75 FR 8431 - Carbon Dioxide Fire Suppression Systems on Commercial Vessels
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-24
... Fire Suppression Systems on Commercial Vessels; Proposed Rule #0;#0;Federal Register / Vol. 75 , No. 36... 1625-AB44 Carbon Dioxide Fire Suppression Systems on Commercial Vessels AGENCY: Coast Guard, DHS... for fire suppression systems on several classes of commercial vessels. The amendments would clarify...
Operating room fire prevention: creating an electrosurgical unit fire safety device.
Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J
2014-08-01
To reduce the incidence of surgical fires. Operating room fires represent a potentially life-threatening hazard and are triggered by the electrosurgical unit (ESU) pencil. Carbon dioxide is a fire suppressant and is a routinely used medical gas. We hypothesize that a shroud of protective carbon dioxide covering the tip of the ESU pencil displaces oxygen, thereby preventing fire ignition. Using 3-dimensional modeling techniques, a polymer sleeve was created and attached to an ESU pencil. This sleeve was connected to a carbon dioxide source and directed the gas through multiple precisely angled ports, generating a cone of fire-suppressive carbon dioxide surrounding the active pencil tip. This device was evaluated in a flammability test chamber containing 21%, 50%, and 100% oxygen with sustained ESU activation. The sleeve was tested with and without carbon dioxide (control) until a fuel was ignited or 30 seconds elapsed. Time to ignition was measured by high-speed videography. Fires were ignited with each control trial (15/15 trials). The control group median ± SD ignition time in 21% oxygen was 3.0 ± 2.4 seconds, in 50% oxygen was 0.1 ± 1.8 seconds, and in 100% oxygen was 0.03 ± 0.1 seconds. No fire was observed when the fire safety device was used in all concentrations of oxygen (0/15 trials; P < 0.0001). The exact 95% confidence interval for absolute risk reduction of fire ignition was 76% to 100%. A sleeve creating a cone of protective carbon dioxide gas enshrouding the sparks from an ESU pencil effectively prevents fire in a high-flammability model. Clinical application of this device may reduce the incidence of operating room fires.
Fire suppression in human-crew spacecraft
NASA Technical Reports Server (NTRS)
Friedman, Robert; Dietrich, Daniel L.
1991-01-01
Fire extinguishment agents range from water and foam in early-design spacecraft (Halon 1301 in the present Shuttle) to carbon dioxide proposed for the Space Station Freedom. The major challenge to spacecraft fire extinguishment design and operations is from the micro-gravity environment, which minimizes natural convection and profoundly influences combustion and extinguishing agent effectiveness, dispersal, and post-fire cleanup. Discussed here are extinguishment in microgravity, fire-suppression problems anticipated in future spacecraft, and research needs and opportunities.
Spacecraft Fire Suppression: Testing and Evaluation
NASA Technical Reports Server (NTRS)
Abbud-Madrid, Angel; McKinnon, J. Thomas; Delplanque, Jean-Pierre; Kailasanath, Kazhikathra; Gokoglu, Suleyman; Wu, Ming-Shin
2004-01-01
The objective of this project is the testing and evaluation of the effectiveness of a variety of fire suppressants and fire-response techniques that will be used in the next generation of spacecraft (Crew Exploration Vehicle, CEV) and planetary habitats. From the many lessons learned in the last 40 years of space travel, there is common agreement in the spacecraft fire safety community that a new fire suppression system will be needed for the various types of fire threats anticipated in new space vehicles and habitats. To date, there is no single fire extinguishing system that can address all possible fire situations in a spacecraft in an effective, reliable, clean, and safe way. The testing conducted under this investigation will not only validate the various numerical models that are currently being developed, but it will provide new design standards on fire suppression that can then be applied to the next generation of spacecraft extinguishment systems. The test program will provide validation of scaling methods by conducting small, medium, and large scale fires. A variety of suppression methods will be tested, such as water mist, carbon dioxide, and nitrogen with single and multiple injection points and direct or distributed agent deployment. These injection methods cover the current ISS fire suppression method of a portable hand-held fire extinguisher spraying through a port in a rack and also next generation spacecraft units that may have a multi-point suppression delivery system built into the design. Consideration will be given to the need of a crew to clean-up the agent and recharge the extinguishers in flight in a long-duration mission. The fire suppression methods mentioned above will be used to extinguish several fire scenarios that have been identified as the most relevant to spaceflight, such as overheated wires, cable bundles, and circuit boards, as well as burning cloth and paper. Further testing will be conducted in which obstructions and ventilation will be added to represent actual spacecraft conditions (e.g., a series of cards in a card rack).
77 FR 33859 - Carbon Dioxide Fire Suppression Systems on Commercial Vessels
Federal Register 2010, 2011, 2012, 2013, 2014
2012-06-07
...-based systems under NFPA 12 and its wide and inexpensive availability. The success and availability of... because of the availability of better alternatives, and that we should ban gas- driven alarms and...
Determination of Survivable Fires
NASA Technical Reports Server (NTRS)
Dietrich, D. L.; Niehaus, J. E.; Ruff, G. A.; Urban, D. L.; Takahashi, F.; Easton, J. W.; Abbott, A. A.; Graf, J. C.
2012-01-01
At NASA, there exists no standardized design or testing protocol for spacecraft fire suppression systems (either handheld or total flooding designs). An extinguisher's efficacy in safely suppressing any reasonable or conceivable fire is the primary benchmark. That concept, however, leads to the question of what a reasonable or conceivable fire is. While there exists the temptation to over-size' the fire extinguisher, weight and volume considerations on spacecraft will always (justifiably) push for the minimum size extinguisher required. This paper attempts to address the question of extinguisher size by examining how large a fire a crew member could successfully survive and extinguish in the confines of a spacecraft. The hazards to the crew and equipment during an accidental fire include excessive pressure rise resulting in a catastrophic rupture of the vehicle skin, excessive temperatures that burn or incapacitate the crew (due to hyperthermia), carbon dioxide build-up or other accumulation of other combustion products (e.g. carbon monoxide). Estimates of these quantities are determined as a function of fire size and mass of material burned. This then becomes the basis for determining the maximum size of a target fire for future fire extinguisher testing.
Carbon Dioxide as a Fire Suppressant: Examining the Risks
Under the Clean Air Act Amendments of 1990, the U.S. Environmental Protection Agency (EPA) has the statutory authority to set phase-out dates for ozone-depleting substances (ODS) and to evaluate potential risks posed by proposed ODS substitutes.
Fire safety practices in the Shuttle and the Space Station Freedom
NASA Technical Reports Server (NTRS)
Friedman, Robert
1993-01-01
The Shuttle reinforces its policy of fire-preventive measures with onboard smoke detectors and Halon 1301 fire extinguishers. The forthcoming Space Station Freedom will have expanded fire protection with photoelectric smoke detectors, radiation flame detectors, and both fixed and portable carbon dioxide fire extinguishers. Many design and operational issues remain to be resolved for Freedom. In particular, the fire-suppression designs must consider the problems of gas leakage in toxic concentrations, alternative systems for single-failure redundancy, and commonality with the corresponding systems of the Freedom international partners. While physical and engineering requirements remain the primary driving forces for spacecraft fire-safety technology, there are, nevertheless, needs and opportunities for the application of microgravity combustion knowledge to improve and optimize the fire-protective systems.
NASA Technical Reports Server (NTRS)
Nahra, Henry (Compiler)
2004-01-01
Reports are presented from volume 2 of the conference titled Strategic Research to Enable NASA's Exploration Missions, poster session. Topics included spacecraft fire suppression and fire extinguishing agents,materials flammability, various topics on the effects of microgravity including crystal growth, fluid mechanics, electric particulate suspension, melting and solidification, bubble formation, the sloshing of liquid fuels, biological studies, separation of carbon dioxide and carbon monoxide for Mars ISRU.
Fine-Water-Mist Multiple-Orientation-Discharge Fire Extinguisher
NASA Technical Reports Server (NTRS)
Butz, James R.; Turchi, Craig S.; Kimball, Amanda; McKinnon, Thomas; Riedel, Edward
2010-01-01
A fine-water-mist fire-suppression device has been designed so that it can be discharged uniformly in any orientation via a high-pressure gas propellant. Standard fire extinguishers used while slightly tilted or on their side will not discharge all of their contents. Thanks to the new design, this extinguisher can be used in multiple environments such as aboard low-gravity spacecraft, airplanes, and aboard vehicles that may become overturned prior to or during a fire emergency. Research in recent years has shown that fine water mist can be an effective alternative to Halons now banned from manufacture. Currently, NASA uses carbon dioxide for fire suppression on the International Space Station (ISS) and Halon chemical extinguishers on the space shuttle. While each of these agents is effective, they have drawbacks. The toxicity of carbon dioxide requires that the crew don breathing apparatus when the extinguishers are deployed on the ISS, and Halon use in future spacecraft has been eliminated because of international protocols on substances that destroy atmospheric ozone. A major advantage to the new system on occupied spacecraft is that the discharged system is locally rechargeable. Since the only fluids used are water and nitrogen, the system can be recharged from stores of both carried aboard the ISS or spacecraft. The only support requirement would be a pump to fill the water and a compressor to pressurize the nitrogen propellant gas. This system uses a gaseous agent to pressurize the storage container as well as to assist in the generation of the fine water mist. The portable fire extinguisher hardware works like a standard fire extinguisher with a single storage container for the agents (water and nitrogen), a control valve assembly for manual actuation, and a discharge nozzle. The design implemented in the proof-of-concept experiment successfully extinguished both open fires and fires in baffled enclosures.
Carbon Dioxide Dispersion in the Combustion Integrated Rack Simulated Numerically
NASA Technical Reports Server (NTRS)
Wu, Ming-Shin; Ruff, Gary A.
2004-01-01
When discharged into an International Space Station (ISS) payload rack, a carbon dioxide (CO2) portable fire extinguisher (PFE) must extinguish a fire by decreasing the oxygen in the rack by 50 percent within 60 sec. The length of time needed for this oxygen reduction throughout the rack and the length of time that the CO2 concentration remains high enough to prevent the fire from reigniting is important when determining the effectiveness of the response and postfire procedures. Furthermore, in the absence of gravity, the local flow velocity can make the difference between a fire that spreads rapidly and one that self-extinguishes after ignition. A numerical simulation of the discharge of CO2 from PFE into the Combustion Integrated Rack (CIR) in microgravity was performed to obtain the local velocity and CO2 concentration. The complicated flow field around the PFE nozzle exits was modeled by sources of equivalent mass and momentum flux at a location downstream of the nozzle. The time for the concentration of CO2 to reach a level that would extinguish a fire anywhere in the rack was determined using the Fire Dynamics Simulator (FDS), a computational fluid dynamics code developed by the National Institute of Standards and Technology specifically to evaluate the development of a fire and smoke transport. The simulation shows that CO2, as well as any smoke and combustion gases produced by a fire, would be discharged into the ISS cabin through the resource utility panel at the bottom of the rack. These simulations will be validated by comparing the results with velocity and CO2 concentration measurements obtained during the fire suppression system verification tests conducted on the CIR in March 2003. Once these numerical simulations are validated, portions of the ISS labs and living areas will be modeled to determine the local flow conditions before, during, and after a fire event. These simulations can yield specific information about how long it takes for smoke and combustion gases produced by a fire to reach a detector location, how large the fire would be when the detector alarms, and the behavior of the fire until it has been extinguished. This new capability could then be used to optimize the location of fire detectors and fire-suppression ports as well as to evaluate the effectiveness of fire suppressants and response strategies. Numerical data collected from these simulations could also be used to develop a virtual reality fire event for crew training and fire safety awareness. This work is funded by NASA's Bioastronautics Initiative, which has the objective of ensuring and enhancing the health, safety, and performance of humans in space. As part of this initiative, the Microgravity Combustion Science Branch at the NASA Glenn Research Center is conducting spacecraft fire safety research to significantly improve fire safety on inhabited spacecraft.
46 CFR 147.65 - Carbon dioxide and halon fire extinguishing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 5 2010-10-01 2010-10-01 false Carbon dioxide and halon fire extinguishing systems. 147... dioxide and halon fire extinguishing systems. (a) Carbon dioxide or halon cylinders forming part of a...) Carbon dioxide or halon cylinders must be rejected for further service when they— (1) Leak; (2) Are...
46 CFR 147.65 - Carbon dioxide and halon fire extinguishing systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 5 2014-10-01 2014-10-01 false Carbon dioxide and halon fire extinguishing systems. 147... dioxide and halon fire extinguishing systems. (a) Carbon dioxide or halon cylinders forming part of a...) Carbon dioxide or halon cylinders must be rejected for further service when they— (1) Leak; (2) Are...
Isolated Liquid Droplet Combustion: Inhibition and Extinction Studies
NASA Technical Reports Server (NTRS)
Dryer, F. L.; Kroenlein, K. G.; Kazakov, A.; Williams, F. A.; Nayagam, V.
2004-01-01
Introduction of fire suppressants to the ambient environment surrounding a heterogeneous diffusion flame may be an inefficient technique for fire safety in systems without buoyant flows. Carbon dioxide substitution for nitrogen diluent leads to significant modifications of the sphero-symmetric burning behavior of isolated n-heptane droplets, partly through increased heat capacity within the gaseous diffusion flame, but mostly because of modifications in spectral radiative coupling in the gas phase. Effects of longer time scale phenomena such as sooting and slow gas-phase/droplet convection remain to be determined. Similar methodologies can be applied to evaluate the effects and efficacy of chemical inhibitors in the liquid and gas phases.
46 CFR 167.45-45 - Carbon dioxide fire extinguishing system requirements.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Carbon dioxide fire extinguishing system requirements. 167.45-45 Section 167.45-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-45 Carbon dioxide fire extinguishing system...
46 CFR 167.45-45 - Carbon dioxide fire extinguishing system requirements.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Carbon dioxide fire extinguishing system requirements. 167.45-45 Section 167.45-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-45 Carbon dioxide fire extinguishing system...
46 CFR 167.45-45 - Carbon dioxide fire extinguishing system requirements.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Carbon dioxide fire extinguishing system requirements. 167.45-45 Section 167.45-45 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) NAUTICAL SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-45 Carbon dioxide fire extinguishing system...
Mitigating operating room fires: development of a carbon dioxide fire prevention device.
Culp, William C; Kimbrough, Bradly A; Luna, Sarah; Maguddayao, Aris J
2014-04-01
Operating room fires are sentinel events that present a real danger to surgical patients and occur at least as frequently as wrong-sided surgery. For fire to occur, the 3 points of the fire triad must be present: an oxidizer, an ignition source, and fuel source. The electrosurgical unit (ESU) pencil triggers most operating room fires. Carbon dioxide (CO2) is a gas that prevents ignition and suppresses fire by displacing oxygen. We hypothesize that a device can be created to reduce operating room fires by generating a cone of CO2 around the ESU pencil tip. One such device was created by fabricating a divergent nozzle and connecting it to a CO2 source. This device was then placed over the ESU pencil, allowing the tip to be encased in a cone of CO2 gas. The device was then tested in 21%, 50%, and 100% oxygen environments. The ESU was activated at 50 W cut mode while placing the ESU pencil tip on a laparotomy sponge resting on an aluminum test plate for up to 30 seconds or until the sponge ignited. High-speed videography was used to identify time of ignition. Each test was performed in each oxygen environment 5 times with the device activated (CO2 flow 8 L/min) and with the device deactivated (no CO2 flow-control). In addition, 3-dimensional spatial mapping of CO2 concentrations was performed with a CO2 sampling device. The median ± SD [range] ignition time of the control group in 21% oxygen was 2.9 s ± 0.44 [2.3-3.0], in 50% oxygen 0.58 s ± 0.12 [0.47-0.73], and in 100% oxygen 0.48 s ± 0.50 [0.03-1.27]. Fires were ignited with each control trial (15/15); no fires ignited when the device was used (0/15, P < 0.0001). The CO2 concentration at the end of the ESU pencil tip was 95%, while the average CO2 concentration 1 to 1.4 cm away from the pencil tip on the bottom plane was 64%. In conclusion, an operating room fire prevention device can be created by using a divergent nozzle design through which CO2 passes, creating a cone of fire suppressant. This device as demonstrated in a flammability model effectively reduced the risk of fire. CO2 3-dimensional spatial mapping suggests effective fire reduction at least 1 cm away from the tip of the ESU pencil at 8 L/min CO2 flow. Future testing should determine optimum CO2 flow rates and ideal nozzle shapes. Use of this device may substantially reduce the risk of patient injury due to operating room fires.
46 CFR 35.40-10 - Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 1 2013-10-01 2013-10-01 false Steam, foam, carbon dioxide, or clean agent fire... TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-10 Steam, foam, carbon dioxide, or clean agent fire smothering apparatus—TB/ALL. Each steam, foam, carbon dioxide, or clean agent...
46 CFR 35.40-10 - Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 1 2014-10-01 2014-10-01 false Steam, foam, carbon dioxide, or clean agent fire... TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-10 Steam, foam, carbon dioxide, or clean agent fire smothering apparatus—TB/ALL. Each steam, foam, carbon dioxide, or clean agent...
Study of Hand-Held Fire Extinguishers Aboard Civil Aviation Aircraft.
1982-06-01
or combustion products of the polymers used in aircraft construction have been found to include carbon monoxide (CO), carbon dioxide (CO ), hydrogen...toxicity rating, and ease of cleanup. The extinguishing agents used in this country for hand portable fire extinguishers are Carbon Dioxide, water, Halon...point where combustion stops." " Carbon dioxide fire extinguishing systems are useful within the limits of this standard in extinguishing fires in
1983-12-01
carbon dioxide scrubbers , air conditioning, communications, lighting, and fire detecting and fire extinguishing systems. Medical support equipment was...10 14 Humidity...............................11 5. Hydrocarb on...........................11 B. Carbon Dioxide Scrubbers .....................11 C...and ancillary equipment included gas/vapor monitoring equipment, carbon dioxide scrubbers , air conditioning, communications, lighting, and fire
46 CFR 147.65 - Carbon dioxide and halon fire extinguishing systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 5 2011-10-01 2011-10-01 false Carbon dioxide and halon fire extinguishing systems. 147.65 Section 147.65 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES HAZARDOUS SHIPS' STORES Stowage and Other Special Requirements for Particular Materials § 147.65 Carbon dioxide and halon fire extinguishing...
46 CFR 147.65 - Carbon dioxide and halon fire extinguishing systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 5 2013-10-01 2013-10-01 false Carbon dioxide and halon fire extinguishing systems. 147.65 Section 147.65 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES HAZARDOUS SHIPS' STORES Stowage and Other Special Requirements for Particular Materials § 147.65 Carbon dioxide and halon fire extinguishing...
46 CFR 147.65 - Carbon dioxide and halon fire extinguishing systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 5 2012-10-01 2012-10-01 false Carbon dioxide and halon fire extinguishing systems. 147.65 Section 147.65 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DANGEROUS CARGOES HAZARDOUS SHIPS' STORES Stowage and Other Special Requirements for Particular Materials § 147.65 Carbon dioxide and halon fire extinguishing...
Selection and Use of Manganese Dioxide by Neanderthals
Heyes, Peter J.; Anastasakis, Konstantinos; de Jong, Wiebren; van Hoesel, Annelies; Roebroeks, Wil; Soressi, Marie
2016-01-01
Several Mousterian sites in France have yielded large numbers of small black blocs. The usual interpretation is that these ‘manganese oxides’ were collected for their colouring properties and used in body decoration, potentially for symbolic expression. Neanderthals habitually used fire and if they needed black material for decoration, soot and charcoal were readily available, whereas obtaining manganese oxides would have incurred considerably higher costs. Compositional analyses lead us to infer that late Neanderthals at Pech-de-l’Azé I were deliberately selecting manganese dioxide. Combustion experiments and thermo-gravimetric measurements demonstrate that manganese dioxide reduces wood’s auto-ignition temperature and substantially increases the rate of char combustion, leading us to conclude that the most beneficial use for manganese dioxide was in fire-making. With archaeological evidence for fire places and the conversion of the manganese dioxide to powder, we argue that Neanderthals at Pech-de-l’Azé I used manganese dioxide in fire-making and produced fire on demand. PMID:26922901
14 CFR 23.1197 - Fire extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing agents. 23.1197 Section... test except for built-in carbon dioxide fuselage compartment fire extinguishing systems for which— (1) Five pounds or less of carbon dioxide will be discharged, under established fire control procedures...
14 CFR 25.1197 - Fire extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 1 2010-01-01 2010-01-01 false Fire extinguishing agents. 25.1197 Section... test except for built-in carbon dioxide fuselage compartment fire extinguishing systems for which— (1) Five pounds or less of carbon dioxide will be discharged, under established fire control procedures...
NASA Technical Reports Server (NTRS)
Ruff, Gary A.
2004-01-01
This report is concerned with the following topics regarding fire suppression:What is the relative effectiveness of candidate suppressants to extinguish a representative fire in reduced gravity, including high-O2 mole fraction, low -pressure environments? What are the relative advantages and disadvantages of physically acting and chemically-acting agents in spacecraft fire suppression? What are the O2 mole fraction and absolute pressure below which a fire cannot exist? What effect does gas-phase radiation play in the overall fire and post-fire environments? Are the candidate suppressants effective to extinguish fires on practical solid fuels? What is required to suppress non-flaming fires (smoldering and deep seated fires) in reduced gravity? How can idealized space experiment results be applied to a practical fire scenario? What is the optimal agent deployment strategy for space fire suppression?
46 CFR 108.431 - Carbon dioxide systems: General.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide systems: General. 108.431 Section 108.431 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.431 Carbon dioxide systems: General. (a)...
46 CFR 108.431 - Carbon dioxide systems: General.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide systems: General. 108.431 Section 108.431 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.431 Carbon dioxide systems: General. (a)...
46 CFR 108.431 - Carbon dioxide systems: General.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide systems: General. 108.431 Section 108.431 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.431 Carbon dioxide systems: General. (a)...
46 CFR 108.431 - Carbon dioxide systems: General.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide systems: General. 108.431 Section 108.431 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.431 Carbon dioxide systems: General. (a)...
Methanol Droplet Extinction in Carbon-Dioxide-Enriched Environments in Microgravity
NASA Technical Reports Server (NTRS)
Hicks, Michael C.; Nayagam, Vedha; Williams, Forman A.
2010-01-01
Diffusive extinction of methanol droplets with initial diameters between 1.25 mm and 1.72 mm, burning in a quiescent microgravity environment at one atmosphere pressure, was obtained experimentally for varying levels of ambient carbon-dioxide concentrations with a fixed oxygen concentration of 21% and a balance of nitrogen. These experiments serve as precursors to those which are beginning to be performed on the International Space Station and are motivated by the need to understand the effectiveness of carbon-dioxide as a fire suppressant in low-gravity environments. In these experiments, the flame standoff distance, droplet diameter, and flame radiation are measured as functions of time. The results show that the droplet extinction diameter depends on both the initial droplet diameter and the ambient concentration of carbon dioxide. Increasing the initial droplet diameter leads to an increased extinction diameter, while increasing the carbon-dioxide concentration leads to a slight decrease in the extinction diameter. These results are interpreted using a critical Damk hler number for extinction as predicted by an earlier theory, which is extended here to be applicable in the presence of effects of heat conduction along the droplet support fibers and of the volume occupied by the support beads
46 CFR 131.815 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 131.815 Section 131.815 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
46 CFR 131.815 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 131.815 Section 131.815 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
46 CFR 131.815 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 131.815 Section 131.815 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.815 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
46 CFR 35.40-10 - Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Steam, foam, carbon dioxide, or clean agent fire smothering apparatus-TB/ALL. 35.40-10 Section 35.40-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-10 Steam, foam, carbon dioxide, or clean agent fire smothering apparatus—TB...
46 CFR 78.47-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 78.47-9 Section 78.47-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
46 CFR 78.47-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 78.47-9 Section 78.47-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
46 CFR 78.47-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 78.47-9 Section 78.47-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent fire...
Using unplanned fires to help suppressing future large fires in Mediterranean forests.
Regos, Adrián; Aquilué, Núria; Retana, Javier; De Cáceres, Miquel; Brotons, Lluís
2014-01-01
Despite the huge resources invested in fire suppression, the impact of wildfires has considerably increased across the Mediterranean region since the second half of the 20th century. Modulating fire suppression efforts in mild weather conditions is an appealing but hotly-debated strategy to use unplanned fires and associated fuel reduction to create opportunities for suppression of large fires in future adverse weather conditions. Using a spatially-explicit fire-succession model developed for Catalonia (Spain), we assessed this opportunistic policy by using two fire suppression strategies that reproduce how firefighters in extreme weather conditions exploit previous fire scars as firefighting opportunities. We designed scenarios by combining different levels of fire suppression efficiency and climatic severity for a 50-year period (2000-2050). An opportunistic fire suppression policy induced large-scale changes in fire regimes and decreased the area burnt under extreme climate conditions, but only accounted for up to 18-22% of the area to be burnt in reference scenarios. The area suppressed in adverse years tended to increase in scenarios with increasing amounts of area burnt during years dominated by mild weather. Climate change had counterintuitive effects on opportunistic fire suppression strategies. Climate warming increased the incidence of large fires under uncontrolled conditions but also indirectly increased opportunities for enhanced fire suppression. Therefore, to shift fire suppression opportunities from adverse to mild years, we would require a disproportionately large amount of area burnt in mild years. We conclude that the strategic planning of fire suppression resources has the potential to become an important cost-effective fuel-reduction strategy at large spatial scale. We do however suggest that this strategy should probably be accompanied by other fuel-reduction treatments applied at broad scales if large-scale changes in fire regimes are to be achieved, especially in the wider context of climate change.
30 CFR 75.1107 - Fire suppression devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...
30 CFR 75.1107 - Fire suppression devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...
30 CFR 75.1107 - Fire suppression devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...
30 CFR 75.1107 - Fire suppression devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...
30 CFR 75.1107 - Fire suppression devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Provisions] On and after March 30, 1971, fire-suppression devices meeting specifications prescribed by the... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire suppression devices. 75.1107 Section 75... HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and...
Using Unplanned Fires to Help Suppressing Future Large Fires in Mediterranean Forests
Regos, Adrián; Aquilué, Núria; Retana, Javier; De Cáceres, Miquel; Brotons, Lluís
2014-01-01
Despite the huge resources invested in fire suppression, the impact of wildfires has considerably increased across the Mediterranean region since the second half of the 20th century. Modulating fire suppression efforts in mild weather conditions is an appealing but hotly-debated strategy to use unplanned fires and associated fuel reduction to create opportunities for suppression of large fires in future adverse weather conditions. Using a spatially-explicit fire–succession model developed for Catalonia (Spain), we assessed this opportunistic policy by using two fire suppression strategies that reproduce how firefighters in extreme weather conditions exploit previous fire scars as firefighting opportunities. We designed scenarios by combining different levels of fire suppression efficiency and climatic severity for a 50-year period (2000–2050). An opportunistic fire suppression policy induced large-scale changes in fire regimes and decreased the area burnt under extreme climate conditions, but only accounted for up to 18–22% of the area to be burnt in reference scenarios. The area suppressed in adverse years tended to increase in scenarios with increasing amounts of area burnt during years dominated by mild weather. Climate change had counterintuitive effects on opportunistic fire suppression strategies. Climate warming increased the incidence of large fires under uncontrolled conditions but also indirectly increased opportunities for enhanced fire suppression. Therefore, to shift fire suppression opportunities from adverse to mild years, we would require a disproportionately large amount of area burnt in mild years. We conclude that the strategic planning of fire suppression resources has the potential to become an important cost-effective fuel-reduction strategy at large spatial scale. We do however suggest that this strategy should probably be accompanied by other fuel-reduction treatments applied at broad scales if large-scale changes in fire regimes are to be achieved, especially in the wider context of climate change. PMID:24727853
Development of the International Space Station Fine Water Mist Portable Fire Extinguisher
NASA Technical Reports Server (NTRS)
Rodriquez, Branelle; Young, GIna
2013-01-01
The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segments, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational and compatibility concerns with the emergency breathing equipment and the carbon dioxide extinguisher. ISS emergency response breathing equipment does not filter carbon dioxide; therefore, crew members are required to have an oxygen supply present during a fire event since the carbon dioxide PFE creates an unsafe breathing environment. The ISS program recommended a nontoxic fire extinguisher to mitigate this operational risk. The FWM PFE can extinguish a fire without creating a hazardous breathing environment for crewmembers. This paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, and discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.
Brotons, Lluís; Aquilué, Núria; de Cáceres, Miquel; Fortin, Marie-Josée; Fall, Andrew
2013-01-01
Available data show that future changes in global change drivers may lead to an increasing impact of fires on terrestrial ecosystems worldwide. Yet, fire regime changes in highly humanised fire-prone regions are difficult to predict because fire effects may be heavily mediated by human activities We investigated the role of fire suppression strategies in synergy with climate change on the resulting fire regimes in Catalonia (north-eastern Spain). We used a spatially-explicit fire-succession model at the landscape level to test whether the use of different firefighting opportunities related to observed reductions in fire spread rates and effective fire sizes, and hence changes in the fire regime. We calibrated this model with data from a period with weak firefighting and later assess the potential for suppression strategies to modify fire regimes expected under different levels of climate change. When comparing simulations with observed fire statistics from an eleven-year period with firefighting strategies in place, our results showed that, at least in two of the three sub-regions analysed, the observed fire regime could not be reproduced unless taking into account the effects of fire suppression. Fire regime descriptors were highly dependent on climate change scenarios, with a general trend, under baseline scenarios without fire suppression, to large-scale increases in area burnt. Fire suppression strategies had a strong capacity to compensate for climate change effects. However, strong active fire suppression was necessary to accomplish such compensation, while more opportunistic fire suppression strategies derived from recent fire history only had a variable, but generally weak, potential for compensation of enhanced fire impacts under climate change. The concept of fire regime in the Mediterranean is probably better interpreted as a highly dynamic process in which the main determinants of fire are rapidly modified by changes in landscape, climate and socioeconomic factors such as fire suppression strategies. PMID:23658726
Brotons, Lluís; Aquilué, Núria; de Cáceres, Miquel; Fortin, Marie-Josée; Fall, Andrew
2013-01-01
Available data show that future changes in global change drivers may lead to an increasing impact of fires on terrestrial ecosystems worldwide. Yet, fire regime changes in highly humanised fire-prone regions are difficult to predict because fire effects may be heavily mediated by human activities We investigated the role of fire suppression strategies in synergy with climate change on the resulting fire regimes in Catalonia (north-eastern Spain). We used a spatially-explicit fire-succession model at the landscape level to test whether the use of different firefighting opportunities related to observed reductions in fire spread rates and effective fire sizes, and hence changes in the fire regime. We calibrated this model with data from a period with weak firefighting and later assess the potential for suppression strategies to modify fire regimes expected under different levels of climate change. When comparing simulations with observed fire statistics from an eleven-year period with firefighting strategies in place, our results showed that, at least in two of the three sub-regions analysed, the observed fire regime could not be reproduced unless taking into account the effects of fire suppression. Fire regime descriptors were highly dependent on climate change scenarios, with a general trend, under baseline scenarios without fire suppression, to large-scale increases in area burnt. Fire suppression strategies had a strong capacity to compensate for climate change effects. However, strong active fire suppression was necessary to accomplish such compensation, while more opportunistic fire suppression strategies derived from recent fire history only had a variable, but generally weak, potential for compensation of enhanced fire impacts under climate change. The concept of fire regime in the Mediterranean is probably better interpreted as a highly dynamic process in which the main determinants of fire are rapidly modified by changes in landscape, climate and socioeconomic factors such as fire suppression strategies.
Estimating suppression expenditures for individual large wildland fires
Krista M. Gebert; David E. Calkin; Jonathan Yoder
2007-01-01
The extreme cost of fighting wildland fires has brought fire suppression expenditures to the forefront of budgetary and policy debate in the United States. Inasmuch as large fires are responsible for the bulk of fire suppression expenditures, understanding fire characteristics that influence expenditures is important for both strategic fire planning and onsite fire...
14 CFR 125.163 - Fire-extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fire-extinguishing agents. 125.163 Section... Requirements § 125.163 Fire-extinguishing agents. Only methyl bromide, carbon dioxide, or another agent that... some other person using satisfactory recharging equipment. If carbon dioxide is used, it must not be...
14 CFR 23.1197 - Fire extinguishing agents.
Code of Federal Regulations, 2012 CFR
2012-01-01
... materials in the area protected by the fire extinguishing system; and (2) Have thermal stability over the... exist in the extinguishing system. This must be shown by test except for built-in carbon dioxide fuselage compartment fire extinguishing systems for which— (1) Five pounds or less of carbon dioxide will...
Charles W. McHugh; Paul Gleason
2003-01-01
The purpose of this report is to document the suppression actions taken during the Hayman Fire. The long duration of suppression activities (June 8 through July 18), and multiple incident management teams assigned to the fire, makes this a challenging task. Original records and reports produced independently by the various teams assigned to different portions of the...
Charles W. McHugh; Mark A. Finney
2003-01-01
Effects of roads on fire behavior intensity and severity can be studied directly or indirectly. A direct study of road effects would include uses by fire suppression, burnout operations, and delay of fire progress at the roadside. Interpretations after the fire burns are easily confounded by the unknown nature of suppression activities and fire arrival time, and fire...
