Nucleic acid-coupled colorimetric analyte detectors
Charych, Deborah H.; Jonas, Ulrich
2001-01-01
The present invention relates to methods and compositions for the direct detection of analytes and membrane conformational changes through the detection of color changes in biopolymeric materials. In particular, the present invention provide for the direct colorimetric detection of analytes using nucleic acid ligands at surfaces of polydiacetylene liposomes and related molecular layer systems.
ERIC Educational Resources Information Center
Koesdjojo, Myra T.; Pengpumkiat, Sumate; Wu, Yuanyuan; Boonloed, Anukul; Huynh, Daniel; Remcho, Thomas P.; Remcho, Vincent T.
2015-01-01
We have developed a simple and direct method to fabricate paper-based microfluidic devices that can be used for a wide range of colorimetric assay applications. With these devices, assays can be performed within minutes to allow for quantitative colorimetric analysis by use of a widely accessible iPhone camera and an RGB color reader application…
Emergency First Responders' Experience with Colorimetric Detection Methods
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sandra L. Fox; Keith A. Daum; Carla J. Miller
2007-10-01
Nationwide, first responders from state and federal support teams respond to hazardous materials incidents, industrial chemical spills, and potential weapons of mass destruction (WMD) attacks. Although first responders have sophisticated chemical, biological, radiological, and explosive detectors available for assessment of the incident scene, simple colorimetric detectors have a role in response actions. The large number of colorimetric chemical detection methods available on the market can make the selection of the proper methods difficult. Although each detector has unique aspects to provide qualitative or quantitative data about the unknown chemicals present, not all detectors provide consistent, accurate, and reliable results. Includedmore » here, in a consumer-report-style format, we provide “boots on the ground” information directly from first responders about how well colorimetric chemical detection methods meet their needs in the field and how they procure these methods.« less
Rapid colorimetric sensing of tetracycline antibiotics with in situ growth of gold nanoparticles.
Shen, Li; Chen, Jing; Li, Na; He, Pingli; Li, Zhen
2014-08-11
A colorimetric assay utilizing the formation of gold nanoparticles was developed to detect tetracycline antibiotics in fluidic samples. Tetracycline antibiotics showed the capability of directly reducing aurate salts into atomic gold which form gold nanoparticles spontaneously under proper conditions. The resulted gold nanoparticles showed characteristic plasmon absorbance at 526 nm, which can be visualized by naked eyes or with a spectrophotometer. UV-vis absorbance of the resulted gold nanoparticles is correlated directly with the concentrations of tetracycline antibiotics in the solution, allowing for quantitative colorimetric detection of tetracycline antibiotics. Reaction conditions, such as pH, temperature, reaction time, and ionic strength were optimized. Sensitivity of the colorimetric assay can be enhanced by the addition of gold nanoparticle seeds, a LOD as low as 20 ng mL(-1) can be achieved with the help of seed particles. The colorimetric assay showed minimum interference from ethanol, methanol, urea, glucose, and other antibiotics such as sulfonamides, amino glycosides etc. Validity of the method was also evaluated on urine samples spiked with tetracycline antibiotics. The method provides a broad spectrum detection method for rapid and sensitive detection of reductive substances such as tetracycline antibiotics in liquid and biological samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Reverse phase protein microarrays: fluorometric and colorimetric detection.
Gallagher, Rosa I; Silvestri, Alessandra; Petricoin, Emanuel F; Liotta, Lance A; Espina, Virginia
2011-01-01
The Reverse Phase Protein Microarray (RPMA) is an array platform used to quantitate proteins and their posttranslationally modified forms. RPMAs are applicable for profiling key cellular signaling pathways and protein networks, allowing direct comparison of the activation state of proteins from multiple samples within the same array. The RPMA format consists of proteins immobilized directly on a nitrocellulose substratum. The analyte is subsequently probed with a primary antibody and a series of reagents for signal amplification and detection. Due to the diversity, low concentration, and large dynamic range of protein analytes, RPMAs require stringent signal amplification methods, high quality image acquisition, and software capable of precisely analyzing spot intensities on an array. Microarray detection strategies can be either fluorescent or colorimetric. The choice of a detection system depends on (a) the expected analyte concentration, (b) type of microarray imaging system, and (c) type of sample. The focus of this chapter is to describe RPMA detection and imaging using fluorescent and colorimetric (diaminobenzidine (DAB)) methods.
New method for the direct determination of dissolved Fe(III) concentration in acid mine waters
To, T.B.; Nordstrom, D. Kirk; Cunningham, K.M.; Ball, J.W.; McCleskey, R. Blaine
1999-01-01
A new method for direct determination of dissolved Fe(III) in acid mine water has been developed. In most present methods, Fe(III) is determined by computing the difference between total dissolved Fe and dissolved Fe(II). For acid mine waters, frequently Fe(II) >> Fe(III); thus, accuracy and precision are considerably improved by determining Fe(III) concentration directly. The new method utilizes two selective ligands to stabilize Fe(III) and Fe(II), thereby preventing changes in Fe reduction-oxidation distribution. Complexed Fe(II) is cleanly removed using a silica-based, reversed-phase adsorbent, yielding excellent isolation of the Fe(III) complex. Iron(III) concentration is measured colorimetrically or by graphite furnace atomic absorption spectrometry (GFAAS). The method requires inexpensive commercial reagents and simple procedures that can be used in the field. Calcium(II), Ni(II), Pb(II), AI(III), Zn(II), and Cd(II) cause insignificant colorimetric interferences for most acid mine waters. Waters containing >20 mg of Cu/L could cause a colorimetric interference and should be measured by GFAAS. Cobalt(II) and Cr(III) interfere if their molar ratios to Fe(III) exceed 24 and 5, respectively. Iron(II) interferes when its concentration exceeds the capacity of the complexing ligand (14 mg/L). Because of the GFAAS elemental specificity, only Fe(II) is a potential interferent in the GFAAS technique. The method detection limit is 2 ??g/L (40 nM) using GFAAS and 20 ??g/L (0.4 ??M) by colorimetry.A new method for direct determination of dissolved Fe(III) in acid mine water has been developed. In most present methods, Fe(III) is determined by computing the difference between total dissolved Fe and dissolved Fe(II). For acid mine waters, frequently Fe(II)???Fe(III); thus, accuracy and precision are considerably improved by determining Fe(III) concentration directly. The new method utilizes two selective ligands to stabilize Fe(III) and Fe(II), thereby preventing changes in Fe reduction-oxidation distribution. Complexed Fe(II) is cleanly removed using a silica-based, reversed-phase adsorbent, yielding excellent isolation of the Fe(III) complex. Iron(III) concentration is measured colorimetrically or by graphite furnace atomic absorption spectrometry (GFAAS). The method requires inexpensive commercial reagents and simple procedures that can be used in the field. Calcium(II), Ni(II), Pb(II), Al(III), Zn(II), and Cd(II) cause insignificant colorimetric interferences for most acid mine waters. Waters containing >20 mg of Cu/L could cause a colorimetric interference and should be measured by GFAAS. Cobalt(II) and Cr(III) interfere if their molar ratios to Fe(III) exceed 24 and 5, respectively. Iron(II) interferes when its concentration exceeds the capacity of the complexing ligand (14 mg/L). Because of the GFAAS elemental specificity, only Fe(II) is a potential interferent in the GFAAS technique. The method detection limit is 2/??g/L (40 nM) using GFAAS and 20 ??g/L (0.4 ??M) by colorimetry.
Sol-Gel Matrices For Direct Colorimetric Detection Of Analytes
Charych, Deborah H.; Sasaki, Darryl; Yamanaka, Stacey
2002-11-26
The present invention relates to methods and compositions for the direct detection of analytes using color changes that occur in immobilized biopolymeric material in response to selective binding of analytes to their surface. In particular, the present invention provides methods and compositions related to the encapsulation of biopolymeric material into metal oxide glass using the sol-gel method.
Sol-gel matrices for direct colorimetric detection of analytes
Charych, Deborah H.; Sasaki, Darryl; Yamanaka, Stacey
2000-01-01
The present invention relates to methods and compositions for the direct detection of analytes using color changes that occur in immobilized biopolymeric material in response to selective binding of analytes to their surface. In particular, the present invention provides methods and compositions related to the encapsulation of biopolymeric material into metal oxide glass using the sol-gel method.
Construction of mathematical model for measuring material concentration by colorimetric method
NASA Astrophysics Data System (ADS)
Liu, Bing; Gao, Lingceng; Yu, Kairong; Tan, Xianghua
2018-06-01
This paper use the method of multiple linear regression to discuss the data of C problem of mathematical modeling in 2017. First, we have established a regression model for the concentration of 5 substances. But only the regression model of the substance concentration of urea in milk can pass through the significance test. The regression model established by the second sets of data can pass the significance test. But this model exists serious multicollinearity. We have improved the model by principal component analysis. The improved model is used to control the system so that it is possible to measure the concentration of material by direct colorimetric method.
Wang, Ying; Zhu, Yingjing; Binyam, Atsebeha; Liu, Misha; Wu, Yinan; Li, Fengting
2016-12-15
A label-free sensing strategy based on the enzyme-mimicking activity of MOF was demonstrated for colorimetric detection of biomolecules. Firstly obvious blue color was observed due to the high efficiency of peroxidase-like catalytic activity of Fe-MIL-88A (an ion-based MOF material) toward 3,3',5,5'-tetramethylbenzidine (TMB). Then in the presence of target biomolecule and corresponding aptamer, the mimetic activity of Fe-MIL-88A can be strongly inhibited and used directly to realize the colorimetric detection. On the basis of the interesting findings, we designed a straightforward, label-free and sensitive colorimetric method for biomolecule detection by using the enzyme mimetic property of MOF coupling with molecular recognition element. Compared with the existed publications, our work breaks the routine way by setting up an inorganic-organic MOF-aptamer hybrid platform for colorimetric determination of biomolecules, expanding the targets scope from H2O2 or glucose to biomolecules. As a proof of concept, thrombin and thrombin aptamer was used as a model analyte. The limit of detection of 10nM can be achieved with naked eyes and ultrahigh selectivity of thrombin toward numerous interfering substances with 10-fold concentration was demonstrated significantly. Of note, the method was further applied for the detection of thrombin in human serum samples, showing the results in agreement with those values obtained in an immobilization buffer by the colorimetric method. This inorganic-organic MOF-aptamer sensing strategy may in principle be universally applicable for the detection of a range of environmental or biomedical molecules of interests. Copyright © 2016 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Ragab, Gamal H.; Amin, Alaa S.
2004-03-01
Three accurate, rapid and simple atomic absorption spectrometric, conductometric and colorimetric methods were developed for the determination of norfloxacin (NRF), ciprofloxacin (CIP), ofloxacin (OFL) and enrofloxacin (ENF). The proposed methods depend upon the reaction of ammonium reineckate with the studied drugs to form stable precipitate of ion-pair complexes, which was dissolved in acetone. The pink coloured complexes were determined either by AAS or colorimetrically at λmax 525 nm directly using the dissolved complex. Using conductometric titration, the studied drugs could be evaluated in 50% (v/v) acetone in the range 5.0-65, 4.0-48, 5.0-56 and 6.0-72 μg ml -1 of NRF, CPF, OFL and ENF, respectively. The optimizations of various experimental conditions were described. The results obtained showed good recoveries of 99.15±1.15, 99.30±1.40, 99.60±1.50, and 99.00±1.25% with relative standard deviations of 0.81, 1.06, 0.97, and 0.69% for NRF, CPF, OFL, and ENF, respectively. Applications of the proposed methods to representative pharmaceutical formulations are successfully presented.
Polymeric assay film for direct colorimetric detection
Charych, Deborah; Nagy, Jon; Spevak, Wayne
2002-01-01
A lipid bilayer with affinity to an analyte, which directly signals binding by a changes in the light absorption spectra. This novel assay means and method has special applications in the drug development and medical testing fields. Using a spectrometer, the system is easily automated, and a multiple well embodiment allows inexpensive screening and sequential testing. This invention also has applications in industry for feedstock and effluent monitoring.
Polymeric assay film for direct colorimetric detection
Charych, Deborah; Nagy, Jon; Spevak, Wayne
1999-01-01
A lipid bilayer with affinity to an analyte, which directly signals binding by a changes in the light absorption spectra. This novel assay means and method has special applications in the drug development and medical testing fields. Using a spectrometer, the system is easily automated, and a multiple well embodiment allows inexpensive screening and sequential testing. This invention also has applications in industry for feedstock and effluent monitoring.
A new rhodamine-based colorimetric chemosensor for naked-eye detection of Cu2 + in aqueous solution
NASA Astrophysics Data System (ADS)
Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-li
2016-03-01
A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu2 +. The optical feature of 1 for Cu2 + was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu2 +, the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu2 + complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu2 + with high sensitivity.
NASA Astrophysics Data System (ADS)
Zhang, Aiqin; Yang, Yamin; Zhai, Guangmei; Jia, Husheng; Xu, Bingshe
2016-02-01
In this work, a method of tuning the chromaticity of the emission color of the copolymers containing Eu(III), Tb(III), Be(II) ions based on colorimetric principle was proposed. The technological route from coordination to copolymerization was employed to obtain the white light macromolecular phosphor. The three primary color monomers have been synthesized and their Commission Internationale de L'Eclairage (CIE) coordinates are respectively (0.540, 0.314), (0.231, 0.463), and (0.161, 0.054). The molar feed ratios of the three primary color monomers were calculated from the CIE coordinates based on colorimetric principle. Serial copolymers have been synthesized by free radical copolymerization of the three primary color monomers and methyl methacrylate. The quantum efficiency of the copolymers was higher than that of the complex monomers. The complexes were directly boned to the polymer chain, in which the energy transfer was reduced significantly compared to the doped-polymers. The experimental values of copolymers' CIE coordinates were located in the white light region in good agreement with theoretical values. The results indicate that the chromaticity of the emission color of the copolymers containing Eu(III), Tb(III), Be(II) ions could be tuned by theoretical calculation based on colorimetric principle.
Zhang, Zhiyang; Wang, Han; Chen, Zhaopeng; Wang, Xiaoyan; Choo, Jaebum; Chen, Lingxin
2018-08-30
Plasmonic colorimetric sensors have emerged as a powerful tool in chemical and biological sensing applications due to the localized surface plasmon resonance (LSPR) extinction in the visible range. Among the plasmonic sensors, the most famous sensing mode is the "aggregation" plasmonic colorimetric sensor which is based on plasmon coupling due to nanoparticle aggregation. Herein, this review focuses on the newly-developing plasmonic colorimetric sensing mode - the etching or the growth of metal nanoparticles induces plasmon changes, namely, "non-aggregation" plasmonic colorimetric sensor. This type of sensors has attracted increasing interest because of their exciting properties of high sensitivity, multi-color changes, and applicability to make a test strip. Of particular interest, the test strip by immobilization of nanoparticles on the substrate can avoid the influence of nanoparticle auto-aggregation and increase the simplicity in storage and use. Although there are many excellent reviews available that describe the advance of plasmonic sensors, limited attention has been paid to the plasmonic colorimetric sensors based on etching or growth of metal nanoparticles. This review highlights recent progress on strategies and application of "non-aggregation" plasmonic colorimetric sensors. We also provide some personal insights into current challenges associated with "non-aggregation" plasmonic colorimetric sensors and propose future research directions. Copyright © 2018 Elsevier B.V. All rights reserved.
Accuracy of Blood Loss Measurement during Cesarean Delivery.
Doctorvaladan, Sahar V; Jelks, Andrea T; Hsieh, Eric W; Thurer, Robert L; Zakowski, Mark I; Lagrew, David C
2017-04-01
Objective This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood loss determined by a novel colorimetric system. Agreement between the reference assay and other measures was evaluated by the Bland-Altman method. Results Compared with the blood loss measured by the reference assay (470 ± 296 mL), the colorimetric system (572 ± 334 mL) was more accurate than either visual estimation (928 ± 261 mL) or gravimetric measurement (822 ± 489 mL). The correlation between the assay method and the colorimetric system was more predictive (standardized coefficient = 0.951, adjusted R 2 = 0.902) than either visual estimation (standardized coefficient = 0.700, adjusted R 2 = 00.479) or the gravimetric determination (standardized coefficient = 0.564, adjusted R 2 = 0.304). Conclusion During cesarean delivery, measuring blood loss using colorimetric image analysis is superior to visual estimation and a gravimetric method. Implementation of colorimetric analysis may enhance the ability of management protocols to improve clinical outcomes.
Accuracy of Blood Loss Measurement during Cesarean Delivery
Doctorvaladan, Sahar V.; Jelks, Andrea T.; Hsieh, Eric W.; Thurer, Robert L.; Zakowski, Mark I.; Lagrew, David C.
2017-01-01
Objective This study aims to compare the accuracy of visual, quantitative gravimetric, and colorimetric methods used to determine blood loss during cesarean delivery procedures employing a hemoglobin extraction assay as the reference standard. Study Design In 50 patients having cesarean deliveries blood loss determined by assays of hemoglobin content on surgical sponges and in suction canisters was compared with obstetricians' visual estimates, a quantitative gravimetric method, and the blood loss determined by a novel colorimetric system. Agreement between the reference assay and other measures was evaluated by the Bland–Altman method. Results Compared with the blood loss measured by the reference assay (470 ± 296 mL), the colorimetric system (572 ± 334 mL) was more accurate than either visual estimation (928 ± 261 mL) or gravimetric measurement (822 ± 489 mL). The correlation between the assay method and the colorimetric system was more predictive (standardized coefficient = 0.951, adjusted R2 = 0.902) than either visual estimation (standardized coefficient = 0.700, adjusted R2 = 00.479) or the gravimetric determination (standardized coefficient = 0.564, adjusted R2 = 0.304). Conclusion During cesarean delivery, measuring blood loss using colorimetric image analysis is superior to visual estimation and a gravimetric method. Implementation of colorimetric analysis may enhance the ability of management protocols to improve clinical outcomes. PMID:28497007
Enhanced DNA Sensing via Catalytic Aggregation of Gold Nanoparticles
Huttanus, Herbert M.; Graugnard, Elton; Yurke, Bernard; Knowlton, William B.; Kuang, Wan; Hughes, William L.; Lee, Jeunghoon
2014-01-01
A catalytic colorimetric detection scheme that incorporates a DNA-based hybridization chain reaction into gold nanoparticles was designed and tested. While direct aggregation forms an inter-particle linkage from only ones target DNA strand, the catalytic aggregation forms multiple linkages from a single target DNA strand. Gold nanoparticles were functionalized with thiol-modified DNA strands capable of undergoing hybridization chain reactions. The changes in their absorption spectra were measured at different times and target concentrations and compared against direct aggregation. Catalytic aggregation showed a multifold increase in sensitivity at low target concentrations when compared to direct aggregation. Gel electrophoresis was performed to compare DNA hybridization reactions in catalytic and direct aggregation schemes, and the product formation was confirmed in the catalytic aggregation scheme at low levels of target concentrations. The catalytic aggregation scheme also showed high target specificity. This application of a DNA reaction network to gold nanoparticle-based colorimetric detection enables highly-sensitive, field-deployable, colorimetric readout systems capable of detecting a variety of biomolecules. PMID:23891867
Kangas, Michael J; Burks, Raychelle M; Atwater, Jordyn; Lukowicz, Rachel M; Garver, Billy; Holmes, Andrea E
2018-02-01
With the increasing availability of digital imaging devices, colorimetric sensor arrays are rapidly becoming a simple, yet effective tool for the identification and quantification of various analytes. Colorimetric arrays utilize colorimetric data from many colorimetric sensors, with the multidimensional nature of the resulting data necessitating the use of chemometric analysis. Herein, an 8 sensor colorimetric array was used to analyze select acid and basic samples (0.5 - 10 M) to determine which chemometric methods are best suited for classification quantification of analytes within clusters. PCA, HCA, and LDA were used to visualize the data set. All three methods showed well-separated clusters for each of the acid or base analytes and moderate separation between analyte concentrations, indicating that the sensor array can be used to identify and quantify samples. Furthermore, PCA could be used to determine which sensors showed the most effective analyte identification. LDA, KNN, and HQI were used for identification of analyte and concentration. HQI and KNN could be used to correctly identify the analytes in all cases, while LDA correctly identified 95 of 96 analytes correctly. Additional studies demonstrated that controlling for solvent and image effects was unnecessary for all chemometric methods utilized in this study.
Leng, Pei-Qiang; Zhao, Feng-Lan; Yin, Bin-Cheng; Ye, Bang-Ce
2015-05-21
We developed a novel colorimetric method for rapid detection of biogenic amines based on arylalkylamine N-acetyltransferase (aaNAT). The proposed method offers distinct advantages including simple handling, high speed, low cost, good sensitivity and selectivity.
Hu, Yang; Zhang, Jing; Lv, Yuan-Zheng; Huang, Xiao-Huan; Hu, Sheng-Li
2016-03-15
A new colorimetric probe 1 based on rhodamine B lactam was developed for naked-eye detection of Cu(2+). The optical feature of 1 for Cu(2+) was investigated by UV-vis absorption spectroscopy. Upon the addition of Cu(2+), the 1 displayed a distinct color change from colorless to pink, which can be directly detected by the naked eye. The stoichiometry of 1 to Cu(2+) complex was found to be 1:1 and the naked-eye detection limit was determined as low as 2 μM. The results suggest that the probe 1 may provide a convenient method for visual detection of Cu(2+) with high sensitivity. Copyright © 2015 Elsevier B.V. All rights reserved.
Three dimensional colorimetric assay assemblies
DOE Office of Scientific and Technical Information (OSTI.GOV)
Charych, D.; Reichart, A.
2000-06-27
A direct assay is described using novel three-dimensional polymeric assemblies which change from a blue to red color when exposed to an analyte, in one case a flu virus. The assemblies are typically in the form of liposomes which can be maintained in a suspension, and show great intensity in their color changes. Their method of production is also described.
Determination of methadone hydrochloride in a maintenance dosage formulation.
Hoffmann, T J; Thompson, R D
1975-07-01
A colorimetric method for direct quantitative assay of methadone hydrochloride in liquid oral dosage forms is presented. The procedure involves the formation of a dye complex with bromothymol blue buffer solution. The resultant complex is extracted with benzene and measured spectrophotometrically. Duplicate tests on the formulation showed 99.2% of the labeled amount of methadone.
Three dimensional colorimetric assay assemblies
Charych, Deborah; Reichart, Anke
2000-01-01
A direct assay is described using novel three-dimensional polymeric assemblies which change from a blue to red color when exposed to an analyte, in one case a flu virus. The assemblies are typically in the form of liposomes which can be maintained in a suspension, and show great intensity in their color changes. Their method of production is also described.
Three-dimensional colorimetric assay assemblies
Charych, Deborah; Reichert, Anke
2001-01-01
A direct assay is described using novel three-dimensional polymeric assemblies which change from a blue to red color when exposed to an analyte, in one case a flue virus. The assemblies are typically in the form of liposomes which can be maintained in a suspension, and show great intensity in their color changes. Their method of production is also described.
Comparison of macro-gravimetric and micro-colorimetric lipid determination methods.
Inouye, Laura S; Lotufo, Guiherme R
2006-10-15
In order to validate a method for lipid analysis of small tissue samples, the standard macro-gravimetric method of Bligh-Dyer (1959) [E.G. Bligh, W.J. Dyer, Can. J. Biochem. Physiol. 37 (1959) 911] and a modification of the micro-colorimetric assay developed by Van Handel (1985) [E. Van Handel, J. Am. Mosq. Control Assoc. 1 (1985) 302] were compared. No significant differences were observed for wet tissues of two species of fish. However, limited analysis of wet tissue of the amphipod, Leptocheirusplumulosus, indicated that the Bligh-Dyer gravimetric method generated higher lipid values, most likely due to the inclusion of non-lipid materials. Additionally, significant differences between the methods were observed with dry tissues, with the micro-colorimetric method consistently reporting calculated lipid values greater than as reported by the gravimetric method. This was most likely due to poor extraction of dry tissue in the standard Bligh-Dyer method, as no significant differences were found when analyzing a single composite extract. The data presented supports the conclusion that the micro-colorimetric method described in this paper is accurate, rapid, and minimizes time and solvent use.
Infrared and colorimetric characterization of discolored kiln-dried hard maple lumber
Benjamin E. Dawson-Andoh; Michael Wiemann; Laurent Matuana; John Baumgras
2004-01-01
Discoloration of hard maple lumber commonly occurs during kiln-drying. In this study, discolored andnondiscolored kiln-dried hard maple lumber boards were characterized using a colorimetric method and Attenuated Total Reflectance-Fourier Transform Infrared Spectroscopy (ATR-FTIR). Colorimetric measurements (L*, a*, b*) were found to be in good agreement with visual...
Arnaud, J; Chappuis, P; Zawislak, R; Houot, O; Jaudon, M C; Bienvenu, F; Bureau, F
1993-02-01
An interlaboratory collaborative trial was conducted on the determination of serum copper using two different methods, based on colorimetry (test combination Copper, Boehringer Mannheim, Mannheim, Germany) and flame atomic absorption spectrometry (FAAS). The general performance of the colorimetric method was below that of FAAS, except for sensitivity and linear range, as assessed by detection limit (0.44 versus 1.32 mumol/L) and upper limit of linearity (150 versus 50 mumol/L). The range of the between-run CVs and the recovery of standard additions were, respectively, 2.3-11.9% and 92-127% for the colorimetric method and 1.1-6.0% and 93-101% for the FAAS method. Interferences were minimal with both methods. The two techniques correlated satisfactorily (the correlation coefficients ranged from 0.945-0.970 among laboratories) but the colorimetric assay exhibited slightly higher results than the FAAS method. Each method was transferable among laboratories.
Amirjani, Amirmostafa; Fatmehsari, Davoud Haghshenas
2018-01-01
In this work, a rapid and straightforward method was developed for colorimetric determination of ammonia using smartphones. The mechanisms is based on the manipulation of the surface plasmon band of silver nanoparticles (AgNPs) via the formation of Ag (NH 3 ) 2 + complex. This complex decreases the amount of AgNPs in the solution and consequently, the color intensity of the colloidal system decreases. Not only the variation in color intensity of the solution can be tracked by a UV-vis spectrophotometer, but also a smartphone can be employed to monitor the color intensity variation by RGB analysis. Ammonia, in the concentration range of 10-1000mgL -1 , was successfully measured spectrophotometrically (UV-vis spectrophotometer) and colorimetrically (RGB measurement) with the detection limit of 180 and 200mgL -1 , respectively. Linear relationships were also developed for both methods. Also, the response time of the developed colorimetric sensor was around 20s. Both of the colorimetric and spectrophotometric methods showed a reliable performance for determination of ammonia in the real samples. Copyright © 2017 Elsevier B.V. All rights reserved.
An Illumination-Adaptive Colorimetric Measurement Using Color Image Sensor
NASA Astrophysics Data System (ADS)
Lee, Sung-Hak; Lee, Jong-Hyub; Sohng, Kyu-Ik
An image sensor for a use of colorimeter is characterized based on the CIE standard colorimetric observer. We use the method of least squares to derive a colorimetric characterization matrix between RGB output signals and CIE XYZ tristimulus values. This paper proposes an adaptive measuring method to obtain the chromaticity of colored scenes and illumination through a 3×3 camera transfer matrix under a certain illuminant. Camera RGB outputs, sensor status values, and photoelectric characteristic are used to obtain the chromaticity. Experimental results show that the proposed method is valid in the measuring performance.
NASA Astrophysics Data System (ADS)
Dittrich, Paul-Gerald; Grunert, Fred; Ehehalt, Jörg; Hofmann, Dietrich
2015-03-01
Aim of the paper is to show that the colorimetric characterization of optically clear colored liquids can be performed with different measurement methods and their application specific multichannel spectral sensors. The possible measurement methods are differentiated by the applied types of multichannel spectral sensors and therefore by their spectral resolution, measurement speed, measurement accuracy and measurement costs. The paper describes how different types of multichannel spectral sensors are calibrated with different types of calibration methods and how the measurement values can be used for further colorimetric calculations. The different measurement methods and the different application specific calibration methods will be explained methodically and theoretically. The paper proofs that and how different multichannel spectral sensor modules with different calibration methods can be applied with smartpads for the calculation of measurement results both in laboratory and in field. A given practical example is the application of different multichannel spectral sensors for the colorimetric characterization of petroleum oils and fuels and their colorimetric characterization by the Saybolt color scale.
A new cation-exchange method for accurate field speciation of hexavalent chromium
Ball, J.W.; McCleskey, R. Blaine
2003-01-01
A new method for field speciation of Cr(VI) has been developed to meet present stringent regulatory standards and to overcome the limitations of existing methods. The method consists of passing a water sample through strong acid cation-exchange resin at the field site, where Cr(III) is retained while Cr(VI) passes into the effluent and is preserved for later determination. The method is simple, rapid, portable, and accurate, and makes use of readily available, inexpensive materials. Cr(VI) concentrations are determined later in the laboratory using any elemental analysis instrument sufficiently sensitive to measure the Cr(VI) concentrations of interest. The new method allows measurement of Cr(VI) concentrations as low as 0.05 ??g 1-1, storage of samples for at least several weeks prior to analysis, and use of readily available analytical instrumentation. Cr(VI) can be separated from Cr(III) between pH 2 and 11 at Cr(III)/Cr(VI) concentration ratios as high as 1000. The new method has demonstrated excellent comparability with two commonly used methods, the Hach Company direct colorimetric method and USEPA method 218.6. The new method is superior to the Hach direct colorimetric method owing to its relative sensitivity and simplicity. The new method is superior to USEPA method 218.6 in the presence of Fe(II) concentrations up to 1 mg 1-1 and Fe(III) concentrations up to 10 mg 1-1. Time stability of preserved samples is a significant advantage over the 24-h time constraint specified for USEPA method 218.6.
NASA Astrophysics Data System (ADS)
Marsella, Alessandra; Valentini, Paola; Tarantino, Paolo; Congedo, Maurizio; Pompa, Pier Paolo
2016-04-01
We report a simple, rapid and low-cost test, based on gold nanoparticles, for the naked-eye colorimetric detection of a signature of single nucleotide polymorphisms (SNPs) relevant for the personalized medicine of psoriasis patients. We validated the colorimetric assay on real-world DNA samples from a cohort of 30 psoriasis patients and we compared the results, in double-blind, with those obtained with two state-of-the-art instrumental techniques, namely reverse dot blotting and direct sequencing, finding 100% agreement. We demonstrated high accuracy, sensitivity and specificity of the colorimetric test that can be easily adapted for the genotypization of different SNPs, important for the pharmacogenomics of various diseases, and in other fields, such as food traceability and population structure analysis.
Needle Decompression of Tension Pneumothorax with Colorimetric Capnography.
Naik, Nimesh D; Hernandez, Matthew C; Anderson, Jeff R; Ross, Erika K; Zielinski, Martin D; Aho, Johnathon M
2017-11-01
The success of needle decompression for tension pneumothorax is variable, and there are no objective measures assessing effective decompression. Colorimetric capnography, which detects carbon dioxide present within the pleural space, may serve as a simple test to assess effective needle decompression. Three swine underwent traumatically induced tension pneumothorax (standard of care, n = 15; standard of care with needle capnography, n = 15). Needle thoracostomy was performed with an 8-cm angiocatheter. Similarly, decompression was performed with the addition of colorimetric capnography. Subjective operator assessment of decompression was recorded and compared with true decompression, using thoracoscopic visualization for both techniques. Areas under receiver operating curves were calculated and pairwise comparison was performed to assess statistical significance (P < .05). The detection of decompression by needle colorimetric capnography was found to be 100% accurate (15 of 15 attempts), when compared with thoracoscopic assessment (true decompression). Furthermore, it accurately detected the lack of tension pneumothorax, that is, the absence of any pathologic/space-occupying lesion, in 100% of cases (10 of 10 attempts). Standard of care needle decompression was detected by operators in 9 of 15 attempts (60%) and was detected in 3 of 10 attempts when tension pneumothorax was not present (30%). True decompression, under direct visualization with thoracoscopy, occurred 15 of 15 times (100%) with capnography, and 12 of 15 times (80%) without capnography. Areas under receiver operating curves were 0.65 for standard of care and 1.0 for needle capnography (P = .002). Needle decompression with colorimetric capnography provides a rapid, effective, and highly accurate method for eliminating operator bias for tension pneumothorax decompression. This may be useful for the treatment of this life-threatening condition. Copyright © 2017 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.
Two common laboratory extraction techniques were evaluated for routine use with the micro-colorimetric lipid determination method developed by Van Handel (1985) [E. Van Handel, J. Am. Mosq. Control Assoc. 1(1985) 302] and recently validated for small samples by Inouye and Lotufo ...
NASA Astrophysics Data System (ADS)
Fang, Jingyu; Xu, Haisong; Wang, Zhehong; Wu, Xiaomin
2016-05-01
With colorimetric characterization, digital cameras can be used as image-based tristimulus colorimeters for color communication. In order to overcome the restriction of fixed capture settings adopted in the conventional colorimetric characterization procedures, a novel method was proposed considering capture settings. The method calculating colorimetric value of the measured image contains five main steps, including conversion from RGB values to equivalent ones of training settings through factors based on imaging system model so as to build the bridge between different settings, scaling factors involved in preparation steps for transformation mapping to avoid errors resulted from nonlinearity of polynomial mapping for different ranges of illumination levels. The experiment results indicate that the prediction error of the proposed method, which was measured by CIELAB color difference formula, reaches less than 2 CIELAB units under different illumination levels and different correlated color temperatures. This prediction accuracy for different capture settings remains the same level as the conventional method for particular lighting condition.
Basic methods for measuring the reflectance color of iron oxides
NASA Astrophysics Data System (ADS)
Pospisil, Jaroslav; Hrdy, Jan; Hrdy Jan, Jr.
2007-06-01
The main contribution of the present article consists in coherent description and interpretation of the principles of basic measuring methods and colorimeters for color classification and evaluation of light reflecting samples containing iron oxides. The chosen relevant theoretical background is based on the CIE tristimulus colorimetric system (X,Y,Z), the CIE colorimetric system (L*,a*,b*) and the Munsell colorimetric system (H,V,C). As an example of color identification and evaluation, some specific mathematical and graphical relationships between the soil redness rate and the corresponding hematite content are shown.
Honeyfield, D.C.; Hanes, J.W.; Brown, L.; Kraft, C.E.; Begley, T.P.
2010-01-01
Thiaminase induced thiamine deficiency occurs in fish, humans, livestock and wild animals. A non-radioactive thiaminase assay was described in 2007, but a direct comparison with the radioactive 14C-thiamine method which has been in use for more than 30years has not been reported. The objective was to measure thiaminase activity in forage fish (alewife Alosa pseudoharengus, rainbow smelt Osmerus mordax, and slimy sculpin Cottus cognatus) consumed by predators that manifest thiamine deficiency using both methods. Modifications were made to the colorimetric assay to improve repeatability. Modification included a change in assay pH, enhanced sample clean-up, constant assay temperature (37??C), increase in the concentration of 4-nitrothiophenol (4NTP) and use of a spectrophotometer fitted with a 0.2cm cell. A strong relationship between the two assays was found for 51 alewife (R2=0.85), 36 smelt (R2=0.87) and 20 sculpin (R2=0.82). Thiaminase activity in the colorimetric assay was about 1000 times higher than activity measured by the radioactive method. Application of the assay to fish species from which no thiaminase activity has previously been reported resulted in no 4NTP thiaminase activity being found in bloater Coregonus hoyi, lake trout Salvelinus namaycusch, steelhead trout Oncorhynchus mykiss or Chinook salmon Oncorhynchus tshawytscha. In species previously reported to contain thiaminase, 4NTP thiaminase activity was measured in bacteria Paenibacillus thiaminolyticus, gizzard shad Dorosoma cepedianum, bracken fern Pteridium aquilinum, quagga mussel Dreissena bugensis and zebra mussels D. polymorpha. ?? 2010.
Tsukatani, Tadayuki; Suenaga, Hikaru; Ishiyama, Munetaka; Ezoe, Takatoshi; Matsumoto, Kiyoshi
2011-07-15
A method for the determination of water-soluble vitamins using a colorimetric microbial viability assay based on the reduction of the tetrazolium salt {2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2,4-disulfophenyl)-2H-tetrazolium, monosodium salt (WST-8)} via 2-methyl-1,4-napthoquinone (NQ) was developed. Measurement conditions were optimized for the microbiological determination of water-soluble vitamins, such as vitamin B(6), biotin, folic acid, niacin, and pantothenic acid, using microorganisms that have a water-soluble vitamin requirement. A linear relationship between absorbance and water-soluble vitamin concentration was obtained. The proposed method was applied to determine the concentration of vitamin B(6) in various foodstuffs. There was good agreement between vitamin B(6) concentrations determined after 24h using the WST-8 colorimetric method and those obtained after 48h using a conventional method. The results suggest that the WST-8 colorimetric assay is a useful method for the rapid determination of water-soluble vitamins in a 96-well microtiter plate. Copyright © 2011 Elsevier Ltd. All rights reserved.
Arkhipova, Viktoriya V; Apyari, Vladimir V; Dmitrienko, Stanislava G
2015-03-15
Desensitized ionene-stabilized gold nanoparticles have been prepared and applied as a colorimetric probe for the single-step test for sulfate ions at the relatively high concentration level. The approach is based on aggregation of the nanoparticles leading to the change in absorption spectra and color of the solution. These nanoparticles are characterized by the decreased sensitivity due to both electrostatic and steric stabilization, which allows for simple, and rapid direct single-step determination of sulfate at the relatively high concentration level in real water samples without sample pretreatment or dilution. Influence of different factors (the time of interaction, pH, the concentrations of sulfate ions and the nanoparticles) on the aggregation and analytical performance of the procedure was investigated. The method allows for the determination of sulfate ions in the mass range of 0.2-0.4 mg with RSD of 5% from the sample volume of less than 2 mL. It has a sharp dependence of the colorimetric response on the concentration of sulfate, which makes it prospective for indicating deviations of the sulfate concentration regarding some declared value chosen within the above range. The time of the analysis is 2 min. The method was applied to the analysis of mineral water samples. Copyright © 2014 Elsevier B.V. All rights reserved.
Accelerated Colorimetric Micro-assay for Screening Mold Inhibitors
Carol A. Clausen; Vina W. Yang
2014-01-01
Rapid quantitative laboratory test methods are needed to screen potential antifungal agents. Existing laboratory test methods are relatively time consuming, may require specialized test equipment and rely on subjective visual ratings. A quantitative, colorimetric micro-assay has been developed that uses XTT tetrazolium salt to metabolically assess mold spore...
Wren, J. J.; Wiggall, P. H.
1965-01-01
1. The conditions required for sensitive and specific colorimetric determination of proline with acidified ninhydrin were investigated. 2. A method applicable to protein samples was developed. 3. The only compound found to interfere appreciably was a hydroxyproline. PMID:14342233
Doped colorimetric assay liposomes
Charych, Deborah; Stevens, Raymond C.
2001-01-01
The present invention provides compositions comprising colorimetric assay liposomes. The present invention also provides methods for producing colorimetric liposomes and calorimetric liposome assay systems. In preferred embodiments, these calorimetric liposome systems provide high levels of sensitivity through the use of dopant molecules. As these dopants allow the controlled destabilization of the liposome structure, upon exposure of the doped liposomes to analyte(s) of interest, the indicator color change is facilitated and more easily recognized.
Gong, Rui; Xu, Haisong; Tong, Qingfen
2012-10-20
The colorimetric characterization of active matrix organic light emitting diode (AMOLED) panels suffers from their poor channel independence. Based on the colorimetric characteristics evaluation of channel independence and chromaticity constancy, an accurate colorimetric characterization method, namely, the polynomial compensation model (PC model) considering channel interactions was proposed for AMOLED panels. In this model, polynomial expressions are employed to calculate the relationship between the prediction errors of XYZ tristimulus values and the digital inputs to compensate the XYZ prediction errors of the conventional piecewise linear interpolation assuming the variable chromaticity coordinates (PLVC) model. The experimental results indicated that the proposed PC model outperformed other typical characterization models for the two tested AMOLED smart-phone displays and for the professional liquid crystal display monitor as well.
Multiplexed Colorimetric Solid-Phase Extraction
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.
2009-01-01
Multiplexed colorimetric solid-phase extraction (MC-SPE) is an extension of colorimetric solid-phase extraction (C-SPE) an analytical platform that combines colorimetric reagents, solid phase extraction, and diffuse reflectance spectroscopy to quantify trace analytes in water. In CSPE, analytes are extracted and complexed on the surface of an extraction membrane impregnated with a colorimetric reagent. The analytes are then quantified directly on the membrane surface using a handheld diffuse reflectance spectrophotometer. Importantly, the use of solid-phase extraction membranes as the matrix for impregnation of the colorimetric reagents creates a concentration factor that enables the detection of low concentrations of analytes in small sample volumes. In extending C-SPE to a multiplexed format, a filter holder that incorporates discrete analysis channels and a jig that facilitates the concurrent operation of multiple sample syringes have been designed, enabling the simultaneous determination of multiple analytes. Separate, single analyte membranes, placed in a readout cartridge create unique, analyte-specific addresses at the exit of each channel. Following sample exposure, the diffuse reflectance spectrum of each address is collected serially and the Kubelka-Munk function is used to quantify each water quality parameter via calibration curves. In a demonstration, MC-SPE was used to measure the pH of a sample and quantitate Ag(I) and Ni(II).
Zargar, Behrooz; Hatamie, Amir
2013-04-01
Isoniazid is an important antibiotic, which is widely used to treat tuberculosis. This study presents a colorimetric method for the determination of Isoniazid based on localized surface plasmon resonance (LSPR) property of gold nanoparticles. An LSPR band is produced by reducing gold ions in solution using Isoniazid as the reducing agent. Influences of the following relevant variables were examined and optimized in the experiment, formation time of gold nanoparticles, pH, buffer and stabilizer. These tests demonstrated that under optimum conditions the absorbance of Au nanoparticles at 530 nm related linearly to the concentration of Isoniazid in the range of 1.0-8.0 μg mL(-1) with a detection limit of 0.98 μg mL(-1). This colorimetric method has been successfully applied to the determine Isoniazid in tablets and spiked serum samples. The proposed colorimetric assay exhibits good reproducibility and accuracy, providing a simple and rapid method for analysis of Isoniazid. Copyright © 2013 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Zargar, Behrooz; Hatamie, Amir
2013-04-01
Isoniazid is an important antibiotic, which is widely used to treat tuberculosis. This study presents a colorimetric method for the determination of Isoniazid based on localized surface plasmon resonance (LSPR) property of gold nanoparticles. An LSPR band is produced by reducing gold ions in solution using Isoniazid as the reducing agent. Influences of the following relevant variables were examined and optimized in the experiment, formation time of gold nanoparticles, pH, buffer and stabilizer. These tests demonstrated that under optimum conditions the absorbance of Au nanoparticles at 530 nm related linearly to the concentration of Isoniazid in the range of 1.0-8.0 μg mL-1 with a detection limit of 0.98 μg mL-1. This colorimetric method has been successfully applied to the determine Isoniazid in tablets and spiked serum samples. The proposed colorimetric assay exhibits good reproducibility and accuracy, providing a simple and rapid method for analysis of Isoniazid.
Measurement of Chlorine Dioxide in Water by DPD Colorimetric Method
NASA Astrophysics Data System (ADS)
Song, Min; Yan, Panping; Yao, Jun
2018-01-01
In order to solve the problems of chlorine dioxide in water by DPD colorimetric method, this paper discusses the effects of the formulation, temperature, color development time and amount of color reagent on the measurement process, improving the on-line instrument for domestic and drinking water in chlorine dioxide measurement precision and accuracy.
Colorimetric micro-assay for accelerated screening of mould inhibitors
Carol A. Clausen; Vina W. Yang
2013-01-01
Since current standard laboratory methods are time-consuming macro-assays that rely on subjective visual ratings of mould growth, rapid and quantitative laboratory methods are needed to screen potential mould inhibitors for use in and on cellulose-based products. A colorimetric micro-assay has been developed that uses XTT tetrazolium salt to enzymatically assess...
2014-01-01
Background The quality of routine indoor residual spraying (IRS) operations is rarely assessed because of the limited choice of methods available for quantifying insecticide content in the field. This study, therefore, evaluated a user-friendly, rapid colorimetric assay for detecting insecticide content after routine IRS operations were conducted. Methods This study was conducted in Tafea Province, Vanuatu. Routine IRS was conducted with lambda cyhalothrin. Two methods were used to quantify the IRS activities: 1) pre-spray application of small felt pads and 2) post-spray removal of insecticide with adhesive. The insecticide content was quantified using a colorimetric assay (Insecticide Quantification Kit [IQK]), which involved exposing each sample to the test reagents for 15 mins. The concentration of insecticide was indicated by the depth of red colour. Results The IQK proved simple to perform in the field and results could be immediately interpreted by the programme staff. The insecticide content was successfully sampled by attaching felt pads to the house walls prior to spraying. The IRS operation was well conducted, with 83% of houses being sprayed at the target dose (20 – 30 mg AI/m2). The average reading across all houses was 24.4 ± 1.5 mg AI/m2. The results from the felt pads applied pre-spray were used as a base to compare methods for sampling insecticide from walls post-spray. The adhesive of Sellotape did not collect adequate samples. However, the adhesive of the felt pads provided accurate samples of the insecticide content on walls. Conclusion The IQK colorimetric assay proved to be a useful tool that was simple to use under realistic field conditions. The assay provided rapid information on IRS spray dynamics and spray team performance, facilitating timely decision making and reporting for programme managers. The IQK colorimetric assay will have direct applications for routine quality control in malaria control programmes globally and has the potential to improve the efficacy of vector control operations. PMID:24885084
Redmile-Gordon, M A; Armenise, E; White, R P; Hirsch, P R; Goulding, K W T
2013-12-01
Soil extracts usually contain large quantities of dissolved humified organic material, typically reflected by high polyphenolic content. Since polyphenols seriously confound quantification of extracted protein, minimising this interference is important to ensure measurements are representative. Although the Bradford colorimetric assay is used routinely in soil science for rapid quantification protein in soil-extracts, it has several limitations. We therefore investigated an alternative colorimetric technique based on the Lowry assay (frequently used to measure protein and humic substances as distinct pools in microbial biofilms). The accuracies of both the Bradford assay and a modified Lowry microplate method were compared in factorial combination. Protein was quantified in soil-extracts (extracted with citrate), including standard additions of model protein (BSA) and polyphenol (Sigma H1675-2). Using the Lowry microplate assay described, no interfering effects of citrate were detected even with concentrations up to 5 times greater than are typically used to extract soil protein. Moreover, the Bradford assay was found to be highly susceptible to two simultaneous and confounding artefacts: 1) the colour development due to added protein was greatly inhibited by polyphenol concentration, and 2) substantial colour development was caused directly by the polyphenol addition. In contrast, the Lowry method enabled distinction between colour development from protein and non-protein origin, providing a more accurate quantitative analysis. These results suggest that the modified-Lowry method is a more suitable measure of extract protein (defined by standard equivalents) because it is less confounded by the high polyphenolic content which is so typical of soil extracts.
Kim, Min Soon; Rodney, William N.; Cooper, Tara; Kite, Chris; Reece, Gregory P.; Markey, Mia K.
2011-01-01
Rationale, aims and objectives Scarring is a significant cause of dissatisfaction for women who undergo breast surgery. Scar tissue may be clinically distinguished from normal skin by aberrant color, rough surface texture, increased thickness (hypertrophy), and firmness. Colorimeters or spectrophotometers can be used to quantitatively assess scar color, but they require direct patient interaction and can cost thousands of dollars By comparison, digital photography is already in widespread use to document clinical outcomes and requires less patient interaction. Thus, assessment of scar coloration by digital photography is an attractive alternative. The goal of this study was to compare color measurements obtained by digital photography and colorimetry. Method Agreement between photographic and colorimetric measurements of color were evaluated. Experimental conditions were controlled by performing measurements on artificial scars created by a makeup artist. The colorimetric measurements of the artificial scars were compared to those reported in the literature for real scars in order to confirm the validity of this approach. We assessed the agreement between the colorimetric and photographic measurements of color using a hypothesis test for equivalence, the intra-class correlation coefficient (ICC), and the Bland-Altman method. Results Overall, good agreement was obtained for three parameters (L*a*b*) measured by colorimetry and photography from the results of three statistical analyses. Conclusion Color measurements obtained by digital photography were equivalent to those obtained using colorimetry. Thus, digital photography is a reliable, cost-effective measurement method of skin color and should be further investigated for quantitative analysis of surgical outcomes. PMID:19239578
Zinc Biosorption by Seaweed Illustrated by the Zincon Colorimetric Method and the Langmuir Isotherm
ERIC Educational Resources Information Center
Areco, Maria Mar; dos Santos Afonso, Maria; Valdman, Erika
2007-01-01
An experiment is conducted to promote biotechnology knowledge that is an emerging technology on cleaning treatment, showing the potential of seaweed to remove heavy-metal ions from solution. The rapid and accurate determination of zinc in aqueous solution by the zincon colorimetric method gives an interesting and simple experiment for any…
Colorimetric and fluorescent detection of hydrazine with high sensitivity and excellent selectivity
NASA Astrophysics Data System (ADS)
Shi, Bingjie; Qi, Sujie; Yu, Mingming; Liu, Chunxia; Li, Zhanxian; Wei, Liuhe; Ni, Zhonghai
2018-01-01
It is critical to develop probes for rapid, selective, and sensitive detection of the highly toxic hydrazine in both environmental and biological science. In this work, under mild condition, a novel colorimetric and off-on fluorescent probe was synthesized for rapid recognition of hydrazine with excellent selectivity over other various species including some biological species, metal ions and anions. The limit of quantification (LOQ) value was 1.5 × 10- 4 M-3.2 × 10- 3 M (colorimetric method) and 1.5 × 10- 4 M - 3.2 × 10- 3 M (fluorescent method) with as low as detection limit of 46.2 μM.
Colorimetric determination of cyanide liberated from apricot kernels.
Egli, K L
1977-07-01
A simple colorimetric method is described for determining the quantity of hydrogen cyanide produced by the spontaneous decomposition of amygdalin in apricot kernels. The evolved cyanide is collected in sodium hydroxide solution and assayed colorimetrically by reaction with picric acid. Results for duplicate assays, 3.02 and 3.06 mg CN-/g, compare well with those obtained by AOAC method 26.115 which specifies steam distillation and silver nitrate titration; results for triplicate assays were 3.02, 3.03, and 3.08 mg CN-/g by the latter. Recovery of cyanide from potassium cyanide at a level equivalent to 243 microgram CN-/g was 101.0%.
Colorimetric detection for paper-based biosensing applications
NASA Astrophysics Data System (ADS)
Brink, C.; Joubert, T.-H.
2016-02-01
Research on affordable point-of-care health diagnostics is rapidly advancing1. Colorimetric biosensor applications are typically qualitative, but recently the focus has been shifted to quantitative measurements2,3. Although numerous qualitative point-of-care (POC) health diagnostic devices are available, the challenge exists of developing a quantitative colorimetric array reader system that complies with the ASSURED (Affordable, Sensitive, Specific, User-friendly, Rapid and Robust, Equipment-free, Deliverable to end-users) principles of the World Health Organization4. This paper presents a battery powered 8-bit tonal resolution colorimetric sensor circuit for paper microfluidic assays using low cost photo-detection circuitry and a low-power LED light source. A colorimetric 3×3-pixel array reader was developed for rural environments where resources and personnel are limited. The device sports an ultralow-power E-ink paper display. The colorimetric device includes integrated GPS functionality and EEPROM memory to log measurements with geo-tags for possible analysis of regional trends. The device competes with colour intensity measurement techniques using smartphone cameras, but proves to be a cheaper solution, compensating for the typical performance variations between cameras of different brands of smartphones. Inexpensive methods for quantifying bacterial assays have been shown using desktop scanners, which are not portable, and cameras, which suffer severely from changes in ambient light in different environments. Promising colorimetric detection results have been demonstrated using devices such as video cameras5, digital colour analysers6, flatbed scanners7 or custom portable readers8. The major drawback of most of these methods is the need for specialized instrumentation and for image analysis on a computer.
Garcia, Rafaela Alvim; Vanelli, Chislene Pereira; Pereira Junior, Olavo Dos Santos; Corrêa, José Otávio do Amaral
2018-06-19
Hydroelectrolytic disorders are common in clinical situations and may be harmful to the patient, especially those involving plasma sodium and potassium dosages. Among the possible methods for the dosages are flame photometry, ion-selective electrode (ISE) and colorimetric enzymatic method. We analyzed 175 samples in the three different methods cited from patients attending the laboratory of the University Hospital of the Federal University of Juiz de Fora. The values obtained were statistically treated using SPSS 19.0 software. The present study aims to evaluate the impact of the use of these different methods in the determination of plasma sodium and potassium. The averages obtained for sodium and potassium measurements by flame photometry were similar (P > .05) to the means obtained for the two electrolytes by ISE. The averages obtained by the colorimetric enzymatic method presented statistical difference in relation to ISE, both for sodium and potassium. In the correlation analysis, both flame photometry and colorimetric enzymatic showed a strong correlation with the ISE method for both dosages. At the first time in the same work sodium and potassium were analyzed by three different methods and the results allowed us to conclude that the methods showed a positive and strong correlation, and can be applied in the clinical routine. © 2018 Wiley Periodicals, Inc.
Kim, Min Soon; Rodney, William N; Cooper, Tara; Kite, Chris; Reece, Gregory P; Markey, Mia K
2009-02-01
Scarring is a significant cause of dissatisfaction for women who undergo breast surgery. Scar tissue may be clinically distinguished from normal skin by aberrant colour, rough surface texture, increased thickness (hypertrophy) and firmness. Colorimeters or spectrophotometers can be used to quantitatively assess scar colour, but they require direct patient interaction and can cost thousands of dollars. By comparison, digital photography is already in widespread use to document clinical outcomes and requires less patient interaction. Thus, assessment of scar coloration by digital photography is an attractive alternative. The goal of this study was to compare colour measurements obtained by digital photography and colorimetry. Agreements between photographic and colorimetric measurements of colour were evaluated. Experimental conditions were controlled by performing measurements on artificial scars created by a make-up artist. The colorimetric measurements of the artificial scars were compared with those reported in the literature for real scars in order to confirm the validity of this approach. We assessed the agreement between the colorimetric and photographic measurements of colour using a hypothesis test for equivalence, the intraclass correlation coefficient and the Bland-Altman method. Overall, good agreement was obtained for three parameters (L*a*b*) measured by colorimetry and photography from the results of three statistical analyses. Colour measurements obtained by digital photography were equivalent to those obtained using colorimetry. Thus, digital photography is a reliable, cost-effective measurement method of skin colour and should be further investigated for quantitative analysis of surgical outcomes.
Li, Hongkun; Guo, Jiajia; Ping, Hong; Liu, Lurui; Zhang, Minwei; Guan, Fengrui; Sun, Chunyan; Zhang, Qian
2011-12-15
With citrate-coated Au nanoparticles as colorimetric probe, a novel visual method for rapid assay of organophosphorus pesticides has been developed. The assay principle is based on catalytic hydrolysis of acetylthiocholine into thiocholine by acetylcholinesterase, which induces the aggregation of Au nanoparticles and the color change from claret-red to purple or even grey. The original plasmon absorption of Au nanoparticles at 522 nm decreases, and simultaneously, a new absorption band appears at 675 nm. The irreversible inhibition of organophosphorus pesticides on acetylcholinesterase prevents aggregation of Au nanoparticles. Under optimum conditions, the absorbance at 522 nm of Au nanoparticles is related linearly to the concentration of mathamidophos in the range of 0.02-1.42 μg/mL with a detection limit of 1.40 ng/mL. This colorimetric method has been successfully utilized to detect mathamidophos in vegetables with satisfactory results. The proposed colorimetric assay exhibits good reproducibility and accuracy, providing a simple and rapid method for the analysis of organophosphorus pesticides. Copyright © 2011 Elsevier B.V. All rights reserved.
Üzer, Ayşem; Can, Ziya; Akın, Ilknur; Erçağ, Erol; Apak, Reşat
2014-01-07
The heterocyclic nitramine compounds, hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX), are two most important military-purpose high explosives. Differentiation of RDX and HMX with colorimetric methods of determination has not yet been made because of their similar chemical structures. In this study, a sensitive colorimetric method for the determination of RDX and HMX was proposed on the basis of differential kinetics in the hydrolysis of the two compounds (yielding nitrite as a product) followed by their colorimetric determination using 4-aminothiophenol (4-ATP) modified gold nanoparticles (AuNPs) and naphthylethylene diamine (NED) as coupling agent for azo-dye formation, abbreviated as "4-ATP-AuNP+NED" colorimetric method. After alkaline hydrolysis in a 1 M Na2CO3 + 0.04 M NaOH mixture solution at room temperature, only RDX (but not HMX) was hydrolyzed to give a sufficient colorimetric response in neutralized solution, the molar absorptivity (ε) at 565 nm and the limit of detection (LOD) for RDX being (17.6 ± 1.3) × 10(3) L mol(-1) cm(-1) and 0.55 μg mL(-1), respectively. On the other hand, hot water bath (at 60 °C) hydrolysis enabled both nitramines, RDX and HMX, to give substantial colorimetric responses; i.e., ε and LOD for RDX were (32.8 ± 0.5) × 10(3) L mol(-1)cm(-1) and 0.20 μg mL(-1) and for HMX were (37.1 ± 2.8) × 10(3) L mol(-1)cm(-1) and 0.24 μg mL(-1), respectively. Unlike other AuNP-based nitrite sensors in the literature showing absorbance quenching within a relatively narrow concentration range, the developed sensor operated with an absorbance increase over a wide range of nitrite. Synthetic mixtures of (RDX + HMX) gave additive responses, and the proposed method was statistically validated against HPLC using nitramine mixtures.
Rajatileka, Shavanti; Steven, Andrew; Hemingway, Janet; Ranson, Hilary; Paine, Mark; Vontas, John
2010-01-01
Background Insecticide-based methods represent the most effective means of blocking the transmission of vector borne diseases. However, insecticide resistance poses a serious threat and there is a need for tools, such as diagnostic tests for resistance detection, that will improve the sustainability of control interventions. The development of such tools for metabolism-based resistance in mosquito vectors lags behind those for target site resistance mutations. Methodology/Principal Findings We have developed and validated a simple colorimetric assay for the detection of Epsilon class Glutathione transferases (GST)-based DDT resistance in mosquito species, such as Aedes aegypti, the major vector of dengue and yellow fever worldwide. The colorimetric assay is based on the specific alkyl transferase activity of Epsilon GSTs for the haloalkene substrate iodoethane, which produces a dark blue colour highly correlated with AaGSTE2-2-overexpression in individual mosquitoes. The colour can be measured visually and spectrophotometrically. Conclusions/Significance The novel assay is substantially more sensitive compared to the gold standard CDNB assay and allows the discrimination of moderate resistance phenotypes. We anticipate that it will have direct application in routine vector monitoring as a resistance indicator and possibly an important impact on disease vector control. PMID:20824165
Vitkova, O N; Kapustina, T P; Mikhailova, V V; Safonov, G A; Vlasova, N N; Belousova, R V
2015-01-01
The goal of this work was to demonstrate the results of the development of the enzyme-linked immunosorbent tests with chemiluminescence detection and colorimetric detection of specific viral antigens and antibodies for identifying the avian influenza and the Newcastle disease viruses: high sensitivity and specificity of the immuno- chemiluminescence assay, which are 10-50 times higher than those of the ELISA colorimetric method. The high effectiveness of the results and the automation of the process of laboratory testing (using a luminometer) allow these methods to be recommended for including in primary screening tests for these infectious diseases.
Alizadeh, Nastaran; Amiri, Mohammad Mehdi; Salek Moghadam, Alireza; Zarnani, Amir Hassan; Saadat, Farshid; Safavifar, Farnaz; Berahmeh, Azar; Khorramizadeh, Mohammad Reza
2013-05-15
There exists compelling evidence that Toll-like receptor 3 (TLR3) agonists can directly affect human cancer cells. The aim of this study was to investigate anti-cancer effects of TLR3 agonist in human breast cell line. We assessed potential effects of poly (A:U) on human breast cell line (MDA-MB-231) on a dose-response and time-course basis. Human breast cell line MDA-MB-231 was treated with different concentrations of poly (A:U) and lipopolysaccharide (LPS). Then, the following assays were performed on the treated cells: dose-response and time-course cytotoxicity using colorimetric method; matrix metalloproteinase-2 (MMP-2) activity using gelatin zymography method; apoptosis using annexin-v flowcytometry method; and relative expression of TLR3 and MMP-2 mRNA using reverse transcriptase polymerase chain reaction (RT-PCR) method. Following treatments, dose- response and time-course cytotoxicity using a colorimetric method, (MMP-2) activity (using gelatin zymography), apoptosis (using annexin-v flowcytometry method) assays and expression of TLR3 and MMP-2 genes (using PCR method) were performed. Cytotoxicity and flowcytometry analysis of poly (A:U) showed that poly (A:U) do not have any cytotoxic and apoptotic effects in different concentrations used. MMP-2 activity analysis showed significant decrease in higher concentrations (50 and 100 μg/ ml) between treated and untreated cells. Moreover, poly A:U treated cells demonstrated decreased expression of MMP-2 gene in higher concentrations. Collectively, our data indicated that human breast cancer cell line (MDA-MB-231) was highly responsive to poly (A:U). The antimetastatic effect of direct poly (A:U) and TLR3 interactions in MDA-MB-231 cells could provide new approaches in malignant tumor therapeutic strategy.
Wang, Xinhao; Chang, Te-Wei; Lin, Guohong; Gartia, Manas Ranjan; Liu, Gang Logan
2017-01-03
Colorimetric sensors usually suffer due to errors from variation in light source intensity, the type of light source, the Bayer filter algorithm, and the sensitivity of the camera to incoming light. Here, we demonstrate a self-referenced portable smartphone-based plasmonic sensing platform integrated with an internal reference sample along with an image processing method to perform colorimetric sensing. Two sensing principles based on unique nanoplasmonics enabled phenomena from a nanostructured plasmonic sensor, named as nanoLCA (nano Lycurgus cup array), were demonstrated here for colorimetric biochemical sensing: liquid refractive index sensing and optical absorbance enhancement sensing. Refractive indices of colorless liquids were measured by simple smartphone imaging and color analysis. Optical absorbance enhancement in the colorimetric biochemical assay was achieved by matching the plasmon resonance wavelength with the chromophore's absorbance peak wavelength. Such a sensing mechanism improved the limit of detection (LoD) by 100 times in a microplate reader format. Compared with a traditional colorimetric assay such as urine testing strips, a smartphone plasmon enhanced colorimetric sensing system provided 30 times improvement in the LoD. The platform was applied for simulated urine testing to precisely identify the samples with higher protein concentration, which showed potential point-of-care and early detection of kidney disease with the smartphone plasmonic resonance sensing system.
Xuan, Shi-Hai; Zhou, Yu-Gui; Shao, Bo; Cui, Ya-Lin; Li, Jian; Yin, Hong-Bo; Song, Xiao-Ping; Cong, Hui; Jing, Feng-Xiang; Jin, Qing-Hui; Wang, Hui-Min; Zhou, Jie
2009-11-01
Macrolide drugs, such as clarithromycin (CAM), are a key component of many combination therapies used to eradicate Helicobacter pylori. However, resistance to CAM is increasing in H. pylori and is becoming a serious problem in H. pylori eradication therapy. CAM resistance in H. pylori is mostly due to point mutations (A2142G/C, A2143G) in the peptidyltransferase-encoding region of the 23S rRNA gene. In this study an enzymic colorimetry-based DNA chip was developed to analyse single-nucleotide polymorphisms of the 23S rRNA gene to determine the prevalence of mutations in CAM-related resistance in H. pylori-positive patients. The results of the colorimetric DNA chip were confirmed by direct DNA sequencing. In 63 samples, the incidence of the A2143G mutation was 17.46 % (11/63). The results of the colorimetric DNA chip were concordant with DNA sequencing in 96.83 % of results (61/63). The colorimetric DNA chip could detect wild-type and mutant signals at every site, even at a DNA concentration of 1.53 x 10(2) copies microl(-1). Thus, the colorimetric DNA chip is a reliable assay for rapid and accurate detection of mutations in the 23S rRNA gene of H. pylori that lead to CAM-related resistance, directly from gastric tissues.
Method for hue plane preserving color correction.
Mackiewicz, Michal; Andersen, Casper F; Finlayson, Graham
2016-11-01
Hue plane preserving color correction (HPPCC), introduced by Andersen and Hardeberg [Proceedings of the 13th Color and Imaging Conference (CIC) (2005), pp. 141-146], maps device-dependent color values (RGB) to colorimetric color values (XYZ) using a set of linear transforms, realized by white point preserving 3×3 matrices, where each transform is learned and applied in a subregion of color space, defined by two adjacent hue planes. The hue plane delimited subregions of camera RGB values are mapped to corresponding hue plane delimited subregions of estimated colorimetric XYZ values. Hue planes are geometrical half-planes, where each is defined by the neutral axis and a chromatic color in a linear color space. The key advantage of the HPPCC method is that, while offering an estimation accuracy of higher order methods, it maintains the linear colorimetric relations of colors in hue planes. As a significant result, it therefore also renders the colorimetric estimates invariant to exposure and shading of object reflection. In this paper, we present a new flexible and robust version of HPPCC using constrained least squares in the optimization, where the subregions can be chosen freely in number and position in order to optimize the results while constraining transform continuity at the subregion boundaries. The method is compared to a selection of other state-of-the-art characterization methods, and the results show that it outperforms the original HPPCC method.
Wu, Luling; Li, Xiaolin; Huang, Chusen; Jia, Nengqin
2016-08-16
As traditional pH meters cannot work well for minute regions (such as subcellular organelles) and in harsh media, molecular pH-sensitive devices for monitoring pH changes in diverse local heterogeneous environments are urgently needed. Here, we report a new dual-modal colorimetric/fluorescence merocyanine-based molecular probe (CPH) for ratiometric sensing of pH. Compared with previously reported pH probes, CPH bearing the benzyl group at the nitrogen position of the indolium group and the phenol, which is used as the acceptor for proton, could respond to pH changes immediately through both the ratiometric fluorescence signal readout and naked-eye colorimetric observation. The sensing process was highly stable and reversible. Most importantly, the suitable pKa value (6.44) allows CPH to presumably accumulate in lysosomes and become a lysosome-target fluorescent probe. By using CPH, the intralysosomal pH fluctuation stimulated by antimalaria drug chloroquine was successfully tracked in live cells through the ratiometric fluorescence images. Additionally, CPH could be immobilized on test papers, which exhibited a rapid and reversible colorimetric response to acid/base vapor through the naked-eye colorimetric analysis. This proof-of-concept study presents the potential application of CPH as a molecular tool for monitoring intralysosomal pH fluctuation in live cells, as well as paves the way for developing the economic, reusable, and fast-response optical pH meters for colorimetric sensing acid/base vapor with direct naked-eye observation.
Field demonstration of on-site analytical methods for TNT and RDX in ground water
DOE Office of Scientific and Technical Information (OSTI.GOV)
Craig, H.; Ferguson, G.; Markos, A.
1996-12-31
A field demonstration was conducted to assess the performance of eight commercially-available and emerging colorimetric, immunoassay, and biosensor on-site analytical methods for explosives 2,4,6-trinitrotoluene (TNT) and hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) in ground water and leachate at the Umatilla Army Depot Activity, Hermiston, Oregon and US Naval Submarine Base, Bangor, Washington, Superfund sites. Ground water samples were analyzed by each of the on-site methods and results compared to laboratory analysis using high performance liquid chromatography (HPLC) with EPA SW-846 Method 8330. The commercial methods evaluated include the EnSys, Inc., TNT and RDX colorimetric test kits (EPA SW-846 Methods 8515 and 8510) with amore » solid phase extraction (SPE) step, the DTECH/EM Science TNT and RDX immunoassay test kits (EPA SW-846 Methods 4050 and 4051), and the Ohmicron TNT immunoassay test kit. The emerging methods tested include the antibody-based Naval Research Laboratory (NRL) Continuous Flow Immunosensor (CFI) for TNT and RDX, and the Fiber Optic Biosensor (FOB) for TNT. Accuracy of the on-site methods were evaluated using linear regression analysis and relative percent difference (RPD) comparison criteria. Over the range of conditions tested, the colorimetric methods for TNT and RDX showed the highest accuracy of the emerging methods for TNT and RDX. The colorimetric method was selected for routine ground water monitoring at the Umatilla site, and further field testing on the NRL CFI and FOB biosensors will continue at both Superfund sites.« less
Mount, D L; Nahlen, B L; Patchen, L C; Churchill, F C
1989-01-01
Two field-adapted colorimetric methods for measuring the antimalarial drug chloroquine in urine are described. Both are modifications of the method of Saker and Solomons for screening urine for phencyclidine and other drugs of abuse, using the colour reagent tetrabromophenolphthalein ethyl ester. One method is semiquantitative, detecting the presence of chloroquine (Cq) and its metabolites in urine with a 1 microgram/ml detection limit; it is more sensitive and reliable than the commonly used Dill-Glazko method and is as easy to apply in the field. The second method uses a hand-held, battery-operated filter photometer to quantify Cq and its metabolites with a 2 microgram/ml detection limit and a linear range up to 8 micrograms/ml. The first method was validated in the field using a published quantitative colorimetric method and samples from a malaria study in Nigeria. The second method was validated in the laboratory against high-performance liquid chromatographic results on paired samples from the Nigerian study. Both methods may be used in remote locations where malaria is endemic and no electricity is available.
