Sample records for direct contact test

  1. Antibacterial properties of aged dental cements evaluated by direct-contact and agar diffusion tests.

    PubMed

    Lewinstein, Israel; Matalon, Shlomo; Slutzkey, Shimshon; Weiss, Ervin I

    2005-04-01

    Since failure of fixed partial dentures is most frequently caused by caries, it would be advantageous if cements possessed antibacterial properties. The purpose of this study was to evaluate the antibacterial properties of 3 dental cements using the direct-contact test and agar diffusion test. For the direct-contact test, wells (n = 4) of microtiter plates were coated with the tested cements (Harvard cement, Duralon, and Ketac-Cem) while Streptococcus mutans suspension was placed directly on the cements. Bacterial growth was evaluated by a temperature-controlled microplate spectrophotometer. Eight wells of bacteria without the tested cements served as the positive control. Six wells of the tested cement without bacteria served as the negative control. For the agar diffusion test, triplicate specimens of freshly mixed cements were poured into uniform wells (5 mm in diameter) punched in the agar plates inoculated with Streptococcus mutans . After incubation at 37 degrees C for 24 hours, the agar plates were examined for bacterial growth and the diameter of the halo formed in the bacterial lawn was measured. In both tests, each cement was mixed in 2 different powder/liquid ratios. For the direct-contact test, data were initially recorded after 1 hour of incubation. Additional experiments were performed on specimens that were aged for 24 hours, 1 week, 1 month, and 3 months before assessment by either direct-contact test or agar diffusion test. The data were subjected to 1-way ANOVA with the Tukey post hoc test (alpha=.05). Compared with the control group, Duralon and Harvard cements demonstrated antibacterial properties even after 3 months with the direct-contact test (P <.002), while Ketac-Cem exhibited no antibacterial properties. In the agar diffusion test, no antibacterial activity was observed for any of the tested cements. The different powder/liquid ratios had a negligible effect on the antibacterial properties of the tested cements. Within the limitations of this study, Duralon and Harvard cements possessed prolonged antibacterial properties, while Ketac-Cem exhibited no antibacterial activity. The direct-contact test may be a more suitable test than the agar diffusion test to evaluate antibacterial properties of definitive cements.

  2. Development of a Contact Permeation Test Fixture and Method

    DTIC Science & Technology

    2013-04-01

    direct contact with the skin, indicates the need for a quantitative contact test method. Comparison tests were conducted with VX on a standardized...Guide for the Care and Use of Laboratory Animals (8th ed.; National Research Council: Washington, DC, 2011). This test was also performed in...1 1.2 Development of a Contact-Based Permeation Test Method ........................................ 1 2. EXPERIMENTAL PROCEDURES

  3. Non-contact data access with direction identification for industrial differential serial bus

    NASA Astrophysics Data System (ADS)

    Xie, Kai; Li, Xiaoping; Zhang, Hanlu; Yang, Ming; Ye, Yinghao

    2013-06-01

    We propose a non-contact method for accessing data in industrial differential serial bus applications, which could serve as an effective and safe online testing and diagnosing tool. The data stream and the transmission direction are reconstructed simultaneously from the near-field emanations of a twisted pair, eliminating direct contact with the actual conductors, and avoiding damage to the insulation (only the outer sheathing is removed). A non-contact probe with the ability to sense electric and magnetic fields is presented, as are theories for data reconstruction, direction identification, and a circuit implementation. The prototype was built using inexpensive components and then tested on a standard RS-485 industrial serial bus. Experimental results verified the validity of the proposed scheme.

  4. Field tests of 2- and 40-tube condensers at the East Mesa Geothermal Test Site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Murphy, R.W.; Domingo, N.

    1982-05-01

    Two water-cooled isobutane condensers, one with 2 tubes and one with 40 tubes, were subjected to field tests at the East Mesa Geothermal Test Site to assess relative heat transfer performance in both surface evaporator and direct-contact evaporator modes. The five groups of tests established that field performance was below earlier laboratory-determined levels and that direct-contact evaporator mode performance was poorer than that for the surface evaporator mode. In all test situations, fluted condenser tubes performed better than smooth condenser tubes. Cooling water quality had no significant effect on performance, but brine preflash in the direct-contact mode did promote somemore » relative performance improvement. Important implications of these results for binary geothermal power plants are that (1) working-fluid-side impurities can significantly degrade heat transfer performance of the power plant condensers and (2) provisions for minimizing such impurities may be required.« less

  5. Antimicrobial activity of ProRoot MTA in contact with blood

    PubMed Central

    Farrugia, C.; Baca, P.; Camilleri, J.; Arias Moliz, M. T.

    2017-01-01

    Dental materials based on Portland cement, which is used in the construction industry have gained popularity for clinical use due to their hydraulic properties, the interaction with tooth tissue and their antimicrobial properties. The antimicrobial properties are optimal in vitro. However in clinical use contact with blood may affect the antimicrobial properties. This study aims to assess whether antimicrobial properties of the Portland cement-based dental cements such as mineral trioxide aggregate (MTA) are also affected by contact with blood present in clinical situations. ProRoot MTA, a Portland cement-based dental cement was characterized following contact with water, or heparinized blood after 1 day and 7 days aging. The antimicrobial activity under the mentioned conditions was assessed using 3 antimicrobial tests: agar diffusion test, direct contact test and intratubular infection test. MTA in contact with blood was severely discoloured, exhibited an additional phosphorus peak in elemental analysis, no calcium hydroxide peaks and no areas of bacterial inhibition growth in the agar diffusion test were demonstrated. ProRoot MTA showed limited antimicrobial activity, in both the direct contact test and intratubular infection test. When aged in water ProRoot MTA showed higher antimicrobial activity than when aged in blood. Antimicrobial activity reduced significantly after 7 days. Further assessment is required to investigate behaviour in clinical situations. PMID:28128328

  6. Specificity in Sociality: Mice and Prairie Voles Exhibit Different Patterns of Peer Affiliation

    PubMed Central

    Beery, Annaliese K.; Christensen, Jennifer D; Lee, Nicole S.; Blandino, Katrina L.

    2018-01-01

    Social behavior is often described as a unified concept, but highly social (group-living) species exhibit distinct social structures and may make different social decisions. Prairie voles (Microtus ochrogaster) are socially monogamous rodents that often reside in extended family groups, and exhibit robust preferences for familiar social partners (same- and opposite-sex) during extended choice tests, although short-term preferences are not known. Mice (Mus musculus) are gregarious and colonial, but in brief laboratory tests of social preference they typically prefer social novelty. This preference for novel vs. familiar peers may represent a species-specific difference in social decision-making between mice and prairie voles. However, the tests used to measure preferences in each species differ markedly in duration and degree of contact, such that the behaviors cannot be directly compared. We assessed whether social preferences for novelty or familiarity differed between mice and prairie voles of both sexes when assessed with matching protocols: the sociability/social preference test (SPT) typically used in mice (short, no direct contact), and the partner preference test (PPT) used in voles (long, direct contact). A subset of voles also underwent a PPT using barriers (long, no direct contact). In the short SPT, behavior did not differ between species. In the longer test, pronounced partner preferences emerged in prairie voles, but mice exhibited no social preferences and rarely huddled. No sex differences were evident in either test. Direct physical contact was required for partner preferences in huddling time in voles, but preference for the partner chamber was evident with or without contact. Both prairie voles and mice are social, but they exhibit important differences in the specificity and extent of their social behavior. While mice are often used to study social approach and other behaviors, voles are a more suitable species for the study of selective social relationships. Consideration of these differences will be important for studies examining the neural mechanisms supporting different kinds of peer social behavior. PMID:29615879

  7. Direct contact as a moderator of extended contact effects: cross-sectional and longitudinal impact on outgroup attitudes, behavioral intentions, and attitude certainty.

    PubMed

    Christ, Oliver; Hewstone, Miles; Tausch, Nicole; Wagner, Ulrich; Voci, Alberto; Hughes, Joanne; Cairns, Ed

    2010-12-01

    Cross-group friendships (the most effective form of direct contact) and extended contact (i.e., knowing ingroup members who have outgroup friends) constitute two of the most important means of improving outgroup attitudes. Using cross-sectional and longitudinal samples from different intergroup contexts, this research demonstrates that extended contact is most effective when individuals live in segregated neighborhoods having only few, or no, direct friendships with outgroup members. Moreover, by including measures of attitudes and behavioral intentions the authors showed the broader impact of these forms of contact, and, by assessing attitude certainty as one dimension of attitude strength, they tested whether extended contact can lead not only to more positive but also to stronger outgroup orientations. Cross-sectional data showed that direct contact was more strongly related to attitude certainty than was extended contact, but longitudinal data showed both forms of contact affected attitude certainty in the long run.

  8. Evaluation of cytotoxic effects of six self-etching adhesives with direct and indirect contact tests.

    PubMed

    Kusdemir, Mahmut; Gunal, Solen; Ozer, Fusun; Imazato, Satoshi; Izutani, Naomi; Ebisu, Shigeyuki; Blatz, Markus B

    2011-01-01

    This study evaluated the cytotoxicity of self-etching primers/adhesives by direct contact and dentin barrier tests. The three two-step self-etching systems Clearfil SE Bond (CSE), Clearfil Protect Bond (CPB), Prime&Bond NT/NRC (PB) and one-step self-etching systems Reactmer Bond (RB), Clearfil Tri-S Bond (CTS), and Adper Prompt L-Pop (AP) were examined. In direct contact tests, L929 cells were cultured in the presence of diluted solutions (50, 20, 10, and 1%) of primer/conditioner of adhesive systems. For dentin barrier tests, each system was applied onto 0.5 or 1.5 mm thick human dentin assembled in a simple pulp chamber device and incubated for 24 h at 37°C to make the diffusive components contact the L929 cells placed at the bottom of the chamber. The cytotoxic effects were assessed by MTT assay. Cell culture without application of any primers/adhesives served as the control for both tests. One-way ANOVA and Tukey HSD tests were used for statistical analyses. The direct contact tests demonstrated that CSE and CPB were less toxic than the other materials at all dilutions. In the dentin barrier tests, toxic effects of materials were reduced with an increase in thickness of intervening dentin. CSE and CPB showed less cytotoxicity than the other adhesives (p<0.05) when applied to 0.5 mm-thick dentin, and CSE was the least toxic in the 1.5 mm-dentin group (p<0.05). Dentin thickness positively affected biocompatibility of the tested bonding systems. Two-step self-etching systems with HEMA-based primers were more biocompatible than other self-etching adhesives.

  9. 78 FR 23940 - Use of International Standard ISO-10993, “Biological Evaluation of Medical Devices Part 1...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-23

    ... requests for medical devices that come into direct or indirect contact with the human body in order to... the human body in order to determine the potential toxicity resulting from contact of the component... direct or indirect contact with the human body. This document addresses the following issues: (1) Test...

  10. Toxicity of aerosols to larch casebearer larvae

    Treesearch

    Robert L. Lyon; Margaret E. May

    1970-01-01

    Six insecticides were tested in the laboratory as aerosols against larch casebeare1 larvae. Their toxicity was determined by both direct contact and residual contact on filter paper. All six were highly toxic at less than 1.05 µg/ cm2 (the equivalent of 1.5 oz./acre). In decreasing order of toxicity at LD90 (direct contact...

  11. 78 FR 68076 - Request for Information on Alternative Skin Sensitization Test Methods and Testing Strategies and...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-11-13

    ... INFORMATION: Background: Allergic contact dermatitis (ACD), a skin reaction characterized by localized redness, swelling, blistering, or itching after direct contact with a skin allergen, is an important public health.... Web site: http://ntp.niehs.nih.gov/go/niceatm . FOR FURTHER INFORMATION CONTACT: Dr. Warren S. Casey...

  12. Toxic Hazard to the Rabbit from Direct and Vapor Contact with HD-Contaminated Plexiglas, Concrete, or XM40 Nylon Carrier Material

    DTIC Science & Technology

    1986-07-01

    for vapor transfer. A toxicological test was c’isigned to evaluate the above models. Animals were exposed to agant vapor and to direct contact with...surfaces contaminated with HD. If the toxicological response is the same from direct contact as from vapor, then only vapor transfer is significant...study were chosen to deter- mine whether partitioning is applicable to nonpermeable materials such as the polymethyl methacrylate ( PMMA ) sheeting or to

  13. Air/molten salt direct-contact heat-transfer experiment and economic analysis

    NASA Astrophysics Data System (ADS)

    Bohn, M. S.

    1983-11-01

    Direct-contact heat-transfer coefficients have been measured in a pilot-scale packed column heat exchanger for molten salt/air duty. Two types of commercial tower packings were tested: metal Raschig rings and initial Pall rings. Volumetric heat-transfer coefficients were measured and appeared to depend upon air flow but not on salt flow rate. An economic analysis was used to compare the cost-effectiveness of direct-contact heat exchange with finned-tube heat exchanger in this application. Incorporating the measured volumetric heat-transfer coefficients, a direct-contact system appeared to be from two to five times as cost-effective as a finned-tube heat exchanger, depending upon operating temperature. The large cost advantage occurs for higher operating temperatures (2700(0)C), where high rates of heat transfer and flexibility in materials choice give the cost advantage to the direct-contact heat exchanger.

  14. Heat transfer characteristics of a surface type direct contact boiler

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Deeds, R.S.; Jacobs, H.R.; Boehm, R.F.

    1976-03-01

    Two direct contact heat exchangers were constructed and test results were obtained using water and refrigerant 113 as the working fluids. The heat exchangers were operated in a three-phase mode; the water remained liquid throughout the vessel and the liquid refrigerant 113 underwent vaporization following direct injection into the water. The effect of important operational parameters--operating heights, refrigerant 113 injection techniques, mass flow ratios, and temperatures--was studied to determine generalized trends important in the design and operation of a prototype three-phase direct contact heat exchanger. The primary system used in this study performed well overall. The initial favorable results ofmore » this study warrant further investigation of direct contact heat exchange as a means of utilizing geothermal energy.« less

  15. Human-directed social behaviour in dogs shows significant heritability.

    PubMed

    Persson, M E; Roth, L S V; Johnsson, M; Wright, D; Jensen, P

    2015-04-01

    Through domestication and co-evolution with humans, dogs have developed abilities to attract human attention, e.g. in a manner of seeking assistance when faced with a problem solving task. The aims of this study were to investigate within breed variation in human-directed contact seeking in dogs and to estimate its genetic basis. To do this, 498 research beagles, bred and kept under standardized conditions, were tested in an unsolvable problem task. Contact seeking behaviours recorded included both eye contact and physical interactions. Behavioural data was summarized through a principal component analysis, resulting in four components: test interactions, social interactions, eye contact and physical contact. Females scored significantly higher on social interactions and physical contact and age had an effect on eye contact scores. Narrow sense heritabilities (h(2) ) of the two largest components were estimated at 0.32 and 0.23 but were not significant for the last two components. These results show that within the studied dog population, behavioural variation in human-directed social behaviours was sex dependent and that the utilization of eye contact seeking increased with age and experience. Hence, heritability estimates indicate a significant genetic contribution to the variation found in human-directed social interactions, suggesting that social skills in dogs have a genetic basis, but can also be shaped and enhanced through individual experiences. This research gives the opportunity to further investigate the genetics behind dogs' social skills, which could also play a significant part into research on human social disorders such as autism. © 2015 John Wiley & Sons Ltd and International Behavioural and Neural Genetics Society.

  16. Experiences in extraction of contact parameters from process-evaluation test-structures

    NASA Technical Reports Server (NTRS)

    Lieneweg, Udo

    1988-01-01

    Six-terminal-contact test structures are introduced for characterizing ohmic contacts between a metal and a heavily doped semiconductor layer. Specifically, the six-terminal test structure supplies the additional information needed in order to calculate the transmission length and eventual corrections to the characteristic resistance per unit width due to finite contact length. The essential feature of this test structure is a square contact with four taps in the lower (semiconductor) layer. Every other one of these taps is used for current injection ('front'). From the voltage drop at the opposite tap and the side taps, the 'end' resistance and the 'side' resistances are calculated. The test structures are shown to give valuable information complementary to the common front resistance measurements. The interfacial resistivity is obtained directly after proper correction for flange effects.

  17. Patterns of direct and indirect contact between cattle and badgers naturally infected with tuberculosis.

    PubMed

    Drewe, J A; O'Connor, H M; Weber, N; McDonald, R A; Delahay, R J

    2013-07-01

    Tuberculosis (TB) due to infection with Mycobacterium bovis is transmitted between cattle and badgers (Meles meles) in the UK and Ireland but it is unclear where or when transmission occurs. We investigated direct and indirect interactions between badgers and cattle using automated proximity loggers on animals and at badger latrines located on pasture, in an area of south-west England with a high-density badger population. Direct contacts (interactions within 1.4 m) between badgers and cattle at pasture were very rare (four out of >500000 recorded animal-to-animal contacts) despite ample opportunity for interactions to occur. Indirect interactions (visits to badger latrines by badgers and cattle) were two orders of magnitude more frequent than direct contacts: 400 visits by badgers and 1700 visits by cattle were recorded. This suggests that indirect contacts might be more important than direct contacts in terms of disease transmission at pasture. The TB infection status of individual badgers (ascribed with 93% accuracy using three diagnostic tests) did not affect the frequency or duration of their visits to latrines located on pasture grazed by cattle. Nevertheless, there was wide variation in contact behaviour between individuals, which highlights the importance of understanding heterogeneity in contact patterns when developing strategies to control disease spread in wildlife and livestock.

  18. Direct Contact Heat Exchange Interfacial Phenomena for Liquid Metal Reactors: Part II - Void Fraction

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Abdulla, S.; Liu, X.; Anderson, M.H.

    One concept being considered for steam generation in innovative nuclear reactor applications, involves water coming into direct contact with a circulating molten metal. The vigorous agitation of the two fluids, the direct liquid-liquid contact and the consequent large interfacial area can give rise to large heat transfer coefficients and rapid steam generation. For an optimum design of such direct contact heat exchange and vaporization systems, detailed knowledge is necessary of the various flow regimes, interfacial transport phenomena, heat transfer and operational stability. In order to investigate the interfacial transport phenomena, heat transfer and operational stability of direct liquid-liquid contact, amore » series of experiments are being performed in a 1-d test facility at Argonne National Laboratory and a 2-d experimental facility at UW-Madison. Each of the experimental facilities primarily consist of a liquid-metal melt chamber, heated test section (10 cm diameter tube for 1-d facility and 10 cm 50 cm rectangle for 2-d facility), water injection system and steam suppression tank. This paper is part II which, primarily addresses results and analysis of a set of preliminary experiments and void fraction measurements conducted in the 2-d facility at UW-Madison, part I deals with the heat transfer in the 1-d test facility at Argonne National Laboratory. A real-time high energy X-ray imaging system was developed and utilized to visualize the multiphase flow and measure line-average local void fractions, time-dependent void fraction distribution as well as estimates of the vapor bubble sizes and velocities. These measurements allowed us to determine the volumetric heat transfer coefficient and gain insight into the local heat transfer mechanisms. In this study, the images were captured at frame rates of 100 fps with spatial resolution of about 7 mm with a full-field view of a 15 cm square and five different positions along the test section height. The full-field average void fraction increases rapidly to about 15% in these preliminary tests, with the apparent boiling length of less than 20 cm. The volumetric heat transfer coefficient between the liquid metal and water are compared to the CRIEPI data, the only prior data for direct contact heat exchange for these liquid metal/water systems. (authors)« less

  19. Determination of diffusion and partition coefficients of model migrants by direct contact and vapour phase transfer from low-density polyethylene films into cake.

    PubMed

    Paseiro-Cerrato, Rafael; Rodríguez-Bernaldo de Quirós, Ana; Otero-Pazos, Pablo; Sendón, Raquel; Paseiro-Losada, Perfecto

    2018-03-01

    The aim of the present study was to determine the migration kinetics of one photoinitiator, benzophenone, and two optical brighteners, Uvitex OB and 1,4-diphenyl-1,3-butadiene (DPBD), from low-density polyethylene (LDPE) films into cake. Transfer was assessed by both direct contact and also the vapour phase. To perform the migration tests by direct contact, plastic films enriched with the additives were placed between two cake slices. To evaluate the migration through the gas phase, cake and the fortified LDPE film were placed with no direct contact in a glass container that was hermetically closed. Samples were stored at different time-temperature conditions. Target compounds were extracted from the films with ethanol (70°C, 24 h) and analysed by HPLC-DAD. Relevant parameters such as partition and diffusion coefficients between food and plastic film were calculated. The Arrhenius equation was applied to estimate the diffusion coefficient at any temperature. The data indicate that migration of benzophenone occurs in a significant extent into cake by both direct contact and through the gas phase (no direct contact). Conversely, very little migration occurred for Uvitex OB by direct contact and none through the gas phase. Results for benzophenone suggest that migration through the gas phase should be considered when evaluating migration from food packaging materials into food.

  20. The Cost of Being Watched: Stroop Interference Increases under Concomitant Eye Contact

    ERIC Educational Resources Information Center

    Conty, Laurence; Gimmig, David; Belletier, Clement; George, Nathalie; Huguet, Pascal

    2010-01-01

    Current models in social neuroscience advance that eye contact may automatically recruit cognitive resources. Here, we directly tested this hypothesis by evaluating the distracting strength of eye contact on concurrent visual processing in the well-known Stroop's paradigm. As expected, participants showed stronger Stroop interference under…

  1. Simulation and characterization of a laterally-driven inertial micro-switch

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chen, Wenguo; Wang, Yang; Wang, Huiying

    2015-04-15

    A laterally-driven inertial micro-switch was designed and fabricated using surface micromachining technology. The dynamic response process was simulated by ANSYS software, which revealed the vibration process of movable electrode when the proof mass is shocked by acceleration in sensitive direction. The test results of fabricated inertial micro-switches with and without anti-shock beams indicated that the contact process of micro-switch with anti-shock beams is more reliable than the one without anti-shock beams. The test results indicated that three contact signals had been observed in the contact process of the inertial switch without anti-shock beams, and only one contact signal in themore » inertial switch with anti-shock beams, which demonstrated that the anti-shock beams can effectively constrain the vibration in non-sensitive direction.« less

  2. The biocompatibility of modified experimental Portland cements with potential for use in dentistry.

    PubMed

    Camilleri, J

    2008-12-01

    To evaluate the biocompatibility of a group of new potential dental materials and their eluants by assessing cell viability. Calcium sulpho-aluminate cement (CSA), calcium fluoro-aluminate cement (CFA) and glass-ionomer cement (GIC; Ketac Molar), used as the control, were tested for biocompatibility. Using a direct test method cell viability was measured quantitatively using alamarBluetrade mark dye, and an indirect test method where cells were grown on material elutions and cell viability was assessed using methyltetrazolium (MTT) assay as recommended by ISO 10 993-Part 5 for in vitro testing. Statistical analysis was performed by analysis of variance and Tukey multi-comparison test method. Elution collected from the prototype cements and the GIC cured for 1 and 7 days allowed high cell activity after 24 h cell exposure, which reduced after 48 h when compared to the nontoxic glass-ionomer control, but increased significantly after 72 h cell contact. Elutions collected after 28 days revealed reduced cell activity at all cell exposure times. Cells placed in direct contact with the prototype materials showed reduced cell activity when compared with the control. Cell growth was poor when seeded in direct contact with the prototype cements. GIC encouraged cell growth after 1 day of contact. The eluted species for all the cements tested exhibited adequate cell viability in the early ages with reduced cell activity at 28 days. Changes in the production of calcium hydroxide as a by-product of cement hydration affect the material biocompatibility adversely.

  3. Contact resistance evolution of highly cycled, lightly loaded micro-contacts

    NASA Astrophysics Data System (ADS)

    Stilson, Christopher; Coutu, Ronald

    2014-03-01

    Reliable microelectromechanical systems (MEMS) switches are critical for developing high performance radio frequency circuits like phase shifters. Engineers have attempted to improve reliability and lifecycle performance using novel contact metals, unique mechanical designs and packaging. Various test fixtures including: MEMS devices, atomic force microscopes (AFM) and nanoindentors have been used to collect resistance and contact force data. AFM and nanoindentor test fixtures allow direct contact force measurements but are severely limited by low resonance sensors, and therefore low data collection rates. This paper reports the contact resistance evolution results and fabrication of thin film, sputtered and evaporated gold, micro-contacts dynamically tested up to 3kHz. The upper contact support structure consists of a gold surface micromachined, fix-fix beam designed with sufficient restoring force to overcome adhesion. The hemisphere-upper and planar-lower contacts are mated with a calibrated, external load resulting in approximately 100μN of contact force and are cycled in excess of 106 times or until failure. Contact resistance is measured, in-situ, using a cross-bar configuration and the entire apparatus is isolated from external vibration and housed in an enclosure to minimize contamination due to ambient environment. Additionally, contact cycling and data collection are automated using a computer and LabVIEW. Results include contact resistance measurements of 6 and 8 μm radius contact bumps and lifetime testing up to 323.6 million cycles.

  4. Compatibility tests of materials for a lithium-cooled space power reactor concept

    NASA Technical Reports Server (NTRS)

    Sinclair, J. H.

    1973-01-01

    Materials for a lithium-cooled space power reactor concept must be chemically compatible for up to 50,000 hr at high temperature. Capsule tests at 1040 C (1900 F) were made of material combinations of prime interest: T-111 in direct contact with uranium mononitride (UN), Un in vacuum separated from T-111 by tungsten wire, UN with various oxygen impurity levels enclosed in tungsten wire lithium-filled T-111 capsules, and TZM and lithium together in T-111 capsules. All combinations were compatible for over 2800 hr except for T-111 in direct contact with UN.

  5. Contact Dermatitis in Pediatrics.

    PubMed

    Pelletier, Janice L; Perez, Caroline; Jacob, Sharon E

    2016-08-01

    Contact dermatitis is an umbrella term that describes the skin's reaction to contacted noxious or allergenic substances. The two main categories of contact dermatitis are irritant type and allergic type. This review discusses the signs, symptoms, causes, and complications of contact dermatitis. It addresses the testing, treatment, and prevention of contact dermatitis. Proper management of contact dermatitis includes avoidance measures for susceptible children. Implementation of a nickel directive (regulating the use of nickel in jewelry and other products that come into contact with the skin) could further reduce exposure to the most common allergens in the pediatric population. [Pediatr Ann. 2016;45(8):e287-e292.]. Copyright 2016, SLACK Incorporated.

  6. The Effect of Pile-Up and Contact Area on Hardness Test by Nanoindentation

    NASA Astrophysics Data System (ADS)

    Miyake, Koji; Fujisawa, Satoru; Korenaga, Atsushi; Ishida, Takao; Sasaki, Shinya

    2004-07-01

    We used atomic force microscopy (AFM) for the indentation test evaluating the indentation hardness of materials in the nanometer range. BK7, fused silica, and single-crystal silicon were used as test sample materials. The data analysis processes used to determine the contact area were important in evaluating the indentation hardness of the materials. The direct measurement of the size of the residual hardness impression was useful in evaluating the contact area even in the nanometer region. The results led us to conclude that AFM indentation using a sharp indenter is a powerful method for estimating the indentation hardness in the nanometer range.

  7. 77 FR 14022 - Guidance for Industry: Testing for Salmonella Species in Human Foods and Direct-Human-Contact...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-08

    ... not apply to egg producers and other persons who are covered by FDA's final rule ``Prevention of Salmonella Enteritidis in Shell Eggs During Production, Storage, and Transportation.'' The guidance addresses testing procedures for Salmonella species (spp.) in human foods (except shell eggs) and direct-human...

  8. Preliminary Test Results of a Non-Contacting Finger Seal on a Herringbone-Grooved Rotor

    NASA Technical Reports Server (NTRS)

    Proctor, Margaret P.; Degado, Irebert R.

    2008-01-01

    Low leakage, non-contacting finger seals have potential to reduce gas turbine engine specific fuel consumption by 2 to 3 percent and to reduce direct operating costs by increasing the time between engine overhauls. A non-contacting finger seal with concentric lift-pads operating adjacent to a test rotor with herringbone grooves was statically tested at 300, 533, and 700 K inlet air temperatures at pressure differentials up to 576 kPa. Leakage flow factors were approximately 70 percent less than state-of-the-art labyrinth seals. Leakage rates are compared to first order predictions. Initial spin tests at 5000 rpm, 300 K inlet air temperature and pressure differentials to 241 kPa produced no measurable wear.

  9. Electrode holder useful in a corrosion testing device

    DOEpatents

    Murphy, R.J. Jr.; Jamison, D.E.

    1986-08-19

    The present invention is directed to an apparatus and method for holding one or more test electrodes of precisely known exposed surface area. The present invention is particularly useful in a device for determining the corrosion properties of the materials from which the test electrodes have been formed. The present invention relates to a device and method for holding the described electrodes wherein the exposed surface area of the electrodes is only infinitesimally decreased. Further, in the present invention the exposed, electrically conductive surface area of the contact devices is small relative to the test electrode surface area. The holder of the present invention conveniently comprises a device for contacting and engaging each test electrode at two point contacts infinitesimally small in relation to the exposed surface area of the electrodes. 4 figs.

  10. Electrode holder useful in a corrosion testing device

    DOEpatents

    Murphy, Jr., Robert J.; Jamison, Dale E.

    1986-01-01

    The present invention is directed to an apparatus and method for holding one or more test electrodes of precisely known exposed surface area. The present invention is particularly useful in a device for determining the corrosion properties of the materials from which the test electrodes have been formed. The present invention relates to a device and method for holding the described electrodes wherein the exposed surface area of the electrodes is only infinitesimally decreased. Further, in the present invention the exposed, electrically conductive surface area of the contact devices is small relative to the test electrode surface area. The holder of the present invention conveniently comprises a device for contacting and engaging each test electrode at two point contacts infinitesimally small in relation to the exposed surface area of the electrodes.

  11. Contact frequency and cognitive health among older adults in Israel.

    PubMed

    Schwartz, Ella; Khalaila, Rabia; Litwin, Howard

    2018-05-03

    The current study set out to examine the links between contact frequency with one's social network and cognitive health in later life. It assessed both direct and indirect pathways and the possible role of ethnicity in the effect of the social network on cognitive function. We used data from adults aged 50 and above, which was collected in Israel as part of the Survey of Ageing, Retirement and Health (SHARE). A moderated mediation analysis was conducted to test the direct and indirect associations between contact frequency and cognitive function, as well as the moderation of these associations by population group. Three population groups were examined - veteran-Jews, Arabs and immigrants from the former Soviet Union. Contact frequency with the close social milieu was found to be directly positively related to cognitive function. The association was also mediated by depressive symptoms, such that frequent contacts were linked to cognitive health via reduced depressive symptoms. This indirect link differed, however, among the three population groups. Contact frequency is important for cognitive health in the second half of life, and it operates both directly and by decreasing depressive symptoms. However, these links are not found among all ethnic groups and may, therefore, depend on the culture and social norms of each group and the meaning attributed to social ties.

  12. Who is the Usual Suspect? Evidence of a Selection Bias Toward Faces That Make Direct Eye Contact in a Lineup Task

    PubMed Central

    van Golde, Celine; Verstraten, Frans A. J.

    2017-01-01

    The speed and ease with which we recognize the faces of our friends and family members belies the difficulty we have recognizing less familiar individuals. Nonetheless, overconfidence in our ability to recognize faces has carried over into various aspects of our legal system; for instance, eyewitness identification serves a critical role in criminal proceedings. For this reason, understanding the perceptual and psychological processes that underlie false identification is of the utmost importance. Gaze direction is a salient social signal and direct eye contact, in particular, is thought to capture attention. Here, we tested the hypothesis that differences in gaze direction may influence difficult decisions in a lineup context. In a series of experiments, we show that when a group of faces differed in their gaze direction, the faces that were making eye contact with the participants were more likely to be misidentified. Interestingly, this bias disappeared when the faces are presented with their eyes closed. These findings open a critical conversation between social neuroscience and forensic psychology, and imply that direct eye contact may (wrongly) increase the perceived familiarity of a face. PMID:28203355

  13. Contact material optimization and contact physics in metal-contact microelectromechanical systems (MEMS) switches

    NASA Astrophysics Data System (ADS)

    Yang, Zhenyin

    Metal-contact MEMS switches hold great promise for implementing agile radio frequency (RF) systems because of their small size, low fabrication cost, low power consumption, wide operational band, excellent isolation and exceptionally low signal insertion loss. Gold is often utilized as a contact material for metal-contact MEMS switches due to its excellent electrical conductivity and corrosion resistance. However contact wear and stiction are the two major failure modes for these switches due to its material softness and high surface adhesion energy. To strengthen the contact material, pure gold was alloyed with other metal elements. We designed and constructed a new micro-contacting test facility that closely mimic the typical MEMS operation and utilized this facility to efficiently evaluate optimized contact materials. Au-Ni binary alloy system as the candidate contact material for MEMS switches was systematically investigated. A correlation between contact material properties (etc. microstructure, micro-hardness, electrical resistivity, topology, surface structures and composition) and micro-contacting performance was established. It was demonstrated nano-scale graded two-phase Au-Ni film could possibly yield an improved device performance. Gold micro-contact degradation mechanisms were also systematically investigated by running the MEMS switching tests under a wide range of test conditions. According to our quantitative failure analysis, field evaporation could be the dominant failure mode for highfield (> critical threshold field) hot switching; transient thermal-assisted wear could be the dominant failure mode for low-field hot switching; on the other hand, pure mechanical wear and steady current heating (1 mA) caused much less contact degradation in cold switching tests. Results from low-force (50 muN/micro-contact), low current (0.1 mA) tests on real MEMS switches indicated that continuous adsorbed films from ambient air could degrade the switch contact resistance. Our work also contributes to the field of general nano-science and technology by resolving the transfer directionality of field evaporation of gold in atomic force microscope (AFM)/scanning tunneling microscope (STM).

  14. Surface-modified nanoparticles as anti-biofilm filler for dental polymers

    PubMed Central

    Zaltsman, Nathan; Ionescu, Andrei C.; Weiss, Ervin I.; Brambilla, Eugenio; Beyth, Shaul

    2017-01-01

    The objective of the study was to synthesis silica nanoparticles modified with (i) a tertiary amine bearing two t-cinnamaldehyde substituents or (ii) dimethyl-octyl ammonium, alongside the well-studied quaternary ammonium polyethyleneimine nanoparticles. These were to be evaluated for their chemical and mechanical properties, as well for antibacterial and antibiofilm activity. Samples were incorporated in commercial dental resin material and the degree of monomer conversion, mechanical strength, and water contact angle were tested to characterize the effect of the nanoparticles on resin material. Antibacterial activity was evaluated with the direct contact test and the biofilm inhibition test against Streptococcus mutans. Addition of cinnamaldehyde-modified particles preserved the degree of conversion and compressive strength of the base material and increased surface hydrophobicity. Quaternary ammonium functional groups led to a decrease in the degree of conversion and to low compressive strength, without altering the hydrophilic nature of the base material. In the direct contact test and the anti-biofilm test, the polyethyleneimine particles exhibited the strongest antibacterial effect. The cinnamaldehyde-modified particles displayed antibiofilm activity, silica particles with quaternary ammonium were ineffective. Immobilization of t-cinnamaldehyde onto a solid surface via amine linkers provided a better alternative to the well-known quaternary ammonium bactericides. PMID:29244848

  15. Delamination Detection Using Guided Wave Phased Arrays

    NASA Technical Reports Server (NTRS)

    Tian, Zhenhua; Yu, Lingyu; Leckey, Cara

    2016-01-01

    This paper presents a method for detecting multiple delaminations in composite laminates using non-contact phased arrays. The phased arrays are implemented with a non-contact scanning laser Doppler vibrometer (SLDV). The array imaging algorithm is performed in the frequency domain where both the guided wave dispersion effect and direction dependent wave properties are considered. By using the non-contact SLDV array with a frequency domain imaging algorithm, an intensity image of the composite plate can be generated for delamination detection. For the proof of concept, a laboratory test is performed using a non-contact phased array to detect two delaminations (created through quasi-static impact test) at different locations in a composite plate. Using the non-contact phased array and frequency domain imaging, the two impact-induced delaminations are successfully detected. This study shows that the non-contact phased array method is a potentially effective method for rapid delamination inspection in large composite structures.

  16. Does direct human eye contact function as a warning cue for domestic sheep (Ovis aries)?

    PubMed

    Beausoleil, Ngaio J; Stafford, Kevin J; Mellor, David J

    2006-08-01

    Direct eye contact may function as a warning cue during interspecific interactions, and human staring has been shown to influence the behavior of many species. The authors used an arena test to assess whether human staring altered the behavior of domestic sheep (Ovis aries) compared with no human eye contact. Sheep glanced at the staring human's face more often in the first 2 min of the test, indicating that they perceived a difference between the human stimuli. Staring also elicited more locomotor activity and urination than averted gaze. However, there were no differences in fear-related behaviors, suggesting that a staring human did not represent a greater immediate threat than a nonwatching human. These results imply that human staring is a warning cue for domestic sheep, but no more. Without further reinforcement, sheep quickly habituated to the warning cue. ((c) 2006 APA, all rights reserved).

  17. Using a surrogate contact pair to evaluate polyethylene wear in prosthetic knee joints.

    PubMed

    Sanders, Anthony P; Lockard, Carly A; Weisenburger, Joel N; Haider, Hani; Raeymaekers, Bart

    2016-01-01

    With recent improvements to the properties of ultra-high molecular weight polyethylene (UHMWPE) used in joint replacements, prosthetic knee and hip longevity may extend beyond two decades. However, it is difficult and costly to replicate such a long in vivo lifetime using clinically relevant in vitro wear testing approaches such as walking gait joint simulators. We advance a wear test intermediate in complexity between pin-on-disk and knee joint simulator tests. The test uses a surrogate contact pair, consisting of a surrogate femoral and tibial specimen that replicate the contact mechanics of any full-scale knee condyle contact pair. The method is implemented in a standard multi-directional pin-on-disk wear test machine, and we demonstrate its application via a two-million-cycle wear test of three different UHMWPE formulations. Further, we demonstrate the use of digital photography and image processing to accurately quantify fatigue damage based on the reduced transmission of light through a damage area in a UHMWPE specimen. The surrogate contact pairs replicate the knee condyle contact areas within -3% to +12%. The gravimetric wear test results reflect the dose of crosslinking radiation applied to the UHMWPE: 35 kGy yielded a wear rate of 7.4 mg/Mcycles, 55 kGy yielded 1.0 mg/Mcycles, and 75 kGy (applied to a 0.1% vitamin E stabilized UHMWPE) yielded 1.5 mg/Mcycles. A precursor to spalling fatigue is observed and precisely measured in the radiation-sterilized (35 kGy) and aged UHMWPE specimen. The presented techniques can be used to evaluate the high-cycle fatigue performance of arbitrary knee condyle contact pairs under design-specific contact stresses, using existing wear test machines. This makes the techniques more economical and well-suited to standardized comparative testing. © 2015 Wiley Periodicals, Inc.

  18. Short-term direct contact with soil and plant materials leads to an immediate increase in diversity of skin microbiota.

    PubMed

    Grönroos, Mira; Parajuli, Anirudra; Laitinen, Olli H; Roslund, Marja I; Vari, Heli K; Hyöty, Heikki; Puhakka, Riikka; Sinkkonen, Aki

    2018-05-29

    Immune-mediated diseases have increased during the last decades in urban environments. The hygiene hypothesis suggests that increased hygiene level and reduced contacts with natural biodiversity are related to the increase in immune-mediated diseases. We tested whether short-time contact with microbiologically diverse nature-based materials immediately change bacterial diversity on human skin. We tested direct skin contact, as two volunteers rubbed their hands with sixteen soil and plant based materials, and an exposure via fabric packets filled with moss material. Skin swabs were taken before and after both exposures. Next-generation sequencing showed that exposures increased, at least temporarily, the total diversity of skin microbiota and the diversity of Acidobacteria, Actinobacteria, Bacteroidetes, Proteobacteria and Alpha-, Beta- and Gammaproteobacteria suggesting that contact with nature-based materials modify skin microbiome and increase skin microbial diversity. Until now, approaches to cure or prevent immune system disorders using microbe-based treatments have been limited to use of a few microbial species. We propose that nature-based materials with high natural diversity, such as the materials tested here, might be more effective in modifying human skin microbiome, and eventually, in reducing immune system disorders. Future studies should investigate how long-term changes in skin microbiota are achieved and if the exposure induces beneficial changes in the immune system markers. © 2018 The Authors. MicrobiologyOpen published by John Wiley & Sons Ltd.

  19. Design, construction and mechanical optimisation process of electrode with radial current flow in the scala tympani.

    PubMed

    Deman, P R; Kaiser, T M; Dirckx, J J; Offeciers, F E; Peeters, S A

    2003-09-30

    A 48 contact cochlear implant electrode has been constructed for electrical stimulation of the auditory nerve. The stimulating contacts of this electrode are organised in two layers: 31 contacts on the upper surface directed towards the habenula perforata and 17 contacts connected together as one longitudinal contact on the underside. The design of the electrode carrier aims to make radial current flow possible in the cochlea. The mechanical structure of the newly designed electrode was optimised to obtain maximal insertion depth. Electrode insertion tests were performed in a transparent acrylic model of the human cochlea.

  20. Exploring the sensitivity of the zone of inhibition test for leachable biocides from paper and board food contact materials, and improvements thereof.

    PubMed

    Castle, L; Kelly, J; Jickells, S M; Johns, S M; Mountfort, K A

    2012-01-01

    The zone of inhibition method to test the release of biocides from paper and board food contact materials was evaluated. The method tests the paper by placing a small specimen directly onto culture plates of Bacillus subtilis and Aspergillus niger. The principle is that any extractable biocide will diffuse from the paper into the surrounding nutrient medium and so inhibit growth of the microorganism in the vicinity. The test was found to have insufficient sensitivity for assuring food safety, where detection limits for migration at or below the mg l(-1) (parts per million) level are needed. Also, the test does not mimic the actual or foreseeable conditions of use since most paper/board materials are not intended for direct contact with an aqueous medium for up to 3 days at 30°C (B. subtilis) or 25°C (A. niger), which are the incubation conditions used. The sensitivity of the test was increased approximately 100-fold by preparing a concentrated extract of the paper to be tested and applying this extract to the assay via a blank paper carrier. This was done using methanol as a good solvent for most biocides, as a proof of principle. Other solvents or food simulants could be used to mimic the conditions of use intended for the particular paper/board samples under examination, e.g. contact with dry, fatty, aqueous or acidic foods, hot or cold. Twenty-four plain (unconverted) paper and board samples and 100 food packaging samples were evaluated using the modified procedure. The results revealed that the method has been developed to the stage where background cytotoxic action of normal paper constituents gives a weak response. Unlike the original method, therefore, the modified method with its improved sensitivity and the facility to link with the intended food contact conditions may be considered a suitable bioassay screening test to complement chemical analysis of paper/board for composition and migration.

  1. Are diverse societies less cohesive? Testing contact and mediated contact theories.

    PubMed

    McKenna, Sarah; Lee, Eunro; Klik, Kathleen A; Markus, Andrew; Hewstone, Miles; Reynolds, Katherine J

    2018-01-01

    Previous research has demonstrated that there is a negative relationship between ethnic diversity in a local community and social cohesion. Often the way social cohesion is assessed, though, varies across studies and only some aspects of the construct are included (e.g., trust). The current research explores the relationship between diversity and social cohesion across a number of indicators of social cohesion including neighbourhood social capital, safety, belonging, generalized trust, and volunteering. Furthermore, social psychological theories concerning the role of positive contact and its impact on feelings of threat are investigated. Using a sample of 1070 third generation 'majority' Australians and structural equation modelling (SEM), findings suggest ethnic diversity is related to positive intergroup contact, and that contact showed beneficial impacts for some indicators of social cohesion both directly and indirectly through reducing perceived threat. When interethnic contact and perceived threat are included in the model there is no direct negative effect between diversity and social cohesion. The theoretical implications of these findings are outlined including the importance of facilitating opportunities for positive contact in diverse communities.

  2. Are diverse societies less cohesive? Testing contact and mediated contact theories

    PubMed Central

    Lee, Eunro; Klik, Kathleen A.; Markus, Andrew; Hewstone, Miles; Reynolds, Katherine J.

    2018-01-01

    Previous research has demonstrated that there is a negative relationship between ethnic diversity in a local community and social cohesion. Often the way social cohesion is assessed, though, varies across studies and only some aspects of the construct are included (e.g., trust). The current research explores the relationship between diversity and social cohesion across a number of indicators of social cohesion including neighbourhood social capital, safety, belonging, generalized trust, and volunteering. Furthermore, social psychological theories concerning the role of positive contact and its impact on feelings of threat are investigated. Using a sample of 1070 third generation ‘majority’ Australians and structural equation modelling (SEM), findings suggest ethnic diversity is related to positive intergroup contact, and that contact showed beneficial impacts for some indicators of social cohesion both directly and indirectly through reducing perceived threat. When interethnic contact and perceived threat are included in the model there is no direct negative effect between diversity and social cohesion. The theoretical implications of these findings are outlined including the importance of facilitating opportunities for positive contact in diverse communities. PMID:29596501

  3. Contact Prediction for Beta and Alpha-Beta Proteins Using Integer Linear Optimization and its Impact on the First Principles 3D Structure Prediction Method ASTRO-FOLD

    PubMed Central

    Rajgaria, R.; Wei, Y.; Floudas, C. A.

    2010-01-01

    An integer linear optimization model is presented to predict residue contacts in β, α + β, and α/β proteins. The total energy of a protein is expressed as sum of a Cα – Cα distance dependent contact energy contribution and a hydrophobic contribution. The model selects contacts that assign lowest energy to the protein structure while satisfying a set of constraints that are included to enforce certain physically observed topological information. A new method based on hydrophobicity is proposed to find the β-sheet alignments. These β-sheet alignments are used as constraints for contacts between residues of β-sheets. This model was tested on three independent protein test sets and CASP8 test proteins consisting of β, α + β, α/β proteins and was found to perform very well. The average accuracy of the predictions (separated by at least six residues) was approximately 61%. The average true positive and false positive distances were also calculated for each of the test sets and they are 7.58 Å and 15.88 Å, respectively. Residue contact prediction can be directly used to facilitate the protein tertiary structure prediction. This proposed residue contact prediction model is incorporated into the first principles protein tertiary structure prediction approach, ASTRO-FOLD. The effectiveness of the contact prediction model was further demonstrated by the improvement in the quality of the protein structure ensemble generated using the predicted residue contacts for a test set of 10 proteins. PMID:20225257

  4. [Assessment of the sensitizing potency of cosmetic ingredients and commodities. How will the ingredients of cosmetics and commodities be tested in Europe today and tomorrow?].

    PubMed

    Peiser, M; Platzek, T; Luch, A

    2012-03-01

    Cosmetics and certain commodities are applied or used by consumers directly on the skin. Creams may remain on the skin for longer periods, hair is dyed multiple times per year, nickel ions can be released from studs and piercings in areas of skin damage or migrate from toy materials into the skin of children. Accordingly, using or handling such products always entails a risk for developing a contact allergy. Moreover, daily usage and repeated contacts to certain cosmetics and commodities might lead to repeated elicitation of contact eczema in people already sensitized against allergenic ingredients. Unfortunately, contact allergy is not curable. For the assessment of the allergenic potential of chemicals, only testing based on animal experiments was available in the past. In 2003, the 7(th) amendment of the Cosmetics Directive 76/768/EWG laid down a ban on animal testing of cosmetic ingredients and from 2013 a general marketing ban of such products as well. Therefore, the development and validation of non-animal methods for assessing the toxicological endpoint sensitization/allergenic potency of chemicals is a major task for the years ahead and remains equally a challenge for industry and regulatory agencies.

  5. Contact and contagion: Probability of transmission given contact varies with demographic state in bighorn sheep

    PubMed Central

    Manlove, Kezia R.; Cassirer, E. Frances; Plowright, Raina K.; Cross, Paul C.; Hudson, Peter J.

    2018-01-01

    Understanding both contact and probability of transmission given contact are key to managing wildlife disease. However, wildlife disease research tends to focus on contact heterogeneity, in part because the probability of transmission given contact is notoriously difficult to measure. Here, we present a first step towards empirically investigating the probability of transmission given contact in free-ranging wildlife.We used measured contact networks to test whether bighorn sheep demographic states vary systematically in infectiousness or susceptibility to Mycoplasma ovipneumoniae, an agent responsible for bighorn sheep pneumonia.We built covariates using contact network metrics, demographic information and infection status, and used logistic regression to relate those covariates to lamb survival. The covariate set contained degree, a classic network metric describing node centrality, but also included covariates breaking the network metrics into subsets that differentiated between contacts with yearlings, ewes with lambs, and ewes without lambs, and animals with and without active infections.Yearlings, ewes with lambs, and ewes without lambs showed similar group membership patterns, but direct interactions involving touch occurred at a rate two orders of magnitude higher between lambs and reproductive ewes than between any classes of adults or yearlings, and one order of magnitude higher than direct interactions between multiple lambs.Although yearlings and non-reproductive bighorn ewes regularly carried M. ovipneumoniae, our models suggest that a contact with an infected reproductive ewe had approximately five times the odds of producing a lamb mortality event of an identical contact with an infected dry ewe or yearling. Consequently, management actions targeting infected animals might lead to unnecessary removal of young animals that carry pathogens but rarely transmit.This analysis demonstrates a simple logistic regression approach for testing a priori hypotheses about variation in the odds of transmission given contact for free-ranging hosts, and may be broadly applicable for investigations in wildlife disease ecology. PMID:28317104

  6. Contact and contagion: Probability of transmission given contact varies with demographic state in bighorn sheep.

    PubMed

    Manlove, Kezia R; Cassirer, E Frances; Plowright, Raina K; Cross, Paul C; Hudson, Peter J

    2017-07-01

    Understanding both contact and probability of transmission given contact are key to managing wildlife disease. However, wildlife disease research tends to focus on contact heterogeneity, in part because the probability of transmission given contact is notoriously difficult to measure. Here, we present a first step towards empirically investigating the probability of transmission given contact in free-ranging wildlife. We used measured contact networks to test whether bighorn sheep demographic states vary systematically in infectiousness or susceptibility to Mycoplasma ovipneumoniae, an agent responsible for bighorn sheep pneumonia. We built covariates using contact network metrics, demographic information and infection status, and used logistic regression to relate those covariates to lamb survival. The covariate set contained degree, a classic network metric describing node centrality, but also included covariates breaking the network metrics into subsets that differentiated between contacts with yearlings, ewes with lambs, and ewes without lambs, and animals with and without active infections. Yearlings, ewes with lambs, and ewes without lambs showed similar group membership patterns, but direct interactions involving touch occurred at a rate two orders of magnitude higher between lambs and reproductive ewes than between any classes of adults or yearlings, and one order of magnitude higher than direct interactions between multiple lambs. Although yearlings and non-reproductive bighorn ewes regularly carried M. ovipneumoniae, our models suggest that a contact with an infected reproductive ewe had approximately five times the odds of producing a lamb mortality event of an identical contact with an infected dry ewe or yearling. Consequently, management actions targeting infected animals might lead to unnecessary removal of young animals that carry pathogens but rarely transmit. This analysis demonstrates a simple logistic regression approach for testing a priori hypotheses about variation in the odds of transmission given contact for free-ranging hosts, and may be broadly applicable for investigations in wildlife disease ecology. © 2017 The Authors. Journal of Animal Ecology © 2017 British Ecological Society.

  7. Contact and contagion: Probability of transmission given contact varies with demographic state in bighorn sheep

    USGS Publications Warehouse

    Manlove, Kezia R.; Cassirer, E. Frances; Plowright, Raina K.; Cross, Paul C.; Hudson, Peter J.

    2017-01-01

    Understanding both contact and probability of transmission given contact are key to managing wildlife disease. However, wildlife disease research tends to focus on contact heterogeneity, in part because the probability of transmission given contact is notoriously difficult to measure. Here, we present a first step towards empirically investigating the probability of transmission given contact in free-ranging wildlife.We used measured contact networks to test whether bighorn sheep demographic states vary systematically in infectiousness or susceptibility to Mycoplasma ovipneumoniae, an agent responsible for bighorn sheep pneumonia.We built covariates using contact network metrics, demographic information and infection status, and used logistic regression to relate those covariates to lamb survival. The covariate set contained degree, a classic network metric describing node centrality, but also included covariates breaking the network metrics into subsets that differentiated between contacts with yearlings, ewes with lambs, and ewes without lambs, and animals with and without active infections.Yearlings, ewes with lambs, and ewes without lambs showed similar group membership patterns, but direct interactions involving touch occurred at a rate two orders of magnitude higher between lambs and reproductive ewes than between any classes of adults or yearlings, and one order of magnitude higher than direct interactions between multiple lambs.Although yearlings and non-reproductive bighorn ewes regularly carried M. ovipneumoniae, our models suggest that a contact with an infected reproductive ewe had approximately five times the odds of producing a lamb mortality event of an identical contact with an infected dry ewe or yearling. Consequently, management actions targeting infected animals might lead to unnecessary removal of young animals that carry pathogens but rarely transmit.This analysis demonstrates a simple logistic regression approach for testing a priorihypotheses about variation in the odds of transmission given contact for free-ranging hosts, and may be broadly applicable for investigations in wildlife disease ecology.

  8. Clinical measurement of the height of the interproximal contact area in maxillary anterior teeth.

    PubMed

    Sghaireen, Mohd G; Al-Zarea, Bader K; Al-Shorman, Hisham M; Al-Omiri, Mahmoud K

    2013-11-01

    To clinically quantify the apicoincisal height of interproximal areas directly in patients' mouths. Thirty participants (11 females and 9 males, mean age=26±1.5 years) were recruited into this study. Measurement of interproximal contact areas was carried out directly in patients' mouths using digital caliper (TERENSA, USA) with measuring accuracy of 0.01 mm. The interproximal contact areas that were measured are: central incisor to central incisor, central incisor to lateral incisor, lateral incisor to canine, and canine to first premolar on both sides of the jaw. Statistical significance was based on probability values less than 0.05 (p<0.05). The largest contact point was the one present between central incisors and it ranged from 2.9 to 6.5 mm. On the other hand, the contact point between canine and first premolar was the smallest on both sides of the arch and ranged from 0.6 to 2.5 mm. The dimensions of the contact points declined as we move from anterior area backwards. Statistical analysis using t-test showed that there were significant differences between the measurements of interproximal points of each tooth (P<0.05). the apicogingival dimension of the contact point decreased as we moved from anterior to posterior teeth. The contact area between the central incisors was largest and the one between canine and premolar was the smallest. This study is the first to report direct intra-oral clinical measurement of contact points. Clinical evaluation of contact point dimensions using digital caliber is a viable, quick and accurate method to use.

  9. 49 CFR 572.123 - Neck assembly and test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... with respect to the pendulum's longitudinal centerline between 74 degrees and 92 degrees. Within this... direction of preimpact flight with respect to the pendulum's longitudinal centerline between 85 degrees and... contact between the pendulum striker plate and the honeycomb material. (c) Test procedure. The test...

  10. 49 CFR 572.123 - Neck assembly and test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... with respect to the pendulum's longitudinal centerline between 74 degrees and 92 degrees. Within this... direction of preimpact flight with respect to the pendulum's longitudinal centerline between 85 degrees and... contact between the pendulum striker plate and the honeycomb material. (c) Test procedure. The test...

  11. 49 CFR 572.123 - Neck assembly and test procedure.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... with respect to the pendulum's longitudinal centerline between 74 degrees and 92 degrees. Within this... direction of preimpact flight with respect to the pendulum's longitudinal centerline between 85 degrees and... contact between the pendulum striker plate and the honeycomb material. (c) Test procedure. The test...

  12. 49 CFR 572.123 - Neck assembly and test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... with respect to the pendulum's longitudinal centerline between 74 degrees and 92 degrees. Within this... direction of preimpact flight with respect to the pendulum's longitudinal centerline between 85 degrees and... contact between the pendulum striker plate and the honeycomb material. (c) Test procedure. The test...

  13. 49 CFR 572.123 - Neck assembly and test procedure.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... with respect to the pendulum's longitudinal centerline between 74 degrees and 92 degrees. Within this... direction of preimpact flight with respect to the pendulum's longitudinal centerline between 85 degrees and... contact between the pendulum striker plate and the honeycomb material. (c) Test procedure. The test...

  14. Non-contact method for characterization of small size thermoelectric modules.

    PubMed

    Manno, Michael; Yang, Bao; Bar-Cohen, Avram

    2015-08-01

    Conventional techniques for characterization of thermoelectric performance require bringing measurement equipment into direct contact with the thermoelectric device, which is increasingly error prone as device size decreases. Therefore, the novel work presented here describes a non-contact technique, capable of accurately measuring the maximum ΔT and maximum heat pumping of mini to micro sized thin film thermoelectric coolers. The non-contact characterization method eliminates the measurement errors associated with using thermocouples and traditional heat flux sensors to test small samples and large heat fluxes. Using the non-contact approach, an infrared camera, rather than thermocouples, measures the temperature of the hot and cold sides of the device to determine the device ΔT and a laser is used to heat to the cold side of the thermoelectric module to characterize its heat pumping capacity. As a demonstration of the general applicability of the non-contact characterization technique, testing of a thin film thermoelectric module is presented and the results agree well with those published in the literature.

  15. Genotoxicity testing approaches for the safety assessment of substances used in food contact materials prior to their authorization in the European Union.

    PubMed

    Bolognesi, Claudia; Castoldi, Anna F; Crebelli, Riccardo; Barthélémy, Eric; Maurici, Daniela; Wölfle, Detlef; Volk, Katharina; Castle, Laurence

    2017-06-01

    Food contact materials are all materials and articles intended to come directly or indirectly into contact with food. Before being included in the positive European "Union list" of authorized substances (monomers, other starting substances and additives) for plastic food contact materials, the European Food Safety Authority (EFSA) must assess their safety "in use". If relevant for risk, the safety of the main impurities, reaction and degradation products originating from the manufacturing process is also evaluated. Information on genotoxicity is always required irrespective of the extent of migration and the resulting human exposure, in view of the theoretical lack of threshold for genotoxic events. The 2008 EFSA approach, requiring the testing of food contact materials in three in vitro mutagenicity tests, though still acceptable, is now superseded by the 2011 EFSA Scientific Committee's recommendation for only two complementary tests including a bacterial gene mutation test and an in vitro micronucleus test, to detect two main genetic endpoints (i.e., gene mutations and chromosome aberrations). Follow-up of in vitro positive results depends on the type of genetic effect and on the substance's systemic availability. In this study, we provide an analysis of the data on genotoxicity testing gathered by EFSA on food contact materials for the period 1992-2015. We also illustrate practical examples of the approaches that EFSA took when evaluating "non standard" food contact chemicals (e.g., polymeric additives, oligomer or other reaction mixtures, and nanosubstances). Additionally, EFSA's experience gained from using non testing methods and/or future possibilities in this area are discussed. Environ. Mol. Mutagen. 58:361-374, 2017. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  16. Application of Contact Mode AFM to Manufacturing Processes

    NASA Astrophysics Data System (ADS)

    Giordano, Michael A.; Schmid, Steven R.

    A review of the application of contact mode atomic force microscopy (AFM) to manufacturing processes is presented. A brief introduction to common experimental techniques including hardness, scratch, and wear testing is presented, with a discussion of challenges in the extension of manufacturing scale investigations to the AFM. Differences between the macro- and nanoscales tests are discussed, including indentation size effects and their importance in the simulation of processes such as grinding. The basics of lubrication theory are presented and friction force microscopy is introduced as a method of investigating metal forming lubrication on the nano- and microscales that directly simulates tooling/workpiece asperity interactions. These concepts are followed by a discussion of their application to macroscale industrial manufacturing processes and direct correlations are made.

  17. Design, Development, Testing, and Evaluation: Human Factors Engineering

    NASA Technical Reports Server (NTRS)

    Adelstein, Bernard; Hobbs, Alan; OHara, John; Null, Cynthia

    2006-01-01

    While human-system interaction occurs in all phases of system development and operation, this chapter on Human Factors in the DDT&E for Reliable Spacecraft Systems is restricted to the elements that involve "direct contact" with spacecraft systems. Such interactions will encompass all phases of human activity during the design, fabrication, testing, operation, and maintenance phases of the spacecraft lifespan. This section will therefore consider practices that would accommodate and promote effective, safe, reliable, and robust human interaction with spacecraft systems. By restricting this chapter to what the team terms "direct contact" with the spacecraft, "remote" factors not directly involved in the development and operation of the vehicle, such as management and organizational issues, have been purposely excluded. However, the design of vehicle elements that enable and promote ground control activities such as monitoring, feedback, correction and reversal (override) of on-board human and automation process are considered as per NPR8705.2A, Section 3.3.

  18. The effects of self-directed home exercise with serial telephone contacts on physical functions and quality of life in elderly people at high risk of locomotor dysfunction.

    PubMed

    Aoki, Kana; Sakuma, Mayumi; Ogisho, Noriyuki; Nakamura, Kozo; Chosa, Etsuo; Endo, Naoto

    2015-01-01

    Exercise is essential for maintaining quality of life (QOL) in elderly individuals. However, adherence to exercise programs is low. Here, we assessed the effectiveness of a self-directed home exercise program with serial telephone contacts to encourage exercise adherence among elderly individuals at high risk of locomotor dysfunction. We recruited community-dwelling adults (ァ65 years) in Niigata, Japan, who were targets of the long-term care prevention project for locomotor dysfunction but did not participate in the government-sponsored prevention programs. The study was conducted from November 2011 to October 2012. Participants received exercise instruction and performed exercises independently for 3 months with serial telephone contacts. The single-leg stance and five-times sit-to-stand tests were used to assess physical function. The SF-8 was used to measure health-related QOL. Ninety-seven participants were enrolled in the study, representing 2.5% of eligible people;87 completed the intervention. Scores from physical function tests were significantly improved by the intervention, as were 7 of eight SF-8 subscales. Adherence was 85.4% for the single-leg standing exercise and 82.1% for squatting. Thus, self-directed home exercise with serial telephone contacts improved physical function and health-related QOL, representing a promising model for preventing the need for long-term care due to locomotor dysfunction.

  19. 77 FR 24353 - Airworthiness Directives; Bombardier, Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-04-24

    ... by multiple reports of short circuit events during pre- delivery inspections and test flights, one of... during pre-delivery inspections and test flights, one of which resulted in smoke in the cockpit. We are... INFORMATION CONTACT: Assata Dessaline, Aerospace Engineer, Avionics and Flight Test Branch, ANE-172, New York...

  20. Chemical Composition, Modulatory Bacterial Resistance and Antimicrobial Activity of Essential Oil the Hyptis martiusii Benth by Direct and Gaseous Contact

    PubMed Central

    de Oliveira, Allan Demetrius Leite; Galvao Rodrigue, Fabiola Fernandes; Douglas Melo Coutinho, Henrique; da Costa, Jose Galberto Martins; de Menezes, Irwin Rose Alencar

    2014-01-01

    Background: Several studies have shown that species of the genus Hyptis, have promising antimicrobial and antifungal effects. Objectives: Identify of chemical constituents of essential oil from leaves of Hyptis martiusii and evaluate its effect against bacterial strains by direct and gaseous contact. Materials and Methods: Essential oil was extracted from leaves of Hyptis martiusii Benth using hydro-distillation, and its composition was determined using gas chromatography–mass spectrometry (GC-MS). Chemical analysis showed that there was a predominance of sesquiterpenes. The leaf essential oil was screened for its minimal inhibitory concentration and modulatory effect of aminoglycoside by the direct (MIC) and gaseous (MID) micro-dilution assays for various pathogenic microorganisms. The essential oil remarkably inhibited the growth of all of the tested bacteria (MIC < 512 μg/mL) except S. aureus (SA358) multidrug resistant (MRSA) by direct contact. Results: Twenty-four compounds representing 92.13% of the essential oil of leaves were characterized; δ -3-carene (6.88%), 1, 8-cineole (7.01%), trans-caryophyllene (9.21%), Cariophyllene oxide (7.47%) and bicyclogermacrene (10.61%) were found as the major components. Modulatory aminoglycoside effect, by direct contact, was showed antagonistic relationship with antimicrobial activity. The gaseous component of the oil inhibited the bacterial growth of all of the tested bacteria in 50% and 25% of oil concentration and demonstrated synergistic interactions can be attributed to the constituting the oil compounds. Conclusions: These results show that this oil influences the activity of the antibiotic and may be used as an adjuvant in the antibiotic therapy of respiratory tract bacterial pathogens. PMID:25237640

  1. Mechanical characterization of soft materials using transparent indenter testing system and finite element simulation

    NASA Astrophysics Data System (ADS)

    Xuan, Yue

    Background. Soft materials such as polymers and soft tissues have diverse applications in bioengineering, medical care, and industry. Quantitative mechanical characterization of soft materials at multiscales is required to assure that appropriate mechanical properties are presented to support the normal material function. Indentation test has been widely used to characterize soft material. However, the measurement of in situ contact area is always difficult. Method of Approach. A transparent indenter method was introduced to characterize the nonlinear behaviors of soft materials under large deformation. This approach made the direct measurement of contact area and local deformation possible. A microscope was used to capture the contact area evolution as well as the surface deformation. Based on this transparent indenter method, a novel transparent indentation measurement systems has been built and multiple soft materials including polymers and pericardial tissue have been characterized. Seven different indenters have been used to study the strain distribution on the contact surface, inner layer and vertical layer. Finite element models have been built to simulate the hyperelastic and anisotropic material behaviors. Proper material constants were obtained by fitting the experimental results. Results.Homogeneous and anisotropic silicone rubber and porcine pericardial tissue have been examined. Contact area and local deformation were measured by real time imaging the contact interface. The experimental results were compared with the predictions from the Hertzian equations. The accurate measurement of contact area results in more reliable Young's modulus, which is critical for soft materials. For the fiber reinforced anisotropic silicone rubber, the projected contact area under a hemispherical indenter exhibited elliptical shape. The local surface deformation under indenter was mapped using digital image correlation program. Punch test has been applied to thin films of silicone rubber and porcine pericardial tissue and results were analyzed using the same method. Conclusions. The transparent indenter testing system can effectively reduce the material properties measurement error by directly measuring the contact radii. The contact shape can provide valuable information for the anisotropic property of the material. Local surface deformation including contact surface, inner layer and vertical plane can be accurately tracked and mapped to study the strain distribution. The potential usage of the transparent indenter measurement system to investigate biological and biomaterials was verified. The experimental data including the real-time contact area combined with the finite element simulation would be powerful tool to study mechanical properties of soft materials and their relation to microstructure, which has potential in pathologies study such as tissue repair and surgery plan. Key words: transparent indenter, large deformation, soft material, anisotropic.

  2. Characterization of micro-contact resistance between a gold nanocrystalline line and a tungsten electrode probe in interconnect fatigue testing.

    PubMed

    Ling, Xue; Wang, Yusheng; Li, Xide

    2014-10-01

    An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects of the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li-Etsion-Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.

  3. Characterization of micro-contact resistance between a gold nanocrystalline line and a tungsten electrode probe in interconnect fatigue testing

    NASA Astrophysics Data System (ADS)

    Ling, Xue; Wang, Yusheng; Li, Xide

    2014-10-01

    An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects of the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li-Etsion-Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.

  4. Attitudes Towards Seeking Psychological Help: An Integrative Model Based on Contact, Essentialist Beliefs About Mental Illness, and Stigma.

    PubMed

    Hantzi, Alexandra; Anagnostopoulos, Fotios; Alexiou, Eva

    2018-06-16

    Based on intergroup contact theory, a proposed comprehensive model of attitudes towards seeking professional psychological help was tested, including both potential barriers to mental health help-seeking (i.e., public stigma and self-stigma of seeking help, prejudicial and essentialist beliefs about mental illness, intergroup anxiety) and potential facilitators (i.e., direct and extended contact with persons with mental illness). Relevant measures were completed by 119 community-dwelling participants. Path analysis showed that direct (but not extended) contact with mental illness, by reducing intergroup anxiety, led to less negative beliefs about mental illness and weaker essentialist beliefs about mental illness (the latter being directly and positively associated with negative beliefs about mental illness). Moreover, less negative beliefs about mental illness, by reducing perceptions of self (but not public) stigma of seeking psychological help, were related to more positive attitudes towards help-seeking. Results are discussed in the context of the (unintentional) adverse effects of biogenetic (essentialist) explanations of mental disorders, and the clinical implications regarding interventions that aim at improving help-seeking attitudes.

  5. Can extra-articular strains be used to measure facet contact forces in the lumbar spine? An in-vitro biomechanical study.

    PubMed

    Zhu, Q A; Park, Y B; Sjovold, S G; Niosi, C A; Wilson, D C; Cripton, P A; Oxland, T R

    2008-02-01

    Experimental measurement of the load-bearing patterns of the facet joints in the lumbar spine remains a challenge, thereby limiting the assessment of facet joint function under various surgical conditions and the validation of computational models. The extra-articular strain (EAS) technique, a non-invasive measurement of the contact load, has been used for unilateral facet joints but does not incorporate strain coupling, i.e. ipsilateral EASs due to forces on the contralateral facet joint. The objectives of the present study were to establish a bilateral model for facet contact force measurement using the EAS technique and to determine its effectiveness in measuring these facet joint contact forces during three-dimensional flexibility tests in the lumbar spine. Specific goals were to assess the accuracy and repeatability of the technique and to assess the effect of soft-tissue artefacts. In the accuracy and repeatability tests, ten uniaxial strain gauges were bonded to the external surface of the inferior facets of L3 of ten fresh lumbar spine specimens. Two pressure-sensitive sensors (Tekscan) were inserted into the joints after the capsules were cut. Facet contact forces were measured with the EAS and Tekscan techniques for each specimen in flexion, extension, axial rotation, and lateral bending under a +/- 7.5 N m pure moment. Four of the ten specimens were tested five times in axial rotation and extension for repeatability. These same specimens were disarticulated and known forces were applied across the facet joint using a manual probe (direct accuracy) and a materials-testing system (disarticulated accuracy). In soft-tissue artefact tests, a separate set of six lumbar spine specimens was used to document the virtual facet joint contact forces during a flexibility test following removal of the superior facet processes. Linear strain coupling was observed in all specimens. The average peak facet joint contact forces during flexibility testing was greatest in axial rotation (71 +/- 25 N), followed by extension (27 +/- 35 N) and lateral bending (25 +/- 28 N), and they were most repeatable in axial rotation (coefficient of variation, 5 per cent). The EAS accuracy was about 20 per cent in the direct accuracy assessment and about 30 per cent in the disarticulated accuracy test. The latter was very similar to the Tekscan accuracy in the same test. Virtual facet loads (r.m.s.) were small in axial rotation (12 N) and lateral bending (20 N), but relatively large in flexion (34 N) and extension (35 N). The results suggested that the bilateral EAS model could be used to determine the facet joint contact forces in axial rotation but may result in considerable error in flexion, extension, and lateral bending.

  6. Antimicrobial activity of the essential oils of Thymus vulgaris L. measured using a bioimpedometric method.

    PubMed

    Marino, M; Bersani, C; Comi, G

    1999-09-01

    The essential oils obtained from Thymus vulgaris L. harvested at four ontogenetic stages were evaluated for their biological activity and chemical composition. The thyme essential oils were tested for their inhibitory effects against nine strains of gram-negative bacteria and six strains of gram-positive bacteria. The bioimpedance method was chosen for studying the antibacterial activity of the essential oils and the parameter chosen for defining and quantifying the antibacterial activity of the essential oils was the detection time. The plate counting technique was used to study the inhibitory effect by direct contact. All the thyme essential oils examined had a significant bacteriostatic activity against the microorganisms tested. This activity was more marked against the gram-positive bacteria. The oil from thyme in full flower was the most effective at stopping the growth of the microbial species examined. The oils tested were also shown to have good antibacterial activity by direct contact, which appeared to be more marked against the gram-negative bacteria. Only a few of the species were capable of recovering at least 50% of their metabolic function after contact with the inhibitor, while most of the strains were shown to have been inactivated almost completely. Escherichia coli O157:H7 was the most sensitive species, given that after contact with even the lowest concentration of oil cells could not be recovered.

  7. FreeContact: fast and free software for protein contact prediction from residue co-evolution.

    PubMed

    Kaján, László; Hopf, Thomas A; Kalaš, Matúš; Marks, Debora S; Rost, Burkhard

    2014-03-26

    20 years of improved technology and growing sequences now renders residue-residue contact constraints in large protein families through correlated mutations accurate enough to drive de novo predictions of protein three-dimensional structure. The method EVfold broke new ground using mean-field Direct Coupling Analysis (EVfold-mfDCA); the method PSICOV applied a related concept by estimating a sparse inverse covariance matrix. Both methods (EVfold-mfDCA and PSICOV) are publicly available, but both require too much CPU time for interactive applications. On top, EVfold-mfDCA depends on proprietary software. Here, we present FreeContact, a fast, open source implementation of EVfold-mfDCA and PSICOV. On a test set of 140 proteins, FreeContact was almost eight times faster than PSICOV without decreasing prediction performance. The EVfold-mfDCA implementation of FreeContact was over 220 times faster than PSICOV with negligible performance decrease. EVfold-mfDCA was unavailable for testing due to its dependency on proprietary software. FreeContact is implemented as the free C++ library "libfreecontact", complete with command line tool "freecontact", as well as Perl and Python modules. All components are available as Debian packages. FreeContact supports the BioXSD format for interoperability. FreeContact provides the opportunity to compute reliable contact predictions in any environment (desktop or cloud).

  8. Nickel on the Swedish market: follow-up 10 years after entry into force of the EU Nickel Directive.

    PubMed

    Biesterbos, Jacqueline; Yazar, Kerem; Lidén, Carola

    2010-12-01

    The EU Nickel Directive, aimed at primary and secondary prevention of nickel allergy by limitation of nickel release from certain items, came fully into force in July 2001. To assess the prevalence on the market of items with nickel release and to compare the outcome with previous studies performed in Sweden in 1999 and 2002-2003. Nickel release from 659 items covered by the EU Nickel Directive was assessed with the dimethylglyoxime (DMG) test. Special attention, as compared with the previous surveys, was given to cheap jewellery in street markets and sewing materials in haberdashery shops. Nickel release was shown for 9% of the tested items, all of which were intended for direct and prolonged contact with the skin. A high proportion of items bought at haberdashery shops and street markets, 34% and 61%, respectively, showed nickel release. The Swedish market for products intended for direct and prolonged contact with the skin has largely adapted to the Nickel Directive. It is suggested that authorities should monitor the market regularly and give attention to areas where compliance with the requirements is poor, for protection of public health. © 2010 John Wiley & Sons A/S.