Allowing a wildfire to burn: estimating the effect on future fire suppression costs
Rachel M. Houtman; Claire A. Montgomery; Aaron R. Gagnon; David E. Calkin; Thomas G. Dietterich; Sean McGregor; Mark Crowley
2013-01-01
Where a legacy of aggressive wildland fire suppression has left forests in need of fuel reduction, allowing wildland fire to burn may provide fuel treatment benefits, thereby reducing suppression costs from subsequent fires. The least-cost-plus-net-value-change model of wildland fire economics includes benefits of wildfire in a framework for evaluating suppression...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Fire suppression devices; extinguishant supply systems. (a) Fire suppression systems using water or... equivalent protective devices and a rising stem or other visual indicator-type shutoff valve. (b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Fire suppression devices; extinguishant supply systems. (a) Fire suppression systems using water or... equivalent protective devices and a rising stem or other visual indicator-type shutoff valve. (b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Fire suppression devices; extinguishant supply systems. (a) Fire suppression systems using water or... equivalent protective devices and a rising stem or other visual indicator-type shutoff valve. (b) Water supplies for fire suppression devices installed on underground equipment may be maintained in mounted water...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tom Elicson; Bentley Harwood; Jim Bouchard
Over a 12 month period, a fire PRA was developed for a DOE facility using the NUREG/CR-6850 EPRI/NRC fire PRA methodology. The fire PRA modeling included calculation of fire severity factors (SFs) and fire non-suppression probabilities (PNS) for each safe shutdown (SSD) component considered in the fire PRA model. The SFs were developed by performing detailed fire modeling through a combination of CFAST fire zone model calculations and Latin Hypercube Sampling (LHS). Component damage times and automatic fire suppression system actuation times calculated in the CFAST LHS analyses were then input to a time-dependent model of fire non-suppression probability. Themore » fire non-suppression probability model is based on the modeling approach outlined in NUREG/CR-6850 and is supplemented with plant specific data. This paper presents the methodology used in the DOE facility fire PRA for modeling fire-induced SSD component failures and includes discussions of modeling techniques for: • Development of time-dependent fire heat release rate profiles (required as input to CFAST), • Calculation of fire severity factors based on CFAST detailed fire modeling, and • Calculation of fire non-suppression probabilities.« less
14 CFR 460.13 - Smoke detection and fire suppression.
Code of Federal Regulations, 2013 CFR
2013-01-01
... 14 Aeronautics and Space 4 2013-01-01 2013-01-01 false Smoke detection and fire suppression. 460... Crew § 460.13 Smoke detection and fire suppression. An operator or crew must have the ability to detect smoke and suppress a cabin fire to prevent incapacitation of the flight crew. ...
14 CFR 460.13 - Smoke detection and fire suppression.
Code of Federal Regulations, 2012 CFR
2012-01-01
... 14 Aeronautics and Space 4 2012-01-01 2012-01-01 false Smoke detection and fire suppression. 460... Crew § 460.13 Smoke detection and fire suppression. An operator or crew must have the ability to detect smoke and suppress a cabin fire to prevent incapacitation of the flight crew. ...
14 CFR 460.13 - Smoke detection and fire suppression.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 4 2010-01-01 2010-01-01 false Smoke detection and fire suppression. 460... Crew § 460.13 Smoke detection and fire suppression. An operator or crew must have the ability to detect smoke and suppress a cabin fire to prevent incapacitation of the flight crew. ...
14 CFR 460.13 - Smoke detection and fire suppression.
Code of Federal Regulations, 2014 CFR
2014-01-01
... 14 Aeronautics and Space 4 2014-01-01 2014-01-01 false Smoke detection and fire suppression. 460... Crew § 460.13 Smoke detection and fire suppression. An operator or crew must have the ability to detect smoke and suppress a cabin fire to prevent incapacitation of the flight crew. ...
14 CFR 460.13 - Smoke detection and fire suppression.
Code of Federal Regulations, 2011 CFR
2011-01-01
... 14 Aeronautics and Space 4 2011-01-01 2011-01-01 false Smoke detection and fire suppression. 460... Crew § 460.13 Smoke detection and fire suppression. An operator or crew must have the ability to detect smoke and suppress a cabin fire to prevent incapacitation of the flight crew. ...
Fire suppression effectiveness for simultaneous fires: an examination of fire histories
Larry F. Bednar; Romain Mees; David Strauss
1990-01-01
We examined fire and weather records for areas of the western United States for the period 1970-1984 to determine the effects of simultaneous wildfire occurrence on fire suppression efforts. Burning conditions were accounted for by use of short strings of fires which involved simultaneous suppression efforts. These strings were matched with closely preceding isolated...
Resource allocation for wildland fire suppression planning using a stochastic program
Alex Taylor Masarie
2011-01-01
Resource allocation for wildland fire suppression problems, referred to here as Fire-S problems, have been studied for over a century. Not only have the many variants of the base Fire-S problem made it such a durable one to study, but advances in suppression technology and our ever-expanding knowledge of and experience with wildland fire behavior have required almost...
NASA Technical Reports Server (NTRS)
Rodriquez, Branelle; Graf, John; Carlile, Christie; Young, GIna
2012-01-01
The National Aeronautics and Space Administration (NASA) is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station (ISS). The ISS presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the United States Orbital Segments, which include Columbus and Kibo pressurized elements. Currently, there are operational concerns with the emergency breathing equipment and the carbon dioxide extinguisher. The toxicity of the carbon dioxide requires the crew members to have an oxygen supply present during a fire event, therefore inherently creating an unsafe environment. The FWM PFE extinguishes a fire without creating a hazardous breathing environment for crew members. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE, identify unique microgravity design considerations for liquid and gas systems, as well as discuss the NASA ISS specific fire standards that were developed to establish an acceptable portable fire extinguisher s performance.
30 CFR 75.1107-13 - Approval of other fire suppression devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
... COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-13 Approval of... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Approval of other fire suppression devices. 75...
Geoffrey H. Donovan; Peter. Noordijk
2005-01-01
To determine the optimal suppression strategy for escaped wildfires, federal land managers are requiredto conduct a wildland fire situation analysis (WFSA). As part of the WFSA process, fire managers estimate final fire size and suppression costs. Estimates from 58 WFSAs conducted during the 2002 fire season are compared to actual outcomes. Results indicate that...
Preliminary Guidelines For Using Suppression Fires to Control Wildfires in the Southeast
Robert W. Cooper
1969-01-01
Suppression firing is defied as the application of fire to speed or strengthen control action on free-burning wildfires. The key to successful suppression firing is availability of personnel knowledgeable in specific application plus an adequate supply of manpower and equipment to contain the set fire. Preliminary guidelines for the use of this fire-control tool are...
Progress in Fire Detection and Suppression Technology for Future Space Missions
NASA Technical Reports Server (NTRS)
Friedman, Robert; Urban, David L.
2000-01-01
Fire intervention technology (detection and suppression) is a critical part of the strategy of spacecraft fire safety. This paper reviews the status, trends, and issues in fire intervention, particularly the technology applied to the protection of the International Space Station and future missions beyond Earth orbit. An important contribution to improvements in spacecraft fire safety is the understanding of the behavior of fires in the non-convective (microgravity) environment of Earth-orbiting and planetary-transit spacecraft. A key finding is the strong influence of ventilation flow on flame characteristics, flammability limits and flame suppression in microgravity. Knowledge of these flow effects will aid the development of effective processes for fire response and technology for fire suppression.
Francisco Rodríguez y Silva; Armando González-Cabán
2016-01-01
We propose an economic analysis using utility and productivity, and efficiency theories to provide fire managers a decision support tool to determine the most efficient fire management programs levels. By incorporating managersâ accumulated fire suppression experiences (capitalized experience) in the analysis we help fire managers...
Econometric analysis of fire suppression production functions for large wildland fires
Thomas P. Holmes; David E. Calkin
2013-01-01
In this paper, we use operational data collected for large wildland fires to estimate the parameters of economic production functions that relate the rate of fireline construction with the level of fire suppression inputs (handcrews, dozers, engines and helicopters). These parameter estimates are then used to evaluate whether the productivity of fire suppression inputs...
Quantifying the consequences of fire suppression in two California national parks
Carol Miller; Brett Davis
2009-01-01
Excluding fire can have untold ecological effects. Decades of fire suppression in national parks and other protected areas have altered natural fire regimes, vegetation, and wildlife habitat (Chang 1996; Keane et al. 2002). Management actions to suppress lightning-ignited wildfires removes one of the most important natural processes from fire-dependent ecosystems, and...
Developing Standards to Qualify a Fine Water Mist Fire Extinguisher for Human Spaceflight
NASA Technical Reports Server (NTRS)
Graf, John
2011-01-01
NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen systems increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide, so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. Compared to the carbon dioxide based Portable Fire Extinguisher, the flight qualification of Fine Water Mist systems requires special care. Qualification of the CO2 based Portable Fire Extinguisher began with the assumption that any fire on ISS would be extinguished if the air in the fire environment reached a critical concentration of CO2. Qualification of a CO2 based system requires the developers to make assertions and assumptions about vehicle geometry and the ability of the extinguisher to deliver CO2 in different geometric configurations, but the developers did not need to make assertions or assumptions about the size of the fire, the temperature, or the heat generation rate. Fine Water Mist systems extinguish a fire predominantly by removing heat -- so qualification standards must evaluate geometry, but also temperature, heat transfer, and heat generation rate. This paper outlines and describes the methods used to develop standards used to qualify Fine Water Mist systems for a human spaceflight environment.
Fire flood method for recovering petroleum from oil reservoirs of low permeability and temperature
Kamath, Krishna
1984-08-14
The present invention is directed to a method of enhanced oil recovery by fire flooding petroleum reservoirs characterized by a temperature of less than the critical temperature of carbon dioxide, a pore pressure greater than the saturated vapor pressure of carbon dioxide at said temperature (87.7.degree. F. at 1070 psia), and a permeability in the range of about 20 to 100 millidarcies. The in situ combustion of petroleum in the reservoir is provided by injecting into the reservoir a combustion supporting medium consisting essentially of oxygen, ozone, or a combination thereof. The heat of combustion and the products of this combustion which consist essentially of gaseous carbon dioxide and water vapor sufficiently decrease the viscosity of oil adjacent to fire front to form an oil bank which moves through the reservoir towards a recovery well ahead of the fire front. The gaseous carbon dioxide and the water vapor are driven into the reservoir ahead of the fire front by pressure at the injection well. As the gaseous carbon dioxide cools to less than about 88.degree. F. it is converted to liquid which is dissolved in the oil bank for further increasing the mobility thereof. By using essentially pure oxygen, ozone, or a combination thereof as the combustion supporting medium in these reservoirs the permeability requirements of the reservoirs are significantly decreased since the liquid carbon dioxide requires substantially less voidage volume than that required for gaseous combustion products.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-14
... Protection of Stratospheric Ozone: Listing of Substitutes for Ozone Depleting Substances--Fire Suppression... a companion proposed rule issuing listings for three fire suppressants under EPA's Significant New... companion proposed rule issuing listings for three fire suppressants under EPA's Significant New...
48 CFR 452.236-78 - Fire Suppression and Liability.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Fire Suppression and Liability. As prescribed in § 436.578, the following clause may be inserted in contracts awarded for Integrated Resource Service Contracts (IRSC) awarded for the Forest Service. Fire... 48 Federal Acquisition Regulations System 4 2014-10-01 2014-10-01 false Fire Suppression and...
46 CFR 108.444 - Lockout valves.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.444 Lockout valves. (a) A lockout valve must be provided on any carbon dioxide extinguishing system protecting a space over... complete isolation of the system from the protected space or spaces, making it impossible for carbon...
46 CFR 108.431 - Carbon dioxide systems: General.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Carbon dioxide systems: General. (a) Sections 108.431 through 108.457 apply to high pressure carbon dioxide fire extinguishing systems. (b) Low pressure systems, that is, those in which the carbon dioxide...
Alternative Fuels Data Center: Propane Related Links
Amerex Corporation's Vehicle Fire Suppression Systems are designed to warn the vehicle operator and suppress the fire, protecting both equipment and employees. Automatic systems suppress the fire in its
A synopsis of large or disastrous wildland fires
Robert E. Martin; David B. Sapsis
1995-01-01
Wildland fires have occurred for centuries in North America and other selected countries and can be segregated into three periods: prehistoric (presuppression) fires, suppression period fires, and fire management period fires. Prehistoric fires varied in size and damage but were probably viewed fatalistically. Suppression period fires were based on policy that excluded...
Matthew P. Thompson; Patrick Freeborn; Jon D. Rieck; Dave Calkin; Julie W. Gilbertson-Day; Mark A. Cochrane; Michael S. Hand
2016-01-01
We present a case study of the Las Conchas Fire (2011) to explore the role of previously burned areas (wildfires and prescribed fires) on suppression effectiveness and avoided exposure. Methodological innovations include characterisation of the joint dynamics of fire growth and suppression activities, development of a fire line effectiveness framework, and...
Yu Wei; Erin J. Belval; Matthew P. Thompson; Dave E. Calkin; Crystal S. Stonesifer
2016-01-01
Sharing fire engines and crews between fire suppression dispatch zones may help improve the utilisation of fire suppression resources. Using the Resource Ordering and Status System, the Predictive Servicesâ Fire Potential Outlooks and the Rocky Mountain Region Preparedness Levels from 2010 to 2013, we tested a simulation and optimisation procedure to transfer crews and...
Penman, T D; Collins, L; Price, O F; Bradstock, R A; Metcalf, S; Chong, D M O
2013-12-15
Large budgets are spent on both suppression and fuel treatments in order to reduce the risk of wildfires. There is little evidence regarding the relative contribution of fire weather, suppression and fuel treatments in determining the risk posed from wildfires. Here we undertake a simulation study in the Sydney Basin, Australia, to examine this question using a fire behaviour model (Phoenix Rapidfire). Results of the study indicate that fire behaviour is most strongly influenced by fire weather. Suppression has a greater influence on whether a fire reaches 5 ha in size compared to fuel treatments. In contrast, fuel treatments have a stronger effect on the fire size and maximum distance the fire travels. The study suggests that fire management agencies will receive additional benefits from fuel treatment if they are located in areas which suppression resources can respond rapidly and attempt to contain the fires. No combination of treatments contained all fires, and the proportion of uncontained fires increased under more severe fire weather when the greatest number of properties are lost. Our study highlights the importance of alternative management strategies to reduce the risk of property loss. Crown Copyright © 2013. Published by Elsevier Ltd. All rights reserved.
Retrospective fire modeling: Quantifying the impacts of fire suppression
Brett H. Davis; Carol Miller; Sean A. Parks
2010-01-01
Land management agencies need to understand and monitor the consequences of their fire suppression decisions. We developed a framework for retrospective fire behavior modeling and impact assessment to determine where ignitions would have spread had they not been suppressed and to assess the cumulative effects that would have resulted. This document is a general...
The Science of Prescribed Fire: to Enable a Different Kind of Control
Timothy E. Paysen; Marcia G. Narog; Jack D. Cohen
1998-01-01
A paradigm shift from fire suppression to fire suppression and prescription requires a shift in emphasis from simply controlling wildfire occurrence and spread to one that includes controlling characteristics of prescribed fire. Suppression focuses on preventing unwanted effects that might result from wildfire occurrence. Prescription promotes desired effects by...
Production and efficiency of large wildland fire suppression effort: A stochastic frontier analysis
Hari Katuwal; Dave Calkin; Michael S. Hand
2016-01-01
This study examines the production and efficiency of wildland fire suppression effort. We estimate the effectiveness of suppression resource inputs to produce controlled fire lines that contain large wildland fires using stochastic frontier analysis. Determinants of inefficiency are identified and the effects of these determinants on the daily production of...
The hidden consequences of fire suppression
Carol Miller
2012-01-01
Wilderness managers need a way to quantify and monitor the effects of suppressing lightning-caused wildfires, which can alter natural fire regimes, vegetation, and habitat. Using computerized models of fire spread, weather, and fuels, it is now possible to quantify many of the hidden consequences of fire suppression. Case study watersheds in Yosemite and Sequoia-Kings...
A mixed integer program to model spatial wildfire behavior and suppression placement decisions
Erin J. Belval; Yu Wei; Michael Bevers
2015-01-01
Wildfire suppression combines multiple objectives and dynamic fire behavior to form a complex problem for decision makers. This paper presents a mixed integer program designed to explore integrating spatial fire behavior and suppression placement decisions into a mathematical programming framework. Fire behavior and suppression placement decisions are modeled using...
14 CFR 121.265 - Fire-extinguishing agents.
Code of Federal Regulations, 2010 CFR
2010-01-01
... 14 Aeronautics and Space 3 2010-01-01 2010-01-01 false Fire-extinguishing agents. 121.265 Section...-extinguishing agents. Only methyl bromide, carbon dioxide, or another agent that has been shown to provide... satisfactory recharging equipment. If carbon dioxide is used, it must not be possible to discharge enough gas...
Foam as a Fire Suppressant: An Evaluation
Paul Schlobohm; Ron Rochna
1987-01-01
The ability of fire suppressant foams to improve ground-applied fire control efforts was evaluated. Foaming agents and foam-generating systems were examined. Performance evaluations were made for direct attack, indirect attack, and mop-up. Foam was determined to suppress and repel fire in situations where water did not. Cost comparisons of mop-up work showed straight...
30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Automatic fire sensors; actuation of fire...
30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...
30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...
30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.
Code of Federal Regulations, 2013 CFR
2013-07-01
... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...
30 CFR 75.1103-6 - Automatic fire sensors; actuation of fire suppression systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Automatic fire sensors; actuation of fire... Protection § 75.1103-6 Automatic fire sensors; actuation of fire suppression systems. Point-type heat sensors or automatic fire sensor and warning device systems may be used to actuate deluge-type water systems...
Code of Federal Regulations, 2012 CFR
2012-07-01
... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...
Code of Federal Regulations, 2014 CFR
2014-07-01
... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...
Code of Federal Regulations, 2013 CFR
2013-07-01
... the system at the base of the main sprinkler riser. l. Fire hydrants must be located within 250 feet... Suppression System(s) 1. General. This Appendix B contains information on the Fire-safety Detection and Suppression System(s) tested by NARA through independent live fire testing that are certified to meet the...
46 CFR 167.45-45 - Carbon dioxide fire-extinguishing system requirements.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-45... school ship propelled by internal combustion engines, the quantity of carbon dioxide required may be... arrangement of the piping shall be such as to give a general and fairly uniform distribution over the entire...
46 CFR 167.45-45 - Carbon dioxide fire-extinguishing system requirements.
Code of Federal Regulations, 2011 CFR
2011-10-01
... SCHOOLS PUBLIC NAUTICAL SCHOOL SHIPS Special Firefighting and Fire Prevention Requirements § 167.45-45... school ship propelled by internal combustion engines, the quantity of carbon dioxide required may be... arrangement of the piping shall be such as to give a general and fairly uniform distribution over the entire...
46 CFR 35.40-7 - Carbon dioxide alarm-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 1 2010-10-01 2010-10-01 false Carbon dioxide alarm-T/ALL. 35.40-7 Section 35.40-7... Requirements-TB/ALL. § 35.40-7 Carbon dioxide alarm—T/ALL. Adjacent to all carbon dioxide fire extinguishing... AT ONCE. CARBON DIOXIDE BEING RELEASED.” ...
Space Experiment Concepts: Cup-Burner Flame Extinguishment
NASA Technical Reports Server (NTRS)
Takahashi, Fumiaki
2004-01-01
Space Fire Suppression Processes & Technology. Space experiment concepts of cup-burner flame extinguishment have been conceived to address to the key issues (i.e., organizing questions) in space fire suppression. Cup-burner flame extinguishment experiment can reveal physical and chemical suppression processes and provide agent effectiveness data useful for technology development of space fire suppression systems in various reduced-gravity platforms.
Prediction errors in wildland fire situation analyses.
Geoffrey H. Donovan; Peter Noordijk
2005-01-01
Wildfires consume budgets and put the heat on fire managers to justify and control suppression costs. To determine the appropriate suppression strategy, land managers must conduct a wildland fire situation analysis (WFSA) when:A wildland fire is expected to or does escape initial attack,A wildland fire managed for resource benefits...
Alternative approach for fire suppression of class A, B and C fires in gloveboxes
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosenberger, Mark S; Tsiagkouris, James A
2011-02-10
Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, ismore » capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.« less
33 CFR 149.416 - What are the requirements for a dry chemical fire suppression system?
Code of Federal Regulations, 2010 CFR
2010-07-01
... the requirements for a dry chemical fire suppression system? Each natural gas deepwater port must be... dry chemical fire suppression system? 149.416 Section 149.416 Navigation and Navigable Waters COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) DEEPWATER PORTS DEEPWATER PORTS: DESIGN, CONSTRUCTION...
46 CFR 196.37-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...
46 CFR 97.37-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping... Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...
46 CFR 196.37-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide alarm. 196.37-9 Section 196.37-9 Shipping... Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM SOUNDS—VACATE AT ONCE. CARBON DIOXIDE BEING...
Overview of ISS U.S. Fire Detection and Suppression System
NASA Technical Reports Server (NTRS)
Whitaker, Alana
2003-01-01
This paper presents a general overview of the International Space Station's Fire Detection and Suppression System. The topics include: 1) Introduction to Fire Detection and Suppression (FDS); 2) Description of (FDS) Subsystems; 3) FDS System Component Location and Status; 4) FDS System Capabilities; 5) FDS Automatic and Manual Response; 6) Post Fire Atmosphere Restoration and Air Quality Assessment; and 7) FDS Research Needs. This paper is in viewgraph form.
Space station internal environmental and safety concerns
NASA Technical Reports Server (NTRS)
Cole, Matthew B.
1987-01-01
Space station environmental and safety concerns, especially those involving fires, are discussed. Several types of space station modules and the particular hazards associated with each are briefly surveyed. A brief history of fire detection and suppression aboard spacecraft is given. Microgravity fire behavior, spacecraft fire detector systems, space station fire suppression equipment and procedures, and fire safety in hyperbaric chambers are discussed.
Effect of suppression strategies on federal wildland fire expenditures
Krista M. Gebert; Anne E. Black
2012-01-01
Policymakers and decisionmakers alike have suggested that the use of less aggressive suppression strategies for wildland fires might help stem the tide of rising emergency wildland fire expenditures. However, the interplay of wildland fire management decisions and expenditures is not well understood. In this study, we assess the effect of different fire management...
Short-term responses of birds to prescribed fire in fire-suppressed forests of California
Bagne Karen; Kathryn Purcell
2011-01-01
Prescribed fire is one tool for restoring fire-suppressed forests, but application of fire during spring coincides with breeding and arrival of migrant birds. We examined effects of low-severity prescribed fires on counts of birds in a managed forest in the Sierra Nevada of California immediately, 1 year, and 3â6 years after fire was applied in spring. Of 26 species...
46 CFR 193.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Carbon dioxide storage. 193.15-20 Section 193.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-20 Carbon dioxide storage. (a...
46 CFR 193.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Carbon dioxide storage. 193.15-20 Section 193.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-20 Carbon dioxide storage. (a...
Bird assemblage response to restoration of fire-suppressed longleaf pine sandhills.
Steen, David A; Conner, L M; Smith, Lora L; Provencher, Louis; Hiers, J Kevin; Pokswinski, Scott; Helms, Brian S; Guyer, Craig
2013-01-01
The ecological restoration of fire-suppressed habitats may require a multifaceted approach. Removal of hardwood trees together with reintroduction of fire has been suggested as a method of restoring fire-suppressed longleaf pine (Pinus palustris) forests; however, this strategy, although widespread, has not been evaluated on large spatial and temporal scales. We used a landscape-scale experimental design to examine how bird assemblages in fire-suppressed longleaf pine sandhills responded to fire alone or fire following mechanical removal or herbicide application to reduce hardwood levels. Individual treatments were compared to fire-suppressed controls and reference sites. After initial treatment, all sites were managed with prescribed fire, on an approximately two- to three-year interval, for over a decade. Nonmetric multidimensional scaling ordinations suggested that avian assemblages on sites that experienced any form of hardwood removal differed from assemblages on both fire-suppressed sites and reference sites 3-4 years after treatment (i.e., early posttreatment). After >10 years of prescribed burning on all sites (i.e., late posttreatment), only assemblages at sites treated with herbicide were indistinguishable from assemblages at reference sites. By the end of the study, individual species that were once indicators of reference sites no longer contributed to making reference sites unique. Occupancy modeling of these indicator species also demonstrated increasing similarity across treatments over time. Overall, although we documented long-term and variable assemblage-level change, our results indicate occupancy for birds considered longleaf pine specialists was similar at treatment and reference sites after over a decade of prescribed burning, regardless of initial method of hardwood removal. In other words, based on the response of species highly associated with the habitat, we found no justification for the added cost and effort of fire surrogates; fire alone was sufficient to restore these species.
Effects of fire suppression under a changing climate in Pacific Northwest mixed-pine forests
NASA Astrophysics Data System (ADS)
Hanan, E. J.; Tague, C.; Bart, R. R.; Kennedy, M. C.; Abatzoglou, J. T.; Kolden, C.; Adam, J. C.
2017-12-01
The frequency of large and severe wildfires has increased over recent decades in many regions across the Western U.S., including the Pacific and Inland Northwest. This increase is likely driven in large part by wildfire suppression, which has promoted fuel accumulation in western landscapes. Recent studies also suggest that anthropogenic climate change intensifies wildfire activity by increasing fuel aridity. However, the contribution of these drivers to observed changes in fire regime is not well quantified at regional scales. Understanding the relative influence of climate and fire suppression is crucial for both projecting the effects of climate change on future fire spread, and for developing site-specific fuel management strategies under a new climate paradigm. To quantify the extent to which fire suppression and climate change have contributed to increases in wildfire activity in the Pacific Northwest, we conduct a modeling experiment using the ecohydrologic model RHESSys and the coupled stochastic fire spread model WMFire. Specifically, we use historical climate inputs from GCMs, combined with fire suppression scenarios to gauge the extent to which these drivers promote the spread of severe wildfires in Johnson Creek, a large (565-km2) mixed-pine dominated subcatchment of the Southfork Salmon River; part of the larger Columbia River Basin. We run 500 model iterations for suppressed, intermediate, and unsuppressed fire management scenarios, both with and without climate change in a factorial design, focusing on fire spread surrounding two extreme fire years in Johnson Creek (1998 and 2007). After deriving fire spread "fingerprints" for each combination of possible drivers, we evaluate the extent to which these fingerprints match observations in the fire record. We expect that climate change plays a role in the spread of large and severe wildfires in Johnson Creek, but the magnitude of this effect is mediated by prior suppression. Preliminary results suggest that management strategies aimed at reducing the extent of contiguous even-aged fuels may help curtail climate-driven increases in wildfire severity in Pacific Northwest watersheds.
NASA Technical Reports Server (NTRS)
Nichols, J. D.; Britten, R. A.; Parks, G. S.; Voss, J. M.
1990-01-01
NASA's JPL has completed a feasibility study using infrared technologies for wildland fire suppression and management. The study surveyed user needs, examined available technologies, matched the user needs with technologies, and defined an integrated infrared wildland fire mapping concept system configuration. System component trade-offs were presented for evaluation in the concept system configuration. The economic benefits of using infrared technologies in fire suppression and management were examined. Follow-on concept system configuration development and implementation were proposed.
Production and efficiency of large wildland fire suppression effort: A stochastic frontier analysis.
Katuwal, Hari; Calkin, David E; Hand, Michael S
2016-01-15
This study examines the production and efficiency of wildland fire suppression effort. We estimate the effectiveness of suppression resource inputs to produce controlled fire lines that contain large wildland fires using stochastic frontier analysis. Determinants of inefficiency are identified and the effects of these determinants on the daily production of controlled fire line are examined. Results indicate that the use of bulldozers and fire engines increase the production of controlled fire line, while firefighter crews do not tend to contribute to controlled fire line production. Production of controlled fire line is more efficient if it occurs along natural or built breaks, such as rivers and roads, and within areas previously burned by wildfires. However, results also indicate that productivity and efficiency of the controlled fire line are sensitive to weather, landscape and fire characteristics. Copyright © 2015 Elsevier Ltd. All rights reserved.
Fire retardant foams developed to suppress fuel fires
NASA Technical Reports Server (NTRS)
Fish, R.; Gilwee, W. J.; Parker, J. A.; Riccitiello, S. R.
1968-01-01
Heat insulating polyurethane foam retards and suppresses fuel fires. Uniformly dispersed in the foam is a halogenated polymer capable of splitting off hydrogen halide upon heating and charring of the polyurethane.
Wildfire and drought dynamics destabilize carbon stores of fire-suppressed forests.
Earles, J Mason; North, Malcolm P; Hurteau, Matthew D
2014-06-01
Widespread fire suppression and thinning have altered the structure and composition of many forests in the western United States, making them more susceptible to the synergy of large-scale drought and fire events. We examine how these changes affect carbon storage and stability compared to historic fire-adapted conditions. We modeled carbon dynamics under possible drought and fire conditions over a 300-year simulation period in two mixed-conifer conditions common in the western United States: (1) pine-dominated with an active fire regime and (2) fir-dominated, fire suppressed forests. Fir-dominated stands, with higher live- and dead-wood density, had much lower carbon stability as drought and fire frequency increased compared to pine-dominated forest. Carbon instability resulted from species (i.e., fir's greater susceptibility to drought and fire) and stand (i.e., high density of smaller trees) conditions that develop in the absence of active management. Our modeling suggests restoring historic species composition and active fire regimes can significantly increase carbon stability in fire-suppressed, mixed-conifer forests. Long-term management of forest carbon should consider the relative resilience of stand structure and composition to possible increases in disturbance frequency and intensity under changing climate.
46 CFR 76.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Carbon dioxide storage. 76.15-20 Section 76.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-20 Carbon dioxide storage. (a) Except as...
46 CFR 95.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Carbon dioxide storage. 95.15-20 Section 95.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-20 Carbon dioxide storage. (a...
46 CFR 76.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Carbon dioxide storage. 76.15-20 Section 76.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-20 Carbon dioxide storage. (a) Except as...
46 CFR 95.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide storage. 95.15-20 Section 95.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-20 Carbon dioxide storage. (a...
46 CFR 76.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Carbon dioxide storage. 76.15-20 Section 76.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-20 Carbon dioxide storage. (a) Except as...
46 CFR 95.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide storage. 95.15-20 Section 95.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-20 Carbon dioxide storage. (a...
46 CFR 76.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Carbon dioxide storage. 76.15-20 Section 76.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-20 Carbon dioxide storage. (a) Except as...
Fire Effects Planning Framework: A user's guide
A. Black; T. Opperman
2005-01-01
Each decision to suppress fire reinforces a feedback cycle in which fuels continue to accumulate, risk escalates, and the tendency to suppress fires grows (Miller and others, 2003). Existing decision-support tools focus primarily on the negative consequences of fire. This guide outlines a framework managers can use to (1) identify key areas of fire risk and (2)...
Deploying wildland fire suppression resources with a scenario-based standard response model.
Robert G. Haight; Jeremy S. Fried
2007-01-01
Wildland fire managers deploy suppression resources to bases and dispatch them to fires to maximize the percentage of fires that are successfully contained before unacceptable costs and losses occur. Deployment is made with budget constraints and uncertainty about the daily number, location, and intensity of fires, all of which affect initial-attack success. To address...
Deploying wildland fire suppression resources with a scenario-based standard response model
Robert G. Haight; Jeremy S. Fried
2007-01-01
Wildland fire managers deploy suppression resources to bases and dispatch them to fires to maximize the percentage of fires that are successfully contained before unacceptable costs and losses occur. Deployment is made with budget constraints and uncertainty about the daily number, location, and intensity of fires, all of which affect initial-attack success. To address...
NASA Astrophysics Data System (ADS)
Kennedy, R. S.
2010-12-01
Forests of the mountainous landscapes of the maritime Pacific Northwestern USA may have high carbon sequestration potential via their high productivity and moderate to infrequent fire regimes. With climate change, there may be shifts in incidence and severity of fire, especially in the drier areas of the region, via changes to forest productivity and hydrology, and consequent effects to C sequestration and forest structure. To explore this issue, I assessed potential effects of fire management (little fire suppression/wildland fire management/highly effective fire suppression) under two climate change scenarios on future C sequestration dynamics (amounts and spatial pattern) in Olympic National Park, WA, over a 500-year simulation period. I used the simulation platform FireBGCv2, which contains a mechanistic, individual tree succession model, a spatially explicit climate-based biophysical model that uses daily weather data, and a spatially explicit fire model incorporating ignition, spread, and effects on ecosystem components. C sequestration patterns varied over time and spatial and temporal patterns differed somewhat depending on the climate change scenario applied and the fire management methods employed. Under the more extreme climate change scenario with little fire suppression, fires were most frequent and severe and C sequestration decreased. General trends were similar under the more moderate climate change scenario, as compared to current climate, but spatial patterns differed. Both climate change scenarios under highly effective fire suppression showed about 50% of starting total C after the initial transition phase, whereas with 10% fire suppression both scenarios exhibited about 10% of starting amounts. Areas of the landscape that served as refugia for older forest under increasing frequency of high severity fire were also hotspots for C sequestration in a landscape experiencing increasing frequency of disturbance with climate change.
Spatially explicit forecasts of large wildland fire probability and suppression costs for California
Haiganoush Preisler; Anthony L. Westerling; Krista M. Gebert; Francisco Munoz-Arriola; Thomas P. Holmes
2011-01-01
In the last decade, increases in fire activity and suppression expenditures have caused budgetary problems for federal land management agencies. Spatial forecasts of upcoming fire activity and costs have the potential to help reduce expenditures, and increase the efficiency of suppression efforts, by enabling them to focus resources where they have the greatest effect...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...
30 CFR 75.1107-8 - Fire suppression devices; extinguishant supply systems.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-8... liquid chemical to protect attended equipment shall: (1) Be maintained at a pressure consistent with the...
46 CFR 122.612 - Fire protection equipment.
Code of Federal Regulations, 2010 CFR
2010-10-01
... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...
