Sample records for direct count aodc

  1. Characterization of Volume F Trash from Four Recent STS Missions: Microbial Occurrence, Numbers, and Identifications

    NASA Technical Reports Server (NTRS)

    Strayer, Richard F.; Hummerick, Mary E.; Richards, Jeffrey T.; McCoy, LaShelle E.; Roberts, Michael S.; Wheeler, Raymond M.

    2011-01-01

    The fate of space-generated solid wastes, including trash, for future missions is under consideration by NASA. Several potential treatment options are under active technology development. Potential fates for space-generated solid wastes: Storage without treatment; storage after treatment(s) including volume reduction, water recovery, sterilization, and recovery plus recycling of waste materials. For this study, a microbial characterization was made on trash returned from four recent STS missions. The material analyzed were 'Volume F' trash and other bags of accompanying trash. This is the second of two submitted papers on these wastes. This first one covered trash content, weight and water content. Upon receipt, usually within 2 days of landing, trash contents were catalogued and placed into categories: drink containers, food waste, personal hygiene items, and packaging materials, i.e., plastic film and duct tape. Microbial counts were obtained with cultivatable counts on agar media and direct counts using Acridine Orange fluorescent stain (AODC). Trash bag surfaces, 25 square cm , were also sampled. Direct counts were approximately 1 x 10(exp 6) microbes/square cm and cultivatable counts ranged from 1 x 10 to 1 X 10(exp 4) microbes/ square cm-2. Aerobic microbes, aerobic sporeformers, and yeasts plus molds were common for all four missions. Waste items from each category were placed into sterile ziplock bags and 1.5 L sterile DI water added. These were then dispersed by hand shaking for 2 min. prior to inoculation of count media or determining AODC. In general, cultivatable microbes were found in drinks, food wastes, and personal hygiene items. Direct counts were usually higher than cultivatable counts. Some pathogens were found: Staphylococcus auerus, Escherichia coli (fecal wastes). Count ranges: drink pouches - AODC 2 x 10(exp 6) to 1 X 10(exp 8) g(sub fw) (exp -1); cultivatable counts variable between missions; food wastes: Direct counts were close to aerobic plate counts. Counts ranged from 10(exp 6) to 10(exp 9) per g(sub fw). Identities of isolates from cultivation media were obtained using a Biolog Microbial ID System or microSEQ molecular ID methodology using an ABI3130 gene analyzer.

  2. Immunological techniques as tools to characterize the subsurface microbial community at a trichloroethylene contaminated site

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Fliermans, C.B.; Dougherty, J.M.; Franck, M.M.

    Effective in situ bioremediation strategies require an understanding of the effects pollutants and remediation techniques have on subsurface microbial communities. Therefore, detailed characterization of a site`s microbial communities is important. Subsurface sediment borings and water samples were collected from a trichloroethylene (TCE) contaminated site, before and after horizontal well in situ air stripping and bioventing, as well as during methane injection for stimulation of methane-utilizing microorganisms. Subsamples were processed for heterotrophic plate counts, acridine orange direct counts (AODC), community diversity, direct fluorescent antibodies (DFA) enumeration for several nitrogen-transforming bacteria, and Biolog {reg_sign} evaluation of enzyme activity in collected water samples.more » Plate counts were higher in near-surface depths than in the vadose zone sediment samples. During the in situ air stripping and bioventing, counts increased at or near the saturated zone, remained elevated throughout the aquifer, but did not change significantly after the air stripping. Sporadic increases in plate counts at different depths as well as increased diversity appeared to be linked to differing lithologies. AODCs were orders of magnitude higher than plate counts and remained relatively constant with depth except for slight increases near the surface depths and the capillary fringe. Nitrogen-transforming bacteria, as measured by serospecific DFA, were greatly affected both by the in situ air stripping and the methane injection. Biolog{reg_sign} activity appeared to increase with subsurface stimulation both by air and methane. The complexity of subsurface systems makes the use of selective monitoring tools imperative.« less

  3. Use of immunomagnetic separation for the detection of Desulfovibrio vulgaris from environmental samples

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Chakraborty, R.; Hazen, T.C.; Joyner, D.C.

    2011-04-15

    Immunomagnetic separation (IMS) has proved highly efficient for recovering microorganisms from heterogeneous samples. Current investigation targeted the separation of viable cells of the sulfate-reducing bacterium, Desulfovibrio vulgaris. Streptavidin-coupled paramagnetic beads and biotin labeled antibodies raised against surface antigens of this microorganism were used to capture D. vulgaris cells in both bioreactor grown laboratory samples and from extremely low-biomass environmental soil and subsurface drilling samples. Initial studies on detection, recovery efficiency and viability for IMS were performed with laboratory grown D. vulgaris cells using various cell densities. Efficiency of cell isolation and recovery (i.e., release of the microbial cells from themore » beads following separation) was followed by microscopic imaging and acridine orange direct counts (AODC). Excellent recovery efficiency encouraged the use of IMS to capture Desulfovibrio spp. cells from low-biomass environmental samples. The environmental samples were obtained from a radionuclide-contaminated site in Germany and the chromium (VI)-contaminated Hanford site, an ongoing bioremediation project of the U.S. Department of Energy. Field deployable IMS technology may greatly facilitate environmental sampling and bioremediation process monitoring and enable transcriptomics and proteomics/metabolomics-based studies directly on cells collected from the field.« less

  4. Nucleic acid based quantitative microbial community analysis in different marine and terrestrial sediments

    NASA Astrophysics Data System (ADS)

    Schippers, A.; Blazejak, A.; Köweker, G.

    2009-12-01

    Sub-seafloor sediments harbour over half of all prokaryotic cells on Earth. This immense cell number is calculated from numerous microscopic cell counts (AODC) in ODP sediment cores. Since AODC can not differentiate between living or dead cells, the population size of living microorganisms and the abundance of different prokaryotic groups are unknown. Recent molecular nucleic acid and biomarker analyses showed that a high proportion of the cells are alive and that the microbial communities of deep marine sediments harbour members of distinct, uncultured bacterial and archaeal lineages. The main objective of our project is the quantification of living prokaryotes in various sediments. Deep sediment samples from the Pacific and the Atlantic Oceans (ODP Legs 201 and 207, IODP Exp. 307 and 308), sediments from the Indian Ocean (RV Sonne 189-2) and the Black Sea (RV Meteor 51/4) as well as terrestrial Chesapeake Bay Sediments (ICDP) were analyzed using Catalyzed Reporter Deposition - Fluorescence In Situ Hybridisation (CARD - FISH) and quantitative, real-time PCR (Q-PCR), targeting either the 16S rRNA gene or the functional genes dsrA, mcrA and aprA to quantify microorganisms of various phylogenetic or physiological groups (e.g. JS1 cluster and Chloroflexi). At all sediment sites, cell numbers decreased with depth, however, the abundance of particular microbial groups varied at different sites and depths. The results indicate that global estimates of the deep biosphere should be reconsidered.

  5. Aerosol optical properties of Western Mediterranean basin from multi-year AERONET data

    NASA Astrophysics Data System (ADS)

    Benkhalifa, Jamel; Léon, Jean François; Chaabane, Mabrouk

    2017-11-01

    Aerosol optical properties including the total and coarse mode aerosol extinction optical depth (AODt and AODc respectively), Angstrom exponent (AE), size distribution, single scattering albedo (SSA) were examined using long-term ground-based radiometric measurements at 9 sites in the Western Mediterranean: Oujda, Malaga, Barcelona, Carpentras, Rome Tor Vergata, Ersa, Ispra, Venice and Evora, during the 4-year study period (2010-2013). The South-North gradient in the fraction of AODc represents the signature of the increasing influence of coarse particles on the optical properties at southern stations. This fraction has a daily mean ranging from 48 ± 18% at the southern site Oujda and to 8 ± 8% at Ispra. The low average AE444-870 value (<0.7) at Oujda confirms the major influence of large dust particles. Conversely, the AOD at urban stations are dominated by fine mode particles. The Angstrom Exponent (AE444-870) above 1.5 in Ispra and Venice indicates an atmospheric situation corresponding to the urban pollution controlled by small particles. We have analyzed the intrinsic dust optical properties by selecting the dusty days corresponding to a total optical depth above 0.3 and a fraction of the coarse mode optical depth above 30%. For these cases, the mean AODt during dusty days was shown to be close to 0.4. During dusty days, the coarse mode fraction represents 88% of the total volume at Oudja and above 83% for all other sites. There is a weak variability in the mean coarse mode volume median radius, showing an average of 1.98 ± 0.1. A maximum in the AODc was observed in the summer of 2012, with particular high events on June 27. The forward trajectory starting at Evora on June 27 clearly indicates that all the sites were affected by such dust events in the following days.

  6. Microcosm studies of subsurface PAH-degrading bacteria from a former manufactured gas plant

    NASA Astrophysics Data System (ADS)

    Durant, Neal D.; Wilson, Liza P.; Bouwer, Edward J.

    1995-01-01

    A study was conducted to evaluate the potential for natural in situ biodegradation of polycyclic aromatic hydrocarbons (PAH's) in the subsurface at the site of a former manufactured gas plant. Fifty-seven samples of unconsolidated subsurface sediments were aseptically obtained from five boreholes across the site. Bacteria capable of aerobically degrading PAH's without an acclimation period were detected throughout shallow (2.7 m) and deep (24.7 m) areas of the subsurface in both relatively clean (<20 μg L -1 naphthalene) and contaminated (4400 μg L -1 naphthalene) zones. Significant ( p < 0.05) quantities of naphthalene (8±3% to 43±7%) and/or phenanthrene (3±1% to 31±3%) were mineralized in sediment-groundwater microcosms during 4 weeks of aerobic incubation at 22°C. Three samples out of 11 were able to aerobically mineralize significant quantities of benzene (6±2% to 24±1%). Of 11 samples tested for anaerobic mineralization, naphthalene biodegradation (7±1% to 13±2%) in the presence of N03 was observed in two samples. Compound removals were first order with respect to substrate concentration during the first 10-15 days of incubation. Compound biodegradation plateaued in the later stages of incubation (15-40 days), most likely from diminishing bioavailability and nutrient and oxygen depletion. Population densities in the sediments were typically low, with viable aerobic counts ranging from 0 to 10 5 CFU gdw -1, viable anaerobic counts ranging from 0 to 104 CFU gdw -1, and total counts (AODC) usually 10-fold greater than viable counts. Total counts exhibited a strong ( p < 0.01) positive correlation with sample grain size. Viable aerobic and anaerobic populations commonly occurred in the same sample, suggesting the presence of facultative anaerobes. Bacteria were metabolically active in samples from groundwaters with low pH (3.7) and high naphthalene concentrations (11,000 μg L -1). Data from these enumeration and microcosm studies suggest that natural in situ biodegradation is occurring at the site.

  7. Legionella in Puerto Rico cooling towers

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Negron-Alviro, A.; Perez-Suarez, I.; Hazen, T.C.

    1988-12-31

    Water samples from air conditioning cooling towers receiving different treatment protocols on five large municipal buildings in San Juan, Puerto Rico were assayed for various species and serogroups of Legionella spp. using direct immunofluorescence. Several water quality parameters were also measured with each sample. Guinea pigs were inoculated with water samples to confirm pathogenicity and recover viable organisms. Legionella pneumophila (1-6), L. bozemanii, L. micdadei, L. dumoffii, and L. gormanii were observed in at least one of the cooling towers. L. pneumophila was the most abundant species, reaching 10{sup 5} cells/ml, within the range that is considered potentially pathogenic tomore » humans. A significantly higher density of L. pneumophila was observed in the cooling tower water that was not being treated with biocides. Percent respiration (INT) and total cell activity (AODC), were inversely correlated with bacterial density. This study demonstrates that Legionella spp. are present in tropical air-conditioning cooling systems, and without continuous biocide treatment may reach densities that present a health risk.« less

  8. Antimicrobial Resources for Disinfection of Potable Water Systems for Future Spacecraft

    NASA Technical Reports Server (NTRS)

    Morford, Megan A.; Birmele, Michele; Roberts, Michael S.

    2012-01-01

    As human exploration adventures beyond low earth orbit, life support systems will require more innovation and research to become self-sustaining and durable. One major concern about future space travel is the ability to store and decontaminate water for consumption and hygiene. This project explores materials and technologies for possible use in future water systems without requiring point-of-use (POU) filtering or chemical additives such as iodine or silver that require multiple doses to remain effective. This experimentation tested the efficacy of a variety of antimicrobial materials against biofilm formation in a high shear CDC Biofilm Reactor (CBR) and some materials in a low shear Drip Flow Reactor (DFR) which(also utilizes ultra violet light emitting diodes (UVLEDs) as an antimicrobial resource. Most materials were tested in the CBR using the ASTM E 2562-07 1method involving the Pseudomonas aeruginosa and coupon samples that vary in their antimicrobial coatings and surface layer topographies. In a controlled environmental chamber (CEC), the CBR underwent a batch phase, continuous flow phase (CFP), and a harvest before analysis. The DFR portion of this experimentation was performed in order to assess the antimicrobial capabilities of ultraviolet-A LEDs (UV-A) in potable water systems. The ASTM E 2647-08 was modified in order to incorporate UV-A LEDs and to operate as a closed, re-circulating system. The modified DFR apparatus that was utilized contains 4 separate channels each of which contain 2 UV-A LEDs (1 chamber is masked off to serve as a control) and each channel is equipped with its own reservoir and peristaltic pump head. The 10 DFR runs discussed in this report include 4 initial experimental runs that contained blank microscope slides to test the UVA LEDs alone, 2 that incorporated solid silver coupons, 2 that utilized titanium dioxide (Ti02) coupons as a photocatalyst, and 2 runs that utilized silver coated acrylic slides. Both the CBR and DFR experiments were analyzed for microbial content via heterotrophic plate counts (HPC) and acridine orange direct counts (AODC). Ofthe materials used in the CBR, only two materials performed as antiicrobials under high shear conditions (a reduction of 5 or more logs) showing a>7 log reduction in viable microbes.

  9. Characterization of microbial and chemical composition of shuttle wet waste with permanent gas and volatile organic compound analyses

    NASA Astrophysics Data System (ADS)

    Peterson, B. V.; Hummerick, M.; Roberts, M. S.; Krumins, V.; Kish, A. L.; Garland, J. L.; Maxwell, S.; Mills, A.

    2004-01-01

    Solid-waste treatment in space for Advanced Life Support, ALS, applications requires that the material can be safely processed and stored in a confined environment. Many solid-wastes are not stable because they are wet (40-90% moisture) and contain levels of soluble organic compounds that can contribute to the growth of undesirable microorganisms with concomitant production of noxious odors. In the absence of integrated Advanced Life Support systems on orbit, permanent gas, trace volatile organic and microbiological analyses were performed on crew refuse returned from the volume F "wet" trash of three consecutive Shuttle missions (STS-105, 109, and 110). These analyses were designed to characterize the short-term biological stability of the material and assess potential crew risks resulting from microbial decay processes during storage. Waste samples were collected post-orbiter landing and sorted into packaging material, food waste, toilet waste, and bulk liquid fractions deposited during flight in the volume F container. Aerobic and anaerobic microbial loads were determined in each fraction by cultivation on R2A and by acridine orange direct count (AODC). Dry and ash weights were performed to determine both water and organic content of the materials. Experiments to determine the aerobic and anaerobic biostability of refuse stored for varying periods of time were performed by on-line monitoring of CO 2 and laboratory analysis for production of hydrogen sulfide and methane. Volatile organic compounds and permanent gases were analyzed using EPA Method TO15 by USEPA et al. [EPA Method TO15, The Determination of Volatile Organic Compounds (VOCs) in Ambient Air using SUMMA, Passivated Canister Sampling and Gas Chromatographic Analysis, 1999] with gas chromatography/mass spectrometry and by gas chromatography with selective detectors. These baseline measures of waste stream content, labile organics, and microbial load in the volume F Shuttle trash provide data for waste subsystem analysis and atmospheric management within the ALS Project.

  10. Characterization of microbial and chemical composition of shuttle wet waste with permanent gas and volatile organic compound analyses

    NASA Technical Reports Server (NTRS)

    Peterson, B. V.; Hummerick, M.; Roberts, M. S.; Krumins, V.; Kish, A. L.; Garland, J. L.; Maxwell, S.; Mills, A.

    2004-01-01

    Solid-waste treatment in space for Advanced Life Support, ALS, applications requires that the material can be safely processed and stored in a confined environment. Many solid-wastes are not stable because they are wet (40-90% moisture) and contain levels of soluble organic compounds that can contribute to the growth of undesirable microorganisms with concomitant production of noxious odors. In the absence of integrated Advanced Life Support systems on orbit, permanent gas, trace volatile organic and microbiological analyses were performed on crew refuse returned from the volume F "wet" trash of three consecutive Shuttle missions (STS-105, 109, and 110). These analyses were designed to characterize the short-term biological stability of the material and assess potential crew risks resulting from microbial decay processes during storage. Waste samples were collected post-orbiter landing and sorted into packaging material, food waste, toilet waste, and bulk liquid fractions deposited during flight in the volume F container. Aerobic and anaerobic microbial loads were determined in each fraction by cultivation on R2A and by acridine orange direct count (AODC). Dry and ash weights were performed to determine both water and organic content of the materials. Experiments to determine the aerobic and anaerobic biostability of refuse stored for varying periods of time were performed by on-line monitoring of CO2 and laboratory analysis for production of hydrogen sulfide and methane. Volatile organic compounds and permanent gases were analyzed using EPA Method TO15 by USEPA et al. [EPA Method TO15, The Determination of Volatile Organic Compounds (VOCs) in Ambient Air using SUMMA, Passivated Canister Sampling and Gas Chromatographic Analysis,1999] with gas chromatography/mass spectrometry and by gas chromatography with selective detectors. These baseline measures of waste stream content, labile organics, and microbial load in the volume F Shuttle trash provide data for waste subsystem analysis and atmospheric management within the ALS Project. Published by Elsevier Ltd on behalf of COSPAR.

  11. Characterization of microbial and chemical composition of shuttle wet waste with permanent gas and volatile organic compound analyses.

    PubMed

    Peterson, B V; Hummerick, M; Roberts, M S; Krumins, V; Kish, A L; Garland, J L; Maxwell, S; Mills, A

    2004-01-01

    Solid-waste treatment in space for Advanced Life Support, ALS, applications requires that the material can be safely processed and stored in a confined environment. Many solid-wastes are not stable because they are wet (40-90% moisture) and contain levels of soluble organic compounds that can contribute to the growth of undesirable microorganisms with concomitant production of noxious odors. In the absence of integrated Advanced Life Support systems on orbit, permanent gas, trace volatile organic and microbiological analyses were performed on crew refuse returned from the volume F "wet" trash of three consecutive Shuttle missions (STS-105, 109, and 110). These analyses were designed to characterize the short-term biological stability of the material and assess potential crew risks resulting from microbial decay processes during storage. Waste samples were collected post-orbiter landing and sorted into packaging material, food waste, toilet waste, and bulk liquid fractions deposited during flight in the volume F container. Aerobic and anaerobic microbial loads were determined in each fraction by cultivation on R2A and by acridine orange direct count (AODC). Dry and ash weights were performed to determine both water and organic content of the materials. Experiments to determine the aerobic and anaerobic biostability of refuse stored for varying periods of time were performed by on-line monitoring of CO2 and laboratory analysis for production of hydrogen sulfide and methane. Volatile organic compounds and permanent gases were analyzed using EPA Method TO15 by USEPA et al. [EPA Method TO15, The Determination of Volatile Organic Compounds (VOCs) in Ambient Air using SUMMA, Passivated Canister Sampling and Gas Chromatographic Analysis,1999] with gas chromatography/mass spectrometry and by gas chromatography with selective detectors. These baseline measures of waste stream content, labile organics, and microbial load in the volume F Shuttle trash provide data for waste subsystem analysis and atmospheric management within the ALS Project. Published by Elsevier Ltd on behalf of COSPAR.

  12. The Heterotrophic Bacterial Response During the Meso-scale Southern Ocean Iron Experiment (SOFeX)

    NASA Astrophysics Data System (ADS)

    Oliver, J. L.; Barber, R. T.; Ducklow, H. W.

    2002-12-01

    Previous meso-scale iron enrichments have demonstrated the stimulatory effect of iron on primary productivity and the accelerated flow of carbon into the surface ocean foodweb. In stratified waters, heterotrophic activity can work against carbon export by remineralizing POC and/or DOC back to CO2, effectively slowing the biological pump. To assess the response of heterotrophic activity to iron enrichment, we measured heterotrophic bacterial production and abundance during the Southern Ocean Iron Experiment (SOFeX). Heterotrophic bacterial processes primarily affect the latter of the two carbon export mechanisms, removal of DOC to the deep ocean. Heterotrophic bacterial production (BP), measured via tritiated thymidine (3H-TdR) and leucine (3H-Leu) incorporation, increased ~40% over the 18-d observation period in iron fertilized waters south of the Polar Front (South Patch). Also, South Patch BP was 61% higher than in the surrounding unfertilized waters. Abundance, measured by flow cytometry (FCM) and acridine orange direct counts (AODC), also increased in the South Patch from 3 to 5 x 108 cells liter-1, a 70% increase. Bacterial biomass increased from ~3.6 to 6.3 μg C liter-1, a clear indication that production rates exceeded removal rates (bactivory, viral lysis) over the course of 18 days. Biomass within the fertilized patch was 11% higher than in surrounding unfertilized waters reflecting a similar trend. This pattern is in contrast to SOIREE where no accumulation of biomass was observed. High DNA-containing (HDNA) cells detected by FCM also increased over time in iron fertilized waters from 20% to 46% relative to the total population suggesting an active subpopulation of cells that were growing faster than the removal rates. In iron fertilized waters north of the Polar Front (North Patch), BP and abundance were ~90% and 80% higher, respectively, than in unfertilized waters. Our results suggest an active bacterial population that responded to iron fertilization by utilizing newly produced DOC and/or iron and which grew at rates that exceeded removal rates. Differences in the microbial response between SOFeX and SOIREE are subtle, and may be related to differences in foodweb structure prior to and during the response to iron enrichment.

  13. Up or down? Reading direction influences vertical counting direction in the horizontal plane - a cross-cultural comparison.

    PubMed

    Göbel, Silke M

    2015-01-01

    Most adults and children in cultures where reading text progresses from left to right also count objects from the left to the right side of space. The reverse is found in cultures with a right-to-left reading direction. The current set of experiments investigated whether vertical counting in the horizontal plane is also influenced by reading direction. Participants were either from a left-to-right reading culture (UK) or from a mixed (left-to-right and top-to-bottom) reading culture (Hong Kong). In Experiment 1, native English-speaking children and adults and native Cantonese-speaking children and adults performed three object counting tasks. Objects were presented flat on a table in a horizontal, vertical, and square display. Independent of culture, the horizontal array was mostly counted from left to right. While the majority of English-speaking children counted the vertical display from bottom to top, the majority of the Cantonese-speaking children as well as both Cantonese- and English-speaking adults counted the vertical display from top to bottom. This pattern was replicated in the counting pattern for squares: all groups except the English-speaking children started counting with the top left coin. In Experiment 2, Cantonese-speaking adults counted a square array of objects after they read a text presented to them either in left-to-right or in top-to-bottom reading direction. Most Cantonese-speaking adults started counting the array by moving horizontally from left to right. However, significantly more Cantonese-speaking adults started counting with a top-to-bottom movement after reading the text presented in a top-to-bottom reading direction than in a left-to-right reading direction. Our results show clearly that vertical counting in the horizontal plane is influenced by longstanding as well as more recent experience of reading direction.

  14. Direction Counts: A Comparative Study of Spatially Directional Counting Biases in Cultures with Different Reading Directions

    ERIC Educational Resources Information Center

    Shaki, Samuel; Fischer, Martin H.; Gobel, Silke M.

    2012-01-01

    Western adults associate small numbers with left space and large numbers with right space. Where does this pervasive spatial-numerical association come from? In this study, we first recorded directional counting preferences in adults with different reading experiences (left to right, right to left, mixed, and illiterate) and observed a clear…

  15. Development of spatial preferences for counting and picture naming.

    PubMed

    Knudsen, Birgit; Fischer, Martin H; Aschersleben, Gisa

    2015-11-01

    The direction of object enumeration reflects children's enculturation but previous work on the development of such spatial preferences has been inconsistent. Therefore, we documented directional preferences in finger counting, object counting, and picture naming for children (4 groups from 3 to 6 years, N = 104) and adults (N = 56). We found a right-side preference for finger counting in 3- to 6-year-olds and a left-side preference for counting objects and naming pictures by 6 years of age. Children were consistent in their special preferences when comparing object counting and picture naming, but not in other task pairings. Finally, spatial preferences were not related to cardinality comprehension. These results, together with other recent work, suggest a gradual development of spatial-numerical associations from early non-directional mappings into culturally constrained directional mappings.

  16. SURVIVAL OF SALMONELLA SPECIES IN RIVER WATER.

    EPA Science Inventory

    The survival of four Salmonella strains in river water microcosms was monitored using culturing techniques, direct counts, whole cell hybridization, scanning electron microscopy, and resuscitation techniques via the direct viable count method and flow cytrometry. Plate counts of...

  17. SURVIVAL OF SALMONELLA SPECIES IN RIVER WATER

    EPA Science Inventory

    The survival of four Salmonella strains in river water microcosms was monitored by culturing techniques, direct counts, whole-cell hybridization, scanning electron microscopy, and resuscitation techniques via the direct viable count method and flow cytometry. Plate counts of bact...

  18. An Embodiment Perspective on Number-Space Mapping in 3.5-Year-Old Dutch Children.

    PubMed

    van 't Noordende, Jaccoline E; Volman, M Chiel J M; Leseman, Paul P M; Kroesbergen, Evelyn H

    2017-01-01

    Previous research suggests that block adding, subtracting and counting direction are early forms of number-space mapping. In this study, an embodiment perspective on these skills was taken. Embodiment theory assumes that cognition emerges through sensory-motor interaction with the environment. In line with this assumption, it was investigated if counting and adding/subtracting direction in young children is related to the hand they use during task performance. Forty-eight 3.5-year-old children completed a block adding, subtracting and counting task. They had to add and remove a block from a row of three blocks and count a row of five blocks. Adding, subtracting and counting direction were related to the hand the children used for task performance. Most children who used their right hand added, removed and started counting the blocks at the right side of the row. Most children who used their left hand added, removed and started counting the blocks at the left side of the row. It can be concluded that number-space mapping, as measured by direction of adding, subtracting and counting blocks, in young children is embodied: It is not fixed, but is related to the situation. © 2016 The Authors Infant and Child Development Published by John Wiley & Sons, Ltd.

  19. Rapid enumeration of viable bacteria by image analysis

    NASA Technical Reports Server (NTRS)

    Singh, A.; Pyle, B. H.; McFeters, G. A.

    1989-01-01

    A direct viable counting method for enumerating viable bacteria was modified and made compatible with image analysis. A comparison was made between viable cell counts determined by the spread plate method and direct viable counts obtained using epifluorescence microscopy either manually or by automatic image analysis. Cultures of Escherichia coli, Salmonella typhimurium, Vibrio cholerae, Yersinia enterocolitica and Pseudomonas aeruginosa were incubated at 35 degrees C in a dilute nutrient medium containing nalidixic acid. Filtered samples were stained for epifluorescence microscopy and analysed manually as well as by image analysis. Cells enlarged after incubation were considered viable. The viable cell counts determined using image analysis were higher than those obtained by either the direct manual count of viable cells or spread plate methods. The volume of sample filtered or the number of cells in the original sample did not influence the efficiency of the method. However, the optimal concentration of nalidixic acid (2.5-20 micrograms ml-1) and length of incubation (4-8 h) varied with the culture tested. The results of this study showed that under optimal conditions, the modification of the direct viable count method in combination with image analysis microscopy provided an efficient and quantitative technique for counting viable bacteria in a short time.

  20. EVALUATION OF THE USE OF DIFFERENT ANTIBIOTICS IN THE DIRECT VIABLE COUNT METHOD TO DETECT FECAL ENTEROCOCCI

    EPA Science Inventory

    The detection of fecal pollution is performed via culturing methods in spite of the fact that culturable counts can severely underestimate the densities of fecal microorganisms. One approach that has been used to enumerate bacteria is the direct viable count method (DVC). The ob...

  1. Death of the Escherichia coli K-12 strain W3110 in soil and water.

    PubMed Central

    Bogosian, G; Sammons, L E; Morris, P J; O'Neil, J P; Heitkamp, M A; Weber, D B

    1996-01-01

    Whether Escherichia coli K-12 strain W3110 can enter the "viable but nonculturable" state was studied with sterile and nonsterile water and soil at various temperatures. In nonsterile river water, the plate counts of added E. coli cells dropped to less than 10 CFU/ml in less than 10 days. Acridine orange direct counts, direct viable counts, most-probable-number estimates, and PCR analyses indicated that the added E. coli cells were disappearing from the water in parallel with the number of CFU. Similar results were obtained with nonsterile soil, although the decline of the added E. coli was slower. In sterile water or soil, the added E. coli persisted for much longer, often without any decline in the plate counts even after 50 days. In sterile river water at 37 degrees C and sterile artificial seawater at 20 and 37 degrees C, the plate counts declined by 3 to 5 orders of magnitude, while the acridine orange direct counts remained unchanged. However, direct viable counts and various resuscitation studies all indicated that the nonculturable cells were nonviable. Thus, in either sterile or nonsterile water and soil, the decline in plate counts of E. coli K-12 strain W3110 is not due to the cells entering the viable but nonculturable state, but is simply due to their death. PMID:8900002

  2. Direct measurement of carbon-14 in carbon dioxide by liquid scintillation counting

    NASA Technical Reports Server (NTRS)

    Horrocks, D. L.

    1969-01-01

    Liquid scintillation counting technique is applied to the direct measurement of carbon-14 in carbon dioxide. This method has high counting efficiency and eliminates many of the basic problems encountered with previous techniques. The technique can be used to achieve a percent substitution reaction and is of interest as an analytical technique.

  3. Enumeration of Vibrio cholerae O1 in Bangladesh waters by fluorescent-antibody direct viable count.

    PubMed Central

    Brayton, P R; Tamplin, M L; Huq, A; Colwell, R R

    1987-01-01

    A field trial to enumerate Vibrio cholerae O1 in aquatic environments in Bangladesh was conducted, comparing fluorescent-antibody direct viable count with culture detection by the most-probable-number index. Specificity of a monoclonal antibody prepared against the O1 antigen was assessed and incorporated into the fluorescence staining method. All pond and water samples yielded higher counts of viable V. cholerae O1 by fluorescent-antibody direct viable count than by the most-probable-number index. Fluorescence microscopy is a more sensitive detection system than culture methods because it allows the enumeration of both culturable and nonculturable cells and therefore provides more precise monitoring of microbiological water quality. PMID:3324967

  4. Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination.

    PubMed

    Kitamura, Yutaka; Watanabe, Taisuke; Nakamura, Masayuki; Isobe, Kazushige; Kawabata, Hideo; Uematsu, Kohya; Okuda, Kazuhiro; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki

    2018-01-01

    Platelet-rich fibrin (PRF) clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP) fractions were clotted with CaCl 2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix.

  5. Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination

    PubMed Central

    Kitamura, Yutaka; Watanabe, Taisuke; Nakamura, Masayuki; Isobe, Kazushige; Kawabata, Hideo; Uematsu, Kohya; Okuda, Kazuhiro; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki

    2018-01-01

    Platelet-rich fibrin (PRF) clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP) fractions were clotted with CaCl2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix. PMID:29450197

  6. Relationship between automated total nucleated cell count and enumeration of cells on direct smears of canine synovial fluid.

    PubMed

    Dusick, Allison; Young, Karen M; Muir, Peter

    2014-12-01

    Canine osteoarthritis is a common disorder seen in veterinary clinical practice and causes considerable morbidity in dogs as they age. Synovial fluid analysis is an important tool for diagnosis and treatment of canine joint disease and obtaining a total nucleated cell count (TNCC) is particularly important. However, the low sample volumes obtained during arthrocentesis are often insufficient for performing an automated TNCC, thereby limiting diagnostic interpretation. The aim of the present study was to investigate whether estimation of TNCC in canine synovial fluid could be achieved by performing manual cell counts on direct smears of fluid. Fifty-eight synovial fluid samples, taken by arthrocentesis from 48 dogs, were included in the study. Direct smears of synovial fluid were prepared, and hyaluronidase added before cell counts were obtained using a commercial laser-based instrument. A protocol was established to count nucleated cells in a specific region of the smear, using a serpentine counting pattern; the mean number of nucleated cells per 400 × field was then calculated. There was a positive correlation between the automated TNCC and mean manual cell count, with more variability at higher TNCC. Regression analysis was performed to estimate TNCC from manual counts. By this method, 78% of the samples were correctly predicted to fall into one of three categories (within the reference interval, mildly to moderately increased, or markedly increased) relative to the automated TNCC. Intra-observer and inter-observer agreement was good to excellent. The results of the study suggest that interpretation of canine synovial fluid samples of low volume can be aided by methodical manual counting of cells on direct smears. Copyright © 2014 Elsevier Ltd. All rights reserved.

  7. Direct Detection Electron Energy-Loss Spectroscopy: A Method to Push the Limits of Resolution and Sensitivity.

    PubMed

    Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L

    2017-08-15

    In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.

  8. MEMS PolyMUMPS-Based Miniature Microphone for Directional Sound Sensing

    DTIC Science & Technology

    2007-09-01

    of the translating mode Phir=-atan((2*wr*er*w)/(wr^2-w^2));% Phase constant rocking Phit =-atan((2*wt*et*w)/(wt^2-w^2));% Phase constant translating...2.5e-6)+1 Yl(count)=8e6*(At*sin(w.*t(count)+ Phit ) + Ar*cos(w.*t(count)+Phir)); %left membrane displacement as a function of time in micrometers...Xl(count)=-(((.5)^2-Yl(count).^2).^.5); Yr(count)=8e6*(At*sin(w.*t(count)+ Phit ) - Ar*cos(w.*t(count)+Phir)); %right membrane displacement

  9. Fluorometric determination of the DNA concentration in municipal drinking water.

    PubMed Central

    McCoy, W F; Olson, B H

    1985-01-01

    DNA concentrations in municipal drinking water samples were measured by fluorometry, using Hoechst 33258 fluorochrome. The concentration, extraction, and detection methods used were adapted from existing techniques. The method is reproducible, fast, accurate, and simple. The amounts of DNA per cell for five different bacterial isolates obtained from drinking water samples were determined by measuring DNA concentration and total cell concentration (acridine orange epifluorescence direct cell counting) in stationary pure cultures. The relationship between DNA concentration and epifluorescence total direct cell concentration in 11 different drinking water samples was linear and positive; the amounts of DNA per cell in these samples did not differ significantly from the amounts in pure culture isolates. We found significant linear correlations between DNA concentration and colony-forming unit concentration, as well as between epifluorescence direct cell counts and colony-forming unit concentration. DNA concentration measurements of municipal drinking water samples appear to monitor changes in bacteriological quality at least as well as total heterotrophic plate counting and epifluorescence direct cell counting. PMID:3890737

  10. Comment on: 'A Poisson resampling method for simulating reduced counts in nuclear medicine images'.

    PubMed

    de Nijs, Robin

    2015-07-21

    In order to be able to calculate half-count images from already acquired data, White and Lawson published their method based on Poisson resampling. They verified their method experimentally by measurements with a Co-57 flood source. In this comment their results are reproduced and confirmed by a direct numerical simulation in Matlab. Not only Poisson resampling, but also two direct redrawing methods were investigated. Redrawing methods were based on a Poisson and a Gaussian distribution. Mean, standard deviation, skewness and excess kurtosis half-count/full-count ratios were determined for all methods, and compared to the theoretical values for a Poisson distribution. Statistical parameters showed the same behavior as in the original note and showed the superiority of the Poisson resampling method. Rounding off before saving of the half count image had a severe impact on counting statistics for counts below 100. Only Poisson resampling was not affected by this, while Gaussian redrawing was less affected by it than Poisson redrawing. Poisson resampling is the method of choice, when simulating half-count (or less) images from full-count images. It simulates correctly the statistical properties, also in the case of rounding off of the images.

  11. Comparison of fluorescence microscopy and solid-phase cytometry methods for counting bacteria in water

    USGS Publications Warehouse

    Lisle, John T.; Hamilton, Martin A.; Willse, Alan R.; McFeters, Gordon A.

    2004-01-01

    Total direct counts of bacterial abundance are central in assessing the biomass and bacteriological quality of water in ecological and industrial applications. Several factors have been identified that contribute to the variability in bacterial abundance counts when using fluorescent microscopy, the most significant of which is retaining an adequate number of cells per filter to ensure an acceptable level of statistical confidence in the resulting data. Previous studies that have assessed the components of total-direct-count methods that contribute to this variance have attempted to maintain a bacterial cell abundance value per filter of approximately 106 cells filter-1. In this study we have established the lower limit for the number of bacterial cells per filter at which the statistical reliability of the abundance estimate is no longer acceptable. Our results indicate that when the numbers of bacterial cells per filter were progressively reduced below 105, the microscopic methods increasingly overestimated the true bacterial abundance (range, 15.0 to 99.3%). The solid-phase cytometer only slightly overestimated the true bacterial abundances and was more consistent over the same range of bacterial abundances per filter (range, 8.9 to 12.5%). The solid-phase cytometer method for conducting total direct counts of bacteria was less biased and performed significantly better than any of the microscope methods. It was also found that microscopic count data from counting 5 fields on three separate filters were statistically equivalent to data from counting 20 fields on a single filter.

  12. Hop limited epidemic-like information spreading in mobile social networks with selfish nodes

    NASA Astrophysics Data System (ADS)

    Wu, Yahui; Deng, Su; Huang, Hongbin

    2013-07-01

    Similar to epidemics, information can be transmitted directly among users in mobile social networks. Different from epidemics, we can control the spreading process by adjusting the corresponding parameters (e.g., hop count) directly. This paper proposes a theoretical model to evaluate the performance of an epidemic-like spreading algorithm, in which the maximal hop count of the information is limited. In addition, our model can be used to evaluate the impact of users’ selfish behavior. Simulations show the accuracy of our theoretical model. Numerical results show that the information hop count can have an important impact. In addition, the impact of selfish behavior is related to the information hop count.

  13. High resolution biomedical imaging system with direct detection of x-rays via a charge coupled device

    DOEpatents

    Atac, M.; McKay, T.A.

    1998-04-21

    An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD. 13 figs.

  14. High resolution biomedical imaging system with direct detection of x-rays via a charge coupled device

    DOEpatents

    Atac, Muzaffer; McKay, Timothy A.

    1998-01-01

    An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD.

  15. Formation and resuscitation of viable but nonculturable Salmonella typhi.

    PubMed

    Zeng, Bin; Zhao, Guozhong; Cao, Xiaohong; Yang, Zhen; Wang, Chunling; Hou, Lihua

    2013-01-01

    Salmonella typhi is a pathogen that causes the human disease of typhoid fever. The aim of this study was to investigate the viable but nonculturable (VBNC) state of S. typhi. Some samples were stimulated at 4°C or -20°C, while others were induced by different concentrations of CuSO4. Total cell counts remained constant throughout several days by acridine orange direct counting; however, plate counts declined to undetectable levels within 48 hours by plate counting at -20°C. The direct viable counts remained fairly constant at this level by direct viable counting. Carbon and nitrogen materials slowly decreased which indicated that a large population of cells existed in the VBNC state and entered the VBNC state in response to exposure to 0.01 or 0.015 mmol/L CuSO4 for more than 14 or 12 days, respectively. Adding 3% Tween 20 or 1% catalase enabled cells to become culturable again, with resuscitation times of 48 h and 24 h, respectively. The atomic force microscope results showed that cells gradually changed in shape from short rods to coccoids, and decreased in size when they entered the VBNC state. Further animal experiments suggested that resuscitated cells might regain pathogenicity.

  16. Rapid Membrane Filtration-Epifluorescent Microscopy Technique for Direct Enumeration of Bacteria in Raw Milk

    PubMed Central

    Pettipher, Graham L.; Mansell, Roderick; McKinnon, Charles H.; Cousins, Christina M.

    1980-01-01

    Membrane filtration and epifluorescent microscopy were used for the direct enumeration of bacteria in raw milk. Somatic cells were lysed by treatment with trypsin and Triton X-100 so that 2 ml of milk containing up to 5 × 106 somatic cells/ml could be filtered. The majority of the bacteria (ca. 80%) remained intact and were concentrated on the membrane. After being stained with acridine organe, the bacteria fluoresced under ultraviolet light and could easily be counted. The clump count of orange fluorescing cells on the membrane correlated well (r = 0.91) with the corresponding plate count for farm, tanker, and silo milks. Differences between counts obtained by different operators and between the membrane clump count and plate count were not significant. The technique is rapid, taking less than 25 min, inexpensive, costing less than 50 cents per sample, and is suitable for milks containing 5 × 103 to 5 × 108 bacteria per ml. Images PMID:16345515

  17. Direct reconstruction of parametric images for brain PET with event-by-event motion correction: evaluation in two tracers across count levels

    NASA Astrophysics Data System (ADS)

    Germino, Mary; Gallezot, Jean-Dominque; Yan, Jianhua; Carson, Richard E.

    2017-07-01

    Parametric images for dynamic positron emission tomography (PET) are typically generated by an indirect method, i.e. reconstructing a time series of emission images, then fitting a kinetic model to each voxel time activity curve. Alternatively, ‘direct reconstruction’, incorporates the kinetic model into the reconstruction algorithm itself, directly producing parametric images from projection data. Direct reconstruction has been shown to achieve parametric images with lower standard error than the indirect method. Here, we present direct reconstruction for brain PET using event-by-event motion correction of list-mode data, applied to two tracers. Event-by-event motion correction was implemented for direct reconstruction in the Parametric Motion-compensation OSEM List-mode Algorithm for Resolution-recovery reconstruction. The direct implementation was tested on simulated and human datasets with tracers [11C]AFM (serotonin transporter) and [11C]UCB-J (synaptic density), which follow the 1-tissue compartment model. Rigid head motion was tracked with the Vicra system. Parametric images of K 1 and distribution volume (V T  =  K 1/k 2) were compared to those generated by the indirect method by regional coefficient of variation (CoV). Performance across count levels was assessed using sub-sampled datasets. For simulated and real datasets at high counts, the two methods estimated K 1 and V T with comparable accuracy. At lower count levels, the direct method was substantially more robust to outliers than the indirect method. Compared to the indirect method, direct reconstruction reduced regional K 1 CoV by 35-48% (simulated dataset), 39-43% ([11C]AFM dataset) and 30-36% ([11C]UCB-J dataset) across count levels (averaged over regions at matched iteration); V T CoV was reduced by 51-58%, 54-60% and 30-46%, respectively. Motion correction played an important role in the dataset with larger motion: correction increased regional V T by 51% on average in the [11C]UCB-J dataset. Direct reconstruction of dynamic brain PET with event-by-event motion correction is achievable and dramatically more robust to noise in V T images than the indirect method.

  18. Coming to an Understanding of the Signed Numbers: How Second and Third Grade Students Make Sense of the Integers

    ERIC Educational Resources Information Center

    Madsen, Mark S.

    2010-01-01

    The purpose of this research has been to generate learning environments that surrounded second and third grade students with bi-directional counting experiences, leading them to discover and come to an understanding of opposite numbers. While engaged in games and bi-directional activities, these young students eagerly counted, by jumping frogs…

  19. The clinical significance of platelet counts in the first 24 hours after severe injury.

    PubMed

    Stansbury, Lynn G; Hess, Aaron S; Thompson, Kwaku; Kramer, Betsy; Scalea, Thomas M; Hess, John R

    2013-04-01

    Admission platelet (PLT) counts are known to be associated with all-cause mortality for seriously injured patients admitted to a trauma center. The course of subsequent PLT counts, their implications, and the effects of PLT therapy are less well known. Trauma center patients who were directly admitted from the scene of injury, received 1 or more units of uncrossmatched red blood cells in the first hour of care, survived for at least 15 minutes, and had a PLT count measured in the first hour were analyzed for the association of their admission and subsequent PLT counts in the first 24 hours with injury severity and hemorrhagic and central nervous system (CNS) causes of in-hospital mortality. Over an 8.25-year period, 1292 of 45,849 direct trauma admissions met entry criteria. Admission PLT counts averaged 228×10(9) ±90×10(9) /L and decreased by 104×10(9) /L by the second hour and 1×10(9) /L each hour thereafter. The admission count was not related to time to admission. Each 1-point increase in the injury severity score was associated with a 1×10(9) /L decrease in the PLT count at all times in the first 24 hours of care. Admission PLT counts were strongly associated with hemorrhagic and CNS injury mortality and subsequent PLT counts. Effects of PLT therapy could not be ascertained. Admission PLT counts in critically injured trauma patients are usually normal, decreasing after admission. Low PLT counts at admission and during the course of trauma care are strongly associated with mortality. © 2012 American Association of Blood Banks.

  20. Dynamic pulse difference circuit

    DOEpatents

    Erickson, Gerald L.

    1978-01-01

    A digital electronic circuit of especial use for subtracting background activity pulses in gamma spectrometry comprises an up-down counter connected to count up with signal-channel pulses and to count down with background-channel pulses. A detector responsive to the count position of the up-down counter provides a signal when the up-down counter has completed one scaling sequence cycle of counts in the up direction. In an alternate embodiment, a detector responsive to the count position of the up-down counter provides a signal upon overflow of the counter.

  1. Immune hemolytic anemia

    MedlinePlus

    ... Absolute reticulocyte count Direct or indirect Coombs test Hemoglobin in the urine LDH (level of this enzyme ... of tissue damage) Red blood cell count (RBC), hemoglobin, and hematocrit Serum bilirubin level Serum free hemoglobin ...

  2. Statistical study of muons counts rates in differents directions, observed at the Brazilian Southern Space Observatory

    NASA Astrophysics Data System (ADS)

    Grams, Guilherme; Schuch, Nelson Jorge; Braga, Carlos Roberto; Purushottam Kane, Rajaram; Echer, Ezequiel; Ronan Coelho Stekel, Tardelli

    Cosmic ray are charged particles, at the most time protons, that reach the earth's magne-tosphere from interplanetary space with velocities greater than the solar wind. When these impinge the atmosphere, they interact with atmosphere constituents and decay into sub-particles forming an atmospheric shower. The muons are the sub-particles which normally maintain the originated direction of the primary cosmic ray. A multi-directional muon detec-tor (MMD) was installed in 2001 and upgraded in 2005, through an international cooperation between Brazil, Japan and USA, and operated since then at the Southern Space Observatory -SSO/CRS/CCR/INPE -MCT, (29,4° S, 53,8° W, 480m a.s.l.), São Martinho da Serra, RS, a Brazil. The main objetive of this work is to present a statistical analysis of the intensity of muons, with energy between 50 and 170 GeV, in differents directions, measured by the SSO's multi-directional muon detector. The analysis was performed with data from 2006 and 2007 collected by the SSO's MMD. The MMD consists of two layers of 4x7 detectors with a total observation area of 28 m2 . The counting of muons in each directional channel is made by a coincidence of pulses pair, one from a detector in the upper layer and the other from a detector in the lower layer. The SSO's MMD is equipped with 119 directional channels for muon count rate measurement and is capable of detecting muons incident with zenithal angle between 0° and 75,53° . A statistical analysis was made with the MMD muon count rate for all the di-rectional channels. The average and the standard deviation of the muon count rate in each directional component were calculated. The results show lower cont rate for the channels with larger zenith, and higher cont rate with smaller zenith, as expected from the production and propagation of muons in the atmosphere. It is also possible to identify the Stormer cone. The SSO's MMD is also a detector component of the Global Muon Detector Network (GMDN), which has been developed in an international collaboration lead by Shinshu University, Japan.

  3. An evaluation of the utility and limitations of counting motor unit action potentials in the surface electromyogram

    NASA Astrophysics Data System (ADS)

    Zhou, Ping; Zev Rymer, William

    2004-12-01

    The number of motor unit action potentials (MUAPs) appearing in the surface electromyogram (EMG) signal is directly related to motor unit recruitment and firing rates and therefore offers potentially valuable information about the level of activation of the motoneuron pool. In this paper, based on morphological features of the surface MUAPs, we try to estimate the number of MUAPs present in the surface EMG by counting the negative peaks in the signal. Several signal processing procedures are applied to the surface EMG to facilitate this peak counting process. The MUAP number estimation performance by this approach is first illustrated using the surface EMG simulations. Then, by evaluating the peak counting results from the EMG records detected by a very selective surface electrode, at different contraction levels of the first dorsal interosseous (FDI) muscles, the utility and limitations of such direct peak counts for MUAP number estimation in surface EMG are further explored.

  4. Matching the Statistical Model to the Research Question for Dental Caries Indices with Many Zero Counts.

    PubMed

    Preisser, John S; Long, D Leann; Stamm, John W

    2017-01-01

    Marginalized zero-inflated count regression models have recently been introduced for the statistical analysis of dental caries indices and other zero-inflated count data as alternatives to traditional zero-inflated and hurdle models. Unlike the standard approaches, the marginalized models directly estimate overall exposure or treatment effects by relating covariates to the marginal mean count. This article discusses model interpretation and model class choice according to the research question being addressed in caries research. Two data sets, one consisting of fictional dmft counts in 2 groups and the other on DMFS among schoolchildren from a randomized clinical trial comparing 3 toothpaste formulations to prevent incident dental caries, are analyzed with negative binomial hurdle, zero-inflated negative binomial, and marginalized zero-inflated negative binomial models. In the first example, estimates of treatment effects vary according to the type of incidence rate ratio (IRR) estimated by the model. Estimates of IRRs in the analysis of the randomized clinical trial were similar despite their distinctive interpretations. The choice of statistical model class should match the study's purpose, while accounting for the broad decline in children's caries experience, such that dmft and DMFS indices more frequently generate zero counts. Marginalized (marginal mean) models for zero-inflated count data should be considered for direct assessment of exposure effects on the marginal mean dental caries count in the presence of high frequencies of zero counts. © 2017 S. Karger AG, Basel.

  5. Matching the Statistical Model to the Research Question for Dental Caries Indices with Many Zero Counts

    PubMed Central

    Preisser, John S.; Long, D. Leann; Stamm, John W.

    2017-01-01

    Marginalized zero-inflated count regression models have recently been introduced for the statistical analysis of dental caries indices and other zero-inflated count data as alternatives to traditional zero-inflated and hurdle models. Unlike the standard approaches, the marginalized models directly estimate overall exposure or treatment effects by relating covariates to the marginal mean count. This article discusses model interpretation and model class choice according to the research question being addressed in caries research. Two datasets, one consisting of fictional dmft counts in two groups and the other on DMFS among schoolchildren from a randomized clinical trial (RCT) comparing three toothpaste formulations to prevent incident dental caries, are analysed with negative binomial hurdle (NBH), zero-inflated negative binomial (ZINB), and marginalized zero-inflated negative binomial (MZINB) models. In the first example, estimates of treatment effects vary according to the type of incidence rate ratio (IRR) estimated by the model. Estimates of IRRs in the analysis of the RCT were similar despite their distinctive interpretations. Choice of statistical model class should match the study’s purpose, while accounting for the broad decline in children’s caries experience, such that dmft and DMFS indices more frequently generate zero counts. Marginalized (marginal mean) models for zero-inflated count data should be considered for direct assessment of exposure effects on the marginal mean dental caries count in the presence of high frequencies of zero counts. PMID:28291962

  6. Automatic, time-interval traffic counts for recreation area management planning

    Treesearch

    D. L. Erickson; C. J. Liu; H. K. Cordell

    1980-01-01

    Automatic, time-interval recorders were used to count directional vehicular traffic on a multiple entry/exit road network in the Red River Gorge Geological Area, Daniel Boone National Forest. Hourly counts of entering and exiting traffic differed according to recorder location, but an aggregated distribution showed a delayed peak in exiting traffic thought to be...

  7. Comparison study of membrane filtration direct count and an automated coliform and Escherichia coli detection system for on-site water quality testing.

    PubMed

    Habash, Marc; Johns, Robert

    2009-10-01

    This study compared an automated Escherichia coli and coliform detection system with the membrane filtration direct count technique for water testing. The automated instrument performed equal to or better than the membrane filtration test in analyzing E. coli-spiked samples and blind samples with interference from Proteus vulgaris or Aeromonas hydrophila.

  8. Measuring Transmission Efficiencies Of Mass Spectrometers

    NASA Technical Reports Server (NTRS)

    Srivastava, Santosh K.

    1989-01-01

    Coincidence counts yield absolute efficiencies. System measures mass-dependent transmission efficiencies of mass spectrometers, using coincidence-counting techniques reminiscent of those used for many years in calibration of detectors for subatomic particles. Coincidences between detected ions and electrons producing them counted during operation of mass spectrometer. Under certain assumptions regarding inelastic scattering of electrons, electron/ion-coincidence count is direct measure of transmission efficiency of spectrometer. When fully developed, system compact, portable, and used routinely to calibrate mass spectrometers.

  9. DIRECT COUPLED PROGRESSIVE STAGE PULSE COUNTER APPARATUS

    DOEpatents

    Kaufman, W.M.

    1962-08-14

    A progressive electrical pulse counter circuit was designed for the counting of a chain of input pulses of random width and/or frequency. The circuit employs an odd and even pulse input line alternately connected to a series of directly connected bistable counting stages. Each bistable stage has two d-c operative states which stage, when in its rnrtial state, prevents the next succeeding stage from changing its condition when the latter stage is pulsed. Since only altennate stages are pulsed for each incoming pulse, only one stage will change its state for each input pulse thereby providing prog essive stage by stage counting. (AEC)

  10. Avian leucocyte counting using the hemocytometer

    USGS Publications Warehouse

    Dein, F.J.; Wilson, A.; Fischer, D.; Langenberg, P.

    1994-01-01

    Automated methods for counting leucocytes in avian blood are not available because of the presence of nucleated erythrocytes and thrombocytes. Therefore, total white blood cell counts are performed by hand using a hemocytometer. The Natt and Herrick and the Unopette methods are the most common stain and diluent preparations for this procedure. Replicate hemocytometer counts using these two methods were performed on blood from four birds of different species. Cells present in each square of the hemocytometer were counted. Counting cells in the corner, side, or center hemocytometer squares produced statistically equivalent results; counting four squares per chamber provided a result similar to that obtained by counting nine squares; and the Unopette method was more precise for hemocytometer counting than was the Natt and Herrick method. The Unopette method is easier to learn and perform but is an indirect process, utilizing the differential count from a stained smear. The Natt and Herrick method is a direct total count, but cell identification is more difficult.

  11. Transition Years Count: An Adolescent Profile. KIDS COUNT County Data Book, 1999.

    ERIC Educational Resources Information Center

    Kentucky Youth Advocates, Inc., Louisville.

    This Kids Count data book is the ninth to examine trends in the well-being of Kentucky children, focusing on the transition period of adolescence, based on the view that lessons learned and foundations laid in early adolescence directly impact the transition to adulthood. This statistical portrait is based on trends in indicators of well-being in…

  12. [Factors affecting the DAPI fluorescence direct count in the tidal river sediment].

    PubMed

    Chen, Chen; Huang, Shan; Wu, Qun-he; Li, Rui-yi; Zhang, Ren-duo

    2010-08-01

    The factors affecting the DAPI (4', 6-diamidino-2-phenylidole) fluorescence direct count in the tidal river sediment were examined. Sediment samples were collected from the Guangzhou section of the Pearl River. Besides sediment texture and organic matter, an improved staining procedure and the involved parameters were analyzed. Results showed that the procedure with the sediment with 2000 fold dilution and ultrasonic water bath for 10 min, and with a final DAPI concentration of 10 microg x mL(-1) and staining time for more than 30 min produced the optimum results of DAPI direct count in the sediment. The total bacterial number was correlated to the proportion of the non-nucleoid-containing cells to the total bacterial number (r = 0.587, p = 0.004). The organic matter content also correlated to the ration. The clay content had a strong correlation with the organic matter, through which the clay content also affected the ratio. A multiple regression analysis between the ration versus the organic matter, the total bacterial number, and the clay content showed that the regression equation fit the measure values satisfactorily (r = 0.694). These results indicated that the above factors needed to be considered in the applications of the DAPI fluorescence direct counting method to the tidal river sediment.

  13. Genotype x environment interactions in milk yield and quality in Angus, Brahman, and reciprocal-cross cows on different forage systems.

    PubMed

    Brown, M A; Brown, A H; Jackson, W G; Miesner, J R

    2001-07-01

    Milk yield and quality were observed on 93 Angus, Brahman, and reciprocal-cross cows over 3 yr to evaluate the interactions of direct and maternal breed effects and heterosis with forage environment. Forage environments were common bermudagrass (BG), endophyte-infected tall fescue (E+), and a rotational system (ROT) of both forages, in which each forage (BG or E+) was grazed during its appropriate season, usually June through October for BG and November through May for E+. Milk yield was estimated each of 6 mo (April through September) via milking machine and converted to a 24-h basis. Milk fat, milk protein, and somatic cell count were analyzed by a commercial laboratory. Heterosis for milk yield was similar among forages, averaging 2.4 kg (P < 0.01). Expressed as percentages of purebred means, heterosis for milk yield was largest on E+ (52.8%), intermediate on ROT (39.3%), and smallest on BG (23.7%). Direct breed effects for milk yield favored Brahman, and they were similar among forages but tended to be larger for E+ (2.5 kg) and ROT (2.8 kg) than for BG (1.3 kg). Direct breed effects for milk fat favored Brahman and were similar among forages but tended to be larger for E+ (1.0%) and ROT (1.0%) than for BG (0.6%). Purebred cows exceeded crossbreds in milk protein by 0.1% on ROT (P < 0.10). Crossbred cows had lower somatic cell counts than purebreds on BG (P < 0.05), E+ (P < 0.01), or ROT (P > 0.30). Heterosis for somatic cell counts as percentages of purebred means was similar for BG (-68.3%) and E+ (-68.9%) and less favorable for ROT (-31.6%). Maternal breed effects for somatic cell count favored Angus on ROT (P < 0.10) with a similar nonsignificant trend on BG and E+. Direct breed effects for somatic cell count favored Brahman on ROT (P < 0.10) with similar nonsignificant trends on BG and E+. These results suggested that a rotation of cows from E+ to BG in the summer can partially alleviate negative effects of E+ on milk yield. Conclusions also indicated an advantage to crossbred cows in somatic cell count and provided evidence of both direct and maternal breed effects for this trait. The results also suggested that direct breed effects for milk yield, milk fat, and somatic cell count and heterosis for milk yield and somatic cell count (as percentages of purebred means) tended to vary with forage environment, indicating a potential for genotype x environment interaction for these traits.

  14. Array-based infra-red detection: an enabling technology for people counting, sensing, tracking, and intelligent detection

    NASA Astrophysics Data System (ADS)

    Stogdale, Nick; Hollock, Steve; Johnson, Neil; Sumpter, Neil

    2003-09-01

    A 16x16 element un-cooled pyroelectric detector array has been developed which, when allied with advanced tracking and detection algorithms, has created a universal detector with multiple applications. Low-cost manufacturing techniques are used to fabricate a hybrid detector, intended for economic use in commercial markets. The detector has found extensive application in accurate people counting, detection, tracking, secure area protection, directional sensing and area violation; topics which are all pertinent to the provision of Homeland Security. The detection and tracking algorithms have, when allied with interpolation techniques, allowed a performance much higher than might be expected from a 16x16 array. This paper reviews the technology, with particular attention to the array structure, algorithms and interpolation techniques and outlines its application in a number of challenging market areas. Viewed from above, moving people are seen as 'hot blobs' moving through the field of view of the detector; background clutter or stationary objects are not seen and the detector works irrespective of lighting or environmental conditions. Advanced algorithms detect the people and extract size, shape, direction and velocity vectors allowing the number of people to be detected and their trajectories of motion to be tracked. Provision of virtual lines in the scene allows bi-directional counting of people flowing in and out of an entrance or area. Definition of a virtual closed area in the scene allows counting of the presence of stationary people within a defined area. Definition of 'counting lines' allows the counting of people, the ability to augment access control devices by confirming a 'one swipe one entry' judgement and analysis of the flow and destination of moving people. For example, passing the 'wrong way' up a denied passageway can be detected. Counting stationary people within a 'defined area' allows the behaviour and size of groups of stationary people to be analysed and counted, an alarm condition can also be generated when people stray into such areas.

  15. Background compensation for a radiation level monitor

    DOEpatents

    Keefe, D.J.

    1975-12-01

    Background compensation in a device such as a hand and foot monitor is provided by digital means using a scaler. With no radiation level test initiated, a scaler is down-counted from zero according to the background measured. With a radiation level test initiated, the scaler is up-counted from the previous down-count position according to the radiation emitted from the monitored object and an alarm is generated if, with the scaler having crossed zero in the positive going direction, a particular number is exceeded in a specific time period after initiation of the test. If the test is initiated while the scale is down-counting, the background count from the previous down- count stored in a memory is used as the initial starting point for the up-count.

  16. A novel concentration and viability detection method for Brettanomyces using the Cellometer image cytometry.

    PubMed

    Martyniak, Brian; Bolton, Jason; Kuksin, Dmitry; Shahin, Suzanne M; Chan, Leo Li-Ying

    2017-01-01

    Brettanomyces spp. can present unique cell morphologies comprised of excessive pseudohyphae and budding, leading to difficulties in enumerating cells. The current cell counting methods include manual counting of methylene blue-stained yeasts or measuring optical densities using a spectrophotometer. However, manual counting can be time-consuming and has high operator-dependent variations due to subjectivity. Optical density measurement can also introduce uncertainties where instead of individual cells counted, an average of a cell population is measured. In contrast, by utilizing the fluorescence capability of an image cytometer to detect acridine orange and propidium iodide viability dyes, individual cell nuclei can be counted directly in the pseudohyphae chains, which can improve the accuracy and efficiency of cell counting, as well as eliminating the subjectivity from manual counting. In this work, two experiments were performed to demonstrate the capability of Cellometer image cytometer to monitor Brettanomyces concentrations, viabilities, and budding/pseudohyphae percentages. First, a yeast propagation experiment was conducted to optimize software counting parameters for monitoring the growth of Brettanomyces clausenii, Brettanomyces bruxellensis, and Brettanomyces lambicus, which showed increasing cell concentrations, and varying pseudohyphae percentages. The pseudohyphae formed during propagation were counted either as multiple nuclei or a single multi-nuclei organism, where the results of counting the yeast as a single multi-nuclei organism were directly compared to manual counting. Second, a yeast fermentation experiment was conducted to demonstrate that the proposed image cytometric analysis method can monitor the growth pattern of B. lambicus and B. clausenii during beer fermentation. The results from both experiments displayed different growth patterns, viability, and budding/pseudohyphae percentages for each Brettanomyces species. The proposed Cellometer image cytometry method can improve efficiency and eliminate operator-dependent variations of cell counting compared with the traditional methods, which can potentially improve the quality of beverage products employing Brettanomyces yeasts.

  17. Transport of airborne pollen into the city of Thessaloniki: the effects of wind direction, speed and persistence

    NASA Astrophysics Data System (ADS)

    Damialis, Athanasios; Gioulekas, Dimitrios; Lazopoulou, Chariklia; Balafoutis, Christos; Vokou, Despina

    2005-01-01

    We examined the effect of the wind vector analyzed into its three components (direction, speed and persistence), on the circulation of pollen from differe nt plant taxa prominent in the Thessaloniki area for a 4-year period (1996- 1999). These plant taxa were Ambrosia spp., Artemisia spp., Chenopodiaceae, spp., Cupressaceae, Olea europaea, Pinaceae, Platanus spp., Poaceae, Populus spp., Quercus spp., and Urticaceae. Airborne pollen of Cupressaceae, Urticaceae, Quercus spp. and O. europaea make up approximately 70% of the total average annual pollen counts. The set of data that we worked with represented days without precipitation and time intervals during which winds blew from the same direction for at least 4 consecutive hours. We did this in order to study the effect of the different wind components independently of precipitation, and to avoid secondary effects produced by pollen resuspension phenomena. Factorial regression analysis among the summed bi-hourly pollen counts for each taxon and the values of wind speed and persistence per wind direction gave significant results in 22 cases (combinations of plant taxa and wind directions). The pollen concentrations of all taxa correlated significantly with at least one of the three wind components. In seven out of the 22 taxon-wind direction combinations, the pollen counts correlated positively with wind persistence, whereas this was the case for only two of the taxon-wind speed combinations. In seven cases, pollen counts correlated with the interaction effect of wind speed and persistence. This shows the importance of wind persistence in pollen transport, particularly when weak winds prevail for a considerable part of the year, as is the case for Thessaloniki. Medium/long-distance pollen transport was evidenced for Olea (NW, SW directions), Corylus (NW, SW), Poaceae (SW) and Populus (NW).

  18. Digital rotation measurement unit

    DOEpatents

    Sanderson, S.N.

    1983-09-30

    A digital rotation indicator is disclosed for monitoring the position of a valve member having a movable actuator. The indicator utilizes mercury switches adapted to move in cooperation with the actuator. Each of the switches produces an output as it changes state when the actuator moves. A direction detection circuit is connected to the switches to produce a first digital signal indicative of the direction of rotation of the actuator. A count pulse generating circuit is also connected to the switches to produce a second digital pulse signal having count pulses corresponding to a change of state of any of the mercury switches. A reset pulse generating circuit is provided to generate a reset pulse each time a count pulse is generated. An up/down counter is connected to receive the first digital pulse signal and the second digital pulse signal and to count the pulses of the second digital pulse signal either up or down depending upon the instantaneous digital value of the first digital signal whereby a running count indicative of the movement of the actuator is maintained.

  19. An Evaluation of the Accuracy of the Subtraction Method Used for Determining Platelet Counts in Advanced Platelet-Rich Fibrin and Concentrated Growth Factor Preparations

    PubMed Central

    Watanabe, Taisuke; Isobe, Kazushige; Suzuki, Taiji; Kawabata, Hideo; Nakamura, Masayuki; Tsukioka, Tsuneyuki; Okudera, Toshimitsu; Okudera, Hajime; Uematsu, Kohya; Okuda, Kazuhiro; Nakata, Koh; Kawase, Tomoyuki

    2017-01-01

    Platelet concentrates should be quality-assured of purity and identity prior to clinical use. Unlike for the liquid form of platelet-rich plasma, platelet counts cannot be directly determined in solid fibrin clots and are instead calculated by subtracting the counts in other liquid or semi-clotted fractions from those in whole blood samples. Having long suspected the validity of this method, we herein examined the possible loss of platelets in the preparation process. Blood samples collected from healthy male donors were immediately centrifuged for advanced platelet-rich fibrin (A-PRF) and concentrated growth factors (CGF) according to recommended centrifugal protocols. Blood cells in liquid and semi-clotted fractions were directly counted. Platelets aggregated on clot surfaces were observed by scanning electron microscopy. A higher centrifugal force increased the numbers of platelets and platelet aggregates in the liquid red blood cell fraction and the semi-clotted red thrombus in the presence and absence of the anticoagulant, respectively. Nevertheless, the calculated platelet counts in A-PRF/CGF preparations were much higher than expected, rendering the currently accepted subtraction method inaccurate for determining platelet counts in fibrin clots. To ensure the quality of solid types of platelet concentrates chairside in a timely manner, a simple and accurate platelet-counting method should be developed immediately. PMID:29563413

  20. Low-dose electron energy-loss spectroscopy using electron counting direct detectors.

    PubMed

    Maigné, Alan; Wolf, Matthias

    2018-03-01

    Since the development of parallel electron energy loss spectroscopy (EELS), charge-coupled devices (CCDs) have been the default detectors for EELS. With the recent development of electron-counting direct-detection cameras, micrographs can be acquired under very low electron doses at significantly improved signal-to-noise ratio. In spectroscopy, in particular in combination with a monochromator, the signal can be extremely weak and the detection limit is principally defined by noise introduced by the detector. Here we report the use of an electron-counting direct-detection camera for EEL spectroscopy. We studied the oxygen K edge of amorphous ice and obtained a signal noise ratio up to 10 times higher than with a conventional CCD.We report the application of electron counting to record time-resolved EEL spectra of a biological protein embedded in amorphous ice, revealing chemical changes observed in situ while exposed by the electron beam. A change in the fine structure of nitrogen K and the carbon K edges were recorded during irradiation. A concentration of 3 at% nitrogen was detected with a total electron dose of only 1.7 e-/Å2, extending the boundaries of EELS signal detection at low electron doses.

  1. SCATHA-Analysis System

    DTIC Science & Technology

    1981-01-31

    geometric factor. For the low energy FSA detectors, the background counts must be subtracted from the measured (actual) counts before the geometric factor...and high energy) each provide a background measure - ment. The background counts for the low energy ESA (LE ESA) were subtracted from the other four LE...perpendicular to the spacecraft +X reference spin axis and 189.660 around from the +Z axis (with this angle measured from the +Z axis in the direction

  2. 45 CFR 261.31 - How many hours must a work-eligible individual participate for the family to count in the...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... three activities may also count as participation: job skills training directly related to employment... study leading to a certificate of general equivalence. (d)(1) We will deem a work-eligible individual...

  3. Radionuclide counting technique for measuring wind velocity and direction

    NASA Technical Reports Server (NTRS)

    Singh, J. J. (Inventor)

    1984-01-01

    An anemometer utilizing a radionuclide counting technique for measuring both the velocity and the direction of wind is described. A pendulum consisting of a wire and a ball with a source of radiation on the lower surface of the ball is positioned by the wind. Detectors and are located in a plane perpendicular to pendulum (no wind). The detectors are located on the circumferene of a circle and are equidistant from each other as well as the undisturbed (no wind) source ball position.

  4. Spacecraft with gradual acceleration of solar panels

    NASA Technical Reports Server (NTRS)

    Merhav, Tamir R. (Inventor); Festa, Michael T. (Inventor); Stetson, Jr., John B. (Inventor)

    1996-01-01

    A spacecraft (8) includes a movable appendage such as solar panels (12) operated by a stepping motor (28) driven by pulses (311). In order to reduce vibration andor attitude error, the drive pulses are generated by a clock down-counter (312) with variable count ratio. Predetermined desired clock ratios are stored in selectable memories (314a-d), and the selected ratio (R) is coupled to a comparator (330) together with the current ratio (C). An up-down counter (340) establishes the current count-down ratio by counting toward the desired ratio under the control of the comparator; thus, a step change of solar panel speed never occurs. When a direction change is commanded, a flag signal generator (350) disables the selectable memories, and enables a further store (360), which generates a count ratio representing a very slow solar panel rotational rate, so that the rotational rate always slows to a low value before direction is changed. The principles of the invention are applicable to any movable appendage.

  5. 4D light-field sensing system for people counting

    NASA Astrophysics Data System (ADS)

    Hou, Guangqi; Zhang, Chi; Wang, Yunlong; Sun, Zhenan

    2016-03-01

    Counting the number of people is still an important task in social security applications, and a few methods based on video surveillance have been proposed in recent years. In this paper, we design a novel optical sensing system to directly acquire the depth map of the scene from one light-field camera. The light-field sensing system can count the number of people crossing the passageway, and record the direction and intensity of rays at a snapshot without any assistant light devices. Depth maps are extracted from the raw light-ray sensing data. Our smart sensing system is equipped with a passive imaging sensor, which is able to naturally discern the depth difference between the head and shoulders for each person. Then a human model is built. Through detecting the human model from light-field images, the number of people passing the scene can be counted rapidly. We verify the feasibility of the sensing system as well as the accuracy by capturing real-world scenes passing single and multiple people under natural illumination.

  6. Far-Ultraviolet Number Counts of Field Galaxies

    NASA Technical Reports Server (NTRS)

    Voyer, Elysse N.; Gardner, Jonathan P.; Teplitz, Harry I.; Siana, Brian D.; deMello, Duilia F.

