The detection of fecal pollution is performed via culturing methods in spite of the fact that culturable counts can severely underestimate the densities of fecal microorganisms. One approach that has been used to enumerate bacteria is the direct viable count method (DVC). The ob...
Rapid enumeration of viable bacteria by image analysis
NASA Technical Reports Server (NTRS)
Singh, A.; Pyle, B. H.; McFeters, G. A.
1989-01-01
A direct viable counting method for enumerating viable bacteria was modified and made compatible with image analysis. A comparison was made between viable cell counts determined by the spread plate method and direct viable counts obtained using epifluorescence microscopy either manually or by automatic image analysis. Cultures of Escherichia coli, Salmonella typhimurium, Vibrio cholerae, Yersinia enterocolitica and Pseudomonas aeruginosa were incubated at 35 degrees C in a dilute nutrient medium containing nalidixic acid. Filtered samples were stained for epifluorescence microscopy and analysed manually as well as by image analysis. Cells enlarged after incubation were considered viable. The viable cell counts determined using image analysis were higher than those obtained by either the direct manual count of viable cells or spread plate methods. The volume of sample filtered or the number of cells in the original sample did not influence the efficiency of the method. However, the optimal concentration of nalidixic acid (2.5-20 micrograms ml-1) and length of incubation (4-8 h) varied with the culture tested. The results of this study showed that under optimal conditions, the modification of the direct viable count method in combination with image analysis microscopy provided an efficient and quantitative technique for counting viable bacteria in a short time.
Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination.
Kitamura, Yutaka; Watanabe, Taisuke; Nakamura, Masayuki; Isobe, Kazushige; Kawabata, Hideo; Uematsu, Kohya; Okuda, Kazuhiro; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki
2018-01-01
Platelet-rich fibrin (PRF) clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP) fractions were clotted with CaCl 2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix.
Platelet Counts in Insoluble Platelet-Rich Fibrin Clots: A Direct Method for Accurate Determination
Kitamura, Yutaka; Watanabe, Taisuke; Nakamura, Masayuki; Isobe, Kazushige; Kawabata, Hideo; Uematsu, Kohya; Okuda, Kazuhiro; Nakata, Koh; Tanaka, Takaaki; Kawase, Tomoyuki
2018-01-01
Platelet-rich fibrin (PRF) clots have been used in regenerative dentistry most often, with the assumption that growth factor levels are concentrated in proportion to the platelet concentration. Platelet counts in PRF are generally determined indirectly by platelet counting in other liquid fractions. This study shows a method for direct estimation of platelet counts in PRF. To validate this method by determination of the recovery rate, whole-blood samples were obtained with an anticoagulant from healthy donors, and platelet-rich plasma (PRP) fractions were clotted with CaCl2 by centrifugation and digested with tissue-plasminogen activator. Platelet counts were estimated before clotting and after digestion using an automatic hemocytometer. The method was then tested on PRF clots. The quality of platelets was examined by scanning electron microscopy and flow cytometry. In PRP-derived fibrin matrices, the recovery rate of platelets and white blood cells was 91.6 and 74.6%, respectively, after 24 h of digestion. In PRF clots associated with small and large red thrombi, platelet counts were 92.6 and 67.2% of the respective total platelet counts. These findings suggest that our direct method is sufficient for estimating the number of platelets trapped in an insoluble fibrin matrix and for determining that platelets are distributed in PRF clots and red thrombi roughly in proportion to their individual volumes. Therefore, we propose this direct digestion method for more accurate estimation of platelet counts in most types of platelet-enriched fibrin matrix. PMID:29450197
Comment on: 'A Poisson resampling method for simulating reduced counts in nuclear medicine images'.
de Nijs, Robin
2015-07-21
In order to be able to calculate half-count images from already acquired data, White and Lawson published their method based on Poisson resampling. They verified their method experimentally by measurements with a Co-57 flood source. In this comment their results are reproduced and confirmed by a direct numerical simulation in Matlab. Not only Poisson resampling, but also two direct redrawing methods were investigated. Redrawing methods were based on a Poisson and a Gaussian distribution. Mean, standard deviation, skewness and excess kurtosis half-count/full-count ratios were determined for all methods, and compared to the theoretical values for a Poisson distribution. Statistical parameters showed the same behavior as in the original note and showed the superiority of the Poisson resampling method. Rounding off before saving of the half count image had a severe impact on counting statistics for counts below 100. Only Poisson resampling was not affected by this, while Gaussian redrawing was less affected by it than Poisson redrawing. Poisson resampling is the method of choice, when simulating half-count (or less) images from full-count images. It simulates correctly the statistical properties, also in the case of rounding off of the images.
SURVIVAL OF SALMONELLA SPECIES IN RIVER WATER.
The survival of four Salmonella strains in river water microcosms was monitored using culturing techniques, direct counts, whole cell hybridization, scanning electron microscopy, and resuscitation techniques via the direct viable count method and flow cytrometry. Plate counts of...
SURVIVAL OF SALMONELLA SPECIES IN RIVER WATER
The survival of four Salmonella strains in river water microcosms was monitored by culturing techniques, direct counts, whole-cell hybridization, scanning electron microscopy, and resuscitation techniques via the direct viable count method and flow cytometry. Plate counts of bact...
Enumeration of Vibrio cholerae O1 in Bangladesh waters by fluorescent-antibody direct viable count.
Brayton, P R; Tamplin, M L; Huq, A; Colwell, R R
1987-01-01
A field trial to enumerate Vibrio cholerae O1 in aquatic environments in Bangladesh was conducted, comparing fluorescent-antibody direct viable count with culture detection by the most-probable-number index. Specificity of a monoclonal antibody prepared against the O1 antigen was assessed and incorporated into the fluorescence staining method. All pond and water samples yielded higher counts of viable V. cholerae O1 by fluorescent-antibody direct viable count than by the most-probable-number index. Fluorescence microscopy is a more sensitive detection system than culture methods because it allows the enumeration of both culturable and nonculturable cells and therefore provides more precise monitoring of microbiological water quality. PMID:3324967
Lisle, John T.; Hamilton, Martin A.; Willse, Alan R.; McFeters, Gordon A.
2004-01-01
Total direct counts of bacterial abundance are central in assessing the biomass and bacteriological quality of water in ecological and industrial applications. Several factors have been identified that contribute to the variability in bacterial abundance counts when using fluorescent microscopy, the most significant of which is retaining an adequate number of cells per filter to ensure an acceptable level of statistical confidence in the resulting data. Previous studies that have assessed the components of total-direct-count methods that contribute to this variance have attempted to maintain a bacterial cell abundance value per filter of approximately 106 cells filter-1. In this study we have established the lower limit for the number of bacterial cells per filter at which the statistical reliability of the abundance estimate is no longer acceptable. Our results indicate that when the numbers of bacterial cells per filter were progressively reduced below 105, the microscopic methods increasingly overestimated the true bacterial abundance (range, 15.0 to 99.3%). The solid-phase cytometer only slightly overestimated the true bacterial abundances and was more consistent over the same range of bacterial abundances per filter (range, 8.9 to 12.5%). The solid-phase cytometer method for conducting total direct counts of bacteria was less biased and performed significantly better than any of the microscope methods. It was also found that microscopic count data from counting 5 fields on three separate filters were statistically equivalent to data from counting 20 fields on a single filter.
Avian leucocyte counting using the hemocytometer
Dein, F.J.; Wilson, A.; Fischer, D.; Langenberg, P.
1994-01-01
Automated methods for counting leucocytes in avian blood are not available because of the presence of nucleated erythrocytes and thrombocytes. Therefore, total white blood cell counts are performed by hand using a hemocytometer. The Natt and Herrick and the Unopette methods are the most common stain and diluent preparations for this procedure. Replicate hemocytometer counts using these two methods were performed on blood from four birds of different species. Cells present in each square of the hemocytometer were counted. Counting cells in the corner, side, or center hemocytometer squares produced statistically equivalent results; counting four squares per chamber provided a result similar to that obtained by counting nine squares; and the Unopette method was more precise for hemocytometer counting than was the Natt and Herrick method. The Unopette method is easier to learn and perform but is an indirect process, utilizing the differential count from a stained smear. The Natt and Herrick method is a direct total count, but cell identification is more difficult.
NASA Astrophysics Data System (ADS)
Germino, Mary; Gallezot, Jean-Dominque; Yan, Jianhua; Carson, Richard E.
2017-07-01
Parametric images for dynamic positron emission tomography (PET) are typically generated by an indirect method, i.e. reconstructing a time series of emission images, then fitting a kinetic model to each voxel time activity curve. Alternatively, ‘direct reconstruction’, incorporates the kinetic model into the reconstruction algorithm itself, directly producing parametric images from projection data. Direct reconstruction has been shown to achieve parametric images with lower standard error than the indirect method. Here, we present direct reconstruction for brain PET using event-by-event motion correction of list-mode data, applied to two tracers. Event-by-event motion correction was implemented for direct reconstruction in the Parametric Motion-compensation OSEM List-mode Algorithm for Resolution-recovery reconstruction. The direct implementation was tested on simulated and human datasets with tracers [11C]AFM (serotonin transporter) and [11C]UCB-J (synaptic density), which follow the 1-tissue compartment model. Rigid head motion was tracked with the Vicra system. Parametric images of K 1 and distribution volume (V T = K 1/k 2) were compared to those generated by the indirect method by regional coefficient of variation (CoV). Performance across count levels was assessed using sub-sampled datasets. For simulated and real datasets at high counts, the two methods estimated K 1 and V T with comparable accuracy. At lower count levels, the direct method was substantially more robust to outliers than the indirect method. Compared to the indirect method, direct reconstruction reduced regional K 1 CoV by 35-48% (simulated dataset), 39-43% ([11C]AFM dataset) and 30-36% ([11C]UCB-J dataset) across count levels (averaged over regions at matched iteration); V T CoV was reduced by 51-58%, 54-60% and 30-46%, respectively. Motion correction played an important role in the dataset with larger motion: correction increased regional V T by 51% on average in the [11C]UCB-J dataset. Direct reconstruction of dynamic brain PET with event-by-event motion correction is achievable and dramatically more robust to noise in V T images than the indirect method.
Direct measurement of carbon-14 in carbon dioxide by liquid scintillation counting
NASA Technical Reports Server (NTRS)
Horrocks, D. L.
1969-01-01
Liquid scintillation counting technique is applied to the direct measurement of carbon-14 in carbon dioxide. This method has high counting efficiency and eliminates many of the basic problems encountered with previous techniques. The technique can be used to achieve a percent substitution reaction and is of interest as an analytical technique.
Fluorometric determination of the DNA concentration in municipal drinking water.
McCoy, W F; Olson, B H
1985-01-01
DNA concentrations in municipal drinking water samples were measured by fluorometry, using Hoechst 33258 fluorochrome. The concentration, extraction, and detection methods used were adapted from existing techniques. The method is reproducible, fast, accurate, and simple. The amounts of DNA per cell for five different bacterial isolates obtained from drinking water samples were determined by measuring DNA concentration and total cell concentration (acridine orange epifluorescence direct cell counting) in stationary pure cultures. The relationship between DNA concentration and epifluorescence total direct cell concentration in 11 different drinking water samples was linear and positive; the amounts of DNA per cell in these samples did not differ significantly from the amounts in pure culture isolates. We found significant linear correlations between DNA concentration and colony-forming unit concentration, as well as between epifluorescence direct cell counts and colony-forming unit concentration. DNA concentration measurements of municipal drinking water samples appear to monitor changes in bacteriological quality at least as well as total heterotrophic plate counting and epifluorescence direct cell counting. PMID:3890737
Dusick, Allison; Young, Karen M; Muir, Peter
2014-12-01
Canine osteoarthritis is a common disorder seen in veterinary clinical practice and causes considerable morbidity in dogs as they age. Synovial fluid analysis is an important tool for diagnosis and treatment of canine joint disease and obtaining a total nucleated cell count (TNCC) is particularly important. However, the low sample volumes obtained during arthrocentesis are often insufficient for performing an automated TNCC, thereby limiting diagnostic interpretation. The aim of the present study was to investigate whether estimation of TNCC in canine synovial fluid could be achieved by performing manual cell counts on direct smears of fluid. Fifty-eight synovial fluid samples, taken by arthrocentesis from 48 dogs, were included in the study. Direct smears of synovial fluid were prepared, and hyaluronidase added before cell counts were obtained using a commercial laser-based instrument. A protocol was established to count nucleated cells in a specific region of the smear, using a serpentine counting pattern; the mean number of nucleated cells per 400 × field was then calculated. There was a positive correlation between the automated TNCC and mean manual cell count, with more variability at higher TNCC. Regression analysis was performed to estimate TNCC from manual counts. By this method, 78% of the samples were correctly predicted to fall into one of three categories (within the reference interval, mildly to moderately increased, or markedly increased) relative to the automated TNCC. Intra-observer and inter-observer agreement was good to excellent. The results of the study suggest that interpretation of canine synovial fluid samples of low volume can be aided by methodical manual counting of cells on direct smears. Copyright © 2014 Elsevier Ltd. All rights reserved.
Martyniak, Brian; Bolton, Jason; Kuksin, Dmitry; Shahin, Suzanne M; Chan, Leo Li-Ying
2017-01-01
Brettanomyces spp. can present unique cell morphologies comprised of excessive pseudohyphae and budding, leading to difficulties in enumerating cells. The current cell counting methods include manual counting of methylene blue-stained yeasts or measuring optical densities using a spectrophotometer. However, manual counting can be time-consuming and has high operator-dependent variations due to subjectivity. Optical density measurement can also introduce uncertainties where instead of individual cells counted, an average of a cell population is measured. In contrast, by utilizing the fluorescence capability of an image cytometer to detect acridine orange and propidium iodide viability dyes, individual cell nuclei can be counted directly in the pseudohyphae chains, which can improve the accuracy and efficiency of cell counting, as well as eliminating the subjectivity from manual counting. In this work, two experiments were performed to demonstrate the capability of Cellometer image cytometer to monitor Brettanomyces concentrations, viabilities, and budding/pseudohyphae percentages. First, a yeast propagation experiment was conducted to optimize software counting parameters for monitoring the growth of Brettanomyces clausenii, Brettanomyces bruxellensis, and Brettanomyces lambicus, which showed increasing cell concentrations, and varying pseudohyphae percentages. The pseudohyphae formed during propagation were counted either as multiple nuclei or a single multi-nuclei organism, where the results of counting the yeast as a single multi-nuclei organism were directly compared to manual counting. Second, a yeast fermentation experiment was conducted to demonstrate that the proposed image cytometric analysis method can monitor the growth pattern of B. lambicus and B. clausenii during beer fermentation. The results from both experiments displayed different growth patterns, viability, and budding/pseudohyphae percentages for each Brettanomyces species. The proposed Cellometer image cytometry method can improve efficiency and eliminate operator-dependent variations of cell counting compared with the traditional methods, which can potentially improve the quality of beverage products employing Brettanomyces yeasts.
Watanabe, Taisuke; Isobe, Kazushige; Suzuki, Taiji; Kawabata, Hideo; Nakamura, Masayuki; Tsukioka, Tsuneyuki; Okudera, Toshimitsu; Okudera, Hajime; Uematsu, Kohya; Okuda, Kazuhiro; Nakata, Koh; Kawase, Tomoyuki
2017-01-01
Platelet concentrates should be quality-assured of purity and identity prior to clinical use. Unlike for the liquid form of platelet-rich plasma, platelet counts cannot be directly determined in solid fibrin clots and are instead calculated by subtracting the counts in other liquid or semi-clotted fractions from those in whole blood samples. Having long suspected the validity of this method, we herein examined the possible loss of platelets in the preparation process. Blood samples collected from healthy male donors were immediately centrifuged for advanced platelet-rich fibrin (A-PRF) and concentrated growth factors (CGF) according to recommended centrifugal protocols. Blood cells in liquid and semi-clotted fractions were directly counted. Platelets aggregated on clot surfaces were observed by scanning electron microscopy. A higher centrifugal force increased the numbers of platelets and platelet aggregates in the liquid red blood cell fraction and the semi-clotted red thrombus in the presence and absence of the anticoagulant, respectively. Nevertheless, the calculated platelet counts in A-PRF/CGF preparations were much higher than expected, rendering the currently accepted subtraction method inaccurate for determining platelet counts in fibrin clots. To ensure the quality of solid types of platelet concentrates chairside in a timely manner, a simple and accurate platelet-counting method should be developed immediately. PMID:29563413
2013-04-02
photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method to determine correlation between the two...study compared the non-specific, rapid photometric particle counting instrument, DustTrak, to the established OSHA modified NIOSH P&CAM 304 method...mask confidence training (27) . This study will compare a direct reading, non-specific photometric particle count instrument (DustTrak TSI Model
Di Schiavi, Maria Teresa; Foti, Marina; Mosconi, Maria Cristina; Mattiolo, Giuseppina; Cavallina, Roberta
2014-01-01
Irradiation is a preservation technology used to improve the safety and hygienic quality of food. Aim of this study was to assess the applicability and validity of the microbiological screening method direct epifluorescence filter technique (DEFT)/aerobic plate count (APC) (EN 13783:2001) for the identification of irradiated herbs and spices. Tests on non-irradiated and irradiated samples of dried herbs and spices were performed. The method was based on the comparison of APC and count obtained using DEFT. In accordance with the standard reference, this method is not applicable to samples with APC<103 colony forming units (CFU)/g and this is its main limit. The results obtained in our laboratories showed that in 50% of cases of non-irradiated samples and in 96% of the samples treated with ionising radiation, the method was not applicable due to a value of CFU/g <103. PMID:27800348
Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting.
Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay
2016-04-09
Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e(-) read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor.
Hybrid statistics-simulations based method for atom-counting from ADF STEM images.
De Wael, Annelies; De Backer, Annick; Jones, Lewys; Nellist, Peter D; Van Aert, Sandra
2017-06-01
A hybrid statistics-simulations based method for atom-counting from annular dark field scanning transmission electron microscopy (ADF STEM) images of monotype crystalline nanostructures is presented. Different atom-counting methods already exist for model-like systems. However, the increasing relevance of radiation damage in the study of nanostructures demands a method that allows atom-counting from low dose images with a low signal-to-noise ratio. Therefore, the hybrid method directly includes prior knowledge from image simulations into the existing statistics-based method for atom-counting, and accounts in this manner for possible discrepancies between actual and simulated experimental conditions. It is shown by means of simulations and experiments that this hybrid method outperforms the statistics-based method, especially for low electron doses and small nanoparticles. The analysis of a simulated low dose image of a small nanoparticle suggests that this method allows for far more reliable quantitative analysis of beam-sensitive materials. Copyright © 2017 Elsevier B.V. All rights reserved.
Hart, James L; Lang, Andrew C; Leff, Asher C; Longo, Paolo; Trevor, Colin; Twesten, Ray D; Taheri, Mitra L
2017-08-15
In many cases, electron counting with direct detection sensors offers improved resolution, lower noise, and higher pixel density compared to conventional, indirect detection sensors for electron microscopy applications. Direct detection technology has previously been utilized, with great success, for imaging and diffraction, but potential advantages for spectroscopy remain unexplored. Here we compare the performance of a direct detection sensor operated in counting mode and an indirect detection sensor (scintillator/fiber-optic/CCD) for electron energy-loss spectroscopy. Clear improvements in measured detective quantum efficiency and combined energy resolution/energy field-of-view are offered by counting mode direct detection, showing promise for efficient spectrum imaging, low-dose mapping of beam-sensitive specimens, trace element analysis, and time-resolved spectroscopy. Despite the limited counting rate imposed by the readout electronics, we show that both core-loss and low-loss spectral acquisition are practical. These developments will benefit biologists, chemists, physicists, and materials scientists alike.
Reduction of CMOS Image Sensor Read Noise to Enable Photon Counting
Guidash, Michael; Ma, Jiaju; Vogelsang, Thomas; Endsley, Jay
2016-01-01
Recent activity in photon counting CMOS image sensors (CIS) has been directed to reduction of read noise. Many approaches and methods have been reported. This work is focused on providing sub 1 e− read noise by design and operation of the binary and small signal readout of photon counting CIS. Compensation of transfer gate feed-through was used to provide substantially reduced CDS time and source follower (SF) bandwidth. SF read noise was reduced by a factor of 3 with this method. This method can be applied broadly to CIS devices to reduce the read noise for small signals to enable use as a photon counting sensor. PMID:27070625
High throughput single cell counting in droplet-based microfluidics.
Lu, Heng; Caen, Ouriel; Vrignon, Jeremy; Zonta, Eleonora; El Harrak, Zakaria; Nizard, Philippe; Baret, Jean-Christophe; Taly, Valérie
2017-05-02
Droplet-based microfluidics is extensively and increasingly used for high-throughput single-cell studies. However, the accuracy of the cell counting method directly impacts the robustness of such studies. We describe here a simple and precise method to accurately count a large number of adherent and non-adherent human cells as well as bacteria. Our microfluidic hemocytometer provides statistically relevant data on large populations of cells at a high-throughput, used to characterize cell encapsulation and cell viability during incubation in droplets.
Parthuisot, N.; Binet, M.; Touron-Bodilis, A.; Pougnard, C.; Lebaron, P.; Baudart, J.
2011-01-01
A new method was developed for the rapid and sensitive detection of viable Legionella pneumophila. The method combines specific immunofluorescence (IF) staining using monoclonal antibodies with a bacterial viability marker (ChemChrome V6 cellular esterase activity marker) by means of solid-phase cytometry (SPC). IF methods were applied to the detection and enumeration of both the total and viable L. pneumophila cells in water samples. The sensitivity of the IF methods coupled to SPC was 34 cells liter−1, and the reproducibility was good, with the coefficient of variation generally falling below 30%. IF methods were applied to the enumeration of total and viable L. pneumophila cells in 46 domestic hot water samples as well as in cooling tower water and natural water samples, such as thermal spring water and freshwater samples. Comparison with standard plate counts showed that (i) the total direct counts were always higher than the plate counts and (ii) the viable counts were higher than or close to the plate counts. With domestic hot waters, when the IF assay was combined with the viability test, SPC detected up to 3.4 × 103 viable but nonculturable L. pneumophila cells per liter. These direct IF methods could be a powerful tool for high-frequency monitoring of domestic hot waters or for investigating the occurrence of viable L. pneumophila in both man-made water systems and environmental water samples. PMID:21742913
NASA Technical Reports Server (NTRS)
Yu, F. P.; Pyle, B. H.; McFeters, G. A.
1993-01-01
This report describes the adaptation of an in situ direct viable count (in situ DVC) method in biofilm disinfection studies. The results obtained with this technique were compared to two other enumeration methods, the plate count (PC) and conventional direct viable count (c-DVC). An environmental isolate (Klebsiella pneumoniae Kp1) was used to form biofilms on stainless steel coupons in a stirred batch reactor. The in situ DVC method was applied to directly assess the viability of bacteria in biofilms without disturbing the integrity of the interfacial community. As additional advantages, the results were observed after 4 h instead of the 24 h incubation time required for colony formation and total cell numbers that remained on the substratum were enumerated. Chlorine and monochloramine were used to determine the susceptibilities of attached and planktonic bacteria to disinfection treatment using this novel analytical approach. The planktonic cells in the reactor showed no significant change in susceptibility to disinfectants during the period of biofilm formation. In addition, the attached cells did not reveal any more resistance to disinfection than planktonic cells. The disinfection studies of young biofilms indicated that 0.25 mg/l free chlorine (at pH 7.2) and 1 mg/l monochloramine (at pH 9.0) have comparable disinfection efficiencies at 25 degrees C. Although being a weaker disinfectant, monochloramine was more effective in removing attached bacteria from the substratum than free chlorine. The in situ DVC method always showed at least one log higher viable cell densities than the PC method, suggesting that the in situ DVC method is more efficient in the enumeration of biofilm bacteria. The results also indicated that the in situ DVC method can provide more accurate information regarding the cell numbers and viability of bacteria within biofilms following disinfection.
The topology of galaxy clustering.
NASA Astrophysics Data System (ADS)
Coles, P.; Plionis, M.
The authors discuss an objective method for quantifying the topology of the galaxy distribution using only projected galaxy counts. The method is a useful complement to fully three-dimensional studies of topology based on the genus by virtue of the enormous projected data sets available. Applying the method to the Lick counts they find no evidence for large-scale non-gaussian behaviour, whereas the small-scale distribution is strongly non-gaussian, with a shift in the meatball direction.
Physiological responses of bacteria in biofilms to disinfection.
Yu, F P; McFeters, G A
1994-01-01
In situ enumeration methods using fluorescent probes and a radioisotope labelling technique were applied to evaluate physiological changes of Klebsiella pneumoniae within biofilms after disinfection treatment. Chlorine (0.25 mg of free chlorine per liter [pH 7.2]) and monochloramine (1 mg/liter [pH 9.0]) were employed as disinfectants in the study. Two fluorgenic compounds, 5-cyano-2,3-ditolyl tetrazolium chloride and rhodamine 123, and tritiated uridine incorporation were chosen for assessment of physiological activities. Results obtained by these methods were compared with those from the plate count and direct viable count methods. 5-Cyano-2,3-ditolyl tetrazolium chloride is an indicator of bacterial respiratory activity, rhodamine 123 is incorporated into bacteria in response to transmembrane potential, and the incorporation of uridine represents the global RNA turnover rate. The results acquired by these methods following disinfection exposure showed a range of responses and suggested different physiological reactions in biofilms exposed to chlorine and monochloramine. The direct viable count response and respiratory activity were affected more by disinfection than were the transmembrane potential and RNA turnover rate on the basis of comparable efficiency as evaluated by plate count enumeration. Information revealed by these approaches can provide different physiological insights that may be used in evaluating the efficacy of biofilm disinfection. PMID:8074525
Method and apparatus for measuring enrichment of UF6
Hill, Thomas Roy [Santa Fe, NM; Ianakiev, Kiril Dimitrov [Los Alamos, NM
2011-06-07
A system and method are disclosed for determining the enrichment of .sup.235U in Uranium Hexafluoride (UF6) utilizing synthesized X-rays which are directed at a container test zone containing a sample of UF6. A detector placed behind the container test zone then detects and counts the X-rays which pass through the container and the UF6. In order to determine the portion of the attenuation due to the UF6 gas alone, this count rate may then be compared to a calibration count rate of X-rays passing through a calibration test zone which contains a vacuum, the test zone having experienced substantially similar environmental conditions as the actual test zone. Alternatively, X-rays of two differing energy levels may be alternately directed at the container, where either the container or the UF6 has a high sensitivity to the difference in the energy levels, and the other having a low sensitivity.
Zhang, Hui; Guo, Peixuan
2014-05-15
Direct counting of biomolecules within biological complexes or nanomachines is demanding. Single molecule counting using optical microscopy is challenging due to the diffraction limit. The single molecule photobleaching (SMPB) technology for direct counting developed by our team (Shu et al., 2007 [18]; Zhang et al., 2007 [19]) offers a simple and straightforward method to determine the stoichiometry of molecules or subunits within biocomplexes or nanomachines at nanometer scales. Stoichiometry is determined by real-time observation of the number of descending steps resulted from the photobleaching of individual fluorophore. This technology has now been used extensively for single molecule counting of protein, RNA, and other macromolecules in a variety of complexes or nanostructures. Here, we elucidate the SMPB technology, using the counting of RNA molecules within a bacteriophage phi29 DNA-packaging biomotor as an example. The method described here can be applied to the single molecule counting of other molecules in other systems. The construction of a concise, simple and economical single molecule total internal reflection fluorescence (TIRF) microscope combining prism-type and objective-type TIRF is described. The imaging system contains a deep-cooled sensitive EMCCD camera with single fluorophore detection sensitivity, a laser combiner for simultaneous dual-color excitation, and a Dual-View™ imager to split the multiple outcome signals to different detector channels based on their wavelengths. Methodology of the single molecule photobleaching assay used to elucidate the stoichiometry of RNA on phi29 DNA packaging motor and the mechanism of protein/RNA interaction are described. Different methods for single fluorophore labeling of RNA molecules are reviewed. The process of statistical modeling to reveal the true copy number of the biomolecules based on binomial distribution is also described. Copyright © 2014 Elsevier Inc. All rights reserved.
Christie, J; Schwan, E V; Bodenstein, L L; Sommerville, J E M; van der Merwe, L L
2011-06-01
Several faecal examination techniques have shown variable sensitivity in demonstrating Spirocerca lupi (S. lupi) eggs. The objective of this study was to determine which faecal examination technique, including a novel modified centrifugal flotation technique, was most sensitive to diagnose spirocercosis. Ten coproscopic examinations were performed on faeces collected from 33 dogs confirmed endoscopically to have spirocercosis. The tests included a direct faecal examination, a faecal sedimentation/flotation test, 4 direct faecal flotations and 4 modified faecal centrifugal flotations. These latter 2 flotation tests utilised 4 different faecal flotation solutions: NaNO3 (SG 1.22), MgSO4 (SG 1.29), ZnSO4 (SG 1.30) and sugar (SG 1.27). The sensitivity of the tests ranged between 42% and 67%, with the NaNO3 solution showing the highest sensitivity in both the direct and modified-centrifugal flotations. The modified NaNO3 centrifugal method ranked 1st with the highest mean egg count (45.24 +/- 83), and was superior (i.e. higher egg count) and significantly different (P < 0.05) compared with the routine saturated sugar, ZnSO4 and MgSO4 flotation methods. The routine NaNO3 flotation method was also superior and significantly different (P < 0.05) compared with the routine ZnSO4 and MgSO4 flotation methods. Fifteen per cent (n = 5) of dogs had neoplastic oesophageal nodules and a further 18% (n = 6) had both neoplastic and non-neoplastic nodules. S. lupi eggs were demonstrated in 40% of dogs with neoplastic nodules only and 72.9% of the dogs with non-neoplastic nodules. The mean egg count in the non-neoplastic group (61) was statistically greater (P = 0.02) than that of the neoplastic group (1). The results show that faecal examination using a NaNO3 solution is the most sensitive in the diagnosis of spirocercosis. The modified centrifugal flotation faecal method using this solution has the highest egg count. The study also found that dogs with neoplastic nodules shed significantly fewer eggs than dogs with non-neoplastic nodules.
Improved Method for Determination of Respiring Individual Microorganisms in Natural Waters
Tabor, Paul S.; Neihof, Rex A.
1982-01-01
A method is reported that combines the microscopic determinations of specific, individual, respiring microorganisms by the detection of electron transport system activity and the total number of organisms of an estuarine population by epifluorescence microscopy. An active cellular electron transport system specifically reduces 2-(p-iodophenyl)-3-(p-nitrophenyl)-5-phenyl tetrazolium chloride (INT) to INT-formazan, which is recognized as opaque intracellular deposits in microorganisms stained with acridine orange. In a comparison of previously described sample preparation techniques, a loss of >70% of the counts of INT-reducing microorganisms was shown to be due to the dissolution of INT-formazan deposits by immersion oil (used in microscopy). In addition, significantly fewer fluorescing microorganisms and INT-formazan deposits, both ≤0.2 μm in size, were found for sample preparations that included a Nuclepore filter. Visual clarity was enhanced, and significantly greater direct counts and counts of INT-reducing microorganisms were recognized by transferring microorganisms from a filter to a gelatin film on a cover glass, followed by coating the sample with additional gelatin to produce a transparent matrix. With this method, the number of INT-reducing microorganisms determined for a Chesapeake Bay water sample was 2-to 10-fold greater than the number of respiring organisms reported previously for marine or freshwater samples. INT-reducing microorganisms constituted 61% of the total direct counts determined for a Chesapeake Bay water sample. This is the highest percentage of metabolically active microorganisms of any aquatic population reported using a method which determines both total counts and specific activity. PMID:16346025
Improved method for determination of respiring individual microorganisms in natural waters.
Tabor, P S; Neihof, R A
1982-06-01
A method is reported that combines the microscopic determinations of specific, individual, respiring microorganisms by the detection of electron transport system activity and the total number of organisms of an estuarine population by epifluorescence microscopy. An active cellular electron transport system specifically reduces 2-(p-iodophenyl)-3-(p-nitrophenyl)-5-phenyl tetrazolium chloride (INT) to INT-formazan, which is recognized as opaque intracellular deposits in microorganisms stained with acridine orange. In a comparison of previously described sample preparation techniques, a loss of >70% of the counts of INT-reducing microorganisms was shown to be due to the dissolution of INT-formazan deposits by immersion oil (used in microscopy). In addition, significantly fewer fluorescing microorganisms and INT-formazan deposits, both =0.2 mum in size, were found for sample preparations that included a Nuclepore filter. Visual clarity was enhanced, and significantly greater direct counts and counts of INT-reducing microorganisms were recognized by transferring microorganisms from a filter to a gelatin film on a cover glass, followed by coating the sample with additional gelatin to produce a transparent matrix. With this method, the number of INT-reducing microorganisms determined for a Chesapeake Bay water sample was 2-to 10-fold greater than the number of respiring organisms reported previously for marine or freshwater samples. INT-reducing microorganisms constituted 61% of the total direct counts determined for a Chesapeake Bay water sample. This is the highest percentage of metabolically active microorganisms of any aquatic population reported using a method which determines both total counts and specific activity.
Test of a mosquito eggshell isolation method and subsampling procedure.
Turner, P A; Streever, W J
1997-03-01
Production of Aedes vigilax, the common salt-marsh mosquito, can be assessed by determining eggshell densities found in soil. In this study, 14 field-collected eggshell samples were used to test a subsampling technique and compare eggshell counts obtained with a flotation method to those obtained by direct examination of sediment (DES). Relative precision of the subsampling technique was assessed by determining the minimum number of subsamples required to estimate the true mean and confidence interval of a sample at a predetermined confidence level. A regression line was fitted to cube-root transformed eggshell counts obtained from flotation and DES and found to be significant (P < 0.001, r2 = 0.97). The flotation method allowed processing of samples in about one-third of the time required by DES, but recovered an average of 44% of the eggshells present. Eggshells obtained with the flotation method can be used to predict those from DES using the following equation: DES count = [1.386 x (flotation count)0.33 - 0.01]3.
Modification of Point Counts for Surveying Cropland Birds
Kathryn Freemark; Catherine Rogers
1995-01-01
As part of a comparative study of agricultural impacts on wildlife, modifications to the point count method were evaluated for surveying birds in, and adjacent to, cropland during the breeding season (May to early July) in Ontario. Location in the field, observation direction and distance, number of visits, and number of study sites per farm were examined using point...
Direct reading of electrocardiograms and respiration rates
NASA Technical Reports Server (NTRS)
Wise, J. P.
1969-01-01
Technique for reading heart and respiration rates is more accurate and direct than the previous method. Index of a plastic calibrated card is aligned with a point on the electrocardiogram. Complexes are counted as indicated on the card and heart or respiration rate is read directly from the appropriate scale.
Limberg, Brian J; Johnstone, Kevin; Filloon, Thomas; Catrenich, Carl
2016-09-01
Using United States Pharmacopeia-National Formulary (USP-NF) general method <1223> guidance, the Soleris(®) automated system and reagents (Nonfermenting Total Viable Count for bacteria and Direct Yeast and Mold for yeast and mold) were validated, using a performance equivalence approach, as an alternative to plate counting for total microbial content analysis using five representative microbes: Staphylococcus aureus, Bacillus subtilis, Pseudomonas aeruginosa, Candida albicans, and Aspergillus brasiliensis. Detection times (DTs) in the alternative automated system were linearly correlated to CFU/sample (R(2) = 0.94-0.97) with ≥70% accuracy per USP General Chapter <1223> guidance. The LOD and LOQ of the automated system were statistically similar to the traditional plate count method. This system was significantly more precise than plate counting (RSD 1.2-2.9% for DT, 7.8-40.6% for plate counts), was statistically comparable to plate counting with respect to variations in analyst, vial lots, and instruments, and was robust when variations in the operating detection thresholds (dTs; ±2 units) were used. The automated system produced accurate results, was more precise and less labor-intensive, and met or exceeded criteria for a valid alternative quantitative method, consistent with USP-NF general method <1223> guidance.
Evaluation of seven aquatic sampling methods for amphibians and other aquatic fauna
Gunzburger, M.S.
2007-01-01
To design effective and efficient research and monitoring programs researchers must have a thorough understanding of the capabilities and limitations of their sampling methods. Few direct comparative studies exist for aquatic sampling methods for amphibians. The objective of this study was to simultaneously employ seven aquatic sampling methods in 10 wetlands to compare amphibian species richness and number of individuals detected with each method. Four sampling methods allowed counts of individuals (metal dipnet, D-frame dipnet, box trap, crayfish trap), whereas the other three methods allowed detection of species (visual encounter, aural, and froglogger). Amphibian species richness was greatest with froglogger, box trap, and aural samples. For anuran species, the sampling methods by which each life stage was detected was related to relative length of larval and breeding periods and tadpole size. Detection probability of amphibians varied across sampling methods. Box trap sampling resulted in the most precise amphibian count, but the precision of all four count-based methods was low (coefficient of variation > 145 for all methods). The efficacy of the four count sampling methods at sampling fish and aquatic invertebrates was also analyzed because these predatory taxa are known to be important predictors of amphibian habitat distribution. Species richness and counts were similar for fish with the four methods, whereas invertebrate species richness and counts were greatest in box traps. An effective wetland amphibian monitoring program in the southeastern United States should include multiple sampling methods to obtain the most accurate assessment of species community composition at each site. The combined use of frogloggers, crayfish traps, and dipnets may be the most efficient and effective amphibian monitoring protocol. ?? 2007 Brill Academic Publishers.
Guarddon, Mónica; Miranda, Jose M; Vázquez, Beatriz I; Cepeda, Alberto; Franco, Carlos M
2012-07-01
The evolution of antimicrobial-resistant bacteria has become a threat to food safety and methods to control them are necessary. Counts of tetracycline-resistant (TR) bacteria by microbiological methods were compared with those obtained by quantitative PCR (qPCR) in 80 meat samples. TR Enterobacteriaceae counts were similar between the count plate method and qPCR (P= 0.24), whereas TR aerobic mesophilic bacteria counts were significantly higher by the microbiological method (P < 0.001). The distribution of tetA and tetB genes was investigated in different types of meat. tetA was detected in chicken meat (40%), turkey meat (100%), pork (20%), and beef (40%) samples, whereas tetB was detected in chicken meat (45%), turkey meat (70%), pork (30%), and beef (35%) samples. The presence of tetracycline residues was also investigated by a receptor assay. This study offers an alternative and rapid method for monitoring the presence of TR bacteria in meat and furthers the understanding of the distribution of tetA and tetB genes. © 2012 Institute of Food Technologists®
Raman scattering method and apparatus for measuring isotope ratios and isotopic abundances
Harney, Robert C.; Bloom, Stewart D.
1978-01-01
Raman scattering is used to measure isotope ratios and/or isotopic abundances. A beam of quasi-monochromatic photons is directed onto the sample to be analyzed, and the resulting Raman-scattered photons are detected and counted for each isotopic species of interest. These photon counts are treated mathematically to yield the desired isotope ratios or isotopic abundances.
In situ detection of warfarin using time-correlated single-photon counting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Rosengren, Annika M.; Karlsson, Bjoern C.G.; Naeslund, Inga
Highlights: {yields} Direct in situ measurement of specific isomeric forms of the anticoagulant warfarin. {yields} TCSPC spectroscopy in conjunction with synthetic Sudlow I binding site receptors. {yields} Development of sensor principle for use in clinical and environmental monitoring. -- Abstract: Here we report on a novel method for the direct in situ measurement of specific isomeric forms of the anticoagulant warfarin using time correlated single-photon counting (TCSPC) spectroscopy in conjunction with synthetic Sudlow I binding site receptors. The method is highly robust over the clinically significant concentration range, and demonstrates the potential of the binding site mimics in conjunction withmore » the spectroscopic strategy employed here for the determination of this important pharmaceutical in clinical or even environmental samples.« less
[Factors affecting the DAPI fluorescence direct count in the tidal river sediment].
Chen, Chen; Huang, Shan; Wu, Qun-he; Li, Rui-yi; Zhang, Ren-duo
2010-08-01
The factors affecting the DAPI (4', 6-diamidino-2-phenylidole) fluorescence direct count in the tidal river sediment were examined. Sediment samples were collected from the Guangzhou section of the Pearl River. Besides sediment texture and organic matter, an improved staining procedure and the involved parameters were analyzed. Results showed that the procedure with the sediment with 2000 fold dilution and ultrasonic water bath for 10 min, and with a final DAPI concentration of 10 microg x mL(-1) and staining time for more than 30 min produced the optimum results of DAPI direct count in the sediment. The total bacterial number was correlated to the proportion of the non-nucleoid-containing cells to the total bacterial number (r = 0.587, p = 0.004). The organic matter content also correlated to the ration. The clay content had a strong correlation with the organic matter, through which the clay content also affected the ratio. A multiple regression analysis between the ration versus the organic matter, the total bacterial number, and the clay content showed that the regression equation fit the measure values satisfactorily (r = 0.694). These results indicated that the above factors needed to be considered in the applications of the DAPI fluorescence direct counting method to the tidal river sediment.
Comparison of epifluorescent viable bacterial count methods
NASA Technical Reports Server (NTRS)
Rodgers, E. B.; Huff, T. L.
1992-01-01
Two methods, the 2-(4-Iodophenyl) 3-(4-nitrophenyl) 5-phenyltetrazolium chloride (INT) method and the direct viable count (DVC), were tested and compared for their efficiency for the determination of the viability of bacterial populations. Use of the INT method results in the formation of a dark spot within each respiring cell. The DVC method results in elongation or swelling of growing cells that are rendered incapable of cell division. Although both methods are subjective and can result in false positive results, the DVC method is best suited to analysis of waters in which the number of different types of organisms present in the same sample is assumed to be small, such as processed waters. The advantages and disadvantages of each method are discussed.
Excreta Sampling as an Alternative to In Vivo Measurements at the Hanford Site.
Carbaugh, Eugene H; Antonio, Cheryl L; Lynch, Timothy P
2015-08-01
The capabilities of indirect radiobioassay by urine and fecal sample analysis were compared with the direct radiobioassay methods of whole body counting and lung counting for the most common radionuclides and inhalation exposure scenarios encountered by Hanford workers. Radionuclides addressed by in vivo measurement included 137Cs, 60Co, 154Eu, and 241Am as an indicator for plutonium mixtures. The same radionuclides were addressed using gamma energy analysis of urine samples, augmented by radiochemistry and alpha spectrometry methods for plutonium in urine and fecal samples. It was concluded that in vivo whole body counting and lung counting capability should be maintained at the Hanford Site for the foreseeable future, however, urine and fecal sample analysis could provide adequate, though degraded, monitoring capability for workers as a short-term alternative, should in vivo capability be lost due to planned or unplanned circumstances.
Wedge sampling for computing clustering coefficients and triangle counts on large graphs
Seshadhri, C.; Pinar, Ali; Kolda, Tamara G.
2014-05-08
Graphs are used to model interactions in a variety of contexts, and there is a growing need to quickly assess the structure of such graphs. Some of the most useful graph metrics are based on triangles, such as those measuring social cohesion. Despite the importance of these triadic measures, algorithms to compute them can be extremely expensive. We discuss the method of wedge sampling. This versatile technique allows for the fast and accurate approximation of various types of clustering coefficients and triangle counts. Furthermore, these techniques are extensible to counting directed triangles in digraphs. Our methods come with provable andmore » practical time-approximation tradeoffs for all computations. We provide extensive results that show our methods are orders of magnitude faster than the state of the art, while providing nearly the accuracy of full enumeration.« less
García-Hernández, J; Moreno, Y; Amorocho, C M; Hernández, M
2012-03-01
We have developed a direct viable count (DVC)-FISH procedure for quickly and easily discriminating between viable and nonviable cells of Lactobacillus delbrueckii subsp. bulgaricus and Streptococcus thermophilus strains, the traditional yogurt bacteria. direct viable count method has been modified and adapted for Lact. delbrueckii subsp. bulgaricus and Strep. thermophilus analysis by testing different times of incubation and concentrations of DNA-gyrase inhibitors. DVC procedure has been combined with fluorescent in situ hybridization (FISH) for the specific detection of viable cells of both bacteria with specific rRNA oligonucleotide probes (DVC-FISH). Of the four antibiotics tested (novobiocin, nalidixic acid, pipemidic acid and ciprofloxacin), novobiocin was the most effective for DVC method and the optimum incubation time was 7 h for both bacteria. The number of viable cells was obtained by the enumeration of specific hybridized cells that were elongated at least twice their original length for Lactobacillus and twice their original size for Streptococcus. This technique was successfully applied to detect viable cells in inoculated faeces. Results showed that this DVC-FISH procedure is a quick and culture-independent useful method to specifically detect viable Lact. delbrueckii subsp. bulgaricus and Strep. thermophilus in different samples, being applied for the first time to lactic acid bacteria. © 2011 The Authors. Letters in Applied Microbiology © 2011 The Society for Applied Microbiology.
4D light-field sensing system for people counting
NASA Astrophysics Data System (ADS)
Hou, Guangqi; Zhang, Chi; Wang, Yunlong; Sun, Zhenan
2016-03-01
Counting the number of people is still an important task in social security applications, and a few methods based on video surveillance have been proposed in recent years. In this paper, we design a novel optical sensing system to directly acquire the depth map of the scene from one light-field camera. The light-field sensing system can count the number of people crossing the passageway, and record the direction and intensity of rays at a snapshot without any assistant light devices. Depth maps are extracted from the raw light-ray sensing data. Our smart sensing system is equipped with a passive imaging sensor, which is able to naturally discern the depth difference between the head and shoulders for each person. Then a human model is built. Through detecting the human model from light-field images, the number of people passing the scene can be counted rapidly. We verify the feasibility of the sensing system as well as the accuracy by capturing real-world scenes passing single and multiple people under natural illumination.
Analysis of Texture Using the Fractal Model
NASA Technical Reports Server (NTRS)
Navas, William; Espinosa, Ramon Vasquez
1997-01-01
Properties such as the fractal dimension (FD) can be used for feature extraction and classification of regions within an image. The FD measures the degree of roughness of a surface, so this number is used to characterize a particular region, in order to differentiate it from another. There are two basic approaches discussed in the literature to measure FD: the blanket method, and the box counting method. Both attempt to measure FD by estimating the change in surface area with respect to the change in resolution. We tested both methods but box counting resulted computationally faster and gave better results. Differential Box Counting (DBC) was used to segment a collage containing three textures. The FD is independent of directionality and brightness so five features were used derived from the original image to account for directionality and gray level biases. FD can not be measured on a point, so we use a window that slides across the image giving values of FD to the pixel on the center of the window. Windowing blurs the boundaries of adjacent classes, so an edge-preserving, feature-smoothing algorithm is used to improve classification within segments and to make the boundaries sharper. Segmentation using DBC was 90.8910 accurate.
Wilson, Brooke H; Cole, Brian J; Goodale, Margaret B; Fortier, Lisa A
2018-04-01
The aim of this study was to provide clinical recommendations about the use of platelet-rich plasma (PRP) that was subjected to short-term storage at room temperature. We determined bioactive growth factor and cytokine concentrations as indicators of platelet and white blood cell degranulation in blood and PRP. Additionally, this study sought to validate the use of manual, direct smear analysis as an alternative to automated methods for platelet quantification in PRP. Blood was used to generate low-leukocyte PRP (Llo PRP) or high-leukocyte PRP (Lhi PRP). Blood was either processed immediately or kept at room temperature for 2 or 4 hours prior to generation of PRP, which was then held at room temperature for 0, 1, 2, or 4 hours. Subsequently, bioactive transforming growth factor beta-1 and matrix metalloproteinase-9 were measured by ELISA (enzyme-linked immunosorbent assay). Manual and automated platelet counts were performed on all blood and PRP samples. There were no differences in growth factor or cytokine concentration when blood or Llo PRP or Lhi PRP was retained at room temperature for up to 4 hours. Manual, direct smear analysis for platelet quantification was not different from the use of automated machine counting for PRP samples, but in the starting blood samples, manual platelet counts were significantly higher than those generated using automated technology. When there is a delay of up to 4 hours in the generation of PRP from blood or in the application of PRP to the patient, bioactive growth factor and cytokine concentrations remain stable in both blood and PRP. A manual direct counting method is a simple, cost-effective, and valid method to measure the contents of the PRP product being delivered to the patient.
Göbel, Silke M
2015-01-01
Most adults and children in cultures where reading text progresses from left to right also count objects from the left to the right side of space. The reverse is found in cultures with a right-to-left reading direction. The current set of experiments investigated whether vertical counting in the horizontal plane is also influenced by reading direction. Participants were either from a left-to-right reading culture (UK) or from a mixed (left-to-right and top-to-bottom) reading culture (Hong Kong). In Experiment 1, native English-speaking children and adults and native Cantonese-speaking children and adults performed three object counting tasks. Objects were presented flat on a table in a horizontal, vertical, and square display. Independent of culture, the horizontal array was mostly counted from left to right. While the majority of English-speaking children counted the vertical display from bottom to top, the majority of the Cantonese-speaking children as well as both Cantonese- and English-speaking adults counted the vertical display from top to bottom. This pattern was replicated in the counting pattern for squares: all groups except the English-speaking children started counting with the top left coin. In Experiment 2, Cantonese-speaking adults counted a square array of objects after they read a text presented to them either in left-to-right or in top-to-bottom reading direction. Most Cantonese-speaking adults started counting the array by moving horizontally from left to right. However, significantly more Cantonese-speaking adults started counting with a top-to-bottom movement after reading the text presented in a top-to-bottom reading direction than in a left-to-right reading direction. Our results show clearly that vertical counting in the horizontal plane is influenced by longstanding as well as more recent experience of reading direction.
Marginalized zero-altered models for longitudinal count data.
Tabb, Loni Philip; Tchetgen, Eric J Tchetgen; Wellenius, Greg A; Coull, Brent A
2016-10-01
Count data often exhibit more zeros than predicted by common count distributions like the Poisson or negative binomial. In recent years, there has been considerable interest in methods for analyzing zero-inflated count data in longitudinal or other correlated data settings. A common approach has been to extend zero-inflated Poisson models to include random effects that account for correlation among observations. However, these models have been shown to have a few drawbacks, including interpretability of regression coefficients and numerical instability of fitting algorithms even when the data arise from the assumed model. To address these issues, we propose a model that parameterizes the marginal associations between the count outcome and the covariates as easily interpretable log relative rates, while including random effects to account for correlation among observations. One of the main advantages of this marginal model is that it allows a basis upon which we can directly compare the performance of standard methods that ignore zero inflation with that of a method that explicitly takes zero inflation into account. We present simulations of these various model formulations in terms of bias and variance estimation. Finally, we apply the proposed approach to analyze toxicological data of the effect of emissions on cardiac arrhythmias.
Marginalized zero-altered models for longitudinal count data
Tabb, Loni Philip; Tchetgen, Eric J. Tchetgen; Wellenius, Greg A.; Coull, Brent A.
2015-01-01
Count data often exhibit more zeros than predicted by common count distributions like the Poisson or negative binomial. In recent years, there has been considerable interest in methods for analyzing zero-inflated count data in longitudinal or other correlated data settings. A common approach has been to extend zero-inflated Poisson models to include random effects that account for correlation among observations. However, these models have been shown to have a few drawbacks, including interpretability of regression coefficients and numerical instability of fitting algorithms even when the data arise from the assumed model. To address these issues, we propose a model that parameterizes the marginal associations between the count outcome and the covariates as easily interpretable log relative rates, while including random effects to account for correlation among observations. One of the main advantages of this marginal model is that it allows a basis upon which we can directly compare the performance of standard methods that ignore zero inflation with that of a method that explicitly takes zero inflation into account. We present simulations of these various model formulations in terms of bias and variance estimation. Finally, we apply the proposed approach to analyze toxicological data of the effect of emissions on cardiac arrhythmias. PMID:27867423
Cardiac-gated parametric images from 82 Rb PET from dynamic frames and direct 4D reconstruction.
Germino, Mary; Carson, Richard E
2018-02-01
Cardiac perfusion PET data can be reconstructed as a dynamic sequence and kinetic modeling performed to quantify myocardial blood flow, or reconstructed as static gated images to quantify function. Parametric images from dynamic PET are conventionally not gated, to allow use of all events with lower noise. An alternative method for dynamic PET is to incorporate the kinetic model into the reconstruction algorithm itself, bypassing the generation of a time series of emission images and directly producing parametric images. So-called "direct reconstruction" can produce parametric images with lower noise than the conventional method because the noise distribution is more easily modeled in projection space than in image space. In this work, we develop direct reconstruction of cardiac-gated parametric images for 82 Rb PET with an extension of the Parametric Motion compensation OSEM List mode Algorithm for Resolution-recovery reconstruction for the one tissue model (PMOLAR-1T). PMOLAR-1T was extended to accommodate model terms to account for spillover from the left and right ventricles into the myocardium. The algorithm was evaluated on a 4D simulated 82 Rb dataset, including a perfusion defect, as well as a human 82 Rb list mode acquisition. The simulated list mode was subsampled into replicates, each with counts comparable to one gate of a gated acquisition. Parametric images were produced by the indirect (separate reconstructions and modeling) and direct methods for each of eight low-count and eight normal-count replicates of the simulated data, and each of eight cardiac gates for the human data. For the direct method, two initialization schemes were tested: uniform initialization, and initialization with the filtered iteration 1 result of the indirect method. For the human dataset, event-by-event respiratory motion compensation was included. The indirect and direct methods were compared for the simulated dataset in terms of bias and coefficient of variation as a function of iteration. Convergence of direct reconstruction was slow with uniform initialization; lower bias was achieved in fewer iterations by initializing with the filtered indirect iteration 1 images. For most parameters and regions evaluated, the direct method achieved the same or lower absolute bias at matched iteration as the indirect method, with 23%-65% lower noise. Additionally, the direct method gave better contrast between the perfusion defect and surrounding normal tissue than the indirect method. Gated parametric images from the human dataset had comparable relative performance of indirect and direct, in terms of mean parameter values per iteration. Changes in myocardial wall thickness and blood pool size across gates were readily visible in the gated parametric images, with higher contrast between myocardium and left ventricle blood pool in parametric images than gated SUV images. Direct reconstruction can produce parametric images with less noise than the indirect method, opening the potential utility of gated parametric imaging for perfusion PET. © 2017 American Association of Physicists in Medicine.
Counting the number of Feynman graphs in QCD
NASA Astrophysics Data System (ADS)
Kaneko, T.
2018-05-01
Information about the number of Feynman graphs for a given physical process in a given field theory is especially useful for confirming the result of a Feynman graph generator used in an automatic system of perturbative calculations. A method of counting the number of Feynman graphs with weight of symmetry factor was established based on zero-dimensional field theory, and was used in scalar theories and QED. In this article this method is generalized to more complicated models by direct calculation of generating functions on a computer algebra system. This method is applied to QCD with and without counter terms, where many higher order are being calculated automatically.
Storm, Daniel J.; Samuel, Michael D.; Van Deelen, Timothy R.; Malcolm, Karl D.; Rolley, Robert E.; Frost, Nancy A.; Bates, Donald P.; Richards, Bryan J.
2011-01-01
Aerial surveys using direct counts of animals are commonly used to estimate deer abundance. Forward-looking infrared (FLIR) technology is increasingly replacing traditional methods such as visual observation from helicopters. Our goals were to compare fixed-wing FLIR and visual, helicopter-based counts in terms of relative bias, influence of snow cover and cost. We surveyed five plots: four 41.4 km2 plots with free-ranging white-tailed deer Odocoileus virginianus populations in Wisconsin and a 5.3 km2 plot with a white-tailed deer population contained by a high fence in Michigan. We surveyed plots using both fixed-wing FLIR and helicopters, both with snow cover and without snow. None of the methods counted more deer than the other when snow was present. Helicopter counts were lower in the absence of snow, but lack of snow cover did not apparently affect FLIR. Group sizes of observed deer were similar regardless of survey method or season. We found that FLIR counts were generally precise (CV = 0.089) when two or three replicate surveys were conducted within a few hours. However, at the plot level, FLIR counts differed greatly between seasons, suggesting that detection rates vary over larger time scales. Fixed-wing FLIR was more costly than visual observers in helicopters and was more restrictive in terms of acceptable survey conditions. Further research is needed to understand what factors influence the detection of deer during FLIR surveys.
NASA Astrophysics Data System (ADS)
Araújo, M. M.; Duarte, R. C.; Silva, P. V.; Marchioni, E.; Villavicencio, A. L. C. H.
2009-07-01
Marketing of minimally processed vegetables (MPV) are gaining impetus due to its convenience, freshness and apparent health effect. However, minimal processing does not reduce pathogenic microorganisms to safe levels. Food irradiation is used to extend the shelf life and to inactivate food-borne pathogens. In combination with minimal processing it could improve safety and quality of MPV. A microbiological screening method based on the use of direct epifluorescent filter technique (DEFT) and aerobic plate count (APC) has been established for the detection of irradiated foodstuffs. The aim of this study was to evaluate the applicability of this technique in detecting MPV irradiation. Samples from retail markets were irradiated with 0.5 and 1.0 kGy using a 60Co facility. In general, with a dose increment, DEFT counts remained similar independent of the irradiation while APC counts decreased gradually. The difference of the two counts gradually increased with dose increment in all samples. It could be suggested that a DEFT/APC difference over 2.0 log would be a criteria to judge if a MPV was treated by irradiation. The DEFT/APC method could be used satisfactorily as a screening method for indicating irradiation processing.
ERIC Educational Resources Information Center
Shaki, Samuel; Fischer, Martin H.; Gobel, Silke M.
2012-01-01
Western adults associate small numbers with left space and large numbers with right space. Where does this pervasive spatial-numerical association come from? In this study, we first recorded directional counting preferences in adults with different reading experiences (left to right, right to left, mixed, and illiterate) and observed a clear…
Development of spatial preferences for counting and picture naming.
Knudsen, Birgit; Fischer, Martin H; Aschersleben, Gisa
2015-11-01
The direction of object enumeration reflects children's enculturation but previous work on the development of such spatial preferences has been inconsistent. Therefore, we documented directional preferences in finger counting, object counting, and picture naming for children (4 groups from 3 to 6 years, N = 104) and adults (N = 56). We found a right-side preference for finger counting in 3- to 6-year-olds and a left-side preference for counting objects and naming pictures by 6 years of age. Children were consistent in their special preferences when comparing object counting and picture naming, but not in other task pairings. Finally, spatial preferences were not related to cardinality comprehension. These results, together with other recent work, suggest a gradual development of spatial-numerical associations from early non-directional mappings into culturally constrained directional mappings.
The use of noise equivalent count rate and the NEMA phantom for PET image quality evaluation.
Yang, Xin; Peng, Hao
2015-03-01
PET image quality is directly associated with two important parameters among others: count-rate performance and image signal-to-noise ratio (SNR). The framework of noise equivalent count rate (NECR) was developed back in the 1990s and has been widely used since then to evaluate count-rate performance for PET systems. The concept of NECR is not entirely straightforward, however, and among the issues requiring clarification are its original definition, its relationship to image quality, and its consistency among different derivation methods. In particular, we try to answer whether a higher NECR measurement using a standard NEMA phantom actually corresponds to better imaging performance. The paper includes the following topics: 1) revisiting the original analytical model for NECR derivation; 2) validating three methods for NECR calculation based on the NEMA phantom/standard; and 3) studying the spatial dependence of NECR and quantitative relationship between NECR and image SNR. Copyright © 2015 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Susrama, I. G.; Purnama, K. E.; Purnomo, M. H.
2016-01-01
Oligospermia is a male fertility issue defined as a low sperm concentration in the ejaculate. Normally the sperm concentration is 20-120 million/ml, while Oligospermia patients has sperm concentration less than 20 million/ml. Sperm test done in the fertility laboratory to determine oligospermia by checking fresh sperm according to WHO standards in 2010 [9]. The sperm seen in a microscope using a Neubauer improved counting chamber and manually count the number of sperm. In order to be counted automatically, this research made an automation system to analyse and count the sperm concentration called Automated Analysis of Sperm Concentration Counters (A2SC2) using Otsu threshold segmentation process and morphology. Data sperm used is the fresh sperm directly in the analysis in the laboratory from 10 people. The test results using A2SC2 method obtained an accuracy of 91%. Thus in this study, A2SC2 can be used to calculate the amount and concentration of sperm automatically
MEASUREMENTS OF AIRBORNE CONCENTRATIONS OF RADON AND THORON DECAY PRODUCTS.
Chalupnik, S; Skubacz, K; Urban, P; Wysocka, M
2017-11-01
Liquid scintillation counting (LSC) is a measuring technique, broadly applied in environmental monitoring of radionuclides. One of the possible applications of LSC is the measurement of radon and thoron decay products. But this method is suitable only for grab sampling. For long-term measurements a different technique can be applied-monitors of potential alpha energy concentration (PAEC) with thermoluminescent detectors (TLD). In these devices, called Alfa-2000 sampling probe, TL detectors (CaSO4:Dy) are applied for alpha particles counting. Three independent heads are placed over the membrane filter in a dust sampler's microcyclone. Such solution enables simultaneous measurements of PAEC and dust content. Moreover, the information which is stored in TLD chips is the energy of alpha particles, not the number of counted particles. Therefore, the readout of TL detector shows directly potential alpha energy, with no dependence on equilibrium factor, etc. This technique, which had been used only for radon decay products measurements, was modified by author to allow simultaneous measurements of radon and thoron PAEC. The LSC method can be used for calibration of portable radon decay products monitors. The LSC method has the advantage to be an absolute one, the TLD method to measure directly the (dose relevant) deposited energy. © The Author 2017. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.
Marginalized zero-inflated Poisson models with missing covariates.
Benecha, Habtamu K; Preisser, John S; Divaris, Kimon; Herring, Amy H; Das, Kalyan
2018-05-11
Unlike zero-inflated Poisson regression, marginalized zero-inflated Poisson (MZIP) models for counts with excess zeros provide estimates with direct interpretations for the overall effects of covariates on the marginal mean. In the presence of missing covariates, MZIP and many other count data models are ordinarily fitted using complete case analysis methods due to lack of appropriate statistical methods and software. This article presents an estimation method for MZIP models with missing covariates. The method, which is applicable to other missing data problems, is illustrated and compared with complete case analysis by using simulations and dental data on the caries preventive effects of a school-based fluoride mouthrinse program. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
ERIC Educational Resources Information Center
Gipps, John
1995-01-01
Presents an activity to determine whether the radioactivity of a pure potassium salt is directly proportional to the amount of potassium in it and whether this could be used as a method of analysis for potassium in a solid. (MKR)
Means and method for calibrating a photon detector utilizing electron-photon coincidence
NASA Technical Reports Server (NTRS)
Srivastava, S. K. (Inventor)
1984-01-01
An arrangement for calibrating a photon detector particularly applicable for the ultraviolet and vacuum ultraviolet regions is based on electron photon coincidence utilizing crossed electron beam atom beam collisions. Atoms are excited by electrons which lose a known amount of energy and scatter with a known remaining energy, while the excited atoms emit photons of known radiation. Electrons of the known remaining energy are separated from other electrons and are counted. Photons emitted in a direction related to the particular direction of scattered electrons are detected to serve as a standard. Each of the electrons is used to initiate the measurements of a time interval which terminates with the arrival of a photon exciting the photon detector. Only the number of time intervals related to the coincidence correlation and of electrons scattered in the particular direction with the known remaining energy and photons of a particular radiation level emitted due to the collisions of such scattered electrons are counted. The detector calibration is related to the number of counted electrons and photons.
Menlove, Howard O.; Stewart, James E.
1986-01-01
Apparatus and method for the direct, nondestructive evaluation of the .sup.235 U nuclide content of samples containing UF.sub.6, UF.sub.4, or UO.sub.2 utilizing the passive neutron self-interrogation of the sample resulting from the intrinsic production of neutrons therein. The ratio of the emitted neutron coincidence count rate to the total emitted neutron count rate is determined and yields a measure of the bulk fissile mass. The accuracy of the method is 6.8% (1.sigma.) for cylinders containing UF.sub.6 with enrichments ranging from 6% to 98% with measurement times varying from 3-6 min. The samples contained from below 1 kg to greater than 16 kg. Since the subject invention relies on fast neutron self-interrogation, complete sampling of the UF.sub.6 takes place, reducing difficulties arising from inhomogeneity of the sample which adversely affects other assay procedures.
Menlove, H.O.; Stewart, J.E.
1985-02-04
Apparatus and method for the direct, nondestructive evaluation of the /sup 235/U nuclide content of samples containing UF/sub 6/, UF/sub 4/, or UO/sub 2/ utilizing the passive neutron self-interrogation of the sample resulting from the intrinsic production of neutrons therein. The ratio of the emitted neutron coincidence count rate to the total emitted neutron count rate is determined and yields a measure of the bulk fissile mass. The accuracy of the method is 6.8% (1sigma) for cylinders containing UF/sub 6/ with enrichments ranging from 6% to 98% with measurement times varying from 3-6 min. The samples contained from below 1 kg to greater than 16 kg. Since the subject invention relies on fast neutron self-interrogation, complete sampling of the UF/sub 6/ takes place, reducing difficulties arising from inhomogeneity of the sample which adversely affects other assay procedures. 4 figs., 1 tab.
The efficacy of ultrasound treatment as a reversible male contraceptive in the rhesus monkey.
VandeVoort, Catherine A; Tollner, Theodore L
2012-09-12
The use of therapeutic ultrasound as a contraceptive approach has involved nonhuman primates as well as rats and dogs. The current study was undertaken to determine whether this treatment could be a method for reversible contraception, using a model with testes size similar to adult humans. Two methods of ultrasound exposure were used, either the transducer probe at the bottom of a cup filled with saline (Cup) or direct application to the surface of the scrotum (Direct). Four adult rhesus (Macaca mulatta) males with normal semen parameters were treated with therapeutic ultrasound at 2.5 W/cm(2) for 30 min. Treatment was given 3 times, one every other day on a Monday-Wednesday-Friday schedule. For each male, semen quality was evaluated a minimum of three times over several months prior to ultrasound exposure and weekly for two months following ultrasound treatment. Semen samples from all males, regardless of exposure method, exhibited a decrease in the percentage of motile sperm following ultrasound treatment. There was an average reduction in motility of 40% the week following treatment. Similarly, curvilinear velocity and the percentage of sperm with a normally shaped flagellum were also reduced in all males following ultrasound treatment. A significant reduction in the total number of sperm in an ejaculate (total sperm count) was only observed in males that received ultrasound via the cup method. Following treatment via the cup method, males exhibited up to a 91.7% decrease in average total sperm count (n = 2). Sperm count did not approach pre-treatment levels until 8 weeks following ultrasound exposure. The sustained reduction in sperm count, percent motility, normal morphology, and sperm vigor with the cup exposure method provides proof of principle that testicular treatment with ultrasound can be an effective contraceptive approach in humans.
High-speed optical switch fabrics with large port count.
Yeo, Yong-Kee; Xu, Zhaowen; Wang, Dawei; Liu, Jianguo; Wang, Yixin; Cheng, Tee-Hiang
2009-06-22
We report a novel architecture that can be used to construct optical switch fabrics with very high port count and nanoseconds switching speed. It is well known that optical switch fabrics with very fast switching time and high port count are challenging to realize. Currently, one of the most promising solutions is based on a combination of wavelength-tunable lasers and the arrayed waveguide grating router (AWGR). To scale up the number of ports in such switches, a direct method is to use AWGRs with a high channel count. However, such AWGRs introduce very large crosstalk noise due to the close wavelength channel spacing. In this paper, we propose an architecture for realizing a high-port count optical switch fabric using a combination of low-port count AWGRs, optical ON-OFF gates and WDM couplers. Using this new methodology, we constructed a proof-of concept experiment to demonstrate the feasibility of a 256 x 256 optical switch fabric. To our knowledge, this port count is the highest ever reported for switch fabrics of this type.
A removal model for estimating detection probabilities from point-count surveys
Farnsworth, G.L.; Pollock, K.H.; Nichols, J.D.; Simons, T.R.; Hines, J.E.; Sauer, J.R.
2002-01-01
Use of point-count surveys is a popular method for collecting data on abundance and distribution of birds. However, analyses of such data often ignore potential differences in detection probability. We adapted a removal model to directly estimate detection probability during point-count surveys. The model assumes that singing frequency is a major factor influencing probability of detection when birds are surveyed using point counts. This may be appropriate for surveys in which most detections are by sound. The model requires counts to be divided into several time intervals. Point counts are often conducted for 10 min, where the number of birds recorded is divided into those first observed in the first 3 min, the subsequent 2 min, and the last 5 min. We developed a maximum-likelihood estimator for the detectability of birds recorded during counts divided into those intervals. This technique can easily be adapted to point counts divided into intervals of any length. We applied this method to unlimited-radius counts conducted in Great Smoky Mountains National Park. We used model selection criteria to identify whether detection probabilities varied among species, throughout the morning, throughout the season, and among different observers. We found differences in detection probability among species. Species that sing frequently such as Winter Wren (Troglodytes troglodytes) and Acadian Flycatcher (Empidonax virescens) had high detection probabilities (∼90%) and species that call infrequently such as Pileated Woodpecker (Dryocopus pileatus) had low detection probability (36%). We also found detection probabilities varied with the time of day for some species (e.g. thrushes) and between observers for other species. We used the same approach to estimate detection probability and density for a subset of the observations with limited-radius point counts.
Direct Determination of Activities for Microorganisms of Chesapeake Bay Populations
Tabor, Paul S.; Neihof, Rex A.
1984-01-01
We used three methods in determination of the metabolically active individual microorganisms for Chesapeake Bay surface and near-bottom populations over a period of a year. Synthetically active bacteria were recognized as enlarged cells in samples amended with nalidixic acid and yeast extract and incubated for 6 h. Microorganisms with active electron transport systems were identified by the reduction of a tetrazolium salt electron acceptor. Microorganisms active in uptake of amino acids, thymidine, and acetate were determined by microautoradiography. In conjunction with enumeration of active organisms, a total direct count was made for each sample preparation by epifluorescence microscopy. For the majority of samples, numbers of amino acid uptake-active organisms were greater than numbers of organisms determined to be active by other direct measurements. Within a sample, the numbers of uptake-active organisms (amino acids or thymidine) and electron transport system-active organisms were significantly different for 68% of the samples. Numbers of synthetically active bacteria were generally less than numbers determined by the other direct activity measurements. The distribution of total counts in the 11 samplings showed a seasonal pattern, with significant dependence on in situ water temperature, increasing from March to September and then decreasing through February. Synthetically active bacteria and amino acid uptake-active organisms showed a significant dependence on in situ temperature, independent of the function of temperature on total counts. Numbers of active organisms determined by at least one of the methods used exceeded 25% of the total population of all samplings, and from June through September, >85% of the total population was found to be active by at least one direct activity measurement. Thus, active rather than dormant organisms compose a major portion of the microbial population in this region of Chesapeake Bay. PMID:16346659
Direct determination of activities for microorganisms of chesapeake bay populations.
Tabor, P S; Neihof, R A
1984-11-01
We used three methods in determination of the metabolically active individual microorganisms for Chesapeake Bay surface and near-bottom populations over a period of a year. Synthetically active bacteria were recognized as enlarged cells in samples amended with nalidixic acid and yeast extract and incubated for 6 h. Microorganisms with active electron transport systems were identified by the reduction of a tetrazolium salt electron acceptor. Microorganisms active in uptake of amino acids, thymidine, and acetate were determined by microautoradiography. In conjunction with enumeration of active organisms, a total direct count was made for each sample preparation by epifluorescence microscopy. For the majority of samples, numbers of amino acid uptake-active organisms were greater than numbers of organisms determined to be active by other direct measurements. Within a sample, the numbers of uptake-active organisms (amino acids or thymidine) and electron transport system-active organisms were significantly different for 68% of the samples. Numbers of synthetically active bacteria were generally less than numbers determined by the other direct activity measurements. The distribution of total counts in the 11 samplings showed a seasonal pattern, with significant dependence on in situ water temperature, increasing from March to September and then decreasing through February. Synthetically active bacteria and amino acid uptake-active organisms showed a significant dependence on in situ temperature, independent of the function of temperature on total counts. Numbers of active organisms determined by at least one of the methods used exceeded 25% of the total population of all samplings, and from June through September, >85% of the total population was found to be active by at least one direct activity measurement. Thus, active rather than dormant organisms compose a major portion of the microbial population in this region of Chesapeake Bay.
Temporal Association Between Nonfatal Self-Directed Violence and Tree and Grass Pollen Counts.
Jeon-Slaughter, Haekyung; Claassen, Cynthia A; Khan, David A; Mihalakos, Perry; Lee, Kevin B; Brown, E Sherwood
2016-09-01
Prior research suggests a possible association between pollen and suicide. No studies have examined the relationship between pollen and attempted suicide. This study examines the temporal association between airborne pollen counts and nonfatal suicidal and nonsuicidal self-directed violence (SDV) requiring an emergency department visit. Data on daily emergency department visits due to nonfatal SDV as identified by ICD-9 diagnosis criteria were extracted from emergency department medical records of Parkland Memorial Hospital in Dallas, Texas, between January 2000 and December 2003. Concurrent daily airborne tree, grass, and ragweed pollen data from the city of Dallas were extracted from the National Allergy Bureau online database. The data were analyzed using the time series method of generalized autoregressive conditional heteroskedasticity. There were statistically significant and positive temporal associations between tree pollen counts and the number of nonfatal SDV events among women (P = .04) and between grass pollen counts and number of nonfatal SDV events among both men (P = .03) and women (P < .0001). There was no significant temporal association found between ragweed pollen counts and number of nonfatal SDV events. The study findings suggest that an increase in nonfatal SDV is associated with changes in tree and grass pollen counts. This is the first study that has examined an association between seasonal variation in tree and grass pollen levels and nonfatal SDV event data. The study also used a narrowly defined geographic area and temporal window. The findings suggest that pollen count may be a factor influencing seasonal patterns in suicidal behavior. © Copyright 2016 Physicians Postgraduate Press, Inc.