  9. Biocompatibility and light transmission of liposomal lenses.

    PubMed

    Danion, Anne; Doillon, Charles J; Giasson, Claude J; Djouahra, Saliha; Sauvageau, Patrick; Paradis, Renée; Vermette, Patrick

    2007-10-01

    To validate the biocompatibility and transmittance properties of contact lenses bearing intact liposomes. These liposomal lenses loaded with therapeutics can be used as ophthalmic drug delivery systems. The biocompatibility of soft contact lenses, coated with liposomes was evaluated through in vitro direct and indirect cytocompatibility assays on human corneal epithelial cells, on reconstructed human corneas and on ex vivo rabbit corneas. The direct and indirect transmission spectra of liposome-covered lenses were also evaluated to test if they transmit all wavelengths of the ultraviolet-visible spectrum, to thereby fulfill their optical function, without gross alteration of the colors perception and with a minimum of light dispersion. Contact lenses bearing layers of stable liposomes did not induce any significant changes in cell viability and in cell growth, compared with lenses bearing no liposome. Elution assays revealed that no cytotoxic compound leaks from the lenses whether bearing liposomes or not. Histological analyses of reconstructed human corneas and ex vivo rabbit corneas directly exposed to liposomal lenses revealed neither alteration to the cell nor to the tissue structures. Contact lenses bearing layers of liposomes did not significantly affect light transmission compared with control lenses without liposome at the wavelength of maximal photopic sensitivity, i.e., 550 nm. In addition, the contact lenses afford more eye protection in the ultraviolet spectrum, compared with the control lenses. Liposomal contact lenses are biocompatible and their transmittance properties are not affected in the visible light range.

  10. Shear test on viscoelastic granular material using Contact Dynamics simulations

    NASA Astrophysics Data System (ADS)

    Quezada, Juan Carlos; Sagnol, Loba; Chazallon, Cyrille

    2017-06-01

    By means of 3D contact dynamic simulations, the behavior of a viscoelastic granular material under shear loading is investigated. A viscoelastic fluid phase surrounding the solid particles is simulated by a contact model acting between them. This contact law was implemented in the LMGC90 software, based on the Burgers model. This model is able to simulate also the effect of creep relaxation. To validate the proposed contact model, several direct shear tests were performed, experimentally and numerically using the Leutner device. The numerical samples were created using spheres with two particle size distribution, each one identified for two layers from a road structure. Our results show a reasonable agreement between experimental and numerical data regarding the strain-stress evolution curves and the stress levels measured at failure. The proposed model can be used to simulate the mechanical behavior of multi-layer road structure and to study the influence of traffic on road deformation, cracking and particles pull-out induced by traffic loading.

  11. Effect of Yttrium on the Microstructure and Properties of Pt-Ir Electrical Contact Materials

    NASA Astrophysics Data System (ADS)

    Wang, Saibei; Sun, Yong; Wang, Song; Peng, Mingjun; Liu, Manmen; Duan, Yonghua; Chen, Yongtai; Yang, Youcai; Chen, Song; Li, Aikun; Xie, Ming

    2017-10-01

    The Pt-10Ir and Pt-10Ir-1Y were prepared by high frequency induction melting, then the samples were obtained by powder metallurgy, hot extrusion and drawing. The influence of Y addition on microstructure and electrical contact properties of Pt-10Ir alloy has been investigated by using optical microscopy, SEM, electronic balance and the contact material test system. The results show that the addition of Y leads to the micro-structural refinement and directional change of material transfer, but has almost no influence on erosion morphology.

  12. Characterization of micro-contact resistance between a gold nanocrystalline line and a tungsten electrode probe in interconnect fatigue testing

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ling, Xue; Wang, Yusheng; Li, Xide, E-mail: lixide@tsinghua.edu.cn

    An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects ofmore » the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li–Etsion–Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.« less

  13. An experimental analysis of the real contact area between an electrical contact and a glass plane

    NASA Astrophysics Data System (ADS)

    Down, Michael; Jiang, Liudi; McBride, John W.

    2013-06-01

    The exact contact between two rough surfaces is usually estimated using statistical mathematics and surface analysis before and after contact has occurred. To date the majority of real contact and loaded surfaces has been theoretical or by numerical analyses. A method of analysing real contact area under various loads, by utilizing a con-contact laser surface profiler, allows direct measurement of contact area and deformation in terms of contact force and plane displacement between two surfaces. A laser performs a scan through a transparent flat side supported in a fixed position above the base. A test contact, mounted atop a spring and force sensor, and a screw support which moves into contact with the transparent surface. This paper presents the analysis of real contact area of various surfaces under various loads. The surfaces analysed are a pair of Au coated hemispherical contacts, one is a used Au to Au coated multi-walled carbon nanotubes surface, from a MEMS relay application, the other a new contact surface of the same configuration.

  14. The antiviral action of common household disinfectants and antiseptics against murine hepatitis virus, a potential surrogate for SARS coronavirus.

    PubMed

    Dellanno, Christine; Vega, Quinn; Boesenberg, Diane

    2009-10-01

    The 2003 outbreak of severe acute respiratory syndrome (SARS) infected over 8000 people and killed 774. Transmission of SARS occurred through direct and indirect contact and large droplet nuclei. The World Health Organization recommended the use of household disinfectants, which have not been previously tested against SARS coronavirus (SARS-CoV), to disinfect potentially contaminated environmental surfaces. There is a need for a surrogate test system given the limited availability of the SARS-CoV for testing and biosafety requirements necessary to safely handle it. In this study, the antiviral activity of standard household products was assayed against murine hepatitis virus (MHV), as a potential surrogate for SARS-CoV. A surface test method, which involves drying an amount of virus on a surface and then applying the product for a specific contact time, was used to determine the virucidal activity. The virus titers and log reductions were determined by the Reed and Muench tissue culture infective dose (TCID)50 end point method. When tested as directed, common household disinfectants or antiseptics, containing either 0.050% of triclosan, 0.12% of PCMX, 0.21% of sodium hypochlorite, 0.23% of pine oil, or 0.10% of a quaternary compound with 79% of ethanol, demonstrated a 3-log reduction or better against MHV without any virus recovered in a 30-second contact time. Common household disinfectants and antiseptics were effective at inactivating MHV, a possible surrogate for SARS-CoV, from surfaces when used as directed. In an outbreak caused by novel agents, it is important to know the effectiveness of disinfectants and antiseptics to prevent or reduce the possibility of human-to-human transmission via surfaces.

  15. Solid-on-solid contact in a sphere-wall collision in a viscous fluid

    NASA Astrophysics Data System (ADS)

    Birwa, Sumit Kumar; Rajalakshmi, G.; Govindarajan, Rama; Menon, Narayanan

    2018-04-01

    We study experimentally the collision between a sphere falling through a viscous fluid and a solid plate below. It is known that there is a well-defined threshold Stokes number above which the sphere rebounds from such a collision. Our experiment tests for direct contact between the colliding bodies and, contrary to prior theoretical predictions, shows that solid-on-solid contact occurs even for Stokes numbers just above the threshold for rebounding. The dissipation is fluid dominated, though details of the contact mechanics depend on the surface and bulk properties of the solids. Our experiments and a model calculation indicate that mechanical contact between the two colliding objects is generic and will occur for any realistic surface roughness.

  16. What Are Bone Marrow Tests?

    MedlinePlus

    ... Learn more about getting to NIH Get Email Alerts Receive automatic alerts about NHLBI related news and ... Connect With Us Contact Us Directly Get Email Alerts Receive automatic alerts about NHLBI related news and ...

  17. 76 FR 16425 - Draft Guidance for Industry: Testing for Salmonella

    Federal Register 2010, 2011, 2012, 2013, 2014

    2011-03-23

    ... draft guidance does not apply to egg producers and other persons who are covered by FDA's final rule ``Prevention of Salmonella Enteritidis in Shell Eggs During Production, Storage, and Transportation.'' The... eggs) and direct-human-contact animal foods, and the interpretation of test results, when the presence...

  18. Evolution of the microstructure during the process of consolidation and bonding in soft granular solids.

    PubMed

    Yohannes, B; Gonzalez, M; Abebe, A; Sprockel, O; Nikfar, F; Kiang, S; Cuitiño, A M

    2016-04-30

    The evolution of microstructure during powder compaction process was investigated using a discrete particle modeling, which accounts for particle size distribution and material properties, such as plasticity, elasticity, and inter-particle bonding. The material properties were calibrated based on powder compaction experiments and validated based on tensile strength test experiments for lactose monohydrate and microcrystalline cellulose, which are commonly used excipient in pharmaceutical industry. The probability distribution function and the orientation of contact forces were used to study the evolution of the microstructure during the application of compaction pressure, unloading, and ejection of the compact from the die. The probability distribution function reveals that the compression contact forces increase as the compaction force increases (or the relative density increases), while the maximum value of the tensile contact forces remains the same. During unloading of the compaction pressure, the distribution approaches a normal distribution with a mean value of zero. As the contact forces evolve, the anisotropy of the powder bed also changes. Particularly, during loading, the compression contact forces are aligned along the direction of the compaction pressure, whereas the tensile contact forces are oriented perpendicular to direction of the compaction pressure. After ejection, the contact forces become isotropic. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics

    PubMed Central

    Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung

    2017-01-01

    Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses. PMID:28447604

  20. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics.

    PubMed

    Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung

    2017-04-27

    Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.

  1. Wearable smart sensor systems integrated on soft contact lenses for wireless ocular diagnostics

    NASA Astrophysics Data System (ADS)

    Kim, Joohee; Kim, Minji; Lee, Mi-Sun; Kim, Kukjoo; Ji, Sangyoon; Kim, Yun-Tae; Park, Jihun; Na, Kyungmin; Bae, Kwi-Hyun; Kyun Kim, Hong; Bien, Franklin; Young Lee, Chang; Park, Jang-Ung

    2017-04-01

    Wearable contact lenses which can monitor physiological parameters have attracted substantial interests due to the capability of direct detection of biomarkers contained in body fluids. However, previously reported contact lens sensors can only monitor a single analyte at a time. Furthermore, such ocular contact lenses generally obstruct the field of vision of the subject. Here, we developed a multifunctional contact lens sensor that alleviates some of these limitations since it was developed on an actual ocular contact lens. It was also designed to monitor glucose within tears, as well as intraocular pressure using the resistance and capacitance of the electronic device. Furthermore, in-vivo and in-vitro tests using a live rabbit and bovine eyeball demonstrated its reliable operation. Our developed contact lens sensor can measure the glucose level in tear fluid and intraocular pressure simultaneously but yet independently based on different electrical responses.

  2. Contact guidance is cell cycle-dependent.

    PubMed

    Pourfarhangi, Kamyar Esmaeili; De La Hoz, Edgar Cardenas; Cohen, Andrew R; Gligorijevic, Bojana

    2018-09-01

    Cancer cell migration is essential for metastasis, during which cancer cells move through the tumor and reach the blood vessels. In vivo , cancer cells are exposed to contact guidance and chemotactic cues. Depending on the strength of such cues, cells will migrate in a random or directed manner. While similar cues may also stimulate cell proliferation, it is not clear whether cell cycle progression affects migration of cancer cells and whether this effect is different in random versus directed migration. In this study, we tested the effect of cell cycle progression on contact guided migration in 2D and 3D environments, in the breast carcinoma cell line, FUCCI-MDA-MB-231. The results were quantified from live cell microscopy images using the open source lineage editing and validation image analysis tools (LEVER). In 2D, cells were placed inside 10 μ m-wide microchannels to stimulate contact guidance, with or without an additional chemotactic gradient of the soluble epidermal growth factor. In 3D, contact guidance was modeled by aligned collagen fibers. In both 2D and 3D, contact guidance was cell cycle-dependent, while the addition of the chemo-attractant gradient in 2D increased cell velocity and persistence in directionally migrating cells, regardless of their cell cycle phases. In both 2D and 3D contact guidance, cells in the G1 phase of the cell cycle outperformed cells in the S/G2 phase in terms of migration persistence and instantaneous velocity. These data suggest that in the presence of contact guidance cues in vivo , breast carcinoma cells in the G1 phase of the cell cycle may be more efficient in reaching the neighboring vasculature.

  3. Evaluation of Antibacterial Effects of Silver-Coated Stainless Steel Orthodontic Brackets.

    PubMed

    Arash, Valiollah; Keikhaee, Fatemeh; Rabiee, Sayed Mahmood; Rajabnia, Ramazan; Khafri, Soraya; Tavanafar, Saeid

    2016-01-01

    White spots and enamel demineralization around orthodontic brackets are among the most important complications resulting from orthodontic treatments. Since the antibacterial properties of metals and metallic particles have been well documented, the aim of this study was to assess the antibacterial effect of stainless steel orthodontic brackets coated with silver (Ag) particles. In this study, 40 standard metal brackets were divided into two groups of 20 cases and 20 controls. The brackets in the case group were coated with Ag particles using an electroplating method. Atomic force microscopy and scanning electron microscopy were used to assess the adequacy of the coating process. In addition, antibacterial tests, i.e., disk diffusion and direct contact tests were performed at three, six, 24, and 48 hours, and 15 and 30 days using a Streptococcus mutans strain. The results were analyzed using Student's t-test and repeated measures ANOVA. Analyses via SEM and AFM confirmed that excellent coatings were obtained by using an electroplating method. The groups exhibited similar behavior when subjected to the disk diffusion test in the agar medium. However, the bacterial counts of the Ag-coated brackets were, in general, significantly lower (P<0.001) than those of their non-coated counterparts. Brackets coated with Ag, via an electroplating method, exhibited antibacterial properties when placed in direct contact with Streptococcus mutans. This antibacterial effect persisted for 30 days after contact with the bacteria.

  4. Contact allergy to the 26 specific fragrance ingredients to be declared on cosmetic products in accordance with the EU cosmetics directive.

    PubMed

    Heisterberg, Maria V; Menné, Torkil; Johansen, Jeanne D

    2011-11-01

    Fragrance ingredients are a frequent cause of allergic contact dermatitis. The EU Cosmetics Directive states that 26 specific fragrance ingredients, known to cause allergic contact dermatitis, must be declared on the ingredient lists of cosmetic products. To investigate frequencies of sensitization to the 26 individual fragrances and evaluate their importance as screening markers of fragrance allergy. This was a retrospective study based on data from the Department of Dermato-Allergology, Copenhagen University Hospital Gentofte. Eczema patients (n = 1508) were patch tested (January 2008 to July 2010) with the 26 fragrance ingredients. Sensitization to the 26 fragrances was identified in 115 (7.6%) subjects. The most frequent allergens were Evernia furfuracea (n = 50), Evernia prunastri (n = 31), and hydroxyisohexyl 3-cyclohexene carboxaldehyde (n = 24). Including fragrance mix I, fragrance mix II and Myroxylon pereirae, 196 (13.0%) had a fragrance allergy. Testing with the 26 fragrances additionally identified 23 subjects who would otherwise have gone undetected. The majority (75.7%) of positive reactions to the 26 fragrances were of clinical relevance. Sensitization to the 26 individual fragrance ingredients was identified in 7.6% of the subjects patch tested. Most reactions were of clinical relevance. Fragrance-allergic subjects would be missed if testing with the individual fragrance ingredients was not performed. © 2011 John Wiley & Sons A/S.

  5. Impedance hand controllers for increasing efficiency in teleoperations

    NASA Technical Reports Server (NTRS)

    Carignan, C.; Tarrant, J.

    1989-01-01

    An impedance hand controller with direct force feedback is examined as an alternative to bilateral force reflection in teleoperations involving force contact. Experimentation revealed an operator preference for direct force feedback which provided a better feel of contact with the environment. The advantages of variable arm impedance were also made clear in tracking tests where subjects preferred the larger hand controller inertias made possible by the acceleration feedback loop in the master arm. The ability to decouple the hand controller impedance from the slave arm dynamics is expected to be even more significant when the inertial properties of various payloads in the slave arm are considered.

  6. Characterization of Thermal Stability and High-Temperature Tribological Behavior of Electroless Ni-B Coating

    NASA Astrophysics Data System (ADS)

    Pal, Soupitak; Sarkar, Rohit; Jayaram, Vikram

    2018-05-01

    A preliminary study has been conducted using sequences of isothermal heat treatments and unidirectional high-temperature wear test following ball-on-flat geometry against an alumina counterface, to assess thermal stability and high-temperature tribological properties of the crystalline electroless Ni-B coating, a potential candidate for high-temperature solid lubricant coating. Isothermal heat treatment of 450 °C/15 h causes a significant amount of B diffusion into the Fe substrate without altering the coating's through-thickness hardness and nanostructure. At room temperature, a very low wear rate is observed, which increases up to two orders of magnitude above a testing temperature of 100 °C. Room-temperature wear behavior is mostly governed by oxidative wear, where friction-induced heating produces a thick oxide scale on the wear track, which subsequently decreases the wear rate by preventing direct contact between the coating and counterface. In the case of wear tests above 100 °C, removal of the same oxide layer occurs through local plastic deformation, essentially plastic ratcheting at the contacting region by flow softening of the contacting surface layer due to a local rise in temperature. Worn track morphology shows similarity with the severe wear seen in steel-steel contacts. Experimental observations have been explained and validated using the concept of contact point flash temperature. A quantitative assessment of contact point flash temperature has been carried out adopting the methodology, proposed by Ashby et al. The effects of applied normal load, test geometry, choice of counterface material, and testing temperatures on the transition of wear mechanism are critically discussed.

  7. The development of European standard (CEN) methods in support of European Directives for plastics materials and articles intended to come into contact with foodstuff.

    PubMed

    Ashby, R

    1994-01-01

    CEC Directives have been implemented for plastics materials and articles intended to come into contact with foodstuffs. These introduce limits upon the overall migration from plastics into food and food simulants. In addition, specific migration limits or composition limits for free monomer in the final article, have been set for some monomers. Agreed test methods are required to allow these Directives to be respected. CEN, the European Committee for Standardization, has created a working group to develop suitable test methods. This is 'Working Group 5, Chemical Methods of Test', of CEN Technical Committee TC 194, Utensils in contact with food. This group has drafted a ten part standard for determining overall migration into aqueous and fatty food simulants by total immersion, by standard cell, by standard pouch and by filling. This draft standard has been approved by CEN TC 194 for circulation for public comment as a provisional standard, i.e. as an ENV. Further parts of this standard are in preparation for determining overall migration at high temperatures, etc. Simultaneously, Working Group 5 is cooperating with the BCR (Community Bureau of Reference) to produce reference materials with certified values of overall migration. CEN TC 194 Working Group 5 is also drafting methods for monomers subject to limitation in Directive 90/128/EEC. Good progress is being made on the monomers of highest priority but it is recognized that developing methods for all the monomers subject to limitation would take many years. Therefore, collaboration with the BCR, the Council of Europe and others is taking place to accelerate method development.

  8. Incorporating contact angles in the surface tension force with the ACES interface curvature scheme

    NASA Astrophysics Data System (ADS)

    Owkes, Mark

    2017-11-01

    In simulations of gas-liquid flows interacting with solid boundaries, the contact line dynamics effect the interface motion and flow field through the surface tension force. The surface tension force is directly proportional to the interface curvature and the problem of accurately imposing a contact angle must be incorporated into the interface curvature calculation. Many commonly used algorithms to compute interface curvatures (e.g., height function method) require extrapolating the interface, with defined contact angle, into the solid to allow for the calculation of a curvature near a wall. Extrapolating can be an ill-posed problem, especially in three-dimensions or when multiple contact lines are near each other. We have developed an accurate methodology to compute interface curvatures that allows for contact angles to be easily incorporated while avoiding extrapolation and the associated challenges. The method, known as Adjustable Curvature Evaluation Scale (ACES), leverages a least squares fit of a polynomial to points computed on the volume-of-fluid (VOF) representation of the gas-liquid interface. The method is tested by simulating canonical test cases and then applied to simulate the injection and motion of water droplets in a channel (relevant to PEM fuel cells).

  9. Disproportionate Minority Contact.

    PubMed

    Fix, Rebecca L; Cyperski, Melissa A; Burkhart, Barry R

    2017-04-01

    The overrepresentation of racial/ethnic minorities within the criminal justice system relative to their population percentage, a phenomenon termed disproportionate minority contact, has been examined within general adult and adolescent offender populations; yet few studies have tested whether this phenomenon extends to juvenile sexual offenders (JSOs). In addition, few studies have examined whether offender race/ethnicity influences registration and notification requirements, which JSOs are subject to in some U.S. states. The present study assessed for disproportionate minority contact among general delinquent offenders and JSOs, meaning it aimed to test whether the criminal justice system treats those accused of sexual and non-sexual offenses differently by racial/ethnic group. Furthermore, racial/ethnic group differences in risk, legal classification, and sexual offending were examined for JSOs. Results indicated disproportionate minority contact was present among juveniles with non-sexual offenses and JSOs in Alabama. In addition, offense category and risk scores differed between African American and European American JSOs. Finally, registration classifications were predicted by offending characteristics, but not race/ethnicity. Implications and future directions regarding disproportionate minority contact among JSOs and social and legal policy affecting JSOs are discussed.

  10. Implementation of non-condensable gases condensation suppression model into the WCOBRA/TRAC-TF2 LOCA safety evaluation code

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Liao, J.; Cao, L.; Ohkawa, K.

    2012-07-01

    The non-condensable gases condensation suppression model is important for a realistic LOCA safety analysis code. A condensation suppression model for direct contact condensation was previously developed by Westinghouse using first principles. The model is believed to be an accurate description of the direct contact condensation process in the presence of non-condensable gases. The Westinghouse condensation suppression model is further revised by applying a more physical model. The revised condensation suppression model is thus implemented into the WCOBRA/TRAC-TF2 LOCA safety evaluation code for both 3-D module (COBRA-TF) and 1-D module (TRAC-PF1). Parametric study using the revised Westinghouse condensation suppression model ismore » conducted. Additionally, the performance of non-condensable gases condensation suppression model is examined in the ACHILLES (ISP-25) separate effects test and LOFT L2-5 (ISP-13) integral effects test. (authors)« less

  11. Silver-free Metallization Technology for Producing High Efficiency, Industrial Silicon Solar Cells

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Michaelson, Lynne M.; Munoz, Krystal; Karas, Joseph

    The goal of this project is to provide a commercially viable Ag-free metallization technology that will both reduce cost and increase efficiency of standard silicon solar cells. By removing silver from the front grid metallization and replacing it with lower cost nickel, copper, and tin metal, the front grid direct materials costs will decrease. This reduction in material costs should provide a path to meeting the Sunshot 2020 goal of 1 dollar / W DC. As of today, plated contacts are not widely implemented in large scale manufacturing. For organizations that wish to implement pilot scale manufacturing, only two equipmentmore » choices exist. These equipment manufacturers do not supply plating chemistry. The main goal of this project is to provide a chemistry and equipment solution to the industry that enables reliable manufacturing of plated contacts marked by passing reliability results and higher efficiencies than silver paste front grid contacts. To date, there have been several key findings that point to plated contacts performing equal to or better than the current state of the art silver paste contacts. Poor adhesion and reliability concerns are a few of the hurdles for plated contacts, specifically plated nickel directly on silicon. A key finding of the Phase 1 budget period is that the plated contacts have the same adhesion as the silver paste controls. This is a huge win for plated contacts. With very little optimization work, state of the art electrical results for plated contacts on laser ablated lines have been demonstrated with efficiencies up to 19.1% and fill factors ~80% on grid lines 40-50 um wide. The silver paste controls with similar line widths demonstrate similar electrical results. By optimizing the emitter and grid design for the plated contacts, it is expected that the electrical performance will exceed the silver paste controls. In addition, cells plated using Technic chemistry and equipment pass reliability testing; i.e. 1000 hours damp heat and 200 thermal cycles, with results similar to silver paste control cells. 100 cells have been processed through Technic’s novel demo plating tool built and installed during budget period 2. This plating tool performed consistently from cell to cell, providing gentle handling for the solar cells. An agreement has been signed with a cell manufacturer to process their cells through our plating chemistry and equipment. Their main focus for plated contacts is to reduce the direct materials cost by utilizing nickel, copper, and tin in place of silver paste. Based on current market conditions and cost model calculations, the overall savings offered by plated contacts is only 3.5% dollar/W versus silver paste contacts; however, the direct materials savings depend on the silver market. If silver prices increase, plated contacts may find a wider adoption in the solar industry in order to keep the direct materials costs down for front grid contacts.« less

  12. Genetics, Receptor Binding, Replication, and Mammalian Transmission of H4 Avian Influenza Viruses Isolated from Live Poultry Markets in China

    PubMed Central

    Liang, Libin; Deng, Guohua; Shi, Jianzhong; Wang, Shuai; Zhang, Qianyi; Kong, Huihui; Gu, Chunyang; Guan, Yuntao; Suzuki, Yasuo; Li, Yanbing; Jiang, Yongping; Tian, Guobin; Liu, Liling

    2015-01-01

    ABSTRACT H4 avian influenza virus (AIV) is one of the most prevalent influenza virus subtypes in the world. However, whether H4 AIVs pose a threat to public health remains largely unclear. Here, we analyzed the phylogenetic relationships, receptor binding properties, replication, and transmissibility in mammals of H4 AIVs isolated from live poultry markets in China between 2009 and 2012. Genomic sequence analysis of 36 representative H4 viruses revealed 32 different genotypes, indicating that these viruses are undergoing complex and frequent reassortment events. All 32 viruses tested could replicate in the respiratory organs of infected mice without prior adaptation. Receptor binding analysis demonstrated that the H4 AIVs bound to α-2,6-linked glycans, although they retained the binding preference for α-2,3-linked glycans. When we tested the direct-contact transmission of 10 H4 viruses in guinea pigs, we found that three viruses did not transmit to any of the contact animals, one virus transmitted to one of three contact animals, and six viruses transmitted to all three contact animals. When we further tested the respiratory droplet transmissibility of four of the viruses that transmitted efficiently via direct contact, we found that three of them could transmit to one or two of the five exposed animals. Our study demonstrates that the current circulating H4 AIVs can infect, replicate in, and transmit to mammalian hosts, thereby posing a potential threat to human health. These findings emphasize the continual need for enhanced surveillance of H4 AIVs. IMPORTANCE Numerous surveillance studies have documented the wide distribution of H4 AIVs throughout the world, yet the biological properties of H4 viruses have not been well studied. In this study, we found that multiple genotypes of H4 viruses are cocirculating in the live poultry markets of China and that H4 viruses can replicate in mice, possess human-type receptor binding specificity, and transmit between guinea pigs via direct contact. Strikingly, some H4 strains also can transmit via respiratory droplet, albeit with limited efficiency. These results clearly show the potential threat posed by H4 viruses to public health. PMID:26581996

  13. Elastic-plastic cube model for ultrasonic friction reduction via Poisson's effect.

    PubMed

    Dong, Sheng; Dapino, Marcelo J

    2014-01-01

    Ultrasonic friction reduction has been studied experimentally and theoretically. This paper presents a new elastic-plastic cube model which can be applied to various ultrasonic lubrication cases. A cube is used to represent all the contacting asperities of two surfaces. Friction force is considered as the product of the tangential contact stiffness and the deformation of the cube. Ultrasonic vibrations are projected onto three orthogonal directions, separately changing contact parameters and deformations. Hence, the overall change of friction forces. Experiments are conducted to examine ultrasonic friction reduction using different materials under normal loads that vary from 40 N to 240 N. Ultrasonic vibrations are generated both in longitudinal and vertical (out-of-plane) directions by way of the Poisson effect. The tests show up to 60% friction reduction; model simulations describe the trends observed experimentally. Copyright © 2013 Elsevier B.V. All rights reserved.

  14. Genotypic characteristics of Mycobacterium tuberculosis isolated from household contacts of tuberculosis patients in the Philippines.

    PubMed

    Sia, Irene G; Buckwalter, Seanne P; Doerr, Kelly A; Lugos, Sonia; Kramer, Rebecca; Orillaza-Chi, Ruth; Quelapio, Maria Imelda; Tupasi, Thelma E; Wengenack, Nancy L

    2013-12-05

    The Philippines has an extremely high rate of tuberculosis but little is known about M. tuberculosis genotypes and transmission dynamics in this country. The aim of this study was to determine the proportion of household contacts who develop active TB due to direct transmission from an index case in that household. Mycobacterium tuberculosis isolates from household contacts of tuberculosis patients in the Philippines were characterized using restriction-fragment-length polymorphism analysis, spoligotyping, and mycobacterial interspersed repetitive units - variable number tandem repeats typing (12-loci) to determine their utility in elucidating transmission in an area of high tuberculosis prevalence. Drug susceptibility patterns for these isolates were also determined. Spoligotyping and MIRU-VNTR typing results matched in 10 (62.5%) of 16 index patient-household contact pairs while IS6110 fingerprints matched in only six (37.5%) pairs. Only 3/16 (18.8%) index patient-household contact pairs had identical drug susceptibility results. Strain typing of M. tuberculosis isolates from household contacts in the Philippines indicates that transmission of strains does not necessarily occur directly from the index patient living in close proximity in the same household but rather that community-based transmission also frequently occurs. Accurate susceptibility testing of all isolates is necessary to insure optimal care of both the index patients and any culture-positive household contacts.

  15. Rate and State Friction Relation for Nanoscale Contacts: Thermally Activated Prandtl-Tomlinson Model with Chemical Aging

    NASA Astrophysics Data System (ADS)

    Tian, Kaiwen; Goldsby, David L.; Carpick, Robert W.

    2018-05-01

    Rate and state friction (RSF) laws are widely used empirical relationships that describe macroscale to microscale frictional behavior. They entail a linear combination of the direct effect (the increase of friction with sliding velocity due to the reduced influence of thermal excitations) and the evolution effect (the change in friction with changes in contact "state," such as the real contact area or the degree of interfacial chemical bonds). Recent atomic force microscope (AFM) experiments and simulations found that nanoscale single-asperity amorphous silica-silica contacts exhibit logarithmic aging (increasing friction with time) over several decades of contact time, due to the formation of interfacial chemical bonds. Here we establish a physically based RSF relation for such contacts by combining the thermally activated Prandtl-Tomlinson (PTT) model with an evolution effect based on the physics of chemical aging. This thermally activated Prandtl-Tomlinson model with chemical aging (PTTCA), like the PTT model, uses the loading point velocity for describing the direct effect, not the tip velocity (as in conventional RSF laws). Also, in the PTTCA model, the combination of the evolution and direct effects may be nonlinear. We present AFM data consistent with the PTTCA model whereby in aging tests, for a given hold time, static friction increases with the logarithm of the loading point velocity. Kinetic friction also increases with the logarithm of the loading point velocity at sufficiently high velocities, but at a different increasing rate. The discrepancy between the rates of increase of static and kinetic friction with velocity arises from the fact that appreciable aging during static contact changes the energy landscape. Our approach extends the PTT model, originally used for crystalline substrates, to amorphous materials. It also establishes how conventional RSF laws can be modified for nanoscale single-asperity contacts to provide a physically based friction relation for nanoscale contacts that exhibit chemical bond-induced aging, as well as other aging mechanisms with similar physical characteristics.

  16. Preliminary metallographic studies of ball fatigue under rolling-contact conditions

    NASA Technical Reports Server (NTRS)

    Bear, H Robert; Butler, Robert H

    1957-01-01

    The metallurgical results produced on balls tested in the rolling-contact fatigue spin rig were studied by metallographic examination. Origin and progression of fatigue failures were observed. These evaluations were made on SAE 52100 and AISI M-1 balls fatigue tested at room temperature (80 F) and 200 to 250 F. Most failures originated subsurface in shear; inclusions, structure changes, and directionalism adversely affected ball fatigue life. Structures in the maximum-shear-stress region of the balls of both materials were stable at room temperature and unstable at 200 to 250 F. Failures were of the same type as those found in full-scale bearings.

  17. Nasally-Administered Oxytocin Has Limited Effects on Owner-Directed Attachment Behavior in Pet Dogs (Canis lupus familiaris)

    PubMed Central

    Thielke, Lauren E.; Rosenlicht, Giovanna; Saturn, Sarina R.; Udell, Monique A. R.

    2017-01-01

    The present study explored the effects of intranasal oxytocin, a naturally occurring hormone, on the behavior of pet dogs during an attachment test. Each dog participated in two testing sessions. On one visit saline was administered nasally, and on another, oxytocin was administered nasally. For half of the dogs (n = 20), solutions were administered with a Mucosal Atomization Device (MAD) and for half of the dogs (n = 20), solutions were administered using a nasal spray bottle. Condition order was counterbalanced and a double-blind methodology was employed. Following a 30-min wait period after administration of solutions, dog-owner pairs participated in the Secure Base Test, a short attachment test consisting of three 2-min phases: (1) Baseline- the owner was present, dogs were able to freely explore the testing room (2) Alone- dogs were left alone in the testing room (3) Return- owners re-entered the room and were reunited with their dog. In each phase the dog was evaluated for contact seeking, exploration, and avoidance behaviors. Although, oxytocin administration was expected to increase owner-directed proximity and contact seeking behavior, this effect was not observed. In fact, in the baseline phase, dogs spent significantly more time seeking the proximity of their owners when they received saline than when they received OT (p < 0.05). Sex differences were also assessed for the behavioral variables of interest in the Secure Base Test, and results indicated that OT did not affect dogs' behavior in the alone phase, but when saline was administered, females spent significantly more time in contact with the door than males in the alone phase (p < 0.05). Overall, the effects of nasally administered oxytocin on attachment related behavior appeared to be limited or inconsistent for this pet dog population. PMID:29033879

  18. [Eye contact in adult patients with Asperger syndrome].

    PubMed

    Roy, M; Wolfgang, D

    2015-05-01

    It is unclear if individuals with autism spectrum disorders rarely hold direct eye contact because eyes are unimportant for them, or if it is actively avoided. The aim of the current investigation was to gain a better understanding for their views on direct eye contact by exploring adult patients with Asperger syndrome. 63 adult patients with Asperger syndrome (28 females, 35 males, 21 - 62 years old) were explored about using and sensing direct eye contact by means of a standardised questionnaire. 87 % of investigated patients depict direct eye contact as being disagreeable. They describe it as arduous and distracting. Therefore they mostly actively avoid direct eye contact. The here gained knowledge about aversion towards direct eye contact in individuals with autism should lead to a stronger understanding and acceptance of this problem in the non-autistic population. © Georg Thieme Verlag KG Stuttgart · New York.

  19. Direct current testing to measure corrosiveness of wood preservatives

    Treesearch

    Samuel L. Zelinka; Douglas R. Rammer; Donald S. Stone; James T. Gilbertson

    2007-01-01

    A qualitative test that mimics the corrosion behaviour of metals in contact with treated wood without using wood specimens would be of great value in rapidly evaluating the corrosiveness of new wood preservatives. The objective of this study was to determine whether the linear polarisation resistance of metals immersed in a solution of preservative chemicals is related...

  20. Direct soil contact values for ecological receptors exposed to weathered petroleum hydrocarbon (PHC) fraction 2.

    PubMed

    Angell, Robin A; Kullman, Steve; Shrive, Emma; Stephenson, Gladys L; Tindal, Miles

    2012-11-01

    Ecological tier 1 Canada-wide standards (CWS) for petroleum hydrocarbon (PHC) fraction 2 (F2; >nC10-C16) in soil were derived using ecotoxicological assessment endpoints (effective concentrations [ECs]/lethal concentrations [LCs]/inhibitory concentrations, 25% [IC25s]) with freshly spiked (fresh) fine- and coarse-grained soils. These soil standards might be needlessly conservative when applied to field samples with weathered hydrocarbons. The purpose of the present study was to assess the degradation and toxicity of weathered PHC F2 in a fine-grained soil and to derive direct soil contact values for ecological receptors. Fine-grained reference soils were spiked with distilled F2 and weathered for 183 d. Toxicity tests using plants and invertebrates were conducted with the weathered F2-spiked soils. Endpoint EC/IC25s were calculated and used to derive soil standards for weathered F2 in fine-grained soil protective of ecological receptors exposed via direct soil contact. The values derived for weathered F2 were less restrictive than current ecological tier 1 CWS for F2 in soil. Copyright © 2012 SETAC.

  1. Evaluation of Antibacterial Effects of Silver-Coated Stainless Steel Orthodontic Brackets

    PubMed Central

    Arash, Valiollah; Keikhaee, Fatemeh; Rajabnia, Ramazan; Khafri, Soraya; Tavanafar, Saeid

    2016-01-01

    Objectives: White spots and enamel demineralization around orthodontic brackets are among the most important complications resulting from orthodontic treatments. Since the antibacterial properties of metals and metallic particles have been well documented, the aim of this study was to assess the antibacterial effect of stainless steel orthodontic brackets coated with silver (Ag) particles. Materials and Methods: In this study, 40 standard metal brackets were divided into two groups of 20 cases and 20 controls. The brackets in the case group were coated with Ag particles using an electroplating method. Atomic force microscopy and scanning electron microscopy were used to assess the adequacy of the coating process. In addition, antibacterial tests, i.e., disk diffusion and direct contact tests were performed at three, six, 24, and 48 hours, and 15 and 30 days using a Streptococcus mutans strain. The results were analyzed using Student’s t-test and repeated measures ANOVA. Results: Analyses via SEM and AFM confirmed that excellent coatings were obtained by using an electroplating method. The groups exhibited similar behavior when subjected to the disk diffusion test in the agar medium. However, the bacterial counts of the Ag-coated brackets were, in general, significantly lower (P<0.001) than those of their non-coated counterparts. Conclusions: Brackets coated with Ag, via an electroplating method, exhibited antibacterial properties when placed in direct contact with Streptococcus mutans. This antibacterial effect persisted for 30 days after contact with the bacteria. PMID:27536328

  2. Comparison between FEBio and Abaqus for biphasic contact problems.

    PubMed

    Meng, Qingen; Jin, Zhongmin; Fisher, John; Wilcox, Ruth

    2013-09-01

    Articular cartilage plays an important role in the function of diarthrodial joints. Computational methods have been used to study the biphasic mechanics of cartilage, and Abaqus has been one of the most widely used commercial software packages for this purpose. A newly developed open-source finite element solver, FEBio, has been developed specifically for biomechanical applications. The aim of this study was to undertake a direct comparison between FEBio and Abaqus for some practical contact problems involving cartilage. Three model types, representing a porous flat-ended indentation test, a spherical-ended indentation test, and a conceptual natural joint contact model, were compared. In addition, a parameter sensitivity study was also performed for the spherical-ended indentation test to investigate the effects of changes in the input material properties on the model outputs, using both FEBio and Abaqus. Excellent agreement was found between FEBio and Abaqus for all of the model types and across the range of material properties that were investigated.

  3. Comparison between FEBio and Abaqus for biphasic contact problems

    PubMed Central

    Jin, Zhongmin; Fisher, John; Wilcox, Ruth

    2013-01-01

    Articular cartilage plays an important role in the function of diarthrodial joints. Computational methods have been used to study the biphasic mechanics of cartilage, and Abaqus has been one of the most widely used commercial software packages for this purpose. A newly developed open-source finite element solver, FEBio, has been developed specifically for biomechanical applications. The aim of this study was to undertake a direct comparison between FEBio and Abaqus for some practical contact problems involving cartilage. Three model types, representing a porous flat-ended indentation test, a spherical-ended indentation test, and a conceptual natural joint contact model, were compared. In addition, a parameter sensitivity study was also performed for the spherical-ended indentation test to investigate the effects of changes in the input material properties on the model outputs, using both FEBio and Abaqus. Excellent agreement was found between FEBio and Abaqus for all of the model types and across the range of material properties that were investigated. PMID:23804955

  4. Imaging graphite in air by scanning tunneling microscopy - Role of the tip

    NASA Technical Reports Server (NTRS)

    Colton, R. J.; Baker, S. M.; Driscoll, R. J.; Youngquist, M. G.; Baldeschwieler, J. D.; Kaiser, W. J.

    1988-01-01

    Atomically resolved images of highly oriented pyrolytic graphite (HOPG) in air at point contact have been obtained. Direct contact between tip and sample or contact through a contamination layer provides a conduction mechanism in addition to the exponential tunneling mechanism responsible for scanning tunneling microscopy (STM) imaging. Current-voltage (I-V) spectra were obtained while scanning in the current imaging mode with the feedback circuit interrupted in order to study the graphite imaging mechanism. Multiple tunneling tips are probably responsible for images without the expected hexagonal or trigonal symmetry. The observations indicate that the use of HOPG for testing and calibration of STM instrumentation may be misleading.

  5. Evaluating the impact of direct and indirect contact on the mental health stigma of pharmacy students.

    PubMed

    Nguyen, Elizabeth; Chen, Timothy F; O'Reilly, Claire L

    2012-07-01

    Contact with mental health consumers has shown to be a promising strategy to address mental health stigma, particularly in the context of pharmacy education. This research aimed to compare the effectiveness of a direct (face-to-face) contact intervention with an indirect (film based) contact intervention in reducing the mental health stigma of pharmacy students. A two-group, non-randomized, comparative study was conducted with third year pharmacy students (n = 198) allocated to the direct contact arm and fourth year pharmacy students (n = 278) allocated to the indirect contact arm. Baseline and immediate post-intervention data were collected using a validated 39 item survey instrument to assess the impact of the interventions on mental health stigma as well as attitudes towards providing mental health pharmaceutical services. Participants in the direct contact group showed a significant improvement in 37 out of 39 survey items and participants in the indirect contact group showed a significant improvement in 27 out of 39 items (P < 0.05). While direct contact had a stronger impact than indirect contact for 22 items (P < 0.05), for numerous key measures of mental health stigma the impact of the two contact interventions was equivalent. Both indirect and direct contact may positively impact mental health stigma. While the strength of the stigma-change process may be heightened by face-to-face interactions, the largely positive impact of indirect contact suggests that stigma reduction may depend less on the medium of contact but more on the transcendent messages contributed by the consumers facilitating the contact experience.

  6. Intranasal oxytocin and a polymorphism in the oxytocin receptor gene are associated with human-directed social behavior in golden retriever dogs.

    PubMed

    Persson, Mia E; Trottier, Agaia J; Bélteky, Johan; Roth, Lina S V; Jensen, Per

    2017-09-01

    The oxytocin system may play an important role in dog domestication from the wolf. Dogs have evolved unique human analogue social skills enabling them to communicate and cooperate efficiently with people. Genomic differences in the region surrounding the oxytocin receptor (OXTR) gene have previously been associated with variation in dogs' communicative skills. Here we have utilized the unsolvable problem paradigm to investigate the effects of oxytocin and OXTR polymorphisms on human-directed contact seeking behavior in 60 golden retriever dogs. Human-oriented behavior was quantified employing a previously defined unsolvable problem paradigm. Behaviors were tested twice in a repeated, counterbalanced design, where dogs received a nasal dose of either oxytocin or saline 45min before each test occasion. Buccal DNA was analysed for genotype on three previously identified SNP-markers associated with OXTR. The same polymorphisms were also genotyped in 21 wolf blood samples to explore potential genomic differences between the species. Results showed that oxytocin treatment decreased physical contact seeking with the experimenter and one of the three polymorphisms was associated with degree of physical contact seeking with the owner. Dogs with the AA-genotype at this locus increased owner physical contact seeking in response to oxytocin while the opposite effect was found in GG-genotype individuals. Hence, intranasal oxytocin treatment, an OXTR polymorphism and their interaction are associated with dogs' human-directed social skills, which can explain previously described breed differences in oxytocin response. Genotypic variation at the studied locus was also found in wolves indicating that it was present even at the start of dog domestication. Copyright © 2017 Elsevier Inc. All rights reserved.

  7. Composition, diffusion, and antifungal activity of black mustard (Brassica nigra) essential oil when applied by direct addition or vapor phase contact.

    PubMed

    Mejía-Garibay, Beatriz; Palou, Enrique; López-Malo, Aurelio

    2015-04-01

    In this study, we characterized the essential oil (EO) of black mustard (Brassica nigra) and quantified its antimicrobial activity, when applied by direct contact into the liquid medium or by exposure in the vapor phase (in laboratory media or in a bread-type product), against the growth of Aspergillus niger, Aspergillus ochraceus, or Penicillium citrinum. Allyl-isothiocyanate (AITC) was identified as the major component of B. nigra EO with a concentration of 378.35 mg/ml. When B. nigra EO was applied by direct contact into the liquid medium, it inhibited the growth of A. ochraceus and P. citrinum when the concentration was 2 μl/ml of liquid medium (MIC), while for A. niger, a MIC of B. nigra EO was 4 μl/ml of liquid medium. Exposure of molds to B. nigra EO in vapor phase showed that 41.1 μl of B. nigra EO per liter of air delayed the growth of P. citrinum and A. niger by 10 days, while A. ochraceus growth was delayed for 20 days. Exposure to concentrations ≥ 47 μl of B. nigra EO per liter of air (MIC) inhibited the growth of tested molds by 30 days, and they were not able to recover after further incubation into an environment free of EO (fungicidal effect). Adsorbed AITC was quantified by exposing potato dextrose agar to B. nigra EO in a vapor phase, exhibiting that AITC was retained at least 5 days when testing EO at its MIC or with higher concentrations. Mustard EO MIC was also effective against the evaluated molds inhibiting their growth for 30 days in a bread-type product when exposed to EO by vapor contact, demonstrating its antifungal activity.

  8. 21 CFR 882.1570 - Powered direct-contact temperature measurement device.

    Code of Federal Regulations, 2012 CFR

    2012-04-01

    ... 21 Food and Drugs 8 2012-04-01 2012-04-01 false Powered direct-contact temperature measurement... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1570 Powered direct-contact temperature measurement device. (a) Identification. A powered direct...

  9. 21 CFR 882.1570 - Powered direct-contact temperature measurement device.

    Code of Federal Regulations, 2014 CFR

    2014-04-01

    ... 21 Food and Drugs 8 2014-04-01 2014-04-01 false Powered direct-contact temperature measurement... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1570 Powered direct-contact temperature measurement device. (a) Identification. A powered direct...

  10. 21 CFR 882.1570 - Powered direct-contact temperature measurement device.

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ... 21 Food and Drugs 8 2013-04-01 2013-04-01 false Powered direct-contact temperature measurement... HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882.1570 Powered direct-contact temperature measurement device. (a) Identification. A powered direct...

  11. Fabrication of bioinspired composite nanofiber membranes with robust superhydrophobicity for direct contact membrane distillation.

    PubMed

    Liao, Yuan; Wang, Rong; Fane, Anthony G

    2014-06-03

    The practical application of membrane distillation (MD) for water purification is hindered by the absence of desirable membranes that can fulfill the special requirements of the MD process. Compared to the membranes fabricated by other methods, nanofiber membranes produced by electrospinning are of great interest due to their high porosity, low tortuosity, large surface pore size, and high surface hydrophobicity. However, the stable performance of the nanofiber membranes in the MD process is still unsatisfactory. Inspired by the unique structure of the lotus leaf, this study aimed to develop a strategy to construct superhydrophobic composite nanofiber membranes with robust superhydrophobicity and high porosity suitable for use in MD. The newly developed membrane consists of a superhydrophobic silica-PVDF composite selective skin formed on a polyvinylidene fluoride (PVDF) porous nanofiber scaffold via electrospinning. This fabrication method could be easily scaled up due to its simple preparation procedures. The effects of silica diameter and concentration on membrane contact angle, sliding angle, and MD performance were investigated thoroughly. For the first time, the direct contact membrane distillation (DCMD) tests demonstrate that the newly developed membranes are able to present stable high performance over 50 h of testing time, and the superhydrophobic selective layer exhibits excellent durability in ultrasonic treatment and a continuous DCMD test. It is believed that this novel design strategy has great potential for MD membrane fabrication.

  12. Spatial cues serving the tactile directional sensibility of the human forearm.

    PubMed Central

    Norrsell, U; Olausson, H

    1994-01-01

    1. Tactile directional sensibility is considered to rely on the parallel processing of direction-contingent sensory data that depend on skin stretching caused by friction, and spatial cues that vary with time. A temperature-controlled airstream stimulus that prevented the activation of stretch receptors was used to investigate directional sensibility for the skin of the forearm. 2. The dependence on contact load and distance of movement was determined for normal subjects with a two-alternative forced-choice method. Testing was performed under two conditions, elbow bent or straight. Bracing the skin by straightening the arm did not alter the accuracy of the directional sensibility, in contrast to previous findings with stimuli that caused friction. 3. The accuracy of directional sensibility was correlated linearly to the logarithm of the distance of movement of the air jet. No correlation was found between accuracy and contact load, unlike findings with stimuli that cause friction. 4. Measurements were made with different subjects to determine the threshold distance at constant load. On average, subjects were able to distinguish direction with movements of < or = 8 mm. This acuity is sharper than has been reported with static stimuli. There was no correlation between subjects' threshold distances for judging direction and spatial acuity measured with absolute point localization. 5. The ability to distinguish direction was poor for the airstream stimulus compared with stimuli causing frictional contact with hairy skin. Nevertheless, the present findings are consistent with the suggestion that cutaneous spatial acuity is better for dynamic than for static stimuli. Images Figure 1 PMID:7965863

  13. Participant observation of time allocation, direct patient contact and simultaneous activities in hospital physicians.

    PubMed

    Weigl, Matthias; Müller, Andreas; Zupanc, Andrea; Angerer, Peter

    2009-06-29

    Hospital physicians' time is a critical resource in medical care. Two aspects are of interest. First, the time spent in direct patient contact - a key principle of effective medical care. Second, simultaneous task performance ('multitasking') which may contribute to medical error, impaired safety behaviour, and stress. There is a call for instruments to assess these aspects. A preliminary study to gain insight into activity patterns, time allocation and simultaneous activities of hospital physicians was carried out. Therefore an observation instrument for time-motion-studies in hospital settings was developed and tested. 35 participant observations of internists and surgeons of a German municipal 300-bed hospital were conducted. Complete day shifts of hospital physicians on wards, emergency ward, intensive care unit, and operating room were continuously observed. Assessed variables of interest were time allocation, share of direct patient contact, and simultaneous activities. Inter-rater agreement of Kappa = .71 points to good reliability of the instrument. Hospital physicians spent 25.5% of their time at work in direct contact with patients. Most time was allocated to documentation and conversation with colleagues and nursing staff. Physicians performed parallel simultaneous activities for 17-20% of their work time. Communication with patients, documentation, and conversation with colleagues and nursing staff were the most frequently observed simultaneous activities. Applying logit-linear analyses, specific primary activities increase the probability of particular simultaneous activities. Patient-related working time in hospitals is limited. The potential detrimental effects of frequently observed simultaneous activities on performance outcomes need further consideration.

  14. Abnormal tibiofemoral contact stress and its association with altered kinematics after center-center anterior cruciate ligament reconstruction: an in vitro study.

    PubMed

    Imhauser, Carl; Mauro, Craig; Choi, Daniel; Rosenberg, Eric; Mathew, Stephen; Nguyen, Joseph; Ma, Yan; Wickiewicz, Thomas

    2013-04-01

    Abnormal tibiofemoral contact stress and aberrant kinematics may influence the progression of osteoarthritis in the anterior cruciate ligament (ACL)-deficient and the ACL-reconstructed knee. However, relationships between contact stress and kinematics after ACL reconstruction are poorly understood. Therefore, we posed the following research questions: (1) How do ACL deficiency and reconstruction affect the kinematics of and contact stress in the tibiofemoral joint? (2) What kinematic differences are associated with abnormal contact stress after ACL reconstruction? Center-center ACL reconstruction will not restore knee kinematics and contact stress. Correlations will exist between abnormal contact stress and aberrant kinematics after ACL reconstruction. Controlled laboratory study. Clinical tests of anterior and rotational stability were simulated on 11 cadaveric knees using an industrial robot. Tests were conducted with the ACL intact, sectioned, and after single-bundle ACL reconstruction using a quadrupled hamstring autograft with tunnels drilled through the center of the native footprints. Kinematics were recorded during the tests. Contact stress was continuously recorded from a stress transducer fixed to the tibial plateau, and mean contact stress was calculated regionally. ACL deficiency resulted in increased mean contact stress in the posterior sectors of the medial and lateral compartments under anterior and rotational loads, respectively. Reconstruction reduced stress in these locations; however, contact stress abnormalities remained. On average, kinematics were overconstrained after ACL reconstruction (≤1.8 mm and ≤2.6° in all directions). However, combinations of overconstrained and underconstrained motions in abduction/adduction and medial-lateral translation in response to combined moments, and anterior-posterior translation, medial-lateral translation, and axial rotation in response to an anterior load were associated with abnormal mean contact stress. ACL reconstruction reduces high stresses generated in the posterior compartment of the ACL-deficient knee. Abnormal contact stress after ACL reconstruction is related to multiplanar variations in knee kinematics. Clinical measures of multiplanar kinematics may help to better characterize the quality of ACL reconstruction. Such measures may help identify patients at increased risk of long-term joint degeneration following this surgery.

  15. Abnormal tibiofemoral contact stress and its association with altered kinematics following center-center ACL reconstruction: an in vitro study

    PubMed Central

    Imhauser, Carl; Mauro, Craig; Choi, Daniel; Rosenberg, Eric; Mathew, Stephen; Nguyen, Joseph; Ma, Yan; Wickiewicz, Thomas

    2014-01-01

    Background Abnormal tibiofemoral contact stress and aberrant kinematics may influence the progression of osteoarthritis in the ACL-deficient and the ACL-reconstructed knee. However, relationships between contact stress and kinematics following ACL reconstruction are poorly understood. Therefore, we posed the following research questions: (1) How do ACL deficiency and reconstruction affect kinematics of and contact stress in the tibiofemoral joint? (2) What kinematic differences are associated with abnormal contact stress following ACL reconstruction? Hypothesis/Purpose Center-center ACL reconstruction will not restore knee kinematics and contact stress. Correlations will exist between abnormal contact stress and aberrant kinematics following ACL reconstruction will exist. Study Design Controlled laboratory study Methods Clinical tests of anterior and rotational stability were simulated on eleven cadaveric knees using an industrial robot. Tests were conducted with the ACL intact, sectioned, and after single bundle ACL reconstruction using a quadrupled hamstring autograft with tunnels drilled through the center of the native footprints. Kinematics were recorded during the tests. Contact stress was continuously recorded from a stress transducer fixed to the tibial plateau and mean contact stress was calculated regionally. Results ACL deficiency resulted in increased mean contact stress in the posterior sectors of the medial and lateral compartments under anterior and rotational loads, respectively. Reconstruction reduced stress in these locations; however contact stress abnormalities remained. On average, kinematics were overconstrained following ACL reconstruction (≤1.8mm and ≤2.6° in all directions). However, combinations of overconstrained and underconstrained motions in ab/adduction and medial-lateral translation in response to combined moments, and axial rotation, anterior-posterior and medial-lateral translation in response to an anterior load were associated with abnormal mean contact stress. Conclusions ACL reconstruction reduces high stresses generated in the posterior compartment of the ACL-deficient knee. Abnormal contact stress following ACL reconstruction is related to multiplanar variations in knee kinematics. Clinical Relevance Clinical measures of multiplanar kinematics may help to better characterize the quality of ACL reconstruction. Such measures may help identify those at increased risk of long-term joint degeneration following this surgery. PMID:23470858

  16. Fabrication of High Contact-Density, Flat-Interface Nerve Electrodes for Recording and Stimulation Applications.

    PubMed

    Dweiri, Yazan M; Stone, Matthew A; Tyler, Dustin J; McCallum, Grant A; Durand, Dominique M

    2016-10-04

    Many attempts have been made to manufacture multi-contact nerve cuff electrodes that are safe, robust and reliable for long term neuroprosthetic applications. This protocol describes a fabrication technique of a modified cylindrical nerve cuff electrode to meet these criteria. Minimum computer-aided design and manufacturing (CAD and CAM) skills are necessary to consistently produce cuffs with high precision (contact placement 0.51 ± 0.04 mm) and various cuff sizes. The precision in spatially distributing the contacts and the ability to retain a predefined geometry accomplished with this design are two criteria essential to optimize the cuff's interface for selective recording and stimulation. The presented design also maximizes the flexibility in the longitudinal direction while maintaining sufficient rigidity in the transverse direction to reshape the nerve by using materials with different elasticities. The expansion of the cuff's cross sectional area as a result of increasing the pressure inside the cuff was observed to be 25% at 67 mm Hg. This test demonstrates the flexibility of the cuff and its response to nerve swelling post-implant. The stability of the contacts' interface and recording quality were also examined with contacts' impedance and signal-to-noise ratio metrics from a chronically implanted cuff (7.5 months), and observed to be 2.55 ± 0.25 kΩ and 5.10 ± 0.81 dB respectively.

  17. Viral contacts confound studies of childhood leukemia and high-voltage transmission lines.

    PubMed

    Sahl, J D

    1994-05-01

    Studies of childhood leukemia have reported a link with residential proximity to electric utility facilities. This paper elaborates on the hypothesis that residential proximity to electric utility transmission-systems is a surrogate for viral contacts, a potential confounder in these studies. While the causal implications of increased viral contacts is not established, the assumption made here is that a significant component of childhood leukemia has an infectious etiology. Increased viral contacts can result from residential mobility, being first born, or use of community childcare facilities. Re-analysis of existing studies should look specifically for the interaction between childhood leukemia, markers for viral contacts (e.g., residential mobility, birth order, use of outside childcare facilities), and residential proximity to high-voltage transmission lines. New study designs should include parameters to test directly for a virus-related infectious model for childhood leukemia.

  18. The Extended Contact Hypothesis: A Meta-Analysis on 20 Years of Research.

    PubMed

    Zhou, Shelly; Page-Gould, Elizabeth; Aron, Arthur; Moyer, Anne; Hewstone, Miles

    2018-04-01

    According to the extended contact hypothesis, knowing that in-group members have cross-group friends improves attitudes toward this out-group. This meta-analysis covers the 20 years of research that currently exists on the extended contact hypothesis, and consists of 248 effect sizes from 115 studies. The aggregate relationship between extended contact and intergroup attitudes was r = .25, 95% confidence interval (CI) = [.22, .27], which reduced to r = .17, 95% CI = [.14, .19] after removing direct friendship's contribution; these results suggest that extended contact's hypothesized relationship to intergroup attitudes is small-to-medium and exists independently of direct friendship. This relationship was larger when extended contact was perceived versus actual, highlighting the importance of perception in extended contact. Current results on extended contact mostly resembled their direct friendship counterparts, suggesting similarity between these contact types. These unique insights about extended contact and its relationship with direct friendship should enrich and spur growth within this literature.

  19. Preference for social contact versus environmental enrichment in male laboratory mice.

    PubMed

    Van Loo, P L P; Van de Weerd, H A; Van Zutphen, L F M; Baumans, V

    2004-04-01

    Due to their aggressive nature, male mice are less frequently used than female mice in biomedical research. When aggressive males are being used, individual housing is common practice. The question arises whether this is an acceptable housing for a social species. The present study was designed to gain more insight into the nature of inter-male social contact and into the potential of a form of environmental enrichment (nesting material) to compensate for the lack of social contact. In a series of tests, we analysed whether male mice of different ages preferred to spend time (1) near a familiar cage mate versus an empty cage, or (2) near to a familiar cage mate versus direct contact with nesting material (tissues). Dwelling time in each of the test cages and sleeping sites was recorded, as was the behaviour of the test mice. Results indicated that when other conditions were similar, male mice preferred to sleep in close proximity to their familiar cage mate. Furthermore, the need to engage in active social behaviour increased with age. Tissues were used to a large extent for sleeping and sleep-related behaviour. It is concluded that single housing in order to avoid aggression between male mice is a solution with evident negative consequences for the animals. When individual housing is inevitable due to excessive aggressive behaviour, the presence of nesting material could partly compensate for the deprivation of social contact.

  20. Three degree-of-freedom force feedback control for robotic mating of umbilical lines

    NASA Technical Reports Server (NTRS)

    Fullmer, R. Rees

    1988-01-01

    The use of robotic manipulators for the mating and demating of umbilical fuel lines to the Space Shuttle Vehicle prior to launch is investigated. Force feedback control is necessary to minimize the contact forces which develop during mating. The objective is to develop and demonstrate a working robotic force control system. Initial experimental force control tests with an ASEA IRB-90 industrial robot using the system's Adaptive Control capabilities indicated that control stability would by a primary problem. An investigation of the ASEA system showed a 0.280 second software delay between force input commands and the output of command voltages to the servo system. This computational delay was identified as the primary cause of the instability. Tests on a second path into the ASEA's control computer using the MicroVax II supervisory computer show that time delay would be comparable, offering no stability improvement. An alternative approach was developed where the digital control system of the robot was disconnected and an analog electronic force controller was used to control the robot's servosystem directly, allowing the robot to use force feedback control while in rigid contact with a moving three-degree-of-freedom target. An alternative approach was developed where the digital control system of the robot was disconnected and an analog electronic force controller was used to control the robot's servo system directly. This method allowed the robot to use force feedback control while in rigid contact with moving three degree-of-freedom target. Tests on this approach indicated adequate force feedback control even under worst case conditions. A strategy to digitally-controlled vision system was developed. This requires switching between the digital controller when using vision control and the analog controller when using force control, depending on whether or not the mating plates are in contact.

  1. Is Contact with Children Related to Legitimizing Beliefs Toward Sex with Children Among Men with Pedophilia?

    PubMed

    Geradt, Max; Jahnke, Sara; Heinz, Julia; Hoyer, Jürgen

    2018-02-01

    Among pedophilic men, social contact with children has been discussed as creating a risk situation for sexual abuse. Also, pedophilic men searching for such contact are seen as harboring more beliefs legitimizing sexual contact with children. However, social contact may also decrease false beliefs. We tested these competing views in an anonymous Internet survey with a non-forensic, non-clinical sample of 104 self-classified pedophilic men. Results showed that both increased social and physical contact were significantly linked to fewer legitimizing beliefs toward sex with children, even when controlling for past psychotherapy, educational level, social desirability, and age. Controlling for previous conviction for child sexual offenses reduced the effect for physical contact, but not for social contact. Exploratory analyses showed that either type of contact had no significant effect on total self-perceived risk of offending. However, pedophilic men with physical contact with children perceived a higher risk of more direct (i.e., child abuse) than indirect offenses (i.e., child pornography offenses) compared to pedophilic men without physical contact. Despite limitations of the correlational design and the only small to moderate effects, the results challenge the assumption that complete avoidance of contact with children is necessary for persons with pedophilia to reduce the risk of abusive behavior.

  2. Influence of direct or indirect contact for the cytotoxicity and blood compatibility of spider silk.

    PubMed

    Kuhbier, J W; Coger, V; Mueller, J; Liebsch, C; Schlottmann, F; Bucan, V; Vogt, P M; Strauss, S

    2017-08-01

    Spider silk became one of the most-researched biomaterials in the last years due to its unique mechanical strength and most favourable chemical composition for tissue engineering purposes. However, standardized analysis of cytocompatibility is missing. Therefore, the aim of this study was to investigate hemolysis, cytotoxicity of native spider silk as well as influences on the cell culture medium. Changes of cell culture medium composition, osmolarity as well as glucose and lactate content were determined via ELISA measurement. Possible hemolysis and cytotoxicity in vitro of spider silk were performed via measurement of hemoglobin release of human red blood cells or relative metabolic activity of L929 fibroblasts, respectively, according to international standard procedures. In ELISA measurement, no significant changes in medium composition could be found in this study. Spider silk was not hemolytic in direct and indirect testing. However, a borderline cytotoxicity according to definitions was found in indirect cytotoxicity testing. Nevertheless, in direct cytotoxicity testing, relative metabolic activity measurement revealed that spider silk is not cytotoxic under these conditions. This is the first study to conduct standardized tests regarding cytotoxicity and hemolysis of native spider silk, which might be considered inert in cell culture. As neither hemolysis nor cytotoxicity was found in direct contact in standardized procedures, safety in biomedical applications may be assumed. The indirect cytotoxicity seems to play a minor role in vivo. However, a borderline toxicity was revealed, suggesting potential leachables not yet identified. Displays one of the weaving frames used in this study after seeding with the single drop technique described herein.

  3. Controlling direct contact force for wet adhesion with different wedged film stabilities

    NASA Astrophysics Data System (ADS)

    Li, Meng; Xie, Jun; Shi, Liping; Huang, Wei; Wang, Xiaolei

    2018-04-01

    In solid–liquid–solid adhesive systems, wedged films often feature instability at microscopic thicknesses, which can easily disrupt the adhesive strength of their remarkable direct contact force. Here, sodium dodecyl sulfate (SDS) was employed to tune the instability of adhesion in wedged glass–water–rubber films, achieving controllable direct contact. Experimental results showed that the supplement of SDS molecules significantly weakened the direct contact force for wet adhesion and eliminated it at high concentrations. The underlying reason was suggested to be the repulsive double-layer force caused by SDS molecules, which lowers the instability of the wedged film and balances the preload, disrupting the direct contact in wet adhesion.

  4. Renewable Water: Direct Contact Membrane Distillation Coupled With Solar Ponds

    NASA Astrophysics Data System (ADS)

    Suarez, F. I.; Tyler, S. W.; Childress, A. E.

    2010-12-01

    The exponential population growth and the accelerated increase in the standard of living have increased significantly the global consumption of two precious resources: water and energy. These resources are intrinsically linked and are required to allow a high quality of human life. With sufficient energy, water may be harvested from aquifers, treated for potable reuse, or desalinated from brackish and seawater supplies. Even though the costs of desalination have declined significantly, traditional desalination systems still require large quantities of energy, typically from fossil fuels that will not allow these systems to produce water in a sustainable way. Recent advances in direct contact membrane distillation can take advantage of low-quality or renewable heat to desalinate brackish water, seawater or wastewater. Direct contact membrane distillation operates at low pressures and can use small temperature differences between the feed and permeate water to achieve a significant freshwater production. Therefore, a much broader selection of energy sources can be considered to drive thermal desalination. A promising method for providing renewable source of heat for direct contact membrane distillation is a solar pond, which is an artificially stratified water body that captures solar radiation and stores it as thermal energy at the bottom of the pond. In this work, a direct contact membrane distillation/solar pond coupled system is modeled and tested using a laboratory-scale system. Freshwater production rates on the order of 2 L day-1 per m2 of solar pond (1 L hr-1 per m2 of membrane area) can easily be achieved with minimal operating costs and under low pressures. While these rates are modest, they are six times larger than those produced by other solar pond-powered desalination systems - and they are likely to be increased if heat losses in the laboratory-scale system are reduced. Even more, this system operates at much lower costs than traditional desalination systems, thus, it can be used to meet the future needs of energy and water use in a sustainable way.

  5. The chemical constitution and biocompatibility of accelerated Portland cement for endodontic use.

    PubMed

    Camilleri, J; Montesin, F E; Di Silvio, L; Pitt Ford, T R

    2005-11-01

    To evaluate the biocompatibility of mineral trioxide aggregate and accelerated Portland cement and their eluants by assessing cell metabolic function and proliferation. The chemical constitution of grey and white Portland cement, grey and white mineral trioxide aggregate (MTA) and accelerated Portland cement produced by excluding gypsum from the manufacturing process (Aalborg White) was determined using both energy dispersive analysis with X-ray and X-ray diffraction analysis. Biocompatibility of the materials was assessed using a direct test method where cell proliferation was measured quantitatively using Alamar Blue dye and an indirect test method where cells were grown on material elutions and cell proliferation was assessed using methyltetrazolium assay as recommended by the International standard guidelines, ISO 10993-Part 5 for in vitro testing. The chemical constitution of all the materials tested was similar. Indirect studies of the eluants showed an increase in cell activity after 24 h compared with the control in culture medium (P<0.05). Direct cell contact with the cements resulted in a fall in cell viability for all time points studied (P<0.001). Biocompatibility testing of the cement eluants showed the presence of no toxic leachables from the grey or white MTA, and that the addition of bismuth oxide to the accelerated Portland cement did not interfere with biocompatibility. The new accelerated Portland cement showed similar results. Cell growth was poor when seeded in direct contact with the test cements. However, the elution made up of calcium hydroxide produced during the hydration reaction was shown to induce cell proliferation.

  6. Photo-stimulated low electron temperature high current diamond film field emission cathode

    DOEpatents

    Shurter,; Roger Philips, Devlin [Los Alamos, NM; David James, Moody [Santa Fe, NM; Nathan Andrew, Taccetti [Los Alamos, NM; Jose Martin, Russell [Santa Fe, NM; John, Steven [Los Alamos, NM

    2012-07-24

    An electron source includes a back contact surface having a means for attaching a power source to the back contact surface. The electron source also includes a layer comprising platinum in direct contact with the back contact surface, a composite layer of single-walled carbon nanotubes embedded in platinum in direct contact with the layer comprising platinum. The electron source also includes a nanocrystalline diamond layer in direct contact with the composite layer. The nanocrystalline diamond layer is doped with boron. A portion of the back contact surface is removed to reveal the underlying platinum. The electron source is contained in an evacuable container.

  7. Scale Model Test and Transient Analysis of Steam Injector Driven Passive Core Injection System for Innovative-Simplified Nuclear Power Plant

    NASA Astrophysics Data System (ADS)

    Ohmori, Shuichi; Narabayashi, Tadashi; Mori, Michitsugu

    A steam injector (SI) is a simple, compact and passive pump and also acts as a high-performance direct-contact compact heater. This provides SI with capability to serve also as a direct-contact feed-water heater that heats up feed-water by using extracted steam from turbine. Our technology development aims to significantly simplify equipment and reduce physical quantities by applying "high-efficiency SI", which are applicable to a wide range of operation regimes beyond the performance and applicable range of existing SIs and enables unprecedented multistage and parallel operation, to the low-pressure feed-water heaters and emergency core cooling system of nuclear power plants, as well as achieve high inherent safety to prevent severe accidents by keeping the core covered with water (a severe accident-free concept). This paper describes the results of the scale model test, and the transient analysis of SI-driven passive core injection system (PCIS).

  8. A novel method to study contact inhibition of locomotion using micropatterned substrates

    PubMed Central

    Scarpa, Elena; Roycroft, Alice; Theveneau, Eric; Terriac, Emmanuel; Piel, Matthieu; Mayor, Roberto

    2013-01-01

    Summary The concept of contact inhibition of locomotion (CIL) describes the ability of a cell to change the direction of its movement after contact with another cell. It has been shown to be responsible for physiological and developmental processes such as wound healing, macrophage dispersion and neural crest cell migration; whereas its loss facilitates cancer cell invasion and metastatic dissemination. Different assays have been developed to analyze CIL in tissue culture models. However, these methods have several caveats. Collisions happen at low frequency between freely migrating cells and the orientation of the cells at the time of contact is not predictable. Moreover, the computational analysis required by these assays is often complicated and it retains a certain degree of discretion. Here, we show that confinement of neural crest cell migration on a single dimension by using a micropatterned substrate allows standardized and predictable cell–cell collision. CIL can thus easily be quantified by direct measurement of simple cellular parameters such as the distance between nuclei after collision. We tested some of the signaling pathways previously identified as involved in CIL, such as small GTPases and non-canonical Wnt signaling, using this new method for CIL analysis. The restricted directionality of migration of cells in lines is a powerful strategy to obtain higher predictability and higher efficiency of the CIL response upon cell–cell collisions. PMID:24143276

  9. Guided ultrasonic wave beam skew in silicon wafers

    NASA Astrophysics Data System (ADS)

    Pizzolato, Marco; Masserey, Bernard; Robyr, Jean-Luc; Fromme, Paul

    2018-04-01

    In the photovoltaic industry, monocrystalline silicon wafers are employed for solar cells with high conversion efficiency. Micro-cracks induced by the cutting process in the thin wafers can lead to brittle wafer fracture. Guided ultrasonic waves would offer an efficient methodology for the in-process non-destructive testing of wafers to assess micro-crack density. The material anisotropy of the monocrystalline silicon leads to variations of the guided wave characteristics, depending on the propagation direction relative to the crystal orientation. Selective guided ultrasonic wave excitation was achieved using a contact piezoelectric transducer with custom-made wedges for the A0 and S0 Lamb wave modes and a transducer holder to achieve controlled contact pressure and orientation. The out-of-plane component of the guided wave propagation was measured using a non-contact laser interferometer. The phase slowness (velocity) of the two fundamental Lamb wave modes was measured experimentally for varying propagation directions relative to the crystal orientation and found to match theoretical predictions. Significant wave beam skew was observed experimentally, especially for the S0 mode, and investigated from 3D finite element simulations. Good agreement was found with the theoretical predictions based on nominal material properties of the silicon wafer. The important contribution of guided wave beam skewing effects for the non-destructive testing of silicon wafers was demonstrated.

  10. Advanced Nanoindentation Testing for Studying Strain-Rate Sensitivity and Activation Volume

    NASA Astrophysics Data System (ADS)

    Maier-Kiener, Verena; Durst, Karsten

    2017-11-01

    Nanoindentation became a versatile tool for testing local mechanical properties beyond hardness and modulus. By adapting standard nanoindentation test methods, simple protocols capable of probing thermally activated deformation processes can be accomplished. Abrupt strain-rate changes within one indentation allow determining the strain-rate dependency of hardness at various indentation depths. For probing lower strain-rates and excluding thermal drift influences, long-term creep experiments can be performed by using the dynamic contact stiffness for determining the true contact area. From both procedures hardness and strain-rate, and consequently strain-rate sensitivity and activation volume can be reliably deducted within one indentation, permitting information on the locally acting thermally activated deformation mechanism. This review will first discuss various testing protocols including possible challenges and improvements. Second, it will focus on different examples showing the direct influence of crystal structure and/or microstructure on the underlying deformation behavior in pure and highly alloyed material systems.

  11. Contact Thermocouple Methodology and Evaluation for Temperature Measurement in the Laboratory

    NASA Technical Reports Server (NTRS)

    Brewer, Ethan J.; Pawlik, Ralph J.; Krause, David L.