46 CFR 122.612 - Fire protection equipment.
Code of Federal Regulations, 2013 CFR
2013-10-01
... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...
46 CFR 122.612 - Fire protection equipment.
Code of Federal Regulations, 2012 CFR
2012-10-01
... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...
46 CFR 122.612 - Fire protection equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...
46 CFR 122.612 - Fire protection equipment.
Code of Federal Regulations, 2014 CFR
2014-10-01
... marked in clearly legible letters “FIRE ALARM”. (f) An alarm for an automatic sprinkler system must be... fixed gas fire extinguishing system must be located in a conspicuous place at or near each pull box and... “carbon dioxide.” (c) Each distribution line valve of a fixed gas fire extinguishing system and the fire...
Definition of experiments to investigate fire suppressants in microgravity
NASA Technical Reports Server (NTRS)
Reuther, James J.
1990-01-01
Defined and justified here are the conceptual design and operation of a critical set of experiments expected to yield information on suppressants and on suppressant delivery systems under realistic spacecraft-fire conditions (smoldering). Specific experiment parameters are provided on the solid fuel (carbon), oxidants (habitable spacecraft atmospheres), fuel/oxidant supply, mixing mode, and rate (quiescent and finite; ventilated and replenishable), ignition mode, event, and reignition tendency, fire-zone size, fire conditions, lifetime, and consequences (toxicity), suppressants (CO2, H2O, N2) and suppressant delivery systems, and diagnostics. Candidate suppressants were identified after an analysis of how reduced gravity alters combustion, and how these alterations may influence the modes, mechanisms, and capacities of terrestrial agents to suppress unwanted combustion, or fire. Preferred spacecraft suppression concepts included the local, near-quiescent application of a gas, vapor, or mist that has thermophysical fire-suppression activity and is chemically inert under terrestrial (normal gravity) combustion conditions. The scale, number, and duration (about 1 hour) of the proposed low-gravity experiments were estimated using data not only on the limitations imposed by spacecraft-carrier (Shuttle or Space Station Freedom) accommodations, but also data on the details and experience of standardized smolder-suppression experiments at normal gravity. Deliberately incorporated into the conceptual design was sufficient interchangeability for the prototype experimental package to fly either on Shuttle now or Freedom later. This flexibility is provided by the design concept of up to 25 modular fuel canisters within a containment vessel, which permits both integration into existing low-gravity in-space combustion experiments and simultaneous testing of separate experiments to conserve utilities and time.
Wildfire Policy in Mediterranean France: How Far is it Efficient and Sustainable?
Curt, Thomas; Frejaville, Thibaut
2018-03-01
A new fire policy reinforcing aggressive fire suppression was established in Mediterranean France in response to the devastating wildfires of the 1990s, but to what extent this has changed fire activity yet remains poorly understood. For this purpose, we compared the number and location of ignitions and of burned areas between two 20-year periods (1975-1994 vs. 1995-2014), in parallel to the changes in fuel covering, human activity promoting ignitions, and fire weather. The number of fires decreased almost continuously since 1975, but sharply after 1994, suggesting an effect of better fire prevention due to the new policy. But the major change in fire activity is a considerable reduction in fire size and burned areas after 1994, especially during summer and in the most fire-prone places, in response to massive efforts put into fire suppression. These reductions have occurred while the covering by fuel biomass, the human pressure on ignition, and the fire weather index increased, thus making the study area more hazardous. Our results suggest that a strategy of aggressive fire suppression has great potential for counterbalancing the effects of climate changes and human activities and for controlling fire activity in the short term. However, we discuss whether such a suppression-oriented approach is sustainable in the context of global changes, which cast new fire challenges as demonstrated by the devastative fires of 2003 and 2016. We advocate for a more comprehensive fire policy to come. © 2017 Society for Risk Analysis.
Economic cost of initial attack and large-fire suppression
Armando González-Cabán
1983-01-01
A procedure has been developed for estimating the economic cost of initial attack and large-fire suppression. The procedure uses a per-unit approach to estimate total attack and suppression costs on an input-by-input basis. Fire management inputs (FMIs) are the production units used. All direct and indirect costs are charged to the FMIs. With the unit approach, all...
Forest service large fire area burned and suppression expenditure trends, 1970-2002.
David E. Calkin; Krista M. Gebert; J. Greg Jones; Ronald P. Neilson
2005-01-01
Extreme fire seasons in recent years and associated high suppression expenditures have brought about a chorus of calls for reform of federal firefighting structure and policy. Given the political nature of the topic, a critical review of past trends in area burned, size of fires, and suppression expenditures is warranted. We examined data relating to emergency wildland...
NASA Technical Reports Server (NTRS)
Takahashi, Fumiaki; Linteris, Gregory T.; Katta, Viswanath R.
2003-01-01
Longer duration missions to the moon, to Mars, and on the International Space Station (ISS) increase the likelihood of accidental fires. NASA's fire safety program for human-crewed space flight is based largely on removing ignition sources and controlling the flammability of the material on-board. There is ongoing research to improve the flammability characterization of materials in low gravity; however, very little research has been conducted on fire suppression in the low-gravity environment. Although the existing suppression systems aboard the Space Shuttle (halon 1301, CF3Br) and the ISS (CO2 or water-based form) may continue to be used, alternative effective agents or techniques are desirable for long-duration missions. The goal of the present investigation is to: (1) understand the physical and chemical processes of fire suppression in various gravity and O2 levels simulating spacecraft, Mars, and moon missions; (2) provide rigorous testing of analytical models, which include detailed combustion-suppression chemistry and radiation sub-models, so that the model can be used to interpret (and predict) the suppression behavior in low gravity; and (3) provide basic research results useful for advances in space fire safety technology, including new fire-extinguishing agents and approaches.
46 CFR 193.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Carbon dioxide storage. 193.15-20 Section 193.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems, Details § 193.15-20 Carbon dioxide storage. (a) Except as provided in...
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2011 CFR
2011-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
30 CFR 75.1107-3 - Fire suppression devices; approved components; installation requirements.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Protection Fire Suppression Devices and Fire-Resistant Hydraulic Fluids on Underground Equipment § 75.1107-3... agency approved by the Secretary. (b) Where used, pressure vessels shall conform with the requirements of...
Numerical modeling of water spray suppression of conveyor belt fires in a large-scale tunnel.
Yuan, Liming; Smith, Alex C
2015-05-01
Conveyor belt fires in an underground mine pose a serious life threat to miners. Water sprinkler systems are usually used to extinguish underground conveyor belt fires, but because of the complex interaction between conveyor belt fires and mine ventilation airflow, more effective engineering designs are needed for the installation of water sprinkler systems. A computational fluid dynamics (CFD) model was developed to simulate the interaction between the ventilation airflow, the belt flame spread, and the water spray system in a mine entry. The CFD model was calibrated using test results from a large-scale conveyor belt fire suppression experiment. Simulations were conducted using the calibrated CFD model to investigate the effects of sprinkler location, water flow rate, and sprinkler activation temperature on the suppression of conveyor belt fires. The sprinkler location and the activation temperature were found to have a major effect on the suppression of the belt fire, while the water flow rate had a minor effect.
Numerical modeling of water spray suppression of conveyor belt fires in a large-scale tunnel
Yuan, Liming; Smith, Alex C.
2015-01-01
Conveyor belt fires in an underground mine pose a serious life threat to miners. Water sprinkler systems are usually used to extinguish underground conveyor belt fires, but because of the complex interaction between conveyor belt fires and mine ventilation airflow, more effective engineering designs are needed for the installation of water sprinkler systems. A computational fluid dynamics (CFD) model was developed to simulate the interaction between the ventilation airflow, the belt flame spread, and the water spray system in a mine entry. The CFD model was calibrated using test results from a large-scale conveyor belt fire suppression experiment. Simulations were conducted using the calibrated CFD model to investigate the effects of sprinkler location, water flow rate, and sprinkler activation temperature on the suppression of conveyor belt fires. The sprinkler location and the activation temperature were found to have a major effect on the suppression of the belt fire, while the water flow rate had a minor effect. PMID:26190905
Highly Effective, Low Toxicity, Low Environmental Impact Total Flooding Fire Suppressants
NASA Technical Reports Server (NTRS)
Glass, S. M.; Dhooge, P. M.; Nimitz, J. S.
2001-01-01
Halon 1301 (CF3Br) has been used for decades as the primary fire suppression agent for areas where powder agents cannot be used because of concerns for sensitive equipment. Halon 1301 is an excellent extinguishing agent, effective at about 3% in air and quite non-toxic. It has an effective exposure limit much greater than its extinguishing concentration, so it can be used in normally occupied areas. The ability of a chemical to destroy stratospheric ozone is its ozone-depletion potential (ODP). ODP is the amount of ozone destroyed per pound of a chemical, relative to the standard CFC-11 with an ODP = 1.0. Because halons have been implicated in stratospheric ozone depletion, their production was stopped at the end of 1995 under the provisions of the Montreal Protocol plus later amendments. In the US, the Clean Air Act Amendments of 1990, Presidential directives, and DoD Directive 6050.9 implemented this phaseout. These regulations and penalties have provided strong incentives for US businesses to decrease CFC use. The Omnibus Budget Reconciliation Act of 1989 mandates high Federal taxes on CFCs and halons, designed to price them out of the market. The taxes also capture for the government the windfall profits that would otherwise go to producers as scarcity drives up prices. Several replacements have been developed for Halon 1301. One is carbon dioxide, which has been used as a firefighting agent for many years. However, a high concentration of carbon dioxide is necessary to inert fuels. The effective concentration for inerting with carbon dioxide is approximately 29%, which is above the concentration lethal to humans. HFC-227ea is being used extensively to replace Halon 1301 systems in nominally occupied areas and some normally unoccupied areas. However, since the effective concentration of HFC-227ea is about three to four times that of Halon 1301 the extinguishing systems have to be larger and new extinguishing systems have to be installed. HFC-125 is also being sold as an extinguishing agent (Nimitz). It has problems similar to HFC-227ea, with a greater concentration needed for effectiveness and the need to use a larger system. This is a particularly onerous penalty in aircraft and spacecraft, where weight and space are extremely important, and substitution is often impossible in existing aircraft due to space limitations.
Factors influencing large wildland fire suppression expenditures
Jingjing Liang; Dave E. Calkin; Krista M. Gebert; Tyron J. Venn; Robin P. Silverstein
2008-01-01
There is an urgent and immediate need to address the excessive cost of large fires. Here, we studied large wildland fire suppression expenditures by the US Department of Agriculture Forest Service. Among 16 potential nonmanagerial factors, which represented fire size and shape, private properties, public land attributes, forest and fuel conditions, and geographic...
Allen, J.C.; Krieger, S.M.; Walters, J.R.; Collazo, J.A.
2006-01-01
We determined the effects of fire history and a riparian-upland gradient on the breeding bird community at Fort Bragg Military Installation in North Carolina, one of the largest remnant areas of the endangered longleaf pine (Pinus palustris) ecosystem. Study sites were classified into two treatments: fire-intense (areas experiencing growing-season burns) and fire-suppressed (areas lacking fires). Within each treatment, bird and vegetation data were recorded at point-count stations positioned at three distances from streamhead pocosins to characterize the riparian-upland habitat gradient: 0, 75, and ≥150 m. Total bird abundance and species richness varied significantly along the riparian-upland gradient, with pocosins contributing greatly to avian biodiversity. Our data revealed strong effects of fire history and riparian-upland gradient on bird species, which we described in terms of breeding-bird assemblages. Members of the open longleaf assemblage (e.g., Red- cockaded Woodpecker [Picoides borealis], Bachman's Sparrow [Aimophila aestivalis]) were most common in fire-intense areas and at upland locations. Members of the fire-suppressed assemblage (e.g., Wood Thrush [Hylocichla mustelina], Ovenbird [Seiurus aurocapilla]) were confined to pocosins in fire-intense areas, but became more abundant in fire-suppressed areas. Members of the pocosin assemblage (e.g., Eastern Towhee [Pipilo erythropthalamus], Common Yellowthroat [Geothlypis trichas]) were largely confined to pocosins and, in some cases, were most abundant in fire-intense pocosins. Fire suppression increased structural diversity of vegetation and promoted one breeding-bird assemblage (fire-suppressed), but at the expense of two others (open longleaf, pocosin). Continued management of Fort Bragg to promote longleaf pine restoration is essential for supporting conservation of the open-longleaf bird assemblage; in addition, it will benefit the pocosin assemblage.
Collins, Ross D; de Neufville, Richard; Claro, João; Oliveira, Tiago; Pacheco, Abílio P
2013-11-30
Forest fires are a serious management challenge in many regions, complicating the appropriate allocation to suppression and prevention efforts. Using a System Dynamics (SD) model, this paper explores how interactions between physical and political systems in forest fire management impact the effectiveness of different allocations. A core issue is that apparently sound management can have unintended consequences. An instinctive management response to periods of worsening fire severity is to increase fire suppression capacity, an approach with immediate appeal as it directly treats the symptom of devastating fires and appeases the public. However, the SD analysis indicates that a policy emphasizing suppression can degrade the long-run effectiveness of forest fire management. By crowding out efforts to preventative fuel removal, it exacerbates fuel loads and leads to greater fires, which further balloon suppression budgets. The business management literature refers to this problem as the firefighting trap, wherein focus on fixing problems diverts attention from preventing them, and thus leads to inferior outcomes. The paper illustrates these phenomena through a case study of Portugal, showing that a balanced approach to suppression and prevention efforts can mitigate the self-reinforcing consequences of this trap, and better manage long-term fire damages. These insights can help policymakers and fire managers better appreciate the interconnected systems in which their authorities reside and the dynamics that may undermine seemingly rational management decisions. Copyright © 2013 Elsevier Ltd. All rights reserved.
46 CFR 194.20-7 - Fire protection.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Fire protection. 194.20-7 Section 194.20-7 Shipping... Fire protection. (a) Each chemical storeroom shall be protected by a fixed automatic carbon dioxide... fire extinguishers are required in accordance with Table 193.50-10(a) of this subchapter. ...
Janie Canton-Tompson; Krista M. Gebert; Brooke Thompson; Greg Jones; David Calkin; Geoff Donovan
2008-01-01
Large wildland fires are complex, costly events influenced by a vast array of physical, climatic, and social factors. Changing climate, fuel buildup due to past suppression, and increasing populations in the wildland-urban interface have all been blamed for the extreme fire seasons and rising suppression expenditures of recent years. With each high-cost year comes a...
Research Plan for Fire Signatures and Detection
NASA Technical Reports Server (NTRS)
2004-01-01
Viewgraphs on the prevention, suppression, and detection of fires aboard a spacecraft is presented. The topics include: 1) Fire Prevention, Detection, and Suppression Sub-Element Products; 2) FPDS Organizing Questions; 3) FPDS Organizing Questions; 4) Signatures, Sensors, and Simulations; 5) Quantification of Fire and Pre-Fire Signatures; 6) Smoke; 7) DAFT Hardware; 8) Additional Benefits of DAFT; 9) Development and Characterization of Sensors 10) Simulation of the Transport of Smoke and Fire Precursors; and 11) FPDS Organizing Questions.
Evaluation and Testing of Rail Transit Undercar Fire Detection and Suppression Systems
DOT National Transportation Integrated Search
1989-08-01
This document presents the results of a comprehensive review and evaluation of transit undercar fire detection and suppression methods. The evaluation of fire detection method resulted in a recommendation that continuous wire type linear thermal dete...
46 CFR 35.40-7 - Carbon dioxide alarm-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 1 2011-10-01 2011-10-01 false Carbon dioxide alarm-T/ALL. 35.40-7 Section 35.40-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL. § 35.40-7 Carbon dioxide alarm—T/ALL. Adjacent to all carbon dioxide fire extinguishing...
46 CFR 97.37-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Carbon dioxide alarm. 97.37-9 Section 97.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN...
46 CFR 95.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide storage. 95.15-20 Section 95.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-20 Carbon dioxide storage. (a) Except as provided in paragraph (b) of this...
46 CFR 78.47-9 - Carbon dioxide alarm.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 3 2011-10-01 2011-10-01 false Carbon dioxide alarm. 78.47-9 Section 78.47-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-9 Carbon dioxide alarm. (a) All carbon dioxide alarms shall be conspicuously identified: “WHEN ALARM...
46 CFR 95.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide storage. 95.15-20 Section 95.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-20 Carbon dioxide storage. (a) Except as provided in paragraph (b) of this...
Chapter 14: Effects of fire suppression and postfire management activities on plant invasions
Matthew L. Brooks
2008-01-01
This chapter explains how various fire suppression and postfire management activities can increase or decrease the potential for plant invasions following fire. A conceptual model is used to summarize the basic processes associated with plant invasions and show how specific fire management activities can be designed to minimize the potential for invasion. The...
Wildfire and drought dynamics destabilize carbon stores of fire-suppressed forests
J. Mason Earles; Malcolm P. North; Matthew D. Hurteau
2014-01-01
Widespread fire suppression and thinning have altered the structure and composition of many forests in the western United States, making them more susceptible to the synergy of large-scale drought and fire events. We examine how these changes affect carbon storage and stability compared to historic fire-adapted conditions. We modeled carbon dynamics under possible...
Richard A. Minnich; Ernesto Franco-Vizcaíno
2009-01-01
Fire suppression in industrialized countries encourages massive smoke emissions from high-intensity fires as a result of two inextricably related processes under current suppression policies: the nonrandom occurrence of vegetation fires in extreme weather states and the anomalous accumulation of spatially homogenous fuels. We propose as an organizing idea that the...
Carol Rice
1995-01-01
Dr. Biswell's approach to fire management balanced fire prevention, suppression, and fuel management. Dr. Biswell maintained that with increased support for fire prevention and fuel management, several profound changes would be anticipated, including a decrease in the number of wildfires, as well as a decrease in requirements for suppression. Interested persons...
Jens T. Stevens; Brandon M. Collins; Jonathan W. Long; Malcolm P. North; Susan J. Prichard; Leland W. Tarnay; Angela M. White
2016-01-01
Fuel treatments in fire-suppressed mixed-conifer forests are designed to moderate potential wildfire behavior and effects. However, the objectives for modifying potential fire effects can vary widely, from improving fire suppression efforts and protecting infrastructure, to reintroducing low-severity fire, to restoring and maintaining variable forest structure and...
Prevention and suppression of metal packing fires.
Roberts, Mark; Rogers, William J; Sam Mannan, M; Ostrowski, Scott W
2003-11-14
Structured packing has been widely used because of large surface area that makes possible columns with high capacity and efficiency. The large surface area also contributes to fire hazards because of hydrocarbon deposits that can easily combust and promote combustion of the thin metal packing materials. Materials of high surface area that can fuel fires include reactive metals, such as titanium, and materials that are not considered combustible, such as stainless steel. Column design and material selection for packing construction is discussed together with employee training and practices for safe column maintenance and operations. Presented also are methods and agents for suppression of metal fires. Guidance for prevention and suppression of metal fires is related to incidents involving packing fires in columns.
Fuel age and fire spread: Natural conditions versus opportunities for fire suppression
Halsey, Richard W.; Keeley, Jon E.; Wilson, Kit
2009-01-01
Wildfires are driven and restrained by an interplay of variables that can lead to many potential outcomes. As every wildland firefighter learns in basic training, the ability of a fire to spread is determined by three basic variables: fuel type and condition, weather, and topography. Fire suppression obviously plays a significant role in determining fire spread as well, so firefighter activity becomes an additional variable.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space. The...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space. The...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space. The...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-30 Alarms. (a) Spaces which are protected by a carbon dioxide... such spaces which will be automatically sounded when the carbon dioxide is admitted to the space. The...
Crystal S. Stonesifer; Dave Calkin; Matthew P. Thompson; Keith D. Stockmann
2016-01-01
Large airtanker use is widespread in wildfire suppression in the United States. The current approach to nationally dispatching the fleet of federal contract airtankers relies on filling requests for airtankers to achieve suppression objectives identified by fire managers at the incident level. In general, demand is met if resources are available, and the...
Synthesis of Fire-Extinguishing Dawsonites
NASA Technical Reports Server (NTRS)
Altman, R. L.
1982-01-01
Simple nonaqueous process synthesizes sodium or potassium, dawsonites effective against hydrocarbon fuel fires. Fire-extinguishing alkali metal dawsonites are prepared using a finely-pulverized equimolar mixture of hydrogen carbonate, or carbonates and aluminum hydroxide heated for 1 to 6 hours under carbon dioxide pressure.
NASA Astrophysics Data System (ADS)
Sá, Ana C. L.; Benali, Akli; Pinto, Renata M. S.; Pereira, José M. C.; Trigo, Ricardo M.; DaCamara, Carlos C.
2014-05-01
Large wildfires are infrequent but account for the most severe environmental, ecological and socio-economic impacts. In recent years Portugal has suffered the impact of major heat waves that fuelled records of burnt area exceeding 400.000ha and 300.000ha in 2003 and 2005, respectively. According to the latest IPCC reports, the frequency and amplitude of summer heat waves over Iberia will very likely increase in the future. Therefore, most climate change studies point to an increase in the number and extent of wildfires. Thus, an increase in both wildfire impacts and fire suppression difficulties is expected. The spread of large wildfires results from a complex interaction between topography, meteorology and fuel properties. Wildfire spread models (e.g. FARSITE) are commonly used to simulate fire growth and behaviour and are an essential tool to understand their main drivers. Additionally, satellite active-fire data have been used to monitor the occurrence, extent, and spread of wildfires. Both satellite data and fire spread models provide different types of information about the spatial and temporal distribution of large wildfires and can potentially be used to support strategic decisions regarding fire suppression resource allocation. However, they have not been combined in a manner that fully exploits their potential and minimizes their limitations. A knowledge gap still exists in understanding how to minimize the impacts of large wildfires, leading to the following research question: What can we learn from past large wildfires in order to mitigate future fire impacts? FIRE-MODSAT is a one-year funded project by the Portuguese Foundation for the Science and Technology (FCT) that is founded on this research question, with the main goal of improving our understanding on the interactions between fire spread and its environmental drivers, to support fire management decisions in an operational context and generate valuable information to improve the efficiency of the fire suppression system. This project proposes to explore an innovative combination of remote sensing and fire spread models in order to 1) better understand the interactions of fire spread drivers that lead to large wildfires; 2) identify the spatio-temporal frames in which large wildfires can be suppressed more efficiently, and 3) explore the essential steps towards an operational use of both tools to assist fire suppression decisions. Preliminary results combine MODIS active-fire data and burn scar perimeters, to derive the main fire spread paths for the 10 largest wildfires that occurred in Portugal between 2001 and 2012. Fire growth and behavior simulations of some of those wildfires are assessed using the active fires data. Results are also compared with the major fire paths to understand the main drivers of fire propagation, through their interactions with topography, vegetation and meteorology. These combined results are also used for spatial and temporal identification of opportunity windows for a more efficient suppression intervention for each fire event. The approach shows promising results, providing a valuable reconstruction of the fire events and retrieval of important parameters related to the complex spread patterns of individual fire events.
46 CFR 131.817 - Carbon dioxide warning signs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide warning signs. 131.817 Section 131.817 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.817 Carbon dioxide warning signs. Each entrance...
46 CFR 131.817 - Carbon dioxide warning signs.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide warning signs. 131.817 Section 131.817 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.817 Carbon dioxide warning signs. Each entrance...
46 CFR 131.817 - Carbon dioxide warning signs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide warning signs. 131.817 Section 131.817 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OFFSHORE SUPPLY VESSELS OPERATIONS Markings for Fire Equipment and Emergency Equipment § 131.817 Carbon dioxide warning signs. Each entrance...
Christina M. Andruk; Norma L. Fowler
2015-01-01
Decades of fire suppression have significantly altered the vegetation structure and composition of savannas, woodlands, and forests. The presence of endangered species and other species of conservation concern in these fire-suppressed systems makes re-introducing fire more challenging. In oak-juniper woodlands of central Texas, we are presented with the challenge of re...
The fire and oak hypothesis: incorporating the influence of deer browsing and canopy gaps
Rachel J. Collins; Walter P. Carson
2003-01-01
A century of fire suppression has altered tree species composition and is a commonly cited cause for the region-wide decline in oak abundance (the fire and oak hypothesis). Other explanations include alterations in canopy gap regimes and deer browsing that operate in conjunction with fire suppression. We examined the interactions among these processes by manipulating...
46 CFR 28.825 - Excess fire detection and protection equipment.
Code of Federal Regulations, 2011 CFR
2011-10-01
...” “CARBON DIOXIDE FIRE SYSTEM” or “FOAM FIRE SYSTEM”, as the case may be; (v) Instructions for the operation... be locked, a key to the space or enclosure shall be in a break-glass-type box conspicuously located...
Balshi, M. S.; McGuire, Anthony David; Duffy, P.; Flannigan, M.; Kicklighter, David W.; Melillo, J.
2009-01-01
The boreal forest contains large reserves of carbon. Across this region, wildfires influence the temporal and spatial dynamics of carbon storage. In this study, we estimate fire emissions and changes in carbon storage for boreal North America over the 21st century. We use a gridded data set developed with a multivariate adaptive regression spline approach to determine how area burned varies each year with changing climatic and fuel moisture conditions. We apply the process-based Terrestrial Ecosystem Model to evaluate the role of future fire on the carbon dynamics of boreal North America in the context of changing atmospheric carbon dioxide (CO2) concentration and climate in the A2 and B2 emissions scenarios of the CGCM2 global climate model. Relative to the last decade of the 20th century, decadal total carbon emissions from fire increase by 2.5–4.4 times by 2091–2100, depending on the climate scenario and assumptions about CO2fertilization. Larger fire emissions occur with warmer climates or if CO2 fertilization is assumed to occur. Despite the increases in fire emissions, our simulations indicate that boreal North America will be a carbon sink over the 21st century if CO2 fertilization is assumed to occur in the future. In contrast, simulations excluding CO2 fertilization over the same period indicate that the region will change to a carbon source to the atmosphere, with the source being 2.1 times greater under the warmer A2 scenario than the B2 scenario. To improve estimates of wildfire on terrestrial carbon dynamics in boreal North America, future studies should incorporate the role of dynamic vegetation to represent more accurately post-fire successional processes, incorporate fire severity parameters that change in time and space, account for human influences through increased fire suppression, and integrate the role of other disturbances and their interactions with future fire regime.
46 CFR 97.37-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 97.37-9 Section 97.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent...
46 CFR 97.37-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 97.37-9 Section 97.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent...
46 CFR 97.37-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 97.37-9 Section 97.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-9 Carbon dioxide and clean agent alarms. Each carbon dioxide or clean agent...
Physical and Chemical Aspects of Fire Suppression in Extraterrestrial Environments
NASA Technical Reports Server (NTRS)
Takahashi, F.; Linteris, G. T.; Katta, V. R.
2001-01-01
A fire, whether in a spacecraft or in occupied spaces on extraterrestrial bases, can lead to mission termination or loss of life. While the fire-safety record of US space missions has been excellent, the advent of longer duration missions to Mars, the moon, or aboard the International Space Station (ISS) increases the likelihood of fire events, with more limited mission termination options. The fire safety program of NASA's manned space flight program is based largely upon the principles of controlling the flammability of on-board materials and greatly eliminating sources of ignition. As a result, very little research has been conducted on fire suppression in the microgravity or reduced-gravity environment. The objectives of this study are: to obtain fundamental knowledge of physical and chemical processes of fire suppression, using gravity and oxygen concentration as independent variables to simulate various extraterrestrial environments, including spacecraft and surface bases in Mars and moon missions; to provide rigorous testing of analytical models, which include comprehensive descriptions of combustion and suppression chemistry; and to provide basic research results useful for technological advances in fire safety, including the development of new fire-extinguishing agents and approaches, in the microgravity environment associated with ISS and in the partial-gravity Martian and lunar environments.
Development of Flexi-Burn™ CFB Power Plant to Meet the Challenge of Climate Change
NASA Astrophysics Data System (ADS)
Hackt, Horst; Fant, Zhen; Seltzert, Andrew; Hotta, Arto; Erikssoni, Timo; Sippu, Ossi
Carbon-dioxide capture and storage (CCS) offers the potential for major reductions in carbon- dioxide emissions of fossil fuel-based power generation in the fairly short term, and oxyfuel combustion is one of the identified CCS technology options. Foster Wheeler (FW) is working on reduction of carbon-dioxide with its integrated Flexi-Burn™ CFB technology. The proven high efficiency circulating fluidized-bed (CFB) technology, when coupled with air separation units and carbon purification units, offers a solution for carbon dioxide reduction both in re-powering and in greenfield power plants. CFB technology has the advantages over pulverized coal technology of a more uniform furnace heat flux, increased fuel flexibility and offers the opportunity to further reduce carbon dioxide emissions by co-firing coal with bio-fuels. Development and design of an integrated Flexi-Bum™ CFB steam generator and balance of plant system was conducted for both air mode and oxyfuel mode. Through proper configuration and design, the same steam generator can be switched from air mode to oxyfuel mode without the need for unit shutdown for modifications. The Flexi-Burn™ CFB system incorporates features to maximize plant efficiency and power output when operating in the oxy-firing mode through firing more fuel in the same boiler.
46 CFR 193.15-5 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2013 CFR
2013-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems, Details § 193.15-5 Quantity, pipe sizes, and discharge rates. (a) General. The amount of carbon dioxide required for each.... A separate supply of carbon dioxide need not be provided for each space protected. The total...
46 CFR 193.15-5 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2014 CFR
2014-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems, Details § 193.15-5 Quantity, pipe sizes, and discharge rates. (a) General. The amount of carbon dioxide required for each.... A separate supply of carbon dioxide need not be provided for each space protected. The total...
46 CFR 97.37-11 - Carbon dioxide warning signs.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Carbon dioxide warning signs. 97.37-11 Section 97.37-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-11 Carbon dioxide warning signs. Each...
46 CFR 97.37-11 - Carbon dioxide warning signs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false Carbon dioxide warning signs. 97.37-11 Section 97.37-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-11 Carbon dioxide warning signs. Each...
46 CFR 97.37-11 - Carbon dioxide warning signs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Carbon dioxide warning signs. 97.37-11 Section 97.37-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 97.37-11 Carbon dioxide warning signs. Each...
46 CFR 193.15-50 - Clean agent systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
... PROTECTION EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems, Details § 193.15-50 Clean agent... carbon dioxide fire extinguishing system. [USCG-2006-24797, 77 FR 33893, June 7, 2012] ...
46 CFR 193.15-50 - Clean agent systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
... PROTECTION EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems, Details § 193.15-50 Clean agent... carbon dioxide fire extinguishing system. [USCG-2006-24797, 77 FR 33893, June 7, 2012] ...
FIRESCOPE: a new concept in multiagency fire suppression coordination
Richard A. Chase
1980-01-01
FIRESCOPE is a system developed to improve the capability of firefighting agencies in southern California in allocating and managing fire suppression resources. The system provides an effective and efficient solution to operational coordination requirements and problems of the major fire protection agencies serving the southern California urban-wildland complex. Major...
The Effect of Extinguishing Agents on Burning Sonobuoys Containing Lithium-Sulfur Dioxide Batteries
1989-09-01
components and the JP-5. In addition, the types of extinguish- ment materials, such as carbor spheres, that have some degree of success on metal fires , would...NWC TP 6571, publication UNCLASSIFIED.) 8. John F. Riley. "Na-X, a New Fire Extinguishing Agent for Metal Fires ," Fire Technology, Vol. 10, No. 4
Fire, humans and landscape. Is there a connection?
NASA Astrophysics Data System (ADS)
Valese, Eva; Ascoli, Davide; Conedera, Marco; Held, Alex
2013-04-01
Fire evolved on the earth under the direct influence of climate and the accumulation of burnable biomass at various times and spatial scales. As a result, fire regimes depend not only on climatic and biological factors, but also greatly reflect the cultural background of how people do manage ecosystems and fire. A new awareness among scientists and managers has been rising about the ecological role of fire and the necessity to understand its past natural and cultural dynamics in different ecosystems, in order to preserve present ecosystem functionality and minimize management costs and negative impacts. As a consequence we assisted in the last decades to a general shift from the fire control to the fire management approach, where fire prevention, fire danger rating, fire ecology, fire pre-suppression and suppression strategies are fully integrated in the landscape management. Nowadays, a large number of authors recognize that a total suppression strategy, as the one adopted during last decades, leads to a fire paradox: the more we fight for putting out all fires, the more extreme events occur and cause long term damages. The aim of this review is to provide a state of art about the connection between fire, humans and landscape, along time and space. Negative and positive impacts on ecosystem services and values are put in evidence, as well as their incidence on human aptitude to fire use as to fire suppression. In order to capture a consistent fragment of fire history, palaeofires and related palynological studies are considered. They enable a valuable, even if partial, look at the millenary fire regime. Actual strategies and future directions are described in order to show what are the alternatives for living with fire, since removing completely this disturbance from earth is not a option, nor feasible neither advisable. Examples from the world, in particular from the Alps and the Mediterranean basin, are shown for better illustrating the signature of anthropogenic fire on landscapes.
Roy Headley
1916-01-01
The increasing effectiveness of suppression practice is shown by the fact that in 1915 fire suppression cost one-third as much as in 1914, and damage to Government property was kept down to one-fourth the 1914 figure. The seasons were approximately equal in danger. Is further progress to be expected?
NASA Technical Reports Server (NTRS)
Ruff, Gary A.