Pulse pileup statistics for energy discriminating photon counting x-ray detectors
DOE Office of Scientific and Technical Information (OSTI.GOV)
Wang, Adam S.; Harrison, Daniel; Lobastov, Vladimir
Purpose: Energy discriminating photon counting x-ray detectors can be subject to a wide range of flux rates if applied in clinical settings. Even when the incident rate is a small fraction of the detector's maximum periodic rate N{sub 0}, pulse pileup leads to count rate losses and spectral distortion. Although the deterministic effects can be corrected, the detrimental effect of pileup on image noise is not well understood and may limit the performance of photon counting systems. Therefore, the authors devise a method to determine the detector count statistics and imaging performance. Methods: The detector count statistics are derived analyticallymore » for an idealized pileup model with delta pulses of a nonparalyzable detector. These statistics are then used to compute the performance (e.g., contrast-to-noise ratio) for both single material and material decomposition contrast detection tasks via the Cramer-Rao lower bound (CRLB) as a function of the detector input count rate. With more realistic unipolar and bipolar pulse pileup models of a nonparalyzable detector, the imaging task performance is determined by Monte Carlo simulations and also approximated by a multinomial method based solely on the mean detected output spectrum. Photon counting performance at different count rates is compared with ideal energy integration, which is unaffected by count rate. Results: The authors found that an ideal photon counting detector with perfect energy resolution outperforms energy integration for our contrast detection tasks, but when the input count rate exceeds 20%N{sub 0}, many of these benefits disappear. The benefit with iodine contrast falls rapidly with increased count rate while water contrast is not as sensitive to count rates. The performance with a delta pulse model is overoptimistic when compared to the more realistic bipolar pulse model. The multinomial approximation predicts imaging performance very close to the prediction from Monte Carlo simulations. The monoenergetic image with maximum contrast-to-noise ratio from dual energy imaging with ideal photon counting is only slightly better than with dual kVp energy integration, and with a bipolar pulse model, energy integration outperforms photon counting for this particular metric because of the count rate losses. However, the material resolving capability of photon counting can be superior to energy integration with dual kVp even in the presence of pileup because of the energy information available to photon counting. Conclusions: A computationally efficient multinomial approximation of the count statistics that is based on the mean output spectrum can accurately predict imaging performance. This enables photon counting system designers to directly relate the effect of pileup to its impact on imaging statistics and how to best take advantage of the benefits of energy discriminating photon counting detectors, such as material separation with spectral imaging.« less
Mavridou, A; Smeti, E; Mandilara, G; Mandilara, G; Boufa, P; Vagiona-Arvanitidou, M; Vantarakis, A; Vassilandonopoulou, G; Pappa, O; Roussia, V; Tzouanopoulos, A; Livadara, M; Aisopou, I; Maraka, V; Nikolaou, E; Mandilara, G
2010-01-01
In this study ten laboratories in Greece compared the performance of reference method TTC Tergitol 7 Agar (with the additional test of beta-glucuronidase production) with five alternative methods, to detect E. coli in water, in line with European Water Directive recommendations. The samples were prepared by spiking drinking water with sewage effluent following a standard protocol. Chlorinated and non-chlorinated samples were used. The statistical analysis was based on the mean relative difference of confirmed counts and was performed in line with ISO 17994. The results showed that in total, three of the alternative methods (Chromocult Coliform agar, Membrane Lauryl Sulfate agar and Trypton Bilex-glucuronidase medium) were not different from TTC Tergitol 7 agar (TTC Tergitol 7 agar vs Chromocult Coliform agar, 294 samples, mean RD% 5.55; vs MLSA, 302 samples, mean RD% 1; vs TBX, 297 samples, mean RD% -2.78). The other two alternative methods (Membrane Faecal coliform medium and Colilert 18/ Quantitray) gave significantly higher counts than TTC Tergitol 7 agar (TTC Tergitol 7 agar vs MFc, 303 samples, mean RD% 8.81; vs Colilert-18/Quantitray, 76 samples, mean RD% 18.91). In other words, the alternative methods generated performance that was as reliable as, or even better than, the reference method. This study will help laboratories in Greece overcome culture and counting problems deriving from the EU reference method for E. coli counts in water samples.
Development of a nematode offspring counting assay for rapid and simple soil toxicity assessment.
Kim, Shin Woong; Moon, Jongmin; Jeong, Seung-Woo; An, Youn-Joo
2018-05-01
Since the introduction of standardized nematode toxicity assays by the American Society for Testing and Materials (ASTM) and International Organization for Standardization (ISO), many studies have reported their use. Given that the currently used standardized nematode toxicity assays have certain limitations, in this study, we examined the use of a novel nematode offspring counting assay for evaluating soil ecotoxicity based on a previous soil-agar isolation method used to recover live adult nematodes. In this new assay, adult Caenorhabditis elegans were exposed to soil using a standardized toxicity assay procedure, and the resulting offspring in test soils attracted by a microbial food source in agar plates were counted. This method differs from previously used assays in terms of its endpoint, namely, the number of nematode offspring. The applicability of the bioassay was demonstrated using metal-spiked soils, which revealed metal concentration-dependent responses, and with 36 field soil samples characterized by different physicochemical properties and containing various metals. Principal component analysis revealed that texture fraction (clay, sand, and silt) and electrical conductivity values were the main factors influencing the nematode offspring counting assay, and these findings warrant further investigation. The nematode offspring counting assay is a rapid and simple process that can provide multi-directional toxicity assessment when used in conjunction with other standard methods. Copyright © 2018 Elsevier Ltd. All rights reserved.
Evaluation of Pulse Counting for the Mars Organic Mass Analyzer (MOMA) Ion Trap Detection Scheme
NASA Technical Reports Server (NTRS)
Van Amerom, Friso H.; Short, Tim; Brinckerhoff, William; Mahaffy, Paul; Kleyner, Igor; Cotter, Robert J.; Pinnick, Veronica; Hoffman, Lars; Danell, Ryan M.; Lyness, Eric I.
2011-01-01
The Mars Organic Mass Analyzer is being developed at Goddard Space Flight Center to identify organics and possible biological compounds on Mars. In the process of characterizing mass spectrometer size, weight, and power consumption, the use of pulse counting was considered for ion detection. Pulse counting has advantages over analog-mode amplification of the electron multiplier signal. Some advantages are reduced size of electronic components, low power consumption, ability to remotely characterize detector performance, and avoidance of analog circuit noise. The use of pulse counting as a detection method with ion trap instruments is relatively rare. However, with the recent development of high performance electrical components, this detection method is quite suitable and can demonstrate significant advantages over analog methods. Methods A prototype quadrupole ion trap mass spectrometer with an internal electron ionization source was used as a test setup to develop and evaluate the pulse-counting method. The anode signal from the electron multiplier was preamplified. The an1plified signal was fed into a fast comparator for pulse-level discrimination. The output of the comparator was fed directly into a Xilinx FPGA development board. Verilog HDL software was written to bin the counts at user-selectable intervals. This system was able to count pulses at rates in the GHz range. The stored ion count nun1ber per bin was transferred to custom ion trap control software. Pulse-counting mass spectra were compared with mass spectra obtained using the standard analog-mode ion detection. Prelin1inary Data Preliminary mass spectra have been obtained for both analog mode and pulse-counting mode under several sets of instrument operating conditions. Comparison of the spectra revealed better peak shapes for pulse-counting mode. Noise levels are as good as, or better than, analog-mode detection noise levels. To artificially force ion pile-up conditions, the ion trap was overfilled and ions were ejected at very high scan rates. Pile-up of ions was not significant for the ion trap under investigation even though the ions are ejected in so-called 'ion-micro packets'. It was found that pulse counting mode had higher dynamic range than analog mode, and that the first amplification stage in analog mode can distort mass peaks. The inherent speed of the pulse counting method also proved to be beneficial to ion trap operation and ion ejection characterization. Very high scan rates were possible with pulse counting since the digital circuitry response time is so much smaller than with the analog method. Careful investigation of the pulse-counting data also allowed observation of the applied resonant ejection frequency during mass analysis. Ejection of ion micro packets could be clearly observed in the binned data. A second oscillation frequency, much lower than the secular frequency, was also observed. Such an effect was earlier attributed to the oscillation of the total plasma cloud in the ion trap. While the components used to implement pulse counting are quite advanced, due to their prevalence in consumer electronics, the cost of this detection system is no more than that of an analog mode system. Total pulse-counting detection system electronics cost is under $250
Method for spatially distributing a population
Bright, Edward A [Knoxville, TN; Bhaduri, Budhendra L [Knoxville, TN; Coleman, Phillip R [Knoxville, TN; Dobson, Jerome E [Lawrence, KS
2007-07-24
A process for spatially distributing a population count within a geographically defined area can include the steps of logically correlating land usages apparent from a geographically defined area to geospatial features in the geographically defined area and allocating portions of the population count to regions of the geographically defined area having the land usages, according to the logical correlation. The process can also include weighing the logical correlation for determining the allocation of portions of the population count and storing the allocated portions within a searchable data store. The logically correlating step can include the step of logically correlating time-based land usages to geospatial features of the geographically defined area. The process can also include obtaining a population count for the geographically defined area, organizing the geographically defined area into a plurality of sectors, and verifying the allocated portions according to direct observation.
Protecting count queries in study design
Sarwate, Anand D; Boxwala, Aziz A
2012-01-01
Objective Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. Methods A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Results Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Conclusions Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems. PMID:22511018
Veatch, Sarah L.; Machta, Benjamin B.; Shelby, Sarah A.; Chiang, Ethan N.; Holowka, David A.; Baird, Barbara A.
2012-01-01
We present an analytical method using correlation functions to quantify clustering in super-resolution fluorescence localization images and electron microscopy images of static surfaces in two dimensions. We use this method to quantify how over-counting of labeled molecules contributes to apparent self-clustering and to calculate the effective lateral resolution of an image. This treatment applies to distributions of proteins and lipids in cell membranes, where there is significant interest in using electron microscopy and super-resolution fluorescence localization techniques to probe membrane heterogeneity. When images are quantified using pair auto-correlation functions, the magnitude of apparent clustering arising from over-counting varies inversely with the surface density of labeled molecules and does not depend on the number of times an average molecule is counted. In contrast, we demonstrate that over-counting does not give rise to apparent co-clustering in double label experiments when pair cross-correlation functions are measured. We apply our analytical method to quantify the distribution of the IgE receptor (FcεRI) on the plasma membranes of chemically fixed RBL-2H3 mast cells from images acquired using stochastic optical reconstruction microscopy (STORM/dSTORM) and scanning electron microscopy (SEM). We find that apparent clustering of FcεRI-bound IgE is dominated by over-counting labels on individual complexes when IgE is directly conjugated to organic fluorophores. We verify this observation by measuring pair cross-correlation functions between two distinguishably labeled pools of IgE-FcεRI on the cell surface using both imaging methods. After correcting for over-counting, we observe weak but significant self-clustering of IgE-FcεRI in fluorescence localization measurements, and no residual self-clustering as detected with SEM. We also apply this method to quantify IgE-FcεRI redistribution after deliberate clustering by crosslinking with two distinct trivalent ligands of defined architectures, and we evaluate contributions from both over-counting of labels and redistribution of proteins. PMID:22384026
Aslund, Magnus; Cederström, Björn; Lundqvist, Mats; Danielsson, Mats
2007-06-01
The physical performance of a scanning multislit full field digital mammography system was determined using basic image quality parameters. The system employs a direct detection detector comprised of linear silicon strip sensors in an edge-on geometry connected to photon counting electronics. The pixel size is 50 microm and the field of view 24 x 26 cm2. The performance was quantified using the presampled modulation transfer function, the normalized noise power spectrum and the detective quantum efficiency (DQE). Compared to conventional DQE methods, the scanning geometry with its intrinsic scatter rejection poses additional requirements on the measurement setup, which are investigated in this work. The DQE of the photon counting system was found to be independent of the dose level to the detector in the 7.6-206 microGy range. The peak DQE was 72% and 73% in the scan and slit direction, respectively, measured with a 28 kV W-0.5 mm Al anode-filter combination with an added 2 mm Al filtration.
An Embodiment Perspective on Number-Space Mapping in 3.5-Year-Old Dutch Children.
van 't Noordende, Jaccoline E; Volman, M Chiel J M; Leseman, Paul P M; Kroesbergen, Evelyn H
2017-01-01
Previous research suggests that block adding, subtracting and counting direction are early forms of number-space mapping. In this study, an embodiment perspective on these skills was taken. Embodiment theory assumes that cognition emerges through sensory-motor interaction with the environment. In line with this assumption, it was investigated if counting and adding/subtracting direction in young children is related to the hand they use during task performance. Forty-eight 3.5-year-old children completed a block adding, subtracting and counting task. They had to add and remove a block from a row of three blocks and count a row of five blocks. Adding, subtracting and counting direction were related to the hand the children used for task performance. Most children who used their right hand added, removed and started counting the blocks at the right side of the row. Most children who used their left hand added, removed and started counting the blocks at the left side of the row. It can be concluded that number-space mapping, as measured by direction of adding, subtracting and counting blocks, in young children is embodied: It is not fixed, but is related to the situation. © 2016 The Authors Infant and Child Development Published by John Wiley & Sons, Ltd.
Fission meter and neutron detection using poisson distribution comparison
Rowland, Mark S; Snyderman, Neal J
2014-11-18
A neutron detector system and method for discriminating fissile material from non-fissile material wherein a digital data acquisition unit collects data at high rate, and in real-time processes large volumes of data directly into information that a first responder can use to discriminate materials. The system comprises counting neutrons from the unknown source and detecting excess grouped neutrons to identify fission in the unknown source. Comparison of the observed neutron count distribution with a Poisson distribution is performed to distinguish fissile material from non-fissile material.
NASA Astrophysics Data System (ADS)
Khwarahm, Nabaz; Dash, Jadunandan; Atkinson, Peter M.; Newnham, R. M.; Skjøth, C. A.; Adams-Groom, B.; Caulton, Eric; Head, K.
2014-05-01
Constructing accurate predictive models for grass and birch pollen in the air, the two most important aeroallergens, for areas with variable climate conditions such as the United Kingdom, require better understanding of the relationships between pollen count in the air and meteorological variables. Variations in daily birch and grass pollen counts and their relationship with daily meteorological variables were investigated for nine pollen monitoring sites for the period 2000-2010 in the United Kingdom. An active pollen count sampling method was employed at each of the monitoring stations to sample pollen from the atmosphere. The mechanism of this method is based on the volumetric spore traps of Hirst design (Hirst in Ann Appl Biol 39(2):257-265,
High-Throughput Quantification of Bacterial-Cell Interactions Using Virtual Colony Counts
Hoffmann, Stefanie; Walter, Steffi; Blume, Anne-Kathrin; Fuchs, Stephan; Schmidt, Christiane; Scholz, Annemarie; Gerlach, Roman G.
2018-01-01
The quantification of bacteria in cell culture infection models is of paramount importance for the characterization of host-pathogen interactions and pathogenicity factors involved. The standard to enumerate bacteria in these assays is plating of a dilution series on solid agar and counting of the resulting colony forming units (CFU). In contrast, the virtual colony count (VCC) method is a high-throughput compatible alternative with minimized manual input. Based on the recording of quantitative growth kinetics, VCC relates the time to reach a given absorbance threshold to the initial cell count using a series of calibration curves. Here, we adapted the VCC method using the model organism Salmonella enterica sv. Typhimurium (S. Typhimurium) in combination with established cell culture-based infection models. For HeLa infections, a direct side-by-side comparison showed a good correlation of VCC with CFU counting after plating. For MDCK cells and RAW macrophages we found that VCC reproduced the expected phenotypes of different S. Typhimurium mutants. Furthermore, we demonstrated the use of VCC to test the inhibition of Salmonella invasion by the probiotic E. coli strain Nissle 1917. Taken together, VCC provides a flexible, label-free, automation-compatible methodology to quantify bacteria in in vitro infection assays. PMID:29497603
Bayesian approach for counting experiment statistics applied to a neutrino point source analysis
NASA Astrophysics Data System (ADS)
Bose, D.; Brayeur, L.; Casier, M.; de Vries, K. D.; Golup, G.; van Eijndhoven, N.
2013-12-01
In this paper we present a model independent analysis method following Bayesian statistics to analyse data from a generic counting experiment and apply it to the search for neutrinos from point sources. We discuss a test statistic defined following a Bayesian framework that will be used in the search for a signal. In case no signal is found, we derive an upper limit without the introduction of approximations. The Bayesian approach allows us to obtain the full probability density function for both the background and the signal rate. As such, we have direct access to any signal upper limit. The upper limit derivation directly compares with a frequentist approach and is robust in the case of low-counting observations. Furthermore, it allows also to account for previous upper limits obtained by other analyses via the concept of prior information without the need of the ad hoc application of trial factors. To investigate the validity of the presented Bayesian approach, we have applied this method to the public IceCube 40-string configuration data for 10 nearby blazars and we have obtained a flux upper limit, which is in agreement with the upper limits determined via a frequentist approach. Furthermore, the upper limit obtained compares well with the previously published result of IceCube, using the same data set.
Roteta, Miguel; Peyres, Virginia; Rodríguez Barquero, Leonor; García-Toraño, Eduardo; Arenillas, Pablo; Balpardo, Christian; Rodrígues, Darío; Llovera, Roberto
2012-09-01
The radionuclide (68)Ga is one of the few positron emitters that can be prepared in-house without the use of a cyclotron. It disintegrates to the ground state of (68)Zn partially by positron emission (89.1%) with a maximum energy of 1899.1 keV, and partially by electron capture (10.9%). This nuclide has been standardized in the frame of a cooperation project between the Radionuclide Metrology laboratories from CIEMAT (Spain) and CNEA (Argentina). Measurements involved several techniques: 4πβ-γ coincidences, integral gamma counting and Liquid Scintillation Counting using the triple to double coincidence ratio and the CIEMAT/NIST methods. Given the short half-life of the radionuclide assayed, a direct comparison between results from both laboratories was excluded and a comparison of experimental efficiencies of similar NaI detectors was used instead. Copyright © 2012 Elsevier Ltd. All rights reserved.
Incorporating availability for detection in estimates of bird abundance
Diefenbach, D.R.; Marshall, M.R.; Mattice, J.A.; Brauning, D.W.
2007-01-01
Several bird-survey methods have been proposed that provide an estimated detection probability so that bird-count statistics can be used to estimate bird abundance. However, some of these estimators adjust counts of birds observed by the probability that a bird is detected and assume that all birds are available to be detected at the time of the survey. We marked male Henslow's Sparrows (Ammodramus henslowii) and Grasshopper Sparrows (A. savannarum) and monitored their behavior during May-July 2002 and 2003 to estimate the proportion of time they were available for detection. We found that the availability of Henslow's Sparrows declined in late June to <10% for 5- or 10-min point counts when a male had to sing and be visible to the observer; but during 20 May-19 June, males were available for detection 39.1% (SD = 27.3) of the time for 5-min point counts and 43.9% (SD = 28.9) of the time for 10-min point counts (n = 54). We detected no temporal changes in availability for Grasshopper Sparrows, but estimated availability to be much lower for 5-min point counts (10.3%, SD = 12.2) than for 10-min point counts (19.2%, SD = 22.3) when males had to be visible and sing during the sampling period (n = 80). For distance sampling, we estimated the availability of Henslow's Sparrows to be 44.2% (SD = 29.0) and the availability of Grasshopper Sparrows to be 20.6% (SD = 23.5). We show how our estimates of availability can be incorporated in the abundance and variance estimators for distance sampling and modify the abundance and variance estimators for the double-observer method. Methods that directly estimate availability from bird counts but also incorporate detection probabilities need further development and will be important for obtaining unbiased estimates of abundance for these species.
Impedance technology reduces the enumeration time of Brettanomyces yeast during beer fermentation.
van Wyk, Sanelle; Silva, Filipa V M
2016-12-01
Brettanomyces yeasts are increasingly being used to produce lambic style beers and craft beers with unique flavors. Currently, the industry monitors Brettanomyces bruxellensis using time consuming plate counting. B. bruxellensis is a fastidious slow growing organism, requiring five days of incubation at 30°C for visible growth on agar plates. Thus, a need exists to develop a quicker, feasible method to enumerate this yeast. The aim of this study was therefore to determine the feasibility of using the 'direct' and 'indirect' impedance methods for the enumeration of B. bruxellensis in beer and to monitor the growth of the yeast during fermentation. The impedance methods were able to decrease the incubation time of beer samples containing Brettanomyces from 120 h down to 2 and 84 h for samples containing 10 7 and 10 3 cfu/mL, respectively. The 'indirect' method was more successful than the 'direct' method, presenting a smaller error and wider detection range. Overall, the 'indirect' impedance method is a viable alternative to plate counting for the enumeration of yeasts in the brewing industry because it decreases preparation and incubation times, thereby increasing throughput and decreasing the chance of contamination. Copyright © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.
Motif-Synchronization: A new method for analysis of dynamic brain networks with EEG
NASA Astrophysics Data System (ADS)
Rosário, R. S.; Cardoso, P. T.; Muñoz, M. A.; Montoya, P.; Miranda, J. G. V.
2015-12-01
The major aim of this work was to propose a new association method known as Motif-Synchronization. This method was developed to provide information about the synchronization degree and direction between two nodes of a network by counting the number of occurrences of some patterns between any two time series. The second objective of this work was to present a new methodology for the analysis of dynamic brain networks, by combining the Time-Varying Graph (TVG) method with a directional association method. We further applied the new algorithms to a set of human electroencephalogram (EEG) signals to perform a dynamic analysis of the brain functional networks (BFN).
Gopal, Judy; Lee, Chia-Hsun; Wu, Hui-Fen
2012-06-06
This study demonstrates the first use of matrix assisted laser desorption/ionization mass spectrometry (MALDI-MS) to trace the Invivo infection kinetics of the well known deadly pathogen Staphylococcus aureus in Swiss albino mice. The growth curve of the bacteria from the point of injection (200μL of bacterial suspension (10(8)cfu/mL)) into the mouse blood till mortality (death) was periodically analyzed using the plate counting method and MALDI-MS. Bacterial counts of 10(3)cfu/mL were observed in the log phase of the growth curve in the blood and 10(2)cfu/mL were observed in the urine samples. Death occurred in the log phase of the growth curve, where the bacterial counts showed steady increase. In other cases, the bacteria counts started decreasing after 48h and by 96h the bacteria got totally eliminated from the mouse and these mice survived. Direct MALDI-MS was not feasible for tracking the bacteria in the infected blood. However, ionic liquid 1-Butyl-3-methylimidazolium tetrafluoroborate was successful in enabling bacterial detection amidst the strong blood peaks. But, in the case of the urine analysis, it was observed that direct MALDI-MS was adequate to enable detection. The results obtained prove the efficacy of MALDI-MS for analyzing pathogenic bacteria in clinical samples. This article is part of a Special Issue entitled: Proteomics: The clinical link. Copyright © 2011 Elsevier B.V. All rights reserved.
Tacker, M; Hametner, C; Wepner, B
2002-01-01
Packaging materials are often considered a critical control point in HACCP systems of food companies. Methods for the determination of the microbial contamination rate of plastic cups, especially for dairy products, must reliably detect single moulds, yeasts or coliforms. In this study, a comparison of a specially adapted coating method, impedance method, direct inoculation and membrane filter technique was carried out to determine contamination with yeasts, moulds, coliforms and total bacterial counts using the appropriate agar in each case. The coating method is recommended for determining yeasts, moulds and coliforms as it allows the localization of the microorganisms as well as the determination of single microorganisms. For total bacterial count, a direct inoculation technique is proposed. The employing of simple measures in the production and during transport of packaging materials, such as dust-prevention or tight sealing in polyethylene bags, heavily reduces microbial contamination rates of packaging material. To reduce contamination rates further, electron beam irradiation was applied: plastic cups sealed in polyethylene bags were treated with 4-5 kGy, a dose that already leads to sterile polystyrene and polypropylene cups without influencing mechanical characteristics of the packaging material.
Differential white cell count by centrifugal microfluidics.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Sommer, Gregory Jon; Tentori, Augusto M.; Schaff, Ulrich Y.
We present a method for counting white blood cells that is uniquely compatible with centrifugation based microfluidics. Blood is deposited on top of one or more layers of density media within a microfluidic disk. Spinning the disk causes the cell populations within whole blood to settle through the media, reaching an equilibrium based on the density of each cell type. Separation and fluorescence measurement of cell types stained with a DNA dye is demonstrated using this technique. The integrated signal from bands of fluorescent microspheres is shown to be proportional to their initial concentration in suspension. Among the current generationmore » of medical diagnostics are devices based on the principle of centrifuging a CD sized disk functionalized with microfluidics. These portable 'lab on a disk' devices are capable of conducting multiple assays directly from a blood sample, embodied by platforms developed by Gyros, Samsung, and Abaxis. [1,2] However, no centrifugal platform to date includes a differential white blood cell count, which is an important metric complimentary to diagnostic assays. Measuring the differential white blood cell count (the relative fraction of granulocytes, lymphocytes, and monocytes) is a standard medical diagnostic technique useful for identifying sepsis, leukemia, AIDS, radiation exposure, and a host of other conditions that affect the immune system. Several methods exist for measuring the relative white blood cell count including flow cytometry, electrical impedance, and visual identification from a stained drop of blood under a microscope. However, none of these methods is easily incorporated into a centrifugal microfluidic diagnostic platform.« less
Death of the Escherichia coli K-12 strain W3110 in soil and water.
Bogosian, G; Sammons, L E; Morris, P J; O'Neil, J P; Heitkamp, M A; Weber, D B
1996-01-01
Whether Escherichia coli K-12 strain W3110 can enter the "viable but nonculturable" state was studied with sterile and nonsterile water and soil at various temperatures. In nonsterile river water, the plate counts of added E. coli cells dropped to less than 10 CFU/ml in less than 10 days. Acridine orange direct counts, direct viable counts, most-probable-number estimates, and PCR analyses indicated that the added E. coli cells were disappearing from the water in parallel with the number of CFU. Similar results were obtained with nonsterile soil, although the decline of the added E. coli was slower. In sterile water or soil, the added E. coli persisted for much longer, often without any decline in the plate counts even after 50 days. In sterile river water at 37 degrees C and sterile artificial seawater at 20 and 37 degrees C, the plate counts declined by 3 to 5 orders of magnitude, while the acridine orange direct counts remained unchanged. However, direct viable counts and various resuscitation studies all indicated that the nonculturable cells were nonviable. Thus, in either sterile or nonsterile water and soil, the decline in plate counts of E. coli K-12 strain W3110 is not due to the cells entering the viable but nonculturable state, but is simply due to their death. PMID:8900002
Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory
NASA Astrophysics Data System (ADS)
Aab, A.; Abreu, P.; Aglietta, M.; Ahn, E. J.; Samarai, I. Al; Albuquerque, I. F. M.; Allekotte, I.; Allison, P.; Almela, A.; Alvarez Castillo, J.; Alvarez-Muñiz, J.; Ambrosio, M.; Anastasi, G. A.; Anchordoqui, L.; Andrada, B.; Andringa, S.; Aramo, C.; Arqueros, F.; Arsene, N.; Asorey, H.; Assis, P.; Aublin, J.; Avila, G.; Badescu, A. M.; Balaceanu, A.; Baus, C.; Beatty, J. J.; Becker, K. H.; Bellido, J. A.; Berat, C.; Bertaina, M. E.; Bertou, X.; Biermann, P. L.; Billoir, P.; Biteau, J.; Blaess, S. G.; Blanco, A.; Blazek, J.; Bleve, C.; Boháčová, M.; Boncioli, D.; Bonifazi, C.; Borodai, N.; Botti, A. M.; Brack, J.; Brancus, I.; Bretz, T.; Bridgeman, A.; Briechle, F. L.; Buchholz, P.; Bueno, A.; Buitink, S.; Buscemi, M.; Caballero-Mora, K. S.; Caccianiga, B.; Caccianiga, L.; Cancio, A.; Canfora, F.; Caramete, L.; Caruso, R.; Castellina, A.; Cataldi, G.; Cazon, L.; Cester, R.; Chavez, A. G.; Chiavassa, A.; Chinellato, J. A.; Chudoba, J.; Clay, R. W.; Colalillo, R.; Coleman, A.; Collica, L.; Coluccia, M. R.; Conceição, R.; Contreras, F.; Cooper, M. J.; Coutu, S.; Covault, C. E.; Cronin, J.; Dallier, R.; D'Amico, S.; Daniel, B.; Dasso, S.; Daumiller, K.; Dawson, B. R.; de Almeida, R. M.; de Jong, S. J.; De Mauro, G.; de Mello Neto, J. R. T.; De Mitri, I.; de Oliveira, J.; de Souza, V.; Debatin, J.; del Peral, L.; Deligny, O.; Di Giulio, C.; Di Matteo, A.; Díaz Castro, M. L.; Diogo, F.; Dobrigkeit, C.; D'Olivo, J. C.; Dorofeev, A.; dos Anjos, R. C.; Dova, M. T.; Dundovic, A.; Ebr, J.; Engel, R.; Erdmann, M.; Erfani, M.; Escobar, C. O.; Espadanal, J.; Etchegoyen, A.; Falcke, H.; Fang, K.; Farrar, G.; Fauth, A. C.; Fazzini, N.; Fick, B.; Figueira, J. M.; Filevich, A.; Filipčič, A.; Fratu, O.; Freire, M. M.; Fujii, T.; Fuster, A.; García, B.; Garcia-Pinto, D.; Gaté, F.; Gemmeke, H.; Gherghel-Lascu, A.; Ghia, P. L.; Giaccari, U.; Giammarchi, M.; Giller, M.; Głas, D.; Glaser, C.; Glass, H.; Golup, G.; Gómez Berisso, M.; Gómez Vitale, P. F.; González, N.; Gookin, B.; Gordon, J.; Gorgi, A.; Gorham, P.; Gouffon, P.; Grillo, A. F.; Grubb, T. D.; Guarino, F.; Guedes, G. P.; Hampel, M. R.; Hansen, P.; Harari, D.; Harrison, T. A.; Harton, J. L.; Hasankiadeh, Q.; Haungs, A.; Hebbeker, T.; Heck, D.; Heimann, P.; Herve, A. E.; Hill, G. C.; Hojvat, C.; Holt, E.; Homola, P.; Hörandel, J. R.; Horvath, P.; Hrabovský, M.; Huege, T.; Hulsman, J.; Insolia, A.; Isar, P. G.; Jandt, I.; Jansen, S.; Johnsen, J. A.; Josebachuili, M.; Kääpä, A.; Kambeitz, O.; Kampert, K. H.; Kasper, P.; Katkov, I.; Keilhauer, B.; Kemp, E.; Kieckhafer, R. M.; Klages, H. O.; Kleifges, M.; Kleinfeller, J.; Krause, R.; Krohm, N.; Kuempel, D.; Kukec Mezek, G.; Kunka, N.; Kuotb Awad, A.; LaHurd, D.; Latronico, L.; Lauscher, M.; Lebrun, P.; Legumina, R.; Leigui de Oliveira, M. A.; Letessier-Selvon, A.; Lhenry-Yvon, I.; Link, K.; Lopes, L.; López, R.; López Casado, A.; Luce, Q.; Lucero, A.; Malacari, M.; Mallamaci, M.; Mandat, D.; Mantsch, P.; Mariazzi, A. G.; Mariş, I. C.; Marsella, G.; Martello, D.; Martinez, H.; Martínez Bravo, O.; Masías Meza, J. J.; Mathes, H. J.; Mathys, S.; Matthews, J.; Matthews, J. A. J.; Matthiae, G.; Mayotte, E.; Mazur, P. O.; Medina, C.; Medina-Tanco, G.; Melo, D.; Menshikov, A.; Messina, S.; Micheletti, M. I.; Middendorf, L.; Minaya, I. A.; Miramonti, L.; Mitrica, B.; Mockler, D.; Molina-Bueno, L.; Mollerach, S.; Montanet, F.; Morello, C.; Mostafá, M.; Müller, G.; Muller, M. A.; Müller, S.; Naranjo, I.; Navas, S.; Nellen, L.; Neuser, J.; Nguyen, P. H.; Niculescu-Oglinzanu, M.; Niechciol, M.; Niemietz, L.; Niggemann, T.; Nitz, D.; Nosek, D.; Novotny, V.; Nožka, H.; Núñez, L. A.; Ochilo, L.; Oikonomou, F.; Olinto, A.; Pakk Selmi-Dei, D.; Palatka, M.; Pallotta, J.; Papenbreer, P.; Parente, G.; Parra, A.; Paul, T.; Pech, M.; Pedreira, F.; Pȩkala, J.; Pelayo, R.; Peña-Rodriguez, J.; Pereira, L. A. S.; Perrone, L.; Peters, C.; Petrera, S.; Phuntsok, J.; Piegaia, R.; Pierog, T.; Pieroni, P.; Pimenta, M.; Pirronello, V.; Platino, M.; Plum, M.; Porowski, C.; Prado, R. R.; Privitera, P.; Prouza, M.; Quel, E. J.; Querchfeld, S.; Quinn, S.; Ramos-Pollant, R.; Rautenberg, J.; Ravignani, D.; Reinert, D.; Revenu, B.; Ridky, J.; Risse, M.; Ristori, P.; Rizi, V.; Rodrigues de Carvalho, W.; Rodriguez Fernandez, G.; Rodriguez Rojo, J.; Rodríguez-Frías, M. D.; Rogozin, D.; Rosado, J.; Roth, M.; Roulet, E.; Rovero, A. C.; Saffi, S. J.; Saftoiu, A.; Salazar, H.; Saleh, A.; Salesa Greus, F.; Salina, G.; Sanabria Gomez, J. D.; Sánchez, F.; Sanchez-Lucas, P.; Santos, E. M.; Santos, E.; Sarazin, F.; Sarkar, B.; Sarmento, R.; Sarmiento-Cano, C.; Sato, R.; Scarso, C.; Schauer, M.; Scherini, V.; Schieler, H.; Schmidt, D.; Scholten, O.; Schovánek, P.; Schröder, F. G.; Schulz, A.; Schulz, J.; Schumacher, J.; Sciutto, S. J.; Segreto, A.; Settimo, M.; Shadkam, A.; Shellard, R. C.; Sigl, G.; Silli, G.; Sima, O.; Śmiałkowski, A.; Šmída, R.; Snow, G. R.; Sommers, P.; Sonntag, S.; Sorokin, J.; Squartini, R.; Stanca, D.; Stanič, S.; Stasielak, J.; Strafella, F.; Suarez, F.; Suarez Durán, M.; Sudholz, T.; Suomijärvi, T.; Supanitsky, A. D.; Sutherland, M. S.; Swain, J.; Szadkowski, Z.; Taborda, O. A.; Tapia, A.; Tepe, A.; Theodoro, V. M.; Timmermans, C.; Todero Peixoto, C. J.; Tomankova, L.; Tomé, B.; Tonachini, A.; Torralba Elipe, G.; Torres Machado, D.; Torri, M.; Travnicek, P.; Trini, M.; Ulrich, R.; Unger, M.; Urban, M.; Valbuena-Delgado, A.; Valdés Galicia, J. F.; Valiño, I.; Valore, L.; van Aar, G.; van Bodegom, P.; van den Berg, A. M.; van Vliet, A.; Varela, E.; Vargas Cárdenas, B.; Varner, G.; Vázquez, J. R.; Vázquez, R. A.; Veberič, D.; Verzi, V.; Vicha, J.; Villaseñor, L.; Vorobiov, S.; Wahlberg, H.; Wainberg, O.; Walz, D.; Watson, A. A.; Weber, M.; Weindl, A.; Wiencke, L.; Wilczyński, H.; Winchen, T.; Wittkowski, D.; Wundheiler, B.; Wykes, S.; Yang, L.; Yelos, D.; Yushkov, A.; Zas, E.; Zavrtanik, D.; Zavrtanik, M.; Zepeda, A.; Zimmermann, B.; Ziolkowski, M.; Zong, Z.; Zuccarello, F.
2017-03-01
AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), is proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.
Villamor, N; Kirsch, A; Huhn, D; Vives-Corrons, J L; Serke, S
1996-06-01
Flow cytometrical methods have been introduced recently as an alternative to the enumeration of reticulocytes by microscopy. Two of these methods have gained widespread use in haematological practice; the multiparametric flow cytometer using thiazole orange staining (Retic-Count, FACScan) and the single-application reticulocyte counter using auramine-O staining (R-series, Sysmex). Several studies have emphasized the excellent correlations between microscopy and these techniques. The purpose of our study has been to examine the specificity of these automated devices with regard to cells classified as 'reticulocytes' and the effect that this may have on measures of reticulocyte maturity. Our results indicate that the specificity of reticulocyte measurements by both the Sysmex R-1000/-3000 and the Retic-Count system is relatively low. This is due to the presence of leucocytes amongst cells classified as reticulocytes. These leucocytes display intense staining with either dye, leading to an erroneous estimation of RMI (thiazole orange) and high fluorescence count (R-1000/-3000). This error is directly correlated with the leucocyte count. The basis for reticulocyte identification should be improved before automated estimation of reticulocyte maturation can be used in clinical practice.
Muon counting using silicon photomultipliers in the AMIGA detector of the Pierre Auger observatory
Aab, A.; Abreu, P.; Aglietta, M.; ...
2017-03-03
Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), ismore » proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.« less
On the decades-long stability of the interstellar wind through the solar system
NASA Astrophysics Data System (ADS)
Lallement, R.; Bertaux, J. L.
2014-05-01
We have revisited the series of observations recently used to infer a temporal variation in the interstellar helium flow over the past forty years. Concerning the recent IBEX-Lo direct detection of helium neutrals, there are two types of precise and unambiguous measurements that do not rely on the exact response of the instrument: the count rate maxima as a function of the spin angle, which determines the ecliptic latitude of the flow, and the count rate maxima as a function of IBEX longitude, which determines a tight relationship between the ecliptic longitude of the flow and its velocity far from the Sun. These measurements provide parameters (and couples of parameters in the second case) that are remarkably similar to the canonical, old values. In contrast, the preferred choice of a lower velocity and higher longitude reported before from IBEX data is only based on the count rate variation (at each spin phase maximum) as a function of the satellite longitude, when drifting across the region of high fluxes. We have examined the consequences of dead-time counting effects and conclude that including them at a realistic level is sufficient to reconcile the data with the old parameters, calling for further investigations. We discuss the analyses of the STEREO pickup ion data and argue that the statistical method that has been preferred to infer the neutral flow longitude (instead of the more direct method based on the pickup ion maximum flux directions) is not appropriate. Moreover, transport effects may have been significant at the very weak solar activity level of 2007-2009, in which case the longitudes of the pickup ion maxima are only upper limits on the flow longitude. Finally, we found that using some flow longitude determinations based on UV glow data is not adequate. Based on this global study, and at variance with recent conclusions, we find no evidence for a temporal variability of the interstellar helium flow. This has implications for inner and outer heliosphere studies.
Microbial Contamination of Chicken Wings: An Open-Ended Laboratory Project.
ERIC Educational Resources Information Center
Deutch, Charles E.
2001-01-01
Introduces the chicken wing project in which students assess the microbial contamination of chicken wings for the safety of foods. Uses the colony counting technique and direct wash fluid examination for determining the microbial contamination, and investigates methods to reduce the level of microbial contamination. (Contains 14 references.) (YDS)
USDA-ARS?s Scientific Manuscript database
The standard sampling technique used to quantify cotton fleahopper, Pseudatomoscelis seriatus (Reuter), abundance in cotton, Gossypium hirsutum L., involves direct counts of adults and nymphs on plants. This method, however, becomes increasingly laborious and time consuming as plants increase in si...
2013-01-01
Background Intraoperative detection of 18F-FDG-avid tissue sites during 18F-FDG-directed surgery can be very challenging when utilizing gamma detection probes that rely on a fixed target-to-background (T/B) ratio (ratiometric threshold) for determination of probe positivity. The purpose of our study was to evaluate the counting efficiency and the success rate of in situ intraoperative detection of 18F-FDG-avid tissue sites (using the three-sigma statistical threshold criteria method and the ratiometric threshold criteria method) for three different gamma detection probe systems. Methods Of 58 patients undergoing 18F-FDG-directed surgery for known or suspected malignancy using gamma detection probes, we identified nine 18F-FDG-avid tissue sites (from amongst seven patients) that were seen on same-day preoperative diagnostic PET/CT imaging, and for which each 18F-FDG-avid tissue site underwent attempted in situ intraoperative detection concurrently using three gamma detection probe systems (K-alpha probe, and two commercially-available PET-probe systems), and then were subsequently surgical excised. Results The mean relative probe counting efficiency ratio was 6.9 (± 4.4, range 2.2–15.4) for the K-alpha probe, as compared to 1.5 (± 0.3, range 1.0–2.1) and 1.0 (± 0, range 1.0–1.0), respectively, for two commercially-available PET-probe systems (P < 0.001). Successful in situ intraoperative detection of 18F-FDG-avid tissue sites was more frequently accomplished with each of the three gamma detection probes tested by using the three-sigma statistical threshold criteria method than by using the ratiometric threshold criteria method, specifically with the three-sigma statistical threshold criteria method being significantly better than the ratiometric threshold criteria method for determining probe positivity for the K-alpha probe (P = 0.05). Conclusions Our results suggest that the improved probe counting efficiency of the K-alpha probe design used in conjunction with the three-sigma statistical threshold criteria method can allow for improved detection of 18F-FDG-avid tissue sites when a low in situ T/B ratio is encountered. PMID:23496877
A generalised random encounter model for estimating animal density with remote sensor data.
Lucas, Tim C D; Moorcroft, Elizabeth A; Freeman, Robin; Rowcliffe, J Marcus; Jones, Kate E
2015-05-01
Wildlife monitoring technology is advancing rapidly and the use of remote sensors such as camera traps and acoustic detectors is becoming common in both the terrestrial and marine environments. Current methods to estimate abundance or density require individual recognition of animals or knowing the distance of the animal from the sensor, which is often difficult. A method without these requirements, the random encounter model (REM), has been successfully applied to estimate animal densities from count data generated from camera traps. However, count data from acoustic detectors do not fit the assumptions of the REM due to the directionality of animal signals.We developed a generalised REM (gREM), to estimate absolute animal density from count data from both camera traps and acoustic detectors. We derived the gREM for different combinations of sensor detection widths and animal signal widths (a measure of directionality). We tested the accuracy and precision of this model using simulations of different combinations of sensor detection widths and animal signal widths, number of captures and models of animal movement.We find that the gREM produces accurate estimates of absolute animal density for all combinations of sensor detection widths and animal signal widths. However, larger sensor detection and animal signal widths were found to be more precise. While the model is accurate for all capture efforts tested, the precision of the estimate increases with the number of captures. We found no effect of different animal movement models on the accuracy and precision of the gREM.We conclude that the gREM provides an effective method to estimate absolute animal densities from remote sensor count data over a range of sensor and animal signal widths. The gREM is applicable for count data obtained in both marine and terrestrial environments, visually or acoustically (e.g. big cats, sharks, birds, echolocating bats and cetaceans). As sensors such as camera traps and acoustic detectors become more ubiquitous, the gREM will be increasingly useful for monitoring unmarked animal populations across broad spatial, temporal and taxonomic scales.
Reyes, Mayra I; Pérez, Cynthia M; Negrón, Edna L
2008-03-01
Consumers increasingly use bottled water and home water treatment systems to avoid direct tap water. According to the International Bottled Water Association (IBWA), an industry trade group, 5 billion gallons of bottled water were consumed by North Americans in 2001. The principal aim of this study was to assess the microbial quality of in-house and imported bottled water for human consumption, by measurement and comparison of the concentration of bacterial endotoxin and standard cultivable methods of indicator microorganisms, specifically, heterotrophic and fecal coliform plate counts. A total of 21 brands of commercial bottled water, consisting of 10 imported and 11 in-house brands, selected at random from 96 brands that are consumed in Puerto Rico, were tested at three different time intervals. The Standard Limulus Amebocyte Lysate test, gel clot method, was used to measure the endotoxin concentrations. The minimum endotoxin concentration in 63 water samples was less than 0.0625 EU/mL, while the maximum was 32 EU/mL. The minimum bacterial count showed no growth, while the maximum was 7,500 CFU/mL. Bacterial isolates like P. fluorescens, Corynebacterium sp. J-K, S. paucimobilis, P. versicularis, A. baumannii, P. chlororaphis, F. indologenes, A. faecalis and P. cepacia were identified. Repeated measures analysis of variance demonstrated that endotoxin concentration did not change over time, while there was a statistically significant (p < 0.05) decrease in bacterial count over time. In addition, multiple linear regression analysis demonstrated that a unit change in the concentration of endotoxin across time was associated with a significant (p < 0.05) reduction in the bacteriological cell count. This analysis evidenced a significant time effect in the average log bacteriological cell count. Although bacterial growth was not detected in some water samples, endotoxin was present. Measurement of Gram-negative bacterial endotoxins is one of the methods that have been suggested as a rapid way of determining bacteriological water quality.
Microbiological contamination of cubicle curtains in an out-patient podiatry clinic
2010-01-01
Background Exposure to potential pathogens on contaminated healthcare garments and curtains can occur through direct or indirect contact. This study aimed to identify the microorganisms present on podiatry clinic curtains and measure the contamination pre and post a standard hospital laundry process. Method Baseline swabs were taken to determine colony counts present on cubical curtains before laundering. Curtains were swabbed again immediately after, one and three weeks post laundering. Total colony counts were calculated and compared to baseline, with identification of micro-organisms. Results Total colony counts increased very slightly by 3% immediately after laundry, which was not statistically significant, and declined significantly (p = 0.0002) by 56% one-week post laundry. Three weeks post laundry colony counts had increased by 16%; although clinically relevant, this was not statistically significant. The two most frequent microorganisms present throughout were Coagulase Negative Staphylococcus and Micrococcus species. Laundering was not completely effective, as both species demonstrated no significant change following laundry. Conclusion This work suggests current laundry procedures may not be 100% effective in killing all microorganisms found on curtains, although a delayed decrease in total colony counts was evident. Cubicle curtains may act as a reservoir for microorganisms creating potential for cross contamination. This highlights the need for additional cleaning methods to decrease the risk of cross infection and the importance of maintaining good hand hygiene. PMID:21087486
Predicting county-level cancer incidence rates and counts in the United States
Yu, Binbing
2018-01-01
Many countries, including the United States, publish predicted numbers of cancer incidence and death in current and future years for the whole country. These predictions provide important information on the cancer burden for cancer control planners, policymakers and the general public. Based on evidence from several empirical studies, the joinpoint (segmented-line linear regression) model has been adopted by the American Cancer Society to estimate the number of new cancer cases in the United States and in individual states since 2007. Recently, cancer incidence in smaller geographic regions such as counties and FIPS code regions is of increasing interest by local policymakers. The natural extension is to directly apply the joinpoint model to county-level cancer incidence data. The direct application has several drawbacks and its performance has not been evaluated. To address the concerns, we developed a spatial random-effects joinpoint model for county-level cancer incidence data. The proposed model was used to predict both cancer incidence rates and counts at the county level. The standard joinpoint model and the proposed method were compared through a validation study. The proposed method out-performed the standard joinpoint model for almost all cancer sites, especially for moderate or rare cancer sites and for counties with small population sizes. As an application, we predicted county-level prostate cancer incidence rates and counts for the year 2011 in Connecticut. PMID:23670947
Yolk formation in some Charadriiform birds
Roudybush, T.E.; Grau, C.R.; Petersen, M.R.; Ainley, D.G.; Hirsch, K.V.; Gilman, A.P.; Patten, S.M.
1979-01-01
By counting and measuring the major ova of breeding birds at autopsy and combining these data with time intervals between ovipositions, rough estimates have been made of the time required to form yolk in some non-captive birds (King 1973). Direct studies have been made in domestic fowl (Gallus gallus var. domesticus; Gilbert 1972), turkeys (Meleagris galloparvo; Bacon and Cherms 1968), and Common quail (Coturnix coturnix; Bacon and Koontz 1971), by feeding the birds a capsule containing dye each day, and counting dye rings in the yolks after the eggs have been hardcooked. Recently developed methods of fixing and staining eggs have revealed differences in yolk deposited during day and night, thus permitting another estimation of the number of days during which yolk was deposited, and without direct contact with the female (Grau 1976). In eggs from chickens and quail that have been fed dyes, yolk that stained darkly with dichromate was shown to be deposited during the active daytime feeding periods, while pale-staining yolk was deposited during the night. Thus, pairs of light and dark rings, which together take a day to be deposited, may be counted to estimate time of yolk formation.In the present study we have applied the yolk ring method of estimating the number of days during which the bulk of the yolk is deposited around the central white core (Grau 1976) to the eggs of some shorebirds, gulls, terns and alcids.
Tucker, George; Loh, Po-Ru; Berger, Bonnie
2013-10-04
Comprehensive protein-protein interaction (PPI) maps are a powerful resource for uncovering the molecular basis of genetic interactions and providing mechanistic insights. Over the past decade, high-throughput experimental techniques have been developed to generate PPI maps at proteome scale, first using yeast two-hybrid approaches and more recently via affinity purification combined with mass spectrometry (AP-MS). Unfortunately, data from both protocols are prone to both high false positive and false negative rates. To address these issues, many methods have been developed to post-process raw PPI data. However, with few exceptions, these methods only analyze binary experimental data (in which each potential interaction tested is deemed either observed or unobserved), neglecting quantitative information available from AP-MS such as spectral counts. We propose a novel method for incorporating quantitative information from AP-MS data into existing PPI inference methods that analyze binary interaction data. Our approach introduces a probabilistic framework that models the statistical noise inherent in observations of co-purifications. Using a sampling-based approach, we model the uncertainty of interactions with low spectral counts by generating an ensemble of possible alternative experimental outcomes. We then apply the existing method of choice to each alternative outcome and aggregate results over the ensemble. We validate our approach on three recent AP-MS data sets and demonstrate performance comparable to or better than state-of-the-art methods. Additionally, we provide an in-depth discussion comparing the theoretical bases of existing approaches and identify common aspects that may be key to their performance. Our sampling framework extends the existing body of work on PPI analysis using binary interaction data to apply to the richer quantitative data now commonly available through AP-MS assays. This framework is quite general, and many enhancements are likely possible. Fruitful future directions may include investigating more sophisticated schemes for converting spectral counts to probabilities and applying the framework to direct protein complex prediction methods.
NASA Technical Reports Server (NTRS)
Strayer, Richard F.; Hummerick, Mary E.; Richards, Jeffrey T.; McCoy, LaShelle E.; Roberts, Michael S.; Wheeler, Raymond M.
2011-01-01
The fate of space-generated solid wastes, including trash, for future missions is under consideration by NASA. Several potential treatment options are under active technology development. Potential fates for space-generated solid wastes: Storage without treatment; storage after treatment(s) including volume reduction, water recovery, sterilization, and recovery plus recycling of waste materials. For this study, a microbial characterization was made on trash returned from four recent STS missions. The material analyzed were 'Volume F' trash and other bags of accompanying trash. This is the second of two submitted papers on these wastes. This first one covered trash content, weight and water content. Upon receipt, usually within 2 days of landing, trash contents were catalogued and placed into categories: drink containers, food waste, personal hygiene items, and packaging materials, i.e., plastic film and duct tape. Microbial counts were obtained with cultivatable counts on agar media and direct counts using Acridine Orange fluorescent stain (AODC). Trash bag surfaces, 25 square cm , were also sampled. Direct counts were approximately 1 x 10(exp 6) microbes/square cm and cultivatable counts ranged from 1 x 10 to 1 X 10(exp 4) microbes/ square cm-2. Aerobic microbes, aerobic sporeformers, and yeasts plus molds were common for all four missions. Waste items from each category were placed into sterile ziplock bags and 1.5 L sterile DI water added. These were then dispersed by hand shaking for 2 min. prior to inoculation of count media or determining AODC. In general, cultivatable microbes were found in drinks, food wastes, and personal hygiene items. Direct counts were usually higher than cultivatable counts. Some pathogens were found: Staphylococcus auerus, Escherichia coli (fecal wastes). Count ranges: drink pouches - AODC 2 x 10(exp 6) to 1 X 10(exp 8) g(sub fw) (exp -1); cultivatable counts variable between missions; food wastes: Direct counts were close to aerobic plate counts. Counts ranged from 10(exp 6) to 10(exp 9) per g(sub fw). Identities of isolates from cultivation media were obtained using a Biolog Microbial ID System or microSEQ molecular ID methodology using an ABI3130 gene analyzer.
The solution of linear systems of equations with a structural analysis code on the NAS CRAY-2
NASA Technical Reports Server (NTRS)
Poole, Eugene L.; Overman, Andrea L.
1988-01-01
Two methods for solving linear systems of equations on the NAS Cray-2 are described. One is a direct method; the other is an iterative method. Both methods exploit the architecture of the Cray-2, particularly the vectorization, and are aimed at structural analysis applications. To demonstrate and evaluate the methods, they were installed in a finite element structural analysis code denoted the Computational Structural Mechanics (CSM) Testbed. A description of the techniques used to integrate the two solvers into the Testbed is given. Storage schemes, memory requirements, operation counts, and reformatting procedures are discussed. Finally, results from the new methods are compared with results from the initial Testbed sparse Choleski equation solver for three structural analysis problems. The new direct solvers described achieve the highest computational rates of the methods compared. The new iterative methods are not able to achieve as high computation rates as the vectorized direct solvers but are best for well conditioned problems which require fewer iterations to converge to the solution.
Makkaew, P; Miller, M; Cromar, N J; Fallowfield, H J
2017-04-01
This study investigated the volume of wastewater retained on the surface of three different varieties of lettuce, Iceberg, Cos, and Oak leaf, following submersion in wastewater of different microbial qualities (10, 10 2 , 10 3 , and 10 4 E. coli MPN/100 mL) as a surrogate method for estimation of contamination of spray-irrigated lettuce. Uniquely, Escherichia coli was enumerated, after submersion, on both the outer and inner leaves and in a composite sample of lettuce. E. coli were enumerated using two techniques. Firstly, from samples of leaves - the direct method. Secondly, using an indirect method, where the E. coli concentrations were estimated from the volume of wastewater retained by the lettuce and the E. coli concentration of the wastewater. The results showed that different varieties of lettuce retained significantly different volumes of wastewater (p < 0.01). No statistical differences (p > 0.01) were detected between E. coli counts obtained from different parts of lettuce, nor between the direct and indirect enumeration methods. Statistically significant linear relationships were derived relating the E. coli concentration of the wastewater in which the lettuces were submerged to the subsequent E. coli count on each variety the lettuce.
Gibson, Mhairi A; Gurmu, Eshetu; Cobo, Beatriz; Rueda, María M; Scott, Isabel M
2018-01-01
Female genital cutting (FGC) has major implications for women's physical, sexual and psychological health, and eliminating the practice is a key target for public health policy-makers. To date one of the main barriers to achieving this has been an inability to infer privately-held views on FGC within communities where it is prevalent. As a sensitive (and often illegal) topic, people are anticipated to hide their true support for the practice when questioned directly. Here we use an indirect questioning method (unmatched count technique) to identify hidden support for FGC in a rural South Central Ethiopian community where the practice is common, but thought to be in decline. Employing a socio-demographic household survey of 1620 Arsi Oromo adults, which incorporated both direct and indirect direct response (unmatched count) techniques we compare directly-stated versus privately-held views in support of FGC, and individual variation in responses by age, gender and education and target female (daughters versus daughters-in-law). Both genders express low support for FGC when questioned directly, while indirect methods reveal substantially higher acceptance (of cutting both daughters and daughters-in-law). Educated adults (those who have attended school) are privately more supportive of the practice than they are prepared to admit openly to an interviewer, indicating that education may heighten secrecy rather than decrease support for FGC. Older individuals hold the strongest views in favour of FGC (particularly educated older males), but they are also more inclined to conceal their support for FGC when questioned directly. As these elders represent the most influential members of society, their hidden support for FGC may constitute a pivotal barrier to eliminating the practice in this community. Our results demonstrate the great potential for indirect questioning methods to advance knowledge and inform policy on culturally-sensitive topics like FGC; providing more reliable data and improving understanding of the "true" drivers of FGC.
Si-strip photon counting detectors for contrast-enhanced spectral mammography
NASA Astrophysics Data System (ADS)
Chen, Buxin; Reiser, Ingrid; Wessel, Jan C.; Malakhov, Nail; Wawrzyniak, Gregor; Hartsough, Neal E.; Gandhi, Thulasi; Chen, Chin-Tu; Iwanczyk, Jan S.; Barber, William C.
2015-08-01
We report on the development of silicon strip detectors for energy-resolved clinical mammography. Typically, X-ray integrating detectors based on scintillating cesium iodide CsI(Tl) or amorphous selenium (a-Se) are used in most commercial systems. Recently, mammography instrumentation has been introduced based on photon counting Si strip detectors. The required performance for mammography in terms of the output count rate, spatial resolution, and dynamic range must be obtained with sufficient field of view for the application, thus requiring the tiling of pixel arrays and particular scanning techniques. Room temperature Si strip detector, operating as direct conversion x-ray sensors, can provide the required speed when connected to application specific integrated circuits (ASICs) operating at fast peaking times with multiple fixed thresholds per pixel, provided that the sensors are designed for rapid signal formation across the X-ray energy ranges of the application. We present our methods and results from the optimization of Si-strip detectors for contrast enhanced spectral mammography. We describe the method being developed for quantifying iodine contrast using the energy-resolved detector with fixed thresholds. We demonstrate the feasibility of the method by scanning an iodine phantom with clinically relevant contrast levels.
COMPARISON OF THE EFFECT OF AMERICAN BISON AND CATTLE ON PASTURE AND DIRECT ACCESS STREAMS
If the Bison are managed in a low impact method then we can count on meat that is free of antibiotics, added hormones, and other industry byproducts. In fact, Federal regulations prohibit the use of artificial growth hormones in bison, and industry protocols prohibit the use ...
77 FR 55166 - Airworthiness Directives; Sikorsky Aircraft Corporation (Sikorsky) Model Helicopters
Federal Register 2010, 2011, 2012, 2013, 2014
2012-09-07
... ``partial cycle event,'' specify a method of calculating the low cycle fatigue (LCF) life limit using... or continuing to count the full and partial low fatigue cycle events and recording on the component... distinction; and 4. Will not have a significant economic impact, positive or negative, on a substantial number...
Cho, H-M; Ding, H; Ziemer, B P; Molloi, S
2014-12-07
Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using x-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for x-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm(2) in detection area. The angular dependence of x-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded x-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of x-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of x-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic x-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the x-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory.
NASA Astrophysics Data System (ADS)
Cho, H.-M.; Ding, H.; Ziemer, BP; Molloi, S.
2014-12-01
Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using x-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for x-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm2 in detection area. The angular dependence of x-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded x-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of x-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of x-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic x-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the x-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory.
Cho, H-M; Ding, H; Ziemer, BP; Molloi, S
2014-01-01
Accurate energy calibration is critical for the application of energy-resolved photon-counting detectors in spectral imaging. The aim of this study is to investigate the feasibility of energy response calibration and characterization of a photon-counting detector using X-ray fluorescence. A comprehensive Monte Carlo simulation study was performed using Geant4 Application for Tomographic Emission (GATE) to investigate the optimal technique for X-ray fluorescence calibration. Simulations were conducted using a 100 kVp tungsten-anode spectra with 2.7 mm Al filter for a single pixel cadmium telluride (CdTe) detector with 3 × 3 mm2 in detection area. The angular dependence of X-ray fluorescence and scatter background was investigated by varying the detection angle from 20° to 170° with respect to the beam direction. The effects of the detector material, shape, and size on the recorded X-ray fluorescence were investigated. The fluorescent material size effect was considered with and without the container for the fluorescent material. In order to provide validation for the simulation result, the angular dependence of X-ray fluorescence from five fluorescent materials was experimentally measured using a spectrometer. Finally, eleven of the fluorescent materials were used for energy calibration of a CZT-based photon-counting detector. The optimal detection angle was determined to be approximately at 120° with respect to the beam direction, which showed the highest fluorescence to scatter ratio (FSR) with a weak dependence on the fluorescent material size. The feasibility of X-ray fluorescence for energy calibration of photon-counting detectors in the diagnostic X-ray energy range was verified by successfully calibrating the energy response of a CZT-based photon-counting detector. The results of this study can be used as a guideline to implement the X-ray fluorescence calibration method for photon-counting detectors in a typical imaging laboratory. PMID:25369288
Optimization of low-level LS counter Quantulus 1220 for tritium determination in water samples
NASA Astrophysics Data System (ADS)
Jakonić, Ivana; Todorović, Natasa; Nikolov, Jovana; Bronić, Ines Krajcar; Tenjović, Branislava; Vesković, Miroslav
2014-05-01
Liquid scintillation counting (LSC) is the most commonly used technique for measuring tritium. To optimize tritium analysis in waters by ultra-low background liquid scintillation spectrometer Quantulus 1220 the optimization of sample/scintillant ratio, choice of appropriate scintillation cocktail and comparison of their efficiency, background and minimal detectable activity (MDA), the effect of chemi- and photoluminescence and combination of scintillant/vial were performed. ASTM D4107-08 (2006) method had been successfully applied in our laboratory for two years. During our last preparation of samples a serious quench effect in count rates of samples that could be consequence of possible contamination by DMSO was noticed. The goal of this paper is to demonstrate development of new direct method in our laboratory proposed by Pujol and Sanchez-Cabeza (1999), which turned out to be faster and simpler than ASTM method while we are dealing with problem of neutralization of DMSO in apparatus. The minimum detectable activity achieved was 2.0 Bq l-1 for a total counting time of 300 min. In order to test the optimization of system for this method tritium level was determined in Danube river samples and also for several samples within intercomparison with Ruđer Bošković Institute (IRB).
Oxide Ceramic Fibers by the Sol-Gel Methods
1989-02-10
AFWAL-TR-88-4199 OXIDE CERAMIC FIBERS BY THE SOL-GEL METHOD J . D. Mackenzie If) K. Ono The Regents of the University of California (Los Angeles) V...METHOD 12. PERSONAL AUTHOR(S) J . D. MACKENZIE, K. ONO 13a. TYPE OF REPORT 13b. TIME COVERED 114. DATE OF REPORT (Year,Month, Day) 15. PAGE COUNT...to Mary Colby who performed, under the direction of J . D. Mackenzie, the bulk of the experimental studies and contributed extensively to the
Estimating adult sex ratios in nature.
Ancona, Sergio; Dénes, Francisco V; Krüger, Oliver; Székely, Tamás; Beissinger, Steven R
2017-09-19
Adult sex ratio (ASR, the proportion of males in the adult population) is a central concept in population and evolutionary biology, and is also emerging as a major factor influencing mate choice, pair bonding and parental cooperation in both human and non-human societies. However, estimating ASR is fraught with difficulties stemming from the effects of spatial and temporal variation in the numbers of males and females, and detection/capture probabilities that differ between the sexes. Here, we critically evaluate methods for estimating ASR in wild animal populations, reviewing how recent statistical advances can be applied to handle some of these challenges. We review methods that directly account for detection differences between the sexes using counts of unmarked individuals (observed, trapped or killed) and counts of marked individuals using mark-recapture models. We review a third class of methods that do not directly sample the number of males and females, but instead estimate the sex ratio indirectly using relationships that emerge from demographic measures, such as survival, age structure, reproduction and assumed dynamics. We recommend that detection-based methods be used for estimating ASR in most situations, and point out that studies are needed that compare different ASR estimation methods and control for sex differences in dispersal.This article is part of the themed issue 'Adult sex ratios and reproductive decisions: a critical re-examination of sex differences in human and animal societies'. © 2017 The Author(s).
NASA Astrophysics Data System (ADS)
Alves, Tavvs Micael
Soybean aphid, Aphis glycines (Hemiptera: Aphididae) is the primary insect pest of soybean in the northcentral United States. Soybean aphid may cause stunted plants, leaf discoloration, plant death, and decrease soybean yield by 40%. Sampling plans have been developed for supporting soybean aphid management. However, growers' perception about time involved in direct insect counts has been contributing to a lower adoption of traditional pest scouting methods and may be associated with the use of prophylactic insecticide applications in soybean. Remote sensing of plant spectral (light-derived) responses to soybean aphid feeding is a promising alternative to estimate injury without direct insect counts and, thus, increase adoption and efficiency of scouting programs. This research explored the use of remote sensing of soybean reflectance for detection of soybean aphids and showed that foliar insecticides may have implications for subsequent use of soybean spectral reflectance for pest detection. (Abstract shortened by ProQuest.).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Aab, A.; Abreu, P.; Aglietta, M.
Here, AMIGA (Auger Muons and Infill for the Ground Array) is an upgrade of the Pierre Auger Observatory designed to extend its energy range of detection and to directly measure the muon content of the cosmic ray primary particle showers. The array will be formed by an infill of surface water-Cherenkov detectors associated with buried scintillation counters employed for muon counting. Each counter is composed of three scintillation modules, with a 10 m 2 detection area per module. In this paper, a new generation of detectors, replacing the current multi-pixel photomultiplier tube (PMT) with silicon photo sensors (aka. SiPMs), ismore » proposed. The selection of the new device and its front-end electronics is explained. A method to calibrate the counting system that ensures the performance of the detector is detailed. This method has the advantage of being able to be carried out in a remote place such as the one where the detectors are deployed. High efficiency results, i.e. 98% efficiency for the highest tested overvoltage, combined with a low probability of accidental counting (~2%), show a promising performance for this new system.« less
Detection of microbial concentration in ice-cream using the impedance technique.
Grossi, M; Lanzoni, M; Pompei, A; Lazzarini, R; Matteuzzi, D; Riccò, B
2008-06-15
The detection of microbial concentration, essential for safe and high quality food products, is traditionally made with the plate count technique, that is reliable, but also slow and not easily realized in the automatic form, as required for direct use in industrial machines. To this purpose, the method based on impedance measurements represents an attractive alternative since it can produce results in about 10h, instead of the 24-48h needed by standard plate counts and can be easily realized in automatic form. In this paper such a method has been experimentally studied in the case of ice-cream products. In particular, all main ice-cream compositions of real interest have been considered and no nutrient media has been used to dilute the samples. A measurement set-up has been realized using benchtop instruments for impedance measurements on samples whose bacteria concentration was independently measured by means of standard plate counts. The obtained results clearly indicate that impedance measurement represents a feasible and reliable technique to detect total microbial concentration in ice-cream, suitable to be implemented as an embedded system for industrial machines.
MEMS PolyMUMPS-Based Miniature Microphone for Directional Sound Sensing
2007-09-01
of the translating mode Phir=-atan((2*wr*er*w)/(wr^2-w^2));% Phase constant rocking Phit =-atan((2*wt*et*w)/(wt^2-w^2));% Phase constant translating...2.5e-6)+1 Yl(count)=8e6*(At*sin(w.*t(count)+ Phit ) + Ar*cos(w.*t(count)+Phir)); %left membrane displacement as a function of time in micrometers...Xl(count)=-(((.5)^2-Yl(count).^2).^.5); Yr(count)=8e6*(At*sin(w.*t(count)+ Phit ) - Ar*cos(w.*t(count)+Phir)); %right membrane displacement
Measuring larval nematode contamination on cattle pastures: Comparing two herbage sampling methods.
Verschave, S H; Levecke, B; Duchateau, L; Vercruysse, J; Charlier, J
2015-06-15
Assessing levels of pasture larval contamination is frequently used to study the population dynamics of the free-living stages of parasitic nematodes of livestock. Direct quantification of infective larvae (L3) on herbage is the most applied method to measure pasture larval contamination. However, herbage collection remains labour intensive and there is a lack of studies addressing the variation induced by the sampling method and the required sample size. The aim of this study was (1) to compare two different sampling methods in terms of pasture larval count results and time required to sample, (2) to assess the amount of variation in larval counts at the level of sample plot, pasture and season, respectively and (3) to calculate the required sample size to assess pasture larval contamination with a predefined precision using random plots across pasture. Eight young stock pastures of different commercial dairy herds were sampled in three consecutive seasons during the grazing season (spring, summer and autumn). On each pasture, herbage samples were collected through both a double-crossed W-transect with samples taken every 10 steps (method 1) and four random located plots of 0.16 m(2) with collection of all herbage within the plot (method 2). The average (± standard deviation (SD)) pasture larval contamination using sampling methods 1 and 2 was 325 (± 479) and 305 (± 444)L3/kg dry herbage (DH), respectively. Large discrepancies in pasture larval counts of the same pasture and season were often seen between methods, but no significant difference (P = 0.38) in larval counts between methods was found. Less time was required to collect samples with method 2. This difference in collection time between methods was most pronounced for pastures with a surface area larger than 1 ha. The variation in pasture larval counts from samples generated by random plot sampling was mainly due to the repeated measurements on the same pasture in the same season (residual variance component = 6.2), rather than due to pasture (variance component = 0.55) or season (variance component = 0.15). Using the observed distribution of L3, the required sample size (i.e. number of plots per pasture) for sampling a pasture through random plots with a particular precision was simulated. A higher relative precision was acquired when estimating PLC on pastures with a high larval contamination and a low level of aggregation compared to pastures with a low larval contamination when the same sample size was applied. In the future, herbage sampling through random plots across pasture (method 2) seems a promising method to develop further as no significant difference in counts between the methods was found and this method was less time consuming. Copyright © 2015 Elsevier B.V. All rights reserved.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Miller, Erin A.; Robinson, Sean M.; Anderson, Kevin K.
2015-01-19
Here we present a novel technique for the localization of radiological sources in urban or rural environments from an aerial platform. The technique is based on a Bayesian approach to localization, in which measured count rates in a time series are compared with predicted count rates from a series of pre-calculated test sources to define likelihood. Furthermore, this technique is expanded by using a localized treatment with a limited field of view (FOV), coupled with a likelihood ratio reevaluation, allowing for real-time computation on commodity hardware for arbitrarily complex detector models and terrain. In particular, detectors with inherent asymmetry ofmore » response (such as those employing internal collimation or self-shielding for enhanced directional awareness) are leveraged by this approach to provide improved localization. Our results from the localization technique are shown for simulated flight data using monolithic as well as directionally-aware detector models, and the capability of the methodology to locate radioisotopes is estimated for several test cases. This localization technique is shown to facilitate urban search by allowing quick and adaptive estimates of source location, in many cases from a single flyover near a source. In particular, this method represents a significant advancement from earlier methods like full-field Bayesian likelihood, which is not generally fast enough to allow for broad-field search in real time, and highest-net-counts estimation, which has a localization error that depends strongly on flight path and cannot generally operate without exhaustive search« less
Diffusion processes in tumors: A nuclear medicine approach
NASA Astrophysics Data System (ADS)
Amaya, Helman
2016-07-01
The number of counts used in nuclear medicine imaging techniques, only provides physical information about the desintegration of the nucleus present in the the radiotracer molecules that were uptaken in a particular anatomical region, but that information is not a real metabolic information. For this reason a mathematical method was used to find a correlation between number of counts and 18F-FDG mass concentration. This correlation allows a better interpretation of the results obtained in the study of diffusive processes in an agar phantom, and based on it, an image from the PETCETIX DICOM sample image set from OsiriX-viewer software was processed. PET-CT gradient magnitude and Laplacian images could show direct information on diffusive processes for radiopharmaceuticals that enter into the cells by simple diffusion. In the case of the radiopharmaceutical 18F-FDG is necessary to include pharmacokinetic models, to make a correct interpretation of the gradient magnitude and Laplacian of counts images.
Real-time multi-mode neutron multiplicity counter
Rowland, Mark S; Alvarez, Raymond A
2013-02-26
Embodiments are directed to a digital data acquisition method that collects data regarding nuclear fission at high rates and performs real-time preprocessing of large volumes of data into directly useable forms for use in a system that performs non-destructive assaying of nuclear material and assemblies for mass and multiplication of special nuclear material (SNM). Pulses from a multi-detector array are fed in parallel to individual inputs that are tied to individual bits in a digital word. Data is collected by loading a word at the individual bit level in parallel, to reduce the latency associated with current shift-register systems. The word is read at regular intervals, all bits simultaneously, with no manipulation. The word is passed to a number of storage locations for subsequent processing, thereby removing the front-end problem of pulse pileup. The word is used simultaneously in several internal processing schemes that assemble the data in a number of more directly useable forms. The detector includes a multi-mode counter that executes a number of different count algorithms in parallel to determine different attributes of the count data.
Survey of methods for calculating sensitivity of general eigenproblems
NASA Technical Reports Server (NTRS)
Murthy, Durbha V.; Haftka, Raphael T.
1987-01-01
A survey of methods for sensitivity analysis of the algebraic eigenvalue problem for non-Hermitian matrices is presented. In addition, a modification of one method based on a better normalizing condition is proposed. Methods are classified as Direct or Adjoint and are evaluated for efficiency. Operation counts are presented in terms of matrix size, number of design variables and number of eigenvalues and eigenvectors of interest. The effect of the sparsity of the matrix and its derivatives is also considered, and typical solution times are given. General guidelines are established for the selection of the most efficient method.
