Controlling direct contact force for wet adhesion with different wedged film stabilities
NASA Astrophysics Data System (ADS)
Li, Meng; Xie, Jun; Shi, Liping; Huang, Wei; Wang, Xiaolei
2018-04-01
In solid–liquid–solid adhesive systems, wedged films often feature instability at microscopic thicknesses, which can easily disrupt the adhesive strength of their remarkable direct contact force. Here, sodium dodecyl sulfate (SDS) was employed to tune the instability of adhesion in wedged glass–water–rubber films, achieving controllable direct contact. Experimental results showed that the supplement of SDS molecules significantly weakened the direct contact force for wet adhesion and eliminated it at high concentrations. The underlying reason was suggested to be the repulsive double-layer force caused by SDS molecules, which lowers the instability of the wedged film and balances the preload, disrupting the direct contact in wet adhesion.
NASA Astrophysics Data System (ADS)
Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.
2018-06-01
Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.
NASA Astrophysics Data System (ADS)
Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.
2017-12-01
Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.
Refrigerant directly cooled capacitors
Hsu, John S [Oak Ridge, TN; Seiber, Larry E [Oak Ridge, TN; Marlino, Laura D [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN
2007-09-11
The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.
Passive Fetal Heart Monitoring System
NASA Technical Reports Server (NTRS)
Zuckerwar, Allan J. (Inventor); Mowrey, Dennis L. (Inventor)
2003-01-01
A fetal heart monitoring system and method for detecting and processing acoustic fetal heart signals transmitted by different signal transmission modes. One signal transmission mode, the direct contact mode, occurs in a first frequency band when the fetus is in direct contact with the maternal abdominal wall. Another signal transmission mode, the fluid propagation mode, occurs in a second frequency band when the fetus is in a recessed position with no direct contact with the maternal abdominal wall. The second frequency band is relatively higher than the first frequency band. The fetal heart monitoring system and method detect and process acoustic fetal heart signals that are in the first frequency band and in the second frequency band.
Immiscible fluid: Heat of fusion heat storage system
NASA Technical Reports Server (NTRS)
Edie, D. D.; Melsheimer, S. S.; Mullins, J. C.
1980-01-01
Both heat and mass transfer in direct contact aqueous crystallizing systems were studied as part of a program desig- ned to evaluate the feasibility of direct contact heat transfer in phase change storage using aqueous salt system. Major research areas, discussed include (1) crystal growth velocity study on selected salts; (2) selection of salt solutions; (3) selection of immiscible fluids; (4) studies of heat transfer and system geometry; and (5) system demonstration.
Rapier, P.M.
1980-06-26
A multi-stage flash degaser is incorporated in an energy conversion system having a direct-contact, binary-fluid heat exchanger to remove essentially all of the noncondensable gases from geothermal brine ahead of the direct-contact binary-fluid heat exchanger in order that the heat exchanger and a turbine and condenser of the system can operate at optimal efficiency.
Direct determination of three-phase contact line properties on nearly molecular scale
Winkler, P. M.; McGraw, R. L.; Bauer, P. S.; ...
2016-05-17
Wetting phenomena in multi-phase systems govern the shape of the contact line which separates the different phases. For liquids in contact with solid surfaces wetting is typically described in terms of contact angle. While in macroscopic systems the contact angle can be determined experimentally, on the molecular scale contact angles are hardly accessible. Here we report the first direct experimental determination of contact angles as well as contact line curvature on a scale of the order of 1nm. For water nucleating heterogeneously on Ag nanoparticles we find contact angles around 15 degrees compared to 90 degrees for the corresponding macroscopicallymore » measured equilibrium angle. The obtained microscopic contact angles can be attributed to negative line tension in the order of –10 –10 J/m that becomes increasingly dominant with increasing curvature of the contact line. Furthermore, these results enable a consistent theoretical description of heterogeneous nucleation and provide firm insight to the wetting of nanosized objects.« less
Rapier, Pascal M.
1982-01-01
A multi-stage flash degaser (18) is incorporated in an energy conversion system (10) having a direct-contact, binary-fluid heat exchanger to remove essentially all of the noncondensable gases from geothermal brine ahead of the direct-contact binary-fluid heat exchanger (22) in order that the heat exchanger (22) and a turbine (48) and condenser (32) of the system (10) can operate at optimal efficiency.
Air/molten salt direct-contact heat-transfer experiment and economic analysis
NASA Astrophysics Data System (ADS)
Bohn, M. S.
1983-11-01
Direct-contact heat-transfer coefficients have been measured in a pilot-scale packed column heat exchanger for molten salt/air duty. Two types of commercial tower packings were tested: metal Raschig rings and initial Pall rings. Volumetric heat-transfer coefficients were measured and appeared to depend upon air flow but not on salt flow rate. An economic analysis was used to compare the cost-effectiveness of direct-contact heat exchange with finned-tube heat exchanger in this application. Incorporating the measured volumetric heat-transfer coefficients, a direct-contact system appeared to be from two to five times as cost-effective as a finned-tube heat exchanger, depending upon operating temperature. The large cost advantage occurs for higher operating temperatures (2700(0)C), where high rates of heat transfer and flexibility in materials choice give the cost advantage to the direct-contact heat exchanger.
NASA Technical Reports Server (NTRS)
Weizer, V. G.; Fatemi, N. S.; Hoffman, R. W.
1995-01-01
Two contact systems for use on shallow junction InP solar cells are described. The feature shared by these two contact systems is the absence of the metallurgical intermixing that normally takes place between the semiconductor and the contact metallization during the sintering process. The n(+)pp(+) cell contact system, consisting of a combination of Au and Ge, not only exhibits very low resistance in the as-fabricated state, but also yields post-sinter resistivity values of 1(exp -7) ohms-sq cm, with effectively no metal-InP interdiffusion. The n(+)pp(+)cell contact system, consisting of a combination of Ag and Zn, permits low resistance ohmic contact to be made directly to a shallow junction p/n InP device without harming the device itself during the contacting process.
Plasmonic direct writing lithography with a macroscopical contact probe
NASA Astrophysics Data System (ADS)
Huang, Yuerong; Liu, Ling; Wang, Changtao; Chen, Weidong; Liu, Yunyue; Li, Ling
2018-05-01
In this work, we design a plasmonic direct writing lithography system with a macroscopical contact probe to achieve nanometer scale spots. The probe with bowtie-shaped aperture array adopts spring hinge and beam deflection method (BDM) to realize near-field lithography. Lithography results show that a macroscopical plasmonic contact probe can achieve a patterning resolution of around 75 nm at 365 nm wavelength, and demonstrate that the lithography system is promising for practical applications due to beyond the diffraction limit, low cost, and simplification of system configuration. CST calculations provide a guide for the design of recording structure and the arrangement of placing polarizer.
USDA-ARS?s Scientific Manuscript database
In order to optimize novel systems for African Swine Fever Virus (ASFV) vaccine development, domestic pigs were challenged with the highly virulent ASFV-Malawi strain via intraoropharyngeal (IOP), intranasopharyngeal (INP), intramuscular (IM), and direct contact (DC) routes. Direct challenge doses ...
Heat transfer characteristics of a surface type direct contact boiler
DOE Office of Scientific and Technical Information (OSTI.GOV)
Deeds, R.S.; Jacobs, H.R.; Boehm, R.F.
1976-03-01
Two direct contact heat exchangers were constructed and test results were obtained using water and refrigerant 113 as the working fluids. The heat exchangers were operated in a three-phase mode; the water remained liquid throughout the vessel and the liquid refrigerant 113 underwent vaporization following direct injection into the water. The effect of important operational parameters--operating heights, refrigerant 113 injection techniques, mass flow ratios, and temperatures--was studied to determine generalized trends important in the design and operation of a prototype three-phase direct contact heat exchanger. The primary system used in this study performed well overall. The initial favorable results ofmore » this study warrant further investigation of direct contact heat exchange as a means of utilizing geothermal energy.« less
75 FR 16662 - Airworthiness Directives; Kelly Aerospace Energy Systems, LLC Rebuilt Turbochargers
Federal Register 2010, 2011, 2012, 2013, 2014
2010-04-02
... Airworthiness Directives; Kelly Aerospace Energy Systems, LLC Rebuilt Turbochargers AGENCY: Federal Aviation... airworthiness directive (AD) for certain Kelly Aerospace Energy Systems, LLC (KAES) rebuilt turbochargers. This... Federal holidays. Fax: (202) 493-2251. Contact Kelly Aerospace Energy Systems, LLC, 2900 Selma Highway...
Renewable Water: Direct Contact Membrane Distillation Coupled With Solar Ponds
NASA Astrophysics Data System (ADS)
Suarez, F. I.; Tyler, S. W.; Childress, A. E.
2010-12-01
The exponential population growth and the accelerated increase in the standard of living have increased significantly the global consumption of two precious resources: water and energy. These resources are intrinsically linked and are required to allow a high quality of human life. With sufficient energy, water may be harvested from aquifers, treated for potable reuse, or desalinated from brackish and seawater supplies. Even though the costs of desalination have declined significantly, traditional desalination systems still require large quantities of energy, typically from fossil fuels that will not allow these systems to produce water in a sustainable way. Recent advances in direct contact membrane distillation can take advantage of low-quality or renewable heat to desalinate brackish water, seawater or wastewater. Direct contact membrane distillation operates at low pressures and can use small temperature differences between the feed and permeate water to achieve a significant freshwater production. Therefore, a much broader selection of energy sources can be considered to drive thermal desalination. A promising method for providing renewable source of heat for direct contact membrane distillation is a solar pond, which is an artificially stratified water body that captures solar radiation and stores it as thermal energy at the bottom of the pond. In this work, a direct contact membrane distillation/solar pond coupled system is modeled and tested using a laboratory-scale system. Freshwater production rates on the order of 2 L day-1 per m2 of solar pond (1 L hr-1 per m2 of membrane area) can easily be achieved with minimal operating costs and under low pressures. While these rates are modest, they are six times larger than those produced by other solar pond-powered desalination systems - and they are likely to be increased if heat losses in the laboratory-scale system are reduced. Even more, this system operates at much lower costs than traditional desalination systems, thus, it can be used to meet the future needs of energy and water use in a sustainable way.
Comparison of advanced thermal and electrical storage for parabolic dish solar thermal power systems
NASA Astrophysics Data System (ADS)
Fujita, T.; Birur, G. C.; Schredder, J. M.; Bowyer, J. M.; Awaya, H. I.
Parabolic dish solar concentrator cluster concepts are explored, with attention given to thermal storage systems coupled to Stirling and Brayton cycle power conversion devices. Sensible heat storage involving molten salt (NaOH), liquid sodium, and solid cordierite bricks are considered for 1500 F thermal storage systems. Latent heat storage with NaF-MgF2 phase change materials are explored in terms of passive, active, and direct contact designs. Comparisons are made of the effectiveness of thermal storage relative to redox, Na-S, Zn-Cl, and Zn-Br battery storage systems. Molten lead trickling down through a phase change eutectic, the NaF-MgF2, formed the direct contact system. Heat transport in all systems is effected through Inconel pipes. Using a cost goal of 120-150 mills/kWh as the controlling parameter, sensible heat systems with molten salts transport with either Stirling or Brayton engines, or latent heat systems with Stirling engines, and latent heat-Brayton engine with direct contact were favored in the analyses. Battery storage systems, however, offered the most flexibility of applications.
Comparison of advanced thermal and electrical storage for parabolic dish solar thermal power systems
NASA Technical Reports Server (NTRS)
Fujita, T.; Birur, G. C.; Schredder, J. M.; Bowyer, J. M.; Awaya, H. I.
1982-01-01
Parabolic dish solar concentrator cluster concepts are explored, with attention given to thermal storage systems coupled to Stirling and Brayton cycle power conversion devices. Sensible heat storage involving molten salt (NaOH), liquid sodium, and solid cordierite bricks are considered for 1500 F thermal storage systems. Latent heat storage with NaF-MgF2 phase change materials are explored in terms of passive, active, and direct contact designs. Comparisons are made of the effectiveness of thermal storage relative to redox, Na-S, Zn-Cl, and Zn-Br battery storage systems. Molten lead trickling down through a phase change eutectic, the NaF-MgF2, formed the direct contact system. Heat transport in all systems is effected through Inconel pipes. Using a cost goal of 120-150 mills/kWh as the controlling parameter, sensible heat systems with molten salts transport with either Stirling or Brayton engines, or latent heat systems with Stirling engines, and latent heat-Brayton engine with direct contact were favored in the analyses. Battery storage systems, however, offered the most flexibility of applications.
Kusdemir, Mahmut; Gunal, Solen; Ozer, Fusun; Imazato, Satoshi; Izutani, Naomi; Ebisu, Shigeyuki; Blatz, Markus B
2011-01-01
This study evaluated the cytotoxicity of self-etching primers/adhesives by direct contact and dentin barrier tests. The three two-step self-etching systems Clearfil SE Bond (CSE), Clearfil Protect Bond (CPB), Prime&Bond NT/NRC (PB) and one-step self-etching systems Reactmer Bond (RB), Clearfil Tri-S Bond (CTS), and Adper Prompt L-Pop (AP) were examined. In direct contact tests, L929 cells were cultured in the presence of diluted solutions (50, 20, 10, and 1%) of primer/conditioner of adhesive systems. For dentin barrier tests, each system was applied onto 0.5 or 1.5 mm thick human dentin assembled in a simple pulp chamber device and incubated for 24 h at 37°C to make the diffusive components contact the L929 cells placed at the bottom of the chamber. The cytotoxic effects were assessed by MTT assay. Cell culture without application of any primers/adhesives served as the control for both tests. One-way ANOVA and Tukey HSD tests were used for statistical analyses. The direct contact tests demonstrated that CSE and CPB were less toxic than the other materials at all dilutions. In the dentin barrier tests, toxic effects of materials were reduced with an increase in thickness of intervening dentin. CSE and CPB showed less cytotoxicity than the other adhesives (p<0.05) when applied to 0.5 mm-thick dentin, and CSE was the least toxic in the 1.5 mm-dentin group (p<0.05). Dentin thickness positively affected biocompatibility of the tested bonding systems. Two-step self-etching systems with HEMA-based primers were more biocompatible than other self-etching adhesives.
Pimenova, Anastasiya V; Goldobin, Denis S
2014-11-01
We consider the problem of boiling of the direct contact of two immiscible liquids. An intense vapour formation at such a direct contact is possible below the bulk boiling points of both components, meaning an effective decrease of the boiling temperature of the system. Although the phenomenon is known in science and widely employed in technology, the direct contact boiling process was thoroughly studied (both experimentally and theoretically) only for the case where one of liquids is becoming heated above its bulk boiling point. On the contrary, we address the case where both liquids remain below their bulk boiling points. In this paper we construct the theoretical description of the boiling process and discuss the actualisation of the case we consider for real systems.
Direct measurement of friction of a fluctuating contact line
NASA Astrophysics Data System (ADS)
Guo, Shuo; Gao, Min; Xiong, Xiaomin; Wang, Yong Jian; Wang, Xiaoping; Sheng, Ping; Tong, Penger
2013-03-01
What happens at a moving contact line, where one fluid displaces another (immiscible) fluid over a solid surface, is a fundamental issue in fluid dynamics. In this presentation, we report a direct measurement of the friction coefficient in the immediate vicinity of a fluctuating contact line using a micron-sized vertical glass fiber with one end glued to an atomic force microscope (AFM) cantilever beam and the other end touching a liquid-air interface. By measuring the broadening of the resonance peak of the cantilever system with varying liquid viscosity η, we obtain the friction coefficient ξc associated with the contact line fluctuations on the glass fiber of diameter d and find it has the universal form, ξc = 0 . 8 πdη , independent of the contact angle. The result is further confirmed by using a soap film system whose bulk effect is negligibly small. This is the first time that the friction coefficient of a fluctuating contact line is measured. *Work supported by the Research Grants Council of Hong Kong SAR.
NASA Astrophysics Data System (ADS)
Brothers, P.; Karaki, S.
Using a solar computer simulation package called TRNSYS, simulations of the direct contact liquid-liquid heat exchanger (DCLLHE) solar system and a system with conventional shell-and-tube heat exchanger were developed, based in part on performance measurements of the actual systems. The two systems were simulated over a full year on an hour-by-hour basis at five locations; Boston, Massachusetts, Charleston, South Carolina, Dodge City, Kansas, Madison, Wisconsin, and Phoenix, Arizona. Typically the direct-contact system supplies slightly more heat for domestic hot water and space heating in all locations and about 5 percentage points more cooling as compared to the conventional system. Using a common set of economic parameters and the appropriate federal and state income tax credits, as well as property tax legislation for solar systems in the corresponding states, the results of the study indicate for heating-only systems, the DCLLHE system has a slight life-cycle cost disadvantage compared to the conventional system. For combined solar heating and cooling systems, the DCLLHE has a slight life-cycle cost advantage which varies with location and amounts to one to three percent difference from the conventional system.
Steuwe, Carolin; Daniels, Judith K; Frewen, Paul A; Densmore, Maria; Pannasch, Sebastian; Beblo, Thomas; Reiss, Jeffrey; Lanius, Ruth A
2014-01-01
In healthy individuals, direct eye contact initially leads to activation of a fast subcortical pathway, which then modulates a cortical route eliciting social cognitive processes. The aim of this study was to gain insight into the neurobiological effects of direct eye-to-eye contact using a virtual reality paradigm in individuals with posttraumatic stress disorder (PTSD) related to prolonged childhood abuse. We examined 16 healthy comparison subjects and 16 patients with a primary diagnosis of PTSD using a virtual reality functional magnetic resonance imaging paradigm involving direct vs averted gaze (happy, sad, neutral) as developed by Schrammel et al. in 2009. Irrespective of the displayed emotion, controls exhibited an increased blood oxygenation level-dependent response during direct vs averted gaze within the dorsomedial prefrontal cortex, left temporoparietal junction and right temporal pole. Under the same conditions, individuals with PTSD showed increased activation within the superior colliculus (SC)/periaqueductal gray (PAG) and locus coeruleus. Our findings suggest that healthy controls react to the exposure of direct gaze with an activation of a cortical route that enhances evaluative 'top-down' processes underlying social interactions. In individuals with PTSD, however, direct gaze leads to sustained activation of a subcortical route of eye-contact processing, an innate alarm system involving the SC and the underlying circuits of the PAG.
Steuwe, Carolin; Daniels, Judith K.; Frewen, Paul A.; Densmore, Maria; Pannasch, Sebastian; Beblo, Thomas; Reiss, Jeffrey; Lanius, Ruth A.
2014-01-01
In healthy individuals, direct eye contact initially leads to activation of a fast subcortical pathway, which then modulates a cortical route eliciting social cognitive processes. The aim of this study was to gain insight into the neurobiological effects of direct eye-to-eye contact using a virtual reality paradigm in individuals with posttraumatic stress disorder (PTSD) related to prolonged childhood abuse. We examined 16 healthy comparison subjects and 16 patients with a primary diagnosis of PTSD using a virtual reality functional magnetic resonance imaging paradigm involving direct vs averted gaze (happy, sad, neutral) as developed by Schrammel et al. in 2009. Irrespective of the displayed emotion, controls exhibited an increased blood oxygenation level-dependent response during direct vs averted gaze within the dorsomedial prefrontal cortex, left temporoparietal junction and right temporal pole. Under the same conditions, individuals with PTSD showed increased activation within the superior colliculus (SC)/periaqueductal gray (PAG) and locus coeruleus. Our findings suggest that healthy controls react to the exposure of direct gaze with an activation of a cortical route that enhances evaluative ‘top–down’ processes underlying social interactions. In individuals with PTSD, however, direct gaze leads to sustained activation of a subcortical route of eye-contact processing, an innate alarm system involving the SC and the underlying circuits of the PAG. PMID:22977200
Liquid-Feed Methanol Fuel Cell With Membrane Electrolyte
NASA Technical Reports Server (NTRS)
Surampudi, Subbarao; Narayanan, S. R.; Halpert, Gerald; Frank, Harvey; Vamos, Eugene
1995-01-01
Fuel cell generates electricity from direct liquid feed stream of methanol/water solution circulated in contact with anode, plus direct gaseous feed stream of air or oxygen in contact with cathode. Advantages include relative simplicity and elimination of corrosive electrolytic solutions. Offers potential for reductions in size, weight, and complexity, and for increases in safety of fuel-cell systems.
77 FR 58761 - Airworthiness Directives; Empresa Brasileira de Aeronautica S.A. (EMBRAER) Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-24
... lightning strikes from causing certain parts to contact the airplane pitch control system, which could... lightning strike effects [could cause certain parts to contact the airplane pitch control system, which... a lightning strike hitting an airplane tail boom causing certain rear bulkhead parts to jam an...
Tosa, Marie I; Schauber, Eric M; Nielsen, Clayton K
2015-01-01
Social interactions can influence infectious disease dynamics, particularly for directly transmitted pathogens. Therefore, reliable information on contact frequency within and among groups can better inform disease modeling and management. We compared three methods of assessing contact patterns: (1) space-use overlap (volume of interaction [VI]), (2) direct contact rates measured by simultaneous global positioning system (GPS) locations (<10 m apart), and (3) direct contact rates measured by proximity loggers (PLs; 1-m detection) among female white-tailed deer (Odocoileus virginianus). We calculated the PL∶GPS contact ratios to see whether both devices reveal similar contact patterns and thus predict similar pathogen transmission patterns. Contact rates measured by GPS and PLs were similarly high for two within-group dyads (pairs of deer in the same social groups). Dyads representing separate but neighboring groups (high VI) had PL∶GPS contact ratios near zero, whereas dyads further apart (intermediate VI) had higher PL∶GPS contact ratios. Social networks based on PL contacts showed the fewest connected individuals and lowest mean centrality measures; network metrics were intermediate when based on GPS contacts and greatest when based on VI. Thus, the VI network portrayed animals to be more uniformly and strongly connected than did the PL network. We conclude that simultaneous GPS locations, compared with PLs, substantially underestimate the impact of group membership on direct contact rates of female deer and make networks appear more connected. We also present evidence that deer coming within the general vicinity of each other are less likely to come in close contact if they are in neighboring social groups than deer whose home ranges overlap little if at all. Combined, these results provide evidence that direct transmission of disease agents among female and juvenile white-tailed deer is likely to be constrained both spatially and by social structure, more so than GPS data alone would suggest.
Contact angle control of sessile drops on a tensioned web
NASA Astrophysics Data System (ADS)
Park, Janghoon; Kim, Dongguk; Lee, Changwoo
2018-04-01
In this study, the influence of the change of tension applied to flexible and thin web substrate on the contact angle of sessile drop in roll-to-roll system was investigated. Graphene oxide and deionized water solutions were used in the experiments. Tension was changed to 29, 49, and 69 N, and the casting distance of the micropipette and the material was set to 10, 20, and 40 mm, and the droplet volume was set to 10, 20, and 30 μL, respectively. Statistical analysis of three variables and analysis of the variance methodology showed that the casting distance was most significant for the contact angle change, and the most interesting tension variable was also affected. The change in tension caused the maximum contact angle to change by 5.5°. The tension was not uniform in the width direction. When the droplet was applied in the same direction in the width direction, it was confirmed that the tension unevenness had great influence on the contact angle up to 11°. Finally, the casting distance, which has a large effect on the contact angle, was calibrated in the width direction to reduce the width direction contact angle deviation to 1%. This study can be applied to fine patterning research using continuous inkjet printing and aerosol jet printing, which are roll-to-roll processes based on droplet handling.
Salazar-Badillo, Fatima Berenice; Sánchez-Rangel, Diana; Becerra-Flora, Alicia; López-Gómez, Miguel; Nieto-Jacobo, Fernanda; Mendoza-Mendoza, Artemio; Jiménez-Bremont, Juan Francisco
2015-10-01
Plants are associated with a wide range of microorganisms throughout their life cycle, and some interactions result on plant benefits. Trichoderma species are plant beneficial fungi that enhance plant growth and development, contribute to plant nutrition and induce defense responses. Nevertheless, the molecules involved in these beneficial effects still need to be identify. Polyamines are ubiquitous molecules implicated in plant growth and development, and in the establishment of plant microbe interactions. In this study, we assessed the polyamine profile in Arabidopsis plants during the interaction with Trichoderma virens and Trichoderma atroviride, using a system that allows direct plant-fungal contact or avoids their physical interaction (split system). The plantlets that grew in the split system exhibited higher biomass than the ones in direct contact with Trichoderma species. After 3 days of interaction, a significant decrease in Arabidopsis polyamine levels was observed in both systems (direct contact and split). After 5 days of interaction polyamine levels were increased. The highest levels were observed with T. atroviride (split system), and with T. virens (direct contact). The expression levels of Arabidopsis ADC1 and ADC2 genes during the interaction with the fungi were also assessed. We observed a time dependent regulation of ADC1 and ADC2 genes, which correlates with polyamine levels. Our data show an evident change in polyamine profile during Arabidopsis - Trichoderma interaction, accompanied by evident alterations in plant root architecture. Polyamines could be involved in the changes undergone by plant during the interaction with this beneficial fungus. Copyright © 2015 Elsevier Masson SAS. All rights reserved.
Berry, G.F.; Minkov, V.; Petrick, M.
1981-11-02
A magnetohydrodynamic (MHD) power generating system is described in which ionized combustion gases with slag and seed are discharged from an MHD combustor and pressurized high temperature inlet air is introduced into the combustor for supporting fuel combustion at high temperatures necessary to ionize the combustion gases, and including a heat exchanger in the form of a continuous loop with a circulating heat transfer liquid such as copper oxide. The heat exchanger has an upper horizontal channel for providing direct contact between the heat transfer liquid and the combustion gases to cool the gases and condense the slag which thereupon floats on the heat transfer liquid and can be removed from the channel, and a lower horizontal channel for providing direct contact between the heat transfer liquid and pressurized air for preheating the inlet air. The system further includes a seed separator downstream of the heat exchanger.
Berry, Gregory F.; Minkov, Vladimir; Petrick, Michael
1988-01-05
A magnetohydrodynamic (MHD) power generating system in which ionized combustion gases with slag and seed are discharged from an MHD combustor and pressurized high temperature inlet air is introduced into the combustor for supporting fuel combustion at high temperatures necessary to ionize the combustion gases, and including a heat exchanger in the form of a continuous loop with a circulating heat transfer liquid such as copper oxide. The heat exchanger has an upper horizontal channel for providing direct contact between the heat transfer liquid and the combustion gases to cool the gases and condense the slag which thereupon floats on the heat transfer liquid and can be removed from the channel, and a lower horizontal channel for providing direct contact between the heat transfer liquid and pressurized air for preheating the inlet air. The system further includes a seed separator downstream of the heat exchanger.
Berry, Gregory F.; Minkov, Vladimir; Petrick, Michael
1988-01-01
A magnetohydrodynamic (MHD) power generating system in which ionized combustion gases with slag and seed are discharged from an MHD combustor and pressurized high temperature inlet air is introduced into the combustor for supporting fuel combustion at high temperatures necessary to ionize the combustion gases, and including a heat exchanger in the form of a continuous loop with a circulating heat transfer liquid such as copper oxide. The heat exchanger has an upper horizontal channel for providing direct contact between the heat transfer liquid and the combustion gases to cool the gases and condense the slag which thereupon floats on the heat transfer liquid and can be removed from the channel, and a lower horizontal channel for providing direct contact between the heat transfer liquid and pressurized air for preheating the inlet air. The system further includes a seed separator downstream of the heat exchanger.
Satellite antenna management system and method
NASA Technical Reports Server (NTRS)
Leath, Timothy T (Inventor); Azzolini, John D (Inventor)
1999-01-01
The antenna management system and method allow a satellite to communicate with a ground station either directly or by an intermediary of a second satellite, thus permitting communication even when the satellite is not within range of the ground station. The system and method employ five major software components, which are the control and initialization module, the command and telemetry handler module, the contact schedule processor module, the contact state machining module, and the telemetry state machine module. The control and initialization module initializes the system and operates the main control cycle, in which the other modules are called. The command and telemetry handler module handles communication to and from the ground station. The contact scheduler processor module handles the contact entry schedules to allow scheduling of contacts with the second satellite. The contact and telemetry state machine modules handle the various states of the satellite in beginning, maintaining and ending contact with the second satellite and in beginning, maintaining and ending communication with the satellite.
Clark, Ryan R; Judd, Julius; Lasek-Nesselquist, Erica; Montgomery, Sarah A; Hoffmann, Jennifer G; Derbyshire, Keith M; Gray, Todd A
2018-06-25
Conjugal cell-cell contact between strains of Mycobacterium smegmatis induces the esxUT transcript, which encodes the putative primary substrates of the ESAT-6 secretion system 4 (ESX-4) secretion system. This recipient response was required for conjugal transfer of chromosomal DNA from the donor strain. Here we show that the extracytoplasmic σ factor, SigM, is a cell contact-dependent activator of ESX-4 expression and is required for conjugal transfer of DNA in the recipient strain. The SigM regulon includes genes outside the seven-gene core esx4 locus that we show are also required for conjugation, and we show that some of these SigM-induced proteins likely function through ESX-4. A fluorescent reporter revealed that SigM is specifically activated in recipient cells in direct contact with donor cells. Coculture RNA-seq experiments indicated that SigM regulon induction occurred early and before transconjugants are detected. This work supports a model wherein donor contact with the recipient cell surface inactivates the transmembrane anti-SigM, thereby releasing SigM. Free SigM induces an extended ESX-4 secretion system, resulting in changes that facilitate chromosomal transfer. The contact-dependent inactivation of an extracytoplasmic σ-factor that tightly controls ESX-4 activity suggests a mechanism dedicated to detect, and appropriately respond to, external stimuli from mycobacteria.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Abdulla, S.; Liu, X.; Anderson, M.H.
One concept being considered for steam generation in innovative nuclear reactor applications, involves water coming into direct contact with a circulating molten metal. The vigorous agitation of the two fluids, the direct liquid-liquid contact and the consequent large interfacial area can give rise to large heat transfer coefficients and rapid steam generation. For an optimum design of such direct contact heat exchange and vaporization systems, detailed knowledge is necessary of the various flow regimes, interfacial transport phenomena, heat transfer and operational stability. In order to investigate the interfacial transport phenomena, heat transfer and operational stability of direct liquid-liquid contact, amore » series of experiments are being performed in a 1-d test facility at Argonne National Laboratory and a 2-d experimental facility at UW-Madison. Each of the experimental facilities primarily consist of a liquid-metal melt chamber, heated test section (10 cm diameter tube for 1-d facility and 10 cm 50 cm rectangle for 2-d facility), water injection system and steam suppression tank. This paper is part II which, primarily addresses results and analysis of a set of preliminary experiments and void fraction measurements conducted in the 2-d facility at UW-Madison, part I deals with the heat transfer in the 1-d test facility at Argonne National Laboratory. A real-time high energy X-ray imaging system was developed and utilized to visualize the multiphase flow and measure line-average local void fractions, time-dependent void fraction distribution as well as estimates of the vapor bubble sizes and velocities. These measurements allowed us to determine the volumetric heat transfer coefficient and gain insight into the local heat transfer mechanisms. In this study, the images were captured at frame rates of 100 fps with spatial resolution of about 7 mm with a full-field view of a 15 cm square and five different positions along the test section height. The full-field average void fraction increases rapidly to about 15% in these preliminary tests, with the apparent boiling length of less than 20 cm. The volumetric heat transfer coefficient between the liquid metal and water are compared to the CRIEPI data, the only prior data for direct contact heat exchange for these liquid metal/water systems. (authors)« less
Non-contact finger vein acquisition system using NIR laser
NASA Astrophysics Data System (ADS)
Kim, Jiman; Kong, Hyoun-Joong; Park, Sangyun; Noh, SeungWoo; Lee, Seung-Rae; Kim, Taejeong; Kim, Hee Chan
2009-02-01
Authentication using finger vein pattern has substantial advantage than other biometrics. Because human vein patterns are hidden inside the skin and tissue, it is hard to forge vein structure. But conventional system using NIR LED array has two drawbacks. First, direct contact with LED array raise sanitary problem. Second, because of discreteness of LEDs, non-uniform illumination exists. We propose non-contact finger vein acquisition system using NIR laser and Laser line generator lens. Laser line generator lens makes evenly distributed line laser from focused laser light. Line laser is aimed on the finger longitudinally. NIR camera was used for image acquisition. 200 index finger vein images from 20 candidates are collected. Same finger vein pattern extraction algorithm was used to evaluate two sets of images. Acquired images from proposed non-contact system do not show any non-uniform illumination in contrary with conventional system. Also results of matching are comparable to conventional system. We developed Non-contact finger vein acquisition system. It can prevent potential cross contamination of skin diseases. Also the system can produce uniformly illuminated images unlike conventional system. With the benefit of non-contact, proposed system shows almost equivalent performance compared with conventional system.
Working Group on Ice Forces on Structures. A State-of-the-Art Report.
1980-06-01
observed in Soviet Design Codes, but the randomness of ice properties is not directly observed anywhere. 3.3 Contact system The mode of ice failure against...ups .............. o..........................90 2.133 Factors limiting ice ride-up ..................... o............91 2.134 Procedures for designing ...o................................110 3.3 Contact system .................................................. 115 3.4 Damping
Design, Development, Testing, and Evaluation: Human Factors Engineering
NASA Technical Reports Server (NTRS)
Adelstein, Bernard; Hobbs, Alan; OHara, John; Null, Cynthia
2006-01-01
While human-system interaction occurs in all phases of system development and operation, this chapter on Human Factors in the DDT&E for Reliable Spacecraft Systems is restricted to the elements that involve "direct contact" with spacecraft systems. Such interactions will encompass all phases of human activity during the design, fabrication, testing, operation, and maintenance phases of the spacecraft lifespan. This section will therefore consider practices that would accommodate and promote effective, safe, reliable, and robust human interaction with spacecraft systems. By restricting this chapter to what the team terms "direct contact" with the spacecraft, "remote" factors not directly involved in the development and operation of the vehicle, such as management and organizational issues, have been purposely excluded. However, the design of vehicle elements that enable and promote ground control activities such as monitoring, feedback, correction and reversal (override) of on-board human and automation process are considered as per NPR8705.2A, Section 3.3.
Biomechanical analysis of a new lumbar interspinous device with optimized topology.
Chen, Chen-Sheng; Shih, Shih-Liang
2018-01-06
Interspinous spacers used stand-alone preserve joint movement but provide little protection for diseased segments of the spine. Used as adjuncts with fusion, interspinous spacers offer rigid stability but may accelerate degeneration on adjacent levels. Our new device is intended to balance the stability and preserves motion provided by the implant. A new interspinous spacer was devised according to the results of topology optimization studies. Four finite element (FE) spine models were created that consisted of an intact spine without an implant, implantation of the novel, the device for intervertebral assisted motion (DIAM system), and the Dynesys system. All models were loaded with moments, and their range of motions (ROMs), peak disc stresses, and facet contact forces were analyzed. The limited motion segment ROMs, shielded disc stresses, and unloaded facet contact forces of the new devices were greater than those of the DIAM and Dynesys system at L3-L4 in almost all directions of movements. The ROMs, disc stresses, and facet contact forces of the new devices at L2-L3 were slightly greater than those in the DIAM system, but much lower than those in the Dynesys system in most directions. This study demonstrated that the new device provided more stability at the instrumented level than the DIAM system did, especially in lateral rotation and the bending direction. The device caused fewer adjacent ROMs, lower disc stresses, and lower facet contact forces than the Dynesys system did. Additionally, this study conducted topology optimization to design the new device and created a smaller implant for minimal invasive surgery.
CYTOTOXICITY AND BIOCOMPATIBILITY OF DIRECT AND INDIRECT PULP CAPPING MATERIALS
Modena, Karin Cristina da Silva; Casas-Apayco, Leslie Caroll; Atta, Maria Teresa; Costa, Carlos Alberto de Souza; Hebling, Josimeri; Sipert, Carla Renata; Navarro, Maria Fidela de Lima; Santos, Carlos Ferreira
2009-01-01
There are several studies about the cytotoxic effects of dental materials in contact with the pulp tissue, such as calcium hydroxide (CH), adhesive systems, resin composite and glass ionomer cements. The aim of this review article was to summarize and discuss the cytotoxicity and biocompatibility of materials used for protection of the dentin-pulp complex, some components of resin composites and adhesive systems when placed in direct or indirect contact with the pulp tissue. A large number of dental materials present cytotoxic effects when applied close or directly to the pulp, and the only material that seems to stimulate early pulp repair and dentin hard tissue barrier formation is CH. PMID:20027424
Non-Dissipative Structural Evolutions in Granular Materials
NASA Astrophysics Data System (ADS)
Pouragha, Mehdi; Wan, Richard
2017-06-01
The structure of the contact network in granular assemblies can evolve due to either dissipative mechanisms such as sliding at contact points, or non-dissipative mechanisms through the phenomenon of contact gain and loss. Being associated with negligible deformations, non-dissipative mechanisms is actually active even in the small strain range of 10-3, especially in the case of densely packed assemblies. Hence, from a constitutive modelling point of view, it is crucial to be able to estimate such non-dissipative evolutions since both elastic and plastic properties of granular assemblies highly depend on contact network characteristics. The current study proposes an analytical scheme that allows us to estimate the non-dissipative contact gain/loss regime in terms of directional changes in the average contact force. The probability distribution of contact forces is used to compute the number of lost contact for each direction. Similarly, the number of newly formed contacts is estimated by considering the probability distribution of the gap between neighbouring particles. Based on the directional contact gain/loss computed, the changes in coordination number and fabric anisotropy can be found which, together with statistical treatments of Love-Weber stress expression, form a complete system of equations describing the evolution of other controlling microvariables. Finally, the results of the calculations have been compared with DEM simulations which verify the accuracy of the proposed scheme.
NASA Astrophysics Data System (ADS)
Zhong, Chuyu; Zhang, Xing; Hofmann, Werner; Yu, Lijuan; Liu, Jianguo; Ning, Yongqiang; Wang, Lijun
2018-05-01
Few-mode vertical-cavity surface-emitting lasers that can be controlled to emit certain modes and polarization states simply by changing the biased contacts are proposed and fabricated. By directly etching trenches in the p-doped distributed Bragg reflector, the upper mesa is separated into several submesas above the oxide layer. Individual contacts are then deposited. Each contact is used to control certain transverse modes with different polarization directions emitted from the corresponding submesa. These new devices can be seen as a prototype of compact laser sources in mode division multiplexing communications systems.
van Golde, Celine; Verstraten, Frans A. J.
2017-01-01
The speed and ease with which we recognize the faces of our friends and family members belies the difficulty we have recognizing less familiar individuals. Nonetheless, overconfidence in our ability to recognize faces has carried over into various aspects of our legal system; for instance, eyewitness identification serves a critical role in criminal proceedings. For this reason, understanding the perceptual and psychological processes that underlie false identification is of the utmost importance. Gaze direction is a salient social signal and direct eye contact, in particular, is thought to capture attention. Here, we tested the hypothesis that differences in gaze direction may influence difficult decisions in a lineup context. In a series of experiments, we show that when a group of faces differed in their gaze direction, the faces that were making eye contact with the participants were more likely to be misidentified. Interestingly, this bias disappeared when the faces are presented with their eyes closed. These findings open a critical conversation between social neuroscience and forensic psychology, and imply that direct eye contact may (wrongly) increase the perceived familiarity of a face. PMID:28203355
NASA Astrophysics Data System (ADS)
Rhee, Hyop S.; Begg, Lester L.; Wetch, Joseph R.; Jang, Jong H.; Juhasz, Albert J.
An innovative pumped loop concept for 600 K space power system radiators utilizing direct contact heat transfer, which facilitates repeated startup/shutdown of the power system without complex and time-consuming coolant thawing during power startup, is under development. The heat transfer process with melting/freezing of Li in an NaK flow was studied through two-dimensional time-dependent numerical simulations to characterize and predict the Li/NaK radiator performance during startup (thawing) and shutdown (cold-trapping). Effects of system parameters and the criteria for the plugging domain are presented together with temperature distribution patterns in solid Li and subsequent melting surface profile variations in time.
78 FR 60673 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-02
...-140, 1200 New Jersey Avenue SE., Washington, DC 20590. FOR FURTHER INFORMATION CONTACT: Ray Mei...) Related Information For more information about this AD, contact Ray Mei, Aerospace Engineer, Systems and...://www.myboeingfleet.com . (4) You may view this service information at FAA, Transport Airplane...
Dynamics of fingertip contact during the onset of tangential slip
Delhaye, Benoit; Lefèvre, Philippe; Thonnard, Jean-Louis
2014-01-01
Through highly precise perceptual and sensorimotor activities, the human tactile system continuously acquires information about the environment. Mechanical interactions between the skin at the point of contact and a touched surface serve as the source of this tactile information. Using a dedicated custom robotic platform, we imaged skin deformation at the contact area between the finger and a flat surface during the onset of tangential sliding movements in four different directions (proximal, distal, radial and ulnar) and with varying normal force and tangential speeds. This simple tactile event evidenced complex mechanics. We observed a reduction of the contact area while increasing the tangential force and proposed to explain this phenomenon by nonlinear stiffening of the skin. The deformation's shape and amplitude were highly dependent on stimulation direction. We conclude that the complex, but highly patterned and reproducible, deformations measured in this study are a potential source of information for the central nervous system and that further mechanical measurement are needed to better understand tactile perceptual and motor performances. PMID:25253033
Wang, Hongsheng; Chen, Tony; Koff, Matthew F.; Hutchinson, Ian D.; Gilbert, Susannah; Choi, Dan; Warren, Russell F.; Rodeo, Scott A.; Maher, Suzanne A.
2014-01-01
To understand the mechanical consequences of knee injury requires a detailed analysis of the effect of that injury on joint contact mechanics during activities of daily living. Three-dimensional (3D) knee joint geometric models have been combined with knee joint kinematics to dynamically estimate the location of joint contact during physiological activities – using a weighted center of proximity (WCoP) method. However, the relationship between the estimated WCoP and the actual location of contact has not been defined. The objective of this study was to assess the relationship between knee joint contact location as estimated using the image-based WCoP method, and a directly measured weighted center of contact (WCoC) method during simulated walking. To achieve this goal, we created knee specific models of six human cadaveric knees from magnetic resonance imaging. All knees were then subjected to physiological loads on a knee simulator intended to mimic gait. Knee joint motion was captured using a motion capture system. Knee joint contact stresses were synchronously recorded using a thin electronic sensor throughout gait, and used to compute WCoC for the medial and lateral plateaus of each knee. WCoP was calculated by combining knee kinematics with the MRI-based knee specific model. Both metrics were compared throughout gait using linear regression. The anteroposterior (AP) location of WCoP was significantly correlated with that of WCoC on both tibial plateaus in all specimens (P < 0.01, 95% confidence interval of Person’s coefficient r > 0), but the correlation was not significant in the mediolateral (ML) direction for 4/6 knees (P > 0.05). Our study demonstrates that while the location of joint contact obtained from 3D knee joint contact model, using the WCoP method, is significantly correlated with the location of actual contact stresses in the AP direction, that relationship is less certain in the ML direction. PMID:24837219
Badgers prefer cattle pasture but avoid cattle: implications for bovine tuberculosis control.
Woodroffe, Rosie; Donnelly, Christl A; Ham, Cally; Jackson, Seth Y B; Moyes, Kelly; Chapman, Kayna; Stratton, Naomi G; Cartwright, Samantha J
2016-10-01
Effective management of infectious disease relies upon understanding mechanisms of pathogen transmission. In particular, while models of disease dynamics usually assume transmission through direct contact, transmission through environmental contamination can cause different dynamics. We used Global Positioning System (GPS) collars and proximity-sensing contact-collars to explore opportunities for transmission of Mycobacterium bovis [causal agent of bovine tuberculosis] between cattle and badgers (Meles meles). Cattle pasture was badgers' most preferred habitat. Nevertheless, although collared cattle spent 2914 collar-nights in the home ranges of contact-collared badgers, and 5380 collar-nights in the home ranges of GPS-collared badgers, we detected no direct contacts between the two species. Simultaneous GPS-tracking revealed that badgers preferred land > 50 m from cattle. Very infrequent direct contact indicates that badger-to-cattle and cattle-to-badger M. bovis transmission may typically occur through contamination of the two species' shared environment. This information should help to inform tuberculosis control by guiding both modelling and farm management. © 2016 John Wiley & Sons Ltd/CNRS.
Integrated microelectromechanical gyroscope under shock loads
NASA Astrophysics Data System (ADS)
Nesterenko, T. G.; Koleda, A. N.; Barbin, E. S.
2018-01-01
The paper presents a new design of a shock-proof two-axis microelectromechanical gyroscope. Without stoppers, the shock load enables the interaction between the silicon sensor elements. Stoppers were installed in the gyroscope to prevent the contact interaction between electrodes and spring elements with fixed part of the sensor. The contact of stoppers occurs along the plane, thereby preventing the system from serious contact stresses. The shock resistance of the gyroscope is improved by the increase in its eigenfrequency at which the contact interaction does not occur. It is shown that the shock load directed along one axis does not virtually cause the movement of sensing elements along the crosswise axes. Maximum stresses observed in the proposed gyroscope at any loading direction do not exceed the value allowable for silicon.
NASA Astrophysics Data System (ADS)
Annese, E.; Fujii, J.; Baldacchini, C.; Zhou, B.; Viol, C. E.; Vobornik, I.; Betti, M. G.; Rossi, G.
2008-05-01
The interaction of pentacene molecules in contact with the Cu(119) stepped surface has been directly imaged by scanning tunneling microscopy and analyzed by angle resolved photoemission spectroscopy. Interacting molecules, which are in contact with copper, generate dispersive electronic states associated with a perturbed electron charge density distribution of the molecular orbitals. In contrast, the electron charge density of molecules of the pentacene on top of the first layer, which is not in direct contact with the Cu surface, shows an intramolecular structure very similar to that of the free molecule. Our results indicate that the delocalization of the molecular states in the pentacene/Cu system is confined to the very first molecular layer at the interface.
78 FR 42727 - Airworthiness Directives; the Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-17
... available in the AD docket shortly after receipt. FOR FURTHER INFORMATION CONTACT: Ray Mei, Aerospace... . SUPPLEMENTARY INFORMATION: Comments Invited We invite you to send any written relevant data, views, or arguments... about this AD, contact Ray Mei, Aerospace Engineer, Systems and Equipment Branch, ANM-130S, FAA, Seattle...
77 FR 16432 - Airworthiness Directives; Cessna Aircraft Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-21
... CONTACT: David Fairback, Aerospace Engineer, Mechanical Systems and Propulsion Branch, ACE-116W, FAA... Fairback, Aerospace Engineer, Mechanical Systems and Propulsion Branch, ACE- 116W, FAA, Wichita Aircraft...
Visualizing multiple inter-organelle contact sites using the organelle-targeted split-GFP system.
Kakimoto, Yuriko; Tashiro, Shinya; Kojima, Rieko; Morozumi, Yuki; Endo, Toshiya; Tamura, Yasushi
2018-04-18
Functional integrity of eukaryotic organelles relies on direct physical contacts between distinct organelles. However, the entity of organelle-tethering factors is not well understood due to lack of means to analyze inter-organelle interactions in living cells. Here we evaluate the split-GFP system for visualizing organelle contact sites in vivo and show its advantages and disadvantages. We observed punctate GFP signals from the split-GFP fragments targeted to any pairs of organelles among the ER, mitochondria, peroxisomes, vacuole and lipid droplets in yeast cells, which suggests that these organelles form contact sites with multiple organelles simultaneously although it is difficult to rule out the possibilities that these organelle contacts sites are artificially formed by the irreversible associations of the split-GFP probes. Importantly, split-GFP signals in the overlapped regions of the ER and mitochondria were mainly co-localized with ERMES, an authentic ER-mitochondria tethering structure, suggesting that split-GFP assembly depends on the preexisting inter-organelle contact sites. We also confirmed that the split-GFP system can be applied to detection of the ER-mitochondria contact sites in HeLa cells. We thus propose that the split-GFP system is a potential tool to observe and analyze inter-organelle contact sites in living yeast and mammalian cells.
An ultra-bright white LED based non-contact skin cancer imaging system with polarization control
NASA Astrophysics Data System (ADS)
Günther, A.; Basu, C.; Roth, B.; Meinhardt-Wollweber, M.
2013-06-01
Early detection and excision of melanoma skin cancer is crucial for a successful therapy. Dermoscopy in direct contact with the skin is routinely used for inspection, but screening is time consuming for high-risk patients with a large number of nevi. Features like symmetry, border, color and most importantly changes like growth or depigmentation of a nevus may indicate malignancy. We present a non-contact remote imaging system for human melanocytic nevi with homogenous illumination by an ultra-bright white LED. The advantage compared to established dermoscopy systems requiring direct skin contact is that deformation of raised nevi is avoided and full-body scans of the patients may time-efficiently be obtained while they are in a lying, comfortable position. This will ultimately allow for automated screening in the future. In addition, calibration of true color rendering, which is essential for distinguishing between benign and malignant lesions and to ensure reproducibility and comparison between individual check-ups in order to follow nevi evolution is implemented as well as suppression of specular highlights on the skin surface by integration of polarizing filters. Important features of the system which will be crucial for future integration into automated systems are the possibility to record images without artifacts in combination with short exposure times which both reduce image blurring caused by patient motion.
Apparatus and method for deterministic control of surface figure during full aperture polishing
Suratwala, Tayyab Ishaq; Feit, Michael Dennis; Steele, William Augustus
2013-11-19
A polishing system configured to polish a lap includes a lap configured to contact a workpiece for polishing the workpiece; and a septum configured to contact the lap. The septum has an aperture formed therein. The radius of the aperture and radius the workpiece are substantially the same. The aperture and the workpiece have centers disposed at substantially the same radial distance from a center of the lap. The aperture is disposed along a first radial direction from the center of the lap, and the workpiece is disposed along a second radial direction from the center of the lap. The first and second radial directions may be opposite directions.
Grönroos, Mira; Parajuli, Anirudra; Laitinen, Olli H; Roslund, Marja I; Vari, Heli K; Hyöty, Heikki; Puhakka, Riikka; Sinkkonen, Aki
2018-05-29
Immune-mediated diseases have increased during the last decades in urban environments. The hygiene hypothesis suggests that increased hygiene level and reduced contacts with natural biodiversity are related to the increase in immune-mediated diseases. We tested whether short-time contact with microbiologically diverse nature-based materials immediately change bacterial diversity on human skin. We tested direct skin contact, as two volunteers rubbed their hands with sixteen soil and plant based materials, and an exposure via fabric packets filled with moss material. Skin swabs were taken before and after both exposures. Next-generation sequencing showed that exposures increased, at least temporarily, the total diversity of skin microbiota and the diversity of Acidobacteria, Actinobacteria, Bacteroidetes, Proteobacteria and Alpha-, Beta- and Gammaproteobacteria suggesting that contact with nature-based materials modify skin microbiome and increase skin microbial diversity. Until now, approaches to cure or prevent immune system disorders using microbe-based treatments have been limited to use of a few microbial species. We propose that nature-based materials with high natural diversity, such as the materials tested here, might be more effective in modifying human skin microbiome, and eventually, in reducing immune system disorders. Future studies should investigate how long-term changes in skin microbiota are achieved and if the exposure induces beneficial changes in the immune system markers. © 2018 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.
Modelling of Technological Solutions to 4th Generation DH Systems
NASA Astrophysics Data System (ADS)
Vigants, Edgars; Prodanuks, Toms; Vigants, Girts; Veidenbergs, Ivars; Blumberga, Dagnija
2017-11-01
Flue gas evaporation and condensing processes are investigated in a direct contact heat exchanger - condensing unit, which is installed after a furnace. By using equations describing processes of heat and mass transfer, as well as correlation coherences for determining wet gas parameters, a model is formed to create a no-filling, direct contact heat exchanger. Results of heating equipment modelling and experimental research on the gas condensing unit show, that the capacity of the heat exchanger increases, when return temperature of the district heating network decreases. In order to explain these alterations in capacity, the character of the changes in water vapour partial pressure, in the propelling force of mass transfer, in gas and water temperatures and in the determining parameters of heat transfer are used in this article. The positive impact on the direct contact heat exchanger by the decreased district heating (DH) network return temperature shows that introduction of the 4th generation DH system increases the energy efficiency of the heat exchanger. In order to make an assessment, the methodology suggested in the paper can be used in each particular situation.
2015-04-07
contribute to the broad dissemination of some strains after contact between local strains and imported strains. It is suspected that the reservoir for...the population. Direct contact (skin contact ) may be the main route; however, fomites also play a role in closed settings such as those experienced by...using protocols with which we have experience(23). Report of Results Nasal swab results were reported to our Point of Contact personnel (POC) who is a
Jollis, James G; Al-Khalidi, Hussein R; Roettig, Mayme L; Berger, Peter B; Corbett, Claire C; Dauerman, Harold L; Fordyce, Christopher B; Fox, Kathleen; Garvey, J Lee; Gregory, Tammy; Henry, Timothy D; Rokos, Ivan C; Sherwood, Matthew W; Suter, Robert E; Wilson, B Hadley; Granger, Christopher B
2016-08-02
Up to 50% of patients fail to meet ST-segment-elevation myocardial infarction (STEMI) guideline goals recommending a first medical contact-to-device time of <90 minutes for patients directly presenting to percutaneous coronary intervention-capable hospitals and <120 minutes for transferred patients. We sought to increase the proportion of patients treated within guideline goals by organizing coordinated regional reperfusion plans. We established leadership teams, coordinated protocols, and provided regular feedback for 484 hospitals and 1253 emergency medical services (EMS) agencies in 16 regions across the United States. Between July 2012 and December 2013, 23 809 patients presented with acute STEMI (direct to percutaneous coronary intervention hospital: 11 765 EMS transported and 6502 self-transported; 5542 transferred). EMS-transported patients differed from self-transported patients in symptom onset to first medical contact time (median, 47 versus 114 minutes), incidence of cardiac arrest (10% versus 3%), shock on admission (11% versus 3%), and in-hospital mortality (8% versus 3%; P<0.001 for all comparisons). There was a significant increase in the proportion of patients meeting guideline goals of first medical contact-to-device time, including those directly presenting via EMS (50% to 55%; P<0.001) and transferred patients (44%-48%; P=0.002). Despite regional variability, the greatest gains occurred among patients in the 5 most improved regions, increasing from 45% to 57% (direct EMS; P<0.001) and 38% to 50% (transfers; P<0.001). This Mission: Lifeline STEMI Systems Accelerator demonstration project represents the largest national effort to organize regional STEMI care. By focusing on first medical contact-to-device time, coordinated treatment protocols, and regional data collection and reporting, we were able to increase significantly the proportion of patients treated within guideline goals. © 2016 American Heart Association, Inc.
Bowman, Brent; Smith, Scott
2010-01-01
Of the key Health Plan patient satisfaction measures used in Kaiser Permanente Colorado, ease of contacting the physician's office with a medical question was consistently rated as the lowest quarterly patient satisfaction measure. Furthermore, medical office staff had become dissatisfied with their inability to contact patients who had previously left messages. In addition to the shear volume of messages, the return calls were often unanswered, leading to subsequent attempts to reach patients, creating additional work for medical office staff.DirectConnect-the project name for a system and set of processes focused on improving patient satisfaction with the ability to contact Primary Care delivery teams by telephone-focuses on isolating medical advice calls from the other types of calls handled by the centralized Call Center. The system identifies the patient using his/her unique electronic medical record number, then automatically routes medical advice calls directly to the appropriate Primary Care Physician (PCP) or staff. The clinician may then evaluate and respond to the patient's need quickly, thus managing more of their panel's requests in real time.How is DirectConnect different from simply having the patient contact their PCP's office directly? The primary difference is "one-number" convenience that allows all patients to dial one number to access their PCP's team. In addition, calls are routed to various staff as available to reduce long telephone queues and wait times.The DirectConnect system has resulted in statistically significant improvement in key service quality measures. Patient satisfaction improved from a pre-implementation nine quarter mean of 55.9% to a post-implementation 12 quarter mean of 70.2%. Fourteen percent to 17% of all Primary Care calls are now handled by the patient's home medical office team, creating a 54% improvement in the centralized Call Center's speed of answering calls in the first quarter post implementation-making no additions to medical office staffing levels. The efficiencies gained by directly connecting medical advice-seeking patients with their Primary Care team resulted in an estimated savings of 198 and 247 cumulative hours per week in unnecessary telephone work for Call Center and medical office staff regionwide.
77 FR 18914 - National Motor Vehicle Title Information System (NMVTIS): Technical Corrections
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-29
... 1121-AA79 National Motor Vehicle Title Information System (NMVTIS): Technical Corrections AGENCY... (OJP) is promulgating this direct final rule for its National Motor Vehicle Title Information System... INFORMATION CONTACT paragraph. II. Background The National Motor Vehicle Title Information System was...
Apparatus and method for deterministic control of surface figure during full aperture pad polishing
DOE Office of Scientific and Technical Information (OSTI.GOV)
Suratwala, Tayyab Ishaq; Feit, Michael Douglas; Steele, William Augustus
A polishing system configured to polish a lap includes a lap configured to contact a workpiece for polishing the workpiece; and a septum configured to contact the lap. The septum has an aperture formed therein. The radius of the aperture and radius the workpiece are substantially the same. The aperture and the workpiece have centers disposed at substantially the same radial distance from a center of the lap. The aperture is disposed along a first radial direction from the center of the lap, and the workpiece is disposed along a second radial direction from the center of the lap. Themore » first and second radial directions may be opposite directions.« less
Ryu, DongHyun; Kim, Yong Jae; Kim, Seon Il; Hong, Hyeonaug; Ahn, Hyun S.
2018-01-01
Photosynthesis converts solar energy to electricity in a highly efficient manner. Since only water is needed as fuel for energy conversion, this highly efficient energy conversion process has been rigorously investigated. In particular, photosynthetic apparatus, such as photosystem II (PSII), photosystem I (PSI), or thylakoids, have been isolated from various plants to construct bio-hybrid anodes. Although PSII or PSI decorated anodes have shown potentials, there still remain challenges, such as poor stability of PSII-based systems or need for electron donors other than water molecules of PSI-based systems. Thylakoid membranes are relatively stable after isolation and they contain all the necessary photosynthetic apparatus including the PSII and PSI. To increase electrical connections between thylakoids and anodes, nanomaterials such as carbon nanotubes, nanowires, nanoparticles, or graphene have been employed. However, since they rely on the secondary electrical connections between thylakoids and anodes; it is desired to achieve larger direct contacts between them. Here, we aimed to develop micro-pillar (MP) array anodes to maximize direct contact with thylakoids. The thylakoid morphology was analyzed and the MP array was designed to maximize direct contact with thylakoids. The performance of MP anodes and a photosynthetic fuel cell based on MP electrodes was demonstrated and analyzed. PMID:29587387
Code of Federal Regulations, 2010 CFR
2010-07-01
... Treasury security into my TreasuryDirect ® account from another book-entry system? 363.206 Section 363.206... transfer your marketable Treasury security from the commercial book-entry system by contacting the..., DEPARTMENT OF THE TREASURY BUREAU OF THE PUBLIC DEBT REGULATIONS GOVERNING SECURITIES HELD IN TREASURYDIRECT...
76 FR 59392 - Notice of Intent To Grant Exclusive Patent License; Enhanced Energy Group, LLC
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-26
... inventions, and they are covered by U.S. Patent No. 7,926,275: Closed Brayton Cycle Direct Contact Reactor/ Storage Tank With Chemical Scrubber.//U.S. Patent No. 7,926,276: Closed Cycle Brayton Propulsion System With Direct Heat Transfer.//U.S. Patent No. 7,937,930: Semiclosed Brayton Cycle Power System With...
Lithium compensation for full cell operation
Xiao, Jie; Zheng, Jianming; Chen, Xilin; Lu, Dongping; Liu, Jun; Jiguang, Jiguang
2016-05-17
Disclosed herein are embodiments of a lithium-ion battery system comprising an anode, an anode current collector, and a layer of lithium metal in contact with the current collector, but not in contact with the anode. The lithium compensation layer dissolves into the electrolyte to compensate for the loss of lithium ions during usage of the full cell. The specific placement of the lithium compensation layer, such that there is no direct physical contact between the lithium compensation layer and the anode, provides certain advantages.
[The use of an opect optic system in neurosurgical practice].
Kalinovskiy, A V; Rzaev, D A; Yoshimitsu, K
2018-01-01
Modern neurosurgical practice is impossible without access to various information sources. The use of MRI and MSCT data during surgery is an integral part of the neurosurgeon's daily practice. Devices capable of managing an image viewer system without direct contact with equipment simplify working in the operating room. To test operation of a non-contact MRI and MSCT image viewer system in the operating room and to evaluate the system effectiveness. An Opect non-contact image management system developed at the Tokyo Women's Medical University was installed in one of the operating rooms of the Novosibirsk Federal Center of Neurosurgery in 2014. In 2015, the Opect system was used by operating surgeons in 73 surgeries performed in the same operating room. The system effectiveness was analyzed based on a survey of surgeons. The non-contact image viewer system occurred to be easy-to-learn for the personnel to operate this system, easy-to-manage it, and easy-to-present visual information during surgery. Application of the Opect system simplifies work with neuroimaging data during surgery. The surgeon can independently view series of relevant MRI and MSCT scans without any assistance.
