both conditions. ACS1 and ACS2 were downregulated 19·0-fold and 11·2-fold, respectively, in cells fermenting Icewine juice compared to diluted juice. ALD3 expression was upregulated 14·6-fold, and gene expressions involved in lipid and ergosterol synthesis decreased during Icewine fermentation. Decreased expression of ACS1 and ACS2 together with increased ALD3 expression contributes to the higher acetic acid and lower ethyl acetate levels generated by K1-V1116 fermenting under hyperosmotic stress. This work represents a more comprehensive understanding of how and why commercial wine yeast respond at the transcriptional and metabolic level during fermentation of Icewine juice, and how these responses contribute to increased acetic acid and decreased ethyl acetate production. © 2018 The Society for Applied Microbiology.
NASA Technical Reports Server (NTRS)
Alexander, Donita; DePaola, Angelo; Young, Ronald B.
1998-01-01
The disease cholera, caused by Vibrio cholerae, has been associated with consumption of contaminated seafood, including raw oysters. Detection of V. cholerae in foods typically involves blending the oysters, diluting the homogenate in alkaline peptone water (APW), overnight enrichment, and isolation on selective agar. Unfortunately, the oyster homogenate must be diluted to large volumes because lower dilutions inhibit the growth of V. cholerae. The goals of this study were to develop an alternative to large dilutions and to evaluate the basis for the inhibition observed in lower dilutions of oyster homogenates. Centrifugation of oyster homogenates at 10,000 x g for 15 min, followed by enrichment of the resulting pellet in APW, was found to eliminate the inhibition of V. cholerae growth. Inhibition appears not to be due to competing microflora but to a component(s) released when V. cholerae grows in the presence of oyster homogenate. The inhibitory component(s) kills the V. cholerae after the cell concentration reaches > 10(exp 8) cells/mL, rather than initially preventing their growth. The pH also declines from 8.0 to 5.5 during this period; however, the pH decline by itself appears not to cause V. cholerae death. Seven strains of V. cholerae (01 and non-01) and two strains of V. vulnificus were susceptible to the inhibitory agent(s). However, other Vibrio and non-Vibrio species tested were not inhibited by the oyster homogenates. Based on digestion of oyster homogenates with pronase, trypsin and lipase, the inhibitory reaction involves a protein(s). In a preliminary trial with oyster homogenate seeded with 1 cfu/g of V. cholerae, the modified centrifugation technique detected a slightly higher percentage of samples at a 1:10 dilution than the standard FDA Bacteriological Analytical Method (BAM) detected in uncentrifuged oyster homogenate at a 1:100 dilution. V. cholerae in seeded samples could also be detected more frequently by the modified centrifugation method than by PCR at a 1:10 dilution.
40 CFR 1065.546 - Validation of minimum dilution ratio for PM batch sampling.
Code of Federal Regulations, 2011 CFR
2011-07-01
... the raw exhaust flow rate based on the measured intake air molar flow rate and the chemical balance..., fuel rate measurements, and fuel properties, consistent with good engineering judgment. (b) Determine...) and dilute exhaust corrected for any removed water. (c) Use good engineering judgment to develop your...
Assay dilution factors confound measures of total antioxidant capacity in polyphenol-rich juices
USDA-ARS?s Scientific Manuscript database
The extent to which sample dilution factor (DF) affects Total Antioxidant Capacity (TAC) values is poorly understood. Thus, we examined the impact of DF on the ORAC, FRAP, DPPH, and Total Phenols (TP) assays using pomegranate juice (PJ), grape juice (GJ), selected flavonoids, ascorbic acid, and ella...
Jo, Yun Hee; Shin, Wan Gyoon; Lee, Ju-Yeun; Yang, Bo Ram; Yu, Yun Mi; Jung, Sun Hoi; Kim, Hyang Sook
2016-10-01
There are very few studies reporting the impact of providing intravenous (IV) preparation information on quality use of antimicrobials, particularly regarding their reconstitution and dilution. Therefore, to improve these processes in IV antimicrobial administration, an IV preparation information system (IPIS) was implemented in a hospital. We aimed to evaluate the effect of improving reconstitution and dilution by implementing an IPIS in the electronic medical record (EMR) system. Prescriptions and activity records of nurses for injectable antimicrobials that required reconstitution and dilution for IV preparation from January 2008 to December 2013 were retrieved from EMR, and assessed based on packaging label information for reconstituting and diluting solutions. We defined proper reconstitution and dilution as occurring when the reconstitution and dilution solutions prescribed were consistent with the nurses' acting records. The types of intervention in the IPIS were as follows: a pop-up alert for proper reconstitution and passive guidance for proper dilution. We calculated the monthly proper reconstitution rate (PRR) and proper dilution rate (PDR) and evaluated the changes in these rates and trends using interrupted time series analyses. Prior to the initiation of the reconstitution alert and dilution information, the PRR and PDR were 12.7 and 46.1%, respectively. The reconstitution alert of the IPIS rapidly increased the PRR by 41% (p<0.001), after which the PRR decreased by 0.9% (p=0.013) per month after several months. However, there was no significant change in the rate or trend of the PDR during the study period. This study demonstrated that the provision of reconstitution alerts by the IPIS contributed to improving the reconstitution process of IV antimicrobial injection administration. However, providing passive information on dilution solutions was ineffective. Furthermore, solutions to ensure the continuous effectiveness of alert systems are warranted and should be actively sought. Copyright © 2016. Published by Elsevier Ireland Ltd.
L-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array
DOE Office of Scientific and Technical Information (OSTI.GOV)
Titus, Charles J.; Baker, Michael L.; Lee, Sang Jun
Here, we present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements then demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100–2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique abilitymore » to characterize frozen solutions of radiation- and temperature-sensitive samples.« less
L-edge spectroscopy of dilute, radiation-sensitive systems using a transition-edge-sensor array
Titus, Charles J.; Baker, Michael L.; Lee, Sang Jun; ...
2017-12-07
Here, we present X-ray absorption spectroscopy and resonant inelastic X-ray scattering (RIXS) measurements on the iron L-edge of 0.5 mM aqueous ferricyanide. These measurements then demonstrate the ability of high-throughput transition-edge-sensor (TES) spectrometers to access the rich soft X-ray (100–2000 eV) spectroscopy regime for dilute and radiation-sensitive samples. Our low-concentration data are in agreement with high-concentration measurements recorded by grating spectrometers. These results show that soft-X-ray RIXS spectroscopy acquired by high-throughput TES spectrometers can be used to study the local electronic structure of dilute metal-centered complexes relevant to biology, chemistry, and catalysis. In particular, TES spectrometers have a unique abilitymore » to characterize frozen solutions of radiation- and temperature-sensitive samples.« less
NASA Astrophysics Data System (ADS)
Sukigara, Chiho; Mino, Yoshihisa; Tripathy, Sarat Chandra; Ishizaka, Joji; Matsuno, Takeshi
2017-12-01
Intensive surveys with repeated CTD and microstructure turbulent observations, water and sediments sampling as well as onboard incubation and sediment trap experiments were conducted to reveal the nitrogen budget in the center of the East China Sea (ECS) during July 2010 and 2011. Low salinity water (Changjiang Diluted Water, CDW) covered the study area in 2010, but not in 2011. Higher chlorophyll a (chl. a) concentration, primary productivity, and downward particle flux in the upper layer were observed in 2010 than those in 2011. Existence of the CDW resulted in a steep pycnocline and an associated subsurface chl. a maximum (SCM) layer directly beneath the CDW. From chemical analyses of particulate carbon and nitrogen contents and isotope ratios, it became apparent that the particles sunk out the euphotic zone in 2010 was primarily originated in the CDW layer and secondly in the SCM layer. Whereas, in 2011, sinking particles were originated in the surface layer but a part of them were decomposed in the bottom of pycnocline. Our findings indicate that the CDW would supply particles into the deep layer and contribute to the downward transport of materials and the efficiency of biological pump in the ECS.
Lawrence, Matthew James; Marsden, Nick; Kaczynski, Jakub; Davies, Gareth; Davies, Nia; Hawkins, Karl; Perumal, Sounder; Brown, Martin Rowan; Morris, Keith; Davidson, Simon J; Williams, Phylip Rhodri; Evans, Phillip Adrian
2016-11-01
Balancing the beneficial effects of resuscitation fluids against their detrimental effect on hemostasis is an important clinical issue. We aim to compare the in vitro effects of 3 different colloid resuscitation fluids (4.5% albumin, hydroxyethyl starch [Voluven 6%], and gelatin [Geloplasma]) on clot microstructure formation using a novel viscoelastic technique, the gel point. This novel hemorheologic technique measures the biophysical properties of the clot and provides an assessment of clot microstructure from its viscoelastic properties. Importantly, in contrast to many assays in routine clinical use, the measurement is performed using unadulterated whole blood in a near-patient setting and provides rapid assessment of coagulation. We hypothesized that different colloids will have a lesser or greater detrimental effect on clot microstructure formation when compared against each other. Healthy volunteers were recruited into the study (n = 104), and a 20-mL sample of whole blood was obtained. Each volunteer was assigned to 1 of the 3 fluids, and the sample was diluted to 1 of 5 different dilutions (baseline, 10%, 20%, 40%, and 60%). The blood was tested using the gel point technique, which measures clot mechanical strength and quantifies clot microstructure (df) at the incipient stages of fibrin formation. df and clot mechanical strength decrease with progressive dilution for all 3 fluids. A significant reduction in df from baseline was recorded at dilutions of 20% for albumin (P < .0001), 40% for starch (P < .0001), and 60% for gelatin (P < .0001). We also observed significant differences, in terms of df, when comparing the different types of colloid (P < .0001). We found that albumin dilution produced the largest changes in clot microstructure, providing the lowest values of df (= 1.41 ± 0.061 at 60% dilution) compared with starch (1.52 ± 0.081) and gelatin (1.58 ± 0.063). We show that dilution with all 3 fluids has a significant effect on coagulation at even relatively low dilution volumes (20% and 40%). Furthermore, we quantify, using a novel viscoelastic technique, how the physiochemical properties of the 3 colloids exert individual changes on clot microstructure.
Biodiesel Impact on Engine Lubricant Dilution During Active Regeneration of Aftertreatment Systems
DOE Office of Scientific and Technical Information (OSTI.GOV)
He, X.; Williams, A.; Christensen, E.
Experiments were conducted with ultra low sulfur diesel (ULSD) and 20% biodiesel blends (B20) to compare lube oil dilution levels and lubricant properties for systems using late in-cylinder fuel injection for aftertreatment regeneration. Lube oil dilution was measured by gas chromatography (GC) following ASTM method D3524 to measure diesel content, by Fourier transform infrared (FTIR) spectrometry following a modified ASTM method D7371 to measure biodiesel content, and by a newly developed back-flush GC method that simultaneously measures both diesel and biodiesel. Heavy-duty (HD) engine testing was conducted on a 2008 6.7L Cummins ISB equipped with a diesel oxidation catalyst (DOC)more » and diesel particle filter (DPF). Stage one of engine testing consisted of 10 consecutive repeats of a forced DPF regeneration event. This continuous operation with late in-cylinder fuel injection served as a method to accelerate lube-oil dilution. Stage two consisted of 16 hours of normal engine operation over a transient test cycle, which created an opportunity for any accumulated fuel in the oil sump to evaporate. Light duty (LD) vehicle testing was conducted on a 2010 VW Jetta equipped with DOC, DPF and a NOx storage catalyst (NSC). Vehicle testing comprised approximately 4,000 miles of operation on a mileage-accumulation dynamometer (MAD) using the U.S. Environmental Protection Agency's Highway Fuel Economy Cycle because of the relatively low engine oil and exhaust temperatures, and high DPF regeneration frequency of this cycle relative to other cycles examined. Comparison of the lube oil dilution analysis methods suggests that D3524 does not measure dilution by biodiesel. The new back-flush GC method provided analysis for both diesel and biodiesel, in a shorter time and with lower detection limit. Thus all lube oil dilution results in this paper are based on this method. Analysis of the HD lube-oil samples showed only 1.5% to 1.6% fuel dilution for both fuels during continuous operation under DPF regeneration events. During the second stage of HD testing, the ULSD lube-oil dilution levels fell from 1.5% to 0.8%, while for B20, lube-oil dilution levels fell from 1.6% to 1.0%, but the fuel in the oil was 36% biodiesel. For the LD vehicle tests, the frequency of DPF regeneration events was observed to be the same for both ULSD and B20. No significant difference between the two fuels' estimated soot loading was detected by the engine control unit (ECU), although a 23% slower rate of increase in differential pressure across DPF was observed with B20. It appears that the ECU estimated soot loading is based on the engine map, not taking advantage of the lower engine-out particulate matter from the use of biodiesel. After 4,000 miles of LD vehicle operation with ULSD, fuel dilution in the lube-oil samples showed total dilution levels of 4.1% diesel. After 4,000 miles of operation with B20, total fuel in oil dilution levels were 6.7% consisting of 3.6% diesel fuel and 3.1% biodiesel. Extrapolation to the 10,000-mile oil drain interval with B20 suggests that the total fuel content in the oil could reach 12%, compared to 5% for operation on ULSD. Analysis of the oil samples also included measurement of total acid number, total base number, viscosity, soot, metals and wear scar; however, little difference in these parameters was noted.« less
Determination of the viscosity number of thermoplastics in dilute solution; polyamides (PA)
NASA Technical Reports Server (NTRS)
1985-01-01
This West German Standard presents a test used to determine the viscosity number of polyamides and copolyamides which are easily diluted in sulfuric acid, and for other polyamides which are less easily diluted in sulfuric acid, and which are diluted in m-cresol. As formic acid is often used in industry instead of sulfuric acid, this solvent is also presented as an alternative, however, sulfuric acid is preferred because of the thermodynamic solubility characteristics of the polyamides and the handling safety. In addition, it is shown which solvent should be used for each polyamide. Finally, determinations concerning the preparation of the samples are presented. Using the viscosity number, a determination of the molar mass of the polyamides is possible.
Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration
Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang
2015-01-01
Background The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. Methods During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Results Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. Conclusions The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease. PMID:26353117
Diagnostic Accuracy of Urine Protein/Creatinine Ratio Is Influenced by Urine Concentration.
Yang, Chih-Yu; Chen, Fu-An; Chen, Chun-Fan; Liu, Wen-Sheng; Shih, Chia-Jen; Ou, Shuo-Ming; Yang, Wu-Chang; Lin, Chih-Ching; Yang, An-Hang
2015-01-01
The usage of urine protein/creatinine ratio to estimate daily urine protein excretion is prevalent, but relatively little attention has been paid to the influence of urine concentration and its impact on test accuracy. We took advantage of 24-hour urine collection to examine both urine protein/creatinine ratio (UPCR) and daily urine protein excretion, with the latter as the reference standard. Specific gravity from a concomitant urinalysis of the same urine sample was used to indicate the urine concentration. During 2010 to 2014, there were 540 adequately collected 24h urine samples with protein concentration, creatinine concentration, total volume, and a concomitant urinalysis of the same sample. Variables associated with an accurate UPCR estimation were determined by multivariate linear regression analysis. Receiver operating characteristic (ROC) curves were generated to determine the discriminant cut-off values of urine creatinine concentration for predicting an accurate UPCR estimation in either dilute or concentrated urine samples. Our findings indicated that for dilute urine, as indicated by a low urine specific gravity, UPCR is more likely to overestimate the actual daily urine protein excretion. On the contrary, UPCR of concentrated urine is more likely to result in an underestimation. By ROC curve analysis, the best cut-off value of urine creatinine concentration for predicting overestimation by UPCR of dilute urine (specific gravity ≦ 1.005) was ≦ 38.8 mg/dL, whereas the best cut-off values of urine creatinine for predicting underestimation by UPCR of thick urine were ≧ 63.6 mg/dL (specific gravity ≧ 1.015), ≧ 62.1 mg/dL (specific gravity ≧ 1.020), ≧ 61.5 mg/dL (specific gravity ≧ 1.025), respectively. We also compared distribution patterns of urine creatinine concentration of 24h urine cohort with a concurrent spot urine cohort and found that the underestimation might be more profound in single voided samples. The UPCR in samples with low or high specific gravity is more likely to overestimate or underestimate actual daily urine protein amount, respectively, especially in a dilute urine sample with its creatinine below 38.8 mg/dL or a concentrated sample with its creatinine above 61.5 mg/dL. In particular, UPCR results should be interpreted with caution in cases that involve dilute urine samples because its overestimation may lead to an erroneous diagnosis of proteinuric renal disease or an incorrect staging of chronic kidney disease.
NASA Astrophysics Data System (ADS)
Pfisterer, Kaylen J.; Amelard, Robert; Wong, Alexander
2018-02-01
Dysphagia (swallowing difficulty) increases risk for malnutrition and affects at least 15% of American older adults, and 590 million people worldwide. Malnutrition is associated with increased mortality, increased morbidity, decreased quality of life, and accounts for over $15 billion (USD) health-care related costs each year. While modified texture diets (e.g., puréed food) reduce the risk of choking, quality assurance is necessary for monitoring nutrient density to ensure food meets nutritional requirements. However, current methods are subjective and time consuming. The purpose of this study was to investigate the feasibility of optical techniques for an objective assessment of food nutrient density in puréed samples. Motivated by a theoretical optical dilution model, broadband spectral images of commercially prepared purée samples were acquired. Specifically, 13 flavors at five dilutions relative to initial concentration, each with six replicates, were acquired for a total of 390 samples. Purée samples were prepared and loaded onto a white reflectance back plane to maximize photon traversal path length through the purée. The sample was illuminated with a tungsten-halogen illumination source fitted with a front glass fabric diffuser for spatially homogeneous illumination. This broadband illuminant was chosen to observe as many food-light spectral absorbance interactions as possible. Flavor-stratified correlation analysis was performed on this food image dataset to investigate the relationship between nutritional information and color space transformations. A special case of blueberry is presented as the effect of anthocyanins was quantitatively observed through normalized spectral trends in response to pH perturbations across dilutions.
Alcántara-Durán, Jaime; Moreno-González, David; Beneito-Cambra, Miriam; García-Reyes, Juan F
2018-05-15
In this work, a sensitive nanoflow liquid chromatography high-resolution mass spectrometry screening method has been developed for the determination of multiclass drugs of abuse and sport drugs in human urine. 81 drugs belonging to different multiclass pharmaceuticals were targeted. The method is based on the use of a nanoLC column (75 µm × 150 mm, 3 µm particle size and 100 Å pore) with the nanospray emitter tip integrated so that dead volumes are significantly minimized. Data acquisition method included both full-scan and all ion fragmentation experiments using an Orbitrap analyser (Q-Exactive) operated in the positive ionization mode. To increase laboratory throughput, a dilute-and-shoot methodology has been tested and proposed, based solely on direct urine dilution without further sample workup. Matrix effects were evaluated, showing a negligible effect for all studied compounds when a dilution 1:50 was implemented. Despite this high-dilution factor, limits of quantification were still satisfactory, with values below 5 µg L -1 in most cases, being lower than their minimum required performance limits correspond established by the World Anti-Doping Agency. Therefore, the use of the dilute-and-shoot method with the enhanced sensitivity provided by nanoflow LC setup could be useful tool for the determination of studied compounds in drug testing, thus increasing laboratory performance, because a minimum sample treatment steps are required. Copyright © 2018 Elsevier B.V. All rights reserved.
40 CFR 1066.110 - Equipment specifications for emission sampling systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
..., such as orifice plates or fins, to achieve good mixing; this may be necessary for good mixing if Re# is... condensation. (v) If you choose to dilute the exhaust by using a remote mix tee, which dilutes the exhaust at... polymer-based materials. (D) Use good engineering judgment to ensure that the materials you choose do not...
Arning, Erland; Bottiglieri, Teodoro
2016-01-01
We describe a simple stable isotope dilution method for accurate and precise measurement of γ-aminobutyric acid (GABA), a major inhibitory neurotransmitter in human cerebrospinal fluid (CSF) as a clinical diagnostic test. Determination of GABA in CSF (50 μL) was performed utilizing high performance liquid chromatography coupled with electrospray positive ionization tandem mass spectrometry (HPLC-ESI-MS/MS). Analysis of free and total GABA requires two individual sample preparations and mass spectrometry analyses. Free GABA in CSF is determined by a 1:2 dilution with internal standard (GABA-D2) and injected directly onto the HPLC-ESI-MS/MS system. Determination of total GABA in CSF requires additional sample preparation in order to hydrolyze all the bound GABA in the sample to the free form. This requires hydrolyzing the sample by boiling in acidic conditions (hydrochloric acid) for 4 h. The sample is then further diluted 1:10 with a 90 % acetonitrile/0.1 % formic acid solution and injected into the HPLC-ESI-MS/MS system. Each assay is quantified using a five-point standard curve and is linear from 6 nM to 1000 nM and 0.63 μM to 80 μM for free and total GABA, respectively.
da Costa, Wiviane Kássia Oliveira Correia; da Silva, Caroline Santos; Figueiredo, José Fernando Dagnone; Nóbrega, Joaquim Araujo; Paim, Ana Paula Silveira
2018-06-05
A fast and simple dilute-and-shoot procedure for determination of Al, As, Ba, Cd, Cu, Fe, Mg, Mn, Ni, Pb, Sc, Ti, V, Zn and Zr in deodorants by inductively coupled plasma optical emission spectrometry (ICP OES) was developed. Sample preparation was carried out by diluting 1 mL of deodorant sample in 1% (v v -1 ) HNO 3 . The accuracy of the analytical procedure was evaluated using addition and recovery experiments, and recoveries ranged from 80 to 119%. The limits of detection varied from 0.001 to 0.76 mg kg -1 . Nine deodorants samples of different brands were analyzed. The maximum concentrations found (mg kg -1 ) were: Fe (1.0), Mn (0.1), Ti (1.02), V (0.33), Zn (255.2) and Zr (0.5); for Al and Mg, determined concentrations varied from 0.01 to 7.0% and from 0.005 to 1.44 mg kg -1 , respectively, showing wide variation depending on the sample type. The developed procedure was adequate for determining these analytes in routine analysis presenting high sample throughput and demonstrated the feasibility of direct analysis measurements after simple dilution step. Copyright © 2018 Elsevier B.V. All rights reserved.
Electrostatic charge characteristics of jet nebulized aerosols.
Kwok, Philip Chi Lip; Trietsch, Sebastiaan J; Kumon, Michiko; Chan, Hak-Kim
2010-06-01
Liquid droplets can be spontaneously charged in the absence of applied electric fields by spraying. It has been shown by computational simulation that charges may influence particle deposition in the airways. The electrostatic properties of jet nebulized aerosols and their potential effects on lung deposition have hardly been studied. A modified electrical low pressure impactor (ELPI) was employed to characterize the aerosol charges generated from jet nebulized commercial products. The charge and size measurements were conducted at 50% RH and 22 degrees C with a modified ELPI. Ventolin, Bricanyl, and Atrovent were nebulized using PARI LC Plus jet nebulizers coupled to a DeVilbiss Pulmo-Aide compressor. The aerosols were sampled in 30-sec durations. The drug deposits on the impactor stages were assayed chemically using high-performance liquid chromatography (HPLC). The charges of nebulized deionized water, isotonic saline, and the three commercial products diluted with saline were also measured to analyze the contributions of the major nebule ingredients on charging. No mass assays were performed on these runs. All three commercial nebules generated net negative charges. The magnitude of the charges reduced over the period of nebulization. Ventolin and Bricanyl yielded similar charge profiles. Highly variable charges were produced from deionized water. On the other hand, nebulized saline reproducibly generated net positive charges. Diluted commercial nebules showed charge polarity inversion. The charge profiles of diluted salbutamol and terbutaline solutions resembled those of saline, while the charges from diluted ipratropium solutions fluctuated near neutrality. The charge profiles were shown to be influenced by the concentration and physicochemical properties of the drugs, as well as the history of nebulization. The drugs may have unique isoelectric concentrations in saline at which the nebulized droplets would carry near-zero charges. According to results from computational simulation models in the literature, the numbers of elementary charges per droplet estimated from the data were not high enough to potentially affect lung deposition.
Processing of aerosol particles within the Habshan pollution plume
NASA Astrophysics Data System (ADS)
Semeniuk, T. A.; Bruintjes, R.; Salazar, V.; Breed, D.; Jensen, T.; Buseck, P. R.
2015-03-01
The Habshan industrial site in the United Arab Emirates produces a regional-scale pollution plume associated with oil and gas processing, discharging high loadings of sulfates and chlorides into the atmosphere, which interact with the ambient aerosol population. Aerosol particles and trace gas chemistry at this site were studied on two flights in the summer of 2002. Measurements were collected along vertical plume profiles to show changes associated with atmospheric processing of particle and gas components. Close to the outlet stack, particle concentrations were over 10,000 cm-3, dropping to <2000 cm-3 in more dilute plume around 1500 m above the stack. Particles collected close to the stack and within the dilute plume were individually measured for size, morphology, composition, and mixing state using transmission electron microscopy coupled with energy-dispersive X-ray spectroscopy. Close to the stack, most coarse particles consisted of mineral dust and NaCl crystals from burning oil brines, while sulfate droplets dominated the fine mode. In more dilute plume, at least 1500 m above the stack, the particle spectrum was more diverse, with a significant increase in internally mixed particle types. Dilute plume samples consisted of coarse NaCl/silicate aggregates or NaCl-rich droplets, often with a sulfate component, while fine-fraction particles were of mixed cation sulfates, also internally mixed with nanospherical soot or silicates. Thus, both chloride and sulfate components of the pollution plume rapidly reacted with ambient mineral dust to form coated and aggregate particles, enhancing particle size, hygroscopicity, and reactivity of the coarse mode. The fine-fraction sulfate-bearing particles formed in the plume contribute to regional transport of sulfates, while coarse sulfate-bearing fractions locally reduced the SO2 loading through sedimentation. The chloride- and sulfate-bearing internally mixed particles formed in the plume markedly changed the reflectivity and scattering properties of the ambient aerosol population, as well as its hygroscopic and ice nucleation properties.
Misra, S; Zhou, B B; Drozdov, I K; Seo, J; Urban, L; Gyenis, A; Kingsley, S C J; Jones, H; Yazdani, A
2013-10-01
We describe the construction and performance of a scanning tunneling microscope capable of taking maps of the tunneling density of states with sub-atomic spatial resolution at dilution refrigerator temperatures and high (14 T) magnetic fields. The fully ultra-high vacuum system features visual access to a two-sample microscope stage at the end of a bottom-loading dilution refrigerator, which facilitates the transfer of in situ prepared tips and samples. The two-sample stage enables location of the best area of the sample under study and extends the experiment lifetime. The successful thermal anchoring of the microscope, described in detail, is confirmed through a base temperature reading of 20 mK, along with a measured electron temperature of 250 mK. Atomically resolved images, along with complementary vibration measurements, are presented to confirm the effectiveness of the vibration isolation scheme in this instrument. Finally, we demonstrate that the microscope is capable of the same level of performance as typical machines with more modest refrigeration by measuring spectroscopic maps at base temperature both at zero field and in an applied magnetic field.
Gono, Takahisa; Okazaki, Yuka; Murakami, Akihiro; Kuwana, Masataka
2018-04-09
To compare the quantitative performance for measuring anti-MDA5 antibody titer of two enzyme-linked immunosorbent assay (ELISA) systems: an in-house ELISA and the commercial MESACUP TM anti-MDA5 test. Anti-MDA5 antibody titer was measured in sera from 70 patients with dermatomyositis using an in-house ELISA and the MESACUP TM anti-MDA5 test side-by-side. For the commercial ELISA kit, serum samples diluted 1:101 were used according to the manufacturer's protocol, but serial dilutions of sera were also examined to identify the optimal serum dilution for quantification. The anti-MDA5 antibody titers measured by the in-house and commercial ELISAs were positively correlated with each other (r = 0.53, p = .0001), but the antibody titer measured by the commercial ELISA was less sensitive to change after medical treatment, and 37 (80%) of 46 anti-MDA5-positive sera had antibody titer exceeding the quantification range specified by the manufacturer (≥150 index). Experiments using diluted serum samples revealed that diluting the sera 1:5050 improved the quantitative performance of the MESACUP TM anti-MDA5 test, including a better correlation with the in-house ELISA results and an increased sensitivity to change. We improved the ability of the commercial ELISA kit to quantify anti-MDA5 antibody titer by altering its protocol.
Effect of combined physico-chemical processes on the phytotoxicity of olive mill wastewaters.
Andreozzi, Roberto; Canterino, Marisa; Di Somma, Ilaria; Lo Giudice, Roberto; Marotta, Raffaele; Pinto, Gabriele; Pollio, Antonino
2008-03-01
A pool of laboratory experiments is planned with the aim of evaluating the possibility to reduce the phytotoxicity of olive mill wastewater (OMW) with combined physico-chemical processes (centrifugation-ozonation, centrifugation-solar photolysis, centrifugation-solar modified photoFenton, centrifugation-solar modified photoFenton-ozonation). A moderate COD removal of an OMW is reached by using ozonation or solar modified photoFenton separately or solar modified photoFenton/O(3) combined process even for prolonged treatment times. The O(3)-treated OMWs are still toxic towards algal growth (Pseudokirchneriella subcapitata) and only for dilutions equal to or higher than 1:160 a stimulation of algal growth is observed. The sole ozonation does not reduce significantly the phytotoxicity of tested OMW measured through the GI calculation of Raphanus sativus L., Cucumis sativus L. and Lactuca sativa L. A marked reduction of OMW inhibition, higher than 50%, is evidenced for 1:8 dilution OMW samples ozonated for 2h. The long-term storage of OMW associated with solar irradiation without or with Fe(III) ions under continuous aeration is less efficient than ozonation, and the combined action of the two former treatments does not significantly contribute to enhance both COD removal and germination index. Better results are obtained on seed germination and root elongation of plantlets of the three selected species, which germinated on OMW-free solidified medium and were then transferred on a solidified culture medium containing O(3)-treated OMW diluted 1:2 and 1:4. The operating costs are estimated for the solar modified photoFenton-ozonation process.
Schulze, M; Henning, H; Rüdiger, K; Wallner, U; Waberski, D
2013-12-01
Freshly collected boar spermatozoa are sensitive to a fast reduction in temperature because of lipid phase transition and phase separation processes. Temperature management during semen processing may determine the quality of stored samples. The aim of this study was to evaluate the influence of isothermic and hypothermic semen processing protocols on boar sperm quality under laboratory and field conditions. In the laboratory study, ejaculates (n = 12) were first diluted (1:1) with Beltsville Thawing Solution (BTS) at 32 °C, then processed either with isothermic (32 °C) or hypothermic (21 °C) BTS, stored at 17 °C, and assessed on days 1, 3, and 6. Temperature curves showed that 150 minutes after the first dilution, semen doses of both groups reached the same temperature. Two-step hypothermic processing resulted in lower sperm motility on days 1 and 6 (P < 0.05). Concomitantly, hypothermally processed samples contained less membrane intact sperm on days 3 and 6 (P < 0.05). Using AndroStar Plus extender instead of BTS reduced the negative effect of hypothermic processing. In the field study, 15 semen samples from each of 23 European artificial insemination studs were evaluated as part of an external quality control program. Semen quality based on motility, membrane integrity, mitochondrial activity, and a thermoresistance test was higher for stations using one-step isothermic dilutions (n = 7) compared with artificial insemination centers using two-step hypothermic protocols (n = 16). Both studies show that chilling injury associated with hypothermic dilution results in lower quality of stored boar semen compared with isothermic dilution and that the type of semen extender affects the outcomes. Copyright © 2013 Elsevier Inc. All rights reserved.
Removal of lead from aqueous solutions using Cassia grandis seed gum-graft-poly(methylmethacrylate).
Singh, Vandana; Tiwari, Stuti; Sharma, Ajit Kumar; Sanghi, Rashmi
2007-12-15
Using persulfate/ascorbic acid redox system, a series of Cassia grandis seed gum-graft-poly(methylmethacrylate) samples were synthesized. The copolymer samples were evaluated for lead(II) removal from the aqueous solutions where the sorption capacities were found proportional to the grafting extent. The conditions for the sorption were optimized using copolymer sample of highest percent grafting. The sorption was found pH and concentration dependent, pH 2.0 being the optimum value. Adsorption of lead by the grafted seed gum followed a pseudo-second-order kinetics with a rate constant of 4.64 x 10(-5) g/mg/min. The equilibrium data followed the Langmuir isotherm model with maximum sorption capacity of 126.58 mg/g. The influence of electrolytes NaCl, Na(2)SO(4) on lead uptake was also studied. Desorption with 2 N HCl could elute 76% of the lead ions from the lead-loaded copolymer. The regeneration experiments revealed that the copolymer could be successfully reused for at least four cycles though there was a successive loss in lead sorption capacity with every cycle. The adsorbent was also evaluated for Pb(II) removal from battery waste-water containing 2166 mg/L Pb(II). From 1000 times diluted waste water, 86.1% Pb(II) could be removed using 0.05 g/20 ml adsorbent dose, while 0.5 g/20 ml adsorbent dose was capable of removing 60.29% Pb from 10 times diluted waste water. Optimum Pb(II) binding under highly acidic conditions indicated that there was a significant contribution of nonelectrostatic interactions in the adsorption process. A possible mechanism for the adsorption has been discussed.
Magnetic nanoparticles formed in glasses co-doped with iron and larger radius elements
NASA Astrophysics Data System (ADS)
Edelman, I.; Ivanova, O.; Ivantsov, R.; Velikanov, D.; Zabluda, V.; Zubavichus, Y.; Veligzhanin, A.; Zaikovskiy, V.; Stepanov, S.; Artemenko, A.; Curély, J.; Kliava, J.
2012-10-01
A new type of nanoparticle-containing glasses based on borate glasses co-doped with low contents of iron and larger radius elements, Dy, Tb, Gd, Ho, Er, Y, and Bi, is studied. Heat treatment of these glasses results in formation of magnetic nanoparticles, radically changing their physical properties. Transmission electron microscopy and synchrotron radiation-based techniques: x-ray diffraction, extended x-ray absorption fine structure, x-ray absorption near-edge structure, and small-angle x-ray scattering, show a broad distribution of nanoparticle sizes with characteristics depending on the treatment regime; a crystalline structure of these nanoparticles is detected in heat treated samples. Magnetic circular dichroism (MCD) studies of samples subjected to heat treatment as well as of maghemite, magnetite, and iron garnet allow to unambiguously assign the nanoparticle structure to maghemite, independently of co-dopant nature and of heat treatment regime used. Different features observed in the MCD spectra are related to different electron transitions in Fe3+ ions gathered in the nanoparticles. The static magnetization in heat treated samples has non-linear dependence on the magnetizing field with hysteresis. Zero-field cooled magnetization curves show that at higher temperatures the nanoparticles occur in superparamagnetic state with blocking temperatures above 100 K. Below ca. 20 K, a considerable contribution to both zero field-cooled and field-cooled magnetizations occurs from diluted paramagnetic ions. Variable-temperature electron magnetic resonance (EMR) studies unambiguously show that in as-prepared glasses paramagnetic ions are in diluted state and confirm the formation of magnetic nanoparticles already at earlier stages of heat treatment. Computer simulations of the EMR spectra corroborate the broad distribution of nanoparticle sizes found by "direct" techniques as well as superparamagnetic nanoparticle behaviour demonstrated in the magnetization studies.
NASA Astrophysics Data System (ADS)
Boulyga, Sergei F.; Heumann, Klaus G.
2005-04-01
Laser ablation inductively coupled plasma isotope dilution mass spectrometry (LA-ICP-IDMS) with a special laser ablation system for bulk analyses (LINA-Spark(TM)-Atomiser) was applied for direct determinations of chlorine, bromine, and iodine in rock and sediment samples. Special attention was focused on possible inter-halogen fractionations and analyte/spike isotope fractionations by using LA-ICP-MS and LA-ICP-IDMS, respectively. A variation of Br/Cl and I/Cl element intensity ratios by a factor of 1.3-3 was observed when changing the nebulizer gas flow rate in the range of 0.84-1.0 L min-1 and the laser power density in the range of 2-10 GW cm-2, respectively. When using an internal standard for halogen quantification in LA-ICP-MS, this inter-element fractionation can cause systematic errors, which can be avoided by applying the isotope dilution technique. However, at high laser power densities (>5.7 GW cm-2 for iodine and >4.0 GW cm-2 for bromine and chlorine) the corresponding measured isotope ratio of the isotope-diluted sample deviates significantly from the target value. Under optimised conditions concentrations in the range of 30 [mu]g g-1-16 × 103 [mu]g g-1 for chlorine, <2-140 [mu]g g-1 for bromine, and <0.1-31 [mu]g g-1 for iodine were determined by LA-ICP-IDMS in two sediment reference materials (SRM 1646, SRM 2704) and three rock reference samples (GS-N, Granite; BX-N, Bauxite; DT-N, Disthene), which have not been certified for these halogens. The sediment results agree well within the given uncertainties with indicative values by different methods and the results of the rock samples with those obtained by negative thermal ionisation isotope dilution mass spectrometry. The detection limits of LA-ICP-IDMS are 8 [mu]g g-1 for chlorine, 1.7 [mu]g g-1 for bromine, and 0.1 [mu]g g-1 for iodine.
Semenistaya, Ekaterina; Zvereva, Irina; Krotov, Grigory; Rodchenkov, Grigory
2016-09-01
Currently liquid chromatography - mass spectrometry (LC-MS) analysis after solid-phase extraction (SPE) on weak cation-exchange cartridges is a method of choice for anti-doping analysis of small bioactive peptides such as growth hormone releasing peptides (GHRPs), desmoporessin, LHRH, and TB-500 short fragment. Dilution of urine samples with phosphate buffer for pH adjustment and SPE on weak cation exchange microelution plates was tested as a means to increase throughput of this analysis. Dilution using 200 mM phosphate buffer provides good buffering capacity without affecting the peptides recoveries. SPE on microelution plates was performed on Waters Positive Pressure-96 Processor with subsequent evaporation of eluates in nitrogen flow. Though the use of smaller sample volume decreases the pre-concentration factor and increases the limits of detection of 5 out of 17 detected peptides, the recovery, linearity, and reproducibility of the microelution extraction were comparable with cartridge SPE. The effectiveness of protocols was confirmed by analysis of urine samples containing ipamorelin, and GHRP-6 and its metabolites. SPE after urine sample dilution with buffer can be used for faster sample preparation. The use of microelution plates decreases consumption of solvents and allows processing of up to 96 samples simultaneously. Cartridge SPE with manual рН adjustment remains the best option for confirmation. Copyright © 2015 John Wiley & Sons, Ltd. Copyright © 2015 John Wiley & Sons, Ltd.
Stein, A; Shufaro, Y; Hadar, S; Fisch, B; Pinkas, H
2015-03-01
The existing methods for cryopreservation of very low count sperm samples are complex and sub-optimal for individual spermatozoa. Our purpose is to establish an effective simple method for cryoprotecting individual spermatozoa. Samples from patients with OTA were mixed with TYB or HEPES-buffered salt solution with glycerol + glucose and placed on a Cryolock that was plunged directly into liquid nitrogen or exposed to its vapors. Thawing was performed by direct immersion into a drop of warmed medium. The favorable method was tested on diluted samples (10-50 cells) and leftover TESE specimens from patients with azoospermia. Cryopreservation was considered successful if >30 spermatozoa, (>3 motile), or >5 spermatozoa (>1 motile) in diluted and TESE samples, were detected post-thawing. A significantly higher survival rate of seminal spermatozoa was obtained when using the Cryolock with TYB and freezing with liquid nitrogen vapor, compared to HEPES glycerol-glucose (95 vs. 35% respectively). Plunging the Cryolock into liquid nitrogen was detrimental. Cryolock combined with TYB cryoprotection and liquid nitrogen vapor freezing was highly effective for cryopreservation of individual spermatozoa in diluted and TESE samples. The Cryolock may serve for freezing very low-count sperm samples and individual spermatozoa. This method offers simplicity, efficacy, use of available materials, without requiring micromanipulation equipment or skills. © 2015 American Society of Andrology and European Academy of Andrology.
Quantification of isotope-labelled and unlabelled folates in plasma, ileostomy and food samples.
Büttner, Barbara E; Öhrvik, Veronica E; Witthöft, Cornelia M; Rychlik, Michael
2011-01-01
New stable isotope dilution assays were developed for the simultaneous quantitation of [(13)C(5)]-labelled and unlabelled 5-methyltetrahydrofolic acid, 5-formyltetrahydrofolic acid, folic acid along with unlabelled tetrahydrofolic acid and 10-formylfolic acid in clinical samples deriving from human bioavailability studies, i.e. plasma, ileostomy samples, and food. The methods were based on clean-up by strong anion exchange followed by LC-MS/MS detection. Deuterated analogues of the folates were applied as the internal standards in the stable isotope dilution assays. Assay sensitivity was sufficient to detect all relevant folates in the respective samples as their limits of detection were below 0.62 nmol/L in plasma and below 0.73 μg/100 g in food or ileostomy samples. Quantification of the [(13)C(5)]-label in clinical samples offers the possibility to differentiate between folate from endogenous body pools and the administered dose when executing bioavailability trials.
Analysis of peptides using an integrated microchip HPLC-MS/MS system.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kirby, Brian J.; Chirica, Gabriela S.; Reichmuth, David S.
Hyphendated LC-MS techniques are quickly becoming the standard tool for protemic analyses. For large homogeneous samples, bulk processing methods and capillary injection and separation techniques are suitable. However, for analysis of small or heterogeneous samples, techniques that can manipulate picoliter samples without dilution are required or samples will be lost or corrupted; further, static nanospray-type flowrates are required to maximize SNR. Microchip-level integration of sample injection with separation and mass spectrometry allow small-volume analytes to be processed on chip and immediately injected without dilution for analysis. An on-chip HPLC was fabricated using in situ polymerization of both fixed and mobilemore » polymer monoliths. Integration of the chip with a nanospray MS emitter enables identification of peptides by the use of tandem MS. The chip is capable of analyzing of very small sample volumes (< 200 pl) in short times (< 3 min).« less
Reference measurement procedure for total glycerides by isotope dilution GC-MS.