Stein, A; Shufaro, Y; Hadar, S; Fisch, B; Pinkas, H
2015-03-01
The existing methods for cryopreservation of very low count sperm samples are complex and sub-optimal for individual spermatozoa. Our purpose is to establish an effective simple method for cryoprotecting individual spermatozoa. Samples from patients with OTA were mixed with TYB or HEPES-buffered salt solution with glycerol + glucose and placed on a Cryolock that was plunged directly into liquid nitrogen or exposed to its vapors. Thawing was performed by direct immersion into a drop of warmed medium. The favorable method was tested on diluted samples (10-50 cells) and leftover TESE specimens from patients with azoospermia. Cryopreservation was considered successful if >30 spermatozoa, (>3 motile), or >5 spermatozoa (>1 motile) in diluted and TESE samples, were detected post-thawing. A significantly higher survival rate of seminal spermatozoa was obtained when using the Cryolock with TYB and freezing with liquid nitrogen vapor, compared to HEPES glycerol-glucose (95 vs. 35% respectively). Plunging the Cryolock into liquid nitrogen was detrimental. Cryolock combined with TYB cryoprotection and liquid nitrogen vapor freezing was highly effective for cryopreservation of individual spermatozoa in diluted and TESE samples. The Cryolock may serve for freezing very low-count sperm samples and individual spermatozoa. This method offers simplicity, efficacy, use of available materials, without requiring micromanipulation equipment or skills. © 2015 American Society of Andrology and European Academy of Andrology.
Characterization of photon-counting multislit breast tomosynthesis.
Berggren, Karl; Cederström, Björn; Lundqvist, Mats; Fredenberg, Erik
2018-02-01
It has been shown that breast tomosynthesis may improve sensitivity and specificity compared to two-dimensional mammography, resulting in increased detection-rate of cancers or lowered call-back rates. The purpose of this study is to characterize a spectral photon-counting multislit breast tomosynthesis system that is able to do single-scan spectral imaging with multiple collimated x-ray beams. The system differs in many aspects compared to conventional tomosynthesis using energy-integrating flat-panel detectors. The investigated system was a prototype consisting of a dual-threshold photon-counting detector with 21 collimated line detectors scanning across the compressed breast. A review of the system is done in terms of detector, acquisition geometry, and reconstruction methods. Three reconstruction methods were used, simple back-projection, filtered back-projection and an iterative algebraic reconstruction technique. The image quality was evaluated by measuring the modulation transfer-function (MTF), normalized noise-power spectrum, detective quantum-efficiency (DQE), and artifact spread-function (ASF) on reconstructed spectral tomosynthesis images for a total-energy bin (defined by a low-energy threshold calibrated to remove electronic noise) and for a high-energy bin (with a threshold calibrated to split the spectrum in roughly equal parts). Acquisition was performed using a 29 kVp W/Al x-ray spectrum at a 0.24 mGy exposure. The difference in MTF between the two energy bins was negligible, that is, there was no energy dependence on resolution. The MTF dropped to 50% at 1.5 lp/mm to 2.3 lp/mm in the scan direction and 2.4 lp/mm to 3.3 lp/mm in the slit direction, depending on the reconstruction method. The full width at half maximum of the ASF was found to range from 13.8 mm to 18.0 mm for the different reconstruction methods. The zero-frequency DQE of the system was found to be 0.72. The fraction of counts in the high-energy bin was measured to be 59% of the total detected spectrum. Scantimes ranged from 4 s to 16.5 s depending on voltage and current settings. The characterized system generates spectral tomosynthesis images with a dual-energy photon-counting detector. Measurements show a high DQE, enabling high image quality at a low dose, which is beneficial for low-dose applications such as screening. The single-scan spectral images open up for applications such as quantitative material decomposition and contrast-enhanced tomosynthesis. © 2017 American Association of Physicists in Medicine.
Liu, Yanhong; Kong, Xiangyi; Wang, Wen; Fan, Fangfang; Zhang, Yan; Zhao, Min; Wang, Yi; Wang, Yupeng; Wang, Yu; Qin, Xianhui; Tang, Genfu; Wang, Binyan; Xu, Xiping; Hou, Fan Fan; Gao, Wei; Sun, Ningling; Li, Jianping; Venners, Scott A; Jiang, Shanqun; Huo, Yong
2017-01-01
The aim of the present study was to examine the association between peripheral differential leukocyte counts and dyslipidemia in a Chinese hypertensive population. A total of 10,866 patients with hypertension were enrolled for a comprehensive assessment of cardiovascular risk factors using data from the China Stroke Primary Prevention Trial. Plasma lipid levels and total leukocyte, neutrophil, and lymphocyte counts were determined according to standard methods. Peripheral differential leukocyte counts were consistently and positively associated with serum total cholesterol (TC), LDL cholesterol (LDL-C), and TG levels (all P < 0.001 for trend), while inversely associated with HDL cholesterol levels (P < 0.05 for trend). In subsequent analyses where serum lipids were dichotomized (dyslipidemia/normolipidemia), we found that patients in the highest quartile of total leukocyte count (≥7.6 × 10 9 cells/l) had 1.64 times the risk of high TG [95% confidence interval (CI): 1.46, 1.85], 1.34 times the risk of high TC (95% CI: 1.20, 1.50), and 1.24 times the risk of high LDL-C (95% CI: 1.12, 1.39) compared with their counterparts in the lowest quartile of total leukocyte count. Similar patterns were also observed with neutrophils and lymphocytes. In summary, these findings indicate that elevated differential leukocyte counts are directly associated with serum lipid levels and increased odds of dyslipidemia. Copyright © 2017 by the American Society for Biochemistry and Molecular Biology, Inc.
NASA Astrophysics Data System (ADS)
Dong, Kyung-Rae; Shim, Dong-Oh; Kim, Ho-Sung; Park, Yong-Soon; Chung, Woon-Kwan; Cho, Jae-Hwan
2013-02-01
In a nuclear medicine examination, methods to acquire a static image include the preset count method and the preset time method. The preset count method is used mainly in a static renal scan that utilizes 99 m Tc-DMSA (dimoercaptosuccinic acid) whereas the preset time method is used occasionally. When the preset count method is used, the same number of acquisition counts is acquired for each time, but the scan time varies. When the preset time method is used, the scan time is constant, but the number of counts acquired is not the same. Therefore, this study examined the dependence of the difference in information on the function and the shape of both sides of the kidneys on the counts acquired during a renal scan that utilizes 99 m Tc-DMSA. The study involved patients who had 40-60% relative function of one kidney among patients who underwent a 99 m Tc-DMSA renal scan in the Nuclear Medicine Department during the period from January 11 to March 31, 2012. A gamma camera was used to obtain the acquisition count continuously using 100,000 counts and 300,000 counts, and an acquisition time of 7 minutes (exceeding 300,000 counts). The function and the shape of the kidney were evaluated by measuring the relative function of both sides of the kidneys, the geometric mean, and the size of kidney before comparative analysis. According to the study results, neither the relative function nor the geometric mean of both sides of the kidneys varied significantly with the acquisition count. On the other hand, the size of the kidney tended to be larger with increasing acquisition count.
Li, Gang; Xu, Jiayun; Zhang, Jie
2015-01-01
Neutron radiation protection is an important research area because of the strong radiation biological effect of neutron field. The radiation dose of neutron is closely related to the neutron energy, and the connected relationship is a complex function of energy. For the low-level neutron radiation field (e.g. the Am-Be source), the commonly used commercial neutron dosimeter cannot always reflect the low-level dose rate, which is restricted by its own sensitivity limit and measuring range. In this paper, the intensity distribution of neutron field caused by a curie level Am-Be neutron source was investigated by measuring the count rates obtained through a 3 He proportional counter at different locations around the source. The results indicate that the count rates outside of the source room are negligible compared with the count rates measured in the source room. In the source room, 3 He proportional counter and neutron dosimeter were used to measure the count rates and dose rates respectively at different distances to the source. The results indicate that both the count rates and dose rates decrease exponentially with the increasing distance, and the dose rates measured by a commercial dosimeter are in good agreement with the results calculated by the Geant4 simulation within the inherent errors recommended by ICRP and IEC. Further studies presented in this paper indicate that the low-level neutron dose equivalent rates in the source room increase exponentially with the increasing low-energy neutron count rates when the source is lifted from the shield with different radiation intensities. Based on this relationship as well as the count rates measured at larger distance to the source, the dose rates can be calculated approximately by the extrapolation method. This principle can be used to estimate the low level neutron dose values in the source room which cannot be measured directly by a commercial dosimeter. Copyright © 2014 Elsevier Ltd. All rights reserved.
Morgan, J A; Winstanley, C; Pickup, R W; Jones, J G; Saunders, J R
1989-01-01
As a system for studying the fate of genetically engineered microorganisms in the environment, we have previously constructed recombinant plasmids encoding a xylE marker gene (C. Winstanley, J. A. W. Morgan, R. W. Pickup, J. G. Jones, and J. R. Saunders, Appl. Environ. Microbiol. 55:771-777, 1989). A series of direct membrane filter methods have been developed which facilitate the detection of bacterial cells harboring the xylE gene, its product, catechol 2,3-dioxygenase, and catechol 2,3-dioxygenase enzyme activity directly from water samples. These methods enable detection of recombinant populations at concentrations as low as 10(3) to 10(4) cells ml of lake water-1. Direct detection facilitates ecological studies of a range of bacterial strains containing the marker system in aquatic environments. The fate of a recombinant pseudomonad population in lake water was assessed by a combination of colony-forming ability, direct counts, and direct detection of the xylE gene and phenotypic expression of its product. Images PMID:2604395
Uz, Zühre; van Gulik, Thomas M; Aydemirli, Mehtap Derya; Guerci, Philippe; Ince, Yasin; Cuppen, Diede V; Ergin, Bulent; Aksu, Ugur; de Mol, Bas A; Ince, Can
2018-03-08
Leukocyte recruitment and adhesion to the endothelium are hallmarks of systemic inflammation that manifest in a wide range of diseases. At present, no method is available to directly measure leukocyte kinetics at the bedside. In this study, we validate a new method to identify and quantify microcirculatory leukocytes observed by handheld vital microscopy (HVM) using space-time diagram (STD) analysis. Video clips (N=59) containing one capillary-post capillary venule (C-PCV) unit where leukocytes could be observed emanating from a capillary into a venule in cardiac surgery patients (N=20) were included. STD analysis and manual counting were used to quantify the number of leukocytes (total, rolling and non-rolling). Pearson's correlation and Bland-Altman analysis were used to determine agreement between the STDs and manual counting. For reproducibility, intra- and inter-observer coefficients of variation (CVs) were assessed. Leukocyte (rolling and non-rolling) and red blood cell velocities were assessed. The STDs and manual counting procedures for the quantification of rolling leukocytes showed good agreement (r=0.8197, P<0.0001), with a Bland-Altman analysis mean difference of -0.0 (-6.56; 6.56). The overall intra-observer CV for the STD method was 1.5%. The overall inter-observer CVs for the STD and the manual method were 5.6% and 9.4%, respectively. The non-rolling velocity was significantly higher than the rolling velocity (812{plus minus}519 µm/s vs 201{plus minus}149 µm/s, P=0.001). The STD results agreed with the manual counting procedure results, had a better reproducibility and could assess the leukocyte velocity. STD analysis using bedside HVM imaging presented a new methodology for quantifying leukocyte kinetics and functions in the microcirculation.
Hop limited epidemic-like information spreading in mobile social networks with selfish nodes
NASA Astrophysics Data System (ADS)
Wu, Yahui; Deng, Su; Huang, Hongbin
2013-07-01
Similar to epidemics, information can be transmitted directly among users in mobile social networks. Different from epidemics, we can control the spreading process by adjusting the corresponding parameters (e.g., hop count) directly. This paper proposes a theoretical model to evaluate the performance of an epidemic-like spreading algorithm, in which the maximal hop count of the information is limited. In addition, our model can be used to evaluate the impact of users’ selfish behavior. Simulations show the accuracy of our theoretical model. Numerical results show that the information hop count can have an important impact. In addition, the impact of selfish behavior is related to the information hop count.
Sampling western spruce budworm larvae by frequency of occurrence on lower crown branches.
R.R. Mason; R.C. Beckwith
1990-01-01
A sampling method was derived whereby budworm density can be estimated by the frequency of occurrence of larvae over a given threshold number instead of by direct counts on branch samples. The model used for converting frequencies to mean densities is appropriate for nonrandom as well as random distributions and, therefore, is applicable to all population densities of...
Allmér, Johan; Vasiliauskas, Rimvis; Ihrmark, Katarina; Stenlid, Jan; Dahlberg, Anders
2006-01-01
Wood-inhabiting fungi play a key role in forest ecosystems and constitute an essential part of forest biodiversity. We therefore examined the composition and abundance of wood-inhabiting fungi by three methods: sporocarp counts, mycelial culturing and direct amplification of internal transcribed spacer terminal restriction fragment length polymorphism from wood combined with sequencing of reference rDNA. Seven-year-old slash piles left after a thinning were analyzed in a 50-year-old Norway spruce plantation. Fifty-eight fungal species were detected from the piled branches and treetops. More species were revealed by sporocarp counts and cultured mycelia than by direct amplification from wood. In principle, sporocarp monitoring may reveal all fruiting taxa, but it poorly reflects their relative abundance in the wood. In contrast, terminal restriction fragment length polymorphism will record the most frequent fungal taxa in the wood, but it may overlook uncommon taxa. Culturing mycelia from wood gives a bias towards species favoured by the cultural medium. The results demonstrate the advantage and the limitations of these methods to be considered in analyses of fungal communities in wood.
Atac, M.; McKay, T.A.
1998-04-21
An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD. 13 figs.
Atac, Muzaffer; McKay, Timothy A.
1998-01-01
An imaging system is provided for direct detection of x-rays from an irradiated biological tissue. The imaging system includes an energy source for emitting x-rays toward the biological tissue and a charge coupled device (CCD) located immediately adjacent the biological tissue and arranged transverse to the direction of irradiation along which the x-rays travel. The CCD directly receives and detects the x-rays after passing through the biological tissue. The CCD is divided into a matrix of cells, each of which individually stores a count of x-rays directly detected by the cell. The imaging system further includes a pattern generator electrically coupled to the CCD for reading a count from each cell. A display device is provided for displaying an image representative of the count read by the pattern generator from the cells of the CCD.
Kumar, Roshan M; Pajanivel, R; Koteeswaran, G; Menon, Surendra K; Charles, Pravin Mv
2017-01-01
Asthma is a chronic inflammatory disorder of the airway with involvement of various cellular populations and release of many inflammatory mediators. Eosinophils and serum immunoglobulin E (IgE) are considered a good marker of airway inflammation in asthma. The correlation of clinical assessment with various markers of airway inflammation in asthma is not well established in the Indian population. This study aims to study the correlation of serum IgE, sputum eosinophil count, and peripheral eosinophil count with clinical severity of Asthma. This is a cross-sectional study involving 76 stable asthmatic patients of 18-60 years of age attending the pulmonary medicine OPD. Spirometry measured at baseline. Participants were categorized according to the GINA criteria based on clinical symptoms and pulmonary function test. Blood samples were collected for peripheral eosinophil count, serum IgE levels, and sputum samples for eosinophil count. All three parameters were compared with severity of asthma. The correlation of sputum eosinophil count, peripheral eosinophil count, and serum IgE with severity of asthma was analyzed by Pearson's Chi-square test, Fisher's exact test, and the correlation coefficient was reported together with standard error of the estimate. The mean age of patients in our study was 37.42 years and 56.6% were male. There was a significant inverse correlation between serum IgE levels and predicted forced expiratory volume 1 s (FEV1). Sputum eosinophilia was significantly seen in severe persistent asthma patients (19.7%). There was a significant inverse correlation between sputum eosinophil count and predicted FEV1and forced vital capacity. We also found there was a significant association between peripheral eosinophil count, sputum eosinophil count, and elevated serum IgE (g100 IU/mL) with severe persistent asthma. The assessment of sputum eosinophil count is simple, inexpensive, noninvasive, and direct measurement of airway inflammation. It could be the preferred method in monitoring airway inflammation and guided management in day-to-day practice.
Formation and resuscitation of viable but nonculturable Salmonella typhi.
Zeng, Bin; Zhao, Guozhong; Cao, Xiaohong; Yang, Zhen; Wang, Chunling; Hou, Lihua
2013-01-01
Salmonella typhi is a pathogen that causes the human disease of typhoid fever. The aim of this study was to investigate the viable but nonculturable (VBNC) state of S. typhi. Some samples were stimulated at 4°C or -20°C, while others were induced by different concentrations of CuSO4. Total cell counts remained constant throughout several days by acridine orange direct counting; however, plate counts declined to undetectable levels within 48 hours by plate counting at -20°C. The direct viable counts remained fairly constant at this level by direct viable counting. Carbon and nitrogen materials slowly decreased which indicated that a large population of cells existed in the VBNC state and entered the VBNC state in response to exposure to 0.01 or 0.015 mmol/L CuSO4 for more than 14 or 12 days, respectively. Adding 3% Tween 20 or 1% catalase enabled cells to become culturable again, with resuscitation times of 48 h and 24 h, respectively. The atomic force microscope results showed that cells gradually changed in shape from short rods to coccoids, and decreased in size when they entered the VBNC state. Further animal experiments suggested that resuscitated cells might regain pathogenicity.
A double-observer method for reducing bias in faecal pellet surveys of forest ungulates
Jenkins, K.J.; Manly, B.F.J.
2008-01-01
1. Faecal surveys are used widely to study variations in abundance and distribution of forest-dwelling mammals when direct enumeration is not feasible. The utility of faecal indices of abundance is limited, however, by observational bias and variation in faecal disappearance rates that obscure their relationship to population size. We developed methods to reduce variability in faecal surveys and improve reliability of faecal indices. 2. We used double-observer transect sampling to estimate observational bias of faecal surveys of Roosevelt elk Cervus elaphus roosevelti and Columbian black-tailed deer Odocoileus hemionus columbianus in Olympic National Park, Washington, USA. We also modelled differences in counts of faecal groups obtained from paired cleared and uncleared transect segments as a means to adjust standing crop faecal counts for a standard accumulation interval and to reduce bias resulting from variable decay rates. 3. Estimated detection probabilities of faecal groups ranged from < 0.2-1.0 depending upon the observer, whether the faecal group was from elk or deer, faecal group size, distance of the faecal group from the sampling transect, ground vegetation cover, and the interaction between faecal group size and distance from the transect. 4. Models of plot-clearing effects indicated that standing crop counts of deer faecal groups required 34% reduction on flat terrain and 53% reduction on sloping terrain to represent faeces accumulated over a standard 100-day interval, whereas counts of elk faecal groups required 0% and 46% reductions on flat and sloping terrain, respectively. 5. Synthesis and applications. Double-observer transect sampling provides a cost-effective means of reducing observational bias and variation in faecal decay rates that obscure the interpretation of faecal indices of large mammal abundance. Given the variation we observed in observational bias of faecal surveys and persistence of faeces, we emphasize the need for future researchers to account for these comparatively manageable sources of bias before comparing faecal indices spatially or temporally. Double-observer sampling methods are readily adaptable to study variations in faecal indices of large mammals at the scale of the large forest reserve, natural area, or other forested regions when direct estimation of populations is problematic. ?? 2008 The Authors.
Laser-Based Diagnostics for Transient Species in Hydrocarbon Flames
1989-12-01
Year , Monek Daey) IS. PAGE COUNT PniIFROM ll/R TO--UR 1 90R 236 16. SUPPLEMENTARY NOTATION 17. COSATI CODES 1S. SUBJECT TERMS (Comnwiu on rewew if...chemical mechanism is to apply species specific diagnostic methods directly to the combustion system of interest. In the past , most optical diagnostic...of the two important radicals HCO and C2H by LIF or absorption methods is several years in the future and will require futher basic studies
Method for nondestructive fuel assay of laser fusion targets
Farnum, Eugene H.; Fries, R. Jay
1976-01-01
A method for nondestructively determining the deuterium and tritium content of laser fusion targets by counting the x rays produced by the interaction of tritium beta particles with the walls of the microballoons used to contain the deuterium and tritium gas mixture under high pressure. The x rays provide a direct measure of the tritium content and a means for calculating the deuterium content using the initial known D-T ratio and the known deuterium and tritium diffusion rates.
Warren, Stuart R; Raisch, Dennis W; Campbell, Heather M; Guarino, Peter D; Kaufman, James S; Petrokaitis, Elizabeth; Goldfarb, David S; Gaziano, J Michael; Jamison, Rex L
2013-01-01
Assessment of adherence to study medications is a common challenge in clinical research. Counting unused study medication is the predominant method by which adherence is assessed in outpatient clinical trials but it has limitations that include questionable validity and burdens on research personnel. To compare capsule counts, patient questionnaire responses, and plasma drug levels as methods of determining adherence in a clinical trial that had 2056 participants and used centralized drug distribution and patient follow-up. Capsule counts from study medication bottles returned by participants and responses to questions regarding adherence during quarterly telephone interviews were averaged and compared. Both measures were compared to plasma drug levels obtained at the 3-month study visit of patients in the treatment group. Counts and questionnaire responses were converted to adherence rates (doses taken divided by days elapsed) and were categorized by stringent (≥85.7%) and liberal (≥71.4%) definitions. We calculated the prevalence-adjusted bias-adjusted kappa to assess agreement between the two measures. Using a pre-paid mailer, participants returned 76.0% of study medication bottles to the central pharmacy. Both capsule counts and questionnaire responses were available for 65.8% of participants and were used to assess adherence. Capsule counts identified more patients who were under-adherent (18.8% by the stringent definition and 7.5% by the liberal definition) than self-reports did (10.4% by the stringent definition and 2.1% by the liberal definition). The prevalence-adjusted bias-adjusted kappa was 0.58 (stringent) and 0.83 (liberal), indicating fair and very good agreement, respectively. Both measures were also in agreement with plasma drug levels determined at the 3-month visit (capsule counts: p = 0.005 for the stringent and p = 0.003 for the liberal definition; questionnaire: p = 0.002 for both adherence definitions). Inconsistent bottle returns and incomplete notations of medication start and stop dates resulted in missing data but exploratory missing data analyses showed no reason to believe that the missing data resulted in systematic bias. Depending upon the definition of adherence, there was fair to very good agreement between questionnaire results and capsule counts among returned study bottles, confirmed by plasma drug levels. We conclude that a self-report of medication adherence is potentially comparable to capsule counts as a method of assessing adherence in a clinical trial, if a relatively low adherence threshold is acceptable, but adherence should be confirmed by other measures if a high adherence threshold is required.
Pettipher, Graham L.; Mansell, Roderick; McKinnon, Charles H.; Cousins, Christina M.
1980-01-01
Membrane filtration and epifluorescent microscopy were used for the direct enumeration of bacteria in raw milk. Somatic cells were lysed by treatment with trypsin and Triton X-100 so that 2 ml of milk containing up to 5 × 106 somatic cells/ml could be filtered. The majority of the bacteria (ca. 80%) remained intact and were concentrated on the membrane. After being stained with acridine organe, the bacteria fluoresced under ultraviolet light and could easily be counted. The clump count of orange fluorescing cells on the membrane correlated well (r = 0.91) with the corresponding plate count for farm, tanker, and silo milks. Differences between counts obtained by different operators and between the membrane clump count and plate count were not significant. The technique is rapid, taking less than 25 min, inexpensive, costing less than 50 cents per sample, and is suitable for milks containing 5 × 103 to 5 × 108 bacteria per ml. Images PMID:16345515
Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set
DOE Office of Scientific and Technical Information (OSTI.GOV)
Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.
Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less
Alpha Air Sample Counting Efficiency Versus Dust Loading: Evaluation of a Large Data Set
Hogue, M. G.; Gause-Lott, S. M.; Owensby, B. N.; ...
2018-03-03
Dust loading on air sample filters is known to cause a loss of efficiency for direct counting of alpha activity on the filters, but the amount of dust loading and the correction factor needed to account for attenuated alpha particles is difficult to assess. In this paper, correction factors are developed by statistical analysis of a large database of air sample results for a uranium and plutonium processing facility at the Savannah River Site. As is typically the case, dust-loading data is not directly available, but sample volume is found to be a reasonable proxy measure; the amount of dustmore » loading is inferred by a combination of the derived correction factors and a Monte Carlo model. The technique compares the distribution of activity ratios [beta/(beta + alpha)] by volume and applies a range of correction factors on the raw alpha count rate. The best-fit results with this method are compared with MCNP modeling of activity uniformly deposited in the dust and analytical laboratory results of digested filters. Finally, a linear fit is proposed to evenly-deposited alpha activity collected on filters with dust loading over a range of about 2 mg cm -2 to 1,000 mg cm -2.« less
Increasing the Efficiency of Electron Microprobe Measurements of Minor and Trace Elements in Rutile
NASA Astrophysics Data System (ADS)
Neill, O. K.; Mattinson, C. G.; Donovan, J.; Hernández Uribe, D.; Sains, A.
2016-12-01
Minor and trace element contents of rutile, an accessory mineral found in numerous lithologic settings, has many applications for interpreting earth systems. While these applications vary widely, they share a need for precise and accurate elemental measurements. The electron microprobe can be used to measure rutile compositions, although long X-ray counting times are necessary to achieve acceptable precision. Continuum ("background") intensity can be estimated using the iterative Mean Atomic Number (MAN) method of Donovan and Tingle (1996), obviating the need for direct off-peak background measurements, and reducing counting times by half. For this study, several natural and synthetic rutiles were measured by electron microprobe. Data was collected once but reduced twice, using off-peak and an MAN background corrections, allowing direct comparison of the two methods without influence of other variables (counting time, analyte homogeneity, beam current, calibration standards, etc.). These measurements show that, if a "blank" correction (Donovan et al., 2011, 2016) is used, minor and trace elements of interest can be measured in rutile using the MAN background method in half the time of traditional off-peak measurements, without sacrificing accuracy or precision (Figure 1). This method has already been applied to Zr-in-rutile thermometry of ultra-high pressure metamorphic rocks from the North Qaidam terrane in northwest China. Finally, secondary fluorescence of adjacent phases by continuum X-rays can lead to artificially elevated concentrations. For example, when measuring Zr, care should be taken to avoid analytical spots within 100 microns of zircon or baddeleyite crystals. References: 1) J.J. Donovan and T.N Tingle (1996) J. Microscopy, 2(1), 1-7 2) J.J. Donovan, H.A. Lowers, and B.G. Rusk (2011) Am. Mineral., 96, 274282 3) J.J. Donovan, J.W. Singer and J.T. Armstrong (2016) Am. Mineral., 101, 1839-1853 4) G.L. Lovizotto et al. (2009) Chem. Geol., 261, 346-369
Evaluation of mouse red blood cell and platelet counting with an automated hematology analyzer.
Fukuda, Teruko; Asou, Eri; Nogi, Kimiko; Goto, Kazuo
2017-10-07
An evaluation of mouse red blood cell (RBC) and platelet (PLT) counting with an automated hematology analyzer was performed with three strains of mice, C57BL/6 (B6), BALB/c (BALB) and DBA/2 (D2). There were no significant differences in RBC and PLT counts between manual and automated optical methods in any of the samples, except for D2 mice. For D2, RBC counts obtained using the manual method were significantly lower than those obtained using the automated optical method (P<0.05), and PLT counts obtained using the manual method were higher than those obtained using the automated optical method (P<0.05). An automated hematology analyzer can be used for RBC and PLT counting; however, an appropriate method should be selected when D2 mice samples are used.
Tabor, P S; Neihof, R A
1982-10-01
We report a method which combines epifluorescence microscopy and microautoradiography to determine both the total number of microorganisms in natural water populations and those individual organisms active in the uptake of specific substrates. After incubation with H-labeled substrate, the sample is filtered and, while still on the filter, mounted directly in a film of autoradiographic emulsion on a microscope slide. The microautoradiogram is processed and stained with acridine orange, and, subsequently, the filter is removed before microscopic observation. This novel preparation resulted in increased accuracy in direct counts made from the autoradiogram, improved sensitivity in the recognition of uptake-active (H-labeled) organisms, and enumeration of a significantly greater number of labeled organisms compared with corresponding samples prepared by a previously reported method.
Tabor, Paul S.; Neihof, Rex A.
1982-01-01
We report a method which combines epifluorescence microscopy and microautoradiography to determine both the total number of microorganisms in natural water populations and those individual organisms active in the uptake of specific substrates. After incubation with 3H-labeled substrate, the sample is filtered and, while still on the filter, mounted directly in a film of autoradiographic emulsion on a microscope slide. The microautoradiogram is processed and stained with acridine orange, and, subsequently, the filter is removed before microscopic observation. This novel preparation resulted in increased accuracy in direct counts made from the autoradiogram, improved sensitivity in the recognition of uptake-active (3H-labeled) organisms, and enumeration of a significantly greater number of labeled organisms compared with corresponding samples prepared by a previously reported method. Images PMID:16346120
Jang, Min Hye; Kim, Hyun Jung; Chung, Yul Ri; Lee, Yangkyu
2017-01-01
In spite of the usefulness of the Ki-67 labeling index (LI) as a prognostic and predictive marker in breast cancer, its clinical application remains limited due to variability in its measurement and the absence of a standard method of interpretation. This study was designed to compare the two methods of assessing Ki-67 LI: the average method vs. the hot spot method and thus to determine which method is more appropriate in predicting prognosis of luminal/HER2-negative breast cancers. Ki-67 LIs were calculated by direct counting of three representative areas of 493 luminal/HER2-negative breast cancers using the two methods. We calculated the differences in the Ki-67 LIs (ΔKi-67) between the two methods and the ratio of the Ki-67 LIs (H/A ratio) of the two methods. In addition, we compared the performance of the Ki-67 LIs obtained by the two methods as prognostic markers. ΔKi-67 ranged from 0.01% to 33.3% and the H/A ratio ranged from 1.0 to 2.6. Based on the receiver operating characteristic curve method, the predictive powers of the KI-67 LI measured by the two methods were similar (Area under curve: hot spot method, 0.711; average method, 0.700). In multivariate analysis, high Ki-67 LI based on either method was an independent poor prognostic factor, along with high T stage and node metastasis. However, in repeated counts, the hot spot method did not consistently classify tumors into high vs. low Ki-67 LI groups. In conclusion, both the average and hot spot method of evaluating Ki-67 LI have good predictive performances for tumor recurrence in luminal/HER2-negative breast cancers. However, we recommend using the average method for the present because of its greater reproducibility. PMID:28187177
Jang, Min Hye; Kim, Hyun Jung; Chung, Yul Ri; Lee, Yangkyu; Park, So Yeon
2017-01-01
In spite of the usefulness of the Ki-67 labeling index (LI) as a prognostic and predictive marker in breast cancer, its clinical application remains limited due to variability in its measurement and the absence of a standard method of interpretation. This study was designed to compare the two methods of assessing Ki-67 LI: the average method vs. the hot spot method and thus to determine which method is more appropriate in predicting prognosis of luminal/HER2-negative breast cancers. Ki-67 LIs were calculated by direct counting of three representative areas of 493 luminal/HER2-negative breast cancers using the two methods. We calculated the differences in the Ki-67 LIs (ΔKi-67) between the two methods and the ratio of the Ki-67 LIs (H/A ratio) of the two methods. In addition, we compared the performance of the Ki-67 LIs obtained by the two methods as prognostic markers. ΔKi-67 ranged from 0.01% to 33.3% and the H/A ratio ranged from 1.0 to 2.6. Based on the receiver operating characteristic curve method, the predictive powers of the KI-67 LI measured by the two methods were similar (Area under curve: hot spot method, 0.711; average method, 0.700). In multivariate analysis, high Ki-67 LI based on either method was an independent poor prognostic factor, along with high T stage and node metastasis. However, in repeated counts, the hot spot method did not consistently classify tumors into high vs. low Ki-67 LI groups. In conclusion, both the average and hot spot method of evaluating Ki-67 LI have good predictive performances for tumor recurrence in luminal/HER2-negative breast cancers. However, we recommend using the average method for the present because of its greater reproducibility.
NASA Astrophysics Data System (ADS)
Nohtomi, Akihiro; Wakabayashi, Genichiro
2015-11-01
We evaluated the accuracy of a self-activation method with iodine-containing scintillators in quantifying 128I generation in an activation detector; the self-activation method was recently proposed for photo-neutron on-line measurements around X-ray radiotherapy machines. Here, we consider the accuracy of determining the initial count rate R0, observed just after termination of neutron irradiation of the activation detector. The value R0 is directly related to the amount of activity generated by incident neutrons; the detection efficiency of radiation emitted from the activity should be taken into account for such an evaluation. Decay curves of 128I activity were numerically simulated by a computer program for various conditions including different initial count rates (R0) and background rates (RB), as well as counting statistical fluctuations. The data points sampled at minute intervals and integrated over the same period were fit by a non-linear least-squares fitting routine to obtain the value R0 as a fitting parameter with an associated uncertainty. The corresponding background rate RB was simultaneously calculated in the same fitting routine. Identical data sets were also evaluated by a well-known integration algorithm used for conventional activation methods and the results were compared with those of the proposed fitting method. When we fixed RB = 500 cpm, the relative uncertainty σR0 /R0 ≤ 0.02 was achieved for R0/RB ≥ 20 with 20 data points from 1 min to 20 min following the termination of neutron irradiation used in the fitting; σR0 /R0 ≤ 0.01 was achieved for R0/RB ≥ 50 with the same data points. Reasonable relative uncertainties to evaluate initial count rates were reached by the decay-fitting method using practically realistic sampling numbers. These results clarified the theoretical limits of the fitting method. The integration method was found to be potentially vulnerable to short-term variations in background levels, especially instantaneous contaminations by spike-like noise. The fitting method easily detects and removes such spike-like noise.
Identification of CSF fistulas by radionuclide counting
DOE Office of Scientific and Technical Information (OSTI.GOV)
Yamamoto, Y.; Kunishio, K.; Sunami, N.
1990-07-01
A radionuclide counting method, performed with the patient prone and the neck flexed, was used successfully to diagnose CSF rhinorrhea in two patients. A normal radionuclide ratio (radionuclide counts in pledget/radionuclide counts in 1-ml blood sample) was obtained in 11 normal control subjects. Significance was determined to be a ratio greater than 0.37. Use of radionuclide counting method of determining CSF rhinorrhea is recommended when other methods have failed to locate a site of leakage or when posttraumatic meningitis suggests subclinical CSF rhinorrhea.
HETEROTROPHIC PLATE COUNT (HPC) METHODOLOGY IN THE UNITED STATES
ABSTRACT
In the United States (U.S.), the history of bacterial plate counting methods used for water can be traced largely through Standard Methods for the Examination of Water and Wastewater (Standard Methods). The bacterial count method has evolved from the original St...
Mapping of Bird Distributions from Point Count Surveys
John R. Sauer; Grey W. Pendleton; Sandra Orsillo
1995-01-01
Maps generated from bird survey data are used for a variety of scientific purposes, but little is known about their bias and precision. We review methods for preparing maps from point count data and appropriate sampling methods for maps based on point counts. Maps based on point counts can be affected by bias associated with incomplete counts, primarily due to changes...
Platelet counting using the Coulter electronic counter.
Eggleton, M J; Sharp, A A
1963-03-01
A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.(1) The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed.
Choudhry, Priya
2016-01-01
Counting cells and colonies is an integral part of high-throughput screens and quantitative cellular assays. Due to its subjective and time-intensive nature, manual counting has hindered the adoption of cellular assays such as tumor spheroid formation in high-throughput screens. The objective of this study was to develop an automated method for quick and reliable counting of cells and colonies from digital images. For this purpose, I developed an ImageJ macro Cell Colony Edge and a CellProfiler Pipeline Cell Colony Counting, and compared them to other open-source digital methods and manual counts. The ImageJ macro Cell Colony Edge is valuable in counting cells and colonies, and measuring their area, volume, morphology, and intensity. In this study, I demonstrate that Cell Colony Edge is superior to other open-source methods, in speed, accuracy and applicability to diverse cellular assays. It can fulfill the need to automate colony/cell counting in high-throughput screens, colony forming assays, and cellular assays. PMID:26848849
Image-based red cell counting for wild animals blood.
Mauricio, Claudio R M; Schneider, Fabio K; Dos Santos, Leonilda Correia
2010-01-01
An image-based red blood cell (RBC) automatic counting system is presented for wild animals blood analysis. Images with 2048×1536-pixel resolution acquired on an optical microscope using Neubauer chambers are used to evaluate RBC counting for three animal species (Leopardus pardalis, Cebus apella and Nasua nasua) and the error found using the proposed method is similar to that obtained for inter observer visual counting method, i.e., around 10%. Smaller errors (e.g., 3%) can be obtained in regions with less grid artifacts. These promising results allow the use of the proposed method either as a complete automatic counting tool in laboratories for wild animal's blood analysis or as a first counting stage in a semi-automatic counting tool.
The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures
NASA Astrophysics Data System (ADS)
Stephenson, W. Kirk
2009-08-01
A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes.
Point-by-point compositional analysis for atom probe tomography.
Stephenson, Leigh T; Ceguerra, Anna V; Li, Tong; Rojhirunsakool, Tanaporn; Nag, Soumya; Banerjee, Rajarshi; Cairney, Julie M; Ringer, Simon P
2014-01-01
This new alternate approach to data processing for analyses that traditionally employed grid-based counting methods is necessary because it removes a user-imposed coordinate system that not only limits an analysis but also may introduce errors. We have modified the widely used "binomial" analysis for APT data by replacing grid-based counting with coordinate-independent nearest neighbour identification, improving the measurements and the statistics obtained, allowing quantitative analysis of smaller datasets, and datasets from non-dilute solid solutions. It also allows better visualisation of compositional fluctuations in the data. Our modifications include:.•using spherical k-atom blocks identified by each detected atom's first k nearest neighbours.•3D data visualisation of block composition and nearest neighbour anisotropy.•using z-statistics to directly compare experimental and expected composition curves. Similar modifications may be made to other grid-based counting analyses (contingency table, Langer-Bar-on-Miller, sinusoidal model) and could be instrumental in developing novel data visualisation options.
Diffusion processes in tumors: A nuclear medicine approach
DOE Office of Scientific and Technical Information (OSTI.GOV)
Amaya, Helman, E-mail: haamayae@unal.edu.co
The number of counts used in nuclear medicine imaging techniques, only provides physical information about the desintegration of the nucleus present in the the radiotracer molecules that were uptaken in a particular anatomical region, but that information is not a real metabolic information. For this reason a mathematical method was used to find a correlation between number of counts and {sup 18}F-FDG mass concentration. This correlation allows a better interpretation of the results obtained in the study of diffusive processes in an agar phantom, and based on it, an image from the PETCETIX DICOM sample image set from OsiriX-viewer softwaremore » was processed. PET-CT gradient magnitude and Laplacian images could show direct information on diffusive processes for radiopharmaceuticals that enter into the cells by simple diffusion. In the case of the radiopharmaceutical {sup 18}F-FDG is necessary to include pharmacokinetic models, to make a correct interpretation of the gradient magnitude and Laplacian of counts images.« less
17 CFR 275.203(b)(3)-2 - Methods for counting clients in certain private funds.
Code of Federal Regulations, 2010 CFR
2010-04-01
... 17 Commodity and Securities Exchanges 3 2010-04-01 2010-04-01 false Methods for counting clients....203(b)(3)-2 Methods for counting clients in certain private funds. (a) For purposes of section 203(b)(3) of the Act (15 U.S.C. 80b-3(b)(3)), you must count as clients the shareholders, limited partners...
Platelet counting using the Coulter electronic counter
Eggleton, M. J.; Sharp, A. A.
1963-01-01
A method for counting platelets in dilutions of platelet-rich plasm using the Coulter electronic counter is described.1 The results obtained show that such platelet counts are at least as accurate as the best methods of visual counting. The various technical difficulties encountered are discussed. PMID:16811002
Liu, Yan; Li, Xiaohong; Johnson, Margaret; Smith, Collette; Kamarulzaman, Adeeba bte; Montaner, Julio; Mounzer, Karam; Saag, Michael; Cahn, Pedro; Cesar, Carina; Krolewiecki, Alejandro; Sanne, Ian; Montaner, Luis J.
2012-01-01
Background Global programs of anti-HIV treatment depend on sustained laboratory capacity to assess treatment initiation thresholds and treatment response over time. Currently, there is no valid alternative to CD4 count testing for monitoring immunologic responses to treatment, but laboratory cost and capacity limit access to CD4 testing in resource-constrained settings. Thus, methods to prioritize patients for CD4 count testing could improve treatment monitoring by optimizing resource allocation. Methods and Findings Using a prospective cohort of HIV-infected patients (n = 1,956) monitored upon antiretroviral therapy initiation in seven clinical sites with distinct geographical and socio-economic settings, we retrospectively apply a novel prediction-based classification (PBC) modeling method. The model uses repeatedly measured biomarkers (white blood cell count and lymphocyte percent) to predict CD4+ T cell outcome through first-stage modeling and subsequent classification based on clinically relevant thresholds (CD4+ T cell count of 200 or 350 cells/µl). The algorithm correctly classified 90% (cross-validation estimate = 91.5%, standard deviation [SD] = 4.5%) of CD4 count measurements <200 cells/µl in the first year of follow-up; if laboratory testing is applied only to patients predicted to be below the 200-cells/µl threshold, we estimate a potential savings of 54.3% (SD = 4.2%) in CD4 testing capacity. A capacity savings of 34% (SD = 3.9%) is predicted using a CD4 threshold of 350 cells/µl. Similar results were obtained over the 3 y of follow-up available (n = 619). Limitations include a need for future economic healthcare outcome analysis, a need for assessment of extensibility beyond the 3-y observation time, and the need to assign a false positive threshold. Conclusions Our results support the use of PBC modeling as a triage point at the laboratory, lessening the need for laboratory-based CD4+ T cell count testing; implementation of this tool could help optimize the use of laboratory resources, directing CD4 testing towards higher-risk patients. However, further prospective studies and economic analyses are needed to demonstrate that the PBC model can be effectively applied in clinical settings. Please see later in the article for the Editors' Summary PMID:22529752
Correlations between metabolic syndrome, serologic factors, and gallstones
Sang, Jae Hong; Ki, Nam Kyun; Cho, Jae Hwan; Ahn, Jae Ouk; Sunwoo, Jae Gun
2016-01-01
[Purpose] This study investigated the serologic factors associated with metabolic syndrome and gallstones. [Subjects and Methods] The study evaluated subjects who visited a health promotion center in Seoul from March 2, 2013 to February 28, 2014, and had undergone abdominal ultrasonography. Height, weight, and blood pressure were measured. Blood sampling was performed for high-density lipoprotein cholesterol, triglyceride, fasting blood glucose, total bilirubin, direct bilirubin, indirect bilirubin, aspartate aminotransferase, alanine aminotransferase, alkaline phosphatase, uric acid, total cholesterol, low-density lipoprotein cholesterol, thyroid stimulating hormone, and red and white blood cell counts. We conducted logistic regression analysis to assess the risk factors associated with metabolic syndrome. [Results] The risk factors for metabolic syndrome in men, in order of decreasing weight, were red blood cell count, body mass index, maximum size of gallstones, white blood cell count, waist circumference, and uric acid level. The factors in women, in order of decreasing weight, were red blood cell count, presence/absence of gallstones, uric acid level, body mass index, fasting blood glucose, and waist circumference. [Conclusion] Most serum biochemical factors and gallstone occurrence could be used to indicate the presence or absence of metabolic syndrome, independent of gender. PMID:27630427
Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies.
Petibon, Yoann; Rakvongthai, Yothin; El Fakhri, Georges; Ouyang, Jinsong
2017-05-07
Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18 F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans-each containing 1/8th of the total number of events-were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18 F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted least-square fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori (MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed pre-conditioner. The performance of the direct method was evaluated by comparing voxel- and segment-wise estimates of [Formula: see text], the tracer transport rate (ml · min -1 · ml -1 ), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced [Formula: see text] maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSL-MAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced [Formula: see text] estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance.
Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in-vivo studies
Petibon, Yoann; Rakvongthai, Yothin; Fakhri, Georges El; Ouyang, Jinsong
2017-01-01
Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves -TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in-vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans - each containing 1/8th of the total number of events - were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard Ordered Subset Expectation Maximization (OSEM) reconstruction algorithm on one side, and the One-Step Late Maximum a Posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted least-square fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori (MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed pre-conditioner. The performance of the direct method was evaluated by comparing voxel- and segment-wise estimates of K1, the tracer transport rate (mL.min−1.mL−1), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced K1 maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSL-MAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced K1 estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in-vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance. PMID:28379843
Direct parametric reconstruction in dynamic PET myocardial perfusion imaging: in vivo studies
NASA Astrophysics Data System (ADS)
Petibon, Yoann; Rakvongthai, Yothin; El Fakhri, Georges; Ouyang, Jinsong
2017-05-01
Dynamic PET myocardial perfusion imaging (MPI) used in conjunction with tracer kinetic modeling enables the quantification of absolute myocardial blood flow (MBF). However, MBF maps computed using the traditional indirect method (i.e. post-reconstruction voxel-wise fitting of kinetic model to PET time-activity-curves-TACs) suffer from poor signal-to-noise ratio (SNR). Direct reconstruction of kinetic parameters from raw PET projection data has been shown to offer parametric images with higher SNR compared to the indirect method. The aim of this study was to extend and evaluate the performance of a direct parametric reconstruction method using in vivo dynamic PET MPI data for the purpose of quantifying MBF. Dynamic PET MPI studies were performed on two healthy pigs using a Siemens Biograph mMR scanner. List-mode PET data for each animal were acquired following a bolus injection of ~7-8 mCi of 18F-flurpiridaz, a myocardial perfusion agent. Fully-3D dynamic PET sinograms were obtained by sorting the coincidence events into 16 temporal frames covering ~5 min after radiotracer administration. Additionally, eight independent noise realizations of both scans—each containing 1/8th of the total number of events—were generated from the original list-mode data. Dynamic sinograms were then used to compute parametric maps using the conventional indirect method and the proposed direct method. For both methods, a one-tissue compartment model accounting for spillover from the left and right ventricle blood-pools was used to describe the kinetics of 18F-flurpiridaz. An image-derived arterial input function obtained from a TAC taken in the left ventricle cavity was used for tracer kinetic analysis. For the indirect method, frame-by-frame images were estimated using two fully-3D reconstruction techniques: the standard ordered subset expectation maximization (OSEM) reconstruction algorithm on one side, and the one-step late maximum a posteriori (OSL-MAP) algorithm on the other side, which incorporates a quadratic penalty function. The parametric images were then calculated using voxel-wise weighted least-square fitting of the reconstructed myocardial PET TACs. For the direct method, parametric images were estimated directly from the dynamic PET sinograms using a maximum a posteriori (MAP) parametric reconstruction algorithm which optimizes an objective function comprised of the Poisson log-likelihood term, the kinetic model and a quadratic penalty function. Maximization of the objective function with respect to each set of parameters was achieved using a preconditioned conjugate gradient algorithm with a specifically developed pre-conditioner. The performance of the direct method was evaluated by comparing voxel- and segment-wise estimates of {{K}1} , the tracer transport rate (ml · min-1 · ml-1), to those obtained using the indirect method applied to both OSEM and OSL-MAP dynamic reconstructions. The proposed direct reconstruction method produced {{K}1} maps with visibly lower noise than the indirect method based on OSEM and OSL-MAP reconstructions. At normal count levels, the direct method was shown to outperform the indirect method based on OSL-MAP in the sense that at matched level of bias, reduced regional noise levels were obtained. At lower count levels, the direct method produced {{K}1} estimates with significantly lower standard deviation across noise realizations than the indirect method based on OSL-MAP at matched bias level. In all cases, the direct method yielded lower noise and standard deviation than the indirect method based on OSEM. Overall, the proposed direct reconstruction offered a better bias-variance tradeoff than the indirect method applied to either OSEM and OSL-MAP. Direct parametric reconstruction as applied to in vivo dynamic PET MPI data is therefore a promising method for producing MBF maps with lower variance.
Hematologic reference intervals and age effect in European Strigiformes.
Agusti Montolio, Susana; Molina López, Rafael; Cray, Carolyn; Lavín González, Santiago; Nicolás Francisco, Olga; Marco Sánchez, Ignasi; Casas-Díaz, Encarna; Cuenca Valera, Rafaela
2017-09-01
The clinical importance of hematologic testing in avian veterinary medicine is reflected in the increasing number of studies for the establishment of hematologic RIs of Strigiformes and other species. Age is an important physiologic factor in birds and the effect on hematology variable should be understood. The objective of this study was to determine baseline data of hematologic variables in 5 species of Iberian Strigiformes in different age classes. Nocturnal birds of prey were sampled at Wildlife Health Centers. Packed cell volume was determined by the microhematocrit centrifugation method, and RBC and WBC counts were determined using the direct hemocytometer count method with Natt and Herrick solution. Hemoglobin concentration was measured spectrophotometrically. The MCV, MCHC, and MHC were calculated using the standard formulas. The differential WBC count was performed by the routine microscopic evaluation of 200 cells on a blood smear manually stained with Wright stain. Thrombocyte blood count estimate was obtained from the blood film. No differences were observed between juveniles and adults for any variable evaluated in Tawny owl, Little owl, Scops owl, Long-eared owl, and Barn owl. In addition, PCV, RBC, and HGB of chicks were statistically significantly lower than in juveniles and adults, and total WBC was significantly higher in Tawny owl, Little owl, Scops owl, and Long-eared owl. Our findings provide evidence that laboratory data from chicks of Strigiformes are different compared to juveniles and adults; therefore, separate RIs were defined. © 2017 American Society for Veterinary Clinical Pathology.
Rapid in situ assessment of physiological activities in bacterial biofilms using fluorescent probes
NASA Technical Reports Server (NTRS)
Yu, F. P.; McFeters, G. A.
1994-01-01
Two rapid in situ enumeration methods using fluorescent probes were used to assess the physiological activities of Klebsiella pneumoniae biofilms on stainless steel. Fluorescent dyes, 5-cyano-2,3-ditolyl tetrazolium chloride (CTC) and rhodamine 123 (Rh 123), were chosen to perform this study. CTC is a soluble redox indicator which can be reduced by respiring bacteria to fluorescent CTC-formazan crystals. Rh 123 is incorporated into bacteria with respect to cellular proton motive force. The intracellular accumulation of these fluorescent dyes can be determined using epifluorescence microscopy. The results obtained with these two fluorescent probes in situ were compared to the plate count (PC) and in situ direct viable count (DVC) methods. Viable cell densities within biofilms determined by the three in situ methods were comparable and always showed approximately 2-fold higher values than those obtained with the PC method. As an additional advantage, the results were observed after 2 h, which was shorter than the 4 h incubation time required for the DVC method and 24 h for colony formation. The results indicate that staining with CTC and Rh 123 provides rapid information regarding cell numbers and physiological activities of bacteria within biofilms.
Texture analysis with statistical methods for wheat ear extraction
NASA Astrophysics Data System (ADS)
Bakhouche, M.; Cointault, F.; Gouton, P.
2007-01-01
In agronomic domain, the simplification of crop counting, necessary for yield prediction and agronomic studies, is an important project for technical institutes such as Arvalis. Although the main objective of our global project is to conceive a mobile robot for natural image acquisition directly in a field, Arvalis has proposed us first to detect by image processing the number of wheat ears in images before to count them, which will allow to obtain the first component of the yield. In this paper we compare different texture image segmentation techniques based on feature extraction by first and higher order statistical methods which have been applied on our images. The extracted features are used for unsupervised pixel classification to obtain the different classes in the image. So, the K-means algorithm is implemented before the choice of a threshold to highlight the ears. Three methods have been tested in this feasibility study with very average error of 6%. Although the evaluation of the quality of the detection is visually done, automatic evaluation algorithms are currently implementing. Moreover, other statistical methods of higher order will be implemented in the future jointly with methods based on spatio-frequential transforms and specific filtering.
ASSESSMENT OF INTAKE ACCORDING TO IDEAS GUIDANCE: CASE STUDY.
Bitar, A; Maghrabi, M
2018-04-01
Estimation of radiation intake and internal dose can be carried out through direct or indirect measurements during routine or special monitoring program. In case of Iodine-131 contamination, direct measurements, such as thyroid counting, are fast and efficient to give quick results. Generally, the calculation method implements suitable values for known parameters whereas default values are used if no information is available. However, in view to avoid significant discrepancies, IDEAS guidelines put in route a comprehensive method to evaluate the monitoring data for one and different types of monitoring. This article deals with a case of internal contamination of a worker who inhaled aerosols containing 131I during the production of radiopharmaceuticals. The interpretation of data obtained was done by following IDEAS guidelines.
ERIC Educational Resources Information Center
Madsen, Mark S.
2010-01-01
The purpose of this research has been to generate learning environments that surrounded second and third grade students with bi-directional counting experiences, leading them to discover and come to an understanding of opposite numbers. While engaged in games and bi-directional activities, these young students eagerly counted, by jumping frogs…
The clinical significance of platelet counts in the first 24 hours after severe injury.
Stansbury, Lynn G; Hess, Aaron S; Thompson, Kwaku; Kramer, Betsy; Scalea, Thomas M; Hess, John R
2013-04-01
Admission platelet (PLT) counts are known to be associated with all-cause mortality for seriously injured patients admitted to a trauma center. The course of subsequent PLT counts, their implications, and the effects of PLT therapy are less well known. Trauma center patients who were directly admitted from the scene of injury, received 1 or more units of uncrossmatched red blood cells in the first hour of care, survived for at least 15 minutes, and had a PLT count measured in the first hour were analyzed for the association of their admission and subsequent PLT counts in the first 24 hours with injury severity and hemorrhagic and central nervous system (CNS) causes of in-hospital mortality. Over an 8.25-year period, 1292 of 45,849 direct trauma admissions met entry criteria. Admission PLT counts averaged 228×10(9) ±90×10(9) /L and decreased by 104×10(9) /L by the second hour and 1×10(9) /L each hour thereafter. The admission count was not related to time to admission. Each 1-point increase in the injury severity score was associated with a 1×10(9) /L decrease in the PLT count at all times in the first 24 hours of care. Admission PLT counts were strongly associated with hemorrhagic and CNS injury mortality and subsequent PLT counts. Effects of PLT therapy could not be ascertained. Admission PLT counts in critically injured trauma patients are usually normal, decreasing after admission. Low PLT counts at admission and during the course of trauma care are strongly associated with mortality. © 2012 American Association of Blood Banks.
Farnsworth, G.L.; Nichols, J.D.; Sauer, J.R.; Fancy, S.G.; Pollock, K.H.; Shriner, S.A.; Simons, T.R.; Ralph, C. John; Rich, Terrell D.
2005-01-01
Point counts are a standard sampling procedure for many bird species, but lingering concerns still exist about the quality of information produced from the method. It is well known that variation in observer ability and environmental conditions can influence the detection probability of birds in point counts, but many biologists have been reluctant to abandon point counts in favor of more intensive approaches to counting. However, over the past few years a variety of statistical and methodological developments have begun to provide practical ways of overcoming some of the problems with point counts. We describe some of these approaches, and show how they can be integrated into standard point count protocols to greatly enhance the quality of the information. Several tools now exist for estimation of detection probability of birds during counts, including distance sampling, double observer methods, time-depletion (removal) methods, and hybrid methods that combine these approaches. Many counts are conducted in habitats that make auditory detection of birds much more likely than visual detection. As a framework for understanding detection probability during such counts, we propose separating two components of the probability a bird is detected during a count into (1) the probability a bird vocalizes during the count and (2) the probability this vocalization is detected by an observer. In addition, we propose that some measure of the area sampled during a count is necessary for valid inferences about bird populations. This can be done by employing fixed-radius counts or more sophisticated distance-sampling models. We recommend any studies employing point counts be designed to estimate detection probability and to include a measure of the area sampled.
The Box-and-Dot Method: A Simple Strategy for Counting Significant Figures
ERIC Educational Resources Information Center
Stephenson, W. Kirk
2009-01-01
A visual method for counting significant digits is presented. This easy-to-learn (and easy-to-teach) method, designated the box-and-dot method, uses the device of "boxing" significant figures based on two simple rules, then counting the number of digits in the boxes. (Contains 4 notes.)
NASA Astrophysics Data System (ADS)
Vachálek, Ján
2011-12-01
The paper compares the abilities of forgetting methods to track time varying parameters of two different simulated models with different types of excitation. The observed parameters in the simulations are the integral sum of the Euclidean norm, deviation of the parameter estimates from their true values and a selected band prediction error count. As supplementary information, we observe the eigenvalues of the covariance matrix. In the paper we used a modified method of Regularized Exponential Forgetting with Alternative Covariance Matrix (REFACM) along with Directional Forgetting (DF) and three standard regularized methods.
HRO: A New Forward-Scatter Observation Method Using a Ham-Band Beacon
NASA Astrophysics Data System (ADS)
Maegawa, K.
1999-02-01
A new forward-scatter meteor observation method has been used since 1996 in Japan. It uses its own 50 W continuous wave beacon with a broad directivity antenna on 53.750 MHz. To compensate for the weak echo power from the beacon, observers use SSB mode receivers and narrow band echo detection methods with Fast Fourier Transform software on personal computers. More than 250000 echoes have been counted per year so far. >From these results, diurnal and seasonal variations have been derived and are presented and discussed here. This method (HRO) will continue to play a leading radio observation role in Japan for the future.
Inter-rater reliability of malaria parasite counts and comparison of methods
2009-01-01
Background The introduction of artemesinin-based treatment for falciparum malaria has led to a shift away from symptom-based diagnosis. Diagnosis may be achieved by using rapid non-microscopic diagnostic tests (RDTs), of which there are many available. Light microscopy, however, has a central role in parasite identification and quantification and remains the main method of parasite-based diagnosis in clinic and hospital settings and is necessary for monitoring the accuracy of RDTs. The World Health Organization has prepared a proficiency testing panel containing a range of malaria-positive blood samples of known parasitaemia, to be used for the assessment of commercially available malaria RDTs. Different blood film and counting methods may be used for this purpose, which raises questions regarding accuracy and reproducibility. A comparison was made of the established methods for parasitaemia estimation to determine which would give the least inter-rater and inter-method variation Methods Experienced malaria microscopists counted asexual parasitaemia on different slides using three methods; the thin film method using the total erythrocyte count, the thick film method using the total white cell count and the Earle and Perez method. All the slides were stained using Giemsa pH 7.2. Analysis of variance (ANOVA) models were used to find the inter-rater reliability for the different methods. The paired t-test was used to assess any systematic bias between the two methods, and a regression analysis was used to see if there was a changing bias with parasite count level. Results The thin blood film gave parasite counts around 30% higher than those obtained by the thick film and Earle and Perez methods, but exhibited a loss of sensitivity with low parasitaemia. The thick film and Earle and Perez methods showed little or no bias in counts between the two methods, however, estimated inter-rater reliability was slightly better for the thick film method. Conclusion The thin film method gave results closer to the true parasite count but is not feasible at a parasitaemia below 500 parasites per microlitre. The thick film method was both reproducible and practical for this project. The determination of malarial parasitaemia must be applied by skilled operators using standardized techniques. PMID:19939271
Celler, Anna; Piwowarska-Bilska, Hanna; Shcherbinin, Sergey; Uribe, Carlos; Mikolajczak, Renata; Birkenfeld, Bozena
2014-01-01
Dead-time (DT) effects rarely cause problems in diagnostic single-photon emission computed tomography (SPECT) studies; however, in post-radionuclide-therapy imaging, DT can be substantial. Therefore, corrections may be necessary if quantitative images are used in image-based dosimetry or for evaluation of therapy outcomes. This task is particularly challenging if low-energy collimators are used. Our goal was to design a simple method to determine the dead-time correction factor (DTCF) without the need for phantom experiments and complex calculations. Planar and SPECT/CT scans of a water phantom containing a 70 ml bottle filled with lutetium-177 (Lu) were acquired over 60 days. Two small Lu markers were used in all scans. The DTCF based on the ratio of observed to true count rates measured over the entire spectrum and using photopeak primary photons only was estimated for phantom (DT present) and marker (no DT) scans. In addition, variations in counts in SPECT projections (potentially caused by varying bremsstrahlung and scatter) were investigated. For count rates that were about two-fold higher than typically seen in post-therapy Lu scans, the maximum DTCF reached a level of about 17%. The DTCF values determined directly from the phantom experiments using the total energy spectrum and photopeak counts only were equal to 13 and 16%, respectively. They were closely matched by those from the proposed marker-based method, which uses only two energy windows and measures photopeak primary photons (15-17%). A simple, marker-based method allowing for determination of the DTCF in high-activity Lu imaging studies has been proposed and validated using phantom experiments.
Validation of a quantitative Eimeria spp. PCR for fresh droppings of broiler chickens.
Peek, H W; Ter Veen, C; Dijkman, R; Landman, W J M
2017-12-01
A quantitative Polymerase Chain Reaction (qPCR) for the seven chicken Eimeria spp. was modified and validated for direct use on fresh droppings. The analytical specificity of the qPCR on droppings was 100%. Its analytical sensitivity (non-sporulated oocysts/g droppings) was 41 for E. acervulina, ≤2900 for E. brunetti, 710 for E. praecox, 1500 for E. necatrix, 190 for E. tenella, 640 for E. maxima, and 1100 for E. mitis. Field validation of the qPCR was done using droppings with non-sporulated oocysts from 19 broiler flocks. To reduce the number of qPCR tests five grams of each pooled sample (consisting of ten fresh droppings) per time point were blended into one mixed sample. Comparison of the oocysts per gram (OPG)-counting method with the qPCR using pooled samples (n = 1180) yielded a Pearson's correlation coefficient of 0.78 (95% CI: 0.76-0.80) and a Pearson's correlation coefficient of 0.76 (95% CI: 0.70-0.81) using mixed samples (n = 236). Comparison of the average of the OPG-counts of the five pooled samples with the mixed sample per time point (n = 236) showed a Pearson's correlation coefficient (R) of 0.94 (95% CI: 0.92-0.95) for the OPG-counting method and 0.87 (95% CI: 0.84-0.90) for the qPCR. This indicates that mixed samples are practically equivalent to the mean of five pooled samples. The good correlation between the OPG-counting method and the qPCR was further confirmed by the visual agreement between the total oocyst/g shedding patterns measured with both techniques in the 19 broiler flocks using the mixed samples.
Dynamic pulse difference circuit
Erickson, Gerald L.
1978-01-01
A digital electronic circuit of especial use for subtracting background activity pulses in gamma spectrometry comprises an up-down counter connected to count up with signal-channel pulses and to count down with background-channel pulses. A detector responsive to the count position of the up-down counter provides a signal when the up-down counter has completed one scaling sequence cycle of counts in the up direction. In an alternate embodiment, a detector responsive to the count position of the up-down counter provides a signal upon overflow of the counter.
Evaluation of petrifilm series 2000 as a possible rapid method to count coliforms in foods.
Priego, R; Medina, L M; Jordano, R
2000-08-01
This research note is a preliminary comparison between the Petrifilm 2000 method and a widely used traditional enumeration method (on violet red bile agar); six batches of different foods (egg, frozen green beans, fresh sausage, a bakery product, raw minced meat, and raw milk) were studied. The reliability of the presumptive counts taken at 10, 12, and 14 h of incubation using this method was also verified by comparing the counts with the total confirmed counts at 24 h. In all the batches studied, results obtained with Petrifilm 2000 presented a close correlation to those obtained using violet red bile agar (r = 0.860) and greater sensitivity (93.33% of the samples displayed higher counts on Petrifilm 2000), showing that this method is a reliable and efficient alternative. The count taken at 10-h incubation is of clear interest as an early indicator of results in microbiological food control, since it accounted for 90% of the final count in all the batches analyzed. Counts taken at 12 and 14 h bore a greater similarity to those taken at 24 h. The Petrifilm 2000 method provides results in less than 12 h of incubation, making it a possible rapid method that adapts perfectly to hazard analysis critical control point system by enabling the microbiological quality control of the processing.
Minimum Detectable Activity for Tomographic Gamma Scanning System
DOE Office of Scientific and Technical Information (OSTI.GOV)
Venkataraman, Ram; Smith, Susan; Kirkpatrick, J. M.
2015-01-01
For any radiation measurement system, it is useful to explore and establish the detection limits and a minimum detectable activity (MDA) for the radionuclides of interest, even if the system is to be used at far higher values. The MDA serves as an important figure of merit, and often a system is optimized and configured so that it can meet the MDA requirements of a measurement campaign. The non-destructive assay (NDA) systems based on gamma ray analysis are no exception and well established conventions, such the Currie method, exist for estimating the detection limits and the MDA. However, the Tomographicmore » Gamma Scanning (TGS) technique poses some challenges for the estimation of detection limits and MDAs. The TGS combines high resolution gamma ray spectrometry (HRGS) with low spatial resolution image reconstruction techniques. In non-imaging gamma ray based NDA techniques measured counts in a full energy peak can be used to estimate the activity of a radionuclide, independently of other counting trials. However, in the case of the TGS each “view” is a full spectral grab (each a counting trial), and each scan consists of 150 spectral grabs in the transmission and emission scans per vertical layer of the item. The set of views in a complete scan are then used to solve for the radionuclide activities on a voxel by voxel basis, over 16 layers of a 10x10 voxel grid. Thus, the raw count data are not independent trials any more, but rather constitute input to a matrix solution for the emission image values at the various locations inside the item volume used in the reconstruction. So, the validity of the methods used to estimate MDA for an imaging technique such as TGS warrant a close scrutiny, because the pair-counting concept of Currie is not directly applicable. One can also raise questions as to whether the TGS, along with other image reconstruction techniques which heavily intertwine data, is a suitable method if one expects to measure samples whose activities are at or just above MDA levels. The paper examines methods used to estimate MDAs for a TGS system, and explores possible solutions that can be rigorously defended.« less
... Absolute reticulocyte count Direct or indirect Coombs test Hemoglobin in the urine LDH (level of this enzyme ... of tissue damage) Red blood cell count (RBC), hemoglobin, and hematocrit Serum bilirubin level Serum free hemoglobin ...
Reactivity measurements using the Zolotukhin-Mogilner Method
DOE Office of Scientific and Technical Information (OSTI.GOV)
NONE
2015-07-01
The zero count probability method (also called Zolotukhin-Mogilner Method, after its inventors) is a method for measuring the reactivity in nuclear reactors, being a competitor of the [more well-known in the West] Feynman-alpha Method and the Rossi-alpha Method. The modus operandi of this method is using the detector channels where there was no counting at all in order to calculate reactor parameters. In deep subcriticality few models have been tested and this work tries out the Zolotukhin-Mogilner Method in one of such scenarios: measurements will be made in environments below -3,5 k pcm in the zero-potency water-moderated reactor IPEN/MB-01 whichmore » is fuelled by UO{sub 2} enriched by 4.3%. These extremely low reactivity environments are required because the chance of no counts on the detector must be significant: otherwise, the method would demand a large time of acquisition of data. Besides that, the method is very simple and straightforward. One of the advantages of this method is that it needs very little data reduction, since the essential data is directly given by the measuring apparatus. The detection will be in charge of modern BF{sub 3} detectors. It will be assumed that, in these deep subcritical systems, the function K{sub eff} = f(N-Nkp) has a linear portion in its first part, resulting of the decomposition of it in a Taylor series. The value of alpha is related to the reactivity ρ with linear dependency. The results will be compared with recent studies of the two main methods described above. Presented for the first time in the 60's, this tool has seen little use in the west hemisphere. This work shows its use in the measurements of the nuclear reactor IPEN/MB-01, as well as the code developed for its employment. It will be the first time this method is used in the south hemisphere. (authors)« less
NASA Astrophysics Data System (ADS)
Bolis, A.; Cantwell, C. D.; Moxey, D.; Serson, D.; Sherwin, S. J.
2016-09-01
A hybrid parallelisation technique for distributed memory systems is investigated for a coupled Fourier-spectral/hp element discretisation of domains characterised by geometric homogeneity in one or more directions. The performance of the approach is mathematically modelled in terms of operation count and communication costs for identifying the most efficient parameter choices. The model is calibrated to target a specific hardware platform after which it is shown to accurately predict the performance in the hybrid regime. The method is applied to modelling turbulent flow using the incompressible Navier-Stokes equations in an axisymmetric pipe and square channel. The hybrid method extends the practical limitations of the discretisation, allowing greater parallelism and reduced wall times. Performance is shown to continue to scale when both parallelisation strategies are used.
Sarkar, Sumona; Lund, Steven P; Vyzasatya, Ravi; Vanguri, Padmavathy; Elliott, John T; Plant, Anne L; Lin-Gibson, Sheng
2017-12-01
Cell counting measurements are critical in the research, development and manufacturing of cell-based products, yet determining cell quantity with accuracy and precision remains a challenge. Validating and evaluating a cell counting measurement process can be difficult because of the lack of appropriate reference material. Here we describe an experimental design and statistical analysis approach to evaluate the quality of a cell counting measurement process in the absence of appropriate reference materials or reference methods. The experimental design is based on a dilution series study with replicate samples and observations as well as measurement process controls. The statistical analysis evaluates the precision and proportionality of the cell counting measurement process and can be used to compare the quality of two or more counting methods. As an illustration of this approach, cell counting measurement processes (automated and manual methods) were compared for a human mesenchymal stromal cell (hMSC) preparation. For the hMSC preparation investigated, results indicated that the automated method performed better than the manual counting methods in terms of precision and proportionality. By conducting well controlled dilution series experimental designs coupled with appropriate statistical analysis, quantitative indicators of repeatability and proportionality can be calculated to provide an assessment of cell counting measurement quality. This approach does not rely on the use of a reference material or comparison to "gold standard" methods known to have limited assurance of accuracy and precision. The approach presented here may help the selection, optimization, and/or validation of a cell counting measurement process. Published by Elsevier Inc.
Method and means for measuring the anisotropy of a plasma in a magnetic field
Shohet, J.L.; Greene, D.G.S.
1973-10-23
Anisotropy is measured of a free-free-bremsstrahlungradiation-generating plasma in a magnetic field by collimating the free-free bremsstrahlung radiation in a direction normal to the magnetic field and scattering the collimated free- free bremsstrahlung radiation to resolve the radiation into its vector components in a plane parallel to the electric field of the bremsstrahlung radiation. The scattered vector components are counted at particular energy levels in a direction parallel to the magnetic field and also normal to the magnetic field of the plasma to provide a measure of anisotropy of the plasma. (Official Gazette)
Mueller, Sherry A; Anderson, James E; Kim, Byung R; Ball, James C
2009-04-01
Effective bacterial control in cooling-tower systems requires accurate and timely methods to count bacteria. Plate-count methods are difficult to implement on-site, because they are time- and labor-intensive and require sterile techniques. Several field-applicable methods (dipslides, Petrifilm, and adenosine triphosphate [ATP] bioluminescence) were compared with the plate count for two sample matrices--phosphate-buffered saline solution containing a pure culture of Pseudomonas fluorescens and cooling-tower water containing an undefined mixed bacterial culture. For the pure culture, (1) counts determined on nutrient agar and plate-count agar (PCA) media and expressed as colony-forming units (CFU) per milliliter were equivalent to those on R2A medium (p = 1.0 and p = 1.0, respectively); (2) Petrifilm counts were not significantly different from R2A plate counts (p = 0.99); (3) the dipslide counts were up to 2 log units higher than R2A plate counts, but this discrepancy was not statistically significant (p = 0.06); and (4) a discernable correlation (r2 = 0.67) existed between ATP readings and plate counts. For cooling-tower water samples (n = 62), (1) bacterial counts using R2A medium were higher (but not significant; p = 0.63) than nutrient agar and significantly higher than tryptone-glucose yeast extract (TGE; p = 0.03) and PCA (p < 0.001); (2) Petrifilm counts were significantly lower than nutrient agar or R2A (p = 0.02 and p < 0.001, respectively), but not statistically different from TGE, PCA, and dipslides (p = 0.55, p = 0.69, and p = 0.91, respectively); (3) the dipslide method yielded bacteria counts 1 to 3 log units lower than nutrient agar and R2A (p < 0.001), but was not significantly different from Petrifilm (p = 0.91), PCA (p = 1.00) or TGE (p = 0.07); (4) the differences between dipslides and the other methods became greater with a 6-day incubation time; and (5) the correlation between ATP readings and plate counts varied from system to system, was poor (r2 values ranged from < 0.01 to 0.47), and the ATP method was not sufficiently sensitive to measure counts below approximately 10(4) CFU/mL.
Validation of an automated colony counting system for group A Streptococcus.
Frost, H R; Tsoi, S K; Baker, C A; Laho, D; Sanderson-Smith, M L; Steer, A C; Smeesters, P R
2016-02-08
The practice of counting bacterial colony forming units on agar plates has long been used as a method to estimate the concentration of live bacteria in culture. However, due to the laborious and potentially error prone nature of this measurement technique, an alternative method is desirable. Recent technologic advancements have facilitated the development of automated colony counting systems, which reduce errors introduced during the manual counting process and recording of information. An additional benefit is the significant reduction in time taken to analyse colony counting data. Whilst automated counting procedures have been validated for a number of microorganisms, the process has not been successful for all bacteria due to the requirement for a relatively high contrast between bacterial colonies and growth medium. The purpose of this study was to validate an automated counting system for use with group A Streptococcus (GAS). Twenty-one different GAS strains, representative of major emm-types, were selected for assessment. In order to introduce the required contrast for automated counting, 2,3,5-triphenyl-2H-tetrazolium chloride (TTC) dye was added to Todd-Hewitt broth with yeast extract (THY) agar. Growth on THY agar with TTC was compared with growth on blood agar and THY agar to ensure the dye was not detrimental to bacterial growth. Automated colony counts using a ProtoCOL 3 instrument were compared with manual counting to confirm accuracy over the stages of the growth cycle (latent, mid-log and stationary phases) and in a number of different assays. The average percentage differences between plating and counting methods were analysed using the Bland-Altman method. A percentage difference of ±10 % was determined as the cut-off for a critical difference between plating and counting methods. All strains measured had an average difference of less than 10 % when plated on THY agar with TTC. This consistency was also observed over all phases of the growth cycle and when plated in blood following bactericidal assays. Agreement between these methods suggest the use of an automated colony counting technique for GAS will significantly reduce time spent counting bacteria to enable a more efficient and accurate measurement of bacteria concentration in culture.