    2010-01-01

    The Number counts of far-ultraviolet (FUV) galaxies as a function of magnitude provide a direct statistical measure of the density and evolution of star-forming galaxies. We report on the results of measurements of the rest-frame FUV number counts computed from data of several fields including the Hubble Ultra Deep Field, the Hubble Deep Field North, and the GOODS-North and -South fields. These data were obtained from the Hubble Space Telescope Solar Blind Channel of the Advance Camera for Surveys. The number counts cover an AB magnitude range from 20-29 magnitudes, covering a total area of 15.9 arcmin'. We show that the number counts are lower than those in previous studies using smaller areas. The differences in the counts are likely the result of cosmic variance; our new data cover more area and more lines of sight than the previous studies. The slope of our number counts connects well with local FUV counts and they show good agreement with recent semi-analytical models based on dark matter "merger trees".

  7. Genetic parameters for fecal egg count and body weight in Katahdin lambs

    USDA-ARS?s Scientific Manuscript database

    The objective of this study was to estimate genetic parameters for fecal egg count at weaning (WFEC) and post weaning (PWFEC), and weights at birth (BW), weaning (WW) and post weaning (PWW) in Katahdin lambs by investigating direct additive, maternal additive, maternal permanent environmental and ma...

  8. 77 FR 73557 - Airworthiness Directives; Turbomeca S.A. Turboshaft Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-12-11

    ... turboshaft engines. This proposed AD was prompted by a finding that the engine's tachometer unit cycle... tachometer's unit cycle counting feature. This proposed AD would also require ground-run functional checks... accuracy of the engine's tachometer cycle counting feature. We are proposing this AD to prevent uncontained...

  9. Temporal Association Between Nonfatal Self-Directed Violence and Tree and Grass Pollen Counts.

    PubMed

    Jeon-Slaughter, Haekyung; Claassen, Cynthia A; Khan, David A; Mihalakos, Perry; Lee, Kevin B; Brown, E Sherwood

    2016-09-01

    Prior research suggests a possible association between pollen and suicide. No studies have examined the relationship between pollen and attempted suicide. This study examines the temporal association between airborne pollen counts and nonfatal suicidal and nonsuicidal self-directed violence (SDV) requiring an emergency department visit. Data on daily emergency department visits due to nonfatal SDV as identified by ICD-9 diagnosis criteria were extracted from emergency department medical records of Parkland Memorial Hospital in Dallas, Texas, between January 2000 and December 2003. Concurrent daily airborne tree, grass, and ragweed pollen data from the city of Dallas were extracted from the National Allergy Bureau online database. The data were analyzed using the time series method of generalized autoregressive conditional heteroskedasticity. There were statistically significant and positive temporal associations between tree pollen counts and the number of nonfatal SDV events among women (P = .04) and between grass pollen counts and number of nonfatal SDV events among both men (P = .03) and women (P < .0001). There was no significant temporal association found between ragweed pollen counts and number of nonfatal SDV events. The study findings suggest that an increase in nonfatal SDV is associated with changes in tree and grass pollen counts. This is the first study that has examined an association between seasonal variation in tree and grass pollen levels and nonfatal SDV event data. The study also used a narrowly defined geographic area and temporal window. The findings suggest that pollen count may be a factor influencing seasonal patterns in suicidal behavior. © Copyright 2016 Physicians Postgraduate Press, Inc.

  10. Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting.

    PubMed

    Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay

    2016-04-09

    Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e(-) read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor.

  11. High throughput single cell counting in droplet-based microfluidics.

    PubMed

    Lu, Heng; Caen, Ouriel; Vrignon, Jeremy; Zonta, Eleonora; El Harrak, Zakaria; Nizard, Philippe; Baret, Jean-Christophe; Taly, Valérie

    2017-05-02

    Droplet-based microfluidics is extensively and increasingly used for high-throughput single-cell studies. However, the accuracy of the cell counting method directly impacts the robustness of such studies. We describe here a simple and precise method to accurately count a large number of adherent and non-adherent human cells as well as bacteria. Our microfluidic hemocytometer provides statistically relevant data on large populations of cells at a high-throughput, used to characterize cell encapsulation and cell viability during incubation in droplets.

  12. A Comparison of the OSHA Modified NIOSH Physical and Chemical Analytical Method (P and CAM) 304 and the Dust Trak Photometric Aerosol Sampler for 0-Chlorobenzylidine Malonitrile

    DTIC Science & Technology

    2013-04-02

    photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method to determine correlation between the two...study compared the non-specific, rapid photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method...mask confidence training (27) . This study will compare a direct reading, non-specific photometric particle count instrument (DustTrak TSI Model

  13. Mothers of Obese Children Use More Direct Imperatives to Restrict Eating.

    PubMed

    Pesch, Megan H; Miller, Alison L; Appugliese, Danielle P; Rosenblum, Katherine L; Lumeng, Julie C

    2018-04-01

    To examine the association of mother and child characteristics with use of direct imperatives to restrict eating. A total of 237 mother-child dyads (mean child age, 70.9 months) participated in a video-recorded, laboratory-standardized eating protocol with 2 large portions of cupcakes. Videos were reliably coded for counts of maternal direct imperatives to restrict children's eating. Anthropometrics were measured. Regression models tested the association of participant characteristics with counts of direct imperatives. Child obese weight status and maternal white non-Hispanic race/ethnicity were associated with greater levels of direct imperatives to restrict eating (p = .0001 and .0004, respectively). Mothers of obese children may be using more direct imperatives to restrict eating so as to achieve behavioral compliance to decrease their child's food intake. Future work should consider the effects direct imperatives have on children's short- and long-term eating behaviors and weight gain trajectories. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.

  14. Particle count and black carbon measurements at schools in Las Vegas, NV and in the greater Salt Lake City, UT area.

    PubMed

    Brown, Steven G; Vaughn, David L; Roberts, Paul T

    2017-11-01

    As part of two separate studies aimed to characterize ambient pollutant concentrations at schools in urban areas, we compare black carbon and particle count measurements at Adcock Elementary in Las Vegas, NV (April-June 2013), and Hunter High School in the West Valley City area of greater Salt Lake City, UT (February 2012). Both schools are in urban environments, but Adcock Elementary is next to the U.S. 95 freeway. Black carbon (BC) concentrations were 13% higher at Adcock compared to Hunter, while particle count concentrations were 60% higher. When wind speeds were low-less than 2 m/sec-both BC and particle count concentrations were significantly higher at Adcock, while concentrations at Hunter did not have as strong a variation with wind speed. When wind speeds were less than 2 m/sec, emissions from the adjacent freeway greatly affected concentrations at Adcock, regardless of wind direction. At both sites, BC and particle count concentrations peaked in the morning during commute hours. At Adcock, particle count also peaked during midday or early afternoon, when BC was low and conditions were conducive to new particle formation. While this midday peak occurred at Adcock on roughly 45% of the measured days, it occurred on only about 25% of the days at Hunter, since conditions for particle formation (higher solar radiation, lower wind speeds, lower relative humidity) were more conducive at Adcock. Thus, children attending these schools are likely to be exposed to pollution peaks during school drop-off in the morning, when BC and particle count concentrations peak, and often again during lunchtime recess when particle count peaks again. Particle count concentrations at two schools were shown to typically be independent of BC or other pollutants. At a school in close proximity to a major freeway, particle count concentrations were high during the midday and when wind speeds were low, regardless of wind direction, showing a large area of effect from roadway emissions even when the school was not downwind of the roadway. At the second school, which sits in an urban neighborhood away from freeways, high particle counts occurred even though solar radiation was low during wintertime conditions, meaning that exposure to high particle counts can occur throughout the year.

  15. Unimanual SNARC Effect: Hand Matters.

    PubMed

    Riello, Marianna; Rusconi, Elena

    2011-01-01

    A structural representation of the hand embedding information about the identity and relative position of fingers is necessary to counting routines. It may also support associations between numbers and allocentric spatial codes that predictably interact with other known numerical spatial representations, such as the mental number line (MNL). In this study, 48 Western participants whose typical counting routine proceeded from thumb-to-little on both hands performed magnitude and parity binary judgments. Response keys were pressed either with the right index and middle fingers or with the left index and middle fingers in separate blocks. 24 participants responded with either hands in prone posture (i.e., palm down) and 24 participants responded with either hands in supine (i.e., palm up) posture. When hands were in prone posture, the counting direction of the left hand conflicted with the direction of the left-right MNL, whereas the counting direction of the right hand was consistent with it. When hands were in supine posture, the opposite was true. If systematic associations existed between relative number magnitude and an allocentric spatial representation of the finger series within each hand, as predicted on the basis of counting habits, interactions would be expected between hand posture and a unimanual version of the spatial-numerical association of response codes (SNARC) effect. Data revealed that with hands in prone posture a unimanual SNARC effect was present for the right hand, and with hands in supine posture a unimanual SNARC effect was present for the left hand. We propose that a posture-invariant body structural representation of the finger series provides a relevant frame of reference, a within-hand directional vector, that is associated to simple number processing. Such frame of reference can significantly interact with stimulus-response correspondence effects, like the SNARC, that have been typically attributed to the mapping of numbers on a left-to-right mental line.

  16. Protecting count queries in study design

    PubMed Central

    Sarwate, Anand D; Boxwala, Aziz A

    2012-01-01

    Objective Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. Methods A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Results Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Conclusions Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems. PMID:22511018

  17. Protecting count queries in study design.

    PubMed

    Vinterbo, Staal A; Sarwate, Anand D; Boxwala, Aziz A

    2012-01-01

    Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems.

  18. Means and method for calibrating a photon detector utilizing electron-photon coincidence

    NASA Technical Reports Server (NTRS)

    Srivastava, S. K. (Inventor)

    1984-01-01

    An arrangement for calibrating a photon detector particularly applicable for the ultraviolet and vacuum ultraviolet regions is based on electron photon coincidence utilizing crossed electron beam atom beam collisions. Atoms are excited by electrons which lose a known amount of energy and scatter with a known remaining energy, while the excited atoms emit photons of known radiation. Electrons of the known remaining energy are separated from other electrons and are counted. Photons emitted in a direction related to the particular direction of scattered electrons are detected to serve as a standard. Each of the electrons is used to initiate the measurements of a time interval which terminates with the arrival of a photon exciting the photon detector. Only the number of time intervals related to the coincidence correlation and of electrons scattered in the particular direction with the known remaining energy and photons of a particular radiation level emitted due to the collisions of such scattered electrons are counted. The detector calibration is related to the number of counted electrons and photons.

  19. Variations in pollen counts largely explained by climate and weather

    NASA Astrophysics Data System (ADS)

    Jung, Stephan; Damialis, Athanasios; Estrella, Nicole; Jochner, Susanne; Menzel, Annette

    2017-04-01

    The interaction between climate and vegetation is well studied within phenology. Climatic / weather conditions affect e.g. flowering date, length of vegetation period, start and end of the season and the plant growth. Besides phenological stages also pollen counts can be used to investigate the interaction between climate and vegetation. Pollen emission and distribution is directly influenced by temperature, wind speed, wind direction and humidity/precipitation. The objective of this project is to study daily/sub daily variations in pollen counts of woody and herbaceous plant species along an altitudinal gradient with different climatic conditions during the vegetation period. Measurements of pollen were carried out with three volumetric pollen traps installed at the altitudes 450 m a.s.l (Freising), 700 m a.s.l (Garmisch-Partenkirchen), and 2700 m a.s.l (Schneefernerhaus near Zugspitze) representing gradient from north of Munich towards the highest mountain of Germany. Airborne pollen concentrations were recorded during the years 2014-2015. The altitudinal range of these three stations accompanied by different microclimates ("space for time approach") can be used as proxy for climate change and to assess its impact on pollen counts and thus allergenic risk for human health. For example the pollen season is shortened and pollen amount is reduced at higher sites. For detailed investigations pollen of the species Plantago, Quercus, Poaceae, Cupressaceae, Cyperacea, Betula and Platanus were chosen, because those are found in appropriate quantities. In general, pollen captured in the pollen traps to a certain extent has its origin from the immediate surrounding. Thus, it mirrors local species distribution. But furthermore the distance of pollen transport is also based on (micro-) climatic conditions, land cover and topography. The pollen trap shortly below the summit of Zugspitze (Schneefernerhaus) has an alpine environment without vegetation nearby. Therefore, this trap can be used to detect short-, middle- and long-range pollen transport. The pollen trap in Garmisch-Partenkirchen is located in the valley below Zugspitze making these two stations suitable for a direct comparison. First results show that the total amount of pollen at Schneefernerhaus for Plantago, Quercus, Poaceae, Cupressaceae, Cyperaceae and Betula is only about 20% in comparison to Garmisch. Furthermore there are daily differences in the pollen counts in yearly sum between morning (24:00 -12:00) and afternoon (12:00- 24:00). This phenomenon might be caused by diurnal climatic variations in the boundary layer as well as local mountain wind systems (changing wind direction from morning to afternoon time). Additionally pollen counts were linked to weather data recorded by the German Meteorological Service and local climate stations. Results indicate that the duration of precipitation events is a major factor of influence concerning the counted pollen. With increasing duration of a rain event pollen counts are decreasing.

  20. Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting

    PubMed Central

    Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay

    2016-01-01

    Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e− read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor. PMID:27070625

  1. Single molecule photobleaching (SMPB) technology for counting of RNA, DNA, protein and other molecules in nanoparticles and biological complexes by TIRF instrumentation.

    PubMed

    Zhang, Hui; Guo, Peixuan

    2014-05-15

    Direct counting of biomolecules within biological complexes or nanomachines is demanding. Single molecule counting using optical microscopy is challenging due to the diffraction limit. The single molecule photobleaching (SMPB) technology for direct counting developed by our team (Shu et al., 2007 [18]; Zhang et al., 2007 [19]) offers a simple and straightforward method to determine the stoichiometry of molecules or subunits within biocomplexes or nanomachines at nanometer scales. Stoichiometry is determined by real-time observation of the number of descending steps resulted from the photobleaching of individual fluorophore. This technology has now been used extensively for single molecule counting of protein, RNA, and other macromolecules in a variety of complexes or nanostructures. Here, we elucidate the SMPB technology, using the counting of RNA molecules within a bacteriophage phi29 DNA-packaging biomotor as an example. The method described here can be applied to the single molecule counting of other molecules in other systems. The construction of a concise, simple and economical single molecule total internal reflection fluorescence (TIRF) microscope combining prism-type and objective-type TIRF is described. The imaging system contains a deep-cooled sensitive EMCCD camera with single fluorophore detection sensitivity, a laser combiner for simultaneous dual-color excitation, and a Dual-View™ imager to split the multiple outcome signals to different detector channels based on their wavelengths. Methodology of the single molecule photobleaching assay used to elucidate the stoichiometry of RNA on phi29 DNA packaging motor and the mechanism of protein/RNA interaction are described. Different methods for single fluorophore labeling of RNA molecules are reviewed. The process of statistical modeling to reveal the true copy number of the biomolecules based on binomial distribution is also described. Copyright © 2014 Elsevier Inc. All rights reserved.

  2. What Is the Role of Manual Preference in Hand-Digit Mapping During Finger Counting? A Study in a Large Sample of Right- and Left-Handers.

    PubMed

    Zago, Laure; Badets, Arnaud

    2016-01-01

    The goal of the present study was to test whether there is a relationship between manual preference and hand-digit mapping in 369 French adults with similar numbers of right- and left-handers. Manual laterality was evaluated with the finger tapping test to evaluate hand motor asymmetry, and the Edinburgh handedness inventory was used to assess manual preference strength (MPS) and direction. Participants were asked to spontaneously "count on their fingers from 1 to 10" without indications concerning the hand(s) to be used. The results indicated that both MPS and hand motor asymmetry affect the hand-starting preference for counting. Left-handers with a strong left-hand preference (sLH) or left-hand motor asymmetry largely started to count with their left hand (left-starter), while right-handers with a strong right-hand preference (sRH) or right-hand motor asymmetry largely started to count with their right hand (right-starter). Notably, individuals with weak MPS did not show a hand-starting preference. These findings demonstrated that manual laterality contributes to finger counting directionality. Lastly, the results showed a higher proportion of sLH left-starter individuals compared with sRH right-starters, indicating an asymmetric bias of MPS on hand-starting preference. We hypothesize that the higher proportion of sLH left-starters could be explained by the congruence between left-to-right hand-digit mapping and left-to-right mental number line representation that has been largely reported in the literature. Taken together, these results indicate that finger-counting habits integrate biological and cultural information. © The Author(s) 2015.

  3. Alice Solar Occultation

    NASA Image and Video Library

    2015-07-17

    This figure shows how the Alice instrument count rate changed over time during the sunset and sunrise observations. The count rate is largest when the line of sight to the sun is outside of the atmosphere at the start and end times. Molecular nitrogen (N2) starts absorbing sunlight in the upper reaches of Pluto's atmosphere, decreasing as the spacecraft approaches the planet's shadow. As the occultation progresses, atmospheric methane and hydrocarbons can also absorb the sunlight and further decrease the count rate. When the spacecraft is totally in Pluto's shadow the count rate goes to zero. As the spacecraft emerges from Pluto's shadow into sunrise, the process is reversed. By plotting the observed count rate in the reverse time direction, it is seen that the atmospheres on opposite sides of Pluto are nearly identical. http://photojournal.jpl.nasa.gov/catalog/PIA19716

  4. Application of Microbiological Method Direct Epifluorescence Filter Techique/Aerobic Plate Count Agar in the Identification of Irradiated Herbs and Spices

    PubMed Central

    Di Schiavi, Maria Teresa; Foti, Marina; Mosconi, Maria Cristina; Mattiolo, Giuseppina; Cavallina, Roberta

    2014-01-01

    Irradiation is a preservation technology used to improve the safety and hygienic quality of food. Aim of this study was to assess the applicability and validity of the microbiological screening method direct epifluorescence filter technique (DEFT)/aerobic plate count (APC) (EN 13783:2001) for the identification of irradiated herbs and spices. Tests on non-irradiated and irradiated samples of dried herbs and spices were performed. The method was based on the comparison of APC and count obtained using DEFT. In accordance with the standard reference, this method is not applicable to samples with APC<103 colony forming units (CFU)/g and this is its main limit. The results obtained in our laboratories showed that in 50% of cases of non-irradiated samples and in 96% of the samples treated with ionising radiation, the method was not applicable due to a value of CFU/g <103. PMID:27800348

  5. Method and apparatus for measuring enrichment of UF6

    DOEpatents

    Hill, Thomas Roy [Santa Fe, NM; Ianakiev, Kiril Dimitrov [Los Alamos, NM

    2011-06-07

    A system and method are disclosed for determining the enrichment of .sup.235U in Uranium Hexafluoride (UF6) utilizing synthesized X-rays which are directed at a container test zone containing a sample of UF6. A detector placed behind the container test zone then detects and counts the X-rays which pass through the container and the UF6. In order to determine the portion of the attenuation due to the UF6 gas alone, this count rate may then be compared to a calibration count rate of X-rays passing through a calibration test zone which contains a vacuum, the test zone having experienced substantially similar environmental conditions as the actual test zone. Alternatively, X-rays of two differing energy levels may be alternately directed at the container, where either the container or the UF6 has a high sensitivity to the difference in the energy levels, and the other having a low sensitivity.

  6. Software electron counting for low-dose scanning transmission electron microscopy.

    PubMed

    Mittelberger, Andreas; Kramberger, Christian; Meyer, Jannik C

    2018-05-01

    The performance of the detector is of key importance for low-dose imaging in transmission electron microscopy, and counting every single electron can be considered as the ultimate goal. In scanning transmission electron microscopy, low-dose imaging can be realized by very fast scanning, however, this also introduces artifacts and a loss of resolution in the scan direction. We have developed a software approach to correct for artifacts introduced by fast scans, making use of a scintillator and photomultiplier response that extends over several pixels. The parameters for this correction can be directly extracted from the raw image. Finally, the images can be converted into electron counts. This approach enables low-dose imaging in the scanning transmission electron microscope via high scan speeds while retaining the image quality of artifact-free slower scans. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Epifluorescent direct counts of bacteria and viruses from topsoil of various desert dust storm regions

    USGS Publications Warehouse

    Gonzalez-Martin, Cristina; Teigell-Perez, Nuria; Lyles, Mark; Valladares, Basilio; Griffin, Dale W.

    2013-01-01

    Topsoil from arid regions is the main source of dust clouds that move through the earth's atmosphere, and microbial communities within these soils can survive long-range dispersion. Microbial abundance and chemical composition were analyzed in topsoil from various desert regions. Statistical analyses showed that microbial direct counts were strongly positively correlated with calcium concentrations and negatively correlated with silicon concentrations. While variance between deserts was expected, it was interesting to note differences between sample sites within a given desert region, illustrating the 'patchy' nature of microbial communities in desert environments.

  8. Modification of Point Counts for Surveying Cropland Birds

    Treesearch

    Kathryn Freemark; Catherine Rogers

    1995-01-01

    As part of a comparative study of agricultural impacts on wildlife, modifications to the point count method were evaluated for surveying birds in, and adjacent to, cropland during the breeding season (May to early July) in Ontario. Location in the field, observation direction and distance, number of visits, and number of study sites per farm were examined using point...

  9. When Practice Doesn't Lead to Retrieval: An Analysis of Children's Errors with Simple Addition

    ERIC Educational Resources Information Center

    de Villiers, Celéste; Hopkins, Sarah

    2013-01-01

    Counting strategies initially used by young children to perform simple addition are often replaced by more efficient counting strategies, decomposition strategies and rule-based strategies until most answers are encoded in memory and can be directly retrieved. Practice is thought to be the key to developing fluent retrieval of addition facts. This…

  10. Traffic effects on bird counts on North American Breeding Bird Survey routes

    USGS Publications Warehouse

    Griffith, Emily H.; Sauer, John R.; Royle, J. Andrew

    2010-01-01

    The North American Breeding Bird Survey (BBS) is an annual roadside survey used to estimate population change in >420 species of birds that breed in North America. Roadside sampling has been criticized, in part because traffic noise can interfere with bird counts. Since 1997, data have been collected on the numbers of vehicles that pass during counts at each stop. We assessed the effect of traffic by modeling total vehicles as a covariate of counts in hierarchical Poisson regression models used to estimate population change. We selected species for analysis that represent birds detected at low and high abundance and birds with songs of low and high frequencies. Increases in vehicle counts were associated with decreases in bird counts in most of the species examined. The size and direction of these effects remained relatively constant between two alternative models that we analyzed. Although this analysis indicated only a small effect of incorporating traffic effects when modeling roadside counts of birds, we suggest that continued evaluation of changes in traffic at BBS stops should be a component of future BBS analyses.

  11. High-speed optical switch fabrics with large port count.

    PubMed

    Yeo, Yong-Kee; Xu, Zhaowen; Wang, Dawei; Liu, Jianguo; Wang, Yixin; Cheng, Tee-Hiang

    2009-06-22

    We report a novel architecture that can be used to construct optical switch fabrics with very high port count and nanoseconds switching speed. It is well known that optical switch fabrics with very fast switching time and high port count are challenging to realize. Currently, one of the most promising solutions is based on a combination of wavelength-tunable lasers and the arrayed waveguide grating router (AWGR). To scale up the number of ports in such switches, a direct method is to use AWGRs with a high channel count. However, such AWGRs introduce very large crosstalk noise due to the close wavelength channel spacing. In this paper, we propose an architecture for realizing a high-port count optical switch fabric using a combination of low-port count AWGRs, optical ON-OFF gates and WDM couplers. Using this new methodology, we constructed a proof-of concept experiment to demonstrate the feasibility of a 256 x 256 optical switch fabric. To our knowledge, this port count is the highest ever reported for switch fabrics of this type.

  12. Minimizing the Delay at Traffic Lights

    ERIC Educational Resources Information Center

    Van Hecke, Tanja

    2009-01-01

    Vehicles holding at traffic lights is a typical queuing problem. At crossings the vehicles experience delay in both directions. Longer periods with green lights in one direction are disadvantageous for the vehicles coming from the other direction. The total delay for getting through the traffic point is what counts. This article presents an…

  13. Direct reading of electrocardiograms and respiration rates

    NASA Technical Reports Server (NTRS)

    Wise, J. P.

    1969-01-01

    Technique for reading heart and respiration rates is more accurate and direct than the previous method. Index of a plastic calibrated card is aligned with a point on the electrocardiogram. Complexes are counted as indicated on the card and heart or respiration rate is read directly from the appropriate scale.

  14. Population Size and Distribution of Rhizobium leguminosarum bv. trifolii in Relation to Total Soil Bacteria and Soil Depth †

    PubMed Central

    Bottomley, Peter J.; Dughri, Muktar H.

    1989-01-01

    Bacterial cells small enough to pass through 0.4-μm-pore-size filters made up 5 to 9% of the indigenous bacterial population in 0- to 20-cm-depth samples of Abiqua silty clay loam. Within the same soil samples, cells of a similar dimension were stained with fluorescent antibodies specific to each of four antigenically distinct indigenous serogroups of Rhizobium leguminosarum bv. trifolii and made up 22 to 34% of the soil population of the four serogroups. Despite the extensive contribution of small cells to these soil populations, no evidence of their being capable of either growth or nodulation was obtained. The density of soil bacteria which could be cultured ranged between 0.5 and 8.5% of the >0.4-μm direct count regardless of media, season of sampling, or soil depth. In the same soil samples, the viable nodulating populations of biovar trifolii determined by the plant infection soil dilution technique ranged between 1 and 10% of the >0.4-μm direct-immunofluorescence count of biovar trifolii. The <0.4-μm cell populations of both total soil bacteria and biovar trifolii changed abruptly between the 10- to 15-cm and 15- to 20-cm soil depth increments, increasing from 5 to 20% and from 20 to 50%, respectively, of their direct-count totals. The increase in density of the small-cell population corresponded to a significant increase in soil bulk density (1.07 to 1.21 g cm−3). The percent contribution of the <0.4-μm direct count to individual serogroup totals increased with soil depth by approximately 2-fold (39 to 87%) for serogroups 17 and 21 and by 12-fold (6 to 75%) for serogroups 6 and 36. PMID:16347896

  15. Are Indirect Benefits Relevant to Health Care Allocation Decisions?

    PubMed Central

    Du Toit, Jessica; Millum, Joseph

    2016-01-01

    Abstract When allocating scarce healthcare resources, the expected benefits of alternative allocations matter. But, there are different kinds of benefits. Some are direct benefits to the recipient of the resource such as the health improvements of receiving treatment. Others are indirect benefits to third parties such as the economic gains from having a healthier workforce. This article considers whether only the direct benefits of alternative healthcare resource allocations are relevant to allocation decisions, or whether indirect benefits are relevant too. First, we distinguish different conceptions of direct and indirect benefits and argue that only a recipient conception could be morally relevant. We analyze four arguments for thinking that indirect benefits should not count and argue that none is successful in showing that the indirectness of a benefit is a good reason not to count it. We conclude that direct and indirect benefits should be evaluated in the same way. PMID:27465773

  16. Earthquake dating: an application of carbon-14 atom counting.

    PubMed

    Tucker, A B; Woefli, W; Bonani, G; Suter, M

    1983-03-18

    Milligram-sized specimens of detrital charcoal from soil layers associated with prehistoric earthquakes on the Wasatch fault in Utah have been dated by direct atom counting of carbon-14 with a tandem Van de Graaff accelerator. The measured ratios of carbon-14 to carbon-12 correspond to ages of 7800, 8800, and 9000 years with uncertainties of +/- 600 years.

  17. Raman scattering method and apparatus for measuring isotope ratios and isotopic abundances

    DOEpatents

    Harney, Robert C.; Bloom, Stewart D.

    1978-01-01

    Raman scattering is used to measure isotope ratios and/or isotopic abundances. A beam of quasi-monochromatic photons is directed onto the sample to be analyzed, and the resulting Raman-scattered photons are detected and counted for each isotopic species of interest. These photon counts are treated mathematically to yield the desired isotope ratios or isotopic abundances.

  18. Rapid and direct detection of Invivo kinetics of pathogenic bacterial infection from mouse blood and urine.

    PubMed

    Gopal, Judy; Lee, Chia-Hsun; Wu, Hui-Fen

    2012-06-06

    This study demonstrates the first use of matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) to trace the Invivo infection kinetics of the well known deadly pathogen Staphylococcus aureus in Swiss albino mice. The growth curve of the bacteria from the point of injection (200μL of bacterial suspension (10(8)cfu/mL)) into the mouse blood till mortality (death) was periodically analyzed using the plate counting method and MALDI-MS. Bacterial counts of 10(3)cfu/mL were observed in the log phase of the growth curve in the blood and 10(2)cfu/mL were observed in the urine samples. Death occurred in the log phase of the growth curve, where the bacterial counts showed steady increase. In other cases, the bacteria counts started decreasing after 48h and by 96h the bacteria got totally eliminated from the mouse and these mice survived. Direct MALDI-MS was not feasible for tracking the bacteria in the infected blood. However, ionic liquid 1-Butyl-3-methylimidazolium tetrafluoroborate was successful in enabling bacterial detection amidst the strong blood peaks. But, in the case of the urine analysis, it was observed that direct MALDI-MS was adequate to enable detection. The results obtained prove the efficacy of MALDI-MS for analyzing pathogenic bacteria in clinical samples. This article is part of a Special Issue entitled: Proteomics: The clinical link. Copyright © 2011 Elsevier B.V. All rights reserved.

  19. The observability principle and beyond. Reply to comments on "Seeing mental states: An experimental strategy for measuring the observability of other minds" by Cristina Becchio et al.

    NASA Astrophysics Data System (ADS)

    Becchio, Cristina; Koul, Atesh; Ansuini, Caterina; Bertone, Cesare; Cavallo, Andrea

    2018-03-01

    Is it possible to directly perceive others' mental states? Mediating the debate between Direct Perception and Inferentialism proponents would require knowing "what counts as an inference and how to tell the difference between inferential and non-inferential processing" [1]. However, few theorists have even attempted to answer the question of what counts as inference. The consequence, as noted by Spaulding [1], is that "given that neither Inferentialists nor DSP [Direct Social Perception, Ed.] proponents specify what they mean by inference, it is hard to tell what exactly each side is affirming and denying. Thus, the debate between Inferentialism and DSP is at an impasse". Similar considerations apply to distinguishing between what is 'observable' versus 'unobservable' [2].

  20. Orthogonal bases of invariants in tensor models

    NASA Astrophysics Data System (ADS)

    Diaz, Pablo; Rey, Soo-Jong

    2018-02-01

    Representation theory provides an efficient framework to count and classify invariants in tensor models of (gauge) symmetry G d = U( N 1) ⊗ · · · ⊗ U( N d ) . We show that there are two natural ways of counting invariants, one for arbitrary G d and another valid for large rank of G d . We construct basis of invariant operators based on the counting, and compute correlators of their elements. The basis associated with finite rank of G d diagonalizes two-point function. It is analogous to the restricted Schur basis used in matrix models. We comment on future directions for investigation.

  1. Extensive brain masses and cavitary lung lesions associated with toxoplasmosis and acquired immunodeficiency syndrome.

    PubMed

    Ayoade, Folusakin; Todd, John; Al-Delfi, Firas; King, John

    2017-10-01

    Toxoplasmosis is an important cause of enhancing brain lesions in patients with acquired immunodeficiency syndrome (AIDS), and it is typically associated with low CD4-lymphocyte counts. Extensive toxoplasma encephalitis when the CD4-lymphocyte count is above 100 cells/µl is unusual. Cavitary lung lesions are also not typically associated with toxoplasmosis. Here, we present a case of toxoplasmosis associated with extensive brain masses and cavitary lung lesions, both of which improved with directed toxoplasmosis therapy, in an AIDS patient with a CD4 cell count of 120 cells/µl.

  2. PHASE DIFFERENTIAL INDICATING CIRCUIT

    DOEpatents

    Kirsten, F.A.

    1962-01-01

    An electronic circuit for totalizing the net phase difference between two alternating current signals is designed which responds to both increasing and decreasing phase changes. A phase comparator provldes an output pulse for each 360 deg of phase difference occurring, there being a negative pulse for phase shtft in one direction and a positive pulse for a phase shift in the opposite direction. A counting circuit utilizing glow discharge tubes receives the negative and positive pulses at a single input terminal and provides a running net total, pulses of one polarity dded and pulses of the opposite polarity being subtracted. The glow discharge tubes may be decaded to increase the total count capacity. (AEC)

  3. Direct viable count as test for toxicity assessment: the effects of four metals on a Salmonella enteritidis strain.

    PubMed

    Scoglio, M E; Di Pietro, A; Anzalone, C; Calimeri, S; Lo Giudice, D; Trimarchi, G R

    2000-01-01

    The toxicity of synthetic sewage containing increasing concentrations of arsenic (.125, .25, .5, 1.0 mg L-1), cadmium (.02, .05, .1, .2 mg L-1), lead (.2, .5, 1.0, 2.0 mg L-1) and nickel (.5, 1.0, 2.0, 4.0 mg L-1) has been investigated by determining the total direct count (TDC) and the direct viable count (DVC) of Salmonella enteritidis by means of an immunofluorescence technique (IFA). This has been done in order to evaluate the possibility of using the IFA technique to estimate the toxicity of complex effluents. Arsenic, cadmium and nickel produced a concentration-dependent reduction in the number of viable bacterial cells. This was more clear when the viable bacterial cells were considered than when only the culturable part was used. Lead did not show a concentration-dependent and reproducible effect. At the highest concentrations allowed by the Italian wastewater regulations, lead, cadmium, arsenic and nickel reduced the viable/total bacterial cells ratio to 74.5%, 68.5%, 28.4% and 6.9%, respectively. The toxic effects of the metals were also tested using the standard Microtox assay.

  4. A Next Generation Digital Counting System For Low-Level Tritium Studies (Project Report)

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bowman, P.

    2016-10-03

    Since the early seventies, SRNL has pioneered low-level tritium analysis using various nuclear counting technologies and techniques. Since 1999, SRNL has successfully performed routine low-level tritium analyses with counting systems based on digital signal processor (DSP) modules developed in the late 1990s. Each of these counting systems are complex, unique to SRNL, and fully dedicated to performing routine tritium analyses of low-level environmental samples. It is time to modernize these systems due to a variety of issues including (1) age, (2) lack of direct replacement electronics modules and (3) advances in digital signal processing and computer technology. There has beenmore » considerable development in many areas associated with the enterprise of performing low-level tritium analyses. The objective of this LDRD project was to design, build, and demonstrate a Next Generation Tritium Counting System (NGTCS), while not disrupting the routine low-level tritium analyses underway in the facility on the legacy counting systems. The work involved (1) developing a test bed for building and testing new counting system hardware that does not interfere with our routine analyses, (2) testing a new counting system based on a modern state of the art DSP module, and (3) evolving the low-level tritium counter design to reflect the state of the science.« less

  5. 45 CFR 261.31 - How many hours must a work-eligible individual participate for the family to count in the...

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ...; education directly related to employment; and satisfactory attendance at secondary school or in a course of... Simplified Food Stamp Program option that permits a State to count the value of food stamps in determining... does not have a traditional Food Stamp Program, to deem core hours, it must include the value of food...

  6. Medicare and Graduate Medical Education.

    DTIC Science & Technology

    1995-09-01

    research. The physician counts reported here are based on American Medical Association counts of doctors of medicine (M.D.s). Schools of osteopathy ...whose graduates receive a doctor of osteopathy degree, produce about 5 percent of a more broadly defined physician workforce. Even critics who have...provided insurance, and federal subsi- dies directed toward the supply of physicians. Con- ventional economic analysis would stress that in the

  7. Total and Viable Legionella pneumophila Cells in Hot and Natural Waters as Measured by Immunofluorescence-Based Assays and Solid-Phase Cytometry ▿†

    PubMed Central

    Parthuisot, N.; Binet, M.; Touron-Bodilis, A.; Pougnard, C.; Lebaron, P.; Baudart, J.

    2011-01-01

    A new method was developed for the rapid and sensitive detection of viable Legionella pneumophila. The method combines specific immunofluorescence (IF) staining using monoclonal antibodies with a bacterial viability marker (ChemChrome V6 cellular esterase activity marker) by means of solid-phase cytometry (SPC). IF methods were applied to the detection and enumeration of both the total and viable L. pneumophila cells in water samples. The sensitivity of the IF methods coupled to SPC was 34 cells liter−1, and the reproducibility was good, with the coefficient of variation generally falling below 30%. IF methods were applied to the enumeration of total and viable L. pneumophila cells in 46 domestic hot water samples as well as in cooling tower water and natural water samples, such as thermal spring water and freshwater samples. Comparison with standard plate counts showed that (i) the total direct counts were always higher than the plate counts and (ii) the viable counts were higher than or close to the plate counts. With domestic hot waters, when the IF assay was combined with the viability test, SPC detected up to 3.4 × 103 viable but nonculturable L. pneumophila cells per liter. These direct IF methods could be a powerful tool for high-frequency monitoring of domestic hot waters or for investigating the occurrence of viable L. pneumophila in both man-made water systems and environmental water samples. PMID:21742913

  8. Physical characterization of a scanning photon counting digital mammography system based on Si-strip detectors.

    PubMed

    Aslund, Magnus; Cederström, Björn; Lundqvist, Mats; Danielsson, Mats

    2007-06-01

    The physical performance of a scanning multislit full field digital mammography system was determined using basic image quality parameters. The system employs a direct detection detector comprised of linear silicon strip sensors in an edge-on geometry connected to photon counting electronics. The pixel size is 50 microm and the field of view 24 x 26 cm2. The performance was quantified using the presampled modulation transfer function, the normalized noise power spectrum and the detective quantum efficiency (DQE). Compared to conventional DQE methods, the scanning geometry with its intrinsic scatter rejection poses additional requirements on the measurement setup, which are investigated in this work. The DQE of the photon counting system was found to be independent of the dose level to the detector in the 7.6-206 microGy range. The peak DQE was 72% and 73% in the scan and slit direction, respectively, measured with a 28 kV W-0.5 mm Al anode-filter combination with an added 2 mm Al filtration.

  9. Skull counting in late stages after internal contamination by actinides.

    PubMed

    Tani, Kotaro; Shutt, Arron; Kurihara, Osamu; Kosako, Toshiso

    2015-02-01

    Monitoring preparation for internal contamination with actinides (e.g. Pu and Am) is required to assess internal doses at nuclear fuel cycle-related facilities. In this paper, the authors focus on skull counting in case of single-incident inhalation of (241)Am and propose an effective procedure for skull counting with an existing system, taking into account the biokinetic behaviour of (241)Am in the human body. The predicted response of the system to skull counting under a certain counting geometry was found to be only ∼1.0 × 10(-5) cps Bq(-1) 1y after intake. However, this disadvantage could be remedied by repeated measurements of the skull during the late stage of the intake due to the predicted response reaching a plateau at about the 1000th day after exposure and exceeding that in the lung counting. Further studies are needed for the development of a new detection system with higher sensitivity to perform reliable internal dose estimations based on direct measurements. © The Author 2014. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study.

    PubMed

    Cho, H-M; Ding, H; Ziemer, B P; Molloi, S

    2014-12-07

    Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using x-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for x-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm(2) in detection area. The angular dependence of x-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded x-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of x-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of x-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic x-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the x-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory.

  11. Energy response calibration of photon-counting detectors using x-ray fluorescence: a feasibility study

    NASA Astrophysics Data System (ADS)

    Cho, H.-M.; Ding, H.; Ziemer, BP; Molloi, S.

    2014-12-01

    Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using x-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for x-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3  ×  3 mm2 in detection area. The angular dependence of x-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded x-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of x-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of x-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic x-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the x-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory.

  12. Energy response calibration of photon-counting detectors using X-ray fluorescence: a feasibility study

    PubMed Central

    Cho, H-M; Ding, H; Ziemer, BP; Molloi, S

    2014-01-01

    Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using X-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for X-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm2 in detection area. The angular dependence of X-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded X-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of X-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of X-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic X-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the X-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory. PMID:25369288

  13. Physiological responses of bacteria in biofilms to disinfection.

    PubMed Central

    Yu, F P; McFeters, G A

    1994-01-01

    In situ enumeration methods using fluorescent probes and a radioisotope labelling technique were applied to evaluate physiological changes of Klebsiella pneumoniae within biofilms after disinfection treatment. Chlorine (0.25 mg of free chlorine per liter [pH 7.2]) and monochloramine (1 mg/liter [pH 9.0]) were employed as disinfectants in the study. Two fluorgenic compounds, 5-cyano-2,3-ditolyl tetrazolium chloride and rhodamine 123, and tritiated uridine incorporation were chosen for assessment of physiological activities. Results obtained by these methods were compared with those from the plate count and direct viable count methods. 5-Cyano-2,3-ditolyl tetrazolium chloride is an indicator of bacterial respiratory activity, rhodamine 123 is incorporated into bacteria in response to transmembrane potential, and the incorporation of uridine represents the global RNA turnover rate. The results acquired by these methods following disinfection exposure showed a range of responses and suggested different physiological reactions in biofilms exposed to chlorine and monochloramine. The direct viable count response and respiratory activity were affected more by disinfection than were the transmembrane potential and RNA turnover rate on the basis of comparable efficiency as evaluated by plate count enumeration. Information revealed by these approaches can provide different physiological insights that may be used in evaluating the efficacy of biofilm disinfection. PMID:8074525

  14. Population trends of the common murre (Uria aalge californica)

    USGS Publications Warehouse

    Carter, Harry R.; Wilson, Ulrich W.; Lowe, Roy W.; Rodway, M.S.; Manuwal, David Allen; Takekawa, Jean E.; Yee, Julie L.; Manuwal, David Allen; Carter, Harry R.; Zimmerman, Tara S.; Orthmeyer, Dennis L.

    2001-01-01

    Population trends for the common murre (Uria aalge californica) were determined from available whole-colony counts of murres in California, Oregon, Washington, and British Columbia from 1800 to 1995.From 1800 to 1978, historical counts were sporadic and not standardized. From 1979 to 1995, standardized whole-colony counts from aerial photographs were conducted in many years in California, Oregon, and Washington. In contrast, no aerial photographs of murre colonies in British Columbia have been taken and only a few other whole-colony counts have been conducted. Direct comparisons and statistical treatment of whole-colony counts were conducted using 1979-95 data. Complete data for all colonies were available only in 1988-89 when the breeding murre population was estimated to be 1.1 million, about 5-8% of the world population and 13-28% of the Pacific Ocean population. A summary of various natural and anthropogenic factors affecting murre populations in western North America since 1800, and particularly in 1979-95, also is provided.

  15. Hybrid statistics-simulations based method for atom-counting from ADF STEM images.

    PubMed

    De Wael, Annelies; De Backer, Annick; Jones, Lewys; Nellist, Peter D; Van Aert, Sandra

    2017-06-01

    A hybrid statistics-simulations based method for atom-counting from annular dark field scanning transmission electron microscopy (ADF STEM) images of monotype crystalline nanostructures is presented. Different atom-counting methods already exist for model-like systems. However, the increasing relevance of radiation damage in the study of nanostructures demands a method that allows atom-counting from low dose images with a low signal-to-noise ratio. Therefore, the hybrid method directly includes prior knowledge from image simulations into the existing statistics-based method for atom-counting, and accounts in this manner for possible discrepancies between actual and simulated experimental conditions. It is shown by means of simulations and experiments that this hybrid method outperforms the statistics-based method, especially for low electron doses and small nanoparticles. The analysis of a simulated low dose image of a small nanoparticle suggests that this method allows for far more reliable quantitative analysis of beam-sensitive materials. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. Microbiological survey of five poultry processing plants in the UK.

    PubMed

    Mead, G C; Hudson, W R; Hinton, M H

    1993-07-01

    1. Neck skin samples were taken from chickens and turkeys at all the main stages of processing to monitor changes in total viable count (TVC) and counts of coliforms and pseudomonads. 2. Processing reduced TVC by up to 100-fold. Geometric mean counts after packaging were log10 4.4 to 5.3 CFU/g whilst corresponding counts of coliforms were 2.7 to 3.8 CFU/g. 3. Increases in mean TVC or coliforms as a result of either defeathering or evisceration did not exceed 0.6 log. 4. Pseudomonads represented only a minor fraction of the initial microflora of the bird and were often reduced by scalding to a figure which could not be detected by direct plating of samples; however, subsequent contamination resulted in means between log10 2.9 and 4.0 CFU/g for packaged carcases. 5. Although Staphylococcus aureus was readily isolated from defeathering equipment, mean counts from defeathered carcases were always below log10 3.0 CFU/g.

  17. Are Indirect Benefits Relevant to Health Care Allocation Decisions?

    PubMed

    Du Toit, Jessica; Millum, Joseph

    2016-10-01

    When allocating scarce healthcare resources, the expected benefits of alternative allocations matter. But, there are different kinds of benefits. Some are direct benefits to the recipient of the resource such as the health improvements of receiving treatment. Others are indirect benefits to third parties such as the economic gains from having a healthier workforce. This article considers whether only the direct benefits of alternative healthcare resource allocations are relevant to allocation decisions, or whether indirect benefits are relevant too. First, we distinguish different conceptions of direct and indirect benefits and argue that only a recipient conception could be morally relevant. We analyze four arguments for thinking that indirect benefits should not count and argue that none is successful in showing that the indirectness of a benefit is a good reason not to count it. We conclude that direct and indirect benefits should be evaluated in the same way. Published by Oxford University Press on behalf of the Journal of Medicine and Philosophy, Inc. 2016.

  18. Bacterial density and community structure associated with aggregate size fractions of soil-feeding termite mounds.

    PubMed

    Fall, S; Nazaret, S; Chotte, J L; Brauman, A

    2004-08-01

    The building and foraging activities of termites are known to modify soil characteristics such as the heterogeneity. In tropical savannas the impact of the activity of soil-feeding termites ( Cubitermes niokoloensis) has been shown to affect the properties of the soil at the aggregate level by creating new soil microenvironments (aggregate size fractions) [13]. These changes were investigated in greater depth by looking at the microbial density (AODC) and the genetic structure (automated rRNA intergenic spacer analysis: ARISA) of the communities in the different aggregate size fractions (i.e., coarse sand, fine sand, coarse silt, fine silt, and dispersible clays) separated from compartments (internal and external wall) of three Cubitermes niokoloensis mounds. The bacterial density of the mounds was significantly higher (1.5 to 3 times) than that of the surrounding soil. Within the aggregate size fractions, the termite building activity resulted in a significant increase in bacterial density within the coarser fractions (>20 mum). Multivariate analysis of the ARISA profiles revealed that the bacterial genetic structures of unfractionated soil and soil aggregate size fractions of the three mounds was noticeably different from the savanna soil used as a reference. Moreover, the microbial community associated with the different microenvironments in the three termite mounds revealed three distinct clusters formed by the aggregate size fractions of each mound. Except for the 2-20 mum fraction, these results suggest that the mound microbial genetic structure is more dependent upon microbial pool affiliation (the termite mound) than on the soil location (aggregate size fraction). The causes of the specificity of the microbial community structure of termite mound aggregate size fractions are discussed.

  19. Method for spatially distributing a population

    DOEpatents

    Bright, Edward A [Knoxville, TN; Bhaduri, Budhendra L [Knoxville, TN; Coleman, Phillip R [Knoxville, TN; Dobson, Jerome E [Lawrence, KS

    2007-07-24

    A process for spatially distributing a population count within a geographically defined area can include the steps of logically correlating land usages apparent from a geographically defined area to geospatial features in the geographically defined area and allocating portions of the population count to regions of the geographically defined area having the land usages, according to the logical correlation. The process can also include weighing the logical correlation for determining the allocation of portions of the population count and storing the allocated portions within a searchable data store. The logically correlating step can include the step of logically correlating time-based land usages to geospatial features of the geographically defined area. The process can also include obtaining a population count for the geographically defined area, organizing the geographically defined area into a plurality of sectors, and verifying the allocated portions according to direct observation.

  20. Increased circulating blood cell counts in combat-related PTSD: Associations with inflammation and PTSD severity.

    PubMed

    Lindqvist, Daniel; Mellon, Synthia H; Dhabhar, Firdaus S; Yehuda, Rachel; Grenon, S Marlene; Flory, Janine D; Bierer, Linda M; Abu-Amara, Duna; Coy, Michelle; Makotkine, Iouri; Reus, Victor I; Aschbacher, Kirstin; Bersani, F Saverio; Marmar, Charles R; Wolkowitz, Owen M

    2017-12-01

    Inflammation is reported in post-traumatic stress disorder (PTSD). Few studies have investigated circulating blood cells that may contribute to inflammation. We assessed circulating platelets, white blood cells (WBC) and red blood cells (RBC) in PTSD and assessed their relationship to inflammation and symptom severity. One-hundred and sixty-three male combat-exposed veterans (82 PTSD, 81 non-PTSD) had blood assessed for platelets, WBC, and RBC. Data were correlated with symptom severity and inflammation. All cell counts were significantly elevated in PTSD. There were small mediation effects of BMI and smoking on these relationships. After adjusting for these, the differences in WBC and RBC remained significant, while platelet count was at trend level. In all subjects, all of the cell counts correlated significantly with inflammation. Platelet count correlated with inflammation only in the PTSD subjects. Platelet count, but none of the other cell counts, was directly correlated with PTSD severity ratings in the PTSD group. Combat PTSD is associated with elevations in RBC, WBC, and platelets. Dysregulation of all three major lineages of hematopoietic cells in PTSD, as well as their significant correlation with inflammation, suggest clinical significance of these changes. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. A direct viable count method for the enumeration of attached bacteria and assessment of biofilm disinfection

    NASA Technical Reports Server (NTRS)

    Yu, F. P.; Pyle, B. H.; McFeters, G. A.

    1993-01-01

    This report describes the adaptation of an in situ direct viable count (in situ DVC) method in biofilm disinfection studies. The results obtained with this technique were compared to two other enumeration methods, the plate count (PC) and conventional direct viable count (c-DVC). An environmental isolate (Klebsiella pneumoniae Kp1) was used to form biofilms on stainless steel coupons in a stirred batch reactor. The in situ DVC method was applied to directly assess the viability of bacteria in biofilms without disturbing the integrity of the interfacial community. As additional advantages, the results were observed after 4 h instead of the 24 h incubation time required for colony formation and total cell numbers that remained on the substratum were enumerated. Chlorine and monochloramine were used to determine the susceptibilities of attached and planktonic bacteria to disinfection treatment using this novel analytical approach. The planktonic cells in the reactor showed no significant change in susceptibility to disinfectants during the period of biofilm formation. In addition, the attached cells did not reveal any more resistance to disinfection than planktonic cells. The disinfection studies of young biofilms indicated that 0.25 mg/l free chlorine (at pH 7.2) and 1 mg/l monochloramine (at pH 9.0) have comparable disinfection efficiencies at 25 degrees C. Although being a weaker disinfectant, monochloramine was more effective in removing attached bacteria from the substratum than free chlorine. The in situ DVC method always showed at least one log higher viable cell densities than the PC method, suggesting that the in situ DVC method is more efficient in the enumeration of biofilm bacteria. The results also indicated that the in situ DVC method can provide more accurate information regarding the cell numbers and viability of bacteria within biofilms following disinfection.

  2. Direct Observations of ULF and Whistler-Mode Chorus Modulation of 500eV EDI Electrons by MMS

    NASA Astrophysics Data System (ADS)

    Paulson, K. W.; Argall, M. R.; Ahmadi, N.; Torbert, R. B.; Le Contel, O.; Ergun, R.; Khotyaintsev, Y. V.; Strangeway, R. J.; Magnes, W.; Russell, C. T.

    2016-12-01

    We present here direct observations of chorus-wave modulated field-aligned 500 eV electrons using the Electron Drift Instrument (EDI) on board the Magnetospheric Multiscale mission. These periods of wave activity were additionally observed to be modulated by Pc5-frequency magnetic perturbations, some of which have been identified as drifting mirror-mode structures. The spacecraft encountered these mirror-mode structures just inside of the duskside magnetopause. Using the high sampling rate provided by EDI in burst sampling mode, we are able to observe the individual count fluctuations of field-aligned electrons in this region up to 512 Hz. We use the multiple look directions of EDI to generate both pitch angle and gyrophase plots of the fluctuating counts. Our observations often show unidirectional flow of these modulated electrons along the background field, and in some cases demonstrate gyrophase bunching in the wave region.

  3. The topology of galaxy clustering.

    NASA Astrophysics Data System (ADS)

    Coles, P.; Plionis, M.

    The authors discuss an objective method for quantifying the topology of the galaxy distribution using only projected galaxy counts. The method is a useful complement to fully three-dimensional studies of topology based on the genus by virtue of the enormous projected data sets available. Applying the method to the Lick counts they find no evidence for large-scale non-gaussian behaviour, whereas the small-scale distribution is strongly non-gaussian, with a shift in the meatball direction.

  4. The Republic of Turkey: Intercultural Education and the Colorado Air National Guard.

    DTIC Science & Technology

    1981-05-01

    LESSON 9 1. Our goal in language 30 - 40 phrases 180 plus counting A - greetings, general phrases - eating habits & foods - directions - counting...Turkish coffee Alafranga kahve. Nescafe Tea (;ay (Breakfast continued) Bread, butter, jamn Ekmek, tereya§. reqel Egg Vumurta Fruit juice Meyve suyu Toast...Excuse me. Afferdersiniz Breakfast kahvalti Tea jay Coffee kahve Bread ekmek Fruit juice Meyve suyu Egg yumurta Milk sut Sugar 9eker Meat et Beef

  5. The sensitivity of direct faecal examination, direct faecal flotation, modified centrifugal faecal flotation and centrifugal sedimentation/flotation in the diagnosis of canine spirocercosis.

    PubMed

    Christie, J; Schwan, E V; Bodenstein, L L; Sommerville, J E M; van der Merwe, L L

    2011-06-01

    Several faecal examination techniques have shown variable sensitivity in demonstrating Spirocerca lupi (S. lupi) eggs. The objective of this study was to determine which faecal examination technique, including a novel modified centrifugal flotation technique, was most sensitive to diagnose spirocercosis. Ten coproscopic examinations were performed on faeces collected from 33 dogs confirmed endoscopically to have spirocercosis. The tests included a direct faecal examination, a faecal sedimentation/flotation test, 4 direct faecal flotations and 4 modified faecal centrifugal flotations. These latter 2 flotation tests utilised 4 different faecal flotation solutions: NaNO3 (SG 1.22), MgSO4 (SG 1.29), ZnSO4 (SG 1.30) and sugar (SG 1.27). The sensitivity of the tests ranged between 42% and 67%, with the NaNO3 solution showing the highest sensitivity in both the direct and modified-centrifugal flotations. The modified NaNO3 centrifugal method ranked 1st with the highest mean egg count (45.24 +/- 83), and was superior (i.e. higher egg count) and significantly different (P < 0.05) compared with the routine saturated sugar, ZnSO4 and MgSO4 flotation methods. The routine NaNO3 flotation method was also superior and significantly different (P < 0.05) compared with the routine ZnSO4 and MgSO4 flotation methods. Fifteen per cent (n = 5) of dogs had neoplastic oesophageal nodules and a further 18% (n = 6) had both neoplastic and non-neoplastic nodules. S. lupi eggs were demonstrated in 40% of dogs with neoplastic nodules only and 72.9% of the dogs with non-neoplastic nodules. The mean egg count in the non-neoplastic group (61) was statistically greater (P = 0.02) than that of the neoplastic group (1). The results show that faecal examination using a NaNO3 solution is the most sensitive in the diagnosis of spirocercosis. The modified centrifugal flotation faecal method using this solution has the highest egg count. The study also found that dogs with neoplastic nodules shed significantly fewer eggs than dogs with non-neoplastic nodules.

  6. Improved Method for Determination of Respiring Individual Microorganisms in Natural Waters

    PubMed Central

    Tabor, Paul S.; Neihof, Rex A.

    1982-01-01

    A method is reported that combines the microscopic determinations of specific, individual, respiring microorganisms by the detection of electron transport system activity and the total number of organisms of an estuarine population by epifluorescence microscopy. An active cellular electron transport system specifically reduces 2-(p-iodophenyl)-3-(p-nitrophenyl)-5-phenyl tetrazolium chloride (INT) to INT-formazan, which is recognized as opaque intracellular deposits in microorganisms stained with acridine orange. In a comparison of previously described sample preparation techniques, a loss of >70% of the counts of INT-reducing microorganisms was shown to be due to the dissolution of INT-formazan deposits by immersion oil (used in microscopy). In addition, significantly fewer fluorescing microorganisms and INT-formazan deposits, both ≤0.2 μm in size, were found for sample preparations that included a Nuclepore filter. Visual clarity was enhanced, and significantly greater direct counts and counts of INT-reducing microorganisms were recognized by transferring microorganisms from a filter to a gelatin film on a cover glass, followed by coating the sample with additional gelatin to produce a transparent matrix. With this method, the number of INT-reducing microorganisms determined for a Chesapeake Bay water sample was 2-to 10-fold greater than the number of respiring organisms reported previously for marine or freshwater samples. INT-reducing microorganisms constituted 61% of the total direct counts determined for a Chesapeake Bay water sample. This is the highest percentage of metabolically active microorganisms of any aquatic population reported using a method which determines both total counts and specific activity. PMID:16346025

  7. Improved method for determination of respiring individual microorganisms in natural waters.

    PubMed

    Tabor, P S; Neihof, R A

    1982-06-01

    A method is reported that combines the microscopic determinations of specific, individual, respiring microorganisms by the detection of electron transport system activity and the total number of organisms of an estuarine population by epifluorescence microscopy. An active cellular electron transport system specifically reduces 2-(p-iodophenyl)-3-(p-nitrophenyl)-5-phenyl tetrazolium chloride (INT) to INT-formazan, which is recognized as opaque intracellular deposits in microorganisms stained with acridine orange. In a comparison of previously described sample preparation techniques, a loss of >70% of the counts of INT-reducing microorganisms was shown to be due to the dissolution of INT-formazan deposits by immersion oil (used in microscopy). In addition, significantly fewer fluorescing microorganisms and INT-formazan deposits, both

  8. Performance simulation of an x-ray detector for spectral CT with combined Si and Cd[Zn]Te detection layers

    NASA Astrophysics Data System (ADS)

    Herrmann, Christoph; Engel, Klaus-Jürgen; Wiegert, Jens

    2010-12-01

    The most obvious problem in obtaining spectral information with energy-resolving photon counting detectors in clinical computed tomography (CT) is the huge x-ray flux present in conventional CT systems. At high tube voltages (e.g. 140 kVp), despite the beam shaper, this flux can be close to 109 Mcps mm-2 in the direct beam or in regions behind the object, which are close to the direct beam. Without accepting the drawbacks of truncated reconstruction, i.e. estimating missing direct-beam projection data, a photon-counting energy-resolving detector has to be able to deal with such high count rates. Sub-structuring pixels into sub-pixels is not enough to reduce the count rate per pixel to values that today's direct converting Cd[Zn]Te material can cope with (<=10 Mcps in an optimistic view). Below 300 µm pixel pitch, x-ray cross-talk (Compton scatter and K-escape) and the effect of charge diffusion between pixels are problematic. By organising the detector in several different layers, the count rate can be further reduced. However this alone does not limit the count rates to the required level, since the high stopping power of the material becomes a disadvantage in the layered approach: a simple absorption calculation for 300 µm pixel pitch shows that the required layer thickness of below 10 Mcps/pixel for the top layers in the direct beam is significantly below 100 µm. In a horizontal multi-layer detector, such thin layers are very difficult to manufacture due to the brittleness of Cd[Zn]Te. In a vertical configuration (also called edge-on illumination (Ludqvist et al 2001 IEEE Trans. Nucl. Sci. 48 1530-6, Roessl et al 2008 IEEE NSS-MIC-RTSD 2008, Conf. Rec. Talk NM2-3)), bonding of the readout electronics (with pixel pitches below 100 µm) is not straightforward although it has already been done successfully (Pellegrini et al 2004 IEEE NSS MIC 2004 pp 2104-9). Obviously, for the top detector layers, materials with lower stopping power would be advantageous. The possible choices are, however, quite limited, since only 'mature' materials, which operate at room temperature and can be manufactured reliably should reasonably be considered. Since GaAs is still known to cause reliability problems, the simplest choice is Si, however with the drawback of strong Compton scatter which can cause considerable inter-pixel cross-talk. To investigate the potential and the problems of Si in a multi-layer detector, in this paper the combination of top detector layers made of Si with lower layers made of Cd[Zn]Te is studied by using Monte Carlo simulated detector responses. It is found that the inter-pixel cross-talk due to Compton scatter is indeed very high; however, with an appropriate cross-talk correction scheme, which is also described, the negative effects of cross-talk are shown to be removed to a very large extent.

  9. Auroral, Polar Cap, and Polar Cusp Modeling and Data Analysis for the IMAGE Mission and LENA Instrument

    NASA Technical Reports Server (NTRS)

    Wilson, Gordon R.

    2001-01-01

    One of the chief mysteries in the LENA perigee pass data is the lack of an apparent auroral oval in the images. Another is that in some cases ENA are seen from any direction near the Earth regardless of the latitude of the spacecraft. These facts lead one to ask a fundamental question: Is the instrument responding to ENA primarily? One possible way to get out of the "ambiguity" of the data is to assume that at least part of the signal is produced by something other than ENA. The two main candidates for this "something else" are UV light and energetic charged particles. UV light could only effect the instrument when its fan shaped aperture points toward the source. The most intense of which will be the sun, with day glow being the second strongest and the auroral zone, the third. We can rule out UV light as a prime source of counts in the perigee pass data for the following reasons: 1) The perigee pass signal is different in form and much stronger than the sun pulse signal seen just before or just after perigee; 2) There is no indication of the auroral zone, which would produce at least two peaks in the counts versus spin phase curve; 3) Mike Colliers' analysis of the sun pulse signal shows that it varies with the flux of the solar wind and not with variations in the solar UV flux. Charge particles that enter the aperture of the instrument and produce counts would show up when the instrument looks in the direction from which they come. In all of the data I am analyzing voltages were being applied to the collimators so that most charged particles should have been excluded from the instrument but this effect could still show up where the flux of energetic particles is high enough. The most likely place would be in the auroral zone where energetic electrons and protons precipitate. If these particles are producing counts then they should be seen when the instrument looks in and near the zenith direction. In nearly all of the perigee passes the zenith direction is devoid of counts.

  10. HIGH VOLTAGE GENERATOR

    DOEpatents

    Zito, G.V.

    1959-04-21

    This patent relates to high voltage supply circuits adapted for providing operating voltages for GeigerMueller counter tubes, and is especially directed to an arrangement for maintaining uniform voltage under changing conditions of operation. In the usual power supply arrangement for counter tubes the counter voltage is taken from across the power supply output capacitor. If the count rate exceeds the current delivering capaciiy of the capacitor, the capacitor voltage will drop, decreasing the counter voltage. The present invention provides a multivibrator which has its output voltage controlled by a signal proportional to the counting rate. As the counting rate increases beyond the current delivering capacity of the capacitor, the rectified voltage output from the multivibrator is increased to maintain uniform counter voltage.

  11. A photon-counting photodiode array detector for far ultraviolet (FUV) astronomy

    NASA Technical Reports Server (NTRS)

    Hartig, G. F.; Moos, H. W.; Pembroke, R.; Bowers, C.

    1982-01-01

    A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location.

  12. ELECTRICAL PULSE COUNTER APPARATUS

    DOEpatents

    Kaufman, W.M.; Jeeves, T.A.

    1962-09-01

    A progressive electrical pulse counter circuit rs designed for the counting of a chain of input pulses. The circuit employs a series of direct connected bistable counting stages simultaneously pulsed by each input pulse and a delay means connected between each of the stages. Each bistable stage has two d-c operative states, which stage, when in its initial state, prevents the next succeeding stage from changing its condition when the latter stage is pulsed. Since the delay circuits between the stages prevents the immediate decay of the d-c state of each stage when the stages are pulsed, only one stage will change its state for each input pulse, thereby providing progressive stage-by-stage counting. (AEC)

  13. Short-Term Storage of Platelet-Rich Plasma at Room Temperature Does Not Affect Growth Factor or Catabolic Cytokine Concentration.

    PubMed

    Wilson, Brooke H; Cole, Brian J; Goodale, Margaret B; Fortier, Lisa A

    2018-04-01

    The aim of this study was to provide clinical recommendations about the use of platelet-rich plasma (PRP) that was subjected to short-term storage at room temperature. We determined bioactive growth factor and cytokine concentrations as indicators of platelet and white blood cell degranulation in blood and PRP. Additionally, this study sought to validate the use of manual, direct smear analysis as an alternative to automated methods for platelet quantification in PRP. Blood was used to generate low-leukocyte PRP (Llo PRP) or high-leukocyte PRP (Lhi PRP). Blood was either processed immediately or kept at room temperature for 2 or 4 hours prior to generation of PRP, which was then held at room temperature for 0, 1, 2, or 4 hours. Subsequently, bioactive transforming growth factor beta-1 and matrix metalloproteinase-9 were measured by ELISA (enzyme-linked immunosorbent assay). Manual and automated platelet counts were performed on all blood and PRP samples. There were no differences in growth factor or cytokine concentration when blood or Llo PRP or Lhi PRP was retained at room temperature for up to 4 hours. Manual, direct smear analysis for platelet quantification was not different from the use of automated machine counting for PRP samples, but in the starting blood samples, manual platelet counts were significantly higher than those generated using automated technology. When there is a delay of up to 4 hours in the generation of PRP from blood or in the application of PRP to the patient, bioactive growth factor and cytokine concentrations remain stable in both blood and PRP. A manual direct counting method is a simple, cost-effective, and valid method to measure the contents of the PRP product being delivered to the patient.

  14. Circulating endothelial progenitor cells in obese children and adolescents.

    PubMed

    Pires, António; Martins, Paula; Paiva, Artur; Pereira, Ana Margarida; Marques, Margarida; Castela, Eduardo; Sena, Cristina; Seiça, Raquel

    2015-01-01

    This study aimed to investigate the relationship between circulating endothelial progenitor cell count and endothelial activation in a pediatric population with obesity. Observational and transversal study, including 120 children and adolescents with primary obesity of both sexes, aged 6-17 years, who were recruited at this Cardiovascular Risk Clinic. The control group was made up of 41 children and adolescents with normal body mass index. The variables analyzed were: age, gender, body mass index, systolic and diastolic blood pressure, high-sensitivity C-reactive protein, lipid profile, leptin, adiponectin, homeostasis model assessment-insulin resistance, monocyte chemoattractant protein-1, E-selectin, asymmetric dimethylarginine and circulating progenitor endothelial cell count. Insulin resistance was correlated to asymmetric dimethylarginine (ρ=0.340; p=0.003), which was directly, but weakly correlated to E-selectin (ρ=0.252; p=0.046). High sensitivity C-reactive protein was not found to be correlated to markers of endothelial activation. Systolic blood pressure was directly correlated to body mass index (ρ=0.471; p<0.001) and the homeostasis model assessment-insulin resistance (ρ=0.230; p=0.012), and inversely correlated to adiponectin (ρ=-0.331; p<0.001) and high-density lipoprotein cholesterol (ρ=-0.319; p<0.001). Circulating endothelial progenitor cell count was directly, but weakly correlated, to body mass index (r=0.211; p=0.016), leptin (ρ=0.245; p=0.006), triglyceride levels (r=0.241; p=0.031), and E-selectin (ρ=0.297; p=0.004). Circulating endothelial progenitor cell count is elevated in obese children and adolescents with evidence of endothelial activation, suggesting that, during infancy, endothelial repairing mechanisms are present in the context of endothelial activation. Copyright © 2015 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  15. Excreta Sampling as an Alternative to In Vivo Measurements at the Hanford Site.

    PubMed

    Carbaugh, Eugene H; Antonio, Cheryl L; Lynch, Timothy P

    2015-08-01

    The capabilities of indirect radiobioassay by urine and fecal sample analysis were compared with the direct radiobioassay methods of whole body counting and lung counting for the most common radionuclides and inhalation exposure scenarios encountered by Hanford workers. Radionuclides addressed by in vivo measurement included 137Cs, 60Co, 154Eu, and 241Am as an indicator for plutonium mixtures. The same radionuclides were addressed using gamma energy analysis of urine samples, augmented by radiochemistry and alpha spectrometry methods for plutonium in urine and fecal samples. It was concluded that in vivo whole body counting and lung counting capability should be maintained at the Hanford Site for the foreseeable future, however, urine and fecal sample analysis could provide adequate, though degraded, monitoring capability for workers as a short-term alternative, should in vivo capability be lost due to planned or unplanned circumstances.

  16. Waveguide integrated low noise NbTiN nanowire single-photon detectors with milli-Hz dark count rate

    PubMed Central

    Schuck, Carsten; Pernice, Wolfram H. P.; Tang, Hong X.

    2013-01-01

    Superconducting nanowire single-photon detectors are an ideal match for integrated quantum photonic circuits due to their high detection efficiency for telecom wavelength photons. Quantum optical technology also requires single-photon detection with low dark count rate and high timing accuracy. Here we present very low noise superconducting nanowire single-photon detectors based on NbTiN thin films patterned directly on top of Si3N4 waveguides. We systematically investigate a large variety of detector designs and characterize their detection noise performance. Milli-Hz dark count rates are demonstrated over the entire operating range of the nanowire detectors which also feature low timing jitter. The ultra-low dark count rate, in combination with the high detection efficiency inherent to our travelling wave detector geometry, gives rise to a measured noise equivalent power at the 10−20 W/Hz1/2 level. PMID:23714696

  17. Standardization of Ga-68 by coincidence measurements, liquid scintillation counting and 4πγ counting.

    PubMed

    Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto

    2012-09-01

    The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.

  18. In situ detection of warfarin using time-correlated single-photon counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rosengren, Annika M.; Karlsson, Bjoern C.G.; Naeslund, Inga

    Highlights: {yields} Direct in situ measurement of specific isomeric forms of the anticoagulant warfarin. {yields} TCSPC spectroscopy in conjunction with synthetic Sudlow I binding site receptors. {yields} Development of sensor principle for use in clinical and environmental monitoring. -- Abstract: Here we report on a novel method for the direct in situ measurement of specific isomeric forms of the anticoagulant warfarin using time correlated single-photon counting (TCSPC) spectroscopy in conjunction with synthetic Sudlow I binding site receptors. The method is highly robust over the clinically significant concentration range, and demonstrates the potential of the binding site mimics in conjunction withmore » the spectroscopic strategy employed here for the determination of this important pharmaceutical in clinical or even environmental samples.« less

  19. A removal model for estimating detection probabilities from point-count surveys

    USGS Publications Warehouse

    Farnsworth, G.L.; Pollock, K.H.; Nichols, J.D.; Simons, T.R.; Hines, J.E.; Sauer, J.R.

    2002-01-01

    Use of point-count surveys is a popular method for collecting data on abundance and distribution of birds. However, analyses of such data often ignore potential differences in detection probability. We adapted a removal model to directly estimate detection probability during point-count surveys. The model assumes that singing frequency is a major factor influencing probability of detection when birds are surveyed using point counts. This may be appropriate for surveys in which most detections are by sound. The model requires counts to be divided into several time intervals. Point counts are often conducted for 10 min, where the number of birds recorded is divided into those first observed in the first 3 min, the subsequent 2 min, and the last 5 min. We developed a maximum-likelihood estimator for the detectability of birds recorded during counts divided into those intervals. This technique can easily be adapted to point counts divided into intervals of any length. We applied this method to unlimited-radius counts conducted in Great Smoky Mountains National Park. We used model selection criteria to identify whether detection probabilities varied among species, throughout the morning, throughout the season, and among different observers. We found differences in detection probability among species. Species that sing frequently such as Winter Wren (Troglodytes troglodytes) and Acadian Flycatcher (Empidonax virescens) had high detection probabilities (∼90%) and species that call infrequently such as Pileated Woodpecker (Dryocopus pileatus) had low detection probability (36%). We also found detection probabilities varied with the time of day for some species (e.g. thrushes) and between observers for other species. We used the same approach to estimate detection probability and density for a subset of the observations with limited-radius point counts.