Countercurrent direct contact heat exchange process and system
Wahl, III, Edward F.; Boucher, Frederic B.
1979-01-01
Recovery of energy from geothermal brines and other hot water sources by direct contact heat exchange with a working fluid, such as a hydrocarbon working fluid, e.g. isobutane. The process and system consists of a plurality of stages, each stage including mixing and settling units. In the first stage, hot brine and arm working fluid are intimately mixed and passed into a settler wherein the brine settles to the bottom of the settler and the hot working fluid rises to the top. The hot working fluid is passed to a heat engine or turbine to produce work and the working fluid is then recycled back into the system. The system is comprised of a series of stages each containing a settler and mixer, and wherein the working fluid and the brine flow in a countercurrent manner through the stages to recover the heat from the brine in increments and raise the temperature of the working fluid in increments.
Biocompatibility and light transmission of liposomal lenses.
Danion, Anne; Doillon, Charles J; Giasson, Claude J; Djouahra, Saliha; Sauvageau, Patrick; Paradis, Renée; Vermette, Patrick
2007-10-01
To validate the biocompatibility and transmittance properties of contact lenses bearing intact liposomes. These liposomal lenses loaded with therapeutics can be used as ophthalmic drug delivery systems. The biocompatibility of soft contact lenses, coated with liposomes was evaluated through in vitro direct and indirect cytocompatibility assays on human corneal epithelial cells, on reconstructed human corneas and on ex vivo rabbit corneas. The direct and indirect transmission spectra of liposome-covered lenses were also evaluated to test if they transmit all wavelengths of the ultraviolet-visible spectrum, to thereby fulfill their optical function, without gross alteration of the colors perception and with a minimum of light dispersion. Contact lenses bearing layers of stable liposomes did not induce any significant changes in cell viability and in cell growth, compared with lenses bearing no liposome. Elution assays revealed that no cytotoxic compound leaks from the lenses whether bearing liposomes or not. Histological analyses of reconstructed human corneas and ex vivo rabbit corneas directly exposed to liposomal lenses revealed neither alteration to the cell nor to the tissue structures. Contact lenses bearing layers of liposomes did not significantly affect light transmission compared with control lenses without liposome at the wavelength of maximal photopic sensitivity, i.e., 550 nm. In addition, the contact lenses afford more eye protection in the ultraviolet spectrum, compared with the control lenses. Liposomal contact lenses are biocompatible and their transmittance properties are not affected in the visible light range.
Distributed Tactical Decision Support by Using Real-Time Database System
1987-11-01
appendix A and detailed in depth in the Advanced Combat Direction System Specification (reference 5). The assumption is that ’ ime 0 (TO) of any contact...CONSTELLATION LAUNCH I F14A CAPM 330 350 10000 STOP At simulated engagement minute 30. the following orders are next submitted to the event generator...time of contact (ETC). There is the assumption in the ETC calculation that COURSE will change such that the new report would be on a dead- reckoning
Improvements in Topical Ocular Drug Delivery Systems: Hydrogels and Contact Lenses.
Ribeiro, Andreza Maria; Figueiras, Ana; Veiga, Francisco
2015-01-01
Conventional ophthalmic systems present very low corneal systemic bioavailability due to the nasolacrimal drainage and the difficulty to deliver the drug in the posterior segment of ocular tissue. For these reasons, recent advances have focused on the development of new ophthalmic drug delivery systems. This review provides an insight into the various constraints associated with ocular drug delivery, summarizes recent findings in soft contact lenses (SCL) and the applications of novel pharmaceutical systems for ocular drug delivery. Among the new therapeutic approaches in ophthalmology, SCL are novel continuous-delivery systems, providing high and sustained levels of drugs to the cornea. The tendency of research in ophthalmic drug delivery systems development are directed towards a combination of several technologies (bio-inspired and molecular imprinting techniques) and materials (cyclodextrins, surfactants, specific monomers). There is a tendency to develop systems which not only prolong the contact time of the vehicle at the ocular surface, but also at the same time slow down the clearance of the drug. Different materials can be applied during the development of contact lenses and can be combined with natural inspired strategies of drug immobilization and release, providing successful tools for ocular drug delivery systems.
Direct assembling methodologies for high-throughput bioscreening
Rodríguez-Dévora, Jorge I.; Shi, Zhi-dong; Xu, Tao
2012-01-01
Over the last few decades, high-throughput (HT) bioscreening, a technique that allows rapid screening of biochemical compound libraries against biological targets, has been widely used in drug discovery, stem cell research, development of new biomaterials, and genomics research. To achieve these ambitions, scaffold-free (or direct) assembly of biological entities of interest has become critical. Appropriate assembling methodologies are required to build an efficient HT bioscreening platform. The development of contact and non-contact assembling systems as a practical solution has been driven by a variety of essential attributes of the bioscreening system, such as miniaturization, high throughput, and high precision. The present article reviews recent progress on these assembling technologies utilized for the construction of HT bioscreening platforms. PMID:22021162
Localization of a bacterial cytoplasmic receptor is dynamic and changes with cell-cell contacts
Mauriello, Emilia M. F.; Astling, David P.; Sliusarenko, Oleksii; Zusman, David R.
2009-01-01
Directional motility in the gliding bacterium Myxococcus xanthus requires controlled cell reversals mediated by the Frz chemosensory system. FrzCD, a cytoplasmic chemoreceptor, does not form membrane-bound polar clusters typical for most bacteria, but rather cytoplasmic clusters that appear helically arranged and span the cell length. The distribution of FrzCD in living cells was found to be dynamic: FrzCD was localized in clusters that continuously changed their size, number, and position. The number of FrzCD clusters was correlated with cellular reversal frequency: fewer clusters were observed in hypo-reversing mutants and additional clusters were observed in hyper-reversing mutants. When moving cells made side-to-side contacts, FrzCD clusters in adjacent cells showed transient alignments. These events were frequently followed by one of the interacting cells reversing. These observations suggest that FrzCD detects signals from a cell contact-sensitive signaling system and then re-localizes as it directs reversals to distributed motility engines. PMID:19273862
Geysers advanced direct contact condenser research
DOE Office of Scientific and Technical Information (OSTI.GOV)
Henderson, J.; Bahning, T.; Bharathan, D.
1997-12-31
The first geothermal application of the Advanced Direct Contact Condenser (ADCC) technology developed by the National Renewable Energy Laboratory (NREL) is now operational and is being tested at The Geysers Power Plant Unit 11. This major research effort is being supported through the combined efforts of NREL, The Department of Energy (DOE), and Pacific Gas and Electric (PG&E). NREL and PG&E have entered into a Cooperative Research And Development Agreement (CRADA) for a project to improve the direct-contact condenser performance at The Geysers Power Plant. This project is the first geothermal adaptation of an advanced condenser design developed for themore » Ocean Thermal Energy Conversion (OTEC) systems. PG&E expects this technology to improve power plant performance and to help extend the life of the steam field by using steam more efficiently. In accordance with the CRADA, no money is transferred between the contracting parties. In this case the Department of Energy is funding NREL for their efforts in this project and PG&E is contributing funds in kind. Successful application of this technology at The Geysers will provide a basis for NREL to continue to develop this technology for other geothermal and fossil power plant systems.« less
Yanke, Eric; Zellmer, Caroline; Van Hoof, Sarah; Moriarty, Helene; Carayon, Pascale; Safdar, Nasia
2015-01-01
Background Achieving and sustaining high levels of healthcare worker (HCW) compliance with contact isolation precautions is challenging. The aim of this study was to determine HCW work system barriers to, and facilitators of, adherence to contact isolation for patients with suspected or confirmed Clostridium difficile infection (CDI) using a human factors and systems engineering approach. Methods Prospective cohort study from September 2013 to November 2013 at a large academic medical center (hospital A) and an affiliated Veterans Administration (VA) hospital (hospital B). A human factors engineering (HFE) model for patient safety – the Systems Engineering Initiative for Patient Safety (SEIPS) model – was used to guide work system analysis and direct observation data collection. 288 observations were conducted. HCWs and visitors were assessed for compliance with all components of contact isolation precautions (hand hygiene, gowning, and gloving) before and after patient contact. Time required to complete contact isolation precautions was measured and adequacy of contact isolation supplies was assessed. Results Full compliance with contact isolation precautions was low at both hospitals: hospital A, 7%; hospital B, 22%. Lack of appropriate hand hygiene prior to room entry (Compliance: hospital A, 18%; hospital B, 29%) was the most common reason for lack of full compliance. More time was required for full compliance as compared to compliance with no components of contact isolation precautions before patient room entry, inside patient room, and after patient room exit (59.9 sec vs. 3.2 sec; P < .001; 507.3 sec vs. 149.7 sec; P = .006; 15.2 sec vs. 1.3 sec; P < .001). Compliance was lower when contact isolation supplies were inadequate (4% vs. 16%; P = .005). Conclusions Adherence to contact isolation precautions for CDI is a complex, time-consuming process. HFE analysis indicates multiple work system components serve as barriers and facilitators to full compliance with contact isolation precautions and should be addressed further to prevent CDI. PMID:25728149
Yanke, Eric; Zellmer, Caroline; Van Hoof, Sarah; Moriarty, Helene; Carayon, Pascale; Safdar, Nasia
2015-03-01
Achieving and sustaining high levels of health care worker (HCW) compliance with contact isolation precautions is challenging. The aim of this study was to determine HCW work system barriers to and facilitators of adherence to contact isolation for patients with suspected or confirmed Clostridium difficile infection (CDI) using a human factors and systems engineering approach. This prospective cohort study took place between September 2013 and November 2013 at a large academic medical center (hospital A) and an affiliated Veterans Administration hospital (hospital B). A human factors engineering (HFE) model for patient safety, the Systems Engineering Initiative for Patient Safety model, was used to guide work system analysis and direct observation data collection. There were 288 observations conducted. HCWs and visitors were assessed for compliance with all components of contact isolation precautions (hand hygiene, gowning, and gloving) before and after patient contact. Time required to complete contact isolation precautions was measured, and adequacy of contact isolation supplies was assessed. Full compliance with contact isolation precautions was low at both hospitals A (7%) and B (22%). Lack of appropriate hand hygiene prior to room entry (compliance for hospital A: 18%; compliance for hospital B: 29%) was the most common reason for lack of full compliance. More time was required for full compliance compared with compliance with no components of contact isolation precautions before patient room entry, inside patient room, and after patient room exit (59.9 vs 3.2 seconds, P < .001; 507.3 vs 149.7 seconds, P = .006; 15.2 vs 1.3 seconds, P < .001, respectively). Compliance was lower when contact isolation supplies were inadequate (4% vs 16%, P = .005). Adherence to contact isolation precautions for CDI is a complex, time-consuming process. HFE analysis indicates that multiple work system components serve as barriers and facilitators to full compliance with contact isolation precautions and should be addressed further to prevent CDI. Published by Elsevier Inc.
NASA Astrophysics Data System (ADS)
Xuan, Yue
Background. Soft materials such as polymers and soft tissues have diverse applications in bioengineering, medical care, and industry. Quantitative mechanical characterization of soft materials at multiscales is required to assure that appropriate mechanical properties are presented to support the normal material function. Indentation test has been widely used to characterize soft material. However, the measurement of in situ contact area is always difficult. Method of Approach. A transparent indenter method was introduced to characterize the nonlinear behaviors of soft materials under large deformation. This approach made the direct measurement of contact area and local deformation possible. A microscope was used to capture the contact area evolution as well as the surface deformation. Based on this transparent indenter method, a novel transparent indentation measurement systems has been built and multiple soft materials including polymers and pericardial tissue have been characterized. Seven different indenters have been used to study the strain distribution on the contact surface, inner layer and vertical layer. Finite element models have been built to simulate the hyperelastic and anisotropic material behaviors. Proper material constants were obtained by fitting the experimental results. Results.Homogeneous and anisotropic silicone rubber and porcine pericardial tissue have been examined. Contact area and local deformation were measured by real time imaging the contact interface. The experimental results were compared with the predictions from the Hertzian equations. The accurate measurement of contact area results in more reliable Young's modulus, which is critical for soft materials. For the fiber reinforced anisotropic silicone rubber, the projected contact area under a hemispherical indenter exhibited elliptical shape. The local surface deformation under indenter was mapped using digital image correlation program. Punch test has been applied to thin films of silicone rubber and porcine pericardial tissue and results were analyzed using the same method. Conclusions. The transparent indenter testing system can effectively reduce the material properties measurement error by directly measuring the contact radii. The contact shape can provide valuable information for the anisotropic property of the material. Local surface deformation including contact surface, inner layer and vertical plane can be accurately tracked and mapped to study the strain distribution. The potential usage of the transparent indenter measurement system to investigate biological and biomaterials was verified. The experimental data including the real-time contact area combined with the finite element simulation would be powerful tool to study mechanical properties of soft materials and their relation to microstructure, which has potential in pathologies study such as tissue repair and surgery plan. Key words: transparent indenter, large deformation, soft material, anisotropic.
Three degree-of-freedom force feedback control for robotic mating of umbilical lines
NASA Technical Reports Server (NTRS)
Fullmer, R. Rees
1988-01-01
The use of robotic manipulators for the mating and demating of umbilical fuel lines to the Space Shuttle Vehicle prior to launch is investigated. Force feedback control is necessary to minimize the contact forces which develop during mating. The objective is to develop and demonstrate a working robotic force control system. Initial experimental force control tests with an ASEA IRB-90 industrial robot using the system's Adaptive Control capabilities indicated that control stability would by a primary problem. An investigation of the ASEA system showed a 0.280 second software delay between force input commands and the output of command voltages to the servo system. This computational delay was identified as the primary cause of the instability. Tests on a second path into the ASEA's control computer using the MicroVax II supervisory computer show that time delay would be comparable, offering no stability improvement. An alternative approach was developed where the digital control system of the robot was disconnected and an analog electronic force controller was used to control the robot's servosystem directly, allowing the robot to use force feedback control while in rigid contact with a moving three-degree-of-freedom target. An alternative approach was developed where the digital control system of the robot was disconnected and an analog electronic force controller was used to control the robot's servo system directly. This method allowed the robot to use force feedback control while in rigid contact with moving three degree-of-freedom target. Tests on this approach indicated adequate force feedback control even under worst case conditions. A strategy to digitally-controlled vision system was developed. This requires switching between the digital controller when using vision control and the analog controller when using force control, depending on whether or not the mating plates are in contact.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-02-19
... Airworthiness Directives; British Aerospace Regional Aircraft Model Jetstream Series 3101 and Jetstream Model... available in the AD docket shortly after receipt. FOR FURTHER INFORMATION CONTACT: Taylor Martin, Aerospace... AD docket. Relevant Service Information BAE Systems has issued British Aerospace Jetstream Series...
Control of crystal growth in water purification by directional freeze crystallization
NASA Technical Reports Server (NTRS)
Conlon, William M. (Inventor)
1996-01-01
A Directional Freeze Crystallization system employs an indirect contact heat exchanger to freeze a fraction of liquid to be purified. The unfrozen fraction is drained away and the purified frozen fraction is melted. The heat exchanger must be designed in accordance with a Growth Habit Index to achieve efficient separation of contaminants. If gases are dissolved in the liquid, the system must be pressurized.
Cheng, V C C; Chau, P H; Lee, W M; Ho, S K Y; Lee, D W Y; So, S Y C; Wong, S C Y; Tai, J W M; Yuen, K Y
2015-07-01
Unlike direct contact with patients' body, hand hygiene practice is often neglected by healthcare workers (HCWs) and visitors after contact with patients' environment. Contact with hospital environmental items may increase risk of pathogen transmission. To enumerate the number of hand-touch contacts by patients, HCWs and visitors with any hospital environmental items. All contact-episodes between person and item were recorded by direct observation in a six-bed cubicle of acute wards for 33 working days. High-touch and mutual-touch items with high contact frequencies by HCWs, patients, and visitors were analysed. In total, 1107 person-episodes with 6144 contact-episodes were observed in 66 observation hours (average: 16.8 person-episodes and 93.1 contact-episodes per hour). Eight of the top 10 high-touch items, including bedside rails, bedside tables, patients' bodies, patients' files, linen, bed curtains, bed frames, and lockers were mutually touched by HCWs, patients, and visitors. Bedside rails topped the list with 13.6 contact-episodes per hour (mean), followed by bedside tables (12.3 contact-episodes per hour). Using patients' body contacts as a reference, it was found that medical staff and nursing staff contacted bedside tables [rate ratio (RR): 1.741, 1.427, respectively] and patients' files (RR: 1.358, 1.324, respectively) more than patients' bodies, and nursing staff also contacted bedside rails (RR: 1.490) more than patients' bodies. Patients' surroundings may be links in the transmission of nosocomial infections because many are frequently touched and mutually contacted by HCWs, patients, and visitors. Therefore, the focus of hand hygiene education, environmental disinfection, and other system changes should be enhanced with respect to high-touch and mutual-touch items. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.
[Eye contact in adult patients with Asperger syndrome].
Roy, M; Wolfgang, D
2015-05-01
It is unclear if individuals with autism spectrum disorders rarely hold direct eye contact because eyes are unimportant for them, or if it is actively avoided. The aim of the current investigation was to gain a better understanding for their views on direct eye contact by exploring adult patients with Asperger syndrome. 63 adult patients with Asperger syndrome (28 females, 35 males, 21 - 62 years old) were explored about using and sensing direct eye contact by means of a standardised questionnaire. 87 % of investigated patients depict direct eye contact as being disagreeable. They describe it as arduous and distracting. Therefore they mostly actively avoid direct eye contact. The here gained knowledge about aversion towards direct eye contact in individuals with autism should lead to a stronger understanding and acceptance of this problem in the non-autistic population. © Georg Thieme Verlag KG Stuttgart · New York.
Solid state potentiometric gaseous oxide sensor
NASA Technical Reports Server (NTRS)
Wachsman, Eric D. (Inventor); Azad, Abdul Majeed (Inventor)
2003-01-01
A solid state electrochemical cell (10a) for measuring the concentration of a component of a gas mixture (12) includes first semiconductor electrode (14) and second semiconductor electrode (16) formed from first and second semiconductor materials, respectively. The materials are selected so as to undergo a change in resistivity upon contacting a gas component, such as CO or NO. An electrolyte (18) is provided in contact with the first and second semiconductor electrodes. A reference cell can be included in contact with the electrolyte. Preferably, a voltage response of the first semiconductor electrode is opposite in slope direction to that of the second semiconductor electrode to produce a voltage response equal to the sum of the absolute values of the control system uses measured pollutant concentrations to direct adjustment of engine combustion conditions.
Nguyen, Elizabeth; Chen, Timothy F; O'Reilly, Claire L
2012-07-01
Contact with mental health consumers has shown to be a promising strategy to address mental health stigma, particularly in the context of pharmacy education. This research aimed to compare the effectiveness of a direct (face-to-face) contact intervention with an indirect (film based) contact intervention in reducing the mental health stigma of pharmacy students. A two-group, non-randomized, comparative study was conducted with third year pharmacy students (n = 198) allocated to the direct contact arm and fourth year pharmacy students (n = 278) allocated to the indirect contact arm. Baseline and immediate post-intervention data were collected using a validated 39 item survey instrument to assess the impact of the interventions on mental health stigma as well as attitudes towards providing mental health pharmaceutical services. Participants in the direct contact group showed a significant improvement in 37 out of 39 survey items and participants in the indirect contact group showed a significant improvement in 27 out of 39 items (P < 0.05). While direct contact had a stronger impact than indirect contact for 22 items (P < 0.05), for numerous key measures of mental health stigma the impact of the two contact interventions was equivalent. Both indirect and direct contact may positively impact mental health stigma. While the strength of the stigma-change process may be heightened by face-to-face interactions, the largely positive impact of indirect contact suggests that stigma reduction may depend less on the medium of contact but more on the transcendent messages contributed by the consumers facilitating the contact experience.
21 CFR 882.1570 - Powered direct-contact temperature measurement device.
Code of Federal Regulations, 2012 CFR
2012-04-01
... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Powered direct-contact temperature measurement... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1570 Powered direct-contact temperature measurement device. (a) Identification. A powered direct...
21 CFR 882.1570 - Powered direct-contact temperature measurement device.
Code of Federal Regulations, 2014 CFR
2014-04-01
... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Powered direct-contact temperature measurement... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1570 Powered direct-contact temperature measurement device. (a) Identification. A powered direct...
21 CFR 882.1570 - Powered direct-contact temperature measurement device.
Code of Federal Regulations, 2013 CFR
2013-04-01
... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Powered direct-contact temperature measurement... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1570 Powered direct-contact temperature measurement device. (a) Identification. A powered direct...
NASA Astrophysics Data System (ADS)
Dewell, Larry D.; Tajdaran, Kiarash; Bell, Raymond M.; Liu, Kuo-Chia; Bolcar, Matthew R.; Sacks, Lia W.; Crooke, Julie A.; Blaurock, Carl
2017-09-01
The need for high payload dynamic stability and ultra-stable mechanical systems is an overarching technology need for large space telescopes such as the Large Ultraviolet / Optical / Infrared (LUVOIR) Surveyor. Wavefront error stability of less than 10 picometers RMS of uncorrected system WFE per wavefront control step represents a drastic performance improvement over current space-based telescopes being fielded. Previous studies of similar telescope architectures have shown that passive telescope isolation approaches are hard-pressed to meet dynamic stability requirements and usually involve complex actively-controlled elements and sophisticated metrology. To meet these challenging dynamic stability requirements, an isolation architecture that involves no mechanical contact between telescope and the host spacecraft structure has the potential of delivering this needed performance improvement. One such architecture, previously developed by Lockheed Martin called Disturbance Free Payload (DFP), is applied to and analyzed for LUVOIR. In a noncontact DFP architecture, the payload and spacecraft fly in close proximity, and interact via non-contact actuators to allow precision payload pointing and isolation from spacecraft vibration. Because disturbance isolation through non-contact, vibration isolation down to zero frequency is possible, and high-frequency structural dynamics of passive isolators are not introduced into the system. In this paper, the system-level analysis of a non-contact architecture is presented for LUVOIR, based on requirements that are directly traceable to its science objectives, including astrophysics and the direct imaging of habitable exoplanets. Aspects of architecture and how they contribute to system performance are examined and tailored to the LUVOIR architecture and concept of operation.
Effect of Yttrium on the Microstructure and Properties of Pt-Ir Electrical Contact Materials
NASA Astrophysics Data System (ADS)
Wang, Saibei; Sun, Yong; Wang, Song; Peng, Mingjun; Liu, Manmen; Duan, Yonghua; Chen, Yongtai; Yang, Youcai; Chen, Song; Li, Aikun; Xie, Ming
2017-10-01
The Pt-10Ir and Pt-10Ir-1Y were prepared by high frequency induction melting, then the samples were obtained by powder metallurgy, hot extrusion and drawing. The influence of Y addition on microstructure and electrical contact properties of Pt-10Ir alloy has been investigated by using optical microscopy, SEM, electronic balance and the contact material test system. The results show that the addition of Y leads to the micro-structural refinement and directional change of material transfer, but has almost no influence on erosion morphology.
[Nickel contact dermatitis. A ring signal in actual pathology].
Cherciu, Mirela; Zbranca, Anca
2004-01-01
Contact dermatitis produced by nickel is extremely common in women by earrings or other items of jewelry which contain nickel. Areas of involvement are under rings, bracelets, watches, spectacle frames, coins in pockets, jeans studs and other sites of direct contact with the metal. The frequency of nickel dermatitis is increasing in the male population and this may be due of body-piercing or professional contact in the field of metallic constructions. The treatment is difficult because of the presence of nickel in so many substances, things or even food. The management of contact dermatitis include the reduction or elimination of the allergen, the use of topical or systemic steroids, oral desensitisation and use of nickel in selected cases.
Bowman, Brent; Smith, Scott
2010-01-01
Of the key Health Plan patient satisfaction measures used in Kaiser Permanente Colorado, ease of contacting the physician's office with a medical question was consistently rated as the lowest quarterly patient satisfaction measure. Furthermore, medical office staff had become dissatisfied with their inability to contact patients who had previously left messages. In addition to the shear volume of messages, the return calls were often unanswered, leading to subsequent attempts to reach patients, creating additional work for medical office staff. DirectConnect—the project name for a system and set of processes focused on improving patient satisfaction with the ability to contact Primary Care delivery teams by telephone—focuses on isolating medical advice calls from the other types of calls handled by the centralized Call Center. The system identifies the patient using his/her unique electronic medical record number, then automatically routes medical advice calls directly to the appropriate Primary Care Physician (PCP) or staff. The clinician may then evaluate and respond to the patient's need quickly, thus managing more of their panel's requests in real time. How is DirectConnect different from simply having the patient contact their PCP's office directly? The primary difference is “one-number” convenience that allows all patients to dial one number to access their PCP's team. In addition, calls are routed to various staff as available to reduce long telephone queues and wait times. The DirectConnect system has resulted in statistically significant improvement in key service quality measures. Patient satisfaction improved from a pre-implementation nine quarter mean of 55.9% to a post-implementation 12 quarter mean of 70.2%. Fourteen percent to 17% of all Primary Care calls are now handled by the patient's home medical office team, creating a 54% improvement in the centralized Call Center's speed of answering calls in the first quarter post implementation—making no additions to medical office staffing levels. The efficiencies gained by directly connecting medical advice-seeking patients with their Primary Care team resulted in an estimated savings of 198 and 247 cumulative hours per week in unnecessary telephone work for Call Center and medical office staff regionwide. PMID:20740112
NASA Astrophysics Data System (ADS)
Yang, Zhenyin
Metal-contact MEMS switches hold great promise for implementing agile radio frequency (RF) systems because of their small size, low fabrication cost, low power consumption, wide operational band, excellent isolation and exceptionally low signal insertion loss. Gold is often utilized as a contact material for metal-contact MEMS switches due to its excellent electrical conductivity and corrosion resistance. However contact wear and stiction are the two major failure modes for these switches due to its material softness and high surface adhesion energy. To strengthen the contact material, pure gold was alloyed with other metal elements. We designed and constructed a new micro-contacting test facility that closely mimic the typical MEMS operation and utilized this facility to efficiently evaluate optimized contact materials. Au-Ni binary alloy system as the candidate contact material for MEMS switches was systematically investigated. A correlation between contact material properties (etc. microstructure, micro-hardness, electrical resistivity, topology, surface structures and composition) and micro-contacting performance was established. It was demonstrated nano-scale graded two-phase Au-Ni film could possibly yield an improved device performance. Gold micro-contact degradation mechanisms were also systematically investigated by running the MEMS switching tests under a wide range of test conditions. According to our quantitative failure analysis, field evaporation could be the dominant failure mode for highfield (> critical threshold field) hot switching; transient thermal-assisted wear could be the dominant failure mode for low-field hot switching; on the other hand, pure mechanical wear and steady current heating (1 mA) caused much less contact degradation in cold switching tests. Results from low-force (50 muN/micro-contact), low current (0.1 mA) tests on real MEMS switches indicated that continuous adsorbed films from ambient air could degrade the switch contact resistance. Our work also contributes to the field of general nano-science and technology by resolving the transfer directionality of field evaporation of gold in atomic force microscope (AFM)/scanning tunneling microscope (STM).
Contact detection for nanomanipulation in a scanning electron microscope.
Ru, Changhai; To, Steve
2012-07-01
Nanomanipulation systems require accurate knowledge of the end-effector position in all three spatial coordinates, XYZ, for reliable manipulation of nanostructures. Although the images acquired by a scanning electron microscope (SEM) provide high resolution XY information, the lack of depth information in the Z-direction makes 3D nanomanipulation time-consuming. Existing approaches for contact detection of end-effectors inside SEM typically utilize fragile touch sensors that are difficult to integrate into a nanomanipulation system. This paper presents a method for determining the contact between an end-effector and a target surface during nanomanipulation inside SEM, purely based on the processing of SEM images. A depth-from-focus method is used in the fast approach of the end-effector to the substrate, followed by fine contact detection. Experimental results demonstrate that the contact detection approach is capable of achieving an accuracy of 21.5 nm at 50,000× magnification while inducing little end-effector damage. Copyright © 2012 Elsevier B.V. All rights reserved.
The Extended Contact Hypothesis: A Meta-Analysis on 20 Years of Research.
Zhou, Shelly; Page-Gould, Elizabeth; Aron, Arthur; Moyer, Anne; Hewstone, Miles
2018-04-01
According to the extended contact hypothesis, knowing that in-group members have cross-group friends improves attitudes toward this out-group. This meta-analysis covers the 20 years of research that currently exists on the extended contact hypothesis, and consists of 248 effect sizes from 115 studies. The aggregate relationship between extended contact and intergroup attitudes was r = .25, 95% confidence interval (CI) = [.22, .27], which reduced to r = .17, 95% CI = [.14, .19] after removing direct friendship's contribution; these results suggest that extended contact's hypothesized relationship to intergroup attitudes is small-to-medium and exists independently of direct friendship. This relationship was larger when extended contact was perceived versus actual, highlighting the importance of perception in extended contact. Current results on extended contact mostly resembled their direct friendship counterparts, suggesting similarity between these contact types. These unique insights about extended contact and its relationship with direct friendship should enrich and spur growth within this literature.
Christ, Oliver; Hewstone, Miles; Tausch, Nicole; Wagner, Ulrich; Voci, Alberto; Hughes, Joanne; Cairns, Ed
2010-12-01
Cross-group friendships (the most effective form of direct contact) and extended contact (i.e., knowing ingroup members who have outgroup friends) constitute two of the most important means of improving outgroup attitudes. Using cross-sectional and longitudinal samples from different intergroup contexts, this research demonstrates that extended contact is most effective when individuals live in segregated neighborhoods having only few, or no, direct friendships with outgroup members. Moreover, by including measures of attitudes and behavioral intentions the authors showed the broader impact of these forms of contact, and, by assessing attitude certainty as one dimension of attitude strength, they tested whether extended contact can lead not only to more positive but also to stronger outgroup orientations. Cross-sectional data showed that direct contact was more strongly related to attitude certainty than was extended contact, but longitudinal data showed both forms of contact affected attitude certainty in the long run.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-01-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses. PMID:28447604
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics.
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-27
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics
NASA Astrophysics Data System (ADS)
Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung
2017-04-01
Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.
NASA Astrophysics Data System (ADS)
Habu, K.; Kaminohara, S.; Kimoto, T.; Kawagoe, A.; Sumiyoshi, F.; Okamoto, H.
2010-11-01
We have developed a new monitoring system to detect an unusual event in the superconducting coils without direct contact on the coils, using Poynting's vector method. In this system, the potential leads and pickup coils are set around the superconducting coils to measure local electric and magnetic fields, respectively. By measuring the sets of magnetic and electric fields, the Poynting's vectors around the coil can be obtained. An unusual event in the coil can be detected as the result of the change of the Poynting's vector. This system has no risk of the voltage breakdown which may happen with the balance voltage method, because there is no need of direct contacts on the coil windings. In a previous paper, we have demonstrated that our system can detect the normal transitions in the Bi-2223 coil without direct contact on the coil windings by using a small test system. For our system to be applied to practical devices, it is necessary for the early detection of an unusual event in the coils to be able to detect local normal transitions in the coils. The signal voltages of the small sensors to measure local magnetic and electric fields are small. Although the increase in signals of the pickup coils is attained easily by an increase in the number of turns of the pickup coils, an increase in the signals of the potential lead is not easily attained. In this paper, a new method to amplify the signal of local electric fields around the coil is proposed. The validity of the method has been confirmed by measuring local electric fields around the Bi-2223 coil.
Dove, Simon L.; Hochschild, Ann
2001-01-01
A number of transcriptional regulators mediate their effects through direct contact with the ς70 subunit of Escherichia coli RNA polymerase (RNAP). In particular, several regulators have been shown to contact a C-terminal portion of ς70 that harbors conserved region 4. This region of ς contains a putative helix-turn-helix DNA-binding motif that contacts the −35 element of ς70-dependent promoters directly. Here we report the use of a recently developed bacterial two-hybrid system to study the interaction between the putative anti-ς factor Rsd and the ς70 subunit of E. coli RNAP. Using this system, we found that Rsd can interact with an 86-amino-acid C-terminal fragment of ς70 and also that amino acid substitution R596H, within region 4 of ς70, weakens this interaction. We demonstrated the specificity of this effect by showing that substitution R596H does not weaken the interaction between ς and two other regulators shown previously to contact region 4 of ς70. We also demonstrated that AlgQ, a homolog of Rsd that positively regulates virulence gene expression in Pseudomonas aeruginosa, can contact the C-terminal region of the ς70 subunit of RNAP from this organism. We found that amino acid substitution R600H in ς70 from P. aeruginosa, corresponding to the R596H substitution in E. coli ς70, specifically weakens the interaction between AlgQ and ς70. Taken together, our findings suggest that Rsd and AlgQ contact similar surfaces of RNAP present in region 4 of ς70 and probably regulate gene expression through this contact. PMID:11591686
Dove, S L; Hochschild, A
2001-11-01
A number of transcriptional regulators mediate their effects through direct contact with the sigma(70) subunit of Escherichia coli RNA polymerase (RNAP). In particular, several regulators have been shown to contact a C-terminal portion of sigma(70) that harbors conserved region 4. This region of sigma contains a putative helix-turn-helix DNA-binding motif that contacts the -35 element of sigma(70)-dependent promoters directly. Here we report the use of a recently developed bacterial two-hybrid system to study the interaction between the putative anti-sigma factor Rsd and the sigma(70) subunit of E. coli RNAP. Using this system, we found that Rsd can interact with an 86-amino-acid C-terminal fragment of sigma(70) and also that amino acid substitution R596H, within region 4 of sigma(70), weakens this interaction. We demonstrated the specificity of this effect by showing that substitution R596H does not weaken the interaction between sigma and two other regulators shown previously to contact region 4 of sigma(70). We also demonstrated that AlgQ, a homolog of Rsd that positively regulates virulence gene expression in Pseudomonas aeruginosa, can contact the C-terminal region of the sigma(70) subunit of RNAP from this organism. We found that amino acid substitution R600H in sigma(70) from P. aeruginosa, corresponding to the R596H substitution in E. coli sigma(70), specifically weakens the interaction between AlgQ and sigma(70). Taken together, our findings suggest that Rsd and AlgQ contact similar surfaces of RNAP present in region 4 of sigma(70) and probably regulate gene expression through this contact.
Impedance-controlled ultrasound probe
NASA Astrophysics Data System (ADS)
Gilbertson, Matthew W.; Anthony, Brian W.
2011-03-01
An actuated hand-held impedance-controlled ultrasound probe has been developed. The controller maintains a prescribed contact state (force and velocity) between the probe and a patient's body. The device will enhance the diagnostic capability of free-hand elastography and swept-force compound imaging, and also make it easier for a technician to acquire repeatable (i.e. directly comparable) images over time. The mechanical system consists of an ultrasound probe, ball-screw-driven linear actuator, and a force/torque sensor. The feedback controller commands the motor to rotate the ball-screw to translate the ultrasound probe in order to maintain a desired contact force. It was found that users of the device, with the control system engaged, maintain a constant contact force with 15 times less variation than without the controller engaged. The system was used to determine the elastic properties of soft tissue.
Steuwe, Carolin; Daniels, Judith K; Frewen, Paul A; Densmore, Maria; Theberge, Jean; Lanius, Ruth A
2015-05-30
In healthy individuals, direct eye contact is thought to modulate a cortical route eliciting social cognitive processes via activation of a fast subcortical pathway. This study aimed to examine functional brain connectivity during direct eye contact in women with posttraumatic stress disorder (PTSD) related to childhood abuse as compared with healthy controls. We conducted psychophysiological interaction (PPI) analyses in Statistical Parametric Mapping-8 (SPM8) using the superior colliculus (SC) and locus coeruleus (LC) as seed regions while 16 healthy subjects and 16 patients with a primary diagnosis of PTSD related to childhood maltreatment viewed a functional magnetic resonance imaging (fMRI) paradigm involving direct (D) versus averted (A) gaze (happy, sad, neutral). The PTSD group showed a significantly enhanced connectivity between the SC and the anterior cingulate, and between the LC and the thalamus, caudate, putamen, insula, cingulate gyrus, and amygdala, as compared with healthy individuals. Symptom severity scores on the Clinician-Administered PTSD Scale (CAPS) showed significant positive correlations with superior colliculus connectivity with the perigenual and posterior cingulate, insula, and sublenticular extended amygdala. Functional connectivity data suggest increased recruitment of brain regions involved in emotion processing during direct gaze in PTSD in association with the fast subcortical pathway. The interpretation of eye contact as a signal of threat may require more emotion regulatory capacities in patients with PTSD. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.
Code of Federal Regulations, 2011 CFR
2011-07-01
... conditioner. An exhaust conditioner that cools the exhaust gas without direct contact with water. Exhaust conditioner. An enclosure, containing a cooling system, through which the exhaust gases pass. Exhaust system... between which the escape of flame is prevented. Flammable mixture. A mixture of methane or natural gas...
Code of Federal Regulations, 2010 CFR
2010-07-01
... conditioner. An exhaust conditioner that cools the exhaust gas without direct contact with water. Exhaust conditioner. An enclosure, containing a cooling system, through which the exhaust gases pass. Exhaust system... between which the escape of flame is prevented. Flammable mixture. A mixture of methane or natural gas...
Code of Federal Regulations, 2013 CFR
2013-07-01
... between which the escape of flame is prevented. Flammable mixture. A mixture of methane or natural gas... conditioner. An exhaust conditioner that cools the exhaust gas without direct contact with water. Exhaust conditioner. An enclosure, containing a cooling system, through which the exhaust gases pass. Exhaust system...
The Mast Cell, Contact, and Coagulation System Connection in Anaphylaxis
Guilarte, Mar; Sala-Cunill, Anna; Luengo, Olga; Labrador-Horrillo, Moisés; Cardona, Victoria
2017-01-01
Anaphylaxis is the most severe form of allergic reaction, resulting from the effect of mediators and chemotactic substances released by activated cells. Mast cells and basophils are considered key players in IgE-mediated human anaphylaxis. Beyond IgE-mediated activation of mast cells/basophils, further mechanisms are involved in the occurrence of anaphylaxis. New insights into the potential relevance of pathways other than mast cell and basophil degranulation have been unraveled, such as the activation of the contact and the coagulation systems. Mast cell heparin released upon activation provides negatively charged surfaces for factor XII (FXII) binding and auto-activation. Activated FXII, the initiating serine protease in both the contact and the intrinsic coagulation system, activates factor XI and prekallikrein, respectively. FXII-mediated bradykinin (BK) formation has been proven in the human plasma of anaphylactic patients as well as in experimental models of anaphylaxis. Moreover, the severity of anaphylaxis is correlated with the increase in plasma heparin, BK formation and the intensity of contact system activation. FXII also activates plasminogen in the fibrinolysis system. Mast cell tryptase has been shown to participate in fibrinolysis through plasmin activation and by facilitating the degradation of fibrinogen. Some usual clinical manifestations in anaphylaxis, such as angioedema or hypotension, or other less common, such as metrorrhagia, may be explained by the direct effect of the activation of the coagulation and contact system driven by mast cell mediators. PMID:28798744
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-01
... holidays. For service information identified in this AD, contact AVStar Fuel Systems, Inc., 1365 Park Lane... a faulty fuel servo, Bendix model RSA-10ED1. AVStar Fuel Systems (AFS) had overhauled the fuel servo...) since new due to suspected manufacturing defects. AVStar Fuel Systems produces diaphragms, P/Ns...
Photo-stimulated low electron temperature high current diamond film field emission cathode
Shurter,; Roger Philips, Devlin [Los Alamos, NM; David James, Moody [Santa Fe, NM; Nathan Andrew, Taccetti [Los Alamos, NM; Jose Martin, Russell [Santa Fe, NM; John, Steven [Los Alamos, NM
2012-07-24
An electron source includes a back contact surface having a means for attaching a power source to the back contact surface. The electron source also includes a layer comprising platinum in direct contact with the back contact surface, a composite layer of single-walled carbon nanotubes embedded in platinum in direct contact with the layer comprising platinum. The electron source also includes a nanocrystalline diamond layer in direct contact with the composite layer. The nanocrystalline diamond layer is doped with boron. A portion of the back contact surface is removed to reveal the underlying platinum. The electron source is contained in an evacuable container.
Oscillatory ductile compaction dynamics in a cylinder
NASA Astrophysics Data System (ADS)
Uri, Lina; Dysthe, Dag Kristian; Feder, Jens
2006-09-01
Ductile compaction is common in many natural systems, but the temporal evolution of such systems is rarely studied. We observe surprising oscillations in the weight measured at the bottom of a self-compacting ensemble of ductile grains. The oscillations develop during the first ten hours of the experiment, and usually persist through the length of an experiment (one week). The weight oscillations are connected to the grain-wall contacts, and are directly correlated with the observed strain evolution and the dynamics of grain-wall contacts during the compaction. Here, we present the experimental results and characteristic time constants of the system, and discuss possible reasons for the measured weight oscillations.
Oscillatory ductile compaction dynamics in a cylinder.
Uri, Lina; Dysthe, Dag Kristian; Feder, Jens
2006-09-01
Ductile compaction is common in many natural systems, but the temporal evolution of such systems is rarely studied. We observe surprising oscillations in the weight measured at the bottom of a self-compacting ensemble of ductile grains. The oscillations develop during the first ten hours of the experiment, and usually persist through the length of an experiment (one week). The weight oscillations are connected to the grain-wall contacts, and are directly correlated with the observed strain evolution and the dynamics of grain-wall contacts during the compaction. Here, we present the experimental results and characteristic time constants of the system, and discuss possible reasons for the measured weight oscillations.
78 FR 23691 - Airworthiness Directives; the Boeing Company
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-22
... off electrical power to the in-flight entertainment (IFE) systems and other non-essential electrical...., Washington, DC 20590. FOR FURTHER INFORMATION CONTACT: Ray Mei, Aerospace Engineer, Systems and Equipment... circuit breaker, relays, and wiring to allow the flightcrew to turn off electrical power to the IFE...
Vokes, David E.; Jackson, Ryan; Guo, Shuguang; Perez, Jorge A.; Su, Jianping; Ridgway, James M.; Armstrong, William B.; Chen, Zhongping; Wong, Brian J. F.
2014-01-01
Objectives Optical coherence tomography (OCT) is a new imaging modality that uses near-infrared light to produce cross-sectional images of tissue with a resolution approaching that of light microscopy. We have previously reported use of OCT imaging of the vocal folds (VFs) during direct laryngoscopy with a probe held in contact or near-contact with the VFs. This aim of this study was to develop and evaluate a novel OCT system integrated with a surgical microscope to allow hands-free OCT imaging of the VFs, which could be performed simultaneously with microscopic visualization. Methods We performed a prospective evaluation of a new method of acquiring OCT images of the VFs. Results An OCT system was successfully integrated with a surgical microscope to permit noncontact OCT imaging of the VFs of 10 patients. With this novel device we were able to identify VF epithelium and lamina propria; however, the resolution was reduced compared to that achieved with the standard contact or near-contact OCT. Conclusions Optical coherence tomography is able to produce high-resolution images of vocal fold mucosa to a maximum depth of 1.6 mm. It may be used in the diagnosis of VF lesions, particularly early squamous cell carcinoma, in which OCT can show disruption of the basement membrane. Mounting the OCT device directly onto the operating microscope allows hands-free noncontact OCT imaging and simultaneous conventional microscopic visualization of the VFs. However, the lateral resolution of the OCT microscope system is 50 µm, in contrast to the conventional handheld probe system (10 µm). Although such images at this resolution are still useful clinically, improved resolution would enhance the system’s performance, potentially enabling real-time OCT-guided microsurgery of the larynx. PMID:18700431
A novel algorithm for determining contact area between a respirator and a headform.
Lei, Zhipeng; Yang, James; Zhuang, Ziqing
2014-01-01
The contact area, as well as the contact pressure, is created when a respiratory protection device (a respirator or surgical mask) contacts a human face. A computer-based algorithm for determining the contact area between a headform and N95 filtering facepiece respirator (FFR) was proposed. Six N95 FFRs were applied to five sizes of standard headforms (large, medium, small, long/narrow, and short/wide) to simulate respirator donning. After the contact simulation between a headform and an N95 FFR was conducted, a contact area was determined by extracting the intersection surfaces of the headform and the N95 FFR. Using computer-aided design tools, a superimposed contact area and an average contact area, which are non-uniform rational basis spline (NURBS) surfaces, were developed for each headform. Experiments that directly measured dimensions of the contact areas between headform prototypes and N95 FFRs were used to validate the simulation results. Headform sizes influenced all contact area dimensions (P < 0.0001), and N95 FFR sizing systems influenced all contact area dimensions (P < 0.05) except the left and right chin regions. The medium headform produced the largest contact area, while the large and small headforms produced the smallest.
Williams, David M; Dechen Quinn, Amy C; Porter, William F
2014-01-01
Contacts between hosts are essential for transmission of many infectious agents. Understanding how contacts, and thus transmission rates, occur in space and time is critical to effectively responding to disease outbreaks in free-ranging animal populations. Contacts between animals in the wild are often difficult to observe or measure directly. Instead, one must infer contacts from metrics such as proximity in space and time. Our objective was to examine how contacts between white-tailed deer (Odocoileus virginianus) vary in space and among seasons. We used GPS movement data from 71 deer in central New York State to quantify potential direct contacts between deer and indirect overlap in space use across time and space. Daily probabilities of direct contact decreased from winter (0.05-0.14), to low levels post-parturition through summer (0.00-0.02), and increased during the rut to winter levels. The cumulative distribution for the spatial structure of direct and indirect contact probabilities around a hypothetical point of occurrence increased rapidly with distance for deer pairs separated by 1,000 m-7,000 m. Ninety-five percent of the probabilities of direct contact occurred among deer pairs within 8,500 m of one another, and 99% within 10,900 m. Probabilities of indirect contact accumulated across greater spatial extents: 95% at 11,900 m and 99% at 49,000 m. Contacts were spatially consistent across seasons, indicating that although contact rates differ seasonally, they occur proportionally across similar landscape extents. Distributions of contact probabilities across space can inform management decisions for assessing risk and allocating resources in response.
Hypothalamohypophysial vascular and neurosecretory link in the teleost Bagarius bagarius (Ham.).
Sathyanesan, A G; Jose, T M
1975-01-01
A three-dimensional picture of the hypothalamohypophysial neurosecretory system of B. bargarius could be obtained by adopting in situ staining techniques. The paired NPO give rise to left and right neurosecretory tracts which, although they approximate as a common tract, maintain their individuality till entering the pars intermedia. The ventral hypothalamic and the hypophysial arteries take their origin from the internal carotid artery. The former contributes to the formation of the primary plexus of the median eminence and the latter enters the pituitary directly, giving rise to the neuroadreno-interface vasculature. The vasculature of the median eminence lies in close contact with the long common neurosecretory tract. Morphological evidence suggests that in B. bagarius there are three pathways of hypothalamic control of the hypophysis: (1) A direct neuroglandular pathway, where the neurosecretory axons come directly in contact with the adrenohypophysial cells. (2) An indirect neurovasculoglandular pathway, where the blood exposed to the NSM at the median eminence comes in contact with gland cells. (3) Another indirect neurovasculoglandular pathway, where the blood is exposed to NSM at the neurohypophysis prior coming in contact with the gland cells. Thus, B. bagarius has the 'median eminence equivalent' neuroadeno-interface vasculature typical of the teleosts and the median eminence comparable to the Elasmobranchs, Holocephali and primitive Actinopterygians. This shows that the pituitary portal system of teleosts is in general agreement with that of other fish groups, except that in some it is restricted to the neuroadreno-interface, whereas in others like B. bagarius it extends to the hypothalamus also. These may be termed anterior and posterior median eminence.
Direct and extended intergenerational contact and young people's attitudes towards older adults.
Drury, Lisbeth; Hutchison, Paul; Abrams, Dominic
2016-09-01
Research suggests that positive intergenerational contact can improve young people's attitudes towards older adults. However, today's age-segregated society may not provide ample opportunities for positive contact between younger and older adults to occur on a regular basis. In three studies, we investigated whether the positive attitudinal outcomes associated with direct contact might also stem from a more indirect form of intergenerational relationship: extended contact. In Study 1 (N = 70), extended contact was associated with more positive attitudes towards older adults even when controlling for direct intergenerational contact (contact frequency and contact quality). In Study 2 (N = 110), the positive effects of direct and extended contact on young people's age-related attitudes were mediated by reductions in intergroup anxiety and ageing anxiety. The mediational effects of intergroup anxiety were replicated in Study 3 (N = 95) and ingroup norms additionally emerged as a mediator of the positive effects of extended contact on young people's attitudes towards older adults. Discussion focuses on the implications for strategies aimed at tackling ageism. ©2016 The Authors. British Journal of Social Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.
Laserthermia: a new computer-controlled contact Nd: YAG system for interstitial local hyperthermia.
Daikuzono, N; Suzuki, S; Tajiri, H; Tsunekawa, H; Ohyama, M; Joffe, S N
1988-01-01
Contact Nd:YAG laser surgery is assuming a greater importance in endoscopic and open surgery, allowing coagulation, cutting, and vaporization with greater precision and safety. A new contact probe allows a wider angle of irradiation and diffusion of low-power laser energy (less than 5 watts), using the interstitial technique for producing local hyperthermia. Temperature sensors that monitor continuously can be placed directly into the surrounding tissue or tumor. Using a computer program interfaced with the laser and sensors, a controlled and stable temperature (e.g., 42 degrees C) can be produced in a known volume of tissue over a prolonged period of time (e.g., 20-40 min). This new laserthermia system, using a single low-power Nd:YAG laser for interstitial local hyperthermia, may offer many new advantages in the experimental treatment and clinical management of carcinoma. A multiple system is now being developed.
Ko, Hyojin; Lee, Jeong Soo; Jung, Chan-Hee; Choi, Jae-Hak; Kwon, Oh-Sun; Shin, Kwanwoo
2014-08-01
Basic manipulations of discrete liquid drops on opened microfluidic chips based on electrowetting on dielectrics were described. While most developed microfluidic chips are closed systems equipped with a top plate to cover mechanically and to contact electrically to drop samples, our chips are opened systems with a single plate without any electric contact to drops directly. The chips consist of a linear array of patterned electrodes at 1.8 mm pitch was fabricated on a glass plate coated with thin hydrophobic and dielectric layers by using various methods including photolithography, spin coating and ion sputtering. Several actuations such as lateral oscillation, colliding mergence and translational motion for 3-10 μL water drops have been demonstrated satisfactory. All these kinetic performances of opened chips were similar to those of closed chip systems, indicating superiority of a none-contact method for the transport of drops on opened microfluidic chips actuated by using electrowetting technique.
Modular bioreactor for the remediation of liquid streams and methods for using the same
Noah, Karl S.; Sayer, Raymond L.; Thompson, David N.
1998-01-01
The present invention is directed to a bioreactor system for the remediation of contaminated liquid streams. The bioreactor system is composed of at least one and often a series of sub-units referred to as bioreactor modules. The modular nature of the system allows bioreactor systems be subdivided into smaller units and transported to waste sites where they are combined to form bioreactor systems of any size. The bioreactor modules further comprises reactor fill materials in the bioreactor module that remove the contaminants from the contaminated stream. To ensure that the stream thoroughly contacts the reactor fill materials, each bioreactor module comprises means for directing the flow of the stream in a vertical direction and means for directing the flow of the stream in a horizontal direction. In a preferred embodiment, the reactor fill comprises a sulfate reducing bacteria which is particularly useful for precipitating metals from acid mine streams.
Modular bioreactor for the remediation of liquid streams and methods for using the same
Noah, K.S.; Sayer, R.L.; Thompson, D.N.
1998-06-30
The present invention is directed to a bioreactor system for the remediation of contaminated liquid streams. The bioreactor system is composed of at least one and often a series of sub-units referred to as bioreactor modules. The modular nature of the system allows bioreactor systems be subdivided into smaller units and transported to waste sites where they are combined to form bioreactor systems of any size. The bioreactor modules further comprises reactor fill materials in the bioreactor module that remove the contaminants from the contaminated stream. To ensure that the stream thoroughly contacts the reactor fill materials, each bioreactor module comprises means for directing the flow of the stream in a vertical direction and means for directing the flow of the stream in a horizontal direction. In a preferred embodiment, the reactor fill comprises a sulfate reducing bacteria which is particularly useful for precipitating metals from acid mine streams. 6 figs.
37 CFR 10.33 - Direct contact with prospective clients.
Code of Federal Regulations, 2012 CFR
2012-07-01
... TRADEMARK OFFICE, DEPARTMENT OF COMMERCE REPRESENTATION OF OTHERS BEFORE THE PATENT AND TRADEMARK OFFICE Patent and Trademark Office Code of Professional Responsibility § 10.33 Direct contact with prospective... 37 Patents, Trademarks, and Copyrights 1 2012-07-01 2012-07-01 false Direct contact with...
Coupling of fingertip somatosensory information to head and body sway
NASA Technical Reports Server (NTRS)
Jeka, J. J.; Schoner, G.; Dijkstra, T.; Ribeiro, P.; Lackner, J. R.
1997-01-01
Light touch contact of a fingertip with a stationary surface can provide orientation information that enhances control of upright stance. Slight changes in contact force at the fingertip provide sensory cues about the direction of body sway, allowing attenuation of sway. In the present study, we asked to which extent somatosensory cues are part of the postural control system, that is, which sensory signal supports this coupling? We investigated postural control not only when the contact surface was stationary, but also when it was moving rhythmically (from 0.1 to 0.5 Hz). In doing so, we brought somatosensory cues from the hand into conflict with other parts of the postural control system. Our focus was the temporal relationship between body sway and the contact surface. Postural sway was highly coherent with contact surface motion. Head and body sway assumed the frequency of the moving contact surface at all test frequencies. To account for these results, a simple model was formulated by approximating the postural control system as a second-order linear dynamical system. The influence of the touch stimulus was captured as the difference between the velocity of the contact surface and the velocity of body sway, multiplied by a coupling constant. Comparison of empirical results (relative phase, coherence, and gain) with model predictions supports the hypothesis of coupling between body sway and touch cues through the velocity of the somatosensory stimulus at the fingertip. One subject, who perceived movement of the touch surface, demonstrated weaker coupling than other subjects, suggesting that cognitive mechanisms introduce flexibility into the postural control scheme.
Williams, David M.; Dechen Quinn, Amy C.; Porter, William F.
2014-01-01
Contacts between hosts are essential for transmission of many infectious agents. Understanding how contacts, and thus transmission rates, occur in space and time is critical to effectively responding to disease outbreaks in free-ranging animal populations. Contacts between animals in the wild are often difficult to observe or measure directly. Instead, one must infer contacts from metrics such as proximity in space and time. Our objective was to examine how contacts between white-tailed deer (Odocoileus virginianus) vary in space and among seasons. We used GPS movement data from 71 deer in central New York State to quantify potential direct contacts between deer and indirect overlap in space use across time and space. Daily probabilities of direct contact decreased from winter (0.05–0.14), to low levels post-parturition through summer (0.00–0.02), and increased during the rut to winter levels. The cumulative distribution for the spatial structure of direct and indirect contact probabilities around a hypothetical point of occurrence increased rapidly with distance for deer pairs separated by 1,000 m – 7,000 m. Ninety-five percent of the probabilities of direct contact occurred among deer pairs within 8,500 m of one another, and 99% within 10,900 m. Probabilities of indirect contact accumulated across greater spatial extents: 95% at 11,900 m and 99% at 49,000 m. Contacts were spatially consistent across seasons, indicating that although contact rates differ seasonally, they occur proportionally across similar landscape extents. Distributions of contact probabilities across space can inform management decisions for assessing risk and allocating resources in response. PMID:24409293
Materese, Christopher Kroboth; Goldmon, Christa Charisse; Papoian, Garegin A
2008-08-05
The native state dynamics of the small globular serine protease inhibitor eglin c has been studied in a long 336 ns computer simulation in explicit solvent. We have elucidated the energy landscape explored during the course of the simulation by using Principal Component Analysis. We observe several basins in the energy landscape in which the system lingers for extended periods. Through an iterative process we have generated a tree-like hierarchy of states describing the observed dynamics. We observe a range of divergent contact types including salt bridges, hydrogen bonds, hydrophilic interactions, and hydrophobic interactions, pointing to the frustration between competing interactions. Additionally, we find evidence of competing water-mediated interactions. Divergence in water-mediated interactions may be found to supplement existing direct contacts, but they are also found to be independent of such changes. Water-mediated contacts facilitate interactions between residues of like charge as observed in the simulation. Our results provide insight into the complexity of the dynamic native state of a globular protein and directly probe the residual frustration in the native state.
Disproportionate Minority Contact.
Fix, Rebecca L; Cyperski, Melissa A; Burkhart, Barry R
2017-04-01
The overrepresentation of racial/ethnic minorities within the criminal justice system relative to their population percentage, a phenomenon termed disproportionate minority contact, has been examined within general adult and adolescent offender populations; yet few studies have tested whether this phenomenon extends to juvenile sexual offenders (JSOs). In addition, few studies have examined whether offender race/ethnicity influences registration and notification requirements, which JSOs are subject to in some U.S. states. The present study assessed for disproportionate minority contact among general delinquent offenders and JSOs, meaning it aimed to test whether the criminal justice system treats those accused of sexual and non-sexual offenses differently by racial/ethnic group. Furthermore, racial/ethnic group differences in risk, legal classification, and sexual offending were examined for JSOs. Results indicated disproportionate minority contact was present among juveniles with non-sexual offenses and JSOs in Alabama. In addition, offense category and risk scores differed between African American and European American JSOs. Finally, registration classifications were predicted by offending characteristics, but not race/ethnicity. Implications and future directions regarding disproportionate minority contact among JSOs and social and legal policy affecting JSOs are discussed.
Rabban, J; Adler, J; Rosen, C; Blair, J; Sheridan, R
1997-09-01
Railway and subway-associated electrical trauma is rare and typically involves high voltage (> 20,000) arc injuries. Not all rail systems utilize such high voltage. We report 16 cases of electrical trauma due to 600 V direct contact with subway 'third' rails. A case series of injured patients presenting to Shriners Burns Institute, Boston or Massachusetts General Hospital between 1970 and 1995 was retrospectively analyzed. A total of 16 cases was identified. Among seven subway workers, the mechanism of rail contact was unintentional by a tool, a hand or by falling; no deaths occurred. Among nine non-occupational victims, injuries involved suicide attempts, unintentional falls, or risk-taking behavior. This group suffered greater burn severity, operative procedures, and complications; three deaths occurred. This is the largest report series of direct electrical trauma from a subway third rail. The high morbidity and mortality from this 600 V contact suggests that the traditional classification of low voltage (< 1000 V) exposure can be subdivided to reflect the serious and lethal potential of intermediate range exposures compared to household range exposures (0-220 V).
Miniaturized, on-head, invasive electrode connector integrated EEG data acquisition system.
Ives, John R; Mirsattari, Seyed M; Jones, D
2007-07-01
Intracranial electroencephalogram (EEG) monitoring involves recording multi-contact electrodes. The current systems require separate wires from each recording contact to the data acquisition unit resulting in many connectors and cables. To overcome limitations of such systems such as noise, restrictions in patient mobility and compliance, we developed a miniaturized EEG monitoring system with the amplifiers and multiplexers integrated into the electrode connectors and mounted on the head. Small, surface-mounted instrumentation amplifiers, coupled with 8:1 analog multiplexers, were assembled into 8-channel modular units to connect to 16:1 analog multiplexer manifold to create a small (55 cm(3)) head-mounted 128-channel system. A 6-conductor, 30 m long cable was used to transmit the EEG signals from the patient to the remote data acquisition system. Miniaturized EEG amplifiers and analog multiplexers were integrated directly into the electrode connectors. Up to 128-channels of EEG were amplified and analog multiplexed directly on the patient's head. The amplified EEG data were obtained over one long wire. A miniaturized system of invasive EEG recording has the potential to reduce artefact, simplify trouble-shooting, lower nursing care and increase patient compliance. Miniaturization technology improves intracranial EEG monitoring and leads to >128-channel capacity.
Rilo, B; Fernández-Formoso, N; Mora, M J; Cadarso-Suárez, C; Santana, U
2009-08-01
This study was designed to characterize the distance of the contact glide in the closing masticatory stroke in healthy adult subjects, during chewing of three types of food (crustless bread, chewing gum and peanuts). Mandibular movements (masticatory movements and laterality movements with dental contact) were registered using a gnathograph (MK-6I Diagnostic System) on the right and left side during unilateral chewing of the three food types. Length of dental contact was measured in masticatory cycle, which is defined as where the terminal part of the chewing cycles could be superimposed on the pathways taken by the mandible during lateral excursions with occlusal contacts. The length of dental contact during mastication of chewing gum is 1.46 +/- 1 mm, during chewing of soft bread is 1.38 +/- 0.7 mm and during chewing of peanuts is 1.45 +/- 0.9 mm. There is no significant difference in the lengths of dental contact during mastication of three types of foods that enable direct tooth gliding.