    2013-01-01

    Laboratory testing of advanced aerospace components very often requires highly accurate temperature measurement and control devices, as well as methods to precisely analyze and predict the performance of such components. Analysis of test articles depends on accurate measurements of temperature across the specimen. Where possible, this task is accomplished using many thermocouples welded directly to the test specimen, which can produce results with great precision. However, it is known that thermocouple spot welds can initiate deleterious cracks in some materials, prohibiting the use of welded thermocouples. Such is the case for the nickel-based superalloy MarM-247, which is used in the high temperature, high pressure heater heads for the Advanced Stirling Converter component of the Advanced Stirling Radioisotope Generator space power system. To overcome this limitation, a method was developed that uses small diameter contact thermocouples to measure the temperature of heater head test articles with the same level of accuracy as welded thermocouples. This paper includes a brief introduction and a background describing the circumstances that compelled the development of the contact thermocouple measurement method. Next, the paper describes studies performed on contact thermocouple readings to determine the accuracy of results. It continues on to describe in detail the developed measurement method and the evaluation of results produced. A further study that evaluates the performance of different measurement output devices is also described. Finally, a brief conclusion and summary of results is provided.

  12. Effects of Preprocessing on Multi-Direction Properties of Aluminum Alloy Cold-Spray Deposits

    NASA Astrophysics Data System (ADS)

    Rokni, M. R.; Nardi, A. T.; Champagne, V. K.; Nutt, S. R.

    2018-05-01

    The effects of powder preprocessing (degassing at 400 °C for 6 h) on microstructure and mechanical properties of 5056 aluminum deposits produced by high-pressure cold spray were investigated. To investigate directionality of the mechanical properties, microtensile coupons were excised from different directions of the deposit, i.e., longitudinal, short transverse, long transverse, and diagonal and then tested. The results were compared to properties of wrought 5056 and the coating deposited with as-received 5056 Al powder and correlated with the observed microstructures. Preprocessing softened the particles and eliminated the pores within them, resulting in more extensive and uniform deformation upon impact with the substrate and with underlying deposited material. Microstructural characterization and finite element simulation indicated that upon particle impact, the peripheral regions experienced more extensive deformation and higher temperatures than the central contact zone. This led to more recrystallization and stronger bonding at peripheral regions relative to the contact zone area and yielded superior properties in the longitudinal direction compared with the short transverse direction. Fractography revealed that crack propagation takes place along the particle-particle interfaces in the transverse directions (caused by insufficient bonding and recrystallization), whereas through the deposited particles, fracture is dominant in the longitudinal direction.

  13. Geysers advanced direct contact condenser research

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Henderson, J.; Bahning, T.; Bharathan, D.

    1997-12-31

    The first geothermal application of the Advanced Direct Contact Condenser (ADCC) technology developed by the National Renewable Energy Laboratory (NREL) is now operational and is being tested at The Geysers Power Plant Unit 11. This major research effort is being supported through the combined efforts of NREL, The Department of Energy (DOE), and Pacific Gas and Electric (PG&E). NREL and PG&E have entered into a Cooperative Research And Development Agreement (CRADA) for a project to improve the direct-contact condenser performance at The Geysers Power Plant. This project is the first geothermal adaptation of an advanced condenser design developed for themore » Ocean Thermal Energy Conversion (OTEC) systems. PG&E expects this technology to improve power plant performance and to help extend the life of the steam field by using steam more efficiently. In accordance with the CRADA, no money is transferred between the contracting parties. In this case the Department of Energy is funding NREL for their efforts in this project and PG&E is contributing funds in kind. Successful application of this technology at The Geysers will provide a basis for NREL to continue to develop this technology for other geothermal and fossil power plant systems.« less

  14. Informing disease models with temporal and spatial contact structure among GPS-collared individuals in wild populations.

    PubMed

    Williams, David M; Dechen Quinn, Amy C; Porter, William F

    2014-01-01

    Contacts between hosts are essential for transmission of many infectious agents. Understanding how contacts, and thus transmission rates, occur in space and time is critical to effectively responding to disease outbreaks in free-ranging animal populations. Contacts between animals in the wild are often difficult to observe or measure directly. Instead, one must infer contacts from metrics such as proximity in space and time. Our objective was to examine how contacts between white-tailed deer (Odocoileus virginianus) vary in space and among seasons. We used GPS movement data from 71 deer in central New York State to quantify potential direct contacts between deer and indirect overlap in space use across time and space. Daily probabilities of direct contact decreased from winter (0.05-0.14), to low levels post-parturition through summer (0.00-0.02), and increased during the rut to winter levels. The cumulative distribution for the spatial structure of direct and indirect contact probabilities around a hypothetical point of occurrence increased rapidly with distance for deer pairs separated by 1,000 m-7,000 m. Ninety-five percent of the probabilities of direct contact occurred among deer pairs within 8,500 m of one another, and 99% within 10,900 m. Probabilities of indirect contact accumulated across greater spatial extents: 95% at 11,900 m and 99% at 49,000 m. Contacts were spatially consistent across seasons, indicating that although contact rates differ seasonally, they occur proportionally across similar landscape extents. Distributions of contact probabilities across space can inform management decisions for assessing risk and allocating resources in response.

  15. Development of Cone Wedge Ring Expansion Test to Evaluate Mechanical Properties of Clad Tubing Structure

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Jy-An John

    To determine the hoop tensile properties of irradiated fuel cladding in a hot cell, a cone wedge ring expansion test method was developed. A four-piece wedge insert was designed with tapered angles matched to the cone shape of a loading piston. The ring specimen was expanded in the radial direction by the lateral expansion of the wedges under the downward movement of the piston. The advantages of the proposed method are that implementation of the test setup in a hot cell is simple and easy, and that it enables a direct strain measurement of the test specimen from the piston’smore » vertical displacement soon after the wedge-clad contact resistance is initiated.« less

  16. Direct and extended intergenerational contact and young people's attitudes towards older adults.

    PubMed

    Drury, Lisbeth; Hutchison, Paul; Abrams, Dominic

    2016-09-01

    Research suggests that positive intergenerational contact can improve young people's attitudes towards older adults. However, today's age-segregated society may not provide ample opportunities for positive contact between younger and older adults to occur on a regular basis. In three studies, we investigated whether the positive attitudinal outcomes associated with direct contact might also stem from a more indirect form of intergenerational relationship: extended contact. In Study 1 (N = 70), extended contact was associated with more positive attitudes towards older adults even when controlling for direct intergenerational contact (contact frequency and contact quality). In Study 2 (N = 110), the positive effects of direct and extended contact on young people's age-related attitudes were mediated by reductions in intergroup anxiety and ageing anxiety. The mediational effects of intergroup anxiety were replicated in Study 3 (N = 95) and ingroup norms additionally emerged as a mediator of the positive effects of extended contact on young people's attitudes towards older adults. Discussion focuses on the implications for strategies aimed at tackling ageism. ©2016 The Authors. British Journal of Social Psychology published by John Wiley & Sons Ltd on behalf of British Psychological Society.

  17. 78 FR 46543 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-01

    ... corrosion of certain THSAs, ballscrew integrity tests if necessary; and replacing any affected THSA with a.... We will post all comments we receive, without change, to http://www.regulations.gov , including any personal information you provide. We will also post a report summarizing each substantive verbal contact we...

  18. Development and testing of laser-induced breakdown spectroscopy for the Mars Rover Program : elemental analysis at stand-off distances

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cremers, D. A.; Wiens, R. C.; Arp, Z. A.

    2003-01-01

    One of the most Fundamental pieces of information about any planetary body is the elemental cornposition of its surface materials. The Viking Martian landers employed XRF (x-ray fluorescence) and the MER rovers are carrying APXS (alpha-proton x-ray spectrometer) instruments upgraded from that used on the Pathfinder rover to supply elemental composition information for soils and rocks for which direct contact is possible. These in-situ analyses require that the lander or rover be in contact with the sample

  19. Thermally-Conductive Metallic Coatings and Applications for Heat Removal on In-Space Cryogenic Vehicles

    NASA Technical Reports Server (NTRS)

    Ameen, Lauren; Hervol, David; Waters, Deborah

    2017-01-01

    For large in-space cryogenic upper stages, substantial axial heat removal from a forward skirt by vapor-based heat interception may not be achieved by simple attachment methods unless sufficient thermal conductance from the skirt to the cooling fluid can be achieved. Preferable methods would allow for the addition of the cooling system to existing structure with minimal impact on the structure. Otherwise, significant modification to the basic structural design andor novel and complex attachment mechanisms with high effective thermal conductance are likely to be required. The approach being pursued by evolvable Cryogenics (eCryo) is to increase the thermal performance of a relatively simple attachment system by applying metallic or other thermally conductive material coatings to the mating surface area of the fluid channel where it is attached the skirt wall. The expectation of candidate materials is that the dramatic increase in conductivity of pure metals at temperatures close to liquid hydrogen vapor temperature will compensate for the reduced actual contact area typical of mechanical joints. Basic contact conductance data at low temperatures for candidate interface materials is required to enable the test approach. A test rig was designed at NASA Glenn Research Center to provide thermal contact resistance testing between small sample coupons coated with conductive material via electron beam evaporation, a low-temperature option that will not affect physical properties of base materials. Average coating thicknesses were 10 k. The test fixture was designed to mount directly to a cryocooler cold head within a vacuum test chamber. The purpose of this test was to determine qualitative contact conductance between various test samples. Results from this effort will be implemented in a sub-scale vapor-based heat interception test, where the applicability for increased heat removal on large structural skirts will be considered.

  20. 37 CFR 10.33 - Direct contact with prospective clients.

    Code of Federal Regulations, 2012 CFR

    2012-07-01

    ... TRADEMARK OFFICE, DEPARTMENT OF COMMERCE REPRESENTATION OF OTHERS BEFORE THE PATENT AND TRADEMARK OFFICE Patent and Trademark Office Code of Professional Responsibility § 10.33 Direct contact with prospective... 37 Patents, Trademarks, and Copyrights 1 2012-07-01 2012-07-01 false Direct contact with...

  1. Extreme-value statistics reveal rare failure-critical defects in additive manufacturing

    DOE PAGES

    Boyce, Brad L.; Salzbrenner, Bradley C.; Rodelas, Jeffrey M.; ...

    2017-04-21

    Additive manufacturing enables the rapid, cost effective production of large populations of material test coupons such as tensile bars. By adopting streamlined test methods including ‘drop-in’ grips and non-contact extensometry, testing these large populations becomes more efficient. Unlike hardness tests, the tensile test provides a direct measure of yield strength, flow properties, and ductility, which can be directly incorporated into solid mechanics simulations. In the present work, over 1000 nominally identical tensile tests were used to explore the effect of process variability on the mechanical property distributions of a precipitation hardened stainless steel, 17-4PH, produced by a laser powder bedmore » fusion process, also known as direct metal laser sintering. With this large dataset, rare defects are revealed that affect only ~2% of the population, stemming from a single build lot of material. Lastly, the rare defects caused a substantial loss in ductility and were associated with an interconnected network of porosity.« less

  2. Parotid gland tumours: MR tractography to assess contact with the facial nerve.

    PubMed

    Attyé, Arnaud; Karkas, Alexandre; Troprès, Irène; Roustit, Matthieu; Kastler, Adrian; Bettega, Georges; Lamalle, Laurent; Renard, Félix; Righini, Christian; Krainik, Alexandre

    2016-07-01

    To assess the feasibility of intraparotid facial nerve (VIIn) tractographic reconstructions in estimating the presence of a contact between the VIIn and the tumour, in patients requiring surgical resection of parotid tumours. Patients underwent MR scans with VIIn tractography calculated with the constrained spherical deconvolution model. The parameters of the diffusion sequence were: b-value of 1000 s/mm(2); 32 directions; voxel size: 2 mm isotropic; scan time: 9'31'. The potential contacts between VIIn branches and tumours were estimated with different initial fractional anisotropy (iFA) cut-offs compared to surgical data. Surgeons were blinded to the tractography reconstructions and identified both nerves and contact with tumours using nerve stimulation and reference photographs. Twenty-six patients were included in this study and the mean patient age was 55.2 years. Surgical direct assessment of VIIn allowed identifying 0.1 as the iFA threshold with the best sensitivity to detect tumour contact. In all patients with successful VIIn identification by tractography, surgeons confirmed nerve courses as well as lesion location in parotid glands. Mean VIIn branch FA values were significantly lower in cases with tumour contact (t-test; p ≤ 0.01). This study showed the feasibility of intraparotid VIIn tractography to identify nerve contact with parotid tumours. • Diffusion imaging is an efficient method for highlighting the intraparotid VIIn. • Visualization of the VIIn may help to better manage patients before surgery. • We bring new insights to future trials for patients with VIIn dysfunction. • We aimed to provide radio-anatomical references for further studies.

  3. Open-MRI measures of cam intrusion for hips in an anterior impingement position relate to acetabular contact force.

    PubMed

    Buchan, Lawrence L; Zhang, Honglin; Konan, Sujith; Heaslip, Ingrid; Ratzlaff, Charles R; Wilson, David R

    2016-02-01

    Open MRI in functional positions has potential to directly and non-invasively assess cam femoroacetabular impingement (FAI). Our objective was to investigate whether open MRI can depict intrusion of the cam deformity into the intra-articular joint space, and whether intrusion is associated with elevated acetabular contact force. Cadaver hips (9 cam; 3 controls) were positioned in an anterior impingement posture and imaged using open MRI with multi-planar reformatting. The β-angle (describing clearance between the femoral neck and acetabulum) was measured around the entire circumference of the femoral neck. We defined a binary "MRI cam-intrusion sign" (positive if β < 0°). We then instrumented each hip with a piezoresistive sensor and conducted six repeated positioning trials, measuring acetabular contact force (F). We defined a binary "contact-force sign" (positive if F > 20N). Cam hips were more likely than controls to have both a positive MRI cam-intrusion sign (p = 0.0182, Fisher's exact test) and positive contact-force sign (p = 0.0083), which represents direct experimental evidence for cam intrusion. There was also a relationship between the MRI cam-intrusion sign and contact-force sign (p = 0.033), representing a link between imaging and mechanics. Our findings indicate that open MRI has significant potential for in vivo investigation of the cam FAI mechanism. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  4. Social Contact Enhances Bodily Self-Awareness.

    PubMed

    Hazem, Nesrine; Beaurenaut, Morgan; George, Nathalie; Conty, Laurence

    2018-03-08

    Human self-awareness is arguably the most important and revealing question of modern sciences. Converging theoretical perspectives link self-awareness and social abilities in human beings. In particular, mutual engagement during social interactions-or social contact-would boost self-awareness. Yet, empirical evidence for this effect is scarce. We recently showed that the perception of eye contact induces enhanced bodily self-awareness. Here, we aimed at extending these findings by testing the influence of social contact in auditory and tactile modalities, in order to demonstrate that social contact enhances bodily self-awareness irrespective of sensory modality. In a first experiment, participants were exposed to hearing their own first name (as compared to another unfamiliar name and noise). In a second experiment, human touch (as compared to brush touch and no-touch) was used as the social contact cue. In both experiments, participants demonstrated more accurate rating of their bodily reactions in response to emotional pictures following the social contact condition-a proxy of bodily self-awareness. Further analyses indicated that the effect of social contact was comparable across tactile, auditory and visual modalities. These results provide the first direct empirical evidence in support of the essential social nature of human self-awareness.

  5. Assessment of antibacterial properties of newer dentin bonding agents: An in vitro study.

    PubMed

    Sampath, Pavitra B; Hegde, Mithra N; Hegde, Priyadarshini

    2011-07-01

    To evaluate and compare the antibacterial activity of newer dentin bonding agents on Streptococcus mutans using the direct contact test. Streptococcus mutans was used as test organism and a direct contact test was performed. The dentin bonding agents to be tested were grouped as Group I, Clearfil Protect Bond, Group II, Adper Easy One, and Group III, Prime and Bond NT. For the direct contact test, three microtiter plates consisting of 96 wells each were taken (288 wells). These wells were divided into three groups of 96 wells; 16 wells of a microtiter plate were utilized, of which four were designated as 'A' wells (with the dentin bonding agent and bacterial suspension), another four as 'B' wells (without the dentin bonding agent, but with the bacterial suspension), another four as the 'C' wells (with the tested material, but without bacteria, which served as the negative control), and the remaining four as the 'D' wells (without the dentin bonding agent, which served as the positive control). Each group was treated with their respective bonding agents as per the manufactures instructions. Broth of 15 μL was then transferred from the A wells into an adjacent set of B wells containing fresh medium (215 μL). This resulted in two sets of four wells for each tested material containing an equal volume of liquid medium, so that bacterial growth was monitored both in the presence and in the absence of the tested material. The plate was placed for incubation at 37°C in the microplate reader and the optical density in each well was measured at 600 nm. The readings were taken at regular intervals. (Every 30 minutes for 16 hours). The Dentin bonding agents evaluated in this study showed different inhibitory effects. Clearfil Protect Bond and Prime and Bond NT were most effective, and Adper Easy One was least effective against Streptococcus mutans. The Dentin bonding agents evaluated in this study showed different inhibitory effects. Clearfil Protect Bond and Prime and Bond NT were most effective, and Adper Easy One was the least effective against Streptococcus mutans. Hence, the incorporation of antibacterial agents into the dentin bonding agents may become an essential factor in inhibiting residual bacteria in the cavity and secondary caries.

  6. Informing Disease Models with Temporal and Spatial Contact Structure among GPS-Collared Individuals in Wild Populations

    PubMed Central

    Williams, David M.; Dechen Quinn, Amy C.; Porter, William F.

    2014-01-01

    Contacts between hosts are essential for transmission of many infectious agents. Understanding how contacts, and thus transmission rates, occur in space and time is critical to effectively responding to disease outbreaks in free-ranging animal populations. Contacts between animals in the wild are often difficult to observe or measure directly. Instead, one must infer contacts from metrics such as proximity in space and time. Our objective was to examine how contacts between white-tailed deer (Odocoileus virginianus) vary in space and among seasons. We used GPS movement data from 71 deer in central New York State to quantify potential direct contacts between deer and indirect overlap in space use across time and space. Daily probabilities of direct contact decreased from winter (0.05–0.14), to low levels post-parturition through summer (0.00–0.02), and increased during the rut to winter levels. The cumulative distribution for the spatial structure of direct and indirect contact probabilities around a hypothetical point of occurrence increased rapidly with distance for deer pairs separated by 1,000 m – 7,000 m. Ninety-five percent of the probabilities of direct contact occurred among deer pairs within 8,500 m of one another, and 99% within 10,900 m. Probabilities of indirect contact accumulated across greater spatial extents: 95% at 11,900 m and 99% at 49,000 m. Contacts were spatially consistent across seasons, indicating that although contact rates differ seasonally, they occur proportionally across similar landscape extents. Distributions of contact probabilities across space can inform management decisions for assessing risk and allocating resources in response. PMID:24409293

  7. A new fiber-optic non-contact compact laser-ultrasound scanner for fast non-destructive testing and evaluation of aircraft composites

    PubMed Central

    Pelivanov, Ivan; Buma, Takashi; Xia, Jinjun; Wei, Chen-Wei; O'Donnell, Matthew

    2014-01-01

    Laser ultrasonic (LU) inspection represents an attractive, non-contact method to evaluate composite materials. Current non-contact systems, however, have relatively low sensitivity compared to contact piezoelectric detection. They are also difficult to adjust, very expensive, and strongly influenced by environmental noise. Here, we demonstrate that most of these drawbacks can be eliminated by combining a new generation of compact, inexpensive fiber lasers with new developments in fiber telecommunication optics and an optimally designed balanced probe scheme. In particular, a new type of a balanced fiber-optic Sagnac interferometer is presented as part of an all-optical LU pump-probe system for non-destructive testing and evaluation of aircraft composites. The performance of the LU system is demonstrated on a composite sample with known defects. Wide-band ultrasound probe signals are generated directly at the sample surface with a pulsed fiber laser delivering nanosecond laser pulses at a repetition rate up to 76 kHz rate with a pulse energy of 0.6 mJ. A balanced fiber-optic Sagnac interferometer is employed to detect pressure signals at the same point on the composite surface. A- and B-scans obtained with the Sagnac interferometer are compared to those made with a contact wide-band polyvinylidene fluoride transducer. PMID:24737921

  8. An observational study on the effects of aviation turbine fuel and lubricants on the skin of Indian Air Force ground crew in flying stations.

    PubMed

    Radhakrishnan, S; Chopra, Ajay; Mitra, Debdeep; Gnanasekaran, R; Kanagaraj, R

    2017-07-01

    Ground crew of the Air Force routinely handle aviation turbine fuel (ATF) and lubricants and a need was felt to study the adverse effects of these substances on their skin so that remedial measures could be taken to prevent these adverse effects. A multi-centric, cross-sectional, observational study was performed at three Air Force flying stations. 109 ground crew members of the Indian Air Force (IAF) who were in direct contact with ATF and lubricants were screened for dermatological manifestations on exposed areas. History of atopy was elicited, systemic and dermatological examination done and occlusive patch testing carried out where indicated. Fungal infections were excluded by a potassium hydroxide mount. 20 out of the 109 personnel (18.34%) were symptomatic in the form of mild irritant contact dermatitis. There was no case of allergic contact dermatitis. Only two cases showed an irritant reaction on patch testing. 65% of the symptomatic personnel were atopic. There was no predisposing trade or age group for adverse effects to ATF. This study revealed that contact with ATF is associated with only mild irritant contact dermatitis in exposed ground crew members of the IAF and atopy was a predisposing factor for susceptibility to the dermatitis.

  9. 49 CFR 572.173 - Neck assembly and test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... respect to the pendulum's longitudinal centerline between 76 degrees and 90 degrees. During the time..., referenced in Figure T3, shall rotate in the direction of preimpact flight with respect to the pendulum's... occipital condyle. (3) Time zero is defined as the time of initial contact between the pendulum striker...

  10. 49 CFR 572.173 - Neck assembly and test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... respect to the pendulum's longitudinal centerline between 76 degrees and 90 degrees. During the time..., referenced in Figure T3, shall rotate in the direction of preimpact flight with respect to the pendulum's... occipital condyle. (3) Time zero is defined as the time of initial contact between the pendulum striker...

  11. 49 CFR 572.173 - Neck assembly and test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... respect to the pendulum's longitudinal centerline between 76 degrees and 90 degrees. During the time..., referenced in Figure T3, shall rotate in the direction of preimpact flight with respect to the pendulum's... occipital condyle. (3) Time zero is defined as the time of initial contact between the pendulum striker...

  12. 78 FR 55660 - Airworthiness Directives; Bombardier, Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-09-11

    ... Flight Test Branch, ANE-172, FAA, New York Aircraft Certification Office, 1600 Stewart Avenue, Suite 410.... We will post all comments we receive, without change, to http://www.regulations.gov , including any personal information you provide. We will also post a report summarizing each substantive verbal contact we...

  13. 77 FR 6023 - Airworthiness Directives; Airbus Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-02-07

    ... the closing date and may amend this proposed AD based on those comments. We will post all comments we.... We will also post a report summarizing each substantive verbal contact we receive about this proposed... (Cadensicon). During tests that were carried out applying 115V to the Cadensicon coil, measured temperature...

  14. 77 FR 32918 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-06-04

    ... require repetitive inspections for cracks and a chemical spot test in the area of station (STA) 908, and.... We will post all comments we receive, without change, to http://www.regulations.gov , including any personal information you provide. We will also post a report summarizing each substantive verbal contact we...

  15. 78 FR 61220 - Airworthiness Directives; Dassault Aviation Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-03

    .... We will post all comments we receive, without change, to http://www.regulations.gov , including any personal information you provide. We will also post a report summarizing each substantive verbal contact we...: During a test flight on a Falcon 2000EX equipped with winglets (commercial designation Falcon 2000LX...

  16. Identification, Curation, and Prioritization of Food-Use Chemicals in ToxCast (SOT)

    EPA Science Inventory

    Evaluating the thousands of chemicals that are directly added to or come in contact with food poses a great challenge due to the time, cost, and sheer volume of data necessary to thoroughly conduct comprehensive toxicological testing. This study compiled a list of food-use chemic...

  17. 78 FR 38826 - Airworthiness Directives; Various Helicopter Models

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-06-28

    ... results of the load inspection test. This AD is prompted by a report of a failure of the overload clutch... evaluation, any comments received, and other information. The street address for the Docket Operations Office... after receipt. For service information identified in this AD, contact: Goodrich Corporation, Sensors...

  18. 78 FR 21079 - Airworthiness Directives; Bombardier, Inc. Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-09

    ... accomplished. The initial inspection may be either a detailed inspection or a bolt- hole eddy current (BHEC... inspection or a bolt-hole eddy current (BHEC) test for cracking of each nacelle lower longeron, in accordance...-39, Revision A, dated August 2, 2012, specify to contact the manufacturer for instructions to repair...

  19. Finite-Element Analysis of a Mach-8 Flight Test Article Using Nonlinear Contact Elements

    NASA Technical Reports Server (NTRS)

    Richards, W. Lance

    1997-01-01

    A flight test article, called a glove, is required for a Mach-8 boundary-layer experiment to be conducted on a flight mission of the air-launched Pegasus(reg) space booster. The glove is required to provide a smooth, three-dimensional, structurally stable, aerodynamic surface and includes instrumentation to determine when and where boundary-layer transition occurs during the hypersonic flight trajectory. A restraint mechanism has been invented to attach the glove to the wing of the space booster. The restraint mechanism securely attaches the glove to the wing in directions normal to the wing/glove interface surface, but allows the glove to thermally expand and contract to alleviate stresses in directions parallel to the interface surface. A finite-element analysis has been performed using nonlinear contact elements to model the complex behavior of the sliding restraint mechanism. This paper provides an overview of the glove design and presents details of the analysis that were essential to demonstrate the flight worthiness of the wing-glove test article. Results show that all glove components are well within the allowable stress and deformation requirements to satisfy the objectives of the flight research experiment.

  20. Allergic contact dermatitis pattern in Kuwait: nickel leads the pack. In-depth analysis of nickel allergy based on the results from a large prospective patch test series report

    PubMed Central

    Almutawa, Fahad

    2017-01-01

    Introduction Contact dermatitis is a relatively common dermatosis reported among several population groups from all around the globe. However, the data from Kuwait is unavailable. Patch tests are essential for the diagnosis of contact sensitization. Aim To determine a relative frequency and pattern of sensitizers to different allergens in patients of suspected contact dermatitis in Kuwait and, also to study the role of the commonest sensitizer in detail. Material and methods Patch tests were performed in 2461 consecutive patients with a clinical diagnosis of contact dermatitis seen at our hospital between September 1, 2014 and August 31, 2015. Out of the total of 1381 (56.1%) patients with positive patch test results to at least one allergen, 546 (22.2%) patients with a single positive reaction to nickel only (single largest sensitizer) were selected as the study population for further detailed analysis. Results At least one positive patch test reaction was found in 1381 (56.12%) patients. Nickel was found to be the most common sensitizer seen in 546 (40%) patients. The mean age was 37.3 ±13.8 years and the mean duration of disease was 27.3 ±13.8 months. Most (387/546) patients sensitized were females. The forearms/hands and wrists were the most prevalent sites (52.56% of the participants). In 58.91% of women, dermatitis was more often confined to other sites, mostly ears and the neck due to earrings and necklaces. Just more than half of the number (51.09%) of nickel allergic patients were found in the age group of 15–25 years. Hairdressers/beauticians were the most affected group followed by house workers (housewives, cleaners, housekeepers). Conclusions Nickel is the single most common sensitizer found in our patients, and female sex, young age, occupation with long hours of contact to nickel are high risk factors. We recommend that a directive, which limits the release of nickel from products with extended skin contact, be approved in Kuwait. PMID:28670248

  1. Evaluation of effect of galvanic corrosion between nickel-chromium metal and titanium on ion release and cell toxicity

    PubMed Central

    Choi, Jung-Yun

    2015-01-01

    PURPOSE The purpose of this study was to evaluate cell toxicity due to ion release caused by galvanic corrosion as a result of contact between base metal and titanium. MATERIALS AND METHODS It was hypothesized that Nickel (Ni)-Chromium (Cr) alloys with different compositions possess different corrosion resistances when contacted with titanium abutment, and therefore in this study, specimens (10×10×1.5 mm) were fabricated using commercial pure titanium and 3 different types of Ni-Cr alloys (T3, Tilite, Bella bond plus) commonly used for metal ceramic restorations. The specimens were divided into 6 groups according to the composition of Ni-Cr alloy and contact with titanium. The experimental groups were in direct contact with titanium and the control groups were not. After the samples were immersed in the culture medium - Dulbecco's modified Eagle's medium[DMEM] for 48 hours, the released metal ions were detected using inductively coupled plasma mass spectrometer (ICP-MS) and analyzed by the Kruskal-Wallis and Mann-Whitney test (P<.05). Mouse L-929 fibroblast cells were used for cell toxicity evaluation. The cell toxicity of specimens was measured by the 3-{4,5-dimethylthiazol-2yl}-2,5-diphenyltetrazolium bromide (MTT) test. Results of MTT assay were statistically analyzed by the two-way ANOVA test (P<.05). Post-hoc multiple comparisons were conducted using Tukey's tests. RESULTS The amount of metal ions released by galvanic corrosion due to contact between the base metal alloy and titanium was increased in all of the specimens. In the cytotoxicity test, the two-way ANOVA showed a significant effect of the alloy type and galvanic corrosion for cytotoxicity (P<.001). The relative cell growth rate (RGR) was decreased further on the groups in contact with titanium (P<.05). CONCLUSION The release of metal ions was increased by galvanic corrosion due to contact between base metal and titanium, and it can cause adverse effects on the tissue around the implant by inducing cytotoxicity. PMID:25932317

  2. Haptic stabilization of posture: changes in arm proprioception and cutaneous feedback for different arm orientations

    NASA Technical Reports Server (NTRS)

    Rabin, E.; Bortolami, S. B.; DiZio, P.; Lackner, J. R.

    1999-01-01

    Postural sway during quiet stance is attenuated by actively maintained contact of the index finger with a stationary surface, even if the level of applied force (<1 N) cannot provide mechanical stabilization. In this situation, changes in force level at the fingertip lead changes in center of foot pressure by approximately 250 ms. These and related findings indicate that stimulation of the fingertip combined with proprioceptive information about the hand and arm can serve as an active sensor of body position relative to the point of contact. A geometric analysis of the relationship between hand and torso displacement during body sway led to the prediction that arm and hand proprioceptive and finger somatosensory information about body sway would be maximized with finger contact in the plane of body sway. Therefore, the most postural stabilization should be possible with such contact. To test this analysis, subjects touched a laterally versus anteriorly placed surface while in each of two stances: the heel-to-toe tandem Romberg stance that reduces medial-lateral stability and the heel-to-heel, toes-outward, knees-bent, "duck stance" that reduces fore-aft stability. Postural sway was always least with finger contact in the unstable plane: for the tandem stance, lateral fingertip contact was significantly more effective than frontal contact, and, for the duck stance, frontal contact was more effective than lateral fingertip contact. Force changes at the fingertip led changes in center of pressure of the feet by approximately 250 ms for both fingertip contact locations for both test stances. These results support the geometric analysis, which showed that 1) arm joint angles change by the largest amount when fingertip contact is maintained in the plane of greatest sway, and 2) the somatosensory cues at the fingertip provide both direction and amplitude information about sway when the finger is contacting a surface in the unstable plane.

  3. Haptic stabilization of posture: changes in arm proprioception and cutaneous feedback for different arm orientations.

    PubMed

    Rabin, E; Bortolami, S B; DiZio, P; Lackner, J R

    1999-12-01

    Postural sway during quiet stance is attenuated by actively maintained contact of the index finger with a stationary surface, even if the level of applied force (<1 N) cannot provide mechanical stabilization. In this situation, changes in force level at the fingertip lead changes in center of foot pressure by approximately 250 ms. These and related findings indicate that stimulation of the fingertip combined with proprioceptive information about the hand and arm can serve as an active sensor of body position relative to the point of contact. A geometric analysis of the relationship between hand and torso displacement during body sway led to the prediction that arm and hand proprioceptive and finger somatosensory information about body sway would be maximized with finger contact in the plane of body sway. Therefore, the most postural stabilization should be possible with such contact. To test this analysis, subjects touched a laterally versus anteriorly placed surface while in each of two stances: the heel-to-toe tandem Romberg stance that reduces medial-lateral stability and the heel-to-heel, toes-outward, knees-bent, "duck stance" that reduces fore-aft stability. Postural sway was always least with finger contact in the unstable plane: for the tandem stance, lateral fingertip contact was significantly more effective than frontal contact, and, for the duck stance, frontal contact was more effective than lateral fingertip contact. Force changes at the fingertip led changes in center of pressure of the feet by approximately 250 ms for both fingertip contact locations for both test stances. These results support the geometric analysis, which showed that 1) arm joint angles change by the largest amount when fingertip contact is maintained in the plane of greatest sway, and 2) the somatosensory cues at the fingertip provide both direction and amplitude information about sway when the finger is contacting a surface in the unstable plane.

  4. Traction behavior of two traction lubricants

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Rohn, D. A.

    1983-01-01

    In the analysis of rolling-sliding concentrated contacts, such as gears, bearings and traction drives, the traction characteristics of the lubricant are of prime importance. The elastic shear modulus and limiting shear stress properties of the lubricant dictate the traction/slip characteristics and power loss associated with an EHD contact undergoing slip and/or spin. These properties can be deducted directly from the initial slope m and maximum traction coefficient micron of an experimental traction curve. In this investigation, correlation equations are presented to predict m and micron for two modern traction fluids based on the regression analysis of 334 separate traction disk machine experiments. The effects of contact pressure, temperature, surface velocity, ellipticity ratio are examined. Problems in deducing lubricant shear moduli from disk machine tests are discussed.

  5. [Current contact allergens].

    PubMed

    Geier, J; Uter, W; Lessmann, H; Schnuch, A

    2011-10-01

    Ever-changing exposure to contact allergens, partly due to statutory directives (e.g. nickel, chromate, methyldibromo glutaronitrile) or recommendations from industrial associations (e.g. hydroxyisohexyl 3-cyclohexene carboxaldehyde), requires on-going epidemiologic surveillance of contact allergy. In this paper, the current state with special focus in fragrances and preservatives is described on the basis of data of the Information Network of Departments of Dermatology (IVDK) of the year 2010. In 2010, 12,574 patients were patch tested in the dermatology departments belonging to the IVDK. Nickel is still the most frequent contact allergen. However the continuously improved EU nickel directive already has some beneficial effect; sensitization frequency in young women is dropping. In Germany, chromate-reduced cement has been in use now for several years, leading to a decline in chromate sensitization in brick-layers. Two fragrance mixes are part of the German baseline series; they are still relevant. The most important fragrances in these mixes still are oak moss absolute and hydroxyisohexyl 3-cyclohexene carboxaldehyde. However, in relation to these leading allergens, sensitization frequency to other fragrances contained in the mixes seems to be increasing. Among the preservatives, MCI/MI has not lost its importance as contact allergen, in contrast to MDBGN. Sources of MCI/MI sensitization obviously are increasingly found in occupational context. Methylisothiazolinone is a significant allergen in occupational settings, and less frequently in body care products.

  6. Comparison of self-reported and observed water contact in an S. mansoni endemic village in Brazil.

    PubMed

    Friedman, J F; Kurtis, J D; McGarvey, S T; Fraga, A L; Silveira, A; Pizziolo, V; Gazzinelli, G; LoVerde, P; Corrêa-Oliveira, R

    2001-03-30

    Estimates of exposure are critical for immuno-epidemiologic and intervention studies in human schistosomiasis. Direct observation of human water contact patterns is both costly and time consuming. To address these issues, we determined whether individuals residing in a Schistosoma mansoni endemic village in Brazil could accurately self-report their water contact patterns. We compared the results of a water contact questionnaire to the present gold standard, direct observation of water contact in 86 volunteers, aged 8--29. We administered a survey to estimate volunteers' frequency and type of water contact and directly measured each volunteers' water contact patterns during 5 weeks of detailed water contact observations. We found a poor correlation between self reported frequency of contact and directly observed exposure (rho=0.119, P=NS). The questionnaire data was supplemented by information about average body surface area of exposure and duration of contact for specific activities derived from observations of this cohort. This 'supplemented questionnaire' data was significantly correlated with their exposure index (rho=0.227, P=0.05). It provides a starting point from which questionnaires may develop to provide a more cost-effective and less labor intensive method of assessing water contact exposure at the level of the individual.

  7. Coercive and Prosocial Fathering, Antisocial Personality, and Growth in Children's Post-Divorce Noncompliance

    PubMed Central

    DeGarmo, David S.

    2009-01-01

    The study employed multiple methods including direct observation of fathering behaviors and child noncompliance to better address our understanding of the quantity and quality of divorced father contact. A weighted county sample of 230 divorced-father families with a focal child aged 4 to 11 years was employed to test whether fathers' antisocial personality (ASP) moderated effects of monthly contact with children in predicting children's observed noncompliance over 18 months. Latent growth models obtained significant individual differences in levels of noncompliance and growth rates. ASP significantly moderated the beneficial impact of fathers' monthly contact. Fathers' observed parenting practices significantly predicted levels but not growth rates. Parenting did not account for the effect of Contact × ASP suggesting both environmental and potentially genetic influences on child adjustment. Findings were robust across boys and girls and age levels. Implications for preventive intervention are discussed. PMID:20438456

  8. Bio-knowledge based filters improve residue-residue contact prediction accuracy.

    PubMed

    Wozniak, P P; Pelc, J; Skrzypecki, M; Vriend, G; Kotulska, M

    2018-05-29

    Residue-residue contact prediction through direct coupling analysis has reached impressive accuracy, but yet higher accuracy will be needed to allow for routine modelling of protein structures. One way to improve the prediction accuracy is to filter predicted contacts using knowledge about the particular protein of interest or knowledge about protein structures in general. We focus on the latter and discuss a set of filters that can be used to remove false positive contact predictions. Each filter depends on one or a few cut-off parameters for which the filter performance was investigated. Combining all filters while using default parameters resulted for a test-set of 851 protein domains in the removal of 29% of the predictions of which 92% were indeed false positives. All data and scripts are available from http://comprec-lin.iiar.pwr.edu.pl/FPfilter/. malgorzata.kotulska@pwr.edu.pl. Supplementary data are available at Bioinformatics online.

  9. Characterizing Adhesion between a Micropatterned Surface and a Soft Synthetic Tissue.

    PubMed

    Kern, Madalyn D; Qi, Yuan; Long, Rong; Rentschler, Mark E

    2017-01-31

    The work of adhesion and work of separation are characteristic properties of a contact interface that describe the amount of energy per unit area required to adhere or separate two contacting substrates, respectively. In this work, the authors present experimental and data analysis procedures that allow the contact interface between a soft synthetic tissue and a smooth or micropatterned poly(dimethylsiloxane) (PDMS) substrate to be characterized in terms of these characteristic parameters. Because of physical geometry limitations, the experimental contact geometry chosen for this study differs from conventional test geometries. Therefore, the authors used finite element modeling to develop correction factors specific to the experimental contact geometry used in this work. A work of adhesion was directly extracted from experimental data while the work of separation was estimated on the basis of experimental results. These values are compared to other theoretical calculations for validation. The results of this work indicate that the micropatterned PDMS substrate significantly decreases both the work of adhesion and work of separation as compared to a smooth PDMS substrate when in contact with a soft synthetic tissue substrate.

  10. Physical validation of a patient-specific contact finite element model of the ankle.

    PubMed

    Anderson, Donald D; Goldsworthy, Jane K; Li, Wendy; James Rudert, M; Tochigi, Yuki; Brown, Thomas D

    2007-01-01

    A validation study was conducted to determine the extent to which computational ankle contact finite element (FE) results agreed with experimentally measured tibio-talar contact stress. Two cadaver ankles were loaded in separate test sessions, during which ankle contact stresses were measured with a high-resolution (Tekscan) pressure sensor. Corresponding contact FE analyses were subsequently performed for comparison. The agreement was good between FE-computed and experimentally measured mean (3.2% discrepancy for one ankle, 19.3% for the other) and maximum (1.5% and 6.2%) contact stress, as well as for contact area (1.7% and 14.9%). There was also excellent agreement between histograms of fractional areas of cartilage experiencing specific ranges of contact stress. Finally, point-by-point comparisons between the computed and measured contact stress distributions over the articular surface showed substantial agreement, with correlation coefficients of 90% for one ankle and 86% for the other. In the past, general qualitative, but little direct quantitative agreement has been demonstrated with articular joint contact FE models. The methods used for this validation enable formal comparison of computational and experimental results, and open the way for objective statistical measures of regional correlation between FE-computed contact stress distributions from comparison articular joint surfaces (e.g., those from an intact versus those with residual intra-articular fracture incongruity).

  11. Advanced Stirling Convertor Durability Testing: Plans and Interim Results

    NASA Technical Reports Server (NTRS)

    Meer, David W.; Oriti, Salvatore M.

    2012-01-01

    The U.S. Department of Energy (DOE), Lockheed Martin Corporation (LM), and NASA Glenn Research Center (GRC) have been developing the Advanced Stirling Radioisotope Generator (ASRG) for use as a power system for space science missions. In support of this program, GRC has been involved in testing Stirling convertors, including the Advanced Stirling Convertor (ASC), for use in the ASRG. This testing includes electromagnetic interference/compatibility (EMI/EMC), structural dynamics, advanced materials, organics, and unattended extended operation. The purpose of the durability tests is to experimentally demonstrate the margins in the ASC design. Due to the high value of the hardware, previous ASC tests focused on establishing baseline performance of the convertors within the nominal operating conditions. The durability tests present the first planned extension of the operating conditions into regions beyond those intended to meet the product spec, where the possibility exists of lateral contact, overstroke, or over-temperature events. These tests are not intended to cause damage that would shorten the life of the convertors, so they can transition into extended operation at the conclusion of the tests. This paper describes the four tests included in the durability test sequence: 1) start/stop cycling, 2) exposure to constant acceleration in the lateral and axial directions, 3) random vibration at increased piston amplitude to induce contact events, and 4) overstroke testing to simulate potential failures during processing or during the mission life where contact events could occur. The paper also summarizes the analysis and simulation used to predict the results of each of these tests.

  12. Micro-macro correlations and anisotropy in granular assemblies under uniaxial loading and unloading.

    PubMed

    Imole, Olukayode I; Wojtkowski, Mateusz; Magnanimo, Vanessa; Luding, Stefan

    2014-04-01

    The influence of contact friction on the behavior of dense, polydisperse granular assemblies under uniaxial (oedometric) loading and unloading deformation is studied using discrete element simulations. Even though the uniaxial deformation protocol is one of the "simplest" element tests possible, the evolution of the structural anisotropy necessitates its careful analysis and understanding, since it is the source of interesting and unexpected observations. On the macroscopic, homogenized, continuum scale, the deviatoric stress ratio and the deviatoric fabric, i.e., the microstructure behave in a different fashion during uniaxial loading and unloading. The maximal stress ratio and strain increase with increasing contact friction. In contrast, the deviatoric fabric reaches its maximum at a unique strain level independent of friction, with the maximal value decreasing with friction. For unloading, both stress and fabric respond to unloading strain with a friction-dependent delay but at different strains. On the micro-level, a friction-dependent non-symmetry of the proportion of weak (strong) and sliding (sticking) contacts with respect to the total contacts during loading and unloading is observed. Coupled to this, from the directional probability distribution, the "memory" and history-dependent behavior of granular systems is confirmed. Surprisingly, while a rank-2 tensor is sufficient to describe the evolution of the normal force directions, a sixth order harmonic approximation is necessary to describe the probability distribution of contacts, tangential force, and mobilized friction. We conclude that the simple uniaxial deformation activates microscopic phenomena not only in the active Cartesian directions, but also at intermediate orientations, with the tilt angle being dependent on friction, so that this microstructural features cause the interesting, nontrivial macroscopic behavior.

  13. Water Landing Characteristics of a Reentry Capsule

    NASA Technical Reports Server (NTRS)

    1958-01-01

    Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.

  14. Water-Landing Characteristics of a Reentry Capsule

    NASA Technical Reports Server (NTRS)

    McGehee, John R.; Hathaway, Melvin E.; Vaughan, Victor L., Jr.

    1959-01-01

    Experimental and theoretical investigations have been made to determine the water-landing characteristics of a conical-shaped reentry capsule having a segment of a sphere as the bottom. For the experimental portion of the investigation, a 1/12-scale model capsule and a full-scale capsule were tested for nominal flight paths of 65 deg and 90 deg (vertical), a range of contact attitudes from -30 deg to 30 deg, and a full-scale vertical velocity of 30 feet per second at contact. Accelerations were measured by accelerometers installed at the centers of gravity of the model and full-scale capsules. For the model test the accelerations were measured along the X-axis (roll) and Z-axis (yaw) and for the full-scale test they were measured along the X-axis (roll), Y-axis (pitch), and Z-axis (yaw). Motions and displacements of the capsules that occurred after contact were determined from high-speed motion pictures. The theoretical investigation was conducted to determine the accelerations that might occur along the X-axis when the capsule contacted the water from a 90 deg flight path at a 0 deg attitude. Assuming a rigid body, computations were made from equations obtained by utilizing the principle of the conservation of momentum. The agreement among data obtained from the model test, the full-scale test, and the theory was very good. The accelerations along the X-axis, for a vertical flight path and 0 deg attitude, were in the order of 40g. For a 65 deg flight path and 0 deg attitude, the accelerations along the X-axis were in the order of 50g. Changes in contact attitude, in either the positive or negative direction from 0 deg attitude, considerably reduced the magnitude of the accelerations measured along the X-axis. Accelerations measured along the Y- and Z-axes were relatively small at all test conditions.

  15. Asymptomatic infection and unrecognised Ebola virus disease in Ebola-affected households in Sierra Leone: a cross-sectional study using a new non-invasive assay for antibodies to Ebola virus.

    PubMed

    Glynn, Judith R; Bower, Hilary; Johnson, Sembia; Houlihan, Catherine F; Montesano, Carla; Scott, Janet T; Semple, Malcolm G; Bangura, Mohammed S; Kamara, Alie Joshua; Kamara, Osman; Mansaray, Saidu H; Sesay, Daniel; Turay, Cecilia; Dicks, Steven; Wadoum, Raoul E Guetiya; Colizzi, Vittorio; Checchi, Francesco; Samuel, Dhan; Tedder, Richard S

    2017-06-01

    The frequency of asymptomatic infection with Ebola virus is unclear: previous estimates vary and there is no standard test. Asymptomatic infection with Ebola virus could contribute to population immunity, reducing spread. If people with asymptomatic infection are infectious it could explain re-emergences of Ebola virus disease (EVD) without known contact. We validated a new oral fluid anti-glycoprotein IgG capture assay among survivors from Kerry Town Ebola Treatment Centre and controls from communities unaffected by EVD in Sierra Leone. We then assessed the seroprevalence of antibodies to Ebola virus in a cross-sectional study of household contacts of the survivors. All household members were interviewed. Two reactive tests were required for a positive result, with a third test to resolve any discrepancies. The assay had a specificity of 100% (95% CI 98·9-100; 339 of 339 controls tested negative) and sensitivity of 95·9% (89·8-98·9; 93 of 97 PCR-confirmed survivors tested positive). Of household contacts not diagnosed with EVD, 47·6% (229 of 481) had high level exposure (direct contact with a corpse, body fluids, or a case with diarrhoea, vomiting, or bleeding). Among the contacts, 12·0% (95% CI 6·1-20·4; 11 of 92) with symptoms at the time other household members had EVD, and 2·6% (1·2-4·7; 10 of 388) with no symptoms tested positive. Among asymptomatic contacts, seropositivity was weakly correlated with exposure level. This new highly specific and sensitive assay showed asymptomatic infection with Ebola virus was uncommon despite high exposure. The low prevalence suggests asymptomatic infection contributes little to herd immunity in Ebola, and even if infectious, would account for few transmissions. Wellcome Trust ERAES Programme, Save the Children. Copyright © 2017 The Author(s). Published by Elsevier Ltd. This is an Open Access article under the CC BY license. Published by Elsevier Ltd.. All rights reserved.

  16. Healthcare Industry Injuries by Patient Contact Status in Kentucky, 2012-2014.

    PubMed

    Ranzenberger, Kristen; Bunn, Terry L; Slavova, Svetla

    2016-10-01

    The healthcare industry continues to have a high number of reported injuries. The purpose of this study was to characterize healthcare industry injuries by patient contact status, identify the occupations associated with healthcare injuries by patient contact status, and determine healthcare injury rates by occupation to gain a better understanding of healthcare industry-compensated injuries and better target safety practices and programs in the healthcare industry. Kentucky healthcare industry workers' compensation first reports of injuries from calendar years 2012-2014 were categorized into injuries involved in direct patient contact versus injuries without direct patient contact using narrative text analysis. Injury numbers and rates were calculated for a number of data variables. Healthcare injuries without direct patient contact (55% of all first reports of injuries) occurred more frequently among older workers (45 years old and older [51%]), in "other" occupations such as housekeeping and maintenance (28%), and as a result of falls/slips/trips (39%) and sprains/tears (38%). In contrast, a higher percentage of healthcare injuries involving direct patient contact occurred among workers younger than 35 years (48%), in healthcare support occupations (50%), and resulting from sprains/tears (66%) and lifting/handling (52%), compared with those without direct patient contact. Findings from this study can better target the need for new and/or additional specific workplace safety training, especially in the healthcare support and nursing occupations with and without patient contact.

  17. Plasma contactor technology for Space Station Freedom

    NASA Technical Reports Server (NTRS)

    Patterson, Michael J.; Hamley, John A.; Sarver-Verhey, Timothy; Soulas, George C.; Parkes, James; Ohlinger, Wayne L.; Schaffner, Michael S.; Nelson, Amy

    1993-01-01

    Hollow cathode plasma contactors were baselined for Space Station Freedom (SSF) to control the electrical potentials of surfaces to eliminate/mitigate damaging interactions with the space environment. The system represents a dual-use technology which is a direct outgrowth of the NASA electric propulsion program and in particular the technology development effort on ion thruster systems. Specific efforts include optimizing the design and configuration of the contactor, validating its required lifetime, and characterizing the contactor plume and electromagnetic interference. The plasma contact or subsystems include the plasma contact or unit, a power electronics unit, and an expellant management unit. Under this program these will all be brought to breadboard and engineering model development status. New test facilities were developed, and existing facilities were augmented, to support characterizations and life testing of contactor components and systems. The magnitude, scope, and status of the plasma contactor hardware development program now underway and preliminary test results on system components are discussed.

  18. In the eye of the beholder: eye contact increases resistance to persuasion.

    PubMed

    Chen, Frances S; Minson, Julia A; Schöne, Maren; Heinrichs, Markus

    2013-11-01

    Popular belief holds that eye contact increases the success of persuasive communication, and prior research suggests that speakers who direct their gaze more toward their listeners are perceived as more persuasive. In contrast, we demonstrate that more eye contact between the listener and speaker during persuasive communication predicts less attitude change in the direction advocated. In Study 1, participants freely watched videos of speakers expressing various views on controversial sociopolitical issues. Greater direct gaze at the speaker's eyes was associated with less attitude change in the direction advocated by the speaker. In Study 2, we instructed participants to look at either the eyes or the mouths of speakers presenting arguments counter to participants' own attitudes. Intentionally maintaining direct eye contact led to less persuasion than did gazing at the mouth. These findings suggest that efforts at increasing eye contact may be counterproductive across a variety of persuasion contexts.

  19. Effect of Fiber Orientation on Ball Failures Under Rolling-contact Conditions

    NASA Technical Reports Server (NTRS)

    Butler, Robert H; Bear, H Robert; Carter, Thomas L

    1957-01-01

    The rolling-contact fatigue spin rig was used to test bails of a bearing steel at maximum Hertz stresses of 600,000 to 750,000 psi. The effect of fiber orientation was observed with the ball track restricted to passing directly over the poles, coincident with the equator, or randomly around the ball. The polar areas were found to be weaker in fatigue than the nonpolar areas. This resulted in a much greater portion of the failures occurring in the polar areas than would be expected from a homogeneous material. The early failures are discussed.

  20. Measles on the edge: coastal heterogeneities and infection dynamics.

    PubMed

    Bharti, Nita; Xia, Yingcun; Bjornstad, Ottar N; Grenfell, Bryan T

    2008-04-09

    Mathematical models can help elucidate the spatio-temporal dynamics of epidemics as well as the impact of control measures. The gravity model for directly transmitted diseases is currently one of the most parsimonious models for spatial epidemic spread. This model uses distance-weighted, population size-dependent coupling to estimate host movement and disease incidence in metapopulations. The model captures overall measles dynamics in terms of underlying human movement in pre-vaccination England and Wales (previously established). In spatial models, edges often present a special challenge. Therefore, to test the model's robustness, we analyzed gravity model incidence predictions for coastal cities in England and Wales. Results show that, although predictions are accurate for inland towns, they significantly underestimate coastal persistence. We examine incidence, outbreak seasonality, and public transportation records, to show that the model's inaccuracies stem from an underestimation of total contacts per individual along the coast. We rescue this predicted 'edge effect' by increasing coastal contacts to approximate the number of per capita inland contacts. These results illustrate the impact of 'edge effects' on epidemic metapopulations in general and illustrate directions for the refinement of spatiotemporal epidemic models.

  1. Predicting Transmembrane Helix Packing Arrangements using Residue Contacts and a Force-Directed Algorithm

    PubMed Central

    Nugent, Timothy; Jones, David T.

    2010-01-01

    Alpha-helical transmembrane proteins constitute roughly 30% of a typical genome and are involved in a wide variety of important biological processes including cell signalling, transport of membrane-impermeable molecules and cell recognition. Despite significant efforts to predict transmembrane protein topology, comparatively little attention has been directed toward developing a method to pack the helices together. Here, we present a novel approach to predict lipid exposure, residue contacts, helix-helix interactions and finally the optimal helical packing arrangement of transmembrane proteins. Using molecular dynamics data, we have trained and cross-validated a support vector machine (SVM) classifier to predict per residue lipid exposure with 69% accuracy. This information is combined with additional features to train a second SVM to predict residue contacts which are then used to determine helix-helix interaction with up to 65% accuracy under stringent cross-validation on a non-redundant test set. Our method is also able to discriminate native from decoy helical packing arrangements with up to 70% accuracy. Finally, we employ a force-directed algorithm to construct the optimal helical packing arrangement which demonstrates success for proteins containing up to 13 transmembrane helices. This software is freely available as source code from http://bioinf.cs.ucl.ac.uk/memsat/mempack/. PMID:20333233

  2. 77 FR 61731 - Airworthiness Directives; The Boeing Company Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-10-11

    ... actions; and repetitive engine fuel suction feed operational tests. Since we issued that AD, we received a... the closing date and may amend this proposed AD because of those comments. We will post all comments... provide. We will also post a report summarizing each substantive verbal contact we receive about this...

  3. 77 FR 48503 - Proposed Information Collection; Comment Request; National Voluntary Laboratory Accreditation...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-14

    ... instrument and instructions should be directed to the attention of Vanda R. White, National Voluntary..., Gaithersburg, MD 20899-2140; phone: (301) 975-3592; email: vanda.white@nist.gov . SUPPLEMENTARY INFORMATION: I... provide information, such as name, address, phone and fax numbers, contact person(s), and select the test...

  4. Decay of wood and wood-based products above ground in buildings

    Treesearch

    Charles G. Carll; Terry L. Highley

    1999-01-01

    This paper is an overview of what we know about occurrence of wood decay above ground within buildings. It presents information concerning under what conditions decay may become established. In laboratory tests involving optimum moisture and temperature conditions for decay fungi, and direct contact with large quantities of specific well-developed decay...

  5. Understanding the Effects of Cognitive Dissonance during Interpretation: Implications for "Hands-On" Programming.

    ERIC Educational Resources Information Center

    Morgan, Mark

    1996-01-01

    Describes a field experiment that was designed to test the effects of three different interpretive programs on students' attitudes toward live, nonpoisonous snakes. One of the treatments measured the effectiveness of using "hands-on" interpretive techniques. Direct contact with snakes improved students' attitudes but only slightly. Females'…

  6. Identification of residue pairing in interacting β-strands from a predicted residue contact map.

    PubMed

    Mao, Wenzhi; Wang, Tong; Zhang, Wenxuan; Gong, Haipeng

    2018-04-19

    Despite the rapid progress of protein residue contact prediction, predicted residue contact maps frequently contain many errors. However, information of residue pairing in β strands could be extracted from a noisy contact map, due to the presence of characteristic contact patterns in β-β interactions. This information may benefit the tertiary structure prediction of mainly β proteins. In this work, we propose a novel ridge-detection-based β-β contact predictor to identify residue pairing in β strands from any predicted residue contact map. Our algorithm RDb 2 C adopts ridge detection, a well-developed technique in computer image processing, to capture consecutive residue contacts, and then utilizes a novel multi-stage random forest framework to integrate the ridge information and additional features for prediction. Starting from the predicted contact map of CCMpred, RDb 2 C remarkably outperforms all state-of-the-art methods on two conventional test sets of β proteins (BetaSheet916 and BetaSheet1452), and achieves F1-scores of ~ 62% and ~ 76% at the residue level and strand level, respectively. Taking the prediction of the more advanced RaptorX-Contact as input, RDb 2 C achieves impressively higher performance, with F1-scores reaching ~ 76% and ~ 86% at the residue level and strand level, respectively. In a test of structural modeling using the top 1 L predicted contacts as constraints, for 61 mainly β proteins, the average TM-score achieves 0.442 when using the raw RaptorX-Contact prediction, but increases to 0.506 when using the improved prediction by RDb 2 C. Our method can significantly improve the prediction of β-β contacts from any predicted residue contact maps. Prediction results of our algorithm could be directly applied to effectively facilitate the practical structure prediction of mainly β proteins. All source data and codes are available at http://166.111.152.91/Downloads.html or the GitHub address of https://github.com/wzmao/RDb2C .

  7. Contact sponge water absorption test implemented for in situ measures

    NASA Astrophysics Data System (ADS)

    Gaggero, Laura; Scrivano, Simona

    2016-04-01

    The contact sponge method is a non-destructive in-situ methodology used to estimate a water uptake coefficient. The procedure, unlike other in-situ measurement was proven to be directly comparable to the water uptake laboratory measurements, and was registered as UNI 11432:2011. The UNI Normal procedure requires to use a sponge with known density, soaked in water, weighed, placed on the material for 1 minute (UNI 11432, 2011; Pardini & Tiano, 2004), then weighed again. Difficulties arise in operating on test samples or on materials with porosity varied for decay. While carrying on the test, fluctuations in the bearing of the environmental parameters were negligible, but not the pressure applied to the surface, that induced the release of different water amounts towards the material. For this reason we designed a metal piece of the same diameter of the plate carrying the sponge, to be screwed at the tip of a pocket penetrometer. With this instrument the sponge was kept in contact with the surface for 1 minute applying two different loads, at first pushed with 0.3 kg/cm2 in order to press the sponge, but not its holder, against the surface. Then, a load of 1.1 kg/ cm2 was applied, still avoiding deviating the load to the sponge holder. We applied both the current and our implemented method to determine the water absorption by contact sponge on 5 fresh rock types (4 limestones: Fine - and Coarse grained Pietra di Vicenza, Rosso Verona, Breccia Aurora, and the silicoclastic Macigno sandstone). The results show that 1) the current methodology imply manual skill and experience to produce a coherent set of data; the variable involved are in fact not only the imposed pressure but also the compression mechanics. 2) The control on the applied pressure allowed reproducible measurements. Moreover, 3) the use of a thicker sponge enabled to apply the method even on rougher surfaces, as the device holding the sponge is not in contact with the tested object. Finally, 4) the implemented measurements gave the possibility of a direct comparison with the capillary water absorption method. Pardini C. & Tiano P. 2004. Valutazione in situ dei trattamenti protettivi per il materiale lapideo, proposta di una nuova semplice metodologia. ARKOS, 5, 30-36. UNI 11432. 2011. Beni culturali Materiali lapidei naturali ed artificiali - Misura della capacita di assorbimento di acqua mediante spugna di contatto. P. 6.

  8. Computational modelling of cell chain migration reveals mechanisms that sustain follow-the-leader behaviour

    PubMed Central

    Wynn, Michelle L.; Kulesa, Paul M.; Schnell, Santiago

    2012-01-01

    Follow-the-leader chain migration is a striking cell migratory behaviour observed during vertebrate development, adult neurogenesis and cancer metastasis. Although cell–cell contact and extracellular matrix (ECM) cues have been proposed to promote this phenomenon, mechanisms that underlie chain migration persistence remain unclear. Here, we developed a quantitative agent-based modelling framework to test mechanistic hypotheses of chain migration persistence. We defined chain migration and its persistence based on evidence from the highly migratory neural crest model system, where cells within a chain extend and retract filopodia in short-lived cell contacts and move together as a collective. In our agent-based simulations, we began with a set of agents arranged as a chain and systematically probed the influence of model parameters to identify factors critical to the maintenance of the chain migration pattern. We discovered that chain migration persistence requires a high degree of directional bias in both lead and follower cells towards the target. Chain migration persistence was also promoted when lead cells maintained cell contact with followers, but not vice-versa. Finally, providing a path of least resistance in the ECM was not sufficient alone to drive chain persistence. Our results indicate that chain migration persistence depends on the interplay of directional cell movement and biased cell–cell contact. PMID:22219399

  9. Familiarity breeds contempt: combining proximity loggers and GPS reveals female white-tailed deer (Odocoileus virginianus) avoiding close contact with neighbors.

    PubMed

    Tosa, Marie I; Schauber, Eric M; Nielsen, Clayton K

    2015-01-01

    Social interactions can influence infectious disease dynamics, particularly for directly transmitted pathogens. Therefore, reliable information on contact frequency within and among groups can better inform disease modeling and management. We compared three methods of assessing contact patterns: (1) space-use overlap (volume of interaction [VI]), (2) direct contact rates measured by simultaneous global positioning system (GPS) locations (<10 m apart), and (3) direct contact rates measured by proximity loggers (PLs; 1-m detection) among female white-tailed deer (Odocoileus virginianus). We calculated the PL∶GPS contact ratios to see whether both devices reveal similar contact patterns and thus predict similar pathogen transmission patterns. Contact rates measured by GPS and PLs were similarly high for two within-group dyads (pairs of deer in the same social groups). Dyads representing separate but neighboring groups (high VI) had PL∶GPS contact ratios near zero, whereas dyads further apart (intermediate VI) had higher PL∶GPS contact ratios. Social networks based on PL contacts showed the fewest connected individuals and lowest mean centrality measures; network metrics were intermediate when based on GPS contacts and greatest when based on VI. Thus, the VI network portrayed animals to be more uniformly and strongly connected than did the PL network. We conclude that simultaneous GPS locations, compared with PLs, substantially underestimate the impact of group membership on direct contact rates of female deer and make networks appear more connected. We also present evidence that deer coming within the general vicinity of each other are less likely to come in close contact if they are in neighboring social groups than deer whose home ranges overlap little if at all. Combined, these results provide evidence that direct transmission of disease agents among female and juvenile white-tailed deer is likely to be constrained both spatially and by social structure, more so than GPS data alone would suggest.

  10. An investigation of rolling-sliding contact fatigue damage of carburized gear steels

    NASA Astrophysics Data System (ADS)

    Kramer, Patrick C.

    The goal of this study was to evaluate the differences in RSCF performance between vacuum and gas carburized steels as well as to investigate the evolution of damage (wear and microstructure changes) leading to pitting. Vacuum and gas carburizing was performed on two gear steels (4120 and 4320) at 1010°C. The carburized specimens were tested in the as-carburized condition using a RSCF machine designed and built at the Colorado School of Mines. The tests were conducted at 3.2 GPa nominal Hertzian contact stress, based on pure rolling, 100°C, and using a negative twenty percent slide ratio. Tests were conducted to pitting failure for each condition for a comparison of the average fatigue lives. Pure rolling tests were also conducted, and were suspended at the same number of cycles as the average RSCF life for a comparison of fatigue damage developed by RCF and RSCF. Incremental tests were suspended at 1,000, 10,000, 100,000, and 200,000 cycles for the vacuum carburized steels to evaluate the wear and damage developed during the initial cycles of RSCF testing and to relate the wear and damage to pitting resistance. Incremental damage was not investigated for gas carburizing due to the limited number of available specimens. The vacuum carburized samples showed a decreased pitting fatigue resistance over the gas carburized samples, possibly due to the presence of bainite in the vacuum carburized cases. Pitting was observed to initiate from surface micropitting and microcracking. A microstructural change induced by contact fatigue, butterflies, was shown to contribute to micropitting and microcracking. Incremental testing revealed that the formation of a microcrack preceded and was necessary for the formation of the butterfly features, and that the butterfly features developed between 10,000 and 100,000 cycles. The orientation and depth of butterfly formation was shown to be dependent upon the application of traction stresses from sliding. RSCF butterflies formed nearly parallel to the rolling direction at a large range of depths. RCF butterflies formed at about 45° to the rolling direction in a more narrow range of depths. The surface roughness and surface profile were observed to change quickly in the first several thousand cycles of RSCF testing leading to a reduction in contact stress and increase in lambda ratio (ratio of lubricant fluid film thickness to composite surface roughness). The ability of a carburized sample wear track to reach and maintain a steady state morphology (run-in condition) during testing is postulated to translate to increased RSCF resistance.

  11. Leptospirosis outbreak following severe flooding: a rapid assessment and mass prophylaxis campaign; Guyana, January-February 2005.

    PubMed

    Dechet, Amy M; Parsons, Michele; Rambaran, Madan; Mohamed-Rambaran, Pheona; Florendo-Cumbermack, Anita; Persaud, Shamdeo; Baboolal, Shirematee; Ari, Mary D; Shadomy, Sean V; Zaki, Sherif R; Paddock, Christopher D; Clark, Thomas A; Harris, Lazenia; Lyon, Douglas; Mintz, Eric D

    2012-01-01

    Leptospirosis is a zoonosis usually transmitted through contact with water or soil contaminated with urine from infected animals. Severe flooding can put individuals at greater risk for contracting leptospirosis in endemic areas. Rapid testing for the disease and large-scale interventions are necessary to identify and control infection. We describe a leptospirosis outbreak following severe flooding and a mass chemoprophylaxis campaign in Guyana. From January-March 2005, we collected data on suspected leptospirosis hospitalizations and deaths. Laboratory testing included anti-leptospiral dot enzyme immunoassay (DST), immunohistochemistry (IHC) staining, and microscopic agglutination testing (MAT). DST testing was conducted for 105 (44%) of 236 patients; 52 (50%) tested positive. Four (57%) paired serum samples tested by MAT were confirmed leptospirosis. Of 34 total deaths attributed to leptospirosis, postmortem samples from 10 (83%) of 12 patients were positive by IHC. Of 201 patients interviewed, 89% reported direct contact with flood waters. A 3-week doxycycline chemoprophylaxis campaign reached over 280,000 people. A confirmed leptospirosis outbreak in Guyana occurred after severe flooding, resulting in a massive chemoprophylaxis campaign to try to limit morbidity and mortality.

  12. Compatibility tests between Jarytherm DBT synthetic oil and solid materials from wastes

    NASA Astrophysics Data System (ADS)

    Fasquelle, Thomas; Falcoz, Quentin; Neveu, Pierre; Flamant, Gilles; Walker, Jérémie

    2016-05-01

    Direct thermocline thermal energy storage is the cheapest sensible thermal energy storage configuration. Indeed, a thermocline tank consists in one tank instead of two and reduces costs. Thermocline thermal energy storages are often filled with cheap solid materials which could react with the heat transfer fluid in the case of incompatibility. PROMES laboratory is building a pilot-scale parabolic trough solar loop including a direct thermocline thermal energy storage system. The working fluid will be a synthetic oil, the Jarytherm® DBT, and the thermal energy storage tank will be filled with stabilized solid materials elaborated from vitrified wastes. Compatibility tests have been conducted in order to check on one hand if the thermo-mechanical properties and life time of the energy storage medium are not affected by the contact with oil and, on the other hand, if the thermal oil performances are not degraded by the solid filler. These experiments consisted in putting in contact the oil and the solid materials in small tanks. In order to discriminate the solid materials tested in the shortest time, accelerating aging conditions at 330 °C for 500 hours were used. The measurements consisted in X-Ray Diffraction and Scanning Electron Microscopy for the solids, and thermo-physical and chemical properties measurements for the oil. Regarding the solid samples, their crystalline structure did not change during the test, but it is difficult to conclude about their elementary composition and they seem to absorb oil. While thermal properties still makes Jarytherm® DBT a good heat transfer fluid after the accelerated aging tests, this study results in differentiating most compatible materials. Thus according to our study, Jarytherm® DBT can be used in direct thermocline thermal energy storage applications when compatibility of the solid material has been demonstrated.

  13. Bradbury

    Science.gov Websites

    Search Site submit About | Contacts | Directions Los Alamos National LaboratoryBradbury Science Museum Your Window into Los Alamos National Laboratory Bradbury Science Museum Menu About Contacts Directions Visit Visitor Information About the Museum Large Group Visits Around Los Alamos Contact Us

  14. The effect of antibiotics on social aversion following early life inflammation.

    PubMed

    Kentner, Amanda C; Khan, Urma; MacRae, M; Dowd, Scot E; Yan, Siyang

    2018-06-13

    Epidemiological evidence suggests that exposure to infection during early development increases the risk for neurodevelopmental disorders associated with symptoms such as a decreased desire to engage in social interactions. In animals, disruptions in social behavior can be modelled by administering bacterial mimetics such as liposaccharide (LPS). However, when evaluating social interactions in the laboratory, attention is rarely directed on the reciprocal relationship as a whole, which is important as peers may drive social withdrawal. Previously, we have shown that male adolescent rats treated neonatally (n) with LPS receive less contact from their conspecifics in a social interaction test, and that this effect is mediated through olfactory communication. In the present study, we reconfirmed this effect using a more direct social test and evaluated the hypothesis that changes in the microbiome underlie the olfactory induced social aversion. Male and female Sprague-Dawley rats were administered nLPS (50 μg/kg, i.p) or nSaline on postnatal days (P)3 and 5. On P40, adolescent nLPS treated males received less contact in a social preference test compared to nSaline treated controls, an effect not observed in females. To confirm that nLPS led male rats to elicit a scent cue, resulting in social aversion, a subset of neurotypical conspecifics underwent an anosmia procedure that disrupted their olfactory processing via olfactory neuroepithelium degeneration. This normalized the contact that they directed towards nLPS and nSaline male rats. Although 16 s rRNA sequencing failed to detect significant differences in bacterial phyla across either sex or neonatal treatment, treating male nLPS rats with an antibiotic cocktail, which induced clear changes in microbial communities, diminished the social rejection effect. Therefore, manipulation of the microbiome appears to affect social communication where there exists an underlying deficit. Moreover, our data reaffirm that social engagement is a reciprocal process and the behavior of all individuals within a dynamic interaction should be evaluated. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Method and apparatus for high-efficiency direct contact condensation

    DOEpatents

    Bharathan, D.; Parent, Y.; Hassani, A.V.

    1999-07-20

    A direct contact condenser having a downward vapor flow chamber and an upward vapor flow chamber, wherein each of the vapor flow chambers includes a plurality of cooling liquid supplying pipes and a vapor-liquid contact medium disposed thereunder to facilitate contact and direct heat exchange between the vapor and cooling liquid. The contact medium includes a plurality of sheets arranged to form vertical interleaved channels or passageways for the vapor and cooling liquid streams. The upward vapor flow chamber also includes a second set of cooling liquid supplying pipes disposed beneath the vapor-liquid contact medium which operate intermittently in response to a pressure differential within the upward vapor flow chamber. The condenser further includes separate wells for collecting condensate and cooling liquid from each of the vapor flow chambers. In alternate embodiments, the condenser includes a cross-current flow chamber and an upward flow chamber, a plurality of upward flow chambers, or a single upward flow chamber. The method of use of the direct contact condenser of this invention includes passing a vapor stream sequentially through the downward and upward vapor flow chambers, where the vapor is condensed as a result of heat exchange with the cooling liquid in the contact medium. The concentration of noncondensable gases in the resulting condensate-liquid mixtures can be minimized by controlling the partial pressure of the vapor, which depends in part upon the geometry of the vapor-liquid contact medium. In another aspect of this invention, the physical and chemical performance of a direct contact condenser can be predicted based on the vapor and coolant compositions, the condensation conditions, and the geometric properties of the contact medium. 39 figs.

  16. Method and apparatus for high-efficiency direct contact condensation

    DOEpatents

    Bharathan, Desikan; Parent, Yves; Hassani, A. Vahab

    1999-01-01

    A direct contact condenser having a downward vapor flow chamber and an upward vapor flow chamber, wherein each of the vapor flow chambers includes a plurality of cooling liquid supplying pipes and a vapor-liquid contact medium disposed thereunder to facilitate contact and direct heat exchange between the vapor and cooling liquid. The contact medium includes a plurality of sheets arranged to form vertical interleaved channels or passageways for the vapor and cooling liquid streams. The upward vapor flow chamber also includes a second set of cooling liquid supplying pipes disposed beneath the vapor-liquid contact medium which operate intermittently in response to a pressure differential within the upward vapor flow chamber. The condenser further includes separate wells for collecting condensate and cooling liquid from each of the vapor flow chambers. In alternate embodiments, the condenser includes a cross-current flow chamber and an upward flow chamber, a plurality of upward flow chambers, or a single upward flow chamber. The method of use of the direct contact condenser of this invention includes passing a vapor stream sequentially through the downward and upward vapor flow chambers, where the vapor is condensed as a result of heat exchange with the cooling liquid in the contact medium. The concentration of noncondensable gases in the resulting condensate-liquid mixtures can be minimized by controlling the partial pressure of the vapor, which depends in part upon the geometry of the vapor-liquid contact medium. In another aspect of this invention, the physical and chemical performance of a direct contact condenser can be predicted based on the vapor and coolant compositions, the condensation conditions. and the geometric properties of the contact medium.