NASA Astrophysics Data System (ADS)
Yu, Shanshan; Murakami, Yuri; Obi, Takashi; Yamaguchi, Masahiro; Ohyama, Nagaaki
2006-09-01
The article proposes a multispectral image compression scheme using nonlinear spectral transform for better colorimetric and spectral reproducibility. In the method, we show the reduction of colorimetric error under a defined viewing illuminant and also that spectral accuracy can be improved simultaneously using a nonlinear spectral transform called Labplus, which takes into account the nonlinearity of human color vision. Moreover, we show that the addition of diagonal matrices to Labplus can further preserve the spectral accuracy and has a generalized effect of improving the colorimetric accuracy under other viewing illuminants than the defined one. Finally, we discuss the usage of the first-order Markov model to form the analysis vectors for the higher order channels in Labplus to reduce the computational complexity. We implement a multispectral image compression system that integrates Labplus with JPEG2000 for high colorimetric and spectral reproducibility. Experimental results for a 16-band multispectral image show the effectiveness of the proposed scheme.
Visualizing Capsaicinoids: Colorimetric Analysis of Chili Peppers
ERIC Educational Resources Information Center
Thompson, Robert Q.; Chu, Christopher; Gent, Robin; Gould, Alexandra P.; Rios, Laura; Vertigan, Theresa M.
2012-01-01
A colorimetric method for total capsaicinoids in chili pepper ("Capsicum") fruit is described. The placental material of the pepper, containing 90% of the capsaicinoids, was physically separated from the colored materials in the pericarp and extracted twice with methanol, capturing 85% of the remaining capsaicinoids. The extract, evaporated and…
Fabricating a UV-Vis and Raman Spectroscopy Immunoassay Platform.
Hanson, Cynthia; Israelsen, Nathan D; Sieverts, Michael; Vargis, Elizabeth
2016-11-10
Immunoassays are used to detect proteins based on the presence of associated antibodies. Because of their extensive use in research and clinical settings, a large infrastructure of immunoassay instruments and materials can be found. For example, 96- and 384-well polystyrene plates are available commercially and have a standard design to accommodate ultraviolet-visible (UV-Vis) spectroscopy machines from various manufacturers. In addition, a wide variety of immunoglobulins, detection tags, and blocking agents for customized immunoassay designs such as enzyme-linked immunosorbent assays (ELISA) are available. Despite the existing infrastructure, standard ELISA kits do not meet all research needs, requiring individualized immunoassay development, which can be expensive and time-consuming. For example, ELISA kits have low multiplexing (detection of more than one analyte at a time) capabilities as they usually depend on fluorescence or colorimetric methods for detection. Colorimetric and fluorescent-based analyses have limited multiplexing capabilities due to broad spectral peaks. In contrast, Raman spectroscopy-based methods have a much greater capability for multiplexing due to narrow emission peaks. Another advantage of Raman spectroscopy is that Raman reporters experience significantly less photobleaching than fluorescent tags 1 . Despite the advantages that Raman reporters have over fluorescent and colorimetric tags, protocols to fabricate Raman-based immunoassays are limited. The purpose of this paper is to provide a protocol to prepare functionalized probes to use in conjunction with polystyrene plates for direct detection of analytes by UV-Vis analysis and Raman spectroscopy. This protocol will allow researchers to take a do-it-yourself approach for future multi-analyte detection while capitalizing on pre-established infrastructure.
Brotto, Laura; Battistutta, Franco; Tat, Lara; Comuzzo, Piergiorgio; Zironi, Roberto
2010-03-24
Some modifications to a previous nondestructive colorimetric method that permits evaluation of the oxygen diffusion rate through wine closures were proposed. The method is based on the reaction of indigo carmine solution with oxygen and the tristimulus measurement of the consequent color change. Simplified preparation and measurement procedures were set up, allowing the analysis of a large number of samples simultaneously. The method was applied to the evaluation of the variability within the lot of 20 different types of stoppers (synthetic, produced by molding, and natural cork). The closures were tested at a storage temperature of 26 degrees C. With regard to oxygen permeability, the natural cork stopper showed a low homogeneity within the lot, especially during the first month after bottling, whereas the synthetic closure showed a greater steadiness in the performance. The limits of the colorimetric method were also analyzed, and three possible causes of degradation of the indigo carmine solution were identified: oxygen, light, and heat.
Assessment of simple colorimetric procedures to determine smoking status of diabetic subjects.
Smith, R F; Mather, H M; Ellard, G A
1998-02-01
The performance of a simple colorimetric assay for urinary nicotine metabolites to assess smoking status in diabetic subjects (n = 251) was investigated. Several variations of the colorimetric assay and a qualitative extraction procedure were evaluated in comparison with a cotinine immunoassay as the "gold standard." Among these, the best overall performance was achieved with the qualitative test (sensitivity 95%; specificity 100%). The quantitative measurement of total nicotine metabolites performed less well (sensitivity 92%; specificity 97%) but could be improved by incorporating a blank extraction (sensitivity 98%; specificity 98%). Allowance for diuresis appeared to offer no advantage over the other methods. These results support previous findings regarding the use of these colorimetric procedures in nondiabetic subjects and, contrary to other recent observations, their performance was not impaired in diabetic patients.
Anthon, Gordon E; Barrett, Diane M
2008-09-01
A simple procedure for determining the galacturonic acid and methanol contents of soluble and insoluble pectins, relying on enzymatic pectin hydrolysis and colorimetric quantification, is described. Pectin samples are incubated with a commercial pectinase preparation, Viscozyme, then the galacturonic acid content of the hydrolyzed pectin is quantified colorimetrically using a modification of the Cu reduction procedure originally described by Avigad and Milner. This modification, substituting the commonly used Folin-Ciocalteau reagent for the arsenic containing Nelson reagent, gives a response that is linear, sensitive, and selective for uronic acids over neutral sugars. This method also avoids the use of concentrated acids needed for the commonly used m-phenylphenol method. Methanol, released by the action of the pectin methylesterase found in the Viscozyme, is quantified using alcohol oxidase and Purpald. This combined enzymatic and colorimetric procedure correctly determined the galacturonic acid and methanol content of purified, soluble citrus pectin. Application of the procedure to water insoluble pectins was evaluated with water insoluble material from apples and oranges. In both cases good agreement was obtained between this method and commonly used methods based on chemical pectin hydrolysis. Good agreement between these procedures was also found in the analysis of both soluble and insoluble pectins from several tomato products. Copyright © 2008 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Kopriva, Ivica; Popović Hadžija, Marijana; Hadžija, Mirko; Aralica, Gorana
2016-03-01
Recently, novel data-driven offset-sparsity decomposition (OSD) method was proposed by us to increase colorimetric difference between tissue-structures present in the color microscopic image of stained specimen in histopathology. The OSD method performs additive decomposition of vectorized spectral images into image-adapted offset term and sparse term. Thereby, the sparse term represents an enhanced image. The method was tested on images of the histological slides of human liver stained with hematoxylin and eosin, anti-CD34 monoclonal antibody and Sudan III. Herein, we present further results related to increase of colorimetric difference between tissue structures present in the images of human liver specimens with pancreatic carcinoma metastasis stained with Gomori, CK7, CDX2 and LCA, and with colon carcinoma metastasis stained with Gomori, CK20 and PAN CK. Obtained relative increase of colorimetric difference is in the range [19.36%, 103.94%].
Li, Bowei; Fu, Longwen; Zhang, Wei; Feng, Weiwei; Chen, Lingxin
2014-04-01
This paper presents a novel paper-based analytical device based on the colorimetric paper assays through its light reflectance. The device is portable, low cost (<20 dollars), and lightweight (only 176 g) that is available to assess the cost-effectiveness and appropriateness of the original health care or on-site detection information. Based on the light reflectance principle, the signal can be obtained directly, stably and user-friendly in our device. We demonstrated the utility and broad applicability of this technique with measurements of different biological and pollution target samples (BSA, glucose, Fe, and nitrite). Moreover, the real samples of Fe (II) and nitrite in the local tap water were successfully analyzed, and compared with the standard UV absorption method, the quantitative results showed good performance, reproducibility, and reliability. This device could provide quantitative information very conveniently and show great potential to broad fields of resource-limited analysis, medical diagnostics, and on-site environmental detection. © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Dixit, Chandra K; Bhakta, Snehasis; Macharia, John; Furtado, Jared; Suib, Steven L; Rusling, James F
2018-10-22
We have developed a novel method to develop epoxy silica nanoparticles (EfSiNP) in a single pot. High surface coverage of epoxy functional groups between 150 and 57000 molecules per particles (∼10 13 -10 16 molecules/mL of 200 nm EfSiNPs) was achieved for different preparation conditions. We then created a red colored probe by conjugating Fuchsin dye to the epoxy functionalities of EfSINPs. Anti-mouse IgG was co-immobilized with Fuchsin and their ratios were optimized for achieving optimum ratios by testing those in functional assays. Dye to antibody ratios were in good negative correlation with a coefficient of -1.00 measured at a confidence level of over 99%. We employed the developed non-enzymatic colorimetric immunonanoprobe for detecting mouse IgG in a direct immunoassay format. We achieved a sensitivity of 427 pg/mL with the assay. Copyright © 2018 Elsevier B.V. All rights reserved.
Laboratory Methods for the Measurement of Pollutants in Water and Waste Effluents
NASA Technical Reports Server (NTRS)
Ballinger, Dwight G.
1971-01-01
The requirement for accurate, precise, and rapid analytical procedures for the examination of water and waste samples requires the use of a variety of instruments. The instrumentation in water laboratories includes atomic absorption, UV-visible. and infrared spectrophotometers, automatic colorimetric analyzers, gas chromatographs and mass spectrometers. Because of the emphasis on regulatory action, attention is being directed toward quality control of analytical results. Among the challenging problems are the differentiation of metallic species in water at nanogram concentrations, rapid measurement of free cyanide and free ammonia, more sensitive methods for arsenic and selenium and improved characterization of organic contaminants.
A rapid colorimetric assay for mold spore germination using XTT tetrazolium salt
Carol A. Clausen; Vina W. Yang
2011-01-01
Current laboratory test methods to measure efficacy of new mold inhibitors are time consuming, some require specialized test equipment and ratings are subjective. Rapid, simple quantitative assays to measure the efficacy of mold inhibitors are needed. A quantitative, colorimetric microassay was developed using XTT tetrazolium salt to metabolically assess mold spore...
Azomethine H colorimetric method for determining dissolved boron in water
Spencer, R.R.; Erdmann, D.E.
1979-01-01
An automated colorimetric method for determining dissolved boron in water is described. The boron is complexed with azomethine H, which is readily available as the condensation product of H acid (8-amino-1-naphthol-3,6-disulfonic acid) and salicylaldehyde. The absorbance of the yellow complex formed is then measured colorimetrically at 410 nm. Interference effects from other dissolved species are minimized by the addition of diethylenetriaminepentaacetic acid (DTPA); however, iron, zinc, and bicarbonate interfere at concentrations above 400 ??g/L, 2000 ??g/L, and 200 mg/L, respectively. The bicarbonate interference can be eliminated by careful acidification of the sample with concentrated HCl to a pH between 5 and 6. Thirty samples per hour can be routinely analyzed over the range of from 10 to 400 ??g/L, boron.
Aptamer-mediated colorimetric method for rapid and sensitive detection of chloramphenicol in food.
Yan, Chao; Zhang, Jing; Yao, Li; Xue, Feng; Lu, Jianfeng; Li, Baoguang; Chen, Wei
2018-09-15
We report an aptamer-mediated colorimetric method for sensitive detection of chloramphenicol (CAP). The aptamer of CAP is immobilized by the hybridization with pre-immobilized capture probe in the microtiter plate. The horseradish peroxidase (HRP) is covalently attached to the aptamer by the biotin-streptavidin system for signal production. CAP will preferably bind with aptamer due to the high binding affinity, which attributes to the release of aptamer and HRP and thus, affects the optical signal intensity. Quantitative determination of CAP is successfully achieved in the wide range from 0.001 to 1000 ng/mL with detection limit of 0.0031 ng/mL, which is more sensitive than traditional immunoassays. This method is further validated by measuring the recovery of CAP spiked in two different food matrices (honey and fish). The aptamer-mediated colorimetric method can be a useful protocol for rapid and sensitive screening of CAP, and may be used as an alternative means for traditional immunoassays. Copyright © 2018 Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Cao, Bin; Liao, Ningfang; Li, Yasheng; Cheng, Haobo
2017-05-01
The use of spectral reflectance as fundamental color information finds application in diverse fields related to imaging. Many approaches use training sets to train the algorithm used for color classification. In this context, we note that the modification of training sets obviously impacts the accuracy of reflectance reconstruction based on classical reflectance reconstruction methods. Different modifying criteria are not always consistent with each other, since they have different emphases; spectral reflectance similarity focuses on the deviation of reconstructed reflectance, whereas colorimetric similarity emphasizes human perception. We present a method to improve the accuracy of the reconstructed spectral reflectance by adaptively combining colorimetric and spectral reflectance similarities. The different exponential factors of the weighting coefficients were investigated. The spectral reflectance reconstructed by the proposed method exhibits considerable improvements in terms of the root-mean-square error and goodness-of-fit coefficient of the spectral reflectance errors as well as color differences under different illuminants. Our method is applicable to diverse areas such as textiles, printing, art, and other industries.
False positive acetaminophen concentrations in patients with liver injury.
Polson, Julie; Wians, Frank H; Orsulak, Paul; Fuller, Dwain; Murray, Natalie G; Koff, Jonathan M; Khan, Adil I; Balko, Jody A; Hynan, Linda S; Lee, William M
2008-05-01
Acetaminophen toxicity is the most common form of acute liver failure in the U.S. After acetaminophen overdoses, quantitation of plasma acetaminophen can aid in predicting severity of injury. However, recent case reports have suggested that acetaminophen concentrations may be falsely increased in the presence of hyperbilirubinemia. We tested sera obtained from 43 patients with acute liver failure, mostly unrelated to acetaminophen, utilizing 6 different acetaminophen quantitation systems to determine the significance of this effect. In 36 of the 43 samples with bilirubin concentrations ranging from 1.0-61.5 mg/dl no acetaminophen was detectable by gas chromatography-mass spectroscopy. These 36 samples were then utilized to test the performance characteristics of 2 immunoassay and 4 enzymatic-colorimetric methods. Three of four colorimetric methods demonstrated 'detectable' values for acetaminophen in from 4 to 27 of the 36 negative samples, low concentration positive values being observed when serum bilirubin concentrations exceeded 10 mg/dl. By contrast, the 2 immunoassay methods (EMIT, FPIA) were virtually unaffected. The false positive values obtained were, in general, proportional to the quantity of bilirubin in the sample. However, prepared samples of normal human serum with added bilirubin showed a dose-response curve for only one of the 4 colorimetric assays. False positive acetaminophen tests may result when enzymatic-colorimetric assays are used, most commonly with bilirubin concentrations >10 mg/dl, leading to potential clinical errors in this setting. Bilirubin (or possibly other substances in acute liver failure sera) appears to affect the reliable measurement of acetaminophen, particularly with enzymatic-colorimetric assays.
Metastable α-AgVO3 microrods as peroxidase mimetics for colorimetric determination of H2O2.
Wang, Yi; Zhang, Dun; Wang, Jin
2017-12-01
Single phase metastable α-AgVO 3 microrods with high crystallinity, tetragonal rod-like microstructure, uniform particle size distribution, and good dispersion were synthesized by direct coprecipitation at room temperature. They are shown to be viable peroxidase mimics that catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine in the presence of H 2 O 2 . Kinetic analysis indicated typical Michaelis-Menten catalytic behavior. The findings were used to design a colorimetric assay for H 2 O 2 , best measured at 652 nm. The method has a linear response in the 60 to 200 μM H 2 O 2 concentration range, with a 2 μM detection limit. Benefitting from the chemical stability of the microrods, the method is well reproducible. It also is easily performed and highly specific. Graphic abstract Single phase metastable α-AgVO 3 microrods with high crystallinity, tetragonal rod-like microstructure, uniform particle size distribution, and good dispersion can efficiently catalyze the oxidation reaction of peroxidase substrate 3,3',5,5'-tetramethylbenzidine (TMB) in the presence of H 2 O 2 to produce a blue color change.
Lee, Mei-Feng; Chen, Yen-Hsu; Hsu, Hui-Jine; Peng, Chien-Fang
2010-10-01
In this study, we designed a simple and rapid colorimetric detection method, a one-tube loop-mediated isothermal amplification (LAMP)-PCR-hybridization-restriction endonuclease-ELISA [one-tube LAMP-PCR-HY-RE-ELISA] system, to detect resistance to isoniazid, ethambutol and streptomycin in strains of Mycobacterium tuberculosis isolated from clinical specimens. The clinical performance of this method for detecting isoniazid-resistant, ethambutol-resistant and streptomycin-resistant isolates of M. tuberculosis showed 98.9%, 94.3% and 93.8%, respectively. This assay is rapid and convenient that can be performed within one working day. One-tube LAMP-PCR-HY-RE-ELISA system was designed based on hot spot point mutations in target drug-resistant genes, using LAMP-PCR, hybridization, digestion with restriction endonuclease and colorimetric method of ELISA. In this study, LAMP assay was used to amplify DNA from drug-resistant M. tuberculosis, and ELISA was used for colorimetrical determination. This assay will be a useful tool for rapid diagnosis of mutant codons in strains of M. tuberculosis for isoniazid at katG 315 and katG 463, ethambutol at embB 306 and embB 497, and streptomycin at rpsL 43. Crown Copyright © 2010. Published by Elsevier B.V. All rights reserved.
Cheng, Ruojie; Liu, Siyao; Shi, Huijie; Zhao, Guohua
2018-01-05
A highly sensitive, specific and simple colorimetric sensor based on aptamer was established for the detection of polychlorinated biphenyls (PCB 77). The use of unmodified gold nanoparticles as a colorimetric probe for aptamer sensors enabled the highly sensitive and selective detection of polychlorinated biphenyls (PCB 77). A linear range of 0.5nM to 900nM was obtained for the colorimetric assay with a minimum detection limit of 0.05nM. In addition, by the methods of circular dichroism, UV and naked eyes, we found that the 35 base fragments retained after cutting 5 bases from the 5 'end of aptamer plays the most significant role in the PCB 77 specific recognition process. We found a novel way to truncated nucleotides to optimize the detection of PCB 77, and the selected nucleotides also could achieve high affinity with PCB 77. At the same time, the efficient detection of the PCB 77 by our colorimetric sensor in the complex environmental water samples was realized, which shows a good application prospect. Copyright © 2017 Elsevier B.V. All rights reserved.
Colorimetric detection of UV light-induced single-strand DNA breaks using gold nanoparticles.
Kim, Joong Hyun; Chung, Chan Ho; Chung, Bong Hyun
2013-02-21
We developed a colorimetric method to specifically detect single-strand DNA breaks using gold nanoparticles. In our assay, broken DNA cannot stabilize gold nanoparticles to prevent salt-induced aggregation as good as intact DNA can, and this effect can be easily observed with the naked eye as a red-to-purple color change.
NASA Astrophysics Data System (ADS)
Kärhä, Petri; Vaskuri, Anna; Mäntynen, Henrik; Mikkonen, Nikke; Ikonen, Erkki
2017-08-01
Spectral irradiance data are often used to calculate colorimetric properties, such as color coordinates and color temperatures of light sources by integration. The spectral data may contain unknown correlations that should be accounted for in the uncertainty estimation. We propose a new method for estimating uncertainties in such cases. The method goes through all possible scenarios of deviations using Monte Carlo analysis. Varying spectral error functions are produced by combining spectral base functions, and the distorted spectra are used to calculate the colorimetric quantities. Standard deviations of the colorimetric quantities at different scenarios give uncertainties assuming no correlations, uncertainties assuming full correlation, and uncertainties for an unfavorable case of unknown correlations, which turn out to be a significant source of uncertainty. With 1% standard uncertainty in spectral irradiance, the expanded uncertainty of the correlated color temperature of a source corresponding to the CIE Standard Illuminant A may reach as high as 37.2 K in unfavorable conditions, when calculations assuming full correlation give zero uncertainty, and calculations assuming no correlations yield the expanded uncertainties of 5.6 K and 12.1 K, with wavelength steps of 1 nm and 5 nm used in spectral integrations, respectively. We also show that there is an absolute limit of 60.2 K in the error of the correlated color temperature for Standard Illuminant A when assuming 1% standard uncertainty in the spectral irradiance. A comparison of our uncorrelated uncertainties with those obtained using analytical methods by other research groups shows good agreement. We re-estimated the uncertainties for the colorimetric properties of our 1 kW photometric standard lamps using the new method. The revised uncertainty of color temperature is a factor of 2.5 higher than the uncertainty assuming no correlations.
Highly selective colorimetric bacteria sensing based on protein-capped nanoparticles.
Qiu, Suyan; Lin, Zhenyu; Zhou, Yaomin; Wang, Donggen; Yuan, Lijuan; Wei, Yihua; Dai, Tingcan; Luo, Linguang; Chen, Guonan
2015-02-21
A rapid and cost-effective colorimetric sensor has been developed for the detection of bacteria (Bacillus subtilis was selected as an example). The sensor was designed to rely on lysozyme-capped AuNPs with the advantages of effective amplification and high specificity. In the sensing system, lysozyme was able to bind strongly to Bacillus subtilis, which effectively induced a color change of the solution from light purple to purplish red. The lowest concentration of Bacillus subtilis detectable by the naked eye was 4.5 × 10(3) colony-forming units (CFU) mL(-1). Similar results were discernable from UV-Vis absorption measurements. A good specificity was observed through a statistical analysis method using the SPSS software (version 17.0). This simple colorimetric sensor may therefore be a rapid and specific method for a bacterial detection assay in complex samples.
Novel assay procedures for the measurement of α-amylase in weather-damaged wheat.
Cornaggia, Claudio; Ivory, Ruth; Mangan, David; McCleary, Barry V
2016-01-30
The measurement of α-amylase (EC 3.2.1.1) in sprout-damaged grains is a crucial analysis yet a problematic one owing to the typically low α-amylase levels in ground wheat samples. A number of standardised methods such as the Falling Number method and the Ceralpha method exist which are routinely used for the assay of α-amylase. These methods, however, are either highly substrate-dependent or lack the required sensitivity to assess sprout damage. Novel colorimetric and fluorometric reagents have been prepared (Amylase HR, Amylase SD, BzCNPG7 reagent and BzMUG7 reagent) for the direct and specific assay of α-amylase activity in sprout-damaged wheat. Assays employing these reagents have been developed and optimised to include a decolourisation step using activated charcoal. When used in a convenient assay format, Amylase SD--containing EtNPG7 (II) as the colorimetric substrate and α-glucosidase as the ancillary enzyme--was found to be an excellent reagent for the assessment of sprout damage in wheat with incubation times as short as 5 min. The assay using Amylase SD is completely specific for α-amylase. The use of the Amylase SD assay represents a sensitive and valid alternative to the traditionally used Falling Number values for the assessment of sprout damage in wheat samples. © 2015 Society of Chemical Industry.
NASA Astrophysics Data System (ADS)
Vinod Kumar, V.; Anbarasan, S.; Christena, Lawrence Rene; SaiSubramanian, Nagarajan; Philip Anthony, Savarimuthu
2014-08-01
Hibiscus Sabdariffa (Gongura) plant extracts (leaves (HL) and stem (HS) were used for the first time in the green synthesis of bio-functionalized silver nanoparticles (AgNPs). The bio-functionality of AgNPs has been successfully utilized for selective colorimetric sensing of potentially health and environmentally hazardous Hg2+, Cd2+ and Pb2+ metal ions at ppm level in aqueous solution. Importantly, clearly distinguishable colour for all three metal ions was observed. The influence of extract preparation condition and pH were also explored on the formation of AgNPs. Both selectivity and sensitivity differed for AgNPs synthesized from different parts of the plant. Direct correlation between the stability of green synthesized AgNPs at different pH and its antibacterial effects has been established. The selective colorimetric sensing of toxic metal ions and antimicrobial effect of green synthesized AgNPs demonstrated the multifunctional applications of green nanotechnology.
ERIC Educational Resources Information Center
Fenk, Christopher J.; Kaufman, Nathan; Gerbig, Donald G., Jr.
2007-01-01
A new, fast and effective colorimetric analysis of the artificial sweetener aspartame is presented for application in undergraduate laboratory courses. This new method incorporates the use of a modified biuret reagent for selective detection and analysis of aspartame in aqueous solutions. The modified reagent is less caustic than the traditional…
NASA Technical Reports Server (NTRS)
Diaz, Neil C.; Gazda, Daniel B.; Fritz, James S.; Porter, Marc D.; Rutz, Jeff; Mudgett, Paul; Schultz, John
2004-01-01
Archived water samples collected on the International Space Station (ISS) and returned to Earth for analysis have, in a few instances, contained trace levels of heavy metals. Building on our previous advances using Colorimetric Solid Phase Extraction (C-SPE) as a biocide monitoring technique, we are devising methods for the low level monitoring of nickel(II), lead(II) and other heavy metals. C-SPE is a sorption-spectrophotometric platform based on the extraction of analytes onto a membrane impregnated with a colorimetric reagent that are then quantified on the surface of the membrane using a diffuse reflectance spectrophotometer. Along these lines, we have determined nickel(II) via complexation with dimethylglyoxime (DMG) and begun to examine the analysis of lead(II) by its reaction with 2,5- dimercapto-1,3,4-thiadiazole (DMTD) and 4-(2- pyridylazo)-resorcinol (PAR). These developments are also extending a new variant of C-SPE in which immobilized reagents are being incorporated into this methodology in order to optimize sample reaction conditions and to introduce the colorimetric reagent. This paper describes the status of our development of these two new methods.
NASA Astrophysics Data System (ADS)
Vallu, Rama Krishna; Velugula, Krishna; Doshi, Sejal; Chinta, Jugun Prakash
2018-01-01
Colorimetric and fluorimetric detection of toxic metal ions such as Hg2 + and Cr3 + has gained tremendous popularity over the conventional methods due to their operational simplicity, high selectivity, and speediness. Although numerous colorimetric and fluorescent receptors for Hg2 + or Cr3 + were reported in the literature, boronic acid-based receptors for these metal ions are rather scarce in the literature. Hence, in the present study dual function boronic acid conjugated rhodamine derivatives were developed, and their toxic metal ion detection abilities were studied by absorption, emission and visual detection methods. Absorption and emission spectral studies revealed that these derivatives displayed selectivity towards Hg2 +, Cr3 + and Fe3 + among the other metal ions studied by forming new absorption band. Both the derivatives exhibited colorimetric response towards Hg2 + and Cr3 + by the change in color of the solution to pink and reddish pink with Fe3 +. The detailed mechanism involved in the detection of Hg2 + was deduced by 1H NMR and ESI-MS studies. Further, these derivatives were used for fluorescence imaging of Hg2 + and Cr3 + in S. aureus bacterial cells. Thus the present manuscript demonstrated the use of boronic acid conjugated rhodamine derivatives as a dual function (colorimetric and fluorescent) probes and as imaging agents for Hg2 + and Cr3 +, which are known for their toxic influence on bacterial cells.
Meloni, Domenico; Spina, Antonio; Satta, Gianluca; Chessa, Vittorio
2016-06-25
In recent years, besides the consumption of fresh sea urchin specimens, the demand of minimally-processed roe has grown considerably. This product has made frequent consumption in restaurants possible and frauds are becoming widespread with the partial replacement of sea urchin roe with surrogates that are similar in colour. One of the main factors that determines the quality of the roe is its colour and small differences in colour scale cannot be easily discerned by the consumers. In this study we have applied a rapid colorimetric method for reveal the fraudulent partial substitution of semi-solid sea urchin roe with liquid egg yolk. Objective assessment of whiteness (L*), redness (a*), yellowness (b*), hue (h*), and chroma (C*) was carried out with a digital spectrophotometer using the CIE L*a*b* colour measurement system. The colorimetric method highlighted statistically significant differences among sea urchin roe and liquid egg yolk that could be easily discerned quantitatively.
Detection of proteins using a colorimetric bio-barcode assay.
Nam, Jwa-Min; Jang, Kyung-Jin; Groves, Jay T
2007-01-01
The colorimetric bio-barcode assay is a red-to-blue color change-based protein detection method with ultrahigh sensitivity. This assay is based on both the bio-barcode amplification method that allows for detecting miniscule amount of targets with attomolar sensitivity and gold nanoparticle-based colorimetric DNA detection method that allows for a simple and straightforward detection of biomolecules of interest (here we detect interleukin-2, an important biomarker (cytokine) for many immunodeficiency-related diseases and cancers). The protocol is composed of the following steps: (i) conjugation of target capture molecules and barcode DNA strands onto silica microparticles, (ii) target capture with probes, (iii) separation and release of barcode DNA strands from the separated probes, (iv) detection of released barcode DNA using DNA-modified gold nanoparticle probes and (v) red-to-blue color change analysis with a graphic software. Actual target detection and quantification steps with premade probes take approximately 3 h (whole protocol including probe preparations takes approximately 3 days).
Pundir, C S; Chauhan, Nidhi; Jyoti
2011-06-01
Ascorbate oxidase purified from Lagenaria siceraria fruit was immobilized onto epoxy resin "Araldite" membrane with 79.4% retention of initial activity of free enzyme. The biosensor showed optimum response within 15s at pH 5.8 and 35°C, which was directly proportional to ascorbate concentration ranging from 1-100μM. There was a good correlation (R(2) = 0.99) between serum ascorbic acid values by standard enzymic colorimetric method and the present method. The enzyme electrode was used for 200 times without considerable loss of activity during the span of 90 days when stored at 4°C.
Zhang, Xianxia; Xiao, Kunyi; Cheng, Liwei; Chen, Hui; Liu, Baohong; Zhang, Song; Kong, Jilie
2014-06-03
Rapid and efficient detection of cancer cells at their earliest stages is one of the central challenges in cancer diagnostics. We developed a simple, cost-effective, and highly sensitive colorimetric method for visually detecting rare cancer cells based on cell-triggered cyclic enzymatic signal amplification (CTCESA). In the absence of target cells, hairpin aptamer probes (HAPs) and linker DNAs stably coexist in solution, and the linker DNA assembles DNA-AuNPs, producing a purple solution. In the presence of target cells, the specific binding of HAPs to the target cells triggers a conformational switch that results in linker DNA hybridization and cleavage by nicking endonuclease-strand scission cycles. Consequently, the cleaved fragments of linker DNA can no longer assemble into DNA-AuNPs, resulting in a red color. UV-vis spectrometry and photograph analyses demonstrated that this CTCESA-based method exhibited selective and sensitive colorimetric responses to the presence of target CCRF-CEM cells, which could be detected by the naked eye. The linear response for CCRF-CEM cells in a concentration range from 10(2) to 10(4) cells was obtained with a detection limit of 40 cells, which is approximately 20 times lower than the detection limit of normal AuNP-based methods without amplification. Given the high specificity and sensitivity of CTCESA, this colorimetric method provides a sensitive, label-free, and cost-effective approach for early cancer diagnosis and point-to-care applications.
Tsukatani, Tadayuki; Suenaga, Hikaru; Higuchi, Tomoko; Shiga, Masanobu; Noguchi, Katsuya; Matsumoto, Kiyoshi
2011-01-01
Bacteria are fundamentally divided into two groups: Gram-positive and Gram-negative. Although the Gram stain and other techniques can be used to differentiate these groups, some issues exist with traditional approaches. In this study, we developed a method for differentiating Gram-positive and -negative bacteria using a colorimetric microbial viability assay based on the reduction of the tetrazolium salt {2-(2-methoxy-4-nitrophenyl)-3-(4-nitrophenyl)-5-(2,4-disulfophenyl)-2H-tetrazolium, monosodium salt} (WST-8) via 2-methyl-1,4-napthoquinone with a selection medium. We optimized the composition of the selection medium to allow the growth of Gram-negative bacteria while inhibiting the growth of Gram-positive bacteria. When the colorimetric viability assay was carried out in a selection medium containing 0.5µg/ml crystal violet, 5.0 µg/ml daptomycin, and 5.0µg/ml vancomycin, the reduction in WST-8 by Gram-positive bacteria was inhibited. On the other hand, Gram-negative bacteria produced WST-8-formazan in the selection medium. The proposed method was also applied to determine the Gram staining characteristics of bacteria isolated from various foodstuffs. There was good agreement between the results obtained using the present method and those obtained using a conventional staining method. These results suggest that the WST-8 colorimetric assay with selection medium is a useful technique for accurately differentiating Gram-positive and -negative bacteria.
Direct Estimate of Cocoa Powder Content in Cakes by Colorimetry and Photoacoustic Spectroscopy
NASA Astrophysics Data System (ADS)
Dóka, O.; Bicanic, D.; Kulcsár, R.
2014-12-01
Cocoa is a very important ingredient in the food industry and largely consumed worldwide. In this investigation, colorimetry and photoacoustic spectroscopy were used to directly assess the content of cocoa powder in cakes; both methods provided satisfactory results. The calibration curve was constructed using a series of home-made cakes containing varying amount of cocoa powder. Then, at a later stage, the same calibration curve was used to quantify the cocoa content of several commercially available cakes. For self-made cakes, the relationship between the PAS signal and the content of cocoa powder was linear while a quadratic dependence was obtained for the colorimetric index (brightness) and total color difference ().
Optimum color filters for CCD digital cameras
NASA Astrophysics Data System (ADS)
Engelhardt, Kai; Kunz, Rino E.; Seitz, Peter; Brunner, Harald; Knop, Karl
1993-12-01
As part of the ESPRIT II project No. 2103 (MASCOT) a high performance prototype color CCD still video camera was developed. Intended for professional usage such as in the graphic arts, the camera provides a maximum resolution of 3k X 3k full color pixels. A high colorimetric performance was achieved through specially designed dielectric filters and optimized matrixing. The color transformation was obtained by computer simulation of the camera system and non-linear optimization which minimized the perceivable color errors as measured in the 1976 CIELUV uniform color space for a set of about 200 carefully selected test colors. The color filters were designed to allow perfect colorimetric reproduction in principle and at the same time with imperceptible color noise and with special attention to fabrication tolerances. The camera system includes a special real-time digital color processor which carries out the color transformation. The transformation can be selected from a set of sixteen matrices optimized for different illuminants and output devices. Because the actual filter design was based on slightly incorrect data the prototype camera showed a mean colorimetric error of 2.7 j.n.d. (CIELUV) in experiments. Using correct input data in the redesign of the filters, a mean colorimetric error of only 1 j.n.d. (CIELUV) seems to be feasible, implying that it is possible with such an optimized color camera to achieve such a high colorimetric performance that the reproduced colors in an image cannot be distinguished from the original colors in a scene, even in direct comparison.
NASA Astrophysics Data System (ADS)
Chavada, Vijay D.; Bhatt, Nejal M.; Sanyal, Mallika; Shrivastav, Pranav S.
2017-01-01
In this article we report a novel method for colorimetric sensing and selective determination of a non-chromophoric drug-azithromycin, which lacks native absorbance in the UV-Visible region using unmodified silver nanoparticles (AgNPs). The citrate-capped AgNps dispersed in water afforded a bright yellow colour owing to the electrostatic repulsion between the particles due to the presence of negatively charged surface and showed surface plasmon resonance (SPR) band at 394 nm. Addition of positively charged azithromycin at a concentration as low as 0.2 μM induced rapid aggregation of AgNPs by neutralizing the negative charge on the particle surface. This phenomenon resulted in the colour change from bright yellow to purple which could be easily observed by the naked eye. This provided a simple platform for rapid determination of azithromycin based on colorimetric measurements. The factors affecting the colorimetric response like pH, volume of AgNPs suspension and incubation time were suitably optimized. The validated method was found to work efficiently in the established concentration range of 0.2-100.0 μM using two different calibration models. The selectivity of the method was also evaluated by analysis of nanoparticles-aggregation response upon addition of several anions, cations and some commonly prescribed antibiotics. The method was successfully applied for the analysis of azithromycin in pharmaceuticals and spiked human plasma samples with good accuracy and precision. The simplicity, efficiency and cost-effectiveness of the method hold tremendous potential for the analysis of such non-chromophoric pharmaceuticals.
NASA Astrophysics Data System (ADS)
Xiong, Yanmei; Zhang, Yuyan; Rong, Pengfei; Yang, Jie; Wang, Wei; Liu, Dingbin
2015-09-01
We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose.We developed a simple high-throughput colorimetric assay to detect glucose based on the glucose oxidase (GOx)-catalysed enlargement of gold nanoparticles (AuNPs). Compared with the currently available glucose kit method, the AuNP-based assay provides higher clinical sensitivity at lower cost, indicating its great potential to be a powerful tool for clinical screening of glucose. Electronic supplementary information (ESI) available: Experimental section and additional figures. See DOI: 10.1039/c5nr03758a
Simple colorimetric detection of doxycycline and oxytetracycline using unmodified gold nanoparticles
NASA Astrophysics Data System (ADS)
Li, Jie; Fan, Shumin; Li, Zhigang; Xie, Yuanzhe; Wang, Rui; Ge, Baoyu; Wu, Jing; Wang, Ruiyong
2014-08-01
The interaction between tetracycline antibiotics and gold nanoparticles was studied. With citrate-coated gold nanoparticles as colorimetric probe, a simple and rapid detection method for doxycycline and oxytetracycline has been developed. This method relies on the distance-dependent optical properties of gold nanoparticles. In weakly acidic buffer medium, doxycycline and oxytetracycline could rapidly induce the aggregation of gold nanoparticles, resulting in red-to-blue (or purple) colour change. The experimental parameters were optimized with regard to pH, the concentration of the gold nanoparticles and the reaction time. Under optimal experimental conditions, the linear range of the colorimetric sensor for doxycycline/oxytetracycline was 0.06-0.66 and 0.59-8.85 μg mL-1, respectively. The corresponding limit of detection for doxycycline and oxytetracycline was 0.0086 and 0.0838 μg mL-1, respectively. This assay was sensitive, selective, simple and readily used to detect tetracycline antibiotics in food products.
NASA Astrophysics Data System (ADS)
Zhu, Yiting; Narendran, Nadarajah; Tan, Jianchuan; Mou, Xi
2014-09-01
The organic light-emitting diode (OLED) has demonstrated its novelty in displays and certain lighting applications. Similar to white light-emitting diode (LED) technology, it also holds the promise of saving energy. Even though the luminous efficacy values of OLED products have been steadily growing, their longevity is still not well understood. Furthermore, currently there is no industry standard for photometric and colorimetric testing, short and long term, of OLEDs. Each OLED manufacturer tests its OLED panels under different electrical and thermal conditions using different measurement methods. In this study, an imaging-based photometric and colorimetric measurement method for OLED panels was investigated. Unlike an LED that can be considered as a point source, the OLED is a large form area source. Therefore, for an area source to satisfy lighting application needs, it is important that it maintains uniform light level and color properties across the emitting surface of the panel over a long period. This study intended to develop a measurement procedure that can be used to test long-term photometric and colorimetric properties of OLED panels. The objective was to better understand how test parameters such as drive current or luminance and temperature affect the degradation rate. In addition, this study investigated whether data interpolation could allow for determination of degradation and lifetime, L70, at application conditions based on the degradation rates measured at different operating conditions.
Li, Daxiu; Xie, Jiaqing; Zhou, Wenjiao; Jiang, Bingying; Yuan, Ruo; Xiang, Yun
2017-11-01
The determination of the level of Cu 2+ plays important roles in disease diagnosis and environmental monitoring. By coupling Cu + -catalyzed click chemistry and metal ion-dependent DNAzyme cyclic amplification, we have developed a convenient and sensitive colorimetric sensing method for the detection of Cu 2+ in human serums. The target Cu 2+ can be reduced by ascorbate to form Cu + , which catalyzes the azide-alkyne cycloaddition between the azide- and alkyne-modified DNAs to form Mg 2+ -dependent DNAzymes. Subsequently, the Mg 2+ ions catalyze the cleavage of the hairpin DNA substrate sequences of the DNAzymes and trigger cyclic generation of a large number of free G-quadruplex sequences, which bind hemin to form the G-quadruplex/hemin artificial peroxidase to cause significant color transition of the sensing solution for sensitive colorimetric detection of Cu 2+ . This method shows a dynamic range of 5 to 500 nM and a detection limit of 2 nM for Cu 2+ detection. Besides, the level of Cu 2+ in human serums can also be determined by using this sensing approach. With the advantages of simplicity and high sensitivity, such sensing method thus holds great potential for on-site determination of Cu 2+ in different samples. Graphical abstract Sensitive colorimetric detection of copper (II) by coupling click chemistry with metal ion-dependentDNAzymes.
Convert a low-cost sensor to a colorimeter using an improved regression method
NASA Astrophysics Data System (ADS)
Wu, Yifeng
2008-01-01
Closed loop color calibration is a process to maintain consistent color reproduction for color printers. To perform closed loop color calibration, a pre-designed color target should be printed, and automatically measured by a color measuring instrument. A low cost sensor has been embedded to the printer to perform the color measurement. A series of sensor calibration and color conversion methods have been developed. The purpose is to get accurate colorimetric measurement from the data measured by the low cost sensor. In order to get high accuracy colorimetric measurement, we need carefully calibrate the sensor, and minimize all possible errors during the color conversion. After comparing several classical color conversion methods, a regression based color conversion method has been selected. The regression is a powerful method to estimate the color conversion functions. But the main difficulty to use this method is to find an appropriate function to describe the relationship between the input and the output data. In this paper, we propose to use 1D pre-linearization tables to improve the linearity between the input sensor measuring data and the output colorimetric data. Using this method, we can increase the accuracy of the regression method, so as to improve the accuracy of the color conversion.
A MODIFIED LOW COST COLOURIMETRIC METHOD FOR PARACETAMOL (ACETAMINOPHEN) MEASUREMENT IN PLASMA
Shihana, Fathima; Dissanayake, Dhammika Menike; Dargan, Paul Ivor; Dawson, Andrew Hamilton
2011-01-01
Background Despite a significant increase in the number of patients with paracetamol poisoning in the developing world, plasma paracetamol assays are not widely available. The purpose of this study was to assess a low cost modified colorimetric paracetamol assay that has the potential to be performed in small laboratories with restricted resources. Methods The paracetamol assay used in this study was based on the Glynn and Kendal colorimetric method with a few modifications in order to decrease the production of nitrous gas and thereby reduce infrastructure costs. Preliminary validation studies were performed using spiked aqueous samples with known concentrations of paracetamol. Subsequently, the results from the colorimetric method for 114 stored clinical samples from patients with paracetamol poisoning were compared with those from the current gold-standard high-performance liquid chromatography (HPLC) method. A prospective survey, assessing the clinical use of the paracetamol assay, was performed on all patients with paracetamol poisoning attending the Peradeniya General Hospital, Sri Lanka over a ten-month period. Results The recovery study showed an excellent correlation (r2 >0.998) for paracetamol concentrations from 25- 400 mg/l. The final yellow colour was stable for at least 10 minutes at room temperature. There was also excellent correlation with the HPLC method (r2=0.9758). In the clinical cohort study, use of the antidote N-acetylcysteine was avoided in over a third of patients who had a plasma paracetamol concentration measured. The cost of consumables used per assay was $0.50 (US). Conclusions This colorimetric paracetamol assay is reliable and accurate and can be performed rapidly, easily and economically. Use of this assay in resource poor clinical settings has the potential to have a significant clinical and economic impact on the management of paracetamol poisoning. PMID:20095813
Achromatic-chromatic colorimetric sensors for on-off type detection of analytes.
Heo, Jun Hyuk; Cho, Hui Hun; Lee, Jin Woong; Lee, Jung Heon
2014-12-21
We report the development of achromatic colorimetric sensors; sensors changing their colors from achromatic black to other chromatic colors. An achromatic colorimetric sensor was prepared by mixing a general colorimetric indicator, whose color changes between chromatic colors, and a complementary colored dye with no reaction to the targeted analyte. As the color of an achromatic colorimetric sensor changes from black to a chromatic color, the color change could be much easily recognized than general colorimetric sensors with naked eyes. More importantly, the achromatic colorimetric sensors enable on-off type recognition of the presence of analytes, which have not been achieved from most colorimetric sensors. In addition, the color changes from some achromatic colorimetric sensors (achromatic Eriochrome Black T and achromatic Benedict's solution) could be recognized with naked eyes at much lower concentration ranges than normal chromatic colorimetric sensors. These results provide new opportunities in the use of colorimetric sensors for diverse applications, such as harsh industrial, environmental, and biological detection.
Lee, HyungJae; Choi, Mihye; Hwang, Sang-Hyun; Cho, Youngnam
2018-01-01
Purpose: As human papillomavirus (HPV) is primarily responsible for the development of cervical cancer, significant efforts have been devoted to develop novel strategies for detecting and identifying HPV DNA in urine. The analysis of target DNA sequences in urine offers a potential alternative to conventional methods as a non-invasive clinical screening and diagnostic assessment tool for the detection of HPV. However, the lack of efficient approaches to isolate and directly detect HPV DNA in urine has restricted its potential clinical use. In this study, we demonstrated a novel approach of using polyethylenimine-conjugated magnetic polypyrrole nanowires (PEI-mPpy NWs) for the extraction, identification, and PCR-free colorimetric detection of high-risk strains of HPV DNA sequences, particularly HPV-16 and HPV-18, in urine specimens of cervical cancer patients. Materials and Methods: We fabricated and characterized polyethylenimine-conjugated magnetic nanowires (PEI/mPpy NWs). PEI/mPpy NWs-based HPV DNA isolation and detection strategy appears to be a cost-effective and practical technology with greater sensitivity and accuracy than other urine-based methods. Results: The analytical and clinical performance of PEI-mPpy NWs was evaluated and compared with those of cervical swabs, demonstrating a superior type-specific concordance rate of 100% between urine and cervical swabs, even when using a small volume of urine (300 µL). Conclusion: We envision that PEI-mPpy NWs provide substantive evidence for clinical diagnosis and management of HPV-associated disease with their excellent performance in the recovery and detection of HPV DNA from minimal amounts of urine samples. PMID:29290816
Mandal, Shreya; Patra, Arpita; Samanta, Animesh; Roy, Suchismita; Mandal, Arpita; Mahapatra, Tapasi Das; Pradhan, Shrabani; Das, Koushik; Nandi, Dilip Kumar
2013-01-01
Objective To investigate phytochemical screening, antimicrobial activity and qualitative thin layer chromatographic separation of flavonoid components, antioxidant activity and total flavonoid compound of Terminalia arjuna. Methods For phytochemical screening, some common and available standard tests were done. Antimicrobial bioassay was done through agar well diffusion method. Detection of antioxidant activity and flavonoid compounds were done through thin layer chromatography. Total antioxidant activity was measured by 2, 2-diphenyl-1-picrylhydrazyl (DPPH) in colorimetric method. Aluminum chloride colorimetric method was used for total flavonoid determination. Results Phytochemical screening showed the active compounds presence in high concentration, such as phytosterol, lactones, flavonoids, phenolic compounds and tannins and glycosides. The antimicrobial activity of extract showed that greater inhibition zone against Gram negative bacteria than Gram positive bacteria. This methanolic extract showed a promising antioxidant activity, as absorption of DPPH redicles decreased in DPPH free radical scavenging assay. Flavonoids components having antioxidant property present in the methanol extract at a level of 199.00 mg quercetin equivalent/g of dried methanol extract in colorimetric method. Conclusions The Terminalia arjuna bark extract revealed the presence of bio-active constituents which are known to exhibit medicinal as well as physiological activities. PMID:24093787
Color digital halftoning taking colorimetric color reproduction into account
NASA Astrophysics Data System (ADS)
Haneishi, Hideaki; Suzuki, Toshiaki; Shimoyama, Nobukatsu; Miyake, Yoichi
1996-01-01
Taking colorimetric color reproduction into account, the conventional error diffusion method is modified for color digital half-toning. Assuming that the input to a bilevel color printer is given in CIE-XYZ tristimulus values or CIE-LAB values instead of the more conventional RGB or YMC values, two modified versions based on vector operation in (1) the XYZ color space and (2) the LAB color space were tested. Experimental results show that the modified methods, especially the method using the LAB color space, resulted in better color reproduction performance than the conventional methods. Spatial artifacts that appear in the modified methods are presented and analyzed. It is also shown that the modified method (2) with a thresholding technique achieves a good spatial image quality.
Methods for the Measurement of a Bacterial Enzyme Activity in Cell Lysates and Extracts
Mendz, George; Hazell, Stuart
1998-01-01
The kinetic characteristics and regulation of aspartate carbamoyltransferase activity were studied in lysates and cell extracts of Helicobacter pylori by three diffirent methods. Nuclear magnetic resonance spectroscopy, radioactive tracer analysis, and spectrophotometry were employed in conjunction to identify the properties of the enzyme activity and to validate the results obtained with each assay. NMR spectroscopy was the most direct method to provide proof of ACTase activity; radioactive tracer analysis was the most sensitive technique and a microtitre-based colorimetric assay was the most cost-and time-efficient for large scale analyses. Freeze-thawing was adopted as the preferred method for cell lysis in studying enzyme activity in situ. This study showed the benefits of employing several different complementary methods to investigate bacterial enzyme activity. PMID:12734591
NASA Astrophysics Data System (ADS)
Wachiralurpan, Sirirat; Sriyapai, Thayat; Areekit, Supatra; Sriyapai, Pichapak; Augkarawaritsawong, Suphitcha; Santiwatanakul, Somchai; Chansiri, Kosum
2018-04-01
ABSTRACT Listeria monocytogenes is a major foodborne pathogen of global health concern. Herein, the rapid diagnosis of L. monocytogenes has been achieved using loop-mediated isothermal amplification (LAMP) based on the phosphatidylcholine-phospholipase C gene (plcB). Colorimetric detection was then performed through the formation of DNA concatemers and a gold nanoparticle/DNA probe complex (GNP/DNA probe). The overall detection process was accomplished within approximately 1 h with no need for complicated equipment. The limits of detection for L. monocytogenes in the forms of purified genomic DNA and pure culture were 800 fg and 2.82 CFU mL-1, respectively. No cross reactions were observed from closely related bacteria species. The LAMP-GNP/DNA probe assay was applied to the detection of 200 raw chicken meat samples and compared to routine standard methods. The data revealed that the specificity, sensitivity and accuracy were 100%, 90.20% and 97.50%, respectively. The present assay was 100% in conformity with LAMP-agarose gel electrophoresis assay. Five samples that were negative by both assays appeared to have the pathogen at below the level of detection. The assay can be applied as a rapid direct screening method for L. monocytogenes.
NASA Astrophysics Data System (ADS)
Cao, Qian; Wan, Xiaoxia; Li, Junfeng; Liu, Qiang; Liang, Jingxing; Li, Chan
2016-10-01
This paper proposed two weight functions based on principal component analysis (PCA) to reserve more colorimetric information in spectral data compression process. One weight function consisted of the CIE XYZ color-matching functions representing the characteristic of the human visual system, while another was made up of the CIE XYZ color-matching functions of human visual system and relative spectral power distribution of the CIE standard illuminant D65. The improvement obtained from the proposed two methods were tested to compress and reconstruct the reflectance spectra of 1600 glossy Munsell color chips and 1950 Natural Color System color chips as well as six multispectral images. The performance was evaluated by the mean values of color difference under the CIE 1931 standard colorimetric observer and the CIE standard illuminant D65 and A. The mean values of root mean square errors between the original and reconstructed spectra were also calculated. The experimental results show that the proposed two methods significantly outperform the standard PCA and another two weighted PCA in the aspects of colorimetric reconstruction accuracy with very slight degradation in spectral reconstruction accuracy. In addition, weight functions with the CIE standard illuminant D65 can improve the colorimetric reconstruction accuracy compared to weight functions without the CIE standard illuminant D65.
NASA Astrophysics Data System (ADS)
Chen, Huan; Li, Zhihong; Liu, Xueting; Zhong, Jianhai; Lin, Tianran; Guo, Liangqia; Fu, Fengfu
2017-10-01
The peroxidase-like catalytic activity of MoS2 nanomaterials has been utilized for colorimetric bioassays and medical diagnostics. However, the application of peroxidase-like catalytic activity of MoS2 nanomaterials in environmental analysis was seldom explored. Herein, copper ions were found to inhibit the peroxidase-like catalytic activity of MoS2 nanosheets, which can catalyze the oxidation of 3, 3‧, 5, 5‧-tetramethylbenzidine by H2O2 to produce a colorimetric product. Based on this finding, a simple sensitive colorimetric method for the detection of copper ions was developed. In the presence of copper ions, the absorbance and color of the solution decreased with the increasing concentration of copper ions. The color of the solution can be used to semi-quantitative on-site assay of copper ions by naked eyes. A linear relationship between the absorbance and the concentration of copper ions was observed in the range of 0.4-4.0 μmol L- 1 with a detection limit of 92 nmol L- 1, which was much lower than the maximum contaminant level of copper in drinking water legislated by the Environmental Protection Agency of USA and the World Health Organization. The method was applied to detect copper ions in environmental water samples with satisfactory results.
Mondal, Bhairab; N, Bhavanashri; Ramlal, Shylaja; Kingston, Joseph
2018-02-14
In the present study, a colorimetric DNAzymes biosensor strategy was devised in combination with immunomagnetic separation for rapid and easy detection of enterotoxin B harboring Staphylococcus aureus from food and clinical samples. The method employs immunocapture of S. aureus and amplification of seb gene by DNAzyme complementary sequence integrated forward primer and with specific reverse primer. The DNAzyme sequence integrated dsDNA PCR products when treated with hemin and TMB (3,3',5,5'-tetramethylbenzidine) in the presence of H 2 O 2 produce colorimetric signal. A linear relationship of optical signal with the initial template of seb was obtained which could be monitored by visually or spectrophotrometrically for qualitative and quantitative detection. The limit of detection for the assay was approximately 10 2 CFU/mL of seb gene harboring target. This method is convenient compared to gel based and ELISA systems. Further, spiking studies and analysis on natural samples emphasized the robustness and applicability of developed method. Altogether, the established assay could be a reliable alternative, low-cost, viable detection tool for the routine investigation of seb from food and clinical sources.
NASA Astrophysics Data System (ADS)
Tavallali, Hossein; Deilamy-Rad, Gohar; Moaddeli, Ali; Asghari, Khadijeh
2017-08-01
A new selective probe based on copper complex of Indigo Carmine (IC-Cu2) for colorimetric, naked-eye, and fluorimetric recognition of mono hydrogen phosphate (MHP) ion in H2O/DMSO (4:1 v/v, 1.0 mmol L- 1 HEPES buffer solution pH 7.5) was developed. Detection limit of HPO42 - determination, achieved by fluorimetric and 3lorimetric method, are 0.071 and 1.46 μmol L- 1, respectively. Potential, therefore is clearly available in IC-Cu2 complex to detect HPO42 - in micromolar range via dual visible color change and fluorescence response. Present method shows high selectivity toward HPO42 - over other phosphate species and other anions and was successfully utilized for analysis of P2O5 content of a fertilizer sample. The results obtained by proposed chemosensor presented good agreement with those obtained the colorimetric reference method. INHIBIT and IMPLICATION logic gates operating at molecular level have been achieved using Cu2 + and HPO42 - as chemical inputs and UV-Vis absorbance signal as output.
NASA Astrophysics Data System (ADS)
Amirjani, Amirmostafa; Bagheri, Mozhgan; Heydari, Mojgan; Hesaraki, Saeed
2016-09-01
In this work, a rapid and simple colorimetric method based on the surface plasmon resonance of silver nanoparticles (AgNPs) was developed for the detection of the drug Timolol. The method used is based on the interaction of Timolol with the surface of the as-synthesized AgNPs, which promotes aggregation of the nanoparticles. This aggregation exploits the surface plasmon resonance through the electric dipole-dipole interaction and coupling among the agglomerated particles, hence bringing forth distinctive changes in the spectra as well as the color of colloidal silver. UV-vis spectrophotometery was used to monitor the changes of the localized surface plasmon resonance of AgNPs at wavelengths of 400 and 550 nm. The developed colorimetric sensor has a wide dynamic range of 1.0 × 10-7 M-1.0 × 10-3 M for detection of Timolol with a low detection limit of 1.2 × 10-6 M. The proposed method was successfully applied for the determination of Timolol concentration in ophthalmic eye-drop solution with a response time lower than 40 s.
Martín-Alonso, Manuel; Pena-Pereira, Francisco; Lavilla, Isela; Bendicho, Carlos
2018-03-13
This work reports on the implementation of gold nanorods (AuNRs) in headspace solvent microextraction for colorimetric determination of volatile analyte derivatives in a single drop. The exposure of AuNRs to both H 2 Se and elemental mercury (Hg 0 ) results in a shift of the longitudinal plasmonic band, unlike a number of volatiles. Accordingly, a method is reported for the determination of Hg 0 with potential applicability to the determination of thiomersal (sodium ethylmercurithiosalicylate). It is based on the photochemical decomposition of thiomersal into Hg(II) and subsequent exposure of AuNRs-containing microdrop to in situ generated Hg 0 . Colorimetric analysis of the enriched drop was carried out without dilution by means of a cuvetteless microvolume UV-vis spectrometer. Under optimal conditions, the limit of detection was 0.5 ng mL -1 (as Hg). The repeatability, expressed as relative standard deviation, was 8.4% (for n = 10). AuNRs exposed to increasing concentrations of the analyte were characterized by means of transmission electron microscopy and UV-vis spectrophotometry to ascertain the mechanism of detection. The method was finally applied to the determination of thiomersal in various pharmaceutical samples and showed quantitative recoveries. Graphical abstract Schematic illustration of a miniaturized colorimetric method based on the use of a microdrop of gold nanorods (AuNRs) for thiomersal determination in pharmaceuticals. It is based on the photochemical decomposition of thiomersal and subsequent Hg 0 generation with in-drop amalgamation.
Vinod Kumar, V; Anbarasan, S; Christena, Lawrence Rene; SaiSubramanian, Nagarajan; Philip Anthony, Savarimuthu
2014-08-14
Hibiscus Sabdariffa (Gongura) plant extracts (leaves (HL) and stem (HS)) were used for the first time in the green synthesis of bio-functionalized silver nanoparticles (AgNPs). The bio-functionality of AgNPs has been successfully utilized for selective colorimetric sensing of potentially health and environmentally hazardous Hg(2+), Cd(2+) and Pb(2+) metal ions at ppm level in aqueous solution. Importantly, clearly distinguishable colour for all three metal ions was observed. The influence of extract preparation condition and pH were also explored on the formation of AgNPs. Both selectivity and sensitivity differed for AgNPs synthesized from different parts of the plant. Direct correlation between the stability of green synthesized AgNPs at different pH and its antibacterial effects has been established. The selective colorimetric sensing of toxic metal ions and antimicrobial effect of green synthesized AgNPs demonstrated the multifunctional applications of green nanotechnology. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Liu, Juewen; Lu, Yi
This chapter reviews recent progress in the interface between functional nucleic acids and nanoscale science and technology, and its analytical applications. In particular, the use of metallic nanoparticles as the color reporting groups for the action (binding, catalysis, or both) of aptamers, DNAzymes, and aptazymes is described in detail. Because metallic nanoparticles possess high extinction coefficients and distance-dependent optical properties, they allow highly sensitive detections with minimal consumption of materials. The combination of quantum dots (QDs) with functional nucleic acids as fluorescent sensors is also described. The chapter starts with the design of colorimetric and fluorescent sensors responsive to single analytes, followed by sensors responsive to multiple analytes with controllable cooperativity and multiplex detection using both colorimetric and fluorescent signals in one pot, and ends by transferring solution-based detections into litmus paper type of tests, making them generally applicable and usable for a wide range of on-site and real-time analytical applications such as household tests, environmental monitoring, and clinical diagnostics.
No evidence for a direct role of HLA-B27 in pathological bone formation in axial SpA
Neerinckx, Barbara; Kollnberger, Simon; Shaw, Jacqueline; Lories, Rik
2017-01-01
Objective The strong genetic association between HLA-B27 and ankylosing spondylitis has been known for over 40 years. HLA-B27 positivity is possibly associated with severity of ankylosis. We studied the in vitro and in vivo impact of HLA-B27 in models of chondrogenesis and osteogenesis. Methods Different in vitro differentiation systems were used to mimic endochondral and direct bone formation. ATDC5 cells and primary human periosteum-derived cells (hPDCs) were transduced with lentiviral vectors expressing HLA-B27 or HLA-B7. These cells and limb bud cells (from HLA-B27 transgenic and wild-type (WT) mice) were cultured in micromasses. To study direct osteogenesis in hPDCs, cells were cultured as monolayers and stimulated with osteogenic media. Chondrogenesis (COL2, ACAN, COL10) and osteogenesis (OSC, ALP, RUNX2) marker expression was studied by quantitative RT-PCR. Colorimetric tests were performed to measure proteoglycans, mineralization and collagens. Collagen antibody-induced arthritis (CAIA) was induced in HLA-B27 transgenic and WT mice. Clinical scoring and µCTs were performed. Statistical analyses were performed by two-way ANOVA. Results There was no difference in chondrogenesis markers or in colorimetric tests between HLA-B27+ and HLA-B7+ micromasses. Expression of osteogenesis markers and Alizarin red staining was comparable in the HLA-B27+ and the HLA-B7+ hPDCs in monolayers. HLA-B27 transgenic mice showed more severe arthritis compared with WT mice in the CAIA model. µCT analysis showed no increased bone formation in HLA-B27 transgenic mice. Conclusion HLA-B27 seems to enhance joint inflammation in the CAIA model. We could not document a direct effect of HLA-B27 on chondrogenesis or osteogenesis. PMID:28879048
Silver nanoparticles-based colorimetric array for the detection of Thiophanate-methyl
NASA Astrophysics Data System (ADS)
Zheng, Mingda; Wang, Yingying; Wang, Chenge; Wei, Wei; Ma, Shuang; Sun, Xiaohan; He, Jiang
2018-06-01
A simple and selective colorimetric sensor based on citrate capped silver nanoparticles (Cit-AgNPs) is proposed for the detection of Thiophanate-methyl (TM) with high sensitivity and selectivity. The method based on the color change of Cit-AgNPs from yellow to cherry red with the addition of TM to Cit-AgNPs that caused a red-shift on the surface plasmon resonance (SPR) band from 394 nm to 525 nm due to the hydrogen-bonding and substitution. The density functional theory (DFT) method was also calculated the interactions between the TM and citrate ions. Under the optimized conditions, a linear relationship between the absorption ratio (A525nm/A394nm) and TM concentration was found in the range of 2-100 μM with correlation coefficient (R2) of 0.988. The detection limit of TM was 0.12 μM by UV-vis spectrometer. Moreover, the applicability of colorimetric sensor is successfully verified by the detection of TM in environmental samples with good recoveries.
NASA Astrophysics Data System (ADS)
Dóka, O.; Ajtony, Zs.; Bicanic, D.; Valinger, D.; Végvári, Gy.
2014-12-01
Carotenoids are important antioxidants found in various foods including those for nutrition of infants. In this investigation, the total carotenoid content (TCC) of nine different commercially available baby foods was quantified using colorimetric index * obtained via reflectance colorimetry (RC) and by laser photoacoustic spectroscopy (LPAS) at 473 nm. The latter requires a minimum of sample preparation and only a one time calibration step which enables practically direct quantification of TCC. Results were verified versus UV-Vis spectrophotometry (SP) as the reference technique. It was shown that RC and LPAS (at 473 nm) provide satisfactory results for *, = 0.9925 and = 0.9972, respectively. Other color indices do not show a correlation with TCC. When determining the TCC in baby foods containing tomatoes, it is necessary to select a different analytical wavelength to compensate for the effect of lycopene's presence in the test samples.
Antweiler, Ronald C.; Patton, Charles J.; Taylor, Howard E.
1996-01-01
The apparatus and methods used for the automatic, colorimetric determinations of dissolved nutrients (nitrate plus nitrite, nitrite, ammonium and orthophosphate) in natural waters are described. These techniques allow for the determination of nitrate plus nitrite for the concentration range 0.02 to 8 mg/L (milligrams per liter) as N (nitrogen); for nitrite, the range is 0.002 to 1.0 mg/L as N; for ammonium, the range is 0.006 to 2.0 mg/L as N; and for orthophosphate, the range is 0.002 to 1.0 mg/L as P (phosphorus). Data are presented that demonstrate the accuracy, precision and quality control of the methods.
An Improved Method for Determination of Cyanide Content in Bitter Almond Oil.
Chen, Jia; Liu, Lei; Li, Mengjun; Yu, Xiuzhu; Zhang, Rui
2018-01-01
An improved colorimetric method for determination of cyanide content in bitter almond oil was developed. The optimal determination parameters were as follows: volume ratio of hydrochloric acid to bitter almond oil (v/v), 1.5:1; holding time for hydrolysis, 120 min; and volume ratio of distillation solution to bitter almond oil (v/v), 8:1. Analytical results showed that the relative standard deviations (SDs) of determinations were less than 10%, which satisfies the test requirements. The results of high-performance liquid chromatography and measurements exhibited a significant correlation (R = 0.9888, SD = 0.2015). Therefore, the improved colorimetric method can be used to determine cyanide content in bitter almond oil.
Zhang, Decai; Wang, Weijia; Dong, Qian; Huang, Yunxiu; Wen, Dongmei; Mu, Yuejing; Yuan, Yong
2017-12-21
An isothermal colorimetric method is described for amplified detection of the CaMV 35S promoter sequence in genetically modified organism (GMO). It is based on (a) target DNA-triggered unlabeled molecular beacon (UMB) termini binding, and (b) exonuclease III (Exo III)-assisted target recycling, and (c) hemin/G-quadruplex (DNAzyme) based signal amplification. The specific binding of target to the G-quadruplex sequence-locked UMB triggers the digestion of Exo III. This, in turn, releases an active G-quadruplex segment and target DNA for successive hybridization and cleavage. The Exo III impellent recycling of targets produces numerous G-quadruplex sequences. These further associate with hemin to form DNAzymes and hence will catalyze H 2 O 2 -mediated oxidation of the chromogenic enzyme substrate ABTS 2- causing the formation of a green colored product. This finding enables a sensitive colorimetric determination of GMO DNA (at an analytical wavelength of 420 nm) at concentrations as low as 0.23 nM. By taking advantage of isothermal incubation, this method does not require sophisticated equipment or complicated syntheses. Analyses can be performed within 90 min. The method also discriminates single base mismatches. In our perception, it has a wide scope in that it may be applied to the detection of many other GMOs. Graphical abstract An isothermal and sensitive colorimetric method is described for amplified detection of CaMV 35S promoter sequence in genetically modified organism (GMO). It is based on target DNA-triggered molecular beacon (UMB) termini-binding and exonuclease III assisted target recycling, and on hemin/G-quadruplex (DNAzyme) signal amplification.
NASA Astrophysics Data System (ADS)
Wang, Jiasi; Wu, Li; Ren, Jinsong; Qu, Xiaogang
2014-01-01
We developed a novel telomere complementary (TC) oligonucleotide modified AuNP probe (TC-AuNPs) for colorimetric analysis of telomerase activity. The mechanism of this method is that the telomerase reaction products (TRP), which can hybridize with the TC-AuNPs, are able to protect the AuNPs from the aggregation induced by salt. It is demonstrated that the colorimetric method enabled the analysis of the telomerase activity in 1000 HeLa cells with the naked eye, and down to 100 HeLa cells with the aid of UV-Vis spectroscopy. This strategy is not only convenient and sensitive, but also has a tunable dynamic range. The platform is also applicable for the initial screening of a telomerase inhibitor to discover new anticancer drugs.We developed a novel telomere complementary (TC) oligonucleotide modified AuNP probe (TC-AuNPs) for colorimetric analysis of telomerase activity. The mechanism of this method is that the telomerase reaction products (TRP), which can hybridize with the TC-AuNPs, are able to protect the AuNPs from the aggregation induced by salt. It is demonstrated that the colorimetric method enabled the analysis of the telomerase activity in 1000 HeLa cells with the naked eye, and down to 100 HeLa cells with the aid of UV-Vis spectroscopy. This strategy is not only convenient and sensitive, but also has a tunable dynamic range. The platform is also applicable for the initial screening of a telomerase inhibitor to discover new anticancer drugs. Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr05185d
Patton, Charles J.; Kryskalla, Jennifer R.