English, Krista M; Langley, Joanne M; McGeer, Allison; Hupert, Nathaniel; Tellier, Raymond; Henry, Bonnie; Halperin, Scott A; Johnston, Lynn; Pourbohloul, Babak
2018-04-17
Nosocomial, or healthcare-associated infections (HAI), exact a high medical and financial toll on patients, healthcare workers, caretakers, and the health system. Interpersonal contact patterns play a large role in infectious disease spread, but little is known about the relationship between health care workers' (HCW) movements and contact patterns within a heath care facility and HAI. Quantitatively capturing these patterns will aid in understanding the dynamics of HAI and may lead to more targeted and effective control strategies in the hospital setting. Staff at 3 urban university-based tertiary care hospitals in Canada completed a detailed questionnaire on demographics, interpersonal contacts, in-hospital movement, and infection prevention and control practices. Staff were divided into categories of administrative/support, nurses, physicians, and "Other HCWs" - a fourth distinct category, which excludes physicians and nurses. Using quantitative network modeling tools, we constructed the resulting HCW "co-location network" to illustrate contacts among different occupations and with locations in hospital settings. Among 3048 respondents (response rate 38%) an average of 3.79, 3.69 and 3.88 floors were visited by each HCW each week in the 3 hospitals, with a standard deviation of 2.63, 1.74 and 2.08, respectively. Physicians reported the highest rate of direct patient contacts (> 20 patients/day) but the lowest rate of contacts with other HCWs; nurses had the most extended (> 20 min) periods of direct patient contact. "Other HCWs" had the most direct daily contact with all other HCWs. Physicians also reported significantly more locations visited per week than nurses, other HCW, or administrators; nurses visited the fewest. Public spaces such as the cafeteria had the most staff visits per week, but the least mean hours spent per visit. Inpatient settings had significantly more HCW interactions per week than outpatient settings. HCW contact patterns and spatial movement demonstrate significant heterogeneity by occupation. Control strategies that address this diversity among health care workers may be more effective than "one-strategy-fits-all" HAI prevention and control programs.
NASA Astrophysics Data System (ADS)
Ohmori, Shuichi; Narabayashi, Tadashi; Mori, Michitsugu
A steam injector (SI) is a simple, compact and passive pump and also acts as a high-performance direct-contact compact heater. This provides SI with capability to serve also as a direct-contact feed-water heater that heats up feed-water by using extracted steam from turbine. Our technology development aims to significantly simplify equipment and reduce physical quantities by applying "high-efficiency SI", which are applicable to a wide range of operation regimes beyond the performance and applicable range of existing SIs and enables unprecedented multistage and parallel operation, to the low-pressure feed-water heaters and emergency core cooling system of nuclear power plants, as well as achieve high inherent safety to prevent severe accidents by keeping the core covered with water (a severe accident-free concept). This paper describes the results of the scale model test, and the transient analysis of SI-driven passive core injection system (PCIS).
Direct observation of ballistic Andreev reflection
NASA Astrophysics Data System (ADS)
Klapwijk, T. M.; Ryabchun, S. A.
2014-12-01
An overview is presented of experiments on ballistic electrical transport in inhomogeneous superconducting systems which are controlled by the process of Andreev reflection. The initial experiments based on the coexistence of a normal phase and a superconducting phase in the intermediate state led to the concept itself. It was followed by a focus on geometrically inhomogeneous systems like point contacts, which provided a very clear manifestation of the energy and direction dependence of the Andreev reflection process. The point contacts have recently evolved towards the atomic scale owing to the use of mechanical break-junctions, revealing a very detailed dependence of Andreev reflection on the macroscopic phase of the superconducting state. In present-day research, the superconducting in homogeneity is constructed by clean room technology and combines superconducting materials, for example, with low-dimensional materials and topological insulators. Alternatively, the superconductor is combined with nano-objects, such as graphene, carbon nanotubes, or semiconducting nanowires. Each of these "inhomogeneous systems" provides a very interesting range of properties, all rooted in some manifestation of Andreev reflection.
NASA Astrophysics Data System (ADS)
Cao, M.; Xiao, J.
2008-02-01
Bearing excitation is one of the most important mechanical sources for vibration and noise generation in machine systems of a broad range of industries. Although extensively investigated, accurately predicting the vibration/acoustic behavior of bearings remains a challenging task because of its complicated nonlinear behaviors. While some ground work has been laid out on single-row deep-grooved ball (DGB) bearing, comprehensive modeling effort on spherical roller bearing (SRB) has yet to be carried out. This is mainly due to the facts that SRB system carries one more extra degree of freedom (DOF) on the moving race (could be either inner or outer race) and in general has more rolling elements compared with DGB. In this study, a comprehensive SRB excitation source model is developed. In addition to the vertical and horizontal displacements considered in previous investigations, the impacts of axial displacement/load are addressed by introducing the DOF in the axial shaft direction. Hence, instead of being treated as pre-assumed constants, the roller-inner/outer race contact angles are formulated as functions of the axial displacement of the moving race to reflect their dependence on the axial movement. The approach presented in this paper accounts for the point contacts between rollers and inner/outer races, as well as line contacts when the loads on individual rollers exceed the limit for point contact. A detailed contact-damping model reflecting the influences of the surface profiles and the speeds of the both contacting elements is developed and applied in the SRB model. Waviness of all the contact surfaces (including inner race, outer race, and rollers) is included and compared in this analysis. Extensive case studies are carried out to reveal the impacts of surface waviness, radial clearance, surface defects, and loading conditions on the force and displacement responses of the SRB system. System design guidelines are recommended based on the simulation results. This model is also applicable for bearing health monitoring, as demonstrated by the numerical case studies showing the frequency response of the system with moderate-to-large point defects on both inner and outer races, as well as the rollers. Comparisons between the simulation results and some conclusions reflecting common sense available in open literature serves as first hand partial validation of the developed model. Future validation efforts and further improvement directions are also provided. The comprehensive model developed in this investigation is a useful tool for machine system design, optimization, and performance evaluation.
Wearable knee health rehabilitation assessment using acoustical emissions
NASA Astrophysics Data System (ADS)
Teague, Caitlin N.; Hersek, Sinan; Conant, Jordan L.; Gilliland, Scott M.; Inan, Omer T.
2017-02-01
We have developed a novel, wearable sensing system based on miniature piezoelectric contact microphones for measuring the acoustical emissions from the knee during movement. The system consists of two contact microphones, positioned on the medial and lateral sides of the patella, connected to custom, analog pre-amplifier circuits and a microcontroller for digitization and data storage on a secure digital card. Tn addition to the acoustical sensing, the system includes two integrated inertial measurement sensors including accelerometer and gyroscope modalities to enable joint angle calculations; these sensors, with digital outputs, are connected directly to the same microcontroller. The system provides low noise, accurate joint acoustical emission and angle measurements in a wearable form factor and has several hours of battery life.
Decontamination of combustion gases in fluidized bed incinerators
Leon, Albert M.
1982-01-01
Sulfur-containing atmospheric pollutants are effectively removed from exit gas streams produced in a fluidized bed combustion system by providing a fluidized bed of particulate material, i.e. limestone and/or dolomite wherein a concentration gradient is maintained in the vertical direction. Countercurrent contacting between upwardly directed sulfur containing combustion gases and descending sorbent particulate material creates a concentration gradient across the vertical extent of the bed characterized in progressively decreasing concentration of sulfur, sulfur dioxide and like contaminants upwardly and decreasing concentration of e.g. calcium oxide, downwardly. In this manner, gases having progressively decreasing sulfur contents contact correspondingly atmospheres having progressively increasing concentrations of calcium oxide thus assuring optimum sulfur removal.
Study on portable optical 3D coordinate measuring system
NASA Astrophysics Data System (ADS)
Ren, Tongqun; Zhu, Jigui; Guo, Yinbiao
2009-05-01
A portable optical 3D coordinate measuring system based on digital Close Range Photogrammetry (CRP) technology and binocular stereo vision theory is researched. Three ultra-red LED with high stability is set on a hand-hold target to provide measuring feature and establish target coordinate system. Ray intersection based field directional calibrating is done for the intersectant binocular measurement system composed of two cameras by a reference ruler. The hand-hold target controlled by Bluetooth wireless communication is free moved to implement contact measurement. The position of ceramic contact ball is pre-calibrated accurately. The coordinates of target feature points are obtained by binocular stereo vision model from the stereo images pair taken by cameras. Combining radius compensation for contact ball and residual error correction, object point can be resolved by transfer of axes using target coordinate system as intermediary. This system is suitable for on-field large-scale measurement because of its excellent portability, high precision, wide measuring volume, great adaptability and satisfying automatization. It is tested that the measuring precision is near to +/-0.1mm/m.
Enhancement to Non-Contacting Stress Measurement of Blade Vibration Frequency
NASA Technical Reports Server (NTRS)
Platt, Michael; Jagodnik, John
2011-01-01
A system for turbo machinery blade vibration has been developed that combines time-of-arrival sensors for blade vibration amplitude measurement and radar sensors for vibration frequency and mode identification. The enabling technology for this continuous blade monitoring system is the radar sensor, which provides a continuous time series of blade displacement over a portion of a revolution. This allows the data reduction algorithms to directly calculate the blade vibration frequency and to correctly identify the active modes of vibration. The work in this project represents a significant enhancement in the mode identification and stress calculation accuracy in non-contacting stress measurement system (NSMS) technology when compared to time-of-arrival measurements alone.
Comparison of self-reported and observed water contact in an S. mansoni endemic village in Brazil.
Friedman, J F; Kurtis, J D; McGarvey, S T; Fraga, A L; Silveira, A; Pizziolo, V; Gazzinelli, G; LoVerde, P; Corrêa-Oliveira, R
2001-03-30
Estimates of exposure are critical for immuno-epidemiologic and intervention studies in human schistosomiasis. Direct observation of human water contact patterns is both costly and time consuming. To address these issues, we determined whether individuals residing in a Schistosoma mansoni endemic village in Brazil could accurately self-report their water contact patterns. We compared the results of a water contact questionnaire to the present gold standard, direct observation of water contact in 86 volunteers, aged 8--29. We administered a survey to estimate volunteers' frequency and type of water contact and directly measured each volunteers' water contact patterns during 5 weeks of detailed water contact observations. We found a poor correlation between self reported frequency of contact and directly observed exposure (rho=0.119, P=NS). The questionnaire data was supplemented by information about average body surface area of exposure and duration of contact for specific activities derived from observations of this cohort. This 'supplemented questionnaire' data was significantly correlated with their exposure index (rho=0.227, P=0.05). It provides a starting point from which questionnaires may develop to provide a more cost-effective and less labor intensive method of assessing water contact exposure at the level of the individual.
Method and system of measuring ultrasonic signals in the plane of a moving web
Hall, Maclin S.; Jackson, Theodore G.; Wink, Wilmer A.; Knerr, Christopher
1996-01-01
An improved system for measuring the velocity of ultrasonic signals within the plane of moving web-like materials, such as paper, paperboard and the like. In addition to velocity measurements of ultrasonic signals in the plane of the web in the machine direction, MD, and a cross direction, CD, generally perpendicular to the direction of the traveling web, therefor, one embodiment of the system in accordance with the present invention is also adapted to provide on-line indication of the polar specific stiffness of the moving web. In another embodiment of the invention, the velocity of ultrasonic signals in the plane of the web are measured by way of a plurality of ultrasonic transducers carried by synchronously driven wheels or cylinders, thus eliminating undue transducer wear due to any speed differences between the transducers and the web. In order to provide relatively constant contact force between the transducers and the webs, the transducers are mounted in a sensor housings which include a spring for biasing the transducer radially outwardly. The sensor housings are adapted to be easily and conveniently mounted to the carrier to provide a relatively constant contact force between the transducers and the moving web.
Method and system of measuring ultrasonic signals in the plane of a moving web
Hall, M.S.; Jackson, T.G.; Wink, W.A.; Knerr, C.
1996-02-27
An improved system for measuring the velocity of ultrasonic signals within the plane of moving web-like materials, such as paper, paperboard and the like is disclosed. In addition to velocity measurements of ultrasonic signals in the plane of the web in the machine direction, MD, and a cross direction, CD, generally perpendicular to the direction of the traveling web, therefore, one embodiment of the system in accordance with the present invention is also adapted to provide on-line indication of the polar specific stiffness of the moving web. In another embodiment of the invention, the velocity of ultrasonic signals in the plane of the web are measured by way of a plurality of ultrasonic transducers carried by synchronously driven wheels or cylinders, thus eliminating undue transducer wear due to any speed differences between the transducers and the web. In order to provide relatively constant contact force between the transducers and the webs, the transducers are mounted in a sensor housings which include a spring for biasing the transducer radially outwardly. The sensor housings are adapted to be easily and conveniently mounted to the carrier to provide a relatively constant contact force between the transducers and the moving web. 37 figs.
Application of an industrial robot to nuclear pharmacy
DOE Office of Scientific and Technical Information (OSTI.GOV)
Viola, J.
1994-12-31
Increased patient throughput and lengthened P.E.T. scan protocols have increased the radiation dose received by P.E.T. technologists. Automated methods of tracer infusion and blood sampling have been introduced to reduce direct contact with the radioisotopes, but significant radiation exposure still exists during the receipt and dispensing of the patient dose. To address this situation the authors have developed an automated robotic system which performs these tasks, thus limiting the physical contact between operator and radioisotope.
Douglas-fir container stock grown with fertilizer-amended media: Some preliminary results
Diane L. Haase; John Trobaugh; Robin Rose
2002-01-01
Incorporating fertilizer directly into the container growing media is a very new practice. Previously, it was believed that such a practice would result in toxicity due to direct contact with the root system and/or over fertilization. However, with the improved technology for controlled-release fertilizer, there is renewed interest in this practice. The objective of...
Structure of a bacterial type III secretion system in contact with a host membrane in situ
NASA Astrophysics Data System (ADS)
Nans, Andrea; Kudryashev, Mikhail; Saibil, Helen R.; Hayward, Richard D.
2015-12-01
Many bacterial pathogens of animals and plants use a conserved type III secretion system (T3SS) to inject virulence effector proteins directly into eukaryotic cells to subvert host functions. Contact with host membranes is critical for T3SS activation, yet little is known about T3SS architecture in this state or the conformational changes that drive effector translocation. Here we use cryo-electron tomography and sub-tomogram averaging to derive the intact structure of the primordial Chlamydia trachomatis T3SS in the presence and absence of host membrane contact. Comparison of the averaged structures demonstrates a marked compaction of the basal body (4 nm) occurs when the needle tip contacts the host cell membrane. This compaction is coupled to a stabilization of the cytosolic sorting platform-ATPase. Our findings reveal the first structure of a bacterial T3SS from a major human pathogen engaged with a eukaryotic host, and reveal striking `pump-action' conformational changes that underpin effector injection.
Structure of a bacterial type III secretion system in contact with a host membrane in situ.
Nans, Andrea; Kudryashev, Mikhail; Saibil, Helen R; Hayward, Richard D
2015-12-11
Many bacterial pathogens of animals and plants use a conserved type III secretion system (T3SS) to inject virulence effector proteins directly into eukaryotic cells to subvert host functions. Contact with host membranes is critical for T3SS activation, yet little is known about T3SS architecture in this state or the conformational changes that drive effector translocation. Here we use cryo-electron tomography and sub-tomogram averaging to derive the intact structure of the primordial Chlamydia trachomatis T3SS in the presence and absence of host membrane contact. Comparison of the averaged structures demonstrates a marked compaction of the basal body (4 nm) occurs when the needle tip contacts the host cell membrane. This compaction is coupled to a stabilization of the cytosolic sorting platform-ATPase. Our findings reveal the first structure of a bacterial T3SS from a major human pathogen engaged with a eukaryotic host, and reveal striking 'pump-action' conformational changes that underpin effector injection.
A Novel Algorithm for Determining Contact Area Between a Respirator and a Headform
Lei, Zhipeng; Yang, James; Zhuang, Ziqing
2016-01-01
The contact area, as well as the contact pressure, is created when a respiratory protection device (a respirator or surgical mask) contacts a human face. A computer-based algorithm for determining the contact area between a headform and N95 filtering facepiece respirator (FFR) was proposed. Six N95 FFRs were applied to five sizes of standard headforms (large, medium, small, long/narrow, and short/wide) to simulate respirator donning. After the contact simulation between a headform and an N95 FFR was conducted, a contact area was determined by extracting the intersection surfaces of the headform and the N95 FFR. Using computer-aided design tools, a superimposed contact area and an average contact area, which are non-uniform rational basis spline (NURBS) surfaces, were developed for each headform. Experiments that directly measured dimensions of the contact areas between headform prototypes and N95 FFRs were used to validate the simulation results. Headform sizes influenced all contact area dimensions (P < 0.0001), and N95 FFR sizing systems influenced all contact area dimensions (P < 0.05) except the left and right chin regions. The medium headform produced the largest contact area, while the large and small headforms produced the smallest. PMID:24579752
Reach Out and Touch Someone: West Alabama Designs a New Emergency Link.
ERIC Educational Resources Information Center
Coogan, Mercy Hardie
1980-01-01
Quality on-the-scene emergency care for a rural area is provided by West Alabama's Emergency Medical Services. The success of this delivery system is attributed to a radio/telephone communications system that provides quick, direct contact between paramedics at the scene and medical doctors miles away. (DS)
Large Deformation and Adhesive Contact Studies of Axisymmetric Membranes
Laprade, Evan J.; Long, Rong; Pham, Jonathan; Lawrence, Jimmy; Emrick, Todd; Crosby, Alfred; Hui, Chung-Yuen; Shull, Kenneth R.
2013-01-01
A model membrane contact system consisting of an acrylic copolymer membrane and polydimethyl-siloxane substrate was utilized to evaluate a recently developed nonlinear large-deformation adhesive contact analysis. Direct measurements of the local membrane apex strain during non-contact inflation indicated that the neo-Hookean model provides an accurate measure of membrane strain and supports its use as the strain energy function for the analysis. A time dependent modulus emerges from the analysis, with principal tensions obtained from a comparison of predicted and experimental membrane profiles. A displacement controlled geometry was more easily modeled than the pressure controlled geometry, the applicability of the analysis was limited by wrinkling instabilities. The substantial viscoelastic behavior of these membranes made it difficult to describe the entire membrane with a single modulus, given the nonuniform deformation history of the membranes. Given the difficulty in determining membrane tension from the measured pressure and profile fits using the model, the peel energy was used as a simpler measure of adhesion. Using an analytical balance in the displacement controlled geometry, the membrane tension at the contact line was directly measured. Coupled with contact angle imaging, the peel energy was determined. For the model membranes studied, this peel energy described the membrane/substrate adhesive interactions quite well, giving well-defined peel energies that were independent of the detailed strain state of the membrane. PMID:23289644
76 FR 14797 - Airworthiness Directives; Rolls-Royce plc (RR) RB211-Trent 900 Series Turbofan Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2011-03-18
.... Relevant Service Information Rolls-Royce plc has issued Trent 900 Series Propulsion Systems Alert Service... incorporating software 10.6 can be found in Rolls-Royce plc Trent 900 Series Propulsion Systems Alert Service... Propulsion Systems Alert SB No. RB.211-73-AG639, dated December 3, 2010, for related information. (i) Contact...
Paseiro-Cerrato, Rafael; Rodríguez-Bernaldo de Quirós, Ana; Otero-Pazos, Pablo; Sendón, Raquel; Paseiro-Losada, Perfecto
2018-03-01
The aim of the present study was to determine the migration kinetics of one photoinitiator, benzophenone, and two optical brighteners, Uvitex OB and 1,4-diphenyl-1,3-butadiene (DPBD), from low-density polyethylene (LDPE) films into cake. Transfer was assessed by both direct contact and also the vapour phase. To perform the migration tests by direct contact, plastic films enriched with the additives were placed between two cake slices. To evaluate the migration through the gas phase, cake and the fortified LDPE film were placed with no direct contact in a glass container that was hermetically closed. Samples were stored at different time-temperature conditions. Target compounds were extracted from the films with ethanol (70°C, 24 h) and analysed by HPLC-DAD. Relevant parameters such as partition and diffusion coefficients between food and plastic film were calculated. The Arrhenius equation was applied to estimate the diffusion coefficient at any temperature. The data indicate that migration of benzophenone occurs in a significant extent into cake by both direct contact and through the gas phase (no direct contact). Conversely, very little migration occurred for Uvitex OB by direct contact and none through the gas phase. Results for benzophenone suggest that migration through the gas phase should be considered when evaluating migration from food packaging materials into food.
Process for the enhanced capture of heavy metal emissions
Biswas, Pratim; Wu, Chang-Yu
2001-01-01
This invention is directed to a process for forming a sorbent-metal complex. The process includes oxidizing a sorbent precursor and contacting the sorbent precursor with a metallic species. The process further includes chemically reacting the sorbent precursor and the metallic species, thereby forming a sorbent-metal complex. In one particular aspect of the invention, at least a portion of the sorbent precursor is transformed into sorbent particles during the oxidation step. These sorbent particles then are contacted with the metallic species and chemically reacted with the metallic species, thereby forming a sorbent-metal complex. Another aspect of the invention is directed to a process for forming a sorbent metal complex in a combustion system. The process includes introducing a sorbent precursor into a combustion system and subjecting the sorbent precursor to an elevated temperature sufficient to oxidize the sorbent precursor and transform the sorbent precursor into sorbent particles. The process further includes contacting the sorbent particles with a metallic species and exposing the sorbent particles and the metallic species to a complex-forming temperature whereby the metallic species reacts with the sorbent particles thereby forming a sorbent-metal complex under UV irradiation.
Healthcare Industry Injuries by Patient Contact Status in Kentucky, 2012-2014.
Ranzenberger, Kristen; Bunn, Terry L; Slavova, Svetla
2016-10-01
The healthcare industry continues to have a high number of reported injuries. The purpose of this study was to characterize healthcare industry injuries by patient contact status, identify the occupations associated with healthcare injuries by patient contact status, and determine healthcare injury rates by occupation to gain a better understanding of healthcare industry-compensated injuries and better target safety practices and programs in the healthcare industry. Kentucky healthcare industry workers' compensation first reports of injuries from calendar years 2012-2014 were categorized into injuries involved in direct patient contact versus injuries without direct patient contact using narrative text analysis. Injury numbers and rates were calculated for a number of data variables. Healthcare injuries without direct patient contact (55% of all first reports of injuries) occurred more frequently among older workers (45 years old and older [51%]), in "other" occupations such as housekeeping and maintenance (28%), and as a result of falls/slips/trips (39%) and sprains/tears (38%). In contrast, a higher percentage of healthcare injuries involving direct patient contact occurred among workers younger than 35 years (48%), in healthcare support occupations (50%), and resulting from sprains/tears (66%) and lifting/handling (52%), compared with those without direct patient contact. Findings from this study can better target the need for new and/or additional specific workplace safety training, especially in the healthcare support and nursing occupations with and without patient contact.
Pelivanov, Ivan; Buma, Takashi; Xia, Jinjun; Wei, Chen-Wei; O'Donnell, Matthew
2014-01-01
Laser ultrasonic (LU) inspection represents an attractive, non-contact method to evaluate composite materials. Current non-contact systems, however, have relatively low sensitivity compared to contact piezoelectric detection. They are also difficult to adjust, very expensive, and strongly influenced by environmental noise. Here, we demonstrate that most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe scheme. In particular, a new type of a balanced fiber-optic Sagnac interferometer is presented as part of an all-optical LU pump-probe system for non-destructive testing and evaluation of aircraft composites. The performance of the LU system is demonstrated on a composite sample with known defects. Wide-band ultrasound probe signals are generated directly at the sample surface with a pulsed fiber laser delivering nanosecond laser pulses at a repetition rate up to 76 kHz rate with a pulse energy of 0.6 mJ. A balanced fiber-optic Sagnac interferometer is employed to detect pressure signals at the same point on the composite surface. A- and B-scans obtained with the Sagnac interferometer are compared to those made with a contact wide-band polyvinylidene fluoride transducer. PMID:24737921
Drewe, J A; O'Connor, H M; Weber, N; McDonald, R A; Delahay, R J
2013-07-01
Tuberculosis (TB) due to infection with Mycobacterium bovis is transmitted between cattle and badgers (Meles meles) in the UK and Ireland but it is unclear where or when transmission occurs. We investigated direct and indirect interactions between badgers and cattle using automated proximity loggers on animals and at badger latrines located on pasture, in an area of south-west England with a high-density badger population. Direct contacts (interactions within 1.4 m) between badgers and cattle at pasture were very rare (four out of >500000 recorded animal-to-animal contacts) despite ample opportunity for interactions to occur. Indirect interactions (visits to badger latrines by badgers and cattle) were two orders of magnitude more frequent than direct contacts: 400 visits by badgers and 1700 visits by cattle were recorded. This suggests that indirect contacts might be more important than direct contacts in terms of disease transmission at pasture. The TB infection status of individual badgers (ascribed with 93% accuracy using three diagnostic tests) did not affect the frequency or duration of their visits to latrines located on pasture grazed by cattle. Nevertheless, there was wide variation in contact behaviour between individuals, which highlights the importance of understanding heterogeneity in contact patterns when developing strategies to control disease spread in wildlife and livestock.
Powers, Christopher M; Chen, Yu-Jen; Scher, Irving; Lee, Thay Q
2006-01-01
The purpose of this study was to determine the influence of patellofemoral joint contact geometry on the modeling of three-dimensional patellofemoral joint forces. To achieve this goal, patellofemoral joint reaction forces (PFJRFs) that were measured from an in-vitro cadaveric set-up were compared to PFJRFs estimated from a computer model that did not consider patellofemoral joint contact geometry. Ten cadaver knees were used in this study. Each was mounted on a custom jig that was fixed to an Instron frame. Quadriceps muscle loads were accomplished using a pulley system and weights. The force in the patellar ligament was obtained using a buckle transducer. To quantify the magnitude and direction of the PFJRF, a six-axis load cell was incorporated into the femoral fixation system so that a rigid body assumption could be made. PFJRF data were obtained at 0 degrees , 20 degrees , 40 degrees and 60 degrees of knee flexion. Following in vitro testing, SIMM modeling software was used to develop computational models based on the three-dimensional coordinates (Microscribe digitizer) of individual muscle and patellar ligament force vectors obtained from the cadaver knees. The overall magnitude of the PFJRF estimated from the computer generated models closely matched the direct measurements from the in vitro set-up (Pearson's correlation coefficient, R(2)=0.91, p<0.001). Although the computational model accurately estimated the posteriorly directed forces acting on the joint, some discrepancies were noted in the forces acting in the superior and lateral directions. These differences however, were relatively small when expressed as a total of the overall PFJRF magnitude.
A strongly goal-directed close-range vision system for spacecraft docking
NASA Technical Reports Server (NTRS)
Boyer, Kim L.; Goddard, Ralph E.
1991-01-01
In this presentation, we will propose a strongly goal-oriented stereo vision system to establish proper docking approach motions for automated rendezvous and capture (AR&C). From an input sequence of stereo video image pairs, the system produces a current best estimate of: contact position; contact vector; contact velocity; and contact orientation. The processing demands imposed by this particular problem and its environment dictate a special case solution; such a system should necessarily be, in some sense, minimalist. By this we mean the system should construct a scene description just sufficiently rich to solve the problem at hand and should do no more processing than is absolutely necessary. In addition, the imaging resolution should be just sufficient. Extracting additional information and constructing higher level scene representations wastes energy and computational resources and injects an unnecessary degree of complexity, increasing the likelihood of malfunction. We therefore take a departure from most prior stereopsis work, including our own, and propose a system based on associative memory. The purpose of the memory is to immediately associate a set of motor commands with a set of input visual patterns in the two cameras. That is, rather than explicitly computing point correspondences and object positions in world coordinates and trying to reason forward from this information to a plan of action, we are trying to capture the essence of reflex behavior through the action of associative memory. The explicit construction of point correspondences and 3D scene descriptions, followed by online velocity and point of impact calculations, is prohibitively expensive from a computational point of view for the problem at hand. Learned patterns on the four image planes, left and right at two discrete but closely spaced instants in time, will be bused directly to infer the spacecraft reaction. This will be a continuing online process as the docking collar approaches.
Gentilli, Sergio; Morgandoa, Andrea; Velardocchia, Mauro; Pessione, Silvia; Pizzorno, Chiara
2007-01-01
The authors present their prototype of a system for electrical conduction in direct contact with laparoscopic tools, devised, designed and produced by them at the Politecnico di Torino Department of Mechanical Engineering. The system consists of a two-sided plate, one side being a non-conducting adhesive surface to stick to the surgical glove and the other a thin, flexible conductor shell. The authors used the instrument with surgical tools with metal handles during 4 laparoscopic procedures. Nowadays the method commonly used to electrify laparoscopic tools is by using a wire plugged to a fixed conducting point on the instrument. The prototype described here was devised and produced to avoid some of the awkwardness encountered during the numerous manoeuvres required to connect and disconnect the wire at the time of surgical intervention. This device permits the direct transfer (by contact) of electrical energy from the wire to surgical tools. The advantage is greater rapidity in changing surgical tools, with the possibility of immediately obtaining an electrified instrument in the surgeon's hand.
In the eye of the beholder: eye contact increases resistance to persuasion.
Chen, Frances S; Minson, Julia A; Schöne, Maren; Heinrichs, Markus
2013-11-01
Popular belief holds that eye contact increases the success of persuasive communication, and prior research suggests that speakers who direct their gaze more toward their listeners are perceived as more persuasive. In contrast, we demonstrate that more eye contact between the listener and speaker during persuasive communication predicts less attitude change in the direction advocated. In Study 1, participants freely watched videos of speakers expressing various views on controversial sociopolitical issues. Greater direct gaze at the speaker's eyes was associated with less attitude change in the direction advocated by the speaker. In Study 2, we instructed participants to look at either the eyes or the mouths of speakers presenting arguments counter to participants' own attitudes. Intentionally maintaining direct eye contact led to less persuasion than did gazing at the mouth. These findings suggest that efforts at increasing eye contact may be counterproductive across a variety of persuasion contexts.
Spontaneous Spreading of a Droplet: The Role of Solid Continuity and Advancing Contact Angle.
Jiang, Youhua; Sun, Yujin; Drelich, Jaroslaw W; Choi, Chang-Hwan
2018-05-01
Spontaneous spreading of a droplet on a solid surface is poorly understood from a macroscopic level down to a molecular level. Here, we investigate the effect of surface topography and wettability on spontaneous spreading of a water droplet. Spreading force is measured for a suspended droplet that minimizes interference of kinetic energy in the spontaneous spreading during its contact with solid surfaces of discontinuous (pillar) and continuous (pore) patterns with various shapes and dimensions. Results show that a droplet cannot spread spontaneously on pillared surfaces regardless of their shapes or dimensions because of the solid discontinuity. On the contrary, a droplet on pored surfaces can undergo spontaneous spreading whose force increases with a decrease in the advancing contact angle. Theoretical models based on both the system free energy and capillary force along the contact line validate the direct and universal dependency of the spontaneous spreading force on the advancing contact angle.
Viral contacts confound studies of childhood leukemia and high-voltage transmission lines.
Sahl, J D
1994-05-01
Studies of childhood leukemia have reported a link with residential proximity to electric utility facilities. This paper elaborates on the hypothesis that residential proximity to electric utility transmission-systems is a surrogate for viral contacts, a potential confounder in these studies. While the causal implications of increased viral contacts is not established, the assumption made here is that a significant component of childhood leukemia has an infectious etiology. Increased viral contacts can result from residential mobility, being first born, or use of community childcare facilities. Re-analysis of existing studies should look specifically for the interaction between childhood leukemia, markers for viral contacts (e.g., residential mobility, birth order, use of outside childcare facilities), and residential proximity to high-voltage transmission lines. New study designs should include parameters to test directly for a virus-related infectious model for childhood leukemia.
Ehrampoosh, Shervin; Dave, Mohit; Kia, Michael A; Rablau, Corneliu; Zadeh, Mehrdad H
2013-01-01
This paper presents an enhanced haptic-enabled master-slave teleoperation system which can be used to provide force feedback to surgeons in minimally invasive surgery (MIS). One of the research goals was to develop a combined-control architecture framework that included both direct force reflection (DFR) and position-error-based (PEB) control strategies. To achieve this goal, it was essential to measure accurately the direct contact forces between deformable bodies and a robotic tool tip. To measure the forces at a surgical tool tip and enhance the performance of the teleoperation system, an optical force sensor was designed, prototyped, and added to a robot manipulator. The enhanced teleoperation architecture was formulated by developing mathematical models for the optical force sensor, the extended slave robot manipulator, and the combined-control strategy. Human factor studies were also conducted to (a) examine experimentally the performance of the enhanced teleoperation system with the optical force sensor, and (b) study human haptic perception during the identification of remote object deformability. The first experiment was carried out to discriminate deformability of objects when human subjects were in direct contact with deformable objects by means of a laparoscopic tool. The control parameters were then tuned based on the results of this experiment using a gain-scheduling method. The second experiment was conducted to study the effectiveness of the force feedback provided through the enhanced teleoperation system. The results show that the force feedback increased the ability of subjects to correctly identify materials of different deformable types. In addition, the virtual force feedback provided by the teleoperation system comes close to the real force feedback experienced in direct MIS. The experimental results provide design guidelines for choosing and validating the control architecture and the optical force sensor.
Search Site submit About | Contacts | Directions Los Alamos National LaboratoryBradbury Science Museum Your Window into Los Alamos National Laboratory Bradbury Science Museum Menu About Contacts Directions Visit Visitor Information About the Museum Large Group Visits Around Los Alamos Contact Us
Contact resistance evolution of highly cycled, lightly loaded micro-contacts
NASA Astrophysics Data System (ADS)
Stilson, Christopher; Coutu, Ronald
2014-03-01
Reliable microelectromechanical systems (MEMS) switches are critical for developing high performance radio frequency circuits like phase shifters. Engineers have attempted to improve reliability and lifecycle performance using novel contact metals, unique mechanical designs and packaging. Various test fixtures including: MEMS devices, atomic force microscopes (AFM) and nanoindentors have been used to collect resistance and contact force data. AFM and nanoindentor test fixtures allow direct contact force measurements but are severely limited by low resonance sensors, and therefore low data collection rates. This paper reports the contact resistance evolution results and fabrication of thin film, sputtered and evaporated gold, micro-contacts dynamically tested up to 3kHz. The upper contact support structure consists of a gold surface micromachined, fix-fix beam designed with sufficient restoring force to overcome adhesion. The hemisphere-upper and planar-lower contacts are mated with a calibrated, external load resulting in approximately 100μN of contact force and are cycled in excess of 106 times or until failure. Contact resistance is measured, in-situ, using a cross-bar configuration and the entire apparatus is isolated from external vibration and housed in an enclosure to minimize contamination due to ambient environment. Additionally, contact cycling and data collection are automated using a computer and LabVIEW. Results include contact resistance measurements of 6 and 8 μm radius contact bumps and lifetime testing up to 323.6 million cycles.
Soenksen, L R; Kassis, T; Noh, M; Griffith, L G; Trumper, D L
2018-03-13
Precise fluid height sensing in open-channel microfluidics has long been a desirable feature for a wide range of applications. However, performing accurate measurements of the fluid level in small-scale reservoirs (<1 mL) has proven to be an elusive goal, especially if direct fluid-sensor contact needs to be avoided. In particular, gravity-driven systems used in several microfluidic applications to establish pressure gradients and impose flow remain open-loop and largely unmonitored due to these sensing limitations. Here we present an optimized self-shielded coplanar capacitive sensor design and automated control system to provide submillimeter fluid-height resolution (∼250 μm) and control of small-scale open reservoirs without the need for direct fluid contact. Results from testing and validation of our optimized sensor and system also suggest that accurate fluid height information can be used to robustly characterize, calibrate and dynamically control a range of microfluidic systems with complex pumping mechanisms, even in cell culture conditions. Capacitive sensing technology provides a scalable and cost-effective way to enable continuous monitoring and closed-loop feedback control of fluid volumes in small-scale gravity-dominated wells in a variety of microfluidic applications.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-10-07
... docket shortly after receipt. FOR FURTHER INFORMATION CONTACT: Robert Kaufman, Aerospace Engineer, Cabin.... Send information to Robert Kaufman, Aerospace Engineer, Cabin Safety and Environmental Systems Branch...
Method and apparatus for high-efficiency direct contact condensation
Bharathan, D.; Parent, Y.; Hassani, A.V.
1999-07-20
A direct contact condenser having a downward vapor flow chamber and an upward vapor flow chamber, wherein each of the vapor flow chambers includes a plurality of cooling liquid supplying pipes and a vapor-liquid contact medium disposed thereunder to facilitate contact and direct heat exchange between the vapor and cooling liquid. The contact medium includes a plurality of sheets arranged to form vertical interleaved channels or passageways for the vapor and cooling liquid streams. The upward vapor flow chamber also includes a second set of cooling liquid supplying pipes disposed beneath the vapor-liquid contact medium which operate intermittently in response to a pressure differential within the upward vapor flow chamber. The condenser further includes separate wells for collecting condensate and cooling liquid from each of the vapor flow chambers. In alternate embodiments, the condenser includes a cross-current flow chamber and an upward flow chamber, a plurality of upward flow chambers, or a single upward flow chamber. The method of use of the direct contact condenser of this invention includes passing a vapor stream sequentially through the downward and upward vapor flow chambers, where the vapor is condensed as a result of heat exchange with the cooling liquid in the contact medium. The concentration of noncondensable gases in the resulting condensate-liquid mixtures can be minimized by controlling the partial pressure of the vapor, which depends in part upon the geometry of the vapor-liquid contact medium. In another aspect of this invention, the physical and chemical performance of a direct contact condenser can be predicted based on the vapor and coolant compositions, the condensation conditions, and the geometric properties of the contact medium. 39 figs.
Method and apparatus for high-efficiency direct contact condensation
Bharathan, Desikan; Parent, Yves; Hassani, A. Vahab
1999-01-01
A direct contact condenser having a downward vapor flow chamber and an upward vapor flow chamber, wherein each of the vapor flow chambers includes a plurality of cooling liquid supplying pipes and a vapor-liquid contact medium disposed thereunder to facilitate contact and direct heat exchange between the vapor and cooling liquid. The contact medium includes a plurality of sheets arranged to form vertical interleaved channels or passageways for the vapor and cooling liquid streams. The upward vapor flow chamber also includes a second set of cooling liquid supplying pipes disposed beneath the vapor-liquid contact medium which operate intermittently in response to a pressure differential within the upward vapor flow chamber. The condenser further includes separate wells for collecting condensate and cooling liquid from each of the vapor flow chambers. In alternate embodiments, the condenser includes a cross-current flow chamber and an upward flow chamber, a plurality of upward flow chambers, or a single upward flow chamber. The method of use of the direct contact condenser of this invention includes passing a vapor stream sequentially through the downward and upward vapor flow chambers, where the vapor is condensed as a result of heat exchange with the cooling liquid in the contact medium. The concentration of noncondensable gases in the resulting condensate-liquid mixtures can be minimized by controlling the partial pressure of the vapor, which depends in part upon the geometry of the vapor-liquid contact medium. In another aspect of this invention, the physical and chemical performance of a direct contact condenser can be predicted based on the vapor and coolant compositions, the condensation conditions. and the geometric properties of the contact medium.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Jacobs, H.R.
1985-01-01
This report includes a project summary, copies of two papers resulting from the work and the Ph.D. Dissertation of Dr. Mehdi Golafshani entitled, ''Stability of a Direct Contact Heat Exchanger''. Specifically, the work deals with the operational stability of a spray column type heat exchanger subject to disturbances typical of those which can occur for geothermal applications. A computer program was developed to solve the one-dimensional transient two-phase flow problem and it was applied to the design of a spray column. The operation and design of the East Mesa 500kW/sub e/ direct contactor was assessed. It is shown that themore » heat transfer is governed by the internal resistance of the dispersed phase. In fact, the performance is well-represented by diffusion of heat within the drops. 5 refs.« less
Development of a wearable CMOS-based contact imaging system for real-time skin condition diagnosis
NASA Astrophysics Data System (ADS)
Petitdidier, Nils; Koenig, Anne; Gerbelot, Rémi; Gioux, Sylvain; Dinten, Jean-Marc
2017-07-01
Diffuse reflectance spectroscopy has been widely used in the field of biological tissue characterization with various modalities [1-5,6]. One of these modalities consists in measuring the spatially resolved diffuse reflectance (SRDR). In this technique, light is collected at multiple distances from the excitation point. The obtained reflectance decay curve is used to determine scattering and absorption properties of the tissue [7], which are directly related to tissue content and structure. Existing systems usually use fiber optics to collect light reflected from the tissue and transfer it to an optical sensor [1,6]. Such devices make it possible to perform SRDR measurements directly in contact with the tissue. However, they offer poor spatial sampling of the reflectance and low light collection efficiency. We propose to overcome these limitations by using a CMOS sensor placed in contact with the tissue to achieve light collection with high spatial sampling over several millimeters and with increased fill factor. Our objective in this paper is to demonstrate the potential of our instrument to determine the optical properties of tissues from SRDR measurements. We first describe the instrument and the employed methodology. Then, preliminary results obtained on optical phantoms are presented. Finally, the potential of our system for SRDR measurements is evaluated through comparison with a fiber-optic probe previously developed in our laboratory [6,8].
Search Site submit About | Contacts | Directions Los Alamos National LaboratoryBradbury Science Museum Your Window into Los Alamos National Laboratory Bradbury Science Museum Menu About Contacts Directions Visit Visitor Information About the Museum Large Group Visits Around Los Alamos Contact Us
Ling, Xue; Wang, Yusheng; Li, Xide
2014-10-01
An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects of the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li-Etsion-Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.
NASA Astrophysics Data System (ADS)
Ling, Xue; Wang, Yusheng; Li, Xide
2014-10-01
An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects of the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li-Etsion-Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.
Approaches of health caregivers to young children in a pediatric intensive care unit.
Orsuto, J; Corbo, B H
1987-01-01
This study explored the frequency of health caregiver approaches to 12 toddlers and preschool children in a pediatric intensive care unit. Using a time-sampling methodology, 3 hours of observation per child were obtained; half occurred between 7 A.M. and 7 P.M. and half were between 7 P.M. and 7 A.M.. Data were analyzed using descriptive statistics. Caregiver approaches involved either direct or indirect contact. Indirect contacts occurred three times more frequently than direct, with registered nurses initiating more contacts than any other caregivers. The greatest number of direct contacts were categorized as intrusive, while the least number were comforting contacts. The findings suggest that nurses are in optimal positions to promote rest and comforting contact for children in the pediatric intensive care unit.
Tactual interfaces: The human perceiver
NASA Technical Reports Server (NTRS)
Srinivasan, M. A.
1991-01-01
Increasingly complex human-machine interactions, such as in teleoperation or in virtual environments, have necessitated the optimal use of the human tactual channel for information transfer. This need leads to a demand for a basic understanding of how the human tactual system works, so that the tactual interface between the human and the machine can receive the command signals from the human, as well as display the information to the human, in a manner that appears natural to the human. The tactual information consists of two components: (1) contact information which specifies the nature of direct contact with the object; and (2) kinesthetic information which refers to the position and motion of the limbs. This paper is mostly concerned with contact information.
Dejong, Margaret; Davies, Hilary
2013-04-01
This paper aims to build on the existing literature, by presenting some thoughts based on clinical experience with nine families of children referred for intractable contact refusal with one parent following marital separation. This particular group of high-conflict divorce cases engenders an inordinate amount of frustration both within the courts and therapeutic agencies. We outline here our assessment process and therapeutic strategies, as well as consideration of the role of the wider professional system and the courts. We conclude that whether or not direct contact with the rejected parent is achieved, useful therapeutic work can be carried out to assist children in moving on with their lives.
Chojnacka, Magdalena; Gornicka, Agnieszka; Oeljeklaus, Silke; Warscheid, Bettina; Chacinska, Agnieszka
2015-06-12
The mitochondrial contact site and cristae organizing system (MICOS) is a recently discovered protein complex that is crucial for establishing and maintaining the proper inner membrane architecture and contacts with the outer membrane of mitochondria. The ways in which the MICOS complex is assembled and its integrity is regulated remain elusive. Here, we report a direct link between Cox17, a protein involved in the assembly of cytochrome c oxidase, and the MICOS complex. Cox17 interacts with Mic60, thereby modulating MICOS complex integrity. This interaction does not involve Sco1, a partner of Cox17 in transferring copper ions to cytochrome c oxidase. However, the Cox17-MICOS interaction is regulated by copper ions. We propose that Cox17 is a newly identified factor involved in maintaining the architecture of the MICOS complex. © 2015 by The American Society for Biochemistry and Molecular Biology, Inc.
From biofuels to predicting the flu
Search Site submit About | Contacts | Directions Los Alamos National LaboratoryBradbury Science Museum Your Window into Los Alamos National Laboratory Bradbury Science Museum Menu About Contacts Directions Visit Visitor Information About the Museum Large Group Visits Around Los Alamos Contact Us
Search Site submit About | Contacts | Directions Los Alamos National LaboratoryBradbury Science Museum Your Window into Los Alamos National Laboratory Bradbury Science Museum Menu About Contacts Directions Visit Visitor Information About the Museum Large Group Visits Around Los Alamos Contact Us
Electron transport in molecular wires with transition metal contacts
NASA Astrophysics Data System (ADS)
Dalgleish, Hugh
A molecular wire is an organic molecule that forms a conducting bridge between electronic contacts. Single molecules are likely to be the smallest entities to conduct electricity and thus molecular wires present many interesting challenges to fundamental science as well as enormous potential for nanoelectronic technological applications. A particular challenge stems from the realization that the properties of molecular wires are strongly influenced by the combined characteristics of the molecule and the metal contacts. While gold has been the most studied contact material to date, interest in molecular wires with transition metal contacts that are electronically more complex than gold is growing. This thesis presents a theoretical investigation of electron transport and associated phenomena in molecular wires with transition metal contacts. An appropriate methodology is developed on the basis of Landauer theory and ab initio and semi-empirical considerations and new, physically important systems are identified. Spin-dependent transport mechanisms and device characteristics are explored for molecular wires with ferromagnetic iron contacts, systems that have not been considered previously, either theoretically or experimentally. Electron transport between iron point contacts bridged by iron atoms is also investigated. Spin-dependent transport is also studied for molecules bridging nickel contacts and a possible explanation of some experimentally observed phenomena is proposed. A novel physical phenomenon termed strong spin current rectification and a new controllable negative differential resistance mechanism with potential applications for molecular electronic technology are introduced. The phenomena predicted in this thesis should be accessible to present day experimental techniques and this work is intended to stimulate experiments directed at observing them. Keywords. molecular electronics; spintronics; electron transport; interface states.
Heat reclaiming method and apparatus
Jardine, Douglas M.
1984-01-01
Method and apparatus to extract heat by transferring heat from hot compressed refrigerant to a coolant, such as water, without exceeding preselected temperatures in the coolant and avoiding boiling in a water system by removing the coolant from direct or indirect contact with the hot refrigerant.
Dean, Natalie E.; Halloran, M. Elizabeth; Yang, Yang; Longini, Ira M.
2016-01-01
Factors affecting our ability to control an Ebola outbreak include transmissibility of the virus and the proportion of transmissions occurring asymptomatically. We performed a meta-analysis of Ebola household secondary attack rate (SAR), disaggregating by type of exposure (direct contact, no direct contact, nursing care, direct contact but no nursing care). The estimated overall household SAR is 12.5% (95% confidence interval [CI], 8.6%–16.3%). Transmission was driven by direct contact, with little transmission occurring in its absence (SAR, 0.8% [95% CI, 0%–2.3%]). The greatest risk factor was the provision of nursing care (SAR, 47.9% [95% CI, 23.3%–72.6%]). There was evidence of a decline in household SAR for direct contact between 1976 and 2014 (P = .018). We estimate that 27.1% (95% CI, 14.5%–39.6%) of Ebola infections are asymptomatic. Our findings suggest that surveillance and containment measures should be effective for controlling Ebola. PMID:26932131
Micromechanics of Ultrafine Particle Adhesion—Contact Models
NASA Astrophysics Data System (ADS)
Tomas, Jürgen
2009-06-01
Ultrafine, dry, cohesive and compressible powders (particle diameter d<10 μm) show a wide variety of flow problems that cause insufficient apparatus and system reliability of processing plants. Thus, the understanding of the micromechanics of particle adhesion is essential to assess the product quality and to improve the process performance in particle technology. Comprehensive models are shown that describe the elastic-plastic force-displacement and frictional moment-angle behavior of adhesive contacts of isotropic smooth spheres. By the model stiff particles with soft contacts, a sphere-sphere interaction of van der Waals forces without any contact deformation describes the stiff attractive term. But, the soft micro-contact response generates a flattened contact, i.e. plate-plate interaction, and increasing adhesion. These increasing adhesion forces between particles directly depend on this frozen irreversible deformation. Thus, the adhesion force is found to be load dependent. It contributes to the tangential forces in an elastic-plastic frictional contact with partially sticking and micro-slip within the contact plane. The load dependent rolling resistance and torque of mobilized frictional contact rotation (spin around its principal axis) are also shown. This reasonable combination of particle contact micromechanics and powder continuum mechanics is used to model analytically the macroscopic friction limits of incipient powder consolidation, yield and cohesive steady-state shear flow on physical basis.
Limits to Forecasting Precision for Outbreaks of Directly Transmitted Diseases
Drake, John M
2006-01-01
Background Early warning systems for outbreaks of infectious diseases are an important application of the ecological theory of epidemics. A key variable predicted by early warning systems is the final outbreak size. However, for directly transmitted diseases, the stochastic contact process by which outbreaks develop entails fundamental limits to the precision with which the final size can be predicted. Methods and Findings I studied how the expected final outbreak size and the coefficient of variation in the final size of outbreaks scale with control effectiveness and the rate of infectious contacts in the simple stochastic epidemic. As examples, I parameterized this model with data on observed ranges for the basic reproductive ratio (R 0) of nine directly transmitted diseases. I also present results from a new model, the simple stochastic epidemic with delayed-onset intervention, in which an initially supercritical outbreak (R 0 > 1) is brought under control after a delay. Conclusion The coefficient of variation of final outbreak size in the subcritical case (R 0 < 1) will be greater than one for any outbreak in which the removal rate is less than approximately 2.41 times the rate of infectious contacts, implying that for many transmissible diseases precise forecasts of the final outbreak size will be unattainable. In the delayed-onset model, the coefficient of variation (CV) was generally large (CV > 1) and increased with the delay between the start of the epidemic and intervention, and with the average outbreak size. These results suggest that early warning systems for infectious diseases should not focus exclusively on predicting outbreak size but should consider other characteristics of outbreaks such as the timing of disease emergence. PMID:16435887
Kang, Beom Sik; Pugalendhi, GaneshKumar; Kim, Ku-Jin
2017-10-13
Interactions between protein molecules are essential for the assembly, function, and regulation of proteins. The contact region between two protein molecules in a protein complex is usually complementary in shape for both molecules and the area of the contact region can be used to estimate the binding strength between two molecules. Although the area is a value calculated from the three-dimensional surface, it cannot represent the three-dimensional shape of the surface. Therefore, we propose an original concept of two-dimensional contact area which provides further information such as the ruggedness of the contact region. We present a novel algorithm for calculating the binding direction between two molecules in a protein complex, and then suggest a method to compute the two-dimensional flattened area of the contact region between two molecules based on the binding direction.
Assessing the Risk of Inadvertent Nuclear War Between India and Pakistan
2002-12-01
stories/review.htm>. 5 avoided partly as a result of this. Hundreds of nuclear weapons tests were conducted, proving the technical capability of...sites in Cuba. The results of such an attack could have been disastrous, putting conventional systems in direct contact with nuclear systems, and... nuclear weapons and their delivery systems. Finally, India and Pakistan’s nuclear doctrines are compared. These comparisons yield important results
Flores-Campos, R; Estrada-Ruiz, R H; Velarde-Sánchez, E J
2017-11-01
Recycling printed circuit boards using green technology is increasingly important due to the metals these contain and the environmental care that must be taken when separating the different materials. Inverse flotation is a process that can be considered a Green Technology, which separates metallic from non-metallic fractions. The degree of separation depends on how much material is adhered to air bubbles. The contact angle measurement allows to determine, in an easy way, whether the flotation process will occur or not and thus establish a material as hydrophobic or not. With the material directly obtained from the milling process, it was found that the contact angle of the non-metallic fraction-liquid-air system increases as temperature increases. In the same way, the increments in concentration of frother in the liquid increase the contact angle of the non-metallic fraction-liquid-air system. 10ppm of Methyl Isobutyl Carbinol provides the highest contact angle as well as the highest material charging in the bubble. Copyright © 2017 Elsevier Ltd. All rights reserved.
Eye Contact Facilitates Awareness of Faces during Interocular Suppression
ERIC Educational Resources Information Center
Stein, Timo; Senju, Atsushi; Peelen, Marius V.; Sterzer, Philipp
2011-01-01
Eye contact captures attention and receives prioritized visual processing. Here we asked whether eye contact might be processed outside conscious awareness. Faces with direct and averted gaze were rendered invisible using interocular suppression. In two experiments we found that faces with direct gaze overcame such suppression more rapidly than…
NASA Astrophysics Data System (ADS)
Akimoto, Makio; Chen, Yu; Miyazaki, Michio; Yamashita, Toyonobu; Miyakawa, Michio; Hata, Mieko
The skin is unique as an organ that is highly accessible to direct visual inspection with light. Visual inspection of cutaneous morphology is the mainstay of clinical dermatology, but relies heavily on subjective assessment by the skilled dermatologists. We present an imaging colorimeter of non-contact skin color measuring system and some experimented results using such instrument. The system is comprised by a video camera, light source, a real-time image processing board, magneto optics disk and personal computer which controls the entire system. The CIE-L*a*b* uniform color space is used. This system is used for monitoring of some clinical diagnosis. The instrument is non-contact, easy to operate, and has a high precision unlike the conventional colorimeters. This instrument is useful for clinical diagnoses, monitoring and evaluating the effectiveness of treatment.
Dąbrowska, Krystyna
2018-01-01
In all cases when a bacteriophage makes direct contact with a mammalian organism, it may challenge the mammalian immunological system. Its major consequence is production of antibodies specific to the bacteriophage. Here we present protocols applicable in studies of bacteriophage ability to induce specific antibodies. The protocols have been divided into three parts: purification, immunization, and detection (ELISA).
ERIC Educational Resources Information Center
O'Malley, Sinead; Devaney, Carmel
2016-01-01
There is a dearth of research on the experience of motherhood within the Irish prison system. This paper considers the specific issue of facilitating contact between incarcerated mothers and their children. It is based on a study which explores the views of practitioners working directly with mothers in prison on how the mother-child relationship…
Federal Register 2010, 2011, 2012, 2013, 2014
2011-09-30
... Bulletin 737-28A1201, Revision 1, dated May 28, 2009. Subject (d) Joint Aircraft System Component (JASC... control relays in the P91 and P92 power distribution panels for the fuel boost and override pumps with new... INFORMATION CONTACT: Georgios Roussos, Aerospace Engineer, Systems and Equipment Branch, ANM-130S, FAA...
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-18
....regulations.gov or email. The www.regulations.gov Web site is an ``anonymous access'' system, which means EPA.../ . SUPPLEMENTARY INFORMATION: I. Why is EPA using a direct final rule? EPA is publishing this rule without a prior... entity, consult the person listed in the FOR FURTHER INFORMATION CONTACT section. III. What should I...
1985-11-01
Boiler and Pressure Vessel Code HEI Heat Exchanger Institute Heat and Material Balance c. System Description (1) Condenser... Boiler and Pressure Vessel Code "AN(SI B31.1 Power Piping d. System Description (1) Deaerator The deaerator will be d direct contact feedwater heater, and...vent, and drain piping. "b . Applicable Codes ASME Boiler and Pressure Vessel Code "ANSI B31.1 - Power Piping Code
78 FR 37497 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-06-21
... and corrective actions if necessary. That AD resulted from fuel system reviews conducted by the... the fuel tanks are installed, and related investigative and corrective actions if necessary. Since the... CONTACT: Rebel Nichols, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle Aircraft...
78 FR 42415 - Airworthiness Directives; the Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-07-16
... INFORMATION CONTACT: Suzanne Lucier, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle Aircraft... Lucier, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA, Seattle Aircraft Certification Office, 1601... 737-28-1286, dated January 10, 2012. (d) Subject Joint Aircraft System Component (JASC)/Air Transport...
Hemmink, Johanneke D; Morgan, Sophie B; Aramouni, Mario; Everett, Helen; Salguero, Francisco J; Canini, Laetitia; Porter, Emily; Chase-Topping, Margo; Beck, Katy; Loughlin, Ronan Mac; Carr, B Veronica; Brown, Ian H; Bailey, Mick; Woolhouse, Mark; Brookes, Sharon M; Charleston, Bryan; Tchilian, Elma
2016-10-20
Influenza virus infection in pigs is a major farming problem, causing considerable economic loss and posing a zoonotic threat. In addition the pig is an excellent model for understanding immunity to influenza viruses as this is a natural host pathogen system. Experimentally, influenza virus is delivered to pigs intra-nasally, by intra-tracheal instillation or by aerosol, but there is little data comparing the outcome of different methods. We evaluated the shedding pattern, cytokine responses in nasal swabs and immune responses following delivery of low or high dose swine influenza pdmH1N1 virus to the respiratory tract of pigs intra-nasally or by aerosol and compared them to those induced in naturally infected contact pigs. Our data shows that natural infection by contact induces remarkably high innate and adaptive immune response, although the animals were exposed to a very low virus dose. In contacts, the kinetics of virus shedding were slow and prolonged and more similar to the low dose directly infected animals. In contrast the cytokine profile in nasal swabs, antibody and cellular immune responses of contacts more closely resemble immune responses in high dose directly inoculated animals. Consideration of these differences is important for studies of disease pathogenesis and assessment of vaccine protective efficacy.
NASA Astrophysics Data System (ADS)
Ohmori, Shuichi; Narabayashi, Tadashi; Mori, Michitsugu; Iwaki, Chikako; Asanuma, Yutaka; Goto, Shoji
A Steam Injector (SI) is a simple, compact and passive pump and also acts as a high-performance direct-contact heater. This provides SI with capability to serve also as a direct-contact feed-water heater that heats up feed-water by using extracted steam from turbine. Our technology development aims to significantly simplify equipment and reduce physical quantities by applying "High-Efficiency SI", which are applicable to a wide range of operation regimes beyond the performance and applicable range of existing SIs and enables unprecedented multistage and parallel operation, to the low-pressure feed-water heaters and Emergency Core Cooling System of nuclear power plants, as well as achieve high inherent safety to prevent severe accidents by keeping the core covered with water (a Severe Accident-Free Concept). This paper describes the results of the endurance and performance tests of low-pressure SIs for feed-water heaters with Jet-deaerator and core injection system.
Non-contact data access with direction identification for industrial differential serial bus
NASA Astrophysics Data System (ADS)
Xie, Kai; Li, Xiaoping; Zhang, Hanlu; Yang, Ming; Ye, Yinghao
2013-06-01
We propose a non-contact method for accessing data in industrial differential serial bus applications, which could serve as an effective and safe online testing and diagnosing tool. The data stream and the transmission direction are reconstructed simultaneously from the near-field emanations of a twisted pair, eliminating direct contact with the actual conductors, and avoiding damage to the insulation (only the outer sheathing is removed). A non-contact probe with the ability to sense electric and magnetic fields is presented, as are theories for data reconstruction, direction identification, and a circuit implementation. The prototype was built using inexpensive components and then tested on a standard RS-485 industrial serial bus. Experimental results verified the validity of the proposed scheme.
DOE Office of Scientific and Technical Information (OSTI.GOV)
von Sternberg, Alex
The contact control code is a generalized force control scheme meant to interface with a robotic arm being controlled using the Robot Operating System (ROS). The code allows the user to specify a control scheme for each control dimension in a way that many different control task controllers could be built from the same generalized controller. The input to the code includes maximum velocity, maximum force, maximum displacement, and a control law assigned to each direction and the output is a 6 degree of freedom velocity command that is sent to the robot controller.
Experimental Measurements of Spreading of Volatile Liquid Droplets
NASA Technical Reports Server (NTRS)
Zhang, Neng-Li; Chao, David F.
2001-01-01
Based on the laser shadowgraphic system used by the first author of the present paper, a simple optical system, which combined the laser shadowgraphy and the direct magnified-photography, has been developed to measure the contact angle, the spreading speed, and the evaporation rate. Additionally, the system can also visualize thermocapillary convection inside of a sessile drop simultaneously. The experimental results show that evaporation/condensation and thermocapillary convection in the sessile drop induced by the evaporation strongly affects the wetting and spreading of the drop. Condensation always promotes the wetting and spreading of the drop. Evaporation may increase or decrease the contact angle of the evaporating sessile drops, depending on the evaporation rate. The thermocapillary convection in the drop induced by the evaporation enhances the effects of evaporation to suppress the spreading.