Edwards, Selvin H; Stribling, Shelton L; Pyatt, Susan D; Kimberly, Mary M
2012-04-01
The CDC's Lipid Standardization Program established the chromotropic acid (CA) reference measurement procedure (RMP) as the accuracy base for standardization and metrological traceability for triglyceride testing. The CA RMP has several disadvantages, including lack of ruggedness. It uses obsolete instrumentation and hazardous reagents. To overcome these problems the CDC developed an isotope dilution GC-MS (ID-GC-MS) RMP for total glycerides in serum. We diluted serum samples with Tris-HCl buffer solution and spiked 200-μL aliquots with [(13)C(3)]-glycerol. These samples were incubated and hydrolyzed under basic conditions. The samples were dried, derivatized with acetic anhydride and pyridine, extracted with ethyl acetate, and analyzed by ID-GC-MS. Linearity, imprecision, and accuracy were evaluated by analyzing calibrator solutions, 10 serum pools, and a standard reference material (SRM 1951b). The calibration response was linear for the range of calibrator concentrations examined (0-1.24 mmol/L) with a slope and intercept of 0.717 (95% CI, 0.7123-0.7225) and 0.3122 (95% CI, 0.3096-0.3140), respectively. The limit of detection was 14.8 μmol/L. The mean %CV for the sample set (serum pools and SRM) was 1.2%. The mean %bias from NIST isotope dilution MS values for SRM 1951b was 0.7%. This ID-GC-MS RMP has the specificity and ruggedness to accurately quantify total glycerides in the serum pools used in the CDC's Lipid Standardization Program and demonstrates sufficiently acceptable agreement with the NIST primary RMP for total glyceride measurement.
Schwertfeger, D M; Velicogna, Jessica R; Jesmer, Alexander H; Scroggins, Richard P; Princz, Juliska I
2016-10-18
There is an increasing interest to use single particle-inductively coupled plasma mass spectroscopy (SP-ICPMS) to help quantify exposure to engineered nanoparticles, and their transformation products, released into the environment. Hindering the use of this analytical technique for environmental samples is the presence of high levels of dissolved analyte which impedes resolution of the particle signal from the dissolved. While sample dilution is often necessary to achieve the low analyte concentrations necessary for SP-ICPMS analysis, and to reduce the occurrence of matrix effects on the analyte signal, it is used here to also reduce the dissolved signal relative to the particulate, while maintaining a matrix chemistry that promotes particle stability. We propose a simple, systematic dilution series approach where by the first dilution is used to quantify the dissolved analyte, the second is used to optimize the particle signal, and the third is used as an analytical quality control. Using simple suspensions of well characterized Au and Ag nanoparticles spiked with the dissolved analyte form, as well as suspensions of complex environmental media (i.e., extracts from soils previously contaminated with engineered silver nanoparticles), we show how this dilution series technique improves resolution of the particle signal which in turn improves the accuracy of particle counts, quantification of particulate mass and determination of particle size. The technique proposed here is meant to offer a systematic and reproducible approach to the SP-ICPMS analysis of environmental samples and improve the quality and consistency of data generated from this relatively new analytical tool.
Tailoring magnetic nanoparticle for transformers application.
Morais, P C; Silva, A S; Leite, E S; Garg, V K; Oliveira, A C; Viali, W R; Sartoratto, P P C
2010-02-01
In this study photoacoustic spectroscopy was used to investigate the effect of dilution of an oil-based magnetic fluid sample on the magnetic nanoparticle surface-coating. Changes of the photoacoustic signal intensity on the band-L region (640 to 830 nm) upon dilution of the stock magnetic fluid sample were discussed in terms of molecular surface desorption. The model proposed here assumes that the driving force taking the molecules out from the nanoparticle surface into the bulk solvent is the gradient of osmotic pressure. This gradient of osmotic pressure is established between the nanoparticle surface and the bulk suspension. It is further assumed that the photoacoustic signal intensity (area under the photoacoustic spectra) scales linearly with the number of coating molecules (surface grafting) at the nanoparticle surface. This model picture provides a non-linear analytical description for the reduction of the surface grafting coefficient upon dilution, which was successfully-used to curve-fit the photoacoustic experimental data.
Infinitely dilute partial molar properties of proteins from computer simulation.
Ploetz, Elizabeth A; Smith, Paul E
2014-11-13
A detailed understanding of temperature and pressure effects on an infinitely dilute protein's conformational equilibrium requires knowledge of the corresponding infinitely dilute partial molar properties. Established molecular dynamics methodologies generally have not provided a way to calculate these properties without either a loss of thermodynamic rigor, the introduction of nonunique parameters, or a loss of information about which solute conformations specifically contributed to the output values. Here we implement a simple method that is thermodynamically rigorous and possesses none of the above disadvantages, and we report on the method's feasibility and computational demands. We calculate infinitely dilute partial molar properties for two proteins and attempt to distinguish the thermodynamic differences between a native and a denatured conformation of a designed miniprotein. We conclude that simple ensemble average properties can be calculated with very reasonable amounts of computational power. In contrast, properties corresponding to fluctuating quantities are computationally demanding to calculate precisely, although they can be obtained more easily by following the temperature and/or pressure dependence of the corresponding ensemble averages.
Alcántara-Durán, Jaime; Moreno-González, David; Gilbert-López, Bienvenida; Molina-Díaz, Antonio; García-Reyes, Juan F
2018-04-15
In this work, a sensitive method based on nanoflow liquid chromatography high-resolution mass spectrometry has been developed for the multiresidue determination of veterinary drugs residues in honey, veal muscle, egg and milk. Salting-out supported liquid extraction was employed as sample treatment for milk, veal muscle and egg, while a modified QuEChERS procedure was used in honey. The enhancement of sensitivity provided by the nanoflow LC system also allowed the implementation of high dilution factors as high as 100:1. For all matrices tested, matrix effects were negligible starting from a dilution factor of 100, enabling, thus, the use of external standard calibration instead of matrix-matched calibration of each sample, and the subsequent increase of laboratory throughput. At spiked levels as low as 0.1 or 1 µg kg -1 before the 1:100 dilution, the obtained signals were still significantly higher than the instrumental limit of quantitation (S/N 10). Copyright © 2017 Elsevier Ltd. All rights reserved.
Method to make accurate concentration and isotopic measurements for small gas samples
NASA Astrophysics Data System (ADS)
Palmer, M. R.; Wahl, E.; Cunningham, K. L.
2013-12-01
Carbon isotopic ratio measurements of CO2 and CH4 provide valuable insight into carbon cycle processes. However, many of these studies, like soil gas, soil flux, and water head space experiments, provide very small gas sample volumes, too small for direct measurement by current constant-flow Cavity Ring-Down (CRDS) isotopic analyzers. Previously, we addressed this issue by developing a sample introduction module which enabled the isotopic ratio measurement of 40ml samples or smaller. However, the system, called the Small Sample Isotope Module (SSIM), does dilute the sample during the delivery with inert carrier gas which causes a ~5% reduction in concentration. The isotopic ratio measurements are not affected by this small dilution, but researchers are naturally interested accurate concentration measurements. We present the accuracy and precision of a new method of using this delivery module which we call 'double injection.' Two portions of the 40ml of the sample (20ml each) are introduced to the analyzer, the first injection of which flushes out the diluting gas and the second injection is measured. The accuracy of this new method is demonstrated by comparing the concentration and isotopic ratio measurements for a gas sampled directly and that same gas measured through the SSIM. The data show that the CO2 concentration measurements were the same within instrument precision. The isotopic ratio precision (1σ) of repeated measurements was 0.16 permil for CO2 and 1.15 permil for CH4 at ambient concentrations. This new method provides a significant enhancement in the information provided by small samples.
Dilution as a Model of Long-Term Forgetting
ERIC Educational Resources Information Center
Lansdale, Mark; Baguley, Thom
2008-01-01
This article presents a model of long term forgetting based on 3 ideas: (a) Memory for a stimulus can be described by a population of accessible traces; (b) probability of retrieval after a delay is predicted by the proportion of traces in this population that will be defined as correct if sampled; and (c) this population is diluted over time by…
On-chip dilution in nanoliter droplets.
Thakur, Raviraj; Amin, Ahmed M; Wereley, Steve
2015-09-07
Droplet microfluidics is enabling reactions at nano- and picoliter scale, resulting in faster and cheaper biological and chemical analyses. However, varying concentrations of samples on a drop-to-drop basis is still a challenging task in droplet microfluidics, primarily limited due to lack of control over individual droplets. In this paper, we report an on-chip microfluidic droplet dilution strategy using three-valve peristaltic pumps.
Cole, Laurence A; Khanlian, Sarah A
2004-05-01
False-positive hCG results can lead to erroneous diagnoses and needless chemotherapy and surgery. In the last 2 years, eight publications described cases involving false-positive hCG tests; all eight involved the AxSym test. We investigated the source of this abundance of cases and a simple fix that may be used by clinical laboratories. False-positive hCG was primarily identified by absence of hCG in urine and varying or negative hCG results in alternative tests. Seventeen false-positive serum samples in the AxSym test were evaluated undiluted and at twofold dilution with diluent containing excess goat serum or immunoglobulin. We identified 58 patients with false-positive hCG, 47 of 58 due to the Abbott AxSym total hCGbeta test (81%). Sixteen of 17 of these "false-positive" results (mean 100 mIU/ml) became undetectable when tested again after twofold dilution. A simple twofold dilution with this diluent containing excess goat serum or immunoglobulin completely protected 16 of 17 samples from patients having false-positive results. It is recommended that laboratories using this test use twofold dilution as a minimum to prevent false-positive results.
[Sampling methods for PM2.5 from stationary sources: a review].
Jiang, Jing-Kun; Deng, Jian-Guo; Li, Zhen; Li, Xing-Hua; Duan, Lei; Hao, Ji-Ming
2014-05-01
The new China national ambient air quality standard has been published in 2012 and will be implemented in 2016. To meet the requirements in this new standard, monitoring and controlling PM2,,5 emission from stationary sources are very important. However, so far there is no national standard method on sampling PM2.5 from stationary sources. Different sampling methods for PM2.5 from stationary sources and relevant international standards were reviewed in this study. It includes the methods for PM2.5 sampling in flue gas and the methods for PM2.5 sampling after dilution. Both advantages and disadvantages of these sampling methods were discussed. For environmental management, the method for PM2.5 sampling in flue gas such as impactor and virtual impactor was suggested as a standard to determine filterable PM2.5. To evaluate environmental and health effects of PM2.5 from stationary sources, standard dilution method for sampling of total PM2.5 should be established.
Blacksell, Stuart D.; Tanganuchitcharnchai, Ampai; Jintaworn, Suthatip; Kantipong, Pacharee; Richards, Allen L.; Day, Nicholas P. J.
2016-01-01
The enzyme-linked immunosorbent assay (ELISA) has been proposed as an alternative serologic diagnostic test to the indirect immunofluorescence assay (IFA) for scrub typhus. Here, we systematically determine the optimal sample dilution and cutoff optical density (OD) and estimate the accuracy of IgM ELISA using Bayesian latent class models (LCMs). Data from 135 patients with undifferentiated fever were reevaluated using Bayesian LCMs. Every patient was evaluated for the presence of an eschar and tested with a blood culture for Orientia tsutsugamushi, three different PCR assays, and an IgM IFA. The IgM ELISA was performed for every sample at sample dilutions from 1:100 to 1:102,400 using crude whole-cell antigens of the Karp, Kato, and Gilliam strains of O. tsutsugamushi developed by the Naval Medical Research Center. We used Bayesian LCMs to generate unbiased receiver operating characteristic curves and found that the sample dilution of 1:400 was optimal for the IgM ELISA. With the optimal cutoff OD of 1.474 at a sample dilution of 1:400, the IgM ELISA had a sensitivity of 85.7% (95% credible interval [CrI], 77.4% to 86.7%) and a specificity of 98.1% (95% CrI, 97.2% to 100%) using paired samples. For the ELISA, the OD could be determined objectively and quickly, in contrast to the reading of IFA slides, which was both subjective and labor-intensive. The IgM ELISA for scrub typhus has high diagnostic accuracy and is less subjective than the IgM IFA. We suggest that the IgM ELISA may be used as an alternative reference test to the IgM IFA for the serological diagnosis of scrub typhus. PMID:27008880
Takakura, Yukiko; Osanai, Hiroki; Masuzawa, Takuya; Wakabayashi, Hidehiko; Nishimura, Toshihide
2014-01-01
The aroma extract dilution analysis of an extract prepared from pork stock and subsequent experiments led to the identification of 15 aroma-active compounds in the flavor dilution factor range of 64-2048. Omission experiments to select the most aroma-active compounds from the 15 odor compounds suggested acetol, octanoic acid, δ-decalactone, and decanoic acid as the main active compounds contributing to the aroma of pork stock. Aroma recombination, addition, and omission experiments of these four aroma compounds in taste-reconstituted pork stock showed that each compound had an individual aroma profile. A comparison of the overall aroma between this recombined mixture and pork stock showed strong similarity, suggesting that the key aroma compounds had been successfully identified.
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2010 CFR
2010-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2011 CFR
2011-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
40 CFR 91.420 - CVS concept of exhaust gas sampling system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... that complete mixing of the engine exhaust and background air is assured prior to the sampling probe.... The background probe must draw a representative sample of the background air during each sampling mode...) sampling system. If a critical flow venturi (CFV) is used on the dilute exhaust sample probe, this system...
Raut, Ashlesha S; Kalonia, Devendra S
2015-04-01
Opalescence indicates physical instability of a formulation because of the presence of aggregates or liquid-liquid phase separation in solution and has been reported for monoclonal antibody (mAb) formulations. Increased solution opalescence can be attributed to attractive protein-protein interactions (PPIs). Techniques including light scattering, AUC, or membrane osmometry are routinely employed to measure PPIs in dilute solutions, whereas opalescence is seen at relatively higher concentrations, where both long- and short-range forces contribute to overall PPIs. The mAb molecule studied here shows a unique property of high opalescence because of liquid-liquid phase separation. In this study, opalescence measurements are correlated to PPIs measured in diluted and concentrated solutions using light scattering (kD ) and high-frequency rheology (G'), respectively. Charges on the molecules were calculated using zeta potential measurements. Results indicate that high opalescence and phase separation are a result of the attractive interactions in solution; however, the presence of attractive interactions do not always imply phase separation. Temperature dependence of opalescence suggests that thermodynamic contribution to opalescence is significant and Tcloud can be utilized as a potential tool to assess attractive interactions in solution. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.
Farrell, P B; Foote, R H; McArdle, M M; Trouern-Trend, V L; Tardif, A L
1996-01-01
Proper handling of semen prior to computer-assisted sperm analysis (CASA) is critical if the analysis is to be representative of the fresh sample. The effects of diluting medium or dilution and holding time before CASA on multiple sperm characteristics were studied. Four replicates of unselected semen samples from each of eight human donors were diluted with phosphate-buffered saline (PBS)-glucose plus bovine serum albumin (BSA), with Tyrode's albumen lactate pyruvate (TALP), and with high-potassium TALP (K-TALP) to a concentration of approximately 25 x 10(6) sperm/ml. The diluted semen was held for 0, 1, and 2 hours at approximately 30 degrees C before CASA, with little difference between the three diluents in all 12 variables measured. There was a decline of 3-6% in the proportion of motile sperm over a 2-hour period (P < 0.05). Donors were the largest source of differences (P < 0.05). Rabbit sperm (five bucks, four ejaculates per buck) were processed in a manner similar to that of the human sperm. There was a major effect of media. The average percentages of motile sperm over 2 hours in TALP, K-TALP, and PBS were 76, 42, and 29%, respectively (P < 0.05), with a decline of only 3% in TALP during the 2 hours. Hyperactivity and other characteristics were affected by treatment. Donors were a large source of variation. Bull semen (10 bulls, two ejaculates per bull) either was not diluted or diluted with TALP 2x or 4x and held for 0, 1, and 2 hours at 30 degrees C. It was then diluted to 25 x 10(6) sperm/ml with TALP. There was little change in most sperm characteristics in any treatment during the first hour, although many of the changes were statistically significant. The percentage of motile sperm in undiluted semen declined from 87% to 82% over 2 hours. Modified TALP was a suitable medium for sperm from all three species, and a simple PBS-glucose-BSA medium can be used for human sperm.
Kiess, A S; Parker, H M; McDaniel, C D
2010-08-01
Poultry is a major reservoir for Campylobacter, the leading cause of foodborne illness in the United States, but how broilers become initially colonized is still under debate. Broiler litter is a potential source, but the best technique for quantifying Campylobacter from litter is still unknown. Therefore, our objectives were to determine if certain media are more selective for quantifying Campylobacter and if enrichment allows for the detection of stressed or viable but nonculturable cells from broiler litter samples. In this trial, 5 media and 2 culturing techniques were used to enumerate Campylobacter from broiler litter. The media used were campy-Line agar (CLA), campy-cefex agar (CCA), modified CCA, Campylobacter agar plates (CAP), and modified charcoal cefoperazone deoxycholate agar. Litter samples were obtained from a commercial broiler house. Each sample was equally divided and diluted 10-fold into peptone, for direct plating, or 4-fold into Campylobacter enrichment broth. Samples diluted in peptone were direct-plated onto each media and incubated under microaerophilic conditions for 48 h at 42 degrees C. Samples diluted in enrichment broth were incubated under the same conditions for 24 h, then further diluted to 10-fold before plating. Plates from enriched samples were incubated for an additional 24 h after plating. After incubation, all plates (direct and enriched) were counted and presumptive positive colonies were confirmed using a Campylobacter latex agglutination kit. Results indicated that there was no difference in the ability of any of the selective media tested to grow Campylobacter. Direct-plated samples had a higher Campylobacter isolation rate compared with enriched samples. The CLA and CAP were able to suppress total bacterial growth better than modified charcoal cefoperazone deoxycholate, modified CCA, and CCA. The CLA and CAP were the only media able to detect total bacterial population shifts over time. In conclusion, it is important before making a final decision on a selective medium to consider the medium's ability to suppress total bacterial growth as well as isolate Campylobacter.
Jin, Rong; Liu, Guorui; Zheng, Minghui; Fiedler, Heidelore; Jiang, Xiaoxu; Yang, Lili; Wu, Xiaolin; Xu, Yang
2017-08-04
Isotopic dilution gas chromatography combined with high resolution mass spectrometry (GC/HRMS) has overwhelming advantages with respect to the accuracy of congener-specific ultratrace analysis of complex persistent organic pollutants (POPs) in environmental matrices. However, an isotopic dilution GC/HRMS method for analysis of chlorinated and brominated polycyclic aromatic hydrocarbons (Cl-PAHs and Br-PAHs) using 13 C-labelled congeners as internal standards has not been established. In this study, a method for identification and quantification of 38 congeners of Cl-PAHs and Br-PAHs in atmosphere and stack gas samples from waste incinerators was developed using the isotopic dilution GC/HRMS technique. The instrumental detection limits of the GC/HRMS method ranged from 0.2pg to 1.8pg for Cl-PAH congeners, and 0.7pg to 2.7pg for Br-PAH congeners, which were about three orders of magnitude lower than those of the GC/quadrupole MS method. This new method developed was also the first to enable determination of Cl-PAH and Br-PAH homologs comprising congeners with the same molecular skeleton and chlorine or bromine substitution numbers. Among the detected congeners, seven Cl-PAH congeners and thirteen Br-PAH congeners that were abundant in the atmosphere and stack gases released from waste incinerators were firstly detected in real samples and reported using the established isotopic dilution GC/HRMS method. The developed isotopic dilution GC/HRMS is significant and needed for better studying the environmental behavior and health risk of Cl-PAHs and Br-PAHs. Copyright © 2017 Elsevier B.V. All rights reserved.
40 CFR 1066.135 - Linearity verification.
Code of Federal Regulations, 2014 CFR
2014-07-01
... CVS, double-dilution, and partial-flow systems. (3) PM sample. (4) Chiller sample, for gaseous sampling systems that use thermal chillers to dry samples, and that use chiller temperature to calculate dewpoint at the chiller outlet. For testing, if you choose to use the high alarm temperature setpoint for...
40 CFR 1065.805 - Sampling system.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 40 Protection of Environment 33 2014-07-01 2014-07-01 false Sampling system. 1065.805 Section 1065.805 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... background samples for correcting dilution air for background concentrations of alcohols and carbonyls. (c...
40 CFR 1065.805 - Sampling system.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 40 Protection of Environment 34 2012-07-01 2012-07-01 false Sampling system. 1065.805 Section 1065.805 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... background samples for correcting dilution air for background concentrations of alcohols and carbonyls. (c...
40 CFR 1065.805 - Sampling system.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 40 Protection of Environment 34 2013-07-01 2013-07-01 false Sampling system. 1065.805 Section 1065.805 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR POLLUTION CONTROLS... background samples for correcting dilution air for background concentrations of alcohols and carbonyls. (c...
Effect of dilution temperature on boar semen quality.
López Rodríguez, A; Rijsselaere, T; Vyt, P; Van Soom, A; Maes, D
2012-10-01
As boar semen is very sensitive to cold shock and changes in temperature during semen processing can have a profound impact on semen quality, the effect of the extender temperature at the time of dilution was investigated in a two-step dilution protocol for boar semen being processed for liquid storage. Fifteen boars of different breeds and ages from a commercial artificial insemination centre were included. One ejaculate per boar was collected and processed with Beltsville Thawing Solution semen extender. Each ejaculate was diluted (1 : 1) at 30 °C, and subsequently, the samples were diluted (30 × 10(6) sperm/ml) with either preheated extender [29.3 °C ± 0.2 °C, group A (GA)] or extender at room temperature [22.7 °C ± 0.6 °C, group B (GB)]. Samples were transported to the Faculty of Veterinary Medicine (University of Ghent, Belgium) in two isotherm boxes (one per group), stored at 17 °C and investigated for three consecutive days (D0 to D2). At D0, D1 and D2, motility parameters [computer-assisted semen analysis (CASA)] and the per cent of sperm with intact membrane (% IM) by eosin nigrosin staining were evaluated. At D0 and D2, the % of sperm with intact acrosome (% IA) was studied by Pisum sativum agglutinin staining. The average temperature of the 1 : 1 dilution was 29.4 °C ± 1.1 °C immediately after extender addition. No significant differences were found between groups for per cent motility [79.3 ± 9.0 for GA and 81.1 ± 9.2 for GB (p = 0.372)], % progressive motility [56.5 ± 13.3 for GA and 58.4 ± 13.8 for GB (p = 0.737)] or any CASA parameter. No differences were found for % IM [85.1 ± 10.7 and 84.5 ± 3.8 for GA and GB, respectively (p = 0.761)] and % IA [72.2 ± 9.4 for GA and 68.3 ± 16.6 for GB (p = 0.792)]. In conclusion, when a two-step dilution is performed, preheating the extender for the second dilution to match the semen temperature did not result in better semen quality compared to a dilution at a moderate room temperature. © 2011 Blackwell Verlag GmbH.
NASA Astrophysics Data System (ADS)
McFarlane Holman, Karen L.; Latimer, Matthew J.; Yachandra, Vittal K.
2004-06-01
X-ray absorption spectroscopy (XAS) in the intermediate x-ray region (2-6 keV) for dilute biological samples has been limited because of detector/flux limitations and inadequate cryogenic instrumentation. We have designed and constructed a new tailpiece/sample chamber for a commercially available liquid helium cooled cryostat which overcomes difficulties related to low fluorescence signals by using thin window materials and incorporating an internal photodiode detector. With the apparatus, XAS data at the Cl, S, and Ca K edges have been collected on frozen solutions and biological samples at temperatures down to 60 K. A separate chamber has been incorporated for collecting room-temperature spectra of standard compounds (for energy calibration purposes) which prevents contamination of the cryostat chamber and allows the sample to remain undisturbed, both important concerns for studying dilute and radiation-sensitive samples.
Jia, Xiujuan; Wang, Tiebang; Bu, Xiaodong; Tu, Qiang; Spencer, Sandra
2006-04-11
A graphite furnace atomic absorption (GFAA) spectrometric method for the determination of ruthenium (Rh) in solid and liquid pharmaceutical compounds has been developed. Samples are dissolved or diluted in dimethyl sulfoxide (DMSO) without any other treatment before they were analyzed by GFAA with a carefully designed heating program to avoid pre-atomization signal loss and to achieve suitable sensitivity. Various inorganic and organic solvents were tested and compared and DMSO was found to be the most suitable. In addition, ruthenium was found to be stable in DMSO for at least 5 days. Spike recoveries ranged from 81 to 100% and the limit of quantitation (LOQ) was determined to be 0.5 microg g(-1) for solid samples or 0.005 microg ml(-1) for liquid samples based a 100-fold dilution. The same set of samples was also analyzed by ICP-MS with a different sample preparation method, and excellent agreement was achieved.
Dispersion of Sound in Dilute Suspensions with Nonlinear Particle Relaxation
NASA Technical Reports Server (NTRS)
Kandula, Max
2010-01-01
The theory accounting for nonlinear particle relaxation (viscous and thermal) has been applied to the prediction of dispersion of sound in dilute suspensions. The results suggest that significant deviations exist for sound dispersion between the linear and nonlinear theories at large values of Omega(Tau)(sub d), where Omega is the circular frequency, and Tau(sub d) is the Stokesian particle relaxation time. It is revealed that the nonlinear effect on the dispersion coefficient due to viscous contribution is larger relative to that of thermal conduction
Low probability of a dilution effect for Lyme borreliosis in Belgian forests.
Ruyts, Sanne C; Landuyt, Dries; Ampoorter, Evy; Heylen, Dieter; Ehrmann, Steffen; Coipan, Elena C; Matthysen, Erik; Sprong, Hein; Verheyen, Kris
2018-04-22
An increasing number of studies have investigated the consequences of biodiversity loss for the occurrence of vector-borne diseases such as Lyme borreliosis, the most common tick-borne disease in the northern hemisphere. As host species differ in their ability to transmit the Lyme borreliosis bacteria Borrelia burgdorferi s.l. to ticks, increased host diversity can decrease disease prevalence by increasing the proportion of dilution hosts, host species that transmit pathogens less efficiently. Previous research shows that Lyme borreliosis risk differs between forest types and suggests that a higher diversity of host species might dilute the contribution of small rodents to infect ticks with B. afzelii, a common Borrelia genospecies. However, empirical evidence for a dilution effect in Europe is largely lacking. We tested the dilution effect hypothesis in 19 Belgian forest stands of different forest types along a diversity gradient. We used empirical data and a Bayesian belief network to investigate the impact of the proportion of dilution hosts on the density of ticks infected with B. afzelii, and identified the key drivers determining the density of infected ticks, which is a measure of human infection risk. Densities of ticks and B. afzelii infection prevalence differed between forest types, but the model indicated that the density of infected ticks is hardly affected by dilution. The most important variables explaining variability in disease risk were related to the density of ticks. Combining empirical data with a model-based approach supported decision making to reduce tick-borne disease risk. We found a low probability of a dilution effect for Lyme borreliosis in a north-western European context. We emphasize that under these circumstances, Lyme borreliosis prevention should rather aim at reducing tick-human contact rate instead of attempting to increase the proportion of dilution hosts. Copyright © 2018. Published by Elsevier GmbH.
Quality assured measurements of animal building emissions: odor concentrations.
Jacobson, Larry D; Hetchler, Brian P; Schmidt, David R; Nicolai, Richard E; Heber, Albert J; Ni, Ji-Qin; Hoff, Steven J; Koziel, Jacek A; Zhang, Yuanhui; Beasley, David B; Parker, David B
2008-06-01
Standard protocols for sampling and measuring odor emissions from livestock buildings are needed to guide scientists, consultants, regulators, and policy-makers. A federally funded, multistate project has conducted field studies in six states to measure emissions of odor, coarse particulate matter (PM(10)), total suspended particulates, hydrogen sulfide, ammonia, and carbon dioxide from swine and poultry production buildings. The focus of this paper is on the intermittent measurement of odor concentrations at nearly identical pairs of buildings in each state and on protocols to minimize variations in these measurements. Air was collected from pig and poultry barns in small (10 L) Tedlar bags through a gas sampling system located in an instrument trailer housing gas and dust analyzers. The samples were analyzed within 30 hr by a dynamic dilution forced-choice olfactometer (a dilution apparatus). The olfactometers (AC'SCENT International Olfactometer, St. Croix Sensory, Inc.) used by all participating laboratories meet the olfactometry standards (American Society for Testing and Materials and European Committee for Standardization [CEN]) in the United States and Europe. Trained panelists (four to eight) at each laboratory measured odor concentrations (dilution to thresholds [DT]) from the bag samples. Odor emissions were calculated by multiplying odor concentration differences between inlet and outlet air by standardized (20 degrees C and 1 atm) building airflow rates.
Staebler-Wronski Effect Studied with Positrons
NASA Astrophysics Data System (ADS)
Gessmann, Thomas; Weber, Marc H.; Lynn, Kelvin G.; Crandall, Richard S.; Yang, Jeffrey; Guha, Subhendu
2001-03-01
Positrons implanted into condensed matter may localize in open volume defects. The energies of gamma-rays emitted after annihilation of positrons with electrons are Doppler-shifted corresponding to the electron momenta at the annihilation site. We used depth-dependent positron annihilation spectroscopy [1] to investigate layers of hydrogenated amorphous-silicon (a-Si:H) deposited by plasma-enhanced chemical-vapor deposition (PECVD). The positron data are interpreted in terms of a dimensionless S-parameter referred to crystalline silicon. The magnitude of S is a measure for the size and concentration of open volume defects acting as trapping sites for positrons. In samples subjected to different hydrogen dilutions during film growth the S-parameter indicates a transition from the amorphous to the microcrystalline structure for large hydrogen-to-disilane ratios. In layers (thickness 250 nm) grown on stainless steel substrates [2] we find that hydrogen dilution results in reduced S-values (1.0127+-0.0007) compared to non-hydrogen diluted samples (1.0316+-0.0007) at room temperature. The S parameters in both hydrogen diluted and non-hydrogen diluted are the lowest ever measured attesting to the dense nature of the material. Previous studies [2] showed superior solar cell characteristics of these layers when grown with hydrogen-to-disilane ratios near the onset of microcrystallinity. Following one-sun light exposure for 400 hr a further decrease in S is observed in both normal and hydrogen diluted samples suggesting a change in the defect associated with light soaking. Two hours annealing at 160 C in air restores the original S-parameter. This behavior was observed for the first time by positron annihilation spectroscopy and may be interpreted as evidence of large scale metastable changes associated with the Staebler-Wronski effect [3]. [1] P.J. Schultz and K.G. Lynn, Rev. Mod. Phys. 60, 701 (1988). [2] S. Guha, J. Yang, D. L. Williamson, Y. Lubianker, J. D. Cohen, A. H. Mahan Appl. Phys. Lett. 74, 1860 (1999). [3] D.L. Staebler and C.R. Wronski, Appl. Phys. Lett. 31, 292 (1977).
Montei, Carolyn; McDougal, Susan; Mozola, Mark; Rice, Jennifer
2014-01-01
The Soleris Non-fermenting Total Viable Count method was previously validated for a wide variety of food products, including cocoa powder. A matrix extension study was conducted to validate the method for use with cocoa butter and cocoa liquor. Test samples included naturally contaminated cocoa liquor and cocoa butter inoculated with natural microbial flora derived from cocoa liquor. A probability of detection statistical model was used to compare Soleris results at multiple test thresholds (dilutions) with aerobic plate counts determined using the AOAC Official Method 966.23 dilution plating method. Results of the two methods were not statistically different at any dilution level in any of the three trials conducted. The Soleris method offers the advantage of results within 24 h, compared to the 48 h required by standard dilution plating methods.
Byrem, T M; Bartlett, P C; Donohue, H; Voisinet, B D; Houseman, J T
2012-11-23
Control of Neospora caninum infection in cattle depends on specific, ante-mortem detection of infected animals and limiting their use as breeding stock or by culling. The objective of the present study was to determine appropriate cut-off values and diagnostic performance of a milk ELISA test using whole and skim milk in a commercial serum ELISA test (IDEXX Neospora Ab). Serum and milk samples were obtained from a total of 475 lactating cows from two herds with and two herds without a previous history of N. caninum-associated abortion. Overall seroprevalence determined by the ELISA was 18.3%. Compared to serum ELISA values, correlation and overall performance assessed by receiver operating characteristic analysis was higher when either whole or skim milk samples were diluted 1:2 compared to undiluted or 1:5 diluted samples. Diagnostic performance for analysis of whole and skim milk was compared at cut-off values that achieved a desired operating characteristic of at least 95% specificity. For whole milk diluted 1:2 and a cut-off of 0.14 (S/P ratio), sensitivity and kappa values were 74.7% (95% CI 64.3-83.4) and 0.70 (95% CI 0.61-0.78), respectively. For skim milk diluted 1:2 and a cut-off of 0.30, sensitivity and kappa values were 77.0% (95% CI 66.8-85.4) and 0.72 (95% CI 0.64-0.80), respectively. Using the selected cut-offs, the IDEXX Neospora Ab Test is equally suited for the analysis of whole and skim milk as a screening tool in neosporosis control programs. Copyright © 2012 Elsevier B.V. All rights reserved.
Sampling and physical characterization of diesel exhaust aerosols. SAE Paper 770720
DOE Office of Scientific and Technical Information (OSTI.GOV)
Verrant, J.A.; Kittelson, D.A.
Diesel exhaust aerosols are highly dynamic and therefore, difficult to sample without introducing falsification. This paper describes a study of these aerosols using a rapid dilution sampling system and an electrical aerosol analyzer. An Onan single cylinder indirect injection engine was used as an exhaust source. The sampler diluted the exhaust with clean air in ratios of 400:1 to 600:1 in order to prevent sample falsification by condensation and coagulation. The electrical aerosol analyzer was used to determine particle size and concentration. Volume concentration in the exhaust ranged from 2000 to 50,000 ..mu.. m/sup 3/ cm/sup -3/ which correspond tomore » mass loadings of 2.0 to 50 mg m/sup -3/ (assuming a density of 1 gm cm/sup -3/). Volume geometric mean diameters ranged from 0.12 to 0.19 ..mu..m. Evaporation and coagulation effects on diesel aerosols were observed by aging in a Teflon holding bag. A simple evaporation model was fit to the decrease of aerosol volume concentration with time. The fit revealed that the aerosols evaporated as if they were composed of normal paraffins in the 350 to 500 molecular weight range. Although the sample dilution system used in this study may alter the sample somewhat, it is probably analogous to what happens at the tailpipe of a vehicle. Measurements taken on a test track in the exhaust plume of a Peugeot 504 diesel showed aerosol size distributions very similar to those measured in our laboratory studies.« less
Bigalke, Hans; Rummel, Andreas
2015-11-25
The historical method for the detection of botulinum neurotoxin (BoNT) is represented by the mouse bioassay (MBA) measuring the animal survival rate. Since the endpoint of the MBA is the death of the mice due to paralysis of the respiratory muscle, an ex vivo animal replacement method, called mouse phrenic nerve (MPN) assay, employs the isolated N. phrenicus-hemidiaphragm tissue. Here, BoNT causes a dose-dependent characteristic decrease of the contraction amplitude of the indirectly stimulated muscle. Within the EQuATox BoNT proficiency 13 test samples were analysed using the MPN assay by serial dilution to a bath concentration resulting in a paralysis time within the range of calibration curves generated with BoNT/A, B and E standards, respectively. For serotype identification the diluted samples were pre-incubated with polyclonal anti-BoNT/A, B or E antitoxin or a combination of each. All 13 samples were qualitatively correctly identified thereby delivering superior results compared to single in vitro methods like LFA, ELISA and LC-MS/MS. Having characterized the BoNT serotype, the final bath concentrations were calculated using the calibration curves and then multiplied by the respective dilution factor to obtain the sample concentration. Depending on the source of the BoNT standards used, the quantitation of ten BoNT/A containing samples delivered a mean z-score of 7 and of three BoNT/B or BoNT/E containing samples z-scores <2, respectively.
Sampling Error in a Particulate Mixture: An Analytical Chemistry Experiment.
ERIC Educational Resources Information Center
Kratochvil, Byron
1980-01-01
Presents an undergraduate experiment demonstrating sampling error. Selected as the sampling system is a mixture of potassium hydrogen phthalate and sucrose; using a self-zeroing, automatically refillable buret to minimize titration time of multiple samples and employing a dilute back-titrant to obtain high end-point precision. (CS)
Oxalate content of different drinkable dilutions of tea infusions after different brewing times.
Lotfi Yagin, Neda; Mahdavi, Reza; Nikniaz, Zeinab
2012-01-01
The aims of this study were to determine the effect of different brewing times and diluting on oxalate content of loose-packed black teas consumed in Tabriz, Iran. The oxalate content of black teas after brewing for 5, 10, 15, 30, 60 minutes was measured in triplicate by enzymatic assay. In order to attain the most acceptable dilution of tea infusions, tea samples which were brewed for 15, 30 and 60 minutes were diluted two (120 ml), three (80 ml) and four (60 ml) times respectively. There was a stepwise increase in oxalate concentrations associated with increased brewing times (P< 0.001) with oxalate contents ranging from 4.4 mg/240 ml for the 5 min to 6.3 mg/240 ml for 60 min brewing times, respectively. There were significant differences between the mean oxalate content of different dilutions after brewing for 15, 30 and 60 minutes (P< 0.001). The oxalate content of Iranian consumed black tea after different brewing times and different dilution was below the recommended levels. Therefore, it seems that consumption of black tea several times per day would not pose significant health risk in kidney stone patients and susceptible individuals.
Oxalate Content of Different Drinkable Dilutions of Tea Infusions after Different Brewing Times
Lotfi Yagin, Neda; Mahdavi, Reza; Nikniaz, Zeinab
2012-01-01
Background: The aims of this study were to determine the effect of different brewing times and diluting on oxalate content of loose-packed black teas consumed in Tabriz, Iran. Methods: The oxalate content of black teas after brewing for 5, 10, 15, 30, 60 minutes was measured in triplicate by enzymatic assay. In order to attain the most acceptable dilution of tea infusions, tea samples which were brewed for 15, 30 and 60 minutes were diluted two (120 ml), three (80 ml) and four (60 ml) times respectively. Results: There was a stepwise increase in oxalate concentrations associated with increased brewing times (P< 0.001) with oxalate contents ranging from 4.4 mg/240 ml for the 5 min to 6.3 mg/240 ml for 60 min brewing times, respectively. There were significant differences between the mean oxalate content of different dilutions after brewing for 15, 30 and 60 minutes (P< 0.001). Conclusion: The oxalate content of Iranian consumed black tea after different brewing times and different dilution was below the recommended levels. Therefore, it seems that consumption of black tea several times per day would not pose significant health risk in kidney stone patients and susceptible individuals. PMID:24688937
Doing More with Less? Toward Increasing the Resolution of Protistan Grazing-rate Measurements.
NASA Astrophysics Data System (ADS)
Morison, F.; Menden-Deuer, S.
2016-02-01
The dilution method is the standard protocol to quantify phytoplankton grazing-mortality rates and has been key in developing an understanding of protistan grazing impact on ocean primary production. Although the method's extensive use has facilitated the acquisition of a global dataset, its laborious application hinders the sampling resolution needed to fill knowledge gaps remaining at the geographical, seasonal, and vertical scales, and of the effects of climate-related factors influencing grazing magnitude. Here we present a rigorous assessment of an abbreviated method known as the 2-point. We analyzed unpublished results from 77 dilution experiments performed using a series of up to 5 dilutions under a wide range of chlorophyll concentrations and temperatures. We quantified the difference between estimates of both phytoplankton growth and grazing-mortality obtained based on the full dilution series and those obtained when the number of dilutions was reduced to 2. We considered the effect of non-linearity and chlorophyll concentration, and generated quantified estimates of trade-offs when choosing the fraction of seawater in the diluted treatment. Ultimately, we provide an assessment of the reliability of the 2-point method and recommendations on how to apply it.
NASA Astrophysics Data System (ADS)
Larsen, D.; Paul, J.
2017-12-01
Groundwater salinization is occurring in the Mississippi River Valley Alluvial (MRVA) aquifer in southeastern Arkansas (SE AR). Water samples from the MRVA aquifer in Chicot and Desha counties have yielded elevated Cl-concentrations with some as high as 1,639 mg/L. Considering that the MRVA aquifer is the principle source of irrigation water for the agricultural economy of SE AR, salinization needs to be addressed to ensure the sustainability of crop, groundwater, and soil resources in the area. The origin of elevated salinity in MRVA aquifer was investigated using spatial and factor analysis of historical water quality data, and sampling and tracer analysis of groundwater from irrigation, municipal, and flowing industrial wells in SE AR. Spatial analysis of Cl- data in relation to soil type, geomorphic features and sand-blow density indicate that the Cl- anomalies are more closely related to the sand-blow density than soil data, suggesting an underlying tectonic control for the distribution of salinity. Factor analysis of historical geochemical data from the MRVA and underlying Sparta aquifer shows dilute and saline groups, with saline groups weighted positively with Cl- or Na+ and Cl-. Tracer data suggest a component of evaporatively evolved crustal water of pre-modern age has mixed with younger, fresher meteoric sources in SE AR to create the saline conditions in the MRVA aquifer. Stable hydrogen and oxygen values of waters sampled from the Tertiary Sparta and MRVA aquifers deviate from the global and local meteoric water lines along an evaporative trend (slope=4.4) and mixing line with Eocene Wilcox Group groundwaters. Ca2+ and Cl- contents vary with Br- along mixing trends between dilute MRVA water and Jurassic Smackover Formation pore fluids in southern AR. Increasing Cl- content with C-14 age in MRVA aquifer groundwater suggests that the older waters are more saline. Helium isotope ratios decrease with He gas content for more saline water, consistent with crustal He production. Our model for the system invokes upward migration of Smackover pore fluids and other deep groundwater along faults in SE AR, whereby the saline fluids intrude and mix with dilute water in the MRVA aquifer to create saline conditions. Other processes, such as infiltration of saline irrigation runoff, may also be contributing to the problem.
40 CFR 89.419 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2010 CFR
2010-07-01
...) Continuous HC measurement system. (i) The continuous HC sample system (as shown in Figure 2 or 3 in appendix... this is not required. (ii) No other analyzers may draw a sample from the continuous HC sample probe... continuous HC sampling system shall consist of a probe (which must raise the sample to the specified...