29 CFR 2590.701-5 - Evidence of creditable coverage.
Code of Federal Regulations, 2010 CFR
2010-07-01
... under paragraph (b)(2) of this section (relating to the alternative method of counting creditable... benefits described in § 2590.701-4(c) (relating to the alternative method of counting creditable coverage... using the alternative method of counting creditable coverage—(1) In general. After an individual...
NASA Astrophysics Data System (ADS)
Grams, Guilherme; Schuch, Nelson Jorge; Braga, Carlos Roberto; Purushottam Kane, Rajaram; Echer, Ezequiel; Ronan Coelho Stekel, Tardelli
Cosmic ray are charged particles, at the most time protons, that reach the earth's magne-tosphere from interplanetary space with velocities greater than the solar wind. When these impinge the atmosphere, they interact with atmosphere constituents and decay into sub-particles forming an atmospheric shower. The muons are the sub-particles which normally maintain the originated direction of the primary cosmic ray. A multi-directional muon detec-tor (MMD) was installed in 2001 and upgraded in 2005, through an international cooperation between Brazil, Japan and USA, and operated since then at the Southern Space Observatory -SSO/CRS/CCR/INPE -MCT, (29,4° S, 53,8° W, 480m a.s.l.), São Martinho da Serra, RS, a Brazil. The main objetive of this work is to present a statistical analysis of the intensity of muons, with energy between 50 and 170 GeV, in differents directions, measured by the SSO's multi-directional muon detector. The analysis was performed with data from 2006 and 2007 collected by the SSO's MMD. The MMD consists of two layers of 4x7 detectors with a total observation area of 28 m2 . The counting of muons in each directional channel is made by a coincidence of pulses pair, one from a detector in the upper layer and the other from a detector in the lower layer. The SSO's MMD is equipped with 119 directional channels for muon count rate measurement and is capable of detecting muons incident with zenithal angle between 0° and 75,53° . A statistical analysis was made with the MMD muon count rate for all the di-rectional channels. The average and the standard deviation of the muon count rate in each directional component were calculated. The results show lower cont rate for the channels with larger zenith, and higher cont rate with smaller zenith, as expected from the production and propagation of muons in the atmosphere. It is also possible to identify the Stormer cone. The SSO's MMD is also a detector component of the Global Muon Detector Network (GMDN), which has been developed in an international collaboration lead by Shinshu University, Japan.
NASA Technical Reports Server (NTRS)
Kraft, Ralph P.; Burrows, David N.; Nousek, John A.
1991-01-01
Two different methods, classical and Bayesian, for determining confidence intervals involving Poisson-distributed data are compared. Particular consideration is given to cases where the number of counts observed is small and is comparable to the mean number of background counts. Reasons for preferring the Bayesian over the classical method are given. Tables of confidence limits calculated by the Bayesian method are provided for quick reference.
Perfect count: a novel approach for the single platform enumeration of absolute CD4+ T-lymphocytes.
Storie, Ian; Sawle, Alex; Goodfellow, Karen; Whitby, Liam; Granger, Vivian; Ward, Rosalie Y; Peel, Janet; Smart, Theresa; Reilly, John T; Barnett, David
2004-01-01
The derivation of reliable CD4(+) T lymphocyte counts is vital for the monitoring of disease progression and therapeutic effectiveness in HIV(+) individuals. Flow cytometry has emerged as the method of choice for CD4(+) T lymphocyte enumeration, with single-platform technology, coupled with reference counting beads, fast becoming the "gold standard." However, although single-platform, bead-based, sample acquisition requires the ratio of beads to cells to remain unchanged, there is no available method, until recently, to monitor this. Perfect Count beads have been developed to address this issue and to incorporate two bead populations, with different densities, to allow the detection of inadequate mixing. Comparison of the relative proportions of both beads with the manufacture's defined limits enables an internal QC check during sample acquisition. In this study, we have compared CD4(+) T lymphocyte counts, obtained from 104 HIV(+) patients, using TruCount beads with MultiSet software (defined as the predicated method) and the new Perfect Count beads, incorporating an in house sequential gating strategy. We have demonstrated an excellent degree of correlation between the predicate method and the Perfect Count system (r(2) = 0.9955; Bland Altman bias +27 CD4(+) T lymphocytes/microl). The Perfect Count system is a robust method for performing single platform absolute counts and has the added advantage of having internal QC checks. Such an approach enables the operator to identify potential problems during sample preparation, acquisition and analysis. Copyright 2003 Wiley-Liss, Inc.
Quantitative comparison of the in situ microbial communities in different biomes
DOE Office of Scientific and Technical Information (OSTI.GOV)
White, D.C.; Ringelberg, D.B.; Palmer, R.J.
1995-12-31
A system to define microbial communities in different biomes requires the application of non-traditional methodology. Classical microbiological methods have severe limitations for the analysis of environmental samples. Pure-culture isolation, biochemical testing, and/or enumeration by direct microscopic counting are not well suited for the estimation of total biomass or the assessment of community composition within environmental samples. Such methods provide little insight into the in situ phenotypic activity of the extant microbiota since these techniques are dependent on microbial growth and thus select against many environmental microorganisms which are non- culturable under a wide range of conditions. It has been repeatedlymore » documented in the literature that viable counts or direct counts of bacteria attached to sediment grains are difficult to quantitative and may grossly underestimate the extent of the existing community. The traditional tests provide little indication of the in situ nutritional status or for evidence of toxicity within the microbial community. A more recent development (MIDI Microbial Identification System), measure free and ester-linked fatty acids from isolated microorganisms. Bacterial isolates are identified by comparing their fatty acid profiles to the MIKI database which contains over 8000 entries. The application of the MIKI system to the analysis of environmental samples however, has significant drawbacks. The MIDI system was developed to identify clinical microorganisms and requires their isolation and culture on trypticase soy agar at 27{degrees}C. Since many isolates are unable to grow at these restrictive growth conditions, the system does not lend itself to identification of some environmental organisms. A more applicable methodology for environmental microbial analysis is based on the liquid extrication and separation of microbial lipids from environmental samples, followed by quantitative analysis using gas chromatography/« less
Wolffs, Petra; Norling, Börje; Rådström, Peter
2005-03-01
Real-time PCR technology is increasingly used for detection and quantification of pathogens in food samples. A main disadvantage of nucleic acid detection is the inability to distinguish between signals originating from viable cells and DNA released from dead cells. In order to gain knowledge concerning risks of false-positive results due to detection of DNA originating from dead cells, quantitative PCR (qPCR) was used to investigate the degradation kinetics of free DNA in four types of meat samples. Results showed that the fastest degradation rate was observed (1 log unit per 0.5 h) in chicken homogenate, whereas the slowest rate was observed in pork rinse (1 log unit per 120.5 h). Overall results indicated that degradation occurred faster in chicken samples than in pork samples and faster at higher temperatures. Based on these results, it was concluded that, especially in pork samples, there is a risk of false-positive PCR results. This was confirmed in a quantitative study on cell death and signal persistence over a period of 28 days, employing three different methods, i.e. viable counts, direct qPCR, and finally floatation, a recently developed discontinuous density centrifugation method, followed by qPCR. Results showed that direct qPCR resulted in an overestimation of up to 10 times of the amount of cells in the samples compared to viable counts, due to detection of DNA from dead cells. However, after using floatation prior to qPCR, results resembled the viable count data. This indicates that by using of floatation as a sample treatment step prior to qPCR, the risk of false-positive PCR results due to detection of dead cells, can be minimized.
NASA Astrophysics Data System (ADS)
Zhou, Ping; Zev Rymer, William
2004-12-01
The number of motor unit action potentials (MUAPs) appearing in the surface electromyogram (EMG) signal is directly related to motor unit recruitment and firing rates and therefore offers potentially valuable information about the level of activation of the motoneuron pool. In this paper, based on morphological features of the surface MUAPs, we try to estimate the number of MUAPs present in the surface EMG by counting the negative peaks in the signal. Several signal processing procedures are applied to the surface EMG to facilitate this peak counting process. The MUAP number estimation performance by this approach is first illustrated using the surface EMG simulations. Then, by evaluating the peak counting results from the EMG records detected by a very selective surface electrode, at different contraction levels of the first dorsal interosseous (FDI) muscles, the utility and limitations of such direct peak counts for MUAP number estimation in surface EMG are further explored.
Preisser, John S; Long, D Leann; Stamm, John W
2017-01-01
Marginalized zero-inflated count regression models have recently been introduced for the statistical analysis of dental caries indices and other zero-inflated count data as alternatives to traditional zero-inflated and hurdle models. Unlike the standard approaches, the marginalized models directly estimate overall exposure or treatment effects by relating covariates to the marginal mean count. This article discusses model interpretation and model class choice according to the research question being addressed in caries research. Two data sets, one consisting of fictional dmft counts in 2 groups and the other on DMFS among schoolchildren from a randomized clinical trial comparing 3 toothpaste formulations to prevent incident dental caries, are analyzed with negative binomial hurdle, zero-inflated negative binomial, and marginalized zero-inflated negative binomial models. In the first example, estimates of treatment effects vary according to the type of incidence rate ratio (IRR) estimated by the model. Estimates of IRRs in the analysis of the randomized clinical trial were similar despite their distinctive interpretations. The choice of statistical model class should match the study's purpose, while accounting for the broad decline in children's caries experience, such that dmft and DMFS indices more frequently generate zero counts. Marginalized (marginal mean) models for zero-inflated count data should be considered for direct assessment of exposure effects on the marginal mean dental caries count in the presence of high frequencies of zero counts. © 2017 S. Karger AG, Basel.
Preisser, John S.; Long, D. Leann; Stamm, John W.
2017-01-01
Marginalized zero-inflated count regression models have recently been introduced for the statistical analysis of dental caries indices and other zero-inflated count data as alternatives to traditional zero-inflated and hurdle models. Unlike the standard approaches, the marginalized models directly estimate overall exposure or treatment effects by relating covariates to the marginal mean count. This article discusses model interpretation and model class choice according to the research question being addressed in caries research. Two datasets, one consisting of fictional dmft counts in two groups and the other on DMFS among schoolchildren from a randomized clinical trial (RCT) comparing three toothpaste formulations to prevent incident dental caries, are analysed with negative binomial hurdle (NBH), zero-inflated negative binomial (ZINB), and marginalized zero-inflated negative binomial (MZINB) models. In the first example, estimates of treatment effects vary according to the type of incidence rate ratio (IRR) estimated by the model. Estimates of IRRs in the analysis of the RCT were similar despite their distinctive interpretations. Choice of statistical model class should match the study’s purpose, while accounting for the broad decline in children’s caries experience, such that dmft and DMFS indices more frequently generate zero counts. Marginalized (marginal mean) models for zero-inflated count data should be considered for direct assessment of exposure effects on the marginal mean dental caries count in the presence of high frequencies of zero counts. PMID:28291962
Automatic, time-interval traffic counts for recreation area management planning
D. L. Erickson; C. J. Liu; H. K. Cordell
1980-01-01
Automatic, time-interval recorders were used to count directional vehicular traffic on a multiple entry/exit road network in the Red River Gorge Geological Area, Daniel Boone National Forest. Hourly counts of entering and exiting traffic differed according to recorder location, but an aggregated distribution showed a delayed peak in exiting traffic thought to be...
Habash, Marc; Johns, Robert
2009-10-01
This study compared an automated Escherichia coli and coliform detection system with the membrane filtration direct count technique for water testing. The automated instrument performed equal to or better than the membrane filtration test in analyzing E. coli-spiked samples and blind samples with interference from Proteus vulgaris or Aeromonas hydrophila.
Xu, Xiaoli; Peng, Cheng; Wang, Xiaofu; Chen, Xiaoyun; Wang, Qiang; Xu, Junfeng
2016-12-01
This study evaluated the applicability of droplet digital PCR (ddPCR) as a tool for maize zygosity determination using quantitative real-time PCR (qPCR) as a reference technology. Quantitative real-time PCR is commonly used to determine transgene copy number or GMO zygosity characterization. However, its effectiveness is based on identical reaction efficiencies for the transgene and the endogenous reference gene. Additionally, a calibrator sample should be utilized for accuracy. Droplet digital PCR is a DNA molecule counting technique that directly counts the absolute number of target and reference DNA molecules in a sample, independent of assay efficiency or external calibrators. The zygosity of the transgene can be easily determined using the ratio of the quantity of the target gene to the reference single copy endogenous gene. In this study, both the qPCR and ddPCR methods were used to determine insect-resistant transgenic maize IE034 zygosity. Both methods performed well, but the ddPCR method was more convenient because of its absolute quantification property.
Measuring Transmission Efficiencies Of Mass Spectrometers
NASA Technical Reports Server (NTRS)
Srivastava, Santosh K.
1989-01-01
Coincidence counts yield absolute efficiencies. System measures mass-dependent transmission efficiencies of mass spectrometers, using coincidence-counting techniques reminiscent of those used for many years in calibration of detectors for subatomic particles. Coincidences between detected ions and electrons producing them counted during operation of mass spectrometer. Under certain assumptions regarding inelastic scattering of electrons, electron/ion-coincidence count is direct measure of transmission efficiency of spectrometer. When fully developed, system compact, portable, and used routinely to calibrate mass spectrometers.
Kim, Joo-Hwan; Kim, Jin Ho; Wang, Pengbin; Park, Bum Soo; Han, Myung-Soo
2016-01-01
The identification and quantification of Heterosigma akashiwo cysts in sediments by light microscopy can be difficult due to the small size and morphology of the cysts, which are often indistinguishable from those of other types of algae. Quantitative real-time PCR (qPCR) based assays represent a potentially efficient method for quantifying the abundance of H. akashiwo cysts, although standard curves must be based on cyst DNA rather than on vegetative cell DNA due to differences in gene copy number and DNA extraction yield between these two cell types. Furthermore, qPCR on sediment samples can be complicated by the presence of extracellular DNA debris. To solve these problems, we constructed a cyst-based standard curve and developed a simple method for removing DNA debris from sediment samples. This cyst-based standard curve was compared with a standard curve based on vegetative cells, as vegetative cells may have twice the gene copy number of cysts. To remove DNA debris from the sediment, we developed a simple method involving dilution with distilled water and heating at 75°C. A total of 18 sediment samples were used to evaluate this method. Cyst abundance determined using the qPCR assay without DNA debris removal yielded results up to 51-fold greater than with direct counting. By contrast, a highly significant correlation was observed between cyst abundance determined by direct counting and the qPCR assay in conjunction with DNA debris removal (r2 = 0.72, slope = 1.07, p < 0.001). Therefore, this improved qPCR method should be a powerful tool for the accurate quantification of H. akashiwo cysts in sediment samples.
Kianipour, Sahar; Ardestani, Mohammad Emami; Dehghan, Parvin
2018-01-01
Candida dubliniensis is a newly diagnosed species very similar to Candida albicans phenotypically and first discovered in the mouth of people with AIDS in 1995. Among the different phenotypic and genotypic methods, a cost-effective method should be selected which makes it possible to differentiate these similar species. Polymerase chain reaction (PCR)-restriction fragment length polymorphism with MspI enzyme and the Duplex-PCR method were done by DNA extraction using boiling. The sequencing of the amplified ribosomal region was used to confirm the C. dubliniensis species. Direct examination and colony count of the yeasts were applied for bronchoalveolar lavage (BAL) samples and the growth rate of the yeasts were studied at 45°C. To understand the ability formation of chlamydoconidia in yeast isolates, they were separately cultured on the sunflower seed agar, wheat flour agar, and corn meal agar media. Fifty-nine (49.2%) yeast colonies were identified from the total of 120 BAL specimens. Twenty-nine isolated yeasts; including 17 (58.6%) of C. albicans / dubliniensis complex and 12 (41.4%) of nonalbicans isolates produced pseudohypha or blastoconidia in direct smear with a mean colony count of 42000 CFU/mL. C. albicans with the frequency of 15 (42.9%) were the most common isolated yeasts, whereas C. dubliniensis was identified in two nonHIV patients. Sequencing of the replicated gene fragment is the best method for identifying the yeasts, but the determination of the species by phenotypic methods such as the creation of chlamydoconidia in sunflower seeds agar and wheat flour agar media can be cost-effective, have sensitivity and acceptable quality.
21 CFR 1210.16 - Method of bacterial count.
Code of Federal Regulations, 2010 CFR
2010-04-01
... Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... FEDERAL IMPORT MILK ACT Inspection and Testing § 1210.16 Method of bacterial count. The bacterial count of milk and cream refers to the number of viable bacteria as determined by the standard plate method of...
21 CFR 1210.16 - Method of bacterial count.
Code of Federal Regulations, 2011 CFR
2011-04-01
... Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED... FEDERAL IMPORT MILK ACT Inspection and Testing § 1210.16 Method of bacterial count. The bacterial count of milk and cream refers to the number of viable bacteria as determined by the standard plate method of...
45 CFR 146.115 - Certification and disclosure of previous coverage.
Code of Federal Regulations, 2010 CFR
2010-10-01
... to the alternative method of counting creditable coverage). Moreover, if the individual's coverage... benefits described in § 146.113(c) (relating to the alternative method of counting creditable coverage... of coverage to a plan or issuer using the alternative method of counting creditable coverage—(1) In...
26 CFR 54.9801-5 - Evidence of creditable coverage.
Code of Federal Regulations, 2010 CFR
2010-04-01
... under paragraph (b)(2) of this section (relating to the alternative method of counting creditable... in § 54.9801-4(c) (relating to the alternative method of counting creditable coverage). However, if... Act. (b) Disclosure of coverage to a plan or issuer using the alternative method of counting...
Comparison of culture and qPCR methods in detection of mycobacteria from drinking waters.
Räsänen, Noora H J; Rintala, Helena; Miettinen, Ilkka T; Torvinen, Eila
2013-04-01
Environmental mycobacteria are common bacteria in man-made water systems and may cause infections and hypersensitivity pneumonitis via exposure to water. We compared a generally used cultivation method and a quantitative polymerase chain reaction (qPCR) method to detect mycobacteria in 3 types of drinking waters: surface water, ozone-treated surface water, and groundwater. There was a correlation between the numbers of mycobacteria obtained by cultivation and qPCR methods, but the ratio of the counts obtained by the 2 methods varied among the types of water. The qPCR counts in the drinking waters produced from surface or groundwater were 5 to 34 times higher than culturable counts. In ozone-treated surface waters, both methods gave similar counts. The ozone-treated drinking waters had the highest concentration of assimilable organic carbon, which may explain the good culturability. In warm tap waters, qPCR gave 43 times higher counts than cultivation, but both qPCR counts and culturable counts were lower than those in the drinking waters collected from the same sites. The TaqMan qPCR method is a rapid and sensitive tool for total quantitation of mycobacteria in different types of clean waters. The raw water source and treatments affect both culturability and total numbers of mycobacteria in drinking waters.
Inferences about landbird abundance from count data: recent advances and future directions
Nichols, J.D.; Thomas, L.; Conn, P.B.; Thomson, David L.; Cooch, Evan G.; Conroy, Michael J.
2009-01-01
We summarize results of a November 2006 workshop dealing with recent research on the estimation of landbird abundance from count data. Our conceptual framework includes a decomposition of the probability of detecting a bird potentially exposed to sampling efforts into four separate probabilities. Primary inference methods are described and include distance sampling, multiple observers, time of detection, and repeated counts. The detection parameters estimated by these different approaches differ, leading to different interpretations of resulting estimates of density and abundance. Simultaneous use of combinations of these different inference approaches can not only lead to increased precision but also provides the ability to decompose components of the detection process. Recent efforts to test the efficacy of these different approaches using natural systems and a new bird radio test system provide sobering conclusions about the ability of observers to detect and localize birds in auditory surveys. Recent research is reported on efforts to deal with such potential sources of error as bird misclassification, measurement error, and density gradients. Methods for inference about spatial and temporal variation in avian abundance are outlined. Discussion topics include opinions about the need to estimate detection probability when drawing inference about avian abundance, methodological recommendations based on the current state of knowledge and suggestions for future research.
DIRECT COUPLED PROGRESSIVE STAGE PULSE COUNTER APPARATUS
Kaufman, W.M.
1962-08-14
A progressive electrical pulse counter circuit was designed for the counting of a chain of input pulses of random width and/or frequency. The circuit employs an odd and even pulse input line alternately connected to a series of directly connected bistable counting stages. Each bistable stage has two d-c operative states which stage, when in its rnrtial state, prevents the next succeeding stage from changing its condition when the latter stage is pulsed. Since only altennate stages are pulsed for each incoming pulse, only one stage will change its state for each input pulse thereby providing prog essive stage by stage counting. (AEC)
High resolution time interval meter
Martin, A.D.
1986-05-09
Method and apparatus are provided for measuring the time interval between two events to a higher resolution than reliability available from conventional circuits and component. An internal clock pulse is provided at a frequency compatible with conventional component operating frequencies for reliable operation. Lumped constant delay circuits are provided for generating outputs at delay intervals corresponding to the desired high resolution. An initiation START pulse is input to generate first high resolution data. A termination STOP pulse is input to generate second high resolution data. Internal counters count at the low frequency internal clock pulse rate between the START and STOP pulses. The first and second high resolution data are logically combined to directly provide high resolution data to one counter and correct the count in the low resolution counter to obtain a high resolution time interval measurement.
Takeshita, Kazutaka; Ikeda, Takashi; Takahashi, Hiroshi; Yoshida, Tsuyoshi; Igota, Hiromasa; Matsuura, Yukiko; Kaji, Koichi
2016-01-01
Assessing temporal changes in abundance indices is an important issue in the management of large herbivore populations. The drive counts method has been frequently used as a deer abundance index in mountainous regions. However, despite an inherent risk for observation errors in drive counts, which increase with deer density, evaluations of the utility of drive counts at a high deer density remain scarce. We compared the drive counts and mark-resight (MR) methods in the evaluation of a highly dense sika deer population (MR estimates ranged between 11 and 53 individuals/km2) on Nakanoshima Island, Hokkaido, Japan, between 1999 and 2006. This deer population experienced two large reductions in density; approximately 200 animals in total were taken from the population through a large-scale population removal and a separate winter mass mortality event. Although the drive counts tracked temporal changes in deer abundance on the island, they overestimated the counts for all years in comparison to the MR method. Increased overestimation in drive count estimates after the winter mass mortality event may be due to a double count derived from increased deer movement and recovery of body condition secondary to the mitigation of density-dependent food limitations. Drive counts are unreliable because they are affected by unfavorable factors such as bad weather, and they are cost-prohibitive to repeat, which precludes the calculation of confidence intervals. Therefore, the use of drive counts to infer the deer abundance needs to be reconsidered.
A method to stabilise the performance of negatively fed KM3NeT photomultipliers
NASA Astrophysics Data System (ADS)
Adrián-Martínez, S.; Ageron, M.; Aiello, S.; Albert, A.; Ameli, F.; Anassontzis, E. G.; Andre, M.; Androulakis, G.; Anghinolfi, M.; Anton, G.; Ardid, M.; Avgitas, T.; Barbarino, G.; Barbarito, E.; Baret, B.; Barrios-Martí, J.; Belias, A.; Berbee, E.; van den Berg, A.; Bertin, V.; Beurthey, S.; van Beveren, V.; Beverini, N.; Biagi, S.; Biagioni, A.; Billault, M.; Bondì, M.; Bormuth, R.; Bouhadef, B.; Bourlis, G.; Bourret, S.; Boutonnet, C.; Bouwhuis, M.; Bozza, C.; Bruijn, R.; Brunner, J.; Buis, E.; Buompane, R.; Busto, J.; Cacopardo, G.; Caillat, L.; Calamai, M.; Calvo, D.; Capone, A.; Caramete, L.; Cecchini, S.; Celli, S.; Champion, C.; Cherubini, S.; Chiarella, V.; Chiarelli, L.; Chiarusi, T.; Circella, M.; Classen, L.; Cobas, D.; Cocimano, R.; Coelho, J. A. B.; Coleiro, A.; Colonges, S.; Coniglione, R.; Cordelli, M.; Cosquer, A.; Coyle, P.; Creusot, A.; Cuttone, G.; D'Amato, C.; D'Amico, A.; D'Onofrio, A.; De Bonis, G.; De Sio, C.; Di Capua, F.; Di Palma, I.; Distefano, C.; Donzaud, C.; Dornic, D.; Dorosti-Hasankiadeh, Q.; Drakopoulou, E.; Drouhin, D.; Durocher, M.; Eberl, T.; Eichie, S.; van Eijk, D.; El Bojaddaini, I.; Elsaesser, D.; Enzenhöfer, A.; Favaro, M.; Fermani, P.; Ferrara, G.; Frascadore, G.; Furini, M.; Fusco, L. A.; Gal, T.; Galatà, S.; Garufi, F.; Gay, P.; Gebyehu, M.; Giacomini, F.; Gialanella, L.; Giordano, V.; Gizani, N.; Gracia, R.; Graf, K.; Grégoire, T.; Grella, G.; Grmek, A.; Guerzoni, M.; Habel, R.; Hallmann, S.; van Haren, H.; Harissopulos, S.; Heid, T.; Heijboer, A.; Heine, E.; Henry, S.; Hernández-Rey, J. J.; Hevinga, M.; Hofestädt, J.; Hugon, C. M. F.; Illuminati, G.; James, C. W.; Jansweijer, P.; Jongen, M.; de Jong, M.; Kadler, M.; Kalekin, O.; Kappes, A.; Katz, U. F.; Keller, P.; Kieft, G.; Kießling, D.; Koffeman, E. N.; Kooijman, P.; Kouchner, A.; Kreter, M.; Kulikovskiy, V.; Lahmann, R.; Lamare, P.; Leisos, A.; Leonora, E.; Clark, M. Lindsey; Liolios, A.; Llorens Alvarez, C. D.; Lo Presti, D.; Löhner, H.; Lonardo, A.; Lotze, M.; Loucatos, S.; Maccioni, E.; Mannheim, K.; Manzali, M.; Margiotta, A.; Margotti, A.; Marinelli, A.; Mariš, O.; Markou, C.; Martínez-Mora, J. A.; Martini, A.; Marzaioli, F.; Mele, R.; Melis, K. W.; Michael, T.; Migliozzi, P.; Migneco, E.; Mijakowski, P.; Miraglia, A.; Mollo, C. M.; Mongelli, M.; Morganti, M.; Moussa, A.; Musico, P.; Musumeci, M.; Nicolau, C. A.; Olcina, I.; Olivetto, C.; Orlando, A.; Orzelli, A.; Pancaldi, G.; Paolucci, A.; Papaikonomou, A.; Papaleo, R.; Păvălaš, G. E.; Peek, H.; Pellegrini, G.; Pellegrino, C.; Perrina, C.; Pfutzner, M.; Piattelli, P.; Pikounis, K.; Poma, G. E.; Popa, V.; Pradier, T.; Pratolongo, F.; Pühlhofer, G.; Pulvirenti, S.; Quinn, L.; Racca, C.; Raffaelli, F.; Randazzo, N.; Real, D.; Resvanis, L.; Reubelt, J.; Riccobene, G.; Rossi, C.; Rovelli, A.; Saldaña, M.; Salvadori, I.; Samtleben, D. F. E.; Sánchez García, A.; Sánchez Losa, A.; Sanguineti, M.; Santangelo, A.; Santonocito, D.; Sapienza, P.; Schimmel, F.; Schmelling, J.; Schnabel, J.; Sciacca, V.; Sedita, M.; Seitz, T.; Sgura, I.; Simeone, F.; Sipala, V.; Spisso, B.; Spurio, M.; Stavropoulos, G.; Steijger, J.; Stellacci, S. M.; Stransky, D.; Taiuti, M.; Tayalati, Y.; Terrasi, F.; Tézier, D.; Theraube, S.; Timmer, P.; Töonnis, C.; Trasatti, L.; Travaglini, R.; Trovato, A.; Tsirigotis, A.; Tzamarias, S.; Tzamariudaki, E.; Vallage, B.; Van Elewyck, V.; Vermeulen, J.; Versari, F.; Vicini, P.; Viola, S.; Vivolo, D.; Volkert, M.; Wiggers, L.; Wilms, J.; de Wolf, E.; Zachariadou, K.; Zani, S.; Zornoza, J. D.; Zúñiga, J.
2016-12-01
The KM3NeT research infrastructure, currently under construction in the Mediterranean Sea, will host neutrino telescopes for the identification of neutrino sources in the Universe and for studies of the neutrino mass hierarchy. These telescopes will house hundreds of thousands of photomultiplier tubes that will have to be operated in a stable and reliable fashion. In this context, the stability of the dark counts has been investigated for photomultiplier tubes with negative high voltage on the photocathode and held in insulating support structures made of 3D printed nylon material. Small gaps between the rigid support structure and the photomultiplier tubes in the presence of electric fields can lead to discharges that produce dark count rates that are highly variable. A solution was found by applying the same insulating varnish as used for the high voltage bases directly to the outside of the photomultiplier tubes. This transparent conformal coating provides a convenient and inexpensive method of insulation.
Counting pollen grains using readily available, free image processing and analysis software.
Costa, Clayton M; Yang, Suann
2009-10-01
Although many methods exist for quantifying the number of pollen grains in a sample, there are few standard methods that are user-friendly, inexpensive and reliable. The present contribution describes a new method of counting pollen using readily available, free image processing and analysis software. Pollen was collected from anthers of two species, Carduus acanthoides and C. nutans (Asteraceae), then illuminated on slides and digitally photographed through a stereomicroscope. Using ImageJ (NIH), these digital images were processed to remove noise and sharpen individual pollen grains, then analysed to obtain a reliable total count of the number of grains present in the image. A macro was developed to analyse multiple images together. To assess the accuracy and consistency of pollen counting by ImageJ analysis, counts were compared with those made by the human eye. Image analysis produced pollen counts in 60 s or less per image, considerably faster than counting with the human eye (5-68 min). In addition, counts produced with the ImageJ procedure were similar to those obtained by eye. Because count parameters are adjustable, this image analysis protocol may be used for many other plant species. Thus, the method provides a quick, inexpensive and reliable solution to counting pollen from digital images, not only reducing the chance of error but also substantially lowering labour requirements.
Himle, Michael B; Chang, Susanna; Woods, Douglas W; Pearlman, Amanda; Buzzella, Brian; Bunaciu, Liviu; Piacentini, John C
2006-01-01
Behavior analysis has been at the forefront in establishing effective treatments for children and adults with chronic tic disorders. As is customary in behavior analysis, the efficacy of these treatments has been established using direct-observation assessment methods. Although behavior-analytic treatments have enjoyed acceptance and integration into mainstream health care practices for tic disorders (e.g., psychiatry and neurology), the use of direct observation as a primary assessment tool has been neglected in favor of less objective methods. Hesitation to use direct observation appears to stem largely from concerns about the generalizability of clinic observations to other settings (e.g., home) and a lack of consensus regarding the most appropriate and feasible techniques for conducting and scoring direct observation. The purpose of the current study was to evaluate and establish a reliable, valid, and feasible direct-observation protocol capable of being transported to research and clinical settings. A total of 43 children with tic disorders, collected from two outpatient specialty clinics, were assessed using direct (videotape samples) and indirect (Yale Global Tic Severity Scale; YGTSS) methods. Videotaped observation samples were collected across 3 consecutive weeks and two different settings (clinic and home), were scored using both exact frequency counts and partial-interval coding, and were compared to data from a common indirect measure of tic severity (the YGTSS). In addition, various lengths of videotaped segments were scored to determine the optimal observation length. Results show that (a) clinic-based observations correspond well to home-based observations, (b) brief direct-observation segments scored with time-sampling methods reliably quantified tics, and (c) indirect methods did not consistently correspond with the direct methods.
A new model to predict weak-lensing peak counts. II. Parameter constraint strategies
NASA Astrophysics Data System (ADS)
Lin, Chieh-An; Kilbinger, Martin
2015-11-01
Context. Peak counts have been shown to be an excellent tool for extracting the non-Gaussian part of the weak lensing signal. Recently, we developed a fast stochastic forward model to predict weak-lensing peak counts. Our model is able to reconstruct the underlying distribution of observables for analysis. Aims: In this work, we explore and compare various strategies for constraining a parameter using our model, focusing on the matter density Ωm and the density fluctuation amplitude σ8. Methods: First, we examine the impact from the cosmological dependency of covariances (CDC). Second, we perform the analysis with the copula likelihood, a technique that makes a weaker assumption than does the Gaussian likelihood. Third, direct, non-analytic parameter estimations are applied using the full information of the distribution. Fourth, we obtain constraints with approximate Bayesian computation (ABC), an efficient, robust, and likelihood-free algorithm based on accept-reject sampling. Results: We find that neglecting the CDC effect enlarges parameter contours by 22% and that the covariance-varying copula likelihood is a very good approximation to the true likelihood. The direct techniques work well in spite of noisier contours. Concerning ABC, the iterative process converges quickly to a posterior distribution that is in excellent agreement with results from our other analyses. The time cost for ABC is reduced by two orders of magnitude. Conclusions: The stochastic nature of our weak-lensing peak count model allows us to use various techniques that approach the true underlying probability distribution of observables, without making simplifying assumptions. Our work can be generalized to other observables where forward simulations provide samples of the underlying distribution.
Fractal analysis of mandibular trabecular bone: optimal tile sizes for the tile counting method
Huh, Kyung-Hoe; Baik, Jee-Seon; Heo, Min-Suk; Lee, Sam-Sun; Choi, Soon-Chul; Lee, Sun-Bok; Lee, Seung-Pyo
2011-01-01
Purpose This study was performed to determine the optimal tile size for the fractal dimension of the mandibular trabecular bone using a tile counting method. Materials and Methods Digital intraoral radiographic images were obtained at the mandibular angle, molar, premolar, and incisor regions of 29 human dry mandibles. After preprocessing, the parameters representing morphometric characteristics of the trabecular bone were calculated. The fractal dimensions of the processed images were analyzed in various tile sizes by the tile counting method. Results The optimal range of tile size was 0.132 mm to 0.396 mm for the fractal dimension using the tile counting method. The sizes were closely related to the morphometric parameters. Conclusion The fractal dimension of mandibular trabecular bone, as calculated with the tile counting method, can be best characterized with a range of tile sizes from 0.132 to 0.396 mm. PMID:21977478
Estimates for Pu-239 loadings in burial ground culverts based on fast/slow neutron measurements
DOE Office of Scientific and Technical Information (OSTI.GOV)
Winn, W.G.; Hochel, R.C.; Hofstetter, K.J.
1989-08-15
This report provides guideline estimates for Pu-239 mass loadings in selected burial ground culverts. The relatively high recorded Pu-239 contents of these culverts have been appraised as suspect relative to criticality concerns, because they were assayed only with the solid waste monitor (SWM) per gamma-ray counting. After 1985, subsequent waste was also assayed with the neutron coincidence counter (NCC), and a comparison of the assay methods showed that the NCC generally yielded higher assays than the SWM. These higher NCC readings signaled a need to conduct non-destructive/non-intrusive nuclear interrogations of these culverts, and a technical team conducted scoping measurements tomore » illustrate potential assay methods based on neutron and/or gamma counting. A fast/slow neutron method has been developed to estimate the Pu-239 in the culverts. In addition, loading records include the SWM assays of all Pu-239 cuts of some of the culvert drums and these data are useful in estimating the corresponding NCC drum assays from NCC vs SWM data. Together, these methods yield predictions based on direct measurements and statistical inference.« less
Can reliable sage-grouse lek counts be obtained using aerial infrared technology
Gillette, Gifford L.; Coates, Peter S.; Petersen, Steven; Romero, John P.
2013-01-01
More effective methods for counting greater sage-grouse (Centrocercus urophasianus) are needed to better assess population trends through enumeration or location of new leks. We describe an aerial infrared technique for conducting sage-grouse lek counts and compare this method with conventional ground-based lek count methods. During the breeding period in 2010 and 2011, we surveyed leks from fixed-winged aircraft using cryogenically cooled mid-wave infrared cameras and surveyed the same leks on the same day from the ground following a standard lek count protocol. We did not detect significant differences in lek counts between surveying techniques. These findings suggest that using a cryogenically cooled mid-wave infrared camera from an aerial platform to conduct lek surveys is an effective alternative technique to conventional ground-based methods, but further research is needed. We discuss multiple advantages to aerial infrared surveys, including counting in remote areas, representing greater spatial variation, and increasing the number of counted leks per season. Aerial infrared lek counts may be a valuable wildlife management tool that releases time and resources for other conservation efforts. Opportunities exist for wildlife professionals to refine and apply aerial infrared techniques to wildlife monitoring programs because of the increasing reliability and affordability of this technology.
Comparing census methods for the endangered Kirtland's Warbler
John R. Probst; Deahn M. Donner; Mike Worland; Jerry Weinrich; Phillip Huber; Kenneth R. Ennis
2005-01-01
We compared transect counts used for the annual official count of male Kirtland`s Warblers (Dendroica kirtlandii) to an observation-based mapping method of individually sighted males in 155 stands over 10 yrs. The annual census count almost tripled from 1990 to 1999. The transect and observation-based mapping method showed the same increasing trend...
Enhanced Methodologies to Enumerate Persons Experiencing Homelessness in a Large Urban Area.
Troisi, Catherine L; D'Andrea, Ritalinda; Grier, Gary; Williams, Stephen
2015-10-01
Homelessness is a public health problem, and persons experiencing homelessness are a vulnerable population. Estimates of the number of persons experiencing homelessness inform funding allocations and services planning and directly determine the ability of a community to intervene effectively in homelessness. The point-in-time (PIT) count presents a logistical problem in large urban areas, particularly those covering a vast geographical area. Working together, academia, local government, and community organizations improved the methodology for the count. Specific enhancements include use of incident command system (ICS), increased number of staging areas/teams, specialized outreach and Special Weapons and Tactics teams, and day-after surveying to collect demographic information. This collaboration and enhanced methodology resulted in a more accurate estimate of the number of persons experiencing homelessness and allowed comparison of findings for 4 years. While initial results showed an increase due to improved counting, the number of persons experiencing homelessness counted for the subsequent years showed significant decrease during the same time period as a "housing first" campaign was implemented. The collaboration also built capacity in each sector: The health department used ICS as a training opportunity; the academics enhanced their community health efforts; the service sector was taught and implemented more rigorous quantitative methods; and the community was exposed to public health as a pragmatic and effective discipline. Improvements made to increase the reliability of the PIT count can be adapted for use in other jurisdictions, leading to improved counts and better evaluation of progress in ending homelessness. © The Author(s) 2015.
Transition Years Count: An Adolescent Profile. KIDS COUNT County Data Book, 1999.
ERIC Educational Resources Information Center
Kentucky Youth Advocates, Inc., Louisville.
This Kids Count data book is the ninth to examine trends in the well-being of Kentucky children, focusing on the transition period of adolescence, based on the view that lessons learned and foundations laid in early adolescence directly impact the transition to adulthood. This statistical portrait is based on trends in indicators of well-being in…
Brown, M A; Brown, A H; Jackson, W G; Miesner, J R
2001-07-01
Milk yield and quality were observed on 93 Angus, Brahman, and reciprocal-cross cows over 3 yr to evaluate the interactions of direct and maternal breed effects and heterosis with forage environment. Forage environments were common bermudagrass (BG), endophyte-infected tall fescue (E+), and a rotational system (ROT) of both forages, in which each forage (BG or E+) was grazed during its appropriate season, usually June through October for BG and November through May for E+. Milk yield was estimated each of 6 mo (April through September) via milking machine and converted to a 24-h basis. Milk fat, milk protein, and somatic cell count were analyzed by a commercial laboratory. Heterosis for milk yield was similar among forages, averaging 2.4 kg (P < 0.01). Expressed as percentages of purebred means, heterosis for milk yield was largest on E+ (52.8%), intermediate on ROT (39.3%), and smallest on BG (23.7%). Direct breed effects for milk yield favored Brahman, and they were similar among forages but tended to be larger for E+ (2.5 kg) and ROT (2.8 kg) than for BG (1.3 kg). Direct breed effects for milk fat favored Brahman and were similar among forages but tended to be larger for E+ (1.0%) and ROT (1.0%) than for BG (0.6%). Purebred cows exceeded crossbreds in milk protein by 0.1% on ROT (P < 0.10). Crossbred cows had lower somatic cell counts than purebreds on BG (P < 0.05), E+ (P < 0.01), or ROT (P > 0.30). Heterosis for somatic cell counts as percentages of purebred means was similar for BG (-68.3%) and E+ (-68.9%) and less favorable for ROT (-31.6%). Maternal breed effects for somatic cell count favored Angus on ROT (P < 0.10) with a similar nonsignificant trend on BG and E+. Direct breed effects for somatic cell count favored Brahman on ROT (P < 0.10) with similar nonsignificant trends on BG and E+. These results suggested that a rotation of cows from E+ to BG in the summer can partially alleviate negative effects of E+ on milk yield. Conclusions also indicated an advantage to crossbred cows in somatic cell count and provided evidence of both direct and maternal breed effects for this trait. The results also suggested that direct breed effects for milk yield, milk fat, and somatic cell count and heterosis for milk yield and somatic cell count (as percentages of purebred means) tended to vary with forage environment, indicating a potential for genotype x environment interaction for these traits.
Mapping of bird distributions from point count surveys
Sauer, J.R.; Pendleton, G.W.; Orsillo, Sandra; Ralph, C.J.; Sauer, J.R.; Droege, S.
1995-01-01
Maps generated from bird survey data are used for a variety of scientific purposes, but little is known about their bias and precision. We review methods for preparing maps from point count data and appropriate sampling methods for maps based on point counts. Maps based on point counts can be affected by bias associated with incomplete counts, primarily due to changes in proportion counted as a function of observer or habitat differences. Large-scale surveys also generally suffer from regional and temporal variation in sampling intensity. A simulated surface is used to demonstrate sampling principles for maps.
Veta, Mitko; van Diest, Paul J.; Jiwa, Mehdi; Al-Janabi, Shaimaa; Pluim, Josien P. W.
2016-01-01
Background Tumor proliferation speed, most commonly assessed by counting of mitotic figures in histological slide preparations, is an important biomarker for breast cancer. Although mitosis counting is routinely performed by pathologists, it is a tedious and subjective task with poor reproducibility, particularly among non-experts. Inter- and intraobserver reproducibility of mitosis counting can be improved when a strict protocol is defined and followed. Previous studies have examined only the agreement in terms of the mitotic count or the mitotic activity score. Studies of the observer agreement at the level of individual objects, which can provide more insight into the procedure, have not been performed thus far. Methods The development of automatic mitosis detection methods has received large interest in recent years. Automatic image analysis is viewed as a solution for the problem of subjectivity of mitosis counting by pathologists. In this paper we describe the results from an interobserver agreement study between three human observers and an automatic method, and make two unique contributions. For the first time, we present an analysis of the object-level interobserver agreement on mitosis counting. Furthermore, we train an automatic mitosis detection method that is robust with respect to staining appearance variability and compare it with the performance of expert observers on an “external” dataset, i.e. on histopathology images that originate from pathology labs other than the pathology lab that provided the training data for the automatic method. Results The object-level interobserver study revealed that pathologists often do not agree on individual objects, even if this is not reflected in the mitotic count. The disagreement is larger for objects from smaller size, which suggests that adding a size constraint in the mitosis counting protocol can improve reproducibility. The automatic mitosis detection method can perform mitosis counting in an unbiased way, with substantial agreement with human experts. PMID:27529701
NASA Astrophysics Data System (ADS)
Stogdale, Nick; Hollock, Steve; Johnson, Neil; Sumpter, Neil
2003-09-01
A 16x16 element un-cooled pyroelectric detector array has been developed which, when allied with advanced tracking and detection algorithms, has created a universal detector with multiple applications. Low-cost manufacturing techniques are used to fabricate a hybrid detector, intended for economic use in commercial markets. The detector has found extensive application in accurate people counting, detection, tracking, secure area protection, directional sensing and area violation; topics which are all pertinent to the provision of Homeland Security. The detection and tracking algorithms have, when allied with interpolation techniques, allowed a performance much higher than might be expected from a 16x16 array. This paper reviews the technology, with particular attention to the array structure, algorithms and interpolation techniques and outlines its application in a number of challenging market areas. Viewed from above, moving people are seen as 'hot blobs' moving through the field of view of the detector; background clutter or stationary objects are not seen and the detector works irrespective of lighting or environmental conditions. Advanced algorithms detect the people and extract size, shape, direction and velocity vectors allowing the number of people to be detected and their trajectories of motion to be tracked. Provision of virtual lines in the scene allows bi-directional counting of people flowing in and out of an entrance or area. Definition of a virtual closed area in the scene allows counting of the presence of stationary people within a defined area. Definition of 'counting lines' allows the counting of people, the ability to augment access control devices by confirming a 'one swipe one entry' judgement and analysis of the flow and destination of moving people. For example, passing the 'wrong way' up a denied passageway can be detected. Counting stationary people within a 'defined area' allows the behaviour and size of groups of stationary people to be analysed and counted, an alarm condition can also be generated when people stray into such areas.
Assessment and Selection of Competing Models for Zero-Inflated Microbiome Data
Xu, Lizhen; Paterson, Andrew D.; Turpin, Williams; Xu, Wei
2015-01-01
Typical data in a microbiome study consist of the operational taxonomic unit (OTU) counts that have the characteristic of excess zeros, which are often ignored by investigators. In this paper, we compare the performance of different competing methods to model data with zero inflated features through extensive simulations and application to a microbiome study. These methods include standard parametric and non-parametric models, hurdle models, and zero inflated models. We examine varying degrees of zero inflation, with or without dispersion in the count component, as well as different magnitude and direction of the covariate effect on structural zeros and the count components. We focus on the assessment of type I error, power to detect the overall covariate effect, measures of model fit, and bias and effectiveness of parameter estimations. We also evaluate the abilities of model selection strategies using Akaike information criterion (AIC) or Vuong test to identify the correct model. The simulation studies show that hurdle and zero inflated models have well controlled type I errors, higher power, better goodness of fit measures, and are more accurate and efficient in the parameter estimation. Besides that, the hurdle models have similar goodness of fit and parameter estimation for the count component as their corresponding zero inflated models. However, the estimation and interpretation of the parameters for the zero components differs, and hurdle models are more stable when structural zeros are absent. We then discuss the model selection strategy for zero inflated data and implement it in a gut microbiome study of > 400 independent subjects. PMID:26148172
Assessment and Selection of Competing Models for Zero-Inflated Microbiome Data.
Xu, Lizhen; Paterson, Andrew D; Turpin, Williams; Xu, Wei
2015-01-01
Typical data in a microbiome study consist of the operational taxonomic unit (OTU) counts that have the characteristic of excess zeros, which are often ignored by investigators. In this paper, we compare the performance of different competing methods to model data with zero inflated features through extensive simulations and application to a microbiome study. These methods include standard parametric and non-parametric models, hurdle models, and zero inflated models. We examine varying degrees of zero inflation, with or without dispersion in the count component, as well as different magnitude and direction of the covariate effect on structural zeros and the count components. We focus on the assessment of type I error, power to detect the overall covariate effect, measures of model fit, and bias and effectiveness of parameter estimations. We also evaluate the abilities of model selection strategies using Akaike information criterion (AIC) or Vuong test to identify the correct model. The simulation studies show that hurdle and zero inflated models have well controlled type I errors, higher power, better goodness of fit measures, and are more accurate and efficient in the parameter estimation. Besides that, the hurdle models have similar goodness of fit and parameter estimation for the count component as their corresponding zero inflated models. However, the estimation and interpretation of the parameters for the zero components differs, and hurdle models are more stable when structural zeros are absent. We then discuss the model selection strategy for zero inflated data and implement it in a gut microbiome study of > 400 independent subjects.
Accurate phase measurements for thick spherical objects using optical quadrature microscopy
NASA Astrophysics Data System (ADS)
Warger, William C., II; DiMarzio, Charles A.
2009-02-01
In vitro fertilization (IVF) procedures have resulted in the birth of over three million babies since 1978. Yet the live birth rate in the United States was only 34% in 2005, with 32% of the successful pregnancies resulting in multiple births. These multiple pregnancies were directly attributed to the transfer of multiple embryos to increase the probability that a single, healthy embryo was included. Current viability markers used for IVF, such as the cell number, symmetry, size, and fragmentation, are analyzed qualitatively with differential interference contrast (DIC) microscopy. However, this method is not ideal for quantitative measures beyond the 8-cell stage of development because the cells overlap and obstruct the view within and below the cluster of cells. We have developed the phase-subtraction cell-counting method that uses the combination of DIC and optical quadrature microscopy (OQM) to count the number of cells accurately in live mouse embryos beyond the 8-cell stage. We have also created a preliminary analysis to measure the cell symmetry, size, and fragmentation quantitatively by analyzing the relative dry mass from the OQM image in conjunction with the phase-subtraction count. In this paper, we will discuss the characterization of OQM with respect to measuring the phase accurately for spherical samples that are much larger than the depth of field. Once fully characterized and verified with human embryos, this methodology could provide the means for a more accurate method to score embryo viability.
Background compensation for a radiation level monitor
Keefe, D.J.
1975-12-01
Background compensation in a device such as a hand and foot monitor is provided by digital means using a scaler. With no radiation level test initiated, a scaler is down-counted from zero according to the background measured. With a radiation level test initiated, the scaler is up-counted from the previous down-count position according to the radiation emitted from the monitored object and an alarm is generated if, with the scaler having crossed zero in the positive going direction, a particular number is exceeded in a specific time period after initiation of the test. If the test is initiated while the scale is down-counting, the background count from the previous down- count stored in a memory is used as the initial starting point for the up-count.
Spatiotemporal Dynamics of Total Viable Vibrio spp. in a NW Mediterranean Coastal Area.
Girard, Léa; Peuchet, Sébastien; Servais, Pierre; Henry, Annabelle; Charni-Ben-Tabassi, Nadine; Baudart, Julia
2017-09-27
A cellular approach combining Direct Viable Counting and Fluorescent In Situ Hybridization using a one-step multiple-probe technique and Solid Phase Cytometry (DVC-FISH-SPC) was developed to monitor total viable vibrios and cover the detection of a large diversity of vibrios. FISH combined three probes in the same assay and targeted sequences located at different positions on the 16S rRNA of Vibrio and Aliivibrio members. We performed a 10-month in situ study to investigate the weekly dynamics of viable vibrios relative to culturable counts at two northwestern Mediterranean coastal sites, and identified the key physicochemical factors for their occurrence in water using a multivariate analysis. Total viable and culturable cell counts showed the same temporal pattern during the warmer season, whereas the ratios between both methods were inverted during the colder seasons (<15°C), indicating that some of the vibrio community had entered into a viable but non-culturable (VBNC) state. We confirmed that Seawater Surface Temperature explained 51-62% of the total variance in culturable counts, and also showed that the occurrence of viable vibrios is controlled by two variables, pheopigment (15%) and phosphate (12%) concentrations, suggesting that other unidentified factors play a role in maintaining viability.
No control genes required: Bayesian analysis of qRT-PCR data.
Matz, Mikhail V; Wright, Rachel M; Scott, James G
2013-01-01
Model-based analysis of data from quantitative reverse-transcription PCR (qRT-PCR) is potentially more powerful and versatile than traditional methods. Yet existing model-based approaches cannot properly deal with the higher sampling variances associated with low-abundant targets, nor do they provide a natural way to incorporate assumptions about the stability of control genes directly into the model-fitting process. In our method, raw qPCR data are represented as molecule counts, and described using generalized linear mixed models under Poisson-lognormal error. A Markov Chain Monte Carlo (MCMC) algorithm is used to sample from the joint posterior distribution over all model parameters, thereby estimating the effects of all experimental factors on the expression of every gene. The Poisson-based model allows for the correct specification of the mean-variance relationship of the PCR amplification process, and can also glean information from instances of no amplification (zero counts). Our method is very flexible with respect to control genes: any prior knowledge about the expected degree of their stability can be directly incorporated into the model. Yet the method provides sensible answers without such assumptions, or even in the complete absence of control genes. We also present a natural Bayesian analogue of the "classic" analysis, which uses standard data pre-processing steps (logarithmic transformation and multi-gene normalization) but estimates all gene expression changes jointly within a single model. The new methods are considerably more flexible and powerful than the standard delta-delta Ct analysis based on pairwise t-tests. Our methodology expands the applicability of the relative-quantification analysis protocol all the way to the lowest-abundance targets, and provides a novel opportunity to analyze qRT-PCR data without making any assumptions concerning target stability. These procedures have been implemented as the MCMC.qpcr package in R.
Takeshita, Kazutaka; Yoshida, Tsuyoshi; Igota, Hiromasa; Matsuura, Yukiko
2016-01-01
Assessing temporal changes in abundance indices is an important issue in the management of large herbivore populations. The drive counts method has been frequently used as a deer abundance index in mountainous regions. However, despite an inherent risk for observation errors in drive counts, which increase with deer density, evaluations of the utility of drive counts at a high deer density remain scarce. We compared the drive counts and mark-resight (MR) methods in the evaluation of a highly dense sika deer population (MR estimates ranged between 11 and 53 individuals/km2) on Nakanoshima Island, Hokkaido, Japan, between 1999 and 2006. This deer population experienced two large reductions in density; approximately 200 animals in total were taken from the population through a large-scale population removal and a separate winter mass mortality event. Although the drive counts tracked temporal changes in deer abundance on the island, they overestimated the counts for all years in comparison to the MR method. Increased overestimation in drive count estimates after the winter mass mortality event may be due to a double count derived from increased deer movement and recovery of body condition secondary to the mitigation of density-dependent food limitations. Drive counts are unreliable because they are affected by unfavorable factors such as bad weather, and they are cost-prohibitive to repeat, which precludes the calculation of confidence intervals. Therefore, the use of drive counts to infer the deer abundance needs to be reconsidered. PMID:27711181
Recommended methods for monitoring change in bird populations by counting and capture of migrants
David J. T. Hussell; C. John Ralph
2005-01-01
Counts and banding captures of spring or fall migrants can generate useful information on the status and trends of the source populations. To do so, the counts and captures must be taken and recorded in a standardized and consistent manner. We present recommendations for field methods for counting and capturing migrants at intensively operated sites, such as bird...
NASA Astrophysics Data System (ADS)
Damialis, Athanasios; Gioulekas, Dimitrios; Lazopoulou, Chariklia; Balafoutis, Christos; Vokou, Despina
2005-01-01
We examined the effect of the wind vector analyzed into its three components (direction, speed and persistence), on the circulation of pollen from differe nt plant taxa prominent in the Thessaloniki area for a 4-year period (1996- 1999). These plant taxa were Ambrosia spp., Artemisia spp., Chenopodiaceae, spp., Cupressaceae, Olea europaea, Pinaceae, Platanus spp., Poaceae, Populus spp., Quercus spp., and Urticaceae. Airborne pollen of Cupressaceae, Urticaceae, Quercus spp. and O. europaea make up approximately 70% of the total average annual pollen counts. The set of data that we worked with represented days without precipitation and time intervals during which winds blew from the same direction for at least 4 consecutive hours. We did this in order to study the effect of the different wind components independently of precipitation, and to avoid secondary effects produced by pollen resuspension phenomena. Factorial regression analysis among the summed bi-hourly pollen counts for each taxon and the values of wind speed and persistence per wind direction gave significant results in 22 cases (combinations of plant taxa and wind directions). The pollen concentrations of all taxa correlated significantly with at least one of the three wind components. In seven out of the 22 taxon-wind direction combinations, the pollen counts correlated positively with wind persistence, whereas this was the case for only two of the taxon-wind speed combinations. In seven cases, pollen counts correlated with the interaction effect of wind speed and persistence. This shows the importance of wind persistence in pollen transport, particularly when weak winds prevail for a considerable part of the year, as is the case for Thessaloniki. Medium/long-distance pollen transport was evidenced for Olea (NW, SW directions), Corylus (NW, SW), Poaceae (SW) and Populus (NW).
Fractal analysis of mandibular trabecular bone: optimal tile sizes for the tile counting method.
Huh, Kyung-Hoe; Baik, Jee-Seon; Yi, Won-Jin; Heo, Min-Suk; Lee, Sam-Sun; Choi, Soon-Chul; Lee, Sun-Bok; Lee, Seung-Pyo
2011-06-01
This study was performed to determine the optimal tile size for the fractal dimension of the mandibular trabecular bone using a tile counting method. Digital intraoral radiographic images were obtained at the mandibular angle, molar, premolar, and incisor regions of 29 human dry mandibles. After preprocessing, the parameters representing morphometric characteristics of the trabecular bone were calculated. The fractal dimensions of the processed images were analyzed in various tile sizes by the tile counting method. The optimal range of tile size was 0.132 mm to 0.396 mm for the fractal dimension using the tile counting method. The sizes were closely related to the morphometric parameters. The fractal dimension of mandibular trabecular bone, as calculated with the tile counting method, can be best characterized with a range of tile sizes from 0.132 to 0.396 mm.
Hierarchical models of animal abundance and occurrence
Royle, J. Andrew; Dorazio, R.M.
2006-01-01
Much of animal ecology is devoted to studies of abundance and occurrence of species, based on surveys of spatially referenced sample units. These surveys frequently yield sparse counts that are contaminated by imperfect detection, making direct inference about abundance or occurrence based on observational data infeasible. This article describes a flexible hierarchical modeling framework for estimation and inference about animal abundance and occurrence from survey data that are subject to imperfect detection. Within this framework, we specify models of abundance and detectability of animals at the level of the local populations defined by the sample units. Information at the level of the local population is aggregated by specifying models that describe variation in abundance and detection among sites. We describe likelihood-based and Bayesian methods for estimation and inference under the resulting hierarchical model. We provide two examples of the application of hierarchical models to animal survey data, the first based on removal counts of stream fish and the second based on avian quadrat counts. For both examples, we provide a Bayesian analysis of the models using the software WinBUGS.
Incomplete Detection of Nonclassical Phase-Space Distributions
NASA Astrophysics Data System (ADS)
Bohmann, M.; Tiedau, J.; Bartley, T.; Sperling, J.; Silberhorn, C.; Vogel, W.
2018-02-01
We implement the direct sampling of negative phase-space functions via unbalanced homodyne measurement using click-counting detectors. The negativities significantly certify nonclassical light in the high-loss regime using a small number of detectors which cannot resolve individual photons. We apply our method to heralded single-photon states and experimentally demonstrate the most significant certification of nonclassicality for only two detection bins. By contrast, the frequently applied Wigner function fails to directly indicate such quantum characteristics for the quantum efficiencies present in our setup without applying additional reconstruction algorithms. Therefore, we realize a robust and reliable approach to characterize nonclassical light in phase space under realistic conditions.
Method and apparatus for measuring frequency and phase difference
NASA Technical Reports Server (NTRS)
Shores, Paul (Inventor); Lichtenberg, Christopher (Inventor); Kobayashi, Herbert S. (Inventor); Cunningham, Allen R. (Inventor)
1986-01-01
The present invention is a system for deriving direct digital indications of frequency and phase difference between two incoming pulse trains adaptable for collision avoidance systems or the like. A pair of radar beams are directed toward a target and corresponding beams returning therefrom are detected. A digital difference circuit forms a pulse train from the Doppler shift frequencies of each beam pair having a repetition rate functionally related to the difference in magnitude of the shift frequencies. Pulses from the pulse train are counted as a function of time. Visual indications thereof on display are correlative to target position relative to beams.
Schmitz, Christoph; Eastwood, Brian S.; Tappan, Susan J.; Glaser, Jack R.; Peterson, Daniel A.; Hof, Patrick R.
2014-01-01
Stereologic cell counting has had a major impact on the field of neuroscience. A major bottleneck in stereologic cell counting is that the user must manually decide whether or not each cell is counted according to three-dimensional (3D) stereologic counting rules by visual inspection within hundreds of microscopic fields-of-view per investigated brain or brain region. Reliance on visual inspection forces stereologic cell counting to be very labor-intensive and time-consuming, and is the main reason why biased, non-stereologic two-dimensional (2D) “cell counting” approaches have remained in widespread use. We present an evaluation of the performance of modern automated cell detection and segmentation algorithms as a potential alternative to the manual approach in stereologic cell counting. The image data used in this study were 3D microscopic images of thick brain tissue sections prepared with a variety of commonly used nuclear and cytoplasmic stains. The evaluation compared the numbers and locations of cells identified unambiguously and counted exhaustively by an expert observer with those found by three automated 3D cell detection algorithms: nuclei segmentation from the FARSIGHT toolkit, nuclei segmentation by 3D multiple level set methods, and the 3D object counter plug-in for ImageJ. Of these methods, FARSIGHT performed best, with true-positive detection rates between 38 and 99% and false-positive rates from 3.6 to 82%. The results demonstrate that the current automated methods suffer from lower detection rates and higher false-positive rates than are acceptable for obtaining valid estimates of cell numbers. Thus, at present, stereologic cell counting with manual decision for object inclusion according to unbiased stereologic counting rules remains the only adequate method for unbiased cell quantification in histologic tissue sections. PMID:24847213
Harris, Adrian L; Ullah, Roshan; Fountain, Michelle T
2017-08-01
Tetranychus urticae is a widespread polyphagous mite, found on a variety of fruit crops. Tetranychus urticae feeds on the underside of the leaves perforating plant cells and sucking the cell contents. Foliar damage and excess webbing produced by T. urticae can reduce fruit yield. Assessments of T. urticae populations while small provide reliable and accurate ways of targeting control strategies and recording their efficacy against T. urticae. The aim of this study was to evaluate four methods for extracting low levels of T. urticae from leaf samples, representative of developing infestations. These methods were compared to directly counting of mites on leaves under a dissecting microscope. These methods were ethanol washing, a modified paraffin/ethanol meniscus technique, Tullgren funnel extraction and the Henderson and McBurnie mite brushing machine with consideration to: accuracy, precision and simplicity. In addition, two physically different leaf morphologies were compared; Prunus leaves which are glabrous with Malus leaves which are setaceous. Ethanol extraction consistently yielded the highest numbers of mites and was the most rapid method for recovering T. urticae from leaf samples, irrespective of leaf structure. In addition the samples could be processed and stored before final counting. The advantages and disadvantages of each method are discussed in detail.
Chan, Leo Li-Ying; Smith, Tim; Kumph, Kendra A; Kuksin, Dmitry; Kessel, Sarah; Déry, Olivier; Cribbes, Scott; Lai, Ning; Qiu, Jean
2016-10-01
To ensure cell-based assays are performed properly, both cell concentration and viability have to be determined so that the data can be normalized to generate meaningful and comparable results. Cell-based assays performed in immuno-oncology, toxicology, or bioprocessing research often require measuring of multiple samples and conditions, thus the current automated cell counter that uses single disposable counting slides is not practical for high-throughput screening assays. In the recent years, a plate-based image cytometry system has been developed for high-throughput biomolecular screening assays. In this work, we demonstrate a high-throughput AO/PI-based cell concentration and viability method using the Celigo image cytometer. First, we validate the method by comparing directly to Cellometer automated cell counter. Next, cell concentration dynamic range, viability dynamic range, and consistency are determined. The high-throughput AO/PI method described here allows for 96-well to 384-well plate samples to be analyzed in less than 7 min, which greatly reduces the time required for the single sample-based automated cell counter. In addition, this method can improve the efficiency for high-throughput screening assays, where multiple cell counts and viability measurements are needed prior to performing assays such as flow cytometry, ELISA, or simply plating cells for cell culture.
Digital rotation measurement unit
Sanderson, S.N.
1983-09-30
A digital rotation indicator is disclosed for monitoring the position of a valve member having a movable actuator. The indicator utilizes mercury switches adapted to move in cooperation with the actuator. Each of the switches produces an output as it changes state when the actuator moves. A direction detection circuit is connected to the switches to produce a first digital signal indicative of the direction of rotation of the actuator. A count pulse generating circuit is also connected to the switches to produce a second digital pulse signal having count pulses corresponding to a change of state of any of the mercury switches. A reset pulse generating circuit is provided to generate a reset pulse each time a count pulse is generated. An up/down counter is connected to receive the first digital pulse signal and the second digital pulse signal and to count the pulses of the second digital pulse signal either up or down depending upon the instantaneous digital value of the first digital signal whereby a running count indicative of the movement of the actuator is maintained.
A matrix-inversion method for gamma-source mapping from gamma-count data
DOE Office of Scientific and Technical Information (OSTI.GOV)
Adsley, Ian; Burgess, Claire; Bull, Richard K
In a previous paper it was proposed that a simple matrix inversion method could be used to extract source distributions from gamma-count maps, using simple models to calculate the response matrix. The method was tested using numerically generated count maps. In the present work a 100 kBq Co{sup 60} source has been placed on a gridded surface and the count rate measured using a NaI scintillation detector. The resulting map of gamma counts was used as input to the matrix inversion procedure and the source position recovered. A multi-source array was simulated by superposition of several single-source count maps andmore » the source distribution was again recovered using matrix inversion. The measurements were performed for several detector heights. The effects of uncertainties in source-detector distances on the matrix inversion method are also examined. The results from this work give confidence in the application of the method to practical applications, such as the segregation of highly active objects amongst fuel-element debris. (authors)« less
Klingbeil, Brian T; Willig, Michael R
2015-01-01
Effective monitoring programs for biodiversity are needed to assess trends in biodiversity and evaluate the consequences of management. This is particularly true for birds and faunas that occupy interior forest and other areas of low human population density, as these are frequently under-sampled compared to other habitats. For birds, Autonomous Recording Units (ARUs) have been proposed as a supplement or alternative to point counts made by human observers to enhance monitoring efforts. We employed two strategies (i.e., simultaneous-collection and same-season) to compare point count and ARU methods for quantifying species richness and composition of birds in temperate interior forests. The simultaneous-collection strategy compares surveys by ARUs and point counts, with methods matched in time, location, and survey duration such that the person and machine simultaneously collect data. The same-season strategy compares surveys from ARUs and point counts conducted at the same locations throughout the breeding season, but methods differ in the number, duration, and frequency of surveys. This second strategy more closely follows the ways in which monitoring programs are likely to be implemented. Site-specific estimates of richness (but not species composition) differed between methods; however, the nature of the relationship was dependent on the assessment strategy. Estimates of richness from point counts were greater than estimates from ARUs in the simultaneous-collection strategy. Woodpeckers in particular, were less frequently identified from ARUs than point counts with this strategy. Conversely, estimates of richness were lower from point counts than ARUs in the same-season strategy. Moreover, in the same-season strategy, ARUs detected the occurrence of passerines at a higher frequency than did point counts. Differences between ARU and point count methods were only detected in site-level comparisons. Importantly, both methods provide similar estimates of species richness and composition for the region. Consequently, if single visits to sites or short-term monitoring are the goal, point counts will likely perform better than ARUs, especially if species are rare or vocalize infrequently. However, if seasonal or annual monitoring of sites is the goal, ARUs offer a viable alternative to standard point-count methods, especially in the context of large-scale or long-term monitoring of temperate forest birds.
Big spleens and hypersplenism: fix it or forget it?
Boyer, Thomas D; Habib, Shahid
2015-05-01
Hypersplenism is a common manifestation of portal hypertension in the cirrhotic. More than half of cirrhotics will have low platelet counts, but neutropenia is much less common. Despite being common in the cirrhotic population, the presence of hypersplenism is of little clinical consequence. The presence of hypersplenism suggests more advanced liver disease and an increase in risk of complications, but there is no data showing that correcting the hypersplenism improves patient survival. In most series, the most common indications for treating the hypersplenism is to increase platelet and white blood cell counts to allow for use of drugs that suppress the bone marrow such as interferon alpha and chemotherapeutic agents. There are several approaches used to treat hypersplenism. Portosystemic shunts are of questionable benefit. Splenectomy, either open or laparoscopically, is the most effective but is associated with a significant risk of portal vein thrombosis. Partial splenic artery embolization and radiofrequency ablation are effective methods for treating hypersplenism, but counts tend to fall back to baseline long-term. Pharmacological agents are also effective in increasing platelet counts. Development of direct acting antivirals against hepatitis C will eliminate the most common indication for treatment. We lack controlled trials designed to determine if treating the hypersplenism has benefits other than raising the platelet and white blood cell counts. In the absence of such studies, hypersplenism in most patients should be considered a laboratory abnormality and not treated, in other words forget it. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.
2013-01-01
Background High-throughput RNA sequencing (RNA-seq) offers unprecedented power to capture the real dynamics of gene expression. Experimental designs with extensive biological replication present a unique opportunity to exploit this feature and distinguish expression profiles with higher resolution. RNA-seq data analysis methods so far have been mostly applied to data sets with few replicates and their default settings try to provide the best performance under this constraint. These methods are based on two well-known count data distributions: the Poisson and the negative binomial. The way to properly calibrate them with large RNA-seq data sets is not trivial for the non-expert bioinformatics user. Results Here we show that expression profiles produced by extensively-replicated RNA-seq experiments lead to a rich diversity of count data distributions beyond the Poisson and the negative binomial, such as Poisson-Inverse Gaussian or Pólya-Aeppli, which can be captured by a more general family of count data distributions called the Poisson-Tweedie. The flexibility of the Poisson-Tweedie family enables a direct fitting of emerging features of large expression profiles, such as heavy-tails or zero-inflation, without the need to alter a single configuration parameter. We provide a software package for R called tweeDEseq implementing a new test for differential expression based on the Poisson-Tweedie family. Using simulations on synthetic and real RNA-seq data we show that tweeDEseq yields P-values that are equally or more accurate than competing methods under different configuration parameters. By surveying the tiny fraction of sex-specific gene expression changes in human lymphoblastoid cell lines, we also show that tweeDEseq accurately detects differentially expressed genes in a real large RNA-seq data set with improved performance and reproducibility over the previously compared methodologies. Finally, we compared the results with those obtained from microarrays in order to check for reproducibility. Conclusions RNA-seq data with many replicates leads to a handful of count data distributions which can be accurately estimated with the statistical model illustrated in this paper. This method provides a better fit to the underlying biological variability; this may be critical when comparing groups of RNA-seq samples with markedly different count data distributions. The tweeDEseq package forms part of the Bioconductor project and it is available for download at http://www.bioconductor.org. PMID:23965047
NASA Astrophysics Data System (ADS)
Adi, K.; Widodo, A. P.; Widodo, C. E.; Pamungkas, A.; Putranto, A. B.
2018-05-01
Traffic monitoring on road needs to be done, the counting of the number of vehicles passing the road is necessary. It is more emphasized for highway transportation management in order to prevent efforts. Therefore, it is necessary to develop a system that is able to counting the number of vehicles automatically. Video processing method is able to counting the number of vehicles automatically. This research has development a system of vehicle counting on toll road. This system includes processes of video acquisition, frame extraction, and image processing for each frame. Video acquisition is conducted in the morning, at noon, in the afternoon, and in the evening. This system employs of background subtraction and morphology methods on gray scale images for vehicle counting. The best vehicle counting results were obtained in the morning with a counting accuracy of 86.36 %, whereas the lowest accuracy was in the evening, at 21.43 %. Differences in morning and evening results are caused by different illumination in the morning and evening. This will cause the values in the image pixels to be different.
Grimaldi, E; Del Vecchio, L; Scopacasa, F; Lo Pardo, C; Capone, F; Pariante, S; Scalia, G; De Caterina, M
2009-04-01
The Abbot Cell-Dyn Sapphire is a new generation haematology analyser. The system uses optical/fluorescence flow cytometry in combination with electronic impedance to produce a full blood count. Optical and impedance are the default methods for platelet counting while automated CD61-immunoplatelet analysis can be run as selectable test. The aim of this study was to determine the platelet count performance of the three counting methods available on the instrument and to compare the results with those provided by Becton Dickinson FACSCalibur flow cytometer used as reference method. A lipid interference experiment was also performed. Linearity, carryover and precision were good, and satisfactory agreement with reference method was found for the impedance, optical and CD61-immunoplatelet analysis, although this latter provided the closest results in comparison with flow cytometry. In the lipid interference experiment, a moderate inaccuracy of optical and immunoplatelet counts was observed starting from a very high lipid value.
voom: precision weights unlock linear model analysis tools for RNA-seq read counts
2014-01-01
New normal linear modeling strategies are presented for analyzing read counts from RNA-seq experiments. The voom method estimates the mean-variance relationship of the log-counts, generates a precision weight for each observation and enters these into the limma empirical Bayes analysis pipeline. This opens access for RNA-seq analysts to a large body of methodology developed for microarrays. Simulation studies show that voom performs as well or better than count-based RNA-seq methods even when the data are generated according to the assumptions of the earlier methods. Two case studies illustrate the use of linear modeling and gene set testing methods. PMID:24485249
voom: Precision weights unlock linear model analysis tools for RNA-seq read counts.
Law, Charity W; Chen, Yunshun; Shi, Wei; Smyth, Gordon K
2014-02-03
New normal linear modeling strategies are presented for analyzing read counts from RNA-seq experiments. The voom method estimates the mean-variance relationship of the log-counts, generates a precision weight for each observation and enters these into the limma empirical Bayes analysis pipeline. This opens access for RNA-seq analysts to a large body of methodology developed for microarrays. Simulation studies show that voom performs as well or better than count-based RNA-seq methods even when the data are generated according to the assumptions of the earlier methods. Two case studies illustrate the use of linear modeling and gene set testing methods.