Biobriefcase electrostatic aerosol collector
Bell, Perry M [Tracy, CA; Christian, Allen T [Madison, WI; Bailey, Christopher G [Pleasanton, CA; Willis, Ladona [Manteca, CA; Masquelier, Donald A [Tracy, CA; Nasarabadi, Shanavaz L [Livermore, CA
2009-03-17
A system for sampling air and collecting particles entrained in the air comprising a receiving surface, a liquid input that directs liquid to the receiving surface and produces a liquid surface, an air input that directs the air so that the air with particles entrained in the air impact the liquid surface, and an electrostatic contact connected to the liquid that imparts an electric charge to the liquid. The particles potentially including bioagents become captured in the liquid by the air with particles entrained in the air impacting the liquid surface. Collection efficiency is improved by the electrostatic contact electrically charging the liquid. The effects of impaction and adhesion due to electrically charging the liquid allows a unique combination in a particle capture medium that has a low fluid consumption rate while maintaining high efficiency.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Ling, Xue; Wang, Yusheng; Li, Xide, E-mail: lixide@tsinghua.edu.cn
An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects ofmore » the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li–Etsion–Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.« less
Heat-pump cool storage in a clathrate of freon
NASA Astrophysics Data System (ADS)
Tomlinson, J. J.
Presented are the analytical description and assessment of a unique heat pump/storage system in which the conventional evaporator of the vapor compression cycle is replaced by a highly efficient direct contract crystallizer. The thermal storage technique requires the formation of a refrigerant gas hydrate (a clathrate) and exploits an enthalpy of reaction comparable to the heat of fusion of ice. Additional system operational benefits include cool storage at the favorable temperatures of 4 to 7 C (40 to 45 F), and highly efficient heat transfer ates afforded by he direct contact mechanism. In addition, the experimental approach underway at ORNL to study such a system is discussed.
NASA Technical Reports Server (NTRS)
Kirk, J. A.; Studer, P. A.; Evans, H. E.
1976-01-01
A new energy storage system (the mechanical capacitor), using a spokeless magnetically levitated composite ring rotor, is described and design formulas for sizing the components are presented. This new system is configured around a permanent magnet (flux biased) suspension which has active servo control in the radial direction and passive control in the axial direction. The storage ring is used as a moving rotor and electronic commutation of the stationary armature coils is proposed. There is no mechanical contact with the rotating spokeless ring; therefore, long life and near zero rundown losses are projected. A 7-kW h system is sized to demonstrate feasibility. A literature review of flywheel energy storage systems is also presented and general formulas are developed for comparing rotor geometries.
Micro-macro correlations and anisotropy in granular assemblies under uniaxial loading and unloading.
Imole, Olukayode I; Wojtkowski, Mateusz; Magnanimo, Vanessa; Luding, Stefan
2014-04-01
The influence of contact friction on the behavior of dense, polydisperse granular assemblies under uniaxial (oedometric) loading and unloading deformation is studied using discrete element simulations. Even though the uniaxial deformation protocol is one of the "simplest" element tests possible, the evolution of the structural anisotropy necessitates its careful analysis and understanding, since it is the source of interesting and unexpected observations. On the macroscopic, homogenized, continuum scale, the deviatoric stress ratio and the deviatoric fabric, i.e., the microstructure behave in a different fashion during uniaxial loading and unloading. The maximal stress ratio and strain increase with increasing contact friction. In contrast, the deviatoric fabric reaches its maximum at a unique strain level independent of friction, with the maximal value decreasing with friction. For unloading, both stress and fabric respond to unloading strain with a friction-dependent delay but at different strains. On the micro-level, a friction-dependent non-symmetry of the proportion of weak (strong) and sliding (sticking) contacts with respect to the total contacts during loading and unloading is observed. Coupled to this, from the directional probability distribution, the "memory" and history-dependent behavior of granular systems is confirmed. Surprisingly, while a rank-2 tensor is sufficient to describe the evolution of the normal force directions, a sixth order harmonic approximation is necessary to describe the probability distribution of contacts, tangential force, and mobilized friction. We conclude that the simple uniaxial deformation activates microscopic phenomena not only in the active Cartesian directions, but also at intermediate orientations, with the tilt angle being dependent on friction, so that this microstructural features cause the interesting, nontrivial macroscopic behavior.
Bubble dynamics in a compressible liquid in contact with a rigid boundary
Wang, Qianxi; Liu, Wenke; Zhang, A. M.; Sui, Yi
2015-01-01
A bubble initiated near a rigid boundary may be almost in contact with the boundary because of its expansion and migration to the boundary, where a thin layer of water forms between the bubble and the boundary thereafter. This phenomenon is modelled using the weakly compressible theory coupled with the boundary integral method. The wall effects are modelled using the imaging method. The numerical instabilities caused by the near contact of the bubble surface with the boundary are handled by removing a thin layer of water between them and joining the bubble surface with its image to the boundary. Our computations correlate well with experiments for both the first and second cycles of oscillation. The time history of the energy of a bubble system follows a step function, reducing rapidly and significantly because of emission of shock waves at inception of a bubble and at the end of collapse but remaining approximately constant for the rest of the time. The bubble starts being in near contact with the boundary during the first cycle of oscillation when the dimensionless stand-off distance γ = s/Rm < 1, where s is the distance of the initial bubble centre from the boundary and Rm is the maximum bubble radius. This leads to (i) the direct impact of a high-speed liquid jet on the boundary once it penetrates through the bubble, (ii) the direct contact of the bubble at high temperature and high pressure with the boundary, and (iii) the direct impingement of shock waves on the boundary once emitted. These phenomena have clear potential to damage the boundary, which are believed to be part of the mechanisms of cavitation damage. PMID:26442148
Wettability and impact dynamics of water droplets on rice ( Oryza sativa L.) leaves
NASA Astrophysics Data System (ADS)
Kwon, Dae Hee; Huh, Hyung Kyu; Lee, Sang Joon
2014-03-01
We investigated the wettability and impact dynamics of water droplets on rice leaves at various leaf inclination angles and orientations. Contact angle, contact angle hysteresis (CAH), and roll-off angle ( α roll) of water droplets were measured quantitatively. Results showed that droplet motion exhibited less resistance along the longitudinal direction. Impact dynamic parameters, such as impact behaviors, maximum spreading factor, contact distance, and contact time were also investigated. Three different impact behaviors were categorized based on the normal component of Weber number irrespective of the inclination angle of the rice leaf. The asymmetric impact behavior induced by the tangential Weber number was also identified. Variation in the maximum spreading factor according to the normal Weber number was measured and compared with theoretical value obtained according to scaling law to show the wettability of the rice leaves. The contact distance of the impacting droplets depended on the inclination angle of the leaves. Along the longitudinal direction of rice leaves, contact distance was farther than that along the transverse direction. This result is consistent with the smaller values of CAH and α roll along the longitudinal direction.
Contact angle change during evaporation of near-critical liquids
NASA Astrophysics Data System (ADS)
Nikolayev, Vadim; Hegseth, John; Beysens, Daniel
1998-03-01
An unexpected change of the dynamic contact angle was recently observed in a near-critical liquid-gas system in a space experiment. While the near-critical liquid completely wets a solid under equilibrium conditions, the apparent contact angle changed from 0^circ to about 120^circ during evaporation. We propose an explanation for this phenomenon by taking into account vapor recoil due to evaporation (motion of the vapor from the free liquid surface). This force is normal to the vapor-liquid interface and is directed towards the liquid. It increases sharply near the triple contact line. Near the critical point, where the surface tension force is very weak, the vapor recoil force can be important enough to change the apparent contact angle. A similar effect can also explain the drying of a heater during boiling at high heat flux. The drying greatly reduces the heat transfer to the liquid causing the heater to melt. This phenomenon is called ``boiling crisis", ``burnout" or ``Departure from Nuclear Boiling".
Microstructure, electrical properties, and thermal stability of Au-based ohmic contacts to p-GaN
DOE Office of Scientific and Technical Information (OSTI.GOV)
Smith, L.L.; Davis, R.F.; Kim, M.J.
1997-09-01
The work described in this paper is part of a systematic study of ohmic contact strategies for GaN-based semiconductors. Au contacts exhibited ohmic behavior on p-GaN when annealed at high temperature. The specific contact resistivity ({rho}{sub c}) calculated from TLM measurements on Au/p-GaN contacts was 53{Omega}{center_dot}cm{sup 2} after annealing at 800{degree}C. Multilayer Au/Mg/Au/p-GaN contacts exhibited linear, ohmic current-voltage (I-V) behavior in the as-deposited condition with {rho}{sub c}=214{Omega}{center_dot}cm{sup 2}. The specific contact resistivity of the multilayer contact increased significantly after rapid thermal annealing (RTA) through 725{degree}C. Cross-sectional microstructural characterization of the Au/p-GaN contact system via high-resolution electron microscopy (HREM) revealed thatmore » interfacial secondary phase formation occurred during high-temperature treatments, which coincided with the improvement of contact performance. In the as-deposited multilayer Au/Mg/Au/p-GaN contact, the initial 32 nm Au layer was found to be continuous. However, Mg metal was found in direct contact with the GaN in many places in the sample after annealing at 725{degree}C for 15 s. The resultant increase in contact resistance is believed to be due to the barrier effect increased by the presence of the low work function Mg metal. {copyright} {ital 1997 Materials Research Society.}« less
78 FR 7642 - Airworthiness Directives; Piper Aircraft, Inc.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-02-04
...., Washington, DC 20590. FOR FURTHER INFORMATION CONTACT: Hector Hernandez, Aerospace Engineer, FAA, Atlanta.... Conclusion We reviewed the relevant data, considered the comments received, and determined that air safety... work-hours x $85 per hour = $608 $1,458 system--per set of cables. $850. Authority for This Rulemaking...
Direct-contact closed-loop heat exchanger
Berry, Gregory F.; Minkov, Vladimir; Petrick, Michael
1984-01-01
A high temperature heat exchanger with a closed loop and a heat transfer liquid within the loop, the closed loop having a first horizontal channel with inlet and outlet means for providing direct contact of a first fluid at a first temperature with the heat transfer liquid, a second horizontal channel with inlet and outlet means for providing direct contact of a second fluid at a second temperature with the heat transfer liquid, and means for circulating the heat transfer liquid.
Non-contact optoacoustic imaging by raster scanning a piezoelectric air-coupled transducer
NASA Astrophysics Data System (ADS)
Deán-Ben, X. Luís.; Pang, Genny A.; Montero de Espinosa, Francisco; Razansky, Daniel
2016-03-01
Optoacoustic techniques rely on ultrasound transmission between optical absorbers within tissues and the measurement location. Much like in echography, commonly used piezoelectric transducers require either direct contact with the tissue or through a liquid coupling medium. The contact nature of this detection approach then represents a disadvantage of standard optoacoustic systems with respect to other imaging modalities (including optical techniques) in applications where non-contact imaging is needed, e.g. in open surgeries or when burns or other lesions are present in the skin. Herein, non-contact optoacoustic imaging using raster-scanning of a spherically-focused piezoelectric air-coupled ultrasound transducer is demonstrated. When employing laser fluence levels not exceeding the maximal permissible human exposure, it is shown possible to attain detectable signals from objects as small as 1 mm having absorption properties representative of blood at near-infrared wavelengths with a relatively low number of averages. Optoacoustic images from vessel-mimicking tubes embedded in an agar phantom are further showcased. The initial results indicate that the air-coupled ultrasound detection approach can be potentially made suitable for non-contact biomedical imaging with optoacoustics.
Measurement of stress distributions in truck tyre contact patch in real rolling conditions
NASA Astrophysics Data System (ADS)
Anghelache, Gabriel; Moisescu, Raluca
2012-12-01
Stress distributions on three orthogonal directions have been measured across the contact patch of truck tyres using the complex measuring system that contains a transducer assembly with 30 sensing elements placed in the road surface. The measurements have been performed in straight line, in real rolling conditions. Software applications for calibration, data acquisition, and data processing were developed. The influence of changes in inflation pressure and rolling speed on the shapes and sizes of truck tyre contact patch has been shown. The shapes and magnitudes of normal, longitudinal, and lateral stress distributions, measured at low speed, have been presented and commented. The effect of wheel toe-in and camber on the stress distribution results was observed. The paper highlights the impact of the longitudinal tread ribs on the shear stress distributions. The ratios of stress distributions in the truck tyre contact patch have been computed and discussed.
A linear complementarity method for the solution of vertical vehicle-track interaction
NASA Astrophysics Data System (ADS)
Zhang, Jian; Gao, Qiang; Wu, Feng; Zhong, Wan-Xie
2018-02-01
A new method is proposed for the solution of the vertical vehicle-track interaction including a separation between wheel and rail. The vehicle is modelled as a multi-body system using rigid bodies, and the track is treated as a three-layer beam model in which the rail is considered as an Euler-Bernoulli beam and both the sleepers and the ballast are represented by lumped masses. A linear complementarity formulation is directly established using a combination of the wheel-rail normal contact condition and the generalised-α method. This linear complementarity problem is solved using the Lemke algorithm, and the wheel-rail contact force can be obtained. Then the dynamic responses of the vehicle and the track are solved without iteration based on the generalised-α method. The same equations of motion for the vehicle and track are adopted at the different wheel-rail contact situations. This method can remove some restrictions, that is, time-dependent mass, damping and stiffness matrices of the coupled system, multiple equations of motion for the different contact situations and the effect of the contact stiffness. Numerical results demonstrate that the proposed method is effective for simulating the vehicle-track interaction including a separation between wheel and rail.
NASA Astrophysics Data System (ADS)
Moisescu, Alexandra-Raluca; Anghelache, Gabriel
2017-10-01
In the modern context of automobile integration with the emerging technologies of the interconnected society, the interaction between tyre and road is an element of major importance for automobile safety systems such as the intelligent tyres, as well as for passenger comfort, fuel economy, environmental protection, infrastructure and vehicle durability. The tyre-road contact generates the distribution of forces exerted on each unit area in the contact patch, therefore the distribution of contact stresses on three orthogonal directions. The numerical investigation of stresses distribution in the contact patch requires the development of finite element models capable of accurately describing the interaction between tyre and rolling surface. The complex finite element model developed for the 11R22.5 truck tyre has been used for investigating the influence of vertical force on the distributions of contact stresses. In addition to these contributions, the paper presents aspects related to the simulation of truck tyre radial stiffness. The influence of tyre rolling has not been taken into consideration, as the purpose of the current research is the investigation of tyre-road contact in stationary conditions.
A Graphical User Interface for the Low Cost Combat Direction System
1991-09-16
the same tasks. These shipboard tasks, which include contact management , moving geometry calculations, intelligence compila- tion, area plotting and...Display Defaults Analysis This category covers a wide range of required data input and system configuration issues. To keep the screen display manageable ...parts or dialog boxes. The implementation of an Ada application using STARS is quite straightforward, although knowlede of X Protocol primitives is
Steenbeek, Henderien; van der Aalsvoort, Diny; van Geert, Paul
2014-07-01
This study was focused on the role of gender-related differences in collaborative play, by examining properties of play as a complex system, and by using micro-genetic analysis techniques. A complex dynamic systems model of dyadic play was used to make predictions with regard to duration and number of contact-episodes during play of same-sex dyads, both on the micro- (i.e., per individual session), meso- (i.e., in smoothed data), and macro time scale (i.e., the change over six consecutive play sessions). The empirical data came from a study that examined the collaborative play skills of children who experienced six twenty minute play sessions within a three week period of time. Monte Carlo permutation analyses were used to compare model predictions and empirical data. The findings point to strongly asymmetric distributions in the duration and number of contact episodes in all dyads over the six sessions, as a direct consequence of the underlying dynamics of the play system. The model prediction that girls-dyads would show longer contact episodes than boys-dyads was confirmed, but the prediction regarding the difference in number of peaks was not confirmed. In addition, the majority of the model predictions regarding changes over the course of six sessions were consistent with the data. That is, the average duration and the maximum duration of contact-episodes increases both in boys-dyads and girls-dyads, but differences occur in the strength of the increase. Contrary to expectation, the number of contact-episodes decreases both in boys-dyads and in girls-dyads.
Claxton, Gerald L.
1999-01-01
A stabilizing suspension system is provided for vehicles carrying telescopic booms or aerial work platforms having a fixed axle and a oscillating axle. Hydraulic cylinders are connected to each end of the oscillating axle, each cylinder being capable of extending and retracting. An off level sensor senses the angle of tilt of the chassis in both left and right directions and, when a predetermined threshold of tilt has been detected, the hydraulic cylinder on the downhill side of the chassis is locked against retracting, but is free to move in the downhill direction to allow the downhill wheel to remain in contact with the ground.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-04-23
... requests for medical devices that come into direct or indirect contact with the human body in order to... the human body in order to determine the potential toxicity resulting from contact of the component... direct or indirect contact with the human body. This document addresses the following issues: (1) Test...
Toxicity of aerosols to larch casebearer larvae
Robert L. Lyon; Margaret E. May
1970-01-01
Six insecticides were tested in the laboratory as aerosols against larch casebeare1 larvae. Their toxicity was determined by both direct contact and residual contact on filter paper. All six were highly toxic at less than 1.05 µg/ cm2 (the equivalent of 1.5 oz./acre). In decreasing order of toxicity at LD90 (direct contact...
Contact force structure and force chains in 3D sheared granular systems
NASA Astrophysics Data System (ADS)
Mair, Karen; Jettestuen, Espen; Abe, Steffen
2010-05-01
Faults often exhibit accumulations of granular debris, ground up to create a layer of rock flour or fault gouge separating the rigid fault walls. Numerical simulations and laboratory experiments of sheared granular materials, suggest that applied loads are preferentially transmitted across such systems by transient force networks that carry enhanced forces. The characterisation of such features is important since their nature and persistence almost certainly influence the macroscopic mechanical stability of these systems and potentially that of natural faults. 3D numerical simulations of granular shear are a valuable investigation tool since they allow us to track individual particle motions, contact forces and their evolution during applied shear, that are difficult to view directly in laboratory experiments or natural fault zones. In characterising contact force distributions, it is important to use global structure measures that allow meaningful comparisons of granular systems having e.g. different grain size distributions, as may be expected at different stages of a fault's evolution. We therefore use a series of simple measures to characterise the structure, such as distributions and correlations of contact forces that can be mapped onto a force network percolation problem as recently proposed by Ostojic and coworkers for 2D granular systems. This allows the use of measures from percolation theory to both define and characterise the force networks. We demonstrate the application of this method to 3D simulations of a sheared granular material. Importantly, we then compare our measure of the contact force structure with macroscopic frictional behaviour measured at the boundaries of our model to determine the influence of the force networks on macroscopic mechanical stability.
1986-07-01
for vapor transfer. A toxicological test was c’isigned to evaluate the above models. Animals were exposed to agant vapor and to direct contact with...surfaces contaminated with HD. If the toxicological response is the same from direct contact as from vapor, then only vapor transfer is significant...study were chosen to deter- mine whether partitioning is applicable to nonpermeable materials such as the polymethyl methacrylate ( PMMA ) sheeting or to
Direct-contact closed-loop heat exchanger
Berry, G.F.; Minkov, V.; Petrick, M.
1981-11-02
A high temperature heat exchanger is disclosed which has a closed loop and a heat transfer liquid within the loop, the closed loop having a first horizontal channel with inlet and outlet means for providing direct contact of a first fluid at a first temperature with the heat transfer liquid, a second horizontal channel with inlet and outlet means for providing direct contact of a second fluid at a second temperature with the heat transfer liquid, and means for circulating the heat transfer liquid.
Cocco, Simona; Monasson, Remi; Weigt, Martin
2013-01-01
Various approaches have explored the covariation of residues in multiple-sequence alignments of homologous proteins to extract functional and structural information. Among those are principal component analysis (PCA), which identifies the most correlated groups of residues, and direct coupling analysis (DCA), a global inference method based on the maximum entropy principle, which aims at predicting residue-residue contacts. In this paper, inspired by the statistical physics of disordered systems, we introduce the Hopfield-Potts model to naturally interpolate between these two approaches. The Hopfield-Potts model allows us to identify relevant ‘patterns’ of residues from the knowledge of the eigenmodes and eigenvalues of the residue-residue correlation matrix. We show how the computation of such statistical patterns makes it possible to accurately predict residue-residue contacts with a much smaller number of parameters than DCA. This dimensional reduction allows us to avoid overfitting and to extract contact information from multiple-sequence alignments of reduced size. In addition, we show that low-eigenvalue correlation modes, discarded by PCA, are important to recover structural information: the corresponding patterns are highly localized, that is, they are concentrated in few sites, which we find to be in close contact in the three-dimensional protein fold. PMID:23990764
Wynn, Michelle L.; Kulesa, Paul M.; Schnell, Santiago
2012-01-01
Follow-the-leader chain migration is a striking cell migratory behaviour observed during vertebrate development, adult neurogenesis and cancer metastasis. Although cell–cell contact and extracellular matrix (ECM) cues have been proposed to promote this phenomenon, mechanisms that underlie chain migration persistence remain unclear. Here, we developed a quantitative agent-based modelling framework to test mechanistic hypotheses of chain migration persistence. We defined chain migration and its persistence based on evidence from the highly migratory neural crest model system, where cells within a chain extend and retract filopodia in short-lived cell contacts and move together as a collective. In our agent-based simulations, we began with a set of agents arranged as a chain and systematically probed the influence of model parameters to identify factors critical to the maintenance of the chain migration pattern. We discovered that chain migration persistence requires a high degree of directional bias in both lead and follower cells towards the target. Chain migration persistence was also promoted when lead cells maintained cell contact with followers, but not vice-versa. Finally, providing a path of least resistance in the ECM was not sufficient alone to drive chain persistence. Our results indicate that chain migration persistence depends on the interplay of directional cell movement and biased cell–cell contact. PMID:22219399
NASA Astrophysics Data System (ADS)
Robertson, Luke D.; Kane, B. E.
Quantum point contacts (QPCs) realized in materials with anisotropic electron mass, such as Si, may exhibit valley filter phenomena leading to extreme sensitivity to single donor occupancy, and thus are of interest to measurement schemes for donor-based quantum information processing. To this end, we have developed ambipolar devices on a H-Si(111):Si(100)/SiO2 flip-chip assembly which utilize in-plane, degenerately doped n+ (P) and p+ (B) contacts to probe transport in a 2D electron system (2DES). In addition to providing electrostatic isolation of carriers, these p-type contacts can be used as lateral depletion gates to modulate the 2DES conductance, and if extended to the nanoscale can lead to 1D confinement and quantized conductance of the 2DES. In this talk, I will describe our efforts to use a Ga focused-ion beam for direct-write implant lithography to pattern QPCs and Ga nanowires on H-Si(111) surfaces. I will present low temperature (4.2K) conductance data collected on 30nm Ga nanowires to demonstrate their effectiveness as lateral depletion gates, and discuss on going measurements to confine and modulate the conductance of the 2DES using Ga QPCs.
Ray, Arja; Lee, Oscar; Win, Zaw; Edwards, Rachel M.; Alford, Patrick W.; Kim, Deok-Ho; Provenzano, Paolo P.
2017-01-01
Directed migration by contact guidance is a poorly understood yet vital phenomenon, particularly for carcinoma cell invasion on aligned collagen fibres. We demonstrate that for single cells, aligned architectures providing contact guidance cues induce constrained focal adhesion maturation and associated F-actin alignment, consequently orchestrating anisotropic traction stresses that drive cell orientation and directional migration. Consistent with this understanding, relaxing spatial constraints to adhesion maturation either through reduction in substrate alignment density or reduction in adhesion size diminishes the contact guidance response. While such interactions allow single mesenchymal-like cells to spontaneously ‘sense' and follow topographic alignment, intercellular interactions within epithelial clusters temper anisotropic cell–substratum forces, resulting in substantially lower directional response. Overall, these results point to the control of contact guidance by a balance of cell–substratum and cell–cell interactions, modulated by cell phenotype-specific cytoskeletal arrangements. Thus, our findings elucidate how phenotypically diverse cells perceive ECM alignment at the molecular level. PMID:28401884
A locomotive-track coupled vertical dynamics model with gear transmissions
NASA Astrophysics Data System (ADS)
Chen, Zaigang; Zhai, Wanming; Wang, Kaiyun
2017-02-01
A gear transmission system is a key element in a locomotive for the transmission of traction or braking forces between the motor and the wheel-rail interface. Its dynamic performance has a direct effect on the operational reliability of the locomotive and its components. This paper proposes a comprehensive locomotive-track coupled vertical dynamics model, in which the locomotive is driven by axle-hung motors. In this coupled dynamics model, the dynamic interactions between the gear transmission system and the other components, e.g. motor and wheelset, are considered based on the detailed analysis of its structural properties and working mechanism. Thus, the mechanical transmission system for power delivery from the motor to the wheelset via gear transmission is coupled with a traditional locomotive-track dynamics system via the wheel-rail contact interface and the gear mesh interface. This developed dynamics model enables investigations of the dynamic performance of the entire dynamics system under the excitations from the wheel-rail contact interface and/or the gear mesh interface. Dynamic interactions are demonstrated by numerical simulations using this dynamics model. The results indicate that both of the excitations from the wheel-rail contact interface and the gear mesh interface have a significant effect on the dynamic responses of the components in this coupled dynamics system.
Design of a novel system for spectroscopy measurements of the aqueous humor
NASA Astrophysics Data System (ADS)
Miller, Joe; Uttamchandani, Deepak G.
2001-06-01
The authors report on the design of a system which will enable real time measurements of (therapeutic) drug concentrations in the anterior chamber of the eye. Currently the concentration of therapeutic drugs in the anterior chamber is determined by analyzing samples which have been removed from the aqueous humor of laboratory animal eyes. This sampling via paracentesis can be painful and does not provide a continuous measurement. Our system will be far less invasive, removing the need for sampling via paracentesis, and also providing a continuous measurement, enabling a more complete understanding of the kinetics of ophthalmic drugs. A key component in our novel system is a specially constructed contact lens. We report on the design, optimization and manufacture of such a contact lens system capable of directing UV/VIS light in, across and out of the anterior chamber of the eye, thereby enabling absorption spectroscopy measurements of the aqueous humor to be undertaken. Design of the one piece contact lens/mirror system was achieved using the Zemax optical design software package and the lens was fabricated from synthetic fused silica. Results from modeling of the lens and experimental measurements on light propagation across the anterior chamber of animal eyes assisted by the lens will be reported.
75 FR 50878 - Airworthiness Directives; McDonnell Douglas Corporation Model MD-90-30 Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2010-08-18
... support fitting for the MLG failing during gear extension and subsequently damaging the hydraulic system... retract cylinder support fitting for the MLG, which could adversely affect the airplane's safe landing... service information identified in this AD, contact Boeing Commercial Airplanes, Attention: Data & Services...
Sewage Disposal in Port Harcourt, Nigeria.
ERIC Educational Resources Information Center
Ayotamuno, M. J.
1993-01-01
This survey of the Port Harcourt, Nigeria, sewage disposal system exemplifies sewage disposal in the developing world. Results reveal that some well-constructed and maintained drains, as well as many open drains and septic tanks, expose women and children to the possibility of direct contact with parasitic organisms and threaten water resources.…
77 FR 10693 - Airworthiness Directives; Airbus Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2012-02-23
... the position resolvers of the angle of attack (AOA) vane, which was a result of incorrect removal of... non-activation of the AOA protection systems which, during flight at a high angle of attack, could... information identified in this proposed AD, contact Airbus, Airworthiness Office--EAS, 1 Rond Point Maurice...
76 FR 5370 - Potential Addition of Vapor Intrusion Component to the Hazard Ranking System
Federal Register 2010, 2011, 2012, 2013, 2014
2011-01-31
... structures through the subsurface environment and thus, enabling sites with vapor intrusion contamination to... contamination to be included in an HRS evaluation. Presented below is background information on the HRS, its... facility, the potential for contamination of drinking water supplies, direct human contact, destruction of...
A CMOS camera-based system for clinical photoplethysmographic applications
NASA Astrophysics Data System (ADS)
Humphreys, Kenneth; Markham, Charles; Ward, Tomas E.
2005-06-01
In this work an image-based photoplethysmography (PPG) system is developed and tested against a conventional finger-based system as commonly used in clinical practise. A PPG is essentially an optical instrument consisting of a near infrared (NIR) source and detector that is capable of tracking blood flow changes in body tissue. When used with a number of wavelengths in the NIR band blood oxygenation changes as well as other blood chemical signatures can be ascertained yielding a very useful device in the clinical realm. Conventionally such a device requires direct contact with the tissue under investigation which eliminates the possibility of its use for applications like wound management where the tissue oxygenation measurement could be extremely useful. To circumnavigate this shortcoming we have developed a CMOS camera-based system, which can successfully extract the PPG signal without contact with the tissue under investigation. A comparison of our results with conventional techniques has yielded excellent results.
Plasma contactor technology for Space Station Freedom
NASA Technical Reports Server (NTRS)
Patterson, Michael J.; Hamley, John A.; Sarver-Verhey, Timothy; Soulas, George C.; Parkes, James; Ohlinger, Wayne L.; Schaffner, Michael S.; Nelson, Amy
1993-01-01
Hollow cathode plasma contactors were baselined for Space Station Freedom (SSF) to control the electrical potentials of surfaces to eliminate/mitigate damaging interactions with the space environment. The system represents a dual-use technology which is a direct outgrowth of the NASA electric propulsion program and in particular the technology development effort on ion thruster systems. Specific efforts include optimizing the design and configuration of the contactor, validating its required lifetime, and characterizing the contactor plume and electromagnetic interference. The plasma contact or subsystems include the plasma contact or unit, a power electronics unit, and an expellant management unit. Under this program these will all be brought to breadboard and engineering model development status. New test facilities were developed, and existing facilities were augmented, to support characterizations and life testing of contactor components and systems. The magnitude, scope, and status of the plasma contactor hardware development program now underway and preliminary test results on system components are discussed.
Zhang, Lei; Li, Yun-xia; Kang, Yan-feng; Yang, Guang-ju; Xie, Qiu-fei
2014-02-18
To evaluate the relationship of incisal point displacements in the mandibular retruded contact position (RCP) between the self-controlled retruded approach and bimanual manipulation method. Twelve healthy young volunteers were selected. The RCP was guided through the self-controlled retruded approach and bimanual manipulation method. The track of the incisal point was recorded, using the mandibular movement trace recording system. The movement direction of the incisal point in horizontal plane was observed. The distance between the incisal point of the RCP and intercuspal contact position (ICP) was measured. Except one volunteer's incisal point movement direction of the RCP was oblique, others were straight toward posterior. The displacements of the incisal point from the ICP to RCP guided through self-controlled approach and bimanual manipulation method were (1.15 ± 0.64) mm, (0.98 ± 0.29) mm respectively. There was no statistical significance between the two methods (P > 0.05). The displacements of the incisal point from the ICP to RCP guided through self-controlled approach and bimanual manipulation method are approximately the same.
Systems and methods for rebalancing redox flow battery electrolytes
Pham, Ai Quoc; Chang, On Kok
2015-03-17
Various methods of rebalancing electrolytes in a redox flow battery system include various systems using a catalyzed hydrogen rebalance cell configured to minimize the risk of dissolved catalyst negatively affecting flow battery performance. Some systems described herein reduce the chance of catalyst contamination of RFB electrolytes by employing a mediator solution to eliminate direct contact between the catalyzed membrane and the RFB electrolyte. Other methods use a rebalance cell chemistry that maintains the catalyzed electrode at a potential low enough to prevent the catalyst from dissolving.
Characterizing granular networks using topological metrics
NASA Astrophysics Data System (ADS)
Dijksman, Joshua A.; Kovalcinova, Lenka; Ren, Jie; Behringer, Robert P.; Kramar, Miroslav; Mischaikow, Konstantin; Kondic, Lou
2018-04-01
We carry out a direct comparison of experimental and numerical realizations of the exact same granular system as it undergoes shear jamming. We adjust the numerical methods used to optimally represent the experimental settings and outcomes up to microscopic contact force dynamics. Measures presented here range from microscopic through mesoscopic to systemwide characteristics of the system. Topological properties of the mesoscopic force networks provide a key link between microscales and macroscales. We report two main findings: (1) The number of particles in the packing that have at least two contacts is a good predictor for the mechanical state of the system, regardless of strain history and packing density. All measures explored in both experiments and numerics, including stress-tensor-derived measures and contact numbers depend in a universal manner on the fraction of nonrattler particles, fNR. (2) The force network topology also tends to show this universality, yet the shape of the master curve depends much more on the details of the numerical simulations. In particular we show that adding force noise to the numerical data set can significantly alter the topological features in the data. We conclude that both fNR and topological metrics are useful measures to consider when quantifying the state of a granular system.
Spin pumping damping and magnetic proximity effect in Pd and Pt spin-sink layers
NASA Astrophysics Data System (ADS)
Caminale, M.; Ghosh, A.; Auffret, S.; Ebels, U.; Ollefs, K.; Wilhelm, F.; Rogalev, A.; Bailey, W. E.
2016-07-01
We investigated the spin pumping damping contributed by paramagnetic layers (Pd, Pt) in both direct and indirect contact with ferromagnetic Ni81Fe19 films. We find a nearly linear dependence of the interface-related Gilbert damping enhancement Δ α on the heavy-metal spin-sink layer thicknesses tN in direct-contact Ni81Fe19 /(Pd, Pt) junctions, whereas an exponential dependence is observed when Ni81Fe19 and (Pd, Pt) are separated by 3 nm Cu. We attribute the quasilinear thickness dependence to the presence of induced moments in Pt, Pd near the interface with Ni81Fe19 , quantified using x-ray magnetic circular dichroism measurements. Our results show that the scattering of pure spin current is configuration-dependent in these systems and cannot be described by a single characteristic length.
[Interactions of 1A2 insulator with promoter of hsp 70 gene in Drosophila melanogaster].
Chetverina, D A; Elizar'ev, P V; Georgiev, P G; Erokhin, M M
2013-04-01
Insulators are regulatory DNA elements that participate in the modulation of the interactions between enhancers and promoters. Depending on the situation, insulators can either stabilize or destroy the contacts between enhancers and promoters. A possible explanation for the activity of insulators is their ability to directly interact with gene promoters. In the present study, it was demonstrated that, in model systems, a 1A2 insulator could interact with the core sequence of an hsp70 promoter. In this case, the insulator protein CP190 is found on the hsp70 promoter, which depends on the presence of an insulator in the transgene. The data obtained are consistent with the model, which implies that direct contacts between insulators and promoters make a considerable contribution to the modulation of the interactions between insulators and promoters.
Architecture of GnRH-Gonadotrope-Vasculature Reveals a Dual Mode of Gonadotropin Regulation in Fish.
Golan, Matan; Zelinger, Einat; Zohar, Yonathan; Levavi-Sivan, Berta
2015-11-01
The function and components of the hypothalamic-pituitary axis are conserved among vertebrates; however, in fish, a neuroglandular mode of delivery (direct contact between axons and endocrine cells) was considered dominant, whereas in tetrapods hypothalamic signals are relayed to their targets via the hypophysial portal blood system (neurovascular delivery mode). By using a transgenic zebrafish model we studied the functional and anatomical aspects of gonadotrope regulation thus revisiting the existing model. FSH cells were found to be situated close to the vasculature whereas the compact organization of LH cells prevented direct contact of all cells with the circulation. GnRH3 fibers formed multiple boutons upon reaching the pituitary, but most of these structures were located in the neurohypophysis rather than adjacent to gonadotropes. A close association was observed between FSH cells and GnRH3 boutons, but only a fifth of the LH cells were in direct contact with GnRH3 axons, suggesting that FSH cells are more directly regulated than LH cells. GnRH3 fibers closely followed the vasculature in the neurohypophysis and formed numerous boutons along these tracts. These vessels were found to be permeable to relatively large molecules, suggesting the uptake of GnRH3 peptides. Our findings have important implications regarding the differential regulation of LH and FSH and contradict the accepted notion that fish pituitary cells are mostly regulated directly by hypothalamic fibers. Instead, we provide evidence that zebrafish apply a dual mode of gonadotrope regulation by GnRH3 that combines both neuroglandular and neurovascular components.
Mentalizing eye contact with a face on a video: Gaze direction does not influence autonomic arousal.
Lyyra, Pessi; Myllyneva, Aki; Hietanen, Jari K
2018-04-26
Recent research has revealed enhanced autonomic and subjective responses to eye contact only when perceiving another live person. However, these enhanced responses to eye contact are abolished if the viewer believes that the other person is not able to look back at the viewer. We purported to investigate whether this "genuine" eye contact effect can be reproduced with pre-recorded videos of stimulus persons. Autonomic responses, gaze behavior, and subjective self-assessments were measured while participants viewed pre-recorded video persons with direct or averted gaze, imagined that the video person was real, and mentalized that the person could see them or not. Pre-recorded videos did not evoke similar physiological or subjective eye contact effect as previously observed with live persons, not even when the participants were mentalizing being seen by the person. Gaze tracking results showed, however, increased attention allocation to faces with direct gaze compared to averted gaze directions. The results suggest that elicitation of the physiological arousal in response to genuine eye contact seems to require spontaneous experience of seeing and of being seen by another individual. © 2018 Scandinavian Psychological Associations and John Wiley & Sons Ltd.
Optimized programming algorithm for cylindrical and directional deep brain stimulation electrodes.
Anderson, Daria Nesterovich; Osting, Braxton; Vorwerk, Johannes; Dorval, Alan D; Butson, Christopher R
2018-04-01
Deep brain stimulation (DBS) is a growing treatment option for movement and psychiatric disorders. As DBS technology moves toward directional leads with increased numbers of smaller electrode contacts, trial-and-error methods of manual DBS programming are becoming too time-consuming for clinical feasibility. We propose an algorithm to automate DBS programming in near real-time for a wide range of DBS lead designs. Magnetic resonance imaging and diffusion tensor imaging are used to build finite element models that include anisotropic conductivity. The algorithm maximizes activation of target tissue and utilizes the Hessian matrix of the electric potential to approximate activation of neurons in all directions. We demonstrate our algorithm's ability in an example programming case that targets the subthalamic nucleus (STN) for the treatment of Parkinson's disease for three lead designs: the Medtronic 3389 (four cylindrical contacts), the direct STNAcute (two cylindrical contacts, six directional contacts), and the Medtronic-Sapiens lead (40 directional contacts). The optimization algorithm returns patient-specific contact configurations in near real-time-less than 10 s for even the most complex leads. When the lead was placed centrally in the target STN, the directional leads were able to activate over 50% of the region, whereas the Medtronic 3389 could activate only 40%. When the lead was placed 2 mm lateral to the target, the directional leads performed as well as they did in the central position, but the Medtronic 3389 activated only 2.9% of the STN. This DBS programming algorithm can be applied to cylindrical electrodes as well as novel directional leads that are too complex with modern technology to be manually programmed. This algorithm may reduce clinical programming time and encourage the use of directional leads, since they activate a larger volume of the target area than cylindrical electrodes in central and off-target lead placements.
Response of jammed packings to thermal fluctuations
NASA Astrophysics Data System (ADS)
Wu, Qikai; Bertrand, Thibault; Shattuck, Mark D.; O'Hern, Corey S.
2017-12-01
We focus on the response of mechanically stable (MS) packings of frictionless, bidisperse disks to thermal fluctuations, with the aim of quantifying how nonlinearities affect system properties at finite temperature. In contrast, numerous prior studies characterized the structural and mechanical properties of MS packings of frictionless spherical particles at zero temperature. Packings of disks with purely repulsive contact interactions possess two main types of nonlinearities, one from the form of the interaction potential (e.g., either linear or Hertzian spring interactions) and one from the breaking (or forming) of interparticle contacts. To identify the temperature regime at which the contact-breaking nonlinearities begin to contribute, we first calculated the minimum temperatures Tc b required to break a single contact in the MS packing for both single- and multiple-eigenmode perturbations of the T =0 MS packing. We find that the temperature required to break a single contact for equal velocity-amplitude perturbations involving all eigenmodes approaches the minimum value obtained for a perturbation in the direction connecting disk pairs with the smallest overlap. We then studied deviations in the constant volume specific heat C¯V and deviations of the average disk positions Δ r from their T =0 values in the temperature regime TC ¯V
Impact of measurable physical phenomena on contact thermal comfort
NASA Astrophysics Data System (ADS)
Fojtlín, Miloš; Pokorný, Jan; Fišer, Jan; Toma, Róbert; Tuhovčák, Ján
Cabin HVAC (Heating Ventilation and Air-conditioning) systems have become an essential part of personal vehicles as demands for comfortable transport are still rising. In fact, 85 % of the car trips in Europe are shorter than 18 km and last only up to 30 minutes. Under such conditions, the HVAC unit cannot often ensure desired cabin environment and passengers are prone to experience thermal stress. For this reason, additional comfort systems, such as heated or ventilated seats, are available on the market. However, there is no straightforward method to evaluate thermal comfort at the contact surfaces nowadays. The aim of this work is to summarise information about heated and ventilated seats. These technologies use electrical heating and fan driven air to contact area in order to achieve enhanced comfort. It is also expected, that such measures may contribute to lower energy consumption. Yet, in real conditions it is almost impossible to measure the airflow through the ventilated seat directly. Therefore, there is a need for an approach that would correlate measurable physical phenomena with thermal comfort. For this reason, a method that exploits a measurement of temperatures and humidity at the contact area is proposed. Preliminary results that correlate comfort with measurable physical phenomena are demonstrated.
Applicability of Thermal Storage Systems to Air Force Facilities
1990-09-01
Analisis of Region 6 Upper Limit Retrofit Scenario 30% Reduction .... ............. 4.52 4.58 Economic Analysis of Region 7 Upper Limit Retrofit Scenario...or a dynamic-direct contact type. They usually include all the controls, chilling and storage equipment in one self-contained, skid mounted, factory ...SCS technology. One promising trend in reducing system construction costs is the factory -packaged thermal storage cooling unit. As of February 1989
Characterization of Contact and Bulk Thermal Resistance of Laminations for Electric Machines
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cousineau, Emily; Bennion, Kevin; Devoto, Douglas
Thermal management for electric motors is important as the automotive industry continues to transition to more electrically dominant vehicle propulsion systems. The transition to more electrically dominant propulsion systems leads to higher-power duty cycles for electric-drive systems. Thermal constraints place significant limitations on how electric motors ultimately perform. As thermal management improves, there will be a direct trade-off among motor performance, efficiency, cost, and the sizing of electric motors to operate within the thermal constraints. During the development of thermal finite element analysis models and computational fluid dynamics models for electric motors, it was found that there was a lackmore » of open literature detailing the thermal properties of key materials common in electric motors that are significant in terms of heat removal. The lack of available literature, coupled with the strong interest from industry in the passive-stack thermal measurement results, led to experiments to characterize the thermal contact resistance between motor laminations. We examined four lamination materials, including the commonly used 26 gauge and 29 gauge M19 materials, the HF10 and Arnon 7 materials. These latter two materials are thinner and reduce eddy currents responsible for core losses. We measured the thermal conductivity of the lamination materials and the thermal contact resistance between laminations in a stack, as well as investigated factors affecting contact resistance between laminations such as the contact pressure and surface finish. Lamination property data will be provided and we also develop a model to estimate the through-stack thermal conductivity for materials beyond those that were directly tested in this work. For example, at a clamping pressure of 138 kPa, the 29 gauge M19 material has a through-stack thermal conductivity of 1.68 W/m-K, and the contact resistance between laminations was measured to be 193 mm^2-K/W. The measured bulk thermal conductivity for the M19 29 gauge material is 21.0 W/m-K. Density and specific heat were measured to be 7450 kg/m^3 and 463 J/kg-K, respectively. These results are helping, and will continue to help engineers and researchers in the design and development of motors.« less
Ueda, F; Suzuki, M; Fujinaga, Y; Kadoya, M; Takashima, T
1999-09-01
The purpose of this study was to review the normal in vivo neurovascular relationship between the trigeminal nerve and surrounding arteries without the use of volunteers. 290 nerves in 145 cases were reviewed during a 1-year period. Axial source images and multiplanar reconstructed (MPR) images were used to determine the neurovascular contact and direction of contact. Multiplanar volume reformation (MPVR) was used to identify the contact vessels and to demonstrate the relationship between the nerve and arteries. Vascular contact was found in 29% of the 290 nerves (83 nerves). The arteries involved were the superior cerebellar artery (SCA) or the anterior inferior cerebellar artery (AICA). Vascular contact with two arteries was found in 3%. Of the 286 asymptomatic nerves, the nerve was located between the two vessels in 3% and compression was seen in 1%. Three points of vascular contact by the two arteries were identified in one asymptomatic nerve. The direction of contact between the SCA and the nerve was superior (38%), superomedial (32%) or medial (15%) in most cases. The direction of contact between the AICA and the nerve was inferior, inferolateral or lateral in all cases. Vascular contact at the root entry zone (REZ) was noted in 90%. Four nerves were affected by trigeminal neuralgia, one of which touched an artery and two were compressed. It was concluded that arterial contact can be assessed without difficulty but evaluation of vascular compression is not easy.
Kuchin, I; Starov, V
2015-05-19
A theory of contact angle hysteresis of liquid droplets on smooth, homogeneous solid substrates is developed in terms of the shape of the disjoining/conjoining pressure isotherm and quasi-equilibrium phenomena. It is shown that all contact angles, θ, in the range θr < θ < θa, which are different from the unique equilibrium contact angle θ ≠ θe, correspond to the state of slow "microscopic" advancing or receding motion of the liquid if θe < θ < θa or θr < θ < θe, respectively. This "microscopic" motion almost abruptly becomes fast "macroscopic" advancing or receding motion after the contact angle reaches the critical values θa or θr, correspondingly. The values of the static receding, θr, and static advancing, θa, contact angles in cylindrical capillaries were calculated earlier, based on the shape of disjoining/conjoining pressure isotherm. It is shown now that (i) both advancing and receding contact angles of a droplet on a on smooth, homogeneous solid substrate can be calculated based on shape of disjoining/conjoining pressure isotherm, and (ii) both advancing and receding contact angles depend on the drop volume and are not unique characteristics of the liquid-solid system. The latter is different from advancing/receding contact angles in thin capillaries. It is shown also that the receding contact angle is much closer to the equilibrium contact angle than the advancing contact angle. The latter conclusion is unexpected and is in a contradiction with the commonly accepted view that the advancing contact angle can be taken as the first approximation for the equilibrium contact angle. The dependency of hysteresis contact angles on the drop volume has a direct experimental confirmation.
Piezoviscosity In Lubrication Of Nonconformal Contacts
NASA Technical Reports Server (NTRS)
Jeng, Yeau-Ren; Hamrock, Bernard J.; Brewe, David E.
1988-01-01
Developments in theory of lubrication. Analysis of piezoviscous-rigid regime of lubrication of two ellipsoidal contacts. Begins with Reynolds equation for point contact. Equation nondimensionalized using Roelands empirical formula and Dowson and Higginson formula. Equation solved numerically. Solutions obtained for full spectrum of conditions to find effects of dimensionless load, speed, parameters of lubricated and lubricating materials, and angle between direction of rolling and direction of entrainment of lubricant.
PDGF-A suppresses contact inhibition during directional collective cell migration.
Nagel, Martina; Winklbauer, Rudolf
2018-06-08
The leading edge mesendoderm (LEM) of the Xenopus gastrula moves as an aggregate by collective migration. However, LEM cells on fibronectin in vitro show contact inhibition of locomotion by quickly retracting lamellipodia upon mutual contact. We found that a fibronectin-integrin-syndecan module acts between p21-activated kinase-1 upstream and ephrinB1 downstream to promote the contact-induced collapse of lamellipodia. To function in this module, fibronectin has to be present as puncta on the surface of LEM cells. To overcome contact inhibition in LEM cell aggregates, PDGF-A deposited in the endogenous substratum of LEM migration blocks the fibronectin-integrin-syndecan module at the integrin level. This stabilizes lamellipodia preferentially in the direction of normal LEM movement and supports cell orientation and the directional migration of the coherent LEM cell mass. © 2018. Published by The Company of Biologists Ltd.
A Non-Contact Measurement System for the Range of Motion of the Hand
Pham, Trieu; Pathirana, Pubudu N.; Trinh, Hieu; Fay, Pearse
2015-01-01
An accurate and standardised tool to measure the active range of motion (ROM) of the hand is essential to any progressive assessment scenario in hand therapy practice. Goniometers are widely used in clinical settings for measuring the ROM of the hand. However, such measurements have limitations with regard to inter-rater and intra-rater reliability and involve direct physical contact with the hand, possibly increasing the risk of transmitting infections. The system proposed in this paper is the first non-contact measurement system utilising Intel Perceptual Technology and a Senz3D Camera for measuring phalangeal joint angles. To enhance the accuracy of the system, we developed a new approach to achieve the total active movement without measuring three joint angles individually. An equation between the actual spacial position and measurement value of the proximal inter-phalangeal joint was established through the measurement values of the total active movement, so that its actual position can be inferred. Verified by computer simulations, experimental results demonstrated a significant improvement in the calculation of the total active movement and successfully recovered the actual position of the proximal inter-phalangeal joint angles. A trial that was conducted to examine the clinical applicability of the system involving 40 healthy subjects confirmed the practicability and consistency in the proposed system. The time efficiency conveyed a stronger argument for this system to replace the current practice of using goniometers. PMID:26225976
Loison-Robert, Ludwig Stanislas; Berbar, Tsouria; Isaac, Juliane; Berdal, Ariane; Simon, Stéphane
2018-01-01
Background Calcium silicate-based cements are biomaterials with calcium oxide and carbonate filler additives. Their properties are close to those of dentin, making them useful in restorative dentistry and endodontics. The aim of this study was to evaluate the in vitro biological effects of two such calcium silicate cements, Biodentine (BD) and Bioroot (BR), on dental stem cells in both direct and indirect contact models. The two models used aimed to mimic reparative dentin formation (direct contact) and reactionary dentin formation (indirect contact). An original aspect of this study is the use of an interposed thin agarose gel layer to assess the effects of diffusible components from the materials. Results The two biomaterials were compared and did not modify dental pulp stem cell (DPSC) proliferation. BD and BR showed no significant cytotoxicity, although some cell death occurred in direct contact. No apoptosis or inflammation induction was detected. A striking increase of mineralization induction was observed in the presence of BD and BR, and this effect was greater in direct contact. Surprisingly, biomineralization occurred even in the absence of mineralization medium. This differentiation was accompanied by expression of odontoblast-associated genes. Exposure by indirect contact did not stimulate the induction to such a level. Conclusion These two biomaterials both seem to be bioactive and biocompatible, preserving DPSC proliferation, migration and adhesion. The observed strong mineralization induction through direct contact highlights the potential of these biomaterials for clinical application in dentin-pulp complex regeneration. PMID:29370163
Transformative Community School Practices and Impacts: A Tale of Two Community Schools
ERIC Educational Resources Information Center
Aman, Aixle D.
2017-01-01
Students are coming to school with myriad issues that teachers and schools cannot address alone. Ecological systems theory posits that the environments with which a child comes into contact, either directly or indirectly, can impact her or his development (Bronfenbrenner, 1979). With the support of community partner organizations in the local…
77 FR 63712 - Airworthiness Directives; Piaggio Aero Industries S.p.A.
Federal Register 2010, 2011, 2012, 2013, 2014
2012-10-17
... authority for Italy. We issued that AD to prevent the brake hydraulic fluid from leaking because of the brake assembly rods contacting the brake valve tubing, which could result in the inability to adequately... brake pads between pilot and copilot, a brake system rod was found deflected. The rod, in this bent...
ERIC Educational Resources Information Center
Xu, Zhichang
2017-01-01
The internationalization of higher education has brought students from different countries into direct contact with one another. One of the scenarios is intercultural communication among international students in an online environment mediated through institutional e-learning systems, for example, Moodle and Blackboard. In this paper, I analyze…
78 FR 53080 - Airworthiness Directives; Bombardier, Inc. Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2013-08-28
...-102, -103, -106, -201, -202, -301, -311, and -315 series airplanes. This proposed AD was prompted by a... information identified in this proposed AD, contact Bombardier, Inc., Q-Series Technical Help Desk, 123... Series 100 Temporary Revision MRB-153, dated July 10, 2012, Part 1 Section 2-Systems, of the de Havilland...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-05-02
... Ave. SW., Washington, DC 20201. Attention: HIV Open Data Project. FOR FURTHER INFORMATION CONTACT... Open Government Directive,\\2\\ which seeks to improve access to government data in a manner that... advances the DHHS Open Government Plan. The HIV Open Data Project envisioned might offer several benefits...
The Police Response to Mental Illness on Campus
ERIC Educational Resources Information Center
Margolis, Gary J.; Shtull, Penny R.
2012-01-01
Campus police officers are often among the initial contacts for behavioral incidents involving people with mental illness. Their training and access to resources influence decisions to direct the individual to support services and/or through campus disciplinary processes and/or the criminal justice system. Over the past decade, there has been an…
Future networking and cooperation summary of discussion
Roger R. Bay
1993-01-01
At the end of the workshop, I led a lightly structured and informal discussion concerning methods of continuing and improving communications and cooperation among workshop participants. The group specifically ad-dressed three areas: maintaining informal one-on-one direct contacts, improving the use of the ADAP computer system for mail, and the desirability of starting...
Possible Existence of Extra-Terrestrial Technology in the Solar System
NASA Astrophysics Data System (ADS)
Burke-Ward, R.
Potential features of the design and function of extra-terrestrial probes are discussed with the aim of establishing criteria for search, detection and contact. Probes are categorised according to three primary areas of function - data-gathering, direct action, and sentient entities. Conclusions are drawn about possible probe technologies and modes of behaviour.
48 CFR 752.7018 - Health and accident coverage for USAID participant trainees.
Code of Federal Regulations, 2011 CFR
2011-10-01
... Directive System (ADS) 253.5.6b, the Contractor shall enroll all non-U.S. trainees (hereinafter referred to... information regarding each HAC program contractor, including contact information, and a supply of the PDF... participating in a training program financed by USAID, and that enrollment continues in full force and effect...
48 CFR 752.7018 - Health and accident coverage for USAID participant trainees.
Code of Federal Regulations, 2013 CFR
2013-10-01
... Directive System (ADS) 253.5.6b, the Contractor shall enroll all non-U.S. trainees (hereinafter referred to... information regarding each HAC program contractor, including contact information, and a supply of the PDF... participating in a training program financed by USAID, and that enrollment continues in full force and effect...
48 CFR 752.7018 - Health and accident coverage for USAID participant trainees.
Code of Federal Regulations, 2012 CFR
2012-10-01
... Directive System (ADS) 253.5.6b, the Contractor shall enroll all non-U.S. trainees (hereinafter referred to... information regarding each HAC program contractor, including contact information, and a supply of the PDF... participating in a training program financed by USAID, and that enrollment continues in full force and effect...
48 CFR 752.7018 - Health and accident coverage for USAID participant trainees.
Code of Federal Regulations, 2014 CFR
2014-10-01
... Directive System (ADS) 253.5.6b, the Contractor shall enroll all non-U.S. trainees (hereinafter referred to... information regarding each HAC program contractor, including contact information, and a supply of the PDF... participating in a training program financed by USAID, and that enrollment continues in full force and effect...
ERIC Educational Resources Information Center
Gordon, Douglas
2010-01-01
Maintaining student health, safety, and welfare is a primary goal for any K-12 school system. If a child becomes sick, is injured, or seems in any other way incapacitated at school, it is the understood responsibility that the school will provide care and, if necessary, contact the parents and direct the child to outside treatment. Beyond that…
Direct observation of ballistic Andreev reflection
DOE Office of Scientific and Technical Information (OSTI.GOV)
Klapwijk, T. M., E-mail: t.m.klapwijk@tudelft.nl; Ryabchun, S. A.
2014-12-15
An overview is presented of experiments on ballistic electrical transport in inhomogeneous superconducting systems which are controlled by the process of Andreev reflection. The initial experiments based on the coexistence of a normal phase and a superconducting phase in the intermediate state led to the concept itself. It was followed by a focus on geometrically inhomogeneous systems like point contacts, which provided a very clear manifestation of the energy and direction dependence of the Andreev reflection process. The point contacts have recently evolved towards the atomic scale owing to the use of mechanical break-junctions, revealing a very detailed dependence ofmore » Andreev reflection on the macroscopic phase of the superconducting state. In present-day research, the superconducting in homogeneity is constructed by clean room technology and combines superconducting materials, for example, with low-dimensional materials and topological insulators. Alternatively, the superconductor is combined with nano-objects, such as graphene, carbon nanotubes, or semiconducting nanowires. Each of these “inhomogeneous systems” provides a very interesting range of properties, all rooted in some manifestation of Andreev reflection.« less
Complete 360° circumferential SSOCT gonioscopy of the iridocorneal angle
NASA Astrophysics Data System (ADS)
McNabb, Ryan P.; Kuo, Anthony N.; Izatt, Joseph A.
2014-02-01
The ocular iridocorneal angle is generally an optically inaccessible area when viewed directly through the cornea due to the high angle of incidence required and the large index of refraction difference between air and cornea (nair = 1.000 and ncornea = 1.376) resulting in total internal reflection. Gonioscopy allows for viewing of the angle by removing the aircornea interface through the use of a special contact lens on the eye. Gonioscopy is used clinically to visualize the angle directly but only en face. Optical coherence tomography (OCT) has been used to image the angle and deeper structures via an external approach. Typically, this imaging technique is performed by utilizing a conventional anterior segment OCT scanning system. However, instead of imaging the apex of the cornea, either the scanner or the subject is tilted such that the corneoscleral limbus is orthogonal to the optical axis of the scanner requiring multiple volumes to obtain complete circumferential coverage of the ocular angle. We developed a novel gonioscopic OCT (GOCT) system that images the entire ocular angle within a single volume via an "internal" approach through the use of a custom radially symmetric gonioscopic contact lens. We present, to our knowledge, the first complete 360° circumferential volumes of the iridocorneal angle from a direct, internal approach.
Contact with turf algae alters the coral microbiome: contact versus systemic impacts
NASA Astrophysics Data System (ADS)
Pratte, Zoe A.; Longo, Guilherme O.; Burns, Andrew S.; Hay, Mark E.; Stewart, Frank J.
2018-03-01
Coral reefs are degrading to algae-dominated reefs worldwide, with alterations of coral microbiomes commonly co-occurring with reef demise. The severe thermal anomaly during the 2016 El Niño event in the South Pacific killed many corals and stressed others. We examined the microbiome of turf algae and of the coral Porites sp. in contact with turf during this thermal event to investigate algal turf effects on the coral microbiome during a period of environmental stress. The microbial composition of turf did not differ between coral-contacted and non-contacted turfs. However, microbiomes of corals in direct contact with turf were similar to those of the turf microbiome, but differed significantly from coral portions 5 cm from the point of turf/coral contact and from portions of the coral that looked most healthy, regardless of location. Although the majority of significant differences occurred in coral samples at the point of contact, a small subset of microbial taxa was enriched in coral tissues taken 5 cm from turf contact compared to all other sample types, including samples from areas of the coral that appeared most healthy. These results suggest that the coral microbiome is susceptible to colonization by microbes from turf, but not vice versa. Results also suggest that algal contact elicits a subtle shift in the coral microbiome just beyond the contact site. The combination of turf microbiome stability and coral microbiome vulnerability at areas of contact may contribute to the continued decline in coral cover and increase in algal cover associated with coral-algae phase shifts.
Richter, Lars; Bruder, Ralf
2013-05-01
Most medical robotic systems require direct interaction or contact with the robot. Force-Torque (FT) sensors can easily be mounted to the robot to control the contact pressure. However, evaluation is often done in software, which leads to latencies. To overcome that, we developed an independent safety system, named FTA sensor, which is based on an FT sensor and an accelerometer. An embedded system (ES) runs a real-time monitoring system for continuously checking of the readings. In case of a collision or error, it instantaneously stops the robot via the robot's external emergency stop. We found that the ES implementing the FTA sensor has a maximum latency of [Formula: see text] ms to trigger the robot's emergency stop. For the standard settings in the application of robotized transcranial magnetic stimulation, the robot will stop after at most 4 mm. Therefore, it works as an independent safety layer preventing patient and/or operator from serious harm.
Oxy-fuel combustion with integrated pollution control
Patrick, Brian R [Chicago, IL; Ochs, Thomas Lilburn [Albany, OR; Summers, Cathy Ann [Albany, OR; Oryshchyn, Danylo B [Philomath, OR; Turner, Paul Chandler [Independence, OR
2012-01-03
An oxygen fueled integrated pollutant removal and combustion system includes a combustion system and an integrated pollutant removal system. The combustion system includes a furnace having at least one burner that is configured to substantially prevent the introduction of air. An oxygen supply supplies oxygen at a predetermine purity greater than 21 percent and a carbon based fuel supply supplies a carbon based fuel. Oxygen and fuel are fed into the furnace in controlled proportion to each other and combustion is controlled to produce a flame temperature in excess of 3000 degrees F. and a flue gas stream containing CO2 and other gases. The flue gas stream is substantially void of non-fuel borne nitrogen containing combustion produced gaseous compounds. The integrated pollutant removal system includes at least one direct contact heat exchanger for bringing the flue gas into intimated contact with a cooling liquid to produce a pollutant-laden liquid stream and a stripped flue gas stream and at least one compressor for receiving and compressing the stripped flue gas stream.
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
This report summarizes geothermal technical assistance, R&D, and technology transfer activities of the Geo-Heat Center. It describes 95 contacts with parties during this period related to technical assistance with goethermal direct heat projects. Areas dealt with include geothermal heat pumps, space heating, greenhouses, aquaculture, equipment, economics, and resources. Research activities are summarized on geothermal district heating system cost evaluation and silica waste utilization project. Outreach activities include publication of a geothermal direct use Bulletin, dissemination of information, goethermal library, technical papers and seminars, and progress monitor reports on geothermal resources and utilization.