NASA Astrophysics Data System (ADS)
Li, Wenlong; Cheng, Zhiwei; Wang, Yuefei; Qu, Haibin
2013-01-01
In this paper we describe the strategy used in the development and validation of a near infrared spectroscopy method for the rapid determination of baicalin, chlorogenic acid, ursodeoxycholic acid (UDCA), chenodeoxycholic acid (CDCA), and the total solid contents (TSCs) in the Tanreqing injection. To increase the representativeness of calibration sample set, a concentrating-diluting method was adopted to artificially prepare samples. Partial least square regression (PLSR) was used to establish calibration models, with which the five quality indicators can be determined with satisfied accuracy and repeatability. In addition, the slope/bias (S/B) method was used for the models transfer between two different types of NIR instruments from the same manufacturer, which is contributing to enlarge the application range of the established models. With the presented method, a great deal of time, effort and money can be saved when large amounts of Tanreqing injection samples need to be analyzed in a relatively short period of time, which is of great significance to the traditional Chinese medicine (TCM) industries.
Impurity quadrupole Kondo ground state in a dilute Pr system Y1-xPrxIr2Zn20
NASA Astrophysics Data System (ADS)
Yamane, Yu; Onimaru, Takahiro; Uenishi, Kazuto; Wakiya, Kazuhei; Matsumoto, Keisuke T.; Umeo, Kazunori; Takabatake, Toshiro
2018-05-01
The electrical resistivity ρ and specific heat C of a dilute Pr system Y1-xPrxIr2Zn20 for 0 ≤ x ≤ 0.44 were measured to study the phenomena arising from active quadrupoles of the Pr3+ ion with 4f2 configuration. On cooling, ρ's of all samples monotonically decrease, while the residual resistivity ratio ρ(300 K)/ρ(3 K) drastically decreases with x. In the whole range x ≤ 0.44, the magnetic contribution to the specific heat divided by temperature Cm/T shows a broad maximum at around 10 K, which can be reproduced by a two-level model with a first-excited triplet separated by 30 K from a ground state doublet. This indicates that the crystalline electric field ground state of the Pr ions remains in the Γ3 doublet for the cubic Td point group. On cooling, the Cm/T data for x = 0.085 and 0.44 approach constant values at T<0.3 K as expected from the random two-level model. By contrast, Cm/T for x = 0.044 increases continuously down to 0.08 K, suggesting a non-Fermi liquid state due to the impurity quadrupole Kondo effect.
Vang, Óluva K; Corfitzen, Charlotte B; Smith, Christian; Albrechtsen, Hans-Jørgen
2014-11-01
Fast and reliable methods are required for monitoring of microbial drinking water quality in order to protect public health. Adenosine triphosphate (ATP) was investigated as a potential real-time parameter for detecting microbial ingress in drinking water contaminated with wastewater or surface water. To investigate the ability of the ATP assay in detecting different contamination types, the contaminant was diluted with non-chlorinated drinking water. Wastewater, diluted at 10(4) in drinking water, was detected with the ATP assay, as well as 10(2) to 10(3) times diluted surface water. To improve the performance of the ATP assay in detecting microbial ingress in drinking water, different approaches were investigated, i.e. quantifying microbial ATP or applying reagents of different sensitivities to reduce measurement variations; however, none of these approaches contributed significantly in this respect. Compared to traditional microbiological methods, the ATP assay could detect wastewater and surface water in drinking water to a higher degree than total direct counts (TDCs), while both heterotrophic plate counts (HPC 22 °C and HPC 37 °C) and Colilert-18 (Escherichia coli and coliforms) were more sensitive than the ATP measurements, though with much longer response times. Continuous sampling combined with ATP measurements displays definite monitoring potential for microbial drinking water quality, since microbial ingress in drinking water can be detected in real-time with ATP measurements. The ability of the ATP assay to detect microbial ingress is influenced by both the ATP load from the contaminant itself and the ATP concentration in the specific drinking water. Consequently, a low ATP concentration of the specific drinking water facilitates a better detection of a potential contamination of the water supply with the ATP assay. Copyright © 2014 Elsevier Ltd. All rights reserved.
Diagnostic efficacy of cell block method for vitreoretinal lymphoma.
Kase, Satoru; Namba, Kenichi; Iwata, Daiju; Mizuuchi, Kazuomi; Kitaichi, Nobuyoshi; Tagawa, Yoshiaki; Okada-Kanno, Hiromi; Matsuno, Yoshihiro; Ishida, Susumu
2016-03-17
Vitreoretinal lymphoma (VRL) is a life- and sight-threatening disorder. The aim of this study was to analyze the usefulness of the cell block method for diagnosis of VRL. Sixteen eyes in 12 patients with VRL, and 4 eyes in 4 patients with idiopathic uveitis presenting with vitreous opacity were enrolled in this study. Both undiluted vitreous and diluted fluids were isolated during micro-incision vitrectomy. Cell block specimens were prepared in 19 eyes from diluted fluid containing shredding vitreous. These specimens were then submitted for HE staining as well as immunocytological analyses with antibodies against the B-cell marker CD20, the T-cell marker CD3, and cell proliferation marker Ki67. Conventional smear cytology was applied in 14 eyes with VRL using undiluted vitreous samples. The diagnosis of VRL was made based on the results of cytology, concentrations of interleukin (IL)-10 and IL-6 in undiluted vitreous, and immunoglobulin heavy chain gene rearrangement analysis. Atypical lymphoid cells were identified in 14 out of 15 cell block specimens of VRL (positive rate: 93.3 %), but in 5 out of 14 eyes in conventional smear cytology (positive rate: 35.7 %). Atypical lymphoid cells showed immunoreactivity for CD20 and Ki67. Seven cell block specimens were smear cytology-negative and cell block-positive. The cell block method showed no atypical lymphoid cells in any patient with idiopathic uveitis. Cell block specimens using diluted vitreous fluid demonstrated a high diagnostic sensitivity and a low pseudo-positive rate for the cytological diagnosis of VRL. The cell block method contributed to clear differentiation between VRL and idiopathic uveitis with vitreous opacity.
Kapo, Katherine E; McDonough, Kathleen; Federle, Thomas; Dyer, Scott; Vamshi, Raghu
2015-06-15
Environmental exposure and associated ecological risk related to down-the-drain chemicals discharged by municipal wastewater treatment plants (WWTPs) are strongly influenced by in-stream dilution of receiving waters which varies by geography, flow conditions and upstream wastewater inputs. The iSTREEM® model (American Cleaning Institute, Washington D.C.) was utilized to determine probabilistic distributions for no decay and decay-based dilution factors in mean annual and low (7Q10) flow conditions. The dilution factors derived in this study are "combined" dilution factors which account for both hydrologic dilution and cumulative upstream effluent contributions that will differ depending on the rate of in-stream decay due to biodegradation, volatilization, sorption, etc. for the chemical being evaluated. The median dilution factors estimated in this study (based on various in-stream decay rates from zero decay to a 1h half-life) for WWTP mixing zones dominated by domestic wastewater flow ranged from 132 to 609 at mean flow and 5 to 25 at low flow, while median dilution factors at drinking water intakes (mean flow) ranged from 146 to 2×10(7) depending on the in-stream decay rate. WWTPs within the iSTREEM® model were used to generate a distribution of per capita wastewater generated in the U.S. The dilution factor and per capita wastewater generation distributions developed by this work can be used to conduct probabilistic exposure assessments for down-the-drain chemicals in influent wastewater, wastewater treatment plant mixing zones and at drinking water intakes in the conterminous U.S. In addition, evaluation of types and abundance of U.S. wastewater treatment processes provided insight into treatment trends and the flow volume treated by each type of process. Moreover, removal efficiencies of chemicals can differ by treatment type. Hence, the availability of distributions for per capita wastewater production, treatment type, and dilution factors at a national level provides a series of practical and powerful tools for building probabilistic exposure models. Copyright © 2015 Elsevier B.V. All rights reserved.
Heydari, Ali; Razavi, Seyed Mohammad Ali; Irani, Mahdi
2018-03-01
In this paper, influence of temperature (25, 35, 45 and 55°C) and sugars (sucrose and lactose) at different concentrations (0, 5, 10 and 15%) on some molecular parameters of starches from two canary seed varieties (C05041 and CDC Maria) in the dilute regime were investigated in comparison to wheat starch (WS). The results indicated that the intrinsic viscosity ([η]) values of C05041, CDC Maria and WS samples were 1.42, 1.46 and 1.70dl/g at 25°C, respectively. Intrinsic viscosity of selected starches decreased with an increase in temperature, but the effect of high temperatures were somewhat unnoticeable. By increasing the sugar concentration, intrinsic viscosity of each starch solution significantly decreased in comparison with the value determined for sugar free solution. Lactose had more pronounced effect on the intrinsic viscosity reduction of CDC Maria starch and WS at 25°C and 35°C compared with sucrose (P<0.05). But at 55°C, the effect of increasing sucrose on decreasing of [η] of CDC Maria and WS samples were more considerable. The shape factor of starch samples at 25°C were spherical, but increasing temperature from 25°C to 55°C, CSSs and WS samples took an ellipsoidal shape. The interaction between starches and solvent/cosolutes is the predominant factors determining their functional properties in food systems. One of the aspects can help to understand the characteristic of biopolymers such as starches is determination of their dilute solution properties as a function of common additives which are used in food systems. As a matter of fact, dilute solution properties can help to understand the potential applications of biopolymers in food and non-food application. Attentively, dilute solution properties would give some priceless information about molecular properties, biopolymer behavior and its interaction with copolymers. For instance, intrinsic viscosity provides deep insight into fundamental properties of the solute and its interaction with the solvent and/or cosolutes, conformation of flexible chains. There are many studies which investigated the effect of different parameters such as temperature, salts and sugars on dilute solution properties of hydrocolloids, especially gums. Regrettably, few researches scrutinized the influence of various cosolutes on dilute solution properties of starch. Then in this paper, we studied the dilute solution properties of starches from two canary seed varieties (C05041 and CDC Maria), as a new potential source of starch, (CSSs), in comparison to wheat starch at different experimental conditions (temperatures and sugars at different concentrations) in order to shed light on its behavior in real system in comparison to wheat starch. Because of the unique properties of wheat starch, comparison of canary seed starch with wheat starch in dilute regime can help to having better vision of this new starch source. Overall, the intrinsic viscosity, coil dimensions (R coil and V coil ), swollen specific volume, shape function, and hydration parameter of selected starches were determined affected by temperature and sugars concentration treatments. The importance of these results will be cleared when taking into account the influence of crucial additives generally used in food systems, for instance, different sugars and/or frequent processing parameters such as temperature on rheological and functional properties. Copyright © 2017 Elsevier B.V. All rights reserved.
Declining ecosystem health and the dilution effect
Khalil, Hussein; Ecke, Frauke; Evander, Magnus; Magnusson, Magnus; Hörnfeldt, Birger
2016-01-01
The “dilution effect” implies that where species vary in susceptibility to infection by a pathogen, higher diversity often leads to lower infection prevalence in hosts. For directly transmitted pathogens, non-host species may “dilute” infection directly (1) and indirectly (2). Competitors and predators may (1) alter host behavior to reduce pathogen transmission or (2) reduce host density. In a well-studied system, we tested the dilution of the zoonotic Puumala hantavirus (PUUV) in bank voles (Myodes glareolus) by two competitors and a predator. Our study was based on long-term PUUV infection data (2003–2013) in northern Sweden. The field vole (Microtus agrestis) and the common shrew (Sorex araneus) are bank vole competitors and Tengmalm’s owl (Aegolius funereus) is a main predator of bank voles. Infection probability in bank voles decreased when common shrew density increased, suggesting that common shrews reduced PUUV transmission. Field voles suppressed bank vole density in meadows and clear-cuts and indirectly diluted PUUV infection. Further, Tengmalm’s owl decline in 1980–2013 may have contributed to higher PUUV infection rates in bank voles in 2003–2013 compared to 1979–1986. Our study provides further evidence for dilution effect and suggests that owls may have an important role in reducing disease risk. PMID:27499001
Effect of residual ascorbate on determination of nitrite in commercial cured meat products.
Fox, J B; Doerr, R C; Gates, R
1984-01-01
Residual ascorbate in cured meat slurries results in different amounts of pigment being produced from different Griess reagent combinations. The phenomenon was used to study residual ascorbate in commercial cured meat products which had a variety of textures, acidities, moisture and meat content, fat, homogeneity, initial nitrite, and processing conditions. Diluting and heating the samples according to the AOAC procedure did not completely eliminate the ascorbate interference, but making the sample alkaline did. Determining nitrite separately in supernate and precipitate from the first dilution showed the effect of heating to be the elimination of interferences and solubilization or extraction of nitrite from the precipitate.
Chiem, N H; Harrison, D J
1998-03-01
A glass microchip is described in which reagents and serum samples for competitive immunoassay of serum theophylline can be mixed, reacted, separated, and analyzed. The device functions as an automated microfluidic immunoassay system, creating a lab-on-a-chip. Electroosmotic pumping was used to control first the mixing of 50-fold-diluted serum sample with labeled theophylline tracer in a 1:1 ratio, followed by 1:1 mixing and reaction with anti-theophylline antibody. The 51-nL on-chip mixer gave the same concentration as dilution performed off-chip, within 3%. A 100-pL plug of the reacted solution was then injected into an electrophoresis separation channel integrated within the same chip. Measurements of free and bound tracer by fluorescence detection gave linear calibration curves of signal vs log[theophylline] between 0 and 40 mg/L, with a slope of 0.52 +/- 0.03 and an intercept of -0.04 +/- 0.04 after a 90-s reaction time. A detection limit of 0.26 mg/L in serum (expressed before the dilution step, actual concentration of 1.3 micrograms/L at the detector) was obtained. Recovery values were 107% +/- 8% for 15 mg/L serum samples.
Inoue, Ryo; Tsukahara, Takamitsu; Sunaba, Chinatsu; Itoh, Mitsugi; Ushida, Kazunari
2007-04-01
The combination of Flinders Technology Associates filter papers (FTA cards) and real-time PCR was examined to establish a simple and rapid technique for the detection of porcine reproductive and respiratory syndrome virus (PRRSV) from whole pig blood. A modified live PRRS vaccine was diluted with either sterilised saline or pig whole blood, and the suspensions were applied onto the FTA cards. The real-time RT-PCR detection of PRRSV was performed directly with the samples applied to the FTA card without the RNA extraction step. Six whole blood samples from at random selected piglets in the PRRSV infected farm were also assayed in this study. The expected PCR product was successfully amplified from either saline diluted or pig whole blood diluted vaccine. The same PCR ampliocon was detected from all blood samples assayed in this study. This study suggested that the combination of an FTA card and real-time PCR is a rapid and easy technique for the detection of PRRSV. This technique can remarkably shorten the time required for PRRSV detection from whole blood and makes the procedure much easier.
Tivapasi, Musavenga T; Hodges, Joanne; Byrne, Barbara A; Christopher, Mary M
2009-09-01
Urinary tract infections (UTIs) may be subclinical or difficult to detect in dilute urine as sediment abnormalities may not be observed. In our laboratory, bacterial culture is automatically performed (reflex culture) on samples with urine specific gravity (USG)< or =1.013 to increase the likelihood of detecting infection. The value of routine culture of dilute urine, however, has not been fully assessed. The purpose of this retrospective study was to evaluate the frequency of positive bacterial cultures and analyze the diagnostic utility and cost-effectiveness of culture compared with routine sediment examination for detecting UTI in dilute urine specimens from dogs. Urinalysis and concurrent aerobic bacterial culture results were obtained from the electronic medical record system at the University of California-Davis Veterinary Medical Teaching Hospital for samples with USG< or =1.013 analyzed from July 1998 through January 2005. Urine collection method, presence of leukocytes and bacteria, bacterial culture results, and clinical diagnosis were recorded. Cost-effectiveness of reflex culture, based on low USG as the sole criterion, was evaluated. Of 1264 urine specimens, 106 (8.4%) had positive bacterial cultures. Using culture as the gold standard, sediment evaluation had a diagnostic sensitivity of 58.5% and specificity of 98.3% (diagnostic accuracy 94.9%). An additional cost of $60 per patient was incurred, leading to average annual costs of $11,668 for reflex bacterial cultures of all samples with low USG, regardless of collection method. Within our study population, 10 urine samples needed to be cultured for each true positive result. The sensitivity of urine sediment evaluation is low for UTI in dilute urine samples; however, reflex bacterial culture does not appear to be cost-effective in dogs with USG< or =1.013 in the absence of active urine sediment or high clinical suspicion for UTI.
Infinitely Dilute Partial Molar Properties of Proteins from Computer Simulation
2015-01-01
A detailed understanding of temperature and pressure effects on an infinitely dilute protein’s conformational equilibrium requires knowledge of the corresponding infinitely dilute partial molar properties. Established molecular dynamics methodologies generally have not provided a way to calculate these properties without either a loss of thermodynamic rigor, the introduction of nonunique parameters, or a loss of information about which solute conformations specifically contributed to the output values. Here we implement a simple method that is thermodynamically rigorous and possesses none of the above disadvantages, and we report on the method’s feasibility and computational demands. We calculate infinitely dilute partial molar properties for two proteins and attempt to distinguish the thermodynamic differences between a native and a denatured conformation of a designed miniprotein. We conclude that simple ensemble average properties can be calculated with very reasonable amounts of computational power. In contrast, properties corresponding to fluctuating quantities are computationally demanding to calculate precisely, although they can be obtained more easily by following the temperature and/or pressure dependence of the corresponding ensemble averages. PMID:25325571
Pecly, José Otavio Goulart
2018-01-01
The alternative use of effluent turbidity to determine the dilution field of a domestic marine outfall located off the city of Rio de Janeiro was evaluated through field work comprising fluorescent dye tracer injection and tracking with simultaneous monitoring of sea water turbidity. A preliminary laboratory assessment was carried out with a sample of the outfall effluent whose turbidity was measured by the nephelometric method before and during a serial dilution process. During the field campaign, the dye tracer was monitored with field fluorometers and the turbidity was observed with an optical backscattering sensor interfaced to an OEM data acquisition system. About 4,000 samples were gathered, covering an area of 3 km × 3 km near the outfall diffusers. At the far field - where a drift towards the coastline was observed - the effluent plume was adequately labeled by the dye tracer. The turbidity plume was biased due to the high and variable background turbidity of sea water. After processing the turbidity dataset with a baseline detrending method, the plume presented high correlation with the dye tracer plume drawn on the near dilution field. However, dye tracer remains more robust than effluent turbidity.
Thermodynamic characteristics of the adsorption of organic molecules on modified MCM-41 adsorbents
NASA Astrophysics Data System (ADS)
Gus'kov, V. Yu.; Sukhareva, D. A.; Salikhova, G. R.; Karpov, S. I.; Kudasheva, F. Kh.; Roessner, F.; Borodina, E. V.
2017-07-01
The adsorption of a number of organic molecules on samples of MCM-41 adsorbent modified with dichloromethylphenylsilane and subsequently treated with sulfuric acid (MDCS) and N-trimethoxysilylpropyl- N, N, N-trimethylammonium chloride (MNM) is studied. Specific retention volumes equal to the Henry constant are determined by means of inverse gas chromatography at infinite dilution. The thermodynamic characteristics of adsorption, the dispersive and specific components of the Helmholtz energy of adsorption, and the increment of the methyl group to the heat of adsorption are calculated. It is shown that the grafting of aminosilane and phenylsilane groups enhances the forces of dispersion and reduces specific interactions. A greater drop in polarity is observed for MDCS than for MNM, due to the stronger polarity of amoinosilane; the enthalpy factor makes the main contribution to the adsorption of organic compounds on the investigated adsorbents. It is found that the MNM sample is capable of the irreversible adsorption of alcohols.
Application of environmental groundwater tracers at the Sulphur Bank Mercury Mine, California, USA
Engle, M.A.; Goff, F.; Jewett, D.G.; Reller, G.J.; Bauman, J.B.
2008-01-01
Boron, chloride, sulfate, ??D, ??18O, and 3H concentrations in surface water and groundwater samples from the Sulphur Bank Mercury Mine (SBMM), California, USA were used to examine geochemical processes and provide constraints on evaporation and groundwater flow. SBMM is an abandoned sulfur and mercury mine with an underlying hydrothermal system, adjacent to Clear Lake, California. Results for non-3H tracers (i.e., boron, chloride, sulfate, ??D, and ??18O) identify contributions from six water types at SBMM. Processes including evaporation, mixing, hydrothermal water input and possible isotopic exchange with hydrothermal gases are also discerned. Tritium data indicate that hydrothermal waters and other deep groundwaters are likely pre-bomb (before ???1952) in age while most other waters were recharged after ???1990. A boron-based steady-state reservoir model of the Herman Impoundment pit lake indicates that 71-79% of its input is from meteoric water with the remainder from hydrothermal contributions. Results for groundwater samples from six shallow wells over a 6-month period for ??D and ??18O suggests that water from Herman Impoundment is diluted another 3% to more than 40% by infiltrating meteoric water, as it leaves the site. Results for this investigation show that environmental tracers are an effective tool to understand the SBMM hydrogeologic regime. ?? Springer-Verlag 2007.
NASA Technical Reports Server (NTRS)
Garland, J. L.; Mills, A. L.; Young, J. S.
2001-01-01
The relative effectiveness of average-well-color-development-normalized single-point absorbance readings (AWCD) vs the kinetic parameters mu(m), lambda, A, and integral (AREA) of the modified Gompertz equation fit to the color development curve resulting from reduction of a redox sensitive dye from microbial respiration of 95 separate sole carbon sources in microplate wells was compared for a dilution series of rhizosphere samples from hydroponically grown wheat and potato ranging in inoculum densities of 1 x 10(4)-4 x 10(6) cells ml-1. Patterns generated with each parameter were analyzed using principal component analysis (PCA) and discriminant function analysis (DFA) to test relative resolving power. Samples of equivalent cell density (undiluted samples) were correctly classified by rhizosphere type for all parameters based on DFA analysis of the first five PC scores. Analysis of undiluted and 1:4 diluted samples resulted in misclassification of at least two of the wheat samples for all parameters except the AWCD normalized (0.50 abs. units) data, and analysis of undiluted, 1:4, and 1:16 diluted samples resulted in misclassification for all parameter types. Ordination of samples along the first principal component (PC) was correlated to inoculum density in analyses performed on all of the kinetic parameters, but no such influence was seen for AWCD-derived results. The carbon sources responsible for classification differed among the variable types with the exception of AREA and A, which were strongly correlated. These results indicate that the use of kinetic parameters for pattern analysis in CLPP may provide some additional information, but only if the influence of inoculum density is carefully considered. c2001 Elsevier Science Ltd. All rights reserved.
Pietilä, Heidi; Perämäki, Paavo; Piispanen, Juha; Starr, Mike; Nieminen, Tiina; Kantola, Marjatta; Ukonmaanaho, Liisa
2015-04-01
Most often, only total mercury concentrations in soil samples are determined in environmental studies. However, the determination of extremely toxic methylmercury (MeHg) in addition to the total mercury is critical to understand the biogeochemistry of mercury in the environment. In this study, N2-assisted distillation and acidic KBr/CuSO4 solvent extraction methods were applied to isolate MeHg from wet peat soil samples collected from boreal forest catchments. Determination of MeHg was performed using a purge and trap GC-ICP-MS technique with a species-specific isotope dilution quantification. Distillation is known to be more prone to artificial MeHg formation compared to solvent extraction which may result in the erroneous MeHg results, especially with samples containing high amounts of inorganic mercury. However, methylation of inorganic mercury during the distillation step had no effect on the reliability of the final MeHg results when natural peat soil samples were distilled. MeHg concentrations determined in peat soil samples after distillation were compared to those determined after the solvent extraction method. MeHg concentrations in peat soil samples varied from 0.8 to 18 μg kg(-1) (dry weight) and the results obtained with the two different methods did not differ significantly (p=0.05). The distillation method with an isotope dilution GC-ICP-MS was shown to be a reliable method for the determination of low MeHg concentrations in unpolluted soil samples. Furthermore, the distillation method is solvent-free and less time-consuming and labor-intensive when compared to the solvent extraction method. Copyright © 2014 Elsevier Ltd. All rights reserved.
High-throughput method to predict extrusion pressure of ceramic pastes.
Cao, Kevin; Liu, Yang; Tucker, Christopher; Baumann, Michael; Grit, Grote; Lakso, Steven
2014-04-14
A new method was developed to measure the rheology of extrudable ceramic pastes using a Hamilton MicroLab Star liquid handler. The Hamilton instrument, normally used for high throughput liquid processing, was expanded to function as a low pressure capillary rheometer. Diluted ceramic pastes were forced through the modified pipettes, which produced pressure drop data that was converted to standard rheology data. A known ceramic paste containing cellulose ether was made and diluted to various concentrations in water. The most dilute paste samples were tested in the Hamilton instrument and the more typical, highly concentrated, ceramic paste were tested with a hydraulic ram extruder fitted with a capillary die and pressure measurement system. The rheology data from this study indicates that the dilute high throughput method using the Hamilton instrument correlates to, and can predict, the rheology of concentrated ceramic pastes normally used in ceramic extrusion production processes.
Oliveira, Karol G; Miranda, Stefania A; Leão, Danuza L; Brito, Adriel B; Santos, Regiane R; Domingues, Sheyla F S
2011-01-01
The objectives of the present study were to test the effect of coconut water solution and TES-TRIS on the seminal coagulum liquefaction, sperm activation in fresh diluted semen, and on the cryopreservation of semen from capuchin monkeys (Cebus apella). Semen was collected from six males by electro-ejaculation, diluted in TES-TRIS or coconut water solution (CWS), and incubated at 35°C until the coagulated fraction of the semen was completely liquefied. In the experiment I, after liquefaction, samples were diluted in TES-TRIS or CWS, plus 6 and 10mM/mL of caffeine. Sperm motility and vigor were evaluated during 5h. For experiment II, after liquefaction, semen samples were extended in TES-TRIS (3.5% glycerol in the final solution) or CWS (2.5% glycerol in the final solution), cryopreserved and stored in liquid nitrogen for 1 week. The seminal coagulum was liquefied in (mean±SDM) 4.5±1.7 and 2.8±1.1h in TES-TRIS and CWS, respectively. Sperm were motile in TES-TRIS and CWS for 5.0±1.4 and 1.0±0.5h, respectively. The mean motility in this period was 38±22% (TES-TRIS) and 22.0±16.0 (CWS). Motility increased after caffeine addition only in samples diluted in CWS containing 6mM (22.5±16.0) or 10mM (28.0±19.0) caffeine. Post-thaw live sperm percentage was 26.2% in TES-TRIS and 13.2% in CWS. For cryopreservation of semen from C. apella TES-TRIS (3.5% glycerol) was more appropriate than CWS (2.5% glycerol). CWS+caffeine potentially increase sperm motility and may be useful in artificial insemination of fresh diluted semen. Copyright © 2010 Elsevier B.V. All rights reserved.
Wang, Hongxin; Friedrich, Stephan; Li, Lei; Mao, Ziliang; Ge, Pinghua; Balasubramanian, Mahalingam; Patil, Daulat S
2018-03-28
According to L-edge sum rules, the number of 3d vacancies at a transition metal site is directly proportional to the integrated intensity of the L-edge X-ray absorption spectrum (XAS) for the corresponding metal complex. In this study, the numbers of 3d holes are characterized quantitatively or semi-quantitatively for a series of manganese (Mn) and nickel (Ni) complexes, including the electron configurations 3d 10 → 3d 0 . In addition, extremely dilute (<0.1% wt/wt) Ni enzymes were examined by two different approaches: (1) by using a high resolution superconducting tunnel junction X-ray detector to obtain XAS spectra with a very high signal-to-noise ratio, especially in the non-variant edge jump region; and (2) by adding an inert tracer to the sample that provides a prominent spectral feature to replace the weak edge jump for intensity normalization. In this publication, we present for the first time: (1) L-edge sum rule analysis for a series of Mn and Ni complexes that include electron configurations from an open shell 3d 0 to a closed shell 3d 10 ; (2) a systematic analysis on the uncertainties, especially on that from the edge jump, which was missing in all previous reports; (3) a clearly-resolved edge jump between pre-L 3 and post-L 2 regions from an extremely dilute sample; (4) an evaluation of an alternative normalization standard for L-edge sum rule analysis. XAS from two copper (Cu) proteins measured using a conventional semiconductor X-ray detector are also repeated as bridges between Ni complexes and dilute Ni enzymes. The differences between measuring 1% Cu enzymes and measuring <0.1% Ni enzymes are compared and discussed. This study extends L-edge sum rule analysis to virtually any 3d metal complex and any dilute biological samples that contain 3d metals.
Effect of hen's egg yolk on capacitation and acrosome reaction of diluted canine spermatozoa.
Witte, T S; Schäfer-Somi, S; Kuchar, A; Möstl, E; Iben, C; Aurich, C
2009-02-01
The aim of this study was to investigate the influence of progesterone, cholesterol and calcium (Ca(2+)) in an egg-yolk-containing extender on capacitation and acrosome reactions (AR) of diluted canine spermatozoa during 4 days of cooled-storage. For this purpose, we first investigated the effect of supplementation of a Tris-citrate-fructose buffer (TCF) with progesterone in a final concentration of 0.1, 0.2 and 1.0 microg progesterone/ml TCF-diluted semen. We then compared the effects of TCF and the same buffer-containing 20% egg yolk (TCF-EY). In egg yolks and the TCF-EY, progesterone was measured by enzyme immunoassay, cholesterol by enzymatic colorimetry and Ca(2+) by flame atomic absorption spectrophotometry. For both experiments, ejaculates from eight dogs were used. For the comparison of diluents, one ejaculate was divided and one half diluted with TCF, the other with TCF-EY. One half of each TCF- and TCF-EY-diluted sample was evaluated immediately (D1), the other after storage for 4 days at +4 degrees C (D4). In diluted semen, motility and viability were measured by a computer assisted sperm analyzer (CASA; Sperm Vision, Minitüb, Germany), capacitation and AR were evaluated with a modified chlortetracycline assay (CTC) and the AR additionally by flow cytometry. Supplementation of progesterone revealed, that between D1 and D4, total and progressive motility decreased with all progesterone concentrations, while viability as well as percentage of capacitated and acrosome reacted spermatozoa stayed constant. Progesterone-, cholesterol- and Ca(2+) concentrations in egg yolks were 524.8+/-131.4 ng/g, 13.9+/-2.03 mg/g and 1.27+/-0.17 mg/g, respectively. In the TCF-EY-diluent, the respective values were 210.9 ng/g, 2.52 mg/g and 1.1mg/g. In TCF-semen, at D1, motility and viability were significantly higher than in TCF-EY-samples (p<0.05), however at D4, no significant differences were detectable. Further, in TCF-semen, percentages of spermatozoa with intact membranes decreased significantly (p<0.05) and capacitated spermatozoa increased (p<0.05), which was not seen in TCF-EY-samples. In all samples, low percentages of AR were detected and after 4 days, the highest value of AR in TCF-EY-samples was 5.3% on average, as detected by flow cytometry. We therefore conclude that progesterone from egg yolk in routine extenders does not substantially influence semen longevity or AR of canine semen during cold-storage for 4 days. In contrary, egg yolk seems to prevent a significant increase in capacitated spermatozoa.
40 CFR 86.1537 - Idle test run.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Heavy-Duty Engines, New Methanol-Fueled Natural Gas-Fueled, and Liquefied Petroleum Gas-Fueled Diesel-Cycle Heavy-Duty Engines, New Otto-Cycle Light-Duty Trucks, and New Methanol-Fueled Natural Gas-Fueled... dilute sampling. (6) For bag sampling, sample idle emissions long enough to obtain a sufficient bag...
Sampling emissions from open area sources, particularly sources of open burning, is difficult due to fast dilution of emissions and safety concerns for personnel. Representative emission samples can be difficult to obtain with flaming and explosive sources since personnel safety ...
Stability of levothyroxine sodium 0.4 microg/mL in 0.9% sodium chloride injection.
Stadalman, Kelli A; Kelner, Michael J; Box, Kevin; Dominguez, Alex; Rigby, Joseph F
2009-12-01
Intravenous levothyroxine therapy decreases vasopressor requirements and prevents cardiovascular collapse in hemodynamically unstable patients eligible for organ donation. The stability of levothyroxine when used in this manner is unknown. To determine the stability of levothyroxine solution for intravenous use at a concentration of 0.4 microg/mL diluted in 0.9% sodium chloride. Triplicate sample sets were prepared by reconstituting levothyroxine 200 microg for injection with 5 mL of 0.9% sodium chloride with further dilution in 500 mL of 0.9% sodium chloride. One sample set was protected from light and the other was left unprotected. Both sample sets were stored at room temperature, and samples from each were analyzed for initial concentration and 4, 8, 12, and 24 hours later. Levothyroxine sodium 0.4 microg/mL in 500 mL 0.9% sodium chloride is stable for 24 hours at room temperature when protected from light.
Gil, A.; González, A.; Dal-Ré, R.; Dominguez, V.; Astasio, P.; Aguilar, L.
1997-01-01
Diluted dried blood drops on filter paper were compared with serum samples as a specimen source for qualitative anti-HAV antibody determination by ELISA. A total of 298 serum samples and dried blood drops were collected from a population of healthy adolescents (15.3 +/- 1.2 years old). The prevalence of anti-HAV antibody obtained by testing serum samples was 7.7% (95% CI:4.8 10.1). Compared with serum sampling the sensitivity and specificity of diluted dried blood drops were 91.3 and 99.3%. The positive and negative predictive values were 91.3 and 99.3%, respectively, and the likelihood ratios of positive and negative results were 91 and 0.09. It is proposed that this test represents a reliable procedure for anti-HAV antibody testing. PMID:9129596
Stability of florfenicol in drinking water.
Hayes, John M; Eichman, Jonathan; Katz, Terry; Gilewicz, Rosalia
2003-01-01
Florfenicol, a broad-spectrum antibiotic, is being developed for veterinary application as an oral concentrate intended for dilution with drinking water. When a drug product is dosed via drinking water in a farm setting, a number of variables, including pH, chlorine content, hardness of the water used for dilution, and container material, may affect its stability, leading to a decrease in drug potency. The stability of florfenicol after dilution of Florfenicol Drinking Water Concentrate Oral Solution, 23 mg/mL, with drinking water was studied. A stability-indicating, validated liquid chromatographic method was used to evaluate florfenicol stability at 25 degrees C at 5, 10, and 24 h after dilution. The results indicate that florfenicol is stable under a range of simulated field conditions, including various pipe materials and conditions of hard or soft and chlorinated or nonchlorinated water at low or high pH. Significant degradation (> 10%) was observed only for isolated combinations in galvanized pipes. Analysis indicated that the florfenicol concentration in 8 of the 12 water samples stored in galvanized pipes remained above 90% of the initial concentration (100 mg/L) for 24 h after dilution.
Raeisi, Javad; Saifi, Mahnaz; Pourshafie, Mohammad Reza; Habibi, Mehri; Mohajerani, Hamid Reza; Akbari, Neda
2017-01-01
Introduction Vancomycin Resistant Enterococci (VRE) can be found all over the world. Thus, rapid detection of the isolates could be of high importance in the treatment or prevention of the associated disease. Aim To measure the turanose fermentation in Enterococcus faecalis clinical isolates for rapid differentiation of VRE and Vancomycin-Susceptible E. faecalis (VSE) isolates. Materials and Methods Forty E. faecalis samples were isolated from 200 clinical samples in Tehran Medical Center, Iran, from October 2012 to December 2012. These isolates were detected according to the standard microbial and biochemical tests. Detection of VRE isolates was originally performed by disk diffusion using 1 μg vancomycin disk, followed by Polymerase Chain Reaction (PCR) amplification of the vanA gene. Finally, the turanose consumption in 1%, 0.7% and 0.5% dilutions was detected by a phenotypic method. Results Among the 40 E. faecalis isolates, 20 vancomycin-susceptible and 20 vancomycin-resistant E. faecalis were isolated according to the disk diffusion and PCR of the vanA gene. There was a considerable difference between VRE and VSE isolates in 0.7% dilution of turanose. However, there was no significant difference between VRE and VSE in 1% and 0.5% dilutions of turanose. Conclusion Since detection of VRE isolates is of high importance, especially in nosocomial infections, phenotypic methods may be highly useful for this purpose. In conclusion, our data indicate that VRE isolated from clinical samples could be distinguished from VSE isolates by turanose fermentation at dilution 0.7%. PMID:28511382
A novel way to monitor urine concentration: fluorescent concentration matrices.
Dubayova, Katarina; Luckova, Iveta; Sabo, Jan; Karabinos, Anton
2015-01-01
The amount of water found in urine is important diagnostic information; nevertheless it is not yet directly determined. Indirectly, the water content in urine is expressed by its density (specific gravity). However, without the diuresis value it is not possible to determine whether the increase in density of urine is due to a decrease in water secretion or an increase in the concentration of secreted substances. This problem can be solved by the use of fluorescent concentration 3D-matrices which characterise urine concentration through the pφ (or -logφ) value of the first fluorescence centre. The urine fluorescent concentration 3D-matrix was created by the alignment of the synchronous spectra of the dilution series of urine starting from undiluted (pφ = 0) to 1000-fold diluted urine (pφ = 3). Using the fluorescence concentration 3D-matrix analysis of the urine samples from healthy individuals, a reference range was established for the value pφ, determining the normal, concentrated or diluted type of urine. The diagnostic potential of this approach was tested on urine samples from two patients with a chronic glomerulonephritis. The pφ value of the urine fluorescence concentration 3D-matrix analysis determines whether the urine sample falls within the normal, concentrated or diluted type of urine. This parameter can be directly utilised in sportsmen's hydration state monitoring, as well as in the diagnosis and treatment of serious diseases. An important advantage of this novel diagnostic approach is that a 12/24 h urine collection is not required, which predetermines it for use especially within paediatrics.
Observations and analysis of organic aerosol evolution in some prescribed fire smoke plumes
NASA Astrophysics Data System (ADS)
May, A. A.; Lee, T.; McMeeking, G. R.; Akagi, S.; Sullivan, A. P.; Urbanski, S.; Yokelson, R. J.; Kreidenweis, S. M.
2015-06-01
Open biomass burning is a significant source of primary air pollutants such as particulate matter (PM) and non-methane organic gases (NMOG). However, the physical and chemical atmospheric processing of these emissions during transport is poorly understood. Atmospheric transformations of biomass burning emissions have been investigated in environmental chambers, but there have been limited opportunities to investigate these transformations in the atmosphere. In this study, we deployed a suite of real-time instrumentation on a Twin Otter aircraft to sample smoke from prescribed fires in South Carolina, conducting measurements at both the source and downwind to characterize smoke evolution with atmospheric aging. Organic aerosol (OA) within the smoke plumes was quantified using an aerosol mass spectrometer (AMS); refractory black carbon (rBC) was quantified using a single-particle soot photometer, and carbon monoxide (CO) and carbon dioxide (CO2) were measured using a cavity ring-down spectrometer. During the two fires for which we were able to obtain aerosol aging data, normalized excess mixing ratios and "export factors" of conserved species (rBC, CO, CO2) suggested that changes in emissions at the source did not account for most of the differences observed in samples of increasing age. An investigation of AMS mass fragments indicated that the in-plume fractional contribution (fm/z) to OA of the primary fragment (m/z 60) decreased downwind, while the fractional contribution of the secondary fragment (m/z 44) increased. Increases in f44 are typically interpreted as indicating chemical aging of OA. Likewise, we observed an increase in the O : C elemental ratio downwind, which is usually associated with aerosol aging. However, the rapid mixing of these plumes into the background air suggests that these chemical transformations may be attributable to the different volatilities of the compounds that fragment to these m/z in the AMS. The gas-particle partitioning behavior of the bulk OA observed during the study was consistent with the predictions from a parameterization developed for open biomass burning emissions in the laboratory. Furthermore, we observed no statistically significant increase in total organic mass with atmospheric transport. Hence, our results suggest that dilution-driven evaporation likely dominated over the chemical production of secondary organic aerosol (SOA) within our smoke plumes, presumably due to the fast dilution and limited aging times (< ~ 5 h) that we could sample.
De Spiegelaere, Ward; Malatinkova, Eva; Lynch, Lindsay; Van Nieuwerburgh, Filip; Messiaen, Peter; O'Doherty, Una; Vandekerckhove, Linos
2014-06-01
Quantification of integrated proviral HIV DNA by repetitive-sampling Alu-HIV PCR is a candidate virological tool to monitor the HIV reservoir in patients. However, the experimental procedures and data analysis of the assay are complex and hinder its widespread use. Here, we provide an improved and simplified data analysis method by adopting binomial and Poisson statistics. A modified analysis method on the basis of Poisson statistics was used to analyze the binomial data of positive and negative reactions from a 42-replicate Alu-HIV PCR by use of dilutions of an integration standard and on samples of 57 HIV-infected patients. Results were compared with the quantitative output of the previously described Alu-HIV PCR method. Poisson-based quantification of the Alu-HIV PCR was linearly correlated with the standard dilution series, indicating that absolute quantification with the Poisson method is a valid alternative for data analysis of repetitive-sampling Alu-HIV PCR data. Quantitative outputs of patient samples assessed by the Poisson method correlated with the previously described Alu-HIV PCR analysis, indicating that this method is a valid alternative for quantifying integrated HIV DNA. Poisson-based analysis of the Alu-HIV PCR data enables absolute quantification without the need of a standard dilution curve. Implementation of the CI estimation permits improved qualitative analysis of the data and provides a statistical basis for the required minimal number of technical replicates. © 2014 The American Association for Clinical Chemistry.
Doret, Muriel; Cartier, Régine; Miribel, Juliette; Massardier, Jérome; Massoud, Mona; Bordes, Agnès; Moret, Stéphanie; Gaucherand, Pascal
2013-12-01
Previable premature rupture of the membranes (pPROM), occurring before 24WG, is associated with a 25% neonatal survival rate. This terrible prognosis may lead to elective pregnancy termination on parents' request. Therefore, certain diagnosis is essential but remains difficult in about 10% of patients. Bed-side biochemical tests developed to help in diagnosis had never been evaluated in early pregnancies. This study aimed to evaluate and compare the in vitro sensitivity, detection limit, reaction time and consistency of AmniSure detecting placental alpha microglobulin-1 (PAMG-1) and actim PROM detecting Insulin Growth Factor Binding Protein-1 (IGFBP-1) in amniotic fluid between 15 and 20weeks of gestation (WG). Samples of amniotic fluid were collected by amniocentesis performed between 15 and 20 completed WG in 55 patients. Dilution series were prepared and both tests were performed twice at each dilution. In vitro sensitivity, detection limit, and reaction time were evaluated and compared in serial dilution. A total of 460 AmniSure and 476 actim PROM tests were performed. Both tests' in vitro sensitivity was 100% at dilution 1:20 and remained up to 90% until dilution 1:80. In vitro sensitivities were not different at any dilution. Detection limit and consistency were similar for both tests at all dilution. Actim PROM reaction time was shorter than AmniSure at all dilutions, except 1:320 (p<0.05). PAMG-1 and IGFBP-1 can be detected in amniotic fluid between 15 and 20 completed WG, using respectively AmniSure and actim PROM. © 2013.