  20. Integrated Arrival and Departure Schedule Optimization Under Uncertainty

    NASA Technical Reports Server (NTRS)

    Xue, Min; Zelinski, Shannon

    2014-01-01

    In terminal airspace, integrating arrivals and departures with shared waypoints provides the potential of improving operational efficiency by allowing direct routes when possible. Incorporating stochastic evaluation as a post-analysis process of deterministic optimization, and imposing a safety buffer in deterministic optimization, are two ways to learn and alleviate the impact of uncertainty and to avoid unexpected outcomes. This work presents a third and direct way to take uncertainty into consideration during the optimization. The impact of uncertainty was incorporated into cost evaluations when searching for the optimal solutions. The controller intervention count was computed using a heuristic model and served as another stochastic cost besides total delay. Costs under uncertainty were evaluated using Monte Carlo simulations. The Pareto fronts that contain a set of solutions were identified and the trade-off between delays and controller intervention count was shown. Solutions that shared similar delays but had different intervention counts were investigated. The results showed that optimization under uncertainty could identify compromise solutions on Pareto fonts, which is better than deterministic optimization with extra safety buffers. It helps decision-makers reduce controller intervention while achieving low delays.

  1. Direct Determination of Activities for Microorganisms of Chesapeake Bay Populations

    PubMed Central

    Tabor, Paul S.; Neihof, Rex A.

    1984-01-01

    We used three methods in determination of the metabolically active individual microorganisms for Chesapeake Bay surface and near-bottom populations over a period of a year. Synthetically active bacteria were recognized as enlarged cells in samples amended with nalidixic acid and yeast extract and incubated for 6 h. Microorganisms with active electron transport systems were identified by the reduction of a tetrazolium salt electron acceptor. Microorganisms active in uptake of amino acids, thymidine, and acetate were determined by microautoradiography. In conjunction with enumeration of active organisms, a total direct count was made for each sample preparation by epifluorescence microscopy. For the majority of samples, numbers of amino acid uptake-active organisms were greater than numbers of organisms determined to be active by other direct measurements. Within a sample, the numbers of uptake-active organisms (amino acids or thymidine) and electron transport system-active organisms were significantly different for 68% of the samples. Numbers of synthetically active bacteria were generally less than numbers determined by the other direct activity measurements. The distribution of total counts in the 11 samplings showed a seasonal pattern, with significant dependence on in situ water temperature, increasing from March to September and then decreasing through February. Synthetically active bacteria and amino acid uptake-active organisms showed a significant dependence on in situ temperature, independent of the function of temperature on total counts. Numbers of active organisms determined by at least one of the methods used exceeded 25% of the total population of all samplings, and from June through September, >85% of the total population was found to be active by at least one direct activity measurement. Thus, active rather than dormant organisms compose a major portion of the microbial population in this region of Chesapeake Bay. PMID:16346659

  2. Direct determination of activities for microorganisms of chesapeake bay populations.

    PubMed

    Tabor, P S; Neihof, R A

    1984-11-01

    We used three methods in determination of the metabolically active individual microorganisms for Chesapeake Bay surface and near-bottom populations over a period of a year. Synthetically active bacteria were recognized as enlarged cells in samples amended with nalidixic acid and yeast extract and incubated for 6 h. Microorganisms with active electron transport systems were identified by the reduction of a tetrazolium salt electron acceptor. Microorganisms active in uptake of amino acids, thymidine, and acetate were determined by microautoradiography. In conjunction with enumeration of active organisms, a total direct count was made for each sample preparation by epifluorescence microscopy. For the majority of samples, numbers of amino acid uptake-active organisms were greater than numbers of organisms determined to be active by other direct measurements. Within a sample, the numbers of uptake-active organisms (amino acids or thymidine) and electron transport system-active organisms were significantly different for 68% of the samples. Numbers of synthetically active bacteria were generally less than numbers determined by the other direct activity measurements. The distribution of total counts in the 11 samplings showed a seasonal pattern, with significant dependence on in situ water temperature, increasing from March to September and then decreasing through February. Synthetically active bacteria and amino acid uptake-active organisms showed a significant dependence on in situ temperature, independent of the function of temperature on total counts. Numbers of active organisms determined by at least one of the methods used exceeded 25% of the total population of all samplings, and from June through September, >85% of the total population was found to be active by at least one direct activity measurement. Thus, active rather than dormant organisms compose a major portion of the microbial population in this region of Chesapeake Bay.

  3. Comparison of a new inorganic membrane filter (Anopore) with a track-etched polycarbonate membrane filter (Nuclepore) for direct counting of bacteria.

    PubMed Central

    Jones, S E; Ditner, S A; Freeman, C; Whitaker, C J; Lock, M A

    1989-01-01

    Bacterial counts obtained by using a new Anopore inorganic membrane filter were 21 to 33% higher than those obtained by using a Nuclepore polycarbonate membrane filter. In addition, the inorganic filter had higher flow rates, permitting lower vacuum pressures to be used, while the intrinsically flat, rigid surface resulted in easier focusing and sharp definition of bacteria across the whole field of view. Images PMID:2655539

  4. The dermatoglyphic characteristics of transsexuals: is there evidence for an organizing effect of sex hormones.

    PubMed

    Slabbekoorn, D; van Goozen, S H; Sanders, G; Gooren, L J; Cohen-Kettenis, P T

    2000-05-01

    It has been proposed that gender identity and sexual orientation are influenced by the prenatal sex steroid milieu. Human dermatoglyphics and brain asymmetry have also been ascribed to prenatal hormone levels. This study investigated dermatoglyphics (total ridge count and finger ridge asymmetry) in 184 male-to-female transsexuals and 110 female-to-male transsexuals. In a subgroup, the relationship between dermatoglyphic asymmetry and spatial ability was tested. All investigations included controls. For all subjects hand preference and sexual orientation were noted. We hypothesized that the dermatoglyphics of male-to-female transsexuals would show similarities with control women and those of female-to-male transsexuals with control men. Our results showed a trend for a sex difference in total ridge count (P<.1) between genetic males and females, but no difference in directional asymmetry was found. Contrary to our expectations, the total ridge count and finger ridge asymmetry of transsexuals were similar to their genetic sex controls. Additionally, directional asymmetry was neither related to sexual orientation, nor to different aspects of spatial ability. In conclusion, we were unable to demonstrate that our chosen dermatoglyphic variables, total ridge count and finger ridge asymmetry are related to gender identity and sexual orientation in adult transsexuals. Hence, we found no support for a prenatal hormonal influence on these characteristics, at least insofar as dermatoglyphics may be regarded as a biological marker of organizing hormonal effects.

  5. Movements of radio-marked California Ridgway's rails during monitoring surveys: Implications for population monitoring

    USGS Publications Warehouse

    Bui, Thuy-Vy D.; Takekawa, John Y.; Overton, Cory T.; Schultz, Emily R.; Hull, Joshua M.; Casazza, Michael L.

    2015-01-01

    The California Ridgway's rail Rallus obsoletus obsoletus (hereafter California rail) is a secretive marsh bird endemic to tidal marshes in the San Francisco Bay (hereafter bay) of California. The California rail has undergone significant range contraction and population declines due to a variety of factors, including predation and the degradation and loss of habitat. Call-count surveys, which include call playbacks, based on the standardized North American marsh bird monitoring protocol have been conducted throughout the bay since 2005 to monitor population size and distribution of the California rail. However, call-count surveys are difficult to evaluate for efficacy or accuracy. To measure the accuracy of call-count surveys and investigate whether radio-marked California rails moved in response to call-count surveys, we compared locations of radio-marked California rails collected at frequent intervals (15 min) to California rail detections recorded during call-count surveys conducted over the same time periods. Overall, 60% of radio-marked California rails within 200 m of observers were not detected during call-count surveys. Movements of radio-marked California rails showed no directional bias (P = 0.92) irrespective of whether or not playbacks of five marsh bird species (including the California rail) were broadcast from listening stations. Our findings suggest that playbacks of rail vocalizations do not consistently influence California rail movements during surveys. However, call-count surveys may underestimate California rail presence; therefore, caution should be used when relating raw numbers of call-count detections to population abundance.

  6. The NuSTAR Extragalactic Surveys: The Number Counts of Active Galactic Nuclei and The Resolved Fraction of The Cosmic X-Ray Background

    DOE PAGES

    Harrison, F. A.; Aird, J.; Civano, F.; ...

    2016-11-07

    Here, we present the 3–8 keV and 8–24 keV number counts of active galactic nuclei (AGNs) identified in the Nuclear Spectroscopic Telescope Array (NuSTAR) extragalactic surveys. NuSTAR has now resolved 33%–39% of the X-ray background in the 8–24 keV band, directly identifying AGNs with obscuring columns up tomore » $$\\sim {10}^{25}\\,{\\mathrm{cm}}^{-2}$$. In the softer 3–8 keV band the number counts are in general agreement with those measured by XMM-Newton and Chandra over the flux range $$5\\times {10}^{-15}\\,\\lesssim $$ S(3–8 keV)/$$\\mathrm{erg}\\,{{\\rm{s}}}^{-1}\\,{\\mathrm{cm}}^{-2}\\,\\lesssim \\,{10}^{-12}$$ probed by NuSTAR. In the hard 8–24 keV band NuSTAR probes fluxes over the range $$2\\times {10}^{-14}\\,\\lesssim $$ S(8–24 keV)/$$\\mathrm{erg}\\,{{\\rm{s}}}^{-1}\\,{\\mathrm{cm}}^{-2}\\,\\lesssim \\,{10}^{-12}$$, a factor ~100 fainter than previous measurements. The 8–24 keV number counts match predictions from AGN population synthesis models, directly confirming the existence of a population of obscured and/or hard X-ray sources inferred from the shape of the integrated cosmic X-ray background. The measured NuSTAR counts lie significantly above simple extrapolation with a Euclidian slope to low flux of the Swift/BAT 15–55 keV number counts measured at higher fluxes (S(15–55 keV) gsim 10-11 $$\\mathrm{erg}\\,{{\\rm{s}}}^{-1}\\,{\\mathrm{cm}}^{-2}$$), reflecting the evolution of the AGN population between the Swift/BAT local ($$z\\lt 0.1$$) sample and NuSTAR's $$z\\sim 1$$ sample. CXB synthesis models, which account for AGN evolution, lie above the Swift/BAT measurements, suggesting that they do not fully capture the evolution of obscured AGNs at low redshifts.« less

  7. NICER observations of MAXI J1820+070 suggest a rapidly-brightening black hole X-ray binary in the hard state

    NASA Astrophysics Data System (ADS)

    Uttley, P.; Gendreau, K.; Markwardt, C.; Strohmayer, T. E.; Bult, P.; Arzoumanian, Z.; Pottschmidt, K.; Ray, P. S.; Remillard, R.; Pasham, D.; Steiner, J.; Neilsen, J.; Homan, J.; Miller, J. M.; Iwakiri, W.; Fabian, A. C.

    2018-03-01

    NICER observed the new X-ray transient MAXI J1820+070 (ATel #11399, #11400, #11403, #11404, #11406, #11418, #11420, #11421) on multiple occasions from 2018 March 12 to 14. & nbsp;During this time the source brightened rapidly, from a total NICER mean count rate of 880 count/s on March 12 to 2800 count/s by March 14 17:00 & nbsp;UTC, corresponding to a change in 2-10 keV modelled flux (see below) from 1.9E-9 to 5E-9 erg cm-2 s-1. & nbsp; The broadband X-ray spectrum is absorbed by a low column density (fitting the model given below, we obtain 1.5E21 cm-2), in keeping with the low Galactic column in the direction of the source (ATel #11418; Dickey & Lockman, 1990, ARAA, 28, 215; Kalberla et al. 2005, A &A, 440, 775) and consists of a hard power-law component with weak reflection features (broad iron line and narrow 6.4 keV line core) and an additional soft X-ray component.

  8. A Novel Sensor Based on a Single-Pixel Microwave Radiometer for Warm Object Counting: Concept Validation and IoT Perspectives

    PubMed Central

    Alimenti, Federico; Bonafoni, Stefania; Roselli, Luca

    2017-01-01

    Controlled measurements by a low-cost single-pixel microwave radiometer operating at 12.65 GHz were carried out to assess the detection and counting capability for targets warmer than the surroundings. The adopted reference test targets were pre-warmed water and oil; and a hand, both naked and wearing a glove. The results showed the reliability of microwave radiometry for counting operations under controlled conditions, and its effectiveness at detecting even warm targets masked by unheated dielectric layers. An electromagnetic model describing the scenario sensed by the radiometer antenna is proposed, and comparison with the experimental observations shows a good agreement. The measurements prove that reliable counting is enabled by an antenna temperature increment, for each target sample added, of around 1 K. Starting from this value, an analysis of the antenna filling factor was performed to provide an instrument useful for evaluating real applicability in many practical situations. This study also allows the direct people counting problem to be addressed, providing preliminary operational indications, reference numbers and experimental validation. PMID:28613264

  9. Pulse pileup statistics for energy discriminating photon counting x-ray detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Wang, Adam S.; Harrison, Daniel; Lobastov, Vladimir

    Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N{sub 0}, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analyticallymore » for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramer-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20%N{sub 0}, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging.« less

  10. The analysis of some indices of immune response, DNA repair, and micronuclei content in cells from tick-borne encephalitis patients.

    PubMed

    Ilyinskikh, N N; Zagromov, E J; Lepekhin, A V

    1990-12-01

    Patients with tick-borne encephalitis (TBE) had higher counts of red blood cells (RBC) with micronuclei. The majority of patients revealed decreased capacity of blood lymphoid cells for DNA repair except those with a 2-wave pattern of the course of disease; in the latter, the DNA repair was significantly higher than in healthy donors. Patients with TBE revealed lower T-lymphocyte counts due to a decrease in the amount of T-helper cells (the level of T-suppressors was elevated). The intensity of antibody production against TBE virus was significantly enhanced by termination of disease in the majority of patients. The count of natural killer cells was decreased, particularly at the initial stage of disease. At the time of admission to hospital the counts of RBC with micronuclei and of T-helper cells were in reverse proportion. At the terminal stage of disease the same correlation was noted between RBC counts with micronuclei and the antibody level. At the onset of disease a direct correlation was noted between DNA repair and B-lymphocyte and T-helper counts. At the final stage of disease the reverse correlation between the activity of DNA-repair systems and T-suppressor counts was registered. Three months after discharge from hospital, the indices of micronuclear test, natural killer cell activity, and DNA repair returned to normal.

  11. 45 CFR 261.32 - How many hours must work-eligible individuals participate for the family to count in the...

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ...-the-job training; job search and job readiness assistance; community service programs; vocational educational training; and providing child care services to an individual who is participating in a community... participation: job skills training directly related to employment; education directly related to employment; and...

  12. A combination of direct viable count and fluorescence in situ hybridization for specific enumeration of viable Lactobacillus delbrueckii subsp.bulgaricus and Streptococcus thermophilus.

    PubMed

    García-Hernández, J; Moreno, Y; Amorocho, C M; Hernández, M

    2012-03-01

    We have developed a direct viable count (DVC)-FISH procedure for quickly and easily discriminating between viable and nonviable cells of Lactobacillus delbrueckii subsp. bulgaricus and Streptococcus thermophilus strains, the traditional yogurt bacteria. direct viable count method has been modified and adapted for Lact. delbrueckii subsp. bulgaricus and Strep. thermophilus analysis by testing different times of incubation and concentrations of DNA-gyrase inhibitors. DVC procedure has been combined with fluorescent in situ hybridization (FISH) for the specific detection of viable cells of both bacteria with specific rRNA oligonucleotide probes (DVC-FISH). Of the four antibiotics tested (novobiocin, nalidixic acid, pipemidic acid and ciprofloxacin), novobiocin was the most effective for DVC method and the optimum incubation time was 7 h for both bacteria. The number of viable cells was obtained by the enumeration of specific hybridized cells that were elongated at least twice their original length for Lactobacillus and twice their original size for Streptococcus. This technique was successfully applied to detect viable cells in inoculated faeces. Results showed that this DVC-FISH procedure is a quick and culture-independent useful method to specifically detect viable Lact. delbrueckii subsp. bulgaricus and Strep. thermophilus in different samples, being applied for the first time to lactic acid bacteria. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.

  13. Direct Parametric Reconstruction With Joint Motion Estimation/Correction for Dynamic Brain PET Data.

    PubMed

    Jiao, Jieqing; Bousse, Alexandre; Thielemans, Kris; Burgos, Ninon; Weston, Philip S J; Schott, Jonathan M; Atkinson, David; Arridge, Simon R; Hutton, Brian F; Markiewicz, Pawel; Ourselin, Sebastien

    2017-01-01

    Direct reconstruction of parametric images from raw photon counts has been shown to improve the quantitative analysis of dynamic positron emission tomography (PET) data. However it suffers from subject motion which is inevitable during the typical acquisition time of 1-2 hours. In this work we propose a framework to jointly estimate subject head motion and reconstruct the motion-corrected parametric images directly from raw PET data, so that the effects of distorted tissue-to-voxel mapping due to subject motion can be reduced in reconstructing the parametric images with motion-compensated attenuation correction and spatially aligned temporal PET data. The proposed approach is formulated within the maximum likelihood framework, and efficient solutions are derived for estimating subject motion and kinetic parameters from raw PET photon count data. Results from evaluations on simulated [ 11 C]raclopride data using the Zubal brain phantom and real clinical [ 18 F]florbetapir data of a patient with Alzheimer's disease show that the proposed joint direct parametric reconstruction motion correction approach can improve the accuracy of quantifying dynamic PET data with large subject motion.

  14. Influence of wind on daily airborne pollen counts in Catalonia (NE Iberian Peninsula)

    NASA Astrophysics Data System (ADS)

    tareq Majeed, Husam; Periago, Cristina; Alarcón, Marta; De Linares, Concepción; Belmonte, Jordina

    2016-04-01

    The aim of this study is to analize the influence of wind (speed and direction) on the daily airborne pollen counts recorded in Catalonia (NE Iberian Peninsula) of 21 pollen taxa recorded at 6 aerobiological stations: Barcelona, Bellaterra, Girona, Lleida Manresa, and Tarragona for the period 2004-2014. The taxa studied are Alnus, Betula, Castanea, Cupressaceae, Fagus, Fraxinus, Olea, Pinus, Platanus, total Quercus, Quercus deciduous type, Quercus evergreen type, Ulmus, Corylus, Pistacia, Artemisia, Chenopodiaceae/Amaranthaceae, Plantago, Poaceae, Polygonaceae, and Urticaceae. The mean daily wind direction was divided into 8 sectors: N, NE, E, SE, S, SW, W and NW. For each sector, the correlation between the daily pollen concentrations and wind speed using Spearman's rank correlation coefficient was computed and compared with the wind rose charts. The results showed that Tarragona was the station with more significant correlations followed by Bellaterra, Lleida and Manresa. On the other hand, Artemisia was the most correlated taxon with mainly negative values, and Fagus was the least. The W wind direction showed the largest number of significant correlations, mostly positive, while the N direction was the least and negatively correlated.

  15. Nutritional status and CD4 cell counts in patients with HIV/AIDS receiving antiretroviral therapy.

    PubMed

    Santos, Ana Célia Oliveira dos; Almeida, Ana Maria Rampeloti

    2013-01-01

    Even with current highly active antiretroviral therapy, individuals with AIDS continue to exhibit important nutritional deficits and reduced levels of albumin and hemoglobin, which may be directly related to their cluster of differentiation 4 (CD4) cell counts. The aim of this study was to characterize the nutritional status of individuals with human immunodeficiency virus/acquired immunodeficiency syndrome (HIV/AIDS) and relate the findings to the albumin level, hemoglobin level and CD4 cell count. Patients over 20 years of age with AIDS who were hospitalized in a university hospital and were receiving antiretroviral therapy were studied with regard to clinical, anthropometric, biochemical and sociodemographic characteristics. Body mass index, percentage of weight loss, arm circumference, triceps skinfold and arm muscle circumference were analyzed. Data on albumin, hemoglobin, hematocrit and CD4 cell count were obtained from patient charts. Statistical analysis was performed using Fisher's exact test, Student's t-test for independent variables and the Mann-Whitney U-test. The level of significance was set to 0.05 (α = 5%). Statistical analysis was performed using Statistical Package for the Social Sciences (SPSS) 17.0 software for Windows. Of the 50 patients evaluated, 70% were male. The prevalence of malnutrition was higher when the definition was based on arm circumference and triceps skinfold measurement. The concentrations of all biochemical variables were significantly lower among patients with a body mass index of less than 18.5kg/m2. The CD4 cell count, albumin, hemoglobin and hematocrit anthropometric measures were directly related to each other. These findings underscore the importance of nutritional follow-up for underweight patients with AIDS, as nutritional status proved to be related to important biochemical alterations.

  16. Universal Pin Electronics.

    DTIC Science & Technology

    1982-11-03

    define the maximum count for the pattern defined by the first 3 bits. Since there are 11 bits involved it is possible to define patterns up to 2048 ...applied to the UUT directly through the driver for any count up to 2048 . Any one of the 7 clocks may be selected under program control and applied to any...one ievel for the driver ( VDI ), the logic zero level for the driver (VDO), the logic one level for the receiver (VRl), and the logic zero level for the

  17. Correlation of total serum immunoglobulin E level, sputum, and peripheral eosinophil count in assessing the clinical severity in bronchial asthma.

    PubMed

    Kumar, Roshan M; Pajanivel, R; Koteeswaran, G; Menon, Surendra K; Charles, Pravin Mv

    2017-01-01

    Asthma is a chronic inflammatory disorder of the airway with involvement of various cellular populations and release of many inflammatory mediators. Eosinophils and serum immunoglobulin E (IgE) are considered a good marker of airway inflammation in asthma. The correlation of clinical assessment with various markers of airway inflammation in asthma is not well established in the Indian population. This study aims to study the correlation of serum IgE, sputum eosinophil count, and peripheral eosinophil count with clinical severity of Asthma. This is a cross-sectional study involving 76 stable asthmatic patients of 18-60 years of age attending the pulmonary medicine OPD. Spirometry measured at baseline. Participants were categorized according to the GINA criteria based on clinical symptoms and pulmonary function test. Blood samples were collected for peripheral eosinophil count, serum IgE levels, and sputum samples for eosinophil count. All three parameters were compared with severity of asthma. The correlation of sputum eosinophil count, peripheral eosinophil count, and serum IgE with severity of asthma was analyzed by Pearson's Chi-square test, Fisher's exact test, and the correlation coefficient was reported together with standard error of the estimate. The mean age of patients in our study was 37.42 years and 56.6% were male. There was a significant inverse correlation between serum IgE levels and predicted forced expiratory volume 1 s (FEV1). Sputum eosinophilia was significantly seen in severe persistent asthma patients (19.7%). There was a significant inverse correlation between sputum eosinophil count and predicted FEV1and forced vital capacity. We also found there was a significant association between peripheral eosinophil count, sputum eosinophil count, and elevated serum IgE (g100 IU/mL) with severe persistent asthma. The assessment of sputum eosinophil count is simple, inexpensive, noninvasive, and direct measurement of airway inflammation. It could be the preferred method in monitoring airway inflammation and guided management in day-to-day practice.

  18. Photon counting photodiode array detector for far ultraviolet (FUV) astronomy

    NASA Technical Reports Server (NTRS)

    Hartig, G. F.; Moos, H. W.; Pembroke, R.; Bowers, C.

    1982-01-01

    A compact, stable, single-stage intensified photodiode array detector designed for photon-counting, far ultraviolet astronomy applications employs a saturable, 'C'-type MCP (Galileo S. MCP 25-25) to produce high gain pulses with a narrowly peaked pulse height distribution. The P-20 output phosphor exhibits a very short decay time, due to the high current density of the electron pulses. This intensifier is being coupled to a self-scanning linear photodiode array which has a fiber optic input window which allows direct, rigid mechanical coupling with minimal light loss. The array was scanned at a 250 KHz pixel rate. The detector exhibits more than adequate signal-to-noise ratio for pulse counting and event location. Previously announced in STAR as N82-19118

  19. Performance Equivalence and Validation of the Soleris Automated System for Quantitative Microbial Content Testing Using Pure Suspension Cultures.

    PubMed

    Limberg, Brian J; Johnstone, Kevin; Filloon, Thomas; Catrenich, Carl

    2016-09-01

    Using United States Pharmacopeia-National Formulary (USP-NF) general method <1223> guidance, the Soleris(®) automated system and reagents (Nonfermenting Total Viable Count for bacteria and Direct Yeast and Mold for yeast and mold) were validated, using a performance equivalence approach, as an alternative to plate counting for total microbial content analysis using five representative microbes: Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa, Candida albicans, and Aspergillus brasiliensis. Detection times (DTs) in the alternative automated system were linearly correlated to CFU/sample (R(2) = 0.94-0.97) with ≥70% accuracy per USP General Chapter <1223> guidance. The LOD and LOQ of the automated system were statistically similar to the traditional plate count method. This system was significantly more precise than plate counting (RSD 1.2-2.9% for DT, 7.8-40.6% for plate counts), was statistically comparable to plate counting with respect to variations in analyst, vial lots, and instruments, and was robust when variations in the operating detection thresholds (dTs; ±2 units) were used. The automated system produced accurate results, was more precise and less labor-intensive, and met or exceeded criteria for a valid alternative quantitative method, consistent with USP-NF general method <1223> guidance.

  20. The use of flow cytometry to accurately ascertain total and viable counts of Lactobacillus rhamnosus in chocolate.

    PubMed

    Raymond, Yves; Champagne, Claude P

    2015-04-01

    The goals of this study were to evaluate the precision and accuracy of flow cytometry (FC) methodologies in the evaluation of populations of probiotic bacteria (Lactobacillus rhamnosus R0011) in two commercial dried forms, and ascertain the challenges in enumerating them in a chocolate matrix. FC analyses of total (FC(T)) and viable (FC(V)) counts in liquid or dried cultures were almost two times more precise (reproducible) than traditional direct microscopic counts (DCM) or colony forming units (CFU). With FC, it was possible to ascertain low levels of dead cells (FC(D)) in fresh cultures, which is not possible with traditional CFU and DMC methodologies. There was no interference of chocolate solids on FC counts of probiotics when inoculation was above 10(7) bacteria per g. Addition of probiotics in chocolate at 40 °C resulted in a 37% loss in viable cells. Blending of the probiotic powder into chocolate was not uniform which raised a concern that the precision of viable counts could suffer. FCT data can serve to identify the correct inoculation level of a sample, and viable counts (FCV or CFU) can subsequently be better interpreted. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  1. Optimized collectives using a DMA on a parallel computer

    DOEpatents

    Chen, Dong [Croton On Hudson, NY; Gabor, Dozsa [Ardsley, NY; Giampapa, Mark E [Irvington, NY; Heidelberger,; Phillip, [Cortlandt Manor, NY

    2011-02-08

    Optimizing collective operations using direct memory access controller on a parallel computer, in one aspect, may comprise establishing a byte counter associated with a direct memory access controller for each submessage in a message. The byte counter includes at least a base address of memory and a byte count associated with a submessage. A byte counter associated with a submessage is monitored to determine whether at least a block of data of the submessage has been received. The block of data has a predetermined size, for example, a number of bytes. The block is processed when the block has been fully received, for example, when the byte count indicates all bytes of the block have been received. The monitoring and processing may continue for all blocks in all submessages in the message.

  2. Renormalization of a tensorial field theory on the homogeneous space SU(2)/U(1)

    NASA Astrophysics Data System (ADS)

    Lahoche, Vincent; Oriti, Daniele

    2017-01-01

    We study the renormalization of a general field theory on the homogeneous space (SU(2)/ ≤ft. U(1)\\right){{}× d} with tensorial interaction and gauge invariance under the diagonal action of SU(2). We derive the power counting for arbitrary d. For the case d  =  4, we prove perturbative renormalizability to all orders via multi-scale analysis, study both the renormalized and effective perturbation series, and establish the asymptotic freedom of the model. We also outline a general power counting for the homogeneous space {{≤ft(SO(D)/SO(D-1)\\right)}× d} , of direct interest for quantum gravity models in arbitrary dimension, and point out the obstructions to the direct generalization of our results to these cases.

  3. From quarks to nucleons in dark matter direct detection

    NASA Astrophysics Data System (ADS)

    Bishara, Fady; Brod, Joachim; Grinstein, Benjamin; Zupan, Jure

    2017-11-01

    We provide expressions for the nonperturbative matching of the effective field theory describing dark matter interactions with quarks and gluons to the effective theory of nonrelativistic dark matter interacting with nonrelativistic nucleons. We give expressions of leading and subleading order in chiral counting. In general, a single partonic operator matches onto several nonrelativistic operators already at leading order in chiral counting. Keeping only one operator at the time in the nonrelativistic effective theory thus does not properly describe the scattering in direct detection. The matching of the axial-axial partonic level operator, as well as the matching of the operators coupling DM to the QCD anomaly term, include naively momentum suppressed terms. However, these are still of leading chiral order due to pion poles and can be numerically important.

  4. Development of an S-band cavity Beam Position Monitor for ATF2

    NASA Astrophysics Data System (ADS)

    Heo, A.; Kim, E.-S.; Kim, H.; Son, D.; Honda, Y.; Tauchi, T.

    2013-04-01

    We have developed an S-band cavity Beam Position Monitor (BPM) in order to measure the position of an electron beam in the final focus area at ATF2, which is the test facility for the final focus design for the International Linear Collider (ILC). The lattice of the ILC Beam Delivery System (BDS) has been modified, requiring a larger physical aperture of 40 mm in the final focus area. The beam orbit measurement in this area is now covered with high resolution S-Band cavity BPMs. In this paper we summarize the design of the cavity BPM and the first experimental results. The calibration slopes were measured as 0.87 counts/μm in the x-coordinate direction and 1.16 counts/μm in the y-coordinate direction.

  5. Flow direction variations of low energy ions as measured by the ion electron sensor (IES) flying on board of Rosetta

    NASA Astrophysics Data System (ADS)

    Szegö, Karoly; Nemeth, Zoltan; Foldy, Lajos; Burch, James L.; Goldstein, Raymond; Mandt, Kathleen; Mokashi, Prachet; Broiles, Tom

    2015-04-01

    The Ion Electron Sensor (IES) simultaneously measures ions and electrons with two separate electrostatic plasma analyzers in the energy range of 4 eV- 22 keV for ions. The field of view is 90ox360o, with angular resolution 5ox45o for ions, with a sector containing the solar wind being further segmented to 5o × 5o. IES has operated continuously since early 2014. In the ion data a low energy (<50-100 eV) component is well separated from the higher energy ions. Here we analyze the arrival direction of this low energy component. The origin of these low energy ions is certainly the ionized component of the neutral gas emitted due to solar activity from comet 67P/Churiumov-Gerasimenko. The low energy component in general shows a 6h periodicity due to cometary rotation. The data show, however, that the arrival direction of the low energy ions is smeared both in azimuth and elevation, due possibly to the diverse mechanisms affecting these ions. One of these effects is the spacecraft potential (~-10V), which accelerates the ions towards the spacecraft omnidirectionally. To characterize the flow direction in azimuth-elevation, we have integrated over the lowest 8 energy channels using weighted energy: sum(counts * energy)/sum(counts); and considered only cases when the counts are above 30. When we apply higher cut for counts, the flow direction became more definite. For this analysis we use data files where the two neighbouring energy values and elevation values are collapsed; and the azimuthal resolution is 45o, that is the solar wind azimuthal segmentation is also collapsed. Here we use day 2014.09.11. as illustration. On that day a solar wind shock reached the spacecraft at about ~10 UT. After the shock transition the energy of the solar wind became higher, and after ~12 UT the flow direction of the solar wind fluctuated, sometimes by 35o. On this day Rosetta flew at about 29.3-29.6 km from the nucleus. In the azimuth-elevation plots summed over "weighted energy" (as defined above) we were able to identify two flow directions: one close to the anti-solar direction, and one perpendicular to it. The occurrence and variations of these directions are still under investigation. A possible cause of the acceleration of low energy ions along the solar wind might be that electrons produced by the ionization of neutrals are immediately picked up by the solar wind generating a polarization electric field that accelerates the ions. This effect is similar to the generation of ionospheric holes at Venus [Hartle and Grebowsky, Adv. Space Res., 4, 1995]. The acceleration perpendicular to the solar wind might be due to the v x B electric field. The variations of the low energy flow direction is analyzed in detail in the presentation.

  6. Scale-dependent associations of Band-tailed Pigeon counts at mineral sites

    USGS Publications Warehouse

    Overton, Cory T.; Casazza, Michael L.; Coates, Peter S.

    2010-01-01

    The abundance of Band-tailed Pigeons (Patagioenas fasciata monilis) has declined substantially from historic numbers along the Pacific Coast. Identification of patterns and causative factors of this decline are hampered because habitat use data are limited, and temporal and spatial variability patterns associated with population indices are not known. Furthermore, counts are influenced not only by pigeon abundance but also by rate of visitation to mineral sites, which may not be consistent. To address these issues, we conducted mineral site counts during 2001 and 2002 at 20 locations from 4 regions in the Pacific Northwest, including central Oregon and western Washington, USA, and British Columbia, Canada. We developed inference models that consisted of environmental factors and spatial characteristics at multiple spatial scales. Based on information theory, we compared models within a final set that included variables measured at 3 spatial scales (0.03 ha, 3.14 ha, and 7850 ha). Pigeon counts increased from central Oregon through northern Oregon and decreased into British Columbia. After accounting for this spatial pattern, we found that pigeon counts increased 12% ± 2.7 with a 10% increase in the amount of deciduous forested area within 100 m from a mineral site. Also, distance from the mineral site of interest to the nearest known mineral site was positively related to pigeon counts. These findings provide direction for future research focusing on understanding the relationships between indices of relative abundance and complete counts (censuses) of pigeon populations by identifying habitat characteristics that might influence visitation rates. Furthermore, our results suggest that spatial arrangement of mineral sites influences Band-tailed Pigeon counts and the populations which those counts represent.

  7. Zero-state Markov switching count-data models: an empirical assessment.

    PubMed

    Malyshkina, Nataliya V; Mannering, Fred L

    2010-01-01

    In this study, a two-state Markov switching count-data model is proposed as an alternative to zero-inflated models to account for the preponderance of zeros sometimes observed in transportation count data, such as the number of accidents occurring on a roadway segment over some period of time. For this accident-frequency case, zero-inflated models assume the existence of two states: one of the states is a zero-accident count state, which has accident probabilities that are so low that they cannot be statistically distinguished from zero, and the other state is a normal-count state, in which counts can be non-negative integers that are generated by some counting process, for example, a Poisson or negative binomial. While zero-inflated models have come under some criticism with regard to accident-frequency applications - one fact is undeniable - in many applications they provide a statistically superior fit to the data. The Markov switching approach we propose seeks to overcome some of the criticism associated with the zero-accident state of the zero-inflated model by allowing individual roadway segments to switch between zero and normal-count states over time. An important advantage of this Markov switching approach is that it allows for the direct statistical estimation of the specific roadway-segment state (i.e., zero-accident or normal-count state) whereas traditional zero-inflated models do not. To demonstrate the applicability of this approach, a two-state Markov switching negative binomial model (estimated with Bayesian inference) and standard zero-inflated negative binomial models are estimated using five-year accident frequencies on Indiana interstate highway segments. It is shown that the Markov switching model is a viable alternative and results in a superior statistical fit relative to the zero-inflated models.

  8. Consideraciones para la estimacion de abundancia de poblaciones de mamiferos. [Considerations for the estimation of abundance of mammal populations.

    USGS Publications Warehouse

    Walker, R.S.; Novare, A.J.; Nichols, J.D.

    2000-01-01

    Estimation of abundance of mammal populations is essential for monitoring programs and for many ecological investigations. The first step for any study of variation in mammal abundance over space or time is to define the objectives of the study and how and why abundance data are to be used. The data used to estimate abundance are count statistics in the form of counts of animals or their signs. There are two major sources of uncertainty that must be considered in the design of the study: spatial variation and the relationship between abundance and the count statistic. Spatial variation in the distribution of animals or signs may be taken into account with appropriate spatial sampling. Count statistics may be viewed as random variables, with the expected value of the count statistic equal to the true abundance of the population multiplied by a coefficient p. With direct counts, p represents the probability of detection or capture of individuals, and with indirect counts it represents the rate of production of the signs as well as their probability of detection. Comparisons of abundance using count statistics from different times or places assume that the p are the same for all times or places being compared (p= pi). In spite of considerable evidence that this assumption rarely holds true, it is commonly made in studies of mammal abundance, as when the minimum number alive or indices based on sign counts are used to compare abundance in different habitats or times. Alternatives to relying on this assumption are to calibrate the index used by testing the assumption of p= pi, or to incorporate the estimation of p into the study design.

  9. Performance simulation of an x-ray detector for spectral CT with combined Si and Cd[Zn]Te detection layers.

    PubMed

    Herrmann, Christoph; Engel, Klaus-Jürgen; Wiegert, Jens

    2010-12-21

    The most obvious problem in obtaining spectral information with energy-resolving photon counting detectors in clinical computed tomography (CT) is the huge x-ray flux present in conventional CT systems. At high tube voltages (e.g. 140 kVp), despite the beam shaper, this flux can be close to 10⁹ Mcps mm⁻² in the direct beam or in regions behind the object, which are close to the direct beam. Without accepting the drawbacks of truncated reconstruction, i.e. estimating missing direct-beam projection data, a photon-counting energy-resolving detector has to be able to deal with such high count rates. Sub-structuring pixels into sub-pixels is not enough to reduce the count rate per pixel to values that today's direct converting Cd[Zn]Te material can cope with (≤ 10 Mcps in an optimistic view). Below 300 µm pixel pitch, x-ray cross-talk (Compton scatter and K-escape) and the effect of charge diffusion between pixels are problematic. By organising the detector in several different layers, the count rate can be further reduced. However this alone does not limit the count rates to the required level, since the high stopping power of the material becomes a disadvantage in the layered approach: a simple absorption calculation for 300 µm pixel pitch shows that the required layer thickness of below 10 Mcps/pixel for the top layers in the direct beam is significantly below 100 µm. In a horizontal multi-layer detector, such thin layers are very difficult to manufacture due to the brittleness of Cd[Zn]Te. In a vertical configuration (also called edge-on illumination (Ludqvist et al 2001 IEEE Trans. Nucl. Sci. 48 1530-6, Roessl et al 2008 IEEE NSS-MIC-RTSD 2008, Conf. Rec. Talk NM2-3)), bonding of the readout electronics (with pixel pitches below 100 µm) is not straightforward although it has already been done successfully (Pellegrini et al 2004 IEEE NSS MIC 2004 pp 2104-9). Obviously, for the top detector layers, materials with lower stopping power would be advantageous. The possible choices are, however, quite limited, since only 'mature' materials, which operate at room temperature and can be manufactured reliably should reasonably be considered. Since GaAs is still known to cause reliability problems, the simplest choice is Si, however with the drawback of strong Compton scatter which can cause considerable inter-pixel cross-talk. To investigate the potential and the problems of Si in a multi-layer detector, in this paper the combination of top detector layers made of Si with lower layers made of Cd[Zn]Te is studied by using Monte Carlo simulated detector responses. It is found that the inter-pixel cross-talk due to Compton scatter is indeed very high; however, with an appropriate cross-talk correction scheme, which is also described, the negative effects of cross-talk are shown to be removed to a very large extent.

  10. What Counts as Effective Input for Word Learning?

    ERIC Educational Resources Information Center

    Shneidman, Laura A.; Arroyo, Michelle E.; Levine, Susan C.; Goldin-Meadow, Susan

    2013-01-01

    The talk children hear from their primary caregivers predicts the size of their vocabularies. But children who spend time with multiple individuals also hear talk that others direct to them, as well as talk not directed to them at all. We investigated the effect of linguistic input on vocabulary acquisition in children who routinely spent time…

  11. Poverty, hunger, education, and residential status impact survival in HIV.

    PubMed

    McMahon, James; Wanke, Christine; Terrin, Norma; Skinner, Sally; Knox, Tamsin

    2011-10-01

    Despite combination antiretroviral therapy (ART), HIV infected people have higher mortality than non-infected. Lower socioeconomic status (SES) predicts higher mortality in many chronic illnesses but data in people with HIV is limited. We evaluated 878 HIV infected individuals followed from 1995 to 2005. Cox proportional hazards for all-cause mortality were estimated for SES measures and other factors. Mixed effects analyses examined how SES impacts factors predicting death. The 200 who died were older, had lower CD4 counts, and higher viral loads (VL). Age, transmission category, education, albumin, CD4 counts, VL, hunger, and poverty predicted death in univariate analyses; age, CD4 counts, albumin, VL, and poverty in the multivariable model. Mixed models showed associations between (1) CD4 counts with education and hunger; (2) albumin with education, homelessness, and poverty; and (3) VL with education and hunger. SES contributes to mortality in HIV infected persons directly and indirectly, and should be a target of health policy in this population.

  12. Regulation of hematopoiesis in the suspended rat as a model for space flight

    NASA Technical Reports Server (NTRS)

    Dunn, C. D. R.; Johnson, P. C.

    1984-01-01

    A series of studies was completed in which a variety of routine hematological and other parameters were obtained from sequential sampling of control and suspended rats. These data showed that, during suspension, the rats failed to gain weight at the same rate as the controls, ate and drank significantly less, demonstrated a transient increase in peripheral hematocrit and RBC count, a transient decrease in MCH, suppressed reticulocyte counts and a progressive decrease in MCV but no change in RBC shape. Leukocyte counts were variably decreased but no significant changes in platelet numbers were noted. Post-suspension, evidence of anemia was present from a reduced RBC count, hemoglobin, hematocrit, and MCV. A leukocytosis was also noted. Efforts directed to the collection of data aimed at understanding changes in blood volume during suspension are also discussed. As part of these studies the following parameters were investigated; RBC survival, in vitro leukocyte reactivity to PHA, bone marrow and spleen cellularity and morphology, ferrokinetics, and the hematopoietic inductive microenvironment.

  13. A Flight Photon Counting Camera for the WFIRST Coronagraph

    NASA Astrophysics Data System (ADS)

    Morrissey, Patrick

    2018-01-01

    A photon counting camera based on the Teledyne-e2v CCD201-20 electron multiplying CCD (EMCCD) is being developed for the NASA WFIRST coronagraph, an exoplanet imaging technology development of the Jet Propulsion Laboratory (Pasadena, CA) that is scheduled to launch in 2026. The coronagraph is designed to directly image planets around nearby stars, and to characterize their spectra. The planets are exceedingly faint, providing signals similar to the detector dark current, and require the use of photon counting detectors. Red sensitivity (600-980nm) is preferred to capture spectral features of interest. Since radiation in space affects the ability of the EMCCD to transfer the required single electron signals, care has been taken to develop appropriate shielding that will protect the cameras during a five year mission. In this poster, consideration of the effects of space radiation on photon counting observations will be described with the mitigating features of the camera design. An overview of the current camera flight system electronics requirements and design will also be described.

  14. The use of noise equivalent count rate and the NEMA phantom for PET image quality evaluation.

    PubMed

    Yang, Xin; Peng, Hao

    2015-03-01

    PET image quality is directly associated with two important parameters among others: count-rate performance and image signal-to-noise ratio (SNR). The framework of noise equivalent count rate (NECR) was developed back in the 1990s and has been widely used since then to evaluate count-rate performance for PET systems. The concept of NECR is not entirely straightforward, however, and among the issues requiring clarification are its original definition, its relationship to image quality, and its consistency among different derivation methods. In particular, we try to answer whether a higher NECR measurement using a standard NEMA phantom actually corresponds to better imaging performance. The paper includes the following topics: 1) revisiting the original analytical model for NECR derivation; 2) validating three methods for NECR calculation based on the NEMA phantom/standard; and 3) studying the spatial dependence of NECR and quantitative relationship between NECR and image SNR. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Automated Analysis of Human Sperm Number and Concentration (Oligospermia) Using Otsu Threshold Method and Labelling

    NASA Astrophysics Data System (ADS)

    Susrama, I. G.; Purnama, K. E.; Purnomo, M. H.

    2016-01-01

    Oligospermia is a male fertility issue defined as a low sperm concentration in the ejaculate. Normally the sperm concentration is 20-120 million/ml, while Oligospermia patients has sperm concentration less than 20 million/ml. Sperm test done in the fertility laboratory to determine oligospermia by checking fresh sperm according to WHO standards in 2010 [9]. The sperm seen in a microscope using a Neubauer improved counting chamber and manually count the number of sperm. In order to be counted automatically, this research made an automation system to analyse and count the sperm concentration called Automated Analysis of Sperm Concentration Counters (A2SC2) using Otsu threshold segmentation process and morphology. Data sperm used is the fresh sperm directly in the analysis in the laboratory from 10 people. The test results using A2SC2 method obtained an accuracy of 91%. Thus in this study, A2SC2 can be used to calculate the amount and concentration of sperm automatically

  16. Test of a mosquito eggshell isolation method and subsampling procedure.

    PubMed

    Turner, P A; Streever, W J

    1997-03-01

    Production of Aedes vigilax, the common salt-marsh mosquito, can be assessed by determining eggshell densities found in soil. In this study, 14 field-collected eggshell samples were used to test a subsampling technique and compare eggshell counts obtained with a flotation method to those obtained by direct examination of sediment (DES). Relative precision of the subsampling technique was assessed by determining the minimum number of subsamples required to estimate the true mean and confidence interval of a sample at a predetermined confidence level. A regression line was fitted to cube-root transformed eggshell counts obtained from flotation and DES and found to be significant (P < 0.001, r2 = 0.97). The flotation method allowed processing of samples in about one-third of the time required by DES, but recovered an average of 44% of the eggshells present. Eggshells obtained with the flotation method can be used to predict those from DES using the following equation: DES count = [1.386 x (flotation count)0.33 - 0.01]3.

  17. Association of peripheral differential leukocyte counts with dyslipidemia risk in Chinese patients with hypertension: insight from the China Stroke Primary Prevention Trial.

    PubMed

    Liu, Yanhong; Kong, Xiangyi; Wang, Wen; Fan, Fangfang; Zhang, Yan; Zhao, Min; Wang, Yi; Wang, Yupeng; Wang, Yu; Qin, Xianhui; Tang, Genfu; Wang, Binyan; Xu, Xiping; Hou, Fan Fan; Gao, Wei; Sun, Ningling; Li, Jianping; Venners, Scott A; Jiang, Shanqun; Huo, Yong

    2017-01-01

    The aim of the present study was to examine the association between peripheral differential leukocyte counts and dyslipidemia in a Chinese hypertensive population. A total of 10,866 patients with hypertension were enrolled for a comprehensive assessment of cardiovascular risk factors using data from the China Stroke Primary Prevention Trial. Plasma lipid levels and total leukocyte, neutrophil, and lymphocyte counts were determined according to standard methods. Peripheral differential leukocyte counts were consistently and positively associated with serum total cholesterol (TC), LDL cholesterol (LDL-C), and TG levels (all P < 0.001 for trend), while inversely associated with HDL cholesterol levels (P < 0.05 for trend). In subsequent analyses where serum lipids were dichotomized (dyslipidemia/normolipidemia), we found that patients in the highest quartile of total leukocyte count (≥7.6 × 10 9 cells/l) had 1.64 times the risk of high TG [95% confidence interval (CI): 1.46, 1.85], 1.34 times the risk of high TC (95% CI: 1.20, 1.50), and 1.24 times the risk of high LDL-C (95% CI: 1.12, 1.39) compared with their counterparts in the lowest quartile of total leukocyte count. Similar patterns were also observed with neutrophils and lymphocytes. In summary, these findings indicate that elevated differential leukocyte counts are directly associated with serum lipid levels and increased odds of dyslipidemia. Copyright © 2017 by the American Society for Biochemistry and Molecular Biology, Inc.

  18. Integrating chronological uncertainties for annually laminated lake sediments using layer counting, independent chronologies and Bayesian age modelling (Lake Ohau, South Island, New Zealand)

    NASA Astrophysics Data System (ADS)

    Vandergoes, Marcus J.; Howarth, Jamie D.; Dunbar, Gavin B.; Turnbull, Jocelyn C.; Roop, Heidi A.; Levy, Richard H.; Li, Xun; Prior, Christine; Norris, Margaret; Keller, Liz D.; Baisden, W. Troy; Ditchburn, Robert; Fitzsimons, Sean J.; Bronk Ramsey, Christopher

    2018-05-01

    Annually resolved (varved) lake sequences are important palaeoenvironmental archives as they offer a direct incremental dating technique for high-frequency reconstruction of environmental and climate change. Despite the importance of these records, establishing a robust chronology and quantifying its precision and accuracy (estimations of error) remains an essential but challenging component of their development. We outline an approach for building reliable independent chronologies, testing the accuracy of layer counts and integrating all chronological uncertainties to provide quantitative age and error estimates for varved lake sequences. The approach incorporates (1) layer counts and estimates of counting precision; (2) radiometric and biostratigrapic dating techniques to derive independent chronology; and (3) the application of Bayesian age modelling to produce an integrated age model. This approach is applied to a case study of an annually resolved sediment record from Lake Ohau, New Zealand. The most robust age model provides an average error of 72 years across the whole depth range. This represents a fractional uncertainty of ∼5%, higher than the <3% quoted for most published varve records. However, the age model and reported uncertainty represent the best fit between layer counts and independent chronology and the uncertainties account for both layer counting precision and the chronological accuracy of the layer counts. This integrated approach provides a more representative estimate of age uncertainty and therefore represents a statistically more robust chronology.

  19. Cleanliness of disposable vs nondisposable electrocardiography lead wires in children.

    PubMed

    Addison, Nancy; Quatrara, Beth; Letzkus, Lisa; Strider, David; Rovnyak, Virginia; Syptak, Virginia; Fuzy, Lisa

    2014-09-01

    Mediastinitis costs hospitals thousands of dollars a year and increases the incidence of patient morbidity and mortality. No studies have been done to evaluate adenosine triphosphate (ATP) counts on disposable and nondisposable electrocardiography (ECG) lead wires in pediatric patients. To compare the cleanliness of disposable and nondisposable ECG lead wires in postoperative pediatric cardiac surgery patients by measuring the quantity of ATP (in relative luminescence units [RLUs]). ATP levels correlate with microbial cell counts and are used by institutions to assess hospital equipment and cleanliness. A prospective, randomized trial was initiated with approval from the institutional review board. Verbal consent was obtained from the parents/guardians for each patient. Trained nurses performed ATP swabs on the right and left upper ECG cables on postoperative days 1, 2, and 3. This study enrolled 51 patients. The disposable ECG lead wire ATP count on postoperative day 1 (median, 157 RLUs) was significantly lower (P < .001) than the count for nondisposable ATP lead wires (median, 610 RLUs). On postoperative day 2, the ATP count for the disposable ECG lead wires (median, 200 RLUs) was also lower (P = .06) than the count for the nondisposable ECG lead wires (median, 453 RLUs). Results of this study support the use of disposable ECG lead wires in postoperative pediatric cardiac surgery patients for at least the first 48 hours as a direct strategy to reduce the ATP counts on ECG lead wires. ©2014 American Association of Critical-Care Nurses.

  20. Comparison of visual-based helicopter and fixed-wing forward-looking infrared surveys for counting white-tailed deer Odocoileus virginianus

    USGS Publications Warehouse

    Storm, Daniel J.; Samuel, Michael D.; Van Deelen, Timothy R.; Malcolm, Karl D.; Rolley, Robert E.; Frost, Nancy A.; Bates, Donald P.; Richards, Bryan J.

    2011-01-01

    Aerial surveys using direct counts of animals are commonly used to estimate deer abundance. Forward-looking infrared (FLIR) technology is increasingly replacing traditional methods such as visual observation from helicopters. Our goals were to compare fixed-wing FLIR and visual, helicopter-based counts in terms of relative bias, influence of snow cover and cost. We surveyed five plots: four 41.4 km2 plots with free-ranging white-tailed deer Odocoileus virginianus populations in Wisconsin and a 5.3 km2 plot with a white-tailed deer population contained by a high fence in Michigan. We surveyed plots using both fixed-wing FLIR and helicopters, both with snow cover and without snow. None of the methods counted more deer than the other when snow was present. Helicopter counts were lower in the absence of snow, but lack of snow cover did not apparently affect FLIR. Group sizes of observed deer were similar regardless of survey method or season. We found that FLIR counts were generally precise (CV = 0.089) when two or three replicate surveys were conducted within a few hours. However, at the plot level, FLIR counts differed greatly between seasons, suggesting that detection rates vary over larger time scales. Fixed-wing FLIR was more costly than visual observers in helicopters and was more restrictive in terms of acceptable survey conditions. Further research is needed to understand what factors influence the detection of deer during FLIR surveys.

  1. Geometric Lagrangian approach to the physical degree of freedom count in field theory

    NASA Astrophysics Data System (ADS)

    Díaz, Bogar; Montesinos, Merced

    2018-05-01

    To circumvent some technical difficulties faced by the geometric Lagrangian approach to the physical degree of freedom count presented in the work of Díaz, Higuita, and Montesinos [J. Math. Phys. 55, 122901 (2014)] that prevent its direct implementation to field theory, in this paper, we slightly modify the geometric Lagrangian approach in such a way that its resulting version works perfectly for field theory (and for particle systems, of course). As in previous work, the current approach also allows us to directly get the Lagrangian constraints, a new Lagrangian formula for the counting of the number of physical degrees of freedom, the gauge transformations, and the number of first- and second-class constraints for any action principle based on a Lagrangian depending on the fields and their first derivatives without performing any Dirac's canonical analysis. An advantage of this approach over the previous work is that it also allows us to handle the reducibility of the constraints and to get the off-shell gauge transformations. The theoretical framework is illustrated in 3-dimensional generalized general relativity (Palatini and Witten's exotic actions), Chern-Simons theory, 4-dimensional BF theory, and 4-dimensional general relativity given by Palatini's action with a cosmological constant.

  2. Analysis of Texture Using the Fractal Model

    NASA Technical Reports Server (NTRS)

    Navas, William; Espinosa, Ramon Vasquez

    1997-01-01

    Properties such as the fractal dimension (FD) can be used for feature extraction and classification of regions within an image. The FD measures the degree of roughness of a surface, so this number is used to characterize a particular region, in order to differentiate it from another. There are two basic approaches discussed in the literature to measure FD: the blanket method, and the box counting method. Both attempt to measure FD by estimating the change in surface area with respect to the change in resolution. We tested both methods but box counting resulted computationally faster and gave better results. Differential Box Counting (DBC) was used to segment a collage containing three textures. The FD is independent of directionality and brightness so five features were used derived from the original image to account for directionality and gray level biases. FD can not be measured on a point, so we use a window that slides across the image giving values of FD to the pixel on the center of the window. Windowing blurs the boundaries of adjacent classes, so an edge-preserving, feature-smoothing algorithm is used to improve classification within segments and to make the boundaries sharper. Segmentation using DBC was 90.8910 accurate.

  3. Analysis of counting errors in the phase/Doppler particle analyzer

    NASA Technical Reports Server (NTRS)

    Oldenburg, John R.

    1987-01-01

    NASA is investigating the application of the Phase Doppler measurement technique to provide improved drop sizing and liquid water content measurements in icing research. The magnitude of counting errors were analyzed because these errors contribute to inaccurate liquid water content measurements. The Phase Doppler Particle Analyzer counting errors due to data transfer losses and coincidence losses were analyzed for data input rates from 10 samples/sec to 70,000 samples/sec. Coincidence losses were calculated by determining the Poisson probability of having more than one event occurring during the droplet signal time. The magnitude of the coincidence loss can be determined, and for less than a 15 percent loss, corrections can be made. The data transfer losses were estimated for representative data transfer rates. With direct memory access enabled, data transfer losses are less than 5 percent for input rates below 2000 samples/sec. With direct memory access disabled losses exceeded 20 percent at a rate of 50 samples/sec preventing accurate number density or mass flux measurements. The data transfer losses of a new signal processor were analyzed and found to be less than 1 percent for rates under 65,000 samples/sec.

  4. When every cent counts

    NASA Astrophysics Data System (ADS)

    Egan, Renate J.; Chang, Nathan L.

    2018-05-01

    Photovoltaic electricity is increasingly competitive with conventional electricity generation, and cost analyses are now being developed for early-stage technologies. A recent techno-economic analysis looks at thin-film tandem photovoltaics to inform research directions.

  5. Traffic monitoring guide

    DOT National Transportation Integrated Search

    1995-02-01

    This guide is designed to provide direction on the monitoring of traffic characteristics. It begins with a discussion of the structure of traffic characteristics monitoring and traffic counting. The next two sections cover vehicle classification and ...

  6. Marginalized zero-altered models for longitudinal count data.

    PubMed

    Tabb, Loni Philip; Tchetgen, Eric J Tchetgen; Wellenius, Greg A; Coull, Brent A

    2016-10-01

    Count data often exhibit more zeros than predicted by common count distributions like the Poisson or negative binomial. In recent years, there has been considerable interest in methods for analyzing zero-inflated count data in longitudinal or other correlated data settings. A common approach has been to extend zero-inflated Poisson models to include random effects that account for correlation among observations. However, these models have been shown to have a few drawbacks, including interpretability of regression coefficients and numerical instability of fitting algorithms even when the data arise from the assumed model. To address these issues, we propose a model that parameterizes the marginal associations between the count outcome and the covariates as easily interpretable log relative rates, while including random effects to account for correlation among observations. One of the main advantages of this marginal model is that it allows a basis upon which we can directly compare the performance of standard methods that ignore zero inflation with that of a method that explicitly takes zero inflation into account. We present simulations of these various model formulations in terms of bias and variance estimation. Finally, we apply the proposed approach to analyze toxicological data of the effect of emissions on cardiac arrhythmias.

  7. Marginalized zero-altered models for longitudinal count data

    PubMed Central

    Tabb, Loni Philip; Tchetgen, Eric J. Tchetgen; Wellenius, Greg A.; Coull, Brent A.

    2015-01-01

    Count data often exhibit more zeros than predicted by common count distributions like the Poisson or negative binomial. In recent years, there has been considerable interest in methods for analyzing zero-inflated count data in longitudinal or other correlated data settings. A common approach has been to extend zero-inflated Poisson models to include random effects that account for correlation among observations. However, these models have been shown to have a few drawbacks, including interpretability of regression coefficients and numerical instability of fitting algorithms even when the data arise from the assumed model. To address these issues, we propose a model that parameterizes the marginal associations between the count outcome and the covariates as easily interpretable log relative rates, while including random effects to account for correlation among observations. One of the main advantages of this marginal model is that it allows a basis upon which we can directly compare the performance of standard methods that ignore zero inflation with that of a method that explicitly takes zero inflation into account. We present simulations of these various model formulations in terms of bias and variance estimation. Finally, we apply the proposed approach to analyze toxicological data of the effect of emissions on cardiac arrhythmias. PMID:27867423

  8. Photon-counting image sensors for the ultraviolet

    NASA Technical Reports Server (NTRS)

    Jenkins, E. B.

    1985-01-01

    An investigation on specific performance details of photon counting, ultraviolet image sensors having 2-dimensional formats is reviewed. In one study, controlled experiments were performed which compare the quantum efficiencies, in pulse counting mode, of CsI photocathodes deposited on: (1) the front surface of a microchannel plate (MCP), (2) a solid surface in front of an MCP, and (3) an intensified CCD image sensor (ICCD) where a CCD is directly bombarded by accelerated photoelectrons. Tests indicated that the detection efficiency of the CsI-coated MCP at 1026 A is lower by a factor of 2.5 than that of the MCP with a separate, opaque CsI photocathode, and the detection efficiency ratio increases substantially at longer wavelengths (ratio is 5 at 1216 A and 20 at 1608 A).

  9. LACUS Forum XXV, [1998].

    ERIC Educational Resources Information Center

    Hwang, Shin Ja J., Ed.; Lommel, Arle R., Ed.

    Papers from the conference include: "English and Human Morphology: 'Naturalness' in Counting and Measuring" (Sullivan); "Phonetic and Phonemic Change Revisited" (Lockwood); "Virtual Reality" (Langacker); "Path Directions in ASL Agreement Verbs are Predictable on Semantic Grounds" (Taub); "Temporal…

  10. Proton-induced radioactivity in NaI (Tl) scintillation detectors

    NASA Technical Reports Server (NTRS)

    Fishman, G. J.

    1977-01-01

    Radioactivity induced by protons in sodium iodide scintillation crystals were calculated and directly measured. These data are useful in determining trapped radiation and cosmic-ray induced, background-counting rates in spaceborne detectors.

  11. Fission meter and neutron detection using poisson distribution comparison

    DOEpatents

    Rowland, Mark S; Snyderman, Neal J

    2014-11-18

    A neutron detector system and method for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. Comparison of the observed neutron count distribution with a Poisson distribution is performed to distinguish fissile material from non-fissile material.

  12. Microradiography with Semiconductor Pixel Detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jakubek, Jan; Cejnarova, Andrea; Dammer, Jiri

    High resolution radiography (with X-rays, neutrons, heavy charged particles, ...) often exploited also in tomographic mode to provide 3D images stands as a powerful imaging technique for instant and nondestructive visualization of fine internal structure of objects. Novel types of semiconductor single particle counting pixel detectors offer many advantages for radiation imaging: high detection efficiency, energy discrimination or direct energy measurement, noiseless digital integration (counting), high frame rate and virtually unlimited dynamic range. This article shows the application and potential of pixel detectors (such as Medipix2 or TimePix) in different fields of radiation imaging.

  13. On the decades-long stability of the interstellar wind through the solar system

    NASA Astrophysics Data System (ADS)

    Lallement, R.; Bertaux, J. L.

    2014-05-01

    We have revisited the series of observations recently used to infer a temporal variation in the interstellar helium flow over the past forty years. Concerning the recent IBEX-Lo direct detection of helium neutrals, there are two types of precise and unambiguous measurements that do not rely on the exact response of the instrument: the count rate maxima as a function of the spin angle, which determines the ecliptic latitude of the flow, and the count rate maxima as a function of IBEX longitude, which determines a tight relationship between the ecliptic longitude of the flow and its velocity far from the Sun. These measurements provide parameters (and couples of parameters in the second case) that are remarkably similar to the canonical, old values. In contrast, the preferred choice of a lower velocity and higher longitude reported before from IBEX data is only based on the count rate variation (at each spin phase maximum) as a function of the satellite longitude, when drifting across the region of high fluxes. We have examined the consequences of dead-time counting effects and conclude that including them at a realistic level is sufficient to reconcile the data with the old parameters, calling for further investigations. We discuss the analyses of the STEREO pickup ion data and argue that the statistical method that has been preferred to infer the neutral flow longitude (instead of the more direct method based on the pickup ion maximum flux directions) is not appropriate. Moreover, transport effects may have been significant at the very weak solar activity level of 2007-2009, in which case the longitudes of the pickup ion maxima are only upper limits on the flow longitude. Finally, we found that using some flow longitude determinations based on UV glow data is not adequate. Based on this global study, and at variance with recent conclusions, we find no evidence for a temporal variability of the interstellar helium flow. This has implications for inner and outer heliosphere studies.

  14. Multisite study of particle number concentrations in urban air.

    PubMed

    Harrison, Roy M; Jones, Alan M

    2005-08-15

    Particle number concentration data are reported from a total of eight urban site locations in the United Kingdom. Of these, six are central urban background sites, while one is an urban street canyon (Marylebone Road) and another is influenced by both a motorway and a steelworks (Port Talbot). The concentrations are generally of a similar order to those reported in the literature, although higher than those in some of the other studies. Highest concentrations are at the Marylebone Road site and lowest are at the Port Talbot site. The central urban background locations lie somewhere between with concentrations typically around 20 000 cm(-3). A seasonal pattern affects all sites, with highest concentrations in the winter months and lowest concentrations in the summer. Data from all sites show a diurnal variation with a morning rush hour peak typical of an anthropogenic pollutant. When the dilution effects of windspeed are accounted for, the data show little directionality at the central urban background sites indicating the influence of sources from all directions as might be expected if the major source were road traffic. At the London Marylebone Road site there is high directionality driven by the air circulation in the street canyon, and at the Port Talbot site different diurnal patterns are seen for particle number count and PM10 influenced by emissions from road traffic (particle number count) and the steelworks (PM10) and local meteorological factors. Hourly particle number concentrations are generally only weakly correlated to NO(x) and PM10, with the former showing a slightly closer relationship. Correlations between daily average particle number count and PM10 were also weak. Episodes of high PM10 concentration in summer typically show low particle number concentrations consistent with transport of accumulation mode secondary aerosol, while winter episodes are frequently associated with high PM10 and particle number count arising from poor dispersion of local primary emissions.

  15. Comparison of GT3X accelerometer and YAMAX pedometer steps/day in a free-living sample of overweight and obese adults.

    PubMed

    Barriera, Tiago V; Tudor-Locke, Catrine; Champagne, Catherine M; Broyles, Stephanie T; Johnson, William D; Katzmarzyk, Peter T

    2013-02-01

    The purpose of this study was to compare steps/day detected by the YAMAX SW-200 pedometer versus the Actigraph GT3X accelerometer in free-living adults. Daily YAMAX and GT3X steps were collected from a sample of 23 overweight and obese participants (78% female; age = 52.6 ± 8.4 yr.; BMI = 31.0 ± 3.7 m·kg-2). Because a pedometer is more likely to be used in a community-based intervention program, it was used as the standard for comparison. Percent difference (PD) and absolute percent difference (APD) were calculated to examine between-instrument agreement. In addition, days were categorized based on PD: a) under-counting (> -10 PD), b) acceptable counting (-10 to 10 PD), and c) over-counting (> 10 PD). The YAMAX and GT3X detected 8,025 ± 3,967 and 7131 ± 3066 steps/day, respectively, and the outputs were highly correlated (r = .87). Average PD was -3.1% ± 30.7% and average APD was 23.9% ± 19.4%. Relative to the YAMAX, 53% of the days detected by the GT3X were classified as under-counting, 25% acceptable counting, and 23% over-counting. Although the output of these 2 instruments is highly correlated, caution is advised when directly comparing or using their output interchangeably.

  16. Possible association of Bifidobacterium and Lactobacillus in the gut microbiota of patients with major depressive disorder.

    PubMed

    Aizawa, Emiko; Tsuji, Hirokazu; Asahara, Takashi; Takahashi, Takuya; Teraishi, Toshiya; Yoshida, Sumiko; Ota, Miho; Koga, Norie; Hattori, Kotaro; Kunugi, Hiroshi

    2016-09-15

    Bifidobacterium and Lactobacillus in the gut have been suggested to have a beneficial effect on stress response and depressive disorder. We examined whether these bacterial counts are reduced in patients with major depressive disorder (MDD) than in healthy controls. Bifidobacterium and Lactobacillus counts in fecal samples were estimated in 43 patients and 57 controls using bacterial rRNA-targeted reverse transcription-quantitative polymerase chain reaction The patients had significantly lower Bifidobacterium counts (P=0.012) and tended to have lower Lactobacillus counts (P=0.067) than the controls. Individuals whose bacterial counts below the optimal cut-off point (9.53 and 6.49log10 cells/g for Bifidobacterium and Lactobacillus, respectively) were significantly more common in the patients than in the controls for both bacteria (Bifidobacterium: odds ratio 3.23, 95% confidence interval [CI] 1.38-7.54, P=0.010; Lactobacillus: 2.57, 95% CI 1.14-5.78, P=0.027). Using the same cut-off points, we observed an association between the bacterial counts and Irritable bowel syndrome. Frequency of fermented milk consumption was associated with higher Bifidobacterium counts in the patients. The findings should be interpreted with caution since effects of gender and diet were not fully taken into account in the analysis. Our results provide direct evidence, for the first time, that individuals with lower Bifidobacterium and/or Lactobacillus counts are more common in patients with MDD compared to controls. Our findings provide new insight into the pathophysiology of MDD and will enhance future research on the use of pro- and prebiotics in the treatment of MDD. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. Called to Account: New Directions in School Accountability. Quality Counts. Education Week. Volume 35, Number 16

    ERIC Educational Resources Information Center

    Edwards, Virginia B., Ed.

    2016-01-01

    For the past decade and a half, the fight to improve America's schools has been fought largely on two fronts: academic standards as one battleground, and accountability the other, with the issue of mandatory testing adding heat to a very public--and increasingly politicized--debate. The questions for policymakers and educators are as direct as…

  18. Parametric Amplification For Detecting Weak Optical Signals

    NASA Technical Reports Server (NTRS)

    Hemmati, Hamid; Chen, Chien; Chakravarthi, Prakash

    1996-01-01

    Optical-communication receivers of proposed type implement high-sensitivity scheme of optical parametric amplification followed by direct detection for reception of extremely weak signals. Incorporates both optical parametric amplification and direct detection into optimized design enhancing effective signal-to-noise ratios during reception in photon-starved (photon-counting) regime. Eliminates need for complexity of heterodyne detection scheme and partly overcomes limitations imposed on older direct-detection schemes by noise generated in receivers and by limits on quantum efficiencies of photodetectors.

  19. The NuSTAR Extragalactic Surveys: The Number Counts Of Active Galactic Nuclei And The Resolved Fraction Of The Cosmic X-ray Background

    NASA Technical Reports Server (NTRS)

    Harrison, F. A.; Aird, J.; Civano, F.; Lansbury, G.; Mullaney, J. R.; Ballentyne, D. R.; Alexander, D. M.; Stern, D.; Ajello, M.; Barret, D.; hide

    2016-01-01

    We present the 3-8 kiloelectronvolts and 8-24 kiloelectronvolts number counts of active galactic nuclei (AGNs) identified in the Nuclear Spectroscopic Telescope Array (NuSTAR) extragalactic surveys. NuSTAR has now resolved 33 percent -39 percent of the X-ray background in the 8-24 kiloelectronvolts band, directly identifying AGNs with obscuring columns up to approximately 10 (exp 25) per square centimeter. In the softer 3-8 kiloelectronvolts band the number counts are in general agreement with those measured by XMM-Newton and Chandra over the flux range 5 times 10 (exp -15) less than or approximately equal to S (3-8 kiloelectronvolts) divided by ergs per second per square centimeter less than or approximately equal to 10 (exp -12) probed by NuSTAR. In the hard 8-24 kiloelectronvolts band NuSTAR probes fluxes over the range 2 times 10 (exp -14) less than or approximately equal to S (8-24 kiloelectronvolts) divided by ergs per second per square centimeter less than or approximately equal to 10 (exp -12), a factor approximately 100 times fainter than previous measurements. The 8-24 kiloelectronvolts number counts match predictions from AGN population synthesis models, directly confirming the existence of a population of obscured and/or hard X-ray sources inferred from the shape of the integrated cosmic X-ray background. The measured NuSTAR counts lie significantly above simple extrapolation with a Euclidian slope to low flux of the Swift/BAT15-55 kiloelectronvolts number counts measured at higher fluxes (S (15-55 kiloelectronvolts) less than or approximately equal to 10 (exp -11) ergs per second per square centimeter), reflecting the evolution of the AGN population between the Swift/BAT local (redshift is less than 0.1) sample and NuSTAR's redshift approximately equal to 1 sample. CXB (Cosmic X-ray Background) synthesis models, which account for AGN evolution, lie above the Swift/BAT measurements, suggesting that they do not fully capture the evolution of obscured AGNs at low redshifts

  20. Potassium Counts.

    ERIC Educational Resources Information Center

    Gipps, John

    1995-01-01

    Presents an activity to determine whether the radioactivity of a pure potassium salt is directly proportional to the amount of potassium in it and whether this could be used as a method of analysis for potassium in a solid. (MKR)

  1. Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications

    PubMed Central

    Shrestha, Suman; Karellas, Andrew; Shi, Linxi; Gounis, Matthew J.; Bellazzini, Ronaldo; Spandre, Gloria; Brez, Alessandro; Minuti, Massimo

    2016-01-01

    Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications. PMID:27147324

  2. Photon-counting hexagonal pixel array CdTe detector: Spatial resolution characteristics for image-guided interventional applications.