2013-01-01
A multiyear research effort at the U.S. Geological Survey (USGS) National Water Quality Laboratory (NWQL) evaluated several commercially available nitrate reductase (NaR) enzymes as replacements for toxic cadmium in longstanding automated colorimetric air-segmented continuous-flow analyzer (CFA) methods for determining nitrate plus nitrite (NOx) in water. This research culminated in USGS approved standard- and low-level enzymatic reduction, colorimetric automated discrete analyzer NOx methods that have been in routine operation at the NWQL since October 2011. The enzyme used in these methods (AtNaR2) is a product of recombinant expression of NaR from Arabidopsis thaliana (L.) Heynh. (mouseear cress) in the yeast Pichia pastoris. Because the scope of the validation report for these new automated discrete analyzer methods, published as U.S. Geological Survey Techniques and Methods 5–B8, was limited to performance benchmarks and operational details, extensive foundational research with different enzymes—primarily YNaR1, a product of recombinant expression of NaR from Pichia angusta in the yeast Pichia pastoris—remained unpublished until now. This report documents research and development at the NWQL that was foundational to development and validation of the discrete analyzer methods. It includes: (1) details of instrumentation used to acquire kinetics data for several NaR enzymes in the presence and absence of known or suspected inhibitors in relation to reaction temperature and reaction pH; and (2) validation results—method detection limits, precision and bias estimates, spike recoveries, and interference studies—for standard- and low-level automated colorimetric CFA-YNaR1 reduction NOx methods in relation to corresponding USGS approved CFA cadmium-reduction (CdR) NOx methods. The cornerstone of this validation is paired sample statistical and graphical analysis of NOx concentrations from more than 3,800 geographically and seasonally diverse surface-water and groundwater samples that were analyzed in parallel by CFA-CdR and CFA enzyme-reduction methods. Finally, (3) demonstration of a semiautomated batch procedure in which 2-milliliter analyzer cups or disposable spectrophotometer cuvettes serve as reaction vessels for enzymatic reduction of nitrate to nitrite prior to analytical determinations. After the reduction step, analyzer cups are loaded onto CFA, flow injection, or discrete analyzers for simple, rapid, automatic nitrite determinations. In the case of manual determinations, analysts dispense colorimetric reagents into cuvettes containing post-reduction samples, allow time for color to develop, insert cuvettes individually into a spectrophotometer, and record percent transmittance or absorbance in relation to a reagent blank. Data presented here demonstrate equivalent analytical performance of enzymatic reduction NOx methods in these various formats to that of benchmark CFA-CdR NOx methods.
Effect of black point on accuracy of LCD displays colorimetric characterization
NASA Astrophysics Data System (ADS)
Li, Tong; Xie, Kai; He, Nannan; Ye, Yushan
2018-03-01
Black point is the point at which RGB's single channel digital drive value is 0. Due to the problem of light leakage of liquid-crystal displays (LCDs), black point's luminance value is not 0, this phenomenon bring some errors to colorimetric characterization of LCDs, especially low luminance value driving greater sampling effect. This paper describes the characteristic accuracy of polynomial model method and the effect of black point on accuracy, the color difference accuracy is given. When considering the black point in the characteristics equation, the maximum color difference is 3.246, the maximum color difference than without considering the black points reduced by 2.36. The experimental results show that the accuracy of LCDs colorimetric characterization can be improved, if the effect of black point is eliminated properly.
NASA Astrophysics Data System (ADS)
Abubaker, Mariam; Ngah, Che Wan Zanariah Che Wan; Ahmad, Musa; Kuswandi, Bambang
2018-06-01
A sensitive and selective colorimetric method has been developed for detection of Al3+ ion using 4-benzoyl pyrazolone-functionalized gold nanoparticles (BMPBP-AuNPs) as novel colorimetric probes. The BMPBP-AuNPs were characterized by UV-visible spectrometry and transmission electron microscopy (TEM). It was found that the addition of the Al3+ ions led to a rapid aggregation of the BMPBP-AuNPs, which changed the color of the mixture from red to blue. Furthermore, there was a shift in the characteristic surface plasmon resonance (SPR) peak from 524 to 650 nm of BMPBP-AuNPs, which confirmed that a good linear relation (R2 = 0.9935) was present between the absorption ratio of 524 and 650 nm. Also, the assay detected the Al3+ ion concentrations in the linear range 0-12 ppm with the detection limit is 0.05 ppm. Finally, the synthesized BMPBP-AuNPs were successfully used as a colorimetric sensor for the selective and sensitive detection of the Al3+ ions in water samples.
Mondal, Bhairab; Ramlal, Shylaja; Lavu, Padma S.; N, Bhavanashri; Kingston, Joseph
2018-01-01
A simple, sensitive and selective colorimetric biosensor for the detection of Staphylococcal enterotoxin B (SEB) was developed using SEB-binding aptamer (SEB2) as recognition element and unmodified gold nanoparticles (AuNPs) as colorimetric probes. The assay is based on color change from red to purple due to conformational change of aptamer in the presence of SEB, and the phenomenon of salt-induced AuNPs aggregation which could be monitored by naked eye or UV–vis spectrometer. Results showed that the AuNPs can effectively differentiate the SEB induced conformational change of the aptamer in the presence of a given high salt concentration. A linear response in the range of 50 μg/mL to 0.5 ng/mL of SEB concentration was obtained. The assay was highly specific to SEB as compared to other related toxins. The limit of detection (LOD) of SEB achieved within few minutes was 50 ng/mL visually and spectrometric method improved it to 0.5 ng/mL. Robustness of the assay was tested in artificially spiked milk samples and cross-checked using in house developed sandwich ELISA (IgY as capturing and SEB specific monoclonal as revealing antibody) and PCR. This colorimetric assay could be a suitable alternative over existing methods during biological emergencies due to its simplicity, sensitive and cost effectiveness. PMID:29487580
Bocanegra, Cristina; Gallego, Sara; Mendioroz, Jacobo; Moreno, Milagros; Sulleiro, Elena; Salvador, Fernando; Sikaleta, Nicolau; Nindia, Arlette; Tchipita, Daniel; Joromba, Morais; Kavaya, Sebastiao; Sánchez Montalvá, Adrián; López, Teresa; Molina, Israel
2015-01-01
Introduction Schistosomiasis remains a public health major problem and little is known in many areas, mainly in Sub-Saharan Africa Objectives To assess the burden and risk factors of schistosomiasis and intestinal parasitic helminthes in the children of Cubal, Angola, and to compare different diagnostic approaches for urinary schistosomiasis under field conditions. Methods A cross-sectional study was conducted. Urine and faeces samples of school children were microscopically studied. A random sample of children was obtained from an alphabetically arranged list of children, taking one of two children. Urine dipstick, colorimetric test and macrohaematuria were considered as indirect diagnostic methods and compared to direct urine examination. Possible risk factors for the infection were sex, age, distance to the river and previous treatment with praziquantel; the assessment was performed using Chi-square test. Results A total of 785 (61.18%) children showed S. haematobium eggs in urine; children living within 500 meters from the river had a higher odds for infection: Odds ratio 1.97 (1.45–2.7 CI 95%); urine dipstick showed sensitivity of 96% and specificity of 61.3%, with a positive predictive value; colorimetric test showed sensitivity of 52.5%, specificity of 74.6% and a positive predictive value of 77%. Proteinuria was present in 653 (51.1%) children, being more frequent in children with S. haematobium in urine (75.2%); 32 of 191 stool samples (16%) showed the presence of other intestinal parasites and 8 (4%) for S. haematobium. Conclusions Prevalence of urinary schistosomiasis in our study area is much higher than the national average, considering it as a high-risk community. Proximity to a source of water was a risk factor for the infection. Indirect tests, as urine dipstick and colorimetric test, were useful tools for diagnosis, due to ease of use and low cost. Proteinuria was a common finding, probably showing an early structural damage due to schistosomiasis in this group of children. PMID:26474169
Russell, Steven M; Doménech-Sánchez, Antonio; de la Rica, Roberto
2017-06-23
Colorimetric tests are becoming increasingly popular in point-of-need analyses due to the possibility of detecting the signal with the naked eye, which eliminates the utilization of bulky and costly instruments only available in laboratories. However, colorimetric tests may be interpreted incorrectly by nonspecialists due to disparities in color perception or a lack of training. Here we solve this issue with a method that not only detects colorimetric signals but also interprets them so that the test outcome is understandable for anyone. It consists of an augmented reality (AR) app that uses a camera to detect the colored signals generated by a nanoparticle-based immunoassay, and that yields a warning symbol or message when the concentration of analyte is higher than a certain threshold. The proposed method detected the model analyte mouse IgG with a limit of detection of 0.3 μg mL -1 , which was comparable to the limit of detection afforded by classical densitometry performed with a nonportable device. When adapted to the detection of E. coli, the app always yielded a "hazard" warning symbol when the concentration of E. coli in the sample was above the infective dose (10 6 cfu mL -1 or higher). The proposed method could help nonspecialists make a decision about drinking from a potentially contaminated water source by yielding an unambiguous message that is easily understood by anyone. The widespread availability of smartphones along with the inexpensive paper test that requires no enzymes to generate the signal makes the proposed assay promising for analyses in remote locations and developing countries.
Tian, Kun; Siegel, Gene; Tiwari, Ashutosh
2017-02-01
The development of simple and cost-effective methods for the detection and treatment of Hg 2+ in the environment is an important area of research due to the serious health risk that Hg 2+ poses to humans. Colorimetric sensing based on the induced aggregation of nanoparticles is of great interest since it offers a low cost, simple, and relatively rapid procedure, making it perfect for on-site analysis. Herein we report the development of a simple colorimetric sensor for the selective detection and estimation of mercury ions in water, based on chitosan stabilized gold nanoparticles (AuNPs) and 2,6-pyridinedicarboxylic acid (PDA). In the presence of Hg 2+ , PDA induces the aggregation of AuNPs, causing the solution to change colors varying from red to blue, depending on the concentration of Hg 2+ . The formation of aggregated AuNPs in the presence of Hg 2+ was confirmed using transmission electron microscopy (TEM) and UV-Vis spectroscopy. The method exhibits linearity in the range of 300nM to 5μM and shows excellent selectivity towards Hg 2+ among seventeen different metal ions and was successfully applied for the detection of Hg 2+ in spiked river water samples. The developed technique is simple and superior to the existing techniques in that it allows detection of Hg 2+ using the naked eye and simple and rapid colorimetric analysis, which eliminates the need for sophisticated instruments and sample preparation methods. Copyright © 2016 Elsevier B.V. All rights reserved.
Kumar, Anshu; Bhatt, Madhuri; Vyas, Gaurav; Bhatt, Shreya; Paul, Parimal
2017-05-24
A sunlight induced simple green route has been developed for the synthesis of polyacrylate functionalized gold nanoparticles (PAA-AuNPs), in which poly(acrylic acid) functions as a reducing as well as stabilizing agent. This material has been characterized on the basis of spectroscopic and microscopic studies; it exhibited selective colorimetric detection of Al 3+ in aqueous media, and the Al 3+ induced aggregated PAA-AuNPs exhibited detection of F - with sharp color change and high selectivity and sensitivity out of a large number of metal ions and anions tested. The mechanistic study revealed that, for Al 3+ , the color change is due to a shift of the SPR band because of the Al 3+ induced aggregation of PAA-AuNPs, whereas for F - , the reverse color change (blue to red) with return of the SPR band to its original position is due to dispersion of aggregated PAA-AuNPs, as F - removes Al 3+ from the aggregated species by complex formation. Only concentration-dependent fluoride ion can prevent Al 3+ from aggregating PAA-AuNPs. The method is successfully used for the detection of F - in water collected from various sources by the spiking method, in toothpastes of different brands by the direct method. The solid Al 3+ -PAA-AuNPs were isolated, adsorbed on ZIF@8 (zeolitic imidazolate framework) and on a cotton strip, and applied as solid sensing material for detection of F - in aqueous media.
Pitfalls in the detection of cholesterol in Huntington's disease models.
Marullo, Manuela; Valenza, Marta; Leoni, Valerio; Caccia, Claudio; Scarlatti, Chiara; De Mario, Agnese; Zuccato, Chiara; Di Donato, Stefano; Carafoli, Ernesto; Cattaneo, Elena
2012-10-11
Background Abnormalities in brain cholesterol homeostasis have been reported in Huntington's disease (HD), an adult-onset neurodegenerative disorder caused by an expansion in the number of CAG repeats in the huntingtin (HTT) gene. However, the results have been contradictory with respect to whether cholesterol levels increase or decrease in HD models. Biochemical and mass spectrometry methods show reduced levels of cholesterol precursors and cholesterol in HD cells and in the brains of several HD animal models. Abnormal brain cholesterol homeostasis was also inferred from studies in HD patients. In contrast, colorimetric and enzymatic methods indicate cholesterol accumulation in HD cells and tissues. Here we used several methods to investigate cholesterol levels in cultured cells in the presence or absence of mutant HTT protein. Results Colorimetric and enzymatic methods with low sensitivity gave variable results, whereas results from a sensitive analytical method, gas chromatography-mass spectrometry, were more reliable. Sample preparation, high cell density and cell clonality also influenced the detection of intracellular cholesterol. Conclusions Detection of cholesterol in HD samples by colorimetric and enzymatic assays should be supplemented by detection using more sensitive analytical methods. Care must be taken to prepare the sample appropriately. By evaluating lathosterol levels using isotopic dilution mass spectrometry, we confirmed reduced cholesterol biosynthesis in knock-in cells expressing the polyQ mutation in a constitutive or inducible manner. *Correspondence should be addressed to Elena Cattaneo: elena.cattaneo@unimi.it.
A simple and highly sensitive colorimetric detection method for gaseous formaldehyde.
Feng, Liang; Musto, Christopher J; Suslick, Kenneth S
2010-03-31
A colorimetric detection method using amine-functionalized polymer films doped with a pH indicator has been developed for the rapid, sensitive, and quantitative detection of gaseous formaldehyde at concentrations well below the immediately dangerous to life or health (IDLH) limit. In 1 min, visible color changes are easily observed, even down to the permissible exposure limit (PEL) at 750 ppb. The limit of detection is below 50 ppb (7% of the PEL) after 10 min of exposure. This sensor is essentially unaffected by changes in humidity or temperature (4 to 50 degrees C) and is not sensitive to common interferents.
NASA Astrophysics Data System (ADS)
Rohit, Jigneshkumar V.; Kailasa, Suresh Kumar
2014-11-01
We have developed a simple and rapid colorimetric method for on-site analysis of thiram and paraquat using cyclen dithiocarbamate-functionalized silver nanoparticles (CN-DTC-Ag NPs) as a colorimetric probe. The synthesized CN-DTC-Ag NPs were characterized by UV-Visible spectroscopy (UV-Vis), Fourier transform infrared spectroscopy, dynamic light scattering, and transmission electron microscopic techniques. The CN-DTC molecules provide good supramolecular self assembly on the surfaces of Ag NPs to encapsulate thiram and paraquat selectively via "host-guest" chemistry, resulting in red-shift in surface plasmon resonance peak of CN-DTC-Ag NPs from 396 to 530 nm and 510 nm and color change from yellow to pink for thiram and to orange for paraquat, which can be naked-eye detected. The present method shows good linearity in the range of 10.0-20.0 µM and of 50.0-250 µM with limits of detection 2.81 × 10-6 M and 7.21 × 10-6 M for thiram and paraquat, respectively. This method was proved as a promising tool for on-site and real-time monitoring of thiram and paraquat in environmental water, potato, and wheat samples.
Ahn, Junho; Choi, Yeonweon; Lee, Ae-Ree; Lee, Joon-Hwa; Jung, Jong Hwa
2016-03-21
Using duplex DNA-AuNP aggregates, a sequence-specific DNA-binding protein, SQUAMOSA Promoter-binding-Like protein 12 (SPL-12), was directly determined by SPL-12-duplex DNA interaction-based colorimetric actions of DNA-Au assemblies. In order to prepare duplex DNA-Au aggregates, thiol-modified DNA 1 and DNA 2 were attached onto the surface of AuNPs, respectively, by the salt-aging method and then the DNA-attached AuNPs were mixed. Duplex-DNA-Au aggregates having the average size of 160 nm diameter and the maximum absorption at 529 nm were able to recognize SPL-12 and reached the equivalent state by the addition of ∼30 equivalents of SPL-12 accompanying a color change from red to blue with a red shift of the maximum absorption at 570 nm. As a result, the aggregation size grew to about 247 nm. Also, at higher temperatures of the mixture of duplex-DNA-Au aggregate solution and SPL-12, the equivalent state was reached rapidly. On the contrary, in the control experiment using Bovine Serum Albumin (BSA), no absorption band shift of duplex-DNA-Au aggregates was observed.
NASA Astrophysics Data System (ADS)
Nopwinyuwong, Atchareeya; Kitaoka, Takuya; Boonsupthip, Waraporn; Pechyen, Chiravoot; Suppakul, Panuwat
2014-09-01
Polydiacetylene (PDA)/silica nanocomposites were synthesized by self-assembly method using polymerizable amphiphilic diacetylene monomers, 10,12-pentacosadiynoic acid (PCDA). Addition of cationic surfactants (PDADMAC and CTAB) to PDA/SiO2 nanocomposites induced higher intermolecular force which affected their size, shape and color transition. Pure PDA, PDA/SiO2, PDA/SiO2/PDADMAC and PDA/SiO2/CTAB were investigated by particle size analysis, TEM, SEM, UV-vis spectroscopy and FT-IR. It was found that the PDA/SiO2 nanocomposites exhibited slightly larger particle sizes than those of other samples. The PDA/SiO2 nanocomposites with a core-shell structure were almost regarded as spherical-shaped particles. Cationic surfactants, especially CTAB, presumably affected the particle size and shape of PDA/SiO2 nanocomposites due to the disruption of hydrogen bonding between PDA head group and ammonium group. The colorimetric response of both PDA/SiO2/surfactant and surfactant-free PDA/SiO2 aqueous solutions directly changed in relation to time and temperature; thus they were expected to be applied as a new polymer-based time-temperature indicator (TTI).
Houk, Ronald J. T.; Wallace, Karl J.; Hewage, Himali S.; Anslyn, Eric V.
2008-01-01
A colorimetric chemodosimeter (SQ1) for the detection of trace palladium salts in cross-coupling reactions mediated by palladium is described. Decolorization of SQ1 is affected by nucleophilic attack of ethanethiol in basic DMSO solutions. Thiol addition is determined to have an equilibrium constant (Keq) of 2.9 × 106 M-1, with a large entropic and modest enthalpic driving force. This unusual result is attributed to solvent effects arising from a strong coordinative interaction between DMSO and the parent squaraine. Palladium detection is achieved through thiol scavenging from the SQ1-ethanethiol complex leading to a color “turn-on” of the parent squaraine. It was found that untreated samples obtained directly from Suzuki couplings showed no response to the assay. However, treatment of the samples with aqueous nitric acid generates a uniform Pd(NO3)2 species, which gives an appropriate response. “Naked-eye” detection of Pd(NO3)2 was estimated to be as low as 0.5 ppm in solution, and instrument-based detection was tested as low as 100 ppb. The average error over the working range of the assay was determined to be 7%. PMID:19122841
A Colorimetric Microplate Assay for DNA-Binding Activity of His-Tagged MutS Protein.
Banasik, Michał; Sachadyn, Paweł
2016-09-01
A simple microplate method was designed for rapid testing DNA-binding activity of proteins. The principle of the assay involves binding of tested DNA by his-tagged protein immobilized on a nickel-coated ELISA plate, following colorimetric detection of biotinylated DNA with avidin conjugated to horseradish peroxidase. The method was used to compare DNA mismatch binding activities of MutS proteins from three bacterial species. The assay required relatively low amounts of tested protein (approximately 0.5-10 pmol) and DNA (0.1-10 pmol) and a relatively short time of analysis (up to 60 min). The method is very simple to apply and convenient to test different buffer conditions of DNA-protein binding. Sensitive colorimetric detection enables naked eye observations and quantitation with an ELISA reader. The performance of the assay, which we believe is a distinguishing trait of the method, is based on two strong and specific molecular interactions: binding of a his-tagged protein to a nickel-coated microplate and binding of biotinylated DNA to avidin. In the reported experiments, the solution was used to optimize the conditions for DNA mismatch binding by MutS protein; however, the approach could be implemented to test nucleic acids interactions with any protein of interest.
Mandal, Shreya; Patra, Arpita; Samanta, Animesh; Roy, Suchismita; Mandal, Arpita; Mahapatra, Tapasi Das; Pradhan, Shrabani; Das, Koushik; Nandi, Dilip Kumar
2013-12-01
To investigate phytochemical screening, antimicrobial activity and qualitative thin layer chromatographic separation of flavonoid components, antioxidant activity and total flavonoid compound of Terminalia arjuna. For phytochemical screening, some common and available standard tests were done. Antimicrobial bioassay was done through agar well diffusion method. Detection of antioxidant activity and flavonoid compounds were done through thin layer chromatography. Total antioxidant activity was measured by 2, 2-diphenyl-1-picrylhydrazyl (DPPH) in colorimetric method. Aluminum chloride colorimetric method was used for total flavonoid determination. Phytochemical screening showed the active compounds presence in high concentration, such as phytosterol, lactones, flavonoids, phenolic compounds and tannins and glycosides. The antimicrobial activity of extract showed that greater inhibition zone against Gram negative bacteria than Gram positive bacteria. This methanolic extract showed a promising antioxidant activity, as absorption of DPPH redicles decreased in DPPH free radical scavenging assay. Flavonoids components having antioxidant property present in the methanol extract at a level of 199.00 mg quercetin equivalent/g of dried methanol extract in colorimetric method. The Terminalia arjuna bark extract revealed the presence of bio-active constituents which are known to exhibit medicinal as well as physiological activities. Copyright © 2013 Asian Pacific Tropical Biomedical Magazine. Published by Elsevier B.V. All rights reserved.
[Research on the designing method of a special shade guide for tooth whitening].
Xu, Yingxin
2015-10-01
To investigate a method of designing an accurate and scientific shade guide, especially used for judging the effect of tooth whitening, by analyzing the colorimetric values of discolored teeth statistically. One hundred thirty-six pictures of patients who had been receiving the Beyond cold light whitening treatment from February 2009 to July 2014 were analyzed, including 25 tetracycline teeth, 61 mottled-enamel teeth, and 50 yellow teeth. The colorimetric values of discolored teeth were measured. The L* values of shade tabs were calculated by hierarchical clustering of those of discolored teeth. The a* and b* values of shade tabs were the mean of those observed for discolored teeth. Accordingly, different shade guides were designed for each type of discolored teeth, and the effects were evaluated. A statistically significant difference in colorimetric values was found among the three types of discolored teeth. Compared with the Vitapan Classical shade guide, the shade guides designed through the present method were more scientific and accurate in judging the effect of tooth whitening. Moreover, the arrangement of shade tabs was more logical, and the color difference between shade tabs and discolored teeth was smaller. The proposed designing method is theoretically feasible, although its clinical effect has yet to be proven.
Levent, Abdulkadir; Sentürk, Zühre
2010-09-01
Colorimetric and atomic absorption spectrometric methods have been developed for the determination of mucolytic drug Ambroxol. These procedures depend upon the reaction of iron(III) metal ion with the drug in the presence of thiocyanate ion to form stable ion-pair complex which extractable chloroform. The red-coloured complex was determined either colorimetrically at 510 nm or by indirect atomic absorption spectrometry (AAS) via the determination of the iron content in the formed complex. The optimum experimental conditions for pH, concentrations of Fe(3+) and SCN(-), shaking time, phase ratio, and the number of extractions were determined. Under the proposed conditions, linearity was obeyed in the concentration ranges 4.1x10(-6) - 5.7x10(-5) M (1.7-23.6 µg mL(-1)) using both methods, with detection limits of 4.6x10(-7) M (0.19 µg mL(-1)) for colorimetry and 1.1x10(-6) M (0.46 µg mL(-1)) for AAS. The proposed methods were applied for the determination of Ambroxol in tablet dosage forms. The results obtained were statistically analyzed and compared with those obtained by applying the high-performance liquid chromatographic method with diode-array detection.
Martinez, Andres W; Phillips, Scott T; Carrilho, Emanuel; Thomas, Samuel W; Sindi, Hayat; Whitesides, George M
2008-05-15
This article describes a prototype system for quantifying bioassays and for exchanging the results of the assays digitally with physicians located off-site. The system uses paper-based microfluidic devices for running multiple assays simultaneously, camera phones or portable scanners for digitizing the intensity of color associated with each colorimetric assay, and established communications infrastructure for transferring the digital information from the assay site to an off-site laboratory for analysis by a trained medical professional; the diagnosis then can be returned directly to the healthcare provider in the field. The microfluidic devices were fabricated in paper using photolithography and were functionalized with reagents for colorimetric assays. The results of the assays were quantified by comparing the intensities of the color developed in each assay with those of calibration curves. An example of this system quantified clinically relevant concentrations of glucose and protein in artificial urine. The combination of patterned paper, a portable method for obtaining digital images, and a method for exchanging results of the assays with off-site diagnosticians offers new opportunities for inexpensive monitoring of health, especially in situations that require physicians to travel to patients (e.g., in the developing world, in emergency management, and during field operations by the military) to obtain diagnostic information that might be obtained more effectively by less valuable personnel.
Xu, Yunbo; Dong, Yangjun; Jiang, Xue; Zhu, Ningning
2013-10-01
This study describes a simple and highly selective method for the colorimetric detection of trivalent chromium (Cr3+) using tartrate-capped silver nanoparticles (AgNPs) as probe. The addition of tartrate to the initially prepared AgNPs gives tartrate-stabilized AgNPs ascribing to the electrostatic repulsion of the highly negatively charged tartrate ions covered on the surface of AgNPs. It is found that, in the presence of Cr3+ in aqueous solution, the aggregation of tartrate-stabilized AgNPs occurs. The color of AgNPs suspension changes from yellow to pink and the surface plasmon absorption band broadens and red shifts, which could be applied for the colorimetric detection of Cr3+ in aqueous solution. The utilization of tartrate-stabilized AgNPs as probe substantially increases the selectivity and sensitivity for colorimetric detection of Cr3+. Control experiments with the addition of over 14 other metal ions, such as Pb2+, Zn2+, Cr2O7(2-), Cd2+, Co2+, Cu2+, Al3+, Ni2+, Mn2+, Ba2+, Fe3+, Ca2+, Mg2+, Sr+ do not result in a distinct change in the color or in the spectrum of the suspension, indicating that these metal ions do not interfere with the colorimetric detection of Cr3+. Under the conditions employed here, A502/A393 (ratio of absorption value at 502 nm to 393 nm) is linear with the concentration of Cr3+ within a concentration range from 0.1 to 1.17 microM with a detection limit of 0.06 microM. This study may offer a simple, rapid and sensitive approach to colorimetric detection of Cr3+ in aqueous solution.
Jahn, B; Stüben, A; Bhakdi, S
1996-01-01
Two colorimetric methods that use Alamar Blue or 3-(4,5-dimethyl-2-thiazolyl)-2,5-diphenyl-2H-tetrazolium bromide (MTT) for assaying the in vitro activities of antifungal agents have been described. We report that both tests performed similarly when the antifungal activity of amphotericin B against Candida albicans was determined. However, only the MTT test generated interpretable data when Aspergillus fumigatus was used. PMID:8818910
Chen, Yuan; Fu, Qiangqiang; Li, Dagang; Xie, Jun; Ke, Dongxu; Song, Qifang; Tang, Yong; Wang, Hong
2017-11-01
Smartphone biosensors could be cost-effective, portable instruments to be used for the readout of liquid colorimetric assays. However, current reported smartphone colorimetric readers have relied on photos of liquid assays captured using a camera, and then analyzed using software programs. This approach results in a relatively low accuracy and low generality. In this work, we reported a novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays. The portable and low-cost ($0.15) reader utilized a simplified electronic and light path design. Furthermore, our reported smartphone colorimetric reader can be compatible with different smartphones. As a proof of principle, the utility of this device was demonstrated using it in conjunction with an enzyme-linked immunosorbent assay to detect zearalenone. Results were consistent with those obtained using a professional microplate reader. The developed smartphone colorimetric reader was capable of providing scalable, cost-effective, and accurate results for liquid colorimetric assays that related to clinical diagnoses, environment pollution, and food testing. Graphical abstract A novel smartphone colorimetric reader that has been integrated with an ambient light sensor and a 3D printed attachment for the readout of liquid colorimetric assays.
An improved method for LCD displays colorimetric characterization
NASA Astrophysics Data System (ADS)
Li, Tong; Xie, Kai; Wang, Qiaojie; He, Nannan; Ye, Yushan
2018-03-01
The colorimetric characterization of the display can achieve the purpose of precisely controlling the color of the monitor. This paper describes an improved method for estimating the gamma value of liquid-crystal displays (LCDs) without using a measurement device was described by Xiao et al. It relies on observer's luminance matching by presenting eight half-tone patterns with luminance from 1/9 to 8/9 of the maximum value of each color channel. Since the previous method lacked partial low frequency information, we partially replaced the half-tone patterns. A large number of experiments show that the color difference is reduced from 3.726 to 2.835, and our half-tone pattern can better estimate the visual gamma value of LCDs.
Enzyme-free colorimetric detection systems based on the DNA strand displacement competition reaction
NASA Astrophysics Data System (ADS)
Zhang, Z.; Birkedal, V.; Gothelf, K. V.
2016-05-01
The strand displacement competition assay is based on the dynamic equilibrium of the competitive hybridization of two oligonucleotides (A and B) to a third oligonucleotide (S). In the presence of an analyte that binds to a specific affinity-moiety conjugated to strand B, the equilibrium shifts, which can be detected by a shift in the fluorescence resonance energy transfer signal between dyes attached to the DNA strands. In the present study we have integrated an ATP aptamer in the strand B and demonstrated the optical detection of ATP. Furthermore we explore a new readout method using a split G-quadruplex DNAzyme for colorimetric readout of the detection of streptavidin by the naked eye. Finally, we integrate the whole G-quadruplex DNAzyme system in a single DNA strand and show that it is applicable to colorimetric detection.
The Disassembly of a Core-Satellite Nanoassembled Substrate for Colorimetric Biomolecular Detection
Waldeisen, John R.; Wang, Tim; Ross, Benjamin M.; Lee, Luke P.
2012-01-01
The disassembly of a core-satellite nanostructured substrate is presented as a colorimetric biosensor observable under dark field illumination. The fabrication method described herein utilizes thiol-mediated adsorption and streptavidin-biotin binding to self-assemble core-satellite nanostructures with a sacrificial linking peptide. Biosensing functionality is demonstrated with the protease trypsin and the optical properties of the nanoassemblies are characterized. A figure of merit is presented to determine the optimal core and satellite size for visual detection. Nanoassemblies with 50 nm cores and 30 nm or 50 nm satellites are superior as these structures achieve an orange to green color shift greater than 70 nm that is easily discernible by naked eye. This colorimetric substrate may prove to be a favorable alternative to liquid-based colloidal sensors and a useful visual readout mechanism for microfluidic diagnostic assays. PMID:21667984
Colour change evaluation on UV radiation exposure for Păun-Repedea calcareous geomaterial
NASA Astrophysics Data System (ADS)
Pelin, V.; Sandu, I.; Munteanu, M.; Iurcovschi, C. T.; Gurlui, S.; Sandu, AV; Vasilache, V.; Brȃnzilă, M.; Sandu, I. G.
2016-06-01
When talking about the preservation treatments that can be applied to natural stones used in different constructions, the surface hydrophobization plays an important part, especially when referring to porous surfaces like the calcareous oolithic stones specific to Repedea area, Iasi County, Romania. The present paper presents a method that evaluates the hydrophobization efficiency of two types of pellicles, involving UV artificial ageing and colorimetric analysis of the treated surfaces. The evaluation was done through continuous colorimetric monitoring and by comparing the evolution of the chromatic modifications of the two treated surfaces with the original colorimetric values and with the witness area, which was exposed to UV radiations under the same conditions, but left chemical untreated. The techniques used during this experiment were: CIE L*a*b* colorimetry, OM, SEM-EDX, UV radiation exposure and Spectrum Irradiance Measurement.
A colorimetric sensor array for detection of triacetone triperoxide vapor.
Lin, Hengwei; Suslick, Kenneth S
2010-11-10
Triacetone triperoxide (TATP), one of the most dangerous primary explosives, has emerged as an explosive of choice for terrorists in recent years. Owing to the lack of UV absorbance, fluorescence, or facile ionization, TATP is extremely difficult to detect directly. Techniques that are able to detect generally require expensive instrumentation, need extensive sample preparation, or cannot detect TATP in the gas phase. Here we report a simple and highly sensitive colorimetric sensor for the detection of TATP vapor with semiquantitative analysis from 50 ppb to 10 ppm. By using a solid acid catalyst to pretreat a gas stream, we have discovered that a colorimetric sensor array of redox sensitive dyes can detect even very low levels of TATP vapor from its acid decomposition products (e.g., H(2)O(2)) with limits of detection (LOD) below 2 ppb (i.e., <0.02% of its saturation vapor pressure). Common potential interferences (e.g., humidity, personal hygiene products, perfume, laundry supplies, volatile organic compounds, etc.) do not generate an array response, and the array can also differentiate TATP from other chemical oxidants (e.g., hydrogen peroxide, bleach, tert-butylhydroperoxide, peracetic acid).
Hu, Qinqin; Fu, Yingchun; Xu, Xiahong; Qiao, Zhaohui; Wang, Ronghui; Zhang, Ying; Li, Yanbin
2016-02-07
Acrylamide (AA), a neurotoxin and a potential carcinogen, has been found in various thermally processed foods such as potato chips, biscuits, and coffee. Simple, cost-effective, and sensitive methods for the rapid detection of AA are needed to ensure food safety. Herein, a novel colorimetric method was proposed for the visual detection of AA based on a nucleophile-initiated thiol-ene Michael addition reaction. Gold nanoparticles (AuNPs) were aggregated by glutathione (GSH) because of a ligand-replacement, accompanied by a color change from red to purple. In the presence of AA, after the thiol-ene Michael addition reaction between GSH and AA with the catalysis of a nucleophile, the sulfhydryl group of GSH was consumed by AA, which hindered the subsequent ligand-replacement and the aggregation of AuNPs. Therefore, the concentration of AA could be determined by the visible color change caused by dispersion/aggregation of AuNPs. This new method showed high sensitivity with a linear range from 0.1 μmol L(-1) to 80 μmol L(-1) and a detection limit of 28.6 nmol L(-1), and especially revealed better selectivity than the fluorescence sensing method reported previously. Moreover, this new method was used to detect AA in potato chips with a satisfactory result in comparison with the standard methods based on chromatography, which indicated that the colorimetric method can be expanded for the rapid detection of AA in thermally processed foods.
Hijaz, Faraj; Killiny, Nabil
2016-05-20
Delta-aminolevulinic (δ-ALA) acid is an important intermediate for tetrapyrroles biosynthesis and it has recently received great attention in plant physiology and human toxicology. However, the colorimetric method which is the most common method for determination of δ-ALA is time consuming and is not specific. In this study, a method for determination of δ-ALA in plant tissues was developed based on the trimethylsilyl (TMS) derivative of the pyrrole formed from the reaction of δ-ALA with ethyl acetoacetate via Knorr condensation. The δ-ALA in the HCl extract was reacted with ethyl acetoacetate to form a pyrrole. Then, the pyrrole compound was extracted using ethyl acetate and the solvent was evaporated to dryness. The dried sample was derivatized to its TMS ester and analyzed using GC-MS. The concentration of δ-ALA in citrus leaves incubated with levulinic acid was also determined by the conventional colorimetric method. The linear range was 10-200ppm in the full scan mode and 0.1-20ppm in the selected ion monitoring (SIM). The limit of detection was 6ppm in the full scan and 0.05ppm in SIM mode, representing a four-fold increase in sensitivity compared to the colorimetric method. The GC-MS method developed in this study is simple, accurate, sensitive, and could also be used to measure δ-ALA in other biological samples. Copyright © 2016 Elsevier B.V. All rights reserved.
Rana, Muhit; Balcioglu, Mustafa; Robertson, Neil M.; Hizir, Mustafa Salih; Yumak, Sumeyra
2017-01-01
The EPA's recommended maximum allowable level of inorganic mercury in drinking water is 2 ppb (10 nM). To our knowledge, the most sensitive colorimetric mercury sensor reported to date has a limit of detection (LOD) of 800 pM. Here, we report an instrument-free and highly practical colorimetric methodology, which enables detection of as low as 2 ppt (10 pM) of mercury and/or silver ions with the naked eye using a gold nanoprobe. Synthesis of the nanoprobe costs less than $1.42, which is enough to perform 200 tests in a microplate; less than a penny for each test. We have demonstrated the detection of inorganic mercury from water, soil and urine samples. The assay takes about four hours and the color change is observed within minutes after the addition of the last required element of the assay. The nanoprobe is highly programmable which allows for the detection of mercury and/or silver ions separately or simultaneously by changing only a single parameter of the assay. This highly sensitive approach for the visual detection relies on the combination of the signal amplification features of the hybridization chain reaction with the plasmonic properties of the gold nanoparticles. Considering that heavy metal ion contamination of natural resources is a major challenge and routine environmental monitoring is needed, yet time-consuming, this colorimetric approach may be instrumental for on-site heavy metal ion detection. Since the color transition can be measured in a variety of formats including using the naked eye, a simple UV-Vis spectrophotometer, or recording using mobile phone apps for future directions, our cost-efficient assay and method have the potential to be translated into the field. PMID:28451261
Wang, Yanying; Yang, Yan; Liu, Wei; Ding, Fang; Zhao, Qingbiao; Zou, Ping; Wang, Xianxiang; Rao, Hanbing
2018-05-04
A dual-read detection system is described for non-enzymatic and non-aggregation based analysis of uric acid (UA). Silver triangular nanoprisms (AgTNPs) were used as colorimetric probes, while the reduction in the fluorescence of nitrogen-doped carbon quantum dots (N-CQDs) served as the fluorometric readout. The absorption band of the AgTNPs overlaps the emission band of N-CQDs (with a peak at 440 nm). Therefore, fluorescence is reduced owing to an inner filter effect. The AgTNPs are etched if exposed to H 2 O 2 , and round nanodiscs are formed. In the presence of UA, etching of the AgTNPs is suppressed because the facets of the AgTNPs are coated with UA. The absorbance, best measured at 683 nm, increases with the concentration of the pre-added UA. The colorimetric assay works in the 0.1-45 μM UA concentration range, and the fluorometric assay between 1 and 42 μM of UA. The respective detection limits are 50 and 200 nM, respectively. The probe can be used for direct visualization of UA. The method was successfully applied to the determination of UA in urine samples. Graphical abstract The fluorescence of nitrogen-doped carbon quantum dots (N-CQDs) is quenched by AgTNPs (silver triangular nanoprisms). As the AgTNPs are etched by H 2 O 2 , fluorescence recovers in the system after H 2 O 2 is added, and also undergoes a color change. Uric acid (UA) protects the AgTNPs from etching because the facets of the AgTNPs are coated with UA. The fluorescence of N-CQDs decreases. Thus, a dual-read probe is developed for determination of UA.
Colorimetric detection of endogenous hydrogen sulfide production in living cells
NASA Astrophysics Data System (ADS)
Ahn, Yong Jin; Lee, Young Ju; Lee, Jaemyeon; Lee, Doyeon; Park, Hun-Kuk; Lee, Gi-Ja
2017-04-01
Hydrogen sulfide (H2S) has received great attention as a third gaseous signal transmitter, following nitric oxide and carbon monoxide. In particular, H2S plays an important role in the regulation of cancer cell biology. Therefore, the detection of endogenous H2S concentrations within biological systems can be helpful to understand the role of gasotransmitters in pathophysiology. Although a simple and inexpensive method for the detection of H2S has been developed, its direct and precise measurement in living cells remains a challenge. In this study, we introduced a simple, facile, and inexpensive colorimetric system for selective H2S detection in living cells using a silver-embedded Nafion/polyvinylpyrrolidone (PVP) membrane. This membrane could be easily applied onto a polystyrene microplate cover. First, we optimized the composition of the coating membrane, such as the PVP/Nafion mixing ratio and AgNO3 concentration, as well as the pH of the Na2S (H2S donor) solution and the reaction time. Next, the in vitro performance of a colorimetric detection assay utilizing the silver/Nafion/PVP membrane was evaluated utilizing a known concentration of Na2S standard solution both at room temperature and at 37 °C in a 5% CO2 incubator. As a result, the sensitivity of the colorimetric assay for H2S at 37 °C in the incubator (0.0056 Abs./μM Na2S, R2 = 0.9948) was similar to that at room temperature (0.0055 Abs./μM Na2S, R2 = 0.9967). Moreover, these assays were less sensitive to interference from compounds such as glutathione, L-cysteine (Cys), and dithiothreitol than to the H2S from Na2S. This assay based on the silver/Nafion/PVP membrane also showed excellent reproducibility (2.8% RSD). Finally, we successfully measured the endogenous H2S concentrations in live C6 glioma cells by s-(5‧-adenosyl)-L-methionine stimulation with and without Cys and L-homocysteine, utilizing the silver/Nafion/PVP membrane. In summary, colorimetric assays using silver/Nafion/PVP-coated membranes can be simple, robust, and reliable tools for the detection of H2S that can avoid the complicated and labor-intensive analytical approach used in conventional biology. In addition, we expect that this assay will demonstrate a powerful ability to study pathophysiological pathways that involve H2S.
NASA Astrophysics Data System (ADS)
R. S., Aparna; J. S., Anjali Devi; John, Nebu; Abha, K.; S. S., Syamchand; George, Sony
2018-06-01
Hurdles to develop point of care diagnostic methods restrict the translation of progress in the health care sector from bench side to bedside. In this article a simple, cost effective fluorescent as well as colorimetric nanosensor was developed for the early and easy detection of hyperbilirubinemia. A stable, water soluble bovine serum albumin stabilised copper nanocluster (BSA CuNC) was used as the fluorescent probe which exhibited strong blue emission (404 nm) upon 330 nm excitation. The fluorescence of the BSA CuNC can be effectively quenched by the addition of bilirubin by the formation of copper-bilirubin complex. Meanwhile the copper-bilirubin complex resulted in an observable colour change from pale violet to green facilitating colorimetric detection. The prepared sensor displayed good selectivity and sensitivity over other co-existing molecules, and can be used for quantifying bilirubin with a detection limit down to 257 fM. Additionally, the as-prepared probe was coated on a paper strip to develop a portable paper strip sensor of bilirubin. Moreover, the method was successfully applied in real sample analysis and obtained promising result.
Tao, Yu; Lin, Youhui; Huang, Zhenzhen; Ren, Jinsong; Qu, Xiaogang
2012-01-15
An easy prepared fluorescence turn-on and colorimetric dual channel probe was developed for rapid assay of Hg(2+) ions with high sensitivity and selectivity by using poly(acrylic acid)-templated silver nanoclusters (PAA-AgNCs). The PAA-AgNCs exhibited weak fluorescence, while upon the addition of Hg(2+) ions, AgNCs gives a dramatic increase in fluorescence as a result of the changes of the AgNCs states. The detection limit was estimated to be 2 nM, which is much lower than the Hg(2+) detection requirement for drinking water of U.S. Environmental Protection Agency, and the turn-on sensing mode offers additional advantage to efficiently reduce background noise. Also, a colorimetric assay of Hg(2+) ions can be realized due to the observed absorbance changes of the AgNCs. More importantly, the method was successfully applied to the determination of Hg(2+) ions in real water samples, which suggests our proposed method has a great potential of application in environmental monitoring. Copyright © 2011 Elsevier B.V. All rights reserved.
Improving colorimetric assays through protein enzyme-assisted gold nanoparticle amplification.
Xie, Xiaoji; Xu, Wei; Liu, Xiaogang
2012-09-18
The discovery of the DNA-mediated assembly of gold nanoparticles was a great moment in the history of science; this understanding and chemical control enabled the rational design of functional nanomaterials as novel probes in biodetection. In contrast with conventional probes such as organic dyes, gold nanoparticles exhibit high photostability and unique size-dependent optical properties. Because of their high extinction coefficients and strong distance dependent optical properties, these nanoparticles have emerged over the past decade as a promising platform for rapid, highly sensitive colorimetric assays that allow for the visual detection of low concentrations of metal ions, small molecules, and biomacromolecules. These discoveries have deepened our knowledge of biological phenomena and facilitated the development of many new diagnostic and therapeutic tools. Despite these many advances and continued research efforts, current nanoparticle-based colorimetric detection systems still suffer from several drawbacks, such as limited sensitivity and selectivity. This Account describes the recent development of colorimetric assays based on protein enzyme-assisted gold nanoparticle amplification. The benefits of such detection systems include significantly improved detection sensitivity and selectivity. First, we discuss the general design of enzyme-modified nanoparticle systems in colorimetric assays. We show that a quantitative understanding of the unique properties of different enzymes is paramount for effective biological assays. We then examine the assays for nucleic acid detection based on different types of enzymes, including endonucleases, ligases, and polymerases. For each of these assays, we identify the underlying principles that contribute to the enhanced detection capability of nanoparticle systems and illustrate them with selected examples. Furthermore, we demonstrate that the combination of gold nanoparticles and specific enzymes can probe enzyme dynamics and function with high specificity, offering substantial advantages in both sensitivity and specificity over conventional detection methods. The screening of nuclease, methyltransferase, protease, and kinase activities can be colorimetrically performed in a straightforward manner. Finally, we discuss examples of colorimetric assays for metal ions and small molecules that constitute important advances toward visual monitoring of enzyme catalytic functions and gene expression. Although these enzyme-assisted assay methods hold great promise for myriad applications in biomedicine and bioimaging, the application of the described techniques in vivo faces formidable challenges. In addition, researchers do not fully understand the interactions of gold nanoparticles with enzyme molecules. This understanding will require the development of new techniques to probe enzyme substrate dynamics at the particle interface with higher spatial resolution and chemical specificity.
NASA Astrophysics Data System (ADS)
Wang, Weiguo; Zou, Yake; Yan, Jinwu; Liu, Jing; Chen, Huixiong; Li, Shan; Zhang, Lei
2018-03-01
In this paper, an ultrasensitive colorimetric biosensor for human chorionic gonadotrophin (hCG) detection was designed from bottom-up method based on the dual catalysis of the horseradish peroxidase (HRP) and Au@Pt nanoparticles (NPs) relative to H2O2-TEM system. HRP and monoclonal mouse anti-hCG antibody (β-submit, mAb1) were co-immobilized onto the Au@Pt NP surface to improve catalytic efficiency and specificity, which formed a dual functionalized Au@Pt-HRP probe with the mean size of 42.8 nm (D50). The colorimetric immunoassay was developed for the hCG detection, and the Au@Pt-HRP probe featured a higher sensitivity in the concentration range of 0.4-12.8 IU L- 1 with a low limit of detection (LOD) of 0.1 IU L- 1 compared with the LODs of 0.8 IU L- 1 for BA-ELISA and of 2.0 IU L- 1 for Au@Pt, which indicated that the Au@Pt-HRP probe possessed higher catalytic efficiency with 2.8-fold increase over Au@Pt and 33.8-fold increase over HRP. Also, the Au@Pt-HRP probe exhibited good precision and reproducibility, high specificity and acceptable accuracy with CV being less than 15%. The dual functionalized Au@Pt-HRP probe as a type of signal amplified method was firstly applied in the colorimetric immunoassay for the hCG detection.
Ramezani, Mohammad; Abnous, Khalil; Taghdisi, Seyed Mohammad
2017-01-01
Detection and quantitation of antibiotic residues in blood serum and foodstuffs are in great demand. We have developed aptasensors for detection of streptomycin using electrochemical and optical methods. In the first method, an electrochemical aptasensor was developed for sensitive and selective detection of streptomycin, based on combination of exonuclease I (Exo I), complementary strand of aptamer (CS), arch shaped structure of aptamer (Apt)-CS conjugate, and gold electrode. The designed electrochemical aptasensor exhibited high selectivity toward streptomycin with a limit of detection (LOD) as low as 11.4 nM. Moreover, the developed electrochemical aptasensor was successfully used to detect streptomycin in milk and serum with LODs of 14.1 and 15.3 nM, respectively. In the second method, fluorescence quenching and colorimetric aptasensors were designed for detection of streptomycin based on aqueous gold nanoparticles (AuNPs) and double-stranded DNA (dsDNA). In the absence of streptomycin, aptamer/FAM-labeled complementary strand dsDNA is stable, resulting in the aggregation of AuNPs by salt bridge and an obvious color change from red to blue and strong emission of fluorescence. The colorimetric and fluorescence quenching aptasensors showed excellent selectivity toward streptomycin with limit of detections as low as 73.1 and 47.6 nM, respectively. The presented aptasensors were successfully used to detect streptomycin in milk and serum. For serum, LODs were determined to be 58.2 and 102.4 nM for fluorescence quenching and colorimetric aptasensors, respectively. For milk, LODs were calculated to be 56.2 and 108.7 nM for fluorescence quenching and colorimetric aptasensors, respectively.
Hong, Wooyoung; Lee, Sooyeon; Cho, Youngnam
2016-12-15
We developed a nanoroughened, biotin-doped polypyrrole immunosensor for the detection of tumor markers through dual-signal (electrochemical and colorimetric) channels, electrochemical and colorimetric, that demonstrates remarkable analytical performance. A rapid, one-step electric field-mediated method was employed to fabricate the immunosensor with nanoscale roughness by simply modulating the applied electrical potential. We demonstrated the successful detection of three tumor markers (CA125, CEA, and PSA) via the double enzymatic signal amplifications in the presence of a target antigen, ultimately leading to desired diagnostic accuracy and reliability. The addition of multiple horseradish peroxidase (HRP)- and antibody-labeled nanoparticles greatly amplified the signal and simplified the measurement of cancer biomarker proteins by sequentially magnifying electrochemical and colorimetric signals in a single platform. The two parallel assays performed using the proposed immunosensor have yielded highly consistent and reproducible results. Additionally, for the analysis of plasma samples in a clinical setting, the values obtained with our immunosensor were validated by correlating the results with those of a standard radioimmunoassay (RIA), which obtained very similar clinically valid responses. Copyright © 2016 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Desai, H.B.; Desai, S.R.; Nadkarni, M.N.
1961-01-01
A procedure has been standardized for the determination of boron in cokes, pitches, and graphites. The method consists of fixing the boron present in the sample as calcium borate, ion-exchange separation of boric acid from the associated cations, and the colorimetric determination of boron using the curcumin-trichloracetic acid method. Sulfur which is usually present in pitches and cokes is expected to be oxidized to sulfate during the fixation of boron and hence its effect on the colorimetry has been studied. Application of the procedure to the determination of 0.50 and 1.00 microgram amounts of boron, has given coefficients of variationmore » of l0.0 and 6.7% respectively. (auth)« less
Evaluation of a colorimetric reagent strip assay for urine specific gravity.
Kirschbaum, B B
1983-06-01
N-Multistix SG provides a convenient colorimetric assay for the determination of the specific gravity (sp. gr.) of freshly voided urine. When compared with results obtained by standard hydrometry, the colorimetric assay sp. gr. was observed to decrease by as much as 0.010 units as urine pH increased from 5 to 7. Moderate levels of proteinuria that did not alter hydrometer readings effectively raised the colorimetric sp. gr. by 0.005-0.010 units. The colorimetric assay was almost completely insensitive to clinically encountered concentrations of glucose and urea but responded appropriately to monovalent salts. The magnitude of these observed discrepancies places serious limitations on the value of the colorimetric sp. gr. measurement.
Pitfalls in the detection of cholesterol in Huntington’s disease models
Marullo, Manuela; Valenza, Marta; Leoni, Valerio; Caccia, Claudio; Scarlatti, Chiara; De Mario, Agnese; Zuccato, Chiara; Di Donato, Stefano; Carafoli, Ernesto; Cattaneo, Elena
2012-01-01
Background Abnormalities in brain cholesterol homeostasis have been reported in Huntington’s disease (HD), an adult-onset neurodegenerative disorder caused by an expansion in the number of CAG repeats in the huntingtin (HTT) gene. However, the results have been contradictory with respect to whether cholesterol levels increase or decrease in HD models. Biochemical and mass spectrometry methods show reduced levels of cholesterol precursors and cholesterol in HD cells and in the brains of several HD animal models. Abnormal brain cholesterol homeostasis was also inferred from studies in HD patients. In contrast, colorimetric and enzymatic methods indicate cholesterol accumulation in HD cells and tissues. Here we used several methods to investigate cholesterol levels in cultured cells in the presence or absence of mutant HTT protein. Results Colorimetric and enzymatic methods with low sensitivity gave variable results, whereas results from a sensitive analytical method, gas chromatography-mass spectrometry, were more reliable. Sample preparation, high cell density and cell clonality also influenced the detection of intracellular cholesterol. Conclusions Detection of cholesterol in HD samples by colorimetric and enzymatic assays should be supplemented by detection using more sensitive analytical methods. Care must be taken to prepare the sample appropriately. By evaluating lathosterol levels using isotopic dilution mass spectrometry, we confirmed reduced cholesterol biosynthesis in knock-in cells expressing the polyQ mutation in a constitutive or inducible manner. *Correspondence should be addressed to Elena Cattaneo: elena.cattaneo@unimi.it PMID:23145355
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays.
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-19
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.
Mota, Maria Fernanda S; Souza, Marcella F; Bon, Elba P S; Rodrigues, Marcoaurelio A; Freitas, Suely Pereira
2018-05-24
The use of colorimetric methods for protein quantification in microalgae is hindered by their elevated amounts of membrane-embedded intracellular proteins. In this work, the protein content of three species of microalgae was determined by the Lowry method after the cells were dried, ball-milled, and treated with the detergent sodium dodecyl sulfate (SDS). Results demonstrated that the association of milling and SDS treatment resulted in a 3- to 7-fold increase in protein quantification. Milling promoted microalgal disaggregation and cell wall disruption enabling access of the SDS detergent to the microalgal intracellular membrane proteins and their efficient solubilization and quantification. © 2018 Phycological Society of America.
Plasmon-Based Colorimetric Nanosensors for Ultrasensitive Molecular Diagnostics.
Tang, Longhua; Li, Jinghong
2017-07-28
Colorimetric detection of target analytes with high specificity and sensitivity is of fundamental importance to clinical and personalized point-of-care diagnostics. Because of their extraordinary optical properties, plasmonic nanomaterials have been introduced into colorimetric sensing systems, which provide significantly improved sensitivity in various biosensing applications. Here we review the recent progress on these plasmonic nanoparticles-based colorimetric nanosensors for ultrasensitive molecular diagnostics. According to their different colorimetric signal generation mechanisms, these plasmonic nanosensors are classified into two categories: (1) interparticle distance-dependent colorimetric assay based on target-induced forming cross-linking assembly/aggregate of plasmonic nanoparticles; and (2) size/morphology-dependent colorimetric assay by target-controlled growth/etching of the plasmonic nanoparticles. The sensing fundamentals and cutting-edge applications will be provided for each of them, particularly focusing on signal generation and/or amplification mechanisms that realize ultrasensitive molecular detection. Finally, we also discuss the challenge and give our future perspective in this emerging field.
Okochi, Mina; Kuboyama, Masashi; Tanaka, Masayoshi; Honda, Hiroyuki
2015-09-01
Label-free colorimetric assays using metallic nanoparticles have received much recent attention, for their application in simple and sensitive methods for detection of biomolecules. Short peptide probes that can bind to analyte biomolecules are attractive ligands in molecular nanotechnology; however, identification of biological recognition motifs is usually based on trial-and-error experiments. Herein, a peptide probe was screened for colorimetric detection of angiotensin II (Ang II) using a mechanism for non-crosslinking aggregation of silver nanoparticles (AgNPs). The dual-function peptides, which bind to the analyte and induce AgNP aggregation, were identified using a two-step strategy: (1) screening of an Ang II-binding peptide from an Ang II receptor sequence library, using SPOT technology, which enable peptides synthesis on cellulose membranes via an Fmoc method and (2) selection of peptide probes that effectively induce aggregation of AgNPs using a photolinker modified peptide array. Using the identified peptide probe, KGKNKRRR, aggregation of AgNPs was detected by observation of a pink color in the absence of Ang II, whereas AgNPs remained dispersed in the presence of Ang II (yellow). The color changes were not observed in the presence of other hormone molecules. Ang II could be detected within 15 min, with a detection limit of 10 µM, by measuring the ratio of absorbance at 400 nm and 568 nm; the signal could also be observed with the naked eye. These data suggest that the peptide identified here could be used as a probe for simple and rapid colorimetric detection of Ang II. This strategy for the identification of functional peptides shows promise for the development of colorimetric detection of various diagnostically important biomolecules. Copyright © 2015 Elsevier B.V. All rights reserved.
Seo, Han-bok; Lee, Seung-Yop
2017-01-01
Structure-dependent colour is caused by the interaction of light with photonic crystal structures rather than pigments. The elytra of longhorn beetles Tmesisternus isabellae appear to be iridescent green in a dry state and turn to red when exposed to humidity. Based on the hygroscopic colouration of the longhorn beetle, we have developed centimeter-scale colorimetric opal films using a novel self-assembly method. The micro-channel assisted assembly technique adopts both natural evaporation and rotational forced drying, enhancing the surface binding of silica particles and the packing density by reducing the lattice constant and structural defects. The fabricated large-scale photonic film changes its structural colour from green to red when exposed to water vapour, similarly to the colorimetric feature of the longhorn beetle. The humidity-dependent colour change of the opal film is shown to be reversible and durable over five-hundred cycles of wetting and drying. PMID:28322307
NASA Astrophysics Data System (ADS)
Seo, Han-Bok; Lee, Seung-Yop
2017-03-01
Structure-dependent colour is caused by the interaction of light with photonic crystal structures rather than pigments. The elytra of longhorn beetles Tmesisternus isabellae appear to be iridescent green in a dry state and turn to red when exposed to humidity. Based on the hygroscopic colouration of the longhorn beetle, we have developed centimeter-scale colorimetric opal films using a novel self-assembly method. The micro-channel assisted assembly technique adopts both natural evaporation and rotational forced drying, enhancing the surface binding of silica particles and the packing density by reducing the lattice constant and structural defects. The fabricated large-scale photonic film changes its structural colour from green to red when exposed to water vapour, similarly to the colorimetric feature of the longhorn beetle. The humidity-dependent colour change of the opal film is shown to be reversible and durable over five-hundred cycles of wetting and drying.
GAMMA AND X-RAY DOSIMETER AND DOSIMETRIC METHOD
Taplin, G.V.; Douglas, C.H.; Sigoloff, S.C.
1958-08-19
An improvement in colorimetric gamma and x-ray dosimeter systems and a self-contained. hand carried dostmeter of the afore-mentioned type ts described. A novel point of the invention ltes in the addition of specific quantities of certain normalizing agents to the two phase chlorinated hydro-carbon-aqueous dyc colortmetric dosimeter to eliminate the after reaction and thereby extend the utility of such systein. The structure of the two phase colorimetric dosimeter tubes and the carrying case for the tubes of the portable dosimeter are unique features.
NASA Astrophysics Data System (ADS)
Qi, Yingying; Li, Li; Li, Baoxin
2009-09-01
A simple and sensitive label-free colorimetric detection of telomere DNA has been developed. It was based on the color change of gold nanoparticles (AuNPs) due to DNA hybridization. UV-vis spectra and transmission electron microscopy (TEM) were used to investigate the change of AuNPs. Under the optimized conditions, the linear range for determination of telomere DNA was 5.7 × 10 -13 to 4.5 × 10 -6 mol/L. The detection limit (3 σ) of this method has decreased to pico-molar level.
NASA Astrophysics Data System (ADS)
Powless, Amy J.; Conley, Roxanna J.; Freeman, Karan A.; Muldoon, Timothy J.
2017-03-01
There exists a broad range of techniques that can be used to classify and count white blood cells in a point-of-care (POC) three-part leukocyte differential test. Improvements in lenses, light sources, and cameras for image-based POC systems have renewed interest in acridine orange (AO) as a contrast agent, whereby subpopulations of leukocytes can be differentiated by colorimetric analysis of AO fluorescence emission. We evaluated the effect on test accuracy using different AO staining and postprocessing methods in the context of an image-based POC colorimetric cell classification scheme. Thirty blood specimens were measured for percent cell counts using our POC system and a conventional hematology analyzer for comparison. Controlling the AO concentration used during whole-blood staining, the incubation time with AO, and the colorimetric ratios among the three population of leukocytes yielded a percent deviation of 0.706%, -1.534%, and -0.645% for the lymphocytes, monocytes, and granulocytes, respectively. Overall, we demonstrated that a redshift in AO fluorescence was observed at elevated AO concentrations, which lead to reproducible inaccuracy of cell counts. This study demonstrates there is a need for a strict control of the AO staining and postprocessing methods to improve test accuracy in these POC systems.
Colorimetric determination of sildenafil citrate (Viagra) through ion-associate complex formation.
Amin, Alaa S; Moustafa, Moustafa E; El-Dosoky, Reham
2009-01-01
A simple, quick, accurate, and sensitive colorimetric method is described for the determination of sildenafil citrate (SLD). The method is based on the reaction of SLD with Congo Red, Sudan II, and Gentian Violet in buffered aqueous solutions at pH 2.5, 6.5, and 11.0, respectively, to give highly colored soluble ion-associate complex species; the colored products are quantitated colorimetrically at 523, 554, and 569 nm, respectively. The various experimental conditions were optimized. The stoichiometric ratio was found to be 1:1 for all ion associates; the calculated logarithmic stability constants were 8.51, 7.79, and 5.58, respectively. Beer's law was obeyed over the concentration range of 0.2-7.0 microg/mL, whereas the Ringbom optimum concentration range was 0.4-6.5 microg/mL. Values for molar absorptivity, Sandell sensitivity, and detection and quantification limits were also calculated. The proposed method was successfully applied to the determination of SLD in Viagra tablets and in serum samples by using the technique of standard additions with mean accuracy values of 100.06 +/- 1.14, 99.87 +/- 0.70, and 99.86 +/- 0.97% for Viagra tablets and 99.88 +/- 0.60, 99.90 +/- 0.90, and 100.24 +/- 0.80% for serum samples, respectively.
Makris, Konstantinos C; Punamiya, Pravin; Sarkar, Dibyendu; Datta, Rupali
2008-02-01
A sensitive (method detection limit, 2.0 microg As L(-1)) colorimetric determination of trace As(v) and As(iii) concentrations in the presence of soluble phosphorus (P) concentrations in soil/water extracts is presented. The proposed method modifies the malachite green method (MG) originally developed for P in soil and water. Our method relies upon the finding that As(iii) and As(v) do not develop the green color during P analysis using the MG method. When an optimum concentration of ascorbic acid (AA) is added to a sample containing up to 15 times P > As (microM) concentrations, the final sample absorbance due to P will be equal to that of As(v) molecules. The soluble As concentration can then be quantified by the concentration difference between the mixed oxyanion (As + P) absorbance (proposed method) and the MG method absorbance that measures only P. Our method is miniaturized using a 96-well microplate UV-VIS reader that utilizes minute reagent and sample volumes (120 and 200 microL sample(-1), respectively), thus, minimizing waste and offering flexibility in the field. Our method was tested in a suite of As-contaminated soils that successfully measured both As and P in soil water extracts and total digests. Mean% As recoveries ranged between 84 and 117%, corroborating data obtained with high-resolution inductively-coupled plasma mass-spectrometry. The performance of the proposed colorimetric As method was unaffected by the presence of Cu, Zn, Pb, Ni, Fe, Al, Si, and Cr in both neutral and highly-acidic (ca. pH 2) soil extracts. Data from this study provide the proof of concept towards creating a field-deployable, portable As kit.
A novel kit for rapid detection of Vibrio cholerae O1.
Hasan, J A; Huq, A; Tamplin, M L; Siebeling, R J; Colwell, R R
1994-01-01
We report on the development and testing of a novel, rapid, colorimetric immunodiagnostic kit, Cholera SMART, for direct detection of the presence of Vibrio cholerae O1 in clinical specimens. Unlike conventional culture methods requiring several days to complete, the Cholera SMART kit can be used directly in the field by untrained or minimally skilled personnel to detect V. cholerae O1 in less than 15 min, without cumbersome laboratory equipment. A total of 120 clinical and environmental bacterial strains, including both O1 and non-O1 serotypes of V. cholerae isolated from samples collected from a variety of geographical regions, were tested, and positive reactions were observed only with V. cholerae O1. Also, results of a field trial in Bangladesh, employing Cholera SMART, showed 100% specificity and 96% sensitivity compared with conventional culture methods. Another field trial, in Mexico, showed that Cholera SMART was 100% in agreement with a recently described coagglutination test when 108 stool specimens were tested.
Evaluating an alternative method for rapid urinary creatinine determination
Creatinine (CR) is an endogenously-produced chemical routinely assayed in urine specimens to assess kidney function, sample dilution. The industry-standard method for CR determination, known as the kinetic Jaffe (KJ) method, relies on an exponential rate of a colorimetric change,...
Biochip Which Examines Hepatic Function by Employing Colorimetric Method
NASA Astrophysics Data System (ADS)
Oki, Akio; Ogawa, Hiroki; Takamura, Yuzuru; Horiike, Yasuhiro
2003-03-01
A biochip that is able to quickly analyze hepatic function from the bedside or at home was investigated. The chip essentially consisted of two chips, one that mixed the substrate buffer solution with serums using a centrifugal method and a chip that measured the amounts of γ-glutamyltranspeptidase (γ-GTP), glutamic oxaloacetic transaminase (GOT) and glutamic pyruvic transaminase (GPT) in the serums employing a colorimetric method. The chip should be inexpensive and disposable. Therefore the mixing and measurement channels were fabricated by molding their reverse patterns onto a poly (ethylene terephthalate) (PET) plate. Furthermore, a hydrophobic treatment was performed on the inner wall of the measurement channel to efficiently propagate the light efficiently in the channel. Subsequently, calibration curves were obtained for γ-GTP, GOT and GPT activity levels based on an endpoint method for the γ-GTP and a rate assay for GOT and GPT.
Colorimetric sensor for cysteine in human urine based on novel gold nanoparticles.
Zhang, Yan; Jiang, Jingjing; Li, Min; Gao, Pengfei; Zhou, Ying; Zhang, Guomei; Shuang, Shaomin; Dong, Chuan
2016-12-01
Herein, a novel, high sensitive, and specific colorimetric sensor for cysteine (Cys) based on pectinase protected gold nanoparticles (P@AuNPs) has been demonstrated for the first time. The P@AuNPs were synthesized by "MW-assisted heat method" and were characterized by UV-vis, TEM, FT-IR and zeta potential techniques. Cys could cause the aggregation of P@AuNPs due to formation of the strong covalent Au-S bond and electrostatic binding. As the Cys concentration increased, the color of the solutions gradually changed from wine-red to blue as well as the large absorption band shifted from 523 to 650nm upon P@AuNPs aggregation. In addition, various experimental parameters such as pH, the amount of P@AuNPs and incubation time were investigated for the optimum sensing conditions. The concentration of Cys could be determined by monitoring with the naked eye or a UV-vis spectrometer. The proposed colorimetric sensor showed an extreme selectivity toward the determination of Cys in the presence of 20-fold all other different interferents. Under optimum conditions, this method exhibited two good linear ranges from 4.85×10 -9 to 3.02×10 -4 M (R 2 =0.996) and 3.25×10 -3 to 1.03×10 -2 M (R 2 =0.999), with a low detection limit of 4.6×10 -9 M. Moreover, this colorimetric sensor was successfully applied to the detection of Cys in human urine samples, demonstrating its great value for practical application in biological systems. Copyright © 2016 Elsevier B.V. All rights reserved.
Vardakou, Maria; Salmon, Melissa; Faraldos, Juan A.; O’Maille, Paul E.