Sampling depth confounds soil acidification outcomes
USDA-ARS?s Scientific Manuscript database
In the northern Great Plains (NGP) of North America, surface sampling depths of 0-15 or 0-20 cm are suggested for testing soil characteristics such as pH. However, acidification is often most pronounced near the soil surface. Thus, sampling deeper can potentially dilute (increase) pH measurements an...
Evaluation of a portable test system for assessing endotoxin activity in raw milk
SUZUKI, Yohko; SUZUKI, Kazuyuki; SHIMAMORI, Toshio; TSUCHIYA, Masakazu; NIEHAUS, Andrew; LAKRITZ, Jeffrey
2015-01-01
The aim of the present study was to compare endotoxin activities detected in raw milk samples obtained from cattle by a commercially available portable test system (PTS) and traditional microplate limulus amebocyte lysate (LAL)-based assay, which determined activities using a kinetic turbidimetric (KT) assay. Raw milk samples were obtained from 53 and 12 dairy cattle without and with clinical mastitis, respectively. Comparison between the KT and PTS was performed by the Friedman test. The Pearson product moment correlation coefficients were calculated to evaluate associations between any two continuous variables. Linear regression model analysis was also performed to obtain the equation describing the relationship between PTS and KT assay. The endotoxin activities detected in 200- or 400-fold diluted milk samples were similar between PTS and KT assay, whereas a significant difference was observed in 100-fold diluted milk (P<0.001). The results obtained from 200- (r2=0.778, P<0.001) and 400-fold diluted milk samples (r2=0.945, P<0.001) using PTS correlated with those using KT assay. The median milk endotoxin activities in Gram-positive and Gram-negative clinical mastitis cows were 0.655 and 11,523.5 EU/ml, respectively. The results of the present study suggest that PTS as a simple and easy test to assess endotoxin activity in raw milk is efficient, simple and reproducible. PMID:26279135
Griego-Valles, Michelle; Buriko, Yekaterina; Prittie, Jennifer E; Fox, Philip R
2017-01-01
To assess primary and secondary hemostasis following in vitro dilution of canine whole blood (WB) with hydroxyethyl starch (HES) 130/0.4 and HES 670/0.75. In vitro experimental study. Private practice, teaching hospital. Twenty-five healthy dogs. Each dog underwent venipuncture and 18 mL of venous blood was sampled once. Collected blood was separated in 4 aliquots. Aliquot A served as baseline sample. The remaining tubes of WB were diluted with 0.9% saline, HES 670/0.75 and HES 130/0.4 at a ratio of 1:5.5. Dilutional effects were evaluated using prothrombin time (PT), activated partial thromboplastin time (aPTT), packed cell volume (PCV), thromboelastography (TEG), and platelet closure time (Ct), which was measured using a platelet function analyzer (PFA). Clot strength (ie, G value) was calculated from measured TEG values. Significant increases in PT (P < 0.05) and aPTT (P < 0.05) were documented following WB dilution with saline. Dilution of WB with HES 670/0.75 and HES 130/0.4 resulted in significant hypocoagulable changes in K, MA and G (P < 0.05) compared to baseline and saline. When comparing saline to HES 670/0.75, both R and K values were significantly increased (P < 0.05). K value was significantly increased (P < 0.05) when comparing baseline to HES 130/0.4 and HES 670/0.75. Ct (P < 0.05) was significantly prolonged after WB dilution with HES solutions but not after saline. Dilution of WB with HES 670/0.75 and HES 130/0.4 resulted in changes in primary and secondary hemostasis. Although there were small differences between saline and HES 670/0.75, no differences between HES solutions were evident in this small study. This may suggest there would be minimal increases in bleeding risk when either solution is administered to dogs at low doses. Clinical relevance of our findings requires further investigation. © Veterinary Emergency and Critical Care Society 2016.
NASA Astrophysics Data System (ADS)
Elilarassi, R.; Chandrasekaran, G.
2017-11-01
In the present investigation, diluted magnetic semiconductor (Zn1-xFexO) nanoparticles with different doping concentrations (x = 0, 0.02, 0.04, 0.06, and 0.08) were successfully synthesized by sol-gel auto-combustion method. The crystal structure, morphology, optical, electrical and magnetic properties of the prepared samples were characterized by X-ray diffraction (XRD), scanning electron microscope (SEM), energy dispersive analysis using x-rays (EDAX), ultraviolet-visible spectrophotometer, fluorescence spectroscope (FS), vibrating sample magnetometer (VSM) and broad band dielectric spectrometer (BDS). XRD results reveal that all the samples possess hexagonal wurtzite crystal structure with good crystalline quality. The absence of impurity phases divulge that Fe ions are well incorporated into the ZnO crystal lattice. The substitutional incorporation of Fe3+ at Zn sites is reflected in optical absorption spectra of the samples. Flouorescence spectra of the samples show a strong near-band edge related UV emission as well as defect related visible emissions. The semiconducting behavior of the samples has been confirmed through electrical conductivity measurements. Magnetic measurements indicated that all the samples possess ferromagnetism at room temperature.
da Silva, Wesley Pereira; de Oliveira, Luiz Henrique; Santos, André Luiz Dos; Ferreira, Valdir Souza; Trindade, Magno Aparecido Gonçalves
2018-06-01
A procedure based on liquid-liquid extraction (LLE) and phase separation using magnetically stirred salt-induced high-temperature liquid-liquid extraction (PS-MSSI-HT-LLE) was developed to extract and pre-concentrate ciprofloxacin (CIPRO) and enrofloxacin (ENRO) from animal food samples before electroanalysis. Firstly, simple LLE was used to extract the fluoroquinolones (FQs) from animal food samples, in which dilution was performed to reduce interference effects to below a tolerable threshold. Then, adapted PS-MSSI-HT-LLE protocols allowed re-extraction and further pre-concentration of target analytes in the diluted acid samples for simultaneous electrochemical quantification at low concentration levels. To improve the peak separation, in simultaneous detection, a baseline-corrected second-order derivative approach was processed. These approaches allowed quantification of target FQs from animal food samples spiked at levels of 0.80 to 2.00 µmol L -1 in chicken meat, with recovery values always higher than 80.5%, as well as in milk samples spiked at 4.00 µmol L -1 , with recovery values close to 70.0%. Copyright © 2018 Elsevier Ltd. All rights reserved.
Characterization of the key aroma compounds in beef extract using aroma extract dilution analysis.
Takakura, Yukiko; Sakamoto, Tomohiro; Hirai, Sachi; Masuzawa, Takuya; Wakabayashi, Hidehiko; Nishimura, Toshihide
2014-05-01
Aroma extract dilution analysis (AEDA) of an ether extract prepared from beef extract (BE) and subsequent identification experiments led to the determination of seven aroma-active compounds in the flavor dilution (FD) factor range of 32-128. Omission experiments to select the most aroma-active compounds from the seven aroma compounds suggested that 2,3,5-trimethyl pyrazine, 1-octen-3-ol, 3-methylbutanoic acid, and 4-hydroxy-2,5-dimethyl-3(2H)-furanone were the main active compounds contributing to the aroma of BE. Aroma recombination, addition, and omission experiments of the four aroma compounds in taste-reconstituted BE showed that each compound had an individual aroma profile. A comparison of the overall aroma between this recombination mixture and BE showed a high similarity, suggesting that the key aroma compounds had been identified successfully. Copyright © 2014 Elsevier Ltd. All rights reserved.
Demangeat, Jean-Louis
2013-04-01
proton nuclear magnetic resonance (NMR) relaxation times T1, T2, T1/T2 are sensitive to motion and organization of water molecules. Especially, increase in T1/T2 reflects a higher degree of structuring. My purpose was to look at physical changes in water in ultrahigh aqueous dilutions. Samples were prepared by iterative centesimal (c) dilution with vigorous agitation, ranging between 3c and 24c (Avogadro limit 12c). Solutes were silica-lactose, histamine, manganese-lactose. Solvents were water, NaCl 0.15 M or LiCl 0.15 M. Solvents underwent strictly similar, simultaneous dilution/agitation, for each level of dilution, as controls. NMR relaxation was studied within 0.02-20 MHz. No changes were observed in controls. Increasing T1 and T1/T2 were found in dilutions, which persisted beyond 9c (manganese-lactose), 10c (histamine) and 12c (silica-lactose). For silica-lactose in LiCl, continuous decrease in T2 with increase in T1/T2 within the 12c-24c range indicated growing structuring of water despite absence of the initial solute. All changes vanished after heating/cooling. These findings were interpreted in terms of nanosized (>4-nm) supramolecular structures involving water, nanobubbles and ions, if any. Additional study of low dilutions of silica-lactose revealed increased T2 and decreased T1/T2 compared to solvent, within the 10(-3)-10(-6) range, reflecting transient solvent destructuring. This could explain findings at high dilution. Proton NMR relaxation demonstrated modifications of the solvent throughout the low to ultramolecular range of dilution. The findings suggested the existence of superstructures that originate stereospecifically around the solute after an initial destructuring of the solvent, developing more upon dilution and persisting beyond 12c. Copyright © 2013 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.
Linking manipulative experiments to field data to test the dilution effect.
Venesky, Matthew D; Liu, Xuan; Sauer, Erin L; Rohr, Jason R
2014-05-01
The dilution effect, the hypothesis that biodiversity reduces disease risk, has received support in many systems. However, few dilution effect studies have linked mechanistic experiments to field patterns to establish both causality and ecological relevance. We conducted a series of laboratory experiments and tested the dilution effect hypothesis in an amphibian-Batrachochytrium dendrobatidis (Bd) system and tested for consistency between our laboratory experiments and field patterns of amphibian species richness, host identity and Bd prevalence. In our laboratory experiments, we show that tadpoles can filter feed Bd zoospores and that the degree of suspension feeding was positively associated with their dilution potential. The obligate suspension feeder, Gastrophryne carolinensis, generally diluted the risk of chytridiomycosis for tadpoles of Bufo terrestris and Hyla cinerea, whereas tadpoles of B. terrestris (an obligate benthos feeder) generally amplified infections for the other species. In addition, G. carolinensis reduced Bd abundance on H. cinerea more so in the presence than absence of B. terrestris and B. terrestris amplified Bd abundance on H. cinerea more so in the absence than presence of G. carolinensis. Also, when ignoring species identity, species richness was a significant negative predictor of Bd abundance. In our analysis of field data, the presence of Bufo spp. and Gastrophryne spp. were significant positive and negative predictors of Bd prevalence, respectively, even after controlling for climate, vegetation, anthropogenic factors (human footprint), species richness and sampling effort. These patterns of dilution and amplification supported our laboratory findings, demonstrating that the results are likely ecologically relevant. The results from our laboratory and field data support the dilution effect hypothesis and also suggest that dilution and amplification are predictable based on host traits. Our study is among the first to link manipulative experiments, in which a potential dilution mechanism is supported, with analyses of field data on species richness, host identity, spatial autocorrelation and disease prevalence. © 2013 The Authors. Journal of Animal Ecology © 2013 British Ecological Society.
Pleil, Joachim D; Angrish, Michelle M; Madden, Michael C
2015-12-11
Immunochemistry is an important clinical tool for indicating biological pathways leading towards disease. Standard enzyme-linked immunosorbent assays (ELISA) are labor intensive and lack sensitivity at low-level concentrations. Here we report on emerging technology implementing fully-automated ELISA capable of molecular level detection and describe application to exhaled breath condensate (EBC) samples. The Quanterix SIMOA HD-1 analyzer was evaluated for analytical performance for inflammatory cytokines (IL-6, TNF-α, IL-1β and IL-8). The system was challenged with human EBC representing the most dilute and analytically difficult of the biological media. Calibrations from synthetic samples and spiked EBC showed excellent linearity at trace levels (r(2) > 0.99). Sensitivities varied by analyte, but were robust from ~0.006 (IL-6) to ~0.01 (TNF-α) pg ml(-1). All analytes demonstrated response suppression when diluted with deionized water and so assay buffer diluent was found to be a better choice. Analytical runs required ~45 min setup time for loading samples, reagents, calibrants, etc., after which the instrument performs without further intervention for up to 288 separate samples. Currently, available kits are limited to single-plex analyses and so sample volumes require adjustments. Sample dilutions should be made with assay diluent to avoid response suppression. Automation performs seamlessly and data are automatically analyzed and reported in spreadsheet format. The internal 5-parameter logistic (pl) calibration model should be supplemented with a linear regression spline at the very lowest analyte levels, (<1.3 pg ml(-1)). The implementation of the automated Quanterix platform was successfully demonstrated using EBC, which poses the greatest challenge to ELISA due to limited sample volumes and low protein levels.
de Lima Stebbins, Daniela; Docs, Jon; Lowe, Paula; Cohen, Jason; Lei, Hongxia
2016-05-18
The hormones listed in the screening survey list 2 of the Unregulated Contaminant Monitoring Rule 3 (estrone, 17-β-estradiol, 17-α-ethynylestradiol, 16-α-hydroxyestradiol (estriol), equilin, testosterone and 4-androstene-3,17-dione) were analyzed by liquid chromatography electrospray ionization tandem mass spectrometry (LC-ESI-MS/MS). Two analytical methods were compared: EPA method 539 and the isotope dilution method. EPA method 539 was successfully utilized in river and drinking water matrices with fortified recoveries of 98.9 to 108.5%. Samples from the Hillsborough River reflected levels below the method detection limit (MDL) for the majority of the analytes, except estrone (E1), which was detected at very low concentrations (<0.5 to 1 ng L(-1)) in the majority of samples. No hormones were detected in drinking water samples. The isotope dilution method was used to analyze reclaimed and aquifer storage and recovery (ASR) water samples as a result of strong matrix/solid phase extraction (SPE) losses observed in these more complex matrices. Most of the compounds were not detected or found at relatively low concentrations in the ASR samples. Attenuation of 50 to 99.1% was observed as a result of the ASR recharge/recovery cycles for most of the hormones, except for estriol (E3). Relatively stable concentrations of E3 were found, with only 10% attenuation at one of the sites and no measureable attenuation at another location. These results have substantiated that while EPA method 539 works well for most environmental samples, the isotope dilution method is more robust when dealing with complex matrices such as reclaimed and ASR samples.
Casson, Florence Boux de; Moal, Valérie; Gauchez, Anne-Sophie; Moineau, Marie-Pierre; Sault, Corinne; Schlageter, Marie-Hélène; Massart, Catherine
2017-04-01
The aim of this study was to evaluate the pre-analytical factors contributing to uncertainty in thyroglobulin measurement in fluids from fine-needle aspiration (FNA) washout of cervical lymph nodes. We studied pre-analytical stability, in different conditions, of 41 samples prepared with concentrated solutions of thyroglobulin (FNA washout or certified standard) diluted in physiological saline solution or buffer containing 6% albumin. In this buffer, over time, no changes in thyroglobulin concentrations were observed in all storage conditions tested. In albumin free saline solution, thyroglobulin recovery rates depended on initial sample concentrations and on modalities of their conservation (in conventional storage tubes, recovery mean was 56% after 3 hours-storage at room temperature and 19% after 24 hours-storage for concentrations ranged from 2 to 183 μg/L; recovery was 95%, after 3 hours or 24 hours-storage at room temperature, for a concentration of 5,656 μg/L). We show here that these results are due to non-specific adsorption of thyroglobulin in storage tubes, which depends on sample protein concentrations. We also show that possible contamination of fluids from FNA washout by plasma proteins do not always adequately prevent this adsorption. In conclusion, non-specific adsorption in storage tubes strongly contributes to uncertainty in thyroglobulin measurement in physiological saline solution. It is therefore recommended, for FNA washout, to use a buffer containing proteins provided by the laboratory.
Singh, U R; Enayat, M; White, S C; Wahl, P
2013-01-01
We report on the set-up and performance of a dilution-refrigerator based spectroscopic imaging scanning tunneling microscope. It operates at temperatures below 10 mK and in magnetic fields up to 14T. The system allows for sample transfer and in situ cleavage. We present first-results demonstrating atomic resolution and the multi-gap structure of the superconducting gap of NbSe(2) at base temperature. To determine the energy resolution of our system we have measured a normal metal/vacuum/superconductor tunneling junction consisting of an aluminum tip on a gold sample. Our system allows for continuous measurements at base temperature on time scales of up to ≈170 h.
Wang, Q; Yang, X; Leonard, S; Archbold, T; Sullivan, J A; Duncan, A M; Ma, W D L; Bizimungu, B; Murphy, A; Htoo, J K; Fan, M Z
2012-12-01
Whereas dietary fibers are well recognized for nutritional management of human health issues, fiber is also known to be one of the dietary factors potentially affecting digestive use of dietary proteins. As a staple food, potato (Solanum tuberosum) may be a significant dietary fiber source. The objective of this study was to examine effects of dietary supplementation of six potato cultivar-genotype samples that differ in soluble fiber content and two conventional fiber components (i.e., cellulose and guar gum) on the apparent ileal AA digestibility in pigs fed a high-fat basal diet. The basal diet was formulated as a zero-fiber negative control (NC) to contain 41.5% poultry meal, 4% casein, 15% animal fat-oil blend, 2.8% sucrose, 31% corn (Zea mays) starch, 0.50% salt, and 0.40% trace mineral-vitamin supplement with fat contributing to 47% of the dietary GE. The two fiber diets were formulated by respectively diluting the basal diet with 10% guar gum and 10% cellulose at the expense of corn starch. Six other test diets were formulated by including 8.5% guar gum and further diluting the basal diet with 25.1% one of the six cultivar-genotype samples of dehydrated potato tuber powder to contain about 10% total dietary fiber at the expense of corn starch. Eighty-one 25-kg barrows were fitted with a simple T-cannula at the distal ileum and fed the diets according to a completely randomized block design with each block lasting 28 d. Compared with the NC, the ileal digestibility of Ala, Gly, and Pro were decreased (P < 0.05) by 10% guar gum whereas the digestibility of Gly was reduced (P < 0.05) by 10% cellulose. The ileal digestibility of several AA was decreased (P < 0.05) by the test potatoes plus 8.5% guar gum compared with the NC. Our results suggest that dietary inclusion of fiber at 10% from guar gum and cellulose and contributed by potatoes may adversely affect digestive use of dietary protein.
Sedimentary control of volcanic debris-avalanche structures and transformation into lahars
NASA Astrophysics Data System (ADS)
Bernard, Karine; van Wyk de Vries, Benjamin; Thouret, Jean-Claude; Roche, Olivier; Samaniego Eguiguren, Pablo
2017-04-01
Volcanic debris avalanche structures and related transformations into lahars have been extensively analysed in order to establish a sedimentary classification of the deposits. Textural and structural variations of eight debris-avalanche deposits (DADs) have been correlated with Shape Preferred Orientation of 30,000 clasts together with grain-size distributions and statistical parameters from 156 sieved matrix samples. Granular segregation patterns have been observed with structural fault controls: proximal granular-segregation structures of the Tutupaca DAD ridges in Peru, basal sheared bands along overthrust lateral levee (Mt. Dore, France), mixing and cataclasis of fault-controlled deposits in half-graben during lateral spreading of distal thrust lobe (Pichu-Pichu, Peru), neo-cataclasis at the frontal thrust lobe (Meager, Canada and Mt. Dore, France). A logarithmic regression characterises the % matrix vs. matrix/gravels showing proximal and primary cataclasis, hybrid DADs with polymodal matrix and mixed facies up to transformations into lahar (Misti, Mt Dore). The sequential fragmentation helps to distinguish DAD that belong to Andean and Cascade Volcanic arcs (Tutupaca and Misti, Peru; Meager, Canada) to the hybrid DADs, before distal transformation into lahars (Pichu-Pichu); and hydrovolcanic fragmentation characterises the transformed lahar deposits (Misti). The fractal values of 150 sieved samples range between 2.3 and 2.7, implying extensional fractures with granular disaggregation. Skewness vs. kurtosis values help to distinguish the proximal mass wasting deposits and the transformed deposits by dilution. The sorting vs. median values enable us to differentiate the hybrid DADs with the transformed deposits by dilution. The sedimentological statistical parameters with Shape Preferred Orientation analysis that have been correlated with textural and structural observations show textural fabrics resulting from kinematic processes: cataclasis, hybrid matrix facies and transformations. Inherited fractures from tectono-volcanic structures contribute to the particle size distributions of DAD and associated deposits such as pyroclastic and lahar deposits (Misti, Mt Dore, Tutupaca). The statistical results highlight granular structure and kinematic process of DAD transformations into lahars and associated deposits, which would contribute to understand the rheological process behind the excess DAD run-out and to test granular models for DAD transformations. Key words: volcanic debris-avalanche deposits, lahar transformation, structure, sedimentology, hazard
NASA Astrophysics Data System (ADS)
Reda, Ahmed A.; Schnelle-Kreis, J.; Orasche, J.; Abbaszade, G.; Lintelmann, J.; Arteaga-Salas, J. M.; Stengel, B.; Rabe, R.; Harndorf, H.; Sippula, O.; Streibel, T.; Zimmermann, R.
2014-09-01
Gas phase emission samples of carbonyl compounds (CCs) were collected from a research ship diesel engine at Rostock University, Germany. The ship engine was operated using two different types of fuels, heavy fuel oil (HFO) and diesel fuel (DF). Sampling of CCs was performed from diluted exhaust using cartridges and impingers. Both sampling methods involved the derivatization of CCs with 2,4-Dinitrophenylhydrazine (DNPH). The CCs-hydrazone derivatives were analyzed by two analytical techniques: High Performance Liquid Chromatography-Diode Array Detector (HPLC-DAD) and Gas Chromatography-Selective Ion Monitoring-Mass Spectrometry (GC-SIM-MS). Analysis of DNPH cartridges by GC-SIM-MS method has resulted in the identification of 19 CCs in both fuel operations. These CCs include ten aliphatic aldehydes (formaldehyde, acetaldehyde, propanal, isobutanal, butanal, isopentanal, pentanal, hexanal, octanal, nonanal), three unsaturated aldehydes (acrolein, methacrolein, crotonaldehyde), three aromatic aldehyde (benzaldehyde, p-tolualdehyde, m,o-molualdehyde), two ketones (acetone, butanone) and one heterocyclic aldehyde (furfural). In general, all CCs under investigation were detected with higher emission factors in HFO than DF. The total carbonyl emission factor was determined and found to be 6050 and 2300 μg MJ-1 for the operation with HFO and DF respectively. Formaldehyde and acetaldehyde were found to be the dominant carbonyls in the gas phase of ship engine emission. Formaldehyde emissions factor varied from 3500 μg MJ-1 in HFO operation to 1540 μg MJ-1 in DF operation, which is 4-30 times higher than those of other carbonyls. Emission profile contribution of CCs showed also a different pattern between HFO and DF operation. The contribution of formaldehyde was found to be 58% of the emission profile of HFO and about 67% of the emission profile of DF. Acetaldehyde showed opposite behavior with higher contribution of 16% in HFO compared to 11% for DF. Heavier carbonyls (more than two carbon atoms) showed also more contribution in the emission profile of the HFO fuel (26%) than in DF (22%).
Joyce, Alison P; Wang, Mengmeng; Lawrence-Henderson, Rosemary; Filliettaz, Cynthia; Leung, Sheldon S; Xu, Xin; O'Hara, Denise M
2014-07-01
The purpose of this study was to validate the approach of serial sampling from one mouse through ligand binding assay (LBA) quantification of dosed biotherapeutic in diluted whole blood to derive a pharmacokinetic (PK) profile. This investigation compared PK parameters obtained using serial and composite sampling methods following administration of human IgG monoclonal antibody. The serial sampling technique was established by collecting 10 μL of blood via tail vein at each time point following drug administration. Blood was immediately diluted into buffer followed by analyte quantitation using Gyrolab to derive plasma concentrations. Additional studies were conducted to understand matrix and sampling site effects on drug concentrations. The drug concentration profiles, irrespective of biological matrix, and PK parameters using both sampling methods were not significantly different. There were no sampling site effects on drug concentration measurements except that concentrations were slightly lower in sodium citrated plasma than other matrices. We recommend the application of mouse serial sampling, particularly with limiting drug supply or specialized animal models. Overall the efficiencies gained by serial sampling were 40-80% savings in study cost, animal usage, study length and drug conservation while inter-subject variability across PK parameters was less than 30%.
Detection of Gastrointestinal Pathogens from Stool Samples on Hemoccult Cards by Multiplex PCR.
Alberer, Martin; Schlenker, Nicklas; Bauer, Malkin; Helfrich, Kerstin; Mengele, Carolin; Löscher, Thomas; Nothdurft, Hans Dieter; Bretzel, Gisela; Beissner, Marcus
2017-01-01
Purpose . Up to 30% of international travelers are affected by travelers' diarrhea (TD). Reliable data on the etiology of TD is lacking. Sufficient laboratory capacity at travel destinations is often unavailable and transporting conventional stool samples to the home country is inconvenient. We evaluated the use of Hemoccult cards for stool sampling combined with a multiplex PCR for the detection of model viral, bacterial, and protozoal TD pathogens. Methods . Following the creation of serial dilutions for each model pathogen, last positive dilution steps (LPDs) and thereof calculated last positive sample concentrations (LPCs) were compared between conventional stool samples and card samples. Furthermore, card samples were tested after a prolonged time interval simulating storage during a travel duration of up to 6 weeks. Results . The LPDs/LPCs were comparable to testing of conventional stool samples. After storage on Hemoccult cards, the recovery rate was 97.6% for C. jejuni , 100% for E . histolytica , 97.6% for norovirus GI, and 100% for GII. Detection of expected pathogens was possible at weekly intervals up to 42 days. Conclusion . Stool samples on Hemoccult cards stored at room temperature can be used in combination with a multiplex PCR as a reliable tool for testing of TD pathogens.
Surface contamination artificially elevates initial sweat mineral concentrations
USDA-ARS?s Scientific Manuscript database
During exercise in the heat, sweat is initially concentrated in minerals, but serial sweat samples appear more dilute. Possible causes include reduced dermal mineral concentrations or flushing of surface contamination. PURPOSE: To simultaneously sample mineral concentrations in transdermal fluid (T...
40 CFR 86.160-00 - Exhaust emission test procedure for SC03 emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... simulates testing in an environmental test cell (see § 86.162-00 (a) for a discussion of simulation... exhaust and dilution air bag samples to the analytical system and process the samples according to § 86...
Ingersoll, Christopher G.; Kunz, James L.; Hughes, Jamie P.; Wang, Ning; Ireland, D. Scott; Mount, David R.; Hockett, J. Russell; Valenti, Ted W
2015-01-01
The objective of the present study was to evaluate the relative sensitivity of test organisms in exposures to dilutions of a highly toxic sediment contaminated with metals and organic compounds. One dilution series was prepared using control sand (low total organic carbon [TOC; <0.1%, low binding capacity for contaminants]) and a second dilution series was prepared using control sediment from West Bearskin Lake, Minnesota, USA (high TOC [∼10% TOC, higher binding capacity for contaminants]). Test organisms included an amphipod (Hyalella azteca; 10-d and 28-d exposures), a midge (Chironomus dilutus; 20-d and 48-d exposures started with <1-h-old larvae, and 13-d and 48-d exposures started with 7-d-old larvae), and a unionid mussel (Lampsilis siliquoidea; 28-d exposures). Relative species sensitivity depended on the toxicity endpoint and the diluent. All 3 species were more sensitive in sand dilutions than in West Bearskin Lake sediment dilutions. The <1-h-old C. dilutus were more sensitive than 7-d-old C. dilutus, but replicate variability was high in exposures started with the younger midge larvae. Larval biomass and adult emergence endpoints of C. dilutus exhibited a similar sensitivity. Survival, weight, and biomass of H. azteca were more sensitive endpoints in 28-d exposures than in 10-d exposures. Weight and biomass of L. siliquoidea were sensitive endpoints in both sand and West Bearskin Lake sediment dilutions. Metals, ammonia, oil, and other organic contaminants may have contributed to the observed toxicity.
Murase, Tetsuma; Imaeda, Noriaki; Yamada, Hiroto; Takasu, Masaki; Taguchi, Kazuo; Katoh, Tsutomu
2010-06-01
The present study investigated whether substitution of HEPES for bicarbonate in BTS (BTS-H) used to dilute boar ejaculates immediately after ejaculation could reduce the increased inducibility of the acrosome reaction by calcium and calcium ionophore A23187. When an ejaculate was split, diluted 5-fold with regular BTS (BTS-B) and BTS-H and stored at 17 C for 12 h or 60 h, the extender or storage time had no significant influence on sperm motility or viability measured by the eosin-nigrosin method. When spermatozoa diluted serially with BTS-B and stored (36 h) were stimulated with Ca2+ (3 mM) and A23187 (0.3 microM), the proportion of spermatozoa that underwent the acrosome reaction (% acrosome reactions) significantly increased as the magnifications of dilution increased (bicarbonate content almost unchanged by dilution). By contrast, the % acrosome reactions in spermatozoa similarly diluted and stored with BTS-H decreased with the increasing magnifications of dilution (bicarbonate decreased). Sperm motility immediately after the end of incubation without A23178 tended to be lower for BTS-H than BTS-B, and the ejaculates for BTS-H had a tendency to have a lower total protein in seminal plasma than those for BTS-B. These results implied that the samples for BTS-H could be used as a model for ejaculates possibly collected during summer and showing subfertility. When an ejaculate was split, diluted serially with BTS-B and BTS-H and stored, viability measured by staining with propidium iodide was extremely similar between the 2 extenders and among the different dilution magnifications, regardless of whether spermatozoa were washed (stored for 36-66 h) or not (stored for 66-72 h). These results suggest that boar ejaculate can be stored with BTS-H at least according to the results for sperm motility and viability and that hypersensitivity of spermatozoa to Ca2+ and A23187 potentially associated with boar subfertility could be lessened by diluting ejaculates with BTS-H.
Preparation of Hemoglobin-Containing Microcapsules.
1981-06-01
were suspended in saline for storage in a refrigerator. Although in these microencapsulation experiments, the Hb was not denatured, the microcapsules ... microencapsulated Hb, l.O-ml sample of the microcapsule suspension was diluted with 10 ml 0.9% NaCI. The absorption spectrum was taken immediately after dilution...AD A135 634 PREPARATION OF HEMOGLOBIN CONTA NING MICROCAPSULES (U) I/ ,R 224 AM OS NTERNATIDNAL MENOPARKO CA REYES AUNN8 SRI-2254-1 DAMD17-80-C-01?7
Thermomechanical Processing of Structural Steels with Dilute Niobium Additions
NASA Astrophysics Data System (ADS)
Cui, Z.; Patel, J.; Palmiere, E. J.
The recrystallisation behaviour of medium carbon steels with dilute Nb addition was investigated by means of plane strain compression tests and the observation of prior austenite microstructures during different deformation conditions. It was found that complete suppression of recrystallisation did not occur in the deformation temperature range investigated. At lower deformation temperatures, partial recrystallisation occurred in the higher Nb sample. This gives the potential to obtain a full suppression of recrystallisation at lower deformation temperatures.
Riley, Paul W.; Gallea, Benoit; Valcour, Andre
2017-01-01
Background: Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay must be tested at additional dilutions to produce reportable results. Methods: The complexity of this process has motivated a large clinical reference laboratory to develop advanced computer algorithms with automated reflex testing rules to complete coagulation factor analysis. A method was developed for autoverification of coagulation factor activity using expert rules developed with on an off the shelf commercially available data manager system integrated into an automated coagulation platform. Results: Here, we present an approach allowing for the autoverification and reporting of factor activity results with greatly diminished technologist effort. Conclusions: To the best of our knowledge, this is the first report of its kind providing a detailed procedure for implementation of autoverification expert rules as applied to coagulation factor activity testing. Advantages of this system include ease of training for new operators, minimization of technologist time spent, reduction of staff fatigue, minimization of unnecessary reflex tests, optimization of turnaround time, and assurance of the consistency of the testing and reporting process. PMID:28706751
Riley, Paul W; Gallea, Benoit; Valcour, Andre
2017-01-01
Testing coagulation factor activities requires that multiple dilutions be assayed and analyzed to produce a single result. The slope of the line created by plotting measured factor concentration against sample dilution is evaluated to discern the presence of inhibitors giving rise to nonparallelism. Moreover, samples producing results on initial dilution falling outside the analytic measurement range of the assay must be tested at additional dilutions to produce reportable results. The complexity of this process has motivated a large clinical reference laboratory to develop advanced computer algorithms with automated reflex testing rules to complete coagulation factor analysis. A method was developed for autoverification of coagulation factor activity using expert rules developed with on an off the shelf commercially available data manager system integrated into an automated coagulation platform. Here, we present an approach allowing for the autoverification and reporting of factor activity results with greatly diminished technologist effort. To the best of our knowledge, this is the first report of its kind providing a detailed procedure for implementation of autoverification expert rules as applied to coagulation factor activity testing. Advantages of this system include ease of training for new operators, minimization of technologist time spent, reduction of staff fatigue, minimization of unnecessary reflex tests, optimization of turnaround time, and assurance of the consistency of the testing and reporting process.
The hook effect in calcitonin immunoradiometric assay: a case report.
Fangous, Marie-Sarah; Kerspern, Hélène; Moineau, Marie-Pierre; Kerlan, Véronique; Alavi, Zarrin; Carré, Jean-Luc
2012-12-01
The hook effect, which has long been detected and documented for immunoradiometric assays (IRMA) such as those measuring prolactin or thyroglobulin, occurs when the serum antigen level is extremely high, thus inducing a bias in the methodology of measurement. We report the case of an 80-year-old man with confirmed medullary thyroid carcinoma (MTC). In the case reported here, the clinical status of the patient contrasts with his tumor antigen, serum calcitonin (CT), concentrations. The measured increased CT concentrations revealed the presence of a hook effect. This phenomenon occurs due to an excess of antigen during the one-step IRMA where the signal antibodies, bound to the non-captured antigens, are washed out during the measurement, inducing the loss of signal. Aiming to prevent the "hook effect", successive dilutions of the same sample of serum were done. Previous studies have shown when one-step IRMA reveals high concentrations of a tumor serum antigen (i.e. prolactin or thyroglobulin), a two-step IRMA or a systematic 1:10 dilution of the serum sample prevents the formation of the "hook effect". In our case report, the CT "hook effect" formation was prevented by performing serial dilutions of the serum sample. Copyright © 2012 Elsevier Masson SAS. All rights reserved.
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Pump—Constant Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CVS sample probes and/or a heat exchanger or electronic flow... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Pump—Constant Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CVS sample probes and/or a heat exchanger or electronic flow... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 91.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Pump—Constant Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CVS sample probes and/or a heat exchanger or electronic flow... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Volume Sampler (PDP-CVS) system with a heat exchanger, or a Critical Flow Venturi—Constant Volume Sampler (CFV-CVS) system with CFV sample probes and/or a heat exchanger or electronic flow compensation. Figure... sampling point. (ii) For the CFV-CVS, either a heat exchanger or electronic flow compensation is required...
The effects of sewage discharge on water quality and phytoplankton of Hawai'ian coastal waters.
Parnell, P Ed
2003-05-01
The effects of sewage discharge on algal populations and the quality of Hawai'ian coastal waters were investigated. Two outfalls were studied. One discharges primary treated sewage and the other discharges secondary treated sewage but are otherwise similar. This enabled comparisons of the effects of these different levels of treatment on the water quality and algal productivity of receiving waters. Plumes were followed and repeatedly sampled in a time-series manner. Rhodamine dye was used as a conservative tracer to compare the dilution behavior of the plume constituents MRP, NO(3)+NO(2), NH(4), Silicate, TDP, TDN, total bacteria, PC, and PN. Rates of initial dilution ranged from two to almost three orders of magnitude, and were in reasonable agreement with engineering model predictions. Dilution of plume constituents approximated that of Rhodamine until background concentrations were reached, typically within 10 min of discharge. Chl a concentrations did not increase through time in the primary sewage plume but did increase up to 30% in the secondary sewage plume. However, rates of far-field dilution were so rapid that the increase could not have been due to algal growth. The increase was attributed to the plume mixing with a water mass whose relative chl a concentrations were greater. Rates of secondary dilution ranged from 2 to 3 orders of magnitude resulting in total dilutions of 10(5)-10(6) within 3 h of discharge. These rates of secondary dilution were much greater than model predictions. From a nutrient standpoint, secondary treatment exhibited no advantages over primary treatment because dilutions were so rapid. Copyright 2002 Elsevier Science B.V.
Diurnal trends in coarse particulate matter composition in the Los Angeles Basin.
Cheung, Kalam; Daher, Nancy; Shafer, Martin M; Ning, Zhi; Schauer, James J; Sioutas, Constantinos
2011-11-01
To investigate the diurnal profile of the concentration and composition of ambient coarse particles, three sampling sites were set up in the Los Angeles Basin to collect coarse particulate matter (CPM) in four different time periods of the day (morning, midday, afternoon and overnight) in summer and winter. The samples were analyzed for total and water-soluble elements, inorganic ions and water-soluble organic carbon (WSOC). In summer, highest concentrations of CPM gravimetric mass, mineral and road dust, and WSOC were observed in midday and afternoon, when the prevailing onshore wind was stronger. In general, atmospheric dilution was lower in winter, contributing to the accumulation of air pollutants during stagnation conditions. Turbulences induced by traffic become a significant particle re-suspension mechanism, particularly during winter night time, when mixing height was lowest. This is evident by the high levels of CPM mass, mineral and road dust in winter overnight at the near-freeway sites located in urban Los Angeles, and to a lesser extent in Riverside. WSOC levels were higher in summer, with a similar diurnal profile with mineral and road dust, indicating that they either share common sources, or that WSOC may be adsorbed or absorbed onto the surfaces of these dust particles. In general, the contribution of inorganic ions to CPM mass was greater in the overnight sampling period at all sampling sites, suggesting that the prevailing meteorological conditions (lower temperature and higher relative humidity) favor the formation of these ions in the coarse mode. Nitrate, the most abundant CPM-bound inorganic species in this basin, is found to be predominantly formed by reactions with sea salt particles in summer. When the sea salt concentrations were low, the reaction with mineral dust particles and the condensation of ammonium nitrate on CPM surfaces also contributes to the formation of nitrate in the coarse mode.
NASA Astrophysics Data System (ADS)
Gus'kov, V. Yu.; Ganieva, A. G.; Kudasheva, F. Kh.
2016-11-01
The sorption of organic molecules on the surfaces of a number of adsorbents based on a microporous copolymer of styrene and divinylbenzene modified with different quantities of uracil is studied by means of inverse gas chromatography at infinite dilution. Samples containing 10-6, 10-5, 10-4, 10-3, 10-2, and 0.5 × 10‒1 weight parts of uracil (the pC of uracil ranges from 1.3 to 6) are studied. The contributions from different intermolecular interactions to the Helmholtz energy of sorption are calculated via the linear free energy relationship. It is found that as the concentration of uracil on the surface of the polymer adsorbent grows, the contributions from different intermolecular interactions and the conventional polarity of the surface have a bend at pC = 3, due probably to the formation of a supramolecular structure of uracil. Based on the obtained results, it is concluded that the formation of the supramolecular structure of uracil on the surface of the polymer adsorbent starts when pC < 3.
NASA Astrophysics Data System (ADS)
Sargent, S.; Somers, J. M.
2015-12-01
Trace-gas eddy covariance flux measurement can be made with open-path or closed-path analyzers. Traditional closed-path trace-gas analyzers use multipass absorption cells that behave as mixing volumes, requiring high sample flow rates to achieve useful frequency response. The high sample flow rate and the need to keep the multipass cell extremely clean dictates the use of a fine-pore filter that may clog quickly. A large-capacity filter cannot be used because it would degrade the EC system frequency response. The high flow rate also requires a powerful vacuum pump, which will typically consume on the order of 1000 W. The analyzer must measure water vapor for spectroscopic and dilution corrections. Open-path analyzers are available for methane, but not for nitrous oxide. The currently available methane analyzers have low power consumption, but are very large. Their large size degrades frequency response and disturbs the air flow near the sonic anemometer. They require significant maintenance to keep the exposed multipass optical surfaces clean. Water vapor measurements for dilution and spectroscopic corrections require a separate water vapor analyzer. A new closed-path eddy covariance system for measuring nitrous oxide or methane fluxes provides an elegant solution. The analyzer (TGA200A, Campbell Scientific, Inc.) uses a thermoelectrically-cooled interband cascade laser. Its small sample-cell volume and unique sample-cell configuration (200 ml, 1.5 m single pass) provide excellent frequency response with a low-power scroll pump (240 W). A new single-tube Nafion® dryer removes most of the water vapor, and attenuates fluctuations in the residual water vapor. Finally, a vortex intake assembly eliminates the need for an intake filter without adding volume that would degrade system frequency response. Laboratory testing shows the system attenuates the water vapor dilution term by more than 99% and achieves a half-power band width of 3.5 Hz.
IDENTIFYING POTENTIAL SOURCES OF BACKGROUND CONTAMINATION IN RT-PCR
Extraction of nucleic acids from low biomass samples, such as drinking water, is particularly sensitive to potential background contamination because the contaminating material is minimally diluted by the sample. The presence of bacterial DNA in Taq DNA polymerase is wel...
Robotics in the Laboratory: A Generic Approach.
ERIC Educational Resources Information Center
Sharp, Robert L.; And Others
1988-01-01
Discusses the use of robotics in the analytical chemistry laboratory. Suggests using a modular setup to best use robots and laboratory space. Proposes a sample preparation system which can perform aliquot measurement, dilution, mixing, separation, and sample transfer. Recognizes attributes and shortcomings. (ML)
Bouacha, Mabrouka; Ayed, Hayette; Grara, Nedjoud
2018-04-13
Medicinal benefits of honey bee have been recognized in the medical community since ancient times as a remedy for many diseases and infections. This study aimed to investigate the in vitro susceptibility of 11 multidrug-resistant bacterial strains, isolated from urinary tract infections of pregnant women, to six honey samples collected from different localities in the east of Algeria. The evaluation of the antibacterial activity was performed by the well method followed by the broth dilution method using two-fold dilutions of each honey sample ranging from 2.5 to 80% (w/v). The results obtained in this study revealed that all tested honeys exhibited potent antibacterial activity against the tested strains. The diameters of inhibition ranged from 19.67 to 53.33 mm, with minimum inhibitory concentrations (MICs) ranging from 2.5 to 40% (w/v) and minimum bactericidal concentration (MBCs) varied between 2.5 and 80% (w/v). Gram-positive bacteria were found to be more susceptible than Gram-negative bacteria with diameters ranging from 43.33 to 53.33 mm; MIC and MBC values ranged from 2.5 to 5% (w/v). The P.aeruginosa strain was found to be less susceptible than other strains with inhibitory diameters ranging from 19.67 to 27.33 mm; MICs ranged from 20 to 40% and MBCs ranged from 20 to 80% ( w/v ). This contribution has provided a broad overview of the antibacterial activity of Algerian honey and shown that honey bee has great potential for therapeutic use as an alternative therapy for urinary tract infection treatment which is safe and efficient during pregnancy.