  17. Nickel on the Swedish market. Follow-up after implementation of the Nickel Directive.

    PubMed

    Lidén, Carola; Norberg, Kristina

    2005-01-01

    The Nickel Directive aims at the prevention of sensitization and elicitation of nickel dermatitis. It limits nickel release from, and nickel content in, certain items. The Directive came into full force by July 2001. The aim of this study was to investigate the frequency on the market of items that release nickel and of nickel content in piercing posts, 2 years after coming into force of the Directive. Of special interest was to study changes compared to the situation in 1999, when a baseline study had been carried out. Nickel release from 786 items covered by the Nickel Directive was tested with the dimethylglyoxime (DMG) test, and nickel content in 18 piercing posts was analysed. Nickel release was shown from 8% of items intended for direct and prolonged contact with the skin, and 17% of the piercing posts contained too much nickel, a decrease compared to 1999. There has been significant adaptation to the requirements of the Nickel Directive. The DMG test is useful for screening for nickel release and for monitoring the market. Provided there is further adaptation to the requirements, the risk of sensitization and elicitation of nickel dermatitis will be significantly reduced.

  18. Bradbury Science Museum

    Science.gov Websites

    Search Site submit About | Contacts | Directions Los Alamos National LaboratoryBradbury Science Museum Your Window into Los Alamos National Laboratory Bradbury Science Museum Menu About Contacts Directions Visit Visitor Information About the Museum Large Group Visits Around Los Alamos Contact Us

  19. Risk factors for contacts between wild boar and outdoor pigs in Switzerland and investigations on potential Brucella suis spill-over.

    PubMed

    Wu, Natacha; Abril, Carlos; Thomann, Andreas; Grosclaude, Eleonore; Doherr, Marcus G; Boujon, Patrick; Ryser-Degiorgis, Marie-Pierre

    2012-07-20

    Due to the parallel increase of the number of free-ranging wild boar and domestic pigs reared outdoor, the risk that they interact has become higher. Contacts with wild boar can be the origin of disease outbreaks in pigs, as it has been documented for brucellosis in some European countries. This study aimed at quantifying the occurrence of contacts between wild boar and outdoor domestic pigs in Switzerland, and identifying risk factors for these contacts. Furthermore, exposed pigs were tested for pathogen spill-over, taking Brucella suis as an example because B. suis is widespread in Swiss wild boar while domestic pigs are officially free of brucellosis. Thirty-one percent of the game-wardens and 25% of the pig owners participating to a country-wide questionnaire survey reported contacts, including approaches of wild boar outside the fence, intrusions, and mating. Seventeen piggeries (5%) reported the birth of cross-bred animals. Risk factors for contacts identified by a uni- and multivariable logistic regression approach were: distance between pig enclosure and buildings, proximity of a forest, electric fences, and fences ≤ 60 cm. Pigs of the Mangalitza breed were most at risk for mating with wild boar (births of cross-bred animals). Blood and tissues of 218 outdoor pigs from 13 piggeries were tested for an infection with Brucella suis, using rose bengal test, complement fixation test, and an IS711-based real-time PCR. One piggery with previous wild boar contacts was found infected with B. suis, however, epidemiological investigations failed to identify the direct source of infection. Results show that interactions between wild boar and outdoor pigs are not uncommon, pointing at the existing risk of pathogen spill-over. Provided data on risk factors for these interactions could help the risk-based implementation of protection measures for piggeries. The documentation of a brucellosis outbreak in pigs despite the freedom-of-disease status underlines the importance of improving pathogen surveillance strategies and increasing disease awareness of farmers and veterinary practitioners.

  20. Risk factors for contacts between wild boar and outdoor pigs in Switzerland and investigations on potential Brucella suis spill-over

    PubMed Central

    2012-01-01

    Background Due to the parallel increase of the number of free-ranging wild boar and domestic pigs reared outdoor, the risk that they interact has become higher. Contacts with wild boar can be the origin of disease outbreaks in pigs, as it has been documented for brucellosis in some European countries. This study aimed at quantifying the occurrence of contacts between wild boar and outdoor domestic pigs in Switzerland, and identifying risk factors for these contacts. Furthermore, exposed pigs were tested for pathogen spill-over, taking Brucella suis as an example because B. suis is widespread in Swiss wild boar while domestic pigs are officially free of brucellosis. Results Thirty-one percent of the game-wardens and 25% of the pig owners participating to a country-wide questionnaire survey reported contacts, including approaches of wild boar outside the fence, intrusions, and mating. Seventeen piggeries (5%) reported the birth of cross-bred animals. Risk factors for contacts identified by a uni- and multivariable logistic regression approach were: distance between pigs enclosure and houses, proximity of a forest, electric fences, and fences ≤ 60 cm. Pigs of the Mangalitza breed were most at risk for mating with wild boar (births of cross-bred animals). Blood and tissues of 218 outdoor pigs from 13 piggeries were tested for an infection with Brucella suis, using rose bengal test, complement fixation test, and an IS711-based real-time PCR. One piggery with previous wild boar contacts was found infected with B. suis, however, epidemiological investigations failed to identify the direct source of infection. Conclusions Results show that interactions between wild boar and outdoor pigs are not uncommon, pointing at the existing risk of pathogen spill-over. Provided data on risk factors for these interactions could help the risk-based implementation of protection measures for piggeries. The documentation of a brucellosis outbreak in pigs despite the freedom-of-disease status underlines the importance of improving pathogen surveillance strategies and increasing disease awareness of farmers and veterinary practitioners. PMID:22817843

  1. Approaches of health caregivers to young children in a pediatric intensive care unit.

    PubMed

    Orsuto, J; Corbo, B H

    1987-01-01

    This study explored the frequency of health caregiver approaches to 12 toddlers and preschool children in a pediatric intensive care unit. Using a time-sampling methodology, 3 hours of observation per child were obtained; half occurred between 7 A.M. and 7 P.M. and half were between 7 P.M. and 7 A.M.. Data were analyzed using descriptive statistics. Caregiver approaches involved either direct or indirect contact. Indirect contacts occurred three times more frequently than direct, with registered nurses initiating more contacts than any other caregivers. The greatest number of direct contacts were categorized as intrusive, while the least number were comforting contacts. The findings suggest that nurses are in optimal positions to promote rest and comforting contact for children in the pediatric intensive care unit.

  2. Subthalamic stimulation may inhibit the beneficial effects of levodopa on akinesia and gait.

    PubMed

    Fleury, Vanessa; Pollak, Pierre; Gere, Julien; Tommasi, Giorgio; Romito, Luigi; Combescure, Christophe; Bardinet, Eric; Chabardes, Stephan; Momjian, Shahan; Krainik, Alexandre; Burkhard, Pierre; Yelnik, Jérôme; Krack, Paul

    2016-09-01

    Gait and akinesia deterioration in PD patients during the immediate postoperative period of DBS has been directly related to stimulation in the subthalamic region. The underlying mechanisms remain poorly understood. The aim of the present study was to clinically and anatomically describe this side effect. PD patients presenting with a worsening of gait and/or akinesia following STN-DBS, that was reversible on stimulation arrest were included. The evaluation included (1) a Stand Walk Sit Test during a monopolar survey of each electrode in the on-drug condition; (2) a 5-condition test with the following conditions: off-drug/off-DBS, off-drug/on-best-compromise-DBS, on-drug/off-DBS, on-drug/on-best-compromise-DBS, and on-drug/on-worsening-DBS, which utilized the contact inducing the most prominent gait deterioration. The following scales were performed: UPDRSIII subscores, Stand Walk Sit Test, and dyskinesia and freezing of gait scales. Localization of contacts was performed using a coregistration method. Twelve of 17 patients underwent the complete evaluation. Stimulation of the most proximal contacts significantly slowed down the Stand Walk Sit Test. The on-drug/on-worsening-DBS condition compared with the on-drug/off-DBS condition worsened akinesia (P = 0.02), Stand Walk Sit Test (P = 0.001), freezing of gait (P = 0.02), and improved dyskinesias (P = 0.003). Compared with the off-drug/off-DBS condition, the on-drug/on-worsening-DBS condition improved rigidity (P = 0.007) and tremor (P = 0.007). Worsening contact sites were predominantly dorsal and anterior to the STN in the anterior zona incerta and Forel fields H2. A paradoxical deterioration of gait and akinesia is a rare side effect following STN-DBS. We propose that this may be related to misplaced contacts, and we discuss the pathophysiology and strategies to identify and manage this complication. © 2016 International Parkinson and Movement Disorder Society. © 2016 International Parkinson and Movement Disorder Society.

  3. Experimental study of tyre/road contact forces in rolling conditions for noise prediction

    NASA Astrophysics Data System (ADS)

    Cesbron, Julien; Anfosso-Lédée, Fabienne; Duhamel, Denis; Ping Yin, Hai; Le Houédec, Donatien

    2009-02-01

    This paper deals with the experimental study of dynamical tyre/road contact for noise prediction. In situ measurements of contact forces and close proximity noise levels were carried out for a slick tyre rolling on six different road surfaces between 30 and 50 km/h. Additional texture profiles of the tested surfaces were taken on the wheel track. Normal contact stresses were measured at a sampling frequency of 10752 Hz using a line of pressure sensitive cells placed both along and perpendicular to the rolling direction. The contact areas obtained during rolling were smaller than in static conditions. This is mainly explained by the dynamical properties of tyre compounds, like the viscoelastic behaviour of the rubber. Additionally the root-mean-square of the resultant contact forces at various speeds was in the same order for a given road surface, while their spectra were quite different. This is certainly due to a spectral influence of bending waves propagating in the tyre during rolling, especially when the wavelength is small in comparison with the size of the contact patch. Finally, the levels of contact forces and close proximity noise measured at 30 km/h were correlated. Additional correlations with texture levels were performed. The results show that the macro-texture generates contact forces linearly around 800 Hz and consequently noise levels between 500 and 1000 Hz via the vibrations transmitted to the tyre.

  4. From biofuels to predicting the flu

    Science.gov Websites

    Search Site submit About | Contacts | Directions Los Alamos National LaboratoryBradbury Science Museum Your Window into Los Alamos National Laboratory Bradbury Science Museum Menu About Contacts Directions Visit Visitor Information About the Museum Large Group Visits Around Los Alamos Contact Us

  5. Climate change and the Arctic

    Science.gov Websites

    Search Site submit About | Contacts | Directions Los Alamos National LaboratoryBradbury Science Museum Your Window into Los Alamos National Laboratory Bradbury Science Museum Menu About Contacts Directions Visit Visitor Information About the Museum Large Group Visits Around Los Alamos Contact Us

  6. Bacterial Pathogen Emergence Requires More than Direct Contact with a Novel Passerine Host

    PubMed Central

    Hill, Geoffrey E.; Josefson, Chloe C.; Armbruster, Jonathan W.

    2018-01-01

    ABSTRACT While direct contact may sometimes be sufficient to allow a pathogen to jump into a new host species, in other cases, fortuitously adaptive mutations that arise in the original donor host are also necessary. Viruses have been the focus of most host shift studies, so less is known about the importance of ecological versus evolutionary processes to successful bacterial host shifts. Here we tested whether direct contact with the novel host was sufficient to enable the mid-1990s jump of the bacterium Mycoplasma gallisepticum from domestic poultry to house finches (Haemorhous mexicanus). We experimentally inoculated house finches with two genetically distinct M. gallisepticum strains obtained either from poultry (Rlow) or from house finches (HF1995) during an epizootic outbreak. All 15 house finches inoculated with HF1995 became infected, whereas Rlow successfully infected 12 of 15 (80%) inoculated house finches. Comparisons among infected birds showed that, relative to HF1995, Rlow achieved substantially lower bacterial loads in the host respiratory mucosa and was cleared faster. Furthermore, Rlow-infected finches were less likely to develop clinical symptoms than HF1995-infected birds and, when they did, displayed milder conjunctivitis. The lower infection success of Rlow relative to HF1995 was not, however, due to a heightened host antibody response to Rlow. Taken together, our results indicate that contact between infected poultry and house finches was not, by itself, sufficient to explain the jump of M. gallisepticum to house finches. Instead, mutations arising in the original poultry host would have been necessary for successful pathogen emergence in the novel finch host. PMID:29311238

  7. Calibration of non-contact ultrasound as an online sensor for wood characterization: Effects of temperature, moisture, and scanning direction

    NASA Astrophysics Data System (ADS)

    Vun, R. Y.; Hoover, K.; Janowiak, J.; Bhardwaj, M.

    2008-01-01

    Numerous handheld moisture meters are available for measuring moisture levels of wood and building materials for a vast range of quality control and moisture diagnosis applications. However, many methods currently available require physical contact of a probe with the test material to operate. The contact requirement of such devices has limited applications for these purposes. There is a tremendous demand for dynamic online quality assessment of in-process materials for moisture content (MC) measurements. In this paper, a non-destructive non-contact ultrasound technology was used to evaluate the effects of increasing temperature in two MC levels and of increasing MC in lumber. The results show that the ultrasonic absolute transmittance and velocity parameters are directly correlated very well (R2≥0.87) with temperature for the two moisture levels in wood. At constant temperature, however, the velocity is inversely correlated with MC. It was also found that the distribution of MC along the length is marginally insignificant to both ultrasonic measurements. The transmittance measurement along the orthogonal thickness direction is insignificant above the fiber saturation MC; similarly, the velocity measurement is marginally insignificant. The study concludes a positive correlation and a good fit for this technology to advance into the development of an automated device for determining wood moisture levels, which will in turn be used to control the dynamics of wood drying/sterilization processes. Further calibration research is recommended to ascertain the constraints and limitations of the technology to specific wood species and dimension.

  8. A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury

    PubMed Central

    Jiang, JingLe; Marathe, Amar R.; Keene, Jennifer C.; Taylor, Dawn M.

    2016-01-01

    Background Custom-fitted skull replacement pieces are often used after a head injury or surgery to replace damaged bone. Chronic brain recordings are beneficial after injury/surgery for monitoring brain health and seizure development. Embedding electrodes directly in these artificial skull replacement pieces would be a novel, low-risk way to perform chronic brain monitoring in these patients. Similarly, embedding electrodes directly in healthy skull would be a viable minimally-invasive option for many other neuroscience and neurotechnology applications requiring chronic brain recordings. New Method We demonstrate a preclinical testbed that can be used for refining electrode designs embedded in artificial skull replacement pieces or for embedding directly into the skull itself. Options are explored to increase the surface area of the contacts without increasing recording contact diameter to maximize recording resolution. Results Embedding electrodes in real or artificial skull allows one to lower electrode impedance without increasing the recording contact diameter by making use of conductive channels that extend into the skull. The higher density of small contacts embedded in the artificial skull in this testbed enables one to optimize electrode spacing for use in real bone. Comparison with Existing Methods For brain monitoring applications, skull-embedded electrodes fill a gap between electroencephalograms recorded on the scalp surface and the more invasive epidural or subdural electrode sheets. Conclusions Embedding electrodes into the skull or in skull replacement pieces may provide a safe, convenient, minimally-invasive alternative for chronic brain monitoring. The manufacturing methods described here will facilitate further testing of skull-embedded electrodes in animal models. PMID:27979758

  9. A testbed for optimizing electrodes embedded in the skull or in artificial skull replacement pieces used after injury.

    PubMed

    Jiang, JingLe; Marathe, Amar R; Keene, Jennifer C; Taylor, Dawn M

    2017-02-01

    Custom-fitted skull replacement pieces are often used after a head injury or surgery to replace damaged bone. Chronic brain recordings are beneficial after injury/surgery for monitoring brain health and seizure development. Embedding electrodes directly in these artificial skull replacement pieces would be a novel, low-risk way to perform chronic brain monitoring in these patients. Similarly, embedding electrodes directly in healthy skull would be a viable minimally-invasive option for many other neuroscience and neurotechnology applications requiring chronic brain recordings. We demonstrate a preclinical testbed that can be used for refining electrode designs embedded in artificial skull replacement pieces or for embedding directly into the skull itself. Options are explored to increase the surface area of the contacts without increasing recording contact diameter to maximize recording resolution. Embedding electrodes in real or artificial skull allows one to lower electrode impedance without increasing the recording contact diameter by making use of conductive channels that extend into the skull. The higher density of small contacts embedded in the artificial skull in this testbed enables one to optimize electrode spacing for use in real bone. For brain monitoring applications, skull-embedded electrodes fill a gap between electroencephalograms recorded on the scalp surface and the more invasive epidural or subdural electrode sheets. Embedding electrodes into the skull or in skull replacement pieces may provide a safe, convenient, minimally-invasive alternative for chronic brain monitoring. The manufacturing methods described here will facilitate further testing of skull-embedded electrodes in animal models. Published by Elsevier B.V.

  10. Vagal innervation of the aldosterone-sensitive HSD2 neurons in the NTS

    PubMed Central

    Shin, Jung-Won; Geerling, Joel C.; Loewy, Arthur D.

    2009-01-01

    The nucleus of the solitary tract (NTS) contains a unique subpopulation of aldosterone-sensitive neurons. These neurons express the enzyme 11-β-hydroxysteroid dehydrogenase type 2 (HSD2) and are activated by sodium deprivation. They are located in the caudal NTS, a region which is densely innervated by the vagus nerve, suggesting that they could receive direct viscerosensory input from the periphery. To test this possibility, we injected the highly sensitive axonal tracer biotinylated dextran amine (BDA) into the left nodose ganglion in rats. Using confocal microscopy, we observed a sparse input from the vagus to most HSD2 neurons. Roughly 80% of the ipsilateral HSD2 neurons exhibited at least one close contact with a BDA-labeled vagal bouton, although most of these cells received only a few total contacts. Most of these contacts were axo-dendritic (~80%), while ~20% were axo-somatic. In contrast, the synaptic vesicular transporters VGLUT2 or GAD7 labeled much larger populations of boutons contacting HSD2-labeled dendrites and somata, suggesting that direct input from the vagus may only account for a minority of the information integrated by these neurons. In summary, the aldosterone-sensitive HSD2 neurons in the NTS appear to receive a small amount of direct viscerosensory input from the vagus nerve. The peripheral sites of origin and functional significance of this projection remain unknown. Combined with previously-identified central sources of input to these cells, the present finding indicates that the HSD2 neurons integrate humoral information with input from a variety of neural afferents. PMID:19010311

  11. Transmissibility and Pathogenicity of Ebola Virus: A Systematic Review and Meta-analysis of Household Secondary Attack Rate and Asymptomatic Infection

    PubMed Central

    Dean, Natalie E.; Halloran, M. Elizabeth; Yang, Yang; Longini, Ira M.

    2016-01-01

    Factors affecting our ability to control an Ebola outbreak include transmissibility of the virus and the proportion of transmissions occurring asymptomatically. We performed a meta-analysis of Ebola household secondary attack rate (SAR), disaggregating by type of exposure (direct contact, no direct contact, nursing care, direct contact but no nursing care). The estimated overall household SAR is 12.5% (95% confidence interval [CI], 8.6%–16.3%). Transmission was driven by direct contact, with little transmission occurring in its absence (SAR, 0.8% [95% CI, 0%–2.3%]). The greatest risk factor was the provision of nursing care (SAR, 47.9% [95% CI, 23.3%–72.6%]). There was evidence of a decline in household SAR for direct contact between 1976 and 2014 (P = .018). We estimate that 27.1% (95% CI, 14.5%–39.6%) of Ebola infections are asymptomatic. Our findings suggest that surveillance and containment measures should be effective for controlling Ebola. PMID:26932131

  12. 75 FR 12466 - Airworthiness Directives; GROB-WERKE (Type Certificate Previously Held by BURKHART GROB Luft- und...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-03-16

    ... failed canopy jettison test, during a regular maintenance check. The investigation revealed that a cable... received by the closing date and may amend this proposed AD because of those comments. We will post all... provide. We will also post a report summarizing each substantive verbal contact we receive about this...

  13. 75 FR 43095 - Airworthiness Directives; PIAGGIO AERO INDUSTRIES S.p.A. Model PIAGGIO P-180 Airplanes

    Federal Register 2010, 2011, 2012, 2013, 2014

    2010-07-23

    ... subsequent corrosion, can cause incorrect reading of the engine oil low level on the Refuel/Ground Test Panel... date and may amend this proposed AD because of those comments. We will post all comments we receive... also post a report summarizing each substantive verbal contact we receive about this proposed AD...

  14. Potential heat exchange fluids for use in sulfuric acid vaporizers

    NASA Technical Reports Server (NTRS)

    Lawson, D. D.; Petersen, G. R.

    1979-01-01

    A series of perhalocarbons are proposed as candidate heat exchange fluids for service in thermochemical cycles for hydrogen production that involve direct contact of the fluid with sulfuric acid and vaporization of the acid. The required chemical and physical criteria of the liquids are described and the results of some preliminary high temperature test data are presented.

  15. 77 FR 72203 - Airworthiness Directives; Lycoming Engines and Continental Motors, Inc. Reciprocating Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-05

    ... CFR 39.19 to make your request. (h) Related Information For more information about this AD, contact... August 29, 2012. This AD requires removing the affected turbochargers from service before further flight. This AD was prompted by a report of a turbocharger turbine wheel that failed a static strength test at...

  16. 10 CFR 32.53 - Luminous safety devices for use in aircraft: Requirements for license to manufacture, assemble...

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ... maximum quantity of tritium or promethium-147 in each device; (2) Details of construction and design; (3... information, including experimental studies and tests, required by the Commission to facilitate a... direct physical contact by any person with it; (3) The device is so designed that it cannot easily be...

  17. 10 CFR 32.53 - Luminous safety devices for use in aircraft: Requirements for license to manufacture, assemble...

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ... maximum quantity of tritium or promethium-147 in each device; (2) Details of construction and design; (3... information, including experimental studies and tests, required by the Commission to facilitate a... direct physical contact by any person with it; (3) The device is so designed that it cannot easily be...

  18. Susceptibility of Tribolium castaneum and Trogoderma variabile larvae and adults exposed to methoprene-treated woven packaing material

    USDA-ARS?s Scientific Manuscript database

    Methoprene is an insect growth regulator (IGR) registered in the United States for direct application to stored raw grains, as an aerosol or residual contact insecticide, or for use as a packaging treatment for protection of bagged processed food products. A series of tests were conducted to determi...

  19. A collision model for grain-resolving simulations of flows over dense, mobile, polydisperse granular sediment beds

    DOE PAGES

    Biegert, Edward; Vowinckel, Bernhard; Meiburg, Eckart

    2017-03-21

    We present a collision model for phase-resolved Direct Numerical Simulations of sediment transport that couple the fluid and particles by the Immersed Boundary Method. Typically, a contact model for these types of simulations comprises a lubrication force for particles in close proximity to another solid object, a normal contact force to prevent particles from overlapping, and a tangential contact force to account for friction. Our model extends the work of previous authors to improve upon the time integration scheme to obtain consistent results for particle-wall collisions. Furthermore, we account for polydisperse spherical particles and introduce new criteria to account formore » enduring contact, which occurs in many sediment transport situations. This is done without using arbitrary values for physically-defined parameters and by maintaining the full momentum balance of a particle in enduring contact. Lastly, we validate our model against several test cases for binary particle-wall collisions as well as the collective motion of a sediment bed sheared by a viscous flow, yielding satisfactory agreement with experimental data by various authors.« less

  20. A collision model for grain-resolving simulations of flows over dense, mobile, polydisperse granular sediment beds

    NASA Astrophysics Data System (ADS)

    Biegert, Edward; Vowinckel, Bernhard; Meiburg, Eckart

    2017-07-01

    We present a collision model for phase-resolved Direct Numerical Simulations of sediment transport that couple the fluid and particles by the Immersed Boundary Method. Typically, a contact model for these types of simulations comprises a lubrication force for particles in close proximity to another solid object, a normal contact force to prevent particles from overlapping, and a tangential contact force to account for friction. Our model extends the work of previous authors to improve upon the time integration scheme to obtain consistent results for particle-wall collisions. Furthermore, we account for polydisperse spherical particles and introduce new criteria to account for enduring contact, which occurs in many sediment transport situations. This is done without using arbitrary values for physically-defined parameters and by maintaining the full momentum balance of a particle in enduring contact. We validate our model against several test cases for binary particle-wall collisions as well as the collective motion of a sediment bed sheared by a viscous flow, yielding satisfactory agreement with experimental data by various authors.

  1. Convective heat transfer measurements in a vapour-liquid-liquid three-phase direct contact heat exchanger

    NASA Astrophysics Data System (ADS)

    Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.

    2018-06-01

    Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.

  2. Convective heat transfer measurements in a vapour-liquid-liquid three-phase direct contact heat exchanger

    NASA Astrophysics Data System (ADS)

    Mahood, Hameed B.; Campbell, A. N.; Baqir, Ali Sh.; Sharif, A. O.; Thorpe, R. B.

    2017-12-01

    Energy usage is increasing around the world due to the continued development of technology, and population growth. Solar energy is a promising low-grade energy resource that can be harvested and utilised in different applications, such solar heater systems, which are used in both domestic and industrial settings. However, the implementation of an efficient energy conversion system or heat exchanger would enhance such low-grade energy processes. The direct contact heat exchanger could be the right choice due to its ability to efficiently transfer significant amounts of heat, simple design, and low cost. In this work, the heat transfer associated with the direct contact condensation of pentane vapour bubbles in a three-phase direct contact condenser is investigated experimentally. Such a condenser could be used in a cycle with a solar water heater and heat recovery systems. The experiments on the steady state operation of the three-phase direct contact condenser were carried out using a short Perspex tube of 70 cm in total height and an internal diameter of 4 cm. Only a height of 48 cm was active as the direct contact condenser. Pentane vapour, (the dispersed phase) with three different initial temperatures (40° C, 43.5° C and 47.5° C) was directly contacted with water (the continuous phase) at 19° C. The experimental results showed that the total heat transfer rate per unit volume along the direct contact condenser gradually decreased upon moving higher up the condenser. Additionally, the heat transfer rate increases with increasing mass flow rate ratio, but no significant effect on the heat transfer rate of varying the initial temperature of the dispersed phase was seen. Furthermore, both the outlet temperature of the continuous phase and the void fraction were positively correlated with the total heat transfer rate per unit volume, with no considerable effect of the initial temperature difference between the dispersed and continuous phases.

  3. Binding Direction-Based Two-Dimensional Flattened Contact Area Computing Algorithm for Protein-Protein Interactions.

    PubMed

    Kang, Beom Sik; Pugalendhi, GaneshKumar; Kim, Ku-Jin

    2017-10-13

    Interactions between protein molecules are essential for the assembly, function, and regulation of proteins. The contact region between two protein molecules in a protein complex is usually complementary in shape for both molecules and the area of the contact region can be used to estimate the binding strength between two molecules. Although the area is a value calculated from the three-dimensional surface, it cannot represent the three-dimensional shape of the surface. Therefore, we propose an original concept of two-dimensional contact area which provides further information such as the ruggedness of the contact region. We present a novel algorithm for calculating the binding direction between two molecules in a protein complex, and then suggest a method to compute the two-dimensional flattened area of the contact region between two molecules based on the binding direction.

  4. Sputter-deposited WO x and MoO x for hole selective contacts

    DOE PAGES

    Bivour, Martin; Zähringer, Florian; Ndione, Paul F.; ...

    2017-09-21

    Here, reactive sputter deposited tungsten and molybdenum oxide (WO x, MoO x) thin films are tested for their ability to form a hole selective contact for Si wafer based solar cells. A characterization approach based on analyzing the band bending induced in the c-Si absorber and the external and implied open-circuit voltage of test structures was used. It is shown that the oxygen partial pressure allows to tailor the selectivity to some extent and that a direct correlation between induced band bending and hole selectivity exists. Although the selectivity of the sputtered films is inferior to the reference films depositedmore » by thermal evaporation, these results demonstrate a good starting point for further optimizations of sputtered WO x and MoO x towards higher work functions to improve the hole selectivity.« less

  5. Sputter-deposited WO x and MoO x for hole selective contacts

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bivour, Martin; Zähringer, Florian; Ndione, Paul F.

    Here, reactive sputter deposited tungsten and molybdenum oxide (WO x, MoO x) thin films are tested for their ability to form a hole selective contact for Si wafer based solar cells. A characterization approach based on analyzing the band bending induced in the c-Si absorber and the external and implied open-circuit voltage of test structures was used. It is shown that the oxygen partial pressure allows to tailor the selectivity to some extent and that a direct correlation between induced band bending and hole selectivity exists. Although the selectivity of the sputtered films is inferior to the reference films depositedmore » by thermal evaporation, these results demonstrate a good starting point for further optimizations of sputtered WO x and MoO x towards higher work functions to improve the hole selectivity.« less

  6. Taking care of suicidal patients with new technologies and reaching-out means in the post-discharge period

    PubMed Central

    Falcone, Giulia; Nardella, Adele; Lamis, Dorian A; Erbuto, Denise; Girardi, Paolo; Pompili, Maurizio

    2017-01-01

    Suicide is a global public health problem with over one million people dying by suicide each year worldwide. Research efforts have focused on developing and testing novel suicide prevention strategies employing recent technological advances. In order to provide a review regarding the role of new technologies (e.g., postcards/letters, text messages, crisis cards, telephone contacts, online interventions) in suicide prevention, we searched PubMed, ScienceDirect, ResearchGate, and Crisis to identify all papers in English from 1977 to 2016. Our results indicated that brief contact interventions show promise in reducing the number of episodes of repeated self-harm and/or suicide attempts following discharge from the Emergency Department or psychiatric units. Innovative methods of contact (e.g., text messages) are easily implemented by clinicians and received by patients in the period of post discharge and have been shown to be beneficial. However, more research employing randomized clinical trials investigating the potential benefits of these novel suicide prevention methods is warranted. Future researchers should continue improving and testing new technologies in the prevention of suicide. PMID:29043154

  7. Eye Contact Facilitates Awareness of Faces during Interocular Suppression

    ERIC Educational Resources Information Center

    Stein, Timo; Senju, Atsushi; Peelen, Marius V.; Sterzer, Philipp

    2011-01-01

    Eye contact captures attention and receives prioritized visual processing. Here we asked whether eye contact might be processed outside conscious awareness. Faces with direct and averted gaze were rendered invisible using interocular suppression. In two experiments we found that faces with direct gaze overcame such suppression more rapidly than…

  8. Early Left Parietal Activity Elicited by Direct Gaze: A High-Density EEG Study

    PubMed Central

    Burra, Nicolas; Kerzel, Dirk; George, Nathalie

    2016-01-01

    Gaze is one of the most important cues for human communication and social interaction. In particular, gaze contact is the most primary form of social contact and it is thought to capture attention. A very early-differentiated brain response to direct versus averted gaze has been hypothesized. Here, we used high-density electroencephalography to test this hypothesis. Topographical analysis allowed us to uncover a very early topographic modulation (40–80 ms) of event-related responses to faces with direct as compared to averted gaze. This modulation was obtained only in the condition where intact broadband faces–as opposed to high-pass or low-pas filtered faces–were presented. Source estimation indicated that this early modulation involved the posterior parietal region, encompassing the left precuneus and inferior parietal lobule. This supports the idea that it reflected an early orienting response to direct versus averted gaze. Accordingly, in a follow-up behavioural experiment, we found faster response times to the direct gaze than to the averted gaze broadband faces. In addition, classical evoked potential analysis showed that the N170 peak amplitude was larger for averted gaze than for direct gaze. Taken together, these results suggest that direct gaze may be detected at a very early processing stage, involving a parallel route to the ventral occipito-temporal route of face perceptual analysis. PMID:27880776

  9. Elastic model of the traction behavior of two traction lubricants

    NASA Technical Reports Server (NTRS)

    Loewenthal, S. H.; Rohn, D. A.

    1984-01-01

    In the analysis of rolling-sliding concentrated contacts, such as gears, bearings and traction drives, the traction characteristics of the lubricant are of prime importance. The elastic shear modulus and limiting shear stress properties of the lubricant dictate the traction/slip characteristics and power loss associated with an EHD contact undergoing slip and/or spin. These properties can be deducted directly from the initial slope m and maximum traction coefficient micron of an experimental traction curve. In this investigation, correlation equations are presented to predict m and micron for two modern traction fluids based on the regression analysis of 334 separate traction disk machine experiments. The effects of contact pressure, temperature, surface velocity, ellipticity ratio are examined. Problems in deducing lubricant shear moduli from disk machine tests are discussed. Previously announced in STAR as N83-20116

  10. Contact characteristics of the subtalar joint after a simulated calcaneus fracture.

    PubMed

    Sangeorzan, B J; Ananthakrishnan, D; Tencer, A F

    1995-06-01

    A simple calcaneus fracture consisting of two parts was modeled in nine fresh cadaver hindfoot specimens to assess changes in subtalar joint contact characteristics with increasing plantar depression of the posterolateral fracture component. To perform the experiment, rods were placed in the tibial and fibular shafts of each specimen, which was mounted in a frame in neutral stance. A pneumatic cylinder was used to deliver a vertical compressive load through the rods into the foot while permitting free motion of the foot in the horizontal plane. Sealed packets of pressure-sensitive film were inserted into the anterior-middle and posterior facets of the talocalcaneal articulation, and a 700-N load was applied. After testing of the intact foot, a primary fracture line was created using a microoscillating saw. The osteotomized posterolateral component was anatomically reduced and fixed, the film inserted, and the load reapplied. The test was repeated after the posterolateral fragment was displaced 2, 5, and 10 mm in a plantar direction. The resulting pressure prints were scanned along with pressure/color density calibration strips using a flat-bed scanner, and an image analysis system was used to determine contact areas within specified pressure intervals. The contact area (> 0.5 MPa) of the posterior facet was significantly decreased with 2, 5, and 10 mm displacements of the posterolateral calcaneus fracture component. The ratio of high-pressure area (< 5.0 MPa) to contact area in the posterior facet was significantly increased only with displacements of 5 and 10 mm. There were no significant changes in any contact parameters in the anterior-middle facet.(ABSTRACT TRUNCATED AT 250 WORDS)

  11. Bi-directional transmission of molecular information by photon or electron beams passing in the close vicinity of specific molecules, and its clinical and basic research applications: 1) Diagnosis of humans or animal patients without any direct contact; 2) Light microscopic and electron microscopic localization of neuro-transmitters, heavy metals, Oncogen C-fos (AB2), etc. of intracellular fine structures of normal and abnormal single cells using light or electro-microscopic indirect Bi-Digital O-Ring Test.

    PubMed

    Omura, Y; Losco, M; Omura, A K; Takeshige, C; Hisamitsu, T; Nakajima, H; Soejima, K; Yamamoto, S; Ishikawa, H; Kagoshima, T

    1992-01-01

    In 1985, Omura, Y. discovered that, when specific molecules were placed anywhere in the close vicinity of the path of a light beam (laser), their molecular information, as well as information on electrical & magnetic fields, is transmitted bi-directionally along the path of this light beam. Namely, this information is transmitted in the direction the light beam is projected and towards the direction from which the light beam is coming. This finding was applied to the following clinical and basic research: 1) In the past, using indirect Bi-Digital O-Ring Test, human or animal patients were diagnosed through an intermediate third person holding a good electrical conducting probe, the tip of which was touching the part of the patient to be examined. However, in order to diagnose the patient in isolation from a distance, or a dangerous or unmanagable unanesthesized animal, such as a lion or tiger, the author succeeded in making a diagnosis by replacing the metal conducting probe with a soft laser beam which is held by the one hand of the third person whose index finger is placed in close vicinity of the laser beam generated by a battery-powered penlight-type solid state laser generator. Thus, diagnosis within visible distance, without direct patient contact, became a reality. 2) Using a projection light microscope, by giving indirect Bi-Digital O-Ring Test while contacting with a fine electro-conductive probe on the magnified fine structure of normal and abnormal cells, various normal and abnormal intracellular substances were localized through a third person holding a pure reference control substance with the same hand that is holding the probe as an intermediary for the indirect Bi-Digital O-Ring Test. Instead of the photon beam in a light microscope, the author found that, using an electron beam passing through the close vicinity of specific molecules of specimens in an electron microscope, the molecular information is transmitted to the magnified fluorescent screen, and an indirect Bi-Digital O-Ring Test could be performed through a projected penlight-type solid state soft laser beam on the magnified intracellular structure through an observation glass window. Using the magnified fine structure of the cells, by either a light projection microscopic field or electron microscope, in various cancer cells of both humans and animals, Oncogen C-fos (AB2) and mercury were found inside of the nucleus. Integrin alpha 5 beta 1 was found on cell membranes and nuclear cell membranes of cancer cells. Acetylcholine was not found anywhere within cancer cells.(ABSTRACT TRUNCATED AT 400 WORDS)

  12. Membrane Vibration Studies Using a Scanning Laser Vibrometer

    NASA Technical Reports Server (NTRS)

    Gaspar, James L.; Solter, Micah J.; Pappa, Richard S.

    2001-01-01

    This paper summarizes on-going experimental work at NASA Langley Research Center to measure the dynamics of a 1.016 m (40 in.) square polyimide film Kapton membrane. A fixed fully automated impact hammer and Polytec PSV-300-H scanning laser vibrometer were used for non-contact modal testing of the membrane with zero-mass-loading. The paper discusses the results obtained by testing the membrane at various tension levels and at various excitation locations. Results obtained by direct shaker excitation to the membrane are also discussed.

  13. Task Order Number 5TS5702D035P: Testing Alternative Aircraft and Runway/Taxiway Deicers - Phase 2

    DTIC Science & Technology

    2004-06-01

    represent the worst-case scenarios. In actual circumstances, due to location on the aircraft, many of these materials would be protected from direct contact...application and its location . This report is not intended to make judgments on the suitability of any of the products tested. It contains only data and a...table, in order to determine the significance of the difference in the data. The raw laboratory data are located in Appendix B. Table 9. Polymer Matrix

  14. Cytotoxicity Evaluation of Self Adhesive Composite Resin Cements by Dentin Barrier Test on 3D Pulp Cells.

    PubMed

    Ulker, Hayriye Esra; Sengun, Abdulkadir

    2009-04-01

    The aim of this study was to evaluate the effects of five self-etch dental composite resin cements on the cell viability of bovine dental papilla-derived cells. The cytotoxicity of composite resin cements (Rely X Unicem Clicker, 3M ESPE; MaxCem; KERR, Panavia F 2.0; Kuraray, BisCem; Bisco and Bistite II DC; Tokuyama) was analyzed in a dentin barrier test device using three-dimensional (3D) pulp cell cultures. A commercially available cell culture perfusion chamber was separated into two compartments by 500 mum dentin disc. The three dimensional cultures placed on a dentin disk held in place by a special biocompatible stainless-steel holder. Test materials were introduced into the upper compartment in direct contact with the cavity side of the dentin disks according to the manufacturer's instructions. Subsequently, the pulpal part of the perfusion chamber containing the cell cultures was perfused with medium (2 ml/h). After an exposure period of 24 h, the cell survival was determined by the MTT assay. Statistical analyses were performed using the Mann-Whitney U-test. In dentin barrier test, cell survival was similar with Maxcem and negative control group (P>.05), and all other tested materials were cytotoxic for the three dimensional cell cultures (P>.05). The significance of composite resin cements is being more important in dentistry. The cytotoxic potencies demonstrated by these materials might be of clinical relevance. Some composite resin cements include biologically active ingredients and may modify pulp cell metabolism when the materials are used in deep cavities or directly contact pulp tissue.

  15. Mechanical Properties Experimental Study of Engineering Vehicle Refurbished Tire

    NASA Astrophysics Data System (ADS)

    Qiang, Wang; Xiaojie, Qi; Zhao, Yang; Yunlong, Wang; Guotian, Wang; Degang, Lv

    2018-05-01

    The vehicle refurbished tire test system was constructed, got load-deformation, load-stiffness, and load-compression ratio property laws of engineering vehicle refurbished tire under the working condition of static state and ground contact, and built radial direction loading deformation mathematics model of 26.5R25 engineering vehicle refurbished tire. The test results show that radial-direction and side-direction deformation value is a little less than that of the new tire. The radial-direction stiffness and compression ratio of engineering vehicle refurbished tire were greatly influenced by radial-direction load and air inflation pressure. When load was certain, radial-direction stiffness would increase with air inflation pressure increasing. When air inflation pressure was certain, compression ratio of engineering vehicle refurbished tire would enlarge with radial-direction load increasing, which was a little less than that of the new and the same type tire. Aging degree of old car-case would exert a great influence on deformation property of engineering vehicle refurbished tire, thus engineering vehicle refurbished tires are suitable to the working condition of low tire pressure and less load.

  16. Exposure to stallion accelerates the onset of mares' cyclicity.

    PubMed

    Wespi, B; Sieme, H; Wedekind, C; Burger, D

    2014-07-15

    Horses (Equus caballus) belong to the group of seasonally polyestrous mammals. Estrous cycles typically start with increasing daylight length after winter, but mares can differ greatly in the timing of onset of regular estrus cycles. Here, we test whether spatial proximity to a stallion also plays a role. Twenty-two anestrous mares were either exposed to one of two stallions (without direct physical contact) or not exposed (controls) under experimental conditions during two consecutive springs (February to April). Ovarian activity was monitored via transrectal ultrasound and stallion's direct contact time with each mare was determined three times per week for one hour each. We found that mares exposed to a stallion ovulated earlier and more often during the observational period than mares that were not exposed to stallions. Neither stallion identity nor direct contact time, mare age, body condition, size of her largest follicle at the onset of the experiment, or parasite burden significantly affected the onset of cyclicity. In conclusion, the timing of estrous cycles and cycle frequency, i.e., crucial aspects of female reproductive strategy, strongly depend on how the mares perceive their social environment. Exposing mares to the proximity of a stallion can therefore be an alternative to, for example, light programs or elaborated hormonal therapies to start the breeding season earlier and increase the number of estrous cycles in horses. Copyright © 2014 Elsevier Inc. All rights reserved.

  17. An effect-directed strategy for characterizing emerging chemicals in food contact materials made from paper and board.

    PubMed

    Rosenmai, Anna Kjerstine; Bengtström, Linda; Taxvig, Camilla; Trier, Xenia; Petersen, Jens Højslev; Svingen, Terje; Binderup, Mona-Lise; Barbara Medea Alice, van Vugt-Lussenburg; Dybdahl, Marianne; Granby, Kit; Vinggaard, Anne Marie

    2017-08-01

    Food contact materials (FCM) are any type of item intended to come into contact with foods and thus represent a potential source for human exposure to chemicals. Regarding FCMs made of paper and board, information pertaining to their chemical constituents and the potential impacts on human health remains scarce, which hampers safety evaluation. We describe an effect-directed strategy to identify and characterize emerging chemicals in paper and board FCMs. Twenty FCMs were tested in eight reporter gene assays, including assays for the AR, ER, AhR, PPARγ, Nrf2 and p53, as well as mutagenicity. All FCMs exhibited activities in at least one assay. As proof-of-principle, FCM samples obtained from a sandwich wrapper and a pizza box were carried through a complete step-by-step multi-tiered approach. The pizza box exhibited ER activity, likely caused by the presence of bisphenol A, dibutyl phthalate, and benzylbutyl phthalate. The sandwich wrapper exhibited AR antagonism, likely caused by abietic acid and dehydroabietic acid. Migration studies confirmed that the active chemicals can transfer from FCMs to food simulants. In conclusion, we report an effect-directed strategy that can identify hazards posed by FCMs made from paper and board, including the identification of the chemical(s) responsible for the observed activity. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  18. A Psittacosis Outbreak among English Office Workers with Little or No Contact with Birds, August 2015.

    PubMed

    Mair-Jenkins, John; Lamming, Tracey; Dziadosz, Andy; Flecknoe, Daniel; Stubington, Thomas; Mentasti, Massimo; Muir, Peter; Monk, Philip

    2018-04-27

    On 14th August 2015 an office manager informed Public Health England of five employees known to have been diagnosed with pneumonia over the previous three weeks. We investigated to establish whether an outbreak occurred and to identify and control the source of infection. We undertook case finding for self-reported pneumonia cases at local businesses (July-August 2015). Clinical samples from a hospitalised case were tested for common respiratory pathogens, but returned negative results. Further testing confirmed Chlamydia psittaci infection in this case (serology and PCR).  We subsequently undertook C. psittaci testing for all cases, redefining them as confirmed ( C. psittaci PCR or high antibody titre via serology) or probable (inconclusive C. psittaci serology). Twenty-eight day exposure histories informed descriptive epidemiological analysis. We conducted an environmental investigation at the office to identify potential sources of exposure. We identified six office workers with pneumonia; four met case definitions (three confirmed, one probable) with symptom onset between 29th July and 4th August 2015. Workplace was the only epidemiological link and only one case reported limited, indirect bird contact. Environmental investigations identified pigeons roosting near the office which were being fed by workers (none cases). This was a probable outbreak of psittacosis with no direct bird-to-human contact reported. Cases recovered after receiving appropriate antibiotics. Feeding of pigeons was stopped. A deep clean of office ventilation systems was conducted and workers were advised to avoid bird contact.  We hypothesised that indirect environmental exposure to infected pigeons was to the source of this outbreak. This work provides evidence that health professionals should consider psittacosis in the differential diagnosis of cases of severe or atypical respiratory illness even without overt bird contact.

  19. New LMI based gain-scheduling control for recovering contact-free operation of a magnetically levitated rotor

    NASA Astrophysics Data System (ADS)

    Wang, M.; Cole, M. O. T.; Keogh, P. S.

    2017-11-01

    A new approach for the recovery of contact-free levitation of a rotor supported by active magnetic bearings (AMB) is assessed through control strategy design, system modelling and experimental verification. The rotor is considered to make contact with a touchdown bearing (TDB), which may lead to entrapment in a bi-stable nonlinear response. A linear matrix inequality (LMI) based gain-scheduling H∞ control technique is introduced to recover the rotor to a contact-free state. The controller formulation involves a time-varying effective stiffness parameter, which can be evaluated in terms of forces transmitted through the TDB. Rather than measuring these forces directly, an observer is introduced with a model of the base structure to transform base acceleration signals using polytopic coordinates for controller adjustment. Force transmission to the supporting base structure will occur either through an AMB alone without contact, or through the AMB and TDB with contact and this must be accounted for in the observer design. The controller is verified experimentally in terms of (a) non-contact robust stability and vibration suppression performance; (b) control action for contact-free recovery at typical running speeds with various unbalance and TDB misalignment conditions; and (c) coast-down experimental tests. The results demonstrate the effectiveness of the AMB control action whenever it operates within its dynamic load capacity.

  20. Understanding interprofessional relationships by the use of contact theory.

    PubMed

    Mohaupt, Jennifer; van Soeren, Mary; Andrusyszyn, Mary-Anne; Macmillan, Kathleen; Devlin-Cop, Sandra; Reeves, Scott

    2012-09-01

    The importance and necessity of interprofessional collaboration (IPC) present challenges for educators as they determine how best to achieve IPC through interprofessional education (IPE). Simulation-based teaching has been shown to enhance students' understanding of professional roles and promote positive attitudes toward team members; yet, empirical evidence providing direction on the conditions necessary to promote these positive outcomes is lacking. This study used a quasi-experimental design with a pre-/post-test to examine changes in undergraduate healthcare students' perceptions and attitudes toward IPC following their participation in an interprofessional simulation program. Allport's (1954) intergroup contact theory was used to help understand the nature of this IPE workshop and its reported outcomes. Participants included students in the final year of their respective programs (n = 84) such as pharmacy technician, paramedic, nursing and occupational therapy assistant/physical therapy assistant programs. These students were engaged in simulation exercises with interactive contact opportunities. Using the interdisciplinary education perceptions scale, statistically significant increases in positive attitudes in three of four sub-scales were found. An analysis of the structure and format of the workshop suggests that this IPE initiative fulfilled the key conditions suggested by intergroup contact theory. Attention to the key conditions provided by Allport's theory in the context of successful intergroup relationships may help provide direction for educators interested in planning IPE initiatives with student groups enrolled in various health programs.

  1. Contact angle control of sessile drops on a tensioned web

    NASA Astrophysics Data System (ADS)

    Park, Janghoon; Kim, Dongguk; Lee, Changwoo

    2018-04-01

    In this study, the influence of the change of tension applied to flexible and thin web substrate on the contact angle of sessile drop in roll-to-roll system was investigated. Graphene oxide and deionized water solutions were used in the experiments. Tension was changed to 29, 49, and 69 N, and the casting distance of the micropipette and the material was set to 10, 20, and 40 mm, and the droplet volume was set to 10, 20, and 30 μL, respectively. Statistical analysis of three variables and analysis of the variance methodology showed that the casting distance was most significant for the contact angle change, and the most interesting tension variable was also affected. The change in tension caused the maximum contact angle to change by 5.5°. The tension was not uniform in the width direction. When the droplet was applied in the same direction in the width direction, it was confirmed that the tension unevenness had great influence on the contact angle up to 11°. Finally, the casting distance, which has a large effect on the contact angle, was calibrated in the width direction to reduce the width direction contact angle deviation to 1%. This study can be applied to fine patterning research using continuous inkjet printing and aerosol jet printing, which are roll-to-roll processes based on droplet handling.

  2. Wettability and impact dynamics of water droplets on rice ( Oryza sativa L.) leaves

    NASA Astrophysics Data System (ADS)

    Kwon, Dae Hee; Huh, Hyung Kyu; Lee, Sang Joon

    2014-03-01

    We investigated the wettability and impact dynamics of water droplets on rice leaves at various leaf inclination angles and orientations. Contact angle, contact angle hysteresis (CAH), and roll-off angle ( α roll) of water droplets were measured quantitatively. Results showed that droplet motion exhibited less resistance along the longitudinal direction. Impact dynamic parameters, such as impact behaviors, maximum spreading factor, contact distance, and contact time were also investigated. Three different impact behaviors were categorized based on the normal component of Weber number irrespective of the inclination angle of the rice leaf. The asymmetric impact behavior induced by the tangential Weber number was also identified. Variation in the maximum spreading factor according to the normal Weber number was measured and compared with theoretical value obtained according to scaling law to show the wettability of the rice leaves. The contact distance of the impacting droplets depended on the inclination angle of the leaves. Along the longitudinal direction of rice leaves, contact distance was farther than that along the transverse direction. This result is consistent with the smaller values of CAH and α roll along the longitudinal direction.

  3. A comparison of force control algorithms for robots in contact with flexible environments

    NASA Technical Reports Server (NTRS)

    Wilfinger, Lee S.

    1992-01-01

    In order to perform useful tasks, the robot end-effector must come into contact with its environment. For such tasks, force feedback is frequently used to control the interaction forces. Control of these forces is complicated by the fact that the flexibility of the environment affects the stability of the force control algorithm. Because of the wide variety of different materials present in everyday environments, it is necessary to gain an understanding of how environmental flexibility affects the stability of force control algorithms. This report presents the theory and experimental results of two force control algorithms: Position Accommodation Control and Direct Force Servoing. The implementation of each of these algorithms on a two-arm robotic test bed located in the Center for Intelligent Robotic Systems for Space Exploration (CIRSSE) is discussed in detail. The behavior of each algorithm when contacting materials of different flexibility is experimentally determined. In addition, several robustness improvements to the Direct Force Servoing algorithm are suggested and experimentally verified. Finally, a qualitative comparison of the force control algorithms is provided, along with a description of a general tuning process for each control method.

  4. Measles on the Edge: Coastal Heterogeneities and Infection Dynamics

    PubMed Central

    Bharti, Nita; Xia, Yingcun; Bjornstad, Ottar N.; Grenfell, Bryan T.

    2008-01-01

    Mathematical models can help elucidate the spatio-temporal dynamics of epidemics as well as the impact of control measures. The gravity model for directly transmitted diseases is currently one of the most parsimonious models for spatial epidemic spread. This model uses distance-weighted, population size-dependent coupling to estimate host movement and disease incidence in metapopulations. The model captures overall measles dynamics in terms of underlying human movement in pre-vaccination England and Wales (previously established). In spatial models, edges often present a special challenge. Therefore, to test the model's robustness, we analyzed gravity model incidence predictions for coastal cities in England and Wales. Results show that, although predictions are accurate for inland towns, they significantly underestimate coastal persistence. We examine incidence, outbreak seasonality, and public transportation records, to show that the model's inaccuracies stem from an underestimation of total contacts per individual along the coast. We rescue this predicted ‘edge effect’ by increasing coastal contacts to approximate the number of per capita inland contacts. These results illustrate the impact of ‘edge effects’ on epidemic metapopulations in general and illustrate directions for the refinement of spatiotemporal epidemic models. PMID:18398467

  5. Effects of friction reduction of micro-patterned array of rough slider bearing

    NASA Astrophysics Data System (ADS)

    Kim, M.; Lee, D. W.; Jeong, J. H.; Chung, W. S.; Park, J. K.

    2017-08-01

    Complex micro-scale patterns have attracted interest because of the functionality that can be created using this type of patterning. This study evaluates the frictional reduction effects of various micro patterns on a slider bearing surface which is operating under mixed lubrication. Due to the rapid growth of contact area under mixed lubrication, it has become important to study the phenomenon of asperity contact in bearings with a heavy load. New analysis using the modified Reynolds equation with both the average flow model and the contact model of asperities is conducted for the rough slider bearing. A numerical analysis is performed to determine the effects of surface roughness on a lubricated bearing. Several dented patterns such as, dot pattern, dashed line patterns are used to evaluate frictional reduction effects. To verify the analytical results, friction test for the micro-patterned samples are performed. From comparing the frictional reduction effects of patterned arrays, the design of them can control the frictional loss of bearings. Our results showed that the design of pattern array on the bearing surface was important to the friction reduction of bearings. To reduce frictional loss, the longitudinal direction of them was better than the transverse direction.

  6. A Contact Pressure Analysis Comparing an All-Inside and Inside-Out Surgical Repair Technique for Bucket-Handle Medial Meniscus Tears.

    PubMed

    Marchetti, Daniel Cole; Phelps, Brian M; Dahl, Kimi D; Slette, Erik L; Mikula, Jacob D; Dornan, Grant J; Bucci, Gabriella; Turnbull, Travis Lee; Singleton, Steven B

    2017-10-01

    To directly compare effectiveness of the inside-out and all-inside medial meniscal repair techniques in restoring native contact area and contact pressure across the medial tibial plateau at multiple knee flexion angles. Twelve male, nonpaired (n = 12), fresh-frozen human cadaveric knees underwent a series of 5 consecutive states: (1) intact medial meniscus, (2) MCL tear and repair, (3) simulated bucket-handle longitudinal tear of the medial meniscus, (4) inside-out meniscal repair, and (5) all-inside meniscal repair. Knees were loaded with a 1,000-N axial compressive force at 5 knee flexion angles (0°, 30°, 45°, 60°, 90°), and contact area, mean contact pressure, and peak contact pressure were calculated using thin film pressure sensors. No significant differences were observed between the inside-out and all-inside repair techniques at any flexion angle for contact area, mean contact pressure, and peak contact pressure (all P > .791). Compared with the torn meniscus state, inside-out and all-inside repair techniques resulted in increased contact area at all flexion angles (all P < .005 and all P < .037, respectively), decreased mean contact pressure at all flexion angles (all P < .007 and all P < .001, respectively) except for 0° (P = .097 and P = .39, respectively), and decreased peak contact pressure at all flexion angles (all P < .001, all P < .001, respectively) except for 0° (P = .080 and P = .544, respectively). However, there were significant differences in contact area and peak contact pressure between the intact state and inside-out technique at angles ≥45° (all P < .014 and all P < .032, respectively). Additionally, there were significant differences between the intact state and all-inside technique in contact area at 60° and 90° and peak contact pressure at 90° (both P < .005 and P = .004, respectively). Median values of intact contact area, mean contact pressure, and peak contact pressure over the tested flexion angles ranged from 498 to 561 mm 2 , 786 to 997 N/mm 2 , and 1,990 to 2,215 N/mm 2 , respectively. Contact area, mean contact pressure, and peak contact pressure were not significantly different between the all-inside and inside-out repair techniques at any tested flexion angle. Both techniques adequately restored native meniscus biomechanics near an intact level. An all-inside repair technique provided similar, native-state-restoring contact mechanics compared with an inside-out repair technique for the treatment of displaced bucket-handle tears of the medial meniscus. Thus, both techniques may adequately decrease the likelihood of cartilage degeneration. Copyright © 2017 Arthroscopy Association of North America. Published by Elsevier Inc. All rights reserved.

  7. Predicting helix–helix interactions from residue contacts in membrane proteins

    PubMed Central

    Lo, Allan; Chiu, Yi-Yuan; Rødland, Einar Andreas; Lyu, Ping-Chiang; Sung, Ting-Yi; Hsu, Wen-Lian

    2009-01-01

    Motivation: Helix–helix interactions play a critical role in the structure assembly, stability and function of membrane proteins. On the molecular level, the interactions are mediated by one or more residue contacts. Although previous studies focused on helix-packing patterns and sequence motifs, few of them developed methods specifically for contact prediction. Results: We present a new hierarchical framework for contact prediction, with an application in membrane proteins. The hierarchical scheme consists of two levels: in the first level, contact residues are predicted from the sequence and their pairing relationships are further predicted in the second level. Statistical analyses on contact propensities are combined with other sequence and structural information for training the support vector machine classifiers. Evaluated on 52 protein chains using leave-one-out cross validation (LOOCV) and an independent test set of 14 protein chains, the two-level approach consistently improves the conventional direct approach in prediction accuracy, with 80% reduction of input for prediction. Furthermore, the predicted contacts are then used to infer interactions between pairs of helices. When at least three predicted contacts are required for an inferred interaction, the accuracy, sensitivity and specificity are 56%, 40% and 89%, respectively. Our results demonstrate that a hierarchical framework can be applied to eliminate false positives (FP) while reducing computational complexity in predicting contacts. Together with the estimated contact propensities, this method can be used to gain insights into helix-packing in membrane proteins. Availability: http://bio-cluster.iis.sinica.edu.tw/TMhit/ Contact: tsung@iis.sinica.edu.tw Supplementary information:Supplementary data are available at Bioinformatics online. PMID:19244388

  8. Direct-contact closed-loop heat exchanger

    DOEpatents

    Berry, Gregory F.; Minkov, Vladimir; Petrick, Michael

    1984-01-01

    A high temperature heat exchanger with a closed loop and a heat transfer liquid within the loop, the closed loop having a first horizontal channel with inlet and outlet means for providing direct contact of a first fluid at a first temperature with the heat transfer liquid, a second horizontal channel with inlet and outlet means for providing direct contact of a second fluid at a second temperature with the heat transfer liquid, and means for circulating the heat transfer liquid.

  9. Industrial Hardening: 1981 Technical Status-Report.

    DTIC Science & Technology

    1982-09-01

    preparedness for nuclear disaster ), establish additional industry contacts (through which to test and evaluate the new inputs and refinements), and...handling and control of toxic (and hazardous) materials in a nuclear disaster situation are desirable. In line with our strategy to seek overlapping...earthquake preparedness that apply to a nuclear disaster requires an analysis that is less direct than comparing ground shock. Earthquake-generated

  10. Characterization of plasma treated surfaces for food safety by terahertz spectroscopy

    NASA Astrophysics Data System (ADS)

    Sulovská, Kateřina; Lehocký, Marián.

    2014-10-01

    A physico-chemical approach to modify surfaces not only for use in medicine, but also for preservation of food is nowadays widely studied to lower the risks of increased number of bacterial pathogens that are in a direct contact with people. Food safety is very important part of preserving sustainability during crises, especially after the enterohaemorrhagic Escherichia coli outbreak in Europe in 2011. One of the possibility how we can protect food against various pathogens is the modification of packing materials that are directly in contact with preserved food. This contribution deals with the characterization of modified surfaces with antibacterial properties via Terahertz spectroscopy. For the purpose of this paper, three monomers were used for grafting onto air radiofrequency plasma activated low density polyethylene surface, which created a brush-like structure. Next, the antibacterial agents, Irgasan and Chlorhexidine, were anchored to these surfaces. These antibacterial agents were selected for supposed effect on two most frequently occurring bacterial strains - Escherichia coli and Staphylococcus aureus. Materials were further tested for the presence of antibacterial agent molecules, in our case by means of terahertz spectroscopy. Each material was tested on two spectroscopes - the SPECTRA and the OSCAT terahertz instruments.

  11. Eyelid Dermatitis: Contact Allergy to 3-(Dimethylamino)propylamine

    PubMed Central

    Knopp, Eleanor; Watsky, Kalman

    2014-01-01

    We present the case of a 42-year-old woman with intractable eyelid dermatitis. Patch testing revealed sensitization to 3-(dimethylamino)propylamine (DMAPA). DMAPA is an important etiology of allergic contact dermatitis of the eyelids and face but is easily missed even with expanded-series patch testing. We also review the most common causative allergens in eyelid dermatitis cited in the literature over the past decade. DMAPA is a reagent used in the formation of cocamidopropyl betaine (CAPB), a common additive to liquid soaps, shampoos, and other cleansing products because of its utility as a surfactant. Beginning in the 1980s, reports of allergy to CAPB surfaced in the literature. Ultimately, a majority of patch testing studies have shown that clinical allergy to CAPB-containing products actually reflects allergy to contaminant DMAPA in most cases. Amidoamine, another intermediate in the formation of CAPB, may also be implicated through a proposed mechanism of conversion to DMAPA in the skin. When patch-testing for eyelid and facial dermatitis, it is crucial to test with DMAPA directly, not just with CAPB; unlike commercial-grade CAPB, the CAPB in patch test kits is ultrapure and does not contain contaminant DMAPA. PMID:19134437

  12. Leptospirosis Outbreak following Severe Flooding: A Rapid Assessment and Mass Prophylaxis Campaign; Guyana, January–February 2005

    PubMed Central

    Dechet, Amy M.; Parsons, Michele; Rambaran, Madan; Mohamed-Rambaran, Pheona; Florendo-Cumbermack, Anita; Persaud, Shamdeo; Baboolal, Shirematee; Ari, Mary D.; Shadomy, Sean V.; Zaki, Sherif R.; Paddock, Christopher D.; Clark, Thomas A.; Harris, Lazenia; Lyon, Douglas; Mintz, Eric D.

    2012-01-01

    Background Leptospirosis is a zoonosis usually transmitted through contact with water or soil contaminated with urine from infected animals. Severe flooding can put individuals at greater risk for contracting leptospirosis in endemic areas. Rapid testing for the disease and large-scale interventions are necessary to identify and control infection. We describe a leptospirosis outbreak following severe flooding and a mass chemoprophylaxis campaign in Guyana. Methodology/Principal Findings From January–March 2005, we collected data on suspected leptospirosis hospitalizations and deaths. Laboratory testing included anti-leptospiral dot enzyme immunoassay (DST), immunohistochemistry (IHC) staining, and microscopic agglutination testing (MAT). DST testing was conducted for 105 (44%) of 236 patients; 52 (50%) tested positive. Four (57%) paired serum samples tested by MAT were confirmed leptospirosis. Of 34 total deaths attributed to leptospirosis, postmortem samples from 10 (83%) of 12 patients were positive by IHC. Of 201 patients interviewed, 89% reported direct contact with flood waters. A 3-week doxycycline chemoprophylaxis campaign reached over 280,000 people. Conclusions A confirmed leptospirosis outbreak in Guyana occurred after severe flooding, resulting in a massive chemoprophylaxis campaign to try to limit morbidity and mortality. PMID:22808049

  13. Evaluation and Management of Patch Test-Negative Patients With Generalized Dermatitis.

    PubMed

    Spiker, Alison; Mowad, Christen M

    Patients with generalized dermatitis are common in dermatology practices. Allergic contact dermatitis is often suspected, and patients frequently undergo patch testing. When the patch testing result is negative, further evaluation and management of these patients are challenging. The purpose of this study was to survey members of the American Contact Dermatitis Society regarding the evaluation and management of patch test-negative patients with generalized dermatitis. Generalized dermatitis was the most common term identified for patch test-negative patients with diffuse dermatitis. After having negative expanded patch testing results, most physicians proceeded with additional testing including skin biopsy, complete blood cell count with differential, and liver and renal function tests. The most commonly used systemic treatment is prednisone, followed by methotrexate. Narrow-band ultraviolet B (UVB) is the most commonly used light source. Antihistamines are frequently prescribed. Food allergy is not felt to be causative. This cohort of patients experiences significant impairment in quality of life, stress on personal relationships, and time off work. The management of patch test-negative patients with generalized dermatitis is challenging. This study provides insight into management of these complex patients. It also demonstrates practice gaps in the management of these patients, indicating a need for further studies to direct the evaluation and management of this patient population.

  14. Shear-Sensitive Liquid Crystal Coating Method Applied Through Transparent Test Surfaces

    NASA Technical Reports Server (NTRS)

    Reda, Daniel C.; Wilder, Michael C.

    1999-01-01

    Research conducted at NASA Ames Research Center has shown that the color-change response of a shear-sensitive liquid crystal coating (SSLCC) to aerodynamic shear depends on both the magnitude of the local shear vector and its direction relative to the observer's in-plane line of sight. In conventional applications, the surface of the SSLCC exposed to aerodynamic shear is illuminated with white light from the normal direction and observed from an oblique above-plane view angle of order 30 deg. In this top-light/top-view mode, shear vectors with components directed away from the observer cause the SSLCC to exhibit color-change responses. At any surface point, the maximum color change (measured from the no-shear red or orange color) always occurs when the local vector is aligned with, and directed away from, the observer. The magnitude of the color change at this vector-observer-aligned orientation scales directly with shear stress magnitude. Conversely, any surface point exposed to a shear vector with a component directed toward the observer exhibits a non-color-change response, always characterized by a rusty-red or brown color, independent of both shear magnitude and direction. These unique, highly directional color-change responses of SSLCCs to aerodynamic shear allow for the full-surface visualization and measurement of continuous shear stress vector distributions. The objective of the present research was to investigate application of the SSLCC method through a transparent test surface. In this new back-light/back-view mode, the exposed surface of the SSLCC would be subjected to aerodynamic shear stress while the contact surface between the SSLCC and the solid, transparent wall would be illuminated and viewed in the same geometrical arrangement as applied in conventional applications. It was unknown at the outset whether or not color-change responses would be observable from the contact surface of the SSLCC, and, if seen, how these color-change responses might relate to those observed in standard practice.

  15. Oncologists' non-verbal behavior and analog patients' recall of information.

    PubMed

    Hillen, Marij A; de Haes, Hanneke C J M; van Tienhoven, Geertjan; van Laarhoven, Hanneke W M; van Weert, Julia C M; Vermeulen, Daniëlle M; Smets, Ellen M A

    2016-06-01

    Background Information in oncological consultations is often excessive. Those patients who better recall information are more satisfied, less anxious and more adherent. Optimal recall may be enhanced by the oncologist's non-verbal communication. We tested the influence of three non-verbal behaviors, i.e. eye contact, body posture and smiling, on patients' recall of information and perceived friendliness of the oncologist. Moreover, the influence of patient characteristics on recall was examined, both directly or as a moderator of non-verbal communication. Material and methods Non-verbal communication of an oncologist was experimentally varied using video vignettes. In total 194 breast cancer patients/survivors and healthy women participated as 'analog patients', viewing a randomly selected video version while imagining themselves in the role of the patient. Directly after viewing, they evaluated the oncologist. From 24 to 48 hours later, participants' passive recall, i.e. recognition, and free recall of information provided by the oncologist were assessed. Results Participants' recognition was higher if the oncologist maintained more consistent eye contact (β = 0.17). More eye contact and smiling led to a perception of the oncologist as more friendly. Body posture and smiling did not significantly influence recall. Older age predicted significantly worse recognition (β = -0.28) and free recall (β = -0.34) of information. Conclusion Oncologists may be able to facilitate their patients' recall functioning through consistent eye contact. This seems particularly relevant for older patients, whose recall is significantly worse. These findings can be used in training, focused on how to maintain eye contact while managing computer tasks.

  16. Contact urticaria, allergic contact dermatitis, and photoallergic contact dermatitis from oxybenzone.

    PubMed

    Landers, Maeran; Law, Sandra; Storrs, Frances J

    2003-03-01

    There is little literature regarding conventional patch tests and photopatch tests to oxybenzone resulting in both immediate- and delayed-type hypersensitivity reactions. A patient was patch-tested and photopatch-tested to various sunscreen chemicals. Both immediate- and delayed-type hypersensitivity reactions were observed with oxybenzone. The positive patch tests were also photoaccentuated. Oxybenzone, a common sunscreen allergen, can result in both contact urticaria and delayed-type hypersensitivity on both conventional patch testing and photopatch testing. Allergic contact dermatitis to sunscreen chemicals has traditionally included contact urticaria, allergic contact dermatitis, and photoallergic contact dermatitis. Due to the recognition of p-aminobenzoic acid (PABA) and its esters as sensitizers, the presence of benzophenones in "PABA-free" sunscreens has become more prevalent, especially in sunscreens with a sun protection factor (SPF) greater than 8. In our patient, immediate- and delayed-type hypersensitivity reactions were seen to oxybenzone (2-hydroxy-4-methoxybenzophenone, 2-benzoyl-5-methoxyphenol, benzophenone-3, Eusolex 4360, Escalol 567, EUSORB 228, Spectra-Sorb UV-9, Uvinul M-40) upon conventional patch testing and photopatch testing.

  17. The influence of patellofemoral joint contact geometry on the modeling of three dimensional patellofemoral joint forces.

    PubMed

    Powers, Christopher M; Chen, Yu-Jen; Scher, Irving; Lee, Thay Q

    2006-01-01

    The purpose of this study was to determine the influence of patellofemoral joint contact geometry on the modeling of three-dimensional patellofemoral joint forces. To achieve this goal, patellofemoral joint reaction forces (PFJRFs) that were measured from an in-vitro cadaveric set-up were compared to PFJRFs estimated from a computer model that did not consider patellofemoral joint contact geometry. Ten cadaver knees were used in this study. Each was mounted on a custom jig that was fixed to an Instron frame. Quadriceps muscle loads were accomplished using a pulley system and weights. The force in the patellar ligament was obtained using a buckle transducer. To quantify the magnitude and direction of the PFJRF, a six-axis load cell was incorporated into the femoral fixation system so that a rigid body assumption could be made. PFJRF data were obtained at 0 degrees , 20 degrees , 40 degrees and 60 degrees of knee flexion. Following in vitro testing, SIMM modeling software was used to develop computational models based on the three-dimensional coordinates (Microscribe digitizer) of individual muscle and patellar ligament force vectors obtained from the cadaver knees. The overall magnitude of the PFJRF estimated from the computer generated models closely matched the direct measurements from the in vitro set-up (Pearson's correlation coefficient, R(2)=0.91, p<0.001). Although the computational model accurately estimated the posteriorly directed forces acting on the joint, some discrepancies were noted in the forces acting in the superior and lateral directions. These differences however, were relatively small when expressed as a total of the overall PFJRF magnitude.

  18. Direct-contact closed-loop heat exchanger

    DOEpatents

    Berry, G.F.; Minkov, V.; Petrick, M.

    1981-11-02

    A high temperature heat exchanger is disclosed which has a closed loop and a heat transfer liquid within the loop, the closed loop having a first horizontal channel with inlet and outlet means for providing direct contact of a first fluid at a first temperature with the heat transfer liquid, a second horizontal channel with inlet and outlet means for providing direct contact of a second fluid at a second temperature with the heat transfer liquid, and means for circulating the heat transfer liquid.

  19. Longitudinal assessment of anti-PGL-I serology in contacts of leprosy patients in Bangladesh

    PubMed Central

    van der Zwet, Konrad; van Hooij, Anouk; Wilson, Louis; Oskam, Linda; Faber, Roel; van den Eeden, Susan J. F.; Pahan, David; Alam, Khorshed; Richardus, Jan Hendrik; Geluk, Annemieke

    2017-01-01

    Background Despite elimination efforts, the number of Mycobacterium leprae (M. leprae) infected individuals who develop leprosy, is still substantial. Solid evidence exists that individuals living in close proximity to patients are at increased risk to develop leprosy. Early diagnosis of leprosy in endemic areas requires field-friendly tests that identify individuals at risk of developing the disease before clinical manifestation. Such assays will simultaneously contribute to reduction of current diagnostic delay as well as transmission. Antibody (Ab) levels directed against the M.leprae-specific phenolic glycolipid I (PGL-I) represents a surrogate marker for bacterial load. However, it is insufficiently defined whether anti-PGL-I antibodies can be utilized as prognostic biomarkers for disease in contacts. Particularly, in Bangladesh, where paucibacillary (PB) patients form the majority of leprosy cases, anti-PGL-I serology is an inadequate method for leprosy screening in contacts as a directive for prophylactic treatment. Methods Between 2002 and 2009, fingerstick blood from leprosy patients’ contacts without clinical signs of disease from a field-trial in Bangladesh was collected on filter paper at three time points covering six years of follow-up per person. Analysis of anti-PGL-I Ab levels for 25 contacts who developed leprosy during follow-up and 199 contacts who were not diagnosed with leprosy, was performed by ELISA after elution of bloodspots from filter paper. Results Anti-PGL-I Ab levels at intake did not significantly differ between contacts who developed leprosy during the study and those who remained free of disease. Moreover, anti-PGL-I serology was not prognostic in this population as no significant correlation was identified between anti-PGL-I Ab levels at intake and the onset of leprosy. Conclusion In this highly endemic population in Bangladesh, no association was observed between anti-PGL-I Ab levels and onset of disease, urging the need for an extended, more specific biomarker signature for early detection of leprosy in this area. Trial registration ClinicalTrials.gov ISRCTN61223447 PMID:29228004

  20. Longitudinal assessment of anti-PGL-I serology in contacts of leprosy patients in Bangladesh.

    PubMed

    Richardus, Renate A; van der Zwet, Konrad; van Hooij, Anouk; Wilson, Louis; Oskam, Linda; Faber, Roel; van den Eeden, Susan J F; Pahan, David; Alam, Khorshed; Richardus, Jan Hendrik; Geluk, Annemieke

    2017-12-01

    Despite elimination efforts, the number of Mycobacterium leprae (M. leprae) infected individuals who develop leprosy, is still substantial. Solid evidence exists that individuals living in close proximity to patients are at increased risk to develop leprosy. Early diagnosis of leprosy in endemic areas requires field-friendly tests that identify individuals at risk of developing the disease before clinical manifestation. Such assays will simultaneously contribute to reduction of current diagnostic delay as well as transmission. Antibody (Ab) levels directed against the M.leprae-specific phenolic glycolipid I (PGL-I) represents a surrogate marker for bacterial load. However, it is insufficiently defined whether anti-PGL-I antibodies can be utilized as prognostic biomarkers for disease in contacts. Particularly, in Bangladesh, where paucibacillary (PB) patients form the majority of leprosy cases, anti-PGL-I serology is an inadequate method for leprosy screening in contacts as a directive for prophylactic treatment. Between 2002 and 2009, fingerstick blood from leprosy patients' contacts without clinical signs of disease from a field-trial in Bangladesh was collected on filter paper at three time points covering six years of follow-up per person. Analysis of anti-PGL-I Ab levels for 25 contacts who developed leprosy during follow-up and 199 contacts who were not diagnosed with leprosy, was performed by ELISA after elution of bloodspots from filter paper. Anti-PGL-I Ab levels at intake did not significantly differ between contacts who developed leprosy during the study and those who remained free of disease. Moreover, anti-PGL-I serology was not prognostic in this population as no significant correlation was identified between anti-PGL-I Ab levels at intake and the onset of leprosy. In this highly endemic population in Bangladesh, no association was observed between anti-PGL-I Ab levels and onset of disease, urging the need for an extended, more specific biomarker signature for early detection of leprosy in this area. ClinicalTrials.gov ISRCTN61223447.