    PubMed

    Vedantham, Srinivasan; Shrestha, Suman; Karellas, Andrew; Shi, Linxi; Gounis, Matthew J; Bellazzini, Ronaldo; Spandre, Gloria; Brez, Alessandro; Minuti, Massimo

    2016-05-01

    High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.

  3. Interplanetary Scintillation studies with the Murchison Wide-field Array III: Comparison of source counts and densities for radio sources and their sub-arcsecond components at 162 MHz

    NASA Astrophysics Data System (ADS)

    Chhetri, R.; Ekers, R. D.; Morgan, J.; Macquart, J.-P.; Franzen, T. M. O.

    2018-06-01

    We use Murchison Widefield Array observations of interplanetary scintillation (IPS) to determine the source counts of point (<0.3 arcsecond extent) sources and of all sources with some subarcsecond structure, at 162 MHz. We have developed the methodology to derive these counts directly from the IPS observables, while taking into account changes in sensitivity across the survey area. The counts of sources with compact structure follow the behaviour of the dominant source population above ˜3 Jy but below this they show Euclidean behaviour. We compare our counts to those predicted by simulations and find a good agreement for our counts of sources with compact structure, but significant disagreement for point source counts. Using low radio frequency SEDs from the GLEAM survey, we classify point sources as Compact Steep-Spectrum (CSS), flat spectrum, or peaked. If we consider the CSS sources to be the more evolved counterparts of the peaked sources, the two categories combined comprise approximately 80% of the point source population. We calculate densities of potential calibrators brighter than 0.4 Jy at low frequencies and find 0.2 sources per square degrees for point sources, rising to 0.7 sources per square degree if sources with more complex arcsecond structure are included. We extrapolate to estimate 4.6 sources per square degrees at 0.04 Jy. We find that a peaked spectrum is an excellent predictor for compactness at low frequencies, increasing the number of good calibrators by a factor of three compared to the usual flat spectrum criterion.

  4. A structural equation model of patient-healthcare provider relationships and HIV-infected patient outcomes in Chinese populations.

    PubMed

    Chen, Wei-Ti; Shiu, Chengshi; Yang, Joyce P; Chuang, Peing; Zhang, Lin; Bao, Meijuan; Lu, Hongzhou

    2018-03-01

    Obtaining maximum antiretroviral therapy (ART) adherence is critical for maintaining a high CD4 count and strong immune function in PLWHA. Key factors for achieving optimum adherence include good medication self-efficacy, decreased medication-taking difficulties, and positive patient-healthcare provider (HCP) relationships. Limited studies have analyzed the correlation of these factors and ART adherence in Chinese population. In this paper, structural equation modeling was performed to assess the proposed model of relations between patient-HCP relationships and adherence. Audio Computer-Assisted Self-Interview (ACASI) software was used to collect data on ART adherence and patient variables among 227 PLWHA in Shanghai and Taipei. Participants completed a one-time 60-minute ACASI survey that consisted of standardized measures to assess demographics, recent CD4 counts, self-efficacy, patient-HCP relationship, adherence, and medication-taking difficulties. The data shown the relationship between patient-HCP relationships and adherence was significantly consistent with mediation by medication self-efficacy. However, patient-HCP interaction did not directly influence medication-taking difficulties, and medication-taking difficulties did not significantly affect CD4 counts. Furthermore, patient-HCP interactions did not directly impact CD4 counts; rather, the relation was consistent with mediation (by either better medication self-efficacy or better adherence) or by improved adherence alone. Future interventions should be designed to enhance self-management and provide better patient-HCP communication. This improved communication will enhance medication self-efficacy and decrease medication-taking difficulties. This in turn will improve medication adherence and immune function among PLWHA.

  5. Is Neural Activity Detected by ERP-Based Brain-Computer Interfaces Task Specific?

    PubMed

    Wenzel, Markus A; Almeida, Inês; Blankertz, Benjamin

    2016-01-01

    Brain-computer interfaces (BCIs) that are based on event-related potentials (ERPs) can estimate to which stimulus a user pays particular attention. In typical BCIs, the user silently counts the selected stimulus (which is repeatedly presented among other stimuli) in order to focus the attention. The stimulus of interest is then inferred from the electroencephalogram (EEG). Detecting attention allocation implicitly could be also beneficial for human-computer interaction (HCI), because it would allow software to adapt to the user's interest. However, a counting task would be inappropriate for the envisaged implicit application in HCI. Therefore, the question was addressed if the detectable neural activity is specific for silent counting, or if it can be evoked also by other tasks that direct the attention to certain stimuli. Thirteen people performed a silent counting, an arithmetic and a memory task. The tasks required the subjects to pay particular attention to target stimuli of a random color. The stimulus presentation was the same in all three tasks, which allowed a direct comparison of the experimental conditions. Classifiers that were trained to detect the targets in one task, according to patterns present in the EEG signal, could detect targets in all other tasks (irrespective of some task-related differences in the EEG). The neural activity detected by the classifiers is not strictly task specific but can be generalized over tasks and is presumably a result of the attention allocation or of the augmented workload. The results may hold promise for the transfer of classification algorithms from BCI research to implicit relevance detection in HCI.

  6. A novel rotometer based on a RISC microcontroller.

    PubMed

    Heredia-López, F J; Bata-García, J L; Alvarez-Cervera, F J; Góngora-Alfaro, J L

    2002-08-01

    A new, low-cost rotometer, based on a reduced instruction set computer (RISC) microcontroller, is presented. Like earlier devices, it counts the number and direction of full turns for predetermined time periods during the evaluation of turning behavior induced by drug administration in rats. The present stand-alone system includes a nonvolatile memory for long-term data storage and a serial port for data transmission. It also contains a display for monitoring the experiments and has battery backup to avoid interruptions owing to power failures. A high correlation was found (r > .988, p < 2 x 10(-14)) between the counts of the rotometer and those of two trained observers. The system reflects quantitative differences in turning behavior owing to pharmacological manipulations. It provides the most common counting parameters and is inexpensive, flexible, highly reliable, and completely portable (weight including batteries, 159 g).

  7. Wedge sampling for computing clustering coefficients and triangle counts on large graphs

    DOE PAGES

    Seshadhri, C.; Pinar, Ali; Kolda, Tamara G.

    2014-05-08

    Graphs are used to model interactions in a variety of contexts, and there is a growing need to quickly assess the structure of such graphs. Some of the most useful graph metrics are based on triangles, such as those measuring social cohesion. Despite the importance of these triadic measures, algorithms to compute them can be extremely expensive. We discuss the method of wedge sampling. This versatile technique allows for the fast and accurate approximation of various types of clustering coefficients and triangle counts. Furthermore, these techniques are extensible to counting directed triangles in digraphs. Our methods come with provable andmore » practical time-approximation tradeoffs for all computations. We provide extensive results that show our methods are orders of magnitude faster than the state of the art, while providing nearly the accuracy of full enumeration.« less

  8. Population estimates and monitoring guidelines for endangered Laysan Teal, Anas Laysanensis, at Midway Atoll: Pilot study results 2008-2010.

    USGS Publications Warehouse

    Reynolds, Michelle H.; Brinck, Kevin W.; Laniawe, Leona

    2011-01-01

    To improve the Laysan Teal population estimates, we recommend changes to the monitoring protocol. Additional years of data are needed to quantify inter-annual seasonal detection probabilities, which may allow the use of standardized direct counts as an unbiased index of population size. Survey protocols should be enhanced through frequent resights, regular survey intervals, and determining reliable standards to detect catastrophic declines and annual changes in adult abundance. In late 2009 to early 2010, 68% of the population was marked with unique color band combinations. This allowed for potentially accurate adult population estimates and survival estimates without the need to mark new birds in 2010, 2011, and possibly 2012. However, efforts should be made to replace worn or illegible bands so birds can be identified in future surveys. It would be valuable to develop more sophisticated population size and survival models using Program MARK, a state-of-the-art software package which uses likelihood models to analyze mark-recapture data. This would allow for more reliable adult population and survival estimates to compare with the ―source‖ Laysan Teal population on Laysan Island. These models will require additional years of resight data (> 1 year) and, in some cases, an intensive annual effort of marking and recapture. Because data indicate standardized all-wetland counts are a poor index of abundance, monitoring efforts could be improved by expanding resight surveys to include all wetlands, discontinuing the all-wetland counts, and reallocating some of the wetland count effort to collect additional opportunistic resights. Approximately two years of additional bimonthly surveys are needed to validate the direct count as an appropriate index of population abundance. Additional years of individual resight data will allow estimates of adult population size, as specified in recovery criteria, and to track species population dynamics at Midway Atoll.

  9. Effect of land uses and wind direction on the contribution of local sources to airborne pollen.

    PubMed

    Rojo, Jesús; Rapp, Ana; Lara, Beatriz; Fernández-González, Federico; Pérez-Badia, Rosa

    2015-12-15

    The interpretation of airborne pollen levels in cities based on the contribution of the surrounding flora and vegetation is a useful tool to estimate airborne allergen concentrations and, consequently, to determine the allergy risk for local residents. This study examined the pollen spectrum in a city in central Spain (Guadalajara) and analysed the vegetation landscape and land uses within a radius of 20km in an attempt to identify and locate the origin of airborne pollen and to determine the effect of meteorological variables on pollen emission and dispersal. The results showed that local wind direction was largely responsible for changes in the concentrations of different airborne pollen types. The land uses contributing most to airborne pollen counts were urban green spaces, though only 0.1% of the total surface area studied, and broadleaved forest which covered 5% of the study area. These two types of land use together accounted for 70% of the airborne pollen. Crops, scrubland and pastureland, though covering 80% of the total surface area, contributed only 18.6% to the total pollen count, and this contribution mainly consisted of pollen from Olea and herbaceous plants, including Poaceae, Urticaceae and Chenopodiaceae-Amaranthaceae. Pollen from ornamental species were mainly associated with easterly (Platanus), southerly (Cupressaceae) and westerly (Cupressaceae and Platanus) winds from the areas where the city's largest parks and gardens are located. Quercus pollen was mostly transported by winds blowing in from holm-oak stands on the eastern edge of the city. The highest Populus pollen counts were associated with easterly and westerly winds blowing in from areas containing rivers and streams. The airborne pollen counts generally rose with increasing temperature, solar radiation and hours of sunlight, all of which favour pollen release. In contrast, pollen counts declined with increased relative humidity and rainfall, which hinder airborne pollen transport. Copyright © 2015 Elsevier B.V. All rights reserved.

  10. Which Benefits of Research Participation Count as ‘Direct’?

    PubMed Central

    Friedman, Alexander; Robbins, Emily; Wendler, David

    2010-01-01

    It is widely held that individuals who are unable to provide informed consent should be enrolled in clinical research only when the risks are low, or the research offers them the prospect of direct benefit. There is now a rich literature on when the risks of clinical research are low enough to enroll individuals who cannot consent. Much less attention has focused on which benefits of research participation count as ‘direct’, and the few existing accounts disagree over how this crucial concept should be defined. This disagreement raises concern over whether those who cannot consent, including children and adults with severe dementia, are being adequately protected. The present paper attempts to address this concern by considering first what additional protections are needed for these vulnerable individuals. This analysis suggests that the extant definitions of direct benefits either provide insufficient protection for research subjects or pose excessive obstacles to appropriate research. This analysis also points to a modified definition of direct benefits with the potential to avoid these two extremes, protecting individuals who cannot consent without blocking appropriate research. PMID:20497168

  11. Real-time multi-mode neutron multiplicity counter

    DOEpatents

    Rowland, Mark S; Alvarez, Raymond A

    2013-02-26

    Embodiments are directed to a digital data acquisition method that collects data regarding nuclear fission at high rates and performs real-time preprocessing of large volumes of data into directly useable forms for use in a system that performs non-destructive assaying of nuclear material and assemblies for mass and multiplication of special nuclear material (SNM). Pulses from a multi-detector array are fed in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel, to reduce the latency associated with current shift-register systems. The word is read at regular intervals, all bits simultaneously, with no manipulation. The word is passed to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup. The word is used simultaneously in several internal processing schemes that assemble the data in a number of more directly useable forms. The detector includes a multi-mode counter that executes a number of different count algorithms in parallel to determine different attributes of the count data.

  12. Direct fissile assay of enriched uranium using random self-interrogation and neutron coincidence response

    DOEpatents

    Menlove, Howard O.; Stewart, James E.

    1986-01-01

    Apparatus and method for the direct, nondestructive evaluation of the .sup.235 U nuclide content of samples containing UF.sub.6, UF.sub.4, or UO.sub.2 utilizing the passive neutron self-interrogation of the sample resulting from the intrinsic production of neutrons therein. The ratio of the emitted neutron coincidence count rate to the total emitted neutron count rate is determined and yields a measure of the bulk fissile mass. The accuracy of the method is 6.8% (1.sigma.) for cylinders containing UF.sub.6 with enrichments ranging from 6% to 98% with measurement times varying from 3-6 min. The samples contained from below 1 kg to greater than 16 kg. Since the subject invention relies on fast neutron self-interrogation, complete sampling of the UF.sub.6 takes place, reducing difficulties arising from inhomogeneity of the sample which adversely affects other assay procedures.

  13. Direct fissile assay of enriched uranium using random self-interrogation and neutron coincidence response

    DOEpatents

    Menlove, H.O.; Stewart, J.E.

    1985-02-04

    Apparatus and method for the direct, nondestructive evaluation of the /sup 235/U nuclide content of samples containing UF/sub 6/, UF/sub 4/, or UO/sub 2/ utilizing the passive neutron self-interrogation of the sample resulting from the intrinsic production of neutrons therein. The ratio of the emitted neutron coincidence count rate to the total emitted neutron count rate is determined and yields a measure of the bulk fissile mass. The accuracy of the method is 6.8% (1sigma) for cylinders containing UF/sub 6/ with enrichments ranging from 6% to 98% with measurement times varying from 3-6 min. The samples contained from below 1 kg to greater than 16 kg. Since the subject invention relies on fast neutron self-interrogation, complete sampling of the UF/sub 6/ takes place, reducing difficulties arising from inhomogeneity of the sample which adversely affects other assay procedures. 4 figs., 1 tab.

  14. Emotion Unchained: Facial Expression Modulates Gaze Cueing under Cognitive Load.

    PubMed

    Pecchinenda, Anna; Petrucci, Manuel

    2016-01-01

    Direction of eye gaze cues spatial attention, and typically this cueing effect is not modulated by the expression of a face unless top-down processes are explicitly or implicitly involved. To investigate the role of cognitive control on gaze cueing by emotional faces, participants performed a gaze cueing task with happy, angry, or neutral faces under high (i.e., counting backward by 7) or low cognitive load (i.e., counting forward by 2). Results show that high cognitive load enhances gaze cueing effects for angry facial expressions. In addition, cognitive load reduces gaze cueing for neutral faces, whereas happy facial expressions and gaze affected object preferences regardless of load. This evidence clearly indicates a differential role of cognitive control in processing gaze direction and facial expression, suggesting that under typical conditions, when we shift attention based on social cues from another person, cognitive control processes are used to reduce interference from emotional information.

  15. Emotion Unchained: Facial Expression Modulates Gaze Cueing under Cognitive Load

    PubMed Central

    Petrucci, Manuel

    2016-01-01

    Direction of eye gaze cues spatial attention, and typically this cueing effect is not modulated by the expression of a face unless top-down processes are explicitly or implicitly involved. To investigate the role of cognitive control on gaze cueing by emotional faces, participants performed a gaze cueing task with happy, angry, or neutral faces under high (i.e., counting backward by 7) or low cognitive load (i.e., counting forward by 2). Results show that high cognitive load enhances gaze cueing effects for angry facial expressions. In addition, cognitive load reduces gaze cueing for neutral faces, whereas happy facial expressions and gaze affected object preferences regardless of load. This evidence clearly indicates a differential role of cognitive control in processing gaze direction and facial expression, suggesting that under typical conditions, when we shift attention based on social cues from another person, cognitive control processes are used to reduce interference from emotional information. PMID:27959925

  16. Spectral Detection of Soybean Aphid (Hemiptera: Aphididae) and Confounding Insecticide Effects in Soybean

    NASA Astrophysics Data System (ADS)

    Alves, Tavvs Micael

    Soybean aphid, Aphis glycines (Hemiptera: Aphididae) is the primary insect pest of soybean in the northcentral United States. Soybean aphid may cause stunted plants, leaf discoloration, plant death, and decrease soybean yield by 40%. Sampling plans have been developed for supporting soybean aphid management. However, growers' perception about time involved in direct insect counts has been contributing to a lower adoption of traditional pest scouting methods and may be associated with the use of prophylactic insecticide applications in soybean. Remote sensing of plant spectral (light-derived) responses to soybean aphid feeding is a promising alternative to estimate injury without direct insect counts and, thus, increase adoption and efficiency of scouting programs. This research explored the use of remote sensing of soybean reflectance for detection of soybean aphids and showed that foliar insecticides may have implications for subsequent use of soybean spectral reflectance for pest detection. (Abstract shortened by ProQuest.).

  17. High-Throughput Quantification of Bacterial-Cell Interactions Using Virtual Colony Counts

    PubMed Central

    Hoffmann, Stefanie; Walter, Steffi; Blume, Anne-Kathrin; Fuchs, Stephan; Schmidt, Christiane; Scholz, Annemarie; Gerlach, Roman G.

    2018-01-01

    The quantification of bacteria in cell culture infection models is of paramount importance for the characterization of host-pathogen interactions and pathogenicity factors involved. The standard to enumerate bacteria in these assays is plating of a dilution series on solid agar and counting of the resulting colony forming units (CFU). In contrast, the virtual colony count (VCC) method is a high-throughput compatible alternative with minimized manual input. Based on the recording of quantitative growth kinetics, VCC relates the time to reach a given absorbance threshold to the initial cell count using a series of calibration curves. Here, we adapted the VCC method using the model organism Salmonella enterica sv. Typhimurium (S. Typhimurium) in combination with established cell culture-based infection models. For HeLa infections, a direct side-by-side comparison showed a good correlation of VCC with CFU counting after plating. For MDCK cells and RAW macrophages we found that VCC reproduced the expected phenotypes of different S. Typhimurium mutants. Furthermore, we demonstrated the use of VCC to test the inhibition of Salmonella invasion by the probiotic E. coli strain Nissle 1917. Taken together, VCC provides a flexible, label-free, automation-compatible methodology to quantify bacteria in in vitro infection assays. PMID:29497603

  18. Intestinal parasitic infections in relation to HIV/AIDS status, diarrhea and CD4 T-cell count.

    PubMed

    Assefa, Shimelis; Erko, Berhanu; Medhin, Girmay; Assefa, Zelalem; Shimelis, Techalew

    2009-09-18

    HIV infection has been modifying both the epidemiology and outcome of parasitic infections. Hence, this study was undertaken to determine the prevalence of intestinal parasitic infection among people with and without HIV infection and its association with diarrhea and CD4 T-cell count. A cross-sectional study was conducted at Hawassa Teaching and Referral Hospital focusing on HIV positive individuals, who gave blood for CD4 T-cell count at their first enrollment and clients tested HIV negative from November, 2008 to March, 2009. Data on socio-demographic factors and diarrhea status were obtained by interviewing 378 consecutive participants (214 HIV positive and 164 HIV negative). Stool samples were collected from all study subjects and examined for parasites using direct, formol-ether and modified acid fast stain techniques. The prevalence of any intestinal parasitic infection was significantly higher among HIV positive participants. Specifically, rate of infection with Cryptosporidium, I. belli, and S. stercoralis were higher, particularly in those with CD4 count less than 200 cells/microL. Diarrhea was more frequent also at the same lower CD4 T-cell counts. Immunodeficiency increased the risk of having opportunistic parasites and diarrhea. Therefore; raising patient immune status and screening at least for those treatable parasites is important.

  19. Are mutagenic non D-loop direct repeat motifs in mitochondrial DNA under a negative selection pressure?

    PubMed Central

    Lakshmanan, Lakshmi Narayanan; Gruber, Jan; Halliwell, Barry; Gunawan, Rudiyanto

    2015-01-01

    Non D-loop direct repeats (DRs) in mitochondrial DNA (mtDNA) have been commonly implicated in the mutagenesis of mtDNA deletions associated with neuromuscular disease and ageing. Further, these DRs have been hypothesized to put a constraint on the lifespan of mammals and are under a negative selection pressure. Using a compendium of 294 mammalian mtDNA, we re-examined the relationship between species lifespan and the mutagenicity of such DRs. Contradicting the prevailing hypotheses, we found no significant evidence that long-lived mammals possess fewer mutagenic DRs than short-lived mammals. By comparing DR counts in human mtDNA with those in selectively randomized sequences, we also showed that the number of DRs in human mtDNA is primarily determined by global mtDNA properties, such as the bias in synonymous codon usage (SCU) and nucleotide composition. We found that SCU bias in mtDNA positively correlates with DR counts, where repeated usage of a subset of codons leads to more frequent DR occurrences. While bias in SCU and nucleotide composition has been attributed to nucleotide mutational bias, mammalian mtDNA still exhibit higher SCU bias and DR counts than expected from such mutational bias, suggesting a lack of negative selection against non D-loop DRs. PMID:25855815

  20. Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.

    Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less

  1. Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set

    DOE PAGES

    Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.; ...

    2018-03-03

    Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less

  2. Bayesian approach for counting experiment statistics applied to a neutrino point source analysis

    NASA Astrophysics Data System (ADS)

    Bose, D.; Brayeur, L.; Casier, M.; de Vries, K. D.; Golup, G.; van Eijndhoven, N.

    2013-12-01

    In this paper we present a model independent analysis method following Bayesian statistics to analyse data from a generic counting experiment and apply it to the search for neutrinos from point sources. We discuss a test statistic defined following a Bayesian framework that will be used in the search for a signal. In case no signal is found, we derive an upper limit without the introduction of approximations. The Bayesian approach allows us to obtain the full probability density function for both the background and the signal rate. As such, we have direct access to any signal upper limit. The upper limit derivation directly compares with a frequentist approach and is robust in the case of low-counting observations. Furthermore, it allows also to account for previous upper limits obtained by other analyses via the concept of prior information without the need of the ad hoc application of trial factors. To investigate the validity of the presented Bayesian approach, we have applied this method to the public IceCube 40-string configuration data for 10 nearby blazars and we have obtained a flux upper limit, which is in agreement with the upper limits determined via a frequentist approach. Furthermore, the upper limit obtained compares well with the previously published result of IceCube, using the same data set.

  3. Radioactive equilibrium in ancient marine sediments

    USGS Publications Warehouse

    Breger, I.A.

    1955-01-01

    Radioactive equilibrium in eight marine sedimentary formations has been studied by means of direct determinations of uranium, radium and thorium. Alpha-particle counting has also been carried out in order to cross-calibrate thick-source counting techniques. The maximum deviation from radioactive equilibrium that has been noted is 11 per cent-indicating that there is probably equilibrium in all the formations analyzed. Thick-source alpha-particle counting by means of a proportional counter or an ionization chamber leads to high results when the samples contain less than about 10 p.p.m. of uranium. For samples having a higher content of uranium the results are in excellent agreement with each other and with those obtained by direct analytical techniques. The thorium contents that have been obtained correspond well to the average values reported in the literature. The uranium content of marine sediments may be appreciably higher than the average values that have been reported for sedimentary rocks. Data show that there is up to fourteen times the percentage of uranium as of thorium in the formations studied and that the percentage of thorium never exceeds that of uranium. While the proximity of a depositional environment to a land mass may influence the concentration of uranium in a marine sediment, this is not true with thorium. ?? 1955.

  4. Marginalized zero-inflated negative binomial regression with application to dental caries

    PubMed Central

    Preisser, John S.; Das, Kalyan; Long, D. Leann; Divaris, Kimon

    2015-01-01

    The zero-inflated negative binomial regression model (ZINB) is often employed in diverse fields such as dentistry, health care utilization, highway safety, and medicine to examine relationships between exposures of interest and overdispersed count outcomes exhibiting many zeros. The regression coefficients of ZINB have latent class interpretations for a susceptible subpopulation at risk for the disease/condition under study with counts generated from a negative binomial distribution and for a non-susceptible subpopulation that provides only zero counts. The ZINB parameters, however, are not well-suited for estimating overall exposure effects, specifically, in quantifying the effect of an explanatory variable in the overall mixture population. In this paper, a marginalized zero-inflated negative binomial regression (MZINB) model for independent responses is proposed to model the population marginal mean count directly, providing straightforward inference for overall exposure effects based on maximum likelihood estimation. Through simulation studies, the finite sample performance of MZINB is compared to marginalized zero-inflated Poisson, Poisson, and negative binomial regression. The MZINB model is applied in the evaluation of a school-based fluoride mouthrinse program on dental caries in 677 children. PMID:26568034

  5. Acoustic Emission Parameters of Three Gorges Sandstone during Shear Failure

    NASA Astrophysics Data System (ADS)

    Xu, Jiang; Liu, Yixin; Peng, Shoujian

    2016-12-01

    In this paper, an experimental investigation of sandstone samples from the Three Gorges during shear failure was conducted using acoustic emission (AE) and direct shear tests. The AE count rate, cumulative AE count, AE energy, and amplitude of the sandstone samples were determined. Then, the relationships among the AE signals and shearing behaviors of the samples were analyzed in order to detect micro-crack initiation and propagation and reflect shear failure. The results indicated that both the shear strength and displacement exhibited a logarithmic relationship with the displacement rate at peak levels of stress. In addition, the various characteristics of the AE signals were apparent in various situations. The AE signals corresponded with the shear stress under different displacement rates. As the displacement rate increased, the amount of accumulative damage to each specimen decreased, while the AE energy peaked earlier and more significantly. The cumulative AE count primarily increased during the post-peak period. Furthermore, the AE count rate and amplitude exhibited two peaks during the peak shear stress period due to crack coalescence and rock bridge breakage. These isolated cracks later formed larger fractures and eventually caused ruptures.

  6. Direct quantification and distribution of tetracycline-resistant genes in meat samples by real-time polymerase chain reaction.

    PubMed

    Guarddon, Mónica; Miranda, Jose M; Vázquez, Beatriz I; Cepeda, Alberto; Franco, Carlos M

    2012-07-01

    The evolution of antimicrobial-resistant bacteria has become a threat to food safety and methods to control them are necessary. Counts of tetracycline-resistant (TR) bacteria by microbiological methods were compared with those obtained by quantitative PCR (qPCR) in 80 meat samples. TR Enterobacteriaceae counts were similar between the count plate method and qPCR (P= 0.24), whereas TR aerobic mesophilic bacteria counts were significantly higher by the microbiological method (P < 0.001). The distribution of tetA and tetB genes was investigated in different types of meat. tetA was detected in chicken meat (40%), turkey meat (100%), pork (20%), and beef (40%) samples, whereas tetB was detected in chicken meat (45%), turkey meat (70%), pork (30%), and beef (35%) samples. The presence of tetracycline residues was also investigated by a receptor assay. This study offers an alternative and rapid method for monitoring the presence of TR bacteria in meat and furthers the understanding of the distribution of tetA and tetB genes. © 2012 Institute of Food Technologists®

  7. Exploring the spatio-temporal relationship between two key aeroallergens and meteorological variables in the United Kingdom

    NASA Astrophysics Data System (ADS)

    Khwarahm, Nabaz; Dash, Jadunandan; Atkinson, Peter M.; Newnham, R. M.; Skjøth, C. A.; Adams-Groom, B.; Caulton, Eric; Head, K.

    2014-05-01

    Constructing accurate predictive models for grass and birch pollen in the air, the two most important aeroallergens, for areas with variable climate conditions such as the United Kingdom, require better understanding of the relationships between pollen count in the air and meteorological variables. Variations in daily birch and grass pollen counts and their relationship with daily meteorological variables were investigated for nine pollen monitoring sites for the period 2000-2010 in the United Kingdom. An active pollen count sampling method was employed at each of the monitoring stations to sample pollen from the atmosphere. The mechanism of this method is based on the volumetric spore traps of Hirst design (Hirst in Ann Appl Biol 39(2):257-265, 1952). The pollen season (start date, finish date) for grass and birch were determined using a first derivative method. Meteorological variables such as daily rainfall; maximum, minimum and average temperatures; cumulative sum of Sunshine duration; wind speed; and relative humidity were related to the grass and birch pollen counts for the pre-peak, post peak and the entire pollen season. The meteorological variables were correlated with the pollen count data for the following temporal supports: same-day, 1-day prior, 1-day mean prior, 3-day mean prior, 7-day mean prior. The direction of influence (positive/negative) of meteorological variables on pollen count varied for birch and grass, and also varied when the pollen season was treated as a whole season, or was segmented into the pre-peak and post-peak seasons. Maximum temperature, sunshine duration and rainfall were the most important variables influencing the count of grass pollen in the atmosphere. Both maximum temperature (pre-peak) and sunshine produced a strong positive correlation, and rain produced a strong negative correlation with grass pollen count in the air. Similarly, average temperature, wind speed and rainfall were the most important variables influencing the count of birch pollen in the air. Both wind speed and rain produced a negative correlation with birch pollen count in the air and average temperature produced a positive correlation.

  8. Fatigue in HIV illness: relationship to depression, physical limitations, and disability.

    PubMed

    Ferrando, S; Evans, S; Goggin, K; Sewell, M; Fishman, B; Rabkin, J

    1998-01-01

    This study was conducted to investigate the prevalence of clinical fatigue reported by gay/bisexual men at all HIV illness stages, and whether fatigue, while associated with depression, independently contributes to limitations in physical function and disability. HIV- men, HIV+ men with CD4 counts >500, HIV+ men with CD4 counts 200 to 500, and men with AIDS were compared on prevalence of clinical fatigue, as defined by a standardized instrument. Among HIV+ men, the relationships among fatigue, depressed mood, major depressive disorder, HIV illness markers (including CD4 count and HIV RNA viral load), physical limitations, and disability were assessed at baseline and after 1 year. The prevalence of clinical fatigue in men with CD4 counts <500 was 14%, significantly higher than HIV- men and HIV+ men with CD4 counts >500. However, fatigue was not directly correlated with CD4 count or HIV RNA. Fatigue was a chronic symptom that was associated with depressed mood, major depressive disorder, physical limitations, and disability. After 1 year, an increase in depressive symptoms predicted a small amount of variance in fatigue; however, depressive symptoms were not associated with physical limitations or disability after controlling for fatigue. Fatigue is a chronic symptom that is more prevalent in advanced HIV illness, and which, although associated with depression, does not seem to be merely a symptom of depression. Because fatigue contributes independently to physical limitations and disability, it should be assessed and treated.

  9. Look Again: A Response to "Another Look."

    ERIC Educational Resources Information Center

    Fraenkel, Jack R.

    1991-01-01

    Answers criticism directed at utilitarianism. Argues that the philosophy evaluates choices by identifying the factors that should be considered in weighing the morality of an act. Suggests that the distributive principle of impartiality means everyone's pleasure should count equally. (DK)

  10. 45 CFR 286.100 - What activities count towards the work participation rate?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... service programs; (8) Vocational educational training; (see § 286.105) (9) Job skills training directly... attendance at secondary school or in a course of study leading to a certificate of general equivalence, if a...

  11. Clustering in complex directed networks

    NASA Astrophysics Data System (ADS)

    Fagiolo, Giorgio

    2007-08-01

    Many empirical networks display an inherent tendency to cluster, i.e., to form circles of connected nodes. This feature is typically measured by the clustering coefficient (CC). The CC, originally introduced for binary, undirected graphs, has been recently generalized to weighted, undirected networks. Here we extend the CC to the case of (binary and weighted) directed networks and we compute its expected value for random graphs. We distinguish between CCs that count all directed triangles in the graph (independently of the direction of their edges) and CCs that only consider particular types of directed triangles (e.g., cycles). The main concepts are illustrated by employing empirical data on world-trade flows.

  12. Evaluating and improving count-based population inference: A case study from 31 years of monitoring Sandhill Cranes

    USGS Publications Warehouse

    Gerber, Brian D.; Kendall, William L.

    2017-01-01

    Monitoring animal populations can be difficult. Limited resources often force monitoring programs to rely on unadjusted or smoothed counts as an index of abundance. Smoothing counts is commonly done using a moving-average estimator to dampen sampling variation. These indices are commonly used to inform management decisions, although their reliability is often unknown. We outline a process to evaluate the biological plausibility of annual changes in population counts and indices from a typical monitoring scenario and compare results with a hierarchical Bayesian time series (HBTS) model. We evaluated spring and fall counts, fall indices, and model-based predictions for the Rocky Mountain population (RMP) of Sandhill Cranes (Antigone canadensis) by integrating juvenile recruitment, harvest, and survival into a stochastic stage-based population model. We used simulation to evaluate population indices from the HBTS model and the commonly used 3-yr moving average estimator. We found counts of the RMP to exhibit biologically unrealistic annual change, while the fall population index was largely biologically realistic. HBTS model predictions suggested that the RMP changed little over 31 yr of monitoring, but the pattern depended on assumptions about the observational process. The HBTS model fall population predictions were biologically plausible if observed crane harvest mortality was compensatory up to natural mortality, as empirical evidence suggests. Simulations indicated that the predicted mean of the HBTS model was generally a more reliable estimate of the true population than population indices derived using a moving 3-yr average estimator. Practitioners could gain considerable advantages from modeling population counts using a hierarchical Bayesian autoregressive approach. Advantages would include: (1) obtaining measures of uncertainty; (2) incorporating direct knowledge of the observational and population processes; (3) accommodating missing years of data; and (4) forecasting population size.

  13. The effects of hypobaric hypoxia (50.6 kPa) on blood components in guinea-pigs.

    PubMed

    Osada, H

    1991-06-01

    One hundred and five male (Hartley) guinea-pigs weighing 350-380 g and 30 splenectomized guinea-pigs were exposed to simulated hypobaric hypoxia of 50.6 kPa (equal to an altitude of 5486 m) for 14 days. The partial pressure of oxygen was set at half that at sea level. The white blood cell count increased significantly on day 3 of the simulated high altitude experiment but returned to normal on day 7, whereas the red blood cell count increased continuously. To study the effect of high altitude exposure on platelets, the platelet count in the splenectomized group was compared to that in a non-splenectomized group. Investigation of the resistance of red blood cell membranes to osmotic pressure under hypobaric conditions revealed a shift of the onset of haemolysis in the hyperosmotic direction. These findings may help to increase our understanding of the biochemical mechanisms of adaptation to hypobaric hypoxia.

  14. High-Precision Half-life Measurements for the Superallowed β+ Emitter 14O

    NASA Astrophysics Data System (ADS)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E. R.; Thomas, J. C.; Unsworth, C.

    2014-03-01

    The half-life of 14O, a superallowed Fermi β+ emitter, has been determined via simultaneous γ and β counting experiments at TRIUMF's Isotope Separator and Accelerator facility. Following the implantation of 14O samples at the center of the 8π spectrometer, a γ counting measurement was performed by detecting the 2313 keV γ-rays emitted from the first excited state of the daughter 14N using 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned directly behind the implantation site. The results, T½(γ) = 70:632 ± 0:094 s and T½(β) = 70:610 ± 0:030 s, are consistent with one another and, together with eight previous measurements, establish a new average for the 14O half-life of T½ = 70:619 ± 0:011 s with a reduced χ2 of 0.99.

  15. Seasonal and Long-Term Changes in Relative Abundance of Bull Sharks from a Tourist Shark Feeding Site in Fiji

    PubMed Central

    Brunnschweiler, Juerg M.; Baensch, Harald

    2011-01-01

    Shark tourism has become increasingly popular, but remains controversial because of major concerns originating from the need of tour operators to use bait or chum to reliably attract sharks. We used direct underwater sampling to document changes in bull shark Carcharhinus leucas relative abundance at the Shark Reef Marine Reserve, a shark feeding site in Fiji, and the reproductive cycle of the species in Fijian waters. Between 2003 and 2009, the total number of C. leucas counted on each day ranged from 0 to 40. Whereas the number of C. leucas counted at the feeding site increased over the years, shark numbers decreased over the course of a calendar year with fewest animals counted in November. Externally visible reproductive status information indicates that the species' seasonal departure from the feeding site may be related to reproductive activity. PMID:21346792

  16. Waveguide integrated superconducting single-photon detectors with high internal quantum efficiency at telecom wavelengths

    PubMed Central

    Kahl, Oliver; Ferrari, Simone; Kovalyuk, Vadim; Goltsman, Gregory N.; Korneev, Alexander; Pernice, Wolfram H. P.

    2015-01-01

    Superconducting nanowire single-photon detectors (SNSPDs) provide high efficiency for detecting individual photons while keeping dark counts and timing jitter minimal. Besides superior detection performance over a broad optical bandwidth, compatibility with an integrated optical platform is a crucial requirement for applications in emerging quantum photonic technologies. Here we present SNSPDs embedded in nanophotonic integrated circuits which achieve internal quantum efficiencies close to unity at 1550 nm wavelength. This allows for the SNSPDs to be operated at bias currents far below the critical current where unwanted dark count events reach milli-Hz levels while on-chip detection efficiencies above 70% are maintained. The measured dark count rates correspond to noise-equivalent powers in the 10−19 W/Hz−1/2 range and the timing jitter is as low as 35 ps. Our detectors are fully scalable and interface directly with waveguide-based optical platforms. PMID:26061283

  17. Waveguide integrated superconducting single-photon detectors with high internal quantum efficiency at telecom wavelengths.

    PubMed

    Kahl, Oliver; Ferrari, Simone; Kovalyuk, Vadim; Goltsman, Gregory N; Korneev, Alexander; Pernice, Wolfram H P

    2015-06-10

    Superconducting nanowire single-photon detectors (SNSPDs) provide high efficiency for detecting individual photons while keeping dark counts and timing jitter minimal. Besides superior detection performance over a broad optical bandwidth, compatibility with an integrated optical platform is a crucial requirement for applications in emerging quantum photonic technologies. Here we present SNSPDs embedded in nanophotonic integrated circuits which achieve internal quantum efficiencies close to unity at 1550 nm wavelength. This allows for the SNSPDs to be operated at bias currents far below the critical current where unwanted dark count events reach milli-Hz levels while on-chip detection efficiencies above 70% are maintained. The measured dark count rates correspond to noise-equivalent powers in the 10(-19) W/Hz(-1/2) range and the timing jitter is as low as 35 ps. Our detectors are fully scalable and interface directly with waveguide-based optical platforms.

  18. Seasonal and long-term changes in relative abundance of bull sharks from a tourist shark feeding site in Fiji.

    PubMed

    Brunnschweiler, Juerg M; Baensch, Harald

    2011-01-27

    Shark tourism has become increasingly popular, but remains controversial because of major concerns originating from the need of tour operators to use bait or chum to reliably attract sharks. We used direct underwater sampling to document changes in bull shark Carcharhinus leucas relative abundance at the Shark Reef Marine Reserve, a shark feeding site in Fiji, and the reproductive cycle of the species in Fijian waters. Between 2003 and 2009, the total number of C. leucas counted on each day ranged from 0 to 40. Whereas the number of C. leucas counted at the feeding site increased over the years, shark numbers decreased over the course of a calendar year with fewest animals counted in November. Externally visible reproductive status information indicates that the species' seasonal departure from the feeding site may be related to reproductive activity.

  19. Diffusion processes in tumors: A nuclear medicine approach

    NASA Astrophysics Data System (ADS)

    Amaya, Helman

    2016-07-01

    The number of counts used in nuclear medicine imaging techniques, only provides physical information about the desintegration of the nucleus present in the the radiotracer molecules that were uptaken in a particular anatomical region, but that information is not a real metabolic information. For this reason a mathematical method was used to find a correlation between number of counts and 18F-FDG mass concentration. This correlation allows a better interpretation of the results obtained in the study of diffusive processes in an agar phantom, and based on it, an image from the PETCETIX DICOM sample image set from OsiriX-viewer software was processed. PET-CT gradient magnitude and Laplacian images could show direct information on diffusive processes for radiopharmaceuticals that enter into the cells by simple diffusion. In the case of the radiopharmaceutical 18F-FDG is necessary to include pharmacokinetic models, to make a correct interpretation of the gradient magnitude and Laplacian of counts images.

  20. Measurements on a full-field digital mammography system with a photon counting crystalline silicon detector

    NASA Astrophysics Data System (ADS)

    Lundqvist, Mats; Danielsson, Mats; Cederstroem, Bjoern; Chmill, Valery; Chuntonov, Alexander; Aslund, Magnus

    2003-06-01

    Sectra Microdose is the first single photon counting mammography detector. An edge-on crystalline silicon detector is connected to application specific integrated circuits that individually process each photon. The detector is scanned across the breast and the rejection of scattered radiation exceeds 97% without the use of a Bucky. Processing of each x-rays individually enables an optimization of the information transfer from the x-rays to the image in a way previously not possible. Combined with an almost absence of noise from scattered radiation and from electronics we foresee a possibility to reduce the radiation dose and/or increase the image quality. We will discuss fundamental features of the new direct photon counting technique in terms of dose efficiency and present preliminary measurements for a prototype on physical parameters such as Noise Power Spectra (NPS), MTF and DQE.

  1. Development of estimation methodology for bicycle and pedestrian volumes based on existing counts.

    DOT National Transportation Integrated Search

    2013-10-01

    The Colorado Department of Transportation (CDOT) adopted the Bicycle and Pedestrian Policy directive in 2009 : stating that "...the needs of bicyclists and pedestrians shall be included in the planning, design, and operation of : transportation facil...

  2. High-rate x-ray spectroscopy in mammography with a CdTe detector: a digital pulse processing approach.

    PubMed

    Abbene, L; Gerardi, G; Principato, F; Del Sordo, S; Ienzi, R; Raso, G

    2010-12-01

    Direct measurement of mammographic x-ray spectra under clinical conditions is a difficult task due to the high fluence rate of the x-ray beams as well as the limits in the development of high resolution detection systems in a high counting rate environment. In this work we present a detection system, based on a CdTe detector and an innovative digital pulse processing (DPP) system, for high-rate x-ray spectroscopy in mammography. The DPP system performs a digital pile-up inspection and a digital pulse height analysis of the detector signals, digitized through a 14-bit, 100 MHz digitizer, for x-ray spectroscopy even at high photon counting rates. We investigated on the response of the digital detection system both at low (150 cps) and at high photon counting rates (up to 500 kcps) by using monoenergetic x-ray sources and a nonclinical molybdenum anode x-ray tube. Clinical molybdenum x-ray spectrum measurements were also performed by using a pinhole collimator and a custom alignment device. The detection system shows excellent performance up to 512 kcps with an energy resolution of 4.08% FWHM at 22.1 keV. Despite the high photon counting rate (up to 453 kcps), the molybdenum x-ray spectra, measured under clinical conditions, are characterized by a low number of pile-up events. The agreement between the attenuation curves and the half value layer values, obtained from the measured spectra, simulated spectra, and from the exposure values directly measured with an ionization chamber, also shows the accuracy of the measurements. These results make the proposed detection system a very attractive tool for both laboratory research and advanced quality controls in mammography.

  3. A new model to predict weak-lensing peak counts. II. Parameter constraint strategies

    NASA Astrophysics Data System (ADS)

    Lin, Chieh-An; Kilbinger, Martin

    2015-11-01

    Context. Peak counts have been shown to be an excellent tool for extracting the non-Gaussian part of the weak lensing signal. Recently, we developed a fast stochastic forward model to predict weak-lensing peak counts. Our model is able to reconstruct the underlying distribution of observables for analysis. Aims: In this work, we explore and compare various strategies for constraining a parameter using our model, focusing on the matter density Ωm and the density fluctuation amplitude σ8. Methods: First, we examine the impact from the cosmological dependency of covariances (CDC). Second, we perform the analysis with the copula likelihood, a technique that makes a weaker assumption than does the Gaussian likelihood. Third, direct, non-analytic parameter estimations are applied using the full information of the distribution. Fourth, we obtain constraints with approximate Bayesian computation (ABC), an efficient, robust, and likelihood-free algorithm based on accept-reject sampling. Results: We find that neglecting the CDC effect enlarges parameter contours by 22% and that the covariance-varying copula likelihood is a very good approximation to the true likelihood. The direct techniques work well in spite of noisier contours. Concerning ABC, the iterative process converges quickly to a posterior distribution that is in excellent agreement with results from our other analyses. The time cost for ABC is reduced by two orders of magnitude. Conclusions: The stochastic nature of our weak-lensing peak count model allows us to use various techniques that approach the true underlying probability distribution of observables, without making simplifying assumptions. Our work can be generalized to other observables where forward simulations provide samples of the underlying distribution.

  4. Anti-intercellular substance antibody log titres are correlated with serum concentrations of interleukin-6, interleukin-15 and tumor necrosis factor-alpha in patients with Pemphigus vulgaris relationships with peripheral blood neutrophil counts, disease severity and duration and patients' age.

    PubMed

    Ameglio, F; D'Auria, L; Cordiali-Fei, P; Trento, E; D'Agosto, G; Mastroianni, A; Giannetti, A; Giacalone, B

    1999-01-01

    Pemphigus vulgaris is a rare dermatosis of autoimmune origin, characterized by autoantibodies directed against intercellular substance (AICS) and presenting with intra-epidermal blisters and/or erosions of the skin and mucous membranes. The aim of this paper is to analyze the relationships between serum AICS titers (after log transformation) and: patients' age, disease duration and disease activity; serum cytokine (IL-6, IL-7, IL-15 and TNF-alpha) concentrations and peripheral blood cell counts (namely neutrophils, lymphocytes and natural killer cells). Fifteen consecutive subjects affected with PV were enrolled. Diagnosis was supported by histological examination as well as by direct and indirect immunofluorescence tests. Cytokine determinations were made by means of commercially available ELISA kits. This study shows for the first time that AICS titers have a significant correlation with age of PV patients (R=0.57, p=0.031) and with the disease duration (R=0.73, p=0.002). A correlation between blood neutrophils count and log (AICS) titres was observed (R=0.6, p=0.021). Furthermore, significant correlations were observed between log (AICS) titres and serum IL-15 (R=0.54, p=0.048), serum IL-6 (R=0.53, p=0.05) or serum TNF-alpha concentrations (R=0.53, p=0.05). These data, taken together, show that there are several connections between the log (AICS) titres, some proinflammatory cytokines, peripheral blood neutrophil counts and the numbers of individuals' lesions, suggesting a relationship between AICS production and lesion development.

  5. Relationship of Terminal Duct Lobular Unit Involution of the Breast with Area and Volume Mammographic Densities

    PubMed Central

    Gierach, Gretchen L.; Patel, Deesha A.; Pfeiffer, Ruth M.; Figueroa, Jonine D.; Linville, Laura; Papathomas, Daphne; Johnson, Jason M.; Chicoine, Rachael E.; Herschorn, Sally D.; Shepherd, John A.; Wang, Jeff; Malkov, Serghei; Vacek, Pamela M.; Weaver, Donald L.; Fan, Bo; Mahmoudzadeh, Amir Pasha; Palakal, Maya; Xiang, Jackie; Oh, Hannah; Horne, Hisani N.; Sprague, Brian L.; Hewitt, Stephen M.; Brinton, Louise A.; Sherman, Mark E.

    2016-01-01

    Elevated mammographic density (MD) is an established breast cancer risk factor. Reduced involution of terminal duct lobular units (TDLUs), the histologic source of most breast cancers, has been associated with higher MD and breast cancer risk. We investigated relationships of TDLU involution with area and volumetric MD, measured throughout the breast and surrounding biopsy targets (peri-lesional). Three measures inversely related to TDLU involution (TDLU count/mm2, median TDLU span, median acini count/TDLU) assessed in benign diagnostic biopsies from 348 women, ages 40–65, were related to MD area (quantified with thresholding software) and volume (assessed with a density phantom) by analysis of covariance, stratified by menopausal status and adjusted for confounders. Among premenopausal women, TDLU count was directly associated with percent peri-lesional MD (P-trend=0.03), but not with absolute dense area/volume. Greater TDLU span was associated with elevated percent dense area/volume (P-trend<0.05) and absolute peri-lesional MD (P=0.003). Acini count was directly associated with absolute peri-lesional MD (P=0.02). Greater TDLU involution (all metrics) was associated with increased nondense area/volume (P-trend≤0.04). Among postmenopausal women, TDLU measures were not significantly associated with MD. Among premenopausal women, reduced TDLU involution was associated with higher area and volumetric MD, particularly in peri-lesional parenchyma. Data indicating that TDLU involution and MD are correlated markers of breast cancer risk suggest that associations of MD with breast cancer may partly reflect amounts of at-risk epithelium. If confirmed, these results could suggest a prevention paradigm based on enhancing TDLU involution and monitoring efficacy by assessing MD reduction. PMID:26645278

  6. Trend estimation in populations with imperfect detection

    USGS Publications Warehouse

    Kery, Marc; Dorazio, Robert M.; Soldaat, Leo; Van Strien, Arco; Zuiderwijk, Annie; Royle, J. Andrew

    2009-01-01

    1. Trends of animal populations are of great interest in ecology but cannot be directly observed owing to imperfect detection. Binomial mixture models use replicated counts to estimate abundance, corrected for detection, in demographically closed populations. Here, we extend these models to open populations and illustrate them using sand lizard Lacerta agilis counts from the national Dutch reptile monitoring scheme. 2. Our model requires replicated counts from multiple sites in each of several periods, within which population closure is assumed. Counts are described by a hierarchical generalized linear model, where the state model deals with spatio-temporal patterns in true abundance and the observation model with imperfect counts, given that true state. We used WinBUGS to fit the model to lizard counts from 208 transects with 1–10 (mean 3) replicate surveys during each spring 1994–2005. 3. Our state model for abundance contained two independent log-linear Poisson regressions on year for coastal and inland sites, and random site effects to account for unexplained heterogeneity. The observation model for detection of an individual lizard contained effects of region, survey date, temperature, observer experience and random survey effects. 4. Lizard populations increased in both regions but more steeply on the coast. Detectability increased over the first few years of the study, was greater on the coast and for the most experienced observers, and highest around 1 June. Interestingly, the population increase inland was not detectable when the observed counts were analysed without account of detectability. The proportional increase between 1994 and 2005 in total lizard abundance across all sites was estimated at 86% (95% CRI 35–151). 5. Synthesis and applications. Open-population binomial mixture models are attractive for studying true population dynamics while explicitly accounting for the observation process, i.e. imperfect detection. We emphasize the important conceptual benefit provided by temporal replicate observations in terms of the interpretability of animal counts.

  7. Incorporating availability for detection in estimates of bird abundance

    USGS Publications Warehouse

    Diefenbach, D.R.; Marshall, M.R.; Mattice, J.A.; Brauning, D.W.

    2007-01-01

    Several bird-survey methods have been proposed that provide an estimated detection probability so that bird-count statistics can be used to estimate bird abundance. However, some of these estimators adjust counts of birds observed by the probability that a bird is detected and assume that all birds are available to be detected at the time of the survey. We marked male Henslow's Sparrows (Ammodramus henslowii) and Grasshopper Sparrows (A. savannarum) and monitored their behavior during May-July 2002 and 2003 to estimate the proportion of time they were available for detection. We found that the availability of Henslow's Sparrows declined in late June to <10% for 5- or 10-min point counts when a male had to sing and be visible to the observer; but during 20 May-19 June, males were available for detection 39.1% (SD = 27.3) of the time for 5-min point counts and 43.9% (SD = 28.9) of the time for 10-min point counts (n = 54). We detected no temporal changes in availability for Grasshopper Sparrows, but estimated availability to be much lower for 5-min point counts (10.3%, SD = 12.2) than for 10-min point counts (19.2%, SD = 22.3) when males had to be visible and sing during the sampling period (n = 80). For distance sampling, we estimated the availability of Henslow's Sparrows to be 44.2% (SD = 29.0) and the availability of Grasshopper Sparrows to be 20.6% (SD = 23.5). We show how our estimates of availability can be incorporated in the abundance and variance estimators for distance sampling and modify the abundance and variance estimators for the double-observer method. Methods that directly estimate availability from bird counts but also incorporate detection probabilities need further development and will be important for obtaining unbiased estimates of abundance for these species.

  8. Half-Lives of 101Rh and 108m Ag

    NASA Astrophysics Data System (ADS)

    Norman, Eric; Browne, Edgardo; Shugart, Howard

    2014-09-01

    Half-lives of short-lived nuclei can easily be measured by direct counting techniques, whereas those of long-lived naturally-occurring nuclei are usually determined by specific activity measurements. However, half-lives in the range of 1 - 1,000,000 years are notoriously difficult to determine. For example, published values for the half-life of 101Rh range from 3.0 +/- 0.4 years to 10 +/- 1 years, and for 108m Ag published values range from 127 +/- 21 years to 438 +/- 9 years. In order to resolve the issues of what the half-lives of these isotopes actually are, we set up two separate long-term gamma-ray counting experiments. Gamma-ray data were collected in time bins using high-purity Ge detectors and ORTEC PC-based data acquisition systems. We counted in this manner for a period of approximately 5 years for 101Rh and 3 years for 108mAg. In this talk we will describe the details of these experiments and will present the final results for the half-lives of 101Rh and 108mAg determined from these measurements. Half-lives of short-lived nuclei can easily be measured by direct counting techniques, whereas those of long-lived naturally-occurring nuclei are usually determined by specific activity measurements. However, half-lives in the range of 1 - 1,000,000 years are notoriously difficult to determine. For example, published values for the half-life of 101Rh range from 3.0 +/- 0.4 years to 10 +/- 1 years, and for 108m Ag published values range from 127 +/- 21 years to 438 +/- 9 years. In order to resolve the issues of what the half-lives of these isotopes actually are, we set up two separate long-term gamma-ray counting experiments. Gamma-ray data were collected in time bins using high-purity Ge detectors and ORTEC PC-based data acquisition systems. We counted in this manner for a period of approximately 5 years for 101Rh and 3 years for 108mAg. In this talk we will describe the details of these experiments and will present the final results for the half-lives of 101Rh and 108mAg determined from these measurements. This work was supported in part by the U. S. Dept. of Energy under Contract Numbers DE-AC02-05CH11231 and DE-NA0000979.

  9. Daily step count predicts acute exacerbations in a US cohort with COPD.

    PubMed

    Moy, Marilyn L; Teylan, Merilee; Weston, Nicole A; Gagnon, David R; Garshick, Eric

    2013-01-01

    COPD is characterized by variability in exercise capacity and physical activity (PA), and acute exacerbations (AEs). Little is known about the relationship between daily step count, a direct measure of PA, and the risk of AEs, including hospitalizations. In an observational cohort study of 169 persons with COPD, we directly assessed PA with the StepWatch Activity Monitor, an ankle-worn accelerometer that measures daily step count. We also assessed exercise capacity with the 6-minute walk test (6MWT) and patient-reported PA with the St. George's Respiratory Questionnaire Activity Score (SGRQ-AS). AEs and COPD-related hospitalizations were assessed and validated prospectively over a median of 16 months. Mean daily step count was 5804±3141 steps. Over 209 person-years of observation, there were 263 AEs (incidence rate 1.3±1.6 per person-year) and 116 COPD-related hospitalizations (incidence rate 0.56±1.09 per person-year). Adjusting for FEV1 % predicted and prednisone use for AE in previous year, for each 1000 fewer steps per day walked at baseline, there was an increased rate of AEs (rate ratio 1.07; 95%CI = 1.003-1.15) and COPD-related hospitalizations (rate ratio 1.24; 95%CI = 1.08-1.42). There was a significant linear trend of decreasing daily step count by quartiles and increasing rate ratios for AEs (P = 0.008) and COPD-related hospitalizations (P = 0.003). Each 30-meter decrease in 6MWT distance was associated with an increased rate ratio of 1.07 (95%CI = 1.01-1.14) for AEs and 1.18 (95%CI = 1.07-1.30) for COPD-related hospitalizations. Worsening of SGRQ-AS by 4 points was associated with an increased rate ratio of 1.05 (95%CI = 1.01-1.09) for AEs and 1.10 (95%CI = 1.02-1.17) for COPD-related hospitalizations. Lower daily step count, lower 6MWT distance, and worse SGRQ-AS predict future AEs and COPD-related hospitalizations, independent of pulmonary function and previous AE history. These results support the importance of assessing PA in patients with COPD, and provide the rationale to promote PA as part of exacerbation-prevention strategies.

  10. Validity and Reliability of Fitbit Flex for Step Count, Moderate to Vigorous Physical Activity and Activity Energy Expenditure

    PubMed Central

    Sushames, Ashleigh; Edwards, Andrew; Thompson, Fintan; McDermott, Robyn; Gebel, Klaus

    2016-01-01

    Objectives To examine the validity and reliability of the Fitbit Flex against direct observation for measuring steps in the laboratory and against the Actigraph for step counts in free-living conditions and for moderate-to-vigorous physical activity (MVPA) and activity energy expenditure (AEE) overall. Methods Twenty-five adults (12 females, 13 males) wore a Fitbit Flex and an Actigraph GT3X+ during a laboratory based protocol (including walking, incline walking, running and stepping) and free-living conditions during a single day period to examine measurement of steps, AEE and MVPA. Twenty-four of the participants attended a second session using the same protocol. Results Intraclass correlations (ICC) for test-retest reliability of the Fitbit Flex were strong for walking (ICC = 0.57), moderate for stair stepping (ICC = 0.34), and weak for incline walking (ICC = 0.22) and jogging (ICC = 0.26). The Fitbit significantly undercounted walking steps in the laboratory (absolute proportional difference: 21.2%, 95%CI 13.0–29.4%), but it was more accurate, despite slightly over counting, for both jogging (6.4%, 95%CI 3.7–9.0%) and stair stepping (15.5%, 95%CI 10.1–20.9%). The Fitbit had higher coefficients of variation (Cv) for step counts compared to direct observation and the Actigraph. In free-living conditions, the average MVPA minutes were lower in the Fitbit (35.4 minutes) compared to the Actigraph (54.6 minutes), but AEE was greater from the Fitbit (808.1 calories) versus the Actigraph (538.9 calories). The coefficients of variation were similar for AEE for the Actigraph (Cv = 36.0) and Fitbit (Cv = 35.0), but lower in the Actigraph (Cv = 25.5) for MVPA against the Fitbit (Cv = 32.7). Conclusion The Fitbit Flex has moderate validity for measuring physical activity relative to direct observation and the Actigraph. Test-rest reliability of the Fitbit was dependant on activity type and had greater variation between sessions compared to the Actigraph. Physical activity surveillance studies using the Fitbit Flex should consider the potential effect of measurement reactivity and undercounting of steps. PMID:27589592

  11. WE-G-204-03: Photon-Counting Hexagonal Pixel Array CdTe Detector: Optimal Resampling to Square Pixels

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Shrestha, S; Vedantham, S; Karellas, A

    Purpose: Detectors with hexagonal pixels require resampling to square pixels for distortion-free display of acquired images. In this work, the presampling modulation transfer function (MTF) of a hexagonal pixel array photon-counting CdTe detector for region-of-interest fluoroscopy was measured and the optimal square pixel size for resampling was determined. Methods: A 0.65mm thick CdTe Schottky sensor capable of concurrently acquiring up to 3 energy-windowed images was operated in a single energy-window mode to include ≥10 KeV photons. The detector had hexagonal pixels with apothem of 30 microns resulting in pixel spacing of 60 and 51.96 microns along the two orthogonal directions.more » Images of a tungsten edge test device acquired under IEC RQA5 conditions were double Hough transformed to identify the edge and numerically differentiated. The presampling MTF was determined from the finely sampled line spread function that accounted for the hexagonal sampling. The optimal square pixel size was determined in two ways; the square pixel size for which the aperture function evaluated at the Nyquist frequencies along the two orthogonal directions matched that from the hexagonal pixel aperture functions, and the square pixel size for which the mean absolute difference between the square and hexagonal aperture functions was minimized over all frequencies up to the Nyquist limit. Results: Evaluation of the aperture functions over the entire frequency range resulted in square pixel size of 53 microns with less than 2% difference from the hexagonal pixel. Evaluation of the aperture functions at Nyquist frequencies alone resulted in 54 microns square pixels. For the photon-counting CdTe detector and after resampling to 53 microns square pixels using quadratic interpolation, the presampling MTF at Nyquist frequency of 9.434 cycles/mm along the two directions were 0.501 and 0.507. Conclusion: Hexagonal pixel array photon-counting CdTe detector after resampling to square pixels provides high-resolution imaging suitable for fluoroscopy.« less

  12. The association between white blood cell count and acute myocardial infarction in-hospital mortality: findings from the National Registry of Myocardial Infarction.

    PubMed

    Grzybowski, Mary; Welch, Robert D; Parsons, Lori; Ndumele, Chiadi E; Chen, Edmond; Zalenski, Robert; Barron, Hal V

    2004-10-01

    Although cross-sectional and prospective studies have shown that the white blood cell (WBC) count is associated with long-term mortality for patients with ischemic heart disease, the role of the WBC count as an independent predictor of short-term mortality in patients with acute myocardial infarction (AMI) has not been examined as extensively. The objective of this study was to determine whether the WBC count is associated with in-hospital mortality for patients with ischemic heart disease after controlling for potential confounders. From July 31, 2000, to July 31, 2001, the National Registry of Myocardial Infarction 4 enrolled 186,727 AMI patients. A total of 115,273 patients were included in the analysis. WBC counts were subdivided into intervals of 1,000/mL, and in-hospital mortality rates were determined for each interval. The distribution revealed a J-shaped curve. Patients with WBC counts >5,000/mL were subdivided into quartiles, whereas patients with WBC counts <5,000/mL were assigned to a separate category labeled "subquartile" and were analyzed separately. A linear increase in in-hospital mortality by WBC count quartile was found. The unadjusted odds ratio (OR) for the fourth versus the first quartile showed strong associations with in-hospital mortality among the entire population and by gender: 4.09 (95% confidence interval [95% CI] = 3.83 to 4.73) for all patients, 4.31 (95% CI = 3.93 to 4.73) for men, and 3.65 (95% CI = 3.32 to 4.01) for women. Following adjustment for covariates, the magnitude of the ORs attenuated, but the ORs remained highly significant (OR, 2.71 [95% CI = 2.53 to 2.90] for all patients; OR, 2.87 [95% CI = 2.59 to 3.19] for men; OR, 2.61 [95% CI = 2.36 to 2.99] for women). Reperfused patients had consistently lower in-hospital mortality rates for all patients and by gender (p < 0.0001). The WBC count is an independent predictor of in-hospital AMI mortality and may be useful in assessing the prognosis of AMI in conjunction with other early risk-stratification factors. Whether elevated WBC count is a marker of the inflammatory process or is a direct risk factor for AMI remains unclear. Given the simplicity and availability of the WBC count, the authors conclude that the WBC count should be used in conjunction with other ancillary tests to assess the prognosis of a patient with AMI.

  13. Deriving simple empirical relationships between aerodynamic and optical aerosol measurements and their application

    USDA-ARS?s Scientific Manuscript database

    Different measurement techniques for aerosol characterization and quantification either directly or indirectly measure different aerosol properties (i.e. count, mass, speciation, etc.). Comparisons and combinations of multiple measurement techniques sampling the same aerosol can provide insight into...

  14. Swift Confirmation of new transient activity in NGC 6440

    NASA Astrophysics Data System (ADS)

    Bahramian, A.; Kennea, J. A.; Altamirano, D.; Beri, Aru; Heinke, C. O.; Sivakoff, G. R.; Tetarenko, A. J.; Wijnands, Rudy; Degenaar, Nathalie

    2017-10-01

    Following report of enhanced X-ray brightness from the direction of the globular cluster NGC 6440 (ATel #10821), we observed this cluster on 2017-10-05 18:52:35 UT for 1.5 ks with Swift/XRT in Photon Counting mode.

  15. Development of a nematode offspring counting assay for rapid and simple soil toxicity assessment.

    PubMed

    Kim, Shin Woong; Moon, Jongmin; Jeong, Seung-Woo; An, Youn-Joo

    2018-05-01

    Since the introduction of standardized nematode toxicity assays by the American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO), many studies have reported their use. Given that the currently used standardized nematode toxicity assays have certain limitations, in this study, we examined the use of a novel nematode offspring counting assay for evaluating soil ecotoxicity based on a previous soil-agar isolation method used to recover live adult nematodes. In this new assay, adult Caenorhabditis elegans were exposed to soil using a standardized toxicity assay procedure, and the resulting offspring in test soils attracted by a microbial food source in agar plates were counted. This method differs from previously used assays in terms of its endpoint, namely, the number of nematode offspring. The applicability of the bioassay was demonstrated using metal-spiked soils, which revealed metal concentration-dependent responses, and with 36 field soil samples characterized by different physicochemical properties and containing various metals. Principal component analysis revealed that texture fraction (clay, sand, and silt) and electrical conductivity values were the main factors influencing the nematode offspring counting assay, and these findings warrant further investigation. The nematode offspring counting assay is a rapid and simple process that can provide multi-directional toxicity assessment when used in conjunction with other standard methods. Copyright © 2018 Elsevier Ltd. All rights reserved.

  16. Elevated leukocyte count is associated with periodontitis in Korean adults: the 2012-2014 KNHANES.

    PubMed

    Kwon, Y-J; Jeon, K-J; Chung, T-H; Lee, Y-J

    2017-03-01

    Both an elevated leukocyte count and periodontitis share well-recognized associations with cardiometabolic diseases. This cross-sectional study aimed to identify whether the leukocyte count is associated with periodontitis in a nationally representative Korean adult population. Data from 9391 participants (3659 males and 5732 females) enrolled in 2012-2014 Korean National Health and Nutrition Examination Survey were analyzed. Leukocyte quartiles were categorized as follows: 3000 ≤ Q1 ≤ 4870, 4880 ≤ Q2 ≤5790, 5800 ≤ Q3 ≤ 6840, and 6850 ≤ Q4 ≤ 10000 cells/μl. Periodontitis was defined as scoring greater than or equal to 'code 3' in at least one site according to the WHO's Community Periodontal Index. The odds ratios (ORs) and 95% confidence intervals (95% CIs) for periodontitis in each leukocyte count quartile were calculated using multiple logistic regression analyses. The prevalence of periodontitis was directly correlated with increasing leukocyte quartiles: 19%, 20.4%, 24.3%, and 30.3%. Compared with the lowest leukocyte quartile group, the OR (95% CI) for periodontitis of the highest leukocyte quartile was 1.558 (1.285-1.891) after controlling for confounding factors. An elevated leukocyte count was positively associated with the presence of periodontitis. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  17. Microbiological contamination of cubicle curtains in an out-patient podiatry clinic

    PubMed Central

    2010-01-01

    Background Exposure to potential pathogens on contaminated healthcare garments and curtains can occur through direct or indirect contact. This study aimed to identify the microorganisms present on podiatry clinic curtains and measure the contamination pre and post a standard hospital laundry process. Method Baseline swabs were taken to determine colony counts present on cubical curtains before laundering. Curtains were swabbed again immediately after, one and three weeks post laundering. Total colony counts were calculated and compared to baseline, with identification of micro-organisms. Results Total colony counts increased very slightly by 3% immediately after laundry, which was not statistically significant, and declined significantly (p = 0.0002) by 56% one-week post laundry. Three weeks post laundry colony counts had increased by 16%; although clinically relevant, this was not statistically significant. The two most frequent microorganisms present throughout were Coagulase Negative Staphylococcus and Micrococcus species. Laundering was not completely effective, as both species demonstrated no significant change following laundry. Conclusion This work suggests current laundry procedures may not be 100% effective in killing all microorganisms found on curtains, although a delayed decrease in total colony counts was evident. Cubicle curtains may act as a reservoir for microorganisms creating potential for cross contamination. This highlights the need for additional cleaning methods to decrease the risk of cross infection and the importance of maintaining good hand hygiene. PMID:21087486

  18. Phase space representation of neutron monitor count rate and atmospheric electric field in relation to solar activity in cycles 21 and 22.

    PubMed

    Silva, H G; Lopes, I

    Heliospheric modulation of galactic cosmic rays links solar cycle activity with neutron monitor count rate on earth. A less direct relation holds between neutron monitor count rate and atmospheric electric field because different atmospheric processes, including fluctuations in the ionosphere, are involved. Although a full quantitative model is still lacking, this link is supported by solid statistical evidence. Thus, a connection between the solar cycle activity and atmospheric electric field is expected. To gain a deeper insight into these relations, sunspot area (NOAA, USA), neutron monitor count rate (Climax, Colorado, USA), and atmospheric electric field (Lisbon, Portugal) are presented here in a phase space representation. The period considered covers two solar cycles (21, 22) and extends from 1978 to 1990. Two solar maxima were observed in this dataset, one in 1979 and another in 1989, as well as one solar minimum in 1986. Two main observations of the present study were: (1) similar short-term topological features of the phase space representations of the three variables, (2) a long-term phase space radius synchronization between the solar cycle activity, neutron monitor count rate, and potential gradient (confirmed by absolute correlation values above ~0.8). Finally, the methodology proposed here can be used for obtaining the relations between other atmospheric parameters (e.g., solar radiation) and solar cycle activity.

  19. Single-photon counting multicolor multiphoton fluorescence microscope.

    PubMed

    Buehler, Christof; Kim, Ki H; Greuter, Urs; Schlumpf, Nick; So, Peter T C

    2005-01-01

    We present a multicolor multiphoton fluorescence microscope with single-photon counting sensitivity. The system integrates a standard multiphoton fluorescence microscope, an optical grating spectrograph operating in the UV-Vis wavelength region, and a 16-anode photomultiplier tube (PMT). The major technical innovation is in the development of a multichannel photon counting card (mC-PhCC) for direct signal collection from multi-anode PMTs. The electronic design of the mC-PhCC employs a high-throughput, fully-parallel, single-photon counting scheme along with a high-speed electrical or fiber-optical link interface to the data acquisition computer. There is no electronic crosstalk among the detection channels of the mC-PhCC. The collected signal remains linear up to an incident photon rate of 10(8) counts per second. The high-speed data interface offers ample bandwidth for real-time readout: 2 MByte lambda-stacks composed of 16 spectral channels, 256 x 256 pixel image with 12-bit dynamic range can be transferred at 30 frames per second. The modular design of the mC-PhCC can be readily extended to accommodate PMTs of more anodes. Data acquisition from a 64-anode PMT has been verified. As a demonstration of system performance, spectrally resolved images of fluorescent latex spheres and ex-vivo human skin are reported. The multicolor multiphoton microscope is suitable for highly sensitive, real-time, spectrally-resolved three-dimensional imaging in biomedical applications.

  20. Enhanced Methodologies to Enumerate Persons Experiencing Homelessness in a Large Urban Area.

    PubMed

    Troisi, Catherine L; D'Andrea, Ritalinda; Grier, Gary; Williams, Stephen

    2015-10-01

    Homelessness is a public health problem, and persons experiencing homelessness are a vulnerable population. Estimates of the number of persons experiencing homelessness inform funding allocations and services planning and directly determine the ability of a community to intervene effectively in homelessness. The point-in-time (PIT) count presents a logistical problem in large urban areas, particularly those covering a vast geographical area. Working together, academia, local government, and community organizations improved the methodology for the count. Specific enhancements include use of incident command system (ICS), increased number of staging areas/teams, specialized outreach and Special Weapons and Tactics teams, and day-after surveying to collect demographic information. This collaboration and enhanced methodology resulted in a more accurate estimate of the number of persons experiencing homelessness and allowed comparison of findings for 4 years. While initial results showed an increase due to improved counting, the number of persons experiencing homelessness counted for the subsequent years showed significant decrease during the same time period as a "housing first" campaign was implemented. The collaboration also built capacity in each sector: The health department used ICS as a training opportunity; the academics enhanced their community health efforts; the service sector was taught and implemented more rigorous quantitative methods; and the community was exposed to public health as a pragmatic and effective discipline. Improvements made to increase the reliability of the PIT count can be adapted for use in other jurisdictions, leading to improved counts and better evaluation of progress in ending homelessness. © The Author(s) 2015.