Salinas-Mélendez, J A; Galván de la Garza, S; Riojas-Valdés, V M; Wong González, A; Avalos-Ramírez, R
2001-01-01
The aim of the present study was to determine the presence of Borrelia burgdorferi antibodies in horses from the metropolitan area of Monterrey, Nuevo León, México. Blood serum was obtained from a total of 100 horses residing at different counties in the area. From each animal data was obtained on age, sex, county of residence, presence of ectoparasites and clinical signs. All sera samples were analyzed by indirect immunofluoresence and the sera that resulted positive to this test was analyzed by Western blot. The serological test yielded 34 positive sera at 1:64 dilution, and from them 6 were positive at 1:128 dilution, 3 at 1:256, and only one at 1:512. Confirmation of the infection by Western blot was obtained only in the sample positive at the 1:512 dilution. These results shown a low frequency of seropositivity to B. burgdorferi of the horses in the area, confirming previous studies indicating that in northeast Mexico Lyme disease is present in different animal species.
Chang, Chih-Chun; Su, Ming-Jang; Ho, Jung-Li; Tsai, Yu-Hui; Tsai, Wei-Ting; Lee, Shu-Jene; Yen, Tzung-Hai; Chu, Fang-Yeh
2016-01-01
Urine protein detection could be underestimated using the conventional dipstick method because of variations in urine aliquots. This study aimed to assess the efficacy of the semi-quantitative urine protein-to-creatinine (P/C) ratio compared with other laboratory methods. Random urine samples were requested from patients undergoing chronic kidney disease screening. Significant proteinuria was determined by the quantitative P/C ratio of at least 150 mg protein/g creatinine. The semi-quantitative P/C ratio, dipstick protein and quantitative protein concentrations were compared and analyzed. In the 2932 urine aliquots, 156 (5.3 %) urine samples were considered as diluted and 60 (39.2 %) were found as significant proteinuria. The semi-quantitative P/C ratio testing had the best sensitivity (70.0 %) and specificity (95.9 %) as well as the lowest underestimation rate (0.37 %) when compared to other laboratory methods in the study. In the semi-quantitative P/C ratio test, 19 (12.2 %) had positive, 52 (33.3 %) had diluted, and 85 (54.5 %) had negative results. Of those with positive results, 7 (36.8 %) were positive detected by traditional dipstick urine protein test, and 9 (47.4 %) were positive detected by quantitative urine protein test. Additionally, of those with diluted results, 25 (48.1 %) had significant proteinuria, and all were assigned as no significant proteinuria by both tests. The semi-quantitative urine P/C ratio is clinically applicable based on its better sensitivity and screening ability for significant proteinuria than other laboratory methods, particularly in diluted urine samples. To establish an effective strategy for CKD prevention, urine protein screening with semi-quantitative P/C ratio could be considered.
Urine osmolality in the US population: Implications for environmental biomonitoring
Yeh, Hung-Chieh; Lin, Yu-Sheng; Kuo, Chin-Chi; Weidemann, Darcy; Weaver, Virginia; Fadrowski, Jeffrey; Neu, Alicia; Navas-Acien, Ana
2018-01-01
Background For many environmental chemicals, concentrations in spot urine samples are considered valid surrogates of exposure and internal dose. To correct for urine dilution, spot urine concentrations are commonly adjusted for urinary creatinine. There are, however, several concerns about the use of urine creatinine. While urine osmolality is an attractive alternative; its characteristics and determinants in the general population remain unknown. Our objective was to describe the determinants of urine osmolality and to contrast the difference between osmolality and creatinine in urine. Methods From the National Health and Nutrition Examination Survey (NHANES) 2009–2012, 10,769 participants aged 16 years or older with measured urine osmolality and creatinine were used in the analysis. Very dilute and very concentrated urine was defined as urine creatinine lower than 0.3 g/l and higher than 3 g/l, respectively. Linear and logistic regression analyses were performed to investigate the associations of interest. Results Urine osmolality and creatinine were highly correlated (Pearson correlation coefficient = 0.75) and their respective median values were 648 mOsm/kg and 1.07 g/l. The prevalence of very dilute and very concentrated urine samples was 8.1% and 3.1%, respectively. Factors associated in the same direction with both urine osmolality and urine creatinine included age, sex, race, body mass index (BMI), hypertension, water intake, and blood osmolality. The magnitude of associations expressed as percent change was significantly stronger with creatinine than osmolality. Compared to urine creatinine, urine osmolality did not vary by diabetes status but was affected by daily total protein intake. Participants with chronic kidney disease (CKD) had significantly higher urine creatinine concentrations but lower urine osmolality. Both very dilute and concentrated urine were associated with a diverse array of sociodemographic, medical conditions, and dietary factors. For instance, females were approximately 3.3 times more likely to have urine over-dilution than male [the adjusted odds ratios (95% CI) = 3.27 (2.10–5.10)]. Conclusion Although the determinants of urine osmolality were generally similar to those of urine creatinine, the relative influence of socio-demographic and medical conditions was less on urine osmolality than on urine creatinine. Protocols for spot urine sample collection could recommend avoiding excessive and insufficient water intake before urine sampling to improve urine adequacy. The feasibility of adopting urine osmolality adjustment and water intake recommendations before providing spot urine samples for environmental biomonitoring merits further investigation. PMID:25460670
Detection of Toxoplasma oocysts from soil by modified sucrose flotation and PCR methods.
Matsuo, Junji; Kimura, Daisuke; Rai, Shiba Kumar; Uga, Shoji
2004-06-01
A detection method of Toxoplasma gondii oocysts from soil was evaluated using the sucrose flotation technique with modification involving addition of 0.1% gelatin into washing and floating solutions. PCR was performed on untreated samples and after treatment with polyvinylpyrrolidone (PVP), heating and cooling, and NaCl. The addition of gelatin in the sucrose solution yielded a higher number of oocysts. A very thin band was observed when DNA extract was diluted to 1:1024, indicating the presence of PCR inhibitor in the soil. PCR performed on untreated DNA, on PVP-treated, and on PVP-treated with heating and cooling without added bovine serum albumin (BSA) showed a band only at higher dilutions (1:1024 and 1:512) but at a much lower dilution (1:8) with BSA. In contrast, DNA treated with all three agents showed a band at a much lower dilution (1:64), even without added BSA, and no dilution was required when BSA was added. The PCR inhibitors present in the soil were removed by employing various treatment procedures during DNA extraction, and BSA in PCR. Furthermore, the detection limit with the method was 1 oocyst/g of soil, indicating that this method is useful in epidemiological studies.
Sediment toxicity test results for the Urban Waters Study 2010, Bellingham Bay, Washington
Biedenbach, James M.
2011-01-01
The Washington Department of Ecology annually determines the quality of recently deposited sediments in Puget Sound as a part of Ecology's Urban Waters Initiative. The annual sediment quality studies use the Sediment Quality Triad (SQT) approach, thus relying on measures of chemical contamination, toxicity, and benthic in-faunal effects (Chapman, 1990). Since 2002, the studies followed a rotating sampling scheme, each year sampling a different region of the greater Puget Sound Basin. During the annual studies, samples are collected in locations selected with a stratified-random design, patterned after the designs previously used in baseline surveys completed during 1997-1999 (Long and others, 2003; Wilson and Partridge, 2007). Sediment samples were collected by personnel from the Washington Department of Ecology, in June of 2010 and shipped to the U. S. Geological Survey (USGS) laboratory in Corpus Christi, Texas (not shown), where the tests were performed. Sediment pore water was extracted with a pneumatic apparatus and was stored frozen. Just before testing, water-quality measurements were made and salinity adjusted, if necessary. Tests were performed on a dilution series of each sample consisting of 100-, 50-, and 25-percent pore-water concentrations. The specific objectives of this study were to: * Extract sediment pore water from a total of 30 sediment samples from the Bellingham Bay, Washington area within a day of receipt of the samples. * Measure water-quality parameters (salinity, dissolved oxygen, pH, sulfide, and ammonia) of thawed pore-water samples before testing and adjust salinity, temperature and dissolved oxygen, if necessary, to obtain optimal ranges for the test species. * Conduct the fertilization toxicity test with pore water using sea urchin (Stronylocentrotus purpuratus) (S. purpuratus) gametes. * Perform quality control assays with reference pore water, dilution blanks and a positive control dilution series with sodium dodecyl sulfate (SDS) in conjunction with each test. * Determine which samples caused a significant decrease in percent fertilization success relative to the negative control.
Greenspoon, S A; Sykes, K L V; Ban, J D; Pollard, A; Baisden, M; Farr, M; Graham, N; Collins, B L; Green, M M; Christenson, C C
2006-12-20
Human genome, pharmaceutical and research laboratories have long enjoyed the application of robotics to performing repetitive laboratory tasks. However, the utilization of robotics in forensic laboratories for processing casework samples is relatively new and poses particular challenges. Since the quantity and quality (a mixture versus a single source sample, the level of degradation, the presence of PCR inhibitors) of the DNA contained within a casework sample is unknown, particular attention must be paid to procedural susceptibility to contamination, as well as DNA yield, especially as it pertains to samples with little biological material. The Virginia Department of Forensic Science (VDFS) has successfully automated forensic casework DNA extraction utilizing the DNA IQ(trade mark) System in conjunction with the Biomek 2000 Automation Workstation. Human DNA quantitation is also performed in a near complete automated fashion utilizing the AluQuant Human DNA Quantitation System and the Biomek 2000 Automation Workstation. Recently, the PCR setup for casework samples has been automated, employing the Biomek 2000 Automation Workstation and Normalization Wizard, Genetic Identity version, which utilizes the quantitation data, imported into the software, to create a customized automated method for DNA dilution, unique to that plate of DNA samples. The PCR Setup software method, used in conjunction with the Normalization Wizard method and written for the Biomek 2000, functions to mix the diluted DNA samples, transfer the PCR master mix, and transfer the diluted DNA samples to PCR amplification tubes. Once the process is complete, the DNA extracts, still on the deck of the robot in PCR amplification strip tubes, are transferred to pre-labeled 1.5 mL tubes for long-term storage using an automated method. The automation of these steps in the process of forensic DNA casework analysis has been accomplished by performing extensive optimization, validation and testing of the software methods.
Planas, Carles; Palacios, Oscar; Ventura, Francesc; Rivera, Josep; Caixach, Josep
2008-08-15
A method based on automated solid-phase extraction (SPE) and isotope dilution gas chromatography/high resolution mass spectrometry (GC/HRMS) has been developed for the analysis of nine nitrosamines in water samples. The combination of automated SPE and GC/HRMS for the analysis of nitrosamines has not been reported previously. The method shows as advantages the selectivity and sensitivity of GC/HRMS analysis and the high efficiency of automated SPE with coconut charcoal EPA 521 cartridges. Low method detection limits (MDLs) were achieved, along with a greater facility of the procedure and less dependence on the operator with regard to the methods based on manual SPE. Quality requirements for isotope dilution-based methods were accomplished for most analysed nitrosamines, regarding to trueness (80-120%), method precision (<15%) and MDLs (0.08-1.7 ng/L). Nineteen water samples (16 samples from a drinking water treatment plant {DWTP}, 2 chlorinated samples from a sewage treatment plant {STP} effluent, and 1 chlorinated sample from a reservoir) were analysed. Concentrations of nitrosamines in the STP effluent were 309.4 and 730.2 ng/L, being higher when higher doses of chlorine were applied. N-Nitrosodimethylamine (NDMA) and N-nitrosodiethylamine (NDEA) were the main compounds identified in the STP effluent, and NDEA was detected above 200 ng/L, regulatory level for NDMA in effluents stated in Ontario (Canada). Lower concentrations of nitrosamines were found in the reservoir (20.3 ng/L) and in the DWTP samples (n.d. -28.6 ng/L). NDMA and NDEA were respectively found in the reservoir and in treated and highly chlorinated DWTP samples at concentrations above 10 ng/L (guide value established in different countries). The highest concentrations of nitrosamines were found after chlorination and ozonation processes (ozonated, treated and highly chlorinated water) in DWTP samples.
Heishima, Yasuhiro; Hori, Yasutomo; Chikazawa, Seishiro; Kanai, Kazutaka; Hoshi, Fumio; Itoh, Naoyuki
2016-08-01
OBJECTIVE To investigate the in vitro stability of atrial natriuretic peptide (ANP) in plasma samples under various storage conditions and the influence of anesthesia on plasma ANP concentration in cats. ANIMALS 1 cat with congestive heart failure and 5 healthy adult mixed-breed cats. PROCEDURES A plasma sample from the cat with heart failure was serially diluted, and dilutional parallelism of ANP concentration was evaluated. Plasma samples containing aprotinin or serum samples from the 5 healthy cats were kept at room temperature (27°C) for ≤ 12 hours. Plasma samples from the same healthy cats were stored at -70°, -20°, or 4°C for ≤ 14 days. Plasma samples were obtained from the healthy cats before and during isoflurane anesthesia. Plasma ANP concentrations were measured at a commercial laboratory by use of a human ANP chemiluminescence assay. RESULTS Intra- and interassay coefficients of variation were 1.5% and 2.5%, respectively, and dilutional parallelism was established. Although ANP concentration decreased by 82.4 ± 13.6% (mean ± SD) after sample storage for 12 hours at room temperature, this decrease was prevented by aprotinin. Plasma ANP concentrations were stable for 7 days at -20°C and for 14 days at -70°C. However, concentrations decreased markedly to 57.6 ± 6.9% at -20°C and to 18.0 ± 3.0% at 4°C after 14 days. Plasma ANP concentration decreased significantly in cats during anesthesia and was correlated with blood pressure. CONCLUSIONS AND CLINICAL RELEVANCE Results suggested that aprotinin should be added routinely in preparation of plasma samples from cats for measurement of ANP concentration, and those samples, if stored, should be frozen immediately at ≤ -20°C. General anesthesia or systemic blood pressure may affect plasma ANP concentration in cats.
NASA Astrophysics Data System (ADS)
Niu, Q.; Zhang, C.
2017-12-01
Archie's law is an important empirical relationship linking the electrical resistivity of geological materials to their porosity. It has been found experimentally that the porosity exponent m in Archie's law in sedimentary rocks might be related to the degree of cementation, and therefore m is termed as "cementation factor" in most literatures. Despite it has been known for many years, there is lack of well-accepted physical interpretations of the porosity exponent. Some theoretical and experimental evidences have also shown that m may be controlled by the particle and/or pore shape. In this study, we conduct a pore-scale modeling of the porosity exponent that incorporates different geological processes. The evolution of m of eight synthetic samples with different particle sizes and shapes are calculated during two geological processes, i.e., compaction and cementation. The numerical results show that in dilute conditions, m is controlled by the particle shape. As the samples deviate from dilute conditions, m increases gradually due to the strong interaction between particles. When the samples are at static equilibrium, m is noticeably larger than its values at dilution condition. The numerical simulation results also show that both geological compaction and cementation induce a significant increase in m. In addition, the geometric characteristics of these samples (e.g., pore space/throat size, and their distributions) during compaction and cementation are also calculated. Preliminary analysis shows a unique correlation between the pore size broadness and porosity exponent for all eight samples. However, such a correlation is not found between m and other geometric characteristics.
Delgado-Povedano, M M; Calderón-Santiago, M; Priego-Capote, F; Luque de Castro, M D
2016-01-01
The determination of physiological levels of amino acids is important to aid in the diagnosis and treatment of several diseases and nutritional status of individuals. Amino acids are frequently determined in biofluids such as blood (serum or plasma) and urine; however, there are less common biofluids with different concentration profiles of amino acids that could be of interest. One of these biofluids is sweat that can be obtained in a non-invasive manner and is characterized by low complex composition. The analysis of amino acids in human sweat requires the development of sample preparation strategies according to the sample matrix and small collected volume. The influence of sample preparation on the quantitative analysis of amino acids in sweat by LC-MS/MS has been assessed through a comparison between two strategies: dilution of sweat and centrifugal microsolid-phase extraction (c-μSPE). In both cases, several dilution factors were assayed for in-depth knowledge of the matrix effects, and the use of c-μSPE provided the best results in terms of accuracy. The behavior of the target analytes was a function of the dilution factor, thus providing a pattern for sample preparation that depended on the amino acid to be determined. The concentration of amino acids in sweat ranges between 6.20 ng mL(-1) (for homocysteine) and 259.77 µg mL(-1) (for serine) with precision, expressed as relative standard deviation, within 1.1-21.4%. Copyright © 2015 Elsevier B.V. All rights reserved.
Quantifying Sulfur-Containing Compounds Over the Santa Barbara Channel
NASA Astrophysics Data System (ADS)
Black, J.; Hughes, S.; Blake, D. R.
2016-12-01
Carbonyl sulfide (OCS) is emitted to the atmosphere through the outgassing of ocean surface waters. OCS is also the primary source of sulfur-containing compounds in the stratosphere and contributes to the formation of the stratospheric sulfate layer. During the 2016 Student Airborne Research Program (SARP), whole air samples were collected on the NASA DC-8 aircraft over the Santa Barbara Channel. Five additional surface samples were taken at various locations along the Santa Barbara Channel. The samples were analyzed using gas chromatography in the Rowland-Blake lab at UC Irvine, and compounds such as OCS, dimethyl sulfide (DMS), carbon disulfide (CS2), bromoform (CHBr3), and methyl iodide (CH3I) associated with ocean emissions and stratospheric aerosols were analyzed. These marine sourced compounds, excluding OCS, showed expected trends of dilution with increasing altitude. The surface samples from the Santa Barbara Channel all exhibited elevated concentrations of OCS in comparison to samples taken from the aircraft, with an average of 666 ± 12 pptv, whereas the average background concentration of OCS was 587 ± 19 pptv. SARP flights from 2009-2015 over the Santa Barbara Channel saw an average OCS concentration of 548 ± 26 pptv. Elevated levels of OCS have never been detected from the aircraft during SARP flights, indicating that OCS emissions must be measured using surface sampling if emission estimates from the ocean are to be evaluated.
Davis, William E; Li, Yongtao
2008-07-15
A new isotope dilution gas chromatography/chemical ionization/tandem mass spectrometric method was developed for the analysis of carcinogenic hydrazine in drinking water. The sample preparation was performed by using the optimized derivatization and multiple liquid-liquid extraction techniques. Using the direct aqueous-phase derivatization with acetone, hydrazine and isotopically labeled hydrazine-(15)N2 used as the surrogate standard formed acetone azine and acetone azine-(15)N2, respectively. These derivatives were then extracted with dichloromethane. Prior to analysis using methanol as the chemical ionization reagent gas, the extract was dried with anhydrous sodium sulfate, concentrated through evaporation, and then fortified with isotopically labeled N-nitrosodimethylamine-d6 used as the internal standard to quantify the extracted acetone azine-(15)N2. The extracted acetone azine was quantified against the extracted acetone azine-(15)N2. The isotope dilution standard calibration curve resulted in a linear regression correlation coefficient (R) of 0.999. The obtained method detection limit was 0.70 ng/L for hydrazine in reagent water samples, fortified at a concentration of 1.0 ng/L. For reagent water samples fortified at a concentration of 20.0 ng/L, the mean recoveries were 102% with a relative standard deviation of 13.7% for hydrazine and 106% with a relative standard deviation of 12.5% for hydrazine-(15)N2. Hydrazine at 0.5-2.6 ng/L was detected in 7 out of 13 chloraminated drinking water samples but was not detected in the rest of the chloraminated drinking water samples and the studied chlorinated drinking water sample.
Heilmann, Jens; Boulyga, Sergei F; Heumann, Klaus G
2004-09-01
Inductively coupled plasma isotope-dilution mass spectrometry (ICP-IDMS) with direct injection of isotope-diluted samples into the plasma, using a direct injection high-efficiency nebulizer (DIHEN), was applied for accurate sulfur determinations in sulfur-free premium gasoline, gas oil, diesel fuel, and heating oil. For direct injection a micro-emulsion consisting of the corresponding organic sample and an aqueous 34S-enriched spike solution with additions of tetrahydronaphthalene and Triton X-100, was prepared. The ICP-MS parameters were optimized with respect to high sulfur ion intensities, low mass-bias values, and high precision of 32S/34S ratio measurements. For validation of the DIHEN-ICP-IDMS method two certified gas oil reference materials (BCR 107 and BCR 672) were analyzed. For comparison a wet-chemical ICP-IDMS method was applied with microwave-assisted digestion using decomposition of samples in a closed quartz vessel inserted into a normal microwave system. The results from both ICP-IDMS methods agree well with the certified values of the reference materials and also with each other for analyses of other samples. However, the standard deviation of DIHEN-ICP-IDMS was about a factor of two higher (5-6% RSD at concentration levels above 100 mircog g(-1)) compared with those of wet-chemical ICP-IDMS, mainly due to inhomogeneities of the micro-emulsion, which causes additional plasma instabilities. Detection limits of 4 and 18 microg g(-1) were obtained for ICP-IDMS in connection with microwave-assisted digestion and DIHEN-ICP-IDMS, respectively, with a sulfur background of the used Milli-Q water as the main limiting factor for both methods.
Role of valence electrons in phase transformation kinetics of thallium and its dilute alloys
NASA Technical Reports Server (NTRS)
Ahmed, R.; Ahmed, S.
1991-01-01
The kinetics of the phase transformation of thallium and its dilute alloys were investigated using XRD and calorimetry. Pure thallium exhibits a beta(bcc) to alpha(hcp) phase transformation on cooling at 508 K. With alloying additions, the crystal structure for each phase does not change, although the size of the unit cell increases. The enthalpy and the temperature of phase transformation of each alloy have been determined. The chemical free energy change associated with the phase transformation of each alloy was calculated. The valence electrons make an outstanding contribution to the chemical free energy change required for the phase change.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, W.; Chen, X.; Tucker, M.
2012-01-01
The degree of polymerization(DP) of cellulose is considered to be one of the most important properties affecting the enzymatic hydrolysis of cellulose. Various pure cellulosic and biomass materials have been used in a study of the effect of dilute acid treatment on cellulose DP. A substantial reduction in DP was found for all pure cellulosic materials studied even at conditions that would be considered relatively mild for pretreatment. The effect of dilute acid pretreatment on cellulose DP in biomass samples was also investigated. Corn stover pretreated with dilute acid under the most optimal conditions contained cellulose with a DPw inmore » the range of 1600{approx}3500, which is much higher than the level-off DP(DPw 150{approx}300) obtained with pure celluloses. The effect of DP reduction on the saccharification of celluloses was also studied. From this study it does not appear that cellulose DP is a main factor affecting cellulose saccharification.« less
NASA Astrophysics Data System (ADS)
van der Heijden, Gregory; Legout, Arnaud; Mareschal, Louis; Ranger, Jacques; Dambrine, Etienne
2017-07-01
In terrestrial ecosystems, plant-available pools of magnesium and calcium are assumed to be stored in the soil as exchangeable cations adsorbed on the surface of mineral and/or organic particles. The pools of exchangeable magnesium and calcium are measured by ion-exchange soil extractions. These pools are sustained in the long term by the weathering of primary minerals in the soil and atmospheric inputs. This conceptual model is the base of input-output budgets from which soil acidification and the sustainability of soil chemical fertility is inferred. However, this model has been questioned by data from long-term forest ecosystem monitoring sites, particularly for calcium. Quantifying the contribution of atmospheric inputs, ion exchange and weathering of both primary, secondary and non-crystalline phases to tree nutrition in the short term is challenging. In this study, we developed and applied a novel isotopic dilution technique using the stable isotopes of magnesium and calcium to study the contribution of the different soil phases to soil solution chemistry in a very acidic soil. The labile pools of Mg and Ca in the soil (pools in equilibrium with the soil solution) were isotopically labeled by spraying a solution enriched in 26Mg and 44Ca on the soil. Labeled soil columns were then percolated with a dilute acid solution during a 3-month period and the isotopic dilution of the tracers was monitored in the leaching solution, in the exchangeable (2 sequential 1 mol L-1 ammonium acetate extractions) and non-crystalline (2 sequential soil digestions: oxalic acid followed by nitric acid) phases. Significant amounts of Mg and Ca isotope tracer were recovered in the non-crystalline soil phases. These phases represented from 5% to 25% and from 24% to 50%, respectively, of the Mg and Ca labile pools during the experiment. Our results show that non-crystalline phases act as both a source and a sink of calcium and magnesium in the soil, and contribute directly to soil solution chemistry on very short-term time scales. These phases are very abundant in acid soils and, in the present study, represent a substantial calcium pool (equivalent in size to the Ca exchangeable pool). The gradual isotopic dilution of Mg and Ca isotope ratios in the leaching solution during the experiment evidenced an input flux of Mg and Ca originating from a pool other than the labile pool. While the Mg input flux originated primarily from the weathering of primary minerals and secondarily from the non-crystalline phases, the Ca input flux originated primarily from the non-crystalline phases. Our results also show that the net calcium release flux from these phases may represent a significant source of calcium in forest ecosystems and actively contribute to compensating the depletion of Ca exchangeable pools in the soil. Non-crystalline phases therefore should be taken into account when computing input-output nutrient budgets and soil acid neutralizing capacity.
High-dose HOOK effect in urinary DcR2 assay in patients with chronic kidney disease.
Chen, Jia; Chen, Ke-Hong; Wang, Li-Ming; Zhang, Wei-Wei; Feng, Lei; Dai, Huan-Zi; He, Ya-Ni
2018-06-05
Urinary DcR2 (uDcR2) is a biomarker for the early detection the tubulointerstitial injury (TII) in patients with chronic kidney disease (CKD), but the high-dose hook effect may lead to falsely low or even negative results when using an enzyme-linked immunosorbent assay (ELISA). This study aimed to investigate if the high-dose hook effect exists with ELISA testing, and to uncover a potential approach for reducing this effect. 72 CKD patients were recruited and categorized into four groups based on TII scores. uDcR2 was measured in undiluted and serially diluted (two-, four-, eight- and 16-fold dilutions) urine using an ELISA kit. The results from the assay were normalized to urinary creatinine. We evaluated the correlation between uDcR2/cre levels at different dilutions and renal histological parameters. Receiver operating characteristic (ROC) curves were generated to examine the value of uDcR2/cre for predicting TII. uDcR2/cre levels in the undiluted urine were significantly higher in patients with CKD than those in the control. However, higher TII scores did not yield higher levels of uDcR2/cre in the undiluted urine. After serial dilution, uDcR2/cre levels were highest with the four-fold dilution. A positive correlation was found between uDcR2/cre levels at different dilutions and TII scores, with the highest correlation coefficient and the largest AUC being observed at the four-fold dilution. The high-dose hook effect was apparent during ELISA testing of uDcR2 in CKD patients, yet dilution of the urine samples neutralized this effect. However, the use of a four-fold dilution of urine for uDcR2/cre testing may eliminate the high-dose hook effect and make it possible to effectively monitor the severity of TII in CKD patients. Copyright © 2018. Published by Elsevier Inc.
Hanke, Alexander A; Maschler, Stephanie; Schöchl, Herbert; Flöricke, Felix; Görlinger, Klaus; Zanger, Klaus; Kienbaum, Peter
2011-02-10
Hypertonic saline hydroxyethyl starch (HH) has been recommended for first line treatment of hemorrhagic shock. Its effects on coagulation are unclear. We studied in vitro effects of HH dilution on whole blood coagulation and platelet function. Furthermore 7.2% hypertonic saline, 6% hydroxyethylstarch (as ingredients of HH), and 0.9% saline solution (as control) were tested in comparable dilutions to estimate specific component effects of HH on coagulation. The study was designed as experimental non-randomized comparative in vitro study. Following institutional review board approval and informed consent blood samples were taken from 10 healthy volunteers and diluted in vitro with either HH (HyperHaes, Fresenius Kabi, Germany), hypertonic saline (HT, 7.2% NaCl), hydroxyethylstarch (HS, HAES6%, Fresenius Kabi, Germany) or NaCl 0.9% (ISO) in a proportion of 5%, 10%, 20% and 40%. Coagulation was studied in whole blood by rotation thrombelastometry (ROTEM) after thromboplastin activation without (ExTEM) and with inhibition of thrombocyte function by cytochalasin D (FibTEM), the latter was performed to determine fibrin polymerisation alone. Values are expressed as maximal clot firmness (MCF, [mm]) and clotting time (CT, [s]). Platelet aggregation was determined by impedance aggregrometry (Multiplate) after activation with thrombin receptor-activating peptide 6 (TRAP) and quantified by the area under the aggregation curve (AUC [aggregation units (AU)/min]). Scanning electron microscopy was performed to evaluate HyperHaes induced cell shape changes of thrombocytes. 2-way ANOVA for repeated measurements, Bonferroni post hoc test, p < 0.01. Dilution impaired whole blood coagulation and thrombocyte aggregation in all dilutions in a dose dependent fashion. In contrast to dilution with ISO and HS, respectively, dilution with HH as well as HT almost abolished coagulation (MCFExTEM from 57.3 ± 4.9 mm (native) to 1.7 ± 2.2 mm (HH 40% dilution; p < 0.0001) and to 6.6 ± 3.4 mm (HT 40% dilution; p < 0.0001) and thrombocyte aggregation (AUC from 1067 ± 234 AU/mm (native) to 14.5 ± 12.5 AU/mm (HH 40% dilution; p < 0.0001) and to 20.4 ± 10.4 AU/min (HT 40% dilution; p < 0.0001) without differences between HH and HT (MCF: p = 0.452; AUC: p = 0.449). HH impairs platelet function during in vitro dilution already at 5% dilution. Impairment of whole blood coagulation is significant after 10% dilution or more. This effect can be pinpointed to the platelet function impairing hypertonic saline component and to a lesser extend to fibrin polymerization inhibition by the colloid component or dilution effects.Accordingly, repeated administration and overdosage should be avoided.
2011-01-01
Background Hypertonic saline hydroxyethyl starch (HH) has been recommended for first line treatment of hemorrhagic shock. Its effects on coagulation are unclear. We studied in vitro effects of HH dilution on whole blood coagulation and platelet function. Furthermore 7.2% hypertonic saline, 6% hydroxyethylstarch (as ingredients of HH), and 0.9% saline solution (as control) were tested in comparable dilutions to estimate specific component effects of HH on coagulation. Methods The study was designed as experimental non-randomized comparative in vitro study. Following institutional review board approval and informed consent blood samples were taken from 10 healthy volunteers and diluted in vitro with either HH (HyperHaes®, Fresenius Kabi, Germany), hypertonic saline (HT, 7.2% NaCl), hydroxyethylstarch (HS, HAES6%, Fresenius Kabi, Germany) or NaCl 0.9% (ISO) in a proportion of 5%, 10%, 20% and 40%. Coagulation was studied in whole blood by rotation thrombelastometry (ROTEM) after thromboplastin activation without (ExTEM) and with inhibition of thrombocyte function by cytochalasin D (FibTEM), the latter was performed to determine fibrin polymerisation alone. Values are expressed as maximal clot firmness (MCF, [mm]) and clotting time (CT, [s]). Platelet aggregation was determined by impedance aggregrometry (Multiplate) after activation with thrombin receptor-activating peptide 6 (TRAP) and quantified by the area under the aggregation curve (AUC [aggregation units (AU)/min]). Scanning electron microscopy was performed to evaluate HyperHaes induced cell shape changes of thrombocytes. Statistics: 2-way ANOVA for repeated measurements, Bonferroni post hoc test, p < 0.01. Results Dilution impaired whole blood coagulation and thrombocyte aggregation in all dilutions in a dose dependent fashion. In contrast to dilution with ISO and HS, respectively, dilution with HH as well as HT almost abolished coagulation (MCFExTEM from 57.3 ± 4.9 mm (native) to 1.7 ± 2.2 mm (HH 40% dilution; p < 0.0001) and to 6.6 ± 3.4 mm (HT 40% dilution; p < 0.0001) and thrombocyte aggregation (AUC from 1067 ± 234 AU/mm (native) to 14.5 ± 12.5 AU/mm (HH 40% dilution; p < 0.0001) and to 20.4 ± 10.4 AU/min (HT 40% dilution; p < 0.0001) without differences between HH and HT (MCF: p = 0.452; AUC: p = 0.449). Conclusions HH impairs platelet function during in vitro dilution already at 5% dilution. Impairment of whole blood coagulation is significant after 10% dilution or more. This effect can be pinpointed to the platelet function impairing hypertonic saline component and to a lesser extend to fibrin polymerization inhibition by the colloid component or dilution effects. Accordingly, repeated administration and overdosage should be avoided. PMID:21310047
Huillet, Céline; Adrait, Annie; Lebert, Dorothée; Picard, Guillaume; Trauchessec, Mathieu; Louwagie, Mathilde; Dupuis, Alain; Hittinger, Luc; Ghaleh, Bijan; Le Corvoisier, Philippe; Jaquinod, Michel; Garin, Jérôme; Bruley, Christophe; Brun, Virginie
2012-01-01
Development of new biomarkers needs to be significantly accelerated to improve diagnostic, prognostic, and toxicity monitoring as well as therapeutic follow-up. Biomarker evaluation is the main bottleneck in this development process. Selected Reaction Monitoring (SRM) combined with stable isotope dilution has emerged as a promising option to speed this step, particularly because of its multiplexing capacities. However, analytical variabilities because of upstream sample handling or incomplete trypsin digestion still need to be resolved. In 2007, we developed the PSAQ™ method (Protein Standard Absolute Quantification), which uses full-length isotope-labeled protein standards to quantify target proteins. In the present study we used clinically validated cardiovascular biomarkers (LDH-B, CKMB, myoglobin, and troponin I) to demonstrate that the combination of PSAQ and SRM (PSAQ-SRM) allows highly accurate biomarker quantification in serum samples. A multiplex PSAQ-SRM assay was used to quantify these biomarkers in clinical samples from myocardial infarction patients. Good correlation between PSAQ-SRM and ELISA assay results was found and demonstrated the consistency between these analytical approaches. Thus, PSAQ-SRM has the capacity to improve both accuracy and reproducibility in protein analysis. This will be a major contribution to efficient biomarker development strategies. PMID:22080464
Z.J. Wang; J.Y. Zhu; Ronald S. Jr. Zalesny; K.F. Chen
2012-05-01
Dilute acid (DA) and Sulfite Pretreatment to Overcome Recalcitrance of Lignocelluloses (SPORL) pretreatments were directly applied to wood chips of four poplar wood samples of different genotypes (hereafter referred to as poplars; Populus tremuloides Michx. ânative aspen collectionâ; Populus deltoides Bartr. ex Marsh x Populus nigra L. âNE222â and âDN5â; P. nigra x...
Machine for Automatic Bacteriological Pour Plate Preparation
Sharpe, A. N.; Biggs, D. R.; Oliver, R. J.
1972-01-01
A fully automatic system for preparing poured plates for bacteriological analyses has been constructed and tested. The machine can make decimal dilutions of bacterial suspensions, dispense measured amounts into petri dishes, add molten agar, mix the dish contents, and label the dishes with sample and dilution numbers at the rate of 2,000 dishes per 8-hr day. In addition, the machine can be programmed to select different media so that plates for different types of bacteriological analysis may be made automatically from the same sample. The machine uses only the components of the media and sterile polystyrene petri dishes; requirements for all other materials, such as sterile pipettes and capped bottles of diluents and agar, are eliminated. Images PMID:4560475
Structure of the enzymatically synthesized fructan inulin.
Heyer, A G; Schroeer, B; Radosta, S; Wolff, D; Czapla, S; Springer, J
1998-12-15
Construction, purification and characterization of a fusion protein of maltose-binding protein of Escherichia coli and the fructosyltransferase of Streptococcus mutans is described. With the purified protein, in vitro synthesis of inulin was performed. The obtained polysaccharide was characterized by high-performance size-exclusion chromatography (HPSEC) and static light scattering (SLS) in dilute aqueous and dimethyl sulfoxide solution. For all samples very high molecular weights between 60 x 10(6) and 90 x 10(6) g/mol and a remarkable small polydispersity index of 1.1 have been determined. Small root-mean-square radii of gyration point to a compact conformation in dilute solution. No difference between native and enzymatically synthesized inulin was observed by X-ray powder diffraction and thermoanalysis of solid samples.
Differential auger spectrometry
Strongin, Myron; Varma, Matesh Narayan; Anne, Joshi
1976-06-22
Differential Auger spectroscopy method for increasing the sensitivity of micro-Auger spectroanalysis of the surfaces of dilute alloys, by alternately periodically switching an electron beam back and forth between an impurity free reference sample and a test sample containing a trace impurity. The Auger electrons from the samples produce representative Auger spectrum signals which cancel to produce an Auger test sample signal corresponding to the amount of the impurity in the test samples.
High-concentration zeta potential measurements using light-scattering techniques
Kaszuba, Michael; Corbett, Jason; Watson, Fraser Mcneil; Jones, Andrew
2010-01-01
Zeta potential is the key parameter that controls electrostatic interactions in particle dispersions. Laser Doppler electrophoresis is an accepted method for the measurement of particle electrophoretic mobility and hence zeta potential of dispersions of colloidal size materials. Traditionally, samples measured by this technique have to be optically transparent. Therefore, depending upon the size and optical properties of the particles, many samples will be too concentrated and will require dilution. The ability to measure samples at or close to their neat concentration would be desirable as it would minimize any changes in the zeta potential of the sample owing to dilution. However, the ability to measure turbid samples using light-scattering techniques presents a number of challenges. This paper discusses electrophoretic mobility measurements made on turbid samples at high concentration using a novel cell with reduced path length. Results are presented on two different sample types, titanium dioxide and a polyurethane dispersion, as a function of sample concentration. For both of the sample types studied, the electrophoretic mobility results show a gradual decrease as the sample concentration increases and the possible reasons for these observations are discussed. Further, a comparison of the data against theoretical models is presented and discussed. Conclusions and recommendations are made from the zeta potential values obtained at high concentrations. PMID:20732896
Gulliksen, Anja; Keegan, Helen; Martin, Cara; O'Leary, John; Solli, Lars A.; Falang, Inger Marie; Grønn, Petter; Karlgård, Aina; Mielnik, Michal M.; Johansen, Ib-Rune; Tofteberg, Terje R.; Baier, Tobias; Gransee, Rainer; Drese, Klaus; Hansen-Hagge, Thomas; Riegger, Lutz; Koltay, Peter; Zengerle, Roland; Karlsen, Frank; Ausen, Dag; Furuberg, Liv
2012-01-01
The paper presents the development of a “proof-of-principle” hands-free and self-contained diagnostic platform for detection of human papillomavirus (HPV) E6/E7 mRNA in clinical specimens. The automated platform performs chip-based sample preconcentration, nucleic acid extraction, amplification, and real-time fluorescent detection with minimal user interfacing. It consists of two modular prototypes, one for sample preparation and one for amplification and detection; however, a common interface is available to facilitate later integration into one single module. Nucleic acid extracts (n = 28) from cervical cytology specimens extracted on the sample preparation chip were tested using the PreTect HPV-Proofer and achieved an overall detection rate for HPV across all dilutions of 50%–85.7%. A subset of 6 clinical samples extracted on the sample preparation chip module was chosen for complete validation on the NASBA chip module. For 4 of the samples, a 100% amplification for HPV 16 or 33 was obtained at the 1 : 10 dilution for microfluidic channels that filled correctly. The modules of a “sample-in, answer-out” diagnostic platform have been demonstrated from clinical sample input through sample preparation, amplification and final detection. PMID:22235204
Hamonts, Kelly; Kuhn, Thomas; Vos, Johan; Maesen, Miranda; Kalka, Harald; Smidt, Hauke; Springael, Dirk; Meckenstock, Rainer U; Dejonghe, Winnie
2012-04-15
Chlorinated aliphatic hydrocarbons (CAHs) often discharge into rivers as contaminated groundwater baseflow. Biotransformation, sorption and dilution of CAHs in the impacted river sediments have been reported to reduce discharge, but the effect of temporal variations in environmental conditions on the occurrence and extent of those processes in river sediments is largely unknown. We monitored the reduction of CAH discharge into the Zenne River during a 21-month period. Despite a relatively stable influx of CAHs from the groundwater, the total reduction in CAH discharge from 120 to 20 cm depth in the river sediments, on average 74 ± 21%, showed moderate to large temporal variations, depending on the riverbed location. High organic carbon and anaerobic conditions in the river sediments allowed microbial reductive dechlorination of both chlorinated ethenes and chlorinated ethanes. δ(13)C values of the CAHs showed that this biotransformation was remarkably stable over time, despite fluctuating pore water temperatures. Daughter products of the CAHs, however, were not detected in stoichiometric amounts and suggested the co-occurrence of a physical process reducing the concentrations of CAHs in the riverbed. This process was the main process causing temporal variations in natural attenuation of the CAHs and was most likely dilution by surface water-mixing. However, higher spatial resolution monitoring of flow transients in the riverbed is required to prove dilution contributions due to dynamic surface water-groundwater flow exchanges. δ(13)C values and a site-specific isotope enrichment factor for reductive dechlorination of the main groundwater pollutant vinyl chloride (VC) allowed assessment of changes over time in the extent of both biotransformation and dilution of VC for different scenarios in which those processes either occurred consecutively or simultaneously between 120 and 20 cm depth in the riverbed. The extent of reductive dechlorination of VC ranged from 27 to 89% and differed spatially but was remarkably stable over time, whereas the extent of VC reduction by dilution ranged from 6 to 94%, showed large temporal variations, and was often the main process contributing to the reduction of VC discharge into the river. Copyright © 2012 Elsevier Ltd. All rights reserved.