2014-01-01
Terpenes are the largest group of natural products with important and diverse biological roles, while of tremendous economic value as fragrances, flavours and pharmaceutical agents. Class-I terpene synthases (TPSs), the dominant type of TPS enzymes, catalyze the conversion of prenyl diphosphates to often structurally diverse bioactive terpene hydrocarbons, and inorganic pyrophosphate (PPi). To measure their kinetic properties, current bio-analytical methods typically rely on the direct detection of hydrocarbon products by radioactivity measurements or gas chromatography–mass spectrometry (GC–MS). In this study we employed an established, rapid colorimetric assay, the pyrophosphate/malachite green assay (MG), as an alternative means for the biochemical characterization of class I TPSs activity.•We describe the adaptation of the MG assay for turnover and catalytic efficiency measurements of TPSs.•We validate the method by direct comparison with established assays. The agreement of kcat/KM among methods makes this adaptation optimal for rapid evaluation of TPSs.•We demonstrate the application of the MG assay for the high-throughput screening of TPS gene libraries. PMID:26150952
Vardakou, Maria; Salmon, Melissa; Faraldos, Juan A; O'Maille, Paul E
2014-01-01
Terpenes are the largest group of natural products with important and diverse biological roles, while of tremendous economic value as fragrances, flavours and pharmaceutical agents. Class-I terpene synthases (TPSs), the dominant type of TPS enzymes, catalyze the conversion of prenyl diphosphates to often structurally diverse bioactive terpene hydrocarbons, and inorganic pyrophosphate (PPi). To measure their kinetic properties, current bio-analytical methods typically rely on the direct detection of hydrocarbon products by radioactivity measurements or gas chromatography-mass spectrometry (GC-MS). In this study we employed an established, rapid colorimetric assay, the pyrophosphate/malachite green assay (MG), as an alternative means for the biochemical characterization of class I TPSs activity.•We describe the adaptation of the MG assay for turnover and catalytic efficiency measurements of TPSs.•We validate the method by direct comparison with established assays. The agreement of k cat/K M among methods makes this adaptation optimal for rapid evaluation of TPSs.•We demonstrate the application of the MG assay for the high-throughput screening of TPS gene libraries.
Majdinasab, Marjan; Hosseini, Seyed Mohammad Hashem; Sepidname, Marziyeh; Negahdarifar, Manizheh; Li, Peiwu
2018-05-01
Alginate is a non-toxic, renewable, and linear copolymer obtained from the brown algae Laminaria digitata that can be easily shaped into beads. Its good gel forming properties have made it useful for entrapping food and pharmaceutical ingredients. In this study, alginate beads were used in a novel application as a colorimetric sensor in food intelligent packaging. Colorimetric sensor was developed through entrapping red cabbage extract as a pH indicator in alginate beads. The pH indicator beads were used in rainbow trout packaging for monitoring fillets spoilage. Color change of beads during fish storage was measured using the CIELab method. The alginate bead colorimetric sensor is validated by measuring total volatile basic nitrogen (TVB-N) levels and microbial populations in fish samples. Moreover, peroxide value (PV) and thiobarbituric acid reactive substances (TBARS) were evaluated during storage. Results indicated that increasing the bacterial population during storage and production of proteolytic enzymes resulted in protein degradation, accumulation of volatile amine compounds, increase in the pH and finally color change of alginate beads. The values of TVB-N, pH, PV and TBARS increased with time of storage. The results of TVB-N and microbial growth were in accordance with color change of beads and CIELab data. Therefore, the proposed system enjoys a high sensitivity to pH variations and is capable of monitoring the spoilage of fish or other protein-rich products through its wide range of color changes. The alginate beads containing the red cabbage extract can, thus, be used as a low-cost colorimetric sensor for intelligent packaging applications.
NASA Astrophysics Data System (ADS)
Mølgaard, Lasse L.; Buus, Ole T.; Larsen, Jan; Babamoradi, Hamid; Thygesen, Ida L.; Laustsen, Milan; Munk, Jens Kristian; Dossi, Eleftheria; O'Keeffe, Caroline; Lässig, Lina; Tatlow, Sol; Sandström, Lars; Jakobsen, Mogens H.
2017-05-01
We present a data-driven machine learning approach to detect drug- and explosives-precursors using colorimetric sensor technology for air-sampling. The sensing technology has been developed in the context of the CRIM-TRACK project. At present a fully- integrated portable prototype for air sampling with disposable sensing chips and automated data acquisition has been developed. The prototype allows for fast, user-friendly sampling, which has made it possible to produce large datasets of colorimetric data for different target analytes in laboratory and simulated real-world application scenarios. To make use of the highly multi-variate data produced from the colorimetric chip a number of machine learning techniques are employed to provide reliable classification of target analytes from confounders found in the air streams. We demonstrate that a data-driven machine learning method using dimensionality reduction in combination with a probabilistic classifier makes it possible to produce informative features and a high detection rate of analytes. Furthermore, the probabilistic machine learning approach provides a means of automatically identifying unreliable measurements that could produce false predictions. The robustness of the colorimetric sensor has been evaluated in a series of experiments focusing on the amphetamine pre-cursor phenylacetone as well as the improvised explosives pre-cursor hydrogen peroxide. The analysis demonstrates that the system is able to detect analytes in clean air and mixed with substances that occur naturally in real-world sampling scenarios. The technology under development in CRIM-TRACK has the potential as an effective tool to control trafficking of illegal drugs, explosive detection, or in other law enforcement applications.
NASA Astrophysics Data System (ADS)
Lee, Ai Cheng; Ye, Jian-Shan; Ngin Tan, Swee; Poenar, Daniel P.; Sheu, Fwu-Shan; Kiat Heng, Chew; Meng Lim, Tit
2007-11-01
A novel carbon nanotube (CNT) derived label capable of dramatic signal amplification of nucleic acid detection and direct visual detection of target hybridization has been developed. Highly sensitive colorimetric detection of human acute lymphocytic leukemia (ALL) related oncogene sequences amplified by the novel CNT-based label was demonstrated. Atomic force microscope (AFM) images confirmed that a monolayer of horseradish peroxidase and detection probe molecules was immobilized along the carboxylated CNT carrier. The resulting CNT labels significantly enhanced the nucleic acid assay sensitivity by at least 1000 times compared to that of conventional labels used in enzyme-linked oligosorbent assay (ELOSA). An excellent detection limit of 1 × 10-12 M (60 × 10-18 mol in 60 µl) and a four-order wide dynamic range of target concentration were achieved. Hybridizations using these labels were coupled to a concentration-dependent formation of visible dark aggregates. Targets can thus be detected simply with visual inspection, eliminating the need for expensive and sophisticated detection systems. The approach holds promise for ultrasensitive and low cost visual inspection and colorimetric nucleic acid detection in point-of-care and early disease diagnostic application.
Discrimination of complex mixtures by a colorimetric sensor array: coffee aromas.
Suslick, Benjamin A; Feng, Liang; Suslick, Kenneth S
2010-03-01
The analysis of complex mixtures presents a difficult challenge even for modern analytical techniques, and the ability to discriminate among closely similar such mixtures often remains problematic. Coffee provides a readily available archetype of such highly multicomponent systems. The use of a low-cost, sensitive colorimetric sensor array for the detection and identification of coffee aromas is reported. The color changes of the sensor array were used as a digital representation of the array response and analyzed with standard statistical methods, including principal component analysis (PCA) and hierarchical clustering analysis (HCA). PCA revealed that the sensor array has exceptionally high dimensionality with 18 dimensions required to define 90% of the total variance. In quintuplicate runs of 10 commercial coffees and controls, no confusions or errors in classification by HCA were observed in 55 trials. In addition, the effects of temperature and time in the roasting of green coffee beans were readily observed and distinguishable with a resolution better than 10 degrees C and 5 min, respectively. Colorimetric sensor arrays demonstrate excellent potential for complex systems analysis in real-world applications and provide a novel method for discrimination among closely similar complex mixtures.
Discrimination of Complex Mixtures by a Colorimetric Sensor Array: Coffee Aromas
Suslick, Benjamin A.; Feng, Liang; Suslick, Kenneth S.
2010-01-01
The analysis of complex mixtures presents a difficult challenge even for modern analytical techniques, and the ability to discriminate among closely similar such mixtures often remains problematic. Coffee provides a readily available archetype of such highly multicomponent systems. The use of a low-cost, sensitive colorimetric sensor array for the detection and identification of coffee aromas is reported. The color changes of the sensor array were used as a digital representation of the array response and analyzed with standard statistical methods, including principal component analysis (PCA) and hierarchical clustering analysis (HCA). PCA revealed that the sensor array has exceptionally high dimensionality with 18 dimensions required to define 90% of the total variance. In quintuplicate runs of 10 commercial coffees and controls, no confusions or errors in classification by HCA were observed in 55 trials. In addition, the effects of temperature and time in the roasting of green coffee beans were readily observed and distinguishable with a resolution better than 10 °C and 5 min, respectively. Colorimetric sensor arrays demonstrate excellent potential for complex systems analysis in real-world applications and provide a novel method for discrimination among closely similar complex mixtures. PMID:20143838
Quantification of Hepcidin-related Iron Accumulation in the Rat Liver.
Böser, Preethne; Mordashova, Yulia; Maasland, Mark; Trommer, Isabel; Lorenz, Helga; Hafner, Mathias; Seemann, Dietmar; Mueller, Bernhard K; Popp, Andreas
2016-02-01
Hepcidin was originally detected as a liver peptide with antimicrobial activity and it functions as a central regulator in the systemic iron metabolism. Consequently suppression of hepcidin leads to iron accumulation in the liver. AbbVie developed a monoclonal antibody ([mAb]; repulsive guidance molecule [RGMa/c] mAb) that downregulates hepcidin expression by influencing the RGMc/bone morphogenetic protein (BMP)/neogenin receptor complex and causes iron deposition in the liver. In a dose range finding study with RGMa/c mAb, rats were treated with different dose levels for a total of 4 weekly doses. The results of this morphometric analysis in the liver showed that iron accumulation is not homogenous between liver lobes and the left lateral lobe was the most responsive lobe in the rat. Quantitative hepcidin messenger RNA analysis showed that the left lateral lobe was the most responsive lobe showing hepcidin downregulation with increasing antibody dose. In addition, the morphometric analysis had higher sensitivity than the chemical iron extraction and quantification using a colorimetric assay. In conclusion, the Prussian blue stain in combination with semi-quantitative and quantitative morphometric analysis is the most reliable method to demonstrate iron accumulation in the liver compared to direct measurement of iron in unfixed tissue using a colorimetric assay. © The Author(s) 2016.
Wang, Shuqin; Deng, Wenfang; Yang, Lu; Tan, Yueming; Xie, Qingji; Yao, Shouzhuo
2017-07-26
Cu-MOF nanoparticles with an average diameter of 550 nm were synthesized from 2-aminoterephthalic acid and Cu(NO 3 ) 2 by a mixed solvothermal method. The Cu-MOF nanoparticles can show peroxidase-like activity that can catalyze 3,3',5,5'-tetramethylbenzidine to produce a yellow chromogenic reaction in the presence of H 2 O 2 . The presence of abundant amine groups on the surfaces of Cu-MOF nanoparticles enables facile modification of Staphylococcus aureus (S. aureus) aptamer on Cu-MOF nanoparticles. By combining Cu-MOF-catalyzed chromogenic reaction with aptamer recognition and magnetic separation, a simple, sensitive, and selective colorimetric method for the detection of S. aureus was developed.
Facial skin color measurement based on camera colorimetric characterization
NASA Astrophysics Data System (ADS)
Yang, Boquan; Zhou, Changhe; Wang, Shaoqing; Fan, Xin; Li, Chao
2016-10-01
The objective measurement of facial skin color and its variance is of great significance as much information can be obtained from it. In this paper, we developed a new skin color measurement procedure which includes following parts: first, a new skin tone color checker made of pantone Skin Tone Color Checker was designed for camera colorimetric characterization; second, the chromaticity of light source was estimated via a new scene illumination estimation method considering several previous algorithms; third, chromatic adaption was used to convert the input facial image into output facial image which appears taken under canonical light; finally the validity and accuracy of our method was verified by comparing the results obtained by our procedure with these by spectrophotometer.
Colorimetric sensing of anions in water using ratiometric indicator-displacement assay.
Feng, Liang; Li, Hui; Li, Xiao; Chen, Liang; Shen, Zheng; Guan, Yafeng
2012-09-19
The analysis of anions in water presents a difficult challenge due to their low charge-to-radius ratio, and the ability to discriminate among similar anions often remains problematic. The use of a 3×6 ratiometric indicator-displacement assay (RIDA) array for the colorimetric detection and identification of ten anions in water is reported. The sensor array consists of different combinations of colorimetric indicators and metal cations. The colorimetric indicators chelate with metal cations, forming the color changes. Upon the addition of anions, anions compete with the indicator ligands according to solubility product constants (K(sp)). The indicator-metal chelate compound changes color back dramatically when the competition of anions wins. The color changes of the RIDA array were used as a digital representation of the array response and analyzed with standard statistical methods, including principal component analysis and hierarchical clustering analysis. No confusion or errors in classification by hierarchical clustering analysis were observed in 44 trials. The limit of detection was calculated approximately, and most limits of detections of anions are well below μM level using our RIDA array. The pH effect, temperature influence, interfering anions were also investigated, and the RIDA array shows the feasibility of real sample testing. Copyright © 2012 Elsevier B.V. All rights reserved.
This method describes procedures for preparation and analysis of solid, water and wipe samples for detection and measurement of cyanide amendable to chlorination using acid digestion and spectrophotometry.
Deng, Jingjing; Shi, Guoyue; Zhou, Tianshu
2016-10-26
This study demonstrates a new strategy for colorimetric detection of alcoholic strength (AS) in spirit samples based on dual-responsive lanthanide infinite coordination polymer (Ln-ICP) particles with ratiometric fluorescence. The ICP used in this study are composed of two components: one is the supramolecular Ln-ICP network formed by the coordination between the ligand 2,2'-thiodiacetic acid (TDA) and central metal ion Eu 3+ ; and the other is a fluorescent dye, i.e., coumarin 343 (C343), both as the cofactor ligand and as the sensitizer, doped into the Ln-ICP network through self-adaptive chemistry. Upon being excited at 300 nm, the red fluorescence of Ln-ICP network itself at 617 nm is highly enhanced due to the concomitant energy transfer from C343 to Eu 3+ , while the fluorescence of C343 at 495 nm is supressed. In pure ethanol solvent, the as-formed C343@Eu-TDA is well dispersed and quite stable. However, the addition of water into ethanolic dispersion of C343@Eu-TDA destructs Eu-TDA network structure, resulting in the release of C343 from ICP network into the solvent. Consequently, the fluorescence of Eu-TDA turns off and the fluorescence of C343 turns on, leading to the fluorescent color change of the dispersion from red to blue, which constitutes a new mechanism for colorimetric sensing of AS in commercial spirit samples. With the method developed here, we could clearly distinguish the AS of different spirit samples within a wide linear range from 10% vol to 100% vol directly by "naked eye" with the help of UV-lamp (365 nm). This study not only offers a new method for on-the-spot visible detection of AS, but also provides a strategy for dual-responsive sensing mode by rational designing the optical properties of the Ln-ICP network and the guest, respectively. Copyright © 2016 Elsevier B.V. All rights reserved.
A Colorimetric and Fluorescent Chemosensor of Fe3+ Based on an Asymmetrical Squarylium Dye
NASA Astrophysics Data System (ADS)
Lu, Min; Wang, Yue; Li, Ying; Li, Zhongyu; Xu, Song; Yao, Chao
2018-05-01
A novel asymmetrical squarylium-dye-based dual signaling probe was synthesized and found to exhibit colorimetric and fluorescent properties on selective binding towards Fe3+ in ethanol/water (4:1, v/v) solution. The binding constant was determined to be 7.69 × 102 M-1, and the detection limit of SQ was 9.158 × 10-6 M. Most importantly, the 1:2 stoichiometry of the host-guest complexation was confirmed by Job's method. Moreover, the high sensing ability of the receptor towards Fe3+ was also investigated by the electrochemical technique.
Occurrence of hexavalent chromium in ground water in the western Mojave Desert, California
Ball, J.W.; Izbicki, J.A.
2004-01-01
About 200 samples from selected public supply, domestic, and observation wells completed in alluvial aquifers underlying the western Mojave Desert were analyzed for total dissolved Cr and Cr(VI). Because Cr(VI) is difficult to preserve, samples were analyzed by 3 methods. Chromium(VI) was determined in the field using both a direct colorimetric method and EPA method 218.6, and samples were speciated in the field for later analysis in the laboratory using a cation-exchange method developed for the study described in this paper. Comparison of the direct colorimetric method and EPA method 218.6 with the new cation-exchange method yielded r2 values of 0.9991 and 0.9992, respectively. Total dissolved Cr concentrations ranged from less than the 0.1 ??g/l detection limit to 60 ??g/l, and almost all the Cr present was Cr(VI). Near recharge areas along the mountain front pH values were near neutral, dissolved O2 concentrations were near saturation, and Cr(VI) concentrations were less than the 0.1 ??g/l detection limit. Chromium(VI) concentrations and pH values increased downgradient as long as dissolved O 2 was present. However, low Cr(VI) concentrations were associated with low dissolved O2 concentrations near ground-water discharge areas along dry lakes. Chromium(VI) concentrations as high as 60 ??g/l occurred in ground water from the Sheep Creek fan alluvial deposits weathered from mafic rock derived from the San Gabriel Mountains, and Cr(VI) concentrations as high as about 36 ??g/l were present in ground water from alluvial deposits weathered from less mafic granitic, metamorphic, and volcanic rocks. Chromium(III) was the predominant form of Cr only in areas where dissolved O2 concentrations were less than 1 mg/l and was detected at a median concentration of 0.1 ??g/l, owing to its low solubility in water of near-neutral pH. Depending on local hydrogeologic conditions and the distribution of dissolved O2, Cr(VI) concentrations may vary considerably with depth. Samples collected under pumping conditions from different depths within wells show that Cr(VI) concentrations can range from less than the 0.1 ??g/l detection limit to 36 ??g/l in a single well and that dissolved O2 concentrations likely control the concentration and redox speciation of Cr in ground water.
Real-time monitoring of enzyme-free strand displacement cascades by colorimetric assays
NASA Astrophysics Data System (ADS)
Duan, Ruixue; Wang, Boya; Hong, Fan; Zhang, Tianchi; Jia, Yongmei; Huang, Jiayu; Hakeem, Abdul; Liu, Nannan; Lou, Xiaoding; Xia, Fan
2015-03-01
The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications.The enzyme-free toehold-mediated strand displacement reaction has shown potential for building programmable DNA circuits, biosensors, molecular machines and chemical reaction networks. Here we report a simple colorimetric method using gold nanoparticles as signal generators for the real-time detection of the product of the strand displacement cascade. During the process the assembled gold nanoparticles can be separated, resulting in a color change of the solution. This assay can also be applied in complex mixtures, fetal bovine serum, and to detect single-base mismatches. These results suggest that this method could be of general utility to monitor more complex enzyme-free strand displacement reaction-based programmable systems or for further low-cost diagnostic applications. Electronic supplementary information (ESI) available: Experimental procedures and analytical data are provided. See DOI: 10.1039/c5nr00697j
[Colorimetric characterization of LCD based on wavelength partition spectral model].
Liu, Hao-Xue; Cui, Gui-Hua; Huang, Min; Wu, Bing; Xu, Yan-Fang; Luo, Ming
2013-10-01
To establish a colorimetrical characterization model of LCDs, an experiment with EIZO CG19, IBM 19, DELL 19 and HP 19 LCDs was designed and carried out to test the interaction between RGB channels, and then to test the spectral additive property of LCDs. The RGB digital values of single channel and two channels were given and the corresponding tristimulus values were measured, then a chart was plotted and calculations were made to test the independency of RGB channels. The results showed that the interaction between channels was reasonably weak and spectral additivity property was held well. We also found that the relations between radiations and digital values at different wavelengths varied, that is, they were the functions of wavelength. A new calculation method based on piecewise spectral model, in which the relation between radiations and digital values was fitted by a cubic polynomial in each piece of wavelength with measured spectral radiation curves, was proposed and tested. The spectral radiation curves of RGB primaries with any digital values can be found out with only a few measurements and fitted cubic polynomial in this way and then any displayed color can be turned out by the spectral additivity property of primaries at given digital values. The algorithm of this method was discussed in detail in this paper. The computations showed that the proposed method was simple and the number of measurements needed was reduced greatly while keeping a very high computation precision. This method can be used as a colorimetrical characterization model.
Li, Z; Chang, S; Lin, L; Li, Y; An, Q
2011-08-01
1-Aminocyclopropane-1-carboxylate (ACC) deaminase activity is an efficient marker for bacteria to promote plant growth by lowering ethylene levels in plants. We aim to develop a method for rapidly screening bacteria containing ACC deaminase, based on a colorimetric ninhydrin assay of ACC. A reliable colorimetric ninhydrin assay was developed to quantify ACC using heat-resistant polypropylene chimney-top 96-well PCR plates, having the wells evenly heated in boiling water, preventing accidental contamination from boiling water and limiting evaporation. With this method to measure bacterial consumption of ACC, 44 ACC-utilizing bacterial isolates were rapidly screened out from 311 bacterial isolates that were able to grow on minimal media containing ACC as the sole nitrogen source. The 44 ACC-utilizing bacterial isolates showed ACC deaminase activities and belonged to the genus Burkholderia, Pseudomonas or Herbaspirillum. Determination of bacterial ACC consumption by the PCR-plate ninhydrin-ACC assay is a rapid and efficient method for screening bacteria containing ACC deaminase from a large number of bacterial isolates. The PCR-plate ninhydrin-ACC assay extends the utility of the ninhydrin reaction and enables a rapid screening of bacteria containing ACC deaminase from large numbers of bacterial isolates. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.
Senarathna, S.M.D.K. Ganga; Ranganathan, Shalini S.; Buckley, Nick; Soysa, S.S.S.B.D. Preethi; Fernandopulle, B. M. Rohini
2012-01-01
Objectives: Acute paracetamol poisoning is an emerging problem in Sri Lanka. Management guidelines recommend ingested dose and serum paracetamol concentrations to assess the risk. Our aim was to determine the usefulness of the patient's history of an ingested dose of >150 mg/kg and paracetamol concentration obtained by a simple colorimetric method to assess risk in patients with acute paracetamol poisoning. Materials and Methods: Serum paracetamol concentrations were determined in 100 patients with a history of paracetamol overdose using High Performance Liquid Chromatography (HPLC); (reference method). The results were compared to those obtained with a colorimetric method. The utility of risk assessment by reported dose ingested and colorimetric analysis were compared. Results: The area under the receiver operating characteristic curve for the history of ingested dose was 0.578 and there was no dose cut-off providing useful risk categorization. Both analytical methods had less than 5% intra- and inter-batch variation and were accurate on spiked samples. The time from blood collection to result was six times faster and ten times cheaper for colorimetry (30 minutes, US$2) than for HPLC (180 minutes, US$20). The correlation coefficient between the paracetamol levels by the two methods was 0.85. The agreement on clinical risk categorization on the standard nomogram was also good (Kappa = 0.62, sensitivity 81%, specificity 89%). Conclusions: History of dose ingested alone greatly over-estimated the number of patients who need antidotes and it was a poor predictor of risk. Paracetamol concentrations by colorimetry are rapid and inexpensive. The use of these would greatly improve the assessment of risk and greatly reduce unnecessary expenditure on antidotes. PMID:23087506
Wang, Qian; Pang, Hongchang; Dong, Yongqiang; Chi, Yuwu; Fu, Fengfu
2018-05-10
A kind of single-layer carbon based dots (CDs) with abundant carboxyl functional groups was hybridized with manganese dioxide (MnO 2 ). The resulting nanohybrid is stable and can be well dispersed in water. MnO 2 is capable of oxidizing the substrate 3,3'5,5'-tetramethylbenzidine (TMB) to form a blue product whose absorption (peaking at 655 nm) fades in the presence of glutathione (GSH). A sensitive and selective colorimetric GSH assay was worked out that has a linear response in the 10 to 0.1 µM GSH concentration range, with a 0.095 μM detection limit. The method was applied to the determination of GSH in spiked fetal calf serum where it gave excellent recoveries. Graphical abstract Schematic of the preparation of a nanohybrid composed of manganese dioxide and carbon based dots (MnO 2 /CDs). They can be used for the colorimetric detection of glutathione (GSH) based on the color change of 3,3'5,5'-tetramethylbenzidine (TMB).
Spectral gamuts and spectral gamut mapping
NASA Astrophysics Data System (ADS)
Rosen, Mitchell R.; Derhak, Maxim W.
2006-01-01
All imaging devices have two gamuts: the stimulus gamut and the response gamut. The response gamut of a print engine is typically described in CIE colorimetry units, a system derived to quantify human color response. More fundamental than colorimetric gamuts are spectral gamuts, based on radiance, reflectance or transmittance units. Spectral gamuts depend on the physics of light or on how materials interact with light and do not involve the human's photoreceptor integration or brain processing. Methods for visualizing a spectral gamut raise challenges as do considerations of how to utilize such a data-set for producing superior color reproductions. Recent work has described a transformation of spectra reduced to 6-dimensions called LabPQR. LabPQR was designed as a hybrid space with three explicit colorimetric axes and three additional spectral reconstruction axes. In this paper spectral gamuts are discussed making use of LabPQR. Also, spectral gamut mapping is considered in light of the colorimetric-spectral duality of the LabPQR space.
Gao, Zhuangqiang; Hou, Li; Xu, Mingdi; Tang, Dianping
2014-01-01
Methods based on enzyme labels have been developed for colorimetric immunoassays, but most involve poor sensitivity and are unsuitable for routine use. Herein, we design an enhanced colorimetric immunoassay for prostate-specific antigen (PSA) coupling with an enzyme-cascade-amplification strategy (ECAS-CIA). In the presence of target PSA, the labeled alkaline phosphatase on secondary antibody catalyzes the formation of palladium nanostructures, which catalyze 3,3′,5,5′-tetramethylbenzidine-H2O2 system to produce the colored products, thus resulting in the signal cascade amplification. Results indicated that the ECAS-CIA presents good responses toward PSA, and allows detection of PSA at a concentration as low as 0.05 ng mL−1. Intra- and inter-assay coefficients of variation are below 9.5% and 10.7%, respectively. Additionally, the methodology is validated for analysis of clinical serum specimens with consistent results obtained by PSA ELISA kit. Importantly, the ECAS-CIA opens a new horizon for protein diagnostics and biosecurity. PMID:24509941
Akar, Zeynep; Küçük, Murat; Doğan, Hacer
2017-12-01
2,2-Diphenyl-1-picrylhydrazyl (DPPH • ) radical scavenging, the most commonly used antioxidant method with more than seventeen thousand articles cited, is very practical; however, as with most assays, it has the major disadvantage of dependence on a spectrophotometer. To overcome this drawback, the colorimetric determination of the antioxidant activity using a scanner and freely available Image J software was developed. In this new method, the mixtures of solutions of DPPH • and standard antioxidants or extracts of common medicinal herbs were dropped onto TLC plates, after an incubation period. The spot images were evaluated with Image J software to determine CSC 50 values, the sample concentrations providing 50% colour reduction, which were very similar with the SC 50 values obtained with spectrophotometric method. The advantages of the new method are the use of lower amounts of reagents and solvents, no need for costly spectrophotometers, and thus significantly lowered costs, and convenient implementation in any environment and situation.
Testolin, Renan C; Almeida, Tito C M; Polette, Marcus; Branco, Joaquim O; Fischer, Larissa L; Niero, Guilherme; Poyer-Radetski, Gabriel; Silva, Valéria C; Somensi, Cleder A; Corrêa, Albertina X R; Corrêa, Rogério; Rörig, Leonardo R; Itokazu, Ana Gabriela; Férard, Jean-François; Cotelle, Sylvie; Radetski, Claudemir M
2017-05-15
There is scientific evidence that beach sands are a significant contributor to the pathogen load to which visitors are exposed. To develop beach quality guidelines all beach zones must be included in microbiological evaluations, but monitoring methods for beach sand quality are relatively longstanding, expensive, laborious and require moderate laboratory infrastructure. This paper aimed to evaluate the microorganism activity in different beach zones applying and comparing a classical method of membrane filtration (MF) with two colorimetric screening methods based on fluorescein (FDA) and tetrazolium (TTC) salt biotransformation to evaluate a new rapid and low-cost method for beach sand microbiological contamination assessments. The colorimetric results can help beach managers to evaluate rapidly and at low cost the microbiological quality of different beach zones in order to decide whether remedial actions need to be adopted to prevent exposure of the public to microbes due to beach sand and/or water contamination. Copyright © 2017. Published by Elsevier Ltd.
Ultrasensitive colorimetric detection of Cu2+ ion based on catalytic oxidation of L-cysteine.
Yin, Kun; Li, Bowei; Wang, Xiaochun; Zhang, Weiwei; Chen, Lingxin
2015-02-15
As an essential element, copper ion (Cu(2+)) plays important roles in human beings for its participation in diverse metabolic processes as a cofactor and/or a structural component of enzymes. However, excessive uptake of Cu(2+) ion gives rise to the risk of certain diseases. So, it is important to develop simple ways to monitor and detect Cu(2+) ion. In this study, a simple, facile colorimetric sensor for the ultrasensitive determination of Cu(2+) ion was developed based on the following principle: L-cysteine and 1-chloro-2,4-dinitrobenzene (CDNB) could be conjugated to form the yellow product 2,4-dinitrophenylcysteine (DNPC), which was measurable at 355nm; however, upon addition of Cu(2+) ion, the absorbance of DNPC would be decreased owing to the Cu(2+) ion catalytic oxidation of L-cysteine to L-cystine in the presence of O2. Thus, the colorimetric detection of Cu(2+) ion could be achieved. The optimal pH, buffer, temperature and incubation time for the colorimetric sensor were obtained of pH 6.8 in 0.1M HEPES solution, 90 °C and 50 min, respectively. A good linearity within the range of 0.8-10 nM (r = 0.996) was attained, with a high detectability up to 0.5nM. Analyses of Cu(2+) ion in drinking water, lake water, seawater and biological samples were carried out and the method performances were found to agree well with that obtained by ICP-MS. The developed simple colorimetric sensor proved applicable for Cu(2+) ion determination in real samples with high sensitivity and selectivity. Copyright © 2014 Elsevier B.V. All rights reserved.
USDA-ARS?s Scientific Manuscript database
A sample preparation method was evaluated for the determination of polybrominated diphenyl ethers (PBDEs) in mussel samples, by using colorimetric and electrochemical immunoassay-based screening methods. A simple sample preparation in conjunction with a rapid screening method possesses the desired c...
A continuous spectrophotometric assay method for peptidylarginine deiminase type 4 activity.
Liao, Ya-Fan; Hsieh, Hui-Chieh; Liu, Guang-Yaw; Hung, Hui-Chih
2005-12-15
A simple, continuous spectrophotometric assay for peptidylarginine deiminase (PAD) is described. Deimination of peptidylarginine results in the formation of peptidylcitrulline and ammonia. The ammonia released during peptidylarginine hydrolysis is coupled to the glutamate-dehydrogenase-catalyzed reductive amination of alpha-ketoglutarate to glutamate and reduced nicotinamide adenine dinucleotide (NADH) oxidation. The disappearance of absorbance at 340nm due to NADH oxidation is continuously measured. The specific activity obtained by this new protocol for highly purified human PAD is comparable to that obtained by a commonly used colorimetric procedure, which measures the ureido group of peptidylcitrulline by coupling with diacetyl monoxime. The present continuous spectrophotometric method is highly sensitive and accurate and is thus suitable for enzyme kinetic analysis of PAD. The Ca(2+) concentration for half-maximal activity of PAD obtained by this method is comparable to that previously obtained by the colorimetric procedure.
The colorimetric analysis of anti-tuberculosis fixed-dose combination tablets and capsules.
Ellard, G A
1999-11-01
The perceived need to demonstrate whether or not the actual amounts of rifampicin, isoniazid and pyrazinamide in fixed-dose combination tablets or capsules correspond to their stated drug contents. To adapt specific, robust and simple colorimetric methods that have been previously applied to measuring plasma and urinary rifampicin, isoniazid, pyrazinamide and ethambutol concentrations to estimate tablet and capsule drug contents. The methods were applied to the analysis of 14 commercially manufactured fixed-dose combinations: two capsule and three tablet formulations containing rifampicin and isoniazid; seven tablet formulations containing rifampicin, isoniazid and pyrazinamide; and two tablet formulations containing rifampicin, isoniazid, pyrazinamide and ethambutol. All the combined formulations contained near to their stated drug contents. Replicate analyses confirmed the excellent precision of the drug analyses. Such methods are not only rapid to perform but should be practical in many Third World situations with relatively modest laboratory facilities.
Reconstruction of reflectance data using an interpolation technique.
Abed, Farhad Moghareh; Amirshahi, Seyed Hossein; Abed, Mohammad Reza Moghareh
2009-03-01
A linear interpolation method is applied for reconstruction of reflectance spectra of Munsell as well as ColorChecker SG color chips from the corresponding colorimetric values under a given set of viewing conditions. Hence, different types of lookup tables (LUTs) have been created to connect the colorimetric and spectrophotometeric data as the source and destination spaces in this approach. To optimize the algorithm, different color spaces and light sources have been used to build different types of LUTs. The effects of applied color datasets as well as employed color spaces are investigated. Results of recovery are evaluated by the mean and the maximum color difference values under other sets of standard light sources. The mean and the maximum values of root mean square (RMS) error between the reconstructed and the actual spectra are also calculated. Since the speed of reflectance reconstruction is a key point in the LUT algorithm, the processing time spent for interpolation of spectral data has also been measured for each model. Finally, the performance of the suggested interpolation technique is compared with that of the common principal component analysis method. According to the results, using the CIEXYZ tristimulus values as a source space shows priority over the CIELAB color space. Besides, the colorimetric position of a desired sample is a key point that indicates the success of the approach. In fact, because of the nature of the interpolation technique, the colorimetric position of the desired samples should be located inside the color gamut of available samples in the dataset. The resultant spectra that have been reconstructed by this technique show considerable improvement in terms of RMS error between the actual and the reconstructed reflectance spectra as well as CIELAB color differences under the other light source in comparison with those obtained from the standard PCA technique.
Wang, Lin; Liu, Zhanmin; Xia, Xueying; Yang, Cuiyun; Huang, Junyi; Wan, Sibao
2017-05-01
Cucumber green mottle mosaic virus (CGMMV)causes a severe mosaic symptom of watermelon and cucumber, and can be transmitted via infected cucumber seeds, leaves and soil. It remains a challenge to detect this virus to prevent its introduction and infection and spread in fields. For this purpose, a simple and sensitive label-free colorimetric detection method for CGMMV has been developed with unmodified gold nanoparticles (AuNPs) as colorimetric probes. The method is based on the finding that the presence of RT-PCR target products of CGMMV and species-specific probes results in color change of AuNPs from red to blue after NaCl induction. Normally, species-specific probes attach to the surface of AuNPs and thereby increasing their resistance to NaCl-induced aggregation. The concentration of sodium, probes in the reaction system and evaluation of specificity and sensitivity of a novel assay, visual detection of Cucumber green mottle mosaic virus using unmodified AuNPs has been carried out with simple preparation of samples in our study. Through this assay, as low as 30pg/μL of CGMMV RNA was thus detected visually, by the naked eye, without the need for any sophisticated, expensive instrumentation and biochemical reagents. The specificity was 100% and exhibited good reproducibility in our assays. The results note that this assay is highly species-specific, simple, low-cost, and visual for easy detection of CGMMV in plant tissues. Therefore, visual assay is a potentially useful tool for middle or small-scales corporations and entry-exit inspection and quarantine bureau to detect CGMMV in cucumber seeds or plant tissues. Copyright © 2017 Elsevier B.V. All rights reserved.
ERIC Educational Resources Information Center
Kleppinger, E. W.; And Others
1984-01-01
Although determination of phosphorus is important in biology, physiology, and environmental science, traditional gravimetric and colorimetric methods are cumbersome and lack the requisite sensitivity. Therefore, a derivative activation analysis method is suggested. Background information, procedures, and results are provided. (JN)
Colorimetric consideration of transparencies for a typical LACIE scene
NASA Technical Reports Server (NTRS)
Juday, R. D. (Principal Investigator)
1979-01-01
The production film converter used to produce LACIE imagery is described as well as schemes designed to provide the analyst with operational film products. Two of these products are discussed from the standpoint of color theory. Colorimetric terminology is defined and the mathematical calculations are given. Topics covered include (1) history of product 1 and 3 algorithm development; (2) colorimetric assumptions for product 1 and 3 algorithms; (3) qualitative results from a colorimetric analysis of a typical LACIE scene; and (4) image-to-image color stability.
NASA Astrophysics Data System (ADS)
Zareh Jonaghani, Mohammad; Zali-Boeini, Hassan
2017-05-01
A highly efficient and selective fluorescent and colorimetric chemosensor based on naphthothiazole skeleton was synthesized and its colorimetric and fluorescent properties were investigated. The sensor displays a rapid and highly selective colorimetric and fluorescence response toward Hg2 + without interference with other metal ions in CH3CN/H2O mixture (50/50, v/v). The detection limit for the fluorescent chemosensor S1 toward Hg2 + was 3.42 × 10- 8 M.
Senarathna, S M D K Ganga; Ranganathan, Shalini S; Buckley, Nick; Soysa, S S S B D Preethi; Fernandopulle, B M Rohini
2012-01-01
Acute paracetamol poisoning is an emerging problem in Sri Lanka. Management guidelines recommend ingested dose and serum paracetamol concentrations to assess the risk. Our aim was to determine the usefulness of the patient's history of an ingested dose of >150 mg/kg and paracetamol concentration obtained by a simple colorimetric method to assess risk in patients with acute paracetamol poisoning. Serum paracetamol concentrations were determined in 100 patients with a history of paracetamol overdose using High Performance Liquid Chromatography (HPLC); (reference method). The results were compared to those obtained with a colorimetric method. The utility of risk assessment by reported dose ingested and colorimetric analysis were compared. The area under the receiver operating characteristic curve for the history of ingested dose was 0.578 and there was no dose cut-off providing useful risk categorization. Both analytical methods had less than 5% intra- and inter-batch variation and were accurate on spiked samples. The time from blood collection to result was six times faster and ten times cheaper for colorimetry (30 minutes, US$2) than for HPLC (180 minutes, US$20). The correlation coefficient between the paracetamol levels by the two methods was 0.85. The agreement on clinical risk categorization on the standard nomogram was also good (Kappa = 0.62, sensitivity 81%, specificity 89%). History of dose ingested alone greatly over-estimated the number of patients who need antidotes and it was a poor predictor of risk. Paracetamol concentrations by colorimetry are rapid and inexpensive. The use of these would greatly improve the assessment of risk and greatly reduce unnecessary expenditure on antidotes.
De Silva, Veronica; Oldham, Charlie D; May, Sheldon W
2010-09-01
Phenylketonuria (PKU) is an autosomal recessive disorder caused by an impaired conversion of L-phenylalanine (Phe) to L-tyrosine, typically resulting from a deficiency in activity of a hepatic and renal enzyme L-phenylalanine hydroxylase. The disease is characterized by an increased concentration of Phe and its metabolites in body fluids. A modified assay based on an enzymatic-colorimetric methodology was developed for measuring blood Phe levels in PKU patients; this method is designed for use with undeproteinized samples and avoids the use of solvents or amphiphilic agents. Thus, the method could be suitable for incorporation into a simple home-monitoring device. We report here on a comparison of blood Phe concentrations in PKU patients measured in undeproteinized plasma using this enzyme colorimetric assay (ECA), with values determined by amino acid analysis (AAA) of deproteinized samples, and HPLC and tandem mass spectrometry (MS/MS) analyses of dried blood spot (DBS) eluates. Pearson correlation coefficients of 0.951, 0.976 and 0.988 were obtained when AAA-measured Phe concentrations were compared with the ECA-, HPLC- or MS/MS-measured values, respectively. A Bland-Altman analysis revealed that mean Phe concentrations determined using AAA were on average 65 μmol/L lower than values measured by our ECA. These results may be the result of minimizing the manipulations performed on the patient sample compared with AAA, HPLC, and MS/MS methods, which involve plasma deproteinization or DBS elution and derivatization. The results reported here confirm that Phe concentrations determined by our ECA method are comparable to those determined by other widely used methods for a broad range of plasma Phe concentrations.
Colorimetric sensing of selenocystine using gold nanoparticles.
Liu, Liyang; Wang, Xia; Yang, Juan; Bai, Yan
2017-10-15
We present a highly selective and sensitive colorimetric method for the detection of selenocystine (SeCys) coexisting with other amino acids, especially cysteine (Cys) using the gold nanoparticles (AuNPs). Firstly, Cys was oxidized to cystine (Cys-Cys) by dissolved oxygen under Cu 2+ catalysis in the pre-reaction, which eliminated the interference of Cys in the SeCys sensing process. Then SeCys induced the rapid aggregation of AuNPs through Au-Se bond and complex formation of Cu 2+ -SeCys in the colorimetric reaction, in which the color change of AuNPs from red to blue or purple with the naked eye detection or with a UV-vis spectrophotometric determination. The concentration of SeCys was quantified by the value at 670 nm from the second-derivative SPR absorbance spectrum. The linear range was from 2 μM to 14 μM with correlation coefficient of 0.999 and a detection limit (LOD) was 0.14 μM. Moreover, the colorimetric response of AuNPs exhibited remarkable specificity to SeCys coexisting with 18 amino acids in a simulation sample, in which the total concentration of Cys and Cys-Cys was less than 15 μM and the each concentration of other 16 common amino acids was 10 μM. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Kang, Fei; Hou, Xiangshu; Xu, Kun
2015-10-01
Glucose is a key energy substance in diverse biology and closely related to the life activities of the organism. To develop a simple and sensitive method for glucose detection is extremely urgent but still remains a key challenge. Herein, we report a colorimetric glucose sensor in a homogeneous system based on DNA-embedded core-shell Au@Ag nanoparticles. In this assay, a glucose substrate was first catalytically oxidized by glucose oxidase to produce H2O2 which would further oxidize and gradually etch the outer silver shell of Au@Ag nanoparticles. Afterwards, the solution color changed from yellow to red and the surface plasmon resonance (SPR) band of Au@Ag nanoparticles declined and red-shifted from 430 to 516 nm. Compared with previous silver-based glucose colorimetric detection strategies, the distinctive SPR band change is superior to the color variation, which is critical to the high sensitivity of this assay. Benefiting from the outstanding optical property, robust stability and well-dispersion of the core-shell Au@AgNPs hybrid, this colorimetric assay obtained a detection limit of glucose as low as 10 nM, which is at least a 10-fold improvement over other AgNPs-based procedures. Moreover, this optical biosensor was successfully employed to the determination of glucose in fetal bovine serum.
The effect of carbonated beverages on colorimetric end-tidal CO(2) determination
Qureshi; Park; Sturmann; Hsu
2000-10-01
Esophageal intubation is a significant complication of attempted airway control. Colorimetric end-tidal CO(2) monitors are highly sensitive and specific for detecting the presence of CO(2). There are reports of false-positive end-tidal CO(2) readings from esophageal intubations in patients who had ingested carbonated beverages. OBJECTIVE: To determine whether carbonated gastric contents can affect colorimetric end-tidal CO(2) readings. METHODS: End-tidal CO(2) was measured in sacrificed piglets at measured time intervals after instillation of 5-, 10-, 15-, and 20-mL aliquots of Diet Coke were placed into the stomach via a 28-French orogastric tube followed by esophageal intubation. The stomach was completely evacuated prior to each instillation and rechecked for baseline CO(2). RESULTS: Compiled data from three piglets (20-30 kg). Piglets were not ventilated or moved and determinations were measured at 20 degrees while supine. All data collected within 2 hours postmortem (table 24-1). CONCLUSIONS: The colorimetric end-tidal CO(2) turned "yellow" and did not change to blue with extended insufflations. The CO(2) of a small quantity of carbonated beverage in the stomach could be "blown off" by multiple insufflations. We conclude that esophageal intubation in the setting of recent ingestion of a carbonated beverage may result in a false-positive end-tidal CO(2) determination.
Hu, Bo; Guo, Jing; Xu, Ying; Wei, Hua; Zhao, Guojie; Guan, Yifu
2017-08-01
Rapid and accurate detection of microRNAs in biological systems is of great importance. Here, we report the development of a visual colorimetric assay which possesses the high amplification capabilities and high selectivity of the rolling circle amplification (RCA) method and the simplicity and convenience of gold nanoparticles used as a signal indicator. The designed padlock probe recognizes the target miRNA and is circularized, and then acts as the template to extend the target miRNA into a long single-stranded nucleotide chain of many tandem repeats of nucleotide sequences. Next, the RCA product is hybridized with oligonucleotides tagged onto gold nanoparticles. This interaction leads to the aggregation of gold nanoparticles, and the color of the system changes from wine red to dark blue according to the abundance of miRNA. A linear correlation between fluorescence and target oligonucleotide content was obtained in the range 0.3-300 pM, along with a detection limit of 0.13 pM (n = 7) and a RSD of 3.9% (30 pM, n = 9). The present approach provides a simple, rapid, and accurate visual colorimetric assay that allows sensitive biodetection and bioanalysis of DNA and RNA nucleotides of interest in biologically important samples. Graphical abstract The colorimetric assay system for analyzing target oligonucleotides.
Shah, Manthan P; Shendell, Derek G; Meng, Qingyu; Ohman-Strickland, Pamela; Halperin, William
2018-04-23
The performances of a portable X-Ray Fluorescence (XRF) lead paint analyzer (RMD LPA-1, Protec Instrument Corp., Waltham, MA) and a commercially available colorimetric lead test kit (First Alert Lead Test Kit, eAccess Solutions, Inc., Palatine, IL) were evaluated for use by local or state health departments as potential cost-effective rapid analysis or "spot test" field techniques for tentative identification of lead content in sindoor powders. For both field-sampling methods, sensitivity, specificity and predictive values varied widely for samples containing <300,000 μg/g lead. For samples containing ≥300,000 μg/g lead, the aforementioned metrics were 100% (however, the CIs had a wide range). In addition, both field sampling methods showed clear, consistent positive readings only for samples containing ≥300,000 μg/g lead. Even samples with lead content as high as 5,110 μg/g were not positively identified by either field analysis technique. The results of this study suggest the XRF analyzer and colorimetric lead test kit cannot be used as a rapid field test for sindoor by health department inspectors.
DNA aptamer-based colorimetric detection platform for Salmonella Enteritidis.
Bayraç, Ceren; Eyidoğan, Füsun; Avni Öktem, Hüseyin
2017-12-15
Food safety is a major issue to protect public health and a key challenge is to find detection methods for identification of hazards in food. Food borne infections affects millions of people each year and among pathogens, Salmonella Enteritidis is most widely found bacteria causing food borne diseases. Therefore, simple, rapid, and specific detection methods are needed for food safety. In this study, we demonstrated the selection of DNA aptamers with high affinity and specificity against S. Enteritidis via Cell Systematic Evolution of Ligands by Exponential Enrichment (Cell-SELEX) and development of sandwich type aptamer-based colorimetric platforms for its detection. Two highly specific aptamers, crn-1 and crn-2, were developed through 12 rounds of selection with K d of 0.971µM and 0.309µM, respectively. Both aptamers were used to construct sandwich type capillary detection platforms. With the detection limit of 10 3 CFU/mL, crn-1 and crn-2 based platforms detected target bacteria specifically based on color change. This platform is also suitable for detection of S. Enteritidis in complex food matrix. Thus, this is the first to demonstrate use of Salmonella aptamers for development of the colorimetric aptamer-based detection platform in its identification and detection with naked eye in point-of-care. Copyright © 2017 Elsevier B.V. All rights reserved.
Assah, Enock; Goh, Walter; Zheng, Xin Ting; Lim, Ting Xiang; Li, Jun; Lane, David; Ghadessy, Farid; Tan, Yen Nee
2018-05-05
The tumor suppressor protein p53 plays a central role in preventing cancer through interaction with DNA response elements (REs) to regulate target gene expression in cells. Due to its significance in cancer biology, relentless efforts have been directed toward understanding p53-DNA interactions for the development of cancer therapeutics and diagnostics. In this paper, we report a rapid, label-free and versatile colorimetric assay to detect wildtype p53 DNA-binding function in complex solutions. The assay design is based on a concept that alters interparticle-distances between RE-AuNPs from a crosslinking effect induced through tetramerization of wildtype p53 protein (p53-WT) upon binding to canonical DNA motifs modified on gold nanoparticles (RE-AuNPs). This leads to a visible solution color change from red to blue, which is quantifiable by the UV- visible absorption spectra with a detection limit of 5 nM. Contrastingly, no color change was observed for the binding-deficient p53 mutants and non-specific proteins due to their inability to crosslink RE-AuNPs. Based on this sensing principle, we further demonstrate its utility for fast detection of drug-induced DNA binding function to cancer-associated Y220C mutant p53 protein using well-established reactivating compounds. By exploiting the dominant-negative property of mutant p53 over p53-WT and interactions with RE-AuNPs, this assay is configurable to detect low numbers of mutant p53 expressing cells in miniscule sample fractions obtained from typical core needle biopsy-sized tissues without signal attrition, alluding to the potential for biopsy sampling in cancer diagnostics or for defining cancer margins. This nanogold enabled colorimetric assay provides a facile yet robust method for studying important parameters influencing p53-DNA interactions with great promises for clinically pertinent applications. Copyright © 2018 Elsevier B.V. All rights reserved.
Improvement of the uric acid determination by the carbonate method for serum and urine
Eichhorn, F.; Zelmanowski, S.; Lew, E.; Rutenberg, A.; Fanias, B.
1961-01-01
An improved colorimetric procedure for determining uric acid by the carbonate method in serum and urine is described, using a 20% sodium carbonate solution with urea. Reliable results are also obtained in high concentrations of uric acid. PMID:13726059
Pérez, L M; Alvarez, B L; Codony, F; Fittipaldi, M; Adrados, B; Peñuela, G; Morató, J
2010-09-01
It is difficult to determine the effects of bactericidal compounds against bacteria in a biofilm because classical procedures for determining cell viability require several working days, multiple complicated steps and are frequently only applicable to cells in suspension. We attempt to develop a compact, inexpensive and versatile system to measure directly the extent of biofilm formation from water systems and to determine the viability of respiring bacteria in high surface biofilms. It has been reported that the reduction of tetrazolium sodium salts, such as XTT (sodium 3,3'-[1-[(phenylamino)carbonyl]-3,4-tetrazolium]Bis(4-methoxy)-6-nitro)benzene sulfonic acid hydrate), during active bacterial metabolism can be incorporated into a colorimetric method for quantifying cell viability. XTT is reduced to a soluble formazan compound during bacterial aerobic metabolism such that the amount of formazan generated is proportional to the bacterial biomass. We show here, for the first time, that this colorimetric approach can be used to determine the metabolic activity of adherent aerobic bacteria in a biofilm as a measure of cell viability. This technique has been used to estimate viability and proliferation of bacteria in suspension, but this is the first application to microbial communities in a real undisturbed biofilm. This simple new system can be used to evaluate the complex biofilm community without separating the bacteria from their support. Thus, the results obtained by this practice may be more representative of the circumstances in a natural system, opening the possibility to multiple potential applications.
This method provides a procedure for the determination of low-level orthophosphate concentrations normally found in estuarine and/or coastal waters. It is based upon the method of Murphy and Riley1 adapted for automated segmented flow analysis2 in which the two reagent solutions ...
Development of a field method for measuring manganese in welding fume.
Dale Marcy, A; Drake, Pamela L
2007-11-01
Workers who perform routine welding tasks are potentially exposed to fume that may contain manganese. Manganese may cause respiratory problems and is implicated in causing the occurrence of Parkinson-like symptoms. In this study, a field colorimetric method for extracting and measuring manganese in welding fume was developed. The method uses ultrasonic extraction with an acidic hydrogen peroxide solution to extract welding fume collected on polyvinyl chloride filters. Commercially available pre-packaged reagents are used to produce a colored solution, created by a reaction of manganese(ii) with 1-(2-pyridylazo)-2-naphthol. Absorbance measurements are then made using a portable spectrophotometer. The method detection limit and limit of quantification (LOQ) were 5.2 microg filter(-1) and 17 microg filter(-1), respectively, with a dynamic range up to 400 microg filter(-1). When the results are above the LOQ for the colorimetric method, the manganese masses are equivalent to those measured by the International Organization for Standardization Method 15202-2, which employs a strong acid digestion and analysis using inductively coupled plasma-optical emission spectrometry.
Lesniewski, Adam; Los, Marcin; Jonsson-Niedziółka, Martin; Krajewska, Anna; Szot, Katarzyna; Los, Joanna M; Niedziolka-Jonsson, Joanna
2014-04-16
Herein, we report a colorimetric immunosensor for T7 bacteriophage based on gold nanoparticles modified with covalently bonded anti-T7 antibodies. The new immunosensor allows for a fast, simple, and selective detection of T7 virus. T7 virions form immunological complexes with the antibody modified gold nanoparticles which causes them to aggregate. The aggregation can be observed with the naked eye as a color change from red to purple, as well as with a UV-vis spectrophotometer. The aggregate formation was confirmed with SEM imaging. Sensor selectivity against the M13 bacteriophage was demonstrated. The limit of detection (LOD) is 1.08 × 10(10) PFU/mL (18 pM) T7. The new method was compared with a traditional plaque test. In contrast to biological tests the colorimetric method allows for detection of all T7 phages, not only those biologically active. This includes phage ghosts and fragments of virions. T7 virus has been chosen as a model organism for adenoviruses. The described method has several advantages over the traditional ones. It is much faster than a standard plaque test. It is more robust since no bacteria-virus interactions are utilized in the detection process. Since antibodies are available for a large variety of pathogenic viruses, the described concept is very flexible and can be adapted to detect many different viruses, not only bacteriophages. Contrary to the classical immunoassays, it is a one-step detection method, and no additional amplification, e.g., enzymatic, is needed to read the result.
Detection of Bordetella pertussis by rapid-cycle PCR and colorimetric microwell hybridization.
Buck, G E
1996-01-01
The use of rapid-cycle PCR combined with colorimetric microwell hybridization for detecting Bordetella pertussis was investigated. Rapid cycling was performed with an air thermocycler (model 1605; Idaho Technology, Idaho Falls, Idaho). Although the instrument was originally designed to be used with capillary tubes, an adapter that allows this instrument to be used with PCR tubes has recently been introduced. Because of the low heat capacity of air, the thermocycler has rapid transition rates between temperatures. The combination of a rapid temperature transition rate, small sample volume (10 microliters), and overshooting or undershooting of the temperature set points allowed the cycles to be reduced to 5 s for denaturation and 10 s for extension and annealing. Thus, the amplification could be completed in a total of approximately 35 min. Amplified DNA was detected with biotin-labeled primers and by hybridization to a capture probe immobilized in microwell plates. When simulated clinical specimens consisting of pooled nasopharyngeal washes with known numbers of B. pertussis organisms were examined by this procedure, as little as one organism per 5 microliters of sample could be detected. Six nasopharyngeal aspirates or washes from culture-positive patients were positive by PCR, as were two of seven specimens obtained from patients that were negative by culture and direct fluorescent-antibody assay. The two patients who were PCR positive but culture and direct fluorescent-antibody assay negative had clinical disease compatible with pertussis. This method appears to be a sensitive, convenient means of detecting B. pertussis in clinical specimens. The total time required for specimen processing, amplification, and detection is about 2.5 h. PMID:8735080
Spatial variation in carrier dynamics along a single CdSSe nanowire
NASA Astrophysics Data System (ADS)
Blake, Jolie C.; Eldridge, Peter S.; Gundlach, Lars
2014-10-01
Ultrafast charge carrier dynamics along individual CdSxSe1-x nanowires has been measured. The use of an improved ultrafast Kerr-gated microscope allows for spatially resolved luminescence measurements along a single nanowire. Amplified spontaneous emission (ASE) was observed at high excitation fluences. Position dependent variations of ultrafast ASE dynamics were observed. SEM and colorimetric measurements showed that the difference in dynamics can be attributed to variations in non-radiative recombination rates along the wire. The dominant Shockley-Read recombination rate can be extracted from ASE dynamics and can be directly related to charge carrier mobility and defect density. Employing ASE as a probe for defect densities provides a new sub-micron spatially resolved, contactless method for measurements of charge carrier mobility.
Siangproh, Weena; Somboonsuk, Thachkorn; Chailapakul, Orawan; Songsrirote, Kriangsak
2017-11-01
A simple, rapid, sensitive, and economical method based on colorimetry for the determination of paraquat, a widely used herbicide, was developed. Citrate-coated silver nanoparticles (AgNPs) were synthesized as the colorimetric probe. The mechanism of the assay is related to the aggregation of negatively charged AgNPs as induced by positively-charged paraquat resulting from coulombic attraction which causes the color to change from a deep greenish yellow to pale yellow in accordance with the concentrations of paraquat. Silica gel was exploited as the paraquat adsorbent for purification and pre-concentration prior to the direct determination with negatively charged AgNPs without the requirement of the elution step. The validity of the proposed approach was evaluated by spiking standard paraquat in water and plant samples. Recoveries of paraquat in water samples were 93.6% and 95.4% for groundwater and canal water, respectively, while those in plant samples were 89.5% and 86.6% for Chinese cabbage and green apple, respectively,after using the optimized extraction procedure. The absorbance of AgNPs at 400nm was linearly related to the concentration of paraquat over the range of 0.05-50mgL -1 , with detection limits of 0.05mgL -1 for water samples, and 0.10mgL -1 for plant samples by naked eye determination. Copyright © 2017 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Amini, Bahram; Kamali, Mehdi; Salouti, Mojtaba; Yaghmaei, Parichehreh
2018-06-01
Colorimetric DNA detection is preferred over other methods for clinical molecular diagnosis because it does not require expensive equipment. In the present study, the colorimetric method based on gold nanoparticles (GNPs) and endonuclease enzyme was used for the detection of P. aeruginosa ETA gene. Firstly, the primers and probe for P. aeruginosa exotoxin A (ETA) gene were designed and checked for specificity by the PCR method. Then, GNPs were synthesized using the citrate reduction method and conjugated with the prepared probe to develop the new nano-biosensor. Next, the extracted target DNA of the bacteria was added to GNP-probe complex to check its efficacy for P. aeruginosa ETA gene diagnosis. A decrease in absorbance was seen when GNP-probe-target DNA cleaved into the small fragments of BamHI endonuclease due to the weakened electrostatic interaction between GNPs and the shortened DNA. The right shift of the absorbance peak from 530 to 562 nm occurred after adding the endonuclease. It was measured using a UV-VIS absorption spectroscopy that indicates the existence of the P. aeruginosa ETA gene. Sensitivity was determined in the presence of different concentrations of target DNA of P. aeruginosa. The results obtained from the optimized conditions showed that the absorbance value has linear correlation with concentration of target DNA (R: 0.9850) in the range of 10-50 ng mL-1 with the limit detection of 9.899 ng mL-1. Thus, the specificity of the new method for detection of P. aeruginosa was established in comparison with other bacteria. Additionally, the designed assay was quantitatively applied to detect the P. aeruginosa ETA gene from 103 to 108 CFU mL-1 in real samples with a detection limit of 320 CFU mL-1.
Rezaeian, Mohammad; Beakes, Gordon W; Parker, David S
2004-10-01
Anaerobic fungi were isolated from both the rumen and faeces of nine sheep and a cow. A reliable and simple method for the isolation of anaerobic fungi using 24 h rumen incubated milled straw as the inoculum source was developed. We also evaluate the use of chitin measurements as an assay of rumen fungal biomass. Chitin levels were determined from various sample sources (milled barley straw used as the fungal culture substrate in vitro; plant particulate digests from the rumen (PLP) and centrifuged strained rumen fluid (CSRF) using both HPLC and colorimetric methods. Both methods were highly correlated and consequently the simpler colorimetric method was adopted for subsequent studies. There was also a high degree of correlation between anaerobic fungal cellulase activities with the assayed chitin content of milled barley straw cultures over 12 d of an in vitro experiment. The colorimetric chitin assay protocol was then used to assess the diurnal variation and abundance of rumen fungi in in vivo assays. We assessed the distribution of chitin (mg g(-1) dry matter) in various fractions of the strained rumen fluid (SRF) and PLP samples from the rumen of sheep. Chitin was detected in all fractions of strained rumen fluid but the main source of chitin in the samples may be attributed to the fungal biomass. We did not detect any significant differences in chitin levels over a 24 h sampling period. Finally, an SEM study on subsamples of milled straw and plant particulate matter used in the chitin assays, revealed that the pattern of the fungal development on substrate material differs from the culture medium to the rumen.
Color rendering indices in global illumination methods
NASA Astrophysics Data System (ADS)
Geisler-Moroder, David; Dür, Arne
2009-02-01
Human perception of material colors depends heavily on the nature of the light sources used for illumination. One and the same object can cause highly different color impressions when lit by a vapor lamp or by daylight, respectively. Based on state-of-the-art colorimetric methods we present a modern approach for calculating color rendering indices (CRI), which were defined by the International Commission on Illumination (CIE) to characterize color reproduction properties of illuminants. We update the standard CIE method in three main points: firstly, we use the CIELAB color space, secondly, we apply a Bradford transformation for chromatic adaptation, and finally, we evaluate color differences using the CIEDE2000 total color difference formula. Moreover, within a real-world scene, light incident on a measurement surface is composed of a direct and an indirect part. Neumann and Schanda1 have shown for the cube model that interreflections can influence the CRI of an illuminant. We analyze how color rendering indices vary in a real-world scene with mixed direct and indirect illumination and recommend the usage of a spectral rendering engine instead of an RGB based renderer for reasons of accuracy of CRI calculations.
Tivana, Lucas Daniel; Da Cruz Francisco, Jose; Zelder, Felix; Bergenståhl, Bjorn; Dejmek, Petr
2014-09-01
In this study, we extend pioneering studies and demonstrate straightforward applicability of the corrin-based chemosensor, aquacyanocobyrinic acid (ACCA), for the instantaneous detection and rapid quantification of endogenous cyanide in fresh and processed cassava roots. Hydrolytically liberated endogenous cyanide from cyanogenic glycosides (CNp) reacts with ACCA to form dicyanocobyrinic acid (DCCA), accompanied by a change of colour from orange to violet. The method was successfully tested on various cassava samples containing between 6 and 200 mg equiv. HCN/kg as verified with isonicotinate/1,3-dimethylbarbiturate as an independent method. The affinity of ACCA sensor to cyanide is high, coordination occurs fast and the colorimetric response can therefore be instantaneously monitored with spectrophotometric methods. Direct applications of the sensor without need of extensive and laborious extraction processes are demonstrated in water-extracted samples, in acid-extracted samples, and directly on juice drops. ACCA showed high precision with a standard deviation (STDV) between 0.03 and 0.06 and high accuracy (93-96%). Overall, the ACCA procedure is straightforward, safe and easily performed. In a proof-of-concept study, rapid screening of ten samples within 20 min has been tested. Copyright © 2014 Elsevier Ltd. All rights reserved.
Dawson, Verdel K.; Meinertz, Jeffery R.; Schmidt, Larry J.; Gingerich, William H.
2003-01-01
Concentrations of chloramine-T must be monitored during experimental treatments of fish when studying the effectiveness of the drug for controlling bacterial gill disease. A surrogate analytical method for analysis of chloramine-T to replace the existing high-performance liquid chromatography (HPLC) method is described. A surrogate method was needed because the existing HPLC method is expensive, requires a specialist to use, and is not generally available at fish hatcheries. Criteria for selection of a replacement method included ease of use, analysis time, cost, safety, sensitivity, accuracy, and precision. The most promising approach was to use the determination of chlorine concentrations as an indicator of chloramine-T. Of the currently available methods for analysis of chlorine, the DPD (N,N-diethyl-p-phenylenediamine) colorimetric method best fit the established criteria. The surrogate method was evaluated under a variety of water quality conditions. Regression analysis of all DPD colorimetric analyses with the HPLC values produced a linear model (Y=0.9602 X+0.1259) with an r2 value of 0.9960. The average accuracy (percent recovery) of the DPD method relative to the HPLC method for the combined set of water quality data was 101.5%. The surrogate method was also evaluated with chloramine-T solutions that contained various concentrations of fish feed or selected densities of rainbow trout. When samples were analyzed within 2 h, the results of the surrogate method were consistent with those of the HPLC method. When samples with high concentrations of organic material were allowed to age more than 2 h before being analyzed, the DPD method seemed to be susceptible to interference, possibly from the development of other chloramine compounds. However, even after aging samples 6 h, the accuracy of the surrogate DPD method relative to the HPLC method was within the range of 80–120%. Based on the data comparing the two methods, the U.S. Food and Drug Administration has concluded that the DPD colorimetric method is appropriate to use to measure chloramine-T in water during pivotal efficacy trials designed to support the approval of chloramine-T for use in fish culture.
NASA Astrophysics Data System (ADS)
Pelin, V.; Rusu, O.; Sandu, I.; Vasilache, V.; Gurlui, S.; Sandu, A. V.; Cazacu, M. M.; Sandu, I. G.
2017-06-01
According to the scientific literature, the pollution phenomenon is strongly related by the urban activity from the last decades, with direct effects on the state of conservation of the stone constructions also. This paper presents a preliminary study on the colorimetric evolution of the lithic surfaces exposed under strongly traffic influence from the urban microclimate conditions. The analysed lithic surfaces are similar with the building stone from the structure of an historical monument (from 19th century), such as the Stone Bridge in Iasi-Romania, located in the immediate vicinity of the roadside loop with the same name. The colour change monitoring for the above-mentioned geomaterials aims at anticipating the effects of postponing the decongestion of car traffic and implicitly initiating the assessment of the effects of pollution over this historic monument, which is in an advanced state of deterioration and degradation.
Fu, Qianqian; Zhu, Biting; Ge, Jianping
2017-02-16
A SiO 2 colloidal photonic crystal film with a hierarchical porous structure is fabricated to demonstrate an integrated separation and colorimetric detection of chemical species for the first time. This new photonic crystal based thin layer chromatography process requires no dyeing, developing and UV irradiation compared to the traditional TLC. The assembling of mesoporous SiO 2 particles via a supersaturation-induced-precipitation process forms uniform and hierarchical photonic crystals with micron-scale cracks and mesopores, which accelerate the diffusion of developers and intensify the adsorption/desorption between the analytes and silica for efficient separation. Meanwhile, the chemical substances infiltrated to the voids of photonic crystals cause an increase of the refractive index and a large contrast of structural colors towards the unloaded part, so that the sample spots can be directly recognized with the naked eye before and after separation.
Determination of small and large amounts of fluorine in rocks
Grimaldi, F.S.; Ingram, B.; Cuttitta, F.
1955-01-01
Gelatinous silica and aluminum ions retard the distillation of fluorine in the Willard and Winter distillation method. A generally applicable, simple method for the determination of fluorine in rocks containing aluminum or silicon or both as major constituents was desired. In the procedure developed, the sample is fused with a mixture of sodium carbonate and zinc oxide, leached with water, and filtered. The residue is granular and retains nearly all of the silica. The fluorine in the filtrate is distilled directly from a perchloric acid-phosphoric acid mixture. Phosphoric acid permits the quantitative distillation of fluorine in the presence of much aluminum at the usual distillation temperature and without the collection of large volumes of distillate. The fluorine is determined either by microtitration with thorium nitrate or colorimetrically with thoron. The procedure is rapid and has yielded excellent results on silicate rocks and on samples from the aluminum phosphate (leached) zone of the Florida phosphate deposits.
Wongniramaikul, Worawit; Limsakul, Wadcharawadee; Choodum, Aree
2018-05-30
A biodegradable colorimetric film was fabricated on the lid of portable tube for in-tube formaldehyde detection. Based on the entrapment of colorimetric reagents within a thin film of tapioca starch, the yellow reaction product was observed with formaldehyde. Intensity of the blue channel from the digital image of yellow product showed a linear relationship in the range of 0-25 mg L -1 with low detection limit of 0.7 ± 0.1 mg L -1 . Inter-day precision of 0.61-3.10%RSD were obtained with less than 4.2% relative error from control samples. The developed method was applied for various food samples in Phuket and formaldehyde concentration range was non-detectable to 1.413 mg kg -1 . The quantified concentrations of formaldehyde in fish and squid samples provided relative errors of -7.7% and +10.8% compared to spectrophotometry. This low cost sensor (∼0.04 USD/test) with digital image colorimetry was thus an effective alternative for formaldehyde detection in food sample. Copyright © 2018 Elsevier Ltd. All rights reserved.