  1. Direct determination of three-phase contact line properties on nearly molecular scale

    DOE PAGES

    Winkler, P. M.; McGraw, R. L.; Bauer, P. S.; ...

    2016-05-17

    Wetting phenomena in multi-phase systems govern the shape of the contact line which separates the different phases. For liquids in contact with solid surfaces wetting is typically described in terms of contact angle. While in macroscopic systems the contact angle can be determined experimentally, on the molecular scale contact angles are hardly accessible. Here we report the first direct experimental determination of contact angles as well as contact line curvature on a scale of the order of 1nm. For water nucleating heterogeneously on Ag nanoparticles we find contact angles around 15 degrees compared to 90 degrees for the corresponding macroscopicallymore » measured equilibrium angle. The obtained microscopic contact angles can be attributed to negative line tension in the order of –10 –10 J/m that becomes increasingly dominant with increasing curvature of the contact line. Furthermore, these results enable a consistent theoretical description of heterogeneous nucleation and provide firm insight to the wetting of nanosized objects.« less

  2. Anisotropic forces from spatially constrained focal adhesions mediate contact guidance directed cell migration

    PubMed Central

    Ray, Arja; Lee, Oscar; Win, Zaw; Edwards, Rachel M.; Alford, Patrick W.; Kim, Deok-Ho; Provenzano, Paolo P.

    2017-01-01

    Directed migration by contact guidance is a poorly understood yet vital phenomenon, particularly for carcinoma cell invasion on aligned collagen fibres. We demonstrate that for single cells, aligned architectures providing contact guidance cues induce constrained focal adhesion maturation and associated F-actin alignment, consequently orchestrating anisotropic traction stresses that drive cell orientation and directional migration. Consistent with this understanding, relaxing spatial constraints to adhesion maturation either through reduction in substrate alignment density or reduction in adhesion size diminishes the contact guidance response. While such interactions allow single mesenchymal-like cells to spontaneously ‘sense' and follow topographic alignment, intercellular interactions within epithelial clusters temper anisotropic cell–substratum forces, resulting in substantially lower directional response. Overall, these results point to the control of contact guidance by a balance of cell–substratum and cell–cell interactions, modulated by cell phenotype-specific cytoskeletal arrangements. Thus, our findings elucidate how phenotypically diverse cells perceive ECM alignment at the molecular level. PMID:28401884

  3. Direct Laser Writing of Nanophotonic Structures on Contact Lenses.

    PubMed

    AlQattan, Bader; Yetisen, Ali K; Butt, Haider

    2018-04-24

    Contact lenses are ubiquitous biomedical devices used for vision correction and cosmetic purposes. Their application as quantitative analytical devices is highly promising for point-of-care diagnostics. However, it is a challenge to integrate nanoscale features into commercial contact lenses for application in low-cost biosensors. A neodymium-doped yttrium aluminum garnet (Nd:YAG) laser (1064 nm, 3 ns pulse, 240 mJ) in holographic interference patterning mode was utilized to produce optical nanostructures over the surface of a hydrogel contact lens. One-dimensional (925 nm) and two-dimensional (925 nm × 925 nm) nanostructures were produced on contact lenses and analyzed by spectroscopy and angle-resolve measurements. The holographic properties of these nanostructures were tested in ambient moisture, fully hydrated, and artificial tear conditions. The measurements showed a rapid tuning of optical diffraction from these nanostructures from 41 to 48°. The nanostructures were patterned near the edges of the contact lens to avoid any interference and obstruction to the human vision. The formation of 2D nanostructures on lenses increased the diffraction efficiency by more than 10%. The versatility of the holographic laser ablation method was demonstrated by producing four different 2D nanopattern geometries on contact lenses. Hydrophobicity of the contact lens was characterized by contact angle measurements, which increased from 59.0° at pristine condition to 62.5° at post-nanofabrication. The holographic nanostructures on the contact lens were used to sense the concentration of Na + ions. Artificial tear solution was used to simulate the conditions in dry eye syndrome, and nanostructures on the contact lenses were used to detect the electrolyte concentration changes (±47 mmol L -1 ). Nanopatterns on a contact lens may be used to sense other ocular diseases in early stages at point-of-care settings.

  4. Image based weighted center of proximity versus directly measured knee contact location during simulated gait

    PubMed Central

    Wang, Hongsheng; Chen, Tony; Koff, Matthew F.; Hutchinson, Ian D.; Gilbert, Susannah; Choi, Dan; Warren, Russell F.; Rodeo, Scott A.; Maher, Suzanne A.

    2014-01-01

    To understand the mechanical consequences of knee injury requires a detailed analysis of the effect of that injury on joint contact mechanics during activities of daily living. Three-dimensional (3D) knee joint geometric models have been combined with knee joint kinematics to dynamically estimate the location of joint contact during physiological activities – using a weighted center of proximity (WCoP) method. However, the relationship between the estimated WCoP and the actual location of contact has not been defined. The objective of this study was to assess the relationship between knee joint contact location as estimated using the image-based WCoP method, and a directly measured weighted center of contact (WCoC) method during simulated walking. To achieve this goal, we created knee specific models of six human cadaveric knees from magnetic resonance imaging. All knees were then subjected to physiological loads on a knee simulator intended to mimic gait. Knee joint motion was captured using a motion capture system. Knee joint contact stresses were synchronously recorded using a thin electronic sensor throughout gait, and used to compute WCoC for the medial and lateral plateaus of each knee. WCoP was calculated by combining knee kinematics with the MRI-based knee specific model. Both metrics were compared throughout gait using linear regression. The anteroposterior (AP) location of WCoP was significantly correlated with that of WCoC on both tibial plateaus in all specimens (P < 0.01, 95% confidence interval of Person’s coefficient r > 0), but the correlation was not significant in the mediolateral (ML) direction for 4/6 knees (P > 0.05). Our study demonstrates that while the location of joint contact obtained from 3D knee joint contact model, using the WCoP method, is significantly correlated with the location of actual contact stresses in the AP direction, that relationship is less certain in the ML direction. PMID:24837219

  5. Diagnosis, prevention, and treatment of scabies.

    PubMed

    Shimose, Luis; Munoz-Price, L Silvia

    2013-10-01

    Scabies remains a public health problem, especially in developing countries, with a worldwide incidence of approximately 300 million cases each year. Prolonged skin-to-skin contact is necessary to allow the transmission of the causative mite, Sarcoptes scabiei. Classic scabies presents with burrows, erythematous papules, and generalized pruritus. Clinical variants include nodular scabies and crusted scabies, also called Norwegian scabies. The diagnosis is based mainly on history and physical examination, but definitive diagnosis depends on direct visualization of the mites under microscopy. Alternative diagnostic methods include the burrow ink test, video-dermatoscopy, newly serologic tests like PCR/ELISA, and specific IgE directed toward major mite components. Treatment of scabies consists of either topical permethrin or oral ivermectin, although the optimal regimen is still unclear.

  6. Scabies.

    PubMed

    Hicks, Maria I; Elston, Dirk M

    2009-01-01

    Scabies is an ectoparasite caused by the mite Sarcoptes scabiei var hominis, an obligate human parasite. There are about 300 million cases of scabies in the world each year. Common predisposing factors are overcrowding, immigration, poor hygiene, poor nutritional status, homelessness, dementia, and sexual contact. Direct skin-to-skin contact between 15 and 20 minutes is needed to transfer the mites from one person to another. The diagnosis suspected with a clinical history of itch, worse at night, affecting other family members, clinical distribution, and appearance. Definite diagnosis relies on microscopic identification of the mites, eggs, or fecal pellets with 10% potassium hydroxide, ink enhancement, tetracycline fluorescence tests, or mineral oil; other methods include: epiluminescence light microscopy and S. scabiei DNA. The most commonly used treatment modalities are permethrin and ivermectin. Persistence of symptoms for 2-6 weeks after successful treatment is common. Most recurrences are because of reinfection from untreated contacts.

  7. Sheep Feed and Scrapie, France

    PubMed Central

    Philippe, Sandrine; Ducrot, Christian; Roy, Pascal; Remontet, Laurent; Jarrige, Nathalie

    2005-01-01

    Scrapie is a small ruminant, transmissible spongiform encephalopathy (TSE). Although in the past scrapie has not been considered a zoonosis, the emergence of bovine spongiform encephalopathy, transmissible to humans and experimentally to sheep, indicates that risk exists for small ruminant TSEs in humans. To identify the risk factors for introducing scrapie into sheep flocks, a case-control study was conducted in France from 1999 to 2000. Ninety-four case and 350 control flocks were matched by location and main breed. Three main hypotheses were tested: direct contact between flocks, indirect environmental contact, and foodborne risk. Statistical analysis was performed by using adjusted generalized linear models with the complementary log-log link function, considering flock size as an offset. A notable effect of using proprietary concentrates and milk replacers was observed. The risk was heterogeneous among feed factories. Contacts between flocks were not shown to be a risk factor. PMID:16102318

  8. Thermal elastohydrodynamic lubrication of spur gears

    NASA Technical Reports Server (NTRS)

    Wang, K. L.; Cheng, H. S.

    1980-01-01

    An analysis and computer program called TELSGE were developed to predict the variations of dynamic load, surface temperature, and lubricant film thickness along the contacting path during the engagement of a pair of involute spur gears. The analysis of dynamic load includes the effect of gear inertia, the effect of load sharing of adjacent teeth, and the effect of variable tooth stiffness which are obtained by a finite-element method. Results obtained from TELSGE for the dynamic load distributions along the contacting path for various speeds of a pair of test gears show patterns similar to that observed experimentally. Effects of damping ratio, contact ratio, tip relief, and tooth error on the dynamic load were examined. In addition, two dimensionless charts are included for predicting the maximum equilibrium surface temperature, which can be used to estimate directly the lubricant film thickness based on well established EHD analysis.

  9. Investigation into the mechanisms of closed three-body abrasive wear

    NASA Astrophysics Data System (ADS)

    Dwyer-Joyce, R. S.; Sayles, R. S.; Ioannides, E.

    1994-06-01

    Contacting components frequently fail by abrasion caused by solid contaminants in the lubricant. This process can be classified as a closed three-body abrasive wear process. The mechanisms by which trapped particles cause material removal are not fully understood. This paper describes tests using model elastohydrodynamic contacts to study these mechanisms. An optical elastohydrodynamic lubrication rig has been used to study the deformation and fracture of ductile and brittle lubricant-borne debris. A ball-on-disk machine was used to study the behavior of the particles in partially sliding contacts. Small diamond particles were used as abrasives since these were thought not to break down in the contact; wear could then be directly related to particles of a known size. The particles were found to embed in the softer surface and to scratch the harder. The mass of material worn from the ball surface was approximately proportional to the particle sliding distance and abrasive concentration. Small particles tumbled through the contact, while larger particles ploughed. Mass loss was found to increase with abrasive particle size. Individual abrasion scratches have been measured and related to the abrading particle. A simple model of the abrasive process has been developed and compared with experimental data. The discrepancies are thought to be the result of the uncertainty about the entrainment of particles into the contact.

  10. Luminous fabric devices for wearable low-level light therapy

    PubMed Central

    Shen, Jing; Chui, Chunghin; Tao, Xiaoming

    2013-01-01

    In this paper, a flexible luminous fabric device was developed and investigated for wearable three-dimensionally fitted low-level light therapy. The fabric device exhibited excellent optical and thermal properties. Its optical power density and operating temperature were stable during usage for 10 hours. In vitro experiments demonstrated a significant increase in collagen production in human fibroblast irradiated by the fabric device, compared with the fibroblast without light irradiation. A series of tests were conducted for the safety of the fabric for human skin contact according to ISO standard ISO 10993-1:2003. The results showed that there was no potential hazard when the luminous fabrics were in direct contact with human skin. PMID:24409391

  11. Development of multichannel soft tactile sensors having fingerprint structure.

    PubMed

    Tsutsui, H; Murashima, Y; Honma, N; Kobayashi, K

    2014-01-01

    It is possible to accurately recognize the shape of an object or to grip it by setting soft tactile sensors on a robot's hands. We studied a multichannel soft tactile sensor as an artificial hand and evaluated the pressure's response performance from several directions and the slipping and sliding responses. The tactile sensor consisted of multiple pneumatic sensors and a soft cap with a fingerprint structure that was made of silicone gum and was separated from multiple spaces. Evaluation tests showed that the multiple soft tactile sensors estimate both an object's contact force and its contact location. Our tactile sensor also measured the object's roughness by the slide on surface texture.

  12. Mentalizing eye contact with a face on a video: Gaze direction does not influence autonomic arousal.

    PubMed

    Lyyra, Pessi; Myllyneva, Aki; Hietanen, Jari K

    2018-04-26

    Recent research has revealed enhanced autonomic and subjective responses to eye contact only when perceiving another live person. However, these enhanced responses to eye contact are abolished if the viewer believes that the other person is not able to look back at the viewer. We purported to investigate whether this "genuine" eye contact effect can be reproduced with pre-recorded videos of stimulus persons. Autonomic responses, gaze behavior, and subjective self-assessments were measured while participants viewed pre-recorded video persons with direct or averted gaze, imagined that the video person was real, and mentalized that the person could see them or not. Pre-recorded videos did not evoke similar physiological or subjective eye contact effect as previously observed with live persons, not even when the participants were mentalizing being seen by the person. Gaze tracking results showed, however, increased attention allocation to faces with direct gaze compared to averted gaze directions. The results suggest that elicitation of the physiological arousal in response to genuine eye contact seems to require spontaneous experience of seeing and of being seen by another individual. © 2018 Scandinavian Psychological Associations and John Wiley & Sons Ltd.

  13. Compatibility between Co-Metallized PbTe Thermoelectric Legs and an Ag-Cu-In Brazing Alloy.

    PubMed

    Ben-Ayoun, Dana; Sadia, Yatir; Gelbstein, Yaniv

    2018-01-10

    In thermoelectric (TE) generators, maximizing the efficiency of conversion of direct heat to electricity requires the reduction of any thermal and electrical contact resistances between the TE legs and the metallic contacts. This requirement is especially challenging in the development of intermediate to high-temperature TE generators. PbTe-based TE materials are known to be highly efficient up to temperatures of around 500 °C; however, only a few practical TE generators based on these materials are currently commercially available. One reason for that is the insufficient bonding techniques between the TE legs and the hot-side metallic contacts. The current research is focused on the interaction between cobalt-metallized n -type 9.104 × 10 -3 mol % PbI₂-doped PbTe TE legs and the Ag 0.32 Cu 0.43 In 0.25 brazing alloy, which is free of volatile species. Clear and fine interfaces without any noticeable formation of adverse brittle intermetallic compounds were observed following prolonged thermal treatment testing. Moreover, a reasonable electrical contact resistance of ~2.25 mΩmm² was observed upon brazing at 600 °C, highlighting the potential of such contacts while developing practical PbTe-based TE generators.

  14. Optimized programming algorithm for cylindrical and directional deep brain stimulation electrodes.

    PubMed

    Anderson, Daria Nesterovich; Osting, Braxton; Vorwerk, Johannes; Dorval, Alan D; Butson, Christopher R

    2018-04-01

    Deep brain stimulation (DBS) is a growing treatment option for movement and psychiatric disorders. As DBS technology moves toward directional leads with increased numbers of smaller electrode contacts, trial-and-error methods of manual DBS programming are becoming too time-consuming for clinical feasibility. We propose an algorithm to automate DBS programming in near real-time for a wide range of DBS lead designs. Magnetic resonance imaging and diffusion tensor imaging are used to build finite element models that include anisotropic conductivity. The algorithm maximizes activation of target tissue and utilizes the Hessian matrix of the electric potential to approximate activation of neurons in all directions. We demonstrate our algorithm's ability in an example programming case that targets the subthalamic nucleus (STN) for the treatment of Parkinson's disease for three lead designs: the Medtronic 3389 (four cylindrical contacts), the direct STNAcute (two cylindrical contacts, six directional contacts), and the Medtronic-Sapiens lead (40 directional contacts). The optimization algorithm returns patient-specific contact configurations in near real-time-less than 10 s for even the most complex leads. When the lead was placed centrally in the target STN, the directional leads were able to activate over 50% of the region, whereas the Medtronic 3389 could activate only 40%. When the lead was placed 2 mm lateral to the target, the directional leads performed as well as they did in the central position, but the Medtronic 3389 activated only 2.9% of the STN. This DBS programming algorithm can be applied to cylindrical electrodes as well as novel directional leads that are too complex with modern technology to be manually programmed. This algorithm may reduce clinical programming time and encourage the use of directional leads, since they activate a larger volume of the target area than cylindrical electrodes in central and off-target lead placements.

  15. Toxicity and biocompatibility profile of 3D bone scaffold developed by Universitas Indonesia: A preliminary study

    NASA Astrophysics Data System (ADS)

    Rahyussalim A., J.; Kurniawati, T.; Aprilya, D.; Anggraini, R.; Ramahdita, Ghiska; Whulanza, Yudan

    2017-02-01

    Scaffold as a biomaterial must fulfill some requirements to be safely implanted to the human body. Toxicity and biocompatibility test are needed to evaluate scaffold material in mediating cell proliferation and differentiation, secreting extracelullar matrix and carrying biomolecular signals for cell communication. An in vitro study with mesenchymal stem cells consisted of direct contact test and indirect contact test using MTT (3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide) tetrazolium reduction assay was conducted on 4 scaffolds made of poly-L-lactic acid (PLA), polyvinyl alcohol (PVA), and hydroxyapatite-poly (vinyl alcohol) composite. There were cells-substrate adhesion impairment, morphological changes, cell death and reduction in cell proliferation seen at 2nd and 6th day in most tested scaffold. Cell count result at day-6 showed proliferation inhibition of more than 50% cell death (inhibition value >50) in all tested scaffold. In MTT assay, two scaffolds were proven non-toxic. In conclusion, various scaffold materials showed different toxicity effect. The toxicity and biocompatibility profile in this study is a preliminary data for further research aiming to use those local-made scaffolds to fill human bone defect in various needs.

  16. Non-Dissipative Structural Evolutions in Granular Materials

    NASA Astrophysics Data System (ADS)

    Pouragha, Mehdi; Wan, Richard

    2017-06-01

    The structure of the contact network in granular assemblies can evolve due to either dissipative mechanisms such as sliding at contact points, or non-dissipative mechanisms through the phenomenon of contact gain and loss. Being associated with negligible deformations, non-dissipative mechanisms is actually active even in the small strain range of 10-3, especially in the case of densely packed assemblies. Hence, from a constitutive modelling point of view, it is crucial to be able to estimate such non-dissipative evolutions since both elastic and plastic properties of granular assemblies highly depend on contact network characteristics. The current study proposes an analytical scheme that allows us to estimate the non-dissipative contact gain/loss regime in terms of directional changes in the average contact force. The probability distribution of contact forces is used to compute the number of lost contact for each direction. Similarly, the number of newly formed contacts is estimated by considering the probability distribution of the gap between neighbouring particles. Based on the directional contact gain/loss computed, the changes in coordination number and fabric anisotropy can be found which, together with statistical treatments of Love-Weber stress expression, form a complete system of equations describing the evolution of other controlling microvariables. Finally, the results of the calculations have been compared with DEM simulations which verify the accuracy of the proposed scheme.

  17. Special tinted contact lens on colour-defects.

    PubMed

    Mutilab, H A; Sharanjeet-Kaur; Keu, L K; Choo, P F

    2012-01-01

    The objective of this study was to determine the visual function of colour-deficient subjects when wearing special red tint contact lenses. A total of 17 subjects with congenital colour vision deficiency (14 deutans and 3 protans), voluntarily participated in this study. The average age for the subjects was 23.00 ± 4.06 years old. Visual functions tested were visual acuity (LogMAR), contrast sensitivity (FACT Chart) and stereopsis (TNO and Howard Dolman tests). Two types of special red tint lenses were used in this study; Type I (light red) and Type II (dark red). The protans and deutans showed no significant changes in visual acuity and contrast sensitivity when wearing either type of contact lens. Stereopsis testing using the Horward-Dolman test gave no significant changes but significant differences were seen using the TNO test. Stereopsis using the TNO test was significantly poorer with the red tinted contact lenses compared to without for both protons and deutans. Testing binocularly with Ishihara plates showed that 88% (n=15) of patients passed the test with Type I and Type II contact lenses. When D15 test was done, 3 patients (17.6%) were 'normal' when using the Type I contact lenses and 2 patients (11.8%) were 'normal' when using the Type II contact lenses. However, with FM100Hue test, most patients showed deutan responses. Total error scores (TES) were found to be higher with Type I and Type II contact lenses compared to without. The Type I and II special tinted contact lens used in this study did not cause a reduction of visual acuity and contrast sensitivity for the colour defects. Stereopsis was also not reduced with the Type I and Type II contact lenses for the colour defects except when tested with the TNO test. Colour vision defects became difficult to detect using the Ishihara plates but FM100Hue test did not show any improvement with the Type I and Type II contact lenses.

  18. A comparison of Quincke and Whitacre needles with respect to risk of intravascular uptake in S1 transforaminal epidural steroid injections: a randomized trial of 1376 cases.

    PubMed

    Shin, Jaehyuck; Kim, Yong Chul; Lee, Sang Chul; Kim, Jae Hun

    2013-11-01

    Transforaminal epidural steroid injection (TFESI) is a useful treatment modality for pain management. Most complications of TFESI are minor and transient. However, there is a risk of serious complications such as nerve injury, spinal cord infarct, or paraplegia. Some of the risks are related to direct injury to the vessel or intravascular injection of the particulate steroid. We prospectively tested the hypothesis that the intravascular injection rate of the Whitacre needle is lower than that of the Quincke needle during TFESI. This study was a randomized trial of 1376 TFESIs at the S1 level. We collected data of age, gender, height, weight, laterality (right/left), history of lumbosacral spine operation, history of appropriate interval discontinuation of anticoagulation medicines, and underlying disease. During the S1 TFESI, intrasacral bone contact, a blood aspiration test, and real-time fluoroscopy of the intravascular injection using contrast media were investigated. There were no significant differences in the intravascular injection rate with respect to age, gender, height, weight, hypertension, diabetes mellitus, laterality, history of lumbosacral spine operation, or history of appropriate interval discontinuation of anticoagulation medicines. Intravascular injection was significantly associated with a blood aspiration test (P < 0.001), needle tip type (P = 0.002), intrasacral bone contact (P < 0.001), and physicians (some P < 0.05). The use of Quincke needles and intrasacral bone contact increased the rate of intravascular injection. To reduce the risk of intravascular injection, the use of Whitacre needles without intrasacral bone contact may be a safer and more effective approach.

  19. Occupational allergic contact dermatitis from epoxy resin in a golf club repairman.

    PubMed

    Isaksson, Marléne; Möller, Halvor; Pontén, Ann

    2008-01-01

    A golfer presented with facial and hand eczema. He had exacerbations of his hand eczema prior to golf tournaments. Being an authorized golf club repairman, he had been working with a two-part glue containing an epoxy resin (ER) based on diglycidyl ether of bisphenol A (DGEBA) and the hardener diethylenetriamine (DETA) for approximately 4 years before he developed any skin problems. He was patch-tested with the standard, which contains an ER based on DGEBA (DGEBA-R), epoxy (containing DETA), and rubber glove series and had positive reactions to DGEBA-R only. Other work materials (a latex glove, a golf glove made of leather, and part of the handle of his own golf club "as is" and in a methyl tert-butyl ether extract) were tested, with negative results. Allergic contact dermatitis from ER affects the skin by direct contact; the dermatitis is usually localized to the hands and forearms. If the face and eyelids are involved, the dermatitis may be due to exposure to airborne hardeners or reactive diluents, exposure to airborne dust from residual monomers, or ectopic allergic reactions. Our repairman had sandpapered an old glued surface, which may have led to possible airborne dust formation, thus explaining the facial eczema. Therefore, a worker with contact allergy to ER may continue working provided the skin is protected from contamination.

  20. Cultural differences in self-recognition: the early development of autonomous and related selves?

    PubMed

    Ross, Josephine; Yilmaz, Mandy; Dale, Rachel; Cassidy, Rose; Yildirim, Iraz; Suzanne Zeedyk, M

    2017-05-01

    Fifteen- to 18-month-old infants from three nationalities were observed interacting with their mothers and during two self-recognition tasks. Scottish interactions were characterized by distal contact, Zambian interactions by proximal contact, and Turkish interactions by a mixture of contact strategies. These culturally distinct experiences may scaffold different perspectives on self. In support, Scottish infants performed best in a task requiring recognition of the self in an individualistic context (mirror self-recognition), whereas Zambian infants performed best in a task requiring recognition of the self in a less individualistic context (body-as-obstacle task). Turkish infants performed similarly to Zambian infants on the body-as-obstacle task, but outperformed Zambians on the mirror self-recognition task. Verbal contact (a distal strategy) was positively related to mirror self-recognition and negatively related to passing the body-as-obstacle task. Directive action and speech (proximal strategies) were negatively related to mirror self-recognition. Self-awareness performance was best predicted by cultural context; autonomous settings predicted success in mirror self-recognition, and related settings predicted success in the body-as-obstacle task. These novel data substantiate the idea that cultural factors may play a role in the early expression of self-awareness. More broadly, the results highlight the importance of moving beyond the mark test, and designing culturally sensitive tests of self-awareness. © 2016 John Wiley & Sons Ltd.

  1. Comparing maximum intercuspal contacts of virtual dental patients and mounted dental casts.

    PubMed

    Delong, Ralph; Ko, Ching-Chang; Anderson, Gary C; Hodges, James S; Douglas, W H

    2002-12-01

    Quantitative measures of occlusal contacts are of paramount importance in the study of chewing dysfunction. A tool is needed to identify and quantify occlusal parameters without occlusal interference caused by the technique of analysis. This laboratory simulation study compared occlusal contacts constructed from 3-dimensional images of dental casts and interocclusal records with contacts found by use of conventional methods. Dental casts of 10 completely dentate adults were mounted in a semi-adjustable Denar articulator. Maximum intercuspal contacts were marked on the casts using red film. Intercuspal records made with an experimental vinyl polysiloxane impression material recorded maximum intercuspation. Three-dimensional virtual models of the casts and interocclusal records were made using custom software and an optical scanner. Contacts were calculated between virtual casts aligned manually (CM), aligned with interocclusal records scanned seated on the mandibular casts (C1) or scanned independently (C2), and directly from virtual interocclusal records (IR). Sensitivity and specificity calculations used the marked contacts as the standard. Contact parameters were compared between method pairs. Statistical comparisons used analysis of variance and the Tukey-Kramer post hoc test (P=<.05). Sensitivities (range 0.76-0.89) did not differ significantly among the 4 methods (P=.14); however, specificities (range 0.89-0.98) were significantly lower for IR (P=.0001). Contact parameters of methods CM, C1, and C2 differed significantly from those of method IR (P<.02). The ranking based on method pair comparisons was C2/C1 > CM/C1 = CM/C2 > C2/IR > CM/IR > C1/IR, where ">" means "closer than." Within the limits of this study, occlusal contacts calculated from aligned virtual casts accurately reproduce articulator contacts.

  2. 77 FR 47361 - Proposed Information Collection; Comment Request; 2013 Alternative Contact Strategy Test

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-08-08

    ... research will be conducted through a series of projects and tests throughout the decade. Contact involving... 2020 Research and Testing Project tests and design options for the 2020 Census. II. Method of... Alternative Contact Strategy Test is the first test to support this research. The Census Bureau will test...

  3. In vivo anatomical analysis of arterial contact with trigeminal nerve: detection with three-dimensional spoiled grass imaging.

    PubMed

    Ueda, F; Suzuki, M; Fujinaga, Y; Kadoya, M; Takashima, T

    1999-09-01

    The purpose of this study was to review the normal in vivo neurovascular relationship between the trigeminal nerve and surrounding arteries without the use of volunteers. 290 nerves in 145 cases were reviewed during a 1-year period. Axial source images and multiplanar reconstructed (MPR) images were used to determine the neurovascular contact and direction of contact. Multiplanar volume reformation (MPVR) was used to identify the contact vessels and to demonstrate the relationship between the nerve and arteries. Vascular contact was found in 29% of the 290 nerves (83 nerves). The arteries involved were the superior cerebellar artery (SCA) or the anterior inferior cerebellar artery (AICA). Vascular contact with two arteries was found in 3%. Of the 286 asymptomatic nerves, the nerve was located between the two vessels in 3% and compression was seen in 1%. Three points of vascular contact by the two arteries were identified in one asymptomatic nerve. The direction of contact between the SCA and the nerve was superior (38%), superomedial (32%) or medial (15%) in most cases. The direction of contact between the AICA and the nerve was inferior, inferolateral or lateral in all cases. Vascular contact at the root entry zone (REZ) was noted in 90%. Four nerves were affected by trigeminal neuralgia, one of which touched an artery and two were compressed. It was concluded that arterial contact can be assessed without difficulty but evaluation of vascular compression is not easy.

  4. Embedded Strain Gauges for Condition Monitoring of Silicone Gaskets

    PubMed Central

    Schotzko, Timo; Lang, Walter

    2014-01-01

    A miniaturized strain gauge with a thickness of 5 µm is molded into a silicone O-ring. This is a first step toward embedding sensors in gaskets for structural health monitoring. The signal of the integrated sensor exhibits a linear correlation with the contact pressure of the O-ring. This affords the opportunity to monitor the gasket condition during installation. Thus, damages caused by faulty assembly can be detected instantly, and early failures, with their associated consequences, can be prevented. Through the embedded strain gauge, the contact pressure applied to the gasket can be directly measured. Excessive pressure and incorrect positioning of the gasket can cause structural damage to the material of the gasket, which can lead to an early outage. A platinum strain gauge is fabricated on a thin polyimide layer and is contacted through gold connections. The measured resistance pressure response exhibits hysteresis for the first few strain cycles, followed by a linear behavior. The short-term impact of the embedded sensor on the stability of the gasket is investigated. Pull-tests with O-rings and test specimens have indicated that the integration of the miniaturized sensors has no negative impact on the stability in the short term. PMID:25014099

  5. [Neurocysticercosis and occupational medicine].

    PubMed

    Salazar Schettino, B; de Haro, I; Robert Guerrero, L; Gutiérrez Quiroz, M; Salazar Schettino, P M

    1990-01-01

    Twenty individuals classified as disabled due to diagnosed cerebral cysticercosis were studied to correlate the presence of neurocysticercosis with the history of having worked in contact with organic solvents as possible triggering agents of the pathology. The study was performed by direct or indirect interrogatory, review of the case histories, serologic examinations, and psychological evaluation of the intellectual performance level and psychopathological index. Of the 20 subjects, 50% had been exposed to organic solvents in their work; all had been in contact with the infecting parasite, either through frequent consumption of pork meat, or through contact with fecal mass. The titers of the haemagglutination test varied from 1:2 to 1:256, being the diagnosis value of > or = 1:16. There was also a variation as a function of the antigen used for the sera tests performed in the sampled subjects, such as complete or incomplete somatic antigen, vesicular fluid, and excretions and secretions. Other variations found, such as symptoms and the results of the psychological evaluation are depicted in tables. It is concluded that in these cases, neurocysticercosis is an invalidating disease, and the presence of organic solvents is emphasized as an important factor of the disease or as a triggering factor.

  6. Use of mobile phones and text messaging to decrease the turnaround time for early infant HIV diagnosis and notification in rural Zambia: an observational study.

    PubMed

    Sutcliffe, Catherine G; Thuma, Philip E; van Dijk, Janneke H; Sinywimaanzi, Kathy; Mweetwa, Sydney; Hamahuwa, Mutinta; Moss, William J

    2017-03-08

    Early infant diagnosis of HIV infection is challenging in rural sub-Saharan Africa as blood samples are sent to central laboratories for HIV DNA testing, leading to delays in diagnosis and treatment initiation. Simple technologies to rapidly deliver results to clinics and notify mothers of test results would decrease many of these delays. The feasibility of using mobile phones to contact mothers was evaluated. In addition, the first two years of implementation of a national short message service (SMS) reporting system to deliver test results from the laboratory to the clinic were evaluated. The study was conducted in Macha, Zambia from 2013 to 2015 among mothers of HIV-exposed infants. Mothers were interviewed about mobile phone use and willingness to be contacted directly or through their rural health center. Mothers were contacted according to their preferred method of communication when test results were available. Mothers of positive infants were asked to return to the clinic as soon as possible. Dates of sample collection, delivery of test results to the clinic and notification of mothers were documented in addition to test results. Four hundred nineteen mothers and infants were enrolled. Only 30% of mothers had ever used a mobile phone. 96% of mobile phone owners were reached by study staff and 98% of mothers without mobile phones were contacted through their rural health center. Turnaround times for mothers of positive infants were approximately 2 weeks shorter than for mothers of negative infants. Delivery of test results by the national SMS system improved from 2013 to 2014, with increases in the availability of texted results (38 vs. 91%) and arrival of the texted result prior to the hardcopy report (27 vs. 83%). Texted results arriving at the clinic before the hardcopy were received a median of 19 days earlier. Four discrepancies between texted and hardcopy results were identified out of 340 tests. Mobile phone and text messaging technology has the potential to improve early infant diagnosis but challenges to widespread implementation need to be addressed, including low mobile phone ownership, use and coverage in rural areas.

  7. A randomized trial of the effect of prayer on depression and anxiety.

    PubMed

    Boelens, Peter A; Reeves, Roy R; Replogle, William H; Koenig, Harold G

    2009-01-01

    To investigate the effect of direct contact person-to-person prayer on depression, anxiety, positive emotions, and salivary cortisol levels. Cross-over clinical trial with depression or anxiety conducted in an office setting. Following randomization to the prayer intervention or control groups, subjects (95% women) completed Hamilton Rating Scales for Depression and Anxiety, Life Orientation Test, Daily Spiritual Experiences Scale, and underwent measurement of cortisol levels. Individuals in the direct person-to-person prayer contact intervention group received six weekly 1-hour prayer sessions while those in the control group received none. Rating scales and cortisol levels were repeated for both groups after completion of the prayer sessions, and a month later. ANOVAs were used to compare pre- and post-prayer measures for each group. At the completion of the trial, participants receiving the prayer intervention showed significant improvement of depression and anxiety, as well as increases of daily spiritual experiences and optimism compared to controls (p < 0.01 in all cases). Subjects in the prayer group maintained these significant improvements (p < 0.01 in all cases) for a duration of at least 1 month after the final prayer session. Participants in the control group did not show significant changes during the study. Cortisol levels did not differ significantly between intervention and control groups, or between pre- and post-prayer conditions. Direct contact person-to-person prayer may be useful as an adjunct to standard medical care for patients with depression and anxiety. Further research in this area is indicated.

  8. Contamination profile of Listeria spp. in three types of ready-to-eat chicken meat products.

    PubMed

    Lekroengsin, Sumalin; Keeratipibul, Suwimon; Trakoonlerswilai, Kasame

    2007-01-01

    This study investigated contamination sources of Listeria spp. in frozen, ready-to-eat, roasted, steamed, and fried chicken meat products from a plant in Thailand, as well as the correlation between Listeria contamination in the production environment and the finished product. The cooking processes used in this factory (with a product core temperature of 80 degrees C for 1 min) were confirmed as adequate for eliminating Listeria spp. However, Listeria spp. were detected at the packing stage of roasted and steamed chicken products. An environmental swab test was conducted by means of the zone concept, whereby surfaces in the production area were divided into three zones. Zone 1 was made up of the equipment surfaces that came into direct contact with the products. Zone 2 consisted of equipment surfaces that were not in direct contact with the products, including surfaces that were difficult to be cleaned. Zone 3 included surfaces that did not come in direct contact with the products and were located far from the products. The results showed that the prevalence of Listeria spp. in roasted and steamed products was affected by the prevalence of Listeria contamination in all zones, especially zone 1, which demonstrated the highest correlation. In addition, the prevalence of Listeria contamination in zones 2 and 3 affected the prevalence of Listeria in zone 1. A correlation between Listeria on roasted chicken products and the surfaces of zone 1 at the start of production was also established.

  9. Knee Contact Force Asymmetries in Patients Who Failed Return-to-Sport Readiness Criteria 6 Months After Anterior Cruciate Ligament Reconstruction

    PubMed Central

    Gardinier, Emily S.; Di Stasi, Stephanie; Manal, Kurt; Buchanan, Thomas S.; Snyder-Mackler, Lynn

    2015-01-01

    Background After anterior cruciate ligament (ACL) injury, contact forces are decreased in the injured knee when compared with the uninjured knee. The persistence of contact force asymmetries after ACL reconstruction may increase the risk of reinjury and may play an important role in the development of knee osteoarthritis in these patients. Functional performance may also be useful in identifying patients who demonstrate potentially harmful joint contact force asymmetries after ACL reconstruction. Hypothesis Knee joint contact force asymmetries would be present during gait after ACL reconstruction, and performance on a specific set of validated return-to-sport (RTS) readiness criteria would discriminate between those who demonstrated contact force asymmetries and those who did not. Study Design Descriptive laboratory study. Methods A total of 29 patients with ACL ruptures participated in gait analysis and RTS readiness testing 6 months after reconstruction. Muscle and joint contact forces were estimated using an electromyography (EMG)–driven musculoskeletal model of the knee. The magnitude of typical limb asymmetry in uninjured controls was used to define limits of meaningful limb asymmetry in patients after ACL reconstruction. The RTS testing included isometric quadriceps strength testing, 4 unilateral hop tests, and 2 self-report questionnaires. Paired t tests were used to assess limb symmetry for peak medial and tibiofemoral contact forces in all patients, and a mixed-design analysis of variance was used to analyze the effect of passing or failing RTS testing on contact force asymmetry. Results Among all patients, neither statistically significant nor meaningful contact force asymmetries were identified. However, patients who failed RTS testing exhibited meaningful contact force asymmetries, with tibiofemoral contact force being significantly lower for the involved knee. Conversely, patients who passed RTS testing exhibited neither significant nor meaningful contact force asymmetries. Conclusion Joint contact force asymmetries during gait are present in some patients 6 months after ACL reconstruction. Patients who demonstrated poor functional performance on RTS readiness testing exhibited significant and meaningful contact force asymmetries. Clinical Relevance When assessing all patients together, variability in the functional status obscured significant and meaningful differences in contact force asymmetry in patients 6 months after ACL reconstruction. These specific RTS readiness criteria appear to differentiate between those who demonstrate joint contact force symmetry after ACL reconstruction and those who do not. PMID:25318940

  10. Fabrication of 3D surface structures using grayscale lithography

    NASA Astrophysics Data System (ADS)

    Stilson, Christopher; Pal, Rajan; Coutu, Ronald A.

    2014-03-01

    The ability to design and develop 3D microstructures is important for microelectromechanical systems (MEMS) fabrication. Previous techniques used to create 3D devices included tedious steps in direct writing and aligning patterns onto a substrate followed by multiple photolithography steps using expensive, customized equipment. Additionally, these techniques restricted batch processing and placed limits on achievable shapes. Gray-scale lithography enables the fabrication of a variety of shapes using a single photolithography step followed by reactive ion etching (RIE). Micromachining 3D silicon structures for MEMS can be accomplished using gray-scale lithography along with dry anisotropic etching. In this study, we investigated: using MATLAB for mask designs; feasibility of using 1 μm Heidelberg mask maker to direct write patterns onto photoresist; using RIE processing to etch patterns into a silicon substrate; and the ability to tailor etch selectivity for precise fabrication. To determine etch rates and to obtain desired etch selectivity, parameters such as gas mixture, gas flow, and electrode power were studied. This process successfully demonstrates the ability to use gray-scale lithography and RIE for use in the study of micro-contacts. These results were used to produce a known engineered non-planer surface for testing micro-contacts. Surface structures are between 5 μm and 20 μm wide with varying depths and slopes based on mask design and etch rate selectivity. The engineered surfaces will provide more insight into contact geometries and failure modes of fixed-fixed micro-contacts.

  11. Simulated impact damage in a thick graphite/epoxy laminate using spherical indenters

    NASA Technical Reports Server (NTRS)

    Poe, C. C., Jr.

    1988-01-01

    A study was made to determine the extent of fiber damage caused by low-velocity impact of spherical impactors to a very thick graphite/epoxy laminate. The laminate was cut from a filament wound case being developed for the Space Shuttle solid rocket motors. The case was wound using a wet process with AS4W graphite fiber and HBRF-55A epoxy. Impacts were simulated under quasi-static conditions by pressing hemispherically shaped indenters against the laminate at different locations. The contact force and indenter diameter were varied from location to location. The forces were chosen for each indenter diameter to produce contact pressures below and above that required to initiate damage. After the forces were applied, the laminate was cut into smaller pieces so that each piece contained a test site. The pieces were then deplied and the individual plies examined to determine the extent of fiber damage. Broken fibers were found in the outer layers directly beneath the contact site. The locus of broken fibers in each layer resembled a crack normal to the direction of the fibers. The maximum length and depth of the cracks increased with increasing contact pressure and indenter diameter. The internal stresses in the laminate were calculated using Hertz's law and Love's solution for pressure applied on part of the boundary of a semi-infinite body. The maximum length and depth of the cracks were predicted using a maximum shear stress criterion. Predictions and measurements were in good agreement.

  12. Mechanical Determinants of Faster Change of Direction Speed Performance in Male Athletes.

    PubMed

    DosʼSantos, Thomas; Thomas, Christopher; Jones, Paul A; Comfort, Paul

    2017-03-01

    Dos'Santos, T, Thomas, C, Jones, PA, and Comfort, P. Mechanical determinants of faster change of direction speed performance in male athletes. J Strength Cond Res 31(3): 696-705, 2017-Mechanical variables during change of directions, for example, braking and propulsive forces, impulses, and ground contact times (GCT) have been identified as determinants of faster change of direction speed (CODS) performance. The purpose of this study was to investigate the mechanical determinants of 180° CODS performance with mechanical characteristic comparisons between faster and slower performers; while exploring the role of the penultimate foot contact (PEN) during the change of direction. Forty multidirectional male athletes performed 6 modified 505 (mod505) trials (3 left and right), and ground reaction forces were collected across the PEN and final foot contact (FINAL) during the change of direction. Pearson's correlation coefficients and coefficients of determination were used to explore the relationship between mechanical variables and mod505 completion time. Independent T-tests and Cohen's d effect sizes (ES) were conducted between faster (n = 10) and slower (n = 10) mod505 performers to explore differences in mechanical variables. Faster CODS performance was associated (p ≤ 0.05) with shorter GCTs (r = 0.701-0.757), greater horizontal propulsive forces (HPF) (r = -0.572 to -0.611), greater horizontal braking forces (HBF) in the PEN (r = -0.337), lower HBF ratios (r = -0.429), and lower FINAL vertical impact forces (VIF) (r = 0.449-0.559). Faster athletes demonstrated significantly (p ≤ 0.05, ES = 1.08-2.54) shorter FINAL GCTs, produced lower VIF, lower HBF ratios, and greater HPF in comparison to slower athletes. These findings suggest that different mechanical properties are required to produce faster CODS performance, with differences in mechanical properties observed between fast and slower performers. Furthermore, applying a greater proportion of braking force during the PEN relative to the FINAL may be advantageous for turning performance.

  13. EAACI position paper for practical patch testing in allergic contact dermatitis in children.

    PubMed

    de Waard-van der Spek, Flora B; Darsow, Ulf; Mortz, Charlotte G; Orton, David; Worm, Margitta; Muraro, Antonella; Schmid-Grendelmeier, Peter; Grimalt, Ramon; Spiewak, Radoslaw; Rudzeviciene, Odilija; Flohr, Carsten; Halken, Susanne; Fiocchi, Alessandro; Borrego, Luis Miguel; Oranje, Arnold P

    2015-11-01

    Allergic contact dermatitis (ACD) in children appears to be on the increase, and contact sensitization may already begin in infancy. The diagnosis of contact dermatitis requires a careful evaluation of a patient's clinical history, physical examination, and skin testing. Patch testing is the gold standard diagnostic test. Based on consensus, the EAACI Task Force on Allergic Contact Dermatitis in Children produced this document to provide details on clinical aspects, the standardization of patch test methodology, and suggestions for future research in the field. We provide a baseline list of test allergens to be tested in children with suspected ACD. Additional tests should be performed only on specific indications. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  14. Piezoviscosity In Lubrication Of Nonconformal Contacts

    NASA Technical Reports Server (NTRS)

    Jeng, Yeau-Ren; Hamrock, Bernard J.; Brewe, David E.

    1988-01-01

    Developments in theory of lubrication. Analysis of piezoviscous-rigid regime of lubrication of two ellipsoidal contacts. Begins with Reynolds equation for point contact. Equation nondimensionalized using Roelands empirical formula and Dowson and Higginson formula. Equation solved numerically. Solutions obtained for full spectrum of conditions to find effects of dimensionless load, speed, parameters of lubricated and lubricating materials, and angle between direction of rolling and direction of entrainment of lubricant.

  15. PDGF-A suppresses contact inhibition during directional collective cell migration.

    PubMed

    Nagel, Martina; Winklbauer, Rudolf

    2018-06-08

    The leading edge mesendoderm (LEM) of the Xenopus gastrula moves as an aggregate by collective migration. However, LEM cells on fibronectin in vitro show contact inhibition of locomotion by quickly retracting lamellipodia upon mutual contact. We found that a fibronectin-integrin-syndecan module acts between p21-activated kinase-1 upstream and ephrinB1 downstream to promote the contact-induced collapse of lamellipodia. To function in this module, fibronectin has to be present as puncta on the surface of LEM cells. To overcome contact inhibition in LEM cell aggregates, PDGF-A deposited in the endogenous substratum of LEM migration blocks the fibronectin-integrin-syndecan module at the integrin level. This stabilizes lamellipodia preferentially in the direction of normal LEM movement and supports cell orientation and the directional migration of the coherent LEM cell mass. © 2018. Published by The Company of Biologists Ltd.

  16. Evaluation of Contact Separation Force Testing as a Screening Methodology for Electrical Socket Contacts

    NASA Technical Reports Server (NTRS)

    Green, Chris; Greenwell, Chris; Brusse, jay; Krus, Dennis; Leidecker, Henning

    2009-01-01

    During system level testing intermittent and permanent open circuit failures of mated, crimp removable, electrical contact pairs were experienced. The root cause of the failures was determined to be low (but not zero) contact forces applied by the socket contact tines against the engaging pin. The low contact force reduces the effectiveness of the wiping action of the socket tines against the pin. The observed failure mode may be produced when insufficient wiping during mate, demate and small relative movement in use allows for the accumulation of debris or insulating films that electrically separate the contact pair. The investigation identified at least three manufacturing process control problems associated with the socket contacts that enabled shipment of contacts susceptible to developing low contact forces: (1) Improper heat treatment of the socket tines resulting in plastic rather than elastic behavior; (2) Overly thinned socket tines at their base resulting in reduced pin retention forces; (3) insufficient screening tests to identify parts susceptible to the aforementioned failure mechanisms. The results from an extensive screening program of socket contacts utilizing the industry standard contact separation force test procedures are described herein. The investigation shows this method to be capable of identifying initially weak sockets. However, sockets whose contact retention forces may degrade during use may not be screened out by pin retention testing alone. Further investigations are required to correlate low contact retention forces with increased electrical contact resistance in the presence of insulating films that may accumulate in the use environment.

  17. Coaxial test fixture

    DOEpatents

    Praeg, W.F.

    1984-03-30

    This invention pertains to arrangements for performing electrical tests on contact material samples, and in particular for testing contact material test samples in an evacuated environment under high current loads. Frequently, it is desirable in developing high-current separable contact material, to have at least a preliminary analysis of selected candidate conductor materials. Testing of material samples will hopefully identify materials unsuitable for high current electrical contact without requiring incorporation of the materials into a completed and oftentimes complex structure.

  18. In vitro effects of two silicate-based materials, Biodentine and BioRoot RCS, on dental pulp stem cells in models of reactionary and reparative dentinogenesis

    PubMed Central

    Loison-Robert, Ludwig Stanislas; Berbar, Tsouria; Isaac, Juliane; Berdal, Ariane; Simon, Stéphane

    2018-01-01

    Background Calcium silicate-based cements are biomaterials with calcium oxide and carbonate filler additives. Their properties are close to those of dentin, making them useful in restorative dentistry and endodontics. The aim of this study was to evaluate the in vitro biological effects of two such calcium silicate cements, Biodentine (BD) and Bioroot (BR), on dental stem cells in both direct and indirect contact models. The two models used aimed to mimic reparative dentin formation (direct contact) and reactionary dentin formation (indirect contact). An original aspect of this study is the use of an interposed thin agarose gel layer to assess the effects of diffusible components from the materials. Results The two biomaterials were compared and did not modify dental pulp stem cell (DPSC) proliferation. BD and BR showed no significant cytotoxicity, although some cell death occurred in direct contact. No apoptosis or inflammation induction was detected. A striking increase of mineralization induction was observed in the presence of BD and BR, and this effect was greater in direct contact. Surprisingly, biomineralization occurred even in the absence of mineralization medium. This differentiation was accompanied by expression of odontoblast-associated genes. Exposure by indirect contact did not stimulate the induction to such a level. Conclusion These two biomaterials both seem to be bioactive and biocompatible, preserving DPSC proliferation, migration and adhesion. The observed strong mineralization induction through direct contact highlights the potential of these biomaterials for clinical application in dentin-pulp complex regeneration. PMID:29370163

  19. A comparative evaluation of antimicrobial efficacy and flow properties for Epiphany, Guttaflow and AH-Plus sealer.

    PubMed

    Nawal, R R; Parande, M; Sehgal, R; Naik, A; Rao, N R

    2011-04-01

    To test the antimicrobial efficacy and flow properties of Guttaflow, Epiphany sealer and AH-Plus sealer. With the use of Enterococcus faecalis ATCC 29212 as a test organism, both the agar diffusion test (ADT) and direct contact test (DCT) were performed. For DCT, sealers were mixed and placed over the bottom of sterile screw-capped test tubes. A 50 μL bacterial suspension was placed on the tested material samples. Bacteria were allowed to directly come in contact with the sealers for 1 h at 37 °C in one group and for 24 h in the other group. The suspensions were then diluted and inoculated over blood agar plates, and bacterial colony counts were determined with the use of a digital colony counter. The data in both 1- and 24-h groups were individually analysed using repeated measures ANOVA. Kruskal Wallis tests were further used to obtain comparison between 1- and 24-h results for all three sealers. In the flow assay, the sealers were placed between two glass slides, and a weight of 500 g was placed on the top of the glass. The diameters of the formed discs were recorded. For both the ADT and DCT tests, Epiphany and AH-Plus sealer reduced the bacterial counts significantly (P = 0.000). Epiphany produced a greater reduction in bacterial counts when compared to AH-Plus in both the tests (P = 0.000). Guttaflow paste failed to show any antibacterial activity in both ADT & DCT. According to the flow test, all root canal sealers flowed; Epiphany sealer had the maximum flow under the given conditions, followed by AH-Plus sealer and Guttaflow paste. Antimicrobial activity of the sealers was greatest for Epiphany followed by AH-Plus sealer and Guttaflow. Epiphany sealer had the maximum flow followed by AH-Plus sealer and Guttaflow. © 2010 International Endodontic Journal.

  20. Development of Technologies on Innovative-Simplified Nuclear Power Plant using High-Efficiency Steam Injectors

    NASA Astrophysics Data System (ADS)

    Ohmori, Shuichi; Narabayashi, Tadashi; Mori, Michitsugu; Iwaki, Chikako; Asanuma, Yutaka; Goto, Shoji

    A Steam Injector (SI) is a simple, compact and passive pump and also acts as a high-performance direct-contact heater. This provides SI with capability to serve also as a direct-contact feed-water heater that heats up feed-water by using extracted steam from turbine. Our technology development aims to significantly simplify equipment and reduce physical quantities by applying "High-Efficiency SI", which are applicable to a wide range of operation regimes beyond the performance and applicable range of existing SIs and enables unprecedented multistage and parallel operation, to the low-pressure feed-water heaters and Emergency Core Cooling System of nuclear power plants, as well as achieve high inherent safety to prevent severe accidents by keeping the core covered with water (a Severe Accident-Free Concept). This paper describes the results of the endurance and performance tests of low-pressure SIs for feed-water heaters with Jet-deaerator and core injection system.

  1. Simulated impact damage in a thick graphite/epoxy laminate using spherical indenters

    NASA Technical Reports Server (NTRS)

    Poe, C. C., Jr.

    1988-01-01

    The extent of fiber damage due to low-velocity impacts was determined for very thick graphite/epoxy laminates. The impacts were simulated by pressing spherical indenters against the laminates. After the forces were applied, the laminate was cut into smaller pieces so that each piece contained a test site. Then the pieces were deplied and the individual plies were examined to determine the extent of fiber damage. Broken fibers were found in the outer layers directly beneath the contact site. The locus of broken fibers resembled cracks. The cracks were more or less oriented in the direction of the fibers in the contiguous layers. The maximum length and depth of the cracks increased with increasing contact pressure and indenter diameter. The length and depth of the cracks were also predicted using maximum compression and shear stress criteria. The internal stresses were calculated using Hertz's law and Love's solution for pressure applied on part of the boundary of a semi-infinite body. The predictions and measurements were in good agreement.

  2. Design and construction of a point-contact spectroscopy rig with lateral scanning capability.

    PubMed

    Tortello, M; Park, W K; Ascencio, C O; Saraf, P; Greene, L H

    2016-06-01

    The design and realization of a cryogenic rig for point-contact spectroscopy measurements in the needle-anvil configuration is presented. Thanks to the use of two piezoelectric nano-positioners, the tip can move along the vertical (z) and horizontal (x) direction and thus the rig is suitable to probe different regions of a sample in situ. Moreover, it can also form double point-contacts on different facets of a single crystal for achieving, e.g., an interferometer configuration for phase-sensitive measurements. For the later purpose, the sample holder can also host a Helmholtz coil for applying a small transverse magnetic field to the junction. A semi-rigid coaxial cable can be easily added for studying the behavior of Josephson junctions under microwave irradiation. The rig can be detached from the probe and thus used with different cryostats. The performance of this new probe has been tested in a Quantum Design PPMS system by conducting point-contact Andreev reflection measurements on Nb thin films over large areas as a function of temperature and magnetic field.

  3. Design and construction of a point-contact spectroscopy rig with lateral scanning capability

    NASA Astrophysics Data System (ADS)

    Tortello, M.; Park, W. K.; Ascencio, C. O.; Saraf, P.; Greene, L. H.

    2016-06-01

    The design and realization of a cryogenic rig for point-contact spectroscopy measurements in the needle-anvil configuration is presented. Thanks to the use of two piezoelectric nano-positioners, the tip can move along the vertical (z) and horizontal (x) direction and thus the rig is suitable to probe different regions of a sample in situ. Moreover, it can also form double point-contacts on different facets of a single crystal for achieving, e.g., an interferometer configuration for phase-sensitive measurements. For the later purpose, the sample holder can also host a Helmholtz coil for applying a small transverse magnetic field to the junction. A semi-rigid coaxial cable can be easily added for studying the behavior of Josephson junctions under microwave irradiation. The rig can be detached from the probe and thus used with different cryostats. The performance of this new probe has been tested in a Quantum Design PPMS system by conducting point-contact Andreev reflection measurements on Nb thin films over large areas as a function of temperature and magnetic field.

  4. Design and construction of a point-contact spectroscopy rig with lateral scanning capability

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Tortello, M.; Park, W. K., E-mail: wkpark@illinois.edu; Ascencio, C. O.

    2016-06-15

    The design and realization of a cryogenic rig for point-contact spectroscopy measurements in the needle-anvil configuration is presented. Thanks to the use of two piezoelectric nano-positioners, the tip can move along the vertical (z) and horizontal (x) direction and thus the rig is suitable to probe different regions of a sample in situ. Moreover, it can also form double point-contacts on different facets of a single crystal for achieving, e.g., an interferometer configuration for phase-sensitive measurements. For the later purpose, the sample holder can also host a Helmholtz coil for applying a small transverse magnetic field to the junction. Amore » semi-rigid coaxial cable can be easily added for studying the behavior of Josephson junctions under microwave irradiation. The rig can be detached from the probe and thus used with different cryostats. The performance of this new probe has been tested in a Quantum Design PPMS system by conducting point-contact Andreev reflection measurements on Nb thin films over large areas as a function of temperature and magnetic field.« less

  5. Effect of geometric nonlinearity on acoustic modulation

    NASA Astrophysics Data System (ADS)

    Warnemuende, Kraig; Wu, Hwai-Chung

    2005-05-01

    Non-linear nondestructive testing is different from linear acoustic in that it correlates the presence and characteristics of a defect with acoustical signals whose frequencies differ from the frequencies of the emitted probe signal. The difference in frequencies between the probe signal and the resulting frequencies is due to a nonlinear transformation of the probe signal as it passes through a defect. Under acoustic interrogation due to longitudinal waves, as the compression phase passes the defect the two sides of the interface are in direct contact and the contact area increases. Similarly, the tensile phase passes through the defect, the two sides separate and the contact area decreases, thereby modulating the signal amplitude. The contact area depends on the roughness of the surface and on the magnitude of the cohesive forces that arise from the small crack openings. Such cohesive forces may be attributed to aggregate interlock (in plain concrete), fiber bridging (in fiber reinforced concrete) or both. In this paper, the frequency shifts of the probe elastic wave will be analytically related to the roughness and varying cohesive forces of the crack-like defect.

  6. Classification of hand eczema.

    PubMed

    Agner, T; Aalto-Korte, K; Andersen, K E; Foti, C; Gimenéz-Arnau, A; Goncalo, M; Goossens, A; Le Coz, C; Diepgen, T L

    2015-12-01

    Classification of hand eczema (HE) is mandatory in epidemiological and clinical studies, and also important in clinical work. The aim was to test a recently proposed classification system of HE in clinical practice in a prospective multicentre study. Patients were recruited from nine different tertiary referral centres. All patients underwent examination by specialists in dermatology and were checked using relevant allergy testing. Patients were classified into one of the six diagnostic subgroups of HE: allergic contact dermatitis, irritant contact dermatitis, atopic HE, protein contact dermatitis/contact urticaria, hyperkeratotic endogenous eczema and vesicular endogenous eczema, respectively. An additional diagnosis was given if symptoms indicated that factors additional to the main diagnosis were of importance for the disease. Four hundred and twenty-seven patients were included, 379 (89%) of the patients could be classified directly into one of the six diagnostic subgroups, with irritant and allergic contact dermatitis comprising 249 patients (58%). For 32 (7%) more than one of the six diagnostic subgroups had been formulated as a main diagnosis, and 16 (4%) could not be classified. 38% had one additional diagnosis and 26% had two or more additional diagnoses. Eczema on feet was found in 30% of the patients, statistically significantly more frequently associated with hyperkeratotic and vesicular endogenous eczema. We find that the classification system investigated in the present study was useful, being able to give an appropriate main diagnosis for 89% of HE patients, and for another 7% when using two main diagnoses. The fact that more than half of the patients had one or more additional diagnoses illustrates that HE is a multifactorial disease. © 2015 European Academy of Dermatology and Venereology.

  7. Modal analysis of a loaded tire with non-contact measurements and piezoelectric excitation

    NASA Astrophysics Data System (ADS)

    Ferhat, Ipar; Tarazaga, Pablo A.

    2017-04-01

    The complex nature of tires requires very precise test data to model the structure accurately. The highly damped characteristics, geometric features and operational conditions of tires cause various testing difficulties that affect the reliability of the modal testing. One of the biggest challenges of tire testing is exciting the whole tire at once. Conventionally, impact hammers, shakers, and cleats are used as an excitation input. The shortcomings of these excitation methods are the directional and force inconsistency of hammer impacts, coupled dynamics of shakers and speed limitations of cleat excitation. Other challenges of modal testing of tires are the effect of added mass due to sensor placements and difficulty of vibration measurement of a rotating tire with accelerometers. In order to remedy these problems, we conduct experimental modal analysis (EMA) using a non-contact measurement technique and piezoelectric excitation. For non-contact measurement, a 3-D scanning laser doppler vibrometer (SLDV) is used. For the piezoelectric excitation, Micro Fiber Composite (MFC) patches are used due to their flexible nature and power capacity. This excitation method can also be crucial to the excitation of rotating tires since the cleat excitation is not adequate for low-speed measurements. Furthermore, the piezoelectric actuation could be used as sensors as well as noise controllers in operating conditions. For this work, we run experiments for a loaded tire in non-rotating condition. Experiments are carried out for the frequency bandwidth up to 500Hz to capture the structural behavior under high-frequency excitations and its potential coupled behavior to airborne noise.

  8. Negligible effect of competition on coral colony growth.

    PubMed

    Álvarez-Noriega, Mariana; Baird, Andrew H; Dornelas, Maria; Madin, Joshua S; Connolly, Sean R

    2018-06-01

    Competition is an important determinant of assemblage structure and population regulation, often resulting in decreased growth, fecundity or survival. In corals, most studies testing for an effect of competition on demographic traits, such as growth, have been experimental and often impose very high levels of competition upon colonies. To more realistically assess the role of competition on coral traits, multispecies studies in the wild are required. Here, we use 5 yr of data that includes 11 coral species on the reef crest at Lizard Island on the Great Barrier Reef to quantify the effect of competition on growth. Additionally, we test whether species differ in their susceptibility to direct-contact (overgrowth and digestion) and overtopping competition, and whether species from some morphological groups are more likely to compete with one another than with species from other morphological groups. We also investigate the relationships between competitive ability and three key traits: growth rate, mechanical stability and fecundity. In contrast to most previous work using field manipulations of competition, we found a negligible effect of competition on growth. Acropora species consistently won overtopping encounters but lost in direct-contact encounters, and these results were consistent among the four Acropora morphological groups. In contrast, the massive Goniastrea spp. were poor at overtopping but generally won direct-contact encounters. Only tabular colonies were disproportionally more likely to compete against one another than with other morphologies. This propensity increases intraspecific relative to interspecific competition, a phenomenon that can promote coexistence when it is present among dominant competitors. Good competitors grew more quickly and had higher fecundity but were less mechanically stable, implying a tradeoff between performance during disturbance vs. performance in the absence of disturbance. We conclude that competition among adults is less likely to influence community dynamics than previously thought. If competition does have an effect, it is more likely to occur at life-stages other than adults. © 2018 by the Ecological Society of America.

  9. Contact reactions to fragrances.

    PubMed

    Katsarou, A; Armenaka, M; Kalogeromitros, D; Koufou, V; Georgala, S

    1999-05-01

    The most common reaction to fragrances is contact dermatitis, a delayed hypersensitivity reaction; however, other reactions include immediate contact reactions (contact urticaria) and photo-allergic reactions. Fragrance mix (FM) and balsam of Peru (BP) are used to screen for fragrance allergy. To study the different types of allergic skin reactions to fragrance compounds. Delayed hypersensitivity reactions to FM and BP were studied in 4,975 patients with suspected contact dermatitis by routine patch testing interpreted at 48 and 96 hours. In 664 of the patients, patch tests were read at 30 minutes to evaluate for immediate (wheal-and-flare) contact reactions and again at 48 and 96 hours. Photopatch tests to FM were performed in 111 patients with suspected photo-allergic dermatitis. Delayed contact reactions to FM occurred in 6.6% of females and 5.4% of males and to BP in 3.9% of females and 4.1% of males. Analysis of data over time (12 study years) showed an increased trend for reactions to fragrances, particularly in males. Sensitivity to other contact allergens (polysensitivity) was found in 62% of patients and polysensitivity presented more often with generalized contact dermatitis. The most sensitizing components of the fragrance mix that were tested in 38 patients were cinnamic alcohol, oak moss, and cinnamic aldehyde. There were 112 immediate patch test reactions to FM and 113 to BP in 664 patients. Immediate contact reactions were followed by delayed contact reactions in 13.4% of patients for FM and 8.8% for BP, representing a significant increase in the frequency of delayed contact reactions. Patients with immediate contact reactions to fragrances did not have a higher incidence of atopy (25.9%). No cases of positive photopatch test reactions to FM were seen. Fragrances commonly cause both delayed and immediate patch test reactions and patients with immediate contact reactions have an increase in delayed contact reactions to the same allergen.

  10. Three distinct mechanisms predominate in non-contact anterior cruciate ligament injuries in male professional football players: a systematic video analysis of 39 cases

    PubMed Central

    Waldén, Markus; Krosshaug, Tron; Bjørneboe, John; Andersen, Thor Einar; Faul, Oliver

    2015-01-01

    Background Current knowledge on anterior cruciate ligament (ACL) injury mechanisms in male football players is limited. Aim To describe ACL injury mechanisms in male professional football players using systematic video analysis. Methods We assessed videos from 39 complete ACL tears recorded via prospective professional football injury surveillance between 2001 and 2011. Five analysts independently reviewed all videos to estimate the time of initial foot contact with the ground and the time of ACL tear. We then analysed all videos according to a structured format describing the injury circumstances and lower limb joint biomechanics. Results Twenty-five injuries were non-contact, eight indirect contact and six direct contact injuries. We identified three main categories of non-contact and indirect contact injury situations: (1) pressing (n=11), (2) re-gaining balance after kicking (n=5) and (3) landing after heading (n=5). The fourth main injury situation was direct contact with the injured leg or knee (n=6). Knee valgus was frequently seen in the main categories of non-contact and indirect contact playing situations (n=11), but a dynamic valgus collapse was infrequent (n=3). This was in contrast to the tackling-induced direct contact situations where a knee valgus collapse occurred in all cases (n=3). Conclusions Eighty-five per cent of the ACL injuries in male professional football players resulted from non-contact or indirect contact mechanisms. The most common playing situation leading to injury was pressing followed by kicking and heading. Knee valgus was frequently seen regardless of the playing situation, but a dynamic valgus collapse was rare. PMID:25907183

  11. A randomized controlled trial comparing three invitation strategies in a breast cancer screening program.

    PubMed

    Segura, J M; Castells, X; Casamitjana, M; Macià, F; Porta, M; Katz, S J

    2001-10-01

    The objective of this study was to compare the response received by a population-based breast cancer screening program, according to three different invitation strategies: letters sent by mail from the program (program group), letters sent by mail from the Primary Health Care Team (PHT group), and direct contact through a trained professional (direct contact group). We used a cluster-randomized controlled trial with assignment to invitation group using home address. Nine hundred eighty-six women of Barcelona (Spain), ages 50 to 64 years, were invited to participate in the program. The main outcome used was the response rate after the first invitation. Five hundred sixty-four women accepted the invitation (57.2%). The highest response rate was achieved in the direct contact group (63.5%), followed by the PHT group (55.6%), the program group being the one that attained the lowest response rate (52.1%). The direct contact group had a higher probability of participating than the PHT group (RR = 1.14, P = 0.037) or the program group (RR = 1.22, P = 0.003). The response rate in the direct contact group was 72.1% when the letter was received by the subject herself. The increase in response occurred particularly among women of lower educational level. Inviting women to participate in a breast cancer screening program through direct contact by trained personnel increased participation rate compared with mailed-letter methods. The positive effect appeared restricted to women with lower educational levels. Copyright 2001 American Health Foundation and Academic Press.

  12. 77 FR 41370 - Proposed Information Collection; Comment Request; 2013 Alternative Contact Strategy Test

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-07-13

    ... Alternative Contact Strategy Test AGENCY: U.S. Census Bureau, Commerce. ACTION: Notice. SUMMARY: The...-response. This research will be conducted through a series of projects and tests throughout the decade... 2013 Alternative Contact Strategy Test is the first test to support this research. The Census Bureau...

  13. The transport phase of pyrolytic oil exiting a fast fluidized bed reactor

    NASA Astrophysics Data System (ADS)

    Daugaard, Daren Einar

    An unresolved and debated aspect in the fast pyrolysis of biomass is whether the bio-oil exits as a vapor or as an aerosol from the pyrolytic reactor. The determination of the bio-oil transport phase will have direct and significant impact on the design of fast pyrolysis systems. Optimization of both the removal of particulate matter and collection of bio-oil will require this information. In addition, the success of catalytic reforming of bio-oil to high-value chemicals will depend upon this transport phase. A variety of experimental techniques were used to identify the transport phase. Some tests were as simple as examining the catch of an inline filter while others attempted to deduce whether vapor or aerosol predominated by examining the pressure drop across a flow restriction. In supplementary testing, the effect of char on aerosol formation and the potential impact of cracking during direct contact filtering are evaluated. The study indicates that for pyrolysis of red oak approximately 90 wt-% of the collected bio-oil existed as a liquid aerosol. Conversely, the pyrolysis of corn starch produced bio-oil predominately in the vapor phase at the exit of the reactor. Furthermore, it was determined that the addition of char promotes the production of aerosols during pyrolysis of corn starch. Direct contact filtering of the product stream did not collect any liquids and the bio-oil yield was not significantly reduced indicating measurable cracking or coking did not occur.

  14. Preparation of novel poly(vinylidene fluoride)/TiO2 photocatalysis membranes for use in direct contact membrane distillation

    NASA Astrophysics Data System (ADS)

    Li, Yukun; Dong, Shuying; Zhu, Liang

    2018-03-01

    Immobilization of TiO2 is a potential approach to obtain photocatalytic membranes that could eliminate concentration polarization in sewage disposal for direct contact membrane distillation (DCMD) process. A simple non-solvent-induced phase separation (NIPS) method was proposed to prepare poly(vinylidene fluoride) (PVDF) membrane, and the double-coating technology was further used to prepare the self-cleaning membranes with different TiO2 content. The effects of TiO2 nano-particles on membrane crystal form, morphology, porosity, pore size, pore size distribution, hydrophobicity, permeation, and photocatalytic efficiency were investigated, respectively. The flux of the prepared membranes is higher than the membrane (MS) provided by Membrane Solutions, LLC, in DCMD process. The contact angle between water and membrane could be increased 22° by introducing photocatalytic layer containing TiO2. During the photocatalytic test, 65.78-96.31% degrading rate of 15 mg/L Rhodamine B (RhB) was achieved. The relative flux of the membrane T-3 can be recovered to 0.96 in photocatalysis-membrane reactor for 8 h UV radiation. The fabricated membrane has great potential in high-salty dyeing wastewater treatment due to its high hydrophobicity and photocatalytic capability. [Figure not available: see fulltext.

  15. Intraspecific Signals Inducing Aggregation in Periplaneta americana (Insecta: Dictyoptera).

    PubMed

    Imen, Saïd; Christian, Malosse; Virginie, Durier; Colette, Rivault

    2015-06-01

    Chemical communication is necessary to induce aggregation and to maintain the cohesion of aggregates in Periplaneta americana (L.) cockroaches. We aimed to identify the chemical message inducing aggregation in this species. Two types of bioassays were used-binary choice tests in Petri dishes and tests in Y-olfactometer. Papers conditioned by direct contact of conspecifics induce aggregation when proposed in binary choice tests and were attractive in a Y-olfactometer. The identification of the molecules present on these conditioned papers indicated that dichloromethane extracts contained mainly cuticular hydrocarbons whereas methanol extracts contained more volatile molecules. Only a mixture of extracts in both solvents induced aggregation. High concentrations of cuticular hydrocarbons are necessary to induce aggregation when presented alone. When presented with volatile molecules present in methanol extracts, low concentrations of cuticular hydrocarbons are sufficient to induce aggregation if they are presented in contact. Among volatile molecules collected on filter paper, a mixture of three compounds-hexadecanoic acid, pentadecanoic acid, and pentaethylene glycol-induced aggregation. Our results provide evidence that aggregation processes in P. americana relies on a dual mechanism: attraction over long distances by three volatile molecules and maintenance on site by contact with cuticular hydrocarbons. © The Authors 2015. Published by Oxford University Press on behalf of Entomological Society of America. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Gross anatomy education for South African undergraduate physiotherapy students.

    PubMed

    Shead, Dorothy A; Roos, Ronel; Olivier, Benita; Ihunwo, Amadi O

    2018-01-16

    Eight faculties in South Africa offer undergraduate physiotherapy training with gross anatomy included as a basis for clinical practice. Little information exists about anatomy education for this student body. A 42-question peer-reviewed survey was distributed to physiotherapy gross anatomy course coordinators in all the eight faculties. Seven coordinators from six (75%) of the universities responded. Two respondents' data from the same university were pooled. Collected data show that staff qualifications and experience varied widely and high to average staff to student ratios exist between faculties. Direct anatomy teaching duration was 12.3 (SD ±5.2) weeks per semester. Total number of weeks in courses per faculty was 27.6 (SD ±5.7) varying widely between institutions. Calculable direct contact anatomy hours ranged between 100 and 308 with a mean of 207.6 (SD ±78.1). Direct contact hours in lectures averaged 3.9 (SD ±1.6) per week and the average direct contact hours in practical sessions were 3.5 (SD ±1.8) per week. Dissection, prosection, plastinated models, surface anatomy, and e-learning were available across faculties. Ancillary modalities such as vertical integration and inter-professional learning were in use. All faculties had multiple-choice questions, spot tests, and short examination questions. Half had viva-voce examinations and one had additional long questions assessment. Students evaluated teaching performance in five faculties. Four faculties were reviewing anatomy programs to consider implementing changes to anatomy curriculum or pedagogy. The findings highlighted disparity between programs and also identified the need for specific guidelines to develop a unified South African gross anatomy course for physiotherapy students. Anat Sci Educ. © 2018 American Association of Anatomists. © 2018 American Association of Anatomists.