Chelinho, Sónia; Lopes, Isabel; Natal-da-Luz, Tiago; Domene, Xaxier; Nunes, Maria Edna Tenorio; Espíndola, Evaldo L G; Ribeiro, Rui; Sousa, Jose P
2012-02-01
The aim of the present study is to contribute an ecologically relevant assessment of the ecotoxicological effects of pesticide applications in agricultural areas in the tropics, using an integrated approach with information gathered from soil and aquatic compartments. Carbofuran, an insecticide/nematicide used widely on sugarcane crops, was selected as a model substance. To evaluate the toxic effects of pesticide spraying for soil biota, as well as the potential indirect effects on aquatic biota resulting from surface runoff and/or leaching, field and laboratory (using a cost-effective simulator of pesticide applications) trials were performed. Standard ecotoxicological tests were performed with soil (Eisenia andrei, Folsomia candida, and Enchytraeus crypticus) and aquatic (Ceriodaphnia silvestrii) organisms, using serial dilutions of soil, eluate, leachate, and runoff samples. Among soil organisms, sensitivity was found to be E. crypticus < E. andrei < F. candida. Among the aqueous extracts, mortality of C. silvestrii was extreme in runoff samples, whereas eluates were by far the least toxic samples. A generally higher toxicity was found in the bioassays performed with samples from the field trial, indicating the need for improvements in the laboratory simulator. However, the tool developed proved to be valuable in evaluating the toxic effects of pesticide spraying in soils and the potential risks for aquatic compartments. Copyright © 2011 SETAC.
Effects of an Extreme Flood on Trace Elements in River Water-From Urban Stream to Major River Basin.
Barber, Larry B; Paschke, Suzanne S; Battaglin, William A; Douville, Chris; Fitzgerald, Kevin C; Keefe, Steffanie H; Roth, David A; Vajda, Alan M
2017-09-19
Major floods adversely affect water quality through surface runoff, groundwater discharge, and damage to municipal water infrastructure. Despite their importance, it can be difficult to assess the effects of floods on streamwater chemistry because of challenges collecting samples and the absence of baseline data. This study documents water quality during the September 2013 extreme flood in the South Platte River, Colorado, USA. Weekly time-series water samples were collected from 3 urban source waters (municipal tap water, streamwater, and wastewater treatment facility effluent) under normal-flow and flood conditions. In addition, water samples were collected during the flood at 5 locations along the South Platte River and from 7 tributaries along the Colorado Front Range. Samples were analyzed for 54 major and trace elements. Specific chemical tracers, representing different natural and anthropogenic sources and geochemical behaviors, were used to compare streamwater composition before and during the flood. The results differentiate hydrological processes that affected water quality: (1) in the upper watershed, runoff diluted most dissolved constituents, (2) in the urban corridor and lower watershed, runoff mobilized soluble constituents accumulated on the landscape and contributed to stream loading, and (3) flood-induced groundwater discharge mobilized soluble constituents stored in the vadose zone.
Effects of an extreme flood on trace elements in river water—From urban stream to major river basin
Barber, Larry B.; Paschke, Suzanne; Battaglin, William A.; Douville, Chris; Fitzgerald, Kevin C.; Keefe, Steffanie H.; Roth, David A.; Vajda, Alan M.
2017-01-01
Major floods adversely affect water quality through surface runoff, groundwater discharge, and damage to municipal water infrastructure. Despite their importance, it can be difficult to assess the effects of floods on streamwater chemistry because of challenges collecting samples and the absence of baseline data. This study documents water quality during the September 2013 extreme flood in the South Platte River, Colorado, USA. Weekly time-series water samples were collected from 3 urban source waters (municipal tap water, streamwater, and wastewater treatment facility effluent) under normal-flow and flood conditions. In addition, water samples were collected during the flood at 5 locations along the South Platte River and from 7 tributaries along the Colorado Front Range. Samples were analyzed for 54 major and trace elements. Specific chemical tracers, representing different natural and anthropogenic sources and geochemical behaviors, were used to compare streamwater composition before and during the flood. The results differentiate hydrological processes that affected water quality: (1) in the upper watershed, runoff diluted most dissolved constituents, (2) in the urban corridor and lower watershed, runoff mobilized soluble constituents accumulated on the landscape and contributed to stream loading, and (3) flood-induced groundwater discharge mobilized soluble constituents stored in the vadose zone.
Wang, Hongxin; Friedrich, Stephan; Li, Lei; ...
2018-02-13
According to L-edge sum rules, the number of 3d vacancies at a transition metal site is directly proportional to the integrated intensity of the L-edge X-ray absorption spectrum (XAS) for the corresponding metal complex. In this study, the numbers of 3d holes are characterized quantitatively or semi-quantitatively for a series of manganese (Mn) and nickel (Ni) complexes, including the electron configurations 3d 10 → 3d 0. In addition, extremely dilute (<0.1% wt/wt) Ni enzymes were examined by two different approaches: (1) by using a high resolution superconducting tunnel junction X-ray detector to obtain XAS spectra with a very high signal-to-noisemore » ratio, especially in the non-variant edge jump region; and (2) by adding an inert tracer to the sample that provides a prominent spectral feature to replace the weak edge jump for intensity normalization. In this publication, we present for the first time: (1) L-edge sum rule analysis for a series of Mn and Ni complexes that include electron configurations from an open shell 3d0 to a closed shell 3d 10; (2) a systematic analysis on the uncertainties, especially on that from the edge jump, which was missing in all previous reports; (3) a clearly-resolved edge jump between pre-L 3 and post-L 2 regions from an extremely dilute sample; (4) an evaluation of an alternative normalization standard for L-edge sum rule analysis. XAS from two copper (Cu) proteins measured using a conventional semiconductor X-ray detector are also repeated as bridges between Ni complexes and dilute Ni enzymes. The differences between measuring 1% Cu enzymes and measuring <0.1% Ni enzymes are compared and discussed. As a result, this study extends L-edge sum rule analysis to virtually any 3d metal complex and any dilute biological samples that contain 3d metals.« less
Godin, Bruno; Nagle, Nick; Sattler, Scott; Agneessens, Richard; Delcarte, Jérôme; Wolfrum, Edward
2016-01-01
For biofuel production processes to be economically efficient, it is essential to maximize the production of monomeric carbohydrates from the structural carbohydrates of feedstocks. One strategy for maximizing carbohydrate production is to identify less recalcitrant feedstock cultivars by performing some type of experimental screening on a large and diverse set of candidate materials, or by identifying genetic modifications (random or directed mutations or transgenic plants) that provide decreased recalcitrance. Economic efficiency can also be increased using additional pretreatment processes such as deacetylation, which uses dilute NaOH to remove the acetyl groups of hemicellulose prior to dilute acid pretreatment. In this work, we used a laboratory-scale screening tool that mimics relevant thermochemical pretreatment conditions to compare the total sugar yield of three near-isogenic brown midrib ( bmr ) mutant lines and the wild-type (WT) sorghum cultivar. We then compared results obtained from the laboratory-scale screening pretreatment assay to a large-scale pretreatment system. After pretreatment and enzymatic hydrolysis, the bmr mutants had higher total sugar yields than the WT sorghum cultivar. Increased pretreatment temperatures increased reactivity for all sorghum samples reducing the differences observed at lower reaction temperatures. Deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples, and reduced the differences in total sugar yields among them, but solubilized a sizable fraction of the non-structural carbohydrates. The general trends of increased total sugar yield in the bmr mutant compared to the WT seen at the laboratory scale were observed at the large-scale system. However, in the larger reactor system, the measured total sugar yields were lower and the difference in total sugar yield between the WT and bmr sorghum was larger. Sorghum bmr mutants, which have a reduced lignin content showed higher total sugar yields than the WT cultivar after dilute acid pretreatment and enzymatic hydrolysis. Deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples. However, since deacetylation also solubilizes a large fraction of the non-structural carbohydrates, the ability to derive value from these solubilized sugars will depend greatly on the proposed conversion process.
Godin, Bruno; Nagle, Nick; Sattler, Scott; ...
2016-11-21
For biofuel production processes to be economically efficient, it is essential to maximize the production of monomeric carbohydrates from the structural carbohydrates of feedstocks. One strategy for maximizing carbohydrate production is to identify less recalcitrant feedstock cultivars by performing some type of experimental screening on a large and diverse set of candidate materials, or by identifying genetic modifications (random or directed mutations or transgenic plants) that provide decreased recalcitrance. Economic efficiency can also be increased using additional pretreatment processes such as deacetylation, which uses dilute NaOH to remove the acetyl groups of hemicellulose prior to dilute acid pretreatment. In thismore » work, we used a laboratory-scale screening tool that mimics relevant thermochemical pretreatment conditions to compare the total sugar yield of three near-isogenic brown midrib (bmr) mutant lines and the wild-type (WT) sorghum cultivar. We then compared results obtained from the laboratory-scale screening pretreatment assay to a large-scale pretreatment system. After pretreatment and enzymatic hydrolysis, the bmr mutants had higher total sugar yields than the WT sorghum cultivar. Increased pretreatment temperatures increased reactivity for all sorghum samples reducing the differences observed at lower reaction temperatures. Deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples, and reduced the differences in total sugar yields among them, but solubilized a sizable fraction of the non-structural carbohydrates. The general trends of increased total sugar yield in the bmr mutant compared to the WT seen at the laboratory scale were observed at the large-scale system. However, in the larger reactor system, the measured total sugar yields were lower and the difference in total sugar yield between the WT and bmr sorghum was larger. Sorghum bmr mutants, which have a reduced lignin content showed higher total sugar yields than the WT cultivar after dilute acid pretreatment and enzymatic hydrolysis. In conclusion, deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples. However, since deacetylation also solubilizes a large fraction of the non-structural carbohydrates, the ability to derive value from these solubilized sugars will depend greatly on the proposed conversion process.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Hongxin; Friedrich, Stephan; Li, Lei
According to L-edge sum rules, the number of 3d vacancies at a transition metal site is directly proportional to the integrated intensity of the L-edge X-ray absorption spectrum (XAS) for the corresponding metal complex. In this study, the numbers of 3d holes are characterized quantitatively or semi-quantitatively for a series of manganese (Mn) and nickel (Ni) complexes, including the electron configurations 3d 10 → 3d 0. In addition, extremely dilute (<0.1% wt/wt) Ni enzymes were examined by two different approaches: (1) by using a high resolution superconducting tunnel junction X-ray detector to obtain XAS spectra with a very high signal-to-noisemore » ratio, especially in the non-variant edge jump region; and (2) by adding an inert tracer to the sample that provides a prominent spectral feature to replace the weak edge jump for intensity normalization. In this publication, we present for the first time: (1) L-edge sum rule analysis for a series of Mn and Ni complexes that include electron configurations from an open shell 3d0 to a closed shell 3d 10; (2) a systematic analysis on the uncertainties, especially on that from the edge jump, which was missing in all previous reports; (3) a clearly-resolved edge jump between pre-L 3 and post-L 2 regions from an extremely dilute sample; (4) an evaluation of an alternative normalization standard for L-edge sum rule analysis. XAS from two copper (Cu) proteins measured using a conventional semiconductor X-ray detector are also repeated as bridges between Ni complexes and dilute Ni enzymes. The differences between measuring 1% Cu enzymes and measuring <0.1% Ni enzymes are compared and discussed. As a result, this study extends L-edge sum rule analysis to virtually any 3d metal complex and any dilute biological samples that contain 3d metals.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Godin, Bruno; Nagle, Nick; Sattler, Scott
For biofuel production processes to be economically efficient, it is essential to maximize the production of monomeric carbohydrates from the structural carbohydrates of feedstocks. One strategy for maximizing carbohydrate production is to identify less recalcitrant feedstock cultivars by performing some type of experimental screening on a large and diverse set of candidate materials, or by identifying genetic modifications (random or directed mutations or transgenic plants) that provide decreased recalcitrance. Economic efficiency can also be increased using additional pretreatment processes such as deacetylation, which uses dilute NaOH to remove the acetyl groups of hemicellulose prior to dilute acid pretreatment. In thismore » work, we used a laboratory-scale screening tool that mimics relevant thermochemical pretreatment conditions to compare the total sugar yield of three near-isogenic brown midrib (bmr) mutant lines and the wild-type (WT) sorghum cultivar. We then compared results obtained from the laboratory-scale screening pretreatment assay to a large-scale pretreatment system. After pretreatment and enzymatic hydrolysis, the bmr mutants had higher total sugar yields than the WT sorghum cultivar. Increased pretreatment temperatures increased reactivity for all sorghum samples reducing the differences observed at lower reaction temperatures. Deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples, and reduced the differences in total sugar yields among them, but solubilized a sizable fraction of the non-structural carbohydrates. The general trends of increased total sugar yield in the bmr mutant compared to the WT seen at the laboratory scale were observed at the large-scale system. However, in the larger reactor system, the measured total sugar yields were lower and the difference in total sugar yield between the WT and bmr sorghum was larger. Sorghum bmr mutants, which have a reduced lignin content showed higher total sugar yields than the WT cultivar after dilute acid pretreatment and enzymatic hydrolysis. In conclusion, deacetylation prior to dilute acid pretreatment increased the total sugar yield for all four sorghum samples. However, since deacetylation also solubilizes a large fraction of the non-structural carbohydrates, the ability to derive value from these solubilized sugars will depend greatly on the proposed conversion process.« less
Elilarassi, R; Chandrasekaran, G
2017-11-05
In the present investigation, diluted magnetic semiconductor (Zn 1-x Fe x O) nanoparticles with different doping concentrations (x=0, 0.02, 0.04, 0.06, and 0.08) were successfully synthesized by sol-gel auto-combustion method. The crystal structure, morphology, optical, electrical and magnetic properties of the prepared samples were characterized by X-ray diffraction (XRD), scanning electron microscope (SEM), energy dispersive analysis using x-rays (EDAX), ultraviolet-visible spectrophotometer, fluorescence spectroscope (FS), vibrating sample magnetometer (VSM) and broad band dielectric spectrometer (BDS). XRD results reveal that all the samples possess hexagonal wurtzite crystal structure with good crystalline quality. The absence of impurity phases divulge that Fe ions are well incorporated into the ZnO crystal lattice. The substitutional incorporation of Fe 3+ at Zn sites is reflected in optical absorption spectra of the samples. Flouorescence spectra of the samples show a strong near-band edge related UV emission as well as defect related visible emissions. The semiconducting behavior of the samples has been confirmed through electrical conductivity measurements. Magnetic measurements indicated that all the samples possess ferromagnetism at room temperature. Copyright © 2017 Elsevier B.V. All rights reserved.
Clinch River - Environmental Restoration Program (CR-ERP) study, ambient water toxicity
DOE Office of Scientific and Technical Information (OSTI.GOV)
Simbeck, D.J.
1997-06-01
Clinch River - Environmental Restoration Program (CR-ERP) personnel and Tennessee Valley Authority (TVA) personnel conducted a study during the week of April 14-21, 1994, as described in the Statement of Work (SOW) document. The organisms specified for testing were larval fathead minnows, Pimephales promelas, and the daphnid, Ceriodaphnia dubia. Surface water samples were collected by TVA Field Engineering personnel from Poplar Creek Mile 4.3, Poplar Creek Mile 5.1, and Poplar Creek Mile 6.0 on April 13, 15, and 18. Samples were partitioned (split) and provided to the CR-ERP and TVA toxicology laboratories for testing. Exposure of test organisms to thesemore » samples resulted in no toxicity (survival or growth) to daphnids in undiluted samples; however, toxicity to fathead minnows (significantly reduced survival) was demonstrated in undiluted samples from Poplar Creek Miles 4.3 and 6.0 in testing conducted by TVA based on hypothesis testing of data. Daphnid reproduction was significantly less than controls in 50 percent dilutions of samples from Poplar Creek Miles 4.3 and 6.0, while no toxicity to fathead minnows was shown in diluted (50 percent) samples.« less
Arul, Pitchaikaran; Pushparaj, Magesh; Pandian, Kanmani; Chennimalai, Lingasamy; Rajendran, Karthika; Selvaraj, Eniya; Masilamani, Suresh
2018-01-01
An important component of laboratory medicine is preanalytical phase. Since laboratory report plays a major role in patient management, more importance should be given to the quality of laboratory tests. The present study was undertaken to find the prevalence and types of preanalytical errors at a tertiary care hospital in South India. In this cross-sectional study, a total of 118,732 samples ([62,474 outpatient department [OPD] and 56,258 inpatient department [IPD]) were received in hematology laboratory. These samples were analyzed for preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples. The overall prevalence of preanalytical errors found was 513 samples, which is 0.43% of the total number of samples received. The most common preanalytical error observed was inadequate samples followed by clotted samples. Overall frequencies (both OPD and IPD) of preanalytical errors such as misidentification, incorrect vials, inadequate samples, clotted samples, diluted samples, and hemolyzed samples were 0.02%, 0.05%, 0.2%, 0.12%, 0.02%, and 0.03%, respectively. The present study concluded that incorrect phlebotomy techniques due to lack of awareness is the main reason for preanalytical errors. This can be avoided by proper communication and coordination between laboratory and wards, proper training and continuing medical education programs for laboratory and paramedical staffs, and knowledge of the intervening factors that can influence laboratory results.
The use of animal models in homeopathic research--a review of 2010-2014 PubMed indexed papers.
Bonamin, Leoni Villano; Cardoso, Thayná Neves; de Carvalho, Aloísio Cunha; Amaral, Juliana Gimenez
2015-10-01
In the 1990s, a study was performed on the effects of highly diluted thyroxine on frog metamorphosis. This model represented one of the most discussed examples of the biological effects of high dilutions over the next two decades. In 2010, another critical conceptual review of the use of animal models in homeopathy and high-dilution research was published. The main contribution of these studies was the elucidation of the biological features and phenomenology of the effects of high dilutions on living systems, representing an important step forward in our understanding of the mechanisms of action of homeopathic medicines. We performed a further review of this line of investigation using the same methods. Fifty-three articles that were indexed in the PubMed database and used 12 different animal species were systematically evaluated. Only a fraction of the studies (29/53) reported herein were performed with "ultra high" dilutions. The other studies were performed with dilutions in ranges below 10(-23) (14/53 articles) or commercial complexes (10/53 articles). Only two articles reported negative results; both used in vivo protocols to test commercial complexes, one in fish and one in bees. The quality of the employed techniques improved in 2010-2014 compared with the studies that were reviewed previously in 2010, with the inclusion of more ethically refined protocols, including in vitro primary cell cultures and ex vivo studies (10/53 articles), often with three or more replicates and analyses of epigenetic mechanisms that were previously unknown in 2010. In our updated review of the past 5 years, we found further demonstrations of the biological effects of homeopathy using more refined animal models and in vitro techniques. Copyright © 2015 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.
Li, Wei; Duan, Jinming; Niu, Chaoying; Qiang, Naichen; Mulcahy, Dennis
2011-10-01
A simple detection method using ultra-performance liquid chromatography electrospray ionisation tandem mass spectrometry (UPLC-ESI-MS-MS) coupled with the sample dilution method for determining trace microcystin-LR (MC-LR) in drinking water is presented. The limit of detection (LOD) was 0.04 µg/L and the limit of quantitation (LOQ) was 0.1 µg/L. Water matrix effects of ionic strength, dissolved organic carbon (DOC) and pH were examined. The results indicate that signal detection intensity for MC-LR was significantly suppressed as the ionic strength increased from ultrapure water condition, whereas it increased slightly with solution pH and DOC at low concentrations. However, addition of methanol (MeOH) into the sample was able to counter the signal suppression effects. In this study, dilution of the tap water sample by adding 4% MeOH (v/v) was observed to be adequate to compensate for the signal suppression. The recoveries of the samples fortified with MC-LR (0.2, 1, and 10 µg/L) for three different tap water samples ranged from 84.4% to 112.9%.
Transport properties of dilute α -Fe (X ) solid solutions (X = C, N, O)
NASA Astrophysics Data System (ADS)
Schuler, Thomas; Nastar, Maylise
2016-06-01
We extend the self-consistent mean field (SCMF) method to the calculation of the Onsager matrix of Fe-based interstitial solid solutions. Both interstitial jumps and substitutional atom-vacancy exchanges are accounted for. A general procedure is introduced to split the Onsager matrix of a dilute solid solution into intrinsic cluster Onsager matrices, and extract from them flux-coupling ratios, mobilities, and association-dissociation rates for each cluster. The formalism is applied to vacancy-interstitial solute pairs in α -Fe (V X pairs, X = C, N, O), with ab initio based thermodynamic and kinetic parameters. Convergence of the cluster mobility contribution gives a controlled estimation of the cluster definition distance, taking into account both its thermodynamic and kinetic properties. Then, the flux-coupling behavior of each V X pair is discussed, and qualitative understanding is achieved from the comparison between various contributions to the Onsager matrix. Also, the effect of low-activation energy second-nearest-neighbor interstitial solute jumps around a vacancy on these results is addressed.
Ceçen, F; Yangin, C
2000-12-01
This study examined the determination of BOD in landfill leachates by dilution (D-method) and manometric methods (M-method). The differences in results were discussed based on statistical tests. The effects of sample dilution, seeding, chloride and total Kjeldahl nitrogen (TKN) level were examined. The M-method was found to be more sensitive to increases in chloride and TKN concentrations. However, in the M-method the positive interference of nitrogenous BOD (NBOD) to carbonaceous BOD (CBOD) was more successfully prevented. The BOD rate constant k and the ultimate BOD (BODu) were estimated by non-linear regression. With the M-method these parameters could be more reliably estimated than the D-method. Suggestions were made for BOD analyses in landfill leachates in future studies.
Fagyas, Miklós; Úri, Katalin; Siket, Ivetta M.; Daragó, Andrea; Boczán, Judit; Bányai, Emese; Édes, István; Papp, Zoltán; Tóth, Attila
2014-01-01
Angiotensin-converting enzyme (ACE) inhibitors represent the fifth most often prescribed drugs. ACE inhibitors decrease 5-year mortality by approximately one-fifth in cardiovascular patients. Surprisingly, there are reports dating back to 1979 suggesting the existence of endogenous ACE inhibitors, which endogenous inhibitory effects are much less characterized than that for the clinically administered ACE inhibitors. Here we aimed to investigate this endogenous ACE inhibition in human sera. It was hypothesized that ACE activity is masked by an endogenous inhibitor, which dissociates from the ACE when its concentration decreases upon dilution. ACE activity was measured by FAPGG hydrolysis first. The specific (dilution corrected) enzyme activities significantly increased by dilution of human serum samples (23.2±0.7 U/L at 4-fold dilution, 51.4±0.3 U/L at 32-fold dilution, n = 3, p = 0.001), suggesting the presence of an endogenous inhibitor. In accordance, specific enzyme activities did not changed by dilution when purified renal ACE was used, where no endogenous inhibitor was present (655±145 U/L, 605±42 U/L, n = 3, p = 0.715, respectively). FAPGG conversion strongly correlated with angiotensin I conversion suggesting that this feature is not related to the artificial substrate. Serum samples were ultra-filtered to separate ACE (MW: 180 kDa) and the hypothesized inhibitor. Filtering through 50 kDa filters was without effect, while filtering through 100 kDa filters eliminated the inhibiting factor (ACE activity after <100 kDa filtering: 56.4±2.4 U/L, n = 4, control: 26.4±0.7 U/L, n = 4, p<0.001). Lineweaver-Burk plot indicated non-competitive inhibition of ACE by this endogenous factor. The endogenous inhibitor had higher potency on the C-terminal active site than N-terminal active site of ACE. Finally, this endogenous ACE inhibition was also present in mouse, donkey, goat, bovine sera besides men (increasing of specific ACE activity from 4-fold to 32-fold dilution: 2.8-fold, 1.7-fold, 1.5-fold, 1.8-fold, 2.6-fold, respectively). We report here the existence of an evolutionary conserved mechanism suppressing circulating ACE activity, in vivo, similarly to ACE inhibitory drugs. PMID:24691160
Bottomley, Peter J.; Dughri, Muktar H.
1989-01-01
Bacterial cells small enough to pass through 0.4-μm-pore-size filters made up 5 to 9% of the indigenous bacterial population in 0- to 20-cm-depth samples of Abiqua silty clay loam. Within the same soil samples, cells of a similar dimension were stained with fluorescent antibodies specific to each of four antigenically distinct indigenous serogroups of Rhizobium leguminosarum bv. trifolii and made up 22 to 34% of the soil population of the four serogroups. Despite the extensive contribution of small cells to these soil populations, no evidence of their being capable of either growth or nodulation was obtained. The density of soil bacteria which could be cultured ranged between 0.5 and 8.5% of the >0.4-μm direct count regardless of media, season of sampling, or soil depth. In the same soil samples, the viable nodulating populations of biovar trifolii determined by the plant infection soil dilution technique ranged between 1 and 10% of the >0.4-μm direct-immunofluorescence count of biovar trifolii. The <0.4-μm cell populations of both total soil bacteria and biovar trifolii changed abruptly between the 10- to 15-cm and 15- to 20-cm soil depth increments, increasing from 5 to 20% and from 20 to 50%, respectively, of their direct-count totals. The increase in density of the small-cell population corresponded to a significant increase in soil bulk density (1.07 to 1.21 g cm−3). The percent contribution of the <0.4-μm direct count to individual serogroup totals increased with soil depth by approximately 2-fold (39 to 87%) for serogroups 17 and 21 and by 12-fold (6 to 75%) for serogroups 6 and 36. PMID:16347896
Capesius, Joseph P.; Sullivan, Joseph R.; O'Neill, Gregory B.; Williams, Cory A.
2005-01-01
Accurate ice-affected streamflow records are difficult to obtain for several reasons, which makes the management of instream-flow water rights in the wintertime a challenging endeavor. This report documents a method to improve ice-affected streamflow records for two gaging stations in Colorado. In January and February 2002, the U.S. Geological Survey, in cooperation with the Colorado Water Conservation Board, conducted an experiment using a sodium chloride tracer to measure streamflow under ice cover by the tracer-dilution discharge method. The purpose of this study was to determine the feasibility of obtaining accurate ice-affected streamflow records by using a sodium chloride tracer that was injected into the stream. The tracer was injected at two gaging stations once per day for approximately 20 minutes for 25 days. Multiple-parameter water-quality sensors at the two gaging stations monitored background and peak chloride concentrations. These data were used to determine discharge at each site. A comparison of the current-meter streamflow record to the tracer-dilution streamflow record shows different levels of accuracy and precision of the tracer-dilution streamflow record at the two sites. At the lower elevation and warmer site, Brandon Ditch near Whitewater, the tracer-dilution method overestimated flow by an average of 14 percent, but this average is strongly biased by outliers. At the higher elevation and colder site, Keystone Gulch near Dillon, the tracer-dilution method experienced problems with the tracer solution partially freezing in the injection line. The partial freezing of the tracer contributed to the tracer-dilution method underestimating flow by 52 percent at Keystone Gulch. In addition, a tracer-pump-reliability test was conducted to test how accurately the tracer pumps can discharge the tracer solution in conditions similar to those used at the gaging stations. Although the pumps were reliable and consistent throughout the 25-day study period, the pumps underdischarged the tracer by 5.8-15.9 percent as compared to the initial pumping rate setting, which may explain some of the error in the tracer-dilution streamflow record as compared to current-meter streamflow record.
Detection of Gastrointestinal Pathogens from Stool Samples on Hemoccult Cards by Multiplex PCR
Schlenker, Nicklas; Bauer, Malkin; Helfrich, Kerstin; Mengele, Carolin; Löscher, Thomas; Nothdurft, Hans Dieter; Bretzel, Gisela; Beissner, Marcus
2017-01-01
Purpose. Up to 30% of international travelers are affected by travelers' diarrhea (TD). Reliable data on the etiology of TD is lacking. Sufficient laboratory capacity at travel destinations is often unavailable and transporting conventional stool samples to the home country is inconvenient. We evaluated the use of Hemoccult cards for stool sampling combined with a multiplex PCR for the detection of model viral, bacterial, and protozoal TD pathogens. Methods. Following the creation of serial dilutions for each model pathogen, last positive dilution steps (LPDs) and thereof calculated last positive sample concentrations (LPCs) were compared between conventional stool samples and card samples. Furthermore, card samples were tested after a prolonged time interval simulating storage during a travel duration of up to 6 weeks. Results. The LPDs/LPCs were comparable to testing of conventional stool samples. After storage on Hemoccult cards, the recovery rate was 97.6% for C. jejuni, 100% for E. histolytica, 97.6% for norovirus GI, and 100% for GII. Detection of expected pathogens was possible at weekly intervals up to 42 days. Conclusion. Stool samples on Hemoccult cards stored at room temperature can be used in combination with a multiplex PCR as a reliable tool for testing of TD pathogens. PMID:28408937
Granato, Gregory E.; Smith, Kirk P.
1999-01-01
Discrete or composite samples of highway runoff may not adequately represent in-storm water-quality fluctuations because continuous records of water stage, specific conductance, pH, and temperature of the runoff indicate that these properties fluctuate substantially during a storm. Continuous records of water-quality properties can be used to maximize the information obtained about the stormwater runoff system being studied and can provide the context needed to interpret analyses of water samples. Concentrations of the road-salt constituents calcium, sodium, and chloride in highway runoff were estimated from theoretical and empirical relations between specific conductance and the concentrations of these ions. These relations were examined using the analysis of 233 highwayrunoff samples collected from August 1988 through March 1995 at four highway-drainage monitoring stations along State Route 25 in southeastern Massachusetts. Theoretically, the specific conductance of a water sample is the sum of the individual conductances attributed to each ionic species in solution-the product of the concentrations of each ion in milliequivalents per liter (meq/L) multiplied by the equivalent ionic conductance at infinite dilution-thereby establishing the principle of superposition. Superposition provides an estimate of actual specific conductance that is within measurement error throughout the conductance range of many natural waters, with errors of less than ?5 percent below 1,000 microsiemens per centimeter (?S/cm) and ?10 percent between 1,000 and 4,000 ?S/cm if all major ionic constituents are accounted for. A semi-empirical method (adjusted superposition) was used to adjust for concentration effects-superposition-method prediction errors at high and low concentrations-and to relate measured specific conductance to that calculated using superposition. The adjusted superposition method, which was developed to interpret the State Route 25 highway-runoff records, accounts for contributions of constituents other than calcium, sodium, and chloride in dilute waters. The adjusted superposition method also accounts for the attenuation of each constituent's contribution to conductance as ionic strength increases. Use of the adjusted superposition method generally reduced predictive error to within measurement error throughout the range of specific conductance (from 37 to 51,500 ?S/cm) in the highway runoff samples. The effects of pH, temperature, and organic constituents on the relation between concentrations of dissolved constituents and measured specific conductance were examined but these properties did not substantially affect interpretation of the Route 25 data set. Predictive abilities of the adjusted superposition method were similar to results obtained by standard regression techniques, but the adjusted superposition method has several advantages. Adjusted superposition can be applied using available published data about the constituents in precipitation, highway runoff, and the deicing chemicals applied to a highway. This semi-empirical method can be used as a predictive and diagnostic tool before a substantial number of samples are collected, but the power of the regression method is based upon a large number of water-quality analyses that may be affected by a bias in the data.
Purdy, P H; Tharp, N; Stewart, T; Spiller, S F; Blackburn, H D
2010-10-15
Boar semen is typically collected, diluted and cooled for AI use over numerous days, or frozen immediately after shipping to capable laboratories. The storage temperature and pH of the diluted, cooled boar semen could influence the fertility of boar sperm. Therefore, the purpose of this study was to determine the effects of pH and storage temperature on fresh and frozen-thawed boar sperm motility end points. Semen samples (n = 199) were collected, diluted, cooled and shipped overnight to the National Animal Germplasm Program laboratory for freezing and analysis from four boar stud facilities. The temperature, pH and motility characteristics, determined using computer automated semen analysis, were measured at arrival. Samples were then cryopreserved and post-thaw motility determined. The commercial stud was a significant source of variation for mean semen temperature and pH, as well as total and progressive motility, and numerous other sperm motility characteristics. Based on multiple regression analysis, pH was not a significant source of variation for fresh or frozen-thawed boar sperm motility end points. However, significant models were derived which demonstrated that storage temperature, boar, and the commercial stud influenced sperm motility end points and the potential success for surviving cryopreservation. We inferred that maintaining cooled boar semen at approximately 16 °C during storage will result in higher fresh and frozen-thawed boar sperm quality, which should result in greater fertility. Copyright © 2010 Elsevier Inc. All rights reserved.
Evaluation of the VERSANT HCV RNA 3.0 assay for quantification of hepatitis C virus RNA in serum.
Trimoulet, Pascale; Halfon, Philippe; Pohier, Eric; Khiri, Hacène; Chêne, Geneviève; Fleury, Hervé
2002-06-01
We assessed the performance of a new assay (VERSANT HCV RNA 3.0 [bDNA 3.0] assay [Bayer Diagnostics]) to quantitate HCV RNA levels and compared the results of the bDNA 3.0 assay to results of the Quantiplex HCV RNA 2.0 (bDNA 2.0) assay. Samples used in this study included 211 serum specimens from hepatitis C virus (HCV)-infected persons from two sites (Bordeaux and Marseille, France) with different genotypes; 383 serum specimens from HCV antibody-negative, HCV RNA-negative persons; and serial dilutions of World Health Organization (WHO) HCV RNA standard at a titer of 100,000 IU/ml. The specificity of the bDNA 3.0 assay was 98.2%. A high correlation was observed between expected and observed values in all dilutions of WHO standard (r = 0.9982), in serial dilutions of pooled samples (r = 0.9996), and in diluted sera from different HCV genotypes (r = 0.9930 to 0.9995). The standard deviations (SD) for the within-run and between-run reproducibility of the bDNA 3.0 assay were
Evaluation of the VERSANT HCV RNA 3.0 Assay for Quantification of Hepatitis C Virus RNA in Serum
Trimoulet, Pascale; Halfon, Philippe; Pohier, Eric; Khiri, Hacène; Chêne, Geneviève; Fleury, Hervé
2002-01-01
We assessed the performance of a new assay (VERSANT HCV RNA 3.0 [bDNA 3.0] assay [Bayer Diagnostics]) to quantitate HCV RNA levels and compared the results of the bDNA 3.0 assay to results of the Quantiplex HCV RNA 2.0 (bDNA 2.0) assay. Samples used in this study included 211 serum specimens from hepatitis C virus (HCV)-infected persons from two sites (Bordeaux and Marseille, France) with different genotypes; 383 serum specimens from HCV antibody-negative, HCV RNA-negative persons; and serial dilutions of World Health Organization (WHO) HCV RNA standard at a titer of 100,000 IU/ml. The specificity of the bDNA 3.0 assay was 98.2%. A high correlation was observed between expected and observed values in all dilutions of WHO standard (r = 0.9982), in serial dilutions of pooled samples (r = 0.9996), and in diluted sera from different HCV genotypes (r = 0.9930 to 0.9995). The standard deviations (SD) for the within-run and between-run reproducibility of the bDNA 3.0 assay were ≤0.2 and ≤0.14, respectively. The intersite SD ranged from 0.03 to 0.14. The bDNA 3.0 assay results were positively correlated with the bDNA 2.0 assay results (r = 0.9533). Taking in account the overall performance, this assay could be used as a routine tool for the HCV RNA quantification. PMID:12037059
Chełmońska, Bronisława; Łukaszewicz, Ewa; Kowalczyk, Artur; Jerysz, Anna
2006-01-20
The effect of different levels (2, 4 or 6%) of DMA (dimethylacetamide) on the morphology and fertilising ability of unfrozen quail spermatozoa was evaluated. Semen was collected from 72 males kept individually in cages and randomly divided into four groups: Group I--control -- fresh undiluted semen (12 males) and three experimental groups (20 males each) - semen diluted 1:1 with Lake's extender and supplemented with 2% (Group II), 4% (Group III) or 6% (Group IV) of DMA (final concentration). Sperm morphology was evaluated at each step of semen preparation, i.e. in fresh and diluted semen, semen supplemented with DMA and semen that remained after insemination. For fertility tests, 36 females were divided into four groups (nine females each). Females in the control group were inseminated with 10 microl of fresh semen, in the experimental groups with 40 microl of diluted semen. Each stage of quail semen treatment had a deleterious effect on sperm morphology. The highest percentage of morphologically normal cells in semen evaluated after insemination, was observed in samples with 2% DMA, and the lowest--in samples with 6% DMA. Semen dilution and DMA addition significantly affected the fertilising potency of spermatozoa. Fertility of eggs collected from the control group (71.5% on average) was significantly higher (P
Sonntag, Darrell B; Gao, H Oliver; Holmén, Britt A
2008-08-01
A linear mixed model was developed to quantify the variability of particle number emissions from transit buses tested in real-world driving conditions. Two conventional diesel buses and two hybrid diesel-electric buses were tested throughout 2004 under different aftertreatments, fuels, drivers, and bus routes. The mixed model controlled the confounding influence of factors inherent to on-board testing. Statistical tests showed that particle number emissions varied significantly according to the after treatment, bus route, driver, bus type, and daily temperature, with only minor variability attributable to differences between fuel types. The daily setup and operation of the sampling equipment (electrical low pressure impactor) and mini-dilution system contributed to 30-84% of the total random variability of particle measurements among tests with diesel oxidation catalysts. By controlling for the sampling day variability, the model better defined the differences in particle emissions among bus routes. In contrast, the low particle number emissions measured with diesel particle filters (decreased by over 99%) did not vary according to operating conditions or bus type but did vary substantially with ambient temperature.
21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.
Code of Federal Regulations, 2013 CFR
2013-04-01
... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...
21 CFR 177.1950 - Vinyl chloride-ethylene copolymers.
Code of Federal Regulations, 2012 CFR
2012-04-01
... deciliter per gram as determined by ASTM method D1243-79, “Standard Test Method for Dilute Solution... vinyl chloride-ethylene copol-ymer per 100 grams of sample tested as determined from the organic... using duplicate blanks. Approximately 400 grams of sample (accurately weighed) shall be placed in a 2...
This poster presentation will describe analytical chemistry methods for measuring thyroid hormones and related precursors and metabolites in very small tissue or plasma samples. These methods are amenable to measure thyroid hormones in amphibian tadpoles or small mammals used as ...
Measurement of fumonisins in corn with a fiber optic fluoroimmunosensor
NASA Astrophysics Data System (ADS)
Thompson, Vicki S.; Maragos, Chris M.
1997-05-01
A fiber-optic immunosensor was used to determine concentrations of the mycotoxin fumonisin B1(FB1) in both spiked and naturally contaminated corn samples. Samples were extracted with a mixture of methanol/water. Two methods were used to prepare the methanolic corn extracts before introduction to the immunosensor: (1) simple dilution of the methanolic corn extract; or (2) affinity column cleanup. The sensor displayed an IC50 of 70 ng FB1/mL when toxin was introduced in phosphate buffered saline. Simple dilution of methanolic corn extracts yielded an assay with an IC50 equivalent to 25 (mu) gFB1/g corn and a limit of detection of 3.2 (mu) g/g corn, while affinity cleanup of corn extracts yielded an assay with an IC50 of 5 (mu) gFB1/g corn and a limit of detection of 0.4 (mu) gFB1/g corn. The difference in sensitivity between the two cleanup techniques was due to concentration of fumonisins obtained from the affinity cleanup procedure. Naturally contaminated corn samples were also analyzed after either simple dilution or affinity column cleanup. For comparison the naturally contaminated corn samples were analyzed with an HPLC method after isolation of the fumonisins with strong anion exchange (SAX) solid phase extraction cartridges. The SAX/HPLC method and the immunosensor method agreed well except when large amounts of other fumonisins (i.e. fumonisin B2) were present. This was due in part to the cross-reactivity of the monoclonal antibody with other fumonisins. The immunosensor has the potential to screen individual corn samples for fumonisins within six minutes, and is among the fastest of the currently available FB1 detection methods.
Failure mode analysis in adrenal vein sampling: a single-center experience.
Trerotola, Scott O; Asmar, Melissa; Yan, Yan; Fraker, Douglas L; Cohen, Debbie L
2014-10-01
To analyze failure modes in a high-volume adrenal vein sampling (AVS) practice in an effort to identify preventable causes of nondiagnostic sampling. A retrospective database was constructed containing 343 AVS procedures performed over a 10-year period. Each nondiagnostic AVS procedure was reviewed for failure mode and correlated with results of any repeat AVS. Data collected included selectivity index, lateralization index, adrenalectomy outcomes if performed, and details of AVS procedure. All AVS procedures were performed after cosyntropin stimulation, using sequential technique. AVS was nondiagnostic in 12 of 343 (3.5%) primary procedures and 2 secondary procedures. Failure was right-sided in 8 (57%) procedures, left-sided in 4 (29%) procedures, bilateral in 1 procedure, and neither in 1 procedure (laboratory error). Failure modes included diluted sample from correctly identified vein (n = 7 [50%]; 3 right and 4 left), vessel misidentified as adrenal vein (n = 3 [21%]; all right), failure to locate an adrenal vein (n = 2 [14%]; both right), cosyntropin stimulation failure (n = 1 [7%]; diagnostic by nonstimulated criteria), and laboratory error (n = 1 [7%]; specimen loss). A second AVS procedure was diagnostic in three of five cases (60%), and a third AVS procedure was diagnostic in one of one case (100%). Among the eight patients in whom AVS ultimately was not diagnostic, four underwent adrenalectomy based on diluted AVS samples, and one underwent adrenalectomy based on imaging; all five experienced improvement in aldosteronism. A substantial percentage of AVS failures occur on the left, all related to dilution. Even when technically nondiagnostic per strict criteria, some "failed" AVS procedures may be sufficient to guide therapy. Repeat AVS has a good yield. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2013 CFR
2013-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2014 CFR
2014-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2011 CFR
2011-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2010 CFR
2010-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
40 CFR 86.159-08 - Exhaust emission test procedures for US06 emissions.
Code of Federal Regulations, 2012 CFR
2012-07-01
... gasoline-fueled Otto-cycle vehicles, the composite samples collected in bags are analyzed for THC, CO, CO2, CH4, and NOX. For petroleum-fueled diesel-cycle vehicles, THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel bag samples of dilution air are analyzed for THC, CO, CO2...