Waldén, Markus; Krosshaug, Tron; Bjørneboe, John; Andersen, Thor Einar; Faul, Oliver
2015-01-01
Background Current knowledge on anterior cruciate ligament (ACL) injury mechanisms in male football players is limited. Aim To describe ACL injury mechanisms in male professional football players using systematic video analysis. Methods We assessed videos from 39 complete ACL tears recorded via prospective professional football injury surveillance between 2001 and 2011. Five analysts independently reviewed all videos to estimate the time of initial foot contact with the ground and the time of ACL tear. We then analysed all videos according to a structured format describing the injury circumstances and lower limb joint biomechanics. Results Twenty-five injuries were non-contact, eight indirect contact and six direct contact injuries. We identified three main categories of non-contact and indirect contact injury situations: (1) pressing (n=11), (2) re-gaining balance after kicking (n=5) and (3) landing after heading (n=5). The fourth main injury situation was direct contact with the injured leg or knee (n=6). Knee valgus was frequently seen in the main categories of non-contact and indirect contact playing situations (n=11), but a dynamic valgus collapse was infrequent (n=3). This was in contrast to the tackling-induced direct contact situations where a knee valgus collapse occurred in all cases (n=3). Conclusions Eighty-five per cent of the ACL injuries in male professional football players resulted from non-contact or indirect contact mechanisms. The most common playing situation leading to injury was pressing followed by kicking and heading. Knee valgus was frequently seen regardless of the playing situation, but a dynamic valgus collapse was rare. PMID:25907183
Laser measurement of respiration activity in preterm infants: Monitoring of peculiar events
NASA Astrophysics Data System (ADS)
Scalise, L.; Marchionni, P.; Ercoli, I.; Tomasini, E. P.
2012-09-01
The Neonatal Intensive Care Unit (NICU) is a part of a pediatric hospital dedicated to the care of ill or pre-term patients . NICU's patients are underweight and most of the time they need cardiac and respiratory support therapies; they are placed in incubators or in cribs maintaining target environmental and body temperatures and protecting patients from bacteria and virus. Patients are continuously monitored for long period of time (days or weeks) due to their possible several health conditions. the most common vital signs monitored are: respiration rate, heart rate, body temperature, blood saturation, etc. Most of the devices used for transducing such quantities in electronic signals - like spirometer or electrocardiogram (ECG) - are in direct contact with the patient and results, also in consideration of the specific patient, largely invasive. In this paper, we propose a novel measurement system for non-contact and non-invasive assessment of the respiration activity, with particular reference to the detection of peculiar respiration events of extreme interest in intensive care units, such as: irregular inspiration/expiration acts, hiccups and apneas. The sensing device proposed is the Laser Doppler Vibrometer (LDVi) which is an non contact, optical measurement system for the assessment of a surface velocity and displacement. In the past it has been demonstrated to be suitable to measure heart rate (HR) and respiration rate (RR) in adult and in preterm infant trough chest-wall displacements. The measurement system is composed by a LDVi system and a data acquisition board installed on a PC, with no direct contact with the patient. Tests have been conducted on 20 NICU patients, for a total of 7219 data sampled. Results show very high correlation (R=0.99) with the reference instrument used for the patient monitoring (mechanical ventilator), with an uncertainty < ±7 ms (k=2). Moreover, during the tests, some peculiar respiration events, have been recorded on 6 of the monitored patients: irregular inspiration/expiration acts (4), hiccups (1) and apneas (1). The proposed measurement method shows to be able to precisely detect the instantaneous respiration frequency of the patient, avoiding patient contact. Moreover the signal collected allow to identify irregularities in the patient respiration of different severity, allowing an optimized action of the care givers.
Contact angle change during evaporation of near-critical liquids
NASA Astrophysics Data System (ADS)
Nikolayev, Vadim; Hegseth, John; Beysens, Daniel
1998-11-01
An unexpected change of the dynamic contact angle was recently observed in a near-critical liquid-gas system in a space experiment. While the near-critical liquid completely wets a solid under equilibrium conditions, the apparent contact angle changed from 0^circ to about 120^circ during evaporation. We propose an explanation for this phenomenon by taking into account vapor recoil due to evaporation (motion of the vapor from the free liquid surface). This force is normal to the vapor-liquid interface and is directed towards the liquid. It increases sharply near the triple contact line. Near the critical point, where the surface tension force is very weak, the vapor recoil force can be important enough to change the apparent contact angle. A similar effect can also explain the drying of a heater during boiling at high heat flux. The drying greatly reduces the heat transfer to the liquid causing the heater to melt. This phenomenon is called ``boiling crisis", ``burnout" or ``Departure from Nuclear Boiling". We report the preliminary results of the numerical simulation of the liquid evaporation by the Boundary Element method.
Segura, J M; Castells, X; Casamitjana, M; Macià, F; Porta, M; Katz, S J
2001-10-01
The objective of this study was to compare the response received by a population-based breast cancer screening program, according to three different invitation strategies: letters sent by mail from the program (program group), letters sent by mail from the Primary Health Care Team (PHT group), and direct contact through a trained professional (direct contact group). We used a cluster-randomized controlled trial with assignment to invitation group using home address. Nine hundred eighty-six women of Barcelona (Spain), ages 50 to 64 years, were invited to participate in the program. The main outcome used was the response rate after the first invitation. Five hundred sixty-four women accepted the invitation (57.2%). The highest response rate was achieved in the direct contact group (63.5%), followed by the PHT group (55.6%), the program group being the one that attained the lowest response rate (52.1%). The direct contact group had a higher probability of participating than the PHT group (RR = 1.14, P = 0.037) or the program group (RR = 1.22, P = 0.003). The response rate in the direct contact group was 72.1% when the letter was received by the subject herself. The increase in response occurred particularly among women of lower educational level. Inviting women to participate in a breast cancer screening program through direct contact by trained personnel increased participation rate compared with mailed-letter methods. The positive effect appeared restricted to women with lower educational levels. Copyright 2001 American Health Foundation and Academic Press.
The architecture of Newton, a general-purpose dynamics simulator
NASA Technical Reports Server (NTRS)
Cremer, James F.; Stewart, A. James
1989-01-01
The architecture for Newton, a general-purpose system for simulating the dynamics of complex physical objects, is described. The system automatically formulates and analyzes equations of motion, and performs automatic modification of this system equations when necessitated by changes in kinematic relationships between objects. Impact and temporary contact are handled, although only using simple models. User-directed influence of simulations is achieved using Newton's module, which can be used to experiment with the control of many-degree-of-freedom articulated objects.
Aquino, Marcella; Rosner, Greg
2018-05-15
Systemic contact dermatitis (SCD) traditionally refers to a skin condition where an individual who is cutaneously sensitized to an allergen will subsequently react to that same allergen or a cross reacting allergen via a different route. It occurs to allergens including metals, medications, and foods. The exact pathophysiology underlying this disease remains unknown, although it appears to be mediated by type 4 hypersensitivity reactions and possibly type 3 hypersensitivity reactions. The p-I concept (pharmacologic interaction with immunoreceptors) hypothesized that drugs are able to bind directly to a T cell receptor without first being presented by MHC (major histocompatibility complex) molecules and without prior metabolism, which would help explain why SCD can be seen on first exposure to medications. Nomenclature remains a challenge as SCD can be subcategorized using terms such as ACDS (allergic contact dermatitis syndrome) and its four clinical stages, Baboon syndrome, and SDRIFE (symmetrical drug-related intertriginous and flexural exanthema), which share many overlapping features. Food allergens may be responsible for uncontrolled or persistent symptoms in patients with contact dermatitis who do not respond to topical avoidance. With medications, symptoms may be induced by topical application versus systemic administration. Patch testing (PT) may be beneficial in diagnosing SCD caused by metals and many topical medications including corticosteroids, antimicrobials (ampicillin, bacitracin, erythromycin, neomycin, nystatin), NSAIDs (diclofenac, ibuprofen), anesthetics, and antihistamines (chlorphenamine, piperazine). Current treatment options include topical steroids and oral antihistamines for symptom relief and dietary avoidance to causative foods or metals.
NASA Astrophysics Data System (ADS)
Fleckenstein, C.; Ziani, N. Traverso; Trauzettel, B.
2018-04-01
Topological superconductors give rise to unconventional superconductivity, which is mainly characterized by the symmetry of the superconducting pairing amplitude. However, since the symmetry of the superconducting pairing amplitude is not directly observable, its experimental identification is rather difficult. In our work, we propose a system, composed of a quantum point contact and proximity-induced s -wave superconductivity at the helical edge of a two-dimensional topological insulator, for which we demonstrate the presence of odd-frequency pairing and its intimate connection to unambiguous transport signatures. Notably, our proposal requires no time-reversal symmetry breaking terms. We discover the domination of crossed Andreev reflection over electron cotunneling in a wide range of parameter space, which is a quite unusual transport regime.
Cadherin-11 Mediates Contact Inhibition of Locomotion during Xenopus Neural Crest Cell Migration
Becker, Sarah F. S.; Mayor, Roberto; Kashef, Jubin
2013-01-01
Collective cell migration is an essential feature both in embryonic development and cancer progression. The molecular mechanisms of these coordinated directional cell movements still need to be elucidated. The migration of cranial neural crest (CNC) cells during embryogenesis is an excellent model for collective cell migration in vivo. These highly motile and multipotent cells migrate directionally on defined routes throughout the embryo. Interestingly, local cell-cell interactions seem to be the key force for directionality. CNC cells can change their migration direction by a repulsive cell response called contact inhibition of locomotion (CIL). Cell protrusions collapse upon homotypic cell-cell contact and internal repolarization leads to formation of new protrusions toward cell-free regions. Wnt/PCP signaling was shown to mediate activation of small RhoGTPase RhoA and inhibition of cell protrusions at the contact side. However, the mechanism how a cell recognizes the contact is poorly understood. Here, we demonstrate that Xenopus cadherin-11 (Xcad-11) mediated cell-cell adhesion is necessary in CIL for directional and collective migration of CNC cells. Reduction of Xcad-11 adhesive function resulted in higher invasiveness of CNC due to loss of CIL. Additionally, transplantation analyses revealed that CNC migratory behaviour in vivo is non-directional and incomplete when Xcad-11 adhesive function is impaired. Blocking Wnt/PCP signaling led to similar results underlining the importance of Xcad-11 in the mechanism of CIL and directional migration of CNC. PMID:24392028
Jenke, Dennis; Egert, Thomas; Hendricker, Alan; Castner, James; Feinberg, Tom; Houston, Christopher; Hunt, Desmond G; Lynch, Michael; Nicholas, Kumudini; Norwood, Daniel L; Paskiet, Diane; Ruberto, Michael; Smith, Edward J; Holcomb, Frank; Markovic, Ingrid
2017-01-01
A simulating leaching (migration) study was performed on a model container-closure system relevant to parenteral and ophthalmic drug products. This container-closure system consisted of a linear low-density polyethylene bottle (primary container), a polypropylene cap and an elastomeric cap liner (closure), an adhesive label (labeling), and a foil overpouch (secondary container). The bottles were filled with simulating solvents (aqueous salt/acid mixture at pH 2.5, aqueous buffer at pH 9.5, and 1/1 v/v isopropanol/water), a label was affixed to the filled and capped bottles, the filled bottles were placed into the foil overpouch, and the filled and pouched units were stored either upright or inverted for up to 6 months at 40 °C. After storage, the leaching solutions were tested for leached substances using multiple complementary analytical techniques to address volatile, semi-volatile, and non-volatile organic and inorganic extractables as potential leachables.The leaching data generated supported several conclusions, including that (1) the extractables (leachables) profile revealed by a simulating leaching study can qualitatively be correlated with compositional information for materials of construction, (2) the chemical nature of both the extracting medium and the individual extractables (leachables) can markedly affect the resulting profile, and (3) while direct contact between a drug product and a system's material of construction may exacerbate the leaching of substances from that material by the drug product, direct contact is not a prerequisite for migration and leaching to occur. LAY ABSTRACT: The migration of container-related extractables from a model pharmaceutical container-closure system and into simulated drug product solutions was studied, focusing on circumstances relevant to parenteral and ophthalmic drug products. The model system was constructed specifically to address the migration of extractables from labels applied to the outside of the primary container. The study demonstrated that (1) the extractables that do migrate can be correlated to the composition of the materials used to construct the container-closure systems, (2) the extent of migration is affected by the chemical nature of the simulating solutions and the extractables themselves, and (3) even though labels may not be in direct contact with a contained solution, label-related extractables can accumulate as leachables in those solutions. © PDA, Inc. 2017.
Thakur, Krishna K; Revie, Crawford W; Hurnik, Daniel; Poljak, Zvonimir; Sanchez, Javier
2015-03-01
Porcine reproductive and respiratory syndrome (PRRS), a viral disease of swine, has major economic impacts on the swine industry. The North American Animal Disease Spread Model (NAADSM) is a spatial, stochastic, farm level state-transition modeling framework originally developed to simulate highly contagious and foreign livestock diseases. The objectives of this study were to develop a model to simulate between-farm spread of a homologous strain of PRRS virus in Ontario swine farms via direct (animal movement) and indirect (sharing of trucks between farms) contacts using the NAADSM and to compare the patterns and extent of outbreak under different simulated conditions. A total of 2552 swine farms in Ontario province were allocated to each census division of Ontario and geo-locations of the farms were randomly generated within the agriculture land of each Census Division. Contact rates among different production types were obtained using pig movement information from four regions in Canada. A total of 24 scenarios were developed involving various direct (movement of infected animals) and indirect (pig transportation trucks) contact parameters in combination with alternating the production type of the farm in which the infection was seeded. Outbreaks were simulated for one year with 1000 replications. The median number of farms infected, proportion of farms with multiple outbreaks and time to reach the peak epidemic were used to compare the size, progression and extent of outbreaks. Scenarios involving spread only by direct contact between farms resulted in outbreaks where the median percentage of infected farms ranged from 31.5 to 37% of all farms. In scenarios with both direct and indirect contact, the median percentage of infected farms increased to a range from 41.6 to 48.6%. Furthermore, scenarios with both direct and indirect contact resulted in a 44% increase in median epidemic size when compared to the direct contact scenarios. Incorporation of both animal movements and the sharing of trucks within the model indicated that the effect of direct and indirect contact may be nonlinear on outbreak progression. The increase of 44% in epidemic size when indirect contact, via sharing of trucks, was incorporated into the model highlights the importance of proper biosecurity measures in preventing transmission of the PRRS virus. Simulation of between-farm spread of the PRRS virus in swine farms has highlighted the relative importance of direct and indirect contact and provides important insights regarding the possible patterns and extent of spread of the PRRS virus in a completely susceptible population with herd demographics similar to those found in Ontario, Canada. Copyright © 2015 Elsevier B.V. All rights reserved.
NASA Astrophysics Data System (ADS)
Miura, Sadahiko; Honjo, Hiroaki; Kinoshita, Keizo; Tokutome, Keiichi; Koike, Hiroaki; Ikeda, Shoji; Endoh, Tetsuo; Ohno, Hideo
2015-04-01
Perpendicular-anisotropy magnetic tunnel junctions (MTJs) were prepared on four substrate geometries, i.e., directly on the axis of the bottom electrode contact, directly off the axis of the bottom electrode contact, on the axis of the bottom electrode contact with a polished bottom electrode, and off the axis of the bottom electrode contact with a polished bottom electrode. Electrical shorts were observed for direct on-axis geometry at a certain extent, whereas there were no electrical shorts for the other three geometries. The MR ratio/σR, JC0, and thermal stability factor of the devices for polish on-axis geometry were almost the same as those for polish off-axis geometry. From TEM observations of the polish on-axis device, the interface between the bottom contact and the base electrode was determined to be rough, whereas the MgO barrier layer was determined to be smooth, indicating that the polish process was effective for smooth magnetic tunnel junction fabrication over the bottom contact. MTJs for polish on-axis geometry eliminated the base electrode resistance and increased the magnetoresistance ratio. This technology contributes to the higher density of spin transfer torque magnetic random access memory.
Contact frequency and cognitive health among older adults in Israel.
Schwartz, Ella; Khalaila, Rabia; Litwin, Howard
2018-05-03
The current study set out to examine the links between contact frequency with one's social network and cognitive health in later life. It assessed both direct and indirect pathways and the possible role of ethnicity in the effect of the social network on cognitive function. We used data from adults aged 50 and above, which was collected in Israel as part of the Survey of Ageing, Retirement and Health (SHARE). A moderated mediation analysis was conducted to test the direct and indirect associations between contact frequency and cognitive function, as well as the moderation of these associations by population group. Three population groups were examined - veteran-Jews, Arabs and immigrants from the former Soviet Union. Contact frequency with the close social milieu was found to be directly positively related to cognitive function. The association was also mediated by depressive symptoms, such that frequent contacts were linked to cognitive health via reduced depressive symptoms. This indirect link differed, however, among the three population groups. Contact frequency is important for cognitive health in the second half of life, and it operates both directly and by decreasing depressive symptoms. However, these links are not found among all ethnic groups and may, therefore, depend on the culture and social norms of each group and the meaning attributed to social ties.
Effects of Grip-Force, Contact, and Acceleration Feedback on a Teleoperated Pick-and-Place Task.
Khurshid, Rebecca P; Fitter, Naomi T; Fedalei, Elizabeth A; Kuchenbecker, Katherine J
2017-01-01
The multifaceted human sense of touch is fundamental to direct manipulation, but technical challenges prevent most teleoperation systems from providing even a single modality of haptic feedback, such as force feedback. This paper postulates that ungrounded grip-force, fingertip-contact-and-pressure, and high-frequency acceleration haptic feedback will improve human performance of a teleoperated pick-and-place task. Thirty subjects used a teleoperation system consisting of a haptic device worn on the subject's right hand, a remote PR2 humanoid robot, and a Vicon motion capture system to move an object to a target location. Each subject completed the pick-and-place task 10 times under each of the eight haptic conditions obtained by turning on and off grip-force feedback, contact feedback, and acceleration feedback. To understand how object stiffness affects the utility of the feedback, half of the subjects completed the task with a flexible plastic cup, and the others used a rigid plastic block. The results indicate that the addition of grip-force feedback with gain switching enables subjects to hold both the flexible and rigid objects more stably, and it also allowed subjects who manipulated the rigid block to hold the object more delicately and to better control the motion of the remote robot's hand. Contact feedback improved the ability of subjects who manipulated the flexible cup to move the robot's arm in space, but it deteriorated this ability for subjects who manipulated the rigid block. Contact feedback also caused subjects to hold the flexible cup less stably, but the rigid block more securely. Finally, adding acceleration feedback slightly improved the subject's performance when setting the object down, as originally hypothesized; interestingly, it also allowed subjects to feel vibrations produced by the robot's motion, causing them to be more careful when completing the task. This study supports the utility of grip-force and high-frequency acceleration feedback in teleoperation systems and motivates further improvements to fingertip-contact-and-pressure feedback.
Lewinstein, Israel; Matalon, Shlomo; Slutzkey, Shimshon; Weiss, Ervin I
2005-04-01
Since failure of fixed partial dentures is most frequently caused by caries, it would be advantageous if cements possessed antibacterial properties. The purpose of this study was to evaluate the antibacterial properties of 3 dental cements using the direct-contact test and agar diffusion test. For the direct-contact test, wells (n = 4) of microtiter plates were coated with the tested cements (Harvard cement, Duralon, and Ketac-Cem) while Streptococcus mutans suspension was placed directly on the cements. Bacterial growth was evaluated by a temperature-controlled microplate spectrophotometer. Eight wells of bacteria without the tested cements served as the positive control. Six wells of the tested cement without bacteria served as the negative control. For the agar diffusion test, triplicate specimens of freshly mixed cements were poured into uniform wells (5 mm in diameter) punched in the agar plates inoculated with Streptococcus mutans . After incubation at 37 degrees C for 24 hours, the agar plates were examined for bacterial growth and the diameter of the halo formed in the bacterial lawn was measured. In both tests, each cement was mixed in 2 different powder/liquid ratios. For the direct-contact test, data were initially recorded after 1 hour of incubation. Additional experiments were performed on specimens that were aged for 24 hours, 1 week, 1 month, and 3 months before assessment by either direct-contact test or agar diffusion test. The data were subjected to 1-way ANOVA with the Tukey post hoc test (alpha=.05). Compared with the control group, Duralon and Harvard cements demonstrated antibacterial properties even after 3 months with the direct-contact test (P <.002), while Ketac-Cem exhibited no antibacterial properties. In the agar diffusion test, no antibacterial activity was observed for any of the tested cements. The different powder/liquid ratios had a negligible effect on the antibacterial properties of the tested cements. Within the limitations of this study, Duralon and Harvard cements possessed prolonged antibacterial properties, while Ketac-Cem exhibited no antibacterial activity. The direct-contact test may be a more suitable test than the agar diffusion test to evaluate antibacterial properties of definitive cements.
NASA Astrophysics Data System (ADS)
Gao, Long-yue; Zhou, Wei-qi; Wang, Yuan-bo; Wang, Si-qi; Bai, Chong; Li, Shi-ming; Liu, Bin; Wang, Jun-nan; Cui, Cheng-kun; Li, Yong-liang
2016-05-01
To solve the problems with coronary stent implantation, coronary artery stent surface was directly modified by three-beam laser interference lithography through imitating the water-repellent surface of lotus leaf, and uniform micro-nano structures with the controllable period were fabricated. The morphological properties and contact angle (CA) of the microstructure were measured by scanning electron microscope (SEM) and CA system. The water repellency of stent was also evaluated by the contact and then separation between the water drop and the stent. The results show that the close-packed concave structure with the period of about 12 μm can be fabricated on the stent surface with special parameters (incident angle of 3°, laser energy density of 2.2 J·cm-2 and exposure time of 80 s) by using the three-beam laser at 1 064 nm, and the structure has good water repellency with CA of 120°.
Human-directed social behaviour in dogs shows significant heritability.
Persson, M E; Roth, L S V; Johnsson, M; Wright, D; Jensen, P
2015-04-01
Through domestication and co-evolution with humans, dogs have developed abilities to attract human attention, e.g. in a manner of seeking assistance when faced with a problem solving task. The aims of this study were to investigate within breed variation in human-directed contact seeking in dogs and to estimate its genetic basis. To do this, 498 research beagles, bred and kept under standardized conditions, were tested in an unsolvable problem task. Contact seeking behaviours recorded included both eye contact and physical interactions. Behavioural data was summarized through a principal component analysis, resulting in four components: test interactions, social interactions, eye contact and physical contact. Females scored significantly higher on social interactions and physical contact and age had an effect on eye contact scores. Narrow sense heritabilities (h(2) ) of the two largest components were estimated at 0.32 and 0.23 but were not significant for the last two components. These results show that within the studied dog population, behavioural variation in human-directed social behaviours was sex dependent and that the utilization of eye contact seeking increased with age and experience. Hence, heritability estimates indicate a significant genetic contribution to the variation found in human-directed social interactions, suggesting that social skills in dogs have a genetic basis, but can also be shaped and enhanced through individual experiences. This research gives the opportunity to further investigate the genetics behind dogs' social skills, which could also play a significant part into research on human social disorders such as autism. © 2015 John Wiley & Sons Ltd and International Behavioural and Neural Genetics Society.
Kotani, Manato; Shimono, Kohei; Yoneyama, Toshihiro; Nakako, Tomokazu; Matsumoto, Kenji; Ogi, Yuji; Konoike, Naho; Nakamura, Katsuki; Ikeda, Kazuhito
2017-09-01
Eye tracking systems are used to investigate eyes position and gaze patterns presumed as eye contact in humans. Eye contact is a useful biomarker of social communication and known to be deficient in patients with autism spectrum disorders (ASDs). Interestingly, the same eye tracking systems have been used to directly compare face scanning patterns in some non-human primates to those in human. Thus, eye tracking is expected to be a useful translational technique for investigating not only social attention and visual interest, but also the effects of psychiatric drugs, such as oxytocin, a neuropeptide that regulates social behavior. In this study, we report on a newly established method for eye tracking in common marmosets as unique New World primates that, like humans, use eye contact as a mean of communication. Our investigation was aimed at characterizing these primates face scanning patterns and evaluating the effects of oxytocin on their eye contact behavior. We found that normal common marmosets spend more time viewing the eyes region in common marmoset's picture than the mouth region or a scrambled picture. In oxytocin experiment, the change in eyes/face ratio was significantly greater in the oxytocin group than in the vehicle group. Moreover, oxytocin-induced increase in the change in eyes/face ratio was completely blocked by the oxytocin receptor antagonist L-368,899. These results indicate that eye tracking in common marmosets may be useful for evaluating drug candidates targeting psychiatric conditions, especially ASDs. Copyright © 2017 Elsevier Ltd. All rights reserved.
Effect of direct and indirect contact with mental illness on dangerousness and social distance.
Lee, Minhwa; Seo, Mikyung
2018-03-01
This study is based on the contact hypothesis that contact with mental illness is the most effective anti-stigma strategy. This study aims to analyze which form of contact can most effectively decrease the dangerousness and social distance associated with schizophrenia, depression and alcoholism. In total, 573 Korean adults ( M age = 43.71 years, standard deviation ( SD) = 13.41; 54.1% male, 45.9% female) were surveyed about randomly assigned vignettes of schizophrenia, depression and alcoholism. The participants were questioned on the dangerousness and social distance associated with the assigned vignette, as well as direct and indirect contact experience with the mental illness. Two-way analysis of variance (ANOVA) was used to determine the main effect and interaction effect that the type of mental illness and contact experience have on the two dependent variables (dangerousness and social distance). The findings show that the type of mental illness has a significant main effect on dangerousness and social distance, but contact type only has a significant main effect on social distance. Moreover, the two independent variables (mental illness subtype and contact experience) have an interaction effect on two dependent variables (dangerousness and social distance). Therefore, the anti-stigma effect of contact varies according to the type of mental illness. Our findings suggest that appropriate anti-stigma strategies are required for each type of mental illness. Considering that opportunities for direct contact with persons with mental illness are highly limited, it is necessary to actively utilize indirect contact.
Environmental Assessment of a Central Heating Plant.
1983-02-01
control equipment will be required. One proven system for SO2 control is flue gas desulfurization (FGt). A variety of systems are currently in use on...low sulfur coal, but it could be further reduced by flue gas desulfur - ization. This option, however, entails greater capital and operating costs and an... wet or dry. Wet processes involve contacting the flue gas with aqueous slurries or solutions of absorbents and produce liquid wastes for direct
NASA Astrophysics Data System (ADS)
Wang, M.; Cole, M. O. T.; Keogh, P. S.
2017-11-01
A new approach for the recovery of contact-free levitation of a rotor supported by active magnetic bearings (AMB) is assessed through control strategy design, system modelling and experimental verification. The rotor is considered to make contact with a touchdown bearing (TDB), which may lead to entrapment in a bi-stable nonlinear response. A linear matrix inequality (LMI) based gain-scheduling H∞ control technique is introduced to recover the rotor to a contact-free state. The controller formulation involves a time-varying effective stiffness parameter, which can be evaluated in terms of forces transmitted through the TDB. Rather than measuring these forces directly, an observer is introduced with a model of the base structure to transform base acceleration signals using polytopic coordinates for controller adjustment. Force transmission to the supporting base structure will occur either through an AMB alone without contact, or through the AMB and TDB with contact and this must be accounted for in the observer design. The controller is verified experimentally in terms of (a) non-contact robust stability and vibration suppression performance; (b) control action for contact-free recovery at typical running speeds with various unbalance and TDB misalignment conditions; and (c) coast-down experimental tests. The results demonstrate the effectiveness of the AMB control action whenever it operates within its dynamic load capacity.
Protecting Yourself From Shingles | NIH MedlinePlus the Magazine
... with shingles can spread the disease through direct contact with the rash when the rash is in the blister phase. ... person who has never had chickenpox through direct contact with the rash. The person exposed would develop chickenpox, not shingles. ...
High speed cylindrical roller bearing analysis. SKF computer program CYBEAN. Volume 2: User's manual
NASA Technical Reports Server (NTRS)
Dyba, G. J.; Kleckner, R. J.
1981-01-01
CYBEAN (CYlindrical BEaring ANalysis) was created to detail radially loaded, aligned and misaligned cylindrical roller bearing performance under a variety of operating conditions. Emphasis was placed on detailing the effects of high speed, preload and system thermal coupling. Roller tilt, skew, radial, circumferential and axial displacement as well as flange contact were considered. Variable housing and flexible out-of-round outer ring geometries, and both steady state and time transient temperature calculations were enabled. The complete range of elastohydrodynamic contact considerations, employing full and partial film conditions were treated in the computation of raceway and flange contacts. The practical and correct implementation of CYBEAN is discussed. The capability to execute the program at four different levels of complexity was included. In addition, the program was updated to properly direct roller-to-raceway contact load vectors automatically in those cases where roller or ring profiles have small radii of curvature. Input and output architectures containing guidelines for use and two sample executions are detailed.
Attention to eye contact in the West and East: autonomic responses and evaluative ratings.
Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K
2013-01-01
Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level.
Attention to Eye Contact in the West and East: Autonomic Responses and Evaluative Ratings
Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K.
2013-01-01
Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level. PMID:23516627
Direct measurement of weakly nonequilibrium system entropy is consistent with Gibbs–Shannon form
2017-01-01
Stochastic thermodynamics extends classical thermodynamics to small systems in contact with one or more heat baths. It can account for the effects of thermal fluctuations and describe systems far from thermodynamic equilibrium. A basic assumption is that the expression for Shannon entropy is the appropriate description for the entropy of a nonequilibrium system in such a setting. Here we measure experimentally this function in a system that is in local but not global equilibrium. Our system is a micron-scale colloidal particle in water, in a virtual double-well potential created by a feedback trap. We measure the work to erase a fraction of a bit of information and show that it is bounded by the Shannon entropy for a two-state system. Further, by measuring directly the reversibility of slow protocols, we can distinguish unambiguously between protocols that can and cannot reach the expected thermodynamic bounds. PMID:29073017
Toward the design of a wearable system for contact thermography in telemedicine.
Giansanti, Daniele; Maccioni, Giovanni; Bernhardt, Paola
2009-04-01
Thermal imaging of the skin has been used for several decades for monitoring of temperature distribution of human skin for the detection of thermal abnormalities indicating pathologies (malignancies, inflammation, infection, and vascular, dermatological, and rheumatic disorders). Literature has shown that to detect and monitor the thermal abnormalities related to pathologic conditions, there is a need to extend acquisition over 8, 12, 16, or 24 hours. A wearable device is strongly needed in contact thermography to reach the objective of long-term monitoring of contact thermography, especially in telemedicine applications. A wearable system has been designed and constructed that allows the continuous thermographic monitoring of a skin region at the point of affixation. Measurement allowed by this system is direct and not hampered by the influence of the environment--as with IR thermography--nor by the geometry of skin surface (curvatures, roughness) thanks to the flexible adaptation of the sensing head to the surface. The validation of the system embedded in a pilot preliminary telemedicine application was successful. The next step will be the wide focusing and adaptation to telemedicine clinical applications to assess the response to the chemotherapy and tune the therapy at home of the breast cancer or the response to the inflammation care.
High voltage MOSFET devices and methods of making the devices
DOE Office of Scientific and Technical Information (OSTI.GOV)
Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran
A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+more » region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.« less
High voltage MOSFET devices and methods of making the devices
Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran
2015-12-15
A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.
A comparison of force control algorithms for robots in contact with flexible environments
NASA Technical Reports Server (NTRS)
Wilfinger, Lee S.
1992-01-01
In order to perform useful tasks, the robot end-effector must come into contact with its environment. For such tasks, force feedback is frequently used to control the interaction forces. Control of these forces is complicated by the fact that the flexibility of the environment affects the stability of the force control algorithm. Because of the wide variety of different materials present in everyday environments, it is necessary to gain an understanding of how environmental flexibility affects the stability of force control algorithms. This report presents the theory and experimental results of two force control algorithms: Position Accommodation Control and Direct Force Servoing. The implementation of each of these algorithms on a two-arm robotic test bed located in the Center for Intelligent Robotic Systems for Space Exploration (CIRSSE) is discussed in detail. The behavior of each algorithm when contacting materials of different flexibility is experimentally determined. In addition, several robustness improvements to the Direct Force Servoing algorithm are suggested and experimentally verified. Finally, a qualitative comparison of the force control algorithms is provided, along with a description of a general tuning process for each control method.
Koetje, Bethany D.; Grabowski, Jurek G.
2008-01-01
This paper describes a standardization method that allows injury researchers to directly compare pedestrian hood contact points across a variety of hood sizes and geometries. To standardize hood contact locations a new coordinate system was created at the geometric center of the hood. Standardizing hood contact locations was done by turning each coordinate location into a ratio of the entire length or width of the hood. The standardized pedestrian contact locations could then be compared for various hood sizes. The standardized hood was divided into a three-by-three grid to aggregate contact points into hood regions. Data was obtained from the National Highway Traffic Safety Administration’s Pedestrian Crash Data Study from 1994 to 1998. To understand injury severity with respect to pedestrian hood contact location, the injuries were narrowed to the single most severe Abreviated Injury Scale injury to the pedestrian and hood location at which that injury was sustained. Of the 97 pedestrian/vehicle cases, pedestrians received 270 injuries from 141 unique hood contact locations. After standardization, 36%, 28%, 36% of all contact points were located on the left, center and right side of the hood respectively. Vertically, 26%, 45%, 28% of contacts occurred at the front, middle, and rear regions of the hood respectively. The middle passenger side of the hood contained the most number of AIS 3+ injuries. By using real-world crash data, engineers can make evidence based decisions to decease the severity of pedestrian injuries. PMID:19026236
Periodic Forced Response of Structures Having Three-Dimensional Frictional Constraints
NASA Astrophysics Data System (ADS)
CHEN, J. J.; YANG, B. D.; MENQ, C. H.
2000-01-01
Many mechanical systems have moving components that are mutually constrained through frictional contacts. When subjected to cyclic excitations, a contact interface may undergo constant changes among sticks, slips and separations, which leads to very complex contact kinematics. In this paper, a 3-D friction contact model is employed to predict the periodic forced response of structures having 3-D frictional constraints. Analytical criteria based on this friction contact model are used to determine the transitions among sticks, slips and separations of the friction contact, and subsequently the constrained force which consists of the induced stick-slip friction force on the contact plane and the contact normal load. The resulting constrained force is often a periodic function and can be considered as a feedback force that influences the response of the constrained structures. By using the Multi-Harmonic Balance Method along with Fast Fourier Transform, the constrained force can be integrated with the receptance of the structures so as to calculate the forced response of the constrained structures. It results in a set of non-linear algebraic equations that can be solved iteratively to yield the relative motion as well as the constrained force at the friction contact. This method is used to predict the periodic response of a frictionally constrained 3-d.o.f. oscillator. The predicted results are compared with those of the direct time integration method so as to validate the proposed method. In addition, the effect of super-harmonic components on the resonant response and jump phenomenon is examined.
Federal Register 2010, 2011, 2012, 2013, 2014
2010-05-04
.... FOR FURTHER INFORMATION CONTACT: Philip Kush, Aerospace Engineer, Propulsion Branch, ANM-140L, FAA... ATTN: Philip Kush, Aerospace Engineer, Propulsion Branch, ANM-140L, FAA, Los Angeles ACO, 3960... AD results from fuel system reviews conducted by the manufacturer. We are issuing this AD to prevent...
Sliding vane geometry turbines
Sun, Harold Huimin; Zhang, Jizhong; Hu, Liangjun; Hanna, Dave R
2014-12-30
Various systems and methods are described for a variable geometry turbine. In one example, a turbine nozzle comprises a central axis and a nozzle vane. The nozzle vane includes a stationary vane and a sliding vane. The sliding vane is positioned to slide in a direction substantially tangent to an inner circumference of the turbine nozzle and in contact with the stationary vane.
Federal Register 2010, 2011, 2012, 2013, 2014
2011-08-03
... CONTACT: Alanna Conley or Michael Mitchell of the Stormwater and Nonpoint Source Section, Water Protection... are available at EPA Region 4's stormwater Web site at: http://www.epa.gov/region4/water/permits... Water Act (CWA) directs EPA to develop a phased approach to regulate stormwater discharges under the...
Federal Register 2010, 2011, 2012, 2013, 2014
2011-07-19
... CONTACT: Stephen Styskal, Aerospace Engineer, Cabin Safety and Environmental Systems Branch, ANM-150S, FAA...) 917-6439; fax: (425) 917-6590; e- mail: stephen[email protected] . SUPPLEMENTARY INFORMATION: Comments... Information (h) Actions done before the effective date of this AD in accordance with Boeing Special Attention...
Federal Register 2010, 2011, 2012, 2013, 2014
2010-12-21
...: Investigation of a recent high altitude loss of cabin pressurization on a BD-100-1A10 aircraft determined that... receipt. FOR FURTHER INFORMATION CONTACT: Cesar Gomez, Aerospace Engineer, Airframe and Mechanical Systems... follows from that determination. The MCAI states: Investigation of a recent high altitude loss of cabin...
Persson, Mia E; Trottier, Agaia J; Bélteky, Johan; Roth, Lina S V; Jensen, Per
2017-09-01
The oxytocin system may play an important role in dog domestication from the wolf. Dogs have evolved unique human analogue social skills enabling them to communicate and cooperate efficiently with people. Genomic differences in the region surrounding the oxytocin receptor (OXTR) gene have previously been associated with variation in dogs' communicative skills. Here we have utilized the unsolvable problem paradigm to investigate the effects of oxytocin and OXTR polymorphisms on human-directed contact seeking behavior in 60 golden retriever dogs. Human-oriented behavior was quantified employing a previously defined unsolvable problem paradigm. Behaviors were tested twice in a repeated, counterbalanced design, where dogs received a nasal dose of either oxytocin or saline 45min before each test occasion. Buccal DNA was analysed for genotype on three previously identified SNP-markers associated with OXTR. The same polymorphisms were also genotyped in 21 wolf blood samples to explore potential genomic differences between the species. Results showed that oxytocin treatment decreased physical contact seeking with the experimenter and one of the three polymorphisms was associated with degree of physical contact seeking with the owner. Dogs with the AA-genotype at this locus increased owner physical contact seeking in response to oxytocin while the opposite effect was found in GG-genotype individuals. Hence, intranasal oxytocin treatment, an OXTR polymorphism and their interaction are associated with dogs' human-directed social skills, which can explain previously described breed differences in oxytocin response. Genotypic variation at the studied locus was also found in wolves indicating that it was present even at the start of dog domestication. Copyright © 2017 Elsevier Inc. All rights reserved.
Epitaxially grown collagen fibrils reveal diversity in contact guidance behavior among cancer cells.
Wang, Juan; Petefish, Joseph W; Hillier, Andrew C; Schneider, Ian C
2015-01-01
Invasion of cancer cells into the surrounding tissue is an important step during cancer progression and is driven by cell migration. Cell migration can be random, but often it is directed by various cues such as aligned fibers composed of extracellular matrix (ECM), a process called contact guidance. During contact guidance, aligned fibers bias migration along the long axis of the fibers. These aligned fibers of ECM are commonly composed of type I collagen, an abundant structural protein around tumors. In this paper, we epitaxially grew several different patterns of organized type I collagen on mica and compared the morphology and contact guidance behavior of two invasive breast cancer cell lines (MDA-MB-231 and MTLn3 cells). Others have shown that these cells randomly migrate in qualitatively different ways. MDA-MB-231 cells exert large traction forces, tightly adhere to the ECM, and migrate with spindle-shaped morphology and thus adopt a mesenchymal mode of migration. MTLn3 cells exert small traction forces, loosely adhere to the ECM, and migrate with a more rounded morphology and thus adopt an amoeboid mode of migration. As the degree of alignment of type I collagen fibrils increases, cells become more elongated and engage in more directed contact guidance. MDA-MB-231 cells perceive the directional signal of highly aligned type I collagen fibrils with high fidelity, elongating to large extents and migrating directionally. Interestingly, behavior in MTLn3 cells differs. While highly aligned type I collagen fibril patterns facilitate spreading and random migration of MTLn3 cells, they do not support elongation or directed migration. Thus, different contact guidance cues bias cell migration differently and the fidelity of contact guidance is cell type dependent, suggesting that ECM alignment is a permissive cue for contact guidance, but requires a cell to have certain properties to interpret that cue.
Safety aspects of whole-body cryochamber and cryosauna operation
NASA Astrophysics Data System (ADS)
Agnieszka, Piotrowska
2017-12-01
Interest in low temperature treatment is constantly increasing. Whole-body cryotherapy (WBC) devices are becoming available not only in medical centers but also in local gyms and spa centers. A new group of users are professional sport clubs where 3-minutes session of whole-body cryotherapy is post-training procedure to improve and speed up the recovery process. There are four different types of WBC devices available on the market and offered to commercial (non-medical) users. The American and European market is dominated by two of them: classic cryochambers and cryosaunas. Both constructions are supplied with liquid nitrogen. Low temperature inside classic cryochamber is produced by evaporating of liquid nitrogen in two or more heat exchangers. There is never a direct contact between user and cryogenic medium in any of system operation mode (closed supply system). Cryosauna is cooled down by filling with cold vapor of liquid nitrogen. Supply system is considered open because it allows for direct contact between user and cryogenic medium. Open supply system of cryosauna is primary and most questionable issue of its operational safety, particularly after tragic accident in October 2015. This paper presents the comparative analysis of classic cryochamber and cryosauna from safety point of view. Both devices have been analyzes and tested on existing systems in operation. Paper gives detailed analysis of constructions, supply systems and working parameters. Special attention has been focused to problem of oxygen deficiency hazard. Different failure or accident scenarios have been analyzed and discussed.
Solar Powered Automobile Interior Climate Control System
NASA Technical Reports Server (NTRS)
Howard, Richard T. (Inventor)
2003-01-01
There is provided a climate control system for a parked vehicle that includes a solar panel, thermostatic switch, fans, and thermoelectric coolers. The solar panel can serve as the sole source of electricity for the system. The system affords convenient installation and removal by including solar panels that are removably attached to the exterior of a vehicle. A connecting wire electrically connects the solar panels to a housing that is removably mounted to a partially opened window on the vehicle. The thermostatic switch, fans, and thermoelectric coolers are included within the housing. The thermostatic switch alternates the direction of the current flow through the thermoelectric coolers to selectively heat or cool the interior of the vehicle. The interior surface of the thermoelectric coolers are in contact with interior heat sinks that have air circulated across them by an interior fan. Similarly, the exterior surface of the thermoelectric coolers are in contact with exterior heat sinks that have air circulated across them by an exterior fan.
Clinical measurement of the height of the interproximal contact area in maxillary anterior teeth.
Sghaireen, Mohd G; Al-Zarea, Bader K; Al-Shorman, Hisham M; Al-Omiri, Mahmoud K
2013-11-01
To clinically quantify the apicoincisal height of interproximal areas directly in patients' mouths. Thirty participants (11 females and 9 males, mean age=26±1.5 years) were recruited into this study. Measurement of interproximal contact areas was carried out directly in patients' mouths using digital caliper (TERENSA, USA) with measuring accuracy of 0.01 mm. The interproximal contact areas that were measured are: central incisor to central incisor, central incisor to lateral incisor, lateral incisor to canine, and canine to first premolar on both sides of the jaw. Statistical significance was based on probability values less than 0.05 (p<0.05). The largest contact point was the one present between central incisors and it ranged from 2.9 to 6.5 mm. On the other hand, the contact point between canine and first premolar was the smallest on both sides of the arch and ranged from 0.6 to 2.5 mm. The dimensions of the contact points declined as we move from anterior area backwards. Statistical analysis using t-test showed that there were significant differences between the measurements of interproximal points of each tooth (P<0.05). the apicogingival dimension of the contact point decreased as we moved from anterior to posterior teeth. The contact area between the central incisors was largest and the one between canine and premolar was the smallest. This study is the first to report direct intra-oral clinical measurement of contact points. Clinical evaluation of contact point dimensions using digital caliber is a viable, quick and accurate method to use.
Light transfer through windows with external condensation
NASA Astrophysics Data System (ADS)
Zhu, Keyong; Li, Shaoling; Pilon, Laurent
2018-03-01
This study investigates systematically light transfer through windows supporting cap-shaped droplets on their external face. The presence of such droplets may have negative effects on the conversion efficiency of solar cells, distorts image quality of lenses, or hinders visibility through windows and windshields. Here, the directional-hemispherical transmittance was predicted by the Monte Carlo ray-tracing method. The droplets were monodisperse or polydisperse randomly distributed on the outside face of optically smooth windows. For nonabsorbing droplets, the diameter and size distribution did not have a significant effect on the window directional-hemispherical transmittance. The latter was nearly independent of contact angle for incident angle θi ≤ 30°. However, the directional-hemispherical transmittance decreased monotonously with increasing incident angle and droplet contact angle for contact angle θc ≤ 70° to reach a minimum at a contact angle θc,min beyond which it increased with increasing contact angle before reaching a plateau at large contact angles. This was attributed to total internal reflection at the back window/air and droplet/air interfaces. For absorbing droplets, the normal-hemispherical transmittance decreased significantly with increasing droplet contact angle, mean diameter, polydispersity, and projected surface area coverage due to strong absorption within the droplets. Moreover, the normal-hemispherical transmittance decreased with increasing contact angle for θc< 90° and remained constant and independent of the droplets' absorption index, mean diameter, and contact angle for θc ≥ 90°. Finally, Analytical expressions for the upper and lower bounds of the normal-hemispherical transmittance as a function of droplet contact angle, optical properties, and projected surface area coverage were derived.
Ray, Thomas A; Roy, Suva; Kozlowski, Christopher; Wang, Jingjing; Cafaro, Jon; Hulbert, Samuel W; Wright, Christopher V; Field, Greg D
2018-01-01
A common strategy by which developing neurons locate their synaptic partners is through projections to circuit-specific neuropil sublayers. Once established, sublayers serve as a substrate for selective synapse formation, but how sublayers arise during neurodevelopment remains unknown. Here, we identify the earliest events that initiate formation of the direction-selective circuit in the inner plexiform layer of mouse retina. We demonstrate that radially migrating newborn starburst amacrine cells establish homotypic contacts on arrival at the inner retina. These contacts, mediated by the cell-surface protein MEGF10, trigger neuropil innervation resulting in generation of two sublayers comprising starburst-cell dendrites. This dendritic scaffold then recruits projections from circuit partners. Abolishing MEGF10-mediated contacts profoundly delays and ultimately disrupts sublayer formation, leading to broader direction tuning and weaker direction-selectivity in retinal ganglion cells. Our findings reveal a mechanism by which differentiating neurons transition from migratory to mature morphology, and highlight this mechanism’s importance in forming circuit-specific sublayers. PMID:29611808
An Optical Sensor for Measuring the Position and Slanting Direction of Flat Surfaces
Chen, Yu-Ta; Huang, Yen-Sheng; Liu, Chien-Sheng
2016-01-01
Automated optical inspection is a very important technique. For this reason, this study proposes an optical non-contact slanting surface measuring system. The essential features of the measurement system are obtained through simulations using the optical design software Zemax. The actual propagation of laser beams within the measurement system is traced by using a homogeneous transformation matrix (HTM), the skew-ray tracing method, and a first-order Taylor series expansion. Additionally, a complete mathematical model that describes the variations in light spots on photoelectric sensors and the corresponding changes in the sample orientation and distance was established. Finally, a laboratory prototype system was constructed on an optical bench to verify experimentally the proposed system. This measurement system can simultaneously detect the slanting angles (x, z) in the x and z directions of the sample and the distance (y) between the biconvex lens and the flat sample surface. PMID:27409619
An Optical Sensor for Measuring the Position and Slanting Direction of Flat Surfaces.
Chen, Yu-Ta; Huang, Yen-Sheng; Liu, Chien-Sheng
2016-07-09
Automated optical inspection is a very important technique. For this reason, this study proposes an optical non-contact slanting surface measuring system. The essential features of the measurement system are obtained through simulations using the optical design software Zemax. The actual propagation of laser beams within the measurement system is traced by using a homogeneous transformation matrix (HTM), the skew-ray tracing method, and a first-order Taylor series expansion. Additionally, a complete mathematical model that describes the variations in light spots on photoelectric sensors and the corresponding changes in the sample orientation and distance was established. Finally, a laboratory prototype system was constructed on an optical bench to verify experimentally the proposed system. This measurement system can simultaneously detect the slanting angles (x, z) in the x and z directions of the sample and the distance (y) between the biconvex lens and the flat sample surface.
Sghaireen, Mohd G; Albhiran, Heyam Mobark; Alzoubi, Ibrahim A; Lynch, Edward; Al-Omiri, Mahmoud K
2015-01-01
This study aimed to clinically quantify the apicoincisal height of the upper interproximal areas directly in patients' mouths compared to measurements on stone models. One hundred and fifty participants (75 females and 75 males, age range 20-45 years) were recruited for this study. A digital caliper was used to measure the anterior maxillary interproximal contact areas directly in patients' mouths and on stone models. The digital caliper accuracy was up to 0.01. The Statistical Package for Social Sciences software (SPSS, version 19.0, Chicago, Ill., USA) was used for statistical analysis. Statistical significance was based on probability values <0.05. The intraoral measurement of proximal contacts as well as the measurement on stone models showed that the dimensions of interproximal contacts on both sides of each tooth were significantly different (p < 0.001) and that the dimension of the mesial contact point was larger than that of the distal contact point of each tooth. The largest contact point was the one between the central incisors (direct intraoral measurement = 2.9-6.49 mm; model measurement = 3.31-6.91 mm). On the other hand, the contact point between the canine and first premolar was the smallest on both sides of the arch (0.63-2.52 mm intraorally, 0.98-2.88 mm on models). The intraoral measurement of contact points was more accurate than model measurements, and the differences were statistically significant (p < 0.001). The clinical evaluation of contact point dimensions using a digital caliper was more precise than measuring contact points on stone models; hence, it is a viable, quick and adequate method to be used routinely. © 2015 S. Karger AG, Basel.
Zeighami, A; Aissaoui, R; Dumas, R
2018-03-01
Contact point (CP) trajectory is a crucial parameter in estimating medial/lateral tibio-femoral contact forces from the musculoskeletal (MSK) models. The objective of the present study was to develop a method to incorporate the subject-specific CP trajectories into the MSK model. Ten healthy subjects performed 45 s treadmill gait trials. The subject-specific CP trajectories were constructed on the tibia and femur as a function of extension-flexion using low-dose bi-plane X-ray images during a quasi-static squat. At each extension-flexion position, the tibia and femur CPs were superimposed in the three directions on the medial side, and in the anterior-posterior and proximal-distal directions on the lateral side to form the five kinematic constraints of the knee joint. The Lagrange multipliers associated to these constraints directly yielded the medial/lateral contact forces. The results from the personalized CP trajectory model were compared against the linear CP trajectory and sphere-on-plane CP trajectory models which were adapted from the commonly used MSK models. Changing the CP trajectory had a remarkable impact on the knee kinematics and changed the medial and lateral contact forces by 1.03 BW and 0.65 BW respectively, in certain subjects. The direction and magnitude of the medial/lateral contact force were highly variable among the subjects and the medial-lateral shift of the CPs alone could not determine the increase/decrease pattern of the contact forces. The suggested kinematic constraints are adaptable to the CP trajectories derived from a variety of joint models and those experimentally measured from the 3D imaging techniques. Copyright © 2018 Elsevier Ltd. All rights reserved.
The scaling of contact rates with population density for the infectious disease models.
Hu, Hao; Nigmatulina, Karima; Eckhoff, Philip
2013-08-01
Contact rates and patterns among individuals in a geographic area drive transmission of directly-transmitted pathogens, making it essential to understand and estimate contacts for simulation of disease dynamics. Under the uniform mixing assumption, one of two mechanisms is typically used to describe the relation between contact rate and population density: density-dependent or frequency-dependent. Based on existing evidence of population threshold and human mobility patterns, we formulated a spatial contact model to describe the appropriate form of transmission with initial growth at low density and saturation at higher density. We show that the two mechanisms are extreme cases that do not capture real population movement across all scales. Empirical data of human and wildlife diseases indicate that a nonlinear function may work better when looking at the full spectrum of densities. This estimation can be applied to large areas with population mixing in general activities. For crowds with unusually large densities (e.g., transportation terminals, stadiums, or mass gatherings), the lack of organized social contact structure deviates the physical contacts towards a special case of the spatial contact model - the dynamics of kinetic gas molecule collision. In this case, an ideal gas model with van der Waals correction fits well; existing movement observation data and the contact rate between individuals is estimated using kinetic theory. A complete picture of contact rate scaling with population density may help clarify the definition of transmission rates in heterogeneous, large-scale spatial systems. Copyright © 2013 The Authors. Published by Elsevier Inc. All rights reserved.
Ghosh, Anirban; Baltekin, Özden; Wäneskog, Marcus; Elkhalifa, Dina; Hammarlöf, Disa L; Elf, Johan; Koskiniemi, Sanna
2018-05-02
Bacterial populations can use bet-hedging strategies to cope with rapidly changing environments. One example is non-growing cells in clonal bacterial populations that are able to persist antibiotic treatment. Previous studies suggest that persisters arise in bacterial populations either stochastically through variation in levels of global signalling molecules between individual cells, or in response to various stresses. Here, we show that toxins used in contact-dependent growth inhibition (CDI) create persisters upon direct contact with cells lacking sufficient levels of CdiI immunity protein, which would otherwise bind to and neutralize toxin activity. CDI-mediated persisters form through a feedforward cycle where the toxic activity of the CdiA toxin increases cellular (p)ppGpp levels, which results in Lon-mediated degradation of the immunity protein and more free toxin. Thus, CDI systems mediate a population density-dependent bet-hedging strategy, where the fraction of non-growing cells is increased only when there are many cells of the same genotype. This may be one of the mechanisms of how CDI systems increase the fitness of their hosts. © 2018 The Authors.
2014-04-01
Corneal damage can have a variety of causes, including infections, chemical splashes, environmental factors (radiation, trauma, contact lenses, etc.), and systemic diseases (genetic, autoimmune, inflammatory, metabolic, etc.). A wide range of drugs can also damage the cornea. The severity of drug-induced corneal changes can range from simple asymptomatic deposits to irreversible, sight-threatening damage. Several factors can influence the onset of corneal lesions. Some factors, such as the dose, are treatment-related, while others such as contact lenses, are patient-related. A variety of mechanisms may be involved, including corneal dryness, changes in the corneal epithelium, impaired wound healing and deposits. Many drugs can damage the cornea through direct contact, after intraocular injection or instillation, including VEGF inhibitors, anti-inflammatory drugs, local anaesthetics, glaucoma drugs, fluoroquinolones, and preservatives. Some systemically administered drugs can also damage the cornea, notably cancer drugs, amiodarone and isotretinoin. Vulnerable patients should be informed of this risk if they are prescribed a drug with the potential to damage the cornea so that they can identify problems in a timely manner. It may be necessary to discontinue the suspect drug when signs and symptoms of corneal damage occur.
A 3D contact analysis approach for the visualization of the electrical contact asperities
DOE Office of Scientific and Technical Information (OSTI.GOV)
Roussos, Constantinos C.; Swingler, Jonathan
The electrical contact is an important phenomenon that should be given into consideration to achieve better performance and long term reliability for the design of devices. Based upon this importance, the electrical contact interface has been visualized as a “3D Contact Map” and used in order to investigate the contact asperities. The contact asperities describe the structures above and below the contact spots (the contact spots define the 3D contact map) to the two conductors which make the contact system. The contact asperities require the discretization of the 3D microstructures of the contact system into voxels. A contact analysis approachmore » has been developed and introduced in this paper which shows the way to the 3D visualization of the contact asperities of a given contact system. For the discretization of 3D microstructure of contact system into voxels, X-ray Computed Tomography (CT) method is used in order to collect the data of a 250 V, 16 A rated AC single pole rocker switch which is used as a contact system for investigation.« less
A 3D contact analysis approach for the visualization of the electrical contact asperities
Swingler, Jonathan
2017-01-01
The electrical contact is an important phenomenon that should be given into consideration to achieve better performance and long term reliability for the design of devices. Based upon this importance, the electrical contact interface has been visualized as a ‘‘3D Contact Map’’ and used in order to investigate the contact asperities. The contact asperities describe the structures above and below the contact spots (the contact spots define the 3D contact map) to the two conductors which make the contact system. The contact asperities require the discretization of the 3D microstructures of the contact system into voxels. A contact analysis approach has been developed and introduced in this paper which shows the way to the 3D visualization of the contact asperities of a given contact system. For the discretization of 3D microstructure of contact system into voxels, X-ray Computed Tomography (CT) method is used in order to collect the data of a 250 V, 16 A rated AC single pole rocker switch which is used as a contact system for investigation. PMID:28105383
A 3D contact analysis approach for the visualization of the electrical contact asperities
Roussos, Constantinos C.; Swingler, Jonathan
2017-01-11
The electrical contact is an important phenomenon that should be given into consideration to achieve better performance and long term reliability for the design of devices. Based upon this importance, the electrical contact interface has been visualized as a “3D Contact Map” and used in order to investigate the contact asperities. The contact asperities describe the structures above and below the contact spots (the contact spots define the 3D contact map) to the two conductors which make the contact system. The contact asperities require the discretization of the 3D microstructures of the contact system into voxels. A contact analysis approachmore » has been developed and introduced in this paper which shows the way to the 3D visualization of the contact asperities of a given contact system. For the discretization of 3D microstructure of contact system into voxels, X-ray Computed Tomography (CT) method is used in order to collect the data of a 250 V, 16 A rated AC single pole rocker switch which is used as a contact system for investigation.« less
Equivalent reduced model technique development for nonlinear system dynamic response
NASA Astrophysics Data System (ADS)
Thibault, Louis; Avitabile, Peter; Foley, Jason; Wolfson, Janet
2013-04-01
The dynamic response of structural systems commonly involves nonlinear effects. Often times, structural systems are made up of several components, whose individual behavior is essentially linear compared to the total assembled system. However, the assembly of linear components using highly nonlinear connection elements or contact regions causes the entire system to become nonlinear. Conventional transient nonlinear integration of the equations of motion can be extremely computationally intensive, especially when the finite element models describing the components are very large and detailed. In this work, the equivalent reduced model technique (ERMT) is developed to address complicated nonlinear contact problems. ERMT utilizes a highly accurate model reduction scheme, the System equivalent reduction expansion process (SEREP). Extremely reduced order models that provide dynamic characteristics of linear components, which are interconnected with highly nonlinear connection elements, are formulated with SEREP for the dynamic response evaluation using direct integration techniques. The full-space solution will be compared to the response obtained using drastically reduced models to make evident the usefulness of the technique for a variety of analytical cases.
Length scale selects directionality of droplets on vibrating pillar ratchet
Agapov, Rebecca L.; Boreyko, Jonathan B.; Briggs, Dayrl P.; ...
2014-09-22
Directional control of droplet motion at room temperature is of interest for applications such as microfluidic devices, self-cleaning coatings, and directional adhesives. Here, arrays of tilted pillars ranging in height from the nanoscale to the microscale are used as structural ratchets to directionally transport water at room temperature. Water droplets deposited on vibrating chips with a nanostructured ratchet move preferentially in the direction of the feature tilt while the opposite directionality is observed in the case of microstructured ratchets. This remarkable switch in directionality is consistent with changes in the contact angle hysteresis. To glean further insights into the lengthmore » scale dependent asymmetric contact angle hysteresis, the contact lines formed by a nonvolatile room temperature ionic liquid placed onto the tilted pillar arrays were visualized and analyzed in situ in a scanning electron microscope. As a result, the ability to tune droplet directionality by merely changing the length scale of surface features all etched at the same tilt angle would be a versatile tool for manipulating multiphase flows and for selecting droplet directionality in other lap-on-chip applications.« less
NASA Astrophysics Data System (ADS)
Hu, Yuanyuan; Xu, Yingying; Hao, Qun; Hu, Yao
2013-12-01
The tubing internal thread plays an irreplaceable role in the petroleum equipment. The unqualified tubing can directly lead to leakage, slippage and bring huge losses for oil industry. For the purpose of improving efficiency and precision of tubing internal thread detection, we develop a new non-contact tubing internal thread measurement system based on the laser triangulation principle. Firstly, considering that the tubing thread had a small diameter and relatively smooth surface, we built a set of optical system with a line structured light to irradiate the internal thread surface and obtain an image which contains the internal thread profile information through photoelectric sensor. Secondly, image processing techniques were used to do the edge detection of the internal thread from the obtained image. One key method was the sub-pixel technique which greatly improved the detection accuracy under the same hardware conditions. Finally, we restored the real internal thread contour information on the basis of laser triangulation method and calculated tubing thread parameters such as the pitch, taper and tooth type angle. In this system, the profile of several thread teeth can be obtained at the same time. Compared with other existing scanning methods using point light and stepper motor, this system greatly improves the detection efficiency. Experiment results indicate that this system can achieve the high precision and non-contact measurement of the tubing internal thread.
Stokes flow inside an evaporating liquid line for any contact angle
NASA Astrophysics Data System (ADS)
Petsi, A. J.; Burganos, V. N.