Wang, Yi-Wei; Wang, Meili; Wang, Lixing; Xu, Hui; Tang, Shurong; Yang, Huang-Hao; Zhang, Lan; Song, Hongbo
2017-11-02
In this work, uniformly-dispersed platinum nanoparticles (PtNPs) were synthesized by a simple chemical reduction method, in which citric acid and sodium borohydride acted as a stabilizer and reducer, respectively. An ultrasensitive colorimetric sensor for the facile and rapid detection of Ag⁺ ions was constructed based on the peroxidase mimetic activities of the obtained PtNPs, which can catalyze the oxidation of 3,3',5,5'-tetramethylbenzidine (TMB) by H₂O₂ to produce colored products. The introduced Ag⁺ would be reduced to Ag⁰ by the capped citric acid, and the deposition of Ag⁰ on the PtNPs surface, can effectively inhibit the peroxidase-mimetic activity of PtNPs. Through measuring the maximum absorption signal of oxidized TMB at 652 nm, ultra-low detection limits (7.8 pM) of Ag⁺ can be reached. In addition to such high sensitivity, the colorimetric assay also displays excellent selectivity for other ions of interest and shows great potential for the detection of Ag⁺ in real water samples.
O'Sullivan, N A; Fallon, R; Carroll, C; Smith, T; Maher, M
2000-02-01
Campylobacter enteritis in humans has been linked to consumption of poultry meat. Surveys show that 30-100% of poultry harbour Campylobacter as normal flora of the digestive tract which indicates a need to identify prevalent organism types in flocks and trace their epidemiology. In this study we describe a Campylobacter genus specific polymerase chain reaction (PCR) assay, amplifying the 16 S-23 S rRNA intergenic spacer region with an internal Campylobacter genus specific DNA probe and species specific probes for Campylobacter jejuni and Campylobacter coli designed for confirmation of the amplified PCR products by Southern blot and colorimetric reverse hybridization assays. The specificity of this assay was established by testing a range of food pathogens. Broiler chicken samples were tested following presumptive positive identification by the Malthus System V analyser (Malthus Instruments, UK). The combined PCR and colorimetric reverse hybridization assay is easy to perform and faster than conventional methods for confirmation and identification of Campylobacter species. Copyright 2000 Academic Press.
NASA Astrophysics Data System (ADS)
Alizadeh, A.; Khodaei, M. M.; Karami, Ch; Workentin, M. S.; Shamsipur, M.; Sadeghi, M.
2010-08-01
A gold nanoparticle (AuNPs)-based simple and fast colorimetric sensor for selective detecting of Pb(II) in aqueous solution has been developed. Monodisperse AuNPs (approx. 2.0 nm diameter) has been prepared facilely and further modified with an alkanethiol-bearing monoazacrown ether terminus. These AuNPs are shown to selectively sense Pb2 + through color change, which is visually discernible by an appearance of the surface plasmon band (SPB) at 520 nm. The recognition mechanism is attributed to the unique structure of the monoazacrown ether attached to AuNPs and metal sandwich coordination between two azacrown ether moieties that are attached to separate nanoparticles. This inter-particle cross-linking results in an aggregation and apparent color change from brown to purple. Additionally, TEM experiments support the optical absorption data proving the aggregation between azacrown ether-capped gold nanoparticles. This AuNP-based colorimetric assay is a facile and robust method and allows fast detection of Pb2 + at ambient temperatures. More importantly, the developed technique does not utilize enzymatic reactions, light-sensitive dye molecules, lengthy protocols or sophisticated instrumentation.
NASA Astrophysics Data System (ADS)
Anekthirakun, Pimpimon; Sukwattanasinitt, Mongkol; Tuntulani, Thawatchai; Imyim, Apichat
2013-07-01
The colorimetric response (CR) of poly(10,12-pentacosadiynoic acid) vesicles (PPCDA) induced by α-cyclodextrin (α-CD) in an aqueous solution has been studied. Various parameters affecting the CR, such as response time and concentration were investigated. The blue color of 0.01 mM PPCDA solution became pinkish red with the addition of α-CD at the concentration higher than 3 mM. The inhibition of the color transition from blue to red was investigated using 11 phenolic compounds. The color transition could be inhibited and observed by naked eye in the presence of 4 phenolic compounds, i.e. 4-nitrophenol (4-NP) and 4-bromophenol (4-BP) and 4-chlorophenol (4-CP) and 3-nitrophenol (3-NP). A colorimetric method for the determination of these compounds was validated and applied for surface water analysis. The linear range from the plot of CR against phenolic compounds concentration was in the order of 0.5-2.0 mM with R2 more than 0.99. The recoveries were 90-95% with good precision (1-4%RSD, n = 10).
Trinder, P.; Harper, F. E.
1962-01-01
A colorimetric technique for the determination of carboxyhaemoglobin in blood is described. Carbon monoxide released from blood in a standard Conway unit reacts with palladous chloride/arsenomolybdate solution to produce a blue colour. Using 0·5 to 2 ml. of blood, the method will estimate carboxyhaemoglobin accurately at levels from 0·1% to 100% of total haemoglobin and in the presence of other abnormal pigments. A number of methods are available for the determination of carboxyhaemoglobin; none is accurate below a concentration of 1·5 g. carboxyhaemoglobin per 100 ml. but for most clinical purposes this is not important. For forensic purposes and occasionally in clinical use, an accurate determination of carboxyhaemoglobin below 750 mg. per 100 ml. may be required and no really satisfactory method is at present available. Some time ago when it was important to know whether a person who was found dead in a burning house had died before or after the fire had started, we became interested in developing a method which would determine accurately carboxyhaemoglobin at levels of 750 mg. per 100 ml. PMID:13922505
Automated method for study of drug metabolism
NASA Technical Reports Server (NTRS)
Furner, R. L.; Feller, D. D.
1973-01-01
Commercially available equipment can be modified to provide automated system for assaying drug metabolism by continuous flow-through. System includes steps and devices for mixing drug with enzyme and cofactor in the presence of pure oxygen, dialyzing resulting metabolite against buffer, and determining amount of metabolite by colorimetric method.
REDUCTION OF NITRATE THROUGH THE USE OF NITRATE REDUCTASE FOR THE SMARTCHEM AUTOANALYZER
The standard method for the determination of nitrate in drinking water, USEPA Method 353.2 Determination of Nitrate-Nitrite by Automated Colorimetry, employs cadmium as the reductant for the conversion of nitrate to nitrite. The nitrite is then analyzed colorimetrically by way ...
NASA Astrophysics Data System (ADS)
Shahrivari, Shima; Faridbod, Farnoush; Ganjali, Mohammad Reza
2018-02-01
In this work, a rapid, selective naked eyes colorimetric chemical probe for the detection of Cr3 + was developed based on functionalization of gold nanoparticles. For this purpose, surface of Au NPs was functionalized using 4-amino-5-methyl-4H-1,2,4-triazole-3-thiol (AMTT). Through colorimetric studies, it was found that in the presence of Cr3 + ions, AMTT-Au NPs instantly aggregated and resulted in a color change of the solution from red to blue. The color change of AMTT-Au NPs due to the aggregation induced by Cr3 + can be seen with even naked eyes and also by UV-Vis spectroscopy with a detection limit of 1.8 μM and 0.1 μM, respectively. AMTT-Au NPs showed excellent selectivity toward Cr3 + compared to other cations tested, including K+, Na+, Cs+, Fe3 +, Ni2 +, Cu2 +, Co2 +, Zn2 +, Ba2 +, Ca2 +, Mg2 +, Cd2 +, Pb2 +, Hg2 + ions and especially all trivalent lanthanide ions. The absorbance ratio (A650/A525) was linear toward Cr3 + concentrations in the range of 0.6-6.1 μM (R2 = 0.996). The best response was achieved over a pH range of 3-5. Furthermore, the proposed colorimetric method based on AMTT-Au NPs was successfully used for Cr3 + ion detection in plasma sample and some water samples.
Colorimetric carbon dioxide detector to determine accidental tracheal feeding tube placement.
Howes, Daniel W; Shelley, Eric S; Pickett, William
2005-04-01
To determine the accuracy of colorimetric CO2 detection compared to the reference standard two-step radiological confirmation of feeding tube position. A prospective study was conducted with patients presenting to a 21-bed medical-surgical intensive care unit. An adapter was developed using an endotracheal tube adapter to connect a colorimetric CO2 detector to a feeding tube in an airtight manner. In part I of the study a feeding tube connected to the colorimeter was inserted into the endotracheal tubes of ten ventilated patients to test the device's ability to detect tracheal placement. In part II patients undergoing feeding tube insertion had tube position confirmed with the colorimeter as well as the reference standard two-step x-ray. In phase I the colorimeter correctly identified tracheal placement in all ten patients. In phase II 93/100 procedures ultimately were eligible; the colorimeter had a sensitivity of 0.88 (95% confidence interval: 0.65-1.00) and specificity of 0.99 (0.97-1.00). The device missed one of the eight tracheal placements. Agreement between the colorimeter and two-step x-ray interpretations was excellent (Kappa 0.86; standard error 0.10). We describe a novel, convenient method to confirm esophageal feeding tube placement. The device is easily assembled and inexpensive, but should not be reused. Colorimetric determination of tracheal feeding tube placement with this device has excellent agreement with the reference standard two-step radiological technique.
Smartphone-based colorimetric analysis for detection of saliva alcohol concentration.
Jung, Youngkee; Kim, Jinhee; Awofeso, Olumide; Kim, Huisung; Regnier, Fred; Bae, Euiwon
2015-11-01
A simple device and associated analytical methods are reported. We provide objective and accurate determination of saliva alcohol concentrations using smartphone-based colorimetric imaging. The device utilizes any smartphone with a miniature attachment that positions the sample and provides constant illumination for sample imaging. Analyses of histograms based on channel imaging of red-green-blue (RGB) and hue-saturation-value (HSV) color space provide unambiguous determination of blood alcohol concentration from color changes on sample pads. A smartphone-based sample analysis by colorimetry was developed and tested with blind samples that matched with the training sets. This technology can be adapted to any smartphone and used to conduct color change assays.
Silva, Thalita G; de Araujo, William R; Muñoz, Rodrigo A A; Richter, Eduardo M; Santana, Mário H P; Coltro, Wendell K T; Paixão, Thiago R L C
2016-05-17
We report the development of a simple, portable, low-cost, high-throughput visual colorimetric paper-based analytical device for the detection of procaine in seized cocaine samples. The interference of most common cutting agents found in cocaine samples was verified, and a novel electrochemical approach was used for sample pretreatment in order to increase the selectivity. Under the optimized experimental conditions, a linear analytical curve was obtained for procaine concentrations ranging from 5 to 60 μmol L(-1), with a detection limit of 0.9 μmol L(-1). The accuracy of the proposed method was evaluated using seized cocaine samples and an addition and recovery protocol.
USDA-ARS?s Scientific Manuscript database
Shiga-toxin producing Escherichia coli (STEC) strains (“Big Six” – O26, O45, O103, O111, O121, O145, and O157) represent significant groups of pathogens responsible for foodborne diseases. The objective of this study was to develop a colorimetric optical sensing assay that can simultaneously detect ...
NASA Astrophysics Data System (ADS)
Khezri, Somayeh; Bahram, Morteza; Samadi, Naser
2018-01-01
In this paper, we describe a rapid, low-cost and highly sensitive colorimetric method for the detection of isoprenaline, based on 2-amino-5-mercapto-1,3,4-thiadiazol (AMTD) functionalized gold nanoparticles (AMTD-AuNPs) as a sensing element. Hydrogen bonding interaction between isoprenaline and AMTD resulted in the aggregation of AuNPs and a consequent color change of AuNPs from red to blue. The concentration of isoprenaline could be detected with the naked eye or a UV-visible spectrometer. Results showed that the absorbance ratio (A650/A524) was linear with isoprenaline concentrations in the range of 0.2 to 2.6 μM (R = 0.997). The detection limit of this method was 0.08 μM. The proposed method is simple, without using complicated instruments and adding salts for enhancing sensitivity. This probe could be successfully applied to the determination of isoprenaline in human serum samples and urine samples after deproteinization.
Srirangsan, Paveena; Hamada-Sato, Naoko; Kawai, Kiyoshi; Watanabe, Manabu; Suzuki, Toru
2010-12-08
Alkaline phosphatase (ALP), nucleoside phosphorylase (NP), and xanthine oxidase (XOD) were used in a colorimetric method for evaluation of fish freshness based on the Ki value. Two enzyme mixtures, NP-XOD and ALP-NP-XOD, were prepared with a color developing agent, and stabilities of the enzymes were improved by freeze-drying with glass-forming additives, i.e., sucrose and sucrose-gelatin. As a result, a linear relationship was obtained between the Ki values determined by the developed colorimetric method and a conventional high-performance liquid chromatography with a high correlation coefficient of 0.997. All enzyme samples containing the additive(s) were amorphous, and higher enzymes activities were maintained compared to those freeze-dried without an additive. Sucrose-gelatin/enzyme mixtures showed higher glass transition temperature; consequently, the enzymes were better stabilized than the sucrose/enzyme formulations. Using the sucrose-gelatin/enzyme mixture, Ki values of fish meat could be accurately determined even after 6-month storage of the dried enzymes at 40 °C.
Erçağ, Erol; Uzer, Ayşem; Apak, Reşat
2009-05-15
Because of the extremely heterogeneous distribution of explosives in contaminated soils, on-site colorimetric methods are efficient tools to assess the nature and extent of contamination. To meet the need for rapid and low-cost chemical sensing of explosive traces or residues in soil and post-blast debris, a colorimetric absorption-based sensor for trinitrotoluene (TNT) determination has been developed. The charge-transfer (CT) reagent (dicyclohexylamine, DCHA) is entrapped in a polyvinylchloride (PVC) polymer matrix plasticised with dioctylphtalate (DOP), and moulded into a transparent sensor membrane sliced into test strips capable of sensing TNT showing an absorption maximum at 530 nm when placed in a 1-mm spectrophotometer cell. The sensor gave a linear absorption response to 5-50 mg L(-1) TNT solutions in 30% aqueous acetone with limit of detection (LOD): 3 mg L(-1). The sensor is only affected by tetryl, but not by RDX, pentaerythritoltetranitrate (PETN), dinitrotoluene (DNT), and picric acid. The proposed method was statistically validated for TNT assay against high performance liquid chromatography (HPLC) using a standard sample of Comp B. The developed sensor was relatively resistant to air and water, was of low-cost and high specificity, gave a rapid and reproducible response, and was suitable for field use of TNT determination in both dry and humid soil and groundwater with a portable colorimeter.
Sergeyeva, T A; Gorbach, L A; Piletska, E V; Piletsky, S A; Brovko, O O; Honcharova, L A; Lutsyk, O D; Sergeeva, L M; Zinchenko, O A; El'skaya, A V
2013-04-03
An easy-to-use colorimetric test-system for the efficient detection of creatinine in aqueous samples was developed. The test-system is based on composite molecularly imprinted polymer (MIP) membranes with artificial receptor sites capable of creatinine recognition. A thin MIP layer was created on the surface of microfiltration polyvinylidene fluoride (PVDF) membranes using method of photo-initiated grafting polymerization. The MIP layer was obtained by co-polymerization of a functional monomer (e.g. 2-acrylamido-2-methyl-1-propanesulfonic acid, itaconic acid or methacrylic acid) with N, N'-methylenebisacrylamide as a cross-linker. The choice of the functional monomer was based on the results of computational modeling. The creatinine-selective composite MIP membranes were used for measuring creatinine in aqueous samples. Creatinine molecules were selectively adsorbed by the MIP membranes and quantified using color reaction with picrates. The intensity of MIP membranes staining was proportional to creatinine concentration in an analyzed sample. The colorimetric test-system based on the composite MIP membranes was characterized with 0.25 mM detection limit and 0.25-2.5mM linear dynamic range. Storage stability of the MIP membranes was estimated as at least 1 year at room temperature. As compared to the traditional methods of creatinine detection the developed test-system is characterized by simplicity of operation, small size and low cost. Copyright © 2013 Elsevier B.V. All rights reserved.
Erel, Ozcan
2004-04-01
To develop a novel colorimetric and automated direct measurement method for total antioxidant capacity (TAC). A new generation, more stable, colored 2,2'-azinobis-(3-ethylbenzothiazoline-6-sulfonic acid radical cation (ABTS(*+)) was employed. The ABTS(*+) is decolorized by antioxidants according to their concentrations and antioxidant capacities. This change in color is measured as a change in absorbance at 660 nm. This process is applied to an automated analyzer and the assay is calibrated with Trolox. The novel assay is linear up to 6 mmol Trolox equivalent/l, its precision values are lower than 3%, and there is no interference from hemoglobin, bilirubin, EDTA, or citrate. The method developed is significantly correlated with the Randox- total antioxidant status (TAS) assay (r = 0.897, P < 0.0001; n = 91) and with the ferric reducing ability of plasma (FRAP) assay (r = 0.863, P < 0.0001; n = 110). Serum TAC level was lower in patients with major depression (1.69 +/- 0.11 mmol Trolox equivalent/l) than in healthy subjects (1.75 +/- 0.08 mmol Trolox equivalent/l, P = 0.041). This easy, stable, reliable, sensitive, inexpensive, and fully automated method described can be used to measure total antioxidant capacity.
da Silva, Gabriela O; de Araujo, William R; Paixão, Thiago R L C
2018-01-01
An office paper-based colorimetric device is proposed as a portable, rapid, and low-cost sensor for forensic applications aiming to detect phenacetin used as adulterant in illicit seized materials such as cocaine. The proposed method uses white office paper as the substrate and wax printing technology to fabricate the detection zones. Based on the optimum conditions, a linear analytical curve was obtained for phenacetin concentrations ranging from 0 to 64.52µgmL ‒1 , and the straight line was in accordance with the following equation: (Magenta percentage color) = 1.19 + 0.458 (C Phe /µgmL ‒1 ), R 2 = 0.990. The limit of detection was calculated as 3.5µgmL ‒1 (3σ/slope). The accuracy of the proposed method was evaluated using real seized cocaine samples and the spike-recovery procedure. Copyright © 2017 Elsevier B.V. All rights reserved.
Colorimetric analysis of pigmented skin lesions: a pilot study with the Visi-Chroma VC-100 device.
Vereecken, P; Mommaerts, M; Duez, C; Petein, M; Laporte, M; Hubinon, J-L; Heenen, M
2006-01-01
Definition of the colour of pigmented skin lesions (PSLs) with the naked eye remains subjective and may be influenced by lighting. This problem underlines the usefulness of instrumental assessments such as epiluminescence microscopy and colorimetric devices. We describe here a new method of colour analysis of PSLs with the Visi-Chroma VC-100 device, which illuminates the surface of the skin with white light-emitting diodes (LEDs) and analyses the reflected light by a red-green-blue (RGB) charge-coupled device (CCD) colour camera. Twenty-one PSLs to be excised for cosmetic or medical reasons were analysed by this device with clinicopathological correlation. This method is feasible and might be useful to assess the colour of PSLs and allow comparisons for changes over time. Further studies are needed to determine the usefulness of this device in clinical practice.
Colorimetric As (V) detection based on S-layer functionalized gold nanoparticles.
Lakatos, Mathias; Matys, Sabine; Raff, Johannes; Pompe, Wolfgang
2015-11-01
Herein, we present simple and rapid colorimetric and UV/VIS spectroscopic methods for detecting anionic arsenic (V) complexes in aqueous media. The methods exploit the aggregation of S-layer-functionalized spherical gold nanoparticles of sizes between 20 and 50 nm in the presence of arsenic species. The gold nanoparticles were functionalized with oligomers of the S-layer protein of Lysinibacillus sphaericus JG-A12. The aggregation of the nanoparticles results in a color change from burgundy-red for widely dispersed nanoparticles to blue for aggregated nanoparticles. A detailed signal analysis was achieved by measuring the shift of the particle plasmon resonance signal with UV/VIS spectroscopy. To further improve signal sensitivity, the influence of larger nanoparticles was tested. In the case of 50 nm gold nanoparticles, a concentration of the anionic arsenic (V) complex lower than 24 ppb was detectable. Copyright © 2015 Elsevier B.V. All rights reserved.
Telling, G M; Dunnett, P C
1981-10-01
Synopsis A technique is described for the rapid determination of N-nitrosodiethanolamine (NDELA) in shampoos, skin creams and similar products based on aqueous extraction, partition into ethyl acetate and colorimetric determination using the Eisenbrand-Preussman cleavage reaction. Recoveries of NDELA added at levels of 5-100 mug kg(-1) to a range of shampoo and cream types ranged from 90-101%. The limit of determination for the method is 2.5 mug kg(-1). Observations on the application of a thermal energy analyser linked to a gas chromatograph are also reported. Application of the technique to a survey of a wide range of shampoo and skin cream types showed that levels of total N-nitroso compounds were less than 30 mug kg(-1) in < 90% of samples and, in many cases, less than 2.5 mug kg-1.
Real-time color measurement using active illuminant
NASA Astrophysics Data System (ADS)
Tominaga, Shoji; Horiuchi, Takahiko; Yoshimura, Akihiko
2010-01-01
This paper proposes a method for real-time color measurement using active illuminant. A synchronous measurement system is constructed by combining a high-speed active spectral light source and a high-speed monochrome camera. The light source is a programmable spectral source which is capable of emitting arbitrary spectrum in high speed. This system is the essential advantage of capturing spectral images without using filters in high frame rates. The new method of real-time colorimetry is different from the traditional method based on the colorimeter or the spectrometers. We project the color-matching functions onto an object surface as spectral illuminants. Then we can obtain the CIE-XYZ tristimulus values directly from the camera outputs at every point on the surface. We describe the principle of our colorimetric technique based on projection of the color-matching functions and the procedure for realizing a real-time measurement system of a moving object. In an experiment, we examine the performance of real-time color measurement for a static object and a moving object.
Mustafa, Ahmad; Karmali, Amin; Abdelmoez, Wael
2016-01-01
The present work involves a sensitive high-throughput microtiter plate based colorimetric assay for estimating lipase activity using cupric acetate pyridine reagent (CAPR). In the first approach, three factors two levels factorial design methodology was used to evaluate the interactive effect of different parameters on the sensitivity of the assay method. The optimization study revealed that the optimum CAPR concentration was 7.5% w/v, the optimum solvent was heptane and the optimum CAPR pH was 6. In the second approach, the optimized colorimetric microplate assay was used to measure lipase activity based on enzymatic hydrolysis of olive oil emulsion substrate at 37°C and 150 rpm. The emulsion substrates were formulated by using olive oil, triton X-100 (10% v/v in pH 8) and sodium phosphate buffer of pH 8 in ratio of 1:1:1 in the case of Candida sp. lipase. While in the case of immobilized lipozyme RMIM, The emulsion substrates were formulated by using olive oil, triton X-100 (1% v/v in pH 8) and sodium phosphate buffer of pH 8 in ratio of 2:1:1. Absorbance was measured at 655 nm. The stability of this assay (in terms of colored heptane phase absorbance readings) retained more than 92.5% after 24 h at 4°C compared to the absorbance readings measured at zero time. In comparison with other lipase assay methods, beside the developed sensitivity, the reproducibility and the lower limit of detection (LOD) of the proposed method, it permits analyzing of 96 samples at one time in a 96-well microplate. Furthermore, it consumes small quantities of chemicals and unit operations.
NASA Astrophysics Data System (ADS)
Oleszko, Adam; Hartwich, Jadwiga; Wójtowicz, Anna; Gąsior-Głogowska, Marlena; Huras, Hubert; Komorowska, Małgorzata
2017-08-01
Hypertriglyceridemia, related with triglyceride (TG) in plasma above 1.7 mmol/L is one of the cardiovascular risk factors. Very low density lipoproteins (VLDL) are the main TG carriers. Despite being time consuming, demanding well-qualified staff and expensive instrumentation, ultracentrifugation technique still remains the gold standard for the VLDL isolation. Therefore faster and simpler method of VLDL-TG determination is needed. Vibrational spectroscopy, including FT-IR and Raman, is widely used technique in lipid and protein research. The aim of this study was assessment of Raman and FT-IR spectroscopy in determination of VLDL-TG directly in serum with the isolation step omitted. TG concentration in serum and in ultracentrifugated VLDL fractions from 32 patients were measured with reference colorimetric method. FT-IR and Raman spectra of VLDL and serum samples were acquired. Partial least square (PLS) regression was used for calibration and leave-one-out cross validation. Our results confirmed possibility of reagent-free determination of VLDL-TG directly in serum with both Raman and FT-IR spectroscopy. Quantitative VLDL testing by FT-IR and/or Raman spectroscopy applied directly to maternal serum seems to be promising screening test to identify women with increased risk of adverse pregnancy outcomes and patient friendly method of choice based on ease of performance, accuracy and efficiency.
This method provides a procedure for the determination of dissolved silicate concentration in estuarine and coastal waters. The dissolved silicate is mainly in the form of silicic acid, H SiO , in estuarine and 4 4 coastal waters. All soluble silicate, including colloidal silici...
ERIC Educational Resources Information Center
Myers, Alan
1990-01-01
A method of obtaining a crude mitochondrial extract from sheep and beef heart is described. The respiratory substrates succinate and malate are examined as well as the inhibitory effect of malonate. An interface with a microcomputer for plotting colorimeter results is discussed. (Author/CW)
Jittangprasert, Piyada; Wilairat, Prapin; Pootrakul, Pensri
2004-12-01
This paper describes a comparison of two analytical techniques, one employing bathophenanthrolinedisulfonate (BPT), a most commonly-used reagent for Fe (II) determination, as chromogen and an electrothermal atomic absorption spectroscopy (ETAAS) for the quantification of non-transferrin bound iron (NTBI) in sera from thalassemic patients. Nitrilotriacetic acid (NTA) was employed as the ligand for binding iron from low molecular weight iron complexes present in the serum but without removing iron from the transferrin protein. After ultrafiltration the Fe (III)-NTA complex was then quantified by both methods. Kinetic study of the rate of the Fe (II)-BPT complex formation for various excess amounts of NTA ligand was also carried out. The kinetic data show that a minimum time duration (> 60 minutes) is necessary for complete complex formation when large excess of NTA is used. Calibration curves given by colorimetric and ETAAS methods were linear over the range of 0.15-20 microM iron (III). The colorimetric and ETAAS methods exhibited detection limit (3sigma) of 0.13 and 0.14 microM, respectively. The NTBI concentrations from 55 thalassemic serum samples measured employing BPT as chromogen were statistically compared with the results determined by ETAAS. No significant disagreement at 95% confidence level was observed. It is, therefore, possible to select any one of these two techniques for determination of NTBI in serum samples of thalassemic patients. However, the colorimetric procedure requires a longer analysis time because of a slow rate of exchange of NTA ligand with BPT, leading to the slow rate of formation of the colored complex.
Chuang, Yen-Jun; Zhou, Xichun; Pan, Zhengwei; Turchi, Craig
2009-01-01
Carbohydrate functionalized nanoparticles, i.e., the glyconanoparticles, have wide application ranging from studies of carbohydrate-protein interactions, in vivo cell imaging, biolabeling, etc. Currently reported methods for preparation of glyconanoaprticles require multi-step modifications of carbohydrates moieties to conjugate to nanoparticle surface. However, the required synthetic manipulations are difficult and time consuming. We report herewith a simple and versatile method for preparing glyconanoparticles. This method is based on the utilization of clean and convenient microwave irradiation energy for one-step, site-specific conjugation of unmodified carbohydrates onto hydrazide-functionalized Au nanoparticles. A colorimetric assay that utilizes the ensemble of gold glyconanoparticles and Concanavalin A (ConA) was also presented. This feasible assay system was developed to analyze multivalent interactions and to determine the dissociation constant (Kd) for five kind of Au glyconanoparticles with lectin. Surface plasmon changes of the Au glyconanparticles as a function of lectin-carbohydrate interactions were measured and the dissociation constants were determined based on non-linear curve fitting. The strength of the interaction of carbohydrates with ConA was found to be as follows: Maltose > Mannose > Glucose > Lactose > MAN5. PMID:19698698
[A study of biomechanical method for urine test based on color difference estimation].
Wang, Chunhong; Zhou, Yue; Zhao, Hongxia; Zhou, Fengkun
2008-02-01
The biochemical analysis of urine is an important inspection and diagnosis method in hospitals. The conventional method of urine analysis covers mainly colorimetric visual appraisement and automation detection, in which the colorimetric visual appraisement technique has been superseded basically, and the automation detection method is adopted in hospital; moreover, the price of urine biochemical analyzer on market is around twenty thousand RMB yuan (Y), which is hard to enter into ordinary families. It is known that computer vision system is not subject to the physiological and psychological influence of person, its appraisement standard is objective and steady. Therefore, according to the color theory, we have established a computer vision system, which can carry through collection, management, display, and appraisement of color difference between the color of standard threshold value and the color of urine test paper after reaction with urine liquid, and then the level of an illness can be judged accurately. In this paper, we introduce the Urine Test Biochemical Analysis method, which is new and can be popularized in families. Experimental result shows that this test method is easy-to-use and cost-effective. It can realize the monitoring of a whole course and can find extensive applications.
Singh, Jaswant; Parkash, Jyoti; Kaur, Varinder; Singh, Raghubir
2017-10-05
A new method is reported for the quantification of some metallic components of healthcare products utilizing a Schiff base chelator derived from 2-hydroxyacetophenone and ethanolamine. The Schiff base chelator recognizes some metallic species such as iron, copper and zinc (important components of some healthcare products), and cadmium (common contaminant in healthcare products) giving colorimetric/fluorimetric response. It coordinates with Fe 2+ /Fe 3+ and Cu 2+ ions via ONO donor set and switches the colour to bright red, green and orange, respectively. Similarly, it switches 'ON' a fluorometric response when coordinates with Zn 2+ and Cd 2+ ions. In the present approach, detailed studies on the colorimetric and fluorimetric response of ONO Schiff base is investigated in detail. The Job plot for the complexation of ONO switch with various metal ions suggested formation of 1:1 (metal-chelator) complex with Fe 2+ , Fe 3+ , and Cu 2+ while 1:2 (metal-chelator) for Zn 2+ and Cd 2+ ions. The limit of detection, limit of quantification are 6.73, 18.0, 25.0, 0.65, 1.10μM and 27.0, 72.0, 100.0, 2.60 and 4.40μM for Fe 2+ , Fe 3+ , Cu 2+ , Zn 2+ and Cd 2+ ions, respectively. Under the optimized conditions, chelator was used for the quantification of important metals present in healthcare products via direct dissolution and furnace treatment during sample preparation. The results were found precise and accurate for both sample preparation techniques using the developed method. Copyright © 2017 Elsevier B.V. All rights reserved.
Mineral content of the honey produced in Zulia state, Venezuela.
Sulbarán de Ferrer, Betzabé; Ojeda de Rodríguez, Graciela; Peña, Jorge; Martínez, Janeth; Morán, María
2004-09-01
The mineral content of the honey produced in five zones of the Zulia state, Venezuela, during dry and rainy seasons was determined. The analyzed elements were: sodium, potassium (by emission spectroscopy), calcium, magnesium, copper, iron, manganese (by atomic absorption spectroscopy), phosphorus (phosphate ions, by colorimetric method), and ash content of raw honey samples directly collected from different beekeepers. The mean values for Na, K, Ca, Mg, Cu, Fe, Mn, and P were 353+84; 1774+138; 237+66; 52+24; 0.76+0.43; 13.5+10.23; 0.92+0.42 and 1642+323 mg/kg respectively. The mean ash content was 0.431+0.15%. Potassium was the most abundant of the elements determined. This results confirm that Zulian honey can be considered a good source of minerals.
Balsiger, Heather A.; de la Torre, Roberto; Lee, Wen-Yee; Cox, Marc B.
2010-01-01
The assay described here represents an improved yeast bioassay that provides a rapid yet sensitive screening method for EDCs with very little hands-on time and without the need for sample preparation. Traditional receptor-mediated reporter assays in yeast were performed twelve to twenty four hours after ligand addition, used colorimetric substrates, and, in many cases, required high, non-physiological concentrations of ligand. With the advent of new chemiluminescent substrates a ligand-induced signal can be detected within thirty minutes using high picomolar to low nanomolar concentrations of estrogen. As a result of the sensitivity (EC50 for estradiol is ~ 0.7 nM) and the very short assay time (2-4 hours) environmental water samples can typically be assayed directly without sterilization, extraction, and concentration. Thus, these assays represent rapid and sensitive approaches for determining the presence of contaminants in environmental samples. As proof of principle, we directly assayed wastewater influent and effluent taken from a wastewater treatment plant in the El Paso, TX area for the presence of estrogenic activity. The data obtained in the four-hour yeast bioassay directly correlated with GC-mass spectrometry analysis of these same water samples. PMID:20074779
Sensor Systems for Biological Agent Attacks: Protecting Buildings and Military Bases
2004-01-01
simple aerosol detectors, to those that identify an agent based on its genetic, structural, or chemical properties , to so- called "functional...Cytometry, 122 Target Binding That Changes Detectable Properties of Smart Sensor Surfaces, 124 Colorimetric Detection, 124 Fluorescence Detection, 125 One...microscopy. In addition to particles directly derived from living organisms, other particles in air may also share properties with the bioaerosols
Farnia, Parissa; Masjedi, Mohammad Reza; Mohammadi, Foroozan; Tabarsei, Payam; Farnia, Poopak; Mohammadzadeh, Ali Reza; Baghei, Parvaneh; Varahram, Mohammad; Hoffner, Sven; Velayati, Ali Akbar
2008-01-01
The malachite green microtube (MGMT) susceptibility assay was performed directly on sputum specimens (n = 80) and indirectly on Mycobacterium tuberculosis clinical isolates (n = 60). The technique is based on the malachite green dye, which changes color in response to M. tuberculosis growth. The MGMT assay is simple and rapid and does not require expensive instruments. PMID:18094133
Signal processing in an acousto-optical spectral colorimeter
NASA Astrophysics Data System (ADS)
Emeljanov, Sergey P.; Kludzin, Victor V.; Kochin, Leonid B.; Medvedev, Sergey V.; Polosin, Lev L.; Sokolov, Vladimir K.
2002-02-01
The algorithms of spectrometer signals processing in the acousto-optical spectral colorimeter, proposed earlier are discussed. This processing is directional on distortion elimination of an optical system spectral characteristics and photoelectric transformations, and also for calculation of tristimulus coefficients X,Y,Z in an international colorimetric system of a CIE - 31 and transformation them in coordinates of recommended CIE uniform contrast systems LUV and LAB.
Zero- and two-dimensional hybrid carbon phosphors for high colorimetric purity white light-emission.
Ding, Yamei; Chang, Qing; Xiu, Fei; Chen, Yingying; Liu, Zhengdong; Ban, Chaoyi; Cheng, Shuai; Liu, Juqing; Huang, Wei
2018-03-01
Carbon nanomaterials are promising phosphors for white light emission. A facile single-step synthesis method has been developed to prepare zero- and two-dimensional hybrid carbon phosphors for the first time. Zero-dimensional carbon dots (C-dots) emit bright blue luminescence under 365 nm UV light and two-dimensional nanoplates improve the dispersity and film forming ability of C-dots. As a proof-of-concept application, the as-prepared hybrid carbon phosphors emit bright white luminescence in the solid state, and the phosphor-coated blue LEDs exhibit high colorimetric purity white light-emission with a color coordinate of (0.3308, 0.3312), potentially enabling the successful application of white emitting phosphors in the LED field.
Colorimetric assay for urinary track infection disease diagnostic on flexible substrate
NASA Astrophysics Data System (ADS)
Safavieh, Mohammadali; Ahmed, Minhaz Uddin; Zourob, Mohammed
2012-10-01
We are presenting cassette as a novel point of care diagnostic device. This device is easy to use, low cost to prepare, high throughput and can analyze several samples at the same time. We first, demonstrate the preparation method of the device. Then, fabrication of the flexible substrate has been presented. The device has been used for detection of the real sample of E.coli bacteria following by colorimetric detection. We have shown that we could detect 30 cfu/ml bacteria and 100 fg/μl of Staphylococous aureus DNA in 1 hr using LAMP amplification technique. This device will be helpful in hospitals and doctor's office for analysis of several patients' samples at the same time.
Li, WanYun; Lu, ShiYu; Bao, ShuJuan; Shi, ZhuanZhuan; Lu, Zhisong; Li, ChangMing; Yu, Ling
2018-01-15
A visual colorimetric microfluidic paper-based analytical device (μPAD) was constructed following the direct synthesis of enzyme-inorganic hybrid nanomaterials on the paper matrix. An inorganic solution of MnSO 4 and KH 2 PO 4 containing a diluted enzyme (glucose oxidase, GOx) was subsequently pipetted onto cellulose paper for the in situ growth of GOx@Mn 3 (PO 4 ) 2 hybrid functional materials. The characterization of the morphology and chemical composition validated the presence of hybrid materials roots in the paper fiber, while the Mn 3 (PO 4 ) 2 of the hybrid provided both a surface for enzyme anchoring and a higher peroxidase-like catalytic activity as compared to the Mn 3 (PO 4 ) 2 crystal that was synthesized without enzyme modulation. This new approach for the in situ growth of an enzyme-inorganic hybrid on a paper matrix eliminates centrifugation and the dry process by casting the solution on paper. The sensing material loading was highly reproducible because of the accuracy and stability of pipetting, which eventually contributed to the reliability of the μPAD. The self-assembled natural and artificial enzyme hybrid on the μPADs specifically detected glucose from a group of interferences, which shows great specificity using this method. Moreover, the colorimetric signal exhibited detection limitation for glucose is 0.01mM, which lies in the physiological range of glucose in biological samples. Copyright © 2017 Elsevier B.V. All rights reserved.
L-arginine modified magnetic nanoparticles: green synthesis and characterization
NASA Astrophysics Data System (ADS)
Bagherpour, A. R.; Kashanian, F.; Seyyed Ebrahimi, S. A.; Habibi-Rezaei, M.
2018-02-01
In recent years, there has been considerable interest in Arg which is a unique, nontoxic, and biocompatible biomolecule since it can be utilized as an agent for the functionalization and subsequent stabilization of MNPs against oxidation and aggregation, during or after a synthesis procedure. Our studies demonstrate that Arg has great impacts on MNPs with the decreasing size of the particle. Also, saturation magnetization and electrostatic interactions of RMNPs have a direct impact on biological molecules such as proteins and nucleic acids. By controlling the concentration of Arg, it is possible to accurately control the above-mentioned characteristics, which are useful tools for applications such as connecting to antibodies, catalysis, drug loading, and modification of MNP stability. In the current study, three RMNPs with different Arg densities, i.e. 0.42, 1.62, and 2.29 μg per mg were successfully synthesized through a simple co-precipitation method (named p 0.5, p 1, and p 1.5, respectively) and verified by colorimetric determination. Also, the as-synthesized RMNP powders were characterized by XRD, SEM/EDAX, FTIR, VSM, and zeta potential analysis. The presence of a magnetic core was proved by XRD, FTIR, and EDAX. Colorimetric analysis showed the existence of Arg in the synthesized samples. According to the zeta potential and VSM results, increasing the cap of Arg on the MNP surface leads to an increase in the surface charge and decrease in the magnetization of the RMNPs, respectively.
Francisco, Fabiane Lacerda; Saviano, Alessandro Morais; Pinto, Terezinha de Jesus Andreoli; Lourenço, Felipe Rebello
2014-08-01
Microbiological assays have been used to evaluate antimicrobial activity since the discovery of the first antibiotics. Despite their limitations, microbiological assays are widely employed to determine antibiotic potency of pharmaceutical dosage forms, since they provide a measure of biological activity. The aim of this work is to develop, optimize and validate a rapid colorimetric microplate bioassay for the potency of neomycin in pharmaceutical drug products. Factorial and response surface methodologies were used in the development and optimization of the choice of microorganism, culture medium composition, amount of inoculum, triphenyltetrazolium chloride (TTC) concentration and neomycin concentration. The optimized bioassay method was validated by the assessment of linearity (range 3.0 to 5.0μg/mL, r=0.998 and 0.994 for standard and sample curves, respectively), precision (relative standard deviation (RSD) of 2.8% and 4.0 for repeatability and intermediate precision, respectively), accuracy (mean recovery=100.2%) and robustness. Statistical analysis showed equivalency between agar diffusion microbiological assay and rapid colorimetric microplate bioassay. In addition, microplate bioassay had advantages concerning the sensitivity of response, time of incubation, and amount of culture medium and solutions required. Copyright © 2014 Elsevier B.V. All rights reserved.
Kim, Manuela; Stripeikis, Jorge; Iñón, Fernando; Tudino, Mabel
2007-05-15
A simple and sensitive HPLC post-derivatization method with colorimetric detection has been developed for the determination of N-nitroso glyphosate in samples of technical glyphosate. Separation of the analyte was accomplished using an anionic exchange resin (2.50mmx4.00mm i.d., 15mum particle size, functional group: quaternary ammonium salt) with Na(2)SO(4) 0.0075M (pH 11.5) (flow rate: 1.0mLmin(-1)) as mobile phase. After separation, the eluate was derivatized with a colorimetric reagent containing sulfanilamide 0.3% (w/v), [N-(1-naphtil)ethilendiamine] 0.03% (w/v) and HCl 4.5M in a thermostatized bath at 95 degrees C. Detection was performed at 546nm. All stages of the analytical procedure were optimized taking into account the concept of analytical minimalism: less operation times and costs; lower sample, reagents and energy consumption and minimal waste. The limit of detection (k=3) calculated for 10 blank replicates was 0.04mgL(-1) (0.8mgkg(-1)) in the solid sample which is lower than the maximum tolerable accepted by the Food and Agriculture Organization of the United Nations.
Biothiols induced colour change of silver nanoparticles: A colorimetric sensing strategy
NASA Astrophysics Data System (ADS)
Thomas, Ambily; Sivasankaran, Unni; Kumar, Krishnapillai Girish
2018-01-01
A sensor for the detection and determination of bio-thiols (glutathione (GSH) and cysteamine (Cyste)) has been developed by integrating the distinguished distance related optical characteristics of silver nanoparticles with the simplicity of colorimetric technique. In presence of these analytes, shift in surface plasmon resonance (SPR) absorption of silver nanoparticles (AgNPs) with change in its colour was observed. Yellow coloured AgNPs solution becomes colourless in presence of GSH and changes to red in presence of Cyste. FTIR, TEM and DLS studies were used to confirm the mechanism. The difference in absorption of AgNPs in the absence and presence of GSH was found to vary linearly in the range 1.00 × 10- 5 M to 5.00 × 10- 7 M concentration range with limit of detection at 3.68 × 10- 7 M. The method can also be applied to quantify Cyste in the range 1.10 × 10- 6 M to 5.00 × 10- 8 M with limit of detection at 1.80 × 10- 8 M. The utility of the proposed colorimetric assay is validated by determination of GSH and Cyste in artificial blood serum.
Alexiades-Armenakas, Macrene R; Bernstein, Leonard J; Friedman, Paul M; Geronemus, Roy G
2004-08-01
To assess the safety and efficacy of the 308-nm excimer laser in pigment correction of hypopigmented scars and striae alba. Institutional review board-approved randomized controlled trial. Private research center. Volunteer sample of 31 adult subjects with hypopigmented scars or striae alba distributed on the face, torso, or extremities. Lesions were randomized to receive treatment or not, with site-matched normal control areas. Treatments were initiated with a minimal erythema dose minus 50 mJ/cm(2) to affected areas. Subsequent treatments were performed biweekly until 50% to 75% pigment correction, then every 2 weeks thereafter until a maximum of 10 treatments, 75% increase in colorimetric measurements, or 100% visual pigment correction. Pigment correction by visual and colorimetric assessments compared with untreated control lesions and site-matched normal skin before each treatment and at 1-, 2-, 4-, and 6-month follow-up intervals. Occurrence of erythema, blistering, dyspigmentation, or other adverse effects was monitored. The percentage pigment correction by both assessments increased in direct proportion to the number of treatments. The mean percentage pigment correction by visual assessment relative to control of 61% (95% confidence interval [CI], 55%-67%) for scars and 68% (95% CI, 62%-74%) for striae was achieved after 9 treatments. The mean percentage pigmentation by colorimetric measurements relative to control of 101% (95% CI, 99%-103%) for scars and 102% (95% CI, 99%-104%) for striae was achieved after 9 treatments. Both sets of values gradually declined toward baseline levels during the 6-month follow-up. No blistering or dyspigmentation occurred. Therapy with the 308-nm excimer laser is safe and effective in pigment correction of hypopigmented scars and striae alba. Mean final pigment correction rates relative to control sites of approximately 60% to 70% by visual assessment and 100% by colorimetric analysis were observed after 9 treatments administered biweekly. Maintenance treatment every 1 to 4 months is required to sustain the cosmetic benefit.
76 FR 37796 - Notice of Availability of Government-Owned Inventions; Available for Licensing
Federal Register 2010, 2011, 2012, 2013, 2014
2011-06-28
... Aircraft Division, Business and Partnership Office, Office of Research and Technology Applications... October 26, 2010 U.S. Patent Application No. 7,839,304 B2: Method and System for Alerting Aircrew to... Application No. 12/868,772: Colorimetric Method for Detection of Biodiesel in Fuel, Navy Case No. PAX37, filed...
Dawson, V.K.; Meinertz, J.R.; Schmidt, L.J.; Gingerich, W.H.
2003-01-01
Concentrations of chloramine-T must be monitored during experimental treatments of fish when studying the effectiveness of the drug for controlling bacterial gill disease. A surrogate analytical method for analysis of chloramine-T to replace the existing high-performance liquid chromatography (HPLC) method is described. A surrogate method was needed because the existing HPLC method is expensive, requires a specialist to use, and is not generally available at fish hatcheries. Criteria for selection of a replacement method included ease of use, analysis time, cost, safety, sensitivity, accuracy, and precision. The most promising approach was to use the determination of chlorine concentrations as an indicator of chloramine-T. Of the currently available methods for analysis of chlorine, the DPD (N,N-diethyl-p-phenylenediamine) colorimetric method best fit the established criteria. The surrogate method was evaluated under a variety of water quality conditions. Regression analysis of all DPD colorimetric analyses with the HPLC values produced a linear model (Y=0.9602 X+0.1259) with an r2 value of 0.9960. The average accuracy (percent recovery) of the DPD method relative to the HPLC method for the combined set of water quality data was 101.5%. The surrogate method was also evaluated with chloramine-T solutions that contained various concentrations of fish feed or selected densities of rainbow trout. When samples were analyzed within 2 h, the results of the surrogate method were consistent with those of the HPLC method. When samples with high concentrations of organic material were allowed to age more than 2 h before being analyzed, the DPD method seemed to be susceptible to interference, possibly from the development of other chloramine compounds. However, even after aging samples 6 h, the accuracy of the surrogate DPD method relative to the HPLC method was within the range of 80-120%. Based on the data comparing the two methods, the U.S. Food and Drug Administration has concluded that the DPD colorimetric method is appropriate to use to measure chloramine-T in water during pivotal efficacy trials designed to support the approval of chloramine-T for use in fish culture. ?? 2003 Elsevier Science B.V. All rights reserved.
Color-rendering indices in global illumination methods
NASA Astrophysics Data System (ADS)
Geisler-Moroder, David; Dür, Arne
2009-10-01
Human perception of material colors depends heavily on the nature of the light sources that are used for illumination. One and the same object can cause highly different color impressions when lit by a vapor lamp or by daylight, respectively. On the basis of state-of-the-art colorimetric methods, we present a modern approach for the calculation of color-rendering indices (CRI), which were defined by the International Commission on Illumination (CIE) to characterize color reproduction properties of illuminants. We update the standard CIE method in three main points: first, we use the CIELAB color space; second, we apply a linearized Bradford transformation for chromatic adaptation; and finally, we evaluate color differences using the CIEDE2000 total color difference formula. Moreover, within a real-world scene, light incident on a measurement surface is composed of a direct and an indirect part. Neumann and Schanda [Proc. CGIV'06 Conf., Leeds, UK, pp. 283-286 (2006)] have shown for the cube model that diffuse interreflections can influence the CRI of a light source. We analyze how color-rendering indices vary in a real-world scene with mixed direct and indirect illumination and recommend the usage of a spectral rendering engine instead of an RGB-based renderer for reasons of accuracy of CRI calculations.
Sharma, Rekha; Dhillon, Ankita; Kumar, Dinesh
2018-03-26
The present paper reports a facile and selective colorimetric method for the detection of potential environmental and health hazardous metal ions using green synthesized silver nanoparticles (AgNPs). Here the organic functional groups present in the plant extract (Mentha arvensis) are used as reductants and stabilizers in the synthesis of AgNPs. They also provide a suitable binding site to the (Al(III)) analyte in the detection mechanism. The leaf extract of Mentha arvensis was used to synthesize AgNPs at room-temperature and at 80 °C. The AgNPs synthesized at 80 °C exhibit excellent selective colorimetric detection of Al(III). The as-synthesized AgNPs have been characterized, and the synthesis, stabilization of NPs and detection mechanism has also been illustrated by using UV-vis, XPS, FTIR, TEM, EDX, SEM, AAS, and TGA analytical tools and techniques. The selectivity of detection probe was supported by the reaction between probe and metal ions followed first-order kinetics having the highest value of the regression coefficient (R 2 = 0.99) for Al(III) and the analysis of thermodynamic parameters. The prepared sensor showed a lower limit of detection (LOD) of 1 nM (S/N = 3.2) in real water samples. The proposed method can be successfully utilized for the detection of Al(III) from both drinking and real water samples at the nanomolar level.
Deng, Jingjing; Ma, Wenjie; Yu, Ping; Mao, Lanqun
2015-07-07
This study demonstrates a new strategy for colorimetric and fluorescent dual mode sensing of alcoholic strength (AS) in spirit samples based on stimuli-responsive infinite coordination polymers (ICPs). The ICP supramolecular network is prepared with 1,4-bis(imidazol-1-ylmethyl)benzene (bix) as the ligand and Zn(2+) as the central metal ion in ethanol, in which rhodamine B (RhB) is encapsulated through self-adaptive chemistry. In pure ethanol solvent, the as-formed RhB/Zn(bix) is well dispersed and quite stable. However, the addition of water into the ethanol dispersion of RhB/Zn(bix) destroys Zn(bix) network structure, resulting in the release of RhB from ICP into the solvent. As a consequence, the solvent displays the color of released RhB and, at the meantime, turns on the fluorescence of RhB, which constitutes a new mechanism for colorimetric and fluorescent dual mode sensing of AS in commercial spirit samples. With the method developed here, we could distinguish the AS of different commercial spirit samples by the naked eye within a wide linear range from 20 to 100% vol and by monitoring the increase of fluorescent intensity of the released RhB. This study not only offers a new method for on-spot visible detection of AS in commercial spirit samples, but also provides a strategy for designing dual mode sensing mechanisms for different analytical purposes based on novel stimuli-responsive materials.
Xia, Ning; Liu, Ke; Zhou, Yingying; Li, Yuanyuan; Yi, Xinyao
2017-01-01
miRNAs have emerged as new biomarkers for the detection of a wide variety of cancers. By employing duplex-specific nuclease for signal amplification and gold nanoparticles (AuNPs) as the carriers of detection probes, a novel electrochemical assay of miRNAs was performed. The method is based on conversion of the well-known colorimetric assay into electrochemical analysis with enhanced sensitivity. DNA capture probes immobilized on the electrode surface and ferrocene (Fc)-labeled DNA detection probes (denoted “Fc-DNA-Fc”) presented in the solution induced the assembly of positively charged AuNPs on the electrode surface through the electrostatic interaction. As a result, a large number of Fc-DNA-Fc molecules were attached on the electrode surface, thus amplifying the electrochemical signal. When duplex-specific nuclease was added to recycle the process of miRNA-initiated digestion of the immobilized DNA probes, Fc-DNA-Fc-induced assembly of AuNPs on the electrode surface could not occur. This resulted in a significant fall in the oxidation current of Fc. The current was found to be inversely proportional to the concentration of miRNAs in the range of 0–25 fM, and a detection limit of 0.1 fM was achieved. Moreover, this work presents a new method for converting colorimetric assays into sensitive electrochemical analyses, and thus would be valuable for design of novel chemical/biosensors. PMID:28761341
Suebsing, R; Kampeera, J; Tookdee, B; Withyachumnarnkul, B; Turner, W; Kiatpathomchai, W
2013-10-01
Streptococcus agalactiae and Strep. iniae are bacterial pathogens that cause streptococcosis in many fish species. An accelerated colorimetric loop-mediated isothermal amplification (LAMP) assay with pre-addition of calcein was established, and the transmission and detection of Strep. agalactiae and Strep. iniae in tilapia under natural aquatic environment were investigated. A positive reaction was observed by a colour change from orange to green through the naked eyes after completion at 63°C for 30 min with 10 times higher sensitivity than that of nested PCR assays and without cross-amplification with other fish bacterial pathogens. All sample types of Nile and red tilapia (broodstock, fertilized egg, fry) were Strep. agalactiae- and Strep. iniae positive by this new method, implying that they could be vertically transmitted. With its application for screening broodstock and fry before stocking and for monitoring fish health in grow-out ponds, the method would become very useful in fish farming industry. The application of colorimetric LAMP with pre-addition of calcein offers simple, rapid and sensitive technique with applicability for small field laboratories. This technique explored the possible vertical transmission mode of Strep. agalactiae and Strep. iniae under natural aquatic environment. It could be such preliminary data provided for the screening broodstock before breeding and/or the specific-pathogen-free production. © 2013 The Society for Applied Microbiology.
NASA Astrophysics Data System (ADS)
Leng, Yumin; He, Junbao; Li, Bo; Xing, Xiaojing; Guo, Yongming; Ye, Liqun; Lu, Zhiwen
2017-09-01
The different sized and shaped Au NPs have intrigued considerable attention, because they possess different surface plasma resonance (SPR) absorption bands and thus result in many colorimetric Au NP-based detection applications. In this article, four different sized and shaped Au NPs of nanodots/rods were prepared and characterized. The as-prepared Au NPs were modified by the negatively charged anions of [SCH2CO2]2- to investigate both the size and shape effects of modified Au NPs on colorimetric detection of Co2+ and the corresponding SPR absorption properties. The different-shaped Au NPs possess different SPR absorption properties. The Au nanorods appeared to be colorimetric sensitive for Co2+ sensing.
Amini, Bahram; Kamali, Mehdi; Salouti, Mojtaba; Yaghmaei, Parichehreh
2018-06-15
Colorimetric DNA detection is preferred over other methods for clinical molecular diagnosis because it does not require expensive equipment. In the present study, the colorimetric method based on gold nanoparticles (GNPs) and endonuclease enzyme was used for the detection of P. aeruginosa ETA gene. Firstly, the primers and probe for P. aeruginosa exotoxin A (ETA) gene were designed and checked for specificity by the PCR method. Then, GNPs were synthesized using the citrate reduction method and conjugated with the prepared probe to develop the new nano-biosensor. Next, the extracted target DNA of the bacteria was added to GNP-probe complex to check its efficacy for P. aeruginosa ETA gene diagnosis. A decrease in absorbance was seen when GNP-probe-target DNA cleaved into the small fragments of BamHI endonuclease due to the weakened electrostatic interaction between GNPs and the shortened DNA. The right shift of the absorbance peak from 530 to 562nm occurred after adding the endonuclease. It was measured using a UV-VIS absorption spectroscopy that indicates the existence of the P. aeruginosa ETA gene. Sensitivity was determined in the presence of different concentrations of target DNA of P. aeruginosa. The results obtained from the optimized conditions showed that the absorbance value has linear correlation with concentration of target DNA (R: 0.9850) in the range of 10-50ngmL -1 with the limit detection of 9.899ngmL -1 . Thus, the specificity of the new method for detection of P. aeruginosa was established in comparison with other bacteria. Additionally, the designed assay was quantitatively applied to detect the P. aeruginosa ETA gene from 10 3 to 10 8 CFUmL -1 in real samples with a detection limit of 320CFUmL -1 . Copyright © 2018 Elsevier B.V. All rights reserved.
Li, Dan; Duan, Huazhen; Ma, Yadan; Deng, Wei
2018-05-01
This study demonstrates a novel strategy for colorimetric/surface-enhanced Raman scattering (SERS) dual-mode sensing of sulfur dioxide (SO 2 ) by coupling headspace sampling (HS) with paper-based analytical device (PAD). The smart and multifunctional PAD is fabricated with a vacuum filtration method in which 4-mercaptopyridine (Mpy)-modified gold nanorods (GNRs)-reduced graphene oxide (rGO) hybrids (rGO/MPy-GNRs), anhydrous methanol, and starch-iodine complex are immobilized into cellulose-based filter papers. The resultant PAD exhibits a deep-blue color with a strong absorption peak at 600 nm due to the formation of an intermolecular charge-transfer complex between starch and iodine. However, the addition of SO 2 induces the Karl Fischer reaction, resulting in the decrease of color and increase of SERS signals. Therefore, the PAD can be used not only as a naked-eye indicator of SO 2 changed from blue to colorless but also as a highly sensitive SERS substrates because of the SO 2 -triggered conversion of Mpy to pyridine methyl sulfate on the GNRs. A distinguishable change in the color was observed at a SO 2 concentration of 5 μM by the naked eye, and a detection limit as low as 1.45 μM was obtained by virtue of UV-vis spectroscopy. The PAD-based SERS method is effective over a wide range of concentrations (1 μM to 2000 μM) for SO 2 , and the detection limit for SO 2 is found to be 1 μM. The HS-PAD based colorimetric/SERS method is applied for the determination of SO 2 in wine, and the detection results match well with those obtained from the traditional Monier-Williams method. This study not only offers a new method for on-site monitoring of SO 2 but also provides a new strategy for designing of paper-based sensing platform for a wide range of field-test applications.
Kwon, Jae-Sung; Kim, Kwang-Mahn; Kim, Kyoung-Nam
2014-10-01
The biocompatibility evaluation of nanomaterials is essential for their medical diagnostic and therapeutic usage, where a cytotoxicity test is the simplest form of biocompatibility evaluation. Three methods have been commonly used in previous studies for the cytotoxicity testing of nanomaterials: trypan blue exclusion, colorimetric assay using water soluble tetrazolium (WST), and imaging under a microscope following calcein AM/ethidium homodimer-1 staining. However, there has yet to be a study to compare each method. Therefore, in this study three methods were compared using the standard reference material of sodium lauryl sulfate (SLS). Each method of the cytotoxicity test was carried out using mouse fibroblasts of L-929 exposed to different concentrations of SLS. Compared to the gold standard trypan blue exclusion test, both colorimetric assay using water soluble tetrazolium (WST) and imaging under microscope with calcein AM/ethidium homodimer-1 staining showed results that were not statistically different. Also, each method exhibited various advantages and disadvantages, which included the need of equipment, time taken for the experiment, and provision of additional information such as cell morphology. Therefore, this study concludes that all three methods of cytotoxicity testing may be valid, though careful consideration will be needed when selecting tests with regard to time, finances, and the amount of information required by the researcher(s).
Suebsing, Rungkarn; Kampeera, Jantana; Sirithammajak, Sarawut; Withyachumnarnkul, Boonsirm; Turner, Warren; Kiatpathomchai, Wansika
2015-03-01
Flavobacterium columnare, the causative agent of columnaris disease in fish, affects many economically important freshwater fish species. A colorimetric method of loop-mediated isothermal amplification with the pre-addition of calcein (LAMP-calcein) was developed and used to detect the presence of F. columnare in farmed tilapia (Nile Tilapia Oreochromis niloticus and red tilapia [Nile Tilapia × Mozambique Tilapia O. mossambicus]) and rearing water. The detection method, based on a change in color from orange to green, could be performed within 45 min at 63°C. The method was highly specific, as it had no cross-detections with 14 other bacterial species, including other fish pathogens and two Flavobacterium species. The method has a minimum detection limit of 2.2 × 10(2) F. columnare CFU; thus, it is about 10 times more sensitive than conventional PCR. With this method, F. columnare was detected in gonad, gill, and blood samples from apparently healthy tilapia broodstock as well as in samples of fertilized eggs, newly hatched fry, and rearing water. The bacteria isolated from the blood were further characterized biochemically and found to be phenotypically identical to F. columnare. The amplified products from the LAMP-calcein method had 97% homology with the DNA sequence of F. columnare.
Hernández-Andrés, J; Romero, J; Lee, R L
2001-02-01
As part of our ongoing research into the clear daytime sky's visible structure, we analyze over 1,500 skylight spectra measured during a seven-month period in Granada, Spain. We use spectral radiances measured within 3 degrees fields of view (FOV's) to define colorimetric characteristics along four sky meridians: the solar meridian and three meridians at azimuths of 45 degrees, 90 degrees, and 315 degrees relative to it. The resulting clear-sky chromaticities in 44 different view directions (1) are close to but do not coincide with the CIE daylight locus, (2) form V-shaped meridional chromaticity curves along it (as expected from theory), and (3) have correlated color temperatures (CCT's) ranging from 3,800 K to infinity K. We also routinely observe that sky color and luminance are asymmetric about the solar meridian, usually perceptibly so. A principal-components analysis shows that three vectors are required for accurate clear-sky colorimetry, whereas six are needed for spectral analyses.
Huo, Yuan; Qi, Liang; Lv, Xiao-Jun; Lai, Ting; Zhang, Jing; Zhang, Zhi-Qi
2016-04-15
Adenosine triphosphate (ATP) is the most direct source of energy in organisms. This study is the first to demonstrate that ATP-aptamer complexes provide greater protection for unmodified gold nanoparticles (AuNPs) against salt-induced aggregation than either aptamer or ATP alone. This protective effect was confirmed using transmission electron microscopy, dynamic light scattering, Zeta potential measurement, and fluorescence polarization techniques. Utilizing controlled particle aggregation/dispersion as a gauge, a sensitive and selective aptasensor for colorimetric detection of ATP was developed using ATP-binding aptamers as the identification element and unmodified AuNPs as the probe. This aptasensor exhibited a good linear relationship between the absorbance and the logarithm concentration of ATP within a 50-1000 nM range. ATP analogs such as guanosine triphosphate, uridine triphosphate and cytidine triphosphate resulted in little or no interference in the determination of ATP. Copyright © 2015 Elsevier B.V. All rights reserved.
Fu, Xiuli; Chen, Lingxin; Li, Jinhua
2012-08-21
A novel colorimetric method was developed for ultrasensitive detection of heparin based on self-assembly of gold nanoparticles (AuNPs) onto the surface of graphene oxide (GO). Polycationic protamine was used as a medium for inducing the self-assembly of citrate-capped AuNPs on GO through electrostatic interaction, resulting in a shift in the surface plasmon resonance (SPR) absorption of AuNPs and exhibiting a blue color. Addition of polyanionic heparin disturbed the self-assemble of AuNPs due to its strong affinity to protamine. With the increase of heparin concentration, the amounts of self-assembly AuNPs decreased and the color changed from blue to red in solution. Therefore, a "blue-to-red" colorimetric sensing strategy based on self-assembly of AuNPs could be established for heparin detection. Compared with the commonly reported aggregation-based methods ("red-to-blue"), the color change from blue to red was more eye-sensitive, especially in low concentration of target. Moreover, stronger interaction between protamine and heparin led to distinguish heparin from its analogues as well as various potentially coexistent physiological species. The strategy was simply achieved by the self-assembly nature of AuNPs and the application of two types of polyionic media, showing it to be label-free, simple, rapid and visual. This method could selectively detect heparin with a detection limit of 3.0 ng mL(-1) in standard aqueous solution and good linearity was obtained over the range 0.06-0.36 μg mL(-1) (R = 0.9936). It was successfully applied to determination of heparin in fetal bovine serum samples as low as 1.7 ng mL(-1) with a linear range of 0-0.8 μg mL(-1).
Hill, April A; Lipert, Robert J; Porter, Marc D
2010-03-15
The increase in bacterial resistance to antibiotics has led to resurgence in the use of silver as a biocidal agent in applications ranging from washing machine additives to the drinking water treatment system on the International Space Station (ISS). However, growing concerns about the possible toxicity of colloidal silver to bacteria, aquatic organisms and humans have led to recently issued regulations by the US EPA and FDA regarding the usage of silver. As part of an ongoing project, we have developed a rapid, simple method for determining total silver, both ionic (silver(I)) and colloidal, in 0.1-1mg/L aqueous samples, which spans the ISS potable water target of 0.3-0.5mg/L (total silver) and meets the US EPA limit of 0.1mg/L in drinking water. The method is based on colorimetric solid-phase extraction (C-SPE) and involves the extraction of silver(I) from water samples by passage through a solid-phase membrane impregnated with the colorimetric reagent DMABR (5-[4-(dimethylamino)benzylidene]rhodanine). Silver(I) exhaustively reacts with impregnated DMABR to form a colored compound, which is quantified using a handheld diffuse reflectance spectrophotometer. Total silver is determined by first passing the sample through a cartridge containing Oxone, which exhaustively oxidizes colloidal silver to dissolved silver(I). The method, which takes less than 2 min to complete and requires only approximately 1 mL of sample, has been validated through a series of tests, including a comparison with the ICP-MS analysis of a water sample from ISS that contained both silver(I) and colloidal silver. Potential earth-bound applications are also briefly discussed. Copyright (c) 2009 Elsevier B.V. All rights reserved.
Zhang, Haijuan; Qi, Shengda; Dong, Yalei; Chen, Xiaojiao; Xu, Yinyin; Ma, Yanhua; Chen, Xingguo
2014-05-15
This paper describes a colorimetric approach to determine trace amounts of nitrite in water supplies, meat and dairy products using 1-butyl-3-methylimidazolium-modified methyl red ([BMIM]MR) as a colour reagent. The technique capitalises on the catalytic effect of nitrite on the oxidative degradation of [BMIM]MR by potassium bromate in acidic media. The absorbances were proportional to nitrite concentrations in the range of 8.70×10(-2) to 4.17 μM with a detection limit of 1.64×10(-2) μM. Compared with the method using methyl red as a colour reagent, 60 times improvement of sensitivity was obtained. Activation energy and the apparent rate constant for the catalytic reaction are 61.11 kJ mol(-1) and 1.18×10(4) s(-1), respectively. The proposed method was successfully applied for the analysis of nitrite in Yellow River water, chicken, and milk with recoveries ranging from 96% to 105%. Copyright © 2013 Elsevier Ltd. All rights reserved.
Üzer, Ayşem; Yalçın, Uğur; Can, Ziya; Erçağ, Erol; Apak, Reşat
2017-12-01
Pentaerythritol tetranitrate (PETN) is the nitrate ester of pentaerythritol, used as an energetic and filling material for military and civilian purposes and rarely for terrorist actions. As there is no reliable nano-colorimetric method for PETN assay, we developed an indirect method based on the determination of nitrite, obtained by reduction of nitrate derived from the alkaline hydrolysis of PETN with H 2 O 2 . We colorimetrically determined the final product, nitrite, by both conventional Griess reaction and a recently developed gold nanoparticle-4-aminothiophenol-N-(1-naphthyl)-ethylenediamine (AuNP-4-ATP+NED) method. Nitramines (RDX and HMX), if present, could be degraded by alkaline hydrolysis, without affecting PETN. The analytical performance characteristics of the developed assays as molar absorptivity (ε), limits of detection (LOD) and quantification (LOQ) were: ɛ=1.06×10 5 L mol -1 cm -1 , LOD=0.03mgL -1 and LOQ=0.11mgL -1 for indirect Griess method; ɛ=1.9×10 4 Lmol -1 cm -1 ; LOD=0.12mgL -1 and LOQ=0.4mgL -1 for AuNP-4-ATP+NED method. Both methods were applied to a 1:1 (w/w) mixture of PETN and TNT (corresponding to the composition of military explosive 'Pentolite'). In order to eliminate the interference from TNT, the Meisenheimer anion of TNT formed in alkaline medium was retained on a strongly basic anion exchange resin column. As PETN had a very low solubility in water, common soil ions could be eliminated by prewashing the sample with water, or in acetone-water mixtures, Ca 2+ , K + , Cl - , SO 4 2- , and NO 3 - could be tolerated at equal (1:1) mass ratios. Soil nitrates and nitrites, at a mass ratio of 50:1, could be separated from PETN with the aid of their insolubilities in acetone and of their retention affinity toward a strongly basic anion-exchange resin. The developed method was statistically validated against a reference GC-MS method. Copyright © 2017 Elsevier B.V. All rights reserved.