Pontoni, Ludovico; Panico, Antonio; Matanò, Alessia; van Hullebusch, Eric D; Fabbricino, Massimiliano; Esposito, Giovanni; Pirozzi, Francesco
2017-12-06
A novel modification of the sample preparation procedure for the Folin-Ciocalteu colorimetric assay for the determination of total phenolic compounds in natural solid and semisolid organic materials (e.g., foods, organic solid waste, soils, plant tissues, agricultural residues, manure) is proposed. In this method, the sample is prepared by adding sodium sulfate as a solid diluting agent before homogenization. The method allows for the determination of total phenols (TP) in samples with high solids contents, and it provides good accuracy and reproducibility. Additionally, this method permits analyses of significant amounts of sample, which reduces problems related to heterogeneity. We applied this method to phenols-rich lignocellulosic and humic-like solids and semisolid samples, including rice straw (RS), peat-rich soil (PS), and food waste (FW). The TP concentrations measured with the solid dilution (SD) preparation were substantially higher (increases of 41.4%, 15.5%, and 59.4% in RS, PS and FW, respectively) than those obtained with the traditional method (solids suspended in water). These results showed that the traditional method underestimates the phenolic contents in the studied solids.
Roberts, S M; Severin, G A; Lavach, J D
1986-06-01
Bacterial cultures of specimens from healthy canine eyelids and ocular surfaces were found to demonstrate bacterial growth in 69.7% (53/76) of the eyes sampled. Organisms most commonly isolated included: Staphylococcus aureus, alpha-hemolytic Streptococcus sp, S epidermidis, and Escherichia coli. Evaluation of dilute povidone-iodine solutions for effectiveness as ocular surface disinfectants was conducted. Bacterial growth initially detected in 32 of 46 eyes was not detected after disinfection with a 2-minute scrub and 2-minute soaking procedure, using 1:2, 1:10, or 1:50 dilutions of a povidone-iodine solution that contained 1% available iodine. The eyelid and ocular surfaces of 16 eyes were disinfected with 1:100 povidone-iodine solution. Bacterial growth initially present in 10 of 16 eyes was present in 1 eye after disinfection and consisted of a single colony of E coli. After eyes were disinfected with 1:10, 1:50, or 1:100 povidone-iodine solutions, there was no evidence of corneal epithelial edema or sloughing. In 15 eyes subjected to disinfection with the 1:2 dilution, one instance of epithelial corneal edema was noticed. A 1:50 dilution of povidone-iodine is recommended as an ocular surface disinfectant for use in presurgical situations.
Nucleation mode particles with a nonvolatile core in the exhaust of a heavy duty diesel vehicle.
Rönkkö, Topi; Virtanen, Annele; Kannosto, Jonna; Keskinen, Jorma; Lappi, Maija; Pirjola, Liisa
2007-09-15
The characteristics of the nucleation mode particles of a Euro IV heavy-duty diesel vehicle exhaust were studied. The NOx and PM emissions of the vehicle were controlled through the use of cooled EGR and high-pressure fuel injection techniques; no exhaust gas after-treatment was used. Particle measurements were performed in vehicle laboratory and on road. Nucleation mode dominated the particle number size distribution in all the tested driving conditions. According to the on-road measurements, the nucleation mode was already formed after 0.7 s residence time in the atmosphere and no significant changes were observed for longer residence times. The nucleation mode was insensitive to the fuel sulfur content, dilution air temperature, and relative humidity. An increase in the dilution ratio decreased the size of the nucleation mode particles. This behavior was observed to be linked to the total hydrocarbon concentration in the diluted sample. In volatility measurements, the nucleation mode particles were observed to have a nonvolatile core with volatile species condensed on it. The results indicate that the nucleation mode particles have a nonvolatile core formed before the dilution process. The core particles have grown because of the condensation of semivolatile material, mainly hydrocarbons, during the dilution.
2014-01-01
Background There is considerable interest in the conversion of lignocellulosic biomass to liquid fuels to provide substitutes for fossil fuels. Pretreatments, conducted to reduce biomass recalcitrance, usually remove at least some of the hemicellulose and/or lignin in cell walls. The hypothesis that led to this research was that reactor type could have a profound effect on the properties of pretreated materials and impact subsequent cellulose hydrolysis. Results Corn stover was dilute-acid pretreated using commercially relevant reactor types (ZipperClave® (ZC), Steam Gun (SG) and Horizontal Screw (HS)) under the same nominal conditions. Samples produced in the SG and HS achieved much higher cellulose digestibilities (88% and 95%, respectively), compared to the ZC sample (68%). Characterization, by chemical, physical, spectroscopic and electron microscopy methods, was used to gain an understanding of the effects causing the digestibility differences. Chemical differences were small; however, particle size differences appeared significant. Sum-frequency generation vibrational spectra indicated larger inter-fibrillar spacing or randomization of cellulose microfibrils in the HS sample. Simons’ staining indicated increased cellulose accessibility for the SG and HS samples. Electron microscopy showed that the SG and HS samples were more porous and fibrillated because of mechanical grinding and explosive depressurization occurring with these two reactors. These structural changes most likely permitted increased cellulose accessibility to enzymes, enhancing saccharification. Conclusions Dilute-acid pretreatment of corn stover using three different reactors under the same nominal conditions gave samples with very different digestibilities, although chemical differences in the pretreated substrates were small. The results of the physical and chemical analyses of the samples indicate that the explosive depressurization and mechanical grinding with these reactors increased enzyme accessibility. Pretreatment reactors using physical force to disrupt cell walls increase the effectiveness of the pretreatment process. PMID:24713111
Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C
2012-12-21
Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.
Roest, Kees; Altinbas, Mahmut; Paulo, Paula L; Heilig, H G H J; Akkermans, Antoon D L; Smidt, Hauke; de Vos, Willem M; Stams, Alfons J M
2005-10-01
To gain insight into the microorganisms involved in direct and indirect methane formation from methanol in a laboratory-scale thermophilic (55 degrees C) methanogenic bioreactor, reactor sludge was disrupted and serial dilutions were incubated in specific growth media containing methanol and possible intermediates of methanol degradation as substrates. With methanol, growth was observed up to a dilution of 10(8). However, when Methanothermobacter thermoautotrophicus strain Z245 was added for H2 removal, growth was observed up to a 10(10)-fold dilution. With H2/CO2 and acetate, growth was observed up to dilutions of 10(9) and 10(4), respectively. Dominant microorganisms in the different dilutions were identified by 16S rRNA-gene diversity and sequence analysis. Furthermore, dilution polymerase chain reaction (PCR) revealed a similar relative abundance of Archaea and Bacteria in all investigated samples, except in enrichment with acetate, which contained 100 times less archaeal DNA than bacterial DNA. The most abundant bacteria in the culture with methanol and strain Z245 were most closely related to Moorella glycerini. Thermodesulfovibrio relatives were found with high sequence similarity in the H2/CO2 enrichment, but also in the original laboratory-scale bioreactor sludge. Methanothermobacter thermoautotrophicus strains were the most abundant hydrogenotrophic archaea in the H2/CO2 enrichment. The dominant methanol-utilizing methanogen, which was present in the 10(8)-dilution, was most closely related to Methanomethylovorans hollandica. Compared to direct methanogenesis, results of this study indicate that syntrophic, interspecies hydrogen transfer-dependent methanol conversion is equally important in the thermophilic bioreactor, confirming previous findings with labeled substrates and specific inhibitors.
Zdolsek, J H; Bergek, C; Lindahl, T L; Hahn, R G
2015-11-01
During fluid infusion therapy, plasma proteins are diluted and leak from the intravascular space, which alters the colloid osmotic pressure (COP) and potentially affects coagulation. We hypothesised that acetated Ringer's and starch solution, alone or in combination, influence these mechanisms differently. On different occasions, 10 male volunteers were infused with 20 ml/kg acetated Ringer's and 10 ml/kg 6% hyroxyethyl starch 130/0.4 (Voluven(®) ) alone or in combination (first with starch solution followed by Ringer's solution). Blood samples were collected every 30-min for measurements of COP, blood haemoglobin, platelets, and plasma concentrations of albumin, immunoglobulins (IgG and IgM), coagulation factor VII (FVII), fibrinogen, cystatin C, activated partial thromboplastin time (APTT) and prothrombin international normalised ratio (PT-INR). Changes were compared with the haemoglobin-derived plasma dilution. The COP increased by 8.4% (SD 3) with starch and decreased by 26.2% (7.9) with Ringer's. These infusions diluted the plasma by 23.4% (5.3) and 18.7% (4.9) respectively. The COP changes in the combined experiment followed the same pattern as the individual infusions. Albumin and IgG changes in excess of the plasma dilution were very subtle. The intravascular contents of the IgM and platelets decreased, whereas FVII, fibrinogen and cystatin C increased. PT-INR increased by 1/3 of the plasma dilution, whereas changes in APTT did not correlate with the plasma dilution. The starch increased COP and only minor capillary leak occurred in healthy volunteers. The fluid-induced plasma dilution correlated with mild impairment of the extrinsic coagulation pathway but not of the intrinsic pathway. © 2015 The Acta Anaesthesiologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
NASA Astrophysics Data System (ADS)
Rao, T. Lakshmana; Pradhan, M. K.; Ramakrishna, P. V.; Dash, S.
2018-05-01
Modified-PZT ceramics with a formula Pb0.9Ni0.1[(Zr0.52Ti0.48)]1-xSnxO3 located near the morphotropic phase boundary (MPB) were prepared by conventional solid state process to investigate effects of dilute doping of Ni and Sn in different sites of PZT. The single phase structure of the series of samples has been identified by x-ray diffraction technique. The optical band gap has been obtained from the UV-Vis spectra and found to be shrinkage with doping. The detail dielectric and impedance studies are being carried out to investigate the conduction mechanism of the samples. A significant enhancement in the electric polarization is observed for the maximum Sn doping in a modified PZT.
Liao, Benjamin S; Sram, Jacqueline C; Files, Darin J
2013-01-01
A simple and effective anion ion chromatography (IC) method with anion exchange column and conductivity detector has been developed to determine free sulfites (SO3-2) in dried fruits processed with sulfur dioxide. No oxidation agent, such as hydrogen peroxide, is used to convert sulfites to sulfates for IC analysis. In addition, no stabilizing agent, such as formaldehyde, fructose or EDTA, is required during the sample extraction. This method uses aqueous 0.2 N NaOH as the solvent for standard preparation and sample extraction. The sulfites, either prepared from standard sodium sulfite powder or extracted from food samples, are presumed to be unbound SO3-2 in aqueous 0.2 N NaOH (pH > 13), because the bound sulfites in the sample matrix are released at pH > 10. In this study, sulfites in the standard solutions were stable at room temperature (i.e., 15-25 degrees C) for up to 12 days. The lowest standard of the linear calibration curve is set at 1.59 microg/mL SO3-2 (equivalent to 6.36 microg/g sample with no dilution) for analysis of processed dried fruits that would contain high levels (>1000 microg/g) of sulfites. As a consequence, this method typically requires significant dilution of the sample extract. Samples are prepared with a simple procedure of sample compositing, extraction with aqueous 0.2 N NaOH, centrifugation, dilution as needed, and filtration prior to IC. The sulfites in these sample extracts are stable at room temperature for up to 20 h. Using anion IC, the sulfites are eluted under isocratic conditions with 10 mM aqueous sodium carbonate solution as the mobile phase passing through an anion exchange column. The sulfites are easily separated, with an analysis run time of 18 min, regardless of the dried fruit matrix. Recoveries from samples spiked with sodium sulfites were demonstrated to be between 81 and 105% for five different fruit matrixes (apricot, golden grape, white peach, fig, and mango). Overall, this method is simple to perform and effective for the determination of high levels of sulfites in dried fruits.
Hussain, Muhammad Barkaat; Hannan, Abdul; Akhtar, Naeem; Fayyaz, Ghulam Qadir; Imran, Muhammad; Saleem, Sidrah; Qureshi, Imtiaz Ahmed
2015-02-26
The development of resistance to conventional anti-typhoid drugs and the recent emergence of fluoroquinolone resistance have made it very difficult and expensive to treat typhoid fever. As the therapeutic strategies become even more limited, it is imperative to investigate non-conventional modalities. In this context, honey is a potential candidate for combating antimicrobial resistance because it contains a broad repertoire of antibacterial compounds which act synergistically at multiple sites, thus making it less likely that the bacteria will become resistant. The in vitro antibacterial activity of 100 unifloral honey samples against a blood culture isolate of multi-drug resistant (MDR) Salmonella typhi were investigated. All honey samples were evaluated for both total (acidity, osmolarity, hydrogen peroxide and non-peroxide activity) and plant derived non-peroxide antibacterial activity by agar well diffusion assay at 50% and 25% dilution in sterile distilled water and 25% in catalase solution. Manuka (Unique Manuka Factor-21) honey was used for comparison. The phenol equivalence of each honey sample from 2% to 7% (w/v) phenol was obtained from regression analysis. The antibacterial potential of each honey sample was expressed as its equivalent phenol concentration. The honey samples which showed antibacterial activity equivalent to or greater than manuka honey were considered therapeutically active honeys. Nineteen honey samples (19%) displayed higher hydrogen peroxide related antibacterial activity (16-20% phenol), which is more than that of manuka honey (21-UMF). A total of 30% of the honey samples demonstrated antibacterial activity between 11 and 15% phenol similar to that of manuka honey while 51% of the honey samples did not exhibit any zone of inhibition against MDR-S. typhi at 50% (w/v) dilution. None of the indigenous honey samples displayed non-peroxide antibacterial activity. Only manuka honey showed non-peroxide antibacterial activity at 25% dilution (w/v) in catalase solution. The honey samples which displayed antibacterial activity equal to or greater than manuka honey may be useful in the clinical conditions where higher hydrogen peroxide related antibacterial activity is required. Manuka honey, which is known to possess non-peroxide antibacterial activity, warrants further evaluation in a suitable typhoid animal model.
Casas, I; Althouse, G C
2013-02-01
The holding time (HT) is the period during which an ejaculate, either in a raw or diluted state, is held at 17°C before further processing for cold-storage. In boars, the HT positively influences select sperm quality parameters of semen cooled from 15 to 5°C, a range in temperature during which plasma membrane remodeling occurs. Objective insight into the effect of HT on plasma membrane organization remains unknown. Therefore, the present work sought to elucidate if HT contributes to minimizing alterations in boar sperm plasma membrane fluidity at the initial step of the cooling process in a cryopreservation practice (holding at 5°C) and in relation with select sperm quality parameters. Nineteen ejaculates from five boars were collected and processed according to different treatments: T1) Fresh diluted semen, 0h at 17°C; T2) Fresh diluted semen, 24h at 17°C (HT); T3) Sperm from T1 in a lactose-egg yolk (LEY) extender, 3h at 5°C; T4) Sperm from T2 in LEY, 3h at 5°C; T5) Sperm from T1 in LEY, 24h at 5°C; T6) Sperm from T2 in LEY, 24h at 5°C. Sperm motility was assessed using CASA, and sperm plasma membrane integrity and fluidity were evaluated by flow cytometry with dual labeling (M540/YO-PRO®-1). Results demonstrated that the lack of exposure to a HT (T5) results in reduced sample motility compared to those having a HT (T6), with sperm exposed to HT exhibiting less plasma membrane fluidity. Collectively, these results provide empirical evidence that incorporation of a HT in semen processing protects boar sperm against cold injury through maintenance of lipid architecture of the plasma membrane. Copyright © 2012 Elsevier Inc. All rights reserved.
Measurement and validation of the nature of salivary adiponectin.
Akuailou, Eleonore-N; Vijayagopal, Parakat; Imrhan, Victorine; Prasad, Chandan
2013-10-01
Adiponectin (Ad) is an adipocyte-derived hormone that plays an essential role in regulating insulin sensitivity, inflammation, and atherogenesis. Levels of some hormones in saliva change in a fashion similar to that in plasma in response to a disease or physiological condition. Since saliva is an easy to obtain biological fluid, measurements of salivary hormonal changes are preferred in diagnoses and treatments. Therefore, it was of interest to examine the nature of salivary Ad. While there have been two publications in the literature reporting presence of Ad in human saliva, the nature of salivary Ad has not been characterized. To this end, we investigated the effect of sample dilution on the measurement of Ad in saliva. To our surprise, we observed an increase in measurable level of Ad in saliva on sample dilution. One explanation for this paradoxical observation may be the presence of inhibitor(s) of Ad/anti-Ad binding in saliva that following dilution relieves the inhibitory effect. Working with this hypothesis, we were able to demonstrate the presence of an inhibitor in saliva that co-eluted with the dimeric form of Ad and was capable of inhibiting Ad assay. The presence of such inhibitor(s) may lead to underestimation of Ad in saliva.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Selvan, J.S.; Subramanian, K.; Nath, A.K.
Surface nitriding of commercially pure (CP) titanium was carried out using high power CO{sub 2} laser at pure nitrogen and dilute nitrogen (N{sub 2} + Ar) environment. The hardness, microstructure, and melt pool configuration of the laser melted titanium in helium and argon atmosphere was compared with laser melting at pure and dilute nitrogen environment. The hardness of the nitrided layer was of the order of 1000 to 1600 HV. The hardness of the laser melted titanium in the argon and helium atmosphere was 500 to 1000 HV. Using x-ray analysis of the formation of TiN and Ti{sub 2}N phasemore » was identified in the laser nitrided titanium. The presence of nitrogen in the nitrided zone was confirmed using secondary ion mass spectroscopy (SIMS) analysis. The microstructures revealed densely populated dendrites in the sample nitrided at 100% N{sub 2} environment and thinly populated dendrites in dilute environment. The crack intensity was large in the nitrided sample at pure nitrogen, and few cracks were observed in the 50% N{sub 2} + 50% Ar environment.« less
Riboflavin and ultraviolet light reduce the infectivity of Babesia microti in whole blood.
Tonnetti, Laura; Thorp, Aaron M; Reddy, Heather L; Keil, Shawn D; Goodrich, Raymond P; Leiby, David A
2013-04-01
Babesia microti is the parasite most frequently transmitted by blood transfusion in the United States. Previous work demonstrated the efficacy of riboflavin (RB) and ultraviolet (UV) light to inactivate B.microti in apheresis plasma and platelet units. In this study we investigated the effectiveness of RB and UV light to reduce the levels of B.microti in whole blood (WB). WB units were spiked with B. microti-infected hamster blood. Spearman-Karber methods were used to calculate infectivity of each sample in terms of hamster infectious dose 50% (HID50 ) value. After RB addition, the units were illuminated with 80 J/mLRBC UV light. Two samples were collected: one before illumination and one after illumination. The samples were serially diluted and dilutions injected into a group of five naive hamsters. Four weeks postinoculation (PI), blood was collected from the animals and evaluated by microscopic observation. One pilot study showed a good dose response in the animals and demonstrated that sample infectivity could be calculated in terms of an HID50 . Three additional replicates were performed in the same manner as the pilot study, but with fewer dilutions. Infectivity values were consistent between the experiments and were used to calculate log reduction. The posttreatment reduction of B. microti for all the experiments was more than 5 log. The data collected indicate that use of RB and UV is able to decrease the parasite load in WB units thus reducing the risk of transfusion-transmitted B. microti from blood components containing B. microti-infected RBCs. © 2012 American Association of Blood Banks.
Stochastic sampling effects in STR typing: Implications for analysis and interpretation.
Timken, Mark D; Klein, Sonja B; Buoncristiani, Martin R
2014-07-01
The analysis and interpretation of forensic STR typing results can become more complicated when reduced template amounts are used for PCR amplification due to increased stochastic effects. These effects are typically observed as reduced heterozygous peak-height balance and increased frequency of undetected alleles (allelic "dropout"). To investigate the origins of these effects, a study was performed using the AmpFlSTR(®) Identifiler Plus(®) and MiniFiler(®) kits to amplify replicates from a dilution series of NIST Human DNA Quantitation Standard (SRM(®) 2372A). The resulting amplicons were resolved and detected on two different genetic analyzer platforms, the Applied Biosystems 3130xL and 3500 analyzers. Results from our study show that the four different STR/genetic analyzer combinations exhibited very similar peak-height ratio statistics when normalized for the amount of template DNA in the PCR. Peak-height ratio statistics were successfully modeled using the Poisson distribution to simulate pre-PCR stochastic sampling of the alleles, confirming earlier explanations that sampling is the primary source for peak-height imbalance in reduced template dilutions. In addition, template-based pre-PCR sampling simulations also successfully predicted allelic dropout frequencies, as modeled by logistic regression methods, for the low-template DNA dilutions. We discuss the possibility that an accurately quantified DNA template might be used to characterize the linear signal response for data collected using different STR kits or genetic analyzer platforms, so as to provide a standardized approach for comparing results obtained from different STR/CE combinations and to aid in validation studies. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.
Kumar, Bharat; Crittenden, Scott R
2013-11-01
We demonstrate the ability to measure Stern potential and Debye length in dilute ionic solution with atomic force microscopy. We develop an analytic expression for the second harmonic force component of the capacitive force in an ionic solution from the linearized Poisson-Boltzmann equation. This allows us to calibrate the AFM tip potential and, further, obtain the Stern potential of sample surfaces. In addition, the measured capacitive force is independent of van der Waals and double layer forces, thus providing a more accurate measure of Debye length.
Trace determination of zinc by substoichiometric isotope dilution analysis
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandhya, D.; Priya, S.; Subramanian, M.O.S.
1996-09-01
A radiometric method based on substoichiometric isotope dilution analysis using 1,10-phenanthroline and a substoichiometric amount of eosin was developed for determining trace amounts of zinc. Evaluation of various metal ion interferences shows that as little as 0.2 {mu}g Zn could be determined in an aqueous-phase volume of 60 mL. The method has been successfully applied to the determination of Zn in city waste incineration ash, cadmium metal, Fourts-B tablets, Boro-plus ointment, and magnesium alloy samples. 12 refs., 3 figs., 3 tabs.
Pollet-Villard, Marie; Cartier, Régine; Gaucherand, Pascal; Doret, Muriel
2011-06-01
We compared two biochemical tests of premature rupture of membranes (PROM) in vitro: Actim PROM (Medix Biochemica, Kauniainen, Finland), which detects insulin-like growth factor binding protein-1, and AmniSure (AmniSure International LLC, Cambridge, MA), which detects placental alpha microglobulin-1. Samples of amniotic fluid were collected during caesarean section in 41 patients. A dilution series was prepared and both tests were performed twice at each dilution. Sensitivity, detection limit, response time, and reproducibility of both tests were compared. Both tests' sensitivity was 100% at dilution 1:10 and 1:20. AmniSure sensitivity was higher at dilution 1:40 and 1:80 ( P < 0.05). In 29 of 40 cases, AmniSure had a lower detection limit than Actim PROM. AmniSure response times were shorter and reproducibility was higher than Actim PROM ( P < 0.05). AmniSure had a lower detection limit of amniotic fluid than Actim PROM, with a shorter response time, a higher sensitivity, and a better reproducibility. © Thieme Medical Publishers.
Wali, Nadia; Mirza, Irfan Ali
2016-04-01
To compare the in vitro efficacy of doripenem and imipenem against multi-drug resistant (MDR) Pseudomonas aeruginosa from various clinical specimens. Descriptive cross-sectional study. Department of Microbiology, Armed Forces Institute of Pathology, Rawalpindi, from November 2012 to November 2013. MDR Pseudomonas aeruginosa isolates from various clinical samples were included in the study. Susceptibility of Pseudomonas aeruginosa against doripenem and imipenem was performed by E-test strip and agar dilution methods. The results were interpreted as recommended by Clinical Laboratory Standard Institute (CLSI) guidelines. The maximum number of Pseudomonas aeruginosa were isolated from pure pus and pus swabs. In vitro efficacy of doripenem was found to be more effective as compared to imipenem against MDR Pseudomonas aeruginosa with both E-test strip and agar dilution methods. Overall, p-values of 0.014 and 0.037 were observed when susceptibility patterns of doripenem and imipenem were evaluated with E-test strip and agar dilution methods. In vitro efficacy of doripenem was found to be better against MDR Pseudomonas aeruginosaas compared to imipenem when tested by both E-test and agar dilution methods.
Characterisation of chlorophyll a solubilised in sodium lauryl sulphate micelles
NASA Astrophysics Data System (ADS)
Mukherjee, T.; Sapre, A. V.; Mittal, Jai P.
1980-01-01
Poisson statistics has been applied to the problem of solubilisation of chlorophyll a in sodium lauryl sulphate micelles. Dilution experiments have been carried out to support the finding that each unit of chlorophyll a contributing to the 740 nm band contains just one chlorophyll a molecule.
17 CFR 229.506 - (Item 506) Dilution.
Code of Federal Regulations, 2010 CFR
2010-04-01
... disparity between the public offering price and the effective cash cost to officers, directors, promoters... offering and the effective cash contribution of such persons. In such cases, and in other instances where... amount of the increase in such net tangible book value per share attributable to the cash payments made...
Changes in key aroma compounds of Criollo cocoa beans during roasting.
Frauendorfer, Felix; Schieberle, Peter
2008-11-12
Application of a comparative aroma extraction dilution analysis on unroasted and roasted Criollo cocoa beans revealed 42 aroma compounds in the flavor dilution (FD) factor range of 1-4096 for the unroasted and 4-8192 for the roasted cocoa beans. While the same compounds were present in the unroasted and roasted cocoa beans, respectively, these clearly differed in their intensity. For example, 2- and 3-methylbutanoic acid (rancid) and acetic acid (sour) showed the highest FD factors in the unroasted beans, while 3-methylbutanal (malty), 4-hydroxy-2,5-dimethyl-3(2H)-furanone (caramel-like), and 2- and 3-methylbutanoic acid (sweaty) were detected with the highest FD factors in the roasted seeds. Quantitation of 30 odorants by means of stable isotope dilution assays followed by a calculation of odor activity values (ratio of the concentration/odor threshold) revealed concentrations above the odor threshold for 22 compounds in the unroasted and 27 compounds in the roasted cocoa beans, respectively. In particular, a strong increase in the concentrations of the Strecker aldehydes 3-methylbutanal and phenylacetaldehyde as well as 4-hydroxy-2,5-dimethyl-3(2H)-furanone was measured, suggesting that these odorants should contribute most to the changes in the overall aroma after roasting. Various compounds contributing to the aroma of roasted cocoa beans, such as 3-methylbutanoic acid, ethyl 2-methylbutanoate, and 2-phenylethanol, were already present in unroasted, fermented cocoa beans and were not increased during roasting.
Abass, Kasim Sakran
2014-01-01
Organophosphate compounds can bind to carboxylesterase, which may lower the concentration of organophosphate pesticides at the target site enzyme, cholinesterase. It is unclear from the literature whether it is the carboxylesterase affinity for the organophosphate and/or the number of carboxylesterase molecules that is the dominant factor in determining the protective potential of carboxylesterase. The fundamental dilutions and kinetic effects of esterase enzyme are still poorly understood. This study aims to confirm and extend our current knowledge about the effects of dilutions on esterases activities in the blood for birds with respect to protecting the enzyme from organophosphate inhibition. There was significantly higher esterases activities in dilution 1 : 10 in the all blood samples from quail, duck, and chick compared to other dilutions (1 : 5, 1 : 15, 1 : 20, and 1 : 25) in all cases. Furthermore, our results also pointed to the importance of estimating different dilutions effects prior to using in birds as biomarker tools of environmental exposure. Concentration-inhibition curves were determined for the inhibitor in the presence of dilutions 1 : 5, 1 : 10, plus 1 : 15 (to stimulate carboxylesterase). Point estimates (concentrations calculated to produce 20, 50, and 80% inhibition) were compared across conditions and served as a measure of esterase-mediated detoxification. Results with well-known inhibitors (malathion) were in agreement with the literature, serving to support the use of this assay. Among the thiol-esters dilution 1 : 5 was observed to have the highest specificity constant (k cat/K m), and the K m and k cat values were 176 μM and 16,765 s−1, respectively, for S-phenyl thioacetate ester, while detected in dilution 1 : 15 was the lowest specificity constant (k cat/K m), and the K m and k cat values were 943 μM and 1154 s−1, respectively, for acetylthiocholine iodide ester. PMID:24864243
Method and apparatus for nitrogen oxide determination
Hohorst, Frederick A.
1990-01-01
Method and apparatus for determining nitrogen oxide content in a high temperature process gas, which involves withdrawing a sample portion of a high temperature gas containing nitrogen oxide from a source to be analyzed. The sample portion is passed through a restrictive flow conduit, which may be a capillary or a restriction orifice. The restrictive flow conduit is heated to a temperature sufficient to maintain the flowing sample portion at an elevated temperature at least as great as the temperature of the high temperature gas source, to thereby provide that deposition of ammonium nitrate within the restrictive flow conduit cannot occur. The sample portion is then drawn into an aspirator device. A heated motive gas is passed to the aspirator device at a temperature at least as great as the temperature of the high temperature gas source. The motive gas is passed through the nozzle of the aspirator device under conditions sufficient to aspirate the heated sample portion through the restrictive flow conduit and produce a mixture of the sample portion in the motive gas at a dilution of the sample portion sufficient to provide that deposition of ammonium nitrate from the mixture cannot occur at reduced temperature. A portion of the cooled dilute mixture is then passed to analytical means capable of detecting nitric oxide.
NASA Astrophysics Data System (ADS)
Wolfe, Gordon V.; Levasseur, Maurice; Cantin, Guy; Michaud, Sonia
2000-12-01
We adapted the dilution technique to study microzooplankton grazing of algal dimethylsulfoniopropionate (DMSP) vs. Chl a, and to estimate the impact of microzooplankton grazing on dimethyl sulfide (DMS) production in the Labrador Sea. Phytoplankton numbers were dominated by autotrophic nanoflagellates in the Labrador basin, but diatoms and colonial Phaeocystis pouchetii contributed significantly to phytomass at several high chlorophyll stations and on the Newfoundland and Greenland shelfs. Throughout the region, growth of algal Chl a and DMSP was generally high (0.2-1 d -1), but grazing rates were lower and more variable, characteristic of the early spring bloom period. Production and consumption of Chl a vs. DMSP followed no clear pattern, and sometimes diverged greatly, likely because of their differing distributions among algal prey taxa and size class. In several experiments where Phaeocystis was abundant, we observed DMS production proportional to grazing rate, and we found clear evidence of DMS production by this haptophyte following physical stress such as sparging or filtration. It is possible that grazing-activated DMSP cleavage by Phaeocystis contributes to grazer deterrence: protozoa and copepods apparently avoided healthy colonies (as judged by relative growth and grazing rates of Chl a and DMSP), and grazing of Phaeocystis was significant only at one station where cells were in poor condition. Although we hoped to examine selective grazing on or against DMSP-containing algal prey, the dilution technique cannot differentiate selective ingestion and varying digestion rates of Chl a and DMSP. We also found that the dilution method alone was poorly suited for assessing the impact of grazing on dissolved sulfur pools, because of rapid microbial consumption and the artifactual release of DMSP and DMS during filtration. Measuring and understanding the many processes affecting organosulfur cycling by the microbial food web in natural populations remain a technical challenge that will likely require a combination of techniques to address.
England, Glenn C; Watson, John G; Chow, Judith C; Zielinska, Barbara; Chang, M C Oliver; Loos, Karl R; Hidy, George M
2007-01-01
With the recent focus on fine particle matter (PM2.5), new, self-consistent data are needed to characterize emissions from combustion sources. Such data are necessary for health assessment and air quality modeling. To address this need, emissions data for gas-fired combustors are presented here, using dilution sampling as the reference. The dilution method allows for collection of emitted particles under conditions simulating cooling and dilution during entry from the stack into the air. The sampling and analysis of the collected particles in the presence of precursor gases, SO2 nitrogen oxide, volatile organic compound, and NH3 is discussed; the results include data from eight gas fired units, including a dual-fuel institutional boiler and a diesel engine powered electricity generator. These data are compared with results in the literature for heavy-duty diesel vehicles and stationary sources using coal or wood as fuels. The results show that the gas-fired combustors have very low PM2.5 mass emission rates in the range of approximately 10(-4) lb/million Btu (MMBTU) compared with the diesel backup generator with particle filter, with approximately 5 x 10(-3) lb/MMBTU. Even higher mass emission rates are found in coal-fired systems, with rates of approximately 0.07 lb/MMBTU for a bag-filter-controlled pilot unit burning eastern bituminous coal. The characterization of PM2.5 chemical composition from the gas-fired units indicates that much of the measured primary particle mass in PM2.5 samples is organic or elemental carbon and, to a much less extent, sulfate. Metal emissions are quite low compared with the diesel engines and the coal- or wood-fueled combustors. The metals found in the gas-fired combustor particles are low in concentration, similar in concentration to ambient particles. The interpretation of the particulate carbon emissions is complicated by the fact that an approximately equal amount of particulate carbon (mainly organic carbon) is found on the particle collector and a backup filter. It is likely that measurement artifacts, mostly adsorption of volatile organic compounds on quartz filters, are positively biasing "true" particulate carbon emission results.
Soto-Muñoz, Lourdes; Teixidó, Neus; Usall, Josep; Viñas, Inmaculada; Crespo-Sempere, Ana; Torres, Rosario
2014-06-16
Dilution plating is the quantification method commonly used to estimate the population level of postharvest biocontrol agents, but this method does not permit a distinction among introduced and indigenous strains. Recently, molecular techniques based on DNA amplification such as quantitative real-time PCR (qPCR) have been successfully applied for their high strain-specific detection level. However, the ability of qPCR to distinguish viable and nonviable cells is limited. A promising strategy to avoid this issue relies on the use of nucleic acid intercalating dyes, such as propidium monoazide (PMA), as a sample pretreatment prior to the qPCR. The objective of this study was to optimize a protocol based on PMA pre-treatment samples combined with qPCR to distinguish and quantify viable cells of the biocontrol agent P. agglomerans CPA-2 applied as a postharvest treatment on orange. The efficiency of PMA-qPCR method under the established conditions (30μM PMA for 20min of incubation followed by 30min of LED light exposure) was evaluated on an orange matrix. Results showed no difference in CFU or cells counts of viable cells between PMA-qPCR and dilution plating. Samples of orange matrix inoculated with a mixture of viable/dead cells showed 5.59log10 CFU/ml by dilution plating, 8.25log10 cells/ml by qPCR, and 5.93log10 cells/ml by PMA-qPCR. Furthermore, samples inoculated with heat-killed cells were not detected by dilution plating and PMA-qPCR, while by qPCR was of 8.16log10 cells/ml. The difference in quantification cycles (Cq) among qPCR and PMA-qPCR was approximately 16cycles, which means a reduction of 65,536 fold of the dead cells detected. In conclusion, PMA-qPCR method is a suitable tool for quantify viable CPA-2 cells, which could be useful to estimate the ability of this antagonist to colonize the orange surface. Copyright © 2014 Elsevier B.V. All rights reserved.
Code of Federal Regulations, 2013 CFR
2013-07-01
... detector (HFID) (375 °±20 °F (191 °±11 °C)) sample for total hydrocarbon (THC) analysis. The HFID sample... integrated measurement of diluted THC is required. Unless compensation for varying mass flow is made, a constant mass flow system must be used to ensure a proportional THC measurement. (2) For natural gas-fueled...
Code of Federal Regulations, 2012 CFR
2012-07-01
... detector (HFID) (375 °±20 °F (191 °±11 °C)) sample for total hydrocarbon (THC) analysis. The HFID sample... integrated measurement of diluted THC is required. Unless compensation for varying mass flow is made, a constant mass flow system must be used to ensure a proportional THC measurement. (2) For natural gas-fueled...
40 CFR 86.1540 - Idle exhaust sample analysis.
Code of Federal Regulations, 2013 CFR
2013-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission... the CVS sampling system is used, the analysis procedures for dilute CO and CO2 specified in 40 CFR part 1065 apply. Follow the raw CO2 analysis procedure specified in 40 CFR part 1065, subpart F, for...
40 CFR 86.1540 - Idle exhaust sample analysis.
Code of Federal Regulations, 2014 CFR
2014-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES Emission Regulations for... CVS sampling system is used, the analysis procedures for dilute CO and CO2 specified in 40 CFR part 1065 apply. Follow the raw CO2 analysis procedure specified in 40 CFR part 1065, subpart F, for the raw...
40 CFR 86.1540 - Idle exhaust sample analysis.
Code of Federal Regulations, 2012 CFR
2012-07-01
... (CONTINUED) CONTROL OF EMISSIONS FROM NEW AND IN-USE HIGHWAY VEHICLES AND ENGINES (CONTINUED) Emission... the CVS sampling system is used, the analysis procedures for dilute CO and CO2 specified in 40 CFR part 1065 apply. Follow the raw CO2 analysis procedure specified in 40 CFR part 1065, subpart F, for...
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2011 CFR
2011-07-01
... filter and HFID. Determine these gas temperatures by a temperature sensor located immediately upstream of... analytical system description. (a) General. The exhaust gas sampling system described in this section is...-CVS must conform to all of the requirements listed for the exhaust gas PDP-CVS in § 90.420 of this...
40 CFR 90.421 - Dilute gaseous exhaust sampling and analytical system description.
Code of Federal Regulations, 2010 CFR
2010-07-01
... filter and HFID. Determine these gas temperatures by a temperature sensor located immediately upstream of... analytical system description. (a) General. The exhaust gas sampling system described in this section is...-CVS must conform to all of the requirements listed for the exhaust gas PDP-CVS in § 90.420 of this...
EFFECTS OF RESIDUAL ORGANIC MATTER ON ELEMENTAL ANALYSES BY SPARK SOURCE MASS SPECTROGRAPHY (SSMS)
The report gives results of research to define the effect of organics in SSMS and to evaluate several sample preparation methods for their removal. Samples of known organic content were fabricated by diluting NBS SRM 1633 fly ash (spiked with several trace elements) with a mixtur...
40 CFR 86.135-94 - Dynamometer procedure.
Code of Federal Regulations, 2011 CFR
2011-07-01
... in bags are analyzed for THC, CO, CO2, CH4 and NOX. For petroleum-fueled diesel-cycle vehicles...), THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel samples of the dilution air are similarly analyzed for THC, CO, CO2, CH4 and NOX. For natural gas-fueled...
40 CFR 86.135-94 - Dynamometer procedure.
Code of Federal Regulations, 2010 CFR
2010-07-01
... in bags are analyzed for THC, CO, CO2, CH4 and NOX. For petroleum-fueled diesel-cycle vehicles...), THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel samples of the dilution air are similarly analyzed for THC, CO, CO2, CH4 and NOX. For natural gas-fueled...
40 CFR 86.135-94 - Dynamometer procedure.
Code of Federal Regulations, 2013 CFR
2013-07-01
... in bags are analyzed for THC, CO, CO2, CH4 and NOX. For petroleum-fueled diesel-cycle vehicles...), THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel samples of the dilution air are similarly analyzed for THC, CO, CO2, CH4 and NOX. For natural gas-fueled...
40 CFR 86.135-94 - Dynamometer procedure.
Code of Federal Regulations, 2012 CFR
2012-07-01
... in bags are analyzed for THC, CO, CO2, CH4 and NOX. For petroleum-fueled diesel-cycle vehicles...), THC is sampled and analyzed continuously according to the provisions of § 86.110. Parallel samples of the dilution air are similarly analyzed for THC, CO, CO2, CH4 and NOX. For natural gas-fueled...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beeck, T., E-mail: torben.beeck@desy.de; Baev, I.; Gieschen, S.
2016-04-15
A new ultra-low temperature experiment including a superconducting vector magnet has been developed for soft x-ray absorption spectroscopy experiments at third generation synchrotron light sources. The sample is cooled below 50 mK by a cryogen free {sup 3}He-{sup 4}He dilution refrigerator. At the same time, magnetic fields of up to ±7 T in the horizontal direction and ±0.5 T in the vertical direction can be applied by a superconducting vector magnet. The setup allows to study ex situ and in situ prepared samples, offered by an attached UHV preparation chamber with load lock. The transfer of the prepared samples betweenmore » the preparation section and the dilution refrigerator is carried out under cryogenic temperatures. First commissioning studies have been carried out at the Variable Polarization XUV Beamline P04 at PETRA III and the influence of the incident photon beam to the sample temperature has been studied.« less
Spectrometric Analysis for Pulse Jet Mixer Testing
DOE Office of Scientific and Technical Information (OSTI.GOV)
ZEIGLER, KRISTINE
2004-07-12
The Analytical Development Section (ADS) was tasked with providing support for a Hanford River Protection Program-Waste Treatment Program (RPP-WTP) project test involving absorption analysis for non-Newtonian pulse jet mixer testing for small scale (PJM) and prototype (CRV) tanks with sparging. Tanks filled with clay were mixed with various amounts of powdered dye as a tracer. The objective of the entire project was to determine the best mixing protocol (nozzle velocity, number of spargers used, total air flow, etc.) by determining the percent mixed volume through the use of an ultraviolet-visible (UV-Vis) spectrometer. The dye concentration within the sample could bemore » correlated to the volume fraction mixed in the tank. Samples were received in vials, a series of dilutions were generated from the clay, allowed to equilibrate, then centrifuged and siphoned for the supernate liquid to analyze by absorption spectroscopy. Equilibration of the samples and thorough mixing of the samples were a continuous issue with dilution curves being difficult to obtain. Despite these technical issues, useful data was obtained for evaluation of various mix conditions.« less
Thom, I; Cameron, G; Robertson, D; Watson, H G
2018-05-02
Rivaroxaban concentrations were measured in 127 inpatient samples using an HPLC-MS/MS assay. We compared this measurement with a calibrated anti-Xa assay and performed PT, aPTT and dilute PT tests to assess the value of clot-based assays in clinical decision-making. The correlation between the anti-Xa assay and the HPLC-MS/MS at therapeutic concentrations was strong (R 2 = 0.98). The PT, RecombiPlasTin 2G, and aPTT, Actin FS, showed a linear dose-response but poor correlation (R 2 = 0.32 and 0.44, respectively) and at dilutions of 1 in 150 to 1 in 750 the dilute PT assay also showed poor correlation with rivaroxaban concentrations measured by specific assays. A normal PT or aPTT alone did not identify a likely safe rivaroxaban concentration to allow surgery or invasive procedures, but the combination of normal PT and aPTT identified a group of patients with rivaroxaban levels less than 90 ng/mL. Combined normal PT and aPTT had specificity and sensitivity of 0.97 (95% CI 0.92-0.99) and 0.37 (95% CI 0.1-0.74) for a rivaroxaban concentration < 32 ng/mL. The PT and aPTT show poor correlation with rivaroxaban levels measured by calibrated anti-Xa and HPLC-MS/MS assays. A normal combined PT and APTT identified low rivaroxaban levels with high specificity but lacked sensitivity. The dPT assay at several dilutions could not be used to quantify rivaroxaban in clinical samples. The utility of these PT, aPTT and dilute PT assays in a clinical setting is very limited, and results generated must be interpreted with caution. © 2018 John Wiley & Sons Ltd.