2011-01-01
The Fire Prevention, Detection, and Suppression (FPDS) project is a technology development effort within the Exploration Technology Development Program of the Exploration System Missions Directorate (ESMD) that addresses all aspects of fire safety aboard manned exploration systems. The overarching goal for work in the FPDS area is to develop technologies that will ensure crew health and safety on exploration missions by reducing the likelihood of a fire, or, if one does occur, minimizing the risk to the crew, mission, or system. This is accomplished by addressing the areas of (1) fire prevention and material flammability, (2) fire signatures and detection, and (3) fire suppression and response. This report describes the outcomes of this project from the formation of the Exploration Technology Development Program (ETDP) in October 2005 to September 31, 2010 when the Exploration Technology Development Program was replaced by the Enabling Technology Development and Demonstration Program. NASA s fire safety work will continue under this new program and will build upon the accomplishments described herein.
46 CFR 35.40-7 - Carbon dioxide and clean agent alarms-T/ALL.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 1 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms-T/ALL. 35.40-7 Section 35.40-7 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY TANK VESSELS OPERATIONS Posting and Marking Requirements-TB/ALL § 35.40-7 Carbon dioxide and clean agent alarms—T/ALL. Each carbon dioxide or clean agent fire extinguishing alarm...
Risks and issues in fire safety on the Space Station
NASA Technical Reports Server (NTRS)
Friedman, Robert
1993-01-01
A fire in the inhabited portion of a spacecraft is a greatly feared hazard, but fire protection in space operations is complicated by two factors. First, the spacecraft cabin is an enclosed volume, which limits the resources for fire fighting and the options for crew escape. Second, an orbiting spacecraft experiences a balance of forces, creating a near-zero-gravity (microgravity) environment that profoundly affects the characteristics of fire initiation, spread, and suppression. The current Shuttle Orbiter is protected by a fire-detection and suppression system whose requirements are derived of necessity from accepted terrestrial and aircraft standards. While experience has shown that Shuttle fire safety is adequate, designers recognize that improved systems to respond specifically to microgravity fire characteristics are highly desirable. Innovative technology is particularly advisable for the Space Station, a forthcoming space community with a complex configuration and long-duration orbital missions, in which the effectiveness of current fire-protection systems is unpredictable. The development of risk assessments to evaluate the probabilities and consequences of fire incidents in spacecraft are briefly reviewed. It further discusses the important unresolved issues and needs for improved fire safety in the Space Station, including those of material selection, spacecraft atmospheres, fire detection, fire suppression, and post-fire restoration.
Stennis acquires new ladder truck
2009-10-20
The Stennis Space Center Fire Department added to its fire-fighting capabilities with acquisition of a new emergency response vehicle, Ladder-1, for use on-site. The E-One HP78 Aerial Truck is a combination aerial ladder and fire suppression unit and is designed with the latest safety technology. Featuring a 78-foot ladder and a pumping capability of 1,500 gallons per minute, the new truck provides firefighters with a tremendous rescue and fire suppression tool, Stennis Fire Chief Clark Smith said.
NASA Technical Reports Server (NTRS)
Clements, Anna L.
2011-01-01
NASA is developing a Fine Water Mist Portable Fire Extinguisher for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. Fine Water Mist extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. From a flight hardware design perspective, the fine water mist fire extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface has been under development for several years. It has gone through several design iterations, and has been part of more than 400 fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements specifically for the tank. The nozzle requirements drive a tank pressure that is 2-5 times higher than any commercially available water mist systems. Microgravity requires deliberate separation of gas and water, facilitated by a bladder, a diaphragm, a piston, or separate tanks. This paper will describe the design details of the tank and the nozzle, and discuss the trade studies that informed the decisions to select the tank and nozzle configuration.
Ultrafine and respirable particle exposure during vehicle fire suppression
Fent, Kenneth W.
2015-01-01
Vehicle fires are a common occurrence, yet few studies have reported exposures associated with burning vehicles. This article presents an assessment of firefighters’ potential for ultrafine and respirable particle exposure during vehicle fire suppression training. Fires were initiated within the engine compartment and passenger cabins of three salvaged vehicles, with subsequent water suppression by fire crews. Firefighter exposures were monitored with an array of direct reading particle and air quality instruments. A flexible metallic duct and blower drew contaminants to the instrument array, positioned at a safe distance from the burning vehicles, with the duct inlet positioned at the nozzle operator’s shoulder. The instruments measured the particle number, active surface area, respirable particle mass, photoelectric response, aerodynamic particle size distributions, and air quality parameters. Although vehicle fires were suppressed quickly (<10 minutes), firefighters may be exposed to short duration, high particle concentration episodes during fire suppression, which are orders of magnitude greater than the ambient background concentration. A maximum transient particle concentration of 1.21 × 107 particles per cm3, 170 mg m−3 respirable particle mass, 4700 μm2 cm−3 active surface area and 1400 (arbitrary units) in photoelectric response were attained throughout the series of six fires. Expressed as fifteen minute time-weighted averages, engine compartment fires averaged 5.4 × 104 particles per cm3, 0.36 mg m−3 respirable particle mass, 92 μm2 cm−3 active particle surface area and 29 (arbitrary units) in photoelectric response. Similarly, passenger cabin fires averaged 2.04 × 105 particles per cm3, 2.7 mg m−3 respirable particle mass, 320 μm2 cm−3 active particle surface area, and 34 (arbitrary units) in photoelectric response. Passenger cabin fires were a greater potential source of exposure than engine compartment fires. The wind direction and the relative position of the fire crew to the stationary burning vehicle played a primary role in fire crews’ potential for exposure. We recommend that firefighters wear self-contained breathing apparatus during all phases of the vehicle fire response to significantly reduce their potential for particulate, vapor, and gaseous exposures. PMID:26308547
Ultrafine and respirable particle exposure during vehicle fire suppression.
Evans, Douglas E; Fent, Kenneth W
2015-10-01
Vehicle fires are a common occurrence, yet few studies have reported exposures associated with burning vehicles. This article presents an assessment of firefighters' potential for ultrafine and respirable particle exposure during vehicle fire suppression training. Fires were initiated within the engine compartment and passenger cabins of three salvaged vehicles, with subsequent water suppression by fire crews. Firefighter exposures were monitored with an array of direct reading particle and air quality instruments. A flexible metallic duct and blower drew contaminants to the instrument array, positioned at a safe distance from the burning vehicles, with the duct inlet positioned at the nozzle operator's shoulder. The instruments measured the particle number, active surface area, respirable particle mass, photoelectric response, aerodynamic particle size distributions, and air quality parameters. Although vehicle fires were suppressed quickly (<10 minutes), firefighters may be exposed to short duration, high particle concentration episodes during fire suppression, which are orders of magnitude greater than the ambient background concentration. A maximum transient particle concentration of 1.21 × 10(7) particles per cm(3), 170 mg m(-3) respirable particle mass, 4700 μm(2) cm(-3) active surface area and 1400 (arbitrary units) in photoelectric response were attained throughout the series of six fires. Expressed as fifteen minute time-weighted averages, engine compartment fires averaged 5.4 × 10(4) particles per cm(3), 0.36 mg m(-3) respirable particle mass, 92 μm(2) cm(-3) active particle surface area and 29 (arbitrary units) in photoelectric response. Similarly, passenger cabin fires averaged 2.04 × 10(5) particles per cm(3), 2.7 mg m(-3) respirable particle mass, 320 μm(2) cm(-3) active particle surface area, and 34 (arbitrary units) in photoelectric response. Passenger cabin fires were a greater potential source of exposure than engine compartment fires. The wind direction and the relative position of the fire crew to the stationary burning vehicle played a primary role in fire crews' potential for exposure. We recommend that firefighters wear self-contained breathing apparatus during all phases of the vehicle fire response to significantly reduce their potential for particulate, vapor, and gaseous exposures.
Using prescribed fire to reduce the risk of large wildfires: A break-even analysis
James M. Saveland
1987-01-01
Nearly all wildfires are extinguished when they are still small. The 3-5% that get out of control cause 95% of all wildfire-related costs and damages (Dodge 1972, Wilson 1985). There are two ways to deal with these problem fires. One practice is to limit fire by suppressing fires as soon as possible after they are detected. Increasing the capability of suppression...
Bibliography on aircraft fire hazards and safety. Volume 2: Safety. Part 1: Key numbers 1 to 524
NASA Technical Reports Server (NTRS)
Pelouch, J. J., Jr. (Compiler); Hacker, P. T. (Compiler)
1974-01-01
Bibliographic citations are presented to describe and define aircraft safety methods, equipment, and criteria. Some of the subjects discussed are: (1) fire and explosion suppression using whiffle balls, (2) ultraviolet flame detecting sensors, (3) evaluation of flame arrestor materials for aircraft fuel systems, (4) crash fire prevention system for supersonic commercial aircraft, and (5) fire suppression for aerospace vehicles.
46 CFR 193.15-5 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2010 CFR
2010-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-5 Quantity, pipe sizes, and discharge rates. (a) General. The amount of carbon dioxide required for each space shall be... supply of carbon dioxide need not be provided for each space protected. The total available supply shall...
46 CFR 95.15-5 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2010 CFR
2010-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-5 Quantity, pipe sizes, and discharge rates. (a) General. The amount of carbon dioxide required for each space shall be... supply of carbon dioxide need not be provided for each space protected. The total available supply shall...
46 CFR 95.15-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2010 CFR
2010-10-01
... MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-90.... The number of pounds of carbon dioxide shall be equal to the gross volume of the boilerroom taken to... internal combustion machinery is installed, the number of pounds of carbon dioxide required shall be equal...
46 CFR 193.15-5 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2011 CFR
2011-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15-5 Quantity, pipe sizes, and discharge rates. (a) General. The amount of carbon dioxide required for each space shall be... supply of carbon dioxide need not be provided for each space protected. The total available supply shall...
46 CFR 95.15-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2012 CFR
2012-10-01
... MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-90.... The number of pounds of carbon dioxide shall be equal to the gross volume of the boilerroom taken to... internal combustion machinery is installed, the number of pounds of carbon dioxide required shall be equal...
46 CFR 95.15-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2011 CFR
2011-10-01
... MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-90.... The number of pounds of carbon dioxide shall be equal to the gross volume of the boilerroom taken to... internal combustion machinery is installed, the number of pounds of carbon dioxide required shall be equal...
46 CFR 95.15-5 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2012 CFR
2012-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-5 Quantity, pipe sizes, and discharge rates. (a) General. The amount of carbon dioxide required for each space shall be... supply of carbon dioxide need not be provided for each space protected. The total available supply shall...
46 CFR 95.15-5 - Quantity, pipe sizes, and discharge rates.
Code of Federal Regulations, 2011 CFR
2011-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-5 Quantity, pipe sizes, and discharge rates. (a) General. The amount of carbon dioxide required for each space shall be... supply of carbon dioxide need not be provided for each space protected. The total available supply shall...
46 CFR 78.47-11 - Carbon dioxide warning signs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Carbon dioxide warning signs. 78.47-11 Section 78.47-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-11 Carbon dioxide warning signs. Each entrance to a space...
46 CFR 78.47-11 - Carbon dioxide warning signs.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Carbon dioxide warning signs. 78.47-11 Section 78.47-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-11 Carbon dioxide warning signs. Each entrance to a space...
46 CFR 196.37-8 - Carbon dioxide warning signs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Carbon dioxide warning signs. 196.37-8 Section 196.37-8 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-8 Carbon dioxide warning signs. Each entrance to a...
46 CFR 196.37-8 - Carbon dioxide warning signs.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Carbon dioxide warning signs. 196.37-8 Section 196.37-8 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-8 Carbon dioxide warning signs. Each entrance to a...
46 CFR 78.47-11 - Carbon dioxide warning signs.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Carbon dioxide warning signs. 78.47-11 Section 78.47-11 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS OPERATIONS Markings for Fire and Emergency Equipment, Etc. § 78.47-11 Carbon dioxide warning signs. Each entrance to a space...
46 CFR 196.37-8 - Carbon dioxide warning signs.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Carbon dioxide warning signs. 196.37-8 Section 196.37-8 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-8 Carbon dioxide warning signs. Each entrance to a...
Potential climate change impacts on fire intensity and key wildfire suppression thresholds in Canada
NASA Astrophysics Data System (ADS)
Wotton, B. M.; Flannigan, M. D.; Marshall, G. A.
2017-09-01
Much research has been carried out on the potential impacts of climate change on forest fire activity in the boreal forest. Indeed, there is a general consensus that, while change will vary regionally across the vast extent of the boreal, in general the fire environment will become more conducive to fire. Land management agencies must consider ways to adapt to these new conditions. This paper examines the impact of that changed fire environment on overall wildfire suppression capability. We use multiple General Circulation Models and carbon emission pathways to generate future fire environment scenarios for Canada’s forested region. We then use these scenarios with the Canadian Forest Fire Behaviour Prediction System and spatial coverages of the current forest fuel composition across the landscape to examine potential variation in key fire behaviour outputs that influence whether fire management resources can effectively suppress fire. Specifically, we evaluate how the potential for crown fire occurrence and active growth of fires changes with the changing climate. We also examine future fire behaviour through the lens of operational fire intensity thresholds used to guide decisions about resources effectiveness. Results indicate that the proportion of days in fire seasons with the potential for unmanageable fire will increase across Canada’s forest, more than doubling in some regions in northern and eastern boreal forest.
Clark, Victoria R; Herzog, Howard J
2014-07-15
On September 20, 2013, the US Environmental and Protection Agency (EPA) proposed a revised rule for "Standards of Performance for Greenhouse Gas Emissions from New Stationary Sources: Electric Utility Generating Units". These performance standards set limits on the amount of carbon dioxide (CO2) that can be emitted per megawatt-hour (MWh) of electricity generation from new coal-fired and natural gas-fired power plants built in the US. These limits were based on determinations of "best system of emission reduction (BSER) adequately demonstrated". Central in this determination was evaluating whether Carbon Dioxide Capture and Storage (CCS) qualified as BSER. The proposed rule states that CCS qualifies as BSER for coal-fired generation but not for natural gas-fired generation. In this paper, we assess the EPA's analysis that resulted in this determination. We are not trying to judge what the absolute criteria are for CCS as the BSER but only the relative differences as related to coal- vs natural gas-fired technologies. We conclude that there are not enough differences between "base load" coal-fired and natural gas-fired power plants to justify the EPA's determination that CCS is the BSER for coal-fired power plants but not for natural gas-fired power plants.
46 CFR 189.55-5 - Plans and specifications required for new construction.
Code of Federal Regulations, 2014 CFR
2014-10-01
..., the arrangement of the alarm and extinguishing systems, the fire extinguishers, means of access to... other fire control features. (3) Details of alarm systems. (4) Details of extinguishing systems, including fire mains, carbon dioxide, clean agent, foam, and sprinkling systems. (e) Marine engineering. For...
46 CFR 189.55-5 - Plans and specifications required for new construction.
Code of Federal Regulations, 2013 CFR
2013-10-01
..., the arrangement of the alarm and extinguishing systems, the fire extinguishers, means of access to... other fire control features. (3) Details of alarm systems. (4) Details of extinguishing systems, including fire mains, carbon dioxide, clean agent, foam, and sprinkling systems. (e) Marine engineering. For...
NASA Astrophysics Data System (ADS)
Kim, S.; Brioude, J.; Hilboll, A.; Richter, A.; Gleason, J. F.; Burrows, J. P.; Ryerson, T. B.; Peischl, J. W.; Holloway, J.; Lee, S.; Frost, G. J.; McKeen, S. A.; Trainer, M.
2009-12-01
During August-October 2006, there were many fire events in the U.S., including a month-long fire in Los Padres National Forest in California and numerous fires in the southeastern U.S. The OMI instrument onboard NASA's Aura satellite, the MODIS instrument on NASA's Terra satellite, and instruments on the NOAA GOES satellites clearly detected fire plumes during this period, opening the possibility of using trace gas and aerosol measurements from satellites to improve bottom-up emission estimates from wildfires. WRF-Chem model simulations of U.S. air quality without bottom-up fire emissions underestimated satellite-observed nitrogen dioxide columns substantially over fire-impacted regions during this time period. In this presentation, nitrogen dioxide columns simulated from the model including the wildfire emissions will be compared with the satellite retrievals and uncertainties in the bottom-up fire NOx emissions will be discussed. In addition, the sensitivities of satellite retrievals to aerosols resulting from these fires will be shown. The satellite NO2 columns will also be tested with aircraft observations made over the Texas region during September-October 2006 as part of the TexAQS/GoMACCS field campaign.
Evaluation of CO2, N2 and He as Fire Suppression Agents in Microgravity
NASA Technical Reports Server (NTRS)
Ruff, Gary A.; Hicks, Michael; Pettegrew, Richard
2004-01-01
The U.S. modules of the International Space Station use gaseous CO2 as the fire extinguishing agent. This was selected as a result of extensive experience with CO2 as a fire suppressant in terrestrial applications, trade studies on various suppressants, and experiments. The selection of fire suppressants and suppression strategies for NASA s Lunar and Martian exploration missions will be based on the same studies and normal-gravity data unless reduced gravity fire suppression data is obtained. In this study, the suppressant agent concentrations required to extinguish a flame in low velocity convective flows within the 20-sec of low gravity on the KC-135 aircraft were investigated. Suppressant gas mixtures of CO2, N2, and He with the balance being oxygen/nitrogen mixtures with either 21% or 25% O2 were used to suppress flames on a 19-mm diameter PMMA cylinder in reduced gravity. For each of the suppressant mixtures, limiting concentrations were established that would extinguish the flame at any velocity. Similarly, concentrations were established that would not extinguish the flame. The limiting concentrations were generally consistent with previous studies but did suggest that geometry had an effect on the limiting conditions. Between the extinction and non-extinction limits, the suppression characteristics depended on the extinguishing agent, flow velocity, and O2 concentration. The limiting velocity data from the CO2, He, and N2 suppressants were well correlated using an effective mixture enthalpy per mole of O2, indicating that all act via O2 displacement and cooling mechanisms. In reduced gravity, the agent concentration required to suppress the flames increased as the velocity increased, up to approximately 10 cm/s (the maximum velocity evaluated in this experiment). The effective enthalpy required to extinguish flames at velocities of 10 cm/s is approximately the same as the concentrations in normal gravity. A computational study is underway to further evaluate these findings.
Wood crib fire free burning test in ISO room
NASA Astrophysics Data System (ADS)
Qiang, Xu; Griffin, Greg; Bradbury, Glenn; Dowling, Vince
2006-04-01
In the research of application potential of water mist fire suppression system for fire fighting in train luggage carriage, a series of experiments were conducted in ISO room on wood crib fire with and without water mist actuation. The results of free burn test without water mist suppression are used as reference in evaluating the efficiency of water mist suppression system. As part of the free burn test, several tests have been done under the hood of ISO room to calibrate the size of the crib fire and these tests can also be used in analyzing the wall effect in room fire hazard. In these free burning experiments, wood cribs of four sizes under the hood were tested. The temperature of crib fire, heat flux around the fire, gas concentration in hood of ISO room were measured in the experiments and two sets of thermal imaging system were used to get the temperature distribution and the typical shape of the free burning flames. From the experiments, the radiation intensity in specific positions around the fire, the effective heat of combustion, mass loss, oxygen consumption rate for different sizes of fire, typical structure of the flame and self extinguishment time was obtained for each crib size.
Mountains, fire, fire suppression, and the carbon cycle in the western United States
David Schimel
2004-01-01
Most mountain regions in the western United States are covered by forests, which are for the most part recovering from historical harvesting and have been experiencing active fire suppression over approximately the past 100 years (Tilman and others 2000). Whereas many western landscapes are currently perceived as pristine natural systems, the Rockies, Sierra Nevada,...
Costs of fire suppression forces based on cost-aggregation approach
Gonz& aacute; lez-Cab& aacute; Armando n; Charles W. McKetta; Thomas J. Mills
1984-01-01
A cost-aggregation approach has been developed for determining the cost of Fire Management Inputs (FMls)-the direct fireline production units (personnel and equipment) used in initial attack and large-fire suppression activities. All components contributing to an FMI are identified, computed, and summed to estimate hourly costs. This approach can be applied to any FMI...
Hari Katuwal; Christopher J. Dunn; David E. Calkin
2017-01-01
Currently, limited research on large-fire suppression effectiveness suggests fire managers may over-allocate resources relative to values to be protected. Coupled with observations that weather may be more important than resource abundance to achieve control objectives, resource use may be driven more by risk aversion than efficiency. To explore this potential, we...
NASA Technical Reports Server (NTRS)
Clements, Anna L.; Carlile, Christie; Graf, John; Young, Gina
2011-01-01
NASA is developing a Fine Water Mist (FWM) Portable Fire Extinguisher (PFE) for use on the International Space Station. The International Space Station presently uses two different types of fire extinguishers: a water foam extinguisher in the Russian Segment, and a carbon dioxide extinguisher in the US Segment and Columbus and Kibo pressurized elements. Changes in emergency breathing equipment make Fine Water Mist operationally preferable. Supplied oxygen breathing systems allow for safe discharge of a carbon dioxide fire extinguisher, without concerns of the crew inhaling unsafe levels of carbon dioxide. But the Portable Breathing Apparatus (PBA) offers no more than 15 minutes of capability, and continued use of hose based supplied oxygen system increases the oxygen content in a fire situation. NASA has developed a filtering respirator cartridge for use in a fire environment. It is qualified to provide up to 90 minutes of capability, and because it is a filtering respirator it does not add oxygen to the environment. The fire response respirator cartridge does not filter carbon dioxide (CO2), so a crew member discharging a CO2 fire extinguisher while wearing this filtering respirator would be at risk of inhaling unsafe levels of CO2. FWM extinguishes a fire without creating a large volume of air with reduced oxygen and elevated CO2. The following paper will discuss the unique functional and performance requirements that have been levied on the FWM PFE. In addition, the NASA ISS specific fire standards will be described which were developed to establish acceptable extinguisher performance. The paper will also discuss the flight hardware design. The fin e water mist fire extinguisher has two major elements: (1) the nozzle and crew interface, and (2) the tank. The nozzle and crew interface have been under development for several years. They have gone through several design iterations, and have been part of more than 400 fire challenge and spray characterizations. The crew and vehicle interface aspects of the design will use the heritage of the CO2 based Portable Fire Extinguisher, to minimize the disruption to the crew and integration impacts to the ISS. The microgravity use environment of the system poses a set of unique design requirements specifically for the tank. The nozzle requirements drive a tank pressure that is 2-5 times higher than any commercially available water mist systems. Microgravity requires deliberate separation of gas and water, facilitated by a bladder, a diaphragm, a piston, or separate tanks. This paper will describe status of the project to date, the design details of the tank and the nozzle, and discuss the trade studies that informed the decisions to select the tank and nozzle configuration.
46 CFR 193.15-90 - Installations contracted for prior to March 1, 1968.
Code of Federal Regulations, 2010 CFR
2010-10-01
...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15... used in lieu of discharge nozzles for such systems. The number of pounds of carbon dioxide shall be... carbon dioxide required shall be equal to the gross volume of the space taken to the under side of the...
46 CFR 76.15-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2010 CFR
2010-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-90 Installations... number of pounds of carbon dioxide shall be equal to the gross volume of the boiler room taken to the top... combustion machinery is installed, the number of pounds of carbon dioxide required shall be equal to the...
46 CFR 76.15-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2014 CFR
2014-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-90 Installations... number of pounds of carbon dioxide shall be equal to the gross volume of the boiler room taken to the top... combustion machinery is installed, the number of pounds of carbon dioxide required shall be equal to the...
46 CFR 76.15-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2012 CFR
2012-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-90 Installations... number of pounds of carbon dioxide shall be equal to the gross volume of the boiler room taken to the top... combustion machinery is installed, the number of pounds of carbon dioxide required shall be equal to the...
46 CFR 193.15-90 - Installations contracted for prior to March 1, 1968.
Code of Federal Regulations, 2011 CFR
2011-10-01
...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 193.15... used in lieu of discharge nozzles for such systems. The number of pounds of carbon dioxide shall be... carbon dioxide required shall be equal to the gross volume of the space taken to the under side of the...
46 CFR 193.15-90 - Installations contracted for prior to March 1, 1968.
Code of Federal Regulations, 2014 CFR
2014-10-01
...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems... used in lieu of discharge nozzles for such systems. The number of pounds of carbon dioxide shall be... carbon dioxide required shall be equal to the gross volume of the space taken to the under side of the...
46 CFR 76.15-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2011 CFR
2011-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-90 Installations... number of pounds of carbon dioxide shall be equal to the gross volume of the boiler room taken to the top... combustion machinery is installed, the number of pounds of carbon dioxide required shall be equal to the...
46 CFR 193.15-90 - Installations contracted for prior to March 1, 1968.
Code of Federal Regulations, 2013 CFR
2013-10-01
...) OCEANOGRAPHIC RESEARCH VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide and Clean Agent Extinguishing Systems... used in lieu of discharge nozzles for such systems. The number of pounds of carbon dioxide shall be... carbon dioxide required shall be equal to the gross volume of the space taken to the under side of the...
46 CFR 76.15-90 - Installations contracted for prior to November 19, 1952.
Code of Federal Regulations, 2013 CFR
2013-10-01
... VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 76.15-90 Installations... number of pounds of carbon dioxide shall be equal to the gross volume of the boiler room taken to the top... combustion machinery is installed, the number of pounds of carbon dioxide required shall be equal to the...
46 CFR 196.37-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Carbon dioxide and clean agent alarms. 196.37-9 Section 196.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide and clean agent alarms. Each extinguishing system using...
46 CFR 196.37-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Carbon dioxide and clean agent alarms. 196.37-9 Section 196.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide and clean agent alarms. Each extinguishing system using...
46 CFR 196.37-9 - Carbon dioxide and clean agent alarms.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Carbon dioxide and clean agent alarms. 196.37-9 Section 196.37-9 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS OPERATIONS Markings for Fire and Emergency Equipment, etc. § 196.37-9 Carbon dioxide and clean agent alarms. Each extinguishing system using...
Kuwaiti oil fires — Air quality monitoring
NASA Astrophysics Data System (ADS)
Amin, Mohamed B.; Husain, Tahir
Just before the Gulf War was concluded in early March 1991, more than 700 wells in Kuwaiti oil fields were set on fire. About 6 million barrels per day of oil were lost in flames and a large number of pools and lakes were formed. Burning wells in Kuwait emitted several thousand tons of gases such as sulfur dioxide, carbon monoxide, hydrogen sulfide, carbon dioxide, and the oxides of nitrogen, as well as particulate matter, on a daily basis containing partially burned hydrocarbons and metals, all of which were potential for affecting human health and vegetation growth. This paper summarizes the real-time measurements of various gaseous pollutants in the Eastern Province of Saudi Arabia in Dhahran, Abqaiq, Rahimah, Jubail and Tanajib. The statistics on monthly variation of gaseous pollutants showed that pollution concentration in general was high in May 1991. The levels of typical pollutants such as sulfur dioxide (SO 2), carbon monoxide (CO) and nitrogen dioxide (NO 2) in the ambient air were much lower than the permissible limits defined in the Meteorology and Environmental Protection Agency (MEPA) standards. The pollutants measured during the Kuwaiti Oil Fires were compared with the corresponding values measured in the previous year. The comparison shows that although the concentration of gaseous pollutants were within the MEPA limits, during the period of oil well fires, the concentration level increased persistently which might have been harmful for human health. The harmful effects of the major pollutants on human health and vegetation are also briefly discussed in the paper.
Iriana, Windy; Tonokura, Kenichi; Inoue, Gen; Kawasaki, Masahiro; Kozan, Osamu; Fujimoto, Kazuki; Ohashi, Masafumi; Morino, Isamu; Someya, Yu; Imasu, Ryuichi; Rahman, Muhammad Arif; Gunawan, Dodo
2018-05-31
Tropical peatlands in Indonesia have been disturbed over decades and are a source of carbon dioxide (CO 2 ) into the atmosphere by peat respiration and peatland fire. With a portable solar spectrometer, we have performed measurements of column-averaged CO 2 dry-air molar mixing ratios, XCO 2 , in Palangka Raya, Indonesia, and quantify the emission dynamics of the peatland with use of the data for weather, fire hotspot, ground water table, local airport operation visibility and weather radar images. Total emission of CO 2 from surface and underground peat fires as well as from peatland ecosystem is evaluated by day-to-day variability of XCO 2 . We found that the peatland fire and the net ecosystem CO 2 exchange contributed with the same order of magnitude to the CO 2 emission during the non-El Niño Southern Oscillation year of July 2014-August 2015.
NASA Astrophysics Data System (ADS)
Sheehan, T.; Bachelet, D. M.; Ferschweiler, K.
2016-12-01
For Oregon and Washington west of the Cascade Mountain crest, results from the MC2 global dynamic vegetation model have projected a shift in potential vegetation type from predominantly conifer to predominantly mixed forest over the 21st century, with a shift from mixed to conifer in some areas. Carbon stocks have been projected to fall over this period. We ran MC2 using the CCSM4 RCP 8.5 climate future downscaled to 2.5 arc minute resolution with 5 different configurations: no fire; assumed ignitions without fire suppression; assumed ignitions with fire suppression; assumed ignitions with fire suppression and with CO2 concentration held at the preindustrial level; and stochastic ignitions without fire suppression. Results show that vegetation change is the result of climate change alone, while carbon is influenced by both fire occurrence and CO2-induced increased water use efficiency. While model results do not indicate a large change in carbon dynamics concomitant with the shift in vegetation, it is reasonable to expect that a change in conditions resulting in such a change in vegetation type would stress the existing vegetation resulting in some mortality and loss of live carbon.
A model-based framework to evaluate alternative wildfire suppression strategies
Karin L. Riley; Matthew P. Thompson; Joe H. Scott; Julie W. Gilbertson-Day
2018-01-01
The complexity and demands of wildland firefighting in the western U.S. have increased over recent decades due to factors including the expansion of the wildland-urban interface, lengthening fire seasons associated with climate change, and changes in vegetation due to past fire suppression and timber harvest. In light of these changes, the use of more wildland fire on...
Estimating cost of large-fire suppression for three Forest Service regions
Eric L. Smith; Gonz& aacute; lez-Cab& aacute; n Armando
1987-01-01
The annual costs attributable to large fire suppression in three Forest Service Regions (1970-1981) were estimated as a function of fire perimeters using linear regression. Costs calculated on a per chain of perimeterbasis were highest for the Pacific Northwest Region, next highest for the Northern Region, and lowest for the Intermountain Region. Recent costs in real...
23. FIRE SUPPRESSION SYSTEM PIPE, 'GRINNELL VALVE', 'VICTROLIC COUPLING,' AND ...
23. FIRE SUPPRESSION SYSTEM PIPE, 'GRINNELL VALVE', 'VICTROLIC COUPLING,' AND ALARM AT THE REAR OF BAY NO. 5. - Barstow-Daggett Airport, Hangar Shed No. 4, 39500 National Trails Highway, Daggett, San Bernardino County, CA
NASA Astrophysics Data System (ADS)
Trouet, V.; Taylor, A. H.; Skinner, C. N.; Stephens, S.
2016-12-01
In California, large wildfires cause significant socio-ecological impacts and they incur high federal funding costs for fire suppression. Future fire activity is projected to increase with climate change, but anthropogenic effects can modulate or even override climatic effects causing large uncertainty in fire projections. We developed a 415-year fire history record (1600-2015 CE) based on tree-ring fire-scar data from 29 sites throughout the Sierra Nevada, California. Changes in socio-ecological systems from the Native American to the current period drove large historical fire regime shifts in our record and socio-ecological conditions amplified and buffered fire response to climate. Fire activity was highest and fire-climate relationships were strongest after Native American depopulation - following mission establishment ca. 1775 CE - reduced the self-limiting effect of Native American burns on fire spread. With the Gold Rush and Euro-American immigration (ca. 1865 CE), area burned declined and the strong multidecadal relationship between temperature and fire decayed and then disappeared after implementation of fire suppression (ca. 1900 CE). The past anthropogenic modulation of fire-climate relationships underscores the need for nuanced representations of human-fire interactions to improve the skill of future fire-climate projections. In California, large wildfires cause significant socio-ecological impacts and they incur high federal funding costs for fire suppression. Future fire activity is projected to increase with climate change, but anthropogenic effects can modulate or even override climatic effects causing large uncertainty in fire projections. We developed a 415-year fire history record (1600-2015 CE) based on tree-ring fire-scar data from 29 sites throughout the Sierra Nevada, California. Changes in socio-ecological systems from the Native American to the current period drove large historical fire regime shifts in our record and socio-ecological conditions amplified and buffered fire response to climate. Fire activity was highest and fire-climate relationships were strongest after Native American depopulation - following mission establishment ca. 1775 CE - reduced the self-limiting effect of Native American burns on fire spread. With the Gold Rush and Euro-American immigration (ca. 1865 CE), area burned declined and the strong multidecadal relationship between temperature and fire decayed and then disappeared after implementation of fire suppression (ca. 1900 CE). The past anthropogenic modulation of fire-climate relationships underscores the need for nuanced representations of human-fire interactions to improve the skill of future fire-climate projections.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ehleringer, James; Randerson, James; Lai, Chun-Ta
The objective of the proposed research was to collect data and develop models to improve our understanding of the role of drought and fire impacts on the terrestrial carbon cycle in the western US, including impacts associated with urban systems as they impacted regional carbon cycles. Using data we collected and a synthesis of other measurements, we developed new ways (a) to evaluate the representation of drought stress and fire emissions in the Community Land Model, (b) to model net ecosystem exchange combining ground level atmospheric observations with boundary layer theory, (c) to model upstream impacts of fire and fossilmore » fuel emissions on atmospheric carbon dioxide observations, and (d) to model carbon dioxide observations within urban systems and at the urban-wildland interfaces of forest ecosystems.« less
Protection against fire in the mountainous forests of Greece case study: forest complex of W. Nestos
NASA Astrophysics Data System (ADS)
Drosos, Vasileios C.; Giannoulas, Vasileios J.; Stergiadou, Anastasia; Karagiannis, Evaggelos; Doukas, Aristotelis-Kosmas G.