Hayden, S R; Sciammarella, J; Viccellio, P; Thode, H; Delagi, R
1995-06-01
To evaluate the ability of a disposable, colorimetric end-tidal CO2 detector to verify proper endotracheal (ET) tube placement in out-of-hospital cardiac arrest, and to correlate semiquantitative CO2 measurements with the rate of return of spontaneous circulation (ROSC). Prospective, observational study using a convenience sample of intubated out-of-hospital cardiac arrest patients. A disposable, colorimetric end-tidal CO2 detector was attached to the ET tube after intubation. In the absence of a colorimetric change, the paramedics reassessed the tube placement and could reintubate the patient. Tube placement was verified at the hospital. Paramedics were instructed to contact the base station and report the colorimetric change upon hospital arrival. ROSC was defined as restoration of a self-sustaining pulse until hospital arrival. Between December 1990 and May 1993, ET tubes were placed in 566 victims of out-of-hospital cardiac arrest. 541 of the 566 intubations (95.6%) were associated with a color change. In one case with a color change and out-of-hospital clinical evidence of proper tube placement, the tube was determined to be in the esophagus at the hospital. Correct placement of the remaining 565 of 566 (99.8%) tubes was verified. Of the 566 patients who had a colorimetric change, 91 (16%) had ROSC vs one of 25 (4%) patients who did not have a color change. In one subgroup (n = 179), the degree of color change was highly associated with ROSC (p = 0.004). A disposable, colorimetric end-tidal CO2 detector appears reliable in verifying proper ET tube placement in victims of out-of-hospital cardiac arrest. The degree of color change correlates with the probability of ROSC.
A SIMPLE COLORIMETRIC METHOD TO DETECT BIOLOGICAL EVIDENCE OF HUMAN EXPOSURE TO MICROCYSTINS
Toxic cyanobacteria are contaminants of surface waters worldwide. Microcystins are some of the most commonly detected toxins. Biological evidence of human exposure may be difficult to obtain due to limitations associated with cost, laboratory capacity, analytic support, and exp...
Gold nanoparticles mediated colorimetric assay for HIV-Tat protein detection
NASA Astrophysics Data System (ADS)
Hashwan, Saeed S. Ba; Ruslinda, A. Rahim; Fatin, M. F.; Gopinath, Subash C. B.; Thivina, V.; Tony, V. C. S.; Arshad, M. K. Md.; Hashim, U.
2016-07-01
Gold-nanoparticle (AuNP) based colorimetric assays have been formulated for different biomolecular interactions. With this assay the probe such as antibody immobilized on the Au surface and in the presence of appropriate binding partner (antigen), will interact with each other on the Au surface. By following this strategy, herein we formulated a detection system with two anti-HIV-Tat antibodies, Mono (McAb) - and polyclonal (PcAb) by immobilizing them independently with different AuNPs. Under this condition, these two antibodies are under dispersed condition, and in the presence of HIV-Tat antigen, these molecules will be connected and forms the aggregation of AuNPs. This strategy yield rapid results, can be monitored by the spectral changes in UV-Vis spectrophotometry. Experiments were performed with two different methods using two anti-HIV-Tats monoclonal and one Polyclonal antibody against the antigen HIV-Tat. Between these methods conjugation of HIV-Tat and McAb on the AuNP followed by addition of PcAb yielded better results.
Parihar, Sanjay; Boricha, Vinod P; Jadeja, R N
2015-03-01
Two novel Rhodamine-pyrazolone-based colorimetric off-on fluorescent chemosensors for Fe(3+) ions were designed and synthesized using pyrazolone as the recognition moiety and Rhodamine 6G as the signalling moiety. The photophysical properties and Fe(3+) -binding properties of sensors L(1) and L(2) in acetonitrile-aqueous solution were also investigated. Both sensors successfully exhibit a remarkably 'turn-on' response, toward Fe(3+) , which was attributed to 1: 2 complex formation between Fe(3+) and L(1) /L(2) . The fluorescent and colorimetric response to Fe(3+) can be detected by the naked eye, which provides a facile method for the visual detection of Fe(3+) . Copyright © 2014 John Wiley & Sons, Ltd.
EDTA analysis on the Roche MODULAR analyser.
Davidson, D F
2007-05-01
Patient specimens can be subject to subtle interference from cross contamination by liquid-based, potassium-containing EDTA anticoagulant, leading to misinterpretation of results. A rapid method for EDTA analysis to detect such contamination is described. An in-house EDTA assay on the Roche MODULAR analyser was assessed for accuracy and precision by comparison with an adjusted calcium difference measurement (atomic absorption and o-cresolphthalein complexone colorimetry). EDTA method versus adjusted calcium difference showed: slope = 1.038 (95% confidence interval [CI] 0.949-1.131); intercept = 0.073 (95% CI 0.018-0.132) mmol/L; r = 0.914; n = 94. However, inter-assay precision of the calcium difference method was estimated to be poorer (coefficient of variation 24.8% versus 3.4% for the automated colorimetric method at an EDTA concentration of 0.25 mmol/L). Unequivocal contamination was observed at an EDTA concentration of > or =0.2 mmol/L. The automated method showed positive interference from haemolysis and negative interference from oxalate. The method was unaffected by lipaemia (triglycerides <20 mmol/L), icterus (bilirubin <500 micromol/L), glucose (<100 mmol/L), iron (<100 micromol/L), and citrate, phosphate or fluoride (all <2.5 mmol/L). The automated colorimetric assay described is an accurate, precise and rapid (3 min) means of detecting EDTA contamination of unhaemolysed biochemistry specimens.
Sulfuric acid/hydrogen peroxide digestion and colorimetric a collaborative study.
Christians, D K; Aspelund, T G; Brayton, S V; Roberts, L L
1991-01-01
Seven laboratories participated in a collaborative study of a method for determination of phosphorus in meat and meat products. Samples are digested in sulfuric acid and hydrogen peroxide; digestion is complete in approximately 10 min. Phosphorus is determined by colorimetric analysis of a dilute aliquot of the sample digest. The collaborators analyzed 3 sets of blind duplicate samples from each of 6 classes of meat (U.S. Department of Agriculture classifications): smoked ham, water-added ham, canned ham, pork sausage, cooked sausage, and hamburger. The calibration curve was linear over the range of standard solutions prepared (phosphorus levels from 0.05 to 1.00%); levels in the collaborative study samples ranged from 0.10 to 0.30%. Standard deviations for repeatability (sr) and reproducibility (SR) ranged from 0.004 to 0.012 and 0.007 to 0.014, respectively. Corresponding relative standard deviations (RSDr and RSDR, respectively) ranged from 1.70 to 7.28% and 3.50 to 9.87%. Six laboratories analyzed samples by both the proposed method and AOAC method 24.016 (14th Ed.). One laboratory reported results by the proposed method only. Statistical evaluations indicated no significant difference between the 2 methods. The method has been adopted official first action by AOAC.
A digital image method of spot tests for determination of copper in sugar cane spirits
NASA Astrophysics Data System (ADS)
Pessoa, Kenia Dias; Suarez, Willian Toito; dos Reis, Marina Ferreira; de Oliveira Krambeck Franco, Mathews; Moreira, Renata Pereira Lopes; dos Santos, Vagner Bezerra
2017-10-01
In this work the development and validation of analytical methodology for determination of copper in sugarcane spirit samples is carried out. The digital image based (DIB) method was applied along with spot test from the colorimetric reaction employing the RGB color model. For the determination of copper concentration, it was used the cuprizone - a bidentate organic reagent - which forms with copper a blue chelate in an alkaline medium. A linear calibration curve over the concentration range from 0.75 to 5.00 mg L- 1 (r2 = 0.9988) was obtained and limits of detection and quantification of 0.078 mg L- 1 and 0.26 mg L- 1 were acquired, respectively. For the accuracy studies, recovery percentages ranged from 98 to 104% were obtained. The comparison of cooper concentration results in sugar cane spirits using the DIB method and Flame Atomic Absorption Spectrometry as reference method showed no significant differences between both methods, which were performed using the paired t-test in 95% of confidence level. Thus, the spot test method associated with DIB allows the use of devices as digital cameras and smartphones to evaluate colorimetric reaction with low waste generation, practicality, quickness, accuracy, precision, high portability and low-cost.
MATRIX DISCRIMINANT ANALYSIS WITH APPLICATION TO COLORIMETRIC SENSOR ARRAY DATA
Suslick, Kenneth S.
2014-01-01
With the rapid development of nano-technology, a “colorimetric sensor array” (CSA) which is referred to as an optical electronic nose has been developed for the identification of toxicants. Unlike traditional sensors which rely on a single chemical interaction, CSA can measure multiple chemical interactions by using chemo-responsive dyes. The color changes of the chemo-responsive dyes are recorded before and after exposure to toxicants and serve as a template for classification. The color changes are digitalized in the form of a matrix with rows representing dye effects and columns representing the spectrum of colors. Thus, matrix-classification methods are highly desirable. In this article, we develop a novel classification method, matrix discriminant analysis (MDA), which is a generalization of linear discriminant analysis (LDA) for the data in matrix form. By incorporating the intrinsic matrix-structure of the data in discriminant analysis, the proposed method can improve CSA’s sensitivity and more importantly, specificity. A penalized MDA method, PMDA, is also introduced to further incorporate sparsity structure in discriminant function. Numerical studies suggest that the proposed MDA and PMDA methods outperform LDA and other competing discriminant methods for matrix predictors. The asymptotic consistency of MDA is also established. R code and data are available online as supplementary material. PMID:26783371
Analysis of antioxidative phenolic compounds in artichoke (Cynara scolymus L.).
Wang, Mingfu; Simon, James E; Aviles, Irma Fabiola; He, Kan; Zheng, Qun-Yi; Tadmor, Yaakov
2003-01-29
Artichoke leaf is an herbal medicine known for a long time. A systematic antioxidant activity-directed fractionation procedure was used to purify antioxidative components from the aqueous methanol extractions of artichoke heads and leaves in this study. Seven active polyphenolic compounds were purified from artichoke, and structural elucidation of each was achieved using MS and NMR. Two of these compounds, apigenin-7-rutinoside and narirutin, were found to be unique to artichoke heads, this represents the first report of these compounds in the edible portion of this plant. The contents of these antioxidants and total phenols in dried artichoke samples from leaves and immature and mature heads of three varieties, Imperial Star, Green Globe, and Violet, were then analyzed and compared by colorimetric and validated HPLC methods. Significant differences by variety and plant organ were observed.
ERIC Educational Resources Information Center
Shaver, Lee Alan; Leung, Sam H.; Puderbaugh, Amy; Angel, Stephen A.
2011-01-01
The determination of total phenolics in foods and fruit juices was used successfully as a laboratory experiment in our undergraduate general, organic, and biological (GOB) chemistry course. Two different colorimetric methods were used over three years and comparative student results indicate that a ferrous ammonium sulfate (FAS) indicator…
Sutariya, Pinkesh G; Pandya, Alok; Lodha, Anand; Menon, Shobhana K
2016-01-15
A new, simple, ultra-sensitive and selective approach has been reported for the "on spot" colorimetric detection of creatinine based on calix[4]arene functionalized gold nanoparticles (AuNPs) with excellent discrimination in the presence of other biomolecules. The lower detection limit of the method is 2.16nM. The gold nanoparticles and p-tert-butylcalix[4]arene were synthesized by microwave assisted method. Specifically, in our study, we used dynamic light scattering (DLS) which is a powerful method for the determination of small changes in particle size, improved selectivity and sensitivity of the creatinine detection system over colorimetric method. The nanoassembly is characterized by Transmission electron microscopy (TEM), DLS, UV-vis and ESI-MS spectroscopy, which demonstrates the binding affinity due its ability of hydrogen bonding and electrostatic interaction between -NH group of creatinine and pSDSC4. It exhibits fast response time (<60s) to creatinine and has long shelf-life (>5 weeks). The developed pSDSC4-AuNPs based creatinine biosensor will be established as simple, reliable and accurate tool for the determination of creatinine in human urine samples. Copyright © 2015 Elsevier B.V. All rights reserved.
Nitschke, Jörg; Modick, Hendrik; Busch, Ekkehard; von Rekowski, Reimund Wantoch; Altenbach, Hans-Josef; Mölleken, Helga
2011-07-15
Mushroom β-glucans are known for their activity as biological response modifiers and anticarcinogenic agents. β-1,3-1,6 Branched glucans with a triple helix tertiary structure are recognised as the most potent ones. In the present work, a colorimetric method for β-1,3-1,6-glucan quantification based on the dye Congo red is introduced. This method is specific for β-glucans with a triple helix. The β-1,3-1,6-glucan content of mycelia and fruiting bodies from various mushrooms was determined and compared with the total β-1,3-glucan content, measured by a fluorimetric method. The results show equal amounts of β-1,3-1,6- and total β-1,3-glucans in the analysed species but obvious differences between mycelia and fruiting bodies. On the average, 3% of mycelia and 8% of fruiting body dry mass consist of β-1,3-1,6-glucans. The average percentage of β-1,3-1,6-glucans in the total β-1,3-glucan content differs between mycelia (46%) and fruiting bodies (87%). Copyright © 2011 Elsevier Ltd. All rights reserved.
Maheswari, Palanisamy Uma; Renuga, Duraisamy; Henry, Linda Jeeva Kumari; Ruckmani, Kandasamy
2018-04-30
The (E)-2-((2-hydrohy-5-methylphenylimino) methyl) phenol ligand was synthesized. The receptor was characterized by IR, 1 H and 13 C NMR and CHN analysis. The ligand exhibits colorimetric and fluorometric sensing of Zn 2+ and Mg 2+ ions in semi-aqueous medium (DMSO-H2O). The receptor was tested with series of transition metal ions (Cr 2+ , Fe 2+ , Ni 2+ , Co 2+ , Cu 2+ , Zn 2+ ) and heavy metal ions (Sn 2+ , Pd 2+ , Ce 2+ , Hg 2+ , Cd 2+ ) and the essential human body elements like Ca 2+ , Mg 2+ , Na + and K + ions. The naked eye colorimetric sensing was absorbed only for Zn 2+ and Mg 2+ . Both ions (ZnCl 2 and MgCl 2 in H 2 O), when added to the colorless solutions of the receptor of about 1 equivalence in incremental additions turn the solution into bright turmeric yellow. All other ions remain inactive, in colorimetric sensing. Further the Zn 2+ and Mg 2+ ions were probed by absorption and emission spectroscopy through incremental addition of respective metal ions. The in-situ deprotonation of the ligand on both Mg 2+ and Zn 2+ ions binding was confirmed by 1 H NMR titration studies. The imino nitrogen of the receptor is not coordinated to the metal ions. The Job's plot studies reveal the 1:2 binding ratio of metal ions to the receptor. The high fold fluorescence output on metal ions binding was positively used to sense the Zn 2+ and Mg 2+ ions, separately and together in HeLa cancer cells through cell imaging. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Wang, Qing; Yang, Xiaohan; Yang, Xiaohai; Liu, Pei; Wang, Kemin; Huang, Jin; Liu, Jianbo; Song, Chunxia; Wang, Jingjing
2015-02-01
A novel unmodified gold nanoparticles (AuNPs)-based colorimetric strategy for label-free, specific and sensitive mercury ion (Hg2+) detection was demonstrated by using thymine-Hg2+-thymine (T-Hg2+-T) recognition mechanism and hybridization chain reaction (HCR) amplification strategy. In this protocol, a structure-switching probe (H0) was designed to recognize Hg2+ and then propagated a chain reaction of hybridization events between two other hairpin probes (H1 and H2). In the absence of Hg2+, all hairpin probes could stably coexist in solution, the exposed sticky ends of hairpin probes were capable of stabilizing AuNPs. As a result, salt-induced AuNPs aggregation could be effectively prevented. In the presence of Hg2+, thymine bases of H0 could specifically interact with Hg2+ to form stable T-Hg2+-T complex. Consequently, the hairpin structure of H0 probe was changed. As H1/H2 probes were added, the HCR process could be triggered and nicked double-helixes were formed. Since it was difficult for the formed nicked double-helixes to inhibit salt-induced AuNPs aggregation, a red-to-blue color change was observed in the colloid solution as the salt concentration increased. With the elegant amplification effect of HCR, a detection limit of around 30 nM was achieved (S/N = 3), which was about 1-2 orders of magnitudes lower than that of previous unmodified AuNPs-based colorimetric methods. By using the T-Hg2+-T recognition mechanism, high selectivity was also obtained. As an unmodified AuNPs-based colorimetric strategy, the system was simple in design, convenient in operation, and eliminated the requirements of separation processes, chemical modifications, and sophisticated instrumentations.
Detection and Spatial Mapping of Mercury Contamination in Water Samples Using a Smart-Phone
2014-01-20
Au NP) and aptamer based colorimetric transmission assay that is implemented in disposable test tubes. With this smart-phone attachment that weighs...detection . colorimetric sensor . gold nanoparticles . aptamers A RTIC LE Terms of Use WEI ET AL. VOL. 8 ’ NO. 2 ’ 1121–1129 ’ 2014 www.acsnano.org 1122...a colorimetric assay utilizing citrate-stabilized plasmonic AuNPs and aptamers (Apt) mixed within disposable test tubes. Due to the shift in the
Optical resonance-enhanced absorption-based near-field immunochip biosensor for allergen detection.
Maier, Irene; Morgan, Michael R A; Lindner, Wolfgang; Pittner, Fritz
2008-04-15
An optical immunochip biosensor has been developed as a rapid method for allergen detection in complex food matrixes, and its application evaluated for the detection of the egg white allergens, ovalbumin and ovomucoid. The optical near-field phenomenon underlying the basic principle of the sensor design is called resonance-enhanced absorption (REA), which utilizes gold nanoparticles (Au NPs) as signal transducers in a highly sensitive interferometric setup. Using this approach, a novel, simple, and rapid colorimetric solid-phase immunoassay on a planar chip substrate was realized in direct and sandwich assay formats, with a detection system that does not require any instrumentation for readout. Semiquantitative immunochemical responses are directly visible to the naked eye of the analyst. The biosensor shows concentration-dependent color development by capturing antibody-functionalized Au NPs on allergen-coated chips and has a detection limit of 1 ng/mL. To establish a rapid method, we took advantage of the physicochemical microenvironment of the Au NP-antibody bioconjugate to be bound directly over an interacting poly(styrene-methyl methacrylate) interlayer by an immobilized antigen. In the direct assay format, a coating time with allergen of only 5 min under "soft" nondenaturing conditions was sufficient for accurate reproducibility and sensitivity. In conclusion, the REA-based immunochip sensor is easy to fabricate, is reproducible and selective in its performance, has minimal technical requirements, and will enable high-throughput screening of affinity binding interactions in technological and medical applications.
Characterization of indoor diesel exhaust emissions from the parking garage of a school.
Debia, Maximilien; Trachy-Bourget, Marie-Claude; Beaudry, Charles; Neesham-Grenon, Eve; Perron, Stéphane; Lapointe, Caroline
2017-02-01
Diesel exhaust (DE) emissions from a parking garage located in the basement of a school were characterized during spring and winter using direct reading devices and integrated sampling methods. Concentrations of CO and NO 2 were evaluated using electrochemical sensors and passive colorimetric tubes, respectively. Elemental and total carbon concentrations were measured using the NIOSH 5040 method. Particle number concentrations (PNCs), respirable particulate matter (PM resp ) mass concentrations, and size distributions were evaluated using direct reading devices. Indoor concentrations of elemental carbon, PNC, CO, and NO 2 showed significant seasonal variation; concentrations were much higher during winter (p < 0.01). Concentrations of the PM resp and total carbon did not show significant seasonal variation. Pearson correlation coefficients were 0.9 (p < 0.01) and 0.94 (p < 0.01) between the parking garage and ground floor average daily PNCs, and between the parking garage and first floor average daily PNCs, respectively. Since DE is the main identified source of fine and ultrafine particles in the school, these results suggest that DE emissions migrate from the parking garage into the school. Our results highlight the relevance of direct reading instruments in identifying migration of contaminants and suggest that monitoring PNC is a more specific way of assessing exposure to DE than monitoring the common PM resp fraction.
Saleh, Mona; El-Matbouli, Mansour
2015-06-01
Cyprinid herpesvirus-3 (CyHV-3) is a highly infectious pathogen that causes fatal disease in common and koi carp Cyprinus carpio L. CyHV-3 detection is usually based on virus propagation or amplification of the viral DNA using the PCR or LAMP techniques. However, due to the limited susceptibility of cells used for propagation, it is not always possible to successfully isolate CyHV-3 even from tissue samples that have high virus titres. All previously described detection methods including PCR-based assays are time consuming, laborious and require specialized equipment. To overcome these limitations, gold nanoparticles (AuNPs) have been explored for direct and sensitive detection of DNA. In this study, a label-free colorimetric nanodiagnostic method for direct detection of unamplified CyHV-3 DNA using gold nanoparticles is introduced. Under appropriate conditions, DNA probes hybridize with their complementary target sequences in the sample DNA, which results in aggregation of the gold nanoparticles and a concomitant colour change from red to blue, whereas test samples with non complementary DNA sequences remain red. In this study, gold nanoparticles were used to develop and evaluate a specific and sensitive hybridization assay for direct and rapid detection of the highly infectious pathogen termed Cyprinid herpesvirus-3. Copyright © 2015 Elsevier B.V. All rights reserved.
Gauthier, David T.; Cartwright, Deborah D.; Densmore, Christine L.; Blazer, Vicki; Ottinger, Christopher A.
2003-01-01
In this study we present a method for the measurement of in vitro mitogenesis in fish leucocytes that is based on the incorporation of the thymidine analogue 5′-bromo-2′-deoxyuridine (BrdU) into the DNA of replicating cells, followed by ELISA-based detection. This technique, adapted from methods developed for mammalian cells, operates on a similar biological principle to 3H-thymidine incorporation, but circumvents the logistical and safety issues inherent with the radioactive label. Because it directly measures DNA proliferation, the assay has advantages over other colorimetric methods that may be strongly influenced by leucocyte metabolic status. Using BrdU incorporation followed by ELISA, we evaluate the responsiveness of rainbow trout (Oncorhynchus mykiss [Walbaum]) leucocytes to the mammalian T-cell mitogen Concanavalin A (Con A) as well as the differential response of white perch (Morone americana [Gmelin]) leucocytes to Con A and pokeweed mitogen. Specific considerations intrinsic to the assay system are discussed, including the implications of utilising enzyme-based detection.
Green, Michael D.; Hostetler, Dana M.; Nettey, Henry; Swamidoss, Isabel; Ranieri, Nicola; Newton, Paul N.
2015-01-01
The availability of falsified antimalarial drugs can be reduced with effective drug regulatory agencies and proper enforcement. Fundamental to these agencies taking action, rapid identification must be made as soon as they appear in the market place. Since falsified antimalarials occur mostly in developing countries, performing drug analysis presents itself with unique challenges. A fundamental factor in choosing a useful technique is affordability and simplicity. Therefore, we suggest a three-tiered drug evaluation strategy for identifying a falsified drug in resource-poor areas. Tier I is a simple comparison of a tablet's weight and dimensions with official specifications. Tier II uses inexpensive photometric devices (laser and fluorescence) to evaluate a tablet. Suspicious samples from Tier I and II assessments are then subjected to a colorimetric assay for active ingredients identification and quantification. In this article, we evaluate a novel colorimetric assay for the simultaneous assessment of both lumefantrine and artemether in co-formulated Coartem™ tablets, and integrate the method with two novel, low-cost, fluorescence and laser photometric devices. Image analysis software is used for the assessments. Although artemether–lumefantrine is used as an example, the strategy may be adapted to other medicines. PMID:25897066
Abnous, Khalil; Danesh, Noor Mohammad; Ramezani, Mohammad; Taghdisi, Seyed Mohammad; Emrani, Ahmad Sarreshtehdar
2018-08-22
Herein, a novel colorimetric aptasensor was introduced for detection of cocaine based on the formation of three-way junction pockets on the surfaces of gold nanoparticles (AuNPs) and the catalytic activity of the surfaces of AuNPs. Simplicity and detection of cocaine in a short time (only 35 min) are some of the unique features of the proposed sensing strategy. In the presence of cocaine, triple-fragment aptamer (TFA) forms on the surfaces of AuNPs, leading to a significant decrease of the catalytic activity of AuNPs and the color of samples remains yellow. In the absence of target, TFA does not form on the surfaces of AuNPs and 4-Nitrophenol, as a colorimetric agent, has more access to the surfaces of AuNPs, resulting in the reduction of 4-Nitrophenol and the color of sample changes from yellow to colorless. The sensing strategy showed good specificity, a limit of detection (LOD) of 440 pM and a dynamic range over 2-100 nM. The sensing method was also successfully applied to detect cocaine in spiked human serum samples with recovery of 94.71-98.63%. Copyright © 2018 Elsevier B.V. All rights reserved.
Green, Michael D; Hostetler, Dana M; Nettey, Henry; Swamidoss, Isabel; Ranieri, Nicola; Newton, Paul N
2015-06-01
The availability of falsified antimalarial drugs can be reduced with effective drug regulatory agencies and proper enforcement. Fundamental to these agencies taking action, rapid identification must be made as soon as they appear in the market place. Since falsified antimalarials occur mostly in developing countries, performing drug analysis presents itself with unique challenges. A fundamental factor in choosing a useful technique is affordability and simplicity. Therefore, we suggest a three-tiered drug evaluation strategy for identifying a falsified drug in resource-poor areas. Tier I is a simple comparison of a tablet's weight and dimensions with official specifications. Tier II uses inexpensive photometric devices (laser and fluorescence) to evaluate a tablet. Suspicious samples from Tier I and II assessments are then subjected to a colorimetric assay for active ingredients identification and quantification. In this article, we evaluate a novel colorimetric assay for the simultaneous assessment of both lumefantrine and artemether in co-formulated Coartem™ tablets, and integrate the method with two novel, low-cost, fluorescence and laser photometric devices. Image analysis software is used for the assessments. Although artemether-lumefantrine is used as an example, the strategy may be adapted to other medicines. © The American Society of Tropical Medicine and Hygiene.
Mirabal, Niuris C.; Yzquierdo, Sergio L.; Lemus, Dihadenys; Madruga, Mariela; Milián, Yoslaine; Echemendía, Miguel; Takiff, Howard; Martin, Anandi; Van der Stuyf, Patrick; Palomino, Juan Carlos; Montoro, Ernesto
2010-01-01
The direct detection of pyrazinamide resistance in Mycobacterium tuberculosis is sufficiently difficult that many laboratories do not attempt it. Most pyrazinamide resistance is caused by mutations that inactivate the pyrazinamidase enzyme needed to convert the prodrug pyrazinamide to its active form. We evaluated two newer and simpler methods to assess pyrazinamidase activity, the nitrate reductase and malachite green microtube assays, using nicotinamide in place of pyrazinamide. A total of 102 strains were tested by these methods and the results compared with those obtained by the classic Wayne assay. Mutations in the pncA gene were identified by sequencing the pncA genes from all isolates in which pyrazinamide resistance was detected by any of the three methods. Both the nitrate reductase and malachite green microtube assays showed sensitivities of 93.75% and specificities of 97.67%. Mutations in the pncA gene were found in 14 of 16 strains that were pyrazinamide resistant and in 1 of 4 strains that were sensitive by the Wayne assay. Both of these simple methods, used with nicotinamide, are promising and inexpensive alternatives for the rapid detection of pyrazinamide resistance in limited-resource countries. PMID:20554826
Catucci, Gianluca; Polignano, Isabelle; Cusumano, Debora; Medana, Claudio; Gilardi, Gianfranco; Sadeghi, Sheila J
2017-04-01
Human hepatic flavin-containing monooxygenase 3 is a phase I drug-metabolizing enzyme that is responsible for the oxidation of a variety of drugs and xenobiotics. This work reports on a high throughput rapid colorimetric assay for the screening of substrates or inhibitors of this enzyme. The method is based on the competition of two substrates for access to the active site of hFMO3 whereby the enzymatic product of the first drug converts nitro-5-thiobenzoate (TNB, yellow) to 5,5'-dithiobis (2-nitrobenzoate) (DTNB, colourless). Upon addition of a competing substrate, the amount of detected DNTB is decreased. The assay is validated testing three known substrates of hFMO3, namely benzydamine, tozasertib and tamoxifen. The latter drugs resulted in 41%-55% inhibition. In addition, two other drugs also classified as doping drugs, selegiline and clomiphene, were selected based on their chemical structure similarity to known substrates of hFMO3. These drugs showed 21% and 60% inhibition in the colorimetric assay and therefore were proven to be hFMO3 substrates. LC-MS was used to confirm their N-oxide products. Further characterisation of these newly identified hFMO3 substrates was performed determining their K m and k cat values that resulted to be 314 μM and 1.4 min -1 for selegiline and, 18 μM and 0.1 min -1 for clomiphene. This method paves the way for a rapid automated high throughput screening of nitrogen-containing compounds as substrates/inhibitors of hFMO3. Copyright © 2017 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Dietrich, Nicolas; Hebrard, Gilles
2018-02-01
An approach for visualizing and measuring the mass transfer around a single bubble rising in a quiescent liquid is reported. A colorimetric technique, developed by (Dietrich et al. Chem Eng Sci 100:172-182, 2013) using an oxygen sensitive redox dye was implemented. It was based on the reduction of the colorimetric indicator in presence of oxygen, this reduction being catalysed by sodium hydroxide and glucose. In this study, resazurin was selected because it offered various reduced forms with colours ranging from transparent (without oxygen) to pink (in presence of oxygen). These advantages made it possible to visualize the spatio-temporal oxygen mass transfer around rising bubbles. Images were recorded by a CCD camera and, after post-processing, the shape, size, and velocity of the bubbles were measured and the colours around the bubbles mapped. A calibration, linking the level of colour with the dissolved oxygen concentration, enabled colour maps to be converted into oxygen concentration fields. A rheoscopic fluid was used to visualize the wake of the bubbles. A calculation method was also developed to determine the transferred oxygen fluxes around bubbles of two sizes (d = 0.82 mm and d = 2.12 mm) and the associated liquid-side mass transfer coefficients. The results compared satisfactorily with classical global measurements made by oxygen micro-sensors or from the classical models. This study thus constitutes a striking example of how this new colorimetric method could become a remarkable tool for exploring gas-liquid mass transfer in fluids.
NASA Astrophysics Data System (ADS)
Dietrich, Nicolas; Hebrard, Gilles
2018-07-01
An approach for visualizing and measuring the mass transfer around a single bubble rising in a quiescent liquid is reported. A colorimetric technique, developed by (Dietrich et al. Chem Eng Sci 100:172-182, 2013) using an oxygen sensitive redox dye was implemented. It was based on the reduction of the colorimetric indicator in presence of oxygen, this reduction being catalysed by sodium hydroxide and glucose. In this study, resazurin was selected because it offered various reduced forms with colours ranging from transparent (without oxygen) to pink (in presence of oxygen). These advantages made it possible to visualize the spatio-temporal oxygen mass transfer around rising bubbles. Images were recorded by a CCD camera and, after post-processing, the shape, size, and velocity of the bubbles were measured and the colours around the bubbles mapped. A calibration, linking the level of colour with the dissolved oxygen concentration, enabled colour maps to be converted into oxygen concentration fields. A rheoscopic fluid was used to visualize the wake of the bubbles. A calculation method was also developed to determine the transferred oxygen fluxes around bubbles of two sizes (d = 0.82 mm and d = 2.12 mm) and the associated liquid-side mass transfer coefficients. The results compared satisfactorily with classical global measurements made by oxygen micro-sensors or from the classical models. This study thus constitutes a striking example of how this new colorimetric method could become a remarkable tool for exploring gas-liquid mass transfer in fluids.
On-Board Monitoring of Engine Oil
2011-04-01
Viscosity of Transparent and Opaque Liquids at 40°C Infracal Soot Meter Karl Fischer Titration ASTM D 664 Standard Test Method for Acid Number of... methods involve potentiometric and colorimetric titrations, respectively. For both tests, a titration solvent is prepared and added to the oil. The...ASTM D 2896 and ASTM D 4739 [17]. Both methods involve potentiometric titrations. ASTM D 2896 uses a stronger acid and more polar solvent than ASTM D
Colorimetric values of esthetic stainless steel crowns.
Hosoya, Yumiko; Omachi, Koichi; Staninec, Michal
2002-01-01
The colorimetric values of two different kinds of esthetic stainless steel crowns were measured and compared with the colorimetric values of primary anterior teeth in Japanese children. The colorimetric values of resin composite-faced stainless steel crowns (Kinder Krown) and epoxy-coated stainless steel crowns (White Steel Crown) were measured with a color difference meter. The Commission Internationale de Eclairage L*, a*, b*, and delta E*ab values and Munsell value, chroma, and hue were calculated. The data were compared with previously reported colorimetric values of Japanese primary anterior teeth measured with the same color difference meter used in this study. Compared to Japanese primary anterior teeth, Kinder Krown Pedo I and Pedo II showed much higher L* values and lower hue; on the other hand, White Steel Crown showed much higher L*, a*, b* values, much higher value and chroma, and much lower hue. Color analysis revealed that the colors of the White Steel Crown and Kinder Krown Pedo I were substantially different from the color of Japanese primary anterior teeth. The color difference between Pedo II crowns and Japanese primary anterior teeth was relatively high, but the color of Pedo II might be acceptable for clinical use.
Guo, Jian-Feng; Huo, Dan-Qun; Yang, Mei; Hou, Chang-Jun; Li, Jun-Jie; Fa, Huan-Bao; Luo, Hui-Bo; Yang, Ping
2016-12-01
Herein, we have developed a simple, sensitive and paper-based colorimetric sensor for the selective detection of Chromium (Ⅵ) ions (Cr (VI)). Silanization-titanium dioxide modified filter paper (STCP) was used to trap bovine serum albumin capped gold nanoparticles (BSA-Au NPs), leading to the fabrication of BSA-Au NPs decorated membrane (BSA-Au NPs/STCP). The BSA-Au NPs/STCP operated on the principle that BSA-Au NPs anchored on the STCP were gradually etched by Cr (VI) as the leaching process of gold in the presence of hydrobromic acid (HBr) and hence induced a visible color change. Under optimum conditions, the paper-based colorimetric sensor showed clear color change after reaction with Cr (VI) as well as with favorable selectivity to a variety of possible interfering counterparts. The amount-dependent colorimetric response was linearly correlated with the Cr (VI) concentrations ranging from 0.5µM to 50.0µM with a detection limit down to 280nM. Moreover, the developed cost-effective colorimetric sensor has been successfully applied to real environmental samples which demonstrated the potential for field applications. Copyright © 2016 Elsevier B.V. All rights reserved.
Photonic Crystal Structures with Tunable Structure Color as Colorimetric Sensors
Wang, Hui; Zhang, Ke-Qin
2013-01-01
Colorimetric sensing, which transduces environmental changes into visible color changes, provides a simple yet powerful detection mechanism that is well-suited to the development of low-cost and low-power sensors. A new approach in colorimetric sensing exploits the structural color of photonic crystals (PCs) to create environmentally-influenced color-changeable materials. PCs are composed of periodic dielectrics or metallo-dielectric nanostructures that affect the propagation of electromagnetic waves (EM) by defining the allowed and forbidden photonic bands. Simultaneously, an amazing variety of naturally occurring biological systems exhibit iridescent color due to the presence of PC structures throughout multi-dimensional space. In particular, some kinds of the structural colors in living organisms can be reversibly changed in reaction to external stimuli. Based on the lessons learned from natural photonic structures, some specific examples of PCs-based colorimetric sensors are presented in detail to demonstrate their unprecedented potential in practical applications, such as the detections of temperature, pH, ionic species, solvents, vapor, humidity, pressure and biomolecules. The combination of the nanofabrication technique, useful design methodologies inspired by biological systems and colorimetric sensing will lead to substantial developments in low-cost, miniaturized and widely deployable optical sensors. PMID:23539027
NAA For Human Serum Analysis: Comparison With Conventional Analyses
DOE Office of Scientific and Technical Information (OSTI.GOV)
Oliveira, Laura C.; Zamboni, Cibele B.; Medeiros, Jose A. G.
2010-08-04
Instrumental and Comparator methods of Neutron Activation Analysis (NAA) were applied to determine elements of clinical relevancy in serum samples of adult population (Sao Paulo city, Brazil). A comparison with the conventional analyses, Colorimetric for calcium, Titrymetric for chlorine and Ion Specific Electrode for sodium and potassium determination were also performed permitting a discussion about the performance of NAA methods for clinical chemistry research.
Assessment of Remaining Lubricant Life
1986-11-01
tioxidant, inexpensive spectrophotometers are used. However, the greatest advantage of the Mitsubishi chemical stressing technique was the fact that it uses...samples, the method’s main advantage over the thermal stressing techniques is eliminated. The colorimetric method had the advantage over induction period...decrease of 18 torr. The main advantage of defining the induction period in this manner is that it eliminates any need for interpretation by the
Oxalate analysis methodology for decayed wood
Carol A. Clausen; William Kenealy; Patricia K. Lebow
2008-01-01
Oxalate from partially decayed southern pine wood was analyzed by HPLC or colorimetric assay. Oxalate extraction efficiency, assessed by comparing analysis of whole wood cubes with ground wood, showed that both wood geometries could be extracted with comparable efficiency. To differentiate soluble oxalate from total oxalate, three extraction methods were assessed,...
A net fishing enrichment strategy for colorimetric detection of E. coli O157:H7
USDA-ARS?s Scientific Manuscript database
The strict regulatory requirements for pathogen monitoring in food systems to ensure safety demands that the detection method can recognize small numbers of pathogens. Although significant efforts on the development of biosensors have been reported with marked improvement in sensitivity, appropriate...
40 CFR 63.323 - Test methods and monitoring.
Code of Federal Regulations, 2012 CFR
2012-07-01
... downstream from any flow disturbance such as a bend, expansion, contraction, or outlet; downstream from no other inlet; and 2 stack or duct diameters upstream from any flow disturbance such as a bend, expansion... monitoring by inserting the colorimetric detector or PCE gas analyzer tube into the open space above the...
40 CFR 63.323 - Test methods and monitoring.
Code of Federal Regulations, 2014 CFR
2014-07-01
... downstream from any flow disturbance such as a bend, expansion, contraction, or outlet; downstream from no other inlet; and 2 stack or duct diameters upstream from any flow disturbance such as a bend, expansion... monitoring by inserting the colorimetric detector or PCE gas analyzer tube into the open space above the...
40 CFR 63.323 - Test methods and monitoring.
Code of Federal Regulations, 2013 CFR
2013-07-01
... downstream from any flow disturbance such as a bend, expansion, contraction, or outlet; downstream from no other inlet; and 2 stack or duct diameters upstream from any flow disturbance such as a bend, expansion... monitoring by inserting the colorimetric detector or PCE gas analyzer tube into the open space above the...
Rapid quantification of proanthocyanidins (condensed tannins) with a continuous flow analyzer
James K. Nitao; Bruce A. Birr; Muraleedharan G. Nair; Daniel A. Herms; William J. Mattson
2001-01-01
Proanthocyanidins (condensed tannins) frequently need to be quantified in large numbers of samples in food, plant, and environmental studies. An automated colorimetric method to quantify proanthocyanidins with sulfuric acid (H2SO4) was therefore developed for use in a continuous flow analyzer. Assay conditions were...
Characterization of Soil Samples of Enzyme Activity
ERIC Educational Resources Information Center
Freeland, P. W.
1977-01-01
Described are nine enzyme essays for distinguishing soil samples. Colorimetric methods are used to compare enzyme levels in soils from different sites. Each soil tested had its own spectrum of activity. Attention is drawn to applications of this technique in forensic science and in studies of soil fertility. (Author/AJ)
ERIC Educational Resources Information Center
Harley, Suzanne M.
1993-01-01
Nitrate assimilation by plants provides an excellent system for demonstrating control of gene expression in a eukaryotic organism. Describes an assay method that allows students to complete experiments designed around the measurement of nitrate reductase within a three-hour laboratory experiment. (PR)
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cellini, R.F.; Sanchez, L.G.
1956-01-01
Volumetric and colorimetric determinations of sulfur in uranium were carried out by acid treatment and evaluation of SH/sup 2/. According to the experimental results a discussion of both methods was made. (auth)
NASA Astrophysics Data System (ADS)
Kim, Jong H.
2018-03-01
In this work, an efficient colorimetric chemosensor for the detection of ethylamines using a pyridinium salt (the Zincke salt) is reported. Highly sensitive and selective reactivity of the Zincke salt enables colorimetric response of the Zincke salt solution to the ethylamines by showing well-defined visible color changes from colorless to the deep red. Furthermore, the Zincke salt thin film exhibits discernable color changes in response to ethylamine gas as well, which allows fabrication of simple, fast and portable strip- and textile-type ethylamine sensors.
Velmathi, Sivan; Reena, Vijayaraghavan; Suganya, Sivalingam; Anandan, Sambandam
2012-01-01
An efficient colorimetric sensor with pyrrole-NH moiety as binding site and nitro group as a signaling unit has been synthesized by a one step procedure and characterized by spectroscopic techniques, which displays excellent selectivity and sensitivity for fluoride and hydroxide ions. The hydrogen bonding with these anions provides remarkable colorimetric responses. (1)H NMR and FT IR studies has been carried out to confirm the hydrogen bonding. UV-vis and fluorescence spectral changes can be exploited for real time and on site application.
Simple, field portable colorimetric detection device for organic peroxides and hydrogen peroxide
Pagoria, Philip F.; Mitchell, Alexander R.; Whipple, Richard E.; Carman, M. Leslie; Reynolds, John G.; Nunes, Peter; Shields, Sharon J.
2010-11-09
A simple and effective system for the colorimetric determination of organic peroxides and hydrogen peroxide. A peroxide pen utilizing a swipe material attached to a polyethylene tube contains two crushable vials. The two crushable vials contain a colorimetric reagent separated into dry ingredients and liquid ingredients. After swiping a suspected substance or surface the vials are broken, the reagent is mixed thoroughly and the reagent is allowed to wick into the swipe material. The presence of organic peroxides or hydrogen peroxide is confirmed by a deep blue color.
Mahapatra, Ajit Kumar; Manna, Saikat Kumar; Maiti, Kalipada; Mondal, Sanchita; Maji, Rajkishor; Mandal, Debasish; Mandal, Sukhendu; Uddin, Md Raihan; Goswami, Shyamaprosad; Quah, Ching Kheng; Fun, Hoong-Kun
2015-02-21
Azodye-rhodamine hybrid colorimetric fluorescent probe (L) has been designed and synthesized. The structure of L has been established based on single crystal XRD. It has been shown to act as a selective turn-on fluorescent chemosensor for Pd(2+) with >40 fold enhancement by exhibiting red emission among the other 27 cations studied in aqueous ethanol. The coordination features of the species of recognition have been computationally evaluated by DFT methods and found to have a distorted tetrahedral Pd(2+) center in the binding core. The probe (L) has been shown to detect Pd up to 0.45 μM at pH 7.4. Furthermore, the probe can be used to image Pd(2+) in living cells.
Colorimetric monitoring of solid-phase aldehydes using 2,4-dinitrophenylhydrazine.
Shannon, Simon K; Barany, George
2004-01-01
A simple and rapid method to achieve colorimetric monitoring of resin-bound aldehydes, based on ambient temperature reaction with 2,4-dinitrophenylhydrazine (DNPH) in the presence of dilute acid, has been developed as an adjunct to solid-phase organic synthesis and combinatorial chemistry. By this test, the presence of aldehydes is indicated by a red to dark-orange appearance, within a minute. Alternatively, resins that are free of aldehydes or in which aldehyde functions have reacted completely retain their original color. The DNPH test was demonstrated for poly(ethylene glycol)-polystyrene (PEG-PS), aminomethyl polystyrene (AMP), cross-linked ethoxylate acrylate resin (CLEAR), and acryloylated O,O'-bis(2-aminopropyl)poly(ethylene glycol) (PEGA) supports and gave results visible to the naked eye at levels as low as 18 micromol of aldehyde per gram of resin.
Methodology for constructing a colour-difference acceptability scale.
Laborie, Baptiste; Viénot, Françoise; Langlois, Sabine
2010-09-01
Observers were invited to report their degree of satisfaction on a 6-point semantic scale with respect to the conformity of a test colour with a white reference colour, simultaneously presented on a PDP display. Eight test patches were chosen along each of the +a*, -a*, +b*, -b* axes of the CIELAB chromaticity plane, at Y = 80 ± 2 cd.m(-2) . Experimental conditions reliably represented the automotive environment (patch size, angular distance between patches) and observers could move their head and eyes freely. We have compared several methods of category scaling, the Torgerson-DMT method (Torgerson, W. S. (1958). Theory and methods of scaling. Wiley, New York, USA); two versions of the regression method i.e. Bonnet's (Bonnet, C. (1986). Manuel pratique de psychophysique. Armand Colin, Paris, France) and logistic regression; and the medians method. We describe in detail a case where all methods yield substantial but slightly different results. The solution proposed by the regression method which works with incomplete matrices and yields results directly on a colorimetric scale is probably the most useful in this industrial context. Finally we summarize the implementation of the logistic regression method over four hues and for one experimental condition. © 2010 The Authors, Ophthalmic and Physiological Optics © 2010 The College of Optometrists.
Dutta, Sibasish; Saikia, Gunjan Prasad; Sarma, Dhruva Jyoti; Gupta, Kuldeep; Das, Priyanka; Nath, Pabitra
2017-05-01
In this paper the utilization of smartphone as a detection platform for colorimetric quantification of biological macromolecules has been demonstrated. Using V-channel of HSV color space, the quantification of BSA protein, catalase enzyme and carbohydrate (using D-glucose) have been successfully investigated. A custom designed android application has been developed for estimating the total concentration of biological macromolecules. The results have been compared with that of a standard spectrophotometer which is generally used for colorimetric quantification in laboratory settings by measuring its absorbance at a specific wavelength. The results obtained with the designed sensor is found to be similar when compared with the spectrophotometer data. The designed sensor is low cost, robust and we envision that it could promote diverse fields of bio-analytical investigations. Schematic illustration of the smartphone sensing mechanism for colorimetric analysis of biomolecular samples. © 2017 Wiley-VCH Verlag GmbH & Co. KGaA, Weinheim.
Integrating Deoxyribozymes into Colorimetric Sensing Platforms
Chang, Dingran; Zakaria, Sandy; Deng, Mimi; Allen, Nicholas; Tram, Kha; Li, Yingfu
2016-01-01
Biosensors are analytical devices that have found a variety of applications in medical diagnostics, food quality control, environmental monitoring and biodefense. In recent years, functional nucleic acids, such as aptamers and nucleic acid enzymes, have shown great potential in biosensor development due to their excellent ability in target recognition and catalysis. Deoxyribozymes (or DNAzymes) are single-stranded DNA molecules with catalytic activity and can be isolated to recognize a wide range of analytes through the process of in vitro selection. By using various signal transduction mechanisms, DNAzymes can be engineered into fluorescent, colorimetric, electrochemical and chemiluminescent biosensors. Among them, colorimetric sensors represent an attractive option as the signal can be easily detected by the naked eye. This reduces reliance on complex and expensive equipment. In this review, we will discuss the recent progress in the development of colorimetric biosensors that make use of DNAzymes and the prospect of employing these sensors in a range of chemical and biological applications. PMID:27918487
Delhaes, L; Lazaro, J E; Gay, F; Thellier, M; Danis, M
1999-01-01
Malarial lactate dehydrogenase (LDH), which uses 3-acetyl pyridine adenine dinucleotide as coenzyme in a reaction leading to the formation of pyruvate from L-lactate, may be used to study the susceptibility of Plasmodium falciparum to a drug in vitro. Several methods to determine the activity of this enzyme are available. One, the colorimetric method of Makler and colleagues, was modified slightly, by using sodium-2,3-bis-[2-methoxy-4-nitro-5-sulphophenyl]-2H-tetrazolium-5 - carboxanilide (XTT) and following the reaction by measuring the optical density at 450 nm. Using two, culture-adapted strains of P. falciparum, this LDH assay was compared with the unmodified Makler's assay and with the isotopic microtest based on the incorporation of tritium-labelled hypoxanthine. Fresh, clinical P. falciparum isolates were also tested in the presence of several drugs, including chloroquine, mefloquine, quinine, halofantrine, atovaquone and qinghaosu derivatives. The results of the three assays were correlated for all the drugs tested except atovaquone. The two enzymatic assays are non-radioactive, rapid, reliable, inexpensive to perform and semi-automatic. However, they do require an initial parasitaemia of 2% with a haematocrit of 1.8%.
Chen, Xi; Chen, Jin; Wang, Fubin; Xiang, Xia; Luo, Ming; Ji, Xinghu; He, Zhike
2012-05-15
In this work, we first employ a drying method combining with the bienzyme colorimetric detection of glucose and uric acid on microfluidic paper-based analysis devices (μPADs). The channels of 3D μPADs are also designed by us to get better results. The color results are recorded by both Gel Documentation systems and a common camera. By using Gel Documentation systems, the limits of detection (LOD) of glucose and uric acid are 3.81 × 10(-5)M and 4.31 × 10(-5)M, respectively one order of magnitude lower than that of the reported methods on μPADs. By using a common camera, the limits of detection (LOD) of glucose and uric acid are 2.13 × 10(-4)M and 2.87 × 10(-4)M, respectively. Furthermore, the effects of detection conditions have been investigated and discussed comprehensively. Human serum samples are detected with satisfactory results, which are comparable with the clinical testing results. A low-cost, simple and rapid colorimetric method for the simultaneous detection of glucose and uric acid on the μPADs has been developed with enhanced sensitivity. Copyright © 2012 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Larki, A.
2017-02-01
In this work, the intrinsic colorimetric property of carbon dots (CDs) was utilized for the determination of fenitrothion by applying dispersive liquid-liquid microextraction (DLLME) method. Label free CDs are extracted into carbon tetrachloride via assistance of trioctylmethylammonium chloride (Aliquat 336), which also acts as a disperser agent in this technique. The enriched CDs show an absorption signal at 365 nm, which increases in the presence of fenitrothion. The absorbance increase of CDs in organic phase was used as an analytical signal for the determination of fenitrothion. The synthesized CDs were characterized by UV-visible, fluorescence, Fourier transform infrared (FT-IR) and transmission electron microscopic (TEM). Under the optimized conditions, beer's law was obeyed in the range of 1.0-250.0 ng mL- 1 of fenitrothion with the limit of detection for fenitrothion was 0.2 ng mL- 1. The relative standard deviation for eight replicate measurements of fenitrothion at concentrations of 25 and 100 ng mL- 1 were calculated to be 1.5 and 3.7%, respectively. The proposed method was successfully applied in the determination of fenitrothion in water samples with satisfactory results.
Selective Distance-Based K+ Quantification on Paper-Based Microfluidics.
Gerold, Chase T; Bakker, Eric; Henry, Charles S
2018-04-03
In this study, paper-based microfluidic devices (μPADs) capable of K + quantification in aqueous samples, as well as in human serum, using both colorimetric and distance-based methods are described. A lipophilic phase containing potassium ionophore I (valinomycin) was utilized to achieve highly selective quantification of K + in the presence of Na + , Li + , and Mg 2+ ions. Successful addition of a suspended lipophilic phase to a wax printed paper-based device is described and offers a solution to current approaches that rely on organic solvents, which damage wax barriers. The approach provides an avenue for future alkali/alkaline quantification utilizing μPADs. Colorimetric spot tests allowed for K + quantification from 0.1-5.0 mM using only 3.00 μL of sample solution. Selective distance-based quantification required small sample volumes (6.00 μL) and gave responses sensitive enough to distinguish between 1.0 and 2.5 mM of sample K + . μPADs using distance-based methods were also capable of differentiating between 4.3 and 6.9 mM K + in human serum samples. Distance-based methods required no digital analysis, electronic hardware, or pumps; any steps required for quantification could be carried out using the naked eye.
NASA Astrophysics Data System (ADS)
Pourreza, Nahid; Lotfizadeh, Neda; Golmohammadi, Hamed
2018-03-01
In this research, a new colorimetric method for the determination of oxalate using curcumin nanoparticles (CURNs) in the presence Fe (III) is introduced. The method is based on the inhibitory effect of oxalate ion on the reaction of (CURNs) with Fe (III) in acidic media. This reaction was monitored by measuring the increase in absorbance of CURNs-Fe3 + complex in the presence of oxalate ion at 427 nm. The effect of different parameters such as the pH of the sample solution, concentration of Fe (III), concentration of CURNs and the reaction time was examined and optimized. Under optimum experimental conditions, the absorption intensity was linear with the concentration of oxalate in the range of 0.15 to 1.70 μg mL- 1. The limit of detection (LOD) was 0.077 μg mL- 1 and the relative standard deviations (RSD) for 8 replicate measurements of 0.40 and 1.05 μg mL- 1 of oxalate were 4.20% and 2.74%, respectively. The developed method was successfully employed to the determination of oxalate in water, food and urine samples with satisfactory results.
NASA Astrophysics Data System (ADS)
Wang, Huiying; Chen, Dinglong; Yu, Longquan; Chang, Ming; Ci, Lijie
2015-02-01
We have developed a rapid, sensitive, one-step, and selective colorimetric detection method for melamine (MEL) in milk powder based upon an in-situ formation of silver nanoparticles (AgNPs) through modified Tollens process at room temperature. The triazine ring N atoms of MEL molecule were strategically designed to complex the Ag+ through electron donor-acceptor interaction. During the AgNPs formation procedure, the MEL molecule, which has been covalently bonded with the Ag+ ions, was adsorbed to the surface of as-prepared AgNPs, resulting in the aggregation of the adjacent AgNPs with detectable decreases of absorption signal. The concentration of MEL can be determined with the naked eye or a UV-vis spectrometer at which the yellow-to-brown color change associated with aggregate enhancement takes place. This method enables rapid (less than 30 min) and sensitive (limit of detection, LOD, 10 nM) detection, and it was also able to discriminate MEL from sixteen other milk relevant coexisting compounds. This assay does not utilize organic cosolvents, enzymatic reactions, light-sensitive dye molecules, lengthy protocols, or sophisticated instrumentation thereby overcoming some of the limitations of conventional methods.
Programming function into mechanical forms by directed assembly of silk bulk materials
Patel, Nereus; Duggan, Thomas; Perotto, Giovanni; Shirman, Elijah; Li, Chunmei; Kaplan, David L.; Omenetto, Fiorenzo G.
2017-01-01
We report simple, water-based fabrication methods based on protein self-assembly to generate 3D silk fibroin bulk materials that can be easily hybridized with water-soluble molecules to obtain multiple solid formats with predesigned functions. Controlling self-assembly leads to robust, machinable formats that exhibit thermoplastic behavior consenting material reshaping at the nanoscale, microscale, and macroscale. We illustrate the versatility of the approach by realizing demonstrator devices where large silk monoliths can be generated, polished, and reshaped into functional mechanical components that can be nanopatterned, embed optical function, heated on demand in response to infrared light, or can visualize mechanical failure through colorimetric chemistries embedded in the assembled (bulk) protein matrix. Finally, we show an enzyme-loaded solid mechanical part, illustrating the ability to incorporate biological function within the bulk material with possible utility for sustained release in robust, programmably shapeable mechanical formats. PMID:28028213
A Review on Microfluidic Paper-Based Analytical Devices for Glucose Detection
Liu, Shuopeng; Su, Wenqiong; Ding, Xianting
2016-01-01
Glucose, as an essential substance directly involved in metabolic processes, is closely related to the occurrence of various diseases such as glucose metabolism disorders and islet cell carcinoma. Therefore, it is crucial to develop sensitive, accurate, rapid, and cost effective methods for frequent and convenient detections of glucose. Microfluidic Paper-based Analytical Devices (μPADs) not only satisfying the above requirements but also occupying the advantages of portability and minimal sample consumption, have exhibited great potential in the field of glucose detection. This article reviews and summarizes the most recent improvements in glucose detection in two aspects of colorimetric and electrochemical μPADs. The progressive techniques for fabricating channels on μPADs are also emphasized in this article. With the growth of diabetes and other glucose indication diseases in the underdeveloped and developing countries, low-cost and reliably commercial μPADs for glucose detection will be in unprecedentedly demand. PMID:27941634
Santos, Inês C; Mesquita, Raquel B R; Bordalo, Adriano A; Rangel, António O S S
2015-02-01
The present work describes the development of a sequential injection standard addition method for iodine speciation in bathing waters and seaweeds extracts without prior sample treatment. Iodine speciation was obtained by assessing the iodide and iodate content, the two inorganic forms of iodine in waters. For the determination of iodide, an iodide ion selective electrode (ISE) was used. The indirect determination of iodate was based on the spectrophotometric determination of nitrite (Griess reaction). For the iodate measurement, a mixing chamber was employed (flow batch approach) to explore the inherent efficient mixing, essential for the indirect determination of iodate. The application of the standard addition method enabled detection limits of 0.14 µM for iodide and 0.02 µM for iodate, together with the direct introduction of the target water samples, coastal and inland bathing waters. The results obtained were in agreement with those obtained by ICP-MS and a colorimetric reference procedure. Recovery tests also confirmed the accuracy of the developed method which was effectively applied to bathing waters and seaweed extracts. Copyright © 2014 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Alam, Md. Fazle; Laskar, Amaj Ahmed; Ahmed, Shahbaz; Shaida, Mohd. Azfar; Younus, Hina
2017-08-01
Melamine toxicity has recently attracted worldwide attention as it causes renal failure and the death of humans and animals. Therefore, developing a simple, fast and sensitive method for the routine detection of melamine is the need of the hour. Herein, we have developed a selective colorimetric method for the detection of melamine in milk samples based upon in-situ formation of silver nanoparticles (AgNPs) via tannic acid. The AgNPs thus formed were characterized by UV-Visible spectrophotometer, transmission electron microscope (TEM), zetasizer and dynamic light scattering (DLS). The AgNPs were used to detect melamine under in vitro condition and in raw milk spiked with melamine. Under optimal conditions, melamine could be selectively detected in vitro within the concentration range of 0.05-1.4 μM with a limit of detection (LOD) of 0.01 μM, which is lower than the strictest melamine safety requirement of 1 ppm. In spiked raw milk, the recovery percentage range was 99.5-106.5% for liquid milk and 98.5-105.5% for powdered milk. The present method shows extreme selectivity with no significant interference with other substances like urea, glucose, glycine, ascorbic acid etc. This assay method does not utilize organic cosolvents, enzymatic reactions, light sensitive dye molecules and sophisticated instrumentation, thereby overcoming some of the limitations of the other conventional methods.
Characterization analysis for leaves of Leucaena leucocephala by using phytochemical screening assay
NASA Astrophysics Data System (ADS)
Zarina, Z.; Ghazali, C. M. R.; Sam, S. T.
2017-09-01
Leucaena Leucocephala (Lam.) de Wit (Petai Belalang) is a medium plant which belong in group of tropical breed that can survived in hot, dried and warm environment. In Malaysia, the plant is available abundantly. As there are still no commercial used, and no serious intention in finding the benefits of L. Leucocephala, this work come out with the idea to analyze the antioxidants contains in leaves of the plant by undergoes different extraction and chemical testing method. The phytochemical screening assay involved in this study are antioxidant activity by using free radical diphenylpicrylhydrazyl (DPPH) method, total phenolic content by using Folin-Ciocalteu method, total flavonoid content by using colorimetric assay with ascorbic acid and quercetin were used as reference standards while for phosphorus analysis, a molybdenum blue method or also known as ascorbic acid method was used. For antioxidant activity by using free radical diphenylpicrylhydrazyl (DPPH) method, higher concentration was recorded by extraction using methanol (dried sample) which is 8247.0 mg/L, for total phenolic content higher concentration was recorded by extraction using deionized water (dried sample) which is 4276.0 mg/L, for total flavonoid content by using colorimetric assay higher concentration was recorded by extraction using methanol (dried sample) which is 4439.0 mg/L, and for for phosphorus analysis higher concentration was recorded by extraction using methanol (dried sample) which is 71.057 mg/L.
Characterization analysis for leaves of Leucaena Leucocephala by using phytochemical screening assay
NASA Astrophysics Data System (ADS)
Zarina, Z.; Ghazali, C. M. R.; Sam, S. T.
2017-09-01
Leucaena Leucocephala (Lam.) de Wit (Petai Belalang) is a medium plant which belong in group of tropical breed that can survived in hot, dried and warm environment. In Malaysia, the plant is available abundantly. As there are still no commercial used, and no serious intention in finding the benefits of L. Leucocephala, this work come out with the idea to analyze the antioxidants contains in leaves of the plant by undergoes different extraction and chemical testing method. The phytochemical screening assay involved in this study are antioxidant activity by using free radical diphenylpicrylhydrazyl (DPPH) method, total phenolic content by using Folin-Ciocalteu method, total flavonoid content by using colorimetric assay with ascorbic acid and quercetin were used as reference standards while for phosphorus analysis, a molybdenum blue method or also known as ascorbic acid method was used. For antioxidant activity by using free radical diphenylpicrylhydrazyl (DPPH) method, higher concentration was recorded by extraction using methanol (dried sample) which is 8247.0 mg/L, for total phenolic content higher concentration was recorded by extraction using deionized water (dried sample) which is 4276.0 mg/L, for total flavonoid content by using colorimetric assay higher concentration was recorded by extraction using methanol (dried sample) which is 4439.0 mg/L, and for for phosphorus analysis higher concentration was recorded by extraction using methanol (dried sample) which is 71.057 mg/L.
Single-snapshot 2D color measurement by plenoptic imaging system
NASA Astrophysics Data System (ADS)
Masuda, Kensuke; Yamanaka, Yuji; Maruyama, Go; Nagai, Sho; Hirai, Hideaki; Meng, Lingfei; Tosic, Ivana
2014-03-01
Plenoptic cameras enable capture of directional light ray information, thus allowing applications such as digital refocusing, depth estimation, or multiband imaging. One of the most common plenoptic camera architectures contains a microlens array at the conventional image plane and a sensor at the back focal plane of the microlens array. We leverage the multiband imaging (MBI) function of this camera and develop a single-snapshot, single-sensor high color fidelity camera. Our camera is based on a plenoptic system with XYZ filters inserted in the pupil plane of the main lens. To achieve high color measurement precision of this system, we perform an end-to-end optimization of the system model that includes light source information, object information, optical system information, plenoptic image processing and color estimation processing. Optimized system characteristics are exploited to build an XYZ plenoptic colorimetric camera prototype that achieves high color measurement precision. We describe an application of our colorimetric camera to color shading evaluation of display and show that it achieves color accuracy of ΔE<0.01.
A new diatom growth inhibition assay using the XTT colorimetric method.
Jiang, Weina; Akagi, Takuya; Suzuki, Hidekazu; Takimoto, Ayaka; Nagai, Hiroshi
2016-01-01
Marine biofouling, which leads to significant operational stress and economic damage on marine infrastructures, is a major problem in marine related industries. Currently, the most common way to avoid marine biofouling involves the use of biocidal products in surface coatings. However, the need for environmentally friendly antibiofouling compounds has increased rapidly with the recent global prohibition of harmful antifoulants, such as tributyltin (TBT). In particular, periphytic diatoms have been shown to contribute significantly to biofilms, which play an important role in biofouling. Therefore, inhibiting the proliferation of fouling diatoms is a very important step in the prevention of marine biofouling. In this study, we developed a new, rapid, accurate, and convenient growth inhibition assay using the XTT colorimetric method to prevent the growth of the fouling periphytic diatom, Nitzschia amabilis Hidek. Suzuki (replaced synonym, Nitzschia laevis Hustedt). The feasibility of this method was verified by determining the growth inhibition activities of two standard photosynthetic inhibitors, DCMU and CuSO4. However, neither inhibitor had any cytotoxic activities at the range of concentrations tested. Moreover, this method was applied by screening and purification of herbicidic but non-cytotoxic compounds from cyanobacteria extracts. Our results demonstrate the utility of this newly established growth inhibition assay for the identification of marine anti-biofouling compounds. Copyright © 2016 Elsevier Inc. All rights reserved.
Nzelu, Chukwunonso O; Gomez, Eduardo A; Cáceres, Abraham G; Sakurai, Tatsuya; Martini-Robles, Luiggi; Uezato, Hiroshi; Mimori, Tatsuyuki; Katakura, Ken; Hashiguchi, Yoshihisa; Kato, Hirotomo
2014-04-01
Entomological monitoring of Leishmania infection in leishmaniasis endemic areas offers epidemiologic advantages for predicting the risk and expansion of the disease, as well as evaluation of the effectiveness of control programs. In this study, we developed a highly sensitive loop-mediated isothermal amplification (LAMP) method for the mass screening of sand flies for Leishmania infection based on the 18S rRNA gene. The LAMP technique could detect 0.01 parasites, which was more sensitive than classical PCR. The method was robust and could amplify the target DNA within 1h from a crude sand fly template without DNA purification. Amplicon detection could be accomplished by the newly developed colorimetric malachite green (MG)--mediated naked eye visualization. Pre-addition of MG to the LAMP reaction solution did not inhibit amplification efficiency. The field applicability of the colorimetric MG-based LAMP assay was demonstrated with 397 field-caught samples from the endemic areas of Ecuador and eight positive sand flies were detected. The robustness, superior sensitivity, and ability to produce better visual discriminatory reaction products than existing LAMP fluorescence and turbidity assays indicated the field potential usefulness of this new method for surveillance and epidemiological studies of leishmaniasis in developing countries. Copyright © 2013 Elsevier B.V. All rights reserved.
Drinking water ozone disinfection systems measure ozone residual concentration, C, for regulatory compliance reporting of concentration-times-time (CT), and the resultant log-inactivation of virus, Giardia and Cryptosporidium. The indigotrisulfonate (ITS) colorimetric procedure i...
NASA Astrophysics Data System (ADS)
Kandi, Saeideh Gorji; Nourmohammadian, Farahnaz
2013-10-01
In the present study, colorimetric characteristics of six photochromic bis-azospiropyrans based dyes are investigated. The colorimetric axes of these dyes in terms of hue, chroma and lightness are considered via UV exposure time. Results showed that, the hue angle of these dyes changes rapidly at the first times of UV irradiation, and then remains almost constant. However, chroma and lightness continuously change till about 80-240 s for different dyes. In addition, it is shown that variations of lightness and chroma by UV exposure time have an exponential trend, which can be modeled mathematically.
USDA-ARS?s Scientific Manuscript database
Starch, glycogen, maltooligosaccharides, and other alpha-1,4- and alpha-1,6-linked glucose carbohydrates exclusive of resistant starch are collectively termed "dietary starch." This nutritionally important fraction is increasingly measured for use in diet formulation for animals, as it can have posi...
USDA-ARS?s Scientific Manuscript database
Accurate and rapid assays for glucose are desirable for analysis of glucose and starch in food and feedstuffs. An established colorimetric glucose oxidase-peroxidase method for glucose was modified to reduce analysis time, and evaluated for factors that affected accuracy. Time required to perform t...
USDA-ARS?s Scientific Manuscript database
Aims: To design and validate a colorimetric loop-mediated isothermal amplification assay for rapid detection of P. infestans DNA. Methods and Results: Two sets of LAMP primers were designed and evaluated for their sensitivity and specificity for P. infestans. ITSII primers targeted a portion of the ...
Colorimetric Detection of Water Vapor Using Metal-Organic Framework Composites.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Allendorf, Mark D.
Purpose: Water vapor trapped in encapsulation materials or enclosed volumes leads to corrosion issues for critical NW components. Sandia National Laboratories has created a new diagnostic to indicate the presence of water in weapon systems. Impact: Component exposure to water now can be determined instantly, without need for costly, time-consuming analytical methods.
USDA-ARS?s Scientific Manuscript database
Phosphatidate phosphatase (3-sn-phosphatidate phosphohydrolase, EC 3.1.3.4), which is also known as PAP, catalyzes the dephosphorylation of phosphatidate (PtdOH) to form diacylglycerol (DAG) and inorganic phosphate. In eukaryotes, PAP driven reaction is the committed step in the synthesis of triacyl...
The purpose of this SOP is to describe the methodology used by Air Quality Research (Research Triangle Park, NC) for the analysis of the PF-1 passive formaldehyde samplers using a colorimetric method and chromotropic acid. This procedure was followed to ensure consistent data re...
Quercetin as colorimetric reagent for determination of zirconium
Grimaldi, F.S.; White, C.E.
1953-01-01
Methods described in the literature for the determination of zirconium are generally designed for relatively large amounts of this element. A good procedure using colorimetric reagent for the determination of trace amounts is desirable. Quercetin has been found to yield a sensitive color reaction with zirconium suitable for the determination of from 0.1 to 50?? of zirconium dioxide. The procedure developed involves the separation of zirconium from interfering elements by precipitation with p-dimethylaminoazophenylarsonic acid prior to its estimation with quercetin. The quercetin reaction is carried out in 0.5N hydrochloric acid solution. Under the operating conditions it is indicated that quercetin forms a 2 to 1 complex with zirconium; however, a 2 to 1 and a 1 to 1 complex can coexist under special conditions. Approximate values for the equilibrium constants of the complexes are K1 = 0.33 ?? 10-5 and K2 = 1.3 ?? 10-9. Seven Bureau of Standards samples of glass sands and refractories were analyzed with excellent results. The method described should find considerable application in the analysis of minerals and other materials for macro as well as micro amounts of zirconium.