2008-09-01
Evaporation of droplets or liquid films lying on a substrate induces internal viscous flow, which affects the transport of suspended particles and, thus, the final deposit profile in numerous applications. In this work, the problem of Stokes flow inside a two-dimensional droplet, representing the cross section of an evaporating liquid line lying on a flat surface, is considered. The stream function formulation is adopted, leading to the biharmonic equation in bipolar coordinates. A solution in closed form is obtained for any contact angle in (0,π) and is, thus, valid for both hydrophilic and hydrophobic substrates. The solution can be used with any type of evaporation mechanism, including diffusion, convection, or kinetically controlled modes. Both pinned and depinned contact lines are considered. For the boundary conditions to be compatible at the contact lines, the Navier slip boundary condition is applied on the substrate. Numerical results are presented for kinetically and diffusion controlled evaporation. For pinned contact lines, the flow inside the evaporating liquid line is directed towards the edges, thus, promoting the coffee stain phenomenon. In the case of depinned contact lines and contact angle less than π/2 , the flow is directed towards the center of the droplet, whereas, for strongly hydrophobic substrates it is directed outwards.
Remediating Third-Party Software Vulnerabilities on U.S. Army Information Systems
2012-06-01
tended to result in the defacement of websites. Attacks coming from Eastern Europe and Russia were directed primarily at Point of Sale (PoS) systems.55...interrupt the user to ask their permission to install a security update. This method is used by Sun Java, Apple QuickTime/Safari/ iTunes , Adobe Flash...only be obtained by contacting its sales department. Several vendors offered a wide range of useful videos, including Microsoft, LANDesk, CFEngine
Advanced radiator concepts feasibility demonstration
NASA Astrophysics Data System (ADS)
Rhee, Hyop S.; Begg, Lester; Wetch, Joseph R.; Juhasz, Albert J.
1991-01-01
An innovative pumped loop concept for 600 K space power system radiators is under development utilizing direct contact heat transfer, which facilitates repeated startup/shutdown of the power system without complex and time-consuming coolant thawing during power startup. The melting/freezing process of Li in a NaK flow was studied experimentally to demonstrate the Li/NaK radiator feasibility during startup (thawing) and shutdown (cold-trapping). Results of the vapor grown carbon fiber/composite thermal conductivity measurements are also presented.
Advanced radiator concepts feasibility demonstration
NASA Astrophysics Data System (ADS)
Rhee, Hyop S.; Begg, Lester; Wetch, Joseph R.; Juhasz, Albert J.
An innovative pumped loop concept for 600 K space power system radiators is under development utilizing direct contact heat transfer, which facilitates repeated startup/shutdown of the power system without complex and time-consuming coolant thawing during power startup. The melting/freezing process of Li in a NaK flow was studied experimentally to demonstrate the Li/NaK radiator feasibility during startup (thawing) and shutdown (cold-trapping). Results of the vapor grown carbon fiber/composite thermal conductivity measurements are also presented.
Chiba, Akira
2007-02-08
Immunohistochemical and electron microscopic studies were carried out to elucidate the structure of the serotonergic neuron system in the spinal cord of the spotted gar, Lepisosteus oculatus, a nonteleost actinopterygian. Serotonin-immunoreactive (5HT-IR) cell bodies and fibers were widely distributed in the spinal cord, constituting an intrinsic neuron system. This system comprised three anatomical cell groups in different portions of the spinal cord, i.e., the rostromedial cell group, the paired ventrolateral cell groups, and the ventral superficial cell group. The rostromedial cell group included cerebrospinal fluid-contacting neurons with intraventricular processes. The immunostained fibers projecting from all three of these cell groups ran in various directions, mainly ventrally and ventrolaterally, and partly gave rise to a dense plexus at the ventrolateral surface of the spinal cord. Immunoelectron microscopy of the relevant portion demonstrated many varicose fibers containing 5HT-immunopositive vesicles. Conventional electron microscopy of the plexus showed that the constituent varicose fibers were unmyelinated and frequently made a direct contact with the basement membrane contiguous to the leptomeniges (meninx primitiva). There, exocytotic figures of cytoplasmic vesicles were demonstrated, suggesting that 5HT may be secreted, in a paracrine way, into the extraspinal space. This specialized area in the gar spinal cord may be referred to as the juxtameningeal serotonergic plexus.
21 CFR 886.5925 - Soft (hydrophilic) contact lens.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Soft (hydrophilic) contact lens. 886.5925 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5925 Soft (hydrophilic) contact lens. (a) Identification. A soft (hydrophilic) contact lens is a device intended to be worn directly...
21 CFR 886.5925 - Soft (hydrophilic) contact lens.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Soft (hydrophilic) contact lens. 886.5925 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5925 Soft (hydrophilic) contact lens. (a) Identification. A soft (hydrophilic) contact lens is a device intended to be worn directly...
37 CFR 10.33 - Direct contact with prospective clients.
Code of Federal Regulations, 2010 CFR
2010-07-01
... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Direct contact with prospective clients. 10.33 Section 10.33 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND... clients. A practitioner may not solicit professional employment from a prospective client with whom the...
A micropatterning approach for imaging Cx43 dynamic trafficking to cell-cell borders
Zhang, Shan-Shan; Hong, SoonGweon; Kléber, André G.; Lee, Luke P.; Shaw, Robin M.
2014-01-01
The precise expression and timely delivery of connexin 43 (Cx43) proteins to form gap junctions are essential for electrical coupling of cardiomyocytes. Growing evidence supports a cytoskeletal-based trafficking paradigm for Cx43 delivery directly to adherens junctions at the intercalated disc. A limitation of Cx43 localization assays in cultured cells, in which cell-cell contacts are essential, is the inability to control for cell geometry or reproducibly generate contact points. Here we present a micropatterned cell pairing system well suited for live microscopy to examine how the microtubule and actin cytoskeleton confer specificity to Cx43 trafficking to precisely defined cell-cell junctions. This system can also be adapted for other cell types and used to study dynamic intracellular movements of other proteins important for cell-cell communication‥ PMID:24444605
Fordyce, Christopher B; Al-Khalidi, Hussein R; Jollis, James G; Roettig, Mayme L; Gu, Joan; Bagai, Akshay; Berger, Peter B; Corbett, Claire C; Dauerman, Harold L; Fox, Kathleen; Garvey, J Lee; Henry, Timothy D; Rokos, Ivan C; Sherwood, Matthew W; Wilson, B Hadley; Granger, Christopher B
2017-01-01
The Mission: Lifeline STEMI Systems Accelerator program, implemented in 16 US metropolitan regions, resulted in more patients receiving timely reperfusion. We assessed whether implementing key care processes was associated with system performance improvement. Hospitals (n=167 with 23 498 ST-segment-elevation myocardial infarction patients) were surveyed before (March 2012) and after (July 2014) program intervention. Data were merged with patient-level clinical data over the same period. For reperfusion, hospitals were grouped by whether a specific process of care was implemented, preexisting, or never implemented. Uptake of 4 key care processes increased after intervention: prehospital catheterization laboratory activation (62%-91%; P<0.001), single call transfer protocol from an outside facility (45%-70%; P<0.001), and emergency department bypass for emergency medical services direct presenters (48%-59%; P=0.002) and transfers (56%-79%; P=0.001). There were significant differences in median first medical contact-to-device times among groups implementing prehospital activation (88 minutes implementers versus 89 minutes preexisting versus 98 minutes nonimplementers; P<0.001 for comparisons). Similarly, patients treated at hospitals implementing single call transfer protocols had shorter median first medical contact-to-device times (112 versus 128 versus 152 minutes; P<0.001). Emergency department bypass was also associated with shorter median first medical contact-to-device times for emergency medical services direct presenters (84 versus 88 versus 94 minutes; P<0.001) and transfers (123 versus 127 versus 167 minutes; P<0.001). The Accelerator program increased uptake of key care processes, which were associated with improved system performance. These findings support efforts to implement regional ST-segment-elevation myocardial infarction networks focused on prehospital catheterization laboratory activation, single call transfer protocols, and emergency department bypass. © 2017 American Heart Association, Inc.
Brackley, Victoria; Ball, Kevin; Tor, Elaine
2018-05-12
The effectiveness of the swimming turn is highly influential to overall performance in competitive swimming. The push-off or wall contact, within the turn phase, is directly involved in determining the speed the swimmer leaves the wall. Therefore, it is paramount to develop reliable methods to measure the wall-contact-time during the turn phase for training and research purposes. The aim of this study was to determine the concurrent validity and reliability of the Pool Pad App to measure wall-contact-time during the freestyle and backstroke tumble turn. The wall-contact-times of nine elite and sub-elite participants were recorded during their regular training sessions. Concurrent validity statistics included the standardised typical error estimate, linear analysis and effect sizes while the intraclass correlating coefficient (ICC) was used for the reliability statistics. The standardised typical error estimate resulted in a moderate Cohen's d effect size with an R 2 value of 0.80 and the ICC between the Pool Pad and 2D video footage was 0.89. Despite these measurement differences, the results from this concurrent validity and reliability analyses demonstrated that the Pool Pad is suitable for measuring wall-contact-time during the freestyle and backstroke tumble turn within a training environment.
Silver-free Metallization Technology for Producing High Efficiency, Industrial Silicon Solar Cells
DOE Office of Scientific and Technical Information (OSTI.GOV)
Michaelson, Lynne M.; Munoz, Krystal; Karas, Joseph
The goal of this project is to provide a commercially viable Ag-free metallization technology that will both reduce cost and increase efficiency of standard silicon solar cells. By removing silver from the front grid metallization and replacing it with lower cost nickel, copper, and tin metal, the front grid direct materials costs will decrease. This reduction in material costs should provide a path to meeting the Sunshot 2020 goal of 1 dollar / W DC. As of today, plated contacts are not widely implemented in large scale manufacturing. For organizations that wish to implement pilot scale manufacturing, only two equipmentmore » choices exist. These equipment manufacturers do not supply plating chemistry. The main goal of this project is to provide a chemistry and equipment solution to the industry that enables reliable manufacturing of plated contacts marked by passing reliability results and higher efficiencies than silver paste front grid contacts. To date, there have been several key findings that point to plated contacts performing equal to or better than the current state of the art silver paste contacts. Poor adhesion and reliability concerns are a few of the hurdles for plated contacts, specifically plated nickel directly on silicon. A key finding of the Phase 1 budget period is that the plated contacts have the same adhesion as the silver paste controls. This is a huge win for plated contacts. With very little optimization work, state of the art electrical results for plated contacts on laser ablated lines have been demonstrated with efficiencies up to 19.1% and fill factors ~80% on grid lines 40-50 um wide. The silver paste controls with similar line widths demonstrate similar electrical results. By optimizing the emitter and grid design for the plated contacts, it is expected that the electrical performance will exceed the silver paste controls. In addition, cells plated using Technic chemistry and equipment pass reliability testing; i.e. 1000 hours damp heat and 200 thermal cycles, with results similar to silver paste control cells. 100 cells have been processed through Technic’s novel demo plating tool built and installed during budget period 2. This plating tool performed consistently from cell to cell, providing gentle handling for the solar cells. An agreement has been signed with a cell manufacturer to process their cells through our plating chemistry and equipment. Their main focus for plated contacts is to reduce the direct materials cost by utilizing nickel, copper, and tin in place of silver paste. Based on current market conditions and cost model calculations, the overall savings offered by plated contacts is only 3.5% dollar/W versus silver paste contacts; however, the direct materials savings depend on the silver market. If silver prices increase, plated contacts may find a wider adoption in the solar industry in order to keep the direct materials costs down for front grid contacts.« less
Evaporation-induced flow in an inviscid liquid line at any contact angle
NASA Astrophysics Data System (ADS)
Petsi, A. J.; Burganos, V. N.
2006-04-01
The problem of potential flow inside an evaporating liquid line, shaped as an infinitely long cylindrical segment lying on a flat surface, is considered and an analytical solution is obtained for any contact angle in (0,π) . In this way, microflow details inside linear liquid bodies evaporating on hydrophilic, hydrophobic, and strongly hydrophobic substrates can now be obtained. The mathematical formulation employs the velocity potential and stream function formulations in bipolar coordinates and the solution is obtained using the technique of Fourier transform. Both pinned and depinned contact lines are considered. The solution is applicable to any evaporation mechanism but for illustration purposes numerical results are presented here for the particular case of kinetically controlled evaporation. For hydrophilic substrates, the flow inside the evaporating liquid line is directed towards the edges for pinned contact lines, thus, promoting a coffee stain effect. The opposite flow direction is observed for depinned contact lines. However, for strongly hydrophobic substrates, flow is directed outwards for both pinned and depinned contact lines, but owing to its low magnitude compared to that on hydrophilic substrates, a craterlike colloidal deposit should be expected rather than a ringlike deposit, in agreement with experimental observations.
Zhang, Jianguo; Müller-Plathe, Florian; Leroy, Frédéric
2015-07-14
The question of the effect of surface heterogeneities on the evaporation of liquid droplets from solid surfaces is addressed through nonequilibrium molecular dynamics simulations. The mechanism behind contact line pinning which is still unclear is discussed in detail on the nanoscale. Model systems with the Lennard-Jones interaction potential were employed to study the evaporation of nanometer-sized cylindrical droplets from a flat surface. The heterogeneity of the surface was modeled through alternating stripes of equal width but two chemical types. The first type leads to a contact angle of 67°, and the other leads to a contact angle of 115°. The stripe width was varied between 2 and 20 liquid-particle diameters. On the surface with the narrowest stripes, evaporation occurred at constant contact angle as if the surface was homogeneous, with a value of the contact angle as predicted by the regular Cassie-Baxter equation. When the width was increased, the contact angle oscillated during evaporation between two boundaries whose values depend on the stripe width. The evaporation behavior was thus found to be a direct signature of the typical size of the surface heterogeneity domains. The contact angle both at equilibrium and during evaporation could be predicted from a local Cassie-Baxter equation in which the surface composition within a distance of seven fluid-particle diameters around the contact line was considered, confirming the local nature of the interactions that drive the wetting behavior of droplets. More importantly, we propose a nanoscale explanation of pinning during evaporation. Pinning should be interpreted as a drastic slowdown of the contact line dynamics rather than a complete immobilization of it during a transition between two contact angle boundaries.
Cardoso-Neto, J.E.; Williams, D.W.
1995-01-01
A purge water management system is described for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.
Cardoso-Neto, Joao E.; Williams, Daniel W.
1996-01-01
A purge water management system for effectively eliminating the production of purge water when obtaining a groundwater sample from a monitoring well. In its preferred embodiment, the purge water management system comprises an expandable container, a transportation system, and a return system. The purge water management system is connected to a wellhead sampling configuration, typically permanently installed at the well site. A pump, positioned with the monitoring well, pumps groundwater through the transportation system into the expandable container, which expands in direct proportion with volume of groundwater introduced, usually three or four well volumes, yet prevents the groundwater from coming into contact with the oxygen in the air. After this quantity of groundwater has been removed from the well, a sample is taken from a sampling port, after which the groundwater in the expandable container can be returned to the monitoring well through the return system. The purge water management system prevents the purge water from coming in contact with the outside environment, especially oxygen, which might cause the constituents of the groundwater to oxidize. Therefore, by introducing the purge water back into the monitoring well, the necessity of dealing with the purge water as a hazardous waste under the Resource Conservation and Recovery Act is eliminated.
Determination of contact angle from the maximum height of enlarged drops on solid surfaces
NASA Astrophysics Data System (ADS)
Behroozi, F.
2012-04-01
Measurement of the liquid/solid contact angle provides useful information on the wetting properties of fluids. In 1870, the German physicist Georg Hermann Quincke (1834-1924) published the functional relation between the maximum height of an enlarged drop and its contact angle. Quincke's relation offered an alternative to the direct measurement of contact angle, which in practice suffers from several experimental uncertainties. In this paper, we review Quincke's original derivation and show that it is based on a hidden assumption. We then present a new derivation that exposes this assumption and clarifies the conditions under which Quincke's relation is valid. To explore Quincke's relation experimentally, we measure the maximum height of enlarged water drops on several substrates and calculate the contact angle in each case. Our results are in good agreement with contact angles measured directly from droplet images.
Contact problem for an elastic reinforcement bonded to an elastic plate
NASA Technical Reports Server (NTRS)
Erdogan, F.; Civelek, M. B.
1974-01-01
The contact problem for a thin elastic reinforcement bonded to an elastic plate is considered. The stiffening layer is treated as an elastic membrane and the base plate is assumed to be an elastic continuum. The bonding between the two materials is assumed to be either one of direct adhesion or through a thin adhesive layer which is treated as a shear spring. The solution for the simple case in which both the stiffener and the base plate are treated as membranes is also given. The contact stress is obtained for a series of numerical examples. In the direct adhesion case the contact stress becomes infinite at the stiffener ends with a typical square root singularity for the continuum model and behaving as a delta function for the membrane model. In the case of bonding through an adhesive layer the contact stress becomes finite and continuous along the entire contact area.
NASA Technical Reports Server (NTRS)
Litvin, Faydor L.; Feng, Pin-Hao; Lagutin, Sergei A.
2000-01-01
In this report, we propose a new geometry for low-noise, increased-strength helical gears of the Novikov-Wildhaber type. Contact stresses are reduced as a result of their convex-concave gear tooth surfaces. The gear tooth surfaces are crowned in the profile direction to localize bearing contact and in the longitudinal direction to obtain a parabolic function of transmission errors. Such a function results in the reduction of noise and vibrations. Methods for the generation of the proposed gear tooth surfaces by grinding and hobbing are considered, and a tooth contact analysis (TCA) computer program to simulate meshing and contact is applied. The report also investigates the influence of misalignment on transmission errors and shift of bearing contact. Numerical examples to illustrate the developed approaches are proposed. The proposed geometry was patented by Ford/UIC (Serial Number 09-340-824, pending) on June 28, 1999.
Membrane Contact Sites: Complex Zones for Membrane Association and Lipid Exchange
Quon, Evan; Beh, Christopher T.
2015-01-01
Lipid transport between membranes within cells involves vesicle and protein carriers, but as agents of nonvesicular lipid transfer, the role of membrane contact sites has received increasing attention. As zones for lipid metabolism and exchange, various membrane contact sites mediate direct associations between different organelles. In particular, membrane contact sites linking the plasma membrane (PM) and the endoplasmic reticulum (ER) represent important regulators of lipid and ion transfer. In yeast, cortical ER is stapled to the PM through membrane-tethering proteins, which establish a direct connection between the membranes. In this review, we consider passive and facilitated models for lipid transfer at PM–ER contact sites. Besides the tethering proteins, we examine the roles of an additional repertoire of lipid and protein regulators that prime and propagate PM–ER membrane association. We conclude that instead of being simple mediators of membrane association, regulatory components of membrane contact sites have complex and multilayered functions. PMID:26949334
21 CFR 882.1570 - Powered direct-contact temperature measurement device.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered direct-contact temperature measurement device. 882.1570 Section 882.1570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882...
21 CFR 882.1570 - Powered direct-contact temperature measurement device.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Powered direct-contact temperature measurement device. 882.1570 Section 882.1570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882...
Linden, M; Gothe, H; Ormel, J
2003-12-01
The comparison of different health care systems is one way to give empirical evidence to health care reform and policy. The differences between health care systems in which general practitioners serve as gate keepers in comparison to systems in which patients are free to contact every physician and specialist they like are a question of high interest. This study compares the Netherlands and Germany, two countries with very similar political, social, and health system structures, but different types of access to the health care system. While Germany offers unconstrained access to specialist ambulatory care, the Netherlands restricts health care utilization by giving primary care a 'gate keeper' function not allowing patients direct access to specialist care. Data from the WHO international collaborative study on psychological problems in general health care (Ustün and Sartorius 1995) were analysed with respect to pathways to care, treatment, and health status. In an initial cross-sectional assessment, in 3-month and 12-month follow-ups, contacts to physicians or hospital admission have also been monitored. There were only marginal differences between the Dutch and the German sample in the sociodemographic characteristics as well as in the diagnostic status with respect to mental disorders. In the Netherlands, 95.5%, and in Germany, 68.8% of the patients presented their 'reason for visit' for the first time to any physician at this index contact with a general practitioner. During the following 3 months, 24% of the Dutch patients, but 60.2% of the German patients, additionally contacted other physicians ( P < 0.001). At 12 months, this rate was 62.9% vs. 78.6% ( P < 0.001). During the 12-month follow-up period, there were 15.7 0/00 hospital admissions in Germany vs. 25.4 0/00 in the Netherlands ( P < 0.005) [corrected]. Family physicians in a gate keeper system reduce the number of contacts to other physicians and the intensity of treatment, while at the same time the rate of hospital admissions is increased.
Contribution of Visual Information about Ball Trajectory to Baseball Hitting Accuracy
Higuchi, Takatoshi; Nagami, Tomoyuki; Nakata, Hiroki; Watanabe, Masakazu; Isaka, Tadao; Kanosue, Kazuyuki
2016-01-01
The contribution of visual information about a pitched ball to the accuracy of baseball-bat contact may vary depending on the part of trajectory seen. The purpose of the present study was to examine the relationship between hitting accuracy and the segment of the trajectory of the flying ball that can be seen by the batter. Ten college baseball field players participated in the study. The systematic error and standardized variability of ball-bat contact on the bat coordinate system and pitcher-to-catcher direction when hitting a ball launched from a pitching machine were measured with or without visual occlusion and analyzed using analysis of variance. The visual occlusion timing included occlusion from 150 milliseconds (ms) after the ball release (R+150), occlusion from 150 ms before the expected arrival of the launched ball at the home plate (A-150), and a condition with no occlusion (NO). Twelve trials in each condition were performed using two ball speeds (31.9 m·s-1 and 40.3 m·s-1). Visual occlusion did not affect the mean location of ball-bat contact in the bat’s long axis, short axis, and pitcher-to-catcher directions. Although the magnitude of standardized variability was significantly smaller in the bat’s short axis direction than in the bat’s long axis and pitcher-to-catcher directions (p < 0.001), additional visible time from the R+150 condition to the A-150 and NO conditions resulted in a further decrease in standardized variability only in the bat’s short axis direction (p < 0.05). The results suggested that there is directional specificity in the magnitude of standardized variability with different visible time. The present study also confirmed the limitation to visual information is the later part of the ball trajectory for improving hitting accuracy, which is likely due to visuo-motor delay. PMID:26848742
Contribution of Visual Information about Ball Trajectory to Baseball Hitting Accuracy.
Higuchi, Takatoshi; Nagami, Tomoyuki; Nakata, Hiroki; Watanabe, Masakazu; Isaka, Tadao; Kanosue, Kazuyuki
2016-01-01
The contribution of visual information about a pitched ball to the accuracy of baseball-bat contact may vary depending on the part of trajectory seen. The purpose of the present study was to examine the relationship between hitting accuracy and the segment of the trajectory of the flying ball that can be seen by the batter. Ten college baseball field players participated in the study. The systematic error and standardized variability of ball-bat contact on the bat coordinate system and pitcher-to-catcher direction when hitting a ball launched from a pitching machine were measured with or without visual occlusion and analyzed using analysis of variance. The visual occlusion timing included occlusion from 150 milliseconds (ms) after the ball release (R+150), occlusion from 150 ms before the expected arrival of the launched ball at the home plate (A-150), and a condition with no occlusion (NO). Twelve trials in each condition were performed using two ball speeds (31.9 m·s-1 and 40.3 m·s-1). Visual occlusion did not affect the mean location of ball-bat contact in the bat's long axis, short axis, and pitcher-to-catcher directions. Although the magnitude of standardized variability was significantly smaller in the bat's short axis direction than in the bat's long axis and pitcher-to-catcher directions (p < 0.001), additional visible time from the R+150 condition to the A-150 and NO conditions resulted in a further decrease in standardized variability only in the bat's short axis direction (p < 0.05). The results suggested that there is directional specificity in the magnitude of standardized variability with different visible time. The present study also confirmed the limitation to visual information is the later part of the ball trajectory for improving hitting accuracy, which is likely due to visuo-motor delay.
Non-contact lateral force microscopy.
Weymouth, A J
2017-08-16
The goal of atomic force microscopy (AFM) is to measure the short-range forces that act between the tip and the surface. The signal recorded, however, includes long-range forces that are often an unwanted background. Lateral force microscopy (LFM) is a branch of AFM in which a component of force perpendicular to the surface normal is measured. If we consider the interaction between tip and sample in terms of forces, which have both direction and magnitude, then we can make a very simple yet profound observation: over a flat surface, long-range forces that do not yield topographic contrast have no lateral component. Short-range interactions, on the other hand, do. Although contact-mode is the most common LFM technique, true non-contact AFM techniques can be applied to perform LFM without the tip depressing upon the sample. Non-contact lateral force microscopy (nc-LFM) is therefore ideal to study short-range forces of interest. One of the first applications of nc-LFM was the study of non-contact friction. A similar setup is used in magnetic resonance force microscopy to detect spin flipping. More recently, nc-LFM has been used as a true microscopy technique to systems unsuitable for normal force microscopy.
The stability of the contact interface of cylindrical and spherical shock tubes
NASA Astrophysics Data System (ADS)
Crittenden, Paul E.; Balachandar, S.
2018-06-01
The stability of the contact interface for radial shock tubes is investigated as a model for explosive dispersal. The advection upstream splitting method with velocity and pressure diffusion (AUSM+-up) is used to solve for the radial base flow. To investigate the stability of the resulting contact interface, perturbed governing equations are derived assuming harmonic modes in the transverse directions. The perturbed harmonic flow is solved by assuming an initial disturbance and using a perturbed version of AUSM+-up derived in this paper. The intensity of the perturbation near the contact interface is computed and compared to theoretical results obtained by others. Despite the simplifying assumptions of the theoretical analysis, very good agreement is observed. Not only can the magnitude of the instability be predicted during the initial expansion, but also remarkably the agreement between the numerical and theoretical results can be maintained through the collision between the secondary shock and the contact interface. Since the theoretical results only depend upon the time evolution of the base flow, the stability of various modes could be quickly investigated without explicitly solving a system of partial differential equations for the perturbed flow.
NASA Technical Reports Server (NTRS)
Kanemitsu, Yoichi; Watanabe, Katsuhide; Yano, Kenichi; Mizuno, Takayuki
1994-01-01
This paper introduces a study on an Electromagnetically Levitated Vibration Isolation System (ELVIS) for isolation control of large-scale vibration. This system features no mechanical contact between the isolation table and the installation floor, using a total of four electromagnetic actuators which generate magnetic levitation force in the vertical and horizontal directions. The configuration of the magnet for the vertical direction is designed to prevent any generation of restoring vibratory force in the horizontal direction. The isolation system is set so that vibration control effects due to small earthquakes can be regulated to below 5(gal) versus horizontal vibration levels of the installation floor of up t 25(gal), and those in the horizontal relative displacement of up to 30 (mm) between the floor and levitated isolation table. In particular, studies on the relative displacement between the installation floor and the levitated isolation table have been made for vibration control in the horizontal direction. In case of small-scale earthquakes (Taft wave scaled: max. 25 gal), the present system has been confirmed to achieve a vibration isolation to a level below 5 gal. The vibration transmission ratio of below 1/10 has been achieved versus continuous micro-vibration (approx. one gal) in the horizontal direction on the installation floor.
Automatic measurement of contact angle in pore-space images
NASA Astrophysics Data System (ADS)
AlRatrout, Ahmed; Raeini, Ali Q.; Bijeljic, Branko; Blunt, Martin J.
2017-11-01
A new approach is presented to measure the in-situ contact angle (θ) between immiscible fluids, applied to segmented pore-scale X-ray images. We first identify and mesh the fluid/fluid and fluid/solid interfaces. A Gaussian smoothing is applied to this mesh to eliminate artifacts associated with the voxelized nature of the image, while preserving large-scale features of the rock surface. Then, for the fluid/fluid interface we apply an additional smoothing and adjustment of the mesh to impose a constant curvature. We then track the three-phase contact line, and the two vectors that have a direction perpendicular to both surfaces: the contact angle is found from the dot product of these vectors where they meet at the contact line. This calculation can be applied at every point on the mesh at the contact line. We automatically generate contact angle values representing each invaded pore-element in the image with high accuracy. To validate the approach, we first study synthetic three-dimensional images of a spherical droplet of oil residing on a tilted flat solid surface surrounded by brine and show that our results are accurate to within 3° if the sphere diameter is 2 or more voxels. We then apply this method to oil/brine systems imaged at ambient temperature and reservoir pressure (10MPa) using X-ray microtomography (Singh et al., 2016). We analyse an image volume of diameter approximately 4.6 mm and 10.7 mm long, obtaining hundreds of thousands of values from a dataset with around 700 million voxels. We show that in a system of altered wettability, contact angles both less than and greater than 90° can be observed. This work provides a rapid method to provide an accurate characterization of pore-scale wettability, which is important for the design and assessment of hydrocarbon recovery and carbon dioxide storage.
Apparatus and method for feeding coal into a coal gasifier
Bissett, Larry A.; Friggens, Gary R.; McGee, James P.
1979-01-01
This invention is directed to a system for feeding coal into a gasifier operating at high pressures. A coal-water slurry is pumped to the desired pressure and then the coal is "dried" prior to feeding the coal into the gasifier by contacting the slurry with superheated steam in an entrained bed dryer for vaporizing the water in the slurry.
21 CFR 886.5916 - Rigid gas permeable contact lens.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn directly...
21 CFR 886.5916 - Rigid gas permeable contact lens.
Code of Federal Regulations, 2011 CFR
2011-04-01
... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn directly...
Federal Register 2010, 2011, 2012, 2013, 2014
2012-03-02
..., Contact Information and Work History for Nonimmigrant Visa Applicant ACTION: Notice of request for public... with the Paperwork Reduction Act of 1995. Title of Information Collection: Contact Information and Work... FURTHER INFORMATION CONTACT: Direct requests for additional information regarding the collection listed in...
Endoplasmic Reticulum-Plasma Membrane Contact Sites.
Saheki, Yasunori; De Camilli, Pietro
2017-06-20
The endoplasmic reticulum (ER) has a broad localization throughout the cell and forms direct physical contacts with all other classes of membranous organelles, including the plasma membrane (PM). A number of protein tethers that mediate these contacts have been identified, and study of these protein tethers has revealed a multiplicity of roles in cell physiology, including regulation of intracellular Ca 2+ dynamics and signaling as well as control of lipid traffic and homeostasis. In this review, we discuss the cross talk between the ER and the PM mediated by direct contacts. We review factors that tether the two membranes, their properties, and their dynamics in response to the functional state of the cell. We focus in particular on the role of ER-PM contacts in nonvesicular lipid transport between the two bilayers mediated by lipid transfer proteins.
Cross-border healthcare: Directive 2011/24 and the Greek law.
Vidalis, Takis; Kyriakaki, Irini
2014-03-01
The Greek legal framework on healthcare is characterized by the complexity of an immense number of laws and regulatory acts, particularly regarding the national health system. In the face front of that problem, the Directive stands as an effort (and an opportunity) to achieve a regulatory rationalization. The Law 3918/2011 established the National Organisation for Healthcare (EOPYY). EOPYY is the unique national contact point in the country for the purposes of the Directive, having a responsibility to ensure that the services provided by its affiliated healthcare providers meet certain quality and safety standards. Furthermore, the Greek legal system encompasses an integrated body of legislation on informed consent, privacy, and data protection, as well as an explicit reference to the 'quality, safety and efficiency' of medical services, and provisions related to reimbursement issues that need further regulatory specification.
Marouane, H; Shirazi-Adl, A; Adouni, M
2016-01-25
Evaluation of contact forces-centers of the tibiofemoral joint in gait has crucial biomechanical and pathological consequences. It involves however difficulties and limitations in in vitro cadaver and in vivo imaging studies. The goal is to estimate total contact forces (CF) and location of contact centers (CC) on the medial and lateral plateaus using results computed by a validated finite element model simulating the stance phase of gait for normal as well as osteoarthritis, varus-valgus and posterior tibial slope altered subjects. Using foregoing contact results, six methods commonly used in the literature are also applied to estimate and compare locations of CC at 6 periods of stance phase (0%, 5%, 25%, 50%, 75% and 100%). TF joint contact forces are greater on the lateral plateau very early in stance and on the medial plateau thereafter during 25-100% stance periods. Large excursions in the location of CC (>17mm), especially on the medial plateau in the mediolateral direction, are computed. Various reported models estimate quite different CCs with much greater variations (~15mm) in the mediolateral direction on both plateaus. Compared to our accurately computed CCs taken as the gold standard, the centroid of contact area algorithm yielded least differences (except in the mediolateral direction on the medial plateau at ~5mm) whereas the contact point and weighted center of proximity algorithms resulted overall in greatest differences. Large movements in the location of CC should be considered when attempting to estimate TF compartmental contact forces in gait. Copyright © 2015 Elsevier Ltd. All rights reserved.
Dahlöf, Linda; Simonsson, Anna; Thorn, Jörgen; Larsson, Maria Eh
2014-10-01
In a primary health-care centre (PHCC) situated in a segregated area with low socio-economic status, 'primary care triage' has increased efficiency and accessibility. In the primary-care triage, the nurse sorts the patient to the appropriate PHCC profession according to described symptoms. Aim The aim of this study was to examine the patients' experience of being triaged directly to a psychologist for assessment. Interviews were conducted with 20 patients and then analysed using qualitative content analysis. The results show that patients contacting the PHCC for mental health issues often are active agents with their own intent to see a psychologist, not a doctor, as a first-hand choice when contacting the PHCC. Seeking help for mental health issues is described as a sensitive issue that demands building up strength before contacting. The quick access to the preferred health-care professional is appreciated. The nurse was perceived as a caring facilitator rather than a decision maker. It is the patient's wish rather than the symptoms that directs the sorting. The patients' expectations when meeting the psychologist were wide and diverse. The structured assessment sometimes collided and sometimes united with these expectations, yielding different outcome satisfaction. The results could be seen in line with the present goal to increase patients' choice in the health-care system. The improved accessibility to the psychologist seems to meet community expectations. The results also indicate a need for providing more prior information about the assessment and potential outcomes.
The Spacecraft Emergency Response System (SERS) for Autonomous Mission Operations
NASA Technical Reports Server (NTRS)
Breed, Julia; Chu, Kai-Dee; Baker, Paul; Starr, Cynthia; Fox, Jeffrey; Baitinger, Mick
1998-01-01
Today, most mission operations are geared toward lowering cost through unmanned operations. 7-day/24-hour operations are reduced to either 5-day/8-hour operations or become totally autonomous, especially for deep-space missions. Proper and effective notification during a spacecraft emergency could mean success or failure for an entire mission. The Spacecraft Emergency Response System (SERS) is a tool designed for autonomous mission operations. The SERS automatically contacts on-call personnel as needed when crises occur, either on-board the spacecraft or within the automated ground systems. Plus, the SERS provides a group-ware solution to facilitate the work of the person(s) contacted. The SERS is independent of the spacecraft's automated ground system. It receives and catalogues reports for various ground system components in near real-time. Then, based on easily configurable parameters, the SERS determines whom, if anyone, should be alerted. Alerts may be issued via Sky-Tel 2-way pager, Telehony, or e-mail. The alerted personnel can then review and respond to the spacecraft anomalies through the Netscape Internet Web Browser, or directly review and respond from the Sky-Tel 2-way pager.
NASA Astrophysics Data System (ADS)
Ferry, John M.; Wing, Boswell A.; Penniston-Dorland, Sarah C.; Rumble, Douglas
2002-03-01
Periclase formed in siliceous dolomitic marbles during contact metamorphism in the Monzoni and Predazzo aureoles, the Dolomites, northern Italy, by infiltration of the carbonate rocks by chemically reactive, H2O-rich fluids at 500 bar and 565-710 °C. The spatial distribution of periclase and oxygen isotope compositions is consistent with reactive fluid flow that was primarily vertical and upward in both aureoles with time-integrated flux ~5,000 and ~300 mol fluid/cm2 rock in the Monzoni and Predazzo aureoles, respectively. The new results for Monzoni and Predazzo are considered along with published studies of 13 other aureoles to draw general conclusions about the direction, amount, and controls on the geometry of reactive fluid flow during contact metamorphism of siliceous carbonate rocks. Flow in 12 aureoles was primarily vertically upward with and without a horizontal component directed away from the pluton. Fluid flow in two of the other three was primarily horizontal, directed from the pluton into the aureole. The direction of flow in the remaining aureole is uncertain. Earlier suggestions that fluid flow is often horizontal, directed toward the pluton, are likely explained by an erroneous assumption that widespread coexisting mineral reactants and products represent arrested prograde decarbonation reactions. With the exception of three samples from one aureole, time-integrated fluid flux was in the range 102-104 mol/cm2. Both the amount and direction of fluid flow are consistent with hydrodynamic models of contact metamorphism. The orientation of bedding and lithologic contacts appears to be the principal control over whether fluid flow was either primarily vertical or horizontal. Other pre-metamorphic structures, including dikes, faults, fold hinges, and fracture zones, served to channel fluid flow as well.
NASA Astrophysics Data System (ADS)
Ferry, John; Wing, Boswell; Penniston-Dorland, Sarah; Rumble, Douglas
2001-11-01
Periclase formed in siliceous dolomitic marbles during contact metamorphism in the Monzoni and Predazzo aureoles, the Dolomites, northern Italy, by infiltration of the carbonate rocks by chemically reactive, H2O-rich fluids at 500 bar and 565-710 °C. The spatial distribution of periclase and oxygen isotope compositions is consistent with reactive fluid flow that was primarily vertical and upward in both aureoles with time-integrated flux 5,000 and 300 mol fluid/cm2 rock in the Monzoni and Predazzo aureoles, respectively. The new results for Monzoni and Predazzo are considered along with published studies of 13 other aureoles to draw general conclusions about the direction, amount, and controls on the geometry of reactive fluid flow during contact metamorphism of siliceous carbonate rocks. Flow in 12 aureoles was primarily vertically upward with and without a horizontal component directed away from the pluton. Fluid flow in two of the other three was primarily horizontal, directed from the pluton into the aureole. The direction of flow in the remaining aureole is uncertain. Earlier suggestions that fluid flow is often horizontal, directed toward the pluton, are likely explained by an erroneous assumption that widespread coexisting mineral reactants and products represent arrested prograde decarbonation reactions. With the exception of three samples from one aureole, time-integrated fluid flux was in the range 102-104 mol/cm2. Both the amount and direction of fluid flow are consistent with hydrodynamic models of contact metamorphism. The orientation of bedding and lithologic contacts appears to be the principal control over whether fluid flow was either primarily vertical or horizontal. Other pre-metamorphic structures, including dikes, faults, fold hinges, and fracture zones, served to channel fluid flow as well.
Fabrication of 3D surface structures using grayscale lithography
NASA Astrophysics Data System (ADS)
Stilson, Christopher; Pal, Rajan; Coutu, Ronald A.
2014-03-01
The ability to design and develop 3D microstructures is important for microelectromechanical systems (MEMS) fabrication. Previous techniques used to create 3D devices included tedious steps in direct writing and aligning patterns onto a substrate followed by multiple photolithography steps using expensive, customized equipment. Additionally, these techniques restricted batch processing and placed limits on achievable shapes. Gray-scale lithography enables the fabrication of a variety of shapes using a single photolithography step followed by reactive ion etching (RIE). Micromachining 3D silicon structures for MEMS can be accomplished using gray-scale lithography along with dry anisotropic etching. In this study, we investigated: using MATLAB for mask designs; feasibility of using 1 μm Heidelberg mask maker to direct write patterns onto photoresist; using RIE processing to etch patterns into a silicon substrate; and the ability to tailor etch selectivity for precise fabrication. To determine etch rates and to obtain desired etch selectivity, parameters such as gas mixture, gas flow, and electrode power were studied. This process successfully demonstrates the ability to use gray-scale lithography and RIE for use in the study of micro-contacts. These results were used to produce a known engineered non-planer surface for testing micro-contacts. Surface structures are between 5 μm and 20 μm wide with varying depths and slopes based on mask design and etch rate selectivity. The engineered surfaces will provide more insight into contact geometries and failure modes of fixed-fixed micro-contacts.
Technical and economic evaluation of a Brayton-Rankine combined cycle solar-thermal power plant
NASA Astrophysics Data System (ADS)
Wright, J. D.; Copeland, R. J.
1981-05-01
An assessment of gas-liquid direct-contact heat exchange and of a new storage-coupled system was conducted. Both technical and economic issues are evaluated. Specifically, the storage-coupled combined cycle is compared with a molten salt system. The open Brayton cycle system is used as a topping cycle, and the reject heat powers the molten salt/Rankine system. In this study the molten salt system is left unmodified, the Brayton cycle is integrated on top of a Marietta description of an existing molten salt plant. This compares a nonoptimized combined cycle with an optimized molten salt system.
Contact Hamiltonian systems and complete integrability
NASA Astrophysics Data System (ADS)
Visinescu, Mihai
2017-12-01
We summarize recent results on the integrability of Hamiltonian systems on contact manifolds. We explain how to extend the classical formulation of action-angle variables to contact integrable systems. Using the Jacobi brackets defined on contact manifolds, we discuss the commutativity of first integrals for contact Hamiltonian systems and present the construction of generalized contact action-angle variables. We illustrate the integrability in the contact geometry on the five-dimensional Sasaki-Einstein spaces T1,1 and Yp,q.
Refrigeration arrangement and methods for reducing charge migration
DOE Office of Scientific and Technical Information (OSTI.GOV)
Litch, Andrew D.; Wu, Guolian
A refrigerator appliance including a refrigerant circuit between a condenser, an evaporator, and a compressor that includes two conduits and pressure reducing devices arranged in parallel between the evaporator and the condenser. The appliance also includes a valve system to direct refrigerant through one, both or none of the conduits and pressure reducing devices, and a heat exchanging member in thermal contact with either one pressure reducing device, or one conduit between the pressure reducing device and the valve system.
Ren, Hao; Liu, Ning-Yu; Andreasen, Arne; Thomsen, Jesper S; Cao, Liu; Christensen, Erik I; Zhai, Xiao-Yue
2013-01-01
Recent physiological studies in the kidney proposed the existence of a secondary feedback mechanism termed 'crosstalk' localized after the macula densa. This newly discovered crosstalk contact between the nephron tubule and its own afferent arteriole may potentially revolutionize our understanding of renal vascular resistance and electrolyte regulation. However, the nature of such a crosstalk mechanism is still debated due to a lack of direct and comprehensive morphological evidence. Its exact location along the nephron, its prevalence among the different types of nephrons, and the type of cells involved are yet unknown. To address these issues, computer assisted 3-dimensional nephron tracing was applied in combination with direct immunohistochemistry on plastic sections and electron microscopy. 'Random' contacts in the cortex were identified by the tracing and excluded. We investigated a total of 168 nephrons from all cortical regions. The results demonstrated that the crosstalk contact existed, and that it was only present in certain nephrons (90% of the short-looped and 75% of the long-looped nephrons). The crosstalk contacts always occurred at a specific position--the last 10% of the distal convoluted tubule. Importantly, we demonstrated, for the first time, that the cells found in the tubule wall at the contact site were always type nonA-nonB intercalated cells. In conclusion, the present work confirmed the existence of a post macula densa physical crosstalk contact.
Directional Collective Cell Migration Emerges as a Property of Cell Interactions
Woods, Mae L.; Carmona-Fontaine, Carlos; Barnes, Chris P.; Couzin, Iain D.; Mayor, Roberto; Page, Karen M.
2014-01-01
Collective cell migration is a fundamental process, occurring during embryogenesis and cancer metastasis. Neural crest cells exhibit such coordinated migration, where aberrant motion can lead to fatality or dysfunction of the embryo. Migration involves at least two complementary mechanisms: contact inhibition of locomotion (a repulsive interaction corresponding to a directional change of migration upon contact with a reciprocating cell), and co-attraction (a mutual chemoattraction mechanism). Here, we develop and employ a parameterized discrete element model of neural crest cells, to investigate how these mechanisms contribute to long-range directional migration during development. Motion is characterized using a coherence parameter and the time taken to reach, collectively, a target location. The simulated cell group is shown to switch from a diffusive to a persistent state as the response-rate to co-attraction is increased. Furthermore, the model predicts that when co-attraction is inhibited, neural crest cells can migrate into restrictive regions. Indeed, inhibition of co-attraction in vivo and in vitro leads to cell invasion into restrictive areas, confirming the prediction of the model. This suggests that the interplay between the complementary mechanisms may contribute to guidance of the neural crest. We conclude that directional migration is a system property and does not require action of external chemoattractants. PMID:25181349
... the skin to become scaly and inflamed), and contact dermatitis (caused by direct skin contact with an irritating substance, such as a metal, ... How Do I Get Rid of Eczema Scars? Eczema Impetigo View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & ...
Industrial applications of the air direct-contact, gravel, ground heat exchanger
NASA Astrophysics Data System (ADS)
Cepiński, Wojciech; Besler, Maciej
2017-11-01
The paper describes the analysis of possibility of using the air direct-contact, gravel, ground heat exchanger (Polish acronym BGWCiM), patented at the Wroclaw University of Science and Technology to prepare air for conditioning rooms in the industry. Indicated the industry sectors where the application may be the most beneficial.
Validation of radiocarpal joint contact models based on images from a clinical MRI scanner.
Johnson, Joshua E; McIff, Terence E; Lee, Phil; Toby, E Bruce; Fischer, Kenneth J
2014-01-01
This study was undertaken to assess magnetic resonance imaging (MRI)-based radiocarpal surface contact models of functional loading in a clinical MRI scanner for future in vivo studies, by comparison with experimental measures from three cadaver forearm specimens. Experimental data were acquired using a Tekscan sensor during simulated light grasp. Magnetic resonance (MR) images were used to obtain model geometry and kinematics (image registration). Peak contact pressures (PPs) and average contact pressures (APs), contact forces and contact areas were determined in the radiolunate and radioscaphoid joints. Contact area was also measured directly from MR images acquired with load and compared with model data. Based on the validation criteria (within 25% of experimental data), out of the six articulations (three specimens with two articulations each), two met the criterion for AP (0%, 14%); one for peak pressure (20%); one for contact force (5%); four for contact area with respect to experiment (8%, 13%, 19% and 23%), and three contact areas met the criterion with respect to direct measurements (14%, 21% and 21%). Absolute differences between model and experimental PPs were reasonably low (within 2.5 MPa). Overall, the results indicate that MRI-based models generated from 3T clinical MR scanner appear sufficient to obtain clinically relevant data.
Koishi, Takahiro; Yasuoka, Kenji; Fujikawa, Shigenori; Zeng, Xiao Cheng
2011-09-27
We perform large-scale molecular dynamics simulations to measure the contact-angle hysteresis for a nanodroplet of water placed on a nanopillared surface. The water droplet can be in either the Cassie state (droplet being on top of the nanopillared surface) or the Wenzel state (droplet being in contact with the bottom of nanopillar grooves). To measure the contact-angle hysteresis in a quantitative fashion, the molecular dynamics simulation is designed such that the number of water molecules in the droplets can be systematically varied, but the number of base nanopillars that are in direct contact with the droplets is fixed. We find that the contact-angle hysteresis for the droplet in the Cassie state is weaker than that in the Wenzel state. This conclusion is consistent with the experimental observation. We also test a different definition of the contact-angle hysteresis, which can be extended to estimate hysteresis between the Cassie and Wenzel state. The idea is motivated from the appearance of the hysteresis loop typically seen in computer simulation of the first-order phase transition, which stems from the metastability of a system in different thermodynamic states. Since the initial shape of the droplet can be controlled arbitrarily in the computer simulation, the number of base nanopillars that are in contact with the droplet can be controlled as well. We show that the measured contact-angle hysteresis according to the second definition is indeed very sensitive to the initial shape of the droplet. Nevertheless, the contact-angle hystereses measured based on the conventional and new definition seem converging in the large droplet limit. © 2011 American Chemical Society
Bombara, Courtenay B; Dürr, Salome; Machovsky-Capuska, Gabriel E; Jones, Peter W; Ward, Michael P
2017-01-01
Information on contacts between individuals within a population is crucial to inform disease control strategies, via parameterisation of disease spread models. In this study we investigated the use of dog-borne video cameras-in conjunction with global positioning systems (GPS) loggers-to both characterise dog-to-dog contacts and to estimate contact rates. We customized miniaturised video cameras, enclosed within 3D-printed plastic cases, and attached these to nylon dog collars. Using two 3400 mAh NCR lithium Li-ion batteries, cameras could record a maximum of 22 hr of continuous video footage. Together with a GPS logger, collars were attached to six free roaming domestic dogs (FRDDs) in two remote Indigenous communities in northern Australia. We recorded a total of 97 hr of video footage, ranging from 4.5 to 22 hr (mean 19.1) per dog, and observed a wide range of social behaviours. The majority (69%) of all observed interactions between community dogs involved direct physical contact. Direct contact behaviours included sniffing, licking, mouthing and play fighting. No contacts appeared to be aggressive, however multiple teeth baring incidents were observed during play fights. We identified a total of 153 contacts-equating to 8 to 147 contacts per dog per 24 hr-from the videos of the five dogs with camera data that could be analysed. These contacts were attributed to 42 unique dogs (range 1 to 19 per video) which could be identified (based on colour patterns and markings). Most dog activity was observed in urban (houses and roads) environments, but contacts were more common in bushland and beach environments. A variety of foraging behaviours were observed, included scavenging through rubbish and rolling on dead animal carcasses. Identified food consumed included chicken, raw bones, animal carcasses, rubbish, grass and cheese. For characterising contacts between FRDD, several benefits of analysing videos compared to GPS fixes alone were identified in this study, including visualisation of the nature of the contact between two dogs; and inclusion of a greater number of dogs in the study (which do not need to be wearing video or GPS collars). Some limitations identified included visualisation of contacts only during daylight hours; the camera lens being obscured on occasion by the dog's mandible or the dog resting on the camera; an insufficiently wide viewing angle (36°); battery life and robustness of the deployments; high costs of the deployment; and analysis of large volumes of often unsteady video footage. This study demonstrates that dog-borne video cameras, are a feasible technology for estimating and characterising contacts between FRDDs. Modifying camera specifications and developing new analytical methods will improve applicability of this technology for monitoring FRDD populations, providing insights into dog-to-dog contacts and therefore how disease might spread within these populations.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-10-24
... Regulations To Prohibit Public Contact With Big Cats, Bears, and Nonhuman Primates AGENCY: Animal and Plant... into direct or physical contact with big cats, bears, or nonhuman primates of any age, to define the... coming. FOR FURTHER INFORMATION CONTACT: Dr. Barbara Kohn, DVM, Senior Staff Officer, USDA, APHIS, Animal...
Fischer, William H.; Cookson, Alan H.; Yoon, Kue H.
1984-04-10
A particle trap to outer elongated conductor or sheath contact for gas-insulated transmission lines. The particle trap to outer sheath contact of the invention is applicable to gas-insulated transmission lines having either corrugated or non-corrugated outer sheaths. The contact of the invention includes an electrical contact disposed on a lever arm which in turn is rotatably disposed on the particle trap and biased in a direction to maintain contact between the electrical contact and the outer sheath.
Design and construction of a point-contact spectroscopy rig with lateral scanning capability.
Tortello, M; Park, W K; Ascencio, C O; Saraf, P; Greene, L H
2016-06-01
The design and realization of a cryogenic rig for point-contact spectroscopy measurements in the needle-anvil configuration is presented. Thanks to the use of two piezoelectric nano-positioners, the tip can move along the vertical (z) and horizontal (x) direction and thus the rig is suitable to probe different regions of a sample in situ. Moreover, it can also form double point-contacts on different facets of a single crystal for achieving, e.g., an interferometer configuration for phase-sensitive measurements. For the later purpose, the sample holder can also host a Helmholtz coil for applying a small transverse magnetic field to the junction. A semi-rigid coaxial cable can be easily added for studying the behavior of Josephson junctions under microwave irradiation. The rig can be detached from the probe and thus used with different cryostats. The performance of this new probe has been tested in a Quantum Design PPMS system by conducting point-contact Andreev reflection measurements on Nb thin films over large areas as a function of temperature and magnetic field.
Design and construction of a point-contact spectroscopy rig with lateral scanning capability
NASA Astrophysics Data System (ADS)
Tortello, M.; Park, W. K.; Ascencio, C. O.; Saraf, P.; Greene, L. H.
2016-06-01
The design and realization of a cryogenic rig for point-contact spectroscopy measurements in the needle-anvil configuration is presented. Thanks to the use of two piezoelectric nano-positioners, the tip can move along the vertical (z) and horizontal (x) direction and thus the rig is suitable to probe different regions of a sample in situ. Moreover, it can also form double point-contacts on different facets of a single crystal for achieving, e.g., an interferometer configuration for phase-sensitive measurements. For the later purpose, the sample holder can also host a Helmholtz coil for applying a small transverse magnetic field to the junction. A semi-rigid coaxial cable can be easily added for studying the behavior of Josephson junctions under microwave irradiation. The rig can be detached from the probe and thus used with different cryostats. The performance of this new probe has been tested in a Quantum Design PPMS system by conducting point-contact Andreev reflection measurements on Nb thin films over large areas as a function of temperature and magnetic field.
Design and construction of a point-contact spectroscopy rig with lateral scanning capability
DOE Office of Scientific and Technical Information (OSTI.GOV)
Tortello, M.; Park, W. K., E-mail: wkpark@illinois.edu; Ascencio, C. O.
2016-06-15
The design and realization of a cryogenic rig for point-contact spectroscopy measurements in the needle-anvil configuration is presented. Thanks to the use of two piezoelectric nano-positioners, the tip can move along the vertical (z) and horizontal (x) direction and thus the rig is suitable to probe different regions of a sample in situ. Moreover, it can also form double point-contacts on different facets of a single crystal for achieving, e.g., an interferometer configuration for phase-sensitive measurements. For the later purpose, the sample holder can also host a Helmholtz coil for applying a small transverse magnetic field to the junction. Amore » semi-rigid coaxial cable can be easily added for studying the behavior of Josephson junctions under microwave irradiation. The rig can be detached from the probe and thus used with different cryostats. The performance of this new probe has been tested in a Quantum Design PPMS system by conducting point-contact Andreev reflection measurements on Nb thin films over large areas as a function of temperature and magnetic field.« less
Phase field kinetics of lithium electrodeposits
NASA Astrophysics Data System (ADS)
Ely, David R.; Jana, Aniruddha; García, R. Edwin
2014-12-01
A phase field description is formulated to describe the growth kinetics of an heterogeneously nucleated distribution of lithium electrodeposits. The underlying variational principle includes the bulk electrochemical contributions to the free energy of transformation of the system, the electrolyte-dendrite interfacial energy, and the substrate work of adhesion energetics. Results demonstrate that the rate of electrodeposition at the tip of an isolated dendrite is higher than the rate corresponding to the average overpotential, while the back contact is electrochemically shielded, thus favoring elongated, needle-like shapes. For large populations of electrochemically interacting deposits, two spatially distinct regions of behavior develop: one directly facing the counter-electrode where the local surficial electrodeposition dominates the local kinetics; and a second region, in the vicinity of the substrate-deposit interface, where the electrochemical shielding induced by the tip enables lateral electrochemical lithium exchange dendrite coalescence for small contact angle deposits, and dendrite dewetting and electrodissolution for large contact angle deposits. The underlying physical mechanisms through which some lithium nuclei detach from the depositing substrate, self-induce electrodissolution, while other continue to grow and coalesce are described for different contact angles.
Non-contact evaluation of milk-based products using air-coupled ultrasound
NASA Astrophysics Data System (ADS)
Meyer, S.; Hindle, S. A.; Sandoz, J.-P.; Gan, T. H.; Hutchins, D. A.
2006-07-01
An air-coupled ultrasonic technique has been developed and used to detect physicochemical changes of liquid beverages within a glass container. This made use of two wide-bandwidth capacitive transducers, combined with pulse-compression techniques. The use of a glass container to house samples enabled visual inspection, helping to verify the results of some of the ultrasonic measurements. The non-contact pulse-compression system was used to evaluate agglomeration processes in milk-based products. It is shown that the amplitude of the signal varied with time after the samples had been treated with lactic acid, thus promoting sample destabilization. Non-contact imaging was also performed to follow destabilization of samples by scanning in various directions across the container. The obtained ultrasonic images were also compared to those from a digital camera. Coagulation with glucono-delta-lactone of skim milk poured into this container could be monitored within a precision of a pH of 0.15. This rapid, non-contact and non-destructive technique has shown itself to be a feasible method for investigating the quality of milk-based beverages, and possibly other food products.
Spatiotemporal Patterns of Contact Across the Rat Vibrissal Array During Exploratory Behavior
Hobbs, Jennifer A.; Towal, R. Blythe; Hartmann, Mitra J. Z.
2016-01-01
The rat vibrissal system is an important model for the study of somatosensation, but the small size and rapid speed of the vibrissae have precluded measuring precise vibrissal-object contact sequences during behavior. We used a laser light sheet to quantify, with 1 ms resolution, the spatiotemporal structure of whisker-surface contact as five naïve rats freely explored a flat, vertical glass wall. Consistent with previous work, we show that the whisk cycle cannot be uniquely defined because different whiskers often move asynchronously, but that quasi-periodic (~8 Hz) variations in head velocity represent a distinct temporal feature on which to lock analysis. Around times of minimum head velocity, whiskers protract to make contact with the surface, and then sustain contact with the surface for extended durations (~25–60 ms) before detaching. This behavior results in discrete temporal windows in which large numbers of whiskers are in contact with the surface. These “sustained collective contact intervals” (SCCIs) were observed on 100% of whisks for all five rats. The overall spatiotemporal structure of the SCCIs can be qualitatively predicted based on information about head pose and the average whisk cycle. In contrast, precise sequences of whisker-surface contact depend on detailed head and whisker kinematics. Sequences of vibrissal contact were highly variable, equally likely to propagate in all directions across the array. Somewhat more structure was found when sequences of contacts were examined on a row-wise basis. In striking contrast to the high variability associated with contact sequences, a consistent feature of each SCCI was that the contact locations of the whiskers on the glass converged and moved more slowly on the sheet. Together, these findings lead us to propose that the rat uses a strategy of “windowed sampling” to extract an object's spatial features: specifically, the rat spatially integrates quasi-static mechanical signals across whiskers during the period of sustained contact, resembling an “enclosing” haptic procedure. PMID:26778990
A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition
Fong, Ee-May; Chung, Wan-Young
2015-01-01
A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject’s skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3–15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio. PMID:26251913
Sibling cooperation in earwig families provides insights into the early evolution of social life.
Falk, Joachim; Wong, Janine W Y; Kölliker, Mathias; Meunier, Joël
2014-04-01
The evolutionary transition from solitary to social life is driven by direct and indirect fitness benefits of social interactions. Understanding the conditions promoting the early evolution of social life therefore requires identification of these benefits in nonderived social systems, such as animal families where offspring are mobile and able to disperse and will survive independently. Family life is well known to provide benefits to offspring through parental care, but research on sibling interactions generally focused on fitness costs to offspring due to competitive behaviors. Here we show experimentally that sibling interactions also reflect cooperative behaviors in the form of food sharing in nonderived families of the European earwig, Forficula auricularia. Food ingested by individual offspring was transferred to their siblings through mouth-to-anus contacts and active allo-coprophagy. These transfers occurred in both the presence and the absence of the tending mothers, even though the direct contact with the mothers limited sibling food sharing. Neither food deprivation or relatedness influenced the total amount of transferred food, but relatedness affected frass release and the behavioral mechanisms mediating food sharing. Related offspring obtained food predominately through allo-coprophagy, whereas unrelated offspring obtained food through mouth-to-anus contacts. Overall, this study emphasizes that sibling cooperation may be a key process promoting the early evolution of social life.
A Hygroscopic Sensor Electrode for Fast Stabilized Non-Contact ECG Signal Acquisition.
Fong, Ee-May; Chung, Wan-Young
2015-08-05
A capacitive electrocardiography (cECG) technique using a non-invasive ECG measuring technology that does not require direct contact between the sensor and the skin has attracted much interest. The system encounters several challenges when the sensor electrode and subject's skin are weakly coupled. Because there is no direct physical contact between the subject and any grounding point, there is no discharge path for the built-up electrostatic charge. Subsequently, the electrostatic charge build-up can temporarily contaminate the ECG signal from being clearly visible; a stabilization period (3-15 min) is required for the measurement of a clean, stable ECG signal at low humidity levels (below 55% relative humidity). Therefore, to obtain a clear ECG signal without noise and to reduce the ECG signal stabilization time to within 2 min in a dry ambient environment, we have developed a fabric electrode with embedded polymer (FEEP). The designed hygroscopic FEEP has an embedded superabsorbent polymer layer. The principle of FEEP as a conductive electrode is to provide humidity to the capacitive coupling to ensure strong coupling and to allow for the measurement of a stable, clear biomedical signal. The evaluation results show that hygroscopic FEEP is capable of rapidly measuring high-accuracy ECG signals with a higher SNR ratio.
Contact problem for an elastic reinforcement bonded to an elastic plate
NASA Technical Reports Server (NTRS)
Erdogan, F.; Civelek, M. B.
1973-01-01
The stiffening layer is treated as an elastic membrane and the base plate is assumed to be an elastic continuum. The bonding between the two materials is assumed to be either one of direct adhesion ro through a thin adhesive layer which is treated as a shear spring. The solution for the simple case in which both the stiffener and the base plate are treated as membranes is also given. The contact stress is obtained for a series of numerical examples. In the direct adhesion case the contact stress becomes infinite at the stiffener ends with a typical square root singularity for the continuum model, and behaving as a delta function for the membrane model. In the case of bonding through an adhesive layer the contact stress becomes finite and continuous along the entire contact area.