2014-08-01
Forest fires are an ancient phenomenon. Appear, however, with devastating frequency and intensity over the last 30 years. In our country, the climatic conditions in combination with the intense relief, favor their rapid spread. Considering the fact that environmental conditions provided for decades even worse (increased temperature, drought and vegetation), then the problem of forest fires in our country, is expected to become more intense. The work focuses on the optimization model of the opening up of the forest mountain areas taking into account the prevention and suppression of forest fires. Research area is the mountain forest complex of W. Nestos of Drama Prefecture. The percentage of forest protection area is examined under the light whether the total hose length corresponds to the actual operational capacity to reach a fire source. For this reason are decided to present a three case study concerning area of the forest being protected by fire extinguishing vehicles. The first one corresponds to a fire suppression bandwidth (buffer zone) with a capacity radius of 150m uphill and 250m downhill from the origin point where the fire extinguishing vehicle stands. The second one corresponds to a fire suppression capacity of 200m uphill and 400m downhill and the third one corresponds to a fire suppression capacity of 300m uphill and 500m downhill. The most important forest technical infrastructures to prevent fire are roads network (opening up) for fire protection and buffer zones. Patrols of small and agile 4 × 4 appropriately equipped (pipe length of 500 meters and putting pressure on uphill to 300 meters) for the first attack of the fire in the summer months coupled with early warning of fire observatories adequately cover the forest protection of W. Nestos complex. But spatial distribution needed improvements to a road density of the optimum economic Dec, both forest protection and for better management (skidding) of woody capital.
Parthum, Bryan M.; Pindilli, Emily J.; Hogan, Dianna
2017-01-01
The Great Dismal Swamp (GDS) National Wildlife Refuge delivers multiple ecosystem services, including air quality and human health via fire mitigation. Our analysis estimates benefits of this service through its potential to reduce catastrophic wildfire related impacts on the health of nearby human populations. We used a combination of high-frequency satellite data, ground sensors, and air quality indices to determine periods of public exposure to dense emissions from a wildfire within the GDS. We examined emergency department (ED) visitation in seven Virginia counties during these periods, applied measures of cumulative Relative Risk to derive the effects of wildfire smoke exposure on ED visitation rates, and estimated economic losses using regional Cost of Illness values established within the US Environmental Protection Agency BenMAP framework. Our results estimated the value of one avoided catastrophic wildfire in the refuge to be \\$3.69 million (2015 USD), or \\$306 per hectare of burn. Reducing the frequency or severity of extensive, deep burning peatland wildfire events has additional benefits not included in this estimate, including avoided costs related to fire suppression during a burn, carbon dioxide emissions, impacts to wildlife, and negative outcomes associated with recreation and regional tourism. We suggest the societal value of the public health benefits alone provides a significant incentive for refuge mangers to implement strategies that will reduce the severity of catastrophic wildfires.
Parthum, Bryan; Pindilli, Emily; Hogan, Dianna
2017-12-01
The Great Dismal Swamp (GDS) National Wildlife Refuge delivers multiple ecosystem services, including air quality and human health via fire mitigation. Our analysis estimates benefits of this service through its potential to reduce catastrophic wildfire related impacts on the health of nearby human populations. We used a combination of high-frequency satellite data, ground sensors, and air quality indices to determine periods of public exposure to dense emissions from a wildfire within the GDS. We examined emergency department (ED) visitation in seven Virginia counties during these periods, applied measures of cumulative Relative Risk to derive the effects of wildfire smoke exposure on ED visitation rates, and estimated economic losses using regional Cost of Illness values established within the US Environmental Protection Agency BenMAP framework. Our results estimated the value of one avoided catastrophic wildfire in the refuge to be $3.69 million (2015 USD), or $306 per hectare of burn. Reducing the frequency or severity of extensive, deep burning peatland wildfire events has additional benefits not included in this estimate, including avoided costs related to fire suppression during a burn, carbon dioxide emissions, impacts to wildlife, and negative outcomes associated with recreation and regional tourism. We suggest the societal value of the public health benefits alone provides a significant incentive for refuge mangers to implement strategies that will reduce the severity of catastrophic wildfires. Published by Elsevier Ltd.
Rose, Eli T.; Simons, Theodore R.
2016-01-01
Fire suppression in southern Appalachian pine–oak forests during the past century dramatically altered the bird community. Fire return intervals decreased, resulting in local extirpation or population declines of many bird species adapted to post-fire plant communities. Within Great Smoky Mountains National Park, declines have been strongest for birds inhabiting xeric pine–oak forests that depend on frequent fire. The buildup of fuels after decades of fire suppression led to changes in the 1996 Great Smoky Mountains Fire Management Plan. Although fire return intervals remain well below historic levels, management changes have helped increase the amount of fire within the park over the past 20 years, providing an opportunity to study patterns of fire severity, time since burn, and bird occurrence. We combined avian point counts in burned and unburned areas with remote sensing indices of fire severity to infer temporal changes in bird occurrence for up to 28 years following fire. Using hierarchical linear models that account for the possibility of a species presence at a site when no individuals are detected, we developed occurrence models for 24 species: 13 occurred more frequently in burned areas, 2 occurred less frequently, and 9 showed no significant difference between burned and unburned areas. Within burned areas, the top models for each species included fire severity, time since burn, or both, suggesting that fire influenced patterns of species occurrence for all 24 species. Our findings suggest that no single fire management strategy will suit all species. To capture peak occupancy for the entire bird community within xeric pine–oak forests, at least 3 fire regimes may be necessary; one applying frequent low severity fire, another using infrequent low severity fire, and a third using infrequently applied high severity fire.
Probability model for analyzing fire management alternatives: theory and structure
Frederick W. Bratten
1982-01-01
A theoretical probability model has been developed for analyzing program alternatives in fire management. It includes submodels or modules for predicting probabilities of fire behavior, fire occurrence, fire suppression, effects of fire on land resources, and financial effects of fire. Generalized "fire management situations" are used to represent actual fire...
Haiganoush Preisler; Alan Ager
2013-01-01
For applied mathematicians forest fire models refer mainly to a non-linear dynamic system often used to simulate spread of fire. For forest managers forest fire models may pertain to any of the three phases of fire management: prefire planning (fire risk models), fire suppression (fire behavior models), and postfire evaluation (fire effects and economic models). In...
The biodiversity cost of carbon sequestration in tropical savanna.
Abreu, Rodolfo C R; Hoffmann, William A; Vasconcelos, Heraldo L; Pilon, Natashi A; Rossatto, Davi R; Durigan, Giselda
2017-08-01
Tropical savannas have been increasingly viewed as an opportunity for carbon sequestration through fire suppression and afforestation, but insufficient attention has been given to the consequences for biodiversity. To evaluate the biodiversity costs of increasing carbon sequestration, we quantified changes in ecosystem carbon stocks and the associated changes in communities of plants and ants resulting from fire suppression in savannas of the Brazilian Cerrado, a global biodiversity hotspot. Fire suppression resulted in increased carbon stocks of 1.2 Mg ha -1 year -1 since 1986 but was associated with acute species loss. In sites fully encroached by forest, plant species richness declined by 27%, and ant richness declined by 35%. Richness of savanna specialists, the species most at risk of local extinction due to forest encroachment, declined by 67% for plants and 86% for ants. This loss highlights the important role of fire in maintaining biodiversity in tropical savannas, a role that is not reflected in current policies of fire suppression throughout the Brazilian Cerrado. In tropical grasslands and savannas throughout the tropics, carbon mitigation programs that promote forest cover cannot be assumed to provide net benefits for conservation.
Joe H. Scott; Donald J. Helmbrecht; Sean A. Parks; Carol Miller
2012-01-01
An important objective for many federal land management agencies is to restore fire to ecosystems that have experienced fire suppression or exclusion over the last century. Managing wildfires for resource objectives (i.e., allowing wildfires to burn in the absence of suppression) is an important tool for restoring such fire-adapted ecosystems. To support management...
Public webinar: Wildland Fire Sensors Challenge
This multi-agency challenge seeks a field-ready prototype system capable of measuring constituents of smoke, including particulates, carbon monoxide, ozone, and carbon dioxide, over the wide range of levels expected during wildland fires. The prototype system should be accurate, ...
NASA Astrophysics Data System (ADS)
Li, F.; Lawrence, D. M.; Bond-Lamberty, B. P.
2017-12-01
Fire is a fundamental Earth system process and the primary ecosystem disturbance on the global scale. It affects carbon and water cycles through its impact on terrestrial ecosystems, and at the same time, is regulated by weather and climate, vegetation characteristics, and, importantly, human ignition and efforts to suppress fires (i.e., the direct human effect on fire). Here, we utilize the Community Land Model version 4.5 (CLM4.5) to generate a quantitative understanding of the impacts on fire dynamics and associated carbon and water cycling that can be attributed to changes in human ignition and suppression over the 20th century. We find that the net impact of increases in human ignition and suppression significantly reduce the 20th century averaged global burned area by 38 Mha/yr. The reduction increases since 1920, rising to 103 Mha/yr less burned area at the end of the century. Land carbon gain is weakened by 17% over the 20th century, mainly due to increased human deforestation fires and associated escape fires (i.e., degradation fires) in the tropical humid forests, even though the decrease in burned area in many other regions due to human fire suppression acts to increase land carbon gain. The direct human effect on fire also weakens the 20th century upward trend of global runoff by 6%, and enhances the upward trend in global evaportranspiration since 1945 by 7%. In addition, the above impacts in densely populated, highly developed (if population density > 0.1 person/km2), or moderately populated and developed regions are of opposite sign to those in other regions. Our study suggests that particular attention should be paid to human deforestation and degradation fires in the tropical humid forests when reconstructing and projecting fire carbon emissions and net atmosphere-land carbon exchange and estimating resultant impacts of direct human effect on fire.
This guidance document focuses on several fugitive emissions sources that are common for organizations in many sectors: refrigeration and air conditioningsystems, fire suppression systems, and the purchase and release of industrial gases.
Gaikowski, Mark P.; Hamilton, Steven J.; Buhl, Kevin J.; McDonald, Susan F.; Summers, Cliff H.; Linder, G.; Krest, S.; Sparling, D.; Little, E.
1996-01-01
Laboratory studies were conducted with five early life stages of rainbow trout, Oncorhynchus mykiss, to determine the acute toxicities of five fire-fighting chemical formulations in standardized soft and hard water. Eyed egg, embryo–larvae, swim-up fry, and 60- and 90-d posthatch juveniles were exposed to three fire retardants (Fire-Trol LCG-R, Fire-Trol GTS-R, and Phos-Chek D75-F) and two fire-suppressant foams (Phos-Chek WD-881 and Silv-Ex). Swim-up fry were generally the most sensitive life stage, whereas the eyed-egg was the least sensitive. Toxicity of fire-fighting formulations was greater in hard water than in soft water for all life stages tested with Fire-Trol GTS-R and Silv-Ex and for 90-d-old juveniles tested with Fire-Trol LCG-R. The fire-suppressant foams were more toxic than the fire retardants. The 96-h median lethal concentrations (LC50s) were ranked from the most toxic to the least toxic formulation as follows (ranges are the lowest and highest 96-h LC50 calculated for each formulation): Phos-Chek WD-881 (11–44 mg/L), Silv-Ex (11–78 mg/L), Phos-Chek D75-F (218–>3,600 mg/L), Fire-Trol GTS-R (207–>6,000 mg/L), and Fire-Trol LCG-R (872–>10,000 mg/L). Toxicity values suggest that accidental entry of fire-fighting chemicals into aquatic environments could adversely affect fish populations.
White, Joseph D.; Gutzwiller, Kevin J.; Barrow, Wylie C.; Johnson-Randall, Lori; Zygo, Lisa; Swint, Pamela
2011-01-01
Avian conservation efforts must account for changes in vegetation composition and structure associated with climate change. We modeled vegetation change and the probability of occurrence of birds to project changes in winter bird distributions associated with climate change and fire management in the northern Chihuahuan Desert (southwestern U.S.A.). We simulated vegetation change in a process-based model (Landscape and Fire Simulator) in which anticipated climate change was associated with doubling of current atmospheric carbon dioxide over the next 50 years. We estimated the relative probability of bird occurrence on the basis of statistical models derived from field observations of birds and data on vegetation type, topography, and roads. We selected 3 focal species, Scaled Quail (Callipepla squamata), Loggerhead Shrike (Lanius ludovicianus), and Rock Wren (Salpinctes obsoletus), that had a range of probabilities of occurrence for our study area. Our simulations projected increases in relative probability of bird occurrence in shrubland and decreases in grassland and Yucca spp. and ocotillo (Fouquieria splendens) vegetation. Generally, the relative probability of occurrence of all 3 species was highest in shrubland because leaf-area index values were lower in shrubland. This high probability of occurrence likely is related to the species' use of open vegetation for foraging. Fire suppression had little effect on projected vegetation composition because as climate changed there was less fuel and burned area. Our results show that if future water limits on plant type are considered, models that incorporate spatial data may suggest how and where different species of birds may respond to vegetation changes.
White, Joseph D.; Gutzwiller, Kevin J.; Barrow, Wylie C.; Johnson-Randall, Lori; Zygo, Lisa; Swint, Pamela
2011-01-01
Avian conservation efforts must account for changes in vegetation composition and structure associated with climate change. We modeled vegetation change and the probability of occurrence of birds to project changes in winter bird distributions associated with climate change and fire management in the northern Chihuahuan Desert (southwestern U.S.A.). We simulated vegetation change in a process-based model (Landscape and Fire Simulator) in which anticipated climate change was associated with doubling of current atmospheric carbon dioxide over the next 50 years. We estimated the relative probability of bird occurrence on the basis of statistical models derived from field observations of birds and data on vegetation type, topography, and roads. We selected 3 focal species, Scaled Quail (Callipepla squamata), Loggerhead Shrike (Lanius ludovicianus), and Rock Wren (Salpinctes obsoletus), that had a range of probabilities of occurrence for our study area. Our simulations projected increases in relative probability of bird occurrence in shrubland and decreases in grassland and Yucca spp. and ocotillo (Fouquieria splendens) vegetation. Generally, the relative probability of occurrence of all 3 species was highest in shrubland because leaf-area index values were lower in shrubland. This high probability of occurrence likely is related to the species' use of open vegetation for foraging. Fire suppression had little effect on projected vegetation composition because as climate changed there was less fuel and burned area. Our results show that if future water limits on plant type are considered, models that incorporate spatial data may suggest how and where different species of birds may respond to vegetation changes. ??2011 Society for Conservation Biology.
NASA Astrophysics Data System (ADS)
Zhang, Bin; Jiang, Yujie; Han, Jian
2017-12-01
The core-double-shell microcapsules flame retardant has been regarded as a promising additive for improving the fire safety of PVC. In this article, melamine-formaldehyde resin (MF)/silicon dioxide (SiO2)/zinc hydroxystannate (ZHS) microcapsule was prepared. The effect of synthetic parameters (such as pH, agitation speed, reaction time and reaction temperature) on the morphologies and sizes of the SiO2/ZHS microcapsules were investigated in details. MF/SiO2/ZHS microcapsule was introduced into PVC to prepare biofunctional composites with excellent fire resistance and smoke suppression. The flammability of PVC composites was characterized by limiting oxygen index (LOI), smoke density (SDR), cone calorimeter test. The results showed that the sample containing 16.4% MF/SiO2/ZHS microcapsule (the mass ratio of MF:SiO2:ZHS = 2.5:2:8) achieved the maximal LOI value of 35.6%, minimal SDR value of 21.2%, and significantly decreased the peak heat release rate from 179.7 kW/m2 of neat PVC to 108.3 kW/m2. The thermal behaviors of PVC composites and the morphologies of residues were characterized.
David Calkin; Kevin Hyde; Krista Gebert; Greg Jones
2005-01-01
Determining the economic effectiveness of wildfire suppression activities is complicated by difficulties in identifying the area that would have burned and the associated resource value changes had suppression resources not been employed. We developed a case study using break-even analysis for two large wildfires from the 2003 fire season in western Montana -- the...
46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
....30-10(C): Table 25.30-10(C) Classification Foam, liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...
46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.
Code of Federal Regulations, 2012 CFR
2012-10-01
....30-10(C): Table 25.30-10(c) Classification Foam, liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...
46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
....30-10(C): Table 25.30-10(c) Classification Foam, liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...
46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.
Code of Federal Regulations, 2014 CFR
2014-10-01
....30-10(C): Table 25.30-10(c) Classification Foam,liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...
46 CFR 25.30-10 - Hand-portable fire extinguishers and semi-portable fire-extinguishing systems.
Code of Federal Regulations, 2013 CFR
2013-10-01
....30-10(C): Table 25.30-10(c) Classification Foam,liters (gallons) Carbon dioxide, kilograms (pounds... tampering or use when broken) are not intact, the boarding officer or marine inspector will inspect such...
30 CFR 57.4761 - Underground shops.
Code of Federal Regulations, 2011 CFR
2011-07-01
... an automatic fire suppression system in conjunction with an alternate escape route. The alternative... core, are acceptable provided that an automatic sprinkler or deluge system is installed that provides... conditions and procedures. (d) Automatic fire suppression system and escape route. If used as an alternative...
30 CFR 57.4761 - Underground shops.
Code of Federal Regulations, 2013 CFR
2013-07-01
... an automatic fire suppression system in conjunction with an alternate escape route. The alternative... core, are acceptable provided that an automatic sprinkler or deluge system is installed that provides... conditions and procedures. (d) Automatic fire suppression system and escape route. If used as an alternative...
30 CFR 57.4761 - Underground shops.
Code of Federal Regulations, 2014 CFR
2014-07-01
... an automatic fire suppression system in conjunction with an alternate escape route. The alternative... core, are acceptable provided that an automatic sprinkler or deluge system is installed that provides... conditions and procedures. (d) Automatic fire suppression system and escape route. If used as an alternative...
30 CFR 57.4761 - Underground shops.
Code of Federal Regulations, 2012 CFR
2012-07-01
... an automatic fire suppression system in conjunction with an alternate escape route. The alternative... core, are acceptable provided that an automatic sprinkler or deluge system is installed that provides... conditions and procedures. (d) Automatic fire suppression system and escape route. If used as an alternative...
Jamie M. Lydersen; Malcolm P. North; Eric E. Knapp; Brandon M. Collins
2013-01-01
Fire suppression and past logging have dramatically altered forest conditions in many areas, but changes to within-stand tree spatial patterns over time are not as well understood. The few studies available suggest that variability in tree spatial patterns is an important structural feature of forests with intact frequent fire regimes that should be incorporated in...
Seasonal changes in the human alteration of fire regimes beyond the climate forcing
NASA Astrophysics Data System (ADS)
Fréjaville, Thibaut; Curt, Thomas
2017-03-01
Human activities have altered fire regimes for millennia by suppressing or enhancing natural fire activity. However, whether these anthropogenic pressures on fire activity have exceeded and will surpass climate forcing still remains uncertain. We tested if, how and the extent to which seasonal fire activity in southern France has recently (1976-2009) deviated from climate-expected trends. The latter were simulated using an ensemble of detrended fire-climate models. We found both seasonal and regional contrasts in climatic effects through a mixture of drought-driven and fuel-limited fire regimes. Dry contemporary conditions chiefly drove fire frequency and burned area, although higher fire activity was related to wetter conditions in the last three years. Surprisingly, the relative importance of preceding wet conditions was higher in winter than in summer, illustrating the strong potential dependency of regional fire-climate relationships on the human use and control of fires. In the Mediterranean mountains, warm winters and springs favour extensive fires in the following dry summer. These results highlight that increasing dryness with climate change could have antagonistic effects on fire regime by leading to larger fires in summer (moisture-limited), but lower fire activity in winter (fuel-limited fire regime). Furthermore, fire trends have significantly diverged from climatic expectations, with a strong negative alteration in fire activity in the Mediterranean lowlands and the summer burned area in the mountains. In contrast, alteration of winter fire frequency in the Mediterranean and Temperate mountains has shifted from positive to negative (or null) trends during the mid-1990s, a period when fire suppression policy underwent major revisions. Our findings demonstrate that changes in land-use and fire suppression policy have probably exceeded the strength of climate change effects on changing fire regime in southern Europe, making regional predictions of future fires highly challenging.
46 CFR 76.15-50 - Lockout valves.
Code of Federal Regulations, 2013 CFR
2013-10-01
... any carbon dioxide extinguishing system protecting a space over 6,000 cubic feet in volume and... system from the protected space or spaces, making it impossible for carbon dioxide to discharge in the... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon...
46 CFR 76.15-50 - Lockout valves.
Code of Federal Regulations, 2014 CFR
2014-10-01
... any carbon dioxide extinguishing system protecting a space over 6,000 cubic feet in volume and... system from the protected space or spaces, making it impossible for carbon dioxide to discharge in the... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon...
Tara Strand; Brian Gullett; Shawn Urbanski; Susan O’Neill; Brian Potter; Johanna Aurell; Amara Holder; Narasimhan Larkin; Mark Moore; Miriam Rorig
2016-01-01
Smoke measurements were made during grass and forest understorey prescribed fires as part of a comprehensive programme to understand fire and smoke behaviour. Instruments deployed on the ground, airplane and tethered aerostat platforms characterised the smoke plumes through measurements of carbon dioxide (CO2), carbon monoxide (CO), methane (CH4) and...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-04-13
... dioxide (CO 2 ) for new affected fossil fuel-fired electric utility generating units (EGUs). The EPA is proposing these requirements because CO 2 is a greenhouse gas (GHG) and fossil fuel-fired power plants are... new fossil fuel-fired EGUs greater than 25 megawatt electric (MWe) to meet an output-based standard of...
Keeley, Jon E; Zedler, Paul H
2009-01-01
We evaluate the fine-grain age patch model of fire regimes in southern California shrublands. Proponents contend that the historical condition was characterized by frequent small to moderate size, slow-moving smoldering fires, and that this regime has been disrupted by fire suppression activities that have caused unnatural fuel accumulation and anomalously large and catastrophic wildfires. A review of more than 100 19th-century newspaper reports reveals that large, high-intensity wildfires predate modern fire suppression policy, and extensive newspaper coverage plus first-hand accounts support the conclusion that the 1889 Santiago Canyon Fire was the largest fire in California history. Proponents of the fine-grain age patch model contend that even the very earliest 20th-century fires were the result of fire suppression disrupting natural fuel structure. We tested that hypothesis and found that, within the fire perimeters of two of the largest early fire events in 1919 and 1932, prior fire suppression activities were insufficient to have altered the natural fuel structure. Over the last 130 years there has been no significant change in the incidence of large fires greater than 10,000 ha, consistent with the conclusion that fire suppression activities are not the cause of these fire events. Eight megafires (> or = 50,000 ha) are recorded for the region, and half have occurred in the last five years. These burned through a mosaic of age classes, which raises doubts that accumulation of old age classes explains these events. Extreme drought is a plausible explanation for this recent rash of such events, and it is hypothesized that these are due to droughts that led to increased dead fine fuels that promoted the incidence of firebrands and spot fires. A major shortcoming of the fine-grain age patch model is that it requires age-dependent flammability of shrubland fuels, but seral stage chaparral is dominated by short-lived species that create a dense surface layer of fine fuels. Results from the Behave Plus fire model with a custom fuel module for young chaparral shows that there is sufficient dead fuel to spread fire even under relatively little winds. Empirical studies of fuel ages burned in recent fires illustrate that young fuels often comprise a major portion of burned vegetation, and there is no difference between evergreen chaparral and semi-deciduous sage scrub. It has also been argued that the present-day fire size distribution in northern Baja California is a model of the historical patterns that were present on southern California landscapes. Applying this model with historical fire frequencies shows that the Baja model is inadequate to maintain these fire-prone ecosystems and further demonstrates that fire managers in southern California are not likely to learn much from studying modern Baja California fire regimes. Further supporting this conclusion are theoretical cellular automata models of fire spread, which show that, even in systems with age dependent flammability, landscapes evolve toward a complex age mosaic with a plausible age structure only when there is a severe stopping rule that constrains fire size, and only if ignitions are saturating.
Keeley, J.E.; Zedler, P.H.
2009-01-01
We evaluate the fine-grain age patch model of fire regimes in southern California shrublands. Proponents contend that the historical condition was characterized by frequent small to moderate size, slow-moving smoldering fires, and that this regime has been disrupted by fire suppression activities that have caused unnatural fuel accumulation and anomalously large and catastrophic wildfires. A review of more than 100 19th-century newspaper reports reveals that large, high-intensity wildfires predate modern fire suppression policy, and extensive newspaper coverage plus first-hand accounts support the conclusion that the 1889 Santiago Canyon Fire was the largest fire in California history. Proponents of the fine-grain age patch model contend that even the very earliest 20th-century fires were the result of fire suppression disrupting natural fuel structure. We tested that hypothesis and found that, within the fire perimeters of two of the largest early fire events in 1919 and 1932, prior fire suppression activities were insufficient to have altered the natural fuel structure. Over the last 130 years there has been no significant change in the incidence of large fires greater than 10000 ha, consistent with the conclusion that fire suppression activities are not the cause of these fire events. Eight megafires (???50 000 ha) are recorded for the region, and half have occurred in the last five years. These burned through a mosaic of age classes, which raises doubts that accumulation of old age classes explains these events. Extreme drought is a plausible explanation for this recent rash of such events, and it is hypothesized that these are due to droughts that led to increased dead fine fuels that promoted the incidence of firebrands and spot fires. A major shortcoming of the fine-grain age patch model is that it requires age-dependent flammability of shrubland fuels, but seral stage chaparral is dominated by short-lived species that create a dense surface layer of fine fuels. Results from the Behave Plus fire model with a custom fuel module for young chaparral shows that there is sufficient dead fuel to spread fire even under relatively little winds. Empirical studies of fuel ages burned in recent fires illustrate that young fuels often comprise a major portion of burned vegetation, and there is no difference between evergreen chaparral and semi-deciduous sage scrub. It has also been argued that the present-day fire size distribution in northern Baja California is a model of the historical patterns that were present on southern California landscapes. Applying this model with historical fire frequencies shows that the Baja model is inadequate to maintain these fire-prone ecosystems and further demonstrates that fire managers in southern California are not likely to learn much from studying modern Baja California fire regimes. Further supporting this conclusion are theoretical cellular automata models of fire spread, which show that, even in systems with age dependent flammability, landscapes evolve toward a complex age mosaic with a plausible age structure only when there is a severe stopping rule that constrains fire size, and only if ignitions are saturating. ?? 2009 by the Ecological Society of America.
Chris A. Childers; Douglas D. Piirto
1989-01-01
Fire management has always meant fire suppression to the managers of the chaparral covered southern California National Forests. Today, Forest Service fire management programs must be cost effective, while wilderness fire management objectives are aimed at recreating natural fire regimes. A cost-effectiveness analysis has been developed to compare fire management...
46 CFR 193.05-10 - Fixed fire extinguishing systems.
Code of Federal Regulations, 2010 CFR
2010-10-01
....05-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH... provided for internal combustion engine installations in accordance with the following: (1) Enclosed spaces containing gasoline engines shall have fixed carbon dioxide systems. (2) If a fire extinguishing system is...
46 CFR 193.05-10 - Fixed fire extinguishing systems.
Code of Federal Regulations, 2011 CFR
2011-10-01
....05-10 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH... provided for internal combustion engine installations in accordance with the following: (1) Enclosed spaces containing gasoline engines shall have fixed carbon dioxide systems. (2) If a fire extinguishing system is...
Code of Federal Regulations, 2013 CFR
2013-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Automatic Sprinkling Systems § 108.430 General. Automatic Sprinkler Systems shall comply with NFPA 13-1996. [CGD 95-028, 62 FR 51208, Sept. 30, 1997] Fixed Carbon Dioxide Fire Extinguishing...
Code of Federal Regulations, 2012 CFR
2012-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Automatic Sprinkling Systems § 108.430 General. Automatic Sprinkler Systems shall comply with NFPA 13-1996. [CGD 95-028, 62 FR 51208, Sept. 30, 1997] Fixed Carbon Dioxide Fire Extinguishing...
Code of Federal Regulations, 2011 CFR
2011-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Automatic Sprinkling Systems § 108.430 General. Automatic Sprinkler Systems shall comply with NFPA 13-1996. [CGD 95-028, 62 FR 51208, Sept. 30, 1997] Fixed Carbon Dioxide Fire Extinguishing...
Code of Federal Regulations, 2014 CFR
2014-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Automatic Sprinkling Systems § 108.430 General. Automatic Sprinkler Systems shall comply with NFPA 13-1996. [CGD 95-028, 62 FR 51208, Sept. 30, 1997] Fixed Carbon Dioxide Fire Extinguishing...
Code of Federal Regulations, 2010 CFR
2010-10-01
..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Automatic Sprinkling Systems § 108.430 General. Automatic Sprinkler Systems shall comply with NFPA 13-1996. [CGD 95-028, 62 FR 51208, Sept. 30, 1997] Fixed Carbon Dioxide Fire Extinguishing...
LaWen Hollingsworth; James Menakis
2010-01-01
This project mapped wildland fire potential (WFP) for the conterminous United States by using the large fire simulation system developed for Fire Program Analysis (FPA) System. The large fire simulation system, referred to here as LFSim, consists of modules for weather generation, fire occurrence, fire suppression, and fire growth modeling. Weather was generated with...
44 CFR 204.3 - Definitions used throughout this part.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Worksheet. Fire complex. Two or more individual fires located in the same general area, which are assigned.... The ranking official responsible for overseeing the management of fire operations, planning, logistics... existing fire prevention or suppression resources from an area of lower fire danger to one of higher fire...
44 CFR 204.3 - Definitions used throughout this part.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Worksheet. Fire complex. Two or more individual fires located in the same general area, which are assigned.... The ranking official responsible for overseeing the management of fire operations, planning, logistics... existing fire prevention or suppression resources from an area of lower fire danger to one of higher fire...
44 CFR 204.3 - Definitions used throughout this part.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Worksheet. Fire complex. Two or more individual fires located in the same general area, which are assigned.... The ranking official responsible for overseeing the management of fire operations, planning, logistics... existing fire prevention or suppression resources from an area of lower fire danger to one of higher fire...
Fire protection for a Martian colony
NASA Astrophysics Data System (ADS)
Beattie, Robert M., Jr.
The fire prevention failures that occurred in Apollo 1 and Challenger accidents are reviewed and used to discuss fire protection measures that should be taken in a Martian colony. Fire detection systems, classes of fire, and suppression agents are described. The organization of fire fighting personnel appropriate for Mars is addressed.
Development of a low cost unmanned aircraft system for atmospheric carbon dioxide leak detection
NASA Astrophysics Data System (ADS)
Mitchell, Taylor Austin
Carbon sequestration, the storage of carbon dioxide gas underground, has the potential to reduce global warming by removing a greenhouse gas from the atmosphere. These storage sites, however, must first be monitored to detect if carbon dioxide is leaking back out to the atmosphere. As an alternative to traditional large ground-based sensor networks to monitor CO2 levels for leaks, unmanned aircraft offer the potential to perform in-situ atmospheric leak detection over large areas for a fraction of the cost. This project developed a proof-of-concept sensor system to map relative carbon dioxide levels to detect potential leaks. The sensor system included a Sensair K-30 FR CO2 sensor, GPS, and altimeter connected an Arduino microcontroller which logged data to an onboard SD card. Ground tests were performed to verify and calibrate the system including wind tunnel tests to determine the optimal configuration of the system for the quickest response time (4-8 seconds based upon flowrate). Tests were then conducted over a controlled release of CO 2 in addition to over controlled rangeland fires which released carbon dioxide over a large area as would be expected from a carbon sequestration source. 3D maps of carbon dioxide were developed from the system telemetry that clearly illustrated increased CO2 levels from the fires. These tests demonstrated the system's ability to detect increased carbon dioxide concentrations in the atmosphere.
NASA Astrophysics Data System (ADS)
Jin, Yufang; Goulden, Michael L.; Faivre, Nicolas; Veraverbeke, Sander; Sun, Fengpeng; Hall, Alex; Hand, Michael S.; Hook, Simon; Randerson, James T.
2015-09-01
The area burned by Southern California wildfires has increased in recent decades, with implications for human health, infrastructure, and ecosystem management. Meteorology and fuel structure are universally recognized controllers of wildfire, but their relative importance, and hence the efficacy of abatement and suppression efforts, remains controversial. Southern California’s wildfires can be partitioned by meteorology: fires typically occur either during Santa Ana winds (SA fires) in October through April, or warm and dry periods in June through September (non-SA fires). Previous work has not quantitatively distinguished between these fire regimes when assessing economic impacts or climate change influence. Here we separate five decades of fire perimeters into those coinciding with and without SA winds. The two fire types contributed almost equally to burned area, yet SA fires were responsible for 80% of cumulative 1990-2009 economic losses (3.1 Billion). The damage disparity was driven by fire characteristics: SA fires spread three times faster, occurred closer to urban areas, and burned into areas with greater housing values. Non-SA fires were comparatively more sensitive to age-dependent fuels, often occurred in higher elevation forests, lasted for extended periods, and accounted for 70% of total suppression costs. An improved distinction of fire type has implications for future projections and management. The area burned in non-SA fires is projected to increase 77% (±43%) by the mid-21st century with warmer and drier summers, and the SA area burned is projected to increase 64% (±76%), underscoring the need to evaluate the allocation and effectiveness of suppression investments.