Higuchi Dimension of Digital Images
Ahammer, Helmut
2011-01-01
There exist several methods for calculating the fractal dimension of objects represented as 2D digital images. For example, Box counting, Minkowski dilation or Fourier analysis can be employed. However, there appear to be some limitations. It is not possible to calculate only the fractal dimension of an irregular region of interest in an image or to perform the calculations in a particular direction along a line on an arbitrary angle through the image. The calculations must be made for the whole image. In this paper, a new method to overcome these limitations is proposed. 2D images are appropriately prepared in order to apply 1D signal analyses, originally developed to investigate nonlinear time series. The Higuchi dimension of these 1D signals is calculated using Higuchi's algorithm, and it is shown that both regions of interests and directional dependencies can be evaluated independently of the whole picture. A thorough validation of the proposed technique and a comparison of the new method to the Fourier dimension, a common two dimensional method for digital images, are given. The main result is that Higuchi's algorithm allows a direction dependent as well as direction independent analysis. Actual values for the fractal dimensions are reliable and an effective treatment of regions of interests is possible. Moreover, the proposed method is not restricted to Higuchi's algorithm, as any 1D method of analysis, can be applied. PMID:21931854
A brief overview on radon measurements in drinking water.
Jobbágy, Viktor; Altzitzoglou, Timotheos; Malo, Petya; Tanner, Vesa; Hult, Mikael
2017-07-01
The aim of this paper is to present information about currently used standard and routine methods for radon analysis in drinking waters. An overview is given about the current situation and the performance of different measurement methods based on literature data. The following parameters are compared and discussed: initial sample volume and sample preparation, detection systems, minimum detectable activity, counting efficiency, interferences, measurement uncertainty, sample capacity and overall turnaround time. Moreover, the parametric levels for radon in drinking water from the different legislations and directives/guidelines on radon are presented. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.
Veta, Mitko; van Diest, Paul J; Jiwa, Mehdi; Al-Janabi, Shaimaa; Pluim, Josien P W
2016-01-01
Tumor proliferation speed, most commonly assessed by counting of mitotic figures in histological slide preparations, is an important biomarker for breast cancer. Although mitosis counting is routinely performed by pathologists, it is a tedious and subjective task with poor reproducibility, particularly among non-experts. Inter- and intraobserver reproducibility of mitosis counting can be improved when a strict protocol is defined and followed. Previous studies have examined only the agreement in terms of the mitotic count or the mitotic activity score. Studies of the observer agreement at the level of individual objects, which can provide more insight into the procedure, have not been performed thus far. The development of automatic mitosis detection methods has received large interest in recent years. Automatic image analysis is viewed as a solution for the problem of subjectivity of mitosis counting by pathologists. In this paper we describe the results from an interobserver agreement study between three human observers and an automatic method, and make two unique contributions. For the first time, we present an analysis of the object-level interobserver agreement on mitosis counting. Furthermore, we train an automatic mitosis detection method that is robust with respect to staining appearance variability and compare it with the performance of expert observers on an "external" dataset, i.e. on histopathology images that originate from pathology labs other than the pathology lab that provided the training data for the automatic method. The object-level interobserver study revealed that pathologists often do not agree on individual objects, even if this is not reflected in the mitotic count. The disagreement is larger for objects from smaller size, which suggests that adding a size constraint in the mitosis counting protocol can improve reproducibility. The automatic mitosis detection method can perform mitosis counting in an unbiased way, with substantial agreement with human experts.
The utilization of brick walls for resisting earthquake in building technology
NASA Astrophysics Data System (ADS)
Tarigan, J.; Benedicta, C.
2018-03-01
Many structures in Indonesia use reinforced concrete frames with brick walls as their infill. Commonly, the engineers consider brick walls as the partitions and count them as the non-structural elements in the structure design. However, brick walls are capable of resisting earthquake by yielding high stiffness to the structure in case the brick walls are integrated well with the frames. It will reduce the non-structural destructions that happen to structures which is one of the most frequently impacts in the earthquake. This paper will take the effects of applying brick walls as the structural elements up by comparing it with the structure using brick walls as the partitions. The modeling of the brick walls uses the equivalent spectrum method meanwhile the seismic analysis uses the respon spectrum method. The utilization of brick walls can cause the decrement of the natural period to 42%. It also reduce the structure displacements to 53% in X-direction and 67% in Y-direction and the story drifts to 57% in X-direction and 71% in Y-direction. Otherwise, it causes the increment of the base shear only up to 3% in X-direction and 7% in Y-direction.
Low-dose electron energy-loss spectroscopy using electron counting direct detectors.
Maigné, Alan; Wolf, Matthias
2018-03-01
Since the development of parallel electron energy loss spectroscopy (EELS), charge-coupled devices (CCDs) have been the default detectors for EELS. With the recent development of electron-counting direct-detection cameras, micrographs can be acquired under very low electron doses at significantly improved signal-to-noise ratio. In spectroscopy, in particular in combination with a monochromator, the signal can be extremely weak and the detection limit is principally defined by noise introduced by the detector. Here we report the use of an electron-counting direct-detection camera for EEL spectroscopy. We studied the oxygen K edge of amorphous ice and obtained a signal noise ratio up to 10 times higher than with a conventional CCD.We report the application of electron counting to record time-resolved EEL spectra of a biological protein embedded in amorphous ice, revealing chemical changes observed in situ while exposed by the electron beam. A change in the fine structure of nitrogen K and the carbon K edges were recorded during irradiation. A concentration of 3 at% nitrogen was detected with a total electron dose of only 1.7 e-/Å2, extending the boundaries of EELS signal detection at low electron doses.
Collett, B.; Bateman, F.; Bauder, W. K.; ...
2017-08-01
Here, we describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. This apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. We present details of the method, apparatus, detectors, data acquisition, and data reduction scheme, along with a discussion of the important systematic effects.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Collett, B.; Bateman, F.; Bauder, W. K.
Here, we describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. This apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. We present details of the method, apparatus, detectors, data acquisition, and data reduction scheme, along with a discussion of the important systematic effects.
Collett, B; Bateman, F; Bauder, W K; Byrne, J; Byron, W A; Chen, W; Darius, G; DeAngelis, C; Dewey, M S; Gentile, T R; Hassan, M T; Jones, G L; Komives, A; Laptev, A; Mendenhall, M P; Nico, J S; Noid, G; Park, H; Stephenson, E J; Stern, I; Stockton, K J S; Trull, C; Wietfeldt, F E; Yerozolimsky, B G
2017-08-01
We describe an apparatus used to measure the electron-antineutrino angular correlation coefficient in free neutron decay. The apparatus employs a novel measurement technique in which the angular correlation is converted into a proton time-of-flight asymmetry that is counted directly, avoiding the need for proton spectroscopy. Details of the method, apparatus, detectors, data acquisition, and data reduction scheme are presented, along with a discussion of the important systematic effects.
Comparative determination of two probiotics by QCM and OWLS-based immunosensors.
Szalontai, Helga; Adányi, Nóra; Kiss, Attila
2014-09-25
The regular consumption of foods containing probiotic bacteria has beneficial physiological effects on the health and the digestion system. There is a need for novel analytical approaches for the determination of these bacteria that are faster than the classical plate counting method. For this purpose, two label-free biosensors were investigated and presented in this paper: Quartz Crystal Microbalance (QCM) and Optical Waveguide Lightmode Spectroscopy (OWLS) based direct immunosensors were developed for real-time direct detection of probiotic bacteria in fermented dairy products. Bifidobacterium bifidum O1356 and Lactobacillus acidophilus O1132 were detected by polyclonal anti-B. bifidum IgG and anti-L. acidophilus IgG immobilized on the sensors' surface. Sulfo-LC-SPDP cross linking agent was used to bind antibodies to the gold surface of the QCM's AT-cut quartz wafer. Concerning OWLS, antibodies were covalently bound to the amino groups of the silanized surface of the waveguide by glutaraldehyde. The dynamic measuring range was found between 1.0E+3 and 5.0E+5CFUmL(-1) in 100 fold diluted fermented milk products by QCM and with OWLS. Considering the current legislation of the probiotic content in probiotic products, the two developed immunosensors can be applied for rapid quantification of L. acidophilus and B. bifidum in fermented milk. These examinations offer effective alternatives to the microbiological plate counting method. Copyright © 2014 Elsevier B.V. All rights reserved.
A portable optical reader and wall projector towards enumeration of bio-conjugated beads or cells
McArdle, Niamh A.; Kendlin, Jane L.; O’Connell, Triona M.; Ducrée, Jens
2017-01-01
Measurement of the height of a packed column of cells or beads, which can be direclty related to the number of cells or beads present in a chamber, is an important step in a number of diagnostic assays. For example, haematocrit measurements may rapidly identify anemia or polycthemia. Recently, user-friendly and cost-efficient Lab-on-a-Chip devices have been developed towards isolating and counting cell sub-populations for diagnostic purposes. In this work, we present a low-cost optical module for estimating the filling level of packed magnetic beads within a Lab-on-a-Chip device. The module is compatible with a previously introduced, disposable microfluidic chip for rapid determination of CD4+ cell counts. The device is a simple optical microscope module is manufactured by 3D printing. An objective lens directly interrogates the height of packed beads which are efficiently isolated on the finger-actuated chip. Optionally, an inexpensive, battery-powered Light Emitting Diode may project a shadow of the microfluidic chip at approximately 50-fold magnification onto a nearby surface. The reader is calibrated with the filling levels of known concentrations of paramagnetic beads within the finger actuated chip. Results in direct and projector mode are compared to measurements from a conventional, inverted white-light microscope. All three read-out methods indicate a maximum variation of 6.5% between methods. PMID:29267367
Zeidler-Erdely, Patti C.; Antonini, James M.; Meighan, Terence G.; Young, Shih-Houng; Eye, Tracy J.; Hammer, Mary Ann; Erdely, Aaron
2016-01-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable. PMID:27251196
Zeidler-Erdely, Patti C; Antonini, James M; Meighan, Terence G; Young, Shih-Houng; Eye, Tracy J; Hammer, Mary Ann; Erdely, Aaron
2016-08-01
Pulmonary toxicity studies often use bronchoalveolar lavage (BAL) to investigate potential adverse lung responses to a particulate exposure. The BAL cellular fraction is counted, using automated (i.e. Coulter Counter®), flow cytometry or manual (i.e. hemocytometer) methods, to determine inflammatory cell influx. The goal of the study was to compare the different counting methods to determine which is optimal for examining BAL cell influx after exposure by inhalation or intratracheal instillation (ITI) to different particles with varying inherent pulmonary toxicities in both rat and mouse models. General findings indicate that total BAL cell counts using the automated and manual methods tended to agree after inhalation or ITI exposure to particle samples that are relatively nontoxic or at later time points after exposure to a pneumotoxic particle when the response resolves. However, when the initial lung inflammation and cytotoxicity was high after exposure to a pneumotoxic particle, significant differences were observed when comparing cell counts from the automated, flow cytometry and manual methods. When using total BAL cell count for differential calculations from the automated method, depending on the cell diameter size range cutoff, the data suggest that the number of lung polymorphonuclear leukocytes (PMN) varies. Importantly, the automated counts, regardless of the size cutoff, still indicated a greater number of total lung PMN when compared with the manual method, which agreed more closely with flow cytometry. The results suggest that either the manual method or flow cytometry would be better suited for BAL studies where cytotoxicity is an unknown variable.
1981-01-31
geometric factor. For the low energy FSA detectors, the background counts must be subtracted from the measured (actual) counts before the geometric factor...and high energy) each provide a background measure - ment. The background counts for the low energy ESA (LE ESA) were subtracted from the other four LE...perpendicular to the spacecraft +X reference spin axis and 189.660 around from the +Z axis (with this angle measured from the +Z axis in the direction
Gerry, Alec C; Higginbotham, G E; Periera, L N; Lam, A; Shelton, C R
2011-06-01
Relative house fly, Musca domestica L., activity at three large dairies in central California was monitored during the peak fly activity period from June to August 2005 by using spot cards, fly tapes, bait traps, and Alsynite traps. Counts for all monitoring methods were significantly related at two of three dairies; with spot card counts significantly related to fly tape counts recorded the same week, and both spot card counts and fly tape counts significantly related to bait trap counts 1-2 wk later. Mean fly counts differed significantly between dairies, but a significant interaction between dairies sampled and monitoring methods used demonstrates that between-dairy comparisons are unwise. Estimate precision was determined by the coefficient of variability (CV) (or SE/mean). Using a CV = 0.15 as a desired level of estimate precision and assuming an integrate pest management (IPM) action threshold near the peak house fly activity measured by each monitoring method, house fly monitoring at a large dairy would require 12 spot cards placed in midafternoon shaded fly resting sites near cattle or seven bait traps placed in open areas near cattle. Software (FlySpotter; http://ucanr.org/ sites/FlySpotter/download/) using computer vision technology was developed to count fly spots on a scanned image of a spot card to dramatically reduce time invested in monitoring house flies. Counts provided by the FlySpotter software were highly correlated to visual counts. The use of spot cards for monitoring house flies is recommended for dairy IPM programs.
Biyeyeme Bi Mve, Marie-Jeanne; Cloutier, Yves; Lacombe, Nancy; Lavoie, Jacques; Debia, Maximilien; Marchand, Geneviève
2016-12-01
Heating, ventilation, and air-conditioning (HVAC) systems contain dust that can be contaminated with fungal spores (molds), which may have harmful effects on the respiratory health of the occupants of a building. HVAC cleaning is often based on visual inspection of the quantity of dust, without taking the mold content into account. The purpose of this study is to propose a method to estimate fungal contamination of dust in HVAC systems. Comparisons of different analytical methods were carried out on dust deposited in a controlled-atmosphere exposure chamber. Sixty samples were analyzed using four methods: culture, direct microscopic spore count (DMSC), β-N-acetylhexosaminidase (NAHA) dosing and qPCR. For each method, the limit of detection, replicability, and repeatability were assessed. The Pearson correlation coefficients between the methods were also evaluated. Depending on the analytical method, mean spore concentrations per 100 cm 2 of dust ranged from 10,000 to 682,000. Limits of detection varied from 120 to 217,000 spores/100 cm 2 . Replicability and repeatability were between 1 and 15%. Pearson correlation coefficients varied from -0.217 to 0.83. The 18S qPCR showed the best sensitivity and precision, as well as the best correlation with the culture method. PCR targets only molds, and a total count of fungal DNA is obtained. Among the methods, mold DNA amplification by qPCR is the method suggested for estimating the fungal content found in dust of HVAC systems.
Comparison of methods for estimating density of forest songbirds from point counts
Jennifer L. Reidy; Frank R. Thompson; J. Wesley. Bailey
2011-01-01
New analytical methods have been promoted for estimating the probability of detection and density of birds from count data but few studies have compared these methods using real data. We compared estimates of detection probability and density from distance and time-removal models and survey protocols based on 5- or 10-min counts and outer radii of 50 or 100 m. We...
Understanding poisson regression.
Hayat, Matthew J; Higgins, Melinda
2014-04-01
Nurse investigators often collect study data in the form of counts. Traditional methods of data analysis have historically approached analysis of count data either as if the count data were continuous and normally distributed or with dichotomization of the counts into the categories of occurred or did not occur. These outdated methods for analyzing count data have been replaced with more appropriate statistical methods that make use of the Poisson probability distribution, which is useful for analyzing count data. The purpose of this article is to provide an overview of the Poisson distribution and its use in Poisson regression. Assumption violations for the standard Poisson regression model are addressed with alternative approaches, including addition of an overdispersion parameter or negative binomial regression. An illustrative example is presented with an application from the ENSPIRE study, and regression modeling of comorbidity data is included for illustrative purposes. Copyright 2014, SLACK Incorporated.
Point counts are a common method for sampling avian distribution and abundance. Though methods for estimating detection probabilities are available, many analyses use raw counts and do not correct for detectability. We use a removal model of detection within an N-mixture approa...
Sushames, Ashleigh; Edwards, Andrew; Thompson, Fintan; McDermott, Robyn; Gebel, Klaus
2016-01-01
Objectives To examine the validity and reliability of the Fitbit Flex against direct observation for measuring steps in the laboratory and against the Actigraph for step counts in free-living conditions and for moderate-to-vigorous physical activity (MVPA) and activity energy expenditure (AEE) overall. Methods Twenty-five adults (12 females, 13 males) wore a Fitbit Flex and an Actigraph GT3X+ during a laboratory based protocol (including walking, incline walking, running and stepping) and free-living conditions during a single day period to examine measurement of steps, AEE and MVPA. Twenty-four of the participants attended a second session using the same protocol. Results Intraclass correlations (ICC) for test-retest reliability of the Fitbit Flex were strong for walking (ICC = 0.57), moderate for stair stepping (ICC = 0.34), and weak for incline walking (ICC = 0.22) and jogging (ICC = 0.26). The Fitbit significantly undercounted walking steps in the laboratory (absolute proportional difference: 21.2%, 95%CI 13.0–29.4%), but it was more accurate, despite slightly over counting, for both jogging (6.4%, 95%CI 3.7–9.0%) and stair stepping (15.5%, 95%CI 10.1–20.9%). The Fitbit had higher coefficients of variation (Cv) for step counts compared to direct observation and the Actigraph. In free-living conditions, the average MVPA minutes were lower in the Fitbit (35.4 minutes) compared to the Actigraph (54.6 minutes), but AEE was greater from the Fitbit (808.1 calories) versus the Actigraph (538.9 calories). The coefficients of variation were similar for AEE for the Actigraph (Cv = 36.0) and Fitbit (Cv = 35.0), but lower in the Actigraph (Cv = 25.5) for MVPA against the Fitbit (Cv = 32.7). Conclusion The Fitbit Flex has moderate validity for measuring physical activity relative to direct observation and the Actigraph. Test-rest reliability of the Fitbit was dependant on activity type and had greater variation between sessions compared to the Actigraph. Physical activity surveillance studies using the Fitbit Flex should consider the potential effect of measurement reactivity and undercounting of steps. PMID:27589592
DOE Office of Scientific and Technical Information (OSTI.GOV)
Shrestha, S; Vedantham, S; Karellas, A
Purpose: Detectors with hexagonal pixels require resampling to square pixels for distortion-free display of acquired images. In this work, the presampling modulation transfer function (MTF) of a hexagonal pixel array photon-counting CdTe detector for region-of-interest fluoroscopy was measured and the optimal square pixel size for resampling was determined. Methods: A 0.65mm thick CdTe Schottky sensor capable of concurrently acquiring up to 3 energy-windowed images was operated in a single energy-window mode to include ≥10 KeV photons. The detector had hexagonal pixels with apothem of 30 microns resulting in pixel spacing of 60 and 51.96 microns along the two orthogonal directions.more » Images of a tungsten edge test device acquired under IEC RQA5 conditions were double Hough transformed to identify the edge and numerically differentiated. The presampling MTF was determined from the finely sampled line spread function that accounted for the hexagonal sampling. The optimal square pixel size was determined in two ways; the square pixel size for which the aperture function evaluated at the Nyquist frequencies along the two orthogonal directions matched that from the hexagonal pixel aperture functions, and the square pixel size for which the mean absolute difference between the square and hexagonal aperture functions was minimized over all frequencies up to the Nyquist limit. Results: Evaluation of the aperture functions over the entire frequency range resulted in square pixel size of 53 microns with less than 2% difference from the hexagonal pixel. Evaluation of the aperture functions at Nyquist frequencies alone resulted in 54 microns square pixels. For the photon-counting CdTe detector and after resampling to 53 microns square pixels using quadratic interpolation, the presampling MTF at Nyquist frequency of 9.434 cycles/mm along the two directions were 0.501 and 0.507. Conclusion: Hexagonal pixel array photon-counting CdTe detector after resampling to square pixels provides high-resolution imaging suitable for fluoroscopy.« less
A THUMBNAIL HISTORY OF HETEROTROPHIC PLATE COUNT (HPC) METHODOLOGY IN THE UNITED STATES
Over the past 100 years, the method of determining the number of bacteria in water, foods or other materials has been termed variously as: bacterial plate count, total plate count, total viable plate count, aerobic plate count, standard plate cound and more recently, heterotrophi...
van Sighem, Ard; Sabin, Caroline A.; Phillips, Andrew N.
2015-01-01
Background It is important to have methods available to estimate the number of people who have undiagnosed HIV and are in need of antiretroviral therapy (ART). Methods The method uses the concept that a predictable level of occurrence of AIDS or other HIV-related clinical symptoms which lead to presentation for care, and hence diagnosis of HIV, arises in undiagnosed people with a given CD4 count. The method requires surveillance data on numbers of new HIV diagnoses with HIV-related symptoms, and the CD4 count at diagnosis. The CD4 count-specific rate at which HIV-related symptoms develop are estimated from cohort data. 95% confidence intervals can be constructed using a simple simulation method. Results For example, if there were 13 HIV diagnoses with HIV-related symptoms made in one year with CD4 count at diagnosis between 150–199 cells/mm3, then since the CD4 count-specific rate of HIV-related symptoms is estimated as 0.216 per person-year, the estimated number of person years lived in people with undiagnosed HIV with CD4 count 150–199 cells/mm3 is 13/0.216 = 60 (95% confidence interval: 29–100), which is considered an estimate of the number of people living with undiagnosed HIV in this CD4 count stratum. Conclusions The method is straightforward to implement within a short period once a surveillance system of all new HIV diagnoses, collecting data on HIV-related symptoms at diagnosis, is in place and is most suitable for estimating the number of undiagnosed people with CD4 count <200 cells/mm3 due to the low rate of developing HIV-related symptoms at higher CD4 counts. A potential source of bias is under-diagnosis and under-reporting of diagnoses with HIV-related symptoms. Although this method has limitations as with all approaches, it is important for prompting increased efforts to identify undiagnosed people, particularly those with low CD4 count, and for informing levels of unmet need for ART. PMID:25768925
Shrestha, Suman; Karellas, Andrew; Shi, Linxi; Gounis, Matthew J.; Bellazzini, Ronaldo; Spandre, Gloria; Brez, Alessandro; Minuti, Massimo
2016-01-01
Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixel pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications. PMID:27147324
Smartphone and GPS technology for free-roaming dog population surveillance - a methodological study.
Barnard, Shanis; Ippoliti, Carla; Di Flaviano, Daniele; De Ruvo, Andrea; Messori, Stefano; Giovannini, Armando; Dalla Villa, Paolo
2015-01-01
Free-roaming dogs (FRD) represent a potential threat to the quality of life in cities from an ecological, social and public health point of view. One of the most urgent concerns is the role of uncontrolled dogs as reservoirs of infectious diseases transmittable to humans and, above all, rabies. An estimate of the FRD population size and characteristics in a given area is the first step for any relevant intervention programme. Direct count methods are still prominent because of their non-invasive approach, information technologies can support such methods facilitating data collection and allowing for a more efficient data handling. This paper presents a new framework for data collection using a topological algorithm implemented as ArcScript in ESRI® ArcGIS software, which allows for a random selection of the sampling areas. It also supplies a mobile phone application for Android® operating system devices which integrates Global Positioning System (GPS) and Google MapsTM. The potential of such a framework was tested in 2 Italian regions. Coupling technological and innovative solutions associated with common counting methods facilitate data collection and transcription. It also paves the way to future applications, which could support dog population management systems.
Li, Chunmei; Yu, Zhilong; Fu, Yusi; Pang, Yuhong; Huang, Yanyi
2017-04-26
We develop a novel single-cell-based platform through digital counting of amplified genomic DNA fragments, named multifraction amplification (mfA), to detect the copy number variations (CNVs) in a single cell. Amplification is required to acquire genomic information from a single cell, while introducing unavoidable bias. Unlike prevalent methods that directly infer CNV profiles from the pattern of sequencing depth, our mfA platform denatures and separates the DNA molecules from a single cell into multiple fractions of a reaction mix before amplification. By examining the sequencing result of each fraction for a specific fragment and applying a segment-merge maximum likelihood algorithm to the calculation of copy number, we digitize the sequencing-depth-based CNV identification and thus provide a method that is less sensitive to the amplification bias. In this paper, we demonstrate a mfA platform through multiple displacement amplification (MDA) chemistry. When performing the mfA platform, the noise of MDA is reduced; therefore, the resolution of single-cell CNV identification can be improved to 100 kb. We can also determine the genomic region free of allelic drop-out with mfA platform, which is impossible for conventional single-cell amplification methods.
Code of Federal Regulations, 2010 CFR
2010-10-01
... three activities may also count as participation: job skills training directly related to employment... study leading to a certificate of general equivalence. (d)(1) We will deem a work-eligible individual...
A Method for Counting Moving People in Video Surveillance Videos
NASA Astrophysics Data System (ADS)
Conte, Donatello; Foggia, Pasquale; Percannella, Gennaro; Tufano, Francesco; Vento, Mario
2010-12-01
People counting is an important problem in video surveillance applications. This problem has been faced either by trying to detect people in the scene and then counting them or by establishing a mapping between some scene feature and the number of people (avoiding the complex detection problem). This paper presents a novel method, following this second approach, that is based on the use of SURF features and of an [InlineEquation not available: see fulltext.]-SVR regressor provide an estimate of this count. The algorithm takes specifically into account problems due to partial occlusions and to perspective. In the experimental evaluation, the proposed method has been compared with the algorithm by Albiol et al., winner of the PETS 2009 contest on people counting, using the same PETS 2009 database. The provided results confirm that the proposed method yields an improved accuracy, while retaining the robustness of Albiol's algorithm.
NASA Astrophysics Data System (ADS)
Zhang, Guoqing; Lina, Liu
2018-02-01
An ultra-fast photon counting method is proposed based on the charge integration of output electrical pulses of passive quenching silicon photomultipliers (SiPMs). The results of the numerical analysis with actual parameters of SiPMs show that the maximum photon counting rate of a state-of-art passive quenching SiPM can reach ~THz levels which is much larger than that of the existing photon counting devices. The experimental procedure is proposed based on this method. This photon counting regime of SiPMs is promising in many fields such as large dynamic light power detection.
Villagrán, E; Linossier, A; Donoso, E
1999-02-01
Salivary Streptococci mutans contamination is considered the main microbiological risk factor for the initiation of caries. To assess the oral health of pregnant women, counting Salivary Streptococci mutants. One hundred seventy four pregnant women, in the first, second and third trimester of pregnancy, aged 27 +/- 5 years old, consulting at a public primary health center, were studied. Puerperal women that had their delivery two months before, were studied as a control group. Salivary samples were obtained and Streptococci mutans colonies were counted using quantitative and semiquantitative methods. There was a good concordance between both counting methods. No differences in Streptococci mutans counts were observed among the three groups of pregnant women, but the latter as a group had higher counts than puerperal women. Women with more than 5 caries had also higher counts. Semiquantitative Streptococci mutans counts are easy, rapid and non invasive and have a good concordance with quantitative counts in saliva.
Lepez, Trees; Vandewoestyne, Mado; Van Hoofstat, David; Deforce, Dieter
2014-11-01
The success rate of STR profiling of hairs found at a crime scene is quite low and negative results of hair analysis are frequently reported. To increase the success rate of DNA analysis of hairs in forensics, nuclei in hair roots can be counted after staining the hair root with DAPI. Two staining methods were tested: a longer method with two 1h incubations in respectively a DAPI- and a wash-solution, and a fast, direct staining of the hair root on microscope slides. The two staining methods were not significantly different. The results of the STR analysis for both procedures showed that 20 nuclei are necessary to obtain at least partial STR profiles. When more than 50 nuclei were counted, full STR profiles were always obtained. In 96% of the cases where no nuclei were detected, no STR profile could be obtained. However, 4% of the DAPI-negative hair roots resulted in at least partial STR profiles. Therefore, each forensic case has to be evaluated separately in function of the importance of the evidential value of the found hair. The fast staining method was applied in 36 forensic cases on 279 hairs in total. A fast screening method using DAPI can be used to increase the success rate of hair analysis in forensics. Copyright © 2014 The Authors. Published by Elsevier Ireland Ltd.. All rights reserved.
NASA Astrophysics Data System (ADS)
Weber, M. E.; Reichelt, L.; Kuhn, G.; Pfeiffer, M.; Korff, B.; Thurow, J.; Ricken, W.
2010-03-01
We present tools for rapid and quantitative detection of sediment lamination. The BMPix tool extracts color and gray scale curves from images at pixel resolution. The PEAK tool uses the gray scale curve and performs, for the first time, fully automated counting of laminae based on three methods. The maximum count algorithm counts every bright peak of a couplet of two laminae (annual resolution) in a smoothed curve. The zero-crossing algorithm counts every positive and negative halfway passage of the curve through a wide moving average, separating the record into bright and dark intervals (seasonal resolution). The same is true for the frequency truncation method, which uses Fourier transformation to decompose the curve into its frequency components before counting positive and negative passages. The algorithms are available at doi:10.1594/PANGAEA.729700. We applied the new methods successfully to tree rings, to well-dated and already manually counted marine varves from Saanich Inlet, and to marine laminae from the Antarctic continental margin. In combination with AMS14C dating, we found convincing evidence that laminations in Weddell Sea sites represent varves, deposited continuously over several millennia during the last glacial maximum. The new tools offer several advantages over previous methods. The counting procedures are based on a moving average generated from gray scale curves instead of manual counting. Hence, results are highly objective and rely on reproducible mathematical criteria. Also, the PEAK tool measures the thickness of each year or season. Since all information required is displayed graphically, interactive optimization of the counting algorithms can be achieved quickly and conveniently.
Effect of distance-related heterogeneity on population size estimates from point counts
Efford, Murray G.; Dawson, Deanna K.
2009-01-01
Point counts are used widely to index bird populations. Variation in the proportion of birds counted is a known source of error, and for robust inference it has been advocated that counts be converted to estimates of absolute population size. We used simulation to assess nine methods for the conduct and analysis of point counts when the data included distance-related heterogeneity of individual detection probability. Distance from the observer is a ubiquitous source of heterogeneity, because nearby birds are more easily detected than distant ones. Several recent methods (dependent double-observer, time of first detection, time of detection, independent multiple-observer, and repeated counts) do not account for distance-related heterogeneity, at least in their simpler forms. We assessed bias in estimates of population size by simulating counts with fixed radius w over four time intervals (occasions). Detection probability per occasion was modeled as a half-normal function of distance with scale parameter sigma and intercept g(0) = 1.0. Bias varied with sigma/w; values of sigma inferred from published studies were often 50% for a 100-m fixed-radius count. More critically, the bias of adjusted counts sometimes varied more than that of unadjusted counts, and inference from adjusted counts would be less robust. The problem was not solved by using mixture models or including distance as a covariate. Conventional distance sampling performed well in simulations, but its assumptions are difficult to meet in the field. We conclude that no existing method allows effective estimation of population size from point counts.
Park, Junghyun; Kim, Myunghee
2013-01-01
This study was performed to compare the performance of Sanita-Kun dry medium culture plate with those of traditional culture medium and Petrifilm dry medium culture plate for the enumeration of the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet. Mesophilic aerobic bacteria were comparatively evaluated in milk, ice cream, ham, and codfish fillet using Sanita-Kun aerobic count (SAC), Petrifilm aerobic count (PAC), and traditional plate count agar (PCA) media. According to the results, all methods showed high correlations of 0.989~1.000 and no significant differences were observed for enumerating the mesophilic aerobic bacteria in the tested food products. SAC method was easier to perform and count colonies efficiently as compared to the PCA and PAC methods. Therefore, we concluded that the SAC method offers an acceptable alternative to the PCA and PAC methods for counting the mesophilic aerobic bacteria in milk, ice cream, ham, and codfish fillet products. PMID:24551829
Multiplexed Detection of Cytokines Based on Dual Bar-Code Strategy and Single-Molecule Counting.
Li, Wei; Jiang, Wei; Dai, Shuang; Wang, Lei
2016-02-02
Cytokines play important roles in the immune system and have been regarded as biomarkers. While single cytokine is not specific and accurate enough to meet the strict diagnosis in practice, in this work, we constructed a multiplexed detection method for cytokines based on dual bar-code strategy and single-molecule counting. Taking interferon-γ (IFN-γ) and tumor necrosis factor-α (TNF-α) as model analytes, first, the magnetic nanobead was functionalized with the second antibody and primary bar-code strands, forming a magnetic nanoprobe. Then, through the specific reaction of the second antibody and the antigen that fixed by the primary antibody, sandwich-type immunocomplex was formed on the substrate. Next, the primary bar-code strands as amplification units triggered multibranched hybridization chain reaction (mHCR), producing nicked double-stranded polymers with multiple branched arms, which were served as secondary bar-code strands. Finally, the secondary bar-code strands hybridized with the multimolecule labeled fluorescence probes, generating enhanced fluorescence signals. The numbers of fluorescence dots were counted one by one for quantification with epi-fluorescence microscope. By integrating the primary and secondary bar-code-based amplification strategy and the multimolecule labeled fluorescence probes, this method displayed an excellent sensitivity with the detection limits were both 5 fM. Unlike the typical bar-code assay that the bar-code strands should be released and identified on a microarray, this method is more direct. Moreover, because of the selective immune reaction and the dual bar-code mechanism, the resulting method could detect the two targets simultaneously. Multiple analysis in human serum was also performed, suggesting that our strategy was reliable and had a great potential application in early clinical diagnosis.
Battaile, Brian; Jay, Chadwick V.; Udevitz, Mark S.; Fischbach, Anthony S.
2017-01-01
Increased periods of sparse sea ice over the continental shelf of the Chukchi Sea in late summer have reduced offshore haulout habitat for Pacific walruses (Odobenus rosmarus divergens) and increased opportunities for human activities in the region. Knowing how many walruses could be affected by human activities would be useful to conservation decisions. Currently, there are no adequate estimates of walrus abundance in the northeastern Chukchi Sea during summer–early autumn. Estimating abundance in autumn might be possible from coastal surveys of hauled out walruses during periods when offshore sea ice is unavailable to walruses. We evaluated methods to estimate the size of the walrus population that was using a haulout on the coast of northwestern Alaska in autumn by using aerial photography to count the number of hauled out walruses (herd size) and data from 37 tagged walruses to estimate availability (proportion of population hauled out). We used two methods to estimate availability, direct proportions of hauled out tagged walruses and smoothed proportions using local polynomial regression. Point estimates of herd size (4200–38,000 walruses) and total population size (76,000–287,000 walruses) ranged widely among days and between the two methods of estimating availability. Estimates of population size were influenced most by variation in estimates of availability. Coastal surveys might be improved most by counting walruses when the greatest numbers are hauled out, thereby reducing the influence of availability on population size estimates. The chance of collecting data during peak haulout periods would be improved by conducting multiple surveys.
NASA Astrophysics Data System (ADS)
Liu, Xuejin; Chen, Han; Bornefalk, Hans; Danielsson, Mats; Karlsson, Staffan; Persson, Mats; Xu, Cheng; Huber, Ben
2015-02-01
The variation among energy thresholds in a multibin detector for photon-counting spectral CT can lead to ring artefacts in the reconstructed images. Calibration of the energy thresholds can be used to achieve homogeneous threshold settings or to develop compensation methods to reduce the artefacts. We have developed an energy-calibration method for the different comparator thresholds employed in a photon-counting silicon-strip detector. In our case, this corresponds to specifying the linear relation between the threshold positions in units of mV and the actual deposited photon energies in units of keV. This relation is determined by gain and offset values that differ for different detector channels due to variations in the manufacturing process. Typically, the calibration is accomplished by correlating the peak positions of obtained pulse-height spectra to known photon energies, e.g. with the aid of mono-energetic x rays from synchrotron radiation, radioactive isotopes or fluorescence materials. Instead of mono-energetic x rays, the calibration method presented in this paper makes use of a broad x-ray spectrum provided by commercial x-ray tubes. Gain and offset as the calibration parameters are obtained by a regression analysis that adjusts a simulated spectrum of deposited energies to a measured pulse-height spectrum. Besides the basic photon interactions such as Rayleigh scattering, Compton scattering and photo-electric absorption, the simulation takes into account the effect of pulse pileup, charge sharing and the electronic noise of the detector channels. We verify the method for different detector channels with the aid of a table-top setup, where we find the uncertainty of the keV-value of a calibrated threshold to be between 0.1 and 0.2 keV.
Baudart, Julia; Coallier, Josée; Laurent, Patrick; Prévost, Michèle
2002-01-01
Water quality assessment involves the specific, sensitive, and rapid detection of bacterial indicators and pathogens in water samples, including viable but nonculturable (VBNC) cells. This work evaluates the specificity and sensitivity of a new method which combines a fluorescent in situ hybridization (FISH) approach with a physiological assay (direct viable count [DVC]) for the direct enumeration, at the single-cell level, of highly diluted viable cells of members of the family Enterobacteriaceae in freshwater and drinking water after membrane filtration. The approach (DVC-FISH) uses a new direct detection device, the laser scanning cytometer (Scan RDI). Combining the DVC-FISH method on a membrane with Scan RDI detection makes it possible to detect as few as one targeted cell in approximately 108 nontargeted cells spread over the membrane. The ability of this new approach to detect and enumerate VBNC enterobacterial cells in freshwater and drinking water distribution systems was investigated and is discussed. PMID:12324357
NASA Astrophysics Data System (ADS)
Wang, Xin; Zhang, Yanqi; Zhang, Limin; Li, Jiao; Zhou, Zhongxing; Zhao, Huijuan; Gao, Feng
2016-04-01
We present a generalized strategy for direct reconstruction in pharmacokinetic diffuse fluorescence tomography (DFT) with CT-analogous scanning mode, which can accomplish one-step reconstruction of the indocyanine-green pharmacokinetic-rate images within in vivo small animals by incorporating the compartmental kinetic model into an adaptive extended Kalman filtering scheme and using an instantaneous sampling dataset. This scheme, compared with the established indirect and direct methods, eliminates the interim error of the DFT inversion and relaxes the expensive requirement of the instrument for obtaining highly time-resolved date-sets of complete 360 deg projections. The scheme is validated by two-dimensional simulations for the two-compartment model and pilot phantom experiments for the one-compartment model, suggesting that the proposed method can estimate the compartmental concentrations and the pharmacokinetic-rates simultaneously with a fair quantitative and localization accuracy, and is well suitable for cost-effective and dense-sampling instrumentation based on the highly-sensitive photon counting technique.
Colonisation of soilless growing media for tomato by Trichoderma harzianum.
De Schutter, B; Aerts, R; Rombouts, L
2001-01-01
An experiment was conducted to evaluate the distribution of T. harzianum in soilless media used in greenhouse growing systems for tomatoes. Growing media based on rockwool and based on coconut fibre were included. The fungus was applied to the roots of the plant by means of a conidial suspension. The upper plant parts were removed from the coconut fibre an the rockwool slab after 10 and 15 weeks respectively. Both the coconut fibre and the rockwool slab were divided into fragments with a width of 10 cm. The coconut fibre medium fragments were again divided in an upper and a lower part. For every fragment the CFU/g was determined by two different methods. In the first method a known volume of growing medium was brought into suspension using a blender and diluted. Appropriate dilutions were plated on a selective medium. In the second method a known volume of growing medium was spread directly upon a selective medium in petri dishes. All dishes were incubated at room temperature and colonies were counted. Results showed that in the case of the coconut fibre growing medium T. harzianum was isolated in every fragment of the substrate. Highest densities were measured at the site of inoculation. In the lower part of the fragments less CFU/g were counted than in the upper part. In the case of the rockwool growing medium, there were several fragments in which no T. harzianum was isolated. The dilution technique demonstrated to be most useful in cases of high density. The direct spreading-method is best applied when low densities are expected. These observations demonstrate that the growing medium based upon coconut fibre is more appropriate for colonisation by T. harzianum. However, densities are higher at the site of inoculation in both tested growing media.
Bui, H N; Bogers, J P A M; Cohen, D; Njo, T; Herruer, M H
2016-12-01
We evaluated the performance of the HemoCue WBC DIFF, a point-of-care device for total and differential white cell count, primarily to test its suitability for the mandatory white blood cell monitoring in clozapine use. Leukocyte count and 5-part differentiation was performed by the point-of-care device and by routine laboratory method in venous EDTA-blood samples from 20 clozapine users, 20 neutropenic patients, and 20 healthy volunteers. From the volunteers, also a capillary sample was drawn. Intra-assay reproducibility and drop-to-drop variation were tested. The correlation between both methods in venous samples was r > 0.95 for leukocyte, neutrophil, and lymphocyte counts. The correlation between point-of-care (capillary sample) and routine (venous sample) methods for these cells was 0.772; 0.817 and 0.798, respectively. Only for leukocyte and neutrophil counts, the intra-assay reproducibility was sufficient. The point-of-care device can be used to screen for leukocyte and neutrophil counts. Because of the relatively high measurement uncertainty and poor correlation with venous samples, we recommend to repeat the measurement with a venous sample if cell counts are in the lower reference range. In case of clozapine therapy, neutropenia can probably be excluded if high neutrophil counts are found and patients can continue their therapy. © 2016 John Wiley & Sons Ltd.
Survey of predators and sampling method comparison in sweet corn.
Musser, Fred R; Nyrop, Jan P; Shelton, Anthony M
2004-02-01
Natural predation is an important component of integrated pest management that is often overlooked because it is difficult to quantify and perceived to be unreliable. To begin incorporating natural predation into sweet corn, Zea mays L., pest management, a predator survey was conducted and then three sampling methods were compared for their ability to accurately monitor the most abundant predators. A predator survey on sweet corn foliage in New York between 1999 and 2001 identified 13 species. Orius insidiosus (Say), Coleomegilla maculata (De Geer), and Harmonia axyridis (Pallas) were the most numerous predators in all years. To determine the best method for sampling adult and immature stages of these predators, comparisons were made among nondestructive field counts, destructive counts, and yellow sticky cards. Field counts were correlated with destructive counts for all populations, but field counts of small insects were biased. Sticky cards underrepresented immature populations. Yellow sticky cards were more attractive to C. maculata adults than H. axyridis adults, especially before pollen shed, making coccinellid population estimates based on sticky cards unreliable. Field counts were the most precise method for monitoring adult and immature stages of the three major predators. Future research on predicting predation of pests in sweet corn should be based on field counts of predators because these counts are accurate, have no associated supply costs, and can be made quickly.
Estimating consumer familiarity with health terminology: a context-based approach.
Zeng-Treitler, Qing; Goryachev, Sergey; Tse, Tony; Keselman, Alla; Boxwala, Aziz
2008-01-01
Effective health communication is often hindered by a "vocabulary gap" between language familiar to consumers and jargon used in medical practice and research. To present health information to consumers in a comprehensible fashion, we need to develop a mechanism to quantify health terms as being more likely or less likely to be understood by typical members of the lay public. Prior research has used approaches including syllable count, easy word list, and frequency count, all of which have significant limitations. In this article, we present a new method that predicts consumer familiarity using contextual information. The method was applied to a large query log data set and validated using results from two previously conducted consumer surveys. We measured the correlation between the survey result and the context-based prediction, syllable count, frequency count, and log normalized frequency count. The correlation coefficient between the context-based prediction and the survey result was 0.773 (p < 0.001), which was higher than the correlation coefficients between the survey result and the syllable count, frequency count, and log normalized frequency count (p < or = 0.012). The context-based approach provides a good alternative to the existing term familiarity assessment methods.
A Vision-Based Counting and Recognition System for Flying Insects in Intelligent Agriculture.
Zhong, Yuanhong; Gao, Junyuan; Lei, Qilun; Zhou, Yao
2018-05-09
Rapid and accurate counting and recognition of flying insects are of great importance, especially for pest control. Traditional manual identification and counting of flying insects is labor intensive and inefficient. In this study, a vision-based counting and classification system for flying insects is designed and implemented. The system is constructed as follows: firstly, a yellow sticky trap is installed in the surveillance area to trap flying insects and a camera is set up to collect real-time images. Then the detection and coarse counting method based on You Only Look Once (YOLO) object detection, the classification method and fine counting based on Support Vector Machines (SVM) using global features are designed. Finally, the insect counting and recognition system is implemented on Raspberry PI. Six species of flying insects including bee, fly, mosquito, moth, chafer and fruit fly are selected to assess the effectiveness of the system. Compared with the conventional methods, the test results show promising performance. The average counting accuracy is 92.50% and average classifying accuracy is 90.18% on Raspberry PI. The proposed system is easy-to-use and provides efficient and accurate recognition data, therefore, it can be used for intelligent agriculture applications.
A Vision-Based Counting and Recognition System for Flying Insects in Intelligent Agriculture
Zhong, Yuanhong; Gao, Junyuan; Lei, Qilun; Zhou, Yao
2018-01-01
Rapid and accurate counting and recognition of flying insects are of great importance, especially for pest control. Traditional manual identification and counting of flying insects is labor intensive and inefficient. In this study, a vision-based counting and classification system for flying insects is designed and implemented. The system is constructed as follows: firstly, a yellow sticky trap is installed in the surveillance area to trap flying insects and a camera is set up to collect real-time images. Then the detection and coarse counting method based on You Only Look Once (YOLO) object detection, the classification method and fine counting based on Support Vector Machines (SVM) using global features are designed. Finally, the insect counting and recognition system is implemented on Raspberry PI. Six species of flying insects including bee, fly, mosquito, moth, chafer and fruit fly are selected to assess the effectiveness of the system. Compared with the conventional methods, the test results show promising performance. The average counting accuracy is 92.50% and average classifying accuracy is 90.18% on Raspberry PI. The proposed system is easy-to-use and provides efficient and accurate recognition data, therefore, it can be used for intelligent agriculture applications. PMID:29747429
[Development and prospect on skeletal age evaluation methods of X-ray film].
Wang, Ya-hui; Zhu, Guang-you; Qiao, Ke; Bian, Shi-zhong; Fan, Li-hua; Cheng, Yi-bin; Ying, Chong-liang; Shen, Yan
2007-10-01
The traditional methods of skeletal age estimation mainly include Numeration, Atlas, and Counting scores. In recent years, other new methods were proposed by several scholars. Utilizing image logical characteristics of X-ray film to extrapolate skeletal age is a key means by present forensic medicine workers in evaluating skeletal age. However, there exist some variations when we present the conclusion of skeletal age as an "evidence" directly to the Justice Trial Authority. In order to enhance the accuracy of skeletal age determination, further investigation for appropriate methodology should be undertaken. After a collective study of pertinent domestic and international literatures, we present this review of the research and advancement on skeletal age evaluation methods of X-ray film.
Better Than Counting: Density Profiles from Force Sampling
NASA Astrophysics Data System (ADS)
de las Heras, Daniel; Schmidt, Matthias
2018-05-01
Calculating one-body density profiles in equilibrium via particle-based simulation methods involves counting of events of particle occurrences at (histogram-resolved) space points. Here, we investigate an alternative method based on a histogram of the local force density. Via an exact sum rule, the density profile is obtained with a simple spatial integration. The method circumvents the inherent ideal gas fluctuations. We have tested the method in Monte Carlo, Brownian dynamics, and molecular dynamics simulations. The results carry a statistical uncertainty smaller than that of the standard counting method, reducing therefore the computation time.
Learning to Count: School Finance Formula Count Methods and Attendance-Related Student Outcomes
ERIC Educational Resources Information Center
Ely, Todd L.; Fermanich, Mark L.
2013-01-01
School systems are under increasing pressure to improve student performance. Several states have recently explored adopting student count methods for school funding purposes that incentivize school attendance and continuous enrollment by adjusting funding for changes in enrollment or attendance over the course of the school year. However, no…
We examined the effects of using a fixed-count subsample of 300 organisms on metric values using macroinvertebrate samples collected with 3 field sampling methods at 12 boatable river sites. For each sample, we used metrics to compare an initial fixed-count subsample of approxima...
Cai, Qing; Abdel-Aty, Mohamed; Lee, Jaeyoung
2017-10-01
This study aims at contributing to the literature on pedestrian and bicyclist safety by building on the conventional count regression models to explore exogenous factors affecting pedestrian and bicyclist crashes at the macroscopic level. In the traditional count models, effects of exogenous factors on non-motorist crashes were investigated directly. However, the vulnerable road users' crashes are collisions between vehicles and non-motorists. Thus, the exogenous factors can affect the non-motorist crashes through the non-motorists and vehicle drivers. To accommodate for the potentially different impact of exogenous factors we convert the non-motorist crash counts as the product of total crash counts and proportion of non-motorist crashes and formulate a joint model of the negative binomial (NB) model and the logit model to deal with the two parts, respectively. The formulated joint model is estimated using non-motorist crash data based on the Traffic Analysis Districts (TADs) in Florida. Meanwhile, the traditional NB model is also estimated and compared with the joint model. The result indicates that the joint model provides better data fit and can identify more significant variables. Subsequently, a novel joint screening method is suggested based on the proposed model to identify hot zones for non-motorist crashes. The hot zones of non-motorist crashes are identified and divided into three types: hot zones with more dangerous driving environment only, hot zones with more hazardous walking and cycling conditions only, and hot zones with both. It is expected that the joint model and screening method can help decision makers, transportation officials, and community planners to make more efficient treatments to proactively improve pedestrian and bicyclist safety. Published by Elsevier Ltd.
A Maximum Entropy Test for Evaluating Higher-Order Correlations in Spike Counts
Onken, Arno; Dragoi, Valentin; Obermayer, Klaus
2012-01-01
Evaluating the importance of higher-order correlations of neural spike counts has been notoriously hard. A large number of samples are typically required in order to estimate higher-order correlations and resulting information theoretic quantities. In typical electrophysiology data sets with many experimental conditions, however, the number of samples in each condition is rather small. Here we describe a method that allows to quantify evidence for higher-order correlations in exactly these cases. We construct a family of reference distributions: maximum entropy distributions, which are constrained only by marginals and by linear correlations as quantified by the Pearson correlation coefficient. We devise a Monte Carlo goodness-of-fit test, which tests - for a given divergence measure of interest - whether the experimental data lead to the rejection of the null hypothesis that it was generated by one of the reference distributions. Applying our test to artificial data shows that the effects of higher-order correlations on these divergence measures can be detected even when the number of samples is small. Subsequently, we apply our method to spike count data which were recorded with multielectrode arrays from the primary visual cortex of anesthetized cat during an adaptation experiment. Using mutual information as a divergence measure we find that there are spike count bin sizes at which the maximum entropy hypothesis can be rejected for a substantial number of neuronal pairs. These results demonstrate that higher-order correlations can matter when estimating information theoretic quantities in V1. They also show that our test is able to detect their presence in typical in-vivo data sets, where the number of samples is too small to estimate higher-order correlations directly. PMID:22685392
Radionuclide counting technique for measuring wind velocity and direction
NASA Technical Reports Server (NTRS)
Singh, J. J. (Inventor)
1984-01-01
An anemometer utilizing a radionuclide counting technique for measuring both the velocity and the direction of wind is described. A pendulum consisting of a wire and a ball with a source of radiation on the lower surface of the ball is positioned by the wind. Detectors and are located in a plane perpendicular to pendulum (no wind). The detectors are located on the circumferene of a circle and are equidistant from each other as well as the undisturbed (no wind) source ball position.
Inverting ion images without Abel inversion: maximum entropy reconstruction of velocity maps.
Dick, Bernhard
2014-01-14
A new method for the reconstruction of velocity maps from ion images is presented, which is based on the maximum entropy concept. In contrast to other methods used for Abel inversion the new method never applies an inversion or smoothing to the data. Instead, it iteratively finds the map which is the most likely cause for the observed data, using the correct likelihood criterion for data sampled from a Poissonian distribution. The entropy criterion minimizes the information content in this map, which hence contains no information for which there is no evidence in the data. Two implementations are proposed, and their performance is demonstrated with simulated and experimental data: Maximum Entropy Velocity Image Reconstruction (MEVIR) obtains a two-dimensional slice through the velocity distribution and can be compared directly to Abel inversion. Maximum Entropy Velocity Legendre Reconstruction (MEVELER) finds one-dimensional distribution functions Q(l)(v) in an expansion of the velocity distribution in Legendre polynomials P((cos θ) for the angular dependence. Both MEVIR and MEVELER can be used for the analysis of ion images with intensities as low as 0.01 counts per pixel, with MEVELER performing significantly better than MEVIR for images with low intensity. Both methods perform better than pBASEX, in particular for images with less than one average count per pixel.
Primary Standardization of 152Eu by 4πβ(LS) – γ (Nal) coincidence counting and CIEMAT-NIST method
NASA Astrophysics Data System (ADS)
Ruzzarin, A.; da Cruz, P. A. L.; Ferreira Filho, A. L.; Iwahara, A.
2018-03-01
The 4πβ-γ coincidence counting and CIEMAT/NIST liquid scintillation method were used in the standardization of a solution of 152Eu. In CIEMAT/NIST method, measurements were performed in a Liquid Scintillation Counter model Wallac 1414. In the 4πβ-γ coincidence counting, the solution was standardized using a coincidence method with ‘‘beta-efficiency extrapolation”. A simple 4πβ-γ coincidence system was used, with acrylic scintillation cell coupled to two coincident photomultipliers at 180° each other and NaI(Tl) detector. The activity concentrations obtained were 156.934 ± 0.722 and 157.403 ± 0.113 kBq/g, respectively, for CIEMAT/NIST and 4πβ-γ coincidence counting measurement methods.
Experimental Study for Automatic Colony Counting System Based Onimage Processing
NASA Astrophysics Data System (ADS)
Fang, Junlong; Li, Wenzhe; Wang, Guoxin
Colony counting in many colony experiments is detected by manual method at present, therefore it is difficult for man to execute the method quickly and accurately .A new automatic colony counting system was developed. Making use of image-processing technology, a study was made on the feasibility of distinguishing objectively white bacterial colonies from clear plates according to the RGB color theory. An optimal chromatic value was obtained based upon a lot of experiments on the distribution of the chromatic value. It has been proved that the method greatly improves the accuracy and efficiency of the colony counting and the counting result is not affected by using inoculation, shape or size of the colony. It is revealed that automatic detection of colony quantity using image-processing technology could be an effective way.
NASA Astrophysics Data System (ADS)
Vereecken, Luc; Peeters, Jozef
2003-09-01
The rigorous implementation of transition state theory (TST) for a reaction system with multiple reactant rotamers and multiple transition state conformers is discussed by way of a statistical rate analysis of the 1,5-H-shift in 1-butoxy radicals, a prototype reaction for the important class of H-shift reactions in atmospheric chemistry. Several approaches for deriving a multirotamer TST expression are treated: oscillator versus (hindered) internal rotor models; distinguishable versus indistinguishable atoms; and direct count methods versus degeneracy factors calculated by (simplified) direct count methods or from symmetry numbers and number of enantiomers, where applicable. It is shown that the various treatments are fully consistent, even if the TST expressions themselves appear different. The 1-butoxy H-shift reaction is characterized quantum chemically using B3LYP-DFT; the performance of this level of theory is compared to other methods. Rigorous application of the multirotamer TST methodology in an harmonic oscillator approximation based on this data yields a rate coefficient of k(298 K,1 atm)=1.4×105 s-1, and an Arrhenius expression k(T,1 atm)=1.43×1011 exp(-8.17 kcal mol-1/RT) s-1, which both closely match the experimental recommendations in the literature. The T-dependence is substantially influenced by the multirotamer treatment, as well as by the tunneling and fall-off corrections. The present results are compared to those of simplified TST calculations based solely on the properties of the lowest energy 1-butoxy rotamer.
Spacecraft with gradual acceleration of solar panels
NASA Technical Reports Server (NTRS)
Merhav, Tamir R. (Inventor); Festa, Michael T. (Inventor); Stetson, Jr., John B. (Inventor)
1996-01-01
A spacecraft (8) includes a movable appendage such as solar panels (12) operated by a stepping motor (28) driven by pulses (311). In order to reduce vibration andor attitude error, the drive pulses are generated by a clock down-counter (312) with variable count ratio. Predetermined desired clock ratios are stored in selectable memories (314a-d), and the selected ratio (R) is coupled to a comparator (330) together with the current ratio (C). An up-down counter (340) establishes the current count-down ratio by counting toward the desired ratio under the control of the comparator; thus, a step change of solar panel speed never occurs. When a direction change is commanded, a flag signal generator (350) disables the selectable memories, and enables a further store (360), which generates a count ratio representing a very slow solar panel rotational rate, so that the rotational rate always slows to a low value before direction is changed. The principles of the invention are applicable to any movable appendage.
Recent trends in counts of migrant hawks from northeastern North America
Titus, K.; Fuller, M.R.
1990-01-01
Using simple regression, pooled-sites route-regression, and nonparametric rank-trend analyses, we evaluated trends in counts of hawks migrating past 6 eastern hawk lookouts from 1972 to 1987. The indexing variable was the total count for a season. Bald eagle (Haliaeetus leucocephalus), peregrine falcon (Falco peregrinus), merlin (F. columbarius), osprey (Pandion haliaetus), and Cooper's hawk (Accipiter cooperii) counts increased using route-regression and nonparametric methods (P 0.10). We found no consistent trends (P > 0.10) in counts of sharp-shinned hawks (A. striatus), northern goshawks (A. gentilis) red-shouldered hawks (Buteo lineatus), red-tailed hawks (B. jamaicensis), rough-legged hawsk (B. lagopus), and American kestrels (F. sparverius). Broad-winged hawk (B. platypterus) counts declined (P < 0.05) based on the route-regression method. Empirical comparisons of our results with those for well-studied species such as the peregrine falcon, bald eagle, and osprey indicated agreement with nesting surveys. We suggest that counts of migrant hawks are a useful and economical method for detecting long-term trends in species across regions, particularly for species that otherwise cannot be easily surveyed.
Far-Ultraviolet Number Counts of Field Galaxies
NASA Technical Reports Server (NTRS)
Voyer, Elysse N.; Gardner, Jonathan P.; Teplitz, Harry I.; Siana, Brian D.; deMello, Duilia F.
2010-01-01
The Number counts of far-ultraviolet (FUV) galaxies as a function of magnitude provide a direct statistical measure of the density and evolution of star-forming galaxies. We report on the results of measurements of the rest-frame FUV number counts computed from data of several fields including the Hubble Ultra Deep Field, the Hubble Deep Field North, and the GOODS-North and -South fields. These data were obtained from the Hubble Space Telescope Solar Blind Channel of the Advance Camera for Surveys. The number counts cover an AB magnitude range from 20-29 magnitudes, covering a total area of 15.9 arcmin'. We show that the number counts are lower than those in previous studies using smaller areas. The differences in the counts are likely the result of cosmic variance; our new data cover more area and more lines of sight than the previous studies. The slope of our number counts connects well with local FUV counts and they show good agreement with recent semi-analytical models based on dark matter "merger trees".
Dating Tectonic Activity on Mercury’s Large-Scale Lobate-Scarp Thrust Faults
NASA Astrophysics Data System (ADS)
Barlow, Nadine G.; E Banks, Maria
2017-10-01
Mercury’s widespread large-scale lobate-scarp thrust faults reveal that the planet’s tectonic history has been dominated by global contraction, primarily due to cooling of its interior. Constraining the timing and duration of this contraction provides key insight into Mercury’s thermal and geologic evolution. We combine two techniques to enhance the statistical validity of size-frequency distribution crater analyses and constrain timing of the 1) earliest and 2) most recent detectable activity on several of Mercury’s largest lobate-scarp thrust faults. We use the sizes of craters directly transected by or superposed on the edge of the scarp face to define a count area around the scarp, a method we call the Modified Buffered Crater Counting Technique (MBCCT). We developed the MBCCT to avoid the issue of a near-zero scarp width since feature widths are included in area calculations of the commonly used Buffered Crater Counting Technique (BCCT). Since only craters directly intersecting the scarp face edge conclusively show evidence of crosscutting relations, we increase the number of craters in our analysis (and reduce uncertainties) by using the morphologic degradation state (i.e. relative age) of these intersecting craters to classify other similarly degraded craters within the count area (i.e., those with the same relative age) as superposing or transected. The resulting crater counts are divided into two categories: transected craters constrain the earliest possible activity and superposed craters constrain the most recent detectable activity. Absolute ages are computed for each population using the Marchi et al. [2009] model production function. A test of the Blossom lobate scarp indicates the MBCCT gives statistically equivalent results to the BCCT. We find that all scarps in this study crosscut surfaces Tolstojan or older in age (>~3.7 Ga). The most recent detectable activity along lobate-scarp thrust faults ranges from Calorian to Kuiperian (~3.7 Ga to present). Our results complement previous relative-age studies with absolute ages and indicate global contraction continued over the last ~3-4 Gyr. At least some thrust fault activity occurred on Mercury in relatively recent times (<280 Ma).
DOE Office of Scientific and Technical Information (OSTI.GOV)
Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril
High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less
Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; ...
2017-10-09
High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ~6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the artmore » and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr 3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr 3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2” (length) × 2” (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ~3 Mcps. An experimental methodology was developed that uses the average current from the PMT’s anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr 3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ~3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.« less
NASA Astrophysics Data System (ADS)
Favalli, Andrea; Iliev, Metodi; Ianakiev, Kiril; Hunt, Alan W.; Ludewigt, Bernhard
2018-01-01
High-energy delayed γ-ray spectroscopy is a potential technique for directly assaying spent fuel assemblies and achieving the safeguards goal of quantifying nuclear material inventories for spent fuel handling, interim storage, reprocessing facilities, repository sites, and final disposal. Requirements for the γ-ray detection system, up to ∼6 MeV, can be summarized as follows: high efficiency at high γ-ray energies, high energy resolution, good linearity between γ-ray energy and output signal amplitude, ability to operate at very high count rates, and ease of use in industrial environments such as nuclear facilities. High Purity Germanium Detectors (HPGe) are the state of the art and provide excellent energy resolution but are limited in their count rate capability. Lanthanum Bromide (LaBr3) scintillation detectors offer significantly higher count rate capabilities at lower energy resolution. Thus, LaBr3 detectors may be an effective alternative for nuclear spent-fuel applications, where count-rate capability is a requirement. This paper documents the measured performance of a 2" (length) × 2" (diameter) of LaBr3 scintillation detector system, coupled to a negatively biased PMT and a tapered active high voltage divider, with count-rates up to ∼3 Mcps. An experimental methodology was developed that uses the average current from the PMT's anode and a dual source method to characterize the detector system at specific very high count rate values. Delayed γ-ray spectra were acquired with the LaBr3 detector system at the Idaho Accelerator Center, Idaho State University, where samples of ∼3g of 235U were irradiated with moderated neutrons from a photo-neutron source. Results of the spectroscopy characterization and analysis of the delayed γ-ray spectra acquired indicate the possible use of LaBr3 scintillation detectors when high count rate capability may outweigh the lower energy resolution.
Costs of detection bias in index-based population monitoring
Moore, C.T.; Kendall, W.L.
2004-01-01
Managers of wildlife populations commonly rely on indirect, count-based measures of the population in making decisions regarding conservation, harvest, or control. The main appeal in the use of such counts is their low material expense compared to methods that directly measure the population. However, their correct use rests on the rarely-tested but often-assumed premise that they proportionately reflect population size, i.e., that they constitute a population index. This study investigates forest management for the endangered Red-cockaded Woodpecker (Picoides borealis) and the Wood Thrush (Hylocichla mustelina) at the Piedmont National Wildlife Refuge in central Georgia, U.S.A. Optimal decision policies for a joint species objective were derived for two alternative models of Wood Thrush population dynamics. Policies were simulated under scenarios of unbiasedness, consistent negative bias, and habitat-dependent negative bias in observed Wood Thrush densities. Differences in simulation outcomes between biased and unbiased detection scenarios indicated the expected loss in resource objectives (here, forest habitat and birds) through decision-making based on biased population counts. Given the models and objective function used in our analysis, expected losses were as great as 11%, a degree of loss perhaps not trivial for applications such as endangered species management. Our analysis demonstrates that costs of uncertainty about the relationship between the population and its observation can be measured in units of the resource, costs which may offset apparent savings achieved by collecting uncorrected population counts.
The HIV care cascade: a systematic review of data sources, methodology and comparability.
Medland, Nicholas A; McMahon, James H; Chow, Eric P F; Elliott, Julian H; Hoy, Jennifer F; Fairley, Christopher K
2015-01-01
The cascade of HIV diagnosis, care and treatment (HIV care cascade) is increasingly used to direct and evaluate interventions to increase population antiretroviral therapy (ART) coverage, a key component of treatment as prevention. The ability to compare cascades over time, sub-population, jurisdiction or country is important. However, differences in data sources and methodology used to construct the HIV care cascade might limit its comparability and ultimately its utility. Our aim was to review systematically the different methods used to estimate and report the HIV care cascade and their comparability. A search of published and unpublished literature through March 2015 was conducted. Cascades that reported the continuum of care from diagnosis to virological suppression in a demographically definable population were included. Data sources and methods of measurement or estimation were extracted. We defined the most comparable cascade elements as those that directly measured diagnosis or care from a population-based data set. Thirteen reports were included after screening 1631 records. The undiagnosed HIV-infected population was reported in seven cascades, each of which used different data sets and methods and could not be considered to be comparable. All 13 used mandatory HIV diagnosis notification systems to measure the diagnosed population. Population-based data sets, derived from clinical data or mandatory reporting of CD4 cell counts and viral load tests from all individuals, were used in 6 of 12 cascades reporting linkage, 6 of 13 reporting retention, 3 of 11 reporting ART and 6 of 13 cascades reporting virological suppression. Cascades with access to population-based data sets were able to directly measure cascade elements and are therefore comparable over time, place and sub-population. Other data sources and methods are less comparable. To ensure comparability, countries wishing to accurately measure the cascade should utilize complete population-based data sets from clinical data from elements of a centralized healthcare setting, where available, or mandatory CD4 cell count and viral load test result reporting. Additionally, virological suppression should be presented both as percentage of diagnosed and percentage of estimated total HIV-infected population, until methods to calculate the latter have been standardized.
Lodwick, Rebecca K; Nakagawa, Fumiyo; van Sighem, Ard; Sabin, Caroline A; Phillips, Andrew N
2015-01-01
It is important to have methods available to estimate the number of people who have undiagnosed HIV and are in need of antiretroviral therapy (ART). The method uses the concept that a predictable level of occurrence of AIDS or other HIV-related clinical symptoms which lead to presentation for care, and hence diagnosis of HIV, arises in undiagnosed people with a given CD4 count. The method requires surveillance data on numbers of new HIV diagnoses with HIV-related symptoms, and the CD4 count at diagnosis. The CD4 count-specific rate at which HIV-related symptoms develop are estimated from cohort data. 95% confidence intervals can be constructed using a simple simulation method. For example, if there were 13 HIV diagnoses with HIV-related symptoms made in one year with CD4 count at diagnosis between 150-199 cells/mm3, then since the CD4 count-specific rate of HIV-related symptoms is estimated as 0.216 per person-year, the estimated number of person years lived in people with undiagnosed HIV with CD4 count 150-199 cells/mm3 is 13/0.216 = 60 (95% confidence interval: 29-100), which is considered an estimate of the number of people living with undiagnosed HIV in this CD4 count stratum. The method is straightforward to implement within a short period once a surveillance system of all new HIV diagnoses, collecting data on HIV-related symptoms at diagnosis, is in place and is most suitable for estimating the number of undiagnosed people with CD4 count <200 cells/mm3 due to the low rate of developing HIV-related symptoms at higher CD4 counts. A potential source of bias is under-diagnosis and under-reporting of diagnoses with HIV-related symptoms. Although this method has limitations as with all approaches, it is important for prompting increased efforts to identify undiagnosed people, particularly those with low CD4 count, and for informing levels of unmet need for ART.
Efficacy of guided spiral drawing in the classification of Parkinson's Disease.
Zham, Poonam; Arjunan, Sridhar; Raghav, Sanjay; Kumar, Dinesh Kant
2017-10-11
Change of handwriting can be an early marker for severity of Parkinson's disease but suffers from poor sensitivity and specificity due to inter-subject variations. This study has investigated the group-difference in the dynamic features during sketching of spiral between PD and control subjects with the aim of developing an accurate method for diagnosing PD patients. Dynamic handwriting features were computed for 206 specimens collected from 62 Subjects (31 Parkinson's and 31 Controls). These were analyzed based on the severity of the disease to determine group-difference. Spearman rank correlation coefficient was computed to evaluate the strength of association for the different features. Maximum area under ROC curve (AUC) using the dynamic features during different writing and spiral sketching tasks were in the range of 67 to 79 %. However, when angular features ( and ) and count of direction inversion during sketching of the spiral were used, AUC improved to 93.3%. Spearman correlation coefficient was highest for and . The angular features and count of direction inversion which can be obtained in real-time while sketching the Archimedean guided spiral on a digital tablet can be used for differentiating between Parkinson's and healthy cohort.
Murray, Andrew D; Turner, Kieran; Archibald, Daryll; Schiphorst, Chloe; Griffin, Steffan Arthur; Scott, Hilary; Hawkes, Roger; Kelly, Paul; Grant, Liz; Mutrie, Nanette
2017-01-01
Background Spectators at several hundred golf tournaments on six continents worldwide may gain health-enhancing physical activity (HEPA) during their time at the event. This study aims to investigate spectators’ reasons for attending and assess spectator physical activity (PA) (measured by step count). Methods Spectators at the Paul Lawrie Matchplay event in Scotland (August 2016) were invited to take part in this study. They were asked to complete a brief questionnaire with items to assess (1) demographics, (2) reasons for attendance and (3) baseline PA. In addition, participants were requested to wear a pedometer from time of entry to the venue until exit. Results A total of 339 spectators were recruited to the study and out of which 329 (97.2%) returned step-count data. Spectators took a mean of 11 589 steps (SD 4531). ‘Fresh air’ (rated median 9 out of 10) then ‘watching star players’, ‘exercise/physical activity’, ‘time with friends and family’ and ‘atmosphere’ (all median 8 out of 10) were rated the most important reasons for attending. Conclusion This study is the first to assess spectator physical activity while watching golf (measured by step count). Obtaining exercise/PA is rated as an important reason for attending a tournament by many golf spectators. Spectating at a golf tournament can provide HEPA. 82.9% of spectators achieved the recommended daily step count while spectating. Further research directly assessing whether spectating may constitute a ‘teachable moment’, for increasing physical activity beyond the tournament itself, is merited. PMID:28761718
Schmidt, Benedikt R
2003-08-01
The evidence for amphibian population declines is based on count data that were not adjusted for detection probabilities. Such data are not reliable even when collected using standard methods. The formula C = Np (where C is a count, N the true parameter value, and p is a detection probability) relates count data to demography, population size, or distributions. With unadjusted count data, one assumes a linear relationship between C and N and that p is constant. These assumptions are unlikely to be met in studies of amphibian populations. Amphibian population data should be based on methods that account for detection probabilities.
Uncertainty of quantitative microbiological methods of pharmaceutical analysis.
Gunar, O V; Sakhno, N G
2015-12-30
The total uncertainty of quantitative microbiological methods, used in pharmaceutical analysis, consists of several components. The analysis of the most important sources of the quantitative microbiological methods variability demonstrated no effect of culture media and plate-count techniques in the estimation of microbial count while the highly significant effect of other factors (type of microorganism, pharmaceutical product and individual reading and interpreting errors) was established. The most appropriate method of statistical analysis of such data was ANOVA which enabled not only the effect of individual factors to be estimated but also their interactions. Considering all the elements of uncertainty and combining them mathematically the combined relative uncertainty of the test results was estimated both for method of quantitative examination of non-sterile pharmaceuticals and microbial count technique without any product. These data did not exceed 35%, appropriated for a traditional plate count methods. Copyright © 2015 Elsevier B.V. All rights reserved.
Nagy, P; Faye, B; Marko, O; Thomas, S; Wernery, U; Juhasz, J
2013-09-01
The objectives of the present study were to monitor the microbiological quality and somatic cell count (SCC) of bulk tank milk at the world's first large-scale camel dairy farm for a 2-yr period, to compare the results of 2 methods for the enumeration of SCC, to evaluate correlation among milk quality indicators, and to determine the effect of specific factors (year, season, stage of lactation, and level of production) on milk quality indicators. The study was conducted from January 2008 to January 2010. Total viable count (TVC), coliform count (CC), California Mastitis Test (CMT) score, and SCC were determined from daily bulk milk samples. Somatic cell count was measured by using a direct microscopic method and with an automatic cell counter. In addition, production parameters [total daily milk production (TDM, kg), number of milking camels (NMC), average milk per camel (AMC, kg)] and stage of lactation (average postpartum days, PPD) were recorded for each test day. A strong correlation (r=0.33) was found between the 2 methods for SCC enumeration; however, values derived using the microscopic method were higher. The geometric means of SCC and TVC were 394×10(3) cells/mL and 5,157 cfu/mL during the observation period, respectively. Somatic cell count was >500×10(3) cells/mL on 14.6% (106/725) and TVC was >10×10(3) cfu/mL on 4.0% (30/742) of the test days. Both milk quality indicators had a distinct seasonal pattern. For log SCC, the mean was lowest in summer and highest in autumn. The seasonal pattern of log TVC was slightly different, with the lowest values being recorded during the spring. The monthly mean TVC pattern showed a clear difference between years. Coliform count was <10 cfu/mL in most of the samples (709/742, 95.6%). A positive correlation was found between log SCC and log TVC (r=0.32), between log SCC and CMT score (r=0.26), and between log TVC and CC in yr 1 (r=0.30). All production parameters and stage of lactation showed strong seasonal variation. Log SCC was negatively correlated with TDM (r=-0.35), AMC (r=-0.37), and NMC (r=-0.15) and positively correlated with PPD (r=0.40). Log TVC had a negative correlation with AMC (r=-0.40) but a positive correlation with NMC (r=0.32), TDM (r=0.16), and PPD (r=0.45). The linear mixed model with stepwise variable selection showed that the main sources of log SCC variation were PPD, TDM, PPD × season, and season. For log TVC, the same factors and year contributed to the variation. Copyright © 2013 American Dairy Science Association. Published by Elsevier Inc. All rights reserved.
Accelerating the two-point and three-point galaxy correlation functions using Fourier transforms
NASA Astrophysics Data System (ADS)
Slepian, Zachary; Eisenstein, Daniel J.