  1. Correlation study between osteoporosis and hematopoiesis in the context of adjuvant chemotherapy for breast cancer.

    PubMed

    Schyrr, Frédérica; Wolfer, Anita; Pasquier, Jérôme; Nicoulaz, Anne-Laure; Lamy, Olivier; Naveiras, Olaia

    2018-02-01

    This retrospective study attempts to establish if a correlation exists between osteoporosis and hematopoiesis before and after adjuvant chemotherapy in the context of non-metastatic breast cancer. Osteoporosis is interpreted both as a direct marker of osteoblastic decline and as an indirect marker of increased bone marrow adiposity within the hematopoietic microenvironment. Patients from the "Centre du Sein" at CHUV (Centre Hospitalier Universitaire Vaudois) undergoing adjuvant chemotherapy were included in this study. Evolution of blood counts was studied in correlation with the osteoporosis status. Toxicity of chemotherapy was coded according to published probability of febrile neutropenia. One hundred forty-three women were included: mean age 52.1 ± 12.5 years, mean BMI (body mass index) 24.4 ± 4.1. BMD (bone mineral density) scored osteoporotic in 32% and osteopenic in 45%. Prior to chemotherapy, BMD was positively correlated with neutrophil (p < 0.001) and thrombocyte (p = 0.01) count; TBS (trabecular bone score) was not correlated with blood count. After the first cycle of chemotherapy, an increase of one point in TBS correlated with a decrease of 57% on the time to reach leucocyte nadir (p = 0.004). There was a positive correlation between BMD and risk of infection (p < 0.001). Our data demonstrates an association between osteoporosis and lower blood counts in a younger cohort than previously published, extending it for the first time to neutrophil counts in females. Our results suggest that the healthier the bone, the earlier the lowest leucocyte count value, prompting further research on this area.

  2. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, R.B.; Tyree, W.H.

    1982-03-03

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  3. CALCIUM ABSORPTION IN MAN: BASED ON LARGE VOLUME LIQUID SCINTILLATION COUNTER STUDIES.

    PubMed

    LUTWAK, L; SHAPIRO, J R

    1964-05-29

    A technique has been developed for the in vivo measurement of absorption of calcium in man after oral administration of 1 to 5 microcuries of calcium-47 and continuous counting of the radiation in the subject's arm with a large volume liquid scintillation counter. The maximum value for the arm counting technique is proportional to the absorption of tracer as measured by direct stool analysis. The rate of uptake by the arm is lower in subjects with either the malabsorption syndrome or hypoparathyroidism. The administration of vitamin D increases both the absorption rate and the maximum amount of calcium absorbed.

  4. Super resolution imaging of HER2 gene amplification

    NASA Astrophysics Data System (ADS)

    Okada, Masaya; Kubo, Takuya; Masumoto, Kanako; Iwanaga, Shigeki

    2016-02-01

    HER2 positive breast cancer is currently examined by counting HER2 genes using fluorescence in situ hybridization (FISH)-stained breast carcinoma samples. In this research, two-dimensional super resolution fluorescence microscopy based on stochastic optical reconstruction microscopy (STORM), with a spatial resolution of approximately 20 nm in the lateral direction, was used to more precisely distinguish and count HER2 genes in a FISH-stained tissue section. Furthermore, by introducing double-helix point spread function (DH-PSF), an optical phase modulation technique, to super resolution microscopy, three-dimensional images were obtained of HER2 in a breast carcinoma sample approximately 4 μm thick.

  5. Pile-up corrections in laser-driven pulsed X-ray sources

    NASA Astrophysics Data System (ADS)

    Hernández, G.; Fernández, F.

    2018-06-01

    A formalism for treating the pile-up produced in solid-state detectors by laser-driven pulsed X-ray sources has been developed. It allows the direct use of X-ray spectroscopy without artificially decreasing the number of counts in the detector, assuming the duration of a pulse is much shorter than the detector response time and the loss of counts from the energy window of the detector can be modeled or neglected. Experimental application shows that having a small amount of pile-up subsequently corrected improves the signal-to-noise ratio, which would be more beneficial than the strict single-hit condition usually imposed on this detectors.

  6. Counting the number of Feynman graphs in QCD

    NASA Astrophysics Data System (ADS)

    Kaneko, T.

    2018-05-01

    Information about the number of Feynman graphs for a given physical process in a given field theory is especially useful for confirming the result of a Feynman graph generator used in an automatic system of perturbative calculations. A method of counting the number of Feynman graphs with weight of symmetry factor was established based on zero-dimensional field theory, and was used in scalar theories and QED. In this article this method is generalized to more complicated models by direct calculation of generating functions on a computer algebra system. This method is applied to QCD with and without counter terms, where many higher order are being calculated automatically.

  7. Personnel electronic neutron dosimeter

    DOEpatents

    Falk, Roger B.; Tyree, William H.

    1984-12-18

    A personnel electronic dosimeter includes a neutron-proton and neutron-alpha converter for providing an electrical signal having a magnitude proportional to the energy of a detected proton or alpha particle produced from the converter, a pulse generator circuit for generating a pulse having a duration controlled by the weighed effect of the amplitude of the electrical signal, an oscillator enabled by the pulse for generating a train of clock pulses for a time dependent upon the pulse length, a counter for counting the clock pulses, and an indicator for providing a direct reading and aural alarm when the count indicates that the wearer has been exposed to a selected level of neutron dose equivalent.

  8. Solid-state image sensor with focal-plane digital photon-counting pixel array

    NASA Technical Reports Server (NTRS)

    Fossum, Eric R. (Inventor); Pain, Bedabrata (Inventor)

    1995-01-01

    A photosensitive layer such as a-Si for a UV/visible wavelength band is provided for low light level imaging with at least a separate CMOS amplifier directly connected to each PIN photodetector diode to provide a focal-plane array of NxN pixels, and preferably a separate photon-counting CMOS circuit directly connected to each CMOS amplifier, although one row of counters may be time shared for reading out the photon flux rate of each diode in the array, together with a buffer memory for storing all rows of the NxN image frame before transfer to suitable storage. All CMOS circuitry is preferably fabricated in the same silicon layer as the PIN photodetector diode for a monolithic structure, but when the wavelength band of interest requires photosensitive material different from silicon, the focal-plane array may be fabricated separately on a different semiconductor layer bump-bonded or otherwise bonded for a virtually monolithic structure with one free terminal of each diode directly connected to the input terminal of its CMOS amplifier and digital counter for integration of the photon flux rate at each photodetector of the array.

  9. MEASUREMENTS OF AIRBORNE CONCENTRATIONS OF RADON AND THORON DECAY PRODUCTS.

    PubMed

    Chalupnik, S; Skubacz, K; Urban, P; Wysocka, M

    2017-11-01

    Liquid scintillation counting (LSC) is a measuring technique, broadly applied in environmental monitoring of radionuclides. One of the possible applications of LSC is the measurement of radon and thoron decay products. But this method is suitable only for grab sampling. For long-term measurements a different technique can be applied-monitors of potential alpha energy concentration (PAEC) with thermoluminescent detectors (TLD). In these devices, called Alfa-2000 sampling probe, TL detectors (CaSO4:Dy) are applied for alpha particles counting. Three independent heads are placed over the membrane filter in a dust sampler's microcyclone. Such solution enables simultaneous measurements of PAEC and dust content. Moreover, the information which is stored in TLD chips is the energy of alpha particles, not the number of counted particles. Therefore, the readout of TL detector shows directly potential alpha energy, with no dependence on equilibrium factor, etc. This technique, which had been used only for radon decay products measurements, was modified by author to allow simultaneous measurements of radon and thoron PAEC. The LSC method can be used for calibration of portable radon decay products monitors. The LSC method has the advantage to be an absolute one, the TLD method to measure directly the (dose relevant) deposited energy. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  10. Predicting county-level cancer incidence rates and counts in the United States

    PubMed Central

    Yu, Binbing

    2018-01-01

    Many countries, including the United States, publish predicted numbers of cancer incidence and death in current and future years for the whole country. These predictions provide important information on the cancer burden for cancer control planners, policymakers and the general public. Based on evidence from several empirical studies, the joinpoint (segmented-line linear regression) model has been adopted by the American Cancer Society to estimate the number of new cancer cases in the United States and in individual states since 2007. Recently, cancer incidence in smaller geographic regions such as counties and FIPS code regions is of increasing interest by local policymakers. The natural extension is to directly apply the joinpoint model to county-level cancer incidence data. The direct application has several drawbacks and its performance has not been evaluated. To address the concerns, we developed a spatial random-effects joinpoint model for county-level cancer incidence data. The proposed model was used to predict both cancer incidence rates and counts at the county level. The standard joinpoint model and the proposed method were compared through a validation study. The proposed method out-performed the standard joinpoint model for almost all cancer sites, especially for moderate or rare cancer sites and for counties with small population sizes. As an application, we predicted county-level prostate cancer incidence rates and counts for the year 2011 in Connecticut. PMID:23670947

  11. Yolk formation in some Charadriiform birds

    USGS Publications Warehouse

    Roudybush, T.E.; Grau, C.R.; Petersen, M.R.; Ainley, D.G.; Hirsch, K.V.; Gilman, A.P.; Patten, S.M.

    1979-01-01

    By counting and measuring the major ova of breeding birds at autopsy and combining these data with time intervals between ovipositions, rough estimates have been made of the time required to form yolk in some non-captive birds (King 1973). Direct studies have been made in domestic fowl (Gallus gallus var. domesticus; Gilbert 1972), turkeys (Meleagris galloparvo; Bacon and Cherms 1968), and Common quail (Coturnix coturnix; Bacon and Koontz 1971), by feeding the birds a capsule containing dye each day, and counting dye rings in the yolks after the eggs have been hardcooked. Recently developed methods of fixing and staining eggs have revealed differences in yolk deposited during day and night, thus permitting another estimation of the number of days during which yolk was deposited, and without direct contact with the female (Grau 1976). In eggs from chickens and quail that have been fed dyes, yolk that stained darkly with dichromate was shown to be deposited during the active daytime feeding periods, while pale-staining yolk was deposited during the night. Thus, pairs of light and dark rings, which together take a day to be deposited, may be counted to estimate time of yolk formation.In the present study we have applied the yolk ring method of estimating the number of days during which the bulk of the yolk is deposited around the central white core (Grau 1976) to the eggs of some shorebirds, gulls, terns and alcids.

  12. The validity of the ActiPed for physical activity monitoring.

    PubMed

    Brown, D K; Grimwade, D; Martinez-Bussion, D; Taylor, M J D; Gladwell, V F

    2013-05-01

    The ActiPed (FitLinxx) is a uniaxial accelerometer, which objectively measures physical activity, uploads the data wirelessly to a website, allowing participants and researchers to view activity levels remotely. The aim was to validate ActiPed's step count, distance travelled and activity time against direct observation. Further, to compare against pedometer (YAMAX), accelerometer (ActiGraph) and manufacturer's guidelines. 22 participants, aged 28±7 years, undertook 4 protocols, including walking on different surfaces and incremental running protocol (from 2 mph to 8 mph). Bland-Altman plots allowed comparison of direct observation against ActiPed estimates. For step count, the ActiPed showed a low % bias in all protocols: walking on a treadmill (-1.30%), incremental treadmill protocol (-1.98%), walking over grass (-1.67%), and walking over concrete (-0.93%). When differentiating between walking and running step count the ActiPed showed a % bias of 4.10% and -6.30%, respectively. The ActiPed showed >95% accuracy for distance and duration estimations overall, although underestimated distance (p<0.01) for walking over grass and concrete. Overall, the ActiPed showed acceptable levels of accuracy comparable to previous validated pedometers and accelerometers. The accuracy combined with the simple and informative remote gathering of data, suggests that the ActiPed could be a useful tool in objective physical activity monitoring. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Detecting and Analyzing Multiple Moving Objects in Crowded Environments with Coherent Motion Regions

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Cheriyadat, Anil M.

    Understanding the world around us from large-scale video data requires vision systems that can perform automatic interpretation. While human eyes can unconsciously perceive independent objects in crowded scenes and other challenging operating environments, automated systems have difficulty detecting, counting, and understanding their behavior in similar scenes. Computer scientists at ORNL have a developed a technology termed as "Coherent Motion Region Detection" that invloves identifying multiple indepedent moving objects in crowded scenes by aggregating low-level motion cues extracted from moving objects. Humans and other species exploit such low-level motion cues seamlessely to perform perceptual grouping for visual understanding. The algorithm detectsmore » and tracks feature points on moving objects resulting in partial trajectories that span coherent 3D region in the space-time volume defined by the video. In the case of multi-object motion, many possible coherent motion regions can be constructed around the set of trajectories. The unique approach in the algorithm is to identify all possible coherent motion regions, then extract a subset of motion regions based on an innovative measure to automatically locate moving objects in crowded environments.The software reports snapshot of the object, count, and derived statistics ( count over time) from input video streams. The software can directly process videos streamed over the internet or directly from a hardware device (camera).« less

  14. Direct anthelmintic effects of Cereus jamacaru (Cactaceae) on trichostrongylid nematodes of sheep: in vivo studies.

    PubMed

    Vatta, A F; Kandu-Lelo, C; Ademola, I O; Eloff, J N

    2011-08-25

    Following claims of anthelmintic activity of Cereus jamacaru DC (Cactaceae) by a commercial farmer, in vivo studies were conducted to determine the possible direct anthelmintic effects of the plant on ovine gastrointestinal nematodes. Eighteen sheep were infected with 4000 Haemonchus contortus and 6000 Trichostrongylus colubriformis larvae given in three divided doses over a period of three days. Once the infections were patent, the sheep were allocated to three groups and were drenched once a week for six weeks with fresh blended C. jamacaru plant material at a single (32.3g/sheep) or double dose (64.6g/sheep) or they remained as undrenched controls. Faeces were collected from individual animals on the day of treatment and three days thereafter on a weekly basis for seven weeks for faecal egg count. While there were no statistically significant differences in the egg counts between the groups, a double dose of C. jamacaru was effective in reducing the egg counts in the sheep by 18-65% over the 49 days of the experiment. Given that all animals remained in good health throughout the course of the experiment, with no adverse events occurring during the study, further experiments using higher doses or administering the plant material for a longer period of time than in the present study would be warranted. Copyright © 2011 Elsevier B.V. All rights reserved.

  15. Platelet antibody in prolonged remission of childhood idiopathic thrombocytopenic purpura

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Ware, R.; Kinney, T.R.; Rosse, W.

    1985-11-01

    Evaluations were performed in 20 patients with childhood idiopathic thrombocytopenic purpura (ITP) who remained in remission longer than 12 months. The mean duration of follow-up from diagnosis was 39 months (range 17 to 87 months). Eleven patients (four girls) in group 1 had an acute course of ITP, defined as platelet count greater than 150 X 10(9)/L within 6 months of diagnosis. Nine patients (five girls) in group 2 had a chronic course, defined as platelet count less than 150 X 10(9)/L for greater than or equal to 1 year or requiring splenectomy in an attempt to control hemorrhagic symptoms.more » Platelet count and serum (indirect) platelet-associated IgG (PAIgG) levels were normal in all 20 patients at follow-up. Both direct and indirect PAIgG levels were measured using a SVI-monoclonal anti-IgG antiglobulin assay. All had normal direct PAIgG levels, except for one patient in group 1 who had a borderline elevated value of 1209 molecules per platelet. These data suggest that the prevalence of elevated platelet antibodies is low during sustained remission without medication in patients with a history of childhood ITP. These data may be relevant for pregnant women with a history of childhood ITP, with regard to the risk of delivering an infant with thrombocytopenia secondary to transplacental passage of maternal platelet antibody.« less

  16. Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory

    NASA Astrophysics Data System (ADS)

    Aab, A.; Abreu, P.; Aglietta, M.; Ahn, E. J.; Samarai, I. Al; Albuquerque, I. F. M.; Allekotte, I.; Allison, P.; Almela, A.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Ambrosio, M.; Anastasi, G. A.; Anchordoqui, L.; Andrada, B.; Andringa, S.; Aramo, C.; Arqueros, F.; Arsene, N.; Asorey, H.; Assis, P.; Aublin, J.; Avila, G.; Badescu, A. M.; Balaceanu, A.; Baus, C.; Beatty, J. J.; Becker, K. H.; Bellido, J. A.; Berat, C.; Bertaina, M. E.; Bertou, X.; Biermann, P. L.; Billoir, P.; Biteau, J.; Blaess, S. G.; Blanco, A.; Blazek, J.; Bleve, C.; Boháčová, M.; Boncioli, D.; Bonifazi, C.; Borodai, N.; Botti, A. M.; Brack, J.; Brancus, I.; Bretz, T.; Bridgeman, A.; Briechle, F. L.; Buchholz, P.; Bueno, A.; Buitink, S.; Buscemi, M.; Caballero-Mora, K. S.; Caccianiga, B.; Caccianiga, L.; Cancio, A.; Canfora, F.; Caramete, L.; Caruso, R.; Castellina, A.; Cataldi, G.; Cazon, L.; Cester, R.; Chavez, A. G.; Chiavassa, A.; Chinellato, J. A.; Chudoba, J.; Clay, R. W.; Colalillo, R.; Coleman, A.; Collica, L.; Coluccia, M. R.; Conceição, R.; Contreras, F.; Cooper, M. J.; Coutu, S.; Covault, C. E.; Cronin, J.; Dallier, R.; D'Amico, S.; Daniel, B.; Dasso, S.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; de Jong, S. J.; De Mauro, G.; de Mello Neto, J. R. T.; De Mitri, I.; de Oliveira, J.; de Souza, V.; Debatin, J.; del Peral, L.; Deligny, O.; Di Giulio, C.; Di Matteo, A.; Díaz Castro, M. L.; Diogo, F.; Dobrigkeit, C.; D'Olivo, J. C.; Dorofeev, A.; dos Anjos, R. C.; Dova, M. T.; Dundovic, A.; Ebr, J.; Engel, R.; Erdmann, M.; Erfani, M.; Escobar, C. O.; Espadanal, J.; Etchegoyen, A.; Falcke, H.; Fang, K.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Fick, B.; Figueira, J. M.; Filevich, A.; Filipčič, A.; Fratu, O.; Freire, M. M.; Fujii, T.; Fuster, A.; García, B.; Garcia-Pinto, D.; Gaté, F.; Gemmeke, H.; Gherghel-Lascu, A.; Ghia, P. L.; Giaccari, U.; Giammarchi, M.; Giller, M.; Głas, D.; Glaser, C.; Glass, H.; Golup, G.; Gómez Berisso, M.; Gómez Vitale, P. F.; González, N.; Gookin, B.; Gordon, J.; Gorgi, A.; Gorham, P.; Gouffon, P.; Grillo, A. F.; Grubb, T. D.; Guarino, F.; Guedes, G. P.; Hampel, M. R.; Hansen, P.; Harari, D.; Harrison, T. A.; Harton, J. L.; Hasankiadeh, Q.; Haungs, A.; Hebbeker, T.; Heck, D.; Heimann, P.; Herve, A. E.; Hill, G. C.; Hojvat, C.; Holt, E.; Homola, P.; Hörandel, J. R.; Horvath, P.; Hrabovský, M.; Huege, T.; Hulsman, J.; Insolia, A.; Isar, P. G.; Jandt, I.; Jansen, S.; Johnsen, J. A.; Josebachuili, M.; Kääpä, A.; Kambeitz, O.; Kampert, K. H.; Kasper, P.; Katkov, I.; Keilhauer, B.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Krause, R.; Krohm, N.; Kuempel, D.; Kukec Mezek, G.; Kunka, N.; Kuotb Awad, A.; LaHurd, D.; Latronico, L.; Lauscher, M.; Lebrun, P.; Legumina, R.; Leigui de Oliveira, M. A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Link, K.; Lopes, L.; López, R.; López Casado, A.; Luce, Q.; Lucero, A.; Malacari, M.; Mallamaci, M.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Mariş, I. C.; Marsella, G.; Martello, D.; Martinez, H.; Martínez Bravo, O.; Masías Meza, J. J.; Mathes, H. J.; Mathys, S.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Mayotte, E.; Mazur, P. O.; Medina, C.; Medina-Tanco, G.; Melo, D.; Menshikov, A.; Messina, S.; Micheletti, M. I.; Middendorf, L.; Minaya, I. A.; Miramonti, L.; Mitrica, B.; Mockler, D.; Molina-Bueno, L.; Mollerach, S.; Montanet, F.; Morello, C.; Mostafá, M.; Müller, G.; Muller, M. A.; Müller, S.; Naranjo, I.; Navas, S.; Nellen, L.; Neuser, J.; Nguyen, P. H.; Niculescu-Oglinzanu, M.; Niechciol, M.; Niemietz, L.; Niggemann, T.; Nitz, D.; Nosek, D.; Novotny, V.; Nožka, H.; Núñez, L. A.; Ochilo, L.; Oikonomou, F.; Olinto, A.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Papenbreer, P.; Parente, G.; Parra, A.; Paul, T.; Pech, M.; Pedreira, F.; Pȩkala, J.; Pelayo, R.; Peña-Rodriguez, J.; Pereira, L. A. S.; Perrone, L.; Peters, C.; Petrera, S.; Phuntsok, J.; Piegaia, R.; Pierog, T.; Pieroni, P.; Pimenta, M.; Pirronello, V.; Platino, M.; Plum, M.; Porowski, C.; Prado, R. R.; Privitera, P.; Prouza, M.; Quel, E. J.; Querchfeld, S.; Quinn, S.; Ramos-Pollant, R.; Rautenberg, J.; Ravignani, D.; Reinert, D.; Revenu, B.; Ridky, J.; Risse, M.; Ristori, P.; Rizi, V.; Rodrigues de Carvalho, W.; Rodriguez Fernandez, G.; Rodriguez Rojo, J.; Rodríguez-Frías, M. D.; Rogozin, D.; Rosado, J.; Roth, M.; Roulet, E.; Rovero, A. C.; Saffi, S. J.; Saftoiu, A.; Salazar, H.; Saleh, A.; Salesa Greus, F.; Salina, G.; Sanabria Gomez, J. D.; Sánchez, F.; Sanchez-Lucas, P.; Santos, E. M.; Santos, E.; Sarazin, F.; Sarkar, B.; Sarmento, R.; Sarmiento-Cano, C.; Sato, R.; Scarso, C.; Schauer, M.; Scherini, V.; Schieler, H.; Schmidt, D.; Scholten, O.; Schovánek, P.; Schröder, F. G.; Schulz, A.; Schulz, J.; Schumacher, J.; Sciutto, S. J.; Segreto, A.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sigl, G.; Silli, G.; Sima, O.; Śmiałkowski, A.; Šmída, R.; Snow, G. R.; Sommers, P.; Sonntag, S.; Sorokin, J.; Squartini, R.; Stanca, D.; Stanič, S.; Stasielak, J.; Strafella, F.; Suarez, F.; Suarez Durán, M.; Sudholz, T.; Suomijärvi, T.; Supanitsky, A. D.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Taborda, O. A.; Tapia, A.; Tepe, A.; Theodoro, V. M.; Timmermans, C.; Todero Peixoto, C. J.; Tomankova, L.; Tomé, B.; Tonachini, A.; Torralba Elipe, G.; Torres Machado, D.; Torri, M.; Travnicek, P.; Trini, M.; Ulrich, R.; Unger, M.; Urban, M.; Valbuena-Delgado, A.; Valdés Galicia, J. F.; Valiño, I.; Valore, L.; van Aar, G.; van Bodegom, P.; van den Berg, A. M.; van Vliet, A.; Varela, E.; Vargas Cárdenas, B.; Varner, G.; Vázquez, J. R.; Vázquez, R. A.; Veberič, D.; Verzi, V.; Vicha, J.; Villaseñor, L.; Vorobiov, S.; Wahlberg, H.; Wainberg, O.; Walz, D.; Watson, A. A.; Weber, M.; Weindl, A.; Wiencke, L.; Wilczyński, H.; Winchen, T.; Wittkowski, D.; Wundheiler, B.; Wykes, S.; Yang, L.; Yelos, D.; Yushkov, A.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zepeda, A.; Zimmermann, B.; Ziolkowski, M.; Zong, Z.; Zuccarello, F.

    2017-03-01

    AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.

  17. Thrombocytopenia after liver transplantation: Should we care?

    PubMed Central

    Takahashi, Kazuhiro; Nagai, Shunji; Safwan, Mohamed; Liang, Chen; Ohkohchi, Nobuhiro

    2018-01-01

    Transient thrombocytopenia is a common phenomenon after liver transplantation. After liver transplantation (LT), platelet count decreases and reaches a nadir on postoperative days 3-5, with an average reduction in platelet counts of 60%; platelet count recovers to preoperative levels approximately two weeks after LT. The putative mechanisms include haemodilution, decreased platelet production, increased sequestration, medications, infections, thrombosis, or combination of these processes. However, the precise mechanisms remain unclear. The role of platelets in liver transplantation has been highlighted in recent years, and particular attention has been given to their effects beyond hemostasis and thrombosis. Previous studies have demonstrated that perioperative thrombocytopenia causes poor graft regeneration, increases the incidence of postoperative morbidity, and deteriorates the graft and decreases patient survival in both the short and long term after liver transplantation. Platelet therapies to increase perioperative platelet counts, such as thrombopoietin, thrombopoietin receptor agonist, platelet transfusion, splenectomy, and intravenous immunoglobulin treatment might have a potential for improving graft survival, however clinical trials are lacking. Further studies are warranted to detect direct evidence on whether thrombocytopenia is the cause or result of poor-graft function and postoperative complications, and to determine who needs platelet therapies in order to prevent postoperative complications and thus improve post-transplant outcomes. PMID:29632420

  18. Counting states and the Hadron Resonance Gas: Does X(3872) count?

    NASA Astrophysics Data System (ADS)

    Ortega, Pablo G.; Entem, David R.; Fernández, Francisco; Ruiz Arriola, Enrique

    2018-06-01

    We analyze how the renowned X(3872), a weakly bound state right below the DDbar* threshold, should effectively be included in a hadronic representation of the QCD partition function. This can be decided by analyzing the DDbar* scattering phase-shifts in the JPC =1++ channel and their contribution to the level density in the continuum from which the abundance in a hot medium can be determined. We show that in a purely molecular picture the bound state contribution cancels the continuum providing a vanishing occupation number density at finite temperature and the X (3872) does not count below the Quark-Gluon Plasma crossover happening at T ∼ 150 MeV. In contrast, within a coupled-channels approach, for a non vanishing c c bar content the cancellation does not occur due to the onset of the X (3940) which effectively counts as an elementary particle for temperatures above T ≳ 250 MeV. Thus, a direct inclusion of the X (3872) in the Hadron Resonance Gas is not justified. We also estimate the role of this cancellation in X(3872) production in heavy-ion collision experiments in terms of the corresponding pT distribution due to a finite energy resolution.

  19. Correlations between metabolic syndrome, serologic factors, and gallstones

    PubMed Central

    Sang, Jae Hong; Ki, Nam Kyun; Cho, Jae Hwan; Ahn, Jae Ouk; Sunwoo, Jae Gun

    2016-01-01

    [Purpose] This study investigated the serologic factors associated with metabolic syndrome and gallstones. [Subjects and Methods] The study evaluated subjects who visited a health promotion center in Seoul from March 2, 2013 to February 28, 2014, and had undergone abdominal ultrasonography. Height, weight, and blood pressure were measured. Blood sampling was performed for high-density lipoprotein cholesterol, triglyceride, fasting blood glucose, total bilirubin, direct bilirubin, indirect bilirubin, aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, uric acid, total cholesterol, low-density lipoprotein cholesterol, thyroid stimulating hormone, and red and white blood cell counts. We conducted logistic regression analysis to assess the risk factors associated with metabolic syndrome. [Results] The risk factors for metabolic syndrome in men, in order of decreasing weight, were red blood cell count, body mass index, maximum size of gallstones, white blood cell count, waist circumference, and uric acid level. The factors in women, in order of decreasing weight, were red blood cell count, presence/absence of gallstones, uric acid level, body mass index, fasting blood glucose, and waist circumference. [Conclusion] Most serum biochemical factors and gallstone occurrence could be used to indicate the presence or absence of metabolic syndrome, independent of gender. PMID:27630427

  20. Interference of blood leucocytes in the measurements of immature red cells (reticulocytes) by two different (semi-) automated flow-cytometry technologies.

    PubMed

    Villamor, N; Kirsch, A; Huhn, D; Vives-Corrons, J L; Serke, S

    1996-06-01

    Flow cytometrical methods have been introduced recently as an alternative to the enumeration of reticulocytes by microscopy. Two of these methods have gained widespread use in haematological practice; the multiparametric flow cytometer using thiazole orange staining (Retic-Count, FACScan) and the single-application reticulocyte counter using auramine-O staining (R-series, Sysmex). Several studies have emphasized the excellent correlations between microscopy and these techniques. The purpose of our study has been to examine the specificity of these automated devices with regard to cells classified as 'reticulocytes' and the effect that this may have on measures of reticulocyte maturity. Our results indicate that the specificity of reticulocyte measurements by both the Sysmex R-1000/-3000 and the Retic-Count system is relatively low. This is due to the presence of leucocytes amongst cells classified as reticulocytes. These leucocytes display intense staining with either dye, leading to an erroneous estimation of RMI (thiazole orange) and high fluorescence count (R-1000/-3000). This error is directly correlated with the leucocyte count. The basis for reticulocyte identification should be improved before automated estimation of reticulocyte maturation can be used in clinical practice.

  1. Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory

    DOE PAGES

    Aab, A.; Abreu, P.; Aglietta, M.; ...

    2017-03-03

    Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), ismore » proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.« less

  2. A Review of Multivariate Distributions for Count Data Derived from the Poisson Distribution.

    PubMed

    Inouye, David; Yang, Eunho; Allen, Genevera; Ravikumar, Pradeep

    2017-01-01

    The Poisson distribution has been widely studied and used for modeling univariate count-valued data. Multivariate generalizations of the Poisson distribution that permit dependencies, however, have been far less popular. Yet, real-world high-dimensional count-valued data found in word counts, genomics, and crime statistics, for example, exhibit rich dependencies, and motivate the need for multivariate distributions that can appropriately model this data. We review multivariate distributions derived from the univariate Poisson, categorizing these models into three main classes: 1) where the marginal distributions are Poisson, 2) where the joint distribution is a mixture of independent multivariate Poisson distributions, and 3) where the node-conditional distributions are derived from the Poisson. We discuss the development of multiple instances of these classes and compare the models in terms of interpretability and theory. Then, we empirically compare multiple models from each class on three real-world datasets that have varying data characteristics from different domains, namely traffic accident data, biological next generation sequencing data, and text data. These empirical experiments develop intuition about the comparative advantages and disadvantages of each class of multivariate distribution that was derived from the Poisson. Finally, we suggest new research directions as explored in the subsequent discussion section.

  3. Application of the microbiological method DEFT/APC to detect minimally processed vegetables treated with gamma radiation

    NASA Astrophysics Data System (ADS)

    Araújo, M. M.; Duarte, R. C.; Silva, P. V.; Marchioni, E.; Villavicencio, A. L. C. H.

    2009-07-01

    Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a 60Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of the two counts gradually increased with dose increment in all samples. It could be suggested that a DEFT/APC difference over 2.0 log would be a criteria to judge if a MPV was treated by irradiation. The DEFT/APC method could be used satisfactorily as a screening method for indicating irradiation processing.

  4. Factor V Leiden is associated with increased sperm count.

    PubMed

    van Mens, T E; Joensen, U N; Bochdanovits, Z; Takizawa, A; Peter, J; Jørgensen, N; Szecsi, P B; Meijers, J C M; Weiler, H; Rajpert-De Meyts, E; Repping, S; Middeldorp, S

    2017-11-01

    Is the thrombophilia mutation factor V Leiden (FVL) associated with an increased total sperm count? Carriers of FVL have a higher total sperm count than non-FVL-carriers, which could not be explained by genetic linkage or by observations in a FVL-mouse model. FVL has a high prevalence in Caucasians despite detrimental health effects. Carriers have been shown to have higher fecundity, which might partly explain this evolutionary paradox. We determined FVL status in two cohorts (Dutch, n = 627; Danish, n = 854) of consecutively included men without known causes for spermatogenic failure, and performed an individual patient data meta-analysis of these two cohorts together with one previously published (Dutch, n = 908) cohort. We explored possible biological underpinnings for the relation between sperm count and FVL, by use of a FVL-mouse model and investigations of genetic linkage. Participants were male partners of subfertile couples (two Dutch cohorts) and young men from the general population (Danish cohort): FVL carrier rate was 4.0%, 4.6% and 7.3%, respectively. There were differences in smoking, abstinence time and age between the cohorts. We corrected for these in the primary analysis, which consisted of a mixed linear effects model, also incorporating unobjectified population differences. In public haplotype data from subjects of European descent, we explored linkage disequilibrium of FVL with all known single nucleotide polymorphisms in a 1.5 MB region around the F5 gene with an R2 cutoff of 0.8. We sequenced exons of four candidate genes hypothesized to be linked to FVL in a subgroup of FVL carriers with extreme sperm count values. The animal studies consisted of never mated 15-18-week-old C57BL/J6 mice heterozygous and homozygous for FVL and wild-type mice. We compared spermatogenesis parameters (normalized internal genitalia weights, epididymis sperm content and sperm motility) between FVL and wild-type mice. Human FVL carriers have a higher total sperm count than non-carriers, with an adjusted mean difference of 31 × 106 (95%CI 0.2-61.7; P = 0.048). Mice with the FVL mutation do not have increased spermatogenesis as compared to wildtype mice. None of the studied polymorphisms was in linkage disequilibrium, either in the public databases or in a subgroup of FVL carriers with extremely high sperm counts. The difference in total sperm count would benefit from confirmation in other cohorts. The finding of higher count in carriers was consistent however, with no heterogeneity between the cohorts. The lack of effect of murine FVL might suggest there is no direct causality. The exploratory efforts on genetic linkage do not rule out that the association is a reflection of FVL co-inheritance with a non-studied causative polymorphism. A high sperm count in FVL-carrying males contributes to understanding the high prevalence of this otherwise disadvantageous mutation. The findings might provide directions for future research on male fertility. No conflicts of interest. Research was conducted with funding from the Netherlands Organisation for Scientific Research (NWO, VIDI innovative research grant 016.126.364 awarded to S. Middeldorp). The Danish cohort was supported by the Innovation Fund Denmark (InnovationsFonden, grant no. 14-2013-4), The Danish Ministry of Health and the Danish Environmental Protection Agency. Not applicable. © The Author 2017. Published by Oxford University Press on behalf of the European Society of Human Reproduction and Embryology. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com

  5. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications

    NASA Astrophysics Data System (ADS)

    Barber, W. C.; Wessel, J. C.; Nygard, E.; Iwanczyk, J. S.

    2015-06-01

    We are developing room temperature compound semiconductor detectors for applications in energy-resolved high-flux single x-ray photon-counting spectral computed tomography (CT), including functional imaging with nanoparticle contrast agents for medical applications and non-destructive testing (NDT) for security applications. Energy-resolved photon-counting can provide reduced patient dose through optimal energy weighting for a particular imaging task in CT, functional contrast enhancement through spectroscopic imaging of metal nanoparticles in CT, and compositional analysis through multiple basis function material decomposition in CT and NDT. These applications produce high input count rates from an x-ray generator delivered to the detector. Therefore, in order to achieve energy-resolved single photon counting in these applications, a high output count rate (OCR) for an energy-dispersive detector must be achieved at the required spatial resolution and across the required dynamic range for the application. The required performance in terms of the OCR, spatial resolution, and dynamic range must be obtained with sufficient field of view (FOV) for the application thus requiring the tiling of pixel arrays and scanning techniques. Room temperature cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) compound semiconductors, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel provided the sensors are designed for rapid signal formation across the x-ray energy ranges of the application at the required energy and spatial resolutions, and at a sufficiently high detective quantum efficiency (DQE). We have developed high-flux energy-resolved photon-counting x-ray imaging array sensors using pixellated CdTe and CdZnTe semiconductors optimized for clinical CT and security NDT. We have also fabricated high-flux ASICs with a two dimensional (2D) array of inputs for readout from the sensors. The sensors are guard ring free and have a 2D array of pixels and can be tiled in 2D while preserving pixel pitch. The 2D ASICs have four energy bins with a linear energy response across sufficient dynamic range for clinical CT and some NDT applications. The ASICs can also be tiled in 2D and are designed to fit within the active area of the sensors. We have measured several important performance parameters including: the output count rate (OCR) in excess of 20 million counts per second per square mm with a minimum loss of counts due to pulse pile-up, an energy resolution of 7 keV full width at half-maximum (FWHM) across the entire dynamic range, and a noise floor about 20 keV. This is achieved by directly interconnecting the ASIC inputs to the pixels of the CdZnTe sensors incurring very little input capacitance to the ASICs. We present measurements of the performance of the CdTe and CdZnTe sensors including the OCR, FWHM energy resolution, noise floor, as well as the temporal stability and uniformity under the rapidly varying high flux expected in CT and NDT applications.

  6. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications

    PubMed Central

    Barber, W. C.; Wessel, J. C.; Nygard, E.; Iwanczyk, J. S.

    2014-01-01

    We are developing room temperature compound semiconductor detectors for applications in energy-resolved high-flux single x-ray photon-counting spectral computed tomography (CT), including functional imaging with nanoparticle contrast agents for medical applications and non destructive testing (NDT) for security applications. Energy-resolved photon-counting can provide reduced patient dose through optimal energy weighting for a particular imaging task in CT, functional contrast enhancement through spectroscopic imaging of metal nanoparticles in CT, and compositional analysis through multiple basis function material decomposition in CT and NDT. These applications produce high input count rates from an x-ray generator delivered to the detector. Therefore, in order to achieve energy-resolved single photon counting in these applications, a high output count rate (OCR) for an energy-dispersive detector must be achieved at the required spatial resolution and across the required dynamic range for the application. The required performance in terms of the OCR, spatial resolution, and dynamic range must be obtained with sufficient field of view (FOV) for the application thus requiring the tiling of pixel arrays and scanning techniques. Room temperature cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) compound semiconductors, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel provided the sensors are designed for rapid signal formation across the x-ray energy ranges of the application at the required energy and spatial resolutions, and at a sufficiently high detective quantum efficiency (DQE). We have developed high-flux energy-resolved photon-counting x-ray imaging array sensors using pixellated CdTe and CdZnTe semiconductors optimized for clinical CT and security NDT. We have also fabricated high-flux ASICs with a two dimensional (2D) array of inputs for readout from the sensors. The sensors are guard ring free and have a 2D array of pixels and can be tiled in 2D while preserving pixel pitch. The 2D ASICs have four energy bins with a linear energy response across sufficient dynamic range for clinical CT and some NDT applications. The ASICs can also be tiled in 2D and are designed to fit within the active area of the sensors. We have measured several important performance parameters including; the output count rate (OCR) in excess of 20 million counts per second per square mm with a minimum loss of counts due to pulse pile-up, an energy resolution of 7 keV full width at half maximum (FWHM) across the entire dynamic range, and a noise floor about 20keV. This is achieved by directly interconnecting the ASIC inputs to the pixels of the CdZnTe sensors incurring very little input capacitance to the ASICs. We present measurements of the performance of the CdTe and CdZnTe sensors including the OCR, FWHM energy resolution, noise floor, as well as the temporal stability and uniformity under the rapidly varying high flux expected in CT and NDT applications. PMID:25937684

  7. Energy dispersive CdTe and CdZnTe detectors for spectral clinical CT and NDT applications.

    PubMed

    Barber, W C; Wessel, J C; Nygard, E; Iwanczyk, J S

    2015-06-01

    We are developing room temperature compound semiconductor detectors for applications in energy-resolved high-flux single x-ray photon-counting spectral computed tomography (CT), including functional imaging with nanoparticle contrast agents for medical applications and non destructive testing (NDT) for security applications. Energy-resolved photon-counting can provide reduced patient dose through optimal energy weighting for a particular imaging task in CT, functional contrast enhancement through spectroscopic imaging of metal nanoparticles in CT, and compositional analysis through multiple basis function material decomposition in CT and NDT. These applications produce high input count rates from an x-ray generator delivered to the detector. Therefore, in order to achieve energy-resolved single photon counting in these applications, a high output count rate (OCR) for an energy-dispersive detector must be achieved at the required spatial resolution and across the required dynamic range for the application. The required performance in terms of the OCR, spatial resolution, and dynamic range must be obtained with sufficient field of view (FOV) for the application thus requiring the tiling of pixel arrays and scanning techniques. Room temperature cadmium telluride (CdTe) and cadmium zinc telluride (CdZnTe) compound semiconductors, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel provided the sensors are designed for rapid signal formation across the x-ray energy ranges of the application at the required energy and spatial resolutions, and at a sufficiently high detective quantum efficiency (DQE). We have developed high-flux energy-resolved photon-counting x-ray imaging array sensors using pixellated CdTe and CdZnTe semiconductors optimized for clinical CT and security NDT. We have also fabricated high-flux ASICs with a two dimensional (2D) array of inputs for readout from the sensors. The sensors are guard ring free and have a 2D array of pixels and can be tiled in 2D while preserving pixel pitch. The 2D ASICs have four energy bins with a linear energy response across sufficient dynamic range for clinical CT and some NDT applications. The ASICs can also be tiled in 2D and are designed to fit within the active area of the sensors. We have measured several important performance parameters including; the output count rate (OCR) in excess of 20 million counts per second per square mm with a minimum loss of counts due to pulse pile-up, an energy resolution of 7 keV full width at half maximum (FWHM) across the entire dynamic range, and a noise floor about 20keV. This is achieved by directly interconnecting the ASIC inputs to the pixels of the CdZnTe sensors incurring very little input capacitance to the ASICs. We present measurements of the performance of the CdTe and CdZnTe sensors including the OCR, FWHM energy resolution, noise floor, as well as the temporal stability and uniformity under the rapidly varying high flux expected in CT and NDT applications.

  8. Directions in Rehabilitation Counseling. Volume 9.

    ERIC Educational Resources Information Center

    Directions in Rehabilitation Counseling, 1998

    1998-01-01

    Rehabilitation counselors must stay apprised of numerous issues in their field. To help them remain current, this volume features 12 lessons which can count as continuing education credits. Lesson 1 explores issues surrounding Latino clients, focusing on cultural considerations, ethnic identity, and the counselor-client relationship. Sexuality…

  9. On Models for Binomial Data with Random Numbers of Trials

    PubMed Central

    Comulada, W. Scott; Weiss, Robert E.

    2010-01-01

    Summary A binomial outcome is a count s of the number of successes out of the total number of independent trials n = s + f, where f is a count of the failures. The n are random variables not fixed by design in many studies. Joint modeling of (s, f) can provide additional insight into the science and into the probability π of success that cannot be directly incorporated by the logistic regression model. Observations where n = 0 are excluded from the binomial analysis yet may be important to understanding how π is influenced by covariates. Correlation between s and f may exist and be of direct interest. We propose Bayesian multivariate Poisson models for the bivariate response (s, f), correlated through random effects. We extend our models to the analysis of longitudinal and multivariate longitudinal binomial outcomes. Our methodology was motivated by two disparate examples, one from teratology and one from an HIV tertiary intervention study. PMID:17688514

  10. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vedantham, Srinivasan; Shrestha, Suman; Karellas, Andrew, E-mail: andrew.karellas@umassmed.edu

    Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixelmore » pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.« less

  11. Dating Tectonic Activity on Mercury’s Large-Scale Lobate-Scarp Thrust Faults

    NASA Astrophysics Data System (ADS)

    Barlow, Nadine G.; E Banks, Maria

    2017-10-01

    Mercury’s widespread large-scale lobate-scarp thrust faults reveal that the planet’s tectonic history has been dominated by global contraction, primarily due to cooling of its interior. Constraining the timing and duration of this contraction provides key insight into Mercury’s thermal and geologic evolution. We combine two techniques to enhance the statistical validity of size-frequency distribution crater analyses and constrain timing of the 1) earliest and 2) most recent detectable activity on several of Mercury’s largest lobate-scarp thrust faults. We use the sizes of craters directly transected by or superposed on the edge of the scarp face to define a count area around the scarp, a method we call the Modified Buffered Crater Counting Technique (MBCCT). We developed the MBCCT to avoid the issue of a near-zero scarp width since feature widths are included in area calculations of the commonly used Buffered Crater Counting Technique (BCCT). Since only craters directly intersecting the scarp face edge conclusively show evidence of crosscutting relations, we increase the number of craters in our analysis (and reduce uncertainties) by using the morphologic degradation state (i.e. relative age) of these intersecting craters to classify other similarly degraded craters within the count area (i.e., those with the same relative age) as superposing or transected. The resulting crater counts are divided into two categories: transected craters constrain the earliest possible activity and superposed craters constrain the most recent detectable activity. Absolute ages are computed for each population using the Marchi et al. [2009] model production function. A test of the Blossom lobate scarp indicates the MBCCT gives statistically equivalent results to the BCCT. We find that all scarps in this study crosscut surfaces Tolstojan or older in age (>~3.7 Ga). The most recent detectable activity along lobate-scarp thrust faults ranges from Calorian to Kuiperian (~3.7 Ga to present). Our results complement previous relative-age studies with absolute ages and indicate global contraction continued over the last ~3-4 Gyr. At least some thrust fault activity occurred on Mercury in relatively recent times (<280 Ma).

  12. A generalised random encounter model for estimating animal density with remote sensor data.

    PubMed

    Lucas, Tim C D; Moorcroft, Elizabeth A; Freeman, Robin; Rowcliffe, J Marcus; Jones, Kate E

    2015-05-01

    Wildlife monitoring technology is advancing rapidly and the use of remote sensors such as camera traps and acoustic detectors is becoming common in both the terrestrial and marine environments. Current methods to estimate abundance or density require individual recognition of animals or knowing the distance of the animal from the sensor, which is often difficult. A method without these requirements, the random encounter model (REM), has been successfully applied to estimate animal densities from count data generated from camera traps. However, count data from acoustic detectors do not fit the assumptions of the REM due to the directionality of animal signals.We developed a generalised REM (gREM), to estimate absolute animal density from count data from both camera traps and acoustic detectors. We derived the gREM for different combinations of sensor detection widths and animal signal widths (a measure of directionality). We tested the accuracy and precision of this model using simulations of different combinations of sensor detection widths and animal signal widths, number of captures and models of animal movement.We find that the gREM produces accurate estimates of absolute animal density for all combinations of sensor detection widths and animal signal widths. However, larger sensor detection and animal signal widths were found to be more precise. While the model is accurate for all capture efforts tested, the precision of the estimate increases with the number of captures. We found no effect of different animal movement models on the accuracy and precision of the gREM.We conclude that the gREM provides an effective method to estimate absolute animal densities from remote sensor count data over a range of sensor and animal signal widths. The gREM is applicable for count data obtained in both marine and terrestrial environments, visually or acoustically (e.g. big cats, sharks, birds, echolocating bats and cetaceans). As sensors such as camera traps and acoustic detectors become more ubiquitous, the gREM will be increasingly useful for monitoring unmarked animal populations across broad spatial, temporal and taxonomic scales.

  13. Bacterial adhesion on direct and indirect dental restorative composite resins: An in vitro study on a natural biofilm.

    PubMed

    Derchi, Giacomo; Vano, Michele; Barone, Antonio; Covani, Ugo; Diaspro, Alberto; Salerno, Marco

    2017-05-01

    Both direct and indirect techniques are used for dental restorations. Which technique should be preferred or whether they are equivalent with respect to bacterial adhesion is unclear. The purpose of this in vitro study was to determine the affinity of bacterial biofilm to dental restorative composite resins placed directly and indirectly. Five direct composite resins for restorations (Venus Diamond, Adonis, Optifil, Enamel Plus HRi, Clearfil Majesty Esthetic) and 3 indirect composite resins (Gradia, Estenia, Signum) were selected. The materials were incubated in unstimulated whole saliva for 1 day. The biofilms grown were collected and their bacterial cells counted. In parallel, the composite resin surface morphology was analyzed with atomic force microscopy. Both bacterial cell count and surface topography parameters were subjected to statistical analysis (α=.05). Indirect composite resins showed significantly lower levels than direct composite resins for bacterial cell adhesion, (P<.001). No significant differences were observed within the direct composite resins (P>.05). However, within the indirect composite resins a significantly lower level was found for Gradia than Estenia or Signum (P<.01). A partial correlation was observed between composite resin roughness and bacterial adhesion when the second and particularly the third-order statistical moments of the composite resin height distributions were considered. Indirect dental restorative composite resins were found to be less prone to biofilm adhesion than direct composite resins. A correlation of bacterial adhesion to surface morphology exists that is described by kurtosis; thus, advanced data analysis is required to discover possible insights into the biologic effects of morphology. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  14. Cardiac-gated parametric images from 82 Rb PET from dynamic frames and direct 4D reconstruction.

    PubMed

    Germino, Mary; Carson, Richard E

    2018-02-01

    Cardiac perfusion PET data can be reconstructed as a dynamic sequence and kinetic modeling performed to quantify myocardial blood flow, or reconstructed as static gated images to quantify function. Parametric images from dynamic PET are conventionally not gated, to allow use of all events with lower noise. An alternative method for dynamic PET is to incorporate the kinetic model into the reconstruction algorithm itself, bypassing the generation of a time series of emission images and directly producing parametric images. So-called "direct reconstruction" can produce parametric images with lower noise than the conventional method because the noise distribution is more easily modeled in projection space than in image space. In this work, we develop direct reconstruction of cardiac-gated parametric images for 82 Rb PET with an extension of the Parametric Motion compensation OSEM List mode Algorithm for Resolution-recovery reconstruction for the one tissue model (PMOLAR-1T). PMOLAR-1T was extended to accommodate model terms to account for spillover from the left and right ventricles into the myocardium. The algorithm was evaluated on a 4D simulated 82 Rb dataset, including a perfusion defect, as well as a human 82 Rb list mode acquisition. The simulated list mode was subsampled into replicates, each with counts comparable to one gate of a gated acquisition. Parametric images were produced by the indirect (separate reconstructions and modeling) and direct methods for each of eight low-count and eight normal-count replicates of the simulated data, and each of eight cardiac gates for the human data. For the direct method, two initialization schemes were tested: uniform initialization, and initialization with the filtered iteration 1 result of the indirect method. For the human dataset, event-by-event respiratory motion compensation was included. The indirect and direct methods were compared for the simulated dataset in terms of bias and coefficient of variation as a function of iteration. Convergence of direct reconstruction was slow with uniform initialization; lower bias was achieved in fewer iterations by initializing with the filtered indirect iteration 1 images. For most parameters and regions evaluated, the direct method achieved the same or lower absolute bias at matched iteration as the indirect method, with 23%-65% lower noise. Additionally, the direct method gave better contrast between the perfusion defect and surrounding normal tissue than the indirect method. Gated parametric images from the human dataset had comparable relative performance of indirect and direct, in terms of mean parameter values per iteration. Changes in myocardial wall thickness and blood pool size across gates were readily visible in the gated parametric images, with higher contrast between myocardium and left ventricle blood pool in parametric images than gated SUV images. Direct reconstruction can produce parametric images with less noise than the indirect method, opening the potential utility of gated parametric imaging for perfusion PET. © 2017 American Association of Physicists in Medicine.

  15. Simplified fast neutron dosimeter

    DOEpatents

    Sohrabi, Mehdi

    1979-01-01

    Direct fast-neutron-induced recoil and alpha particle tracks in polycarbonate films may be enlarged for direct visual observation and automated counting procedures employing electrochemical etching techniques. Electrochemical etching is, for example, carried out in a 28% KOH solution at room temperature by applying a 2000 V peak-to-peak voltage at 1 kHz frequency. Such recoil particle amplification can be used for the detection of wide neutron dose ranges from 1 mrad. to 1000 rads. or higher, if desired.

  16. 29 CFR 785.18 - Rest.

    Code of Federal Regulations, 2011 CFR

    2011-07-01

    ... INTERPRETATION NOT DIRECTLY RELATED TO REGULATIONS HOURS WORKED Application of Principles Rest and Meal Periods... industry. They promote the efficiency of the employee and are customarily paid for as working time. They must be counted as hours worked. Compensable time of rest periods may not be offset against other...

  17. 29 CFR 785.18 - Rest.

    Code of Federal Regulations, 2010 CFR

    2010-07-01

    ... INTERPRETATION NOT DIRECTLY RELATED TO REGULATIONS HOURS WORKED Application of Principles Rest and Meal Periods... industry. They promote the efficiency of the employee and are customarily paid for as working time. They must be counted as hours worked. Compensable time of rest periods may not be offset against other...

  18. How do I convert the numbers stored in the files to physical quantities?

    Atmospheric Science Data Center

    2014-12-08

    At Level 1A, the 14 most significant bits (MSB) directly represent the raw digital count from the camera's Charge-Coupled Device (CCD). The 2 least significant bits (LSB) of the 16-bit data values are data quality indicators (DQI). A...

  19. Why Girls Don't Count.

    ERIC Educational Resources Information Center

    Grasset, Nike

    1991-01-01

    Examines the texts of 12 historians with access to educational directives produced by the Victorian Department of Education since the 1850s to determine the effects of curricular requirements on female enrollment in mathematics courses. Argues that girls were prohibited from taking arithmetic and mathematics because of other curricular…

  20. Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme

    NASA Technical Reports Server (NTRS)

    Van Amerom, Friso H.; Short, Tim; Brinckerhoff, William; Mahaffy, Paul; Kleyner, Igor; Cotter, Robert J.; Pinnick, Veronica; Hoffman, Lars; Danell, Ryan M.; Lyness, Eric I.

    2011-01-01

    The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250

  1. Evaluation of seven aquatic sampling methods for amphibians and other aquatic fauna

    USGS Publications Warehouse

    Gunzburger, M.S.

    2007-01-01

    To design effective and efficient research and monitoring programs researchers must have a thorough understanding of the capabilities and limitations of their sampling methods. Few direct comparative studies exist for aquatic sampling methods for amphibians. The objective of this study was to simultaneously employ seven aquatic sampling methods in 10 wetlands to compare amphibian species richness and number of individuals detected with each method. Four sampling methods allowed counts of individuals (metal dipnet, D-frame dipnet, box trap, crayfish trap), whereas the other three methods allowed detection of species (visual encounter, aural, and froglogger). Amphibian species richness was greatest with froglogger, box trap, and aural samples. For anuran species, the sampling methods by which each life stage was detected was related to relative length of larval and breeding periods and tadpole size. Detection probability of amphibians varied across sampling methods. Box trap sampling resulted in the most precise amphibian count, but the precision of all four count-based methods was low (coefficient of variation > 145 for all methods). The efficacy of the four count sampling methods at sampling fish and aquatic invertebrates was also analyzed because these predatory taxa are known to be important predictors of amphibian habitat distribution. Species richness and counts were similar for fish with the four methods, whereas invertebrate species richness and counts were greatest in box traps. An effective wetland amphibian monitoring program in the southeastern United States should include multiple sampling methods to obtain the most accurate assessment of species community composition at each site. The combined use of frogloggers, crayfish traps, and dipnets may be the most efficient and effective amphibian monitoring protocol. ?? 2007 Brill Academic Publishers.

  2. Physical activity, white blood cell count, and lung cancer risk in a prospective cohort study

    PubMed Central

    Sprague, Brian L.; Trentham-Dietz, Amy; Klein, Barbara E.K.; Klein, Ronald; Cruickshanks, Karen J.; Lee, Kristine E.; Hampton, John M.

    2009-01-01

    Previous studies have suggested that physical activity may lower lung cancer risk. The association of physical activity with reduced chronic inflammation provides a potential mechanism, yet few studies have directly related inflammatory markers to cancer incidence. The relation between physical activity, inflammation, and lung cancer risk was evaluated in a prospective cohort of 4,831 subjects, 43–86 years of age, in Beaver Dam, Wisconsin. A total physical activity index was created by summing kilocalories per week from sweat-inducing physical activities, city blocks walked, and flights of stairs climbed. Two inflammatory markers, white blood cell count and serum albumin, were measured at the baseline examination. During an average of 12.8 years of follow-up, 134 incident cases of lung cancer were diagnosed. After multivariable adjustment, participants in the highest tertile of total physical activity index had a 45% reduction in lung cancer risk compared to those in the lowest tertile (OR=0.55; 95% CI: 0.35–0.86). Participants with white blood cell counts in the upper tertile (≥8×103/μL) were 2.81 (95% CI: 1.58–5.01) times as likely to develop lung cancer as those with counts in the lowest tertile (<6.4×103/μL). Serum albumin was not related to lung cancer risk. There was no evidence that inflammation mediated the association between physical activity and lung cancer risk, as the physical activity risk estimates were essentially unchanged after adjustment for white blood cell count. While the potential for residual confounding by smoking could not be eliminated, these data suggest that physical activity and white blood cell count are independent risk factors for lung cancer. PMID:18843014

  3. Design Study of an Incinerator Ash Conveyor Counting System - 13323

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Jaederstroem, Henrik; Bronson, Frazier

    A design study has been performed for a system that should measure the Cs-137 activity in ash from an incinerator. Radioactive ash, expected to consist of both Cs-134 and Cs-137, will be transported on a conveyor belt at 0.1 m/s. The objective of the counting system is to determine the Cs-137 activity and direct the ash to the correct stream after a diverter. The decision levels are ranging from 8000 to 400000 Bq/kg and the decision error should be as low as possible. The decision error depends on the total measurement uncertainty which depends on the counting statistics and themore » uncertainty in the efficiency of the geometry. For the low activity decision it is necessary to know the efficiency to be able to determine if the signal from the Cs-137 is above the minimum detectable activity and that it generates enough counts to reach the desired precision. For the higher activity decision the uncertainty of the efficiency needs to be understood to minimize decision errors. The total efficiency of the detector is needed to be able to determine if the detector will be able operate at the count rate at the highest expected activity. The design study that is presented in this paper describes how the objectives of the monitoring systems were obtained, the choice of detector was made and how ISOCS (In Situ Object Counting System) mathematical modeling was used to calculate the efficiency. The ISOCS uncertainty estimator (IUE) was used to determine which parameters of the ash was important to know accurately in order to minimize the uncertainty of the efficiency. The examined parameters include the height of the ash on the conveyor belt, the matrix composition and density and relative efficiency of the detector. (authors)« less

  4. High-precision half-life measurements for the superallowed Fermi β+ emitter 14O

    NASA Astrophysics Data System (ADS)

    Laffoley, A. T.; Svensson, C. E.; Andreoiu, C.; Austin, R. A. E.; Ball, G. C.; Blank, B.; Bouzomita, H.; Cross, D. S.; Diaz Varela, A.; Dunlop, R.; Finlay, P.; Garnsworthy, A. B.; Garrett, P. E.; Giovinazzo, J.; Grinyer, G. F.; Hackman, G.; Hadinia, B.; Jamieson, D. S.; Ketelhut, S.; Leach, K. G.; Leslie, J. R.; Tardiff, E.; Thomas, J. C.; Unsworth, C.

    2013-07-01

    The half-life of the superallowed Fermi β+ emitter 14O has been determined via simultaneous direct β and γ counting experiments at TRIUMF's Isotope Separator and Accelerator (ISAC) facility. A γ-ray counting measurement was performed by detecting the 2312.6-keV γ rays emitted from an excited state of the daughter 14N following the implantation of samples at the center of the 8π γ-ray spectrometer, a spherical array of 20 high-purity germanium (HPGe) detectors. A simultaneous β counting experiment was performed using a fast plastic scintillator positioned behind the implantation site with a solid angle coverage of ˜20%. The results, T1/2(β)=70.610±0.030s and T1/2(γ)=70.632±0.094s, form a consistent set and, together with eight previous measurements, establish a new average for the 14O half-life of T1/2=70.619±0.011s with a reduced χ2 of 0.99.

  5. Point-by-point compositional analysis for atom probe tomography.

    PubMed

    Stephenson, Leigh T; Ceguerra, Anna V; Li, Tong; Rojhirunsakool, Tanaporn; Nag, Soumya; Banerjee, Rajarshi; Cairney, Julie M; Ringer, Simon P

    2014-01-01

    This new alternate approach to data processing for analyses that traditionally employed grid-based counting methods is necessary because it removes a user-imposed coordinate system that not only limits an analysis but also may introduce errors. We have modified the widely used "binomial" analysis for APT data by replacing grid-based counting with coordinate-independent nearest neighbour identification, improving the measurements and the statistics obtained, allowing quantitative analysis of smaller datasets, and datasets from non-dilute solid solutions. It also allows better visualisation of compositional fluctuations in the data. Our modifications include:.•using spherical k-atom blocks identified by each detected atom's first k nearest neighbours.•3D data visualisation of block composition and nearest neighbour anisotropy.•using z-statistics to directly compare experimental and expected composition curves. Similar modifications may be made to other grid-based counting analyses (contingency table, Langer-Bar-on-Miller, sinusoidal model) and could be instrumental in developing novel data visualisation options.

  6. The use of multiple indices of physiological activity to access viability in chlorine disinfected Escherichia coli O157:H7

    NASA Technical Reports Server (NTRS)

    Lisle, J. T.; Pyle, B. H.; McFeters, G. A.

    1999-01-01

    A suite of fluorescent intracellular stains and probes was used, in conjunction with viable plate counts, to assess the effect of chlorine disinfection on membrane potential (rhodamine 123; Rh123 and bis-(1,3-dibutylbarbituric acid) trimethine oxonol; DiBAC4(3)), membrane integrity (LIVE/DEAD BacLight kit), respiratory activity (5-cyano-2,3-ditolyl tetrazolium chloride; CTC) and substrate responsiveness (direct viable counts; DVC) in the commensal pathogen Escherichia coli O157:H7. After a 5 min exposure to the disinfectant, physiological indices were affected in the following order: viable plate counts > substrate responsiveness > membrane potential > respiratory activity > membrane integrity. In situ assessment of physiological activity by examining multiple targets, as demonstrated in this study, permits a more comprehensive determination of the site and extent of injury in bacterial cells following sublethal disinfection with chlorine. This approach to assessing altered bacterial physiology has application in various fields where detection of stressed bacteria is of interest.

  7. Using Eulerian video magnification to enhance detection of fasciculations in people with amyotrophic lateral sclerosis.

    PubMed

    Van Hillegondsberg, Ludo; Carr, Jonathan; Brey, Naeem; Henning, Franclo

    2017-12-01

    This study seeks to determine whether the use of Eulerian video magnification (EVM) increases the detection of muscle fasciculations in people with amyotrophic lateral sclerosis (PALS) compared with direct clinical observation (DCO). Thirty-second-long video recordings were taken of 9 body regions of 7 PALS and 7 controls, and fasciculations were counted by DCO during the same 30-s period. The video recordings were then motion magnified and reviewed by 2 independent assessors. In PALS, median fasciculation count per body region was 1 by DCO (range 0-10) and 3 in the EVM recordings (range 0-15; P < 0.0001). EVM revealed more fasciculations than DCO in 61% of recordings. In controls, median fasciculation count was 0 for both DCO and EVM. Compared with DCO, EVM significantly increased the detection of fasciculations in body regions of PALS. When it is used to supplement clinical examination, EVM has the potential to facilitate the diagnosis of ALS. Muscle Nerve 56: 1063-1067, 2017. © 2017 Wiley Periodicals, Inc.

  8. Diffusion processes in tumors: A nuclear medicine approach

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Amaya, Helman, E-mail: haamayae@unal.edu.co

    The number of counts used in nuclear medicine imaging techniques, only provides physical information about the desintegration of the nucleus present in the the radiotracer molecules that were uptaken in a particular anatomical region, but that information is not a real metabolic information. For this reason a mathematical method was used to find a correlation between number of counts and {sup 18}F-FDG mass concentration. This correlation allows a better interpretation of the results obtained in the study of diffusive processes in an agar phantom, and based on it, an image from the PETCETIX DICOM sample image set from OsiriX-viewer softwaremore » was processed. PET-CT gradient magnitude and Laplacian images could show direct information on diffusive processes for radiopharmaceuticals that enter into the cells by simple diffusion. In the case of the radiopharmaceutical {sup 18}F-FDG is necessary to include pharmacokinetic models, to make a correct interpretation of the gradient magnitude and Laplacian of counts images.« less

  9. Liver function in workers exposed of the cosmetics industry.

    PubMed

    Casale, T; Caciari, T; Rosati, M V; Biagi, M; De Sio, S; Andreozzi, G; Schifano, M P; Capozzella, A; Pimpinella, B; Tomei, G; Tomei, F

    2013-01-01

    The purpose of this study is to assess whether occupational exposure to substances used in the cosmetic factories may cause effects on the liver and blood counts in exposed workers. The study included 48 exposed workers and 86 unexposed controls. All workers included in the study underwent blood count, white blood count, total, direct and indirect bilirubin, transaminases, alkaline phosphatase and cholinesterase. The differences between the means and frequencies were compared using the Student's t-test and chi-square test with Yates correction and were considered significant when the p value was <0.05. The analysis of the results shows that 35.4% of workers in the cosmetics industry had liver test values above the range. We noted a statistically significant higher prevalence of GPT (p <0.05) and total bilirubin (p <0.05) in the workers of the cosmetics industry compared with the control group. The results obtained suggest that occupational exposure to low doses of substances used in the cosmetic industry is able to influence some liver parameters in occupationally exposed workers.

  10. Use of simulation tools to illustrate the effect of data management practices for low and negative plate counts on the estimated parameters of microbial reduction models.

    PubMed

    Garcés-Vega, Francisco; Marks, Bradley P

    2014-08-01

    In the last 20 years, the use of microbial reduction models has expanded significantly, including inactivation (linear and nonlinear), survival, and transfer models. However, a major constraint for model development is the impossibility to directly quantify the number of viable microorganisms below the limit of detection (LOD) for a given study. Different approaches have been used to manage this challenge, including ignoring negative plate counts, using statistical estimations, or applying data transformations. Our objective was to illustrate and quantify the effect of negative plate count data management approaches on parameter estimation for microbial reduction models. Because it is impossible to obtain accurate plate counts below the LOD, we performed simulated experiments to generate synthetic data for both log-linear and Weibull-type microbial reductions. We then applied five different, previously reported data management practices and fit log-linear and Weibull models to the resulting data. The results indicated a significant effect (α = 0.05) of the data management practices on the estimated model parameters and performance indicators. For example, when the negative plate counts were replaced by the LOD for log-linear data sets, the slope of the subsequent log-linear model was, on average, 22% smaller than for the original data, the resulting model underpredicted lethality by up to 2.0 log, and the Weibull model was erroneously selected as the most likely correct model for those data. The results demonstrate that it is important to explicitly report LODs and related data management protocols, which can significantly affect model results, interpretation, and utility. Ultimately, we recommend using only the positive plate counts to estimate model parameters for microbial reduction curves and avoiding any data value substitutions or transformations when managing negative plate counts to yield the most accurate model parameters.

  11. Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril

    High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less

  12. Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

    DOE PAGES

    Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; ...

    2017-10-09

    High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less

  13. Estimation of low-level neutron dose-equivalent rate by using extrapolation method for a curie level Am-Be neutron source.

    PubMed

    Li, Gang; Xu, Jiayun; Zhang, Jie

    2015-01-01

    Neutron radiation protection is an important research area because of the strong radiation biological effect of neutron field. The radiation dose of neutron is closely related to the neutron energy, and the connected relationship is a complex function of energy. For the low-level neutron radiation field (e.g. the Am-Be source), the commonly used commercial neutron dosimeter cannot always reflect the low-level dose rate, which is restricted by its own sensitivity limit and measuring range. In this paper, the intensity distribution of neutron field caused by a curie level Am-Be neutron source was investigated by measuring the count rates obtained through a 3 He proportional counter at different locations around the source. The results indicate that the count rates outside of the source room are negligible compared with the count rates measured in the source room. In the source room, 3 He proportional counter and neutron dosimeter were used to measure the count rates and dose rates respectively at different distances to the source. The results indicate that both the count rates and dose rates decrease exponentially with the increasing distance, and the dose rates measured by a commercial dosimeter are in good agreement with the results calculated by the Geant4 simulation within the inherent errors recommended by ICRP and IEC. Further studies presented in this paper indicate that the low-level neutron dose equivalent rates in the source room increase exponentially with the increasing low-energy neutron count rates when the source is lifted from the shield with different radiation intensities. Based on this relationship as well as the count rates measured at larger distance to the source, the dose rates can be calculated approximately by the extrapolation method. This principle can be used to estimate the low level neutron dose values in the source room which cannot be measured directly by a commercial dosimeter. Copyright © 2014 Elsevier Ltd. All rights reserved.

  14. Microbiological assessment of house and imported bottled water by comparison of bacterial endotoxin concentration, heterotrophic plate count, and fecal coliform count.

    PubMed

    Reyes, Mayra I; Pérez, Cynthia M; Negrón, Edna L

    2008-03-01

    Consumers increasingly use bottled water and home water treatment systems to avoid direct tap water. According to the International Bottled Water Association (IBWA), an industry trade group, 5 billion gallons of bottled water were consumed by North Americans in 2001. The principal aim of this study was to assess the microbial quality of in-house and imported bottled water for human consumption, by measurement and comparison of the concentration of bacterial endotoxin and standard cultivable methods of indicator microorganisms, specifically, heterotrophic and fecal coliform plate counts. A total of 21 brands of commercial bottled water, consisting of 10 imported and 11 in-house brands, selected at random from 96 brands that are consumed in Puerto Rico, were tested at three different time intervals. The Standard Limulus Amebocyte Lysate test, gel clot method, was used to measure the endotoxin concentrations. The minimum endotoxin concentration in 63 water samples was less than 0.0625 EU/mL, while the maximum was 32 EU/mL. The minimum bacterial count showed no growth, while the maximum was 7,500 CFU/mL. Bacterial isolates like P. fluorescens, Corynebacterium sp. J-K, S. paucimobilis, P. versicularis, A. baumannii, P. chlororaphis, F. indologenes, A. faecalis and P. cepacia were identified. Repeated measures analysis of variance demonstrated that endotoxin concentration did not change over time, while there was a statistically significant (p < 0.05) decrease in bacterial count over time. In addition, multiple linear regression analysis demonstrated that a unit change in the concentration of endotoxin across time was associated with a significant (p < 0.05) reduction in the bacteriological cell count. This analysis evidenced a significant time effect in the average log bacteriological cell count. Although bacterial growth was not detected in some water samples, endotoxin was present. Measurement of Gram-negative bacterial endotoxins is one of the methods that have been suggested as a rapid way of determining bacteriological water quality.

  15. Delayed gamma-ray spectroscopy with lanthanum bromide detector for non-destructive assay of nuclear material

    NASA Astrophysics Data System (ADS)

    Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; Hunt, Alan W.; Ludewigt, Bernhard

    2018-01-01

    High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ∼6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2" (length) × 2" (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ∼3 Mcps. An experimental methodology was developed that uses the average current from the PMT's anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ∼3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.

  16. Onsite-effects of dual-hemisphere versus conventional single-hemisphere transcranial direct current stimulation: A functional MRI study.

    PubMed

    Kwon, Yong Hyun; Jang, Sung Ho

    2012-08-25

    We performed functional MRI examinations in six right-handed healthy subjects. During functional MRI scanning, transcranial direct current stimulation was delivered with the anode over the right primary sensorimotor cortex and the cathode over the left primary sensorimotor cortex using dual-hemispheric transcranial direct current stimulation. This was compared to a cathode over the left supraorbital area using conventional single-hemispheric transcranial direct current stimulation. Voxel counts and blood oxygenation level-dependent signal intensities in the right primary sensorimotor cortex regions were estimated and compared between the two transcranial direct current stimulation conditions. Our results showed that dual-hemispheric transcranial direct current stimulation induced greater cortical activities than single-hemispheric transcranial direct current stimulation. These findings suggest that dual-hemispheric transcranial direct current stimulation may provide more effective cortical stimulation than single-hemispheric transcranial direct current stimulation.