Guo, Zhiyong; Jia, Yaru; Song, Xinxin; Lu, Jing; Lu, Xuefei; Liu, Baoqing; Han, Jiaojiao; Huang, Youju; Zhang, Jiawei; Chen, Tao
2018-05-15
Conventional methods for the detection of Vibrio parahemolyticus (VP) usually need tedious, labor-intensive processes, and have low sensitivity, which further limits their practical applications. Herein, we developed a simple and efficient colorimetry and surface-enhanced Raman scattering (SERS) dual-mode immunosensor for sensitive detection of VP, by employing giant Au vesicles with anchored tiny gold nanowires (AuNW) as a smart probe. Due to the larger specific surface and special hollow structure of giant Au vesicles, silver staining would easily lead to vivid color change for colorimetric analysis and further amplify SERS signals. The t-test was further used to determine if two sets of data from colorimetry and SERS were significantly different from each other. The result shows that there was no significant difference between data from the two methods. Two sets of data can mutually validate each other and avoid false positive and negative detection. The designed colorimetry-SERS dual-mode sensor would be very promising in various applications such as food safety inspection, personal healthcare, and on-site environmental monitoring.
NASA Technical Reports Server (NTRS)
Hazen-Bosveld, April; Lipert, Robert J.; Nordling, John; Shih, Chien-Ju; Siperko, Lorraine; Porter, Marc D.; Gazda, Daniel B.; Rutz, Jeff A.; Straub, John E.; Schultz, John R.;
2007-01-01
Colorimetric-solid phase extraction (C-SPE) is being developed as a method for in-flight monitoring of spacecraft water quality. C-SPE is based on measuring the change in the diffuse reflectance spectrum of indicator disks following exposure to a water sample. Previous microgravity testing has shown that air bubbles suspended in water samples can cause uncertainty in the volume of liquid passed through the disks, leading to errors in the determination of water quality parameter concentrations. We report here the results of a recent series of C-9 microgravity experiments designed to evaluate manual manipulation as a means to collect bubble-free water samples of specified volumes from water sample bags containing up to 47% air. The effectiveness of manual manipulation was verified by comparing the results from C-SPE analyses of silver(I) and iodine performed in-flight using samples collected and debubbled in microgravity to those performed on-ground using bubble-free samples. The ground and flight results showed excellent agreement, demonstrating that manual manipulation is an effective means for collecting bubble-free water samples in microgravity.
An instrument-free, screen-printed paper microfluidic device that enables bio and chemical sensing.
Mohammadi, Saeed; Maeki, Masatoshi; Mohamadi, Reza M; Ishida, Akihiko; Tani, Hirofumi; Tokeshi, Manabu
2015-10-07
This paper describes a simple and instrument-free screen-printing method to fabricate hydrophilic channels by patterning polydimethylsiloxane (PDMS) onto chromatography paper. Clearly recognizable border lines were formed between hydrophilic and hydrophobic areas. The minimum width of the printed channel to deliver an aqueous sample was 600 μm, as obtained by this method. Fabricated microfluidic paper-based analytical devices (μPADs) were tested for several colorimetric assays of pH, glucose, and protein in both buffer and artificial urine samples and results were obtained in less than 30 min. The limits of detection (LODs) for glucose and bovine serum albumin (BSA) were 5 mM and 8 μM, respectively. Furthermore, the pH values of different solutions were visually recognised with the naked eye by using a sensitive ink. Ultimately, it is expected that this PDMS-screen-printing (PSP) methodology for μPADs can be readily translated to other colorimetric detection and hydrophilic channels surrounded by a hydrophobic polymer can be formed to transport fluids toward target zones.
Ding, Nan; Cao, Qian; Zhao, Hong; Yang, Yimin; Zeng, Lixi; He, Yujian; Xiang, Kaixiang; Wang, Guangwei
2010-01-01
In this report, we present a new method for visual detection of Pb2+. Gold nanoparticles (Au-NPs) were synthesized in one step at room temperature, using gallic acid (GA) as reducer and stabilizer. Pb2+ is added during the gold nanoparticle formation. Analysis of Pb2+ is conducted by a dual strategy, namely, colorimetry and spectrometry. During Au-NPs synthesis, addition of Pb2+ would lead to formation of Pb-GA complex, which can induce the aggregation of newly-formed small unstable gold nanoclusters. Consequently, colorimetric detection of trace Pb2+ can be realized. As the Pb2+ concentration increases, the color turns from red-wine to purple, and finally blue. This method offers a sensitive linear correlation between the shift of the absorption band (Δλ) and logarithm of Pb2+ concentration ranging from 5.0 × 10−8 to 1.0 × 10−6 M with a linear fit coefficient of 0.998, and a high selectivity for Pb2+ detection with a low detection limit down to 2.5 × 10−8 M. PMID:22163517
The Biological Effect of the NanoTiO
Xiao-Feng, Pang; Lewei, Liu; Zhi Hong, Liu; Qiang, Zhao
2005-01-01
The proliferation behavior of the person's liver cell under actions of the nanoTiO
Huang, Zhenzhen; Wang, Haonan; Yang, Wensheng
2015-05-06
In this work, a facile colorimetric method is developed for quantitative detection of human serum albumin (HSA) based on the antiaggregation effect of gold nanoparticles (Au NPs) in the presence of HSA. The citrate-capped Au NPs undergo a color change from red to blue when melamine is added as a cross-linker to induce the aggregation of the NPs. Such an aggregation is efficiently suppressed upon the adsorption of HSA on the particle surface. This method provides the advantages of simplicity and cost-efficiency for quantitative detection of HSA with a detection limit of ∼1.4 nM by monitoring the colorimetric changes of the Au NPs with UV-vis spectroscopy. In addition, this approach shows good selectivity for HSA over various amino acids, peptides, and proteins and is qualified for detection of HSA in a biological sample. Such an antiaggregation effect can be further extended to fabricate an INHIBIT logic gate by using HSA and melamine as inputs and the color changes of Au NPs as outputs, which may have application potentials in point-of-care medical diagnosis.
Le, Chencheng; Stuckey, David C
2016-05-01
Four laboratory preparations and three commercially available assay kits were tested on the same carbohydrate samples with the addition of 14 different interfering solutes typically found in wastewater treatment plants. This work shows that a wide variety of solutes can interfere with these assays. In addition, a comparative study on the use of these assays with different carbohydrate samples was also carried out, and the metachromatic response was clearly influenced by variation in sample composition. The carbohydrate content in the supernatant of a submerged anaerobic membrane bioreactor (SAMBR) was also measured using these assays, and the amount in the different supernatant samples, with and without a standard addition of glucose to the samples, showed substantial differences. We concluded that the carbohydrates present in wastewater measured using these colorimetric methods could be seriously under- or over-estimated. A new analytical method needs to be developed in order to better understand the biological transformations occurring in anaerobic digestion that leads to the production of soluble microbial products (SMPs) and extracellular polymeric substance (EPS). Copyright © 2016 Elsevier Ltd. All rights reserved.
Colorimetric detection of cholesterol based on enzyme modified gold nanoparticles
NASA Astrophysics Data System (ADS)
Nirala, Narsingh R.; Saxena, Preeti S.; Srivastava, Anchal
2018-02-01
We develop a simple colorimetric method for determination of free cholesterol in aqueous solution based on functionalized gold nanoparticles with cholesterol oxidase. Functionalized gold nanoparticles interact with free cholesterol to produce H2O2 in proportion to the level of cholesterol visually is being detected. The quenching in optical properties and agglomeration of functionalized gold nanoparticles play a key role in cholesterol sensing due to the electron accepting property of H2O2. While the lower ranges of cholesterol (lower detection limit i.e. 0.2 mg/dL) can be effectively detected using fluorescence study, the absorption study attests evident visual color change which becomes effective for detection of higher ranges of cholesterol (lower detection limit i.e. 19 mg/dL). The shades of red gradually change to blue/purple as the level of cholesterol detected (as evident at 100 mg/dL) using unaided eye without the use of expensive instruments. The potential of the proposed method to be applied in the field is shown by the proposed cholesterol measuring color wheel.
Huber, Charlotte A; Sidjabat, Hanna E; Zowawi, Hosam M; Kvaskoff, David; Reed, Sarah; McNamara, John F; McCarthy, Kate L; Harris, Patrick; Toh, Benjamin; Wailan, Alexander M; Paterson, David L
2016-12-01
It has been described that the sensitivity of the Carba NP test may be low in the case of OXA-48-like carbapenamases and mass spectrometry based methods as well as a colorimetry based method have been described as alternatives. We evaluated 84 Enterobacteriaceae isolates including 31 OXA-48-like producing isolates and 13 isolates that produced either an imipenemase (IMP; n=8), New Delhi metallo-β-lactamase (NDM; n=3), or Klebsiella pneumoniae carbapenemase (KPC; n=2), as well as 40 carbapenemase negative Enterobacteriaceae isolates. We used the Neo-Rapid CARB kit, assessing the results with the unaided eye and compared it with a colorimetric approach. Furthermore, we incubated the isolates in growth media with meropenem and measured the remaining meropenem after one and 2h of incubation, respectively, using liquid chromatography tandem mass spectrometry (LC-MS/MS). Whilst all carbapenemase producing isolates with the exception of the OXA-244 producer tested positive for both the Neo-rapid CARB test using the unaided eye or colorimetry, and the 13 isolates producing either IMP, NDM or KPC hydrolysed the meropenem in the media almost completely after 2h of incubation, the 31 OXA-48-like producing isolates exhibited very variable hydrolytic activity when incubated in growth media with meropenem. In our study, the Neo-Rapid CARB test yielded a sensitivity of 98% for both the traditional and the colorimetric approach with a specificity of 95% and 100% respectively. Our results indicate that the Neo-Rapid CARB test may have use for the detection of OXA-48 type carbapenemases and that it may be particularly important to ensure bacterial lysis for the detection of these weaker hydrolysers. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.
Pivetal, Jeremy; Pereira, Filipa M; Barbosa, Ana I; Castanheira, Ana P; Reis, Nuno M; Edwards, Alexander D
2017-03-13
This study reports for the first time the sensitive colorimetric and fluorescence detection of clinically relevant protein biomarkers by sandwich immunoassays using the covalent immobilisation of antibodies onto the fluoropolymer surface inside Teflon®-FEP microfluidic devices. Teflon®-FEP has outstanding optical transparency ideal for high-sensitivity colorimetric and fluorescence bioassays, however this thermoplastic is regarded as chemically inert and very hydrophobic. Covalent immobilisation can offer benefits over passive adsorption to plastic surfaces by allowing better control over antibody density, orientation and analyte binding capacity, and so we tested a range of different and novel covalent immobilisation strategies. We first functionalised the inner surface of a 10-bore, 200 μm internal diameter FEP microcapillary film with high-molecular weight polyvinyl alcohol (PVOH) without changing the outstanding optical transparency of the device delivered by the matched refractive index of FEP and water. Glutaraldehyde immobilisation was compared with the use of photoactivated linkers and NHS-ester crosslinkers for covalently immobilising capture antibodies onto PVOH. Three clinically relevant sandwich ELISAs were tested against the cytokine IL-1β, the myocardial infarct marker cardiac troponin I (cTnI), and the chronic heart failure marker brain natriuretic peptide (BNP). Overall, glutaraldehyde immobilisation was effective for BNP assays, but yielded unacceptable background for IL-1β and cTnI assays caused by direct binding of the biotinylated detection antibody to the modified PVOH surface. We found NHS-ester groups reacted with APTES-treated PVOH coated fluoropolymers. This facilitated a novel method for capture antibody immobilisation onto fluoropolymer devices using a bifunctional NHS-maleimide crosslinker. The density of covalently immobilised capture antibodies achieved using PVOH/APTES/NHS/maleimide approached levels seen with passive adsorption, and sensitive and quantitative assay performance was achieved using this method. Overall, the PVOH coating provided an excellent surface for controlled covalent antibody immobilisation onto Teflon®-FEP for performing high-sensitivity immunoassays.
Choleva, Tatiana G; Gatselou, Vasiliki A; Tsogas, George Z; Giokas, Dimosthenis L
2017-12-05
The intrinsic peroxidase-like activity of rhodium nanoparticles (RhNPs) and their use as catalytic labels for sensitive colorimetric assays is presented. RhNPs catalyze the oxidation of the peroxidase substrate 3,3,5,5-tetramethylbenzidine (TMB) in the presence of H 2 O 2 to produce a blue reaction product with a maximum absorbance at 652 nm. Kinetic studies show catalysis to follow Michaelis-Menten kinetics and a "ping-pong" mechanism. The calculated kinetic parameters indicate high affinity of RhNPs for both the substrate TMB and H 2 O 2 . In fact, they are better than other peroxidase mimicking nanomaterials and even the natural enzyme horseradish peroxidase. On the other hand, RhNPs exhibit no reactivity towards saccharides, thiols, amino acids and ascorbic acid. Based on these findings, a sensitive and selective colorimetric method was worked out for the determination of H 2 O 2 in real samples with a linear response in the 1-100 μM concentration range. By employing glucose oxidase, the glucose assay has a linear range that covers the 5 to 125 μM glucose concentration range. The detection limits are <0.75 μM for both species. The methods were applied to the determination of H 2 O 2 in spiked pharmaceutical formulations, and of glucose in soft drinks and blood plasma. Figures of merit include (a) good accuracy (with errors of <6%), (b) high recoveries (96.5-103.7%), and (c) satisfactory reproducibility (<6.3%). Graphical abstract Rhodium nanoparticles catalyze the oxidation of 3,3,5,5-tetramethylbenzidine (TMB) in the presence of H 2 O 2 to produce a blue reaction product. The effect is exploited in photometric assays for hydrogen peroxide and glucose.
Wang, Xu; Li, Fang; Cai, Ziqi; Liu, Kaifan; Li, Jing; Zhang, Boyang; He, Jianbo
2018-04-01
In this work, a multilayer-modified paper-based colorimetric sensing platform with improved color uniformity and intensity was developed for the sensitive and selective determination of uric acid and glucose with smartphone as signal readout. In detail, chitosan, different kinds of chromogenic reagents, and horseradish peroxidase (HRP) combined with a specific oxidase, e.g., uricase or glucose oxidase (GOD), were immoblized onto the paper substrate to form a multilayer-modified test paper. Hydrogen peroxide produced by the oxidases (uricase or GOD) reacts with the substrates (uric acid or glucose), and could oxidize the co-immoblized chromogenic reagents to form colored products with HRP as catalyst. A simple strategy by placing the test paper on top of a light-emitting diode lamp was adopted to efficiently prevent influence from the external light. The color images were recorded by the smartphone camera, and then the gray values of the color images were calculated for quantitative analysis. The developed method provided a wide linear response from 0.01 to 1.0 mM for uric acid detection and from 0.02 to 4.0 mM for glucose detection, with a limit of detection (LOD) as low as 0.003 and 0.014 mM, respectively, which was much lower than for previously reported paper-based colorimetric assays. The proposed assays were successfully applied to uric acid and glucose detection in real serum samples. Furthermore, the enhanced analytical performance of the proposed method allowed the non-invasive detection of glucose levels in tear samples, which holds great potential for point-of-care analysis. Graphical abstract ᅟ.
Wang, Yanying; Liu, Yaqin; Ding, Fang; Zhu, Xiaoyan; Yang, Li; Zou, Ping; Rao, Hanbing; Zhao, Qingbiao; Wang, Xianxiang
2018-06-07
In this study, we developed a simple colorimetric approach to detect glutathione (GSH). The proposed approach is based on the ability of CuS-PDA-Au composite material to catalytically oxidize 3,3',5,5'-tetramethylbenzidine (TMB) to ox-TMB to induce a blue color with an absorption peak centered at 652 nm. However, the introduction of GSH can result in a decrease in oxidized TMB; similarly, it can combine with Au nanoparticles (Au NPs) on the surface of CuS-PDA-Au composite material. Both approaches can result in a fading blue color and a reduction of the absorbance at 652 nm. Based on this above, we proposed a technique to detect GSH quantitatively and qualitatively through UV-Vis spectroscopy and naked eye, respectively. This approach demonstrates a low detection limit of 0.42 μM with a broad detection range of 5 × 10 -7 -1 × 10 -4 M with the assistance of UV-Vis spectroscopy. More importantly, this approach is convenient and rapid. This method was successfully applied to GSH detection in human serum and cell lines. Graphical abstract A colorimetric approach has been developed by exploiting the peroxidase-like activity of CuS-polydopamine-Au composite for sensitive glutathione detection.
Ozdemir Olgun, F Ayca; Üzer, Ayşem; Ozturk, Birsen Demirata; Apak, Reşat
2018-05-15
Antioxidant activity (AOA) assays using nanotechnology are recently developed utilizing nanoparticles of transition metal oxides, especially nanoceria that can switch between trivalent and tetravalent oxidation states of cerium. Cerium oxide nanoparticles (CeO-NPs) may act as both an oxidant and an antioxidant, depending on the preparation method and particle size. A novel colorimetric sensor for AOA assay is proposed with the use of poly(acrylic acid) sodium salt (PAANa)-coated CeO-NPs. PAANa-coated CeO-NPs oxidized tetramethyl benzidine (TMB), a peroxidase substrate, in a slightly acidic solution at pH 4.0 to a blue charge-transfer complex. Antioxidants decreased the color intensity of the nanoceria suspension, and were indirectly determined by absorbance difference. Detection limits, linearity, additivity and precision were calculated, e.g., quercetin quantification with the proposed assay showed a detection limit of 8.25 × 10 -9 mol L -1 . The trolox equivalent antioxidant capacities of hydrophilic and lipophilic antioxidants were compatible with those of conventional antioxidant assays. Potential interferents such as glucose, citric acid, mannitol, sorbitol and benzoic acid did not adversely affect AOA determination. The developed sensor is more sensitive and selective than similar colorimetric sensors relying on the intrinsic color change of nanoceria. The measurement wavelength is sufficiently red-shifted, preventing possible interferences from plant pigments. Copyright © 2018 Elsevier B.V. All rights reserved.
Portable device for the detection of colorimetric assays
Nowak, E.; Kawchuk, J.; Hoorfar, M.; Najjaran, H.
2017-01-01
In this work, a low-cost, portable device is developed to detect colorimetric assays for in-field and point-of-care (POC) analysis. The device can rapidly detect both pH values and nitrite concentrations of five different samples, simultaneously. After mixing samples with specific reagents, a high-resolution digital camera collects a picture of the sample, and a single-board computer processes the image in real time to identify the hue–saturation–value coordinates of the image. An internal light source reduces the effect of any ambient light so the device can accurately determine the corresponding pH values or nitrite concentrations. The device was purposefully designed to be low-cost, yet versatile, and the accuracy of the results have been compared to those from a conventional method. The results obtained for pH values have a mean standard deviation of 0.03 and a correlation coefficient R2 of 0.998. The detection of nitrites is between concentrations of 0.4–1.6 mg l−1, with a low detection limit of 0.2 mg l−1, and has a mean standard deviation of 0.073 and an R2 value of 0.999. The results represent great potential of the proposed portable device as an excellent analytical tool for POC colorimetric analysis and offer broad accessibility in resource-limited settings. PMID:29291093
Zhong, Xianhua; Li, Dan; Du, Wei; Yan, Mengqiu; Wang, You; Huo, Danqun; Hou, Changjun
2018-06-01
Volatile organic compounds (VOCs) in breath can be used as biomarkers to identify early stages of lung cancer. Herein, we report a disposable colorimetric array that has been constructed from diverse chemo-responsive colorants. Distinguishable difference maps were plotted within 4 min for specifically targeted VOCs. Through the consideration of various chemical interactions with VOCs, the arrays successfully discriminate between 20 different volatile organic compounds in breath that are related to lung cancer. VOCs were identified either with the visualized difference maps or through pattern recognition with an accuracy of at least 90%. No uncertainties or errors were observed in the hierarchical cluster analysis (HCA). Finally, good reproducibility and stability of the array was achieved against changes in humidity. Generally, this work provides fundamental support for construction of simple and rapid VOC sensors. More importantly, this approach provides a hypothesis-free array method for breath testing via VOC profiling. Therefore, this small, rapid, non-invasive, inexpensive, and visualized sensor array is a powerful and promising tool for early screening of lung cancer. Graphical abstract A disposable colorimetric array has been developed with broadly chemo-responsive dyes to incorporate various chemical interactions, through which the arrays successfully discriminate 20 VOCs that are related to lung cancer via difference maps alone or chemometrics within 4 min. The hydrophobic porous matrix provides good stability against changes in humidity.
Determination of ferrous and total iron in refractory spinels
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amonette, James E.; Matyas, Josef
2015-12-30
Accurate and precise determination of the redox state of iron (Fe) in spinels presents a significant challenge due to their refractory nature. The resultant extreme conditions needed to obtain complete dissolution generally oxidize some of the Fe(II) initially present and thus prevent the use of colorimetric methods for Fe(II) measurements. To overcome this challenge we developed a hybrid oxidimetric/colorimetric approach, using Ag(I) as the oxidimetric reagent for determination of Fe(II) and 1,10-phenanthroline as the colorimetric reagent for determination of total Fe. This approach, which allows determination of Fe(II) and total Fe on the same sample, was tested on a seriesmore » of four geochemical reference materials and then applied to the analysis of Fe(Ni) spinel crystals isolated from simulated high-level-waste (HLW) glass and of several reagent magnetites. Results for the reference materials were in excellent agreement with published values, with the exception of USGS BIR-1, for which higher Fe(II) values and lower total Fe values were obtained. The Fe(Ni) spinels showed Fe(II) values at the detection limit (ca. 0.05 wt% Fe) and total Fe values slightly higher than obtained by total elemental analysis. For the magnetite samples, total Fe values were in agreement with reference results, but a wide range in Fe(II) values was obtained indicating various degrees of conversion to maghemite.« less
Chromium(VI) release from leather and metals can be detected with a diphenylcarbazide spot test.
Bregnbak, David; Johansen, Jeanne D; Jellesen, Morten S; Zachariae, Claus; Thyssen, Jacob P
2015-11-01
Along with chromium, nickel and cobalt are the clinically most important metal allergens. However, unlike for nickel and cobalt, there is no validated colorimetric spot test that detects chromium. Such a test could help both clinicians and their patients with chromium dermatitis to identify culprit exposures. To evaluate the use of diphenylcarbazide (DPC) as a spot test reagent for the identification of chromium(VI) release. A colorimetric chromium(VI) spot test based on DPC was prepared and used on different items from small market surveys. The DPC spot test was able to identify chromium(VI) release at 0.5 ppm without interference from other pure metals, alloys, or leather. A market survey using the test showed no chromium(VI) release from work tools (0/100). However, chromium(VI) release from metal screws (7/60), one earring (1/50), leather shoes (4/100) and leather gloves (6/11) was observed. We found no false-positive test reactions. Confirmatory testing was performed with X-ray fluorescence (XRF) and spectrophotometrically on extraction fluids. The use of DPC as a colorimetric spot test reagent appears to be a good and valid test method for detecting the release of chromium(VI) ions from leather and metal articles. The spot test has the potential to become a valuable screening tool. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
Colorimetric detection of biothiols based on aggregation of chitosan-stabilized silver nanoparticles
NASA Astrophysics Data System (ADS)
Mohammadi, Somayeh; Khayatian, Gholamreza
2017-10-01
We have described a simple and reliable colorimetric method for the sensing of biothiols such as cysteine, homocysteine, and glutathione in biological samples. The selective binding of chitosan capped silver nanoparticles to biothiols induced aggregation of the chitosan-Ag NPs. But the other amino acids that do not have thiol group cannot aggregate the chitosan-Ag NPs. Aggregation of chitosan-Ag NPs has been confirmed with UV-vis absorption spectra, zeta potential and transmission electron microscopy images. Under optimum conditions, good linear relationships existed between the absorption ratios (at A500/A415) and the concentrations of cysteine, homocysteine, and glutathione in the range of 0.1-10.0 μM with detection limits of 15.0, 84.6 and 40.0 nM, respectively. This probe was successfully applied to detect these biothiols in biological samples (urine and plasma).
Detection of Carbendazim Residues with a Colorimetric Sensor Based on Gold Nanoparticles
NASA Astrophysics Data System (ADS)
Ma, Y.; Jiang, H.; Shen, C.; Hou, Ch.; Huo, D.; Wu, H.; Yang, M.
2017-07-01
Carbendazim is among the most popular benzimidazole bactericides that are widely used to boost food production, and its residue poses a great threat to human health and the environment. In this paper, we presented a colorimetric sensor based on gold nanoparticles (Au-NPs) for the detection of carbendazim residues. The Au-NPs were stabilized by citric acid synthesized by chloroauric acid and sodium citrate with a diameter of about 13 nm. Upon reaction with carbendazim, the sensor gave a clear color change that could be distinguished with the naked eye. Thus we elaborated a new method for rapid determination of this benzimidazole bactericide. After optimization of the detection conditions, the sensor showed a very good linear relationship with the carbendazim concentrations varying from 10 to 600 ppb with a detection limit down to 3.4 ppb (S/N = 3). These preliminary results demonstrate that the presented sensor is promising for fast carbendazim analysis.
Kynetic resazurin assay (KRA) for bacterial quantification of foodborne pathogens
NASA Astrophysics Data System (ADS)
Arenas, Yaxal; Mandel, Arkady; Lilge, Lothar
2012-03-01
Fast detection of bacterial concentrations is important for the food industry and for healthcare. Early detection of infections and appropriate treatment is essential since, the delay of treatments for bacterial infections tends to be associated with higher mortality rates. In the food industry and in healthcare, standard procedures require the count of colony-forming units in order to quantify bacterial concentrations, however, this method is time consuming and reports require three days to be completed. An alternative is metabolic-colorimetric assays which provide time efficient in vitro bacterial concentrations. A colorimetric assay based on Resazurin was developed as a time kinetic assay (KRA) suitable for bacterial concentration measurements. An optimization was performed by finding excitation and emission wavelengths for fluorescent acquisition. A comparison of two non-related bacteria, foodborne pathogens Escherichia coli and Listeria monocytogenes, was performed in 96 well plates. A metabolic and clonogenic dependence was established for fluorescent kinetic signals.
Colorimetric detection of glucose based on gold nanoparticles coupled with silver nanoparticles
NASA Astrophysics Data System (ADS)
Gao, Yan; Wu, Yiting; Di, Junwei
2017-02-01
We have coupled gold nanoparticles (AuNPs) with silver nanoparticles (AgNPs) to assemble a plasmonic sensing platform for colorimetric detection of glucose. In this system, small AuNPs ( 4 nm) can act as glucose oxidase (GOD) mimic enzyme to catalytically oxidize glucose in the presence of oxygen, producing hydrogen peroxide, which dissolves AgNPs to lead the color changes. Glucose can be detected not only by naked eyes (from yellow to red) but also by spectrophotometer in the concentration range of 5-70 μM, with detection limit of 3 μM. More importantly, we found that L-cysteine added in the system can markedly improve the selectivity for the detection of glucose. The proposed method was used to application for the detection of glucose in human serum with satisfactory results. This system is simple and low cost without using any enzymes and organic chromogenic agents.
A colorimetric and fluorogenic probe for bisulfite using benzopyrylium as the recognition unit.
Zhang, Yun; Zhang, Xiangwen; Yang, Xiao-Feng; Zhang, Juan
2017-11-01
A coumarin-benzopyrylium (CB) platform has been developed for the colorimetric and fluorogenic detection of bisulfite. The proposed probe utilizes coumarin as the fluorophore and positively charged benzopyrylium as the reaction site. The method employs the nucleophilic addition of bisulfite to the benzopyrylium moiety of CB to inactivate the electron-deficient oxonium ion. The driving force for photo-induced electron transfer is considerably diminished, thereby promoting the emission intensity of the coumarin fluorophore. The fluorescence intensity at 510 nm is linear with bisulfite concentration over a range of 0.2-7.5 μM with a detection limit of 42 nM (3δ). CB shows a rapid response (within 30 s) and high selectivity and sensitivity for bisulfite. Preliminary studies show that CB has great potential for bisulfite detection in real samples and in living cells. Copyright © 2017 John Wiley & Sons, Ltd.
Tsai, Wei-Kai; Lai, Yung-Sheng; Tseng, Po-Jung; Liao, Chia-Hsien; Chan, Yang-Hsiang
2017-09-13
Semiconducting polymer dots (Pdots) have recently emerged as a novel type of ultrabright fluorescent probes that can be widely used in analytical sensing and material science. Here, we developed a dual visual reagent based on Pdots for anticounterfeiting applications. We first designed and synthesized two types of photoswitchable Pdots by incorporating photochromic dyes with multicolor semiconducting polymers to modulate their emission intensities and wavelengths. The resulting full-color Pdot assays showed that the colorimetric and fluorescent dual-readout abilities enabled the Pdots to serve as an anticounterfeiting reagent with low background interference. We also doped these Pdots into flexible substrates and prepared these Pdots as inks for pen handwriting as well as inkjet printing. We further applied this reagent in printing paper and checks for high-security anticounterfeiting purposes. We believe that this dual-readout method based on Pdots will create a new avenue for developing new generations of anticounterfeiting technologies.
Wu, Juanjuan; Ye, Zhuo; Wu, Feng; Wang, Hongying; Zeng, Lintao; Bao, Guang-Ming
2018-05-01
Thiophenols are a class of highly toxic environmental pollutant, hence it is very necessary to monitor thiophenols in environment and living cells with an efficient and reliable method. Herein, a novel fluorescent probe for thiophenols has been developed, which exhibited a colorimetric and fluorescence turn-on dual response towards thiophenols with good selectivity and fast response. The sensing mechanism for thiophenols was attributed to nucleophilic substitution reaction, which was confirmed by HPLC. The probe exhibited good recovery (from 90% to 107%) and low limit of detection for thiophenols (37nM) in industrial wastewater. Moreover, the probe has been successfully employed to visualize thiophenol in living cells. Therefore, the fluorescent probe has good capability for monitoring thiophenols in environmental samples and biological systems. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Technical Reports Server (NTRS)
Lipert, Robert J.; Porter, Marc D.; Siperko, Lorraine M.; Gazda, Daniel B.; Rutz, Jeff A.; Schultz, John R.; Carrizales, Stephanie M.; McCoy, J. Torin
2009-01-01
An experimental drinking water monitoring kit for the measurement of iodine and silver(I) was recently delivered to the International Space Station (ISS). The kit is based on Colorimetric Solid Phase Extraction (CSPE) technology, which measures the change in diffuse reflectance of indicator disks following exposure to a water sample. To satisfy additional spacecraft water monitoring requirements, CSPE has now been extended to encompass the measurement of total I (iodine, iodide, and triiodide) through the introduction of an oxidizing agent, which converts iodide and triiodide to iodine, for measurement using the same indicator disks currently being tested on ISS. These disks detect iodine, but are insensitive to iodide and triiodide. We report here the operational considerations, design, and ground-based performance of the CSPE method for total I. The results demonstrate that CSPE technology is poised to meet NASA's total I monitoring requirements.
Liu, Jinchuan; Guan, Zheng; Lv, Zhenzhen; Jiang, Xiaoling; Yang, Shuming; Chen, Ailiang
2014-02-15
Gold nanoparticles (AuNPs) based fluorescence quenching or colorimetric aptasensor have been developed for many analytes recently largely because of the ease of detection, high sensitivity, and potential for high-throughput analysis. However, the effects of remnant non-AuNPs components in the colloid gold solution on these assays performance remain unclear. For the first time, we demonstrated that the remnant sodium citrate and the reaction products of three acids play counteractive roles in AuNPs based fluorescence quenching and colorimetric aptasensor in three ways in this study. First, the remnant sodium citrate in the colloid gold solution could increase the fluorescence intensity of FAM labeled on the aptamer that reduce the efficiency of AuNPs fluorescent quenching. Second, the reaction products of citric acid, HCl and ketoglutaric acid reduce the fluorescence recovery by quenching the fluorescence of FAM labeled on the aptamer dissociated from the surface of AuNPs upon addition of target. Lastly, the reaction products of three acids reduce the pH value of the colloid gold solution that reduce the sensitivity of AuNPs based colorimetric aptasensor by increasing the adsorption of aptamer to surface of AuNPs. With sulfadimethoxine and thrombin as model analytes, we found that water resuspended AuNPs can significantly increase the sensitivity by more than 10-fold for AuNPs based fluorescence quenching aptasensor. In the AuNPs based colorimetric aptasensor for sulfadimethoxine using the water resuspended AuNPs, the sensitivity also was increased by 10-fold compared with that of original AuNPs. The findings in this study provide theoretical guidance for further improving AuNPs based fluorescent quenching and colorimetric aptasensor by adjusting the composition of AuNPs solution. © 2013 Elsevier B.V. All rights reserved.
New data on the peculiar galaxy MRK 273
NASA Technical Reports Server (NTRS)
Asatrian, A. S.; Petrosian, A. R.; Boerngen, F.
1990-01-01
Colorimetric and spectral investigations of Markarian 273 and its three neighbors were performed on the basis of direct ultraviolet blue visual (UBV) and spectral observations with the 2-m Tautenburg telescope and the 6-m telescope of the Special Astrophysical Observatory of the USSR Academy of Sciences. The results obtained suggest that this galaxy is a close system of two objects with active nuclei. The observed straight tail with a thermal emission character is probably the result of the interaction of these galaxies.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Gaynor, James D.; Karakoti, Ajay S.; Inerbaev, Talgat
2013-05-02
A single layer of oxygen-deficient cerium oxide nanoparticles (CNPs) are immobilized on microscopic glass slide using poly(4-vinylpyridine) (PVP) self-assembled monolayers (SAMs). A specific colorimetric property of CNPs when reacted with hydrogen peroxide allows for the direct, single-step peroxide detection which can be used in medical diagnosis and explosives detection. Multiple PVP-CNP immobilized layers improve sensitivity of detection and the sensor can be regenerated for reuse.
Detection and differentiation of coxiella burnetii in biological fluids
Frazier, Marvin E.; Mallavia, Louis P.; Samuel, James E.; Baca, Oswald G.
1990-01-01
Methods for detecting the presence of Coxiella burenetii in biological samples, as well as a method for differentiating strains of C. burnetii that are capable of causing acute disease from those strains capable of causing chronic disease are disclosed. The methods generally comprise treating cells contained within the biological sample to expose cellular DNA, and hybridizing the cellular DNA (specifically rickettsial DNA) with a C. burnetii-specific labeled DNA probe. Radioisotope and biotin labels are preferred, allowing detection through autoradiography and colorimetric assays, respectively.
Detection and differentiation of coxiella burnetii in biological fluids
Frazier, Marvin E.; Mallavia, Louis P.; Baca, Oswald G.; Samuel, James E.
1989-01-01
Methods for detecting the presence of Coxiella burnetii in biological samples, as well as a method for differentiating strains of C. burnetii that are capable of causing acute disease from those strains capable of causing chronic disease are disclosed. The methods generally comprise treating cells contained within the biological sample to expose cellular DNA, and hybridizing the cellular DNA (specifically rickettsial DNA) with a C. burnetii-specific labeled DNA probe. Radioisotope and biotin labels are preferred, allowing detection through autoradiography and colorimetric assays, respectively.
Determination of micro amounts of iron, aluminum, and alkaline earth metals in silicon carbide
NASA Technical Reports Server (NTRS)
Hirata, H.; Arai, M.
1978-01-01
A colorimetric method for analysis of micro components in silicon carbide used as the raw material for varistors is described. The microcomponents analyzed included iron soluble in hydrochloric acid, iron, aluminum, calcium and magnesium. Samples were analyzed by the method, and the results for iron and aluminum agreed well with the N.B.S. standard values and the values obtained by the other company. The method can therefore be applied to the analysis of actual samples.
Distribution and determination of cholinesterases in mammals
Holmstedt, Bo
1971-01-01
This paper reviews the distribution of cholinesterases in the central nervous system, the ganglia, the striated muscle, and the blood of mammals, and discusses the correlation between the histochemical localization and the function of neuronal cholinesterase. Different methods for the determination of cholinesterase levels are reviewed, with particular reference to their practical value for field work. The Warburg method and the Tintometer and Acholest colorimetric methods are compared on the basis of cholinesterase levels determined in normal persons and in those suffering from parathion intoxication. PMID:4999484
The use of colorimetric sensor arrays to discriminate between pathogenic bacteria.
Lonsdale, Claire L; Taba, Brian; Queralto, Nuria; Lukaszewski, Roman A; Martino, Raymond A; Rhodes, Paul A; Lim, Sung H
2013-01-01
A colorimetric sensor array is a high-dimensional chemical sensor that is cheap, compact, disposable, robust, and easy to operate, making it a good candidate technology to detect pathogenic bacteria, especially potential bioterrorism agents like Yersinia pestis and Bacillus anthracis which feature on the Center for Disease Control and Prevention's list of potential biothreats. Here, a colorimetric sensor array was used to continuously monitor the volatile metabolites released by bacteria in solid media culture in an Advisory Committee on Dangerous Pathogen Containment Level 3 laboratory. At inoculum concentrations as low as 8 colony-forming units per plate, 4 different bacterial species were identified with 100% accuracy using logistic regression to classify the kinetic profile of sensor responses to culture headspace gas. The sensor array was able to further discriminate between different strains of the same species, including 5 strains of Yersinia pestis and Bacillus anthracis. These preliminary results suggest that disposable colorimetric sensor arrays can be an effective, low-cost tool to identify pathogenic bacteria.
Sun, Xiange; Li, Bowei; Qi, Anjin; Tian, Chongguo; Han, Jinglong; Shi, Yajun; Lin, Bingcheng; Chen, Lingxin
2018-02-01
In this work, a novel rotational microfluidic paper-based device was developed to improve the accuracy and performance of the multiplexed colorimetric detection by effectively avoiding the diffusion of colorimetric reagent on the detection zone. The integrated paper-based rotational valves were used to control the connection or disconnection between detection zones and fluid channels. Based on the manipulation of the rotational valves, this rotational paper-based device could prevent the random diffusion of colorimetric reagent and reduce the error of quantitative analysis considerably. The multiplexed colorimetric detection of heavy metals Ni(II), Cu(II) and Cr(VI) were implemented on the rotational device and the detection limits could be found to be 4.8, 1.6, and 0.18mg/L, respectively. The developed rotational device showed the great advantage in improving the detection accuracy and was expected to be a low-cost, portable analytical platform for the on-site detection. Copyright © 2017 Elsevier B.V. All rights reserved.
The Use of Colorimetric Sensor Arrays to Discriminate between Pathogenic Bacteria
Lonsdale, Claire L.; Taba, Brian; Queralto, Nuria; Lukaszewski, Roman A.; Martino, Raymond A.; Rhodes, Paul A.; Lim, Sung H.
2013-01-01
A colorimetric sensor array is a high-dimensional chemical sensor that is cheap, compact, disposable, robust, and easy to operate, making it a good candidate technology to detect pathogenic bacteria, especially potential bioterrorism agents like Yersinia pestis and Bacillus anthracis which feature on the Center for Disease Control and Prevention’s list of potential biothreats. Here, a colorimetric sensor array was used to continuously monitor the volatile metabolites released by bacteria in solid media culture in an Advisory Committee on Dangerous Pathogen Containment Level 3 laboratory. At inoculum concentrations as low as 8 colony-forming units per plate, 4 different bacterial species were identified with 100% accuracy using logistic regression to classify the kinetic profile of sensor responses to culture headspace gas. The sensor array was able to further discriminate between different strains of the same species, including 5 strains of Yersinia pestis and Bacillus anthracis. These preliminary results suggest that disposable colorimetric sensor arrays can be an effective, low-cost tool to identify pathogenic bacteria. PMID:23671629
NASA Astrophysics Data System (ADS)
Liu, Yan; Chen, Qinghan; Bu, Xianhui; Feng, Pingyun
2002-06-01
The rare earth element neodymium doped yttrium aluminum garnet (Nd:YAG) is a laser crystal widely used for producing laser in the infrared range. Neodymium causes many characteristic absorption peaks in the transmittance spectrum of the Nd:YAG crystal in the visible range. The crystal appears pink under daylight and incandescent light, and colorless under fluorescent light. The colorimetric calculation results of chroma under the CIE standard fluorescent illuminant F7 do not agree with the color appearance under fluorescent light. The calculated chroma values should be near zero to agree with a colorless appearance, but it is actually 11.79 in the CIELAB color space. This failure of the colorimetric calculation is caused by the color matching functions of the CIE colorimetric observers. The color matching functions do not agree with the spectral sensitivity curves of the human eye, especially the x(λ) function does not matches the spectral sensitivity curve of the long wavelength cone photoreceptors.
Hassan, Wafaa El-Sayed
2008-08-01
Three rapid, simple, reproducible and sensitive extractive colorimetric methods (A--C) for assaying dothiepin hydrochloride (I) and risperidone (II) in bulk sample and in dosage forms were investigated. Methods A and B are based on the formation of an ion pair complexes with methyl orange (A) and orange G (B), whereas method C depends on ternary complex formation between cobalt thiocyanate and the studied drug I or II. The optimum reaction conditions were investigated and it was observed the calibration curves resulting from the measurements of absorbance concentration relations of the extracted complexes were linear over the concentration range 0.1--12 microg ml(-1) for method A, 0.5--11 mug ml(-1) for method B, and 3.2--80 microg ml(-1) for method C with a relative standard deviation (RSD) of 1.17 and 1.28 for drug I and II, respectively. The molar absorptivity, Sandell sensitivity, Ringbom optimum concentration ranges, and detection and quantification limits for all complexes were calculated and evaluated at maximum wavelengths of 423, 498, and 625 nm, using methods A, B, and C, respectively. The interference from excipients commonly present in dosage forms and common degradation products was studied. The proposed methods are highly specific for the determination of drugs I and II, in their dosage forms applying the standard additions technique without any interference from common excipients. The proposed methods have been compared statistically to the reference methods and found to be simple, accurate (t-test) and reproducible (F-value).
Pre-oxidation for Colorimetric Sensor Array Detection of VOCs
Lin, Hengwei; Jang, Minseok; Suslick, Kenneth S.
2011-01-01
A disposable pre-oxidation technique is reported that dramatically improves the detection and identification of volatile organic compounds (VOCs) by a colorimetric sensor array. By passing a vapor stream through a tube packed with chromic acid on silica immediately before the colorimetric sensor array, the sensitivity to less reactive VOCs is substantially increased and limits of detection (LODs) are improved ~300-fold, permitting the detection, identification, and discrimination of 20 commonly found indoor VOC pollutants at both their immediately dangerous to life or health (IDLH) and at permissible exposure limits (PEL) concentrations. LODs of these pollutants were on average 1.4% of their respective PELs. PMID:21967478
Sensitiveness of the colorimetric estimation of titanium
Wells, R.C.
1911-01-01
The accuracy of the colorimetric estimation of titanium is practically constant over concentrations ranging from the strongest down to those containing about 1.5 mg. TiO2 in 100 cc. The change in concentration required to produce a perceptible difference in intensity between two solutions, at favorable concentrations, was found to be about 6.5 per cent, which does not differ much from the results of others with chromium and copper solutions. With suitable precautions, such as comparing by substitution and taking the mean of several settings or of the two perceptibly different extremes, the accuracy of the colorimetric comparisons appears to be about 2 per cent.
Colorimetric analysis of outdoor illumination across varieties of atmospheric conditions.
Peyvandi, Shahram; Hernández-Andrés, Javier; Olmo, F J; Nieves, Juan Luis; Romero, Javier
2016-06-01
Solar illumination at ground level is subject to a good deal of change in spectral and colorimetric properties. With an aim of understanding the influence of atmospheric components and phases of daylight on colorimetric specifications of downward radiation, more than 5,600,000 spectral irradiance functions of daylight, sunlight, and skylight were simulated by the radiative transfer code, SBDART [Bull. Am. Meteorol. Soc.79, 2101 (1998)], under the atmospheric conditions of clear sky without aerosol particles, clear sky with aerosol particles, and overcast sky. The interquartile range of the correlated color temperatures (CCT) for daylight indicated values from 5712 to 7757 K among the three atmospheric conditions. A minimum CCT of ∼3600 K was found for daylight when aerosol particles are present in the atmosphere. Our analysis indicated that hemispheric daylight with CCT less than 3600 K may be observed in rare conditions in which the level of aerosol is high in the atmosphere. In an atmosphere with aerosol particles, we also found that the chromaticity of daylight may shift along the green-purple direction of the Planckian locus, with a magnitude depending on the spectral extinction by aerosol particles and the amount of water vapor in the atmosphere. The data analysis showed that an extremely high value of CCT, in an atmosphere without aerosol particles, for daylight and skylight at low sun, is mainly due to the effect of Chappuis absorption band of ozone at ∼600 nm. In this paper, we compare our data with well-known observations from previous research, including the ones used by the CIE to define natural daylight illuminants.
Li, Jian; Ren, Shujuan; Han, Shaolun; Li, Na
2014-04-01
The present study introduces an improved yeast bioassay for rapid yet sensitive evaluation of thyroid hormone disruption at the level of thyroid receptor (TR) in environmental water samples. This assay does not require water sample preparation and thus requires very little hands-on time. Based on different β-galactosidase substrates, two modified bioassays, a colorimetric bioassay and a chemiluminescent bioassay, were developed. The compounds tested included the known thyroid hormone 3,3',5-triiodo-l-thyronine (T3), the specific TR antagonist amiodarone hydrochloride (AH) and phthalate esters (PAEs), which potentially disrupt thyroid hormone signaling. The EC50 values for T3 were similar to those previously obtained using a 96-well plate bioassay. TR antagonism by AH was studied in the presence of 2.5 × 10(-7)M T3, and the concentration producing 20% of the maximum effect (RIC20) for AH was 3.1 × 10(-7)M and 7.8 × 10(-9)M for the colorimetric bioassay and chemiluminescent bioassay, respectively. None of the tested PAEs induced β-galactosidase expression, but diethylhexyl phthalate, benzyl butyl phthalate and dibutyl phthalate demonstrated TR antagonism. Furthermore, water samples collected from Guanting reservoir in Beijing were evaluated. Although TR agonism was not observed, antagonism was detected in all water samples and is expressed as AH equivalents. The toxicology equivalent quantity values obtained by the chemiluminescent bioassay ranged from 21.2 ± 1.6 to 313.9 ± 28.8 μg L(-1) AH, and similar values were obtained for the colorimetric bioassay. The present study shows that the modified yeast bioassay can be used as a valuable tool for quantification of thyroid hormone disrupting effects in environmental water samples. Copyright © 2013 Elsevier Ltd. All rights reserved.
Colorimetric Aptasensor Using Unmodified Gold Nanoparticles for Homogeneous Multiplex Detection
Niu, Shucao; Lv, Zhenzhen; Liu, Jinchuan; Bai, Wenhui; Yang, Shuming; Chen, Ailiang
2014-01-01
Colorimetric aptasensors using unmodified gold nanoparticles (AuNPs) have attracted much attention because of their low cost, simplicity, and practicality, and they have been developed for various targets in the past several years. However, previous research has focused on developing single-target assays. Here, we report the development of a homogeneous multiplex aptasensor by using more than one class of aptamers to stabilize AuNPs. Using sulfadimethoxine (SDM), kanamycin (KAN) and adenosine (ADE) as example targets, a KAN aptamer (750 nM), an SDM aptamer (250 nM) and an ADE aptamer (500 nM) were mixed at a 1∶1∶1 volume ratio and adsorbed directly onto the surface of unmodified AuNPs by electrostatic interaction. Upon the addition of any of the three targets, the conformation of the corresponding aptamer changed from a random coil structure to a rigid folded structure, which could not adsorb and stabilize AuNPs. The AuNPs aggregated in a specific reaction buffer (20 mM Tris-HCl containing 20 mM NaCl and 5 mM KCl), which led to a color change from red to purple/blue. These results demonstrate that the multiplex colorimetric aptasensor detected three targets simultaneously while maintaining the same sensitivity as a single-target aptasensor for each individual target. The multiplex aptasensor could be extended to other aptamers for various molecular detection events. Due to its simple design, easy operation, fast response, cost effectiveness and lack of need for sophisticated instrumentation, the proposed strategy provides a powerful tool to examine large numbers of samples to screen for a small number of potentially positive samples containing more than one analyte, which can be further validated using sophisticated instruments. PMID:25279730
Measurement of the surface wavelength distribution of narrow-band radiation by a colorimetric method
DOE Office of Scientific and Technical Information (OSTI.GOV)
Kraiskii, A V; Mironova, T V; Sultanov, T T
2010-09-10
A method is suggested for determining the wavelength of narrow-band light from a digital photograph of a radiating surface. The digital camera used should be appropriately calibrated. The accuracy of the wavelength measurement is better than 1 nm. The method was tested on the yellow doublet of mercury spectrum and on the adjacent continuum of the incandescent lamp radiation spectrum. By means of the method suggested the homogeneity of holographic sensor swelling was studied in stationary and transient cases. (laser applications and other topics in quantum electronics)
NASA Astrophysics Data System (ADS)
Kraiskii, A. V.; Mironova, T. V.; Sultanov, T. T.
2010-09-01
A method is suggested for determining the wavelength of narrow-band light from a digital photograph of a radiating surface. The digital camera used should be appropriately calibrated. The accuracy of the wavelength measurement is better than 1 nm. The method was tested on the yellow doublet of mercury spectrum and on the adjacent continuum of the incandescent lamp radiation spectrum. By means of the method suggested the homogeneity of holographic sensor swelling was studied in stationary and transient cases.
Highly Sensitive Colorimetric Cancer Cell Detection Based on Dual Signal Amplification.
Yu, Tao; Dai, Pan-Pan; Xu, Jing-Juan; Chen, Hong-Yuan
2016-02-01
Facile and efficient detection of cancer cells at their preclinical stages is one of the central challenges in cancer diagnostics. A direct, rapid, highly sensitive and specific biosensor for detection of cancer biomarkers is desirable in early diagnosis and prognosis of cancer. In this work, we developed, for the first time, an easy and intuitive dispersion-dominated colorimetric strategy for cancer cell detection based on combining multi-DNA released from an aptamer scaffold with cyclic enzymatic amplification, which was triggered by aptamer DNA conformational switch and demonstrated by non-cross-linking gold nanoparticles (Au NPs) aggregation. First, five kinds of messenger DNAs (mDNAs) were aligned on the cancer cell aptamers modified on magnetic beads (MBs) to form mDNAs-Apt-MBs biocompatible nanosensors. In the presence of target cells, the aptamer would bind to the receptors on the cell membranes, and mDNAs would be released, resulting in the first amplification that one biological binding event would cause the release of multiple kinds of mDNAs simultaneously. After magnetic separation, the released mDNAs were introduced into the cyclic enzymatic amplification to cleave more single strand DNA (ssDNA) fragments. Instead of modification of Au NPs, these fragments and mDNAs could be adsorbed on the surface of Au NPs to prevent particle aggregation and ensure the stability and color of solution in high salt environments. The linear response for HL-60 cells in a concentration range from 10 to 10(4) cells was obtained with a detection limit of four cells in buffer solution. Moreover, the feasibility of the proposed strategy was demonstrated in a diluted serum sample. This dual signal amplification method can be extended to other types of cancer cells, which has potential application in point-of-care cancer diagnosis.
Terenteva, E A; Apyari, V V; Dmitrienko, S G; Garshev, A V; Volkov, P A; Zolotov, Yu A
2018-04-01
Positively charged polyhexamethylene guanidine hydrochloride-stabilized silver nanoparticles (PHMG-AgNPs) were prepared and applied as a colorimetric probe for single-step determination of pyrophosphate and sulfate. The approach is based on the nanoparticles aggregation leading to change in their absorption spectra and color of the solution. Due to both electrostatic and steric stabilization these nanoparticles show decreased sensitivity relatively to many common anions, which allows for simple and rapid direct single-step determination of pyrophosphate and sulfate. Effects of different factors (time of interaction, pH, concentrations of anions and the nanoparticles) on aggregation of PHMG-AgNPs and analytical performance of the procedure were investigated. The method allows for the determination of pyrophosphate and sulfate in the range of 0.16-2μgmL -1 and 20-80μgmL -1 with RSD of 2-5%, respectively. The analysis can be performed using either spectrophotometry or naked-eye detection. Practical application of the method was shown by the example of pyrophosphate determination in baking powder sample. Copyright © 2017 Elsevier B.V. All rights reserved.
Gonzalez, Aroa Garcia; Taraba, Lukáš; Hraníček, Jakub; Kozlík, Petr; Coufal, Pavel
2017-01-01
Dasatinib is a novel oral prescription drug proposed for treating adult patients with chronic myeloid leukemia. Three analytical methods, namely ultra high performance liquid chromatography, capillary zone electrophoresis, and sequential injection analysis, were developed, validated, and compared for determination of the drug in the tablet dosage form. The total analysis time of optimized ultra high performance liquid chromatography and capillary zone electrophoresis methods was 2.0 and 2.2 min, respectively. Direct ultraviolet detection with detection wavelength of 322 nm was employed in both cases. The optimized sequential injection analysis method was based on spectrophotometric detection of dasatinib after a simple colorimetric reaction with folin ciocalteau reagent forming a blue-colored complex with an absorbance maximum at 745 nm. The total analysis time was 2.5 min. The ultra high performance liquid chromatography method provided the lowest detection and quantitation limits and the most precise and accurate results. All three newly developed methods were demonstrated to be specific, linear, sensitive, precise, and accurate, providing results satisfactorily meeting the requirements of the pharmaceutical industry, and can be employed for the routine determination of the active pharmaceutical ingredient in the tablet dosage form. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Development and application of colorimetric microassay for determining boron-containing compounds
S. Nami Kartal; Frederick Green
2002-01-01
This paper describes the development of a microsssay for boron and the application of this microassay for evaluating leachability of boron by post-treatment of southern pine with the calcium precipitating agent NHA (N'N-napthaloylhydroxylamine). The microsssay method for quantitative estimation of boron content in treated wood and leachates is a microadaptation of...
USDA-ARS?s Scientific Manuscript database
Shiga toxin-producing Escherichia coli O157:H7 is a leading cause of foodborne illness worldwide. To evaluate better methods to rapidly detect and genotype E. coli O157 virulent strains, the present study explored the use of photopolymerization, a colorimetric and photoinduced signal amplification d...
NASA Astrophysics Data System (ADS)
Pylaev, T. E.; Khanadeev, V. A.; Khlebtsov, B. N.; Dykman, L. A.; Bogatyrev, V. A.; Khlebtsov, N. G.
2011-07-01
We introduce a new genosensing approach employing CTAB (cetyltrimethylammonium bromide)-coated positively charged colloidal gold nanoparticles (GNPs) to detect target DNA sequences by using absorption spectroscopy and dynamic light scattering. The approach is compared with a previously reported method employing unmodified CTAB-coated gold nanorods (GNRs). Both approaches are based on the observation that whereas the addition of probe and target ssDNA to CTAB-coated particles results in particle aggregation, no aggregation is observed after addition of probe and nontarget DNA sequences. Our goal was to compare the feasibility and sensitivity of both methods. A 21-mer ssDNA from the human immunodeficiency virus type 1 HIV-1 U5 long terminal repeat (LTR) sequence and a 23-mer ssDNA from the Bacillus anthracis cryptic protein and protective antigen precursor (pagA) genes were used as ssDNA models. In the case of GNRs, unexpectedly, the colorimetric test failed with perfect cigar-like particles but could be performed with dumbbell and dog-bone rods. By contrast, our approach with cationic CTAB-coated GNPs is easy to implement and possesses excellent feasibility with retention of comparable sensitivity—a 0.1 nM concentration of target cDNA can be detected with the naked eye and 10 pM by dynamic light scattering (DLS) measurements. The specificity of our method is illustrated by successful DLS detection of one-three base mismatches in cDNA sequences for both DNA models. These results suggest that the cationic GNPs and DLS can be used for genosensing under optimal DNA hybridization conditions without any chemical modifications of the particle surface with ssDNA molecules and signal amplification. Finally, we discuss a more than two-three-order difference in the reported estimations of the detection sensitivity of colorimetric methods (0.1 to 10-100 pM) to show that the existing aggregation models are inconsistent with the detection limits of about 0.1-1 pM DNA and that other explanations should be developed.
A Colorimetric Process to Visualize Erythrocyte Exovesicles Aggregates
ERIC Educational Resources Information Center
Saldanha, Carlota; Santos, Nuno C.; Martins-Silva, J.
2004-01-01
A biochemistry laboratory class protocol is described in order to create an opportunity for students to apply by doing the theoretical concepts underlying biomolecules and vesicles properties, together with the principles of centrifugation and colorimetric methodologies. Through simple procedures the students will i) observe the segregation of the…
Evaluation of a Colorimetric Personal Dosimeter for Nitrogen Oxide.
ERIC Educational Resources Information Center
Diamond, Philip
A personal colorimetric dosimeter for nitrogen dioxide was developed. Tests were performed to determine the response of these strips to various concentrations of NO2. The dosimeter strips were satisfactory for approximate determinations of total exposure (concentration + time) of nitrogen dioxide. The total exposure was calculated in terms of time…
Baker, Matthew S; Phillips, Scott T
2012-05-14
This article describes a small molecule reagent that is capable of detecting fluoride down to 0.12 mM (2.3 ppm) in water. The reagent reveals this level of fluoride through a novel autoinductive signal amplification reaction that produces an unambiguous colorimetric readout.
NASA Technical Reports Server (NTRS)
Chapman, K. B.; Mihaylov, G. M.; Kirollos, K. S.
2000-01-01
Monitoring the exposure of an employee to hydrogen chloride or hydrochloric acid in the presence of other acids has been a challenge to the industrial hygiene community. The capability of a device to differentiate the levels of acid vapors would allow for more accurate determinations of exposure and therefore improved occupational health. In this work, a selective direct-read colorimetric badge system was validated for Short Term Exposure Limit (STEL) monitoring of hydrogen chloride. The passive colorimetric badge system consists of a direct reading badge and a color scale. The badge has a coated indicator layer with a diffusive resistance in the shape of an exclamation mark. An exclamation mark will appear if hydrogen chloride is present in the atmosphere at concentrations at or above 2.0 ppm. By using the color scale, the intensity of the color formed on the badge can be further quantified up to 25 ppm. The system was validated according to a protocol based on the NIOSH Protocol for the Evaluation of Passive Monitors. The badge was exposed to relative humidities ranging from 11% to 92%, temperatures ranging from 7 C to 400 C and air velocities ranging from 5 cm/sec to 170 cm/sec. All experiments were conducted in a laboratory vapor generation system. Hydrofluoric acid, nitric acid, sulfuric acid, chlorine, hydrogen sulfide and organic acids showed no effect on the performance of the hydrogen chloride monitoring system. The passive badge and color scale system exceeded the accuracy requirements as defined by NIOSH. At ambient conditions, the mean coefficient of variation was 10.86 and the mean bias was 1.3%. This data was presented previously at the American Industrial Hygiene Conference and Exposition in Toronto, Canada in June 1999.
Shinohara, Naohide; Kajiwara, Tomohisa; Ohnishi, Masato; Kodama, Kenichi; Yanagisawa, Yukio
2008-06-15
A coin-sized passive emission colorimetric sensor (PECS) based on an enzymatic reaction and a portable reflectance photometry device were developed to determine the emission rates of formaldehyde from building materials and other materials found indoors in only 30 minutes on-site. The color change of the PECS linearly correlated to the concentration of formaldehyde aqueous solutions up to 28 microg/mL. The correlation between the emission rates measured by using the PECS and those measured by using a desiccator method or by using a chamber method was fitted with a linear function and a power function, and the determination coefficients were more than 0.98. The reproducible results indicate that the emission rates could be obtained with the correlation equations from the data measured by using the PECS and the portable reflectance photometry device. Limits of detection (LODs) were 0.051 mg/L for the desiccator method and 3.1 microg/m2/h for the chamber method. Thus, it was confirmed that the emission rates of formaldehyde from the building materials classified as F four-star (< 0.3 mg/L (desiccator method) or < 5.0 microg/m2/h (chamber method)), based on Japanese Industrial Standards (JIS), could be measured with the PECS. The measurement with PECS was confirmed to be precise (RSD < 10%). Other chemicals emitted from indoor materials, such as methanol, ethanol, acetone, toluene, and xylene, interfered little with the measurement of formaldehyde emission rates by using the PECS.
Rubber (Hevea brasiliensis) seed oil toxicity effect and Linamarin compound analysis.
Salimon, Jumat; Abdullah, Bashar Mudhaffar; Salih, Nadia
2012-06-13
The lipid fraction of rubber (Hevea brasiliensis (kunth. Muell)) seed was extracted and analyzed for toxicological effect. The toxicological compound such as linamarin in rubber seed oil (RSO) extracted using different solvents, such as hexane (RSOh), mixture of chloroform + methanol (RSOchl+mth) and ethanol (RSOeth) were also studied. Various methods analysis such as Fourier transforms infrared spectroscopy (FTIR) and colorimetric methods were carried out to determine the present of such compounds. FTIR spectrum of RSO did not show any presence of cyanide peak. The determination of cyanide by using colorimetric method was demonstrated no response of the cyanide in RSO and didn't show any colored comparing with commercial cyanide which observed blue color. The results showed that no functional groups such as cyanide (C ≡ N) associated with linamarin were observed. Toxicological test using rats was also conducted to further confirm the absence of such compounds. RSO did not show any toxic potential to the rats. Bioassay experiments using shrimps had been used as test organisms to evaluate the toxicity of linamarin extract from RSO(h,) RSO(chl+mth) and RSO(eth) and LC50 were found to be (211.70 %, 139.40 %, and 117.41 %, respectively). This can be attributed no hazardous linamarin were found in RSO.
Dawan, Phanphruk; Satarpai, Thiphol; Tuchinda, Patoomratana; Shiowatana, Juwadee; Siripinyanond, Atitaya
2017-01-01
A new analytical platform based on the use of thin-layer chromatography (TLC) coupled with paper-based analytical device (PAD) was developed for the determination of total capsaicinoids in chilli samples. This newly developed TLC-PAD is simple and low-cost without any requirement of special instrument or skillful person. The analysis consisted of two steps, i.e., extraction of capsaicinoids from chilli samples by using ethanol as solvent and separation of capsaicinoids by thin-layer chromatography (TLC) and elution of capsaicinoids from the TLC plate with in situ colorimetric detection of capsaicinoids on the PAD. For colorimetric detection, Folin-Ciocalteu reagent was used to detect phenolic functional group of capsaicinoids yielding the blue color. The blue color on the PAD was imaged by a scanner followed by evaluation of its grayscale intensity value by ImageJ program. This newly developed TLC-PAD method provided a linear range from 50 to 1000mgL -1 capsaicinoids with the limit of detection as low as 50mgL -1 capsaicinoids. The proposed method was applied to determine capsaicinoids in dried chilli and seasoning powder samples and the results were in good agreement with those obtained by HPLC method. Copyright © 2016 Elsevier B.V. All rights reserved.
Rubber (Hevea brasiliensis) seed oil toxicity effect and Linamarin compound analysis
2012-01-01
Background The lipid fraction of rubber (Hevea brasiliensis (kunth. Muell)) seed was extracted and analyzed for toxicological effect. The toxicological compound such as linamarin in rubber seed oil (RSO) extracted using different solvents, such as hexane (RSOh), mixture of chloroform + methanol (RSOchl+mth) and ethanol (RSOeth) were also studied. Various methods analysis such as Fourier transforms infrared spectroscopy (FTIR) and colorimetric methods were carried out to determine the present of such compounds. Results FTIR spectrum of RSO did not show any presence of cyanide peak. The determination of cyanide by using colorimetric method was demonstrated no response of the cyanide in RSO and didn’t show any colored comparing with commercial cyanide which observed blue color. The results showed that no functional groups such as cyanide (C ≡ N) associated with linamarin were observed. Toxicological test using rats was also conducted to further confirm the absence of such compounds. RSO did not show any toxic potential to the rats. Bioassay experiments using shrimps had been used as test organisms to evaluate the toxicity of linamarin extract from RSOh, RSOchl+mth and RSOeth and LC50 were found to be (211.70 %, 139.40 %, and 117.41 %, respectively). Conclusions This can be attributed no hazardous linamarin were found in RSO. PMID:22694753
Metzger, E; Viollier, E; Simonucci, C; Prévot, F; Langlet, D; Jézéquel, D
2013-10-01
Constrained DET (Diffusive Equilibration in Thin films) probes equipped with 75 sampling layers of agarose gel (DGT Research(©)) were used to sample bottom and pore waters in marine sediment with a 2 mm vertical resolution. After retrieval, each piece of hydrogel, corresponding to 25 μL, was introduced into 1 mL of colorimetric reagent (CR) solution consisting of formic acid and bromophenol blue. After the elution/reaction time, absorbance of the latter mixture was read at 590 nm and compared to a calibration curve obtained with the same protocol applied to mini DET probes soaked in sodium hydrogen carbonate standard solutions. This method allows rapid alkalinity determinations for the small volumes of anoxic pore water entrapped into the gel. The method was assessed on organic-rich coastal marine sediments from Thau lagoon (France). Alkalinity values in the overlying waters were in agreement with data obtained by classical sampling techniques. Pore water data showed a progressive increase of alkalinity in the sediment from 2 to 10 mmol kg(-1), corresponding to anaerobic respiration in organic-rich sediments. Moreover, replicates of high-resolution DET profiles showed important lateral heterogeneity at a decimeter scale. This underlines the importance of high-resolution spatial methods for alkalinity profiling in coastal marine systems. Copyright © 2013 Elsevier Ltd. All rights reserved.
Tee-ngam, Prinjaporn; Nunant, Namthip; Rattanarat, Poomrat; Siangproh, Weena; Chailapakul, Orawon
2013-01-01
Ferulic acid is an important phenolic antioxidant found in or added to diet supplements, beverages, and cosmetic creams. Two designs of paper-based platforms for the fast, simple and inexpensive evaluation of ferulic acid contents in food and pharmaceutical cosmetics were evaluated. The first, a paper-based electrochemical device, was developed for ferulic acid detection in uncomplicated matrix samples and was created by the photolithographic method. The second, a paper-based colorimetric device was preceded by thin layer chromatography (TLC) for the separation and detection of ferulic acid in complex samples using a silica plate stationary phase and an 85:15:1 (v/v/v) chloroform: methanol: formic acid mobile phase. After separation, ferulic acid containing section of the TLC plate was attached onto the patterned paper containing the colorimetric reagent and eluted with ethanol. The resulting color change was photographed and quantitatively converted to intensity. Under the optimal conditions, the limit of detection of ferulic acid was found to be 1 ppm and 7 ppm (S/N = 3) for first and second designs, respectively, with good agreement with the standard HPLC-UV detection method. Therefore, these methods can be used for the simple, rapid, inexpensive and sensitive quantification of ferulic acid in a variety of samples. PMID:24077320
Flux of Nutrients Between the Middle and Southern Adriatic Sea (Gargano-Split section)
2013-04-28
silico molybdate in acid solution to mo- lybdenum blue by ascorbic acid . Oxalic acid is introduced to the sam- ple to minimize interferences from...sensitivity of this method. Nitrite is measured by reacting the sample under acidic conditions with sulfanilamide to form a diazo compound that then...colorimetric method in which a blue compound is formed by the reaction of phosphate, molybdate and antimony followed by reduction with ascorbic acid . The reduced
NASA Astrophysics Data System (ADS)
Quintela, Irwin A.; de Los Reyes, Benildo G.; Lin, Chih-Sheng; Wu, Vivian C. H.