2016-01-01
Though Fourier transforms (FTs) are a common technique for finding correlation functions, they are not typically used in computations of the anisotropy of the two-point correlation function (2PCF) about the line of sight in wide-angle surveys because the line-of-sight direction is not constant on the Cartesian grid. Here we show how FTs can be used to compute the multipole moments of the anisotropic 2PCF. We also show how FTs can be used to accelerate the 3PCF algorithm of Slepian & Eisenstein. In both cases, these FT methods allow one to avoid the computational cost of pair counting, which scales as the square of the number density of objects in the survey. With the upcoming large data sets of Dark Energy Spectroscopic Instrument, Euclid, and Large Synoptic Survey Telescope, FT techniques will therefore offer an important complement to simple pair or triplet counts.
AIR SCORE ASSESSMENT FOR ACUTE APPENDICITIS
VON-MÜHLEN, Bruno; FRANZON, Orli; BEDUSCHI, Murilo Gamba; KRUEL, Nicolau; LUPSELO, Daniel
2015-01-01
Background: Acute appendicitis is the most common cause of acute abdomen. Approximately 7% of the population will be affected by this condition during full life. The development of AIR score may contribute to diagnosis associating easy clinical criteria and two simple laboratory tests. Aim: To evaluate the score AIR (Appendicitis Inflammatory Response score) as a tool for the diagnosis and prediction of severity of acute appendicitis. Method: Were evaluated all patients undergoing surgical appendectomy. From 273 patients, 126 were excluded due to exclusion criteria. All patients were submitted o AIR score. Results: The value of the C-reactive protein and the percentage of leukocytes segmented blood count showed a direct relationship with the phase of acute appendicitis. Conclusion: As for the laboratory criteria, serum C-reactive protein and assessment of the percentage of the polymorphonuclear leukocytes count were important to diagnosis and disease stratification. PMID:26537139
A new device for dynamic sampling of radon in air
NASA Astrophysics Data System (ADS)
Lozano, J. C.; Escobar, V. Gómez; Tomé, F. Vera
2000-08-01
A new system is proposed for the active sampling of radon in air, based on the well-known property of activated charcoal to retain radon. Two identical carbon-activated cartridges arranged in series remove the radon from the air being sampled. The air passes first through a desiccant cell and then the carbon cartridges for short sampling times using a low-flow pump. The alpha activity for each cartridge is determined by a liquid scintillation counting system. The cartridge is placed in a holder into a vial that also contains the appropriate amount of scintillation cocktail, in a way that avoids direct contact between cocktail and charcoal. Once dynamic equilibrium between the phases has been reached, the vials can be counted. Optimum sampling conditions concerning flow rates and sampling times are determined. Using those conditions, the method was applied to environmental samples, straightforwardly providing good results for very different levels of activity.
Kosuda, S; Arai, S; Hohshito, Y; Tokumitsu, H; Kusano, S; Ishihara, S; Shima, K
1998-07-01
A combination study of cerebrospinal fluid scintigraphy and nasal pledget counts was performed using 37 MBq of 111In-DTPA in 12 patients with suspected rhinorrhea. A pledget was inserted and dwelled in each nasal cavity for 6 hours, with the patient prone during at least 30 minutes. A total of 18 studies was implemented and nasal pledget counting method successfully diagnosed all of CSF rhinorrhea. Diagnosis was possible when pledget counts were greater than 1 kcpm. In patients with persistent, intermittent and occult/no nasal discharge, rhinorrhea was found in 100% (5/5), 60% (3/5), 25% (2/8), respectively. Two cases only exhibited positive scintigraphy. MRI or CT cisternography should be first performed in patients with persistent discharge, but in patients with intermittent/occult discharge pledget counting method might take priority of other diagnostic modalities. In conclusion, nasal pledget counting method is a simple and useful tool for detecting rhinorrhea.
Wilson, Floyd D; Johnson, Deirdre I; Magee, Danny L; Hoerr, Frederic J
2018-05-01
Testicular histomorphometric methods were developed for the investigation of fertility and hatchability problems in commercial broiler-breeder roosters. Sertoli cell (SC) evaluations were emphasized in view of their role in influencing embryonic testicular organogenesis and spermatogenesis in adults. H&E stained sections prepared from formalized tissues were examined. SC evaluations were mostly made from computer generated images using image analysis software, but were also compared to direct counting with ocular grid reticle. Other measurements were germinal epithelial and total seminiferous tubule widths, quantification of individual spermatozoa and sperm clusters, and determinations of stromal area. Age-associated changes in SC occurred between 15 to 54 wk of age. A significant reduction in SC concentration occurred at 29 wk of age (P < 0.001) that corresponded with the histologic initiation of spermatogenesis. Expanded morphometric evaluations were performed on 59-week-old roosters comparing a flock having good body condition and footpad scores with normal testicular and body weights (optimal profile or OP group) to a second flock demonstrating relatively poor expression of these parameters and decreased fertility (sub-optimal profile or SOP group). Significant reductions (P < 0.05) in SC concentration, spermatozoa, and tubular widths, but an increased percentage of stroma area occurred in SOP compared to OP flocks. SC results also correlated well with testes weight. A unique finding was a significant relationship between decreasing SC concentration and increasing severity scores for footpad lesions. Differences in all histomorphometric parameters occurred between flocks demonstrating good hatchability compared to flocks exhibiting either low or decreasing hatchability. Significant reductions in SC and other morphometric parameters were observed for the poor relative to good hatchability group. A strong positive association was observed for SC results using computer generated images and direct reticle ocular counting (R = 0.80). Replicate counts on control sections demonstrated generally good reproducibility of methods between experiments. The findings are supportive of the value of testicular histomorphometrics for evaluations of hatchability issues in commercial roosters.
A statistical approach for inferring the 3D structure of the genome.
Varoquaux, Nelle; Ay, Ferhat; Noble, William Stafford; Vert, Jean-Philippe
2014-06-15
Recent technological advances allow the measurement, in a single Hi-C experiment, of the frequencies of physical contacts among pairs of genomic loci at a genome-wide scale. The next challenge is to infer, from the resulting DNA-DNA contact maps, accurate 3D models of how chromosomes fold and fit into the nucleus. Many existing inference methods rely on multidimensional scaling (MDS), in which the pairwise distances of the inferred model are optimized to resemble pairwise distances derived directly from the contact counts. These approaches, however, often optimize a heuristic objective function and require strong assumptions about the biophysics of DNA to transform interaction frequencies to spatial distance, and thereby may lead to incorrect structure reconstruction. We propose a novel approach to infer a consensus 3D structure of a genome from Hi-C data. The method incorporates a statistical model of the contact counts, assuming that the counts between two loci follow a Poisson distribution whose intensity decreases with the physical distances between the loci. The method can automatically adjust the transfer function relating the spatial distance to the Poisson intensity and infer a genome structure that best explains the observed data. We compare two variants of our Poisson method, with or without optimization of the transfer function, to four different MDS-based algorithms-two metric MDS methods using different stress functions, a non-metric version of MDS and ChromSDE, a recently described, advanced MDS method-on a wide range of simulated datasets. We demonstrate that the Poisson models reconstruct better structures than all MDS-based methods, particularly at low coverage and high resolution, and we highlight the importance of optimizing the transfer function. On publicly available Hi-C data from mouse embryonic stem cells, we show that the Poisson methods lead to more reproducible structures than MDS-based methods when we use data generated using different restriction enzymes, and when we reconstruct structures at different resolutions. A Python implementation of the proposed method is available at http://cbio.ensmp.fr/pastis. © The Author 2014. Published by Oxford University Press.
Sebastian, Roby; Ratliff, Todd; Winch, Peter D; Tumin, Dmitry; Gomez, Daniel; Tobias, Joseph; Galantowicz, Mark; Naguib, Aymen N
2017-01-01
The majority of allogeneic transfusions occur in the perioperative setting, especially during cardiac surgery. In addition to the economic implications, there is emerging evidence that blood transfusion may increase both morbidity and mortality. Acute normovolemic hemodilution (ANH) may limit the need for blood products. The primary objective of this study was to determine if the method of blood collection (syringe or bag) during the ANH process impacted the platelet count and function. The secondary objectives included the need for perioperative blood transfusions during the procedure and in the intensive care unit. In addition, we assessed these outcomes' associations with ANH parameters including the method of collection, time of storage, and volume removed. Data were collected prospectively from 50 patients undergoing cardiac surgery on cardiopulmonary bypass over a 6-month period. Platelet count and function were measured for the ANH blood immediately after collection and again prior to transfusing to the patient at the end of cardiopulmonary bypass. Other data collected included ANH volume, length of storage, and the quantity of all blood products given throughout the perioperative period. No change in platelet count or function was noted regardless of the length of time or collection method for the ANH blood. Twenty-three patients received blood or blood products in the operating room or the intensive care unit, while 27 patients received no blood transfusion during their entire hospitalization. Higher ANH volume (ml·kg -1 ) and longer storage time were associated with a greater need for intraoperative transfusions. Acute normovolemic hemodilution protects the platelets from the untoward effects of cardiopulmonary bypass and offers an important autologous blood product that improves hemostasis at the conclusion of surgery. Platelet count and function are preserved regardless of the method of collection or the length of storage. The volume of ANH removed appears to be an important determinant of blood product use and further understanding of the impact of this variable is a future direction of upcoming prospective research. © 2016 John Wiley & Sons Ltd.
Reviving common standards in point-count surveys for broad inference across studies
Matsuoka, Steven M.; Mahon, C. Lisa; Handel, Colleen M.; Solymos, Peter; Bayne, Erin M.; Fontaine, Patricia C.; Ralph, C.J.
2014-01-01
We revisit the common standards recommended by Ralph et al. (1993, 1995a) for conducting point-count surveys to assess the relative abundance of landbirds breeding in North America. The standards originated from discussions among ornithologists in 1991 and were developed so that point-count survey data could be broadly compared and jointly analyzed by national data centers with the goals of monitoring populations and managing habitat. Twenty years later, we revisit these standards because (1) they have not been universally followed and (2) new methods allow estimation of absolute abundance from point counts, but these methods generally require data beyond the original standards to account for imperfect detection. Lack of standardization and the complications it introduces for analysis become apparent from aggregated data. For example, only 3% of 196,000 point counts conducted during the period 1992-2011 across Alaska and Canada followed the standards recommended for the count period and count radius. Ten-minute, unlimited-count-radius surveys increased the number of birds detected by >300% over 3-minute, 50-m-radius surveys. This effect size, which could be eliminated by standardized sampling, was ≥10 times the published effect sizes of observers, time of day, and date of the surveys. We suggest that the recommendations by Ralph et al. (1995a) continue to form the common standards when conducting point counts. This protocol is inexpensive and easy to follow but still allows the surveys to be adjusted for detection probabilities. Investigators might optionally collect additional information so that they can analyze their data with more flexible forms of removal and time-of-detection models, distance sampling, multiple-observer methods, repeated counts, or combinations of these methods. Maintaining the common standards as a base protocol, even as these study-specific modifications are added, will maximize the value of point-count data, allowing compilation and analysis by regional and national data centers.
NASA Astrophysics Data System (ADS)
Weber, M. E.; Reichelt, L.; Kuhn, G.; Thurow, J. W.; Ricken, W.
2009-12-01
We present software-based tools for rapid and quantitative detection of sediment lamination. The BMPix tool extracts color and gray-scale curves from images at ultrahigh (pixel) resolution. The PEAK tool uses the gray-scale curve and performs, for the first time, fully automated counting of laminae based on three methods. The maximum count algorithm counts every bright peak of a couplet of two laminae (annual resolution) in a Gaussian smoothed gray-scale curve. The zero-crossing algorithm counts every positive and negative halfway-passage of the gray-scale curve through a wide moving average. Hence, the record is separated into bright and dark intervals (seasonal resolution). The same is true for the frequency truncation method, which uses Fourier transformation to decompose the gray-scale curve into its frequency components, before positive and negative passages are count. We applied the new methods successfully to tree rings and to well-dated and already manually counted marine varves from Saanich Inlet before we adopted the tools to rather complex marine laminae from the Antarctic continental margin. In combination with AMS14C dating, we found convincing evidence that the laminations from three Weddell Sea sites represent true varves that were deposited on sediment ridges over several millennia during the last glacial maximum (LGM). There are apparently two seasonal layers of terrigenous composition, a coarser-grained bright layer, and a finer-grained dark layer. The new tools offer several advantages over previous tools. The counting procedures are based on a moving average generated from gray-scale curves instead of manual counting. Hence, results are highly objective and rely on reproducible mathematical criteria. Since PEAK associates counts with a specific depth, the thickness of each year or each season is also measured which is an important prerequisite for later spectral analysis. Since all information required to conduct the analysis is displayed graphically, interactive optimization of the counting algorithms can be achieved quickly and conveniently.
Automated vehicle counting using image processing and machine learning
NASA Astrophysics Data System (ADS)
Meany, Sean; Eskew, Edward; Martinez-Castro, Rosana; Jang, Shinae
2017-04-01
Vehicle counting is used by the government to improve roadways and the flow of traffic, and by private businesses for purposes such as determining the value of locating a new store in an area. A vehicle count can be performed manually or automatically. Manual counting requires an individual to be on-site and tally the traffic electronically or by hand. However, this can lead to miscounts due to factors such as human error A common form of automatic counting involves pneumatic tubes, but pneumatic tubes disrupt traffic during installation and removal, and can be damaged by passing vehicles. Vehicle counting can also be performed via the use of a camera at the count site recording video of the traffic, with counting being performed manually post-recording or using automatic algorithms. This paper presents a low-cost procedure to perform automatic vehicle counting using remote video cameras with an automatic counting algorithm. The procedure would utilize a Raspberry Pi micro-computer to detect when a car is in a lane, and generate an accurate count of vehicle movements. The method utilized in this paper would use background subtraction to process the images and a machine learning algorithm to provide the count. This method avoids fatigue issues that are encountered in manual video counting and prevents the disruption of roadways that occurs when installing pneumatic tubes
Salehi, Sohrab; Steif, Adi; Roth, Andrew; Aparicio, Samuel; Bouchard-Côté, Alexandre; Shah, Sohrab P
2017-03-01
Next-generation sequencing (NGS) of bulk tumour tissue can identify constituent cell populations in cancers and measure their abundance. This requires computational deconvolution of allelic counts from somatic mutations, which may be incapable of fully resolving the underlying population structure. Single cell sequencing (SCS) is a more direct method, although its replacement of NGS is impeded by technical noise and sampling limitations. We propose ddClone, which analytically integrates NGS and SCS data, leveraging their complementary attributes through joint statistical inference. We show on real and simulated datasets that ddClone produces more accurate results than can be achieved by either method alone.
2012-01-01
Background The quality and safety of advanced therapy products must be maintained throughout their production and quality control cycle to ensure their final use in patients. We validated the cell count method according to the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use and European Pharmacopoeia, considering the tests’ accuracy, precision, repeatability, linearity and range. Methods As the cell count is a potency test, we checked accuracy, precision, and linearity, according to ICH Q2. Briefly our experimental approach was first to evaluate the accuracy of Fast Read 102® compared to the Bürker chamber. Once the accuracy of the alternative method was demonstrated, we checked the precision and linearity test only using Fast Read 102®. The data were statistically analyzed by average, standard deviation and coefficient of variation percentages inter and intra operator. Results All the tests performed met the established acceptance criteria of a coefficient of variation of less than ten percent. For the cell count, the precision reached by each operator had a coefficient of variation of less than ten percent (total cells) and under five percent (viable cells). The best range of dilution, to obtain a slope line value very similar to 1, was between 1:8 and 1:128. Conclusions Our data demonstrated that the Fast Read 102® count method is accurate, precise and ensures the linearity of the results obtained in a range of cell dilution. Under our standard method procedures, this assay may thus be considered a good quality control method for the cell count as a batch release quality control test. Moreover, the Fast Read 102® chamber is a plastic, disposable device that allows a number of samples to be counted in the same chamber. Last but not least, it overcomes the problem of chamber washing after use and so allows a cell count in a clean environment such as that in a Cell Factory. In a good manufacturing practice setting the disposable cell counting devices will allow a single use of the count chamber they can then be thrown away, thus avoiding the waste disposal of vital dye (e.g. Trypan Blue) or lysing solution (e.g. Tuerk solution). PMID:22650233
Fu, Xin; Huang, Kelong; Liu, Suqin
2010-02-01
In this paper, a rapid, simple, and sensitive method was described for detection of the total bacterial count using SiO(2)-coated CdSe/ZnS quantum dots (QDs) as a fluorescence marker that covalently coupled with bacteria using glutaraldehyde as the crosslinker. Highly luminescent CdSe/ZnS were prepared by applying cadmium oxide and zinc stearate as precursors instead of pyrophoric organometallic precursors. A reverse-microemulsion technique was used to synthesize CdSe/ZnS/SiO(2) composite nanoparticles with a SiO(2) surface coating. Our results showed that CdSe/ZnS/SiO(2) composite nanoparticles prepared with this method possessed highly luminescent, biologically functional, and monodispersive characteristics, and could successfully be covalently conjugated with the bacteria. As a demonstration, it was found that the method had higher sensitivity and could count bacteria in 3 x 10(2) CFU/mL, lower than the conventional plate counting and organic dye-based method. A linear relationship of the fluorescence peak intensity (Y) and the total bacterial count (X) was established in the range of 3 x 10(2)-10(7) CFU/mL using the equation Y = 374.82X-938.27 (R = 0.99574). The results of the determination for the total count of bacteria in seven real samples were identical with the conventional plate count method, and the standard deviation was satisfactory.
Genetic parameters for fecal egg count and body weight in Katahdin lambs
USDA-ARS?s Scientific Manuscript database
The objective of this study was to estimate genetic parameters for fecal egg count at weaning (WFEC) and post weaning (PWFEC), and weights at birth (BW), weaning (WW) and post weaning (PWW) in Katahdin lambs by investigating direct additive, maternal additive, maternal permanent environmental and ma...
77 FR 73557 - Airworthiness Directives; Turbomeca S.A. Turboshaft Engines
Federal Register 2010, 2011, 2012, 2013, 2014
2012-12-11
... turboshaft engines. This proposed AD was prompted by a finding that the engine's tachometer unit cycle... tachometer's unit cycle counting feature. This proposed AD would also require ground-run functional checks... accuracy of the engine's tachometer cycle counting feature. We are proposing this AD to prevent uncontained...
Benefits of automated surface decontamination of a radioiodine ward.
Westcott, Eliza; Broadhurst, Alicia; Crossley, Steven; Lee, Lloyd; Phan, Xuyen; Scharli, Rainer; Xu, Yan
2012-02-01
A floor-washing robot has been acquired to assist physicists with decontamination of radioiodine therapy ward rooms after discharge of the patient at Sir Charles Gairdner Hospital. The effectiveness of the robot in decontaminating the ward has been evaluated. A controlled experiment was performed by deliberately contaminating a polyvinyl chloride flooring offcut with 131I followed by automated decontamination with the robot. The extent of fixed and removable contamination was assessed before and after decontamination by two methods: (1) direct Geiger-Mueller counting and (2) beta-counting wipe tests. Surface contamination was also assessed in situ on the ward by Geiger-Mueller counting and wipe testing. Contamination maps confirmed that contamination was removed rather than spread around by the robot. Wipe testing revealed that the robot was successful in clearing approximately 60-80% of removable contamination. The robotic floor-washing device was considered suitable to provide effective automated decontamination of the radioiodine ward. In addition, the robot affords other benefits: the time spent by the physicists decontaminating the room is greatly reduced offering financial and occupational safety and health benefits. The robot has also found utility in other decontamination applications in the healthcare environment.
Non-calcified coronary plaque volume inversely related to CD4 count in HIV infection
Duarte, Horacio; Matta, Jatin R.; Muldoon, Nancy; Masur, Henry; Hadigan, Colleen; Gharib, Ahmed M.
2013-01-01
Background Non-calcified coronary artery plaque (NCAP) may be an important predictor of cardiovascular events, however, few studies have directly measured NCAP in HIV-infected individuals. Methods We completed a prospective cross-sectional evaluation of NCAP and coronary calcium scores using CT angiography in HIV-infected subjects (n=26) without known coronary artery disease (CAD), but who had one or more CAD risk factor and compared them to controls matched on age, race, sex, body mass index and Framingham risk score (n=26). Results There was no difference in coronary calcium scores (114 ± 218 vs. 124 ± 298 p=0.89) or NCAP volume (65 ± 86 mm3 vs. 63 ± 82 mm3, p=0.38) between HIV-infected subjects and controls, respectively. Among HIV-infected subjects, lower CD4 count was associated with increased NCAP volume (r=-0.52, p=0.006). CD4 count remained a significant predictor of NCAP in a multivariate analysis that adjusted for age and duration of antiretroviral therapy. Conclusion Plaque burden is similar between HIV-infected and uninfected individuals when matched on traditional CAD risk factors, however immune function may mediate the development of atherosclerosis in HIV infection. PMID:22293714
Liu, Lu; Ammar, David A.; Ross, Lindsey A.; Mandava, Naresh; Kahook, Malik Y.
2011-01-01
Purpose. To quantify levels of subvisible particles and protein aggregates in repackaged bevacizumab obtained from compounding pharmacies, as well as in samples of bevacizumab and ranibizumab tested in controlled laboratory experiments. Methods. Repackaged bevacizumab was purchased from four external compounding pharmacies. For controlled laboratory studies, bevacizumab and placebo were drawn into plastic syringes and incubated at −20°C, 4°C, and room temperature (with and without exposure to light) for 12 weeks. In addition, mechanical shock occurring during shipping was mimicked with syringes containing bevacizumab. Particle counts and size distributions were quantified by particle characterization technology. Levels of monomer and soluble aggregates of bevacizumab were determined with size-exclusion high-performance liquid chromatography (SE-HPLC). Results. Repackaged bevacizumab from the compounding pharmacies had a wide range of particle counts (89,006 ± 56,406 to 602,062 ± 18,349/mL). Bevacizumab sampled directly from the original glass vial had particle counts of 63,839 ± 349/mL. There was up to a 10% monomer loss in the repackaged bevacizumab. Laboratory samples of repackaged bevacizumab and placebo had initial particle counts, respectively, of 283,675 ± 60,494/mL and 492,314 ± 389,361/mL. Freeze-thawing of both bevacizumab and placebo samples led to >1.2 million particles/mL. In all repackaged samples, most of the particles were due to silicone oil. SE-HPLC showed no significant differences for repackaged samples incubated in the laboratory under various conditions, compared with bevacizumab directly from vial. However, repeated freeze-thawing caused a more than 10% monomer loss. Conclusions. Bevacizumab repackaged in plastic syringes could contain protein aggregates and is contaminated by silicone oil microdroplets. Freeze-thawing or other mishandling can further increase levels of particle contaminants. PMID:21051703
NASA Astrophysics Data System (ADS)
Raupov, Dmitry S.; Myakinin, Oleg O.; Bratchenko, Ivan A.; Kornilin, Dmitry V.; Zakharov, Valery P.; Khramov, Alexander G.
2016-04-01
Optical coherence tomography (OCT) is usually employed for the measurement of tumor topology, which reflects structural changes of a tissue. We investigated the possibility of OCT in detecting changes using a computer texture analysis method based on Haralick texture features, fractal dimension and the complex directional field method from different tissues. These features were used to identify special spatial characteristics, which differ healthy tissue from various skin cancers in cross-section OCT images (B-scans). Speckle reduction is an important pre-processing stage for OCT image processing. In this paper, an interval type-II fuzzy anisotropic diffusion algorithm for speckle noise reduction in OCT images was used. The Haralick texture feature set includes contrast, correlation, energy, and homogeneity evaluated in different directions. A box-counting method is applied to compute fractal dimension of investigated tissues. Additionally, we used the complex directional field calculated by the local gradient methodology to increase of the assessment quality of the diagnosis method. The complex directional field (as well as the "classical" directional field) can help describe an image as set of directions. Considering to a fact that malignant tissue grows anisotropically, some principal grooves may be observed on dermoscopic images, which mean possible existence of principal directions on OCT images. Our results suggest that described texture features may provide useful information to differentiate pathological from healthy patients. The problem of recognition melanoma from nevi is decided in this work due to the big quantity of experimental data (143 OCT-images include tumors as Basal Cell Carcinoma (BCC), Malignant Melanoma (MM) and Nevi). We have sensitivity about 90% and specificity about 85%. Further research is warranted to determine how this approach may be used to select the regions of interest automatically.
Bouwman, Aniek C; Hayes, Ben J; Calus, Mario P L
2017-10-30
Genomic evaluation is used to predict direct genomic values (DGV) for selection candidates in breeding programs, but also to estimate allele substitution effects (ASE) of single nucleotide polymorphisms (SNPs). Scaling of allele counts influences the estimated ASE, because scaling of allele counts results in less shrinkage towards the mean for low minor allele frequency (MAF) variants. Scaling may become relevant for estimating ASE as more low MAF variants will be used in genomic evaluations. We show the impact of scaling on estimates of ASE using real data and a theoretical framework, and in terms of power, model fit and predictive performance. In a dairy cattle dataset with 630 K SNP genotypes, the correlation between DGV for stature from a random regression model using centered allele counts (RRc) and centered and scaled allele counts (RRcs) was 0.9988, whereas the overall correlation between ASE using RRc and RRcs was 0.27. The main difference in ASE between both methods was found for SNPs with a MAF lower than 0.01. Both the ratio (ASE from RRcs/ASE from RRc) and the regression coefficient (regression of ASE from RRcs on ASE from RRc) were much higher than 1 for low MAF SNPs. Derived equations showed that scenarios with a high heritability, a large number of individuals and a small number of variants have lower ratios between ASE from RRc and RRcs. We also investigated the optimal scaling parameter [from - 1 (RRcs) to 0 (RRc) in steps of 0.1] in the bovine stature dataset. We found that the log-likelihood was maximized with a scaling parameter of - 0.8, while the mean squared error of prediction was minimized with a scaling parameter of - 1, i.e., RRcs. Large differences in estimated ASE were observed for low MAF SNPs when allele counts were scaled or not scaled because there is less shrinkage towards the mean for scaled allele counts. We derived a theoretical framework that shows that the difference in ASE due to shrinkage is heavily influenced by the power of the data. Increasing the power results in smaller differences in ASE whether allele counts are scaled or not.
Direct Solve of Electrically Large Integral Equations for Problem Sizes to 1M Unknowns
NASA Technical Reports Server (NTRS)
Shaeffer, John
2008-01-01
Matrix methods for solving integral equations via direct solve LU factorization are presently limited to weeks to months of very expensive supercomputer time for problems sizes of several hundred thousand unknowns. This report presents matrix LU factor solutions for electromagnetic scattering problems for problem sizes to one million unknowns with thousands of right hand sides that run in mere days on PC level hardware. This EM solution is accomplished by utilizing the numerical low rank nature of spatially blocked unknowns using the Adaptive Cross Approximation for compressing the rank deficient blocks of the system Z matrix, the L and U factors, the right hand side forcing function and the final current solution. This compressed matrix solution is applied to a frequency domain EM solution of Maxwell's equations using standard Method of Moments approach. Compressed matrix storage and operations count leads to orders of magnitude reduction in memory and run time.
Germonpré, Peter; Papadopoulou, Virginie; Hemelryck, Walter; Obeid, Georges; Lafère, Pierre; Eckersley, Robert J; Tang, Meng-Xing; Balestra, Costantino
2014-03-01
'Decompression stress' is commonly evaluated by scoring circulating bubble numbers post dive using Doppler or cardiac echography. This information may be used to develop safer decompression algorithms, assuming that the lower the numbers of venous gas emboli (VGE) observed post dive, the lower the statistical risk of decompression sickness (DCS). Current echocardiographic evaluation of VGE, using the Eftedal and Brubakk method, has some disadvantages as it is less well suited for large-scale evaluation of recreational diving profiles. We propose and validate a new 'frame-based' VGE-counting method which offers a continuous scale of measurement. Nine 'raters' of varying familiarity with echocardiography were asked to grade 20 echocardiograph recordings using both the Eftedal and Brubakk grading and the new 'frame-based' counting method. They were also asked to count the number of bubbles in 50 still-frame images, some of which were randomly repeated. A Wilcoxon Spearman ρ calculation was used to assess test-retest reliability of each rater for the repeated still frames. For the video images, weighted kappa statistics, with linear and quadratic weightings, were calculated to measure agreement between raters for the Eftedal and Brubakk method. Bland-Altman plots and intra-class correlation coefficients were used to measure agreement between raters for the frame-based counting method. Frame-based counting showed a better inter-rater agreement than the Eftedal and Brubakk grading, even with relatively inexperienced assessors, and has good intra- and inter-rater reliability. Frame-based bubble counting could be used to evaluate post-dive decompression stress, and offers possibilities for computer-automated algorithms to allow near-real-time counting.
Detecting swift fox: Smoked-plate scent stations versus spotlighting
Daniel W. Uresk; Kieth E. Severson; Jody Javersak
2003-01-01
We compared two methods of detecting presence of swift fox: smoked-plate scent stations and spotlight counts. Tracks were counted on ten 1-mile (1.6-km) transects with bait/tracking plate stations every 0.1 mile (0.16 km). Vehicle spotlight counts were conducted on the same transects. Methods were compared with Spearman's rank order correlation. Repeated measures...
Consequences count: against absolutism at the end of life.
Snelling, Paul C
2004-05-01
There has been a considerable amount of debate in the nursing literature about euthanasia, and especially the distinctions between acts and omissions, and killing and letting die. These distinctions are required by opponents of euthanasia to justify allowing some cases of passive euthanasia while forbidding all cases of active euthanasia. This paper adds to the debate by arguing that the position that absolutely forbids euthanasia is theoretically inconsistent. The paper first considers the place of moral theory in analysing moral problems, within the framework of the principles of biomedical ethics. It is argued that despite a moral pluralism that operates in many areas, the legal status of euthanasia is based upon an absolute deontological position against deliberate killing, which cannot be overridden by appeals to favourable consequences. In order that certain forms of passive euthanasia can be allowed, this position allows distinctions within three pairs of concepts--acts and omissions, killing and letting die, and ordinary and extraordinary means. A further method of justifying certain actions near the end of life is the doctrine of double effect. These paired concepts and the doctrine of double effect are analysed with special reference to their consequences. The application of the doctrine of double effect and the three distinctions relies on consideration of their consequences, allowing in practice what in theory is denied. This is important because it weakens the absolute case against euthanasia, which disallows any direct consequentialist appeal. If consequences count in the application of the doctrine and the distinctions, then they should also count directly prior to their application. This strengthens the argument for active euthanasia in certain cases.
Alternative industrial carbon emissions benchmark based on input-output analysis
NASA Astrophysics Data System (ADS)
Han, Mengyao; Ji, Xi
2016-12-01
Some problems exist in the current carbon emissions benchmark setting systems. The primary consideration for industrial carbon emissions standards highly relate to direct carbon emissions (power-related emissions) and only a portion of indirect emissions are considered in the current carbon emissions accounting processes. This practice is insufficient and may cause double counting to some extent due to mixed emission sources. To better integrate and quantify direct and indirect carbon emissions, an embodied industrial carbon emissions benchmark setting method is proposed to guide the establishment of carbon emissions benchmarks based on input-output analysis. This method attempts to link direct carbon emissions with inter-industrial economic exchanges and systematically quantifies carbon emissions embodied in total product delivery chains. The purpose of this study is to design a practical new set of embodied intensity-based benchmarks for both direct and indirect carbon emissions. Beijing, at the first level of carbon emissions trading pilot schemes in China, plays a significant role in the establishment of these schemes and is chosen as an example in this study. The newly proposed method tends to relate emissions directly to each responsibility in a practical way through the measurement of complex production and supply chains and reduce carbon emissions from their original sources. This method is expected to be developed under uncertain internal and external contexts and is further expected to be generalized to guide the establishment of industrial benchmarks for carbon emissions trading schemes in China and other countries.
Newell, Felicity L.; Sheehan, James; Wood, Petra Bohall; Rodewald, Amanda D.; Buehler, David A.; Keyser, Patrick D.; Larkin, Jeffrey L.; Beachy, Tiffany A.; Bakermans, Marja H.; Boves, Than J.; Evans, Andrea; George, Gregory A.; McDermott, Molly E.; Perkins, Kelly A.; White, Matthew; Wigley, T. Bently
2013-01-01
Point counts are commonly used to assess changes in bird abundance, including analytical approaches such as distance sampling that estimate density. Point-count methods have come under increasing scrutiny because effects of detection probability and field error are difficult to quantify. For seven forest songbirds, we compared fixed-radii counts (50 m and 100 m) and density estimates obtained from distance sampling to known numbers of birds determined by territory mapping. We applied point-count analytic approaches to a typical forest management question and compared results to those obtained by territory mapping. We used a before–after control impact (BACI) analysis with a data set collected across seven study areas in the central Appalachians from 2006 to 2010. Using a 50-m fixed radius, variance in error was at least 1.5 times that of the other methods, whereas a 100-m fixed radius underestimated actual density by >3 territories per 10 ha for the most abundant species. Distance sampling improved accuracy and precision compared to fixed-radius counts, although estimates were affected by birds counted outside 10-ha units. In the BACI analysis, territory mapping detected an overall treatment effect for five of the seven species, and effects were generally consistent each year. In contrast, all point-count methods failed to detect two treatment effects due to variance and error in annual estimates. Overall, our results highlight the need for adequate sample sizes to reduce variance, and skilled observers to reduce the level of error in point-count data. Ultimately, the advantages and disadvantages of different survey methods should be considered in the context of overall study design and objectives, allowing for trade-offs among effort, accuracy, and power to detect treatment effects.
An automated approach for annual layer counting in ice cores
NASA Astrophysics Data System (ADS)
Winstrup, M.; Svensson, A.; Rasmussen, S. O.; Winther, O.; Steig, E.; Axelrod, A.
2012-04-01
The temporal resolution of some ice cores is sufficient to preserve seasonal information in the ice core record. In such cases, annual layer counting represents one of the most accurate methods to produce a chronology for the core. Yet, manual layer counting is a tedious and sometimes ambiguous job. As reliable layer recognition becomes more difficult, a manual approach increasingly relies on human interpretation of the available data. Thus, much may be gained by an automated and therefore objective approach for annual layer identification in ice cores. We have developed a novel method for automated annual layer counting in ice cores, which relies on Bayesian statistics. It uses algorithms from the statistical framework of Hidden Markov Models (HMM), originally developed for use in machine speech recognition. The strength of this layer detection algorithm lies in the way it is able to imitate the manual procedures for annual layer counting, while being based on purely objective criteria for annual layer identification. With this methodology, it is possible to determine the most likely position of multiple layer boundaries in an entire section of ice core data at once. It provides a probabilistic uncertainty estimate of the resulting layer count, hence ensuring a proper treatment of ambiguous layer boundaries in the data. Furthermore multiple data series can be incorporated to be used at once, hence allowing for a full multi-parameter annual layer counting method similar to a manual approach. In this study, the automated layer counting algorithm has been applied to data from the NGRIP ice core, Greenland. The NGRIP ice core has very high temporal resolution with depth, and hence the potential to be dated by annual layer counting far back in time. In previous studies [Andersen et al., 2006; Svensson et al., 2008], manual layer counting has been carried out back to 60 kyr BP. A comparison between the counted annual layers based on the two approaches will be presented and their differences discussed. Within the estimated uncertainties, the two methodologies agree. This shows the potential for a fully automated annual layer counting method to be operational for data sections where the annual layering is unknown.
Patrick, T E; Goodwin, T L; Collins, J A; Wyche, R C; Love, B E
1972-04-01
A comparison of two types of scalders was conducted to determine their effectiveness in reducing bacterial contamination of poultry carcasses. A conventional hot-water scalder and a prototype model of a steam scalder were tested under commercial conditions. Total plate counts from steam-scalded birds were significantly lower than the counts of water-scalded birds immediately after scalding and again after picking. No differences in the two methods could be found after chilling. Coliform counts from steam-scalded birds were significantly lower than the counts from water-scalded birds immediately after scalding. No significant differences in coliform counts were detected when the two scald methods were compared after defeathering and chilling.
ATP as a biomarker of viable microorganisms in clean-room facilities
NASA Technical Reports Server (NTRS)
Venkateswaran, Kasthuri; Hattori, Noriaki; La Duc, Myron T.; Kern, Roger
2003-01-01
A new firefly luciferase bioluminescence assay method that differentiates free extracellular ATP (dead cells, etc.) from intracellular ATP (viable microbes) was used to determine the viable microbial cleanliness of various clean-room facilities. For comparison, samples were taken from both clean-rooms, where the air was filtered to remove particles >0.5 microm, and ordinary rooms with unfiltered air. The intracellular ATP was determined after enzymatically degrading the sample's free ATP. Also for comparison, cultivable microbial populations were counted on nutrient-rich trypticase soy agar (TSA) plates. Both the cultivable and ATP-based determinations indicate that the microbial burden was lower in clean-room facilities than in ordinary rooms. However, there was no direct correlation between the two sets of measurements because the two assays measured very different populations. A large fraction of the samples yielded no colony formers on TSA, but were positive for intracellular ATP. Subsequently, genomic DNA was isolated directly from selected samples and 16S rDNA fragments were cloned and sequenced, identifying nearest neighbors, many of which are known to be noncultivable in the media employed. It was concluded that viable microbial contamination can be reliably monitored by measurement of intracellular ATP, and that this method may be considered superior to cultivable colony counts due to its speed and its ability to report the presence of viable but noncultivable organisms. When the detection of nonviable microbes is of interest, the ATP assay can be supplemented with DNA analysis.
ATP as a biomarker of viable microorganisms in clean-room facilities.
Venkateswaran, Kasthuri; Hattori, Noriaki; La Duc, Myron T; Kern, Roger
2003-03-01
A new firefly luciferase bioluminescence assay method that differentiates free extracellular ATP (dead cells, etc.) from intracellular ATP (viable microbes) was used to determine the viable microbial cleanliness of various clean-room facilities. For comparison, samples were taken from both clean-rooms, where the air was filtered to remove particles >0.5 microm, and ordinary rooms with unfiltered air. The intracellular ATP was determined after enzymatically degrading the sample's free ATP. Also for comparison, cultivable microbial populations were counted on nutrient-rich trypticase soy agar (TSA) plates. Both the cultivable and ATP-based determinations indicate that the microbial burden was lower in clean-room facilities than in ordinary rooms. However, there was no direct correlation between the two sets of measurements because the two assays measured very different populations. A large fraction of the samples yielded no colony formers on TSA, but were positive for intracellular ATP. Subsequently, genomic DNA was isolated directly from selected samples and 16S rDNA fragments were cloned and sequenced, identifying nearest neighbors, many of which are known to be noncultivable in the media employed. It was concluded that viable microbial contamination can be reliably monitored by measurement of intracellular ATP, and that this method may be considered superior to cultivable colony counts due to its speed and its ability to report the presence of viable but noncultivable organisms. When the detection of nonviable microbes is of interest, the ATP assay can be supplemented with DNA analysis.
Black, James; Gerdtz, Marie; Nicholson, Pat; Crellin, Dianne; Browning, Laura; Simpson, Julie; Bell, Lauren; Santamaria, Nick
2015-05-01
Respiratory rate is an important sign that is commonly either not recorded or recorded incorrectly. Mobile phone ownership is increasing even in resource-poor settings. Phone applications may improve the accuracy and ease of counting of respiratory rates. The study assessed the reliability and initial users' impressions of four mobile phone respiratory timer approaches, compared to a 60-second count by the same participants. Three mobile applications (applying four different counting approaches plus a standard 60-second count) were created using the Java Mobile Edition and tested on Nokia C1-01 phones. Apart from the 60-second timer application, the others included a counter based on the time for ten breaths, and three based on the time interval between breaths ('Once-per-Breath', in which the user presses for each breath and the application calculates the rate after 10 or 20 breaths, or after 60s). Nursing and physiotherapy students used the applications to count respiratory rates in a set of brief video recordings of children with different respiratory illnesses. Limits of agreement (compared to the same participant's standard 60-second count), intra-class correlation coefficients and standard errors of measurement were calculated to compare the reliability of the four approaches, and a usability questionnaire was completed by the participants. There was considerable variation in the counts, with large components of the variation related to the participants and the videos, as well as the methods. None of the methods was entirely reliable, with no limits of agreement better than -10 to +9 breaths/min. Some of the methods were superior to the others, with ICCs from 0.24 to 0.92. By ICC the Once-per-Breath 60-second count and the Once-per-Breath 20-breath count were the most consistent, better even than the 60-second count by the participants. The 10-breath approaches performed least well. Users' initial impressions were positive, with little difference between the applications found. This study provides evidence that applications running on simple phones can be used to count respiratory rates in children. The Once-per-Breath methods are the most reliable, outperforming the 60-second count. For children with raised respiratory rates the 20-breath version of the Once-per-Breath method is faster, so it is a more suitable option where health workers are under time pressure. Copyright © 2015 Elsevier Ltd. All rights reserved.
Performance evaluation of the new hematology analyzer Sysmex XN-series.
Seo, J Y; Lee, S-T; Kim, S-H
2015-04-01
The Sysmex XN-series is a new automated hematology analyzer designed to improve the accuracy of cell counts and the specificity of the flagging events. The basic characteristics and the performance of new measurement channels of the XN were evaluated and compared with the Sysmex XE-2100 and the manual method. Fluorescent platelet count (PLT-F) was compared with the flow cytometric method. The low WBC mode and body fluid mode were also evaluated. For workflow analysis, 1005 samples were analyzed on both the XN and the XE-2100, and manual review rates were compared. All parameters measured by the XN correlated well with the XE-2100. PLT-F showed better correlation with the flow cytometric method (r(2) = 0.80) compared with optical platelet count (r(2) = 0.73) for platelet counts <70 × 10(9) /L. The low WBC mode reported accurate leukocyte differentials for samples with a WBC count <0.5 × 10(9) /L. Relatively good correlation was found for WBC counts between the manual method and the body fluid mode (r = 0.88). The XN made less flags than the XE-2100, while the sensitivities of both instruments were comparable. The XN provided reliable results on low cell counts, as well as reduced manual blood film reviews, while maintaining a proper level of diagnostic sensitivity. © 2014 John Wiley & Sons Ltd.
Learning linear transformations between counting-based and prediction-based word embeddings
Hayashi, Kohei; Kawarabayashi, Ken-ichi
2017-01-01
Despite the growing interest in prediction-based word embedding learning methods, it remains unclear as to how the vector spaces learnt by the prediction-based methods differ from that of the counting-based methods, or whether one can be transformed into the other. To study the relationship between counting-based and prediction-based embeddings, we propose a method for learning a linear transformation between two given sets of word embeddings. Our proposal contributes to the word embedding learning research in three ways: (a) we propose an efficient method to learn a linear transformation between two sets of word embeddings, (b) using the transformation learnt in (a), we empirically show that it is possible to predict distributed word embeddings for novel unseen words, and (c) empirically it is possible to linearly transform counting-based embeddings to prediction-based embeddings, for frequent words, different POS categories, and varying degrees of ambiguities. PMID:28926629
NASA Astrophysics Data System (ADS)
Liu, Sijia; Sa, Ruhan; Maguire, Orla; Minderman, Hans; Chaudhary, Vipin
2015-03-01
Cytogenetic abnormalities are important diagnostic and prognostic criteria for acute myeloid leukemia (AML). A flow cytometry-based imaging approach for FISH in suspension (FISH-IS) was established that enables the automated analysis of several log-magnitude higher number of cells compared to the microscopy-based approaches. The rotational positioning can occur leading to discordance between spot count. As a solution of counting error from overlapping spots, in this study, a Gaussian Mixture Model based classification method is proposed. The Akaike information criterion (AIC) and Bayesian information criterion (BIC) of GMM are used as global image features of this classification method. Via Random Forest classifier, the result shows that the proposed method is able to detect closely overlapping spots which cannot be separated by existing image segmentation based spot detection methods. The experiment results show that by the proposed method we can obtain a significant improvement in spot counting accuracy.
Kinoshita, S; Suzuki, T; Yamashita, S; Muramatsu, T; Ide, M; Dohi, Y; Nishimura, K; Miyamae, T; Yamamoto, I
1992-01-01
A new radionuclide technique for the calculation of left ventricular (LV) volume by the first-pass (FP) method was developed and examined. Using a semi-geometric count-based method, the LV volume can be measured by the following equation: CV = CM/(L/d). V = (CT/CV) x d3 = (CT/CM) x L x d2. (V = LV volume, CV = voxel count, CM = the maximum LV count, CT = the total LV count, L = LV depth where the maximum count was obtained, and d = pixel size.) This theorem was applied to FP LV images obtained in the 30-degree right anterior oblique position. Frame-mode acquisition was performed and the LV end-diastolic maximum count and total count were obtained. The maximum LV depth was obtained as the maximum width of the LV on the FP end-diastolic image, using the assumption that the LV cross-section is circular. These values were substituted in the above equation and the LV end-diastolic volume (FP-EDV) was calculated. A routine equilibrium (EQ) study was done, and the end-diastolic maximum count and total count were obtained. The LV maximum depth was measured on the FP end-diastolic frame, as the maximum length of the LV image. Using these values, the EQ-EDV was calculated and the FP-EDV was compared to the EQ-EDV. The correlation coefficient for these two values was r = 0.96 (n = 23, p less than 0.001), and the standard error of the estimated volume was 10 ml.(ABSTRACT TRUNCATED AT 250 WORDS)
Tracking and people counting using Particle Filter Method
NASA Astrophysics Data System (ADS)
Sulistyaningrum, D. R.; Setiyono, B.; Rizky, M. S.
2018-03-01
In recent years, technology has developed quite rapidly, especially in the field of object tracking. Moreover, if the object under study is a person and the number of people a lot. The purpose of this research is to apply Particle Filter method for tracking and counting people in certain area. Tracking people will be rather difficult if there are some obstacles, one of which is occlusion. The stages of tracking and people counting scheme in this study include pre-processing, segmentation using Gaussian Mixture Model (GMM), tracking using particle filter, and counting based on centroid. The Particle Filter method uses the estimated motion included in the model used. The test results show that the tracking and people counting can be done well with an average accuracy of 89.33% and 77.33% respectively from six videos test data. In the process of tracking people, the results are good if there is partial occlusion and no occlusion
Precision wildlife monitoring using unmanned aerial vehicles
NASA Astrophysics Data System (ADS)
Hodgson, Jarrod C.; Baylis, Shane M.; Mott, Rowan; Herrod, Ashley; Clarke, Rohan H.
2016-03-01
Unmanned aerial vehicles (UAVs) represent a new frontier in environmental research. Their use has the potential to revolutionise the field if they prove capable of improving data quality or the ease with which data are collected beyond traditional methods. We apply UAV technology to wildlife monitoring in tropical and polar environments and demonstrate that UAV-derived counts of colony nesting birds are an order of magnitude more precise than traditional ground counts. The increased count precision afforded by UAVs, along with their ability to survey hard-to-reach populations and places, will likely drive many wildlife monitoring projects that rely on population counts to transition from traditional methods to UAV technology. Careful consideration will be required to ensure the coherence of historic data sets with new UAV-derived data and we propose a method for determining the number of duplicated (concurrent UAV and ground counts) sampling points needed to achieve data compatibility.
Comparison of direct and indirect methods of measuring airborne chrysotile fibre concentration.
Eypert-Blaison, Celine; Veissiere, Sylvie; Rastoix, Olivier; Kauffer, Edmond
2010-01-01
Transmission electron microscopy observations most frequently form a basis for estimating asbestos fibre concentration in the environment and in buildings with asbestos-containing materials. Sampled fibres can be transferred to microscope grids by applying either a direct [ISO (1995) Draft International ISO/DIS 10312. Ambient air. Determination of asbestos fibres. Direct transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] or an indirect [AFNOR (1996) Détermination de la concentration en fibres d'amiante par microscopie électronique à transmission-Méthode indirecte. Cedex, France: AFNOR, p. 42; ISO (1997) Draft International ISO/DIS 13794. Ambient air. Determination of asbestos fibres. Indirect-transfer transmission electron microscopy procedure. Geneva, Switzerland: International Standardization Organization] method. In the latter case, ISO Standard 13794 recommends filtering calcination residues either on a polycarbonate (PC) filter (PC indirect method) or on a cellulose ester (CE) membrane (CE indirect method). The PC indirect method requires that fibres deposited on a PC filter be covered by a carbon layer, whereas in the CE indirect method, the CE membrane has to be directly processed using a method described in ISO Standard 10312. The purpose of this study was to compare results obtained using, on the one hand, direct preparation methods and, on the other hand, PC indirect or CE indirect methods, for counting asbestos fibres deposited on filters as a result of liquid filtration or air sampling. In direct method-based preparation, we observed that an etching time of 6-14 min does not affect the measured densities, except for fibres <1 microm deposited by liquid filtration. Moreover, in all cases, the direct method gives higher densities than the PC indirect method because of possible fibre disappearance when using the carbon evaporator implemented in the PC indirect method. The CE membrane used for sample preparation in the CE indirect method is collapsed prior to passing it through the carbon evaporator, so the fibres are less likely to disappear at this stage. We then note that the resulting fibre densities for chrysotile-loaded filters prepared using the direct method are close to those obtained with filters prepared using the CE indirect method. Our study therefore shows that, under the implemented experimental conditions, the PC and CE indirect preparation methods described in ISO Standard 13794 are not equivalent.
Yuste, J; Fung, D Y C
2004-02-01
Pasteurized apple juice with nisin (0, 25, 50, 100, and 200 ppm, wt/vol) and cinnamon (0 and 0.3%, wt/vol) was inoculated with Salmonella Typhimurium and Escherichia coli O157:H7 at 10(4) CFU/ml and stored at 5 and 20 degrees C. Counts on tryptic soy agar (TSA), selective medium (xylose Lysine desoxycholate agar for Salmonella Typhimurium, and MacConkey sorbitol agar for E. coli O157:H7), and thin agar layer (TAL) were determined at 1 h and 1, 3, 7, and 14 days. The TAL method (selective medium overlaid with TSA) was used for recovery of sublethally injured cells. The pathogens were gradually inactivated by the acidic pH of apple juice. Nisin and cinnamon greatly contributed to the inactivation. The killing effect was more marked at 20 degrees C, with counts in all treated samples being undetectable by direct plating in 3 days for Salmonella Typhimurium and 7 days for E. coli O157:H7. Thus, several factors influenced the decrease in counts: low pH, addition of nisin and cinnamon, and storage temperature. The TAL method was as effective as TSA in recovering injured cells of the pathogens. The combination of nisin and cinnamon accelerates death of Salmonella Typhimurium and E. coli O157:H7 in apple juice and so enhances the safety of the product.
Mothers of Obese Children Use More Direct Imperatives to Restrict Eating.
Pesch, Megan H; Miller, Alison L; Appugliese, Danielle P; Rosenblum, Katherine L; Lumeng, Julie C
2018-04-01
To examine the association of mother and child characteristics with use of direct imperatives to restrict eating. A total of 237 mother-child dyads (mean child age, 70.9 months) participated in a video-recorded, laboratory-standardized eating protocol with 2 large portions of cupcakes. Videos were reliably coded for counts of maternal direct imperatives to restrict children's eating. Anthropometrics were measured. Regression models tested the association of participant characteristics with counts of direct imperatives. Child obese weight status and maternal white non-Hispanic race/ethnicity were associated with greater levels of direct imperatives to restrict eating (p = .0001 and .0004, respectively). Mothers of obese children may be using more direct imperatives to restrict eating so as to achieve behavioral compliance to decrease their child's food intake. Future work should consider the effects direct imperatives have on children's short- and long-term eating behaviors and weight gain trajectories. Copyright © 2017 Society for Nutrition Education and Behavior. Published by Elsevier Inc. All rights reserved.
Double-survey estimates of bald eagle populations in Oregon
Anthony, R.G.; Garrett, Monte G.; Isaacs, F.B.
1999-01-01
The literature on abundance of birds of prey is almost devoid of population estimates with statistical rigor. Therefore, we surveyed bald eagle (Haliaeetus leucocephalus) populations on the Crooked and lower Columbia rivers of Oregon and used the double-survey method to estimate populations and sighting probabilities for different survey methods (aerial, boat, vehicle) and bald eagle ages (adults vs. subadults). Sighting probabilities were consistently 20%. The results revealed variable and negative bias (percent relative bias = -9 to -70%) of direct counts and emphasized the importance of estimating populations where some measure of precision and ability to conduct inference tests are available. We recommend use of the double-survey method to estimate abundance of bald eagle populations and other raptors in open habitats.
Tomasino, Stephen F; Fiumara, Rebecca M; Cottrill, Michele P
2006-01-01
The AOAC Use-Dilution methods do not provide procedures to enumerate the test microbe on stainless steel carriers (penicylinders) or guidance on the expected target populations of the test microbe (i.e., a performance standard). This report describes the procedures used by the U.S. Environmental Protection Agency to enumerate the test microbe (carrier counts) associated with conducting the Use-Dilution method with Staphylococcus aureus (Method 955.15) and Pseudomonas aeruginosa (Method 964.02) and the examination of historical data. The carrier count procedure involves the random selection of carriers, shearing bacterial cells from the carrier surface through sonication, and plating of serially diluted inoculum on trypticase soy agar. For each Use-Dilution test conducted, the official AOAC method was strictly followed for carrier preparation, culture initiation, test culture preparation, and carrier inoculation steps. Carrier count data from 78 Use-Dilution tests conducted over a 6-year period were compiled and analyzed. A mean carrier count of 6.6 logs (approximately 4.0 x 10(6) colony-forming units/carrier) was calculated for both S. aureus and P. aeruginosa. Of the mean values, 95% fell within +/- 2 repeatability standard deviations. The enumeration procedure and target carrier counts are desirable for standardizing the Use-Dilution methods, increasing their reproducibility, and ensuring the quality of the data.
How many fish in a tank? Constructing an automated fish counting system by using PTV analysis
NASA Astrophysics Data System (ADS)
Abe, S.; Takagi, T.; Takehara, K.; Kimura, N.; Hiraishi, T.; Komeyama, K.; Torisawa, S.; Asaumi, S.
2017-02-01
Because escape from a net cage and mortality are constant problems in fish farming, health control and management of facilities are important in aquaculture. In particular, the development of an accurate fish counting system has been strongly desired for the Pacific Bluefin tuna farming industry owing to the high market value of these fish. The current fish counting method, which involves human counting, results in poor accuracy; moreover, the method is cumbersome because the aquaculture net cage is so large that fish can only be counted when they move to another net cage. Therefore, we have developed an automated fish counting system by applying particle tracking velocimetry (PTV) analysis to a shoal of swimming fish inside a net cage. In essence, we treated the swimming fish as tracer particles and estimated the number of fish by analyzing the corresponding motion vectors. The proposed fish counting system comprises two main components: image processing and motion analysis, where the image-processing component abstracts the foreground and the motion analysis component traces the individual's motion. In this study, we developed a Region Extraction and Centroid Computation (RECC) method and a Kalman filter and Chi-square (KC) test for the two main components. To evaluate the efficiency of our method, we constructed a closed system, placed an underwater video camera with a spherical curved lens at the bottom of the tank, and recorded a 360° view of a swimming school of Japanese rice fish (Oryzias latipes). Our study showed that almost all fish could be abstracted by the RECC method and the motion vectors could be calculated by the KC test. The recognition rate was approximately 90% when more than 180 individuals were observed within the frame of the video camera. These results suggest that the presented method has potential application as a fish counting system for industrial aquaculture.
Villarreal, Martha Lissete Morales; Padilha, Marina; Vieira, Antonio Diogo Silva; Franco, Bernadette Dora Gombossy de Melo; Martinez, Rafael Chacon Ruiz; Saad, Susana Marta Isay
2013-01-01
Species-specific Quantitative Real Time PCR (qPCR) alone and combined with the use of propidium monoazide (PMA) were used along with the plate count method to evaluate the survival of the probiotic strains Lactobacillus acidophilus La-5 and Bifidobacterium animalis subsp. lactis Bb-12, and the bacteriocinogenic and potentially probiotic strain Lactobacillus sakei subsp. sakei 2a in synbiotic (F1) and probiotic (F2) petit-suisse cheeses exposed throughout shelf-life to in vitro simulated gastrointestinal tract conditions. The three strains studied showed a reduction in their viability after the 6 h assay. Bb-12 displayed the highest survival capacity, above 72.6 and 74.6% of the initial populations, respectively, by plate count and PMA-qPCR, maintaining population levels in the range or above 6 log CFU/g. The prebiotic mix of inulin and FOS did not offer any additional protection for the strains against the simulated gastrointestinal environment. The microorganisms' populations were comparable among the three methods at the initial time of the assay, confirming the presence of mainly viable and culturable cells. However, with the intensification of the stress induced throughout the various stages of the in vitro test, the differences among the methods increased. The qPCR was not a reliable enumeration method for the quantification of intact bacterial populations, mixed with large numbers of injured and dead bacteria, as confirmed by the scanning electron microscopy results. Furthermore, bacteria plate counts were much lower (P<0.05) than with the PMA-qPCR method, suggesting the accumulation of stressed or dead microorganisms unable to form colonies. The use of PMA overcame the qPCR inability to differentiate between dead and alive cells. The combination of PMA and species-specific qPCR in this study allowed a quick and unequivocal way of enumeration of viable closely related species incorporated into probiotic and synbiotic petit-suisse cheeses and under stress conditions. PMID:24358142
Methods of detecting and counting raptors: A review
Fuller, M.R.; Mosher, J.A.; Ralph, C. John; Scott, J. Michael
1981-01-01
Most raptors are wide-ranging, secretive, and occur at relatively low densities. These factors, in conjunction with the nocturnal activity of owls, cause the counting of raptors by most standard census and survey efforts to be very time consuming and expensive. This paper reviews the most common methods of detecting and counting raptors. It is hoped that it will be of use to the ever-increasing number of biologists, land-use planners, and managers that must determine the occurrence, density, or population dynamics of raptors. Road counts of fixed station or continuous transect design are often used to sample large areas. Detection of spontaneous or elicited vocalizations, especially those of owls, provides a means of detecting and estimating raptor numbers. Searches for nests are accomplished from foot surveys, observations from automobiles and boats, or from aircraft when nest structures are conspicuous (e.g., Osprey). Knowledge of nest habitat, historic records, and inquiries of local residents are useful for locating nests. Often several of these techniques are combined to help find nest sites. Aerial searches have also been used to locate or count large raptors (e.g., eagles), or those that may be conspicuous in open habitats (e.g., tundra). Counts of birds entering or leaving nest colonies or colonial roosts have been attempted on a limited basis. Results from Christmas Bird Counts have provided an index of the abundance of some species. Trapping and banding generally has proven to be an inefficient method of detecting raptors or estimating their populations. Concentrations of migrants at strategically located points around the world afford the best opportunity to count many rap tors in a relatively short period of time, but the influence of many unquantified variables has inhibited extensive interpretation of these counts. Few data exist to demonstrate the effectiveness of these methods. We believe more research on sampling techniques, rather than complete counts or intensive searches, will provide adequate yet affordable estimates of raptor numbers in addition to providing methods for detecting the presence of raptors on areas of interest to researchers and managers.
Comparison of point-of-care methods for preparation of platelet concentrate (platelet-rich plasma).
Weibrich, Gernot; Kleis, Wilfried K G; Streckbein, Philipp; Moergel, Maximilian; Hitzler, Walter E; Hafner, Gerd
2012-01-01
This study analyzed the concentrations of platelets and growth factors in platelet-rich plasma (PRP), which are likely to depend on the method used for its production. The cellular composition and growth factor content of platelet concentrates (platelet-rich plasma) produced by six different procedures were quantitatively analyzed and compared. Platelet and leukocyte counts were determined on an automatic cell counter, and analysis of growth factors was performed using enzyme-linked immunosorbent assay. The principal differences between the analyzed PRP production methods (blood bank method of intermittent flow centrifuge system/platelet apheresis and by the five point-of-care methods) and the resulting platelet concentrates were evaluated with regard to resulting platelet, leukocyte, and growth factor levels. The platelet counts in both whole blood and PRP were generally higher in women than in men; no differences were observed with regard to age. Statistical analysis of platelet-derived growth factor AB (PDGF-AB) and transforming growth factor β1 (TGF-β1) showed no differences with regard to age or gender. Platelet counts and TGF-β1 concentration correlated closely, as did platelet counts and PDGF-AB levels. There were only rare correlations between leukocyte counts and PDGF-AB levels, but comparison of leukocyte counts and PDGF-AB levels demonstrated certain parallel tendencies. TGF-β1 levels derive in substantial part from platelets and emphasize the role of leukocytes, in addition to that of platelets, as a source of growth factors in PRP. All methods of producing PRP showed high variability in platelet counts and growth factor levels. The highest growth factor levels were found in the PRP prepared using the Platelet Concentrate Collection System manufactured by Biomet 3i.
A conceptual guide to detection probability for point counts and other count-based survey methods
D. Archibald McCallum
2005-01-01
Accurate and precise estimates of numbers of animals are vitally needed both to assess population status and to evaluate management decisions. Various methods exist for counting birds, but most of those used with territorial landbirds yield only indices, not true estimates of population size. The need for valid density estimates has spawned a number of models for...
a Mapping Method of Slam Based on Look up Table
NASA Astrophysics Data System (ADS)
Wang, Z.; Li, J.; Wang, A.; Wang, J.
2017-09-01
In the last years several V-SLAM(Visual Simultaneous Localization and Mapping) approaches have appeared showing impressive reconstructions of the world. However these maps are built with far more than the required information. This limitation comes from the whole process of each key-frame. In this paper we present for the first time a mapping method based on the LOOK UP TABLE(LUT) for visual SLAM that can improve the mapping effectively. As this method relies on extracting features in each cell divided from image, it can get the pose of camera that is more representative of the whole key-frame. The tracking direction of key-frames is obtained by counting the number of parallax directions of feature points. LUT stored all mapping needs the number of cell corresponding to the tracking direction which can reduce the redundant information in the key-frame, and is more efficient to mapping. The result shows that a better map with less noise is build using less than one-third of the time. We believe that the capacity of LUT efficiently building maps makes it a good choice for the community to investigate in the scene reconstruction problems.
Gunetti, Monica; Castiglia, Sara; Rustichelli, Deborah; Mareschi, Katia; Sanavio, Fiorella; Muraro, Michela; Signorino, Elena; Castello, Laura; Ferrero, Ivana; Fagioli, Franca
2012-05-31
The quality and safety of advanced therapy products must be maintained throughout their production and quality control cycle to ensure their final use in patients. We validated the cell count method according to the International Conference on Harmonization of Technical Requirements for Registration of Pharmaceuticals for Human Use and European Pharmacopoeia, considering the tests' accuracy, precision, repeatability, linearity and range. As the cell count is a potency test, we checked accuracy, precision, and linearity, according to ICH Q2. Briefly our experimental approach was first to evaluate the accuracy of Fast Read 102® compared to the Bürker chamber. Once the accuracy of the alternative method was demonstrated, we checked the precision and linearity test only using Fast Read 102®. The data were statistically analyzed by average, standard deviation and coefficient of variation percentages inter and intra operator. All the tests performed met the established acceptance criteria of a coefficient of variation of less than ten percent. For the cell count, the precision reached by each operator had a coefficient of variation of less than ten percent (total cells) and under five percent (viable cells). The best range of dilution, to obtain a slope line value very similar to 1, was between 1:8 and 1:128. Our data demonstrated that the Fast Read 102® count method is accurate, precise and ensures the linearity of the results obtained in a range of cell dilution. Under our standard method procedures, this assay may thus be considered a good quality control method for the cell count as a batch release quality control test. Moreover, the Fast Read 102® chamber is a plastic, disposable device that allows a number of samples to be counted in the same chamber. Last but not least, it overcomes the problem of chamber washing after use and so allows a cell count in a clean environment such as that in a Cell Factory. In a good manufacturing practice setting the disposable cell counting devices will allow a single use of the count chamber they can then be thrown away, thus avoiding the waste disposal of vital dye (e.g. Trypan Blue) or lysing solution (e.g. Tuerk solution).
Crack image segmentation based on improved DBC method
NASA Astrophysics Data System (ADS)
Cao, Ting; Yang, Nan; Wang, Fengping; Gao, Ting; Wang, Weixing
2017-11-01
With the development of computer vision technology, crack detection based on digital image segmentation method arouses global attentions among researchers and transportation ministries. Since the crack always exhibits the random shape and complex texture, it is still a challenge to accomplish reliable crack detection results. Therefore, a novel crack image segmentation method based on fractal DBC (differential box counting) is introduced in this paper. The proposed method can estimate every pixel fractal feature based on neighborhood information which can consider the contribution from all possible direction in the related block. The block moves just one pixel every time so that it could cover all the pixels in the crack image. Unlike the classic DBC method which only describes fractal feature for the related region, this novel method can effectively achieve crack image segmentation according to the fractal feature of every pixel. The experiment proves the proposed method can achieve satisfactory results in crack detection.
Image-based spectral distortion correction for photon-counting x-ray detectors
Ding, Huanjun; Molloi, Sabee
2012-01-01
Purpose: To investigate the feasibility of using an image-based method to correct for distortions induced by various artifacts in the x-ray spectrum recorded with photon-counting detectors for their application in breast computed tomography (CT). Methods: The polyenergetic incident spectrum was simulated with the tungsten anode spectral model using the interpolating polynomials (TASMIP) code and carefully calibrated to match the x-ray tube in this study. Experiments were performed on a Cadmium-Zinc-Telluride (CZT) photon-counting detector with five energy thresholds. Energy bins were adjusted to evenly distribute the recorded counts above the noise floor. BR12 phantoms of various thicknesses were used for calibration. A nonlinear function was selected to fit the count correlation between the simulated and the measured spectra in the calibration process. To evaluate the proposed spectral distortion correction method, an empirical fitting derived from the calibration process was applied on the raw images recorded for polymethyl methacrylate (PMMA) phantoms of 8.7, 48.8, and 100.0 mm. Both the corrected counts and the effective attenuation coefficient were compared to the simulated values for each of the five energy bins. The feasibility of applying the proposed method to quantitative material decomposition was tested using a dual-energy imaging technique with a three-material phantom that consisted of water, lipid, and protein. The performance of the spectral distortion correction method was quantified using the relative root-mean-square (RMS) error with respect to the expected values from simulations or areal analysis of the decomposition phantom. Results: The implementation of the proposed method reduced the relative RMS error of the output counts in the five energy bins with respect to the simulated incident counts from 23.0%, 33.0%, and 54.0% to 1.2%, 1.8%, and 7.7% for 8.7, 48.8, and 100.0 mm PMMA phantoms, respectively. The accuracy of the effective attenuation coefficient of PMMA estimate was also improved with the proposed spectral distortion correction. Finally, the relative RMS error of water, lipid, and protein decompositions in dual-energy imaging was significantly reduced from 53.4% to 6.8% after correction was applied. Conclusions: The study demonstrated that dramatic distortions in the recorded raw image yielded from a photon-counting detector could be expected, which presents great challenges for applying the quantitative material decomposition method in spectral CT. The proposed semi-empirical correction method can effectively reduce these errors caused by various artifacts, including pulse pileup and charge sharing effects. Furthermore, rather than detector-specific simulation packages, the method requires a relatively simple calibration process and knowledge about the incident spectrum. Therefore, it may be used as a generalized procedure for the spectral distortion correction of different photon-counting detectors in clinical breast CT systems. PMID:22482608
A critical evaluation of a flow cytometer used for detecting enterococci in recreational waters.
King, Dawn N; Brenner, Kristen P; Rodgers, Mark R
2007-06-01
The current U. S. Environmental Protection Agency-approved method for enterococci (Method 1600) in recreational water is a membrane filter (MF) method that takes 24 hours to obtain results. If the recreational water is not in compliance with the standard, the risk of exposure to enteric pathogens may occur before the water is identified as hazardous. Because flow cytometry combined with specific fluorescent antibodies has the potential to be used as a rapid detection method for microorganisms, this technology was evaluated as a rapid, same-day method to detect enterococci in bathing beach waters. The flow cytometer chosen for this study was a laser microbial detection system designed to detect labeled antibodies. A comparison of MF counts with flow cytometry counts of enterococci in phosphate buffer and sterile-filtered recreational water showed good agreement between the two methods. However, when flow cytometry was used, the counts were several orders of magnitude higher than the MF counts with no correlation to Enterococcus spike concentrations. The unspiked sample controls frequently had higher counts than the samples spiked with enterococci. Particles within the spiked water samples were probably counted as target cells by the flow cytometer because of autofluorescence or non-specific adsorption of antibody and carryover to subsequent samples. For these reasons, this technology may not be suitable for enterococci detection in recreational waters. Improvements in research and instrument design that will eliminate high background and carryover may make this a viable technology in the
Brown, Steven G; Vaughn, David L; Roberts, Paul T
2017-11-01
As part of two separate studies aimed to characterize ambient pollutant concentrations at schools in urban areas, we compare black carbon and particle count measurements at Adcock Elementary in Las Vegas, NV (April-June 2013), and Hunter High School in the West Valley City area of greater Salt Lake City, UT (February 2012). Both schools are in urban environments, but Adcock Elementary is next to the U.S. 95 freeway. Black carbon (BC) concentrations were 13% higher at Adcock compared to Hunter, while particle count concentrations were 60% higher. When wind speeds were low-less than 2 m/sec-both BC and particle count concentrations were significantly higher at Adcock, while concentrations at Hunter did not have as strong a variation with wind speed. When wind speeds were less than 2 m/sec, emissions from the adjacent freeway greatly affected concentrations at Adcock, regardless of wind direction. At both sites, BC and particle count concentrations peaked in the morning during commute hours. At Adcock, particle count also peaked during midday or early afternoon, when BC was low and conditions were conducive to new particle formation. While this midday peak occurred at Adcock on roughly 45% of the measured days, it occurred on only about 25% of the days at Hunter, since conditions for particle formation (higher solar radiation, lower wind speeds, lower relative humidity) were more conducive at Adcock. Thus, children attending these schools are likely to be exposed to pollution peaks during school drop-off in the morning, when BC and particle count concentrations peak, and often again during lunchtime recess when particle count peaks again. Particle count concentrations at two schools were shown to typically be independent of BC or other pollutants. At a school in close proximity to a major freeway, particle count concentrations were high during the midday and when wind speeds were low, regardless of wind direction, showing a large area of effect from roadway emissions even when the school was not downwind of the roadway. At the second school, which sits in an urban neighborhood away from freeways, high particle counts occurred even though solar radiation was low during wintertime conditions, meaning that exposure to high particle counts can occur throughout the year.
Application of the backward extrapolation method to pulsed neutron sources
DOE Office of Scientific and Technical Information (OSTI.GOV)
Talamo, Alberto; Gohar, Yousry
We report particle detectors operated in pulse mode are subjected to the dead-time effect. When the average of the detector counts is constant over time, correcting for the dead-time effect is simple and can be accomplished by analytical formulas. However, when the average of the detector counts changes over time it is more difficult to take into account the dead-time effect. When a subcritical nuclear assembly is driven by a pulsed neutron source, simple analytical formulas cannot be applied to the measured detector counts to correct for the dead-time effect because of the sharp change of the detector counts overmore » time. This work addresses this issue by using the backward extrapolation method. The latter can be applied not only to a continuous (e.g. californium) external neutron source but also to a pulsed external neutron source (e.g. by a particle accelerator) driving a subcritical nuclear assembly. Finally, the backward extrapolation method allows to obtain from the measured detector counts both the dead-time value and the real detector counts.« less
Application of the backward extrapolation method to pulsed neutron sources
Talamo, Alberto; Gohar, Yousry
2017-09-23
We report particle detectors operated in pulse mode are subjected to the dead-time effect. When the average of the detector counts is constant over time, correcting for the dead-time effect is simple and can be accomplished by analytical formulas. However, when the average of the detector counts changes over time it is more difficult to take into account the dead-time effect. When a subcritical nuclear assembly is driven by a pulsed neutron source, simple analytical formulas cannot be applied to the measured detector counts to correct for the dead-time effect because of the sharp change of the detector counts overmore » time. This work addresses this issue by using the backward extrapolation method. The latter can be applied not only to a continuous (e.g. californium) external neutron source but also to a pulsed external neutron source (e.g. by a particle accelerator) driving a subcritical nuclear assembly. Finally, the backward extrapolation method allows to obtain from the measured detector counts both the dead-time value and the real detector counts.« less
Clustering method for counting passengers getting in a bus with single camera
NASA Astrophysics Data System (ADS)
Yang, Tao; Zhang, Yanning; Shao, Dapei; Li, Ying
2010-03-01
Automatic counting of passengers is very important for both business and security applications. We present a single-camera-based vision system that is able to count passengers in a highly crowded situation at the entrance of a traffic bus. The unique characteristics of the proposed system include, First, a novel feature-point-tracking- and online clustering-based passenger counting framework, which performs much better than those of background-modeling-and foreground-blob-tracking-based methods. Second, a simple and highly accurate clustering algorithm is developed that projects the high-dimensional feature point trajectories into a 2-D feature space by their appearance and disappearance times and counts the number of people through online clustering. Finally, all test video sequences in the experiment are captured from a real traffic bus in Shanghai, China. The results show that the system can process two 320×240 video sequences at a frame rate of 25 fps simultaneously, and can count passengers reliably in various difficult scenarios with complex interaction and occlusion among people. The method achieves high accuracy rates up to 96.5%.
No Control Genes Required: Bayesian Analysis of qRT-PCR Data
Matz, Mikhail V.; Wright, Rachel M.; Scott, James G.