Jang, Jin Young; Jang, Miae; Kim, Shin Hye; Um, Ki Bum; Kang, Yun Kyung; Kim, Hyun Jin; Chung, Sungkwon; Park, Myoung Kyu
2011-03-01
Dopamine (DA) receptors generate many cellular signals and play various roles in locomotion, motivation, hormone production, and drug abuse. According to the location and expression types of the receptors in the brain, DA signals act in either stimulatory or inhibitory manners. Although DA autoreceptors in the substantia nigra pars compacta are known to regulate firing activity, the exact expression patterns and roles of DA autoreceptor types on the firing activity are highly debated. Therefore, we performed individual correlation studies between firing activity and receptor expression patterns using acutely isolated rat substantia nigra pars compacta DA neurons. When we performed single-cell RT-PCR experiments, D(1), D(2)S, D(2)L, D(3), and D(5) receptor mRNA were heterogeneously expressed in the order of D(2)L > D(2)S > D(3) > D(5) > D(1). Stimulation of D(2) receptors with quinpirole suppressed spontaneous firing similarly among all neurons expressing mRNA solely for D(2)S, D(2)L, or D(3) receptors. However, quinpirole most strongly suppressed spontaneous firing in the neurons expressing mRNA for both D(2) and D(3) receptors. These data suggest that D(2) S, D(2)L, and D(3) receptors are able to equally suppress firing activity, but that D(2) and D(3) receptors synergistically suppress firing. This diversity in DA autoreceptors could explain the various actions of DA in the brain. © 2011 The Authors. Journal of Neurochemistry © 2011 International Society for Neurochemistry.
Manual fire suppression methods on typical machinery space spray fires
NASA Astrophysics Data System (ADS)
Carhart, H. W.; Leonard, J. T.; Budnick, E. K.; Ouellette, R. J.; Shanley, J. H., Jr.
1990-07-01
A series of tests was conducted to evaluate the effectiveness of Aqueous Film Forming Foam (AFFF), potassium bicarbonate powder (PKP) and Halon 1211, alone and in various combinations, in extinguishing spray fires. The sprays were generated by JP-5 jet fuel issuing from an open sounding tube, and open petcock, a leaking flange or a slit pipe, and contacting an ignition source. The results indicate that typical fuel spray fires, such as those simulated in this series, are very severe. Flame heights ranged from 6.1 m (20 ft) for the split pipe to 15.2 m (50 ft) for the sounding tube scenario. These large flame geometries were accompanied by heat release rates of 6 MW to greater than 50 MW, and hazardous thermal radiation levels in the near field environment, up to 9.1 m (30 ft) away. Successful suppression of these fires requires both a significant reduction in flame radiation and delivery of a suppression agent to shielded areas. Of the nine suppression methods tested, the 95 gpm AFFF hand line and the hand line in conjunction with PKP were particularly effective in reducing the radiant flux.
The biodiversity cost of carbon sequestration in tropical savanna
Abreu, Rodolfo C. R.; Hoffmann, William A.; Vasconcelos, Heraldo L.; Pilon, Natashi A.; Rossatto, Davi R.; Durigan, Giselda
2017-01-01
Tropical savannas have been increasingly viewed as an opportunity for carbon sequestration through fire suppression and afforestation, but insufficient attention has been given to the consequences for biodiversity. To evaluate the biodiversity costs of increasing carbon sequestration, we quantified changes in ecosystem carbon stocks and the associated changes in communities of plants and ants resulting from fire suppression in savannas of the Brazilian Cerrado, a global biodiversity hotspot. Fire suppression resulted in increased carbon stocks of 1.2 Mg ha−1 year−1 since 1986 but was associated with acute species loss. In sites fully encroached by forest, plant species richness declined by 27%, and ant richness declined by 35%. Richness of savanna specialists, the species most at risk of local extinction due to forest encroachment, declined by 67% for plants and 86% for ants. This loss highlights the important role of fire in maintaining biodiversity in tropical savannas, a role that is not reflected in current policies of fire suppression throughout the Brazilian Cerrado. In tropical grasslands and savannas throughout the tropics, carbon mitigation programs that promote forest cover cannot be assumed to provide net benefits for conservation. PMID:28875172
Code of Federal Regulations, 2012 CFR
2012-10-01
... automatically and audibly for at least 20 seconds before carbon dioxide is discharged into the space; (2) Be..., DEPARTMENT OF HOMELAND SECURITY (CONTINUED) CARGO AND MISCELLANEOUS VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide Extinguishing Systems, Details § 95.15-30 Alarms. (a) A protected space must be fitted with an...
Firefighters wear fireproof clothing and self-contained breathing apparatus (SCBA) during rescue and fire suppression activities to protect against acute effects from heat and toxic chemicals. Fire services are also concerned about long-term health outcomes from chemical exposure...
36 CFR 228.110 - Indemnification.
Code of Federal Regulations, 2010 CFR
2010-07-01
... United States for: (a) Injury, loss or damage, including fire suppression costs, which the United States incurs as a result of the operations; and (b) Payments made by the United States in satisfaction of claims, demands or judgments for an injury, loss or damage, including fire suppression costs, which...
NASA Astrophysics Data System (ADS)
Volkov, R. S.; Zhdanova, A. O.; Kuznetsov, G. V.; Strizhak, P. A.
2018-05-01
Experimental investigations on the characteristic time of suppression of the thermal decomposition reaction of typical forest combustible materials (aspen twigs, birch leaves, spruce needles, pine chips, and a mixture of these materials) and the volume of water required for this purpose have been performed for model fire hotbeds of different areas: SFCM = 0.0003-0.007 m2 and SFCM = 0.045-0.245 m2. In the experiments, aerosol water flows with droplets of size 0.01-0.25 mm were used for the spraying of model fire hotbeds, and the density of spraying was 0.02 L/(m2·s). It was established that the characteristics of suppression of a fire by an aerosol water flow are mainly determined by the sizes of the droplets in this flow. Prognostic estimates of changes in the dispersivity of a droplet cloud, formed from large (as large as 0.5 L) "drops" (water agglomerates) thrown down from a height, have been made. It is shown that these changes can influence the conditions and characteristics of suppression of a forest fire. Dependences, allowing one to forecast the characteristics of suppression of the thermal decomposition of forest combustible materials with the use of large water agglomerates thrown down from an aircraft and aerosol clouds formed from these agglomerates in the process of their movement to the earth, are presented.
NASA Astrophysics Data System (ADS)
Volkov, R. S.; Zhdanova, A. O.; Kuznetsov, G. V.; Strizhak, P. A.
2018-03-01
Experimental investigations on the characteristic time of suppression of the thermal decomposition reaction of typical forest combustible materials (aspen twigs, birch leaves, spruce needles, pine chips, and a mixture of these materials) and the volume of water required for this purpose have been performed for model fire hotbeds of different areas: SFCM = 0.0003-0.007 m2 and SFCM = 0.045-0.245 m2. In the experiments, aerosol water flows with droplets of size 0.01-0.25 mm were used for the spraying of model fire hotbeds, and the density of spraying was 0.02 L/(m2·s). It was established that the characteristics of suppression of a fire by an aerosol water flow are mainly determined by the sizes of the droplets in this flow. Prognostic estimates of changes in the dispersivity of a droplet cloud, formed from large (as large as 0.5 L) "drops" (water agglomerates) thrown down from a height, have been made. It is shown that these changes can influence the conditions and characteristics of suppression of a forest fire. Dependences, allowing one to forecast the characteristics of suppression of the thermal decomposition of forest combustible materials with the use of large water agglomerates thrown down from an aircraft and aerosol clouds formed from these agglomerates in the process of their movement to the earth, are presented.
46 CFR 108.455 - Enclosure openings.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Enclosure openings. 108.455 Section 108.455 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.455 Enclosure...
46 CFR 108.453 - Discharge outlets.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Discharge outlets. 108.453 Section 108.453 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.453 Discharge...
46 CFR 108.453 - Discharge outlets.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Discharge outlets. 108.453 Section 108.453 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.453 Discharge...
46 CFR 108.455 - Enclosure openings.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Enclosure openings. 108.455 Section 108.455 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.455 Enclosure...
EPA Research Highlights: Minimizing SO3 Emissions from Coal-Fired Power Plants
There have been substantial reductions in emissions of particulate matter, nitrogen oxides, and sulfur dioxide through the application of control technologies and strategies. The installation of control technologies has added to the complexity of coal-fired boilers and their ope...
Mark A. Finney; Charles W. McHugh; Roberta Bartlette; Kelly Close; Paul Langowski
2003-01-01
This report summarizes the progress of the Hayman Fire, its behavior, and the influence of environmental conditions. Data were obtained from narratives from fire behavior analysts assigned to the fire management teams, discussions with fire management staff, meteorology from local weather stations and Bradshaw and others (2003), photographs, satellite imagery, and...
46 CFR 167.45-40 - Fire-fighting equipment on nautical school ships using oil as fuel.
Code of Federal Regulations, 2011 CFR
2011-10-01
... following type and character: (a) In each boiler room and in each of the machinery spaces of a nautical... approved fire extinguishers of the foam type of not less than 9.5 liters (21/2 gallons) each or 2 or more approved fire extinguishers of the carbon dioxide type of not less than 33 kilograms (15 pounds) each must...
46 CFR 167.45-40 - Fire-fighting equipment on nautical school ships using oil as fuel.
Code of Federal Regulations, 2010 CFR
2010-10-01
... following type and character: (a) In each boiler room and in each of the machinery spaces of a nautical... approved fire extinguishers of the foam type of not less than 9.5 liters (21/2 gallons) each or 2 or more approved fire extinguishers of the carbon dioxide type of not less than 33 kilograms (15 pounds) each must...
Modeling wildfire incident complexity dynamics
Matthew P. Thompson
2013-01-01
Wildfire management in the United States and elsewhere is challenged by substantial uncertainty regarding the location and timing of fire events, the socioeconomic and ecological consequences of these events, and the costs of suppression. Escalating U.S. Forest Service suppression expenditures is of particular concern at a time of fiscal austerity as swelling fire...
75 FR 60667 - Airworthiness Directives; Learjet Inc. Model 45 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-01
.... This proposed AD would require a general visual inspection for damage of wiring (including chafing... result in a short circuit and the loss of systems associated with the wiring (including fire suppression..., which could result in the loss of systems associated with the wiring (including fire suppression...
Allowable Stresses For Use in Dynamic Analysis of PF-4 Fire Suppression System Piping
DOE Office of Scientific and Technical Information (OSTI.GOV)
Menefee, Maia Catherine; Salmon, Michael W.
The purpose of this paper is to present the results of a limited test program performed on samples of fittings removed from the PF-4 fire suppression system and to present recommendations for allowable stresses to be used in subsequent piping analysis.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 3 2013-10-01 2013-10-01 false Piping. 76.15-15 Section 76.15-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide... forth in this paragraph. Only carbon dioxide or other inert gas shall be used for this test. (2) The...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 3 2012-10-01 2012-10-01 false Piping. 76.15-15 Section 76.15-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide... forth in this paragraph. Only carbon dioxide or other inert gas shall be used for this test. (2) The...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 3 2014-10-01 2014-10-01 false Piping. 76.15-15 Section 76.15-15 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) PASSENGER VESSELS FIRE PROTECTION EQUIPMENT Carbon Dioxide... forth in this paragraph. Only carbon dioxide or other inert gas shall be used for this test. (2) The...
46 CFR 193.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Carbon dioxide storage. 193.15-20 Section 193.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE... storage. (a) Except as provided in paragraph (b) of this section, the cylinders shall be located outside...
46 CFR 193.15-20 - Carbon dioxide storage.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Carbon dioxide storage. 193.15-20 Section 193.15-20 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) OCEANOGRAPHIC RESEARCH VESSELS FIRE... storage. (a) Except as provided in paragraph (b) of this section, the cylinders shall be located outside...
Fire extinguishment in oxygen enriched atmospheres
NASA Technical Reports Server (NTRS)
Robertson, A. F.; Rappaport, M. W.
1973-01-01
Current state-of-the-art of fire suppression and extinguishment techniques in oxygen enriched atmosphere is reviewed. Four classes of extinguishment action are considered: cooling, separation of reactants, dilution or removal of fuel, and use of chemically reactive agents. Current practice seems to show preference for very fast acting water spray applications to all interior surfaces of earth-based chambers. In space, reliance has been placed on fire prevention methods through the removal of ignition sources and use of nonflammable materials. Recommendations are made for further work related to fire suppression and extinguishment in oxygen enriched atmospheres, and an extensive bibliography is appended.
ERIC Educational Resources Information Center
Edmunds, Jane
1972-01-01
Reviews attack on fire safety in high rise buildings made by a group of experts representing the iron and steel industry at a recent conference. According to one expert, fire problems are people oriented, which calls for emphasis on fire prevention rather than reliance on fire suppression and for fire pretection to be built into a structure.…
Ecological fire use for ecological fire management: Managing large wildfires by design
Timothy Ingalsbee
2015-01-01
Past fire exclusion policies and fire suppression actions have led to a historic "fire deficit" on public wildlands. These sociocultural actions have led to unprecedented environmental changes that have created conditions conducive to more frequent large-scale wildfires. Politicians, the newsmedia, and agency officials portray large wildland fires as...
G. B. Snider; P. J. Daugherty
2008-01-01
(Please note, this is an abstract only) In 1905, the Bureau of Forestry became the U.S. Forest Service and was given responsibility for protecting newly designated forest reserves. A critical part of its charge was the prevention and control of fires. In 1908 Congress set up a unique system, like an open checkbook, that assured payment for fire suppression as needed....
Fire and birds in maritime Pacific Northwest
Mark H. Huff; Nathaniel E. Seavy; John D. Alexander; C. John Ralph
2005-01-01
Resource managers face the challenge of understanding how numerous factors, including fire and fire suppression, influence habitat composition and animal communities. We summarize information on fire effects on major vegetation types and bird/fire relations within the maritime Pacific Northwest, and pose management related questions and research considerations....
36 CFR 211.5 - Emergency fire suppression assistance.
Code of Federal Regulations, 2011 CFR
2011-07-01
... this subpart these definitions apply: (1) Prescribed fire means a fire burning under a set of specified conditions which will accomplish certain planned resource management objectives. (2) Escaped prescribed fire means a prescribed fire which has either exceeded the prescription or has rekindled after it has been...
36 CFR 211.5 - Emergency fire suppression assistance.
Code of Federal Regulations, 2014 CFR
2014-07-01
... this subpart these definitions apply: (1) Prescribed fire means a fire burning under a set of specified conditions which will accomplish certain planned resource management objectives. (2) Escaped prescribed fire means a prescribed fire which has either exceeded the prescription or has rekindled after it has been...
36 CFR 211.5 - Emergency fire suppression assistance.
Code of Federal Regulations, 2010 CFR
2010-07-01
... this subpart these definitions apply: (1) Prescribed fire means a fire burning under a set of specified conditions which will accomplish certain planned resource management objectives. (2) Escaped prescribed fire means a prescribed fire which has either exceeded the prescription or has rekindled after it has been...
36 CFR 211.5 - Emergency fire suppression assistance.
Code of Federal Regulations, 2012 CFR
2012-07-01
... this subpart these definitions apply: (1) Prescribed fire means a fire burning under a set of specified conditions which will accomplish certain planned resource management objectives. (2) Escaped prescribed fire means a prescribed fire which has either exceeded the prescription or has rekindled after it has been...
36 CFR 211.5 - Emergency fire suppression assistance.
Code of Federal Regulations, 2013 CFR
2013-07-01
... this subpart these definitions apply: (1) Prescribed fire means a fire burning under a set of specified conditions which will accomplish certain planned resource management objectives. (2) Escaped prescribed fire means a prescribed fire which has either exceeded the prescription or has rekindled after it has been...
Training Fires on Indian Reservations in Idaho, Oregon, and Washington
The Federal Air Rules for Reservations (FARR) Open Burning Rule allows Fire Protection Services to request permission from EPA to conduct an outdoor burn by qualified personnel to train firefighters on fire suppression and fire fighting techniques.
The Evolution of Wildland Fire Management Policy in the USA: Successes and Failures
NASA Astrophysics Data System (ADS)
Gonzalez-Caban, A.
2015-12-01
Wildfires have been suppressed over the last 100 years in forest and brush landscapes. For the last three decades, fires occurrence and severity have significantly increased when compared to historical levels causing economic damage and suppression costs never experienced before in the US or globally. As the wildland fire problem evolved so did the public response through a wildland fire management policy guided by the Forest Service and Bureau of Land Management understanding of the problem. Globally it is estimated that more 350 million hectares of wildland burn annually. They oxidize approximately 3-8% of the total terrestrial net primary productivity. The economic and physical relevance of wildland fire management and protection programs is ever growing, particularly considering mounting wildfire costs and losses globally. In the US alone, from 2000 to 2013 more than 37 million hectares of wildland has been affected at a cost of over $21 billion. The increase in siege-like fires can be explained in part by increasing population, particularly in the wildland-urban interface and the accumulation of biomass fuel due to over a century of fire exclusion. Recent developments demonstrate a strong relationship between fire and weather and climate variations. How the wildland fire management policy has evolved through time? The development can be divided in three stages: the formative years between 1905 and 1911; the consolidation years from 1911 through 1968; and the modern era from 1995 to present. Each stage is characterized by a series of significant events that caused changes on how the problem was approached. For example, the establishment of the Forest Service in 1905 and the rash of large wildfires in the western USA set the base for the wildfire suppression of all wildfires in 1911. During the second stage we see the 1935 policy of suppressing all wildfires by 10-am next-day. By 1968 the policy has evolved to include the use of prescribed burning and the elimination of the 10-am next-day policy. In the modern era, by 1995 the wildland fire management policy changed to require the use of economic efficiency analysis in fire suppression actions. The recently passed FLAME Act and establishment of the FS Cohesive Strategy have been in response to increases in the wildland-urban interface problem and climate change challenges.
Flatley, William T; Lafon, Charles W; Grissino-Mayer, Henri D; LaForest, Lisa B
2013-09-01
Fire-maintained ecosystems and associated species are becoming increasingly rare in the southern Appalachian Mountains because of fire suppression policies implemented in the early 20th century. Restoration of these communities through prescribed fire has been hindered by a lack of information on historical fire regimes. To characterize past fire regimes, we collected and absolutely dated the tree rings on cross sections from 242 fire-scarred trees at three different sites in the southern Appalachian Mountains of Tennessee and North Carolina. Our objectives were to (1) characterize the historical frequency of fire in southern Appalachian mixed pine-oak forests, (2) assess the impact of interannual climatic variability on the historical occurrence of fire, and (3) determine whether changes in human culture and land use altered the frequency of fire. Results demonstrate that fires burned frequently at all three sites for at least two centuries prior to the implementation of fire suppression and prevention in the early to mid 20th century. Composite mean fire return intervals were 2-4 yr, and point mean fire return intervals were 9-13 yr. Area-wide fires that burned across multiple stands occurred at 6-13-yr intervals. The majority of fires were recorded during the dormant season. Fire occurrence exhibited little relationship with reconstructed annual drought conditions. Also, fire activity did not change markedly during the transition from Native American to Euro-American settlement or during the period of industrial logging at the start of the 20th century. Fire activity declined significantly, however, during the fire suppression period, with a nearly complete absence of fire during recent decades. The characterization of past fire regimes should provide managers with specific targets for restoration of fire-associated communities in the southern Appalachian Mountains. The fire chronologies reported here are among the longest tree-ring reconstructions of fire history compiled for the eastern United States and support the hypothesis that frequent burning has played a long and important role in the development of forests in the southern Appalachian Mountains.
46 CFR 108.443 - Controls and valves.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Controls and valves. 108.443 Section 108.443 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.443 Controls and...
46 CFR 108.443 - Controls and valves.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Controls and valves. 108.443 Section 108.443 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.443 Controls and...
43 CFR 9212.2 - Fire prevention orders.
Code of Federal Regulations, 2011 CFR
2011-10-01
... MANAGEMENT, DEPARTMENT OF THE INTERIOR TECHNICAL SERVICES (9000) FIRE MANAGEMENT Wildfire Prevention § 9212.2 Fire prevention orders. (a) To prevent wildfire or facilitate its suppression, an authorized officer...
43 CFR 9212.2 - Fire prevention orders.
Code of Federal Regulations, 2013 CFR
2013-10-01
... MANAGEMENT, DEPARTMENT OF THE INTERIOR TECHNICAL SERVICES (9000) FIRE MANAGEMENT Wildfire Prevention § 9212.2 Fire prevention orders. (a) To prevent wildfire or facilitate its suppression, an authorized officer...
43 CFR 9212.2 - Fire prevention orders.
Code of Federal Regulations, 2014 CFR
2014-10-01
... MANAGEMENT, DEPARTMENT OF THE INTERIOR TECHNICAL SERVICES (9000) FIRE MANAGEMENT Wildfire Prevention § 9212.2 Fire prevention orders. (a) To prevent wildfire or facilitate its suppression, an authorized officer...
43 CFR 9212.2 - Fire prevention orders.
Code of Federal Regulations, 2012 CFR
2012-10-01
... MANAGEMENT, DEPARTMENT OF THE INTERIOR TECHNICAL SERVICES (9000) FIRE MANAGEMENT Wildfire Prevention § 9212.2 Fire prevention orders. (a) To prevent wildfire or facilitate its suppression, an authorized officer...
Fire Technology Abstracts, volume 4, issue 1, August, 1981
NASA Astrophysics Data System (ADS)
Holtschlag, L. J.; Kuvshinoff, B. W.; Jernigan, J. B.
This bibliography contains over 400 citations with abstracts addressing various aspects of fire technology. Subjects cover the dynamics of fire, behavior and properties of materials, fire modeling and test burns, fire protection, fire safety, fire service organization, apparatus and equipment, fire prevention, suppression, planning, human behavior, medical problems, codes and standards, hazard identification, safe handling of materials, insurance, economics of loss and prevention, and more.
Andrew T. Hudak; Patrick H. Freeborn; Sarah A. Lewis; Sharon M. Hood; Helen Y. Smith; Colin C. Hardy; Robert J. Kremens; Bret W. Butler; Casey Teske; Robert G. Tissell; Lloyd P. Queen; Bryce L. Nordgren; Benjamin C. Bright; Penelope Morgan; Philip J. Riggan; Lee Macholz; Leigh B. Lentile; James P. Riddering; Edward E. Mathews
2018-01-01
The Cooney Ridge Fire Experiment conducted by fire scientists in 2003 was a burnout operation supported by a fire suppression crew on the active Cooney Ridge wildfire incident. The fire experiment included measurements of pre-fire fuels, active fire behavior, and immediate post-fire effects. Heat flux measurements collected at multiple scales with multiple ground and...
Fire Protection in Educational Occupancies.
ERIC Educational Resources Information Center
Gervais, Romeo P.
2000-01-01
Discusses the origins of school fires and the components of the fire protection code called the Life Safety Code (LSC). Three of the following LSC requirements are described: means of egress; protection from hazards; and fire suppression and alarm systems. Information on who starts fires is highlighted along with preventive measures. (GR)
Relative impact of weather vs. fuels on fire regimes in coastal California
Jon E. Keeley
2008-01-01
Extreme fire weather is of over riding importance in determining fire behavior in coastal chaparral and on these landscapes fire suppression policy has not resulted in fire exclusion. There is regional variation in foehn winds, which are most important in southern California. Under these severe fire weather conditions fuel age does not constrain fire behavior. As a...
Delayed rectifier K channels contribute to contrast adaptation in mammalian retinal ganglion cells
Weick, Michael; Demb, Jonathan B.
2011-01-01
SUMMARY Retinal ganglion cells adapt by reducing their sensitivity during periods of high contrast. Contrast adaptation in the firing response depends on both presynaptic and intrinsic mechanisms. Here, we investigated intrinsic mechanisms for contrast adaptation in OFF Alpha ganglion cells in the in vitro guinea pig retina. Using either visual stimulation or current injection, we show that brief depolarization evoked spiking and suppressed firing during subsequent depolarization. The suppression could be explained by Na channel inactivation, as shown in salamander cells. However, brief hyperpolarization in the physiological range (5–10 mV) also suppressed firing during subsequent depolarization. This suppression was sensitive selectively to blockers of delayed-rectifier K channels (KDR). Somatic membrane patches showed TEA-sensitive KDR currents with activation near −25 mV and removal of inactivation at voltages negative to Vrest. Brief periods of hyperpolarization apparently remove KDR inactivation and thereby increase the channel pool available to suppress excitability during subsequent depolarization. PMID:21745646
Delayed-rectifier K channels contribute to contrast adaptation in mammalian retinal ganglion cells.
Weick, Michael; Demb, Jonathan B
2011-07-14
Retinal ganglion cells adapt by reducing their sensitivity during periods of high contrast. Contrast adaptation in the firing response depends on both presynaptic and intrinsic mechanisms. Here, we investigated intrinsic mechanisms for contrast adaptation in OFF Alpha ganglion cells in the in vitro guinea pig retina. Using either visual stimulation or current injection, we show that brief depolarization evoked spiking and suppressed firing during subsequent depolarization. The suppression could be explained by Na channel inactivation, as shown in salamander cells. However, brief hyperpolarization in the physiological range (5-10 mV) also suppressed firing during subsequent depolarization. This suppression was selectively sensitive to blockers of delayed-rectifier K channels (K(DR)). In somatic membrane patches, we observed tetraethylammonium-sensitive K(DR) currents that activated near -25 mV. Recovery from inactivation occurred at potentials hyperpolarized to V(rest). Brief periods of hyperpolarization apparently remove K(DR) inactivation and thereby increase the channel pool available to suppress excitability during subsequent depolarization. Copyright © 2011 Elsevier Inc. All rights reserved.
30 CFR 75.1103-10 - Fire suppression systems; additional requirements.
Code of Federal Regulations, 2010 CFR
2010-07-01
... requirements. 75.1103-10 Section 75.1103-10 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT... Protection § 75.1103-10 Fire suppression systems; additional requirements. For each conveyor belt flight... per minute, an additional cache of the materials specified in § 75.1103-9(a)(1), (2), and (3) shall be...
Factors affecting fire suppression costs as identified by incident management teams
Janie Canton-Thompson; Brooke Thompson; Krista Gebert; David Calkin; Geoff Donovan; Greg Jones
2006-01-01
This study uses qualitative sociological methodology to discover information and insights about the role of Incident Management Teams in wildland fire suppression costs. We interviewed 48 command and general staff members of Incident Management Teams throughout the United States. Interviewees were asked about team structure, functioning, and decision making as a...
30 CFR 75.1103-10 - Fire suppression systems; additional requirements.
Code of Federal Regulations, 2014 CFR
2014-07-01
... per minute, an additional cache of the materials specified in § 75.1103-9(a)(1), (2), and (3) shall be... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fire suppression systems; additional requirements. 75.1103-10 Section 75.1103-10 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT...
A Review of Water Mist Technology for Fire Suppression
1994-09-30
Smith, D.P., and Ball, D.N. (1993), "New Applications of Aqueous Agents for Fire Suppression," Halen Alternatives Technical Working Conference...Flows," Prog. Energy, Combust. ScL, 14, 1988, pp. 171-194. Dabros, T., and Van de Ven, T.G.M. (1992), "Hydrodynamic Interactions between Two Spheres Near
The demise of fire and "mesophication" of forests in the eastern United States
Gregory J. Nowacki; Marc D. Abrams
2008-01-01
A diverse array of fire-adapted plant communities once covered the eastern United States. European settlement greatly altered fire regimes, often increasing fire occurrence (e.g., in northern hardwoods) or substantially decreasing it (e.g., in tallgrass prairies). Notwithstanding these changes, fire suppression policies, beginning around the 1920s, greatly reduced fire...
Matthew P. Thompson
2015-01-01
The management of wildfire is a dynamic, complex, and fundamentally uncertain enterprise. Fire managers face uncertainties regarding fire weather and subsequent influence on fire behavior, the effects of fire on socioeconomic and ecological resources, and the efficacy of alternative suppression actions on fire outcomes. In these types of difficult decision environments...
Shift in fire-ecosystems and weather changes
Bongani Finiza
2013-01-01
During recent decades too much focus fell on fire suppression and fire engineering methods. Little attention has been given to understanding the shift in the changing fire weather resulting from the global change in weather patterns. Weather change have gradually changed the way vegetation cover respond to fire occurrence and brought about changes in fire behavior and...
MODIS NDVI Response Following Fires in Siberia
NASA Technical Reports Server (NTRS)
Ranson, K. Jon; Sun, G.; Kovacs, K.; Kharuk, V. I.
2003-01-01
The Siberian boreal forest is considered a carbon sink but may become an important source of carbon dioxide if climatic warming predictions are correct. The forest is continually changing through various disturbance mechanisms such as insects, logging, mineral exploitation, and especially fires. Patterns of disturbance and forest recovery processes are important factors regulating carbon flux in this area. NASA's Terra MODIS provides useful information for assessing location of fires and post fire changes in forests. MODIS fire (MOD14), and NDVI (MOD13) products were used to examine fire occurrence and post fire variability in vegetation cover as indicated by NDVI. Results were interpreted for various post fire outcomes, such as decreased NDVI after fire, no change in NDVI after fire and positive NDVI change after fire. The fire frequency data were also evaluated in terms of proximity to population centers, and transportation networks.
PROTOTYPE SCALE TESTING OF LIMB TECHNOLOGY FOR A PULVERIZED-COAL-FIRED BOILER
The report summarizes results of an evaluation of furnace sorbent injection (FSI) to control sulfur dioxide (SO2) emissions from coal-fired utility boilers. (NOTE: FSI of calcium-based sorbents has shown promise as a moderate SO2 removal technology.) The Electric Power Research I...
The report gives results of the full-scale demonstration of Limestone Injection Multistage Burner (LIMB) technology on the coal-fired, 105 MW, Unit 4 boiler at Ohio Edison's Edgewater Station. eveloped as a technology aimed at moderate levels of sulfur dioxide (SO2) and nitrogen ...
40 CFR 73.20 - Phase II early reduction credits.
Code of Federal Regulations, 2013 CFR
2013-07-01
... utility, including generators that are not fossil fuel-fired) that has decreased its total coal-fired... reductions in sulfur dioxide emissions; and (2) A report listing all units in the utility system, each fossil... total electrical generation for calendar years 1980 and 1985 (including all generators, whether fossil...
40 CFR 73.20 - Phase II early reduction credits.
Code of Federal Regulations, 2011 CFR
2011-07-01
... utility, including generators that are not fossil fuel-fired) that has decreased its total coal-fired... reductions in sulfur dioxide emissions; and (2) A report listing all units in the utility system, each fossil... total electrical generation for calendar years 1980 and 1985 (including all generators, whether fossil...
40 CFR 73.20 - Phase II early reduction credits.
Code of Federal Regulations, 2010 CFR
2010-07-01
... utility, including generators that are not fossil fuel-fired) that has decreased its total coal-fired... reductions in sulfur dioxide emissions; and (2) A report listing all units in the utility system, each fossil... total electrical generation for calendar years 1980 and 1985 (including all generators, whether fossil...
40 CFR 73.20 - Phase II early reduction credits.
Code of Federal Regulations, 2014 CFR
2014-07-01
... utility, including generators that are not fossil fuel-fired) that has decreased its total coal-fired... reductions in sulfur dioxide emissions; and (2) A report listing all units in the utility system, each fossil... total electrical generation for calendar years 1980 and 1985 (including all generators, whether fossil...
46 CFR 108.433 - Quantity of CO2: General.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Quantity of CO2: General. 108.433 Section 108.433 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.433...
46 CFR 108.445 - Alarm and means of escape.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false Alarm and means of escape. 108.445 Section 108.445 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.445...
46 CFR 108.433 - Quantity of CO2: General.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Quantity of CO2: General. 108.433 Section 108.433 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.433...
46 CFR 108.433 - Quantity of CO2: General.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false Quantity of CO2: General. 108.433 Section 108.433 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.433...
46 CFR 108.445 - Alarm and means of escape.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false Alarm and means of escape. 108.445 Section 108.445 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.445...
46 CFR 108.449 - Piping tests.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false Piping tests. 108.449 Section 108.449 Shipping COAST... Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.449 Piping tests. (a) Each test prescribed in (b), (c), and (d) of this section must be performed upon completion of the...
Emissions from forest fires near Mexico City.
R.J. Yokelson; S.P. Urbanski; E.L. Atlas; D.E. Toohey; E.C. Alvarado; J.D. Crounse; P.O. Wennberg; M.E. Fisher; C.E. Would; T.L. Campos; K. Adachi; P.T. Buseck; W.M. Hao
2007-01-01
The emissions of NOx (defined as NO (nitric oxide) + NO2 (nitrogen dioxide)) and hydrogen cyanide (HCN), per unit amount of fuel burned from fires in the pine forests that dominate the mountains surrounding Mexico City (MC) are about 2 times higher than normally observed for forest burning. The ammonia (NH3...
46 CFR 108.443 - Controls and valves.
Code of Federal Regulations, 2011 CFR
2011-10-01
... COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.443 Controls and valves. (a) At least one control for operating a CO2 system must be outside the space or spaces that the...
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 4 2011-10-01 2011-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 4 2013-10-01 2013-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 4 2010-10-01 2010-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 4 2014-10-01 2014-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 4 2012-10-01 2012-10-01 false CO2 storage. 108.451 Section 108.451 Shipping COAST GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT Fire Extinguishing Systems Fixed Carbon Dioxide Fire Extinguishing Systems § 108.451 CO2 storage. (a...
14 CFR 25.1439 - Protective breathing equipment.
Code of Federal Regulations, 2014 CFR
2014-01-01
... breathing equipment must be installed for the use of appropriate crewmembers for fighting fires in... dioxide, and other harmful gases while on flight deck duty or while combating fires. (2) The equipment... considered to be of 15-minute duration at the prescribed altitude and minute volume. If a continuous flow...