Kim, Dianne H; Stark, Walter J; O'Brien, Terrence P; Dick, James D
2005-11-01
To measure the achievable perioperative aqueous concentration of the commercially available topically administered fourth generation fluoroquinolones, moxifloxacin 0.5% ophthalmic solution, and gatifloxacin 0.3% ophthalmic solution, and to correlate this concentration with the agents' biological efficacy in the aqueous humor of patients undergoing routine cataract surgery. Prospective, randomized, parallel, double-masked, clinical trial. Fifty patients undergoing cataract extraction. Patients (n = 25) were given perioperative topical moxifloxacin 0.5% or topical gatifloxacin 0.3% (n = 25). One drop of antibiotic was administered every 10 minutes for 4 doses beginning 1 hour prior to surgery. Aqueous humor was sampled via paracentesis and antibiotic concentrations were determined using validated high performance liquid chromatography (HPLC) procedures. Dilution analyses were performed to determine the biological efficacy of the agents in the aqueous against Staphylococcus epidermidis, the most common cause of postcataract endophthalmitis. Aqueous humor antibiotic concentrations were measured using HPLC and microdilution bioassay techniques. Biological activity was measured as minimal inhibitory dilution and minimal bactericidal dilution. Aqueous humor concentrations for moxifloxacin via HPLC analysis were 1.80 (+/-1.21) microg/ml, whereas those for gatifloxacin were 0.48 (+/-0.34) microg/ml. This 3.8-fold difference in aqueous humor antibiotic concentrations was statistically significant (P = 0.00003). Similarly, the biological dilution analysis of the aqueous humor samples showed that moxifloxacin attained an estimated activity of 2.1 microg/ml, whereas the gatifloxacin activity was approximately 0.4 mug/ml, which represented a 4.9-fold difference. This study demonstrated that after topically administered perioperative antibiotics with cataract surgery, moxifloxacin 0.5% ophthalmic solution achieved a statistically significantly higher concentration in aqueous humor compared with gatifloxacin (P = 0.00003). Results from the broth dilution analysis showed that moxifloxacin 0.5% was biologically more active against S. epidermidis than gatifloxacin 0.3% in aqueous humor after topical application. There were no adverse events reported, and incision wounds healed quickly and as expected.
NASA Astrophysics Data System (ADS)
Pierce, J. R.; Kreidenweis, S. M.; Bian, Q.; Jathar, S.; Kodros, J.; Barsanti, K.; Hatch, L. E.; May, A.
2017-12-01
Secondary organic aerosol (SOA) has been shown to form in biomass-burning emissions in laboratory and field studies. However, there is significant variability among studies in mass enhancement, which could be due to differences in fuels, fire conditions, dilution, and/or limitations of laboratory experiments and observations. This study focuses on understanding processes affecting biomass-burning SOA formation in ambient plumes. The plume dilution rate impacts the organic partitioning between the gas and particle phases, which may impact the potential for SOA to form as well as the rate of SOA formation. We use an aerosol microphysics model that includes representations of volatility and oxidation chemistry to estimate SOA formation in the smoke emitted into the atmosphere. We add Gaussian dispersion to our aerosol microphysical model to estimate how SOA formation may vary under different ambient-plume conditions (e.g. fire size, emission mass flux, atmospheric stability). Smoke from small fires, such as typical prescribed burns, dilutes rapidly, which drives evaporation of organic vapor from the particle phase, leading to more effective SOA formation. Emissions from large fires, such as intense wildfires, dilute slowly, suppressing OA evaporation and subsequent SOA formation in the near field. We also demonstrate that different approaches to the calculation of OA enhancement in ambient plumes can lead to different conclusions regarding SOA formation. Normalized OA mass enhancement ratios of around 1 calculated using an inert tracer, such as black carbon or CO, have traditionally been interpreted as exhibiting little or no SOA formation; however, we show that SOA formation may have greatly contributed to the mass in these plumes.
Using GC×GC-ToF-MS to characterise SVOC from diesel exhaust emissions
NASA Astrophysics Data System (ADS)
Alam, M. S.; Ramadhas, A. S.; Stark, C. P.; Liu, D.; Xu, H.; Harrison, R. M.
2014-12-01
Despite intensive research over the last 20 years, a number of major research questions remain concerning the sources and properties of road traffic-generated particulate matter. There are major knowledge gaps concerning the composition of primary vehicle exhaust aerosol, and its contribution to secondary organic aerosol (SOA) formation. These uncertainties relate especially to the semi-volatile component of the particles. Semi-Volatile Organic Compounds (SVOC) are compounds which partition directly between the gas and aerosol phases under ambient conditions, and include compounds with saturation concentrations roughly between 0.1 and 104 μg m-3. The SVOC in engine exhaust are typically hydrocarbons in the C15-C35 range. They are largely uncharacterised, other than the n-alkanes, because they are unresolved by traditional gas chromatography and form a large hump in the chromatogram referred to as Unresolved Complex Mixture (UCM). In this study, samples were collected from the exhaust of a diesel engine with and without abatement devices fitted. Engine exhaust was diluted with air and collected using both filter and impaction (MOUDI), to resolve total mass and size resolved mass respectively. Particle size distribution was evaluated by sampling simultaneously with a Scanning Mobility Particle Sizer (SMPS). 2D Gas-Chromatography Time-of-Flight Mass-Spectrometry (GC×GC-ToF-MS) was exploited to characterise and quantify the composition of SVOC from the exhaust emission. The SVOC was observed to contain predominantly n-alkanes, alkyl-cyclohexanes and aromatics; similar to both fresh lubricating oil and fuel. Preliminary results indicate that the contribution of diesel fuel to the exhaust SVOC composition is dominant at high speeds, and a more pronounced contribution from lubricating oil is observed at low speeds. Differences were also observed in the SVOC composition when using different fuel types, engine lubricants, starting temperatures and collecting samples with and without abatement devices fitted. The wealth of compounds identified and quantified in the C15-C35 range included PAH, esters, carboxylic acids, alkanes, alkenes, alcohols and hopanes.
Sampling and detection of airborne influenza virus towards point-of-care applications.
Ladhani, Laila; Pardon, Gaspard; Meeuws, Hanne; van Wesenbeeck, Liesbeth; Schmidt, Kristiane; Stuyver, Lieven; van der Wijngaart, Wouter
2017-01-01
Airborne transmission of the influenza virus contributes significantly to the spread of this infectious pathogen, particularly over large distances when carried by aerosol droplets with long survival times. Efficient sampling of virus-loaded aerosol in combination with a low limit of detection of the collected virus could enable rapid and early detection of airborne influenza virus at the point-of-care setting. Here, we demonstrate a successful sampling and detection of airborne influenza virus using a system specifically developed for such applications. Our system consists of a custom-made electrostatic precipitation (ESP)-based bioaerosol sampler that is coupled with downstream quantitative polymerase chain reaction (qPCR) analysis. Aerosolized viruses are sampled directly into a miniaturized collector with liquid volume of 150 μL, which constitutes a simple and direct interface with subsequent biological assays. This approach reduces sample dilution by at least one order of magnitude when compared to other liquid-based aerosol bio-samplers. Performance of our ESP-based sampler was evaluated using influenza virus-loaded sub-micron aerosols generated from both cultured and clinical samples. Despite the miniaturized collection volume, we demonstrate a collection efficiency of at least 10% and sensitive detection of a minimum of 3721 RNA copies. Furthermore, we show that an improved extraction protocol can allow viral recovery of down to 303 RNA copies and a maximum sampler collection efficiency of 47%. A device with such a performance would reduce sampling times dramatically, from a few hours with current sampling methods down to a couple of minutes with our ESP-based bioaerosol sampler.
Mineralization and nitrification patterns at eight northeastern USA forested research sites
Ross, D.S.; Lawrence, G.B.; Fredriksen, G.
2004-01-01
Nitrogen transformation rates in eight northeastern US research sites were measured in soil samples taken in the early season of 2000 and the late season of 2001. Net mineralization and nitrification rates were determined on Oa or A horizon samples by two different sampling methods - intact cores and repeated measurements on composite samples taken from around the cores. Net rates in the composite samples (n=30) showed three different temporal patterns: high net nitrification with minimal NH4+ accumulation, high net nitrification and high NH4+ accumulation, and minimal net nitrification and moderate NH4+ accumulation. The 4-week net rates in intact cores were about half that of the rates from the composite samples but were well related (R2 > 0.70). Composite samples from sites that exhibited high net nitrification were incubated with acetylene and net nitrification was completely stopped, suggesting an autotrophic pathway. Gross mineralization and nitrification (2000 only) rates were estimated using the isotope dilution technique. Gross rates of nitrification and consumption in intact cores were relatively low. Gross rates of mineralization and net rates of nitrification were both related to the soil C/N ratio, with higher rates generally occurring in sites containing Acer saccharum as a dominant or co-dominant species. The comparison of methods suggests that all provide a similar hierarchy of potential rates but that the degree of net nitrification is strongly influenced by the degree of sample disturbance. Differences between sites appear to be related to an interaction of soil (C/N) and vegetation (A. saccharum contribution) characteristics. ?? 2003 Elsevier B.V. All rights reserved.
Jessner, W; Watkins-Riedel, T; Müller, C; Formann, E; Gschwantler, M; Ferenci, P
2007-11-01
Prediction of treatment response is clinically important in chronic hepatitis C virus (HCV) genotype 4 infection. Early viral kinetics is useful in this respect for genotype 1 but interpretation is dependent on assay linearity and reproducibility. The VERSANT HCV RNA 3.0 (bDNA-3.0) and the COBAS Amplicor HCV Monitor 2.0 (HCM-2.0) have been widely used quantitative assays. We wanted to comparatively evaluate the two tests in a large genotype 4 sample. Genotyping was performed by NS5b sequencing. Viral load was tested in parallel in 32 patients at least six times on antiviral therapy with interferon alpha (IFNalpha). Totally, 198 samples within a quantitative range from undetectable to about 7 x 10(6) IU/mL (bDNA-3.0) were obtained and compared. Twenty-two samples with viral load above 500 000 IU/mL tested by HCM-2.0 were 1:100 diluted and retested. Quantitative values were fitted to a third order polynomial (M = 0.118303 + 1.07503 x V+ 0.0112128 x V(2) - 0.0055504 x V(3); M...HCM-2.0, V...bDNA-3.0, both log IU/mL) showing progressive nonlinearity of HCM-2.0 above 100 000 IU/mL but better clinical sensitivity with respect to bDNA-3.0. Dilution lead to a gain of at least a factor of 2.7 and thus, overestimation compared with bDNA-3.0. Deviation from linearity and overestimation upon dilution by HCM-2.0 are similar with HCV genotype 4, compared with other HCV genotypes. Differences in test performance were not detected for subtypes but for individual patients possibly related to specific quasi-species patterns. The interpretation of viral kinetic data becomes difficult due to overestimation upon dilution of baseline values by HCM-2.0.
Evaluation of metal loading to streams near Creede, Colorado, August and September 2000
Kimball, B.A.; Runkel, R.L.; Walton-Day, K.; Stover, B.K.
2006-01-01
Decisions about remediation of mine drainage on the watershed scale require an understanding of metal contributions from all sources to be able to choose the best sites for remediation. A hydrologic framework to study metal loading in the Willow Creek watershed, a tributary to the Rio Grande River, was established by conducting a series of tracer-injection studies. Each study used the tracer-dilution method in conjunction with synoptic sampling to determine the spatial distribution of discharge and concentration. Discharge and concentration data were then used to develop mass-loading curves for the metals of interest. The discharge and load profiles (1) identify the principal sources of load to the streams; (2) demonstrate the scale of unsampled, dispersed subsurface inflows; and (3) estimate the amount of natural attenuation. The greatest source of metal loads was from the Nelson Tunnel on West Willow Creek, which contributed 158 kilograms per day of zinc to the stream. Additional loading from other dispersed, subsurface inflows along West Willow Creek added substantial loads, but these were small in comparison to the loads from the Nelson Tunnel. No significant contributions of metal load from potential sources occurred along East Willow Creek. The lack of measurable loading may be a result of previous remedial actions along that stream. The lower Willow Creek section had relatively small contributions of load compared to what had been contributed upstream. This watershed approach provides a detailed snapshot of metal load for the watershed to support remediation decisions and quantifies processes that affect metal transport.
Simonich, Staci Massey; Sun, Ping; Casteel, Ken; Dyer, Scott; Wernery, Dave; Garber, Kevin; Carr, Gregory; Federle, Thomas
2013-10-01
The risks of 1,4-dioxane (dioxane) concentrations in wastewater treatment plant (WWTP) effluents, receiving primarily domestic wastewater, to downstream drinking water intakes was estimated using distributions of measured dioxane concentrations in effluents from 40 WWTPs and surface water dilution factors of 1323 drinking water intakes across the United States. Effluent samples were spiked with a d8 -1,4-dioxane internal standard in the field immediately after sample collection. Dioxane was extracted with ENVI-CARB-Plus solid phase columns and analyzed by GC/MS/MS, with a limit of quantification of 0.30 μg/L. Measured dioxane concentrations in domestic wastewater effluents ranged from <0.30 to 3.30 μg/L, with a mean concentration of 1.11 ± 0.60 μg/L. Dilution of upstream inputs of effluent were estimated for US drinking water intakes using the iSTREEM model at mean flow conditions, assuming no in-stream loss of dioxane. Dilution factors ranged from 2.6 to 48 113, with a mean of 875. The distributions of dilution factors and dioxane concentration in effluent were then combined using Monte Carlo analysis to estimate dioxane concentrations at drinking water intakes. This analysis showed the probability was negligible (p = 0.0031) that dioxane inputs from upstream WWTPs could result in intake concentrations exceeding the USEPA drinking water advisory concentration of 0.35 μg/L, before any treatment of the water for drinking use. © 2013 SETAC.
Yan, Yaping; Ao, Lei; Wang, Hong; Duan, Yanchao; Chang, Shaohui; Chen, Bingbing; Zhi, Dalong; Li, Sujuan; Niu, Yuyu; Ji, Weizhi; Si, Wei
2016-11-01
Conventional TRISegg yolk (TEY) freezing medium for the cryopreservation of NHP sperm has the risk of contamination due to widespread zoonotic diseases. This study was aimed at determining the optimal glycerol concentration, freezing rate, and holding time in liquid N2 vapor for the cryopreservation of cynomolgus macaque sperm by using a commercial egg-yolkfree freezing medium (SC medium) designed for human sperm cryopreservation. Sperm motility and acrosomal integrity after freezing were assessed. Sperm in SC medium (dilution ratio, 3:1) frozen at cooling rates of 67 and 183C/min in liquid N2 vapor showed higher post-thaw motility than did samples frozen at 435C/min. At the cooling rate of 183C/min and dilution in SC medium at a 3:1 ratio, post-thaw motility was higher after a holding time of 10 min than after 30 min (recommended by the manufacturer). In addition, post-thaw motility of sperm frozen in SC medium was higher with dilution ratios of 3:1, 4.5:1, and 6:1 compared with 9:1, 10.5:1, and 12:1, and the sample diluted 12:1 showed the lowest percentage of thawed sperm with intact acrosomes. Sperm showed higher post-thaw motility after freezing in TEY than in SC medium; acrosomal integrity did not differ between the 2 media. Our results indicated that cynomolgus macaque sperm can be cryopreserved successfully by using a commercial egg-yolkfree freezing medium, which provides an option for genetic preservation with decreased zoonotic risk in this important NHP species.
Urine specimen validity test for drug abuse testing in workplace and court settings.
Lin, Shin-Yu; Lee, Hei-Hwa; Lee, Jong-Feng; Chen, Bai-Hsiun
2018-01-01
In recent decades, urine drug testing in the workplace has become common in many countries in the world. There have been several studies concerning the use of the urine specimen validity test (SVT) for drug abuse testing administered in the workplace. However, very little data exists concerning the urine SVT on drug abuse tests from court specimens, including dilute, substituted, adulterated, and invalid tests. We investigated 21,696 submitted urine drug test samples for SVT from workplace and court settings in southern Taiwan over 5 years. All immunoassay screen-positive urine specimen drug tests were confirmed by gas chromatography/mass spectrometry. We found that the mean 5-year prevalence of tampering (dilute, substituted, or invalid tests) in urine specimens from the workplace and court settings were 1.09% and 3.81%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the workplace were 89.2%, 6.8%, and 4.1%, respectively. The mean 5-year percentage of dilute, substituted, and invalid urine specimens from the court were 94.8%, 1.4%, and 3.8%, respectively. No adulterated cases were found among the workplace or court samples. The most common drug identified from the workplace specimens was amphetamine, followed by opiates. The most common drug identified from the court specimens was ketamine, followed by amphetamine. We suggest that all urine specimens taken for drug testing from both the workplace and court settings need to be tested for validity. Copyright © 2017. Published by Elsevier B.V.
Felizardo, V O; Mello, R A; Murgas, L D S; Andrade, E S; Drumond, M M; Rosa, P V
2010-12-01
This study investigated the application of intra- and extra-cellular cryoprotectant combinations on the quality of curimba Prochilodus lineatus semen subjected to cryopreservation. Semen treatments were tested with 8% DMSO or methanol as intracellular cryoprotectant, 5% egg yolk or lactose as extracellular cryoprotectant and 5% BTS. These cryoprotectant combinations are suitable for curimba but have not been tested at the lesser concentrations proposed or in combination with BTS. Semen samples collected from 19 curimbas were diluted into one of four cryoprotectant combinations: DMSO+yolk; DMSO+lactose; methanol+yolk; and methanol+lactose. After dilution, semen samples were cryopreserved in 0.5 mL straws for 10 days in a liquid nitrogen tank. Semen was thawed in a water bath at 60°C for 8s. We evaluated the quality of fresh, diluted (pre-freezing) and post-freezing semen according to sperm motility rate (%) and duration (s). Sperm morphology was also analyzed in thawed semen. Sperm motility rate decreased progressively after dilution and thawing. The motility rate in post-freezing semen was higher in the treatments using DMSO+lactose and methanol+yolk. Sperm motility duration in post-freezing sperm was greater in the treatments using methanol rather than DMSO as intracellular cryoprotectant, irrespective of the extracellular cryoprotectant used. Abnormality frequency in thawed sperm was less in semen treated with egg yolk than with lactose. Thus the use of methanol intracellular cryoprotectant is recommended along with yolk extracellular cryoprotectant in the cryopreservation process for curimba semen. Copyright © 2010 Elsevier B.V. All rights reserved.
Accurate Determination of Soluble Axl by Enzyme-Linked Immunosorbent Assay.
Dengler, Mirko; Huber, Heidemarie; Müller, Christian J; Zellmer, Angela; Rauch, Peter; Mikulits, Wolfgang
2016-11-01
Levels of soluble Axl (sAxl) are routinely assessed in human sera by sandwich enzyme-linked immunosorbent assay (ELISA). Although sAxl values are suggested to diagnose different types of disorders, no uniform ELISA method is available, allowing the reliable interassay comparison between results. Furthermore, little is known about the stability of sAxl under storage conditions, which is a relevant parameter for biomedical trials. The evaluation of sAxl stability under various stress conditions and the determination of proper conditions to use the sAxl ELISA for routine clinical applications are of great interest. In this study, serum samples were subjected to freeze-thaw cycles and incubation at different temperatures to analyze the stability of sAxl by ELISA. Dilution and spike-in experiments were carried out to examine the impact of serum and diluent components on the ELISA performance. Various diluents and media were employed to resolve masking effects of the serum. The assay components were further optimized for long-term usability by treatment with stabilizers and validation under temperature stress. Indeed, sAxl showed long-term stability in serum during freeze-thaw cycles and incubation under temperature stress conditions. The dilution experiments revealed that unknown components in the serum caused masking effects that can be reduced by proper dilutions. The assay performance was further increased by using a standardized buffer system to dilute serum samples. Stabilization of coated plates and of streptavidin-horseradish peroxidase allowed long-term storage for up to 6 months. In sum, our data demonstrate proper ELISA conditions, allowing the accurate analysis of sAxl levels in human serum.
Iwasa, Megumi; Nakaya, Satoshi; Maki, Yusuke; Marumoto, Shinsuke; Usami, Atsushi; Miyazawa, Mitsuo
2015-01-01
The chemical composition of essential oil extracted from Uncaria Hook ("Chotoko" in Japanese), the branch with curved hook of the herbal medicine Uncaria rhynchophylla has been investigated by GC and GC-MS analyses. Eighty-four compounds, representing 90.8% of the total content was identified in oil obtained from Uncaria Hook. The main components i were (E)-cinnamaldehyde (13.4%), α-copaene (8.0%), methyl eugenol (6.8%), δ-cadinene (5.3%), and curcumene (3.6%). The important key aroma-active compounds in the oil were detected by gas chromatography-olfactometry (GC-O) and aroma extract dilution analysis (AEDA), using the flavor dilution (FD) factor to express the odor potency of each compounds. Furthermore, the odor activity value (OAV) has been used as a measure of the relative contribution of each compound to the aroma of the Uncaria Hook oil. The GC-O and AEDA results showed that α-copaene (FD = 4, OAV = 4376), (E)-linalool oxide (FD = 64, OAV = 9.1), and methyl eugenol (FD = 64, OAV = 29) contributed to the woody and spicy odor of Uncaria Hook oil, whereas furfural (FD = 8, OAV = 4808) contributed to its sweet odor. These results warrant further investigations of the application of essential oil from Uncaria Hook in the phytochemical and medicinal fields.
Magnetization and photomagnetic effects in diluted magnetic microcrystalline Cd 1-xMn xTe
NASA Astrophysics Data System (ADS)
He, X.-F.; Kotlicki, A.; Dosanjh, P.; Turrell, B. G.; Carolan, J. F.; Jimenez-Sandoval, S.; Lozano-Tovar, P.
1993-12-01
We have investigated the magnetic and photomagnetic properties of microcrystalline Cd 1-xMn xTe prepared by rf sputtering. Magnetization measurements were carried out using an rf SQUID magnetometer in the temperature range of 1.8 to 300 K at various magnetic fields up to 5.5 T. For temperatures above 40 K, the sample showed Curie-Weiss behaviour with a Curie temperature indicating predominantly antiferromagnetic interactions. A spin-glass phase transition was also observed. Photomagnetization measurements were performed using a fibre-optic system. The light was shone onto the sample utilizing an optical fibre and the subsequent change in the magnetization was sensed by the SQUID. Photo-induced magnetization was observed when the sample was illuminated by unpolarized light. Our results enable qualitative and quantitative conclusions to be drawn on the magnetic behaviour and the interplay between optical and magnetic properties of the diluted magnetic microcrystalline semiconductors. PACS: 68.55.Gi; 75.50.Pp.
Creation of 0.10-cm-1 resolution quantitative infrared spectral libraries for gas samples
NASA Astrophysics Data System (ADS)
Sharpe, Steven W.; Sams, Robert L.; Johnson, Timothy J.; Chu, Pamela M.; Rhoderick, George C.; Guenther, Franklin R.
2002-02-01
The National Institute of Standards and Technology (NIST) and the Pacific Northwest National Laboratory (PNNL) are independently creating quantitative, approximately 0.10 cm-1 resolution, infrared spectral libraries of vapor phase compounds. The NIST library will consist of approximately 100 vapor phase spectra of volatile hazardous air pollutants (HAPs) and suspected greenhouse gases. The PNNL library will consist of approximately 400 vapor phase spectra associated with DOE's remediation mission. A critical part of creating and validating any quantitative work involves independent verification based on inter-laboratory comparisons. The two laboratories use significantly different sample preparation and handling techniques. NIST uses gravimetric dilution and a continuous flowing sample while PNNL uses partial pressure dilution and a static sample. Agreement is generally found to be within the statistical uncertainties of the Beer's law fit and less than 3 percent of the total integrated band areas for the 4 chemicals used in this comparison. There does appear to be a small systematic difference between the PNNL and NIST data, however. Possible sources of the systematic difference will be discussed as well as technical details concerning the sample preparation and the procedures for overcoming instrumental artifacts.
Tertiary carbonate-dissolution cycles on the Sierra Leone Rise, eastern equatorial Atlantic Ocean
Dean, W.E.; Gardner, J.V.; Cepek, P.
1981-01-01
Most of the Tertiary section on Sierra Leone Rise off northwest Africa consists of chalk, marl, and limestone that show cyclic alterations of clay-rich and clay-poor beds about 20-60 cm thick. On the basis of biostratigraphic accumulation rates, the cycles in Oligocene and Miocene chalk have periods which average about 44,000 years, and those in Eocene siliceous limestone have periods of 4000-27,000 years. Several sections were sampled in detail to further define the cycles in terms of content of CaCO3, clay minerals, and relative abundances of calcareous nannofossils. Extending information gained by analyses of Pleistocene cores from the continental margin of northwest Africa to the Tertiary cycles on Sierra Leone Rise, both dilution by noncarbonate material and dissolution of CaCO3 could have contributed to the observed relative variations in clay and CaCO3. However, dissolution of CaCO3 as the main cause of the carbonate-clay cycles on the Sierra Leone Rise, rather than dilution by clay, is suggested by the large amount of change (several thousand percent) in terrigenous influx required to produce the observed variations in amount of clay and by the marked increase in abundance of dissolution-resistant discoasters relative to more easily dissolved coccoliths in low-carbonate parts of cycles. The main cause of dissolution of CaCO3 was shoaling of the carbonate compensation depth (CCD) during the early Neogene and climatically induced fluctuations in the thickness of Antarctic Bottom Water. ?? 1981.
A new approach for flow-through respirometry measurements in humans
Ingebrigtsen, Jan P.; Bergouignan, Audrey; Ohkawara, Kazunori; Kohrt, Wendy M.; Lighton, John R. B.
2010-01-01
Indirect whole room calorimetry is commonly used in studies of human metabolism. These calorimeters can be configured as either push or pull systems. A major obstacle to accurately calculating gas exchange rates in a pull system is that the excurrent flow rate is increased above the incurrent flow rate, because the organism produces water vapor, which also dilutes the concentrations of respiratory gasses in the excurrent sample. A common approach to this problem is to dry the excurrent gasses prior to measurement, but if drying is incomplete, large errors in the calculated oxygen consumption will result. The other major potential source of error is fluctuations in the concentration of O2 and CO2 in the incurrent airstream. We describe a novel approach to measuring gas exchange using a pull-type whole room indirect calorimeter. Relative humidity and temperature of the incurrent and excurrent airstreams are measured continuously using high-precision, relative humidity and temperature sensors, permitting accurate measurement of water vapor pressure. The excurrent flow rates are then adjusted to eliminate the flow contribution from water vapor, and respiratory gas concentrations are adjusted to eliminate the effect of water vapor dilution. In addition, a novel switching approach is used that permits constant, uninterrupted measurement of the excurrent airstream while allowing frequent measurements of the incurrent airstream. To demonstrate the accuracy of this approach, we present the results of validation trials compared with our existing system and metabolic carts, as well as the results of standard propane combustion tests. PMID:20200135
DOE Office of Scientific and Technical Information (OSTI.GOV)
Malik, Afshan N., E-mail: afshan.malik@kcl.ac.uk; Shahni, Rojeen; Rodriguez-de-Ledesma, Ana
2011-08-19
Highlights: {yields} Mitochondrial dysfunction is central to many diseases of oxidative stress. {yields} 95% of the mitochondrial genome is duplicated in the nuclear genome. {yields} Dilution of untreated genomic DNA leads to dilution bias. {yields} Unique primers and template pretreatment are needed to accurately measure mitochondrial DNA content. -- Abstract: Circulating mitochondrial DNA (MtDNA) is a potential non-invasive biomarker of cellular mitochondrial dysfunction, the latter known to be central to a wide range of human diseases. Changes in MtDNA are usually determined by quantification of MtDNA relative to nuclear DNA (Mt/N) using real time quantitative PCR. We propose that themore » methodology for measuring Mt/N needs to be improved and we have identified that current methods have at least one of the following three problems: (1) As much of the mitochondrial genome is duplicated in the nuclear genome, many commonly used MtDNA primers co-amplify homologous pseudogenes found in the nuclear genome; (2) use of regions from genes such as {beta}-actin and 18S rRNA which are repetitive and/or highly variable for qPCR of the nuclear genome leads to errors; and (3) the size difference of mitochondrial and nuclear genomes cause a 'dilution bias' when template DNA is diluted. We describe a PCR-based method using unique regions in the human mitochondrial genome not duplicated in the nuclear genome; unique single copy region in the nuclear genome and template treatment to remove dilution bias, to accurately quantify MtDNA from human samples.« less
Gas nanobubbles and aqueous nanostructures: the crucial role of dynamization.
Demangeat, Jean-Louis
2015-04-01
Nanobubbles (NBs) have been a subject of intensive research over the past decade. Their peculiar characteristics, including extremely low buoyancy, longevity, enhanced solubility of oxygen in water, zeta potentials and burst during collapse, have led to many applications in the industrial, biological and medical fields. NBs may form spontaneously from dissolved gas but the process is greatly enhanced by gas supersaturation and mechanical actions such as dynamization. Therefore, the formation of NBs during the preparation of homeopathic dilutions under atmospheric pressure cannot be ignored. I suggested in 2009 the involvement of NBs in nanometric superstructures revealed in high dilutions using NMR relaxation. These superstructures seemed to increase in size with dilution, well into the ultramolecular range (>12c). I report here new experiments that confirm the involvement of NBs and prove the crucial role of dynamization to create superstructures specific to the solute. A second dynamization was shown to enhance or regenerate these superstructures. I postulate that superstructures result from a nucleation process of NBs around the solute, with shells of highly organized water (with ions and silicates if any) which protect the solute against out-diffusion and behave as nucleation centres for further dilution steps. The sampling tip may play an active role by catching the superstructures and thus carry the encaged solute across the dilution range, possibly up to the ultramolecular range. The superstructures were not observed at low dilution, probably because of a destructuring of the solvent by the solute and/or of an inadequate gas/solute ratio. Copyright © 2015 The Faculty of Homeopathy. Published by Elsevier Ltd. All rights reserved.
Clarke, R N; Sexton, T J; Ottinger, M A
1982-09-01
A series of experiments was conducted to measure the respiratory activity, motility, and fertility of chicken and turkey sperm in undiluted and diluted (1 part semen to 5 parts Beltsville Poultry Semen Extender) semen held at either 41, 25, 15, or 5 C for 3 or 6 hr. Sperm respiration was temperature dependent, increasing with increasing temperature. When incubated under identical conditions, the respiratory rate of spermatozoa in diluted semen of both species was significantly (P less than .05) higher than in undiluted semen. In undiluted and diluted chicken and turkey semen, sperm mortality was lowest at 41 C. No differences in the motility of spermatozoa from undiluted and diluted semen of either species were observed in the unstored controls. Sperm motility in samples held at 15 or 5 C was similar to that of the unstored controls. The fertility of diluted chicken semen was highest (75%) after 6 hr of storage at 5 C. Fertility levels (71 to 83%) of chicken semen was highest (75%) after 6 hr of storage at 5 C. Fertility levels (71 to 83%) of chicken semen held for 3 hr at 25, 15, or 5 C did not differ from the unstored control. In contrast, the fertilizing capacity of diluted turkey semen (0 to 45%) was significantly lower than the unstored controls (68%), regardless of holding times and temperatures. The fertility of undiluted turkey semen was significantly (P less than .05) lower than the unstored control in all cases, with the exception of semen held at 25 C for 3 hr.
Albrecht, Nathalie A; Howard, Judith; Kovacevic, Alan; Adamik, Katja N
2016-07-26
The artificial colloid, hydroxyethyl starch (HES), is recommended for intravascular volume expansion and colloid-osmotic pressure enhancement in dogs and cats. A well-known side effect of HES solutions in humans and dogs is coagulopathy. However, HES-associated coagulopathy has thus far not been investigated in cats. The goal of this study was to assess the in vitro effects of 6 % HES 130/0.42 on feline whole blood samples using rotational thromboelastometry (ROTEM). A further goal was to develop feline reference intervals for ROTEM at our institution. In this in vitro experimental study, blood samples of 24 adult healthy cats were collected by atraumatic jugular phlebotomy following intramuscular sedation. Baseline ROTEM analyses (using ex-tem, in-tem and fib-tem assays) were performed in duplicate. Additionally, ROTEM analyses were performed on blood samples after dilution with either Ringer's acetate (RA) or 6 % HES 130/0.42 (HES) in a 1:6 dilution (i.e. 1 part solution and 6 parts blood). Coefficients of variation of duplicate measures were below 12 % in all ex-tem assays, 3 of 4 in-tem assays but only 1 of 3 fib-tem assays. Reference intervals were similar albeit somewhat narrower than those previously published. Dilution with both solutions lead to significantly prolonged CT (in-tem), CFT (ex-tem and in-tem), and reduced MCF (ex-tem, in-tem, and fib-tem) and alpha (ex-tem and in-tem). Compared to RA, dilution with HES caused a significant prolongation of CT in fib-tem (P = 0.016), CFT in ex-tem (P = 0.017) and in-tem (P = 0.019), as well as a reduction in MCF in in-tem (P = 0.032) and fib-tem (P = 0.020), and alpha in ex-tem (P = 0.014). However, only a single parameter (CFT in ex-tem) was outside of the established reference interval after dilution with HES. In vitro hemodilution of feline blood with RA and HES causes a small but significant impairment of whole blood coagulation, with HES leading to a significantly greater effect on coagulation than RA. Further studies are necessary to evaluate the in vivo effects and the clinical significance of these findings.
Changes in pectins and product consistency during the concentration of tomato juice to paste.
Anthon, Gordon E; Diaz, Jerome V; Barrett, Diane M
2008-08-27
Concentrating tomato juice to paste during the tomato season allows for preservation and long-term storage, but subsequent dilution for formulation of value-added products is known to result in a loss of consistency. To understand the reasons for this, samples of unconcentrated juice, processing intermediates, and concentrated paste were collected from an industrial processing plant during normal commercial production. All samples were diluted with water to 5 degrees Brix and then analyzed for consistency and pectin content. Whole juice consistency, measured with a Bostwick consistometer, decreased through the course of juice concentration, with the largest change occurring early in the process, as the juice was concentrated from 5 to 10 degrees Brix. This decrease in consistency occurred during the production of paste from both hot- and cold-break juices. The change in Bostwick value was correlated with a decrease in the precipitate weight ratio. The loss of consistency during commercial processing was not the direct result of water removal because a sample of this same 5 degrees Brix juice could be concentrated 2-fold in a vacuum oven and then diluted back to 5 degrees Brix with no change in consistency or precipitate ratio. Total pectin content did not change as the juice was concentrated to paste, but the proportion of the total pectin that was water soluble increased. The greatest increases in pectin solubility occurred during the hot break and late in the process where the evaporator temperature was the highest.
Origin of Tungsten Excess in Komatiites
NASA Astrophysics Data System (ADS)
Becker, H.; Brandon, A. D.; Walker, R. J.
2004-12-01
The limited database available for W abundances in komatiites (n=7, Newsom et al., 1996) suggests that when melting and fractional crystallization effects are filtered out, these komatiites have about 10 times higher W, compared to other mantle-derived mafic-ultramafic magmas (MORB, OIB). The excess of W in the komatiites relative to lithophile highly incompatible elements becomes obvious when compared with the low concentrations of the light REE Ce and Nd (about 1-2 ug/g in many komatiites, compared to > 10 ug/g in most MORB and OIB). In order to increase the komatiite W database, komatiite samples from Phanerozoic (Gorgona Island) and Archean terraines (Boston Creek/Canada, Belingwe/South Africa, 2.7 Ga) were dissolved and W was separated in order to obtain W concentrations by isotope dilution. Except for one sample from Gorgona Island with low W (23 ng/g), samples from all three locales show high W (516 to 2643 ng/g), with most samples containing near 700 ng/g W. Three Hawaiian picrites (H23, LO-02-04, MK-1-6) were also analyzed for comparative purposes and contain 75, 163 and 418 ng/g W, respectively. The W concentrations in the Hawaiian picrites are comparable or lower than W concentrations in Hawaiian tholeiites (Newsom et al., 1996). Mass balance considerations suggest that it is unlikely that the W excess in komatiites reflects W contributions to the mantle sources of komatiites from the outer core. The W enrichment could result from shallow-level alteration processes if primary W abundances of komatiites were low and W was added via fluids, containing W and other fluid-mobile elements derived from crustal rocks. Because most W in such samples would be of crustal origin, small contributions from the outer core may be difficult to detect using 182W systematics (Schersten et al., 2003).
Curie temperatures of cubic (Ga, Mn)N diluted magnetic semiconductors from the RKKY spin model.
Zhu, Li-Fang; Liu, Bang-Gui
2009-11-04
We explore how much the RKKY spin interaction can contribute to the high-temperature ferromagnetism in cubic (Ga, Mn)N diluted magnetic semiconductors. The usual coupling constant is used and effective carriers are considered independent of doped magnetic atoms, as is shown experimentally. Our Monte Carlo simulated results show that maximal Curie temperature is reached at the optimal carrier concentration for a given Mn concentration, equaling 373 K for 5% Mn and 703 K for 8% Mn. Because such a Monte Carlo method does not overestimate transition temperatures, these calculations indicate that the RKKY spin interaction alone can yield high-enough Curie temperatures in cubic (Ga, Mn)N under optimized conditions.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Beavin, P. Jr.
A previously published method for determining zirconium in antiperspirant aerosols was collaboratively studied by 7 laboratories. The method consists of 2 procedures: a rapid dilution procedure for soluble zirconium compounds or a lengthier fusion procedure for total zirconium followed by colorimetric determination. The collaborators were asked to perform the following: Spiking materials representing 4 levels of soluble zirconium were added to weighed portions of a zirconium-free cream base concentrate and the portions were assayed by the dilution procedure. Spiking materials representing 4 levels of zirconium in either the soluble or the insoluble form (or as a mixture) were also addedmore » to portions of the same concentrate and these portions were assayed by the fusion procedure. They were also asked to concentrate and assay, by both procedures, 2 cans each of 2 commercial aerosol antiperspirants containing zirconyl hydroxychloride. The average percent recoveries and standard deviations for spiked samples were 99.8-100.2 and 1.69-2.71, respectively, for soluble compounds determined by the dilution procedure, and 93.8-97.4 and 3.09-4.78, respectively, for soluble and/or insoluble compounds determined by the fusion procedure. The average perent zirconium found by the dilution procedure in the 2 commercial aerosol products was 0.751 and 0.792. Insufficient collaborative results were received for the fusion procedure for statistical evaluation. The dilution procedure has been adopted as official first action.« less
Ackerman, S B; Kelley, E A
1983-01-01
The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units. Images PMID:6341399
Ackerman, S B; Kelley, E A
1983-03-01
The performance of a fiberoptic probe colorimeter (model PC800; Brinkmann Instruments, Inc., Westbury, N.Y.) for quantitating enzymatic or colorimetric assays in 96-well microtiter plates was compared with the performances of a spectrophotometer (model 240; Gilford Instrument Laboratories, Inc., Oberlin, Ohio) and a commercially available enzyme immunoassay reader (model MR590; Dynatech Laboratories, Inc., Alexandria, Va.). Alkaline phosphatase-p-nitrophenyl phosphate in 3 M NaOH was used as the chromophore source. Six types of plates were evaluated for use with the probe colorimeter; they generated reproducibility values (100% coefficient of variation) ranging from 91 to 98% when one individual made 24 independent measurements on the same dilution of chromophore on each plate. Eleven individuals each performed 24 measurements with the colorimeter on either a visually light (absorbance of 0.10 at 420 nm) or a dark (absorbance of 0.80 at 420 nm) dilution of chromophore; reproducibilities averaged 87% for the light dilution and 97% for the dark dilution. When one individual measured the same chromophore sample at least 20 times in the colorimeter, in the spectrophotometer or in the enzyme immunoassay reader, reproducibility for each instrument was greater than 99%. Measurements of a dilution series of chromophore in a fixed volume indicated that the optical responses of each instrument were linear in a range of 0.05 to 1.10 absorbance units.
Determination of 232Th in urine by ICP-MS for individual monitoring purposes.
Baglan, N; Cossonnet, C; Ritt, J
2001-07-01
Thorium is naturally occurring in various ores used for industrial purposes and has numerous applications. This paper sets out to investigate urine analysis as a suitable monitoring approach for workers potentially exposed to thorium. Due to its biokinetic behavior and its low solubility, urinary concentrations are generally very low, requiring therefore high sensitivity analytical methods. An analytical procedure has been developed for detecting 232Th concentrations of below 1 mBq L(-1) quickly and easily. Due to the long half-life (1.41 x 10(10) y) of 232Th, the potential of a procedure based on urine sample dilution and ICP-MS (inductively coupled plasma-mass spectrometry) measurement was investigated first. Two dilution factors were chosen: 100, which is more suitable for long-term measurement trials, and 20, which increases sensitivity. It has been shown that a 100-fold dilution can be used to measure concentrations of below 1 mBq L(-1), whereas a 20-fold one can be used to reach concentrations of below 0.06 mBq L(-1). Then, on the basis of the limitation of the procedure based on urine dilution, the suitable field of application for the different procedures (100-fold and 20-fold dilution and also a chemical purification followed by an ICP-MS measurement) was determined in relation to monitoring objectives.
Johnson, Raymond H.; Wirt, Laurie; Manning, Andrew H.; Leib, Kenneth J.; Fey, David L.; Yager, Douglas B.
2007-01-01
In San Juan County, Colo., the effects of historical mining continue to contribute metals to ground water and surface water. Previous research by the U.S. Geological Survey identified ground-water discharge as a significant pathway for the loading of metals to surface water in the upper Animas River watershed from both acid-mine drainage and acid-rock drainage. In support of this ground-water research effort, Prospect Gulch was selected for further study and the geochemistry of surface and ground water in the area was analyzed as part of four sampling plans: (1) ten streamflow and geochemistry measurements at five stream locations (four locations along Cement Creek plus the mouth of Prospect Gulch from July 2004 through August 2005), (2) detailed stream tracer dilution studies in Prospect Gulch and in Cement Creek from Gladstone to Georgia Gulch in early October 2004, (3) geochemistry of ground water through sampling of monitoring wells, piezometers, mine shafts, and springs, and (4) samples for noble gases and tritium/helium for recharge temperatures (recharge elevation) and ground-water age dating. This report summarizes all of the surface and ground-water data that was collected and includes: (1) all sample collection locations, (2) streamflow and geochemistry, (3) ground-water geochemistry, and (4) noble gas and tritium/helium data.