2013-01-01
Background Model-based analysis of data from quantitative reverse-transcription PCR (qRT-PCR) is potentially more powerful and versatile than traditional methods. Yet existing model-based approaches cannot properly deal with the higher sampling variances associated with low-abundant targets, nor do they provide a natural way to incorporate assumptions about the stability of control genes directly into the model-fitting process. Results In our method, raw qPCR data are represented as molecule counts, and described using generalized linear mixed models under Poisson-lognormal error. A Markov Chain Monte Carlo (MCMC) algorithm is used to sample from the joint posterior distribution over all model parameters, thereby estimating the effects of all experimental factors on the expression of every gene. The Poisson-based model allows for the correct specification of the mean-variance relationship of the PCR amplification process, and can also glean information from instances of no amplification (zero counts). Our method is very flexible with respect to control genes: any prior knowledge about the expected degree of their stability can be directly incorporated into the model. Yet the method provides sensible answers without such assumptions, or even in the complete absence of control genes. We also present a natural Bayesian analogue of the “classic” analysis, which uses standard data pre-processing steps (logarithmic transformation and multi-gene normalization) but estimates all gene expression changes jointly within a single model. The new methods are considerably more flexible and powerful than the standard delta-delta Ct analysis based on pairwise t-tests. Conclusions Our methodology expands the applicability of the relative-quantification analysis protocol all the way to the lowest-abundance targets, and provides a novel opportunity to analyze qRT-PCR data without making any assumptions concerning target stability. These procedures have been implemented as the MCMC.qpcr package in R. PMID:23977043
Tutorial on Using Regression Models with Count Outcomes Using R
ERIC Educational Resources Information Center
Beaujean, A. Alexander; Morgan, Grant B.
2016-01-01
Education researchers often study count variables, such as times a student reached a goal, discipline referrals, and absences. Most researchers that study these variables use typical regression methods (i.e., ordinary least-squares) either with or without transforming the count variables. In either case, using typical regression for count data can…
Sources and magnitude of sampling error in redd counts for bull trout
Jason B. Dunham; Bruce Rieman
2001-01-01
Monitoring of salmonid populations often involves annual redd counts, but the validity of this method has seldom been evaluated. We conducted redd counts of bull trout Salvelinus confluentus in two streams in northern Idaho to address four issues: (1) relationships between adult escapements and redd counts; (2) interobserver variability in redd...
CORNAS: coverage-dependent RNA-Seq analysis of gene expression data without biological replicates.
Low, Joel Z B; Khang, Tsung Fei; Tammi, Martti T
2017-12-28
In current statistical methods for calling differentially expressed genes in RNA-Seq experiments, the assumption is that an adjusted observed gene count represents an unknown true gene count. This adjustment usually consists of a normalization step to account for heterogeneous sample library sizes, and then the resulting normalized gene counts are used as input for parametric or non-parametric differential gene expression tests. A distribution of true gene counts, each with a different probability, can result in the same observed gene count. Importantly, sequencing coverage information is currently not explicitly incorporated into any of the statistical models used for RNA-Seq analysis. We developed a fast Bayesian method which uses the sequencing coverage information determined from the concentration of an RNA sample to estimate the posterior distribution of a true gene count. Our method has better or comparable performance compared to NOISeq and GFOLD, according to the results from simulations and experiments with real unreplicated data. We incorporated a previously unused sequencing coverage parameter into a procedure for differential gene expression analysis with RNA-Seq data. Our results suggest that our method can be used to overcome analytical bottlenecks in experiments with limited number of replicates and low sequencing coverage. The method is implemented in CORNAS (Coverage-dependent RNA-Seq), and is available at https://github.com/joel-lzb/CORNAS .
Unimanual SNARC Effect: Hand Matters.
Riello, Marianna; Rusconi, Elena
2011-01-01
A structural representation of the hand embedding information about the identity and relative position of fingers is necessary to counting routines. It may also support associations between numbers and allocentric spatial codes that predictably interact with other known numerical spatial representations, such as the mental number line (MNL). In this study, 48 Western participants whose typical counting routine proceeded from thumb-to-little on both hands performed magnitude and parity binary judgments. Response keys were pressed either with the right index and middle fingers or with the left index and middle fingers in separate blocks. 24 participants responded with either hands in prone posture (i.e., palm down) and 24 participants responded with either hands in supine (i.e., palm up) posture. When hands were in prone posture, the counting direction of the left hand conflicted with the direction of the left-right MNL, whereas the counting direction of the right hand was consistent with it. When hands were in supine posture, the opposite was true. If systematic associations existed between relative number magnitude and an allocentric spatial representation of the finger series within each hand, as predicted on the basis of counting habits, interactions would be expected between hand posture and a unimanual version of the spatial-numerical association of response codes (SNARC) effect. Data revealed that with hands in prone posture a unimanual SNARC effect was present for the right hand, and with hands in supine posture a unimanual SNARC effect was present for the left hand. We propose that a posture-invariant body structural representation of the finger series provides a relevant frame of reference, a within-hand directional vector, that is associated to simple number processing. Such frame of reference can significantly interact with stimulus-response correspondence effects, like the SNARC, that have been typically attributed to the mapping of numbers on a left-to-right mental line.
A gravimetric simplified method for nucleated marrow cell counting using an injection needle.
Saitoh, Toshiki; Fang, Liu; Matsumoto, Kiyoshi
2005-08-01
A simplified gravimetric marrow cell counting method for rats is proposed for a regular screening method. After fresh bone marrow was aspirated by an injection needle, the marrow cells were suspended in carbonate buffered saline. The nucleated marrow cell count (NMC) was measured by an automated multi-blood cell analyzer. When this gravimetric method was applied to rats, the NMC of the left and right femurs had essentially identical values due to careful handling. The NMC at 4 to 10 weeks of age in male and female Crj:CD(SD)IGS rats was 2.72 to 1.96 and 2.75 to 1.98 (x10(6) counts/mg), respectively. More useful information for evaluation could be obtained by using this gravimetric method in addition to myelogram examination. However, some difficulties with this method include low NMC due to blood contamination and variation of NMC due to handling. Therefore, the utility of this gravimetric method for screening will be clarified by the accumulation of the data on myelotoxicity studies with this method.
Protecting count queries in study design.
Vinterbo, Staal A; Sarwate, Anand D; Boxwala, Aziz A
2012-01-01
Today's clinical research institutions provide tools for researchers to query their data warehouses for counts of patients. To protect patient privacy, counts are perturbed before reporting; this compromises their utility for increased privacy. The goal of this study is to extend current query answer systems to guarantee a quantifiable level of privacy and allow users to tailor perturbations to maximize the usefulness according to their needs. A perturbation mechanism was designed in which users are given options with respect to scale and direction of the perturbation. The mechanism translates the true count, user preferences, and a privacy level within administrator-specified bounds into a probability distribution from which the perturbed count is drawn. Users can significantly impact the scale and direction of the count perturbation and can receive more accurate final cohort estimates. Strong and semantically meaningful differential privacy is guaranteed, providing for a unified privacy accounting system that can support role-based trust levels. This study provides an open source web-enabled tool to investigate visually and numerically the interaction between system parameters, including required privacy level and user preference settings. Quantifying privacy allows system administrators to provide users with a privacy budget and to monitor its expenditure, enabling users to control the inevitable loss of utility. While current measures of privacy are conservative, this system can take advantage of future advances in privacy measurement. The system provides new ways of trading off privacy and utility that are not provided in current study design systems.
LOSS OF BLOOD AT OPERATION—A Method for Continuous Measurement
Borden, Fred W.
1957-01-01
A method for continuous measurement of surgical blood loss has been devised and has been used clinically in some 400 cases. The method combines volumetric measure of the suction loss and gravimetric measure of the sponge loss. The volumetric device automatically deducts the volume of rinse water used and thus measures the amount of blood collected in a metering cylinder. The suction loss scale shows continuously the amount of blood in the metering cylinder. The gravimetric device requires counting sponges into the weighing pan, and turning a dial scale to deduct the initial weight of the sponges. The volume of blood in the sponges is then read directly on the dial scale. Use of the instrument, which is under the supervision of the anesthesiologist, adds about two minutes per hour to the time normally required for counting the sponges; and about three minutes per hour is required for tending the volumetric instrument. In clinical use, knowing constantly the amount of blood loss permits the starting of transfusion before serious deficit develops, and then maintaining the patient's blood volume at a predetermined optimum level. In some 400 cases the continuous measurement of the blood loss served as a reliable guide for carrying out the loss-replacement plan within close limits of accuracy. ImagesFigure 2.p97-a PMID:13446754
Kobayashi, Keisuke; Saeki, Yusuke; Kitazawa, Shinsuke; Kobayashi, Naohiro; Kikuchi, Shinji; Goto, Yukinobu; Sakai, Mitsuaki; Sato, Yukio
2017-11-01
It is important to accurately predict the patient's postoperative pulmonary function. The aim of this study was to compare the accuracy of predictions of the postoperative residual pulmonary function obtained with three-dimensional computed tomographic (3D-CT) volumetry with that of predictions obtained with the conventional segment-counting method. Fifty-three patients scheduled to undergo lung cancer resection, pulmonary function tests, and computed tomography were enrolled in this study. The postoperative residual pulmonary function was predicted based on the segment-counting and 3D-CT volumetry methods. The predicted postoperative values were compared with the results of postoperative pulmonary function tests. Regarding the linear correlation coefficients between the predicted postoperative values and the measured values, those obtained using the 3D-CT volumetry method tended to be higher than those acquired using the segment-counting method. In addition, the variations between the predicted and measured values were smaller with the 3D-CT volumetry method than with the segment-counting method. These results were more obvious in COPD patients than in non-COPD patients. Our findings suggested that the 3D-CT volumetry was able to predict the residual pulmonary function more accurately than the segment-counting method, especially in patients with COPD. This method might lead to the selection of appropriate candidates for surgery among patients with a marginal pulmonary function.
Automated Quantification of Arbitrary Arm-Segment Structure in Spiral Galaxies
NASA Astrophysics Data System (ADS)
Davis, Darren Robert
This thesis describes a system that, given approximately-centered images of spiral galaxies, produces quantitative descriptions of spiral galaxy structure without the need for per-image human input. This structure information consists of a list of spiral arm segments, each associated with a fitted logarithmic spiral arc and a pixel region. This list-of-arcs representation allows description of arbitrary spiral galaxy structure: the arms do not need to be symmetric, may have forks or bends, and, more generally, may be arranged in any manner with a consistent spiral-pattern center (non-merging galaxies have a sufficiently well-defined center). Such flexibility is important in order to accommodate the myriad structure variations observed in spiral galaxies. From the arcs produced from our method it is possible to calculate measures of spiral galaxy structure such as winding direction, winding tightness, arm counts, asymmetry, or other values of interest (including user-defined measures). In addition to providing information about the spiral arm "skeleton" of each galaxy, our method can enable analyses of brightness within individual spiral arms, since we provide the pixel regions associated with each spiral arm segment. For winding direction, arm tightness, and arm count, comparable information is available (to various extents) from previous efforts; to the extent that such information is available, we find strong correspondence with our output. We also characterize the changes to (and invariances in) our output as a function of modifications to important algorithm parameters. By enabling generation of extensive data about spiral galaxy structure from large-scale sky surveys, our method will enable new discoveries and tests regarding the nature of galaxies and the universe, and will facilitate subsequent work to automatically fit detailed brightness models of spiral galaxies.
Feldsine, Philip T; Leung, Stephanie C; Lienau, Andrew H; Mui, Linda A; Townsend, David E
2003-01-01
The relative efficacy of the SimPlate Total Plate Count-Color Indicator (TPC-CI) method (SimPlate 35 degrees C) was compared with the AOAC Official Method 966.23 (AOAC 35 degrees C) for enumeration of total aerobic microorganisms in foods. The SimPlate TPC-CI method, incubated at 30 degrees C (SimPlate 30 degrees C), was also compared with the International Organization for Standardization (ISO) 4833 method (ISO 30 degrees C). Six food types were analyzed: ground black pepper, flour, nut meats, frozen hamburger patties, frozen fruits, and fresh vegetables. All foods tested were naturally contaminated. Nineteen laboratories throughout North America and Europe participated in the study. Three method comparisons were conducted. In general, there was <0.3 mean log count difference in recovery among the SimPlate methods and their corresponding reference methods. Mean log counts between the 2 reference methods were also very similar. Repeatability (Sr) and reproducibility (SR) standard deviations were similar among the 3 method comparisons. The SimPlate method (35 degrees C) and the AOAC method were comparable for enumerating total aerobic microorganisms in foods. Similarly, the SimPlate method (30 degrees C) was comparable to the ISO method when samples were prepared and incubated according to the ISO method.
Automated cell counts on CSF samples: A multicenter performance evaluation of the GloCyte system.
Hod, E A; Brugnara, C; Pilichowska, M; Sandhaus, L M; Luu, H S; Forest, S K; Netterwald, J C; Reynafarje, G M; Kratz, A
2018-02-01
Automated cell counters have replaced manual enumeration of cells in blood and most body fluids. However, due to the unreliability of automated methods at very low cell counts, most laboratories continue to perform labor-intensive manual counts on many or all cerebrospinal fluid (CSF) samples. This multicenter clinical trial investigated if the GloCyte System (Advanced Instruments, Norwood, MA), a recently FDA-approved automated cell counter, which concentrates and enumerates red blood cells (RBCs) and total nucleated cells (TNCs), is sufficiently accurate and precise at very low cell counts to replace all manual CSF counts. The GloCyte System concentrates CSF and stains RBCs with fluorochrome-labeled antibodies and TNCs with nucleic acid dyes. RBCs and TNCs are then counted by digital image analysis. Residual adult and pediatric CSF samples obtained for clinical analysis at five different medical centers were used for the study. Cell counts were performed by the manual hemocytometer method and with the GloCyte System following the same protocol at all sites. The limits of the blank, detection, and quantitation, as well as precision and accuracy of the GloCyte, were determined. The GloCyte detected as few as 1 TNC/μL and 1 RBC/μL, and reliably counted as low as 3 TNCs/μL and 2 RBCs/μL. The total coefficient of variation was less than 20%. Comparison with cell counts obtained with a hemocytometer showed good correlation (>97%) between the GloCyte and the hemocytometer, including at very low cell counts. The GloCyte instrument is a precise, accurate, and stable system to obtain red cell and nucleated cell counts in CSF samples. It allows for the automated enumeration of even very low cell numbers, which is crucial for CSF analysis. These results suggest that GloCyte is an acceptable alternative to the manual method for all CSF samples, including those with normal cell counts. © 2017 John Wiley & Sons Ltd.
Dynamic time-correlated single-photon counting laser ranging
NASA Astrophysics Data System (ADS)
Peng, Huan; Wang, Yu-rong; Meng, Wen-dong; Yan, Pei-qin; Li, Zhao-hui; Li, Chen; Pan, Hai-feng; Wu, Guang
2018-03-01
We demonstrate a photon counting laser ranging experiment with a four-channel single-photon detector (SPD). The multi-channel SPD improve the counting rate more than 4×107 cps, which makes possible for the distance measurement performed even in daylight. However, the time-correlated single-photon counting (TCSPC) technique cannot distill the signal easily while the fast moving targets are submersed in the strong background. We propose a dynamic TCSPC method for fast moving targets measurement by varying coincidence window in real time. In the experiment, we prove that targets with velocity of 5 km/s can be detected according to the method, while the echo rate is 20% with the background counts of more than 1.2×107 cps.
Patrick, Thomas E.; Goodwin, T. L.; Collins, J. A.; Wyche, R. C.; Love, B. E.
1972-01-01
A comparison of two types of scalders was conducted to determine their effectiveness in reducing bacterial contamination of poultry carcasses. A conventional hot-water scalder and a prototype model of a steam scalder were tested under commercial conditions. Total plate counts from steam-scalded birds were significantly lower than the counts of water-scalded birds immediately after scalding and again after picking. No differences in the two methods could be found after chilling. Coliform counts from steam-scalded birds were significantly lower than the counts from water-scalded birds immediately after scalding. No significant differences in coliform counts were detected when the two scald methods were compared after defeathering and chilling. PMID:4553146
NASA Astrophysics Data System (ADS)
Lim, Hongki; Dewaraja, Yuni K.; Fessler, Jeffrey A.
2018-02-01
Most existing PET image reconstruction methods impose a nonnegativity constraint in the image domain that is natural physically, but can lead to biased reconstructions. This bias is particularly problematic for Y-90 PET because of the low probability positron production and high random coincidence fraction. This paper investigates a new PET reconstruction formulation that enforces nonnegativity of the projections instead of the voxel values. This formulation allows some negative voxel values, thereby potentially reducing bias. Unlike the previously reported NEG-ML approach that modifies the Poisson log-likelihood to allow negative values, the new formulation retains the classical Poisson statistical model. To relax the non-negativity constraint embedded in the standard methods for PET reconstruction, we used an alternating direction method of multipliers (ADMM). Because choice of ADMM parameters can greatly influence convergence rate, we applied an automatic parameter selection method to improve the convergence speed. We investigated the methods using lung to liver slices of XCAT phantom. We simulated low true coincidence count-rates with high random fractions corresponding to the typical values from patient imaging in Y-90 microsphere radioembolization. We compared our new methods with standard reconstruction algorithms and NEG-ML and a regularized version thereof. Both our new method and NEG-ML allow more accurate quantification in all volumes of interest while yielding lower noise than the standard method. The performance of NEG-ML can degrade when its user-defined parameter is tuned poorly, while the proposed algorithm is robust to any count level without requiring parameter tuning.
Liu, Zhenqiu; Hsiao, William; Cantarel, Brandi L; Drábek, Elliott Franco; Fraser-Liggett, Claire
2011-12-01
Direct sequencing of microbes in human ecosystems (the human microbiome) has complemented single genome cultivation and sequencing to understand and explore the impact of commensal microbes on human health. As sequencing technologies improve and costs decline, the sophistication of data has outgrown available computational methods. While several existing machine learning methods have been adapted for analyzing microbiome data recently, there is not yet an efficient and dedicated algorithm available for multiclass classification of human microbiota. By combining instance-based and model-based learning, we propose a novel sparse distance-based learning method for simultaneous class prediction and feature (variable or taxa, which is used interchangeably) selection from multiple treatment populations on the basis of 16S rRNA sequence count data. Our proposed method simultaneously minimizes the intraclass distance and maximizes the interclass distance with many fewer estimated parameters than other methods. It is very efficient for problems with small sample sizes and unbalanced classes, which are common in metagenomic studies. We implemented this method in a MATLAB toolbox called MetaDistance. We also propose several approaches for data normalization and variance stabilization transformation in MetaDistance. We validate this method on several real and simulated 16S rRNA datasets to show that it outperforms existing methods for classifying metagenomic data. This article is the first to address simultaneous multifeature selection and class prediction with metagenomic count data. The MATLAB toolbox is freely available online at http://metadistance.igs.umaryland.edu/. zliu@umm.edu Supplementary data are available at Bioinformatics online.
Njenga, S M; Wamae, C N
2001-10-01
An immunochromatographic card test (ICT) that uses fingerprick whole blood instead of serum for diagnosis of bancroftian filariasis has recently been developed. The card test was validated in the field in Kenya by comparing its sensitivity to the combined sensitivity of Knott's concentration and counting chamber methods. A total of 102 (14.6%) and 117 (16.7%) persons was found to be microfilaremic by Knott's concentration and counting chamber methods, respectively. The geometric mean intensities (GMI) were 74.6 microfilariae (mf)/ml and 256.5 mf/ml by Knott's concentration and counting chamber methods, respectively. All infected individuals detected by both Knott's concentration and counting chamber methods were also antigen positive by the ICT filariasis card test (100% sensitivity). Further, of 97 parasitologically amicrofilaremic persons, 24 (24.7%) were antigen positive by the ICT. The overall prevalence of antigenemia was 37.3%. Of 100 nonendemic area control persons, none was found to be filarial antigen positive (100% specificity). The results show that the new version of the ICT filariasis card test is a simple, sensitive, specific, and rapid test that is convenient in field settings.
Skowron, Gail; Spritzler, John G.; Weidler, Jodi; Robbins, Gregory K.; Johnson, Victoria A.; Chan, Ellen S.; Asmuth, David M.; Gandhi, Rajesh T.; Lie, Yolanda; Bates, Michael; Pollard, Richard B.
2012-01-01
Objectives To evaluate the association between baseline (BL) replication capacity (RC) [RCBL] and immunologic/virologic parameters (at BL and after 48 weeks on therapy) in HIV-1 infected subjects initiating antiretroviral therapy. Methods RCBL was determined using a modified Monogram PhenoSense HIV drug susceptibility assay on plasma HIV-1 from 321 treatment-naïve subjects from ACTG384. Univariate and multivariable analyses were performed to determine the association of RCBL with BL and on-therapy virologic and immunologic outcomes. Results Higher RCBL was associated with lower baseline CD4 (CD4BL) (r=−0.23, p<0.0001), higher baseline HIV-1 (RNABL) (r=0.25, p<0.0001), higher CD4BL activation percent (r=0.23, p<0.0001) and lower CD4BL memory count (r=−0.21, p=0.0002). In a multivariable model, week 48 CD4 increase (ΔCD448) was associated with lower CD4BL memory count and higher CD4BL naive percent (p=0.004, p=0.015, respectively). The interaction between CD4BL and RCBL was significant (p=0.018), with a positive association between RCBL and ΔCD448 in subjects with higher CD4BL, and a negative association at lower absCD4BL. Conclusions At baseline, higher RC was significantly associated with higher HIV-1 RNA, higher CD4 cell activation, lower CD4 cell count, and lower CD4 memory cell count. These factors may interact, directly or indirectly, to modify the extent to which CD4 recovery occurs in patients starting antiretroviral therapy at different baseline CD4 counts. PMID:19194319
Inspection Methods in Programming.
1981-06-01
Counting is a a specialization of Iterative-generation in which the generating function is Oneplus ) Waters’ second category of plan building method...is Oneplus and the initial input is 1. 0 I 180 CHAPTER NINE -ta a acio f igr9-.IeaieGnrtoPln 7 -7 STEADY STATE PLANS 181 TemporalPlan counting...specializalion iterative-generation roles .action(afu nction) ,tail(counting) conslraints .action.op = oneplus A .action.input = 1 The lItcrative-application
DOE Office of Scientific and Technical Information (OSTI.GOV)
Vedantham, Srinivasan; Shrestha, Suman; Karellas, Andrew, E-mail: andrew.karellas@umassmed.edu
Purpose: High-resolution, photon-counting, energy-resolved detector with fast-framing capability can facilitate simultaneous acquisition of precontrast and postcontrast images for subtraction angiography without pixel registration artifacts and can facilitate high-resolution real-time imaging during image-guided interventions. Hence, this study was conducted to determine the spatial resolution characteristics of a hexagonal pixel array photon-counting cadmium telluride (CdTe) detector. Methods: A 650 μm thick CdTe Schottky photon-counting detector capable of concurrently acquiring up to two energy-windowed images was operated in a single energy-window mode to include photons of 10 keV or higher. The detector had hexagonal pixels with apothem of 30 μm resulting in pixelmore » pitch of 60 and 51.96 μm along the two orthogonal directions. The detector was characterized at IEC-RQA5 spectral conditions. Linear response of the detector was determined over the air kerma rate relevant to image-guided interventional procedures ranging from 1.3 nGy/frame to 91.4 μGy/frame. Presampled modulation transfer was determined using a tungsten edge test device. The edge-spread function and the finely sampled line spread function accounted for hexagonal sampling, from which the presampled modulation transfer function (MTF) was determined. Since detectors with hexagonal pixels require resampling to square pixels for distortion-free display, the optimal square pixel size was determined by minimizing the root-mean-squared-error of the aperture functions for the square and hexagonal pixels up to the Nyquist limit. Results: At Nyquist frequencies of 8.33 and 9.62 cycles/mm along the apothem and orthogonal to the apothem directions, the modulation factors were 0.397 and 0.228, respectively. For the corresponding axis, the limiting resolution defined as 10% MTF occurred at 13.3 and 12 cycles/mm, respectively. Evaluation of the aperture functions yielded an optimal square pixel size of 54 μm. After resampling to 54 μm square pixels using trilinear interpolation, the presampled MTF at Nyquist frequency of 9.26 cycles/mm was 0.29 and 0.24 along the orthogonal directions and the limiting resolution (10% MTF) occurred at approximately 12 cycles/mm. Visual analysis of a bar pattern image showed the ability to resolve close to 12 line-pairs/mm and qualitative evaluation of a neurovascular nitinol-stent showed the ability to visualize its struts at clinically relevant conditions. Conclusions: Hexagonal pixel array photon-counting CdTe detector provides high spatial resolution in single-photon counting mode. After resampling to optimal square pixel size for distortion-free display, the spatial resolution is preserved. The dual-energy capabilities of the detector could allow for artifact-free subtraction angiography and basis material decomposition. The proposed high-resolution photon-counting detector with energy-resolving capability can be of importance for several image-guided interventional procedures as well as for pediatric applications.« less
Variations in pollen counts largely explained by climate and weather
NASA Astrophysics Data System (ADS)
Jung, Stephan; Damialis, Athanasios; Estrella, Nicole; Jochner, Susanne; Menzel, Annette
2017-04-01
The interaction between climate and vegetation is well studied within phenology. Climatic / weather conditions affect e.g. flowering date, length of vegetation period, start and end of the season and the plant growth. Besides phenological stages also pollen counts can be used to investigate the interaction between climate and vegetation. Pollen emission and distribution is directly influenced by temperature, wind speed, wind direction and humidity/precipitation. The objective of this project is to study daily/sub daily variations in pollen counts of woody and herbaceous plant species along an altitudinal gradient with different climatic conditions during the vegetation period. Measurements of pollen were carried out with three volumetric pollen traps installed at the altitudes 450 m a.s.l (Freising), 700 m a.s.l (Garmisch-Partenkirchen), and 2700 m a.s.l (Schneefernerhaus near Zugspitze) representing gradient from north of Munich towards the highest mountain of Germany. Airborne pollen concentrations were recorded during the years 2014-2015. The altitudinal range of these three stations accompanied by different microclimates ("space for time approach") can be used as proxy for climate change and to assess its impact on pollen counts and thus allergenic risk for human health. For example the pollen season is shortened and pollen amount is reduced at higher sites. For detailed investigations pollen of the species Plantago, Quercus, Poaceae, Cupressaceae, Cyperacea, Betula and Platanus were chosen, because those are found in appropriate quantities. In general, pollen captured in the pollen traps to a certain extent has its origin from the immediate surrounding. Thus, it mirrors local species distribution. But furthermore the distance of pollen transport is also based on (micro-) climatic conditions, land cover and topography. The pollen trap shortly below the summit of Zugspitze (Schneefernerhaus) has an alpine environment without vegetation nearby. Therefore, this trap can be used to detect short-, middle- and long-range pollen transport. The pollen trap in Garmisch-Partenkirchen is located in the valley below Zugspitze making these two stations suitable for a direct comparison. First results show that the total amount of pollen at Schneefernerhaus for Plantago, Quercus, Poaceae, Cupressaceae, Cyperaceae and Betula is only about 20% in comparison to Garmisch. Furthermore there are daily differences in the pollen counts in yearly sum between morning (24:00 -12:00) and afternoon (12:00- 24:00). This phenomenon might be caused by diurnal climatic variations in the boundary layer as well as local mountain wind systems (changing wind direction from morning to afternoon time). Additionally pollen counts were linked to weather data recorded by the German Meteorological Service and local climate stations. Results indicate that the duration of precipitation events is a major factor of influence concerning the counted pollen. With increasing duration of a rain event pollen counts are decreasing.
Modern Measurements of Uranium Decay Rates
NASA Astrophysics Data System (ADS)
Parsons-Moss, T.; Faye, S. A.; Williams, R. W.; Wang, T. F.; Renne, P. R.; Mundil, R.; Harrison, M.; Bandong, B. B.; Moody, K.; Knight, K. B.
2015-12-01
It has been widely recognized that accurate and precise decay constants (λ) are critical to geochronology as highlighted by the EARTHTIME initiative, particularly the calibration benchmarks λ235U and λ238U. [1] Alpha counting experiments in 1971[2] measured λ235U and λ238U with ~0.1% precision, but have never been independently validated. We are embarking on new direct measurements of λ235U, λ238U, λ234Th, and λ234U using independent approaches for each nuclide. For the measurement of λ235U, highly enriched 235U samples will be chemically purified and analyzed for U concentration and isotopic composition by multi-collector inductively coupled plasma mass spectrometry (MC-ICP-MS). Thin films will be electrodeposited from these solutions and the α activity will be measured in an α-γ coincidence counting apparatus, which allows reduced uncertainty in counting efficiency while achieving adequate counting statistics. For λ238U measurement we will measure ingrowth of 234Th in chemically purified, isotopically enriched 238U solutions, by quantitatively separating the Th and allowing complete decay to 234U. All of the measurements will be done using MC-ICP-MS aiming at 0.05% precision. This approach is expected to result in values of λ238U with less than 0.1% uncertainty, if combined with improved λ234Th measements. These will be achieved using direct decay measurements with an E-ΔE charged particle telescope in coincidence with a gamma detector. This system allows measurement of 234Th β-decay and simultaneous detection and identification of α particles emitted by the 234U daughter, thus observing λ234U at the same time. The high-precision λ234U obtained by the direct activity measurements can independently verify the commonly used values obtained by indirect methods.[3] An overarching goal of the project is to ensure the quality of results including metrological traceability in order to facilitate implementation across diverse disciplines. [1] T.M. Harrison et al., (2015) It's About Time:Opportunities and Challenges for U.S. Geological Survey. Institute of Geophysics and Planetary Physics Publication 6539, University of California, Los Angeles [2] A. H. Jaffey et al., Physical Review C, 4, 5, (1971), 1889-1906 [3] H. Cheng et al., Chemical Geology, 169, (2000), 17-33
The effect of blood cell count on coronary flow in patients with coronary slow flow phenomenon
Soylu, Korhan; Gulel, Okan; Yucel, Huriye; Yuksel, Serkan; Aksan, Gokhan; Soylu, Ayşegül İdil; Demircan, Sabri; Yılmaz, Özcan; Sahin, Mahmut
2014-01-01
Background and Objective: The coronary slow flow phenomenon (CSFP) is a coronary artery disease with a benign course, but its pathological mechanisms are not yet fully understood.The purpose of this controlled study was to investigate the cellular content of blood in patients diagnosed with CSFP and the relationship of this with coronary flow rates. Methods: Selective coronary angiographies of 3368 patients were analyzed to assess Thrombolysis in Myocardial Infarction (TIMI) frame count (TFC) values. Seventy eight of them had CSFP, and their demographic and laboratory findings were compared with 61 patients with normal coronary flow. Results: Patients’ demographic characteristics were similar in both groups. Mean corrected TFC (cTFC) values were significantly elevated in CSFP patients (p<0.001). Furthermore, hematocrit and hemoglobin values, and eosinophil and basophil counts of the CSFP patients were significantly elevated compared to the values obtained in the control group (p=0.005, p=0.047, p=0.001 and p=0.002, respectively). The increase observed in hematocrit and eosinophil levels showed significant correlations with increased TFC values (r=0.288 and r=0.217, respectively). Conclusion: Significant changes have been observed in the cellular composition of blood in patients diagnosed with CSFP as compared to the patients with normal coronary blood flow. The increases in hematocrit levels and in the eosinophil and basophil counts may have direct or indirect effects on the rate of coronary blood flow. PMID:25225502
Circulating endothelial cells as marker of endothelial damage in male hypogonadism.
Milardi, Domenico; Grande, Giuseppe; Giampietro, Antonella; Vendittelli, Francesca; Palumbo, Sara; Tartaglione, Linda; Marana, Riccardo; Pontecorvi, Alfredo; de Marinis, Laura; Zuppi, Cecilia; Capoluongo, Ettore
2012-01-01
Testosterone deficiency has become a frequently diagnosed condition in today's society affected by epidemic obesity, and is associated with cardiovascular risk. Recent studies have established the importance of altered vascular endothelium function in cardiovascular disease. The damage to the endothelium might also cause endothelial cell detachment, resulting in increased numbers of circulating endothelial cells (CEC) within the bloodstream. To evaluate whether hypogonadism could modify CEC count in peripheral bloodstream, we investigated peripheral blood CEC count using the CellSearch System, a semiautomatic method to accurately and reliably enumerate CECs, which are sorted based on a CD146(+), CD105(+), DAPI(+), CD45(-) phenotype, in a population of 20 patients with hypogonadism. The control group comprised 10 age- and sex-matched healthy participants. CEC count per milliliter was significantly increased in patients with hypogonadism vs the control group. In the group with hypogonadism, an inverse exponential correlation was present between testosterone levels and CEC count per milliliter. A direct linear correlation was present between waist circumference and CECs and between body mass index and CECs. The regression analysis showed that testosterone was the significant independent determinant of CECs. Our results underline that male hypogonadism is associated with endothelial dysfunction. The correlation between CEC and waist circumference underlines that visceral obesity may be synergically implicated in this regulation. Future studies are required to unveil the mechanisms involved in the pathogenesis of testosterone-induced endothelial disfunction, which may provide novel therapeutic targets to be incorporated in the management of hypogonadism.
Zugaza, J L; Casabiell, X A; Bokser, L; Eiras, A; Beiras, A; Casanueva, F F
1995-07-01
We have previously demonstrated that pretreatment of several cell lines with cis-unsaturated fatty acids, like oleic acid, blocks epidermal growth factor (EGF)-induced early ionic signals, and in particular the [Ca2+]i rise. In the present work we show that this blockade does not alter EGF-stimulated cellular proliferation evaluated by direct cell counting, but induces a powerful enhancement in the pulsed thymidine incorporation assay. The lack of effect of oleic acid on EGF-stimulated cellular proliferation was confirmed by repeated cell counts, cumulative thymidine incorporation, and protein synthesis, but a clear synergistic effect between oleic acid and EGF was again obtained by means of time course experiments with pulsed thymidine. Combined flow cytometry analysis and cell counts at earlier times in EGF-stimulated cells showed that oleic acids accelerates the entrance of cells into the replicative cycle leading to an earlier cell division. Afterward, these oleic acid-pretreated cells became delayed by an unknown compensatory mechanism in such a way that at 48 h post-EGF, the cell count in control and oleic acid-pretreated cells was equal. In conclusion (a) oleic acid accelerates or enhances the EGF mitogenic action and (b) in the long term cells compensate the initial perturbation with respect to untreated cells. As a side observation, the widely employed pulsed thymidine incorporation method as a measure of cell division could be extremely misleading unless experimental conditions are well controlled.
Dittami, Gregory M; Sethi, Manju; Rabbitt, Richard D; Ayliffe, H Edward
2012-06-21
Particle and cell counting is used for a variety of applications including routine cell culture, hematological analysis, and industrial controls(1-5). A critical breakthrough in cell/particle counting technologies was the development of the Coulter technique by Wallace Coulter over 50 years ago. The technique involves the application of an electric field across a micron-sized aperture and hydrodynamically focusing single particles through the aperture. The resulting occlusion of the aperture by the particles yields a measurable change in electric impedance that can be directly and precisely correlated to cell size/volume. The recognition of the approach as the benchmark in cell/particle counting stems from the extraordinary precision and accuracy of its particle sizing and counts, particularly as compared to manual and imaging based technologies (accuracies on the order of 98% for Coulter counters versus 75-80% for manual and vision-based systems). This can be attributed to the fact that, unlike imaging-based approaches to cell counting, the Coulter Technique makes a true three-dimensional (3-D) measurement of cells/particles which dramatically reduces count interference from debris and clustering by calculating precise volumetric information about the cells/particles. Overall this provides a means for enumerating and sizing cells in a more accurate, less tedious, less time-consuming, and less subjective means than other counting techniques(6). Despite the prominence of the Coulter technique in cell counting, its widespread use in routine biological studies has been prohibitive due to the cost and size of traditional instruments. Although a less expensive Coulter-based instrument has been produced, it has limitations as compared to its more expensive counterparts in the correction for "coincidence events" in which two or more cells pass through the aperture and are measured simultaneously. Another limitation with existing Coulter technologies is the lack of metrics on the overall health of cell samples. Consequently, additional techniques must often be used in conjunction with Coulter counting to assess cell viability. This extends experimental setup time and cost since the traditional methods of viability assessment require cell staining and/or use of expensive and cumbersome equipment such as a flow cytometer. The Moxi Z mini automated cell counter, described here, is an ultra-small benchtop instrument that combines the accuracy of the Coulter Principle with a thin-film sensor technology to enable precise sizing and counting of particles ranging from 3-25 microns, depending on the cell counting cassette used. The M type cassette can be used to count particles from with average diameters of 4 - 25 microns (dynamic range 2 - 34 microns), and the Type S cassette can be used to count particles with and average diameter of 3 - 20 microns (dynamic range 2 - 26 microns). Since the system uses a volumetric measurement method, the 4-25 microns corresponds to a cell volume range of 34 - 8,180 fL and the 3 - 20 microns corresponds to a cell volume range of 14 - 4200 fL, which is relevant when non-spherical particles are being measured. To perform mammalian cell counts using the Moxi Z, the cells to be counted are first diluted with ORFLO or similar diluent. A cell counting cassette is inserted into the instrument, and the sample is loaded into the port of the cassette. Thousands of cells are pulled, single-file through a "Cell Sensing Zone" (CSZ) in the thin-film membrane over 8-15 seconds. Following the run, the instrument uses proprietary curve-fitting in conjunction with a proprietary software algorithm to provide coincidence event correction along with an assessment of overall culture health by determining the ratio of the number of cells in the population of interest to the total number of particles. The total particle counts include shrunken and broken down dead cells, as well as other debris and contaminants. The results are presented in histogram format with an automatic curve fit, with gates that can be adjusted manually as needed. Ultimately, the Moxi Z enables counting with a precision and accuracy comparable to a Coulter Z2, the current gold standard, while providing additional culture health information. Furthermore it achieves these results in less time, with a smaller footprint, with significantly easier operation and maintenance, and at a fraction of the cost of comparable technologies.
NASA Astrophysics Data System (ADS)
Smith, Zachary J.; Gao, Tingjuan; Lin, Tzu-Yin; Carrade-Holt, Danielle; Lane, Stephen M.; Matthews, Dennis L.; Dwyre, Denis M.; Wachsmann-Hogiu, Sebastian
2016-03-01
Cell counting in human body fluids such as blood, urine, and CSF is a critical step in the diagnostic process for many diseases. Current automated methods for cell counting are based on flow cytometry systems. However, these automated methods are bulky, costly, require significant user expertise, and are not well suited to counting cells in fluids other than blood. Therefore, their use is limited to large central laboratories that process enough volume of blood to recoup the significant capital investment these instruments require. We present in this talk a combination of a (1) low-cost microscope system, (2) simple sample preparation method, and (3) fully automated analysis designed for providing cell counts in blood and body fluids. We show results on both humans and companion and farm animals, showing that accurate red cell, white cell, and platelet counts, as well as hemoglobin concentration, can be accurately obtained in blood, as well as a 3-part white cell differential in human samples. We can also accurately count red and white cells in body fluids with a limit of detection ~3 orders of magnitude smaller than current automated instruments. This method uses less than 1 microliter of blood, and less than 5 microliters of body fluids to make its measurements, making it highly compatible with finger-stick style collections, as well as appropriate for small animals such as laboratory mice where larger volume blood collections are dangerous to the animal's health.
Zago, Laure; Badets, Arnaud
2016-01-01
The goal of the present study was to test whether there is a relationship between manual preference and hand-digit mapping in 369 French adults with similar numbers of right- and left-handers. Manual laterality was evaluated with the finger tapping test to evaluate hand motor asymmetry, and the Edinburgh handedness inventory was used to assess manual preference strength (MPS) and direction. Participants were asked to spontaneously "count on their fingers from 1 to 10" without indications concerning the hand(s) to be used. The results indicated that both MPS and hand motor asymmetry affect the hand-starting preference for counting. Left-handers with a strong left-hand preference (sLH) or left-hand motor asymmetry largely started to count with their left hand (left-starter), while right-handers with a strong right-hand preference (sRH) or right-hand motor asymmetry largely started to count with their right hand (right-starter). Notably, individuals with weak MPS did not show a hand-starting preference. These findings demonstrated that manual laterality contributes to finger counting directionality. Lastly, the results showed a higher proportion of sLH left-starter individuals compared with sRH right-starters, indicating an asymmetric bias of MPS on hand-starting preference. We hypothesize that the higher proportion of sLH left-starters could be explained by the congruence between left-to-right hand-digit mapping and left-to-right mental number line representation that has been largely reported in the literature. Taken together, these results indicate that finger-counting habits integrate biological and cultural information. © The Author(s) 2015.
Xing, Jian; Burkom, Howard; Tokars, Jerome
2011-12-01
Automated surveillance systems require statistical methods to recognize increases in visit counts that might indicate an outbreak. In prior work we presented methods to enhance the sensitivity of C2, a commonly used time series method. In this study, we compared the enhanced C2 method with five regression models. We used emergency department chief complaint data from US CDC BioSense surveillance system, aggregated by city (total of 206 hospitals, 16 cities) during 5/2008-4/2009. Data for six syndromes (asthma, gastrointestinal, nausea and vomiting, rash, respiratory, and influenza-like illness) was used and was stratified by mean count (1-19, 20-49, ≥50 per day) into 14 syndrome-count categories. We compared the sensitivity for detecting single-day artificially-added increases in syndrome counts. Four modifications of the C2 time series method, and five regression models (two linear and three Poisson), were tested. A constant alert rate of 1% was used for all methods. Among the regression models tested, we found that a Poisson model controlling for the logarithm of total visits (i.e., visits both meeting and not meeting a syndrome definition), day of week, and 14-day time period was best. Among 14 syndrome-count categories, time series and regression methods produced approximately the same sensitivity (<5% difference) in 6; in six categories, the regression method had higher sensitivity (range 6-14% improvement), and in two categories the time series method had higher sensitivity. When automated data are aggregated to the city level, a Poisson regression model that controls for total visits produces the best overall sensitivity for detecting artificially added visit counts. This improvement was achieved without increasing the alert rate, which was held constant at 1% for all methods. These findings will improve our ability to detect outbreaks in automated surveillance system data. Published by Elsevier Inc.
Stratospheric CCN sampling program
NASA Technical Reports Server (NTRS)
Rogers, C. F.
1981-01-01
When Mt. St. Helens produced several major eruptions in the late spring of 1980, there was a strong interest in the characterization of the cloud condensation nuclei (CCN) activity of the material that was injected into the troposphere and stratosphere. The scientific value of CCN measurements is two fold: CCN counts may be directly applied to calculations of the interaction of the aerosol (enlargement) at atmospherically-realistic relative humidities or supersaturations; and if the chemical constituency of the aerosol can be assumed, the number-versus-critical supersaturation spectrum may be converted into a dry aerosol size spectrum covering a size region not readily measured by other methods. The sampling method is described along with the instrumentation used in the experiments.
Comparative analysis of quantitative methodologies for Vibrionaceae biofilms.
Chavez-Dozal, Alba A; Nourabadi, Neda; Erken, Martina; McDougald, Diane; Nishiguchi, Michele K
2016-11-01
Multiple symbiotic and free-living Vibrio spp. grow as a form of microbial community known as a biofilm. In the laboratory, methods to quantify Vibrio biofilm mass include crystal violet staining, direct colony-forming unit (CFU) counting, dry biofilm cell mass measurement, and observation of development of wrinkled colonies. Another approach for bacterial biofilms also involves the use of tetrazolium (XTT) assays (used widely in studies of fungi) that are an appropriate measure of metabolic activity and vitality of cells within the biofilm matrix. This study systematically tested five techniques, among which the XTT assay and wrinkled colony measurement provided the most reproducible, accurate, and efficient methods for the quantitative estimation of Vibrionaceae biofilms.
Bekana, Teshome; Mekonnen, Zeleke; Zeynudin, Ahmed; Ayana, Mio; Getachew, Mestawet; Vercruysse, Jozef; Levecke, Bruno
2015-10-01
There is a paucity of studies that compare efficacy of drugs obtained by different diagnostic methods. We compared the efficacy of a single oral dose albendazole (400 mg), measured as egg reduction rate, against soil-transmitted helminth infections in 210 school children (Jimma Town, Ethiopia) using both Kato-Katz thick smear and McMaster egg counting method. Our results indicate that differences in sensitivity and faecal egg counts did not imply a significant difference in egg reduction rate estimates. The choice of a diagnostic method to assess drug efficacy should not be based on sensitivity and faecal egg counts only. © The Author 2015. Published by Oxford University Press on behalf of Royal Society of Tropical Medicine and Hygiene. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com.
Winter, F H; York, G K; el-Nakhal, H
1971-07-01
A rapid method for estimating the extent of microbial contamination on food and on food processing equipment is described. Microbial cells are rinsed from food or swab samples with sterile diluent and concentrated on the surface of membrane filters. The filters are incubated on a suitable bacteriological medium for 4 hr at 30 C, heated at 105 C for 5 min, and stained. The membranes are then dried at 60 C for 15 min, rendered transparent with immersion oil, and examined microscopically. Data obtained by the rapid method were compared with counts of the same samples determined by the standard plate count method. Over 60 comparisons resulted in a correlation coefficient of 0.906. Because the rapid technique can provide reliable microbiological count information in extremely short times, it can be a most useful tool in the routine evaluation of microbial contamination of food processing facilities and for some foods.
2015-07-17
This figure shows how the Alice instrument count rate changed over time during the sunset and sunrise observations. The count rate is largest when the line of sight to the sun is outside of the atmosphere at the start and end times. Molecular nitrogen (N2) starts absorbing sunlight in the upper reaches of Pluto's atmosphere, decreasing as the spacecraft approaches the planet's shadow. As the occultation progresses, atmospheric methane and hydrocarbons can also absorb the sunlight and further decrease the count rate. When the spacecraft is totally in Pluto's shadow the count rate goes to zero. As the spacecraft emerges from Pluto's shadow into sunrise, the process is reversed. By plotting the observed count rate in the reverse time direction, it is seen that the atmospheres on opposite sides of Pluto are nearly identical. http://photojournal.jpl.nasa.gov/catalog/PIA19716
Establishment of HPC(R2A) for regrowth control in non-chlorinated distribution systems.
Uhl, Wolfgang; Schaule, Gabriela
2004-05-01
Drinking water distributed without disinfection and without regrowth problems for many years may show bacterial regrowth when the residence time and/or temperature in the distribution system increases or when substrate and/or bacterial concentration in the treated water increases. An example of a regrowth event in a major German city is discussed. Regrowth of HPC bacteria occurred unexpectedly at the end of a very hot summer. No pathogenic or potentially pathogenic bacteria were identified. Increased residence times in the distribution system and temperatures up to 25 degrees C were identified as most probable causes and the regrowth event was successfully overcome by changing flow regimes and decreasing residence times. Standard plate counts of HPC bacteria using the spread plate technique on nutrient rich agar according to German Drinking Water Regulations (GDWR) had proven to be a very good indicator of hygienically safe drinking water and to demonstrate the effectiveness of water treatment. However, the method proved insensitive for early regrowth detection. Regrowth experiments in the lab and sampling of the distribution system during two summers showed that spread plate counts on nutrient-poor R2A agar after 7-day incubation yielded 100 to 200 times higher counts. Counts on R2A after 3-day incubation were three times less than after 7 days. As the precision of plate count methods is very poor for counts less than 10 cfu/plate, a method yielding higher counts is better suited to detect upcoming regrowth than a method yielding low counts. It is shown that for the identification of regrowth events HPC(R2A) gives a further margin of about 2 weeks for reaction before HPC(GDWR). Copyright 2003 Elsevier B.V.
Software electron counting for low-dose scanning transmission electron microscopy.
Mittelberger, Andreas; Kramberger, Christian; Meyer, Jannik C
2018-05-01
The performance of the detector is of key importance for low-dose imaging in transmission electron microscopy, and counting every single electron can be considered as the ultimate goal. In scanning transmission electron microscopy, low-dose imaging can be realized by very fast scanning, however, this also introduces artifacts and a loss of resolution in the scan direction. We have developed a software approach to correct for artifacts introduced by fast scans, making use of a scintillator and photomultiplier response that extends over several pixels. The parameters for this correction can be directly extracted from the raw image. Finally, the images can be converted into electron counts. This approach enables low-dose imaging in the scanning transmission electron microscope via high scan speeds while retaining the image quality of artifact-free slower scans. Copyright © 2018 The Authors. Published by Elsevier B.V. All rights reserved.
Gonzalez-Martin, Cristina; Teigell-Perez, Nuria; Lyles, Mark; Valladares, Basilio; Griffin, Dale W.
2013-01-01
Topsoil from arid regions is the main source of dust clouds that move through the earth's atmosphere, and microbial communities within these soils can survive long-range dispersion. Microbial abundance and chemical composition were analyzed in topsoil from various desert regions. Statistical analyses showed that microbial direct counts were strongly positively correlated with calcium concentrations and negatively correlated with silicon concentrations. While variance between deserts was expected, it was interesting to note differences between sample sites within a given desert region, illustrating the 'patchy' nature of microbial communities in desert environments.
When Practice Doesn't Lead to Retrieval: An Analysis of Children's Errors with Simple Addition
ERIC Educational Resources Information Center
de Villiers, Celéste; Hopkins, Sarah
2013-01-01
Counting strategies initially used by young children to perform simple addition are often replaced by more efficient counting strategies, decomposition strategies and rule-based strategies until most answers are encoded in memory and can be directly retrieved. Practice is thought to be the key to developing fluent retrieval of addition facts. This…
A rapid method for quantification of 242Pu in urine using extraction chromatography and ICP-MS
Gallardo, Athena Marie; Than, Chit; Wong, Carolyn; ...
2017-01-01
Occupational exposure to plutonium is generally monitored through analysis of urine samples. Typically, plutonium is separated from the sample and other actinides, and the concentration is determined using alpha spectroscopy. Current methods for separations and analysis are lengthy and require long count times. A new method for monitoring occupational exposure levels of plutonium has been developed, which requires fewer steps and overall less time than the alpha spectroscopy method. In this method, the urine is acidified, and a 239Pu internal standard is added. The urine is digested in a microwave oven, and plutonium is separated using an Eichrom TRU Resinmore » column. The plutonium is eluted, and the eluant is injected directly into the Inductively Coupled Plasma–Mass Spectrometer (ICP-MS). Compared to a direct “dilute and shoot” method, a 30-fold improvement in sensitivity is achieved. This method was validated by analyzing several batches of spiked samples. Based on these analyses, a combined standard uncertainty plot, which relates uncertainty to concentration, was produced. As a result, the MDA 95 was calculated to be 7.0 × 10 –7 μg L –1, and the Lc95 was calculated to be 3.5 × 10 –7 μg L –1 for this method.« less
Conversion from Engineering Units to Telemetry Counts on Dryden Flight Simulators
NASA Technical Reports Server (NTRS)
Fantini, Jay A.
1998-01-01
Dryden real-time flight simulators encompass the simulation of pulse code modulation (PCM) telemetry signals. This paper presents a new method whereby the calibration polynomial (from first to sixth order), representing the conversion from counts to engineering units (EU), is numerically inverted in real time. The result is less than one-count error for valid EU inputs. The Newton-Raphson method is used to numerically invert the polynomial. A reverse linear interpolation between the EU limits is used to obtain an initial value for the desired telemetry count. The method presented here is not new. What is new is how classical numerical techniques are optimized to take advantage of modem computer power to perform the desired calculations in real time. This technique makes the method simple to understand and implement. There are no interpolation tables to store in memory as in traditional methods. The NASA F-15 simulation converts and transmits over 1000 parameters at 80 times/sec. This paper presents algorithm development, FORTRAN code, and performance results.
Angel, J.C.; Nelson, D.O.; Panno, S.V.
2004-01-01
A new Geographic Information System (GIS) method was developed as an alternative to the hand-counting of sinkholes on topographic maps for density and distribution studies. Sinkhole counts were prepared by hand and compared to those generated from USGS DLG data using ArcView 3.2 and the ArcInfo Workstation component of ArcGIS 8.1 software. The study area for this investigation, chosen for its great density of sinkholes, included the 42 public land survey sections that reside entirely within the Renault Quadrangle in southwestern Illinois. Differences between the sinkhole counts derived from the two methods for the Renault Quadrangle study area were negligible. Although the initial development and refinement of the GIS method required considerably more time than counting sinkholes by hand, the flexibility of the GIS method is expected to provide significant long-term benefits and time savings when mapping larger areas and expanding research efforts. ?? 2004 by The National Speleological Society.
A New Statistics-Based Online Baseline Restorer for a High Count-Rate Fully Digital System.
Li, Hongdi; Wang, Chao; Baghaei, Hossain; Zhang, Yuxuan; Ramirez, Rocio; Liu, Shitao; An, Shaohui; Wong, Wai-Hoi
2010-04-01
The goal of this work is to develop a novel, accurate, real-time digital baseline restorer using online statistical processing for a high count-rate digital system such as positron emission tomography (PET). In high count-rate nuclear instrumentation applications, analog signals are DC-coupled for better performance. However, the detectors, pre-amplifiers and other front-end electronics would cause a signal baseline drift in a DC-coupling system, which will degrade the performance of energy resolution and positioning accuracy. Event pileups normally exist in a high-count rate system and the baseline drift will create errors in the event pileup-correction. Hence, a baseline restorer (BLR) is required in a high count-rate system to remove the DC drift ahead of the pileup correction. Many methods have been reported for BLR from classic analog methods to digital filter solutions. However a single channel BLR with analog method can only work under 500 kcps count-rate, and normally an analog front-end application-specific integrated circuits (ASIC) is required for the application involved hundreds BLR such as a PET camera. We have developed a simple statistics-based online baseline restorer (SOBLR) for a high count-rate fully digital system. In this method, we acquire additional samples, excluding the real gamma pulses, from the existing free-running ADC in the digital system, and perform online statistical processing to generate a baseline value. This baseline value will be subtracted from the digitized waveform to retrieve its original pulse with zero-baseline drift. This method can self-track the baseline without a micro-controller involved. The circuit consists of two digital counter/timers, one comparator, one register and one subtraction unit. Simulation shows a single channel works at 30 Mcps count-rate with pileup condition. 336 baseline restorer circuits have been implemented into 12 field-programmable-gate-arrays (FPGA) for our new fully digital PET system.
NASA Astrophysics Data System (ADS)
Buongiorno, J.; Lloyd, K. G.; Shumaker, A.; Schippers, A.; Webster, G.; Weightman, A.; Turner, S.
2015-12-01
Nearly 75% of the Earth's surface is covered by marine sediment that is home to an estimated 2.9 x 1029 microbial cells. A substantial impediment to understanding the abundance and distribution of cells within marine sediment is the lack of a consistent and reliable method for their taxon-specific quantification. Catalyzed reporter fluorescent in situ hybridization (CARD-FISH) provides taxon-specific enumeration, but this process requires passing a large enzyme through cell membranes, decreasing its precision relative to general cell counts using a small DNA stain. In 2015, Yamaguchi et al. developed FISH hybridization chain reaction (FISH-HCR) as an in situ whole cell detection method for environmental microorganisms. FISH-HCR amplifies the fluorescent signal, as does CARD-FISH, but it allows for milder cell permeation methods that might prevent yield loss. To compare FISH-HCR to CARD-FISH, we examined bacteria and archaea cell counts within two sediment cores, Lille Belt (~78 meters deep) and Landsort Deep (90 meters deep), which were retrieved from the Baltic Sea Basin during IODP Expedition 347. Preliminary analysis shows that CARD-FISH counts are below the quantification limit for most depths across both cores. By contrast, quantification of cells was possible with FISH-HCR in all examined depths. When quantification with CARD-FISH was above the limit of detection, counts with FISH-HCR were up to 11 fold higher for Bacteria and 3 fold higher for Archaea from the same sediment sample. Further, FISH-HCR counts follow the trends of on board counts nicely, indicating that FISH-HCR may better reflect the cellular abundance within marine sediment than other quantification methods, including qPCR. Using FISH-HCR, we found that archaeal cell counts were on average greater than bacterial cell counts, but within the same order of magnitude.
Comparison of McMaster and FECPAKG2 methods for counting nematode eggs in the faeces of alpacas.
Rashid, Mohammed H; Stevenson, Mark A; Waenga, Shea; Mirams, Greg; Campbell, Angus J D; Vaughan, Jane L; Jabbar, Abdul
2018-05-02
This study aimed to compare the FECPAK G2 and the McMaster techniques for counting of gastrointestinal nematode eggs in the faeces of alpacas using two floatation solutions (saturated sodium chloride and sucrose solutions). Faecal eggs counts from both techniques were compared using the Lin's concordance correlation coefficient and Bland and Altman statistics. Results showed moderate to good agreement between the two methods, with better agreement achieved when saturated sugar is used as a floatation fluid, particularly when faecal egg counts are less than 1000 eggs per gram of faeces. To the best of our knowledge this is the first study to assess agreement of measurements between McMaster and FECPAK G2 methods for estimating faecal eggs in South American camelids.
Bowen, Michael E; Cavanaugh, Kerri L; Wolff, Kathleen; Davis, Dianne; Gregory, Rebecca P; Shintani, Ayumi; Eden, Svetlana; Wallston, Ken; Elasy, Tom; Rothman, Russell L
2016-08-01
To compare the effectiveness of different approaches to nutrition education in diabetes self-management education and support (DSME/S). We randomized 150 adults with type 2 diabetes to either certified diabetes educator (CDE)-delivered DSME/S with carbohydrate gram counting or the modified plate method versus general health education. The primary outcome was change in HbA1C over 6 months. At 6 months, HbA1C improved within the plate method [-0.83% (-1.29, -0.33), P<0.001] and carbohydrate counting [-0.63% (-1.03, -0.18), P=0.04] groups but not the control group [P=0.34]. Change in HbA1C from baseline between the control and intervention groups was not significant at 6 months (carbohydrate counting, P=0.36; modified plate method, P=0.08). In a pre-specified subgroup analysis of patients with a baseline HbA1C 7-10%, change in HbA1C from baseline improved in the carbohydrate counting [-0.86% (-1.47, -0.26), P=0.006] and plate method groups [-0.76% (-1.33, -0.19), P=0.01] compared to controls. CDE-delivered DSME/S focused on carbohydrate counting or the modified plate method improved glycemic control in patients with an initial HbA1C between 7 and 10%. Both carbohydrate counting and the modified plate method improve glycemic control as part of DSME/S. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Maltz, Jonathan S.
2000-11-01
We present an algorithm of reduced computational cost which is able to estimate kinetic model parameters directly from dynamic ECT sinograms made up of temporally inconsistent projections. The algorithm exploits the extreme degree of parameter redundancy inherent in linear combinations of the exponential functions which represent the modes of first-order compartmental systems. The singular value decomposition is employed to find a small set of orthogonal functions, the linear combinations of which are able to accurately represent all modes within the physiologically anticipated range in a given study. The reduced-dimension basis is formed as the convolution of this orthogonal set with a measured input function. The Moore-Penrose pseudoinverse is used to find coefficients of this basis. Algorithm performance is evaluated at realistic count rates using MCAT phantom and clinical 99mTc-teboroxime myocardial study data. Phantom data are modelled as originating from a Poisson process. For estimates recovered from a single slice projection set containing 2.5×105 total counts, recovered tissue responses compare favourably with those obtained using more computationally intensive methods. The corresponding kinetic parameter estimates (coefficients of the new basis) exhibit negligible bias, while parameter variances are low, falling within 30% of the Cramér-Rao lower bound.
Jizan, Iman; Helt, L. G.; Xiong, Chunle; Collins, Matthew J.; Choi, Duk-Yong; Joon Chae, Chang; Liscidini, Marco; Steel, M. J.; Eggleton, Benjamin J.; Clark, Alex S.
2015-01-01
The growing requirement for photon pairs with specific spectral correlations in quantum optics experiments has created a demand for fast, high resolution and accurate source characterisation. A promising tool for such characterisation uses classical stimulated processes, in which an additional seed laser stimulates photon generation yielding much higher count rates, as recently demonstrated for a χ(2) integrated source in A. Eckstein et al. Laser Photon. Rev. 8, L76 (2014). In this work we extend these results to χ(3) integrated sources, directly measuring for the first time the relation between spectral correlation measurements via stimulated and spontaneous four wave mixing in an integrated optical waveguide, a silicon nanowire. We directly confirm the speed-up due to higher count rates and demonstrate that this allows additional resolution to be gained when compared to traditional coincidence measurements without any increase in measurement time. As the pump pulse duration can influence the degree of spectral correlation, all of our measurements are taken for two different pump pulse widths. This allows us to confirm that the classical stimulated process correctly captures the degree of spectral correlation regardless of pump pulse duration, and cements its place as an essential characterisation method for the development of future quantum integrated devices. PMID:26218609
Chan, Leo Li-Ying; Laverty, Daniel J; Smith, Tim; Nejad, Parham; Hei, Hillary; Gandhi, Roopali; Kuksin, Dmitry; Qiu, Jean
2013-02-28
Peripheral blood mononuclear cells (PBMCs) have been widely researched in the fields of immunology, infectious disease, oncology, transplantation, hematological malignancy, and vaccine development. Specifically, in immunology research, PBMCs have been utilized to monitor concentration, viability, proliferation, and cytokine production from immune cells, which are critical for both clinical trials and biomedical research. The viability and concentration of isolated PBMCs are traditionally measured by manual counting with trypan blue (TB) using a hemacytometer. One of the common issues of PBMC isolation is red blood cell (RBC) contamination. The RBC contamination can be dependent on the donor sample and/or technical skill level of the operator. RBC contamination in a PBMC sample can introduce error to the measured concentration, which can pass down to future experimental assays performed on these cells. To resolve this issue, RBC lysing protocol can be used to eliminate potential error caused by RBC contamination. In the recent years, a rapid fluorescence-based image cytometry system has been utilized for bright-field and fluorescence imaging analysis of cellular characteristics (Nexcelom Bioscience LLC, Lawrence, MA). The Cellometer image cytometry system has demonstrated the capability of automated concentration and viability detection in disposable counting chambers of unpurified mouse splenocytes and PBMCs stained with acridine orange (AO) and propidium iodide (PI) under fluorescence detection. In this work, we demonstrate the ability of Cellometer image cytometry system to accurately measure PBMC concentration, despite RBC contamination, by comparison of five different total PBMC counting methods: (1) manual counting of trypan blue-stained PBMCs in hemacytometer, (2) manual counting of PBMCs in bright-field images, (3) manual counting of acetic acid lysing of RBCs with TB-stained PBMCs, (4) automated counting of acetic acid lysing of RBCs with PI-stained PBMCs, and (5) AO/PI dual staining method. The results show comparable total PBMC counting among all five methods, which validate the AO/PI staining method for PBMC measurement in the image cytometry method. Copyright © 2012 Elsevier B.V. All rights reserved.
Traffic effects on bird counts on North American Breeding Bird Survey routes
Griffith, Emily H.; Sauer, John R.; Royle, J. Andrew
2010-01-01
The North American Breeding Bird Survey (BBS) is an annual roadside survey used to estimate population change in >420 species of birds that breed in North America. Roadside sampling has been criticized, in part because traffic noise can interfere with bird counts. Since 1997, data have been collected on the numbers of vehicles that pass during counts at each stop. We assessed the effect of traffic by modeling total vehicles as a covariate of counts in hierarchical Poisson regression models used to estimate population change. We selected species for analysis that represent birds detected at low and high abundance and birds with songs of low and high frequencies. Increases in vehicle counts were associated with decreases in bird counts in most of the species examined. The size and direction of these effects remained relatively constant between two alternative models that we analyzed. Although this analysis indicated only a small effect of incorporating traffic effects when modeling roadside counts of birds, we suggest that continued evaluation of changes in traffic at BBS stops should be a component of future BBS analyses.
Count distribution for mixture of two exponentials as renewal process duration with applications
NASA Astrophysics Data System (ADS)
Low, Yeh Ching; Ong, Seng Huat
2016-06-01
A count distribution is presented by considering a renewal process where the distribution of the duration is a finite mixture of exponential distributions. This distribution is able to model over dispersion, a feature often found in observed count data. The computation of the probabilities and renewal function (expected number of renewals) are examined. Parameter estimation by the method of maximum likelihood is considered with applications of the count distribution to real frequency count data exhibiting over dispersion. It is shown that the mixture of exponentials count distribution fits over dispersed data better than the Poisson process and serves as an alternative to the gamma count distribution.
Effects of Agronomic Treatments on Structure and Function of Ammonia-Oxidizing Communities
Phillips, Carol J.; Harris, Dave; Dollhopf, Sherry L.; Gross, Katherine L.; Prosser, James I.; Paul, Eldor A.
2000-01-01
The aim of this study was to determine the effects of different agricultural treatments and plant communities on the diversity of ammonia oxidizer populations in soil. Denaturing gradient gel electrophoresis (DGGE), coupled with specific oligonucleotide probing, was used to analyze 16S rRNA genes of ammonia oxidizers belonging to the β subgroup of the division Proteobacteria by use of DNA extracted from cultivated, successional, and native deciduous forest soils. Community profiles of the different soil types were compared with nitrification rates and most-probable-number (MPN) counts. Despite significant variation in measured nitrification rates among communities, there were no differences in the DGGE banding profiles of DNAs extracted from these soils. DGGE profiles of DNA extracted from samples of MPN incubations, cultivated at a range of ammonia concentrations, showed the presence of bands not amplified from directly extracted DNA. Nitrosomonas-like bands were seen in the MPN DNA but were not detected in the DNA extracted directly from soils. These bands were detected in some samples taken from MPN incubations carried out with medium containing 1,000 μg of NH4+-N ml−1, to the exclusion of bands detected in the native DNA. Cell concentrations of ammonia oxidizers determined by MPN counts were between 10- and 100-fold lower than those determined by competitive PCR (cPCR). Although no differences were seen in ammonia oxidizer MPN counts from the different soil treatments, cPCR revealed higher numbers in fertilized soils. The use of a combination of traditional and molecular methods to investigate the activities and compositions of ammonia oxidizers in soil demonstrates differences in fine-scale compositions among treatments that may be associated with changes in population size and function. PMID:11097922
Lipid biomarker analysis for the quantitative analysis of airborne microorganisms
DOE Office of Scientific and Technical Information (OSTI.GOV)
Macnaughton, S.J.; Jenkins, T.L.; Cormier, M.R.
1997-08-01
There is an ever increasing concern regarding the presence of airborne microbial contaminants within indoor air environments. Exposure to such biocontaminants can give rise to large numbers of different health effects including infectious diseases, allergenic responses and respiratory problems, Biocontaminants typically round in indoor air environments include bacteria, fungi, algae, protozoa and dust mites. Mycotoxins, endotoxins, pollens and residues of organisms are also known to cause adverse health effects. A quantitative detection/identification technique independent of culturability that assays both culturable and non culturable biomass including endotoxin is critical in defining risks from indoor air biocontamination. Traditionally, methods employed for themore » monitoring of microorganism numbers in indoor air environments involve classical culture based techniques and/or direct microscopic counting. It has been repeatedly documented that viable microorganism counts only account for between 0.1-10% of the total community detectable by direct counting. The classic viable microbiologic approach doe`s not provide accurate estimates of microbial fragments or other indoor air components that can act as antigens and induce or potentiate allergic responses. Although bioaerosol samplers are designed to damage the microbes as little as possible, microbial stress has been shown to result from air sampling, aerosolization and microbial collection. Higher collection efficiency results in greater cell damage while less cell damage often results in lower collection efficiency. Filtration can collect particulates at almost 100% efficiency, but captured microorganisms may become dehydrated and damaged resulting in non-culturability, however, the lipid biomarker assays described herein do not rely on cell culture. Lipids are components that are universally distributed throughout cells providing a means to assess independent of culturability.« less
MONICA: A Compact, Portable Dual Gamma Camera System for Mouse Whole-Body Imaging
Xi, Wenze; Seidel, Jurgen; Karkareka, John W.; Pohida, Thomas J.; Milenic, Diane E.; Proffitt, James; Majewski, Stan; Weisenberger, Andrew G.; Green, Michael V.; Choyke, Peter L.
2009-01-01
Introduction We describe a compact, portable dual-gamma camera system (named “MONICA” for MObile Nuclear Imaging CAmeras) for visualizing and analyzing the whole-body biodistribution of putative diagnostic and therapeutic single photon emitting radiotracers in animals the size of mice. Methods Two identical, miniature pixelated NaI(Tl) gamma cameras were fabricated and installed “looking up” through the tabletop of a compact portable cart. Mice are placed directly on the tabletop for imaging. Camera imaging performance was evaluated with phantoms and field performance was evaluated in a weeklong In-111 imaging study performed in a mouse tumor xenograft model. Results Tc-99m performance measurements, using a photopeak energy window of 140 keV ± 10%, yielded the following results: spatial resolution (FWHM at 1-cm), 2.2-mm; sensitivity, 149 cps/MBq (5.5 cps/μCi); energy resolution (FWHM), 10.8%; count rate linearity (count rate vs. activity), r2 = 0.99 for 0–185 MBq (0–5 mCi) in the field-of-view (FOV); spatial uniformity, < 3% count rate variation across the FOV. Tumor and whole-body distributions of the In-111 agent were well visualized in all animals in 5-minute images acquired throughout the 168-hour study period. Conclusion Performance measurements indicate that MONICA is well suited to whole-body single photon mouse imaging. The field study suggests that inter-device communications and user-oriented interfaces included in the MONICA design facilitate use of the system in practice. We believe that MONICA may be particularly useful early in the (cancer) drug development cycle where basic whole-body biodistribution data can direct future development of the agent under study and where logistical factors, e.g. limited imaging space, portability, and, potentially, cost are important. PMID:20346864
Suzuki, Yoshihiro; Teranishi, Kotaro; Matsuwaki, Tomonori; Nukazawa, Kei; Ogura, Yoshitoshi
2018-05-28
To determine the effects of bacteria pollution associated with a strong typhoon event and to assess the restoration of the normal bacterial flora, we used conventional filtration methods and nextgeneration sequencing of 16S rRNA genes to analyze the transition of fecal and total bacterial counts in water and core sand samples collected from a recreational beach. Immediately after the typhoon event, Escherichia coli counts increased to 82 CFU/100 g in the surface beach sand. E. coli was detected through the surface to sand 85-cm deep at the land side point (10-m land side from the high-water line). However, E. coli disappeared within a month from the land side point. The composition of the bacterial flora in the beach sand at the land point was directly influenced by the typhoon event. Pseudomonas was the most prevalent genus throughout the sand layers (0-102-cm deep) during the typhoon event. After 3 months, the population of Pseudomonas significantly decreased, and the predominant genus in the surface layer was Kaistobacter, although Pseudomonas was the major genus in the 17- to 85-cm layer. When the beach conditions stabilized, the number of pollutant Pseudomonas among the 10 most abundant genera decreased to lower than the limit of detection. The bacterial population of the sand was subsequently restored to the most populous pre-event orders at the land point. A land-side beach, where users directly contact the sand, was significantly affected by bacterial pollution caused by a strong typhoon event. We show here that the normal bacterial flora of the surface sand was restored within 1 month. Copyright © 2018 Elsevier B.V. All rights reserved.
Red Blood Cell Count Automation Using Microscopic Hyperspectral Imaging Technology.
Li, Qingli; Zhou, Mei; Liu, Hongying; Wang, Yiting; Guo, Fangmin
2015-12-01
Red blood cell counts have been proven to be one of the most frequently performed blood tests and are valuable for early diagnosis of some diseases. This paper describes an automated red blood cell counting method based on microscopic hyperspectral imaging technology. Unlike the light microscopy-based red blood count methods, a combined spatial and spectral algorithm is proposed to identify red blood cells by integrating active contour models and automated two-dimensional k-means with spectral angle mapper algorithm. Experimental results show that the proposed algorithm has better performance than spatial based algorithm because the new algorithm can jointly use the spatial and spectral information of blood cells.
How to Quantify Penile Corpus Cavernosum Structures with Histomorphometry: Comparison of Two Methods
Felix-Patrício, Bruno; De Souza, Diogo Benchimol; Gregório, Bianca Martins; Costa, Waldemar Silva; Sampaio, Francisco José
2015-01-01
The use of morphometrical tools in biomedical research permits the accurate comparison of specimens subjected to different conditions, and the surface density of structures is commonly used for this purpose. The traditional point-counting method is reliable but time-consuming, with computer-aided methods being proposed as an alternative. The aim of this study was to compare the surface density data of penile corpus cavernosum trabecular smooth muscle in different groups of rats, measured by two observers using the point-counting or color-based segmentation method. Ten normotensive and 10 hypertensive male rats were used in this study. Rat penises were processed to obtain smooth muscle immunostained histological slices and photomicrographs captured for analysis. The smooth muscle surface density was measured in both groups by two different observers by the point-counting method and by the color-based segmentation method. Hypertensive rats showed an increase in smooth muscle surface density by the two methods, and no difference was found between the results of the two observers. However, surface density values were higher by the point-counting method. The use of either method did not influence the final interpretation of the results, and both proved to have adequate reproducibility. However, as differences were found between the two methods, results obtained by either method should not be compared. PMID:26413547
Felix-Patrício, Bruno; De Souza, Diogo Benchimol; Gregório, Bianca Martins; Costa, Waldemar Silva; Sampaio, Francisco José
2015-01-01
The use of morphometrical tools in biomedical research permits the accurate comparison of specimens subjected to different conditions, and the surface density of structures is commonly used for this purpose. The traditional point-counting method is reliable but time-consuming, with computer-aided methods being proposed as an alternative. The aim of this study was to compare the surface density data of penile corpus cavernosum trabecular smooth muscle in different groups of rats, measured by two observers using the point-counting or color-based segmentation method. Ten normotensive and 10 hypertensive male rats were used in this study. Rat penises were processed to obtain smooth muscle immunostained histological slices and photomicrographs captured for analysis. The smooth muscle surface density was measured in both groups by two different observers by the point-counting method and by the color-based segmentation method. Hypertensive rats showed an increase in smooth muscle surface density by the two methods, and no difference was found between the results of the two observers. However, surface density values were higher by the point-counting method. The use of either method did not influence the final interpretation of the results, and both proved to have adequate reproducibility. However, as differences were found between the two methods, results obtained by either method should not be compared.