  17. Onsite-effects of dual-hemisphere versus conventional single-hemisphere transcranial direct current stimulation

    PubMed Central

    Kwon, Yong Hyun; Jang, Sung Ho

    2012-01-01

    We performed functional MRI examinations in six right-handed healthy subjects. During functional MRI scanning, transcranial direct current stimulation was delivered with the anode over the right primary sensorimotor cortex and the cathode over the left primary sensorimotor cortex using dual-hemispheric transcranial direct current stimulation. This was compared to a cathode over the left supraorbital area using conventional single-hemispheric transcranial direct current stimulation. Voxel counts and blood oxygenation level-dependent signal intensities in the right primary sensorimotor cortex regions were estimated and compared between the two transcranial direct current stimulation conditions. Our results showed that dual-hemispheric transcranial direct current stimulation induced greater cortical activities than single-hemispheric transcranial direct current stimulation. These findings suggest that dual-hemispheric transcranial direct current stimulation may provide more effective cortical stimulation than single-hemispheric transcranial direct current stimulation. PMID:25624815

  18. Differential white cell count by centrifugal microfluidics.

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.

    We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generationmore » of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.« less

  19. Big spleens and hypersplenism: fix it or forget it?

    PubMed

    Boyer, Thomas D; Habib, Shahid

    2015-05-01

    Hypersplenism is a common manifestation of portal hypertension in the cirrhotic. More than half of cirrhotics will have low platelet counts, but neutropenia is much less common. Despite being common in the cirrhotic population, the presence of hypersplenism is of little clinical consequence. The presence of hypersplenism suggests more advanced liver disease and an increase in risk of complications, but there is no data showing that correcting the hypersplenism improves patient survival. In most series, the most common indications for treating the hypersplenism is to increase platelet and white blood cell counts to allow for use of drugs that suppress the bone marrow such as interferon alpha and chemotherapeutic agents. There are several approaches used to treat hypersplenism. Portosystemic shunts are of questionable benefit. Splenectomy, either open or laparoscopically, is the most effective but is associated with a significant risk of portal vein thrombosis. Partial splenic artery embolization and radiofrequency ablation are effective methods for treating hypersplenism, but counts tend to fall back to baseline long-term. Pharmacological agents are also effective in increasing platelet counts. Development of direct acting antivirals against hepatitis C will eliminate the most common indication for treatment. We lack controlled trials designed to determine if treating the hypersplenism has benefits other than raising the platelet and white blood cell counts. In the absence of such studies, hypersplenism in most patients should be considered a laboratory abnormality and not treated, in other words forget it. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  20. Countability of Planck Boxes in Quantum Branching Models

    NASA Astrophysics Data System (ADS)

    Berezin, Alexander A.

    2002-04-01

    Two popular paradigms of cosmological quantum branching are Many World (MW) model of parallel universes (Everett, Deutsch) and inflationary quantum foam (IQF) model (Guth, Linde). Taking Planck L,T units as physically smallest, our Big Bang miniverse with size 10E28 cm and duration 10E18 sec has some 10E244 (N) elementary 4D Planck Boxes (PB) in its entire spacetime history. Using combinatorics, N! (about 10E10E247) is upper estimate for number of all possible 4D states, i.e. scale of "eternal return" (ER; Nietzsche, Eliade) for such miniverses. To count all states in full Megaverse (all up and down branches of infinite tree of all MW and/or IQF miniverses) we recall that all countable infinities have same (aleph-naught) cardinality (Cantor). Using Godel-type numbering, count PB in our miniverse by primes. This uses first N primes. Both MW and IQF models presume splitting of miniverses as springing (potentially) from each PB, making each PB infinitely rich, inexhaustible and unique. Next branching level is counted by integers p1Ep2, third level by p1Ep2Ep3 integers, etc, ad infinitum. To count in up and down directions from "our" miniverse, different branching subsets of powers of primes can be used at all levels of tower exponentiation. Thus, all PB in all infinitude of MW and/or IQF branches can be uniquely counted by never repeating integers (tower exponents of primes), offering escape from grim ER scenarios.

  1. Exact Local Correlations and Full Counting Statistics for Arbitrary States of the One-Dimensional Interacting Bose Gas

    NASA Astrophysics Data System (ADS)

    Bastianello, Alvise; Piroli, Lorenzo; Calabrese, Pasquale

    2018-05-01

    We derive exact analytic expressions for the n -body local correlations in the one-dimensional Bose gas with contact repulsive interactions (Lieb-Liniger model) in the thermodynamic limit. Our results are valid for arbitrary states of the model, including ground and thermal states, stationary states after a quantum quench, and nonequilibrium steady states arising in transport settings. Calculations for these states are explicitly presented and physical consequences are critically discussed. We also show that the n -body local correlations are directly related to the full counting statistics for the particle-number fluctuations in a short interval, for which we provide an explicit analytic result.

  2. On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

    DOE PAGES

    Godfrey, B.; Anderson, T.; Breedon, E.; ...

    2018-03-26

    Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

  3. On the evaluation of silicon photomultipliers for use as photosensors in liquid xenon detectors

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Godfrey, B.; Anderson, T.; Breedon, E.

    Silicon photomultipliers (SiPMs) are potential solid-state alternatives to traditional photomultiplier tubes (PMTs) for single-photon detection. In this paper, we report on evaluating SensL MicroFC-10035-SMT SiPMs for their suitability as PMT alternatives. The devices were successfully operated in a liquid-xenon detector, which demonstrates that SiPMs can be used in noble element time projection chambers as photosensors. The devices were also cooled down to 170 K to observe dark count dependence on temperature. No dependencies on the direction of an applied 3.2 kV/cm electric field were observed with respect to dark-count rate, gain, or photon detection efficiency.

  4. Measurement system

    NASA Technical Reports Server (NTRS)

    Turner, J. W. (Inventor)

    1973-01-01

    A measurement system is described for providing an indication of a varying physical quantity represented by or converted to a variable frequency signal. Timing pulses are obtained marking the duration of a fixed number, or set, of cycles of the sampled signal and these timing pulses are employed to control the period of counting of cycles of a higher fixed and known frequency source. The counts of cycles obtained from the fixed frequency source provide a precise measurement of the average frequency of each set of cycles sampled, and thus successive discrete values of the quantity being measured. The frequency of the known frequency source is made such that each measurement is presented as a direct digital representation of the quantity measured.

  5. Correlation Functions Quantify Super-Resolution Images and Estimate Apparent Clustering Due to Over-Counting

    PubMed Central

    Veatch, Sarah L.; Machta, Benjamin B.; Shelby, Sarah A.; Chiang, Ethan N.; Holowka, David A.; Baird, Barbara A.

    2012-01-01

    We present an analytical method using correlation functions to quantify clustering in super-resolution fluorescence localization images and electron microscopy images of static surfaces in two dimensions. We use this method to quantify how over-counting of labeled molecules contributes to apparent self-clustering and to calculate the effective lateral resolution of an image. This treatment applies to distributions of proteins and lipids in cell membranes, where there is significant interest in using electron microscopy and super-resolution fluorescence localization techniques to probe membrane heterogeneity. When images are quantified using pair auto-correlation functions, the magnitude of apparent clustering arising from over-counting varies inversely with the surface density of labeled molecules and does not depend on the number of times an average molecule is counted. In contrast, we demonstrate that over-counting does not give rise to apparent co-clustering in double label experiments when pair cross-correlation functions are measured. We apply our analytical method to quantify the distribution of the IgE receptor (FcεRI) on the plasma membranes of chemically fixed RBL-2H3 mast cells from images acquired using stochastic optical reconstruction microscopy (STORM/dSTORM) and scanning electron microscopy (SEM). We find that apparent clustering of FcεRI-bound IgE is dominated by over-counting labels on individual complexes when IgE is directly conjugated to organic fluorophores. We verify this observation by measuring pair cross-correlation functions between two distinguishably labeled pools of IgE-FcεRI on the cell surface using both imaging methods. After correcting for over-counting, we observe weak but significant self-clustering of IgE-FcεRI in fluorescence localization measurements, and no residual self-clustering as detected with SEM. We also apply this method to quantify IgE-FcεRI redistribution after deliberate clustering by crosslinking with two distinct trivalent ligands of defined architectures, and we evaluate contributions from both over-counting of labels and redistribution of proteins. PMID:22384026

  6. Estimated allele substitution effects underlying genomic evaluation models depend on the scaling of allele counts.

    PubMed

    Bouwman, Aniek C; Hayes, Ben J; Calus, Mario P L

    2017-10-30

    Genomic evaluation is used to predict direct genomic values (DGV) for selection candidates in breeding programs, but also to estimate allele substitution effects (ASE) of single nucleotide polymorphisms (SNPs). Scaling of allele counts influences the estimated ASE, because scaling of allele counts results in less shrinkage towards the mean for low minor allele frequency (MAF) variants. Scaling may become relevant for estimating ASE as more low MAF variants will be used in genomic evaluations. We show the impact of scaling on estimates of ASE using real data and a theoretical framework, and in terms of power, model fit and predictive performance. In a dairy cattle dataset with 630 K SNP genotypes, the correlation between DGV for stature from a random regression model using centered allele counts (RRc) and centered and scaled allele counts (RRcs) was 0.9988, whereas the overall correlation between ASE using RRc and RRcs was 0.27. The main difference in ASE between both methods was found for SNPs with a MAF lower than 0.01. Both the ratio (ASE from RRcs/ASE from RRc) and the regression coefficient (regression of ASE from RRcs on ASE from RRc) were much higher than 1 for low MAF SNPs. Derived equations showed that scenarios with a high heritability, a large number of individuals and a small number of variants have lower ratios between ASE from RRc and RRcs. We also investigated the optimal scaling parameter [from - 1 (RRcs) to 0 (RRc) in steps of 0.1] in the bovine stature dataset. We found that the log-likelihood was maximized with a scaling parameter of - 0.8, while the mean squared error of prediction was minimized with a scaling parameter of - 1, i.e., RRcs. Large differences in estimated ASE were observed for low MAF SNPs when allele counts were scaled or not scaled because there is less shrinkage towards the mean for scaled allele counts. We derived a theoretical framework that shows that the difference in ASE due to shrinkage is heavily influenced by the power of the data. Increasing the power results in smaller differences in ASE whether allele counts are scaled or not.

  7. 78 FR 23830 - Airworthiness Directives; Turbomeca S.A. Turboshaft Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-04-23

    ... daily post-flight checks of the engine tachometer's unit cycle-counting feature. This AD also requires ground-run functional checks within every 1,000 operating hours. This AD was prompted by detailed... Airworthiness Limitation Section (ALS) of Arriel 1 Maintenance Manuals has been updated in order to clarify the...

  8. Microbial Contamination of Chicken Wings: An Open-Ended Laboratory Project.

    ERIC Educational Resources Information Center

    Deutch, Charles E.

    2001-01-01

    Introduces the chicken wing project in which students assess the microbial contamination of chicken wings for the safety of foods. Uses the colony counting technique and direct wash fluid examination for determining the microbial contamination, and investigates methods to reduce the level of microbial contamination. (Contains 14 references.) (YDS)

  9. 45 CFR 261.42 - Which reductions count in determining the caseload reduction credit?

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... AND HUMAN SERVICES ENSURING THAT RECIPIENTS WORK How Will We Determine Caseload Reduction Credit for... requirements or State changes in eligibility rules since FY 2005 that directly affect a family's eligibility..., time limits, full family sanctions, and other new requirements that deny families assistance when an...

  10. Is It Worth It? Benefits in Research with Adults with Intellectual Disability

    ERIC Educational Resources Information Center

    McDonald, Katherine E.; Conroy, Nicole E.; Olick, Robert S.

    2016-01-01

    Including adults with intellectual disability in research promotes direct benefits to participants and larger societal benefits. Stakeholders may have different views of what count as benefits and their importance. We compared views on benefits in research with adults with intellectual disability among adults with intellectual disability, family…

  11. Mycotoxins that affect the North American agri-food sector: state of the art and directions for the future

    USDA-ARS?s Scientific Manuscript database

    This paper summarises workshop discussions at the 5th international MYCORED meeting in Ottawa, Canada (June 2012) with over 200 participants representing academics, government and industry scientists, government officials and farming organisations (present in roughly equal proportions) from 27 count...

  12. 25 CFR 36.20 - Standard V-Minimum academic programs/school calendar.

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ..., physical education, music, etc.) which are directly related to or affect student instruction shall provide... dismissal of students by the school administration, the day may be counted as a school day provided that...-culture and multi-ethnic dimensions designed to enable students to function effectively in a pluralistic...

  13. Relationship between population estimates of cotton fleahoppers (Hemiptera: Miridae) obtained by terminal and whole plant examinations

    USDA-ARS?s Scientific Manuscript database

    The standard sampling technique used to quantify cotton fleahopper, Pseudatomoscelis seriatus (Reuter), abundance in cotton, Gossypium hirsutum L., involves direct counts of adults and nymphs on plants. This method, however, becomes increasingly laborious and time consuming as plants increase in si...

  14. Comparison between Ki67 labeling index determined using image analysis software with virtual slide system and that determined visually in breast cancer.

    PubMed

    Maeda, Ichiro; Abe, Kayoko; Koizumi, Hirotaka; Nakajima, Chika; Tajima, Shinya; Aoki, Hiromi; Tsuchiya, Junichi; Tsuchiya, Seiko; Tsuchiya, Kyoko; Shimo, Arata; Tsugawa, Koichiro; Ueno, Takahiko; Tatsunami, Shinobu; Takagi, Masayuki

    2016-09-01

    In recent papers, Ki67 labeling index (LI) has been used to classify breast cancer patients into the low and high Ki67LI groups for comparison studies, which showed significant differences in many prognostic factors. It has not been clarified whether image analysis software can be used for calculating LI in breast cancer. In our study, we examined whether Ki67LI in breast cancer calculated using image analysis software correlates with that measured on the basis of visual. Fifty patients were randomly selected among breast cancer patients who underwent surgical operation from March, 2010 to May, 2010 in our hospital without preoperative chemotherapy. In this study, for the virtual slide system (VSS: VS120-L100, Olympus, Tokyo, Japan), the high-resolution VSs of all the 50 patients were prepared as samples. The image analysis software use for calculating LI was Tissuemorph Digital Pathology (Tissuemorph DP: Visiopharm, Hoersholm, Denmark). The calculated LI was extracted from 3 to 5 views containing hot spots. The LI calculated using Tissuemorph DP was designed as LI/image/T. The digital image of 3 to 5 LI/image/T views was printed out, and on the digital photograph, we counted visually the number of Ki67-immunopositive cells in exactly the same area, and the percentage of Ki67-immunopositive cells was designed as LI/direct. Moreover, a pathologist's assistant (PA) determined the tumor area in the same specimen using VSS and calculated LI using Tissuemorph DP, which was designed as LI/image/PA. The chief pathologist (CP) similarly calculated LI which was designed as LI/image/CP. We evaluated the degree of agreement between different data sets "LI/image/T and LI/direct" and "LI/image/T, LI/image/CP, and LI/image/PA" by using interclass correlation coefficient (ICC). The average counts of cells were as follows: LI/direct, 3209.7 ± 1970.4 (SD); LI/image/T, 2601.6 ± 1697.1; LI/image/PA, 2886.5 ± 2027.5; LI/image/CP, 18805.5 ± 22293.4. The values of LI/direct and LI/image/T showed almost perfect agreement as showed by an ICC of 0.885 (95 % CI, 0.806-0.933; p < 0.001). The agreement among three investigators was almost perfect. The obtained ICC was 0.825 (95 % CI, 0.739-0.890; p < 0.001) among the data of LI/image/T, LI/image/CP and LI/image/PA. There were five cases that immunopositivity for Ki67 showed a more than 10 % disagreement between LI/direct and LI/image/T. The merits of calculating Ki67 LI using Tissuemorph DP are as follows. First, the staining intensity of the cells to be counted can be adjusted. Second, the portion of a tumor including "hot spots" for counting can be chosen. Third, many cancer cells can be counted more rapidly using Tissuemorph DP than by visual observation. However, it is important that pathologist should check and carry out the final decision of the data, when Ki67 LI using Tissuemorph DP is calculated.

  15. Direct handling of sharp interfacial energy for microstructural evolution

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Hernández–Rivera, Efraín; Tikare, Veena; Noirot, Laurence

    In this study, we introduce a simplification to the previously demonstrated hybrid Potts–phase field (hPPF), which relates interfacial energies to microstructural sharp interfaces. The model defines interfacial energy by a Potts-like discrete interface approach of counting unlike neighbors, which we use to compute local curvature. The model is compared to the hPPF by studying interfacial characteristics and grain growth behavior. The models give virtually identical results, while the new model allows the simulator more direct control of interfacial energy.

  16. Direct handling of sharp interfacial energy for microstructural evolution

    DOE PAGES

    Hernández–Rivera, Efraín; Tikare, Veena; Noirot, Laurence; ...

    2014-08-24

    In this study, we introduce a simplification to the previously demonstrated hybrid Potts–phase field (hPPF), which relates interfacial energies to microstructural sharp interfaces. The model defines interfacial energy by a Potts-like discrete interface approach of counting unlike neighbors, which we use to compute local curvature. The model is compared to the hPPF by studying interfacial characteristics and grain growth behavior. The models give virtually identical results, while the new model allows the simulator more direct control of interfacial energy.

  17. How to normalize metatranscriptomic count data for differential expression analysis.

    PubMed

    Klingenberg, Heiner; Meinicke, Peter

    2017-01-01

    Differential expression analysis on the basis of RNA-Seq count data has become a standard tool in transcriptomics. Several studies have shown that prior normalization of the data is crucial for a reliable detection of transcriptional differences. Until now it has not been clear whether and how the transcriptomic approach can be used for differential expression analysis in metatranscriptomics. We propose a model for differential expression in metatranscriptomics that explicitly accounts for variations in the taxonomic composition of transcripts across different samples. As a main consequence the correct normalization of metatranscriptomic count data under this model requires the taxonomic separation of the data into organism-specific bins. Then the taxon-specific scaling of organism profiles yields a valid normalization and allows us to recombine the scaled profiles into a metatranscriptomic count matrix. This matrix can then be analyzed with statistical tools for transcriptomic count data. For taxon-specific scaling and recombination of scaled counts we provide a simple R script. When applying transcriptomic tools for differential expression analysis directly to metatranscriptomic data with an organism-independent (global) scaling of counts the resulting differences may be difficult to interpret. The differences may correspond to changing functional profiles of the contributing organisms but may also result from a variation of taxonomic abundances. Taxon-specific scaling eliminates this variation and therefore the resulting differences actually reflect a different behavior of organisms under changing conditions. In simulation studies we show that the divergence between results from global and taxon-specific scaling can be drastic. In particular, the variation of organism abundances can imply a considerable increase of significant differences with global scaling. Also, on real metatranscriptomic data, the predictions from taxon-specific and global scaling can differ widely. Our studies indicate that in real data applications performed with global scaling it might be impossible to distinguish between differential expression in terms of transcriptomic changes and differential composition in terms of changing taxonomic proportions. As in transcriptomics, a proper normalization of count data is also essential for differential expression analysis in metatranscriptomics. Our model implies a taxon-specific scaling of counts for normalization of the data. The application of taxon-specific scaling consequently removes taxonomic composition variations from functional profiles and therefore provides a clear interpretation of the observed functional differences.

  18. Is hand hygiene before putting on nonsterile gloves in the intensive care unit a waste of health care worker time?--a randomized controlled trial.

    PubMed

    Rock, Clare; Harris, Anthony D; Reich, Nicholas G; Johnson, J Kristie; Thom, Kerri A

    2013-11-01

    Hand hygiene (HH) is recognized as a basic effective measure in prevention of nosocomial infections. However, the importance of HH before donning nonsterile gloves is unknown, and few published studies address this issue. Despite the lack of evidence, the World Health Organization and other leading bodies recommend this practice. The aim of this study was to assess the utility of HH before donning nonsterile gloves prior to patient contact. A prospective, randomized, controlled trial of health care workers entering Contact Isolation rooms in intensive care units was performed. Baseline finger and palm prints were made from dominant hands onto agar plates. Health care workers were then randomized to directly don nonsterile gloves or perform HH and then don nonsterile gloves. Postgloving finger and palm prints were then made from the gloved hands. Plates were incubated and colony-forming units (CFU) of bacteria were counted. Total bacterial colony counts of gloved hands did not differ between the 2 groups (6.9 vs 8.1 CFU, respectively, P = .52). Staphylococcus aureus was identified from gloves (once in "hand hygiene prior to gloving" group, twice in "direct gloving" group). All other organisms were expected commensal flora. HH before donning nonsterile gloves does not decrease already low bacterial counts on gloves. The utility of HH before donning nonsterile gloves may be unnecessary. Copyright © 2013 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Mosby, Inc. All rights reserved.

  19. Selecting exposure measures in crash rate prediction for two-lane highway segments.

    PubMed

    Qin, Xiao; Ivan, John N; Ravishanker, Nalini

    2004-03-01

    A critical part of any risk assessment is identifying how to represent exposure to the risk involved. Recent research shows that the relationship between crash count and traffic volume is non-linear; consequently, a simple crash rate computed as the ratio of crash count to volume is not proper for comparing the safety of sites with different traffic volumes. To solve this problem, we describe a new approach for relating traffic volume and crash incidence. Specifically, we disaggregate crashes into four types: (1) single-vehicle, (2) multi-vehicle same direction, (3) multi-vehicle opposite direction, and (4) multi-vehicle intersecting, and define candidate exposure measures for each that we hypothesize will be linear with respect to each crash type. This paper describes initial investigation using crash and physical characteristics data for highway segments in Michigan from the Highway Safety Information System (HSIS). We use zero-inflated-Poisson (ZIP) modeling to estimate models for predicting counts for each of the above crash types as a function of the daily volume, segment length, speed limit and roadway width. We found that the relationship between crashes and the daily volume (AADT) is non-linear and varies by crash type, and is significantly different from the relationship between crashes and segment length for all crash types. Our research will provide information to improve accuracy of crash predictions and, thus, facilitate more meaningful comparison of the safety record of seemingly similar highway locations.

  20. Hematologic, Plasma Biochemical, and Lipid Panel Reference Intervals in Orange-winged Amazon Parrots ( Amazona amazonica ).

    PubMed

    Vergneau-Grosset, Claire; Polley, Tamsen; Holt, Danielle Carrade; Vernau, William; Paul-Murphy, Joanne

    2016-12-01

    To establish reference intervals in orange-winged Amazon parrots ( Amazona amazonica ) for the complete blood count, plasma biochemical values, and lipid panel and to evaluate age- and sex-related variations, blood samples were obtained from 29 healthy juvenile and adult parrots. Concentrations of total protein, bile acids, phosphorus, total cholesterol, low-density-lipoprotein cholesterol (LDL-C), and high-density lipoprotein cholesterol were significantly higher in adult compared with juvenile birds, while uric acid concentration was significantly higher in juveniles. The white blood cell count, lymphocyte count, and phosphorus and potassium concentrations were significantly higher in females, while chloride concentration was significantly higher in males. In this species, direct measurement of LDL-C resulted in lower concentrations than LDL-C calculated with the Friedewald formula. Assessment of the agreement between the calculated and measured LDL-C concentrations indicated a systematic bias of 19.1 mg/dL and a proportional bias of 1.07. A correction factor of -19 mg/L could be applied to the Friedewald formula, to obtain a result closer to the measured LDL-C, providing clinically acceptable (<20% difference) agreement in 66% of the samples. Triglyceride concentrations within the range measured in healthy birds of the present study did not significantly affect the bias between calculated and directly measured LDL-C. Further studies are needed to investigate the impact of nutritional factors, genetics, and exercise on biochemistry and lipoprotein panel analytes in orange-winged Amazon parrots.

  1. Adaptively Reevaluated Bayesian Localization (ARBL). A Novel Technique for Radiological Source Localization

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Miller, Erin A.; Robinson, Sean M.; Anderson, Kevin K.

    2015-01-19

    Here we present a novel technique for the localization of radiological sources in urban or rural environments from an aerial platform. The technique is based on a Bayesian approach to localization, in which measured count rates in a time series are compared with predicted count rates from a series of pre-calculated test sources to define likelihood. Furthermore, this technique is expanded by using a localized treatment with a limited field of view (FOV), coupled with a likelihood ratio reevaluation, allowing for real-time computation on commodity hardware for arbitrarily complex detector models and terrain. In particular, detectors with inherent asymmetry ofmore » response (such as those employing internal collimation or self-shielding for enhanced directional awareness) are leveraged by this approach to provide improved localization. Our results from the localization technique are shown for simulated flight data using monolithic as well as directionally-aware detector models, and the capability of the methodology to locate radioisotopes is estimated for several test cases. This localization technique is shown to facilitate urban search by allowing quick and adaptive estimates of source location, in many cases from a single flyover near a source. In particular, this method represents a significant advancement from earlier methods like full-field Bayesian likelihood, which is not generally fast enough to allow for broad-field search in real time, and highest-net-counts estimation, which has a localization error that depends strongly on flight path and cannot generally operate without exhaustive search« less

  2. Comparative investigation of the detective quantum efficiency of direct and indirect conversion detector technologies in dedicated breast CT.

    PubMed

    Kuttig, Jan D; Steiding, Christian; Kolditz, Daniel; Hupfer, Martin; Karolczak, Marek; Kalender, Willi A

    2015-06-01

    To investigate the dose saving potential of direct-converting CdTe photon-counting detector technology for dedicated breast CT. We analyzed the modulation transfer function (MTF), the noise power spectrum (NPS) and the detective quantum efficiency (DQE) of two detector technologies, suitable for breast CT (BCT): a flat-panel energy-integrating detector with a 70 μm and a 208 μm thick gadolinium oxysulfide (GOS) and a 150 μm thick cesium iodide (CsI) scintillator and a photon-counting detector with a 1000 μm thick CdTe sensor. The measurements for GOS scintillator thicknesses of 70 μm and 208 μm delivered 10% pre-sampled MTF values of 6.6 mm(-1) and 3.2 mm(-1), and DQE(0) values of 23% and 61%. The 10% pre-sampled MTF value for the 150 μm thick CsI scintillator 6.9 mm(-1), and the DQE(0) value was 49%. The CdTe sensor reached a 10% pre-sampled MTF value of 8.5 mm(-1) and a DQE(0) value of 85%. The photon-counting CdTe detector technology allows for significant dose reduction compared to the energy-integrating scintillation detector technology used in BCT today. Our comparative evaluation indicates that a high potential dose saving may be possible for BCT by using CdTe detectors, without loss of spatial resolution. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  3. Direct and indirect mortality in Florida during the 2004 hurricane season

    NASA Astrophysics Data System (ADS)

    McKinney, Nathan; Houser, Chris; Meyer-Arendt, Klaus

    2011-07-01

    Previous studies have shown that natural disasters, and hurricanes in particular, have led to more deaths than those usually documented in short post-storm surveys. Such indirect deaths, thought to be related to dietary, stress or pre-existing medical conditions, can exceed the number of direct deaths and may persist for weeks or even months beyond the event itself. In the present study, cumulative sum of deviations plots are used to quantify the number of direct and indirect deaths resulting from Hurricanes Charley, Frances, Ivan and Jeanne that made landfall in Florida in 2004. Results suggest that there was an elevated mortality for up to 2 months following each storm, resulting in a total of 624 direct and indirect deaths attributable to the storm. Trauma-related deaths that can be associated directly with the storm account for only ˜4% of the total storm-related mortality, while indirect mortality accounts for most storm-related deaths. Specifically, a large percentage of the elevated mortality was associated with heart (34%) and cancer-related deaths (19%), while diabetes (5%) and accident-related deaths (9%) account for a smaller but still significant percentage of the elevated mortality. The results further suggest that the elevated mortality was the result of additional deaths that would not have otherwise occurred within that 5 month period, and not simply a clustering of deaths that were inevitable between 1 August and 31 December 2004. The elevated mortality identified in this study is significantly greater than the official count of 31 direct and 113 indirect deaths resulting from the four hurricanes combined. This suggests a need for improved mortality counts and surveillance in order to better evaluate and identify effective prevention policies, and to identify preventable deaths.

  4. Seasonal Levels of the Vibrio Predator Bacteriovorax in Atlantic, Pacific, and Gulf Coast Seawater

    PubMed Central

    Richards, Gary P.; Watson, Michael A.; Boyd, E. Fidelma; Burkhardt, William; Lau, Ronald; Uknalis, Joseph; Fay, Johnna P.

    2013-01-01

    Bacteriovorax were quantified in US Atlantic, Gulf, and Pacific seawater to determine baseline levels of these predatory bacteria and possible seasonal fluctuations in levels. Surface seawater was analyzed monthly for 1 year from Kailua-Kona, Hawaii; the Gulf Coast of Alabama; and four sites along the Delaware Bay. Screening for Bacteriovorax was performed on lawns of V. parahaemolyticus host cells. Direct testing of 7.5 mL portions of seawater from the Atlantic, Pacific, and Gulf coasts gave mean annual counts ≤12.2 PFU. Spikes in counts were observed at 3 out of 4 sites along the Delaware Bay 1 week after Hurricane Sandy. A comparison of summer versus winter counts showed significantly more Bacteriovorax (P ≤ 0.0001) in the Delaware Bay during the summer and significantly more (P ≤ 0.0001) in the Gulf during the winter, but no significant seasonal differences (P > 0.05) for Hawaiian seawater. Bacteriovorax counts only correlated with seawater salinity and temperature at one Delaware site (r = 0.79 and r = 0.65, resp.). There was a relatively strong negative correlation between temperature and Bacteriovorax levels (r = −0.585) for Gulf seawater. Selected isolates were sequenced and identified by phylogenetic analysis as Bacteriovorax clusters IX, X, XI, and XII. PMID:24454382

  5. Spatiotemporal Dynamics of Total Viable Vibrio spp. in a NW Mediterranean Coastal Area.

    PubMed

    Girard, Léa; Peuchet, Sébastien; Servais, Pierre; Henry, Annabelle; Charni-Ben-Tabassi, Nadine; Baudart, Julia

    2017-09-27

    A cellular approach combining Direct Viable Counting and Fluorescent In Situ Hybridization using a one-step multiple-probe technique and Solid Phase Cytometry (DVC-FISH-SPC) was developed to monitor total viable vibrios and cover the detection of a large diversity of vibrios. FISH combined three probes in the same assay and targeted sequences located at different positions on the 16S rRNA of Vibrio and Aliivibrio members. We performed a 10-month in situ study to investigate the weekly dynamics of viable vibrios relative to culturable counts at two northwestern Mediterranean coastal sites, and identified the key physicochemical factors for their occurrence in water using a multivariate analysis. Total viable and culturable cell counts showed the same temporal pattern during the warmer season, whereas the ratios between both methods were inverted during the colder seasons (<15°C), indicating that some of the vibrio community had entered into a viable but non-culturable (VBNC) state. We confirmed that Seawater Surface Temperature explained 51-62% of the total variance in culturable counts, and also showed that the occurrence of viable vibrios is controlled by two variables, pheopigment (15%) and phosphate (12%) concentrations, suggesting that other unidentified factors play a role in maintaining viability.

  6. A Review of Multivariate Distributions for Count Data Derived from the Poisson Distribution

    PubMed Central

    Inouye, David; Yang, Eunho; Allen, Genevera; Ravikumar, Pradeep

    2017-01-01

    The Poisson distribution has been widely studied and used for modeling univariate count-valued data. Multivariate generalizations of the Poisson distribution that permit dependencies, however, have been far less popular. Yet, real-world high-dimensional count-valued data found in word counts, genomics, and crime statistics, for example, exhibit rich dependencies, and motivate the need for multivariate distributions that can appropriately model this data. We review multivariate distributions derived from the univariate Poisson, categorizing these models into three main classes: 1) where the marginal distributions are Poisson, 2) where the joint distribution is a mixture of independent multivariate Poisson distributions, and 3) where the node-conditional distributions are derived from the Poisson. We discuss the development of multiple instances of these classes and compare the models in terms of interpretability and theory. Then, we empirically compare multiple models from each class on three real-world datasets that have varying data characteristics from different domains, namely traffic accident data, biological next generation sequencing data, and text data. These empirical experiments develop intuition about the comparative advantages and disadvantages of each class of multivariate distribution that was derived from the Poisson. Finally, we suggest new research directions as explored in the subsequent discussion section. PMID:28983398

  7. Handheld 2-channel impedimetric cell counting system with embedded real-time processing

    NASA Astrophysics Data System (ADS)

    Rottigni, A.; Carminati, M.; Ferrari, G.; Vahey, M. D.; Voldman, J.; Sampietro, M.

    2011-05-01

    Lab-on-a-chip systems have been attracting a growing attention for the perspective of miniaturization and portability of bio-chemical assays. Here we present a the design and characterization of a miniaturized, USB-powered, self-contained, 2-channel instrument for impedance sensing, suitable for label-free tracking and real-time detection of cells flowing in microfluidic channels. This original circuit features a signal generator based on a direct digital synthesizer, a transimpedance amplifier, an integrated square-wave lock-in coupled to a Σ▵ ADC converter, and a digital processing platform. Real-time automatic peak detection on two channels is implemented in a FPGA. System functionality has been tested with an electronic resistance modulator to simulate 1% impedance variation produced by cells, reaching a time resolution of 50μs (enabling a count rate of 2000 events/s) with an applied voltage as low as 200mV. Biological experiments have been carried out counting yeast cells. Statistical analysis of events is in agreement with the expected amplitude and time distributions. 2-channel yeast counting has been performed with concomitant dielectrophoretic cell separation, showing that this novel and ultra compact sensing system, thanks to the selectivity of the lock-in detector, is compatible with other AC electrical fields applied to the device.

  8. Adherence to hepatitis A virus vaccination in HIV-infected men who have sex with men.

    PubMed

    Kourkounti, Sofia; Paparizos, Vassilios; Leuow, Kirsten; Paparizou, Eleni; Antoniou, Christina

    2015-10-01

    Although vaccination against hepatitis A virus (HAV) is essential for human immunodeficiency virus (HIV)-infected patients, the uptake of HAV vaccine is reported to be very low. From 2007 to 2012, 912 HIV-infected men in Athens, Greece were screened for exposure to HAV. Two doses of an HAV vaccine were recommended to 569 eligible patients. Reminder cards with scheduled vaccination visits were given to each patient. Among eligible patients, 62.2% (354/569) received both doses. Patients who were fully vaccinated compared with non-adherent patients were natives, older, had undetectable HIV viral load, higher CD4 T cell counts and lower nadir CD4 T cell counts. Multivariate logistic regression revealed that the patient's country of origin (p = 0.024; OR = 2.712; 95% CI, 1.139-6.457), CD4 T cell count (p < 0.001) and nadir CD4 T cell count (p < 0.001) were factors directly associated with adherence. In conclusion, adherence to HAV vaccination was better than in previously published data. Because many of the factors related to vaccination completion are parameters of HIV infection, it appears that physician interest in HIV care and vaccination planning is crucial to enhancing vaccine uptake. © The Author(s) 2015.

  9. Musculoskeletal imaging with a prototype photon-counting detector.

    PubMed

    Gruber, M; Homolka, P; Chmeissani, M; Uffmann, M; Pretterklieber, M; Kainberger, F

    2012-01-01

    To test a digital imaging X-ray device based on the direct capture of X-ray photons with pixel detectors, which are coupled with photon-counting readout electronics. The chip consists of a matrix of 256 × 256 pixels with a pixel pitch of 55 μm. A monolithic image of 11.2 cm × 7 cm was obtained by the consecutive displacement approach. Images of embalmed anatomical specimens of eight human hands were obtained at four different dose levels (skin dose 2.4, 6, 12, 25 μGy) with the new detector, as well as with a flat-panel detector. The overall rating scores for the evaluated anatomical regions ranged from 5.23 at the lowest dose level, 6.32 at approximately 6 μGy, 6.70 at 12 μGy, to 6.99 at the highest dose level with the photon-counting system. The corresponding rating scores for the flat-panel detector were 3.84, 5.39, 6.64, and 7.34. When images obtained at the same dose were compared, the new system outperformed the conventional DR system at the two lowest dose levels. At the higher dose levels, there were no significant differences between the two systems. The photon-counting detector has great potential to obtain musculoskeletal images of excellent quality at very low dose levels.

  10. GIANT GROUND LEVEL ENHANCEMENT OF RELATIVISTIC SOLAR PROTONS ON 2005 JANUARY 20. I. SPACESHIP EARTH OBSERVATIONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Bieber, J. W.; Clem, J.; Evenson, P.

    A ground level enhancement (GLE) is a solar event that accelerates ions (mostly protons) to GeV range energies in such great numbers that ground-based detectors, such as neutron monitors, observe their showers in Earth's atmosphere above the Galactic cosmic ray background. GLEs are of practical interest because an enhanced relativistic ion flux poses a hazard to astronauts, air crews, and aircraft electronics, and provides the earliest direct indication of an impending space radiation storm. The giant GLE of 2005 January 20 was the second largest on record (and largest since 1956), with up to 4200% count rate enhancement at seamore » level. We analyzed data from the Spaceship Earth network, supplemented to comprise 13 polar neutron monitor stations with distinct asymptotic viewing directions and Polar Bare neutron counters at South Pole, to determine the time evolution of the relativistic proton density, energy spectrum, and three-dimensional directional distribution. We identify two energy-dispersive peaks, indicating two solar injections. The relativistic solar protons were initially strongly beamed, with a peak maximum-to-minimum anisotropy ratio over 1000:1. The directional distribution is characterized by an axis of symmetry, determined independently for each minute of data, whose angle from the magnetic field slowly varied from about 60 Degree-Sign to low values and then rose to about 90 Degree-Sign . The extremely high relativistic proton flux from certain directions allowed 10 s tracking of count rates, revealing fluctuations of period {approx}> 2 minutes with up to 50% fractional changes, which we attribute to fluctuations in the axis of symmetry.« less

  11. Silicone Oil Microdroplets and Protein Aggregates in Repackaged Bevacizumab and Ranibizumab: Effects of Long-term Storage and Product Mishandling

    PubMed Central

    Liu, Lu; Ammar, David A.; Ross, Lindsey A.; Mandava, Naresh; Kahook, Malik Y.

    2011-01-01

    Purpose. To quantify levels of subvisible particles and protein aggregates in repackaged bevacizumab obtained from compounding pharmacies, as well as in samples of bevacizumab and ranibizumab tested in controlled laboratory experiments. Methods. Repackaged bevacizumab was purchased from four external compounding pharmacies. For controlled laboratory studies, bevacizumab and placebo were drawn into plastic syringes and incubated at −20°C, 4°C, and room temperature (with and without exposure to light) for 12 weeks. In addition, mechanical shock occurring during shipping was mimicked with syringes containing bevacizumab. Particle counts and size distributions were quantified by particle characterization technology. Levels of monomer and soluble aggregates of bevacizumab were determined with size-exclusion high-performance liquid chromatography (SE-HPLC). Results. Repackaged bevacizumab from the compounding pharmacies had a wide range of particle counts (89,006 ± 56,406 to 602,062 ± 18,349/mL). Bevacizumab sampled directly from the original glass vial had particle counts of 63,839 ± 349/mL. There was up to a 10% monomer loss in the repackaged bevacizumab. Laboratory samples of repackaged bevacizumab and placebo had initial particle counts, respectively, of 283,675 ± 60,494/mL and 492,314 ± 389,361/mL. Freeze-thawing of both bevacizumab and placebo samples led to >1.2 million particles/mL. In all repackaged samples, most of the particles were due to silicone oil. SE-HPLC showed no significant differences for repackaged samples incubated in the laboratory under various conditions, compared with bevacizumab directly from vial. However, repeated freeze-thawing caused a more than 10% monomer loss. Conclusions. Bevacizumab repackaged in plastic syringes could contain protein aggregates and is contaminated by silicone oil microdroplets. Freeze-thawing or other mishandling can further increase levels of particle contaminants. PMID:21051703

  12. The efficacy of ultrasound treatment as a reversible male contraceptive in the rhesus monkey.

    PubMed

    VandeVoort, Catherine A; Tollner, Theodore L

    2012-09-12

    The use of therapeutic ultrasound as a contraceptive approach has involved nonhuman primates as well as rats and dogs. The current study was undertaken to determine whether this treatment could be a method for reversible contraception, using a model with testes size similar to adult humans. Two methods of ultrasound exposure were used, either the transducer probe at the bottom of a cup filled with saline (Cup) or direct application to the surface of the scrotum (Direct). Four adult rhesus (Macaca mulatta) males with normal semen parameters were treated with therapeutic ultrasound at 2.5 W/cm(2) for 30 min. Treatment was given 3 times, one every other day on a Monday-Wednesday-Friday schedule. For each male, semen quality was evaluated a minimum of three times over several months prior to ultrasound exposure and weekly for two months following ultrasound treatment. Semen samples from all males, regardless of exposure method, exhibited a decrease in the percentage of motile sperm following ultrasound treatment. There was an average reduction in motility of 40% the week following treatment. Similarly, curvilinear velocity and the percentage of sperm with a normally shaped flagellum were also reduced in all males following ultrasound treatment. A significant reduction in the total number of sperm in an ejaculate (total sperm count) was only observed in males that received ultrasound via the cup method. Following treatment via the cup method, males exhibited up to a 91.7% decrease in average total sperm count (n = 2). Sperm count did not approach pre-treatment levels until 8 weeks following ultrasound exposure. The sustained reduction in sperm count, percent motility, normal morphology, and sperm vigor with the cup exposure method provides proof of principle that testicular treatment with ultrasound can be an effective contraceptive approach in humans.

  13. Lipids and leukocytes in newborn umbilical vein blood, birth weight and maternal body mass index.

    PubMed

    Brittos, T; de Souza, W B; Anschau, F; Pellanda, L

    2016-12-01

    Maternal obesity during pregnancy may influence fetal development and possibly predispose offspring to cardiovascular disease. The aim of the present study was to evaluate the relationship between maternal pre-pregnancy body mass index (BMI) and weight gain during pregnancy, and newborn birth weight, with lipid profile, high-sensitivity C-reactive protein (hs-CRP) and leukocyte in newborns. We performed a cross-sectional study of 245 mothers and their children. Blood was collected from the umbilical vein and assayed for lipid profile, hs-CRP and leukocyte count. Newborns average weight was 3241 g, total cholesterol 53.9 mg/dl, high-density lipoprotein cholesterol (HDL-c) 21.9 mg/dl, low-density lipoprotein cholesterol (LDL-c) 26.2 mg/dl, triglyceride 29.5 mg/dl and leukocytes 13,777/mm3. There was a direct correlation of pre-pregnancy BMI of overweight mothers with total cholesterol (r=0.220, P=0.037) and LDL-c (r=0.268, P=0.011) of newborns. Total cholesterol, LDL-c and HDL-c were higher in pre-term newborns (66.3±19.7, 35.9±14.6 and 25.2±7.7 mg/dl, respectively) that in full-term (52.4±13.1, 25.0±8.7 and 21.5±6.0 mg/dl), with P=0.001, 0.001 and 0.003, respectively. Leukocyte counts were higher in full-term newborns (14,268±3982/mm3) compared with pre-term (9792±2836/mm3, P<0.0001). There was a direct correlation between birth weight and leukocyte counts of newborns (r=0.282, P<0.0001). These results suggest the possible interaction of maternal weight and fetal growth with lipid metabolism and leukocyte count in the newborn, which may be linked to programming of the immune system.

  14. Modern Measurements of Uranium Decay Rates

    NASA Astrophysics Data System (ADS)

    Parsons-Moss, T.; Faye, S. A.; Williams, R. W.; Wang, T. F.; Renne, P. R.; Mundil, R.; Harrison, M.; Bandong, B. B.; Moody, K.; Knight, K. B.

    2015-12-01

    It has been widely recognized that accurate and precise decay constants (λ) are critical to geochronology as highlighted by the EARTHTIME initiative, particularly the calibration benchmarks λ235U and λ238U. [1] Alpha counting experiments in 1971[2] measured λ235U and λ238U with ~0.1% precision, but have never been independently validated. We are embarking on new direct measurements of λ235U, λ238U, λ234Th, and λ234U using independent approaches for each nuclide. For the measurement of λ235U, highly enriched 235U samples will be chemically purified and analyzed for U concentration and isotopic composition by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Thin films will be electrodeposited from these solutions and the α activity will be measured in an α-γ coincidence counting apparatus, which allows reduced uncertainty in counting efficiency while achieving adequate counting statistics. For λ238U measurement we will measure ingrowth of 234Th in chemically purified, isotopically enriched 238U solutions, by quantitatively separating the Th and allowing complete decay to 234U. All of the measurements will be done using MC-ICP-MS aiming at 0.05% precision. This approach is expected to result in values of λ238U with less than 0.1% uncertainty, if combined with improved λ234Th measements. These will be achieved using direct decay measurements with an E-ΔE charged particle telescope in coincidence with a gamma detector. This system allows measurement of 234Th β-decay and simultaneous detection and identification of α particles emitted by the 234U daughter, thus observing λ234U at the same time. The high-precision λ234U obtained by the direct activity measurements can independently verify the commonly used values obtained by indirect methods.[3] An overarching goal of the project is to ensure the quality of results including metrological traceability in order to facilitate implementation across diverse disciplines. [1] T.M. Harrison et al., (2015) It's About Time:Opportunities and Challenges for U.S. Geological Survey. Institute of Geophysics and Planetary Physics Publication 6539, University of California, Los Angeles [2] A. H. Jaffey et al., Physical Review C, 4, 5, (1971), 1889-1906 [3] H. Cheng et al., Chemical Geology, 169, (2000), 17-33

  15. Counting the Full Cost: Parental and Community Financing of Education in East Asia. Directions in Development Series.

    ERIC Educational Resources Information Center

    Bray, Mark

    This collaborative report focuses on nine countries in East Asia: Cambodia, China, Indonesia, Lao People's Democratic Republic, Mongolia, Myanmar, the Philippines, Thailand, and Vietnam. While acknowledging that these countries share some common features, the report also highlights each country's particular characteristics and the implications of…

  16. 25 CFR 543.2 - What are the definitions for this part?

    Code of Federal Regulations, 2013 CFR

    2013-04-01

    ..., mechanical, or other technologic form, that function together to aid the play of one or more Class II games... a particular game, player interface, shift, or other period. Count room. A secured room where the... validated directly by a voucher system. Dedicated camera. A video camera that continuously records a...

  17. Childhood Lead Poisoning: Rhode Island Kids Count Issue Brief.

    ERIC Educational Resources Information Center

    Rhode Island KIDS COUNT, Providence.

    Noting that childhood lead poisoning is one of the most common preventable pediatric health problems, this report examines lead poisoning as a health problem to which infants and young children are most susceptible and as a housing problem directly related to a shortage of safe, affordable housing. The report details screening rates in Rhode…

  18. COMPARISON OF THE EFFECT OF AMERICAN BISON AND CATTLE ON PASTURE AND DIRECT ACCESS STREAMS

    EPA Science Inventory

    If the Bison are managed in a low impact method then we can count on meat that is free of antibiotics, added hormones, and other industry byproducts. In fact, Federal regulations prohibit the use of artificial growth hormones in bison, and industry protocols prohibit the use ...

  19. 20 CFR 418.3405 - What types of resources do we count?

    Code of Federal Regulations, 2010 CFR

    2010-04-01

    ... of resources that are ordinarily liquid are stocks, bonds, mutual fund shares, promissory notes... accounts (IRA), 401(k) accounts), trusts if they are revocable, funds in an irrevocable trust if the trust beneficiary can direct the use of the funds, and similar items. We will presume that these types of resources...

  20. 20 CFR 418.3405 - What types of resources do we count?

    Code of Federal Regulations, 2011 CFR

    2011-04-01

    ... resources that are ordinarily liquid include: stocks, bonds, mutual fund shares, promissory notes, mortgages... accounts or 401(k) accounts), revocable trusts, funds in an irrevocable trust if the trust beneficiary can direct the use of the funds, and similar items. We will presume that these types of resources can be...

  1. A pebble count procedure for assessing watershed cumulative effects

    Treesearch

    Gregory S. Bevenger; Rudy M. King

    1995-01-01

    Land mangement activities can result in the delivery of fine sediment to streams. Over time, such delivery can lead to cumulative impacts to the aquactic ecosystem. Because numerous laws require Federal land managers to analyze watershed cumulative effects, field personnel need simple monitoring procedures that can be used directly and consistently. One approach to...

  2. 77 FR 55166 - Airworthiness Directives; Sikorsky Aircraft Corporation (Sikorsky) Model Helicopters

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-09-07

    ... ``partial cycle event,'' specify a method of calculating the low cycle fatigue (LCF) life limit using... or continuing to count the full and partial low fatigue cycle events and recording on the component... distinction; and 4. Will not have a significant economic impact, positive or negative, on a substantial number...

  3. Operator Priming and Generalization of Practice in Adults' Simple Arithmetic

    ERIC Educational Resources Information Center

    Chen, Yalin; Campbell, Jamie I. D.

    2016-01-01

    There is a renewed debate about whether educated adults solve simple addition problems (e.g., 2 + 3) by direct fact retrieval or by fast, automatic counting-based procedures. Recent research testing adults' simple addition and multiplication showed that a 150-ms preview of the operator (+ or ×) facilitated addition, but not multiplication,…

  4. 7 CFR 457.133 - Prune crop insurance provisions.

    Code of Federal Regulations, 2014 CFR

    2014-01-01

    ...) Earthquake; (5) Volcanic eruption; (6) Failure of the irrigation water supply, if due to a cause specified in... fresh fruit. We will conduct an appraisal that will be used to determine your production to count for production that is sold by direct marketing or is sold as fresh fruit production. If damage occurs after this...

  5. 7 CFR 457.133 - Prune crop insurance provisions.

    Code of Federal Regulations, 2013 CFR

    2013-01-01

    ...) Earthquake; (5) Volcanic eruption; (6) Failure of the irrigation water supply, if due to a cause specified in... fresh fruit. We will conduct an appraisal that will be used to determine your production to count for production that is sold by direct marketing or is sold as fresh fruit production. If damage occurs after this...

  6. 78 FR 47235 - Airworthiness Directives; General Electric Company Turbofan Engines

    Federal Register 2010, 2011, 2012, 2013, 2014

    2013-08-05

    ... revenue flight cycles. These parts were then installed into engines and introduced into revenue service... cycle counts of those LLPs to account for the additional low cycle fatigue (LCF) life consumed during... Boeing 747-8 flight tests had consumed more cyclic life than they would have in revenue flight cycles...

  7. 47 CFR 36.156 - Interexchange Cable and Wire Facilities (C&WF)-Category 3-apportionment procedures.

    Code of Federal Regulations, 2011 CFR

    2011-10-01

    ... cost per equivalent interexchange telephone circuit kilometer for all circuits in Category 3 is determined and applied to the equivalent interexchange telephone circuit kilometer counts of each of the... Interexchange Cable and Wire Facilities C&WF where feasible. All study areas shall apportion the non-directly...

  8. 47 CFR 36.156 - Interexchange Cable and Wire Facilities (C&WF)-Category 3-apportionment procedures.

    Code of Federal Regulations, 2013 CFR

    2013-10-01

    ... cost per equivalent interexchange telephone circuit kilometer for all circuits in Category 3 is determined and applied to the equivalent interexchange telephone circuit kilometer counts of each of the... Interexchange Cable and Wire Facilities C&WF where feasible. All study areas shall apportion the non-directly...

  9. 47 CFR 36.156 - Interexchange Cable and Wire Facilities (C&WF)-Category 3-apportionment procedures.

    Code of Federal Regulations, 2012 CFR

    2012-10-01

    ... cost per equivalent interexchange telephone circuit kilometer for all circuits in Category 3 is determined and applied to the equivalent interexchange telephone circuit kilometer counts of each of the... Interexchange Cable and Wire Facilities C&WF where feasible. All study areas shall apportion the non-directly...

  10. 47 CFR 36.156 - Interexchange Cable and Wire Facilities (C&WF)-Category 3-apportionment procedures.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... cost per equivalent interexchange telephone circuit kilometer for all circuits in Category 3 is determined and applied to the equivalent interexchange telephone circuit kilometer counts of each of the... Interexchange Cable and Wire Facilities C&WF where feasible. All study areas shall apportion the non-directly...

  11. 77 FR 67261 - Airworthiness Directives; Aeronautical Accessories, Inc., High Landing Gear Forward Crosstube...

    Federal Register 2010, 2011, 2012, 2013, 2014

    2012-11-09

    ... assemblies (crosstubes) installed on Agusta S.p.A. (Agusta) Model AB412 and AB412EP; and Bell Helicopter... based on a supplemental type certificate (STC). This AD requires counting and recording the total number.... ADDRESSES: For service information identified in this AD, contact Aeronautical Accessories, Inc., P.O. Box...

  12. Risk communication with Fukushima residents affected by the Fukushima Daiichi accident at whole-body counting

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Gunji, I.; Furuno, A.; Yonezawa, R.

    After the Tokyo Electric Power Company (TEPCO) Fukushima Daiichi nuclear power plant accident, the Tokai Research and Development Center of the Japan Atomic Energy Agency (JAEA) have had direct dialogue as risk communication with Fukushima residents who underwent whole-body counting examination (WBC). The purpose of the risk communication was to exchange information and opinions about radiation in order to mitigate Fukushima residents' anxiety and stress. Two kinds of opinion surveys were performed: one survey evaluated residents' views of the nuclear accident itself and the second survey evaluated the management of WBC examination as well as the quality of JAEA's communicationmore » skills on risks. It appears that most Fukushima residents seem to have reduced their anxiety level after the direct dialogue. The results of the surveys show that Fukushima residents have the deepest anxiety and concern about their long-term health issues and that they harbor anger toward the government and TEPCO. On the other hand, many WBC patients and patients' relatives have expressed gratitude for help in reducing their feelings of anxiety.« less

  13. Medipix2 based CdTe microprobe for dental imaging

    NASA Astrophysics Data System (ADS)

    Vykydal, Z.; Fauler, A.; Fiederle, M.; Jakubek, J.; Svestkova, M.; Zwerger, A.

    2011-12-01

    Medical imaging devices and techniques are demanded to provide high resolution and low dose images of samples or patients. Hybrid semiconductor single photon counting devices together with suitable sensor materials and advanced techniques of image reconstruction fulfil these requirements. In particular cases such as the direct observation of dental implants also the size of the imaging device itself plays a critical role. This work presents the comparison of 2D radiographs of tooth provided by a standard commercial dental imaging system (Gendex 765DC X-ray tube with VisualiX scintillation detector) and two Medipix2 USB Lite detectors one equipped with a Si sensor (300 μm thick) and one with a CdTe sensor (1 mm thick). Single photon counting capability of the Medipix2 device allows virtually unlimited dynamic range of the images and thus increases the contrast significantly. The dimensions of the whole USB Lite device are only 15 mm × 60 mm of which 25% consists of the sensitive area. Detector of this compact size can be used directly inside the patients' mouth.

  14. An observational study of spectators’ step counts and reasons for attending a professional golf tournament in Scotland

    PubMed Central

    Murray, Andrew D; Turner, Kieran; Archibald, Daryll; Schiphorst, Chloe; Griffin, Steffan Arthur; Scott, Hilary; Hawkes, Roger; Kelly, Paul; Grant, Liz; Mutrie, Nanette

    2017-01-01

    Background Spectators at several hundred golf tournaments on six continents worldwide may gain health-enhancing physical activity (HEPA) during their time at the event. This study aims to investigate spectators’ reasons for attending and assess spectator physical activity (PA) (measured by step count). Methods Spectators at the Paul Lawrie Matchplay event in Scotland (August 2016) were invited to take part in this study. They were asked to complete a brief questionnaire with items to assess (1) demographics, (2) reasons for attendance and (3) baseline PA. In addition, participants were requested to wear a pedometer from time of entry to the venue until exit. Results A total of 339 spectators were recruited to the study and out of which 329 (97.2%) returned step-count data. Spectators took a mean of 11 589 steps (SD 4531). ‘Fresh air’ (rated median 9 out of 10) then ‘watching star players’, ‘exercise/physical activity’, ‘time with friends and family’ and ‘atmosphere’ (all median 8 out of 10) were rated the most important reasons for attending. Conclusion This study is the first to assess spectator physical activity while watching golf (measured by step count). Obtaining exercise/PA is rated as an important reason for attending a tournament by many golf spectators. Spectating at a golf tournament can provide HEPA. 82.9% of spectators achieved the recommended daily step count while spectating. Further research directly assessing whether spectating may constitute a ‘teachable moment’, for increasing physical activity beyond the tournament itself, is merited. PMID:28761718

  15. The Effect of Parental Involvement on Children's Physical Activity.

    PubMed

    Rebold, Michael J; Lepp, Andrew; Kobak, Mallory S; McDaniel, John; Barkley, Jacob E

    2016-03-01

    To assess the amount, intensity, enjoyment, and preference of children's physical activity in a controlled gymnasium setting under 3 experimental, social conditions: alone, with a parent watching, and with a parent participating. Children (n = 10 girls, 10 boys), 3-6 years old, along with 1 parent (n = 17 mothers, 3 fathers) per child participated in each social condition on separate days for 30 minutes in which they could choose from a variety of physical and/or sedentary activities. A greater number of accelerometer counts (P ≤ .02) were accumulated during the parent participating (109,523 ± 32,155 counts) condition than the alone (67,938 ± 37,857 counts) and parent watching (85,624 ± 44,985 counts) conditions. Counts during parent watching were also greater (P = .01) than alone. More time (P ≤ .008) was allocated to sedentary activities during the alone (16.2 ± 9.6 minutes) condition than parent watching (9.6 ± 9.3 minutes) and parent participating (3.8 ± 5.1 minutes). Children liked (P ≤ .02) the parent participating (9.9 ± 0.45 cm) condition more than alone (8.0 ± 2.72 cm) and parent watching (8.7 ± 1.52 cm). A greater (P < .001) proportion of children identified the parent participating (80%) as their preferred condition over either the parent watching (10%) or alone (10%) conditions. Parental participation during physical activity (or at minimum direct supervision) may be an important component in the development of physical activity environments intended to maximize physical activity behavior in children. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Leukocyte changes across menstruation, ovulation, and mid-luteal phase and association with sex hormone variation.

    PubMed

    Nowak, Judyta; Borkowska, Barbara; Pawlowski, Boguslaw

    2016-09-10

    Total leukocyte count (white blood cells-WBC) and the count of each subpopulation vary across the menstrual cycle, but results of studies examining the time and direction of these changes are inconsistent and methodologically flawed. Besides, no previous study focused on leukocyte count on the day of ovulation. Blood samples were obtained from 37 healthy and regularly cycling women aged 19.8-36.1 years. Samples were taken three times: during menstruation (M), ovulation (O), and in the mid-luteal phase (ML). WBC, neutrophils, lymphocytes, mixed cells, progesterone (P,) and estradiol (E) were measured in each of the three target phases of the cycle. Compared to menstruation, WBC (P = 0.002) and neutrophils (P < 0.001) increased around ovulation and remained stable in the mid-luteal phase, whereas lymphocyte and mixed cell counts did not change throughout the menstrual cycle. There were some correlations of sex hormone variation with leukocyte changes between M and O (positive for E and WBC, negative for P and WBC and for P and neutrophil count; P < 0.05), but not between O and ML. Peripheral leukocyte changes taking place in the second half of the cycle are already observable on the day of ovulation and they are associated with sex hormone variation. We speculate that these changes may lead to increased immune protection against pathogens at a time when fertilization and implantation typically occur. Am. J. Hum. Biol. 28:721-728, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  17. Comparison of epifluorescent viable bacterial count methods

    NASA Technical Reports Server (NTRS)

    Rodgers, E. B.; Huff, T. L.

    1992-01-01

    Two methods, the 2-(4-Iodophenyl) 3-(4-nitrophenyl) 5-phenyltetrazolium chloride (INT) method and the direct viable count (DVC), were tested and compared for their efficiency for the determination of the viability of bacterial populations. Use of the INT method results in the formation of a dark spot within each respiring cell. The DVC method results in elongation or swelling of growing cells that are rendered incapable of cell division. Although both methods are subjective and can result in false positive results, the DVC method is best suited to analysis of waters in which the number of different types of organisms present in the same sample is assumed to be small, such as processed waters. The advantages and disadvantages of each method are discussed.

  18. Quantitative dermatoglyphic asymmetry: a comparative study between schizophrenic patients and control groups of West Bengal, India.

    PubMed

    Karmakar, B; Sengupta, M

    2012-01-01

    Quantitative Fluctuating (FA) and Directional asymmetry (DA) of dermatoglyphics on digito-palmar complex were analyzed in a group of 111 patients (males: 61, females: 50) with schizophrenia (SZ), and compared to an ethnically matched phenotypically healthy control (males: 60, females: 60) through MANOVA, ANOVA and canonical Discriminant analyses. With few exceptions, asymmetries are higher among patients, and this is more prominent in FA than DA. Statistically significant differences were observed between patient and control groups, especially in males. In both sexes, FA of combined dermatoglyphic traits (e.g. total finger ridge count, total palmar pattern ridge count) are found to be a strong discriminator between the two groups with a correct classification of over 83% probability.

  19. Three-dimensional reconstruction of glycosomes in trypanosomatids of the genus Phytomonas.

    PubMed

    Attias, M; de Souza, W

    1995-02-01

    Computer aided three dimensional (3-D) reconstruction of cells from two isolates of protozoa of the genus Phytomonas, trypanosomatids found in plants, were made from 0.3 microm thick sections, imaged on a Zeiss 902 electron microscope with a energy filter for in ellastically scattered electrons, in order to obtain information about glycosomal shape diversity. Direct counts of peroxisomes (glycosomes) from Phytomonas sp. from Chamaesyce thymifolia indicated that there were fewer glycosomes per cell than the simple count of ultrathin section profiles would suggest and that these organelles could be long and branched. On the other hand, the stacked glycosomes observed in the isolate from Euphorbia characias were small individual structures and no connection was seen between them.

  20. Real-time computational photon-counting LiDAR

    NASA Astrophysics Data System (ADS)

    Edgar, Matthew; Johnson, Steven; Phillips, David; Padgett, Miles

    2018-03-01

    The availability of compact, low-cost, and high-speed MEMS-based spatial light modulators has generated widespread interest in alternative sampling strategies for imaging systems utilizing single-pixel detectors. The development of compressed sensing schemes for real-time computational imaging may have promising commercial applications for high-performance detectors, where the availability of focal plane arrays is expensive or otherwise limited. We discuss the research and development of a prototype light detection and ranging (LiDAR) system via direct time of flight, which utilizes a single high-sensitivity photon-counting detector and fast-timing electronics to recover millimeter accuracy three-dimensional images in real time. The development of low-cost real time computational LiDAR systems could have importance for applications in security, defense, and autonomous vehicles.

  1. Counting of oligomers in sequences generated by markov chains for DNA motif discovery.

    PubMed

    Shan, Gao; Zheng, Wei-Mou

    2009-02-01

    By means of the technique of the imbedded Markov chain, an efficient algorithm is proposed to exactly calculate first, second moments of word counts and the probability for a word to occur at least once in random texts generated by a Markov chain. A generating function is introduced directly from the imbedded Markov chain to derive asymptotic approximations for the problem. Two Z-scores, one based on the number of sequences with hits and the other on the total number of word hits in a set of sequences, are examined for discovery of motifs on a set of promoter sequences extracted from A. thaliana genome. Source code is available at http://www.itp.ac.cn/zheng/oligo.c.

  2. Marginalized zero-inflated Poisson models with missing covariates.

    PubMed

    Benecha, Habtamu K; Preisser, John S; Divaris, Kimon; Herring, Amy H; Das, Kalyan

    2018-05-11

    Unlike zero-inflated Poisson regression, marginalized zero-inflated Poisson (MZIP) models for counts with excess zeros provide estimates with direct interpretations for the overall effects of covariates on the marginal mean. In the presence of missing covariates, MZIP and many other count data models are ordinarily fitted using complete case analysis methods due to lack of appropriate statistical methods and software. This article presents an estimation method for MZIP models with missing covariates. The method, which is applicable to other missing data problems, is illustrated and compared with complete case analysis by using simulations and dental data on the caries preventive effects of a school-based fluoride mouthrinse program. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Detection and counting of a submicrometer particle in liquid flow by self-mixing microchip Yb:YAG laser velocimetry.

    PubMed

    Ohtomo, Takayuki; Sudo, Seiichi; Otsuka, Kenju

    2016-09-20

    We observed intermittent modulation by scattered light from a single submicrometer particle moving in the flow channel using a self-mixing microchip Yb:YAG laser Doppler velocimeter (LDV) under lateral beam access. The Doppler-shift frequency chirping (i.e., velocity change) was identified in accordance with a particle passage through the beam focus. Single particle counting, which obeys the Poisson distribution, was performed successfully over a long period of time. The experimental results have been reproduced by a numerical simulation. The LDV signal was increased over 20 dB for a 202-nm particle without chirping by collinear beam access with the laser beam axis aligned along the flow direction.

  4. Instrumentation for laser physics and spectroscopy using 32-bit microcontrollers with an Android tablet interface

    NASA Astrophysics Data System (ADS)

    Eyler, E. E.

    2013-10-01

    Several high-performance lab instruments suitable for manual assembly have been developed using low-pin-count 32-bit microcontrollers that communicate with an Android tablet via a USB interface. A single Android tablet app accommodates multiple interface needs by uploading parameter lists and graphical data from the microcontrollers, which are themselves programmed with easily modified C code. The hardware design of the instruments emphasizes low chip counts and is highly modular, relying on small "daughter boards" for special functions such as USB power management, waveform generation, and phase-sensitive signal detection. In one example, a daughter board provides a complete waveform generator and direct digital synthesizer that fits on a 1.5 in. × 0.8 in. circuit card.

  5. Nuclear emulsion measurements of the astronauts' radiation exposures on Skylab missions 2, 3, and 4

    NASA Technical Reports Server (NTRS)

    Schaefer, H. J.; Sullivan, J. J.

    1975-01-01

    On the Skylab missions, Ilford G.5 and K.2 emulsions were flown as part of passive dosimeter packs carried by the astronauts on their wrists. Due to the long mission times, latent image fading and track crowing imposed limitations on a quantitative track and grain count analysis. For Skylab 2, the complete proton energy spectrum was determined within reasonable error limits. A combined mission dose equivalent of 2,490 millirems from protons, tissue stars and neutrons was measured on Skylab 2. A stationary emulsion stack, kept in a film vault drawer on the same mission, displayed a highly structured directional distribution of the fluence of low-energy protons (enders) reflecting the local shield distribution. On the 59 and 84-day mission 3 and 4, G.5 emulsions had to be cut on the microtom to 5-7 microns for microscopic examination. Even so, the short track segments in such thin layers precluded a statistically reliable grain count analysis. However, the K.2 emulsions still allowed accurate proton ender counts without special provisions.

  6. C$sup 12$(n,p) B$sup 12$ CROSS SECTION FOR 14.9- TO 17.5-MEV NEUTRONS

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Kreger, W.E.; Kern, B.D.

    1958-09-23

    The cross section for the C/sup 12/(n,p)B/sup 12/ reaction has been measured for 14.9- to 17.5-Mev nuetrons. The neutrons were obtained from the T(d,n)He/sup 4/ reaction and their flux density was determined by counting the recoil alpha particles or by counting the neutrons directly with a Li/sup 6/I(Eu) scintillation counter. A cylindrical plastic scintillator 5 inches in diameter and 3 inches in length served as the carbon-containing target and permitted the counting of the B/sup 12/ decay beta rays in nine consecutive 7-msec intervals during the beam-off period or a pulsed neutron beam cycle. The cross section rises from slightlymore » above the reaction threshold of 13.6-Mev to a value of 29.09 plus or minus 4.36 millibarns at 17.5 Mev. The B/sup 12/ beta decay half life has been redetermined as 18.87 plus or minus 0.50 milliseconds. (auth)« less

  7. DOE Office of Scientific and Technical Information (OSTI.GOV)

    Aab, A.; Abreu, P.; Aglietta, M.

    Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), ismore » proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.« less

  8. Hierarchical models of animal abundance and occurrence

    USGS Publications Warehouse

    Royle, J. Andrew; Dorazio, R.M.

    2006-01-01

    Much of animal ecology is devoted to studies of abundance and occurrence of species, based on surveys of spatially referenced sample units. These surveys frequently yield sparse counts that are contaminated by imperfect detection, making direct inference about abundance or occurrence based on observational data infeasible. This article describes a flexible hierarchical modeling framework for estimation and inference about animal abundance and occurrence from survey data that are subject to imperfect detection. Within this framework, we specify models of abundance and detectability of animals at the level of the local populations defined by the sample units. Information at the level of the local population is aggregated by specifying models that describe variation in abundance and detection among sites. We describe likelihood-based and Bayesian methods for estimation and inference under the resulting hierarchical model. We provide two examples of the application of hierarchical models to animal survey data, the first based on removal counts of stream fish and the second based on avian quadrat counts. For both examples, we provide a Bayesian analysis of the models using the software WinBUGS.

  9. A paraeducator glove for counting disabled-child behaviors that incorporates a Bluetooth Low Energy wireless link to a smart phone.

    PubMed

    Luan, Shiwei; Gude, Dana; Prakash, Punit; Warren, Steve

    2014-01-01

    Behavior tracking with severely disabled children can be a challenge, since dealing directly with a child's behavior is more immediately pressing than the need to record an event for tracking purposes. By the time a paraeducator (`para') is able to break away and record events, behavior counts can be forgotten. This paper presents a paraeducator glove design that can help to track behaviors with minimal distraction by allowing a paraeducator to touch their thumb to one of their other four fingers, where each finger represents a different behavior. Count data are packaged by a microcontroller board on the glove and then sent wirelessly to a smart phone via a Bluetooth Low Energy (BLE) link. A customized BLE profile was designed for this application to promote real-time recording. These data can be forwarded to a database for further analysis. This para glove design addresses basic needs of a wearable device that employs BLE, including local data collection, BLE data transmission, and remote data recording. More functional sensors can be added to this platform to support other wearable scenarios.

  10. Detection of microbial concentration in ice-cream using the impedance technique.

    PubMed

    Grossi, M; Lanzoni, M; Pompei, A; Lazzarini, R; Matteuzzi, D; Riccò, B

    2008-06-15

    The detection of microbial concentration, essential for safe and high quality food products, is traditionally made with the plate count technique, that is reliable, but also slow and not easily realized in the automatic form, as required for direct use in industrial machines. To this purpose, the method based on impedance measurements represents an attractive alternative since it can produce results in about 10h, instead of the 24-48h needed by standard plate counts and can be easily realized in automatic form. In this paper such a method has been experimentally studied in the case of ice-cream products. In particular, all main ice-cream compositions of real interest have been considered and no nutrient media has been used to dilute the samples. A measurement set-up has been realized using benchtop instruments for impedance measurements on samples whose bacteria concentration was independently measured by means of standard plate counts. The obtained results clearly indicate that impedance measurement represents a feasible and reliable technique to detect total microbial concentration in ice-cream, suitable to be implemented as an embedded system for industrial machines.

  11. Counted Sb donors in Si quantum dots

    NASA Astrophysics Data System (ADS)

    Singh, Meenakshi; Pacheco, Jose; Bielejec, Edward; Perry, Daniel; Ten Eyck, Gregory; Bishop, Nathaniel; Wendt, Joel; Luhman, Dwight; Carroll, Malcolm; Lilly, Michael

    2015-03-01

    Deterministic control over the location and number of donors is critical for donor spin qubits in semiconductor based quantum computing. We have developed techniques using a focused ion beam and a diode detector integrated next to a silicon MOS single electron transistor to gain such control. With the diode detector operating in linear mode, the numbers of ions implanted have been counted and single ion implants have been detected. Poisson statistics in the number of ions implanted have been observed. Transport measurements performed on samples with counted number of implants have been performed and regular coulomb blockade and charge offsets observed. The capacitances to various gates are found to be in agreement with QCAD simulations for an electrostatically defined dot. This work was performed, in part, at the Center for Integrated Nanotechnologies, a U.S. DOE Office of Basic Energy Sciences user facility. The work was supported by Sandia National Laboratories Directed Research and Development Program. Sandia National Laboratories is a multi-program laboratory operated by Sandia Corporation, a Lockheed-Martin Company, for the U. S. Department of Energy under Contract No. DE-AC04-94AL85000.