Advances in contact algorithms and their application to tires
NASA Technical Reports Server (NTRS)
Noor, Ahmed K.; Tanner, John A.
1988-01-01
Currently used techniques for tire contact analysis are reviewed. Discussion focuses on the different techniques used in modeling frictional forces and the treatment of contact conditions. A status report is presented on a new computational strategy for the modeling and analysis of tires, including the solution of the contact problem. The key elements of the proposed strategy are: (1) use of semianalytic mixed finite elements in which the shell variables are represented by Fourier series in the circumferential direction and piecewise polynomials in the meridional direction; (2) use of perturbed Lagrangian formulation for the determination of the contact area and pressure; and (3) application of multilevel iterative procedures and reduction techniques to generate the response of the tire. Numerical results are presented to demonstrate the effectiveness of a proposed procedure for generating the tire response associated with different Fourier harmonics.
Jeffries, D J; Donkor, S; Brookes, R H; Fox, A; Hill, P C
2004-09-01
The data requirements of a large multidisciplinary tuberculosis case contact study are complex. We describe an ACCESS-based relational database system that meets our rigorous requirements for data entry and validation, while being user-friendly, flexible, exportable, and easy to install on a network or stand alone system. This includes the development of a double data entry package for epidemiology and laboratory data, semi-automated entry of ELISPOT data directly from the plate reader, and a suite of new programmes for the manipulation and integration of flow cytometry data. The double entered epidemiology and immunology databases are combined into a separate database, providing a near-real-time analysis of immuno-epidemiological data, allowing important trends to be identified early and major decisions about the study to be made and acted on. This dynamic data management model is portable and can easily be applied to other studies.
Design and control of six degree-of-freedom active vibration isolation table.
Hong, Jinpyo; Park, Kyihwan
2010-03-01
A six-axis active vibration isolation system (AVIS) is designed by using the direct driven guide and ball contact mechanisms in order to have no cross-coupling between actuators. The point contact configuration gives an advantage of having an easy assembly of eight voice coil actuators to an upper and a base plate. A voice coil actuator is used since it can provide a large displacement and sufficient bandwidth required for vibration control. The AVIS is controlled considering the effect of flexible vibration mode in the upper plate and velocity sensor dynamics. A loop shaping technique and phase margin condition are applied to design a vibration controller. The performances of the AVIS are investigated in the frequency domain and finally validated by comparing with the passive isolation system. The scanning profiles of the specimen are compared together by using the atomic force microscope. The robustness of the AVIS is verified by showing the impulse response.
Design and control of six degree-of-freedom active vibration isolation table
NASA Astrophysics Data System (ADS)
Hong, Jinpyo; Park, Kyihwan
2010-03-01
A six-axis active vibration isolation system (AVIS) is designed by using the direct driven guide and ball contact mechanisms in order to have no cross-coupling between actuators. The point contact configuration gives an advantage of having an easy assembly of eight voice coil actuators to an upper and a base plate. A voice coil actuator is used since it can provide a large displacement and sufficient bandwidth required for vibration control. The AVIS is controlled considering the effect of flexible vibration mode in the upper plate and velocity sensor dynamics. A loop shaping technique and phase margin condition are applied to design a vibration controller. The performances of the AVIS are investigated in the frequency domain and finally validated by comparing with the passive isolation system. The scanning profiles of the specimen are compared together by using the atomic force microscope. The robustness of the AVIS is verified by showing the impulse response.
Suspension system for a wheel rolling on a flat track. [bearings for directional antennas
NASA Technical Reports Server (NTRS)
Mcginness, H. D. (Inventor)
1981-01-01
An improved suspension system for an uncrowned wheel rolling on a flat track is presented. It is characterized by a wheel frame assembly including a wheel frame and at least one uncrowned wheel connected in supporting relation with the frame. It is adapted to be seated in rolling engagement with a flat track, a load supporting bed, and a plurality of flexural struts interconnecting the bed in supported relation with the frame. Each of said struts is disposed in a plane passing through the center of the uncrowned wheel surface along a line substantially bisecting the line of contact established between the wheel surface and the flat surface of the truck and characterized by a modulus of elasticity sufficient for maintaining the axis of rotation for the wheel in substantial parallelism with the line of contact established between the surfaces of the wheel and track.
Clamshell closure for metal drum
Blanton, Paul S
2014-09-30
Closure ring to retain a lid in contact with a metal drum in central C-section conforming to the contact area between a lid and the rim of a drum and further having a radially inwardly directed flange and a vertically downwardly directed flange attached to the opposite ends of the C-section. The additional flanges reinforce the top of the drum by reducing deformation when the drum is dropped and maintain the lid in contact with the drum. The invention is particularly valuable in transportation and storage of fissile material.
Yi, He; Bao, Xin-Yu; Tiberio, Richard; Wong, H-S Philip
2015-02-11
Directed self-assembly (DSA) is a promising lithography candidate for technology nodes beyond 14 nm. Researchers have shown contact hole patterning for random logic circuits using DSA with small physical templates. This paper introduces an alphabet approach that uses a minimal set of small physical templates to pattern all contacts configurations on integrated circuits. We illustrate, through experiments, a general and scalable template design strategy that links the DSA material properties to the technology node requirements.
Dynamics of viscous liquid bridges inside microchannels subject to external oscillatory flow
NASA Astrophysics Data System (ADS)
Ahmadlouydarab, Majid; Azaiez, Jalel; Chen, Zhangxin
2015-02-01
We report on two-dimensional simulations of liquid bridges' dynamics inside microchannels of uniform wettability and subject to an external oscillatory flow rate. The oscillatory flow results in a zero net flow rate and its effects are compared to those of a stationary system. To handle the three phase contact lines motion, Cahn-Hilliard diffuse-interface formulation was used and the flow equations were solved using the finite element method with adaptively refined unstructured grids. The results indicate that the liquid bridge responds in three different ways depending on the substrate wettability properties and the frequency of the oscillatory flow. In particular below a critical frequency, the liquid bridge will rupture when the channel walls are philic or detach from the surface when they are phobic. However, at high frequencies, the liquid bridge shows a perpetual periodic oscillatory motion for both philic and phobic surfaces. Furthermore, an increase in the frequency of the flow velocity results in stabilization effects and a behavior approaching that of the stationary system where no rupture or detachment can be observed. This stable behavior is the direct result of less deformation of the liquid bridge due to the fast flow direction change and motion of contact lines on the solid substrate. Moreover, it was found that the flow velocity is out of phase with the footprint and throat lengths and that the latter two also show a phase difference. These differences were explained in terms of the motion of the two contact lines on the solid substrates and the deformation of the two fluid-fluid interfaces.
Dynamics of viscous liquid bridges inside microchannels subject to external oscillatory flow.
Ahmadlouydarab, Majid; Azaiez, Jalel; Chen, Zhangxin
2015-02-01
We report on two-dimensional simulations of liquid bridges' dynamics inside microchannels of uniform wettability and subject to an external oscillatory flow rate. The oscillatory flow results in a zero net flow rate and its effects are compared to those of a stationary system. To handle the three phase contact lines motion, Cahn-Hilliard diffuse-interface formulation was used and the flow equations were solved using the finite element method with adaptively refined unstructured grids. The results indicate that the liquid bridge responds in three different ways depending on the substrate wettability properties and the frequency of the oscillatory flow. In particular below a critical frequency, the liquid bridge will rupture when the channel walls are philic or detach from the surface when they are phobic. However, at high frequencies, the liquid bridge shows a perpetual periodic oscillatory motion for both philic and phobic surfaces. Furthermore, an increase in the frequency of the flow velocity results in stabilization effects and a behavior approaching that of the stationary system where no rupture or detachment can be observed. This stable behavior is the direct result of less deformation of the liquid bridge due to the fast flow direction change and motion of contact lines on the solid substrate. Moreover, it was found that the flow velocity is out of phase with the footprint and throat lengths and that the latter two also show a phase difference. These differences were explained in terms of the motion of the two contact lines on the solid substrates and the deformation of the two fluid-fluid interfaces.
Pan, Li; Zhang, Zhongwang; Lv, Jianliang; Zhou, Peng; Hu, Wenfa; Fang, Yuzhen; Chen, Haotai; Liu, Xinsheng; Shao, Junjun; Zhao, Furong; Ding, Yaozhong; Lin, Tong; Chang, Huiyun; Zhang, Jie; Zhang, Yongguang; Wang, Yonglu
2014-01-01
The aim of this study was to enhance specific mucosal, systemic, and cell-mediated immunity and to induce earlier onset of protection against direct-contact challenge in cattle by intranasal delivery of a nanoparticle-based nasal vaccine against type A foot-and-mouth disease (FMD). In this study, two kinds of nanoparticle-based nasal vaccines against type A FMD were designed: (1) chitosan-coated poly(lactic-co-glycolic acid) (PLGA) loaded with plasmid DNA (Chi-PLGA-DNA) and (2) chitosan-trehalose and inactivated foot-and-mouth disease virus (FMDV) (Chi-Tre-Inactivated). Cattle were immunized by an intranasal route with nanoparticles and then challenged for 48 hours by direct contact with two infected donor cattle per pen. Donors were inoculated intradermally in the tongue 48 hours before challenge, with 0.2 mL cattle-passaged FMDV. Serological and mucosal antibody responses were evaluated, and virus excretion and the number of contact infections were quantified. FMDV-specific secretory immunoglobulin (Ig)A (sIgA) antibodies in nasal washes were initially detected at 4 days postvaccination (dpv) with two kinds of nanoparticles. The highest levels of sIgA expression were observed in nasal washes, at 10 dpv, from animals with Chi-PLGA-DNA nanoparticles, followed by animals immunized once by intranasal route with a double dose of Chi-Tre-Inactivated nanoparticles and animals immunized by intranasal route three times with Chi-Tre-Inactivated nanoparticles (P<0.05). FMDV-specific IgA antibodies in serum showed a similar pattern. All animals immunized by intranasal route developed low levels of detectable IgG in serum at 10 dpv. Following stimulation with FMDV, the highest levels of proliferation were observed in splenocytes harvested from Chi-PLGA-DNA-immunized animals, followed by proliferation of cells harvested from Chi-Tre-Inactivated nanoparticle-immunized animals (P<0.05). Higher protection rates were associated with the highest sIgA antibody responses induced in the Chi-PLGA-DNA nanoparticle-immunized group. Only one animal was clinically affected with mild signs after 7 days of contact challenge, after a delay of 2–3 days compared with the clinically affected negative-control group. Of the five animals directly challenged that were vaccinated by intranasal route with a double dose of Chi-Tre-Inactivated, four were clinically infected; however, the degree of severity of disease in this group was lower than in control cattle. The number of viral RNA copies in nasal swabs from the vaccinated, severely infected group was significantly higher than in swabs from the vaccinated, clinically protected group. These data suggested that intranasal delivery of Chi-PLGA-DNA nanoparticles resulted in higher levels of mucosal, systemic, and cell-mediated immunity than did of Chi-Tre-Inactivated nanoparticles. In conclusion, although intranasal delivery with FMDV antigen mediated by nanoparticles did not provide complete clinical protection, it reduced disease severity and virus excretion and delayed clinical symptoms. Chi-PLGA-DNA nanoparticle vaccines have potential as a nasal delivery system for vaccines. PMID:25506214
Scanziani, Alessio; Singh, Kamaljit; Blunt, Martin J; Guadagnini, Alberto
2017-06-15
Multiphase flow in porous media is strongly influenced by the wettability of the system, which affects the arrangement of the interfaces of different phases residing in the pores. We present a method for estimating the effective contact angle, which quantifies the wettability and controls the local capillary pressure within the complex pore space of natural rock samples, based on the physical constraint of constant curvature of the interface between two fluids. This algorithm is able to extract a large number of measurements from a single rock core, resulting in a characteristic distribution of effective in situ contact angle for the system, that is modelled as a truncated Gaussian probability density distribution. The method is first validated on synthetic images, where the exact angle is known analytically; then the results obtained from measurements within the pore space of rock samples imaged at a resolution of a few microns are compared to direct manual assessment. Finally the method is applied to X-ray micro computed tomography (micro-CT) scans of two Ketton cores after waterflooding, that display water-wet and mixed-wet behaviour. The resulting distribution of in situ contact angles is characterized in terms of a mixture of truncated Gaussian densities. Crown Copyright © 2017. Published by Elsevier Inc. All rights reserved.
Chen, Szu-Ying; Kaufman, Yair; Schrader, Alex M; Seo, Dongjin; Lee, Dong Woog; Page, Steven H; Koenig, Peter H; Isaacs, Sandra; Gizaw, Yonas; Israelachvili, Jacob N
2017-09-26
Measuring truly equilibrium adhesion energies or contact angles to obtain the thermodynamic values is experimentally difficult because it requires loading/unloading or advancing/receding boundaries to be measured at rates that can be slower than 1 nm/s. We have measured advancing-receding contact angles and loading-unloading adhesion energies for various systems and geometries involving molecularly smooth and chemically homogeneous surfaces moving at different but steady velocities in both directions, ±V, focusing on the thermodynamic limit of ±V → 0. We have used the Bell Theory (1978) to derive expressions for the dynamic (velocity-dependent) adhesion energies and contact angles suitable for both (i) dynamic adhesion measurements using the classic Johnson-Kendall-Roberts (JKR, 1971) theory of "contact mechanics" and (ii) dynamic contact angle hysteresis measurements of both rolling droplets and syringe-controlled (sessile) droplets on various surfaces. We present our results for systems that exhibited both steady and varying velocities from V ≈ 10 mm/s to 1 nm/s, where in all cases but one, the advancing (V > 0) and receding (V < 0) adhesion energies and/or contact angles converged toward the same theoretical (thermodynamic) values as V → 0. Our equations for the dynamic contact angles are similar to the classic equations of Blake & Haynes (1969) and fitted the experimental adhesion data equally well over the range of velocities studied, although with somewhat different fitting parameters for the characteristic molecular length/dimension or area and characteristic bond formation/rupture lifetime or velocity. Our theoretical and experimental methods and results unify previous kinetic theories of adhesion and contact angle hysteresis and offer new experimental methods for testing kinetic models in the thermodynamic, quasi-static, limit. Our analyses are limited to kinetic effects only, and we conclude that hydrodynamic, i.e., viscous, and inertial effects do not play a role at the interfacial velocities of our experiments, i.e., V < (1-10) mm/s (for water and hexadecane, but for viscous polymers it may be different), consistent with previously reported studies.
Time Service Dept., United States Naval Observatory
Features What Time is it? USNO Master Clock Cesium Fountain Linear Ion Trap GPS Satellite Time Transfer Network Time Service Telephone Time US Time Zones Systems of Time Leap Seconds Highlights Daily Home ntp.org Contact the USNO The Sky This Week Sun Rise/Set Tour Info Travel Directions Department of
Code of Federal Regulations, 2011 CFR
2011-01-01
... come into direct contact with uranium metal vapor or liquid or with process gas consisting of UF6 or a mixture of UF6 and other gases: (1) Uranium vaporization systems (AVLIS). Especially designed or prepared... laser-based enrichment items, the materials resistant to corrosion by the vapor or liquid of uranium...
Code of Federal Regulations, 2014 CFR
2014-01-01
... come into direct contact with uranium metal vapor or liquid or with process gas consisting of UF6 or a mixture of UF6 and other gases: (1) Uranium vaporization systems (AVLIS). Especially designed or prepared... laser-based enrichment items, the materials resistant to corrosion by the vapor or liquid of uranium...
Code of Federal Regulations, 2013 CFR
2013-01-01
... come into direct contact with uranium metal vapor or liquid or with process gas consisting of UF6 or a mixture of UF6 and other gases: (1) Uranium vaporization systems (AVLIS). Especially designed or prepared... laser-based enrichment items, the materials resistant to corrosion by the vapor or liquid of uranium...
Code of Federal Regulations, 2012 CFR
2012-01-01
... come into direct contact with uranium metal vapor or liquid or with process gas consisting of UF6 or a mixture of UF6 and other gases: (1) Uranium vaporization systems (AVLIS). Especially designed or prepared... laser-based enrichment items, the materials resistant to corrosion by the vapor or liquid of uranium...
Code of Federal Regulations, 2010 CFR
2010-01-01
... come into direct contact with uranium metal vapor or liquid or with process gas consisting of UF6 or a mixture of UF6 and other gases: (1) Uranium vaporization systems (AVLIS). Especially designed or prepared... laser-based enrichment items, the materials resistant to corrosion by the vapor or liquid of uranium...
Leung, Ka-Ngo; Gordon, K.C.; Kippenhan, D.O.; Purgalis, P.; Moussa, D.; Williams, M.D.; Wilde, S.B.; West, M.W.
1987-10-16
A large area directly heated lanthanum hexaboride (LaB/sub 6/) cathode system is disclosed. The system comprises a LaB/sub 6/ cathode element generally circular in shape about a central axis. The cathode element has a head with an upper substantially planar emission surface, and a lower downwardly and an intermediate body portion which diminishes in cross-section from the head towards the base of the cathode element. A central rod is connected to the base of the cathode element and extends along the central axis. Plural upstanding spring fingers are urged against an outer peripheral contact surface of the head end to provide a mechanical and electrical connection to the cathode element. 7 figs
Interfacial thermal resistance and thermal rectification in carbon nanotube film-copper systems.
Duan, Zheng; Liu, Danyang; Zhang, Guang; Li, Qingwei; Liu, Changhong; Fan, Shoushan
2017-03-02
Thermal rectification occurring at interfaces is an important research area, which contains deep fundamental physics and has extensive application prospects. In general, the measurement of interfacial thermal rectification is based on measuring interfacial thermal resistance (ITR). However, ITRs measured via conventional methods cannot avoid extra thermal resistance asymmetry due to the contact between the sample and the thermometer. In this study, we employed a non-contact infrared thermal imager to monitor the temperature of super-aligned carbon nanotube (CNT) films and obtain the ITRs between the CNT films and copper. The ITRs along the CNT-copper direction and the reverse direction are in the ranges of 2.2-3.6 cm 2 K W -1 and 9.6-11.9 cm 2 K W -1 , respectively. The obvious difference in the ITRs of the two directions shows a significant thermal rectification effect, and the rectifying coefficient ranges between 0.57 and 0.68. The remarkable rectification factor is extremely promising for the manufacture of thermal transistors with a copper/CNT/copper structure and further thermal logic devices. Moreover, our method could be extended to other 2-dimensional materials, such as graphene and MoS 2 , for further explorations.
Direct Numerical Simulation of Fingering Instabilities in Coating Flows
NASA Astrophysics Data System (ADS)
Eres, Murat H.; Schwartz, Leonard W.
1998-11-01
We consider stability and finger formation in free surface flows. Gravity driven downhill drainage and temperature gradient driven climbing flows are two examples of such problems. The former situation occurs when a mound of viscous liquid on a vertical wall is allowed to flow. Constant surface shear stress due to temperature gradients (Marangoni stress) can initiate the latter problem. The evolution equations are derived using the lubrication approximation. We also include the effects of finite-contact angles in the evolution equations using a disjoining pressure model. Evolution equations for both problems are solved using an efficient alternating-direction-implicit method. For both problems a one-dimensional base state is established, that is steady in a moving reference frame. This base state is unstable to transverse perturbations. The transverse wavenumbers for the most rapidly growing modes are found through direct numerical solution of the nonlinear evolution equations, and are compared with published experimental results. For a range of finite equilibrium contact angles, the fingers can grow without limit leading to semi-finite steady fingers in a moving coordinate system. A computer generated movie of the nonlinear simulation results, for several sets of input parameters, will be shown.
Are diverse societies less cohesive? Testing contact and mediated contact theories.
McKenna, Sarah; Lee, Eunro; Klik, Kathleen A; Markus, Andrew; Hewstone, Miles; Reynolds, Katherine J
2018-01-01
Previous research has demonstrated that there is a negative relationship between ethnic diversity in a local community and social cohesion. Often the way social cohesion is assessed, though, varies across studies and only some aspects of the construct are included (e.g., trust). The current research explores the relationship between diversity and social cohesion across a number of indicators of social cohesion including neighbourhood social capital, safety, belonging, generalized trust, and volunteering. Furthermore, social psychological theories concerning the role of positive contact and its impact on feelings of threat are investigated. Using a sample of 1070 third generation 'majority' Australians and structural equation modelling (SEM), findings suggest ethnic diversity is related to positive intergroup contact, and that contact showed beneficial impacts for some indicators of social cohesion both directly and indirectly through reducing perceived threat. When interethnic contact and perceived threat are included in the model there is no direct negative effect between diversity and social cohesion. The theoretical implications of these findings are outlined including the importance of facilitating opportunities for positive contact in diverse communities.
Are diverse societies less cohesive? Testing contact and mediated contact theories
Lee, Eunro; Klik, Kathleen A.; Markus, Andrew; Hewstone, Miles; Reynolds, Katherine J.
2018-01-01
Previous research has demonstrated that there is a negative relationship between ethnic diversity in a local community and social cohesion. Often the way social cohesion is assessed, though, varies across studies and only some aspects of the construct are included (e.g., trust). The current research explores the relationship between diversity and social cohesion across a number of indicators of social cohesion including neighbourhood social capital, safety, belonging, generalized trust, and volunteering. Furthermore, social psychological theories concerning the role of positive contact and its impact on feelings of threat are investigated. Using a sample of 1070 third generation ‘majority’ Australians and structural equation modelling (SEM), findings suggest ethnic diversity is related to positive intergroup contact, and that contact showed beneficial impacts for some indicators of social cohesion both directly and indirectly through reducing perceived threat. When interethnic contact and perceived threat are included in the model there is no direct negative effect between diversity and social cohesion. The theoretical implications of these findings are outlined including the importance of facilitating opportunities for positive contact in diverse communities. PMID:29596501
Ferromagnetic tunnel contacts to graphene: Contact resistance and spin signal
DOE Office of Scientific and Technical Information (OSTI.GOV)
Cubukcu, M.; Laczkowski, P.; Vergnaud, C.
2015-02-28
We report spin transport in CVD graphene-based lateral spin valves using different magnetic contacts. We compared the spin signal amplitude measured on devices where the cobalt layer is directly in contact with the graphene to the one obtained using tunnel contacts. Although a sizeable spin signal (up to ∼2 Ω) is obtained with direct contacts, the signal is strongly enhanced (∼400 Ω) by inserting a tunnel barrier. In addition, we studied the resistance-area product (R.A) of a variety of contacts on CVD graphene. In particular, we compared the R.A products of alumina and magnesium oxide tunnel barriers grown by sputteringmore » deposition of aluminum or magnesium and subsequent natural oxidation under pure oxygen atmosphere or by plasma. When using an alumina tunnel barrier on CVD graphene, the R.A product is high and exhibits a large dispersion. This dispersion can be highly reduced by using a magnesium oxide tunnel barrier, as for the R.A value. This study gives insight in the material quest for reproducible and efficient spin injection in CVD graphene.« less
49 CFR 393.136 - What are the rules for securing large boulders?
Code of Federal Regulations, 2010 CFR
2010-10-01
...-separated points of contact that prevent its tendency to roll in any direction. (5) If a boulder is tapered...) Only chain may be used as tiedowns to secure large boulders. (2) Tiedowns which are in direct contact... boulder. Whenever practicable, the angle of the chains must not exceed 45 degrees from the horizontal. ...
Post-Adoption Face-to-Face Contact with Birth Parents: Prospective Adopters' Views
ERIC Educational Resources Information Center
Turkington, Selina; Taylor, Brian J.
2009-01-01
The trend in adoption since the 1960s has been away from secrecy and towards greater openness; contact through an intermediary, and direct contact by letter, is now widely accepted. More controversial is the challenge of face-to-face contact with birth parents, and social workers involved in the decision-making process find themselves having to…
Development of a Contact Permeation Test Fixture and Method
2013-04-01
direct contact with the skin, indicates the need for a quantitative contact test method. Comparison tests were conducted with VX on a standardized...Guide for the Care and Use of Laboratory Animals (8th ed.; National Research Council: Washington, DC, 2011). This test was also performed in...1 1.2 Development of a Contact-Based Permeation Test Method ........................................ 1 2. EXPERIMENTAL PROCEDURES
Behavior of a Liquid Bridge between Nonparallel Hydrophobic Surfaces.
Ataei, Mohammadmehdi; Chen, Huanchen; Amirfazli, Alidad
2017-12-26
When a liquid bridge is formed between two nonparallel identical surfaces, it can move along the surfaces. Literature indicates that the direction of bridge movement is governed by the wettability of surfaces. When the surfaces are hydrophilic, the motion of the bridge is always toward the cusp (intersection of the plane of the two bounding surfaces). On the other hand, the movement is hitherto thought to be always pointing away from the cusp when the surfaces are hydrophobic. In this study, through experiments, numerical simulations, and analytical reasoning, we demonstrate that for hydrophobic surfaces, wettability is not the only factor determining the direction of the motion. A new geometrical parameter, i.e., confinement (cf), was defined as the ratio of the distance of the farthest contact point of the bridge to the cusp, and that of the closest contact point to the cusp. The direction of the motion depends on the amount of confinement (cf). When the distance between the surfaces is large (resulting in a small cf), the bridge tends to move toward the cusp through a pinning/depinning mechanism of contact lines. When the distance between the surfaces is small (large cf), the bridge tends to move away from the cusp. For a specific system, a maximum cf value (cf max ) exists. A sliding behavior (i.e., simultaneous advancing on the wider side and receding on the narrower side) can also be seen when a liquid bridge is compressed such that the cf exceeds the cf max . Contact angle hysteresis (CAH) is identified as an underpinning phenomenon that together with cf fundamentally explains the movement of a trapped liquid between two hydrophobic surfaces. If there is no CAH, however, i.e., the case of ideal hydrophobic surfaces, the cf will be a constant; we show that the bridge slides toward the cusp when it is stretched, while it slides away from the cusp when it is compressed (note sliding motion is different from motion due to pinning/depinning mechanism of contact lines). As such, the displacement is only related to geometrical parameters such as the amount of compression (or stretching) and the dihedral angle between the surfaces.
In situ electronic probing of semiconducting nanowires in an electron microscope.
Fauske, V T; Erlbeck, M B; Huh, J; Kim, D C; Munshi, A M; Dheeraj, D L; Weman, H; Fimland, B O; Van Helvoort, A T J
2016-05-01
For the development of electronic nanoscale structures, feedback on its electronic properties is crucial, but challenging. Here, we present a comparison of various in situ methods for electronically probing single, p-doped GaAs nanowires inside a scanning electron microscope. The methods used include (i) directly probing individual as-grown nanowires with a sharp nano-manipulator, (ii) contacting dispersed nanowires with two metal contacts and (iii) contacting dispersed nanowires with four metal contacts. For the last two cases, we compare the results obtained using conventional ex situ litho-graphy contacting techniques and by in situ, direct-write electron beam induced deposition of a metal (Pt). The comparison shows that 2-probe measurements gives consistent results also with contacts made by electron beam induced deposition, but that for 4-probe, stray deposition can be a problem for shorter nanowires. This comparative study demonstrates that the preferred in situ method depends on the required throughput and reliability. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.
Dynamic Contact Angle at the Nanoscale: A Unified View.
Lukyanov, Alex V; Likhtman, Alexei E
2016-06-28
Generation of a dynamic contact angle in the course of wetting is a fundamental phenomenon of nature. Dynamic wetting processes have a direct impact on flows at the nanoscale, and therefore, understanding them is exceptionally important to emerging technologies. Here, we reveal the microscopic mechanism of dynamic contact angle generation. It has been demonstrated using large-scale molecular dynamics simulations of bead-spring model fluids that the main cause of local contact angle variations is the distribution of microscopic force acting at the contact line region. We were able to retrieve this elusive force with high accuracy. It has been directly established that the force distribution can be solely predicted on the basis of a general friction law for liquid flow at solid surfaces by Thompson and Troian. The relationship with the friction law provides both an explanation of the phenomenon of dynamic contact angle and a methodology for future predictions. The mechanism is intrinsically microscopic, universal, and irreducible and is applicable to a wide range of problems associated with wetting phenomena.
Sherlekar, Amrita L; Janssen, Abbey; Siehr, Meagan S; Koo, Pamela K; Caflisch, Laura; Boggess, May; Lints, Robyn
2013-01-01
Mating behaviors in simple invertebrate model organisms represent tractable paradigms for understanding the neural bases of sex-specific behaviors, decision-making and sensorimotor integration. However, there are few examples where such neural circuits have been defined at high resolution or interrogated. Here we exploit the simplicity of the nematode Caenorhabditis elegans to define the neural circuits underlying the male's decision to initiate mating in response to contact with a mate. Mate contact is sensed by male-specific sensilla of the tail, the rays, which subsequently induce and guide a contact-based search of the hermaphrodite's surface for the vulva (the vulva search). Atypically, search locomotion has a backward directional bias so its implementation requires overcoming an intrinsic bias for forward movement, set by activity of the sex-shared locomotory system. Using optogenetics, cell-specific ablation- and mutant behavioral analyses, we show that the male makes this shift by manipulating the activity of command cells within this sex-shared locomotory system. The rays control the command interneurons through the male-specific, decision-making interneuron PVY and its auxiliary cell PVX. Unlike many sex-shared pathways, PVY/PVX regulate the command cells via cholinergic, rather than glutamatergic transmission, a feature that likely contributes to response specificity and coordinates directional movement with other cholinergic-dependent motor behaviors of the mating sequence. PVY/PVX preferentially activate the backward, and not forward, command cells because of a bias in synaptic inputs and the distribution of key cholinergic receptors (encoded by the genes acr-18, acr-16 and unc-29) in favor of the backward command cells. Our interrogation of male neural circuits reveals that a sex-specific response to the opposite sex is conferred by a male-specific pathway that renders subordinate, sex-shared motor programs responsive to mate cues. Circuit modifications of these types may make prominent contributions to natural variations in behavior that ultimately bring about speciation.
Sherlekar, Amrita L.; Janssen, Abbey; Siehr, Meagan S.; Koo, Pamela K.; Caflisch, Laura; Boggess, May; Lints, Robyn
2013-01-01
Background Mating behaviors in simple invertebrate model organisms represent tractable paradigms for understanding the neural bases of sex-specific behaviors, decision-making and sensorimotor integration. However, there are few examples where such neural circuits have been defined at high resolution or interrogated. Methodology/Principal Findings Here we exploit the simplicity of the nematode Caenorhabditis elegans to define the neural circuits underlying the male’s decision to initiate mating in response to contact with a mate. Mate contact is sensed by male-specific sensilla of the tail, the rays, which subsequently induce and guide a contact-based search of the hermaphrodite’s surface for the vulva (the vulva search). Atypically, search locomotion has a backward directional bias so its implementation requires overcoming an intrinsic bias for forward movement, set by activity of the sex-shared locomotory system. Using optogenetics, cell-specific ablation- and mutant behavioral analyses, we show that the male makes this shift by manipulating the activity of command cells within this sex-shared locomotory system. The rays control the command interneurons through the male-specific, decision-making interneuron PVY and its auxiliary cell PVX. Unlike many sex-shared pathways, PVY/PVX regulate the command cells via cholinergic, rather than glutamatergic transmission, a feature that likely contributes to response specificity and coordinates directional movement with other cholinergic-dependent motor behaviors of the mating sequence. PVY/PVX preferentially activate the backward, and not forward, command cells because of a bias in synaptic inputs and the distribution of key cholinergic receptors (encoded by the genes acr-18, acr-16 and unc-29) in favor of the backward command cells. Conclusion/Significance Our interrogation of male neural circuits reveals that a sex-specific response to the opposite sex is conferred by a male-specific pathway that renders subordinate, sex-shared motor programs responsive to mate cues. Circuit modifications of these types may make prominent contributions to natural variations in behavior that ultimately bring about speciation. PMID:23577128
Anisotropic frictional heat dissipation in cyclotrimethylene trinitramine
NASA Astrophysics Data System (ADS)
Rajak, Pankaj; Kalia, Rajiv; Nakano, Aiichiro; Vashishta, Priya
Anisotropic frictional response and corresponding heat dissipation from different crystallographic planes of RDX crystal is studied using molecular dynamics simulations. The effect of frictional force on the nature of damage and system temperature is monitored along different directions on primary slip plane, (010), of RDX and on non-slip planes, (100) and (001). The correlation between the friction coefficient, deformation and the frictional heating in these system is determined. It is observed that friction coefficients on slip planes are smaller than those of non-slip planes. In response to friction on slip plane, RDX crystal deforms via dislocation formation and shows less heating. On non-slip planes due to the inability of the system to deform by dislocation formation, large temperature rise is observed in the system just below the contact area of two surfaces. Frictional sliding on non-slip planes also lead to the formation of damage zone just below the contact area of two surfaces due to the change in RDX ring conformation from chair to boat/half-boat. This research is supported by the AFOSR Grant: FA9550-16- 1-0042.
Motion of Drops on Surfaces with Wettability Gradients
NASA Technical Reports Server (NTRS)
Subramanian, R. Shankar; McLaughlin, John B.; Moumen, Nadjoua; Qian, Dongying
2002-01-01
A liquid drop present on a solid surface can move because of a gradient in wettability along the surface, as manifested by a gradient in the contact angle. The contact angle at a given point on the contact line between a solid and a liquid in a gaseous medium is the angle between the tangent planes to the liquid and the solid surfaces at that point and is measured within the liquid side, by convention. The motion of the drop occurs in the direction of increasing wettability. The cause of the motion is the net force exerted on the drop by the solid surface because of the variation of the contact angle around the periphery. This force causes acceleration of an initially stationary drop, and leads to its motion in the direction of decreasing contact angle. The nature of the motion is determined by the balance between the motivating force and the resisting hydrodynamic force from the solid surface and the surrounding gaseous medium. A wettability gradient can be chemically induced as shown by Chaudhury and Whitesides who provided unambiguous experimental evidence that drops can move in such gradients. The phenomenon can be important in heat transfer applications in low gravity, such as when condensation occurs on a surface. Daniel et al have demonstrated that the velocity of a drop on a surface due to a wettability gradient in the presence of condensation can be more than two orders of magnitude larger than that observed in the absence of condensation. In the present research program, we have begun to study the motion of a drop in a wettability gradient systematically using a model system. Our initial efforts will be restricted to a system in which no condensation occurs. The experiments are performed as follows. First, a rectangular strip of approximate dimensions 10 x 20 mm is cut out of a silicon wafer. The strip is cleaned thoroughly and its surface is exposed to the vapor from an alkylchlorosilane for a period lasting between one and two minutes inside a desiccator. This is done using an approximate line source of the vapor in the form of a string soaked in the alkylchlorosilane. Ordinarily, many fluids, including water, wet the surface of silicon quite well. This means that the contact angle is small. But the silanized surface resists wetting, with contact angles that are as large as 100 degs. Therefore, a gradient of wettability is formed on the silicon surface. The region near the string is highly hydrophobic, and the contact angle decreases gradually toward a small value at the hydrophilic end away from this region. The change in wettability occurs over a distance of several mm. The strip is placed on a platform within a Plexiglas cell. Drops of a suitable liquid are introduced on top of the strip near the hydrophobic end. An optical system attached to a video camera is trained on the drop so that images of the moving drop can be captured on videotape for subsequent analysis. We have performed preliminary experiments with water as well as ethylene glycol drops. Results from these experiments will be presented in the poster. Future plans include the refinement of the experimental system so as to permit images to be recorded from the side as well as the top, and the conduct of a systematic study in which the drop size is varied over a good range. Experiments will be conducted with different fluids so as to obtain the largest possible range of suitably defined Reynolds and Capillary numbers. Also, an effort will be initiated on theoretical modeling of this motion. The challenges in the development of the theoretical description lie in the proper analysis of the region in the vicinity of the contact line, as well as in the free boundary nature of the problem. It is known that continuum models assuming the no slip condition all the way to the contact line fail by predicting that the stress on the solid surface becomes singular as the contact line is approached. One approach for dealing with this issue has been to relax the no-slip boundary condition using the Navier model. Molecular dynamics simulations of the contact line region show that for a non-polar liquid on a solid surface, the no-slip boundary condition is in fact incorrect near the contact line. Furthermore, the same simulations also show that the usual relationship between stress and the rate of deformation breaks down in the vicinity of the contact line. In developing continuum theoretical models of the system, we shall accommodate this knowledge to the extent possible.
Data reliability in complex directed networks
NASA Astrophysics Data System (ADS)
Sanz, Joaquín; Cozzo, Emanuele; Moreno, Yamir
2013-12-01
The availability of data from many different sources and fields of science has made it possible to map out an increasing number of networks of contacts and interactions. However, quantifying how reliable these data are remains an open problem. From Biology to Sociology and Economics, the identification of false and missing positives has become a problem that calls for a solution. In this work we extend one of the newest, best performing models—due to Guimerá and Sales-Pardo in 2009—to directed networks. The new methodology is able to identify missing and spurious directed interactions with more precision than previous approaches, which renders it particularly useful for analyzing data reliability in systems like trophic webs, gene regulatory networks, communication patterns and several social systems. We also show, using real-world networks, how the method can be employed to help search for new interactions in an efficient way.
NASA Astrophysics Data System (ADS)
Van Hove, Marleen; Posthuma, Niels; Geens, Karen; Wellekens, Dirk; Li, Xiangdong; Decoutere, Stefaan
2018-04-01
p-GaN gate enhancement mode power transistors were processed in a Si CMOS processing line on 200 mm Si(111) substrates using Au-free metallization schemes. Si/Ti/Al/Ti/TiN ohmic contacts were formed after full recessing of the AlGaN barrier, followed by a HCl-based wet cleaning step. The electrical performance of devices aligned to the [11\\bar{2}0] and the perpendicular [1\\bar{1}00] directions was compared. The ohmic contact resistance was decreased from 1 Ω·mm for the [11\\bar{2}0] direction to 0.35 Ω·mm for the [1\\bar{1}00] direction, resulting in an increase of the drain saturation current from 0.5 to 0.6 A/mm, and a reduction of the on-resistance from 6.4 to 5.1 Ω·mm. Moreover, wafer mapping of the device characteristics over the 200 mm wafer showed a tighter statistical distribution for the [1\\bar{1}00] direction. However, by using an optimized sulfuric/ammonia peroxide (SPM/APM) cleaning step, the ohmic contact resistance could be lowered to 0.3 Ω·mm for both perpendicular directions.
Time to contact and the control of manual prehension.
Watson, M K; Jakobson, L S
1997-11-01
In the present study, a kinematic analysis was made of unconstrained, natural prehension movements directed toward an object approaching the observer on a conveyor belt at one of three constant velocities, from one of three different directions (head-on or along the fronto-parallel plane coming either from the subject's left or right). Subjects were required to grasp the object when it reached a target located 20 cm directly in front of the hand's start position. The kinematic analysis revealed that both the transport and grasp components of the movement changed in response to the experimental manipulations, but did so in a manner that guaranteed that, for objects approaching from a given direction, hand closure would begin at a constant time prior to object contact (regardless of the object's approach speed). The kinematic analysis also revealed, however, that the onset of hand closure began earlier with objects approaching from the right than from other directions -- an effect which would not be predicted if time to contact was the key variable controlling the onset of hand closure. These results, then, lend only partial support to the theory that temporal coordination between the transport and grasp components of prehension is ensured through their common dependence on time to contact information.
Classification of hand eczema.
Agner, T; Aalto-Korte, K; Andersen, K E; Foti, C; Gimenéz-Arnau, A; Goncalo, M; Goossens, A; Le Coz, C; Diepgen, T L
2015-12-01
Classification of hand eczema (HE) is mandatory in epidemiological and clinical studies, and also important in clinical work. The aim was to test a recently proposed classification system of HE in clinical practice in a prospective multicentre study. Patients were recruited from nine different tertiary referral centres. All patients underwent examination by specialists in dermatology and were checked using relevant allergy testing. Patients were classified into one of the six diagnostic subgroups of HE: allergic contact dermatitis, irritant contact dermatitis, atopic HE, protein contact dermatitis/contact urticaria, hyperkeratotic endogenous eczema and vesicular endogenous eczema, respectively. An additional diagnosis was given if symptoms indicated that factors additional to the main diagnosis were of importance for the disease. Four hundred and twenty-seven patients were included, 379 (89%) of the patients could be classified directly into one of the six diagnostic subgroups, with irritant and allergic contact dermatitis comprising 249 patients (58%). For 32 (7%) more than one of the six diagnostic subgroups had been formulated as a main diagnosis, and 16 (4%) could not be classified. 38% had one additional diagnosis and 26% had two or more additional diagnoses. Eczema on feet was found in 30% of the patients, statistically significantly more frequently associated with hyperkeratotic and vesicular endogenous eczema. We find that the classification system investigated in the present study was useful, being able to give an appropriate main diagnosis for 89% of HE patients, and for another 7% when using two main diagnoses. The fact that more than half of the patients had one or more additional diagnoses illustrates that HE is a multifactorial disease. © 2015 European Academy of Dermatology and Venereology.
Vibro-Perception of Optical Bio-Inspired Fiber-Skin.
Li, Tao; Zhang, Sheng; Lu, Guo-Wei; Sunami, Yuta
2018-05-12
In this research, based on the principle of optical interferometry, the Mach-Zehnder and Optical Phase-locked Loop (OPLL) vibro-perception systems of bio-inspired fiber-skin are designed to mimic the tactile perception of human skin. The fiber-skin is made of the optical fiber embedded in the silicone elastomer. The optical fiber is an instinctive and alternative sensor for tactile perception with high sensitivity and reliability, also low cost and susceptibility to the magnetic interference. The silicone elastomer serves as a substrate with high flexibility and biocompatibility, and the optical fiber core serves as the vibro-perception sensor to detect physical motions like tapping and sliding. According to the experimental results, the designed optical fiber-skin demonstrates the ability to detect the physical motions like tapping and sliding in both the Mach-Zehnder and OPLL vibro-perception systems. For direct contact condition, the OPLL vibro-perception system shows better performance compared with the Mach-Zehnder vibro-perception system. However, the Mach-Zehnder vibro-perception system is preferable to the OPLL system in the indirect contact experiment. In summary, the fiber-skin is validated to have light touch character and excellent repeatability, which is highly-suitable for skin-mimic sensing.
Dejak, Beata; Młotkowski, Andrzej
2015-03-01
Polymerization shrinkage of composites is one of the main causes of leakage around dental restorations. Despite the large numbers of studies there is no consensus, what kind of teeth reconstruction--direct or indirect composite restorations are the most beneficial and the most durable. The aim was to compare equivalent stresses and contact adhesive stresses in molar teeth with class II MOD cavities, which were restored with inlays and direct restorations (taking into account polymerization shrinkage of composite resin) during simulated mastication. The study was conducted using the finite elements method with the application of contact elements. Three 3D models of first molars were created: model A was an intact tooth; model B--a tooth with a composite inlay, and model C--a tooth with a direct composite restoration. Polymerization linear shrinkage 0.7% of a direct composite restoration and resin luting cement was simulated (load 1). A computer simulation of mastication was performed (load 2). In these 2 situations, equivalent stresses according to the modified von Mises criterion (mvM) in the materials of mandibular first molar models with different restorations were calculated and compared. Contact stresses in the luting cement-tooth tissue adhesive interface around the restorations were also assessed and analyzed. Equivalent stresses in a tooth with a direct composite restoration (the entire volume of which was affected by polymerization shrinkage) were many times higher than in the tooth restored with a composite inlay (where shrinkage was present only in a thin layer of the luting cement). In dentin and enamel the stress values were 8-14 times higher, and were 13 times higher in the direct restoration than in the inlay. Likewise, contact stresses in the adhesive bond around the direct restoration were 6.5-7.7 times higher compared to an extraorally cured restoration. In the masticatory simulation, shear contact stresses in the adhesive bond around the direct composite restoration reached the highest values 32.8 MPa and significantly exceeded the shear strength of the connection between the resin luting cement and the tooth structure. Equivalent stresses in the tooth structures restored with inlays and in the restoration material itself and contact stresses at the tooth-luting cement adhesive interface are many times lower compared to teeth with direct composite restorations. Teeth with indirect restorations are potentially less susceptible to damage compared to those with direct restorations. Composite inlays also ensure a better seal compared to direct restorations. Polymerization shrinkage determines stress levels in teeth with direct restorations, while its impact on adhesion in indirectly restored teeth is insignificant. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Interaction of the Human Contact System with Pathogens-An Update.
Oehmcke-Hecht, Sonja; Köhler, Juliane
2018-01-01
The name human contact system is related to its mode of action, as "contact" with artificial negatively charged surfaces triggers its activation. Today, it is generally believed that the contact system is an inflammatory response mechanism not only against artificial material but also against misfolded proteins and foreign organisms. Upon activation, the contact system is involved in at least two distinct (patho)physiologic processes: i . the trigger of the intrinsic coagulation via factor XI and ii . the cleavage of high molecular weight kininogen with release of bradykinin and antimicrobial peptides (AMPs). Bradykinin is involved in the regulation of inflammatory processes, vascular permeability, and blood pressure. Due to the release of AMPs, the contact system is regarded as a branch of the innate immune defense against microorganisms. There is an increasing list of pathogens that interact with contact factors, in addition to bacteria also fungi and viruses bind and activate the system. In spite of that, pathogens have developed their own mechanisms to activate the contact system, resulting in manipulation of this host immune response. In this up-to-date review, we summarize present research on the interaction of pathogens with the human contact system, focusing particularly on bacterial and viral mechanisms that trigger inflammation via contact system activation.
An improved method for piezoelectric characterization of polymers for energy harvesting applications
NASA Astrophysics Data System (ADS)
Gusarova, E.; Gusarov, B.; Zakharov, D.; Bousquet, M.; Viala, B.; Cugat, O.; Delamare, J.; Gimeno, L.
2013-12-01
This work presents an improved method for measuring the direct piezoelectric voltage and energy of flexible polymers. Well-controlled stress is applied with a four-point bending system and voltage is measured in real open-circuit conditions. The presented method separates the piezoelectric part from the measurement part by introducing a mechanical switch, allowing instantaneous post-deformation discharge measurements. Oscilloscope and contact-less electrostatic voltmeter are compared. Direct piezoelectric measurements under open-circuit conditions have been performed on commercial PVDF (polyvinylidene fluoride) and its copolymers. Significant differences to data sheet values (close-circuit conditions) are reported and commented.
The Development and Performance of After-Hours Primary Care in the Netherlands: A Narrative Review.
Smits, Marleen; Rutten, Martijn; Keizer, Ellen; Wensing, Michel; Westert, Gert; Giesen, Paul
2017-05-16
In many Western countries, hospital emergency departments are overcrowded, leading to the desire to strengthen primary care, particularly after hours. To achieve this goal, an increasing number of Western nations are reorganizing their after-hours primary care systems into large-scale primary care physician (PCP) cooperatives. This article provides an overview of the organization, performance, and development of PCP cooperatives in the Netherlands. The Dutch after-hours primary care system might offer opportunities for other countries facing problems with after-hours care and inappropriate emergency department visits. During the past several years, the number of contacts with Dutch PCP cooperatives has increased to 245 contacts per 1000 citizens per year. Many contacts (45%) are nonurgent, and about half occur as part of a series of primary care contacts. Low accessibility and availability of daytime primary care are related to greater use of after-hours primary care. To prevent unnecessary attendance at the cooperatives, physicians advocate copayment, a stricter triage system, and a larger role for telephone doctors. More than half of the PCP cooperatives in the Netherlands have integrated with hospital emergency departments, forming "emergency care access points." This collaboration has decreased emergency department use by 13% to 22%, and treatment of self-referrals by PCP cooperatives in emergency care access points is safe and cost-effective. Direct access to diagnostic facilities may optimize efficiency even more. Other recent developments include access to electronic health records of daytime primary care practices, task substitution from physicians to nurses, and the launch of a 2-year training program for PCPs to become experts in emergency care.
Chen, Yongqiang; Xie, Quan; Sari, Ahmad; ...
2017-11-21
Wettability of the oil/brine/rock system is an essential petro-physical parameter which governs subsurface multiphase flow behaviour and the distribution of fluids, thus directly affecting oil recovery. Recent studies [1–3] show that manipulation of injected brine composition can enhance oil recovery by shifting wettability from oil-wet to water-wet. However, what factor(s) control system wettability has not been completely elucidated due to incomplete understanding of the geochemical system. To isolate and identify the key factors at play we used in this paper SO 4 2—free solutions to examine the effect of salinity (formation brine/FB, 10 times diluted formation brine/10 dFB, and 100more » times diluted formation brine/100 dFB) on the contact angle of oil droplets at the surface of calcite. We then compared contact angle results with predictions of surface complexation by low salinity water using PHREEQC software. We demonstrate that the conventional dilution approach likely triggers an oil-wet system at low pH, which may explain why the low salinity water EOR-effect is not always observed by injecting low salinity water in carbonated reservoirs. pH plays a fundamental role in the surface chemistry of oil/brine interfaces, and wettability. Our contact angle results show that formation brine triggered a strong water-wet system (35°) at pH 2.55, yet 100 times diluted formation brine led to a strongly oil-wet system (contact angle = 175°) at pH 5.68. Surface complexation modelling correctly predicted the wettability trend with salinity; the bond product sum ([>CaOH 2 +][–COO -] + [>CO 3 -][–NH +] + [>CO 3 -][–COOCa +]) increased with decreasing salinity. Finally, at pH < 6 dilution likely makes the calcite surface oil-wet, particularly for crude oils with high base number. Yet, dilution probably causes water wetness at pH > 7 for crude oils with high acid number.« less
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chen, Yongqiang; Xie, Quan; Sari, Ahmad
Wettability of the oil/brine/rock system is an essential petro-physical parameter which governs subsurface multiphase flow behaviour and the distribution of fluids, thus directly affecting oil recovery. Recent studies [1–3] show that manipulation of injected brine composition can enhance oil recovery by shifting wettability from oil-wet to water-wet. However, what factor(s) control system wettability has not been completely elucidated due to incomplete understanding of the geochemical system. To isolate and identify the key factors at play we used in this paper SO 4 2—free solutions to examine the effect of salinity (formation brine/FB, 10 times diluted formation brine/10 dFB, and 100more » times diluted formation brine/100 dFB) on the contact angle of oil droplets at the surface of calcite. We then compared contact angle results with predictions of surface complexation by low salinity water using PHREEQC software. We demonstrate that the conventional dilution approach likely triggers an oil-wet system at low pH, which may explain why the low salinity water EOR-effect is not always observed by injecting low salinity water in carbonated reservoirs. pH plays a fundamental role in the surface chemistry of oil/brine interfaces, and wettability. Our contact angle results show that formation brine triggered a strong water-wet system (35°) at pH 2.55, yet 100 times diluted formation brine led to a strongly oil-wet system (contact angle = 175°) at pH 5.68. Surface complexation modelling correctly predicted the wettability trend with salinity; the bond product sum ([>CaOH 2 +][–COO -] + [>CO 3 -][–NH +] + [>CO 3 -][–COOCa +]) increased with decreasing salinity. Finally, at pH < 6 dilution likely makes the calcite surface oil-wet, particularly for crude oils with high base number. Yet, dilution probably causes water wetness at pH > 7 for crude oils with high acid number.« less
Contact Dermatitis in Pediatrics.
Pelletier, Janice L; Perez, Caroline; Jacob, Sharon E
2016-08-01
Contact dermatitis is an umbrella term that describes the skin's reaction to contacted noxious or allergenic substances. The two main categories of contact dermatitis are irritant type and allergic type. This review discusses the signs, symptoms, causes, and complications of contact dermatitis. It addresses the testing, treatment, and prevention of contact dermatitis. Proper management of contact dermatitis includes avoidance measures for susceptible children. Implementation of a nickel directive (regulating the use of nickel in jewelry and other products that come into contact with the skin) could further reduce exposure to the most common allergens in the pediatric population. [Pediatr Ann. 2016;45(8):e287-e292.]. Copyright 2016, SLACK Incorporated.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Chandler, Darrell P.; Brown, Jeremy D.; Call, Douglas R.
2001-09-01
We describe the development and application of a novel electromagnetic flow cell and fluidics system for automated immunomagnetic separation of E. coli directly from unprocessed poultry carcass rinse, and the biochemical coupling of automated sample preparation with nucleic acid microarrays without cell growth. Highly porous nickel foam was used as a magnetic flux conductor. Up to 32% recovery efficiency of 'total' E. coli was achieved within the automated system with 6 sec contact times and 15 minute protocol (from sample injection through elution), statistically similar to cell recovery efficiencies in > 1 hour 'batch' captures. The electromagnet flow cell allowedmore » complete recovery of 2.8 mm particles directly from unprocessed poultry carcass rinse whereas the batch system did not. O157:H7 cells were reproducibly isolated directly from unprocessed poultry rinse with 39% recovery efficiency at 103 cells ml-1 inoculum. Direct plating of washed beads showed positive recovery of O 157:H7 directly from carcass rinse at an inoculum of 10 cells ml-1. Recovered beads were used for direct PCR amplification and microarray detection, with a process-level detection limit (automated cell concentration through microarray detection) of < 103 cells ml-1 carcass rinse. The fluidic system and analytical approach described here are generally applicable to most microbial detection problems and applications.« less
Rabbitt, Sarah M.; Carrubba, Erin; Lecza, Bernadette; McWhinney, Emily; Pope, Jennifer; Kazdin, Alan E.
2016-01-01
This study evaluated two Internet-based versions of Parent Management Training (PMT) and the effects of greatly reducing the contact required of a mental health professional on treatment of children referred for conduct problems. We were interested whether reduced contact with a therapist influenced treatment outcome, therapeutic alliance, parent adherence to treatment prescriptions, and parent reactions to and evaluations of the treatment procedures. Sixty children and their caregivers were assigned to receive either Full Contact PMT (with the amount of weekly contact similar to traditional PMT; approximately 50 minutes of direct therapist contact each week) or Reduced Contact PMT (with most information provided through recordings; approximately 10 minutes of therapist contact each week). Children in both groups showed significant and similar reductions in antisocial behaviors specifically, internalizing and externalizing symptoms more generally, and improvements in overall adaptive functioning. Therapeutic alliance also was similar across the two treatment groups. However, parents rated Full Contact treatment as more acceptable than the reduced version. Both treatments were similar in outcomes to in-person treatment as evaluated by a nonrandomized matched sample used as a benchmark in supplementary analyses. Overall, the findings indicate that therapist contact can be reduced while positive treatment outcomes are maintained but that interventions that reduce direct time with a therapist may be viewed less positively by clients. PMID:27453678
Study on electromagnetic plasma propulsion using rotating magnetic field acceleration scheme
NASA Astrophysics Data System (ADS)
Furukawa, T.; Takizawa, K.; Kuwahara, D.; Shinohara, S.
2017-04-01
As one of the electromagnetic plasma acceleration systems, we have proposed a rotating magnetic field (RMF) acceleration scheme to overcome the present problem of direct plasma-electrode interactions, leading to a short lifetime with a poor plasma performance due to contamination. In this scheme, we generate a plasma by a helicon wave excited by a radio frequency (rf) antenna which has no direct-contact with a plasma. Then, the produced plasma is accelerated by the axial Lorentz force fz = jθ × Br (jθ is an azimuthal current induced by RMF, and Br is an external radial magnetic field). Erosion of electrodes and contamination are not expected in this total system since RMF coils and an rf antenna do not have contact with the plasma directly. Here, we have measured the plasma parameters (electron density ne and axial ion velocity vi) to demonstrate this RMF acceleration scheme by the use of AC currents in two sets of opposing coils to generate a RMF. The maximum increasing rate Δvi /vi was ˜28% (maximum vi of ˜3 km/s), while the density increasing rate of Δne/ne is ˜ 70% in the case of a RMF current frequency fRMF of 3 MHz, which showed a better plasma performance than that with fRMF = 5 MHz. Moreover, thrust characteristics such as a specific impulse and a thrust efficiency were discussed, although a target plasma was not optimized.
A method to measure internal contact angle in opaque systems by magnetic resonance imaging.
Zhu, Weiqin; Tian, Ye; Gao, Xuefeng; Jiang, Lei
2013-07-23
Internal contact angle is an important parameter for internal wettability characterization. However, due to the limitation of optical imaging, methods available for contact angle measurement are only suitable for transparent or open systems. For most of the practical situations that require contact angle measurement in opaque or enclosed systems, the traditional methods are not effective. Based upon the requirement, a method suitable for contact angle measurement in nontransparent systems is developed by employing MRI technology. In the Article, the method is demonstrated by measuring internal contact angles in opaque cylindrical tubes. It proves that the method also shows great feasibility in transparent situations and opaque capillary systems. By using the method, contact angle in opaque systems could be measured successfully, which is significant in understanding the wetting behaviors in nontransparent systems and calculating interfacial parameters in enclosed systems.
Zhang, Han; Wainwright, Marcy; Byrne, John H.; Cleary, Leonard J.
2003-01-01
Present models of long-term sensitization in Aplysia californica indicate that the enhanced behavioral response is due, at least in part, to outgrowth of sensory neurons mediating defensive withdrawal reflexes. Presumably, this outgrowth strengthens pre-existing connections by formation of newsynapses with follower neurons. However, the relationship between the number of sensorimotor contacts and the physiological strength of the connection has never been examined in intact ganglia. As a first step in addressing this issue, we used confocal microscopy to examine sites of contact between sensory and motor neurons in naive animals. Our results revealed relatively fewcontacts between physiologically connected cells. In addition, the number of contact sites was proportional to the amplitude of the EPSP elicited in the follower motor neuron by direct stimulation of the sensory neuron. This is the first time such a correlation has been observed in the central nervous system. Serotonin is the neurotransmitter most closely examined for its role in modulating synaptic strength at the sensorimotor synapse. However, the structural relationship of serotonergic processes and sensorimotor synapses has never been examined. Surprisingly, serotonergic processes usually made contact with sensory and motor neurons at sites located relatively distant from the sensorimotor synapse. This result implies that heterosynaptic regulation is due to nondirected release of serotonin into the neuropil. PMID:14557611
Bioinspired Flexible and Highly Responsive Dual-Mode Strain/Magnetism Composite Sensor.
Huang, Pei; Li, Yuan-Qing; Yu, Xiao-Guang; Zhu, Wei-Bin; Nie, Shu-Yan; Zhang, Hao; Liu, Jin-Rui; Hu, Ning; Fu, Shao-Yun
2018-04-04
The mimicry of human skin to detect both oncoming and physical-contacting object is of great importance in the fields of manufacturing, artificial robots and vehicles, etc. Herein, a novel bioinspired flexible and highly responsive dual-mode strain/magnetism composite sensor, which works via both contact and contactless modes, is first fabricated by incorporating Fe 3 O 4 /silicone system into a carbon fiber aerogel (CFA). The distance dependence of magnetic field endorses the CFA/Fe 3 O 4 /silicone composite possible for spatial sensing due to the introduction of Fe 3 O 4 magnetic nanoparticles. As a result, the as-prepared flexible sensor exhibits precise and real-time response not only to direct-contact compression as usual but also to contactless magnetic field in a wide frequency range from 0.1 to 10 Hz, achieving the maximum variance of 68% and 86% in relative electrical resistance, respectively. The contact and contactless sensing modes of the strain/magnetism sensor are clearly demonstrated by recording the speeds of bicycle riding and walking, respectively. Interestingly, this dual-mode composite sensor exhibits the capacity of identifying the contact and contactless state, which is the first report for flexible sensors. The current protocol is eco-friendly, facile, and thought-provoking for the fabrication of multifunctional sensors.
Hydrogen peroxide mechanosynthesis in siloxane-hydrogel contact lenses.
Tavazzi, Silvia; Ferraro, Lorenzo; Cozza, Federica; Pastori, Valentina; Lecchi, Marzia; Farris, Stefano; Borghesi, Alessandro
2014-11-26
Drug-loaded contact lenses are emerging as the preferred treatment method for several ocular diseases, and efforts are being directed to promote extended and controlled delivery. One strategy is based on delivery induced by environmental triggers. One of these triggers can be hydrogen peroxide, since many platforms based on drug-loaded nanoparticles were demonstrated to be hydrogen-peroxide responsive. This is particularly interesting when hydrogen peroxide is the result of a specific pathophysiological condition. Otherwise, an alternative route to induce drug delivery is here proposed, namely the mechano-synthesis. The present work represents the proof-of-concept of the mechanosynthesis of hydrogen peroxide in siloxane-hydrogel contact lenses as a consequence of the cleavage of siloxane bonds at the interface between the polymer and water in aqueous phase. Their spongy morphology makes contact lenses promising systems for mechanical-to-chemical energy conversion, since the amount of hydrogen peroxide is expected to scale with the interfacial area between the polymer and water. The eyelid pressure during wear is sufficient to induce the hydrogen peroxide synthesis with concentrations which are biocompatible and suitable to trigger the drug release through hydrogen-peroxide-responsive platforms. For possible delivery on demand, the integration of piezoelectric polymers in the siloxane-hydrogel contact lenses could be designed, whose mechanical deformation could be induced by an applied wireless-controlled voltage.