14 CFR 25.1439 - Protective breathing equipment.
Code of Federal Regulations, 2013 CFR
2013-01-01
... breathing equipment must be installed for the use of appropriate crewmembers for fighting fires in... dioxide, and other harmful gases while on flight deck duty or while combating fires. (2) The equipment... considered to be of 15-minute duration at the prescribed altitude and minute volume. If a continuous flow...
40 CFR 73.20 - Phase II early reduction credits.
Code of Federal Regulations, 2012 CFR
2012-07-01
... utility, including generators that are not fossil fuel-fired) that has decreased its total coal-fired... quality of fuel being burned. (c) Initial certification of eligibility. The designated representative of a... reductions in sulfur dioxide emissions; and (2) A report listing all units in the utility system, each fossil...
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2011 CFR
2011-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2013 CFR
2013-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2012 CFR
2012-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2010 CFR
2010-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
29 CFR 1915.505 - Fire response.
Code of Federal Regulations, 2014 CFR
2014-07-01
... written standard operating procedures for each type of fire response at the employer's facility; (v) The... suppression operations established by written standard operating procedures for each particular type of fire...) OCCUPATIONAL SAFETY AND HEALTH STANDARDS FOR SHIPYARD EMPLOYMENT Fire Protection in Shipyard Employment § 1915...
Recent changes in annual area burned in interior Alaska: The impact of fire management
Calef, M.P.; Varvak, Anna; McGuire, A. David; Chapin, F. S.; Reinhold, K. B.
2015-01-01
The Alaskan boreal forest is characterized by frequent extensive wildfires whose spatial extent has been mapped for the past 70 years. Simple predictions based on this record indicate that area burned will increase as a response to climate warming in Alaska. However, two additional factors have affected the area burned in this time record: the Pacific decadal oscillation (PDO) switched from cool and moist to warm and dry in the late 1970s and the Alaska Fire Service instituted a fire suppression policy in the late 1980s. In this paper a geographic information system (GIS) is used in combination with statistical analyses to reevaluate the changes in area burned through time in Alaska considering both the influence of the PDO and fire management. The authors found that the area burned has increased since the PDO switch and that fire management drastically decreased the area burned in highly suppressed zones. However, the temporal analysis of this study shows that the area burned is increasing more rapidly in suppressed zones than in the unsuppressed zone since the late 1980s. These results indicate that fire policies as well as regional climate patterns are important as large-scale controls on fires over time and across the Alaskan boreal forest.
Ecosystem carbon dioxide fluxes after disturbance in forests of North America
B. D. Amiro; A. G. Barr; J. G. Barr; T. A. Black; R. Bracho; al. et.
2010-01-01
[1] Disturbances are important for renewal of North American forests. Here we summarize more than 180 site years of eddy covariance measurements of carbon dioxide flux made at forest chronosequences in North America. The disturbances included standreplacing fire (Alaska, Arizona, Manitoba, and Saskatchewan) and harvest (British Columbia, Florida, New Brunswick, Oregon...
Alternative Strategies for Control of Sulfur Dioxide Emissions
ERIC Educational Resources Information Center
MacDonald, Bryce I.
1975-01-01
Achievement of air quality goals requires careful consideration of alternative control strategies in view of national concerns with energy and the economy. Three strategies which might be used by coal fired steam electric plants to achieve ambient air quality standards for sulfur dioxide have been compared and the analysis presented. (Author/BT)
46 CFR 34.05-5 - Fire-extinguishing systems-T/ALL.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Officer in Charge, Marine Inspection. (1) Dry cargo compartments. A carbon dioxide or water spray system... subparagraph. (3) Lamp and paint lockers and similar spaces. A carbon dioxide or water spray system must be..., inert gas, foam or water spray system must be installed for the protection of all pumprooms. (5...
46 CFR 34.05-5 - Fire-extinguishing systems-T/ALL.
Code of Federal Regulations, 2010 CFR
2010-10-01
... Officer in Charge, Marine Inspection. (1) Dry cargo compartments. A carbon dioxide or water spray system... subparagraph. (3) Lamp and paint lockers and similar spaces. A carbon dioxide or water spray system must be..., inert gas, foam or water spray system must be installed for the protection of all pumprooms. (5...
Immunomodulatory properties of titanium dioxide nanostructural materials.
Latha, T Sree; Reddy, Madhava C; R Durbaka, Prasad V; Muthukonda, Shankar V; Lomada, Dakshayani
2017-01-01
Although titanium dioxide (TiO 2 ) nanostructural materials have been widely used in Biology and Medicine, very little is known about immunomodulation mechanism of these materials. Objectives of this study are to investigate in vitro immunomodulatory effects of TiO 2 . Immunosuppressant may lower immune responses and are helpful for the treatment of graft versus host diseases and autoimmune disorders. In this study, we used H 2 Ti 3 O 7 titanium dioxide nanotubes (TNT) nanotubes along with commercial TiO 2 nanoparticles (TNP) and TiO 2 fine particles (TFP). We investigated the in vitro immunomodulatory effects of TNP, TNT, and TFP using mixed lymphocyte reaction (MLR). Suppression was studied by 3-(4, 5-dimethylthiazol-2yl)-2, 5-diphenyl tetrazolium bromide (MTT) assay. Cytokine profile was measured by enzyme-linked immunosorbent assay (ELISA). The results from this study illustrated that the TiO 2 nanostructural materials strongly suppressed splenocytes proliferation in MLR. For TNP and TNT, at 50 μg/ml suppression of 20%-25% and 30%-35%, respectively, and for TFP at 100 μg/ml suppression was 25%-30% was observed. Suppression of splenocytes proliferation in the presence of TNP, TNT, and TFP demonstrated that these nanostructural materials probably block T-cell-mediated responses in vitro . Our ELISA results confirmed that significantly lower levels of Th1 type cytokines (interleukin-2, interferon-γ) in the 48 h MLR culture supernatants. Our data suggest that TiO 2 nanostructural materials suppress splenocytes proliferation by suppressing Th1 cytokines.
Assessing the Role and Impact of Geospatial Data for Wildland Fire Management Decisions
NASA Astrophysics Data System (ADS)
Klein, E. A.; Lev, S. M.
2016-12-01
The 2015 Wildland and Fire Science and Technology Task Force Final Report, produced by the National Science and Technology Council, Committee on Environment, Natural Resources, and Sustainability, Subcommittee on Disaster Reduction, highlighted the increasing frequency of large wildfires and the growing demand for science to inform critical resource decisions to manage, mitigate, respond to, and recover from wildland fires. Federal spending on fire suppression from 2005-2015 has more than doubled despite policy changes that prioritize the mitigation of fire risks through the use of fuel treatments, prescribed fire, and management of naturally occurring wildfires to protect life and property. Fire suppression policies over the last century have created forests primed for severe fire, and in the face of a changing climate, the benefits of re-introducing fire into once fire-resilient ecosystems are clear. There are a range of complex factors and regional variation associated with wildland fire risk that complicate our understanding and effective management of this hazard. Data derived from Earth-observing (EO) systems and networks are a crucial input for managers when making decisions about fire suppression and fuel management. EO data can also be used to develop pre- and post-fire metrics that can aid in the evaluating the effectiveness of wildland fire management decisions. A value-tree method for mapping the role of EO systems and networks in delivering societal benefit through key Federal objectives related to wildland fire management will be presented. The value-tree methodology utilizes input from subject matter experts to assess the availability and usability of data and data products and to evaluate the impact of individual EO data inputs for achieving wildland fire management objectives. The results provide a qualitative assessment of the value of the data for the objectives described and identify critical gaps and continuity issues associated with improvements to and continuous delivery of societal benefit.
Buhl, Kevin J.; Hamilton, Steven J.
1998-01-01
Laboratorys studies were conducted to determine the acute toxicity of three fire retardants (Fire-Trol GTS-R, Fire-Trol LCG-R, and Phos-Chek D75-F), and two fire-suppressant foams (Phos-Chek WD-881 and Ansul Silv-Ex) to early life stages of chinook salmon, Oncorhynchus tshawytscha, in hard and soft water. Regardless of water type, swim-up fry and juveniles (60 and 90 d posthatch) exhibited similar sensitivities to each chemical and these life stages were more sensitive than eyed eggs. Foam suppressants were more toxic to each life stage than the fire retardants in both water types. The descending rank order of toxicity for these chemicals tested with swim-up fry and juveniles (range of 96-h median lethal concentrations [LC50s]) was Phos-Chek WD-881 (7–13 mg/L) > Ansul Silv-Ex (11–22 mg/L) > Phos-Chek D75-F (218–305 mg/L) > Fire-Trol GTS-R (218–412 mg/L) > Fire-Trol LCG-R (685–1,195 mg/L). Water type had a minor effect on the toxicity of these chemicals. Comparison of acute toxicity values with recommended application concentrations indicates that accidental inputs of these chemicals into stream environments would require substantial dilution (237- to 1,429-fold) to reach concentrations equivalent to their 96-h LC50s.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Li, Fang; Lawrence, David M.; Bond-Lamberty, Ben
Fire is a fundamental Earth system process and the primary ecosystem disturbance on the global scale. It affects carbon and water cycles through changing terrestrial ecosystems, and at the same time, is regulated by weather and climate, vegetation characteristics, and, importantly, human ignitions and suppression (i.e., the direct human effect on fire). Here, we utilize the Community Land Model version 4.5 (CLM4.5) to quantify the impacts of changes in human ignition and suppression on fire dynamics and associated carbon and water cycles. We find that the impact is to significantly reduce the 20th century global burned area by a centurymore » average of 38 Mha/yr and by 103 Mha/yr at the end of the century. Land carbon gain is weakened by 17% over the 20th century, mainly due to increased human deforestation fires and associated escape fires (i.e., degradation fires) in the tropical humid forests, even though the decrease in burned area in many other regions due to human fire suppression acts to increase land carbon gain. The direct human effect on fire weakens the upward trend in global runoff throughout the century by 6% and enhances the upward trend in global evapotranspiration since ~ 1945 by 7%. In addition, the above impacts in densely populated, highly developed (if population density > 0.1 person/km2), or moderately populated and developed regions are of opposite sign to those in other regions. Our study suggests that particular attention should be paid to human deforestation and degradation fires in the tropical humid forests when reconstructing and projecting fire carbon emissions and net atmosphere-land carbon exchange and estimating resultant impacts of direct human effect on fire.« less
NASA Astrophysics Data System (ADS)
Li, Fang; Lawrence, David M.; Bond-Lamberty, Ben
2018-03-01
Fire is a fundamental Earth system process and the primary ecosystem disturbance on the global scale. It affects carbon and water cycles through changing terrestrial ecosystems, and at the same time, is regulated by weather and climate, vegetation characteristics, and, importantly, human ignitions and suppression (i.e., the direct human effect on fire). Here, we utilize the Community Land Model version 4.5 (CLM4.5) to quantify the impacts of changes in human ignition and suppression on fire dynamics and associated carbon and water cycles. We find that the impact is to significantly reduce the 20th century global burned area by a century average of 38 Mha/yr and by 103 Mha/yr at the end of the century. Land carbon gain is weakened by 17% over the 20th century, mainly due to increased human deforestation fires and associated escape fires (i.e., degradation fires) in the tropical humid forests, even though the decrease in burned area in many other regions due to human fire suppression acts to increase land carbon gain. The direct human effect on fire weakens the upward trend in global runoff throughout the century by 6% and enhances the upward trend in global evapotranspiration since 1945 by 7%. In addition, the above impacts in densely populated, highly developed (if population density > 0.1 person/km2), or moderately populated and developed regions are of opposite sign to those in other regions. Our study suggests that particular attention should be paid to human deforestation and degradation fires in the tropical humid forests when reconstructing and projecting fire carbon emissions and net atmosphere-land carbon exchange and estimating resultant impacts of direct human effect on fire.
Pigments which reflect infrared radiation from fire
Berdahl, Paul H.
1998-01-01
Conventional paints transmit or absorb most of the intense infrared (IR) radiation emitted by fire, causing them to contribute to the spread of fire. The present invention comprises a fire retardant paint additive that reflects the thermal IR radiation emitted by fire in the 1 to 20 micrometer (.mu.m) wavelength range. The important spectral ranges for fire control are typically about 1 to about 8 .mu.m or, for cool smoky fires, about 2 .mu.m to about 16 .mu.m. The improved inventive coatings reflect adverse electromagnetic energy and slow the spread of fire. Specific IR reflective pigments include titanium dioxide (rutile) and red iron oxide pigments with diameters of about 1 .mu.m to about 2 .mu.m and thin leafing aluminum flake pigments.
Extinguishing Agent for Magnesium Fire: Phases 5 and 6.
1987-07-01
This report documents the validation testing of the extinguishing system for metal fires developed as part of Phases I-IV. The results of this...system represented a reliable metal fire extinguishing system that could control and extinguish very large metal fires . The specifications developed for...the agent and for the delivery system are discussed in detail. Keywords: Fire suppression, Metal fires , Fire extinguishers.
FOCUS: a fire management planning system -- final report
Frederick W. Bratten; James B. Davis; George T. Flatman; Jerold W. Keith; Stanley R. Rapp; Theodore G. Storey
1981-01-01
FOCUS (Fire Operational Characteristics Using Simulation) is a computer simulation model for evaluating alternative fire management plans. This final report provides a broad overview of the FOCUS system, describes two major modules-fire suppression and cost, explains the role in the system of gaming large fires, and outlines the support programs and ways of...
Yellowstone National Park and the summer of fire
Diane Smith
2013-01-01
Because of their close relationships with fires, western forest ecosystems are considered fire dependent. If we hope to sustain the communities of trees, plants, and animals that characterize these wildland forests, we need to understand the natural role of fire, changes brought about by suppressing fire, and alternatives for restoring some reasonable semblance of the...
Fire Risk and Residential Development: A GIS Analysis
Jennifer L. Rechel; James B. Davis; Ted K. Bradshaw
1992-01-01
Population growth is rapid in rural areas in California. This growth into the wildland-urban interface makes fire protection and suppression more difficult. Fire managers have opportunities to reduce fire danger by improving housing development patterns; however, the overall density and placement of houses is usually set by criteria other than fire danger. By...
Benefits of hindsight: reestablishing fire on the landscape.
Sally Duncan
2001-01-01
Well-intentioned fire suppression efforts during the last 80 to 100 years have altered the structure of low-elevation forests in the interior Northwest. Historically, nondestructive, frequent, low-intensity fires have given way to larger, infrequent, severe, high-intensity fires. Because of altered fire behavior, forests now have increased fuel, and consequently, are...
36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2012 CFR
2012-07-01
... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...
36 CFR 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2014 CFR
2014-07-01
... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...
A method for determining fire history in coniferous forests in the Mountain West
Stephen F. Arno; Kathy M. Sneck
1977-01-01
Describes a method for determining historic fire frequency, intensity, and size from cross sections collected from fire-scarred trees and tree age classes determined through increment borings. Tells how to interpret the influence of fire in stand composition and structure and how to identify effects of modern fire suppression.
Assessing predictive services' 7-day fire potential outlook
Karin Riley; Crystal Stonesifer; Dave Calkin; Haiganoush Preisler
2015-01-01
The Predictive Services program was created under the National Wildfire Coordinating Group in 2001 to address the need for long- and short-term decision support information for fire managers and operations personnel. The primary mission of Predictive Services is to integrate fire weather, fire danger, and resource availability to enable strategic fire suppression...
Materials Science Research Rack-1 Fire Suppressant Distribution Test Report
NASA Technical Reports Server (NTRS)
Wieland, P. O.
2002-01-01
Fire suppressant distribution testing was performed on the Materials Science Research Rack-1 (MSRR-1), a furnace facility payload that will be installed in the U.S. Lab module of the International Space Station. Unlike racks that were tested previously, the MSRR-1 uses the Active Rack Isolation System (ARIS) to reduce vibration on experiments, so the effects of ARIS on fire suppressant distribution were unknown. Two tests were performed to map the distribution of CO2 fire suppressant throughout a mockup of the MSRR-1 designed to have the same component volumes and flowpath restrictions as the flight rack. For the first test, the average maximum CO2 concentration for the rack was 60 percent, achieved within 45 s of discharge initiation, meeting the requirement to reach 50 percent throughout the rack within 1 min. For the second test, one of the experiment mockups was removed to provide a worst-case configuration, and the average maximum CO2 concentration for the rack was 58 percent. Comparing the results of this testing with results from previous testing leads to several general conclusions that can be used to evaluate future racks. The MSRR-1 will meet the requirements for fire suppressant distribution. Primary factors that affect the ability to meet the CO2 distribution requirements are the free air volume in the rack and the total area and distribution of openings in the rack shell. The length of the suppressant flowpath and degree of tortuousness has little correlation with CO2 concentration. The total area of holes in the rack shell could be significantly increased. The free air volume could be significantly increased. To ensure the highest maximum CO2 concentration, the PFE nozzle should be inserted to the stop on the nozzle.
Climate and Wildfire in Mountains of the Western United States
NASA Astrophysics Data System (ADS)
Alfaro, E.; Westerling, A. L.; Cayan, D. R.
2004-12-01
Since the mid-1980s, there has been a dramatic increase in the area burned in wildfires in mountain forests of the western United States, with mean annual area burned nearly three and a half times higher compared to the preceding one and a half decades.(1) Concomitant increases in variability in annual area burned and in fire suppression costs pose a serious challenge for land management in the mountainous West. The variance in annual area burned since 1987 is nineteen times its previous level. Since managers must be prepared for the worst possible scenarios in every fire season, increased uncertainty about the scale of the western fire season each year imposes high costs on public agencies. Annual real suppression costs in western forests have more than doubled for the Forest Service since 1987, while the variance in annual suppression costs is over four times higher. Although federal agencies' fire suppression budgets have increased recently, they are still close to what would be spent in an "average" year that seldom occurs, while costs tend to fluctuate between low and high extremes. Modeling area burned and suppression costs as a function of climate variability alone, Westerling (2004, unpublished work) found that the probability of the Forest Service's suppression expenses exceeding the current annual suppression budget has exceeded 50% since 1987, a substantial increase from the one-in-three chance over the preceding 40 years. Recent progress in our understanding of the links between climate and wildfire, and in our ability to forecast some aspects of both climate and wildfire season severity a season or more in advance, offers some hope that these costs might be ameliorated through the integration of climate information into fire and fuels management. In addition to the effects of climate variability on wildfire, long-term biomass accumulations in some western ecosystems have fueled an increasing incidence of large, stand-replacing wildfires where such fires were previously rare. These severe large fires can result in erosion and changes in vegetation type, with consequences for water quality, stream flow, future biological productivity of the affected areas, and habitat loss for endangered species. Apart from their deleterious ecological consequences, severe fires can also dramatically affect amenity values for public lands and for homeowners living in the wildland-urban interface. In the National Fire Plan, land management agencies have committed to reducing fuels on millions of hectares of public lands. The primary means are mechanical removal, prescribed fire and wildland fire use. The Forest Service estimates they will need to spend hundreds of millions of dollars per year to meet their fuel reduction targets, while efforts in recent years have not kept up with the current rate of biomass increase. Use of climate information for targeting resources and scheduling prescribed burns could increase the efficiency of these efforts. In this study we review the fire history since 1970 for western mountain forests, and demonstrate apparent links between regional climate variability and decadal-scale changes in annual area burned. This analysis explores how wildfire size and frequency have varied over the past thirty-five years by elevation and latitude, and how climate indices such as precipitation, temperature, drought indices and the timing of spring runoff vary in importance for fire season severity by elevation in forests around the western United States.
Natural desulfurization in coal-fired units using Greek lignite.
Konidaris, Dimitrios N
2010-10-01
This paper analyzes the natural desulfurization process taking place in coal-fired units using Greek lignite. The dry scrubbing capability of Greek lignite appears to be extremely high under special conditions, which can make it possible for the units to operate within the legislative limits of sulfur dioxide (SO2) emissions. According to this study on several lignite-fired power stations in northern Greece, it was found that sulfur oxide emissions depend on coal rank, sulfur content, and calorific value. On the other hand, SO2 emission is inversely proportional to the parameter gammaCO2(max), which is equal to the maximum carbon dioxide (CO2) content by volume of dry flue gas under stoichiometric combustion. The desulfurization efficiency is positively correlated to the molar ratio of decomposed calcium carbonate to sulfur and negatively correlated to the free calcium oxide content of fly ash.
Drought sensitivity of Amazonian carbon balance revealed by atmospheric measurements
NASA Astrophysics Data System (ADS)
Gatti, L. V.; Gloor, M.; Miller, J. B.; Doughty, C. E.; Malhi, Y.; Domingues, L. G.; Basso, L. S.; Martinewski, A.; Correia, C. S. C.; Borges, V. F.; Freitas, S.; Braz, R.; Anderson, L. O.; Rocha, H.; Grace, J.; Phillips, O. L.; Lloyd, J.
2014-02-01
Feedbacks between land carbon pools and climate provide one of the largest sources of uncertainty in our predictions of global climate. Estimates of the sensitivity of the terrestrial carbon budget to climate anomalies in the tropics and the identification of the mechanisms responsible for feedback effects remain uncertain. The Amazon basin stores a vast amount of carbon, and has experienced increasingly higher temperatures and more frequent floods and droughts over the past two decades. Here we report seasonal and annual carbon balances across the Amazon basin, based on carbon dioxide and carbon monoxide measurements for the anomalously dry and wet years 2010 and 2011, respectively. We find that the Amazon basin lost 0.48+/-0.18 petagrams of carbon per year (PgCyr-1) during the dry year but was carbon neutral (0.06+/-0.1PgCyr-1) during the wet year. Taking into account carbon losses from fire by using carbon monoxide measurements, we derived the basin net biome exchange (that is, the carbon flux between the non-burned forest and the atmosphere) revealing that during the dry year, vegetation was carbon neutral. During the wet year, vegetation was a net carbon sink of 0.25+/-0.14PgCyr-1, which is roughly consistent with the mean long-term intact-forest biomass sink of 0.39+/-0.10PgCyr-1 previously estimated from forest censuses. Observations from Amazonian forest plots suggest the suppression of photosynthesis during drought as the primary cause for the 2010 sink neutralization. Overall, our results suggest that moisture has an important role in determining the Amazonian carbon balance. If the recent trend of increasing precipitation extremes persists, the Amazon may become an increasing carbon source as a result of both emissions from fires and the suppression of net biome exchange by drought.
Austin, Lauren V.; Silvis, Alexander; Ford, W. Mark; Muthersbaugh, Michael; Powers, Karen E.
2018-01-01
After decades of fire suppression in eastern North America, land managers now are prioritizing prescribed fire as a management tool to restore or maintain fire-adapted vegetation communities. However, in long—fire-suppressed landscapes, such as the central and southern Appalachians, it is unknown how bats will respond to prescribed fire in both riparian and upland forest habitats. To address these concerns, we conducted zero-crossing acoustic surveys of bat activity in burned, unburned, riparian, and non-riparian areas in the central Appalachians, Virginia, USA. Burn and riparian variables had model support (ΔAICc < 4) to explain activity of all bat species. Nonetheless, parameter estimates for these conditions were small and confidence intervals overlapped zero for all species, indicating effect sizes were marginal. Our results suggest that bats respond to fire differently between upland and riparian forest habitats, but overall, large landscape-level prescribed fire has a slightly positive to neutral impact on all bats species identified at our study site post—fire application.
Effectiveness of Prescribed Fire as a Fuel Treatment in Californian Coniferous Forests
Nicole M. Vaillant; JoAnn Fites-Kaufman; Scott L. Stephens
2006-01-01
Effective fire suppression for the past century has altered forest structure and increased fuel loads. Prescribed fire as a fuels treatment can reduce wildfire size and severity. This study investigates how prescribed fire affects fuel loads, forest structure, potential fire behavior, and modeled tree mortality at 80th, 90th, and 97.5th percentile fire weather...
30 CFR 75.1107-16 - Inspection of fire suppression devices.
Code of Federal Regulations, 2014 CFR
2014-07-01
... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire...
30 CFR 75.1107-16 - Inspection of fire suppression devices.
Code of Federal Regulations, 2012 CFR
2012-07-01
... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire...
30 CFR 75.1107-16 - Inspection of fire suppression devices.
Code of Federal Regulations, 2013 CFR
2013-07-01
... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA No. 13A—1971). National Fire Code No. 15 “Water Spray Fixed Systems for Fire Protection” (NFPA No. 15—1969). National Fire Code No. 17 “Dry Chemical Extinguishing Systems” (NFPA No. 17—1969). National Fire...
Matthew B. Dickinson; Kevin C. Ryan
2010-01-01
As prescribed fire use increases and the options for responding to wildfires continue to expand beyond suppression, the need for improving fire effects prediction capabilities be¬comes increasingly apparent. The papers in this Fire Ecology special issue describe recent advances in fire effects prediction for key classes of direct (first-order) fire effects. Important...
Joseph Marschall; Michael Stambaugh; Benjamin Jones; Richard Guyette; Patrick Brose; Daniel C. Dey
2016-01-01
Many fire-adapted ecosystems in the northeastern U.S. are converting to fire-intolerant vegetation communities due to fire suppression in the 20th century. Prescribed fire and other vegetation management activities that increase resilience and resistance to global changes are increasingly being implemented, particularly on public lands. For many fire-dependent...
Demonstration of Spacecraft Fire Safety Technology
NASA Technical Reports Server (NTRS)
Ruff, Gary A.; Urban, David L.
2012-01-01
During the Constellation Program, the development of spacecraft fire safety technologies were focused on the immediate questions related to the atmosphere of the habitable volume and implementation of fire detection, suppression, and postfire clean-up systems into the vehicle architectures. One of the difficulties encountered during the trade studies for these systems was the frequent lack of data regarding the performance of a technology, such as a water mist fire suppression system or an optically-based combustion product monitor. Even though a spacecraft fire safety technology development project was being funded, there was insufficient time and funding to address all the issues as they were identified. At the conclusion of the Constellation Program, these knowledge gaps formed the basis for a project proposed to the Advanced Exploration Systems (AES) Program. This project, subsequently funded by the AES Program and in operation since October 2011, has as its cornerstone the development of an experiment to be conducted on an ISS resupply vehicle, such as the European Space Agency (ESA) Automated Transfer Vehicle (ATV) or Orbital Science s Cygnus vehicle after it leaves the ISS and before it enters the atmosphere. The technology development efforts being conducted in this project include continued quantification of low- and partial-gravity maximum oxygen concentrations of spacecraft-relevant materials, development and verification of sensors for fire detection and post-fire monitoring, development of standards for sizing and selecting spacecraft fire suppression systems, and demonstration of post-fire cleanup strategies. The major technology development efforts are identified in this paper but its primary purpose is to describe the spacecraft fire safety demonstration being planned for the reentry vehicle.
Future Wildfire and Managed Fire Interactions in the Lake Tahoe Basin
NASA Astrophysics Data System (ADS)
Scheller, R.; Kretchun, A.
2017-12-01
Managing large forested landscape in the context of a changing climate and altered disturbance regimes presents new challenges and require integrated assessments of forest disturbance, management, succession, and the carbon cycle. Successful management under these circumstances will require information about trade-offs among multiple objectives and opportunities for spatially optimized landscape-scale management. Improved information about the effects of climate on forest communities, disturbance feedbacks, and the effectiveness of mitigation strategies enables actionable options for landscape managers. We evaluated the effects of fire suppression, wildfires, and forest fuel (thinning) treatments on the long-term carbon storage potential for Lake Tahoe Basin (LTB) forests under various climate futures. We simulated management scenarios that encompass fuel treatments across the larger landscape, beyond the Wildland Urban Interface. We improved upon current fire modeling under climate change via an integrated fire modeling module that, a) explicitly captures the influence of climate, fuels, topography, active fire management (e.g., fire suppression), and fuel treatments, and b) can be parameterized from available data, e.g., remote sensing, field reporting, fire databases, expert opinion. These improvements increase geographic flexibility and decrease reliance on broad historical fire regime statistics - imperfect targets for a no analog future and require minimal parameterization and calibration. We assessed the interactions among fuel treatments, prescribe fire, fire suppression, and stochastically recurring wildfires. Predicted changes in climate and ignition patterns in response to future climatic conditions, vegetation dynamics, and fuel treatments indicate larger potential long-term effects on C emissions, forest structure, and forest composition than prior studies.
Using topography to meet wildlife and fuels treatment objectives in fire-suppressed landscapes
Emma C. Underwood; Joshua H. Viers; James F. Quinn; Malcolm North
2010-01-01
Past forest management practices, fire suppression, and climate change are increasing the need to actively manage California Sierra Nevada forests for multiple environmental amenities. Here we present a relatively low-cost, repeatable method for spatially parsing the landscape to help the U.S. Forest Service manage for different forest and fuel conditions to meet...
Be careful what you wish for: The legacy of Smokey Bear
Geoffrey H. Donovan; Thomas C. Brown
2007-01-01
A century of wildfire suppression in the United States has led to increased fuel loading and large-scale ecological change across some of the nation's forests. Land management agencies have responded by increasing the use of prescribed fire and thinning. However, given the continued emphasis on fire suppression, current levels of funding for such fuel management...
Jeffrey P. Prestemon; Geoffrey H. Donovan
2008-01-01
Making input decisions under climate uncertainty often involves two-stage methods that use expensive and opaque transfer functions. This article describes an alternative, single-stage approach to such decisions using forecasting methods. The example shown is for preseason fire suppression resource contracting decisions faced by the United States Forest Service. Two-...
Analysis of USDA Forest Service fire-related expenditures 1970-1995
Ervin G. Schuster; David A. Cleaves; Enoch F. Bell
1997-01-01
Forest Service expenditures for fire presuppression and suppression activities increased from $61 million in FY 1970 to $951 million in FY 1994. Yet, real (net of inflation) expenditures have not increased significantly since FY 1970, if FY 1994 expenditures are excluded. During any given year, 56 percent of suppression expenditures are spent on supplies and services,...
Crystal S. Stonesifer; David E. Calkin; Michael S. Hand
2017-01-01
Wildland firefighting in the United States is a complex and costly enterprise. While there are strong seasonal signatures for fire occurrence in specific regions of the United States, spatiotemporal occurrence of wildfire activity can have high inter-annual variability. Suppression resources come from a variety of jurisdictions and provide a wide range of skills,...
Code of Federal Regulations, 2014 CFR
2014-07-01
... circuit continuity. If the system is not electrically operated, a means shall be provided to indicate the... secured computer system that is not susceptible to alteration. (3) Records shall be maintained at a... 30 Mineral Resources 1 2014-07-01 2014-07-01 false Fire suppression systems for diesel-powered...
Code of Federal Regulations, 2010 CFR
2010-07-01
... circuit continuity. If the system is not electrically operated, a means shall be provided to indicate the... secured computer system that is not susceptible to alteration. (3) Records shall be maintained at a... 30 Mineral Resources 1 2010-07-01 2010-07-01 false Fire suppression systems for diesel-powered...
Code of Federal Regulations, 2011 CFR
2011-07-01
... circuit continuity. If the system is not electrically operated, a means shall be provided to indicate the... secured computer system that is not susceptible to alteration. (3) Records shall be maintained at a... 30 Mineral Resources 1 2011-07-01 2011-07-01 false Fire suppression systems for diesel-powered...
Code of Federal Regulations, 2012 CFR
2012-07-01
... circuit continuity. If the system is not electrically operated, a means shall be provided to indicate the... secured computer system that is not susceptible to alteration. (3) Records shall be maintained at a... 30 Mineral Resources 1 2012-07-01 2012-07-01 false Fire suppression systems for diesel-powered...
Code of Federal Regulations, 2013 CFR
2013-07-01
... circuit continuity. If the system is not electrically operated, a means shall be provided to indicate the... secured computer system that is not susceptible to alteration. (3) Records shall be maintained at a... 30 Mineral Resources 1 2013-07-01 2013-07-01 false Fire suppression systems for diesel-powered...
Long-term demographic trends in a fire-suppressed mixed-conifer forest
Carrie R. Levine; Flora Krivak-Tetley; Natalie S. van Doorn; Jolie-Anne S. Ansley; John J. Battles
2016-01-01
In the western United States, forests are experiencing novel environmental conditions related to a changing climate and a suppression of the historical fire regime. Mixed-conifer forests, considered resilient to disturbance due to their heterogeneity in structure and composition, appear to be shifting to a more homogeneous state, but the timescale of these shifts is...
Wildfire risk and home purchase decisions.
Patricia Champ; Geoffrey Donovan; Christopher Barth
2008-01-01
In the last 20 years, wildfire damages and the costs of wildfire suppression have risen dramatically. This trend has been attributed to three main factors: climate change, increased fuel loads from a century of wildfire suppression, and increased housing development in fire-prone areas., There is little that fire managers can do about climate change, and current fuel...
Syn-pandemic Fire Suppression in the Tropical Americas During European Conquest
NASA Astrophysics Data System (ADS)
Nevle, R. J.; Bird, D. K.