2015-01-01
A simultaneous direct detection of Shiga-toxin producing strains of E. coli (STEC; ``Big Six'' - O26, O45, O103, O111, O121, and O145) as well as O157 strains by optical biosensing with oligonucleotide-functionalized gold nanoparticles (AuNPs) was developed. Initially, conserved regions of stx genes were amplified by asymmetric polymerase chain reaction (asPCR). Pairs of single stranded thiol-modified oligonucleotides (30-mer) were immobilized onto AuNPs and used as probes to capture regions of stx1 (119-bp) and/or stx2 (104-bp) genes from STEC strains. DNA samples from pure cultures and food samples were sandwich hybridized with AuNP-oligo probes at optimal conditions (50 °C, 30 min). A complex was formed from the hybridization of AuNP-probes and target DNA fragments that retained the initial red color of the reaction solutions. For non-target DNA, a color change from red to purplish-blue was observed following an increase in salt concentration, thus providing the basis of simultaneous direct colorimetric detection of target DNA in the samples. Enrichment and pooling systems were incorporated to efficiently process a large number of food samples (ground beef and blueberries) and detection of live targets. The detection limit was <1 log CFU g-1, requiring less than 1 h to complete after DNA sample preparation with 100% specificity. Gel electrophoresis verified AuNP-DNA hybridization while spectrophotometric data and transmission electron microscope (TEM) images supported color discrimination based on the occurrence of molecular aggregation. In conclusion, the significant features of this approach took advantage of the unique colorimetric properties of AuNPs as a low-cost and simple approach yet with high specificity for simultaneous detection of STEC strains.A simultaneous direct detection of Shiga-toxin producing strains of E. coli (STEC; ``Big Six'' - O26, O45, O103, O111, O121, and O145) as well as O157 strains by optical biosensing with oligonucleotide-functionalized gold nanoparticles (AuNPs) was developed. Initially, conserved regions of stx genes were amplified by asymmetric polymerase chain reaction (asPCR). Pairs of single stranded thiol-modified oligonucleotides (30-mer) were immobilized onto AuNPs and used as probes to capture regions of stx1 (119-bp) and/or stx2 (104-bp) genes from STEC strains. DNA samples from pure cultures and food samples were sandwich hybridized with AuNP-oligo probes at optimal conditions (50 °C, 30 min). A complex was formed from the hybridization of AuNP-probes and target DNA fragments that retained the initial red color of the reaction solutions. For non-target DNA, a color change from red to purplish-blue was observed following an increase in salt concentration, thus providing the basis of simultaneous direct colorimetric detection of target DNA in the samples. Enrichment and pooling systems were incorporated to efficiently process a large number of food samples (ground beef and blueberries) and detection of live targets. The detection limit was <1 log CFU g-1, requiring less than 1 h to complete after DNA sample preparation with 100% specificity. Gel electrophoresis verified AuNP-DNA hybridization while spectrophotometric data and transmission electron microscope (TEM) images supported color discrimination based on the occurrence of molecular aggregation. In conclusion, the significant features of this approach took advantage of the unique colorimetric properties of AuNPs as a low-cost and simple approach yet with high specificity for simultaneous detection of STEC strains. Electronic supplementary information (ESI) available. See DOI: 10.1039/c4nr05869k
Holman, Benjamin W B; Mao, Yanwei; Coombs, Cassius E O; van de Ven, Remy J; Hopkins, David L
2016-11-01
The relationship between instrumental colorimetric values (L*, a*, b*, the ratio of reflectance at 630nm and 580nm) and consumer perception of acceptable beef colour was evaluated using a web-based survey and standardised photographs of beef m. longissimus lumborum with known colorimetrics. Only L* and b* were found to relate to average consumer opinions of beef colour acceptability. Respondent nationality was also identified as a source of variation in beef colour acceptability score. Although this is a preliminary study with the findings necessitating additional investigation, these results suggest L* and b* as candidates for developing instrumental thresholds for consumer beef colour expectations. Crown Copyright © 2016. Published by Elsevier Ltd. All rights reserved.
Domínguez-Henao, Laura; Turolla, Andrea; Monticelli, Damiano; Antonelli, Manuela
2018-06-01
The recent growing interest in peracetic acid (PAA) as disinfectant for wastewater treatment demands reliable and readily-available methods for its measurement. In detail, the monitoring of PAA in wastewater treatment plants requires a simple, accurate, rapid and inexpensive measurement procedure. In the present work, a method for analyzing low concentrations of PAA, adapted from the US EPA colorimetric method for total chlorine, is assessed. This method employs N,N-diethyl-p-phenylelnediamine (DPD) in the presence of an excess of iodide in a phosphate buffer system. Pink colored species are produced proportionally to the concentration of PAA in the sample. Considering that PAA is available commercially as an equilibrium solution of PAA and hydrogen peroxide (H 2 O 2 ), a measurement method for H 2 O 2 is also investigated. This method, as the one for the determination of PAA, is also based on the oxidation of iodide to iodine, with the difference that ammonium molybdate Mo(VI) is added to catalyze the oxidation reaction between H 2 O 2 and iodide, quantifying the total peroxides (PAA+ H 2 O 2 ). The two methods are suitable for concentration ranges from about 0.1-1.65 mg L -1 and from about 0.3-3.3 mg L -1 , respectively for PAA and H 2 O 2 . Moreover, the work elucidates some relevant aspects related to the operational conditions, kinetics and the possible interference of H 2 O 2 on PAA measurement. Copyright © 2018 Elsevier B.V. All rights reserved.
Developing and Demonstrating an Augmented Reality Colorimetric Titration Tool
ERIC Educational Resources Information Center
Tee, Nicholas Yee Kwang; Gan, Hong Seng; Li, Jonathan; Cheong, Brandon Huey-Ping; Tan, Han Yen; Liew, Oi Wah; Ng, Tuck Wah
2018-01-01
The handling of chemicals in the laboratory presents a challenge in instructing large class sizes and when students are relatively new to the laboratory environment. In this work, we describe and demonstrate an augmented reality colorimetric titration tool that operates out of the smartphone or tablet of students. It allows multiple students to…
Holman, Benjamin W B; Collins, Damian; Kilgannon, Ashleigh K; Hopkins, David L
2018-01-01
The Nix Pro Colour Sensor™ (NIX) can be potentially used to measure meat colour, but procedural guidelines that assure measurement reproducibility and repeatability (precision) must first be established. Technical replicate number (r) will minimise response variation, measureable as standard error of predicted mean (SEM), and contribute to improved precision. Consequently, we aimed to explore the effects of r on NIX precision when measuring aged beef colour (colorimetrics; L*, a*, b*, hue and chroma values). Each colorimetric SEM declined with increasing r to indicate improved precision and followed a diminishing rate of improvement that allowed us to recommend r=7 for meat colour studies using the NIX. This definition was based on practical limitations and a* variability, as additional r would be required if other colorimetrics or advanced levels of precision are necessary. Beef ageing and display period, holding temperature, loin and sampled portion were also found to contribute to colorimetric variation, but were incorporated within our definition of r. Crown Copyright © 2017. Published by Elsevier Ltd. All rights reserved.
Characterization of a digital camera as an absolute tristimulus colorimeter
NASA Astrophysics Data System (ADS)
Martinez-Verdu, Francisco; Pujol, Jaume; Vilaseca, Meritxell; Capilla, Pascual
2003-01-01
An algorithm is proposed for the spectral and colorimetric characterization of digital still cameras (DSC) which allows to use them as tele-colorimeters with CIE-XYZ color output, in cd/m2. The spectral characterization consists of the calculation of the color-matching functions from the previously measured spectral sensitivities. The colorimetric characterization consists of transforming the RGB digital data into absolute tristimulus values CIE-XYZ (in cd/m2) under variable and unknown spectroradiometric conditions. Thus, at the first stage, a gray balance has been applied over the RGB digital data to convert them into RGB relative colorimetric values. At a second stage, an algorithm of luminance adaptation vs. lens aperture has been inserted in the basic colorimetric profile. Capturing the ColorChecker chart under different light sources, the DSC color analysis accuracy indexes, both in a raw state and with the corrections from a linear model of color correction, have been evaluated using the Pointer'86 color reproduction index with the unrelated Hunt'91 color appearance model. The results indicate that our digital image capture device, in raw performance, lightens and desaturates the colors.
NASA Astrophysics Data System (ADS)
Zong, Shenfei; Wang, Zhuyuan; Chen, Hui; Hu, Guohua; Liu, Min; Chen, Peng; Cui, Yiping
2014-01-01
As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis.As an important biomarker and therapeutic target, telomerase has attracted considerable attention concerning its detection and monitoring. Here, we present a colorimetry and surface enhanced Raman scattering (SERS) dual-mode telomerase activity detection method, which has several distinctive advantages. First, colorimetric functionality allows rapid preliminary discrimination of telomerase activity by the naked eye. Second, the employment of SERS technique results in greatly improved detection sensitivity. Third, the combination of colorimetry and SERS into one detection system can ensure highly efficacious and sensitive screening of numerous samples. Besides, the avoidance of polymerase chain reaction (PCR) procedures further guarantees fine reliability and simplicity. Generally, the presented method is realized by an ``elongate and capture'' procedure. To be specific, gold nanoparticles modified with Raman molecules and telomeric repeat complementary oligonucleotide are employed as the colorimetric-SERS bifunctional reporting nanotag, while magnetic nanoparticles functionalized with telomerase substrate oligonucleotide are used as the capturing substrate. Telomerase can synthesize and elongate telomeric repeats onto the capturing substrate. The elongated telomeric repeats subsequently facilitate capturing of the reporting nanotag via hybridization between telomeric repeat and its complementary strand. The captured nanotags can cause a significant difference in the color and SERS intensity of the magnetically separated sediments. Thus both the color and SERS can be used as indicators of the telomerase activity. With fast screening ability and outstanding sensitivity, we anticipate that this method would greatly promote practical application of telomerase-based early-stage cancer diagnosis. Electronic supplementary information (ESI) available: TEM images of individual MB@Au NPs, results of dynamic light scattering analysis and extinction spectrum obtained using colorimetry detection. See DOI: 10.1039/c3nr04942f
Li, Xiuyan; Cheng, Ruojie; Shi, Huijie; Tang, Bo; Xiao, Hanshuang; Zhao, Guohua
2016-03-05
A simple and highly sensitive aptamer-based colorimetric sensor was developed for selective detection of Microcystin-LR (MC-LR). The aptamer (ABA) was employed as recognition element which could bind MC-LR with high-affinity, while gold nanoparticles (AuNPs) worked as sensing materials whose plasma resonance absorption peaks red shifted upon binding of the targets at a high concentration of sodium chloride. With the addition of MC-LR, the random coil aptamer adsorbed on Au NPs altered into regulated structure to form MC-LR-aptamer complexes and broke away from the surface of Au NPs, leading to the aggregation of AuNPs, and the color converted from red to blue due to the interparticle plasmon coupling. Results showed that our aptamer-based colorimetric sensor exhibited rapid and sensitive detection performance for MC-LR with linear range from 0.5 nM to 7.5 μM and the detection limit reached 0.37 nM. Meanwhile, the pollutants usually coexisting with MC-LR in pollutant water samples had not demonstrated disturbance for detecting of MC-LR. The mechanism was also proposed suggesting that high affinity interaction between aptamer and MC-LR significantly enhanced the sensitivity and selectivity for MC-LR detection. Besides, the established method was utilized in analyzing real water samples and splendid sensitivity and selectivity were obtained as well. Copyright © 2015 Elsevier B.V. All rights reserved.
Cao, Gen-Xia; Wu, Xiu-Ming; Dong, Yu-Ming; Li, Zai-Jun; Wang, Guang-Li
2016-07-09
In this study, a simple and amplified colorimetric assay is developed for the detection of the enzymatic activity of glucose oxidase (GOx) based on in situ formation of a photoswitchable oxidase mimetic of PO₄(3-)-capped CdS quantum dots (QDs). GOx catalyzes the oxidation of 1-thio-β-d-glucose to give 1-thio-β-d-gluconic acid which spontaneously hydrolyzes to β-d-gluconic acid and H₂S; the generated H₂S instantly reacts with Cd(2+) in the presence of Na₃PO₄ to give PO₄(3-)-stabilized CdS QDs in situ. Under visible-light (λ ≥ 400 nm) stimulation, the PO₄(3-)-capped CdS QDs are a new style of oxidase mimic derived by producing some active species, such as h⁺, (•)OH, O₂(•-) and a little H₂O₂, which can oxidize the typical substrate (3,3,5,5-tetramethylbenzydine (TMB)) with a color change. Based on the GOx-triggered growth of the oxidase mimetics of PO₄(3-)-capped CdS QDs in situ, we developed a simple and amplified colorimetric assay to probe the enzymatic activity of GOx. The proposed method allowed the detection of the enzymatic activity of GOx over the range from 25 μg/L to 50 mg/L with a low detection limit of 6.6 μg/L. We believe the PO₄(3-)-capped CdS QDs generated in situ with photo-stimulated enzyme-mimicking activity may find wide potential applications in biosensors.
He, Yi; Wang, Li
2017-05-05
Here we report a label-free method for visual colorimetric detection of hexahydro-1,3,5-trinitro-1,3,5-triazine (HTT) explosive based on base-driven sunlight oxidation of silver nanoprisms (AgNPRs). Under natural sunlight illumination, the surface plasmon of AgNPRs is excited, which populates O 2 antibonding orbitals to generate negative-ion state (O 2 - ). The resultant O 2 - with a strong oxidation activity can etch AgNPRs to smaller nanodisks with the aid of NaOH aqueous solution, leading to a blue shift of the absorption peak and color change from blue to pink. However, when HTT is introduced, the resultant O 2 - will be consumed by the nitrite and formaldehyde that are produced from the alkaline hydrolysis of HTT. Under this condition, the etching of AgNPRs does not occur, and the detection solution remains blue. This assay can sensitively detect as low as 1nM HTT, a level which is three orders of magnitude lower than that of gold nanoparticle-based colorimetric assays (2.6μM), and shows linearity in the range of 0.003-3.3μM. The lowest detectable concentration with the naked eye is 0.1μM. Additionally, the present assay exhibits good selectivity, and can be applied in the detection of HTT in natural water and soil samples with recoveries ranging from 90% to 100%. Copyright © 2017 Elsevier B.V. All rights reserved.
Taghdisi, Seyed Mohammad; Danesh, Noor Mohammad; Ramezani, Mohammad; Emrani, Ahmad Sarreshtehdar; Abnous, Khalil
2018-04-18
Zearalenone (ZEN) toxicity is a significant risk for human beings. Thus, it is of high importance to develop sensitive, precise, and inexpensive analytical methods for ZEN detection, especially in human serum. Here, a colorimetric aptasensor is presented for the determination of ZEN based on the nontarget-induced aptamer walker, catalytic reaction of gold nanoparticles (AuNPs), exonuclease III (Exo III) as a signal amplifier, and 4-nitrophenol as a colorimetric agent. Low amount of ZEN requirement and signal amplification are some of the distinct advantages of the proposed aptasensor. In the absence of ZEN, the aptamer (Apt) starts walking on the AuNP surface with the help of Exo III and binds to multiple complementary strands of aptamer, leading to the change of sample color from yellow to colorless. Upon the addition of ZEN, both the Apt and complementary strand exist as single-stranded DNAs on the surface of AuNPs, resulting in less access of 4-nitrophenol to the surface of AuNPs and less catalytic performance of AuNPs. In this situation, the color of the sample remains yellow (the color of 4-nitrophenol). The presented aptasensor was capable to detect ZEN in a wide linear dynamic range, 20-80 000 ng/L, with a detection limit of 10 ng/L. The prepared sensing strategy was successfully used for ZEN determination in the human serum sample.
Multiplexed Paper Analytical Device for Quantification of Metals using Distance-Based Detection
Cate, David M.; Noblitt, Scott D.; Volckens, John; Henry, Charles S.
2015-01-01
Exposure to metal-containing aerosols has been linked with adverse health outcomes for almost every organ in the human body. Commercially available techniques for quantifying particulate metals are time-intensive, laborious, and expensive; often sample analysis exceeds $100. We report a simple technique, based upon a distance-based detection motif, for quantifying metal concentrations of Ni, Cu, and Fe in airborne particulate matter using microfluidic paper-based analytical devices. Paper substrates are used to create sensors that are self-contained, self-timing, and require only a drop of sample for operation. Unlike other colorimetric approaches in paper microfluidics that rely on optical instrumentation for analysis, with distance-based detection, analyte is quantified visually based on the distance of a colorimetric reaction, similar to reading temperature on a thermometer. To demonstrate the effectiveness of this approach, Ni, Cu, and Fe were measured individually in single-channel devices; detection limits as low as 0.1, 0.1, and 0.05 µg were reported for Ni, Cu, and Fe. Multiplexed analysis of all three metals was achieved with detection limits of 1, 5, and 1 µg for Ni, Cu, and Fe. We also extended the dynamic range for multi-analyte detection by printing concentration gradients of colorimetric reagents using an off the shelf inkjet printer. Analyte selectivity was demonstrated for common interferences. To demonstrate utility of the method, Ni, Cu, and Fe were measured from samples of certified welding fume; levels measured with paper sensors matched known values determined gravimetrically. PMID:26009988
Low-Cost Chemical-Responsive Adhesive Sensing Chips.
Tan, Weirui; Zhang, Liyuan; Shen, Wei
2017-12-06
Chemical-responsive adhesive sensing chip is a new low-cost analytical platform that uses adhesive tape loaded with indicator reagents to detect or quantify the target analytes by directly sticking the tape to the samples of interest. The chemical-responsive adhesive sensing chips can be used with paper to analyze aqueous samples; they can also be used to detect and quantify solid, particulate, and powder analytes. The colorimetric indicators become immediately visible as the contact between the functionalized adhesives and target samples is made. The chemical-responsive adhesive sensing chip expands the capability of paper-based analytical devices to analyze solid, particulate, or powder materials via one-step operation. It is also a simpler alternative way, to the covalent chemical modification of paper, to eliminate indicator leaching from the dipstick-style paper sensors. Chemical-responsive adhesive chips can display analytical results in the form of colorimetric dot patterns, symbols, and texts, enabling clear understanding of assay results by even nonprofessional users. In this work, we demonstrate the analyses of heavy metal salts in silica powder matrix, heavy metal ions in water, and bovine serum albumin in an aqueous solution. The detection is one-step, specific, sensitive, and easy-to-operate.
Nzelu, Chukwunonso O; Cáceres, Abraham G; Guerrero-Quincho, Silvia; Tineo-Villafuerte, Edwin; Rodriquez-Delfin, Luis; Mimori, Tatsuyuki; Uezato, Hiroshi; Katakura, Ken; Gomez, Eduardo A; Guevara, Angel G; Hashiguchi, Yoshihisa; Kato, Hirotomo
2016-01-01
Leishmaniasis remains one of the world's most neglected diseases, and early detection of the infectious agent, especially in developing countries, will require a simple and rapid test. In this study, we established a quick, one-step, single-tube, highly sensitive loop-mediated isothermal amplification (LAMP) assay for rapid detection of Leishmania DNA from tissue materials spotted on an FTA card. An FTA-LAMP with pre-added malachite green was performed at 64°C for 60min using a heating block and/or water bath and DNA amplification was detected immediately after incubation. The LAMP assay had high detection sensitivity down to a level of 0.01 parasites per μl. The field- and clinic-applicability of the colorimetric FTA-LAMP assay was demonstrated with 122 clinical samples collected from patients suspected of having cutaneous leishmaniasis in Peru, from which 71 positives were detected. The LAMP assay in combination with an FTA card described here is rapid and sensitive, as well as simple to perform, and has great potential usefulness for diagnosis and surveillance of leishmaniasis in endemic areas. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Savoy, Steven M.; Lavigne, John J.; Yoo, J. S.; Wright, John; Rodriguez, Marc; Goodey, Adrian; McDoniel, Bridget; McDevitt, John T.; Anslyn, Eric V.; Shear, Jason B.; Ellington, Andrew D.; Neikirk, Dean P.
1998-12-01
A micromachined sensor array has been developed for the rapid characterization of multi-component mixtures in aqueous media. The sensor functions in a manner analogous to that of the mammalian tongue, using an array composed of individually immobilized polystyrene-polyethylene glycol composite microspheres selectively arranged in micromachined etch cavities localized o n silicon wafers. Sensing occurs via colorimetric or fluorometric changes to indicator molecules that are covalently bound to amine termination sites on the polymeric microspheres. The hybrid micromachined structure has been interfaced directly to a charged-coupled-device that is used for the simultaneous acquisition of the optical data from the individually addressable `taste bud' elements. With the miniature sensor array, acquisition of data streams composed of red, green, and blue color patterns distinctive for the analytes in the solution are rapidly acquired. The unique combination of carefully chosen reporter molecules with water permeable microspheres allows for the simultaneous detection and quantification of a variety of analytes. The fabrication of the sensor structures and the initial colorimetric and fluorescent responses for pH, Ca+2, Ce+3, and sugar are reported. Interface to microfluidic components should also be possible, producing a complete sampling/sensing system.
ERIC Educational Resources Information Center
Wang, Bo; Lin, Zhiqiang; Wang, Min
2015-01-01
Paper-based microfluidic devices (µPAD) are a burgeoning platform of microfluidic analysis technology. The method described herein is for use in undergraduate and high school chemistry laboratories. A simple and convenient µPAD was fabricated by easy patterning of filter paper using a permanent marker pen. The usefulness of the device was…
Graphene quantum dot as a green and facile sensor for free chlorine in drinking water.
Dong, Yongqiang; Li, Geli; Zhou, Nana; Wang, Ruixue; Chi, Yuwu; Chen, Guonan
2012-10-02
Free chlorine was found to be able to destroy the passivated surface of the graphene quantum dots (GQDs) obtained by pyrolyzing citric acid, resulting in significant quenching of their fluorescence (FL) signal. After optimizing some experimental conditions (including response time, concentration of GQDs, and pH value of solution), a green and facile sensing system has been developed for the detection of free residual chlorine in water based on FL quenching of GQDs. The sensing system exhibits many advantages, such as short response time, excellent selectivity, wide linear response range, and high sensitivity. The linear response range of free chlorine (R(2) = 0.992) was from 0.05 to 10 μM. The detection limit (S/N = 3) was as low as 0.05 μM, which is much lower than that of the most widely used N-N-diethyl-p-phenylenediamine (DPD) colorimetric method. This sensing system was finally used to detect free residual chlorine in local tap water samples. The result agreed well with that by the DPD colorimetric method, suggesting the potential application of this new, green, sensitive, and facile sensing system in drinking water quality monitoring.
Salivary analytes in patients with oral squamous cell carcinoma.
Fuchs, Petra Nola; Rogić, Dunja; Vidović-Juras, Danica; Susić, Mato; Milenović, Aleksandar; Brailo, Vlaho; Boras, Vanja Vucićević
2011-06-01
Literature data indicates that measurement of certain salivary constituents might serve as a useful diagnostic/prognostic tool in the patients with oral squamous cell carcinoma (OSCC). In 24 patients with OSCC (60 +/- 2.5 yrs) and in 24 controls (24 +/- 3.7 yrs) we have determined levels of salivary magnesium, calcium, copper, chloride, phosphate, potassium, sodium, total proteins and amylase. Sodium, potassium and chloride were determined by indirect potentiometry whereas copper, magnesium and phosphate were determined by atomic absorption spectrophotometry. Total proteins were determined by pyrogalol colorimetric method. Amylase levels were determined by continued colorimetric method. Statistical analysis was performed by use of chi2 test and Spearman's correlation test. The results of this study indicate that the concentrations of sodium and chloride were significantly elevated in patients with OSCC when compared to the controls. However, level of total protein was significantly decreased when compared to the healthy controls. Furthermore, there was a negative correlation between alcohol consumption and total protein concentration in patients with oral carcinoma. We might conclude that in patients with OSCC increased salivary sodium and chloride might reflect their overall dehydration status due to alcohol consumption rather than consequence of OSCC itself.
Cheon, Ja Young; Park, Won Ho
2016-01-01
This articles reports a simple and green method for preparing uniform silver nanoparticles (AgNPs), for which self-polymerized 3,4-dihydroxy-l-phenylalanine (polyDOPA) is used as the reducing and stabilizing agent in aqueous media. The AgNPs functionalized by polyDOPA were analyzed by UV–Vis spectroscopy, high-resolution transmission electron microscopy (HR-TEM), Fourier transform infrared spectroscopy (FT-IR), thermogravimetric analysis (TGA), Raman spectrophotometry, and X-ray diffraction (XRD) techniques. The results revealed that the polyDOPA-AgNPs with diameters of 25 nm were well dispersed due to the polyDOPA. It was noted that the polyDOPA-AgNPs showed selectivity for Pb2+ and Cu2+ detection with the detection limits for the two ions as low as 9.4 × 10−5 and 8.1 × 10−5 μM, respectively. Therefore, the polyDOPA-AgNPs can be applied to both Pb2+ and Cu2+ detection in real water samples. The proposed method will be useful for colorimetric detection of heavy metal ions in aqueous media. PMID:27916894
NASA Astrophysics Data System (ADS)
Di, Weihua; Zhang, Xiang; Qin, Weiping
2017-04-01
The rapid, sensitive and selective detection of glutathione (GSH) is of great importance in the biological systems. In this work, a template-free and one-step method was used to synthesize the single-layer MnO2 nanosheets via a redox reaction. The resulting product was characterized by XRD, TEM, FTIR, XPS and UV-vis absorption. The addition of GSH results in the change of solution color depth owing to the occurrence of a redox reaction between MnO2 and GSH, enabling colorimetric detection of GSH. At a pH of 3.6, the proposed sensor gives a linear calibration over a GSH concentration range of 10-100 μM, with a rapid response of less than 2 min and a low detection limit of 0.5 μM. The relative standard deviation for seven repeated determinations of GSH is lower than 5.6%. Furthermore, the chemical response of the synthesized MnO2 nanosheets toward GSH is selective. Owing to the advantages with good water solubility, rapid response, high sensitivity, good biocompatibility and operation simplicity, this two-dimensional MnO2-based sensing material might be potential for detecting GSH in biological applications.
Photoacoustic and Colorimetric Visualization of Latent Fingerprints.
Song, Kai; Huang, Peng; Yi, Chenglin; Ning, Bo; Hu, Song; Nie, Liming; Chen, Xiaoyuan; Nie, Zhihong
2015-12-22
There is a high demand on a simple, rapid, accurate, user-friendly, cost-effective, and nondestructive universal method for latent fingerprint (LFP) detection. Herein, we describe a combination imaging strategy for LFP visualization with high resolution using poly(styrene-alt-maleic anhydride)-b-polystyrene (PSMA-b-PS) functionalized gold nanoparticles (GNPs). This general approach integrates the merits of both colorimetric imaging and photoacoustic imaging. In comparison with the previous methods, our strategy is single-step and does not require the signal amplification by silver staining. The PSMA-b-PS functionalized GNPs have good stability, tunable color, and high affinity for universal secretions (proteins/polypeptides/amino acids), which makes our approach general and flexible for visualizing LFPs on different substrates (presumably with different colors) and from different people. Moreover, the unique optical property of GNPs enables the photoacoustic imaging of GNPs-deposited LFPs with high resolution. This allows observation of level 3 hyperfine features of LFPs such as the pores and ridge contours by photoacoustic imaging. This technique can potentially be used to identify chemicals within LFP residues. We believe that this dual-modality imaging of LFPs will find widespread use in forensic investigations and medical diagnostics.
Sensitive method to monitor trace quantities of benzanthrone in workers of dyestuff industries
DOE Office of Scientific and Technical Information (OSTI.GOV)
Joshi, A.; Khanna, S.K.; Singh, G.B.
1986-03-01
Dyestuff workers coming in contact with benzanthrone (an intermediate used for the synthesis of a variety of dyes) develop skin lesions, gastritis, liver malfunctions, and sexual disturbances. A highly sensitive fluorometric method to monitor trace quantities of benzanthrone in urine, serum, and biological tissues for experimental studies, has been developed. Coupled with simple extraction and resolution, optimum fluorescence is obtained in an equal mixture of chloroform:methanol, detecting as low as 2 ng benzanthrone. This method is approximately 250 times more sensitive than currently available colorimetric assay.
Evaluation of cotton-fabric bleaching using hydrogen peroxide and Blue LED
NASA Astrophysics Data System (ADS)
de Oliveira, Bruno P.; Moriyama, Lilian T.; Bagnato, Vanderlei S.
2015-06-01
The raw cotton production requires multiple steps being one of them the removal of impurities acquired during previous processes. This procedure is widely used by textile industries around the world and is called bleaching. The raw cotton is composed by cellulosic and non-cellulosic materials like waxes, pectins and oils, which are responsible for its characteristic yellowish color. The bleaching process aims to remove the non-cellulosic materials concentration in the fabric, increasing its whiteness degree. The most used bleaching method utilizes a bath in an alkali solution of hydrogen peroxide, stabilizers and buffer solutions under high temperature. In the present study we evaluated the possibility of using a blue illumination for the bleaching process. We used blue LEDs (450 nm) to illuminate an acid hydrogen peroxide solution at room temperature. The samples treated by this method were compared with the conventional bleaching process through a colorimetric analysis and by a multiple comparison visual inspection by volunteers. The samples were also studied by a tensile test in order to verify the integrity of the cloth after bleaching. The results of fabric visual inspection and colorimetric analysis showed a small advantage for the sample treated by the standard method. The tensile test showed an increasing on the yield strength of the cloth after blue light bleaching. The presented method has great applicability potential due to the similar results compared to the standard method, with relative low cost and reduced production of chemical waste.
A colorimetric sensor array for identification of toxic gases below permissible exposure limits†
Feng, Liang; Musto, Christopher J.; Kemling, Jonathan W.; Lim, Sung H.; Suslick, Kenneth S.
2010-01-01
A colorimetric sensor array has been developed for the rapid and sensitive detection of 20 toxic industrial chemicals (TICs) at their PELs (permissible exposure limits). The color changes in an array of chemically responsive nanoporous pigments provide facile identification of the TICs with an error rate below 0.7%. PMID:20221484
Singh, Rohit Kumar; Mishra, Sourav; Jena, Satyapriya; Panigrahi, Bijayananda; Das, Bhaskar; Jayabalan, Rasu; Parhi, Pankaj Kumar; Mandal, Dindyal
2018-04-17
Polyphenol functionalized silver nanoparticles (AgNPs) have been developed and demonstrated as colorimetric sensors for the selective detection of gadolinium. The newly obtained AgNP-Gd3+ conjugates exhibit high aqueous dispersibility and excitation dependent fluorescence emission. The conjugates offer multicolor bioimaging potential owing to their excellent luminescence properties.
Yang, Zhenghao; Liu, Zhipeng; Chen, Yuncong; Wang, Xiaoqing; He, Weijiang; Lu, Yi
2012-07-14
A hybrid coumarin-hemicyanine dye, Cou-BT, was developed as a new ratiometric and colorimetric sensor for cyanide with a sensing mechanism via nucleophilic addition of cyanide anion to the benzothiolium group. Cou-BT shows high sensitivity and selectivity for cyanide detection over other common anion species in aqueous acetonitrile solution. The calculated pseudo-first-order rate constant for cyanide anion addition was (2.13 ± 0.08) × 10(-2) s(-1) at 298 K, and the detection limit was estimated to be 0.64 μM. The DFT and TDDFT calculation results suggest that the ratiometric and colorimetric sensing behavior of Cou-BT upon its reaction with cyanide was due to the interrupted π-conjugation and blocked ICT progress.
A new azine derivative colorimetric and fluorescent dual-channel probe for cyanide detection
NASA Astrophysics Data System (ADS)
Yu, Bin; Li, Chun-Yu; Sun, Yin-Xia; Jia, Hao-Ran; Guo, Jian-Qiang; Li, Jing
2017-09-01
A novel azine derivative colorimetric and fluorescent dual-channel probe salicylaldehyde hydrazine-3,5-dibromosalicylaldehyde (1) has been designed, synthesized and characterized. The probe 1 is confirmed to have especial selectivity and good sensitivity on detecting CN- via UV-vis absorption and fluorescence spectrum in aqueous solution (H2O/DMSO, 1:4, v/v). This colorimetric and fluorescent dual-channel probe response to CN- owed to the deprotonation process and established the mechanism by using 1H NMR spectroscopy. Further researches showed that the detection limit of the probe 1 to CN- anions is 8.01 × 10- 9 M, significantly lower than the maximum level 1.9 × 10- 6 M in potable water from WHO guidelines.
Absolute colorimetric characterization of a DSLR camera
NASA Astrophysics Data System (ADS)
Guarnera, Giuseppe Claudio; Bianco, Simone; Schettini, Raimondo
2014-03-01
A simple but effective technique for absolute colorimetric camera characterization is proposed. It offers a large dynamic range requiring just a single, off-the-shelf target and a commonly available controllable light source for the characterization. The characterization task is broken down in two modules, respectively devoted to absolute luminance estimation and to colorimetric characterization matrix estimation. The characterized camera can be effectively used as a tele-colorimeter, giving an absolute estimation of the XYZ data in cd=m2. The user is only required to vary the f - number of the camera lens or the exposure time t, to better exploit the sensor dynamic range. The estimated absolute tristimulus values closely match the values measured by a professional spectro-radiometer.
A novel reflectance-based aptasensor using gold nanoparticles for the detection of oxytetracycline.
Seo, Ho Bin; Kwon, Young Seop; Lee, Ji-eun; Cullen, David; Noh, Hongseok Moses; Gu, Man Bock
2015-10-07
We present a novel reflectance-based colorimetric aptasensor using gold nanoparticles for the detection of oxytetracycline for the first time. It was found that the reflectance-based measurement at two wavelengths (650 and 520 nm) can generate more stable and sensitive signals than absorbance-based sensors to determine the aggregation of AuNPs, even at high AuNP concentrations. One of the most common antibacterial agents, oxytetracycline (OTC), was detected at concentrations as low as 1 nM in both buffer solution and tap water, which was 25-fold more sensitive, compared to the previous absorbance-based colorimetric aptasensors. This reflectance-based colorimetric aptasensor using gold nanoparticles is considered to be a better platform for portable sensing of small molecules using aptamers.
NASA Astrophysics Data System (ADS)
Zhang, Lufeng; Du, Jianxiu
2016-04-01
The development of highly selective and sensitive method for iron(III) detection is of great importance both from human health as well as environmental point of view. We herein reported a simple, selective and sensitive colorimetric method for the detection of Fe(III) at submicromolar level with 3,3,‧5,5‧-tetramethylbenzidine (TMB) as a chromogenic probe. It was observed that Fe(III) could directly oxidize TMB to form a blue solution without adding any extra oxidants. The reaction has a stoichiometric ratio of 1:1 (Fe(III)/TMB) as determined by a molar ratio method. The resultant color change can be perceived by the naked eye or monitored the absorbance change at 652 nm. The method allowed the measurement of Fe(III) in the range 1.0 × 10- 7-1.5 × 10- 4 mol L- 1 with a detection limit of 5.5 × 10- 8 mol L- 1. The relative standard deviation was 0.9% for eleven replicate measurements of 2.5 × 10- 5 mol L- 1 Fe(III) solution. The chemistry showed high selectivity for Fe(III) in contrast to other common cation ions. The practically of the method was evaluated by the determination of Fe in milk samples; good consistency was obtained between the results of this method and atomic absorption spectrophotometry as indicated by statistical analysis.
Misra, Biswapriya B; Dey, Satyahari
2013-02-01
Sandalwood oil, rich in sesquiterpenoid alcohols, has been used in traditional medicinal systems as a relaxant and coolant. Besides, sandalwood oil is used as an ingredient in numerous skin fairness enhancing cosmetics. However, there is no available information on biological activities that relate to the above applications. Hence, the anti-tyrosinase and anti-cholinesterase potentials of sandalwood oil were probed by both TLC-bioautographic and colorimetric methods. Results obtained from colorimetric assays indicated that sandalwood oil is a potent inhibitor of tyrosinase (IC50 = 171 microg mL(-1)) and cholinesterases (IC50 = 4.8-58 microg mL(-1)), in comparison with the positive controls used in the assays, kojic acid and physostigmine, respectively. The TLC-bioautographic assays indicated that alpha-santalol, the major constituent of the oil, is a strong inhibitor of both tyrosinase and cholinesterase. These in vitro results indicate that there is a great potential of this essential oil for use in the treatment of Alzheimer's disease, as well as in skin-care.
Colorimetric detection of copper in water using a Schiff base derivative
NASA Astrophysics Data System (ADS)
Peralta Domínguez, D.; Ramos-Ortiz, G.; Maldonado, J. L.; Rodriguez, M.; Meneses-Nava, M. A.; Barbosa-Garcia, O.; Santillan, R.; Farfán, N.
2013-09-01
Organic molecular sensors have the advantage of being used through an easy, fast, economical and reliable optical method for detecting toxic metal ions in our environment. In this work, we present a simple but highly specific organic ligand compound 5-Chloro-2-((E)-((E)-3-(4-(dimethylamino)phenyl)allylidene)amino)phenol (L1) that acts as a colorimetric sensor for ions in a mixture of acetonitrile/water (ratio 10:1, v:v). Binding interaction between L1 and various metal-ions has been established by ultraviolet-visible spectroscopic measurements that indicate favorable coordination of the ligand with selective metal ions, particularly, with copper. These results showed that the electronic transition band shape of L1 change after binding with copper in aqueous solution. L1 exhibited binding-induced color changes from yellow to pink one detected by the naked eye. This new sensor presented 2.5 × 10-6 M as limit detection, even under the presence of other metal ions.
Jaafar, Shoffian Amin; Latif, Mohd Talib; Chian, Chong Woan; Han, Wong Sook; Wahid, Nurul Bahiyah Abd; Razak, Intan Suraya; Khan, Md Firoz; Tahir, Norhayati Mohd
2014-07-15
This study was conducted to determine the composition of surfactants in the sea-surface microlayer (SML) and atmospheric aerosol around the southern region of the Peninsular Malaysia. Surfactants in samples taken from the SML and atmospheric aerosol were determined using a colorimetric method, as either methylene blue active substances (MBAS) or disulphine blue active substances (DBAS). Principal component analysis with multiple linear regressions (PCA-MLR), using the anion and major element composition of the aerosol samples, was used to determine possible sources of surfactants in atmospheric aerosol. The results showed that the concentrations of surfactants in the SML and atmospheric aerosol were dominated by anionic surfactants and that surfactants in aerosol were not directly correlated (p>0.05) with surfactants in the SML. Further PCA-MLR from anion and major element concentrations showed that combustion of fossil fuel and sea spray were the major contributors to surfactants in aerosol in the study area. Copyright © 2014 Elsevier Ltd. All rights reserved.
Solt, M W; Wahlberg, J S; Myers, A T
1969-01-01
Rhenium in molybdenite is separated from molybdenum by distillation of rhenium heptoxide from a perchloric-sulphuric acid mixture. It is concentrated by precipitation of the sulphide and then determined by X-ray fluorescence. From 3 to 1000 microg of rhenium can be measured with a precision generally within 2%. The procedure tolerates larger amounts of molybdenum than the usual colorimetric methods.
1984-03-01
a....... .6 Thin Layer Chromatographic (TLC) Analyses... o................. ......a... 7 RESULTS AND DISCUSSIONo.....................o...Beckman 5230 UV/visible spectrophotometer was used for colorimetric determinations of urea and cyanamide. Urea was hydrolyzed by urease and...correlation coefficients were 0.9999. THIN LAYER CHROMATOGRAPHIC (TLC) ANALYSES Cellulose plates were used and were developed in the following systems: 3N
Ghorai, Anupam; Mondal, Jahangir; Chandra, Rukmani; Patra, Goutam K
2015-08-07
A reversible fluorescent-colorimetric imino-pyridyl bis-Schiff base receptor (N(1)E,N(4)E)-N(1),N(4)-bis(pyridine-4-ylmethylene)benzene-1,4-diamine for the detection of both Al(3+) and HSO3(-) in aqueous medium has been developed. Receptor exhibits an excellent selective fluorescent-colorimetric response toward Al(3+). The sensitivity of the fluorescent based assay (0.903 μM) for Al(3+) is far below the limit recommended in the World Health Organization (WHO) guidelines for drinking water (7.41 μM). From (1)H NMR data, the Job plot and the ESI-MS spectrum, 1 : 2 stoichiometric complexation between and Al(3+) has been established. Receptor shows remarkable detection ability in a wide pH range of 4-11 and was successfully utilised in the determination of Al(3+) in aqueous solution of bovine serum albumin protein, and of HSO3(-) in real food samples. Moreover, shows a highly selective colorimetric response to HSO3(-) by changing its colour from yellow to colorless immediately without any interference from other anions.
Design of a colorimetric sensing platform using reflection mode plasmonic colour filters
NASA Astrophysics Data System (ADS)
Mudachathi, Renilkumar; Tanaka, Takuo
2017-08-01
Plasmonic nano structures fabricated using inexpensive and abundant aluminum metal shows intense narrow reflection peaks with strong response to the external stimuli, provides a simple yet powerful detection mechanism that is well suited for the development of low cost and low power sensors, such as colorimetric sensors, which transduces external stimuli or environmental changes in to visible colour changes. Such low cost and disposable sensors have huge demands in the point-of-care and home health care diagnostic applications. We present the design of a colorimetric sensing platform based on reflection mode plasmonic colour filters on both silicon and glass substrate, which demonstrate a sharp colour change for varying ambient refractive index. The sensor is essentially a plasmonic metamaterial in which the aluminum square plate hovering on a PMMA nano pillar in the background of a perforated aluminum reflector forms the unit cell which is arranged periodically in a 2D square lattice. The meta-surface has two distinct absorption peaks in the visible region leaving a strong reflection band, which strongly responds to the ambient refractive index change, provides a means for the realization of low cost colorimetric sensing platform.
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Schultz, John R.; Clarke, Mark S.
2007-01-01
Phase separation is one of the most significant obstacles encountered during the development of analytical methods for water quality monitoring in spacecraft environments. Removing air bubbles from water samples prior to analysis is a routine task on earth; however, in the absence of gravity, this routine task becomes extremely difficult. This paper details the development and initial ground testing of liquid metering centrifuge sticks (LMCS), devices designed to collect and meter a known volume of bubble-free water in microgravity. The LMCS uses centrifugal force to eliminate entrapped air and reproducibly meter liquid sample volumes for analysis with Colorimetric Solid Phase Extraction (C-SPE). C-SPE is a sorption-spectrophotometric platform that is being developed as a potential spacecraft water quality monitoring system. C-SPE utilizes solid phase extraction membranes impregnated with analyte-specific colorimetric reagents to concentrate and complex target analytes in spacecraft water samples. The mass of analyte extracted from the water sample is determined using diffuse reflectance (DR) data collected from the membrane surface and an analyte-specific calibration curve. The analyte concentration can then be calculated from the mass of extracted analyte and the volume of the sample analyzed. Previous flight experiments conducted in microgravity conditions aboard the NASA KC-135 aircraft demonstrated that the inability to collect and meter a known volume of water using a syringe was a limiting factor in the accuracy of C-SPE measurements. Herein, results obtained from ground based C-SPE experiments using ionic silver as a test analyte and either the LMCS or syringes for sample metering are compared to evaluate the performance of the LMCS. These results indicate very good agreement between the two sample metering methods and clearly illustrate the potential of utilizing centrifugal forces to achieve phase separation and metering of water samples in microgravity.
Wu, Tzu-Heng; Chang, Chia-Chen; Vaillant, Julien; Bruyant, Aurélien; Lin, Chii-Wann
2016-11-15
Smartphone camera based gold nanoparticle colorimetry (SCB-AuNP colorimetry) has shown good potential for point-of-care applications. However, due to the use of a camera as a photo-detector, there are major limitations to this technique such as a low bit resolution (∼8 bits mainstream) and a low data acquisition rate. These issues have limited the ultimate sensitivity of smartphone based colorimetry as well as the possibility to integrate efficiently a more sensitive approach such as detection based on a lock-in amplifier (LIA). In this paper, we improve the metrological performance of the smartphone to overcome existing issues by adding the LIA capability to AuNP sensing. In this work, instead of using the camera as a photo-detector, the audio jack is used as a photo-detector reader and function generator for driving a laser diode in order to achieve a smartphone based digital lock-in amplifier AuNP colorimetric (SBLIA-AuNP colorimetry) system. A full investigation on the SBLIA design, parameters and performance is comprehensively provided. It is found that the SBLIA can reduce most of the noise and provides a detection noise-to-signal ratio down to -63 dB, which is much better than the -49 dB of the state-of-the-art SCB based method. A DNA detection experiment is demonstrated to reveal the efficacy of the proposed metrological method. The results are compared to UV-visible spectrometry, which is the gold standard for colorimetric measurement. Based on our results, the SBLIA-AuNP colorimetric system has a detection limit of 0.77 nM on short strand DNA detection, which is 5.7 times better than the 4.36 nM limit of a commercial UV-visible spectrometer. Judging from the results, we believe that the sensitive SBLIA would be further extended to other optical diagnostic tools in the near future.
Jasim, B; Jimtha John, C; Shimil, V; Jyothis, M; Radhakrishnan, E K
2014-09-01
The study mainly aimed quantitative analysis of IAA produced by endophytic bacteria under various conditions including the presence of extract from Piper nigrum. Analysis of genetic basis of IAA production was also conducted by studying the presence and diversity of the ipdc gene among the selected isolates. Five endophytic bacteria isolated previously from P. nigrum were used for the study. The effect of temperature, pH, agitation, tryptophan concentration and plant extract on modulating IAA production of selected isolates was analysed by colorimetric method. Comparative and quantitative analysis of IAA production by colorimetric isolates under optimal culture condition was analysed by HPTLC method. Presence of ipdc gene and thereby biosynthetic basis of IAA production among the selected isolates were studied by PCR-based amplification and subsequent insilico analysis of sequence obtained. Among the selected bacterial isolates from P. nigrum, isolate PnB 8 (Klebsiella pneumoniae) was found to have the maximum yield of IAA under various conditions optimized and was confirmed by colorimetric, HPLC and HPTLC analysis. Very interestingly, the study showed stimulating effect of phytochemicals from P. nigrum on IAA production by endophytic bacteria isolated from same plant. This study is unique because of the selection of endophytes from same source for comparative and quantitative analysis of IAA production under various conditions. Study on stimulatory effect of phytochemicals on bacterial IAA production as explained in the study is a novel approach. Studies on molecular basis of IAA production which was confirmed by sequence analysis of ipdc gene make the study scientifically attractive. Even though microbial production of IAA is well known, current report on detailed optimization, effect of plant extract and molecular confirmation of IAA biosynthesis is comparatively novel in its approach. © 2014 The Society for Applied Microbiology.
Fedenko, Volodymyr S; Shemet, Sergiy A; Landi, Marco
2017-05-01
Although anthocyanin (ACN) biosynthesis is one of the best studied pathways of secondary metabolism in plants, the possible physiological and ecological role(s) of these pigments continue to intrigue scientists. Like other dihydroxy B-ring substituted flavonoids, ACNs have an ability to bind metal and metalloid ions, a property that has been exploited for a variety of purposes. For example, the metal binding ability may be used to stabilize ACNs from plant food sources, or to modify their colors for using them as food colorants. The complexation of metals with cyanidin derivatives can also be used as a simple, sensitive, cheap, and rapid method for determination concentrations of several metals in biological and environmental samples using UV-vis spectroscopy. Far less information is available on the ecological significance of ACN-metal complexes in plant-environment interactions. Metalloanthocyanins (protocyanin, nemophilin, commelinin, protodelphin, cyanosalvianin) are involved in the copigmentation phenomenon that leads to blue-pigmented petals, which may facilitate specific plant-pollinator interactions. ACN-metal formation and compartmentation into the vacuole has also been proposed to be part of an orchestrated detoxification mechanism in plants which experience metal/metalloid excess. However, investigations into ACN-metal interactions in plant biology may be limited because of the complexity of the analytical techniques required. To address this concern, here we describe simple methods for the detection of ACN-metal both in vitro and in vivo using UV-vis spectroscopy and colorimetric models. In particular, the use of UV-vis spectra, difference absorption spectra, and colorimetry techniques will be described for in vitro determination of ACN-metal features, whereas reflectance spectroscopy and colorimetric parameters related to CIE L * a * b * and CIE XYZ systems will be detailed for in vivo analyses. In this way, we hope to make this high-informative tool more accessible to plant physiologists and ecologists. Copyright © 2017 Elsevier GmbH. All rights reserved.
Ludtke, Amy S.; Woodworth, Mark T.; Marsh, Philip S.
2000-01-01
The U.S. Geological Survey operates a quality-assurance program based on the analyses of reference samples for two laboratories: the National Water Quality Laboratory and the Quality of Water Service Unit. Reference samples that contain selected inorganic, nutrient, and low-level constituents are prepared and submitted to the laboratory as disguised routine samples. The program goal is to estimate precision and bias for as many analytical methods offered by the participating laboratories as possible. Blind reference samples typically are submitted at a rate of 2 to 5 percent of the annual environmental-sample load for each constituent. The samples are distributed to the laboratories throughout the year. The reference samples are subject to the identical laboratory handling, processing, and analytical procedures as those applied to environmental samples and, therefore, have been used as an independent source to verify bias and precision of laboratory analytical methods and ambient water-quality measurements. The results are stored permanently in the National Water Information System and the Blind Sample Project's data base. During water year 1998, 95 analytical procedures were evaluated at the National Water Quality Laboratory and 63 analytical procedures were evaluated at the Quality of Water Service Unit. An overall evaluation of the inorganic and low-level constituent data for water year 1998 indicated 77 of 78 analytical procedures at the National Water Quality Laboratory met the criteria for precision. Silver (dissolved, inductively coupled plasma-mass spectrometry) was determined to be imprecise. Five of 78 analytical procedures showed bias throughout the range of reference samples: chromium (dissolved, inductively coupled plasma-atomic emission spectrometry), dissolved solids (dissolved, gravimetric), lithium (dissolved, inductively coupled plasma-atomic emission spectrometry), silver (dissolved, inductively coupled plasma-mass spectrometry), and zinc (dissolved, inductively coupled plasma-mass spectrometry). At the National Water Quality Laboratory during water year 1998, lack of precision was indicated for 2 of 17 nutrient procedures: ammonia as nitrogen (dissolved, colorimetric) and orthophosphate as phosphorus (dissolved, colorimetric). Bias was indicated throughout the reference sample range for ammonia as nitrogen (dissolved, colorimetric, low level) and nitrate plus nitrite as nitrogen (dissolved, colorimetric, low level). All analytical procedures tested at the Quality of Water Service Unit during water year 1998 met the criteria for precision. One of the 63 analytical procedures indicated a bias throughout the range of reference samples: aluminum (whole-water recoverable, inductively coupled plasma-atomic emission spectrometry, trace).
Wu, Yuanyuan; Boonloed, Anukul; Sleszynski, Neal; Koesdjojo, Myra; Armstrong, Chadd; Bracha, Shay; Remcho, Vincent T
2015-08-25
Rapidly increasing healthcare costs in economically advantaged countries are currently unsustainable, while in many developing nations, even 50-year-old technologies are too expensive to implement. New and unconventional technologies are being explored as solutions to this problem. In this study, we examined the use of a smartphone as the detection platform for 2 well-developed, relatively inexpensive, commercially available clinical chemistry assays as a model for rapid and inexpensive clinical diagnostic testing. An Apple iPhone 4 camera phone equipped with a color analysis application (ColorAssist) was combined with Vitros® glucose and urea colorimetric assays. Color images of assay slides at various concentrations of glucose or urea were collected with the iPhone 4 and quantitated in three different spectral ranges (red/green/blue or RGB) using the ColorAssist app. When the diffuse reflectance data was converted into absorbance, it was possible to quantitate glucose or blood urea nitrogen (BUN) over their clinically important concentration ranges (30-515mg/dl for glucose or 2-190mg/dl for BUN), with good linearity (R(2)=0.9994 or 0.9996, respectively [n=5]). Data collected using the iPhone 4 and canine serum samples were in agreement with results from the instrumental "gold standard" (Beckman Coulter AU480 Chemistry System) (R(2)=0.9966 and slope=1.0001 for glucose; R(2)=0.9958 and slope=0.9454 for BUN). Glucose determinations of serum samples made using this smartphone method were as accurate as or more accurate than a commercial colorimetric dry slide analyzer (Heska® Element DC Chemistry Analyzer, Loveland, CO) and 2 glucometers: ReliOn® Ultima (Abbott Diabetes Care Inc) and Presto® (AgaMatrix Inc.H). BUN determinations made using the smartphone approach were comparable in accuracy to the Heska instrument. This demonstration shows that smartphones have the potential to be used as simple, effective colorimetric detectors for quantitative diagnostic tests, and may be applicable for both point-of-care applications in the developed world and field deployment in developing nations. Copyright © 2015 Elsevier B.V. All rights reserved.
High-Throughput Screening Assay for Laccase Engineering toward Lignosulfonate Valorization
Rodríguez-Escribano, David; de Salas, Felipe; Camarero, Susana
2017-01-01
Lignin valorization is a pending issue for the integrated conversion of lignocellulose in consumer goods. Lignosulfonates (LS) are the main technical lignins commercialized today. However, their molecular weight should be enlarged to meet application requirements as additives or dispersing agents. Oxidation of lignosulfonates with fungal oxidoreductases, such as laccases, can increase the molecular weight of lignosulfonates by the cross-linking of lignin phenols. To advance in this direction, we describe here the development of a high-throughput screening (HTS) assay for the directed evolution of laccases, with lignosulfonate as substrate and the Folin–Ciocalteau reagent (FCR), to detect the decrease in phenolic content produced upon polymerization of lignosulfonate by the enzyme. Once the reaction conditions were adjusted to the 96-well-plate format, the enzyme for validating the assay was selected from a battery of high-redox-potential laccase variants functionally expressed in S. cerevisiae (the preferred host for the directed evolution of fungal oxidoreductases). The colorimetric response (absorbance at 760 nm) correlated with laccase activity secreted by the yeast. The HTS assay was reproducible (coefficient of variation (CV) = 15%) and sensitive enough to detect subtle differences in activity among yeast clones expressing a laccase mutant library obtained by error-prone PCR (epPCR). The method is therefore feasible for screening thousands of clones during the precise engineering of laccases toward valorization of lignosulfonates. PMID:28820431
High-Throughput Screening Assay for Laccase Engineering toward Lignosulfonate Valorization
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rodriguez-Escribano, David; de Salas, Felipe; Pardo, Isabel
Lignin valorization is a pending issue for the integrated conversion of lignocellulose in consumer goods. Lignosulfonates (LS) are the main technical lignins commercialized today. However, their molecular weight should be enlarged to meet application requirements as additives or dispersing agents. Oxidation of lignosulfonates with fungal oxidoreductases, such as laccases, can increase the molecular weight of lignosulfonates by the cross-linking of lignin phenols. To advance in this direction, we describe here the development of a high-throughput screening (HTS) assay for the directed evolution of laccases, with lignosulfonate as substrate and the Folin-Ciocalteau reagent (FCR), to detect the decrease in phenolic contentmore » produced upon polymerization of lignosulfonate by the enzyme. Once the reaction conditions were adjusted to the 96-well-plate format, the enzyme for validating the assay was selected from a battery of high-redox-potential laccase variants functionally expressed in S. cerevisiae (the preferred host for the directed evolution of fungal oxidoreductases). The colorimetric response (absorbance at 760 nm) correlated with laccase activity secreted by the yeast. The HTS assay was reproducible (coefficient of variation (CV) = 15%) and sensitive enough to detect subtle differences in activity among yeast clones expressing a laccase mutant library obtained by error-prone PCR (epPCR). As a result, the method is therefore feasible for screening thousands of clones during the precise engineering of laccases toward valorization of lignosulfonates.« less
High-Throughput Screening Assay for Laccase Engineering toward Lignosulfonate Valorization
Rodriguez-Escribano, David; de Salas, Felipe; Pardo, Isabel; ...
2017-08-18
Lignin valorization is a pending issue for the integrated conversion of lignocellulose in consumer goods. Lignosulfonates (LS) are the main technical lignins commercialized today. However, their molecular weight should be enlarged to meet application requirements as additives or dispersing agents. Oxidation of lignosulfonates with fungal oxidoreductases, such as laccases, can increase the molecular weight of lignosulfonates by the cross-linking of lignin phenols. To advance in this direction, we describe here the development of a high-throughput screening (HTS) assay for the directed evolution of laccases, with lignosulfonate as substrate and the Folin-Ciocalteau reagent (FCR), to detect the decrease in phenolic contentmore » produced upon polymerization of lignosulfonate by the enzyme. Once the reaction conditions were adjusted to the 96-well-plate format, the enzyme for validating the assay was selected from a battery of high-redox-potential laccase variants functionally expressed in S. cerevisiae (the preferred host for the directed evolution of fungal oxidoreductases). The colorimetric response (absorbance at 760 nm) correlated with laccase activity secreted by the yeast. The HTS assay was reproducible (coefficient of variation (CV) = 15%) and sensitive enough to detect subtle differences in activity among yeast clones expressing a laccase mutant library obtained by error-prone PCR (epPCR). As a result, the method is therefore feasible for screening thousands of clones during the precise engineering of laccases toward valorization of lignosulfonates.« less
Colorimetric microdetermination of captopril in pure form and in pharmaceutical formulations
NASA Astrophysics Data System (ADS)
Shama, Sayed Ahmed; El-Sayed Amin, Alla; Omara, Hany
2006-11-01
A simple, rapid, accurate, precise and sensitive colorimetric method for the determination of captopril (CAP) in bulk sample and in dosage forms is described. The method is based on oxidation of the drug by potassium permanganate in acidic medium and determination of the unreacted oxidant by measuring the decrease in absorbance for five different dyes; methylene blue (MB); acid blue 74 (AB), acid red 73 (AR), amaranth dye (AM) and acid orange 7 (AO) at a suitable λmax (660, 610, 510, 520, and 485 nm), respectively. Regression analysis of Beer's plots showed good correlation in the concentration ranges (0.4 12.5, 0.3 10, 0.5 11, 0.4 8.3 and 0.5 9.3 μg ml-1), respectively. The apparent molar absorbtivity, Sandell sensitivity, detection and quantitation limits were calculated. For more accurate results, Ringbom optimum concentration ranges were 0.5 12, 0.5 9.6, 0.6 10.5, 0.5 8.0 and 0.7 9.0 μg ml-1, respectively. The validity of the proposed method was tested by analyzing in pure and dosage forms containing CAP whether alone or in combination with hydrochlorothiazide. Statistical analysis of the results reflects that the proposed procedures are precise, accurate and easily applicable for the determination of CAP in pure form and in pharmaceutical preparations. Also, the stability constant was determined and the free energy change was calculated potentiometrically.
Swimley, Michelle S.; Taylor, Amber W.; Dawson, Erica D.
2011-01-01
Abstract Shiga toxin–producing Escherichia coli O157 is a leading cause of foodborne illness worldwide. To evaluate better methods to rapidly detect and genotype E. coli O157 strains, the present study evaluated the use of ampliPHOX, a novel colorimetric detection method based on photopolymerization, for pathogen identification with DNA microarrays. A low-density DNA oligonucleotide microarray was designed to target stx1 and stx2 genes encoding Shiga toxin production, the eae gene coding for adherence membrane protein, and the per gene encoding the O157-antigen perosamine synthetase. Results from the validation experiments demonstrated that the use of ampliPHOX allowed the accurate genotyping of the tested E. coli strains, and positive hybridization signals were observed for only probes targeting virulence genes present in the reference strains. Quantification showed that the average signal-to-noise ratio values ranged from 47.73 ± 7.12 to 76.71 ± 8.33, whereas average signal-to-noise ratio values below 2.5 were determined for probes where no polymer was formed due to lack of specific hybridization. Sensitivity tests demonstrated that the sensitivity threshold for E. coli O157 detection was 100–1000 CFU/mL. Thus, the use of DNA microarrays in combination with photopolymerization allowed the rapid and accurate genotyping of E. coli O157 strains. PMID:21288130
Moonrungsee, Nuntaporn; Pencharee, Somkid; Jakmunee, Jaroon
2015-05-01
A field deployable colorimetric analyzer based on an "Android mobile phone" was developed for the determination of available phosphorus content in soil. An inexpensive mobile phone embedded with digital camera was used for taking photograph of the chemical solution under test. The method involved a reaction of the phosphorus (orthophosphate form), ammonium molybdate and potassium antimonyl tartrate to form phosphomolybdic acid which was reduced by ascorbic acid to produce the intense colored molybdenum blue. The software program was developed to use with the phone for recording and analyzing RGB color of the picture. A light tight box with LED light to control illumination was fabricated to improve precision and accuracy of the measurement. Under the optimum conditions, the calibration graph was created by measuring blue color intensity of a series of standard phosphorus solution (0.0-1.0mgPL(-1)), then, the calibration equation obtained was retained by the program for the analysis of sample solution. The results obtained from the proposed method agreed well with the spectrophotometric method, with a detection limit of 0.01mgPL(-1) and a sample throughput about 40h(-1) was achieved. The developed system provided good accuracy (RE<5%) and precision (RSD<2%, intra- and inter-day), fast and cheap analysis, and especially convenient to use in crop field for soil analysis of phosphorus nutrient. Copyright © 2015 Elsevier B.V. All rights reserved.
Nikzad, Nasrin; Karami, Zahra
2018-04-14
Changes in choline levels can be associated with diseases such as Alzheimer, Parkinson, Huntington, fatty liver, interstitial lung abnormalities, autism and so on. Therefore, quantitative determination of choline is important in the biological and clinical analysis. So far, several methods have been investigated for measuring choline in the body fluids, each of which has disadvantages such as the need for specialist ability, complexity, and high cost. For this purpose, a facile and sensitive colorimetric biosensor based on DNAzyme-choline oxidase coupling used for the determination of choline. In this method, the first, choline oxidase produces H 2 O 2 and betaine in the presence of choline and oxygen, then, the DNAzyme converts colorless ABTS into green ABTS + radicals. Compared to the previous methods, the linear range and the limit of detection of this talented biosensor were 0.1-25 μM and 22 nM. Choline measurement using this biosensor has shown satisfactory selectivity and repeatability. Its recovery was 96.9-103.7%, which shows the reliability of biosensor assay in biological samples. Simplicity, low cost, naked eye, high sensitivity, and precision are the benefits of this biosensor. Taken to gather, the proposed system can be considered as a great biosensor for measuring choline levels especially in point of care diagnostic. Copyright © 2018 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Pei, Peng-Xiang; Hu, Jing-Han; Long, Chen; Ni, Peng-Wei
2018-06-01
A novel chemosensor 2-((Z)-(((E)-quinolin-2-ylmethylene)hydrazono)methyl)phenol PX has been successfully designed and synthesized, which showed both colorimetric and "turn-on" fluorescence responses for CN- in DMSO/H2O (3:2, v/v; pH = 7.20) solution. The sensor could respond effectively to the stimulation of CN- ions via deprotonation and sensing mechanism of intramolecular charge transfer (ICT). Moreover, the sensor PX was successfully utilized to detect CN- in bitter almond, and the detection limit on fluorescence response of PX towards CN- was down to 4.5 × 10-7 M. Test strips containing PX were also prepared, which could act as a practical colorimetric tool to detect CN- in aqueous media.
NASA Astrophysics Data System (ADS)
Zhu, Qin; Li, Zhao; Mu, Lan; Zeng, Xi; Redshaw, Carl; Wei, Gang
2018-01-01
The compound (E)-8-hydroxyl-2-[(E)-2-(2, 4-dihydroxyphenyl)vinyl]-quinoline (1) has been developed as a fluorometric and colorimetric dual-modal probe for pH detection in solution and in vivo. Remarkable changes in the fluorescence intensity with large Stokes shifts and colorimetric responses were observed as a function of pH. The sensing mechanisms involving protonation and deprotonation processes over the acidic and alkaline pH ranges were confirmed by 1H NMR and IR spectroscopic analysis. Furthermore, the application of probe 1 for the imaging of live PC3 cells was successfully achieved. Test strips based on probe 1 were fabricated, and were found to act as a convenient and efficient pH test kits.
NASA Astrophysics Data System (ADS)
Wang, Yanfang; Yang, Na; Liu, Yi
2018-04-01
A novel organic small molecule with D-Pi-A structure was prepared, which was found to be a promising colorimetric and ratiometric UV-vis spetral probe for detection of phosphorylated proteins with the help of tetravalent zirconium ion. Such optical probe based on chromophore WYF-1 shows a rapid response (within 10 s) and high selectivity and sensitivity for phosphorylated proteins, giving distinct colorimetric and ratiometric UV-vis changes at 720 and 560 nm. The detection limit for phosphorylated proteins was estimated to be 100 nM. In addition, detection of phosphorylated proteins in placental tissue samples with this probe was successfully applied, which indicates that this probe holds great potential for phosphorylated proteins detection.
[Detection of viable metabolically active yeast cells using a colorimetric assay].
Růzicka, F; Holá, V
2008-02-01
The increasing concern of yeasts able to form biofilm brings about the need for susceptibility testing of both planktonic and biofilm cells. Detection of viability or metabolic activity of yeast cells after exposure to antimicrobials plays a key role in the assessment of susceptibility testing results. Colorimetric assays based on the color change of the medium in the presence of metabolically active cells proved suitable for this purpose. In this study, the usability of a colorimetric assay with the resazurin redox indicator for monitoring the effect of yeast inoculum density on the reduction rate was tested. As correlation between the color change rate and inoculum density was observed, approximate quantification of viable cells was possible. The assay would be of relevance to antifungal susceptibility testing in both planktonic and biofilm yeasts.
Design, Certification, and Deployment of the Colorimetric Water Quality Monitoring Kit (CWQMK)
NASA Technical Reports Server (NTRS)
Gazda, Daniel B.; Nolan, Daniel J.; Rutz, Jeff A.; Schultz, John R.; Siperko, Lorraine M.; Porter, Marc D.; Lipert, Robert J.; Flint, Stephanie M.; McCoy, J. Torin
2010-01-01
In August 2009, an experimental water quality monitoring kit based on Colorimetric Solid Phase Extraction (CSPE) technology was delivered to the International Space Station (ISS) aboard STS-128/17A. The kit, called the Colorimetric Water Quality Monitoring Kit (CWQMK), was flown and deployed as a Station Development Test Objective (SDTO) experiment on the ISS. The goal of the SDTO experiment is to evaluate the acceptability of CSPE technology for routine water quality monitoring on the ISS. This paper provides an overview of the SDTO experiment, as well as a detailed description of the CWQMK hardware and a summary of the testing and analysis conducted to certify the CWQMK for use on the ISS. The initial results obtained from the SDTO experiment are also reported and discussed in detail
NASA Astrophysics Data System (ADS)
Liu, Zhaodi; Xu, Huajie; Sheng, Liangquan; Chen, Shuisheng; Huang, Deqian; Liu, Jie
2016-03-01
A colorimetric and fluorescent chemosensor (L) for Al(III) was synthesized and fully characterized. L could be both used as a colorimetric and fluorescent chemosensor for the detection of Al3 + ions with low detection limit (8.87 × 10- 7 M) in CH3CN-H2O (1:1, v/v) solution. The binding ratio of L-Al3 + was determined from the Job plot (absorption and fluorescence spectra) and MALDI-TOF MS data to be 1:1. The binding constant (Ka) of Al3 + binding to L was calculated to be 4.8 × 105 M- 1 from a Benesi-Hildebrand plot. Moreover, the binding site of L with Al3 + was determined by 1H NMR titration experiment.
Vidya, Raj; Saji, Alex
2018-05-01
The development of an easy to use, one-pot, environmentally friendly, non-invasive and label-free colorimetric probe for the determination of semen protamines, the biochemical marker of male fertility, using heparin gold nanoparticles (HAuNPs) is presented. The affinity of HAuNPs for protamines was due to the electrostatic interactions between polycationic protamine and polyanionic heparin. The binding of HAuNPs to protamine was characterized by variation in the plasmon absorption spectra followed by a visibly observable colour change of the solution from red to blue. We observed a red shift in the plasmon peak and the method exhibited linearity in the range of 10-70 ng/mL with a detection limit of 5 ng/mL, which is much lower than that reported for colorimetric sensors of protamine. The colour change and the variation in the absorbance of HAuNPs were highly specific for protamines in the presence of different interfering compounds and the method was successfully applied for determining protamine in real samples of semen and serum. Rather than a quantitative estimation, it seems that the method provides a quick screening between a large array of positive and negative samples and, moreover, it maintains the privacy of the user. The method appears to be simple and would be very useful in third-world countries where high-tech diagnostic aids are inaccessible to the majority of the population. Graphical Abstract Heparin gold nanoparticles aided visual detection of infertility.
Colorimetric detection of melamine based on p-chlorobenzenesulfonic acid-modified AuNPs
NASA Astrophysics Data System (ADS)
Li, Jianfang; Huang, Pengcheng; Wu, Fangying
2016-06-01
A highly selective and sensitive method is developed for colorimetric detection of melamine using gold nanoparticles (AuNPs) functionalized with p-chlorobenzenesulfonic acid. The addition of melamine induced the aggregation of AuNPs, as evidenced from the morphological characterizations and the color changed from red wine to blue, which could also be monitored by the UV-visible spectrometer and even naked eyes. This process caused a significant increase in the absorbance ratio (A650nm/A520nm) of p-chlorobenzenesulfonic acid-AuNPs. Under optimized conditions, the system exhibited a linear response to melamine in the range of 6.0 × 10-7-1.5 × 10-6 mol L-1 with a correlation coefficient of 0.997, and the limit of detection can even be 2.3 nM, which was much lower than some other methods and the safe limits (20 μM in both the USA and EU, 8.0 μM for infant formula in China, 1.2 μM in the CAC (Codex Alimentarius Commission) review for melamine in liquid infant formula). More importantly, the developed method presented excellent tolerance to coexisting common metal ions such as Ca2+, Zn2+, whose concentration is 1000 times of melamine, so that it had been applied to the analysis of melamine in liquid milk and milk powder with the recovery of 97.0-101 % and 100-103 %, respectively, indicating that the proposed method is quite a highly effective means to determine melamine in milk products.