  17. Cadherin-11 Mediates Contact Inhibition of Locomotion during Xenopus Neural Crest Cell Migration

    PubMed Central

    Becker, Sarah F. S.; Mayor, Roberto; Kashef, Jubin

    2013-01-01

    Collective cell migration is an essential feature both in embryonic development and cancer progression. The molecular mechanisms of these coordinated directional cell movements still need to be elucidated. The migration of cranial neural crest (CNC) cells during embryogenesis is an excellent model for collective cell migration in vivo. These highly motile and multipotent cells migrate directionally on defined routes throughout the embryo. Interestingly, local cell-cell interactions seem to be the key force for directionality. CNC cells can change their migration direction by a repulsive cell response called contact inhibition of locomotion (CIL). Cell protrusions collapse upon homotypic cell-cell contact and internal repolarization leads to formation of new protrusions toward cell-free regions. Wnt/PCP signaling was shown to mediate activation of small RhoGTPase RhoA and inhibition of cell protrusions at the contact side. However, the mechanism how a cell recognizes the contact is poorly understood. Here, we demonstrate that Xenopus cadherin-11 (Xcad-11) mediated cell-cell adhesion is necessary in CIL for directional and collective migration of CNC cells. Reduction of Xcad-11 adhesive function resulted in higher invasiveness of CNC due to loss of CIL. Additionally, transplantation analyses revealed that CNC migratory behaviour in vivo is non-directional and incomplete when Xcad-11 adhesive function is impaired. Blocking Wnt/PCP signaling led to similar results underlining the importance of Xcad-11 in the mechanism of CIL and directional migration of CNC. PMID:24392028

  18. Crepidula Slipper Limpets Alter Sex Change in Response to Physical Contact with Conspecifics.

    PubMed

    Carrillo-Baltodano, Allan; Collin, Rachel

    2015-12-01

    Chemical signaling, especially signaling with waterborne cues, is an important mode of communication between conspecifics of aquatic organisms. Although conspecific associations play an important role in sex allocation of sequential hermaphroditic slipper limpets, the mode of signaling is unknown. We tested the hypothesis that the effects of conspecifics on animal size and time of sex change in the tropical slipper limpet Crepidula cf. marginalis are mediated by waterborne cues. In our experiment, pairs of snails (one small and one large) were kept in cups, either together or partitioned off with fine or coarse mesh, or partitioned, but switched from side to side to allow contact with the cup mate's pedal mucus. The larger snails that were allowed contact with the smaller companions grew faster, and generally changed sex sooner, than did the larger snails in the barrier treatments, which allowed no physical contact. The smaller snails that were allowed contact with the larger cup mate delayed sex change compared to those separated from their cup mates. We were, therefore, able to reject the hypothesis that waterborne cues mediate communication between these snails. Our results suggest that the cue that affects size and time to sex change requires some kind of physical interaction that is lost when the snails are separated. Furthermore, contact with another snail's pedal mucus does not compensate for the loss of physical contact. Since males often attach to the shell of larger females, direct contact may mediate this kind of physical interaction via positional information, physical stimulation, or contact-based chemical communication. Whatever the cue, contact with conspecifics influences both partners, resulting in, surprisingly, a higher growth rate in the larger animal and delayed sex change in the smaller animal. © 2015 Marine Biological Laboratory.

  19. Measurement of contact-angle hysteresis for droplets on nanopillared surface and in the Cassie and Wenzel states: a molecular dynamics simulation study.

    PubMed

    Koishi, Takahiro; Yasuoka, Kenji; Fujikawa, Shigenori; Zeng, Xiao Cheng

    2011-09-27

    We perform large-scale molecular dynamics simulations to measure the contact-angle hysteresis for a nanodroplet of water placed on a nanopillared surface. The water droplet can be in either the Cassie state (droplet being on top of the nanopillared surface) or the Wenzel state (droplet being in contact with the bottom of nanopillar grooves). To measure the contact-angle hysteresis in a quantitative fashion, the molecular dynamics simulation is designed such that the number of water molecules in the droplets can be systematically varied, but the number of base nanopillars that are in direct contact with the droplets is fixed. We find that the contact-angle hysteresis for the droplet in the Cassie state is weaker than that in the Wenzel state. This conclusion is consistent with the experimental observation. We also test a different definition of the contact-angle hysteresis, which can be extended to estimate hysteresis between the Cassie and Wenzel state. The idea is motivated from the appearance of the hysteresis loop typically seen in computer simulation of the first-order phase transition, which stems from the metastability of a system in different thermodynamic states. Since the initial shape of the droplet can be controlled arbitrarily in the computer simulation, the number of base nanopillars that are in contact with the droplet can be controlled as well. We show that the measured contact-angle hysteresis according to the second definition is indeed very sensitive to the initial shape of the droplet. Nevertheless, the contact-angle hystereses measured based on the conventional and new definition seem converging in the large droplet limit. © 2011 American Chemical Society

  20. Simulation of between-farm transmission of porcine reproductive and respiratory syndrome virus in Ontario, Canada using the North American Animal Disease Spread Model.

    PubMed

    Thakur, Krishna K; Revie, Crawford W; Hurnik, Daniel; Poljak, Zvonimir; Sanchez, Javier

    2015-03-01

    Porcine reproductive and respiratory syndrome (PRRS), a viral disease of swine, has major economic impacts on the swine industry. The North American Animal Disease Spread Model (NAADSM) is a spatial, stochastic, farm level state-transition modeling framework originally developed to simulate highly contagious and foreign livestock diseases. The objectives of this study were to develop a model to simulate between-farm spread of a homologous strain of PRRS virus in Ontario swine farms via direct (animal movement) and indirect (sharing of trucks between farms) contacts using the NAADSM and to compare the patterns and extent of outbreak under different simulated conditions. A total of 2552 swine farms in Ontario province were allocated to each census division of Ontario and geo-locations of the farms were randomly generated within the agriculture land of each Census Division. Contact rates among different production types were obtained using pig movement information from four regions in Canada. A total of 24 scenarios were developed involving various direct (movement of infected animals) and indirect (pig transportation trucks) contact parameters in combination with alternating the production type of the farm in which the infection was seeded. Outbreaks were simulated for one year with 1000 replications. The median number of farms infected, proportion of farms with multiple outbreaks and time to reach the peak epidemic were used to compare the size, progression and extent of outbreaks. Scenarios involving spread only by direct contact between farms resulted in outbreaks where the median percentage of infected farms ranged from 31.5 to 37% of all farms. In scenarios with both direct and indirect contact, the median percentage of infected farms increased to a range from 41.6 to 48.6%. Furthermore, scenarios with both direct and indirect contact resulted in a 44% increase in median epidemic size when compared to the direct contact scenarios. Incorporation of both animal movements and the sharing of trucks within the model indicated that the effect of direct and indirect contact may be nonlinear on outbreak progression. The increase of 44% in epidemic size when indirect contact, via sharing of trucks, was incorporated into the model highlights the importance of proper biosecurity measures in preventing transmission of the PRRS virus. Simulation of between-farm spread of the PRRS virus in swine farms has highlighted the relative importance of direct and indirect contact and provides important insights regarding the possible patterns and extent of spread of the PRRS virus in a completely susceptible population with herd demographics similar to those found in Ontario, Canada. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. Properties of perpendicular-anisotropy magnetic tunnel junctions fabricated over the bottom electrode contact

    NASA Astrophysics Data System (ADS)

    Miura, Sadahiko; Honjo, Hiroaki; Kinoshita, Keizo; Tokutome, Keiichi; Koike, Hiroaki; Ikeda, Shoji; Endoh, Tetsuo; Ohno, Hideo

    2015-04-01

    Perpendicular-anisotropy magnetic tunnel junctions (MTJs) were prepared on four substrate geometries, i.e., directly on the axis of the bottom electrode contact, directly off the axis of the bottom electrode contact, on the axis of the bottom electrode contact with a polished bottom electrode, and off the axis of the bottom electrode contact with a polished bottom electrode. Electrical shorts were observed for direct on-axis geometry at a certain extent, whereas there were no electrical shorts for the other three geometries. The MR ratio/σR, JC0, and thermal stability factor of the devices for polish on-axis geometry were almost the same as those for polish off-axis geometry. From TEM observations of the polish on-axis device, the interface between the bottom contact and the base electrode was determined to be rough, whereas the MgO barrier layer was determined to be smooth, indicating that the polish process was effective for smooth magnetic tunnel junction fabrication over the bottom contact. MTJs for polish on-axis geometry eliminated the base electrode resistance and increased the magnetoresistance ratio. This technology contributes to the higher density of spin transfer torque magnetic random access memory.

  2. The pathogenesis of highly virulent African Swine Fever virus in domestic pigs exposed via intraoropharyngeal, intranasopharyngeal, and intramuscular inoculation, and by direct contact with infected pigs

    USDA-ARS?s Scientific Manuscript database

    In order to optimize novel systems for African Swine Fever Virus (ASFV) vaccine development, domestic pigs were challenged with the highly virulent ASFV-Malawi strain via intraoropharyngeal (IOP), intranasopharyngeal (INP), intramuscular (IM), and direct contact (DC) routes. Direct challenge doses ...

  3. [The effects of social networks on health check-up service use among pre-frail older adults (candidate so-called "specified elderly individuals") compared with older people in general].

    PubMed

    Sugisawa, Hidehiro; Sugihara, Yoko

    2011-09-01

    Nursing care prevention programs cannot accomplish their goals without effective screening of pre-frail older people. Health check-up services provide a very opportunity for this purpose. In the present study we examined not only the direct and indirect effects of social networks on check-up service use among candidate pre-frail older people, but also whether these effects differ from those among older people in general. Subjects for this study were respondents of a survey for probability sampled aged 65 and over living in a city, Tokyo. Individuals who gave effective responses to items used in our analysis made up 55.8 percent of the sample. 734 candidate pre-frail older people were selected using the screening criteria provided by the ministry of Heath, Labor and Welfare. The general category of older people numbered 2,057, excluding the candidates and elderly certified for long-term care. Social networks were measured from five aspects: family size; contact with children or relatives living separately; contact with neighbors or friends; involvement in community activities; and seeing a doctor. Our model of indirect effects of social networks on check-up use included awareness of nursing care prevention programs as a mediating factor. Information about whether the subjects used the health check-up service was provided.by the regional government. Magnitude of the effects was evaluated from two aspects; using statistical tests and focusing on marginal effects. Although none of the social network indicators had direct significant impacts on check-up use, contact with children or relatives living separately, contact with neighbors or friends, or involvement with community activities demonstrated significant indirect influence. Contact with neighbors or friends, involvement with community activities, or seeing a doctor had direct significant effects on use among the general category of older people, but none of the social network indicators demonstrated significant indirect effects. Involvement with community activities had the strongest total (direct plus indirect) effects on the use in the social networks indicators among the candidates when viewed with the focus on marginal effects. However, it was estimated that the rate of use would raise only about 5 percent even if average frequency of contacts with community activities were to increase from less than one time to one time over a month among the candidates. It is suggested that effects of social networks on health check-up service use among candidates of pre-frail older people could be produced by improving awareness of nursing care prevention programs.

  4. Design, methods, and participant characteristics of the Impact of Personal Genomics (PGen) Study, a prospective cohort study of direct-to-consumer personal genomic testing customers.

    PubMed

    Carere, Deanna Alexis; Couper, Mick P; Crawford, Scott D; Kalia, Sarah S; Duggan, Jake R; Moreno, Tanya A; Mountain, Joanna L; Roberts, J Scott; Green, Robert C

    2014-01-01

    Designed in collaboration with 23andMe and Pathway Genomics, the Impact of Personal Genomics (PGen) Study serves as a model for academic-industry partnership and provides a longitudinal dataset for studying psychosocial, behavioral, and health outcomes related to direct-to-consumer personal genomic testing (PGT). Web-based surveys administered at three time points, and linked to individual-level PGT results, provide data on 1,464 PGT customers, of which 71% completed each follow-up survey and 64% completed all three surveys. The cohort includes 15.7% individuals of non-white ethnicity, and encompasses a range of income, education, and health levels. Over 90% of participants agreed to re-contact for future research.

  5. Direct Test for Neuroinflammation with [11C]DAP-713-PET Scanning

    DTIC Science & Technology

    2015-10-01

    individuals suffering from the Gulf War Illness (GWI). We are using quantitative positron emission tomography (PET) using [11C]DPA-713 (DPA). DPA...suffering from the Gulf War Illness (GWI). We are using quantitative positron emission tomography (PET) using [11C]DPA-713 (DPA). DPA binds to the... Resistant Prostate Cancer Time commitments: 0.12 calendar months Supporting Agency: CDMRP Grants Contact: TBD PI: Denmeade Co-Investigator

  6. Assessing the Risk of Inadvertent Nuclear War Between India and Pakistan

    DTIC Science & Technology

    2002-12-01

    stories/review.htm>. 5 avoided partly as a result of this. Hundreds of nuclear weapons tests were conducted, proving the technical capability of...sites in Cuba. The results of such an attack could have been disastrous, putting conventional systems in direct contact with nuclear systems, and... nuclear weapons and their delivery systems. Finally, India and Pakistan’s nuclear doctrines are compared. These comparisons yield important results

  7. Laser based spot weld characterization

    NASA Astrophysics Data System (ADS)

    Jonietz, Florian; Myrach, Philipp; Rethmeier, Michael; Suwala, Hubert; Ziegler, Mathias

    2016-02-01

    Spot welding is one of the most important joining technologies, especially in the automotive industry. Hitherto, the quality of spot welded joints is tested mainly by random destructive tests. A nondestructive testing technique offers the benefit of cost reduction of the testing procedure and optimization of the fabrication process, because every joint could be examined. This would lead to a reduced number of spot welded joints, as redundancies could be avoided. In the procedure described here, the spot welded joint between two zinc-coated steel sheets (HX340LAD+Z100MB or HC340LA+ZE 50/50) is heated optically on one side. Laser radiation and flash light are used as heat sources. The melted zone, the so called "weld nugget" provides the mechanical stability of the connection, but also constitutes a thermal bridge between the sheets. Due to the better thermal contact, the spot welded joint reveals a thermal behavior different from the surrounding material, where the heat transfer between the two sheets is much lower. The difference in the transient thermal behavior is measured with time resolved thermography. Hence, the size of the thermal contact between the two sheets is determined, which is directly correlated to the size of the weld nugget, indicating the quality of the spot weld. The method performs well in transmission with laser radiation and flash light. With laser radiation, it works even in reflection geometry, thus offering the possibility of testing with just one-sided accessibility. By using heating with collimated laser radiation, not only contact-free, but also remote testing is feasible. A further convenience compared to similar thermographic approaches is the applicability on bare steel sheets without any optical coating for emissivity correction. For this purpose, a proper way of emissivity correction was established.

  8. Fabrication of Multilayer-Type Mn-Si Thermoelectric Device

    NASA Astrophysics Data System (ADS)

    Kajitani, T.; Ueno, T.; Miyazaki, Y.; Hayashi, K.; Fujiwara, T.; Ihara, R.; Nakamura, T.; Takakura, M.

    2014-06-01

    This research aims to develop a direct-contact manganese silicon p/ n multilayer-type thermoelectric power generation block. p-type MnSi1.74 and n-type Mn0.7Fe0.3Si1.68 ball-milled powders with diameter of about 10 μm or less were mixed with polyvinyl butyl alcohol diluted with methylbenzene at pigment volume concentration of approximately 70%. The doctor-blade method produced 45- μm-thick p- and n-type pigment plates. The insulator, i.e., powdered glass, was mixed with cellulose to form insulator slurry. Lamination of manganese silicide pigment layers and screen-printed insulator layers was carried out to fabricate multilayer direct-contact thermoelectric devices. Hot pressing and spark plasma sintering were carried out at 450°C and 900°C, respectively. Four to 30 thermoelectric (TE) p/ n pairs were fabricated in a 10 mm × 10 mm × 10 mm sintered TE block. The maximum output was 11.7 mW/cm2 at a temperature difference between 20°C and 700°C, which was about 1/85 of the ideal power generation estimated from the thermoelectric data of the bulk MnSi1.74 and Mn0.7Fe0.3Si1.68 materials. A power generation test using an engine test bench was also carried out.

  9. Effect of direct and indirect contact with mental illness on dangerousness and social distance.

    PubMed

    Lee, Minhwa; Seo, Mikyung

    2018-03-01

    This study is based on the contact hypothesis that contact with mental illness is the most effective anti-stigma strategy. This study aims to analyze which form of contact can most effectively decrease the dangerousness and social distance associated with schizophrenia, depression and alcoholism. In total, 573 Korean adults ( M age  = 43.71 years, standard deviation ( SD) = 13.41; 54.1% male, 45.9% female) were surveyed about randomly assigned vignettes of schizophrenia, depression and alcoholism. The participants were questioned on the dangerousness and social distance associated with the assigned vignette, as well as direct and indirect contact experience with the mental illness. Two-way analysis of variance (ANOVA) was used to determine the main effect and interaction effect that the type of mental illness and contact experience have on the two dependent variables (dangerousness and social distance). The findings show that the type of mental illness has a significant main effect on dangerousness and social distance, but contact type only has a significant main effect on social distance. Moreover, the two independent variables (mental illness subtype and contact experience) have an interaction effect on two dependent variables (dangerousness and social distance). Therefore, the anti-stigma effect of contact varies according to the type of mental illness. Our findings suggest that appropriate anti-stigma strategies are required for each type of mental illness. Considering that opportunities for direct contact with persons with mental illness are highly limited, it is necessary to actively utilize indirect contact.

  10. [Effect of the vacuum-formed retainer on preventing the proximal contact loss between implant supported crown and adjacent natural teeth].

    PubMed

    Zeng, B J; Guo, Y; Yu, R Y

    2018-06-18

    To evaluate the effect of the vacuum-formed retainer on preventing the proximal contact loss between the implant supported crown and its adjacent natural teeth. Forty-six posterior implant crowns in the mandible including 92 interproximal contacts in 46 patients (19 men, 27 women) aged from 25 to 66 years were included. The participants in experimental group (22 cases) were vacuum-formed retainers at night, while participants in control group (24 cases) only received routine examination. The two groups were not different in age, gender, the time interval of the tooth loss and tooth position at baseline. Mesial and distal proximal contact tightness was measured using the orthodontic dynamometer and metallic articulating film immediately after crown delivery, and 1-month, 3-month, 6-month, and 1-year follow-up respectively. The articulating film was inserted interdentally from the occlusal direction, and then it was slowly removed in the buccallingual direction by the dynamometer. Increasing the number of films (N) piece by piece until the frictional force (F) was great than 0, and the number of films (N) was recorded. At each follow-up, proximal contact between implant crown and its adjacent teeth was considered to be loss if the number of films (N) used at immediate crown delivery passed without frictional force (F=0). Besides, the periodontal conditions [scored according to the probing depth (PD), bleeding index (BI), mobility (M)] and complaint of food impaction were recorded. The mesial and distal proximal contact loss rates were compared between the two groups at different times. Chi-square test or Fisher's exact test was used for statistical analysis. The proximal contact loss rate on the mesial surface of the implant supported crown continuously increased over the follow-up periods. At the end of the 1-, 3-, and 6-month follow ups, 18.2%, 22.7% and 27.3% were identified for the contact loss rates on the mesial surface of the implant supported crown in the experimental group, respectively. Meanwhile in control group, the rates were 20.8%, 37.5% and 45.8%. No significant differences were observed at the end of the 1-, 3-, and 6-month follow ups(1-month: χ 2 =0.000, P=1.000; 3-month: χ 2 =1.183, P=0.277; 6-month: χ 2 =1.697, P=0.193). The proximal contact loss rate on the mesial surface in control group (62.5%) was significantly higher than that in the experimental group (31.8%, χ 2 =4.330, P=0.037) at the end of the 1-year follow-up. However, no statistical difference was found on the distal surfaces between the two groups during the whole follow-up periods. The first open contact was noted 1 month after crown insertion. By wearing vacuum-formed retainer for one year, the incidence of open contacts between the posterior implant prostheses and mesial adjacent teeth in the mandible has been reduced.

  11. Comparison of analysis and experiment for dynamics of low-contact-ratio spur gears

    NASA Technical Reports Server (NTRS)

    Oswald, Fred B.; Rebbechi, Brian; Zakrajsek, James J.; Townsend, Dennis P.; Lin, Hsiang Hsi

    1991-01-01

    Low-contact-ratio spur gears were tested in NASA gear-noise-rig to study gear dynamics including dynamic load, tooth bending stress, vibration, and noise. The experimental results were compared with a NASA gear dynamics code to validate the code as a design tool for predicting transmission vibration and noise. Analytical predictions and experimental data for gear-tooth dynamic loads and tooth-root bending stress were compared at 28 operating conditions. Strain gage data were used to compute the normal load between meshing teeth and the bending stress at the tooth root for direct comparison with the analysis. The computed and measured waveforms for dynamic load and stress were compared for several test conditions. These are very similar in shape, which means the analysis successfully simulates the physical behavior of the test gears. The predicted peak value of the dynamic load agrees with the measurement results within an average error of 4.9 percent except at low-torque, high-speed conditions. Predictions of peak dynamic root stress are generally within 10 to 15 percent of the measured values.

  12. Protecting Yourself From Shingles | NIH MedlinePlus the Magazine

    MedlinePlus

    ... with shingles can spread the disease through direct contact with the rash when the rash is in the blister phase. ... person who has never had chickenpox through direct contact with the rash. The person exposed would develop chickenpox, not shingles. ...

  13. A Comparison between Antibacterial Activity of Propolis and Aloe vera on Enterococcus faecalis (an In Vitro Study).

    PubMed

    Ehsani, Maryam; Amin Marashi, Mahmood; Zabihi, Ebrahim; Issazadeh, Maryam; Khafri, Soraya

    2013-01-01

    Removing the bacteria, including Enterococcus faecalis, from the root canal is one of the important aims in endodontic treatment.We aimed to compare the antibacterial activity of Chlorhexidine with two natural drugs. The antibacterial activities of three different propolis extracts (alcohol concentrations: 0, 15, 40%) and Aloe vera gel on E. faecalis were compared using three methods: disk diffusion, microdilution and direct contact test. In addition to the above bacterium, the Aloe vera gel effect on Staphylococcus aureus and Streptococcus mutans was evaluated. Disk diffusion test revealed that propolis ethanolic extracts (the alcohol concentration of 15 and 40%) and Aloe vera gel have antibacterial activities but aqueous extract of propolis did not show any effect in this test. The MICs for propolis ethanolic extracts, Aloe vera gel and aqueous extract of propolis (0% alcohol) were 313 µg/ml, 750 µg/ml, 2250 µg/ml, and ≥ 500 µg/ml respectively, much higher than the Chlorhexidine one. In direct contact test, contrary to Aloe vera, all three propolis extracts showed antibacterial effects on E. faecalis. The Aloe vera gel also showed significant antibacterial effect on S.aureus and S.mutans. The hydroalcoholic extracts of propolis and Aloe vera gel had antibacterial effects on E. faecalis, however, propolis is more potent than Aloe vera. The antibacterial effect of Aloe vera on S. aureus and S. mutans is low (MIC ≥ 2250 µg/ml). Appropriate concentrations of alcoholic extracts of propolis and some fractions of Aloe vera gel might be good choices for disinfecting the root canal in endodontic treatments.

  14. PAH toxicity at aqueous solubility in the fish embryo test with Danio rerio using passive dosing.

    PubMed

    Seiler, Thomas-Benjamin; Best, Nina; Fernqvist, Margit Møller; Hercht, Hendrik; Smith, Kilian E C; Braunbeck, Thomas; Mayer, Philipp; Hollert, Henner

    2014-10-01

    As part of the risk assessment process within REACh, prior to manufacturing and distribution of chemical substances their (eco)toxicological impacts have to be investigated. The fish embryo toxicity test (FET) with the zebrafish Danio rerio has gained a high significance as an in vitro alternative to animal testing in (eco)toxicology. However, for hydrophobic organic chemicals it remains a technical challenge to ensure constant freely dissolved concentration at the maximum exposure level during such biotests. Passive dosing with PDMS silicone was thus applied to control the freely dissolved concentration of ten PAHs at their saturation level in the FET. The experiments gave repeatable results, with the toxicity of the PAHs generally increasing with the maximum chemical activities of the PAHs. HPLC analysis confirmed constant exposure at the saturation level. In additional experiments, fish embryos without direct contact to the silicone surface showed similar mortalities as those exposed with direct contact to the silicone. Silicone oil overlaying the water phase as a novel passive dosing phase had no observable effects on the development of the fish embryos until hatching. This study provides further data to support the close relationship between the chemical activity and the toxicity of hydrophobic organic compounds. Passive dosing from PDMS silicone enabled reliable toxicity testing of (highly) hydrophobic substances at aqueous solubility, providing a practical way to control toxicity exactly at the maximum exposure level. This approach is therefore expected to be useful as a cost-effective initial screening of hydrophobic chemicals for potential adverse effects to freshwater vertebrates. Copyright © 2014 Elsevier Ltd. All rights reserved.

  15. Fluid to fluid contact heat exchanger

    NASA Technical Reports Server (NTRS)

    Clark, W. E.

    1986-01-01

    Heat transfer and pressure drop test results for a fluid to fluid contact heat exchanger are reported. The heat exchanger, fabricated and tested to demonstrate one method of transferring heat between structures in space, had a total contact area of 0.18 sq m. It utilized contact surfaces which were flexible and conformed to the mating contact surfaces upon pressurization of the fluid circulating within the heat exchanger. During proof-of-concept performance tests, the heat exchanger was operated in a typical earth environment. It demonstrated a contact conductance of 3.8 kW/sq m C at contact pressures in the 15 to 70 kPa range.

  16. Integrating water exclusion theory into βcontacts to predict binding free energy changes and binding hot spots

    PubMed Central

    2014-01-01

    Background Binding free energy and binding hot spots at protein-protein interfaces are two important research areas for understanding protein interactions. Computational methods have been developed previously for accurate prediction of binding free energy change upon mutation for interfacial residues. However, a large number of interrupted and unimportant atomic contacts are used in the training phase which caused accuracy loss. Results This work proposes a new method, βACV ASA , to predict the change of binding free energy after alanine mutations. βACV ASA integrates accessible surface area (ASA) and our newly defined β contacts together into an atomic contact vector (ACV). A β contact between two atoms is a direct contact without being interrupted by any other atom between them. A β contact’s potential contribution to protein binding is also supposed to be inversely proportional to its ASA to follow the water exclusion hypothesis of binding hot spots. Tested on a dataset of 396 alanine mutations, our method is found to be superior in classification performance to many other methods, including Robetta, FoldX, HotPOINT, an ACV method of β contacts without ASA integration, and ACV ASA methods (similar to βACV ASA but based on distance-cutoff contacts). Based on our data analysis and results, we can draw conclusions that: (i) our method is powerful in the prediction of binding free energy change after alanine mutation; (ii) β contacts are better than distance-cutoff contacts for modeling the well-organized protein-binding interfaces; (iii) β contacts usually are only a small fraction number of the distance-based contacts; and (iv) water exclusion is a necessary condition for a residue to become a binding hot spot. Conclusions βACV ASA is designed using the advantages of both β contacts and water exclusion. It is an excellent tool to predict binding free energy changes and binding hot spots after alanine mutation. PMID:24568581

  17. R2C: improving ab initio residue contact map prediction using dynamic fusion strategy and Gaussian noise filter.

    PubMed

    Yang, Jing; Jin, Qi-Yu; Zhang, Biao; Shen, Hong-Bin

    2016-08-15

    Inter-residue contacts in proteins dictate the topology of protein structures. They are crucial for protein folding and structural stability. Accurate prediction of residue contacts especially for long-range contacts is important to the quality of ab inito structure modeling since they can enforce strong restraints to structure assembly. In this paper, we present a new Residue-Residue Contact predictor called R2C that combines machine learning-based and correlated mutation analysis-based methods, together with a two-dimensional Gaussian noise filter to enhance the long-range residue contact prediction. Our results show that the outputs from the machine learning-based method are concentrated with better performance on short-range contacts; while for correlated mutation analysis-based approach, the predictions are widespread with higher accuracy on long-range contacts. An effective query-driven dynamic fusion strategy proposed here takes full advantages of the two different methods, resulting in an impressive overall accuracy improvement. We also show that the contact map directly from the prediction model contains the interesting Gaussian noise, which has not been discovered before. Different from recent studies that tried to further enhance the quality of contact map by removing its transitive noise, we designed a new two-dimensional Gaussian noise filter, which was especially helpful for reinforcing the long-range residue contact prediction. Tested on recent CASP10/11 datasets, the overall top L/5 accuracy of our final R2C predictor is 17.6%/15.5% higher than the pure machine learning-based method and 7.8%/8.3% higher than the correlated mutation analysis-based approach for the long-range residue contact prediction. http://www.csbio.sjtu.edu.cn/bioinf/R2C/Contact:hbshen@sjtu.edu.cn Supplementary data are available at Bioinformatics online. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  18. Multiple direction vibration fixture

    DOEpatents

    Cericola, Fred; Doggett, James W.; Ernest, Terry L.; Priddy, Tommy G.

    1991-01-01

    An apparatus for simulating a rocket launch environment on a test item undergoing centrifuge testing by subjecting the item simultaneously or separately to vibration along an axis of centripetal force and along an axis perpendicular to the centripetal force axis. The apparatus includes a shaker motor supported by centrifuge arms and a right angle fixture pivotally connected to one of the shaker motor mounts. When the shaker motor vibrates along the centripetal force axis, the vibrations are imparted to a first side of the right angle fixture. The vibrations are transmitted 90 degrees around the pivot and are directed to a second side of the right angle fixture which imparts vibrations perpendicular to the centripetal force axis. The test item is in contact with a third side of the right angle fixture and receives both centripetal-force-axis vibrations and perpendicular axis vibrations simultaneously. A test item can be attached to the third side near the flexible coupling or near the air bag to obtain vibrations along the centripetal force axis or transverse to the centripetal force axis.

  19. Attention to eye contact in the West and East: autonomic responses and evaluative ratings.

    PubMed

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level.

  20. Attention to Eye Contact in the West and East: Autonomic Responses and Evaluative Ratings

    PubMed Central

    Akechi, Hironori; Senju, Atsushi; Uibo, Helen; Kikuchi, Yukiko; Hasegawa, Toshikazu; Hietanen, Jari K.

    2013-01-01

    Eye contact has a fundamental role in human social interaction. The special appearance of the human eye (i.e., white sclera contrasted with a coloured iris) implies the importance of detecting another person's face through eye contact. Empirical studies have demonstrated that faces making eye contact are detected quickly and processed preferentially (i.e., the eye contact effect). Such sensitivity to eye contact seems to be innate and universal among humans; however, several studies suggest that cultural norms affect eye contact behaviours. For example, Japanese individuals exhibit less eye contact than do individuals from Western European or North American cultures. However, how culture modulates eye contact behaviour is unclear. The present study investigated cultural differences in autonomic correlates of attentional orienting (i.e., heart rate) and looking time. Additionally, we examined evaluative ratings of eye contact with another real person, displaying an emotionally neutral expression, between participants from Western European (Finnish) and East Asian (Japanese) cultures. Our results showed that eye contact elicited stronger heart rate deceleration responses (i.e., attentional orienting), shorter looking times, and higher ratings of subjective feelings of arousal as compared to averted gaze in both cultures. Instead, cultural differences in the eye contact effect were observed in various evaluative responses regarding the stimulus faces (e.g., facial emotion, approachability etc.). The rating results suggest that individuals from an East Asian culture perceive another's face as being angrier, unapproachable, and unpleasant when making eye contact as compared to individuals from a Western European culture. The rating results also revealed that gaze direction (direct vs. averted) could influence perceptions about another person's facial affect and disposition. These results suggest that cultural differences in eye contact behaviour emerge from differential display rules and cultural norms, as opposed to culture affecting eye contact behaviour directly at the physiological level. PMID:23516627

  1. Multigrid Methods for EHL Problems

    NASA Technical Reports Server (NTRS)

    Nurgat, Elyas; Berzins, Martin

    1996-01-01

    In many bearings and contacts, forces are transmitted through thin continuous fluid films which separate two contacting elements. Objects in contact are normally subjected to friction and wear which can be reduced effectively by using lubricants. If the lubricant film is sufficiently thin to prevent the opposing solids from coming into contact and carries the entire load, then we have hydrodynamic lubrication, where the lubricant film is determined by the motion and geometry of the solids. However, for loaded contacts of low geometrical conformity, such as gears, rolling contact bearings and cams, this is not the case due to high pressures and this is referred to as Elasto-Hydrodynamic Lubrication (EHL) In EHL, elastic deformation of the contacting elements and the increase in fluid viscosity with pressure are very significant and cannot be ignored. Since the deformation results in changing the geometry of the lubricating film, which in turn determines the pressure distribution, an EHL mathematical model must simultaneously satisfy the complex elasticity (integral) and the Reynolds lubrication (differential) equations. The nonlinear and coupled nature of the two equations makes numerical calculations computationally intensive. This is especially true for highly loaded problems found in practice. One novel feature of these problems is that the solution may exhibit sharp pressure spikes in the outlet region. To this date both finite element and finite difference methods have been used to solve EHL problems with perhaps greater emphasis on the use of the finite difference approach. In both cases, a major computational difficulty is ensuring convergence of the nonlinear equations solver to a steady state solution. Two successful methods for achieving this are direct iteration and multigrid methods. Direct iteration methods (e.g Gauss Seidel) have long been used in conjunction with finite difference discretizations on regular meshes. Perhaps one of the best examples of the application of such methods is the recent Effective Influence Method of Dowson and Wang. Multigrid methods have also been used with great success by Venner and Venner and Lubrecht with a good summary being given by Venner. As both these finite difference discretization based approaches appear to provide an efficient way of solving EHL problems, it is important to understand their relative merits. This paper is a first attempt at providing such an understanding in the context of EHL point contact problem, (contact of two spheres), in which the contact zone is a point and an ellipse or circle for unloaded and loaded dry contacts respectively. Since the film thickness and the contact width are generally small compared to the local radius of curvature of the two surfaces, the reduced geometry of the surfaces in the contact area can be accurately approximated to the contact between a paraboloid and a flat surface. The layout of the remainder of this paper is as follows. In section 2 we introduce the form of the equations to be solved. The Effective Influence Newton Method is described in Section 3 while Section 4 describes the Multigrid method to be used. Sections 5 and 6 describe the test problems to be used in the comparison between the two methods and compare the performance of the two methods. Section 7 concludes the paper with an argument of the two methods and suggests some future research directions.

  2. Rhinovirus antibodies in an isolated Amazon Indian tribe.

    PubMed

    Thwing, C J; Arruda, E; Vieira Filho, J P; Castelo Filho, A; Gwaltney, J M

    1993-06-01

    In early 1985, the Parakana-Apiterewa, a small, primitive Indian tribe, was contacted in the southern Amazon Basin. The tribe was thought to have been totally isolated from civilization until recent development of their land. Blood specimens were collected in 1985, shortly after the discovery of the tribe, and analyzed for the presence of rhinovirus-neutralizing antibody to nine different immunotypes. Six to forty-seven percent of the serum samples tested contained antibody to at least one immunotype of rhinovirus. The prevalence of rhinovirus antibody in the Parakana-Apiterewa Indians was similar to that reported in United States populations, suggesting that there had been considerable direct or indirect contact in the past between tribe members and persons in the outside world.

  3. The effect of lemon, orange and bergamot essential oils and their components on the survival of Campylobacter jejuni, Escherichia coli O157, Listeria monocytogenes, Bacillus cereus and Staphylococcus aureus in vitro and in food systems.

    PubMed

    Fisher, K; Phillips, C A

    2006-12-01

    To investigate the effectiveness of oils and vapours of lemon (Citrus limon), sweet orange (Citrus sinensis) and bergamot (Citrus bergamia) and their components against a number of common foodborne pathogens. The disc diffusion method was used to screen the oils and vapours against Listeria monocytogenes, Staphylococcus aureus, Bacillus cereus, Escherichia coli O157 and Campylobacter jejuni. The survival of each species, demonstrated to be susceptible in the in vitro studies, was tested on cabbage leaf for 60 s by direct contact and on chicken skin for 10 min by direct contact and 24 h by vapour. The results indicate that bergamot was the most inhibitory essential oil (EO) and citral and linalool mimicked its effect (P > 0.001). Citral and linalool vapours produced 6 log reductions in L. monocytogenes, Staph. aureus and B. cereus populations on cabbage leaf after 8-10 h exposure but bergamot vapour exposure, while producing a similar reduction in L. monocytogenes and B. cereus populations, had no effect on Staph. aureus. Bergamot was the most effective of the oils tested and linalool the most effective anti-bacterial component. Gram-positive bacteria were more susceptible than Gram-negative bacteria in vitro, although Camp. jejuni and E. coli O157 were inhibited by bergamot and linalool oils and by linalool vapour. All bacteria tested were less susceptible in food systems than in vitro. Of the Gram-positive bacteria tested Staph. aureus was the least susceptible to both the oils and the components tested. Results suggest the possibility that citrus EOs, particularly bergamot, could be used as a way of combating the growth of common causes of food poisoning.

  4. [USE OF QuantiFERON® TB-GOLD IN-TUBE IN A CONTACT INVESTIGATION TO DETERMINE THE ONSET OF TUBERCULOSIS WITH OR WITHOUT LATENT TUBERCULOSIS INFECTION TREATMENT].

    PubMed

    Matsumoto, Kenji; Komukai, Jun; Tsuda, Yuko; Furukawa, Kanae; Saito, Kazumi; Hirota, Satoshi; Koda, Shinichi; Kasai, Sachi; Shimouchi, Akira

    2016-02-01

    QuantiFERON® TB-Gold In-Tube (3G) testing was performed on tuberculosis-positive index cases and their contacts. The purpose of this study was to evaluate the relationship between 3G test results and the subsequent development of tuberculosis, and to identify effective strategies to prevent the onset of tuberculosis. Index cases and their contacts were subjected to 3G testing in a contact investigation in Osaka City in 2011-2012. For index cases, sputum smears were tested, and the infecting organism was identified. For the contacts, the following information was collected: age, results of 3G testing, presence or absence of latent tuberculosis infection (LTBI) treatment, and onset of tuberculosis disease within 2 years of follow-up from the last contact with the index cases. (1) There were 830 index cases, including 774 subjects with pulmonary tuberculosis (93.3%) and 3 with laryngeal tuberculosis (0.4%). From sputum smear tests, 726 patients (87.5%) were determined to be 3G positive, and 83 (10.0%) were determined to be 3G negative. (2) In total, 2,644 contacts were subjected to 3G testing. Of these, 2,072 patients (78.4%) tested negative, 196 (7.4%) showed an equivocal result, and 375 (14.2%) tested positive. Their mean ages were 33.7, 38.0, and 38.8 years, respectively, showing significant differences in tuberculosis status according to age (P < 0.001). (3) Among the 2,072 3G-negative contacts, tuberculosis developed in 2 (0.1%) of 2063. None of these contacts was treated for LTBI. Among the 375 3G-positive contacts, tuberculosis developed in 36 (36.0%) of 100 subjects that were not LTBI treated, while tuberculosis developed in 3 (1.1 %) of 275 subjects that were LTBI treated. A significant difference in the incidence of tuberculosis between treated and untreated 3G-positive contacts was observed (P < 0.001). Tuberculosis developed in a high proportion of 3G-positive contacts that were not LTBI treated, suggesting the need for preventive management of 3G-positive contacts.

  5. High voltage MOSFET devices and methods of making the devices

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+more » region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.« less

  6. High voltage MOSFET devices and methods of making the devices

    DOEpatents

    Banerjee, Sujit; Matocha, Kevin; Chatty, Kiran

    2015-12-15

    A SiC MOSFET device having low specific on resistance is described. The device has N+, P-well and JFET regions extended in one direction (Y-direction) and P+ and source contacts extended in an orthogonal direction (X-direction). The polysilicon gate of the device covers the JFET region and is terminated over the P-well region to minimize electric field at the polysilicon gate edge. In use, current flows vertically from the drain contact at the bottom of the structure into the JFET region and then laterally in the X direction through the accumulation region and through the MOSFET channels into the adjacent N+ region. The current flowing out of the channel then flows along the N+ region in the Y-direction and is collected by the source contacts and the final metal. Methods of making the device are also described.

  7. Training for eye contact modulates gaze following in dogs.

    PubMed

    Wallis, Lisa J; Range, Friederike; Müller, Corsin A; Serisier, Samuel; Huber, Ludwig; Virányi, Zsófia

    2015-08-01

    Following human gaze in dogs and human infants can be considered a socially facilitated orientation response, which in object choice tasks is modulated by human-given ostensive cues. Despite their similarities to human infants, and extensive skills in reading human cues in foraging contexts, no evidence that dogs follow gaze into distant space has been found. We re-examined this question, and additionally whether dogs' propensity to follow gaze was affected by age and/or training to pay attention to humans. We tested a cross-sectional sample of 145 border collies aged 6 months to 14 years with different amounts of training over their lives. The dogs' gaze-following response in test and control conditions before and after training for initiating eye contact with the experimenter was compared with that of a second group of 13 border collies trained to touch a ball with their paw. Our results provide the first evidence that dogs can follow human gaze into distant space. Although we found no age effect on gaze following, the youngest and oldest age groups were more distractible, which resulted in a higher number of looks in the test and control conditions. Extensive lifelong formal training as well as short-term training for eye contact decreased dogs' tendency to follow gaze and increased their duration of gaze to the face. The reduction in gaze following after training for eye contact cannot be explained by fatigue or short-term habituation, as in the second group gaze following increased after a different training of the same length. Training for eye contact created a competing tendency to fixate the face, which prevented the dogs from following the directional cues. We conclude that following human gaze into distant space in dogs is modulated by training, which may explain why dogs perform poorly in comparison to other species in this task.

  8. Estimating the Contact Endurance of the AISI 321 Stainless Steel Under Contact Gigacycle Fatigue Tests

    NASA Astrophysics Data System (ADS)

    Savrai, R. A.; Makarov, A. V.; Osintseva, A. L.; Malygina, I. Yu.

    2018-02-01

    Mechanical testing of the AISI 321 corrosion resistant austenitic steel for contact gigacycle fatigue has been conducted with the application of a new method of contact fatigue testing with ultrasonic frequency of loading according to a pulsing impact "plane-to-plane" contact scheme. It has been found that the contact endurance (the ability to resist the fatigue spalling) of the AISI 321 steel under contact gigacycle fatigue loading is determined by its plasticity margin and the possibility of additional hardening under contact loading. It is demonstrated that the appearance of localized deep and long areas of spalling on a material surface can serve as a qualitative characteristic for the loss of the fatigue strength of the AISI 321 steel under impact contact fatigue loading. The value of surface microhardness measured within contact spots and the maximum depth of contact damages in the peripheral zone of contact spots can serve as quantitative criteria for that purpose.

  9. Effects of Particle Size on the Shear Behavior of Coarse Grained Soils Reinforced with Geogrid.

    PubMed

    Kim, Daehyeon; Ha, Sungwoo

    2014-02-07

    In order to design civil structures that are supported by soils, the shear strength parameters of soils are required. Due to the large particle size of coarse-grained soils, large direct shear tests should be performed. In this study, large direct shear tests on three types of coarse grained soils (4.5 mm, 7.9 mm, and 15.9 mm) were performed to evaluate the effects of particle size on the shear behavior of coarse grained soils with/without geogrid reinforcements. Based on the direct shear test results, it was found that, in the case of no-reinforcement, the larger the maximum particle size became, the larger the friction angle was. Compared with the no-reinforcement case, the cases reinforced with either soft geogrid or stiff geogrid have smaller friction angles. The cohesion of the soil reinforced with stiff geogrid was larger than that of the soil reinforced with soft geogrid. The difference in the shear strength occurs because the case with a stiff geogrid has more soil to geogrid contact area, leading to the reduction in interlocking between soil particles.

  10. Noninvasive screening for genital chlamydial infections in asymptomatic men: Strategies and costs using a urine PCR assay

    PubMed Central

    Peeling, Rosanna W; Toye, Baldwin; Jessamine, Peter; Gemmill, Ian

    1998-01-01

    OBJECTIVE: To evaluate cost saving strategies to screen for genital chlamydial infection in men using polymerase chain reaction (PCR) technology. METHODS: Men with no urethral symptoms presenting to a sexually transmitted disease (STD) clinic were recruited. Study participants underwent a questionnaire interview. Urethral swabs were taken to perform a smear for polymorphonuclear leucocytes (PMN) and for the detection of Chlamydia trachomatis by culture and PCR. First-catch urine was collected for a leukocyte esterase test (LET) and PCR. RESULTS: C trachomatis infection was detected in 36 of 463 (7.8%) men. LET and PMN were positive in 10 (28%) and 12 (33%) infected men, respectively. Risk factors for chlamydial infection were younger than age 25 years, LET-positive, PMN-positive and STD contact (P<0.001). The direct cost of genital chlamydial infection in men in Canada has been previously estimated at $381/case. Based on a sensitivity of 90% for urine PCR, the estimated direct cost of testing all participants to detect 32 cases was $453/case. Using risk factors recommended in the Canadian STD Guidelines (age younger than 25 years, new partner, STD contact or unprotected sex), the same number of cases would have been detected by testing only 384 men at $376/case. Using age younger than 25 years or STD contact as the screening criterion, 78% of those infected would have been detected at $259/case, and no new cases would have been detected by adding LET-positive or PMN-positive as risk factors. CONCLUSION: Targeted screening for chlamydial infection using urine PCR assay and risk factors recommended in the Canadian guidelines could substantially reduce the cost of screening at a STD clinic setting. LET and PMN smear did not appear to be useful indicators of chlamydial infection in this population. PMID:22346549

  11. Three-dimensional culture of dental pulp stem cells in direct contact to tricalcium silicate cements.

    PubMed

    Widbiller, M; Lindner, S R; Buchalla, W; Eidt, A; Hiller, K-A; Schmalz, G; Galler, K M

    2016-03-01

    Calcium silicate cements are biocompatible dental materials applicable in contact with vital tissue. The novel tricalcium silicate cement Biodentine™ offers properties superior to commonly used mineral trioxide aggregate (MTA). Objective of this study was to evaluate its cytocompatibility and ability to induce differentiation and mineralization in three-dimensional cultures of dental pulp stem cells after direct contact with the material. Test materials included a new tricalcium silicate (Biodentine™, Septodont, Saint-Maur-des-Fossés, France), MTA (ProRoot® MTA, DENSPLY Tulsa Dental Specialities, Johnson City, TN, USA), glass ionomer (Ketac™ Molar Aplicap™, 3M ESPE, Seefeld, Germany), human dentin disks and polystyrene. Magnetic activated cell sorting for to the surface antigen STRO-1 was performed to gain a fraction enriched with mesenchymal stem cells. Samples were allowed to set and dental pulp stem cells in collagen carriers were placed on top. Scanning electron microscopy of tricalcium silicate cement surfaces with and without cells was conducted. Cell viability was measured for 14 days by MTT assay. Alkaline phosphatase activity was evaluated (days 3, 7, and 14) and expression of mineralization-associated genes (COL1A1, ALP, DSPP, and RUNX2) was quantified by real-time quantitative PCR. Nonparametric statistical analysis for cell viability and alkaline phosphatase data was performed to compare different materials as well as time points (Mann-Whitney U test, α = 0.05). Cell viability was highest on tricalcium silicate cement, followed by MTA. Viability on glass ionomer cement and dentin disks was significantly lower. Alkaline phosphatase activity was lower in cells on new tricalcium silicate cement compared to MTA, whereas expression patterns of marker genes were alike. Increased cell viability and similar levels of mineralization-associated gene expression in three-dimensional cell cultures on the novel tricalcium silicate cement and mineral trioxide aggregate indicate that the material is cytocompatible and bioactive. The tested new tricalcium silicate cement confirms its suitability as an alternative to MTA in vital pulp therapy.

  12. Effects of 2 ankle destabilization devices on electromyography measures during functional exercises in individuals with chronic ankle instability.

    PubMed

    Donovan, Luke; Hart, Joseph M; Hertel, Jay

    2015-03-01

    Randomized crossover laboratory study. To determine the effects of ankle destabilization devices on surface electromyography (sEMG) measures of selected lower extremity muscles during functional exercises in participants with chronic ankle instability. Ankle destabilization devices are rehabilitation tools that can be worn as a boot or sandal to increase lower extremity muscle activation during walking in healthy individuals. However, they have not been tested in a population with pathology. Fifteen adults with chronic ankle instability participated. Surface electromyography electrodes were located over the anterior tibialis, fibularis longus, lateral gastrocnemius, rectus femoris, biceps femoris, and gluteus medius. The activity level of these muscles was recorded in a single testing session during unipedal stance with eyes closed, the Star Excursion Balance Test, lateral hops, and treadmill walking. Each task was performed under 3 conditions: shod, ankle destabilization boot, and ankle destabilization sandal. Surface electromyography signal amplitudes were measured for each muscle during each exercise for all 3 conditions. Participants demonstrated a significant increase, with moderate to large effect sizes, in sEMG signal amplitude of the fibularis longus in the ankle destabilization boot and ankle destabilization sandal conditions during the unipedal eyes-closed balance test, the Star Excursion Balance Test in the anterior and posteromedial directions, lateral hops, and walking, when compared to the shod condition. Both devices also resulted in an increase in sEMG signal amplitudes, with large effect sizes of the lateral gastrocnemius, rectus femoris, biceps femoris, and gluteus medius during the unipedal-stance-with-eyes-closed test, compared to the shod condition. Wearing ankle destabilization devices caused greater muscle activation during functional exercises in individuals with chronic ankle instability. Based on the magnitude of the effect, there were consistent increases in fibularis longus sEMG amplitudes during the unipedal eyes-closed balance test, the Star Excursion Balance Test in the anterior and posteromedial directions, and pre-initial contact and post-initial contact during lateral hops and walking.

  13. Epitaxially grown collagen fibrils reveal diversity in contact guidance behavior among cancer cells.

    PubMed

    Wang, Juan; Petefish, Joseph W; Hillier, Andrew C; Schneider, Ian C

    2015-01-01

    Invasion of cancer cells into the surrounding tissue is an important step during cancer progression and is driven by cell migration. Cell migration can be random, but often it is directed by various cues such as aligned fibers composed of extracellular matrix (ECM), a process called contact guidance. During contact guidance, aligned fibers bias migration along the long axis of the fibers. These aligned fibers of ECM are commonly composed of type I collagen, an abundant structural protein around tumors. In this paper, we epitaxially grew several different patterns of organized type I collagen on mica and compared the morphology and contact guidance behavior of two invasive breast cancer cell lines (MDA-MB-231 and MTLn3 cells). Others have shown that these cells randomly migrate in qualitatively different ways. MDA-MB-231 cells exert large traction forces, tightly adhere to the ECM, and migrate with spindle-shaped morphology and thus adopt a mesenchymal mode of migration. MTLn3 cells exert small traction forces, loosely adhere to the ECM, and migrate with a more rounded morphology and thus adopt an amoeboid mode of migration. As the degree of alignment of type I collagen fibrils increases, cells become more elongated and engage in more directed contact guidance. MDA-MB-231 cells perceive the directional signal of highly aligned type I collagen fibrils with high fidelity, elongating to large extents and migrating directionally. Interestingly, behavior in MTLn3 cells differs. While highly aligned type I collagen fibril patterns facilitate spreading and random migration of MTLn3 cells, they do not support elongation or directed migration. Thus, different contact guidance cues bias cell migration differently and the fidelity of contact guidance is cell type dependent, suggesting that ECM alignment is a permissive cue for contact guidance, but requires a cell to have certain properties to interpret that cue.

  14. Super-Hydrophobic Green Corrosion Inhibitor On Carbon Steel

    NASA Astrophysics Data System (ADS)

    Hassan, H.; Ismail, A.; Ahmad, S.; Soon, C. F.

    2017-06-01

    There are many examples of organic coatings used for corrosion protection. In particular, hydrophobic and super-hydrophobic coatings are shown to give good protection because of their enhanced ability to slow down transport of water and ions through the coating. The purpose of this research is to develop water repellent coating to avoid direct contact between metal and environment corrosive and mitigate corrosion attack at pipeline system. This water repellent characteristic on super-hydrophobic coating was coated by electrodeposition method. Wettability of carbon steel with super-hydrophobic coating (cerium chloride and myristic acid) and oxidized surface was investigated through contact angle and inhibitor performance test. The inhibitor performance was studied in 25% tannin acid corrosion test at 30°C and 3.5% sodium chloride (NaCl). The water contact angle test was determined by placing a 4-μL water droplet of distilled water. It shows that the wettability of contact angle super-hydrophobic with an angle of 151.60° at zero minute can be classified as super-hydrophobic characteristic. By added tannin acid as inhibitor the corrosion protection on carbon steel becomes more consistent. This reveals that the ability of the coating to withstand with the corrosion attack in the seawater at different period of immersions. The results elucidate that the weight loss increased as the time of exposure increased. However, the corrosion rates for uncoated carbon steel is high compared to coated carbon steel. As a conclusion, from both samples it can be seen that the coated carbon steel has less corrosion rated compared to uncoated carbon steel and addition of inhibitor to the seawater provides more protection to resist corrosion attack on carbon steel.

  15. Demonstration of the Feasibility of High Temperature Bearing Lubrication From Carbonaceous Gases

    NASA Technical Reports Server (NTRS)

    Blanchet, Thierry A.; Sawyer, W. Gregory

    1996-01-01

    Research has been conducted on silicon nitride pin-on-disk sliding contacts at temperatures of up to 520 C, and four-ball rolling contacts with silicon nitride balls and 52100 steel or silicon nitride races at 590 C. These tests were conducted in a variety of gaseous environments in order to determine the effects of simulated engine exhaust gas on the carbonaceous gas decomposition lubrication scheme. In rolling tests with steel races and exhaust gas the wear track depth was roughly half that of tests run in nitrogen gas alone. The deposition of lubricous microcrystalline graphitic carbon on the rolling surfaces, generated from the carbon monoxide within the exhaust gas mixture, was verified by microfocused Raman spectroscopy. Ten-fold reductions in rolling wear could be achieved by the exhaust gas atmosphere in cases where water vapor was removed or not present. The exhaust gas mixture alone was not found to provide any lubricating effect on silicon nitride sliding contacts, where the rate of wear greatly exceeds the rate of carbon deposition. Directed admixture of acetylene (as low as 5% of the exhaust gas flow rates), has provided reductions in both wear volume and coefficient of friction by factors of 60X and 20X respectively for sliding contacts during the initial 80 m of sliding distance. Exhaust gas atmosphere with the acetylene admixture provided 65OX reductions in steady state wear rate compared to that measured for sliding contacts in dry N2. Such acetylene admixture also augments the ability of the exhaust gas atmosphere to lubricate high-temperature rolling contacts, with up to 25-fold reductions in wear track depth compared to those measured in the presence of N2 alone. In addition to providing some lubricating benefit itself, an important potential role of the exhaust gas from rich mixtures would be to shield bearings from 02. Such shielding enables surface deposition of lubricous pyrolytic carbon from the acetylene admixture, instead of combustion, rendering feasible the continuously replenished solid lubrication of high-temperature bearing surfaces.

  16. Compatibility between Co-Metallized PbTe Thermoelectric Legs and an Ag–Cu–In Brazing Alloy

    PubMed Central

    Ben-Ayoun, Dana; Sadia, Yatir; Gelbstein, Yaniv

    2018-01-01

    In thermoelectric (TE) generators, maximizing the efficiency of conversion of direct heat to electricity requires the reduction of any thermal and electrical contact resistances between the TE legs and the metallic contacts. This requirement is especially challenging in the development of intermediate to high-temperature TE generators. PbTe-based TE materials are known to be highly efficient up to temperatures of around 500 °C; however, only a few practical TE generators based on these materials are currently commercially available. One reason for that is the insufficient bonding techniques between the TE legs and the hot-side metallic contacts. The current research is focused on the interaction between cobalt-metallized n-type 9.104 × 10−3 mol % PbI2-doped PbTe TE legs and the Ag0.32Cu0.43In0.25 brazing alloy, which is free of volatile species. Clear and fine interfaces without any noticeable formation of adverse brittle intermetallic compounds were observed following prolonged thermal treatment testing. Moreover, a reasonable electrical contact resistance of ~2.25 mΩmm2 was observed upon brazing at 600 °C, highlighting the potential of such contacts while developing practical PbTe-based TE generators. PMID:29320430

  17. Evaluation of implant osseointegration with different regeneration techniques in the treatment of bone defects around implants: an experimental study in a rabbit model.

    PubMed

    Guerra, Isabel; Morais Branco, Fernando; Vasconcelos, Mário; Afonso, Américo; Figueiral, Helena; Zita, Raquel

    2011-03-01

    The aim of this study was to evaluate the osseointegration of implants placed in areas with artificially created bone defects, using three bone regeneration techniques. The experimental model was the rabbit femur (16), where bone defects were created and implants were placed. The peri-implant bone defects were filled with a deproteinized bovine bone mineral, NuOss™ (N), NuOss™ combined with plasma rich in growth factors (PRGF) (N+PRGF), NuOss™ covered by an RCM(6) membrane (N+M), or remained unfilled (control group [C]). After 4 and 8 weeks, the animals were euthanized and bone tissue blocks with the implants and the surrounding bone tissue were removed and processed according to a histological protocol for hard tissues on non-decalcified ground sections. The samples were studied by light and electron scanning microscopy, histometric analysis was performed to assess the percentage of bone in direct contact with the implant surface and a statistical analysis of the results was performed. In the samples analyzed 4 weeks after implantation, the percentage of bone tissue in direct contact with the implant surface for the four groups were 57.66±24.39% (N), 58.62±20.37% (N+PRGF), 70.82±20.34 % (N+M) and 33.07±5.49% (C). In the samples with 8 weeks of implantation time, the percentage of bone in direct contact was 63.35±27.69% (N), 58.42±24.77% (N+PRGF), 78.02±15.13% (N+M) and 40.28±27.32% (C). In terms of the percentage of bone contact, groups N and N+M presented statistically significant differences from group C in the 4-week trial test (P<0.05; ANOVA). For the 8-week results, only group N+M showed statistically significant differences when compared with group C (P<0.05; ANOVA). In conclusion, the NuOss™ granules/RCM(6) membrane combination presented a percentage of bone contact with the implant surface statistically greater than in the other groups. © 2010 John Wiley & Sons A/S.

  18. Review of test methods used to determine the corrosion rate of metals in contact with treated wood

    Treesearch

    Samuel L. Zelinka; Douglas R. Rammer

    2005-01-01

    The purpose of this literature review is to give an overview of test methods previously used to evaluate the corrosion of metals in contact with wood. This article reviews the test methods used to evaluate the corrosion of metals in contact with wood by breaking the experiments into three groups: exposure tests, accelerated exposure tests, and electrochemical tests....

  19. Robust and general method for determining surface fluid flow boundary conditions in articular cartilage contact mechanics modeling.

    PubMed

    Pawaskar, Sainath Shrikant; Fisher, John; Jin, Zhongmin

    2010-03-01

    Contact detection in cartilage contact mechanics is an important feature of any analytical or computational modeling investigation when the biphasic nature of cartilage and the corresponding tribology are taken into account. The fluid flow boundary conditions will change based on whether the surface is in contact or not, which will affect the interstitial fluid pressurization. This in turn will increase or decrease the load sustained by the fluid phase, with a direct effect on friction, wear, and lubrication. In laboratory experiments or clinical hemiarthroplasty, when a rigid indenter or metallic prosthesis is used to apply load to the cartilage, there will not be any fluid flow normal to the surface in the contact region due to the impermeable nature of the indenter/prosthesis. In the natural joint, on the other hand, where two cartilage surfaces interact, flow will depend on the pressure difference across the interface. Furthermore, in both these cases, the fluid would flow freely in non-contacting regions. However, it should be pointed out that the contact area is generally unknown in advance in both cases and can only be determined as part of the solution. In the present finite element study, a general and robust algorithm was proposed to decide nodes in contact on the cartilage surface and, accordingly, impose the fluid flow boundary conditions. The algorithm was first tested for a rigid indenter against cartilage model. The algorithm worked well for two-dimensional four-noded and eight-noded axisymmetric element models as well as three-dimensional models. It was then extended to include two cartilages in contact. The results were in excellent agreement with the previous studies reported in the literature.

  20. Light transfer through windows with external condensation

    NASA Astrophysics Data System (ADS)

    Zhu, Keyong; Li, Shaoling; Pilon, Laurent

    2018-03-01

    This study investigates systematically light transfer through windows supporting cap-shaped droplets on their external face. The presence of such droplets may have negative effects on the conversion efficiency of solar cells, distorts image quality of lenses, or hinders visibility through windows and windshields. Here, the directional-hemispherical transmittance was predicted by the Monte Carlo ray-tracing method. The droplets were monodisperse or polydisperse randomly distributed on the outside face of optically smooth windows. For nonabsorbing droplets, the diameter and size distribution did not have a significant effect on the window directional-hemispherical transmittance. The latter was nearly independent of contact angle for incident angle θi ≤ 30°. However, the directional-hemispherical transmittance decreased monotonously with increasing incident angle and droplet contact angle for contact angle θc ≤ 70° to reach a minimum at a contact angle θc,min beyond which it increased with increasing contact angle before reaching a plateau at large contact angles. This was attributed to total internal reflection at the back window/air and droplet/air interfaces. For absorbing droplets, the normal-hemispherical transmittance decreased significantly with increasing droplet contact angle, mean diameter, polydispersity, and projected surface area coverage due to strong absorption within the droplets. Moreover, the normal-hemispherical transmittance decreased with increasing contact angle for θc< 90° and remained constant and independent of the droplets' absorption index, mean diameter, and contact angle for θc ≥ 90°. Finally, Analytical expressions for the upper and lower bounds of the normal-hemispherical transmittance as a function of droplet contact angle, optical properties, and projected surface area coverage were derived.

  1. Contact integrity testing of stress-tested silicon terrestrial solar cells

    NASA Technical Reports Server (NTRS)

    Prince, J. L.; Lathrop, J. W.; Witter, G. W.

    1980-01-01

    A test procedure was developed and applied to terrestrial silicon solar cells in order to determine the effect of accelerated environmental and time-temperature aging on metal contact integrity. Quantities of cells of four different manufacturers were given the contact integrity test after being subjected to accelerated stress tests that included forward bias-temperature, thermal cycle and thermal shock, power cycle, and bias-temperature humidity tests at two temperature-humidity levels. Significant effects due to certain stress tests were found for some cell types. It is concluded that cells fabricated using plated nickel/solder metallization showed significantly more serious contact integrity degradation than silver-metallized cells.

  2. Formation of retinal direction-selective circuitry initiated by starburst amacrine cell homotypic contact

    PubMed Central

    Ray, Thomas A; Roy, Suva; Kozlowski, Christopher; Wang, Jingjing; Cafaro, Jon; Hulbert, Samuel W; Wright, Christopher V; Field, Greg D

    2018-01-01

    A common strategy by which developing neurons locate their synaptic partners is through projections to circuit-specific neuropil sublayers. Once established, sublayers serve as a substrate for selective synapse formation, but how sublayers arise during neurodevelopment remains unknown. Here, we identify the earliest events that initiate formation of the direction-selective circuit in the inner plexiform layer of mouse retina. We demonstrate that radially migrating newborn starburst amacrine cells establish homotypic contacts on arrival at the inner retina. These contacts, mediated by the cell-surface protein MEGF10, trigger neuropil innervation resulting in generation of two sublayers comprising starburst-cell dendrites. This dendritic scaffold then recruits projections from circuit partners. Abolishing MEGF10-mediated contacts profoundly delays and ultimately disrupts sublayer formation, leading to broader direction tuning and weaker direction-selectivity in retinal ganglion cells. Our findings reveal a mechanism by which differentiating neurons transition from migratory to mature morphology, and highlight this mechanism’s importance in forming circuit-specific sublayers. PMID:29611808

  3. Changes in contact angle providing evidence for surface alteration in multi-component solid foods

    NASA Astrophysics Data System (ADS)

    Reinke, Svenja K.; Hauf, Katharina; Vieira, Josélio; Heinrich, Stefan; Palzer, Stefan

    2015-11-01

    Chocolate blooming, one of the major problems in the confectionery industry, is the formation of visible white spots or a greyish haze on the surface of chocolate products due to large sugar or fat crystals on the surface. This leads to aesthetic changes and deterioration of taste and thus large sales losses for the confectionery industry due to consumer complaints. Chocolate blooming is often related to migration of lipids or sugar molecules to the chocolate surface, where they recrystallize with an associated polymorphic change of crystal structure on the surface. The wetting behaviour from contact angle measurements gives further insight into surface properties and is needed to determine surface energies and to evaluate possible migration mechanisms and preferred pathways. Therefore, an equilibrium contact angle is needed which is not directly accessible and is influenced by surface texture and interaction between solid and test liquid. In this study, the surface of cocoa butter and conventional chocolates was characterized by measuring the contact angle with the sessile drop protocol. The influence of roughness, test liquid and pre-crystallization of the samples as well as the storage temperature were investigated. In case of no pre-crystallization, a change in surface properties due to storage at 20 °C was detected, whereas samples stored at 30 °C showed the same wetting behaviour as fresh samples. This is associated with polymorphic transformation from thermodynamically less stable crystals to more stable configurations.

  4. Association between pet ownership and the sensitization to pet allergens in adults with various allergic diseases.

    PubMed

    Park, Yong-Bum; Mo, Eun-Kyung; Lee, Jae-Young; Kim, Joo-Hee; Kim, Cheol-Hong; Hyun, In-Gyu; Choi, Jeong-Hee

    2013-09-01

    As pet ownership increases, sensitization to animal allergens due to domestic exposure is a concern. Sensitization to animal allergens may occur from indirect exposure, as well as direct ownership of animals. However, there have been conflicting results regarding the association between pet ownership and sensitization to animal allergens in adults. In total, 401 patients with various allergic diseases were enrolled in this study. We performed skin prick tests with 55 common inhalant and food allergens, including dog, cat, and rabbit allergens. A mean wheal diameter of 3 mm or greater was considered a positive reaction. The exposure modality to each animal allergen was investigated using a questionnaire and included present ownership, past ownership, occupational exposure, occasional exposure, contact with pet owner, and no contact. Present ownership, past ownership, occupational, and occasional exposure were regarded as direct exposure. The sensitization rate for animal allergens was 20.4% for dog, 15.0% for cat, and 9.0% for rabbit. Direct exposure to dogs (72.0%) was significantly higher than that of other animals (18.4% for cats and 16.7% for rabbits), whereas 'no contact' with cats (78.3%) and rabbits (83.3%) was significantly higher than with dogs (26.8%; P<0.0001). Independent risk factors for sensitization to animal allergens were sensitization to Dermatophagoides pteronyssinus (OR=2.4, P=0.052), Dermatophagoides farinae (OR=5.1, P<0.001), cat (OR=4.4, P<0.0001), and direct exposure to dogs (OR=1.5, P=0.029) for dog, and sensitization to dog (OR=4.4, P<0.0001) and rabbit (OR=2.6, P=0.036) for cats. Finally, for rabbits, the independent risk factor was sensitization to Alternaria (OR=6.0, P<0.002). These results suggest that direct exposure to dogs contributes to the sensitization to dog allergens in patients with allergic diseases, whereas indirect exposure to cats and rabbits may induce sensitization to each animal's allergen.

  5. The COBAIN (COntact Binary Atmospheres with INterpolation) Code for Radiative Transfer

    NASA Astrophysics Data System (ADS)

    Kochoska, Angela; Prša, Andrej; Horvat, Martin

    2018-01-01

    Standard binary star modeling codes make use of pre-existing solutions of the radiative transfer equation in stellar atmospheres. The various model atmospheres available today are consistently computed for single stars, under different assumptions - plane-parallel or spherical atmosphere approximation, local thermodynamical equilibrium (LTE) or non-LTE (NLTE), etc. However, they are nonetheless being applied to contact binary atmospheres by populating the surface corresponding to each component separately and neglecting any mixing that would typically occur at the contact boundary. In addition, single stellar atmosphere models do not take into account irradiance from a companion star, which can pose a serious problem when modeling close binaries. 1D atmosphere models are also solved under the assumption of an atmosphere in hydrodynamical equilibrium, which is not necessarily the case for contact atmospheres, as the potentially different densities and temperatures can give rise to flows that play a key role in the heat and radiation transfer.To resolve the issue of erroneous modeling of contact binary atmospheres using single star atmosphere tables, we have developed a generalized radiative transfer code for computation of the normal emergent intensity of a stellar surface, given its geometry and internal structure. The code uses a regular mesh of equipotential surfaces in a discrete set of spherical coordinates, which are then used to interpolate the values of the structural quantites (density, temperature, opacity) in any given point inside the mesh. The radiaitive transfer equation is numerically integrated in a set of directions spanning the unit sphere around each point and iterated until the intensity values for all directions and all mesh points converge within a given tolerance. We have found that this approach, albeit computationally expensive, is the only one that can reproduce the intensity distribution of the non-symmetric contact binary atmosphere and can be used with any existing or new model of the structure of contact binaries. We present results on several test objects and future prospects of the implementation in state-of-the-art binary star modeling software.

  6. Intraoral versus extraoral measurement of the height of the interproximal contact area in maxillary anterior teeth.

    PubMed

    Sghaireen, Mohd G; Albhiran, Heyam Mobark; Alzoubi, Ibrahim A; Lynch, Edward; Al-Omiri, Mahmoud K

    2015-01-01

    This study aimed to clinically quantify the apicoincisal height of the upper interproximal areas directly in patients' mouths compared to measurements on stone models. One hundred and fifty participants (75 females and 75 males, age range 20-45 years) were recruited for this study. A digital caliper was used to measure the anterior maxillary interproximal contact areas directly in patients' mouths and on stone models. The digital caliper accuracy was up to 0.01. The Statistical Package for Social Sciences software (SPSS, version 19.0, Chicago, Ill., USA) was used for statistical analysis. Statistical significance was based on probability values <0.05. The intraoral measurement of proximal contacts as well as the measurement on stone models showed that the dimensions of interproximal contacts on both sides of each tooth were significantly different (p < 0.001) and that the dimension of the mesial contact point was larger than that of the distal contact point of each tooth. The largest contact point was the one between the central incisors (direct intraoral measurement = 2.9-6.49 mm; model measurement = 3.31-6.91 mm). On the other hand, the contact point between the canine and first premolar was the smallest on both sides of the arch (0.63-2.52 mm intraorally, 0.98-2.88 mm on models). The intraoral measurement of contact points was more accurate than model measurements, and the differences were statistically significant (p < 0.001). The clinical evaluation of contact point dimensions using a digital caliper was more precise than measuring contact points on stone models; hence, it is a viable, quick and adequate method to be used routinely. © 2015 S. Karger AG, Basel.

  7. Knee medial and lateral contact forces in a musculoskeletal model with subject-specific contact point trajectories.

    PubMed

    Zeighami, A; Aissaoui, R; Dumas, R

    2018-03-01

    Contact point (CP) trajectory is a crucial parameter in estimating medial/lateral tibio-femoral contact forces from the musculoskeletal (MSK) models. The objective of the present study was to develop a method to incorporate the subject-specific CP trajectories into the MSK model. Ten healthy subjects performed 45 s treadmill gait trials. The subject-specific CP trajectories were constructed on the tibia and femur as a function of extension-flexion using low-dose bi-plane X-ray images during a quasi-static squat. At each extension-flexion position, the tibia and femur CPs were superimposed in the three directions on the medial side, and in the anterior-posterior and proximal-distal directions on the lateral side to form the five kinematic constraints of the knee joint. The Lagrange multipliers associated to these constraints directly yielded the medial/lateral contact forces. The results from the personalized CP trajectory model were compared against the linear CP trajectory and sphere-on-plane CP trajectory models which were adapted from the commonly used MSK models. Changing the CP trajectory had a remarkable impact on the knee kinematics and changed the medial and lateral contact forces by 1.03 BW and 0.65 BW respectively, in certain subjects. The direction and magnitude of the medial/lateral contact force were highly variable among the subjects and the medial-lateral shift of the CPs alone could not determine the increase/decrease pattern of the contact forces. The suggested kinematic constraints are adaptable to the CP trajectories derived from a variety of joint models and those experimentally measured from the 3D imaging techniques. Copyright © 2018 Elsevier Ltd. All rights reserved.

  8. High-Throughput Toxicity Testing: New Strategies for ...

    EPA Pesticide Factsheets

    In recent years, the food industry has made progress in improving safety testing methods focused on microbial contaminants in order to promote food safety. However, food industry toxicologists must also assess the safety of food-relevant chemicals including pesticides, direct additives, and food contact substances. With the rapidly growing use of new food additives, as well as innovation in food contact substance development, an interest in exploring the use of high-throughput chemical safety testing approaches has emerged. Currently, the field of toxicology is undergoing a paradigm shift in how chemical hazards can be evaluated. Since there are tens of thousands of chemicals in use, many of which have little to no hazard information and there are limited resources (namely time and money) for testing these chemicals, it is necessary to prioritize which chemicals require further safety testing to better protect human health. Advances in biochemistry and computational toxicology have paved the way for animal-free (in vitro) high-throughput screening which can characterize chemical interactions with highly specific biological processes. Screening approaches are not novel; in fact, quantitative high-throughput screening (qHTS) methods that incorporate dose-response evaluation have been widely used in the pharmaceutical industry. For toxicological evaluation and prioritization, it is the throughput as well as the cost- and time-efficient nature of qHTS that makes it

  9. Length scale selects directionality of droplets on vibrating pillar ratchet

    DOE PAGES

    Agapov, Rebecca L.; Boreyko, Jonathan B.; Briggs, Dayrl P.; ...