A Maximum NEC Criterion for Compton Collimation to Accurately Identify True Coincidences in PET
Chinn, Garry; Levin, Craig S.
2013-01-01
In this work, we propose a new method to increase the accuracy of identifying true coincidence events for positron emission tomography (PET). This approach requires 3-D detectors with the ability to position each photon interaction in multi-interaction photon events. When multiple interactions occur in the detector, the incident direction of the photon can be estimated using the Compton scatter kinematics (Compton Collimation). If the difference between the estimated incident direction of the photon relative to a second, coincident photon lies within a certain angular range around colinearity, the line of response between the two photons is identified as a true coincidence and used for image reconstruction. We present an algorithm for choosing the incident photon direction window threshold that maximizes the noise equivalent counts of the PET system. For simulated data, the direction window removed 56%–67% of random coincidences while retaining > 94% of true coincidences from image reconstruction as well as accurately extracted 70% of true coincidences from multiple coincidences. PMID:21317079
Rakvongthai, Yothin; Ouyang, Jinsong; Guerin, Bastien; Li, Quanzheng; Alpert, Nathaniel M.; El Fakhri, Georges
2013-01-01
Purpose: Our research goal is to develop an algorithm to reconstruct cardiac positron emission tomography (PET) kinetic parametric images directly from sinograms and compare its performance with the conventional indirect approach. Methods: Time activity curves of a NCAT phantom were computed according to a one-tissue compartmental kinetic model with realistic kinetic parameters. The sinograms at each time frame were simulated using the activity distribution for the time frame. The authors reconstructed the parametric images directly from the sinograms by optimizing a cost function, which included the Poisson log-likelihood and a spatial regularization terms, using the preconditioned conjugate gradient (PCG) algorithm with the proposed preconditioner. The proposed preconditioner is a diagonal matrix whose diagonal entries are the ratio of the parameter and the sensitivity of the radioactivity associated with parameter. The authors compared the reconstructed parametric images using the direct approach with those reconstructed using the conventional indirect approach. Results: At the same bias, the direct approach yielded significant relative reduction in standard deviation by 12%–29% and 32%–70% for 50 × 106 and 10 × 106 detected coincidences counts, respectively. Also, the PCG method effectively reached a constant value after only 10 iterations (with numerical convergence achieved after 40–50 iterations), while more than 500 iterations were needed for CG. Conclusions: The authors have developed a novel approach based on the PCG algorithm to directly reconstruct cardiac PET parametric images from sinograms, and yield better estimation of kinetic parameters than the conventional indirect approach, i.e., curve fitting of reconstructed images. The PCG method increases the convergence rate of reconstruction significantly as compared to the conventional CG method. PMID:24089922
Counting-loss correction for X-ray spectroscopy using unit impulse pulse shaping.
Hong, Xu; Zhou, Jianbin; Ni, Shijun; Ma, Yingjie; Yao, Jianfeng; Zhou, Wei; Liu, Yi; Wang, Min
2018-03-01
High-precision measurement of X-ray spectra is affected by the statistical fluctuation of the X-ray beam under low-counting-rate conditions. It is also limited by counting loss resulting from the dead-time of the system and pile-up pulse effects, especially in a high-counting-rate environment. In this paper a detection system based on a FAST-SDD detector and a new kind of unit impulse pulse-shaping method is presented, for counting-loss correction in X-ray spectroscopy. The unit impulse pulse-shaping method is evolved by inverse deviation of the pulse from a reset-type preamplifier and a C-R shaper. It is applied to obtain the true incoming rate of the system based on a general fast-slow channel processing model. The pulses in the fast channel are shaped to unit impulse pulse shape which possesses small width and no undershoot. The counting rate in the fast channel is corrected by evaluating the dead-time of the fast channel before it is used to correct the counting loss in the slow channel.
Zboromyrska, Y; Rubio, E; Alejo, I; Vergara, A; Mons, A; Campo, I; Bosch, J; Marco, F; Vila, J
2016-06-01
The current gold standard method for the diagnosis of urinary tract infections (UTI) is urine culture that requires 18-48 h for the identification of the causative microorganisms and an additional 24 h until the results of antimicrobial susceptibility testing (AST) are available. The aim of this study was to shorten the time of urine sample processing by a combination of flow cytometry for screening and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) for bacterial identification followed by AST directly from urine. The study was divided into two parts. During the first part, 675 urine samples were processed by a flow cytometry device and a cut-off value of bacterial count was determined to select samples for direct identification by MALDI-TOF-MS at ≥5 × 10(6) bacteria/mL. During the second part, 163 of 1029 processed samples reached the cut-off value. The sample preparation protocol for direct identification included two centrifugation and two washing steps. Direct AST was performed by the disc diffusion method if a reliable direct identification was obtained. Direct MALDI-TOF-MS identification was performed in 140 urine samples; 125 of the samples were positive by urine culture, 12 were contaminated and 3 were negative. Reliable direct identification was obtained in 108 (86.4%) of the 125 positive samples. AST was performed in 102 identified samples, and the results were fully concordant with the routine method among 83 monomicrobial infections. In conclusion, the turnaround time of the protocol described to diagnose UTI was about 1 h for microbial identification and 18-24 h for AST. Copyright © 2016 European Society of Clinical Microbiology and Infectious Diseases. Published by Elsevier Ltd. All rights reserved.
NASA Astrophysics Data System (ADS)
Grinyer, G. F.; Svensson, C. E.; Andreoiu, C.; Andreyev, A. N.; Austin, R. A. E.; Ball, G. C.; Bandyopadhyay, D.; Chakrawarthy, R. S.; Finlay, P.; Garrett, P. E.; Hackman, G.; Hyland, B.; Kulp, W. D.; Leach, K. G.; Leslie, J. R.; Morton, A. C.; Pearson, C. J.; Phillips, A. A.; Sarazin, F.; Schumaker, M. A.; Smith, M. B.; Valiente-Dobón, J. J.; Waddington, J. C.; Williams, S. J.; Wong, J.; Wood, J. L.; Zganjar, E. F.
2007-09-01
A general technique that corrects γ-ray gated β decay-curve data for detector pulse pile-up is presented. The method includes corrections for non-zero time-resolution and energy-threshold effects in addition to a special treatment of saturating events due to cosmic rays. This technique is verified through a Monte Carlo simulation and experimental data using radioactive beams of Na26 implanted at the center of the 8π γ-ray spectrometer at the ISAC facility at TRIUMF in Vancouver, Canada. The β-decay half-life of Na26 obtained from counting 1809-keV γ-ray photopeaks emitted by the daughter Mg26 was determined to be T=1.07167±0.00055 s following a 27σ correction for detector pulse pile-up. This result is in excellent agreement with the result of a previous measurement that employed direct β counting and demonstrates the feasibility of high-precision β-decay half-life measurements through the use of high-purity germanium γ-ray detectors. The technique presented here, while motivated by superallowed-Fermi β decay studies, is general and can be used for all half-life determinations (e.g. α-, β-, X-ray, fission) in which a γ-ray photopeak is used to select the decays of a particular isotope.
Gadolinium-loaded Plastic Scintillators for Thermal Neutron Detection using Compensation
NASA Astrophysics Data System (ADS)
Dumazert, Jonathan; Coulon, Romain; Hamel, Matthieu; Carrel, Frédérick; Sguerra, Fabien; Normand, Stéphane; Méchin, Laurence; Bertrand, Guillaume H. V.
2016-06-01
Plastic scintillator loading with gadolinium-rich organometallic complexes shows a high potential for the deployment of efficient and cost-effective neutron detectors. Due to the low-energy photon and electron signature of thermal neutron capture by Gd-155 and Gd-157, alternative treatment to pulse-shape discrimination has to be proposed in order to display a count rate. This paper discloses the principle of a compensation method applied to a two-scintillator system: a detection scintillator interacts with photon and fast neutron radiation and is loaded with gadolinium organometallic compound to become a thermal neutron absorber, while a not-gadolinium loaded compensation scintillator solely interacts with the fast neutron and photon part of incident radiation. After the nonlinear smoothing of the counting signals, a hypothesis test determines whether the resulting count rate post-background response compensation falls into statistical fluctuations or provides a robust indication of neutron activity. Laboratory samples are tested under both photon and neutron irradiations, allowing the authors to investigate the performance of the overall detection system in terms of sensitivity and detection limits, especially with regards to a similar-active volume He-3 based commercial counter. The study reveals satisfactory figures of merit in terms of sensitivity and directs future investigation toward promising paths.
DOE Office of Scientific and Technical Information (OSTI.GOV)
Fliermans, C.B.; Dougherty, J.M.; Franck, M.M.
Effective in situ bioremediation strategies require an understanding of the effects pollutants and remediation techniques have on subsurface microbial communities. Therefore, detailed characterization of a site`s microbial communities is important. Subsurface sediment borings and water samples were collected from a trichloroethylene (TCE) contaminated site, before and after horizontal well in situ air stripping and bioventing, as well as during methane injection for stimulation of methane-utilizing microorganisms. Subsamples were processed for heterotrophic plate counts, acridine orange direct counts (AODC), community diversity, direct fluorescent antibodies (DFA) enumeration for several nitrogen-transforming bacteria, and Biolog {reg_sign} evaluation of enzyme activity in collected water samples.more » Plate counts were higher in near-surface depths than in the vadose zone sediment samples. During the in situ air stripping and bioventing, counts increased at or near the saturated zone, remained elevated throughout the aquifer, but did not change significantly after the air stripping. Sporadic increases in plate counts at different depths as well as increased diversity appeared to be linked to differing lithologies. AODCs were orders of magnitude higher than plate counts and remained relatively constant with depth except for slight increases near the surface depths and the capillary fringe. Nitrogen-transforming bacteria, as measured by serospecific DFA, were greatly affected both by the in situ air stripping and the methane injection. Biolog{reg_sign} activity appeared to increase with subsurface stimulation both by air and methane. The complexity of subsurface systems makes the use of selective monitoring tools imperative.« less
Minimizing the Delay at Traffic Lights
ERIC Educational Resources Information Center
Van Hecke, Tanja
2009-01-01
Vehicles holding at traffic lights is a typical queuing problem. At crossings the vehicles experience delay in both directions. Longer periods with green lights in one direction are disadvantageous for the vehicles coming from the other direction. The total delay for getting through the traffic point is what counts. This article presents an…
Systematic wavelength selection for improved multivariate spectral analysis
Thomas, Edward V.; Robinson, Mark R.; Haaland, David M.
1995-01-01
Methods and apparatus for determining in a biological material one or more unknown values of at least one known characteristic (e.g. the concentration of an analyte such as glucose in blood or the concentration of one or more blood gas parameters) with a model based on a set of samples with known values of the known characteristics and a multivariate algorithm using several wavelength subsets. The method includes selecting multiple wavelength subsets, from the electromagnetic spectral region appropriate for determining the known characteristic, for use by an algorithm wherein the selection of wavelength subsets improves the model's fitness of the determination for the unknown values of the known characteristic. The selection process utilizes multivariate search methods that select both predictive and synergistic wavelengths within the range of wavelengths utilized. The fitness of the wavelength subsets is determined by the fitness function F=.function.(cost, performance). The method includes the steps of: (1) using one or more applications of a genetic algorithm to produce one or more count spectra, with multiple count spectra then combined to produce a combined count spectrum; (2) smoothing the count spectrum; (3) selecting a threshold count from a count spectrum to select these wavelength subsets which optimize the fitness function; and (4) eliminating a portion of the selected wavelength subsets. The determination of the unknown values can be made: (1) noninvasively and in vivo; (2) invasively and in vivo; or (3) in vitro.
Cwiklińska, Agnieszka; Kąkol, Judyta; Kuchta, Agnieszka; Kortas-Stempak, Barbara; Pacanis, Anastasis; Rogulski, Jerzy; Wróblewska, Małgorzata
2012-02-01
Given the common problems with the standardization of urine particle counting methods and the great variability in the results obtained by Polish laboratories under international Labquality External Quality Assessment (EQA), we initiated educational recovery activities. Detailed instructions on how to perform the standardized examination were sent to EQA participants, as was a questionnaire forms which enabled information to be gathered in respect to the procedures being applied. Laboratory results were grouped according to the method declared on the EQA 'Result' form or according to a manual examination procedure established on the basis of the questionnaire. The between-laboratory CVs for leukocyte and erythrocyte counts were calculated for each group and compared using the Mann-Whitney test. Significantly lower between-laboratory CVs (p = 0.03) were achieved for leukocyte counting among the laboratories that analysed control specimens in accordance with standardized procedures as compared with those which used non-standardized procedures. We also observed a visible lower variability for erythrocyte counting. Unfortunately despite our activities, only a few of the Polish laboratories applied the standardized examination procedures, and only 29% of the results could have been considered to be standardized (16% - manual methods, 13% - automated systems). The standardization of urine particle counting methods continues to be a significant problem in medical laboratories and requires further recovery activities which can be conducted using the EQA scheme.
Bottomley, Peter J.; Dughri, Muktar H.
1989-01-01
Bacterial cells small enough to pass through 0.4-μm-pore-size filters made up 5 to 9% of the indigenous bacterial population in 0- to 20-cm-depth samples of Abiqua silty clay loam. Within the same soil samples, cells of a similar dimension were stained with fluorescent antibodies specific to each of four antigenically distinct indigenous serogroups of Rhizobium leguminosarum bv. trifolii and made up 22 to 34% of the soil population of the four serogroups. Despite the extensive contribution of small cells to these soil populations, no evidence of their being capable of either growth or nodulation was obtained. The density of soil bacteria which could be cultured ranged between 0.5 and 8.5% of the >0.4-μm direct count regardless of media, season of sampling, or soil depth. In the same soil samples, the viable nodulating populations of biovar trifolii determined by the plant infection soil dilution technique ranged between 1 and 10% of the >0.4-μm direct-immunofluorescence count of biovar trifolii. The <0.4-μm cell populations of both total soil bacteria and biovar trifolii changed abruptly between the 10- to 15-cm and 15- to 20-cm soil depth increments, increasing from 5 to 20% and from 20 to 50%, respectively, of their direct-count totals. The increase in density of the small-cell population corresponded to a significant increase in soil bulk density (1.07 to 1.21 g cm−3). The percent contribution of the <0.4-μm direct count to individual serogroup totals increased with soil depth by approximately 2-fold (39 to 87%) for serogroups 17 and 21 and by 12-fold (6 to 75%) for serogroups 6 and 36. PMID:16347896
Ren, Jie; Song, Kai; Deng, Minghua; Reinert, Gesine; Cannon, Charles H; Sun, Fengzhu
2016-04-01
Next-generation sequencing (NGS) technologies generate large amounts of short read data for many different organisms. The fact that NGS reads are generally short makes it challenging to assemble the reads and reconstruct the original genome sequence. For clustering genomes using such NGS data, word-count based alignment-free sequence comparison is a promising approach, but for this approach, the underlying expected word counts are essential.A plausible model for this underlying distribution of word counts is given through modeling the DNA sequence as a Markov chain (MC). For single long sequences, efficient statistics are available to estimate the order of MCs and the transition probability matrix for the sequences. As NGS data do not provide a single long sequence, inference methods on Markovian properties of sequences based on single long sequences cannot be directly used for NGS short read data. Here we derive a normal approximation for such word counts. We also show that the traditional Chi-square statistic has an approximate gamma distribution ,: using the Lander-Waterman model for physical mapping. We propose several methods to estimate the order of the MC based on NGS reads and evaluate those using simulations. We illustrate the applications of our results by clustering genomic sequences of several vertebrate and tree species based on NGS reads using alignment-free sequence dissimilarity measures. We find that the estimated order of the MC has a considerable effect on the clustering results ,: and that the clustering results that use a N: MC of the estimated order give a plausible clustering of the species. Our implementation of the statistics developed here is available as R package 'NGS.MC' at http://www-rcf.usc.edu/∼fsun/Programs/NGS-MC/NGS-MC.html fsun@usc.edu Supplementary data are available at Bioinformatics online. © The Author 2015. Published by Oxford University Press. All rights reserved. For Permissions, please e-mail: journals.permissions@oup.com.
Evaluation of CP Chromo Select Agar for the enumeration of Clostridium perfringens from water.
Manafi, Mammad; Waldherr, Kerstin; Kundi, Michael
2013-10-01
The European Directive on drinking water quality has included mCP agar as the reference method for recovering Clostridium perfringens from drinking waters. In the present study, three media (mCP, TSCF and CP Chromo Select Agar) were evaluated for recovery of C. perfringens in different surface water samples. Out of 139 water samples, using a membrane filtration technique, 131 samples (94.2%) were found to be presumptively positive for C. perfringens in at least one of the culture media. Green colored colonies on CP Chromo Select Agar (CCP agar) were counted as presumptive C. perfringens isolates. Out of 483 green colonies on CCP agar, 96.3% (465 strains, indole negative) were identified as C. perfringens, and 15 strains (3.1%) were indole positive and were identified as Clostridium sordellii, Clostridium bifermentans or Clostridium tetani. Only 3 strains (0.6%) gave false positive results and were identified as Clostridium fallax, Clostridium botulinum, and Clostridium tertium. Variance analysis of the data obtained shows statistically no significant differences in the counts obtained between media employed in this work. The mCP method is very onerous for routine screening and bacterial colonies could not be used for further biochemical testing. The colonies on CCP and TSCF were easy to count and subculture for confirmation tests. TSCF detects sulfite-reducing clostridia, including species other than C. perfringens, and in some cases excessive blackening of the agar frustrated counting of the colonies. If the contamination was too high, TSCF did not consistently produce black colonies and as a consequence, the colonies were white and gave false negative results. On the other hand, the identification of typical and atypical colonies isolated from all media demonstrated that CCP agar was the most useful medium for C. perfringens recovery in water samples. Copyright © 2013 Elsevier B.V. All rights reserved.
Champagne, C P; Raymond, Y; Gonthier, J; Audet, P
2009-04-01
Pasteurized and unfermented milks supplemented with probiotic bacteria are appearing on the market. It then becomes a challenge to ascertain the undesirable contamination microbiota in the presence of a largely superior population of probiotic bacteria. A method to enumerate the contaminating microbial microbiota in such probiotic-enriched milks was developed. The probiotic cultures, Lactobacillus rhamnosus Lb-Immuni-T and Bifidobacterium animalis subsp. lactis BB-12(R), were added to a pasteurized unfermented milk to reach a minimum of 1 billion CFU per 250 mL portion, as ascertained by plating on de Man - Rogosa - Sharpe (MRS) agar in anaerobic conditions. No growth of B. animalis subsp. lactis BB-12 was noted on plate count agar (PCA) or Petrifilm plates, and the presence of this culture did not affect standard plate counts (SPC) of contaminating bacteria. However, L. rhamnosus formed colonies on PCA and Petrifilm plates. Attempts were thus made to inhibit the growth of the probiotic lactobacilli in PCA. The addition of 2% sodium phosphate (SP) or 5% glycerophosphate (GP) inhibited the growth of the lactobacilli in broths, but pin-point colonies of L. rhamnosus Lb-Immuni-T nevertheless appeared on PCA supplemented with phosphates. SPC could be obtained on PCA + 2% SP by only counting the large colonies, but this resulted in a significant (4.4 fold) underestimation of SPC values. On Petrifilm AC, at dilutions 0 to 2, all colonies were considered as being contaminants, while at dilutions 3 and 4, only large colonies were counted for SPC determinations. There was a direct correlation (R2 = 0.99) between SPC values with Petrifilm in uninoculated milks and those obtained on probiotic-enriched milks. The high correlation obtained over the 102 to 106 CFU/mL range of SPC values show that this Petrifilm method is appropriate to evaluate the microbiological quality of pasteurized milks enriched with L. rhamnosus Lb-Immuni-T and B. animalis subsp. lactis BB-12.
Briët, Olivier J. T.; Amerasinghe, Priyanie H.; Vounatsou, Penelope
2013-01-01
Introduction With the renewed drive towards malaria elimination, there is a need for improved surveillance tools. While time series analysis is an important tool for surveillance, prediction and for measuring interventions’ impact, approximations by commonly used Gaussian methods are prone to inaccuracies when case counts are low. Therefore, statistical methods appropriate for count data are required, especially during “consolidation” and “pre-elimination” phases. Methods Generalized autoregressive moving average (GARMA) models were extended to generalized seasonal autoregressive integrated moving average (GSARIMA) models for parsimonious observation-driven modelling of non Gaussian, non stationary and/or seasonal time series of count data. The models were applied to monthly malaria case time series in a district in Sri Lanka, where malaria has decreased dramatically in recent years. Results The malaria series showed long-term changes in the mean, unstable variance and seasonality. After fitting negative-binomial Bayesian models, both a GSARIMA and a GARIMA deterministic seasonality model were selected based on different criteria. Posterior predictive distributions indicated that negative-binomial models provided better predictions than Gaussian models, especially when counts were low. The G(S)ARIMA models were able to capture the autocorrelation in the series. Conclusions G(S)ARIMA models may be particularly useful in the drive towards malaria elimination, since episode count series are often seasonal and non-stationary, especially when control is increased. Although building and fitting GSARIMA models is laborious, they may provide more realistic prediction distributions than do Gaussian methods and may be more suitable when counts are low. PMID:23785448
Are Indirect Benefits Relevant to Health Care Allocation Decisions?
Du Toit, Jessica; Millum, Joseph
2016-01-01
Abstract When allocating scarce healthcare resources, the expected benefits of alternative allocations matter. But, there are different kinds of benefits. Some are direct benefits to the recipient of the resource such as the health improvements of receiving treatment. Others are indirect benefits to third parties such as the economic gains from having a healthier workforce. This article considers whether only the direct benefits of alternative healthcare resource allocations are relevant to allocation decisions, or whether indirect benefits are relevant too. First, we distinguish different conceptions of direct and indirect benefits and argue that only a recipient conception could be morally relevant. We analyze four arguments for thinking that indirect benefits should not count and argue that none is successful in showing that the indirectness of a benefit is a good reason not to count it. We conclude that direct and indirect benefits should be evaluated in the same way. PMID:27465773
Wang, WeiBo; Sun, Wei; Wang, Wei; Szatkiewicz, Jin
2018-03-01
The application of high-throughput sequencing in a broad range of quantitative genomic assays (e.g., DNA-seq, ChIP-seq) has created a high demand for the analysis of large-scale read-count data. Typically, the genome is divided into tiling windows and windowed read-count data is generated for the entire genome from which genomic signals are detected (e.g. copy number changes in DNA-seq, enrichment peaks in ChIP-seq). For accurate analysis of read-count data, many state-of-the-art statistical methods use generalized linear models (GLM) coupled with the negative-binomial (NB) distribution by leveraging its ability for simultaneous bias correction and signal detection. However, although statistically powerful, the GLM+NB method has a quadratic computational complexity and therefore suffers from slow running time when applied to large-scale windowed read-count data. In this study, we aimed to speed up substantially the GLM+NB method by using a randomized algorithm and we demonstrate here the utility of our approach in the application of detecting copy number variants (CNVs) using a real example. We propose an efficient estimator, the randomized GLM+NB coefficients estimator (RGE), for speeding up the GLM+NB method. RGE samples the read-count data and solves the estimation problem on a smaller scale. We first theoretically validated the consistency and the variance properties of RGE. We then applied RGE to GENSENG, a GLM+NB based method for detecting CNVs. We named the resulting method as "R-GENSENG". Based on extensive evaluation using both simulated and empirical data, we concluded that R-GENSENG is ten times faster than the original GENSENG while maintaining GENSENG's accuracy in CNV detection. Our results suggest that RGE strategy developed here could be applied to other GLM+NB based read-count analyses, i.e. ChIP-seq data analysis, to substantially improve their computational efficiency while preserving the analytic power.
2015-01-01
Single molecule fluorescence spectroscopy holds the promise of providing direct measurements of protein folding free energy landscapes and conformational motions. However, fulfilling this promise has been prevented by technical limitations, most notably, the difficulty in analyzing the small packets of photons per millisecond that are typically recorded from individual biomolecules. Such limitation impairs the ability to accurately determine conformational distributions and resolve sub-millisecond processes. Here we develop an analytical procedure for extracting the conformational distribution and dynamics of fast-folding proteins directly from time-stamped photon arrival trajectories produced by single molecule FRET experiments. Our procedure combines the maximum likelihood analysis originally developed by Gopich and Szabo with a statistical mechanical model that describes protein folding as diffusion on a one-dimensional free energy surface. Using stochastic kinetic simulations, we thoroughly tested the performance of the method in identifying diverse fast-folding scenarios, ranging from two-state to one-state downhill folding, as a function of relevant experimental variables such as photon count rate, amount of input data, and background noise. The tests demonstrate that the analysis can accurately retrieve the original one-dimensional free energy surface and microsecond folding dynamics in spite of the sub-megahertz photon count rates and significant background noise levels of current single molecule fluorescence experiments. Therefore, our approach provides a powerful tool for the quantitative analysis of single molecule FRET experiments of fast protein folding that is also potentially extensible to the analysis of any other biomolecular process governed by sub-millisecond conformational dynamics. PMID:25988351
Ramanathan, Ravishankar; Muñoz, Victor
2015-06-25
Single molecule fluorescence spectroscopy holds the promise of providing direct measurements of protein folding free energy landscapes and conformational motions. However, fulfilling this promise has been prevented by technical limitations, most notably, the difficulty in analyzing the small packets of photons per millisecond that are typically recorded from individual biomolecules. Such limitation impairs the ability to accurately determine conformational distributions and resolve sub-millisecond processes. Here we develop an analytical procedure for extracting the conformational distribution and dynamics of fast-folding proteins directly from time-stamped photon arrival trajectories produced by single molecule FRET experiments. Our procedure combines the maximum likelihood analysis originally developed by Gopich and Szabo with a statistical mechanical model that describes protein folding as diffusion on a one-dimensional free energy surface. Using stochastic kinetic simulations, we thoroughly tested the performance of the method in identifying diverse fast-folding scenarios, ranging from two-state to one-state downhill folding, as a function of relevant experimental variables such as photon count rate, amount of input data, and background noise. The tests demonstrate that the analysis can accurately retrieve the original one-dimensional free energy surface and microsecond folding dynamics in spite of the sub-megahertz photon count rates and significant background noise levels of current single molecule fluorescence experiments. Therefore, our approach provides a powerful tool for the quantitative analysis of single molecule FRET experiments of fast protein folding that is also potentially extensible to the analysis of any other biomolecular process governed by sub-millisecond conformational dynamics.
Vanden Eng, Jodi L; Mathanga, Don P; Landman, Keren; Mwandama, Dyson; Minta, Anna A; Shah, Monica; Sutcliffe, James; Chisaka, Joseph; Lindblade, Kim A; Steinhardt, Laura
2017-10-10
Measuring the physical condition of long-lasting insecticidal nets (LLINs) under field conditions is of great importance for malaria control programmes to guide decisions on how frequently to replace LLINs. Current guidelines by the World Health Organization Pesticide Evaluation Scheme (WHOPES) propose a proportionate hole index (pHI) for assessing LLIN condition by counting the number of holes the size of a thumb, fist, head, and larger than a head. However, this method does not account for irregular hole shapes or exact hole sizes which could result in inaccurate decisions about when to replace LLINs. LLINs were collected during a 2013 health facility-based malaria case control study in Machinga District, Malawi. To evaluate the accuracy of the pHI, the physical condition of 277 LLINs was estimated by the WHOPES method and then compared with two more thorough measurement methods: image analysis of digital photographs of each LLIN side; and for 10 nets, ruler measurements of the length, width, and location of each hole. Total hole counts and areas per net were estimated by each method, and detailed results of hole shapes and composite pictures of hole locations were generated using image analysis. The WHOPES method and image analysis resulted in similar estimates of total hole counts, each with a median of 10 (inter-quartile range (IQR) 4-24 and 4-23, respectively; p = 0.004); however, estimated hole areas were significantly larger using the WHOPES method (median 162 cm 2 , IQR 28-793) than image analysis (median 13 cm 2 , IQR 3-101; p < 0.0001). The WHOPES method classified fewer LLINs in 'good condition' compared to image analysis (42% vs 74%). The ruler method detected significantly more holes than image analysis did (p = 0.002) in 10 LLINs; however, total hole area was not significantly different (p = 0.16). Most holes were not circular but roughly 2-5 times longer in one direction. The lower quarter of LLIN sides was found to have the most holes. The WHOPES method overestimated total hole area, likely because holes are elongated rather than circular, suggesting further adjustments to the pHI formula may be warranted when considering LLIN replacement strategies.
Souto, Débora Lopes; Zajdenverg, Lenita; Rodacki, Melanie; Rosado, Eliane Lopes
2014-03-01
Diets based on carbohydrate counting remain a key strategy for improving glycemic control in patients with type 1 diabetes. However, these diets may promote weight gain because of the flexibility in food choices. The aim of this study was to compare carbohydrate counting methods regarding anthropometric, biochemical, and dietary variables in individuals with type 1 diabetes, as well as to evaluate their knowledge about nutrition. Participants were allocated in basic or advanced groups. After 3 mo of the nutritional counseling, dietary intake, anthropometric variables, lipemia, and glycemic control were compared between groups. A questionnaire regarding carbohydrate counting, sucrose intake, nutritional knowledge, and diabetes and nutrition taboos also was administered. Ten (30%) participants had already used advanced carbohydrate counting before the nutritional counseling and these individuals had a higher body mass index (BMI) (P < 0.01) and waist circumference (WC) (P = 0.01) than others (n = 23; 69.7%). After 3 mo of follow-up, although participants in the advanced group (n = 17; 51.52%) presented higher BMI (P < 0.01) and WC (P = 0.03), those in the basic group (n = 16; 48.48%) showed a higher fat intake (P < 0.01). The majority of participants reported no difficulty in following carbohydrate counting (62.5% and 88% for basic and advanced groups, respectively) and a greater flexibility in terms of food choices (>90% with both methods). Advanced carbohydrate counting did not affect lipemic and glycemic control in individuals with type 1 diabetes, however, it may increase food intake, and consequently the BMI and WC, when compared to basic carbohydrate counting. Furthermore, carbohydrate counting promoted greater food flexibility. Copyright © 2014 Elsevier Inc. All rights reserved.
Bassiouny, M R; El-Chennawi, F; Mansour, A K; Yahia, S; Darwish, A
2015-06-01
Umbilical cord blood (UCB) contains stem cells and can be used as an alternative to bone marrow transplantation. Engraftment is dependent on the total nucleated cell (TNC) and CD34+ cell counts of the cord blood units. This study was designed to evaluate the effect of the method of collection of the UCB on the yield of the cord blood units. Informed consent was obtained from 100 eligible mothers for donation of cord blood. Both in utero and ex utero methods were used for collection. The cord blood volume was measured. The TNC and the CD34+ cell counts were enumerated. We have found that in utero collection gave significantly larger volumes of cord blood and higher TNC counts than ex utero collection. There was no significant difference between both methods regarding the CD34+ cell counts. This study revealed a significant correlation between the volume of the collected cord blood and both TNC and CD34+ cell counts. It is better to collect cord blood in utero before placental delivery to optimize the quality of the cord blood unit. © 2015 AABB.
Optimisation of nasal swab analysis by liquid scintillation counting.
Dai, Xiongxin; Liblong, Aaron; Kramer-Tremblay, Sheila; Priest, Nicholas; Li, Chunsheng
2012-06-01
When responding to an emergency radiological incident, rapid methods are needed to provide the physicians and radiation protection personnel with an early estimation of possible internal dose resulting from the inhalation of radionuclides. This information is needed so that appropriate medical treatment and radiological protection control procedures can be implemented. Nasal swab analysis, which employs swabs swiped inside a nostril followed by liquid scintillation counting of alpha and beta activity on the swab, could provide valuable information to quickly identify contamination of the affected population. In this study, various parameters (such as alpha/beta discrimination, swab materials, counting time and volume of scintillation cocktail etc) were evaluated in order to optimise the effectiveness of the nasal swab analysis method. An improved nasal swab procedure was developed by replacing cotton swabs with polyurethane-tipped swabs. Liquid scintillation counting was performed using a Hidex 300SL counter with alpha/beta pulse shape discrimination capability. Results show that the new method is more reliable than existing methods using cotton swabs and effectively meets the analysis requirements for screening personnel in an emergency situation. This swab analysis procedure is also applicable to wipe tests of surface contamination to minimise the source self-absorption effect on liquid scintillation counting.
Earthquake dating: an application of carbon-14 atom counting.
Tucker, A B; Woefli, W; Bonani, G; Suter, M
1983-03-18
Milligram-sized specimens of detrital charcoal from soil layers associated with prehistoric earthquakes on the Wasatch fault in Utah have been dated by direct atom counting of carbon-14 with a tandem Van de Graaff accelerator. The measured ratios of carbon-14 to carbon-12 correspond to ages of 7800, 8800, and 9000 years with uncertainties of +/- 600 years.
Ishikawa, Masayori; Nagase, Naomi; Matsuura, Taeko; Hiratsuka, Junichi; Suzuki, Ryusuke; Miyamoto, Naoki; Sutherland, Kenneth Lee; Fujita, Katsuhisa; Shirato, Hiroki
2015-01-01
Abstract The scintillator with optical fiber (SOF) dosimeter consists of a miniature scintillator mounted on the tip of an optical fiber. The scintillator of the current SOF dosimeter is a 1-mm diameter hemisphere. For a scintillation dosimeter coupled with an optical fiber, measurement accuracy is influenced by signals due to Cerenkov radiation in the optical fiber. We have implemented a spectral filtering technique for compensating for the Cerenkov radiation effect specifically for our plastic scintillator-based dosimeter, using a wavelength-separated counting method. A dichroic mirror was used for separating input light signals. Individual signal counting was performed for high- and low-wavelength light signals. To confirm the accuracy, measurements with various amounts of Cerenkov radiation were performed by changing the incident direction while keeping the Ir-192 source-to-dosimeter distance constant, resulting in a fluctuation of <5%. Optical fiber bending was also addressed; no bending effect was observed for our wavelength-separated SOF dosimeter. PMID:25618136
Petasis, Doros T; Hendrich, Michael P
2015-01-01
Electron paramagnetic resonance (EPR) spectroscopy has long been a primary method for characterization of paramagnetic centers in materials and biological complexes. Transition metals in biological complexes have valence d-orbitals that largely define the chemistry of the metal centers. EPR spectra are distinctive for metal type, oxidation state, protein environment, substrates, and inhibitors. The study of many metal centers in proteins, enzymes, and biomimetic complexes has led to the development of a systematic methodology for quantitative interpretation of EPR spectra from a wide array of metal containing complexes. The methodology is now contained in the computer program SpinCount. SpinCount allows simulation of EPR spectra from any sample containing multiple species composed of one or two metals in any spin state. The simulations are quantitative, thus allowing determination of all species concentrations in a sample directly from spectra. This chapter will focus on applications to transition metals in biological systems using EPR spectra from multiple microwave frequencies and modes. © 2015 Elsevier Inc. All rights reserved.
The impact of shrimp farming effluent on bacterial communities in mangrove waters, Ceará, Brazil.
Sousa, O V; Macrae, A; Menezes, F G R; Gomes, N C M; Vieira, R H S F; Mendonça-Hagler, L C S
2006-12-01
The effects of shrimp farm effluents on bacterial communities in mangroves have been infrequently reported. Classic and molecular biology methods were used to survey bacterial communities from four mangroves systems. Water temperature, salinity, pH, total heterotrophic bacteria and maximum probable numbers of Vibrio spp. were investigated. Genetic profiles of bacterial communities were also characterized by polymerase chain reaction (PCR) amplification of eubacterial and Vibrio 16S rDNA using denaturing gradient gel electrophoresis (DGGE). Highest heterotrophic counts were registered in the mangrove not directly polluted by shrimp farming. The Enterobacteriaceae and Chryseomonas luteola dominated the heterotrophic isolates. Vibrio spp. pathogenic to humans and shrimps were identified. Eubacterial genetic profiles suggest a shared community structure independent of mangrove system. Vibrio genetic profiles were mangrove specific. Neither microbial counts nor genetic profiling revealed a significant decrease in species richness associated with shrimp farm effluent. The complex nature of mangrove ecosystems and their microbial communities is discussed.
Monitoring trends in bird populations: addressing background levels of annual variability in counts
Jared Verner; Kathryn L. Purcell; Jennifer G. Turner
1996-01-01
Point counting has been widely accepted as a method for monitoring trends in bird populations. Using a rigorously standardized protocol at 210 counting stations at the San Joaquin Experimental Range, Madera Co., California, we have been studying sources of variability in point counts of birds. Vegetation types in the study area have not changed during the 11 years of...
Pill counts and pill rental: unintended entrepreneurial opportunities.
Viscomi, Christopher M; Covington, Melissa; Christenson, Catherine
2013-07-01
Prescription opioid diversion and abuse are becoming increasingly prevalent in many regions of the world, particularly the United States. One method advocated to assess compliance with opioid prescriptions is occasional "pill counts." Shortly before a scheduled appointment, a patient is notified that they must bring in the unused portion of their opioid prescription. It has been assumed that if a patient has the correct number and strength of pills that should be present for that point in a prescription interval that they are unlikely to be selling or abusing their opioids. Two cases are presented where patients describe short term rental of opioids from illicit opioid dealers in order to circumvent pill counts. Pill renting appears to be an established method of circumventing pill counts. Pill counts do not assure non-diversion of opioids and provide additional cash flow to illicit opioid dealers.
The Foraging Ecology of Royal and Sandwich Terns in North Carolina, USA
McGinnis, T.W.; Emslie, S.D.
2001-01-01
Population sizes of territorial male red-winged blackbirds (Agelaius phoeniceus) were determined with counts of territorial males (area count) and a Petersen-Lincoln Index method for roadsides (roadside estimate). Weather conditions and time of day did not influence either method. Combined roadside estimates had smaller error bounds than the individual transect estimates and were not hindered by the problem of zero recaptures. Roadside estimates were usually one-half as large as the area counts, presumably due to an observer bias for marked birds. The roadside estimate provides only an index of major changes in populations of territorial male redwings. When the roadside estimate is employed, the area count should be used to determine the amount and nature of observer bias. For small population surveys, the area count is probably more reliable and accurate than the roadside estimate.
Determining population size of territorial red-winged blackbirds
Albers, P.H.
1976-01-01
Population sizes of territorial male red-winged blackbirds (Agelaius phoeniceus) were determined with counts of territorial males (area count) and a Petersen-Lincoln Index method for roadsides (roadside estimate). Weather conditions and time of day did not influence either method. Combined roadside estimates had smaller error bounds than the individual transect estimates and were not hindered by the problem of zero recaptures. Roadside estimates were usually one-half as large as the area counts, presumably due to an observer bias for marked birds. The roadside estimate provides only an index of major changes in populations of territorial male redwings. When the roadside estimate is employed, the area count should be used to determine the amount and nature of observer bias. For small population surveys, the area count is probably more reliable and accurate than the roadside estimate.
Can Detectability Analysis Improve the Utility of Point Counts for Temperate Forest Raptors?
Temperate forest breeding raptors are poorly represented in typical point count surveys because these birds are cryptic and typically breed at low densities. In recent years, many new methods for estimating detectability during point counts have been developed, including distanc...
Lindqvist, R
2006-07-01
Turbidity methods offer possibilities for generating data required for addressing microorganism variability in risk modeling given that the results of these methods correspond to those of viable count methods. The objectives of this study were to identify the best approach for determining growth parameters based on turbidity data and use of a Bioscreen instrument and to characterize variability in growth parameters of 34 Staphylococcus aureus strains of different biotypes isolated from broiler carcasses. Growth parameters were estimated by fitting primary growth models to turbidity growth curves or to detection times of serially diluted cultures either directly or by using an analysis of variance (ANOVA) approach. The maximum specific growth rates in chicken broth at 17 degrees C estimated by time to detection methods were in good agreement with viable count estimates, whereas growth models (exponential and Richards) underestimated growth rates. Time to detection methods were selected for strain characterization. The variation of growth parameters among strains was best described by either the logistic or lognormal distribution, but definitive conclusions require a larger data set. The distribution of the physiological state parameter ranged from 0.01 to 0.92 and was not significantly different from a normal distribution. Strain variability was important, and the coefficient of variation of growth parameters was up to six times larger among strains than within strains. It is suggested to apply a time to detection (ANOVA) approach using turbidity measurements for convenient and accurate estimation of growth parameters. The results emphasize the need to consider implications of strain variability for predictive modeling and risk assessment.
Radioisotope Dating with Accelerators.
ERIC Educational Resources Information Center
Muller, Richard A.
1979-01-01
Explains a new method of detecting radioactive isotopes by counting their accelerated ions rather than the atoms that decay during the counting period. This method increases the sensitivity by several orders of magnitude, and allows one to find the ages of much older and smaller samples. (GA)
NASA Astrophysics Data System (ADS)
Becchio, Cristina; Koul, Atesh; Ansuini, Caterina; Bertone, Cesare; Cavallo, Andrea
2018-03-01
Is it possible to directly perceive others' mental states? Mediating the debate between Direct Perception and Inferentialism proponents would require knowing "what counts as an inference and how to tell the difference between inferential and non-inferential processing" [1]. However, few theorists have even attempted to answer the question of what counts as inference. The consequence, as noted by Spaulding [1], is that "given that neither Inferentialists nor DSP [Direct Social Perception, Ed.] proponents specify what they mean by inference, it is hard to tell what exactly each side is affirming and denying. Thus, the debate between Inferentialism and DSP is at an impasse". Similar considerations apply to distinguishing between what is 'observable' versus 'unobservable' [2].
Simulated fissioning of uranium and testing of the fission-track dating method
McGee, V.E.; Johnson, N.M.; Naeser, C.W.
1985-01-01
A computer program (FTD-SIM) faithfully simulates the fissioning of 238U with time and 235U with neutron dose. The simulation is based on first principles of physics where the fissioning of 238U with the flux of time is described by Ns = ??f 238Ut and the fissioning of 235U with the fluence of neutrons is described by Ni = ??235U??. The Poisson law is used to set the stochastic variation of fissioning within the uranium population. The life history of a given crystal can thus be traced under an infinite variety of age and irradiation conditions. A single dating attempt or up to 500 dating attempts on a given crystal population can be simulated by specifying the age of the crystal population, the size and variation in the areas to be counted, the amount and distribution of uranium, the neutron dose to be used and its variation, and the desired ratio of 238U to 235U. A variety of probability distributions can be applied to uranium and counting-area. The Price and Walker age equation is used to estimate age. The output of FTD-SIM includes the tabulated results of each individual dating attempt (sample) on demand and/or the summary statistics and histograms for multiple dating attempts (samples) including the sampling age. An analysis of the results from FTD-SIM shows that: (1) The external detector method is intrinsically more precise than the population method. (2) For the external detector method a correlation between spontaneous track count, Ns, and induced track count, Ni, results when the population of grains has a stochastic uranium content and/or when the counting areas between grains are stochastic. For the population method no correlation can exist. (3) In the external detector method the sampling distribution of age is independent of the number of grains counted. In the population method the sampling distribution of age is highly dependent on the number of grains counted. (4) Grains with zero-track counts, either in Ns or Ni, are in integral part of fissioning theory and under certain circumstances must be included in any estimate of age. (5) In estimating standard error of age the standard error of Ns and Ni and ?? must be accurately estimated and propagated through the age equation. Several statistical models are presently available to do so. ?? 1985.
Comparison of five techniques for the detection of Renibacterium salmoninarum in adult coho salmon.
Pascho, R.J.; Elliott, D.G.; Mallett, R.W.; Mulcahy, D.
1987-01-01
Samples of kidney, spleen, coelomic fluid, and blood from 56 sexually mature coho salmon Oncorhynchus kisutch were examined for infection by Renibacterium salmoninarum by five methods. The overall prevalence (all sample types combined) of R. salmoninarum in the fish was 100% by the enzyme-linked immunosorbent assay, 86% by the combined results of the direct fluorescent antibody and the direct filtration-fluorescent antibody techniques, 39% by culture, 11% by counterimmunoelectrophoresis, and 5% by agarose gel immunodiffusion. There was a significant positive correlation (P < 0.001) between the enzyme-linked immunosorbent assay absorbance levels and the counts by fluorescent antibody techniques for kidney, spleen, and coelomic fluid, and significant positive correlations (P < 0.001) in enzyme-linked immunosorbent assay absorbance levels for all four of the sample types.
Designing and implementing a monitoring program and the standards for conducting point counts
C. John Ralph
1993-01-01
Choosing between the apparent plethora of methods for monitoring bird populations is a dilemma for a person contemplating beginning a monitoring program. Cooperrider et al. (1986) and Koskimies and Vaisanen (1991) describe many methods. In the Americas, three methods have been suggested as standard (Butcher 1992). They are: point counts for determining habitat...
A variable circular-plot method for estimating bird numbers
R. T. Reynolds; J. M. Scott; R. A. Nussbaum
1980-01-01
A bird census method is presented that is designed for tall, structurally complex vegetation types, and rugged terrain. With this method the observer counts all birds seen or heard around a station, and estimates the horizontal distance from the station to each bird. Count periods at stations vary according to the avian community and structural complexity of the...
Unno, Y; Sanami, T; Sasaki, S; Hagiwara, M; Yunoki, A
2018-04-01
Absolute measurement by the 4πβ-γ coincidence counting method was conducted by two photomultipliers facing across a plastic scintillator to be focused on β ray counting efficiency. The detector was held with a through-hole-type NaI(Tl) detector. The results include absolutely determined activity and its uncertainty especially about extrapolation. A comparison between the obtained and known activities showed agreement within their uncertainties. Copyright © 2017 Elsevier Ltd. All rights reserved.
Deep 3 GHz number counts from a P(D) fluctuation analysis
NASA Astrophysics Data System (ADS)
Vernstrom, T.; Scott, Douglas; Wall, J. V.; Condon, J. J.; Cotton, W. D.; Fomalont, E. B.; Kellermann, K. I.; Miller, N.; Perley, R. A.
2014-05-01
Radio source counts constrain galaxy populations and evolution, as well as the global star formation history. However, there is considerable disagreement among the published 1.4-GHz source counts below 100 μJy. Here, we present a statistical method for estimating the μJy and even sub-μJy source count using new deep wide-band 3-GHz data in the Lockman Hole from the Karl G. Jansky Very Large Array. We analysed the confusion amplitude distribution P(D), which provides a fresh approach in the form of a more robust model, with a comprehensive error analysis. We tested this method on a large-scale simulation, incorporating clustering and finite source sizes. We discuss in detail our statistical methods for fitting using Markov chain Monte Carlo, handling correlations, and systematic errors from the use of wide-band radio interferometric data. We demonstrated that the source count can be constrained down to 50 nJy, a factor of 20 below the rms confusion. We found the differential source count near 10 μJy to have a slope of -1.7, decreasing to about -1.4 at fainter flux densities. At 3 GHz, the rms confusion in an 8-arcsec full width at half-maximum beam is ˜ 1.2 μJy beam-1, and a radio background temperature ˜14 mK. Our counts are broadly consistent with published evolutionary models. With these results, we were also able to constrain the peak of the Euclidean normalized differential source count of any possible new radio populations that would contribute to the cosmic radio background down to 50 nJy.
Hematology of healthy Florida manatees (Trichechus manatus)
Harvey, J.W.; Harr, K.E.; Murphy, D.; Walsh, M.T.; Nolan, E.C.; Bonde, R.K.; Pate, M.G.; Deutsch, C.J.; Edwards, H.H.; Clapp, W.L.
2009-01-01
Background: Hematologic analysis is an important tool in evaluating the general health status of free-ranging manatees and in the diagnosis and monitoring of rehabilitating animals. Objectives: The purpose of this study was to evaluate diagnostically important hematologic analytes in healthy manatees (Trichechus manatus) and to assess variations with respect to location (free ranging vs captive), age class (small calves, large calves, subadults, and adults), and gender. Methods: Blood was collected from 55 free-ranging and 63 captive healthy manatees. Most analytes were measured using a CELL-DYN 3500R; automated reticulocytes were measured with an ADVIA 120. Standard manual methods were used for differential leukocyte counts, reticulocyte and Heinz body counts, and plasma protein and fibrinogen concentrations. Results: Rouleaux, slight polychromasia, stomatocytosis, and low numbers of schistocytes and nucleated RBCs (NRBCs) were seen often in stained blood films. Manual reticulocyte counts were higher than automated reticulocyte counts. Heinz bodies were present in erythrocytes of most manatees. Compared with free-ranging manatees, captive animals had slightly lower MCV, MCH, and eosinophil counts and slightly higher heterophil and NRBC counts, and fibrinogen concentration. Total leukocyte, heterophil, and monocyte counts tended to be lower in adults than in younger animals. Small calves tended to have higher reticulocyte counts and NRBC counts than older animals. Conclusions: Hematologic findings were generally similar between captive and free-ranging manatees. Higher manual reticulocyte counts suggest the ADVIA detects only reticulocytes containing large amounts of RNA. Higher reticulocyte and NRBC counts in young calves probably reflect an increased rate of erythropoiesis compared with older animals. ?? 2009 American Society for Veterinary Clinical Pathology.
Orthogonal bases of invariants in tensor models
NASA Astrophysics Data System (ADS)
Diaz, Pablo; Rey, Soo-Jong
2018-02-01
Representation theory provides an efficient framework to count and classify invariants in tensor models of (gauge) symmetry G d = U( N 1) ⊗ · · · ⊗ U( N d ) . We show that there are two natural ways of counting invariants, one for arbitrary G d and another valid for large rank of G d . We construct basis of invariant operators based on the counting, and compute correlators of their elements. The basis associated with finite rank of G d diagonalizes two-point function. It is analogous to the restricted Schur basis used in matrix models. We comment on future directions for investigation.
Ayoade, Folusakin; Todd, John; Al-Delfi, Firas; King, John
2017-10-01
Toxoplasmosis is an important cause of enhancing brain lesions in patients with acquired immunodeficiency syndrome (AIDS), and it is typically associated with low CD4-lymphocyte counts. Extensive toxoplasma encephalitis when the CD4-lymphocyte count is above 100 cells/µl is unusual. Cavitary lung lesions are also not typically associated with toxoplasmosis. Here, we present a case of toxoplasmosis associated with extensive brain masses and cavitary lung lesions, both of which improved with directed toxoplasmosis therapy, in an AIDS patient with a CD4 cell count of 120 cells/µl.
Kubínová, Zuzana
2014-01-01
Chloroplast number per cell is a frequently examined quantitative anatomical parameter, often estimated by counting chloroplast profiles in two-dimensional (2D) sections of mesophyll cells. However, a mesophyll cell is a three-dimensional (3D) structure and this has to be taken into account when quantifying its internal structure. We compared 2D and 3D approaches to chloroplast counting from different points of view: (i) in practical measurements of mesophyll cells of Norway spruce needles, (ii) in a 3D model of a mesophyll cell with chloroplasts, and (iii) using a theoretical analysis. We applied, for the first time, the stereological method of an optical disector based on counting chloroplasts in stacks of spruce needle optical cross-sections acquired by confocal laser-scanning microscopy. This estimate was compared with counting chloroplast profiles in 2D sections from the same stacks of sections. Comparing practical measurements of mesophyll cells, calculations performed in a 3D model of a cell with chloroplasts as well as a theoretical analysis showed that the 2D approach yielded biased results, while the underestimation could be up to 10-fold. We proved that the frequently used method for counting chloroplasts in a mesophyll cell by counting their profiles in 2D sections did not give correct results. We concluded that the present disector method can be efficiently used for unbiased estimation of chloroplast number per mesophyll cell. This should be the method of choice, especially in coniferous needles and leaves with mesophyll cells with lignified cell walls where maceration methods are difficult or impossible to use. PMID:24336344
Predicting miRNA targets for head and neck squamous cell carcinoma using an ensemble method.
Gao, Hong; Jin, Hui; Li, Guijun
2018-01-01
This study aimed to uncover potential microRNA (miRNA) targets in head and neck squamous cell carcinoma (HNSCC) using an ensemble method which combined 3 different methods: Pearson's correlation coefficient (PCC), Lasso and a causal inference method (i.e., intervention calculus when the directed acyclic graph (DAG) is absent [IDA]), based on Borda count election. The Borda count election method was used to integrate the top 100 predicted targets of each miRNA generated by individual methods. Afterwards, to validate the performance ability of our method, we checked the TarBase v6.0, miRecords v2013, miRWalk v2.0 and miRTarBase v4.5 databases to validate predictions for miRNAs. Pathway enrichment analysis of target genes in the top 1,000 miRNA-messenger RNA (mRNA) interactions was conducted to focus on significant KEGG pathways. Finally, we extracted target genes based on occurrence frequency ≥3. Based on an absolute value of PCC >0.7, we found 33 miRNAs and 288 mRNAs for further analysis. We extracted 10 target genes with predicted frequencies not less than 3. The target gene MYO5C possessed the highest frequency, which was predicted by 7 different miRNAs. Significantly, a total of 8 pathways were identified; the pathways of cytokine-cytokine receptor interaction and chemokine signaling pathway were the most significant. We successfully predicted target genes and pathways for HNSCC relying on miRNA expression data, mRNA expression profile, an ensemble method and pathway information. Our results may offer new information for the diagnosis and estimation of the prognosis of HNSCC.
PHASE DIFFERENTIAL INDICATING CIRCUIT
Kirsten, F.A.
1962-01-01
An electronic circuit for totalizing the net phase difference between two alternating current signals is designed which responds to both increasing and decreasing phase changes. A phase comparator provldes an output pulse for each 360 deg of phase difference occurring, there being a negative pulse for phase shtft in one direction and a positive pulse for a phase shift in the opposite direction. A counting circuit utilizing glow discharge tubes receives the negative and positive pulses at a single input terminal and provides a running net total, pulses of one polarity dded and pulses of the opposite polarity being subtracted. The glow discharge tubes may be decaded to increase the total count capacity. (AEC)
Scoglio, M E; Di Pietro, A; Anzalone, C; Calimeri, S; Lo Giudice, D; Trimarchi, G R
2000-01-01
The toxicity of synthetic sewage containing increasing concentrations of arsenic (.125, .25, .5, 1.0 mg L-1), cadmium (.02, .05, .1, .2 mg L-1), lead (.2, .5, 1.0, 2.0 mg L-1) and nickel (.5, 1.0, 2.0, 4.0 mg L-1) has been investigated by determining the total direct count (TDC) and the direct viable count (DVC) of Salmonella enteritidis by means of an immunofluorescence technique (IFA). This has been done in order to evaluate the possibility of using the IFA technique to estimate the toxicity of complex effluents. Arsenic, cadmium and nickel produced a concentration-dependent reduction in the number of viable bacterial cells. This was more clear when the viable bacterial cells were considered than when only the culturable part was used. Lead did not show a concentration-dependent and reproducible effect. At the highest concentrations allowed by the Italian wastewater regulations, lead, cadmium, arsenic and nickel reduced the viable/total bacterial cells ratio to 74.5%, 68.5%, 28.4% and 6.9%, respectively. The toxic effects of the metals were also tested using the standard Microtox assay.
Counting Tree Growth Rings Moderately Difficult to Distinguish
C. B. Briscoe; M. Chudnoff
1964-01-01
There is an extensive literature dealing with techniques and gadgets to facilitate counting tree growth rings. A relatively simple method is described below, satisfactory for species too difficult to count in the field, but not sufficiently difficult to require the preparation of microscope slides nor staining techniques.
Andrade, N J; Bridgeman, T A; Zottola, E A
1998-07-01
Enterococcus faecium attached to stainless steel chips (100 mm2) was treated with the following sanitizers: sodium hypochlorite, peracetic acid (PA), peracetic acid plus an organic acid (PAS), quaternary ammonium, organic acid, and anionic acid. The effectiveness of sanitizer solutions on planktonic cells (not attached) was evaluated by the Association of Official Analytical Chemists (AOAC) suspension test. The number of attached cells was determined by impedance measurement and plate count method after vortexing. The decimal reduction (DR) in numbers of the E. faecium population was determined for the three methods and was analyzed by analysis of variance (P < 0.05) using Statview software. The adhered cells were more resistant (P < 0.05) than nonadherent cells. The DR averages for all of the sanitizers for 30 s of exposure were 6.4, 2.2, and 2.5 for the AOAC suspension test, plate count method after vortexing, and impedance measurement, respectively. Plate count and impedance methods showed a difference (P < 0.05) after 30 s of sanitizer exposure but not after 2 min. The impedance measurement was the best method to measure adherent cells. Impedance measurement required the development of a quadratic regression. The equation developed from 82 samples is as follows: log CFU/chip = 0.2385T2-0.96T + 9.35, r2 = 0.92, P < 0.05, T = impedance detection time in hours. This method showed that the sanitizers PAS and PA were more effective against E. faecium than the other sanitizers. At 30 s, the impedance method recovered about 25 times more cells than the plate count method after vortexing. These data suggest that impedance measurement is the method of choice when evaluating the number of bacterial cells adhered to a surface.
Anatomical-based partial volume correction for low-dose dedicated cardiac SPECT/CT
NASA Astrophysics Data System (ADS)
Liu, Hui; Chan, Chung; Grobshtein, Yariv; Ma, Tianyu; Liu, Yaqiang; Wang, Shi; Stacy, Mitchel R.; Sinusas, Albert J.; Liu, Chi
2015-09-01
Due to the limited spatial resolution, partial volume effect has been a major degrading factor on quantitative accuracy in emission tomography systems. This study aims to investigate the performance of several anatomical-based partial volume correction (PVC) methods for a dedicated cardiac SPECT/CT system (GE Discovery NM/CT 570c) with focused field-of-view over a clinically relevant range of high and low count levels for two different radiotracer distributions. These PVC methods include perturbation geometry transfer matrix (pGTM), pGTM followed by multi-target correction (MTC), pGTM with known concentration in blood pool, the former followed by MTC and our newly proposed methods, which perform the MTC method iteratively, where the mean values in all regions are estimated and updated by the MTC-corrected images each time in the iterative process. The NCAT phantom was simulated for cardiovascular imaging with 99mTc-tetrofosmin, a myocardial perfusion agent, and 99mTc-red blood cell (RBC), a pure intravascular imaging agent. Images were acquired at six different count levels to investigate the performance of PVC methods in both high and low count levels for low-dose applications. We performed two large animal in vivo cardiac imaging experiments following injection of 99mTc-RBC for evaluation of intramyocardial blood volume (IMBV). The simulation results showed our proposed iterative methods provide superior performance than other existing PVC methods in terms of image quality, quantitative accuracy, and reproducibility (standard deviation), particularly for low-count data. The iterative approaches are robust for both 99mTc-tetrofosmin perfusion imaging and 99mTc-RBC imaging of IMBV and blood pool activity even at low count levels. The animal study results indicated the effectiveness of PVC to correct the overestimation of IMBV due to blood pool contamination. In conclusion, the iterative PVC methods can achieve more accurate quantification, particularly for low count cardiac SPECT studies, typically obtained from low-dose protocols, gated studies, and dynamic applications.
Czakó, Gábor; Szalay, Viktor; Császár, Attila G
2006-01-07
The currently most efficient finite basis representation (FBR) method [Corey et al., in Numerical Grid Methods and Their Applications to Schrodinger Equation, NATO ASI Series C, edited by C. Cerjan (Kluwer Academic, New York, 1993), Vol. 412, p. 1; Bramley et al., J. Chem. Phys. 100, 6175 (1994)] designed specifically to deal with nondirect product bases of structures phi(n) (l)(s)f(l)(u), chi(m) (l)(t)phi(n) (l)(s)f(l)(u), etc., employs very special l-independent grids and results in a symmetric FBR. While highly efficient, this method is not general enough. For instance, it cannot deal with nondirect product bases of the above structure efficiently if the functions phi(n) (l)(s) [and/or chi(m) (l)(t)] are discrete variable representation (DVR) functions of the infinite type. The optimal-generalized FBR(DVR) method [V. Szalay, J. Chem. Phys. 105, 6940 (1996)] is designed to deal with general, i.e., direct and/or nondirect product, bases and grids. This robust method, however, is too general, and its direct application can result in inefficient computer codes [Czako et al., J. Chem. Phys. 122, 024101 (2005)]. It is shown here how the optimal-generalized FBR method can be simplified in the case of nondirect product bases of structures phi(n) (l)(s)f(l)(u), chi(m) (l)(t)phi(n) (l)(s)f(l)(u), etc. As a result the commonly used symmetric FBR is recovered and simplified nonsymmetric FBRs utilizing very special l-dependent grids are obtained. The nonsymmetric FBRs are more general than the symmetric FBR in that they can be employed efficiently even when the functions phi(n) (l)(s) [and/or chi(m) (l)(t)] are DVR functions of the infinite type. Arithmetic operation counts and a simple numerical example presented show unambiguously that setting up the Hamiltonian matrix requires significantly less computer time when using one of the proposed nonsymmetric FBRs than that in the symmetric FBR. Therefore, application of this nonsymmetric FBR is more efficient than that of the symmetric FBR when one wants to diagonalize the Hamiltonian matrix either by a direct or via a basis-set contraction method. Enormous decrease of computer time can be achieved, with respect to a direct application of the optimal-generalized FBR, by employing one of the simplified nonsymmetric FBRs as is demonstrated in noniterative calculations of the low-lying vibrational energy levels of the H3+ molecular ion. The arithmetic operation counts of the Hamiltonian matrix vector products and the properties of a recently developed diagonalization method [Andreozzi et al., J. Phys. A Math. Gen. 35, L61 (2002)] suggest that the nonsymmetric FBR applied along with this particular diagonalization method is suitable to large scale iterative calculations. Whether or not the nonsymmetric FBR is competitive with the symmetric FBR in large-scale iterative calculations still has to be investigated numerically.
Concurrent activation of striatal direct and indirect pathways during action initiation.
Cui, Guohong; Jun, Sang Beom; Jin, Xin; Pham, Michael D; Vogel, Steven S; Lovinger, David M; Costa, Rui M
2013-02-14
The basal ganglia are subcortical nuclei that control voluntary actions, and they are affected by a number of debilitating neurological disorders. The prevailing model of basal ganglia function proposes that two orthogonal projection circuits originating from distinct populations of spiny projection neurons (SPNs) in the striatum--the so-called direct and indirect pathways--have opposing effects on movement: activity of direct-pathway SPNs is thought to facilitate movement, whereas activity of indirect-pathway SPNs is presumed to inhibit movement. This model has been difficult to test owing to the lack of methods to selectively measure the activity of direct- and indirect-pathway SPNs in freely moving animals. Here we develop a novel in vivo method to specifically measure direct- and indirect-pathway SPN activity, using Cre-dependent viral expression of the genetically encoded calcium indicator (GECI) GCaMP3 in the dorsal striatum of D1-Cre (direct-pathway-specific) and A2A-Cre (indirect-pathway-specific) mice. Using fibre optics and time-correlated single-photon counting (TCSPC) in mice performing an operant task, we observed transient increases in neural activity in both direct- and indirect-pathway SPNs when animals initiated actions, but not when they were inactive. Concurrent activation of SPNs from both pathways in one hemisphere preceded the initiation of contraversive movements and predicted the occurrence of specific movements within 500 ms. These observations challenge the classical view of basal ganglia function and may have implications for understanding the origin of motor symptoms in basal ganglia disorders.
A comparison of cosegregation analysis methods for the clinical setting.
Rañola, John Michael O; Liu, Quanhui; Rosenthal, Elisabeth A; Shirts, Brian H
2018-04-01
Quantitative cosegregation analysis can help evaluate the pathogenicity of genetic variants. However, genetics professionals without statistical training often use simple methods, reporting only qualitative findings. We evaluate the potential utility of quantitative cosegregation in the clinical setting by comparing three methods. One thousand pedigrees each were simulated for benign and pathogenic variants in BRCA1 and MLH1 using United States historical demographic data to produce pedigrees similar to those seen in the clinic. These pedigrees were analyzed using two robust methods, full likelihood Bayes factors (FLB) and cosegregation likelihood ratios (CSLR), and a simpler method, counting meioses. Both FLB and CSLR outperform counting meioses when dealing with pathogenic variants, though counting meioses is not far behind. For benign variants, FLB and CSLR greatly outperform as counting meioses is unable to generate evidence for benign variants. Comparing FLB and CSLR, we find that the two methods perform similarly, indicating that quantitative results from either of these methods could be combined in multifactorial calculations. Combining quantitative information will be important as isolated use of cosegregation in single families will yield classification for less than 1% of variants. To encourage wider use of robust cosegregation analysis, we present a website ( http://www.analyze.myvariant.org ) which implements the CSLR, FLB, and Counting Meioses methods for ATM, BRCA1, BRCA2, CHEK2, MEN1, MLH1, MSH2, MSH6, and PMS2. We also present an R package, CoSeg, which performs the CSLR analysis on any gene with user supplied parameters. Future variant classification guidelines should allow nuanced inclusion of cosegregation evidence against pathogenicity.
Evaluation of counting methods for oceanic radium-228
NASA Astrophysics Data System (ADS)
Orr, James C.
1988-07-01
Measurement of open ocean 228Ra is difficult, typically requiring at least 200 L of seawater. The burden of collecting and processing these large-volume samples severely limits the widespread use of this promising tracer. To use smaller-volume samples, a more sensitive means of analysis is required. To seek out new and improved counting method(s), conventional 228Ra counting methods have been compared with some promising techniques which are currently used for other radionuclides. Of the conventional methods, α spectrometry possesses the highest efficiency (3-9%) and lowest background (0.0015 cpm), but it suffers from the need for complex chemical processing after sampling and the need to allow about 1 year for adequate ingrowth of 228Th granddaughter. The other two conventional counting methods measure the short-lived 228Ac daughter while it remains supported by 228Ra, thereby avoiding the complex sample processing and the long delay before counting. The first of these, high-resolution γ spectrometry, offers the simplest processing and an efficiency (4.8%) comparable to α spectrometry; yet its high background (0.16 cpm) and substantial equipment cost (˜30,000) limit its widespread use. The second no-wait method, β-γ coincidence spectrometry, also offers comparable efficiency (5.3%), but it possesses both lower background (0.0054 cpm) and lower initial cost (˜12,000). Three new (i.e., untried for 228Ra) techniques all seem to promise about a fivefold increase in efficiency over conventional methods. By employing liquid scintillation methods, both α spectrometry and β-γ coincidence spectrometry can improve their counter efficiency while retaining low background. The third new 228Ra counting method could be adapted from a technique which measures 224Ra by 220Rn emanation. After allowing for ingrowth and then counting for the 224Ra great-granddaughter, 228Ra could be back calculated, thereby yielding a method with high efficiency, where no sample processing is required. The efficiency and background of each of the three new methods have been estimated and are compared with those of the three methods currently employed to measure oceanic 228Ra. From efficiency and background, the relative figure of merit and the detection limit have been determined for each of the six counters. These data suggest that the new counting methods have the potential to measure most 228Ra samples with just 30 L of seawater, to better than 5% precision. Not only would this reduce the time, effort, and expense involved in sample collection, but 228Ra could then be measured on many small-volume samples (20-30 L) previously collected with only 226Ra in mind. By measuring 228Ra quantitatively on such small-volume samples, three analyses (large-volume 228Ra, large-volume 226Ra, and small-volume 226Ra) could be reduced to one, thereby dramatically improving analytical precision.
Englehardt, James D; Ashbolt, Nicholas J; Loewenstine, Chad; Gadzinski, Erik R; Ayenu-Prah, Albert Y
2012-06-01
Recently pathogen counts in drinking and source waters were shown theoretically to have the discrete Weibull (DW) or closely related discrete growth distribution (DGD). The result was demonstrated versus nine short-term and three simulated long-term water quality datasets. These distributions are highly skewed such that available datasets seldom represent the rare but important high-count events, making estimation of the long-term mean difficult. In the current work the methods, and data record length, required to assess long-term mean microbial count were evaluated by simulation of representative DW and DGD waterborne pathogen count distributions. Also, microbial count data were analyzed spectrally for correlation and cycles. In general, longer data records were required for more highly skewed distributions, conceptually associated with more highly treated water. In particular, 500-1,000 random samples were required for reliable assessment of the population mean ±10%, though 50-100 samples produced an estimate within one log (45%) below. A simple correlated first order model was shown to produce count series with 1/f signal, and such periodicity over many scales was shown in empirical microbial count data, for consideration in sampling. A tiered management strategy is recommended, including a plan for rapid response to unusual levels of routinely-monitored water quality indicators.
WFIRST: Predicting the number density of Hα-emitting galaxies
NASA Astrophysics Data System (ADS)
Benson, Andrew; Merson, Alex; Wang, Yun; Faisst, Andreas; Masters, Daniel; Kiessling, Alina; Rhodes, Jason
2018-01-01
The WFIRST mission will measure the clustering of Hα-emitting galaxies to help probe the nature of dark energy. Knowledge of the number density of such galaxies is therefore vital for forecasting the precision of thesemeasurements and assessing the scientific impact of the WFIRST mission. In this poster we present predictions from a galaxy formation model, Galacticus, for the cumulative number counts of Hα-emitting galaxies. We couple Galacticus to three different dust attenuation methods and examine the counts using each method. A χ2 minimization approach is used to compare the model counts to observed galaxy counts and calibrate the dust parameters. With these calibrated dust methods, we find that the Hα luminosity function from Galacticus is broadly consistent with observed estimates. Finally we present forecasts for the redshift distributions and number counts for a WFIRST-like survey. We predict that over a redshift range of 1 ≤ z ≤ 2 and with a blended flux limit of 1×10-16 erg s-1cm-2 Galacticus predicts that WFIRST would expect to observe a number density between 10400-15200 Hα-emitting galaxies per square degree.
Usefulness of hemocytometer as a counting chamber in a computer assisted sperm analyzer (CASA)
Eljarah, A.; Chandler, J.; Jenkins, J.A.; Chenevert, J.; Alcanal, A.
2013-01-01
Several methods are used to determine sperm cell concentration, such as the haemocytometer, spectrophotometer, electronic cell counter and computer-assisted semen analysers (CASA). The utility of CASA systems has been limited due to the lack of characterization of individual systems and the absence of standardization among laboratories. The aims of this study were to: 1) validate and establish setup conditions for the CASA system utilizing the haemocytometer as a counting chamber, and 2) compare the different methods used for the determination of sperm cell concentration in bull semen. Two ejaculates were collected and the sperm cell concentration was determined using spectrophotometer and haemocytometer. For the Hamilton-Thorn method, the haemocytometer was used as a counting chamber. Sperm concentration was determined three times per ejaculate samples. A difference (P 0.05) or between the haemocytometer count and the spectrophotometer. Based on the results of this study, we concluded that the haemocytometer can be used in computerized semen analysis systems as a substitute for the commercially available disposable counting chambers, therefore avoiding disadvantageous high costs and slower procedures.
Determination of fetal DNA fraction from the plasma of pregnant women using sequence read counts.
Kim, Sung K; Hannum, Gregory; Geis, Jennifer; Tynan, John; Hogg, Grant; Zhao, Chen; Jensen, Taylor J; Mazloom, Amin R; Oeth, Paul; Ehrich, Mathias; van den Boom, Dirk; Deciu, Cosmin
2015-08-01
This study introduces a novel method, referred to as SeqFF, for estimating the fetal DNA fraction in the plasma of pregnant women and to infer the underlying mechanism that allows for such statistical modeling. Autosomal regional read counts from whole-genome massively parallel single-end sequencing of circulating cell-free DNA (ccfDNA) from the plasma of 25 312 pregnant women were used to train a multivariate model. The pretrained model was then applied to 505 pregnant samples to assess the performance of SeqFF against known methodologies for fetal DNA fraction calculations. Pearson's correlation between chromosome Y and SeqFF for pregnancies with male fetuses from two independent cohorts ranged from 0.932 to 0.938. Comparison between a single-nucleotide polymorphism-based approach and SeqFF yielded a Pearson's correlation of 0.921. Paired-end sequencing suggests that shorter ccfDNA, that is, less than 150 bp in length, is nonuniformly distributed across the genome. Regions exhibiting an increased proportion of short ccfDNA, which are more likely of fetal origin, tend to provide more information in the SeqFF calculations. SeqFF is a robust and direct method to determine fetal DNA fraction. Furthermore, the method is applicable to both male and female pregnancies and can greatly improve the accuracy of noninvasive prenatal testing for fetal copy number variation. © 2015 John Wiley & Sons, Ltd.
Ripple, Dean C; Montgomery, Christopher B; Hu, Zhishang
2015-02-01
Accurate counting and sizing of protein particles has been limited by discrepancies of counts obtained by different methods. To understand the bias and repeatability of techniques in common use in the biopharmaceutical community, the National Institute of Standards and Technology has conducted an interlaboratory comparison for sizing and counting subvisible particles from 1 to 25 μm. Twenty-three laboratories from industry, government, and academic institutions participated. The circulated samples consisted of a polydisperse suspension of abraded ethylene tetrafluoroethylene particles, which closely mimic the optical contrast and morphology of protein particles. For restricted data sets, agreement between data sets was reasonably good: relative standard deviations (RSDs) of approximately 25% for light obscuration counts with lower diameter limits from 1 to 5 μm, and approximately 30% for flow imaging with specified manufacturer and instrument setting. RSDs of the reported counts for unrestricted data sets were approximately 50% for both light obscuration and flow imaging. Differences between instrument manufacturers were not statistically significant for light obscuration but were significant for flow imaging. We also report a method for accounting for differences in the reported diameter for flow imaging and electrical sensing zone techniques; the method worked well for diameters greater than 15 μm. © 2014 Wiley Periodicals, Inc. and the American Pharmacists Association.