  12. Haematology and serum chemistry of Pyrenean chamois (Rupicapra pyrenaica) naturally infected with a border disease virus.

    PubMed

    Fernández-Sirera, L; Mentaberre, G; López-Olvera, J R; Cuenca, R; Lavín, S; Marco, I

    2011-06-01

    In 2005 and 2006 an outbreak of disease associated with border disease virus (BDV) infection caused high mortality in the Pyrenean chamois (Rupicapra pyrenaica) in the Catalan Pyrenees (NE Spain). The aim of this study was to determine values for different haematological and serum biochemical analytes in 32 free-ranging Pyrenean chamois affected by the disease and to compare them with those obtained from healthy chamois. In the affected chamois red blood cell counts, haemoglobin concentrations, packed cell volumes, mean corpuscular volumes and lymphocyte counts were all lower, while the neutrophil and platelet counts were higher. Glucose, lactate, triglycerides, creatinine, total protein concentrations and alkaline phosphatase activity were also lower, in contrast to the concentrations of total bilirubin, urea and aspartate aminotransferase activity, which were higher. Most of the observed changes could be associated with cachexia and inflammation in the affected chamois. Lymphopenia could be directly related to the BDV, which would lead to immunosuppression and explain the high rate of secondary infection observed in these animals. Copyright © 2010 Elsevier Ltd. All rights reserved.

  13. Superconducting analog-to-digital converter with a triple-junction reversible flip-flop bidirectional counter

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Lee, G.S.

    1993-07-13

    A high-performance superconducting analog-to-digital converter is described, comprising: a bidirectional binary counter having n stages of triple-junction reversible flip-flops connected together in a cascade arrangement from the least significant bit (LSB) to the most significant bit (MSB) where n is the number of bits of the digital output, each triple-junction reversible flip-flop including first, second and third shunted Josephson tunnel junctions and a superconducting inductor connected in a bridge circuit, the Josephson junctions and the inductor forming upper and lower portions of the flip-flop, each reversible flip-flop being a bistable logic circuit in which the direction of the circulating currentmore » determines the state of the circuit; and means for applying an analog input current to the bidirectional counter; wherein the bidirectional counter algebraically counts incremental changes in the analog input current, increasing the binary count for positive incremental changes in the analog current and decreasing the binary count for negative incremental changes in the current, and wherein the counter does not require a gate bias, thus minimizing power dissipation.« less

  14. Prediction of Mental Health Services Use One Year After Regular Referral to Specialized Care Versus Referral to Stepped Collaborative Care.

    PubMed

    van Orden, Mirjam; Leone, Stephanie; Haffmans, Judith; Spinhoven, Philip; Hoencamp, Erik

    2017-04-01

    Referral to collaborative mental health care within the primary care setting is a service concept that has shown to be as effective as direct referral to specialized mental health care for patients with common mental disorders. Additionally it is more efficient in terms of lower mental health services use. This post-hoc analysis examines if treatment intensity during 1-year of follow-up can be predicted prospectively by baseline characteristics. With multilevel multivariate regression analyses baseline characteristics were examined as potential predictors of visit counts. Results showed that only the enabling factors service concept and referral delay for treatment had a significant association with mental health visit counts, when outcome was dichotomized in five or more visits. Inclusion of the outcome variable as a count variable confirmed the predictive value of service concept and referral delay, but added marital status as a significant predictor. Overall, enabling factors (service concept and referral delay) seem to be important and dominant predictors of mental health services use.

  15. A Microbial Community in Sediments Beneath the Western Antarctic Ice Sheet, Ice Stream C (Kamb)

    NASA Astrophysics Data System (ADS)

    Skidmore, M.; Han, S.; Foo, W.; Bui, D.; Lanoil, B.

    2004-12-01

    In 2000, an ice-drilling project focusing on the "sticky spot" of Ice Stream C recovered cores of sub-glacial sediments from beneath the Western Antarctic Ice Sheet. We have characterized several chemical and microbiological parameters of the sole intact sediment core. Pore waters extracted from these sediments were brackish and some were supersaturated with respect to calcite. Ion chromatography demonstrated the presence of several organic acids at low, but detectable, levels in the pore water. DAPI direct cell counts were approximately 107 cells g-1. Aerobic viable plate counts were much lower than direct cell counts; however, they were two orders of magnitude higher on plates incubated at low temperature (4 ° C; 3.63 x 105 CFU ml-1) than at higher temperatures (ca. 22° C; 1.5 x 103 CFU ml-1); no colonies were detected on plates incubated anaerobically at either temperature. 16S rDNA clone library analysis indicates extremely limited bacterial diversity in these samples: six phylogenetic clades were detected. The three dominant bacterial phylogenetic clades in the clone libraries (252 clones total) were most closely related to Thiobacillus thioparus (180 clones), Polaromonas vacuolata (34 clones), and Gallionella ferruginea (35 clones) and their relatives; one clone each represented the other three phylogenetic clades (most closely related to Ralstonia pickettii, Lysobacter antibioticus, and Xylella fastidiosa, respectively). These sequences match closely with sequences previously obtained from other subglacial environments in Alaska, Ellesmere Island, Canada and New Zealand. Implications of this microbial community to subglacial chemistry and microbial biogeography will be discussed.

  16. Consequences count: against absolutism at the end of life.

    PubMed

    Snelling, Paul C

    2004-05-01

    There has been a considerable amount of debate in the nursing literature about euthanasia, and especially the distinctions between acts and omissions, and killing and letting die. These distinctions are required by opponents of euthanasia to justify allowing some cases of passive euthanasia while forbidding all cases of active euthanasia. This paper adds to the debate by arguing that the position that absolutely forbids euthanasia is theoretically inconsistent. The paper first considers the place of moral theory in analysing moral problems, within the framework of the principles of biomedical ethics. It is argued that despite a moral pluralism that operates in many areas, the legal status of euthanasia is based upon an absolute deontological position against deliberate killing, which cannot be overridden by appeals to favourable consequences. In order that certain forms of passive euthanasia can be allowed, this position allows distinctions within three pairs of concepts--acts and omissions, killing and letting die, and ordinary and extraordinary means. A further method of justifying certain actions near the end of life is the doctrine of double effect. These paired concepts and the doctrine of double effect are analysed with special reference to their consequences. The application of the doctrine of double effect and the three distinctions relies on consideration of their consequences, allowing in practice what in theory is denied. This is important because it weakens the absolute case against euthanasia, which disallows any direct consequentialist appeal. If consequences count in the application of the doctrine and the distinctions, then they should also count directly prior to their application. This strengthens the argument for active euthanasia in certain cases.

  17. Influence of contrast agent dose and ultrasound exposure on cardiomyocyte injury induced by myocardial contrast echocardiography in rats.

    PubMed

    Miller, Douglas L; Li, Peng; Dou, Chunyan; Gordon, David; Edwards, Chris A; Armstrong, William F

    2005-10-01

    To detect specific cardiomyocyte injury induced by myocardial contrast material-enhanced echocardiography (ie, myocardial contrast echocardiography) in rats and to ascertain the influences of contrast material dose and ultrasound exposure on this injury. All animal procedures were approved by the university committee for the use and care of animals. Myocardial contrast echocardiography with 1:4 electrocardiographic (ECG) triggering was performed at 1.5 MHz in 61 anesthetized rats. Evans blue (EB) dye was injected as the vital stain for cardiomyocyte injury. At the start of myocardial contrast echocardiography, which lasted 10 minutes, perflutren lipid microsphere-based contrast material was infused through the tail vein for 5 minutes. Premature heartbeats were counted from the ECG record. The numbers of EB-stained cells counted on sections of heart specimens obtained 24 hours after myocardial contrast echocardiography and then either fresh frozen or embedded in paraffin were determined by using fluorescence microscopy. Results were compared statistically by using t tests and Mann-Whitney rank sum tests. EB-stained cells were concentrated in the anterior region of the myocardium. In the paraffin-embedded specimens, EB-stained cells were often accompanied by but largely separate from areas of inflammatory cell infiltration. At end-systolic triggering with a 50 microL/kg dose of microsphere contrast material, the EB-stained cell count increased with increasing peak rarefactional pressure amplitude, with significantly increased cell counts at 1.6 MPa (P < .02) and 2.0 MPa (P < .005) relative to the cell counts at sham myocardial contrast echocardiography. Premature heartbeats had a similar exposure-response relationship; however, number of premature heartbeats and EB-stained cell count did not appear to be directly related (coefficient of determination r2 = 0.03). The EB-stained cell counts at end-diastolic triggering were not significantly different from those at end-systolic triggering (P > .1). EB-stained cell counts increased with increasing contrast material dose, from 10 to 50 microL/kg, at 2.0 MPa. Cardiomyocyte injury was induced by the interaction of ultrasound pulses with contrast agent microbubbles during myocardial contrast echocardiography in rats, and the numbers of injured cells increased with increasing contrast agent dose and ultrasound exposure. RSNA, 2005

  18. The Impact of Different CD4 Cell-Count Monitoring and Switching Strategies on Mortality in HIV-Infected African Adults on Antiretroviral Therapy: An Application of Dynamic Marginal Structural Models

    PubMed Central

    Ford, Deborah; Robins, James M.; Petersen, Maya L.; Gibb, Diana M.; Gilks, Charles F.; Mugyenyi, Peter; Grosskurth, Heiner; Hakim, James; Katabira, Elly; Babiker, Abdel G.; Walker, A. Sarah

    2015-01-01

    In Africa, antiretroviral therapy (ART) is delivered with limited laboratory monitoring, often none. In 2003–2004, investigators in the Development of Antiretroviral Therapy in Africa (DART) Trial randomized persons initiating ART in Uganda and Zimbabwe to either laboratory and clinical monitoring (LCM) or clinically driven monitoring (CDM). CD4 cell counts were measured every 12 weeks in both groups but were only returned to treating clinicians for management in the LCM group. Follow-up continued through 2008. In observational analyses, dynamic marginal structural models on pooled randomized groups were used to estimate survival under different monitoring-frequency and clinical/immunological switching strategies. Assumptions included no direct effect of randomized group on mortality or confounders and no unmeasured confounders which influenced treatment switch and mortality or treatment switch and time-dependent covariates. After 48 weeks of first-line ART, 2,946 individuals contributed 11,351 person-years of follow-up, 625 switches, and 179 deaths. The estimated survival probability after a further 240 weeks for post-48-week switch at the first CD4 cell count less than 100 cells/mm3 or non-Candida World Health Organization stage 4 event (with CD4 count <250) was 0.96 (95% confidence interval (CI): 0.94, 0.97) with 12-weekly CD4 testing, 0.96 (95% CI: 0.95, 0.97) with 24-weekly CD4 testing, 0.95 (95% CI: 0.93, 0.96) with a single CD4 test at 48 weeks (baseline), and 0.92 (95% CI: 0.91, 0.94) with no CD4 testing. Comparing randomized groups by 48-week CD4 count, the mortality risk associated with CDM versus LCM was greater in persons with CD4 counts of <100 (hazard ratio = 2.4, 95% CI: 1.3, 4.3) than in those with CD4 counts of ≥100 (hazard ratio = 1.1, 95% CI: 0.8, 1.7; interaction P = 0.04). These findings support a benefit from identifying patients immunologically failing first-line ART at 48 weeks. PMID:26316598

  19. Examining the validity of the ActivPAL monitor in measuring posture and ambulatory movement in children.

    PubMed

    Aminian, Saeideh; Hinckson, Erica A

    2012-10-02

    Decreasing sedentary activities that involve prolonged sitting may be an important strategy to reduce obesity and other physical and psychosocial health problems in children. The first step to understanding the effect of sedentary activities on children's health is to objectively assess these activities with a valid measurement tool. To examine the validity of the ActivPAL monitor in measuring sitting/lying, standing, and walking time, transition counts and step counts in children in a laboratory setting. Twenty five healthy elementary school children (age 9.9 ± 0.3 years; BMI 18.2 ± 1.9; mean ± SD) were randomly recruited across the Auckland region, New Zealand. Children were fitted with ActivPAL monitors and observed during simulated free-living activities involving sitting/lying, standing and walking, followed by treadmill and over-ground activities at various speeds (slow, normal, fast) against video observation (criterion measure). The ActivPAL sit-to-stand and stand-to-sit transition counts and steps were also compared with video data. The accuracy of step counts measured by the ActivPAL was also compared against the New Lifestyles NL-2000 and the Yamax Digi-Walker SW-200 pedometers. We observed a perfect correlation between the ActivPAL monitor in time spent sitting/lying, standing, and walking in simulated free-living activities with direct observation. Correlations between the ActivPAL and video observation in total numbers of sit-to-stand and stand-to-sit transitions were high (r = 0.99 ± 0.01). Unlike pedometers, the ActivPAL did not misclassify fidgeting as steps taken. Strong correlations (r = 0.88-1.00) between ActivPAL step counts and video observation in both treadmill and over-ground slow and normal walking were also observed. During treadmill and over-ground fast walking and running, the correlations were low (r = 0.21-0.46). The ActivPAL monitor is a valid measurement tool for assessing time spent sitting/lying, standing, and walking, sit-to-stand and stand-to-sit transition counts and step counts in slow and normal walking. The device did not measure accurately steps taken during treadmill and over-ground fast walking and running in children.

  20. Validity of Activity Monitor Step Detection Is Related to Movement Patterns.

    PubMed

    Hickey, Amanda; John, Dinesh; Sasaki, Jeffer E; Mavilia, Marianna; Freedson, Patty

    2016-02-01

    There is a need to examine step-counting accuracy of activity monitors during different types of movements. The purpose of this study was to compare activity monitor and manually counted steps during treadmill and simulated free-living activities and to compare the activity monitor steps to the StepWatch (SW) in a natural setting. Fifteen participants performed laboratory-based treadmill (2.4, 4.8, 7.2 and 9.7 km/h) and simulated free-living activities (eg, cleaning room) while wearing an activPAL, Omron HJ720-ITC, Yamax Digi- Walker SW-200, 2 ActiGraph GT3Xs (1 in "low-frequency extension" [AGLFE] and 1 in "normal-frequency" mode), an ActiGraph 7164, and a SW. Participants also wore monitors for 1-day in their free-living environment. Linear mixed models identified differences between activity monitor steps and the criterion in the laboratory/free-living settings. Most monitors performed poorly during treadmill walking at 2.4 km/h. Cleaning a room had the largest errors of all simulated free-living activities. The accuracy was highest for forward/rhythmic movements for all monitors. In the free-living environment, the AGLFE had the largest discrepancy with the SW. This study highlights the need to verify step-counting accuracy of activity monitors with activities that include different movement types/directions. This is important to understand the origin of errors in step-counting during free-living conditions.

  1. Automatic Detection of Pitching and Throwing Events in Baseball With Inertial Measurement Sensors.

    PubMed

    Murray, Nick B; Black, Georgia M; Whiteley, Rod J; Gahan, Peter; Cole, Michael H; Utting, Andy; Gabbett, Tim J

    2017-04-01

    Throwing loads are known to be closely related to injury risk. However, for logistic reasons, typically only pitchers have their throws counted, and then only during innings. Accordingly, all other throws made are not counted, so estimates of throws made by players may be inaccurately recorded and underreported. A potential solution to this is the use of wearable microtechnology to automatically detect, quantify, and report pitch counts in baseball. This study investigated the accuracy of detection of baseball pitching and throwing in both practice and competition using a commercially available wearable microtechnology unit. Seventeen elite youth baseball players (mean ± SD age 16.5 ± 0.8 y, height 184.1 ± 5.5 cm, mass 78.3 ± 7.7 kg) participated in this study. Participants performed pitching, fielding, and throwing during practice and competition while wearing a microtechnology unit. Sensitivity and specificity of a pitching and throwing algorithm were determined by comparing automatic measures (ie, microtechnology unit) with direct measures (ie, manually recorded pitching counts). The pitching and throwing algorithm was sensitive during both practice (100%) and competition (100%). Specificity was poorer during both practice (79.8%) and competition (74.4%). These findings demonstrate that the microtechnology unit is sensitive to detect pitching and throwing events, but further development of the pitching algorithm is required to accurately and consistently quantify throwing loads using microtechnology.

  2. The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon.

    PubMed

    Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Ozcan; Sahin, Mahmut

    2014-09-01

    The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Patients' demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow.

  3. Costs of detection bias in index-based population monitoring

    USGS Publications Warehouse

    Moore, C.T.; Kendall, W.L.

    2004-01-01

    Managers of wildlife populations commonly rely on indirect, count-based measures of the population in making decisions regarding conservation, harvest, or control. The main appeal in the use of such counts is their low material expense compared to methods that directly measure the population. However, their correct use rests on the rarely-tested but often-assumed premise that they proportionately reflect population size, i.e., that they constitute a population index. This study investigates forest management for the endangered Red-cockaded Woodpecker (Picoides borealis) and the Wood Thrush (Hylocichla mustelina) at the Piedmont National Wildlife Refuge in central Georgia, U.S.A. Optimal decision policies for a joint species objective were derived for two alternative models of Wood Thrush population dynamics. Policies were simulated under scenarios of unbiasedness, consistent negative bias, and habitat-dependent negative bias in observed Wood Thrush densities. Differences in simulation outcomes between biased and unbiased detection scenarios indicated the expected loss in resource objectives (here, forest habitat and birds) through decision-making based on biased population counts. Given the models and objective function used in our analysis, expected losses were as great as 11%, a degree of loss perhaps not trivial for applications such as endangered species management. Our analysis demonstrates that costs of uncertainty about the relationship between the population and its observation can be measured in units of the resource, costs which may offset apparent savings achieved by collecting uncorrected population counts.

  4. Photon counting detector for the personal radiography inspection system "SIBSCAN"

    NASA Astrophysics Data System (ADS)

    Babichev, E. A.; Baru, S. E.; Grigoriev, D. N.; Leonov, V. V.; Oleynikov, V. P.; Porosev, V. V.; Savinov, G. A.

    2017-02-01

    X-ray detectors operating in the energy integrating mode are successfully used in many different applications. Nevertheless the direct photon counting detectors, having the superior parameters in comparison with the integrating ones, are rarely used yet. One of the reasons for this is the low value of the electrical signal generated by a detected photon. Silicon photomultiplier (SiPM) based scintillation counters have a high detection efficiency, high electronic gain and compact dimensions. This makes them a very attractive candidate to replace routinely used detectors in many fields. More than 10 years ago the digital scanning radiography system based on multistrip ionization chamber (MIC) was suggested at Budker Institute of Nuclear Physics. The detector demonstrates excellent radiation resistance and parameter stability after 5 year operations and an imaging of up to 1000 persons per day. Currently, the installations operate at several Russian airports and at subway stations in some cities. At the present time we design a new detector operating in the photon counting mode, having superior parameters than the gas one, based on scintillator - SiPM assemblies. This detector has close to zero noise, higher quantum efficiency and a count rate capability of more than 5 MHz per channel (20% losses), which leads to better image quality and improved detection capability. The suggested detector technology could be expanded to medical applications.

  5. A direct electron detector for time-resolved MeV electron microscopy

    DOE PAGES

    Vecchione, T.; Denes, P.; Jobe, R. K.; ...

    2017-03-15

    The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here in this paper, we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μm spatial resolution and less than 20 analogue-to-digital converter count RMS pixelmore » noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.« less

  6. A direct electron detector for time-resolved MeV electron microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vecchione, T.; Denes, P.; Jobe, R. K.

    The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μmμm spatial resolution and less than 20 analogue-to-digital converter count RMS pixel noise. The uniquemore » capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.« less

  7. A direct electron detector for time-resolved MeV electron microscopy

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Vecchione, T.; Denes, P.; Jobe, R. K.

    The introduction of direct electron detectors enabled the structural biology revolution of cryogenic electron microscopy. Direct electron detectors are now expected to have a similarly dramatic impact on time-resolved MeV electron microscopy, particularly by enabling both spatial and temporal jitter correction. Here in this paper, we report on the commissioning of a direct electron detector for time-resolved MeV electron microscopy. The direct electron detector demonstrated MeV single electron sensitivity and is capable of recording megapixel images at 180 Hz. The detector has a 15-bit dynamic range, better than 30-μm spatial resolution and less than 20 analogue-to-digital converter count RMS pixelmore » noise. The unique capabilities of the direct electron detector and the data analysis required to take advantage of these capabilities are presented. The technical challenges associated with generating and processing large amounts of data are also discussed.« less

  8. Medication adherence assessment in a clinical trial with centralized follow-up and direct-to-patient drug shipments.

    PubMed

    Warren, Stuart R; Raisch, Dennis W; Campbell, Heather M; Guarino, Peter D; Kaufman, James S; Petrokaitis, Elizabeth; Goldfarb, David S; Gaziano, J Michael; Jamison, Rex L

    2013-01-01

    Assessment of adherence to study medications is a common challenge in clinical research. Counting unused study medication is the predominant method by which adherence is assessed in outpatient clinical trials but it has limitations that include questionable validity and burdens on research personnel. To compare capsule counts, patient questionnaire responses, and plasma drug levels as methods of determining adherence in a clinical trial that had 2056 participants and used centralized drug distribution and patient follow-up. Capsule counts from study medication bottles returned by participants and responses to questions regarding adherence during quarterly telephone interviews were averaged and compared. Both measures were compared to plasma drug levels obtained at the 3-month study visit of patients in the treatment group. Counts and questionnaire responses were converted to adherence rates (doses taken divided by days elapsed) and were categorized by stringent (≥85.7%) and liberal (≥71.4%) definitions. We calculated the prevalence-adjusted bias-adjusted kappa to assess agreement between the two measures. Using a pre-paid mailer, participants returned 76.0% of study medication bottles to the central pharmacy. Both capsule counts and questionnaire responses were available for 65.8% of participants and were used to assess adherence. Capsule counts identified more patients who were under-adherent (18.8% by the stringent definition and 7.5% by the liberal definition) than self-reports did (10.4% by the stringent definition and 2.1% by the liberal definition). The prevalence-adjusted bias-adjusted kappa was 0.58 (stringent) and 0.83 (liberal), indicating fair and very good agreement, respectively. Both measures were also in agreement with plasma drug levels determined at the 3-month visit (capsule counts: p = 0.005 for the stringent and p = 0.003 for the liberal definition; questionnaire: p = 0.002 for both adherence definitions). Inconsistent bottle returns and incomplete notations of medication start and stop dates resulted in missing data but exploratory missing data analyses showed no reason to believe that the missing data resulted in systematic bias. Depending upon the definition of adherence, there was fair to very good agreement between questionnaire results and capsule counts among returned study bottles, confirmed by plasma drug levels. We conclude that a self-report of medication adherence is potentially comparable to capsule counts as a method of assessing adherence in a clinical trial, if a relatively low adherence threshold is acceptable, but adherence should be confirmed by other measures if a high adherence threshold is required.

  9. Column-integrated aerosol optical properties of coarse- and fine-mode particles over the Pearl River Delta region in China.

    PubMed

    Mai, B; Deng, X; Xia, X; Che, H; Guo, J; Liu, X; Zhu, J; Ling, C

    2018-05-01

    The sun-photometer data from 2011 to 2013 at Panyu site (Panyu) and from 2007 to 2013 at Dongguan site (Dg) in the Pearl River Delta region, were used for the retrieving of the aerosol optical depth (AOD), single scattering albedo (SSA), Ångström exponent (AE) and volume size distribution of coarse- and fine-mode particles. The coarse-mode particles presented low AOD (ranging from 0.05±0.03 to 0.08±0.05) but a strong absorption property (SSA ranged from 0.70±0.03 to 0.90±0.02) for the wavelengths between 440 and 1020nm. However, these coarse particles accounted for <10% of the total particles. The AOD of fine particles (AODf) was over 3 times as large as that of coarse particles (AODc). The fine particles SSA (SSAf) generally decreased as a function of wavelength, and the relatively lower SSAf value in summer was likely to be due to the stronger solar radiation and higher temperature. More than 70% of the aerosols at Panyu site were dominated by fine-mode absorbing particles, whereas about 70% of the particles at Dg site were attributed to fine-mode scattering particles. The differences of the aerosol optical properties between the two sites are likely associated with local emissions of the light-absorbing carbonaceous aerosols and the scattering aerosols (e.g., sulfate and nitrate particles) caused by the gas-phase oxidation of gaseous precursors (e.g., SO 2 and NO 2 ). The size distribution exhibited bimodal structures in which the accumulation mode was predominant. The fine-mode volume showed positive dependence on AOD (500nm), and the growth of peak value of the fine-mode volume was higher than that of the coarse volume. Both the AOD and SSA increased with increasing relative humidity (RH), while the AE decreased with increasing RH. These correlations imply that the aerosol properties are greatly modified by condensation growth. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. A Survey of Telephone Inquiries: Case Study and Operational Impact in an Academic Library Reference Department.

    ERIC Educational Resources Information Center

    Allen, Frank R.; Smith, Rita H.

    1993-01-01

    Describes a survey that was conducted at the University of Tennessee at Knoxville library to count and categorize the types of questions coming into the reference department from telephone calls. Informational and directional calls are examined, implications for staffing are considered, and queuing theory is applied. (seven references) (LRW)

  11. An Embodiment Perspective on Number-Space Mapping in 3.5-year-old Dutch Children

    ERIC Educational Resources Information Center

    Noordende, Jaccoline E.; Volman, M(Chiel). J. M.; Leseman, Paul P. M.; Kroesbergen, Evelyn H.

    2017-01-01

    Previous research suggests that block adding, subtracting and counting direction are early forms of number-space mapping. In this study, an embodiment perspective on these skills was taken. Embodiment theory assumes that cognition emerges through sensory-motor interaction with the environment. In line with this assumption, it was investigated if…

  12. Magnetic field hourly averages from the Rome-GSFC experiment aboard Helios 1 and Helio 2

    NASA Technical Reports Server (NTRS)

    Mariani, F.; Ness, N. F.; Bavassano, B.; Bruno, R.; Buccellato, R.; Burlaga, L. F.; Cantarano, S.; Scearce, C. S.; Terenzi, R.; Villante, U.

    1987-01-01

    Plots of all the hourly averages computed from the solar magnetic field measurements obtained during the mission are given separately for Helios 1 and Helios 2. The magnitude and the direction of the averaged field are plotted versus the number of solar rotations as seen from Helios, counted from launch.

  13. Fission meter

    DOEpatents

    Rowland, Mark S [Alamo, CA; Snyderman, Neal J [Berkeley, CA

    2012-04-10

    A neutron detector system for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source.

  14. 42 CFR 413.79 - Direct GME payments: Determination of the weighted number of FTE residents.

    Code of Federal Regulations, 2010 CFR

    2010-10-01

    ... the initial residency period for a resident in an approved child neurology program is the period of... approved preventive medicine residency or fellowship program also may be counted as a full FTE resident for... in geriatric medicine, accredited by the appropriate approving body listed in § 415.152 of this...

  15. Three-dimension imaging lidar

    NASA Technical Reports Server (NTRS)

    Degnan, John J. (Inventor)

    2007-01-01

    This invention is directed to a 3-dimensional imaging lidar, which utilizes modest power kHz rate lasers, array detectors, photon-counting multi-channel timing receivers, and dual wedge optical scanners with transmitter point-ahead correction to provide contiguous high spatial resolution mapping of surface features including ground, water, man-made objects, vegetation and submerged surfaces from an aircraft or a spacecraft.

  16. Building on "Red Dirt" Perspectives: What Counts as Important for Remote Education?

    ERIC Educational Resources Information Center

    Guenther, John; Disbray, Samantha; Osborne, Sam

    2015-01-01

    The Remote Education Systems (RES) project within the Cooperative Research Centre for Remote Economic Participation (CRC-REP) has, over the last four years, gathered and analysed qualitative data directly from over 230 remote education stakeholders and from more than 700 others through surveys. The research was designed to answer four questions:…

  17. Travelling Concepts in National Curriculum Policy-Making: The Example of Competencies

    ERIC Educational Resources Information Center

    Nordin, Andreas; Sundberg, Daniel

    2016-01-01

    In this paper we will address the impact of Europeanisation on national curriculum reforms with empirical reference to the Swedish compulsory school, and based on the concept of competence discuss the question of transnational curriculum convergence. The main interest is directed towards how the answers to the question of what counts as knowledge…

  18. Poultry litter environment selects for the development of antibiotic resistance (AR) in Salmonella Heidelberg via conjugative IncX plasmids

    USDA-ARS?s Scientific Manuscript database

    The fitness of S. Heidelberg in poultry litter (PL) was determined following growth preconditioning in either Brain Heart Infusion (BHI) broth or poultry litter extracts (PLE, a centrifuged and filter sterilized PL slurry). Isolates were monitored by direct culture count for up to 9 days. The concen...

  19. "The Dilemma That Still Counts": Basic Writing at a Political Crossroads.

    ERIC Educational Resources Information Center

    Harrington, Susanmarie; Adler-Kassner, Linda

    1998-01-01

    Reviews definitions of basic writers and basic writing over the last 20 years. Argues that basic writers are not defined only in terms of institutional convenience. Offers future directions for basic writing research, suggesting that to learn more about basic writers, researchers must return to studies of error informed by basic writing's rich…

  20. ChromAIX2: A large area, high count-rate energy-resolving photon counting ASIC for a Spectral CT Prototype

    NASA Astrophysics Data System (ADS)

    Steadman, Roger; Herrmann, Christoph; Livne, Amir

    2017-08-01

    Spectral CT based on energy-resolving photon counting detectors is expected to deliver additional diagnostic value at a lower dose than current state-of-the-art CT [1]. The capability of simultaneously providing a number of spectrally distinct measurements not only allows distinguishing between photo-electric and Compton interactions but also discriminating contrast agents that exhibit a K-edge discontinuity in the absorption spectrum, referred to as K-edge Imaging [2]. Such detectors are based on direct converting sensors (e.g. CdTe or CdZnTe) and high-rate photon counting electronics. To support the development of Spectral CT and show the feasibility of obtaining rates exceeding 10 Mcps/pixel (Poissonian observed count-rate), the ChromAIX ASIC has been previously reported showing 13.5 Mcps/pixel (150 Mcps/mm2 incident) [3]. The ChromAIX has been improved to offer the possibility of a large area coverage detector, and increased overall performance. The new ASIC is called ChromAIX2, and delivers count-rates exceeding 15 Mcps/pixel with an rms-noise performance of approximately 260 e-. It has an isotropic pixel pitch of 500 μm in an array of 22×32 pixels and is tile-able on three of its sides. The pixel topology consists of a two stage amplifier (CSA and Shaper) and a number of test features allowing to thoroughly characterize the ASIC without a sensor. A total of 5 independent thresholds are also available within each pixel, allowing to acquire 5 spectrally distinct measurements simultaneously. The ASIC also incorporates a baseline restorer to eliminate excess currents induced by the sensor (e.g. dark current and low frequency drifts) which would otherwise cause an energy estimation error. In this paper we report on the inherent electrical performance of the ChromAXI2 as well as measurements obtained with CZT (CdZnTe)/CdTe sensors and X-rays and radioactive sources.

  1. Reconstructing grassland fire history using sedimentary charcoal: Considering count, size and shape.

    PubMed

    Leys, Berangere A; Commerford, Julie L; McLauchlan, Kendra K

    2017-01-01

    Fire is a key Earth system process, with 80% of annual fire activity taking place in grassland areas. However, past fire regimes in grassland systems have been difficult to quantify due to challenges in interpreting the charcoal signal in depositional environments. To improve reconstructions of grassland fire regimes, it is essential to assess two key traits: (1) charcoal count, and (2) charcoal shape. In this study, we quantified the number of charcoal pieces in 51 sediment samples of ponds in the Great Plains and tested its relevance as a proxy for the fire regime by examining 13 potential factors influencing charcoal count, including various fire regime components (e.g. the fire frequency, the area burned, and the fire season), vegetation cover and pollen assemblages, and climate variables. We also quantified the width to length (W:L) ratio of charcoal particles, to assess its utility as a proxy of fuel types in grassland environments by direct comparison with vegetation cover and pollen assemblages. Our first conclusion is that charcoal particles produced by grassland fires are smaller than those produced by forest fires. Thus, a mesh size of 120μm as used in forested environments is too large for grassland ecosystems. We recommend counting all charcoal particles over 60μm in grasslands and mixed grass-forest environments to increase the number of samples with useful data. Second, a W:L ratio of 0.5 or smaller appears to be an indicator for fuel types, when vegetation surrounding the site is before composed of at least 40% grassland vegetation. Third, the area burned within 1060m of the depositional environments explained both the count and the area of charcoal particles. Therefore, changes in charcoal count or charcoal area through time indicate a change in area burned. The fire regimes of grassland systems, including both human and climatic influences on fire behavior, can be characterized by long-term charcoal records.

  2. Reconstructing grassland fire history using sedimentary charcoal: Considering count, size and shape

    PubMed Central

    Leys, Berangere A.; Commerford, Julie L.; McLauchlan, Kendra K.

    2017-01-01

    Fire is a key Earth system process, with 80% of annual fire activity taking place in grassland areas. However, past fire regimes in grassland systems have been difficult to quantify due to challenges in interpreting the charcoal signal in depositional environments. To improve reconstructions of grassland fire regimes, it is essential to assess two key traits: (1) charcoal count, and (2) charcoal shape. In this study, we quantified the number of charcoal pieces in 51 sediment samples of ponds in the Great Plains and tested its relevance as a proxy for the fire regime by examining 13 potential factors influencing charcoal count, including various fire regime components (e.g. the fire frequency, the area burned, and the fire season), vegetation cover and pollen assemblages, and climate variables. We also quantified the width to length (W:L) ratio of charcoal particles, to assess its utility as a proxy of fuel types in grassland environments by direct comparison with vegetation cover and pollen assemblages. Our first conclusion is that charcoal particles produced by grassland fires are smaller than those produced by forest fires. Thus, a mesh size of 120μm as used in forested environments is too large for grassland ecosystems. We recommend counting all charcoal particles over 60μm in grasslands and mixed grass-forest environments to increase the number of samples with useful data. Second, a W:L ratio of 0.5 or smaller appears to be an indicator for fuel types, when vegetation surrounding the site is before composed of at least 40% grassland vegetation. Third, the area burned within 1060m of the depositional environments explained both the count and the area of charcoal particles. Therefore, changes in charcoal count or charcoal area through time indicate a change in area burned. The fire regimes of grassland systems, including both human and climatic influences on fire behavior, can be characterized by long-term charcoal records. PMID:28448597

  3. Determination of mammalian cell counts, cell size and cell health using the Moxi Z mini automated cell counter.

    PubMed

    Dittami, Gregory M; Sethi, Manju; Rabbitt, Richard D; Ayliffe, H Edward

    2012-06-21

    Particle and cell counting is used for a variety of applications including routine cell culture, hematological analysis, and industrial controls(1-5). A critical breakthrough in cell/particle counting technologies was the development of the Coulter technique by Wallace Coulter over 50 years ago. The technique involves the application of an electric field across a micron-sized aperture and hydrodynamically focusing single particles through the aperture. The resulting occlusion of the aperture by the particles yields a measurable change in electric impedance that can be directly and precisely correlated to cell size/volume. The recognition of the approach as the benchmark in cell/particle counting stems from the extraordinary precision and accuracy of its particle sizing and counts, particularly as compared to manual and imaging based technologies (accuracies on the order of 98% for Coulter counters versus 75-80% for manual and vision-based systems). This can be attributed to the fact that, unlike imaging-based approaches to cell counting, the Coulter Technique makes a true three-dimensional (3-D) measurement of cells/particles which dramatically reduces count interference from debris and clustering by calculating precise volumetric information about the cells/particles. Overall this provides a means for enumerating and sizing cells in a more accurate, less tedious, less time-consuming, and less subjective means than other counting techniques(6). Despite the prominence of the Coulter technique in cell counting, its widespread use in routine biological studies has been prohibitive due to the cost and size of traditional instruments. Although a less expensive Coulter-based instrument has been produced, it has limitations as compared to its more expensive counterparts in the correction for "coincidence events" in which two or more cells pass through the aperture and are measured simultaneously. Another limitation with existing Coulter technologies is the lack of metrics on the overall health of cell samples. Consequently, additional techniques must often be used in conjunction with Coulter counting to assess cell viability. This extends experimental setup time and cost since the traditional methods of viability assessment require cell staining and/or use of expensive and cumbersome equipment such as a flow cytometer. The Moxi Z mini automated cell counter, described here, is an ultra-small benchtop instrument that combines the accuracy of the Coulter Principle with a thin-film sensor technology to enable precise sizing and counting of particles ranging from 3-25 microns, depending on the cell counting cassette used. The M type cassette can be used to count particles from with average diameters of 4 - 25 microns (dynamic range 2 - 34 microns), and the Type S cassette can be used to count particles with and average diameter of 3 - 20 microns (dynamic range 2 - 26 microns). Since the system uses a volumetric measurement method, the 4-25 microns corresponds to a cell volume range of 34 - 8,180 fL and the 3 - 20 microns corresponds to a cell volume range of 14 - 4200 fL, which is relevant when non-spherical particles are being measured. To perform mammalian cell counts using the Moxi Z, the cells to be counted are first diluted with ORFLO or similar diluent. A cell counting cassette is inserted into the instrument, and the sample is loaded into the port of the cassette. Thousands of cells are pulled, single-file through a "Cell Sensing Zone" (CSZ) in the thin-film membrane over 8-15 seconds. Following the run, the instrument uses proprietary curve-fitting in conjunction with a proprietary software algorithm to provide coincidence event correction along with an assessment of overall culture health by determining the ratio of the number of cells in the population of interest to the total number of particles. The total particle counts include shrunken and broken down dead cells, as well as other debris and contaminants. The results are presented in histogram format with an automatic curve fit, with gates that can be adjusted manually as needed. Ultimately, the Moxi Z enables counting with a precision and accuracy comparable to a Coulter Z2, the current gold standard, while providing additional culture health information. Furthermore it achieves these results in less time, with a smaller footprint, with significantly easier operation and maintenance, and at a fraction of the cost of comparable technologies.

  4. High resolution micro-CT of low attenuating organic materials using large area photon-counting detector

    NASA Astrophysics Data System (ADS)

    Kumpová, I.; Vavřík, D.; Fíla, T.; Koudelka, P.; Jandejsek, I.; Jakůbek, J.; Kytýř, D.; Zlámal, P.; Vopálenský, M.; Gantar, A.

    2016-02-01

    To overcome certain limitations of contemporary materials used for bone tissue engineering, such as inflammatory response after implantation, a whole new class of materials based on polysaccharide compounds is being developed. Here, nanoparticulate bioactive glass reinforced gelan-gum (GG-BAG) has recently been proposed for the production of bone scaffolds. This material offers promising biocompatibility properties, including bioactivity and biodegradability, with the possibility of producing scaffolds with directly controlled microgeometry. However, to utilize such a scaffold with application-optimized properties, large sets of complex numerical simulations using the real microgeometry of the material have to be carried out during the development process. Because the GG-BAG is a material with intrinsically very low attenuation to X-rays, its radiographical imaging, including tomographical scanning and reconstructions, with resolution required by numerical simulations might be a very challenging task. In this paper, we present a study on X-ray imaging of GG-BAG samples. High-resolution volumetric images of investigated specimens were generated on the basis of micro-CT measurements using a large area flat-panel detector and a large area photon-counting detector. The photon-counting detector was composed of a 010× 1 matrix of Timepix edgeless silicon pixelated detectors with tiling based on overlaying rows (i.e. assembled so that no gap is present between individual rows of detectors). We compare the results from both detectors with the scanning electron microscopy on selected slices in transversal plane. It has been shown that the photon counting detector can provide approx. 3× better resolution of the details in low-attenuating materials than the integrating flat panel detectors. We demonstrate that employment of a large area photon counting detector is a good choice for imaging of low attenuating materials with the resolution sufficient for numerical simulations.

  5. Replication capacity in relation to immunologic and virologic outcomes in HIV-1-infected treatment-naive subjects.

    PubMed

    Skowron, Gail; Spritzler, John G; Weidler, Jodi; Robbins, Gregory K; Johnson, Victoria A; Chan, Ellen S; Asmuth, David M; Gandhi, Rajesh T; Lie, Yolanda; Bates, Michael; Pollard, Richard B

    2009-03-01

    To evaluate the association between baseline (BL) replication capacity (RC) (RCBL) and immunologic/virologic parameters (at BL and after 48 weeks on therapy) in HIV-1-infected subjects initiating antiretroviral therapy. RCBL was determined using a modified Monogram PhenoSense HIV drug susceptibility assay on plasma HIV-1 from 321 treatment-naive subjects from AIDS Clinical Trials Group 384. Univariate and multivariable analyses were performed to determine the association of RCBL with BL and on-therapy virologic and immunologic outcomes. Higher RCBL was associated with lower baseline CD4 (CD4BL) (r = -0.23, P < 0.0001), higher baseline HIV-1 RNA (r = 0.25, P < 0.0001), higher CD4BL activation percent (r = 0.23, P < 0.0001), and lower CD4BL memory count (r = -0.21, P = 0.0002). In a multivariable model, week 48 CD4 increase (DeltaCD448) was associated with lower CD4BL memory count and higher CD4BL-naive percent (P = 0.004, P = 0.015, respectively). The interaction between CD4BL and RCBL was significant (P = 0.018), with a positive association between RCBL and DeltaCD448 in subjects with higher CD4BL and a negative association at lower absCD4BL. At baseline, higher RC was significantly associated with higher HIV-1 RNA, higher CD4 cell activation, lower CD4 cell count, and lower CD4 memory cell count. These factors may interact, directly or indirectly, to modify the extent to which CD4 recovery occurs in patients starting antiretroviral therapy at different CD4BL counts.

  6. Replication Capacity in Relation to Immunologic and Virologic Outcomes in HIV-1 infected, Treatment-Naïve Subjects

    PubMed Central

    Skowron, Gail; Spritzler, John G.; Weidler, Jodi; Robbins, Gregory K.; Johnson, Victoria A.; Chan, Ellen S.; Asmuth, David M.; Gandhi, Rajesh T.; Lie, Yolanda; Bates, Michael; Pollard, Richard B.

    2012-01-01

    Objectives To evaluate the association between baseline (BL) replication capacity (RC) [RCBL] and immunologic/virologic parameters (at BL and after 48 weeks on therapy) in HIV-1 infected subjects initiating antiretroviral therapy. Methods RCBL was determined using a modified Monogram PhenoSense HIV drug susceptibility assay on plasma HIV-1 from 321 treatment-naïve subjects from ACTG384. Univariate and multivariable analyses were performed to determine the association of RCBL with BL and on-therapy virologic and immunologic outcomes. Results Higher RCBL was associated with lower baseline CD4 (CD4BL) (r=−0.23, p<0.0001), higher baseline HIV-1 (RNABL) (r=0.25, p<0.0001), higher CD4BL activation percent (r=0.23, p<0.0001) and lower CD4BL memory count (r=−0.21, p=0.0002). In a multivariable model, week 48 CD4 increase (ΔCD448) was associated with lower CD4BL memory count and higher CD4BL naive percent (p=0.004, p=0.015, respectively). The interaction between CD4BL and RCBL was significant (p=0.018), with a positive association between RCBL and ΔCD448 in subjects with higher CD4BL, and a negative association at lower absCD4BL. Conclusions At baseline, higher RC was significantly associated with higher HIV-1 RNA, higher CD4 cell activation, lower CD4 cell count, and lower CD4 memory cell count. These factors may interact, directly or indirectly, to modify the extent to which CD4 recovery occurs in patients starting antiretroviral therapy at different baseline CD4 counts. PMID:19194319

  7. High resolution time interval meter

    DOEpatents

    Martin, A.D.

    1986-05-09

    Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.

  8. Indirect questioning method reveals hidden support for female genital cutting in South Central Ethiopia.

    PubMed

    Gibson, Mhairi A; Gurmu, Eshetu; Cobo, Beatriz; Rueda, María M; Scott, Isabel M

    2018-01-01

    Female genital cutting (FGC) has major implications for women's physical, sexual and psychological health, and eliminating the practice is a key target for public health policy-makers. To date one of the main barriers to achieving this has been an inability to infer privately-held views on FGC within communities where it is prevalent. As a sensitive (and often illegal) topic, people are anticipated to hide their true support for the practice when questioned directly. Here we use an indirect questioning method (unmatched count technique) to identify hidden support for FGC in a rural South Central Ethiopian community where the practice is common, but thought to be in decline. Employing a socio-demographic household survey of 1620 Arsi Oromo adults, which incorporated both direct and indirect direct response (unmatched count) techniques we compare directly-stated versus privately-held views in support of FGC, and individual variation in responses by age, gender and education and target female (daughters versus daughters-in-law). Both genders express low support for FGC when questioned directly, while indirect methods reveal substantially higher acceptance (of cutting both daughters and daughters-in-law). Educated adults (those who have attended school) are privately more supportive of the practice than they are prepared to admit openly to an interviewer, indicating that education may heighten secrecy rather than decrease support for FGC. Older individuals hold the strongest views in favour of FGC (particularly educated older males), but they are also more inclined to conceal their support for FGC when questioned directly. As these elders represent the most influential members of society, their hidden support for FGC may constitute a pivotal barrier to eliminating the practice in this community. Our results demonstrate the great potential for indirect questioning methods to advance knowledge and inform policy on culturally-sensitive topics like FGC; providing more reliable data and improving understanding of the "true" drivers of FGC.

  9. Finding, Serving, and Housing the Homeless: Using Collaborative Research to Prepare Social Work Students for Research and Practice

    ERIC Educational Resources Information Center

    Lane, Shannon R.; McClendon, Jennifer; Matthews, Natalie

    2017-01-01

    Social work plays a key role in engaging with clients and communities directly affected by housing insecurity and homelessness, and advocating for the right to safe and affordable housing. This article describes methodologies of the Point-in-Time Count and Homeless Management Information Systems and proposes strategies for integrating additional…

  10. Newark Kids Count 2008: A City Profile of Child Well-Being

    ERIC Educational Resources Information Center

    Association for Children of New Jersey, 2008

    2008-01-01

    Newark's image has begun to change in recent years. High-profile construction projects downtown and a boom in new housing have been among the visible signs of change. Improvements on measures of child and family well-being have added to the impression of the city moving in a positive direction. Child poverty rates fell in recent years. Incomes…

  11. Burn Treatment: Annual Research Progress Report.

    DTIC Science & Technology

    1975-06-30

    in addition to direct or indirect measurements of blood pressure. Central venous pressures are measured relatively frequently and, on occasion, a... Central venous pressure assessment. 5. EKG. 46 I 6. Sponge weighing. 7. Measurement of urine output during surgery. B. RESPIRATION 1. Counting of...start a central venous line prior to adminis- tration of vasopressors. The patient became progressively more hypo- tensive and bradycardiac, which

  12. Sampling western spruce budworm larvae by frequency of occurrence on lower crown branches.

    Treesearch

    R.R. Mason; R.C. Beckwith

    1990-01-01

    A sampling method was derived whereby budworm density can be estimated by the frequency of occurrence of larvae over a given threshold number instead of by direct counts on branch samples. The model used for converting frequencies to mean densities is appropriate for nonrandom as well as random distributions and, therefore, is applicable to all population densities of...

  13. Comparing the Effectiveness of Polymer Debriding Devices Using a Porcine Wound Biofilm Model.

    PubMed

    Wilkinson, Holly N; McBain, Andrew J; Stephenson, Christian; Hardman, Matthew J

    2016-11-01

    Objective: Debridement to remove necrotic and/or infected tissue and promote active healing remains a cornerstone of contemporary chronic wound management. While there has been a recent shift toward less invasive polymer-based debriding devices, their efficacy requires rigorous evaluation. Approach: This study was designed to directly compare monofilament debriding devices to traditional gauze using a wounded porcine skin biofilm model with standardized application parameters. Biofilm removal was determined using a surface viability assay, bacterial counts, histological assessment, and scanning electron microscopy (SEM). Results: Quantitative analysis revealed that monofilament debriding devices outperformed the standard gauze, resulting in up to 100-fold greater reduction in bacterial counts. Interestingly, histological and morphological analyses suggested that debridement not only removed bacteria, but also differentially disrupted the bacterially-derived extracellular polymeric substance. Finally, SEM of post-debridement monofilaments showed structural changes in attached bacteria, implying a negative impact on viability. Innovation: This is the first study to combine controlled and defined debridement application with a biologically relevant ex vivo biofilm model to directly compare monofilament debriding devices. Conclusion: These data support the use of monofilament debriding devices for the removal of established wound biofilms and suggest variable efficacy towards biofilms composed of different species of bacteria.

  14. Research and design on orthogonal diffraction grating-based 3D nanometer displacement sensor

    NASA Astrophysics Data System (ADS)

    Liu, Baoshuai; Yuan, Yibao; Yin, Zhehao

    2017-10-01

    This study concerns an orthogonal diffraction grating-based nanometer displacement sensor. In this study, we performed calculation of displacements in the XYZ directions. In the optical measured path part, we used a two-dimensional orthogonal motion grating and a two-dimensional orthogonal reference grating with the pitch of 0.5um to measure the displacement of XYZ in three directions by detecting ±1st diffraction fringes. The self-collimated structure of the grating greatly extended the Z-axis range. We also simulated the optical path of the sensor with ZEMAX software and verified the feasibility of the scheme. For signal subdivision and processing, we combined large number counting (completed grating line) with small number counting (digital subdivision), realizing high multiples of subdivision of grating interference signals. We used PC to process the interference fringes and greatly improved the processing speed. In the scheme, the theoretical multiples of subdivision could reach 1024 with 10-bit AD conversion, but the actual multiples of subdivision was limited by the quality of the grating interference signals. So we introduced an orthogonal compensation circuit and a filter circuit to improve the signal quality.

  15. Microbial Characterization of Qatari Barchan Sand Dunes

    PubMed Central

    Chatziefthimiou, Aspassia D.; Nguyen, Hanh; Richer, Renee; Louge, Michel; Sultan, Ali A.; Schloss, Patrick; Hay, Anthony G.

    2016-01-01

    This study represents the first characterization of sand microbiota in migrating barchan sand dunes. Bacterial communities were studied through direct counts and cultivation, as well as 16S rRNA gene and metagenomic sequence analysis to gain an understanding of microbial abundance, diversity, and potential metabolic capabilities. Direct on-grain cell counts gave an average of 5.3 ± 0.4 x 105 cells g-1 of sand. Cultured isolates (N = 64) selected for 16S rRNA gene sequencing belonged to the phyla Actinobacteria (58%), Firmicutes (27%) and Proteobacteria (15%). Deep-sequencing of 16S rRNA gene amplicons from 18 dunes demonstrated a high relative abundance of Proteobacteria, particularly enteric bacteria, and a dune-specific-pattern of bacterial community composition that correlated with dune size. Shotgun metagenome sequences of two representative dunes were analyzed and found to have similar relative bacterial abundance, though the relative abundances of eukaryotic, viral and enterobacterial sequences were greater in sand from the dune closer to a camel-pen. Functional analysis revealed patterns similar to those observed in desert soils; however, the increased relative abundance of genes encoding sporulation and dormancy are consistent with the dune microbiome being well-adapted to the exceptionally hyper-arid Qatari desert. PMID:27655399

  16. Efficacy of guided spiral drawing in the classification of Parkinson's Disease.

    PubMed

    Zham, Poonam; Arjunan, Sridhar; Raghav, Sanjay; Kumar, Dinesh Kant

    2017-10-11

    Change of handwriting can be an early marker for severity of Parkinson's disease but suffers from poor sensitivity and specificity due to inter-subject variations. This study has investigated the group-difference in the dynamic features during sketching of spiral between PD and control subjects with the aim of developing an accurate method for diagnosing PD patients. Dynamic handwriting features were computed for 206 specimens collected from 62 Subjects (31 Parkinson's and 31 Controls). These were analyzed based on the severity of the disease to determine group-difference. Spearman rank correlation coefficient was computed to evaluate the strength of association for the different features. Maximum area under ROC curve (AUC) using the dynamic features during different writing and spiral sketching tasks were in the range of 67 to 79 %. However, when angular features ( and ) and count of direction inversion during sketching of the spiral were used, AUC improved to 93.3%. Spearman correlation coefficient was highest for and . The angular features and count of direction inversion which can be obtained in real-time while sketching the Archimedean guided spiral on a digital tablet can be used for differentiating between Parkinson's and healthy cohort.

  17. Determination of microbial contamination of plastic cups for dairy products and utilization of electron beam treatment for sterilization.

    PubMed

    Tacker, M; Hametner, C; Wepner, B

    2002-01-01

    Packaging materials are often considered a critical control point in HACCP systems of food companies. Methods for the determination of the microbial contamination rate of plastic cups, especially for dairy products, must reliably detect single moulds, yeasts or coliforms. In this study, a comparison of a specially adapted coating method, impedance method, direct inoculation and membrane filter technique was carried out to determine contamination with yeasts, moulds, coliforms and total bacterial counts using the appropriate agar in each case. The coating method is recommended for determining yeasts, moulds and coliforms as it allows the localization of the microorganisms as well as the determination of single microorganisms. For total bacterial count, a direct inoculation technique is proposed. The employing of simple measures in the production and during transport of packaging materials, such as dust-prevention or tight sealing in polyethylene bags, heavily reduces microbial contamination rates of packaging material. To reduce contamination rates further, electron beam irradiation was applied: plastic cups sealed in polyethylene bags were treated with 4-5 kGy, a dose that already leads to sterile polystyrene and polypropylene cups without influencing mechanical characteristics of the packaging material.

  18. Wood-inhabiting fungal communities in woody debris of Norway spruce (Picea abies (L.) Karst.), as reflected by sporocarps, mycelial isolations and T-RFLP identification.

    PubMed

    Allmér, Johan; Vasiliauskas, Rimvis; Ihrmark, Katarina; Stenlid, Jan; Dahlberg, Anders

    2006-01-01

    Wood-inhabiting fungi play a key role in forest ecosystems and constitute an essential part of forest biodiversity. We therefore examined the composition and abundance of wood-inhabiting fungi by three methods: sporocarp counts, mycelial culturing and direct amplification of internal transcribed spacer terminal restriction fragment length polymorphism from wood combined with sequencing of reference rDNA. Seven-year-old slash piles left after a thinning were analyzed in a 50-year-old Norway spruce plantation. Fifty-eight fungal species were detected from the piled branches and treetops. More species were revealed by sporocarp counts and cultured mycelia than by direct amplification from wood. In principle, sporocarp monitoring may reveal all fruiting taxa, but it poorly reflects their relative abundance in the wood. In contrast, terminal restriction fragment length polymorphism will record the most frequent fungal taxa in the wood, but it may overlook uncommon taxa. Culturing mycelia from wood gives a bias towards species favoured by the cultural medium. The results demonstrate the advantage and the limitations of these methods to be considered in analyses of fungal communities in wood.

  19. Abstract knowledge versus direct experience in processing of binomial expressions

    PubMed Central

    Morgan, Emily; Levy, Roger

    2016-01-01

    We ask whether word order preferences for binomial expressions of the form A and B (e.g. bread and butter) are driven by abstract linguistic knowledge of ordering constraints referencing the semantic, phonological, and lexical properties of the constituent words, or by prior direct experience with the specific items in questions. Using forced-choice and self-paced reading tasks, we demonstrate that online processing of never-before-seen binomials is influenced by abstract knowledge of ordering constraints, which we estimate with a probabilistic model. In contrast, online processing of highly frequent binomials is primarily driven by direct experience, which we estimate from corpus frequency counts. We propose a trade-off wherein processing of novel expressions relies upon abstract knowledge, while reliance upon direct experience increases with increased exposure to an expression. Our findings support theories of language processing in which both compositional generation and direct, holistic reuse of multi-word expressions play crucial roles. PMID:27776281

  20. Measurement of effective detective quantum efficiency for a photon counting scanning mammography system and comparison with two flat panel full-field digital mammography systems

    NASA Astrophysics Data System (ADS)

    Wood, Tim J.; Moore, Craig S.; Saunderson, John R.; Beavis, Andrew W.

    2018-01-01

    Effective detective quantum efficiency (eDQE) describes the resolution and noise properties of an imaging system along with scatter and primary transmission, all measured under clinically appropriate conditions. Effective dose efficiency (eDE) is the eDQE normalised to mean glandular dose and has been proposed as a useful metric for the optimisation of clinical imaging systems. The aim of this study was to develop a methodology for measuring eDQE and eDE on a Philips microdose mammography (MDM) L30 photon counting scanning system, and to compare performance with two conventional flat panel systems. A custom made lead-blocker was manufactured to enable the accurate determination of dose measurements, and modulation transfer functions were determined free-in-air at heights of 2, 4 and 6 cm above the breast support platform. eDQE were calculated for a Philips MDM L30, Hologic Dimensions and Siemens Inspiration digital mammography system for 2, 4 and 6 cm thick poly(methyl methacrylate) (PMMA). The beam qualities (target/filter and kilovoltage) assessed were those selected by the automatic exposure control, and anti-scatter grids were used where available. Measurements of eDQE demonstrate significant differences in performance between the slit- and scan-directions for the photon counting imaging system. MTF has been shown to be the limiting factor in the scan-direction, which results in a rapid fall in eDQE at mid-to-high spatial frequencies. A comparison with two flat panel mammography systems demonstrates that this may limit image quality for small details, such as micro-calcifications, which correlates with a more conventional image quality assessment with the CDMAM phantom. eDE has shown the scanning photon counting system offers superior performance for low spatial frequencies, which will be important for the detection of large low contrast masses. Both eDQE and eDE are proposed as useful metrics that should enable optimisation of the Philips MDM L30.

  1. A double-observer method for reducing bias in faecal pellet surveys of forest ungulates

    USGS Publications Warehouse

    Jenkins, K.J.; Manly, B.F.J.

    2008-01-01

    1. Faecal surveys are used widely to study variations in abundance and distribution of forest-dwelling mammals when direct enumeration is not feasible. The utility of faecal indices of abundance is limited, however, by observational bias and variation in faecal disappearance rates that obscure their relationship to population size. We developed methods to reduce variability in faecal surveys and improve reliability of faecal indices. 2. We used double-observer transect sampling to estimate observational bias of faecal surveys of Roosevelt elk Cervus elaphus roosevelti and Columbian black-tailed deer Odocoileus hemionus columbianus in Olympic National Park, Washington, USA. We also modelled differences in counts of faecal groups obtained from paired cleared and uncleared transect segments as a means to adjust standing crop faecal counts for a standard accumulation interval and to reduce bias resulting from variable decay rates. 3. Estimated detection probabilities of faecal groups ranged from < 0.2-1.0 depending upon the observer, whether the faecal group was from elk or deer, faecal group size, distance of the faecal group from the sampling transect, ground vegetation cover, and the interaction between faecal group size and distance from the transect. 4. Models of plot-clearing effects indicated that standing crop counts of deer faecal groups required 34% reduction on flat terrain and 53% reduction on sloping terrain to represent faeces accumulated over a standard 100-day interval, whereas counts of elk faecal groups required 0% and 46% reductions on flat and sloping terrain, respectively. 5. Synthesis and applications. Double-observer transect sampling provides a cost-effective means of reducing observational bias and variation in faecal decay rates that obscure the interpretation of faecal indices of large mammal abundance. Given the variation we observed in observational bias of faecal surveys and persistence of faeces, we emphasize the need for future researchers to account for these comparatively manageable sources of bias before comparing faecal indices spatially or temporally. Double-observer sampling methods are readily adaptable to study variations in faecal indices of large mammals at the scale of the large forest reserve, natural area, or other forested regions when direct estimation of populations is problematic. ?? 2008 The Authors.

  2. Method and means for measuring the anisotropy of a plasma in a magnetic field

    DOEpatents

    Shohet, J.L.; Greene, D.G.S.

    1973-10-23

    Anisotropy is measured of a free-free-bremsstrahlungradiation-generating plasma in a magnetic field by collimating the free-free bremsstrahlung radiation in a direction normal to the magnetic field and scattering the collimated free- free bremsstrahlung radiation to resolve the radiation into its vector components in a plane parallel to the electric field of the bremsstrahlung radiation. The scattered vector components are counted at particular energy levels in a direction parallel to the magnetic field and also normal to the magnetic field of the plasma to provide a measure of anisotropy of the plasma. (Official Gazette)

  3. Effects of Agronomic Treatments on Structure and Function of Ammonia-Oxidizing Communities

    PubMed Central

    Phillips, Carol J.; Harris, Dave; Dollhopf, Sherry L.; Gross, Katherine L.; Prosser, James I.; Paul, Eldor A.

    2000-01-01

    The aim of this study was to determine the effects of different agricultural treatments and plant communities on the diversity of ammonia oxidizer populations in soil. Denaturing gradient gel electrophoresis (DGGE), coupled with specific oligonucleotide probing, was used to analyze 16S rRNA genes of ammonia oxidizers belonging to the β subgroup of the division Proteobacteria by use of DNA extracted from cultivated, successional, and native deciduous forest soils. Community profiles of the different soil types were compared with nitrification rates and most-probable-number (MPN) counts. Despite significant variation in measured nitrification rates among communities, there were no differences in the DGGE banding profiles of DNAs extracted from these soils. DGGE profiles of DNA extracted from samples of MPN incubations, cultivated at a range of ammonia concentrations, showed the presence of bands not amplified from directly extracted DNA. Nitrosomonas-like bands were seen in the MPN DNA but were not detected in the DNA extracted directly from soils. These bands were detected in some samples taken from MPN incubations carried out with medium containing 1,000 μg of NH4+-N ml−1, to the exclusion of bands detected in the native DNA. Cell concentrations of ammonia oxidizers determined by MPN counts were between 10- and 100-fold lower than those determined by competitive PCR (cPCR). Although no differences were seen in ammonia oxidizer MPN counts from the different soil treatments, cPCR revealed higher numbers in fertilized soils. The use of a combination of traditional and molecular methods to investigate the activities and compositions of ammonia oxidizers in soil demonstrates differences in fine-scale compositions among treatments that may be associated with changes in population size and function. PMID:11097922

  4. High-content image analysis (HCIA) assay has the highest correlation with direct counting cell suspension compared to the ATP, WST-8 and Alamar blue assays for measurement of cytotoxicity.

    PubMed

    Tahara, Haruna; Matsuda, Shun; Yamamoto, Yusuke; Yoshizawa, Hiroe; Fujita, Masaharu; Katsuoka, Yasuhiro; Kasahara, Toshihiko

    2017-11-01

    Various cytotoxicity assays measuring indicators such as enzyme activity, dye uptake, or cellular ATP content are often performed using 96-well microplates. However, recent reports show that cytotoxicity assays such as the ATP assay and MTS assay underestimate cytotoxicity when compounds such as anti-cancer drugs or mutagens induce cell hypertrophy whilst increasing intracellular ATP content. Therefore, we attempted to evaluate the reliability of a high-content image analysis (HCIA) assay to count cell number in a 96-well microplate automatically without using a cell-number indicator. We compared cytotoxicity results of 25 compounds obtained from ATP, WST-8, Alamar blue, and HCIA assays with those directly measured using an automatic cell counter, and repeating individual experiments thrice. The number of compounds showing low correlation in cell viability measured using cytotoxicity assays compared to automatic cell counting (r 2 <0.8, at least 2 of 3 experiments) were follows: ATP assay; 7; WST-8 assay, 2; Alamar blue assay, 3; HCIA cytotoxicity assay, 0. Compounds for which correlation was poor in 3 assays, except the HCIA assay, induced an increase in nuclear and cell size. However, correlation between cell viability measured by automatic cell counter and the HCIA assay was strong regardless of nuclear and cell size. Additionally, correlation coefficients between IC 50 values obtained from automatic cell counter and from cytotoxicity assays were as follows: ATP assay, 0.80; WST-8 assay, 0.84; Alamar blue assay, 0.84; and HCIA assay, 0.98. From the above, we showed that the HCIA cytotoxicity assay produces similar data to the automatic cell counter and is highly accurate in measuring cytotoxicity. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Lipid biomarker analysis for the quantitative analysis of airborne microorganisms

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Macnaughton, S.J.; Jenkins, T.L.; Cormier, M.R.

    1997-08-01

    There is an ever increasing concern regarding the presence of airborne microbial contaminants within indoor air environments. Exposure to such biocontaminants can give rise to large numbers of different health effects including infectious diseases, allergenic responses and respiratory problems, Biocontaminants typically round in indoor air environments include bacteria, fungi, algae, protozoa and dust mites. Mycotoxins, endotoxins, pollens and residues of organisms are also known to cause adverse health effects. A quantitative detection/identification technique independent of culturability that assays both culturable and non culturable biomass including endotoxin is critical in defining risks from indoor air biocontamination. Traditionally, methods employed for themore » monitoring of microorganism numbers in indoor air environments involve classical culture based techniques and/or direct microscopic counting. It has been repeatedly documented that viable microorganism counts only account for between 0.1-10% of the total community detectable by direct counting. The classic viable microbiologic approach doe`s not provide accurate estimates of microbial fragments or other indoor air components that can act as antigens and induce or potentiate allergic responses. Although bioaerosol samplers are designed to damage the microbes as little as possible, microbial stress has been shown to result from air sampling, aerosolization and microbial collection. Higher collection efficiency results in greater cell damage while less cell damage often results in lower collection efficiency. Filtration can collect particulates at almost 100% efficiency, but captured microorganisms may become dehydrated and damaged resulting in non-culturability, however, the lipid biomarker assays described herein do not rely on cell culture. Lipids are components that are universally distributed throughout cells providing a means to assess independent of culturability.« less

  6. MONICA: A Compact, Portable Dual Gamma Camera System for Mouse Whole-Body Imaging

    PubMed Central

    Xi, Wenze; Seidel, Jurgen; Karkareka, John W.; Pohida, Thomas J.; Milenic, Diane E.; Proffitt, James; Majewski, Stan; Weisenberger, Andrew G.; Green, Michael V.; Choyke, Peter L.

    2009-01-01

    Introduction We describe a compact, portable dual-gamma camera system (named “MONICA” for MObile Nuclear Imaging CAmeras) for visualizing and analyzing the whole-body biodistribution of putative diagnostic and therapeutic single photon emitting radiotracers in animals the size of mice. Methods Two identical, miniature pixelated NaI(Tl) gamma cameras were fabricated and installed “looking up” through the tabletop of a compact portable cart. Mice are placed directly on the tabletop for imaging. Camera imaging performance was evaluated with phantoms and field performance was evaluated in a weeklong In-111 imaging study performed in a mouse tumor xenograft model. Results Tc-99m performance measurements, using a photopeak energy window of 140 keV ± 10%, yielded the following results: spatial resolution (FWHM at 1-cm), 2.2-mm; sensitivity, 149 cps/MBq (5.5 cps/μCi); energy resolution (FWHM), 10.8%; count rate linearity (count rate vs. activity), r2 = 0.99 for 0–185 MBq (0–5 mCi) in the field-of-view (FOV); spatial uniformity, < 3% count rate variation across the FOV. Tumor and whole-body distributions of the In-111 agent were well visualized in all animals in 5-minute images acquired throughout the 168-hour study period. Conclusion Performance measurements indicate that MONICA is well suited to whole-body single photon mouse imaging. The field study suggests that inter-device communications and user-oriented interfaces included in the MONICA design facilitate use of the system in practice. We believe that MONICA may be particularly useful early in the (cancer) drug development cycle where basic whole-body biodistribution data can direct future development of the agent under study and where logistical factors, e.g. limited imaging space, portability, and, potentially, cost are important. PMID:20346864

  7. Effects of bacterial pollution caused by a strong typhoon event and the restoration of a recreational beach: Transitions of fecal bacterial counts and bacterial flora in beach sand.

    PubMed

    Suzuki, Yoshihiro; Teranishi, Kotaro; Matsuwaki, Tomonori; Nukazawa, Kei; Ogura, Yoshitoshi

    2018-05-28

    To determine the effects of bacteria pollution associated with a strong typhoon event and to assess the restoration of the normal bacterial flora, we used conventional filtration methods and nextgeneration sequencing of 16S rRNA genes to analyze the transition of fecal and total bacterial counts in water and core sand samples collected from a recreational beach. Immediately after the typhoon event, Escherichia coli counts increased to 82 CFU/100 g in the surface beach sand. E. coli was detected through the surface to sand 85-cm deep at the land side point (10-m land side from the high-water line). However, E. coli disappeared within a month from the land side point. The composition of the bacterial flora in the beach sand at the land point was directly influenced by the typhoon event. Pseudomonas was the most prevalent genus throughout the sand layers (0-102-cm deep) during the typhoon event. After 3 months, the population of Pseudomonas significantly decreased, and the predominant genus in the surface layer was Kaistobacter, although Pseudomonas was the major genus in the 17- to 85-cm layer. When the beach conditions stabilized, the number of pollutant Pseudomonas among the 10 most abundant genera decreased to lower than the limit of detection. The bacterial population of the sand was subsequently restored to the most populous pre-event orders at the land point. A land-side beach, where users directly contact the sand, was significantly affected by bacterial pollution caused by a strong typhoon event. We show here that the normal bacterial flora of the surface sand was restored within 1 month. Copyright © 2018 Elsevier B.V. All rights reserved.

  8. Quantitative comparison of the in situ microbial communities in different biomes

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    White, D.C.; Ringelberg, D.B.; Palmer, R.J.

    1995-12-31

    A system to define microbial communities in different biomes requires the application of non-traditional methodology. Classical microbiological methods have severe limitations for the analysis of environmental samples. Pure-culture isolation, biochemical testing, and/or enumeration by direct microscopic counting are not well suited for the estimation of total biomass or the assessment of community composition within environmental samples. Such methods provide little insight into the in situ phenotypic activity of the extant microbiota since these techniques are dependent on microbial growth and thus select against many environmental microorganisms which are non- culturable under a wide range of conditions. It has been repeatedlymore » documented in the literature that viable counts or direct counts of bacteria attached to sediment grains are difficult to quantitative and may grossly underestimate the extent of the existing community. The traditional tests provide little indication of the in situ nutritional status or for evidence of toxicity within the microbial community. A more recent development (MIDI Microbial Identification System), measure free and ester-linked fatty acids from isolated microorganisms. Bacterial isolates are identified by comparing their fatty acid profiles to the MIKI database which contains over 8000 entries. The application of the MIKI system to the analysis of environmental samples however, has significant drawbacks. The MIDI system was developed to identify clinical microorganisms and requires their isolation and culture on trypticase soy agar at 27{degrees}C. Since many isolates are unable to grow at these restrictive growth conditions, the system does not lend itself to identification of some environmental organisms. A more applicable methodology for environmental microbial analysis is based on the liquid extrication and separation of microbial lipids from environmental samples, followed by quantitative analysis using gas chromatography/« less

  9. Coliphage and indigenous phage in Mamala Bay, Oahu, Hawaii.

    PubMed

    Paul, J H; Rose, J B; Jiang, S C; London, P; Xhou, X; Kellogg, C

    1997-01-01

    Public concern over the discharge of primarily treated sewage by two offshore outfalls in Mamala Bay, Oahu, prompted a multidisciplinary study to determine the impact of such activities on the water quality in the bay and at adjacent recreational beaches. As part of this study, we determined the abundance of coliphage as an indicator of fecal pollution along with total viral direct counts and phages infective for Vibrio parahaemoltyicus 16 at stations in Mamala Bay in four quarterly samplings over 13 months. Coliphage (< 1 to 1.2 x 10(3)/liter) were found during each quarterly sampling along an offshore transect to the Sand Island waste treatment facility outfall. The nonpoint coastal stations (Pearl Harbor, Ala Wai Canal, and Ke'ehi Lagoon) had high levels of coliphage during the storm event sampling in February 1994 but much lower levels or none when sampled during dry weather. Coliphage were absent at all samplings at Waikiki Beach and at the control station off Diamond Head. Viral direct counts in eutrophic coastal stations (Pearl Harbor, Ke'ehi Lagoon, Ala Moana Beach, and Ala Wai canal) averaged 10(9)/liter, while counts at offshore stations ranged from 9 x 10(7) to 1 x 10(9) viruses/liter, values similar to those for other marine environments. Vibriophage were found mainly in eutrophic coastal environments (Ala Wai Canal, Pearl Harbor, and Ke'ehi Lagoon) and at the Sand Island Transect stations D1 and D2. The greatest abundance was found during the storm event (February 1994) sampling. These results suggest that the Sand Island outfall influenced the water quality of the immediate surrounding waters but had little effect on the quality of the recreational beaches. Nonpoint discharge sources appeared to be more important in the distribution of fecal indicators in the coastal zone.