    2014-09-22

    Directional control of droplet motion at room temperature is of interest for applications such as microfluidic devices, self-cleaning coatings, and directional adhesives. Here, arrays of tilted pillars ranging in height from the nanoscale to the microscale are used as structural ratchets to directionally transport water at room temperature. Water droplets deposited on vibrating chips with a nanostructured ratchet move preferentially in the direction of the feature tilt while the opposite directionality is observed in the case of microstructured ratchets. This remarkable switch in directionality is consistent with changes in the contact angle hysteresis. To glean further insights into the lengthmore » scale dependent asymmetric contact angle hysteresis, the contact lines formed by a nonvolatile room temperature ionic liquid placed onto the tilted pillar arrays were visualized and analyzed in situ in a scanning electron microscope. As a result, the ability to tune droplet directionality by merely changing the length scale of surface features all etched at the same tilt angle would be a versatile tool for manipulating multiphase flows and for selecting droplet directionality in other lap-on-chip applications.« less

  10. Stokes flow inside an evaporating liquid line for any contact angle

    NASA Astrophysics Data System (ADS)

    Petsi, A. J.; Burganos, V. N.

    2008-09-01

    Evaporation of droplets or liquid films lying on a substrate induces internal viscous flow, which affects the transport of suspended particles and, thus, the final deposit profile in numerous applications. In this work, the problem of Stokes flow inside a two-dimensional droplet, representing the cross section of an evaporating liquid line lying on a flat surface, is considered. The stream function formulation is adopted, leading to the biharmonic equation in bipolar coordinates. A solution in closed form is obtained for any contact angle in (0,π) and is, thus, valid for both hydrophilic and hydrophobic substrates. The solution can be used with any type of evaporation mechanism, including diffusion, convection, or kinetically controlled modes. Both pinned and depinned contact lines are considered. For the boundary conditions to be compatible at the contact lines, the Navier slip boundary condition is applied on the substrate. Numerical results are presented for kinetically and diffusion controlled evaporation. For pinned contact lines, the flow inside the evaporating liquid line is directed towards the edges, thus, promoting the coffee stain phenomenon. In the case of depinned contact lines and contact angle less than π/2 , the flow is directed towards the center of the droplet, whereas, for strongly hydrophobic substrates it is directed outwards.

  11. Force Transmission Modes of Non-Cohesive and Cohesive Materials at the Critical State.

    PubMed

    Wang, Ji-Peng

    2017-08-31

    This paper investigates the force transmission modes, mainly described by probability density distributions, in non-cohesive dry and cohesive wet granular materials by discrete element modeling. The critical state force transmission patterns are focused on with the contact model effect being analyzed. By shearing relatively dense and loose dry specimens to the critical state in the conventional triaxial loading path, it is observed that there is a unique critical state force transmission mode. There is a universe critical state force distribution pattern for both the normal contact forces and tangential contact forces. Furthermore, it is found that using either the linear Hooke or the non-linear Hertz model does not affect the universe force transmission mode, and it is only related to the grain size distribution. Wet granular materials are also simulated by incorporating a water bridge model. Dense and loose wet granular materials are tested, and the critical state behavior for the wet material is also observed. The critical state strength and void ratio of wet granular materials are higher than those of a non-cohesive material. The critical state inter-particle distribution is altered from that of a non-cohesive material with higher probability in relatively weak forces. Grains in non-cohesive materials are under compressive stresses, and their principal directions are mainly in the axial loading direction. However, for cohesive wet granular materials, some particles are in tension, and the tensile stresses are in the horizontal direction on which the confinement is applied. The additional confinement by the tensile stress explains the macro strength and dilatancy increase in wet samples.

  12. Cattle-derived microbial input to source water catchments: An experimental assessment of stream crossing modification.

    PubMed

    Smolders, Andrew; Rolls, Robert J; Ryder, Darren; Watkinson, Andrew; Mackenzie, Mark

    2015-06-01

    The provision of safe drinking water is a global issue, and animal production is recognized as a significant potential origin of human infectious pathogenic microorganisms within source water catchments. On-farm management can be used to mitigate livestock-derived microbial pollution in source water catchments to reduce the risk of contamination to potable water supplies. We applied a modified Before-After Control Impact (BACI) design to test if restricting the access of livestock to direct contact with streams prevented longitudinal increases in the concentrations of faecal indicator bacteria and suspended solids. Significant longitudinal increases in pollutant concentrations were detected between upstream and downstream reaches of the control crossing, whereas such increases were not detected at the treatment crossing. Therefore, while the crossing upgrade was effective in preventing cattle-derived point source pollution by between 112 and 158%, diffuse source pollution to water supplies from livestock is not ameliorated by this intervention alone. Our findings indicate that stream crossings that prevent direct contact between livestock and waterways provide a simple method for reducing pollutant loads in source water catchments, which ultimately minimises the likelihood of pathogenic microorganisms passing through source water catchments and the drinking water supply system. The efficacy of the catchment as a primary barrier to pathogenic risks to drinking water supplies would be improved with the integration of management interventions that minimise direct contact between livestock and waterways, combined with the mitigation of diffuse sources of livestock-derived faecal matter from farmland runoff to the aquatic environment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  13. Force Transmission Modes of Non-Cohesive and Cohesive Materials at the Critical State

    PubMed Central

    2017-01-01

    This paper investigates the force transmission modes, mainly described by probability density distributions, in non-cohesive dry and cohesive wet granular materials by discrete element modeling. The critical state force transmission patterns are focused on with the contact model effect being analyzed. By shearing relatively dense and loose dry specimens to the critical state in the conventional triaxial loading path, it is observed that there is a unique critical state force transmission mode. There is a universe critical state force distribution pattern for both the normal contact forces and tangential contact forces. Furthermore, it is found that using either the linear Hooke or the non-linear Hertz model does not affect the universe force transmission mode, and it is only related to the grain size distribution. Wet granular materials are also simulated by incorporating a water bridge model. Dense and loose wet granular materials are tested, and the critical state behavior for the wet material is also observed. The critical state strength and void ratio of wet granular materials are higher than those of a non-cohesive material. The critical state inter-particle distribution is altered from that of a non-cohesive material with higher probability in relatively weak forces. Grains in non-cohesive materials are under compressive stresses, and their principal directions are mainly in the axial loading direction. However, for cohesive wet granular materials, some particles are in tension, and the tensile stresses are in the horizontal direction on which the confinement is applied. The additional confinement by the tensile stress explains the macro strength and dilatancy increase in wet samples. PMID:28858238

  14. Thermochemical generation of hydrogen

    NASA Technical Reports Server (NTRS)

    Lawson, D. D.; Petersen, G. R. (Inventor)

    1982-01-01

    The direct fluid contact heat exchange with H2SO4 at about 330 C prior to high temperature decomposition at about 830 C in the oxygen release step of several thermochemical cycles for splitting water into hydrogen and oxygen provides higher heat transfer rates, savings in energy and permits use of cast vessels rather than expensive forged alloy indirect heat exchangers. Among several candidate perfluorocarbon liquids tested, only perfluoropropylene oxide polymers having a degree of polymerization from about 10 to 60 were chemically stable, had low miscibility and vapor pressure when tested with sulfuric acid at temperatures from 300 C to 400 C.

  15. 21 CFR 886.5925 - Soft (hydrophilic) contact lens.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Soft (hydrophilic) contact lens. 886.5925 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5925 Soft (hydrophilic) contact lens. (a) Identification. A soft (hydrophilic) contact lens is a device intended to be worn directly...

  16. 21 CFR 886.5925 - Soft (hydrophilic) contact lens.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Soft (hydrophilic) contact lens. 886.5925 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5925 Soft (hydrophilic) contact lens. (a) Identification. A soft (hydrophilic) contact lens is a device intended to be worn directly...

  17. Refrigerant directly cooled capacitors

    DOEpatents

    Hsu, John S [Oak Ridge, TN; Seiber, Larry E [Oak Ridge, TN; Marlino, Laura D [Oak Ridge, TN; Ayers, Curtis W [Kingston, TN

    2007-09-11

    The invention is a direct contact refrigerant cooling system using a refrigerant floating loop having a refrigerant and refrigeration devices. The cooling system has at least one hermetic container disposed in the refrigerant floating loop. The hermetic container has at least one electronic component selected from the group consisting of capacitors, power electronic switches and gating signal module. The refrigerant is in direct contact with the electronic component.

  18. Allergic Contact Dermatitis to Ophthalmic Medications: Relevant Allergens and Alternative Testing Methods.

    PubMed

    Grey, Katherine R; Warshaw, Erin M

    Allergic contact dermatitis is an important cause of periorbital dermatitis. Topical ophthalmic agents are relevant sensitizers. Contact dermatitis to ophthalmic medications can be challenging to diagnose and manage given the numerous possible offending agents, including both active and inactive ingredients. Furthermore, a substantial body of literature reports false-negative patch test results to ophthalmic agents. Subsequently, numerous alternative testing methods have been described. This review outlines the periorbital manifestations, causative agents, and alternative testing methods of allergic contact dermatitis to ophthalmic medications.

  19. Health effects of oil mists: a brief review.

    PubMed

    Mackerer, C R

    1989-05-01

    Metal cutting/grinding fluids are of three basic types: straight oil (insoluble), oil-in-water emulsions (soluble) and synthetic/semisynthetic. All contain a variety of additives to improve performance. Human exposure occurs primarily by direct skin contact with the liquid or by skin and respiratory contact after fluid misting. Dermatitis caused by primary or direct skin irritation is the most prevalent health effect of exposure to cutting fluids. Occasionally allergic dermatitis is seen which is related to the development of sensitization to one or more of the additive components. Recent studies indicate that long-term exposure to cutting fluids does not result in increased incidences of lung cancer, urinary bladder cancer, gastrointestinal cancer, or death from non-malignant respiratory diseases. Long-term exposure to certain cutting fluids, however, is believed to have resulted in certain types of skin cancer, especially scrotal cancer. It is likely that these carcinogenic responses were caused by contact with polycyclic aromatic compounds (PCA) of 3-7 rings. Modern base oils which are severely refined have very low levels of PCA, are not carcinogenic in animal bioassays, and are unlikely to be carcinogenic in man. This is not necessarily true for re-refined oils which may contain significant levels of PCA and polychlorinated biphenyls derived from comingling used cutting oils with used engine oils and transformer oils. Cutting oils, themselves, generally do not accumulate significant levels of carcinogenic PCA during use. Additives, in theory, can cause a variety of health effects either directly or through the generation of reaction products such as nitrosamines. In actual use, adverse health effects appear to be limited to occasional instances of allergic contact dermatitis. Nitrosamines are extremely carcinogenic in test animals; although no human cancer cases directly attributable to nitrosamine contamination have been observed, nitrosating agents and amines should not be combined in cutting fluid formulations. It is difficult to anticipate or predict the potential toxicity of a particular cutting fluid formulation because of the presence of variable amounts of proprietary additives which, themselves, are often complex reaction mixtures. Thus, each additive and final formulation must be evaluated on a case by case basis to appropriately assess potential health hazards.

  20. Phylogeography of speciation: allopatric divergence and secondary contact between outcrossing and selfing Clarkia.

    PubMed

    Pettengill, James B; Moeller, David A

    2012-09-01

    The origins of hybrid zones between parapatric taxa have been of particular interest for understanding the evolution of reproductive isolation and the geographic context of species divergence. One challenge has been to distinguish between allopatric divergence (followed by secondary contact) versus primary intergradation (parapatric speciation) as alternative divergence histories. Here, we use complementary phylogeographic and population genetic analyses to investigate the recent divergence of two subspecies of Clarkia xantiana and the formation of a hybrid zone within the narrow region of sympatry. We tested alternative phylogeographic models of divergence using approximate Bayesian computation (ABC) and found strong support for a secondary contact model and little support for a model allowing for gene flow throughout the divergence process (i.e. primary intergradation). Two independent methods for inferring the ancestral geography of each subspecies, one based on probabilistic character state reconstructions and the other on palaeo-distribution modelling, also support a model of divergence in allopatry and range expansion leading to secondary contact. The membership of individuals to genetic clusters suggests geographic substructure within each taxon where allopatric and sympatric samples are primarily found in separate clusters. We also observed coincidence and concordance of genetic clines across three types of molecular markers, which suggests that there is a strong barrier to gene flow. Taken together, our results provide evidence for allopatric divergence followed by range expansion leading to secondary contact. The location of refugial populations and the directionality of range expansion are consistent with expectations based on climate change since the last glacial maximum. Our approach also illustrates the utility of combining phylogeographic hypothesis testing with species distribution modelling and fine-scale population genetic analyses for inferring the geography of the divergence process. © 2012 Blackwell Publishing Ltd.

  1. 37 CFR 10.33 - Direct contact with prospective clients.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Direct contact with prospective clients. 10.33 Section 10.33 Patents, Trademarks, and Copyrights UNITED STATES PATENT AND... clients. A practitioner may not solicit professional employment from a prospective client with whom the...

  2. A Survey Examining Photopatch Test and Phototest Methodologies of Contact Dermatologists in the United States: Platform for Developing A Consensus.

    PubMed

    Asemota, Eseosa; Crawford, Glen; Kovarik, Carrie; Brod, Bruce A

    There is currently no standardized protocol for photopatch testing and phototesting in the United States. Certain testing paramaters (such as chemicals tested, time between test application and irradiation, and time of final interpretation) vary from provider to provider. These variations may impact comparability and consistency of test results. The goal of our survey-based study was to outline the photopatch test and phototest protocols used by US contact dermatologists. The information obtained will aid in the development of a national consensus on testing methodologies. Based on a literature search conducted on differences in testing methodologies, we constructed a questionnaire. The survey was distributed at the American Contact Dermatitis Society annual meeting and via the American Contact Dermatitis Society Web site. Standard descriptive analysis was performed on data obtained. Of the 800 dermatologists contacted, 117 agreed to participate in the survey. Among these respondents, 64 (54.8%) conduct photopatch testing. Results of the survey are presented, and they confirm that a variety of techniques and testing materials are used. It would be beneficial to enlist a panel of expert contact dermatologists to create by formal consensus, using these research findings, a standard photopatch test protocol for use in this country.

  3. Diagnosing Allergic Contact Dermatitis Through Elimination, Perception, Detection and Deduction.

    PubMed

    Pongpairoj, Korbkarn; Puangpet, Pailin; Thaiwat, Supitchaya; McFadden, John P

    2017-10-01

    Several authors have commented upon the skills of detection required in making a diagnosis of allergic contact dermatitis. Here, we emphasise the search for clues in a systematic manner. We describe four stages as part of a systematic method for diagnosing allergic contact dermatitis. Firstly, elimination (or inclusion) of non-allergic diagnoses. Secondly, perception: the pre-patch test diagnosis and the 'three scenarios' principle. Thirdly, detection: optimising the sensitivity of the patch test process. Fourthly, deduction: diagnosing allergic contact dermatitis by associating the dermatitis with the allergen exposure. We further compare and contrast the pre-patch test history and examination with the markedly different one ('microhistory' and 'microexamination') used after patch testing. The importance of knowledge of contact dermatitis literature is emphasised with a review of recent publications. Finally, we also highlight the use of contact allergy profiling as an investigative tool in the diagnosis of allergic contact dermatitis.

  4. Pediatric Baseline Patch Test Series: Initial Findings of the Pediatric Contact Dermatitis Workgroup.

    PubMed

    Yu, JiaDe; Atwater, Amber Reck; Brod, Bruce; Chen, Jennifer K; Chisolm, Sarah S; Cohen, David E; de la Feld, Salma; Gaspari, Anthony A; Martin, Kari Lyn; Montanez-Wiscovich, Marjorie; Sheehan, Michael; Silverberg, Nanette; Lugo-Somolinos, Aida; Thakur, Binod K; Watsky, Kalman; Jacob, Sharon E

    2018-06-21

    Allergic contact dermatitis is a challenging diagnostic problem in children. Although epicutaneous patch testing is the diagnostic standard for confirmation of contact sensitization, it is less used in children by dermatologists treating children, pediatric dermatologists, and pediatricians, when compared with adult practitioners. The aim of the study was to create and evaluate standardization of a pediatric patch test series for children older than 6 years. We surveyed dermatologists and allergists conducting epicutaneous patch testing in children attending the 2017 American Contact Dermatitis Society meeting held in Washington, DC. This was followed by discussion of collected data and consensus review by a pediatric contact dermatitis working group at the conference. A baseline pediatric patch test panel was established through working group consensus.

  5. The effect of temperature, matrix alloying and substrate coatings on wettability and shear strength of Al/Al2O3 couples

    NASA Astrophysics Data System (ADS)

    Sobczak, N.; Ksiazek, M.; Radziwill, W.; Asthana, R.; Mikulowski, B.

    2004-03-01

    A fresh approach has been advanced to examine in the Al/Al2O3 system the effects of temperature, alloying of Al with Ti or Sn, and Ti and Sn coatings on the substrate, on contact angles measured using a sessile-drop test, and on interface strength measured using a modified push-off test that allows shearing of solidified droplets with less than 90 deg contact angle. In the modified test, the solidified sessile-drop samples are bisected perpendicular to the drop/Al2O3 interface at the midplane of the contact circle to obtain samples that permit bond strength measurement by stress application to the flat surface of the bisected couple. The test results show that interface strength is strongly influenced by the wetting properties; low contact angles correspond to high interface strength, which also exhibits a strong temperature dependence. An increase in the wettability test temperature led to an increase in the interface strength in the low-temperature range where contact angles were large and wettability was poor. The room-temperature shear tests conducted on thermally cycled sessile-drop test specimens revealed the effect of chemically formed interfacial oxides; a weakening of the thermally cycled Al/Al2O3 interface was caused under the following conditions: (1) slow contact heating and short contact times in the wettability test, and (2) fast contact heating and longer contact times. The addition of 6 wt pct Ti or 7 wt pct Sn to Al only marginally influenced the contact angle and interfacial shear strength. However, Al2O3 substrates having thin (<1 µm) Ti coatings yielded relatively low contact angles and high bond strength, which appears to be related to the dissolution of the coating in Al and formation of a favorable interface structure.

  6. The mediating effect of self-esteem, depression and anxiety between satisfaction with body appearance and problematic internet use.

    PubMed

    Koronczai, Beatrix; Kökönyei, Gyöngyi; Urbán, Róbert; Kun, Bernadette; Pápay, Orsolya; Nagygyörgy, Katalin; Griffiths, Mark D; Demetrovics, Zsolt

    2013-07-01

    Given that dissatisfaction with bodily appearance can sometimes lead to the avoidance of personal contacts and the increase of internet use, this study examines this relationship. The direct role of dissatisfaction with bodily appearance along with the possible mediation effects of depression, anxiety and self-esteem were tested. A total of 694 participants completed an online questionnaire (58.5% male, mean age 21.5 years), containing measures on problematic internet use, depression and anxiety symptoms, self-esteem and satisfaction with body image. Path analyses were used to test direct and indirect effects. Satisfaction with body appearance had a significant negative direct effect on problematic internet use among both sexes. Though, satisfaction with body appearance had a positive effect on self-esteem and negative on anxiety, neither self-esteem nor anxiety had a direct significant effect on problematic internet use. The effect of dissatisfaction with body appearance was mediated via the self-esteem-depression path toward problematic internet use. Dissatisfaction with physical appearance seems to have a significant role in individuals' immersing themselves in internet use.

  7. Parameter identification of hyperelastic material properties of the heel pad based on an analytical contact mechanics model of a spherical indentation.

    PubMed

    Suzuki, Ryo; Ito, Kohta; Lee, Taeyong; Ogihara, Naomichi

    2017-01-01

    Accurate identification of the material properties of the plantar soft tissue is important for computer-aided analysis of foot pathologies and design of therapeutic footwear interventions based on subject-specific models of the foot. However, parameter identification of the hyperelastic material properties of plantar soft tissues usually requires an inverse finite element analysis due to the lack of a practical contact model of the indentation test. In the present study, we derive an analytical contact model of a spherical indentation test in order to directly estimate the material properties of the plantar soft tissue. Force-displacement curves of the heel pads are obtained through an indentation experiment. The experimental data are fit to the analytical stress-strain solution of the spherical indentation in order to obtain the parameters. A spherical indentation approach successfully predicted the non-linear material properties of the heel pad without iterative finite element calculation. The force-displacement curve obtained in the present study was found to be situated lower than those identified in previous studies. The proposed framework for identifying the hyperelastic material parameters may facilitate the development of subject-specific FE modeling of the foot for possible clinical and ergonomic applications. Copyright © 2016 Elsevier Ltd. All rights reserved.

  8. Design of Low-Noise Output Amplifiers for P-channel Charge-Coupled Devices Fabricated on High-Resistivity Silicon

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Haque, S; Frost, F Dion R.; Groulx, R

    2011-12-22

    We describe the design and optimization of low-noise, single-stage output amplifiers for p-channel charge-coupled devices (CCDs) used for scientific applications in astronomy and other fields. The CCDs are fabricated on high-resistivity, 4000–5000 -cm, n-type silicon substrates. Single-stage amplifiers with different output structure designs and technologies have been characterized. The standard output amplifier is designed with an n{sup +} polysilicon gate that has a metal connection to the sense node. In an effort to lower the output amplifier readout noise by minimizing the capacitance seen at the sense node, buried-contact technology has been investigated. In this case, the output transistor hasmore » a p{sup +} polysilicon gate that connects directly to the p{sup +} sense node. Output structures with buried-contact areas as small as 2 μm × 2 μm are characterized. In addition, the geometry of the source-follower transistor was varied, and we report test results on the conversion gain and noise of the various amplifier structures. By use of buried-contact technology, better amplifier geometry, optimization of the amplifier biases and improvements in the test electronics design, we obtain a 45% reduction in noise, corresponding to 1.7 e{sup -} rms at 70 kpixels/sec.« less

  9. Dynamic kinematic responses of female volunteers in rear impacts and comparison to previous male volunteer tests.

    PubMed

    Carlsson, Anna; Linder, Astrid; Davidsson, Johan; Hell, Wolfram; Schick, Sylvia; Svensson, Mats

    2011-08-01

    The objective was to quantify dynamic responses of 50th percentile females in rear impacts and compare to those from similar tests with males. The results will serve as a basis for future work with models, criteria, and safety systems. A rear impact sled test series with 8 female volunteers was performed at velocity changes of 5 and 7 km/h. The following dynamic response corridors were generated for the head, T1 (first thoracic vertebra) and head relative to T1: (1) accelerations in posterior-anterior direction, (2) horizontal and vertical displacements, (3) angular displacements for 6 females close to the 50th percentile in size. Additionally, the head-to-head restraint distance and contact time and neck injury criterion (NIC) were extracted from the data set. These data were compared to results from previously performed male volunteer tests, representing the 50th percentile male, in equivalent test conditions. T-tests were performed with the statistical significance level of .05 to quantify the significance of the parameter value differences for the males and females. At 7 km/h, the females showed 29 percent earlier head-to-head restraint contact time (p = .0072); 27 percent shorter horizontal rearward head displacement (p = .0017); 36 percent narrower head extension angle (p = .0281); and 52 percent lower NIC value (p = .0239) than the males in previous tests. This was mainly due to 35 percent shorter initial head-to-head restraint distance for the females (p = .0125). The peak head acceleration in the posterior-anterior direction was higher and occurred earlier for the females. The overall result indicated differences in the dynamic response for the female and male volunteers. The results could be used in developing and evaluating a mechanical and/or mathematical average-sized female dummy model for rear impact safety assessment. These models can be used as a tool in the design of protective systems and for further development and evaluation of injury criteria.

  10. Evaporation-induced flow in an inviscid liquid line at any contact angle

    NASA Astrophysics Data System (ADS)

    Petsi, A. J.; Burganos, V. N.

    2006-04-01

    The problem of potential flow inside an evaporating liquid line, shaped as an infinitely long cylindrical segment lying on a flat surface, is considered and an analytical solution is obtained for any contact angle in (0,π) . In this way, microflow details inside linear liquid bodies evaporating on hydrophilic, hydrophobic, and strongly hydrophobic substrates can now be obtained. The mathematical formulation employs the velocity potential and stream function formulations in bipolar coordinates and the solution is obtained using the technique of Fourier transform. Both pinned and depinned contact lines are considered. The solution is applicable to any evaporation mechanism but for illustration purposes numerical results are presented here for the particular case of kinetically controlled evaporation. For hydrophilic substrates, the flow inside the evaporating liquid line is directed towards the edges for pinned contact lines, thus, promoting a coffee stain effect. The opposite flow direction is observed for depinned contact lines. However, for strongly hydrophobic substrates, flow is directed outwards for both pinned and depinned contact lines, but owing to its low magnitude compared to that on hydrophilic substrates, a craterlike colloidal deposit should be expected rather than a ringlike deposit, in agreement with experimental observations.

  11. Tibiofemoral contact mechanics following a horizontal cleavage lesion in the posterior horn of the medial meniscus.

    PubMed

    Arno, Sally; Bell, Christopher P; Uquillas, Carlos; Borukhov, Ilya; Walker, Peter S

    2015-04-01

    The purpose of this study was to determine if a horizontal cleavage lesion (HCL) of the posterior horn of the medial meniscus would result in changes to tibiofemoral contact mechanics, as measured by peak contact pressure and contact area, which can lead to cartilage degeneration. To study this, 10 cadaveric knees were tested in a rig where forces were applied (500 N Compression, 100 N shear, 2.5 Nm Torque) and the knee dynamically flexed from -5° to 135°, as peak contact pressure and contact area were recorded. After testing of the intact knee, a horizontal cleavage lesion was created arthroscopically and testing repeated. The Wilcoxon signed-rank test was used to determine if there were differences in peak contact pressure and contact area between the intact knee and that with the HCL. A statistically significant increase in peak contact pressure of 13%, on average, and a decrease in contact area of 6%, on average, was noted following the HCL. This suggests that a horizontal cleavage lesion will result in small but statistically significant changes in tibiofemoral contact mechanics which may lead to cartilage degeneration. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.

  12. Determination of contact angle from the maximum height of enlarged drops on solid surfaces

    NASA Astrophysics Data System (ADS)

    Behroozi, F.

    2012-04-01

    Measurement of the liquid/solid contact angle provides useful information on the wetting properties of fluids. In 1870, the German physicist Georg Hermann Quincke (1834-1924) published the functional relation between the maximum height of an enlarged drop and its contact angle. Quincke's relation offered an alternative to the direct measurement of contact angle, which in practice suffers from several experimental uncertainties. In this paper, we review Quincke's original derivation and show that it is based on a hidden assumption. We then present a new derivation that exposes this assumption and clarifies the conditions under which Quincke's relation is valid. To explore Quincke's relation experimentally, we measure the maximum height of enlarged water drops on several substrates and calculate the contact angle in each case. Our results are in good agreement with contact angles measured directly from droplet images.

  13. Contact problem for an elastic reinforcement bonded to an elastic plate

    NASA Technical Reports Server (NTRS)

    Erdogan, F.; Civelek, M. B.

    1974-01-01

    The contact problem for a thin elastic reinforcement bonded to an elastic plate is considered. The stiffening layer is treated as an elastic membrane and the base plate is assumed to be an elastic continuum. The bonding between the two materials is assumed to be either one of direct adhesion or through a thin adhesive layer which is treated as a shear spring. The solution for the simple case in which both the stiffener and the base plate are treated as membranes is also given. The contact stress is obtained for a series of numerical examples. In the direct adhesion case the contact stress becomes infinite at the stiffener ends with a typical square root singularity for the continuum model and behaving as a delta function for the membrane model. In the case of bonding through an adhesive layer the contact stress becomes finite and continuous along the entire contact area.

  14. Computerized Generation and Simulation of Meshing and Contact of New Type of Novikov-Wildhaber Helical Gears

    NASA Technical Reports Server (NTRS)

    Litvin, Faydor L.; Feng, Pin-Hao; Lagutin, Sergei A.

    2000-01-01

    In this report, we propose a new geometry for low-noise, increased-strength helical gears of the Novikov-Wildhaber type. Contact stresses are reduced as a result of their convex-concave gear tooth surfaces. The gear tooth surfaces are crowned in the profile direction to localize bearing contact and in the longitudinal direction to obtain a parabolic function of transmission errors. Such a function results in the reduction of noise and vibrations. Methods for the generation of the proposed gear tooth surfaces by grinding and hobbing are considered, and a tooth contact analysis (TCA) computer program to simulate meshing and contact is applied. The report also investigates the influence of misalignment on transmission errors and shift of bearing contact. Numerical examples to illustrate the developed approaches are proposed. The proposed geometry was patented by Ford/UIC (Serial Number 09-340-824, pending) on June 28, 1999.

  15. Membrane Contact Sites: Complex Zones for Membrane Association and Lipid Exchange

    PubMed Central

    Quon, Evan; Beh, Christopher T.

    2015-01-01

    Lipid transport between membranes within cells involves vesicle and protein carriers, but as agents of nonvesicular lipid transfer, the role of membrane contact sites has received increasing attention. As zones for lipid metabolism and exchange, various membrane contact sites mediate direct associations between different organelles. In particular, membrane contact sites linking the plasma membrane (PM) and the endoplasmic reticulum (ER) represent important regulators of lipid and ion transfer. In yeast, cortical ER is stapled to the PM through membrane-tethering proteins, which establish a direct connection between the membranes. In this review, we consider passive and facilitated models for lipid transfer at PM–ER contact sites. Besides the tethering proteins, we examine the roles of an additional repertoire of lipid and protein regulators that prime and propagate PM–ER membrane association. We conclude that instead of being simple mediators of membrane association, regulatory components of membrane contact sites have complex and multilayered functions. PMID:26949334

  16. 21 CFR 882.1570 - Powered direct-contact temperature measurement device.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Powered direct-contact temperature measurement device. 882.1570 Section 882.1570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882...

  17. 21 CFR 882.1570 - Powered direct-contact temperature measurement device.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Powered direct-contact temperature measurement device. 882.1570 Section 882.1570 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Diagnostic Devices § 882...

  18. Is there a doctor in the house? : The presence of physicians in the direct-to-consumer genetic testing context.

    PubMed

    Howard, Heidi Carmen; Borry, Pascal

    2012-04-01

    Over the last couple of years, many commercial companies, the majority of which are based in the USA, have been advertising and offering direct-to-consumer (DTC) genetic testing services outside of the established health care system, and often without any involvement from a health care professional. In the last year, however, a number of DTC genetic testing companies have changed their provision model such that consumers must now contact a health care professional before being able to order the genetic testing service. In discussing the advent of this new model of service provision, this article also reviews the ethical and social issues surrounding DTC genetic testing and addresses the potential motivations for change, some barriers to achieving truly appropriate medical supervision and the present reality of DTC genetic testing for some psychiatric and neurological disorders. Since the advent of these commercial activities, critics have pointed a finger at the lack of medical supervision surrounding these services. The discussion herein, however, reveals how difficult it may be, despite the addition of a physician, to actually achieve adequate medical supervision within the present context of DTC genetic testing.

  19. [The use of an opect optic system in neurosurgical practice].

    PubMed

    Kalinovskiy, A V; Rzaev, D A; Yoshimitsu, K

    2018-01-01

    Modern neurosurgical practice is impossible without access to various information sources. The use of MRI and MSCT data during surgery is an integral part of the neurosurgeon's daily practice. Devices capable of managing an image viewer system without direct contact with equipment simplify working in the operating room. To test operation of a non-contact MRI and MSCT image viewer system in the operating room and to evaluate the system effectiveness. An Opect non-contact image management system developed at the Tokyo Women's Medical University was installed in one of the operating rooms of the Novosibirsk Federal Center of Neurosurgery in 2014. In 2015, the Opect system was used by operating surgeons in 73 surgeries performed in the same operating room. The system effectiveness was analyzed based on a survey of surgeons. The non-contact image viewer system occurred to be easy-to-learn for the personnel to operate this system, easy-to-manage it, and easy-to-present visual information during surgery. Application of the Opect system simplifies work with neuroimaging data during surgery. The surgeon can independently view series of relevant MRI and MSCT scans without any assistance.

  20. Relative contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance.

    PubMed

    Lepley, Casey R; Throckmorton, Gaylord S; Ceen, Richard F; Buschang, Peter H

    2011-05-01

    The purpose of this study was to explore the contributions of occlusion, maximum bite force, and chewing cycle kinematics to masticatory performance. A prospective cross-sectional study was performed on 30 subjects with Class I occlusion. Masticatory performance was measured with the test food Cuttersil (Heraeus Kulzer, South Bend, Ind) and the fractional-sieve technique. Blu-Mousse (Parkell Biomaterials, Farmingdale, NY) bite registrations were used to measure occlusal contact areas. The American Board of Orthodontics occlusal discrepancies were measured on the subjects' dental models. Maximum bite forces were recorded with a custom transducer, and 3-dimensional chewing cycle kinematics were tracked with an opto-electric computer system and Optotrak software (Northern Digital, Waterloo, Ontario, Canada). Masticatory performance was most closely correlated with occlusal contact area, indicating larger contact areas in subjects with better performance. Occlusal contact area and occlusal discrepancies were also related to bite force and chewing cycle kinematics. Maximum bite force was positively related with masticatory performance. Although masticatory performance is related, both directly and indirectly, to a number of morphologic and functional factors, it is most closely related to occlusal factors. Copyright © 2011 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  1. Periocular dermatitis: a report of 401 patients.

    PubMed

    Temesvári, E; Pónyai, G; Németh, I; Hidvégi, B; Sas, A; Kárpáti, S

    2009-02-01

    Periocular contact dermatitis may appear as contact conjunctivitis, contact allergic and/or irritative eyelid and periorbital dermatitis, or a combination of these symptoms. The clinical symptoms may be induced by several environmental and therapeutic contact allergens. The aim of the present study was to map the eliciting contact allergens in 401 patients with periocular dermatitis (PD) by patch testing with environmental and ophthalmic contact allergens. Following the methodics of international requirements, 401 patients were tested with contact allergens of the standard environmental series, 133 of 401 patients with the Brial ophthalmic basic and supplementary series as well. Contact hypersensitivity was detected in 34.4% of the patients. Highest prevalence was seen in cases of PD without other symptoms (51.18%), in patients of PD associated with ophthalmic complaints (OC; 30.4%), and PD associated with atopic dermatitis (AD; 27.9%). In the subgroup of PD associated with seborrhoea (S) and rosacea (R), contact hypersensitivity was confirmed in 17.6%. Most frequent sensitisers were nickel sulphate (in 8.9% of the tested 401 patients), fragrance mix I (4.5%), balsam of Peru (4.0%), paraphenylendiamine (PPD) (3.7%), and thiomersal (3.5%). By testing ophthalmic allergens, contact hypersensitivity was observed in nine patients (6.7% of the tested 133 patients). The most common confirmed ophthalmic allergens were cocamidopropyl betaine, idoxuridine, phenylephrine hydrochloride, Na chromoglycinate, and papaine. Patients with symptoms of PD were tested from 1996 to 2006. The occurence of contact hypersensitivity in PD patients was in present study 34.4%. A relatively high occurrence was seen in cases of PD without other symptoms, in PD + OC and in PD + AD patients. The predominance of environmental contact allergens was remarkable: most frequent sensitizers were nickel sulphate, fragrance mix I, balsam of Peru, thiomersal, and PPD. The prevalence of contact hypersensitivity to ophthalmic allergens did not exceed l.5%.

  2. Nosocomial transmission of Ebola virus disease on pediatric and maternity wards: Bombali and Tonkolili, Sierra Leone, 2014.

    PubMed

    Dunn, Angela C; Walker, Tiffany A; Redd, John; Sugerman, David; McFadden, Jevon; Singh, Tushar; Jasperse, Joseph; Kamara, Brima Osaio; Sesay, Tom; McAuley, James; Kilmarx, Peter H

    2016-03-01

    In the largest Ebola virus disease (EVD) outbreak in history, nosocomial transmission of EVD increased spread of the disease. We report on 2 instances in Sierra Leone where patients unknowingly infected with EVD were admitted to a general hospital ward (1 pediatric ward and 1 maternity ward), exposing health care workers, caregivers, and other patients to EVD. Both patients died on the general wards, and were later confirmed as being infected with EVD. We initiated contact tracing and assessed risk factors for secondary infections to guide containment recommendations. We reviewed medical records to establish the index patients' symptom onset. Health care workers, patients, and caregivers were interviewed to determine exposures and personal protective equipment (PPE) use. Contacts were monitored daily for EVD symptoms. Those who experienced EVD symptoms were isolated and tested. Eighty-two contacts were identified: 64 health care workers, 7 caregivers, 4 patients, 4 newborns, and 3 children of patients. Seven contacts became symptomatic and tested positive for EVD: 2 health care workers (1 nurse and 1 hospital cleaner), 2 caregivers, 2 newborns, and 1 patient. The infected nurse placed an intravenous catheter in the pediatric index patient with only short gloves PPE and the hospital cleaner cleaned the operating room of the maternity ward index patient wearing short gloves PPE. The maternity ward index patient's caregiver and newborn were exposed to her body fluids. The infected patient and her newborn shared the ward and latrine with the maternity ward index patient. Hospital staff members did not use adequate PPE. Caregivers were not offered PPE. Delayed recognition of EVD and inadequate PPE likely led to exposures and secondary infections. Earlier recognition of EVD and adequate PPE might have reduced direct contact with body fluids. Limiting nonhealth-care worker contact, improving access to PPE, and enhancing screening methods for pregnant women, children, and inpatients may help decrease EVD transmission in general health care settings. Published by Elsevier Inc.

  3. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn directly...

  4. 21 CFR 886.5916 - Rigid gas permeable contact lens.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... 21 Food and Drugs 8 2011-04-01 2011-04-01 false Rigid gas permeable contact lens. 886.5916 Section... (CONTINUED) MEDICAL DEVICES OPHTHALMIC DEVICES Therapeutic Devices § 886.5916 Rigid gas permeable contact lens. (a) Identification. A rigid gas permeable contact lens is a device intended to be worn directly...

  5. 77 FR 12903 - 60-Day Notice of Proposed Information Collection: DS-158, Contact Information and Work History...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-03-02

    ..., Contact Information and Work History for Nonimmigrant Visa Applicant ACTION: Notice of request for public... with the Paperwork Reduction Act of 1995. Title of Information Collection: Contact Information and Work... FURTHER INFORMATION CONTACT: Direct requests for additional information regarding the collection listed in...

  6. Endoplasmic Reticulum-Plasma Membrane Contact Sites.

    PubMed

    Saheki, Yasunori; De Camilli, Pietro

    2017-06-20

    The endoplasmic reticulum (ER) has a broad localization throughout the cell and forms direct physical contacts with all other classes of membranous organelles, including the plasma membrane (PM). A number of protein tethers that mediate these contacts have been identified, and study of these protein tethers has revealed a multiplicity of roles in cell physiology, including regulation of intracellular Ca 2+ dynamics and signaling as well as control of lipid traffic and homeostasis. In this review, we discuss the cross talk between the ER and the PM mediated by direct contacts. We review factors that tether the two membranes, their properties, and their dynamics in response to the functional state of the cell. We focus in particular on the role of ER-PM contacts in nonvesicular lipid transport between the two bilayers mediated by lipid transfer proteins.

  7. Alterations in knee contact forces and centers in stance phase of gait: A detailed lower extremity musculoskeletal model.

    PubMed

    Marouane, H; Shirazi-Adl, A; Adouni, M

    2016-01-25

    Evaluation of contact forces-centers of the tibiofemoral joint in gait has crucial biomechanical and pathological consequences. It involves however difficulties and limitations in in vitro cadaver and in vivo imaging studies. The goal is to estimate total contact forces (CF) and location of contact centers (CC) on the medial and lateral plateaus using results computed by a validated finite element model simulating the stance phase of gait for normal as well as osteoarthritis, varus-valgus and posterior tibial slope altered subjects. Using foregoing contact results, six methods commonly used in the literature are also applied to estimate and compare locations of CC at 6 periods of stance phase (0%, 5%, 25%, 50%, 75% and 100%). TF joint contact forces are greater on the lateral plateau very early in stance and on the medial plateau thereafter during 25-100% stance periods. Large excursions in the location of CC (>17mm), especially on the medial plateau in the mediolateral direction, are computed. Various reported models estimate quite different CCs with much greater variations (~15mm) in the mediolateral direction on both plateaus. Compared to our accurately computed CCs taken as the gold standard, the centroid of contact area algorithm yielded least differences (except in the mediolateral direction on the medial plateau at ~5mm) whereas the contact point and weighted center of proximity algorithms resulted overall in greatest differences. Large movements in the location of CC should be considered when attempting to estimate TF compartmental contact forces in gait. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Effects of Strand Lay Direction and Crossing Angle on Tribological Behavior of Winding Hoist Rope.

    PubMed

    Chang, Xiang-Dong; Peng, Yu-Xing; Zhu, Zhen-Cai; Gong, Xian-Sheng; Yu, Zhang-Fa; Mi, Zhen-Tao; Xu, Chun-Ming

    2017-06-09

    Friction and wear behavior exists between hoisting ropes that are wound around the drums of a multi-layer winding hoist. It decreases the service life of ropes and threatens mine safety. In this research, a series of experiments were conducted using a self-made test rig to study the effects of the strand lay direction and crossing angle on the winding rope's tribological behavior. Results show that the friction coefficient in the steady-state period shows a decreasing tendency with an increase of the crossing angle in both cross directions, but the variation range is different under different cross directions. Using thermal imaging, the high temperature regions always distribute along the strand lay direction in the gap between adjacent strands, as the cross direction is the same with the strand lay direction (right cross contact). Additionally, the temperature rise in the steady-state increases with the increase of the crossing angle in both cross directions. The differences of the wear scar morphology are obvious under different cross directions, especially for the large crossing angle tests. In the case of right cross, the variation range of wear mass loss is larger than that in left cross. The damage that forms on the wear surface is mainly ploughing, pits, plastic deformation, and fatigue fracture. The major wear mechanisms are adhesive wear, and abrasive and fatigue wear.

  9. Effects of Strand Lay Direction and Crossing Angle on Tribological Behavior of Winding Hoist Rope

    PubMed Central

    Chang, Xiang-dong; Peng, Yu-xing; Zhu, Zhen-cai; Gong, Xian-sheng; Yu, Zhang-fa; Mi, Zhen-tao; Xu, Chun-ming

    2017-01-01

    Friction and wear behavior exists between hoisting ropes that are wound around the drums of a multi-layer winding hoist. It decreases the service life of ropes and threatens mine safety. In this research, a series of experiments were conducted using a self-made test rig to study the effects of the strand lay direction and crossing angle on the winding rope’s tribological behavior. Results show that the friction coefficient in the steady-state period shows a decreasing tendency with an increase of the crossing angle in both cross directions, but the variation range is different under different cross directions. Using thermal imaging, the high temperature regions always distribute along the strand lay direction in the gap between adjacent strands, as the cross direction is the same with the strand lay direction (right cross contact). Additionally, the temperature rise in the steady-state increases with the increase of the crossing angle in both cross directions. The differences of the wear scar morphology are obvious under different cross directions, especially for the large crossing angle tests. In the case of right cross, the variation range of wear mass loss is larger than that in left cross. The damage that forms on the wear surface is mainly ploughing, pits, plastic deformation, and fatigue fracture. The major wear mechanisms are adhesive wear, and abrasive and fatigue wear. PMID:28772992

  10. Analysis of the axisymmetric indentation of a semi-infinite piezoelectric material: The evaluation of the contact stiffness and the effective piezoelectric constant

    NASA Astrophysics Data System (ADS)

    Yang, Fuqian

    2008-04-01

    A general solution of the axisymmetric indentation is obtained in the closed form for a semi-infinite, transverse isotropic piezoelectric material by a rigid-conducting indenter of arbitrary-axisymmetric profile. Explicit relationships are derived for dependences of the indentation depth and the indentation-induced charge on indentation force and applied electrical potential. Simple formulas are obtained for contact stiffness and effective piezoelectric constant, which can be used in indentation test and piezoresponse force microscopy to analyze the elastic and piezoelectric responses of piezoelectric materials. Depending on the direction of electric field (the potential difference), the electric field can either increase or suppress indentation deformation. The corresponding results are given for cylindrical, conical, and paraboloidal indenters.

  11. Electrode effects in dielectric spectroscopy measurements on (Nb+In) co-doped TiO2

    NASA Astrophysics Data System (ADS)

    Crandles, D. A.; Yee, S. M. M.; Savinov, M.; Nuzhnyy, D.; Petzelt, J.; Kamba, S.; Prokeš, J.

    2016-04-01

    Recently, several papers reported the discovery of giant permittivity and low dielectric loss in (Nb+In) co-doped TiO2. A series of tests was performed which included the measurement of the frequency dependence of the dielectric permittivity and alternating current (ac) conductivity of co-doped (Nb+In)TiO2 as a function of electrode type, sample thickness, and temperature. The data suggest that the measurements are strongly affected by the electrodes. The consistency between four-contact van der Pauw direct current conductivity measurements and bulk conductivity values extracted from two-contact ac conductivity measurements suggest that the values of colossal permittivity are, at least in part, a result of Schottky barrier depletion widths that depend on electrode type and temperature.

  12. Effect of direct eye contact in PTSD related to interpersonal trauma: an fMRI study of activation of an innate alarm system.

    PubMed

    Steuwe, Carolin; Daniels, Judith K; Frewen, Paul A; Densmore, Maria; Pannasch, Sebastian; Beblo, Thomas; Reiss, Jeffrey; Lanius, Ruth A

    2014-01-01

    In healthy individuals, direct eye contact initially leads to activation of a fast subcortical pathway, which then modulates a cortical route eliciting social cognitive processes. The aim of this study was to gain insight into the neurobiological effects of direct eye-to-eye contact using a virtual reality paradigm in individuals with posttraumatic stress disorder (PTSD) related to prolonged childhood abuse. We examined 16 healthy comparison subjects and 16 patients with a primary diagnosis of PTSD using a virtual reality functional magnetic resonance imaging paradigm involving direct vs averted gaze (happy, sad, neutral) as developed by Schrammel et al. in 2009. Irrespective of the displayed emotion, controls exhibited an increased blood oxygenation level-dependent response during direct vs averted gaze within the dorsomedial prefrontal cortex, left temporoparietal junction and right temporal pole. Under the same conditions, individuals with PTSD showed increased activation within the superior colliculus (SC)/periaqueductal gray (PAG) and locus coeruleus. Our findings suggest that healthy controls react to the exposure of direct gaze with an activation of a cortical route that enhances evaluative 'top-down' processes underlying social interactions. In individuals with PTSD, however, direct gaze leads to sustained activation of a subcortical route of eye-contact processing, an innate alarm system involving the SC and the underlying circuits of the PAG.

  13. Effect of direct eye contact in PTSD related to interpersonal trauma: an fMRI study of activation of an innate alarm system

    PubMed Central

    Steuwe, Carolin; Daniels, Judith K.; Frewen, Paul A.; Densmore, Maria; Pannasch, Sebastian; Beblo, Thomas; Reiss, Jeffrey; Lanius, Ruth A.

    2014-01-01

    In healthy individuals, direct eye contact initially leads to activation of a fast subcortical pathway, which then modulates a cortical route eliciting social cognitive processes. The aim of this study was to gain insight into the neurobiological effects of direct eye-to-eye contact using a virtual reality paradigm in individuals with posttraumatic stress disorder (PTSD) related to prolonged childhood abuse. We examined 16 healthy comparison subjects and 16 patients with a primary diagnosis of PTSD using a virtual reality functional magnetic resonance imaging paradigm involving direct vs averted gaze (happy, sad, neutral) as developed by Schrammel et al. in 2009. Irrespective of the displayed emotion, controls exhibited an increased blood oxygenation level-dependent response during direct vs averted gaze within the dorsomedial prefrontal cortex, left temporoparietal junction and right temporal pole. Under the same conditions, individuals with PTSD showed increased activation within the superior colliculus (SC)/periaqueductal gray (PAG) and locus coeruleus. Our findings suggest that healthy controls react to the exposure of direct gaze with an activation of a cortical route that enhances evaluative ‘top–down’ processes underlying social interactions. In individuals with PTSD, however, direct gaze leads to sustained activation of a subcortical route of eye-contact processing, an innate alarm system involving the SC and the underlying circuits of the PAG. PMID:22977200

  14. Non-contact modal testing by the electromagnetic acoustic principle: Applications to bending and torsional vibrations of metallic pipes

    NASA Astrophysics Data System (ADS)

    Kim, Hongjin; Park, Chan Il; Lee, Sun Ho; Kim, Yoon Young

    2013-02-01

    This work aims to investigate a possibility of non-contact vibration modal testing for bending and torsional motions of cylindrical bodies such as pipes. Here, a transducer operated by the electromagnetic acoustic coupling principle is newly devised. Depending on vibration modes, bending or torsional, different magnetic circuit configurations are employed to fabricate the transducer. The main characteristic of the proposed transducer is non-contact vibration generation in a test specimen without any mechanical movement of the actuating unit. It can be also used as a non-contact sensing unit if necessary. The validity and the performance of the proposed non-contact modal testing method are checked with several experiments.

  15. Genital and Extragenital Gonorrhea and Chlamydia in Children and Adolescents Evaluated for Sexual Abuse.

    PubMed

    Kellogg, Nancy D; Melville, John D; Lukefahr, James L; Nienow, Shalon M; Russell, Edward L

    2017-01-09

    The aim of this study was to describe the use of a nucleic acid amplification test in detecting genital and extragenital Neisseria gonorrhoeae (NG) and Chlamydia trachomatis (CT) in children and adolescents assessed for sexual abuse/assault. The charts of children aged 0 to 17 years, consecutively evaluated for sexual victimization, in emergency department and outpatient settings were reviewed. Data extracted included age, sex, type of sexual contact, anogenital findings, previous sexual contact, toxicology results, and sites tested for NG and CT. Of the 1319 patients who were tested, 579 were tested at more than 1 site, and 120 had at least 1 infected site. Chlamydia trachomatis was identified in 104 patients, and NG was found in 33. In bivariate analysis, a positive test was associated with female sex, age older than 11 years, previous sexual contact, acute or healed genital injury, drug/alcohol intoxication, and examination within 72 hours of sexual contact. Fifty-one patients had positive anal tests, and 24 had positive oral tests. More than 75% of patients with positive extragenital tests had additional positive tests or anogenital injury. Most with a positive anal (59%) or oral (77%) test did not report that the assailant's genitals came into contact with that site. Positive tests for NG and CT in patients evaluated for sexual victimization may represent infection from sexual contact, contiguous spread of infection, or the presence of infected assailant secretions. Relying on patient reports of symptoms, or types of sexual contact, to determine need for testing may miss NG and CT infections in patients evaluated for sexual victimization.

  16. Alternative Chemical Cleaning Methods for High Level Waste Tanks: Actual Waste Testing with SRS Tank 5F Sludge

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    King, William D.; Hay, Michael S.

    Solubility testing with actual High Level Waste tank sludge has been conducted in order to evaluate several alternative chemical cleaning technologies for the dissolution of sludge residuals remaining in the tanks after the exhaustion of mechanical cleaning and sludge sluicing efforts. Tests were conducted with archived Savannah River Site (SRS) radioactive sludge solids that had been retrieved from Tank 5F in order to determine the effectiveness of an optimized, dilute oxalic/nitric acid cleaning reagent toward dissolving the bulk non-radioactive waste components. Solubility tests were performed by direct sludge contact with the oxalic/nitric acid reagent and with sludge that had beenmore » pretreated and acidified with dilute nitric acid. For comparison purposes, separate samples were also contacted with pure, concentrated oxalic acid following current baseline tank chemical cleaning methods. One goal of testing with the optimized reagent was to compare the total amounts of oxalic acid and water required for sludge dissolution using the baseline and optimized cleaning methods. A second objective was to compare the two methods with regard to the dissolution of actinide species known to be drivers for SRS tank closure Performance Assessments (PA). Additionally, solubility tests were conducted with Tank 5 sludge using acidic and caustic permanganate-based methods focused on the “targeted” dissolution of actinide species.« less

  17. The direction of fluid flow during contact metamorphism of siliceous carbonate rocks: new data for the Monzoni and Predazzo aureoles, northern Italy, and a global review

    NASA Astrophysics Data System (ADS)

    Ferry, John M.; Wing, Boswell A.; Penniston-Dorland, Sarah C.; Rumble, Douglas

    2002-03-01

    Periclase formed in siliceous dolomitic marbles during contact metamorphism in the Monzoni and Predazzo aureoles, the Dolomites, northern Italy, by infiltration of the carbonate rocks by chemically reactive, H2O-rich fluids at 500 bar and 565-710 °C. The spatial distribution of periclase and oxygen isotope compositions is consistent with reactive fluid flow that was primarily vertical and upward in both aureoles with time-integrated flux ~5,000 and ~300 mol fluid/cm2 rock in the Monzoni and Predazzo aureoles, respectively. The new results for Monzoni and Predazzo are considered along with published studies of 13 other aureoles to draw general conclusions about the direction, amount, and controls on the geometry of reactive fluid flow during contact metamorphism of siliceous carbonate rocks. Flow in 12 aureoles was primarily vertically upward with and without a horizontal component directed away from the pluton. Fluid flow in two of the other three was primarily horizontal, directed from the pluton into the aureole. The direction of flow in the remaining aureole is uncertain. Earlier suggestions that fluid flow is often horizontal, directed toward the pluton, are likely explained by an erroneous assumption that widespread coexisting mineral reactants and products represent arrested prograde decarbonation reactions. With the exception of three samples from one aureole, time-integrated fluid flux was in the range 102-104 mol/cm2. Both the amount and direction of fluid flow are consistent with hydrodynamic models of contact metamorphism. The orientation of bedding and lithologic contacts appears to be the principal control over whether fluid flow was either primarily vertical or horizontal. Other pre-metamorphic structures, including dikes, faults, fold hinges, and fracture zones, served to channel fluid flow as well.

  18. The direction of fluid flow during contact metamorphism of siliceous carbonate rocks: new data for the Monzoni and Predazzo aureoles, northern Italy, and a global review

    NASA Astrophysics Data System (ADS)

    Ferry, John; Wing, Boswell; Penniston-Dorland, Sarah; Rumble, Douglas

    2001-11-01

    Periclase formed in siliceous dolomitic marbles during contact metamorphism in the Monzoni and Predazzo aureoles, the Dolomites, northern Italy, by infiltration of the carbonate rocks by chemically reactive, H2O-rich fluids at 500 bar and 565-710 °C. The spatial distribution of periclase and oxygen isotope compositions is consistent with reactive fluid flow that was primarily vertical and upward in both aureoles with time-integrated flux 5,000 and 300 mol fluid/cm2 rock in the Monzoni and Predazzo aureoles, respectively. The new results for Monzoni and Predazzo are considered along with published studies of 13 other aureoles to draw general conclusions about the direction, amount, and controls on the geometry of reactive fluid flow during contact metamorphism of siliceous carbonate rocks. Flow in 12 aureoles was primarily vertically upward with and without a horizontal component directed away from the pluton. Fluid flow in two of the other three was primarily horizontal, directed from the pluton into the aureole. The direction of flow in the remaining aureole is uncertain. Earlier suggestions that fluid flow is often horizontal, directed toward the pluton, are likely explained by an erroneous assumption that widespread coexisting mineral reactants and products represent arrested prograde decarbonation reactions. With the exception of three samples from one aureole, time-integrated fluid flux was in the range 102-104 mol/cm2. Both the amount and direction of fluid flow are consistent with hydrodynamic models of contact metamorphism. The orientation of bedding and lithologic contacts appears to be the principal control over whether fluid flow was either primarily vertical or horizontal. Other pre-metamorphic structures, including dikes, faults, fold hinges, and fracture zones, served to channel fluid flow as well.

  19. Laser measurement of respiration activity in preterm infants: Monitoring of peculiar events

    NASA Astrophysics Data System (ADS)

    Scalise, L.; Marchionni, P.; Ercoli, I.; Tomasini, E. P.

    2012-09-01

    The Neonatal Intensive Care Unit (NICU) is a part of a pediatric hospital dedicated to the care of ill or pre-term patients . NICU's patients are underweight and most of the time they need cardiac and respiratory support therapies; they are placed in incubators or in cribs maintaining target environmental and body temperatures and protecting patients from bacteria and virus. Patients are continuously monitored for long period of time (days or weeks) due to their possible several health conditions. the most common vital signs monitored are: respiration rate, heart rate, body temperature, blood saturation, etc. Most of the devices used for transducing such quantities in electronic signals - like spirometer or electrocardiogram (ECG) - are in direct contact with the patient and results, also in consideration of the specific patient, largely invasive. In this paper, we propose a novel measurement system for non-contact and non-invasive assessment of the respiration activity, with particular reference to the detection of peculiar respiration events of extreme interest in intensive care units, such as: irregular inspiration/expiration acts, hiccups and apneas. The sensing device proposed is the Laser Doppler Vibrometer (LDVi) which is an non contact, optical measurement system for the assessment of a surface velocity and displacement. In the past it has been demonstrated to be suitable to measure heart rate (HR) and respiration rate (RR) in adult and in preterm infant trough chest-wall displacements. The measurement system is composed by a LDVi system and a data acquisition board installed on a PC, with no direct contact with the patient. Tests have been conducted on 20 NICU patients, for a total of 7219 data sampled. Results show very high correlation (R=0.99) with the reference instrument used for the patient monitoring (mechanical ventilator), with an uncertainty < ±7 ms (k=2). Moreover, during the tests, some peculiar respiration events, have been recorded on 6 of the monitored patients: irregular inspiration/expiration acts (4), hiccups (1) and apneas (1). The proposed measurement method shows to be able to precisely detect the instantaneous respiration frequency of the patient, avoiding patient contact. Moreover the signal collected allow to identify irregularities in the patient respiration of different severity, allowing an optimized action of the care givers.

  20. 49 CFR 572.176 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...

  1. 49 CFR 572.176 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2014 CFR

    2014-10-01

    ... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...

  2. 49 CFR 572.176 - Knees and knee impact test procedure.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... procedure in subsection (c) of this section: (1) The peak resistance force as measured with the test probe.... (3) Align the test probe so that throughout its stroke and at contact with the knee it is within 2... contact between the impactor and the knee. (5) The test probe velocity at the time of contact shall be 2.1...

  3. Rectus sheath hematoma caused by non-contact strenuous exercise mimicking acute appendicitis.

    PubMed

    Oh, Je Hyeok; Kim, Tae Han; Cha, Sung Jae; Kim, Seung Ho

    2010-09-01

    A healthy 26-year-old man visited the Emergency Department due to right lower quadrant pain of 2 days' duration that developed after wakeboarding. There was no history of direct trauma to the abdomen. Physical examination revealed tenderness and rebound tenderness on the right lower quadrant area. There was no palpable abdominal mass. Computed tomography (CT) of the abdomen was undertaken to discern the causes of acute abdomen, including acute appendicitis. CT revealed a small-size rectus sheath hematoma beneath the lower end of the right rectus muscle. The patient was admitted for supportive care including pain control and was discharged with improvement after 5 days. Rectus sheath hematoma can be caused by not only a direct blow but also non-contact strenuous exercise, for example, wakeboarding in this case. Although the majority of rectus sheath hematomas are self-limiting, some can cause peritoneal irritation signs, mimicking acute abdomen, and eventually lead to unnecessary laparotomy without clinical suspicion and ancillary tests including CT scan and ultrasonography. Copyright © 2010 Elsevier Inc. All rights reserved.

  4. Coupling of fingertip somatosensory information to head and body sway

    NASA Technical Reports Server (NTRS)

    Jeka, J. J.; Schoner, G.; Dijkstra, T.; Ribeiro, P.; Lackner, J. R.

    1997-01-01

    Light touch contact of a fingertip with a stationary surface can provide orientation information that enhances control of upright stance. Slight changes in contact force at the fingertip provide sensory cues about the direction of body sway, allowing attenuation of sway. In the present study, we asked to which extent somatosensory cues are part of the postural control system, that is, which sensory signal supports this coupling? We investigated postural control not only when the contact surface was stationary, but also when it was moving rhythmically (from 0.1 to 0.5 Hz). In doing so, we brought somatosensory cues from the hand into conflict with other parts of the postural control system. Our focus was the temporal relationship between body sway and the contact surface. Postural sway was highly coherent with contact surface motion. Head and body sway assumed the frequency of the moving contact surface at all test frequencies. To account for these results, a simple model was formulated by approximating the postural control system as a second-order linear dynamical system. The influence of the touch stimulus was captured as the difference between the velocity of the contact surface and the velocity of body sway, multiplied by a coupling constant. Comparison of empirical results (relative phase, coherence, and gain) with model predictions supports the hypothesis of coupling between body sway and touch cues through the velocity of the somatosensory stimulus at the fingertip. One subject, who perceived movement of the touch surface, demonstrated weaker coupling than other subjects, suggesting that cognitive mechanisms introduce flexibility into the postural control scheme.

  5. Biomechanics and strain mapping in bone as related to immediately-loaded dental implants

    PubMed Central

    Du, Jing; Lee, Jihyun; Jang, Andrew; Gu, Allen; Hossaini-Zadeh, Mehran; Prevost, Richard; Curtis, Don; Ho, Sunita

    2015-01-01

    The effects of alveolar bone socket geometry and bone-implant contact on implant biomechanics, and resulting strain distributions in bone were investigated. Following extraction of lateral incisors on a cadaver mandible, immediate implants were placed and bone-implant contact area, stability and bone strain were measured. In situ biomechanical testing coupled with micro X-ray microscope (μ-XRM) illustrated less stiff bone-implant complexes (701-822 N/mm) compared with bone-periodontal ligament (PDL)-tooth complexes (791-913 N/mm). X-ray tomograms illustrated that the cause of reduced stiffness was due to reduced and limited bone-implant contact. Heterogeneous elemental composition of bone was identified by using energy dispersive X-ray spectroscopy (EDS). The novel aspect of this study was the application of a new experimental mechanics method, that is, digital volume correlation, which allowed mapping of strains in volumes of alveolar bone in contact with a loaded implant. The identified surface and subsurface strain concentrations were a manifestation of load transferred to bone through bone-implant contact based on bone-implant geometry, quality of bone, implant placement, and implant design. 3D strain mapping indicated that strain concentrations are not exclusive to the bone-implant contact regions, but also extend into bone not directly in contact with the implant. The implications of the observed strain concentrations are discussed in the context of mechanobiology. Although a plausible explanation of surgical complications for immediate implant treatment is provided, extrapolation of results is only warranted by future systematic studies on more cadaver specimens and/or in vivo small scale animal models. PMID:26162549

  6. A two-angle model of dynamic wetting in microscale capillaries under low capillary numbers with experiments.

    PubMed

    Lei, Da; Lin, Mian; Li, Yun; Jiang, Wenbin

    2018-06-15

    An accurate model of the dynamic contact angle θ d is critical for the calculation of capillary force in applications like enhanced oil recovery, where the capillary number Ca ranges from 10 -10 to 10 -5 and the Bond number Bo is less than 10 -4 . The rate-dependence of the dynamic contact angle under such conditions remains blurred, and is the main target of this study. Featuring with pressure control and interface tracking, the innovative experimental system presented in this work achieves the desired ranges of Ca and Bo, and enables the direct optical measurement of dynamic contact angles in capillaries as tiny as 40 × 20 (width × height) μm and 80 × 20 μm. The advancing and receding processes of wetting and nonwetting liquids were tested. The dynamic contact angle was confirmed velocity-independent with 10 -9  < Ca < 10 -5 (contact line velocity V = 0.135-490 μm/s) and it can be described by a two-angle model with desirable accuracy. A modified two-angle model was developed and an empirical form was obtained from experiments. For different liquids contacting the same surface, the advancing angle θ adv approximately equals the static contact angle θ o . The receding angle θ rec was found to be a linear function of θ adv , in good agreement with our and other experiments from the literature. Copyright © 2018 Elsevier Inc. All rights reserved.

  7. Passive Fetal Heart Monitoring System

    NASA Technical Reports Server (NTRS)

    Zuckerwar, Allan J. (Inventor); Mowrey, Dennis L. (Inventor)

    2003-01-01

    A fetal heart monitoring system and method for detecting and processing acoustic fetal heart signals transmitted by different signal transmission modes. One signal transmission mode, the direct contact mode, occurs in a first frequency band when the fetus is in direct contact with the maternal abdominal wall. Another signal transmission mode, the fluid propagation mode, occurs in a second frequency band when the fetus is in a recessed position with no direct contact with the maternal abdominal wall. The second frequency band is relatively higher than the first frequency band. The fetal heart monitoring system and method detect and process acoustic fetal heart signals that are in the first frequency band and in the second frequency band.

  8. Badgers prefer cattle pasture but avoid cattle: implications for bovine tuberculosis control.

    PubMed

    Woodroffe, Rosie; Donnelly, Christl A; Ham, Cally; Jackson, Seth Y B; Moyes, Kelly; Chapman, Kayna; Stratton, Naomi G; Cartwright, Samantha J

    2016-10-01

    Effective management of infectious disease relies upon understanding mechanisms of pathogen transmission. In particular, while models of disease dynamics usually assume transmission through direct contact, transmission through environmental contamination can cause different dynamics. We used Global Positioning System (GPS) collars and proximity-sensing contact-collars to explore opportunities for transmission of Mycobacterium bovis [causal agent of bovine tuberculosis] between cattle and badgers (Meles meles). Cattle pasture was badgers' most preferred habitat. Nevertheless, although collared cattle spent 2914 collar-nights in the home ranges of contact-collared badgers, and 5380 collar-nights in the home ranges of GPS-collared badgers, we detected no direct contacts between the two species. Simultaneous GPS-tracking revealed that badgers preferred land > 50 m from cattle. Very infrequent direct contact indicates that badger-to-cattle and cattle-to-badger M. bovis transmission may typically occur through contamination of the two species' shared environment. This information should help to inform tuberculosis control by guiding both modelling and farm management. © 2016 John Wiley & Sons Ltd/CNRS.

  9. Advances in cryogenic foam insulations.

    NASA Technical Reports Server (NTRS)

    Lemons, C. R.; Salmassy, O. K.; Watts, C. R.

    1971-01-01

    Description of a discretely oriented thread-reinforced polyurethane foam thermal insulation system for liquid hydrogen fuel tanks. The 3-D foam and glass liner composite is designed to be adhesively bonded to the inside surface of the tank wall and to be in direct contact with liquid hydrogen. All elements of this insulation composite are capable of sustaining the loads and environmental conditions imposed by testing under simulated Space Shuttle vehicle requirements at temperatures between -423 and +350 F.

  10. Direct physical contact between intercalated cells in the distal convoluted tubule and the afferent arteriole in mouse kidneys.

    PubMed

    Ren, Hao; Liu, Ning-Yu; Andreasen, Arne; Thomsen, Jesper S; Cao, Liu; Christensen, Erik I; Zhai, Xiao-Yue

    2013-01-01

    Recent physiological studies in the kidney proposed the existence of a secondary feedback mechanism termed 'crosstalk' localized after the macula densa. This newly discovered crosstalk contact between the nephron tubule and its own afferent arteriole may potentially revolutionize our understanding of renal vascular resistance and electrolyte regulation. However, the nature of such a crosstalk mechanism is still debated due to a lack of direct and comprehensive morphological evidence. Its exact location along the nephron, its prevalence among the different types of nephrons, and the type of cells involved are yet unknown. To address these issues, computer assisted 3-dimensional nephron tracing was applied in combination with direct immunohistochemistry on plastic sections and electron microscopy. 'Random' contacts in the cortex were identified by the tracing and excluded. We investigated a total of 168 nephrons from all cortical regions. The results demonstrated that the crosstalk contact existed, and that it was only present in certain nephrons (90% of the short-looped and 75% of the long-looped nephrons). The crosstalk contacts always occurred at a specific position--the last 10% of the distal convoluted tubule. Importantly, we demonstrated, for the first time, that the cells found in the tubule wall at the contact site were always type nonA-nonB intercalated cells. In conclusion, the present work confirmed the existence of a post macula densa physical crosstalk contact.

  11. Predicting complete loss to follow-up after a health-education program: number of absences and face-to-face contact with a researcher.

    PubMed

    Park, M J; Yamazaki, Yoshihiko; Yonekura, Yuki; Yukawa, Keiko; Ishikawa, Hirono; Kiuchi, Takahiro; Green, Joseph

    2011-10-27

    Research on health-education programs requires longitudinal data. Loss to follow-up can lead to imprecision and bias, and complete loss to follow-up is particularly damaging. If that loss is predictable, then efforts to prevent it can be focused on those program participants who are at the highest risk. We identified predictors of complete loss to follow-up in a longitudinal cohort study. Data were collected over 1 year in a study of adults with chronic illnesses who were in a program to learn self-management skills. Following baseline measurements, the program had one group-discussion session each week for six weeks. Follow-up questionnaires were sent 3, 6, and 12 months after the baseline measurement. A person was classified as completely lost to follow-up if none of those three follow-up questionnaires had been returned by two months after the last one was sent.We tested two hypotheses: that complete loss to follow-up was directly associated with the number of absences from the program sessions, and that it was less common among people who had had face-to-face contact with one of the researchers. We also tested predictors of data loss identified previously and examined associations with specific diagnoses.Using the unpaired t-test, the U test, Fisher's exact test, and logistic regression, we identified good predictors of complete loss to follow-up. The prevalence of complete loss to follow-up was 12.2% (50/409). Complete loss to follow-up was directly related to the number of absences (odds ratio; 95% confidence interval: 1.78; 1.49-2.12), and it was inversely related to age (0.97; 0.95-0.99). Complete loss to follow-up was less common among people who had met one of the researchers (0.51; 0.28-0.95) and among those with connective tissue disease (0.29; 0.09-0.98). For the multivariate logistic model the area under the ROC curve was 0.77. Complete loss to follow-up after this health-education program can be predicted to some extent from data that are easy to collect (age, number of absences, and diagnosis). Also, face-to-face contact with a researcher deserves further study as a way of increasing participation in follow-up, and health-education programs should include it.

  12. Eczema (For Parents)

    MedlinePlus

    ... the skin to become scaly and inflamed), and contact dermatitis (caused by direct skin contact with an irritating substance, such as a metal, ... How Do I Get Rid of Eczema Scars? Eczema Impetigo View more About Us Contact Us Partners Editorial Policy Permissions Guidelines Privacy Policy & ...

  13. Multi-stage flash degaser

    DOEpatents

    Rapier, P.M.

    1980-06-26

    A multi-stage flash degaser is incorporated in an energy conversion system having a direct-contact, binary-fluid heat exchanger to remove essentially all of the noncondensable gases from geothermal brine ahead of the direct-contact binary-fluid heat exchanger in order that the heat exchanger and a turbine and condenser of the system can operate at optimal efficiency.

  14. Industrial applications of the air direct-contact, gravel, ground heat exchanger

    NASA Astrophysics Data System (ADS)

    Cepiński, Wojciech; Besler, Maciej

    2017-11-01

    The paper describes the analysis of possibility of using the air direct-contact, gravel, ground heat exchanger (Polish acronym BGWCiM), patented at the Wroclaw University of Science and Technology to prepare air for conditioning rooms in the industry. Indicated the industry sectors where the application may be the most beneficial.

  15. Validation of radiocarpal joint contact models based on images from a clinical MRI scanner.

    PubMed

    Johnson, Joshua E; McIff, Terence E; Lee, Phil; Toby, E Bruce; Fischer, Kenneth J

    2014-01-01

    This study was undertaken to assess magnetic resonance imaging (MRI)-based radiocarpal surface contact models of functional loading in a clinical MRI scanner for future in vivo studies, by comparison with experimental measures from three cadaver forearm specimens. Experimental data were acquired using a Tekscan sensor during simulated light grasp. Magnetic resonance (MR) images were used to obtain model geometry and kinematics (image registration). Peak contact pressures (PPs) and average contact pressures (APs), contact forces and contact areas were determined in the radiolunate and radioscaphoid joints. Contact area was also measured directly from MR images acquired with load and compared with model data. Based on the validation criteria (within 25% of experimental data), out of the six articulations (three specimens with two articulations each), two met the criterion for AP (0%, 14%); one for peak pressure (20%); one for contact force (5%); four for contact area with respect to experiment (8%, 13%, 19% and 23%), and three contact areas met the criterion with respect to direct measurements (14%, 21% and 21%). Absolute differences between model and experimental PPs were reasonably low (within 2.5 MPa). Overall, the results indicate that MRI-based models generated from 3T clinical MR scanner appear sufficient to obtain clinically relevant data.

  16. 78 FR 63408 - Petition To Amend Animal Welfare Act Regulations To Prohibit Public Contact With Big Cats, Bears...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-10-24

    ... Regulations To Prohibit Public Contact With Big Cats, Bears, and Nonhuman Primates AGENCY: Animal and Plant... into direct or physical contact with big cats, bears, or nonhuman primates of any age, to define the... coming. FOR FURTHER INFORMATION CONTACT: Dr. Barbara Kohn, DVM, Senior Staff Officer, USDA, APHIS, Animal...

  17. Comparison of various contact algorithms for poroelastic tissues.

    PubMed

    Galbusera, Fabio; Bashkuev, Maxim; Wilke, Hans-Joachim; Shirazi-Adl, Aboulfazl; Schmidt, Hendrik

    2014-01-01

    Capabilities of the commercial finite element package ABAQUS in simulating frictionless contact between two saturated porous structures were evaluated and compared with those of an open source code, FEBio. In ABAQUS, both the default contact implementation and another algorithm based on an iterative approach requiring script programming were considered. Test simulations included a patch test of two cylindrical slabs in a gapless contact and confined compression conditions; a confined compression test of a porous cylindrical slab with a spherical porous indenter; and finally two unconfined compression tests of soft tissues mimicking diarthrodial joints. The patch test showed almost identical results for all algorithms. On the contrary, the confined and unconfined compression tests demonstrated large differences related to distinct physical and boundary conditions considered in each of the three contact algorithms investigated in this study. In general, contact with non-uniform gaps between fluid-filled porous structures could be effectively simulated with either ABAQUS or FEBio. The user should be aware of the parameter definitions, assumptions and limitations in each case, and take into consideration the physics and boundary conditions of the problem of interest when searching for the most appropriate model.