Radhakrishnan, S; Chopra, Ajay; Mitra, Debdeep; Gnanasekaran, R; Kanagaraj, R
2017-07-01
Ground crew of the Air Force routinely handle aviation turbine fuel (ATF) and lubricants and a need was felt to study the adverse effects of these substances on their skin so that remedial measures could be taken to prevent these adverse effects. A multi-centric, cross-sectional, observational study was performed at three Air Force flying stations. 109 ground crew members of the Indian Air Force (IAF) who were in direct contact with ATF and lubricants were screened for dermatological manifestations on exposed areas. History of atopy was elicited, systemic and dermatological examination done and occlusive patch testing carried out where indicated. Fungal infections were excluded by a potassium hydroxide mount. 20 out of the 109 personnel (18.34%) were symptomatic in the form of mild irritant contact dermatitis. There was no case of allergic contact dermatitis. Only two cases showed an irritant reaction on patch testing. 65% of the symptomatic personnel were atopic. There was no predisposing trade or age group for adverse effects to ATF. This study revealed that contact with ATF is associated with only mild irritant contact dermatitis in exposed ground crew members of the IAF and atopy was a predisposing factor for susceptibility to the dermatitis.
Communication strategies and timeliness of response to life critical telemetry alarms.
Bonzheim, Kimberly A; Gebara, Rani I; O'Hare, Bridget M; Ellis, R Darin; Brand, Monique A; Balar, Salil D; Stockman, Rita; Sciberras, Annette M; Haines, David E
2011-05-01
A centralized electrocardiogram telemetry monitoring system (TMS) facilitates early identification of critical arrhythmias and acute medical decompensation. Timely intervention can only be performed if abnormalities are communicated rapidly to the direct caregiver. The study objectives were to measure effectiveness of bi-directional voice communication badges versus one-way alphanumeric pagers for telemetry alarm response and communication loop closure. A sequential observational pilot study of nursing response to TMS alarms compared communication technologies on four nursing units in a 1,061 bed tertiary care hospital with 264 TMS channels of telemetry over a 2-year period. Subsequently, the communication technologies were compared in a randomized fashion on a 68-bed progressive cardiac care unit. Caregivers were blinded to the protocol. All alarm responses were recorded during two periods using either pagers or voice communication devices. Alarm response time and closure of the communication loop were analyzed in a blinded fashion. The direct communication functionality of the badge significantly shortened the time to first contact, time to completion, and rate of closure of the communication loop in both the pilot and study phases. Median time to first contact with the communication badge was 0.5 min, compared to 1.6 min with pager communication (p < 0.0003). Communication loop closure was achieved in 100% of clinical alarms using the badge versus 19% with the pager (p < 0.0001). Communication badge technology reduced alarm time to first contact and completion as well as facilitated communication loop closures. Immediate two-way communication significantly impacted practice, alarm management, and resulted in faster bedside care.
Smolders, Andrew; Rolls, Robert J; Ryder, Darren; Watkinson, Andrew; Mackenzie, Mark
2015-06-01
The provision of safe drinking water is a global issue, and animal production is recognized as a significant potential origin of human infectious pathogenic microorganisms within source water catchments. On-farm management can be used to mitigate livestock-derived microbial pollution in source water catchments to reduce the risk of contamination to potable water supplies. We applied a modified Before-After Control Impact (BACI) design to test if restricting the access of livestock to direct contact with streams prevented longitudinal increases in the concentrations of faecal indicator bacteria and suspended solids. Significant longitudinal increases in pollutant concentrations were detected between upstream and downstream reaches of the control crossing, whereas such increases were not detected at the treatment crossing. Therefore, while the crossing upgrade was effective in preventing cattle-derived point source pollution by between 112 and 158%, diffuse source pollution to water supplies from livestock is not ameliorated by this intervention alone. Our findings indicate that stream crossings that prevent direct contact between livestock and waterways provide a simple method for reducing pollutant loads in source water catchments, which ultimately minimises the likelihood of pathogenic microorganisms passing through source water catchments and the drinking water supply system. The efficacy of the catchment as a primary barrier to pathogenic risks to drinking water supplies would be improved with the integration of management interventions that minimise direct contact between livestock and waterways, combined with the mitigation of diffuse sources of livestock-derived faecal matter from farmland runoff to the aquatic environment. Copyright © 2015 Elsevier Ltd. All rights reserved.
Numerical Analysis of the Influence of Low Frequency Vibration on Bubble Growth
Han, D.; Kedzierski, Mark A.
2017-01-01
Numerical simulation of bubble growth during pool boiling under the influence of low frequency vibration was performed to understand the influence of common vibrations such as those induced by wind, highway transportation, and nearby mechanical devices on the performance of thermal systems that rely on boiling. The simulations were done for saturated R123 boiling at 277.6 K with a 15 K wall superheat. The numerical volume-of-fluid method (fixed grid) was used to define the liquid-vapor interface. The basic bubble growth characteristics including the bubble departure diameter and the bubble departure time were determined as a function of the bubble contact angle (20°–80°), the vibration displacement (10 µm–50 µm), the vibration frequency (5 Hz–25 Hz), and the initial vibration direction (positive or negative). The bubble parameters were shown to be strongly dependent on the bubble contact angle at the surface. For example, both the bubble departure diameter and the bubble departure time increased with the contact angle. At the same vibration frequency and the initial vibration direction, the bubble departure diameter and the bubble departure time both decreased with increasing vibration displacement. In addition, the vibration frequency had a greater effect on the bubble growth characteristics than did the vibration displacement. The vibration frequency effect was strongly influenced by the initial vibration direction. The pressure contour, the volume fraction of vapor phase, the temperature profile, and the velocity vector were investigated to understand these dynamic bubble behaviors. The limitation of the computational fluid dynamics approach was also described. PMID:28747812
Code of Federal Regulations, 2010 CFR
2010-04-01
... representative; direct contact with taxpayer; delivery of a check drawn on the United States Treasury to... taxpayer; delivery of a check drawn on the United States Treasury to recognized representative. (a) General... disciplinary proceedings under Circular No. 230, 31 CFR part 10. (c) Delivery of a check drawn on the United...
ERIC Educational Resources Information Center
Wicke, Rainer E.
This guide is a summary of ideas for enhancing the teaching of German through direct contact with Germany or German people without traveling abroad. The following ideas are highlighted: (1) correspondence (pen pals) with students in Germany; (2) audiotape recordings as an alternative to letter writing; (3) the exchange of videotape recordings with…
Aternating current photovoltaic building block
Bower, Ward Issac; Thomas, Michael G.; Ruby, Douglas S.
2004-06-15
A modular apparatus for and method of alternating current photovoltaic power generation comprising via a photovoltaic module, generating power in the form of direct current; and converting direct current to alternating current and exporting power via one or more power conversion and transfer units attached to the module, each unit comprising a unitary housing extending a length or width of the module, which housing comprises: contact means for receiving direct current from the module; one or more direct current-to-alternating current inverters; an alternating current bus; and contact means for receiving alternating current from the one or more inverters.
Critical short-time dynamics in a system with interacting static and diffusive populations
NASA Astrophysics Data System (ADS)
Argolo, C.; Quintino, Yan; Gleria, Iram; Lyra, M. L.
2012-01-01
We study the critical short-time dynamical behavior of a one-dimensional model where diffusive individuals can infect a static population upon contact. The model presents an absorbing phase transition from an active to an inactive state. Previous calculations of the critical exponents based on quasistationary quantities have indicated an unusual crossover from the directed percolation to the diffusive contact process universality classes. Here we show that the critical exponents governing the slow short-time dynamic evolution of several relevant quantities, including the order parameter, its relative fluctuations, and correlation function, reinforce the lack of universality in this model. Accurate estimates show that the critical exponents are distinct in the regimes of low and high recovery rates.
The Cost of Being Watched: Stroop Interference Increases under Concomitant Eye Contact
ERIC Educational Resources Information Center
Conty, Laurence; Gimmig, David; Belletier, Clement; George, Nathalie; Huguet, Pascal
2010-01-01
Current models in social neuroscience advance that eye contact may automatically recruit cognitive resources. Here, we directly tested this hypothesis by evaluating the distracting strength of eye contact on concurrent visual processing in the well-known Stroop's paradigm. As expected, participants showed stronger Stroop interference under…
46 CFR Appendix C to Subpart C to... - Medical Surveillance Guidelines for Benzene
Code of Federal Regulations, 2010 CFR
2010-10-01
... produce primary irritation due to repeated or prolonged contact with the skin. High concentrations are... Direct skin contact with benzene may cause erythema. Repeated or prolonged contact may result in drying, scaling dermatitis or development of secondary skin infections. In addition, benzene is absorbed through...
Evaluation of Salmonella biofilm cell transfer from contact surfaces to beef products
USDA-ARS?s Scientific Manuscript database
Introduction: Meat contamination by Salmonella enterica is a serious food safety concern. One common transmission route that leads to cross contamination in meat plants is bacteria transfer from biofilms on contact surfaces to meat products via direct contact. Many factors could affect biofilm tra...
Microwave-induced direct spin-flip transitions in mesoscopic Pd/Co heterojunctions
NASA Astrophysics Data System (ADS)
Pietsch, Torsten; Egle, Stefan; Keller, Martin; Fridtjof-Pernau, Hans; Strigl, Florian; Scheer, Elke
2016-09-01
We experimentally investigate the effect of resonant microwave absorption on the magneto-conductance of tunable Co/Pd point contacts. At the interface a non-equilibrium spin accumulation is created via microwave absorption and can be probed via point contact spectroscopy. We interpret the results as a signature of direct spin-flip excitations in Zeeman-split spin-subbands within the Pd normal metal part of the junction. The inverse effect, which is associated with the emission of a microwave photon in a ferromagnet/normal metal point contact, can also be detected via its unique signature in transport spectroscopy.
Fischer, Kenneth J; Johnson, Joshua E; Waller, Alexander J; McIff, Terence E; Toby, E Bruce; Bilgen, Mehmet
2011-10-01
The objective of this study was to validate the MRI-based joint contact modeling methodology in the radiocarpal joints by comparison of model results with invasive specimen-specific radiocarpal contact measurements from four cadaver experiments. We used a single validation criterion for multiple outcome measures to characterize the utility and overall validity of the modeling approach. For each experiment, a Pressurex film and a Tekscan sensor were sequentially placed into the radiocarpal joints during simulated grasp. Computer models were constructed based on MRI visualization of the cadaver specimens without load. Images were also acquired during the loaded configuration used with the direct experimental measurements. Geometric surface models of the radius, scaphoid and lunate (including cartilage) were constructed from the images acquired without the load. The carpal bone motions from the unloaded state to the loaded state were determined using a series of 3D image registrations. Cartilage thickness was assumed uniform at 1.0 mm with an effective compressive modulus of 4 MPa. Validation was based on experimental versus model contact area, contact force, average contact pressure and peak contact pressure for the radioscaphoid and radiolunate articulations. Contact area was also measured directly from images acquired under load and compared to the experimental and model data. Qualitatively, there was good correspondence between the MRI-based model data and experimental data, with consistent relative size, shape and location of radioscaphoid and radiolunate contact regions. Quantitative data from the model generally compared well with the experimental data for all specimens. Contact area from the MRI-based model was very similar to the contact area measured directly from the images. For all outcome measures except average and peak pressures, at least two specimen models met the validation criteria with respect to experimental measurements for both articulations. Only the model for one specimen met the validation criteria for average and peak pressure of both articulations; however the experimental measures for peak pressure also exhibited high variability. MRI-based modeling can reliably be used for evaluating the contact area and contact force with similar confidence as in currently available experimental techniques. Average contact pressure, and peak contact pressure were more variable from all measurement techniques, and these measures from MRI-based modeling should be used with some caution.
Direct skin-to-skin vs. indirect touch modulates neural responses to stroking vs. tapping
Kress, Inge U; Minati, Ludovico; Ferraro, Stefania; Critchley, Hugo D
2011-01-01
It remains unclear whether direct inter-personal contact is processed differently from similar soft touch applied through inanimate objects. We performed a functional MRI (fMRI) experiment in healthy volunteers, whereby activity during gentle stroking or tapping was compared between stimuli delivered using the experimenter’s hand or a velvet stick. Stroking with a hand elicited larger responses than the other three conditions in the contralateral primary and secondary somatosensory areas and posterior insula. The observed effects likely originate from a combination of perceptual differences and cognitive and emotional correlates of contact with another person. This empirical observation indicates that to ensure ecological validity studies of affective touch processing should be performed with stimuli delivered with direct inter-personal contact rather than inanimate objects. PMID:21817928
A Framework for Developing Mobile Location Based Applications
2006-10-01
B into the application running on her mobile device. The mobile application contacts the appropriate service provided by T- mobile which calculates...the optimal route between points A and B. The mobile application then displays driving directions to point B in a fashion similar to one found in car...navigation systems. The mobile application requires a Bluetooth GPS receiver to be connected to the mobile device to determine its current position
Communication among Oral Bacteria
Kolenbrander, Paul E.; Andersen, Roxanna N.; Blehert, David S.; Egland, Paul G.; Foster, Jamie S.; Palmer, Robert J.
2002-01-01
Human oral bacteria interact with their environment by attaching to surfaces and establishing mixed-species communities. As each bacterial cell attaches, it forms a new surface to which other cells can adhere. Adherence and community development are spatiotemporal; such order requires communication. The discovery of soluble signals, such as autoinducer-2, that may be exchanged within multispecies communities to convey information between organisms has emerged as a new research direction. Direct-contact signals, such as adhesins and receptors, that elicit changes in gene expression after cell-cell contact and biofilm growth are also an active research area. Considering that the majority of oral bacteria are organized in dense three-dimensional biofilms on teeth, confocal microscopy and fluorescently labeled probes provide valuable approaches for investigating the architecture of these organized communities in situ. Oral biofilms are readily accessible to microbiologists and are excellent model systems for studies of microbial communication. One attractive model system is a saliva-coated flowcell with oral bacterial biofilms growing on saliva as the sole nutrient source; an intergeneric mutualism is discussed. Several oral bacterial species are amenable to genetic manipulation for molecular characterization of communication both among bacteria and between bacteria and the host. A successful search for genes critical for mixed-species community organization will be accomplished only when it is conducted with mixed-species communities. PMID:12209001
Rapid quantitative chemical mapping of surfaces with sub-2 nm resolution
NASA Astrophysics Data System (ADS)
Lai, Chia-Yun; Perri, Saverio; Santos, Sergio; Garcia, Ricardo; Chiesa, Matteo
2016-05-01
We present a theory that exploits four observables in bimodal atomic force microscopy to produce maps of the Hamaker constant H. The quantitative H maps may be employed by the broader community to directly interpret the high resolution of standard bimodal AFM images as chemical maps while simultaneously quantifying chemistry in the non-contact regime. We further provide a simple methodology to optimize a range of operational parameters for which H is in the closest agreement with the Lifshitz theory in order to (1) simplify data acquisition and (2) generalize the methodology to any set of cantilever-sample systems.We present a theory that exploits four observables in bimodal atomic force microscopy to produce maps of the Hamaker constant H. The quantitative H maps may be employed by the broader community to directly interpret the high resolution of standard bimodal AFM images as chemical maps while simultaneously quantifying chemistry in the non-contact regime. We further provide a simple methodology to optimize a range of operational parameters for which H is in the closest agreement with the Lifshitz theory in order to (1) simplify data acquisition and (2) generalize the methodology to any set of cantilever-sample systems. Electronic supplementary information (ESI) available. See DOI: 10.1039/c6nr00496b
Contact guidance is cell cycle-dependent.
Pourfarhangi, Kamyar Esmaeili; De La Hoz, Edgar Cardenas; Cohen, Andrew R; Gligorijevic, Bojana
2018-09-01
Cancer cell migration is essential for metastasis, during which cancer cells move through the tumor and reach the blood vessels. In vivo , cancer cells are exposed to contact guidance and chemotactic cues. Depending on the strength of such cues, cells will migrate in a random or directed manner. While similar cues may also stimulate cell proliferation, it is not clear whether cell cycle progression affects migration of cancer cells and whether this effect is different in random versus directed migration. In this study, we tested the effect of cell cycle progression on contact guided migration in 2D and 3D environments, in the breast carcinoma cell line, FUCCI-MDA-MB-231. The results were quantified from live cell microscopy images using the open source lineage editing and validation image analysis tools (LEVER). In 2D, cells were placed inside 10 μ m-wide microchannels to stimulate contact guidance, with or without an additional chemotactic gradient of the soluble epidermal growth factor. In 3D, contact guidance was modeled by aligned collagen fibers. In both 2D and 3D, contact guidance was cell cycle-dependent, while the addition of the chemo-attractant gradient in 2D increased cell velocity and persistence in directionally migrating cells, regardless of their cell cycle phases. In both 2D and 3D contact guidance, cells in the G1 phase of the cell cycle outperformed cells in the S/G2 phase in terms of migration persistence and instantaneous velocity. These data suggest that in the presence of contact guidance cues in vivo , breast carcinoma cells in the G1 phase of the cell cycle may be more efficient in reaching the neighboring vasculature.
Local Synthesis and Tooth Contact Analysis of Face-Milled Spiral Bevel Gears
NASA Technical Reports Server (NTRS)
Litvin, Faydor L.; Zhang, Yi
1991-01-01
Computerized simulation of meshing and bearing contact for spiral bevel gears and hypoid gears is a significant achievement that could substantially improve the technology and the quality of the gears. An approach to the synthesis of face-milled spiral bevel gears and their tooth contact analysis is presented. The proposed approach is based on the following ideas: application of the principle of local synthesis that provides optimal conditions of meshing and contact at the mean contact point, M, and in the neighborhood of M; and application of relations between principle directions and curvatures for surfaces being in line contact or in point contact. The developed local synthesis of gears provides the following: (1) the required gear ratio at M; (2) a localized bearing contact with the desired direction of the tangent to the contact path on gear tooth surface and the desired length of the major axis of contact ellipse at M; (3) a predesigned parabolic function of a controlled level for transmission errors which enables absorption of linear functions of transmission errors caused by misalignment and reduces the level of vibrations. The proposed approach does not require either the tilt of the head-cutter for the process of generation or modified roll for the pinion generation. Improved conditions of meshing and contact of the gears can be achieved without the above mentioned parameters. A computer program for determination of basic machine-tool settings and tooth contact analysis for the designed gears is presented. The approach is illustrated with a numerical example.
Tsukamoto, Yoshihiko; Omi, Naoko
2016-01-01
To date, 12 macaque bipolar cell types have been described. This list includes all morphology types first outlined by Polyak (1941) using the Golgi method in the primate retina and subsequently identified by other researchers using electron microscopy (EM) combined with the Golgi method, serial section transmission EM (SSTEM), and immunohistochemical imaging. We used SSTEM for the rod-dense perifoveal area of macaque retina, reconfirmed ON (cone) bipolar cells to be classified as invaginating midget bipolar (IMB), diffuse bipolar (DB)4, DB5, DB6, giant bipolar (GB), and blue bipolar (BB) types, and clarified their type-specific connectivity. DB4 cells made reciprocal synapses with a kind of ON-OFF lateral amacrine cell, similar to OFF DB2 cells. GB cells contacted rods and cones, similar to OFF DB3b cells. Retinal circuits formed by GB and DB3b cells are thought to substantiate the psychophysical finding of fast rod signals in mesopic vision. DB6 cell output synapses were directed to ON midget ganglion (MG) cells at 70% of ribbon contacts, similar to OFF DB1 cells that directed 60% of ribbon contacts to OFF MG cells. IMB cells contacted medium- or long-wavelength sensitive (M/L-) cones but not short-wavelength sensitive (S-) cones, while BB cells contacted S-cones but not M/L-cones. However, IMB and BB dendrites had similar morphological architectures, and a BB cell contacting a single S-cone resembled an IMB cell. Thus, both IMB and BB may be the ON bipolar counterparts of the OFF flat midget bipolar (FMB) type, likewise DB4 of DB2, DB5 of DB3a, DB6 of DB1, and GB of DB3b OFF bipolar type. The ON DB plus GB, and OFF DB cells predominantly contacted M/L-cones and their outputs were directed mainly to parasol ganglion (PG) cells but also moderately to MG cells. BB cells directed S-cone-driven outputs almost exclusively to small bistratified ganglion (SBG) cells. Some FMB cells predominantly contacted S-cones and their outputs were directed to OFF MG cells. Thus, two-step synaptic connections largely narrowed down the S-cone component to SBG and some OFF MG cells. The other OFF MG cells, ON MG cells, and ON and OFF PG cells constructed M/L-cone dominant pathways. PMID:27833534
Cellular Scale Anisotropic Topography Guides Schwann Cell Motility
Mitchel, Jennifer A.; Hoffman-Kim, Diane
2011-01-01
Directed migration of Schwann cells (SC) is critical for development and repair of the peripheral nervous system. Understanding aspects of motility specific to SC, along with SC response to engineered biomaterials, may inform strategies to enhance nerve regeneration. Rat SC were cultured on laminin-coated microgrooved poly(dimethyl siloxane) platforms that were flat or presented repeating cellular scale anisotropic topographical cues, 30 or 60 µm in width, and observed with timelapse microscopy. SC motion was directed parallel to the long axis of the topography on both the groove floor and the plateau, with accompanying differences in velocity and directional persistence in comparison to SC motion on flat substrates. In addition, feature dimension affected SC morphology, alignment, and directional persistence. Plateaus and groove floors presented distinct cues which promoted differential motility and variable interaction with the topographical features. SC on the plateau surfaces tended to have persistent interactions with the edge topography, while SC on the groove floors tended to have infrequent contact with the corners and walls. Our observations suggest the capacity of SC to be guided without continuous contact with a topographical cue. SC exhibited a range of distinct motile morphologies, characterized by their symmetry and number of extensions. Across all conditions, SC with a single extension traveled significantly faster than cells with more or no extensions. We conclude that SC motility is complex, where persistent motion requires cellular asymmetry, and that anisotropic topography with cellular scale features can direct SC motility. PMID:21949703
Design and test of a system for tracking referrals.
Bauman, K E; Coulter, M
1976-01-01
Many health and welfare programs are based on a model in which services needed by consumers are identified by one agency with referral to others for provision of services. The referring agency often does not know whether the services recommended are received, yet it is assumed that receipt of those services by their clients is essential to achievement of program goals. A procedure was devised for tracking families evaluated by North Carolina's State-supported developmental evaluation centers (DECs), agencies that reflect this model. The multidisciplinary evaluation teams of these centers serve children and their families of all income levels. The developmental evaluation family tracking system is a method for determining if recommended services are received, the reasons why they are not, and whether the family desires additional help from the center or othersources. The system was piloted in the Greensboro DEC with a selected group of 67 families. Parents were contacted, mostly by telephone, at 6 months and 18 months following evaluation. Tracking forms were completed for 61 families. Professional staff spent only 2.7% of their working hours during a 3-month period on direct tracking activities and other tasks in behalf of the consumers contacted. The cost was $7.15 per case for immediate tracking and $14.49 if additional activities generated by the tracking contact were included. The system, which provides the information necessary for achieving program goals, was implemented for all 11 DECs in North Carolina in 1976.
Specificity in Sociality: Mice and Prairie Voles Exhibit Different Patterns of Peer Affiliation
Beery, Annaliese K.; Christensen, Jennifer D; Lee, Nicole S.; Blandino, Katrina L.
2018-01-01
Social behavior is often described as a unified concept, but highly social (group-living) species exhibit distinct social structures and may make different social decisions. Prairie voles (Microtus ochrogaster) are socially monogamous rodents that often reside in extended family groups, and exhibit robust preferences for familiar social partners (same- and opposite-sex) during extended choice tests, although short-term preferences are not known. Mice (Mus musculus) are gregarious and colonial, but in brief laboratory tests of social preference they typically prefer social novelty. This preference for novel vs. familiar peers may represent a species-specific difference in social decision-making between mice and prairie voles. However, the tests used to measure preferences in each species differ markedly in duration and degree of contact, such that the behaviors cannot be directly compared. We assessed whether social preferences for novelty or familiarity differed between mice and prairie voles of both sexes when assessed with matching protocols: the sociability/social preference test (SPT) typically used in mice (short, no direct contact), and the partner preference test (PPT) used in voles (long, direct contact). A subset of voles also underwent a PPT using barriers (long, no direct contact). In the short SPT, behavior did not differ between species. In the longer test, pronounced partner preferences emerged in prairie voles, but mice exhibited no social preferences and rarely huddled. No sex differences were evident in either test. Direct physical contact was required for partner preferences in huddling time in voles, but preference for the partner chamber was evident with or without contact. Both prairie voles and mice are social, but they exhibit important differences in the specificity and extent of their social behavior. While mice are often used to study social approach and other behaviors, voles are a more suitable species for the study of selective social relationships. Consideration of these differences will be important for studies examining the neural mechanisms supporting different kinds of peer social behavior. PMID:29615879
Aniołczyk, Halina
2006-01-01
Exposure to electromagnetic fields (EMF) occurs when man is exposed to the effect of electric, magnetic and electromagnetic fields and contact currents different from those resulting from physiological processes in the organism or other natural phenomena. In Poland, the system of protection against EMF has been functioning for over 35 years. In 2001, when the Minister of Labor and Social Policy issued the regulation introducing the maximum admissible intensities (MAI) for electromagnetic fields and radiation within the range of 0 Hz-300 GHz, the system was directed mainly towards evaluation of exposure to EMF occurring in the occupational environment. The system is linked via MAI values with human protection in the natural environment. In this paper, the background, principles and the range of the national system of protection against EMF and its monitoring are presented. The project of implementation of EU directives, following Poland's accession to the European Union is also discussed.
NASA Astrophysics Data System (ADS)
Burger, D. R.
1983-11-01
Progress of a photovoltaic (PV) device from a research concept to a competitive power-generation source requires an increasing concern with current collection. The initial metallization focus is usually on contact resistance, since a good ohmic contact is desirable for accurate device characterization measurements. As the device grows in size, sheet resistance losses become important and a metal grid is usually added to reduce the effective sheet resistance. Later, as size and conversion efficiency continue to increase, grid-line resistance and cell shadowing must be considered simultaneously, because grid-line resistance is inversely related to total grid-line area and cell shadowing is directly related. A PV cell grid design must consider the five power-loss phenomena mentioned above: sheet resistance, contact resistance, grid resistance, bus-bar resistance and cell shadowing. Although cost, reliability and usage are important factors in deciding upon the best metallization system, this paper will focus only upon grid-line design and substrate material problems for flat-plate solar arrays.
NASA Astrophysics Data System (ADS)
Bechet, P.; Mitran, R.; Munteanu, M.
2013-08-01
Non-contact methods for the assessment of vital signs are of great interest for specialists due to the benefits obtained in both medical and special applications, such as those for surveillance, monitoring, and search and rescue. This paper investigates the possibility of implementing a digital processing algorithm based on the MUSIC (Multiple Signal Classification) parametric spectral estimation in order to reduce the observation time needed to accurately measure the heart rate. It demonstrates that, by proper dimensioning the signal subspace, the MUSIC algorithm can be optimized in order to accurately assess the heart rate during an 8-28 s time interval. The validation of the processing algorithm performance was achieved by minimizing the mean error of the heart rate after performing simultaneous comparative measurements on several subjects. In order to calculate the error the reference value of heart rate was measured using a classic measurement system through direct contact.
Junction-side illuminated silicon detector arrays
Iwanczyk, Jan S.; Patt, Bradley E.; Tull, Carolyn
2004-03-30
A junction-side illuminated detector array of pixelated detectors is constructed on a silicon wafer. A junction contact on the front-side may cover the whole detector array, and may be used as an entrance window for light, x-ray, gamma ray and/or other particles. The back-side has an array of individual ohmic contact pixels. Each of the ohmic contact pixels on the back-side may be surrounded by a grid or a ring of junction separation implants. Effective pixel size may be changed by separately biasing different sections of the grid. A scintillator may be coupled directly to the entrance window while readout electronics may be coupled directly to the ohmic contact pixels. The detector array may be used as a radiation hardened detector for high-energy physics research or as avalanche imaging arrays.
Conjugate gradient based projection - A new explicit methodology for frictional contact
NASA Technical Reports Server (NTRS)
Tamma, Kumar K.; Li, Maocheng; Sha, Desong
1993-01-01
With special attention towards the applicability to parallel computation or vectorization, a new and effective explicit approach for linear complementary formulations involving a conjugate gradient based projection methodology is proposed in this study for contact problems with Coulomb friction. The overall objectives are focussed towards providing an explicit methodology of computation for the complete contact problem with friction. In this regard, the primary idea for solving the linear complementary formulations stems from an established search direction which is projected to a feasible region determined by the non-negative constraint condition; this direction is then applied to the Fletcher-Reeves conjugate gradient method resulting in a powerful explicit methodology which possesses high accuracy, excellent convergence characteristics, fast computational speed and is relatively simple to implement for contact problems involving Coulomb friction.
NASA Astrophysics Data System (ADS)
Dorin, Bryce; Parkinson, Patrick; Scully, Patricia
2018-04-01
The development of cost-effective electrical packaging for randomly distributed micro/nano-scale devices is a widely recognized challenge for fabrication technologies. Three-dimensional direct laser writing (DLW) has been proposed as a solution to this challenge, and has enabled the creation of rapid and low resistance graphitic wires within commercial polyimide substrates. In this work, we utilize the DLW technique to electrically contact three fully encapsulated and randomly positioned light-emitting diodes (LEDs) in a one-step process. The resolution of the contacts is in the order of 20 μ m, with an average circuit resistance of 29 ± 18 kΩ per LED contacted. The speed and simplicity of this technique is promising to meet the needs of future microelectronics and device packaging.
Better Ohmic Contacts For InP Semiconductor Devices
NASA Technical Reports Server (NTRS)
Weizer, Victor G.; Fatemi, Navid S.
1995-01-01
Four design modifications enable fabrication of improved ohmic contacts on InP-based semiconductor devices. First modification consists of insertion of layer of gold phosphide between n-doped InP and metal or other overlayer of contact material. Second, includes first modification plus use of particular metal overlayer to achieve very low contact resistivities. Third, also involves deposition of Au(2)P(3) interlayer; in addition, refractory metal (W or Ta) deposited to form contact overlayer. In fourth, contact layer of Auln alloy deposited directly on InP. Improved contacts exhibit low electrical resistances and fabricated without exposing devices to destructive predeposition or postdeposition treatments.
The development of a solid-state hydrogen sensor for rocket engine leakage detection
NASA Technical Reports Server (NTRS)
Liu, Chung-Chiun
1994-01-01
Hydrogen propellant leakage poses significant operational problems in the rocket propulsion industry as well as for space exploratory applications. Vigorous efforts have been devoted to minimizing hydrogen leakage in assembly, test, and launch operations related to hydrogen propellant. The objective has been to reduce the operational cost of assembling and maintaining hydrogen delivery systems. Specifically, efforts have been made to develop a hydrogen leak detection system for point-contact measurement. Under the auspices of Lewis Research Center, the Electronics Design Center at Case Western Reserve University, Cleveland, Ohio, has undertaken the development of a point-contact hydrogen gas sensor with potential applications to the hydrogen propellant industry. We envision a sensor array consisting of numbers of discrete hydrogen sensors that can be located in potential leak sites. Silicon-based microfabrication and micromachining techniques are used in the fabrication of these sensor prototypes. Evaluations of the sensor are carried out in-house at Case Western Reserve University as well as at Lewis Research Center and GenCorp Aerojet, Sacramento, California. The hydrogen gas sensor is not only applicable in a hydrogen propulsion system, but also usable in many other civilian and industrial settings. This includes vehicles or facility use, or in the production of hydrogen gas. Dual space and commercial uses of these point-contacted hydrogen sensors are feasible and will directly meet the needs and objectives of NASA as well as various industrial segments.
Interference Effects in a Tunable Quantum Point Contact Integrated with an Electronic Cavity
NASA Astrophysics Data System (ADS)
Yan, Chengyu; Kumar, Sanjeev; Pepper, Michael; See, Patrick; Farrer, Ian; Ritchie, David; Griffiths, Jonathan; Jones, Geraint
2017-08-01
We show experimentally how quantum interference can be produced using an integrated quantum system comprising an arch-shaped short quantum wire (or quantum point contact, QPC) of 1D electrons and a reflector forming an electronic cavity. On tuning the coupling between the QPC and the electronic cavity, fine oscillations are observed when the arch QPC is operated in the quasi-1D regime. These oscillations correspond to interference between the 1D states and a state which is similar to the Fabry-Perot state and suppressed by a small transverse magnetic field of ±60 mT . Tuning the reflector, we find a peak in resistance which follows the behavior expected for a Fano resonance. We suggest that this is an interesting example of a Fano resonance in an open system which corresponds to interference at or near the Ohmic contacts due to a directly propagating, reflected discrete path and the continuum states of the cavity corresponding to multiple scattering. Remarkably, the Fano factor shows an oscillatory behavior taking peaks for each fine oscillation, thus, confirming coupling between the discrete and continuum states. The results indicate that such a simple quantum device can be used as building blocks to create more complex integrated quantum circuits for possible applications ranging from quantum-information processing to realizing the fundamentals of complex quantum systems.
The development of a solid-state hydrogen sensor for rocket engine leakage detection
NASA Astrophysics Data System (ADS)
Liu, Chung-Chiun
Hydrogen propellant leakage poses significant operational problems in the rocket propulsion industry as well as for space exploratory applications. Vigorous efforts have been devoted to minimizing hydrogen leakage in assembly, test, and launch operations related to hydrogen propellant. The objective has been to reduce the operational cost of assembling and maintaining hydrogen delivery systems. Specifically, efforts have been made to develop a hydrogen leak detection system for point-contact measurement. Under the auspices of Lewis Research Center, the Electronics Design Center at Case Western Reserve University, Cleveland, Ohio, has undertaken the development of a point-contact hydrogen gas sensor with potential applications to the hydrogen propellant industry. We envision a sensor array consisting of numbers of discrete hydrogen sensors that can be located in potential leak sites. Silicon-based microfabrication and micromachining techniques are used in the fabrication of these sensor prototypes. Evaluations of the sensor are carried out in-house at Case Western Reserve University as well as at Lewis Research Center and GenCorp Aerojet, Sacramento, California. The hydrogen gas sensor is not only applicable in a hydrogen propulsion system, but also usable in many other civilian and industrial settings. This includes vehicles or facility use, or in the production of hydrogen gas. Dual space and commercial uses of these point-contacted hydrogen sensors are feasible and will directly meet the needs and objectives of NASA as well as various industrial segments.
Anode-cathode power distribution systems and methods of using the same for electrochemical reduction
Koehl, Eugene R; Barnes, Laurel A; Wiedmeyer, Stanley G; Williamson, Mark A; Willit, James L
2014-01-28
Power distribution systems are useable in electrolytic reduction systems and include several cathode and anode assembly electrical contacts that permit flexible modular assembly numbers and placement in standardized connection configurations. Electrical contacts may be arranged at any position where assembly contact is desired. Electrical power may be provided via power cables attached to seating assemblies of the electrical contacts. Cathode and anode assembly electrical contacts may provide electrical power at any desired levels. Pairs of anode and cathode assembly electrical contacts may provide equal and opposite electrical power; different cathode assembly electrical contacts may provide different levels of electrical power to a same or different modular cathode assembly. Electrical systems may be used with an electrolyte container into which the modular cathode and anode assemblies extend and are supported above, with the modular cathode and anode assemblies mechanically and electrically connecting to the respective contacts in power distribution systems.
Individual researcher liability for clinical research on humans.
Miller, Ruth K
2003-01-01
Despite international guidelines and federal regulations, a recent rash of problems in clinical trials have highlighted weaknesses in the oversight process. The federal regulatory system depends on self-policing by researchers and institutions. Because the existing system is overworked, applying common law forms of liability to clinical researchers may encourage improvements in this self-regulation. While research necessarily involves uncertainties, researchers have the greatest direct control over the implementation of the research protocol and the most extensive direct contact with subjects, and must bear corresponding responsibility for acts which fall below the standard of care. This paper argues that the existing FDA patient protections should be adopted as the standards of care for researchers. It examines the possible application of negligence, negligence per se, and fraud and misrepresentation claims against researchers.
Leung, Ka-Ngo; Gordon, Keith C.; Kippenham, Dean O.; Purgalis, Peter; Moussa, David; Williams, Malcom D.; Wilde, Stephen B.; West, Mark W.
1989-01-01
A large area directly heated lanthanum hexaboride (LaB.sub.6) cathode system (10) is disclosed. The system comprises a LaB.sub.6 cathode element (11) generally circular in shape about a central axis. The cathode element (11) has a head (21) with an upper substantially planar emission surface (23), and a lower downwardly and an intermediate body portion (26) which diminishes in cross-section from the head (21) towards the base (22) of the cathode element (11). A central rod (14) is connected to the base (22) of the cathode element (11) and extends along the central axis. Plural upstanding spring fingers (37) are urged against an outer peripheral contact surface (24) of the head end (21) to provide a mechanical and electrical connection to the cathode element (11).
ERIC Educational Resources Information Center
Orman, Evelyn K.
2016-01-01
This study examined the effects of virtual reality immersion with audio on eye contact, directional focus and focus of attention for novice wind band conductors. Participants (N = 34) included a control group (n = 12) and two virtual reality groups with (n = 10) and without (n = 12) head tracking. Participants completed conducting/score study…
The Background to Current Theories of Scuffing
1973-01-01
attention because, by neglecting axial flow , it can be treated in two dimensions. This has resulted in a fairly complete theoretical analysis...the contact. This method was essentially one of measuring the volume rate of flow through the contact, which was directly related to the pad...exit constriction. The pressure and temperature were also measured in the axial direction (105) and the results indicated that side leakage was
Multifunctional Composites through Inkjet-printed Architectures
2015-03-27
were printed onto prepreg before curing, and remained arrested between composite plies without direct contact with the neighboring micro-droplets after...micro-droplets were printed onto prepreg before curing, and remained arrested between composite plies without direct contact with the neighbouring...unidirectional carbon fibre prepreg (Cycom 977-2, Cytec Industries Inc., USA) was chosen as substrate in this work. Poly(methyl methacrylate) (PMMA) (Mn = 15 kDa
Fabrication and anisotropic wettability of titanium-coated microgrooves
NASA Astrophysics Data System (ADS)
Gui, N.; Xu, W.; Tian, J.; Rosengarten, G.; Brandt, M.; Qian, M.
2018-03-01
Surface wettability plays a critical role in a variety of key areas including orthopaedic implants and chemical engineering. Anisotropy in wettability can arise from surface grooves, which are of particular relevance to orthopaedic implants because they can mimic collagen fibrils that are the basic components of the extracellular matrix. Titanium (Ti) and its alloys have been widely used for orthopaedic and dental implant applications. This study is concerned with the fabrication of Ti-coated microgrooves with different groove widths and the characterisation of the anisotropy in wettability through measuring water contact angles, compared with both the Wenzel and Cassie models. Experimental results revealed that there existed significant anisotropy in the wettability of Ti-coated microgrooves, and the degree of anisotropy (Δθ) increased with an increasing groove width from 5 μm to 20 μm. On average, the contact angle measured parallel to the groove direction (θ//) was about 50°-60° smaller than that measured perpendicular to the groove direction (θ⊥). In general, the Wenzel model predicted the contact angles along the surface groove direction reasonably, and so did the Cassie model for the contact angles perpendicular to the groove direction. Osteoblast spreading was affected by the anisotropy in wettability, which occurred preferably along, rather than perpendicular to, the groove direction. These findings are informative for the design of Ti implant surfaces when anisotropy in wettability matters.
76 FR 82111 - Airworthiness Directives; The Boeing Company Airplanes
Federal Register 2010, 2011, 2012, 2013, 2014
2011-12-30
.... FOR FURTHER INFORMATION CONTACT: Chris Parker, Aerospace Engineer, Propulsion Branch, ANM-140S, FAA... Information For more information about this AD, contact Chris Parker, Aerospace Engineer, Propulsion Branch...
Yamaguchi, Daichi
2018-06-05
The image quality of laser and multi-function printers that make use of electrophotography depends on the amount of surface charge generated by contact electrification on the toner particles. However, because it has been impossible to experimentally evaluate such amounts under controlled contact conditions using macroscopic measurements, theoretical elucidation of the contact electrification mechanism has not progressed sufficiently. In the present study, we have developed a system to experimentally evaluate the contact electrification of a single particle using atomic force microscopy (AFM) and nanotweezers (microelectromechanical systems (MEMS)-based actuated tweezers). This system performs, in succession, (i) a contact test that makes use of the nanotweezers and three piezoelectric stages, and (ii) an image force measurement using the AFM cantilever. Using this system, contact electrification was evaluated under controlled conditions, such as the contact number and the indentation depth. In addition, differences in contact electrification due to the amount of external surface additives were investigated. The results reveal that a coating with external additives leads to a decrease in the amount of contact electrification due to a reduction in the contact area with the substrate.
NASA Astrophysics Data System (ADS)
Zhu, Keyong; Huang, Yong; Pruvost, Jeremy; Legrand, Jack; Pilon, Laurent
2017-06-01
This study aims to quantify systematically the effect of non-absorbing cap-shaped droplets condensed on the backside of transparent windows on their directional-hemispherical transmittance and reflectance. Condensed water droplets have been blamed to reduce light transfer through windows in greenhouses, solar desalination plants, and photobioreactors. Here, the directional-hemispherical transmittance was predicted by Monte Carlo ray-tracing method. For the first time, both monodisperse and polydisperse droplets were considered, with contact angle between 0 and 180°, arranged either in an ordered hexagonal pattern or randomly distributed on the window backside with projected surface area coverage between 0 and 90%. The directional-hemispherical transmittance was found to be independent of the size and spatial distributions of the droplets. Instead, it depended on (i) the incident angle, (ii) the optical properties of the window and droplets, and on (iii) the droplet contact angle and (iv) projected surface area coverage. In fact, the directional-hemispherical transmittance decreased with increasing incident angle. Four optical regimes were identified in the normal-hemispherical transmittance. It was nearly constant for droplet contact angles either smaller than the critical angle θcr (predicted by Snell's law) for total internal reflection at the droplet/air interface or larger than 180°-θcr. However, between these critical contact angles, the normal-hemispherical transmittance decreased rapidly to reach a minimum at 90° and increased rapidly with increasing contact angles up to 180°-θcr. This was attributed to total internal reflection at the droplet/air interface which led to increasing reflectance. In addition, the normal-hemispherical transmittance increased slightly with increasing projected surface area coverage for contact angle was smaller than θcr. However, it decreased monotonously with increasing droplet projected surface area coverage for contact angle larger than θcr. These results can be used to select the material or surface coating with advantageous surface properties for applications when dropwise condensation may otherwise have a negative effect on light transmittance.
Federal Register 2010, 2011, 2012, 2013, 2014
2013-11-13
... INFORMATION: Background: Allergic contact dermatitis (ACD), a skin reaction characterized by localized redness, swelling, blistering, or itching after direct contact with a skin allergen, is an important public health.... Web site: http://ntp.niehs.nih.gov/go/niceatm . FOR FURTHER INFORMATION CONTACT: Dr. Warren S. Casey...
Al-Arfaj, Ibrahim; Al-Shammari, Ahmad; Al-Subai, Turki; Al-Absi, Ghanim; AlJaffari, Mohammad; Al-Kadi, Ahmad; El Tantawi, Maha; Al-Ansari, Asim
2016-07-01
The risk of dental trauma may increase during sports participation. The purpose of this study was to evaluate the knowledge, attitude, and practices of sports participants concerning sports-related dental trauma and associated emergency/preventive practices. The study included 124 male subjects over 18 years of age participating in contact and non-contact sports in three clubs in the Eastern Province, Saudi Arabia. A questionnaire was used to assess past experience of dental trauma related to sports in addition to the use of a mouth guard and knowledge of related emergency procedures. Outcomes were compared between individuals practicing direct and non-direct contact sports. One third of the participants had experienced dental trauma while playing sports, mostly crown fracture, mobility, and avulsion. Their knowledge of first aid and emergency procedures was inadequate. A significantly higher proportion of non-direct contact sport participants sought the help of a dentist for themselves or others (P = 0.04 and 0.003, respectively). Only 33.9% used mouth guards, with higher odds of mouth guard use associated with participating in direct contact sports and believing a tooth can be lost during sports practice (odds ratio = 5.59 and 5.37, respectively). Educational programs are needed to increase the awareness in sports participants of the risk of dental trauma during sports participation, to improve their knowledge of first aid procedures, and to increase the use of mouth guards.
Process for Nitrogen Oxide Waste Conversion to Fertilizer
NASA Technical Reports Server (NTRS)
Lueck, Dale E. (Inventor); Parrish, Clyde F. (Inventor)
2003-01-01
The present invention describes a process for converting vapor streams from sources containing at least one nitrogen-containing oxidizing agent therein to a liquid fertilizer composition comprising the steps of: a) directing a vapor stream containing at least one nitrogen-containing oxidizing agent to a first contact zone; b) contacting said vapor stream with water to form nitrogen oxide(s) from said at least one nitrogen-containing oxidizing agent; c) directing said acid(s) as a second stream to a second contact zone; d) exposing said second stream to hydrogen peroxide which is present within said second contact zone in a relative amount of at least 0.1% by weight of said second stream within said second contact zone to convert at least some of any nitrogen oxide species or ions other than in the nitrate form present within said second stream to nitrate ion; e) sampling said stream within said second contact zone to determine the relative amount of hydrogen peroxide within said second contact zone; f) adding hydrogen peroxide to said second contact zone when a level of hydrogen peroxide less than 0.1 % by weight in said second stream is determined by said sampling; g) adding a solution comprising potassium hydroxide to said second stream to maintain a pH between 6.0 and 11.0 within said second stream within said second contact zone to form a solution of potassium nitrate; and h) removing said solution of potassium nitrate from said second contact zone.
Process and Equipment for Nitrogen Oxide Waste Conversion to Fertilizer
NASA Technical Reports Server (NTRS)
Lueck, Dale E. (Inventor); Parrish, Clyde F. (Inventor)
2000-01-01
The present invention describes a process for converting vapor streams from sources containing at least one nitrogen-containing oxidizing agent therein to a liquid fertilizer composition comprising the steps of: (1) directing a vapor stream containing at least nitrogen-containing oxidizing agent to a first contact zone; (2) contacting said vapor stream with water to form nitrogen oxide(s) from said at least one nitrogen- containing oxidizing agent; (3) directing said acid(s) as a second stream to a second contact zone; (4) exposing said second stream to hydrogen peroxide which is present within said second contact zone in a relative amount of at least 0.1% by weight of said second stream within said second contact zone to convert at least some of any nitrogen oxide species or ions other than in the nitrite form present within said second stream to nitrate ion; (5) sampling said stream within said second contact zone to determine the relative amount of hydrogen peroxide within said second contact zone; (6) adding hydrogen peroxide to said second contact zone when a level on hydrogen peroxide less than 0.1% by weight in said second stream is determined by said sampling; (7) adding a solution comprising potassium hydroxide to said second stream to maintain a pH between 6.0 and 11.0 within said second stream within said second contact zone to form a solution of potassium nitrate; and (8) removing sais solution of potassium nitrate from said second contact zone.
Apparatus for the production of gel beads containing a biocatalyst
Scott, C.D.; Scott, T.C.; Davison, B.H.
1998-03-19
An apparatus is described for the large-scale and continuous production of gel beads containing a biocatalyst. The apparatus is a columnar system based on the chemical cross-linking of hydrocolloidal gels that contain and immobilize a biocatalyst, the biocatalyst being a microorganism or an enzyme. Hydrocolloidal gels, such as alginate, carrageenan, and a mixture of bone gelatin and modified alginate, provide immobilization matrices that can be used to entrap and retain the biocatalyst while allowing effective contact with substrates and release of products. Such immobilized biocatalysts are generally formulated into small spheres or beads that have high concentrations of the biocatalyst within the gel matrix. The columnar system includes a gel dispersion nozzle submerged in a heated non-interacting liquid, typically an organic liquid, that is immiscible with water to allow efficient formation of spherical gel droplets, the non-interacting liquid having a specific gravity that is less than water so that the gel droplets will fall through the liquid by the force of gravity. The heated non-interacting liquid is in direct contact with a chilled upflowing non-interacting liquid that will provide sufficient residence time for the gel droplets as they fall through the liquid so that they will be cooled below the gelling temperature and form solid spheres. The upflowing non-interacting liquid is in direct contact with an upflowing temperature-controlled aqueous solution containing the necessary chemicals for cross-linking or fixing of the gel beads to add the necessary stability. The flow rates of the two liquid streams can be varied to control the proper residence time in each liquid section to accommodate the production of gel beads of differing settling velocities. A valve is provided for continuous removal of the stabilized gel beads from the bottom of the column. 1 fig.
Apparatus and method for the production of gel beads containing a biocatalyst
Scott, Charles D.; Scott, Timothy C.; Davison, Brian H.
1998-01-01
An apparatus and method for the large-scale and continuous production of gel beads containing a biocatalyst. The apparatus is a columnar system based on the chemical cross-linking of hydrocolloidal gels that contain and immobilize a biocatalyst, the biocatalyst being a microorganism or an enzyme. Hydrocolloidal gels, such as alginate, carrageenan, and a mixture of bone gelatin and modified alginate, provide immobilization matrices that can be used to entrap and retain the biocatalyst while allowing effective contact with substrates and release of products. Such immobilized biocatalysts are generally formulated into small spheres or beads that have high concentrations of the biocatalyst within the gel matrix. The columnar system includes a gel dispersion nozzle submerged in a heated non-interacting liquid, typically an organic liquid, that is immiscible with water to allow efficient formation of spherical gel droplets, the non-interacting liquid having a specific gravity that is less than water so that the gel droplets will fall through the liquid by the force of gravity. The heated non-interacting liquid is in direct contact with a chilled upflowing non-interacting liquid that will provide sufficient residence time for the gel droplets as they fall through the liquid so that they will be cooled below the gelling temperature and form solid spheres. The upflowing non-interacting liquid is in direct contact with an upflowing temperature-controlled aqueous solution containing the necessary chemicals for cross-linking or fixing of the gel beads to add the necessary stability. The flow rates of the two liquid streams can be varied to control the proper residence time in each liquid section to accommodate the production of gel beads of differing settling velocities. A valve is provided for continuous removal of the stabilized gel beads from the bottom of the column.
Apparatus for the production of gel beads containing a biocatalyst
Scott, Charles D.; Scott, Timothy C.; Davison, Brian H.
1998-01-01
An apparatus for the large-scale and continuous production of gel beads containing a biocatalyst. The apparatus is a columnar system based on the chemical cross-linking of hydrocolloidal gels that contain and immobilize a biocatalyst, the biocatalyst being a microorganism or an enzyme. Hydrocolloidal gels, such as alginate, carrageenan, and a mixture of bone gelatin and modified alginate, provide immobilization matrices that can be used to entrap and retain the biocatalyst while allowing effective contact with substrates and release of products. Such immobilized biocatalysts are generally formulated into small spheres or beads that have high concentrations of the biocatalyst within the gel matrix. The columnar system includes a gel dispersion nozzle submerged in a heated non-interacting liquid, typically an organic liquid, that is immiscible with water to allow efficient formation of spherical gel droplets, the non-interacting liquid having a specific gravity that is less than water so that the gel droplets will fall through the liquid by the force of gravity. The heated non-interacting liquid is in direct contact with a chilled upflowing non-interacting liquid that will provide sufficient residence time for the gel droplets as they fall through the liquid so that they will be cooled below the gelling temperature and form solid spheres. The upflowing non-interacting liquid is in direct contact with an upflowing temperature-controlled aqueous solution containing the necessary chemicals for cross-linking or fixing of the gel beads to add the necessary stability. The flow rates of the two liquid streams can be varied to control the proper residence time in each liquid section to accommodate the production of gel beads of differing settling velocities. A valve is provided for continuous removal of the stabilized gel beads from the bottom of the column.
UCSD/FRA non-contact ultrasonic guided-wave system for rail inspection: an update
NASA Astrophysics Data System (ADS)
Coccia, Stefano; Phillips, Robert; Nucera, Claudio; Bartoli, Ivan; Salamone, Salvatore; Lanza di Scalea, Francesco; Fateh, Mahmood; Carr, Gary
2011-04-01
The University of California at San Diego (UCSD), under a Federal Railroad Administration (FRA) Office of Research and Development (R&D) grant, is developing a system for high-speed and non-contact rail defect detection. A prototype has been designed and field tested with the support of Volpe National Transportation Systems Center and ENSCO, Inc. The goal of this project is to develop a rail defect detection system that provides (a) better defect detection reliability (including internal transverse head defects under shelling and vertical split head defects), and (b) higher inspection speed than achievable by current rail inspection systems. This effort is also in direct response to Safety Recommendations issued by the National Transportation Safety Board (NTSB) following the disastrous train derailments at Superior, WI in 1992 and Oneida, NY in 2007 among others. The UCSD prototype uses non-contact ultrasonic probing of the rail head (laser and air-coupled), ultrasonic guided waves, and a proprietary real-time statistical analysis algorithm that maximizes the sensitivity to defects while minimizing false positives. The current design allows potential inspection speeds up to 40 mph, although all field tests have been conducted up to 15 mph so far. This paper summarizes (a) the latest technology development test conducted at the rail defect farm of Herzog, Inc. in St Joseph, MO in June 2010, and (b) the completion of the new Rail Defect Farm facility at the UCSD Camp Elliott Field Station with partial in-kind donations from the Burlington Northern Santa Fe (BNSF) Railway.
NASA Technical Reports Server (NTRS)
Schwartz, Leonard W.
1999-01-01
A method of calculation is presented that allows the simulation of the time-dependent three-dimensional motion of thin liquid layers on solid substrates for systems with finite equilibrium contact angles. The contact angle is a prescribed function of position on the substrate. Similar mathematical models are constructed for substrates with a pattern of roughness. Evolution equations are given, using the lubrication approximation, that include viscous, capillary and disjoining forces. Motion to and from dry substrate regions is made possible by use of a thin energetically-stable wetting layer. We simulate motion on heterogeneous substrates with periodic arrays of high contact-angle patches. Two different problems are treated for heterogenous substrates. The first is spontaneous motion driven only by wetting forces. If the contact-angle difference is sufficiently high, the droplet can find several different stable positions, depending on the previous history of the motion. A second simulation treats a forced cyclical motion. Energy dissipation per cycle for a heterogeneous substrate is found to be larger than for a uniform substrate with the same total energy. The Landau-Levich solution for plate removal from a liquid bath is extended to account for a pattern of roughness on the plate.
Lepley, Casey R; Throckmorton, Gaylord S; Ceen, Richard F; Buschang, Peter H
2011-05-01
The purpose of this study was to explore the contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance. A prospective cross-sectional study was performed on 30 subjects with Class I occlusion. Masticatory performance was measured with the test food Cuttersil (Heraeus Kulzer, South Bend, Ind) and the fractional-sieve technique. Blu-Mousse (Parkell Biomaterials, Farmingdale, NY) bite registrations were used to measure occlusal contact areas. The American Board of Orthodontics occlusal discrepancies were measured on the subjects' dental models. Maximum bite forces were recorded with a custom transducer, and 3-dimensional chewing cycle kinematics were tracked with an opto-electric computer system and Optotrak software (Northern Digital, Waterloo, Ontario, Canada). Masticatory performance was most closely correlated with occlusal contact area, indicating larger contact areas in subjects with better performance. Occlusal contact area and occlusal discrepancies were also related to bite force and chewing cycle kinematics. Maximum bite force was positively related with masticatory performance. Although masticatory performance is related, both directly and indirectly, to a number of morphologic and functional factors, it is most closely related to occlusal factors. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.
Estimating Colloidal Contact Model Parameters Using Quasi-Static Compression Simulations.
Bürger, Vincent; Briesen, Heiko
2016-10-05
For colloidal particles interacting in suspensions, clusters, or gels, contact models should attempt to include all physical phenomena experimentally observed. One critical point when formulating a contact model is to ensure that the interaction parameters can be easily obtained from experiments. Experimental determinations of contact parameters for particles either are based on bulk measurements for simulations on the macroscopic scale or require elaborate setups for obtaining tangential parameters such as using atomic force microscopy. However, on the colloidal scale, a simple method is required to obtain all interaction parameters simultaneously. This work demonstrates that quasi-static compression of a fractal-like particle network provides all the necessary information to obtain particle interaction parameters using a simple spring-based contact model. These springs provide resistances against all degrees of freedom associated with two-particle interactions, and include critical forces or moments where such springs break, indicating a bond-breakage event. A position-based cost function is introduced to show the identifiability of the two-particle contact parameters, and a discrete, nonlinear, and non-gradient-based global optimization method (simplex with simulated annealing, SIMPSA) is used to minimize the cost function calculated from deviations of particle positions. Results show that, in principle, all necessary contact parameters for an arbitrary particle network can be identified, although numerical efficiency as well as experimental noise must be addressed when applying this method. Such an approach lays the groundwork for identifying particle-contact parameters from a position-based particle analysis for a colloidal system using just one experiment. Spring constants also directly influence the time step of the discrete-element method, and a detailed knowledge of all necessary interaction parameters will help to improve the efficiency of colloidal particle simulations.
Lei, Da; Lin, Mian; Li, Yun; Jiang, Wenbin
2018-06-15
An accurate model of the dynamic contact angle θ d is critical for the calculation of capillary force in applications like enhanced oil recovery, where the capillary number Ca ranges from 10 -10 to 10 -5 and the Bond number Bo is less than 10 -4 . The rate-dependence of the dynamic contact angle under such conditions remains blurred, and is the main target of this study. Featuring with pressure control and interface tracking, the innovative experimental system presented in this work achieves the desired ranges of Ca and Bo, and enables the direct optical measurement of dynamic contact angles in capillaries as tiny as 40 × 20 (width × height) μm and 80 × 20 μm. The advancing and receding processes of wetting and nonwetting liquids were tested. The dynamic contact angle was confirmed velocity-independent with 10 -9 < Ca < 10 -5 (contact line velocity V = 0.135-490 μm/s) and it can be described by a two-angle model with desirable accuracy. A modified two-angle model was developed and an empirical form was obtained from experiments. For different liquids contacting the same surface, the advancing angle θ adv approximately equals the static contact angle θ o . The receding angle θ rec was found to be a linear function of θ adv , in good agreement with our and other experiments from the literature. Copyright © 2018 Elsevier Inc. All rights reserved.
NASA Astrophysics Data System (ADS)
Tian, Kaiwen; Goldsby, David L.; Carpick, Robert W.
2018-05-01
Rate and state friction (RSF) laws are widely used empirical relationships that describe macroscale to microscale frictional behavior. They entail a linear combination of the direct effect (the increase of friction with sliding velocity due to the reduced influence of thermal excitations) and the evolution effect (the change in friction with changes in contact "state," such as the real contact area or the degree of interfacial chemical bonds). Recent atomic force microscope (AFM) experiments and simulations found that nanoscale single-asperity amorphous silica-silica contacts exhibit logarithmic aging (increasing friction with time) over several decades of contact time, due to the formation of interfacial chemical bonds. Here we establish a physically based RSF relation for such contacts by combining the thermally activated Prandtl-Tomlinson (PTT) model with an evolution effect based on the physics of chemical aging. This thermally activated Prandtl-Tomlinson model with chemical aging (PTTCA), like the PTT model, uses the loading point velocity for describing the direct effect, not the tip velocity (as in conventional RSF laws). Also, in the PTTCA model, the combination of the evolution and direct effects may be nonlinear. We present AFM data consistent with the PTTCA model whereby in aging tests, for a given hold time, static friction increases with the logarithm of the loading point velocity. Kinetic friction also increases with the logarithm of the loading point velocity at sufficiently high velocities, but at a different increasing rate. The discrepancy between the rates of increase of static and kinetic friction with velocity arises from the fact that appreciable aging during static contact changes the energy landscape. Our approach extends the PTT model, originally used for crystalline substrates, to amorphous materials. It also establishes how conventional RSF laws can be modified for nanoscale single-asperity contacts to provide a physically based friction relation for nanoscale contacts that exhibit chemical bond-induced aging, as well as other aging mechanisms with similar physical characteristics.
Extended release of hyaluronic acid from hydrogel contact lenses for dry eye syndrome.
Maulvi, Furqan A; Soni, Tejal G; Shah, Dinesh O
2015-01-01
Current dry eye treatment includes delivering comfort enhancing agents to the eye via eye drops, but low residence time of eye drops leads to low bioavailability. Frequent administration leads to incompliance in patients, so there is a great need for medical device such as contact lenses to treat dry eye. Studies in the past have demonstrated the efficacy of hyaluronic acid (HA) in the treatment of dry eyes using eye drops. In this paper, we present two methods to load HA in hydrogel contact lenses, soaking method and direct entrapment. The contact lenses were characterized by studying their optical and physical properties to determine their suitability as extended wear contact lenses. HA-laden hydrogel contact lenses prepared by soaking method showed release up to 48 h with acceptable physical and optical properties. Hydrogel contact lenses prepared by direct entrapment method showed significant sustained release in comparison to soaking method. HA entrapped in hydrogels resulted in reduction in % transmittance, sodium ion permeability and surface contact angle, while increase in % swelling. The impact on each of these properties was proportional to HA loading. The batch with 200-μg HA loading showed all acceptable values (parameters) for contact lens use. Results of cytotoxicity study indicated the safety of hydrogel contact lenses. In vivo pharmacokinetics studies in rabbit tear fluid showed dramatic increase in HA mean residence time and area under the curve with lenses in comparison to eye drop treatment. The study demonstrates the promising potential of delivering HA through contact lenses for the treatment of dry eye syndrome.