  10. Risk assessment of false-positive quantitative real-time PCR results in food, due to detection of DNA originating from dead cells.

    PubMed

    Wolffs, Petra; Norling, Börje; Rådström, Peter

    2005-03-01

    Real-time PCR technology is increasingly used for detection and quantification of pathogens in food samples. A main disadvantage of nucleic acid detection is the inability to distinguish between signals originating from viable cells and DNA released from dead cells. In order to gain knowledge concerning risks of false-positive results due to detection of DNA originating from dead cells, quantitative PCR (qPCR) was used to investigate the degradation kinetics of free DNA in four types of meat samples. Results showed that the fastest degradation rate was observed (1 log unit per 0.5 h) in chicken homogenate, whereas the slowest rate was observed in pork rinse (1 log unit per 120.5 h). Overall results indicated that degradation occurred faster in chicken samples than in pork samples and faster at higher temperatures. Based on these results, it was concluded that, especially in pork samples, there is a risk of false-positive PCR results. This was confirmed in a quantitative study on cell death and signal persistence over a period of 28 days, employing three different methods, i.e. viable counts, direct qPCR, and finally floatation, a recently developed discontinuous density centrifugation method, followed by qPCR. Results showed that direct qPCR resulted in an overestimation of up to 10 times of the amount of cells in the samples compared to viable counts, due to detection of DNA from dead cells. However, after using floatation prior to qPCR, results resembled the viable count data. This indicates that by using of floatation as a sample treatment step prior to qPCR, the risk of false-positive PCR results due to detection of dead cells, can be minimized.

  11. The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon

    PubMed Central

    Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Özcan; Sahin, Mahmut

    2014-01-01

    Background and Objective: The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Methods: Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Results: Patients’ demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Conclusion: Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow. PMID:25225502

  12. Equivalency testing of TTC Tergitol 7 agar (ISO 9308-1:2000) with five culture media for the detection of E. coli in water samples in Greece.

    PubMed

    Mavridou, A; Smeti, E; Mandilara, G; Mandilara, G; Boufa, P; Vagiona-Arvanitidou, M; Vantarakis, A; Vassilandonopoulou, G; Pappa, O; Roussia, V; Tzouanopoulos, A; Livadara, M; Aisopou, I; Maraka, V; Nikolaou, E; Mandilara, G

    2010-01-01

    In this study ten laboratories in Greece compared the performance of reference method TTC Tergitol 7 Agar (with the additional test of beta-glucuronidase production) with five alternative methods, to detect E. coli in water, in line with European Water Directive recommendations. The samples were prepared by spiking drinking water with sewage effluent following a standard protocol. Chlorinated and non-chlorinated samples were used. The statistical analysis was based on the mean relative difference of confirmed counts and was performed in line with ISO 17994. The results showed that in total, three of the alternative methods (Chromocult Coliform agar, Membrane Lauryl Sulfate agar and Trypton Bilex-glucuronidase medium) were not different from TTC Tergitol 7 agar (TTC Tergitol 7 agar vs Chromocult Coliform agar, 294 samples, mean RD% 5.55; vs MLSA, 302 samples, mean RD% 1; vs TBX, 297 samples, mean RD% -2.78). The other two alternative methods (Membrane Faecal coliform medium and Colilert 18/ Quantitray) gave significantly higher counts than TTC Tergitol 7 agar (TTC Tergitol 7 agar vs MFc, 303 samples, mean RD% 8.81; vs Colilert-18/Quantitray, 76 samples, mean RD% 18.91). In other words, the alternative methods generated performance that was as reliable as, or even better than, the reference method. This study will help laboratories in Greece overcome culture and counting problems deriving from the EU reference method for E. coli counts in water samples.

  13. Circulating endothelial cells as marker of endothelial damage in male hypogonadism.

    PubMed

    Milardi, Domenico; Grande, Giuseppe; Giampietro, Antonella; Vendittelli, Francesca; Palumbo, Sara; Tartaglione, Linda; Marana, Riccardo; Pontecorvi, Alfredo; de Marinis, Laura; Zuppi, Cecilia; Capoluongo, Ettore

    2012-01-01

    Testosterone deficiency has become a frequently diagnosed condition in today's society affected by epidemic obesity, and is associated with cardiovascular risk. Recent studies have established the importance of altered vascular endothelium function in cardiovascular disease. The damage to the endothelium might also cause endothelial cell detachment, resulting in increased numbers of circulating endothelial cells (CEC) within the bloodstream. To evaluate whether hypogonadism could modify CEC count in peripheral bloodstream, we investigated peripheral blood CEC count using the CellSearch System, a semiautomatic method to accurately and reliably enumerate CECs, which are sorted based on a CD146(+), CD105(+), DAPI(+), CD45(-) phenotype, in a population of 20 patients with hypogonadism. The control group comprised 10 age- and sex-matched healthy participants. CEC count per milliliter was significantly increased in patients with hypogonadism vs the control group. In the group with hypogonadism, an inverse exponential correlation was present between testosterone levels and CEC count per milliliter. A direct linear correlation was present between waist circumference and CECs and between body mass index and CECs. The regression analysis showed that testosterone was the significant independent determinant of CECs. Our results underline that male hypogonadism is associated with endothelial dysfunction. The correlation between CEC and waist circumference underlines that visceral obesity may be synergically implicated in this regulation. Future studies are required to unveil the mechanisms involved in the pathogenesis of testosterone-induced endothelial disfunction, which may provide novel therapeutic targets to be incorporated in the management of hypogonadism.

  14. Hematologic reference intervals and age effect in European Strigiformes.

    PubMed

    Agusti Montolio, Susana; Molina López, Rafael; Cray, Carolyn; Lavín González, Santiago; Nicolás Francisco, Olga; Marco Sánchez, Ignasi; Casas-Díaz, Encarna; Cuenca Valera, Rafaela

    2017-09-01

    The clinical importance of hematologic testing in avian veterinary medicine is reflected in the increasing number of studies for the establishment of hematologic RIs of Strigiformes and other species. Age is an important physiologic factor in birds and the effect on hematology variable should be understood. The objective of this study was to determine baseline data of hematologic variables in 5 species of Iberian Strigiformes in different age classes. Nocturnal birds of prey were sampled at Wildlife Health Centers. Packed cell volume was determined by the microhematocrit centrifugation method, and RBC and WBC counts were determined using the direct hemocytometer count method with Natt and Herrick solution. Hemoglobin concentration was measured spectrophotometrically. The MCV, MCHC, and MHC were calculated using the standard formulas. The differential WBC count was performed by the routine microscopic evaluation of 200 cells on a blood smear manually stained with Wright stain. Thrombocyte blood count estimate was obtained from the blood film. No differences were observed between juveniles and adults for any variable evaluated in Tawny owl, Little owl, Scops owl, Long-eared owl, and Barn owl. In addition, PCV, RBC, and HGB of chicks were statistically significantly lower than in juveniles and adults, and total WBC was significantly higher in Tawny owl, Little owl, Scops owl, and Long-eared owl. Our findings provide evidence that laboratory data from chicks of Strigiformes are different compared to juveniles and adults; therefore, separate RIs were defined. © 2017 American Society for Veterinary Clinical Pathology.

  15. The Construct Validity of the CODA and Repeated Sprint Ability Tests in Football Referees.

    PubMed

    Riiser, Amund; Andersen, Vidar; Castagna, Carlo; Arne Pettersen, Svein; Saeterbakken, Atle; Froyd, Christian; Ylvisaker, Einar; Naess Kjosnes, Terje; Fusche Moe, Vegard

    2018-06-14

    As of 2017, the international football federation introduced the change of direction ability test (CODA) and the 5×30 m sprint test for assistant referees (ARs) and continued the 6×40 m sprint test for field referees (FRs) as mandatory tests. The aim of this study was to evaluate the association between performance in these tests and running performance during matches at the top level in Norway. The study included 9 FRs refereeing 21 matches and 19 ARs observed 53 times by a local positioning system at three stadiums during the 2016 season. Running performance during matches was assessed by high-intensity running (HIR) distance, HIR counts, acceleration distance, and acceleration counts. For the ARs, there was no association between the CODA test with high-intensity running or acceleration ( P >0.05). However, the 5×30 m sprint test was associated with HIR count during the entire match (E -12.9, 95% CI -25.4 to -0.4) and the 5-min period with the highest HIR count (E -2.02, 95% CI -3.55 to -0.49). For the FRs, the 6×40 m fitness test was not associated with running performance during matches ( P >0.05). In conclusion, performance in these tests had weak or no associations with accelerations or HIR in top Norwegian referees during match play. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Pretreatment with oleic acid accelerates the entrance into the mitotic cycle of EGF-stimulated fibroblasts.

    PubMed

    Zugaza, J L; Casabiell, X A; Bokser, L; Eiras, A; Beiras, A; Casanueva, F F

    1995-07-01

    We have previously demonstrated that pretreatment of several cell lines with cis-unsaturated fatty acids, like oleic acid, blocks epidermal growth factor (EGF)-induced early ionic signals, and in particular the [Ca2+]i rise. In the present work we show that this blockade does not alter EGF-stimulated cellular proliferation evaluated by direct cell counting, but induces a powerful enhancement in the pulsed thymidine incorporation assay. The lack of effect of oleic acid on EGF-stimulated cellular proliferation was confirmed by repeated cell counts, cumulative thymidine incorporation, and protein synthesis, but a clear synergistic effect between oleic acid and EGF was again obtained by means of time course experiments with pulsed thymidine. Combined flow cytometry analysis and cell counts at earlier times in EGF-stimulated cells showed that oleic acids accelerates the entrance of cells into the replicative cycle leading to an earlier cell division. Afterward, these oleic acid-pretreated cells became delayed by an unknown compensatory mechanism in such a way that at 48 h post-EGF, the cell count in control and oleic acid-pretreated cells was equal. In conclusion (a) oleic acid accelerates or enhances the EGF mitogenic action and (b) in the long term cells compensate the initial perturbation with respect to untreated cells. As a side observation, the widely employed pulsed thymidine incorporation method as a measure of cell division could be extremely misleading unless experimental conditions are well controlled.

  17. Influence of phosphate and disinfection on the composition of biofilms produced from drinking water, as measured by fluorescence in situ hybridization.

    PubMed

    Batté, M; Mathieu, L; Laurent, P; Prévost, M

    2003-12-01

    Biofilms were grown in annular reactors supplied with drinking water enriched with 235 microg C/L. Changes in the biofilms with ageing, disinfection, and phosphate treatment were monitored using fluorescence in situ hybridization. EUB338, BET42a, GAM42a, and ALF1b probes were used to target most bacteria and the alpha (alpha), beta (beta), and gamma (gamma) subclasses of Proteobacteria, respectively. The stability of biofilm composition was checked after the onset of colonization between T = 42 days and T = 113 days. From 56.0% to 75.9% of the cells detected through total direct counts with DAPI (4'-6-diamidino-2-phenylindole) were also detected with the EUB338 probe, which targets the 16S rRNA of most bacteria. Among these cells, 16.9%-24.7% were targeted with the BET42a probe, 1.8%-18.3% with the ALF1b probe, and <2.5% with the GAM42a probe. Phosphate treatment induced a significant enhancement to the proportion of gamma-Proteobacteria (detected with the GAM42a probe), a group that contains many health-related bacteria. Disinfection with monochloramine for 1 month or chlorine for 3 days induced a reduction in the percentage of DAPI-stained cells that hybridized with the EUB338 probe (as expressed by percentages of EUB338 counts/DAPI) and with any of the ALF1b, BET42a, and GAM42a probes. The percentage of cells detected by any of the three probes (ALF1b+BET42a+GAM42a) tended to decrease, and reached in total less than 30% of the EUB338-hybridized cells. Disinfection with chlorine for 7 days induced a reverse shift; an increase in the percentage of EUB338 counts targeted by any of these three probes was noted, which reached up to 87%. However, it should be noted that the global bacterial densities (heterotrophic plate counts and total direct counts) tended to decrease over the duration of the experiment. Therefore, those bacteria that could be considered to resist 7 days of chlorination constituted a small part of the initial biofilm community, up to the point at which the other bacterial groups were destroyed by chlorination. The results suggest that there were variations in the kinetics of inactivation by disinfectant, depending on the bacterial populations involved.

  18. Characterization of photon-counting multislit breast tomosynthesis.

    PubMed

    Berggren, Karl; Cederström, Björn; Lundqvist, Mats; Fredenberg, Erik

    2018-02-01

    It has been shown that breast tomosynthesis may improve sensitivity and specificity compared to two-dimensional mammography, resulting in increased detection-rate of cancers or lowered call-back rates. The purpose of this study is to characterize a spectral photon-counting multislit breast tomosynthesis system that is able to do single-scan spectral imaging with multiple collimated x-ray beams. The system differs in many aspects compared to conventional tomosynthesis using energy-integrating flat-panel detectors. The investigated system was a prototype consisting of a dual-threshold photon-counting detector with 21 collimated line detectors scanning across the compressed breast. A review of the system is done in terms of detector, acquisition geometry, and reconstruction methods. Three reconstruction methods were used, simple back-projection, filtered back-projection and an iterative algebraic reconstruction technique. The image quality was evaluated by measuring the modulation transfer-function (MTF), normalized noise-power spectrum, detective quantum-efficiency (DQE), and artifact spread-function (ASF) on reconstructed spectral tomosynthesis images for a total-energy bin (defined by a low-energy threshold calibrated to remove electronic noise) and for a high-energy bin (with a threshold calibrated to split the spectrum in roughly equal parts). Acquisition was performed using a 29 kVp W/Al x-ray spectrum at a 0.24 mGy exposure. The difference in MTF between the two energy bins was negligible, that is, there was no energy dependence on resolution. The MTF dropped to 50% at 1.5 lp/mm to 2.3 lp/mm in the scan direction and 2.4 lp/mm to 3.3 lp/mm in the slit direction, depending on the reconstruction method. The full width at half maximum of the ASF was found to range from 13.8 mm to 18.0 mm for the different reconstruction methods. The zero-frequency DQE of the system was found to be 0.72. The fraction of counts in the high-energy bin was measured to be 59% of the total detected spectrum. Scantimes ranged from 4 s to 16.5 s depending on voltage and current settings. The characterized system generates spectral tomosynthesis images with a dual-energy photon-counting detector. Measurements show a high DQE, enabling high image quality at a low dose, which is beneficial for low-dose applications such as screening. The single-scan spectral images open up for applications such as quantitative material decomposition and contrast-enhanced tomosynthesis. © 2017 American Association of Physicists in Medicine.

  19. Reduced sperm counts in guppies (Poecilia reticulata) following exposure to low levels of tributyltin and bisphenol A.

    PubMed Central

    Haubruge, E; Petit, F; Gage, M J

    2000-01-01

    There is increasing evidence that normal male reproductive function can be disrupted by exposure to pollutants in the environment that can exogenously mimic, antagonize or block sex-hormone function. One possible consequence of exposure to these xenobiotics is disruption to spermatogenesis, but results thus far provide only indirect and inconsistent evidence. In this study we exposed adult male guppies (Poeciliidae: Teleostei) to environmentally relevant levels of the common xenobiotics tributyltin (11.2-22.3 ngl-1) and bisphenol A (274-549 micrograms l-1) in experimental aquaria. After 21 days of exposure, we found significant declines (by 40-75%) in total sperm counts for male fishes exposed to tributyltin and bisphenol A compared with controls. This short-term decline in sperm count is unlikely to be the result of endocrine-mediated alteration of the germ line, and we found no change in testis size or sperm lengths between treatments. However, Sertoli cells, which facilitate the transport of maturing sperm into the testicular deferent duct (where they are stored prior to ejaculation), are directly sensitive to xenobiotic action and it is therefore possible that spermatogenesis was inhibited through in vivo interference with normal Sertoli-cell function. PMID:11413652

  20. Radioimmunoanalysis of delta-9-THC in blood by means of an /sup 125/I tracer. [Delta-9-Tetrahydrocannabinol

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Owens, S.M.; McBay, A.J.; Reisner, H.M.

    A radioimmunoassay for delta-9-THC in plasma, whole blood, or hemolyzed blood specimens has been presented. Samples and standards were diluted with methanol and centrifuged. An aliquot of the supernatant fluid was incubated with RIA buffer, /sup 125/I-labeled delta-8-THC and rabbit anti-THC serum. Solid phase goat anti-rabbit immunoglobulins were added to separate bound from free THC. After centrifugation the supernatant fluid was aspirated and the radioactivity of the precipitate was counted in a gamma counter. The concentration of THC was calculated from a standard curve using the logit-log transformation of the average counts of duplicate tubes. The assay had several advantages.more » Methanol dilution gave better results than direct analysis. The /sup 125/I-labeled THC had high specific activity and could be counted in a gamma counter. The immunological separation of antibody-bound THC from free THC was better than separation techniques using ammonium sulfate and activated charcoal. THC was determined in 0.1 ml of sample with a sensitivity of 1.5 ng/ml in plasma and 3.0 ng/ml in hemolyzed blood.« less

  1. Si-strip photon counting detectors for contrast-enhanced spectral mammography

    NASA Astrophysics Data System (ADS)

    Chen, Buxin; Reiser, Ingrid; Wessel, Jan C.; Malakhov, Nail; Wawrzyniak, Gregor; Hartsough, Neal E.; Gandhi, Thulasi; Chen, Chin-Tu; Iwanczyk, Jan S.; Barber, William C.

    2015-08-01

    We report on the development of silicon strip detectors for energy-resolved clinical mammography. Typically, X-ray integrating detectors based on scintillating cesium iodide CsI(Tl) or amorphous selenium (a-Se) are used in most commercial systems. Recently, mammography instrumentation has been introduced based on photon counting Si strip detectors. The required performance for mammography in terms of the output count rate, spatial resolution, and dynamic range must be obtained with sufficient field of view for the application, thus requiring the tiling of pixel arrays and particular scanning techniques. Room temperature Si strip detector, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel, provided that the sensors are designed for rapid signal formation across the X-ray energy ranges of the application. We present our methods and results from the optimization of Si-strip detectors for contrast enhanced spectral mammography. We describe the method being developed for quantifying iodine contrast using the energy-resolved detector with fixed thresholds. We demonstrate the feasibility of the method by scanning an iodine phantom with clinically relevant contrast levels.

  2. Robust interferon-α and IL-12 responses by dendritic cells are related to efficient CD4+ T-cell recovery in HIV patients on ART.

    PubMed

    Tan, Dino Bee Aik; Yong, Yean Kong; Lim, Andrew; Tan, Hong Yien; Kamarulzaman, Adeeba; French, Martyn; Price, Patricia

    2011-05-01

    Amongst HIV patients with successful virological responses to antiretroviral therapy (ART), poor CD4(+) T-cell recovery is associated with low nadir CD4(+) T-cell counts and persistent immune activation. These factors might be influenced by dendritic cell (DC) function. Interferon-α-producing plasmacytoid DC and IL-12-producing myeloid DC were quantified by flow cytometry after stimulation with agonists to TLR7/8 (CL075) or TLR9 (CpG-ODN). These were compared between patients who achieved CD4(+) T-cell counts above or below 200 cells/μL after 6 months on ART (High vs. Low groups). High Group patients had more DC producing interferon-α or IL-12 at Weeks 6 and 12 on ART than Low Group patients. The frequencies of cytokine-producing DC at Week 12 were directly correlated with CD4(+) T-cell counts at baseline and at Week 12. Patients with good recovery of CD4(+) T-cells had robust TLR-mediated interferon-α responses by plasmacytoid DC and IL-12 responses by myeloid DC during early ART (1-3 months). Copyright © 2011 Elsevier Inc. All rights reserved.

  3. Benefits of automated surface decontamination of a radioiodine ward.

    PubMed

    Westcott, Eliza; Broadhurst, Alicia; Crossley, Steven; Lee, Lloyd; Phan, Xuyen; Scharli, Rainer; Xu, Yan

    2012-02-01

    A floor-washing robot has been acquired to assist physicists with decontamination of radioiodine therapy ward rooms after discharge of the patient at Sir Charles Gairdner Hospital. The effectiveness of the robot in decontaminating the ward has been evaluated. A controlled experiment was performed by deliberately contaminating a polyvinyl chloride flooring offcut with 131I followed by automated decontamination with the robot. The extent of fixed and removable contamination was assessed before and after decontamination by two methods: (1) direct Geiger-Mueller counting and (2) beta-counting wipe tests. Surface contamination was also assessed in situ on the ward by Geiger-Mueller counting and wipe testing. Contamination maps confirmed that contamination was removed rather than spread around by the robot. Wipe testing revealed that the robot was successful in clearing approximately 60-80% of removable contamination. The robotic floor-washing device was considered suitable to provide effective automated decontamination of the radioiodine ward. In addition, the robot affords other benefits: the time spent by the physicists decontaminating the room is greatly reduced offering financial and occupational safety and health benefits. The robot has also found utility in other decontamination applications in the healthcare environment.

  4. Non-calcified coronary plaque volume inversely related to CD4 count in HIV infection

    PubMed Central

    Duarte, Horacio; Matta, Jatin R.; Muldoon, Nancy; Masur, Henry; Hadigan, Colleen; Gharib, Ahmed M.

    2013-01-01

    Background Non-calcified coronary artery plaque (NCAP) may be an important predictor of cardiovascular events, however, few studies have directly measured NCAP in HIV-infected individuals. Methods We completed a prospective cross-sectional evaluation of NCAP and coronary calcium scores using CT angiography in HIV-infected subjects (n=26) without known coronary artery disease (CAD), but who had one or more CAD risk factor and compared them to controls matched on age, race, sex, body mass index and Framingham risk score (n=26). Results There was no difference in coronary calcium scores (114 ± 218 vs. 124 ± 298 p=0.89) or NCAP volume (65 ± 86 mm3 vs. 63 ± 82 mm3, p=0.38) between HIV-infected subjects and controls, respectively. Among HIV-infected subjects, lower CD4 count was associated with increased NCAP volume (r=-0.52, p=0.006). CD4 count remained a significant predictor of NCAP in a multivariate analysis that adjusted for age and duration of antiretroviral therapy. Conclusion Plaque burden is similar between HIV-infected and uninfected individuals when matched on traditional CAD risk factors, however immune function may mediate the development of atherosclerosis in HIV infection. PMID:22293714

  5. Progress towards barium daughter tagging in Xe136 decay using single molecule fluorescence imaging

    NASA Astrophysics Data System (ADS)

    McDonald, Austin; NEXT Collaboration

    2017-09-01

    The existence of Majorana fermions is of great interest as it may be related to the asymmetry between matter and anti-matter particles in the universe. However, the search for them has proven to be a difficult one. Neutrino-less Double Beta decay (NLDB) offers a possible opportunity for direct observation of a Majorana Fermion. The rate for NLDB decay may be as low as 1 count /ton /year if the mass ordering is inverted. Current detector technologies have background rates between 4 to 300 count /ton /year /ROI at the 100kg scale which is much larger than the universal goal of 0.1 count /ton /year /ROI desired for ton-scale detectors. The premise of my research is to develop new detector technologies that will allow for a background-free experiment. My current work is to develop a sensor that will tag the daughter ion Ba++ from the Xe136 decay. The development of a sensor that is sensitive to single barium ion detection based on the single molecule fluorescence imaging technique is the major focus of this work. If successful, this could provide a path to a background-free experiment.

  6. Progress towards barium daughter tagging in Xe136 decay using single molecule fluorescence imaging

    NASA Astrophysics Data System (ADS)

    McDonald, Austin; Jones, Ben; Benson, Jordan; Nygren, David; NEXT Collaboration

    2017-01-01

    The existence of Majorana Fermions has been predicted, and is of great interest as it may be related to the asymmetry between matter and anti-matter particles in the universe. However, the search for them has proven to be a difficult one. Neutrino-less Double Beta decay (NLDB) offers a possible opportunity for direct observation of a Majorana Fermion. The rate for NLDB decay may be as low as 1 count / ton / year . Current detector technologies have background rates between 4 to 300 count / ton / year / ROI which is much larger than the universal goal of 0 . 1 count / ton / year / ROI desired for ton-scale detectors. The premise of my research is to develop new detector technologies that will allow for a background-free experiment. My current work is to develop a sensor that will tag the daughter ion Ba++ from the Xe136 decay. The development of a sensor that is sensitive to single barium ion detection based on the single molecule fluorescence imaging technique is the major focus of this work. If successful, this could provide a path to a background-free experiment.

  7. Reduced sperm counts in guppies (Poecilia reticulata) following exposure to low levels of tributyltin and bisphenol A.

    PubMed

    Haubruge, E; Petit, F; Gage, M J

    2000-11-22

    There is increasing evidence that normal male reproductive function can be disrupted by exposure to pollutants in the environment that can exogenously mimic, antagonize or block sex-hormone function. One possible consequence of exposure to these xenobiotics is disruption to spermatogenesis, but results thus far provide only indirect and inconsistent evidence. In this study we exposed adult male guppies (Poeciliidae: Teleostei) to environmentally relevant levels of the common xenobiotics tributyltin (11.2-22.3 ngl-1) and bisphenol A (274-549 micrograms l-1) in experimental aquaria. After 21 days of exposure, we found significant declines (by 40-75%) in total sperm counts for male fishes exposed to tributyltin and bisphenol A compared with controls. This short-term decline in sperm count is unlikely to be the result of endocrine-mediated alteration of the germ line, and we found no change in testis size or sperm lengths between treatments. However, Sertoli cells, which facilitate the transport of maturing sperm into the testicular deferent duct (where they are stored prior to ejaculation), are directly sensitive to xenobiotic action and it is therefore possible that spermatogenesis was inhibited through in vivo interference with normal Sertoli-cell function.

  8. Invited review: Low milk somatic cell count and susceptibility to mastitis.

    PubMed

    Rainard, P; Foucras, G; Boichard, D; Rupp, R

    2018-05-23

    An enduring controversy exists about low milk cell counts and susceptibility to mastitis. The concentration of milk leukocytes, or somatic cell count (SCC), is a well-established direct indicator of mammary gland inflammation that is highly correlated with the presence of a mammary infection. The SCC is also used as a trait for the selection of dairy ruminants less prone to mastitis. As selection programs favor animals with less SCC, and as milk cells contribute to the defense of the mammary gland, the idea that susceptibility to mastitis could possibly be increased in the long term has been put forward and is still widely debated. Epidemiological and experimental studies aimed at relating SCC to susceptibility to mastitis have yielded results that seem contradictory at first sight. Nevertheless, by taking into account the immunobiology of milk and mammary tissue cells and their role in the defense against infection, along with recent studies on SCC-based divergent selection of animals, the issue can be settled. Apparent SCC-linked susceptibility to mastitis is a phenotypic trait that may be linked to immunomodulation but not to selection. Copyright © 2018 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  9. Is it Worth It? Benefits in Research with Adults with Intellectual Disability

    PubMed Central

    McDonald, Katherine E.; Conroy, Nicole E.; Olick, Robert S.

    2017-01-01

    Including adults with intellectual disability in research promotes direct benefits to participants and larger societal benefits. Stakeholders may have different views of what count as benefits, and their importance. We compared views on benefits in research with adults with intellectual disability among adults with intellectual disability, family and friends, service providers, researchers, and Institutional Review Board members. We found that adults with intellectual disability value direct and indirect research benefits, and want to participate in research that offers them. Other stakeholders generally see less value in direct benefits and predict more tempered interest in research participation as compared to adults with intellectual disability. To promote respectful research participation, research policy and practice should incorporate the views of adults with intellectual disability. PMID:27893316

  10. Is It Worth It? Benefits in Research With Adults With Intellectual Disability.

    PubMed

    McDonald, Katherine E; Conroy, Nicole E; Olick, Robert S

    2016-12-01

    Including adults with intellectual disability in research promotes direct benefits to participants and larger societal benefits. Stakeholders may have different views of what count as benefits and their importance. We compared views on benefits in research with adults with intellectual disability among adults with intellectual disability, family and friends, service providers, researchers, and institutional review board members. We found that adults with intellectual disability value direct and indirect research benefits, and want to participate in research that offers them. Other stakeholders generally see less value in direct benefits and predict more tempered interest in research participation as compared to adults with intellectual disability. To promote respectful research participation, research policy and practice should incorporate the views of adults with intellectual disability.

  11. [Studies on semen quality in workers exposed to manganese and electric welding].

    PubMed

    Wu, W; Zhang, Y; Zhang, F

    1996-09-01

    Three hundred and ten workers were selected to study the effects of manganese and electric welding on male reproductive function, with 211 occupationally exposed to manganess and electric welding fume and 99 controls. Concentrations of manganese and welding fume in the air of the workplace were 0.14-5.5 mg/m3 and 6.5-82.3 mg/m3, respectively. Semen concentrations of manganese, copper, chromium, nickel, and iron in workers employed in electric welding were significantly higher than those in controls. Time from ejaculation to liquefaction of semen in exposed workers was longer than that in controls, and volume of semen, sperm count, viable sperm count and percentage were significantly lower in the exposed workers than in the controls. Stepwise regression analysis suggests a direct toxic effect of manganese on sperm production.

  12. Stomach Fermentation in East African Colobus Monkeys in Their Natural State

    PubMed Central

    Ohwaki, Kyoko; Hungate, R. E.; Lotter, Leonard; Hofmann, R. R.; Maloiy, Geoffrey

    1974-01-01

    The microbial fermentation in the stomachs of two monkeys, Colobus polykomos, collected in Kenya, was studied. The gas accumulated within the stomach contained H2 but no CH4. Volatile fatty acid concentrations were high, but accumulated acid prevented determination of the fermentation rate in untreated, incubated stomach contents. Upon addition of bicarbonate, a very rapid rate could be demonstrated. Some D- and L-lactate were in the stomach contents. Starchy seeds or fruits rather than leaves appeared to have been consumed. Microscopically, the most prominent microorganisms seen were large, very refringent cocci, possibly Sarcina ventriculi, and various smaller cocci and rods. The 28 cultured strains of bacteria included 14 Staphylococcus, 2 Streptococcus, 10 Propionibacterium, and 2 Peptostreptococcus. The culture count constituted 10 to 20% of the direct count. No protozoa or cellulolytic bacteria were found. Images PMID:4207763

  13. BACKWARD ESTIMATION OF STOCHASTIC PROCESSES WITH FAILURE EVENTS AS TIME ORIGINS1

    PubMed Central

    Gary Chan, Kwun Chuen; Wang, Mei-Cheng

    2011-01-01

    Stochastic processes often exhibit sudden systematic changes in pattern a short time before certain failure events. Examples include increase in medical costs before death and decrease in CD4 counts before AIDS diagnosis. To study such terminal behavior of stochastic processes, a natural and direct way is to align the processes using failure events as time origins. This paper studies backward stochastic processes counting time backward from failure events, and proposes one-sample nonparametric estimation of the mean of backward processes when follow-up is subject to left truncation and right censoring. We will discuss benefits of including prevalent cohort data to enlarge the identifiable region and large sample properties of the proposed estimator with related extensions. A SEER–Medicare linked data set is used to illustrate the proposed methodologies. PMID:21359167

  14. Expected total counts for the Self-Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossa, Riccardo; Universite Libre de Bruxelles; Borella, Alessandro

    2015-07-01

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in spent fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron counts in the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach in this study consisted in introducing a small neutron detector in the central guide tube of a PWR 17x17 fuelmore » assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types were used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the total neutron counts that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of total neutron counts and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the total neutron counts by increasing the detector size. The study shows that the highest total neutron counts are achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the total neutron counts associated to each detector type will play a major role in the selection of the detector types used for the SINRD measurement. (authors)« less

  15. Representation of layer-counted proxy records as probability densities on error-free time axes

    NASA Astrophysics Data System (ADS)

    Boers, Niklas; Goswami, Bedartha; Ghil, Michael

    2016-04-01

    Time series derived from paleoclimatic proxy records exhibit substantial dating uncertainties in addition to the measurement errors of the proxy values. For radiometrically dated proxy archives, Goswami et al. [1] have recently introduced a framework rooted in Bayesian statistics that successfully propagates the dating uncertainties from the time axis to the proxy axis. The resulting proxy record consists of a sequence of probability densities over the proxy values, conditioned on prescribed age values. One of the major benefits of this approach is that the proxy record is represented on an accurate, error-free time axis. Such unambiguous dating is crucial, for instance, in comparing different proxy records. This approach, however, is not directly applicable to proxy records with layer-counted chronologies, as for example ice cores, which are typically dated by counting quasi-annually deposited ice layers. Hence the nature of the chronological uncertainty in such records is fundamentally different from that in radiometrically dated ones. Here, we introduce a modification of the Goswami et al. [1] approach that is specifically designed for layer-counted proxy records, instead of radiometrically dated ones. We apply our method to isotope ratios and dust concentrations in the NGRIP core, using a published 60,000-year chronology [2]. It is shown that the further one goes into the past, the more the layer-counting errors accumulate and lead to growing uncertainties in the probability density sequence for the proxy values that results from the proposed approach. For the older parts of the record, these uncertainties affect more and more a statistically sound estimation of proxy values. This difficulty implies that great care has to be exercised when comparing and in particular aligning specific events among different layer-counted proxy records. On the other hand, when attempting to derive stochastic dynamical models from the proxy records, one is only interested in the relative changes, i.e. in the increments of the proxy values. In such cases, only the relative (non-cumulative) counting errors matter. For the example of the NGRIP records, we show that a precise estimation of these relative changes is in fact possible. References: [1] Goswami et al., Nonlin. Processes Geophys. (2014) [2] Svensson et al., Clim. Past (2008)

  16. Examining the validity of the ActivPAL monitor in measuring posture and ambulatory movement in children

    PubMed Central

    2012-01-01

    Background Decreasing sedentary activities that involve prolonged sitting may be an important strategy to reduce obesity and other physical and psychosocial health problems in children. The first step to understanding the effect of sedentary activities on children’s health is to objectively assess these activities with a valid measurement tool. Purpose To examine the validity of the ActivPAL monitor in measuring sitting/lying, standing, and walking time, transition counts and step counts in children in a laboratory setting. Methods Twenty five healthy elementary school children (age 9.9 ± 0.3 years; BMI 18.2 ± 1.9; mean ± SD) were randomly recruited across the Auckland region, New Zealand. Children were fitted with ActivPAL monitors and observed during simulated free-living activities involving sitting/lying, standing and walking, followed by treadmill and over-ground activities at various speeds (slow, normal, fast) against video observation (criterion measure). The ActivPAL sit-to-stand and stand-to-sit transition counts and steps were also compared with video data. The accuracy of step counts measured by the ActivPAL was also compared against the New Lifestyles NL-2000 and the Yamax Digi-Walker SW-200 pedometers. Results We observed a perfect correlation between the ActivPAL monitor in time spent sitting/lying, standing, and walking in simulated free-living activities with direct observation. Correlations between the ActivPAL and video observation in total numbers of sit-to-stand and stand-to-sit transitions were high (r = 0.99 ± 0.01). Unlike pedometers, the ActivPAL did not misclassify fidgeting as steps taken. Strong correlations (r = 0.88-1.00) between ActivPAL step counts and video observation in both treadmill and over-ground slow and normal walking were also observed. During treadmill and over-ground fast walking and running, the correlations were low (r = 0.21-0.46). Conclusion The ActivPAL monitor is a valid measurement tool for assessing time spent sitting/lying, standing, and walking, sit-to-stand and stand-to-sit transition counts and step counts in slow and normal walking. The device did not measure accurately steps taken during treadmill and over-ground fast walking and running in children. PMID:23031188

  17. Oral microflora and their relation to risk factors in HIV+ patients with oropharyngeal candidiasis.

    PubMed

    Sharifzadeh, A; Khosravi, A R; Shokri, H; Asadi Jamnani, F; Hajiabdolbaghi, M; Ashrafi Tamami, I

    2013-06-01

    The purpose of this study was to determine the prevalence of oral microflora and association of oral candidiasis and multiple risk factors in HIV(+) patients. The present study included 100 HIV-infected patients participated in Imam Khomeini Hospital, Tehran, Iran for Oropharyngeal candidiasis (OPC) and HIV. We assessed the presence or absence of OPC, and samples were obtained from the oral cavity and direct microscopic examination, gram staining and culture on standard microbiological media were performed in all patients. CD4(+) cell count/CD4(+) percentage were also calculated. The demographic characteristics showed that the patients had a mean age of 32.3 years old, 78% male and 22% female. Patients belonging to 'O(+)' blood group (27%) were more prone to develop OPC. A total of 460 bacterial colonies were obtained and Streptococcus mutans (15.4%) was the most frequently isolated species in the HIV(+) patients, followed by Staphylococcus epidermidis (12.8%) and Corynebacterium (8.7%). In addition, 254 yeasts (from four different genera) were isolated from the patient under study. Candida species (94.4%) were the most frequently obtained genera, followed by Saccharomyces (2.4%), Kluyveromyces and Cryptococcus (1.6% for both) species. Candida albicans (37.2%) was the most common species isolated from HIV(+) patients with OPC and its frequency was significantly higher than that of other Candida species (P<0.05). Candida glabrata, C. dubliniensis, C. tropicalis, C. parapsilosis, C. krusei, C. lusitaniae, C. guilliermondii and C. norvegensis were also identified. Forty percent of the patients had angular cheilitis as the most frequent clinical variant. The mean CD4(+) cell counts were 154.5 cells/μL, with a range of 8 to 611 cells/μL. Thirty percent patients had a CD4(+) cell count between 101 and 200 cells/μL (28.7% of total yeasts isolated). Yeast and bacteria counts did not differ statistically among HIV(+) patients' subgroups with different levels of CD4(+) cells counts. Our results showed that yeasts of the genus Candida were isolated at a comparable rate from the oral cavity of HIV(+) patients and there was no significant difference of the variables CD4(+) cell count and yeast counts. The findings of this study would be helpful in any further study, which, if done prospectively on a large cohort, can be confirmatory. Copyright © 2013. Published by Elsevier SAS.

  18. Prioritizing CD4 Count Monitoring in Response to ART in Resource-Constrained Settings: A Retrospective Application of Prediction-Based Classification

    PubMed Central

    Liu, Yan; Li, Xiaohong; Johnson, Margaret; Smith, Collette; Kamarulzaman, Adeeba bte; Montaner, Julio; Mounzer, Karam; Saag, Michael; Cahn, Pedro; Cesar, Carina; Krolewiecki, Alejandro; Sanne, Ian; Montaner, Luis J.

    2012-01-01

    Background Global programs of anti-HIV treatment depend on sustained laboratory capacity to assess treatment initiation thresholds and treatment response over time. Currently, there is no valid alternative to CD4 count testing for monitoring immunologic responses to treatment, but laboratory cost and capacity limit access to CD4 testing in resource-constrained settings. Thus, methods to prioritize patients for CD4 count testing could improve treatment monitoring by optimizing resource allocation. Methods and Findings Using a prospective cohort of HIV-infected patients (n = 1,956) monitored upon antiretroviral therapy initiation in seven clinical sites with distinct geographical and socio-economic settings, we retrospectively apply a novel prediction-based classification (PBC) modeling method. The model uses repeatedly measured biomarkers (white blood cell count and lymphocyte percent) to predict CD4+ T cell outcome through first-stage modeling and subsequent classification based on clinically relevant thresholds (CD4+ T cell count of 200 or 350 cells/µl). The algorithm correctly classified 90% (cross-validation estimate = 91.5%, standard deviation [SD] = 4.5%) of CD4 count measurements <200 cells/µl in the first year of follow-up; if laboratory testing is applied only to patients predicted to be below the 200-cells/µl threshold, we estimate a potential savings of 54.3% (SD = 4.2%) in CD4 testing capacity. A capacity savings of 34% (SD = 3.9%) is predicted using a CD4 threshold of 350 cells/µl. Similar results were obtained over the 3 y of follow-up available (n = 619). Limitations include a need for future economic healthcare outcome analysis, a need for assessment of extensibility beyond the 3-y observation time, and the need to assign a false positive threshold. Conclusions Our results support the use of PBC modeling as a triage point at the laboratory, lessening the need for laboratory-based CD4+ T cell count testing; implementation of this tool could help optimize the use of laboratory resources, directing CD4 testing towards higher-risk patients. However, further prospective studies and economic analyses are needed to demonstrate that the PBC model can be effectively applied in clinical settings. Please see later in the article for the Editors' Summary PMID:22529752

  19. Marginalized multilevel hurdle and zero-inflated models for overdispersed and correlated count data with excess zeros.

    PubMed

    Kassahun, Wondwosen; Neyens, Thomas; Molenberghs, Geert; Faes, Christel; Verbeke, Geert

    2014-11-10

    Count data are collected repeatedly over time in many applications, such as biology, epidemiology, and public health. Such data are often characterized by the following three features. First, correlation due to the repeated measures is usually accounted for using subject-specific random effects, which are assumed to be normally distributed. Second, the sample variance may exceed the mean, and hence, the theoretical mean-variance relationship is violated, leading to overdispersion. This is usually allowed for based on a hierarchical approach, combining a Poisson model with gamma distributed random effects. Third, an excess of zeros beyond what standard count distributions can predict is often handled by either the hurdle or the zero-inflated model. A zero-inflated model assumes two processes as sources of zeros and combines a count distribution with a discrete point mass as a mixture, while the hurdle model separately handles zero observations and positive counts, where then a truncated-at-zero count distribution is used for the non-zero state. In practice, however, all these three features can appear simultaneously. Hence, a modeling framework that incorporates all three is necessary, and this presents challenges for the data analysis. Such models, when conditionally specified, will naturally have a subject-specific interpretation. However, adopting their purposefully modified marginalized versions leads to a direct marginal or population-averaged interpretation for parameter estimates of covariate effects, which is the primary interest in many applications. In this paper, we present a marginalized hurdle model and a marginalized zero-inflated model for correlated and overdispersed count data with excess zero observations and then illustrate these further with two case studies. The first dataset focuses on the Anopheles mosquito density around a hydroelectric dam, while adolescents' involvement in work, to earn money and support their families or themselves, is studied in the second example. Sub-models, which result from omitting zero-inflation and/or overdispersion features, are also considered for comparison's purpose. Analysis of the two datasets showed that accounting for the correlation, overdispersion, and excess zeros simultaneously resulted in a better fit to the data and, more importantly, that omission of any of them leads to incorrect marginal inference and erroneous conclusions about covariate effects. Copyright © 2014 John Wiley & Sons, Ltd.

  20. Impact of oral Lactobacillus acidophilus gavage on rooster seminal and cloacal Lactobacilli concentrations.

    PubMed

    Kiess, A S; Hirai, J H; Triplett, M D; Parker, H M; McDaniel, C D

    2016-08-01

    The use of antibiotics in poultry is being heavily scrutinized, therefore alternatives such as probiotics are being investigated. Lactobacilli spp. are a commonly used bacteria in formulating probiotics, and the addition of Lactobacilli to broiler diets has demonstrated increased growth rates, stimulated immune systems, and reduced pathogen loads in the gastro-intestinal tract ( GI: ) tract. However, previous research has shown that when rooster semen is directly exposed to Lactobacillus acidophilus (L. acidophilus) sperm quality is reduced. Therefore, the objective of the current study was to determine if oral administration of L. acidophilus increases the concentration of Lactobacilli in semen as well as the cloaca. A total of 30 roosters were used: 15 roosters were gavaged with 1X PBS (Control) and 15 roosters were gavaged with 10(7) cfu/mL of L. acidophilus (Treated). All roosters were gavaged for 14 consecutive days. Semen was collected on a 3 d interval, and cloacal swabs were collected on a 2 d interval, beginning on the first day prior to oral administration. Semen and cloacal swabs were serial diluted, and 100 μL of each dilution was then plated on Man, Rogosa, Sharpe ( MRS: ) agar plates. All plates were incubated for 48 h at 37°C under anaerobic conditions and counted. All Lactobacilli counts were first log transformed, then log transformed (day 0) pre-counts were subtracted from the log transformed day counts providing log differences for the analysis. Seminal Lactobacilli counts were not altered by treatments. However, the main effect of treatment (P = 0.026) for cloacal counts indicated that roosters gavaged with Lactobacilli yielded higher counts than the controls. Additionally, cloaca samples also demonstrated a treatment by day interaction trend (P = 0.082), where Lactobacilli was higher in the L. acidophilus gavaged roosters than the controls only on days 3, 5, 13, and 15. In conclusion, the addition of L. acidophilus to the male breeder diet over extended periods may increase concentrations of Lactobacilli in the cloaca even higher than the concentrations observed in this study. If Lactobacilli reaches high enough concentrations in the cloaca, then sperm quality may be impacted which could lead to poor fertility within the breeder flock. © 2016 Poultry Science Association Inc.

  1. Weirs: Counting and sampling adult salmonids in streams and rivers

    USGS Publications Warehouse

    Zimmerman, Christian E.; Zabkar, Laura M.; Johnson, David H.; Shrier, Brianna M.; O'Neal, Jennifer S.; Knutzen, John A.; Augerot, Xanthippe; O'Neal, Thomas A.; Pearsons, Todd N.

    2007-01-01

    Weirs—which function as porous barriers built across stream—have long been used to capture migrating fish in flowing waters. For example, the Netsilik peoples of northern Canada used V-shaped weirs constructed of river rocks gathered onsite to capture migrating Arctic char Salvelinus alpinus (Balikci 1970). Similarly, fences constructed of stakes and a latticework of willow branches or staves were used by Native Americans to capture migrating salmon in streams along the West Coast of North America (Stewart 1994). In modern times, weirs have also been used in terminal fisheries and to capture brood fish for use in fish culture. Weirs have been used to gather data on age structure, condition, sex ratio, spawning escapement, abundance, and migratory patterns of fish in streams. One of the critical elements of fisheries management and stock assessment of salmonids is a count of adult fish returning to spawn. Weirs are frequently used to capture or count fish to determine status and trends of populations or direct inseason management of fisheries; generally, weirs are the standard against which other techniques are measured. To evaluate fishery management actions, the number of fish escaping to spawn is often compared to river-specific target spawning requirements (O’Connell and Dempson 1995). A critical factor in these analyses is the determination of total run size (O’Connell 2003). O’Connell compared methods of run-size estimation against absolute counts from a rigid weir and concluded that, given the uncertainty of estimators, the absolute counts obtained at the weir wer significantly better than modeled estimates, which deviated as much as 50–60% from actual counts. The use of weirs is generally restricted to streams and small rivers because of construction expense, formation of navigation barriers, and the tendency of weirs to clog with debris, which can cause flooding and collapse of the structure (Hubert 1996). When feasible, however, weirs are generally regarded as the most accurate technique available to quantify escapement as the result is supposedly an absolute count (Cousens et al. 1982). Weirs also provide the opportunity to capture fish for observation and sampling of biological characteristics and tissues; they may also serve as recapture sites for basin-wide, mark–recapture population estimates. Temporary weirs are useful in monitoring wild populations of salmonids as well as for capturing broodstock for artificial propagation.

  2. Direct phenotypic and genotypic detection of a recombinant pseudomonad population released into lake water.

    PubMed Central

    Morgan, J A; Winstanley, C; Pickup, R W; Jones, J G; Saunders, J R

    1989-01-01

    As a system for studying the fate of genetically engineered microorganisms in the environment, we have previously constructed recombinant plasmids encoding a xylE marker gene (C. Winstanley, J. A. W. Morgan, R. W. Pickup, J. G. Jones, and J. R. Saunders, Appl. Environ. Microbiol. 55:771-777, 1989). A series of direct membrane filter methods have been developed which facilitate the detection of bacterial cells harboring the xylE gene, its product, catechol 2,3-dioxygenase, and catechol 2,3-dioxygenase enzyme activity directly from water samples. These methods enable detection of recombinant populations at concentrations as low as 10(3) to 10(4) cells ml of lake water-1. Direct detection facilitates ecological studies of a range of bacterial strains containing the marker system in aquatic environments. The fate of a recombinant pseudomonad population in lake water was assessed by a combination of colony-forming ability, direct counts, and direct detection of the xylE gene and phenotypic expression of its product. Images PMID:2604395

  3. 2011 investigation of internal contamination with radioactive strontium following rubidium Rb 82 cardiac PET scan.

    PubMed

    Pillai, Satish K; Chang, Arthur; Murphy, Matthew W; Buzzell, Jennifer; Ansari, Armin; Whitcomb, Robert C; Miller, Charles; Jones, Robert; Saunders, David P; Cavicchia, Philip; Watkins, Sharon M; Blackmore, Carina; Williamson, John A; Stephens, Michael; Morrison, Melissa; McNees, James; Murphree, Rendi; Buchanan, Martha; Hogan, Anthony; Lando, James; Nambiar, Atmaram; Torso, Lauren; Melnic, Joseph M; Yang, Lucie; Lewis, Lauren

    2014-01-01

    During routine screening in 2011, US Customs and Border Protection (CBP) identified 2 persons with elevated radioactivity. CBP, in collaboration with Los Alamos National Laboratory, informed the Food and Drug Administration (FDA) that these people could have increased radiation exposure as a result of undergoing cardiac Positron Emission Tomography (PET) scans several months earlier with rubidium Rb 82 chloride injection from CardioGen-82. We conducted a multistate investigation to assess the potential extent and magnitude of radioactive strontium overexposure among patients who had undergone Rb 82 PET scans. We selected a convenience sample of clinical sites in 4 states and reviewed records to identify eligible study participants, defined as people who had had an Rb 82 PET scan between February and July 2011. All participants received direct radiation screening using a radioisotope identifier able to detect the gamma energy specific for strontium-85 (514 keV) and urine bioassay for excreted radioactive strontium. We referred a subset of participants with direct radiation screening counts above background readings for whole body counting (WBC) using a rank ordering of direct radiation screening. The rank order list, from highest to lowest, was used to contact and offer voluntary enrollment for WBC. Of 308 participants, 292 (95%) had direct radiation screening results indistinguishable from background radiation measurements; 261 of 265 (98%) participants with sufficient urine for analysis had radioactive strontium results below minimum detectable activity. None of the 23 participants who underwent WBC demonstrated elevated strontium activity above levels associated with routine use of the rubidium Rb 82 generator. Among investigation participants, we did not identify evidence of strontium internal contamination above permissible levels. This investigation might serve as a model for future investigations of radioactive internal contamination incidents.

  4. Lab-on-a-chip for the isolation and characterization of circulating tumor cells.

    PubMed

    Stakenborg, Tim; Liu, Chengxu; Henry, Olivier; O'Sullivan, Ciara K; Fermer, Christian; Roeser, Tina; Ritzi-Lehnert, Marion; Hauch, Sigfried; Borgen, Elin; Laddach, Nadja; Lagae, Liesbet

    2010-01-01

    A smart miniaturized system is being proposed for the isolation and characterization of circulating tumor cells (CTCs) directly from blood. Different microfluidic modules have been designed for cell enrichment and -counting, multiplex mRNA amplification as well as DNA detection. With the different modules at hand, future effort will focus on the integration of the modules in a fully automated, single platform.

  5. Scanning Defect Mapping | Photovoltaic Research | NREL

    Science.gov Websites

    SDMS moves the treated wafer across a stationary laser beam and maps the defects for each location on the wafer. The amount of light reflected from an area is proportional to the dislocation density for that area and provides a direct statistical count of the number of dislocations. PV Research Other

  6. Quantitative and qualitative analysis of palatal rugae patterns in Gujarati population: A retrospective, cross-sectional study.

    PubMed

    Pillai, Jayasankar; Banker, Alka; Bhattacharya, Amit; Gandhi, Radha; Patel, Nupur; Parikh, Sarthak

    2016-01-01

    Palatal rugae are irregular and nonidentical mucosal elevations seen on the anterior third of palate. They are arranged in transverse direction on either side of the median palatine raphe (MPR) and are protected from high temperature and trauma because of their rational position in the oral cavity. Their number and patterns are not uniform in all the individuals, and they appear to vary in different population subsets. The study of palatal rugae is termed as "Rugoscopy" or "Palatoscopy", and it finds its application in various fields such as anthropology, orthodontics, forensic sciences; including forensic odonto-stomatology. The aim of this study was to evaluate the quantitative and qualitative parameters of palatal rugae using pre-orthodontic study models of Gujarati samples. (1) To identify the predominant palatal arch forms in the study samples. (2) To evaluate and correlate the rugae count in both male and female samples with the different palatal arch forms. (3) To assess the symmetry and/or asymmetry in rugae count between the right and left side. (4) To analyze and correlate the qualitative characters such as size, shape, direction, and unification in male and female study samples. One hundred pre-orthodontic maxillary dental stone casts of patients with an age range of 17-25 years were selected. The outlines of the rugae were traced using microtip graphite pencil and examined using magnifying glass for different patterns. The quantity and quality of rugae patterns were recorded according to Thomas et al . classification and the data were statistically analyzed by the statistician using SPSS program. Overall, 962 rugae were observed in the study sample. The mean rugae count was 9.86 in males and 9.38 in females. The left side rugae count was more than the right side in both the sexes and it was not statistically significant. Fifty-six percent of the samples showed asymmetry in rugae count between the right and left. Class B palatal arch form was the most common type in the study samples. The number of primary rugae count was more in both the sexes. The distribution of straight (40.2%) and curved (40.4%) types of rugae were almost equal in males but in females, the straight rugae pattern (42.2%) was more than the curved (36.9%), followed by wavy and circular. Of 962 rugae, 36.4% were of horizontal type followed by forward (33.4%) and backward (29.2%). About 1 % of rugae showed perpendicular pattern and only 9.25% showed unification pattern and the divergent type of unification was more common than the convergent type. There is no gender discrimination in relation to any of the metric or non-metric parameters of the palatal rugae in this study samples. No two samples showed similarity in the distribution of palatal rugae patterns. The straight and horizontal rugae distributions were predominant in our Gujarati Study samples.

  7. Evaluating the ability of regional models to predict local avian abundance

    USGS Publications Warehouse

    LeBrun, Jaymi J.; Thogmartin, Wayne E.; Miller, James R.

    2012-01-01

    Spatial modeling over broad scales can potentially direct conservation efforts to areas with high species-specific abundances. We examined the performance of regional models for predicting bird abundance at spatial scales typically addressed in conservation planning. Specifically, we used point count data on wood thrush (Hylocichla mustelina) and blue-winged warbler (Vermivora cyanoptera) from 2 time periods (1995-1998 and 2006-2007) to evaluate the ability of regional models derived via Bayesian hierarchical techniques to predict bird abundance. We developed models for each species within Bird Conservation Region (BCR) 23 in the upper midwestern United States at 800-ha, 8,000-ha, and approximately 80,000-ha scales. We obtained count data from the Breeding Bird Survey and land cover data from the National Land Cover Dataset (1992). We evaluated predictions from the best models, as defined by an information-theoretic criterion, using point count data collected within an ecological subregion of BCR 23 at 131 count stations in the 1990s and again in 2006-2007. Competing (Deviance Information Criteria rs = 0.57; P = 0.14), the survey period that most closely aligned with the time period of data used for regional model construction. Wood thrush models exhibited positive correlations with point count data for all survey areas and years combined (rs = 0.58, P ≤ 0.001). In comparison, blue-winged warbler models performed worse as time increased between the point count surveys and vintage of the model building data (rs = 0.03, P = 0.92 for Iowa and rs = 0.13, P = 0.51 for all areas, 2006-2007), likely related to the ephemeral nature of their preferred early successional habitat. Species abundance and sensitivity to changing habitat conditions seems to be an important factor in determining the predictive ability of regional models. Hierarchical models can be a useful tool for concentrating efforts at the scale of management units and should be one of many tools used by land managers, but we caution that the utility of such models may decrease over time for species preferring relatively ephemeral habitats if model inputs are not updated accordingly.

  8. Expected count rate for the Self- Interrogation Neutron Resonance Densitometry measurements of spent nuclear fuel

    DOE Office of Scientific and Technical Information (OSTI.GOV)

    Rossa, Riccardo; Universite libre de Bruxelles, Ecole polytechnique de Bruxelles - Service de Metrologie Nucleaire, CP 165/84, Avenue F.D. Roosevelt, 50 - B1050 Brussels; Borella, Alessandro

    The Self-Interrogation Neutron Resonance Densitometry (SINRD) is a passive neutron technique that aims at a direct quantification of {sup 239}Pu in the fuel assemblies by measuring the attenuation of the neutron flux in the energy region close to the 0.3 eV resonance of {sup 239}Pu. The {sup 239}Pu mass is estimated by calculating the SINRD signature, that is the ratio between the neutron flux integrated over the fast energy region and around the 0.3 eV resonance region. The SINRD measurement approach considered in this study consists in introducing a small neutron detector in the central guide tube of a PWRmore » 17x17 fuel assembly. In order to measure the neutron flux in the energy regions defined in the SINRD signature, different detector types are used. The response of a bare {sup 238}U fission chamber is considered for the determination of the fast neutron flux, while other thermal-epithermal detectors wrapped in neutron absorbers are envisaged to measure the neutron flux around the resonance region. This paper provides an estimation of the count rate that can be achieved with the detector types proposed for the SINRD measurement. In the first section a set of detectors are evaluated in terms of count rate and sensitivity to the {sup 239}Pu content, in order to identify the optimal measurement configuration for each detector type. Then a study is performed to increase the count rate by increasing the detector size. The study shows that the highest count rate is achieved by using either {sup 3}He or {sup 10}B proportional counters because of the high neutron efficiency of these detectors. However, the calculations indicate that the biggest contribution to the measurement uncertainty is due to the measurement of the fast neutron flux. Finally, similar sensitivity to the {sup 239}Pu content is obtained by using the different detector types for the measurement of the neutron flux close to the resonance region. Therefore, the count rate associated to each detector type will play a major role in the selection of the detector types used for the SINRD measurement. (authors)« less

  9. Impact of Bisphosphonate on Orthodontic tooth movement and osteoclastic count: An Animal Study.

    PubMed

    Venkataramana, V; Chidambaram, S; Reddy, B Vishnuvardhan; Goud, E V Soma Shekara; Arafath, Mohammed; Krishnan6, Santhana

    2014-04-01

    Background : The aim of the current study is to examine the effect of systemically administered BP-Pamidronate, on Orthodontic Tooth Movement (OTM) along with osteoclastic quantification in New Zealand white rabbits. Materials & Methods : Twenty rabbits used in the study, were equally divided into 2 groups ; Group-1 as Control & Group-2 as Experimental. A sentalloy NITI closed coil spring (GAC International, USA) of 100 gram force, ligated between the lower first molar and the anterior most incisors of the rabbit has served as orthodontic force element. The BP- Pamidronate was administered at the dosage of 1.5 mg/kg body intra-peritonially, on the 1st, 7th and 14th day of the experiment. On the 21st day both group of animals were sacrificed, mandibles were dissected. The formed diastema between the 1st and 2nd molar was measured on the dissected mandibles using standard metric scale, which is considered as the OTM in the mesial direction. Next, the alveolar bone regions along with intact mesial surfaces were processed for histological investigation (osteoclastic count). Results : The student 't' test has been done to compare the mean values of molar tooth movement and osteoclastic count. Parameter :1 molar tooth movement has shown a significant difference between the control (3.750 ± 0.548 mm) and the experimental group (3.050 ± 0.556 mm) with calculated 'p' value (p-value <0.05) is significant at 0.0110 level. Parameter : 2 osteoclastic count has shown a significant difference between the control (13.335000 ± 0.735856 per square mm.) and the experimental group (11.426900 ± 1.49369 per square mm) calculated 'p' value (p-value <0.05) is significant at 0.003 level. Conclusion : The molar tooth movement and the osteoclastic count were significantly reduced in BP - Pamidronate administered animals than non-drug recipients. How to cite the article: Venkataramana V, Chidambaram S, Reddy BV, Goud EV, Arafath M, Krishnan S. Impact of Bisphosphonate on Orthodontic tooth movement and olsteoclastic count: An Animal Study. J Int Oral Health 2014;6(2):1-8.

  10. Impact of Bisphosphonate on Orthodontic tooth movement and osteoclastic count: An Animal Study

    PubMed Central

    Venkataramana, V; Chidambaram, S; Reddy, B Vishnuvardhan; Goud, E V Soma Shekara; Arafath, Mohammed; Krishnan, Santhana

    2014-01-01

    Background : The aim of the current study is to examine the effect of systemically administered BP-Pamidronate, on Orthodontic Tooth Movement (OTM) along with osteoclastic quantification in New Zealand white rabbits. Materials & Methods : Twenty rabbits used in the study, were equally divided into 2 groups ; Group-1 as Control & Group-2 as Experimental. A sentalloy NITI closed coil spring (GAC International, USA) of 100 gram force, ligated between the lower first molar and the anterior most incisors of the rabbit has served as orthodontic force element. The BP- Pamidronate was administered at the dosage of 1.5 mg/kg body intra-peritonially, on the 1st, 7th and 14th day of the experiment. On the 21st day both group of animals were sacrificed, mandibles were dissected. The formed diastema between the 1st and 2nd molar was measured on the dissected mandibles using standard metric scale, which is considered as the OTM in the mesial direction. Next, the alveolar bone regions along with intact mesial surfaces were processed for histological investigation (osteoclastic count). Results : The student ‘t’ test has been done to compare the mean values of molar tooth movement and osteoclastic count. Parameter :1 molar tooth movement has shown a significant difference between the control (3.750 ± 0.548 mm) and the experimental group (3.050 ± 0.556 mm) with calculated ‘p’ value (p-value <0.05) is significant at 0.0110 level. Parameter : 2 osteoclastic count has shown a significant difference between the control (13.335000 ± 0.735856 per square mm.) and the experimental group (11.426900 ± 1.49369 per square mm) calculated ‘p’ value (p-value <0.05) is significant at 0.003 level. Conclusion : The molar tooth movement and the osteoclastic count were significantly reduced in BP – Pamidronate administered animals than non-drug recipients. How to cite the article: Venkataramana V, Chidambaram S, Reddy BV, Goud EV, Arafath M, Krishnan S. Impact of Bisphosphonate on Orthodontic tooth movement and olsteoclastic count: An Animal Study. J Int Oral Health 2014;6(2):1-8. PMID:24876695

  11. Identification of dairy farm management practices associated with the presence of psychrotolerant sporeformers in bulk tank milk.

    PubMed

    Masiello, S N; Martin, N H; Watters, R D; Galton, D M; Schukken, Y H; Wiedmann, M; Boor, K J

    2014-07-01

    Some strains of sporeforming bacteria (e.g., Bacillus spp. and Paenibacillus spp.) can survive pasteurization and subsequently grow at refrigeration temperatures, causing pasteurized fluid milk spoilage. To identify farm management practices associated with different levels of sporeformers in raw milk, a bulk tank sample was obtained from and a management and herd health questionnaire was administered to 99 New York State dairy farms. Milk samples were spore pasteurized [80°C (176°F) for 12 min] and subsequently analyzed for most-probable number and for sporeformer counts on the initial day of spore pasteurization (SP), and after refrigerated storage (6°C) at 7, 14, and 21 d after SP. Management practices were analyzed for association with sporeformer counts and bulk tank somatic cell counts. Sixty-two farms had high sporeformer growth (≥3 log cfu/mL at any day after SP), with an average sporeformer count of 5.20 ± 1.41 mean log10 cfu/mL at 21 d after SP. Thirty-seven farms had low sporeformer numbers (<3 log cfu/mL for all days after SP), with an average sporeformer count of 0.75 ± 0.94 mean log10 cfu/mL at 21 d after SP. Farms with >25% of cows with dirty udders in the milking parlor were 3.15 times more likely to be in the high category than farms with ≤10% of milking cows with dirty udders. Farms with <200 cows were 3.61 times more likely to be in the high category than farms with ≥200 cows. Management practices significantly associated with increased bulk tank somatic cell count were a lack of use of the California mastitis test at freshening and >25% of cows with dirty udders observed in the milking parlor. Changes in management practices associated with cow cleanliness may directly ensure longer shelf life and higher quality of pasteurized fluid milk. Copyright © 2014 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.

  12. Interferometric angle monitor

    NASA Technical Reports Server (NTRS)

    Minott, P. O. (Inventor)

    1983-01-01

    Two mutually coherent light beams formed from a single monochromatic light source were directed to a reflecting surface of a rotatable object. They were reflected into an imaging optical lens having a focal plane optically at infinity. A series of interference fringes were formed in the focal plane which were translated linearly in response to angular rotation of the object. Photodetectors were located adjacent the focal plane to detect the fringe translation and output a signal in response to the translation. The signal was fed to a signal processor which was adapted to count the number of fringes detected and develop a measure of the angular rotation and direction of the object.

  13. Direct nn-Scattering Measurement With the Pulsed Reactor YAGUAR.

    PubMed

    Mitchell, G E; Furman, W I; Lychagin, E V; Muzichka, A Yu; Nekhaev, G V; Strelkov, A V; Sharapov, E I; Shvetsov, V N; Chernuhin, Yu I; Levakov, B G; Litvin, V I; Lyzhin, A E; Magda, E P; Crawford, B E; Stephenson, S L; Howell, C R; Tornow, W

    2005-01-01

    Although crucial for resolving the issue of charge symmetry in the nuclear force, direct measurement of nn-scattering by colliding free neutrons has never been performed. At present the Russian pulsed reactor YAGUAR is the best neutron source for performing such a measurement. It has a through channel where the neutron moderator is installed. The neutrons are counted by a neutron detector located 12 m from the reactor. In preliminary experiments an instantaneous value of 1.1 × 10(18)/cm(2)s was obtained for the thermal neutron flux density. The experiment will be performed by the DIANNA Collaboration as International Science & Technology Center (ISTC) project No. 2286.

  14. Direct nn-Scattering Measurement With the Pulsed Reactor YAGUAR

    PubMed Central

    Mitchell, G. E.; Furman, W. I.; Lychagin, E. V.; Muzichka, A. Yu.; Nekhaev, G. V.; Strelkov, A. V.; Sharapov, E. I.; Shvetsov, V. N.; Chernuhin, Yu. I.; Levakov, B. G.; Litvin, V. I.; Lyzhin, A. E.; Magda, E. P.; Crawford, B. E.; Stephenson, S. L.; Howell, C. R.; Tornow, W

    2005-01-01

    Although crucial for resolving the issue of charge symmetry in the nuclear force, direct measurement of nn-scattering by colliding free neutrons has never been performed. At present the Russian pulsed reactor YAGUAR is the best neutron source for performing such a measurement. It has a through channel where the neutron moderator is installed. The neutrons are counted by a neutron detector located 12 m from the reactor. In preliminary experiments an instantaneous value of 1.1 × 1018/cm2s was obtained for the thermal neutron flux density. The experiment will be performed by the DIANNA Collaboration as International Science & Technology Center (ISTC) project No. 2286. PMID:27308126

  15. Incomplete Detection of Nonclassical Phase-Space Distributions

    NASA Astrophysics Data System (ADS)

    Bohmann, M.; Tiedau, J.; Bartley, T.; Sperling, J.; Silberhorn, C.; Vogel, W.

    2018-02-01

    We implement the direct sampling of negative phase-space functions via unbalanced homodyne measurement using click-counting detectors. The negativities significantly certify nonclassical light in the high-loss regime using a small number of detectors which cannot resolve individual photons. We apply our method to heralded single-photon states and experimentally demonstrate the most significant certification of nonclassicality for only two detection bins. By contrast, the frequently applied Wigner function fails to directly indicate such quantum characteristics for the quantum efficiencies present in our setup without applying additional reconstruction algorithms. Therefore, we realize a robust and reliable approach to characterize nonclassical light in phase space under realistic conditions.

  16. Hardware support for collecting performance counters directly to memory

    DOEpatents

    Gara, Alan; Salapura, Valentina; Wisniewski, Robert W.

    2012-09-25

    Hardware support for collecting performance counters directly to memory, in one aspect, may include a plurality of performance counters operable to collect one or more counts of one or more selected activities. A first storage element may be operable to store an address of a memory location. A second storage element may be operable to store a value indicating whether the hardware should begin copying. A state machine may be operable to detect the value in the second storage element and trigger hardware copying of data in selected one or more of the plurality of performance counters to the memory location whose address is stored in the first storage element.

  17. Method and apparatus for measuring frequency and phase difference

    NASA Technical Reports Server (NTRS)

    Shores, Paul (Inventor); Lichtenberg, Christopher (Inventor); Kobayashi, Herbert S. (Inventor); Cunningham, Allen R. (Inventor)

    1986-01-01

    The present invention is a system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams are directed toward a target and corresponding beams returning therefrom are detected. A digital difference circuit forms a pulse train from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display are correlative to target position relative to beams.

  18. Design optimization for a wearable, gamma-ray and neutron sensitive, detector array with directionality estimation

    NASA Astrophysics Data System (ADS)

    Ayaz-Maierhafer, Birsen; Britt, Carl G.; August, Andrew J.; Qi, Hairong; Seifert, Carolyn E.; Hayward, Jason P.

    2017-10-01

    In this study, we report on a constrained optimization and tradeoff study of a hybrid, wearable detector array having directional sensing based upon gamma-ray occlusion. One resulting design uses CLYC detectors while the second feasibility design involves the coupling of gamma-ray-sensitive CsI scintillators and a rubber LiCaAlF6 (LiCAF) neutron detector. The detector systems' responses were investigated through simulation as a function of angle in a two-dimensional plane. The expected total counts, peak-to-total ratio, directionality performance, and detection of 40 K for accurate gain stabilization were considered in the optimization. Source directionality estimation was investigated using Bayesian algorithms. Gamma-ray energies of 122 keV, 662 keV, and 1332 keV were considered. The equivalent neutron capture response compared with 3 He was also investigated for both designs.

  19. A direct-to-drive neural data acquisition system.

    PubMed

    Kinney, Justin P; Bernstein, Jacob G; Meyer, Andrew J; Barber, Jessica B; Bolivar, Marti; Newbold, Bryan; Scholvin, Jorg; Moore-Kochlacs, Caroline; Wentz, Christian T; Kopell, Nancy J; Boyden, Edward S

    2015-01-01

    Driven by the increasing channel count of neural probes, there is much effort being directed to creating increasingly scalable electrophysiology data acquisition (DAQ) systems. However, all such systems still rely on personal computers for data storage, and thus are limited by the bandwidth and cost of the computers, especially as the scale of recording increases. Here we present a novel architecture in which a digital processor receives data from an analog-to-digital converter, and writes that data directly to hard drives, without the need for a personal computer to serve as an intermediary in the DAQ process. This minimalist architecture may support exceptionally high data throughput, without incurring costs to support unnecessary hardware and overhead associated with personal computers, thus facilitating scaling of electrophysiological recording in the future.

  20. A direct-to-drive neural data acquisition system

    PubMed Central

    Kinney, Justin P.; Bernstein, Jacob G.; Meyer, Andrew J.; Barber, Jessica B.; Bolivar, Marti; Newbold, Bryan; Scholvin, Jorg; Moore-Kochlacs, Caroline; Wentz, Christian T.; Kopell, Nancy J.; Boyden, Edward S.

    2015-01-01

    Driven by the increasing channel count of neural probes, there is much effort being directed to creating increasingly scalable electrophysiology data acquisition (DAQ) systems. However, all such systems still rely on personal computers for data storage, and thus are limited by the bandwidth and cost of the computers, especially as the scale of recording increases. Here we present a novel architecture in which a digital processor receives data from an analog-to-digital converter, and writes that data directly to hard drives, without the need for a personal computer to serve as an intermediary in the DAQ process. This minimalist architecture may support exceptionally high data throughput, without incurring costs to support unnecessary hardware and overhead associated with personal computers, thus facilitating scaling of electrophysiological recording in the future. PMID:26388740

Top