2006-12-01
A new reconstruction of the biomass burning history of the tropical Americas during the past 5 millennia documents the expansion of fire use by Mesoamerican and Amazonian agriculturalists and a subsequent period of fire suppression beginning ~500 years BP. Fire suppression is synchronous with the collapse of the American indigenous population during European conquest. The present work synthesizes microscopic charcoal accumulation records preserved in lake, bog, and basin sediments from 14 sites in Central America and equatorial South America to reconstruct regional variation in charcoal accumulation rates, averaged over 200-year increments, relative to the mean rate of regional charcoal accumulation during the past 5 millennia. This study builds upon prior fire history reconstructions by synthesizing a substantially greater number of stratigraphic charcoal accumulation sequences to resolve features of the Late Holocene biomass burning record in the tropical Americas. We find that between ~5000 and ~4000 years BP, charcoal accumulation generally persisted at rates >1 standard deviation (s.d.) below the 5-millennium mean. Subsequently charcoal accumulation rates fluctuated until ~3000 years BP and then increased, maintaining an average level >0.5 s.d. above the 5-millenium mean until ~500 years BP. After ~500 years BP, charcoal accumulation rates dropped to values below the 5000-year mean and remained suppressed for the next several centuries. The variation in charcoal accumulation rates over the past 5000 years reflects both climatic and anthropogenic factors affecting the regional fire history of the tropical Americas. The transition to above-average charcoal accumulation rates after 3000 years BP is synchronous with a trend toward a drier climate in the circum-Caribbean region and expanding forest clearance and cultivation by Mesoamerican and Amazonian societies. The subsequent, prolonged period of enhanced biomass burning between ~3000 and ~500 years BP is punctuated by three intervals of low charcoal accumulation, reflecting intermittent episodes of fire-suppression lasting <200 years. The latest and most pronounced of these low-fire intervals occurs at ~1100 years BP and corresponds to the Classic Maya collapse. The persistence of low charcoal accumulation rates for several centuries after ~500 years BP is parsimoniously explained by a reduction of agriculture-related biomass burning due to syn-pandemic population collapse. During European conquest, pandemics killed ~90% of the indigenous American population, estimated to represent ~20% of the 16^{th} century global population. The suppression of biomass burning after ~500 years BP is a unique feature of the fire history of Central and equatorial South America relative to other regions of the globe, where rates of charcoal accumulation are typically >0.2 s.d. above their Holocene mean values. Syn-pandemic fire suppression in the tropical Americas is associated with massive regional reforestation and sequestration of carbon into the terrestrial biosphere, which contributed to the ~2% global reduction in atmospheric CO2 levels and the 0.1 per mil increase in δ13C of atmospheric CO2 from 1500 to 1700 A.D.
Incipient I Fire Brigade Training & Certification.
ERIC Educational Resources Information Center
Anoka-Hennepin Technical Coll., Minneapolis, MN.
This document contains course materials for the minimum general and Koch-specific requirements for the fire suppression training and education portion of the integrated industrial emergency response team training program. The various levels of performance were developed with the National Fire standard 600, Private Fire Brigades. The training is…
Larry Bradshaw; Roberta Bartlette; John McGinely; Karl Zeller
2003-01-01
The Hayman Fire in June 2002 was heavily influenced by antecedent regional weather conditions, culminating in a series of daily weather events that aligned to produce widely varying fire behavior. This review of weather conditions associated with the Hayman Fire consists of two parts: 1) A brief overview of prior conditions as described by a regional climate review and...
Fire technology abstracts, volume 4. Cumulative indexes
NASA Astrophysics Data System (ADS)
1982-03-01
Cumulative subject, author, publisher, and report number indexes referencing articles, books, reports, and patents are provided. The dynamics of fire, behavior and properties of materials, fire modeling and test burns, fire protection, fire safety, fire service organization, apparatus and equipment, fire prevention suppression, planning, human behavior, medical problems, codes and standards, hazard identification, safe handling of materials, and insurance economics of loss and prevention are among the subjects covered.
Forest-fire model with natural fire resistance.
Yoder, Mark R; Turcotte, Donald L; Rundle, John B
2011-04-01
Observations suggest that contemporary wildfire suppression practices in the United States have contributed to conditions that facilitate large, destructive fires. We introduce a forest-fire model with natural fire resistance that supports this theory. Fire resistance is defined with respect to the size and shape of clusters; the model yields power-law frequency-size distributions of model fires that are consistent with field observations in the United States, Canada, and Australia.
Wildland fire emissions, carbon, and climate: Science overview and knowledge needs
William T. Sommers; Rachel A. Loehman; Colin C. Hardy
2014-01-01
Wildland fires have influenced the global carbon cycle for 420 million years of Earth history, interacting with climate to define vegetation characteristics and distributions, trigger abrupt ecosystem shifts, and move carbon among terrestrial and atmospheric pools. Carbon dioxide (CO2) is the dominant driver of ongoing climate change and the principal emissions...
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2010 CFR
2010-10-01
... 46 Shipping 7 2010-10-01 2010-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2011 CFR
2011-10-01
... 46 Shipping 7 2011-10-01 2011-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2012 CFR
2012-10-01
... 46 Shipping 7 2012-10-01 2012-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2013 CFR
2013-10-01
... 46 Shipping 7 2013-10-01 2013-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
46 CFR 193.50-5 - Classification.
Code of Federal Regulations, 2014 CFR
2014-10-01
... 46 Shipping 7 2014-10-01 2014-10-01 false Classification. 193.50-5 Section 193.50-5 Shipping COAST... Details § 193.50-5 Classification. (a) Hand portable fire extinguishers and semiportable fire...) Classification Type Size Soda-acid and water, gals. Foam, gals. Carbon dioxide, lbs. Dry chemical, lbs. A II 21/2...
A fire management simulation model using stochastic arrival times
Eric L. Smith
1987-01-01
Fire management simulation models are used to predict the impact of changes in the fire management program on fire outcomes. As with all models, the goal is to abstract reality without seriously distorting relationships between variables of interest. One important variable of fire organization performance is the length of time it takes to get suppression units to the...
Prescribed fire in North American forests and woodlands: history, current practice, and challenges
Kevin C. Ryan; Eric E. Knapp; J. Morgan Varner
2013-01-01
Whether ignited by lightning or by Native Americans, fire once shaped many North American ecosystems. Euro-American settlement and 20th-century fire suppression practices drastically altered historic fire regimes, leading to excessive fuel accumulation and uncharacteristically severe wildfires in some areas and diminished flammability resulting from shifts to more fire...
36 CFR § 1234.12 - What are the fire safety requirements that apply to records storage facilities?
Code of Federal Regulations, 2013 CFR
2013-07-01
... records storage facilities? (a) The fire detection and protection systems must be designed or reviewed by a licensed fire protection engineer. If the system was not designed by a licensed fire protection... engineer that describes the design intent of the fire detection and suppression system, detailing the...
Danny L. Fry; Scott L. Stephens; Brandon M. Collins; Malcolm North; Ernesto Franco-Vizcaino; Samantha J. Gill
2014-01-01
In Mediterranean environments in western North America, historic fire regimes in frequent-fire conifer forests are highly variable both temporally and spatially. This complexity influenced forest structure and spatial patterns, but some of this diversity has been lost due to anthropogenic disruption of ecosystem processes, including fire. Information from reference...
Monitoring post-fire vegetation regeneration in a Madrean ecosystem
Kelley J. O' Neal; John Rogan; Stephen R. Yool
2005-01-01
Fire suppression over the past century has contributed to the conversion of grasslands to shrublands in Sky Island communities. Two prescribed fires were ignited in the Peloncillo Mountains: Baker Canyon in 1995 and Maverick Spring in 1997. Remote sensing data were used to examine prescribed fire effectiveness in reducing shrub cover and to monitor post-fire...
Lessons learned from prescribed fire in ponderosa pine forests of the southern Sierra Nevada
Karen E. Bagne; Kathryn L. Purcell
2009-01-01
Prescribed fire is a commonly used management tool in fire-suppressed ponderosa pine (Pinus ponderosa) forests, but effects of these fires on birds are largely unstudied. We investigated both direct and indirect impacts on breeding birds in ponderosa pine forests of the southern Sierra Nevada where fires were applied in the spring. Following...
Studying interregional wildland fire engine assignments for large fire suppression
Erin J. Belval; Yu Wei; David E. Calkin; Crystal S. Stonesifer; Matthew P. Thompson; John R. Tipton
2017-01-01
One crucial component of large fire response in the United States (US) is the sharing of wildland firefighting resources between regions: resources from regions experiencing low fire activity supplement resources in regions experiencing high fire activity. An important step towards improving the efficiency of resource sharing and related policies is to develop a better...
2011-07-01
cameras were installed around the test pan and an underwater GoPro ® video camera recorded the fire from below the layer of fuel. 3.2.2. Camera Images...Distribution A: Approved for public release; distribution unlimited. 3.2.3. Video Images A GoPro video camera with a wide angle lens recorded the tests...camera and the GoPro ® video camera were not used for fire suppression experiments. 3.3.2. Test Pans Two ¼-in thick stainless steel test pans were
Kathryn L. Purcell; Scott L. Stephens
2005-01-01
Fire was once an important component of the disturbance regime in oak woodlands of the Sierra Nevada foothills. In addition to lightning-ignited fires, anthropogenic sources of ignition have historically been important until fire suppression activities in the mid- 20th century lengthened fire return intervals. Few fire history studies have addressed oak woodlands, and...
Scott L. Stephens; Carl N. Skinner; Samantha J. Gill
2003-01-01
Conifer forests in northwestern Mexico have not experienced systematic fire suppression or logging, making them unique in western North America. Fire regimes of Pinus jeffreyi Grev. & Balf. mixed conifer forests in the Sierra San Pedro Martir, Baja California, Mexico, were determined by identifying 105 fire dates from 1034 fire scars in 105 specimens. Fires were...
Harold S.J. Zald; Andrew N. Gray; Malcolm North; Ruth A. Kern
2008-01-01
Fire is a driver of ecosystem patterns and processes in forests globally, but natural fire regimes have often been altered by decades of active fire management. Following almost a century of fire suppression, many Western U.S. forests have greater fuel levels, higher tree densities, and are now dominated by fire-sensitive, shade-tolerant species. These fuel-loaded...
Verification study of an emerging fire suppression system
Cournoyer, Michael E.; Waked, R. Ryan; Granzow, Howard N.; ...
2016-01-01
Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation andmore » mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.« less
Verification study of an emerging fire suppression system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cournoyer, Michael E.; Waked, R. Ryan; Granzow, Howard N.
Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Moreover, plutonium gloveboxes present harsh environmental conditions for polymer materials; these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. Several studies have been conducted to determine the robustness of selfcontained fire extinguishers in plutonium gloveboxes in a nuclear facility, verification tests must be performed. These tests include activation and mass loss calorimeter tests. In addition, compatibility issues with chemical components of the self-contained fire extinguishers need to be addressed. Our study presents activation andmore » mass loss calorimeter test results. After extensive studies, no critical areas of concern have been identified for the plutonium glovebox application of Fire Foe™, except for glovebox operations that use large quantities of bulk plutonium or uranium metal such as metal casting and pyro-chemistry operations.« less
36 CFR 211.4 - Cooperation for fire prevention and control.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 36 Parks, Forests, and Public Property 2 2010-07-01 2010-07-01 false Cooperation for fire... AGRICULTURE ADMINISTRATION Cooperation § 211.4 Cooperation for fire prevention and control. The Forest Service... will result in mutual benefit in the prevention and suppression of forest fires: Provided, That the...
What is limiting more flexible fire management—public or agency pressure?
Toddi A. Steelman; Sarah M. McCaffrey
2011-01-01
Conventional wisdom within American federal fire management agencies suggests that external influence such as community or political pressure for aggressive suppression are key factors circumscribing the ability to execute less aggressive fire management strategies. Thus, a better understanding of external constraints on fire management options is essential. This...
Sharon M. Hood; Donald Long; Melanie Miller; Kevin C. Ryan
2007-01-01
Many areas throughout the United States are facing the triple threat of increasing fire severity, residential growth in areas prone to wildland fire, and suppression costs and losses. In addition, substantial changes are occurring in the way we plan and implement management on federal lands relative to use of wildland fire, prescribed fire, and mechanical fuel...
36 CFR 211.4 - Cooperation for fire prevention and control.
Code of Federal Regulations, 2011 CFR
2011-07-01
... 36 Parks, Forests, and Public Property 2 2011-07-01 2011-07-01 false Cooperation for fire... AGRICULTURE ADMINISTRATION Cooperation § 211.4 Cooperation for fire prevention and control. The Forest Service... will result in mutual benefit in the prevention and suppression of forest fires: Provided, That the...
30 CFR 75.1107-16 - Inspection of fire suppression devices.
Code of Federal Regulations, 2011 CFR
2011-07-01
...-16 Section 75.1107-16 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA...
30 CFR 75.1107-16 - Inspection of fire suppression devices.
Code of Federal Regulations, 2010 CFR
2010-07-01
...-16 Section 75.1107-16 Mineral Resources MINE SAFETY AND HEALTH ADMINISTRATION, DEPARTMENT OF LABOR COAL MINE SAFETY AND HEALTH MANDATORY SAFETY STANDARDS-UNDERGROUND COAL MINES Fire Protection Fire... Systems” (NFPA No. 11A—1970). National Fire Code No. 13A “Care and Maintenance of Sprinkler Systems” (NFPA...
Effects of post-fire soil hydrophobicity on inorganic soil nitrogen and sulfur cycling
USDA-ARS?s Scientific Manuscript database
Fire plays an important role in many native ecosystems, and its suppression has increased woody encroachment across the globe. Restoring native herbaceous communities following fire in encroached systems is often challenging. Post-fire soil hydrophobicity is one factor that may further limit site re...
Pigments which reflect infrared radiation from fire
Berdahl, P.H.
1998-09-22
Conventional paints transmit or absorb most of the intense infrared (IR) radiation emitted by fire, causing them to contribute to the spread of fire. The present invention comprises a fire retardant paint additive that reflects the thermal IR radiation emitted by fire in the 1 to 20 micrometer ({micro}m) wavelength range. The important spectral ranges for fire control are typically about 1 to about 8 {micro}m or, for cool smoky fires, about 2 {micro}m to about 16 {micro}m. The improved inventive coatings reflect adverse electromagnetic energy and slow the spread of fire. Specific IR reflective pigments include titanium dioxide (rutile) and red iron oxide pigments with diameters of about 1 {micro}m to about 2 {micro}m and thin leafing aluminum flake pigments. 4 figs.
Reducing Manpower for a Technologically Advanced Ship
2010-01-27
Watchstations by 84% (119 to 34) “ Autonomic ” Fire Suppression System AFSS is designed to automatically: (1) Isolate damage to firemain piping... System (IPS) Advanced VLS Autonomic Fire Suppression Hull Form Scale Models Total Ship Computing Environment (TSCE) Integrated Undersea...Warfare (IUSW) System ( AFSS ) 8 Total Ship Organization Ship C3I Engage Support Technical Director TSCEI Sense Integrated Product Teams TSSE Director
Francisco Rodríguez y Silva; Armando González-Cabán
2013-01-01
The abandonment of land, the high energy load generated and accumulated by vegetation covers, climate change and interface scenarios in Mediterranean forest ecosystems are demanding serious attention to forest fire conditions. This is particularly true when dealing with the budget requirements for undertaking protection programs related to the state of current and...
The effects of fire suppression on Bachman's sparrows in upland pine forests of eastern Texas
Richard N. Conner; Clifford E. Shackelford; Richard R. Schaefer; Daniel Saenz
2005-01-01
We studied the effects of 8 years of fire suppression on shrub-level vegetation, Bachman's Sparrows (Aimophila aestivalis), and selected forest bird species between 1995 and 2003in eastern Texas. Woody shrub-level vegetation between ground level and 3 m above the ground, measured using a leaf area index, increased significantly in all sites !n...
Prediction suppression and surprise enhancement in monkey inferotemporal cortex.
Ramachandran, Suchitra; Meyer, Travis; Olson, Carl R
2017-07-01
Exposing monkeys, over the course of days and weeks, to pairs of images presented in fixed sequence, so that each leading image becomes a predictor for the corresponding trailing image, affects neuronal visual responsiveness in area TE. At the end of the training period, neurons respond relatively weakly to a trailing image when it appears in a trained sequence and, thus, confirms prediction, whereas they respond relatively strongly to the same image when it appears in an untrained sequence and, thus, violates prediction. This effect could arise from prediction suppression (reduced firing in response to the occurrence of a probable event) or surprise enhancement (elevated firing in response to the omission of a probable event). To identify its cause, we compared firing under the prediction-confirming and prediction-violating conditions to firing under a prediction-neutral condition. The results provide strong evidence for prediction suppression and limited evidence for surprise enhancement. NEW & NOTEWORTHY In predictive coding models of the visual system, neurons carry signed prediction error signals. We show here that monkey inferotemporal neurons exhibit prediction-modulated firing, as posited by these models, but that the signal is unsigned. The response to a prediction-confirming image is suppressed, and the response to a prediction-violating image may be enhanced. These results are better explained by a model in which the visual system emphasizes unpredicted events than by a predictive coding model. Copyright © 2017 the American Physiological Society.
Suppression and Structure of Low Strain Rate Nonpremixed Flames
NASA Technical Reports Server (NTRS)
Hamins, Anthony; Bundy, Matthew; Park, Woe Chul; Lee, Ki Yong; Logue, Jennifer
2003-01-01
The agent concentration required to achieve suppression of low strain rate nonpremixed flames is an important fire safety consideration. In a microgravity environment such as a space platform, unwanted fires will likely occur in near quiescent conditions where strain rates are very low. Diffusion flames typically become more robust as the strain rate is decreased. When designing a fire suppression system for worst-case conditions, low strain rates should be considered. The objective of this study is to investigate the impact of radiative emission, flame strain, agent addition, and buoyancy on the structure and extinction of low strain rate nonpremixed flames through measurements and comparison with flame simulations. The suppression effectiveness of a suppressant (N2) added to the fuel stream of low strain rate methane-air diffusion flames was measured. Flame temperature measurements were attained in the high temperature region of the flame (T greater than 1200 K) by measurement of thin filament emission intensity. The time varying temperature was measured and simulated as the flame made the transition from normal to microgravity conditions and as the flame extinguished.
Reliability study of an emerging fire suppression system
Miller, David A.; Rossati, Lyric M.; Fritz, Nathan K.; ...
2015-11-01
Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Plutonium gloveboxes are known to present harsh environmental conditions for polymer materials, these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. The primary component of interest in self-contained fire extinguishers is the nylon 6-6 machined tube that comprises the main body of the system.Thermo-mechanical modeling and characterization of nylon 6-6 for use in plutonium glovebox applications has been carried out. Data has been generated regarding property degradation leading to poor, or reduced, engineering performancemore » of nylon 6-6 components. In this study, nylon 6-6 tensile specimens conforming to the casing of self-contained fire extinguisher systems have been exposed to hydrochloric, nitric, and sulfuric acids. This information was used to predict the performance of a load bearing engineering component comprised of nylon 6-6 and designed to operate in a consistent manner over a specified time period. The study provides a fundamental understanding of the engineering performance of the fire suppression system and the effects of environmental degradation due to acid exposure on engineering performance. Data generated help identify the limitations of self-contained fire extinguishers. No critical areas of concern for plutonium glovebox applications of nylon 6-6 have been identified when considering exposure to mineral acid.« less
Reliability study of an emerging fire suppression system
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, David A.; Rossati, Lyric M.; Fritz, Nathan K.
Self-contained fire extinguishers are a robust, reliable and minimally invasive means of fire suppression for gloveboxes. Plutonium gloveboxes are known to present harsh environmental conditions for polymer materials, these include radiation damage and chemical exposure, both of which tend to degrade the lifetime of engineered polymer components. The primary component of interest in self-contained fire extinguishers is the nylon 6-6 machined tube that comprises the main body of the system.Thermo-mechanical modeling and characterization of nylon 6-6 for use in plutonium glovebox applications has been carried out. Data has been generated regarding property degradation leading to poor, or reduced, engineering performancemore » of nylon 6-6 components. In this study, nylon 6-6 tensile specimens conforming to the casing of self-contained fire extinguisher systems have been exposed to hydrochloric, nitric, and sulfuric acids. This information was used to predict the performance of a load bearing engineering component comprised of nylon 6-6 and designed to operate in a consistent manner over a specified time period. The study provides a fundamental understanding of the engineering performance of the fire suppression system and the effects of environmental degradation due to acid exposure on engineering performance. Data generated help identify the limitations of self-contained fire extinguishers. No critical areas of concern for plutonium glovebox applications of nylon 6-6 have been identified when considering exposure to mineral acid.« less
Fast and safe gas detection from underground coal fire by drone fly over.
Dunnington, Lucila; Nakagawa, Masami
2017-10-01
Underground coal fires start naturally or as a result of human activities. Besides burning away the important non-renewable energy resource and causing financial losses, burning coal seams emit carbon dioxide, carbon monoxide, sulfur oxide and methane, and is a leading cause of smog, acid rain, global warming, and air toxins. In the U.S. alone, the combined cost of coal-fire remediation projects that have been completed, budgeted, or projected by the U.S. Department of the Interior's Office of Surface Mining Remediation and Enforcement (OSM), exceeds $1 billion. It is estimated that these fires generate as much as 3% of the world's annual carbon dioxide emissions and consume as much as 5% of its minable coal. Considering the magnitude of environmental impact and economic loss caused by burning underground coal seams, we have developed a new, safe, reliable surface measurement of coal fire gases to assess the nature of underground coal fires. We use a drone mounted with gas sensors. Drone collected gas concentration data provides a safe alternative for evaluating the rank of a burning coal seam. In this study, a new method of determining coal rank by gas ratios is developed. Coal rank is valuable for defining parameters of a coal seam such as burn temperature, burn rate, and volume of burning seam. Copyright © 2017 Elsevier Ltd. All rights reserved.
Ichikawa, Shinichiro; Tada, Mizuki; Iwasawa, Yasuhiro; Ikariya, Takao
2005-02-21
Chemoselective hydrogenation of halogenated nitrobenzenes over Pt/C catalysts proceeds effectively in supercritical carbon dioxide (scCO2) to produce halogenated anilines with excellent selectivity; the rate of the hydrogenation of nitro groups is markedly enhanced in scCO2 compared to the neat reaction, and the dehalogenation reaction is significantly suppressed.
Köster, Egle; Köster, Kajar; Berninger, Frank; Aaltonen, Heidi; Zhou, Xuan; Pumpanen, Jukka
2017-12-01
Forest fires are one of the most important natural disturbances in boreal forests, and their occurrence and severity are expected to increase as a result of climate warming. A combination of factors induced by fire leads to a thawing of the near-surface permafrost layer in subarctic boreal forest. Earlier studies reported that an increase in the active layer thickness results in higher carbon dioxide (CO 2 ) and methane (CH 4 ) emissions. We studied changes in CO 2 , CH 4 and nitrous oxide (N 2 O) fluxes in this study, and the significance of several environmental factors that influence the greenhouse gas (GHG) fluxes at three forest sites that last had fires in 2012, 1990 and 1969, and we compared these to a control area that had no fire for at least 100years. The soils in our study acted as sources of CO 2 and N 2 O and sinks for CH 4 . The elapsed time since the last forest fire was the only factor that significantly influenced all studied GHG fluxes. Soil temperature affected the uptake of CH 4 , and the N 2 O fluxes were significantly influenced by nitrogen and carbon content of the soil, and by the active layer depth. Results of our study confirm that the impacts of a forest fire on GHGs last for a rather long period of time in boreal forests, and are influenced by the fire induced changes in the ecosystem. Copyright © 2017 Elsevier B.V. All rights reserved.
Introduction to the effects of wildland fire on aquatic ecosystems in the Western USA
Rieman, B.; Gresswell, Robert E.; Young, M.; Luce, C.
2003-01-01
The management of wildfire has long been controversial. The role of fire and fire-related management in terrestrial and aquatic ecosystems has become an important focus in recent years, but the general debate is not new. In his recent book, Stephen Pyne (2001 )describes the political and scientific debate surrounding the creation of the U.S. Forest Service and the emergence of fire suppression as a central tenet of wildland management. Essentially, views in the first decade of the 20th century focused on fire as good or evil: a tool that might benefit other resources or interests (e.g. Indian burning) and mitigate larger more destructive fires, or a threat to the recruitment and productivity of newly designated forest reserves. The “great fires” in the Western USA in 1910 and the associated loss of human life and property largely forged the public and political will to suppress fire on a massive scale.
Code of Federal Regulations, 2010 CFR
2010-10-01
... SECURITY DISASTER ASSISTANCE FEDERAL DISASTER ASSISTANCE Fire Suppression Assistance § 206.390 General. When the Assistant Administrator for the Disaster Assistance Directorate determines that a fire or fires threaten such destruction as would constitute a major disaster, assistance may be authorized...
Code of Federal Regulations, 2011 CFR
2011-10-01
... SECURITY DISASTER ASSISTANCE FEDERAL DISASTER ASSISTANCE Fire Suppression Assistance § 206.390 General. When the Assistant Administrator for the Disaster Assistance Directorate determines that a fire or fires threaten such destruction as would constitute a major disaster, assistance may be authorized...
DOE Office of Scientific and Technical Information (OSTI.GOV)
Holden, Sandra R.; Berhe, Asmeret A.; Treseder, Kathleen K.
Climate warming is projected to increase the frequency and severity of wildfires in boreal forests, and increased wildfire activity may alter the large soil carbon (C) stocks in boreal forests. Changes in boreal soil C stocks that result from increased wildfire activity will be regulated in part by the response of microbial decomposition to fire, but post-fire changes in microbial decomposition are poorly understood. Here, we investigate the response of microbial decomposition to a boreal forest fire in interior Alaska and test the mechanisms that control post-fire changes in microbial decomposition. We used a reciprocal transplant between a recently burnedmore » boreal forest stand and a late successional boreal forest stand to test how post-fire changes in abiotic conditions, soil organic matter (SOM) composition, and soil microbial communities influence microbial decomposition. We found that SOM decomposing at the burned site lost 30.9% less mass over two years than SOM decomposing at the unburned site, indicating that post-fire changes in abiotic conditions suppress microbial decomposition. Our results suggest that moisture availability is one abiotic factor that constrains microbial decomposition in recently burned forests. In addition, we observed that burned SOM decomposed more slowly than unburned SOM, but the exact nature of SOM changes in the recently burned stand are unclear. Finally, we found no evidence that post-fire changes in soil microbial community composition significantly affect decomposition. Taken together, our study has demonstrated that boreal forest fires can suppress microbial decomposition due to post-fire changes in abiotic factors and the composition of SOM. Models that predict the consequences of increased wildfires for C storage in boreal forests may increase their predictive power by incorporating the observed negative response of microbial decomposition to boreal wildfires.« less
Implications of changing fire regimes for aquatic ecosystems
Bruce Rieman; Charles H. Luce; Jason B. Dunham; Amanda L. Rosenberger
2005-01-01
Climate change and past management, including fire suppression, have been linked to changing patterns of fire in the last century. It is widely believed that many forested areas have moved from a regime of low and mixed severity fire to more frequent and more continuous high severity fire (Hessburg and Agee 2003). There is growing concern among ecologists and natural...
The Missoula Fire Sciences Laboratory: A 50-year dedication to understanding wildlands and fire
Diane M. Smith
2012-01-01
In 1960, the USDA Forest Service established the Northern Forest Fire Laboratory (now the Missoula Fire Sciences Laboratory) to find scientific solutions for better managing the nation's wildland resources and to research ways to improve forest fire prevention and suppression. This new state-of-the-art research facility did not emerge from a vacuum, however. This...
Presettlement fire regime and vegetation mapping in Southeastern Coastal Plain forest ecosystems
Andrew D. Bailey; Robert Mickler; Cecil Frost
2007-01-01
Fire-adapted forest ecosystems make up 95 percent of the historic Coastal Plain vegetation types in the Southeastern United States. Fire suppression over the last century has altered the species composition of these ecosystems, increased fuel loads, and increased wildfire risk. Prescribed fire is one management tool used to reduce fuel loading and restore fire-adapted...
Fire frequency effects on fuel loadings in pine-oak forests of the Madrean Province
Francisco J. Escobedo; Peter F. Ffolliott; Gerald J. Gottfried; Florentino Garza
2001-01-01
Loadings of downed woody fuels in pine-oak forests of the Madrean Province are heavier on sites in southeastern Arizona with low fire frequencies and lower on sites in northeastern Sonora, Mexico, with high fire frequencies. Low fire frequencies in southeastern Arizona are attributed largely to past land uses and the fire suppression policies of land management...
A review of challenges to determining and demonstrating efficiency of large fire management
Matthew P. Thompson; Francisco Rodriguez y Silva; David E. Calkin; Michael S. Hand
2017-01-01
Characterising the impacts of wildland fire and fire suppression is critical information for fire management decision-making. Here, we focus on decisions related to the rare larger and longer-duration fire events, where the scope and scale of decision-making can be far broader than initial response efforts, and where determining and demonstrating efficiency of...
Evaluating risks and benefits of wildland fire at landscape scales
Carol Miller; Peter B. Landres; Paul B. Alaback
2000-01-01
Fire suppression has resulted in severe management challenges, especially in the wildland-urban interface zone. Fire managers seek to reduce fuels and risks in the interface zone, while striving to return the natural role of fire to wildland ecosystems. Managers must balance the benefits of wildland fire on ecosystem health against the values that need to be protected...
Karin L. Riley; Crystal Stonesifer; Haiganoush Preisler; Dave Calkin
2014-01-01
Can fire potential forecasts assist with pre-positioning of fire suppression resources, which could result in a cost savings to the United States government? Here, we present a preliminary assessment of the 7-Day Fire Potential Outlook forecasts made by the Predictive Services program. We utilized historical fire occurrence data and archived forecasts to assess how...
Fire Safety in Extraterrestrial Environments
NASA Technical Reports Server (NTRS)
Friedman, Robert
1998-01-01
Despite rigorous fire-safety policies and practices, fire incidents are possible during lunar and Martian missions. Fire behavior and hence preventive and responsive safety actions in the missions are strongly influenced by the low-gravity environments in flight and on the planetary surfaces. This paper reviews the understanding and key issues of fire safety in the missions, stressing flame spread, fire detection, suppression, and combustion performance of propellants produced from Martian resources.
Manual Fire Suppression Methods on Typical Machinery Space Spray Fires
1990-07-31
Aqueous Film Forming Foam Manuscnpt approved April 25, 1990. ( AFFF ), has been incorporated in machinery space fire protection systems to...distribution unlimited. 13. ABSTRACT (Maximum 200 words) A series of tests was conducted to evaluate the effectiveness of Aqueous Film Forming Foami ( AFFF ...machinery space fire protection systems to control running fuel and fuel spray fires (PKP side of TAFES), and bilge fires ( aqueous film forming foam
Western forest, fire risk, and climate change
Valerie Rapp
2004-01-01
Climate warming may first show up in forests as increased growth, which occurs as warmer temperatures, increased carbon dioxide, and more precipitation encourage higher rates of photosynthesis. The second way that climate change may show up in forests is through changes in disturbance regimesâthe long-term patterns of fire, drought, insects, and diseases that are basic...
Western forests, fire risk, and climate change.
Valerie Rapp
2004-01-01
Climate warming may first show up in forests as increased growth, which occurs as warmer temperatures, increased carbon dioxide, and more precipitation encourage higher rates of photosynthesis. The second way that climate change may show up in forests is through changes in disturbance regimesâthe long-term patterns of fire, drought, insects, and diseases that are basic...
Laboratory investigation of fire radiative energy and smoke aerosol emissions
Charles Ichoku; J. Vanderlei Martins; Yoram J. Kaufman; Martin J. Wooster; Patrick H. Freeborn; Wei Min Hao; Stephen Baker; Cecily A. Ryan; Bryce L. Nordgren
2008-01-01
Fuel biomass samples from southern Africa and the United States were burned in a laboratory combustion chamber while measuring the biomass consumption rate, the fire radiative energy (FRE) release rate (Rfre), and the smoke concentrations of carbon monoxide (CO), carbon dioxide (CO2), and particulate matter (PM). The PM mass emission rate (RPM) was quantified from...
A mathematical model of a large open fire
NASA Technical Reports Server (NTRS)
Harsha, P. T.; Bragg, W. N.; Edelman, R. B.
1981-01-01
A mathematical model capable of predicting the detailed characteristics of large, liquid fuel, axisymmetric, pool fires is described. The predicted characteristics include spatial distributions of flame gas velocity, soot concentration and chemical specie concentrations including carbon monoxide, carbon dioxide, water, unreacted oxygen, unreacted fuel and nitrogen. Comparisons of the predictions with experimental values are also given.
Fire and logging history at Huckleberry Hallow, Shannon County, Missouri
Richard P. Guyette; Daniel C. Dey
1997-01-01
Disturbances such as windthrow, fire and timber harvest significantly effect how forest ecosystems develop. We have and continue to modify the nature of our forests through anthropogenic fire, fire suppression, and resource exploitation and management. Past disturbance histories, as well as current cultural practices and ecological processes, must be considered in...
Temporal changes to fire risk in dissimilar WUI communities
N. C. Leyshon; C. A. Dicus; D. B. Sapsis
2015-01-01
Despite increasing proportions of governmental budgets allocated to fire suppression resources, wildfires annually destroy great numbers of homes and critical infrastructure in the wildland-urban interface (WUI). Since 2002, the largest fires in the histories of California, Arizona, Colorado, New Mexico, Utah, Oregon, and Texas have occurred in spite of increased fire...
VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITEWIDE ...
VIEW OF THE DISPATCH OFFICE IN BUILDING 331. ALL SITE-WIDE FIRE ALARM SIGNALS, INCLUDING ALL FIRE PHONES, FIRE PULL BOXES, HEAT AND SMOKE DETECTORS, AND SUPPRESSION SYSTEM FLOW ALARMS, ARE TRANSMITTED TO THE BUILDING 331 DISPATCHER'S OFFICE. (3/77) - Rocky Flats Plant, Vehicle Maintenance Garage & Fire Station, Golden, Jefferson County, CO
Organizational learning contributes to guidance for managing wildland fires for multiple objectives
Tom Zimmerman; Tim Sexton
2010-01-01
Since the inception of organized fire suppression in the early 1900s, wildland fire management has dramatically evolved in operational complexity; ecological significance; social, economic, and political magnitude; areas and timing of application; and recognition of potentially serious consequences. Throughout the past 100 years, fire management has matured from a...