  18. Particle trap to sheath contact for a gas-insulated transmission line having a corrugated outer conductor

    DOEpatents

    Fischer, William H.; Cookson, Alan H.; Yoon, Kue H.

    1984-04-10

    A particle trap to outer elongated conductor or sheath contact for gas-insulated transmission lines. The particle trap to outer sheath contact of the invention is applicable to gas-insulated transmission lines having either corrugated or non-corrugated outer sheaths. The contact of the invention includes an electrical contact disposed on a lever arm which in turn is rotatably disposed on the particle trap and biased in a direction to maintain contact between the electrical contact and the outer sheath.

  19. Analysis of rolling contact spall life in 440 C steel bearing rims

    NASA Technical Reports Server (NTRS)

    Bastias, P. C.; Bhargava, V.; Bower, A. P.; Du, J.; Gupta, V.; Hahn, G. T.; Kulkarni, S. M.; Kumar, A. M.; Leng, X.; Rubin, C. A.

    1991-01-01

    The results of a two year study of the mechanisms of spall failure in the HPOTP bearings are described. The objective was to build a foundation for detailed analyses of the contact life in terms of: cyclic plasticity, contact mechanics, spall nucleation, and spall growth. Since the laboratory rolling contact testing is carried out in the 3 ball/rod contact fatigue testing machine, the analysis of the contacts and contact lives produced in this machine received attention. The results from the experimentally observed growth lives are compared with calculated predictions derived from the fracture mechanics calculations.

  20. Biocompatibility tests of components of an implantable cardiac assist device.

    PubMed

    von Recum, A F; Imamura, H; Freed, P S; Kantrowitz, A; Chen, S T; Ekstrom, M E; Baechler, C A; Barnhart, M I

    1978-09-01

    A permanently implantable in-series left ventricular assist device, the dynamic aortic patch (DAP), has been tested in chronic animal experiments. The DAP replaces a section of the intrathoracic aortic wall. Hemothorax and hematocele at the implantation site have been complications in recent experiments. Primary postoperative hemorrhage was ruled out, and the biocompatibility of all components was therefore examined. Dacron velour, Teflon felt, conductive polyurethane, segmented polyether polyurethane, and Teflon-coated polyester fiber sutures were implanted in the pleural cavities of dogs and tested in vitro by culturing canine saphenous vein explants on them. In vivo experiments demonstrated that all components elicited mild to moderate inflammatory reactions, but hematocele occurred only when the components were implanted in the aorta with direct blood contact and exposed to arterial blood pressures. In vitro, cells were cultured on all components with no signs of toxic reactions. These results indicated that the host tolerated all implant components without major inflammatory responses. However, histological data indicated that chronic slow bleeding into or through the Dacron velour in contact with the arterial blood serum could account for hemothorax or hematocele formation. Therefore, a configuration of the assist device using materials impermeable to blood may obviate these difficulties.

  1. Cosmetics and herbal remedies with Compositae plant extracts - are they tolerated by Compositae-allergic patients?

    PubMed

    Paulsen, Evy; Chistensen, Lars P; Andersen, Klaus E

    2008-01-01

    Compositae-sensitive patients are routinely warned against topical use of Compositae-containing cosmetics and herbal remedies. However, the risk of elicitation of dermatitis in presensitized persons is unknown. The main aim of this study was to assess the significance of direct plant allergen contact via Compositae-derived cosmetics and herbal remedies in Compositae-allergic patients with special reference to arnica (Arnica montana) and German chamomile (Chamomilla recutita). 8 of 12 chamomile-sensitive patients tested positive to chamomile-containing preparations, including tea, creams, ointments, and oil. 5 of 6 arnica-sensitive persons tested positive to arnica-based products. When the group was patch tested with cosmetic and/or herbal product ingredients, plant allergens elicited positive reactions most frequently, but fragrances, emulsifiers, and preservatives tested positive as well. Plant allergens were mainly derived from Compositae, but avocado oil, and Hamamelis virginiana tincture were unexpectedly detected as sensitizers too. Chemical analyses indicated that the Compositae allergens were both sesquiterpene lactones and other naturally occurring compounds. In conclusion, Compositae-allergic persons should be warned against topical use of Compositae-containing products, not only because of the plant allergens, but also because of allergenic cream constituents that may cause reactions in the group of patients who have multiple contact allergies beside the Compositae allergy.

  2. A profilometry-based dentifrice abrasion Method for V8 brushing machines. Part I: Introduction to RDA-PE.

    PubMed

    White, Donald J; Schneiderman, Eva; Colón, Ellen; St John, Samuel

    2015-01-01

    This paper describes the development and standardization of a profilometry-based method for assessment of dentifrice abrasivity called Radioactive Dentin Abrasivity - Profilometry Equivalent (RDA-PE). Human dentine substrates are mounted in acrylic blocks of precise standardized dimensions, permitting mounting and brushing in V8 brushing machines. Dentin blocks are masked to create an area of "contact brushing." Brushing is carried out in V8 brushing machines and dentifrices are tested as slurries. An abrasive standard is prepared by diluting the ISO 11609 abrasivity reference calcium pyrophosphate abrasive into carboxymethyl cellulose/glycerin, just as in the RDA method. Following brushing, masked areas are removed and profilometric analysis is carried out on treated specimens. Assessments of average abrasion depth (contact or optical profilometry) are made. Inclusion of standard calcium pyrophosphate abrasive permits a direct RDA equivalent assessment of abrasion, which is characterized with profilometry as Depth test/Depth control x 100. Within the test, the maximum abrasivity standard of 250 can be created in situ simply by including a treatment group of standard abrasive with 2.5x number of brushing strokes. RDA-PE is enabled in large part by the availability of easy-to-use and well-standardized modern profilometers, but its use in V8 brushing machines is enabled by the unique specific conditions described herein. RDA-PE permits the evaluation of dentifrice abrasivity to dentin without the requirement of irradiated teeth and infrastructure for handling them. In direct comparisons, the RDA-PE method provides dentifrice abrasivity assessments comparable to the gold industry standard RDA technique.

  3. Spiral Orbit Tribometer

    NASA Technical Reports Server (NTRS)

    Pepper, Stephen V.; Jones, William R., Jr.; Kingsbury, Edward; Jansen, Mark J.

    2007-01-01

    The spiral orbit tribometer (SOT) bridges the gap between full-scale life testing and typically unrealistic accelerated life testing of ball-bearing lubricants in conjunction with bearing ball and race materials. The SOT operates under realistic conditions and quickly produces results, thereby providing information that can guide the selection of lubricant, ball, and race materials early in a design process. The SOT is based upon a simplified, retainerless thrust bearing comprising one ball between flat races (see figure). The SOT measures lubricant consumption and degradation rates and friction coefficients in boundary lubricated rolling and pivoting contacts. The ball is pressed between the lower and upper races with a controlled force and the lower plate is rotated. The combination of load and rotation causes the ball to move in a nearly circular orbit that is, more precisely, an opening spiral. The spiral s pitch is directly related to the friction coefficient. At the end of the orbit, the ball contacts the guide plate, restoring the orbit to its original radius. The orbit is repeatable throughout the entire test. A force transducer, mounted in-line with the guide plate, measures the force between the ball and the guide plate, which directly relates to the friction coefficient. The SOT, shown in the figure, can operate in under ultra-high vacuum (10(exp -9) Torr) or in a variety of gases at atmospheric pressure. The load force can be adjusted between 45 and 450 N. By varying the load force and ball diameter, mean Hertzian stresses between 0.5 and 5.0 GPa can be obtained. The ball s orbital speed range is between 1 and 100 rpm.

  4. Laboratory study of PCB transport from primary sources to settled dust.

    PubMed

    Liu, Xiaoyu; Guo, Zhishi; Krebs, Kenneth A; Greenwell, Dale J; Roache, Nancy F; Stinson, Rayford A; Nardin, Joshua A; Pope, Robert H

    2016-04-01

    Dust is an important sink for indoor air pollutants, such as polychlorinated biphenyls (PCBs) that were used in building materials and products. In this study, two types of dust, house dust and Arizona Test Dust, were tested in a 30-m(3) stainless steel chamber with two types of panels. The PCB-containing panels were aluminum sheets coated with a PCB-spiked primer or caulk. The PCB-free panels were coated with the same materials but without PCBs. The dust evenly spread on each panel was collected at different times to determine its PCB content. The data from the PCB panels were used to evaluate the PCB migration from the source to the dust through direct contact, and the data from the PCB-free panels were used to evaluate the sorption of PCBs through the dust/air partition. Settled dust can adsorb PCBs from air. The sorption concentration was dependent on the congener concentration in the air and favored less volatile congeners. When the house dust was in direct contact with the PCB-containing panel, PCBs migrated into the dust at a much faster rate than the PCB transfer rate due to the dust/air partition. The dust/source partition was not significantly affected by the congener's volatility. For a given congener, the ratio between its concentration in the dust and in the source was used to estimate the dust/source partition coefficient. The estimated values ranged from 0.04 to 0.16. These values are indicative of the sink strength of the tested house dust being in the middle or lower-middle range. Published by Elsevier Ltd.

  5. Contact problem for an elastic reinforcement bonded to an elastic plate

    NASA Technical Reports Server (NTRS)

    Erdogan, F.; Civelek, M. B.

    1973-01-01

    The stiffening layer is treated as an elastic membrane and the base plate is assumed to be an elastic continuum. The bonding between the two materials is assumed to be either one of direct adhesion ro through a thin adhesive layer which is treated as a shear spring. The solution for the simple case in which both the stiffener and the base plate are treated as membranes is also given. The contact stress is obtained for a series of numerical examples. In the direct adhesion case the contact stress becomes infinite at the stiffener ends with a typical square root singularity for the continuum model, and behaving as a delta function for the membrane model. In the case of bonding through an adhesive layer the contact stress becomes finite and continuous along the entire contact area.

  6. Advances in contact algorithms and their application to tires

    NASA Technical Reports Server (NTRS)

    Noor, Ahmed K.; Tanner, John A.

    1988-01-01

    Currently used techniques for tire contact analysis are reviewed. Discussion focuses on the different techniques used in modeling frictional forces and the treatment of contact conditions. A status report is presented on a new computational strategy for the modeling and analysis of tires, including the solution of the contact problem. The key elements of the proposed strategy are: (1) use of semianalytic mixed finite elements in which the shell variables are represented by Fourier series in the circumferential direction and piecewise polynomials in the meridional direction; (2) use of perturbed Lagrangian formulation for the determination of the contact area and pressure; and (3) application of multilevel iterative procedures and reduction techniques to generate the response of the tire. Numerical results are presented to demonstrate the effectiveness of a proposed procedure for generating the tire response associated with different Fourier harmonics.

  7. Occupational allergic contact dermatitis and patch test results of leather workers at two Indonesian tanneries.

    PubMed

    Febriana, Sri Awalia; Jungbauer, Frank; Soebono, Hardyanto; Coenraads, Pieter-Jan

    2012-11-01

    Tannery workers are at considerable risk of developing occupational contact dermatitis. Occupational skin diseases in tannery workers in newly industrialized countries have been reported, but neither the prevalence of occupational allergic contact dermatitis nor the skin-sensitizing agents were specifically examined in those studies. To assess the prevalence of occupational allergic contact dermatitis in Indonesian tanneries, identify the causative allergens, and propose a tannery work series of patch test allergens. A cross-sectional study in all workers at two Indonesian tanneries was performed to assess the prevalence of occupational contact dermatitis via a questionnaire-based interview and skin examination. Workers with occupational contact dermatitis were patch tested to identify the causative allergens. Occupational contact dermatitis was suspected in 77 (16%) of the 472 workers. Thirteen (3%) of these 472 workers were confirmed to have occupational allergic contact dermatitis. Potassium dichromate (9.2%), N,N-diphenylguanidine (5.3%), benzidine (3.9%) and sodium metabisulfite (2.6%) were found to be the occupationally relevant sensitizers. The sensitization pattern showed some differences from the data in studies reported from other newly industrial countries. We compiled a 'tannery work series' of allergens for patch testing. A number of these allergens may also be considered for patch testing in patients with (leather) shoe dermatitis. © 2012 John Wiley & Sons A/S.

  8. Tibiofemoral forces for the native and post-arthroplasty knee: relationship to maximal laxity through a functional arc of motion.

    PubMed

    Manning, William A; Ghosh, Kanishka; Blain, Alasdair; Longstaff, Lee; Deehan, David John

    2017-06-01

    Accurate soft tissue balance must be achieved to improve functional outcome after total knee arthroplasty (TKA). Sensor-integrated tibial trials have been introduced that allow real-time measurement of tibiofemoral kinematics during TKA. This study examined the interplay between tibiofemoral force and laxity, under defined intraoperative conditions, so as to quantify the kinematic behaviour of the CR femoral single-radius knee. TKA was undertaken in eight loaded cadaveric specimens. Computer navigation in combination with sensor data defined laxity and tibiofemoral contact force, respectively, during manual laxity testing. Fixed-effect linear modelling allowed quantification of the effect for flexion angle, direction of movement and TKA implantation upon the knee. An inverse relationship between laxity and contact force was demonstrated. With flexion, laxity increased as contact force decreased under manual stress. Change in laxity was significant beyond 30° for coronal plane laxity and beyond 60° for rotatory laxity (p < 0.01). Rotational stress in mid-flexion demonstrated the greatest mismatch in inter-compartmental forces. Contact point position over the tibial sensor demonstrated paradoxical roll-forward with knee flexion. Traditional balancing techniques may not reliably equate to uniform laxity or contact forces across the tibiofemoral joint through a range of flexion and argue for the role of per-operative sensor use to aid final balancing of the knee.

  9. Clamshell closure for metal drum

    DOEpatents

    Blanton, Paul S

    2014-09-30

    Closure ring to retain a lid in contact with a metal drum in central C-section conforming to the contact area between a lid and the rim of a drum and further having a radially inwardly directed flange and a vertically downwardly directed flange attached to the opposite ends of the C-section. The additional flanges reinforce the top of the drum by reducing deformation when the drum is dropped and maintain the lid in contact with the drum. The invention is particularly valuable in transportation and storage of fissile material.

  10. A general design strategy for block copolymer directed self-assembly patterning of integrated circuits contact holes using an alphabet approach.

    PubMed

    Yi, He; Bao, Xin-Yu; Tiberio, Richard; Wong, H-S Philip

    2015-02-11

    Directed self-assembly (DSA) is a promising lithography candidate for technology nodes beyond 14 nm. Researchers have shown contact hole patterning for random logic circuits using DSA with small physical templates. This paper introduces an alphabet approach that uses a minimal set of small physical templates to pattern all contacts configurations on integrated circuits. We illustrate, through experiments, a general and scalable template design strategy that links the DSA material properties to the technology node requirements.

  11. The contactless detection of local normal transitions in superconducting coils by using Poynting’s vector method

    NASA Astrophysics Data System (ADS)

    Habu, K.; Kaminohara, S.; Kimoto, T.; Kawagoe, A.; Sumiyoshi, F.; Okamoto, H.

    2010-11-01

    We have developed a new monitoring system to detect an unusual event in the superconducting coils without direct contact on the coils, using Poynting's vector method. In this system, the potential leads and pickup coils are set around the superconducting coils to measure local electric and magnetic fields, respectively. By measuring the sets of magnetic and electric fields, the Poynting's vectors around the coil can be obtained. An unusual event in the coil can be detected as the result of the change of the Poynting's vector. This system has no risk of the voltage breakdown which may happen with the balance voltage method, because there is no need of direct contacts on the coil windings. In a previous paper, we have demonstrated that our system can detect the normal transitions in the Bi-2223 coil without direct contact on the coil windings by using a small test system. For our system to be applied to practical devices, it is necessary for the early detection of an unusual event in the coils to be able to detect local normal transitions in the coils. The signal voltages of the small sensors to measure local magnetic and electric fields are small. Although the increase in signals of the pickup coils is attained easily by an increase in the number of turns of the pickup coils, an increase in the signals of the potential lead is not easily attained. In this paper, a new method to amplify the signal of local electric fields around the coil is proposed. The validity of the method has been confirmed by measuring local electric fields around the Bi-2223 coil.

  12. Nickel release from surgical instruments and operating room equipment.

    PubMed

    Boyd, Anne H; Hylwa, Sara A

    2018-04-15

    Background There has been no systematic study assessing nickel release from surgical instruments and equipment used within the operating suite. This equipment represents important potential sources of exposure for nickel-sensitive patients and hospital staff. To investigate nickel release from commonly used surgical instruments and operating room equipment. Using the dimethylglyoxime nickel spot test, a variety of surgical instruments and operating room equipment were tested for nickel release at our institution. Of the 128 surgical instruments tested, only 1 was positive for nickel release. Of the 43 operating room items tested, 19 were positive for nickel release, 7 of which have the potential for direct contact with patients and/or hospital staff. Hospital systems should be aware of surgical instruments and operating room equipment as potential sources of nickel exposure.

  13. Adiabatic demagnetization refrigerator for space use

    NASA Technical Reports Server (NTRS)

    Serlemitsos, A. T.; Warner, B. A.; Castles, S.; Breon, S. R.; San Sebastian, M.; Hait, T.

    1990-01-01

    An Adiabatic Demagnetization Refrigerator (ADR) for space use is under development at NASA's Goddard Space Flight Center (GSFC). The breadboard ADR operated at 100 mK for 400 minutes. Some significant changes to that ADR, designed to eliminate shortcomings revealed during tests, are reported. To increase thermal contact, the ferric ammonium sulfate crystals were grown directly on gold-plated copper wires which serve as the thermal bus. The thermal link to the X-ray sensors was also markedly improved. To speed up the testing required to determine the best design parameters for the gas gap heat switch, the new heat switch has a modular design and is easy to disassemble.

  14. Estimation of masonry mechanical characteristics by ESPI fringe interpretation

    NASA Astrophysics Data System (ADS)

    Facchini, M.; Zanetta, P.; Binda, L.; Roberti, G. Mirabella; Tiraboschi, C.

    Electronic speckle pattern interferometry (ESPI) can be a powerful tool for efficient non-destructive testing and evaluation of micro-deformations of masonry materials and structures. Unlike traditional transducers, ESPI requires no direct contact with the object, and the full-field visualisation it offers provides for a better understanding of the surface behaviour. This paper describes an in-plane deformation inspection system which has been built up for an automatic acquisition of interferograms at different stages of a test. The system is applied to the evaluation of some mechanical characteristics of masonry components. Qualitative and quantitative results are obtained and an overall discussion is presented.

  15. Adiabatic demagnetization refrigerator for space use

    NASA Astrophysics Data System (ADS)

    Serlemitsos, A. T.; Warner, B. A.; Castles, S.; Breon, S. R.; San Sebastian, M.; Hait, T.

    An Adiabatic Demagnetization Refrigerator (ADR) for space use is under development at NASA's Goddard Space Flight Center (GSFC). The breadboard ADR operated at 100 mK for 400 minutes. Some significant changes to that ADR, designed to eliminate shortcomings revealed during tests, are reported. To increase thermal contact, the ferric ammonium sulfate crystals were grown directly on gold-plated copper wires which serve as the thermal bus. The thermal link to the X-ray sensors was also markedly improved. To speed up the testing required to determine the best design parameters for the gas gap heat switch, the new heat switch has a modular design and is easy to disassemble.

  16. The development of a non-cryogenic nitrogen/oxygen supply system

    NASA Technical Reports Server (NTRS)

    Greenough, B. M.

    1972-01-01

    Development of the hydrazine/water electrolysis process in a manned spacecraft to provide metabolic oxygen and both oxygen and nitrogen for cabin leakage makeup was studied. Electrode development efforts were directed to stability, achieved with catalyst additives and improved processing techniques, and a higher hydrazine conversion efficiency, achieved by reducing catalyst loading on the cathodes. Extensive testing of the one-man breadboard N2/02 system provided complete characterization of cabin atmosphere control aspects. A detailed design of a prototype modular N2/02 unit was conducted. The contact heat exchanger which is an integral component of this design was fabricated and sucessfully design-verification tested.

  17. In-vitro analysis of the microbicidal activity of 6 contact lens care solutions

    PubMed Central

    2012-01-01

    Background Contact lens-related infections are often associated with inadequate contact lens hygiene, and therefore, contact lens care products should be able to sufficiently minimise the amount of pathogens that are responsible for these infections. In 2001, the EN ISO 14729 was introduced to ensure adequate disinfection efficacy of contact lens care solutions, but this norm has recently been criticised. Methods In this study, six frequently used contact lens care solutions were retested according to the Stand Alone Test of the EN ISO 14729 (2001). The Stand Alone Test is a quantitative suspension test. In addition, the products were tested in a modified setting adding an organic load. The load was a mixture of human blood serum, lysozyme, and mucine, which resembles tear fluid. Results The criteria of the Stand Alone Test recommended in EN ISO 14729 were only met by Aosept Plus. This 3% hydrogen-peroxide-based contact lens care solution attained a reduction factor of > 5 log units for bacteria and > 4 for fungi in all cases. Two further contact lens care solutions, Blue Vision and Optifree Replenish, met the criteria of a reduction factor of > 3 log units for bacteria and > 1 log unit for fungi, but only in the presence of artificial tear fluid. The three remaining products did not exhibit adequate disinfecting efficacy, at least against one of the tested microorganisms. Conclusions Through the observation that the artificial tear fluid used in this study influences the disinfecting efficacy of contact lens care solutions, especially that of multi-purpose solutions, in a different way than does albumin, mucine, or even the organic load suggested in EN ISO 14729, it becomes obvious that the test conditions in the EN ISO 14729 should be revised in order to create more realistic conditions, e.g., by using a more realistic artificial tear fluid. Furthermore, we suggest adapting the EN ISO 14729 to the European test hierarchy for chemical disinfectants and antiseptics, which consists of three test phases and also requests meeting stricter criteria in order to pass the test. Unless the test conditions guarantee a sufficient reduction of potential pathogens, the risk of contact lens-related microbial keratitis and other infections will remain for the users. PMID:23033880

  18. Ferromagnetic tunnel contacts to graphene: Contact resistance and spin signal

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cubukcu, M.; Laczkowski, P.; Vergnaud, C.

    2015-02-28

    We report spin transport in CVD graphene-based lateral spin valves using different magnetic contacts. We compared the spin signal amplitude measured on devices where the cobalt layer is directly in contact with the graphene to the one obtained using tunnel contacts. Although a sizeable spin signal (up to ∼2 Ω) is obtained with direct contacts, the signal is strongly enhanced (∼400 Ω) by inserting a tunnel barrier. In addition, we studied the resistance-area product (R.A) of a variety of contacts on CVD graphene. In particular, we compared the R.A products of alumina and magnesium oxide tunnel barriers grown by sputteringmore » deposition of aluminum or magnesium and subsequent natural oxidation under pure oxygen atmosphere or by plasma. When using an alumina tunnel barrier on CVD graphene, the R.A product is high and exhibits a large dispersion. This dispersion can be highly reduced by using a magnesium oxide tunnel barrier, as for the R.A value. This study gives insight in the material quest for reproducible and efficient spin injection in CVD graphene.« less

  19. The effect of benzalkonium chloride additions to AH Plus sealer. Antimicrobial, physical and chemical properties.

    PubMed

    Arias-Moliz, M T; Ruiz-Linares, M; Cassar, G; Ferrer-Luque, C M; Baca, P; Ordinola-Zapata, R; Camilleri, J

    2015-07-01

    The aim of this study was to determine the antimicrobial and antibiofilm activities and physicochemical properties of AH Plus sealer mixed with different concentrations of benzalkonium chloride (BC). AH Plus was tested alone and mixed with 1%, 2% and 3% of BC. The antimicrobial and antibiofilm activities of the sealers against Enterococcus faecalis were evaluated by the direct contact test (DCT) and by confocal laser scanning microscopy, respectively. Setting time, flow and solubility were assessed according to ANSI/ADA specifications. Microhardness and contact angle tests were also performed. The chemical changes of the sealers were evaluated by X-ray diffraction analysis, and both Fourier transform infrared spectroscopy (FT-IR) and attenuated total reflectance Fourier transform infrared (ATR FT-IR). AH Plus+3% BC was the only sealer to promote total elimination of E. faecalis and the biovolume in this group was significantly lower than in the rest of the sealers (p>0.05). The physical properties of the sealers were according to the ANSI/ADA specifications. The microhardness decreased significantly when BC was added and a significant reduction in contact angle was obtained when incorporating 2% and 3% BC (p<0.05). No phase changes were observed with the modified sealers. The addition of 2% or higher concentrations BC to AH Plus showed antimicrobial and antibiofilm activities without affecting the properties specified in ANSI/ADA standards. However, additives to the root canal sealer altered other physical and chemical properties that are not commonly found in the literature to evaluate filling materials. The present study highlights that the antimicrobial properties of AH Plus can be significantly improved with the addition of BC. Testing beyond what is specified in standards may be indicated. Copyright © 2015 Elsevier Ltd. All rights reserved.

  20. Liquid-Feed Methanol Fuel Cell With Membrane Electrolyte

    NASA Technical Reports Server (NTRS)

    Surampudi, Subbarao; Narayanan, S. R.; Halpert, Gerald; Frank, Harvey; Vamos, Eugene

    1995-01-01

    Fuel cell generates electricity from direct liquid feed stream of methanol/water solution circulated in contact with anode, plus direct gaseous feed stream of air or oxygen in contact with cathode. Advantages include relative simplicity and elimination of corrosive electrolytic solutions. Offers potential for reductions in size, weight, and complexity, and for increases in safety of fuel-cell systems.

  1. 49 CFR 393.136 - What are the rules for securing large boulders?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-separated points of contact that prevent its tendency to roll in any direction. (5) If a boulder is tapered...) Only chain may be used as tiedowns to secure large boulders. (2) Tiedowns which are in direct contact... boulder. Whenever practicable, the angle of the chains must not exceed 45 degrees from the horizontal. ...

  2. Post-Adoption Face-to-Face Contact with Birth Parents: Prospective Adopters' Views

    ERIC Educational Resources Information Center

    Turkington, Selina; Taylor, Brian J.

    2009-01-01

    The trend in adoption since the 1960s has been away from secrecy and towards greater openness; contact through an intermediary, and direct contact by letter, is now widely accepted. More controversial is the challenge of face-to-face contact with birth parents, and social workers involved in the decision-making process find themselves having to…

  3. In situ electronic probing of semiconducting nanowires in an electron microscope.

    PubMed

    Fauske, V T; Erlbeck, M B; Huh, J; Kim, D C; Munshi, A M; Dheeraj, D L; Weman, H; Fimland, B O; Van Helvoort, A T J

    2016-05-01

    For the development of electronic nanoscale structures, feedback on its electronic properties is crucial, but challenging. Here, we present a comparison of various in situ methods for electronically probing single, p-doped GaAs nanowires inside a scanning electron microscope. The methods used include (i) directly probing individual as-grown nanowires with a sharp nano-manipulator, (ii) contacting dispersed nanowires with two metal contacts and (iii) contacting dispersed nanowires with four metal contacts. For the last two cases, we compare the results obtained using conventional ex situ litho-graphy contacting techniques and by in situ, direct-write electron beam induced deposition of a metal (Pt). The comparison shows that 2-probe measurements gives consistent results also with contacts made by electron beam induced deposition, but that for 4-probe, stray deposition can be a problem for shorter nanowires. This comparative study demonstrates that the preferred in situ method depends on the required throughput and reliability. © 2015 The Authors Journal of Microscopy © 2015 Royal Microscopical Society.

  4. Dynamic Contact Angle at the Nanoscale: A Unified View.

    PubMed

    Lukyanov, Alex V; Likhtman, Alexei E

    2016-06-28

    Generation of a dynamic contact angle in the course of wetting is a fundamental phenomenon of nature. Dynamic wetting processes have a direct impact on flows at the nanoscale, and therefore, understanding them is exceptionally important to emerging technologies. Here, we reveal the microscopic mechanism of dynamic contact angle generation. It has been demonstrated using large-scale molecular dynamics simulations of bead-spring model fluids that the main cause of local contact angle variations is the distribution of microscopic force acting at the contact line region. We were able to retrieve this elusive force with high accuracy. It has been directly established that the force distribution can be solely predicted on the basis of a general friction law for liquid flow at solid surfaces by Thompson and Troian. The relationship with the friction law provides both an explanation of the phenomenon of dynamic contact angle and a methodology for future predictions. The mechanism is intrinsically microscopic, universal, and irreducible and is applicable to a wide range of problems associated with wetting phenomena.

  5. Direct measurement of friction of a fluctuating contact line

    NASA Astrophysics Data System (ADS)

    Guo, Shuo; Gao, Min; Xiong, Xiaomin; Wang, Yong Jian; Wang, Xiaoping; Sheng, Ping; Tong, Penger

    2013-03-01

    What happens at a moving contact line, where one fluid displaces another (immiscible) fluid over a solid surface, is a fundamental issue in fluid dynamics. In this presentation, we report a direct measurement of the friction coefficient in the immediate vicinity of a fluctuating contact line using a micron-sized vertical glass fiber with one end glued to an atomic force microscope (AFM) cantilever beam and the other end touching a liquid-air interface. By measuring the broadening of the resonance peak of the cantilever system with varying liquid viscosity η, we obtain the friction coefficient ξc associated with the contact line fluctuations on the glass fiber of diameter d and find it has the universal form, ξc = 0 . 8 πdη , independent of the contact angle. The result is further confirmed by using a soap film system whose bulk effect is negligibly small. This is the first time that the friction coefficient of a fluctuating contact line is measured. *Work supported by the Research Grants Council of Hong Kong SAR.

  6. T cell lymphomatoid contact dermatitis: a challenging case and review of the literature.

    PubMed

    Knackstedt, Thomas J; Zug, Kathryn A

    2015-02-01

    Lymphomatoid contact dermatitis is a pseudolymphoma with clinical and histological features of allergic contact dermatitis and cutaneous T cell lymphoma. Incorrect diagnosis may lead to unnecessary testing, unnecessary treatment, or patient harm. The objective of this study is to present a case to demonstrate the diagnostic challenge and overlap between allergic contact dermatitis and cutaneous T cell lymphoma in a patient with lymphomatoid contact dermatitis caused by methylchoroisothiazolinone/methylisothiazolinone and paraben mix, and to review the existing literature in order to summarize the demographics, clinical features, allergens and treatments reported for lymphomatoid contact dermatitis. A search of major scientific databases was conducted for English-language articles reporting cases of lymphomatoid contact dermatitis or additional synonymous search headings. Nineteen articles with a total of 23 patients were analysed. Lymphomatoid contact dermatitis was more common in men, with an average age of 58.5 years. Fourteen unique allergens were identified and confirmed by patch testing. However, no single test or study was diagnostic of lymphomatoid contact dermatitis. Allergen avoidance was the most useful management tool, but selected patients required topical or systemic immunosuppression. In conclusion, without specific diagnostic features, evaluation for lymphomatoid contact dermatitis should include a thorough history and examination, patch testing, and biopsy with immunohistochemistry and clonality studies. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. Auditing the use and assessing the clinical utility of microscopy as a point-of-care test for Neisseria gonorrhoeae in a Sexual Health clinic.

    PubMed

    Mensforth, Sarah; Thorley, Nicola; Radcliffe, Keith

    2018-02-01

    We assessed whether urethral microscopy was performed as per clinic protocol for male clinic attendees reporting contact with Neisseria gonorrhoeae (GC), urethral symptoms or given a diagnosis of epididymo-orchitis (EO) over a 12-month period (9732 patients). Prevalence of gonorrhoea in the contacts, urethral symptoms and EO groups was 50, 12.7 and 1.6%, respectively. Microscopy was performed reliably for contacts (96%), those with discharge/dysuria with evidence of urethritis on examination (98%), but not those with EO (43%). We explored the clinical utility of microscopy as a point-of-care test for identifying urethral GC in each subgroup, using the APTIMA Combo 2 CT/GC nucleic acid amplification test as the comparator (1710 patients). Sensitivity of microscopy for each subgroup was good; there was no statistical difference between subgroup sensitivity using Fisher's exact test. Microscopy is valuable to ensure prompt diagnosis and contact tracing. All GC contacts were treated 'epidemiologically'; however, half of GC contacts did not have GC. Microscopy identified the majority of GC cases, including amongst contacts (71% of heterosexual contacts, 66% of contacts reporting sex with men). We propose that epidemiological treatment for GC contacts should be reconsidered on the grounds of antibiotic stewardship, favouring use of microscopy to guide treatment decisions.

  8. Inhibitory effect of sodium hypochlorite and chlorhexidine digluconate in clinical isolates of Sporothrix schenckii.

    PubMed

    Madrid, Isabel Martins; Mattei, Antonella Souza; Santin, Rosema; dos Reis Gomes, Angelita; Cleff, Marlete Brum; Meireles, Mário Carlos Araújo

    2012-05-01

    The susceptibility of Sporothrix schenckii isolates from clinical cases of canine, feline and human sporotrichosis, and from the environment, was evaluated with 4% sodium hypochlorite and 6.6% chlorhexidine digluconate using the broth microdilution, agar diffusion and direct exposure techniques. The minimal inhibitory concentration was smaller than 0.8% for chlorhexidine digluconate and between 8% and 4% for sodium hypochlorite. Inhibition zones were not found in agar diffusion for sodium hypochlorite, and zones averaging 1.9 mm were found for chlorhexidine digluconate. In the direct exposure test, sodium hypochlorite demonstrated best performance at 20 min of contact, as chlorhexidine digluconate presented little antimicrobial activity. © 2011 Blackwell Verlag GmbH.

  9. Multicenter Patch Testing With Methylisothiazolinone and Methylchloroisothiazolinone/Methylisothiazolinone Within the International Contact Dermatitis Research Group.

    PubMed

    Isaksson, Marléne; Ale, Iris; Andersen, Klaus E; Elsner, Peter; Goh, Chee-Leok; Goossens, An; Jerajani, Hemangi; Matsunaga, Kayoko; McFadden, John; Bruze, Magnus

    The preservatives methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) and MI are well-known contact sensitizers. Recently, an increase in the contact allergy frequency for MI 0.2% aqueous (aq) has been seen in many European countries paralleled with an increase in MCI/MI allergy. Many of the MI-allergic patients do not react to MCI/MI 0.01% or 0.02% because the concentration of MI in these preparations is too low (25 and 50 ppm, respectively) to elicit a positive patch test reaction. The aims of this study were to investigate the prevalence of contact allergy to MI in the participating clinics representing various countries all over the world, to assess how many additional individuals with contact allergy are found by testing MI 0.2% aq in parallel with MCI/MI 0.02%, and to assess the clinical relevance of MI and MCI/MI allergies. In 9 dermatology clinics representing 9 countries, 3865 consecutive patients with dermatitis were patch tested with MI 0.2% aq and in parallel with MCI/MI 0.02% aq, provisionally included into the baseline series. An assessment of clinical relevance in those allergic to MI was also made. Contact allergy to MI was found in 284 patients (7.3%). The frequency of contact allergy varied from 0.8% to 10.9% in different centers. Simultaneous reactivity to 200 ppm of MCI/MI was found in 67.3% of the MI-positive patients. Contact allergy to MI alone without any simultaneous contact allergy to 200 ppm of MCI/MI was diagnosed in 93 patients (32.7%; 2.4% of all tested patients). The contact allergy to MI and/or MCI/MI could explain or contribute to dermatitis in more than 60% of the MI-allergic patients. Methylisothiazolinone of 2000 ppm needs to be patch tested on its own to not miss contact allergy.

  10. Impact of crystal orientation on ohmic contact resistance of enhancement-mode p-GaN gate high electron mobility transistors on 200 mm silicon substrates

    NASA Astrophysics Data System (ADS)

    Van Hove, Marleen; Posthuma, Niels; Geens, Karen; Wellekens, Dirk; Li, Xiangdong; Decoutere, Stefaan

    2018-04-01

    p-GaN gate enhancement mode power transistors were processed in a Si CMOS processing line on 200 mm Si(111) substrates using Au-free metallization schemes. Si/Ti/Al/Ti/TiN ohmic contacts were formed after full recessing of the AlGaN barrier, followed by a HCl-based wet cleaning step. The electrical performance of devices aligned to the [11\\bar{2}0] and the perpendicular [1\\bar{1}00] directions was compared. The ohmic contact resistance was decreased from 1 Ω·mm for the [11\\bar{2}0] direction to 0.35 Ω·mm for the [1\\bar{1}00] direction, resulting in an increase of the drain saturation current from 0.5 to 0.6 A/mm, and a reduction of the on-resistance from 6.4 to 5.1 Ω·mm. Moreover, wafer mapping of the device characteristics over the 200 mm wafer showed a tighter statistical distribution for the [1\\bar{1}00] direction. However, by using an optimized sulfuric/ammonia peroxide (SPM/APM) cleaning step, the ohmic contact resistance could be lowered to 0.3 Ω·mm for both perpendicular directions.

  11. Time to contact and the control of manual prehension.

    PubMed

    Watson, M K; Jakobson, L S

    1997-11-01

    In the present study, a kinematic analysis was made of unconstrained, natural prehension movements directed toward an object approaching the observer on a conveyor belt at one of three constant velocities, from one of three different directions (head-on or along the fronto-parallel plane coming either from the subject's left or right). Subjects were required to grasp the object when it reached a target located 20 cm directly in front of the hand's start position. The kinematic analysis revealed that both the transport and grasp components of the movement changed in response to the experimental manipulations, but did so in a manner that guaranteed that, for objects approaching from a given direction, hand closure would begin at a constant time prior to object contact (regardless of the object's approach speed). The kinematic analysis also revealed, however, that the onset of hand closure began earlier with objects approaching from the right than from other directions -- an effect which would not be predicted if time to contact was the key variable controlling the onset of hand closure. These results, then, lend only partial support to the theory that temporal coordination between the transport and grasp components of prehension is ensured through their common dependence on time to contact information.

  12. [Allergic contact dermatitis to metals over a 20-year period in the Centre of Portugal: evaluation of the effects of the European directives].

    PubMed

    Teixeira, Vera; Coutinho, Inês; Gonçalo, Margarida

    2014-01-01

    Metals are a common cause of allergic contact dermatitis. After the introduction of the EU Nickel Directive (1994/27/CE; 2004/96/EC) and, more recently, the Cement Directive (2003/53/EC) there has been a significant decrease in sensitization to metals mainly in the Nordic countries. The applicability of these directives and their impact in the Portuguese population is unknown. A retrospective study (1992-2011) was carried out in our patch test clinic to assess the temporal trend of metal sensitization (nickel [Ni], cobalt [Co] and chromium [Cr]) along the last 20 years, particularly considering age, sex and its relation with occupational activity. Out of 5 250 consecutively patch-tested patients, 1 626 (31%) were reactive to at least one metal (26.5% to Ni; 10.0% to Co and 7.9% to Cr). Women had a higher prevalence of sensitization to Ni (34.4% vs 8.9%) whereas men were more reactive to Cr (11.5% vs 5.0%). Nickel sensitization did not decrease significantly over the years, although in recent years among women sensitized to nickel the percentage of younger patients (16-30 years-old) is significantly lower (p < 0.001). Chromium sensitization significantly decreased, particularly in men (r = -0.535), and mainly in the construction workers (r = -0.639). Chromium reactivity associated with the shoe dermatitis has remained stable. We emphasize the higher and stable percentage of nickel sensitized individuals suggesting, so far, a low impact from the EU Ni directive, although a decreasing percentage in the the younger group among Ni sensitized women may suggest a beneficial effect is becoming evident is this age group. On the contrary, the impact of the directive regarding the modification of Cr in cement seems to be effective. There is now a need to regulate chromium content in leather products, namely in shoes. The regulation of interventional measures related either to the manufacture and trade of adornments or professional use will better protect the population of allergy to metals.

  13. A comparison of stresses in molar teeth restored with inlays and direct restorations, including polymerization shrinkage of composite resin and tooth loading during mastication.

    PubMed

    Dejak, Beata; Młotkowski, Andrzej

    2015-03-01

    Polymerization shrinkage of composites is one of the main causes of leakage around dental restorations. Despite the large numbers of studies there is no consensus, what kind of teeth reconstruction--direct or indirect composite restorations are the most beneficial and the most durable. The aim was to compare equivalent stresses and contact adhesive stresses in molar teeth with class II MOD cavities, which were restored with inlays and direct restorations (taking into account polymerization shrinkage of composite resin) during simulated mastication. The study was conducted using the finite elements method with the application of contact elements. Three 3D models of first molars were created: model A was an intact tooth; model B--a tooth with a composite inlay, and model C--a tooth with a direct composite restoration. Polymerization linear shrinkage 0.7% of a direct composite restoration and resin luting cement was simulated (load 1). A computer simulation of mastication was performed (load 2). In these 2 situations, equivalent stresses according to the modified von Mises criterion (mvM) in the materials of mandibular first molar models with different restorations were calculated and compared. Contact stresses in the luting cement-tooth tissue adhesive interface around the restorations were also assessed and analyzed. Equivalent stresses in a tooth with a direct composite restoration (the entire volume of which was affected by polymerization shrinkage) were many times higher than in the tooth restored with a composite inlay (where shrinkage was present only in a thin layer of the luting cement). In dentin and enamel the stress values were 8-14 times higher, and were 13 times higher in the direct restoration than in the inlay. Likewise, contact stresses in the adhesive bond around the direct restoration were 6.5-7.7 times higher compared to an extraorally cured restoration. In the masticatory simulation, shear contact stresses in the adhesive bond around the direct composite restoration reached the highest values 32.8 MPa and significantly exceeded the shear strength of the connection between the resin luting cement and the tooth structure. Equivalent stresses in the tooth structures restored with inlays and in the restoration material itself and contact stresses at the tooth-luting cement adhesive interface are many times lower compared to teeth with direct composite restorations. Teeth with indirect restorations are potentially less susceptible to damage compared to those with direct restorations. Composite inlays also ensure a better seal compared to direct restorations. Polymerization shrinkage determines stress levels in teeth with direct restorations, while its impact on adhesion in indirectly restored teeth is insignificant. Copyright © 2014 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

  14. Prevalence and interest in the practice of scratch testing for contact urticaria: a survey of the American contact dermatitis society members.

    PubMed

    Orb, Quinn; Millsop, Jillian Wong; Harris, KaLynne; Powell, Douglas

    2014-01-01

    Contact urticaria (CU) is the development of a wheal and flare on the skin after topical exposure to a particular chemical or compound. It can be diagnosed through a variety of techniques. Many chemicals that cause a type IV allergy can also cause CU. The incidence of CU to these chemicals is unknown. The aim of this study was to evaluate the opinions of the American Contact Dermatitis Society members regarding CU and scratch testing. We distributed an electronic survey to the American Contact Dermatitis Society members regarding observed prevalence of CU, frequency of scratch testing in clinical practice, and interest in learning about scratch testing in diagnosing CU and other skin contact conditions. We distributed 508 surveys and received 133 responses. Seventeen percent reported that CU was extremely rare, 32% reported that CU was rare, and 38.9% reported that CU was infrequent. Alternatively, 10.7% believed that CU was common, and 1.5% believed that CU was extremely common. A minority, 19.1%, performed scratch testing on patients with suspected CU. Most respondents, 54.6%, were interested in learning about scratch testing. Additional education regarding scratch testing could increase comfort and use of scratch testing in clinical practice. Further studies are needed to evaluate the prevalence of CU in the general population and better guide the use of testing for dermatologic patients.

  15. Kaleri sets up Russian MBI-12 Payload in the SM

    NASA Image and Video Library

    2010-12-09

    ISS026-E-008718 (8 Dec. 2010) --- Russian cosmonaut Alexander Kaleri, Expedition 26 flight engineer, sets up the Russian MBI-12 payload for a Sonokard experiment session in the Zvezda Service Module of the International Space Station. Kaleri used a sports shirt from the Sonokard kit with a special device in the pocket for testing a new method for acquiring physiological data without using direct contact on the skin. Measurements are recorded on a data card for return to Earth.

  16. Kondratvez sets up Sonokard Experiment in the SM during Expedition 26

    NASA Image and Video Library

    2011-01-03

    ISS026-E-014250 (3 Jan. 2011) --- Russian cosmonaut Dmitry Kondratyev, Expedition 26 flight engineer, sets up the Russian MBI-12 payload for a Sonokard experiment session in the Zvezda Service Module of the International Space Station. Kondratyev used a sports shirt from the Sonokard kit with a special device in the pocket for testing a new method for acquiring physiological data without using direct contact on the skin. Measurements are recorded on a data card for return to Earth.

  17. Multifunctional Composites with Applications to Energy Performance and Efficiency

    DTIC Science & Technology

    2011-08-01

    surface for comparing the effects of processing. Parylene/ Teflon AF adhesion was measured using a modified tape test. Samples were razor cut (3-6...lines, 2 mm spacing ) at 0 and 90 degrees to the tape -pull direction. SEMicro CHT tape (synthetic rubber adhesive, 12 to 25 mm wide x 75 mm long) was...surface, a thin layer of Teflon AF (~200 nm) is spin- coated for hydrophobicity. Small drops of ionic liquids in contact with a conductive probe are

  18. Contact lens physical properties and lipid deposition in a novel characterized artificial tear solution

    PubMed Central

    Heynen, Miriam; Kay, Lise M.M.; Dominici, Claudia Yvette; Khan, Warda; Ng, Wendy W.S.; Jones, Lyndon

    2011-01-01

    Purpose To characterize various properties of a physiologically-relevant artificial tear solution (ATS) containing a range of tear film components within a complex salt solution, and to measure contact lens parameters and lipid deposition of a variety of contact lens materials after incubation in this ATS. Methods A complex ATS was developed that contains a range of salts, proteins, lipids, mucin, and other tear film constituents in tear-film relevant concentrations. This ATS was tested to confirm that its pH, osmolality, surface tension, and homogeneity are similar to human tears and remain so throughout the material incubation process, for up to 4 weeks. To confirm that silicone hydrogel and conventional hydrogel contact lens materials do not alter in physical characteristics beyond what is allowed by the International Organization for Standardization (ISO) 18369–2. The diameter, center thickness, and calculated base curve were measured for five different lens materials directly out of the blister pack, after a rinse in saline and then following a two week incubation in the modified ATS. To test the ATS and the effect of its composition on lipid deposition, two lens materials were incubated in the ATS and a modified version for several time points. Both ATS solutions contained trace amounts of carbon-14 cholesterol and phosphatidylcholine, such that deposition of these specific lipids could be quantified using standard methods. Results This ATS is a complex mixture that remains stable at physiologically relevant pH (7.3–7.6), osmolality (304–306 mmol/kg), surface tension (40–46 dynes/cm) and homogeneity over an incubation period of three weeks or more. The physical parameters of the lenses tested showed no changes beyond that allowed by the ISO guidelines. Incubations with the ATS found that balafilcon A lenses deposit significantly more cholesterol and phosphatidylcholine than omafilcon A lenses (p<0.05) and that removing lactoferrin and immunoglobulin G from the ATS can significantly decrease the mass of lipid deposited. Conclusions This paper describes a novel complex artificial tear solution specially designed for in-vial incubation of contact lens materials. This solution was stable and did not adversely affect the physical parameters of the soft contact lenses incubated within it and showed that lipid deposition was responsive to changes in ATS composition. PMID:22219635

  19. Deep Brain Stimulation of the Dentato-Rubro-Thalamic Tract: Outcomes of Direct Targeting for Tremor.

    PubMed

    Fenoy, Albert J; Schiess, Mya C

    2017-07-01

    Targeting the dentato-rubro-thalamic tract (DRTt) has been suggested to be efficacious in deep brain stimulation (DBS) for tremor suppression, both in case reports and post-hoc analyses. This prospective observational study sought to analyze outcomes after directly targeting the DRTt in tremor patients. 20 consecutively enrolled intention tremor patients obtained pre-operative MRI with diffusion tensor (dTi) sequences. Mean baseline tremor amplitude based on The Essential Tremor Rating Assessment Scale was recorded. The DRTt was drawn for each individual on StealthViz software (Medtronic) using the dentate nucleus as the seed region and the ipsilateral pre-central gyrus as the end region and then directly targeted during surgery. Intraoperative testing confirmed successful tremor control. Post-operative analysis of electrode position relative to the DRTt was performed, as was post-operative assessment of tremor improvement. The mean age of patients was 66.8 years; mean duration of tremor was 16 years. Mean voltage for the L electrode = 3.4 V; R = 2.6 V. Mean distance from the center of the active electrode contact to the DRTt was 0.9 mm on the L, and 0.8 mm on the R. Improvement in arm tremor amplitude from baseline after DBS was significant (P < 0.001). Direct targeting of the DRTt in DBS is an effective strategy for tremor suppression. Accounting for hardware, software, and model limitations, depiction of the DRTt allows for placement of electrode contacts directly within the fiber tract for modulation despite any anatomical variation, which reproducibly resulted in good tremor control. © 2017 International Neuromodulation Society.

  20. Hand-touch contact assessment of high-touch and mutual-touch surfaces among healthcare workers, patients, and visitors.

    PubMed

    Cheng, V C C; Chau, P H; Lee, W M; Ho, S K Y; Lee, D W Y; So, S Y C; Wong, S C Y; Tai, J W M; Yuen, K Y

    2015-07-01

    Unlike direct contact with patients' body, hand hygiene practice is often neglected by healthcare workers (HCWs) and visitors after contact with patients' environment. Contact with hospital environmental items may increase risk of pathogen transmission. To enumerate the number of hand-touch contacts by patients, HCWs and visitors with any hospital environmental items. All contact-episodes between person and item were recorded by direct observation in a six-bed cubicle of acute wards for 33 working days. High-touch and mutual-touch items with high contact frequencies by HCWs, patients, and visitors were analysed. In total, 1107 person-episodes with 6144 contact-episodes were observed in 66 observation hours (average: 16.8 person-episodes and 93.1 contact-episodes per hour). Eight of the top 10 high-touch items, including bedside rails, bedside tables, patients' bodies, patients' files, linen, bed curtains, bed frames, and lockers were mutually touched by HCWs, patients, and visitors. Bedside rails topped the list with 13.6 contact-episodes per hour (mean), followed by bedside tables (12.3 contact-episodes per hour). Using patients' body contacts as a reference, it was found that medical staff and nursing staff contacted bedside tables [rate ratio (RR): 1.741, 1.427, respectively] and patients' files (RR: 1.358, 1.324, respectively) more than patients' bodies, and nursing staff also contacted bedside rails (RR: 1.490) more than patients' bodies. Patients' surroundings may be links in the transmission of nosocomial infections because many are frequently touched and mutually contacted by HCWs, patients, and visitors. Therefore, the focus of hand hygiene education, environmental disinfection, and other system changes should be enhanced with respect to high-touch and mutual-touch items. Copyright © 2015 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  1. Knee Muscular Control During Jump Landing in Multidirections.

    PubMed

    Sinsurin, Komsak; Vachalathiti, Roongtiwa; Jalayondeja, Wattana; Limroongreungrat, Weerawat

    2016-06-01

    Jump landing is a complex movement in sports. While competing and practicing, athletes frequently perform multi-planar jump landing. Anticipatory muscle activity could influence the amount of knee flexion and prepare the knee for dynamic weight bearing such as landing tasks. The aim of the present study was to examine knee muscle function and knee flexion excursion as athletes naturally performed multi-direction jump landing. Eighteen male athletes performed the jump-landing test in four directions: forward (0°), 30° diagonal, 60° diagonal, and lateral (90°). Muscles tested were vastus medialis (VM), vastus lateralis (VL), rectus femoris (RF), semitendinosus (ST), and biceps femoris (BF). A Vicon(TM) 612 workstation collected the kinematic data. An electromyography was synchronized with the Vicon(TM) Motion system to quantify dynamic muscle function. Repeated measure ANOVA was used to analyze the data. Jump-landing direction significantly influenced (P < 0.05) muscle activities of VL, RF, and ST and knee flexion excursion. Jumpers landed with a trend of decreasing knee flexion excursion and ST muscle activity 100 ms before foot contact progressively from forward to lateral directions of jump landing. A higher risk of knee injury might occur during lateral jump landing than forward and diagonal directions. Athletes should have more practice in jump landing in lateral direction to avoid injury. Landing technique with high knee flexion in multi-directions should be taught to jumpers for knee injury prevention.

  2. Simulation of hypervelocity impacts using a contact charge

    NASA Astrophysics Data System (ADS)

    Giblin, I.; Martelli, G.; Smith, P. N.; di Martino, M.

    1994-12-01

    Two sets of hypervelocity impact experiments have been performed in the open using a contact charge technique and recorded using fast-framing cameras. It has been possible to record the uninterrupted ballistic trajectories of fragments from the catastrophically disrupted targets, together with their velocity and rotational properties directly after the impact, as well as their size. By performing these experiments in the open and on fairly soft ground, secondary fragmentation normally caused by impact onto the walls or floor of a test chamber has been minimized. A total of 10 experiments have been performed using targets of artificial rock which were either homogeneous, cored or carefully pre-fractured. We report here on the analysis of some of these data using a computer and special software written and developed by our group, with an indication of the results obtained.

  3. Tuberculosis and latent infection in employees of different prison unit types

    PubMed Central

    Nogueira, Péricles Alves; Abrahão, Regina Maura Cabral de Melo; Galesi, Vera Maria Neder; López, Rossana Verónica Mendoza

    2018-01-01

    ABSTRACT OBJECTIVE Estimate the prevalence of active tuberculosis and latent tuberculosis infection among the staff that is in contact and the staff that is not in contact with prisoners, and investigate factors associated with latent tuberculosis infection in this population. METHODS Observational cross-sectional study, conducted from 2012 to 2015, in employees of different prison units in the municipality of Franco da Rocha, SP. It consisted of the application of a questionnaire, application and reading of the tuberculin test, sputum smear microscopy, sputum culture, and radiological examination. The association between the qualitative variables was calculated by the Pearson's chi-squared test. The sociodemographic and clinical-epidemiological factors related to the latent tuberculosis infection were evaluated by the logistic regression with the odds ratios (OR) calculation and their respective intervals with 95% of confidence (95%CI). RESULTS A total of 1,059 employees were examined, 657 (62.0%) of prisons, 249 (23.5%) of CASA Foundation units and 153 (14.5%) of custodial and psychiatric treatment hospitals. The tuberculin test was applied and read for 945 (89.2%) professionals. Of these, 797 (84.3%) were contacts of detainees and 148 (15.7%) were not. Among prison staff, the factors associated with latent tuberculosis infection were: contact with detainee (OR = 2.12, 95%CI 1.21–3.71); male gender (OR = 1.97, 95%CI 1.19–3.27); between 30 and 39 years old (OR = 2.98, 95%CI 1.34–6.63), 40 to 49 years old (OR = 4.32, 95%CI 1.94–9.60), and 50 to 59 years old (OR = 3.98, 95%CI 1.68–9.43); nonwhite color or race (OR = 1.89, 95%CI 1.29–2.78); and smoker (OR = 1.64, 95%CI 1.05–2.55). There were no positive test on sputum smear microscopy and culture. Of the 241 (22.8%) professionals who underwent radiological examination, 48 (19.9%) presented alterations of which 11 were suspected of tuberculosis. CONCLUSIONS Prison employees who have direct contact with detainees are 2.12 times more likely to become infected with Mycobacterium tuberculosis in the work environment and consequently to become ill with tuberculosis and should be targeted for disease prevention and control. PMID:29412377

  4. Reducing Therapist Contact in Parenting Programs: Evaluation of Internet-Based Treatments for Child Conduct Problems

    PubMed Central

    Rabbitt, Sarah M.; Carrubba, Erin; Lecza, Bernadette; McWhinney, Emily; Pope, Jennifer; Kazdin, Alan E.

    2016-01-01

    This study evaluated two Internet-based versions of Parent Management Training (PMT) and the effects of greatly reducing the contact required of a mental health professional on treatment of children referred for conduct problems. We were interested whether reduced contact with a therapist influenced treatment outcome, therapeutic alliance, parent adherence to treatment prescriptions, and parent reactions to and evaluations of the treatment procedures. Sixty children and their caregivers were assigned to receive either Full Contact PMT (with the amount of weekly contact similar to traditional PMT; approximately 50 minutes of direct therapist contact each week) or Reduced Contact PMT (with most information provided through recordings; approximately 10 minutes of therapist contact each week). Children in both groups showed significant and similar reductions in antisocial behaviors specifically, internalizing and externalizing symptoms more generally, and improvements in overall adaptive functioning. Therapeutic alliance also was similar across the two treatment groups. However, parents rated Full Contact treatment as more acceptable than the reduced version. Both treatments were similar in outcomes to in-person treatment as evaluated by a nonrandomized matched sample used as a benchmark in supplementary analyses. Overall, the findings indicate that therapist contact can be reduced while positive treatment outcomes are maintained but that interventions that reduce direct time with a therapist may be viewed less positively by clients. PMID:27453678

  5. 2D Analytical Model for the Directivity Prediction of Ultrasonic Contact Type Transducers in the Generation of Guided Waves.

    PubMed

    Tiwari, Kumar Anubhav; Raisutis, Renaldas; Mazeika, Liudas; Samaitis, Vykintas

    2018-03-26

    In this paper, a novel 2D analytical model based on the Huygens's principle of wave propagation is proposed in order to predict the directivity patterns of contact type ultrasonic transducers in the generation of guided waves (GWs). The developed model is able to estimate the directivity patterns at any distance, at any excitation frequency and for any configuration and shape of the transducers with prior information of phase dispersive characteristics of the guided wave modes and the behavior of transducer. This, in turn, facilitates to choose the appropriate transducer or arrays of transducers, suitable guided wave modes and excitation frequency for the nondestructive testing (NDT) and structural health monitoring (SHM) applications. The model is demonstrated for P1-type macro-fiber composite (MFC) transducer glued on a 2 mm thick aluminum (Al) alloy plate. The directivity patterns of MFC transducer in the generation of fundamental guided Lamb modes (the S0 and A0) and shear horizontal mode (the SH0) are successfully obtained at 80 kHz, 5-period excitation signal. The results are verified using 3D finite element (FE) modelling and experimental investigation. The results obtained using the proposed model shows the good agreement with those obtained using numerical simulations and experimental analysis. The calculation time using the analytical model was significantly shorter as compared to the time spent in experimental analysis and FE numerical modelling.

  6. Dog Breed Differences in Visual Communication with Humans.

    PubMed

    Konno, Akitsugu; Romero, Teresa; Inoue-Murayama, Miho; Saito, Atsuko; Hasegawa, Toshikazu

    2016-01-01

    Domestic dogs (Canis familiaris) have developed a close relationship with humans through the process of domestication. In human-dog interactions, eye contact is a key element of relationship initiation and maintenance. Previous studies have suggested that canine ability to produce human-directed communicative signals is influenced by domestication history, from wolves to dogs, as well as by recent breed selection for particular working purposes. To test the genetic basis for such abilities in purebred dogs, we examined gazing behavior towards humans using two types of behavioral experiments: the 'visual contact task' and the 'unsolvable task'. A total of 125 dogs participated in the study. Based on the genetic relatedness among breeds subjects were classified into five breed groups: Ancient, Herding, Hunting, Retriever-Mastiff and Working). We found that it took longer time for Ancient breeds to make an eye-contact with humans, and that they gazed at humans for shorter periods of time than any other breed group in the unsolvable situation. Our findings suggest that spontaneous gaze behavior towards humans is associated with genetic similarity to wolves rather than with recent selective pressure to create particular working breeds.

  7. Lack of Marburg Virus Transmission From Experimentally Infected to Susceptible In-Contact Egyptian Fruit Bats.

    PubMed

    Paweska, Janusz T; Jansen van Vuren, Petrus; Fenton, Karla A; Graves, Kerry; Grobbelaar, Antoinette A; Moolla, Naazneen; Leman, Patricia; Weyer, Jacqueline; Storm, Nadia; McCulloch, Stewart D; Scott, Terence P; Markotter, Wanda; Odendaal, Lieza; Clift, Sarah J; Geisbert, Thomas W; Hale, Martin J; Kemp, Alan

    2015-10-01

    Egyptian fruit bats (Rousettus aegyptiacus) were inoculated subcutaneously (n = 22) with Marburg virus (MARV). No deaths, overt signs of morbidity, or gross lesions was identified, but microscopic pathological changes were seen in the liver of infected bats. The virus was detected in 15 different tissues and plasma but only sporadically in mucosal swab samples, urine, and fecal samples. Neither seroconversion nor viremia could be demonstrated in any of the in-contact susceptible bats (n = 14) up to 42 days after exposure to infected bats. In bats rechallenged (n = 4) on day 48 after infection, there was no viremia, and the virus could not be isolated from any of the tissues tested. This study confirmed that infection profiles are consistent with MARV replication in a reservoir host but failed to demonstrate MARV transmission through direct physical contact or indirectly via air. Bats develop strong protective immunity after infection with MARV. © The Author 2015. Published by Oxford University Press on behalf of the Infectious Diseases Society of America. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.

  8. Gamete donors' reasons for, and expectations and experiences of, registration with a voluntary donor linking register.

    PubMed

    Blyth, Eric; Crawshaw, Marilyn; Frith, Lucy; van den Akker, Olga

    2017-12-01

    This paper reports on a study of the views and experiences of 21 sperm donors and five egg donors registered with UK DonorLink (UKDL), a voluntary DNA-based contact register established to facilitate contact between adults who wish to identify and locate others to whom they are genetically related following donor conception. Specifically, the paper examines donors' reasons for searching for, or making information about themselves available to donor-conceived offspring. Their expectations of registration with UKDL, experiences of being registered and finally, the experiences of those who had contacted donor-conceived offspring and other genetic relatives are investigated. While most respondents reported largely positive experiences of registration, the study found significant issues relating to concerns about donation, DNA testing, possible linking with offspring and expectations of any relationship that might be established with offspring that have implications for support, mediation and counselling. Research that puts the experiences, perceptions and interests of gamete donors as the central focus of study is a relatively recent phenomenon. This study contributes to this debate and highlights directions for future research in this area.

  9. Study on portable optical 3D coordinate measuring system

    NASA Astrophysics Data System (ADS)

    Ren, Tongqun; Zhu, Jigui; Guo, Yinbiao

    2009-05-01

    A portable optical 3D coordinate measuring system based on digital Close Range Photogrammetry (CRP) technology and binocular stereo vision theory is researched. Three ultra-red LED with high stability is set on a hand-hold target to provide measuring feature and establish target coordinate system. Ray intersection based field directional calibrating is done for the intersectant binocular measurement system composed of two cameras by a reference ruler. The hand-hold target controlled by Bluetooth wireless communication is free moved to implement contact measurement. The position of ceramic contact ball is pre-calibrated accurately. The coordinates of target feature points are obtained by binocular stereo vision model from the stereo images pair taken by cameras. Combining radius compensation for contact ball and residual error correction, object point can be resolved by transfer of axes using target coordinate system as intermediary. This system is suitable for on-field large-scale measurement because of its excellent portability, high precision, wide measuring volume, great adaptability and satisfying automatization. It is tested that the measuring precision is near to +/-0.1mm/m.

  10. Performance and reliability of the Y-Balance TestTM in high school athletes.

    PubMed

    Smith, Laura J; Creps, James R; Bean, Ryan; Rodda, Becky; Alsalaheen, Bara

    2017-11-07

    Lower extremity injuries account for 32.9% of the overall injuries in high school athletes. Previous research has suggested that asymmetry greater than 4cm using the Y-Balance TestTM Lower Quarter (YBT-LQ) in the anterior direction is predictive of non- contact injuries in adults and collegiate athletes. The prevalence of asymmetries or abnormal YBT-LQ performance is not well documented for adolescents. The primary purposes of this study are: 1) to characterize the prevalence of YBT-LQ asymmetries and performance in a cross-sectional sample of adolescents, 2) to examine possible differences in performance on the YBT-LQ between male and female adolescents, and 3) to describe the test-retest reliability of the YBT-LQ in a subsample of adolescents. Observational cross-sectional study. High-school athletes completed the YBT-LQ as main outcome measure. 51 male, 59 female high-school athletes participated in this study. Asymmetries greater than 4cm in the posteromedial (PM) reach direction were most prevalent for male (54.9%) and female (50.8%) participants. Females presented with slightly higher composite scores. Good reliability (ICC = 0.89) was found for the anterior (ANT) direction, and moderate reliability with 0.76 for posterolateral (PL) and 0.63 for PM directions. The MDC95 for the ANT direction was 6% and 12% for both the PL and PM directions. The YBT-LQ performance can be beneficial in assessing recovery in an injured extremity compared to the other limb. However, due to the large MDC95, noted in the PM and PL directions, the differences between sequential testing cannot be attributed to true change in balance unless they exceed the MDC95. In this study, 79% of the athletes presented with at least one asymmetry in YBT-LQ reach distances. Moderate reliability in the PL and PM directions warrants reexamination of the definition of asymmetry in these directions.

  11. Head position affects the direction of occlusal force during tapping movement.

    PubMed

    Nakamura, K; Minami, I; Wada, J; Ikawa, Y; Wakabayashi, N

    2018-05-01

    Despite numerous reports describing the relationship between head position and mandibular movement in human subjects, the direction and magnitude of force at the occlusal contacts have not been investigated in relation to head position. The objective was to investigate the effect of head position on the direction of occlusal force while subjects performed a tapping movement. Twenty-three healthy adult subjects were asked to sit on a chair with their back upright and to perform 15 tapping movements in five different head positions: natural head position (control); forward; backward; and right and left rolled. The direction and magnitude of force were measured using a small triaxial force sensor. The Wilcoxon signed-rank test and Bonferroni test were used to compare head positions in each angle of the anteroposterior axis direction and the lateral axis direction with respect to the superior axis. The force element in the anteroposterior axis shifted to the forward direction in the head position pitched backward, compared with control, pitched forward and rolled left positions (P = .02, <.01 and <.01, respectively). The force direction in the lateral axis with the head position rolled to the right or left shifted to the left and right directions, respectively, compared with those in the other positions (P < .05). Results of this study suggest that the head should be maintained in a position in which a stable tapping movement can be performed in a relaxed position without anteroposterior and lateral loading. © 2018 John Wiley & Sons Ltd.

  12. Optical Testing Using Portable Laser Coordinate Measuring Instruments

    NASA Technical Reports Server (NTRS)

    Khreishi, Manal; Ohl, Raymond G.; Mclean, Kyle F.; Hadjimichael, Theodore J.; Hayden, Joseph E.

    2017-01-01

    High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LR's ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikon's MV-224/350 LR and Leica's Absolute Tracker AT401/402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the "direct and through" (D&T), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the D&T shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.

  13. Effect of vomeronasal organ removal from male mice on their preference for and neural Fos responses to female urinary odors.

    PubMed

    Pankevich, Diana E; Cherry, James A; Baum, Michael J

    2006-08-01

    Four experiments were conducted to determine whether vomeronasal organ (VNO) inputs in male mice mediate the rewarding properties of estrous female urinary odors. Sexually naive male mice with either an intact (VNOi) or lesioned (VNOx) VNO preferred to investigate female urine over water in Y-maze tests. Subsequently, VNOi males ran significantly more quickly and remained in nasal contact longer with estrous female urine than with male urine, whereas VNOx males investigated these odors equally. In home-cage habituation-dishabituation tests, VNOi males also investigated female urine significantly longer than did VNOx males, although both groups investigated female urine longer than other non-body odors. Finally, female urinary odors induced Fos in the nucleus accumbens core of VNOi males but not of VNOx males. Our results suggest that female urinary odors retain some incentive value in VNOx males. However, once direct nasal contact is made with female urine, VNO inputs further activate forebrain mechanisms that amplify the reward salience of this stimulus for the male mouse.

  14. Optical Testing Using Portable Laser Coordinate Measuring Instruments

    NASA Technical Reports Server (NTRS)

    Khreishi, M.; Ohl, R.; Mclean, K.; Hadjimichael, T.; Hayden, J.

    2017-01-01

    High precision, portable coordinate measuring instruments (CMI) such as laser radars (LR) and laser trackers (LT) have been used for optical system alignment and integration. The LRs ability to perform a non-contact scan of surfaces was previously utilized to characterize large spherical and aspheric mirrors. In this paper, we explore the use of a CMI as an accurate, fast, robust, and non-contact tool for prescription characterization of powered optical surfaces. Using Nikons MV-224350 LR and Leicas Absolute Tracker AT401402 instruments, proof of concept measurements were performed to characterize a variety of optical components by measuring the actual and apparent, or equivalently the direct and through (DT), coordinates of calibrated metrology targets. Custom macros in metrology software and other data reduction code were developed to compute surface-ray intercepts and surface slopes from the DT shots. The calculated data is fit to an aspheric surface formula to obtain the optimum prescription. The results were compared to the nominal parameters and were crosschecked using LR scans or other approaches. We discuss potential applications across the fields of optical component fabrication and system alignment and testing.

  15. Prediction of inflammatory responses induced by biomaterials in contact with human blood using protein fingerprint from plasma.

    PubMed

    Engberg, Anna E; Nilsson, Per H; Huang, Shan; Fromell, Karin; Hamad, Osama A; Mollnes, Tom Eirik; Rosengren-Holmberg, Jenny P; Sandholm, Kerstin; Teramura, Yuji; Nicholls, Ian A; Nilsson, Bo; Ekdahl, Kristina N

    2015-01-01

    Inappropriate complement activation is often responsible for incompatibility reactions that occur when biomaterials are used. Complement activation is therefore a criterion included in legislation regarding biomaterials testing. However, no consensus is yet available regarding appropriate complement-activation-related test parameters. We examined protein adsorption in plasma and complement activation/cytokine release in whole blood incubated with well-characterized polymers. Strong correlations were found between the ratio of C4 to its inhibitor C4BP and generation of 10 (mainly pro-inflammatory) cytokines, including IL-17, IFN-γ, and IL-6. The levels of complement activation products correlated weakly (C3a) or not at all (C5a, sC5b-9), confirming their poor predictive values. We have demonstrated a direct correlation between downstream biological effects and the proteins initially adhering to an artificial surface after contact with blood. Consequently, we propose the C4/C4BP ratio as a robust, predictor of biocompatibility with superior specificity and sensitivity over the current gold standard. Copyright © 2014 Elsevier Ltd. All rights reserved.

  16. UCSD/FRA non-contact ultrasonic guided-wave system for rail inspection: an update

    NASA Astrophysics Data System (ADS)

    Coccia, Stefano; Phillips, Robert; Nucera, Claudio; Bartoli, Ivan; Salamone, Salvatore; Lanza di Scalea, Francesco; Fateh, Mahmood; Carr, Gary

    2011-04-01

    The University of California at San Diego (UCSD), under a Federal Railroad Administration (FRA) Office of Research and Development (R&D) grant, is developing a system for high-speed and non-contact rail defect detection. A prototype has been designed and field tested with the support of Volpe National Transportation Systems Center and ENSCO, Inc. The goal of this project is to develop a rail defect detection system that provides (a) better defect detection reliability (including internal transverse head defects under shelling and vertical split head defects), and (b) higher inspection speed than achievable by current rail inspection systems. This effort is also in direct response to Safety Recommendations issued by the National Transportation Safety Board (NTSB) following the disastrous train derailments at Superior, WI in 1992 and Oneida, NY in 2007 among others. The UCSD prototype uses non-contact ultrasonic probing of the rail head (laser and air-coupled), ultrasonic guided waves, and a proprietary real-time statistical analysis algorithm that maximizes the sensitivity to defects while minimizing false positives. The current design allows potential inspection speeds up to 40 mph, although all field tests have been conducted up to 15 mph so far. This paper summarizes (a) the latest technology development test conducted at the rail defect farm of Herzog, Inc. in St Joseph, MO in June 2010, and (b) the completion of the new Rail Defect Farm facility at the UCSD Camp Elliott Field Station with partial in-kind donations from the Burlington Northern Santa Fe (BNSF) Railway.

  17. Contact Dermatitis to Personal Sporting Equipment in Youth.

    PubMed

    Marzario, Barbara; Burrows, Dianne; Skotnicki, Sandy

    2016-07-01

    Contact dermatitis to personal sporting equipment in youth is poorly studied. To review the results of patch testing 6 youth to their sporting equipment in a dermatology general private practice from 2006 to 2011. A retrospective analysis of 6 youth aged 11 to 14 who were evaluated for chronic and persistent dermatitis occurring in relation to sports equipment was conducted. All patients were subjected to epicutaneous (patch) testing, which included some or all of the following: North American Contact Dermatitis Group (NACGD) series, textile series, rubber series, corticosteroid series, and raw material from the patients' own personal equipment. All cases had 1 or more positive patch test reactions to an allergen within the aforementioned series, and 3 subjects tested positive to their personal equipment in raw form. Allergic contact dermatitis, not irritant, was deemed the relevant cause of chronic dermatitis in 4 of the 6 patients due to positive reactions to epicutaneous tests and/or personal equipment. The utility of testing to patients' own sporting equipment was shown to be of additional value and should be considered when patch testing for contact allergy to sporting equipment. © The Author(s) 2015.

  18. Multi-stage flash degaser

    DOEpatents

    Rapier, Pascal M.

    1982-01-01

    A multi-stage flash degaser (18) is incorporated in an energy conversion system (10) having a direct-contact, binary-fluid heat exchanger to remove essentially all of the noncondensable gases from geothermal brine ahead of the direct-contact binary-fluid heat exchanger (22) in order that the heat exchanger (22) and a turbine (48) and condenser (32) of the system (10) can operate at optimal efficiency.

  19. 26 CFR 601.506 - Notices to be given to recognized representative; direct contact with taxpayer; delivery of a...

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... representative; direct contact with taxpayer; delivery of a check drawn on the United States Treasury to... taxpayer; delivery of a check drawn on the United States Treasury to recognized representative. (a) General... disciplinary proceedings under Circular No. 230, 31 CFR part 10. (c) Delivery of a check drawn on the United...

  20. Direkte Kontakte zu Deutschland aus und in der Ferne (Direct Contact with Germany from and at a Distance).

    ERIC Educational Resources Information Center

    Wicke, Rainer E.

    This guide is a summary of ideas for enhancing the teaching of German through direct contact with Germany or German people without traveling abroad. The following ideas are highlighted: (1) correspondence (pen pals) with students in Germany; (2) audiotape recordings as an alternative to letter writing; (3) the exchange of videotape recordings with…

Top